WorldWideScience

Sample records for stereotactic heavy-charged-particle radiosurgery

  1. Stereotactic radiosurgery. The role of charged particles

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R.P.; Schulte, R.W.M.; Slater, J.D.; Miller, D.W.; Slater, J.M. [Loma Linda Univ. Medical Center, CA (United States). Dept. of Radiation Medicine

    1999-08-01

    Stereotactic radiosurgery using charged-particle beams has been the subject of biomedical research and clinical development for more than 50 years. Charged particles of proton mass or greater manifest unique physical properties that can be used to place a high dose of radiation preferentially within the boundaries of a deeply located intracranial target volume. Since 1954, nearly 10 000 patients have been treated using this technique. Treated disorders include pituitary tumors, vascular malformations, primary and metastatic brain tumors, and subfoveal neovascularization. Charged-particle radiosurgery is particularly advantageous for the conformal treatment of large and/or irregularly shaped lesions, or for the treatment of lesions located in front of or adjacent to sensitive brain structures. (orig.)

  2. Stereotactic radiosurgery. The role of charged particles

    International Nuclear Information System (INIS)

    Levy, R.P.; Schulte, R.W.M.; Slater, J.D.; Miller, D.W.; Slater, J.M.

    1999-01-01

    Stereotactic radiosurgery using charged-particle beams has been the subject of biomedical research and clinical development for more than 50 years. Charged particles of proton mass or greater manifest unique physical properties that can be used to place a high dose of radiation preferentially within the boundaries of a deeply located intracranial target volume. Since 1954, nearly 10 000 patients have been treated using this technique. Treated disorders include pituitary tumors, vascular malformations, primary and metastatic brain tumors, and subfoveal neovascularization. Charged-particle radiosurgery is particularly advantageous for the conformal treatment of large and/or irregularly shaped lesions, or for the treatment of lesions located in front of or adjacent to sensitive brain structures. (orig.)

  3. Clinical results of stereotactic heavy-charged-particle radiosurgery for intracranial angiographically occult vascular malformations

    International Nuclear Information System (INIS)

    Levy, R.P.; Fabrikant, J.I.; Phillips, M.H.; Frankel, K.A.; Steinberg, G.K.; Marks, M.P.; DeLaPaz, R.L.; Chuang, F.Y.S.; Lyman, J.T.

    1989-12-01

    Angiographically occult vascular malformations (AOVMs) of the brain have been recognized for many years to cause neurologic morbidity and mortality. They generally become symptomatic due to intracranial hemorrhage, focal mass effect, seizures or headaches. The true incidence of AOVMs is unknown, but autopsy studies suggest that they are more common than high-flow angiographically demonstrable arteriovenous malformations (AVMs). We have developed stereotactic heavy-charged-particle Bragg peak radiosurgery for the treatment of inoperable intracranial vascular malformations, using the helium ion beams at the Lawrence Berkeley Laboratory 184-inch Synchrocyclotron and Bevatron. This report describes the protocol for patient selection, radiosurgical treatment planning method, clinical and neuroradiologic results and complications encountered, and discusses the strengths and limitations of the method. 10 refs., 1 fig

  4. Clinical results of stereotactic heavy-charged-particle radiosurgery for intracranial angiographically occult vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R.P.; Fabrikant, J.I.; Phillips, M.H.; Frankel, K.A.; Steinberg, G.K.; Marks, M.P.; DeLaPaz, R.L.; Chuang, F.Y.S.; Lyman, J.T.

    1989-12-01

    Angiographically occult vascular malformations (AOVMs) of the brain have been recognized for many years to cause neurologic morbidity and mortality. They generally become symptomatic due to intracranial hemorrhage, focal mass effect, seizures or headaches. The true incidence of AOVMs is unknown, but autopsy studies suggest that they are more common than high-flow angiographically demonstrable arteriovenous malformations (AVMs). We have developed stereotactic heavy-charged-particle Bragg peak radiosurgery for the treatment of inoperable intracranial vascular malformations, using the helium ion beams at the Lawrence Berkeley Laboratory 184-inch Synchrocyclotron and Bevatron. This report describes the protocol for patient selection, radiosurgical treatment planning method, clinical and neuroradiologic results and complications encountered, and discusses the strengths and limitations of the method. 10 refs., 1 fig.

  5. Stereotactic helium-ion radiosurgery for the treatment of intracranial arteriovenous malformations

    International Nuclear Information System (INIS)

    Fabrikant, J.I.; Levy, R.P.; Frankel, K.A.; Phillips, M.H.; Lyman, J.T.; Chuang, F.Y.S.; Steinberg, G.K.; Marks, M.P.

    1989-12-01

    One of the more challenging problems of vascular neurosurgery is the management of surgically-inaccessible arteriovenous malformations (AVMs) of the brain. At Lawrence Berkeley Laboratory, we have developed the method of stereotactic heavy-charged-particle (helium-ion) Bragg peak radiosurgery for treatment of inoperable intracranial AVMs in over 300 patients since 1980 [Fabrikant et al. 1989, Fabrikant et al. 1985, Levy et al. 1989]. This report describes patient selection, treatment method, clinical and neuroradiologic results and complications encountered. 4 refs

  6. Clinical-radiological evaluation of sequelae of stereotactic radiosurgery for intracranial arteriovenous malformations

    International Nuclear Information System (INIS)

    Levy, R.P.; Fabrikant, J.I.; Frankel, K.A.; Phillips, M.H.; Steinberg, G.K.; Marks, M.P.; DeLaPaz, R.L.; Chuang, F.Y.S.

    1989-12-01

    Stereotactic heavy-charged-particle Bragg peak radiosurgery has been used to treat 322 patients with surgically-inaccessible intracranial vascular malformations. (The clinical results of this method for the treatment of angiographically demonstrable arteriovenous malformations (AVMs) and angiographically occult vascular malformations (AOVMs) of the brain are described in separate reports of this symposium). The great majority of patients have had an uneventful post-treatment course with satisfactory health outcomes. However, several categories of delayed sequelae of stereotactic radiosurgery have been identified, involving the vascular structures essential for the integrity of the brain tissue and the brain parenchyma directly. These categories reflect both reaction to injury and to alterations in regional hemodynamic status, and include vasogenic edema, occlusion of functional vasculature, radiation necrosis, and local or remote effects on cerebral arterial aneurysms. 10 refs., 7 figs., 1 tab

  7. Clinical-radiological evaluation of sequelae of stereotactic radiosurgery for intracranial arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R.P.; Fabrikant, J.I.; Frankel, K.A.; Phillips, M.H.; Steinberg, G.K.; Marks, M.P.; DeLaPaz, R.L.; Chuang, F.Y.S.

    1989-12-01

    Stereotactic heavy-charged-particle Bragg peak radiosurgery has been used to treat 322 patients with surgically-inaccessible intracranial vascular malformations. (The clinical results of this method for the treatment of angiographically demonstrable arteriovenous malformations (AVMs) and angiographically occult vascular malformations (AOVMs) of the brain are described in separate reports of this symposium). The great majority of patients have had an uneventful post-treatment course with satisfactory health outcomes. However, several categories of delayed sequelae of stereotactic radiosurgery have been identified, involving the vascular structures essential for the integrity of the brain tissue and the brain parenchyma directly. These categories reflect both reaction to injury and to alterations in regional hemodynamic status, and include vasogenic edema, occlusion of functional vasculature, radiation necrosis, and local or remote effects on cerebral arterial aneurysms. 10 refs., 7 figs., 1 tab.

  8. Patients burden in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Kralik, G.; Fribertova, M.; Trosanova, D.; Kolarcikova, E.

    2009-01-01

    Radiosurgery is one time application of High radiation to a stereotactically defined volume. Treatment delivery involves multiple stereotactically targeted, arced fields. The goal of Radiosurgery is to deliver a high dose to target, while only a minimum dose is delivered to adjacent normal tissue that are just a few millimeters away . Stereotactic Radiosurgery on linac has been employed at St. Elisabeth Cancer Institute in Bratislava since 1993. Until July 31,2008, 1 030 subjects have been treated including patients with brain tumors, metastases, recurrent tumours, and A V malformations, using Leibinger stereotaxy collimators or Mimic MLC system on a Linac accelerator. The presentation shows dose delivery to risk organs in different indications. (authors)

  9. The history of stereotactic radiosurgery and radiotherapy.

    Science.gov (United States)

    Lasak, John M; Gorecki, John P

    2009-08-01

    Stereotactic neurosurgery originated from the pioneering work of Horsley and Clarke, who developed a stereotactic apparatus to study the monkey brain in 1908. Spiegel and Wycis applied this technology to the human brain in 1947, which ultimately lead to the development of multiple stereotactic neurosurgical devices during the 1950s. It was Lars Leksell of Sweden, however, who envisioned stereotactic radiosurgery. Leksell developed the gamma knife to treat intracranial lesions in a noninvasive fashion. His work stimulated worldwide interest and created the field of stereotactic radiosurgery.

  10. Value of stereotactic radiosurgery in patients with multiple brain metastases

    International Nuclear Information System (INIS)

    Chen Jie; Lin Zhiguo; Li Qingguo; Shen Hong

    2002-01-01

    Objective: To analyze the prognostic factors and evaluate the effect of stereotactic radiosurgery for patients with multiple brain metastases. Methods: Comparison was made in 53 such patients treated by stereotactic radiosurgery plus radiotherapy and 53 treated by radiotherapy alone. Patients were matched-paired according to the following criteria: age, Karnofsky performance scale (KPS) before treatment, extent of systemic cancer and number of brain metastasis. Forty patients had stereotactic radiosurgery, 13 patients stereotactic fractionated radiosurgery. In the stereotactic radiosurgery group, the patients were given a mean marginal dose of 20 Gy. Methods of stereotactic fractionated radiosurgery was 4-12 Gy per fraction , twice a week to a total dose of 15-30 Gy. Whole brain radiotherapy was given immediately after stereotactic radiosurgery. For patients treated by radiotherapy alone, the entire brain was treated by 30-40 Gy in 3-4 weeks. Results: The median survival was 11.6 months in stereotactic radiosurgery plus radiotherapy and 6.7 months in radiotherapy alone. The one year survival rate and one year local control rate were 44.3%, 17.1% and 50.9%, 13. 2%. Those with KPS increased after treatment gave 1-year survivals of 69.8% and 30.2%, respectively. The validity rates in CT or MRI three months after treatment were 82.0% and 55.0%. The difference in the two groups was found to be statistically significant (P < 0.01). 23.3% of death in the stereotactic radiosurgery plus radiotherapy group was due to brain metastasis vs 51.0% in the radiotherapy alone group (P < 0.05). Complication of the two groups was similar. Conclusion: Stereotactic radiosurgery plus radiotherapy is superior to radiotherapy alone for multiple brain metastases in improving the local control and ultimate outcome

  11. Stereotactic radiosurgery using the gamma knife

    Energy Technology Data Exchange (ETDEWEB)

    Kawamoto, Shunsuke; Sasaki, Tomio; Matsutani, Masao; Takakura, Kintomo; Terahara, Atsuro (Tokyo Univ. (Japan). Faculty of Medicine)

    1992-03-01

    Since stereotactic radiosurgery using a gamma knife was developed in 1968 by Leksell, it has been used with increasing frequency in Japan. During the period from June 19, 1990 through December 20, 1991, 218 patients have been treated with stereotactic radiosurgery using a gamma knife. Of them, 116 had vascular lesions (116), including arteriovenous malformation (114), dural arteriovenous malformation (one), and cerebral aneurysm (one); and the other 102 had tumorous lesions, including acoustic neurinoma (48), meningioma (26), pituitary tumor (11), metastatic tumor (7), germ cell tumor (3), glioma (2), hemangioblastoma (2), chordoma (one), craniopharyngioma (one), and trigeminal neurinoma (one). In this article, candidates of stereotactic radiosurgery using a gamma knife are discussed, with particular attention to clinical results of the aforementioned 218 patients. (N.K.) 54 refs.

  12. Clinical results of stereotactic hellium-ion radiosurgery of the pituitary gland at Lawrence Berkeley Laboratory

    International Nuclear Information System (INIS)

    Levy, R.P.; Fabrikant, J.I.; Lyman, J.T.; Frankel, K.A.; Phillips, M.H.; Lawrence, J.H.; Tobias, C.A.

    1989-12-01

    The first therapeutic clinical trial using accelerated heavy-charged particles in humans was performed at Lawrence Berkeley Laboratory (LBL) for the treatment of various endocrine and metabolic disorders of the pituitary gland, and as suppressive therapy for adenohypophyseal hormone-responsive carcinomas and diabetic retinopathy. In acromegaly, Cushing's disease, Nelson's syndrome and prolactin-secreting tumors, the therapeutic goal in the 433 patients treated has been to destroy or inhibit the growth of the pituitary tumor and control hormonal hypersecretion, while preserving a functional rim of tissue with normal hormone-secreting capacity, and minimizing neurologic injury. An additional group of 34 patients was treated for nonsecreting chromophobe adenomas. This paper discusses the methods and results of stereotactic helium-ion radiosurgery of the pituitary gland at Lawrence Berkeley Laboratory. 11 refs

  13. Clinical results of stereotactic hellium-ion radiosurgery of the pituitary gland at Lawrence Berkeley Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R.P.; Fabrikant, J.I.; Lyman, J.T.; Frankel, K.A.; Phillips, M.H.; Lawrence, J.H.; Tobias, C.A.

    1989-12-01

    The first therapeutic clinical trial using accelerated heavy-charged particles in humans was performed at Lawrence Berkeley Laboratory (LBL) for the treatment of various endocrine and metabolic disorders of the pituitary gland, and as suppressive therapy for adenohypophyseal hormone-responsive carcinomas and diabetic retinopathy. In acromegaly, Cushing's disease, Nelson's syndrome and prolactin-secreting tumors, the therapeutic goal in the 433 patients treated has been to destroy or inhibit the growth of the pituitary tumor and control hormonal hypersecretion, while preserving a functional rim of tissue with normal hormone-secreting capacity, and minimizing neurologic injury. An additional group of 34 patients was treated for nonsecreting chromophobe adenomas. This paper discusses the methods and results of stereotactic helium-ion radiosurgery of the pituitary gland at Lawrence Berkeley Laboratory. 11 refs.

  14. Stereotactic radiosurgery: incision less surgery

    International Nuclear Information System (INIS)

    Alvarez, Victor M.; Palma, Raul B.

    1997-01-01

    Stereotactic Radiosurgery (SRS) involves the application of focused high dose, high energy radiation to precisely (stereotactically) localized targets in the head without opening the skull for the purpose of destroying pathologic tissues like tumors, and also for producing discrete lesions for the relief of certain functional disorders. This procedure was pioneered by Lars Leksel in the 1950s and has progressively been refined with the development of more powerful computer technology and more precise and safer radiation delivery systems. The used of the Linear Accelerator (LINAC)- based radiosurgery system would be the most cost-effective and appropriate system for this treatment

  15. Linac based radiosurgery and stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Mackie, T.R.

    2008-01-01

    The following topics were discussed: Definition of stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT); Stereo market; Indications for SRS/SRT; History of linac-based SRS/SRT; Variety of systems; QA for SRS; Localization; and Imaging. (P.A.)

  16. A new treatment method for brain diseases. Stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Shirato, Hiroki

    1994-01-01

    This paper deals with stereotactic radiosurgery, a novel medical treatment technique for brain diseases. It is the most sophisticated modality that allows the functional preservation. Recently, CT scan and MRI scan have dramatically changed the diagnostic accuracy of tumor localization in the brain. A device named stereotactic head fixation system makes it possible to localize deep-seated brain diseases with an accuracy of 1-1.5 mm. Using multiple convergent narrow beams of high-energy X-ray, a stereotactic head frame, and a three dimensional computer graphics of CT images, patients with deep-seated nidus can be treated without any complications. Normal tissues would not receive large doses but the center of the nidus is irradiated heavily because of the convergence of X-ray beams. Thus stereotactic radiosurgery is more accurate, effective, and less toxic than conventional radiotherapy and is safer and more effective than surgery for many brain diseases. Small arteriovenous malformation in the brain, which is a fetal disease, and small acoustic neurinomas, in which surgery often causes facial nerve palsy and hearing loss, are presented as good candidates for radiosurgery. For metastatic brain tumors, stereotactic radiosurgery makes such patients free from neurological symptoms, such as difficulty in walking and speaking, in a few days. (N.K.)

  17. Trilogy Image-Guided Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Huntzinger, Calvin; Friedman, William; Bova, Frank; Fox, Timothy; Bouchet, Lionel; Boeh, Lester M.B.A.

    2007-01-01

    Full integration of advanced imaging, noninvasive immobilization, positioning, and motion-management methods into radiosurgery have resulted in fundamental changes in therapeutic strategies and approaches that are leading us to the treatment room of the future. With the introduction of image-guided radiosurgery (IGRS) systems, such as Trilogy TM , physicians have for the first time a practical means of routinely identifying and treating very small lesions throughout the body. Using new imaging processes such as positron emission tomography/computed tomography (PET/CT) scans, clinics may be able to detect these lesions and then eradicate them with image-guided stereotactic radiosurgery treatments. Thus, there is promise that cancer could be turned into a chronic disease, managed through a series of checkups, and Trilogy treatments when metastatic lesions reappear

  18. Stereotactic Radiosurgery (SRS) / Stereotactic body radiotherapy (SBRT): Benefit to Irish patients and Irish Healthcare Economy

    LENUS (Irish Health Repository)

    Cagney, DN

    2017-01-01

    Cancer incidence across Europe is projected to rise rapidly over the next decade. This rising cancer incidence is mirrored by increasing use of and indications for stereotactic radiation. This paper seeks to summarize the exponential increase in indications for stereotactic radiotherapy as well as the evolving economic advantages of stereotactic radiosurgery and stereotactic body radiotherapy

  19. Stereotactic Radiosurgery and Hypofractionated Radiotherapy for Glioblastoma.

    Science.gov (United States)

    Shah, Jennifer L; Li, Gordon; Shaffer, Jenny L; Azoulay, Melissa I; Gibbs, Iris C; Nagpal, Seema; Soltys, Scott G

    2018-01-01

    Glioblastoma is the most common primary brain tumor in adults. Standard therapy depends on patient age and performance status but principally involves surgical resection followed by a 6-wk course of radiation therapy given concurrently with temozolomide chemotherapy. Despite such treatment, prognosis remains poor, with a median survival of 16 mo. Challenges in achieving local control, maintaining quality of life, and limiting toxicity plague treatment strategies for this disease. Radiotherapy dose intensification through hypofractionation and stereotactic radiosurgery is a promising strategy that has been explored to meet these challenges. We review the use of hypofractionated radiotherapy and stereotactic radiosurgery for patients with newly diagnosed and recurrent glioblastoma. Copyright © 2017 by the Congress of Neurological Surgeons.

  20. Stereotactic radiosurgery: basic concepts and current status

    International Nuclear Information System (INIS)

    Gaur, Maheep Singh

    2016-01-01

    Term Stereotactic Radiosurgery was coined by Prof Lars Leksell in 1951 as concept. Leksell's experimented together with the radiobiologist Borje Larsson in Uppsala, on trying to develop 'stereotactic radiosurgery', aimed at lesioning in the central brain in functional operations such as thalamotomy and capsulotomy. Clinical experiments using a proton beam were initiated at the Gustav Werner Institute in Uppsala, and a few patients had been treated. Experiences from these led Leksell to design a multi-source 'beam knife', which became ready for use in 1967 as the first 'Gamma Knife' and installed at the private hospital Sophiahammet in Stockholm as a clinical research unit. Moving from functional neurosurgery today Gamma knife is used for a wide range on brain tumors, vascular malformations and functional disorders. Introduction of newer technology in navigation and radiation delivery has made it possible to do whole body Radiosurgery. Various technologies, basic principles, radiobiological aspects and applications will be discussed. (author)

  1. Stereotactic radiosurgery for hemangioblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Yoshimasa; Kobayashi, Tatsuya; Yamada, Yasushi; Kida, Yoshihisa; Iwakoshi, Takayasu; Yoshimoto, Masayuki [Komaki City Hospital, Aichi (Japan). Gamma Knife Center

    2001-12-01

    We evaluated the treatment results of Gamma Knife radiosurgery for intracranial hemanigioblastoma of von Hippel-Lindau syndrome or sporadic disease. Stereotactic radiosurgery was performed in 20 patients with 35 hemangioblastomas over a 9-year interval. The mean age of the patients was 48.5 years (range, 18-79 years). The volume of the tumors varied from 0.03 to 19 ml (mean, 3.0 ml), and the mean tumor margin dose was 17.8 Gy (range, 14-24 Gy). Clinical and neuroimaging follow-up was obtained 6 to 58 months (mean 26.2 months) after radiosurgery. Thirty-one (89%) of 35 tumors were controlled locally. Two tumors (6%) disappeared and 11 (31%) decreased in size during follow-up period. Eighteen (52%) remained unchanged in size. Three out of four enlarged tumors were resected surgically after radiosurgery. Another tumor was resected surgically to improve the patient's symptoms of nausea and vomiting caused by persistent perifocal edema in spite of reduced tumor volume. Only one patient, who had a tumor in the 4th ventricle arising from the brainstem, died 12 months after radiosurgery. Although the treated tumor remained stable in size, he developed aspiration pneumonia due to brainstem dysfunction caused by perifocal edema. All tumors less than 1 cm in diameter did not progress during follow-up period. For small hemangioblastomas, radiosurgery is a safe and effective option to control disease. If a large tumor is treated by radiosurgery, careful observation of the patient's neurological condition is necessary. (author)

  2. Stereotactic radiosurgery for the treatment of brain metastases; results from a single institution experience.

    LENUS (Irish Health Repository)

    Burke, D

    2013-09-01

    Stereotactic radiosurgery is frequently used for the treatment of brain metastases. This study provides a retrospective evaluation of patients with secondary lesions of the brain treated with stereotactic radiosurgery (SRS) at our institution.

  3. Management of vestibular schwannomas with linear accelerator-based stereotactic radiosurgery: a single center experience.

    Science.gov (United States)

    Sager, Omer; Beyzadeoglu, Murat; Dincoglan, Ferrat; Demiral, Selcuk; Uysal, Bora; Gamsiz, Hakan; Oysul, Kaan; Dirican, Bahar; Sirin, Sait

    2013-01-01

    The primary goal of treatment for vestibular schwannoma is to achieve local control without comprimising regional cranial nerve function. Stereotactic radiosurgery has emerged as a viable therapeutic option for vestibular schwannoma. The aim of the study is to report our 15-year single center experience using linear accelerator-based stereotactic radiosurgery in the management of patients with vestibular schwannoma. Between July 1998 and January 2013, 68 patients with unilateral vestibular schwannoma were treated using stereotactic radiosurgery at the Department of Radiation Oncology, Gulhane Military Medical Academy. All patients underwent high-precision stereotactic radiosurgery using a linear accelerator with 6-MV photons. Median follow-up time was 51 months (range, 9-107). Median age was 45 years (range, 20-77). Median dose was 12 Gy (range, 10-13) prescribed to the 85%-95% isodose line encompassing the target volume. Local tumor control in patients with periodic follow-up imaging was 96.1%. Overall hearing preservation rate was 76.5%. Linear accelerator-based stereotactic radiosurgery offers a safe and effective treatment for patients with vestibular schwannoma by providing high local control rates along with improved quality of life through well-preserved hearing function.

  4. Measurement of relative dose distributions in stereotactic radiosurgery by the polymer-gel dosimeter

    Czech Academy of Sciences Publication Activity Database

    Novotný ml., J.; Spěváček, V.; Hrbáček, J.; Judas, L.; Novotný, J.; Dvořák, P.; Tlacháčová, D.; Schmitt, M.; Tintěra, J.; Vymazal, J.; Čechák, T.; Michálek, Jiří; Přádný, Martin; Liščák, R.

    2004-01-01

    Roč. 5, - (2004), s. 225-235 ISSN 1024-2651. [International Stereotactic Radiosurgery Society Meeting /6./. Kyoto, 22.06.2003-26.06.2003] R&D Projects: GA MZd NC7460 Institutional research plan: CEZ:AV0Z4050913 Keywords : stereotactic radiosurgery * polymer-gel dosimeter Subject RIV: FD - Oncology ; Hematology

  5. Stereotactic radiosurgery planning with ictal SPECT images

    International Nuclear Information System (INIS)

    Ackerly, T.; RMIT University, Bundoora, VIC; Geso, M.; O'Keefe, G.; Smith, R.

    2004-01-01

    This paper is motivated by a clinical requirement to utilise ictal SPECT images for target localisation in stereotactic radiosurgery treatment planning using the xknife system which only supports CT and MRI images. To achieve this, the SPECT images were converted from raw (pixel data only) format into a part 10 compliant DICOM CT fileset. The minimum requirements for the recasting of a raw format image as DICOM CT or MRI data set are described in detail. The method can be applied to the importation of raw format images into any radiotherapy treatment planning system that supports CT or MRI import. It is demonstrated that the combination of the low spatial resolution SPECT images, depicting functional information, with high spatial resolution MRI images, which show the structural information, is suitable for stereotactic radiosurgery treatment planning. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  6. Stereotactic radiosurgery with an upper partial denture

    International Nuclear Information System (INIS)

    Tayama, Shusaku; Kunieda, Etsuo; Takeda, Atsushi; Takeda, Toshiaki; Oku, Yohei

    2009-01-01

    A 54-year-old male with partial denture underwent stereotactic radiosurgery with an infrared camera-guided system for a metastatic brain tumor arising from lung cancer. Although this method utilizes a biteplate mounted on the upper jaw to detect head movement, the patient only had four teeth in his upper jaw. In order to stabilize the biteplate, the maxillary denture was fixed to the biteplate with an autopolymerizing resin. In addition, the rest-occlusal position of the lower jaw was impressed on the inferior surface of the biteplate with an autopolymerizing resin. To assess reproducibility and stability, the distance between the left and right incus and left and right markers was measured during pre-planning, as well as before and after stereotactic irradiation. Wearing the biteplate ensures the accuracy of radiotherapy planning for the implementation of radiosurgery in patients who have many maxillary teeth missing. However, a large degree of error was observed when the biteplate was removed. (author)

  7. Heavy-ion radiography applied to charged particle radiotherapy

    International Nuclear Information System (INIS)

    Chen, G.T.Y.; Fabrikant, J.I.; Holley, W.R.; Tobias, C.A.; Castro, J.R.

    1980-01-01

    The objectives of the heavy-ion radiography research program applied to the clinical cancer research program of charged particle radiotherapy have a twofold purpose: (1) to explore the manner in which heavy-ion radiography and CT reconstruction can provide improved tumor localization, treatment planning, and beam delivery for radiotherapy with accelerated heavy charged particles; and (2) to explore the usefulness of heavy-ion radiography in detecting, localizing, and sizing soft tissue cancers in the human body. The techniques and procedures developed for heavy-ion radiography should prove successful in support of charged particle radiotherapy

  8. Clinical results of stereotactic helium-ion radiosurgery of the pituitary gland at Lawrence Berkeley Laboratory

    International Nuclear Information System (INIS)

    Levy, R.P.; Fabrikant, J.I.; Lyman, J.T.; Frankel, K.A.; Phillips, M.H.; Lawrence, J.H.; Tobias, C.A.

    1989-12-01

    The first therapeutic clinical trial using accelerated heavy-charged particles in humans was performed for the treatment of various endocrine and metabolic disorders of the pituitary gland, and as suppressive therapy for adenohypophyseal hormone-responsive carcinomas and diabetic retinopathy. Since then, over 800 patients have received stereotactically-directed plateau-beam heavy-charged particle pituitary irradiation at this institution. In acromegaly, Cushing's disease, Nelson's syndrome and prolactin-secreting tumors, the therapeutic goal in the 433 patients treated has been to destroy or inhibit the growth of the pituitary tumor and control hormonal hypersecretion, while preserving a functional rim of tissue with normal hormone-secreting capacity, and minimizing neurologic injury. An additional group of 34 patients was treated for nonsecreting chromophobe adenomas. This paper discusses the methods and results of these treatments. 11 refs

  9. The study on linac stereotactic radiosurgery for acoustic tumors

    International Nuclear Information System (INIS)

    Ohishi, Hitoshi

    1995-01-01

    We have designed and manufactured a new type of device for stereotactic radiosurgery characterized by the combined use of a rotatory chair and a linear accelerator. In this study, 20 acoustic tumors treated by our modality were evaluated by serial neuroimaging, neurofunctional outcome and, in a few cases, pathological findings of surgical specimens. Because tumor size usually changed very slowly after radiosurgery, 12 cases that had a minimum of 12 months of follow-up were employed in the analysis of tumor size. Serial neuroimaging studies revealed the reduction of tumor size in 3 cases and prevention of tumor growth in 7 cases, therefore, the rate of tumor control was evaluated as 83%. Growth of tumor size occurred in 3 cases, two were cases harbouring a large cyst in the tumor and another was a case of neurofibromatosis type 2. In 13 cases (68%), loss of the gadolinium enhancement effect inside the tumor was observed. This is a characteristic change after radiosurgery for acoustic tumors, and attributable to a necrotic change. Cranial nerve neuropathies as a complication also occurred (facial nerve palsy in 2 and trigeminal nerve dysfunction in 1). Adjacent parenchymal change appeared in 1 case. This patient had two prior operations and the tumor had an irregular shape, therefore, planning for radiosurgery encountered some difficulty. Hydrocephalus occurred in 1 case. Surgical specimens in 2 cases in which microsurgery was undertaken for growing tumors, revealed a necrotic tumor tissue and proliferation of fibrous tissue. In conclusion, our new device for stereotactic radiosurgery is particularly useful for the treatment of acoustic tumors. Similar therapeutic results of the gamma knife have been achieved. Radiosurgery is a recommendable treatment for acoustic tumors. However, the superiority of radiosurgery over microsurgery is still controversial and needs a longer term follow-up and multivariate analysis for a final conclusion. (author)

  10. Clinical results of stereotactic helium-ion radiosurgery of the pituitary gland at Lawrence Berkeley Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R.P.; Fabrikant, J.I.; Lyman, J.T.; Frankel, K.A.; Phillips, M.H.; Lawrence, J.H.; Tobias, C.A.

    1989-12-01

    The first therapeutic clinical trial using accelerated heavy-charged particles in humans was performed for the treatment of various endocrine and metabolic disorders of the pituitary gland, and as suppressive therapy for adenohypophyseal hormone-responsive carcinomas and diabetic retinopathy. Since then, over 800 patients have received stereotactically-directed plateau-beam heavy-charged particle pituitary irradiation at this institution. In acromegaly, Cushing's disease, Nelson's syndrome and prolactin-secreting tumors, the therapeutic goal in the 433 patients treated has been to destroy or inhibit the growth of the pituitary tumor and control hormonal hypersecretion, while preserving a functional rim of tissue with normal hormone-secreting capacity, and minimizing neurologic injury. An additional group of 34 patients was treated for nonsecreting chromophobe adenomas. This paper discusses the methods and results of these treatments. 11 refs.

  11. [Possibility of 3D Printing in Ophthalmology - First Experiences by Stereotactic Radiosurgery Planning Scheme of Intraocular Tumor].

    Science.gov (United States)

    Furdová, A; Furdová, Ad; Thurzo, A; Šramka, M; Chorvát, M; Králik, G

    Nowadays 3D printing allows us to create physical objects on the basis of digital data. Thanks to its rapid development the use enormously increased in medicine too. Its creations facilitate surgical planning processes, education and research in context of organ transplantation, individualization prostheses, breast forms, and others.Our article describes the wide range of applied 3D printing technology possibilities in ophthalmology. It is focusing on innovative implementation of eye tumors treatment planning in stereotactic radiosurgery irradiation.We analyze our first experience with 3D printing model of the eye in intraocular tumor planning stereotactic radiosurgery. 3D printing, model, Fused Deposition Modelling, stereotactic radiosurgery, prostheses, intraocular tumor.

  12. Linear accelerator stereotactic radiosurgery for trigeminal neuralgia.

    Science.gov (United States)

    Varela-Lema, Leonor; Lopez-Garcia, Marisa; Maceira-Rozas, Maria; Munoz-Garzon, Victor

    2015-01-01

    Stereotactic radiosurgery is accepted as an alternative for patients with refractory trigeminal neuralgia, but existing evidence is fundamentally based on the Gamma Knife, which is a specific device for intracranial neurosurgery, available in few facilities. Over the last decade it has been shown that the use of linear accelerators can achieve similar diagnostic accuracy and equivalent dose distribution. To assess the effectiveness and safety of linear-accelerator stereotactic radiosurgery for the treatment of patients with refractory trigeminal neuralgia. We carried out a systematic search of the literature in the main electronic databases (PubMed, Embase, ISI Web of Knowledge, Cochrane, Biomed Central, IBECS, IME, CRD) and reviewed grey literature. All original studies on the subject published in Spanish, French, English, and Portuguese were eligible for inclusion. The selection and critical assessment was carried out by 2 independent reviewers based on pre-defined criteria. In view of the impossibility of carrying out a pooled analysis, data were analyzed in a qualitative way. Eleven case series were included. In these, satisfactory pain relief (BIN I-IIIb or reduction in pain = 50) was achieved in 75% to 95.7% of the patients treated. The mean time to relief from pain ranged from 8.5 days to 3.8 months. The percentage of patients who presented with recurrences after one year of follow-up ranged from 5% to 28.8%. Facial swelling or hypoesthesia, mostly of a mild-moderate grade appeared in 7.5% - 51.9% of the patients. Complete anaesthesia dolorosa was registered in only study (5.3%). Cases of hearing loss (2.5%), brainstem edema (5.8%), and neurotrophic keratoplasty (3.5%) were also isolated. The results suggest that stereotactic radiosurgery with linear accelerators could constitute an effective and safe therapeutic alternative for drug-resistant trigeminal neuralgia. However, existing studies leave important doubts as to optimal treatment doses or the

  13. Stereotactic radiosurgery using a linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Kyuma, Yoshikazu; Hayashi, Akimune; Kitamura, Tatsuo; Yamashita, Koosuke; Muranishi, Hisayuki; Hioki, Minoru [Kanagawa Cancer Center, Yokohama (Japan)

    1992-07-01

    A basic and clinical study of radiosurgery using the linear accelerator (Linac) system for unremovable deep-seated brain tumors is reported. A Komai stereotactic ring was used to locate the target coordinates. The patient was laid on the Linac treatment table and held in the head fixation system. Irradiation was given in five positions. The dose profile by film dosimetry and Rando phantom was satisfactory. Seventeen tumors in 14 patients were treated. Clinical or histological diagnoses were nine metastases, one benign and two malignant gliomas, one meningioma, and one carcinopharyngioma. Tumor sizes were between 8 and 30 mm. Doses were between 12 and 30 Gy. Computed tomographic evaluation after 3 months of 12 tumors in 11 survivors showed one complete remission, three partial remission, six no change, and two partial deterioration. For progressive tumors, Linac radiosurgery results are excellent. (author).

  14. Neurosurgical applications of ion beams

    Science.gov (United States)

    Fabrikant, Jacob I.; Levy, Richard P.; Phillips, Mark H.; Frankel, Kenneth A.; Lyman, John T.

    1989-04-01

    The program at Donner Pavilion has applied nuclear medicine research to the diagnosis and radiosurgical treatment of life-threatening intracranial vascular disorders that affect more than half a million Americans. Stereotactic heavy-charged-particle Bragg peak radiosurgery, using narrow beams of heavy ions, demonstrates superior biological and physical characteristics in brain over X-and γ-rays, viz., improved dose distribution in the Bragg peak and sharp lateral and distal borders and less scattering of the beam. Examination of CNS tissue response and alteration of cerebral blood-flow dynamics related to heavy-ion Bragg peak radiosurgery is carried out using three-dimensional treatment planning and quantitative imaging utilizing cerebral angiography, computerized tomography (CT), magnetic resonance imaging (MRI), cine-CT, xenon X-ray CT and positron emission tomography (PET). Also under examination are the physical properties of narrow heavy-ion beams for improving methods of dose delivery and dose distribution and for establishing clinical RBE/LET and dose-response relationships for human CNS tissues. Based on the evaluation and treatment with stereotactically directed narrow beams of heavy charged particles of over 300 patients, with cerebral angiography, CT scanning and MRI and PET scanning of selected patients, plus extensive clinical and neuroradiological followup, it appears that Stereotactic charged-particle Bragg peak radiosurgery obliterates intracranial arteriovenous malformations or protects against rebleeding with reduced morbidity and no mortality. Discussion will include the method of evaluation, the clinical research protocol, the Stereotactic neuroradiological preparation, treatment planning, the radiosurgery procedure and the protocol for followup. Emphasis will be placed on the neurological results, including the neuroradiological and clinical response and early and late delayed injury in brain leading to complications (including vasogenic edema

  15. Proton beam stereotactic radiosurgery of vestibular schwannomas

    International Nuclear Information System (INIS)

    Harsh, Griffith R.; Thornton, Allan F.; Chapman, Paul H.; Bussiere, Marc R.; Rabinov, James D.; Loeffler, Jay S.

    2002-01-01

    Purpose: The proton beam's Bragg peak permits highly conformal radiation of skull base tumors. This study, prompted by reports of transient (30% each) and permanent (10% each) facial and trigeminal neuropathy after stereotactic radiosurgery of vestibular schwannomas with marginal doses of 16-20 Gy, assessed whether proton beam radiosurgery using a marginal dose of only 12 Gy could control vestibular schwannomas while causing less neuropathy. Methods and Materials: Sixty-eight patients (mean age 67 years) were treated between 1992 and 1998. The mean tumor volume was 2.49 cm 3 . The dose to the tumor margin (70% isodose line) was 12 Gy. The prospectively specified follow-up consisted of neurologic evaluation and MRI at 6, 12, 24, and 36 months. Results: After a mean clinical follow-up of 44 months and imaging follow-up of 34 months in 64 patients, 35 tumors (54.7%) were smaller and 25 (39.1%) were unchanged (tumor control rate 94%; actuarial control rate 94% at 2 years and 84% at 5 years). Three tumors enlarged: one shrank after repeated radiosurgery, one remained enlarged at the time of unrelated death, and one had not been imaged for 4 years in a patient who remained asymptomatic at last follow-up. Intratumoral hemorrhage into one stable tumor required craniotomy that proved successful. Thus, 97% of tumors required no additional treatment. Three patients (4.7%) underwent shunting for hydrocephalus evident as increased ataxia. Of 6 patients with functional hearing ipsilaterally, 1 improved, 1 was unchanged, and 4 progressively lost hearing. Cranial neuropathies were infrequent: persistent facial hypesthesia (2 new, 1 exacerbated; 4.7%); intermittent facial paresthesias (5 new, 1 exacerbated; 9.4%); persistent facial weakness (2 new, 1 exacerbated; 4.7%) requiring oculoplasty; transient partial facial weakness (5 new, 1 exacerbated; 9.4%), and synkinesis (5 new, 1 exacerbated; 9.4%). Conclusion: Proton beam stereotactic radiosurgery of vestibular schwannomas at the

  16. Stereotactic Target point Verification in Actual Treatment Position of Radiosurgery

    International Nuclear Information System (INIS)

    Yun, Hyong Geun; Lee, Hyun Koo

    1995-01-01

    Purpose : Authors tried to enhance the safety and accuracy of radiosurgery by verifying stereotactic target point in actual treatment position prior to irradiation. Materials and Methods : Before the actual treatment, several sections of anthropomorphic head phantom were used to create a condition of unknown coordinated of the target point. A film was sand witched between the phantom sections and punctured by sharp needle tip. The tip of the needle represented the target point. The head phantom was fixed to the stereotactic ring and CT scan was done with CT localizer attached to the ring. After the CT scanning, the stereotactic coordinates of the target point were determined. The head phantom was secured to accelerator's treatment couch and the movement of laser isocenter to the stereotactic coordinates determined by CT scanning was performed using target positioner. Accelerator's anteroposterior and lateral portal films were taken using angiographic localizers. The stereotactic coordinates determined by analysis of portal films were compared with the stereotactic coordinates previously determined by CT scanning. Following the correction of discrepancy, the head phantom was irradiated using a stereotactic technique of several arcs. After the irradiation, the film which was sand witched between the phantom sections was developed and the degree of coincidence between the center of the radiation distribution with the target point represented by the hole in the film was measured. In the treatment of actual patients, the way of determining the stereotactic coordinates with CT localizers and angiographic localizers between two sets of coordinates, we proceeded to the irradiation of the actual patient. Results : In the phantom study, the agreement between the center of the radiation distribution and the localized target point was very good. By measuring optical density profiles of the sand witched film along axes that intersected the target point, authors could confirm

  17. Vagus nerve stimulation and stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Kawai, Kensuke

    2005-01-01

    Vagus nerve stimulation and stereotactic radiosurgery represent novel and less invasive therapeutics for medically intractable epilepsy. Chronic stimulation of the left vagus nerve with implanted generator and electrodes inhibits seizure susceptibility of the cerebral cortices. While the underlying mechanisms of the effect remains to be further elucidated, the efficacy and safety of vagus nerve stimulation have been established by randomized clinical trials in the United States and European countries. It has been widely accepted as a treatment option for patients with medically intractable epilepsy and for whom brain surgery is not indicated. The primary indication of vagus nerve stimulation in the clinical trials was localization-related epilepsy in adult patients but efficacy in a wide range of patient groups such as generalized epilepsy and children has been reported. Improvements in daytime alertness, mood, higher cognitive functions and overall quality of life have been reported other than the effect on epileptic seizures. Since the devices are not approved for clinical use in Japan by the Health, Labor and Welfare Ministry, there exist barriers to provide this treatment to patients at present. Stereotactic radiosurgery has been used for temporal lobe epilepsy and hypothalamic hamartoma, but it is still controversial whether the therapy is more effective and less invasive than brain surgery. Promising results of gamma knife radiosurgery for medically intractable temporal lobe epilepsy with unilateral hippocampal sclerosis have been reported essentially from one French center. Results from others were not as favorable. There seems to be an unignorable risk of brain edema and radiation necrosis when the delivered dose over the medial temporal structures is high enough to abolish epileptic seizures. A randomized clinical trial comparing different marginal doses is ongoing in the United States. Clinical trials like this, technical advancement and standardization

  18. Anniversary Paper: The role of medical physicists in developing stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Benedict, Stanley H.; Bova, Frank J.; Clark, Brenda; Goetsch, Steven J.; Hinson, William H.; Leavitt, Dennis D.; Schlesinger, David J.; Yenice, Kamil M.

    2008-01-01

    This article is a tribute to the pioneering medical physicists over the last 50 years who have participated in the research, development, and commercialization of stereotactic radiosurgery (SRS) and stereotactic radiotherapy utilizing a wide range of technology. The authors have described the evolution of SRS through the eyes of physicists from its beginnings with the Gamma Knife in 1951 to proton and charged particle therapy; modification of commercial linacs to accommodate high precision SRS setups; the multitude of accessories that have enabled fine tuning patients for relocalization, immobilization, and repositioning with submillimeter accuracy; and finally the emerging technology of SBRT. A major theme of the article is the expanding role of the medical physicist from that of advisor to the neurosurgeon to the current role as a primary driver of new technology that has already led to an adaptation of cranial SRS to other sites in the body, including, spine, liver, and lung. SRS continues to be at the forefront of the impetus to provide technological precision for radiation therapy and has demonstrated a host of downstream benefits in improving delivery strategies for conventional therapy as well. While this is not intended to be a comprehensive history, and the authors could not delineate every contribution by all of those working in the pursuit of SRS development, including physicians, engineers, radiobiologists, and the rest of the therapy and dosimetry staff in this important and dynamic radiation therapy modality, it is clear that physicists have had a substantial role in the development of SRS and theyincreasingly play a leading role in furthering SRS technology

  19. Stereotactic radiosurgery in the palliative treatment of brain metastases

    International Nuclear Information System (INIS)

    Faria, Sergio L.; Souhami, Luis; Bahary, Jean-Paul; Clark, Brenda; Adamson, Nelson; Podgorsak, Ervin B.; Caron, Jean-Louis; Villemure, Jean-Guy; Olivier, Andre

    1995-01-01

    Between October, 1988 and November, 1993, 57 patients with metastatic brain disease underwent stereotactic radiosurgery at McGill University, canada. Four patients were excluded from this analysis leaving a total of 53 evaluable patients (with 57 lesions). Radiosurgery was performed with the dynamic rotation technique which uses an isocentric, 10 MV, linear accelerator. A median dose of 1,800 c Gy was given in a single session. In 89% of the cases radiosurgery was used after failure to conventional brain radiotherapy. With a median follow-up of 6 months, the response rate was 65% . Treatments were well tolerated and only 4 patients (7%) developed late complications related to the therapy, with one patient requiring a surgical resection of an area of radionecrose. Radiosurgery appears to be and effective and safe treatment for selected patients with metastatic brain disease, recurrent post-conventional radiotherapy. Its value as a single treatment modality for patients with isolated brain metastasis is now being studied in prospective trials. (author). 29 refs., 4 figs., 4 tabs

  20. Radiocromic film, TLD, OSL and 'Paracas Phantom' by dosimetric intercomparation in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Paucar Jauregui, R.; Condori Marcos, P.; Vidarte Garcia, F.

    2008-01-01

    Full text: In Peru, one deals to patients with arteriovenous malformations or cerebral tumors by means of stereotactic radiosurgery, using fine photon beams of high energy of 6 MeV, generated by a linear accelerator Varian 2100 Clinac CD of the Complejo Hospitalario San Pablo in Lima, Peru. In this work we describes the 'Dosimetric Intercomparation System of the Quality Assurance Program in Stereotactic Radiosurgery of the Complejo Hospitalario San Pablo (DIS)'. The DIS allows to guarantee application of the doses with high accuracy. It shows the good performance of the Local DIS's components: dosimetry of radiocromics films, dosimetry termoluminiscent (TLD), dosimetry of optically stimulated luminescence (OSL) and an anthropomorphic phantom of head constructed locally, denominated 'Paracas Phantom'. Also, in the International DIS practiced with The University of Texas Md Anderson Cancer Center, stands out results within the ranges: a) Dose to the center of the target (RDS/Institution): 0,95-1,05; b) Treated volumen (Measured/Institution): 0,75 - 1,05; c) Ratio of measure treated volume to target volume: 1,00 - 2,00; and d) Minimum dose to target (Minimum dose/Prescription dose): >0,90. It concludes that the DIS is important for the good decision making on the radiological safety of the patients dealt with stereotactic radiosurgery. (author)

  1. Frameless stereotactic radiosurgery of a solitary liver metastasis using active breathing control and stereotactic ultrasound

    International Nuclear Information System (INIS)

    Boda-Heggemann, J.; Walter, C.; Mai, S.; Dobler, B.; Wenz, F.; Lohr, F.; Dinter, D.

    2006-01-01

    Background and purpose: radiosurgery of liver metastases is effective but a technical challenge due to respiration-induced movement. The authors report on the initial experience of the combination of active breathing control (ABC registered ) with stereotactic ultrasound (B-mode acquisition and targeting [BAT registered ]) for frameless radiosurgery. Patient and methods: a patient with a solitary, inoperable liver metastasis from cholangiocellular carcinoma is presented. ABC registered was used for tumor/liver immobilization. Tumor/liver position was controlled and corrected using ultrasound (BAT registered ). The tumor was irradiated with a single dose of 24 Gy. Results: using ABC registered , the motion of the tumor was significantly reduced and the overall positioning error was registered allowed a rapid localization of the lesion during breath hold which could be performed without difficulties for 20 s. Overall treatment time was acceptable (30 min). Conclusion: frameless stereotactic radiotherapy with the combination of ABC registered and BAT registered allows the delivery of high single doses to targets accessible to ultrasound with high precision comparable to a frame-based approach. (orig.)

  2. Stereotactic radiosurgery versus stereotactic radiotherapy for patients with vestibular schwannoma: a Leksell Gamma Knife Society 2000 debate.

    Science.gov (United States)

    Linskey, Mark E

    2013-12-01

    By definition, the term "radiosurgery" refers to the delivery of a therapeutic radiation dose in a single fraction, not simply the use of stereotaxy. Multiple-fraction delivery is better termed "stereotactic radiotherapy." There are compelling radiobiological principles supporting the biological superiority of single-fraction radiation for achieving an optimal therapeutic response for the slowly proliferating, late-responding, tissue of a schwannoma. It is axiomatic that complication avoidance requires precise three-dimensional conformality between treatment and tumor volumes. This degree of conformality can only be achieved through complex multiisocenter planning. Alternative radiosurgery devices are generally limited to delivering one to four isocenters in a single treatment session. Although they can reproduce dose plans similar in conformality to early gamma knife dose plans by using a similar number of isocenters, they cannot reproduce the conformality of modern gamma knife plans based on magnetic resonance image--targeted localization and five to 30 isocenters. A disturbing trend is developing in which institutions without nongamma knife radiosurgery (GKS) centers are championing and/or shifting to hypofractionated stereotactic radiotherapy for vestibular schwannomas. This trend appears to be driven by a desire to reduce complication rates to compete with modern GKS results by using complex multiisocenter planning. Aggressive advertising and marketing from some of these centers even paradoxically suggests biological superiority of hypofractionation approaches over single-dose radiosurgery for vestibular schwannomas. At the same time these centers continue to use the term radiosurgery to describe their hypofractionated radiotherapy approach in an apparent effort to benefit from a GKS "halo effect." It must be reemphasized that as neurosurgeons our primary duty is to achieve permanent tumor control for our patients and not to eliminate complications at the

  3. The value of image coregistration during stereotactic radiosurgery.

    Science.gov (United States)

    Koga, T; Maruyama, K; Igaki, H; Tago, M; Saito, N

    2009-05-01

    Coregistration of any neuroimaging studies into treatment planning for stereotactic radiosurgery became easily applicable using the Leksell Gamma Knife 4C, a new model of gamma knife. The authors investigated the advantage of this image processing. Since installation of the Leksell Gamma Knife 4C at the authors' institute, 180 sessions of radiosurgery were performed. Before completion of planning, coregistration of frameless images of other modalities or previous images was considered to refine planning. Treatment parameters were compared for planning before and after refinement by use of coregistered images. Coregistered computed tomography clarified the anatomical structures indistinct on magnetic resonance imaging. Positron emission tomography visualized lesions disclosing metabolically high activity. Coregistration of prior imaging distinguished progressing lesions from stable ones. Diffusion-tensor tractography was integrated for lesions adjacent to the corticospinal tract or the optic radiation. After refinement of planning in 36 sessions, excess treated volume decreased (p = 0.0062) and Paddick conformity index improved (p < 0.001). Maximal dose to the white matter tracts was decreased (p < 0.001). Image coregistration provided direct information on anatomy, metabolic activity, chronological changes, and adjacent critical structures. This gathered information was sufficiently informative during treatment planning to supplement ambiguous information on stereotactic images, and was useful especially in reducing irradiation to surrounding normal structures.

  4. Stereotactic radiosurgery may contribute to overall survival for patients with recurrent head and neck carcinoma

    International Nuclear Information System (INIS)

    Kawaguchi, Koji; Sato, Kengo; Horie, Akihisa; Iketani, Susumu; Yamada, Hiroyuki; Nakatani, Yasunori; Sato, Junichi; Hamada, Yoshiki

    2010-01-01

    The aim of this study is to examine the effect of stereotactic radiosurgery (SRS) in the treatment of advanced, recurrent lesions for head and neck carcinoma both with and without lymph node involvement. Between April 2006 and July 2007, 22 patients (mean age 67 years) with advanced, recurrent head and neck carcinoma were treated with stereotactic radiosurgery. All of the patients except one had biopsy confirmed disease prior to stereotactic radiosurgery. Patients included 3 rT2, 8 rT3, and 9 rT4; 8 of the patients had lymph node metastases. Marginal SRS doses were 20-42 Gy delivered in two to five fractions. Starting one month after SRS, all patients received S-1 oral chemotherapy for one year. At an overall median follow-up of 24 months (range, 4-39 months), for the 14 locally recurrent patients without lymph node metastases, 9 patients (64.3%) had a complete response (CR), 1 patient (7.1%) had a partial response (PR), 1 patient (7.1%) had stable disease (SD), and 3 patients (21.4%) had progressive disease (PD). For the 8 patients with lymph node metastases, 1 patient with a single retropharyngeal (12.5%) had CR; the remaining 7 patients (87.5%) all progressed. Nine patients have died from their cancer. The overall actuarial 2-year survival for the patients with and without lymph node metastases is 12.5% and 78.6%, respectively. These results show the benefit of stereotactic radiosurgery salvage treatment for advanced, recurrent lesions, without lymph node metastases in previously irradiated head and neck cancer

  5. Dosimetric evaluation of proton stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Min, Byung Jun; Shin, Dong Ho; Yoo, Seung Hoon; Jeong, Hojin; Lee, Se Byeong

    2011-01-01

    Surgical excision, conventional external radiotherapy, and chemotherapy could prolong survival in patients with small intracranial tumors. However, surgical excision for meningiomas located in the region of the base of skull or re-resection is often difficult. Moreover, treatment is needed for patients with recurrent tumors or postoperative residual tumors. Conventional external radiotherapy is popular and has significantly increased for treating brain tumors. Stereotactic radiosurgery is an effective alternative treatment technique to microsurgical resection such as benign brain tumor or vestibular Schwannomas. In general, the dose to OAR of 3D conformal plan is lower than that of conformal arc and dynamic conformal arc plans. However, any of OARs was not reached to tolerance dose. Although mean dose of the healthy brain tissue for 3D conformal plan was slightly higher than that of arc plans, the doses of the healthy brain tissue at V10 and V20 were significantly low for dynamic conformal arc plan. The dosimetric differences were the greatest at lower doses. In contrast, 3D conformal plan was better spare at higher doses. In this study, a dosimetric evaluation of proton stereotactic radiosurgery for brain lesion tumors was using fixed and arc beams. A brass block fitted to the PTV structure was modeled for dynamic conformal collimator. Although all treatment plans offer a very good coverage of the PTV, we found that proton arc plans had significantly better conformity to the PTV than static 3D conformal plan. The V20 dose of normal brain for dynamic conformal arc therapy is dramatically reduced compare to those for other therapy techniques.

  6. Stereotactic Radiosurgery for Intracranial Tumors : Early Experience with Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Chang Ok; Chung, Sang Sup; Chu, Sung Sil; Kim, Young Soo; Yoon, Do Heum; Kim, Sun Ho; Loh, John Juhn; Kim, Gwi Eon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1992-06-15

    Between August 1988 and December 1991, 24 patients with intracranial tumors were treated with stereotactic radiosurgery(RS) using a 10 MV linear accelerator at Severance Hospital, Yonsei University College of Medicine. There were 5 meningiomas, 3 craniopharyngiomas, 9 glial tumors, 2 solitary metastases, 2 acoustic neurinomas, 2 pineal tumors, and 1 non-Hodgkin Iymphoma. Ten patients were treated as primary treatment after diagnosis with stereotactic biopsy or neuroimaging study. Nine patients underwent RS for post-op. residual tumors and three patients as a salvage treatment for recurrence after external irradiation. Two patients received RS as a boost followed by fractionated conventional radiotherapy. Among sixteen patients who were followed more than 6 months with neuroimage, seven patients (2 meningiomas, 4 benign glial tumors, one non-Hodgkin lymphoma) showed complete response on neuroimage after RS and nine patients showed decreased tumor size. There was no acute treatment related side reaction. Late complications include three patients with symptomatic peritumoral braid edema and one craniopharyngioma with optic chiasmal injury. Through this early experience, we conclude that stereotactically directed single high doses of irradiation to the small intracranial tumors is effective for tumor control. However, in order to define the role of radiosurgery in the management of intracranial tumors, we should get the long-term results available to demonstrate the benefits versus potential complications of this therapeutic modality.

  7. Stereotactic radiosurgery using the gamma knife for acoustic neuromas

    International Nuclear Information System (INIS)

    Foote, Robert L.; Coffey, Robert J.; Swanson, Jerry W.; Harner, Stephen G.; Beatty, Charles W.; Kline, Robert W.; Stevens, Lorna N.; Hu, Theresa C.

    1995-01-01

    Purpose: To assess the efficacy and toxicity of stereotactic radiosurgery using the gamma knife for acoustic neuromas. Methods and Materials: Between January 1990 and January 1993, 36 patients with acoustic neuromas were treated with stereotactic radiosurgery using the gamma knife. The median maximum tumor diameter was 21 mm (range: 6-32 mm). Tumor volumes encompassed within the prescribed isodose line varied from 266 to 8,667 mm 3 (median: 3,135 mm 3 ). Tumors ≤ 20 mm in maximum diameter received a dose of 20 Gy to the margin, tumors between 21 and 30 mm received 18 Gy, and tumors > 30 mm received 16 Gy. The dose was prescribed to the 50% isodose line in 31 patients and to the 45%, 55%, 60%, 70%, and 80% isodose line in one patient each. The median number of isocenters per tumor was 5 (range: 1-12). Results: At a median follow-up of 16 months (range: 2.5-36 months), all patients were alive. Thirty-five patients had follow-up imaging studies. Nine tumors (26%) were smaller, and 26 tumors (74%) were unchanged. No tumor had progressed. The 1- and 2-year actuarial incidences of facial neuropathy were 52.2% and 66.5%, respectively. The 1- and 2-year actuarial incidences of trigeminal neuropathy were 33.7% and 58.9%, respectively. The 1- and 2-year actuarial incidence of facial or trigeminal neuropathy (or both) was 60.8% and 81.7%, respectively. Multivariate analysis revealed that the following were associated with the time of onset or worsening of facial weakness or trigeminal neuropathy: (a) patients five isocenters. The 1- and 2-year actuarial rates of preservation of useful hearing (Gardner-Robertson class I or II) were 100% and 41.7% ± 17.3, respectively. Conclusion: Stereotactic radiosurgery using the gamma knife provides short-term control of acoustic neuromas when a dose of 16 to 20 Gy to the tumor margin is used. Preservation of useful hearing can be accomplished in a significant proportion of patients

  8. Stereotactic radiotherapy and radiosurgery in pediatric patients: analysis of indications and outcome

    DEFF Research Database (Denmark)

    Mirza, Bilal; Mønsted, Anne; Jensen, Josephine Harding

    2010-01-01

    We describe indications, outcomes, and risk profiles of fractionated stereotactic radiotherapy (SRT) and single fraction "radiosurgery" (SRS) in pediatric patients compared to the adult population and evaluate the causal role of SRS and SRT in inducing new neurological complications....

  9. A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife

    International Nuclear Information System (INIS)

    Choi, Tae Jin; Kim, Jin Hee; Kim, Ok Bae

    1996-01-01

    Purpose : To get an acute steepness of dose gradients at outside the target volume in intracranial lesion and a less limitation of beam selection avoiding the high dose at normal brain tissue, this Photon Knife Radiosurgery System was developed in order to provide the three-dimensional dose distribution through the reconstruction of CT scan and the combined stereotactic tranmultiarc beam mode based on linear accelerator photon beam. Methods and Materials : This stereotactic radiosurgery, Photon Knife based on linear accelerator photon beam was provided the non-coplanar multiarc and trans-multiarc irradiations. The stereotactic trans-multiarc beam mode can be obtained from the patient position in decubitus. This study has provided the 3-dimensional isodose curve and anatomical structures with the surface rendering technique. Results : In this study, it shows that the dose distributions of stereotactic beam mode are significantly depended on the selected couch and gantry angle in same collimator size. Practical dose distribution of combined stereotactic trans-multiarc beam has shown a more small rim thickness than that of the non-coplanar multiarc beam mode in axial, sagittal and coronal plane in our study. 3-Dimensional dose line displayed with surface rendering of irregular target shape is helpful to determine the target dose and to predict the prognosis in follow-up radiosurgery. Conclusion : 3-Dimensional dose line displayed with surface rendering of irregular target shape is essential in stereotactic radiosurgery. This combined stereotactic trans-multiarc beam has shown a less limitation of the selection couch and gantry beam angles for the target surrounding critical organs. It has shown that the dose distribution of combined trans-multiarc beam greatly depended on the couch and gantry angles. In our experiments. the absorbed dose has been decreased to 27 % /mm in maximum at the interval of 50% to 80% of isodose line

  10. Is it sufficient to repeat LINEAR accelerator stereotactic radiosurgery in choroidal melanoma?

    Science.gov (United States)

    Furdova, A; Horkovicova, K; Justusova, P; Sramka, M

    One day session LINAC based stereotactic radiosurgery (SRS) at LINAC accelerator is a method of "conservative" attitude to treat the intraocular malignant uveal melanoma. We used model Clinac 600 C/D Varian (system Aria, planning system Corvus version 6.2 verification IMRT OmniPro) with 6 MeV X by rigid immobilization of the eye to the Leibinger frame. The stereotactic treatment planning after fusion of CT and MRI was optimized according to the critical structures (lens, optic nerve, also lens and optic nerve at the contralateral side, chiasm). The first plan was compared and the best plan was applied for therapy at C LINAC accelerator. The planned therapeutic dose was 35.0 Gy by 99 % of DVH (dose volume histogram). In our clinical study in the group of 125 patients with posterior uveal melanoma treated with SRS, in 2 patients (1.6 %) was repeated SRS indicated. Patient age of the whole group ranged from 25 to 81 years with a median of 54 TD was 35.0 Gy. In 2 patients after 5 year interval after stereotactic radiosurgery for uveal melanoma stage T1, the tumor volume increased to 50 % of the primary tumor volume and repeated SRS was necessary. To find out the changes in melanoma characteristics after SRS in long term interval after irradiation is necessary to follow up the patient by an ophthalmologist regularly. One step LINAC based stereotactic radiosurgery with a single dose 35.0 Gy is one of treatment options to treat T1 to T3 stage posterior uveal melanoma and to preserve the eye globe. In some cases it is possible to repeat the SRS after more than 5 year interval (Fig. 8, Ref. 23).

  11. Solid craniopharyngiomas treated by stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Backlund, E.-O.

    1979-01-01

    The radiological changes of solid craniopharyngiomas treated by stereotactic radiosurgery have been followed. Nine cases are considered, the patients having received gamma radiation treatment with a dose distribution permitting no part of the tumour to receive doses less than 2-3 Gy. Target doses were 20 to 50 Gy. Tumour shrinkage was registered and no complications which could be attributed with certainty to the irradiation were encountered. The results did not allow an optimal single dose to be determined with accuracy but vaguely indicated that lower doses than those used are sufficient for desired effect on the tumour without jeopardizing its surroundings. (Auth./C.F.)

  12. Effect of seeds of heavy charged particles of galactic cosmic radiation

    International Nuclear Information System (INIS)

    Maksimova, Y.N.

    1985-01-01

    The experiments were carried out on Lactuca sativa seeds exposed for 20, 66, 123 and 308 days in a biostack also containing physical detectors of heavy charged particles. The yield of aberrant cells and its dependence on the exposure time and the site where particles hit the object were measured. The cytogenetic examination demonstrated a significant difference between the seeds that were or were not hit by heavy charged particles. A significant contribution of galactic cosmic radiation to the radiobiological effect is indicated. The yield of aberrant cells as a function of the localization of heavy charged particles in the seed is established. The most sensitive target is the root meristem

  13. Stereotactic treatment. Definitions and literature overview

    International Nuclear Information System (INIS)

    Fontenla, D.P.

    2008-01-01

    The topics discussed include, among others, the following: Radiosurgery definitions; Stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT); Available uncertainties in SRS; Gamma knife; Linac-based SRS; Components of a radiosurgery system; Stereotactic hardware (brain lab); m3 linac attachment; Radiosurgery - clinical procedure; Cancer management; Rationale for SRT; Role of radiosurgery in the management of intracranial tumors; Indications for stereotactic SRS/SRT; Physical components required for SRS/SRT; Stereotactic patient set-up; Stereotactic CT scan for SRS; Physical components required for SRT: Relocatable head frame (GTC); Patient immobilization; Treatment planning system; Basic requirements for SRS dosimetry (Linac based); Stereotactic set-up QA (Linac); Stereotactic frames and QA; Beam dose measurements; Dose evaluation tools; Phantoms. (P.A.)

  14. Effect of heavy charged particles of galactic cosmic radiation on seeds

    International Nuclear Information System (INIS)

    Maksimova, E.N.

    1985-01-01

    The experiments were carried out on Lactuca sativa seeds exposed for 20, 66, 123 and 308 days in a biostack also containing physical detectors of heavy charged particles. The puppose of the experiments was to measure the yield of abberrant cells and its dependence on the exposure time and the site where particles hit the object. The cytogenetic examination demonstrated a significant difference between the seeds that were or were not hit by heavy charged particles. This is indicative of a significant contribution of galactic cosmic radiation to the radiobiological effect. The yield of aberrant cells as a function of the localization of heavy charged particles in the seed was established. The most sensitive target was the root meristem

  15. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance.

    Science.gov (United States)

    Gagnon, Jean-Christophe; Thériault, Dany; Guillot, Mathieu; Archambault, Louis; Beddar, Sam; Gingras, Luc; Beaulieu, Luc

    2012-01-01

    To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S(c,p)) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 × 10 cm(2) field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S(c,p) within 1.4% and 0.7% for 5 and 35 mm diameter cone, respectively. Furthermore

  16. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Gagnon, Jean-Christophe; Theriault, Dany; Guillot, Mathieu; Archambault, Louis; Beddar, Sam; Gingras, Luc; Beaulieu, Luc [Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada); Department of Radiation Physics, Unit 94, University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030 (United States); Departement de Physique, de Genie Physique et d' Optique, Universite Laval, Quebec, Quebec G1K 7P4 (Canada) and Departement de Radio-Oncologie, Hotel-Dieu de Quebec, Centre Hospitalier Universitaire de Quebec, Quebec G1R 2J6 (Canada)

    2012-01-15

    Purpose: To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. Methods: The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S{sub c,p}) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Results: Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 x 10 cm{sup 2} field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S{sub c,p} within 1.4% and 0.7% for 5 and 35 mm diameter cone

  17. Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance

    International Nuclear Information System (INIS)

    Gagnon, Jean-Christophe; Theriault, Dany; Guillot, Mathieu; Archambault, Louis; Beddar, Sam; Gingras, Luc; Beaulieu, Luc

    2012-01-01

    Purpose: To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. Methods: The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S c,p ) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Results: Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 x 10 cm 2 field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S c,p within 1.4% and 0.7% for 5 and 35 mm diameter cone, respectively

  18. Hypofractionated Stereotactic Radiosurgery in a Large Bilateral Thalamic and Basal Ganglia Arteriovenous Malformation

    Directory of Open Access Journals (Sweden)

    Janet Lee

    2013-01-01

    Full Text Available Purpose. Arteriovenous malformations (AVMs in the basal ganglia and thalamus have a more aggressive natural history with a higher morbidity and mortality than AVMs in other locations. Optimal treatment—complete obliteration without new neurological deficits—is often challenging. We present a patient with a large bilateral basal ganglia and thalamic AVM successfully treated with hypofractionated stereotactic radiosurgery (HFSRS with intensity modulated radiotherapy (IMRT. Methods. The patient was treated with hypofractionated stereotactic radiosurgery to 30 Gy at margin in 5 fractions of 9 static fields with a minimultileaf collimator and intensity modulated radiotherapy. Results. At 10 months following treatment, digital subtraction angiography showed complete obliteration of the AVM. Conclusions. Large bilateral thalamic and basal ganglia AVMs can be successfully treated with complete obliteration by HFSRS with IMRT with relatively limited toxicity. Appropriate caution is recommended.

  19. Radiation tolerance of normal temporal bone structures: implications for gamma knife stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Linskey, Mark E.; Johnstone, Peter A.

    2003-01-01

    Popular current thought states that hearing loss and facial weakness after radiosurgery of vestibular schwannomas is a function of cranial nerve damage. Although this may be true in some cases, the middle and inner ear contain rich networks of other sensitive structures that are at risk after radiotherapy and that may contribute to toxicity afterward. We reviewed the limited reported data regarding radiation tolerance of external, middle, and inner ear structures, and perspectives for therapy with gamma knife stereotactic radiosurgery are addressed

  20. Stereotactic Radiosurgery versus Natural History in Patients with Growing Vestibular Schwannomas.

    Science.gov (United States)

    Tu, Albert; Gooderham, Peter; Mick, Paul; Westerberg, Brian; Toyota, Brian; Akagami, Ryojo

    2015-08-01

    Objective To describe our experience with stereotactic radiosurgery and its efficacy on growing tumors, and then to compare this result with the natural history of a similar cohort of non-radiation-treated lesions. Study Design A retrospective chart review and cohort comparison. Methods The long-term control rates of patients having undergone radiosurgery were collected and calculated, and this population was then compared with a group of untreated patients from the same period of time with growing lesions. Results A total of 61 patients with growing vestibular schwannomas treated with radiosurgery were included. After a mean of 160 months, we observed a control rate of 85.2%. When compared with a group of 36 patients with growing tumors who were yet to receive treatment (previously published), we found a corrected control rate or relative risk reduction of only 76.8%. Conclusion Radiosurgery for growing vestibular schwannomas is less effective than previously reported in unselected series. Although radiosurgery still has a role in managing this disease, consideration should be given to the actual efficacy that may be calculated when the natural history is known. We hope other centers will similarly report their experience on this cohort of patients.

  1. Stereotactic gamma radiosurgery of pineal and related tumors

    International Nuclear Information System (INIS)

    Kobayashi, Tatsuya; Mori, Yoshimasa; Yamada, Yasushi; Kida, Yoshihisa

    2001-01-01

    The role of gamma radiosurgery as an additional therapy after conventional treatments for pineal and related tumors was studied in 30 out of 33 cases with a mean follow-up of 23.3 months. Overall results showed that complete response (CR) was obtained in 8 cases (26.7%) and response rate was 73.3%. However, enlargement of the tumors was noted in 8 cases, of which 7 (23.3%) died of tumor progression (PG). Germinomas and pineocytomas showed higher response and control rates of 100%, and no tumor enlargement or death occurred after gamma knife treatment. In germinoma with STGC (syncytiotrophoblastic giant cell) which has been thought to have intermediate prognosis, two cases showed partial response (PR), but another died from progression of the disease. Malignant germ cell tumors and pineoblastomas showed unfavorable response and prognosis; the response and progression rates were 50%. However, complete response was obtained in 3 cases (25%) after gamma radiosurgery. Gamma knife was the initial treatment in three cases without pathological diagnosis in which one obtained CR and two showed partial response (PR). Stereotactic gamma radiosurgery is expected to be an effective and novel treatment for pineal and related tumors not only as an adjuvant, but also as an initial therapy. (author)

  2. Motion detection system with GPU acceleration for stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Yamakawa, Takuya; Ogawa, Koichi; Iyatomi, Hitoshi; Usui, Keisuke; Kunieda, Etsuo; Shigematsu, Naoyuki

    2012-01-01

    Stereotactic radiosurgery is a non-invasive method for the treatment of tumors that employs a narrow, high-energy X-ray beam. In this form of therapy, the target region is intensively irradiated with the narrow beam, and any unexpected patient motion may therefore lead to undesirable irradiation of neighboring normal tissues and organs. To overcome this problem, we propose a contactless motion detection system with three USB cameras for use in stereotactic radiosurgery of the head and neck. In our system, the three cameras monitor images of the patient's nose and ears, and patient motion is detected using a template-matching method. If patient motion is detected, the system alerts the radiologist to turn off the beam. We reduced the effects of variations in the lighting in the irradiation room by employing USB cameras sensitive to infrared light. To detect movement in the acquired images, we use a template-matching method that is realized with general-purpose computing-on-graphics processing units. In this paper, we present an outline of our proposed motion detection system based on monitoring of images of the patient acquired with infrared USB cameras and a template-matching method. The performance of the system was evaluated under the same conditions as those used in actual radiation therapy of the head and neck. (author)

  3. The Physician Tendency in Stereotactic Radiosurgery Dose Prescription in Benign Intracranial Tumor at dr. Cipto Mangunkusumo National Hospital, Jakarta

    Directory of Open Access Journals (Sweden)

    Henry Kodrat

    2016-09-01

    Full Text Available Stereotactic radiosurgery (SRS is one of the treatment modalities for benign intra-cranial tumor, especiallyfor the tumor located next to the critical neural structure. The prescribed dose for radiosurgery depends onthe maximal tumor diameter and surrounding normal tissue tolerance dose. This cross sectional study wasconducted to evaluate the physician’s tendency in radiosurgery dose prescription. We observed treatmentplanning data of 32 patients with benign intra-cranial tumor, which had been treated with SRS at Dr. CiptoMangunkusumo National Hospital in 2009-2010. The peripheral dose, organ at risk (OAR dose limitiationand maximum tumor diameter were recorded. We compared our SRS dose with dose limitation, whichallowed safer dosing based on maximal tumor diameter perspective and the nearest OAR dose constraint.From maximal tumor diameter perspective, we prescribed mean±SD radiosurgery doses, which were11.63±2.21Gy, 10.21±1.29Gy and 9.88±1.07Gy for the tumor size ≤2cm, 2.01-3cm and 3,01-4cm respectively.Our radiosurgery dose was the lowest than dose limitation based on the nearest OAR perspective, followedby maximal tumor diameter perspective. It was concluded that radiosurgery dose had the tendency to beinfluenced by surrounding healthy tissue tolerance rather than maximal tumor diameter. Keywords: stereotactic, radiosurgery, benign tumor, dose.   Kecenderungan Dokter dalam Menentukan Dosis StereotacticRadiosurgery untuk Tumor Jinak Intrakranial diRSUP Nasional dr. Cipto Mangunkusumo, Jakarta Abstrak Stereotactic radiosurgery (SRS merupakan salah satu modalitas pengobatan tumor jinak intra-kranialterutama untuk tumor yang berdekatan dengan struktur saraf penting. Penentuan dosis pada radiosurgerytergantung pada diameter tumor maksimal dan dosis toleransi jaringan sehat sekitarnya. Penelitian inidilakukan untuk mengevaluasi kecenderungan dokter dalam menentukan dosis radiosurgery. Penelitian crosssectional ini mengevaluasi data

  4. Radiobiology of heavy charged particles

    International Nuclear Information System (INIS)

    Kraft, G.

    1996-11-01

    The increase in the biological efficiency is the major motivation to use ions heavier than protons for therapy. Therefore, the detailed understanding of the radiobiological potential of heavy ions like carbon or oxygen is the basic condition of a proper application of these ions in therapy. But also for the lightest ion, the proton, evidence accumulates that changes in the radiobiological properties at the end of the particle range influence the therapeutic effect. Compared to sparsely ionizing radiation heavy charged particles exhibit a different physical interaction with the target material: The highly charged ions interact mostly via Coulomb forces with the electrons of the target material producing a track of ionizations and highly kinetic electrons along the path of the primary ion. In these tracks damage to the biological structures like the DNA occurs in a non stochastic, but spatially correlated way yielding a dramatic variation in the biological severity of the created damage. In cell-experiments the variation in the relative biological efficiency has been measured for many biological reactions like cell inactivation, chromosome aberrations and DNA damage. An overview on the inactivation data will be given and theoretical approaches will be discussed and compared to experimental data. (orig.)

  5. Radiosurgery of arteriovenous malformations

    International Nuclear Information System (INIS)

    Kawamoto, Shunsuke

    1994-01-01

    Steiner has first published a report of a case of cerebral arteriovenous malformation (AVM) treated with gamma knife radiosurgery in 1972. Since the mid-1980s, radiosurgery has increasingly received much attention. There have already been more than 6,000 radiosurgically treated AVM cases. This article reviews radiosurgery in the context of the following: (1) radiosurgery according to gamma knife, linear accelerator, heavy-charged particle Bragg-peak radiation and neutron; (2) therapeutic outcome in view of angiographically proven complete obliteration (CO) of AVM, including the time required for CO and factors regulating CO (such as the volume of AVM, radiation doses, correlation between the volume of AVM and radiation doses, age, and site of AVM), histopathological findings, and clinical complaints (such as headache and epilepsy) after radiosurgery; (3) bleeding after radiosurgery; (4) complications (including angiography-related complications, those immediately after radiosurgery, delayed complications, factors influencing delayed complications, and endocrine or growth retardation); (5) other problems (such as radiation doses, follow-up strategy, approaches to giant AVMs, and repeat irradiation); (6) indication of radiosurgery for lesions other than brain stem, and lesions of the mid-brain, pons and bulb. (N.K.) 134 refs

  6. Linear accelerator based stereotactic radiosurgery with micro multi-leaf collimator : technological advancement in precision radiotherapy

    International Nuclear Information System (INIS)

    Dayananda, S.; Kinhikar, R.A.; Saju, Sherley; Deshpande, D.D.; Jalali, R.; Sarin, R.; Shrivastava, S.K.; Dinshaw, K.A.

    2003-01-01

    Stereotactic Radiosurgery (SRS) is an advancement on precision radiotherapy, in which stereo tactically guided localized high dose is delivered to the lesion (target) in a single fraction, while sparing the surrounding normal tissue. Radiosurgery has been used to treat variety of benign and malignant lesions as well as functional disorders in brain such as arteriovenous malformation (AVM), acoustic neuroma, solitary primary brain tumor, single metastasis, pituitary adenoma etc

  7. Enhanced intrinsic radiosensitivity after treatment with stereotactic radiosurgery for an acoustic neuroma

    International Nuclear Information System (INIS)

    Adams, Gerard; Martin, Olga A.; Roos, Daniel E.; Lobachevsky, Pavel N.; Potter, Andrew E.; Zacest, Andrew C.; Bezak, Eva; Bonner, William M.; Martin, Roger F.; Leong, Trevor

    2012-01-01

    Enhanced radiosensitivity is an uncommon phenomenon attributable to deficient DNA repair after radiotherapy which can be assessed with the γ-H2AX assay. Reports of radiosensitivity after stereotactic radiosurgery (SRS) are uncommon. We describe a case where the clinical, radiological and laboratory findings suggest enhanced radiosensitivity after SRS for an acoustic neuroma.

  8. The use of single fraction Leksell stereotactic radiosurgery in the treatment of uveal melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Rennie, I. [Univ. of Sheffield, Dept. of Ophthalmology and Orthoptics (United Kingdom); Forster, D.; Kemeny, A. [Royal Hallamshire Hospital, Dept. of Neurosurgery (United Kingdom); Walton, L. [Royal Hallamshire Hospital, Dept. of Medical Physics (United Kingdom); Kunkler, I. [Weston Park Hospital, Dept. of Radiotherapy, Sheffield (United Kingdom)

    1996-11-01

    Fourteen patients with posterior uveal melanomas were treated using single fraction stereotactic radiosurgery. In each case a dose of 70 Gy was administered to the periphery of the tumour. Regression of the tumour has been observed in 13 patients, whilst the lesion has remained unchanged in one patient. The visual acuity has deteriorated in all 14 patients. Significant radiation induced adverse reactions were noted in 13 patients and include; retinopathy, optic neuropathy, rubeosis iridis, and secondary glaucoma. Two patients have required enucleation because of intractable rubeotic glaucoma. One patient has died from proven metastases. Although stereotactic radiosurgery appears to be a practical and effective method of treating uveal melanomas, its usefulness is limited by a high incidence of radiation induced adverse reactions. Further works is required to refine the current treatment protocol and establish an optimal prescription dose. (au) 30 refs.

  9. The use of single fraction Leksell stereotactic radiosurgery in the treatment of uveal melanoma

    International Nuclear Information System (INIS)

    Rennie, I.; Forster, D.; Kemeny, A.; Walton, L.; Kunkler, I.

    1996-01-01

    Fourteen patients with posterior uveal melanomas were treated using single fraction stereotactic radiosurgery. In each case a dose of 70 Gy was administered to the periphery of the tumour. Regression of the tumour has been observed in 13 patients, whilst the lesion has remained unchanged in one patient. The visual acuity has deteriorated in all 14 patients. Significant radiation induced adverse reactions were noted in 13 patients and include; retinopathy, optic neuropathy, rubeosis iridis, and secondary glaucoma. Two patients have required enucleation because of intractable rubeotic glaucoma. One patient has died from proven metastases. Although stereotactic radiosurgery appears to be a practical and effective method of treating uveal melanomas, its usefulness is limited by a high incidence of radiation induced adverse reactions. Further works is required to refine the current treatment protocol and establish an optimal prescription dose. (au) 30 refs

  10. The lazaroid U74389G protects normal brain from stereotactic radiosurgery-induced radiation injury

    International Nuclear Information System (INIS)

    Buatti, John M.; Friedman, William A.; Theele, Daniel P.; Bova, Francis J.; Mendenhall, William M.

    1996-01-01

    Purpose: To test an established model of stereotactic radiosurgery-induced radiation injury with pretreatments of either methylprednisolone or the lazaroid U74389G. Methods and Materials: Nine cats received stereotactic radiosurgery with a linear accelerator using an animal radiosurgery device. Each received a dose of 125.0 Gy prescribed to the 84% isodose shell to the anterior limb of the right internal capsule. One animal received no pretreatment, two received citrate vehicle, three received 30 mg/kg of methylprednisolone, and three received 5 mg/kg of U74389G. After irradiation, the animals had frequent neurologic examinations, and neurologic deficits developed in all of them. Six months after the radiation treatment, the animals were anesthetized, and had gadolinium-enhanced magnetic resonance (MR) scans, followed by Evans blue dye perfusion, euthanasia, and brain fixation. Results: Magnetic resonance scans revealed a decrease in the size of the lesions from a mean volume of 0.45 ± 0.06 cm 3 in the control, vehicle-treated, and methylprednisolone-treated animals to 0.22 ± 0.14 cm 3 in the U74389G-treated group. The scans also suggested the absence of necrosis and ventricular dilatation in the lazaroid-treated group. Gross pathology revealed that lesions produced in the untreated, vehicle-treated, and methylprednisolone-treated cats were similar and were characterized by a peripheral zone of Evans blue dye staining with a central zone of a mature coagulative necrosis and focal hemorrhage. However, in the U74389G-treated animals, the lesions were found to have an area of Evans blue dye staining, but lacked discrete areas of necrosis and hemorrhage. Conclusion: These results suggest that the lazaroid U74389G protects the normal brain from radiation injury produced by stereotactic radiosurgery

  11. Stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Souhami, L.; Podgorsak, E.B.

    1990-01-01

    Radiosurgery is an irradiation technique which over the last few years became frequently utilized. Because of the sophisticated and expensive equipments originally required, its use was restricted initially to a few and specialized centers in the world. The introduction of new techniques based on isocentric linear accelerators made now this therapy available to the major radiotherapy centers. Some of the essential requirements for radiosurgery include an accurate determination of the target volume, 3-dimensional dose calculation, accurate dose delivery to the target volume and a sharp dose fall-off outside the target volume. In this paper, we discuss the principles, the indications, some of the techniques, and the initial therapeutics results with radiosurgery. (author) [pt

  12. Stereotactic radiosurgery for acoustic neuroma: a Canadian perspective

    International Nuclear Information System (INIS)

    Ross, I.B.; Tator, C.H.

    1998-01-01

    Stereotactically delivered radiation is now an accepted treatment for patients with acoustic neuroma. In some cases, patient preference may be the reason for its selection, while in others neurosurgeons may select it for patients who are elderly or have significant risk factors for conventional surgery. The majority of patients with acoustic neuroma treatment with stereotactic radiosurgery have been treated with the Gamma Knife, with follow ups of over 25 years in some instances. Other radiosurgical modalities utilizing the linear accelerator have been developed and appear promising, but there is no long-term: follow up. Canada does not possess a Gamma Knife facility, and its government-funded hospital and medical insurance agencies have made it difficult for patients to obtain reimbursement for Gamma Knife treatments in other countries. We review the literature to date on the various forms of radiation treatment for acoustic neuroma and discuss the current issues facing physicians and patients in Canada who wish to obtain their treatment of choice. (author)

  13. Stereotactic Radiosurgery for Benign (World Health Organization Grade I) Cavernous Sinus Meningiomas-International Stereotactic Radiosurgery Society (ISRS) Practice Guideline: A Systematic Review.

    Science.gov (United States)

    Lee, Cheng-Chia; Trifiletti, Daniel M; Sahgal, Arjun; DeSalles, Antonio; Fariselli, Laura; Hayashi, Motohiro; Levivier, Marc; Ma, Lijun; Álvarez, Roberto Martínez; Paddick, Ian; Regis, Jean; Ryu, Samuel; Slotman, Ben; Sheehan, Jason

    2018-03-15

    Stereotactic radiosurgery (SRS) has become popular as a standard treatment for cavernous sinus (CS) meningiomas. To summarize the published literature specific to the treatment of CS meningioma with SRS found through a systematic review, and to create recommendations on behalf of the International Stereotactic Radiosurgery Society. Articles published from January 1963 to December 2014 were systemically reviewed. Three electronic databases, PubMed, EMBASE, and The Cochrane Central Register of Controlled Trials, were searched. Publications in English with at least 10 patients (each arm) were included. Of 569 screened abstracts, a total of 49 full-text articles were included in the analysis. All studies were retrospective. Most of the reports had favorable outcomes with 5-yr progression-free survival (PFS) rates ranging from 86% to 99%, and 10-yr PFS rates ranging from 69% to 97%. The post-SRS neurological preservation rate ranged from 80% to 100%. Resection can be considered for the treatment of larger (>3 cm in diameter) and symptomatic CS meningioma in patients both receptive to and medically eligible for open surgery. Adjuvant or salvage SRS for residual or recurrent tumor can be utilized depending on factors such as tumor volume and proximity to adjacent critical organs at risk. The literature is limited to level III evidence with respect to outcomes of SRS in patients with CS meningioma. Based on the observed results, SRS offers a favorable benefit to risk profile for patients with CS meningioma.

  14. Physical aspects of heavy charged particle beams for radiotherapy

    International Nuclear Information System (INIS)

    Kawashima, Katsuhiro

    1989-01-01

    Physical properties of heavy ion beams are discussed to improve the physical dose distributions in view of radiotherapy. Preservation of the structural and functional integrity of adjacent normal tissue is required to achieve great probability of tumor control. This will be accomplished with the reduction of irradiated volume of normal tissues and with greater relative biological effectiveness (RBE) on tumor cells than that on surrounding normal cells. This suggests the use of heavy ion beams as new source of radiation that increases the therapeutic ratio. The basis of the improvement in the physical dose distribution by use of heavy charged particles is due to the finite range of the beams and to the less multiple coulomb scattering of the particles having a heavier atomic mass than proton. The depth dose distributions and dose profiles of heavy particle beams are discussed in this article. The lateral sharpness of heavy charged particles is comparable to the penumbra of high energy photon and electron beams and is not of clinical concern due to less coulomb scattering of heavy ions to lateral direction in traversing a medium. The dose gradient at the end of range of primary beam is dependent upon the energy spread and range straggling of the particles. The magnitude of range straggling is nearly proportional to the range and inversely proportional to the inverse square root of the particle mass. Heavy ion beams also undergo nuclear interactions, in which the primary beam may produce lower atomic number particles. Therefore, the dose beyond the Bragg peak is due to those fragments. Fragmentation increases as a function of the atomic mass to the 2/3 power and with the energy of the particles. Thus, the production of fragments diminishes the depth dose advantages of heavy ions. The choice of ion for radiotherapy may depend on evaluation of important parameter for tumor control. (J.P.N.)

  15. Imaging of arteriovenous malformation following stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Tranchida, J.V.; Mehall, C.J.; Slovis, T.L.; Lis-Planells, M.

    1997-01-01

    Background. Stereotactic radiosurgery allows for a high dose of focused radiation to be delivered to a small lesion such as an arteriovenous malformation (AVM). The clinical change and brain response over time to this localized high-dose radiation can be quite striking. Objective. The objective of this study to describe and analyse the imaging changes following radiotherapy for AVMs. Materials and methods. The clinical presentation and the imaging changes following radiotherapy in two patients were studied over the course of 1-2 years. Results. The imaging findings include diffuse low attenuation and contrast enhancement on CT. High-signal lesions were apparent on T2-weighted MR images with prominent contrast enhancement on T1-weighted images. Ring enhancement occurred over time. While new changes appeared over 12 months, these changes diminished during the second year. Conclusion. Radiotherapy induces inflammatory changes that are generally reversible but can lead to parenchymal destruction. These imaging changes are often nonspecific and therefore must be interpreted in light of clinical symptomatology and the time course since treatment. These patients should receive routine MR imaging within 3 months after radiosurgery with follow-up imaging at 6, 12, and 18 months. (orig.). With 8 figs

  16. Stereotactic radiosurgery for the treatment of mesial temporal lobe epilepsy.

    Science.gov (United States)

    Feng, E-S; Sui, C-B; Wang, T-X; Sun, G-L

    2016-12-01

    Stereotactic radiosurgery (RS) is a potential option for some patients with temporal lobe epilepsy (TLE). The aim of this meta-analysis was to determine the pooled seizure-free rate and the time interval to seizure cessation in patients with lesions in the mesial temporal lobe, and who were eligible for either stereotactic or gamma knife RS. We searched the Medline, Cochrane, EMBASE, and Google Scholar databases using combinations of the following terms: RS, stereotactic radiosurgery, gamma knife, and TLE. We screened 103 articles and selected 13 for inclusion in the meta-analysis. Significant study heterogeneity was detected; however, the included studies displayed an acceptable level of quality. We show that approximately half of the patients were seizure free over a follow-up period that ranged from 6 months to 9 years [pooled estimate: 50.9% (95% confidence interval: 0.381-0.636)], with an average of 14 months to seizure cessation [pooled estimate: 14.08 months (95% confidence interval: 11.95-12.22 months)]. Nine of 13 included studies reported data for adverse events (AEs), which included visual field deficits and headache (the two most common AEs), verbal memory impairment, psychosis, psychogenic non-epileptic seizures, and dysphasia. Patients in the individual studies experienced AEs at rates that ranged from 8%, for non-epileptic seizures, to 85%, for headache. Our findings indicate that RS may have similar or slightly less efficacy in some patients compared with invasive surgery. Randomized controlled trials of both treatment regimens should be undertaken to generate an evidence base for patient decision-making. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Early experiences of planning stereotactic radiosurgery using 3D printed models of eyes with uveal melanomas

    Directory of Open Access Journals (Sweden)

    Furdová A

    2017-01-01

    Full Text Available Alena Furdová,1 Miron Sramka,2 Andrej Thurzo,3 Adriana Furdová3 1Department of Ophthalmology, Faculty of Medicine, Comenius University, 2Department of Stereotactic Radiosurgery, St Elisabeth Cancer Inst and St Elisabeth University College of Health and Social Work, 3Department of Simulation and Virtual Medical Education, Faculty of Medicine, Comenius University, Bratislava, Slovak Republic Objective: The objective of this study was to determine the use of 3D printed model of an eye with intraocular tumor for linear accelerator-based stereotactic radiosurgery.Methods: The software for segmentation (3D Slicer created virtual 3D model of eye globe with tumorous mass based on tissue density from computed tomography and magnetic resonance imaging data. A virtual model was then processed in the slicing software (Simplify3D® and printed on 3D printer using fused deposition modeling technology. The material that was used for printing was polylactic acid.Results: In 2015, stereotactic planning scheme was optimized with the help of 3D printed model of the patient’s eye with intraocular tumor. In the period 2001–2015, a group of 150 patients with uveal melanoma (139 choroidal melanoma and 11 ciliary body melanoma were treated. The median tumor volume was 0.5 cm3 (0.2–1.6 cm3. The radiation dose was 35.0 Gy by 99% of dose volume histogram.Conclusion: The 3D printed model of eye with tumor was helpful in planning the process to achieve the optimal scheme for irradiation which requires high accuracy of defining the targeted tumor mass and critical structures. Keywords: 3D printing, uveal melanoma, stereotactic radiosurgery, linear accelerator, intraocular tumor, stereotactic planning scheme

  18. Radiobiology with heavy charged particles: a historical review

    International Nuclear Information System (INIS)

    Skarsgard, L.D.

    1997-01-01

    The presentation will attempt to briefly review some of radiobiological data on the effects of heavy charged particles and to discuss the influence of those studies on the clinical application which followed. (orig./MG)

  19. Radiobiology with heavy charged particles: a historical review

    Energy Technology Data Exchange (ETDEWEB)

    Skarsgard, L D [Dept. of Medical Biophysics, B.C. Cancer Research Centre and TRIUMF, Vancouver (Canada)

    1997-09-01

    The presentation will attempt to briefly review some of radiobiological data on the effects of heavy charged particles and to discuss the influence of those studies on the clinical application which followed. (orig./MG)

  20. Conformity of LINAC-Based Stereotactic Radiosurgery Using Dynamic Conformal Arcs and Micro-Multileaf Collimator

    International Nuclear Information System (INIS)

    Hazard, Lisa J.; Wang, Brian; Skidmore, Thomas B.; Chern, Shyh-Shi; Salter, Bill J.; Jensen, Randy L.; Shrieve, Dennis C.

    2009-01-01

    Purpose: To assess the conformity of dynamic conformal arc linear accelerator-based stereotactic radiosurgery and to describe a standardized method of isodose surface (IDS) selection. Methods and Materials: In 174 targets, the conformity index (CI) at the prescription IDS used for treatment was calculated as CI = (PIV/PVTV)/(PVTV/TV), where TV is the target volume, PIV (prescription isodose volume) is the total volume encompassed by the prescription IDS, and PVTV is the TV encompassed by the IDS. In addition, a 'standardized' prescription IDS (sIDS) was chosen according to the following criteria: 95% of the TV was encompassed by the PIV and 99% of TV was covered by 95% of the prescription dose. The CIs at the sIDS were also calculated. Results: The median CI at the prescription IDS and sIDS was 1.63 and 1.47, respectively (p < 0.001). In 132 of 174 cases, the volume of normal tissue in the PIV was reduced by the prescription to the sIDS compared with the prescription IDS, in 20 cases it remained unchanged, and in 22 cases it was increased. Conclusion: The CIs obtained with linear accelerator-based stereotactic radiosurgery are comparable to those previously reported for gamma knife stereotactic radiosurgery. Using a uniform method to select the sIDS, adequate target coverage was usually achievable with prescription to an IDS greater than that chosen by the treating physician (prescription IDS), providing sparing of normal tissue. Thus, the sIDS might aid physicians in identifying a prescription IDS that balances coverage and conformity

  1. The role of stereotactic radiosurgery in the treatment of malignant skull base tumors

    International Nuclear Information System (INIS)

    Miller, Robert C.; Foote, Robert L.; Coffey, Robert J.; Gorman, Deborah A.; Earle, John D.; Schomberg, Paula J.; Kline, Robert W.

    1997-01-01

    Purpose: To determine the efficacy and toxicity of stereotactic radiosurgery in the treatment of malignant skull base tumors. Methods and Materials: Thirty-two patients with 35 newly diagnosed or recurrent malignant skull base tumors ≤33.5 cm 3 were treated using the Leksell Gamma unit. Tumor histologies included: adenoid cystic carcinoma, basal cell carcinoma, chondrosarcoma, chordoma, nasopharyngeal carcinoma, osteogenic sarcoma, and squamous cell carcinoma. Results: After a median follow-up of 2.3 years, 83% ± 15% (±95% confidence interval) of patients experienced a symptomatic response to treatment. Local control at the skull base was 95 ± 9% at 2 years and 78 ± 23% at 3 years. Local-regional control above the clavicles was 75 ± 15% at 1 year and 51 ± 20% at 2 years. Overall and cause specific survival were identical, 82 ± 13% at 1 year, 76 ± 14% at 2 years, and 72 ± 16% at 3 years. One patient developed a radiation-induced optic neuropathy 12 months after radiosurgery. Conclusion: Stereotactic radiosurgery using the Leksell Gamma Unit can provide durable tumor control and symptomatic relief with acceptable toxicity in the majority of patients with malignant tumors 4 cm or less in size involving the skull base. Further evaluation of more patients with longer follow-up is warranted

  2. Single-fraction vs. fractionated linac-based stereotactic radiosurgery for vestibular schwannoma: a single-institution study

    NARCIS (Netherlands)

    Meijer, O. W. M.; Vandertop, W. P.; Baayen, J. C.; Slotman, B. J.

    2003-01-01

    PURPOSE: In this single-institution trial, we investigated whether fractionated stereotactic radiation therapy is superior to single-fraction linac-based radiosurgery with respect to treatment-related toxicity and local control in patients with vestibular schwannoma. METHODS AND MATERIALS: All 129

  3. Clinical experience of stereotactic radiosurgery at a linear accelerator for intraocular melanoma.

    Science.gov (United States)

    Furdova, Alena; Sramka, Miron; Chorvath, Martin; Kralik, Gabriel; Furda, Robert; Gregus, Michal

    2017-10-01

    Long-term results with linear accelerator LINAC-based stereotactic radiosurgery for intraocular uveal malignant melanoma were assessed. A retrospective study was carried out of patients with uveal melanoma after a 1-day session stereotactic radiosurgery at LINAC in Slovakia. In the period 2001-2015, a group of 150 patients with uveal melanoma (139 choroidal melanoma, 11 ciliary body melanoma) was treated. The median tumor volume at baseline was 0.5 cm (with range from 0.2 to 1.6 cm). Tumors ranged in size from 2.4 to 20.8 mm in basal diameter and from 2.0 to 18.3 mm in thickness. The therapeutic dose was 35.0 Gy by 99% of dose volume histogram. Older age at treatment was correlated with the largest basal tumor diameter, tumor thickness, and TNM stage. The survival after stereotactic irradiation was 96% in 1 year, 93% in 2 years, 84% in 5 years, 80% in 7 years, and 53% in 11 years. In 20 (13.3%) patients, secondary enucleation was necessary because of complications (secondary glaucoma). Enucleation-free interval ranged from 1 to 6 years. The median age at death was lower (65.7 years) for patients who died from metastatic disease than for those who died from any other cause (75.0 years). Survival rates at 5-year intervals and the need for secondary enucleation because of complications after linear accelerator irradiation are comparable to other techniques.

  4. Technical Note: Dose gradients and prescription isodose in orthovoltage stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Fagerstrom, Jessica M.; Bender, Edward T.; Culberson, Wesley S.

    2016-01-01

    Purpose: The purpose of this work is to examine the trade-off between prescription isodose and dose gradients in orthovoltage stereotactic radiosurgery. Methods: Point energy deposition kernels (EDKs) describing photon and electron transport were calculated using Monte Carlo methods. EDKs were generated from 10  to 250 keV, in 10 keV increments. The EDKs were converted to pencil beam kernels and used to calculate dose profiles through isocenter from a 4π isotropic delivery from all angles of circularly collimated beams. Monoenergetic beams and an orthovoltage polyenergetic spectrum were analyzed. The dose gradient index (DGI) is the ratio of the 50% prescription isodose volume to the 100% prescription isodose volume and represents a metric by which dose gradients in stereotactic radiosurgery (SRS) may be evaluated. Results: Using the 4π dose profiles calculated using pencil beam kernels, the relationship between DGI and prescription isodose was examined for circular cones ranging from 4 to 18 mm in diameter and monoenergetic photon beams with energies ranging from 20 to 250 keV. Values were found to exist for prescription isodose that optimize DGI. Conclusions: The relationship between DGI and prescription isodose was found to be dependent on both field size and energy. Examining this trade-off is an important consideration for designing optimal SRS systems.

  5. Treatment of arteriovenous malformations with stereotactic radiosurgery employing both magnetic resonance angiography and standard angiography as a database

    International Nuclear Information System (INIS)

    Petereit, D.; Mehta, M.; Turski, P.; Levin, A.; Strother, C.; Mistretta, C.; Mackie, R.; Gehring, M.; Kubsad, S.; Kinsella, T.

    1993-01-01

    Twenty-one arteriovenous malformations were prospectively evaluated using magnetic resonance angiography, compare it to stereotactic angiography, employ magnetic resonance angiography in follow-up, and semiquanitfy flow. A correlative evaluation between flow and response to stereotactic radiosurgery was carried out. Phase contrast angiograms were obtained at flow velocities of 400, 200, 100, 60 and 20 cm/sec. The fractionated velocities provided images that selectively demonstrated the arterial and venous components of the arteriovenous malformations. Qualitative assessment of the velocity within the arteriovenous malformations and the presence of fistulae were also determined by multiple velocity images. In addition, 3-dimensional time-of-flight magnetic resonance angiograms were obtained to define the exact size and shape of the nidus. This technique also permitted evaluation of the nidus and feeding arteries for the the presence of low flow aneurysms. Correlation between the two imaging modalities was carried out by subjective and semiquantitative estimation of flow velocity and estimation of nidus size. The following velocity parameters were employed: fast, intermediate, slow, and none. Early analysis suggests that slower flowing arteriovenous malformations may obliterate faster after stereotactic radiosurgery an flow parameters should be employed to predict response. In conclusion, magnetic resonance angiography permits semiquantitative flow velocity assessment and may therefore be superior to stereotactic angiography. An additional advantage of magnetic resonance angiography is the generation of serial transverse images which can replace the conventional CT scan employed for stereotactic radiosurgery treatment planning. A single diagnostic test may therefore be used for diagnosis, radiosurgical treatment planning, follow-up, and treatment selection by identifying patients likely to respond early to radiosurgical management

  6. TH-A-BRC-02: AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Goetsch, S. [San Diego Medical Physics (United States)

    2016-06-15

    AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline

  7. TH-A-BRC-02: AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance

    International Nuclear Information System (INIS)

    Goetsch, S.

    2016-01-01

    AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline

  8. ASSOCIATION BETWEEN COMPUTED TOMOGRAPHIC CHARACTERISTICS AND FRACTURES FOLLOWING STEREOTACTIC RADIOSURGERY IN DOGS WITH APPENDICULAR OSTEOSARCOMA.

    Science.gov (United States)

    Kubicek, Lyndsay; Vanderhart, Daniel; Wirth, Kimberly; An, Qi; Chang, Myron; Farese, James; Bova, Francis; Sudhyadhom, Atchar; Kow, Kelvin; Bacon, Nicholas J; Milner, Rowan

    2016-05-01

    The objective of this observational, descriptive, retrospective study was to report CT characteristics associated with fractures following stereotactic radiosurgery in canine patients with appendicular osteosarcoma. Medical records (1999 and 2012) of dogs that had a diagnosis of appendicular osteosarcoma and undergone stereotactic radiosurgery were reviewed. Dogs were included in the study if they had undergone stereotactic radiosurgery for an aggressive bone lesion with follow-up information regarding fracture status, toxicity, and date and cause of death. Computed tomography details, staging, chemotherapy, toxicity, fracture status and survival data were recorded. Overall median survival time (MST) and fracture rates of treated dogs were calculated. CT characteristics were evaluated for association with time to fracture. Forty-six dogs met inclusion criteria. The median overall survival time was 9.7 months (95% CI: 6.9-14.3 months). The fracture-free rates at 3, 6, and 9 months were 73%, 44%, and 38% (95% CI: 60-86%, 29-60%, and 22-54%), respectively. The region of bone affected was significantly associated with time to fracture. The median time to fracture was 4.2 months in dogs with subchondral bone involvement and 16.3 months in dogs without subchondral bone involvement (P-value = 0.027, log-rank test). Acute and late skin effects were present in 58% and 16% of patients, respectively. Findings demonstrated a need for improved patient selection for this procedure, which can be aided by CT-based prognostic factors to predict the likelihood of fracture. © 2016 American College of Veterinary Radiology.

  9. Stereotactic radiosurgery vs. fractionated radiotherapy for tumor control in vestibular schwannoma patients

    DEFF Research Database (Denmark)

    Persson, Oscar; Bartek, Jiri; Shalom, Netanel Ben

    2017-01-01

    OBJECTIVE: Repeated controlled studies have revealed that stereotactic radiosurgery is better than microsurgery for patients with vestibular schwannoma (VS) ... to patients treated with fractionated stereotactic radiotherapy. RESULTS: No randomized controlled trial (RCT) was identified. None of the identified controlled studies comparing SRS with FSRT were eligible according to the inclusion criteria. Nineteen case series on SRS (n = 17) and FSRT (n = 2) were...... included in the systematic review. Loss of tumor control necessitating a new VS-targeted intervention was found in an average of 5.0% of the patients treated with SRS and in 4.8% treated with FSRT. Mean deterioration ratio for patients with serviceable hearing before treatment was 49% for SRS and 45...

  10. Adverse radiation effect after stereotactic radiosurgery for brain metastases : incidence, time course, and risk factors

    NARCIS (Netherlands)

    Sneed, Penny K.; Mendez, Joe; Vemer-van den Hoek, Johanna; Seymour, Zachary A.; Ma, Lijun; Molinaro, Annette M.; Fogh, Shannon E.; Nakamura, Jean L.; McDermott, Michael W.

    OBJECT The authors sought to determine the incidence, time course, and risk factors for overall adverse radiation effect (ARE) and symptomatic ARE after stereotactic radiosurgery (SRS) for brain metastases. METHODS All cases of brain metastases treated from 1998 through 2009 with Gamma Knife SRS at

  11. Repeat Stereotactic Radiosurgery for Acoustic Neuromas

    International Nuclear Information System (INIS)

    Kano, Hideyuki; Kondziolka, Douglas; Niranjan, Ajay M.Ch.; Flannery, Thomas J.; Flickinger, John C.; Lunsford, L. Dade

    2010-01-01

    Purpose: To evaluate the outcome of repeat stereotactic radiosurgery (SRS) for acoustic neuromas, we assessed tumor control, clinical outcomes, and the risk of adverse radiation effects in patients whose tumors progressed after initial management. Methods and Materials: During a 21-year experience at our center, 1,352 patients underwent SRS as management for their acoustic neuromas. We retrospectively identified 6 patients who underwent SRS twice for the same tumor. The median patient age was 47 years (range, 35-71 years). All patients had imaging evidence of tumor progression despite initial SRS. One patient also had incomplete surgical resection after initial SRS. All patients were deaf at the time of the second SRS. The median radiosurgery target volume at the time of the initial SRS was 0.5 cc and was 2.1 cc at the time of the second SRS. The median margin dose at the time of the initial SRS was 13 Gy and was 11 Gy at the time of the second SRS. The median interval between initial SRS and repeat SRS was 63 months (range, 25-169 months). Results: At a median follow-up of 29 months after the second SRS (range, 13-71 months), tumor control or regression was achieved in all 6 patients. No patient developed symptomatic adverse radiation effects or new neurological symptoms after the second SRS. Conclusions: With this limited experience, we found that repeat SRS for a persistently enlarging acoustic neuroma can be performed safely and effectively.

  12. Neurosymptomatic carvenous sinus meningioma: a 15-years experience with fractionated stereotactic radiotherapy and radiosurgery

    International Nuclear Information System (INIS)

    Correa, Sebastião Francisco Miranda; Marta, Gustavo Nader; Teixeira, Manoel Jacobsen

    2014-01-01

    The tumor removal of Cavernous Sinus Meningiomas usually results in severe neurological deficits. Stereotactic radiosurgery (SRS) and fractionated Stereotactic radiotherapy (SRT) are advanced modalities of radiotherapy for treatment of patients with inoperable and symptomatic CSMs. The authors evaluated the long term symptomatology, the image findings, and the toxicity of patients with CSMs treated with SRS or SRT. From 1994 to 2009, 89 patients with symptomatic CSMs were treated with SRS or SRT. The indication was based on tumour volume and or proximity to the optic chiasm. The median single dose of SRS was 14 Gy, while the SRT total dose, ranged from 50.4 to 54 Gy fractionated in 1.8-2 Gy/dose. The median follow-up period lasted 73 months. The clinical and radiological improvement was the same despite the method of radiotherapy; 41.6% (SRS) and 48.3% (SRT) of patients treated. The disease-free survivals were 98.8%, 92.3% and 92.3%, in 5, 10, and 15 years, respectively. There was no statistical difference in relation to the symptoms and image findings between both methods. According to the Common Toxicity Criteria, 7% of the patients presented transient optic neuropathy during 3 months (grade 2) and recovered with dexamethasone, 2 patients had trigeminal neuropathy (grade 2) and improved rapidly, and one patient presented total occlusion of the internal carotid artery without neurological deficit (grade 2). Temporary lethargy and headache (grade 1) were the most frequent immediate complications. No severe complications occurred. Stereotactic Radiosurgery and fractionated Stereotactic Radiotherapy were equally safe and effective in the management of symptomatic CSMs

  13. Universal behavior of charged particle production in heavy ion collisions

    Science.gov (United States)

    Phobos Collaboration; Steinberg, Peter A.; Back, B. B.; Baker, M. D.; Barton, D. S.; Betts, R. R.; Ballintijn, M.; Bickley, A. A.; Bindel, R.; Budzanowski, A.; Busza, W.; Carroll, A.; Decowski, M. P.; Garcia, E.; George, N.; Gulbrandsen, K.; Gushue, S.; Halliwell, C.; Hamblen, J.; Heintzelman, G. A.; Henderson, C.; Hofman, D. J.; Hollis, R. S.; Hołński, R.; Holzman, B.; Iordanova, A.; Johnson, E.; Kane, J. L.; Katzy, J.; Khan, N.; Kucewicz, W.; Kulinich, P.; Kuo, C. M.; Lin, W. T.; Manly, S.; McLeod, D.; Michałowski, J.; Mignerey, A. C.; Nouicer, R.; Olszewski, A.; Pak, R.; Park, I. C.; Pernegger, H.; Reed, C.; Remsberg, L. P.; Reuter, M.; Roland, C.; Roland, G.; Rosenberg, L.; Sagerer, J.; Sarin, P.; Sawicki, P.; Skulski, W.; Steadman, S. G.; Steinberg, P.; Stephans, G. S. F.; Stodulski, M.; Sukhanov, A.; Tang, J.-L.; Teng, R.; Trzupek, A.; Vale, C.; van Nieuwenhuizen, G. J.; Verdier, R.; Wadsworth, B.; Wolfs, F. L. H.; Wosiek, B.; Woźniak, K.; Wuosmaa, A. H.; Wysłouch, B.

    2003-03-01

    The PHOBOS experiment at RHIC has measured the multiplicity of primary charged particles as a function of centrality and pseudorapidity in Au+Au collisions at sqrt(s_NN) = 19.6, 130 and 200 GeV. Two kinds of universal behavior are observed in charged particle production in heavy ion collisions. The first is that forward particle production, over a range of energies, follows a universal limiting curve with a non-trivial centrality dependence. The second arises from comparisons with pp/pbar-p and e+e- data. N_tot/(N_part/2) in nuclear collisions at high energy scales with sqrt(s) in a similar way as N_tot in e+e- collisions and has a very weak centrality dependence. This feature may be related to a reduction in the leading particle effect due to the multiple collisions suffered per participant in heavy ion collisions.

  14. Treatment of cancer with heavy charged particles

    International Nuclear Information System (INIS)

    Castro, J.R.

    1981-01-01

    The clinical radiotherapy trial has accured 243 patients irradiated with particles and 13 patients irradiated as controls in randomized studies. Of the 243 particle patients, 194 have been treated with helium ions, either solely or in combination with photon irradiation, and 49 have received all or part of their irradiation with one of the heavier particles, either carbon, neon, or argon ions. The project thus can be divided into two general phases: (1) evaluation of improved dose distribution without significant biologic advantage by use of helium ion irradiation; and (2) evaluation of improved dose distribution and enhanced biologic effect by irradiation with heavy charged particles such as carbon, neon, and argon ions

  15. Particle therapy for noncancer diseases

    Energy Technology Data Exchange (ETDEWEB)

    Bert, Christoph; Engenhart-Cabillic, Rita; Durante, Marco [GSI Helmholtzzentrum fuer Schwerionenforschung, Biophysics Department, Planckstrasse 1, 64291 Darmstadt (Germany); Philipps-University Marburg, Center for Radiology, Department of Radiation Therapy, Baldinger Strasse, 35043 Marburg (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung, Biophysics Department, Planckstrasse 1, 64291 Darmstadt (Germany); Technische Universitaet Darmstadt, Institut fuer Festkoerperphysik, Hochschulstrasse 3, 64289 Darmstadt (Germany) and Frankfurt Institute for Advanced Studies, Johann Wolfgang Goethe University, Ruth-Moufang-Str. 1, 60438 Frankfurt am Main (Germany)

    2012-04-15

    Radiation therapy using high-energy charged particles is generally acknowledged as a powerful new technique in cancer treatment. However, particle therapy in oncology is still controversial, specifically because it is unclear whether the putative clinical advantages justify the high additional costs. However, particle therapy can find important applications in the management of noncancer diseases, especially in radiosurgery. Extension to other diseases and targets (both cranial and extracranial) may widen the applications of the technique and decrease the cost/benefit ratio of the accelerator facilities. Future challenges in this field include the use of different particles and energies, motion management in particle body radiotherapy and extension to new targets currently treated by catheter ablation (atrial fibrillation and renal denervation) or stereotactic radiation therapy (trigeminal neuralgia, epilepsy, and macular degeneration). Particle body radiosurgery could be a future key application of accelerator-based particle therapy facilities in 10 years from today.

  16. Cell inactivation by heavy charged particles

    Energy Technology Data Exchange (ETDEWEB)

    Blakely, E A [Lawrence Berkeley Lab., CA (United States). Cell and Molecular Biology Div.

    1992-06-01

    The inactivation of cells resulting in lethal or aberrant effects by charged particles is of growing interest. Charged particles at extremely high LET are capable of completely eliminating cell-type and cell-line differences in repair capacity. It is still not clear however whether the repair systems are inactivated, or merely that heavy-ion lesions are less repairable. Studies correlating the particle inactivation dose of radioresistant cells with intact DNA analyzed with pulse field gel electrophoresis and other techniques may be useful, but more experiments are also needed to assess the fidelity of repair. For particle irradiations between 40-100 keV/{mu}m there is however evidence for particle-induced activation of specific genes in mammalian cells, and certain repair processes in bacteria. New data are available on the inactivation of developmental processes in several systems including seeds, and cells of the nematode C. elegans. Future experimental and theoretical modeling research emphasis should focus on exploring particle-induced inactivation of endpoints assessing functionality and not just lethality, and on analyzing molecular damage and genetic effects arising in damage but non-inactivated survivors. The discrete nature of selective types of particle damage as a function of radiation quality indicates the value of accelerated ions as probes of normal and aberrant biological processes. Information obtained from molecular analyses of damage and repair must however be integrated into the context of cellular and tissue functions of the organism. (orig.).

  17. Constituent quarks and charge particle production in heavy-ion collisions

    International Nuclear Information System (INIS)

    Mishra, Aditya Nath; Mazumder, Rakesh; Sahoo, Raghunath; Nandi, Basanta Kumar

    2012-01-01

    Relativistic heavy-ion collisions aims at producing a state of matter which is governed by partonic degree of freedom. The pseudorapidity density of particle multiplicity and transverse energy are the key observables which provide the properties of matter produced in heavy-ion collisions. Study of their dependence on centrality and collision energy is of paramount importance to understand the particle production mechanism. This may provide insight into the partonic phase that might be created in nuclear collisions. Here, in a constituent quarks framework, charged particle and transverse energy production in heavy-ion collisions are studied both as a function of centrality and collision energy, and hence the study gives a prediction for Pb + Pb collisions

  18. Results of stereotactic radiosurgery for patients with imaging defined cavernous sinus meningiomas

    International Nuclear Information System (INIS)

    Pollock, Bruce E.; Stafford, Scott L.

    2005-01-01

    Introduction: The purpose of this study was to evaluate the efficacy and safety of stereotactic radiosurgery as primary management for patients with imaging defined cavernous sinus meningiomas. Methods: Between 1992 and 2001, 49 patients had radiosurgery for dural-based masses of the cavernous sinus presumed to be meningiomas. The mean patient age was 55.5 years. The mean tumor volume was 10.2 mL; the mean tumor margin dose was 15.9 Gy. The mean follow-up was 58 months (range, 16-144 months). Results: No tumor enlarged after radiosurgery. Twelve of 38 patients (26%) with preexisting diplopia or facial numbness/pain had improvement in cranial nerve function. Five patients (10%) had new (n = 3) or worsened (n = 2) trigeminal dysfunction; 2 of these patients (4%) underwent surgery at 20 and 25 months after radiosurgery despite no evidence of tumor progression. Neither patient improved after partial tumor resection. One patient (2%) developed an oculomotor nerve injury. One patient (2%) had an ischemic stroke related to occlusion of the cavernous segment of the internal carotid artery. Event-free survival was 98%, 85%, and 80% at 1, 3, and 7 years after radiosurgery, respectively. Univariate analysis of patient and dosimetric factors found no analyzed factor correlated with postradiosurgical morbidity. Conclusions: Radiosurgery was an effective primary management strategy for patients with an imaging defined cavernous sinus meningioma. Except in situations of symptomatic mass effect, unusual clinical presentation, or atypical imaging features, surgery to confirm the histologic diagnosis is unlikely to provide clinical benefit

  19. Clinical Evaluation of Stereotactic Target Localization Using 3-Tesla MRI for Radiosurgery Planning

    International Nuclear Information System (INIS)

    MacFadden, Derek; Zhang Beibei; Brock, Kristy K.; Hodaie, Mojgan; Laperriere, Normand; Schwartz, Michael; Tsao, May; Stainsby, Jeffrey; Lockwood, Gina; Mikulis, David; Menard, Cynthia

    2010-01-01

    Purpose: Increasing the magnetic resonance imaging (MRI) field strength can improve image resolution and quality, but concerns remain regarding the influence on geometric fidelity. The objectives of the present study were to spatially investigate the effect of 3-Tesla (3T) MRI on clinical target localization for stereotactic radiosurgery. Methods and Materials: A total of 39 patients were enrolled in a research ethics board-approved prospective clinical trial. Imaging (1.5T and 3T MRI and computed tomography) was performed after stereotactic frame placement. Stereotactic target localization at 1.5T vs. 3T was retrospectively analyzed in a representative cohort of patients with tumor (n = 4) and functional (n = 5) radiosurgical targets. The spatial congruency of the tumor gross target volumes was determined by the mean discrepancy between the average gross target volume surfaces at 1.5T and 3T. Reproducibility was assessed by the displacement from an averaged surface and volume congruency. Spatial congruency and the reproducibility of functional radiosurgical targets was determined by comparing the mean and standard deviation of the isocenter coordinates. Results: Overall, the mean absolute discrepancy across all patients was 0.67 mm (95% confidence interval, 0.51-0.83), significantly .4), and the gross target volume surface mean displacements were similar within and between users. The overall average isocenter coordinate discrepancy for the functional targets at 1.5T and 3T was 0.33 mm (95% confidence interval, 0.20-0.48), with no patient-specific differences between the mean values (p >.2) or standard deviations (p >.1). Conclusion: Our results have provided clinically relevant evidence supporting the spatial validity of 3T MRI for use in stereotactic radiosurgery under the imaging conditions used.

  20. Stereotactic radiosurgery versus whole-brain radiotherapy after intracranial metastasis resection : A systematic review and meta-analysis

    NARCIS (Netherlands)

    Lamba, Nayan; Muskens, Ivo S; DiRisio, Aislyn C; Meijer, Louise; Briceno, Vanessa; Edrees, Heba; Aslam, Bilal; Minhas, Sadia; Verhoeff, Joost J.C.; Kleynen, Catharina E.; Smith, Timothy R; Mekary, Rania A; Broekman, Marike L.

    2017-01-01

    Background: In patients with one to three brain metastases who undergo resection, options for post-operative treatments include whole-brain radiotherapy (WBRT) or stereotactic radiosurgery (SRS) of the resection cavity. In this meta-analysis, we sought to compare the efficacy of each post-operative

  1. Light charged particle emission in heavy-ion reactions – What have ...

    Indian Academy of Sciences (India)

    coincidence with gamma rays, fission products, evaporation residues have yielded interesting results which bring out the influence of nuclear structure, nuclear mean field and dynamics on the emission of these particles. Keywords. Light charged particles; heavy-ion induced reactions; particle spectra and angular distri-.

  2. Technical and anatomical aspects of novalis stereotactic radiosurgery sphenopalatine ganglionectomy

    International Nuclear Information System (INIS)

    De Salles, Antonio A.F.; Gorgulho, Alessandra; Golish, S. Raymond Ph.D.; Medin, Paul M.; Malkasian, Dennis; Solberg, Timothy D.; Selch, Michael T.

    2006-01-01

    Background: Several techniques have been applied for destruction of the sphenopalatine ganglion to control cluster headache and ocular pain with sympathetic component. Cluster headache has responded to radiofrequency ablation or phenol destruction. Radiosurgery of the sphenopalatine ganglion is promising due to the excellent visualization of the target on magnetic resonance imaging (MRI), computed tomography (CT), and skull X-rays. Material and Methods: Six patients and one cadaver head were analyzed in this study. The cadaver-head dissection confirmed the location of the sphenopalatine ganglion on X-rays and CT imaging. One patient undergoing radiofrequency sphenopalatine ablation participated for confirmation of the location of the ganglion on plain X-rays. Five patients received radiosurgery of the sphenopalatine ganglion. One patient had classic unilateral cluster headache. Two patients had neuropathic pain and 1 had bilateral migrainous neuralgia. The fifth patient had bilateral atypical facial pain. All received a single maximal dose of 90 Gy with a 5- or 7.5-mm circular collimator. MRI, CT, and skull X-rays identified and confirmed the target. Results: The sphenopalatine fossa is seen in the skull X-ray as an inverse tear drop just caudal to the sphenoid sinus. This location is readily correlated to the CT target by the stereotactic coordinates and confirmed with the presence of the ganglion visualized in the MRI scan. Only the patient with cluster headache experienced lasting pain relief. Conclusion: Multiple imaging modalities confirmed the location of the sphenopalatine ganglion for radiosurgery. The procedure was performed safely with CT and MRI fusion. Radiosurgery was significantly beneficial only on classic cluster headache

  3. Charged Particle, Photon Multiplicity, and Transverse Energy Production in High-Energy Heavy-Ion Collisions

    Directory of Open Access Journals (Sweden)

    Raghunath Sahoo

    2015-01-01

    Full Text Available We review the charged particle and photon multiplicities and transverse energy production in heavy-ion collisions starting from few GeV to TeV energies. The experimental results of pseudorapidity distribution of charged particles and photons at different collision energies and centralities are discussed. We also discuss the hypothesis of limiting fragmentation and expansion dynamics using the Landau hydrodynamics and the underlying physics. Meanwhile, we present the estimation of initial energy density multiplied with formation time as a function of different collision energies and centralities. In the end, the transverse energy per charged particle in connection with the chemical freeze-out criteria is discussed. We invoke various models and phenomenological arguments to interpret and characterize the fireball created in heavy-ion collisions. This review overall provides a scope to understand the heavy-ion collision data and a possible formation of a deconfined phase of partons via the global observables like charged particles, photons, and the transverse energy measurement.

  4. Improvement of radiological penumbra using intermediate energy photons (IEP) for stereotactic radiosurgery

    International Nuclear Information System (INIS)

    O'Malley, Lauren; Pignol, Jean-Philippe; Beachey, David J; Keller, Brian M; Presutti, Joseph; Sharpe, Michael

    2006-01-01

    Using efficient immobilization and dedicated beam collimation devices, stereotactic radiosurgery ensures highly conformal treatment of small tumours with limited microscopic extension. One contribution to normal tissue irradiation remains the radiological penumbra. This work aims at demonstrating that intermediate energy photons (IEP), above orthovoltage but below megavoltage, improve dose distribution for stereotactic radiosurgery for small irradiation field sizes due to a dramatic reduction of radiological penumbra. Two different simulation systems were used: (i) Monte Carlo simulation to investigate the dose distribution of monoenergetic IEP between 100 keV and 1 MeV in water phantom; (ii) the Pinnacle 3 TPS including a virtual IEP unit to investigate the dosimetry benefit of treating with 11 non-coplanar beams a 2 cm tumour in the middle of a brain adjacent to a 1 mm critical structure. Radiological penumbrae below 300 μm are generated for field size below 2 x 2 cm 2 using monoenergetic IEP beams between 200 and 400 keV. An 800 kV beam generated in a 0.5 mm tungsten target maximizes the photon intensity in this range. Pinnacle 3 confirms the dramatic reduction in penumbra size. DVHs show for a constant dose distribution conformality, improved dose distribution homogeneity and better sparing of critical structures using a 800 kV beam compared to a 6 MV beam

  5. Improvement of radiological penumbra using intermediate energy photons (IEP) for stereotactic radiosurgery

    Science.gov (United States)

    O'Malley, Lauren; Pignol, Jean-Philippe; Beachey, David J.; Keller, Brian M.; Presutti, Joseph; Sharpe, Michael

    2006-05-01

    Using efficient immobilization and dedicated beam collimation devices, stereotactic radiosurgery ensures highly conformal treatment of small tumours with limited microscopic extension. One contribution to normal tissue irradiation remains the radiological penumbra. This work aims at demonstrating that intermediate energy photons (IEP), above orthovoltage but below megavoltage, improve dose distribution for stereotactic radiosurgery for small irradiation field sizes due to a dramatic reduction of radiological penumbra. Two different simulation systems were used: (i) Monte Carlo simulation to investigate the dose distribution of monoenergetic IEP between 100 keV and 1 MeV in water phantom; (ii) the Pinnacle3 TPS including a virtual IEP unit to investigate the dosimetry benefit of treating with 11 non-coplanar beams a 2 cm tumour in the middle of a brain adjacent to a 1 mm critical structure. Radiological penumbrae below 300 µm are generated for field size below 2 × 2 cm2 using monoenergetic IEP beams between 200 and 400 keV. An 800 kV beam generated in a 0.5 mm tungsten target maximizes the photon intensity in this range. Pinnacle3 confirms the dramatic reduction in penumbra size. DVHs show for a constant dose distribution conformality, improved dose distribution homogeneity and better sparing of critical structures using a 800 kV beam compared to a 6 MV beam.

  6. Stereotactic Radiosurgery and Fractionated Stereotactic Radiation Therapy for the Treatment of Uveal Melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Yazici, Gozde [Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Kiratli, Hayyam [Department of Ophthalmology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Ozyigit, Gokhan; Sari, Sezin Yuce; Cengiz, Mustafa [Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Tarlan, Bercin [Bascom Palmer Eye Institute, Miami, Florida (United States); Mocan, Burce Ozgen [Department of Radiology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Zorlu, Faruk, E-mail: fzorlu@hacettepe.edu.tr [Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara (Turkey)

    2017-05-01

    Purpose: To evaluate treatment results of stereotactic radiosurgery or fractionated stereotactic radiation therapy (SRS/FSRT) for uveal melanoma. Methods and Materials: We retrospectively evaluated 181 patients with 182 uveal melanomas receiving SRS/FSRT between 2007 and 2013. Treatment was administered with CyberKnife. Results: According to Collaborative Ocular Melanoma Study criteria, tumor size was small in 1%, medium in 49.5%, and large in 49.5% of the patients. Seventy-one tumors received <45 Gy, and 111 received ≥45 Gy. Median follow-up time was 24 months. Complete and partial response was observed in 8 and 104 eyes, respectively. The rate of 5-year overall survival was 98%, disease-free survival 57%, local recurrence-free survival 73%, distant metastasis-free survival 69%, and enucleation-free survival 73%. There was a significant correlation between tumor size and disease-free survival, SRS/FSRT dose and enucleation-free survival; and both were prognostic for local recurrence-free survival. Enucleation was performed in 41 eyes owing to progression in 26 and complications in 11. Conclusions: The radiation therapy dose is of great importance for local control and eye retention; the best treatment outcome was achieved using ≥45 Gy in 3 fractions.

  7. Stereotactic Radiosurgery and Fractionated Stereotactic Radiation Therapy for the Treatment of Uveal Melanoma

    International Nuclear Information System (INIS)

    Yazici, Gozde; Kiratli, Hayyam; Ozyigit, Gokhan; Sari, Sezin Yuce; Cengiz, Mustafa; Tarlan, Bercin; Mocan, Burce Ozgen; Zorlu, Faruk

    2017-01-01

    Purpose: To evaluate treatment results of stereotactic radiosurgery or fractionated stereotactic radiation therapy (SRS/FSRT) for uveal melanoma. Methods and Materials: We retrospectively evaluated 181 patients with 182 uveal melanomas receiving SRS/FSRT between 2007 and 2013. Treatment was administered with CyberKnife. Results: According to Collaborative Ocular Melanoma Study criteria, tumor size was small in 1%, medium in 49.5%, and large in 49.5% of the patients. Seventy-one tumors received <45 Gy, and 111 received ≥45 Gy. Median follow-up time was 24 months. Complete and partial response was observed in 8 and 104 eyes, respectively. The rate of 5-year overall survival was 98%, disease-free survival 57%, local recurrence-free survival 73%, distant metastasis-free survival 69%, and enucleation-free survival 73%. There was a significant correlation between tumor size and disease-free survival, SRS/FSRT dose and enucleation-free survival; and both were prognostic for local recurrence-free survival. Enucleation was performed in 41 eyes owing to progression in 26 and complications in 11. Conclusions: The radiation therapy dose is of great importance for local control and eye retention; the best treatment outcome was achieved using ≥45 Gy in 3 fractions.

  8. International Spine Radiosurgery Consortium Consensus Guidelines for Target Volume Definition in Spinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Cox, Brett W.; Spratt, Daniel E.; Lovelock, Michael; Bilsky, Mark H.; Lis, Eric; Ryu, Samuel; Sheehan, Jason; Gerszten, Peter C.; Chang, Eric; Gibbs, Iris; Soltys, Scott; Sahgal, Arjun; Deasy, Joe; Flickinger, John; Quader, Mubina; Mindea, Stefan

    2012-01-01

    Purpose: Spinal stereotactic radiosurgery (SRS) is increasingly used to manage spinal metastases. However, target volume definition varies considerably and no consensus target volume guidelines exist. This study proposes consensus target volume definitions using common scenarios in metastatic spine radiosurgery. Methods and Materials: Seven radiation oncologists and 3 neurological surgeons with spinal radiosurgery expertise independently contoured target and critical normal structures for 10 cases representing common scenarios in metastatic spine radiosurgery. Each set of volumes was imported into the Computational Environment for Radiotherapy Research. Quantitative analysis was performed using an expectation maximization algorithm for Simultaneous Truth and Performance Level Estimation (STAPLE) with kappa statistics calculating agreement between physicians. Optimized confidence level consensus contours were identified using histogram agreement analysis and characterized to create target volume definition guidelines. Results: Mean STAPLE agreement sensitivity and specificity was 0.76 (range, 0.67-0.84) and 0.97 (range, 0.94-0.99), respectively, for gross tumor volume (GTV) and 0.79 (range, 0.66-0.91) and 0.96 (range, 0.92-0.98), respectively, for clinical target volume (CTV). Mean kappa agreement was 0.65 (range, 0.54-0.79) for GTV and 0.64 (range, 0.54-0.82) for CTV (P<.01 for GTV and CTV in all cases). STAPLE histogram agreement analysis identified optimal consensus contours (80% confidence limit). Consensus recommendations include that the CTV should include abnormal marrow signal suspicious for microscopic invasion and an adjacent normal bony expansion to account for subclinical tumor spread in the marrow space. No epidural CTV expansion is recommended without epidural disease, and circumferential CTVs encircling the cord should be used only when the vertebral body, bilateral pedicles/lamina, and spinous process are all involved or there is extensive metastatic

  9. A Review of Stereotactic Radiosurgery Practice in the Management of Skull Base Meningiomas

    OpenAIRE

    Vera, Elena; Iorgulescu, J. Bryan; Raper, Daniel M.S.; Madhavan, Karthik; Lally, Brian E.; Morcos, Jacques; Elhammady, Samy; Sherman, Jonathan; Komotar, Ricardo J.

    2014-01-01

    Gross total resection of skull base meningiomas poses a surgical challenge due to their proximity to neurovascular structures. Once the gold standard therapy for skull base meningiomas, microsurgery has been gradually replaced by or used in combination with stereotactic radiosurgery (SRS). This review surveys the safety and efficacy of SRS in the treatment of cranial base meningiomas including 36 articles from 1991 to 2010. SRS produces excellent tumor control with low morbidity rates compare...

  10. Nelson's syndrome: single centre experience using the linear accelerator (LINAC) for stereotactic radiosurgery and fractionated stereotactic radiotherapy.

    Science.gov (United States)

    Wilson, Peter J; Williams, Janet R; Smee, Robert I

    2014-09-01

    Nelson's syndrome is a unique clinical phenomenon of growth of a pituitary adenoma following bilateral adrenalectomies for the control of Cushing's disease. Primary management is surgical, with limited effective medical therapies available. We report our own institution's series of this pathology managed with radiation: prior to 1990, 12 patients were managed with conventional radiotherapy, and between 1990 and 2007, five patients underwent stereotactic radiosurgery (SRS) and two patients fractionated stereotactic radiotherapy (FSRT), both using the linear accelerator (LINAC). Tumour control was equivocal, with two of the five SRS patients having a reduction in tumour volume, one patient remaining unchanged, and two patients having an increase in volume. In the FSRT group, one patient had a decrease in tumour volume whilst the other had an increase in volume. Treatment related morbidity was low. Nelson's syndrome is a challenging clinical scenario, with a highly variable response to radiation in our series. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. The current status of radiosurgery

    International Nuclear Information System (INIS)

    Mehta, Minesh P.

    1996-01-01

    Objectives: Review the role of radiosurgery in recurrent malignant gliomas for palliative purposes. Review the role of radiosurgery in newly diagnosed malignant glioma as boost therapy and emphasize the randomized clinical trials underway. Review the role of radiosurgery in the management of patients with brain metastases and emphasize the major prognostic factors. Review the recently initiated clinical trials for brain metastases using radiosurgery. Review the role of radiosurgery in the management of benign tumors with specific emphasis on meningioma and acoustic neuroma. Emphasize the rationale for fractionation and present the preliminary results of fractionated stereotactic radiation. Stereotactic localization techniques, originally designed for neurosurgery, have been used to delivery high single doses of radiation to small intracranial targets for more than 25 years, a technique referred to as stereotactic radiosurgery. Radiosurgery has proven to be an attractive alternative to surgery in the management of several benign tumors, such as vestibular schwannomas with better preservation of hearing and facial nerve function than microsurgical resection. For other benign tumors such as meningioma and pituitary adenoma, preliminary results are promising, but longer range studies to confirm high tumor control rates are necessary. For patients with malignant glioma, radiosurgery has been used to escalate the radiation dose to enhance tumor control following surgery and radiation therapy. The rationale for this is grounded in the recent confirmatory randomized prospective trial verifying the value of brachytherapy in this disease. The results of radiosurgery from single institutional experiences for primary and recurrent malignant glioma indicate a palliative benefit as well as a potential survival benefit in a select sub-group of patients based on the appropriate mix of prognostic criteria such as patient age, performance status, tumor size and extent of resection

  12. Coulomb ionization of inner shells by heavy charged particles

    International Nuclear Information System (INIS)

    Lapicki, G.

    1975-01-01

    The theory of inner-shell Coulomb ionization by heavy charged particles, of atomic number small compared to the target atomic number, is developed through the extension of work by Brandt and his coworkers for K shells to L shells. In slow collisions relative to the characteristic times of the inner shell electrons, the quantum-mechanical predictions in the plane-wave Born approximation (PWBA) can exceed experimental cross sections by orders of magnitude. The effects of the perturbation of the atom by and the Coulomb deflection of the particle during collisions are included in the theory. The perturbed atomic states amount to a binding of the inner-shell electrons to the moving particle in slow collisions, and to a polarization of the inner shells by the particle passing at large impact parameters during nonadiabatic collisions. These effects, not contained in the PWBA, are treated in the framework of the perturbed stationary state (PSS) theory for slow collisions and in terms of the harmonic oscillator model of Ashley, Brandt, and Ritchie for stopping powers in fast collisions. The effect of the Coulomb deflection of the particle in the field of the target nucleus on the cross sections is incorporated in the semiclassical approximation of Bang and Hansteen. Except for the lightest target atoms, the contribution of electron capture by the particles to inner-shell ionizations is shown to be negligible. The theory as developed earlier for the K shell, and here for L shells, agrees well with the vast body of experimental data on inner-shell Coulomb ionization by heavy charged particles

  13. A quality assurance program in stereotactic radiosurgery using the gamma knife unit

    International Nuclear Information System (INIS)

    Stuecklschweiger, G.F.; Feichtinger, K.

    1998-01-01

    Because of the large single fraction dose in stereotactic radiosurgery it is important to guarantee a high geometric and dosimetric accuracy. The paper represent the quality assurance program for the Gamma Knife unit at the University Clinic of Neurosurgery in Graz. The program includes the following procedures: Timer control, mechanical radiation isocenter coincidence, trunnion centricity, helmet microswitches test, radiation output and relative helmet factors, dose profile verification, safety interlocks checks and software quality assurance. In summary, the mechanical accuracy and reproducibility of the Gamma Knife unit are [de

  14. Cushing's disease: a single centre's experience using the linear accelerator (LINAC) for stereotactic radiosurgery and fractionated stereotactic radiotherapy.

    Science.gov (United States)

    Wilson, P J; Williams, J R; Smee, R I

    2014-01-01

    Cushing's disease is hypercortisolaemia secondary to an adrenocorticotrophic hormone secreting pituitary adenoma. Primary management is almost always surgical, with limited effective medical interventions available. Adjuvant therapy in the form of radiation is gaining popularity, with the bulk of the literature related to the Gamma Knife. We present the results from our own institution using the linear accelerator (LINAC) since 1990. Thirty-six patients who underwent stereotactic radiosurgery (SRS), one patient who underwent fractionated stereotactic radiotherapy (FSRT) and for the purposes of comparison, 13 patients who had undergone conventional radiotherapy prior to 1990, were included in the analysis. Serum cortisol levels improved in nine of 36 (25%) SRS patients and 24 hour urinary free cortisol levels improved in 13 of 36 patients (36.1%). Tumour volume control was excellent in the SRS group with deterioration in only one patient (3%). The patient who underwent FSRT had a highly aggressive tumour refractory to radiation. Published by Elsevier Ltd.

  15. Dose delivery verification and accuracy assessment of stereotaxy in stereotactic radiotherapy and radiosurgery

    International Nuclear Information System (INIS)

    Pelagade, S.M.; Bopche, T.T.; Namitha, K.; Munshi, M.; Bhola, S.; Sharma, H.; Patel, B.K.; Vyas, R.K.

    2008-01-01

    The outcome of stereotactic radiotherapy (SRT) and stereotactic radiosurgery (SRS) in both benign and malignant tumors within the cranial region highly depends on precision in dosimetry, dose delivery and the accuracy assessment of stereotaxy associated with the unit. The frames BRW (Brown-Roberts-Wells) and GTC (Gill- Thomas-Cosman) can facilitate accurate patient positioning as well as precise targeting of tumours. The implementation of this technique may result in a significant benefit as compared to conventional therapy. As the target localization accuracy is improved, the demand for treatment planning accuracy of a TPS is also increased. The accuracy of stereotactic X Knife treatment planning system has two components to verify: (i) the dose delivery verification and the accuracy assessment of stereotaxy; (ii) to ensure that the Cartesian coordinate system associated is well established within the TPS for accurate determination of a target position. Both dose delivery verification and target positional accuracy affect dose delivery accuracy to a defined target. Hence there is a need to verify these two components in quality assurance protocol. The main intention of this paper is to present our dose delivery verification procedure using cylindrical wax phantom and accuracy assessment (target position) of stereotaxy using Geometric Phantom on Elekta's Precise linear accelerator for stereotactic installation

  16. Stereotactic Radiosurgery in the Management of Brain Metastases: An Institutional Retrospective Analysis of Survival

    International Nuclear Information System (INIS)

    Frazier, James L.; Batra, Sachin; Kapor, Sumit; Vellimana, Ananth; Gandhi, Rahul; Carson, Kathryn A.; Shokek, Ori; Lim, Michael; Kleinberg, Lawrence; Rigamonti, Daniele

    2010-01-01

    Purpose: The objective of this study was to report our experience with stereotactic radiosurgery performed with the Gamma Knife (GK) in the treatment of patients with brain metastases and to compare survival for those treated with radiosurgery alone with survival for those treated with radiosurgery and whole-brain radiotherapy. Methods and Materials: Prospectively collected demographic and clinical characteristics and treatment and survival data on 237 patients with intracranial metastases who underwent radiosurgery with the GK between 2003 and 2007 were reviewed. Kaplan-Meier and Cox proportional hazards regression analyses were used to compare survival by demographic and clinical characteristics and treatment. Results: The mean age of the patient population was 56 years. The most common tumor histologies were non-small-cell lung carcinoma (34.2%) and breast cancer (13.9%). The median overall survival time was 8.5 months from the time of treatment. The median survival times for patients with one, two/three, and four or more brain metastases were 8.5, 9.4, and 6.7 months, respectively. Patients aged 65 years or greater and those aged less than 65 years had median survival times of 7.8 and 9 months, respectively (p = 0.008). The Karnofsky Performance Score (KPS) at the time of treatment was a significant predictor of survival: those patients with a KPS of 70 or less had a median survival of 2.9 months compared with 10.3 months (p = 0.034) for those with a KPS of 80 or greater. There was no statistically significant difference in survival between patients treated with radiosurgery alone and those treated with radiosurgery plus whole-brain radiotherapy. Conclusions: Radiosurgery with the GK is an efficacious treatment modality for brain metastases. A KPS greater than 70, histology of breast cancer, smaller tumor volume, and age less than 65 years were associated with a longer median survival in our study.

  17. Alignment verification in stereotactic radiosurgery with use of graphic arts film

    International Nuclear Information System (INIS)

    Sweet, J.; Lamba, M.

    1990-01-01

    This paper evaluates the use of graphic arts film for field alignment verification of linear accelerator-based stereotactic radiosurgery. The characteristic curve was generated for Fuji RO-100 graphic arts film in a standard leaded radiation therapy cassette at 6 MV. The linear portion of the curve and the film contrast are presented and their clinical advantages discussed. The high contrast of this graphic arts film improves visualization of the 5-mm ball bearing (simulated target) in small, circular treatment fields. Comparison with standard port film demonstrates the large linear range of the graphic arts film, which proved useful in visualization of the simulated target within the small, circular treatment field

  18. Gold nanoparticle enhancement of stereotactic radiosurgery for neovascular age-related macular degeneration

    Science.gov (United States)

    Ngwa, Wilfred; Makrigiorgos, G. Mike; Berbeco, Ross I.

    2012-10-01

    Age-related macular degeneration (AMD) is the leading cause of blindness in developed countries for people over the age of 50. In this work, the dosimetric feasibility of using gold nanoparticles (AuNP) as radiosensitizers to enhance kilovoltage stereotactic radiosurgery for neovascular AMD is investigated. Microdosimetry calculations at the sub-cellular level were carried out to estimate the radiation dose enhancement to individual nuclei in neovascular AMD endothelial cells (nDEF) due to photon-induced photo-/Auger electrons from x-ray-irradiated AuNP. The nDEF represents the ratio of radiation doses to the endothelial cell nuclei with and without AuNP. The calculations were carried out for a range of feasible AuNP local concentrations using the clinically applicable 100 kVp x-ray beam parameters employed by a commercially available x-ray therapy system. The results revealed nDEF values of 1.30-3.26 for the investigated concentration range of 1-7 mg g-1, respectively. In comparison, for the same concentration range, nDEF values of 1.32-3.40, 1.31-3.33, 1.29-3.19, 1.28-3.12 were calculated for 80, 90, 110 and 120 kVp x-rays, respectively. Meanwhile, calculations as a function of distance from the AuNP showed that the dose enhancement, for 100 kVp, is markedly confined to the targeted neovascular AMD endothelial cells where AuNP are localized. These findings provide impetus for considering the application of AuNP to enhance therapeutic efficacy during stereotactic radiosurgery for neovascular AMD.

  19. Dose calculations algorithm for narrow heavy charged-particle beams

    Energy Technology Data Exchange (ETDEWEB)

    Barna, E A; Kappas, C [Department of Medical Physics, School of Medicine, University of Patras (Greece); Scarlat, F [National Institute for Laser and Plasma Physics, Bucharest (Romania)

    1999-12-31

    The dose distributional advantages of the heavy charged-particles can be fully exploited by using very efficient and accurate dose calculation algorithms, which can generate optimal three-dimensional scanning patterns. An inverse therapy planning algorithm for dynamically scanned, narrow heavy charged-particle beams is presented in this paper. The irradiation `start point` is defined at the distal end of the target volume, right-down, in a beam`s eye view. The peak-dose of the first elementary beam is set to be equal to the prescribed dose in the target volume, and is defined as the reference dose. The weighting factor of any Bragg-peak is determined by the residual dose at the point of irradiation, calculated as the difference between the reference dose and the cumulative dose delivered at that point of irradiation by all the previous Bragg-peaks. The final pattern consists of the weighted Bragg-peaks irradiation density. Dose distributions were computed using two different scanning steps equal to 0.5 mm, and 1 mm respectively. Very accurate and precise localized dose distributions, conform to the target volume, were obtained. (authors) 6 refs., 3 figs.

  20. Universal behavior of charged particle production in heavy ion collisions at RHIC energies

    Science.gov (United States)

    Steinberg, Peter A.; Back, B. B.; Baker, M. D.; Barton, D. S.; Betts, R. R.; Ballintijn, M.; Bickley, A. A.; Bindel, R.; Budzanowski, A.; Busza, W.; Carroll, A.; Decowski, M. P.; García, E.; George, N.; Gulbrandsen, K.; Gushue, S.; Halliwell, C.; Hamblen, J.; Heintzelman, G. A.; Henderson, C.; Hofman, D. J.; Hollis, R. S.; Holyński, R.; Holzman, B.; Iordanova, A.; Johnson, E.; Kane, J. L.; Katzy, J.; Khan, N.; Kucewicz, W.; Kulinich, P.; Kuo, C. M.; Lin, W. T.; Manly, S.; McLeod, D.; Michałowski, J.; Mignerey, A. C.; Nouicer, R.; Olszewski, A.; Pak, R.; Park, I. C.; Pernegger, H.; Reed, C.; Remsberg, L. P.; Reuter, M.; Roland, C.; Roland, G.; Rosenberg, L.; Sagerer, J.; Sarin, P.; Sawicki, P.; Skulski, W.; Steadman, S. G.; Steinberg, P.; Stephans, G. S. F.; Stodulski, M.; Sukhanov, A.; Tang, J.-L.; Teng, R.; Trzupek, A.; Vale, C.; van Nieuwenhuizen, G. J.; Verdier, R.; Wadsworth, B.; Wolfs, F. L. H.; Wosiek, B.; Woźniak, K.; Wuosmaa, A. H.; Wysłouch, B.; Phobos Collaboration

    2003-04-01

    The PHOBOS experiment at RHIC has measured the multiplicity of primary charged particles as a function of centrality and pseudorapidity in Au+Au collisions at √ SNN = 19.6, 130 and 200 GeV. Two kinds of universal behavior are observed in charged particle production in heavy ion collisions. The first is that forward particle production, over a range of energies, follows a universal limiting curve with a non-trivial centrality dependence. The second arises from comparisons with pp/ overlinepp and e +e - data. / in nuclear collisions at high energy scales with √ s in a similar way as Nch in e +e - collisions and has a very weak centrality dependence. This feature may be related to a reduction in the leading particle effect due to the multiple collisions suffered per participant in heavy ion collisions.

  1. Optimization of dose distribution for the system of linear accelerator-based stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Suh Taesuk.

    1990-01-01

    This work addresses a method for obtaining an optimal dose distribution of stereotactic radiosurgery. Since stereotactic radiosurgery utilizes multiple noncoplanar arcs and a three-dimensional dose evaluation technique, many beam parameters and complex optimization criteria are included in the dose optimization. Consequently, a lengthy computation time is required to optimize even the simplest case by a trial and error method. The basic approach presented here is to use both an analytical and an experimental optimization to minimize the dose to critical organs while maintaining a dose shaped to the target. The experimental approach is based on shaping the target volumes using multiple isocenters from dose experience, or on field shaping using a beam's eye view technique. The analytical approach is to adapt computer-aided design optimization to find optimum parameters automatically. Three-dimensional approximate dose models are developed to simulate the exact dose model using a spherical or cylindrical coordinate system. Optimum parameters are found much faster with the use of computer-aided design optimization techniques. The implementation of computer-aided design algorithms with the approximate dose model and the application of the algorithms to several cases are discussed. It is shown that the approximate dose model gives dose distributions similar to those of the exact dose model, which makes the approximate dose model an attractive alternative to the exact dose model, and much more efficient in terms of computer-aided design and visual optimization

  2. Image-Guided Stereotactic Radiosurgery Using a Specially Designed High-Dose-Rate Linac

    International Nuclear Information System (INIS)

    Bayouth, John E.; Kaiser, Heather S.; Smith, Mark C.; Pennington, Edward C.; Anderson, Kathleen M. C.; Ryken, Timothy C.; Buatti, John M.

    2007-01-01

    Stereotactic radiosurgery and image-guided radiotherapy (IGRT) place enhanced demands on treatment delivery machines. In this study, we describe a high-dose-rate output accelerator as a part of our stereotactic IGRT delivery system. The linac is a Siemens Oncor without a flattening filter, and enables dose rates to reach 1000 monitor units (MUs) per minute. Even at this high-dose-rate, the linac dosimetry system remains robust; constancy, linearity, and beam energy remain within 1% for 3 to 1000 MU. Dose profiles for larger field sizes are not flat, but they are radially symmetric and, as such, able to be modeled by a treatment planning system. Target localization is performed via optical guidance utilizing a 3-dimensional (3D) ultrasound probe coupled to an array of 4 infrared light-emitting diodes. These diodes are identified by a fixed infrared camera system that determines diode position and, by extension, all objects imaged in the room coordinate system. This system provides sub-millimeter localization accuracy for cranial applications and better than 1.5 mm for extracranial applications. Because stereotactic IGRT can require significantly longer times for treatment delivery, the advantages of the high-dose-rate design and its direct impact on IGRT are discussed

  3. Fractionated stereotactically guided radiotherapy and radiosurgery in the treatment of functional and nonfunctional adenomas of the pituitary gland

    International Nuclear Information System (INIS)

    Milker-Zabel, Stefanie; Debus, Juergen; Thilmann, Christoph; Schlegel, Wolfgang; Wannenmacher, Michael

    2001-01-01

    Purpose: We evaluated survival rates and side effects after fractionated stereotactically guided radiotherapy (SCRT) and radiosurgery in patients with pituitary adenoma. Methods and Materials: Between 1989 and 1998, 68 patients were treated with FSRT (n=63) or radiosurgery (n=5) for pituitary adenomas. Twenty-six had functional and 42 had nonfunctional adenomas. Follow-up included CT/MRI, endocrinologic, and ophthalmologic examinations. Mean follow-up was 38.7 months. Seven patients received radiotherapy as primary treatment and 39 patients received it postoperatively for residual disease. Twenty-two patients were treated for recurrent disease after surgery. Mean total dose was 52.2 Gy for SCRT, and 15 Gy for radiosurgery. Results: Overall local tumor control was 93% (60/65 patients). Forty-three patients had stable disease based on CT/MRI, while 15 had a reduction of tumor volume. After FSRT, 26% with a functional adenoma had a complete remission and 19% had a reduction of hormonal overproduction after 34 months' mean. Two patients with STH-secreting adenomas had an endocrinologic recurrence, one with an ACTH-secreting adenoma radiologic recurrence, within 54 months. Reduction of visual acuity was seen in 4 patients and partial hypopituitarism in 3 patients. None of the patients developed brain radionecrosis or radiation-induced gliomas. Conclusion: Stereotactically guided radiotherapy is effective and safe in the treatment of pituitary adenomas to improve local control and reduce hormonal overproduction

  4. Intractable trigeminal neuralgia: A single institution experience in 26 patients treated with stereotactic gamma knife radiosurgery

    International Nuclear Information System (INIS)

    Mark, Rufus J.; Duma, Christopher M.; Jacques, Dean B.; Kopyov, Oleg V.; Copcutt, Brian

    1996-01-01

    Purpose: In patients with trigeminal neuralgia, severe pain can persist, or recur despite aggressive medical management and open surgery. Recently, Gamma Knife radiosurgery has been used with promising results. We report on our series of 26 patients with intractable trigeminal neuralgia treated with stereotactic Gamma Knife radiosurgery. Materials and Methods: Between 1991 and 1995, 26 patients with intractable trigeminal neuralgia were treated at our institution using stereotactic Gamma Knife radiosurgery. Medical management had failed in all cases. In addition, 13 patients underwent a total of 20 open surgeries, with transient, or no pain relief. There were 19 females, and 7 males. Patient ages ranged from 37 to 87 years, with a median of 74 years. All patients were treated with a 201 source Cobalt-60 Gamma Knife unit. All patients underwent placement of the Leksell frame, followed by MRI scanning and computer treatment planning. The target in all patients was the fifth cranial nerve root entry zone into the brainstem. Twenty-five patients received between 64.3 to 70 Gy prescribed to Dmax in one shot. One patient received 120 Gy to Dmax in one shot. The 4 mm collimator was used in 22 cases, and the 8 mm in 4 cases. Follow-up ranged from 5 to 55 months, with a median of 19 months. Complete resolution (CR) of pain was scored when the patient reported being pain free off all medication. Partial resolution (PR) was scored when the patient reported > 50% pain reduction after Gamma Knife treatment. Results: At last follow-up, 84.6% ((22(26))) reported CR or PR of pain after Gamma Knife treatment. Forty-two percent ((11(26))) of patients reported CR, and 42%((11(26))) reported PR of pain. There was a dose response. In patients receiving < 70 Gy, 25% ((3(12))) reported CR, while 57% ((8(14))) of those receiving ≥ 70 Gy reported CR. Complications occurred in two (8%) patients. One patient developed transient numbness of the face after 70 Gy, and a second patient

  5. Stereotactic radiosurgery for brainstem metastases: Survival, tumor control, and patient outcomes

    International Nuclear Information System (INIS)

    Hussain, Aamir; Brown, Paul D.; Stafford, Scott L.; Pollock, Bruce E.

    2007-01-01

    Purpose: Patients with brainstem metastases have limited treatment options. In this study, we reviewed outcomes after stereotactic radiosurgery (SRS) in the management of patients with brainstem metastases. Methods and Materials: Records were reviewed of 22 consecutive patients presenting with brainstem metastases who underwent SRS. The most frequent primary malignancy was the lung (n = 11), followed by breast (n = 3) and kidney (n = 2). Three patients (14%) also underwent whole-brain radiation therapy (WBRT). The median tumor volume was 0.9 mL (range, 0.1-3.3 mL); the median tumor margin dose was 16 Gy (range, 14-23 Gy). Results: Median survival time after SRS was 8.5 months. Although local tumor control was achieved in all patients with imaging follow-up (n = 19), 5 patients died from development and progression of new brain metastases. Two patients (9%) had symptom improvement after SRS, whereas 1 patient (5%) developed a new hemiparesis after SRS. Conclusions: Radiosurgery is safe and provides a high local tumor control rate for patients with small brainstem metastases. Patients with limited systemic disease and good performance status should be strongly considered for SRS

  6. Cataract production in mice by heavy charged particles

    International Nuclear Information System (INIS)

    Ainsworth, E.H.; Jose, J.; Yang, V.V.; Barker, M.E.

    1981-03-01

    The cataractogenic effects of heavy charged particles have been evaluated in mice in relation to dose and ionization density (LET/sub infinity/). The study was undertaken due to the high potential for eye exposures to HZE particles among SPS personnel working in outer space. This has made it imperative that the relative biological effectiveness (RBE) in relation to LET/sub infinity/ for various particles be defined so that appropriate quality factors (Q) could be assigned for estimation of risk. Although mice and men differ in susceptibility to radiation-induced cataracts, the results from this project should assist in defining appropriate quality factors in relation to LET/sub infinity/, particle mass, charge, or velocity. Evaluation of results indicated that : (1) low single doses (5 to 20 rad) of iron ( 56 Fe) or argon ( 40 Ar) particles are cataractogenic at 11 to 18 months after irradiation; (2) onset and density of the opacification are dose related; (3) cataract density (grade) at 9, 11, 13, and 16 months after irradiation shows partial LET/sub infinity/-dependence; and (4) the severity of cataracts is reduced significantly when 417 rad of 60 Co gamma radiation is given in 24 weekly 17 rad fractions compared to giving this radiation as a single dose, but cataract severity is not reduced by fractionation of 12 C doses over 24 weeks

  7. Linac radiosurgery for high-grade gliomas: the University of Florida experience

    Energy Technology Data Exchange (ETDEWEB)

    Buatti, John M; Friedman, William A; Bova, Frank J; Mendenhall, William M

    1995-04-30

    Purpose: Stereotactic radiosurgery has been reported as a promising boost technique for the treatment of selected patients with high-grade glioma. The first 11 patients given this treatment at the University of Florida are reported. Methods and Materials: Six patients with glioblastoma multiforme and five with anaplastic astrocytoma were carefully selected for treatment with linac radiosurgery. All patients had a Karnofsky performance status {>=} 90%. Median age of patients was 42.1 years. External-beam radiotherapy delivered a median dose of 60 Gy. Stereotactic radiosurgery was delivered to the enhancing tumor volume without margin. Median treatment volume was 14 cm{sup 3} (equivalent sphere diameter, 3 cm). The maximum volume of any tumor treated was 22.5 cm{sup 3} (equivalent sphere diameter, 3.5 cm). Median stereotactic radiosurgery boost dose was 12.5 Gy, and median prescription sphere was the 80% isodose shell. Results: Despite rigorous selection and aggressive stereotactic boost irradiation, this patient cohort had a median actuarial survival of 17 months. All patients have had progression of intracranial disease within 1 year of radiosurgery, and only 3 of 11 remain alive with a median follow-up of 13 months. Conclusion: These results differ significantly from others reported. Comparative analysis suggests tumor volume may be an important prognostic factor in patients treated with stereotactic radiosurgery. Future studies need to define appropriate patient cohorts for the boost technique.

  8. Geometrical and dosimetrical characterization of the photon source using a micro-multileaf collimator for stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Treuer, H; Hoevels, M; Luyken, K; Hunsche, S; Kocher, M; Mueller, R-P; Sturm, V

    2003-01-01

    A micro-multileaf collimator (μMLC) for stereotactic radiosurgery is used for determination of the spatial intensity distribution of the photon source of a linear accelerator. The method is based on grid field dose measurements using film dosimetry and is easy to perform. Since the μMLC does not allow 'direct' imaging of the photon source, special software has been developed to analyse grid field measurements. Besides the source-density function, grid field analysis yields the position of the focal spot in the room laser coordinate system of the linear accelerator and the position of the treatment head rotation axis and the inclination angle of the leaf bank. Thus the method can be used for base dosimetry and for quality assurance in radiosurgery using a μMLC

  9. Silent Corticotroph Adenomas After Stereotactic Radiosurgery: A Case–Control Study

    International Nuclear Information System (INIS)

    Xu, Zhiyuan; Ellis, Scott; Lee, Cheng-Chia; Starke, Robert M.; Schlesinger, David; Lee Vance, Mary; Lopes, M. Beatriz; Sheehan, Jason

    2014-01-01

    Purpose: To investigate the safety and effectiveness of stereotactic radiosurgery (SRS) in patients with a silent corticotroph adenoma (SCA) compared with patients with other subtypes of non–adrenocorticotropic hormone staining nonfunctioning pituitary adenoma (NFA). Methods and Materials: The clinical features and outcomes of 104 NFA patients treated with SRS in our center between September 1994 and August 2012 were evaluated. Among them, 34 consecutive patients with a confirmatory SCA were identified. A control group of 70 patients with other subtypes of NFA were selected for review based on comparable baseline features, including sex, age at the time of SRS, tumor size, margin radiation dose to the tumor, and duration of follow-up. Results: The median follow-up after SRS was 56 months (range, 6-200 months). No patients with an SCA developed Cushing disease during the follow-up. Tumor control was achieved in 21 of 34 patients (62%) in the SCA group, compared with 65 of 70 patients (93%) in the NFA group. The median progression-free survival (PFS) was 58 months in the SCA group. The actuarial PFS was 73%, 46%, and 31% in the SCA group and was 94%, 87%, and 87% in the NFA group at 3, 5, and 8 years, respectively. Silent corticotroph adenomas treated with a dose of ≥17 Gy exhibited improved PFS. New-onset loss of pituitary function developed in 10 patients (29%) in the SCA group, whereas it occurred in 18 patients (26%) in the NFA group. Eight patients (24%) in the SCA group experienced worsening of a visual field deficit or visual acuity attributed to the tumor progression, as did 6 patients (9%) in the NFA group. Conclusion: Silent corticotroph adenomas exhibited a more aggressive course with a higher progression rate than other subtypes of NFAs. Stereotactic radiosurgery is an important adjuvant treatment for control of tumor growth. Increased radiation dose may lead to improved tumor control in SCA patients

  10. Silent Corticotroph Adenomas After Stereotactic Radiosurgery: A Case–Control Study

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhiyuan; Ellis, Scott; Lee, Cheng-Chia; Starke, Robert M. [Department of Neurological Surgery, University of Virginia, Charlottesville, Virginia (United States); Schlesinger, David [Department of Neurological Surgery, University of Virginia, Charlottesville, Virginia (United States); Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia (United States); Lee Vance, Mary [Department of Neurological Surgery, University of Virginia, Charlottesville, Virginia (United States); Department of Internal Medicine, University of Virginia, Charlottesville, Virginia (United States); Lopes, M. Beatriz [Division of Neuropathology, University of Virginia, Charlottesville, Virginia (United States); Sheehan, Jason, E-mail: jsheehan@virginia.edu [Department of Neurological Surgery, University of Virginia, Charlottesville, Virginia (United States); Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia (United States)

    2014-11-15

    Purpose: To investigate the safety and effectiveness of stereotactic radiosurgery (SRS) in patients with a silent corticotroph adenoma (SCA) compared with patients with other subtypes of non–adrenocorticotropic hormone staining nonfunctioning pituitary adenoma (NFA). Methods and Materials: The clinical features and outcomes of 104 NFA patients treated with SRS in our center between September 1994 and August 2012 were evaluated. Among them, 34 consecutive patients with a confirmatory SCA were identified. A control group of 70 patients with other subtypes of NFA were selected for review based on comparable baseline features, including sex, age at the time of SRS, tumor size, margin radiation dose to the tumor, and duration of follow-up. Results: The median follow-up after SRS was 56 months (range, 6-200 months). No patients with an SCA developed Cushing disease during the follow-up. Tumor control was achieved in 21 of 34 patients (62%) in the SCA group, compared with 65 of 70 patients (93%) in the NFA group. The median progression-free survival (PFS) was 58 months in the SCA group. The actuarial PFS was 73%, 46%, and 31% in the SCA group and was 94%, 87%, and 87% in the NFA group at 3, 5, and 8 years, respectively. Silent corticotroph adenomas treated with a dose of ≥17 Gy exhibited improved PFS. New-onset loss of pituitary function developed in 10 patients (29%) in the SCA group, whereas it occurred in 18 patients (26%) in the NFA group. Eight patients (24%) in the SCA group experienced worsening of a visual field deficit or visual acuity attributed to the tumor progression, as did 6 patients (9%) in the NFA group. Conclusion: Silent corticotroph adenomas exhibited a more aggressive course with a higher progression rate than other subtypes of NFAs. Stereotactic radiosurgery is an important adjuvant treatment for control of tumor growth. Increased radiation dose may lead to improved tumor control in SCA patients.

  11. Search for long-lived heavy charged particles using a ring imaging Cherenkov technique at LHCb

    NARCIS (Netherlands)

    Aaij, R.; Adeva, B.; Adinolfi, M.; Affolder, A.; Ajaltouni, Z.; Akar, S.; Albrecht, J.; Alessio, F.; Alexander, M.; Ali, S.; Alkhazov, G.; Cartelle, P. Alvarez; Alves, A. A., Jr.; Amato, S.; Amerio, S.; Amhis, Y.; Everse, LA; Anderlini, L.; Anderson, J.; Andreotti, M.; Andrews, J.E.; Appleby, R. B.; Gutierrez, O. Aquines; Archilli, F.; d'Argent, P.; Artamonov, A.; Artuso, M.; Aslanides, E.; Auriemma, G.; Baalouch, M.; Bachmann, S.; Back, J. J.; Badalov, A.; Baesso, C.; Baldini, W.; Barlow, R. J.; Barschel, C.; Barsuk, S.; Barter, W.; Batozskaya, V.; Battista, V.; Bay, A.; Beaucourt, L.; Beddow, J.; Bedeschi, F.; Bediaga, I.; Bel, L. J.; Belyaev, I.; Ben-Haim, E.; Bencivenni, G.; Benson, S.; Benton, J.; Berezhnoy, A.; Bernet, R.; Bertolin, A.; Bettler, M-O.; Van Beuzekom, Martin; Bien, A.; Bifani, S.; Bird, T.D.; Birnkraut, A.; Bizzeti, A.; Blake, T.; Blanc, F.; Blouw, J.; Blusk, S.; Bocci, V.; Bondar, A.; Bondar, N.; Bonivento, W.; Borghi, S.; Borgia, A.; Borsato, M.; Bowcock, T. J. V.; Bowen, E.; Bozzi, C.; Brett, D.; Britsch, M.; Britton, T.; Brodzicka, J.; Brook, N. H.; Bursche, A.; Buytaert, J.; Cadeddu, S.; Calabrese, R.; Calvi, M.; Calvo Gomez, M.; Campana, P.; Perez, D. H. Campora; Capriotti, L.; Carbone, A.; Carboni, G.; Cardinale, R.; Cardini, A.; Carniti, P.; Carson, L.; Carvalho Akiba, K.; Casanova Mohr, R.; Casse, G.; Cassina, L.; Garcia, L. Castillo; Cattaneo, M.; Cauet, Ch; Cavallero, G.; Cenci, R.; Charles, M.; Charpentier, Ph; Chefdeville, M.; Chen, S.; Cheung, S-F.; Chiapolini, N.; Chrzaszcz, M.; Vidal, X. Cid; Ciezarek, G.; Clarke, P. E. L.; Clemencic, M.; Cliff, H. V.; Closier, J.; Coco, V.; Cogan, J.; Cogneras, E.; Cogoni, V.; Cojocariu, L.; Collazuol, G.; Collins, P.; Comerma-Montells, A.; Contu, A.; Cook, A.; Coombes, M.; Coquereau, S.; Corti, G.; Corvo, M.; Counts, I.; Couturier, B.; Cowan, G. A.; Craik, D. C.; Crocombe, A.; CruzTorres, M.; Cunliffe, S.; Currie, C.R.; D'Ambrosio, C.; Dalseno, J.; David, P. N. Y.; Davis, A.; De Bruyn, K.; De Capua, S.; De Cian, M.; de Miranda, J. M.; Paula, L.E.; da-Silva, W.S.; De Simone, P.; Dean, C-T.; Decamp, D.; Deckenhoff, M.; Del Buono, L.; Deleage, N.; Derkach, D.; Deschamps, O.; Dettori, F.; Dey, B.; Di Canto, A.; Di Ruscio, F.; Dijkstra, H.; Donleavy, S.; Dordei, F.; Dorigo, M.; Dosil Suarez, A.; Dossett, D.; Dovbnya, A.; Dreimanis, K.; Dujany, G.; Dupertuis, F.; Durante, P.; Dzhelyadin, R.; Dziurda, A.; Dzyuba, A.; Easo, S.; Egede, U.; Egorychev, V.; Eidelman, S.; Eisenhardt, S.; Eitschberger, U.; Ekelhof, R.; Eklund, L.; ElRifai, I.; Elsasser, Ch.; Ely, S.; Esen, S.; Evans, H. M.; Evans, T. M.; Falabella, A.; Faerber, C.; Farinelli, C.; Farley, N.; Farry, S.; Fay, R.; Ferguson, D.; Fernandez Albor, V.; Ferrari, F.; Ferreira Rodrigues, F.; Ferro-Luzzi, M.; Filippov, S.; Fiore, M.; Fiorini, M.; Firlej, M.; Fitzpatrick, C.; Fiutowski, T.; Fol, P.; Fontana, Mark; Fontanelli, F.; Forty, R.; De Aguiar Francisco, O.; Frank, M.; Frei, C.; Frosini, M.; Fu, J.; Furfaro, E.; Torreira, A. Gallas; Galli, D.; Gallorini, S.; Gambetta, S.; Gandelman, M.; Gandini, P.; Gao, Y.; Garcia Pardinas, J.; Garofoli, J.; Tico, J. Garra; Garrido, L.; Gascon, D.; Carvalho-Gaspar, M.; Gauld, Rhorry; Gavardi, L.; Gazzoni, G.; Geraci, A.; Gerick, D.; Gersabeck, E.; Gersabeck, M.; Gershon, T. J.; Ghez, Ph; Gianelle, A.; Giani, S.; Gibson, V.; Giubega, L.; Gligorov, V. V.; Goebel, C.; Golubkov, D.; Golutvin, A.; Gomes, A.Q.; Gotti, C.; Gandara, M. Grabalosa; Diaz, R. Graciani; Cardoso, L. A. Granado; Grauges, E.; Graverini, E.; Graziani, G.; Grecu, A.; Greening, E.; Gregson, S.; Griffith, P.; Grillo, L.; Gruenberg, O.; Gui, B.; Gushchin, E.; Guz, Yu; Gys, T.; Hadjivasiliou, C.; Haefeli, G.; Haen, C.; Haines, S. C.; Hall, S.; Hamilton, B.; Hampson, T.; Han, X.; Hansmann-Menzemer, S.; Harnew, N.; Harnew, S. T.; Harrison, J.; He, J.; Head, T.; Heijne, V.; Hennessy, K.; Henrard, P.; Henry, L.; Hernando Morata, J. A.; van Herwijnen, E.; Hess, H.M.; Hicheur, A.; Hill, D.; Hoballah, M.; Hombach, C.; Hulsbergen, W.; Humair, T.; Hussain, N.; Hutchcroft, D. E.; Hynds, D.; Idzik, M.; Ilten, P.; Jacobsson, R.; Jaeger, A.; Jalocha, J.; Jans, E.; Jawahery, A.; Jing, F.; John, M.; Johnson, D.; Jones, C. R.; Joram, C.; Jost, B.; Jurik, N.; Kandybei, S.; Kanso, W.; Karacson, M.; Karbach, T. M.; Karodia, S.; Kelsey, M. H.; Kenyon, I. R.; Kenzie, M.; Ketel, T.; Khanji, B.; Khurewathanakul, C.; Klaver, S.M.; Klimaszewski, K.; Kochebina, O.; Kolpin, M.; Komarov, I.; Koopman, R. F.; Koppenburg, P.; Kravchuk, L.; Kreplin, K.; Kreps, M.; Krocker, G.; Krokovny, P.; Kruse, F.; Kucewicz, W.; Kucharczyk, M.; Kudryavtsev, V.; Kurek, K.; Kvaratskheliya, T.; La Thi, V. N.; Lacarrere, D.; Lafferty, G. D.; Lai, A.; Lambert, D.M.; Lambert, R. W.; Lanfranchi, G.; Langenbruch, C.; Langhans, B.; Latham, T. E.; Lazzeroni, C.; Le Gac, R.; van Leerdam, J.; Lees, J. P.; Lefevre, R.; Leflat, A.; Lefrancois, J.; Leroy, O.; Lesiak, T.; Leverington, B.; Li, Y.; Likhomanenko, T.; Liles, M.; Lindner, R.; Linn, S.C.; Lionetto, F.; Liu, B.; Lohn, S.; Longstaff, I.; Lopes, J. H.; Lucchesi, D.; Luo, H.; Lupato, A.; Luppi, E.; Lupton, O.; Machefert, F.; Machikhiliyan, I. V.; Maciuc, F.; Maev, O.; Malde, S.; Malinin, A.; Manca, G.; Mancinelli, G.; Manning, P.; Mapelli, A.; Maratas, J.; Marchand, J. F.; Marconi, U.; Marin Benito, C.; Marino, P.; Maerki, R.; Marks, J.; Martellotti, G.; Martinelli-Boneschi, F.; Santos, D. Martinez; Martinez-Vidal, F.; Martins Tostes, D.; Massafferri, A.; Matev, R.; Mathe, Z.; Matteuzzi, C.; Mauri, A.; Maurin, B.; Mazurov, A.; McCann, M.; McCarthy, J.; Mcnab, A.; McNulty, R.; McSkelly, B.; Meadows, B. T.; Meier, F.; Meissner, M.; Merk, M.; Milanes, D. A.; Minard, M. N.; Mitzel, D. S.; Molina Rodriguez, J.; Monteil, S.; Morandin, M.; Morawski, P.; Morda, A.; Morello, M. J.; Moron, J.; Morris, A. B.; Mountain, R.; Muheim, F.; Mueller, J.; Mueller, Karl; Mueller, V.; Mussini, M.; Muster, B.; Naik, P.; Nakada, T.; Nandakumar, R.; Nasteva, I.; Needham, M.; Neri, N.; Neubert, S.; Neufeld, N.; Neuner, M.; Nguyen, A. D.; Nguyen, T. D.; Nguyen-Mau, C.; Niess, V.; Niet, R.; Nikitin, N.; Nikodem, T.; Novoselov, A.; O'Hanlon, D. P.; Oblakowska-Mucha, A.; Obraztsov, V.; Ogilvy, S.; Okhrimenko, O.; Oldeman, R.; Onderwater, C. J. G.; Osorio Rodrigues, B.; Otalora Goicochea, J. M.; Otto, E.A.; Owen, R.P.; Oyanguren, A.; Palano, A.; Palombo, F.; Palutan, M.; Panman, J.; Papanestis, A.; Pappagallo, M.; Pappalardo, L.L.; Parkes, C.; Passaleva, G.; Patel, G. D.; Patel, M.; Patrignani, C.; Pearce, D.A.; Pellegrino, A.; Penso, G.; Altarelli, M. Pepe; Perazzini, S.; Perret, P.; Pescatore, L.; Petridis, K.; Petrolini, A.; Olloqui, E. Picatoste; Pietrzyk, B.; Pilar, T.; Pinci, D.; Pistone, A.; Playfer, S.; Plo Casasus, M.; Poikela, T.; Polci, F.; Poluektov, A.; Polyakov, I.; Polycarpo, E.; Popov, A.; Popov, D.; Popovici, B.; Potterat, C.; Price, M. E.; Price, J.D.; Prisciandaro, J.; Pritchard, C.A.; Prouve, C.; Pugatch, V.; Navarro, A. Puig; Punzi, G.; Qian, Y.W.; Quagliani, R.; Rachwal, B.; Rademacker, J. H.; Rakotomiaramanana, B.; Rama, M.; Rangel, M. S.; Raniuk, I.; Rauschmayr, N.; Raven, G.; Redi, F.; Reichert, S.; Reid, M.; dos Reis, A. C.; Ricciardi, S.; Richards, Jennifer S; Rihl, M.; Rinnert, K.; Rives Molina, V.; Robbe, P.; Rodrigues, A. B.; Rodrigues, L.E.T.; Perez, P. Rodriguez; Roiser, S.; Romanovsky, V.; Romero Vidal, A.; Rotondo, M.; Rouvinet, J.; Ruf, T.; Ruiz, van Hapere; Ruiz Valls, P.; Saborido Silva, J. J.; Sagidova, N.; Sail, P.; Saitta, B.; Salustino Guimaraes, V.; Sanchez Mayordomo, C.; Sanmartin Sedes, B.; Santacesaria, R.; Santamarina Rios, C.; Santovetti, E.; Sarti, A.; Satriano, C.; Satta, A.; Saunders, D. M.; Savrina, D.; Schiller, M.; Schindler, R. H.; Schlupp, M.; Schmelling, M.; Schmelzer, T.; Schmidt, B.; Schneider, O.; Schopper, A.; Schune, M. H.; Schwemmer, R.; Sciascia, B.; Sciubba, A.; Semennikov, A.; Sepp, I.; Serra, N.; Serrano, J.; Sestini, L.; Seyfert, P.; Shapkin, M.; Shapoval, I.; Shcheglov, Y.; Shears, T.; Shekhtman, L.; Shevchenko, V.; Shires, A.; Coutinho, R. Silva; Simi, G.; Sirendi, M.; Skidmore, N.; Skillicorn, I.; Skwarnicki, T.; Smith, E.; Smith, E.; Smith, J; Smith, M.; Snoek, H.; Sokoloff, M. D.; Soler, F. J. P.; Soomro, F.; de Souza, D.K.; Souza De Paula, B.; Spaan, B.; Spradlin, P.; Sridharan, S.; Stagni, F.; Stahl, M.; Stahl, S.; Steinkamp, O.; Stenyakin, O.; Sterpka, F.; Stevenson-Moore, P.; Stoica, S.; Stone, S.; Storaci, B.; Stracka, S.; Straticiuc, M.; Straumann, U.; Stroili, R.; Sun, L.; Sutcliffe, W.; Swientek, K.; Swientek, S.; Syropoulos, V.; Szczekowski, M.; Szczypka, P.; Szumlak, T.; T'Jampens, S.; Tekampe, T.; Teklishyn, M.; Tellarini, G.; Teubert, F.; Thomas, C.; Thomas, E.; van Tilburg, J.; Tisserand, V.; Tobin, M. N.; Todd, Jim; Tolk, S.; Tomassetti, L.; Tonelli, D.; Topp-Joergensen, S.; Torr, N.; Tournefier, E.; Tourneur, S.; Trabelsi, K.; Tran, N.T.M.T.; Tresch, M.; Trisovic, A.; Tsaregorodtsev, A.; Tsopelas, P.; Tuning, N.; Garcia, M. Ubeda; Ukleja, A.; Ustyuzhanin, A.; Uwer, U.; Vacca, C.; Vagnoni, V.; Valenti, G.; Vallier, A.; Gomez, R. Vazquez; Vazquez Regueiro, P.; Vazquez Sierra, C.; Vecchi, S.; Velthuis, M.J.; Veltri, M.; Veneziano, G.; Vesterinen, M.; Viaud, B.; Vieira, D.; Vieites Diaz, M.; Vilasis-Cardona, X.; Vollhardt, A.; Volyanskyy, D.; Voong, D.; Vorobyev, A.; Vorobyev, V.; Voss, C.; de Vries, J. A.; Waldi, R.; Wallace, C.; Wallace, R.; Walsh, John; Wandernoth, S.; Wang, J.; Ward, D. R.; Watson, N. K.; Websdale, D.; Weiden, A.; Whitehead, M.; Wiedner, D.; Wilkinson, G.; Wilkinson, M.; Williams, M.; Williams, M.P.; Williams, M.; Wilson, James F; Wimberley, J.; Wishahi, J.; Wislicki, W.; Witek, M.; Wormser, G.; Wotton, S. A.; Wright, S.J.; Wyllie, K.; Xie, Y.; Xu, Z.; Yang, Z.; Yuan, X.; Yushchenko, O.; Zangoli, M.; Zavertyaev, M.; Zhang, L.; Zhang, Y.; Zhelezov, A.; Zhokhov, A.; Zhong, L.

    2015-01-01

    A search is performed for heavy long-lived charged particles using 3.0 fb(-1) of proton-proton collisions collected at √s = 7 and 8 TeV with the LHCb detector. The search is mainly based on the response of the ring imaging Cherenkov detectors to distinguish the heavy, slow-moving particles from

  12. Physical fundamentals of the application of heavy charged particles in radiotherapy

    International Nuclear Information System (INIS)

    Bueche, G.

    1977-01-01

    In the chapter 'Medical Applications' A 'Radiotherapy' of the study, the following subjects are treated in detail by various authors: Physical fundamentals of the application of heavy charged particles in radiotherapy-radiation-biological fundamentals; clinical aspects of radiotherapy with protons and negative pions; patients and clinical dosimetry. (MG) [de

  13. Stereotactic radiosurgery for the treatment of meningiomas; Radiocirurgia estereotaxica no tratamento de meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Penna, Antonio Belmiro Rodrigues Campbell [Hospital dos Servidores do Estado, Rio de Janeiro, RJ (Brazil). Servico de Radioterapia; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Vieira, Sergio Lannes [Hospital Sao Vicente de Paula, Rio de Janeiro, RJ (Brazil). Servico de Radioterapia; Rossini Junior, Olamir [Clinica Radioterapia Botafogo Ltda., Rio de Janeiro, RJ (Brazil)

    2000-04-01

    We report the results of the treatment of four patients with inoperable meningiomas who underwent stereotactic radiosurgery using a linear accelerator of 6 MeV. Radiological examinations carried out from 12 to 22 months later revealed tumor growth arrest in all patients, giving a response rate of 100%. No early or late neurological complications dur to the radiosurgical treatment was observed. During the follow-up period no death caused by radiation was reported. Although the number of cases and the follow-up period were insufficient to show statistical significance, the results were satisfactory and thus require further investigations. (author)

  14. Geometrical and dosimetrical characterization of the photon source using a micro-multileaf collimator for stereotactic radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Treuer, H [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Hoevels, M [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Luyken, K [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Hunsche, S [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany); Kocher, M [Department of Radiotherapy, University of Cologne, Cologne (Germany); Mueller, R-P [Department of Radiotherapy, University of Cologne, Cologne (Germany); Sturm, V [Department of Stereotaxy and Functional Neurosurgery, University of Cologne, Cologne (Germany)

    2003-08-07

    A micro-multileaf collimator ({mu}MLC) for stereotactic radiosurgery is used for determination of the spatial intensity distribution of the photon source of a linear accelerator. The method is based on grid field dose measurements using film dosimetry and is easy to perform. Since the {mu}MLC does not allow 'direct' imaging of the photon source, special software has been developed to analyse grid field measurements. Besides the source-density function, grid field analysis yields the position of the focal spot in the room laser coordinate system of the linear accelerator and the position of the treatment head rotation axis and the inclination angle of the leaf bank. Thus the method can be used for base dosimetry and for quality assurance in radiosurgery using a {mu}MLC.

  15. Gamma Knife Radiosurgery for Acromegaly

    Directory of Open Access Journals (Sweden)

    John D. Rolston

    2012-01-01

    Full Text Available Acromegaly is debilitating disease occasionally refractory to surgical and medical treatment. Stereotactic radiosurgery, and in particular Gamma Knife surgery (GKS, has proven to be an effective noninvasive adjunct to traditional treatments, leading to disease remission in a substantial proportion of patients. Such remission holds the promise of eliminating the need for expensive medications, along with side effects, as well as sparing patients the damaging sequelae of uncontrolled acromegaly. Numerous studies of radiosurgical treatments for acromegaly have been carried out. These illustrate an overall remission rate over 40%. Morbidity from radiosurgery is infrequent but can include cranial nerve palsies and hypopituitarism. Overall, stereotactic radiosurgery is a promising therapy for patients with acromegaly and deserves further study to refine its role in the treatment of affected patients.

  16. Fractionated stereotactic radiation therapy and single high-dose radiosurgery for acoustic neuroma: early results of a prospective clinical study

    International Nuclear Information System (INIS)

    Meijer, O.W.M.; Wolbers, J.G.; Baayen, J.C.; Slotman, B.J.

    2000-01-01

    Purpose: To prospectively assess the local control and toxicity rate in acoustic neuroma patients treated with linear accelerator-based radiosurgery and fractionated stereotactic radiation therapy. Methods and Materials: We evaluated 37 consecutive patients treated with stereotactic radiation therapy for acoustic neuroma. All patients had progressive tumors, progressive symptoms, or both. Mean tumor diameter was 2.3 cm (range 0.8-3.3) on magnetic resonance (MR) scan. Dentate patients were given a dose of 5 x 4 Gy or 5 x 5 Gy and edentate patients were given a dose of 1 x 10 Gy or 1 x 12.50 Gy prescribed to the 80% isodose. All patients were treated with a single isocenter. Results: With a mean follow-up period of 25 months (range 12-61), the actuarial local control rate at 5 years was 91% (only 1 patient failed). The actuarial rate of hearing preservation at 5 years was 66% in previously-hearing patients. The actuarial rate of freedom from trigeminal nerve toxicity was 97% at 5 years. No patient developed facial nerve toxicity or other complications. Conclusion: In this unselected series, fractionated stereotactic radiation therapy and linear accelerator-based radiosurgery give excellent local control in acoustic neuroma. It combines a high rate of preservation of hearing with a very low rate of other toxicity, although follow-up is relatively short

  17. Robotic radiosurgery. Treating tumors that move with respiration

    International Nuclear Information System (INIS)

    Urschel, Harold C. Jr.; Kresl, John J.; Luketich, James D.; Papiez, Lech; Timmerman, Robert D.; Schulz, Raymond A.

    2007-01-01

    Addresses in detail all aspects of the use of robotic radiosurgery to treat tumors of the lung, liver, and pancreas Includes full consideration of tumor tracking techniques, dosimetry, radiobiology, and fiducial placement strategies Written by leading experts Includes many high quality illustrations Stereotactic radiosurgery continues to evolve in ways that allow this powerful technology to reach and treat more tumors in more patients. This volume in the Robotic Radiosurgery series is devoted to theory and practice in the emerging field of stereotactic radiosurgery (also called stereotactic body radiation therapy) for extracranial tumors, particularly those that move as patients breathe. The book is divided into six sections. The first three sections address tumor motion due to respiration and tumor tracking techniques; dosimetry, radiobiology, and imaging; and fiducial placement systems. The fourth and fifth sections then discuss in depth the use of robotic radiosurgery to treat lung and abdominal tumors, respectively, and a final section explains emerging concepts and techniques. Within this framework, detailed information is provided on the technology and methodology for delivery of high doses of radiation to moving targets, radiobiological and radiological principles, and the challenges faced by clinicians performing extracranial stereotactic radiosurgery. Furthermore, there are thorough reviews of the general clinical literature on stereotactic radiation treatment of tumors of the lungs, liver, and pancreas, and the latest clinical data from clinicians conducting clinical studies using the CyberKnife registered Robotic Radiosurgery System. Special attention is given to the frameless robotic radiosurgery device known as the CyberKnife, the only image-guided radiosurgery system that utilizes intelligent robotics to track, detect, and correct for changes in tumor position during treatments. Tumors that move with respiration are treated with the CyberKnife using a

  18. Robotic radiosurgery. Treating tumors that move with respiration

    Energy Technology Data Exchange (ETDEWEB)

    Urschel, Harold C. Jr. [Baylor University Medical Center, Dallas, TX (United States). Chair of Cardiovascular and Thoracic Surgical Research, Education and Clinical Excellence; Kresl, John J. [Arizona Oncology Services at St. Joseph' s Hospital and Medical Center, Phoenix, AZ (United States). Dept. of Radiation Oncology; Luketich, James D. [University of Pittsburgh Medical Center PUH, Pittsburgh, PA (United States). The Heart, Lung and Esophageal Surgery Inst.; Papiez, Lech; Timmerman, Robert D. [University of Texas Southwestern Medical Center, Dallas, TX (United States). Dept. of Radiation Oncology; Schulz, Raymond A. (eds.)

    2007-07-01

    Addresses in detail all aspects of the use of robotic radiosurgery to treat tumors of the lung, liver, and pancreas Includes full consideration of tumor tracking techniques, dosimetry, radiobiology, and fiducial placement strategies Written by leading experts Includes many high quality illustrations Stereotactic radiosurgery continues to evolve in ways that allow this powerful technology to reach and treat more tumors in more patients. This volume in the Robotic Radiosurgery series is devoted to theory and practice in the emerging field of stereotactic radiosurgery (also called stereotactic body radiation therapy) for extracranial tumors, particularly those that move as patients breathe. The book is divided into six sections. The first three sections address tumor motion due to respiration and tumor tracking techniques; dosimetry, radiobiology, and imaging; and fiducial placement systems. The fourth and fifth sections then discuss in depth the use of robotic radiosurgery to treat lung and abdominal tumors, respectively, and a final section explains emerging concepts and techniques. Within this framework, detailed information is provided on the technology and methodology for delivery of high doses of radiation to moving targets, radiobiological and radiological principles, and the challenges faced by clinicians performing extracranial stereotactic radiosurgery. Furthermore, there are thorough reviews of the general clinical literature on stereotactic radiation treatment of tumors of the lungs, liver, and pancreas, and the latest clinical data from clinicians conducting clinical studies using the CyberKnife {sup registered} Robotic Radiosurgery System. Special attention is given to the frameless robotic radiosurgery device known as the CyberKnife, the only image-guided radiosurgery system that utilizes intelligent robotics to track, detect, and correct for changes in tumor position during treatments. Tumors that move with respiration are treated with the Cyber

  19. Current signal of silicon detectors facing charged particles and heavy ions

    International Nuclear Information System (INIS)

    Hamrita, H.

    2005-07-01

    This work consisted in collecting and studying for the first time the shapes of current signals obtained from charged particles or heavy ions produced by silicon detectors. The document is divided into two main parts. The first consisted in reducing the experimental data obtained with charged particles as well as with heavy ions. These experiments were performed at the Orsay Tandem and at GANIL using LISE. These two experiments enabled us to create a data base formed of current signals with various shapes and various times of collection. The second part consisted in carrying out a simulation of the current signals obtained from the various ions. To obtain this simulation we propose a new model describing the formation of the signal. We used the data base of the signals obtained in experiments in order to constrain the three parameters of our model. In this model, the charge carriers created are regarded as dipoles and their density is related to the dielectric polarization in the silicon detector. This phenomenon induces an increase in permittivity throughout the range of the incident ion and consequently the electric field between the electrodes of the detector is decreased inside the trace. We coupled with this phenomenon a dissociation and extraction mode of the charge carriers so that they can be moved in the electric field. (author)

  20. CHARGE-2/C, Flux and Dose Behind Shield from Electron, Proton, Heavy Particle Irradiation

    International Nuclear Information System (INIS)

    Ucker, W.R.; Lilley, J.R.

    1994-01-01

    1 - Description of problem or function: The CHARGE code computes flux spectra, dose and other response rates behind a multilayered spherical or infinite planar shield exposed to isotopic fluxes of electrons, protons and heavy charged particles. The doses, or other responses, to electron, primary proton, heavy particle, electron Bremsstrahlung, secondary proton, and secondary neutron radiations are calculated as a function of penetration into the shield; the materials of each layer may be mixtures of elements contained in the accompanying data library, or supplied by the user. The calculation may optionally be halted before the entire shield is traversed by specifying a minimum total dose rate; the computation stops when the dose drops below this value. The ambient electron, proton and heavy particle spectra may be specified in tabular or functional form. These incident charged particle spectra are divided into energy bands or groups, the number or spacing of which are controlled by input data. The variation of the group boundary energies and group spectra as a function of shield penetration uniquely determines charged particle dose rates and secondary particle production rates. The charged particle shielding calculation is essentially the integration of the range- energy equation which expresses the variation of particle energy wit distance travelled. 2 - Method of solution: The 'straight-ahead' approximation is used throughout, that is the changes in particle direction of motion due to elastic scattering are ignored. This approximation is corrected, in the case of electrons, by applying transmission factors obtained from Monte Carlo calculations. Inelastic scattering between protons and the shielding material is assumed to produce two classes of secondaries 1) Cascade protons and neutrons, emitted in the same direction as the primaries 2) Evaporation neutrons, emitted isotropically. The transmission of secondary protons is analyzed in exactly the same way as the

  1. Evaluation of time, attendance of medical staff, and resources during stereotactic radiotherapy/radiosurgery. QUIRO-DEGRO trial

    Energy Technology Data Exchange (ETDEWEB)

    Zabel-du Bois, A.; Milker-Zabel, S.; Debus, J. [Heidelberg Univ. (Germany). Dept. of Radiotherapy and Radiooncology; Henzel, M.; Engenhart-Cabillic, R. [Marburg Univ. (Germany). Dept. of Radiotherapy and Radiation Oncology; Popp, W. [Prime Networks AG, Basel (Switzerland); Sack, H. [Essen Univ. (Germany). Dept. of Radiation Oncology

    2012-09-15

    Background: The German Society of Radiation Oncology ('Deutsche Gesellschaft fuer Radioonkologie', DEGRO) initiated a multicenter trial to develop and evaluate adequate modules to assert core processes and subprocesses in radiotherapy. The aim of this prospective evaluation was to methodical assess the required resources (technical equipment and medical staff) for stereotactic radiotherapy/radiosurgery. Material and methods: At two radiotherapy centers of excellence (University Hospitals of Heidelberg and Marburg/Giessen), the manpower and time required for the implementation of intra- and extracranial stereotactic radiotherapy was prospectively collected consistently over a 3-month period. The data were collected using specifically developed process acquisition tools and standard forms and were evaluated using specific process analysis tools. Results: For intracranial (extracranial) fractionated stereotactic radiotherapy (FSRT) and radiosurgery (RS), a total of 1,925 (270) and 199 (36) records, respectively, could be evaluated. The approximate time needed to customize the immobilization device was median 37 min (89 min) for FRST and 31 min (26 min) for RS, for the contrast enhanced planning studies 22 and 27 min (25 and 28 min), for physical treatment planning 122 and 59 min (187 and 27 min), for the first and routine radiotherapy sessions for FSRT 40 and 13 min (58 and 31 min), respectively. The median time needed for the RS session was 58 min (45 min). The corresponding minimal manpower needed was 2 technicians for customization of the immobilization device, 2.5 technicians and 1 consultant for the contrast-enhanced planning studies, 1 consultant, 0.5 resident and 0.67 medical physics expert (MPE) for physical treatment planning, as well as 1 consultant, 0.5 resident, and 2.5 technicians for the first radiotherapy treatment and 2.33 technicians for routine radiotherapy sessions. Conclusion: For the first time, the resource requirements for a

  2. Poster - Thur Eve - 50: Planning and delivery accuracy of stereotactic radiosurgery with Tomotherapy as compared to linear-accelerator and robotic based radiosurgery.

    Science.gov (United States)

    Thakur, V; Soisson, E; Ruo, R; Doucet, R; Parker, W; Seuntjens, J

    2012-07-01

    This study includes planning and delivery comparison of three stereotactic radiosurgery techniques : Helical Tomotherapy (HT), circular collimator-based Linear-accelerator and robotic-radiosurgery. Plans were generated for two spherical targets of diameter 6 mm and 10 mm contoured at the center of a Lucite phantom, using similar planning constrains. Planning comparison showed that average conformality (0-1best) for Linear-accelerator, robotic-radiosurgery and HT was 1.43, 1.24, and 1.77 and gradient index (less is better) was 2.72, 4.50 and 13.56 respectively. For delivery comparison, plans were delivered to radiochromic film and measured dose was compared with the planned dose. For Linear-accelerator and robotic-radiosurgery more than 99% pixels-passing a gamma criteria of 3% dose difference and 1 mm distance to agreement where as for HT this value was as low as 40% for off-axis targets. Further investigation of the delivery accuracy as a function of the location of the target with in the bore was initiated using small volume A1SL (0.057 cm 3 ) and MicroLion liquid ion chamber (0.0017 cm 3 ). Point dose measurements for targets located at the center and 10 cm away from the center of the bore showed that delivered dose varied by more than 15% for targets placed away from the center of the bore as opposed to at the center. In conclusion, Linear-accelerator and the robotic-radiosurgery techniques showed preferable gradient and conformality. For HT, point dose measurements were significantly lower than predicted by the TPS when the target was positioned away from the isocenter, while they were found to be higher at isocenter. © 2012 American Association of Physicists in Medicine.

  3. A round-robin gamma stereotactic radiosurgery dosimetry interinstitution comparison of calibration protocols

    Energy Technology Data Exchange (ETDEWEB)

    Drzymala, R. E., E-mail: drzymala@wustl.edu [Department of Radiation Oncology, Washington University, St. Louis, Missouri 63110 (United States); Alvarez, P. E. [Imaging and Radiation Oncology Core Houston, UT MD Anderson Cancer Center, Houston, Texas 77030 (United States); Bednarz, G. [Radiation Oncology Department, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania 15232 (United States); Bourland, J. D. [Department of Radiation Oncology, Wake Forest University, Winston-Salem, North Carolina 27157 (United States); DeWerd, L. A. [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States); Ma, L. [Department of Radiation Oncology, University California San Francisco, San Francisco, California 94143 (United States); Meltsner, S. G. [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Neyman, G. [Department of Radiation Oncology, The Cleveland Clinic Foundation, Cleveland, Ohio 44195 (United States); Novotny, J. [Medical Physics Department, Hospital Na Homolce, Prague 15030 (Czech Republic); Petti, P. L. [Gamma Knife Center, Washington Hospital Healthcare System, Fremont, California 94538 (United States); Rivard, M. J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Shiu, A. S. [Department of Radiation Oncology, University of Southern California, Los Angeles, California 90033 (United States); Goetsch, S. J. [San Diego Medical Physics, Inc., La Jolla, California 92037 (United States)

    2015-11-15

    Purpose: Absorbed dose calibration for gamma stereotactic radiosurgery is challenging due to the unique geometric conditions, dosimetry characteristics, and nonstandard field size of these devices. Members of the American Association of Physicists in Medicine (AAPM) Task Group 178 on Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance have participated in a round-robin exchange of calibrated measurement instrumentation and phantoms exploring two approved and two proposed calibration protocols or formalisms on ten gamma radiosurgery units. The objectives of this study were to benchmark and compare new formalisms to existing calibration methods, while maintaining traceability to U.S. primary dosimetry calibration laboratory standards. Methods: Nine institutions made measurements using ten gamma stereotactic radiosurgery units in three different 160 mm diameter spherical phantoms [acrylonitrile butadiene styrene (ABS) plastic, Solid Water, and liquid water] and in air using a positioning jig. Two calibrated miniature ionization chambers and one calibrated electrometer were circulated for all measurements. Reference dose-rates at the phantom center were determined using the well-established AAPM TG-21 or TG-51 dose calibration protocols and using two proposed dose calibration protocols/formalisms: an in-air protocol and a formalism proposed by the International Atomic Energy Agency (IAEA) working group for small and nonstandard radiation fields. Each institution’s results were normalized to the dose-rate determined at that institution using the TG-21 protocol in the ABS phantom. Results: Percentages of dose-rates within 1.5% of the reference dose-rate (TG-21 + ABS phantom) for the eight chamber-protocol-phantom combinations were the following: 88% for TG-21, 70% for TG-51, 93% for the new IAEA nonstandard-field formalism, and 65% for the new in-air protocol. Averages and standard deviations for dose-rates over all measurements relative to the TG-21 + ABS

  4. Summary report on first research coordination meeting on heavy charged-particle interaction data for radiotherapy

    International Nuclear Information System (INIS)

    Palmans, H.; Noy, R.C.

    2008-04-01

    A summary is given of the First Research Coordination Meeting on Heavy Charged-Particle Interaction Data for Radiotherapy. A programme to compile and evaluate charged-particle nuclear data for therapeutic applications was proposed. Detailed coordinated research proposals were also agreed. Technical discussions and the resulting work plan of the Coordinated Research Project are summarized, along with actions and deadlines. (author)

  5. Early changes in volume and non-enhanced volume of acoustic neurinoma after stereotactic gamma-radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Hirofumi; Kobayashi, Tatsuya; Kida, Yoshihisa; Tanaka, Takayuki; Mori, Yoshimasa; Iwakoshi, Takayasu; Niwa, Masahiro; Kai, Osamu; Hirose, Mitsuhiko [Komaki City Hospital, Aichi (Japan)

    1994-09-01

    The effectiveness of stereotactic gamma-radiosurgery for treating acoustic neurinoma was evaluated by measuring the volumes of the tumor, non-enhanced tumor, and cerebellar edema in 13 patients with acoustic neurinoma who were followed up for 9 to 15 months (median 12.7 mos) after treatment. The tumor volume and non-enhanced volume tended to reach a maximum after 6 months, and cerebellar edema volume after 9 months, then decreased gradually thereafter. Hearing loss tended to increase gradually, but involvement of the facial nerve was transient. (author).

  6. Technical Note: Evaluation of the systematic accuracy of a frameless, multiple image modality guided, linear accelerator based stereotactic radiosurgery system

    Energy Technology Data Exchange (ETDEWEB)

    Wen, N., E-mail: nwen1@hfhs.org; Snyder, K. C.; Qin, Y.; Li, H.; Siddiqui, M. S.; Chetty, I. J. [Department of Radiation Oncology, Henry Ford Health System, 2799 West Brand Boulevard, Detroit, Michigan 48202 (United States); Scheib, S. G.; Schmelzer, P. [Varian Medical System, Täfernstrasse 7, Dättwil AG 5405 (Switzerland)

    2016-05-15

    Purpose: To evaluate the total systematic accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy and intermodality difference was determined by delivering radiation to an end-to-end prototype phantom, in which the targets were localized using optical surface monitoring system (OSMS), electromagnetic beacon-based tracking (Calypso®), cone-beam CT, “snap-shot” planar x-ray imaging, and a robotic couch. Six IMRT plans with jaw tracking and a flattening filter free beam were used to study the dosimetric accuracy for intracranial and spinal stereotactic radiosurgery treatment. Results: End-to-end localization accuracy of the system evaluated with the end-to-end phantom was 0.5 ± 0.2 mm with a maximum deviation of 0.9 mm over 90 measurements (including jaw, MLC, and cone measurements for both auto and manual fusion) for single isocenter, single target treatment, 0.6 ± 0.4 mm for multitarget treatment with shared isocenter. Residual setup errors were within 0.1 mm for OSMS, and 0.3 mm for Calypso. Dosimetric evaluation based on absolute film dosimetry showed greater than 90% pass rate for all cases using a gamma criteria of 3%/1 mm. Conclusions: The authors’ experience demonstrates that the localization accuracy of the frameless image-guided system is comparable to robotic or invasive frame based radiosurgery systems.

  7. Technical Note: Evaluation of the systematic accuracy of a frameless, multiple image modality guided, linear accelerator based stereotactic radiosurgery system

    International Nuclear Information System (INIS)

    Wen, N.; Snyder, K. C.; Qin, Y.; Li, H.; Siddiqui, M. S.; Chetty, I. J.; Scheib, S. G.; Schmelzer, P.

    2016-01-01

    Purpose: To evaluate the total systematic accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy and intermodality difference was determined by delivering radiation to an end-to-end prototype phantom, in which the targets were localized using optical surface monitoring system (OSMS), electromagnetic beacon-based tracking (Calypso®), cone-beam CT, “snap-shot” planar x-ray imaging, and a robotic couch. Six IMRT plans with jaw tracking and a flattening filter free beam were used to study the dosimetric accuracy for intracranial and spinal stereotactic radiosurgery treatment. Results: End-to-end localization accuracy of the system evaluated with the end-to-end phantom was 0.5 ± 0.2 mm with a maximum deviation of 0.9 mm over 90 measurements (including jaw, MLC, and cone measurements for both auto and manual fusion) for single isocenter, single target treatment, 0.6 ± 0.4 mm for multitarget treatment with shared isocenter. Residual setup errors were within 0.1 mm for OSMS, and 0.3 mm for Calypso. Dosimetric evaluation based on absolute film dosimetry showed greater than 90% pass rate for all cases using a gamma criteria of 3%/1 mm. Conclusions: The authors’ experience demonstrates that the localization accuracy of the frameless image-guided system is comparable to robotic or invasive frame based radiosurgery systems.

  8. Clinical results of LINAC-based stereotactic radiosurgery for pituitary adenoma

    International Nuclear Information System (INIS)

    Muramatsu, Julia; Yoshida, Masanori; Shioura, Hiroki; Kawamura, Yasutaka; Ito, Harumi; Takeuchi, Hiroaki; Kubota, Toshihiko; Maruyama, Ichiro

    2003-01-01

    We retrospectively evaluated our clinical results of stereotactic radiosurgery (SRS) for pituitary adenoma. Between 1995 and 2000, 13 patients were treated with SRS for pituitary adenoma. In all cases, the tumors had already been surgically resected. The adenomas were functional in 5 and non-functional in 8 patients. The median follow-up period was 30 months. SRS was performed with the use of a dedicated stereotactic 10-MV linear accelerator (LINAC). The median dose to the tumor margin was 15 Gy. The dose to the optic apparatus was limited to less than 8 Gy. MR images of 12 patients revealed tumor complete response (CR) in one case and partial response (PR) in 9 cases; in the remaining two patients, tumor size decreased by less than 50%. There was no recognizable regrowth of any of the tumors. In two of four GH-secreting adenomas, hormonal overproduction normalized, while the other two showed reduced hormonal production. One PRL-secreting adenoma did not respond. Reduction of visual acuity and field was seen in one patient. This patient also had a brain infarction. None of the patients developed brain radionecrosis or radiation-induced hypopituitarism. Although further studies based on greater numbers of cases and longer follow-up periods are needed, our results suggest that SRS seems to be a safe, effective treatment for pituitary adenoma. (author)

  9. Factors influencing local control and survival for patients undergoing stereotactic radiosurgery for intracranial metastases

    International Nuclear Information System (INIS)

    Suh, John H.; Barnett, Gene H.; Sohn, Jason W.; Fernandez-Vicioso, Eduardo; Kupelian, Patrick A.

    1996-01-01

    PURPOSE: To identify factors affecting local control and survival for patients undergoing stereotactic radiosurgery for intracranial metastases. MATERIALS AND METHODS: From 3/90-10/95, 99 patients (median age 58, range 29-83; 44 women, 55 men) with asymptomatic or mildly symptomatic intracranial metastases measuring < 4 cm in diameter and ≥ 1 cm from optic chiasm and Karnofsky Performance Status (KPS) ≥ 70 underwent modified linear accelerator-based stereotactic radiosurgery (SRS). Patients characteristics included 20 with recurrent disease, 66 with solitary lesions, and 42 with systemic disease. Forty six patients underwent surgical resection prior to SRS (16 biopsy, 3 subtotal resection (STR), and 21 gross total resection (GTR)). Eighty of 99 patients underwent whole brain radiation treatments (median 4005 cGy/15 fx, range 2200-6000 cGy). A total of 154 lesions were treated with 143 being evaluable on follow-up CT or MRI scans. Radiosurgery parameters (median) were the following: volume 2.8 cc (range 0.1-38 cc) and a peripheral dose of 1700 cGy (range 500-2400 cGy) with normalization to the 80% line (range 50-90%). Survival was measured from the date of SRS. Local control was defined as stabilization or decrease in size of the intracranial lesion(s). RESULTS: The following factors were analyzed with respect to local control and survival: 1) solitary vs. multiple lesions, 2) Age < or ≥ 60, 3) sex, 4) radiosensitive vs. radioresistant (renal cell and melanoma) histologies, 5) recurrent vs. newly diagnosed lesions, 6) KPS (70-80 vs. 90-100), 7) extent of surgery (biopsy vs. STR/GTR), 8) use of whole brain radiation treatments, 9) absence or presence of systemic disease, 10) dose (< or ≥ 1500 cGy) and 11) volume (< or ≥ 3 cc). On univariate analysis, survival was significantly influenced by female sex, presence of solitary lesion, absence of systemic disease, and extent of surgery. On multivariate analysis, female sex (p=0.0037), absence of systemic disease

  10. Heavy charged particle therapy

    International Nuclear Information System (INIS)

    Mizoe, Jun-etsu

    1995-01-01

    A pilot study of heavy charged particles with heavy ion medical accelerator in Chiba (HIMAC) for advanced H and N cancer has been carried out from June 1994 at National Institute of Radiological Sciences (NIRS). As of the beginning of August 1994, three patients were treated by 290 MeV carbon ions. The patients had adenocarcinoma of the cheek mucosa, squamous cell carcinoma of the ethmoid sinus and adenoid cystic carcinoma of the sublingual gland. Patients were immobilized by individual head coach and thermosplint facial shell. Individual collimators and bolus were also prepared for each ports. Dose fractionation for the initial pilot study group was 16.2 GyE/18 fractions/6 weeks, which would be equivalent to standard fractionation of 60.0 Gy/30 fractions/6 weeks with photons. This dose fractionation was considered to be 20% lesser than 75 GyE/37.5 fractions/7.5 weeks, which is estimated to be maximum tolerance dose for advanced H and N cancers. HIMAC worked well and there was no major trouble causing any treatment delay. Acute skin reactions of 3 patients were 2 cases of bright erythema with patchy moist desquamation and one of dull erythema, which were evaluated as equivalent reaction with irradiated dose. Acute mucosa reactions appeared to have lesser reaction than predicted mucositis. Tumor reactions of three patients were partial reaction (PR) at the end of treatment and nearly complete remission (CR) after 6 months of treatment. From October 1994, we started to treat patients with advanced H and N cancer with 10% high dose than previous dose. And new candidates of pilot study with non small cell lung cancer, brain tumor and carcinoma of the tongue were entered into pilot study. At the end of February 1995, a total of 21 patients were treated by carbon ions. (J.P.N.)

  11. Impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans

    International Nuclear Information System (INIS)

    Kubo, H. Dale; Wilder, Richard B.; Pappas, Conrad T.E.

    1999-01-01

    Purpose: The authors undertook a study to analyze the impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans. Methods and Materials: Twelve cases involving primary brain tumors, metastases, or arteriovenous malformations that had been planned with BrainLAB's conventional circular collimator-based radiosurgery system were re-planned using a β-version of BrainLAB's treatment planning software that is compatible with MRC Systems' and BrainLAB's micro-multileaf collimators. These collimators have a minimum leaf width of 1.7 mm and 3.0 mm, respectively, at isocenter. The clinical target volumes ranged from 2.7-26.1 cc and the number of static fields ranged from 3-5. In addition, for 4 prostate cancer cases, 2 separate clinical target volumes were planned using MRC Systems' and BrainLAB's micro-multileaf collimators and Varian's multileaf collimator: the smaller clinical target volume consisted of the prostate gland and the larger clinical target volume consisted of the prostate and seminal vesicles. For the prostate cancer cases, treatment plans were generated using either 6 or 7 static fields. A 'PITV ratio', which the Radiation Therapy Oncology Group defines as the volume encompassed by the prescription isodose surface divided by the clinical target volume, was used as a measure of the quality of treatment plans (a PITV ratio of 1.0-2.0 is desirable). Bladder and rectal volumes encompassed by the prescription isodose surface, isodose distributions and dose volume histograms were also analyzed for the prostate cancer patients. Results: In 75% of the cases treated with radiosurgery, a PITV ratio between 1.0-2.0 could be achieved using a micro-multileaf collimator with a leaf width of 1.7-3.0 mm at isocenter and 3-5 static fields. When the clinical target volume consisted of the prostate gland, the micro-multileaf collimator with a minimum leaf width of 3.0 mm allowed one to decrease the median volume of bladder and

  12. Search for Heavy Stable Charged Particles in pp collisions at $\\sqrt{s}$ = 7 TeV

    CERN Document Server

    Khachatryan, Vardan; Tumasyan, Armen; Adam, Wolfgang; Bergauer, Thomas; Dragicevic, Marko; Erö, Janos; Fabjan, Christian; Friedl, Markus; Fruehwirth, Rudolf; Ghete, Vasile Mihai; Hammer, Josef; Haensel, Stephan; Hartl, Christian; Hoch, Michael; Hörmann, Natascha; Hrubec, Josef; Jeitler, Manfred; Kasieczka, Gregor; Kiesenhofer, Wolfgang; Krammer, Manfred; Liko, Dietrich; Mikulec, Ivan; Pernicka, Manfred; Rohringer, Herbert; Schöfbeck, Robert; Strauss, Josef; Taurok, Anton; Teischinger, Florian; Waltenberger, Wolfgang; Walzel, Gerhard; Widl, Edmund; Wulz, Claudia-Elisabeth; Mossolov, Vladimir; Shumeiko, Nikolai; Suarez Gonzalez, Juan; Benucci, Leonardo; Ceard, Ludivine; Cerny, Karel; De Wolf, Eddi A.; Janssen, Xavier; Maes, Thomas; Mucibello, Luca; Ochesanu, Silvia; Roland, Benoit; Rougny, Romain; Selvaggi, Michele; Van Haevermaet, Hans; Van Mechelen, Pierre; Van Remortel, Nick; Adler, Volker; Beauceron, Stephanie; Blekman, Freya; Blyweert, Stijn; D'Hondt, Jorgen; Devroede, Olivier; Gonzalez Suarez, Rebeca; Kalogeropoulos, Alexis; Maes, Joris; Maes, Michael; Tavernier, Stefaan; Van Doninck, Walter; Van Mulders, Petra; Van Onsem, Gerrit Patrick; Villella, Ilaria; Charaf, Otman; Clerbaux, Barbara; De Lentdecker, Gilles; Dero, Vincent; Gay, Arnaud; Hammad, Gregory Habib; Hreus, Tomas; Marage, Pierre Edouard; Thomas, Laurent; Vander Velde, Catherine; Vanlaer, Pascal; Wickens, John; Costantini, Silvia; Grunewald, Martin; Klein, Benjamin; Marinov, Andrey; Mccartin, Joseph; Ryckbosch, Dirk; Thyssen, Filip; Tytgat, Michael; Vanelderen, Lukas; Verwilligen, Piet; Walsh, Sinead; Zaganidis, Nicolas; Basegmez, Suzan; Bruno, Giacomo; Caudron, Julien; De Favereau De Jeneret, Jerome; Delaere, Christophe; Demin, Pavel; Favart, Denis; Giammanco, Andrea; Grégoire, Ghislain; Hollar, Jonathan; Lemaitre, Vincent; Liao, Junhui; Militaru, Otilia; Ovyn, Severine; Pagano, Davide; Pin, Arnaud; Piotrzkowski, Krzysztof; Quertenmont, Loic; Schul, Nicolas; Beliy, Nikita; Caebergs, Thierry; Daubie, Evelyne; Alves, Gilvan; De Jesus Damiao, Dilson; Pol, Maria Elena; Henrique Gomes E Souza, Moacyr; Carvalho, Wagner; Melo Da Costa, Eliza; De Oliveira Martins, Carley; Fonseca De Souza, Sandro; Mundim, Luiz; Nogima, Helio; Oguri, Vitor; Prado Da Silva, Wanda Lucia; Santoro, Alberto; Silva Do Amaral, Sheila Mara; Sznajder, Andre; De Almeida Dias, Flavia; Ferreira Dias, Marco Andre; Tomei, Thiago; De Moraes Gregores, Eduardo; Da Cunha Marinho, Franciole; Novaes, Sergio F.; Padula, Sandra; Darmenov, Nikolay; Dimitrov, Lubomir; Genchev, Vladimir; Iaydjiev, Plamen; Piperov, Stefan; Rodozov, Mircho; Stoykova, Stefka; Sultanov, Georgi; Tcholakov, Vanio; Trayanov, Rumen; Vankov, Ivan; Dyulendarova, Milena; Hadjiiska, Roumyana; Kozhuharov, Venelin; Litov, Leander; Marinova, Evelina; Mateev, Matey; Pavlov, Borislav; Petkov, Peicho; Bian, Jian-Guo; Chen, Guo-Ming; Chen, He-Sheng; Jiang, Chun-Hua; Liang, Dong; Liang, Song; Wang, Jian; Wang, Jian; Wang, Xianyou; Wang, Zheng; Xu, Ming; Yang, Min; Zang, Jingjing; Zhang, Zhen; Ban, Yong; Guo, Shuang; Li, Wenbo; Mao, Yajun; Qian, Si-Jin; Teng, Haiyun; Zhang, Linlin; Zhu, Bo; Cabrera, Andrés; Gomez Moreno, Bernardo; Ocampo Rios, Alberto Andres; Osorio Oliveros, Andres Felipe; Sanabria, Juan Carlos; Godinovic, Nikola; Lelas, Damir; Lelas, Karlo; Plestina, Roko; Polic, Dunja; Puljak, Ivica; Antunovic, Zeljko; Dzelalija, Mile; Brigljevic, Vuko; Duric, Senka; Kadija, Kreso; Morovic, Srecko; Attikis, Alexandros; Galanti, Mario; Mousa, Jehad; Nicolaou, Charalambos; Ptochos, Fotios; Razis, Panos A.; Rykaczewski, Hans; Assran, Yasser; Mahmoud, Mohammed; Hektor, Andi; Kadastik, Mario; Kannike, Kristjan; Müntel, Mait; Raidal, Martti; Rebane, Liis; Azzolini, Virginia; Eerola, Paula; Czellar, Sandor; Härkönen, Jaakko; Heikkinen, Mika Aatos; Karimäki, Veikko; Kinnunen, Ritva; Klem, Jukka; Kortelainen, Matti J.; Lampén, Tapio; Lassila-Perini, Kati; Lehti, Sami; Lindén, Tomas; Luukka, Panja-Riina; Mäenpää, Teppo; Tuominen, Eija; Tuominiemi, Jorma; Tuovinen, Esa; Ungaro, Donatella; Wendland, Lauri; Banzuzi, Kukka; Korpela, Arja; Tuuva, Tuure; Sillou, Daniel; Besancon, Marc; Choudhury, Somnath; Dejardin, Marc; Denegri, Daniel; Fabbro, Bernard; Faure, Jean-Louis; Ferri, Federico; Ganjour, Serguei; Gentit, François-Xavier; Givernaud, Alain; Gras, Philippe; Hamel de Monchenault, Gautier; Jarry, Patrick; Locci, Elizabeth; Malcles, Julie; Marionneau, Matthieu; Millischer, Laurent; Rander, John; Rosowsky, André; Shreyber, Irina; Titov, Maksym; Verrecchia, Patrice; Baffioni, Stephanie; Beaudette, Florian; Bianchini, Lorenzo; Bluj, Michal; Broutin, Clementine; Busson, Philippe; Charlot, Claude; Dahms, Torsten; Dobrzynski, Ludwik; Granier de Cassagnac, Raphael; Haguenauer, Maurice; Miné, Philippe; Mironov, Camelia; Ochando, Christophe; Paganini, Pascal; Sabes, David; Salerno, Roberto; Sirois, Yves; Thiebaux, Christophe; Wyslouch, Bolek; Zabi, Alexandre; Agram, Jean-Laurent; Andrea, Jeremy; Besson, Auguste; Bloch, Daniel; Bodin, David; Brom, Jean-Marie; Cardaci, Marco; Chabert, Eric Christian; Collard, Caroline; Conte, Eric; Drouhin, Frédéric; Ferro, Cristina; Fontaine, Jean-Charles; Gelé, Denis; Goerlach, Ulrich; Greder, Sebastien; Juillot, Pierre; Karim, Mehdi; Le Bihan, Anne-Catherine; Mikami, Yoshinari; Van Hove, Pierre; Fassi, Farida; Mercier, Damien; Baty, Clement; Beaupere, Nicolas; Bedjidian, Marc; Bondu, Olivier; Boudoul, Gaelle; Boumediene, Djamel; Brun, Hugues; Chanon, Nicolas; Chierici, Roberto; Contardo, Didier; Depasse, Pierre; El Mamouni, Houmani; Falkiewicz, Anna; Fay, Jean; Gascon, Susan; Ille, Bernard; Kurca, Tibor; Le Grand, Thomas; Lethuillier, Morgan; Mirabito, Laurent; Perries, Stephane; Sordini, Viola; Tosi, Silvano; Tschudi, Yohann; Verdier, Patrice; Xiao, Hong; Roinishvili, Vladimir; Anagnostou, Georgios; Edelhoff, Matthias; Feld, Lutz; Heracleous, Natalie; Hindrichs, Otto; Jussen, Ruediger; Klein, Katja; Merz, Jennifer; Mohr, Niklas; Ostapchuk, Andrey; Perieanu, Adrian; Raupach, Frank; Sammet, Jan; Schael, Stefan; Sprenger, Daniel; Weber, Hendrik; Weber, Martin; Wittmer, Bruno; Ata, Metin; Bender, Walter; Erdmann, Martin; Frangenheim, Jens; Hebbeker, Thomas; Hinzmann, Andreas; Hoepfner, Kerstin; Hof, Carsten; Klimkovich, Tatsiana; Klingebiel, Dennis; Kreuzer, Peter; Lanske, Dankfried; Magass, Carsten; Masetti, Gianni; Merschmeyer, Markus; Meyer, Arnd; Papacz, Paul; Pieta, Holger; Reithler, Hans; Schmitz, Stefan Antonius; Sonnenschein, Lars; Steggemann, Jan; Teyssier, Daniel; Bontenackels, Michael; Davids, Martina; Duda, Markus; Flügge, Günter; Geenen, Heiko; Giffels, Manuel; Haj Ahmad, Wael; Heydhausen, Dirk; Kress, Thomas; Kuessel, Yvonne; Linn, Alexander; Nowack, Andreas; Perchalla, Lars; Pooth, Oliver; Rennefeld, Jörg; Sauerland, Philip; Stahl, Achim; Thomas, Maarten; Tornier, Daiske; Zoeller, Marc Henning; Aldaya Martin, Maria; Behrenhoff, Wolf; Behrens, Ulf; Bergholz, Matthias; Borras, Kerstin; Cakir, Altan; Campbell, Alan; Castro, Elena; Dammann, Dirk; Eckerlin, Guenter; Eckstein, Doris; Flossdorf, Alexander; Flucke, Gero; Geiser, Achim; Glushkov, Ivan; Hauk, Johannes; Jung, Hannes; Kasemann, Matthias; Katkov, Igor; Katsas, Panagiotis; Kleinwort, Claus; Kluge, Hannelies; Knutsson, Albert; Krücker, Dirk; Kuznetsova, Ekaterina; Lange, Wolfgang; Lohmann, Wolfgang; Mankel, Rainer; Marienfeld, Markus; Melzer-Pellmann, Isabell-Alissandra; Meyer, Andreas Bernhard; Mnich, Joachim; Mussgiller, Andreas; Olzem, Jan; Parenti, Andrea; Raspereza, Alexei; Raval, Amita; Schmidt, Ringo; Schoerner-Sadenius, Thomas; Sen, Niladri; Stein, Matthias; Tomaszewska, Justyna; Volyanskyy, Dmytro; Walsh, Roberval; Wissing, Christoph; Autermann, Christian; Bobrovskyi, Sergei; Draeger, Jula; Enderle, Holger; Gebbert, Ulla; Kaschube, Kolja; Kaussen, Gordon; Klanner, Robert; Lange, Jörn; Mura, Benedikt; Naumann-Emme, Sebastian; Nowak, Friederike; Pietsch, Niklas; Sander, Christian; Schettler, Hannes; Schleper, Peter; Schröder, Matthias; Schum, Torben; Schwandt, Joern; Srivastava, Ajay Kumar; Stadie, Hartmut; Steinbrück, Georg; Thomsen, Jan; Wolf, Roger; Barth, Christian; Bauer, Julia; Buege, Volker; Chwalek, Thorsten; De Boer, Wim; Dierlamm, Alexander; Dirkes, Guido; Feindt, Michael; Gruschke, Jasmin; Hackstein, Christoph; Hartmann, Frank; Heindl, Stefan Michael; Heinrich, Michael; Held, Hauke; Hoffmann, Karl-Heinz; Honc, Simon; Kuhr, Thomas; Martschei, Daniel; Mueller, Steffen; Müller, Thomas; Niegel, Martin; Oberst, Oliver; Oehler, Andreas; Ott, Jochen; Peiffer, Thomas; Piparo, Danilo; Quast, Gunter; Rabbertz, Klaus; Ratnikov, Fedor; Renz, Manuel; Saout, Christophe; Scheurer, Armin; Schieferdecker, Philipp; Schilling, Frank-Peter; Schott, Gregory; Simonis, Hans-Jürgen; Stober, Fred-Markus Helmut; Troendle, Daniel; Wagner-Kuhr, Jeannine; Zeise, Manuel; Zhukov, Valery; Ziebarth, Eva Barbara; Daskalakis, Georgios; Geralis, Theodoros; Kesisoglou, Stilianos; Kyriakis, Aristotelis; Loukas, Demetrios; Manolakos, Ioannis; Markou, Athanasios; Markou, Christos; Mavrommatis, Charalampos; Petrakou, Eleni; Gouskos, Loukas; Mertzimekis, Theodoros; Panagiotou, Apostolos; Evangelou, Ioannis; Foudas, Costas; Kokkas, Panagiotis; Manthos, Nikolaos; Papadopoulos, Ioannis; Patras, Vaios; Triantis, Frixos A.; Aranyi, Attila; Bencze, Gyorgy; Boldizsar, Laszlo; Debreczeni, Gergely; Hajdu, Csaba; Horvath, Dezso; Kapusi, Anita; Krajczar, Krisztian; Laszlo, Andras; Sikler, Ferenc; Vesztergombi, Gyorgy; Beni, Noemi; Molnar, Jozsef; Palinkas, Jozsef; Szillasi, Zoltan; Veszpremi, Viktor; Raics, Peter; Trocsanyi, Zoltan Laszlo; Ujvari, Balazs; Bansal, Sunil; Beri, Suman Bala; Bhatnagar, Vipin; Dhingra, Nitish; Jindal, Monika; Kaur, Manjit; Kohli, Jatinder Mohan; Mehta, Manuk Zubin; Nishu, Nishu; Saini, Lovedeep Kaur; Sharma, Archana; Singh, Anil; Singh, Jas Bir; Singh, Supreet Pal; Ahuja, Sudha; Bhattacharya, Satyaki; Choudhary, Brajesh C.; Gupta, Pooja; Jain, Sandhya; Jain, Shilpi; Kumar, Ashok; Shivpuri, Ram Krishen; Choudhury, Rajani Kant; Dutta, Dipanwita; Kailas, Swaminathan; Kataria, Sushil Kumar; Mohanty, Ajit Kumar; Pant, Lalit Mohan; Shukla, Prashant; Aziz, Tariq; Guchait, Monoranjan; Gurtu, Atul; Maity, Manas; Majumder, Devdatta; Majumder, Gobinda; Mazumdar, Kajari; Mohanty, Gagan Bihari; Saha, Anirban; Sudhakar, Katta; Wickramage, Nadeesha; Banerjee, Sudeshna; Dugad, Shashikant; Mondal, Naba Kumar; Arfaei, Hessamaddin; Bakhshiansohi, Hamed; Etesami, Seyed Mohsen; Fahim, Ali; Hashemi, Majid; Jafari, Abideh; Khakzad, Mohsen; Mohammadi, Abdollah; Mohammadi Najafabadi, Mojtaba; Paktinat Mehdiabadi, Saeid; Safarzadeh, Batool; Zeinali, Maryam; Abbrescia, Marcello; Barbone, Lucia; Calabria, Cesare; Colaleo, Anna; Creanza, Donato; De Filippis, Nicola; De Palma, Mauro; Dimitrov, Anton; Fiore, Luigi; Iaselli, Giuseppe; Lusito, Letizia; Maggi, Giorgio; Maggi, Marcello; Manna, Norman; Marangelli, Bartolomeo; My, Salvatore; Nuzzo, Salvatore; Pacifico, Nicola; Pierro, Giuseppe Antonio; Pompili, Alexis; Pugliese, Gabriella; Romano, Francesco; Roselli, Giuseppe; Selvaggi, Giovanna; Silvestris, Lucia; Trentadue, Raffaello; Tupputi, Salvatore; Zito, Giuseppe; Abbiendi, Giovanni; Benvenuti, Alberto; Bonacorsi, Daniele; Braibant-Giacomelli, Sylvie; Brigliadori, Luca; Capiluppi, Paolo; Castro, Andrea; Cavallo, Francesca Romana; Cuffiani, Marco; Dallavalle, Gaetano-Marco; Fabbri, Fabrizio; Fanfani, Alessandra; Fasanella, Daniele; Giacomelli, Paolo; Giunta, Marina; Marcellini, Stefano; Meneghelli, Marco; Montanari, Alessandro; Navarria, Francesco; Odorici, Fabrizio; Perrotta, Andrea; Primavera, Federica; Rossi, Antonio; Rovelli, Tiziano; Siroli, Gianni; Travaglini, Riccardo; Albergo, Sebastiano; Cappello, Gigi; Chiorboli, Massimiliano; Costa, Salvatore; Tricomi, Alessia; Tuve, Cristina; Barbagli, Giuseppe; Ciulli, Vitaliano; Civinini, Carlo; D'Alessandro, Raffaello; Focardi, Ettore; Frosali, Simone; Gallo, Elisabetta; Genta, Chiara; Lenzi, Piergiulio; Meschini, Marco; Paoletti, Simone; Sguazzoni, Giacomo; Tropiano, Antonio; Benussi, Luigi; Bianco, Stefano; Colafranceschi, Stefano; Fabbri, Franco; Piccolo, Davide; Fabbricatore, Pasquale; Musenich, Riccardo; Benaglia, Andrea; De Guio, Federico; Di Matteo, Leonardo; Ghezzi, Alessio; Malberti, Martina; Malvezzi, Sandra; Martelli, Arabella; Massironi, Andrea; Menasce, Dario; Moroni, Luigi; Paganoni, Marco; Pedrini, Daniele; Ragazzi, Stefano; Redaelli, Nicola; Sala, Silvano; Tabarelli de Fatis, Tommaso; Tancini, Valentina; Buontempo, Salvatore; Carrillo Montoya, Camilo Andres; Cimmino, Anna; De Cosa, Annapaola; De Gruttola, Michele; Fabozzi, Francesco; Iorio, Alberto Orso Maria; Lista, Luca; Merola, Mario; Noli, Pasquale; Paolucci, Pierluigi; Azzi, Patrizia; Bacchetta, Nicola; Bellan, Paolo; Bisello, Dario; Branca, Antonio; Carlin, Roberto; Conti, Enrico; De Mattia, Marco; Dorigo, Tommaso; Fanzago, Federica; Gasparini, Fabrizio; Giubilato, Piero; Gonella, Franco; Gresele, Ambra; Lacaprara, Stefano; Lazzizzera, Ignazio; Margoni, Martino; Mazzucato, Mirco; Meneguzzo, Anna Teresa; Nespolo, Massimo; Pegoraro, Matteo; Perrozzi, Luca; Pozzobon, Nicola; Ronchese, Paolo; Torassa, Ezio; Tosi, Mia; Triossi, Andrea; Vanini, Sara; Ventura, Sandro; Zumerle, Gianni; Baesso, Paolo; Berzano, Umberto; Riccardi, Cristina; Torre, Paola; Vitulo, Paolo; Viviani, Claudio; Biasini, Maurizio; Bilei, Gian Mario; Caponeri, Benedetta; Fanò, Livio; Lariccia, Paolo; Lucaroni, Andrea; Mantovani, Giancarlo; Menichelli, Mauro; Nappi, Aniello; Santocchia, Attilio; Servoli, Leonello; Taroni, Silvia; Valdata, Marisa; Volpe, Roberta; Azzurri, Paolo; Bagliesi, Giuseppe; Bernardini, Jacopo; Boccali, Tommaso; Broccolo, Giuseppe; Castaldi, Rino; D'Agnolo, Raffaele Tito; Dell'Orso, Roberto; Fiori, Francesco; Foà, Lorenzo; Giassi, Alessandro; Kraan, Aafke; Ligabue, Franco; Lomtadze, Teimuraz; Martini, Luca; Messineo, Alberto; Palla, Fabrizio; Palmonari, Francesco; Sarkar, Subir; Segneri, Gabriele; Serban, Alin Titus; Spagnolo, Paolo; Tenchini, Roberto; Tonelli, Guido; Venturi, Andrea; Verdini, Piero Giorgio; Barone, Luciano; Cavallari, Francesca; Del Re, Daniele; Di Marco, Emanuele; Diemoz, Marcella; Franci, Daniele; Grassi, Marco; Longo, Egidio; Organtini, Giovanni; Palma, Alessandro; Pandolfi, Francesco; Paramatti, Riccardo; Rahatlou, Shahram; Amapane, Nicola; Arcidiacono, Roberta; Argiro, Stefano; Arneodo, Michele; Biino, Cristina; Botta, Cristina; Cartiglia, Nicolo; Castello, Roberto; Costa, Marco; Demaria, Natale; Graziano, Alberto; Mariotti, Chiara; Marone, Matteo; Maselli, Silvia; Migliore, Ernesto; Mila, Giorgia; Monaco, Vincenzo; Musich, Marco; Obertino, Maria Margherita; Pastrone, Nadia; Pelliccioni, Mario; Romero, Alessandra; Ruspa, Marta; Sacchi, Roberto; Sola, Valentina; Solano, Ada; Staiano, Amedeo; Trocino, Daniele; Vilela Pereira, Antonio; Ambroglini, Filippo; Belforte, Stefano; Cossutti, Fabio; Della Ricca, Giuseppe; Gobbo, Benigno; Montanino, Damiana; Penzo, Aldo; Heo, Seong Gu; Chang, Sunghyun; Chung, Jin Hyuk; Kim, Dong Hee; Kim, Gui Nyun; Kim, Ji Eun; Kong, Dae Jung; Park, Hyangkyu; Son, Dohhee; Son, Dong-Chul; Kim, Jaeho; Kim, Jae Yool; Song, Sanghyeon; Choi, Suyong; Hong, Byung-Sik; Jo, Mihee; Kim, Hyunchul; Kim, Ji Hyun; Kim, Tae Jeong; Lee, Kyong Sei; Moon, Dong Ho; Park, Sung Keun; Rhee, Han-Bum; Seo, Eunsung; Shin, Seungsu; Sim, Kwang Souk; Choi, Minkyoo; Kang, Seokon; Kim, Hyunyong; Park, Chawon; Park, Inkyu; Park, Sangnam; Ryu, Geonmo; Choi, Young-Il; Choi, Young Kyu; Goh, Junghwan; Lee, Jongseok; Lee, Sungeun; Seo, Hyunkwan; Yu, Intae; Bilinskas, Mykolas Jurgis; Grigelionis, Ignas; Janulis, Mindaugas; Martisiute, Dalia; Petrov, Pavel; Sabonis, Tomas; Castilla Valdez, Heriberto; De La Cruz Burelo, Eduard; Lopez-Fernandez, Ricardo; Sánchez Hernández, Alberto; Villasenor-Cendejas, Luis Manuel; Carrillo Moreno, Salvador; Vazquez Valencia, Fabiola; Salazar Ibarguen, Humberto Antonio; Casimiro Linares, Edgar; Morelos Pineda, Antonio; Reyes-Santos, Marco A.; Allfrey, Philip; Krofcheck, David; Butler, Philip H.; Doesburg, Robert; Silverwood, Hamish; Ahmad, Muhammad; Ahmed, Ijaz; Asghar, Muhammad Irfan; Hoorani, Hafeez R.; Khan, Wajid Ali; Khurshid, Taimoor; Qazi, Shamona; Cwiok, Mikolaj; Dominik, Wojciech; Doroba, Krzysztof; Kalinowski, Artur; Konecki, Marcin; Krolikowski, Jan; Frueboes, Tomasz; Gokieli, Ryszard; Górski, Maciej; Kazana, Malgorzata; Nawrocki, Krzysztof; Romanowska-Rybinska, Katarzyna; Szleper, Michal; Wrochna, Grzegorz; Zalewski, Piotr; Almeida, Nuno; David Tinoco Mendes, Andre; Faccioli, Pietro; Ferreira Parracho, Pedro Guilherme; Gallinaro, Michele; Sá Martins, Pedro; Musella, Pasquale; Nayak, Aruna; Ribeiro, Pedro Quinaz; Seixas, Joao; Silva, Pedro; Varela, Joao; Wöhri, Hermine Katharina; Belotelov, Ivan; Bunin, Pavel; Finger, Miroslav; Finger Jr., Michael; Golutvin, Igor; Kamenev, Alexey; Karjavin, Vladimir; Kozlov, Guennady; Lanev, Alexander; Moisenz, Petr; Palichik, Vladimir; Perelygin, Victor; Shmatov, Sergey; Smirnov, Vitaly; Volodko, Anton; Zarubin, Anatoli; Bondar, Nikolai; Golovtsov, Victor; Ivanov, Yury; Kim, Victor; Levchenko, Petr; Murzin, Victor; Oreshkin, Vadim; Smirnov, Igor; Sulimov, Valentin; Uvarov, Lev; Vavilov, Sergey; Vorobyev, Alexey; Andreev, Yuri; Gninenko, Sergei; Golubev, Nikolai; Kirsanov, Mikhail; Krasnikov, Nikolai; Matveev, Viktor; Pashenkov, Anatoli; Toropin, Alexander; Troitsky, Sergey; Epshteyn, Vladimir; Gavrilov, Vladimir; Kaftanov, Vitali; Kossov, Mikhail; Krokhotin, Andrey; Lychkovskaya, Natalia; Safronov, Grigory; Semenov, Sergey; Stolin, Viatcheslav; Vlasov, Evgueni; Zhokin, Alexander; Boos, Edouard; Dubinin, Mikhail; Dudko, Lev; Ershov, Alexander; Gribushin, Andrey; Kodolova, Olga; Lokhtin, Igor; Obraztsov, Stepan; Petrushanko, Sergey; Sarycheva, Ludmila; Savrin, Viktor; Snigirev, Alexander; Andreev, Vladimir; Azarkin, Maksim; Dremin, Igor; Kirakosyan, Martin; Rusakov, Sergey V.; Vinogradov, Alexey; Azhgirey, Igor; Bitioukov, Sergei; Grishin, Viatcheslav; Kachanov, Vassili; Konstantinov, Dmitri; Korablev, Andrey; Krychkine, Victor; Petrov, Vladimir; Ryutin, Roman; Slabospitsky, Sergey; Sobol, Andrei; Tourtchanovitch, Leonid; Troshin, Sergey; Tyurin, Nikolay; Uzunian, Andrey; Volkov, Alexey; Adzic, Petar; Djordjevic, Milos; Krpic, Dragomir; Milosevic, Jovan; Aguilar-Benitez, Manuel; Alcaraz Maestre, Juan; Arce, Pedro; Battilana, Carlo; Calvo, Enrique; Cepeda, Maria; Cerrada, Marcos; Colino, Nicanor; De La Cruz, Begona; Diez Pardos, Carmen; Domínguez Vázquez, Daniel; Fernandez Bedoya, Cristina; Fernández Ramos, Juan Pablo; Ferrando, Antonio; Flix, Jose; Fouz, Maria Cruz; Garcia-Abia, Pablo; Gonzalez Lopez, Oscar; Goy Lopez, Silvia; Hernandez, Jose M.; Josa, Maria Isabel; Merino, Gonzalo; Puerta Pelayo, Jesus; Redondo, Ignacio; Romero, Luciano; Santaolalla, Javier; Willmott, Carlos; Albajar, Carmen; Codispoti, Giuseppe; de Trocóniz, Jorge F; Cuevas, Javier; Fernandez Menendez, Javier; Folgueras, Santiago; Gonzalez Caballero, Isidro; Lloret Iglesias, Lara; Vizan Garcia, Jesus Manuel; Brochero Cifuentes, Javier Andres; Cabrillo, Iban Jose; Calderon, Alicia; Chamizo Llatas, Maria; Chuang, Shan-Huei; Duarte Campderros, Jordi; Felcini, Marta; Fernandez, Marcos; Gomez, Gervasio; Gonzalez Sanchez, Javier; Jorda, Clara; Lobelle Pardo, Patricia; Lopez Virto, Amparo; Marco, Jesus; Marco, Rafael; Martinez Rivero, Celso; Matorras, Francisco; Munoz Sanchez, Francisca Javiela; Piedra Gomez, Jonatan; Rodrigo, Teresa; Ruiz Jimeno, Alberto; Scodellaro, Luca; Sobron Sanudo, Mar; Vila, Ivan; Vilar Cortabitarte, Rocio; Abbaneo, Duccio; Auffray, Etiennette; Auzinger, Georg; Baillon, Paul; Ball, Austin; Barney, David; Bell, Alan James; Benedetti, Daniele; Bernet, Colin; Bialas, Wojciech; Bloch, Philippe; Bocci, Andrea; Bolognesi, Sara; Breuker, Horst; Brona, Grzegorz; Bunkowski, Karol; Camporesi, Tiziano; Cano, Eric; Cerminara, Gianluca; Christiansen, Tim; Coarasa Perez, Jose Antonio; Curé, Benoît; D'Enterria, David; De Roeck, Albert; Duarte Ramos, Fernando; Elliott-Peisert, Anna; Frisch, Benjamin; Funk, Wolfgang; Gaddi, Andrea; Gennai, Simone; Georgiou, Georgios; Gerwig, Hubert; Gigi, Dominique; Gill, Karl; Giordano, Domenico; Glege, Frank; Gomez-Reino Garrido, Robert; Gouzevitch, Maxime; Govoni, Pietro; Gowdy, Stephen; Guiducci, Luigi; Hansen, Magnus; Harvey, John; Hegeman, Jeroen; Hegner, Benedikt; Henderson, Conor; Hesketh, Gavin; Hoffmann, Hans Falk; Honma, Alan; Innocente, Vincenzo; Janot, Patrick; Karavakis, Edward; Lecoq, Paul; Leonidopoulos, Christos; Lourenco, Carlos; Macpherson, Alick; Maki, Tuula; Malgeri, Luca; Mannelli, Marcello; Masetti, Lorenzo; Meijers, Frans; Mersi, Stefano; Meschi, Emilio; Moser, Roland; Mozer, Matthias Ulrich; Mulders, Martijn; Nesvold, Erik; Nguyen, Matthew; Orimoto, Toyoko; Orsini, Luciano; Perez, Emmanuelle; Petrilli, Achille; Pfeiffer, Andreas; Pierini, Maurizio; Pimiä, Martti; Polese, Giovanni; Racz, Attila; Rolandi, Gigi; Rommerskirchen, Tanja; Rovelli, Chiara; Rovere, Marco; Sakulin, Hannes; Schäfer, Christoph; Schwick, Christoph; Segoni, Ilaria; Sharma, Archana; Siegrist, Patrice; Simon, Michal; Sphicas, Paraskevas; Spiga, Daniele; Spiropulu, Maria; Stöckli, Fabian; Stoye, Markus; Tropea, Paola; Tsirou, Andromachi; Tsyganov, Andrey; Veres, Gabor Istvan; Vichoudis, Paschalis; Voutilainen, Mikko; Zeuner, Wolfram Dietrich; Bertl, Willi; Deiters, Konrad; Erdmann, Wolfram; Gabathuler, Kurt; Horisberger, Roland; Ingram, Quentin; Kaestli, Hans-Christian; König, Stefan; Kotlinski, Danek; Langenegger, Urs; Meier, Frank; Renker, Dieter; Rohe, Tilman; Sibille, Jennifer; Starodumov, Andrei; Bortignon, Pierluigi; Caminada, Lea; Chen, Zhiling; Cittolin, Sergio; Dissertori, Günther; Dittmar, Michael; Eugster, Jürg; Freudenreich, Klaus; Grab, Christoph; Hervé, Alain; Hintz, Wieland; Lecomte, Pierre; Lustermann, Werner; Marchica, Carmelo; Martinez Ruiz del Arbol, Pablo; Meridiani, Paolo; Milenovic, Predrag; Moortgat, Filip; Nef, Pascal; Nessi-Tedaldi, Francesca; Pape, Luc; Pauss, Felicitas; Punz, Thomas; Rizzi, Andrea; Ronga, Frederic Jean; Rossini, Marco; Sala, Leonardo; Sanchez, Ann - Karin; Sawley, Marie-Christine; Stieger, Benjamin; Tauscher, Ludwig; Thea, Alessandro; Theofilatos, Konstantinos; Treille, Daniel; Urscheler, Christina; Wallny, Rainer; Weber, Matthias; Wehrli, Lukas; Weng, Joanna; Aguiló, Ernest; Amsler, Claude; Chiochia, Vincenzo; De Visscher, Simon; Favaro, Carlotta; Ivova Rikova, Mirena; Millan Mejias, Barbara; Regenfus, Christian; Robmann, Peter; Schmidt, Alexander; Snoek, Hella; Wilke, Lotte; Chang, Yuan-Hann; Chen, Kuan-Hsin; Chen, Wan-Ting; Dutta, Suchandra; Go, Apollo; Kuo, Chia-Ming; Li, Syue-Wei; Lin, Willis; Liu, Ming-Hsiung; Liu, Zong-Kai; Lu, Yun-Ju; Wu, Jing-Han; Yu, Shin-Shan; Bartalini, Paolo; Chang, Paoti; Chang, You-Hao; Chang, Yu-Wei; Chao, Yuan; Chen, Kai-Feng; Hou, George Wei-Shu; Hsiung, Yee; Kao, Kai-Yi; Lei, Yeong-Jyi; Lu, Rong-Shyang; Shiu, Jing-Ge; Tzeng, Yeng-Ming; Wang, Minzu; Adiguzel, Aytul; Bakirci, Mustafa Numan; Cerci, Salim; Dozen, Candan; Dumanoglu, Isa; Eskut, Eda; Girgis, Semiray; Gokbulut, Gul; Guler, Yalcin; Gurpinar, Emine; Hos, Ilknur; Kangal, Evrim Ersin; Karaman, Turker; Kayis Topaksu, Aysel; Nart, Alisah; Onengut, Gulsen; Ozdemir, Kadri; Ozturk, Sertac; Polatoz, Ayse; Sogut, Kenan; Tali, Bayram; Topakli, Huseyin; Uzun, Dilber; Vergili, Latife Nukhet; Vergili, Mehmet; Zorbilmez, Caglar; Akin, Ilina Vasileva; Aliev, Takhmasib; Bilmis, Selcuk; Deniz, Muhammed; Gamsizkan, Halil; Guler, Ali Murat; Ocalan, Kadir; Ozpineci, Altug; Serin, Meltem; Sever, Ramazan; Surat, Ugur Emrah; Yildirim, Eda; Zeyrek, Mehmet; Deliomeroglu, Mehmet; Demir, Durmus; Gülmez, Erhan; Halu, Arda; Isildak, Bora; Kaya, Mithat; Kaya, Ozlem; Ozkorucuklu, Suat; Sonmez, Nasuf; Levchuk, Leonid; Bell, Peter; Bostock, Francis; Brooke, James John; Cheng, Teh Lee; Clement, Emyr; Cussans, David; Frazier, Robert; Goldstein, Joel; Grimes, Mark; Hansen, Maria; Hartley, Dominic; Heath, Greg P.; Heath, Helen F.; Huckvale, Benedickt; Jackson, James; Kreczko, Lukasz; Metson, Simon; Newbold, Dave M.; Nirunpong, Kachanon; Poll, Anthony; Senkin, Sergey; Smith, Vincent J.; Ward, Simon; Basso, Lorenzo; Bell, Ken W.; Belyaev, Alexander; Brew, Christopher; Brown, Robert M.; Camanzi, Barbara; Cockerill, David J.A.; Coughlan, John A.; Harder, Kristian; Harper, Sam; Kennedy, Bruce W.; Olaiya, Emmanuel; Petyt, David; Radburn-Smith, Benjamin Charles; Shepherd-Themistocleous, Claire; Tomalin, Ian R.; Womersley, William John; Worm, Steven; Bainbridge, Robert; Ball, Gordon; Ballin, Jamie; Beuselinck, Raymond; Buchmuller, Oliver; Colling, David; Cripps, Nicholas; Cutajar, Michael; Davies, Gavin; Della Negra, Michel; Fulcher, Jonathan; Futyan, David; Guneratne Bryer, Arlo; Hall, Geoffrey; Hatherell, Zoe; Hays, Jonathan; Iles, Gregory; Karapostoli, Georgia; Lyons, Louis; Magnan, Anne-Marie; Marrouche, Jad; Nandi, Robin; Nash, Jordan; Nikitenko, Alexander; Papageorgiou, Anastasios; Pesaresi, Mark; Petridis, Konstantinos; Pioppi, Michele; Raymond, David Mark; Rompotis, Nikolaos; Rose, Andrew; Ryan, Matthew John; Seez, Christopher; Sharp, Peter; Sparrow, Alex; Tapper, Alexander; Tourneur, Stephane; Vazquez Acosta, Monica; Virdee, Tejinder; Wakefield, Stuart; Wardrope, David; Whyntie, Tom; Barrett, Matthew; Chadwick, Matthew; Cole, Joanne; Hobson, Peter R.; Khan, Akram; Kyberd, Paul; Leslie, Dawn; Martin, William; Reid, Ivan; Teodorescu, Liliana; Hatakeyama, Kenichi; Bose, Tulika; Carrera Jarrin, Edgar; Clough, Andrew; Fantasia, Cory; Heister, Arno; St. John, Jason; Lawson, Philip; Lazic, Dragoslav; Rohlf, James; Sperka, David; Sulak, Lawrence; Avetisyan, Aram; Bhattacharya, Saptaparna; Chou, John Paul; Cutts, David; Ferapontov, Alexey; Heintz, Ulrich; Jabeen, Shabnam; Kukartsev, Gennadiy; Landsberg, Greg; Narain, Meenakshi; Nguyen, Duong; Segala, Michael; Speer, Thomas; Tsang, Ka Vang; Borgia, Maria Assunta; Breedon, Richard; Calderon De La Barca Sanchez, Manuel; Cebra, Daniel; Chauhan, Sushil; Chertok, Maxwell; Conway, John; Cox, Peter Timothy; Dolen, James; Erbacher, Robin; Friis, Evan; Ko, Winston; Kopecky, Alexandra; Lander, Richard; Liu, Haidong; Maruyama, Sho; Miceli, Tia; Nikolic, Milan; Pellett, Dave; Robles, Jorge; Salur, Sevil; Schwarz, Thomas; Searle, Matthew; Smith, John; Squires, Michael; Tripathi, Mani; Vasquez Sierra, Ricardo; Veelken, Christian; Andreev, Valeri; Arisaka, Katsushi; Cline, David; Cousins, Robert; Deisher, Amanda; Duris, Joseph; Erhan, Samim; Farrell, Chris; Hauser, Jay; Ignatenko, Mikhail; Jarvis, Chad; Plager, Charles; Rakness, Gregory; Schlein, Peter; Tucker, Jordan; Valuev, Vyacheslav; Babb, John; Clare, Robert; Ellison, John Anthony; Gary, J William; Giordano, Ferdinando; Hanson, Gail; Jeng, Geng-Yuan; Kao, Shih-Chuan; Liu, Feng; Liu, Hongliang; Luthra, Arun; Nguyen, Harold; Pasztor, Gabriella; Satpathy, Asish; Shen, Benjamin C.; Stringer, Robert; Sturdy, Jared; Sumowidagdo, Suharyo; Wilken, Rachel; Wimpenny, Stephen; Andrews, Warren; Branson, James G.; Cerati, Giuseppe Benedetto; Dusinberre, Elizabeth; Evans, David; Golf, Frank; Holzner, André; Kelley, Ryan; Lebourgeois, Matthew; Letts, James; Mangano, Boris; Muelmenstaedt, Johannes; Padhi, Sanjay; Palmer, Christopher; Petrucciani, Giovanni; Pi, Haifeng; Pieri, Marco; Ranieri, Riccardo; Sani, Matteo; Sharma, Vivek; Simon, Sean; Tu, Yanjun; Vartak, Adish; Würthwein, Frank; Yagil, Avraham; Barge, Derek; Bellan, Riccardo; Campagnari, Claudio; D'Alfonso, Mariarosaria; Danielson, Thomas; Flowers, Kristen; Geffert, Paul; Incandela, Joe; Justus, Christopher; Kalavase, Puneeth; Koay, Sue Ann; Kovalskyi, Dmytro; Krutelyov, Vyacheslav; Lowette, Steven; Mccoll, Nickolas; Pavlunin, Viktor; Rebassoo, Finn; Ribnik, Jacob; Richman, Jeffrey; Rossin, Roberto; Stuart, David; To, Wing; Vlimant, Jean-Roch; Bornheim, Adolf; Bunn, Julian; Chen, Yi; Gataullin, Marat; Kcira, Dorian; Litvine, Vladimir; Ma, Yousi; Mott, Alexander; Newman, Harvey B.; Rogan, Christopher; Timciuc, Vladlen; Traczyk, Piotr; Veverka, Jan; Wilkinson, Richard; Yang, Yong; Zhu, Ren-Yuan; Akgun, Bora; Carroll, Ryan; Ferguson, Thomas; Iiyama, Yutaro; Jang, Dong Wook; Jun, Soon Yung; Liu, Yueh-Feng; Paulini, Manfred; Russ, James; Terentyev, Nikolay; Vogel, Helmut; Vorobiev, Igor; Cumalat, John Perry; Dinardo, Mauro Emanuele; Drell, Brian Robert; Edelmaier, Christopher; Ford, William T.; Heyburn, Bernadette; Luiggi Lopez, Eduardo; Nauenberg, Uriel; Smith, James; Stenson, Kevin; Ulmer, Keith; Wagner, Stephen Robert; Zang, Shi-Lei; Agostino, Lorenzo; Alexander, James; Chatterjee, Avishek; Das, Souvik; Eggert, Nicholas; Fields, Laura Johanna; Gibbons, Lawrence Kent; Heltsley, Brian; Hopkins, Walter; Khukhunaishvili, Aleko; Kreis, Benjamin; Kuznetsov, Valentin; Nicolas Kaufman, Gala; Patterson, Juliet Ritchie; Puigh, Darren; Riley, Daniel; Ryd, Anders; Shi, Xin; Sun, Werner; Teo, Wee Don; Thom, Julia; Thompson, Joshua; Vaughan, Jennifer; Weng, Yao; Winstrom, Lucas; Wittich, Peter; Biselli, Angela; Cirino, Guy; Winn, Dave; Abdullin, Salavat; Albrow, Michael; Anderson, Jacob; Apollinari, Giorgio; Atac, Muzaffer; Bakken, Jon Alan; Banerjee, Sunanda; Bauerdick, Lothar A.T.; Beretvas, Andrew; Berryhill, Jeffrey; Bhat, Pushpalatha C.; Bloch, Ingo; Borcherding, Frederick; Burkett, Kevin; Butler, Joel Nathan; Chetluru, Vasundhara; Cheung, Harry; Chlebana, Frank; Cihangir, Selcuk; Demarteau, Marcel; Eartly, David P.; Elvira, Victor Daniel; Esen, Selda; Fisk, Ian; Freeman, Jim; Gao, Yanyan; Gottschalk, Erik; Green, Dan; Gunthoti, Kranti; Gutsche, Oliver; Hahn, Alan; Hanlon, Jim; Harris, Robert M.; Hirschauer, James; Hooberman, Benjamin; James, Eric; Jensen, Hans; Johnson, Marvin; Joshi, Umesh; Khatiwada, Rakshya; Kilminster, Benjamin; Klima, Boaz; Kousouris, Konstantinos; Kunori, Shuichi; Kwan, Simon; Limon, Peter; Lipton, Ron; Lykken, Joseph; Maeshima, Kaori; Marraffino, John Michael; Mason, David; McBride, Patricia; McCauley, Thomas; Miao, Ting; Mishra, Kalanand; Mrenna, Stephen; Musienko, Yuri; Newman-Holmes, Catherine; O'Dell, Vivian; Popescu, Sorina; Pordes, Ruth; Prokofyev, Oleg; Saoulidou, Niki; Sexton-Kennedy, Elizabeth; Sharma, Seema; Soha, Aron; Spalding, William J.; Spiegel, Leonard; Tan, Ping; Taylor, Lucas; Tkaczyk, Slawek; Uplegger, Lorenzo; Vaandering, Eric Wayne; Vidal, Richard; Whitmore, Juliana; Wu, Weimin; Yang, Fan; Yumiceva, Francisco; Yun, Jae Chul; Acosta, Darin; Avery, Paul; Bourilkov, Dimitri; Chen, Mingshui; Di Giovanni, Gian Piero; Dobur, Didar; Drozdetskiy, Alexey; Field, Richard D.; Fisher, Matthew; Fu, Yu; Furic, Ivan-Kresimir; Gartner, Joseph; Goldberg, Sean; Kim, Bockjoo; Klimenko, Sergey; Konigsberg, Jacobo; Korytov, Andrey; Kropivnitskaya, Anna; Kypreos, Theodore; Matchev, Konstantin; Mitselmakher, Guenakh; Muniz, Lana; Pakhotin, Yuriy; Prescott, Craig; Remington, Ronald; Schmitt, Michael Houston; Scurlock, Bobby; Sellers, Paul; Skhirtladze, Nikoloz; Wang, Dayong; Yelton, John; Zakaria, Mohammed; Ceron, Cristobal; Gaultney, Vanessa; Kramer, Laird; Lebolo, Luis Miguel; Linn, Stephan; Markowitz, Pete; Martinez, German; Rodriguez, Jorge Luis; Adams, Todd; Askew, Andrew; Bandurin, Dmitry; Bochenek, Joseph; Chen, Jie; Diamond, Brendan; Gleyzer, Sergei V; Haas, Jeff; Hagopian, Sharon; Hagopian, Vasken; Jenkins, Merrill; Johnson, Kurtis F.; Prosper, Harrison; Sekmen, Sezen; Veeraraghavan, Venkatesh; Baarmand, Marc M.; Dorney, Brian; Guragain, Samir; Hohlmann, Marcus; Kalakhety, Himali; Ralich, Robert; Vodopiyanov, Igor; Adams, Mark Raymond; Anghel, Ioana Maria; Apanasevich, Leonard; Bai, Yuting; Bazterra, Victor Eduardo; Betts, Russell Richard; Callner, Jeremy; Cavanaugh, Richard; Dragoiu, Cosmin; Garcia-Solis, Edmundo Javier; Gerber, Cecilia Elena; Hofman, David Jonathan; Khalatyan, Samvel; Lacroix, Florent; O'Brien, Christine; Silvestre, Catherine; Smoron, Agata; Strom, Derek; Varelas, Nikos; Akgun, Ugur; Albayrak, Elif Asli; Bilki, Burak; Cankocak, Kerem; Clarida, Warren; Duru, Firdevs; Lae, Chung Khim; McCliment, Edward; Merlo, Jean-Pierre; Mermerkaya, Hamit; Mestvirishvili, Alexi; Moeller, Anthony; Nachtman, Jane; Newsom, Charles Ray; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Ozok, Ferhat; Sen, Sercan; Wetzel, James; Yetkin, Taylan; Yi, Kai; Barnett, Bruce Arnold; Blumenfeld, Barry; Bonato, Alessio; Eskew, Christopher; Fehling, David; Giurgiu, Gavril; Gritsan, Andrei; Guo, Zijin; Hu, Guofan; Maksimovic, Petar; Rappoccio, Salvatore; Swartz, Morris; Tran, Nhan Viet; Whitbeck, Andrew; Baringer, Philip; Bean, Alice; Benelli, Gabriele; Grachov, Oleg; Murray, Michael; Noonan, Daniel; Radicci, Valeria; Sanders, Stephen; Wood, Jeffrey Scott; Zhukova, Victoria; Bolton, Tim; Chakaberia, Irakli; Ivanov, Andrew; Makouski, Mikhail; Maravin, Yurii; Shrestha, Shruti; Svintradze, Irakli; Wan, Zongru; Gronberg, Jeffrey; Lange, David; Wright, Douglas; Baden, Drew; Boutemeur, Madjid; Eno, Sarah Catherine; Ferencek, Dinko; Gomez, Jaime; Hadley, Nicholas John; Kellogg, Richard G.; Kirn, Malina; Lu, Ying; Mignerey, Alice; Rossato, Kenneth; Rumerio, Paolo; Santanastasio, Francesco; Skuja, Andris; Temple, Jeffrey; Tonjes, Marguerite; Tonwar, Suresh C.; Twedt, Elizabeth; Alver, Burak; Bauer, Gerry; Bendavid, Joshua; Busza, Wit; Butz, Erik; Cali, Ivan Amos; Chan, Matthew; Dutta, Valentina; Everaerts, Pieter; Gomez Ceballos, Guillelmo; Goncharov, Maxim; Hahn, Kristan Allan; Harris, Philip; Kim, Yongsun; Klute, Markus; Lee, Yen-Jie; Li, Wei; Loizides, Constantinos; Luckey, Paul David; Ma, Teng; Nahn, Steve; Paus, Christoph; Ralph, Duncan; Roland, Christof; Roland, Gunther; Rudolph, Matthew; Stephans, George; Sumorok, Konstanty; Sung, Kevin; Wenger, Edward Allen; Xie, Si; Yang, Mingming; Yilmaz, Yetkin; Yoon, Sungho; Zanetti, Marco; Cole, Perrie; Cooper, Seth; Cushman, Priscilla; Dahmes, Bryan; De Benedetti, Abraham; Dudero, Phillip Russell; Franzoni, Giovanni; Haupt, Jason; Klapoetke, Kevin; Kubota, Yuichi; Mans, Jeremy; Rekovic, Vladimir; Rusack, Roger; Sasseville, Michael; Singovsky, Alexander; Cremaldi, Lucien Marcus; Godang, Romulus; Kroeger, Rob; Perera, Lalith; Rahmat, Rahmat; Sanders, David A; Summers, Don; Bloom, Kenneth; Bose, Suvadeep; Butt, Jamila; Claes, Daniel R.; Dominguez, Aaron; Eads, Michael; Keller, Jason; Kelly, Tony; Kravchenko, Ilya; Lazo-Flores, Jose; Lundstedt, Carl; Malbouisson, Helena; Malik, Sudhir; Snow, Gregory R.; Baur, Ulrich; Godshalk, Andrew; Iashvili, Ia; Kharchilava, Avto; Kumar, Ashish; Shipkowski, Simon Peter; Smith, Kenneth; Alverson, George; Barberis, Emanuela; Baumgartel, Darin; Boeriu, Oana; Chasco, Matthew; Kaadze, Ketino; Reucroft, Steve; Swain, John; Wood, Darien; Zhang, Jinzhong; Anastassov, Anton; Kubik, Andrew; Odell, Nathaniel; Ofierzynski, Radoslaw Adrian; Pollack, Brian; Pozdnyakov, Andrey; Schmitt, Michael Henry; Stoynev, Stoyan; Velasco, Mayda; Won, Steven; Antonelli, Louis; Berry, Douglas; Hildreth, Michael; Jessop, Colin; Karmgard, Daniel John; Kolb, Jeff; Kolberg, Ted; Lannon, Kevin; Luo, Wuming; Lynch, Sean; Marinelli, Nancy; Morse, David Michael; Pearson, Tessa; Ruchti, Randy; Slaunwhite, Jason; Valls, Nil; Warchol, Jadwiga; Wayne, Mitchell; Ziegler, Jill; Bylsma, Ben; Durkin, Lloyd Stanley; Gu, Jianhui; Hill, Christopher; Killewald, Phillip; Kotov, Khristian; Ling, Ta-Yung; Rodenburg, Marissa; Williams, Grayson; Adam, Nadia; Berry, Edmund; Elmer, Peter; Gerbaudo, Davide; Halyo, Valerie; Hebda, Philip; Hunt, Adam; Jones, John; Laird, Edward; Lopes Pegna, David; Marlow, Daniel; Medvedeva, Tatiana; Mooney, Michael; Olsen, James; Piroué, Pierre; Quan, Xiaohang; Saka, Halil; Stickland, David; Tully, Christopher; Werner, Jeremy Scott; Zuranski, Andrzej; Acosta, Jhon Gabriel; Huang, Xing Tao; Lopez, Angel; Mendez, Hector; Oliveros, Sandra; Ramirez Vargas, Juan Eduardo; Zatserklyaniy, Andriy; Alagoz, Enver; Barnes, Virgil E.; Bolla, Gino; Borrello, Laura; Bortoletto, Daniela; Everett, Adam; Garfinkel, Arthur F.; Gecse, Zoltan; Gutay, Laszlo; Hu, Zhen; Jones, Matthew; Koybasi, Ozhan; Laasanen, Alvin T.; Leonardo, Nuno; Liu, Chang; Maroussov, Vassili; Merkel, Petra; Miller, David Harry; Neumeister, Norbert; Potamianos, Karolos; Shipsey, Ian; Silvers, David; Svyatkovskiy, Alexey; Yoo, Hwi Dong; Zablocki, Jakub; Zheng, Yu; Jindal, Pratima; Parashar, Neeti; Boulahouache, Chaouki; Cuplov, Vesna; Ecklund, Karl Matthew; Geurts, Frank J.M.; Liu, Jinghua H.; Morales, Jafet; Padley, Brian Paul; Redjimi, Radia; Roberts, Jay; Zabel, James; Betchart, Burton; Bodek, Arie; Chung, Yeon Sei; Covarelli, Roberto; de Barbaro, Pawel; Demina, Regina; Eshaq, Yossof; Flacher, Henning; Garcia-Bellido, Aran; Goldenzweig, Pablo; Gotra, Yury; Han, Jiyeon; Harel, Amnon; Miner, Daniel Carl; Orbaker, Douglas; Petrillo, Gianluca; Vishnevskiy, Dmitry; Zielinski, Marek; Bhatti, Anwar; Demortier, Luc; Goulianos, Konstantin; Lungu, Gheorghe; Mesropian, Christina; Yan, Ming; Atramentov, Oleksiy; Barker, Anthony; Duggan, Daniel; Gershtein, Yuri; Gray, Richard; Halkiadakis, Eva; Hidas, Dean; Hits, Dmitry; Lath, Amitabh; Panwalkar, Shruti; Patel, Rishi; Richards, Alan; Rose, Keith; Schnetzer, Steve; Somalwar, Sunil; Stone, Robert; Thomas, Scott; Cerizza, Giordano; Hollingsworth, Matthew; Spanier, Stefan; Yang, Zong-Chang; York, Andrew; Asaadi, Jonathan; Eusebi, Ricardo; Gilmore, Jason; Gurrola, Alfredo; Kamon, Teruki; Khotilovich, Vadim; Montalvo, Roy; Nguyen, Chi Nhan; Osipenkov, Ilya; Pivarski, James; Safonov, Alexei; Sengupta, Sinjini; Tatarinov, Aysen; Toback, David; Weinberger, Michael; Akchurin, Nural; Bardak, Cemile; Damgov, Jordan; Jeong, Chiyoung; Kovitanggoon, Kittikul; Lee, Sung Won; Mane, Poonam; Roh, Youn; Sill, Alan; Volobouev, Igor; Wigmans, Richard; Yazgan, Efe; Appelt, Eric; Brownson, Eric; Engh, Daniel; Florez, Carlos; Gabella, William; Johns, Willard; Kurt, Pelin; Maguire, Charles; Melo, Andrew; Sheldon, Paul; Velkovska, Julia; Arenton, Michael Wayne; Balazs, Michael; Boutle, Sarah; Buehler, Marc; Conetti, Sergio; Cox, Bradley; Francis, Brian; Hirosky, Robert; Ledovskoy, Alexander; Lin, Chuanzhe; Neu, Christopher; Yohay, Rachel; Gollapinni, Sowjanya; Harr, Robert; Karchin, Paul Edmund; Lamichhane, Pramod; Mattson, Mark; Milstène, Caroline; Sakharov, Alexandre; Anderson, Michael; Bachtis, Michail; Bellinger, James Nugent; Carlsmith, Duncan; Dasu, Sridhara; Efron, Jonathan; Gray, Lindsey; Grogg, Kira Suzanne; Grothe, Monika; Hall-Wilton, Richard; Herndon, Matthew; Klabbers, Pamela; Klukas, Jeffrey; Lanaro, Armando; Lazaridis, Christos; Leonard, Jessica; Lomidze, David; Loveless, Richard; Mohapatra, Ajit; Reeder, Don; Ross, Ian; Savin, Alexander; Smith, Wesley H.; Swanson, Joshua; Weinberg, Marc

    2011-01-01

    The result of a search at the LHC for heavy stable charged particles produced in pp collisions at sqrt(s) = 7 TeV is described. The data sample was collected with the CMS detector and corresponds to an integrated luminosity of 3.1 inverse picobarns. Momentum and ionization-energy-loss measurements in the inner tracker detector are used to identify tracks compatible with heavy slow-moving particles. Additionally, tracks passing muon identification requirements are also analyzed for the same signature. In each case, no candidate passes the selection, with an expected background of less than 0.1 events. A lower limit at the 95% confidence level on the mass of a stable gluino is set at 398 GeV/c2, using a conventional model of nuclear interactions that allows charged hadrons containing this particle to reach the muon detectors. A lower limit of 311 GeV/c2 is also set for a stable gluino in a conservative scenario of complete charge suppression, where any hadron containing this particle becomes neutral before rea...

  13. Linear Accelerator Stereotactic Radiosurgery of Central Nervous System Arteriovenous Malformations: A 15-Year Analysis of Outcome-Related Factors in a Single Tertiary Center.

    Science.gov (United States)

    Thenier-Villa, José Luis; Galárraga-Campoverde, Raúl Alejandro; Martínez Rolán, Rosa María; De La Lama Zaragoza, Adolfo Ramón; Martínez Cueto, Pedro; Muñoz Garzón, Víctor; Salgado Fernández, Manuel; Conde Alonso, Cesáreo

    2017-07-01

    Linear accelerator stereotactic radiosurgery is one of the modalities available for the treatment of central nervous system arteriovenous malformations (AVMs). The aim of this study was to describe our 15-year experience with this technique in a single tertiary center and the analysis of outcome-related factors. From 1998 to 2013, 195 patients were treated with linear accelerator-based radiosurgery; we conducted a retrospective study collecting patient- and AVM-related variables. Treatment outcomes were obliteration, posttreatment hemorrhage, symptomatic radiation-induced changes, and 3-year neurologic status. We also analyzed prognostic factors of each outcome and predictability analysis of 5 scales: Spetzler-Martin grade, Lawton-Young supplementary and Lawton combined scores, radiosurgery-based AVM score, Virginia Radiosurgery AVM Scale, and Heidelberg score. Overall obliteration rate was 81%. Nidus diameter and venous drainage were predictive of obliteration (P linear accelerator-based radiosurgery is a useful, valid, effective, and safe modality for treatment of brain AVMs. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Single-centre experience of stereotactic radiosurgery and fractionated stereotactic radiotherapy for prolactinomas with the linear accelerator.

    Science.gov (United States)

    Wilson, Peter J; Williams, Janet Rosemary; Smee, Robert Ian

    2015-06-01

    Primary management of prolactinomas is usually medical, with surgery a secondary option where necessary. This study is a review of a single centre's experience with focused radiotherapy where benefit was not gained by medical or surgical approaches. Radiotherapy as an alternative and adjuvant treatment for prolactinomas has been performed at our institution with the linear accelerator since 1990. We present a retrospective review of 13 patients managed with stereotactic radiosurgery (SRS) and 5 managed with fractionated stereotactic radiotherapy (FSRT), as well as 5 managed with conventional radiotherapy, at the Prince of Wales Hospital. Patients with a histopathologically diagnosed prolactinoma were eligible. Those patients who had a confirmed pathological diagnosis of prolactinoma following surgical intervention, a prolactin level elevated above 500 μg/L, or a prolactin level persistently elevated above 200 μg/L with exclusion of other causes were represented in this review. At the end of documented follow-up (SRS median 6 years, FSRT median 2 years), no SRS patients showed an increase in tumour volume. After FSRT, 1 patient showed an increase in size, 2 showed a decrease in size and 2 patients showed no change. Prolactin levels trended towards improvement after SRS and FSRT, but no patients achieved the remission level of <20 μg/L. Seven of 13 patients in the SRS group achieved a level of <500 μg/L, whereas no patients reached this target after FSRT. A reduction in prolactin level is frequent after SRS and FSRT for prolactinomas; however, true biochemical remission is uncommon. Tumour volume control in this series was excellent, but this may be related to the natural history of the disease. Morbidity and mortality after stereotactic radiation were very low in this series. © 2014 The Royal Australian and New Zealand College of Radiologists.

  15. Role of gamma knife radiosurgery in neurosurgery. Past and future perspectives

    International Nuclear Information System (INIS)

    Koga, Tomoyuki; Shin, Masahiro; Saito, Nobuhito

    2010-01-01

    The gamma knife was the first radiosurgical device developed at the Karolinska Institute in 1967. Stereotactic radiosurgery using the gamma knife has been widely accepted in clinical practice and has contributed to the development of neurosurgery. More than 500,000 patients have been treated by gamma knife stereotactic radiosurgery so far, and the method is now an indispensable neurosurgical tool. Here we review long-term outcomes and development of stereotactic radiosurgery using the gamma knife and discuss its future perspectives. The primary role of stereotactic radiosurgery is to control small well-demarcated lesions such as metastatic brain tumors, meningiomas, schwannomas, and pituitary adenomas while preserving the function of surrounding brain tissue. The gamma knife has been used as a primary treatment or in combination with surgery, and some applications have been accepted as standard treatment in the field of neurosurgery. Treatment of cerebral arteriovenous malformations has also been drastically changed after emergence of this technology. Controlling functional disorders is another role of stereotactic radiosurgery. There is a risk of radiation-induced adverse events, which are usually mild and less frequent. However, especially in large or invasive lesions, those risks are not negligible and pose limitations. Advancement of irradiation technology and dose planning software have enabled more sophisticated and safer treatment, and further progress will contribute to better treatment outcomes not only for brain lesions but also for cervical lesions with less invasive treatment. (author)

  16. Comparison of static conformal field with multiple noncoplanar arc techniques for stereotactic radiosurgery or stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Hamilton, Russell J.; Kuchnir, Franca T.; Sweeney, Patrick; Rubin, Steven J.; Dujovny, Manuel; Pelizzari, Charles A.; Chen, George T. Y.

    1995-01-01

    Purpose: Compare the use of static conformal fields with the use of multiple noncoplanar arcs for stereotactic radiosurgery or stereotactic radiotherapy treatment of intracranial lesions. Evaluate the efficacy of these treatment techniques to deliver dose distributions comparable to those considered acceptable in current radiotherapy practice. Methods and Materials: A previously treated radiosurgery case of a patient presenting with an irregularly shaped intracranial lesion was selected. Using a three-dimensional (3D) treatment-planning system, treatment plans using a single isocenter multiple noncoplanar arc technique and multiple noncoplanar conformal static fields were generated. Isodose distributions and dose volume histograms (DVHs) were computed for each treatment plan. We required that the 80% (of maximum dose) isodose surface enclose the target volume for all treatment plans. The prescription isodose was set equal to the minimum target isodose. The DVHs were analyzed to evaluate and compare the different treatment plans. Results: The dose distribution in the target volume becomes more uniform as the number of conformal fields increases. The volume of normal tissue receiving low doses (> 10% of prescription isodose) increases as the number of static fields increases. The single isocenter multiple arc plan treats the greatest volume of normal tissue to low doses, approximately 1.6 times more volume than that treated by four static fields. The volume of normal tissue receiving high (> 90% of prescription isodose) and intermediate (> 50% of prescription isodose) doses decreases by 29 and 22%, respectively, as the number of static fields is increased from four to eight. Increasing the number of static fields to 12 only further reduces the high and intermediate dose volumes by 10 and 6%, respectively. The volume receiving the prescription dose is more than 3.5 times larger than the target volume for all treatment plans. Conclusions: Use of a multiple noncoplanar

  17. Cataractogenic effects of heavy charged particles in mice

    International Nuclear Information System (INIS)

    Ainsworth, E.J.; Jose, J.G.; Yang, V.V.; Barker, M.E.

    1980-01-01

    The effects of heavy charged particles on the crystalline lens of the eye of mice are important because this tissue has proven susceptible to other forms of high-LET radiation. This report summarizes the results currently available from a prospectively designed study to explore the LET dependence of the cataractogenic process. The present results are consistent with a high cataractogenic effect at 100 keV/μm, because plateau argon 40 ions, with an LET in this range, produce higher average cataracts scores at 9, 11 and 13 months than do carbon 12 or neon 20 ions. In the electron micrographs, significant changes were observed from the controls

  18. Stereotactic Radiosurgery - Gamma Knife

    Science.gov (United States)

    ... DE, Adler JR Jr, Ewend MG. Image-guided robotic radiosurgery. In: Winn RH, ed. Youmans Neurological Surgery . ... by URAC, also known as the American Accreditation HealthCare Commission (www.urac.org). URAC's accreditation program is ...

  19. Role of Adjuvant Radiosurgery after Thoracoscopic Microsurgical Resection of a Spinal Schwannoma

    Directory of Open Access Journals (Sweden)

    Toba N. Niazi

    2012-01-01

    Full Text Available Stereotactic radiosurgery to benign tumors of the spine has not been advocated as a primary treatment modality because of the favorable prognosis for these lesions after gross-total resection. There is even less evidence regarding its use as an adjuvant to neurosurgical resection of benign recurrent spinal disease. We describe the case of a 30-year-old man with a thoracic spinal schwannoma who had an interval increase of his lesion five months after thoracoscopic microsurgical resection. The patient opted for noninvasive stereotactic radiosurgery in lieu of additional surgical excision and has had stable disease 15 months after radiosurgical treatment with the linear accelerator (LINAC system. In this setting, stereotactic radiosurgery provided a useful adjunct to thoracoscopic microsurgical resection. Future Class I and II evidence should be sought to evaluate the utility of stereotactic radiosurgery as a primary treatment modality or as an adjuvant for microneurosurgical resection of benign spinal lesions in patients who want noninvasive treatment after disease recurrence or who harbor medical comorbidities that would preclude them from being safe surgical candidates.

  20. Use of 3.0-T MRI for Stereotactic Radiosurgery Planning for Treatment of Brain Metastases: A Single-Institution Retrospective Review

    International Nuclear Information System (INIS)

    Saconn, Paul A.; Shaw, Edward G.; Chan, Michael D.; Squire, Sarah E.; Johnson, Annette J.; McMullen, Kevin P.; Tatter, Stephen B.; Ellis, Thomas L.; Lovato, James; Bourland, J. Daniel; Ekstrand, Kenneth E.; DeGuzman, Allan F.; Munley, Michael T.

    2010-01-01

    Purpose: To investigate the efficacy of 3.0-T magnetic resonance imaging (MRI) for detecting brain metastases for stereotactic radiosurgery (SRS) planning. Methods and Materials: All adult patients scheduled for SRS treatment for brain metastases at our institution between October 2005 and January 2008 were eligible for analysis. All patients underwent radiosurgery treatment planning 3.0-T MRI on the day of scheduled radiosurgery and a diagnostic 1.5-T MRI in the days or weeks prior to radiosurgery for comparison. Both scans were interpreted by neuroradiologists who reported their findings in the radiology reports. We performed a retrospective review of the radiology reports to determine the number of brain metastases identified using each MRI system. Results: Of 254 patients scheduled for treatment from October 2005 to January 2008, 138 patients had radiology reports that explicitly described the number of metastases identified on both scans. With a median interval of 17 days (range, 1-82) between scans, the number of metastases detected using 1.5-T MRI system ranged from 1 to 5 and from 1 to 8 using the 3.0 T-MRI system. Twenty-two percent of patients were found to have a greater number of metastases with the 3.0 T-MRI system. The difference in number of metastases detected between the two scans for the entire cohort ranged from 0 to 6. Neither histology (p = 0.52 by chi-sq test) nor time between scans (p = 0.62 by linear regression) were significantly associated with the difference in number of metastases between scans. Conclusions: The 3.0-T MRI system appears to be superior to a 1.5-T MRI system for detecting brain metastases, which may have significant implications in determining the appropriate treatment modality. Our findings suggest the need for a prospectively designed study to further evaluate the use of a 3.0 T-MRI system for stereotactic radiosurgery planning in the treatment of brain metastases.

  1. Development of a phantom for quality control of radiosurgery

    International Nuclear Information System (INIS)

    Scheidegger Soboll, D.; Reuters Schelin, H.

    2008-01-01

    The aim of this work was to build a phantom for quality control of stereotactic radiosurgery on linear accelerators. The outward appearance is a translucent human head filled with water and enclosing an insert with test objects of known shapes. The phantom was submitted to computerized tomography, magnetic resonance imaging and angiography exams, in order to perform a radiosurgery planning. Contours of the internal structures on the therapy planning system were drawn over the MRI images. Through the image fusion of CT and MRI, the contour data was transferred to CT images. Stereotactic registration of CT and angiography was made. One isocenter treatment was created, and using the stereotactic coordinates given by the therapy planning system, the phantom was placed on a linac. X-ray images were performed in order to verify the final positioning of the planned isocenter. In the whole process the phantom showed usefulness and adequacy for the positioning quality control of stereotactic radiosurgery with linacs, according to the main documents concerning the issue. (author)

  2. Clinical accuracy of ExacTrac intracranial frameless stereotactic system

    International Nuclear Information System (INIS)

    Ackerly, T.; Lancaster, C. M.; Geso, M.; Roxby, K. J.

    2011-01-01

    Purpose: In this paper, the authors assess the accuracy of the Brainlab ExacTrac system for frameless intracranial stereotactic treatments in clinical practice. Methods: They recorded couch angle and image fusion results (comprising lateral, longitudinal, and vertical shifts, and rotation corrections about these axes) for 109 stereotactic radiosurgery and 166 stereotactic radiotherapy patient treatments. Frameless stereotactic treatments involve iterative 6D image fusion corrections applied until the results conform to customizable pass criteria, theirs being 0.7 mm and 0.5 deg. for each axis. The planning CT slice thickness was 1.25 mm. It has been reported in the literature that the CT slices' thickness impacts the accuracy of localization to bony anatomy. The principle of invariance with respect to patient orientation was used to determine spatial accuracy. Results: The data for radiosurgery comprised 927 image pairs, of which 532 passed (pass ratio of 57.4%). The data for radiotherapy comprised 15983 image pairs, of which 10 050 passed (pass ratio of 62.9%). For stereotactic radiotherapy, the combined uncertainty of ExacTrac calibration, image fusion, and intrafraction motion was (95% confidence interval) 0.290-0.302 and 0.306-0.319 mm in the longitudinal and lateral axes, respectively. The combined uncertainty of image fusion and intrafraction motion in the anterior-posterior coordinates was 0.174-0.182 mm. For stereotactic radiosurgery, the equivalent ranges are 0.323-0.393, 0.337-0.409, and 0.231-0.281 mm. The overall spatial accuracy was 1.24 mm for stereotactic radiotherapy (SRT) and 1.35 mm for stereotactic radiosurgery (SRS). Conclusions: The ExacTrac intracranial frameless stereotactic system spatial accuracy is adequate for clinical practice, and with the same pass criteria, SRT is more accurate than SRS. They now use frameless stereotaxy exclusively at their center.

  3. Optimal technique of linear accelerator-based stereotactic radiosurgery for tumors adjacent to brainstem.

    Science.gov (United States)

    Chang, Chiou-Shiung; Hwang, Jing-Min; Tai, Po-An; Chang, You-Kang; Wang, Yu-Nong; Shih, Rompin; Chuang, Keh-Shih

    2016-01-01

    Stereotactic radiosurgery (SRS) is a well-established technique that is replacing whole-brain irradiation in the treatment of intracranial lesions, which leads to better preservation of brain functions, and therefore a better quality of life for the patient. There are several available forms of linear accelerator (LINAC)-based SRS, and the goal of the present study is to identify which of these techniques is best (as evaluated by dosimetric outcomes statistically) when the target is located adjacent to brainstem. We collected the records of 17 patients with lesions close to the brainstem who had previously been treated with single-fraction radiosurgery. In all, 5 different lesion catalogs were collected, and the patients were divided into 2 distance groups-1 consisting of 7 patients with a target-to-brainstem distance of less than 0.5cm, and the other of 10 patients with a target-to-brainstem distance of ≥ 0.5 and linear accelerator is only 1 modality can to establish for SRS treatment. Based on statistical evidence retrospectively, we recommend VMAT as the optimal technique for delivering treatment to tumors adjacent to brainstem. Copyright © 2016 American Association of Medical Dosimetrists. All rights reserved.

  4. Stereotactic Radiosurgery for Classical Trigeminal Neuralgia

    Directory of Open Access Journals (Sweden)

    Henry Kodrat

    2016-04-01

    Full Text Available Trigeminal neuralgia is a debilitating pain syndrome with a distinct symptom mainly excruciating facial pain that tends to come and go unpredictably in sudden shock-like attacks. Medical management remains the primary treatment for classical trigeminal neuralgia. When medical therapy failed, surgery with microvascular decompression can be performed. Radiosurgery can be offered for classical trigeminal neuralgia patients who are not surgical candidate or surgery refusal and they should not in acute pain condition. Radiosurgery is widely used because of good therapeutic result and low complication rate. Weakness of this technique is a latency period, which is time required for pain relief. It usually ranges from 1 to 2 months. This review enlightens the important role of radiosurgery in the treatment of classical trigeminal neuralgia.

  5. Charges collection induced in APS by heavy particles: influence of design parameters

    International Nuclear Information System (INIS)

    Belredon, Xavier

    2003-01-01

    We have studied the design parameters influence on heavy ions-induced charge collection physics in APS. The goal is to determine the key parameters for an optimised space environment 'particle detector' APS design. It appears that diffusion is the dominant charge collection mechanism in all the studied technology types, with a smaller magnitude in case of epitaxial technologies. Following proton irradiation, a delayed charge collection and loss of collected charges have been observed. These phenomena are explained by the combination of carriers diffusion and action of the traps generated in the device. Even if they cannot be avoid in space applications, these effects are reduced in case of epitaxial technologies. This work led to the design parameters definition of an optimized APS 'particle detector' and to its fabrication. The results obtained on this APS confirm the previous conclusions and let us define the detection range of such detectors from 0.03 to 50 MeV.cm 2 .mg -1 . (author) [fr

  6. Stereotactic radiosurgery in acoustic neurinomas

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Masaaki; Noren, G. (Karolinska Hospital, Stockholm (Sweden))

    1990-12-01

    The records of 57 patients with 61 acoustic neurinomas treated with stereotatic radiosurgery at the Karolinska Hospital, Stockholm, from 1982 through 1984, were reviewed. Adequate radiological and clinical follow-up evaluations were available in these cases. An additional 8 patients were treated during this same period but were not included because of insufficient data. The tumors were evaluated with CT or MRI. Their post-operative follow-up period was 6-66 months (mean 28 months). Decrease of tumor size or no change was considered as a response to radiosurgery. This was found in 54 (88%) of the tumors. Small tumors with a diameter of less than 15 mm responded better (93%) than large ones (85%). Ninety-five percent of unilateral tumors and 74% of tumors associated with neurofibromatosis responded well. Seven tumors had definite radiographic signs of subsequent growth. Four were removed using standard microsurgical tequniques and three have so far not required further treatment. Facial and trigeminal nerve function was evaluated in 58 facial surfaces where tumors had been irradiated. Transient facial weakness developed in 9% and facial hypesthesia in 9% of the irradiated cases. The onset of these nerve dysfunction appeared with a latency period of 4 to 15 months after radiosurgery. Excluding the ears which had been totally deaf before the treatment, forty-one ears were evaluated fully by audiometry prior to and one year after irradiation. 30% of them had no change in hearing, 68% had a more or less pronouced deterioration and 2% had improvement. We regard efficiency in arresting tumor growth without endangering life, preservation of facial nerve function, and only a day of hospitalization as major benefits of radiosurgery. (author).

  7. Re-irradiation of recurrent anaplastic ependymoma using radiosurgery or fractionated stereotactic radiotherapy.

    Science.gov (United States)

    Murai, Taro; Sato, Kengo; Iwabuchi, Michio; Manabe, Yoshihiko; Ogino, Hiroyuki; Iwata, Hiromitsu; Tatewaki, Koshi; Yokota, Naoki; Ohta, Seiji; Shibamoto, Yuta

    2016-03-01

    Recurrent ependymomas were retreated with stereotactic radiosurgery (SRS) or fractionated stereotactic radiotherapy (FSRT). The efficacy, toxicities, and differences between SRS and FSRT were analyzed. Eight patients with recurrent ependymomas fulfilling the criteria described below were evaluated. Inclusion criteria were: (1) the patient had previously undergone surgery and conventional radiotherapy as first-line treatment; (2) targets were located in or adjacent to the eloquent area or were deep-seated; and (3) the previously irradiated volume overlapped the target lesion. FSRT was delivered to 18 lesions, SRS to 20 lesions. A median follow-up period was 23 months. The local control rate was 76 % at 3 years. No significant differences in local control were observed due to tumor size or fractionation schedule. Lesions receiving >25 Gy/5 fr or 21 Gy/3 fr did not recur within 1 year, whereas no dose-response relationship was observed in those treated with SRS. No grade ≥2 toxicity was observed. Our treatment protocol provided an acceptable LC rate and minimal toxicities. Because local recurrence of tumors may result in patient death, a minimum dose of 21 Gy/3 fr or 25 Gy/5 fr or higher may be most suitable for treatment of these cases.

  8. Stereotactic radiosurgery for newly diagnosed brain metastases. Comparison of three dose levels

    International Nuclear Information System (INIS)

    Rades, Dirk; Hornung, Dagmar; Blanck, Oliver; Martens, Kristina; Khoa, Mai Trong; Trang, Ngo Thuy; Hueppe, Michael; Terheyden, Patrick; Gliemroth, Jan; Schild, Steven E.

    2014-01-01

    Three doses were compared for local control of irradiated metastases, freedom from new brain metastases, and survival in patients receiving stereotactic radiosurgery (SRS) alone for one to three newly diagnosed brain metastases. In all, 134 patients were assigned to three groups according to the SRS dose given to the margins of the lesions: 13-16 Gy (n = 33), 18 Gy (n = 18), and 20 Gy (n = 83). Additional potential prognostic factors were evaluated: age (≤ 60 vs. > 60 years), gender, Karnofsky Performance Scale score (70-80 vs. 90-100), tumor type (non-small-cell lung cancer vs. melanoma vs. others), number of brain metastases (1 vs. 2-3), lesion size ( 24 months). For 13-16 Gy, 18 Gy, and 20 Gy, the 1-year local control rates were 31, 65, and 79 %, respectively (p [de

  9. Radiosurgery by Leksell gamma knife

    International Nuclear Information System (INIS)

    Novotny, Josef

    2008-01-01

    The learning objectives of the lecture were as follows: to learn basic principles of Leksell gamma knife (LGK) radiosurgery; to discuss imaging, treatment planning and optimization procedures; to discuss quality assurance for LGK treatments; and to present examples of diagnoses treated by LGK. The following topics were discussed: Radiosurgery - definition, components of selectivity, fundamentals; Leksell gamma knife - principles; Stereotactic target localization; Radiosurgery - imaging; Treatment planning; LGK treatment; Quality control - process tree, LGK, distortion of scanners, 3D phantom measurements; Physical and technical parameters; and Clinical applications. (P.A.)

  10. Accuracy of target localisation and alignment in stereotactic radiosurgery at Royal Prince Alfred Hospital

    International Nuclear Information System (INIS)

    Downes, S.

    1996-01-01

    Full text: Over the last 30 years, stereotactic radiosurgery has become an effective clinical tool in the treatment of intra-cranial lesions. The use of high doses to a specific target volume in a single fraction and the proximity of critical organs requires very accurate geometric localisation of the various cranial structures (using CT, MRI and angiography imaging) and accurate alignment of the target volume prior to treatment. The purpose of this paper was to determine the accuracy of localising cranial structures using computed tomography and angiographic imaging modalities and to determine the accuracy of aligning the treatment isocentre to the specified coordinates. The sum of these two errors will give the total deviation of the treated target from the actual target. Measurements were made using an anthropomorphic (ART) phantom of an adult male and a cerrobend target. The ART phantom was immobilised using the Brown-Roberts-Wells (BRW) ring. The cerrobend target was inserted into the skull at 10 different positions. Each of these 10 positions were scanned using CT and angiographic imaging and localised using the stereotactic planning software. For each test position, the ART phantom was placed on the treatment couch and aligned to the treatment coordinates determined using localisation (CT and angiography). A-P and lateral port films were then made of the target. The distance between the centre of the cerrobend target (intended target) and the centre of radiation (actual target) was the total error in localisation and alignment of the target. For computed tomography, the measurements showed the average error in localisation and alignment of the target was ±0.7mm. In terms of coordinate axis, the average error was: A-P axis = ±0.5mm, Lateral(left-right) Axis = ±0.3mm, Vertical(inferior superior) Axis ±0.4mm. From these measurements it was shown that using the stereotactic radiosurgery planning system and hardware, cranial lesions could be localised and

  11. SU-F-P-05: Initial Experience with an Independent Certification Program for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Solberg, T; Robar, J; Gevaert, T; Todorovic, M; Howe, J

    2016-01-01

    Purpose: The ASTRO document “Safety is no accident: A FRAMEWORK FOR QUALITY RADIATION ONCOLOGY AND CARE” recommends external reviews of specialized modalities. The purpose of this presentation is to describe the implementation of such a program for Stereotactic Radiosurgery (SRS) and Stereotactic Body radiation Therapy (SBRT). Methods: The margin of error for SRS and SBRT delivery is significantly smaller than that of conventional radiotherapy and therefore requires special attention and diligence. The Novalis Certified program was created to fill an unmet need for specialized SRS / SBRT credentialing. A standards document was drafted by a panel of experts from several disciplines, including medical physics, radiation oncology and neurosurgery. The document, based on national and international standards, covers requirements in program structure, personnel, training, clinical application, technology, quality management, and patient and equipment QA. The credentialing process was modeled after existing certification programs and includes an institution-generated self-study, extensive document review and an onsite audit. Reviewers generate a descriptive report, which is reviewed by a multidisciplinary expert panel. Outcomes of the review may include mandatory requirements and optional recommendations. Results: 15 institutions have received Novalis Certification, including 3 in the US, 7 in Europe, 4 in Australia and 1 in Asia. 87 other centers are at various stages of the process. Nine reviews have resulted in mandatory requirements, however all of these were addressed within three months of the audit report. All reviews have produced specific recommendations ranging from programmatic to technical in nature. Institutions felt that the credentialing process addressed a critical need and was highly valuable to the institution. Conclusion: Novalis Certification is a unique peer review program assessing safety and quality in SRS and SBRT, while recognizing

  12. SU-F-P-05: Initial Experience with an Independent Certification Program for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Solberg, T [University of Pennsylvania, Philadelphia, PA (United States); Robar, J [Capital District Health Authority, Halifax, NS (Canada); Gevaert, T [University Hospital Brussels, Brussels (Belgium); Todorovic, M [Universitats-Klinikum Hamburg-Eppendorf, Hamburg (Germany); Howe, J [Associates In Medical Physics, Louisville, KY (United States)

    2016-06-15

    Purpose: The ASTRO document “Safety is no accident: A FRAMEWORK FOR QUALITY RADIATION ONCOLOGY AND CARE” recommends external reviews of specialized modalities. The purpose of this presentation is to describe the implementation of such a program for Stereotactic Radiosurgery (SRS) and Stereotactic Body radiation Therapy (SBRT). Methods: The margin of error for SRS and SBRT delivery is significantly smaller than that of conventional radiotherapy and therefore requires special attention and diligence. The Novalis Certified program was created to fill an unmet need for specialized SRS / SBRT credentialing. A standards document was drafted by a panel of experts from several disciplines, including medical physics, radiation oncology and neurosurgery. The document, based on national and international standards, covers requirements in program structure, personnel, training, clinical application, technology, quality management, and patient and equipment QA. The credentialing process was modeled after existing certification programs and includes an institution-generated self-study, extensive document review and an onsite audit. Reviewers generate a descriptive report, which is reviewed by a multidisciplinary expert panel. Outcomes of the review may include mandatory requirements and optional recommendations. Results: 15 institutions have received Novalis Certification, including 3 in the US, 7 in Europe, 4 in Australia and 1 in Asia. 87 other centers are at various stages of the process. Nine reviews have resulted in mandatory requirements, however all of these were addressed within three months of the audit report. All reviews have produced specific recommendations ranging from programmatic to technical in nature. Institutions felt that the credentialing process addressed a critical need and was highly valuable to the institution. Conclusion: Novalis Certification is a unique peer review program assessing safety and quality in SRS and SBRT, while recognizing

  13. Heavy Particle Beams in Tumor Radiotherapy

    International Nuclear Information System (INIS)

    Ayad, M.

    1999-01-01

    Using heavy particles beam in the tumor radiotherapy is advantageous to the conventional radiation with photons and electrons. One of the advantages of the heavy charged particle is the energy deposition processes which give a well defined range in tissue, a Bragg peak of ionization in the depth-dose distribution and slow scattering, while the dose to the surrounding healthy tissue in the vicinity is minimized. These processes can show the relation between the heavy particle and the conventional radiation is illustrated with respect to the depth dose and the relative dose. The usage of neutrons (Thermal or epithermal) in therapy necessitates implementation of capture material leading to the production of heavy charged particles (a-particles) as a result of the nuclear interaction in between. Experimentally it is found that 80% of the absorbed dose is mainly due to the presence of capture material

  14. Characteristics of a novel treatment system for linear accelerator-based stereotactic radiosurgery.

    Science.gov (United States)

    Wen, Ning; Li, Haisen; Song, Kwang; Chin-Snyder, Karen; Qin, Yujiao; Kim, Jinkoo; Bellon, Maria; Gulam, Misbah; Gardner, Stephen; Doemer, Anthony; Devpura, Suneetha; Gordon, James; Chetty, Indrin; Siddiqui, Farzan; Ajlouni, Munther; Pompa, Robert; Hammoud, Zane; Simoff, Michael; Kalkanis, Steven; Movsas, Benjamin; Siddiqui, M Salim

    2015-07-08

    The purpose of this study is to characterize the dosimetric properties and accuracy of a novel treatment platform (Edge radiosurgery system) for localizing and treating patients with frameless, image-guided stereotactic radiosurgery (SRS) and stereotactic body radiotherapy (SBRT). Initial measurements of various components of the system, such as a comprehensive assessment of the dosimetric properties of the flattening filter-free (FFF) beams for both high definition (HD120) MLC and conical cone-based treatment, positioning accuracy and beam attenuation of a six degree of freedom (6DoF) couch, treatment head leakage test, and integrated end-to-end accuracy tests, have been performed. The end-to-end test of the system was performed by CT imaging a phantom and registering hidden targets on the treatment couch to determine the localization accuracy of the optical surface monitoring system (OSMS), cone-beam CT (CBCT), and MV imaging systems, as well as the radiation isocenter targeting accuracy. The deviations between the percent depth-dose curves acquired on the new linac-based system (Edge), and the previously published machine with FFF beams (TrueBeam) beyond D(max) were within 1.0% for both energies. The maximum deviation of output factors between the Edge and TrueBeam was 1.6%. The optimized dosimetric leaf gap values, which were fitted using Eclipse dose calculations and measurements based on representative spine radiosurgery plans, were 0.700 mm and 1.000 mm, respectively. For the conical cones, 6X FFF has sharper penumbra ranging from 1.2-1.8 mm (80%-20%) and 1.9-3.8 mm (90%-10%) relative to 10X FFF, which has 1.2-2.2mm and 2.3-5.1mm, respectively. The relative attenuation measurements of the couch for PA, PA (rails-in), oblique, oblique (rails-out), oblique (rails-in) were: -2.0%, -2.5%, -15.6%, -2.5%, -5.0% for 6X FFF and -1.4%, -1.5%, -12.2%, -2.5%, -5.0% for 10X FFF, respectively, with a slight decrease in attenuation versus field size. The systematic

  15. [Transient enlargement of craniopharyngioma cysts after stereotactic radiotherapy and radiosurgery].

    Science.gov (United States)

    Mazerkina, N A; Savateev, A N; Gorelyshev, S K; Konovalov, A N; Trunin, Yu Yu; Golanov, A V; Medvedeva, O A; Kalinin, P L; Kutin, M A; Astafieva, L I; Krasnova, T S; Ozerova, V I; Serova, N K; Butenko, E I; Strunina, Yu V

    Stereotactic radiotherapy/radiosurgery (RT/ES) is an effective technique for treating craniopharyngiomas (CPs). However, enlargement of the cystic part of the tumor occurs in some cases after irradiation. The enlargement may be transient and not require treatment or be a true relapse requiring treatment. In this study, we performed a retrospective analysis of 79 pediatric patients who underwent stereotactic RT or RS after resection of craniopharyngioma. Five-year relapse-free survival after complex treatment of CP was 86%. In the early period after irradiation, 3.5 months (2.7-9.4) on average, enlargement of the cystic component of the tumor was detected in 10 (12.7%) patients; in 9 (11.4%) of them, the enlargement was transient and did not require treatment; in one case, the patient underwent surgery due to reduced visual acuity. In 8 (10.1%) patients, an increase in the residual tumor (a solid component of the tumor in 2 cases and a cystic component of the tumor in 6 cases) occurred in the long-term period after irradiation - after 26.3 months (16.6-48.9) and did not decrease during follow-up in none of the cases, i.e. continued growth of the tumor was diagnosed. A statistical analysis revealed that differences in the terms of transient enlargement and true continued growth were statistically significant (pcraniopharyngioma cyst in the early period (up to 1 year) after RT/RS is usually transient and does not require surgical treatment (except cases where worsening of neurological symptoms occurs, or occlusive hydrocephalus develops).

  16. Search for Heavy Stable Charged Particles at $\\sqrt{s}$ = 13 TeV Utilizing a Multivariate Approach

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00375809

    Heavy stable charged particles (HSCPs) have been searched for at the Large Hadron Collider since its initial data taking in 2010. The search for heavy stable charged particles provide a means of directly probing the new physics realm, as they produce a detector signature unlike any particle discovered to date. The goal of this research is to investigate an idea that was introduced in the later stages of 2010-2012 data taking period. Rather than utilizing the current tight selection on the calculated particle mass the hypothesis is that by incorporating a multivariate approach, specif- ically an artificial neural network, the remaining selection criteria could be loosened allowing for a greater signal acceptance while maintaining acceptable background rejection via the multivariate discriminator from the artificial neural network. The increase in signal acceptance and retention or increase in background rejection increases the discovery potential for HSCPs and as a secondary objective calculates improved limit...

  17. Radiosurgery and the double logistic product formula

    International Nuclear Information System (INIS)

    Flickinger, J.C.; Steiner, L.

    1990-01-01

    The double logistic product formula is proposed as a method for predicting the probability of developing brain necrosis after high dose irradiation of small target volumes as used in stereotactic radiosurgery. Dose-response data observed for the production of localized radiation necreosis for treating intractable pain with the original Leksell gamma unit were used to choose the best fitting parameters for the double logistic product formula. This model can be used with either exponential or linear quadratic formulas to account for the effects of dose, fractionation and time in addition to volume. Dose-response predictions for stereotactic radiosurgery with different sized collimators are presented. (author). 41 refs.; 5 figs.; 1 tab

  18. Search for long-lived heavy charged particles using a ring imaging Cherenkov technique at LHCb

    CERN Document Server

    Aaij, Roel; Adinolfi, Marco; Affolder, Anthony; Ajaltouni, Ziad; Akar, Simon; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio Augusto; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; An, Liupan; Anderlini, Lucio; Anderson, Jonathan; Andreotti, Mirco; Andrews, Jason; Appleby, Robert; Aquines Gutierrez, Osvaldo; Archilli, Flavio; d'Argent, Philippe; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Bachmann, Sebastian; Back, John; Badalov, Alexey; Baesso, Clarissa; Baldini, Wander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Batozskaya, Varvara; Battista, Vincenzo; Bay, Aurelio; Beaucourt, Leo; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Bel, Lennaert; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Benton, Jack; Berezhnoy, Alexander; Bernet, Roland; Bertolin, Alessandro; Bettler, Marc-Olivier; van Beuzekom, Martinus; Bien, Alexander; Bifani, Simone; Bird, Thomas; Birnkraut, Alex; Bizzeti, Andrea; Blake, Thomas; Blanc, Frédéric; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Borghi, Silvia; Borgia, Alessandra; Borsato, Martino; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Brett, David; Britsch, Markward; Britton, Thomas; Brodzicka, Jolanta; Brook, Nicholas; Bursche, Albert; Buytaert, Jan; Cadeddu, Sandro; Calabrese, Roberto; Calvi, Marta; Calvo Gomez, Miriam; Campana, Pierluigi; Campora Perez, Daniel; Capriotti, Lorenzo; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carniti, Paolo; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casanova Mohr, Raimon; Casse, Gianluigi; Cassina, Lorenzo; Castillo Garcia, Lucia; Cattaneo, Marco; Cauet, Christophe; Cavallero, Giovanni; Cenci, Riccardo; Charles, Matthew; Charpentier, Philippe; Chefdeville, Maximilien; Chen, Shanzhen; Cheung, Shu-Faye; Chiapolini, Nicola; Chrzaszcz, Marcin; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coco, Victor; Cogan, Julien; Cogneras, Eric; Cogoni, Violetta; Cojocariu, Lucian; Collazuol, Gianmaria; Collins, Paula; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coombes, Matthew; Coquereau, Samuel; Corti, Gloria; Corvo, Marco; Counts, Ian; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Crocombe, Andrew; Cruz Torres, Melissa Maria; Cunliffe, Samuel; Currie, Robert; D'Ambrosio, Carmelo; Dalseno, Jeremy; David, Pieter; Davis, Adam; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Silva, Weeraddana; De Simone, Patrizia; Dean, Cameron Thomas; Decamp, Daniel; Deckenhoff, Mirko; Del Buono, Luigi; Déléage, Nicolas; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Dey, Biplab; Di Canto, Angelo; Di Ruscio, Francesco; Dijkstra, Hans; Donleavy, Stephanie; Dordei, Francesca; Dorigo, Mirco; Dosil Suárez, Alvaro; Dossett, David; Dovbnya, Anatoliy; Dreimanis, Karlis; Dujany, Giulio; Dupertuis, Frederic; Durante, Paolo; Dzhelyadin, Rustem; Dziurda, Agnieszka; Dzyuba, Alexey; Easo, Sajan; Egede, Ulrik; Egorychev, Victor; Eidelman, Semen; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; El Rifai, Ibrahim; Elsasser, Christian; Ely, Scott; Esen, Sevda; Evans, Hannah Mary; Evans, Timothy; Falabella, Antonio; Färber, Christian; Farinelli, Chiara; Farley, Nathanael; Farry, Stephen; Fay, Robert; Ferguson, Dianne; Fernandez Albor, Victor; Ferrari, Fabio; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fiore, Marco; Fiorini, Massimiliano; Firlej, Miroslaw; Fitzpatrick, Conor; Fiutowski, Tomasz; Fol, Philip; Fontana, Marianna; Fontanelli, Flavio; Forty, Roger; Francisco, Oscar; Frank, Markus; Frei, Christoph; Frosini, Maddalena; Fu, Jinlin; Furfaro, Emiliano; Gallas Torreira, Abraham; Galli, Domenico; Gallorini, Stefano; Gambetta, Silvia; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; García Pardiñas, Julián; Garofoli, Justin; Garra Tico, Jordi; Garrido, Lluis; Gascon, David; Gaspar, Clara; Gauld, Rhorry; Gavardi, Laura; Gazzoni, Giulio; Geraci, Angelo; Gerick, David; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gianelle, Alessio; Gianì, Sebastiana; Gibson, Valerie; Giubega, Lavinia-Helena; Gligorov, V.V.; Göbel, Carla; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gotti, Claudio; Grabalosa Gándara, Marc; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graverini, Elena; Graziani, Giacomo; Grecu, Alexandru; Greening, Edward; Gregson, Sam; Griffith, Peter; Grillo, Lucia; Grünberg, Oliver; Gui, Bin; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Haines, Susan; Hall, Samuel; Hamilton, Brian; Hampson, Thomas; Han, Xiaoxue; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; He, Jibo; Head, Timothy; Heijne, Veerle; Hennessy, Karol; Henrard, Pierre; Henry, Louis; Hernando Morata, Jose Angel; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adlène; Hill, Donal; Hoballah, Mostafa; Hombach, Christoph; Hulsbergen, Wouter; Humair, Thibaud; Hussain, Nazim; Hutchcroft, David; Hynds, Daniel; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jaeger, Andreas; Jalocha, Pawel; Jans, Eddy; Jawahery, Abolhassan; Jing, Fanfan; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Jurik, Nathan; Kandybei, Sergii; Kanso, Walaa; Karacson, Matthias; Karbach, Moritz; Karodia, Sarah; Kelsey, Matthew; Kenyon, Ian; Kenzie, Matthew; Ketel, Tjeerd; Khanji, Basem; Khurewathanakul, Chitsanu; Klaver, Suzanne; Klimaszewski, Konrad; Kochebina, Olga; Kolpin, Michael; Komarov, Ilya; Koopman, Rose; Koppenburg, Patrick; Kravchuk, Leonid; Kreplin, Katharina; Kreps, Michal; Krocker, Georg; Krokovny, Pavel; Kruse, Florian; Kucewicz, Wojciech; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kurek, Krzysztof; Kvaratskheliya, Tengiz; La Thi, Viet Nga; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lambert, Dean; Lambert, Robert W; Lanfranchi, Gaia; Langenbruch, Christoph; Langhans, Benedikt; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Lees, Jean-Pierre; Lefèvre, Regis; Leflat, Alexander; Lefrançois, Jacques; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Yiming; Likhomanenko, Tatiana; Liles, Myfanwy; Lindner, Rolf; Linn, Christian; Lionetto, Federica; Liu, Bo; Lohn, Stefan; Longstaff, Iain; Lopes, Jose; Lucchesi, Donatella; Luo, Haofei; Lupato, Anna; Luppi, Eleonora; Lupton, Oliver; Machefert, Frederic; Machikhiliyan, Irina V; Maciuc, Florin; Maev, Oleg; Malde, Sneha; Malinin, Alexander; Manca, Giulia; Mancinelli, Giampiero; Manning, Peter Michael; Mapelli, Alessandro; Maratas, Jan; Marchand, Jean François; Marconi, Umberto; Marin Benito, Carla; Marino, Pietro; Märki, Raphael; Marks, Jörg; Martellotti, Giuseppe; Martinelli, Maurizio; Martinez Santos, Diego; Martinez Vidal, Fernando; Martins Tostes, Danielle; Massafferri, André; Matev, Rosen; Mathe, Zoltan; Matteuzzi, Clara; Mauri, Andrea; Maurin, Brice; Mazurov, Alexander; McCann, Michael; McCarthy, James; McNab, Andrew; McNulty, Ronan; McSkelly, Ben; Meadows, Brian; Meier, Frank; Meissner, Marco; Merk, Marcel; Milanes, Diego Alejandro; Minard, Marie-Noelle; Mitzel, Dominik Stefan; Molina Rodriguez, Josue; Monteil, Stephane; Morandin, Mauro; Morawski, Piotr; Mordà, Alessandro; Morello, Michael Joseph; Moron, Jakub; Morris, Adam Benjamin; Mountain, Raymond; Muheim, Franz; Müller, Janine; Müller, Katharina; Müller, Vanessa; Mussini, Manuel; Muster, Bastien; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nasteva, Irina; Needham, Matthew; Neri, Nicola; Neubert, Sebastian; Neufeld, Niko; Neuner, Max; Nguyen, Anh Duc; Nguyen, Thi-Dung; Nguyen-Mau, Chung; Niess, Valentin; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Novoselov, Alexey; O'Hanlon, Daniel Patrick; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Ogilvy, Stephen; Okhrimenko, Oleksandr; Oldeman, Rudolf; Onderwater, Gerco; Osorio Rodrigues, Bruno; Otalora Goicochea, Juan Martin; Otto, Adam; Owen, Patrick; Oyanguren, Maria Aranzazu; Palano, Antimo; Palombo, Fernando; Palutan, Matteo; Panman, Jacob; Papanestis, Antonios; Pappagallo, Marco; Pappalardo, Luciano; Parkes, Christopher; Passaleva, Giovanni; Patel, Girish; Patel, Mitesh; Patrignani, Claudia; Pearce, Alex; Pellegrino, Antonio; Penso, Gianni; Pepe Altarelli, Monica; Perazzini, Stefano; Perret, Pascal; Pescatore, Luca; Petridis, Konstantinos; Petrolini, Alessandro; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pilař, Tomas; Pinci, Davide; Pistone, Alessandro; Playfer, Stephen; Plo Casasus, Maximo; Poikela, Tuomas; Polci, Francesco; Poluektov, Anton; Polyakov, Ivan; Polycarpo, Erica; Popov, Alexander; Popov, Dmitry; Popovici, Bogdan; Potterat, Cédric; Price, Eugenia; Price, Joseph David; Prisciandaro, Jessica; Pritchard, Adrian; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Punzi, Giovanni; Qian, Wenbin; Quagliani, Renato; Rachwal, Bartolomiej; Rademacker, Jonas; Rakotomiaramanana, Barinjaka; Rama, Matteo; Rangel, Murilo; Raniuk, Iurii; Rauschmayr, Nathalie; Raven, Gerhard; Redi, Federico; Reichert, Stefanie; Reid, Matthew; dos Reis, Alberto; Ricciardi, Stefania; Richards, Sophie; Rihl, Mariana; Rinnert, Kurt; Rives Molina, Vincente; Robbe, Patrick; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Perez, Pablo; Roiser, Stefan; Romanovsky, Vladimir; Romero Vidal, Antonio; Rotondo, Marcello; Rouvinet, Julien; Ruf, Thomas; Ruiz, Hugo; Ruiz Valls, Pablo; Saborido Silva, Juan Jose; Sagidova, Naylya; Sail, Paul; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanchez Mayordomo, Carlos; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santovetti, Emanuele; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Saunders, Daniel Martin; Savrina, Darya; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmelzer, Timon; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Semennikov, Alexander; Sepp, Indrek; Serra, Nicola; Serrano, Justine; Sestini, Lorenzo; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Vladimir; Shires, Alexander; Silva Coutinho, Rafael; Simi, Gabriele; Sirendi, Marek; Skidmore, Nicola; Skillicorn, Ian; Skwarnicki, Tomasz; Smith, Edmund; Smith, Eluned; Smith, Jackson; Smith, Mark; Snoek, Hella; Sokoloff, Michael; Soler, Paul; Soomro, Fatima; Souza, Daniel; Souza De Paula, Bruno; Spaan, Bernhard; Spradlin, Patrick; Sridharan, Srikanth; Stagni, Federico; Stahl, Marian; Stahl, Sascha; Steinkamp, Olaf; Stenyakin, Oleg; Sterpka, Christopher Francis; Stevenson, Scott; Stoica, Sabin; Stone, Sheldon; Storaci, Barbara; Stracka, Simone; Straticiuc, Mihai; Straumann, Ulrich; Stroili, Roberto; Sun, Liang; Sutcliffe, William; Swientek, Krzysztof; Swientek, Stefan; Syropoulos, Vasileios; Szczekowski, Marek; Szczypka, Paul; Szumlak, Tomasz; T'Jampens, Stephane; Tekampe, Tobias; Teklishyn, Maksym; Tellarini, Giulia; Teubert, Frederic; Thomas, Christopher; Thomas, Eric; van Tilburg, Jeroen; Tisserand, Vincent; Tobin, Mark; Todd, Jacob; Tolk, Siim; Tomassetti, Luca; Tonelli, Diego; Topp-Joergensen, Stig; Torr, Nicholas; Tournefier, Edwige; Tourneur, Stephane; Trabelsi, Karim; Tran, Minh Tâm; Tresch, Marco; Trisovic, Ana; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tuning, Niels; Ubeda Garcia, Mario; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vacca, Claudia; Vagnoni, Vincenzo; Valenti, Giovanni; Vallier, Alexis; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vázquez Sierra, Carlos; Vecchi, Stefania; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Vesterinen, Mika; Viaud, Benoit; Vieira, Daniel; Vieites Diaz, Maria; Vilasis-Cardona, Xavier; Vollhardt, Achim; Volyanskyy, Dmytro; Voong, David; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; de Vries, Jacco; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Walsh, John; Wandernoth, Sebastian; Wang, Jianchun; Ward, David; Watson, Nigel; Websdale, David; Weiden, Andreas; Whitehead, Mark; Wiedner, Dirk; Wilkinson, Guy; Wilkinson, Michael; Williams, Mark Richard James; Williams, Matthew; Williams, Mike; Wilson, Fergus; Wimberley, Jack; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wright, Simon; Wyllie, Kenneth; Xie, Yuehong; Xu, Zhirui; Yang, Zhenwei; Yuan, Xuhao; Yushchenko, Oleg; Zangoli, Maria; Zavertyaev, Mikhail; Zhang, Liming; Zhang, Yanxi; Zhelezov, Alexey; Zhokhov, Anatoly; Zhong, Liang

    2015-12-15

    A search is performed for heavy long-lived charged particles using 3.0 fb$^{-1}$ of pp collisions collected at $\\sqrt{s}$= 7 and 8 TeV with the LHCb detector. The search is mainly based on the response of the ring imaging Cherenkovdetectors to distinguish the heavy, slow-moving particles from muons. No evidence is found for the production of such long-lived states. The results are expressed as limits on the Drell-Yan production of pairs of long-lived particles, with both particles in the LHCb pseudorapidity acceptance, $1.8 < \\eta < 4.9$. The mass-dependent cross-section upper limits are in the range 2-4 fb (at 95\\% CL) for masses between 124 and 309 GeV/c$^2$.

  19. Stereotactic radiosurgery for spinal metastases: a literature review

    International Nuclear Information System (INIS)

    Joaquim, Andrei Fernandes; Ghizoni, Enrico; Tedeschi, Helder; Pereira, Eduardo Baldon; Giacomini, Leonardo Abdala

    2013-01-01

    Objective: The spine is the most common location for bone metastases. Since cure is not possible, local control and relief of symptoms is the basis for treatment, which is grounded on the use of conventional radiotherapy. Recently, spinal radiosurgery has been proposed for the local control of spinal metastases, whether as primary or salvage treatment. Consequently, we carried out a literature review in order to analyze the indications, efficacy, and safety of radiosurgery in the treatment of spinal metastases. Methods: We have reviewed the literature using the PubMed gateway with data from the Medline library on studies related to the use of radiosurgery in treatment of bone metastases in spine. The studies were reviewed by all the authors and classified as to level of evidence, using the criterion defined by Wright. Results: The indications found for radiosurgery were primary control of epidural metastases (evidence level II), myeloma (level III), and metastases known to be poor responders to conventional radiotherapy – melanoma and renal cell carcinoma (level III). Spinal radiosurgery was also proposed for salvage treatment after conventional radiotherapy (level II). There is also some evidence as to the safety and efficacy of radiosurgery in cases of extramedullar and intramedullar intradural metastatic tumors (level III) and after spinal decompression and stabilization surgery. Conclusion: Radiosurgery can be used in primary or salvage treatment of spinal metastases, improving local disease control and patient symptoms. It should also be considered as initial treatment for radioresistant tumors, such as melanoma and renal cell carcinoma. (author)

  20. Stereotactic radiosurgery and its potential in neurological practice: our first experience

    International Nuclear Information System (INIS)

    Vladarova, D.

    1991-01-01

    The history of radiosurgery of the brain, and experience with the use of beams of ionizing radiation in the therapy of intracranial tumors and arteriovenous malformations are dealt with. Leksell's gamma knife and the way of its use are described. Techniques of stereotactically directed narrow gamma beams with a steep radiation dose gradient serve to subject sharply bounded volumes of tissue to high radiation doses. Owing to a system of collimators, the effect of radiation on the surrounding tissues is negligible. The whole procedure, including the previous angiography and the corresponding calculations, takes 5 to 30 minutes. The latent time after the surgery during which a complete obliteration of the pathological blood vessels takes place is a drawback; this latent time is typically from 4 months to 2 years. World experience in the therapy by this method and the first two cases of patients in Czechoslovakia are described. (M.D.). 1 fig., 12 refs

  1. Intracranial osteosarcoma after radiosurgery. Case report

    International Nuclear Information System (INIS)

    Sanno, Naoko; Hayashi, Shinkichi; Shimura, Toshiro; Maeda, Shotaro; Teramoto, Akira

    2004-01-01

    A 56-year-old woman presented with an intracranial osteosarcoma at the site of previous radiosurgery, manifesting as sudden onset of headache and left hemiparesis with aphasia. She had a previous history of stereotactic radiosurgery for an intracranial tumor under a diagnosis of falx meningioma. Computed tomography showed intratumoral and peritumoral hemorrhage at the right parietofrontal region. Gross total resection of the tumor with hematoma was performed. The histological diagnosis was osteosarcoma. Sarcomatous change is a rare complication of radiotherapy. This case illustrates that osteosarcoma may develop years after radiosurgery for benign brain neoplasm. (author)

  2. Stereotactic Radiosurgery for Poor Performance Status Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kubicek, Gregory J., E-mail: kubicek-gregory@cooperhealth.edu [Department of Radiation Oncology, Cooper University Hospital, Camden, New Jersey (United States); Turtz, Alan [Department of Neurological Surgery, Cooper University Hospital, Camden, New Jersey (United States); Xue, Jinyu; Patel, Ashish; Richards, Gregory; LaCouture, Tamara [Department of Radiation Oncology, Cooper University Hospital, Camden, New Jersey (United States); Cappelli, Louis; Diestelkamp, Tim [Rowan Graduate School, Camden, New Jersey (United States); Saraiya, Piya [Department of Diagnostic Radiology, Cooper University Hospital, Camden, New Jersey (United States); Bexon, Anne [Department of Neurological Surgery, Cooper University Hospital, Camden, New Jersey (United States); Lerman, Nati [Department of Medical Oncology, Cooper University Hospital, Camden, New Jersey (United States); Goldman, Howard Warren [Department of Neurological Surgery, Cooper University Hospital, Camden, New Jersey (United States)

    2016-07-01

    Purpose: Patients with poor performance status (PS), usually defined as a Karnofsky Performance Status of 60 or less, were not eligible for randomized stereotactic radiosurgery (SRS) studies, and many guidelines suggest that whole-brain radiation therapy (WBRT) is the most appropriate treatment for poor PS patients. Methods and Materials: In this retrospective review of our SRS database, we identified 36 patients with PS of 60 or less treated with SRS for central nervous system (CNS) metastatic disease. PS, as defined by the Karnofsky Performance Status, was 60 (27 patients), 50 (8 patients), or 40 (1 patient). The median number of CNS lesions treated was 3. Results: Median overall survival (OS) was 7.2 months (range, 0.73-25.6 months). Fifteen patients (41%) were alive at 6 months, and 6 patients (16.6%) were alive at 1 year. There was no difference in OS in patients who underwent previous WBRT. There were no local failures or cases of radiation toxicity. Distant CNS failures were seen in 9 patients (25%). Conclusions: Our patients with poor PS had reasonable median OS and relatively low distant CNS failure rates. Patients in this patient population may be ideal candidates for SRS compared with WBRT given the low incidence of distant failure over their remaining lives and the favorable logistics of single-fraction treatment for these patients with debility and their caregivers.

  3. Systematics of Charged Particle Production in Heavy-Ion Collisions with the PHOBOS Detector at Rhic

    Science.gov (United States)

    Steinberg, Peter A.; Back, B. B.; Baker, M. D.; Barton, D. S.; Betts, R. R.; Bindel, R.; Budzanowski, A.; Busza, W.; Carroll, A.; Corbo, J.; Decowski, M. P.; Garcia, E.; George, N.; Gulbrandsen, K.; Gushue, S.; Halliwell, C.; Hamblen, J.; Henderson, C.; Hicks, D.; Hofman, D.; Hollis, R. S.; Hołyński, R.; Holzman, B.; Iordanova, A.; Johnson, E.; Kane, J.; Katzy, J.; Khan, N.; Kucewicz, W.; Kulinich, P.; Kuo, C. M.; Lin, W. T.; Manly, S.; McLeod, D.; Michałowski, J.; Mignerey, A.; Mülmenstädt, J.; Nouicer, R.; Olszewski, A.; Pak, R.; Park, I. C.; Pernegger, H.; Rafelski, M.; Rbeiz, M.; Reed, C.; Remsberg, L. P.; Reuter, M.; Roland, C.; Roland, G.; Rosenberg, L.; Sagerer, J.; Sarin, P.; Sawicki, P.; Skulski, W.; Steadman, S. G.; Steinberg, P.; Stephans, G. S. F.; Stodulski, M.; Sukhanov, A.; Tang, J.-L.; Teng, R.; Trzupek, A.; Vale, C.; van Nieuwenhuizen, G. J.; Verdier, R.; Wadsworth, B.; Wolfs, F. L. H.; Wosiek, B.; Woźniak, K.; Wuosmaa, A. H.; Wysłouch, B.

    2002-03-01

    The multiplicity of charged particles produced in Au+Au collisions as a function of energy, centrality, rapidity and azimuthal angle has been measured with the PHOBOS detector at RHIC. These results contribute to our understanding of the initial state of heavy ion collisions and provide a means to compare basic features of particle production in nuclear collisions with more elementary systems.

  4. Transverse energy and charged particle production in heavy-ion collisions: from RHIC to LHC

    International Nuclear Information System (INIS)

    Sahoo, Raghunath; Mishra, Aditya Nath

    2014-01-01

    We study the charged particle and transverse energy production mechanism from AGS, SPS, Relativistic Heavy-Ion Collider (RHIC) to Large Hadron Collider (LHC) energies in the framework of nucleon and quark participants. At RHIC and LHC energies, the number of nucleons-normalized charged particle and transverse energy density in pseudorapidity, which shows a monotonic rise with centrality, turns out to be an almost centrality independent scaling behavior when normalized to the number of participant quarks. A universal function which is a combination of logarithmic and power-law, describes well the charged particle and transverse energy production both at nucleon and quark participant level for the whole range of collision energies. Energy dependent production mechanisms are discussed both for nucleonic and partonic level. Predictions are made for the pseudorapidity densities of transverse energy, charged particle multiplicity and their ratio (the barometric observable, [dE T /dη]/[dN ch /dη] ≡ E T /N ch ) at mid-rapidity for Pb + Pb collisions at √s NN = 5.5 TeV. A comparison with models based on gluon saturation and statistical hadron gas is made for the energy dependence of E T /N ch . (author)

  5. WE-A-304-00: Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    2015-01-01

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB

  6. WE-A-304-00: Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Future directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB.

  7. Search for long-lived heavy charged particles using a ring imaging Cherenkov technique at LHCb.

    Science.gov (United States)

    Aaij, R; Adeva, B; Adinolfi, M; Affolder, A; Ajaltouni, Z; Akar, S; Albrecht, J; Alessio, F; Alexander, M; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amerio, S; Amhis, Y; An, L; Anderlini, L; Anderson, J; Andreotti, M; Andrews, J E; Appleby, R B; Aquines Gutierrez, O; Archilli, F; d'Argent, P; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Baalouch, M; Bachmann, S; Back, J J; Badalov, A; Baesso, C; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Batozskaya, V; Battista, V; Bay, A; Beaucourt, L; Beddow, J; Bedeschi, F; Bediaga, I; Bel, L J; Belyaev, I; Ben-Haim, E; Bencivenni, G; Benson, S; Benton, J; Berezhnoy, A; Bernet, R; Bertolin, A; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Birnkraut, A; Bizzeti, A; Blake, T; Blanc, F; Blouw, J; Blusk, S; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Borsato, M; Bowcock, T J V; Bowen, E; Bozzi, C; Brett, D; Britsch, M; Britton, T; Brodzicka, J; Brook, N H; Bursche, A; Buytaert, J; Cadeddu, S; Calabrese, R; Calvi, M; Calvo Gomez, M; Campana, P; Campora Perez, D; Capriotti, L; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carniti, P; Carson, L; Carvalho Akiba, K; Casanova Mohr, R; Casse, G; Cassina, L; Castillo Garcia, L; Cattaneo, M; Cauet, Ch; Cavallero, G; Cenci, R; Charles, M; Charpentier, Ph; Chefdeville, M; Chen, S; Cheung, S F; Chiapolini, N; Chrzaszcz, M; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coco, V; Cogan, J; Cogneras, E; Cogoni, V; Cojocariu, L; Collazuol, G; Collins, P; Comerma-Montells, A; Contu, A; Cook, A; Coombes, M; Coquereau, S; Corti, G; Corvo, M; Counts, I; Couturier, B; Cowan, G A; Craik, D C; Crocombe, A; Cruz Torres, M; Cunliffe, S; Currie, R; D'Ambrosio, C; Dalseno, J; David, P N Y; Davis, A; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Silva, W; De Simone, P; Dean, C T; Decamp, D; Deckenhoff, M; Del Buono, L; Déléage, N; Derkach, D; Deschamps, O; Dettori, F; Dey, B; Di Canto, A; Di Ruscio, F; Dijkstra, H; Donleavy, S; Dordei, F; Dorigo, M; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dreimanis, K; Dujany, G; Dupertuis, F; Durante, P; Dzhelyadin, R; Dziurda, A; Dzyuba, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; El Rifai, I; Elsasser, Ch; Ely, S; Esen, S; Evans, H M; Evans, T; Falabella, A; Färber, C; Farinelli, C; Farley, N; Farry, S; Fay, R; Ferguson, D; Fernandez Albor, V; Ferrari, F; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fiore, M; Fiorini, M; Firlej, M; Fitzpatrick, C; Fiutowski, T; Fol, P; Fontana, M; Fontanelli, F; Forty, R; Francisco, O; Frank, M; Frei, C; Frosini, M; Fu, J; Furfaro, E; Gallas Torreira, A; Galli, D; Gallorini, S; Gambetta, S; Gandelman, M; Gandini, P; Gao, Y; García Pardiñas, J; Garofoli, J; Garra Tico, J; Garrido, L; Gascon, D; Gaspar, C; Gauld, R; Gavardi, L; Gazzoni, G; Geraci, A; Gerick, D; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gianelle, A; Gianì, S; Gibson, V; Giubega, L; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gotti, C; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graverini, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Griffith, P; Grillo, L; Grünberg, O; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hall, S; Hamilton, B; Hampson, T; Han, X; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Harrison, J; He, J; Head, T; Heijne, V; Hennessy, K; Henrard, P; Henry, L; Hernando Morata, J A; van Herwijnen, E; Heß, M; Hicheur, A; Hill, D; Hoballah, M; Hombach, C; Hulsbergen, W; Humair, T; Hussain, N; Hutchcroft, D; Hynds, D; Idzik, M; Ilten, P; Jacobsson, R; Jaeger, A; Jalocha, J; Jans, E; Jawahery, A; Jing, F; John, M; Johnson, D; Jones, C R; Joram, C; Jost, B; Jurik, N; Kandybei, S; Kanso, W; Karacson, M; Karbach, T M; Karodia, S; Kelsey, M; Kenyon, I R; Kenzie, M; Ketel, T; Khanji, B; Khurewathanakul, C; Klaver, S; Klimaszewski, K; Kochebina, O; Kolpin, M; Komarov, I; Koopman, R F; Koppenburg, P; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kucewicz, W; Kucharczyk, M; Kudryavtsev, V; Kurek, K; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanfranchi, G; Langenbruch, C; Langhans, B; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J P; Lefèvre, R; Leflat, A; Lefrançois, J; Leroy, O; Lesiak, T; Leverington, B; Li, Y; Likhomanenko, T; Liles, M; Lindner, R; Linn, C; Lionetto, F; Liu, B; Lohn, S; Longstaff, I; Lopes, J H; Lucchesi, D; Luo, H; Lupato, A; Luppi, E; Lupton, O; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Malde, S; Malinin, A; Manca, G; Mancinelli, G; Manning, P; Mapelli, A; Maratas, J; Marchand, J F; Marconi, U; Marin Benito, C; Marino, P; Märki, R; Marks, J; Martellotti, G; Martinelli, M; Martinez Santos, D; Martinez Vidal, F; Martins Tostes, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Mauri, A; Maurin, B; Mazurov, A; McCann, M; McCarthy, J; McNab, A; McNulty, R; McSkelly, B; Meadows, B; Meier, F; Meissner, M; Merk, M; Milanes, D A; Minard, M N; Mitzel, D S; Molina Rodriguez, J; Monteil, S; Morandin, M; Morawski, P; Mordà, A; Morello, M J; Moron, J; Morris, A B; Mountain, R; Muheim, F; Müller, J; Müller, K; Müller, V; Mussini, M; Muster, B; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Needham, M; Neri, N; Neubert, S; Neufeld, N; Neuner, M; Nguyen, A D; Nguyen, T D; Nguyen-Mau, C; Niess, V; Niet, R; Nikitin, N; Nikodem, T; Novoselov, A; O'Hanlon, D P; Oblakowska-Mucha, A; Obraztsov, V; Ogilvy, S; Okhrimenko, O; Oldeman, R; Onderwater, C J G; Osorio Rodrigues, B; Otalora Goicochea, J M; Otto, A; Owen, P; Oyanguren, A; Palano, A; Palombo, F; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Pappalardo, L L; Parkes, C; Passaleva, G; Patel, G D; Patel, M; Patrignani, C; Pearce, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perret, P; Pescatore, L; Petridis, K; Petrolini, A; Picatoste Olloqui, E; Pietrzyk, B; Pilař, T; Pinci, D; Pistone, A; Playfer, S; Plo Casasus, M; Poikela, T; Polci, F; Poluektov, A; Polyakov, I; Polycarpo, E; Popov, A; Popov, D; Popovici, B; Potterat, C; Price, E; Price, J D; Prisciandaro, J; Pritchard, A; Prouve, C; Pugatch, V; Puig Navarro, A; Punzi, G; Qian, W; Quagliani, R; Rachwal, B; Rademacker, J H; Rakotomiaramanana, B; Rama, M; Rangel, M S; Raniuk, I; Rauschmayr, N; Raven, G; Redi, F; Reichert, S; Reid, M M; Dos Reis, A C; Ricciardi, S; Richards, S; Rihl, M; Rinnert, K; Rives Molina, V; Robbe, P; Rodrigues, A B; Rodrigues, E; Rodriguez Perez, P; Roiser, S; Romanovsky, V; Romero Vidal, A; Rotondo, M; Rouvinet, J; Ruf, T; Ruiz, H; Ruiz Valls, P; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salustino Guimaraes, V; Sanchez Mayordomo, C; Sanmartin Sedes, B; Santacesaria, R; Santamarina Rios, C; Santovetti, E; Sarti, A; Satriano, C; Satta, A; Saunders, D M; Savrina, D; Schiller, M; Schindler, H; Schlupp, M; Schmelling, M; Schmelzer, T; Schmidt, B; Schneider, O; Schopper, A; Schune, M H; Schwemmer, R; Sciascia, B; Sciubba, A; Semennikov, A; Sepp, I; Serra, N; Serrano, J; Sestini, L; Seyfert, P; Shapkin, M; Shapoval, I; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, V; Shires, A; Silva Coutinho, R; Simi, G; Sirendi, M; Skidmore, N; Skillicorn, I; Skwarnicki, T; Smith, E; Smith, E; Smith, J; Smith, M; Snoek, H; Sokoloff, M D; Soler, F J P; Soomro, F; Souza, D; Souza De Paula, B; Spaan, B; Spradlin, P; Sridharan, S; Stagni, F; Stahl, M; Stahl, S; Steinkamp, O; Stenyakin, O; Sterpka, F; Stevenson, S; Stoica, S; Stone, S; Storaci, B; Stracka, S; Straticiuc, M; Straumann, U; Stroili, R; Sun, L; Sutcliffe, W; Swientek, K; Swientek, S; Syropoulos, V; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Tekampe, T; Teklishyn, M; Tellarini, G; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Todd, J; Tolk, S; Tomassetti, L; Tonelli, D; Topp-Joergensen, S; Torr, N; Tournefier, E; Tourneur, S; Trabelsi, K; Tran, M T; Tresch, M; Trisovic, A; Tsaregorodtsev, A; Tsopelas, P; Tuning, N; Ubeda Garcia, M; Ukleja, A; Ustyuzhanin, A; Uwer, U; Vacca, C; Vagnoni, V; Valenti, G; Vallier, A; Vazquez Gomez, R; Vazquez Regueiro, P; Vázquez Sierra, C; Vecchi, S; Velthuis, J J; Veltri, M; Veneziano, G; Vesterinen, M; Viaud, B; Vieira, D; Vieites Diaz, M; Vilasis-Cardona, X; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Vorobyev, V; Voß, C; de Vries, J A; Waldi, R; Wallace, C; Wallace, R; Walsh, J; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Websdale, D; Weiden, A; Whitehead, M; Wiedner, D; Wilkinson, G; Wilkinson, M; Williams, M; Williams, M P; Williams, M; Wilson, F F; Wimberley, J; Wishahi, J; Wislicki, W; Witek, M; Wormser, G; Wotton, S A; Wright, S; Wyllie, K; Xie, Y; Xu, Z; Yang, Z; Yuan, X; Yushchenko, O; Zangoli, M; Zavertyaev, M; Zhang, L; Zhang, Y; Zhelezov, A; Zhokhov, A; Zhong, L

    A search is performed for heavy long-lived charged particles using 3.0 [Formula: see text] of proton-proton collisions collected at [Formula: see text][Formula: see text] 7 and 8  TeV with the LHCb detector. The search is mainly based on the response of the ring imaging Cherenkov detectors to distinguish the heavy, slow-moving particles from muons. No evidence is found for the production of such long-lived states. The results are expressed as limits on the Drell-Yan production of pairs of long-lived particles, with both particles in the LHCb pseudorapidity acceptance, [Formula: see text]. The mass-dependent cross-section upper limits are in the range 2-4 fb (at 95 % CL) for masses between 14 and 309 [Formula: see text].

  8. 3D quantitative assessment of response to fractionated stereotactic radiotherapy and single-session stereotactic radiosurgery of vestibular schwannoma

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T. [The Johns Hopkins Hospital School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of Neuroradiology, Baltimore, MD (United States); University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Neuroradiology, Hamburg (Germany); Chapiro, J. [The Johns Hopkins Hospital School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of Interventional Radiology, Baltimore, MD (United States); Lin, M. [Philips Research North America, Ultrasound Imaging and Interventions (UII), Briarcliff Manor, NY (United States); Geschwind, J.F. [The Johns Hopkins Hospital School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of Interventional Radiology, Baltimore, MD (United States); Yale University School of Medicine, Department of Radiology and Imaging Science, New Haven, CT (United States); Kleinberg, L. [The Johns Hopkins University School of Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD (United States); Rigamonti, D.; Jusue-Torres, I.; Marciscano, A.E. [The Johns Hopkins University School of Medicine, Department of Neurological Surgery, Baltimore, MD (United States); Yousem, D.M. [The Johns Hopkins Hospital School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of Neuroradiology, Baltimore, MD (United States)

    2016-03-15

    To determine clinical outcome of patients with vestibular schwannoma (VS) after treatment with fractionated stereotactic radiotherapy (FSRT) and single-session stereotactic radiosurgery (SRS) by using 3D quantitative response assessment on MRI. This retrospective analysis included 162 patients who underwent radiation therapy for sporadic VS. Measurements on T1-weighted contrast-enhanced MRI (in 2-year post-therapy intervals: 0-2, 2-4, 4-6, 6-8, 8-10, 10-12 years) were taken for total tumour volume (TTV) and enhancing tumour volume (ETV) based on a semi-automated technique. Patients were considered non-responders (NRs) if they required subsequent microsurgical resection or developed radiological progression and tumour-related symptoms. Median follow-up was 4.1 years (range: 0.4-12.0). TTV and ETV decreased for both the FSRT and SRS groups. However, only the FSRT group achieved significant tumour shrinkage (p < 0.015 for TTV, p < 0.005 for ETV over time). The 11 NRs showed proportionally greater TTV (median TTV pre-treatment: 0.61 cm{sup 3}, 8-10 years after: 1.77 cm{sup 3}) and ETV despite radiation therapy compared to responders (median TTV pre-treatment: 1.06 cm{sup 3}; 10-12 years after: 0.81 cm{sup 3}; p = 0.001). 3D quantification of VS showed a significant decrease in TTV and ETV on FSRT-treated patients only. NR had significantly greater TTV and ETV over time. (orig.)

  9. Stereotactic radiosurgery vs. fractionated radiotherapy for tumor control in vestibular schwannoma patients: a systematic review.

    Science.gov (United States)

    Persson, Oscar; Bartek, Jiri; Shalom, Netanel Ben; Wangerid, Theresa; Jakola, Asgeir Store; Förander, Petter

    2017-06-01

    Repeated controlled studies have revealed that stereotactic radiosurgery is better than microsurgery for patients with vestibular schwannoma (VS) 18 years) patients with unilateral VS, followed for a median of >5 years, were eligible for inclusion. After screening titles and abstracts of the 1094 identified articles and systematically reviewing 98 of these articles, 19 were included. Patients with unilateral VS treated with radiosurgery were compared to patients treated with fractionated stereotactic radiotherapy. No randomized controlled trial (RCT) was identified. None of the identified controlled studies comparing SRS with FSRT were eligible according to the inclusion criteria. Nineteen case series on SRS (n = 17) and FSRT (n = 2) were included in the systematic review. Loss of tumor control necessitating a new VS-targeted intervention was found in an average of 5.0% of the patients treated with SRS and in 4.8% treated with FSRT. Mean deterioration ratio for patients with serviceable hearing before treatment was 49% for SRS and 45% for FSRT, respectively. The risk for facial nerve deterioration was 3.6% for SRS and 11.2% for FSRT and for trigeminal nerve deterioration 6.0% for SRS and 8.4% for FSRT. Since these results were obtained from case series, a regular meta-analysis was not attempted. SRS and FSRT are both noninvasive treatment alternatives for patients with VS with low rates of treatment failure in need of rescue therapy. In this selection of patients, the progression-free survival rates were on the order of 92-100% for both treatment options. There is a lack of high-quality studies comparing radiation therapy alternatives for patients with VS. Finally, 19 articles reported long-term tumor control after SRS, while only 2 articles reported long-term FSRT results, making effect estimates more uncertain for FSRT.

  10. Development of 3-D Radiosurgery Planning System Using IBM Personal Computer

    International Nuclear Information System (INIS)

    Suh, Tae Suk; Park, Charn Il; Ha, Sung Whan; Kang, Wee Saing; Suh, Doug Young; Park, Sung Hun

    1993-01-01

    Recently, stereotactic radiosurgery plan is required with the information of 3-D image and dose distribution. A project has been doing if developing LINAC based stereotactic radiosurgery since April 1991. The purpose of this research is to develop 3-D radiosurgery planning system using personal computer. The procedure of this research is based on two steps. The first step is to develop 3-D localization system, which input the image information of the patient, coordinate transformation, the position and shape of target, and patient contour into computer system using CT image and stereotactic frame. The second step is to develop 3-D dose planning system, which compute dose distribution on image plane, display on high resolution monitor both isodose distribution and patient image simultaneously and develop menu-driven planning system. This prototype of radiosurgery planning system was applied recently for several clinical cases. It was shown that our planning system is fast, accurate and efficient while making it possible to handle various kinds of image modalities such as angiography, CT and MRI. It makes it possible to develop general 3-D planning system using beam eye view or CT simulation in radiation therapy in future

  11. Stereotaxic radiosurgery for therapy of arterivenous malformation of the brain

    International Nuclear Information System (INIS)

    Beraha, J.; Feriancic, C.V.; Scaff, L.A.M.

    1987-01-01

    Since march 1983 we are attempting for the first time in Brazil to develop improvements on stereotactic radiosurgery techniques. We have been using the multifocal irradiation method attaching to this purpose the Barcia IV stereotactic frame to a 4 MV linear accelerator. We show details about the centralization technique and the security patterns in our system. From October 1983 to November 1986, 25 patients with arteriovenous malformations of the brain were submitted to a radiosurgery treatment in our service. Good results obtained on the follow-up from one to three years are analysed. (author)

  12. Study of the absorbed dose in small fields with absence of lateral electronic balance in stereotactic radiosurgery and radiotherapy with modulated intensity

    International Nuclear Information System (INIS)

    Vargas V, M. X.

    2013-01-01

    In this thesis we develop and experimental and theoretical study, using semi analytical techniques of the physical dosimetry for small and nonstandard fields for stereotactic radiosurgery (Srs) and intensity modulated radiation therapy (IMRT), with high energy photon beams from a BrainLAB system with cones at Instituto del Cancer SOLCA (Ecuador) and a Tomo Therapy Hi-Art system at Centro Oncologico de Chihuahua (Mexico). (Author)

  13. Cell and tissue kinetics of the subependymal layer in mouse brain following heavy charged particle irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Manley, N.B.; Fabrikant, J.I.; Alpen, E.L.

    1988-12-01

    The following studies investigate the cellular response and cell population kinetics of the subependymal layer in the mouse brain exposed to heavy charged particle irradiation. Partial brain irradiation with helium and neon ions was confined to one cortex of the brain. Both the irradiated and the unirradiated contralateral cortex showed similar disturbances of the cell and tissue kinetics in the subependymal layers. The irradiated hemisphere exhibited histological damage, whereas the unirradiated side appeared normal histologically. This study concerns the cell population and cell cycle kinetics of the subependymal layer in the mouse brain, and the effects of charged particle irradiations on this cell population. Quantitative high resolution autoradiography was used to study the kinetic parameters in this cell layer. This study should help in understanding the effects of these high-energy heavy ions on normal mammalian brain tissue. The response of the mammalian brain exposure to charged particle ionizing radiation may be extremely variable. It varies from minimal physiological changes to overt tissue necrosis depending on a number of factors such as: the administered dose, dose-rate, the volume of the irradiated tissue, and the biological end-point being examined.

  14. Stereotactic radiosurgery: the preferred management for patients with nonvestibular schwannomas?

    International Nuclear Information System (INIS)

    Pollock, Bruce E.; Foote, Robert L.; Stafford, Scott L.

    2002-01-01

    Purpose: To review patient outcomes after radiosurgery of nonvestibular schwannomas. Methods and Materials: From April 1992 to February 2000, 23 patients had radiosurgery at our center for nonvestibular schwannomas. Affected cranial nerves included the trochlear (n=1), trigeminal (n=10), jugular foramen region (n=10), and hypoglossal (n=2). Nine patients had undergone one or more prior tumor resections. One patient had a malignant schwannoma; 2 patients had neurofibromatosis. The median prescription isodose volume was 8.9 cc (range, 0.2 to 17.6 cc). The median tumor margin dose was 18 Gy (range, 12 to 20 Gy); the median maximum dose was 36 Gy (range, 24 to 40 Gy). The median follow-up after radiosurgery was 43 months (range, 12 to 111 months). Results: Twenty-two of 23 tumors (96%) were either smaller (n=12) or unchanged in size (n=10) after radiosurgery. One patient with a malignant schwannoma had tumor progression outside the irradiated volume despite having both radiosurgery and fractionated radiation therapy (50.4 Gy); he died 4 years later. Morbidity related to radiosurgery occurred in 4 patients (17%). Three of 10 patients with trigeminal schwannomas suffered new or worsened trigeminal dysfunction after radiosurgery. One patient with a hypoglossal schwannoma had eustachian tube dysfunction after radiosurgery. No patient with a lower cranial nerve schwannoma developed any hearing loss, facial weakness, or swallowing difficulty after radiosurgery. Conclusions: Although the reported number of patients having radiosurgery for nonvestibular schwannomas is limited, the high tumor control rates demonstrated after vestibular schwannoma radiosurgery should apply to these rare tumors. Compared to historical controls treated with surgical resection, radiosurgery appears to have less treatment-associated morbidity for nonvestibular schwannomas, especially for schwannomas involving the lower cranial nerves

  15. Late clinical and radiological complications of stereotactical radiosurgery of arteriovenous malformations of the brain

    Energy Technology Data Exchange (ETDEWEB)

    Parkhutik, Vera [Hospital Universitario la Fe, Department of Neurology, Valencia (Spain); Universidad Autonoma de Barcelona, PhD Program of the Department of Medicine, Barcelona (Spain); Lago, Aida; Vazquez, Juan Francisco; Tembl, Jose Ignacio [Hospital Universitario la Fe, Department of Neurology, Valencia (Spain); Aparici, Fernando; Guillen, Lourdes; Mainar, Esperanza; Vazquez, Victor [Hospital Universitario la Fe, Department of Neuroradiology, Valencia (Spain)

    2013-04-15

    Post-radiation injury of patients with brain arteriovenous malformations (AVM) include blood-brain barrier breakdown (BBBB), edema, and necrosis. Prevalence, clinical relevance, and response to treatment are poorly known. We present a series of consecutive brain AVM treated with stereotactic radiosurgery describing the appearance of radiation injury and clinical complications. Consecutive patients with annual clinical and radiological follow-up (median length 63 months). Edema and BBBB were classified in four groups (minimal, perilesional, moderate, or severe), and noted together with necrosis. Clinical symptoms of interest were intracranial hypertension, new neurological deficits, new seizures, and brain hemorrhages. One hundred two cases, median age 34 years, 52 % male. Median irradiated volume 3.8 cc, dose to the margin of the nidus 18.5 Gy. Nineteen patients underwent a second radiosurgery. Only 42.2 % patients remained free from radiation injury. Edema was found in 43.1 %, blood-brain barrier breakdown in 20.6 %, necrosis in 6.9 %. Major injury (moderate or severe edema, moderate or severe BBBB, or necrosis) was found in 20 of 102 patients (19.6 %). AVM diameter >3 cm and second radiosurgery were independent predictors. Time to the worst imaging was 60 months. Patients with major radiation injury had a hazard ratio for appearance of focal deficits of 7.042 (p = 0.04), of intracranial hypertension 2.857 (p = 0.025), hemorrhage into occluded nidus 9.009 (p = 0.079), appearance of new seizures not significant. Major radiation injury is frequent and increases the risk of neurological complications. Its late appearance implies that current follow-up protocols need to be extended in time. (orig.)

  16. Hypopituitarism after stereotactic radiosurgery for pituitary adenomas.

    Science.gov (United States)

    Xu, Zhiyuan; Lee Vance, Mary; Schlesinger, David; Sheehan, Jason P

    2013-04-01

    Studies of new-onset Gamma Knife stereotactic radiosurgery (SRS)-induced hypopituitarism in large cohort of pituitary adenoma patients with long-term follow-up are lacking. We investigated the outcomes of SRS for pituitary adenoma patients with regard to newly developed hypopituitarism. This was a retrospective review of patients treated with SRS at the University of Virginia between 1994 and 2006. A total of 262 patients with a pituitary adenoma treated with SRS were reviewed. Thorough endocrine assessment was performed immediately before SRS and in regular follow-ups. Assessment consisted of 24-hour urine free cortisol (patients with Cushing disease), serum adrenocorticotropic hormone, cortisol, follicle-stimulating hormone, luteinizing hormone, insulin-like growth factor-1, growth hormone, testosterone (men), prolactin, thyroid-stimulating hormone, and free T(4). Endocrine remission occurred in 144 of 199 patients with a functioning adenoma. Tumor control rate was 89%. Eighty patients experienced at least 1 axis of new-onset SRS-induced hypopituitarism. The new hypopituitarism rate was 30% based on endocrine follow-up ranging from 6 to 150 months; the actuarial rate of new pituitary hormone deficiency was 31.5% at 5 years after SRS. On univariate and multivariate analyses, variables regarding the increased risk of hypopituitarism included suprasellar extension and higher radiation dose to the tumor margin; there were no correlations among tumor volume, prior transsphenoidal adenomectomy, prior radiation therapy, and age at SRS. SRS provides an effective and safe treatment option for patients with a pituitary adenoma. Higher margin radiation dose to the adenoma and suprasellar extension were 2 independent predictors of SRS-induced hypopituitarism.

  17. Development of stereotactic radiosurgery using carbon beams (carbon-knife)

    Science.gov (United States)

    Keawsamur, Mintra; Matsumura, Akihiko; Souda, Hikaru; Kano, Yosuke; Torikoshi, Masami; Nakano, Takashi; Kanai, Tatsuaki

    2018-02-01

    The aim of this research is to develop a stereotactic-radiosurgery (SRS) technique using carbon beams to treat small intracranial lesions; we call this device the carbon knife. A 2D-scanning method is adapted to broaden a pencil beam to an appropriate size for an irradiation field. A Mitsubishi slow extraction using third order resonance through a rf acceleration system stabilized by a feed-forward scanning beam using steering magnets with a 290 MeV/u initial beam energy was used for this purpose. Ridge filters for spread-out Bragg peaks (SOBPs) with widths of 5 mm, 7.5 mm, and 10 mm were designed to include fluence-attenuation effects. The collimator, which defines field shape, was used to reduce the lateral penumbra. The lateral-penumbra width at the SOBP region was less than 2 mm for the carbon knife. The penumbras behaved almost the same when changing the air gap, but on the other hand, increasing the range-shifter thickness mostly broadened the lateral penumbra. The physical-dose rates were approximate 6 Gy s-1 and 4.5 Gy s-1 for the 10  ×  10 mm2 and 5  ×  5 mm2 collimators, respectively.

  18. Treatment planning optimization for linear accelerator radiosurgery

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Buatti, John M.; Bova, Francis J.; Friedman, William A.; Mendenhall, William M.

    1998-01-01

    Purpose: Linear accelerator radiosurgery uses multiple arcs delivered through circular collimators to produce a nominally spherical dose distribution. Production of dose distributions that conform to irregular lesions or conformally avoid critical neural structures requires a detailed understanding of the available treatment planning parameters. Methods and Materials: Treatment planning parameters that may be manipulated within a single isocenter to provide conformal avoidance and dose conformation to ellipsoidal lesions include differential arc weighting and gantry start/stop angles. More irregular lesions require the use of multiple isocenters. Iterative manipulation of treatment planning variables can be difficult and computationally expensive, especially if the effects of these manipulations are not well defined. Effects of treatment parameter manipulation are explained and illustrated. This is followed by description of the University of Florida Stereotactic Radiosurgery Treatment Planning Algorithm. This algorithm organizes the manipulations into a practical approach for radiosurgery treatment planning. Results: Iterative treatment planning parameters may be efficiently manipulated to achieve optimal treatment plans by following the University of Florida Treatment Planning Algorithm. The ability to produce conformal stereotactic treatment plans using the algorithm is demonstrated for a variety of clinical presentations. Conclusion: The standard dose distribution produced in linear accelerator radiosurgery is spherical, but manipulation of available treatment planning parameters may result in optimal dose conformation. The University of Florida Treatment Planning Algorithm organizes available treatment parameters to efficiently produce conformal radiosurgery treatment plans

  19. Tolerance of the Spinal Cord to Stereotactic Radiosurgery: Insights From Hemangioblastomas

    International Nuclear Information System (INIS)

    Daly, Megan E.; Choi, Clara Y.H.; Gibbs, Iris C.; Adler, John R.; Chang, Steven D.; Lieberson, Robert E.; Soltys, Scott G.

    2011-01-01

    Purpose: To evaluate spinal cord dose-volume effects, we present a retrospective review of stereotactic radiosurgery (SRS) treatments for spinal cord hemangioblastomas. Methods and Materials: From November 2001 to July 2008, 27 spinal hemangioblastomas were treated in 19 patients with SRS. Seventeen tumors received a single fraction with a median dose of 20 Gy (range, 18-30 Gy). Ten lesions were treated using 18-25 Gy in two to three sessions. Cord volumes receiving 8, 10, 12, 14, 16, 18, 20, 22, and 24 Gy and dose to 10, 100, 250, 500, 1000, and 2000 mm 3 of cord were determined. Multisession treatments were converted to single-fraction biologically effective dose (SFBED). Results: Single-fraction median cord D max was 22.7 Gy (range, 17.8-30.9 Gy). Median V10 was 454 mm 3 (range, 226-3543 mm 3 ). Median dose to 500 mm 3 cord was 9.5 Gy (range, 5.3-22.5 Gy). Fractionated median SFBED 3 cord D max was 14.1 Gy 3 (range, 12.3-19.4 Gy 3 ). Potential toxicities included a Grade 2 unilateral foot drop 5 months after SRS and 2 cases of Grade 1 sensory deficits. The actuarial 3-year local tumor control estimate was 86%. Conclusions: Despite exceeding commonly cited spinal cord dose constraints, SRS for spinal hemangioblastomas is safe and effective. Consistent with animal experiments, these data support a partial-volume tolerance model for the human spinal cord. Because irradiated cord volumes were generally small, application of these data to other clinical scenarios should be made cautiously. Further prospective studies of spinal radiosurgery are needed.

  20. Stereotactic Radiosurgery for Cushing Disease: Results of an International, Multicenter Study.

    Science.gov (United States)

    Mehta, Gautam U; Ding, Dale; Patibandla, Mohana Rao; Kano, Hideyuki; Sisterson, Nathaniel; Su, Yan-Hua; Krsek, Michal; Nabeel, Ahmed M; El-Shehaby, Amr; Kareem, Khaled A; Martinez-Moreno, Nuria; Mathieu, David; McShane, Brendan; Blas, Kevin; Kondziolka, Douglas; Grills, Inga; Lee, John Y; Martinez-Alvarez, Roberto; Reda, Wael A; Liscak, Roman; Lee, Cheng-Chia; Lunsford, L Dade; Vance, Mary Lee; Sheehan, Jason P

    2017-11-01

    Cushing disease (CD) due to adrenocorticotropic hormone-secreting pituitary tumors can be a management challenge. To better understand the outcomes of stereotactic radiosurgery (SRS) for CD and define its role in management. International, multicenter, retrospective cohort analysis. Ten medical centers participating in the International Gamma Knife Research Foundation. Patients with CD with >6 months endocrine follow-up. SRS using Gamma Knife radiosurgery. The primary outcome was control of hypercortisolism (defined as normalization of free urinary cortisol). Radiologic response and adverse radiation effects (AREs) were recorded. In total, 278 patients met inclusion criteria, with a mean follow-up of 5.6 years (0.5 to 20.5 years). Twenty-two patients received SRS as a primary treatment of CD. Mean margin dose was 23.7 Gy. Cumulative initial control of hypercortisolism was 80% at 10 years. Mean time to cortisol normalization was 14.5 months. Recurrences occurred in 18% with initial cortisol normalization. Overall, the rate of durable control of hypercortisolism was 64% at 10 years and 68% among patients who received SRS as a primary treatment. AREs included hypopituitarism (25%) and cranial neuropathy (3%). Visual deficits were related to treatment of tumor within the suprasellar cistern (P = 0.01), whereas both visual (P < 0.0001) and nonvisual cranial neuropathy (P = 0.02) were related to prior pituitary irradiation. SRS for CD is well tolerated and frequently results in control of hypercortisolism. However, recurrences can occur. SRS should be considered for patients with persistent hypercortisolism after pituitary surgery and as a primary treatment in those unfit for surgery. Long-term endocrine follow-up is essential after SRS. Copyright © 2017 Endocrine Society

  1. The geometric accuracy of frameless stereotactic radiosurgery using a 6D robotic couch system

    Energy Technology Data Exchange (ETDEWEB)

    Takakura, T; Nakata, M; Yano, S; Fujimoto, T [Division of Clinical Radiology Service, Kyoto University Hospital, Kyoto (Japan); Mizowaki, T; Miyabe, Y; Nakamura, M; Hiraoka, M [Department of Radiation Oncology and Image-applied Therapy, Kyoto University Graduate School of Medicine, Kyoto (Japan)], E-mail: toru1@kuhp.kyoto-u.ac.jp

    2010-01-07

    The aim of this paper is to assess the overall geometric accuracy of the Novalis system using the Robotic Tilt Module in terms of the uncertainty in frameless stereotactic radiotherapy. We analyzed the following three metrics: (1) the correction accuracy of the robotic couch, (2) the uncertainty of the isocenter position with gantry and couch rotation, and (3) the shift in position between the isocenter and central point detected with the ExacTrac x-ray system. Based on the concept of uncertainty, the overall accuracy was calculated from these values. The accuracy in positional correction with the robotic couch was 0.07 {+-} 0.22 mm, the positional shift of the isocenter associated with gantry rotation was 0.35 mm, the positional shift of the isocenter associated with couch rotation was 0.38 mm and the difference in position between the isocenter and the ExacTrac x-ray system was 0.30 mm. The accuracy of intracranial stereotactic radiosurgery with the Novalis system in our clinic was 0.31 {+-} 0.77 mm. The overall geometric accuracy based on the concept of uncertainty was 0.31 {+-} 0.77 mm, which is within the tolerance given in the American Association of Physicists in Medicine report no. 54.

  2. The geometric accuracy of frameless stereotactic radiosurgery using a 6D robotic couch system

    International Nuclear Information System (INIS)

    Takakura, T; Nakata, M; Yano, S; Fujimoto, T; Mizowaki, T; Miyabe, Y; Nakamura, M; Hiraoka, M

    2010-01-01

    The aim of this paper is to assess the overall geometric accuracy of the Novalis system using the Robotic Tilt Module in terms of the uncertainty in frameless stereotactic radiotherapy. We analyzed the following three metrics: (1) the correction accuracy of the robotic couch, (2) the uncertainty of the isocenter position with gantry and couch rotation, and (3) the shift in position between the isocenter and central point detected with the ExacTrac x-ray system. Based on the concept of uncertainty, the overall accuracy was calculated from these values. The accuracy in positional correction with the robotic couch was 0.07 ± 0.22 mm, the positional shift of the isocenter associated with gantry rotation was 0.35 mm, the positional shift of the isocenter associated with couch rotation was 0.38 mm and the difference in position between the isocenter and the ExacTrac x-ray system was 0.30 mm. The accuracy of intracranial stereotactic radiosurgery with the Novalis system in our clinic was 0.31 ± 0.77 mm. The overall geometric accuracy based on the concept of uncertainty was 0.31 ± 0.77 mm, which is within the tolerance given in the American Association of Physicists in Medicine report no. 54.

  3. Cost-effectiveness Analysis of Stereotactic Radiosurgery Alone Versus Stereotactic Radiosurgery with Upfront Whole Brain Radiation Therapy for Brain Metastases.

    Science.gov (United States)

    Kim, H; Rajagopalan, M S; Beriwal, S; Smith, K J

    2017-10-01

    Stereotactic radiosurgery (SRS) alone or upfront whole brain radiation therapy (WBRT) plus SRS are the most commonly used treatment options for one to three brain oligometastases. The most recent randomised clinical trial result comparing SRS alone with upfront WBRT plus SRS (NCCTG N0574) has favoured SRS alone for neurocognitive function, whereas treatment options remain controversial in terms of cognitive decline and local control. The aim of this study was to conduct a cost-effectiveness analysis of these two competing treatments. A Markov model was constructed for patients treated with SRS alone or SRS plus upfront WBRT based on largely randomised clinical trials. Costs were based on 2016 Medicare reimbursement. Strategies were compared using the incremental cost-effectiveness ratio (ICER) and effectiveness was measured in quality-adjusted life years (QALYs). One-way and probabilistic sensitivity analyses were carried out. Strategies were evaluated from the healthcare payer's perspective with a willingness-to-pay threshold of $100 000 per QALY gained. In the base case analysis, the median survival was 9 months for both arms. SRS alone resulted in an ICER of $9917 per QALY gained. In one-way sensitivity analyses, results were most sensitive to variation in cognitive decline rates for both groups and median survival rates, but the SRS alone remained cost-effective for most parameter ranges. Based on the current available evidence, SRS alone was found to be cost-effective for patients with one to three brain metastases compared with upfront WBRT plus SRS. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  4. Hypofractionated stereotactic irradiation. Basic and clinical researches

    International Nuclear Information System (INIS)

    Shibamoto, Yuta; Miyakawa, Akifumi; Iwata, Hiromitsu; Otsuka, Shinya; Ogino, Hiroyuki; Ayakawa, Shiho

    2011-01-01

    Hypofractionated stereotactic radiotherapy (SRT) has a number of biological advantages over single-session radiosurgery. An apparent trend is seen in the clinic towards shift from the latter to the former; however, there is no adequate model to convert single doses to hypofractionated doses. The linear-quadratic model overestimates the effect of single-fraction radiation. This should be kept in mind in evaluating the doses of stereotactic irradiation. ''Biological effective dose'' should not be used in radiosurgery and hypofractionated SRT. Clinically, we have used 3- to 10-fraction SRT for acoustic neuroma and benign skull base tumors using cyberknife and tomotherapy. Preliminary results are encouraging. (author)

  5. Stereotactic radiotherapy in pediatric indications

    International Nuclear Information System (INIS)

    Bernier-Chastagner, V.; Supiot, S.; Carrie, C.; Helfre, S.

    2012-01-01

    Stereotactic radiotherapy is a very high precision procedure, which has been limited to radiosurgery for a long time. Technological improvements allowed the development of radiotherapy in stereotactic conditions, leading to a lot of innovations. Previously indicated for cerebral pathologies, this procedure is now developed for extra-cerebral locations. In paediatrics, stereotactic radiotherapy is still limited, delivered precociously, due to the possibility of long-term late effects that needs to be addressed. This review reports the different useful conditions, technical evolutions, and the current validated paediatric indications, with differences from adults, and future directions. (authors)

  6. Initial clinical results of linac-based stereotactic radiosurgery and stereotactic radiotherapy for pituitary adenomas

    International Nuclear Information System (INIS)

    Mitsumori, Michihide; Shrieve, Dennis C.; Alexander, Eben; Kaiser, Ursula B.; Richardson, Gary E.; Black, Peter McL.; Loeffler, Jay S.

    1998-01-01

    Purpose: To retrospectively evaluate the initial clinical results of stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (SRT) for pituitary adenomas with regard to tumor and hormonal control and adverse effects of the treatment. Subjects and Methods: Forty-eight patients with pituitary adenoma who underwent SRS or SRT between September 1989 and September 1995 were analyzed. Of these, 18 received SRS and 30 received SRT. The median tumor volumes were 1.9 cm 3 for SRS and 5.7 cm 3 for SRT. Eleven of the SRS and 18 of the SRT patients were hormonally active at the time of the initial diagnosis. Four of the SRS and none of the SRT patients had a history of prior radiation therapy. Both SRS and SRT were performed using a dedicated stereotactic 6-MV linear accelerator (LINAC). The dose and normalization used for the SRS varied from 1000 cGy at 85% of the isodose line to 1500 cGy at 65% of the isodose line. For SRT patients, a total dose of 4500 cGy at 90% or 95% of the isodose line was delivered in 25 fractions of 180 cGy daily doses. Results: Disease control--The three year tumor control rate was 91.1% (100% for SRS and 85.3% for SRT). Normalization of the hormonal abnormality was achieved in 47% of the 48 patients (33% for SRS and 54% for SRT). The average time required for normalization was 8.5 months for SRS and 18 months for SRT. Adverse effects--The 3-year rate of freedom from central nervous system adverse effects was 89.7% (72.2% for SRS and 100% for SRT). Three patients who received SRS for a tumor in the cavernous sinus developed a ring enhancement in the temporal lobe as shown by follow-up magnetic resonance imaging. Two of these cases were irreversible and were considered to be radiation necrosis. None of the 48 patients developed new neurocognitive or visual disorders attributable to the irradiation. The incidence of endocrinological adverse effects were similar in the two groups, resulting in 3-year rates of freedom from newly

  7. Characterisation of a plastic scintillation detector to be used in a multicentre stereotactic radiosurgery dosimetry audit

    Science.gov (United States)

    Dimitriadis, A.; Patallo, I. Silvestre; Billas, I.; Duane, S.; Nisbet, A.; Clark, C. H.

    2017-11-01

    Scintillation detectors are considered highly suitable for dosimetric measurement of small fields in radiotherapy due to their near-tissue equivalence and their small size. A commercially available scintillation detector, the Exradin W1 (Standard Imaging, Middleton, USA), has been previously characterised by two independent studies (Beierholm et al., 2014; Carrasco et al., 2015a, 2015b) but the results from these publications differed in some aspects (e.g. energy dependence, long term stability). The respective authors highlighted the need for more studies to be published (Beierholm et al., 2015; Carrasco et al., 2015a, 2015b). In this work, the Exradin W1 was characterised in terms of dose response, dependence on dose rate, energy, temperature and angle of irradiation, and long-term stability. The observed dose linearity, short-term repeatability and temperature dependence were in good agreement with previously published data. Appropriate corrections should therefore be applied, where possible, in order to achieve measurements with low-uncertainty. The angular dependence was characterised along both the symmetrical and polar axis of the detector for the first time in this work and a dose variation of up to 1% was observed. The response of the detector was observed to decrease at a rate of approximately 1.6% kGy-1 for the first 5 kGy delivered, and then stabilised to 0.2% kGy-1 in the subsequent 20 kGy. The main goal of this work was to assess the suitability of the Exradin W1 for use in dose verification measurements for stereotactic radiosurgery. The results obtained confirm that the detector is suitable for use in such situations. The detector is now utilised in a multi-centre stereotactic radiosurgery dosimetric audit, with the application of appropriate correction factors.

  8. Development of a head phantom to be used for quality control in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Barbosa, Nilseia Aparecida

    2010-05-01

    It was designed and developed a geometric acrylic head phantom (GHP) for Quality Assurance (QA) in Stereotactic Radiosurgery (SRS). Inside the phantom there are inserts that are able to accommodate acrylic targets representing the tumor tissue and organ at risk in the region cranial brain, the brain stem. The tumor tissue is represented by two semi-spheres of acrylic with a diameter of 13.0 mm and cavities in the central region for accommodation of a TLD-100 detector and a small radiochromic EBT Gafchromic filmstrip. The brain stem is represented by the two parts of acrylic cylinder with a diameter 18.0 mm, 38.0 mm length and cavities along the central region to accommodate the 5 detectors TLD-100 and yet another of EBT film. The distance tumor - brain stem is 2.0 mm. The experimental setup was filled with water, attached to the stereotactic frame to determine the coordinates of the target and underwent computed tomography (CT). Cf images were transferred to the SRS planning system BrainLab (BrainScan). The contours of the lesion and organ at risk were delineated and, through the technique of multiple circular arcs, the planning was conduced with five arches, one isocenter and a collimator of 17.5 mm from the combination between the table and gantry . The dose delivered to the isocenter of the lesion was 3.0 Gy and the total coverage of tumor volume corresponds to the 75% isodose. This experimental arrangement is subjected to radiosurgery treatment, after which the dosimeters are evaluated and their responses compared with the values of planned doses. The linear accelerator used was a Varian CLlNAC 2300 CID, photon beam of 6 MV, installed at the National Cancer Institute (INCA). For verification of dose distributions in 3D, the films were irradiated in three planes: sagittal, caronal and axial. The .films were scanned and digitized on a scanner Microtek ScanMaker 9800XL model. The dose distributions in irradiated films were compared with the distributions of doses

  9. Response of mouse skin and bone marrow to heavy charged particles

    International Nuclear Information System (INIS)

    Ainsworth, E.J.

    1980-01-01

    Because of the desirability to determine RBE at therapeutically relevant dose levels, our approach was to use a challenge-dose technique. This challenge-dose technique assesses injury accumulation and repair or recovery following administration of comparatively low doses by challenging animals. No previous studies have been conducted using CFU-S irradiated in vivo as a model system to assess the RBE of heavy charged particles for either cell killing or for late effects. The goal of the CFU-S studies reported here was to determine the RBE for cell killing, and to use these data to design experiments to explore the effects of HZE particle dose fractionation on femur CFU-S repopulation and on late effects indicated by a reduction in the size of the CFU-S compartment

  10. Peritumoral Brain Edema after Stereotactic Radiosurgery for Asymptomatic Intracranial Meningiomas: Risks and Pattern of Evolution.

    Science.gov (United States)

    Hoe, Yeon; Choi, Young Jae; Kim, Jeong Hoon; Kwon, Do Hoon; Kim, Chang Jin; Cho, Young Hyun

    2015-10-01

    To investigate the risks and pattern of evolution of peritumoral brain edema (PTE) after stereotactic radiosurgery (SRS) for asymptomatic intracranial meningiomas. A retrospective study was conducted on 320 patients (median age 56 years, range 24-87 years) who underwent primary Gamma Knife radiosurgery for asymptomatic meningiomas between 1998 and 2012. The median tumor volume was 2.7 cc (range 0.2-10.5 cc) and the median follow-up was 48 months (range 24-168 months). Volumetric data sets for tumors and PTE on serial MRIs were analyzed. The edema index (EI) was defined as the ratio of the volume of PTE including tumor to the tumor volume, and the relative edema indices (rEIs) were calculated from serial EIs normalized against the baseline EI. Risk factors for PTE were analyzed using logistic regression. Newly developed or increased PTE was noted in 49 patients (15.3%), among whom it was symptomatic in 28 patients (8.8%). Tumor volume larger than 4.2 cc (pmaking on SRS for asymptomatic meningiomas of large volume (>4.2 cc), of hemispheric location, or with pre-treatment PTE. PTE usually develops within months, reaches its maximum degree until a year, and resolves within 2 years after SRS.

  11. Dosimetry of small circular beams of high energy photons for stereotactic radiosurgery and radiotherapy: the use of small ionization chambers

    International Nuclear Information System (INIS)

    Mazal, A.; Gaboriauid, G.; Zefkili, S.; Rosenwald, J.C.; Boutaudon, S.; Pontvert, D.

    1999-01-01

    The irradiation of small targets in the brain in a singe fraction (radiosurgery) or with a fractionated approach (stereotactic radiosurgery) with small beams of photons requires specific conditions to measure and to model the dosimetric data needed for treatment planning. In this work we present the method and materials adopted in our institution since 1988 to perform the dosimetry of high energy (6-23) circular photon beams with diameters ranging from 10 to 40 mm at the isocenter of linear accelerators, and its evolution as new dosimetric material became commercially available. in circular ionization chambers of small dimensions. We want to answer the following questions: Which are the minimal basic data needed to model small circular beams of high energy photons? Can we extrapolate or convert data from conventional data of larger beams? Which are the detectors well adapted for these kind of measurements and for which range of beam sizes?

  12. IRLED-based patient localization for linac radiosurgery

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Bova, Francis J.; Friedman, William A.; Buatti, John M.; Moore, Russell D.; Mendenhall, William M.

    1998-01-01

    Purpose: Currently, precise stereotactic radiosurgery delivery is possible with the Gamma Knife or floor-stand linear accelerator (linac) systems. Couch-mounted linac radiosurgery systems, while less expensive and more flexible than other radiosurgery delivery systems, have not demonstrated a comparable level of precision. This article reports on the development and testing of an optically guided positioning system designed to improve the precision of patient localization in couch-mounted linac radiosurgery systems. Methods and Materials: The optically guided positioning system relies on detection of infrared light-emitting diodes (IRLEDs) attached to a standard target positioner. The IRLEDs are monitored by a commercially available camera system that is interfaced to a personal computer. An IRLED reference is established at the center of stereotactic space, and the computer reports the current position of the IRLEDs relative to this reference position. Using this readout from the computer, the correct stereotactic coordinate can be set directly. Results: Bench testing was performed to compare the accuracy of the optically guided system with that of a floor-stand system, that can be considered an absolute reference. This testing showed that coordinate localization using the IRLED system to track translations agreed with the absolute to within 0.1 ± 0.1 mm. As rotations for noncoplanar couch angles were included, the inaccuracy was increased to 0.2 ± 0.1 mm. Conclusions: IRLED technology improves the accuracy of patient localization relative to the linac isocenter in comparison with conventional couch-mounted systems. Further, the patient's position can be monitored in real time as the couch is rotated for all treatment angles. Thus, any errors introduced by couch inaccuracies can be detected and corrected

  13. Clinical results in heavy particle radiotherapy

    International Nuclear Information System (INIS)

    Castro, J.R.; Quivey, J.M.; Saunders, W.M.; Woodruff, K.H.; Chen, G.T.Y.; Lyman, J.T.; Pitluck, S.; Tobias, C.A.; Walton, R.E.; Peters, T.C.

    1980-01-01

    The chapter presents an overview of the use of heavy particles in human cancer radiotherapy. The biophysical characteristics and rationale for using heavy charged particle therapy are explored. The clinical experience with carbon, neon, argon and helium are summarized for various types of tumors including carcinomas of the uterine cervix and lung, skin melanomas and metastatic sarcomas. No obvious normal tissue complications have appeared

  14. The semiclassical approximation for L- and M-shell coulomb ionization by heavy charged particles

    International Nuclear Information System (INIS)

    Kocbach, L.

    1975-08-01

    The semiclassical approximation with straight line trajectories is applied to the Coulomb ionization of K-, L- and M-shells by heavy charged particles. The calculational aspects are discussed in detail. Scaling relations for the experimentally relevant quantities are derived. The theoretical predictions are compared with experimental data. The relation of the present work to earlier SCA results and the PWBA results is discussed in detail. (auth)

  15. A modification to the Gill-Thomas-Cosman (GTC) head frame for stereotactic radiosurgery of head and neck and cervical spine sites

    International Nuclear Information System (INIS)

    Qian, G.; Hasala, P.; Rashid, H.; Costantino, T.; Cangiane, L.; Lombardi, E.; Arbit, E; Lederman, G.

    1996-01-01

    PURPOSE/OBJECTIVE: Fractionated Stereotactic Radiosurgery (FSR) is used primarily to treat intracranial lesions. Many tumors which arise at or inferior to the base of skull and about the cervical spine area were not amenable to radiosurgery. Presented is a modification to the GTC head frame which permits stereotactic radiosurgery to be directed at head and neck tumors with accurate reproducible precision. MATERIALS AND METHODS: The original GTC head frame has two fixation points; an anterior individualized dental impression and a posterior occipital plate with a mold contoured to the occipital pertuberance. The height of the occipital plate is adjustable in its vertical plane. However, the position of the dental piece is fixed and, therefore, limits treatment to regions superior. Treatment of head and neck and cervical spine tumors has been accomplished with a modification of the dental apparatus. Presented is our new device; a bracket extension which attaches to the dental piece and allows the head frame to be lowered to multiple desired positions. The occipital plate is elevated accordingly to support the occipital pertuberance. The depth helmet is also modified for quality assurance. A Rando phantom was used to test the accuracy and reproducibility of the new equipment. Bracket extensions lowering the head frame by 3 cm and 8 cm, respectively, were tested for accuracy of relocation on the Rando Phantom. Each extension was tested 20 times and for each individual test 18 depth helmet positions were obtained. RESULTS: The standard deviation of the modified head frame for each depth helmet measurement ranged from 0.05 to 0.35mm (mean 0.20) as compared to the standard deviation for the original GTC head frame which was 0.13 to 0.34mm (mean 0.24). The new device maintains the accuracy and reproducibility of the original GTC head frame. CONCLUSION: The GTC relocatable head frame for FSR has been modified to treat tumors of the head and neck and cervical spine sites

  16. Radical stereotactic radiosurgery with real-time tumor motion tracking in the treatment of small peripheral lung tumors

    Directory of Open Access Journals (Sweden)

    Chang Thomas

    2007-10-01

    Full Text Available Abstract Background Recent developments in radiotherapeutic technology have resulted in a new approach to treating patients with localized lung cancer. We report preliminary clinical outcomes using stereotactic radiosurgery with real-time tumor motion tracking to treat small peripheral lung tumors. Methods Eligible patients were treated over a 24-month period and followed for a minimum of 6 months. Fiducials (3–5 were placed in or near tumors under CT-guidance. Non-isocentric treatment plans with 5-mm margins were generated. Patients received 45–60 Gy in 3 equal fractions delivered in less than 2 weeks. CT imaging and routine pulmonary function tests were completed at 3, 6, 12, 18, 24 and 30 months. Results Twenty-four consecutive patients were treated, 15 with stage I lung cancer and 9 with single lung metastases. Pneumothorax was a complication of fiducial placement in 7 patients, requiring tube thoracostomy in 4. All patients completed radiation treatment with minimal discomfort, few acute side effects and no procedure-related mortalities. Following treatment transient chest wall discomfort, typically lasting several weeks, developed in 7 of 11 patients with lesions within 5 mm of the pleura. Grade III pneumonitis was seen in 2 patients, one with prior conventional thoracic irradiation and the other treated with concurrent Gefitinib. A small statistically significant decline in the mean % predicted DLCO was observed at 6 and 12 months. All tumors responded to treatment at 3 months and local failure was seen in only 2 single metastases. There have been no regional lymph node recurrences. At a median follow-up of 12 months, the crude survival rate is 83%, with 3 deaths due to co-morbidities and 1 secondary to metastatic disease. Conclusion Radical stereotactic radiosurgery with real-time tumor motion tracking is a promising well-tolerated treatment option for small peripheral lung tumors.

  17. Feasibility evaluation of a motion detection system with face images for stereotactic radiosurgery.

    Science.gov (United States)

    Yamakawa, Takuya; Ogawa, Koichi; Iyatomi, Hitoshi; Kunieda, Etsuo

    2011-01-01

    In stereotactic radiosurgery we can irradiate a targeted volume precisely with a narrow high-energy x-ray beam, and thus the motion of a targeted area may cause side effects to normal organs. This paper describes our motion detection system with three USB cameras. To reduce the effect of change in illuminance in a tracking area we used an infrared light and USB cameras that were sensitive to the infrared light. The motion detection of a patient was performed by tracking his/her ears and nose with three USB cameras, where pattern matching between a predefined template image for each view and acquired images was done by an exhaustive search method with a general-purpose computing on a graphics processing unit (GPGPU). The results of the experiments showed that the measurement accuracy of our system was less than 0.7 mm, amounting to less than half of that of our previous system.

  18. Linear accelerator radiosurgery in treatment of central neurocytomas

    International Nuclear Information System (INIS)

    Martin, J.M.; Katati, M.; Arjona, V.; Lopez, E.; Olivares, G.; Hernandez, V.; Bullejos, J.A.; Arregui, G.; Busquier, H.; Minguez, A.

    2003-01-01

    The purpose of this report was to review our experience with stereotactic radiosurgery in the management of patients with residual neurocytomas after initial surgery. Between October 1996 and December 2001, four patients with central neurocytoma were treated by surgery and subsequently underwent linear accelerator (LINAC) radiosurgery. Two of the patients were cured, one exhibited a significant reduction in tumour size and the fourth remains stable. All four patients are alive and well. In cases of small residual tumours or recurrences radio-surgery allows open surgery to be avoided and is a safe and potentially effective approach. (author)

  19. The effects of pentoxifylline on the survival of human glioma cells with continuous and intermittent stereotactic radiosurgery irradiation

    International Nuclear Information System (INIS)

    Eley, Kerry W.; Benedict, Stanley H.; Chung, Theodore D.K.; Kavanagh, Brian D.; Broaddus, William C.; Schmidt-Ullrich, Rupert K.A.; Lin, P.-S.

    2002-01-01

    Purpose: In linac-based stereotactic radiosurgery, treatment is delivered intermittently via multiple individual small radiotherapy arcs. The time lapses between the individual arcs permit greater damage repair and increased tumor cell survival in comparison with continuous irradiation. Because pentoxifylline (PTX) has been reported to prevent radiation-induced cell cycle arrest at the G2/M checkpoint, where damage repair is critically linked to cell survival, we hypothesized that PTX would exert a favorable radiosensitization effect by reducing the recovery observed during intermittent stereotactic radiosurgery. Methods and Materials: The human glioma cell line T98G was used to study the effects of continuous vs. intermittent irradiation with or without PTX. Cell cycle patterns were studied using flow cytometry. Clonogenic assays of single cells and spheroid outgrowth assays provided a quantitative measure of PTX-mediated radiosensitization. The PTX effect upon cells in low oxygen conditions was also studied in vitro after enzymatic oxygen scavenging. Results: Flow Cytometry: T98G cells exposed to both continuous and intermittent irradiation exhibit similar arrest at the G2/M checkpoint. The addition of 2 mM PTX significantly reduced the radiation-induced G2/M block in both irradiation schemes. Clonogenic Assays: The same PTX concentration applied before a continuous dose of 12 Gy, two intermittent doses of 6 Gy, or three intermittent doses of 4 Gy, all given within a 1-h interval, consistently caused radiosensitization. The drug enhancement ratios for PTX were 1.5, 2.7, and 6.0 for the continuous and two different intermittent dose schedules, respectively. Adding PTX after irradiation yielded lower enhancement ratios than pre-irradiation application. A similar pattern was observed after total doses of 4, 6, 9, or 12 Gy, as well. In low oxygen conditions, PTX was seen to have the same effects as in normoxic conditions. Spheroid Outgrowth Assays: The in vitro PTX

  20. Gamma Knife® radiosurgery for trigeminal neuralgia.

    Science.gov (United States)

    Yen, Chun-Po; Schlesinger, David; Sheehan, Jason P

    2011-11-01

    Trigeminal neuralgia is characterized by a temporary paroxysmal lancinating facial pain in the trigeminal nerve distribution. The prevalence is four to five per 100,000. Local pressure on nerve fibers from vascular loops results in painful afferent discharge from an injured segment of the fifth cranial nerve. Microvascular decompression addresses the underlying pathophysiology of the disease, making this treatment the gold standard for medically refractory trigeminal neuralgia. In patients who cannot tolerate a surgical procedure, those in whom a vascular etiology cannot be identified, or those unwilling to undergo an open surgery, stereotactic radiosurgery is an appropriate alternative. The majority of patients with typical facial pain will achieve relief following radiosurgical treatment. Long-term follow-up for recurrence as well as for radiation-induced complications is required in all patients undergoing stereotactic radiosurgery for trigeminal neuralgia.

  1. Physics of gamma knife approach on convergent beams in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Wu, A.; Lindner, G.; Maitz, A.H.; Kalend, A.M.; Lunsford, L.D.; Flickinger, J.C.; Bloomer, W.D.

    1990-01-01

    The Presbyterian-University Hospital of Pittsburgh installed the first clinically designated Leksell gamma knife in the U.S. in August 1987. Gamma knife radiosurgery involves stereotactic target localization with the Leksell frame and subsequent closed-skull single-treatment session irradiation of a lesion with multiple highly focused gamma ray beams produced from 60Co sources. The hemispherical array of sources, the large number of small-diameter beams, and the steep dose gradients surrounding a targeted lesion make physical characterization of the radiation field complex. This paper describes the physical features and the operation of the gamma knife as well as the calibration procedures of the very small, well-collimated beams. The results of studies using in-phantom ion chamber, diode, film, and lithium fluoride thermoluminescent dosimetry were all in close agreement. Both single-beam and multiple-beam dose profiles were measured and reported for the interchangeable helmets, which have 4-, 8-, 14-, and 18-mm-diameter collimators. We also describe the dose calculation and treatment planning algorithm in the treatment planning system. Measurements of the accuracy of mechanical and radiation alignment are also performed and discussed

  2. Radiosurgery in gliomas (middle-line tumors)

    International Nuclear Information System (INIS)

    Betti, O.O.; Rosler, R.

    1989-01-01

    The clinical experience is presented obtained from treatment with high-energy linac radiosurgery of 22 patients with stereotactically biopsed gliomas located in middle-line, from thalamus to brain stem and from infundibulum to pineo-tectal regions, during the period 1982-1987. (H.W.). 10 refs

  3. Physics and radiobiology of heavy charged particles in relation to the use of ion beams for therapy

    International Nuclear Information System (INIS)

    Kraft, G.; Haberer, T.; Schardt, D.; Scholz, M.

    1993-07-01

    Heavy charged particles are the most advanced tool of an external subcutane radiotherapy of deep seated tumors. Small angular- and lateral-scattering and the increase of the energy deposition with penetration depth are the physical basis for a more efficient tumor targeting. High biological efficiency in the tumor is the prerequisite for a successful treatment of tumors radioresistant against sparsely ionizing radiation. The possibility to perform target conform irradiation and to control the achieved/actual distribution using PET techniques guarantees that biological highly efficient stepping particles can be restricted to the tumor volume only. Although the physical and radiobiological properties of ion beams are very favourable for therapy, the necessity to produce these particles in an accelerator restricts a general application of heavy ions up to now. Presently the heavy ion accelerator SIS at GSI is the only source of heavy ion beams, sufficient in energy and intensity for therapy. A therapy unit is in preparation at GSI, the status of this project is given at the end of the paper. (orig.)

  4. Contribution to the planning and dosimetry of photon beams applied to radiosurgery and stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Santos, Walter Menezes

    2003-08-01

    Radiosurgery and stereotactic radiotherapy are irradiation techniques that use small diameter photon beams for treating intracranial lesions such as pituitary adenomas, acoustic tumors and arterio-venous malformations which are inaccessible for surgery. These treatment techniques are characterized by the use of very small radiation beams which deliver a precisely measured dose to the target volume, while sparing the surrounding healthy tissue. Treatment can be performed by using multiple 60 Co gamma-ray sources (in the so-called 'Gamma Knife'), charged particles or X-ray beams produced by linear accelerators. The prescribed dose can be given in a single session or in multiple fractions, as in conventional radiotherapy. The success of the treatment depends, among other factors, of the accurate determination of the parameters that characterize the radiation beam produced by the equipment, as well as, of a well designed quality assurance program. In this study, the dosimetric parameters of a set of collimating cones of a Radionics TM treatment system applied to two 6 MV- photon beams (Clinac 600C - Varian TM , and Mevatron MD2 - Siemens TM ) were evaluated by using a water filled PMMA simulator. Measurements were carried out for photon beam diameters ranging from 12.5 to 40.0 mm for the Clinac-600C and from 5.0 to 50.0 mm for the Mevatron MD2. The parameters were evaluated by using a parallel plate ionization chamber (Markus), Kodak X-Omat V dosimetric films, thermoluminescent dosemeters (Harschaw, TLD-100) and photodiodes. The maximum tissue-ratio, the off-axis profile and the output factors were determined and the results were compared to those reported elsewhere. A study of the dosimetric characteristics of some commercially available phototransistors was also carried out. The results showed that these electronic components can be successfully used for measuring the dosimetric parameters of small diameter photon beans used in radiosurgery. Measurements were also

  5. Linear accelerator stereotactic radiosurgery for vestibular schwannomas: a UK series.

    Science.gov (United States)

    Benghiat, H; Heyes, G; Nightingale, P; Hartley, A; Tiffany, M; Spooner, D; Geh, J I; Cruickshank, G; Irving, R M; Sanghera, P

    2014-06-01

    To evaluate non-auditory toxicity and local control after linear accelerator stereotactic radiosurgery (SRS) for the treatment of vestibular schwannomas. The institutional policy was to use SRS for radiologically progressing vestibular schwannomas. Case notes and plans were retrospectively reviewed for all patients undergoing SRS for vestibular schwannomas between September 2002 and June 2012. All patients were surgically immobilised using a BrainLab stereotactic head frame. The treatment plan was generated using BrainLab software (BrainScan 5.03). The aim was to deliver 12 Gy to the surface of the target with no margin. Patients with a minimum of 12 months of follow-up were included for toxicity and local control assessment. Radiological progression was defined as growth on imaging beyond 2 years of follow-up. Overall local control was defined in line with other series as absence of surgical salvage. Ninety-nine patients were identified. Two patients were lost to follow-up. After a median follow-up interval of 2.4 years, the actuarial radiological progression-free survival at 3 years was 100% and overall local control was also 100%. However, two patients progressed radiologically at 3.3 and 4.5 years, respectively. Twenty-one of 97 (22%) evaluable patients suffered trigeminal toxicity and this was persistent in 8/97 (8%). Two of 97 (2%) suffered long-term facial nerve toxicity (one with associated radiological progression causing hemi-facial spasm alone). One of 97 (1%) required intervention for obstructive hydrocephalus. No statistically significant dosimetric relationship could be shown to cause trigeminal or facial nerve toxicity. However, 7/8 patients with persistent trigeminal nerve toxicity had tumours in contact with the trigeminal nerve. SRS delivering 12 Gy using a linear accelerator leads to high local control rates, but only prospective evaluation will fully establish short-term toxicity. In this study, persistent trigeminal toxicity occurred almost

  6. Mass and charge distribution in heavy-ion collisions

    International Nuclear Information System (INIS)

    Beck, F.; Dworzecka, M.; Feldmeier, H.

    1978-01-01

    A statistical model based on the independent particle picture is used to calculate mass and charge distributions in deep inelastic heavy-ion collisions. Different assumptions on volume and charge equilibrations are compared with measured variances of charge distributions. One combination of assumptions is clearly favoured by experiment, and gives a reasonable description of the variance versus energy loss curves up to energy losses of about 200 MeV in the heavy systems Kr+Ho and Xe+Bi, and up to about 60 MeV for the light system Ar+Ca [af

  7. State-of-the-art treatment alternatives for base of skull meningiomas: complementing and controversial indications for neurosurgery, stereotactic and robotic based radiosurgery or modern fractionated radiation techniques

    International Nuclear Information System (INIS)

    Combs, Stephanie E; Ganswindt, Ute; Foote, Robert L; Kondziolka, Douglas; Tonn, Jörg-Christian

    2012-01-01

    For skull base meningiomas, several treatment paradigms are available: Observation with serial imaging, surgical resection, stereotactic radiosurgery, radiation therapy or some combination of both. The choice depends on several factors. In this review we evaluate different treatment options, the outcome of modern irradiation techniques as well as the clinical results available, and establish recommendations for the treatment of patients with skull-base meningiomas

  8. Dose linearity and monitor unit stability of a G4 type cyberknife robotic stereotactic radiosurgery system

    International Nuclear Information System (INIS)

    Sudahar, H.; Kurup, P.G.G.; Murali, V.; Velmurugan, J.

    2012-01-01

    Dose linearity studies on conventional linear accelerators show a linearity error at low monitor units (MUs). The purpose of this study was to establish the dose linearity and MU stability characteristics of a cyberknife (Accuracy Inc., USA) stereotactic radiosurgery system. Measurements were done at a depth of 5 cm in a stereotactic dose verification phantom with a source to surface distance of 75 cm in a Generation 4 (G4) type cyberknife system. All the 12 fixed-type collimators starting from 5 to 60 mm were used for the dose linearity study. The dose linearity was examined in small (1-10), medium (15-100) and large (125-1000) MU ranges. The MU stability test was performed with 60 mm collimator for 10 MU and 20 MU with different combinations. The maximum dose linearity error of -38.8% was observed for 1 MU with 5 mm collimator. Dose linearity error in the small MU range was considerably higher than in the medium and large MU ranges. The maximum error in the medium range was -2.4%. In the large MU range, the linearity error varied between -0.7% and 1.2%. The maximum deviation in the MU stability was -3.03%. (author)

  9. Response of radiochromic dye films to low energy heavy charged particles

    CERN Document Server

    Buenfil, A E; Gamboa-Debuen, I; Aviles, P; Avila, O; Olvera, C; Robledo, R; Rodriguez-Ponce, M; Mercado-Uribe, H; Rodriguez-Villafuerte, M; Brandan, M E

    2002-01-01

    We have studied the possible use of radiochromic dye films (RCF) as heavy charged particle dosemeters. We present the results of irradiating two commercial RCF (GafChromic HD-810 and MD-55-1) with 1.5, 2.9 and 4.4 MeV protons, 1.4, 2.8, 4.7, 5.9, 6.8 MeV sup 4 He ions and 8.5 and 12.4 MeV sup 1 sup 2 C ions, at proton doses from about 1 Gy up to 3 kGy, helium ions doses from 3 Gy to 5 kGy and carbon ion doses from 30 Gy to 20 kGy. The films were scanned and digitized using commercial equipment. For a given particle, the response per unit dose at different energies indicates an energy dependence of the sensitivity, which is discussed. Comparison was made for the use of a standard spectrophotometer to obtain optical density readings versus a white light scanner.

  10. Optimal technique of linear accelerator–based stereotactic radiosurgery for tumors adjacent to brainstem

    International Nuclear Information System (INIS)

    Chang, Chiou-Shiung; Hwang, Jing-Min; Tai, Po-An; Chang, You-Kang; Wang, Yu-Nong; Shih, Rompin; Chuang, Keh-Shih

    2016-01-01

    Stereotactic radiosurgery (SRS) is a well-established technique that is replacing whole-brain irradiation in the treatment of intracranial lesions, which leads to better preservation of brain functions, and therefore a better quality of life for the patient. There are several available forms of linear accelerator (LINAC)–based SRS, and the goal of the present study is to identify which of these techniques is best (as evaluated by dosimetric outcomes statistically) when the target is located adjacent to brainstem. We collected the records of 17 patients with lesions close to the brainstem who had previously been treated with single-fraction radiosurgery. In all, 5 different lesion catalogs were collected, and the patients were divided into 2 distance groups—1 consisting of 7 patients with a target-to-brainstem distance of less than 0.5 cm, and the other of 10 patients with a target-to-brainstem distance of ≥ 0.5 and < 1 cm. Comparison was then made among the following 3 types of LINAC-based radiosurgery: dynamic conformal arcs (DCA), intensity-modulated radiosurgery (IMRS), and volumetric modulated arc radiotherapy (VMAT). All techniques included multiple noncoplanar beams or arcs with or without intensity-modulated delivery. The volume of gross tumor volume (GTV) ranged from 0.2 cm 3 to 21.9 cm 3 . Regarding the dose homogeneity index (HI ICRU ) and conformity index (CI ICRU ) were without significant difference between techniques statistically. However, the average CI ICRU = 1.09 ± 0.56 achieved by VMAT was the best of the 3 techniques. Moreover, notable improvement in gradient index (GI) was observed when VMAT was used (0.74 ± 0.13), and this result was significantly better than those achieved by the 2 other techniques (p < 0.05). For V 4 Gy of brainstem, both VMAT (2.5%) and IMRS (2.7%) were significantly lower than DCA (4.9%), both at the p < 0.05 level. Regarding V 2 Gy of normal brain, VMAT plans had attained 6.4 ± 5%; this was significantly better

  11. Implementation of a lung radiosurgery program: technical considerations and quality assurance in an Australian institution

    International Nuclear Information System (INIS)

    Siva, Shankar; MacManus, Michael; Ball, David; Chesson, Brent; Aarons, Yolanda; Clements, Natalie; Kron, Tomas

    2012-01-01

    The Peter MacCallum Cancer Centre has established a stereotactic lung radiosurgery program for the treatment of isolated lung metastases. The aim of this study was to critically assess the technical feasibility of performing stereotactic lung radiosurgery in an Australian institution. A single 26-Gy fraction of radiotherapy was delivered to patients with positron emission tomography (PET) staged solitary lung metastases. Motion management was addressed using four-dimensional computed tomographic simulation, and cone beam CT (CBCT) online soft-tissue matching. Treatments were with multiple coplanar and non-coplanar asymmetric beams. Patients were immobilised in a dedicated stereotactic body cradle. Quality assurance (QA) of treatment plans with both ion chamber and film measurements was performed accounting for patient-specific respiratory motion. Between February 2010 and February 2011, nine patients received stereotactic lung radiosurgery. One grade 1 toxicity and one grade 2 toxicity were recorded after treatment. The mean planning target volume was 22.6 cc. A median of eight beams were delivered per treatment plan (range 7–10) with a median of two non-coplanar beams (range 0–6). At treatment plan QA, the difference between planned and delivered dose was ≤1.76% in all static and dynamic ion chamber recordings. A mid-treatment CBCT was performed at a median time of 21 min, with the mean displacement discrepancy from initial set-up being 0.4 mm (range 0–2 mm). Stereotactic radiosurgery to the lung was both feasible and tolerable at our institution. Intrafractional immobilisation within 2 mm was reproducible. Excellent concordance between planned and delivered treatments was achieved in the phantom QA.

  12. Evaluations of the setup discrepancy between BrainLAB 6D ExacTrac and cone-beam computed tomography used with the imaging guidance system Novalis-Tx for intracranial stereotactic radiosurgery.

    Science.gov (United States)

    Oh, Se An; Park, Jae Won; Yea, Ji Woon; Kim, Sung Kyu

    2017-01-01

    The objective of this study was to evaluate the setup discrepancy between BrainLAB 6 degree-of-freedom (6D) ExacTrac and cone-beam computed tomography (CBCT) used with the imaging guidance system Novalis Tx for intracranial stereotactic radiosurgery. We included 107 consecutive patients for whom white stereotactic head frame masks (R408; Clarity Medical Products, Newark, OH) were used to fix the head during intracranial stereotactic radiosurgery, between August 2012 and July 2016. The patients were immobilized in the same state for both the verification image using 6D ExacTrac and online 3D CBCT. In addition, after radiation treatment, registration between the computed tomography simulation images and the CBCT images was performed with offline 6D fusion in an offline review. The root-mean-square of the difference in the translational dimensions between the ExacTrac system and CBCT was <1.01 mm for online matching and <1.10 mm for offline matching. Furthermore, the root-mean-square of the difference in the rotational dimensions between the ExacTrac system and the CBCT were <0.82° for online matching and <0.95° for offline matching. It was concluded that while the discrepancies in residual setup errors between the ExacTrac 6D X-ray and the CBCT were minor, they should not be ignored.

  13. Stereotactic Radiosurgery for Recurrent or Unresectable Pilocytic Astrocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Hallemeier, Christopher L. [Department of Radiation Oncology, Mayo Clinic, Rochester, MN (United States); Pollock, Bruce E. [Department of Radiation Oncology, Mayo Clinic, Rochester, MN (United States); Department of Neurological Surgery, Mayo Clinic, Rochester, MN (United States); Schomberg, Paula J. [Department of Radiation Oncology, Mayo Clinic, Rochester, MN (United States); Link, Michael J. [Department of Neurological Surgery, Mayo Clinic, Rochester, MN (United States); Brown, Paul D. [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Stafford, Scott L., E-mail: Stafford.scott@mayo.edu [Department of Radiation Oncology, Mayo Clinic, Rochester, MN (United States)

    2012-05-01

    Purpose: To report the outcomes in patients with recurrent or unresectable pilocytic astrocytoma (PA) treated with Gamma Knife stereotactic radiosurgery (SRS). Methods and Materials: Retrospective review of 18 patients (20 lesions) with biopsy-confirmed PA having SRS at our institution from 1992 through 2005. Results: The median patient age at SRS was 23 years (range, 4-56). Thirteen patients (72%) had undergone one or more previous surgical resections, and 10 (56%) had previously received external-beam radiation therapy (EBRT). The median SRS treatment volume was 9.1 cm{sup 3} (range, 0.7-26.7). The median tumor margin dose was 15 Gy (range, 12-20). The median follow-up was 8.0 years (range, 0.5-15). Overall survival at 1, 5, and 10 years after SRS was 94%, 71%, and 71%, respectively. Tumor progression (local solid progression, n = 4; local solid progression + distant, n = 1; distant, n = 2; cyst development/progression, n = 4) was noted in 11 patients (61%). Progression-free survival at 1, 5, and 10 years was 65%, 41%, and 17%, respectively. Prior EBRT was associated with inferior overall survival (5-year risk, 100% vs. 50%, p = 0.03) and progression-free survival (5-year risk, 71% vs. 20%, p = 0.008). Nine of 11 patients with tumor-related symptoms improved after SRS. Symptomatic edema after SRS occurred in 8 patients (44%), which resolved with short-term corticosteroid therapy in the majority of those without early disease progression. Conclusions: SRS has low permanent radiation-related morbidity and durable local tumor control, making it a meaningful treatment option for patients with recurrent or unresectable PA in whom surgery and/or EBRT has failed.

  14. Stereotactic Radiosurgery for Recurrent or Unresectable Pilocytic Astrocytoma

    International Nuclear Information System (INIS)

    Hallemeier, Christopher L.; Pollock, Bruce E.; Schomberg, Paula J.; Link, Michael J.; Brown, Paul D.; Stafford, Scott L.

    2012-01-01

    Purpose: To report the outcomes in patients with recurrent or unresectable pilocytic astrocytoma (PA) treated with Gamma Knife stereotactic radiosurgery (SRS). Methods and Materials: Retrospective review of 18 patients (20 lesions) with biopsy-confirmed PA having SRS at our institution from 1992 through 2005. Results: The median patient age at SRS was 23 years (range, 4–56). Thirteen patients (72%) had undergone one or more previous surgical resections, and 10 (56%) had previously received external-beam radiation therapy (EBRT). The median SRS treatment volume was 9.1 cm 3 (range, 0.7–26.7). The median tumor margin dose was 15 Gy (range, 12–20). The median follow-up was 8.0 years (range, 0.5–15). Overall survival at 1, 5, and 10 years after SRS was 94%, 71%, and 71%, respectively. Tumor progression (local solid progression, n = 4; local solid progression + distant, n = 1; distant, n = 2; cyst development/progression, n = 4) was noted in 11 patients (61%). Progression-free survival at 1, 5, and 10 years was 65%, 41%, and 17%, respectively. Prior EBRT was associated with inferior overall survival (5-year risk, 100% vs. 50%, p = 0.03) and progression-free survival (5-year risk, 71% vs. 20%, p = 0.008). Nine of 11 patients with tumor-related symptoms improved after SRS. Symptomatic edema after SRS occurred in 8 patients (44%), which resolved with short-term corticosteroid therapy in the majority of those without early disease progression. Conclusions: SRS has low permanent radiation-related morbidity and durable local tumor control, making it a meaningful treatment option for patients with recurrent or unresectable PA in whom surgery and/or EBRT has failed.

  15. Multistage stereotactic radiosurgery for large cerebral arteriovenous malformations using the Gamma Knife platform.

    Science.gov (United States)

    Ding, Chuxiong; Hrycushko, Brian; Whitworth, Louis; Li, Xiang; Nedzi, Lucien; Weprin, Bradley; Abdulrahman, Ramzi; Welch, Babu; Jiang, Steve B; Wardak, Zabi; Timmerman, Robert D

    2017-10-01

    Radiosurgery is an established technique to treat cerebral arteriovenous malformations (AVMs). Obliteration of larger AVMs (> 10-15 cm 3 or diameter > 3 cm) in a single session is challenging with current radiosurgery platforms due to toxicity. We present a novel technique of multistage stereotactic radiosurgery (SRS) for large intracranial arteriovenous malformations (AVM) using the Gamma Knife system. Eighteen patients with large (> 10-15 cm 3 or diameter > 3 cm) AVMs, which were previously treated using a staged SRS technique on the Cyberknife platform, were retrospectively selected for this study. The AVMs were contoured and divided into 3-8 subtargets to be treated sequentially in a staged approach at half to 4 week intervals. The prescription dose ranged from 15 Gy to 20 Gy, depending on the subtarget number, volume, and location. Gamma Knife plans using multiple collimator settings were generated and optimized. The coordinates of each shot from the initial plan covering the total AVM target were extracted based on their relative positions within the frame system. The shots were regrouped based on their location with respect to the subtarget contours to generate subplans for each stage. The delivery time of each shot for a subtarget was decay corrected with 60 Co for staging the treatment course to generate the same dose distribution as that planned for the total AVM target. Conformality indices and dose-volume analysis were performed to evaluate treatment plans. With the shot redistribution technique, the composite dose for the multistaged treatment of multiple subtargets is equivalent to the initial plan for total AVM target. Gamma Knife plans resulted in an average PTV coverage of 96.3 ± 0.9% and a PITV of 1.23 ± 0.1. The resulting Conformality indices, V 12Gy and R 50 dose spillage values were 0.76 ± 0.05, 3.4 ± 1.8, and 3.1 ± 0.5 respectively. The Gamma Knife system can deliver a multistaged conformal dose to treat large AVMs when correcting for

  16. Multi-staged robotic stereotactic radiosurgery for large cerebral arteriovenous malformations

    International Nuclear Information System (INIS)

    Ding, Chuxiong; Solberg, Timothy D.; Hrycushko, Brian; Medin, Paul; Whitworth, Louis; Timmerman, Robert D.

    2013-01-01

    Purpose: To investigate a multi-staged robotic stereotactic radiosurgery (SRS) delivery technique for the treatment of large cerebral arteriovenous malformations (AVMs). The treatment planning process and strategies to optimize both individual and composite dosimetry are discussed. Methods: Eleven patients with large (30.7 ± 19.2 cm 3 ) AVMs were selected for this study. A fiducial system was designed for fusion of targets between planar angiograms and simulation CT scans. AVMs were contoured based on single contrast CT, MRI and orthogonal angiogram images. AVMs were divided into 3–8 sub-target volumes (3–7 cm 3 ) for sequential treatment at 1–4 week intervals to a prescription dose of 16–20 Gy. Forward and inversely developed treatment plans were optimized for 95% coverage of the total AVM volume by dose summation from each sub-volume, while minimizing dose to surrounding tissues. Dose-volume analysis was used to evaluate the PTV coverage, dose conformality (CI), and R 50 and V 12Gy parameters. Results: The treatment workflow was commissioned and able to localize within 1 mm. Inverse optimization outperformed forward planning for most patients for each index considered. Dose conformality was shown comparable to staged Gamma Knife treatments. Conclusion: The CyberKnife system is shown to be a practical delivery platform for multi-staged treatments of large AVMs using forward or inverse planning techniques

  17. Dosimetric verification of stereotactic radiosurgery/stereotactic radiotherapy dose distributions using Gafchromic EBT3

    Energy Technology Data Exchange (ETDEWEB)

    Cusumano, Davide, E-mail: davide.cusumano@unimi.it [School of Medical Physics, University of Milan, Milan (Italy); Fumagalli, Maria L. [Health Department, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan (Italy); Marchetti, Marcello; Fariselli, Laura [Department of Neurosurgery, Radiotherapy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan (Italy); De Martin, Elena [Health Department, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan (Italy)

    2015-10-01

    Aim of this study is to examine the feasibility of using the new Gafchromic EBT3 film in a high-dose stereotactic radiosurgery and radiotherapy quality assurance procedure. Owing to the reduced dimensions of the involved lesions, the feasibility of scanning plan verification films on the scanner plate area with the best uniformity rather than using a correction mask was evaluated. For this purpose, signal values dispersion and reproducibility of film scans were investigated. Uniformity was then quantified in the selected area and was found to be within 1.5% for doses up to 8 Gy. A high-dose threshold level for analyses using this procedure was established evaluating the sensitivity of the irradiated films. Sensitivity was found to be of the order of centiGray for doses up to 6.2 Gy and decreasing for higher doses. The obtained results were used to implement a procedure comparing dose distributions delivered with a CyberKnife system to planned ones. The procedure was validated through single beam irradiation on a Gafchromic film. The agreement between dose distributions was then evaluated for 13 patients (brain lesions, 5 Gy/die prescription isodose ~80%) using gamma analysis. Results obtained using Gamma test criteria of 5%/1 mm show a pass rate of 94.3%. Gamma frequency parameters calculation for EBT3 films showed to strongly depend on subtraction of unexposed film pixel values from irradiated ones. In the framework of the described dosimetric procedure, EBT3 films proved to be effective in the verification of high doses delivered to lesions with complex shapes and adjacent to organs at risk.

  18. Extracranial stereotactic radiotherapy: preliminary results with the CyberKnife.

    Science.gov (United States)

    Lartigau, Eric; Mirabel, Xavier; Prevost, Bernard; Lacornerie, Thomas; Dubus, Francois; Sarrazin, Thierry

    2009-04-01

    In the field of radiation oncology, equipment for fractionated radiotherapy and single-dose radiosurgery has become increasingly accurate, together with the introduction of robotized treatments. A robot is a device that can be programmed to carry out accurate, repeated and adjusted tasks in a given environment. Treatment of extracranial lesions involves taking into account organ mobility (tumor and healthy tissue) whilst retaining the ability to stereotactically locate the target. New imaging techniques (single-photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), positron emission tomography (PET)) provide further relevant information to slice images (computed tomography (CT) scans, MRI) for target definition. Hypo-fractionated treatments can only be used for curative treatment if the target is accurately defined and tracked during treatment. The CyberKnife is a non-invasive system of radiosurgery and fractionated stereotactic radiotherapy. For intracranial lesions treated by single-dose radiosurgery, it has been used to treat meningioma, acoustic neuromas, pituitary adenoma, metastases, arteriovenous malformations and refractory pain (trigeminal neuralgia). More than 10,000 patients have been treated worldwide. Currently, the most significant developments are in the field of extracranial stereotactic radiotherapy (lung, liver, reirradiation, prostate, etc.). Clinical results obtained in the CyberKnife Nord-Ouest program after 1 year of experience are presented. Copyright 2009 S. Karger AG, Basel.

  19. Treatment of acoustic neuroma: stereotactic radiosurgery vs. microsurgery

    International Nuclear Information System (INIS)

    Karpinos, Marianna; Teh, Bin S.; Zeck, Otto; Carpenter, L. Steven; Phan, Chris; Mai, W.-Y.; Lu, Hsin H.; Chiu, J. Kam; Butler, E. Brian; Gormley, William B.; Woo, Shiao Y.

    2002-01-01

    Purpose: Two major treatment options are available for patients with acoustic neuroma, microsurgery and radiosurgery. Our objective was to compare these two treatment modalities with respect to tumor growth control, hearing preservation, development of cranial neuropathies, complications, functional outcome, and patient satisfaction. Methods and Materials: To compare radiosurgery with microsurgery, we analyzed 96 patients with unilateral acoustic neuromas treated with Leksell Gamma Knife or microsurgery at Memorial Hermann Hospital, Houston, Texas, between 1993 and 2000. Radiosurgery technique involved multiple isocenter (1-30 single fraction fixed-frame magnetic resonance imaging) image-based treatment with a mean dose prescription of 14.5 Gy. Microsurgery included translabyrinthine, suboccipital, and middle fossa approaches with intraoperative neurophysiologic monitoring. Preoperative patient characteristics were similar except for tumor size and age. Patients undergoing microsurgery were younger with larger tumors compared to the radiosurgical group. The tumors were divided into small 4.0 cm. Median follow-up of the radiosurgical group was longer than the microsurgical group, 48 months (3-84 months) vs. 24 months (3-72 months). Results: There was no statistical significance in tumor growth control between the two groups, 100% in the microsurgery group vs. 91% in the radiosurgery group (p>0.05). Radiosurgery was more effective than microsurgery in measurable hearing preservation, 57.5% vs. 14.4% (p=0.01). There was no difference in serviceable hearing preservation between the two groups. Microsurgery was associated with a greater rate of facial and trigeminal neuropathy in the immediate postoperative period and at long-term follow-up. The rate of development of facial neuropathy was significantly higher in the microsurgical group than in the radiosurgical group (35% vs. 0%, p<0.01 in the immediate postsurgical period and 35.3% vs. 6.1%, p=0.008, at long

  20. Treatment of acoustic neuroma: stereotactic radiosurgery vs. microsurgery

    Energy Technology Data Exchange (ETDEWEB)

    Karpinos, Marianna; Teh, Bin S; Zeck, Otto; Carpenter, L Steven; Phan, Chris; Mai, W -Y; Lu, Hsin H; Chiu, J Kam; Butler, E Brian; Gormley, William B; Woo, Shiao Y

    2002-12-01

    Purpose: Two major treatment options are available for patients with acoustic neuroma, microsurgery and radiosurgery. Our objective was to compare these two treatment modalities with respect to tumor growth control, hearing preservation, development of cranial neuropathies, complications, functional outcome, and patient satisfaction. Methods and Materials: To compare radiosurgery with microsurgery, we analyzed 96 patients with unilateral acoustic neuromas treated with Leksell Gamma Knife or microsurgery at Memorial Hermann Hospital, Houston, Texas, between 1993 and 2000. Radiosurgery technique involved multiple isocenter (1-30 single fraction fixed-frame magnetic resonance imaging) image-based treatment with a mean dose prescription of 14.5 Gy. Microsurgery included translabyrinthine, suboccipital, and middle fossa approaches with intraoperative neurophysiologic monitoring. Preoperative patient characteristics were similar except for tumor size and age. Patients undergoing microsurgery were younger with larger tumors compared to the radiosurgical group. The tumors were divided into small <2.0 cm, medium 2.0-3.9 cm, or large >4.0 cm. Median follow-up of the radiosurgical group was longer than the microsurgical group, 48 months (3-84 months) vs. 24 months (3-72 months). Results: There was no statistical significance in tumor growth control between the two groups, 100% in the microsurgery group vs. 91% in the radiosurgery group (p>0.05). Radiosurgery was more effective than microsurgery in measurable hearing preservation, 57.5% vs. 14.4% (p=0.01). There was no difference in serviceable hearing preservation between the two groups. Microsurgery was associated with a greater rate of facial and trigeminal neuropathy in the immediate postoperative period and at long-term follow-up. The rate of development of facial neuropathy was significantly higher in the microsurgical group than in the radiosurgical group (35% vs. 0%, p<0.01 in the immediate postsurgical period and 35

  1. Dosimetric measurements of Onyx embolization material for stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Roberts, Donald A.; Balter, James M.; Chaudhary, Neeraj; Gemmete, Joseph J.; Pandey, Aditya S.

    2012-01-01

    Purpose: Arteriovenous malformations are often treated with a combination of embolization and stereotactic radiosurgery. Concern has been expressed in the past regarding the dosimetric properties of materials used in embolization and the effects that the introduction of these materials into the brain may have on the quality of the radiosurgery plan. To quantify these effects, the authors have taken large volumes of Onyx 34 and Onyx 18 (ethylene-vinyl alcohol copolymer doped with tantalum) and measured the attenuation and interface effects of these embolization materials. Methods: The manufacturer provided large cured volumes (∼28 cc) of both Onyx materials. These samples were 8.5 cm in diameter with a nominal thickness of 5 mm. The samples were placed on a block tray above a stack of solid water with an Attix chamber at a depth of 5 cm within the stack. The Attix chamber was used to measure the attenuation. These measurements were made for both 6 and 16 MV beams. Placing the sample directly on the solid water stack and varying the thickness of solid water between the sample and the Attix chamber measured the interface effects. The computed tomography (CT) numbers for bulk material were measured in a phantom using a wide bore CT scanner. Results: The transmission through the Onyx materials relative to solid water was approximately 98% and 97% for 16 and 6 MV beams, respectively. The interface effect shows an enhancement of approximately 2% and 1% downstream for 16 and 6 MV beams. CT numbers of approximately 2600–3000 were measured for both materials, which corresponded to an apparent relative electron density (RED) ρ e w to water of approximately 2.7–2.9 if calculated from the commissioning data of the CT scanner. Conclusions: We performed direct measurements of attenuation and interface effects of Onyx 34 and Onyx 18 embolization materials with large samples. The introduction of embolization materials affects the dose distribution of a MV therapeutic beam

  2. Awake craniotomy for excision of arteriovenous malformations? A qualitative comparison study with stereotactic radiosurgery.

    Science.gov (United States)

    Chan, David Yuen Chung; Chan, Danny Tat Ming; Zhu, Cannon Xian Lun; Kan, Patricia Kwok Yee; Ng, Amelia Yikjin; Hsieh, Yi-Pin Sonia; Abrigo, Jill; Poon, Wai Sang; Wong, George Kwok Chu

    2018-05-01

    Treatment of arteriovenous malformations (AVM) located at the eloquent area has been a challenge. Awake brain mapping allows identification of a non-eloquent gyrus for intervention and can potentially facilitate resection with preservation of functions. An alternative treatment option is stereotactic radiosurgery (SRS). The objective of this study was to perform a qualitative comparison of the treatment outcome of awake AVM excision versus SRS. We conducted a 13-year retrospective review of AVM excision under awake craniotomy performed at Prince of Wales Hospital, Hong Kong, from 2003 to 2016. Patients' presentation, Spetzler-Martin (SM) grading, rate of obliteration and complication were reviewed and analyzed with the modified radiosurgery-based AVM score (RS score). Six patients had excision of AVM under awake mapping during this period of time. Two were SM Grade II and four were SM Grade III. Five located at the peri-rolandic region while one at the temporal language area. None had failed mapping. Five out of six achieved complete obliteration (83.3%). Qualitative comparative analysis had revealed better treatment outcome with awake AVM excision as compared to SRS with the obliteration rate of 100% versus 96% for RS score ≤1.00, 100% versus 78% for RS score 1.01-1.50, and 66% versus 50% for RS score >2.00 respectively. In conclusion, awake mapping and excision of AVMs at the eloquent area is feasible. Qualitative comparative analysis had revealed higher obliteration rate with awake AVM excision as compared to SRS. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Clinical Experiences With Onboard Imager KV Images for Linear Accelerator-Based Stereotactic Radiosurgery and Radiotherapy Setup

    International Nuclear Information System (INIS)

    Hong, Linda X.; Chen, Chin C.; Garg, Madhur; Yaparpalvi, Ravindra; Mah, Dennis

    2009-01-01

    Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after treatment for 21 SRS patients and on a weekly basis for 6 SRT patients to assess any intrafraction changes. Results: For SRS patients, 57 pretreatment kV images were evaluated and the suggested shifts were all within 1 mm in any direction (i.e., within the accuracy of image fusion). For SRT patients, the suggested shifts were out of the 3-mm tolerance for 31 of 309 setups. Intrafraction motions were detected in 3 SRT patients. Conclusions: kV imaging provided a useful tool for SRS or SRT setups. For SRS setup with head frame, it provides radiographic confirmation of localization using the stereotactic target positioner. For SRT with mask, a 3-mm margin is adequate and feasible for routine setup when TaPo is combined with kV imaging

  4. Stereotactic radiotherapy for brain metastasis

    International Nuclear Information System (INIS)

    Noel, G.; Daisne, J.F.; Thillays, F.

    2012-01-01

    Stereotactic radiosurgery is now well implanted in the radiotherapy treatment tools of brain metastasis. The dose can be delivered in one or multiple sessions. Results seem equivalent. CT scan and MRI imaging are required to delineate and calculate dosimetry. Doses are variable according to the size of the metastases, localization, pathology or equipment. Stabilization or reduction of tumour size is the rules after stereotactic treatment. Impact in terms of overall survival is more difficult to apprehend because of the general context of the disease. Many questions remain unresolved, such as the usefulness of whole brain irradiation, adaptation of the treatment schedule to tumour pathophysiology, role of stereotactic treatment after surgery of metastases, etc. (authors)

  5. Stereotactic radiosurgery for deep intracranial arteriovenous malformations, part 1: Brainstem arteriovenous malformations.

    Science.gov (United States)

    Cohen-Inbar, Or; Ding, Dale; Chen, Ching-Jen; Sheehan, Jason P

    2016-02-01

    The management of brainstem arteriovenous malformations (AVM) are one of the greatest challenges encountered by neurosurgeons. Brainstem AVM have a higher risk of hemorrhage compared to AVM in other locations, and rupture of these lesions commonly results in devastating neurological morbidity and mortality. The potential morbidity associated with currently available treatment modalities further compounds the complexity of decision making for affected patients. Stereotactic radiosurgery (SRS) has an important role in the management of brainstem AVM. SRS offers acceptable obliteration rates with lower risks of hemorrhage occurring during the latency period. Complex nidal architecture requires a multi-disciplinary treatment approach. Nidi partly involving subpial/epipial regions of the dorsal midbrain or cerebellopontine angle should be considered for a combination of endovascular embolization, micro-surgical resection and SRS. Considering the fact that incompletely obliterated lesions (even when reduced in size) could still cause lethal hemorrhages, additional treatment, including repeat SRS and surgical resection should be considered when complete obliteration is not achieved by first SRS. Patients with brainstem AVM require continued clinical and radiological observation and follow-up after SRS, well after angiographic obliteration has been confirmed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Inner shell coulomb ionization by heavy charged particles studied by the SCA model

    International Nuclear Information System (INIS)

    Hansteen, J.M.

    1976-06-01

    An outline is given of the development of and some achievements hitherto gained from the semi-classical approximation (SCA) model of atomic Coulomb excitation by heavy charged particles. A few very recent results (1975-1976) are incorporated in the discussion. The SCA model has by now reached a mature state. Hence it seems reasonable to regard the atomic Coulomb excitation phenomenon as part of the extremely complicated excitation mechanism operative in the general ion-atom collision. A clear understanding of the complicated X-ray producing mechanisms in heavy-ion-atom collisions is lacking at present. Despite these facts, the conceptually simple SCA model has furthered our understanding far beyond initial expectations. Moreover, this model has at the same time provided a well-founded starting point for continued researches in this rapidly expanding field of physics. (JIW)

  7. Stereotactic lesioning for mental illness

    International Nuclear Information System (INIS)

    Kim, M.-C.; Lee, T.-K.

    2008-01-01

    The authors report stereotactically created lesioning by radiofrequency or Cyberknife radiosurgery for patients with mental illness. Since 1993, thirty-eight patients have undergone stereotactic psychosurgery for medically intractable mental illnesses. Two patients had aggressive behavior. Twenty-five patients suffered from Obsessive-Compulsive Disorder (OCD) and ten patients had depression. Another patient suffered from atypical psychosis. Bilateral amygdalotomy and subcaudate tractotomy were done for aggressive behavior. Limbic leucotomy or anterior cingulotomy was done for CCD and subcaudate tractotomy with or without cingulotomy was done for depression. In twenty-three patients, the lesions were made by a radiofrequency (RF) lesion generator. In fifteen cases, the lesions were made with Cyberknife Radiosurgery (CKRS). The Overt Aggression Scale (OAS) declined from 8 to 2 with clinical improvement during follow up period. With long-term follow up (meaning 57 months) in 25 OCDs, the mean Yale Brown Obsessive Compulsive Score (YBOCS) declined from 34 to 13 (n = 25). The Hamilton Depression scale (HAMD) for ten patients with depression declined from 38.5 to 10.5 (n = 10). There was no operative mortality and no significant morbidity except one case with transient urinary incontinence. Authors suggest that stereotactic psychosurgery by RF and CKRS could be a safe and effective means of treating some medically intractable mental illnesses. (author)

  8. Stereotactic intracranial radiotherapy: Dose prescription

    International Nuclear Information System (INIS)

    Schlienger, M.; Lartigau, E.; Nataf, F.; Mornex, F.; Latorzeff, I.; Lisbona, A.; Mahe, M.

    2012-01-01

    The aim of this article was the study of the successive steps permitting the prescription of dose in stereotactic intracranial radiotherapy, which includes radiosurgery and fractionated stereotactic radiotherapy. The successive steps studied are: the choice of stereotactic intracranial radiotherapy among the therapeutic options, based on curative or palliative treatment intent, then the selection of lesions according to size/volume, pathological type and their number permitting the choice between radiosurgery or fractionated stereotactic radiotherapy, which have the same methodological basis. Clinical experience has determined the level of dose to treat the lesions and limit the irradiation of healthy adjacent tissues and organs at risk structures. The last step is the optimization of the different parameters to obtain a safe compromise between the lesion dose and healthy adjacent structures. Study of dose-volume histograms, coverage indices and 3D imaging permit the optimization of irradiation. For lesions close to or included in a critical area, the prescribed dose is planned using the inverse planing method. Implementation of the successively described steps is mandatory to insure the prescription of an optimized dose. The whole procedure is based on the delineation of the lesion and adjacent healthy tissues. There are sometimes difficulties to assess the delineation and the volume of the target, however improvement of local control rates and reduction of secondary effects are the proof that the totality of the successive procedures are progressively improved. In practice, stereotactic intracranial radiotherapy is a continually improved treatment method, which constantly benefits from improvements in the choice of indications, imaging, techniques of irradiation, planing/optimization methodology and irradiation technique and from data collected from prolonged follow-up. (authors)

  9. Metastable states of plasma particles close to a charged surface

    Energy Technology Data Exchange (ETDEWEB)

    Shavlov, A. V., E-mail: shavlov@ikz.ru [The Institute of the Earth Cryosphere, RAS Siberian branch, 625000, P.O. 1230, Tyumen (Russian Federation); Tyumen State Oil and Gas University, 38, Volodarskogo St., 625000, Tyumen (Russian Federation); Dzhumandzhi, V. A. [The Institute of the Earth Cryosphere, RAS Siberian branch, 625000, P.O. 1230, Tyumen (Russian Federation)

    2015-09-15

    The free energy of the plasma particles and the charged surface that form an electroneutral system is calculated on the basis of the Poisson-Boltzmann equation. It is shown that, owing to correlation of light plasma particles near the charged surface and close to heavy particles of high charge, there can be metastable states in plasma. The corresponding phase charts of metastable states of the separate components of plasma, and plasma as a whole, are constructed. These charts depend on temperature, the charge magnitude, the size of the particles, and the share of the charge of the light carriers out of the total charge of the plasma particles.

  10. Intracranial radiosurgery in the Netherlands. A planning comparison of available systems with regard to physical aspects and workload.

    NARCIS (Netherlands)

    Schoonbeek, A.; Monshouwer, R.; Hanssens, P.; Raaijmakers, E.; Nowak, P.; Marijnissen, J.P.; Lagerwaard, F.J.; Cuijpers, J.P.; Vonk, E.J.; Maazen, R.W.M. van der

    2010-01-01

    Different planning and treatment systems for intracranial stereotactic radiosurgery available in the Netherlands are compared. The systems for intracranial radiosurgery include: Gamma Knife, Cyberknife, Novalis, and Tomotherapy. Electronic data of 5 patients was transferred to all participating

  11. Intensity-modulated stereotactic radiosurgery using dynamic micro-multileaf collimation

    International Nuclear Information System (INIS)

    Benedict, Stanley H.; Cardinale, Robert M.; Wu Qiuwen; Zwicker, Robert D.; Broaddus, William C.; Mohan, Radhe

    2001-01-01

    Purpose: The implementation of dynamic leaf motion on a micro-multileaf collimator system provides the capability for intensity-modulated stereotactic radiosurgery (IMSRS), and the consequent potential for improved dose distributions for irregularly shaped tumor volumes adjacent to critical organs. This study explores the use of IMSRS to provide improved tumor coverage and normal tissue sparing for small cranial tumors relative to plans based on multiple fixed uniform-intensity beams or traditional circular collimator arc-based stereotactic techniques. Methods and Materials: Four patient cases involving small brain lesions are presented and analyzed. The cases were chosen to include a representative selection of target shapes, number of targets, and adjacent critical areas. Patient plans generated for these comparisons include standard arcs with multiple circular collimators, and fixed noncoplanar static fields with uniform-intensity beams and IMSRS. Parameters used for evaluation of the plans include the percentage of irradiated volume to tumor volume (PITV), normal tissue dose-volume histograms, and dose-homogeneity ratios. All IMSRS plans were computed using previously established IMRT techniques adapted for use with the BrainLAB M3 micro-multileaf collimator. The algorithms comprising the IMRT system for optimization of intensity distributions and conversion into leaf trajectories of the BrainLab M3 were developed at our institution. The ADAC Pinnacle 3 radiation treatment-planning system was used for dose calculations and for input of contours for target volumes and normal critical structures. Results: For all cases, the IMSRS plans showed a high degree of conformity of the dose distribution with the target shape. The IMSRS plans provided either (1) a smaller volume of normal tissue irradiated to significant dose levels, generally taken as doses greater than 50% of the prescription, or (2) a lower dose to an important adjacent critical organ. The reduction in

  12. Stereotactic radiosurgery for brain metastasis: Pitie-Salpetriere Hospital experience

    International Nuclear Information System (INIS)

    Feuvret, L.; Germain, I.; Cornu, P.; Boisserie, G.; Dormont, D.; Hardiman, C.; Tep, B.; Faillot, T.; Duffau, H.; Simon, J.M.; Dendale, R.; Delattre, J.Y.; Poisson, M.; Marsault, C.; Philippon, J.; Fohanno, D.; Baillet, F.; Mazeron, J.J.

    1998-01-01

    Retrospective analysis of the influence of clinical and technical factors on local control and survival after radiosurgery for brain metastasis. From january 1994 to December 1996, 42 patients presenting with 71 metastases underwent radiosurgery for brain metastasis. The median age was 56 years and the median Karnofsky index 80. Primary sites included: lung (20 patients), kidney (seven), breast (five), colon (two), melanoma (three), osteosarcoma (one) and it was unknown for three patients. Seventeen patients had extracranial metastasis. Twenty-four patients were treated at recurrence which occurred after whole brain irradiation (12 patients), surgical excision (four) or after both treatments (eight). Thirty-six sessions of radiosurgery have been realized for one metastasis and 13 for two, three or four lesions. The median metastasis diameter was 21 mm and the median volume 1.7 cm 3 . The median peripheral dose to the lesion was 14 Gy, and the median dose at the isocenter 20 Gy. Sixty-five metastasis were evaluable for response analysis. The overall local control rate was 82% and the 1-year actuarial rate was 72%. In univariate analysis, theoretical radioresistance (P = 0.001), diameter less than 3 cm (P = 0.039) and initial treatment with radiosurgery (P 0.041) were significantly associated with increased local control. Only the first two factors remained significant in multivariate analysis. No prognostic factor of overall survival was identified. The median survival was 12 months. Six patients had a symptomatic oedema (RTOG grade 2), only one of which requiring a surgical excision. In conclusion, 14 Gy delivered at the periphery of metastasis seems to be a sufficient dose to control most brain metastases, with a minimal toxicity. Better results were obtained for lesions initially treated with radiosurgery, theoretically radioresistant and with a diameter less than 3 cm. (authors)

  13. Evaluation of Image-Guided Positioning for Frameless Intracranial Radiosurgery

    International Nuclear Information System (INIS)

    Lamba, Michael; Breneman, John C.; Warnick, Ronald E.

    2009-01-01

    Purpose: The standard for target alignment and immobilization in intracranial radiosurgery is frame-based alignment and rigid immobilization using a stereotactic head ring. Recent improvements in image-guidance systems have introduced the possibility of image-guided radiosurgery with nonrigid immobilization. We present data on the alignment accuracy and patient stability of a frameless image-guided system. Methods and Materials: Isocenter alignment errors were measured for in vitro studies in an anthropomorphic phantom for both frame-based stereotactic and frameless image-guided alignment. Subsequently, in vivo studies assessed differences between frame-based and image-guided alignment in patients who underwent frame-based intracranial radiosurgery. Finally, intratreatment target stability was determined by image-guided alignment performed before and after image-guided mask immobilized radiosurgery. Results: In vitro hidden target localization errors were comparable for the framed (0.7 ± 0.5 mm) and image-guided (0.6 ± 0.2 mm) techniques. The in vivo differences in alignment were 0.9 ± 0.5 mm (anteroposterior), -0.2 ± 0.4 mm (superoinferior), and 0.3 ± 0.5 mm (lateral). For in vivo stability tests, the mean distance differed between the pre- and post-treatment positions with mask-immobilized radiosurgery by 0.5 ± 0.3 mm. Conclusion: Frame-based and image-guided alignment accuracy in vitro was comparable for the system tested. In vivo tests showed a consistent trend in the difference of alignment in the anteroposterior direction, possibly due to torque to the ring and mounting system with frame-based localization. The mask system as used appeared adequate for patient immobilization.

  14. Radiosurgery for acoustic neurinomas: Early experience

    International Nuclear Information System (INIS)

    Linskey, M.E.; Lunsford, L.D.; Flickinger, J.C.

    1990-01-01

    We reviewed our early experience with the first 26 patients with acoustic neurinomas (21 unilateral, 5 bilateral) treated by stereotactic radiosurgery using the first North American 201-source cobalt-60 gamma knife. Follow-up ranged from 6 to 19 months (median, 13 months). Serial postoperative imaging showed either a decrease in tumor size (11 patients) or growth arrest (15 patients). Loss of central contrast enhancement was a characteristic change (18 patients). Seven patients had good or serviceable hearing preoperatively. In all 7 the preoperative hearing status was retained immediately after radiosurgery. At follow-up, 3 had preserved hearing, 1 had reduced hearing, and 3 had lost all hearing in the treated ear. Hearing in 1 patient that was nonserviceable preoperatively later improved to a serviceable hearing level. Delayed facial paresis developed in 6 patients, and delayed trigeminal sensory loss developed in 7 patients, none of whom had significant deficits before radiosurgery. Both facial and trigeminal deficits tended to improve within 3 to 6 months of onset with excellent recovery anticipated. Lower cranial nerve dysfunction was not observed. All 26 patients remain at their preoperative employment or functional status. At present, stereotactic radiosurgery is an alternative treatment for acoustic neurinomas in patients who are elderly, have significant concomitant medical problems, have a tumor in their only hearing ear, have bilateral acoustic neurinomas, refuse microsurgical excision, or have recurrent tumor despite surgical resection. Although longer and more extensive follow-up is required, the control of tumor growth and the acceptable rate of complications in this early experience testifies to the future expanding role of this technique in the management of selected acoustic neurinomas

  15. Multileaf collimator-based linear accelerator radiosurgery: five-year efficiency analysis.

    Science.gov (United States)

    Lawson, Joshua D; Fox, Tim; Waller, Anthony F; Davis, Lawrence; Crocker, Ian

    2009-03-01

    In 1989, Emory University initiated a linear accelerator (linac) radiosurgery program using circular collimators. In 2001, the program converted to a multileaf collimator. Since then, the treatment parameters of each patient have been stored in the record-and-verify system. Three major changes have occurred in the radiosurgery program in the past 6 years: in 2002, treatment was changed from static conformal beams to dynamic conformal arc (DCA) therapy, and all patients were imaged before treatment. Beginning in 2005, a linac was used, with the opportunity to treat at higher dose rates (600-1,000 monitor units/min). The aim of this study was to analyze the time required to deliver radiosurgery and the factors affecting treatment delivery. Benchmark data are provided for centers contemplating initiating linac radiosurgery programs. Custom software was developed to mine the record-and-verify system database and automatically perform a chart review on patients who underwent stereotactic radiosurgery from March 2001 to October 2006. The software extracted 510 patients who underwent stereotactic radiosurgery, and the following information was recorded for each patient: treatment technique, treatment time (from initiation of imaging, if done, to completion of therapy), number of isocenters, number of fields, total monitor units, and dose rate. Of the 510 patients, 395 were treated with DCA therapy and 115 with static conformal beams. The average number of isocenters treated was 1.06 (range, 1-4). The average times to deliver treatment were 24.1 minutes for patients who underwent DCA therapy and 19.3 minutes for those treated with static conformal beams, reflecting the lack of imaging in the latter patients. Eighty percent of patients were treated in question the need for a dedicated radiosurgery unit for even busy treatment centers.

  16. Stereotactic Bragg peak proton radiosurgery method

    International Nuclear Information System (INIS)

    Kjellberg, R.N.

    1979-01-01

    A brief description of the technical aspects of a stereotactic Bragg peak proton radiosurgical method for the head is presented. The preparatory radiographic studies are outlined and the stereotactic instrument and positioning of the patient are described. The instrument is so calibrated that after corrections for soft tissue and bone thickness, the Bragg peak superimposes upon the intracranial target. The head is rotated at specific intervals to allow predetermined portals of access for the beam path, all of which converge on the intracranial target. Normally, portals are arranged to oppose and overlap from both sides of the head. Using a number of beams (in sequence) on both sides of the head, the target dose is far greater than the path dose. The procedure normally takes 3/2-2 hours, following which the patient can walk away. (Auth./C.F.)

  17. Charged particle multiplicities in heavy and light quark initiated events above the $Z^0$ peak

    CERN Document Server

    Abbiendi, G.; Akesson, P.F.; Alexander, G.; Allison, John; Amaral, P.; Anagnostou, G.; Anderson, K.J.; Arcelli, S.; Asai, S.; Axen, D.; Azuelos, G.; Bailey, I.; Barberio, E.; Barlow, R.J.; Batley, R.J.; Bechtle, P.; Behnke, T.; Bell, Kenneth Watson; Bell, P.J.; Bella, G.; Bellerive, A.; Benelli, G.; Bethke, S.; Biebel, O.; Bloodworth, I.J.; Boeriu, O.; Bock, P.; Bonacorsi, D.; Boutemeur, M.; Braibant, S.; Brigliadori, L.; Brown, Robert M.; Buesser, K.; Burckhart, H.J.; Campana, S.; Carnegie, R.K.; Caron, B.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Csilling, A.; Cuffiani, M.; Dado, S.; Dallison, S.; De Roeck, A.; De Wolf, E.A.; Desch, K.; Dienes, B.; Donkers, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Elfgren, E.; Etzion, E.; Fabbri, F.; Feld, L.; Ferrari, P.; Fiedler, F.; Fleck, I.; Ford, M.; Frey, A.; Furtjes, A.; Gagnon, P.; Gary, John William; Gaycken, G.; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Giunta, Marina; Goldberg, J.; Gross, E.; Grunhaus, J.; Gruwe, M.; Gunther, P.O.; Gupta, A.; Hajdu, C.; Hamann, M.; Hanson, G.G.; Harder, K.; Harel, A.; Harin-Dirac, M.; Hauschild, M.; Hauschildt, J.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Hensel, C.; Herten, G.; Heuer, R.D.; Hill, J.C.; Hoffman, Kara Dion; Homer, R.J.; Horvath, D.; Howard, R.; Igo-Kemenes, P.; Ishii, K.; Jeremie, H.; Jovanovic, P.; Junk, T.R.; Kanaya, N.; Kanzaki, J.; Karapetian, G.; Karlen, D.; Kartvelishvili, V.; Kawagoe, K.; Kawamoto, T.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kim, D.H.; Klein, K.; Klier, A.; Kluth, S.; Kobayashi, T.; Kobel, M.; Komamiya, S.; Kormos, Laura L.; Kramer, T.; Kress, T.; Krieger, P.; von Krogh, J.; Krop, D.; Kruger, K.; Kuhl, T.; Kupper, M.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Layter, J.G.; Leins, A.; Lellouch, D.; Lettso, J.; Levinson, L.; Lillich, J.; Lloyd, S.L.; Loebinger, F.K.; Lu, J.; Ludwig, J.; Macpherson, A.; Mader, W.; Marcellini, S.; Marchant, T.E.; Martin, A.J.; Martin, J.P.; Masetti, G.; Mashimo, T.; Mattig, Peter; McDonald, W.J.; McKenna, J.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Mendez-Lorenzo, P.; Menges, W.; Merritt, F.S.; Mes, H.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Moed, S.; Mohr, W.; Mori, T.; Mutter, A.; Nagai, K.; Nakamura, I.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oh, A.; Okpara, A.; Oreglia, M.J.; Orito, S.; Pahl, C.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poli, B.; Polok, J.; Pooth, O.; Przybycien, M.; Quadt, A.; Rabbertz, K.; Rembser, C.; Renkel, P.; Rick, H.; Roney, J.M.; Rosati, S.; Rozen, Y.; Runge, K.; Sachs, K.; Saeki, T.; Sahr, O.; Sarkisyan, E.K.G.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schoerner-Sadenius, Thomas; Schroder, Matthias; Schumacher, M.; Schwick, C.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Sherwood, P.; Siroli, G.; Skuja, A.; Smith, A.M.; Sobie, R.; Soldner-Rembold, S.; Spano, F.; Stahl, A.; Stephens, K.; Strom, David M.; Strohmer, R.; Tarem, S.; Tasevsky, M.; Taylor, R.J.; Teuscher, R.; Thomson, M.A.; Torrence, E.; Toya, D.; Tran, P.; Trefzger, T.; Tricoli, A.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Ujvari, B.; Vachon, B.; Vollmer, C.F.; Vannerem, P.; Verzocchi, M.; Voss, H.; Vossebeld, J.; Waller, D.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wengler, T.; Wermes, N.; Wetterling, D.; Wilson, G.W.; Wilson, J.A.; Wolf, G.; Wyatt, T.R.; Yamashita, S.; Zer-Zion, D.; Zivkovic, Lidija

    2002-01-01

    We have measured the mean charged particle multiplicities separately for bbbar, ccbar and light quark (uubar, ddbar, ssbar) initiated events produced in e+e- annihilations at LEP. The data were recorded with the OPAL detector at eleven different energies above Z0 peak, corresponding to the full statistics collected at LPE1.5 and LEP2. The difference in mean charged and particle multiplicities for bbbar and light quark events, delta_bl, measured over this energy range is consistent with an energy independent behaviour, as predicted by QCD, but is inconsistent with the prediction of a more phenomenological approach which assumes that the multiplicity accompanying the decay of a heavy quark is independent of the quark mass itself. Our results, which can be combined into the single measurement delta_bl = 3.44+-0.40(stat)+-0.89(syst) at a luminosity weighted average centre-of mass energy of 195 GeV, are also consistent with an energy independent behaviour as extrapolated from lower energy data.

  18. Outcomes of Diffusion Tensor Tractography-Integrated Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Tomoyuki, E-mail: kouga-tky@umin.ac.jp [Department of Neurosurgery, University of Tokyo Hospital, Tokyo (Japan); Maruyama, Keisuke; Kamada, Kyousuke; Ota, Takahiro; Shin, Masahiro [Department of Neurosurgery, University of Tokyo Hospital, Tokyo (Japan); Itoh, Daisuke [Department of Radiology, University of Tokyo Hospital, Tokyo (Japan); Kunii, Naoto [Department of Neurosurgery, University of Tokyo Hospital, Tokyo (Japan); Ino, Kenji; Terahara, Atsuro; Aoki, Shigeki; Masutani, Yoshitaka [Department of Radiology, University of Tokyo Hospital, Tokyo (Japan); Saito, Nobuhito [Department of Neurosurgery, University of Tokyo Hospital, Tokyo (Japan)

    2012-02-01

    Purpose: To analyze the effect of use of tractography of the critical brain white matter fibers created from diffusion tensor magnetic resonance imaging on reduction of morbidity associated with radiosurgery. Methods and Materials: Tractography of the pyramidal tract has been integrated since February 2004 if lesions are adjacent to it, the optic radiation since May 2006, and the arcuate fasciculus since October 2007. By visually confirming the precise location of these fibers, the dose to these fiber tracts was optimized. One hundred forty-four consecutive patients with cerebral arteriovenous malformations who underwent radiosurgery with this technique between February 2004 and December 2009 were analyzed. Results: Tractography was prospectively integrated in 71 of 155 treatments for 144 patients. The pyramidal tract was visualized in 45, the optic radiation in 22, and the arcuate fasciculus in 13 (two tracts in 9). During the follow-up period of 3 to 72 months (median, 23 months) after the procedure, 1 patient showed permanent worsening of pre-existing dysesthesia, and another patient exhibited mild transient hemiparesis 12 months later but fully recovered after oral administration of corticosteroid agents. Two patients had transient speech disturbance before starting integration of the arcuate fasciculus tractography, but no patient thereafter. Conclusion: Integrating tractography helped prevent morbidity of radiosurgery in patients with brain arteriovenous malformations.

  19. Light-particle emission and heavy residues from nucleus-nucleus collisions

    International Nuclear Information System (INIS)

    Caplar, R.; Hoelbling, S.; Gentner, R.; Lassen, L.; Oberstedt, A.

    1991-01-01

    We have investigated the interrelation between light-particle multiplicities and mass resp. charge distributions of heavy residues from complete and incomplete fusion of heavy ions. We have shown that a simple statistical model provides the possibility of quantitatively correlating heavy-residue distributions and corresponding light-particle multiplicities both at the Coulomb barrier and at higher energies where preequilibrium emission occurs. (author). 8 refs, 4 figs, 1 tab

  20. Charged particle yields and spectra in p+p and Heavy Ion Collisions with ATLAS at the LHC

    CERN Document Server

    Dolejší, J; The ATLAS collaboration

    2010-01-01

    The ATLAS experiment has extensive charged particle tracking over full azimuth and within |eta|<2.5. The spectrometer consists of three pixel layers and four double-layer strip layers, giving 11 space points in all. The existing tracking software used for proton-proton collisions has been optimized for the high-multiplicity heavy ion environment. Extensions of the existing tracking to lower pT (100 MeV) using tracks and pixel tracklets, work underway for p+p, will be discussed in the context of heavy ion collisions. Finally, by correlating high momentum tracks with the ATLAS calorimetry, fake tracks can also be rejected at very high pT. The physics performance of the ATLAS inner detector for dN/deta, inclusive particle spectra, and two-particle correlations (in delta-eta and delta-phi) will be discussed. The tracking performance within jets, which is essential for the measurement of jet fragmentation functions, will also be presented.

  1. SU-E-T-642: Safety Procedures for Error Elimination in Cyberknife Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT)

    International Nuclear Information System (INIS)

    Hussain, A; Alkafi, A; Al-Najjar, W; Moftah, B

    2014-01-01

    Purpose: Cyberknife system is used for providing stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) hypofractionation scheme. The whole treatment delivery is based on live imaging of the patient. The minor error made at any stage may bring severe radiation injury to the patient or damage to the system itself. Several safety measures were taken to make the system safer. Methods: The radiation treatment provided thru a 6MV linac attached to Kuka robot (Cyberknife G4, Accuray Inc. Sunnyvale, CA, USA). Several possible errors were identified related to patient alignment, treatment planning, dose delivery and physics quality assurance. During dose delivery, manual and visual checks were introduced to confirm pre and intra-treatment imaging to reduce possible errors. One additional step was introduced to confirm that software tracking-tools had worked correctly with highest possible confidence level. Robotic head move in different orientations over and around the patient body, the rigidity of linac-head cover and other accessories was checked periodically. The vender was alerted when a tiny or bigger piece of equipment needed additional interlocked support. Results: As of our experience treating 525 patients on Cyberknife during the last four years, we saw on and off technical issues. During image acquisition, it was made essential to follow the site-specific imaging protocols. Adequate anatomy was contoured to document the respective doses. Followed by auto-segmentation, manual tweaking was performed on every structure. The calculation box was enclosing the whole image during the final calculation. Every plan was evaluated on slice-by slice basis. To review the whole process, a check list was maintained during the physics 2nd-check. Conclusion: The implementation of manual and visual additional checks introduced along with automated checks for confirmation was found promising in terms of reduction in systematic errors and making the system

  2. X-ray stereotactic radiosurgery for cerebral arteriovenous malformation in the teenagers

    International Nuclear Information System (INIS)

    Wang Qing; Huang Minggang; Hou Xiaoling

    2002-01-01

    Objective: To analyze the long-term results of cerebral arteriovenous malformation (AVM) in the teenagers treated by X-ray stereotactic radiosurgery (SRS). Methods: From May 1996 to May 1998, 66 patients with AVM were treated by X-ray SRS with 65 patients followed up for 3-5 years. There were 42 men and 24 women who ranged in age from 8 to 39 years. The AVM volume ranged from 0.32 cm 3 to 42.88 cm 3 . The peripheral dose was prescribed to the 80% isodose line, which ranged from 18 Gy to 23 Gy, with a median of 19.3 Gy. Results: The complete obliteration rate was 65.2%, with 30.3% at 1 year and 62.1% at 2 years. Logistic regression analysis showed that the lesion volume was the only factor for obliteration, the complete obliteration rates were 87.1% and 45.7% for 3 and >10 cm 3 (x 2 = 10.644, P 3 and > 10 cm 3 (t = 2.066, P 20 Gy and 2 = 0.003, P > 0.05) and 1.474 years, 1.667 years (t = 1.073, P > 0.05) for children and young people, showing irrelevancy to age. Conclusions: The X-ray SRS is effective and safe for cerebral AVM, it gives high obliteration rate for AVM of volume 3 and serves as an auxiliary to surgery and endovascular embolization

  3. Search for Stable Heavy Charged Particles in $e^+ e^-$ Collisions at $\\sqrt{s}$ = 130-136, 161 and 172 GeV

    CERN Document Server

    Abreu, P; Adye, T; Ajinenko, I; Alekseev, G D; Alemany, R; Allport, P P; Almehed, S; Amaldi, Ugo; Amato, S; Andreazza, A; Andrieux, M L; Antilogus, P; Apel, W D; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Bambade, P; Barão, F; Barbi, M S; Barbiellini, Guido; Bardin, Dimitri Yuri; Barker, G; Baroncelli, A; Bärring, O; Barrio, J A; Bartl, Walter; Bates, M J; Battaglia, Marco; Baubillier, M; Baudot, J; Becks, K H; Begalli, M; Beillière, P; Belokopytov, Yu A; Belous, K S; Benvenuti, Alberto C; Berggren, M; Bertini, D; Bertrand, D; Besançon, M; Bianchi, F; Bigi, M; Bilenky, S M; Billoir, P; Bizouard, M A; Bloch, D; Blume, M; Bolognese, T; Bonesini, M; Bonivento, W; Booth, P S L; Borisov, G; Bosio, C; Botner, O; Boudinov, E; Bouquet, B; Bourdarios, C; Bowcock, T J V; Bozzo, M; Branchini, P; Brand, K D; Brenke, T; Brenner, R A; Bricman, C; Brown, R C A; Brückman, P; Brunet, J M; Bugge, L; Buran, T; Burgsmüller, T; Buschmann, P; Cabrera, S; Caccia, M; Calvi, M; Camacho-Rozas, A J; Camporesi, T; Canale, V; Canepa, M; Cankocak, K; Cao, F; Carena, F; Carroll, L; Caso, Carlo; Castillo-Gimenez, M V; Cattai, A; Cavallo, F R; Chabaud, V; Charpentier, P; Chaussard, L; Checchia, P; Chelkov, G A; Chen, M; Chierici, R; Chliapnikov, P V; Chochula, P; Chorowicz, V; Cindro, V; Collins, P; Contri, R; Cortina, E; Cosme, G; Cossutti, F; Cowell, J H; Crawley, H B; Crennell, D J; Crosetti, G; Cuevas-Maestro, J; Czellar, S; Dahl-Jensen, Erik; Dahm, J; D'Almagne, B; Dam, M; Damgaard, G; Dauncey, P D; Davenport, Martyn; Da Silva, W; Defoix, C; Deghorain, A; Della Ricca, G; Delpierre, P A; Demaria, N; De Angelis, A; de Boer, Wim; De Brabandere, S; De Clercq, C; La Vaissière, C de; De Lotto, B; De Min, A; De Paula, L S; De Saint-Jean, C; Dijkstra, H; Di Ciaccio, Lucia; Di Diodato, A; Djama, F; Djannati, A; Dolbeau, J; Doroba, K; Dracos, M; Drees, J; Drees, K A; Dris, M; Durand, J D; Edsall, D M; Ehret, R; Eigen, G; Ekelöf, T J C; Ekspong, Gösta; Elsing, M; Engel, J P; Erzen, B; Espirito-Santo, M C; Falk, E; Fassouliotis, D; Feindt, Michael; Fenyuk, A; Ferrer, A; Fichet, S; Filippas-Tassos, A; Firestone, A; Fischer, P A; Föth, H; Fokitis, E; Fontanelli, F; Formenti, F; Franek, B J; Frenkiel, P; Fries, D E C; Frodesen, A G; Frühwirth, R; Fulda-Quenzer, F; Fuster, J A; Galloni, A; Gamba, D; Gandelman, M; García, C; García, J; Gaspar, C; Gasparini, U; Gavillet, P; Gazis, E N; Gelé, D; Gerber, J P; Gerdyukov, L N; Gokieli, R; Golob, B; Gopal, Gian P; Gorn, L; Górski, M; Guz, Yu; Gracco, Valerio; Graziani, E; Green, C; Grefrath, A; Gris, P; Grosdidier, G; Grzelak, K; Gumenyuk, S A; Gunnarsson, P; Günther, M; Guy, J; Hahn, F; Hahn, S; Hajduk, Z; Hallgren, A; Hamacher, K; Harris, F J; Hedberg, V; Henriques, R P; Hernández, J J; Herquet, P; Herr, H; Hessing, T L; Heuser, J M; Higón, E; Hilke, Hans Jürgen; Hill, T S; Holmgren, S O; Holt, P J; Holthuizen, D J; Hoorelbeke, S; Houlden, M A; Hrubec, Josef; Huet, K; Hultqvist, K; Jackson, J N; Jacobsson, R; Jalocha, P; Janik, R; Jarlskog, C; Jarlskog, G; Jarry, P; Jean-Marie, B; Johansson, E K; Jönsson, L B; Jönsson, P E; Joram, Christian; Juillot, P; Kaiser, M; Kapusta, F; Karafasoulis, K; Karlsson, M; Karvelas, E; Katsanevas, S; Katsoufis, E C; Keränen, R; Khokhlov, Yu A; Khomenko, B A; Khovanskii, N N; King, B J; Kjaer, N J; Klapp, O; Klein, H; Klovning, A; Kluit, P M; Kokkinias, P; Konoplyannikov, A K; Koratzinos, M; Korcyl, K; Kostyukhin, V; Kourkoumelis, C; Kuznetsov, O; Krammer, Manfred; Kreuter, C; Kronkvist, I J; Krumshtein, Z; Krupinski, W; Kubinec, P; Kucewicz, W; Kurvinen, K L; Lacasta, C; Laktineh, I; Lamsa, J; Lanceri, L; Lane, D W; Langefeld, P; Laugier, J P; Lauhakangas, R; Leder, Gerhard; Ledroit, F; Lefébure, V; Legan, C K; Leitner, R; Lemonne, J; Lenzen, Georg; Lepeltier, V; Lesiak, T; Libby, J; Liko, D; Lindner, R; Lipniacka, A; Lippi, I; Lörstad, B; Loken, J G; López, J M; Loukas, D; Lutz, P; Lyons, L; MacNaughton, J N; Maehlum, G; Mahon, J R; Malmgren, T G M; Malychev, V; Mandl, F; Marco, J; Marco, R P; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Martínez-Rivero, C; Martínez-Vidal, F; Martí i García, S; Matorras, F; Matteuzzi, C; Matthiae, Giorgio; Mazzucato, M; McCubbin, M L; McKay, R; McNulty, R; Medbo, J; Merk, M; Meroni, C; Meyer, S; Meyer, W T; Michelotto, M; Migliore, E; Mirabito, L; Mitaroff, Winfried A; Mjörnmark, U; Moa, T; Møller, R; Mönig, K; Monge, M R; Morettini, P; Müller, H; Münich, K; Mulders, M; Mundim, L M; Murray, W J; Muryn, B; Myatt, Gerald; Naraghi, F; Navarria, Francesco Luigi; Navas, S; Nawrocki, K; Negri, P; Némécek, S; Neumann, W; Neumeister, N; Nicolaidou, R; Nielsen, B S; Nieuwenhuizen, M; Nikolaenko, V; Niss, P; Nomerotski, A; Normand, Ainsley; Novák, M; Oberschulte-Beckmann, W; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, Risto; Österberg, K; Ouraou, A; Paganini, P; Paganoni, M; Pagès, P; Pain, R; Palka, H; Papadopoulou, T D; Papageorgiou, K; Pape, L; Parkes, C; Parodi, F; Passeri, A; Pegoraro, M; Peralta, L; Pernicka, Manfred; Perrotta, A; Petridou, C; Petrolini, A; Phillips, H T; Piana, G; Pierre, F; Pimenta, M; Podobnik, T; Podobrin, O; Pol, M E; Polok, G; Poropat, P; Pozdnyakov, V; Privitera, P; Pukhaeva, N; Pullia, Antonio; Radojicic, D; Ragazzi, S; Rahmani, H; Rames, J; Ratoff, P N; Read, A L; Reale, M; Rebecchi, P; Redaelli, N G; Regler, Meinhard; Reid, D; Reinhardt, R; Renton, P B; Resvanis, L K; Richard, F; Richardson, J; Rídky, J; Rinaudo, G; Ripp, I; Romero, A; Roncagliolo, I; Ronchese, P; Roos, L; Rosenberg, E I; Roudeau, Patrick; Rovelli, T; Ruhlmann-Kleider, V; Ruiz, A; Rybicki, K; Saarikko, H; Sacquin, Yu; Sadovskii, A; Sahr, O; Sajot, G; Salt, J; Sánchez, J; Sannino, M; Schimmelpfennig, M; Schneider, H; Schwickerath, U; Schyns, M A E; Sciolla, G; Scuri, F; Seager, P; Sedykh, Yu; Segar, A M; Seitz, A; Sekulin, R L; Serbelloni, L; Shellard, R C; Siegrist, P; Silvestre, R; Simonetti, S; Simonetto, F; Sissakian, A N; Sitár, B; Skaali, T B; Smadja, G; Smirnov, N; Smirnova, O G; Smith, G R; Solovyanov, O; Sosnowski, R; Souza-Santos, D; Spassoff, Tz; Spiriti, E; Sponholz, P; Squarcia, S; Stampfer, D; Stanescu, C; Stanic, S; Stapnes, Steinar; Stavitski, I; Stevenson, K; Stocchi, A; Strauss, J; Strub, R; Stugu, B; Szczekowski, M; Szeptycka, M; Tabarelli de Fatis, T; Tavernet, J P; Chernyaev, E; Thomas, J; Tilquin, A; Timmermans, J; Tkatchev, L G; Todorov, T; Todorova, S; Toet, D Z; Tomaradze, A G; Tomé, B; Tonazzo, A; Tortora, L; Tranströmer, G; Treille, D; Tristram, G; Trombini, A; Troncon, C; Tsirou, A L; Turluer, M L; Tyapkin, I A; Tyndel, M; Tzamarias, S; Überschär, B; Ullaland, O; Uvarov, V; Valenti, G; Vallazza, E; Van der Velde, C; van Apeldoorn, G W; van Dam, P; Van Doninck, W K; Van Eldik, J; Van Lysebetten, A; Vassilopoulos, N; Vegni, G; Ventura, L; Venus, W A; Verbeure, F; Verlato, M; Vertogradov, L S; Vilanova, D; Vincent, P; Vitale, L; Vodopyanov, A S; Vrba, V; Wahlen, H; Walck, C; Weierstall, M; Weilhammer, Peter; Weiser, C; Wetherell, Alan M; Wicke, D; Wickens, J H; Wielers, M; Wilkinson, G R; Williams, W S C; Winter, M; Witek, M; Wlodek, T; Woschnagg, K; Yip, K; Yushchenko, O P; Zach, F; Zaitsev, A; Zalewska-Bak, A; Zalewski, Piotr; Zavrtanik, D; Zevgolatakos, E; Zimin, N I; Zito, M; Zontar, D; Zucchelli, G C; Zumerle, G

    1997-01-01

    A search for stable or long-lived heavy charged particles in $e^+e^-$ interactions at energies of 130-136, 161 and 172 GeV has been performed using the data taken by the DELPHI experiment at LEP. The search is based on particle identification provided by the Time Projection Chamber and the Ring Imaging Cherenkov detector. Upper limits at 95\\% confidence level are derived on the cross-section for heavy long-lived pair-produced charge $\\pm e$ and $\\pm 2/3e$ particles in the range of 0.4-2.3 pb for masses from 45 to 84 GeV/$c^2$. Within supersymmetric extensions of the Standard Model, long-lived charginos with masses from 45 to 84 (80)~GeV/$c^2$ for high (low) sneutrino masses can be excluded at 95\\% confidence level. %Mass limits for long-lived sleptons are obtained. %For selectrons no general mass limits can be given. Left-handed (right-handed) long-lived or stable smuons and staus with masses between 45 and 68 (65)~GeV/$c^2$ can be excluded at 95\\% confidence level.

  4. Proton Stereotactic Radiosurgery for the Treatment of Benign Meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Halasz, Lia M., E-mail: lhalasz@partners.org [Harvard Radiation Oncology Program, Boston, Massachusetts (United States); Harvard Medical School, Boston, Massachusetts (United States); Bussiere, Marc R.; Dennis, Elizabeth R.; Niemierko, Andrzej [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Chapman, Paul H. [Department of Neurosurgery, Massachusetts General Hospital, Boston, Massachusetts (United States); Harvard Medical School, Boston, Massachusetts (United States); Loeffler, Jay S.; Shih, Helen A. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Harvard Medical School, Boston, Massachusetts (United States)

    2011-12-01

    Purpose: Given the excellent prognosis for patients with benign meningiomas, treatment strategies to minimize late effects are important. One strategy is proton radiation therapy (RT), which allows less integral dose to normal tissue and greater homogeneity than photon RT. Here, we report the first series of proton stereotactic radiosurgery (SRS) used for the treatment of meningiomas. Methods and Materials: We identified 50 patients with 51 histologically proven or image- defined, presumed-benign meningiomas treated at our institution between 1996 and 2007. Tumors of <4 cm in diameter and located {>=}2 mm from the optic apparatus were eligible for treatment. Indications included primary treatment (n = 32), residual tumor following surgery (n = 8), and recurrent tumor following surgery (n = 10). The median dose delivered was 13 Gray radiobiologic equivalent (Gy[RBE]) (range, 10.0-15.5 Gy[RBE]) prescribed to the 90% isodose line. Results: Median follow-up was 32 months (range, 6-133 months). Magnetic resonance imaging at the most recent follow-up or time of progression revealed 33 meningiomas with stable sizes, 13 meningiomas with decreased size, and 5 meningiomas with increased size. The 3-year actuarial tumor control rate was 94% (95% confidence interval, 77%-98%). Symptoms were improved in 47% (16/ 34) of patients, unchanged in 44% (15/34) of patients, and worse in 9% (3/34) of patients. The rate of potential permanent adverse effects after SRS was 5.9% (3/51 patients). Conclusions: Proton SRS is an effective therapy for small benign meningiomas, with a potentially lower rate of long-term treatment-related morbidity. Longer follow-up is needed to assess durability of tumor control and late effects.

  5. Stereotactic Radiosurgery with Neoadjuvant Embolization of Larger Arteriovenous Malformations: An Institutional Experience

    Directory of Open Access Journals (Sweden)

    Richard Dalyai

    2014-01-01

    Full Text Available Objective. This study investigates the safety and efficacy of a multimodality approach combining staged endovascular embolizations with subsequent SRS for the management of larger AVMs. Methods. Ninety-five patients with larger AVMs were treated with staged endovascular embolization followed by SRS between 1996 and 2011. Results. The median volume of AVM in this series was 28 cm3 and 47 patients (48% were Spetzler-Martin grade IV or V. Twenty-seven patients initially presented with hemorrhage. Sixty-one patients underwent multiple embolizations while a single SRS session was performed in 64 patients. The median follow-up after SRS session was 32 months (range 9–136 months. Overall procedural complications occurred in 14 patients. There were 13 minor neurologic complications and 1 major complication (due to embolization while four patients had posttreatment hemorrhage. Thirty-eight patients (40% were cured radiographically. The postradiosurgery actuarial rate of obliteration was 45% at 5 years, 56% at 7 years, and 63% at 10 years. In multivariate analysis, larger AVM size, deep venous drainage, and the increasing number of embolization/SRS sessions were negative predictors of obliteration. The number of embolizations correlated positively with the number of stereotactic radiosurgeries (P<0.005. Conclusions. Multimodality endovascular and radiosurgical approach is an efficacious treatment strategy for large AVM.

  6. Stereotactic radiosurgery for the treatment of arteriovenous malformations - preliminary results; Radiocirurgia estereotaxica no tratamento das malformacoes arteriovenosas - resultados preliminares

    Energy Technology Data Exchange (ETDEWEB)

    Penna, Antonio Belmiro Rodrigues Campbell [Hospital dos Servidores do Estado (HSE), Rio de Janeiro, RJ (Brazil). Servico de Radioterapia; Marchiori, Edson [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Dept. de Radiologia; Vieira, Sergio Lannes [Hospital Sao Vicente de Paulo, Rio de Janeiro, RJ (Brazil). Servico de Radioterapia; Rossini Junior, Olamir [Clinica Radioterapia Botafogo Ltda., Rio de Janeiro, RJ (Brazil)

    2000-08-01

    This paper presents the clinical and radiological results of six patients treated with stereotactic radiosurgery with a 6 MeV linear accelerator for arteriovenous malformations. All patients had been previously examined by neurosurgeons and neuroradiologists who contraindicated surgery or embolization due to the size and location of the nidus. Radiological investigations performed 12 to 36 months after the treatments showed complete response in five patients and partial response in one patient, adding up to a total response rate of 100%. No signs or symptoms of permanent injury to the cranial nerves or cerebral parenchyma were detected up to the last follow-up visit. No episodes of cerebral hemorrhage were diagnosed and no deaths related to the radiosurgical treatment were reported during the follow-up period. (author)

  7. Brain tumor radiosurgery. Current status and strategies to enhance the effect of radiosurgery

    International Nuclear Information System (INIS)

    Niranjan, A.; Lunsford, L.D.; Gobbel, G.T.; Kondziolka, D.; Maitz, A.; Flickinger, J.C.

    2000-01-01

    First, the current status of brain tumor radiosurgery is reviewed, and radiosurgery for brain tumors, including benign tumors, malignant tumors, primary glial tumors, and metastatic tumors, is described. Rapid developments in neuroimaging, stereotactic techniques, and robotic technology in the last decade have contributed to improved results and wider applications of radiosurgery. Radiosurgery has become the preferred management modality for many intracranial tumors, including schwannomas, meningiomas, and metastatic tumors. Although radiosurgery provides survival benefits in patients with diffuse malignant brain tumors, cure is still not possible. Microscopic tumor infiltration into surrounding normal tissue is the main cause of recurrence. Additional strategies are needed to specifically target tumor cells. Next, strategies to enhance the effect of radiosurgery are reviewed. Whereas the long-term clinical results of radiosurgery have established its role in the treatment of benign tumors, additional strategies are needed to improve cell killing in malignant brain tumors and to protect normal surrounding brain. The first strategy included the use of various agents to protect normal brain while delivering a high dose to the tumor cells, but finding an effective radioprotective agent has been problematic. Pentobarbital and 21-aminosteroid (21-AS) are presented as examples. The second strategy for radiation protection aimed at the repair of radiation-induced damage to the normal brain. The cause of radiation-induced breakdown of normal tissue is unclear. The white matter and the cerebral vasculature appear to be particularly susceptible to radiation. Oligodendrocytes and endothelial cells may be critical targets of radiation. The authors hypothesize that radiation-induced damage to these cell types can be repaired by neural stem cells. They also describe the use of tumor necrosis factor alpha (TNF-alpha) and neural stem cells as a means of enhancing the effect of

  8. Search for heavy long-lived multi-charged particles in $pp$ collisions at $\\sqrt{s}$=8 TeV using the ATLAS detector

    CERN Document Server

    Aad, Georges; Abdallah, Jalal; Abdinov, Ovsat; Aben, Rosemarie; Abolins, Maris; AbouZeid, Ossama; Abramowicz, Halina; Abreu, Henso; Abreu, Ricardo; Abulaiti, Yiming; Acharya, Bobby Samir; Adamczyk, Leszek; Adams, David; Adelman, Jahred; Adomeit, Stefanie; Adye, Tim; Affolder, Tony; Agatonovic-Jovin, Tatjana; Aguilar-Saavedra, Juan Antonio; Ahlen, Steven; Ahmadov, Faig; Aielli, Giulio; Akerstedt, Henrik; Åkesson, Torsten Paul Ake; Akimoto, Ginga; Akimov, Andrei; Alberghi, Gian Luigi; Albert, Justin; Albrand, Solveig; Alconada Verzini, Maria Josefina; Aleksa, Martin; Aleksandrov, Igor; Alexa, Calin; Alexander, Gideon; Alexopoulos, Theodoros; Alhroob, Muhammad; Alimonti, Gianluca; Alio, Lion; Alison, John; Alkire, Steven Patrick; Allbrooke, Benedict; Allport, Phillip; Aloisio, Alberto; Alonso, Alejandro; Alonso, Francisco; Alpigiani, Cristiano; Altheimer, Andrew David; Alvarez Gonzalez, Barbara; Άlvarez Piqueras, Damián; Alviggi, Mariagrazia; Amako, Katsuya; Amaral Coutinho, Yara; Amelung, Christoph; Amidei, Dante; Amor Dos Santos, Susana Patricia; Amorim, Antonio; Amoroso, Simone; Amram, Nir; Amundsen, Glenn; Anastopoulos, Christos; Ancu, Lucian Stefan; Andari, Nansi; Andeen, Timothy; Anders, Christoph Falk; Anders, Gabriel; Anders, John Kenneth; Anderson, Kelby; Andreazza, Attilio; Andrei, George Victor; Angelidakis, Stylianos; Angelozzi, Ivan; Anger, Philipp; Angerami, Aaron; Anghinolfi, Francis; Anisenkov, Alexey; Anjos, Nuno; Annovi, Alberto; Antonelli, Mario; Antonov, Alexey; Antos, Jaroslav; Anulli, Fabio; Aoki, Masato; Aperio Bella, Ludovica; Arabidze, Giorgi; Arai, Yasuo; Araque, Juan Pedro; Arce, Ayana; Arduh, Francisco Anuar; Arguin, Jean-Francois; Argyropoulos, Spyridon; Arik, Metin; Armbruster, Aaron James; Arnaez, Olivier; Arnal, Vanessa; Arnold, Hannah; Arratia, Miguel; Arslan, Ozan; Artamonov, Andrei; Artoni, Giacomo; Asai, Shoji; Asbah, Nedaa; Ashkenazi, Adi; Åsman, Barbro; Asquith, Lily; Assamagan, Ketevi; Astalos, Robert; Atkinson, Markus; Atlay, Naim Bora; Auerbach, Benjamin; Augsten, Kamil; Aurousseau, Mathieu; Avolio, Giuseppe; Axen, Bradley; Ayoub, Mohamad Kassem; Azuelos, Georges; Baak, Max; Baas, Alessandra; Bacci, Cesare; Bachacou, Henri; Bachas, Konstantinos; Backes, Moritz; Backhaus, Malte; Bagiacchi, Paolo; Bagnaia, Paolo; Bai, Yu; Bain, Travis; Baines, John; Baker, Oliver Keith; Balek, Petr; Balestri, Thomas; Balli, Fabrice; Banas, Elzbieta; Banerjee, Swagato; Bannoura, Arwa A E; Bansil, Hardeep Singh; Barak, Liron; Barberio, Elisabetta Luigia; Barberis, Dario; Barbero, Marlon; Barillari, Teresa; Barisonzi, Marcello; Barklow, Timothy; Barlow, Nick; Barnes, Sarah Louise; Barnett, Bruce; Barnett, Michael; Barnovska, Zuzana; Baroncelli, Antonio; Barone, Gaetano; Barr, Alan; Barreiro, Fernando; Barreiro Guimarães da Costa, João; Bartoldus, Rainer; Barton, Adam Edward; Bartos, Pavol; Basalaev, Artem; Bassalat, Ahmed; Basye, Austin; Bates, Richard; Batista, Santiago Juan; Batley, Richard; Battaglia, Marco; Bauce, Matteo; Bauer, Florian; Bawa, Harinder Singh; Beacham, James Baker; Beattie, Michael David; Beau, Tristan; Beauchemin, Pierre-Hugues; Beccherle, Roberto; Bechtle, Philip; Beck, Hans Peter; Becker, Anne Kathrin; Becker, Maurice; Becker, Sebastian; Beckingham, Matthew; Becot, Cyril; Beddall, Andrew; Beddall, Ayda; Bednyakov, Vadim; Bee, Christopher; Beemster, Lars; Beermann, Thomas; Begel, Michael; Behr, Janna Katharina; Belanger-Champagne, Camille; Bell, William; Bella, Gideon; Bellagamba, Lorenzo; Bellerive, Alain; Bellomo, Massimiliano; Belotskiy, Konstantin; Beltramello, Olga; Benary, Odette; Benchekroun, Driss; Bender, Michael; Bendtz, Katarina; Benekos, Nektarios; Benhammou, Yan; Benhar Noccioli, Eleonora; Benitez Garcia, Jorge-Armando; Benjamin, Douglas; Bensinger, James; Bentvelsen, Stan; Beresford, Lydia; Beretta, Matteo; Berge, David; Bergeaas Kuutmann, Elin; Berger, Nicolas; Berghaus, Frank; Beringer, Jürg; Bernard, Clare; Bernard, Nathan Rogers; Bernius, Catrin; Bernlochner, Florian Urs; Berry, Tracey; Berta, Peter; Bertella, Claudia; Bertoli, Gabriele; Bertolucci, Federico; Bertsche, Carolyn; Bertsche, David; Besana, Maria Ilaria; Besjes, Geert-Jan; Bessidskaia Bylund, Olga; Bessner, Martin Florian; Besson, Nathalie; Betancourt, Christopher; Bethke, Siegfried; Bevan, Adrian John; Bhimji, Wahid; Bianchi, Riccardo-Maria; Bianchini, Louis; Bianco, Michele; Biebel, Otmar; Bieniek, Stephen Paul; Biglietti, Michela; Bilbao De Mendizabal, Javier; Bilokon, Halina; Bindi, Marcello; Binet, Sebastien; Bingul, Ahmet; Bini, Cesare; Black, Curtis; Black, James; Black, Kevin; Blackburn, Daniel; Blair, Robert; Blanchard, Jean-Baptiste; Blanco, Jacobo Ezequiel; Blazek, Tomas; Bloch, Ingo; Blocker, Craig; Blum, Walter; Blumenschein, Ulrike; Bobbink, Gerjan; Bobrovnikov, Victor; Bocchetta, Simona Serena; Bocci, Andrea; Bock, Christopher; Boehler, Michael; Bogaerts, Joannes Andreas; Bogdanchikov, Alexander; Bohm, Christian; Boisvert, Veronique; Bold, Tomasz; Boldea, Venera; Boldyrev, Alexey; Bomben, Marco; Bona, Marcella; Boonekamp, Maarten; Borisov, Anatoly; Borissov, Guennadi; Borroni, Sara; Bortfeldt, Jonathan; Bortolotto, Valerio; Bos, Kors; Boscherini, Davide; Bosman, Martine; Boudreau, Joseph; Bouffard, Julian; Bouhova-Thacker, Evelina Vassileva; Boumediene, Djamel Eddine; Bourdarios, Claire; Bousson, Nicolas; Boveia, Antonio; Boyd, James; Boyko, Igor; Bozic, Ivan; Bracinik, Juraj; Brandt, Andrew; Brandt, Gerhard; Brandt, Oleg; Bratzler, Uwe; Brau, Benjamin; Brau, James; Braun, Helmut; Brazzale, Simone Federico; Brendlinger, Kurt; Brennan, Amelia Jean; Brenner, Lydia; Brenner, Richard; Bressler, Shikma; Bristow, Kieran; Bristow, Timothy Michael; Britton, Dave; Britzger, Daniel; Brochu, Frederic; Brock, Ian; Brock, Raymond; Bronner, Johanna; Brooijmans, Gustaaf; Brooks, Timothy; Brooks, William; Brosamer, Jacquelyn; Brost, Elizabeth; Brown, Jonathan; Bruckman de Renstrom, Pawel; Bruncko, Dusan; Bruneliere, Renaud; Bruni, Alessia; Bruni, Graziano; Bruschi, Marco; Bryngemark, Lene; Buanes, Trygve; Buat, Quentin; Buchholz, Peter; Buckley, Andrew; Buda, Stelian Ioan; Budagov, Ioulian; Buehrer, Felix; Bugge, Lars; Bugge, Magnar Kopangen; Bulekov, Oleg; Bullock, Daniel; Burckhart, Helfried; Burdin, Sergey; Burghgrave, Blake; Burke, Stephen; Burmeister, Ingo; Busato, Emmanuel; Büscher, Daniel; Büscher, Volker; Bussey, Peter; Butler, John; Butt, Aatif Imtiaz; Buttar, Craig; Butterworth, Jonathan; Butti, Pierfrancesco; Buttinger, William; Buzatu, Adrian; Buzykaev, Aleksey; Cabrera Urbán, Susana; Caforio, Davide; Cairo, Valentina; Cakir, Orhan; Calafiura, Paolo; Calandri, Alessandro; Calderini, Giovanni; Calfayan, Philippe; Caloba, Luiz; Calvet, David; Calvet, Samuel; Camacho Toro, Reina; Camarda, Stefano; Camarri, Paolo; Cameron, David; Caminada, Lea Michaela; Caminal Armadans, Roger; Campana, Simone; Campanelli, Mario; Campoverde, Angel; Canale, Vincenzo; Canepa, Anadi; Cano Bret, Marc; Cantero, Josu; Cantrill, Robert; Cao, Tingting; Capeans Garrido, Maria Del Mar; Caprini, Irinel; Caprini, Mihai; Capua, Marcella; Caputo, Regina; Cardarelli, Roberto; Carli, Tancredi; Carlino, Gianpaolo; Carminati, Leonardo; Caron, Sascha; Carquin, Edson; Carrillo-Montoya, German D; Carter, Janet; Carvalho, João; Casadei, Diego; Casado, Maria Pilar; Casolino, Mirkoantonio; Castaneda-Miranda, Elizabeth; Castelli, Angelantonio; Castillo Gimenez, Victoria; Castro, Nuno Filipe; Catastini, Pierluigi; Catinaccio, Andrea; Catmore, James; Cattai, Ariella; Caudron, Julien; Cavaliere, Viviana; Cavalli, Donatella; Cavalli-Sforza, Matteo; Cavasinni, Vincenzo; Ceradini, Filippo; Cerio, Benjamin; Cerny, Karel; Santiago Cerqueira, Augusto; Cerri, Alessandro; Cerrito, Lucio; Cerutti, Fabio; Cerv, Matevz; Cervelli, Alberto; Cetin, Serkant Ali; Chafaq, Aziz; Chakraborty, Dhiman; Chalupkova, Ina; Chang, Philip; Chapleau, Bertrand; Chapman, John Derek; Charlton, Dave; Chau, Chav Chhiv; Chavez Barajas, Carlos Alberto; Cheatham, Susan; Chegwidden, Andrew; Chekanov, Sergei; Chekulaev, Sergey; Chelkov, Gueorgui; Chelstowska, Magda Anna; Chen, Chunhui; Chen, Hucheng; Chen, Karen; Chen, Liming; Chen, Shenjian; Chen, Xin; Chen, Ye; Cheng, Hok Chuen; Cheng, Yangyang; Cheplakov, Alexander; Cheremushkina, Evgenia; Cherkaoui El Moursli, Rajaa; Chernyatin, Valeriy; Cheu, Elliott; Chevalier, Laurent; Chiarella, Vitaliano; Childers, John Taylor; Chiodini, Gabriele; Chisholm, Andrew; Chislett, Rebecca Thalatta; Chitan, Adrian; Chizhov, Mihail; Choi, Kyungeon; Chouridou, Sofia; Chow, Bonnie Kar Bo; Christodoulou, Valentinos; Chromek-Burckhart, Doris; Chu, Ming-Lee; Chudoba, Jiri; Chuinard, Annabelle Julia; Chwastowski, Janusz; Chytka, Ladislav; Ciapetti, Guido; Ciftci, Abbas Kenan; Cinca, Diane; Cindro, Vladimir; Cioara, Irina Antonela; Ciocio, Alessandra; Citron, Zvi Hirsh; Ciubancan, Mihai; Clark, Allan G; Clark, Brian Lee; Clark, Philip James; Clarke, Robert; Cleland, Bill; Clement, Christophe; Coadou, Yann; Cobal, Marina; Coccaro, Andrea; Cochran, James H; Coffey, Laurel; Cogan, Joshua Godfrey; Cole, Brian; Cole, Stephen; Colijn, Auke-Pieter; Collot, Johann; Colombo, Tommaso; Compostella, Gabriele; Conde Muiño, Patricia; Coniavitis, Elias; Connell, Simon Henry; Connelly, Ian; Consonni, Sofia Maria; Consorti, Valerio; Constantinescu, Serban; Conta, Claudio; Conti, Geraldine; Conventi, Francesco; Cooke, Mark; Cooper, Ben; Cooper-Sarkar, Amanda; Cornelissen, Thijs; Corradi, Massimo; Corriveau, Francois; Corso-Radu, Alina; Cortes-Gonzalez, Arely; Cortiana, Giorgio; Costa, Giuseppe; Costa, María José; Costanzo, Davide; Côté, David; Cottin, Giovanna; Cowan, Glen; Cox, Brian; Cranmer, Kyle; Cree, Graham; Crépé-Renaudin, Sabine; Crescioli, Francesco; Cribbs, Wayne Allen; Crispin Ortuzar, Mireia; Cristinziani, Markus; Croft, Vince; Crosetti, Giovanni; Cuhadar Donszelmann, Tulay; Cummings, Jane; Curatolo, Maria; Cuthbert, Cameron; Czirr, Hendrik; Czodrowski, Patrick; D'Auria, Saverio; D'Onofrio, Monica; Da Cunha Sargedas De Sousa, Mario Jose; Da Via, Cinzia; Dabrowski, Wladyslaw; Dafinca, Alexandru; Dai, Tiesheng; Dale, Orjan; Dallaire, Frederick; Dallapiccola, Carlo; Dam, Mogens; Dandoy, Jeffrey Rogers; Dang, Nguyen Phuong; Daniells, Andrew Christopher; Danninger, Matthias; Dano Hoffmann, Maria; Dao, Valerio; Darbo, Giovanni; Darmora, Smita; Dassoulas, James; Dattagupta, Aparajita; Davey, Will; David, Claire; Davidek, Tomas; Davies, Eleanor; Davies, Merlin; Davison, Peter; Davygora, Yuriy; Dawe, Edmund; Dawson, Ian; Daya-Ishmukhametova, Rozmin; De, Kaushik; de Asmundis, Riccardo; De Castro, Stefano; De Cecco, Sandro; De Groot, Nicolo; de Jong, Paul; De la Torre, Hector; De Lorenzi, Francesco; De Nooij, Lucie; De Pedis, Daniele; De Salvo, Alessandro; De Sanctis, Umberto; De Santo, Antonella; De Vivie De Regie, Jean-Baptiste; Dearnaley, William James; Debbe, Ramiro; Debenedetti, Chiara; Dedovich, Dmitri; Deigaard, Ingrid; Del Peso, Jose; Del Prete, Tarcisio; Delgove, David; Deliot, Frederic; Delitzsch, Chris Malena; Deliyergiyev, Maksym; Dell'Acqua, Andrea; Dell'Asta, Lidia; Dell'Orso, Mauro; Della Pietra, Massimo; della Volpe, Domenico; Delmastro, Marco; Delsart, Pierre-Antoine; Deluca, Carolina; DeMarco, David; Demers, Sarah; Demichev, Mikhail; Demilly, Aurelien; Denisov, Sergey; Derendarz, Dominik; Derkaoui, Jamal Eddine; Derue, Frederic; Dervan, Paul; Desch, Klaus Kurt; Deterre, Cecile; Deviveiros, Pier-Olivier; Dewhurst, Alastair; Dhaliwal, Saminder; Di Ciaccio, Anna; Di Ciaccio, Lucia; Di Domenico, Antonio; Di Donato, Camilla; Di Girolamo, Alessandro; Di Girolamo, Beniamino; Di Mattia, Alessandro; Di Micco, Biagio; Di Nardo, Roberto; Di Simone, Andrea; Di Sipio, Riccardo; Di Valentino, David; Diaconu, Cristinel; Diamond, Miriam; Dias, Flavia; Diaz, Marco Aurelio; Diehl, Edward; Dietrich, Janet; Diglio, Sara; Dimitrievska, Aleksandra; Dingfelder, Jochen; Dita, Petre; Dita, Sanda; Dittus, Fridolin; Djama, Fares; Djobava, Tamar; Djuvsland, Julia Isabell; Barros do Vale, Maria Aline; Dobos, Daniel; Dobre, Monica; Doglioni, Caterina; Dohmae, Takeshi; Dolejsi, Jiri; Dolezal, Zdenek; Dolgoshein, Boris; Donadelli, Marisilvia; Donati, Simone; Dondero, Paolo; Donini, Julien; Dopke, Jens; Doria, Alessandra; Dova, Maria-Teresa; Doyle, Tony; Drechsler, Eric; Dris, Manolis; Dubreuil, Emmanuelle; Duchovni, Ehud; Duckeck, Guenter; Ducu, Otilia Anamaria; Duda, Dominik; Dudarev, Alexey; Duflot, Laurent; Duguid, Liam; Dührssen, Michael; Dunford, Monica; Duran Yildiz, Hatice; Düren, Michael; Durglishvili, Archil; Duschinger, Dirk; Dyndal, Mateusz; Eckardt, Christoph; Ecker, Katharina Maria; Edgar, Ryan Christopher; Edson, William; Edwards, Nicholas Charles; Ehrenfeld, Wolfgang; Eifert, Till; Eigen, Gerald; Einsweiler, Kevin; Ekelof, Tord; El Kacimi, Mohamed; Ellert, Mattias; Elles, Sabine; Ellinghaus, Frank; Elliot, Alison; Ellis, Nicolas; Elmsheuser, Johannes; Elsing, Markus; Emeliyanov, Dmitry; Enari, Yuji; Endner, Oliver Chris; Endo, Masaki; Erdmann, Johannes; Ereditato, Antonio; Ernis, Gunar; Ernst, Jesse; Ernst, Michael; Errede, Steven; Ertel, Eugen; Escalier, Marc; Esch, Hendrik; Escobar, Carlos; Esposito, Bellisario; Etienvre, Anne-Isabelle; Etzion, Erez; Evans, Hal; Ezhilov, Alexey; Fabbri, Laura; Facini, Gabriel; Fakhrutdinov, Rinat; Falciano, Speranza; Falla, Rebecca Jane; Faltova, Jana; Fang, Yaquan; Fanti, Marcello; Farbin, Amir; Farilla, Addolorata; Farooque, Trisha; Farrell, Steven; Farrington, Sinead; Farthouat, Philippe; Fassi, Farida; Fassnacht, Patrick; Fassouliotis, Dimitrios; Faucci Giannelli, Michele; Favareto, Andrea; Fayard, Louis; Federic, Pavol; Fedin, Oleg; Fedorko, Wojciech; Feigl, Simon; Feligioni, Lorenzo; Feng, Cunfeng; Feng, Eric; Feng, Haolu; Fenyuk, Alexander; Fernandez Martinez, Patricia; Fernandez Perez, Sonia; Ferrando, James; Ferrari, Arnaud; Ferrari, Pamela; Ferrari, Roberto; Ferreira de Lima, Danilo Enoque; Ferrer, Antonio; Ferrere, Didier; Ferretti, Claudio; Ferretto Parodi, Andrea; Fiascaris, Maria; Fiedler, Frank; Filipčič, Andrej; Filipuzzi, Marco; Filthaut, Frank; Fincke-Keeler, Margret; Finelli, Kevin Daniel; Fiolhais, Miguel; Fiorini, Luca; Firan, Ana; Fischer, Adam; Fischer, Cora; Fischer, Julia; Fisher, Wade Cameron; Fitzgerald, Eric Andrew; Flechl, Martin; Fleck, Ivor; Fleischmann, Philipp; Fleischmann, Sebastian; Fletcher, Gareth Thomas; Fletcher, Gregory; Flick, Tobias; Floderus, Anders; Flores Castillo, Luis; Flowerdew, Michael; Formica, Andrea; Forti, Alessandra; Fournier, Daniel; Fox, Harald; Fracchia, Silvia; Francavilla, Paolo; Franchini, Matteo; Francis, David; Franconi, Laura; Franklin, Melissa; Fraternali, Marco; Freeborn, David; French, Sky; Friedrich, Felix; Froidevaux, Daniel; Frost, James; Fukunaga, Chikara; Fullana Torregrosa, Esteban; Fulsom, Bryan Gregory; Fuster, Juan; Gabaldon, Carolina; Gabizon, Ofir; Gabrielli, Alessandro; Gabrielli, Andrea; Gadatsch, Stefan; Gadomski, Szymon; Gagliardi, Guido; Gagnon, Pauline; Galea, Cristina; Galhardo, Bruno; Gallas, Elizabeth; Gallop, Bruce; Gallus, Petr; Galster, Gorm Aske Gram Krohn; Gan, KK; Gao, Jun; Gao, Yanyan; Gao, Yongsheng; Garay Walls, Francisca; Garberson, Ford; García, Carmen; García Navarro, José Enrique; Garcia-Sciveres, Maurice; Gardner, Robert; Garelli, Nicoletta; Garonne, Vincent; Gatti, Claudio; Gaudiello, Andrea; Gaudio, Gabriella; Gaur, Bakul; Gauthier, Lea; Gauzzi, Paolo; Gavrilenko, Igor; Gay, Colin; Gaycken, Goetz; Gazis, Evangelos; Ge, Peng; Gecse, Zoltan; Gee, Norman; Geerts, Daniël Alphonsus Adrianus; Geich-Gimbel, Christoph; Geisler, Manuel Patrice; Gemme, Claudia; Genest, Marie-Hélène; Gentile, Simonetta; George, Matthias; George, Simon; Gerbaudo, Davide; Gershon, Avi; Ghazlane, Hamid; Giacobbe, Benedetto; Giagu, Stefano; Giangiobbe, Vincent; Giannetti, Paola; Gibbard, Bruce; Gibson, Stephen; Gilchriese, Murdock; Gillam, Thomas; Gillberg, Dag; Gilles, Geoffrey; Gingrich, Douglas; Giokaris, Nikos; Giordani, MarioPaolo; Giorgi, Filippo Maria; Giorgi, Francesco Michelangelo; Giraud, Pierre-Francois; Giromini, Paolo; Giugni, Danilo; Giuliani, Claudia; Giulini, Maddalena; Gjelsten, Børge Kile; Gkaitatzis, Stamatios; Gkialas, Ioannis; Gkougkousis, Evangelos Leonidas; Gladilin, Leonid; Glasman, Claudia; Glatzer, Julian; Glaysher, Paul; Glazov, Alexandre; Goblirsch-Kolb, Maximilian; Goddard, Jack Robert; Godlewski, Jan; Goldfarb, Steven; Golling, Tobias; Golubkov, Dmitry; Gomes, Agostinho; Gonçalo, Ricardo; Goncalves Pinto Firmino Da Costa, Joao; Gonella, Laura; González de la Hoz, Santiago; Gonzalez Parra, Garoe; Gonzalez-Sevilla, Sergio; Goossens, Luc; Gorbounov, Petr Andreevich; Gordon, Howard; Gorelov, Igor; Gorini, Benedetto; Gorini, Edoardo; Gorišek, Andrej; Gornicki, Edward; Goshaw, Alfred; Gössling, Claus; Gostkin, Mikhail Ivanovitch; Goujdami, Driss; Goussiou, Anna; Govender, Nicolin; Grabas, Herve Marie Xavier; Graber, Lars; Grabowska-Bold, Iwona; Grafström, Per; Grahn, Karl-Johan; Gramling, Johanna; Gramstad, Eirik; Grancagnolo, Sergio; Grassi, Valerio; Gratchev, Vadim; Gray, Heather; Graziani, Enrico; Greenwood, Zeno Dixon; Gregersen, Kristian; Gregor, Ingrid-Maria; Grenier, Philippe; Griffiths, Justin; Grillo, Alexander; Grimm, Kathryn; Grinstein, Sebastian; Gris, Philippe Luc Yves; Grivaz, Jean-Francois; Grohs, Johannes Philipp; Grohsjean, Alexander; Gross, Eilam; Grosse-Knetter, Joern; Grossi, Giulio Cornelio; Grout, Zara Jane; Guan, Liang; Guenther, Jaroslav; Guescini, Francesco; Guest, Daniel; Gueta, Orel; Guido, Elisa; Guillemin, Thibault; Guindon, Stefan; Gul, Umar; Gumpert, Christian; Guo, Jun; Gupta, Shaun; Gutierrez, Phillip; Gutierrez Ortiz, Nicolas Gilberto; Gutschow, Christian; Guyot, Claude; Gwenlan, Claire; Gwilliam, Carl; Haas, Andy; Haber, Carl; Hadavand, Haleh Khani; Haddad, Nacim; Haefner, Petra; Hageböck, Stephan; Hajduk, Zbigniew; Hakobyan, Hrachya; Haleem, Mahsana; Haley, Joseph; Hall, David; Halladjian, Garabed; Hallewell, Gregory David; Hamacher, Klaus; Hamal, Petr; Hamano, Kenji; Hamer, Matthias; Hamilton, Andrew; Hamilton, Samuel; Hamity, Guillermo Nicolas; Hamnett, Phillip George; Han, Liang; Hanagaki, Kazunori; Hanawa, Keita; Hance, Michael; Hanke, Paul; Hanna, Remie; Hansen, Jørgen Beck; Hansen, Jorn Dines; Hansen, Maike Christina; Hansen, Peter Henrik; Hara, Kazuhiko; Hard, Andrew; Harenberg, Torsten; Hariri, Faten; Harkusha, Siarhei; Harrington, Robert; Harrison, Paul Fraser; Hartjes, Fred; Hasegawa, Makoto; Hasegawa, Satoshi; Hasegawa, Yoji; Hasib, A; Hassani, Samira; Haug, Sigve; Hauser, Reiner; Hauswald, Lorenz; Havranek, Miroslav; Hawkes, Christopher; Hawkings, Richard John; Hawkins, Anthony David; Hayashi, Takayasu; Hayden, Daniel; Hays, Chris; Hays, Jonathan Michael; Hayward, Helen; Haywood, Stephen; Head, Simon; Heck, Tobias; Hedberg, Vincent; Heelan, Louise; Heim, Sarah; Heim, Timon; Heinemann, Beate; Heinrich, Lukas; Hejbal, Jiri; Helary, Louis; Hellman, Sten; Hellmich, Dennis; Helsens, Clement; Henderson, James; Henderson, Robert; Heng, Yang; Hengler, Christopher; Henrichs, Anna; Henriques Correia, Ana Maria; Henrot-Versille, Sophie; Herbert, Geoffrey Henry; Hernández Jiménez, Yesenia; Herrberg-Schubert, Ruth; Herten, Gregor; Hertenberger, Ralf; Hervas, Luis; Hesketh, Gavin Grant; Hessey, Nigel; Hetherly, Jeffrey Wayne; Hickling, Robert; Higón-Rodriguez, Emilio; Hill, Ewan; Hill, John; Hiller, Karl Heinz; Hillier, Stephen; Hinchliffe, Ian; Hines, Elizabeth; Hinman, Rachel Reisner; Hirose, Minoru; Hirschbuehl, Dominic; Hobbs, John; Hod, Noam; Hodgkinson, Mark; Hodgson, Paul; Hoecker, Andreas; Hoeferkamp, Martin; Hoenig, Friedrich; Hohlfeld, Marc; Hohn, David; Holmes, Tova Ray; Homann, Michael; Hong, Tae Min; Hooft van Huysduynen, Loek; Hopkins, Walter; Horii, Yasuyuki; Horton, Arthur James; Hostachy, Jean-Yves; Hou, Suen; Hoummada, Abdeslam; Howard, Jacob; Howarth, James; Hrabovsky, Miroslav; Hristova, Ivana; Hrivnac, Julius; Hryn'ova, Tetiana; Hrynevich, Aliaksei; Hsu, Catherine; Hsu, Pai-hsien Jennifer; Hsu, Shih-Chieh; Hu, Diedi; Hu, Qipeng; Hu, Xueye; Huang, Yanping; Hubacek, Zdenek; Hubaut, Fabrice; Huegging, Fabian; Huffman, Todd Brian; Hughes, Emlyn; Hughes, Gareth; Huhtinen, Mika; Hülsing, Tobias Alexander; Huseynov, Nazim; Huston, Joey; Huth, John; Iacobucci, Giuseppe; Iakovidis, Georgios; Ibragimov, Iskander; Iconomidou-Fayard, Lydia; Ideal, Emma; Idrissi, Zineb; Iengo, Paolo; Igonkina, Olga; Iizawa, Tomoya; Ikegami, Yoichi; Ikematsu, Katsumasa; Ikeno, Masahiro; Ilchenko, Iurii; Iliadis, Dimitrios; Ilic, Nikolina; Inamaru, Yuki; Ince, Tayfun; Ioannou, Pavlos; Iodice, Mauro; Iordanidou, Kalliopi; Ippolito, Valerio; Irles Quiles, Adrian; Isaksson, Charlie; Ishino, Masaya; Ishitsuka, Masaki; Ishmukhametov, Renat; Issever, Cigdem; Istin, Serhat; Iturbe Ponce, Julia Mariana; Iuppa, Roberto; Ivarsson, Jenny; Iwanski, Wieslaw; Iwasaki, Hiroyuki; Izen, Joseph; Izzo, Vincenzo; Jabbar, Samina; Jackson, Brett; Jackson, Matthew; Jackson, Paul; Jaekel, Martin; Jain, Vivek; Jakobs, Karl; Jakobsen, Sune; Jakoubek, Tomas; Jakubek, Jan; Jamin, David Olivier; Jana, Dilip; Jansen, Eric; Jansky, Roland; Janssen, Jens; Janus, Michel; Jarlskog, Göran; Javadov, Namig; Javůrek, Tomáš; Jeanty, Laura; Jejelava, Juansher; Jeng, Geng-yuan; Jennens, David; Jenni, Peter; Jentzsch, Jennifer; Jeske, Carl; Jézéquel, Stéphane; Ji, Haoshuang; Jia, Jiangyong; Jiang, Yi; Jiggins, Stephen; Jimenez Pena, Javier; Jin, Shan; Jinaru, Adam; Jinnouchi, Osamu; Joergensen, Morten Dam; Johansson, Per; Johns, Kenneth; Jon-And, Kerstin; Jones, Graham; Jones, Roger; Jones, Tim; Jongmanns, Jan; Jorge, Pedro; Joshi, Kiran Daniel; Jovicevic, Jelena; Ju, Xiangyang; Jung, Christian; Jussel, Patrick; Juste Rozas, Aurelio; Kaci, Mohammed; Kaczmarska, Anna; Kado, Marumi; Kagan, Harris; Kagan, Michael; Kahn, Sebastien Jonathan; Kajomovitz, Enrique; Kalderon, Charles William; Kama, Sami; Kamenshchikov, Andrey; Kanaya, Naoko; Kaneda, Michiru; Kaneti, Steven; Kantserov, Vadim; Kanzaki, Junichi; Kaplan, Benjamin; Kapliy, Anton; Kar, Deepak; Karakostas, Konstantinos; Karamaoun, Andrew; Karastathis, Nikolaos; Kareem, Mohammad Jawad; Karnevskiy, Mikhail; Karpov, Sergey; Karpova, Zoya; Karthik, Krishnaiyengar; Kartvelishvili, Vakhtang; Karyukhin, Andrey; Kashif, Lashkar; Kass, Richard; Kastanas, Alex; Kataoka, Yousuke; Katre, Akshay; Katzy, Judith; Kawagoe, Kiyotomo; Kawamoto, Tatsuo; Kawamura, Gen; Kazama, Shingo; Kazanin, Vassili; Kazarinov, Makhail; Keeler, Richard; Kehoe, Robert; Keller, John; Kempster, Jacob Julian; Keoshkerian, Houry; Kepka, Oldrich; Kerševan, Borut Paul; Kersten, Susanne; Keyes, Robert; Khalil-zada, Farkhad; Khandanyan, Hovhannes; Khanov, Alexander; Kharlamov, Alexey; Khoo, Teng Jian; Khovanskiy, Valery; Khramov, Evgeniy; Khubua, Jemal; Kim, Hee Yeun; Kim, Hyeon Jin; Kim, Shinhong; Kim, Young-Kee; Kimura, Naoki; Kind, Oliver Maria; King, Barry; King, Matthew; King, Robert Steven Beaufoy; King, Samuel Burton; Kirk, Julie; Kiryunin, Andrey; Kishimoto, Tomoe; Kisielewska, Danuta; Kiss, Florian; Kiuchi, Kenji; Kivernyk, Oleh; Kladiva, Eduard; Klein, Matthew Henry; Klein, Max; Klein, Uta; Kleinknecht, Konrad; Klimek, Pawel; Klimentov, Alexei; Klingenberg, Reiner; Klinger, Joel Alexander; Klioutchnikova, Tatiana; Klok, Peter; Kluge, Eike-Erik; Kluit, Peter; Kluth, Stefan; Kneringer, Emmerich; Knoops, Edith; Knue, Andrea; Kobayashi, Aine; Kobayashi, Dai; Kobayashi, Tomio; Kobel, Michael; Kocian, Martin; Kodys, Peter; Koffas, Thomas; Koffeman, Els; Kogan, Lucy Anne; Kohlmann, Simon; Kohout, Zdenek; Kohriki, Takashi; Koi, Tatsumi; Kolanoski, Hermann; Koletsou, Iro; Komar, Aston; Komori, Yuto; Kondo, Takahiko; Kondrashova, Nataliia; Köneke, Karsten; König, Adriaan; König, Sebastian; Kono, Takanori; Konoplich, Rostislav; Konstantinidis, Nikolaos; Kopeliansky, Revital; Koperny, Stefan; Köpke, Lutz; Kopp, Anna Katharina; Korcyl, Krzysztof; Kordas, Kostantinos; Korn, Andreas; Korol, Aleksandr; Korolkov, Ilya; Korolkova, Elena; Kortner, Oliver; Kortner, Sandra; Kosek, Tomas; Kostyukhin, Vadim; Kotov, Vladislav; Kotwal, Ashutosh; Kourkoumeli-Charalampidi, Athina; Kourkoumelis, Christine; Kouskoura, Vasiliki; Koutsman, Alex; Kowalewski, Robert Victor; Kowalski, Tadeusz; Kozanecki, Witold; Kozhin, Anatoly; Kramarenko, Viktor; Kramberger, Gregor; Krasnopevtsev, Dimitriy; Krasny, Mieczyslaw Witold; Krasznahorkay, Attila; Kraus, Jana; Kravchenko, Anton; Kreiss, Sven; Kretz, Moritz; Kretzschmar, Jan; Kreutzfeldt, Kristof; Krieger, Peter; Krizka, Karol; Kroeninger, Kevin; Kroha, Hubert; Kroll, Joe; Kroseberg, Juergen; Krstic, Jelena; Kruchonak, Uladzimir; Krüger, Hans; Krumnack, Nils; Krumshteyn, Zinovii; Kruse, Amanda; Kruse, Mark; Kruskal, Michael; Kubota, Takashi; Kucuk, Hilal; Kuday, Sinan; Kuehn, Susanne; Kugel, Andreas; Kuger, Fabian; Kuhl, Andrew; Kuhl, Thorsten; Kukhtin, Victor; Kulchitsky, Yuri; Kuleshov, Sergey; Kuna, Marine; Kunigo, Takuto; Kupco, Alexander; Kurashige, Hisaya; Kurochkin, Yurii; Kurumida, Rie; Kus, Vlastimil; Kuwertz, Emma Sian; Kuze, Masahiro; Kvita, Jiri; Kwan, Tony; Kyriazopoulos, Dimitrios; La Rosa, Alessandro; La Rosa Navarro, Jose Luis; La Rotonda, Laura; Lacasta, Carlos; Lacava, Francesco; Lacey, James; Lacker, Heiko; Lacour, Didier; Lacuesta, Vicente Ramón; Ladygin, Evgueni; Lafaye, Remi; Laforge, Bertrand; Lagouri, Theodota; Lai, Stanley; Lambourne, Luke; Lammers, Sabine; Lampen, Caleb; Lampl, Walter; Lançon, Eric; Landgraf, Ulrich; Landon, Murrough; Lang, Valerie Susanne; Lange, J örn Christian; Lankford, Andrew; Lanni, Francesco; Lantzsch, Kerstin; Laplace, Sandrine; Lapoire, Cecile; Laporte, Jean-Francois; Lari, Tommaso; Lasagni Manghi, Federico; Lassnig, Mario; Laurelli, Paolo; Lavrijsen, Wim; Law, Alexander; Laycock, Paul; Le Dortz, Olivier; Le Guirriec, Emmanuel; Le Menedeu, Eve; LeBlanc, Matthew Edgar; LeCompte, Thomas; Ledroit-Guillon, Fabienne Agnes Marie; Lee, Claire Alexandra; Lee, Shih-Chang; Lee, Lawrence; Lefebvre, Guillaume; Lefebvre, Michel; Legger, Federica; Leggett, Charles; Lehan, Allan; Lehmann Miotto, Giovanna; Lei, Xiaowen; Leight, William Axel; Leisos, Antonios; Leister, Andrew Gerard; Leite, Marco Aurelio Lisboa; Leitner, Rupert; Lellouch, Daniel; Lemmer, Boris; Leney, Katharine; Lenz, Tatjana; Lenzi, Bruno; Leone, Robert; Leone, Sandra; Leonidopoulos, Christos; Leontsinis, Stefanos; Leroy, Claude; Lester, Christopher; Levchenko, Mikhail; Levêque, Jessica; Levin, Daniel; Levinson, Lorne; Levy, Mark; Lewis, Adrian; Leyko, Agnieszka; Leyton, Michael; Li, Bing; Li, Haifeng; Li, Ho Ling; Li, Lei; Li, Liang; Li, Shu; Li, Yichen; Liang, Zhijun; Liao, Hongbo; Liberti, Barbara; Liblong, Aaron; Lichard, Peter; Lie, Ki; Liebal, Jessica; Liebig, Wolfgang; Limbach, Christian; Limosani, Antonio; Lin, Simon; Lin, Tai-Hua; Linde, Frank; Lindquist, Brian Edward; Linnemann, James; Lipeles, Elliot; Lipniacka, Anna; Lisovyi, Mykhailo; Liss, Tony; Lissauer, David; Lister, Alison; Litke, Alan; Liu, Bo; Liu, Dong; Liu, Jian; Liu, Jianbei; Liu, Kun; Liu, Lulu; Liu, Miaoyuan; Liu, Minghui; Liu, Yanwen; Livan, Michele; Lleres, Annick; Llorente Merino, Javier; Lloyd, Stephen; Lo Sterzo, Francesco; Lobodzinska, Ewelina; Loch, Peter; Lockman, William; Loebinger, Fred; Loevschall-Jensen, Ask Emil; Loginov, Andrey; Lohse, Thomas; Lohwasser, Kristin; Lokajicek, Milos; Long, Brian Alexander; Long, Jonathan; Long, Robin Eamonn; Looper, Kristina Anne; Lopes, Lourenco; Lopez Mateos, David; Lopez Paredes, Brais; Lopez Paz, Ivan; Lorenz, Jeanette; Lorenzo Martinez, Narei; Losada, Marta; Loscutoff, Peter; Lösel, Philipp Jonathan; Lou, XinChou; Lounis, Abdenour; Love, Jeremy; Love, Peter; Lu, Nan; Lubatti, Henry; Luci, Claudio; Lucotte, Arnaud; Luehring, Frederick; Lukas, Wolfgang; Luminari, Lamberto; Lundberg, Olof; Lund-Jensen, Bengt; Lynn, David; Lysak, Roman; Lytken, Else; Ma, Hong; Ma, Lian Liang; Maccarrone, Giovanni; Macchiolo, Anna; Macdonald, Calum Michael; Machado Miguens, Joana; Macina, Daniela; Madaffari, Daniele; Madar, Romain; Maddocks, Harvey Jonathan; Mader, Wolfgang; Madsen, Alexander; Maeland, Steffen; Maeno, Tadashi; Maevskiy, Artem; Magradze, Erekle; Mahboubi, Kambiz; Mahlstedt, Joern; Maiani, Camilla; Maidantchik, Carmen; Maier, Andreas Alexander; Maier, Thomas; Maio, Amélia; Majewski, Stephanie; Makida, Yasuhiro; Makovec, Nikola; Malaescu, Bogdan; Malecki, Pawel; Maleev, Victor; Malek, Fairouz; Mallik, Usha; Malon, David; Malone, Caitlin; Maltezos, Stavros; Malyshev, Vladimir; Malyukov, Sergei; Mamuzic, Judita; Mancini, Giada; Mandelli, Beatrice; Mandelli, Luciano; Mandić, Igor; Mandrysch, Rocco; Maneira, José; Manfredini, Alessandro; Manhaes de Andrade Filho, Luciano; Manjarres Ramos, Joany; Mann, Alexander; Manning, Peter; Manousakis-Katsikakis, Arkadios; Mansoulie, Bruno; Mantifel, Rodger; Mantoani, Matteo; Mapelli, Livio; March, Luis; Marchiori, Giovanni; Marcisovsky, Michal; Marino, Christopher; Marjanovic, Marija; Marroquim, Fernando; Marsden, Stephen Philip; Marshall, Zach; Marti, Lukas Fritz; Marti-Garcia, Salvador; Martin, Brian Thomas; Martin, Tim; Martin, Victoria Jane; Martin dit Latour, Bertrand; Martinez, Mario; Martin-Haugh, Stewart; Martoiu, Victor Sorin; Martyniuk, Alex; Marx, Marilyn; Marzano, Francesco; Marzin, Antoine; Masetti, Lucia; Mashimo, Tetsuro; Mashinistov, Ruslan; Masik, Jiri; Maslennikov, Alexey; Massa, Ignazio; Massa, Lorenzo; Massol, Nicolas; Mastrandrea, Paolo; Mastroberardino, Anna; Masubuchi, Tatsuya; Mättig, Peter; Mattmann, Johannes; Maurer, Julien; Maxfield, Stephen; Maximov, Dmitriy; Mazini, Rachid; Mazza, Simone Michele; Mazzaferro, Luca; Mc Goldrick, Garrin; Mc Kee, Shawn Patrick; McCarn, Allison; McCarthy, Robert; McCarthy, Tom; McCubbin, Norman; McFarlane, Kenneth; Mcfayden, Josh; Mchedlidze, Gvantsa; McMahon, Steve; McPherson, Robert; Medinnis, Michael; Meehan, Samuel; Mehlhase, Sascha; Mehta, Andrew; Meier, Karlheinz; Meineck, Christian; Meirose, Bernhard; Mellado Garcia, Bruce Rafael; Meloni, Federico; Mengarelli, Alberto; Menke, Sven; Meoni, Evelin; Mercurio, Kevin Michael; Mergelmeyer, Sebastian; Mermod, Philippe; Merola, Leonardo; Meroni, Chiara; Merritt, Frank; Messina, Andrea; Metcalfe, Jessica; Mete, Alaettin Serhan; Meyer, Carsten; Meyer, Christopher; Meyer, Jean-Pierre; Meyer, Jochen; Middleton, Robin; Miglioranzi, Silvia; Mijović, Liza; Mikenberg, Giora; Mikestikova, Marcela; Mikuž, Marko; Milesi, Marco; Milic, Adriana; Miller, David; Mills, Corrinne; Milov, Alexander; Milstead, David; Minaenko, Andrey; Minami, Yuto; Minashvili, Irakli; Mincer, Allen; Mindur, Bartosz; Mineev, Mikhail; Ming, Yao; Mir, Lluisa-Maria; Mitani, Takashi; Mitrevski, Jovan; Mitsou, Vasiliki A; Miucci, Antonio; Miyagawa, Paul; Mjörnmark, Jan-Ulf; Moa, Torbjoern; Mochizuki, Kazuya; Mohapatra, Soumya; Mohr, Wolfgang; Molander, Simon; Moles-Valls, Regina; Mönig, Klaus; Monini, Caterina; Monk, James; Monnier, Emmanuel; Montejo Berlingen, Javier; Monticelli, Fernando; Monzani, Simone; Moore, Roger; Morange, Nicolas; Moreno, Deywis; Moreno Llácer, María; Morettini, Paolo; Morgenstern, Marcus; Morii, Masahiro; Morinaga, Masahiro; Morisbak, Vanja; Moritz, Sebastian; Morley, Anthony Keith; Mornacchi, Giuseppe; Morris, John; Mortensen, Simon Stark; Morton, Alexander; Morvaj, Ljiljana; Mosidze, Maia; Moss, Josh; Motohashi, Kazuki; Mount, Richard; Mountricha, Eleni; Mouraviev, Sergei; Moyse, Edward; Muanza, Steve; Mudd, Richard; Mueller, Felix; Mueller, James; Mueller, Klemens; Mueller, Ralph Soeren Peter; Mueller, Thibaut; Muenstermann, Daniel; Mullen, Paul; Munwes, Yonathan; Murillo Quijada, Javier Alberto; Murray, Bill; Musheghyan, Haykuhi; Musto, Elisa; Myagkov, Alexey; Myska, Miroslav; Nackenhorst, Olaf; Nadal, Jordi; Nagai, Koichi; Nagai, Ryo; Nagai, Yoshikazu; Nagano, Kunihiro; Nagarkar, Advait; Nagasaka, Yasushi; Nagata, Kazuki; Nagel, Martin; Nagy, Elemer; Nairz, Armin Michael; Nakahama, Yu; Nakamura, Koji; Nakamura, Tomoaki; Nakano, Itsuo; Namasivayam, Harisankar; Naranjo Garcia, Roger Felipe; Narayan, Rohin; Naumann, Thomas; Navarro, Gabriela; Nayyar, Ruchika; Neal, Homer; Nechaeva, Polina; Neep, Thomas James; Nef, Pascal Daniel; Negri, Andrea; Negrini, Matteo; Nektarijevic, Snezana; Nellist, Clara; Nelson, Andrew; Nemecek, Stanislav; Nemethy, Peter; Nepomuceno, Andre Asevedo; Nessi, Marzio; Neubauer, Mark; Neumann, Manuel; Neves, Ricardo; Nevski, Pavel; Newman, Paul; Nguyen, Duong Hai; Nickerson, Richard; Nicolaidou, Rosy; Nicquevert, Bertrand; Nielsen, Jason; Nikiforou, Nikiforos; Nikiforov, Andriy; Nikolaenko, Vladimir; Nikolic-Audit, Irena; Nikolopoulos, Konstantinos; Nilsen, Jon Kerr; Nilsson, Paul; Ninomiya, Yoichi; Nisati, Aleandro; Nisius, Richard; Nobe, Takuya; Nomachi, Masaharu; Nomidis, Ioannis; Nooney, Tamsin; Norberg, Scarlet; Nordberg, Markus; Novgorodova, Olga; Nowak, Sebastian; Nozaki, Mitsuaki; Nozka, Libor; Ntekas, Konstantinos; Nunes Hanninger, Guilherme; Nunnemann, Thomas; Nurse, Emily; Nuti, Francesco; O'Brien, Brendan Joseph; O'grady, Fionnbarr; O'Neil, Dugan; O'Shea, Val; Oakham, Gerald; Oberlack, Horst; Obermann, Theresa; Ocariz, Jose; Ochi, Atsuhiko; Ochoa, Ines; Ochoa-Ricoux, Juan Pedro; Oda, Susumu; Odaka, Shigeru; Ogren, Harold; Oh, Alexander; Oh, Seog; Ohm, Christian; Ohman, Henrik; Oide, Hideyuki; Okamura, Wataru; Okawa, Hideki; Okumura, Yasuyuki; Okuyama, Toyonobu; Olariu, Albert; Olivares Pino, Sebastian Andres; Oliveira Damazio, Denis; Oliver Garcia, Elena; Olszewski, Andrzej; Olszowska, Jolanta; Onofre, António; Onyisi, Peter; Oram, Christopher; Oreglia, Mark; Oren, Yona; Orestano, Domizia; Orlando, Nicola; Oropeza Barrera, Cristina; Orr, Robert; Osculati, Bianca; Ospanov, Rustem; Otero y Garzon, Gustavo; Otono, Hidetoshi; Ouchrif, Mohamed; Ouellette, Eric; Ould-Saada, Farid; Ouraou, Ahmimed; Oussoren, Koen Pieter; Ouyang, Qun; Ovcharova, Ana; Owen, Mark; Owen, Rhys Edward; Ozcan, Veysi Erkcan; Ozturk, Nurcan; Pachal, Katherine; Pacheco Pages, Andres; Padilla Aranda, Cristobal; Pagáčová, Martina; Pagan Griso, Simone; Paganis, Efstathios; Pahl, Christoph; Paige, Frank; Pais, Preema; Pajchel, Katarina; Palacino, Gabriel; Palestini, Sandro; Palka, Marek; Pallin, Dominique; Palma, Alberto; Pan, Yibin; Panagiotopoulou, Evgenia; Pandini, Carlo Enrico; Panduro Vazquez, William; Pani, Priscilla; Panitkin, Sergey; Pantea, Dan; Paolozzi, Lorenzo; Papadopoulou, Theodora; Papageorgiou, Konstantinos; Paramonov, Alexander; Paredes Hernandez, Daniela; Parker, Michael Andrew; Parker, Kerry Ann; Parodi, Fabrizio; Parsons, John; Parzefall, Ulrich; Pasqualucci, Enrico; Passaggio, Stefano; Pastore, Fernanda; Pastore, Francesca; Pásztor, Gabriella; Pataraia, Sophio; Patel, Nikhul; Pater, Joleen; Pauly, Thilo; Pearce, James; Pearson, Benjamin; Pedersen, Lars Egholm; Pedersen, Maiken; Pedraza Lopez, Sebastian; Pedro, Rute; Peleganchuk, Sergey; Pelikan, Daniel; Peng, Haiping; Penning, Bjoern; Penwell, John; Perepelitsa, Dennis; Perez Codina, Estel; Pérez García-Estañ, María Teresa; Perini, Laura; Pernegger, Heinz; Perrella, Sabrina; Peschke, Richard; Peshekhonov, Vladimir; Peters, Krisztian; Peters, Yvonne; Petersen, Brian; Petersen, Troels; Petit, Elisabeth; Petridis, Andreas; Petridou, Chariclia; Petrolo, Emilio; Petrucci, Fabrizio; Pettersson, Nora Emilia; Pezoa, Raquel; Phillips, Peter William; Piacquadio, Giacinto; Pianori, Elisabetta; Picazio, Attilio; Piccaro, Elisa; Piccinini, Maurizio; Pickering, Mark Andrew; Piegaia, Ricardo; Pignotti, David; Pilcher, James; Pilkington, Andrew; Pina, João Antonio; Pinamonti, Michele; Pinfold, James; Pingel, Almut; Pinto, Belmiro; Pires, Sylvestre; Pitt, Michael; Pizio, Caterina; Plazak, Lukas; Pleier, Marc-Andre; Pleskot, Vojtech; Plotnikova, Elena; Plucinski, Pawel; Pluth, Daniel; Poettgen, Ruth; Poggioli, Luc; Pohl, David-leon; Polesello, Giacomo; Policicchio, Antonio; Polifka, Richard; Polini, Alessandro; Pollard, Christopher Samuel; Polychronakos, Venetios; Pommès, Kathy; Pontecorvo, Ludovico; Pope, Bernard; Popeneciu, Gabriel Alexandru; Popovic, Dragan; Poppleton, Alan; Pospisil, Stanislav; Potamianos, Karolos; Potrap, Igor; Potter, Christina; Potter, Christopher; Poulard, Gilbert; Poveda, Joaquin; Pozdnyakov, Valery; Pralavorio, Pascal; Pranko, Aliaksandr; Prasad, Srivas; Prell, Soeren; Price, Darren; Price, Lawrence; Primavera, Margherita; Prince, Sebastien; Proissl, Manuel; Prokofiev, Kirill; Prokoshin, Fedor; Protopapadaki, Eftychia-sofia; Protopopescu, Serban; Proudfoot, James; Przybycien, Mariusz; Ptacek, Elizabeth; Puddu, Daniele; Pueschel, Elisa; Puldon, David; Purohit, Milind; Puzo, Patrick; Qian, Jianming; Qin, Gang; Qin, Yang; Quadt, Arnulf; Quarrie, David; Quayle, William; Queitsch-Maitland, Michaela; Quilty, Donnchadha; Raddum, Silje; Radeka, Veljko; Radescu, Voica; Radhakrishnan, Sooraj Krishnan; Radloff, Peter; Rados, Pere; Ragusa, Francesco; Rahal, Ghita; Rajagopalan, Srinivasan; Rammensee, Michael; Rangel-Smith, Camila; Rauscher, Felix; Rave, Stefan; Ravenscroft, Thomas; Raymond, Michel; Read, Alexander Lincoln; Readioff, Nathan Peter; Rebuzzi, Daniela; Redelbach, Andreas; Redlinger, George; Reece, Ryan; Reeves, Kendall; Rehnisch, Laura; Reisin, Hernan; Relich, Matthew; Rembser, Christoph; Ren, Huan; Renaud, Adrien; Rescigno, Marco; Resconi, Silvia; Rezanova, Olga; Reznicek, Pavel; Rezvani, Reyhaneh; Richter, Robert; Richter, Stefan; Richter-Was, Elzbieta; Ricken, Oliver; Ridel, Melissa; Rieck, Patrick; Riegel, Christian Johann; Rieger, Julia; Rijssenbeek, Michael; Rimoldi, Adele; Rinaldi, Lorenzo; Ristić, Branislav; Ritsch, Elmar; Riu, Imma; Rizatdinova, Flera; Rizvi, Eram; Robertson, Steven; Robichaud-Veronneau, Andree; Robinson, Dave; Robinson, James; Robson, Aidan; Roda, Chiara; Roe, Shaun; Røhne, Ole; Rolli, Simona; Romaniouk, Anatoli; Romano, Marino; Romano Saez, Silvestre Marino; Romero Adam, Elena; Rompotis, Nikolaos; Ronzani, Manfredi; Roos, Lydia; Ros, Eduardo; Rosati, Stefano; Rosbach, Kilian; Rose, Peyton; Rosendahl, Peter Lundgaard; Rosenthal, Oliver; Rossetti, Valerio; Rossi, Elvira; Rossi, Leonardo Paolo; Rosten, Rachel; Rotaru, Marina; Roth, Itamar; Rothberg, Joseph; Rousseau, David; Royon, Christophe; Rozanov, Alexandre; Rozen, Yoram; Ruan, Xifeng; Rubbo, Francesco; Rubinskiy, Igor; Rud, Viacheslav; Rudolph, Christian; Rudolph, Matthew Scott; Rühr, Frederik; Ruiz-Martinez, Aranzazu; Rurikova, Zuzana; Rusakovich, Nikolai; Ruschke, Alexander; Russell, Heather; Rutherfoord, John; Ruthmann, Nils; Ryabov, Yury; Rybar, Martin; Rybkin, Grigori; Ryder, Nick; Saavedra, Aldo; Sabato, Gabriele; Sacerdoti, Sabrina; Saddique, Asif; Sadrozinski, Hartmut; Sadykov, Renat; Safai Tehrani, Francesco; Saimpert, Matthias; Sakamoto, Hiroshi; Sakurai, Yuki; Salamanna, Giuseppe; Salamon, Andrea; Saleem, Muhammad; Salek, David; Sales De Bruin, Pedro Henrique; Salihagic, Denis; Salnikov, Andrei; Salt, José; Salvatore, Daniela; Salvatore, Pasquale Fabrizio; Salvucci, Antonio; Salzburger, Andreas; Sampsonidis, Dimitrios; Sanchez, Arturo; Sánchez, Javier; Sanchez Martinez, Victoria; Sandaker, Heidi; Sandbach, Ruth Laura; Sander, Heinz Georg; Sanders, Michiel; Sandhoff, Marisa; Sandoval, Carlos; Sandstroem, Rikard; Sankey, Dave; Sannino, Mario; Sansoni, Andrea; Santoni, Claudio; Santonico, Rinaldo; Santos, Helena; Santoyo Castillo, Itzebelt; Sapp, Kevin; Sapronov, Andrey; Saraiva, João; Sarrazin, Bjorn; Sasaki, Osamu; Sasaki, Yuichi; Sato, Koji; Sauvage, Gilles; Sauvan, Emmanuel; Savage, Graham; Savard, Pierre; Sawyer, Craig; Sawyer, Lee; Saxon, James; Sbarra, Carla; Sbrizzi, Antonio; Scanlon, Tim; Scannicchio, Diana; Scarcella, Mark; Scarfone, Valerio; Schaarschmidt, Jana; Schacht, Peter; Schaefer, Douglas; Schaefer, Ralph; Schaeffer, Jan; Schaepe, Steffen; Schaetzel, Sebastian; Schäfer, Uli; Schaffer, Arthur; Schaile, Dorothee; Schamberger, R.Dean; Scharf, Veit; Schegelsky, Valery; Scheirich, Daniel; Schernau, Michael; Schiavi, Carlo; Schillo, Christian; Schioppa, Marco; Schlenker, Stefan; Schmidt, Evelyn; Schmieden, Kristof; Schmitt, Christian; Schmitt, Sebastian; Schmitt, Stefan; Schneider, Basil; Schnellbach, Yan Jie; Schnoor, Ulrike; Schoeffel, Laurent; Schoening, Andre; Schoenrock, Bradley Daniel; Schopf, Elisabeth; Schorlemmer, Andre Lukas; Schott, Matthias; Schouten, Doug; Schovancova, Jaroslava; Schramm, Steven; Schreyer, Manuel; Schroeder, Christian; Schuh, Natascha; Schultens, Martin Johannes; Schultz-Coulon, Hans-Christian; Schulz, Holger; Schumacher, Markus; Schumm, Bruce; Schune, Philippe; Schwanenberger, Christian; Schwartzman, Ariel; Schwarz, Thomas Andrew; Schwegler, Philipp; Schwemling, Philippe; Schwienhorst, Reinhard; Schwindling, Jerome; Schwindt, Thomas; Schwoerer, Maud; Sciacca, Gianfranco; Scifo, Estelle; Sciolla, Gabriella; Scuri, Fabrizio; Scutti, Federico; Searcy, Jacob; Sedov, George; Sedykh, Evgeny; Seema, Pienpen; Seidel, Sally; Seiden, Abraham; Seifert, Frank; Seixas, José; Sekhniaidze, Givi; Sekhon, Karishma; Sekula, Stephen; Selbach, Karoline Elfriede; Seliverstov, Dmitry; Semprini-Cesari, Nicola; Serfon, Cedric; Serin, Laurent; Serkin, Leonid; Serre, Thomas; Sessa, Marco; Seuster, Rolf; Severini, Horst; Sfiligoj, Tina; Sforza, Federico; Sfyrla, Anna; Shabalina, Elizaveta; Shamim, Mansoora; Shan, Lianyou; Shang, Ruo-yu; Shank, James; Shapiro, Marjorie; Shatalov, Pavel; Shaw, Kate; Shaw, Savanna Marie; Shcherbakova, Anna; Shehu, Ciwake Yusufu; Sherwood, Peter; Shi, Liaoshan; Shimizu, Shima; Shimmin, Chase Owen; Shimojima, Makoto; Shiyakova, Mariya; Shmeleva, Alevtina; Shoaleh Saadi, Diane; Shochet, Mel; Shojaii, Seyedruhollah; Shrestha, Suyog; Shulga, Evgeny; Shupe, Michael; Shushkevich, Stanislav; Sicho, Petr; Sidiropoulou, Ourania; Sidorov, Dmitri; Sidoti, Antonio; Siegert, Frank; Sijacki, Djordje; Silva, José; Silver, Yiftah; Silverstein, Samuel; Simak, Vladislav; Simard, Olivier; Simic, Ljiljana; Simion, Stefan; Simioni, Eduard; Simmons, Brinick; Simon, Dorian; Simoniello, Rosa; Sinervo, Pekka; Sinev, Nikolai; Siragusa, Giovanni; Sisakyan, Alexei; Sivoklokov, Serguei; Sjölin, Jörgen; Sjursen, Therese; Skinner, Malcolm Bruce; Skottowe, Hugh Philip; Skubic, Patrick; Slater, Mark; Slavicek, Tomas; Slawinska, Magdalena; Sliwa, Krzysztof; Smakhtin, Vladimir; Smart, Ben; Smestad, Lillian; Smirnov, Sergei; Smirnov, Yury; Smirnova, Lidia; Smirnova, Oxana; Smith, Matthew; Smizanska, Maria; Smolek, Karel; Snesarev, Andrei; Snidero, Giacomo; Snyder, Scott; Sobie, Randall; Socher, Felix; Soffer, Abner; Soh, Dart-yin; Solans, Carlos; Solar, Michael; Solc, Jaroslav; Soldatov, Evgeny; Soldevila, Urmila; Solodkov, Alexander; Soloshenko, Alexei; Solovyanov, Oleg; Solovyev, Victor; Sommer, Philip; Song, Hong Ye; Soni, Nitesh; Sood, Alexander; Sopczak, Andre; Sopko, Bruno; Sopko, Vit; Sorin, Veronica; Sosa, David; Sosebee, Mark; Sotiropoulou, Calliope Louisa; Soualah, Rachik; Soueid, Paul; Soukharev, Andrey; South, David; Spagnolo, Stefania; Spalla, Margherita; Spanò, Francesco; Spearman, William Robert; Spettel, Fabian; Spighi, Roberto; Spigo, Giancarlo; Spiller, Laurence Anthony; Spousta, Martin; Spreitzer, Teresa; St Denis, Richard Dante; Staerz, Steffen; Stahlman, Jonathan; Stamen, Rainer; Stamm, Soren; Stanecka, Ewa; Stanescu, Cristian; Stanescu-Bellu, Madalina; Stanitzki, Marcel Michael; Stapnes, Steinar; Starchenko, Evgeny; Stark, Jan; Staroba, Pavel; Starovoitov, Pavel; Staszewski, Rafal; Stavina, Pavel; Steinberg, Peter; Stelzer, Bernd; Stelzer, Harald Joerg; Stelzer-Chilton, Oliver; Stenzel, Hasko; Stern, Sebastian; Stewart, Graeme; Stillings, Jan Andre; Stockton, Mark; Stoebe, Michael; Stoicea, Gabriel; Stolte, Philipp; Stonjek, Stefan; Stradling, Alden; Straessner, Arno; Stramaglia, Maria Elena; Strandberg, Jonas; Strandberg, Sara; Strandlie, Are; Strauss, Emanuel; Strauss, Michael; Strizenec, Pavol; Ströhmer, Raimund; Strom, David; Stroynowski, Ryszard; Strubig, Antonia; Stucci, Stefania Antonia; Stugu, Bjarne; Styles, Nicholas Adam; Su, Dong; Su, Jun; Subramaniam, Rajivalochan; Succurro, Antonella; Sugaya, Yorihito; Suhr, Chad; Suk, Michal; Sulin, Vladimir; Sultansoy, Saleh; Sumida, Toshi; Sun, Siyuan; Sun, Xiaohu; Sundermann, Jan Erik; Suruliz, Kerim; Susinno, Giancarlo; Sutton, Mark; Suzuki, Shota; Suzuki, Yu; Svatos, Michal; Swedish, Stephen; Swiatlowski, Maximilian; Sykora, Ivan; Sykora, Tomas; Ta, Duc; Taccini, Cecilia; Tackmann, Kerstin; Taenzer, Joe; Taffard, Anyes; Tafirout, Reda; Taiblum, Nimrod; Takai, Helio; Takashima, Ryuichi; Takeda, Hiroshi; Takeshita, Tohru; Takubo, Yosuke; Talby, Mossadek; Talyshev, Alexey; Tam, Jason; Tan, Kong Guan; Tanaka, Junichi; Tanaka, Reisaburo; Tanaka, Satoshi; Tanaka, Shuji; Tannenwald, Benjamin Bordy; Tannoury, Nancy; Tapprogge, Stefan; Tarem, Shlomit; Tarrade, Fabien; Tartarelli, Giuseppe Francesco; Tas, Petr; Tasevsky, Marek; Tashiro, Takuya; Tassi, Enrico; Tavares Delgado, Ademar; Tayalati, Yahya; Taylor, Frank; Taylor, Geoffrey; Taylor, Wendy; Teischinger, Florian Alfred; Teixeira Dias Castanheira, Matilde; Teixeira-Dias, Pedro; Temming, Kim Katrin; Ten Kate, Herman; Teng, Ping-Kun; Teoh, Jia Jian; Tepel, Fabian-Phillipp; Terada, Susumu; Terashi, Koji; Terron, Juan; Terzo, Stefano; Testa, Marianna; Teuscher, Richard; Therhaag, Jan; Theveneaux-Pelzer, Timothée; Thomas, Juergen; Thomas-Wilsker, Joshuha; Thompson, Emily; Thompson, Paul; Thompson, Ray; Thompson, Stan; Thomsen, Lotte Ansgaard; Thomson, Evelyn; Thomson, Mark; Thun, Rudolf; Tibbetts, Mark James; Ticse Torres, Royer Edson; Tikhomirov, Vladimir; Tikhonov, Yury; Timoshenko, Sergey; Tiouchichine, Elodie; Tipton, Paul; Tisserant, Sylvain; Todorov, Theodore; Todorova-Nova, Sharka; Tojo, Junji; Tokár, Stanislav; Tokushuku, Katsuo; Tollefson, Kirsten; Tolley, Emma; Tomlinson, Lee; Tomoto, Makoto; Tompkins, Lauren; Toms, Konstantin; Torrence, Eric; Torres, Heberth; Torró Pastor, Emma; Toth, Jozsef; Touchard, Francois; Tovey, Daniel; Trefzger, Thomas; Tremblet, Louis; Tricoli, Alessandro; Trigger, Isabel Marian; Trincaz-Duvoid, Sophie; Tripiana, Martin; Trischuk, William; Trocmé, Benjamin; Troncon, Clara; Trottier-McDonald, Michel; Trovatelli, Monica; True, Patrick; Truong, Loan; Trzebinski, Maciej; Trzupek, Adam; Tsarouchas, Charilaos; Tseng, Jeffrey; Tsiareshka, Pavel; Tsionou, Dimitra; Tsipolitis, Georgios; Tsirintanis, Nikolaos; Tsiskaridze, Shota; Tsiskaridze, Vakhtang; Tskhadadze, Edisher; Tsukerman, Ilya; Tsulaia, Vakhtang; Tsuno, Soshi; Tsybychev, Dmitri; Tudorache, Alexandra; Tudorache, Valentina; Tuna, Alexander Naip; Tupputi, Salvatore; Turchikhin, Semen; Turecek, Daniel; Turra, Ruggero; Turvey, Andrew John; Tuts, Michael; Tykhonov, Andrii; Tylmad, Maja; Tyndel, Mike; Ueda, Ikuo; Ueno, Ryuichi; Ughetto, Michael; Ugland, Maren; Uhlenbrock, Mathias; Ukegawa, Fumihiko; Unal, Guillaume; Undrus, Alexander; Unel, Gokhan; Ungaro, Francesca; Unno, Yoshinobu; Unverdorben, Christopher; Urban, Jozef; Urquijo, Phillip; Urrejola, Pedro; Usai, Giulio; Usanova, Anna; Vacavant, Laurent; Vacek, Vaclav; Vachon, Brigitte; Valderanis, Chrysostomos; Valencic, Nika; Valentinetti, Sara; Valero, Alberto; Valery, Loic; Valkar, Stefan; Valladolid Gallego, Eva; Vallecorsa, Sofia; Valls Ferrer, Juan Antonio; Van Den Wollenberg, Wouter; Van Der Deijl, Pieter; van der Geer, Rogier; van der Graaf, Harry; Van Der Leeuw, Robin; van Eldik, Niels; van Gemmeren, Peter; Van Nieuwkoop, Jacobus; van Vulpen, Ivo; van Woerden, Marius Cornelis; Vanadia, Marco; Vandelli, Wainer; Vanguri, Rami; Vaniachine, Alexandre; Vannucci, Francois; Vardanyan, Gagik; Vari, Riccardo; Varnes, Erich; Varol, Tulin; Varouchas, Dimitris; Vartapetian, Armen; Varvell, Kevin; Vazeille, Francois; Vazquez Schroeder, Tamara; Veatch, Jason; Veloso, Filipe; Velz, Thomas; Veneziano, Stefano; Ventura, Andrea; Ventura, Daniel; Venturi, Manuela; Venturi, Nicola; Venturini, Alessio; Vercesi, Valerio; Verducci, Monica; Verkerke, Wouter; Vermeulen, Jos; Vest, Anja; Vetterli, Michel; Viazlo, Oleksandr; Vichou, Irene; Vickey, Trevor; Vickey Boeriu, Oana Elena; Viehhauser, Georg; Viel, Simon; Vigne, Ralph; Villa, Mauro; Villaplana Perez, Miguel; Vilucchi, Elisabetta; Vincter, Manuella; Vinogradov, Vladimir; Vivarelli, Iacopo; Vives Vaque, Francesc; Vlachos, Sotirios; Vladoiu, Dan; Vlasak, Michal; Vogel, Marcelo; Vokac, Petr; Volpi, Guido; Volpi, Matteo; von der Schmitt, Hans; von Radziewski, Holger; von Toerne, Eckhard; Vorobel, Vit; Vorobev, Konstantin; Vos, Marcel; Voss, Rudiger; Vossebeld, Joost; Vranjes, Nenad; Vranjes Milosavljevic, Marija; Vrba, Vaclav; Vreeswijk, Marcel; Vuillermet, Raphael; Vukotic, Ilija; Vykydal, Zdenek; Wagner, Peter; Wagner, Wolfgang; Wahlberg, Hernan; Wahrmund, Sebastian; Wakabayashi, Jun; Walder, James; Walker, Rodney; Walkowiak, Wolfgang; Wang, Chao; Wang, Fuquan; Wang, Haichen; Wang, Hulin; Wang, Jike; Wang, Jin; Wang, Kuhan; Wang, Rui; Wang, Song-Ming; Wang, Tan; Wang, Xiaoxiao; Wanotayaroj, Chaowaroj; Warburton, Andreas; Ward, Patricia; Wardrope, David Robert; Warsinsky, Markus; Washbrook, Andrew; Wasicki, Christoph; Watkins, Peter; Watson, Alan; Watson, Ian; Watson, Miriam; Watts, Gordon; Watts, Stephen; Waugh, Ben; Webb, Samuel; Weber, Michele; Weber, Stefan Wolf; Webster, Jordan S; Weidberg, Anthony; Weinert, Benjamin; Weingarten, Jens; Weiser, Christian; Weits, Hartger; Wells, Phillippa; Wenaus, Torre; Wengler, Thorsten; Wenig, Siegfried; Wermes, Norbert; Werner, Matthias; Werner, Per; Wessels, Martin; Wetter, Jeffrey; Whalen, Kathleen; Wharton, Andrew Mark; White, Andrew; White, Martin; White, Ryan; White, Sebastian; Whiteson, Daniel; Wickens, Fred; Wiedenmann, Werner; Wielers, Monika; Wienemann, Peter; Wiglesworth, Craig; Wiik-Fuchs, Liv Antje Mari; Wildauer, Andreas; Wilkens, Henric George; Williams, Hugh; Williams, Sarah; Willis, Christopher; Willocq, Stephane; Wilson, Alan; Wilson, John; Wingerter-Seez, Isabelle; Winklmeier, Frank; Winter, Benedict Tobias; Wittgen, Matthias; Wittkowski, Josephine; Wollstadt, Simon Jakob; Wolter, Marcin Wladyslaw; Wolters, Helmut; Wosiek, Barbara; Wotschack, Jorg; Woudstra, Martin; Wozniak, Krzysztof; Wu, Mengqing; Wu, Miles; Wu, Sau Lan; Wu, Xin; Wu, Yusheng; Wyatt, Terry Richard; Wynne, Benjamin; Xella, Stefania; Xu, Da; Xu, Lailin; Yabsley, Bruce; Yacoob, Sahal; Yakabe, Ryota; Yamada, Miho; Yamaguchi, Yohei; Yamamoto, Akira; Yamamoto, Shimpei; Yamanaka, Takashi; Yamauchi, Katsuya; Yamazaki, Yuji; Yan, Zhen; Yang, Haijun; Yang, Hongtao; Yang, Yi; Yao, Liwen; Yao, Weiming; Yasu, Yoshiji; Yatsenko, Elena; Yau Wong, Kaven Henry; Ye, Jingbo; Ye, Shuwei; Yeletskikh, Ivan; Yen, Andy L; Yildirim, Eda; Yorita, Kohei; Yoshida, Rikutaro; Yoshihara, Keisuke; Young, Charles; Young, Christopher John; Youssef, Saul; Yu, David Ren-Hwa; Yu, Jaehoon; Yu, Jiaming; Yu, Jie; Yuan, Li; Yurkewicz, Adam; Yusuff, Imran; Zabinski, Bartlomiej; Zaidan, Remi; Zaitsev, Alexander; Zalieckas, Justas; Zaman, Aungshuman; Zambito, Stefano; Zanello, Lucia; Zanzi, Daniele; Zeitnitz, Christian; Zeman, Martin; Zemla, Andrzej; Zengel, Keith; Zenin, Oleg; Ženiš, Tibor; Zerwas, Dirk; Zhang, Dongliang; Zhang, Fangzhou; Zhang, Jinlong; Zhang, Lei; Zhang, Ruiqi; Zhang, Xueyao; Zhang, Zhiqing; Zhao, Xiandong; Zhao, Yongke; Zhao, Zhengguo; Zhemchugov, Alexey; Zhong, Jiahang; Zhou, Bing; Zhou, Chen; Zhou, Lei; Zhou, Li; Zhou, Ning; Zhu, Cheng Guang; Zhu, Hongbo; Zhu, Junjie; Zhu, Yingchun; Zhuang, Xuai; Zhukov, Konstantin; Zibell, Andre; Zieminska, Daria; Zimine, Nikolai; Zimmermann, Christoph; Zimmermann, Stephanie; Zinonos, Zinonas; Zinser, Markus; Ziolkowski, Michael; Živković, Lidija; Zobernig, Georg; Zoccoli, Antonio; zur Nedden, Martin; Zurzolo, Giovanni; Zwalinski, Lukasz

    2015-08-08

    A search for heavy long-lived multi-charged particles is performed using the ATLAS detector at the LHC. Data collected in 2012 at $\\sqrt{s}$=8 TeV from $pp$ collisions corresponding to an integrated luminosity of $20.3$ fb$^{-1}$ are examined. Particles producing anomalously high ionisation, consistent with long-lived massive particles with electric charges from $|q|=2e$ to $|q|=6e$ are searched for. No signal candidate events are observed, and 95% confidence level cross-section upper limits are interpreted as lower mass limits for a Drell--Yan production model. The mass limits range between 660 and 785 GeV.

  9. Efficient and accurate stereotactic radiotherapy using flattening filter free beams and HexaPOD robotic tables

    DEFF Research Database (Denmark)

    Nielsen, Morten; Hansen, C. R.; Brink, C.

    2016-01-01

    Flattening filter free (FFF) high dose rate beam technique was introduced for brain stereotactic radiosurgery (SRS) and lung Stereotactic Body Radiotherapy (SBRT). Furthermore, a HexaPOD treatment table was introduced for the brain SRS to enable correction of rotational setup errors. 19 filter fl...

  10. The Current Status and Future Directions of Heavy Charged Particle Therapy in Medicine

    Science.gov (United States)

    Levy, Richard P.; Blakely, Eleanor A.; Chu, William T.; Coutrakon, George B.; Hug, Eugen B.; Kraft, Gerhard; Tsujii, Hirohiko

    2009-03-01

    As aggressive, 3D-conformal treatment has become the clearly accepted goal of radiation oncology, heavy charged-particle treatment with protons and heavier ions has concurrently and relentlessly ascended to the forefront. Protons and helium nuclei, with relatively low linear-energy-transfer (LET) properties, have consistently been demonstrated to be beneficial for aggressive (high-dose) local treatment of many types of tumors. Protons have been applied to the majority of solid tumors, and have reached a high degree of general acceptance in radiation oncology after three decades and 55,000 patients treated. However, some 15% to 20% of tumor types have proven resistant to even the most aggressive low-LET irradiation. For these radio-resistant tumors, treatment with heavier ions (e.g., carbon) offers great potential benefit. These high-LET particles have increased relative biological effectiveness (RBE) that reaches its maximum in the Bragg peak. Irradiation with these heavier ions offers the unique combination of excellent 3D-dose distribution and increased RBE. We are presently witnessing several, important parallel developments in particle therapy. Protons will likely continue their exponential growth phase, and more compact design systems will make protons available to a larger patient population—thus becoming the "heavy charged particle of choice" for Cancer Centers with limited financial resources. In parallel, major academic efforts will further advance the field of heavier ion therapy, exploring all opportunities for particle treatment and continuing the search for the ideal particle(s) for specific tumors. The future of ion therapy will be best realized by clinical trials that have ready access to top-quality delivery of both protons and heavier ions that can be accurately shaped for treatment of a specific pathology, and which will permit direct randomized-trial comparison of the effectiveness of the various ions for different diseases. Optimal results

  11. Quality assurance system to correct for errors arising from couch rotation in linac-based stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Brezovich, Ivan A.; Pareek, Prem N.; Plott, W. Eugene; Jennelle, Richard L. S.

    1997-01-01

    Purpose: The purpose of this project was the development of a quality assurance (QA) system that would provide geographically accurate targeting for linac-based stereotactic radiosurgery (LBSR). Methods and Materials: The key component of our QA system is a novel device (Alignment Tool) for expedient measurement of gantry and treatment table excursions (wobble) during rotation. The Alignment Tool replaces the familiar pencil-shaped pointers with a ball pointer that is used with the field light of the accelerator to indicate alignment of beam and target. Wobble is measured prior to each patient treatment and analyzed together with the BRW coordinates of the target by a spreadsheet. The corrections required to compensate for any imprecision are identified, and a printout generated indicating the floor stand coordinates for each couch angle used to place the target at isocenter. Results: The Alignment Tool has an inherent accuracy of measurement better than 0.1 mm. The overall targeting error of our QA method, found by evaluating 177 target simulator films of 55 foci in 40 randomly selected patients, was 0.47 ± 0.23 mm. The Alignment Tool was also valuable during installation of the floor stand and a supplemental collimator for the accelerator. Conclusions: The QA procedure described allows accurate targeting in LBSR, even when couch rotation is imprecise. The Alignment Tool can facilitate the installation of any stereotactic irradiation system, and can be useful for annual QA checks as well as in the installation and commissioning of new accelerators

  12. Radiosurgery for arteriovenous malformations based on magnetic resonance angiography

    International Nuclear Information System (INIS)

    Mehta, Minesh; Kubsad, Shrikant; Petereit, Daniel; Turski, Patrick; Levin, Allan; Kinsella, Timothy

    1993-01-01

    Magnetic Resonance Angiography (MRA) was performed to establish its feasibility, compare it with standard angiography (SA), employ MRA in follow-up and semiquantify AVM flow velocity (FV). A correlative evaluation between flow velocity and response to stereotactic radiosurgery was also attempted. (author). 8 refs., 1 tab

  13. Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage

    International Nuclear Information System (INIS)

    Roper, Justin; Chanyavanich, Vorakarn; Betzel, Gregory; Switchenko, Jeffrey; Dhabaan, Anees

    2015-01-01

    Purpose: To determine the dosimetric effects of rotational errors on target coverage using volumetric modulated arc therapy (VMAT) for multitarget stereotactic radiosurgery (SRS). Methods and Materials: This retrospective study included 50 SRS cases, each with 2 intracranial planning target volumes (PTVs). Both PTVs were planned for simultaneous treatment to 21 Gy using a single-isocenter, noncoplanar VMAT SRS technique. Rotational errors of 0.5°, 1.0°, and 2.0° were simulated about all axes. The dose to 95% of the PTV (D95) and the volume covered by 95% of the prescribed dose (V95) were evaluated using multivariate analysis to determine how PTV coverage was related to PTV volume, PTV separation, and rotational error. Results: At 0.5° rotational error, D95 values and V95 coverage rates were ≥95% in all cases. For rotational errors of 1.0°, 7% of targets had D95 and V95 values 95% for only 63% of the targets. Multivariate analysis showed that PTV volume and distance to isocenter were strong predictors of target coverage. Conclusions: The effects of rotational errors on target coverage were studied across a broad range of SRS cases. In general, the risk of compromised coverage increased with decreasing target volume, increasing rotational error and increasing distance between targets. Multivariate regression models from this study may be used to quantify the dosimetric effects of rotational errors on target coverage given patient-specific input parameters of PTV volume and distance to isocenter.

  14. The Use of Cone Beam Computed Tomography for Image Guided Gamma Knife Stereotactic Radiosurgery: Initial Clinical Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Winnie; Cho, Young-Bin [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Ansell, Steve [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Laperriere, Normand; Ménard, Cynthia; Millar, Barbara-Ann [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Zadeh, Gelareh [Division of Neurosurgery, University of Toronto University Health Network, Toronto Western Hospital, Toronto, Ontario (Canada); Macfeeters-Hamilton Centre for Neuro-oncology, Ontario Cancer Institute, Toronto, Ontario (Canada); Kongkham, Paul; Bernstein, Mark [Division of Neurosurgery, University of Toronto University Health Network, Toronto Western Hospital, Toronto, Ontario (Canada); Jaffray, David A. [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada); Department of Medical Biophysics, University of Toronto, Toronto, Ontario (Canada); Chung, Caroline, E-mail: caroline.chung.md@gmail.com [Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario (Canada)

    2016-09-01

    Purpose: The present study used cone beam computed tomography (CBCT) to measure the inter- and intrafraction uncertainties for intracranial stereotactic radiosurgery (SRS) using the Leksell Gamma Knife (GK). Methods and Materials: Using a novel CBCT system adapted to the GK radiosurgery treatment unit, CBCT images were acquired immediately before and after treatment for each treatment session within the context of a research ethics board–approved prospective clinical trial. Patients were immobilized in the Leksell coordinate frame (LCF) for both volumetric CBCT imaging and GK-SRS delivery. The relative displacement of the patient's skull to the stereotactic reference (interfraction motion) was measured for each CBCT scan. Differences between the pre- and post-treatment CBCT scans were used to determine the intrafraction motion. Results: We analyzed 20 pre- and 17 post-treatment CBCT scans in 20 LCF patients treated with SRS. The mean translational pretreatment setup error ± standard deviation in the left-right, anteroposterior, and craniocaudal directions was −0.19 ± 0.32, 0.06 ± 0.27, and −0.23 ± 0.2 mm, with a maximum of −0.74, −0.53, and −0.68 mm, respectively. After an average time between the pre- and post-treatment CBCT scans of 82 minutes (range 27-170), the mean intrafraction error ± standard deviation for the LCF was −0.03 ± 0.05, −0.03 ± 0.18, and −0.03 ± 0.12 mm in the left-right, anteroposterior, and craniocaudual direction, respectively. Conclusions: Using CBCT on a prototype image guided GK Perfexion unit, we were able to measure the inter- and intrafraction positional changes for GK-SRS using the invasive frame. In the era of image guided radiation therapy, the use of CBCT image guidance for both frame- and non–frame-based immobilization systems could serve as a useful quality assurance tool. Our preliminary measurements can guide the application of achievable thresholds for inter- and intrafraction

  15. The Use of Cone Beam Computed Tomography for Image Guided Gamma Knife Stereotactic Radiosurgery: Initial Clinical Evaluation

    International Nuclear Information System (INIS)

    Li, Winnie; Cho, Young-Bin; Ansell, Steve; Laperriere, Normand; Ménard, Cynthia; Millar, Barbara-Ann; Zadeh, Gelareh; Kongkham, Paul; Bernstein, Mark; Jaffray, David A.; Chung, Caroline

    2016-01-01

    Purpose: The present study used cone beam computed tomography (CBCT) to measure the inter- and intrafraction uncertainties for intracranial stereotactic radiosurgery (SRS) using the Leksell Gamma Knife (GK). Methods and Materials: Using a novel CBCT system adapted to the GK radiosurgery treatment unit, CBCT images were acquired immediately before and after treatment for each treatment session within the context of a research ethics board–approved prospective clinical trial. Patients were immobilized in the Leksell coordinate frame (LCF) for both volumetric CBCT imaging and GK-SRS delivery. The relative displacement of the patient's skull to the stereotactic reference (interfraction motion) was measured for each CBCT scan. Differences between the pre- and post-treatment CBCT scans were used to determine the intrafraction motion. Results: We analyzed 20 pre- and 17 post-treatment CBCT scans in 20 LCF patients treated with SRS. The mean translational pretreatment setup error ± standard deviation in the left-right, anteroposterior, and craniocaudal directions was −0.19 ± 0.32, 0.06 ± 0.27, and −0.23 ± 0.2 mm, with a maximum of −0.74, −0.53, and −0.68 mm, respectively. After an average time between the pre- and post-treatment CBCT scans of 82 minutes (range 27-170), the mean intrafraction error ± standard deviation for the LCF was −0.03 ± 0.05, −0.03 ± 0.18, and −0.03 ± 0.12 mm in the left-right, anteroposterior, and craniocaudual direction, respectively. Conclusions: Using CBCT on a prototype image guided GK Perfexion unit, we were able to measure the inter- and intrafraction positional changes for GK-SRS using the invasive frame. In the era of image guided radiation therapy, the use of CBCT image guidance for both frame- and non–frame-based immobilization systems could serve as a useful quality assurance tool. Our preliminary measurements can guide the application of achievable thresholds for inter- and intrafraction

  16. Stereotactic radiosurgery and fractionated stereotactic radiotherapy for the treatment of acoustic schwannomas: comparative observations of 125 patients treated at one institution

    International Nuclear Information System (INIS)

    Andrews, David W.; Suarez, Oscar; Goldman, H. Warren; Downes, M. Beverly; Bednarz, Greg; Corn, Benjamin W.; Werner-Wasik, Maria; Rosenstock, Jeffrey; Curran, Walter J.

    2001-01-01

    Background: Stereotactic radiosurgery (SRS) and, more recently, fractionated stereotactic radiotherapy (SRT) have been recognized as noninvasive alternatives to surgery for the treatment of acoustic schwannomas. We review our experience of acoustic tumor treatments at one institution using a gamma knife for SRS and the first commercial world installation of a dedicated linac for SRT. Methods: Patients were treated with SRS on the gamma knife or SRT on the linac from October 1994 through August 2000. Gamma knife technique involved a fixed-frame multiple shot/high conformality single treatment, whereas linac technique involved daily conventional fraction treatments involving a relocatable frame, fewer isocenters, and high conformality established by noncoplanar arc beam shaping and differential beam weighting. Results: Sixty-nine patients were treated on the gamma knife, and 56 patients were treated on the linac, with 1 NF-2 patient common to both units. Three patients were lost to follow-up, and in the remaining 122 patients, mean follow-up was 119±67 weeks for SRS patients and 115±96 weeks for SRT patients. Tumor control rates were high (≥97%) for sporadic tumors in both groups but lower for NF-2 tumors in the SRT group. Cranial nerve morbidities were comparably low in both groups, with the exception of functional hearing preservation, which was 2.5-fold higher in patients who received conventional fraction SRT. Conclusion: SRS and SRT represent comparable noninvasive treatments for acoustic schwannomas in both sporadic and NF-2 patient groups. At 1-year follow-up, a significantly higher rate of serviceable hearing preservation was achieved in SRT sporadic tumor patients and may therefore be preferable to alternatives including surgery, SRS, or possibly observation in patients with serviceable hearing

  17. Rare case of malignant craniopharyngioma reactive to adjunctive stereotactic radiotherapy and chemotherapy; Case report and review.

    Science.gov (United States)

    Nomura, Shunsunke; Aihara, Yasuo; Amano, Kosaku; Eguchi, Seiichiro; Chiba, Kentaro; Komori, Takashi; Kawamata, Takakazu

    2018-06-19

    Malignant craniopharyngioma or anaplastic craniopharyngioma was first reported in 1987 by Akachi. It has a malignant clinical and histological feature; remarkably rapid progression, atypical pathology like squamous cell carcinoma and poor prognosis. To date seventeen cases of malignant craniopharyngioma have been reported and of these cases, most were of secondary malignant tumor in nature. With respect to traditional benign craniopharyngioma, adjunctive treatment after gross total removal is not necessary, but in the case of malignant types of the tumor, adjunctive treatment is important. This paper presents the first case of malignant craniopharyngioma reactive to adjunctive Gamma knife stereotactic radiosurgery and chemotherapy. Malignant craniopharyngioma is very rare, and we report Gamma knife stereotactic radiosurgery and chemotherapy (Carboplatine and etoposide chemotherapy), as well as Temozolomide chemotherapy were effective and could control progression of the tumor temporarily. Since adjunctive Gamma knife stereotactic radiosurgery and chemotherapy of malignant craniopharyngioma cases affects follow-up strategies, we propose supporting the need to a revision to the WHO classification regarding malignancy evaluation of craniopharyngioma. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Multiple Coulomb scattering of high-energy heavy charged particle beams used in biology and medicine

    International Nuclear Information System (INIS)

    Wong, M.; Schimmerling, W.; Ludewigt, B.; Phillips, M.; Curtis, S.; Tobias, C.A.

    1987-01-01

    The authors measured lateral displacement and angular distributions of high-energy heavy charged particles emerging from a target at the Lawrence Berkeley Laboratory BEVALAC with beams used in radiobiology experiments. Multiple Coulomb scattering occurring in the target material generally spreads the beam laterally and increases its divergence. The apparatus consists of four sets of position-sensitive semiconductor detectors located along the beam line. Each providing two position signals and one energy signal. The difference between the two position signals is used to determine the particle position in one dimension. The two position signals are constrained to add up to the energy deposition signal in order to reject multiple-particle traversals. The vector directions for the incident and emerging particles are reconstructed in three dimensions from their measured coordinated positions. Lateral and angular distributions are reported for beams of high-energy neon, iron and uranium ions incident on targets of aluminum, cooper, lead and water

  19. TOF for heavy stable particle identification

    International Nuclear Information System (INIS)

    Chang, C.Y.

    1983-01-01

    Searching for heavy stable particle production in a new energy region of hadron-hadron collisions is of fundamental theoretical interest. Observation of such particles produced in high energy collisions would indicate the existence of stable heavy leptons or any massive hadronic system carrying new quantum numbers. Experimentally, evidence of its production has not been found for PP collisions either at FNAL or at the CERN ISR for √S = 23 and 62 GeV respectively. However, many theories beyond the standard model do predict its existence on a mass scale ranging from 50 to a few hundred GeV. If so, it would make a high luminosity TeV collider an extremely ideal hunting ground for searching the production of such a speculated object. To measure the mass of a heavy stable charged particle, one usually uses its time of flight (TOF) and/or dE/dX information. For heavy neutral particle, one hopes it may decay at some later time after its production. Hence a pair of jets or a jet associated with a high P/sub t/ muon originated from some places other than the interacting point (IP) of the colliding beams may be a good signal. In this note, we examine the feasibility of TOF measurement on a heavy stable particle produced in PP collisions at √S = 1 TeV and a luminosity of 10 33 cm -2 sec -1 with a single arm spectrometer pointing to the IP

  20. Results of a Conservative Dose Plan Linear Accelerator-Based Stereotactic Radiosurgery for Pediatric Intracranial Arteriovenous Malformations.

    Science.gov (United States)

    Rajshekhar, Vedantam; Moorthy, Ranjith K; Jeyaseelan, Visalakshi; John, Subhashini; Rangad, Faith; Viswanathan, P N; Ravindran, Paul; Singh, Rabiraja

    2016-11-01

    To evaluate the obliteration rate and clinical outcome following linear accelerator (LINAC)-based stereotactic radiosurgery (SRS) for intracranial arteriovenous malformation (AVM) in pediatric patients (age ≤18 years). Factors associated with the obliteration rate and neurologic complications were studied retrospectively in pediatric patients who underwent LINAC-based SRS for AVM between June 1995 and May 2014. The study cohort comprised 36 males and 33 females, with a median age at the time of SRS of 14 years (range, 7-18 years). The mean AVM volume was 8.5 ± 8.7 cc (range, 0.6-41.8 cc). The median marginal dose of radiation delivered was 15 Gy (range, 9-20 Gy). Magnetic resonance imaging (MRI) demonstrated complete obliteration of the AVM in 44 of the 69 patients (63.8%), at a mean follow up of 27.5 months (range, 12-90 months). On subgroup analysis, 41 of the 53 AVMs of ≤14 cc in volume (77.3%) were obliterated. AVMs with a modified AVM radiosurgery score <1 had significantly shorter obliteration times from the time of SRS (P = .006). On multivariate analysis, the mean marginal dose of radiation delivered to the AVM was the sole significant predictor of obliteration (odds ratio, 1.6; 95% confidence interval, 1 to 2.4). A modest median marginal dose of 15 Gy (16 Gy in the obliterated AVM group vs. 12 Gy in the nonobliterated group) resulted in an obliteration rate of 66.7% after LINAC-based SRS for intracranial AVM, with low rate. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Transverse energy per charged particle in heavy-ion collisions: Role of collective flow

    Science.gov (United States)

    Kumar Tiwari, Swatantra; Sahoo, Raghunath

    2018-03-01

    The ratio of (pseudo)rapidity density of transverse energy and the (pseudo)rapidity density of charged particles, which is a measure of the mean transverse energy per particle, is an important observable in high energy heavy-ion collisions. This ratio reveals information about the mechanism of particle production and the freeze-out criteria. Its collision energy and centrality dependence is almost similar to the chemical freeze-out temperature until top Relativistic Heavy-Ion Collider (RHIC) energy. The Large Hadron Collider (LHC) measurement at √{s_{NN}} = 2.76 TeV brings up new challenges towards understanding the phenomena like gluon saturation and role of collective flow, etc. being prevalent at high energies, which could contribute to the above observable. Statistical Hadron Gas Model (SHGM) with a static fireball approximation has been successful in describing both the centrality and energy dependence until top RHIC energies. However, the SHGM predictions for higher energies lie well below the LHC data. In order to understand this, we have incorporated collective flow in an excluded-volume SHGM (EV-SHGM). Our studies suggest that the collective flow plays an important role in describing E T/ N ch and it could be one of the possible parameters to explain the rise observed in E T/ N ch from RHIC to LHC energies. Predictions are made for E T/ N ch , participant pair normalized-transverse energy per unit rapidity and the Bjorken energy density for Pb+Pb collisions at √{s_{NN}} = 5.02 TeV at the Large Hadron Collider.

  2. Biophysical characterization of a relativistic proton beam for image-guided radiosurgery.

    Science.gov (United States)

    Yu, Zhan; Vanstalle, Marie; La Tessa, Chiara; Jiang, Guo-Liang; Durante, Marco

    2012-07-01

    We measured the physical and radiobiological characteristics of 1 GeV protons for possible applications in stereotactic radiosurgery (image-guided plateau-proton radiosurgery). A proton beam was accelerated at 1 GeV at the Brookhaven National Laboratory (Upton, NY) and a target in polymethyl methacrylate (PMMA) was used. Clonogenic survival was measured after exposures to 1-10 Gy in three mammalian cell lines. Measurements and simulations demonstrate that the lateral scattering of the beam is very small. The lateral dose profile was measured with or without the 20-cm plastic target, showing no significant differences up to 2 cm from the axis A large number of secondary swift protons are produced in the target and this leads to an increase of approximately 40% in the measured dose on the beam axis at 20 cm depth. The relative biological effectiveness at 10% survival level ranged between 1.0 and 1.2 on the beam axis, and was slightly higher off-axis. The very low lateral scattering of relativistic protons and the possibility of using online proton radiography during the treatment make them attractive for image-guided plateau (non-Bragg peak) stereotactic radiosurgery.

  3. Biophysical characterization of a relativistic proton beam for image-guided radiosurgery

    International Nuclear Information System (INIS)

    Yu, Z.; Vanstalle, M.; La Tessa, C.; Durante, M.; Jiang Guoliang

    2012-01-01

    We measured the physical and radiobiological characteristics of 1 GeV protons for possible applications in stereotactic radiosurgery (image-guided plateau-proton radiosurgery). A proton beam was accelerated at 1 GeV at the Brookhaven National Laboratory (Upton, NY) and a target in polymethyl methacrylate (PMMA) was used. Clonogenic survival was measured after exposures to 1-10 Gy in three mammalian cell lines. Measurements and simulations demonstrate that the lateral scattering of the beam is very small. The lateral dose profile was measured with or without the 20-cm plastic target, showing no significant differences up to 2 cm from the axis A large number of secondary swift protons are produced in the target and this leads to an increase of approximately 40% in the measured dose on the beam axis at 20 cm depth. The relative biological effectiveness at 10% survival level ranged between 1.0 and 1.2 on the beam axis, and was slightly higher off-axis. The very low lateral scattering of relativistic protons and the possibility of using online proton radiography during the treatment make them attractive for image-guided plateau (non-Bragg peak) stereotactic radiosurgery. (author)

  4. Parametric curve evaluation of a phototransistor used as detector in stereotactic radiosurgery X-ray beam

    International Nuclear Information System (INIS)

    Lima, Daniela Pontes A.; Santos, Luiz Antonio P.; Santos, Walter M.; Silva Junior, Eronides F. da

    2005-01-01

    Phototransistors have been widely used as detectors for low energy X-rays. However, when they are used in high energy X-rays fields like those generated from linear accelerators (linac), there is a certain loss of sensibility to the ionizing radiation. This damage is cumulative and irreversible. Thus, a correction factor must be applied to its response, which is proportional to the integrated dose. However, it is possible to estimate the correction factor by using the V x I parametric curve of the device. The aim of this work was to develop studies to evaluate and correlate the parametric response curve of a phototransistor with its loss of sensibility after irradiation. An Agilent 4155C semiconductor parameter analyzer was used to trace the parametric curve. X-rays were generated by a 14 MV Primus-Siemens linear accelerator. The results demonstrated that there is a correlation between the integrated dose applied to the phototransistor and the parametric response of the device. Studies are under way to determine how such behavior can provide information for the dosimetric planning in stereotactic radiosurgery. (author)

  5. A deep convolutional neural network-based automatic delineation strategy for multiple brain metastases stereotactic radiosurgery.

    Directory of Open Access Journals (Sweden)

    Yan Liu

    Full Text Available Accurate and automatic brain metastases target delineation is a key step for efficient and effective stereotactic radiosurgery (SRS treatment planning. In this work, we developed a deep learning convolutional neural network (CNN algorithm for segmenting brain metastases on contrast-enhanced T1-weighted magnetic resonance imaging (MRI datasets. We integrated the CNN-based algorithm into an automatic brain metastases segmentation workflow and validated on both Multimodal Brain Tumor Image Segmentation challenge (BRATS data and clinical patients' data. Validation on BRATS data yielded average DICE coefficients (DCs of 0.75±0.07 in the tumor core and 0.81±0.04 in the enhancing tumor, which outperformed most techniques in the 2015 BRATS challenge. Segmentation results of patient cases showed an average of DCs 0.67±0.03 and achieved an area under the receiver operating characteristic curve of 0.98±0.01. The developed automatic segmentation strategy surpasses current benchmark levels and offers a promising tool for SRS treatment planning for multiple brain metastases.

  6. Measurement of dosimetric parameters and dose verification in stereotactic radiosurgery (SRS)

    International Nuclear Information System (INIS)

    Reduan Abdullah; Nik Ruzman Nik Idris; Ahmad Lutfi Yusof; Mazurawati Mohamed

    2013-01-01

    Full-text: The purpose of this study was to measure the dosimetric parameters for small photon beams to be used as input data treatment planning computer system (TPS) and to verify dose calculated by TPS in Stereotactic Radiosurgery (SRS) procedure. The beam data required were Percentage Depth Dose (PDD), Off-axis Ratio (OAR), and Scatter Factor of Relative Output Factor. Small beams of 5 mm to 45 mm diameter circular cone collimators used in SRS were utilized for beam data measurements measured using pinpoint 3D ionization chamber (0.016 cc). For second part of this study, we reported the important quality assurance (QA) procedures before SRS treatment that influenced the dose delivery. These QA procedures consist of measurements on the accuracy in target localization and room laser alignment. The dose calculated to be delivered for treatment was verified using pinpoint 3D ionization chamber and TLD 100H. The mean deviation of measured dose using TLD 100H compared to calculated dose was 3.37 %. Beside that, pinpoint ionization 3D chamber give more accurate results of dose compared to TLD 100H. The measured dose using pinpoint 3D ionization chamber are good agreement with calculated dose by TPS with deviation of 2.17 %. The results are acceptable such as recommended by International Commission on Radiation Units and Measurements (ICRU) Report No. 50 (1993) that dose delivered to the target volume must be within ±5 % error. (author)

  7. Frame-less and mask-less cranial stereotactic radiosurgery: a feasibility study

    International Nuclear Information System (INIS)

    Cervino, Laura I; Pawlicki, Todd; Lawson, Joshua D; Jiang, Steve B

    2010-01-01

    Currently, high-precision delivery in stereotactic radiosurgery (SRS) is achieved via high-precision target localization and rigid patient immobilization. Rigid patient immobilization can result in, however, patient discomfort, which is exacerbated by the long duration of SRS treatments and may induce patient movement. To address this issue, we developed a new SRS technique that is aimed to minimize patient discomfort while maintaining high-precision treatment, based on a less-rigid patient immobilization combined with continuous patient motion monitoring. In this paper, we examine the feasibility of this new technique. An anthropomorphic head phantom is used to check the accuracy of a 3D surface imaging system that provides the monitoring. Volunteers are used to study patient motion inside a new type of head mold that is used for minimal immobilization. Results show that for different couch angles, the difference between the phantom positions recorded by the surface imaging system and by an infrared optical tracking system was within 1 mm in displacements and 1 deg. in rotation. The motion detected by both systems during couch shifts is within 1 mm agreement. The average maximum volunteer head motion in the head mold during the 20 min interval in any direction was 0.7 mm (range: 0.4-1.1 mm). Patient motion due to couch motion was always less than 0.2 mm. We conclude that motion inside the minimally immobilizing head mold is small and can be accurately detected by real-time surface imaging.

  8. Frame-less and mask-less cranial stereotactic radiosurgery: a feasibility study

    Science.gov (United States)

    Cerviño, Laura I.; Pawlicki, Todd; Lawson, Joshua D.; Jiang, Steve B.

    2010-04-01

    Currently, high-precision delivery in stereotactic radiosurgery (SRS) is achieved via high-precision target localization and rigid patient immobilization. Rigid patient immobilization can result in, however, patient discomfort, which is exacerbated by the long duration of SRS treatments and may induce patient movement. To address this issue, we developed a new SRS technique that is aimed to minimize patient discomfort while maintaining high-precision treatment, based on a less-rigid patient immobilization combined with continuous patient motion monitoring. In this paper, we examine the feasibility of this new technique. An anthropomorphic head phantom is used to check the accuracy of a 3D surface imaging system that provides the monitoring. Volunteers are used to study patient motion inside a new type of head mold that is used for minimal immobilization. Results show that for different couch angles, the difference between the phantom positions recorded by the surface imaging system and by an infrared optical tracking system was within 1 mm in displacements and 1° in rotation. The motion detected by both systems during couch shifts is within 1 mm agreement. The average maximum volunteer head motion in the head mold during the 20 min interval in any direction was 0.7 mm (range: 0.4-1.1 mm). Patient motion due to couch motion was always less than 0.2 mm. We conclude that motion inside the minimally immobilizing head mold is small and can be accurately detected by real-time surface imaging.

  9. Cell and tissue kinetics of the subependymal layer in mouse brain following heavy charged particle irradiation

    International Nuclear Information System (INIS)

    Manley, N.B.

    1988-01-01

    The following studies investigate the cellular response and cell population kinetics of the subependymal layer in the mouse brain exposed to heavy charged particle irradiation. Partial brain irradiation with helium and neon ions was confined to one cortex of the brain. Both the irradiated and the unirradiated contralateral cortex showed similar disturbances of the cell and tissue kinetics in the subependymal layers. The irradiated hemisphere exhibited histological damage, whereas the unirradiated side appeared normal histologically. The decrease in the values of the labeling indices 1 week after charged particle irradiation was dose- and ion-dependent. Mitotic indices 1 week after 10 and 25 Gy helium and after 10 Gy neon were the same as those seen in the control mice. Analysis of cell kinetics 1 week after 10 Gy helium and 10 Gy neon irradiation suggests the presence of a progenitor subpopulation that is proliferating with a shorter cell cycle. Comparison of the responses to the different charged particle beams indicates that neon ions are more effective in producing direct cellular damage than the helium ions, but the surviving proliferating cells several divisions later continue to maintain active cell renewal. Based on the 1 week post-irradiation H 3 -TdR labeling indices, a rough estimate of the RBE for neon ions is at least 2.5 when compared to helium ions

  10. Long-term Evaluation of Radiation-Induced Optic Neuropathy After Single-Fraction Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Leavitt, Jacqueline A.; Stafford, Scott L.; Link, Michael J.; Pollock, Bruce E.

    2013-01-01

    Purpose: To determine the long-term risk of radiation-induced optic neuropathy (RION) in patients having single-fraction stereotactic radiosurgery (SRS) for benign skull base tumors. Methods and Materials: Retrospective review of 222 patients having Gamma Knife radiosurgery for benign tumors adjacent to the anterior visual pathway (AVP) between 1991 and 1999. Excluded were patients with prior or concurrent external beam radiation therapy or SRS. One hundred twenty-nine patients (58%) had undergone previous surgery. Tumor types included confirmed World Health Organization grade 1 or presumed cavernous sinus meningioma (n=143), pituitary adenoma (n=72), and craniopharyngioma (n=7). The maximum dose to the AVP was ≤8.0 Gy (n=126), 8.1-10.0 Gy (n=39), 10.1-12.0 Gy (n=47), and >12 Gy (n=10). Results: The mean clinical and imaging follow-up periods were 83 and 123 months, respectively. One patient (0.5%) who received a maximum radiation dose of 12.8 Gy to the AVP developed unilateral blindness 18 months after SRS. The chance of RION according to the maximum radiation dose received by the AVP was 0 (95% confidence interval [CI] 0-3.6%), 0 (95% CI 0-10.7%), 0 (95% CI 0-9.0%), and 10% (95% CI 0-43.0%) for patients receiving ≤8 Gy, 8.1-10.0 Gy, 10.1-12.0 Gy, and >12 Gy, respectively. The overall risk of RION in patients receiving >8 Gy to the AVP was 1.0% (95% CI 0-6.2%). Conclusions: The risk of RION after single-fraction SRS in patients with benign skull base tumors who have no prior radiation exposure is very low if the maximum dose to the AVP is ≤12 Gy. Physicians performing single-fraction SRS should remain cautious when treating lesions adjacent to the AVP, especially when the maximum dose exceeds 10 Gy

  11. Long-term Evaluation of Radiation-Induced Optic Neuropathy After Single-Fraction Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Leavitt, Jacqueline A., E-mail: leavitt.jacqueline@mayo.edu [Department of Ophthalmology, Mayo Clinic and Foundation, Rochester, Minnesota (United States); Stafford, Scott L. [Department of Radiation Oncology, Mayo Clinic and Foundation, Rochester, Minnesota (United States); Link, Michael J. [Department of Neurosurgery, Mayo Clinic and Foundation, Rochester, Minnesota (United States); Pollock, Bruce E. [Department of Radiation Oncology, Mayo Clinic and Foundation, Rochester, Minnesota (United States); Department of Neurosurgery, Mayo Clinic and Foundation, Rochester, Minnesota (United States)

    2013-11-01

    Purpose: To determine the long-term risk of radiation-induced optic neuropathy (RION) in patients having single-fraction stereotactic radiosurgery (SRS) for benign skull base tumors. Methods and Materials: Retrospective review of 222 patients having Gamma Knife radiosurgery for benign tumors adjacent to the anterior visual pathway (AVP) between 1991 and 1999. Excluded were patients with prior or concurrent external beam radiation therapy or SRS. One hundred twenty-nine patients (58%) had undergone previous surgery. Tumor types included confirmed World Health Organization grade 1 or presumed cavernous sinus meningioma (n=143), pituitary adenoma (n=72), and craniopharyngioma (n=7). The maximum dose to the AVP was ≤8.0 Gy (n=126), 8.1-10.0 Gy (n=39), 10.1-12.0 Gy (n=47), and >12 Gy (n=10). Results: The mean clinical and imaging follow-up periods were 83 and 123 months, respectively. One patient (0.5%) who received a maximum radiation dose of 12.8 Gy to the AVP developed unilateral blindness 18 months after SRS. The chance of RION according to the maximum radiation dose received by the AVP was 0 (95% confidence interval [CI] 0-3.6%), 0 (95% CI 0-10.7%), 0 (95% CI 0-9.0%), and 10% (95% CI 0-43.0%) for patients receiving ≤8 Gy, 8.1-10.0 Gy, 10.1-12.0 Gy, and >12 Gy, respectively. The overall risk of RION in patients receiving >8 Gy to the AVP was 1.0% (95% CI 0-6.2%). Conclusions: The risk of RION after single-fraction SRS in patients with benign skull base tumors who have no prior radiation exposure is very low if the maximum dose to the AVP is ≤12 Gy. Physicians performing single-fraction SRS should remain cautious when treating lesions adjacent to the AVP, especially when the maximum dose exceeds 10 Gy.

  12. Stereotactic gamma radiosurgery of brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Tatsuya; Kida, Yoshihisa; Tanaka, Takayuki; Oyama, Hirofumi; Yoshida, Kazuo; Maesawa, Satoshi; Kai, Osamu; Nakamura, Mototoshi; Arahata, Masashige [Komaki City Hospital, Aichi (Japan)

    1996-06-01

    One thousand cases with various head and neck diseases have been treated by gamma radiosurgery at Komaki City Hospital since May 1991. Five hundred and sixty-eight out of 1,000 cases were neoplastic lesions which consisted of 173 cases of neurinoma, 108 of metastatic tumors, 103 of meningioma, 69 of gliomas, 27 of pituitary adenoma, 26 of craniopharyngioma, 13 of pineal tumors, 11 of chordoma, 6 of malignant lymphoma, 5 of hemangioblastoma and so on. The most effective result has been shown in metastatic brain tumors. The complete response (disappearance of the lesion) was obtained in more than 50% of the treated lesions, and the control rate of 85% was maintained for more than 12 months. Next effective results were shown in craniopharyngioma, malignant pineal tumors and malignant lymphoma. There was a group which showed moderate response but no tumor disappearance. Those were pituitary adenoma, acoustic neurinoma, meningioma and chordoma. Gliomas showed less response and even progression of tumor at relatively higher rate. It has been found that malignant gliomas showed difficult control of the tumor and progression rate of 70%, while benign gliomas showed the control rate of more than 90%. Besides intracranial lesions, malignant skull base tumors such as chordoma, naso-pharyngeal cancer, adenoid cystic cancer showed better response to gamma radiosurgery and higher control rate for longer period of time with high QOL compaired to conventional irradiation. (author)

  13. Effects of target size on the comparison of photon and charged particle dose distributions

    International Nuclear Information System (INIS)

    Phillips, M.H.; Frankel, K.A.; Tjoa, T.; Lyman, J.T.; Fabrikant, J.I.; Levy, R.P.

    1989-12-01

    The work presented here is part of an ongoing project to quantify and evaluate the differences in the use of different radiation types and irradiation geometries in radiosurgery. We are examining dose distributions for photons using the ''Gamma Knife'' and the linear accelerator arc methods, as well as different species of charged particles from protons to neon ions. A number of different factors need to be studied to accurately compare the different modalities such as target size, shape and location, the irradiation geometry, and biological response. This presentation focuses on target size, which has a large effect on the dose distributions in normal tissue surrounding the lesion. This work concentrates on dose distributions found in radiosurgery, as opposed to those usually found in radiotherapy. 5 refs., 2 figs

  14. Immediate side effects of stereotactic radiotherapy and radiosurgery

    International Nuclear Information System (INIS)

    Werner-Wasik, Maria; Rudoler, Shari; Preston, Peter E.; Downes, Beverly M.; Andrews, David; Corn, Benjamin W.; Rosenstock, Jeffrey; Curran, Walter J.

    1996-01-01

    Purpose/Objective: Despite increased utilization of fractionated stereotactic radiation therapy (SRT) or stereotactic radiosurgery (SRS), the incidence and nature of immediate side effects (ISE) associated with these treatment techniques is not well defined. Materials and Methods: Intracranial lesions in 78 adult patients were treated with SRT or SRS, using a dedicated linear accelerator. They comprised 13 gliomas, 2 ependymomas, 19 metastatic tumors, 15 meningiomas, 12 acoustic neuromas, 4 pituitary adenomas, 1 optic neuroma, 1 chondrosarcoma and 11 arteriovenous malformations (AVM). SRT was used in 51 and SRS in 27 patients. Mean target volume was 9.0 cc. Eleven patients received prior external beam radiation therapy within 2 months before SRT/SRS. Any side effects occurring during and up to two weeks after radiation course were defined as ISE and were graded as mild, moderate or severe. The incidence of ISE and the significance of their association with several pretreatment variables were analyzed. Results: Overall, (28(78)) (35%) patients experienced one or more ISE. Most of ISE (87%) were mild and consisted of nausea (5), dizziness/vertigo (5), seizures (7) and new persistent headaches (17). Two episodes of worsening neurological deficit and 2 of orbital pain were graded as moderate. Two patients experienced severe ISE, requiring hospitalization (1 seizure and 1 worsening neurological deficit). ISE in 5 cases prompted computerized tomography of the brain which revealed increased perilesional edema in 3 cases. The incidence of ISE by diagnosis was as follows: 46% ((6(13))) for gliomas, 50% ((6(12))) for acoustic neuromas, 36% ((4(11))) for AVM, 33% ((5(15))) for meningiomas and 21% ((4(19))) for metastases. Increasing dose to the margin and increasing maximum dose were associated with a higher incidence of ISE (p=0.02 and 0.005, respectively). Prior recent conventional external beam radiation therapy, target volume, number of isocenters, collimator size, dose

  15. The safety and efficacy of robotic image-guided radiosurgery system treatment for intra- and extracranial lesions: A systematic review of the literature

    International Nuclear Information System (INIS)

    Calcerrada Diaz-Santos, Nieves; Blasco Amaro, Juan Antonio; Cardiel, Gloria Ariza; Andradas Aragones, Elena

    2008-01-01

    Background: The CyberKnife is a new, frameless stereotactic radiosurgery system. This work reviews its safety and efficacy in the treatment of intra- and extracranial lesions. Methods: A literature search was made of the Medline, Embase, Pascal Biomed, CINAHL and Cancerlit databases. Health technology assessment reports on stereotactic radiosurgery systems were also consulted. All searches were made in June 2007. Data on efficacy and safety were extracted and then synthesized into the present review. Results: Thirty five clinical studies were identified, the majority of which included no patient comparison group. These studies assessed the use of the CyberKnife mainly in the treatment of primary and metastatic intracranial and spinal tumours. Conclusions: The CyberKnife system allows to carry out standard radiosurgical and fractionated stereotactic radiotherapy procedures. The use of this system offers an alternative for the treatment of inoperable tumours, and of lesions located close to critical structures that cannot be treated using other types of stereotactic radiosurgery system. Unfortunately, the quality of the reviewed papers still does not allow definite conclusions to be drawn regarding the safety and efficacy of these treatments

  16. Stereotactic radiosurgery improves the survival in patients with solitary brain metastasis: a reasonable alternative to surgery

    International Nuclear Information System (INIS)

    Kwan, H. Cho; Hall, Walter A.; Lee, Andrew K.; Gerbi, Bruce J.; Higgins, Patrick D.; Nussbaum, Eric S.; Chung, K.K. Lee; Bohen, Marva; Clark, H. Brent

    1996-01-01

    Purpose: To evaluate the efficacy of stereotactic radiosurgery (SRS) in patients with solitary brain metastasis from extracranial primary cancer and to compare the outcome with that of external whole brain irradiation with or without surgical resection. Materials and Methods: Between September 1970 and November, 1995, 231 patients with solitary brain metastasis were treated at the Department of Radiation Oncology, University of Minnesota Hospital. One hundred twenty six patients (56%) were treated with external whole brain irradiation (WBI) only (Group 1), seventy three (32%) underwent surgical resection prior to WBI (Group 2) and thirty two (14%) underwent stereotactic radiosurgery (SRS) with WBI (Group 3). Lung (38%) was the most common site of primary cancer, followed by breast (15%), unknown primary (12%), gastro-intestinal tract (10%), skin (malignant melanoma: 9%), kidney (renal cell carcinoma: 8%) and others (9%). The median dose to the whole brain was 3750 cGy in 15 fractions (ranges from 2000 cGy to 5000 cGy). The median radiosurgical dose of 17.5 Gy (range, 12-40 Gy) was delivered to the 40%-90% isodose line encompassing the target. Eighteen patients were treated with SRS for recurrent or persistent disease following WBI and 14 patients received SRS as a boost in conjunction with WBI. Actuarial survival was calculated from the date of treatment according to the Kaplan-Meier method and statistical significance was assessed with the log-rank test. Results: The actuarial median survivals were 3.8 months for Group 1 (ranges from 1 to 84 months), 10.5 months for Group 2 (ranges from 1 to 125 months) and 9.8 months for Group 3 (ranges from 1 to 36 months). The survivals at one and two years were 19% and 6% for Group 1, 47% and 19% for Group 2, and 44% and 21% for Group 3, respectively. The survival advantage of Groups 2 or 3 over Group 1 was statistically significant (p < 0.0001 by log-rank test). There was no survival advantage of surgery (Group 2) over SRS

  17. SU-D-BRA-03: Analysis of Systematic Errors with 2D/3D Image Registration for Target Localization and Treatment Delivery in Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Xu, H; Chetty, I; Wen, N

    2016-01-01

    Purpose: Determine systematic deviations between 2D/3D and 3D/3D image registrations with six degrees of freedom (6DOF) for various imaging modalities and registration algorithms on the Varian Edge Linac. Methods: The 6DOF systematic errors were assessed by comparing automated 2D/3D (kV/MV vs. CT) with 3D/3D (CBCT vs. CT) image registrations from different imaging pairs, CT slice thicknesses, couch angles, similarity measures, etc., using a Rando head and a pelvic phantom. The 2D/3D image registration accuracy was evaluated at different treatment sites (intra-cranial and extra-cranial) by statistically analyzing 2D/3D pre-treatment verification against 3D/3D localization of 192 Stereotactic Radiosurgery/Stereotactic Body Radiation Therapy treatment fractions for 88 patients. Results: The systematic errors of 2D/3D image registration using kV-kV, MV-kV and MV-MV image pairs using 0.8 mm slice thickness CT images were within 0.3 mm and 0.3° for translations and rotations with a 95% confidence interval (CI). No significant difference between 2D/3D and 3D/3D image registrations (P>0.05) was observed for target localization at various CT slice thicknesses ranging from 0.8 to 3 mm. Couch angles (30, 45, 60 degree) did not impact the accuracy of 2D/3D image registration. Using pattern intensity with content image filtering was recommended for 2D/3D image registration to achieve the best accuracy. For the patient study, translational error was within 2 mm and rotational error was within 0.6 degrees in terms of 95% CI for 2D/3D image registration. For intra-cranial sites, means and std. deviations of translational errors were −0.2±0.7, 0.04±0.5, 0.1±0.4 mm for LNG, LAT, VRT directions, respectively. For extra-cranial sites, means and std. deviations of translational errors were - 0.04±1, 0.2±1, 0.1±1 mm for LNG, LAT, VRT directions, respectively. 2D/3D image registration uncertainties for intra-cranial and extra-cranial sites were comparable. Conclusion: The Varian

  18. SU-D-BRA-03: Analysis of Systematic Errors with 2D/3D Image Registration for Target Localization and Treatment Delivery in Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Xu, H [Wayne State University, Detroit, MI (United States); Chetty, I; Wen, N [Henry Ford Health System, Detroit, MI (United States)

    2016-06-15

    Purpose: Determine systematic deviations between 2D/3D and 3D/3D image registrations with six degrees of freedom (6DOF) for various imaging modalities and registration algorithms on the Varian Edge Linac. Methods: The 6DOF systematic errors were assessed by comparing automated 2D/3D (kV/MV vs. CT) with 3D/3D (CBCT vs. CT) image registrations from different imaging pairs, CT slice thicknesses, couch angles, similarity measures, etc., using a Rando head and a pelvic phantom. The 2D/3D image registration accuracy was evaluated at different treatment sites (intra-cranial and extra-cranial) by statistically analyzing 2D/3D pre-treatment verification against 3D/3D localization of 192 Stereotactic Radiosurgery/Stereotactic Body Radiation Therapy treatment fractions for 88 patients. Results: The systematic errors of 2D/3D image registration using kV-kV, MV-kV and MV-MV image pairs using 0.8 mm slice thickness CT images were within 0.3 mm and 0.3° for translations and rotations with a 95% confidence interval (CI). No significant difference between 2D/3D and 3D/3D image registrations (P>0.05) was observed for target localization at various CT slice thicknesses ranging from 0.8 to 3 mm. Couch angles (30, 45, 60 degree) did not impact the accuracy of 2D/3D image registration. Using pattern intensity with content image filtering was recommended for 2D/3D image registration to achieve the best accuracy. For the patient study, translational error was within 2 mm and rotational error was within 0.6 degrees in terms of 95% CI for 2D/3D image registration. For intra-cranial sites, means and std. deviations of translational errors were −0.2±0.7, 0.04±0.5, 0.1±0.4 mm for LNG, LAT, VRT directions, respectively. For extra-cranial sites, means and std. deviations of translational errors were - 0.04±1, 0.2±1, 0.1±1 mm for LNG, LAT, VRT directions, respectively. 2D/3D image registration uncertainties for intra-cranial and extra-cranial sites were comparable. Conclusion: The Varian

  19. Stereotactic Radiosurgery for Brainstem Metastases: An International Cooperative Study to Define Response and Toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Trifiletti, Daniel M., E-mail: daniel.trifiletti@gmail.com [Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia (United States); Lee, Cheng-Chia [Department of Neurosurgery, Neurological Institute, Taipei Veteran General Hospital, Taipei, Taiwan (China); Kano, Hideyuki; Cohen, Jonathan [Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania (United States); Janopaul-Naylor, James; Alonso-Basanta, Michelle; Lee, John Y.K. [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Simonova, Gabriela; Liscak, Roman [Department of Radiation and Stereotactic Neurosurgery, Na Homolce Hospital, Prague (Czech Republic); Wolf, Amparo; Kvint, Svetlana [Department of Neurosurgery, New York University Lagone Medical Center, New York, New York (United States); Grills, Inga S.; Johnson, Matthew [Department of Radiation Oncology, Beaumont Health System, Royal Oak, Michigan (United States); Liu, Kang-Du; Lin, Chung-Jung [Department of Neurosurgery, Neurological Institute, Taipei Veteran General Hospital, Taipei, Taiwan (China); Mathieu, David; Héroux, France [Division of Neurosurgery, Université de Sherbrooke, Centre de recherche du CHUS, Sherbrooke, Québec (Canada); Silva, Danilo; Sharma, Mayur [Department of Neurosurgery, Cleveland Clinic, Cleveland, Ohio (United States); Cifarelli, Christopher P. [Departments of Neurosurgery and Radiation Oncology, West Virginia University, Morgantown, West Virginia (United States); and others

    2016-10-01

    Purpose: To pool data across multiple institutions internationally and report on the cumulative experience of brainstem stereotactic radiosurgery (SRS). Methods and Materials: Data on patients with brainstem metastases treated with SRS were collected through the International Gamma Knife Research Foundation. Clinical, radiographic, and dosimetric characteristics were compared for factors prognostic for local control (LC) and overall survival (OS) using univariate and multivariate analyses. Results: Of 547 patients with 596 brainstem metastases treated with SRS, treatment of 7.4% of tumors resulted in severe SRS-induced toxicity (grade ≥3, increased odds with increasing tumor volume, margin dose, and whole-brain irradiation). Local control at 12 months after SRS was 81.8% and was improved with increasing margin dose and maximum dose. Overall survival at 12 months after SRS was 32.7% and impacted by age, gender, number of metastases, tumor histology, and performance score. Conclusions: Our study provides additional evidence that SRS has become an option for patients with brainstem metastases, with an excellent benefit-to-risk ratio in the hands of experienced clinicians. Prior whole-brain irradiation increases the risk of severe toxicity in brainstem metastasis patients undergoing SRS.

  20. Exposure to heavy charged particles affects thermoregulation in rats

    International Nuclear Information System (INIS)

    Kandasamy, S.B.; Hunt, W.A.; Dalton, T.K.; Joseph, J.A.; Harris, A.H.; Rabin, B.M.

    1994-01-01

    Rats exposed to 0.1-5 Gy of heavy particles ( 56 Fe, 40 Ar, 20 Ne or 4 He) showed dose-dependent changes in body temperature. Lower doses of all particles produced hyperthermia, and higher doses of 20 Ne and 56 Fe produced hypothermia. Of the four HZE particles, 56 Fe particles were the most potent and 4 He particles were the least potent in producing changes in thermoregulation. The 20 Ne and 40 Ar particles produced an intermediate level of change in body temperature. Significantly greater hyperthermia was produced by exposure to 1 Gy of 20 Ne, 40 Ar and 56 Fe particles than by exposure to 1 Gy of 60 Co γ rays. Pretreating rats with the cyclo-oxygenase inhibitor indomethacin attenuated the hyperthermia produced by exposure to 1 Gy of 56 Fe particles, indicating that prostaglandins mediate 56 Fe-particle-induced hyperthermia. The hypothermia produced by exposure to 5 Gy of 56 Fe particles is mediated by histamine and can be attenuated by treatment with the antihistamines mepyramine and cimetidine. 15 refs., 4 figs

  1. Experimental measurements of spatial dose distributions in radiosurgery treatments

    International Nuclear Information System (INIS)

    Avila-Rodriguez, M. A.; Rodriguez-Villafuerte, M.; Diaz-Perches, R.; Perez-Pastenes, M. A.

    2001-01-01

    The measurement of stereotactic radiosurgery dose distributions requires an integrating, high-resolution dosimeter capable of providing a spatial map of absorbed dose. This paper describes the use of a commercial radiochromic dye film (GafChromic MD-55-2) to measure radiosurgery dose distributions with 6 MV X-rays in a head phantom. The response of the MD-55-2 was evaluated by digitizing and analyzing the films with conventional computer systems. Radiosurgery dose distributions were measured using the radiochromic film in a spherical acrylic phantom of 16 cm diameter undergoing a typical SRS treatment as a patient, and were compared with dose distributions provided by the treatment planning system. The comparison lead to mean radial differences of ±0.6 mm, ±0.9 mm, ±1.3 mm, ±1.9 mm, and ±2.8 mm, for the 80, 60, 50, 40, and 30% isodose curves, respectively. It is concluded that the radiochromic film is a convenient and useful tool for radiosurgery treatment planning validation

  2. Microsurgical resection of incompletely obliterated intracranial arteriovenous malformations following stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Chang, S.D.; Steinberg, G.K.; Levy, R.P.; Marks, M.P.; Frankel, K.A.; Shuster, D.L.; Marcellus, M.L.

    1998-01-01

    Radiosurgery is effective in obliterating small arteriovenous malformations (AVMs), but less successful in thrombosing larger AVMs. This study reviewed patients who underwent surgical resection of their large AVMs following failed radiosurgical obliteration. AVMs from 36 patients (aged 7 to 64 years, mean 29.9) were surgically resected 1 to 11 years after radiosurgery. Initial AVM volumes were 0.7 to 117 cm 3 (mean 21.6 cm 3 ), and radiosurgical doses ranged from 4.6 to 45 Gray equivalent (GyE) (mean 21.1 GyE). Thirty AVMs (83%) were located in eloquent tissue. Venous drainage was deep (14), superficial (13), or both (9). Spetzler grades were II (2), III (12), IV (18), and V (4). Nine patients suffered rehemorrhage after radiosurgery but prior to surgery, while three patients developed radiation necrosis. Twenty-seven patients underwent endovascular embolization prior to surgery. During microsurgical resection, the AVMs were found to be significantly less vascular and more easily resected, compared to AVMs in patients who had not received radiosurgery. Histology showed endothelial proliferation with hyaline and mineralization in vessel walls. Partial or complete thrombosis of some AVM vessels, and evidence of vessel and brain necrosis were noted in many cases. Clinical outcome was excellent or good in 34 cases, with two patients dying of rebleeding from residual AVM. Five patients were neurologically worse following microsurgical resection. Final outcome was largely related to the pretreatment grade. Radiosurgery several years prior to surgical resection appears useful in treating unusually large and complex AVMs. (author)

  3. Extracranial doses during stereotactic radiosurgery and fractionated stereotactic radiotherapy measured with thermoluminescent dosimeter in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Kim, I.H.; Lim, D.H.; Kim, S.; Hong, S.; Kim, B.K.; Kang, W-S.; Wu, H.G.; Ha, S.W.; Park, C.I. [Seoul National University College of Medicine, Department of Therapeutic Radiology (Korea)

    2000-05-01

    Recently the usage of 3-dimensional non-coplanar radiotherapy technique is increasing. We measured the extracranial dose and its distribution g the above medical procedures to estimate effect of exit doses of stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (FSRT) of the intracranial target lesions using a linac system developed in our hospital. Among over hundred patients who were treated with SRS or FSRT from 1995 to 1998, radiation dosimetry data of 15 cases with SRS and 20 cases with FSRT were analyzed. All patients were adults. Of SRS cases, 11 were male and 4 were female. Vascular malformation cases were 9, benign tumors were 3, and malignant tumors were 3. Of FSRT cases, males were 12 and females were 8. Primary malignant brain tumors were 5, benign tumors were 6, and metastatic brain tumors were 10. Doses were measured with lithium fluoride TLD chips (7.5% Li-6 and 92.5% Li-7; TLD-100, Harshaw/Filtrol, USA). The chips were attached patient's skin at the various extracranial locations during SRS or FSRT. For SRS, 14-25 Gy were delivered with 1-2 isocenters using 12-38 mm circular tertiary collimators with reference to 50-80% isodose line conforming at the periphery of the target lesions. For FSRT, 5-28 fractions were used to deliver 9-56 Gy to periphery with dose maximum of 10-66 Gy. Both procedures used 6 MV X-ray generated from Clinac-18 (Varian, USA). For SRS procedures, extracranial surface doses (relative doses) were 8.07{+-}4.27 Gy (0.31{+-}0.16% Mean{+-}S.D.) at the upper eyelids, 6.13{+-}4.32 Gy (0.24{+-}0.16%) at the submental jaw, 7.80{+-}5.44 Gy (0.33{+-}0.26%) at thyroid, 1.78{+-}0.64 Gy (0.07{+-}0.02%) at breast, 0.75{+-}0.38 Gy (0.03{+-}0.02%) at umbilicus, 0.40{+-}0.07 Gy (0.02{+-}0.01%) at perineum, and 0.46{+-}0.39 Gy (0.02{+-}0.01%) at scrotum. Thus the farther the distance from the brain, the less the dose to the location. In overall the doses were less than 0.3% and thus less detrimental. For FSRT procedures

  4. Initial clinical results of linac stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) for pituitary adenomas

    International Nuclear Information System (INIS)

    Mitsumori, Michihide; Shrieve, Dennis C.; Alexander, Eben; Kaiser, Ursula B.; Richardson, Gary E.; McL Black, Peter; Loeffler, Jay S.

    1997-01-01

    Purpose: To evaluate the initial clinical results of stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (SRT) for pituitary adenomas with regard to tumor control and toxicity of the treatment, thus evaluate the feasibility of these technique for the treatment of pituitary adenomas. Subjects and Methods: 48 patients with either inoperable, recurrent or residual pituitary adenoma who underwent either SRS or SRT at the Brigham and Women's Hospital between 9/89 and 9/95 were analyzed. Of these, 18 received treatment with SRS, and 30 received SRT. SRS was contraindicated for the patients in whom the minimal distance of the target and optic chiasm or optic nerve was less than 5 mm. Patient characteristics were similar in the two groups, with the exception of tumor volume and previous irradiation. Median tumor volumes were 1.8 cm 3 and 7.7 cm 3 for SRS and SRT, respectively. Three of the SRS and none of the SRT patients had a history of previous external radiation therapy. Both SRS and SRT were performed by the use of dedicated stereotactic 6-MV linear accelerator with a treatment plan designed using a dedicated software. Doses were prescribed to the isodose distribution that covered the identified target. Dose and normalization used for SRS varied from 1000 cGy at 85 % isodose line to 1800 cGy at 80 % isodose line. For SRT patients, total dose of 4500 cGy was normalized at 90 or 95 % isodose line and this was delivered in 25 fractions of 180 cGy daily dose. Results: Local control: There was 1 case of local failure in each of SRS and SRT series (median follow up 42.5 months and 22 month, respectively). CNS adverse effects: There were 3 SRS cases in whom a ring enhancement in the temporal lobe was observed in follow-up MRI. (median follow up 32 months). Of these, one resolved spontaneously, whereas the other 2 lesion persisted and considered to be radiation necrosis. None of them required surgical intervention to date. These were observed in the

  5. Repeated delayed onset cerebellar radiation injuries after linear accelerator-based stereotactic radiosurgery for vestibular schwannoma. Case report

    International Nuclear Information System (INIS)

    Ujifuku, Kenta; Matsuo, Takayuki; Toyoda, Keisuke

    2012-01-01

    A 63-year-old woman presented with right hearing disturbance and vertigo. Magnetic resonance (MR) imaging revealed the presence of right vestibular schwannoma (VS). Stereotactic radiosurgery (SRS) was performed with a tumor marginal dose of 14 Gy using two isocenters. She was followed up clinically and neuroradiologically using three-dimensional spoiled gradient-echo MR imaging. She experienced temporal neurological deterioration due to peritumoral edema in her right cerebellar peduncle and pons for a few months beginning 1.5 years after SRS, when she experienced transient right facial dysesthesia and hearing deterioration. Ten years after SRS, the patient presented with sudden onset of vertigo, gait disturbance, diplopia, dysarthria, and nausea. MR imaging demonstrated a new lesion in the right cerebellar peduncle, which was diagnosed as radiation-induced stroke. The patient was followed up conservatively and her symptoms disappeared within a few months. Multiple delayed onset radiation injuries are possible sequelae of SRS for VS. (author)

  6. Changing practice patterns of Gamma Knife versus linear accelerator-based stereotactic radiosurgery for brain metastases in the US.

    Science.gov (United States)

    Park, Henry S; Wang, Elyn H; Rutter, Charles E; Corso, Christopher D; Chiang, Veronica L; Yu, James B

    2016-04-01

    Single-fraction stereotactic radiosurgery (SRS) is a crucial component in the management of limited brain metastases from non-small cell lung cancer (NSCLC). Intracranial SRS has traditionally been delivered using a frame-based Gamma Knife (GK) platform, but stereotactic modifications to the linear accelerator (LINAC) have made an alternative approach possible. In the absence of definitive prospective trials comparing the efficacy and toxicities of treatment between the 2 techniques, nonclinical factors (such as technology accessibility, costs, and efficiency) may play a larger role in determining which radiosurgery system a facility may choose to install. To the authors' knowledge, this study is the first to investigate national patterns of GK SRS versus LINAC SRS use and to determine which factors may be associated with the adoption of these radiosurgery systems. The National Cancer Data Base was used to identify patients > 18 years old with NSCLC who were treated with single-fraction SRS to the brain between 2003 and 2011. Patients who received "SRS not otherwise specified" or who did not receive a radiotherapy dose within the range of 12-24 Gy were excluded to reduce the potential for misclassification. The chi-square test, t-test, and multivariable logistic regression analysis were used to compare potential demographic, clinicopathologic, and health care system predictors of GK versus LINAC SRS use, when appropriate. This study included 1780 patients, among whom 1371 (77.0%) received GK SRS and 409 (23.0%) underwent LINAC SRS. Over time, the proportion of patients undergoing LINAC SRS steadily increased, from 3.2% in 2003 to 30.8% in 2011 (p < 0.001). LINAC SRS was adopted more rapidly by community versus academic facilities (overall 29.2% vs 17.2%, p < 0.001). On multivariable analysis, 4 independent predictors of increased LINAC SRS use emerged, including year of diagnosis in 2008-2011 versus 2003-2007 (adjusted OR [AOR] 2.04, 95% CI 1.52-2.73, p < 0

  7. Hartree--Slater calculation of the cross section for L-shell ionization of argon by simple heavy charged particles

    International Nuclear Information System (INIS)

    Choi, B.

    1975-01-01

    The cross sections for L-shell and subshell ionization by direct Coulomb excitation of argon by incident heavy charged particles are evaluated. Incident particles are described in the plane-wave Born approximation, and nonrelativistic Hartree-Slater (HS) wave functions are used for the atomic electrons. Form factors, energy distributions, and ionization cross sections are compared with those obtained from screened hydrogenic wave functions. At most incident energies, the HS results for the total ionization cross section are only slightly smaller than those obtained with screened hydrogenic wave functions, but considerable discrepancies are found for form factors and energy distributions near the ionization threshold

  8. ZZ RECOIL/B, Heavy Charged Particle Recoil Spectra Library for Radiation Damage Calculation

    International Nuclear Information System (INIS)

    Gabriel, T.A.; Amburgey, J.D.; Greene, N.M.

    1983-01-01

    1 - Description of problem or function: Format: GAM-II group structure; Number of groups: 104 neutron and Recoil-energy groups; Nuclides: Elements Included in Charged-Particle Recoil Data Base: Al, W, Ti, Pb, V, Mg, Cr, Be, Mn, C, Fe, Au, Co, Si, Ni, B-10, Cu, B-11, Zr, N, Nb, Li-6, Mo, Li-7, Ta (Data for Ta-181,Ta-182), O, Origin: ENDF/B-IV cross-section data. A heavy charged-particle recoil data base (primary knock-on atom (PKA) spectra) and an analysis program have been created to assist experimentalists in studying, evaluating, and correlating radiation-damage effects in different neutron environments. Since experimentally obtained controlled thermo-nuclear-reactor-type neutron spectra are not presently available, the data base can be extremely useful in relating currently obtainable radiation damage to that which is anticipated in future fusion devices. However, the usefulness of the data base is not restricted to just CTR needs. Most of the elements of interest to the radiation-damage community and all neutron reactions of any significance for these elements have been processed, using available ENDF/B-IV cross-section data, and are included in the data base. Calculated data such as primary recoil spectra, displacement rates, and gas-production rates, obtained with the data base, for different radiation environments are presented and compared with previous calculations. Primary neutrons with energies up to 20 MeV have been considered. The elements included in the data base are listed in Table I. All neutron reactions of significance for these elements (i.e., elastic, inelastic, (n,2n), (n,3n), (n,p), (n,sigma), (n,gamma), etc.,) which have cross sections available from ENDF/B-IV have been processed and placed in the data base. Table I - Elements Included in Charged-Particle Recoil Data Base: Al, W, Ti, Pb, V, Mg, Cr, Be, Mn, C, Fe, Au, Co, Si, Ni, 10 B, Cu, 11 B, Zr, N, Nb, 6 Li, Mo, 7 Li, Ta (Data for Ta 181 ,Ta 182 ), O. 2 - Method of solution: The neutron

  9. Verification of the linac isocenter for stereotactic radiosurgery using cine-EPID imaging and arc delivery

    International Nuclear Information System (INIS)

    Rowshanfarzad, Pejman; Sabet, Mahsheed; O' Connor, Daryl J.; Greer, Peter B.

    2011-01-01

    Purpose:Verification of the mechanical isocenter position is required as part of comprehensive quality assurance programs for stereotactic radiosurgery/radiotherapy (SRS/SRT) treatments. Several techniques have been proposed for this purpose but each of them has certain drawbacks. In this paper, a new efficient and more comprehensive method using cine-EPID images has been introduced for automatic verification of the isocenter with sufficient accuracy for stereotactic applications. Methods: Using a circular collimator fixed to the gantry head to define the field, EPID images of a Winston-Lutz phantom were acquired in cine-imaging mode during 360 deg. gantry rotations. A robust matlab code was developed to analyze the data by finding the center of the field and the center of the ball bearing shadow in each image with sub-pixel accuracy. The distance between these two centers was determined for every image. The method was evaluated by comparison to results of a mechanical pointer and also by detection of a manual shift applied to the phantom position. The repeatability and reproducibility of the method were tested and it was also applied to detect couch and collimator wobble during rotation. Results:The accuracy of the algorithm was 0.03 ± 0.02 mm. The repeatability was less than 3 μm and the reproducibility was less than 86 μm. The time elapsed for the analysis of more than 100 cine images of Varian aS1000 and aS500 EPIDs were ∼65 and 20 s, respectively. Processing of images taken in integrated mode took 0.1 s. The output of the analysis software is printable and shows the isocenter shifts as a function of angle in both in-plane and cross-plane directions. It gives warning messages where the shifts exceed the criteria for SRS/SRT and provides useful data for the necessary adjustments in the system including bearing system and/or room lasers. Conclusions: The comprehensive method introduced in this study uses cine-images, is highly accurate, fast, and independent

  10. Verification of the linac isocenter for stereotactic radiosurgery using cine-EPID imaging and arc delivery

    Energy Technology Data Exchange (ETDEWEB)

    Rowshanfarzad, Pejman; Sabet, Mahsheed; O' Connor, Daryl J.; Greer, Peter B. [School of Mathematical and Physical Sciences, University of Newcastle, Newcastle, New South Wales 2308 (Australia); Department of Radiation Oncology, Calvary Mater Newcastle Hospital, Newcastle, New South Wales 2310, Australia and School of Mathematical and Physical Sciences, University of Newcastle, Newcastle, New South Wales 2308 (Australia)

    2011-07-15

    Purpose:Verification of the mechanical isocenter position is required as part of comprehensive quality assurance programs for stereotactic radiosurgery/radiotherapy (SRS/SRT) treatments. Several techniques have been proposed for this purpose but each of them has certain drawbacks. In this paper, a new efficient and more comprehensive method using cine-EPID images has been introduced for automatic verification of the isocenter with sufficient accuracy for stereotactic applications. Methods: Using a circular collimator fixed to the gantry head to define the field, EPID images of a Winston-Lutz phantom were acquired in cine-imaging mode during 360 deg. gantry rotations. A robust matlab code was developed to analyze the data by finding the center of the field and the center of the ball bearing shadow in each image with sub-pixel accuracy. The distance between these two centers was determined for every image. The method was evaluated by comparison to results of a mechanical pointer and also by detection of a manual shift applied to the phantom position. The repeatability and reproducibility of the method were tested and it was also applied to detect couch and collimator wobble during rotation. Results:The accuracy of the algorithm was 0.03 {+-} 0.02 mm. The repeatability was less than 3 {mu}m and the reproducibility was less than 86 {mu}m. The time elapsed for the analysis of more than 100 cine images of Varian aS1000 and aS500 EPIDs were {approx}65 and 20 s, respectively. Processing of images taken in integrated mode took 0.1 s. The output of the analysis software is printable and shows the isocenter shifts as a function of angle in both in-plane and cross-plane directions. It gives warning messages where the shifts exceed the criteria for SRS/SRT and provides useful data for the necessary adjustments in the system including bearing system and/or room lasers. Conclusions: The comprehensive method introduced in this study uses cine-images, is highly accurate, fast, and

  11. Prescription Dose Guideline Based on Physical Criterion for Multiple Metastatic Brain Tumors Treated With Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Sahgal, Arjun; Barani, Igor J.; Novotny, Josef; Zhang Beibei; Petti, Paula; Larson, David A.; Ma Lijun

    2010-01-01

    Purpose: Existing dose guidelines for intracranial stereotactic radiosurgery (SRS) are primarily based on single-target treatment data. This study investigated dose guidelines for multiple targets treated with SRS. Methods and Materials: A physical model was developed to relate the peripheral isodose volume dependence on an increasing number of targets and prescription dose per target. The model was derived from simulated and clinical multiple brain metastatic cases treated with the Leksell Gamma Knife Perfexion at several institutions, where the total number of targets ranged from 2 to 60. The relative increase in peripheral isodose volumes, such as the 12-Gy volume, was studied in the multitarget treatment setting based on Radiation Therapy Oncology Group 90-05 study dose levels. Results: A significant increase in the 12-Gy peripheral isodose volumes was found in comparing multiple target SRS to single-target SRS. This increase strongly correlated (R 2 = 0.92) with the total number of targets but not the total target volumes (R 2 = 0.06). On the basis of the correlated curve, the 12-Gy volume for multiple target treatment was found to increase by approximately 1% per target when a low target dose such as 15 Gy was used, but approximately 4% per target when a high dose such as 20-24 Gy was used. Reduction in the prescription dose was quantified for each prescription level in maintaining the 12-Gy volume. Conclusion: Normal brain dose increases predictably with increasing number of targets for multitarget SRS. A reduction of approximately 1-2 Gy in the prescribed dose is needed compared with single target radiosurgery.

  12. Stereotactic radiosurgery for treatment of brain metastases. A report of the DEGRO Working Group on Stereotactic Radiotherapy

    International Nuclear Information System (INIS)

    Kocher, Martin; Wittig, Andrea; Piroth, Marc Dieter; Treuer, Harald; Ruge, Maximilian; Seegenschmiedt, Heinrich; Grosu, Anca-Ligia; Guckenberger, Matthias

    2014-01-01

    This report from the Working Group on Stereotaktische Radiotherapie of the German Society of Radiation Oncology (Deutsche Gesellschaft fuer Radioonkologie, DEGRO) provides recommendations for the use of stereotactic radiosurgery (SRS) on patients with brain metastases. It considers existing international guidelines and details them where appropriate. The main recommendations are: Patients with solid tumors except germ cell tumors and small-cell lung cancer with a life expectancy of more than 3 months suffering from a single brain metastasis of less than 3 cm in diameter should be considered for SRS. Especially when metastases are not amenable to surgery, are located in the brain stem, and have no mass effect, SRS should be offered to the patient. For multiple (two to four) metastases - all less than 2.5 cm in diameter - in patients with a life expectancy of more than 3 months, SRS should be used rather than whole-brain radiotherapy (WBRT). Adjuvant WBRT after SRS for both single and multiple (two to four) metastases increases local control and reduces the frequency of distant brain metastases, but does not prolong survival when compared with SRS and salvage treatment. As WBRT carries the risk of inducing neurocognitive damage, it seems reasonable to withhold WBRT for as long as possible. A single (marginal) dose of 20 Gy is a reasonable choice that balances the effect on the treated lesion (local control, partial remission) against the risk of late side effects (radionecrosis). Higher doses (22-25 Gy) may be used for smaller ( [de

  13. Gamma Knife Radiosurgery for Patients With Nonfunctioning Pituitary Adenomas: Results From a 15-Year Experience

    International Nuclear Information System (INIS)

    Pollock, Bruce E.; Cochran, Joseph; Natt, Neena; Brown, Paul D.; Erickson, Dana; Link, Michael J.; Garces, Yolanda I.; Foote, Robert L.; Stafford, Scott L.; Schomberg, Paula J.

    2008-01-01

    Purpose: To evaluate the efficacy and complications of stereotactic radiosurgery for patients with nonfunctioning pituitary adenomas (NFA). Methods and Materials: This was a retrospective review of 62 patients with NFA undergoing radiosurgery between 1992 and 2004, of whom 59 (95%) underwent prior tumor resection. The median treatment volume was 4.0 cm 3 (range, 0.8-12.9). The median treatment dose to the tumor margin was 16 Gy (range, 11-20). The median maximum point dose to the optic apparatus was 9.5 Gy (range, 5.0-12.6). The median follow-up period after radiosurgery was 64 months (range, 23-161). Results: Tumor size decreased for 37 patients (60%) and remained unchanged for 23 patients (37%). Two patients (3%) had tumor growth outside the prescribed treatment volume and required additional treatment (fractionated radiation therapy, n = 1; repeat radiosurgery, n 1). Tumor growth control was 95% at 3 and 7 years after radiosurgery. Eleven (27%) of 41 patients with normal (n = 30) or partial (n = 11) anterior pituitary function before radiosurgery developed new deficits at a median of 24 months after radiosurgery. The risk of developing new anterior pituitary deficits at 5 years was 32%. The 5-year risk of developing new anterior pituitary deficits was 18% for patients with a tumor volume of ≤4.0 cm 3 compared with 58% for patients with a tumor volume >4.0 cm 3 (risk ratio 4.5; 95% confidence interval = 1.3-14.9, p = 0.02). No patient had a decline in visual function. Conclusions: Stereotactic radiosurgery is effective in the management of patients with residual or recurrent NFA, although longer follow-up is needed to evaluate long-term outcomes. The primary complication is hypopituitarism, and the risk of developing new anterior pituitary deficits correlates with the size of the irradiated tumor

  14. Compensating for Quasi-periodic Motion in Robotic Radiosurgery

    CERN Document Server

    Ernst, Floris

    2012-01-01

    Compensating for Quasi-periodic Motion in Robotic Radiosurgery outlines the techniques needed to accurately track and compensate for respiratory and pulsatory motion during robotic radiosurgery. The algorithms presented within the book aid in the treatment of tumors that move during respiration. In Chapters 1 and 2,  the book introduces the concept of stereotactic body radiation therapy, motion compensation strategies and the clinical state-of-the-art. In Chapters 3 through 5, the author describes and evaluates new methods for motion prediction, for correlating external motion to internal organ motion, and for the evaluation of these algorithms’ output based on an unprecedented amount of real clinical data. Finally, Chapter 6 provides a brief introduction into currently investigated, open questions and further fields of research. Compensating for Quasi-periodic Motion in Robotic Radiosurgery targets researchers working in the related fields of surgical oncology, artificial intelligence, robotics and more. ...

  15. Radiosurgery for brain metastases: a score index for predicting prognosis

    International Nuclear Information System (INIS)

    Weltman, Eduardo; Salvajoli, Joao Victor; Brandt, Reynaldo Andre; Morais Hanriot, Rodrigo de; Prisco, Flavio Eduardo; Cruz, Jose Carlos; Oliveira Borges, Sandra Regina de; Wajsbrot, Dalia Ballas

    2000-01-01

    Purpose: To analyze a prognostic score index for patients with brain metastases submitted to stereotactic radiosurgery (the Score Index for Radiosurgery in Brain Metastases [SIR]). Methods and Materials: Actuarial survival of 65 brain metastases patients treated with radiosurgery between July 1993 and December 1997 was retrospectively analyzed. Prognostic factors included age, Karnofsky performance status (KPS), extracranial disease status, number of brain lesions, largest brain lesion volume, lesions site, and receiving or not whole brain irradiation. The SIR was obtained through summation of the previously noted first five prognostic factors. Kaplan-Meier actuarial survival curves for all prognostic factors, SIR, and recursive partitioning analysis (RPA) (RTOG prognostic score) were calculated. Survival curves of subsets were compared by log-rank test. Application of the Cox model was utilized to identify any correlation between prognostic factors, prognostic scores, and survival. Results: Median overall survival from radiosurgery was 6.8 months. Utilizing univariate analysis, extracranial disease status, KPS, number of brain lesions, largest brain lesion volume, RPA, and SIR were significantly correlated with prognosis. Median survival for the RPA classes 1, 2, and 3 was 20.19 months, 7.75 months, and 3.38 months respectively (p = 0.0131). Median survival for patients, grouped under SIR from 1 to 3, 4 to 7, and 8 to 10, was 2.91 months, 7.00 months, and 31.38 months respectively (p = 0.0001). Using the Cox model, extracranial disease status and KPS demonstrated significant correlation with prognosis (p 0.0001 and 0.0004 respectively). Multivariate analysis also demonstrated significance for SIR and RPA when tested individually (p = 0.0001 and 0.0040 respectively). Applying the Cox Model to both SIR and RPA, only SIR reached independent significance (p = 0.0004). Conclusions: Systemic disease status, KPS, SIR, and RPA are reliable prognostic factors for patients

  16. Characteristics of Philips SL-20 linear accelerator used for stereotactic radiosurgery/radiotherapy

    International Nuclear Information System (INIS)

    D'Souza, Harold; Ganesh, T.; Joshi, R.C.; Julka, P.K.; Rath, G.K.; Chander, Subhash; Pant, G.S.

    2002-01-01

    Commissioning of a stereotactic radiosurgery/stereotactic radiotherapy (SRS/SRT) facility on a modified linear accelerator requires validation of mechanical parameters and establishment of parameters, such as tissue maximum ratio (TMR), relative output factors (OF), and off axis ratios (OAR). The mechanical and beam characteristics of Philips SL-20 linear accelerator modified for SRS/SRT were evaluated and presented. The SRS/SRT procedure carried on Philips SL-20 linear accelerator with Brown-Robert-Wells (BRW) and relocatable Gill-Thomas-Cosman (GTC) head frames along with the Radionics planning system was evaluated. The tertiary collimator consists of the actual treatment cones and their sizes vary from 12.5 mm to 40 mm diameter. The alignment of the auxillary collimator axis with mechanical axes and stability of the isocenter of Philips SL-20 machine was evaluated using Iso-Align device and mechanical isocenter standard (MIS). All the mechanical errors of the linear accelerator were within 1 mm, except the stability of the isocenter while rotating the couch. Alignment of auxiliary collimator axis with the central axis, gantry and couch axes were achieved. The TMR, OF and OAR for 6 MV x-rays from Philips SL-20 linear accelerator for different cone sizes were deduced using a Multidata water phantom with 0.015 cc ion chamber. The difference between 50% width of profiles in two major axes (x and y) were within ± 0.4 mm. The cone dimensions were accurate up to 0.7 mm. The penumbra width for different cones varies from 3.1 mm to 3.5 mm. Dose linearity of the monitoring system was ≤ 1% above 5 MU. The mechanical and beam characteristics including dose linearity of the SL-20 machine are presented. The beam characteristics of this machine are comparable with the other modified linear accelerators for SRS/SRT. The shift of isocenter during rotation of couch can be nullified by fine adjusting laser target localizing frame to the laser position using micrometer screws

  17. Characteristics of a dedicated linear accelerator-based stereotactic radiosurgery-radiotherapy unit

    International Nuclear Information System (INIS)

    Das, Indra J.; Downes, M. Beverly; Corn, Benjamin W.; Curran, Walter J.; Werner-Wasik, M.; Andrews, David W.

    1996-01-01

    A stereotactic radiosurgery and radiotherapy (SRS/SRT) system on a dedicated Varian Clinac-600SR linear accelerator with Brown-Roberts-Wells and Gill-Thomas-Cosman relocatable frames along with the Radionics (RSA) planning system is evaluated. The Clinac-600SR has a single 6-MV beam with the same beam characteristics as that of the mother unit, the Clinac-600C. The primary collimator is a fixed cone projecting to a 10-cm diameter at isocenter. The secondary collimator is a heavily shielded cylindrical collimator attached to the face plate of the primary collimator. The tertiary collimation consists of the actual treatment cones. The cone sizes vary from 12.5 to 40.0 mm diameter. The mechanical stability of the entire system was verified. The variations in isocenter position with table, gantry, and collimator rotation were found to be <0.5 mm with a compounded accuracy of ≤ 1.0 mm. The radiation leakage under the cones was < 1% measured at a depth of 5 cm in a phantom. The beam profiles of all cones in the x and y directions were within ±0.5 mm and match with the physical size of the cone. The dosimetric data such as tissue maximum ratio, off-axis ratio, and cone factor were taken using film, diamond detector, and ion chambers. The mechanical and dosimetric characteristics including dose linearity of this unit are presented and found to be suitable for SRS/SRT. The difficulty in absolute dose measurement for small cone is discussed

  18. Slow, target associated particles produced in ultrarelativistic heavy-ion interactions

    Energy Technology Data Exchange (ETDEWEB)

    Adamovich, M I; Aggarwal, M M; Alexandrov, Y A; Andreeva, N P; Anson, Z V; Arora, R; Avetyan, F A; Badyal, S K; Basova, E; Bhalla, K B; Bhasin, A; Bhatia, V S; Bogdanov, V G; Bubnov, V I; Burnett, T H; Cai, X; Chasnikov, I Y; Chernova, L P; Chernyavsky, M M; Dressel, B; Eligbaeva, G Z; Eremenko, L E; Friedlander, E M; Gaitinov, A S; Ganssauge, E R; Garpman, S; Gerassimov, S G; Grote, J; Gulamov, K G; Gupta, S K; Gupta, V; Heckman, H H; Huang, H; Jakobsson, B; Judek, B; Kachroo, S; Kadyrov, F G; Kalyachkina, G S; Kanygina, E K; Karabova, M; Kaul, G L; Kaur, M; Kharlamov, S P; Koss, Y; Krasnov,; Kumar,; Lal, P; Larionova,; Lepetan,; Lindstrom,; Liu,; Lokanathan, S; Lord, J; Lukicheva, N S; Luo, S B; Mangotra, L K; Marutyan,; Maslennikova, N V; Mittra, I S; Mookerjee, S; Mueller, C; Nasrulaeva, H; Nasyrov, S H; Navotny, V S; Orlova, G I; Otterlund, I; Palsania, H S; Peresadko, N G; Petrov, N V; Plyushchev, V A; Qian, W Y; Raniwala,; EMU01 Collaboration

    1991-06-20

    The slow, target associated particles produced in ultrarelativistic heavy-ion interactions are a quantitative probe of the cascading processes in the spectator parts of the target nucleus. These processes are directly influenced by the proper timescale for the formation of hadronic matter. In this letter we show experimental data on singly and multiply charged particles, with velocities smaller than 0.7c, produced in ultrarelativistic heavy-ion interactions in nuclear emulsion. (orig.).

  19. CyberKnife radiosurgery: Precision without incision

    Directory of Open Access Journals (Sweden)

    Enja Siva Prasad Reddy

    2015-01-01

    Full Text Available CyberKnife stereotactic radiosurgery system is an innovative, effective, frameless, non-invasive substitute for conventional surgical treatment of cancer. It works on the principle of stereotaxy. It is used for the treatment of both cancerous and non-cancerous tumors, intracranial lesions, tumors of lung, spine, prostate, and kidney, recurrent cases of oral squamous cell carcinoma, arteriovenous malformation, and trigeminal neuralgia. It has an advantage over other systems like Gamma knife radiosurgery and linear accelerator (LINAC-based systems, as it is frameless, has submillimeter accuracy, does not affect the normal cells adjacent to the lesion, and tracks the lesion in synchronization with the patient′s respiratory rate. The future of CyberKnife encompasses possibilities such as incremental improvements in accuracy and better shaping of the field of radiation and would certainly allow extension of radiosurgery as an effective substitute for chemotherapy. This paper aims to review and highlight the immense potential that CyberKnife holds in the field of dentistry in treating disorders of the head and neck region, thereby ensuring enhanced longevity for the patients.

  20. Charged Hadron Multiplicity Distribution at Relativistic Heavy-Ion Colliders

    Directory of Open Access Journals (Sweden)

    Ashwini Kumar

    2013-01-01

    Full Text Available The present paper reviews facts and problems concerning charge hadron production in high energy collisions. Main emphasis is laid on the qualitative and quantitative description of general characteristics and properties observed for charged hadrons produced in such high energy collisions. Various features of available experimental data, for example, the variations of charged hadron multiplicity and pseudorapidity density with the mass number of colliding nuclei, center-of-mass energies, and the collision centrality obtained from heavy-ion collider experiments, are interpreted in the context of various theoretical concepts and their implications. Finally, several important scaling features observed in the measurements mainly at RHIC and LHC experiments are highlighted in the view of these models to draw some insight regarding the particle production mechanism in heavy-ion collisions.

  1. Neutron irradiation of bacteria in the presence and absence of secondary charged-particle equilibrium

    International Nuclear Information System (INIS)

    Lunec, J.; Cramp, W.A.; Hornsey, S.

    1980-01-01

    The survival rate of Shigella flexneri has been measured for irradiation with 7-MeV neutrons in the presence and absence of secondary charged-particle equilibrium. The data were analyzed to assess the separate response of the cells to the knock-on proton and α-particle plus heavy-recoil components. A detailed consideration of the frequency of α-particle and heavy-recoil traversals of the cell has been made to explain our results, and in addition we have applied this approach to analyze the earlier results obtained with mammalian cells. We conclude that of the secondary charged-particles produced by the Hammersmith neutron beam, the highest LET particles, the heavy-recoil nuclei, contribute a minor proportion of damage to bacteria but form a major contribution of damage in mammalian cells. The reduction in oxygen enhancement ratio (OER) with neutrons compared with low LET radiation for mammalian cells is due almost entirely to the influence of the heavy recoils and the contribution of the α-particle and knock-on protons to the reduction of the OER is relatively minor. For Shigella flexneri the α particles and heavy recoils make approximately equal contributions to the reduction in OER

  2. Linac-based radiosurgery of cerebral melanoma metastases. Analysis of 122 metastases treated in 64 patients

    International Nuclear Information System (INIS)

    Herfarth, K.K.; Pirzkall, A.; Izwekowa, O.; Wannenmacher, M.; Thilmann, C.; Debus, J.; Delorme, S.; Hofmann, U.; Schadendorf, D.; Zierhut, D.

    2003-01-01

    Purpose: Stereotactic radiosurgery is an alternative option to neurosurgical excision in the management of patients with brain metastases. We retrospectively analyzed patients with brain metastases of malignant melanoma who were treated at our institution for outcome and prognostic factors. Patients and Methods: 64 patients with 122 cerebral metastases were treated with stereotactic radiosurgery between 1986 and 2000. Twelve patients (19%) showed neurologic symptoms at the time of treatment, and 46 patients (72%) had extracerebral tumor manifestation at that time. The median dose to the 80% isodose line, prescribed to encompass the tumor margin, was 20 Gy (range, 15-22 Gy). Results: Neurologic symptoms improved in five of twelve symptomatic patients. 41 patients remained asymptomatic or unchanged in their neurologic symptoms. Only five patients (8%) temporarily worsened neurologically after therapy despite no signs of tumor progression. With a mean follow-up time of 9.4 months, actuarial local control was 81% after 1 year. There was a statistically significant dose and size dependency of local tumor control. Median actuarial survival after treatment was 10.6 months. Patients without extracerebral tumor manifestation showed a superior survival (p = 0.04). Conclusions: Despite high local tumor control rates, the prognosis of patients with cerebral metastases of malignant melanoma remains poor. Stereotactic radiosurgery has the potential of stabilizing or improving neurologic symptoms in these patients in a palliative setting. (orig.)

  3. Simulation of distributed parameter system consisting of charged and neutral particles

    International Nuclear Information System (INIS)

    Grover, P.S.; Sinha, K.V.

    1986-01-01

    The time-dependent behavior of positively charged light particles have been simulated in an assembly of heavy gas atoms. The system is formulated in terms of partial differential equation. The stability and convergence of the numerical algorithm has been examined. Using this formulation effects of external electric field and temperature have been investigated on the lifetime and distribution function characteristics of charged particles

  4. Improved target volume definition in radiosurgery of arteriovenous malformations by stereotactic correlation of MRA, MRI, blood bolus tagging, and functional MRI

    International Nuclear Information System (INIS)

    Schad, L.R.; Bock, M.; Baudendistel, K.; Essig, M.; Debus, J.; Knopp, M.V.; Engenhart, R.; Lorenz, W.J.

    1996-01-01

    The authors report the sterotactic correlation of different MRI-techniques [MR angiography (MRA), MRI, blood bolus tagging (STAR), and functional MRI] in 10 patients with cerebral arteriovenous malformations (AVM) and its application in precision radiotherapy planning. The patient's head was fixed in a stereotactic localization system. By phantom measurements different materials (steel, aluminium, titanium, plastic, wood, ceramics) used for the stereotactic system were tested for mechanical stability and geometrical MR image distortion. All metallic stereotactic rings led to a more or less dramatic geometrical distortion and signal cancellation in the MR images. The best properties - nearly no distortion and high mechanical stability - are provided by a ceramic ring. If necessary, the remaining geometrical MR image distortion can be 'corrected' by calculations based on modeling the distortion as a fourth-order 2D-polynomial. Using this method multimodality matching can be performed automatically as long as all images are acquired in the same examination and the patient is sufficiently immobilized. Precise definition of the target volume could be performed by the radiotherapist either directly in MR images or in calculated projection MR angiograms. As a result, information about the hemodynamics of the AVM was provided by a 3D-phase-contrast flow measurement and a dynamic MRA with the STAR technique leading to an improved definition of the size of the nidus, and the pattern of the venous drainage. In addition, functional MRI was performed in patients with lesions close to the primary motor cortex area leading to an improved definition of structures at risk for high-dose application in radiosurgery. (orig./MG)

  5. Gamma Knife Stereotactic Radiosurgery as Salvage Therapy After Failure of Whole-Brain Radiotherapy in Patients With Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Harris, Sunit; Chan, Michael D.; Lovato, James F.; Ellis, Thomas L.; Tatter, Stephen B.; Bourland, J. Daniel; Munley, Michael T.; Guzman, Allan F. de; Shaw, Edward G.; Urbanic, James J.; McMullen, Kevin P.

    2012-01-01

    Purpose: Radiosurgery has been successfully used in selected cases to avoid repeat whole-brain irradiation (WBI) in patients with multiple brain metastases of most solid tumor histological findings. Few data are available for the use of radiosurgery for small-cell lung cancer (SCLC). Methods and Materials: Between November 1999 and June 2009, 51 patients with SCLC and previous WBI and new brain metastases were treated with GammaKnife stereotactic radiosurgery (GKSRS). A median dose of 18 Gy (range, 10–24 Gy) was prescribed to the margin of each metastasis. Patients were followed with serial imaging. Patient electronic records were reviewed to determine disease-related factors and clinical outcomes after GKSRS. Local and distant brain failure rates, overall survival, and likelihood of neurologic death were determined based on imaging results. The Kaplan-Meier method was used to determine survival and local and distant brain control. Cox proportional hazard regression was performed to determine strength of association between disease-related factors and survival. Results: Median survival time for the entire cohort was 5.9 months. Local control rates at 1 and 2 years were 57% and 34%, respectively. Distant brain failure rates at 1 and 2 years were 58% and 75%, respectively. Fifty-three percent of patients ultimately died of neurologic death. On multivariate analysis, patients with stable (hazard ratio [HR] = 2.89) or progressive (HR = 6.98) extracranial disease (ECD) had worse overall survival than patients without evidence of ECD (p = 0.00002). Concurrent chemotherapy improved local control (HR = 89; p = 0.006). Conclusions: GKSRS represents a feasible salvage option in patients with SCLC and brain metastases for whom previous WBI has failed. The status of patients’ ECD is a dominant factor predictive of overall survival. Local control may be inferior to that seen with other cancer histological results, although the use of concurrent chemotherapy may help to

  6. Gamma Knife Stereotactic Radiosurgery as Salvage Therapy After Failure of Whole-Brain Radiotherapy in Patients With Small-Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Sunit [Department of Radiation Oncology, Wake Forest University, Winston-Salem, North Carolina (United States); Chan, Michael D., E-mail: mchan@wfubmc.edu [Department of Radiation Oncology, Wake Forest University, Winston-Salem, North Carolina (United States); Lovato, James F. [Division of Public Health Sciences, Wake Forest University, Winston-Salem, North Carolina (United States); Ellis, Thomas L.; Tatter, Stephen B. [Department of Neurosurgery, Wake Forest University, Winston-Salem, North Carolina (United States); Bourland, J. Daniel; Munley, Michael T.; Guzman, Allan F. de; Shaw, Edward G.; Urbanic, James J.; McMullen, Kevin P. [Department of Radiation Oncology, Wake Forest University, Winston-Salem, North Carolina (United States)

    2012-05-01

    Purpose: Radiosurgery has been successfully used in selected cases to avoid repeat whole-brain irradiation (WBI) in patients with multiple brain metastases of most solid tumor histological findings. Few data are available for the use of radiosurgery for small-cell lung cancer (SCLC). Methods and Materials: Between November 1999 and June 2009, 51 patients with SCLC and previous WBI and new brain metastases were treated with GammaKnife stereotactic radiosurgery (GKSRS). A median dose of 18 Gy (range, 10-24 Gy) was prescribed to the margin of each metastasis. Patients were followed with serial imaging. Patient electronic records were reviewed to determine disease-related factors and clinical outcomes after GKSRS. Local and distant brain failure rates, overall survival, and likelihood of neurologic death were determined based on imaging results. The Kaplan-Meier method was used to determine survival and local and distant brain control. Cox proportional hazard regression was performed to determine strength of association between disease-related factors and survival. Results: Median survival time for the entire cohort was 5.9 months. Local control rates at 1 and 2 years were 57% and 34%, respectively. Distant brain failure rates at 1 and 2 years were 58% and 75%, respectively. Fifty-three percent of patients ultimately died of neurologic death. On multivariate analysis, patients with stable (hazard ratio [HR] = 2.89) or progressive (HR = 6.98) extracranial disease (ECD) had worse overall survival than patients without evidence of ECD (p = 0.00002). Concurrent chemotherapy improved local control (HR = 89; p = 0.006). Conclusions: GKSRS represents a feasible salvage option in patients with SCLC and brain metastases for whom previous WBI has failed. The status of patients' ECD is a dominant factor predictive of overall survival. Local control may be inferior to that seen with other cancer histological results, although the use of concurrent chemotherapy may help to

  7. Effect of the embolization material in the dose calculation for stereotactic radiosurgery of arteriovenous malformations

    International Nuclear Information System (INIS)

    Galván de la Cruz, Olga Olinca; Lárraga-Gutiérrez, José Manuel; Moreno-Jiménez, Sergio; García-Garduño, Olivia Amanda; Celis, Miguel Angel

    2013-01-01

    It is reported in the literature that the material used in an embolization of an arteriovenous malformation (AVM) can attenuate the radiation beams used in stereotactic radiosurgery (SRS) up to 10% to 15%. The purpose of this work is to assess the dosimetric impact of this attenuating material in the SRS treatment of embolized AVMs, using Monte Carlo simulations assuming clinical conditions. A commercial Monte Carlo dose calculation engine was used to recalculate the dose distribution of 20 AVMs previously planned with a pencil beam dose calculation algorithm. Dose distributions were compared using the following metrics: average, minimal and maximum dose of AVM, and 2D gamma index. The effect in the obliteration rate was investigated using radiobiological models. It was found that the dosimetric impact of the embolization material is less than 1.0 Gy in the prescription dose to the AVM for the 20 cases studied. The impact in the obliteration rate is less than 4.0%. There is reported evidence in the literature that embolized AVMs treated with SRS have low obliteration rates. This work shows that there are dosimetric implications that should be considered in the final treatment decisions for embolized AVMs

  8. Effect of the embolization material in the dose calculation for stereotactic radiosurgery of arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Galván de la Cruz, Olga Olinca [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico); Lárraga-Gutiérrez, José Manuel, E-mail: jlarraga@innn.edu.mx [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico); Laboratorio de Física Médica, Instituto Nacional de Neurología y Neurocirugía (Mexico); Moreno-Jiménez, Sergio [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico); García-Garduño, Olivia Amanda [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico); Laboratorio de Física Médica, Instituto Nacional de Neurología y Neurocirugía (Mexico); Celis, Miguel Angel [Unidad de Radioneurocirugía, Instituto Nacional de Neurología y Neurocirugía (Mexico)

    2013-07-01

    It is reported in the literature that the material used in an embolization of an arteriovenous malformation (AVM) can attenuate the radiation beams used in stereotactic radiosurgery (SRS) up to 10% to 15%. The purpose of this work is to assess the dosimetric impact of this attenuating material in the SRS treatment of embolized AVMs, using Monte Carlo simulations assuming clinical conditions. A commercial Monte Carlo dose calculation engine was used to recalculate the dose distribution of 20 AVMs previously planned with a pencil beam dose calculation algorithm. Dose distributions were compared using the following metrics: average, minimal and maximum dose of AVM, and 2D gamma index. The effect in the obliteration rate was investigated using radiobiological models. It was found that the dosimetric impact of the embolization material is less than 1.0 Gy in the prescription dose to the AVM for the 20 cases studied. The impact in the obliteration rate is less than 4.0%. There is reported evidence in the literature that embolized AVMs treated with SRS have low obliteration rates. This work shows that there are dosimetric implications that should be considered in the final treatment decisions for embolized AVMs.

  9. SU-F-T-566: Absolute Film Dosimetry for Stereotactic Radiosurgery and Stereotactic Body Radiotherapy Quality Assurance Using Gafchromic EBT3 Films

    Energy Technology Data Exchange (ETDEWEB)

    Wen, N; Lu, S; Qin, Y; Huang, Y; Zhao, B; Liu, C; Chetty, I [Henry Ford Health System, Detroit, MI (United States)

    2016-06-15

    Purpose: To evaluate the dosimetric uncertainty associated with Gafchromic (EBT3) films and establish an absolute dosimetry protocol for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT). Methods: EBT3 films were irradiated at each of seven different dose levels between 1 and 15 Gy with open fields, and standard deviations of dose maps were calculated at each color channel for evaluation. A scanner non-uniform response correction map was built by registering and comparing film doses to the reference diode array-based dose map delivered with the same doses. To determine the temporal dependence of EBT3 films, the average correction factors of different dose levels as a function of time were evaluated up to four days after irradiation. An integrated film dosimetry protocol was developed for dose calibration, calibration curve fitting, dose mapping, and profile/gamma analysis. Patient specific quality assurance (PSQA) was performed for 93 SRS/SBRT treatment plans. Results: The scanner response varied within 1% for the field sizes less than 5 × 5 cm{sup 2}, and up to 5% for the field sizes of 10 × 10 cm{sup 2}. The scanner correction method was able to remove visually evident, irregular detector responses found for larger field sizes. The dose response of the film changed rapidly (∼10%) in the first two hours and plateaued afterwards, ∼3% change between 2 and 24 hours. The mean uncertainties (mean of the standard deviations) were <0.5% over the dose range 1∼15Gy for all color channels for the OD response curves. The percentage of points passing the 3%/1mm gamma criteria based on absolute dose analysis, averaged over all tests, was 95.0 ± 4.2. Conclusion: We have developed an absolute film dose dosimetry protocol using EBT3 films. The overall uncertainty has been established to be approximately 1% for SRS and SBRT PSQA. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.

  10. Mass and Charge Measurements on Heavy Ions

    Science.gov (United States)

    Sugai, Toshiki

    2017-01-01

    The relationship between mass and charge has been a crucial topic in mass spectrometry (MS) because the mass itself is typically evaluated based on the m/z ratio. Despite the fact that this measurement is indirect, a precise mass can be obtained from the m/z value with a high m/z resolution up to 105 for samples in the low mass and low charge region under 10,000 Da and 20 e, respectively. However, the target of MS has recently been expanded to the very heavy region of Mega or Giga Da, which includes large particles and biocomplexes, with very large and widely distributed charge from kilo to Mega range. In this region, it is necessary to evaluate charge and mass simultaneously. Recent studies for simultaneous mass and charge observation and related phenomena are discussed in this review. PMID:29302406

  11. Computer-based radiological longitudinal evaluation of meningiomas following stereotactic radiosurgery.

    Science.gov (United States)

    Shimol, Eli Ben; Joskowicz, Leo; Eliahou, Ruth; Shoshan, Yigal

    2018-02-01

    Stereotactic radiosurgery (SRS) is a common treatment for intracranial meningiomas. SRS is planned on a pre-therapy gadolinium-enhanced T1-weighted MRI scan (Gd-T1w MRI) in which the meningioma contours have been delineated. Post-SRS therapy serial Gd-T1w MRI scans are then acquired for longitudinal treatment evaluation. Accurate tumor volume change quantification is required for treatment efficacy evaluation and for treatment continuation. We present a new algorithm for the automatic segmentation and volumetric assessment of meningioma in post-therapy Gd-T1w MRI scans. The inputs are the pre- and post-therapy Gd-T1w MRI scans and the meningioma delineation in the pre-therapy scan. The output is the meningioma delineations and volumes in the post-therapy scan. The algorithm uses the pre-therapy scan and its meningioma delineation to initialize an extended Chan-Vese active contour method and as a strong patient-specific intensity and shape prior for the post-therapy scan meningioma segmentation. The algorithm is automatic, obviates the need for independent tumor localization and segmentation initialization, and incorporates the same tumor delineation criteria in both the pre- and post-therapy scans. Our experimental results on retrospective pre- and post-therapy scans with a total of 32 meningiomas with volume ranges 0.4-26.5 cm[Formula: see text] yield a Dice coefficient of [Formula: see text]% with respect to ground-truth delineations in post-therapy scans created by two clinicians. These results indicate a high correspondence to the ground-truth delineations. Our algorithm yields more reliable and accurate tumor volume change measurements than other stand-alone segmentation methods. It may be a useful tool for quantitative meningioma prognosis evaluation after SRS.

  12. Frameless Angiogram-Based Stereotactic Radiosurgery for Treatment of Arteriovenous Malformations

    International Nuclear Information System (INIS)

    Lu Xingqi; Mahadevan, Anand; Mathiowitz, George; Lin, Pei-Jan P.; Thomas, Ajith; Kasper, Ekkehard M.; Floyd, Scott R.; Holupka, Edward; La Rosa, Salvatore; Wang, Frank; Stevenson, Mary Ann

    2012-01-01

    Purpose: Stereotactic radiosurgery (SRS) is an effective alternative to microsurgical resection or embolization for definitive treatment of arteriovenous malformations (AVMs). Digital subtraction angiography (DSA) is the gold standard for pretreatment diagnosis and characterization of vascular anatomy, but requires rigid frame (skull) immobilization when used in combination with SRS. With the advent of advanced proton and image-guided photon delivery systems, SRS treatment is increasingly migrating to frameless platforms, which are incompatible with frame-based DSA. Without DSA as the primary image, target definition may be less than optimal, in some cases precluding the ability to treat with a frameless system. This article reports a novel solution. Methods and Materials: Fiducial markers are implanted into the patient’s skull before angiography. Angiography is performed according to the standard clinical protocol, but, in contrast to the previous practice, without the rigid frame. Separate images of a specially designed localizer box are subsequently obtained. A target volume projected on DSA can be transferred to the localizer system in three dimensions, and in turn be transferred to multiple CT slices using the implanted fiducials. Combined with other imaging modalities, this “virtual frame” approach yields a highly precise treatment plan that can be delivered by frameless SRS technologies. Results: Phantom measurements for point and volume targets have been performed. The overall uncertainty of placing a point target to CT is 0.4 mm. For volume targets, deviation of the transformed contour from the target CT image is within 0.6 mm. The algorithm and software are robust. The method has been applied clinically, with reliable results. Conclusions: A novel and reproducible method for frameless SRS of AVMs has been developed that enables the use of DSA without the requirement for rigid immobilization. Multiple pairs of DSA can be used for better conformality

  13. Combining stereotactic radiosurgery and systemic therapy for brain metastases: a potential role for temozolomide

    Energy Technology Data Exchange (ETDEWEB)

    Hardee, Matthew E. [Department of Radiation Oncology, New York University Langone Medical Center, New York, NY (United States); Formenti, Silvia C., E-mail: silvia.formenti@nyumc.org [Department of Radiation Oncology, New York University Langone Medical Center, New York, NY (United States); Department of Medical Oncology, New York University Langone Medical Center, New York, NY (United States)

    2012-08-09

    Brain metastases are unfortunately very common in the natural history of many solid tumors and remain a life-threatening condition, associated with a dismal prognosis, despite many clinical trials aimed at improving outcomes. Radiation therapy options for brain metastases include whole brain radiotherapy (WBRT) and stereotactic radiosurgery (SRS). SRS avoids the potential toxicities of WBRT and is associated with excellent local control (LC) rates. However, distant intracranial failure following SRS remains a problem, suggesting that untreated intracranial micrometastatic disease is responsible for failure of treatment. The oral alkylating agent temozolomide (TMZ), which has demonstrated efficacy in primary malignant central nervous system tumors such as glioblastoma, has been used in early phase trials in the treatment of established brain metastases. Although results of these studies in established, macroscopic metastatic disease have been modest at best, there is clinical and preclinical data to suggest that TMZ is more efficacious at treating and controlling clinically undetectable intracranial micrometastatic disease. We review the available data for the primary management of brain metastases with SRS, as well as the use of TMZ in treating established brain metastases and undetectable micrometastatic disease, and suggest the role for a clinical trial with the aims of treating macroscopically visible brain metastases with SRS combined with TMZ to address microscopic, undetectable disease.

  14. KNO type scaling of secondary charged particles produced in 4.5 a GeV 12C-nucleus collisions

    International Nuclear Information System (INIS)

    Khushnood, H.; Singh, Prithipal; Shukla, Praveen Prakash; Saleem Khan, M.

    2011-01-01

    Study of the secondary charged particles produced in heavy ion collisions is attracting a great deal of attention during the recent years. It is reported that the multiplicity distribution of secondary charged particles produced in high energy hadron-hadron and hadron-nucleus collisions Obey Koba, Nielson and Olesen (KNO) scaling. However, no attention has been paid to study the nature of the multiplicity distribution of secondary charged particles produced in relativistic heavy ions reactions. Thus, an attempt has been made to study the multiplicity distribution of secondary charged particles produced in 4.5 A GeV 12 C-nucleus interactions

  15. Factors Predictive of Symptomatic Radiation Injury After Linear Accelerator-Based Stereotactic Radiosurgery for Intracerebral Arteriovenous Malformations

    International Nuclear Information System (INIS)

    Herbert, Christopher; Moiseenko, Vitali; McKenzie, Michael; Redekop, Gary; Hsu, Fred; Gete, Ermias; Gill, Brad; Lee, Richard; Luchka, Kurt; Haw, Charles; Lee, Andrew; Toyota, Brian; Martin, Montgomery

    2012-01-01

    Purpose: To investigate predictive factors in the development of symptomatic radiation injury after treatment with linear accelerator–based stereotactic radiosurgery for intracerebral arteriovenous malformations and relate the findings to the conclusions drawn by Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC). Methods and Materials: Archived plans for 73 patients who were treated at the British Columbia Cancer Agency were studied. Actuarial estimates of freedom from radiation injury were calculated using the Kaplan-Meier method. Univariate and multivariate Cox proportional hazards models were used for analysis of incidence of radiation injury. Log–rank test was used to search for dosimetric parameters associated with freedom from radiation injury. Results: Symptomatic radiation injury was exhibited by 14 of 73 patients (19.2%). Actuarial rate of symptomatic radiation injury was 23.0% at 4 years. Most patients (78.5%) had mild to moderate deficits according to Common Terminology Criteria for Adverse Events, version 4.0. On univariate analysis, lesion volume and diameter, dose to isocenter, and a V x for doses ≥8 Gy showed statistical significance. Only lesion diameter showed statistical significance (p 5 cm 3 and diameters >30 mm were significantly associated with the risk of radiation injury (p 12 also showed strong association with the incidence of radiation injury. Actuarial incidence of radiation injury was 16.8% if V 12 was 3 and 53.2% if >28 cm 3 (log–rank test, p = 0.001). Conclusions: This study confirms that the risk of developing symptomatic radiation injury after radiosurgery is related to lesion diameter and volume and irradiated volume. Results suggest a higher tolerance than proposed by QUANTEC. The widely differing findings reported in the literature, however, raise considerable uncertainties.

  16. Factors Predictive of Symptomatic Radiation Injury After Linear Accelerator-Based Stereotactic Radiosurgery for Intracerebral Arteriovenous Malformations

    Energy Technology Data Exchange (ETDEWEB)

    Herbert, Christopher, E-mail: cherbert@bccancer.bc.ca [Department of Radiation Oncology, British Columbia Cancer Agency, Vancouver, BC (Canada); Moiseenko, Vitali [Department of Medical Physics, British Columbia Cancer Agency, Vancouver, BC (Canada); McKenzie, Michael [Department of Radiation Oncology, British Columbia Cancer Agency, Vancouver, BC (Canada); Redekop, Gary [Division of Neurosurgery, Vancouver General Hospital, University of British Columbia, Vancouver, BC (Canada); Hsu, Fred [Department of Radiation Oncology, British Columbia Cancer Agency, Abbotsford, BC (Canada); Gete, Ermias; Gill, Brad; Lee, Richard; Luchka, Kurt [Department of Medical Physics, British Columbia Cancer Agency, Vancouver, BC (Canada); Haw, Charles [Division of Neurosurgery, Vancouver General Hospital, University of British Columbia, Vancouver, BC (Canada); Lee, Andrew [Department of Neurosurgery, Royal Columbian Hospital, New Westminster, BC (Canada); Toyota, Brian [Division of Neurosurgery, Vancouver General Hospital, University of British Columbia, Vancouver, BC (Canada); Martin, Montgomery [Department of Medical Imaging, British Columbia Cancer Agency, Vancouver, BC (Canada)

    2012-07-01

    Purpose: To investigate predictive factors in the development of symptomatic radiation injury after treatment with linear accelerator-based stereotactic radiosurgery for intracerebral arteriovenous malformations and relate the findings to the conclusions drawn by Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC). Methods and Materials: Archived plans for 73 patients who were treated at the British Columbia Cancer Agency were studied. Actuarial estimates of freedom from radiation injury were calculated using the Kaplan-Meier method. Univariate and multivariate Cox proportional hazards models were used for analysis of incidence of radiation injury. Log-rank test was used to search for dosimetric parameters associated with freedom from radiation injury. Results: Symptomatic radiation injury was exhibited by 14 of 73 patients (19.2%). Actuarial rate of symptomatic radiation injury was 23.0% at 4 years. Most patients (78.5%) had mild to moderate deficits according to Common Terminology Criteria for Adverse Events, version 4.0. On univariate analysis, lesion volume and diameter, dose to isocenter, and a V{sub x} for doses {>=}8 Gy showed statistical significance. Only lesion diameter showed statistical significance (p < 0.05) in a multivariate model. According to the log-rank test, AVM volumes >5 cm{sup 3} and diameters >30 mm were significantly associated with the risk of radiation injury (p < 0.01). The V{sub 12} also showed strong association with the incidence of radiation injury. Actuarial incidence of radiation injury was 16.8% if V{sub 12} was <28 cm{sup 3} and 53.2% if >28 cm{sup 3} (log-rank test, p = 0.001). Conclusions: This study confirms that the risk of developing symptomatic radiation injury after radiosurgery is related to lesion diameter and volume and irradiated volume. Results suggest a higher tolerance than proposed by QUANTEC. The widely differing findings reported in the literature, however, raise considerable uncertainties.

  17. Predictors of Distant Brain Recurrence for Patients With Newly Diagnosed Brain Metastases Treated With Stereotactic Radiosurgery Alone

    International Nuclear Information System (INIS)

    Sawrie, Stephen M.; Guthrie, Barton L.; Spencer, Sharon A.; Nordal, Robert A.; Meredith, Ruby F.; Markert, James M.; Cloud, Gretchen A.; Fiveash, John B.

    2008-01-01

    Purpose: To ascertain predictors of distant brain failure (DBF) in patients treated initially with stereotactic radiosurgery alone for newly diagnosed brain metastases. We hypothesize that these factors may be used to group patients according to risk of DBF. Methods and Materials: We retrospectively analyzed 100 patients with newly diagnosed brain metastases treated from 2003 to 2005 at our Gamma Knife radiosurgery facility. The primary endpoint was DBF. Potential predictors included number of metastases, tumor volume, histologic characteristics, extracranial disease, and use of temozolomide. Results: One-year actuarial risk of DBF was 61% for all patients. Significant predictors of DBF included more than three metastases (hazard ratio, 3.30; p = 0.004), stable or poorly controlled extracranial disease (hazard ratio, 2.16; p = 0.04), and melanoma histologic characteristics (hazard ratio, 2.14; p = 0.02). These were confirmed in multivariate analysis. Those with three or fewer metastases, no extracranial disease, and nonmelanoma histologic characteristics (N = 18) had a median time to DBF of 89 weeks vs. 33 weeks for all others. One-year actuarial freedom from DBF for this group was 83% vs. 26% for all others. Conclusions: Independent significant predictors of DBF in our series included number of metastases (more than three), present or uncontrolled extracranial disease, and melanoma histologic characteristics. These factors were combined to identify a lower risk subgroup with significantly longer time to DBF. These patients may be candidates for initial localized treatment, reserving whole-brain radiation therapy for salvage. Patients in the higher risk group may be candidates for initial whole-brain radiation therapy or should be considered for clinical trials

  18. Linear accelerator radiosurgery for arteriovenous malformations: Updated literature review.

    Science.gov (United States)

    Yahya, S; Heyes, G; Nightingale, P; Lamin, S; Chavda, S; Geh, I; Spooner, D; Cruickshank, G; Sanghera, P

    2017-04-01

    Arteriovenous malformations (AVMs) are the leading causing of intra-cerebral haemorrhage. Stereotactic radiosurgery (SRS) is an established treatment for arteriovenous malformations (AVM) and commonly delivered using Gamma Knife within dedicated radiosurgery units. Linear accelerator (LINAC) SRS is increasingly available however debate remains over whether it offers an equivalent outcome. The aim of this project is to evaluate the outcomes using LINAC SRS for AVMs used within a UK neurosciences unit and review the literature to aid decision making across various SRS platforms. Results have shown comparability across platforms and strongly supports that an adapted LINAC based SRS facility within a dynamic regional neuro-oncology department delivers similar outcomes (in terms of obliteration and toxicity) to any other dedicated radio-surgical platform. Locally available facilities can facilitate discussion between options however throughput will inevitably be lower than centrally based dedicated national radiosurgery units. Copyright © 2016. Published by Elsevier Ltd.

  19. CHARGED PARTICLE MULTIPLICITIES IN ULTRA-RELATIVISTIC AU+AU AND CU+CU COLLISIONS

    Science.gov (United States)

    Back, B. B.; Alver, B.; Back, B. B.; Baker, M. D.; Ballintijn, M.; Barton, D. S.; Betts, R. R.; Bickley, A. A.; Bindel, R.; Busza, W.; Carroll, A.; Chai, Z.; Chetluru, V.; Decowski, M. P.; Garcia, E.; Gburek, T.; George, N.; Gulbrandsen, K.; Halliwell, C.; Hamblen, J.; Harnarine, I.; Hauer, M.; Henderson, C.; Hofman, D. J.; Hollis, R. S.; Holynski, R.; Holzman, B.; Iordanova, A.; Johnson, E.; Kane, J. L.; Khan, N.; Kulinich, P.; Kuo, C. M.; Li, W.; Lin, W. T.; Loizides, C.; Manly, S.; Mignerey, A. C.; Nouicer, R.; Olszewski, A.; Pak, R.; Reed, C.; Richardson, E.; Roland, C.; Roland, G.; Sagerer, J.; Seals, H.; Sedykh, I.; Smith, C. E.; Stankiewicz, M. A.; Steinberg, P.; Stephans, G. S. F.; Sukhanov, A.; Szostak, A.; Tonjes, M. B.; Trzupek, A.; Vale, C.; Vannieuwenhuizen, G. J.; Vaurynovich, S. S.; Verdier, R.; Veres, G. I.; Walters, P.; Wenger, E.; Willhelm, D.; Wolfs, F. L. H.; Wosiek, B.; Wozniak, K.; Wyngaardt, S.; Wyslouch, B.

    The PHOBOS collaboration has carried out a systematic study of charged particle multiplicities in Cu+Cu and Au+Au collisions at the Relativistic Heavy-Ion Collider (RHIC) at Brookhaven National Laboratory. A unique feature of the PHOBOS detector is its ability to measure charged particles over a very wide angular range from 0.5° to 179.5° corresponding to |η| <5.4. The general features of the charged particle multiplicity distributions as a function of pseudo-rapidity, collision energy and centrality, as well as system size, are discussed.

  20. Heavy particle track structure parameters for biophysical modelling

    International Nuclear Information System (INIS)

    Watt, D.E.

    1994-01-01

    Averaged values of physical track structure parameters are important in radiobiology and radiological protection for the expression of damage mechanisms and for quantifying radiation effects. To provide a ready reference, tables of relevant quantities have been compiled for heavy charged particles in liquid water. The full tables will be published elsewhere but here illustrative examples are given of the trends for the most important quantities. In the tables, data are given for 74 types of heavy charged particle ranging from protons to uranium ions at specific energies between 0.1 keV/u and 1 GeV/u. Aggregate effects in liquid water are taken into account implicitly in the calculations. Results are presented for instantaneous particle energies and for averages over the charged particle equilibrium spectrum. The latter are of special relevance to radiation dosimetry. Quality parameters calculated are: β 2 ; z 2 /β 2 ; linear primary ionisation and the mean free path between ionisations; LET; track and dose-restricted LET with 100 eV cut-off; relative variances; delta-ray energies and ranges; ion energies and ranges and kerma factors. Here, the procedures used in the calculations are indicated. Representative results are shown in graphical form. The role of the physical track properties is discussed with regard to optimisation of the design of experiments intended to elucidate biological damage mechanisms in mammalian cells and their relevance to radiological protection. ((orig.))

  1. Immediate side effects of stereotactic radiotherapy and radiosurgery

    International Nuclear Information System (INIS)

    Werner-Wasik, Maria; Rudoler, Shari; Preston, Peter E.; Hauck, Walter W.; Downes, Beverly M.; Leeper, Dennis; Andrews, David; Corn, Benjamin W.; Curran, Walter J.

    1999-01-01

    Purpose: Despite increased utilization of fractionated stereotactic radiation therapy (SRT) or stereotactic radiosurgery (SRS), the incidence and nature of immediate side effects (ISE) associated with these treatment techniques are not well defined. We report immediate side effects from a series of 78 patients. Materials and Methods: Intracranial lesions in 78 adult patients were treated with SRT or SRS, using a dedicated linear accelerator. Those lesions included 13 gliomas, 2 ependymomas, 19 metastatic tumors, 15 meningiomas, 12 acoustic neuromas, 4 pituitary adenomas, 1 optic neuroma, 1 chondrosarcoma, and 11 arteriovenous malformations (AVM). SRT was used in 51 and SRS in 27 patients. Mean target volume was 9.0 cc. Eleven patients received prior external-beam radiation therapy within 2 months before SRT/SRS. Any side effects occurring during and up to 2 weeks after the course of radiation were defined as ISE and were graded as mild, moderate, or severe. The incidence of ISE and the significance of their association with several treatment and pretreatment variables were analyzed. Results: Overall, 28 (35%) of 78 patients experienced one or more ISE. Most of the ISE (87%) were mild, and consisted of nausea (in 5), dizziness/vertigo (in 5), seizures (in 6), and new persistent headaches (in 17). Two episodes of worsening neurological deficit and 2 of orbital pain were graded as moderate. Two patients experienced severe ISE, requiring hospitalization (1 seizure and 1 worsening neurological deficit). ISE in 6 cases prompted computerized tomography of the brain, which revealed increased perilesional edema in 3 cases. The incidence of ISE by diagnosis was as follows: 46% (6 of 13) for gliomas, 50% (6 of 12) for acoustic neuromas, 36% (4 of 11) for AVM, 33% (5 of 15) for meningiomas, and 21% (4 of 19) for metastases. A higher incidence of dizziness/vertigo (4 of 12 = 33%) was seen among acoustic neuroma patients than among other patients (p < 0.01). There was no

  2. Measurement of heavy particle and isotope

    International Nuclear Information System (INIS)

    Matsuoka, Masaru; Kohno, Takeshi; Imai, Takashi; Munakata, Kazuoki

    1987-01-01

    The report describes some achievements made so far in developing heavy particle and isotope measuring equipment that is planned to be mounted on the No.6 technical test satelite of the National Space Development Agency, ETS VI. Some ideas are proposed for such heavy particle and isotope measuring equipment that uses Astromag. The structure of SSD is shown which is planned to be incorporated in the sensor for the equipment. The planned charged particle detector consists of position sensitive detectors, PIN diodes and Si(Li) plates. Tests are made for the basic characteristics of such a detector. The characteristics of a PSD are also investigated. The PSD has a resolution of about 1 mm for 14 MeV He. Tests of a 0.3 mm PIN diode and 1.2 mm Si(Li) is carried out with 234 MeV-nucl Fe beams to determine their pulse height distribution. The PIN diode and Si(Li) are found to have a resolution of 6.79 and 17.6 MeV for energy loss of 158 and 710 MeV, respectively. If developed, a stripe-type Si PIN diode will serve for analysis of isotopes. A conceptual diagram of such a stripe device is proposed. The mechanism of measurement by a heavy particle and isotope detecting system incorporating Astromag is also illustrated. (Nogami, K.)

  3. Stereotactic Fractionated Radiotherapy and LINAC Radiosurgery in the Treatment of Vestibular Schwannoma-Report About Both Stereotactic Methods From a Single Institution

    International Nuclear Information System (INIS)

    Kopp, Christine; Fauser, Claudius; Mueller, Axel; Astner, Sabrina T.; Jacob, Vesna; Lumenta, Christianto; Meyer, Bernhard; Tonn, Joerg-Christian; Molls, Michael; Grosu, Anca-Ligia

    2011-01-01

    Purpose: To evaluate tumor control and side effects associated with radiosurgery (RS) and stereotactic fractionated radiotherapy (SFR) for vestibular schwannomas (VSs) in a group of patients treated at the same institution. Methods and Materials: Between May 1997 and June 2007, 115 consecutive cases of VS were treated in our department. The SFR group (47 patients), including larger tumors (maximum diameter >1.5 cm), received a total dose of 54 Gy at 1.8 Gy per fraction. The RS group (68 patients, maximum diameter <1.5 cm) received a total dose of 12 Gy at the 100% isodose. Evaluation included serial imaging tests (magnetic resonance imaging) and neurologic and functional hearing examinations. Results: The tumor control rate was 97.9% in the SFR group for a mean follow-up time of 32.1 months and 98.5% in the RS group for a mean follow-up time of 30.1 months. Hearing function was preserved after RS in 85% of the patients and after SFR in 79%. Facial and trigeminal nerve function remained mostly unaffected after SFR. After RS, new trigeminal neuropathy occurred in 9 of 68 patients (13%). Conclusions: A high tumor control rate and low number of side effects are registered after SFR and RS of VS. These results confirm that considering tumor diameter, both RS and SFR are good treatment modalities for VS.

  4. Multiple photon emission in heavy particle decays

    International Nuclear Information System (INIS)

    Asakimori, K.; Burnett, T.H.; Cherry, M.L.

    1994-03-01

    Cosmic ray interactions, at energies above 1 TeV/nucleon, in emulsion chambers flown on high altitude balloons have yielded two events showing apparent decays of a heavy particle into one charged particle and four photons. The photons converted into electron pairs very close to the decay vertex. Attempts to explain this decay topology with known particle decays are presented. Unless both events represent a b → u transition, which is statistically unlikely, then other known decay modes for charmed or bottom particles do not account satisfactorily for these observations. This could indicate, possibly, a new decay channel. (author). 7 refs, 6 figs, 2 tabs

  5. A facility for low energy charged particle induced reaction studies

    International Nuclear Information System (INIS)

    Vilaithong, T.; Singkarat, S.; Yu, L.D.; Intarasiri, S.; Tippawan, U.

    2000-01-01

    In Chiang Mai, a highly stable low energy ion accelerator (0 - 350 kV) facility is being established. A subnano-second pulsing system will be incorporated into the beam transport line. The detecting system will consist of a time-of-flight charged particle spectrometer and a high resolution gamma-ray system. The new facility will be used in the studies of low energy heavy ion backscattering and charged particle induced cross section measurement in the interests of material characterization and nucleosynthesis. (author)

  6. Stereotactic radiosurgery for brain metastases

    International Nuclear Information System (INIS)

    Obedian, E.; Lotbiniere, A.C.J. de; Haffty, B.G.; Piepmeier, J.M.; Fischer, D.B.; Knisely, J.P.S.

    1997-01-01

    Purpose: This study evaluates the influence of several prognostic factors on overall survival and progression free survival in patients undergoing stereotactic radiosurgery (SRS) for brain metastases. Materials and Methods: Records of 61 coecutive patients with pathologically confirmed extra-cranial malignancies undergoing SRS at Yale University School of Medicine between 12/18/91 and 7/2/96 were reviewed. All patients underwent head frame localization and CT and/or MRI based treatment planning. Outcome was analyzed with respect to age, number of lesions, size of lesions, location of lesions, site and stage of primary tumor, status of primary tumor at time of SRS, history of whole brain radiation therapy (WBRT), surgery, and/or chemotherapy prior to or after SRS, delay in SRS from diagnosis of brain metastases, dose of radiation delivered, and brain metastasis free interval. Both overall survival and progression free survival were analyzed by the Kaplan-Meier method. Tests for statistical significance were performed using the Cox proportional hazards model. Results: Median follow-up was 29 months. 3% ((8(61))) of patients displayed evidence of progressive disease at the site of SRS, and 87% ((53(61))) of patients have died. Overall and progression free survival rates for the entire cohort of patients were 43.8% and 89.5% at 1 year and 11.1% and 71.4% at 2 years, respectively. Patients undergoing SRS for a solitary brain metastasis had a significant improvement in overall survival with 1 year survival rates of 52.6% vs. 32.7% for patients undergoing SRS for more than 1 brain metastasis (p=0.002). Patients who presented with progressive systemic disease at the time of SRS had an inferior overall survival with a 1 year survival rate of 15.4% compared to patients with presumed/known stable disease who had a 1 year survival rate of 51.5%/54.2% (p<0.001). Patients treated for cerebral metastases had a higher progression free survival compared to patients undergoing SRS

  7. The university of Florida frameless high-precision stereotactic radiotherapy system

    International Nuclear Information System (INIS)

    Bova, Francis J.; Buatti, John M.; Friedman, William A.; Mendenhall, William M.; Yang, Ching-Chong; Liu, Chihray

    1997-01-01

    Purpose: To develop and test a system for high precision fractionated stereotactic radiotherapy that separates immobilization and localization devices. Methods and Materials: Patient localization is achieved through detection and digital registration of an independent bite plate system. The bite plate is made and linked to a set of six infrared light emitting diodes (IRLEDs). These IRLEDs are detected by an infrared camera system that identifies the position of each IRLED within 0.1 to 0.15 mm. Calibration of the camera system defines isocenter and translational X, Y, and Z axes of the stereotactic radiosurgery subsystem and thereby digitally defines the virtual treatment room space in a computer linked to the camera system. Positions of the bite plate's IRLEDs are processed digitally using a computer algorithm so that positional differences between an actual bite plate position and a desired position can be resolved within 0.1 mm of translation (X, Y, and Z distance) and 0.1 degree of rotation. Furthermore, bite plate misalignment can be displayed digitally in real time with translational (x, y, and z) and rotational (roll, pitch, and yaw) parameters for an actual bite plate position. Immobilization is achieved by a custom head mold and thermal plastic mask linked by hook-and-loop fastener tape. The head holder system permits rotational and translational movements for daily treatment positioning based on the bite plate localization system. Initial testing of the localization system was performed on 20 patients treated with radiosurgery. The system was used to treat 11 patients with fractionated stereotactic radiotherapy. Results: Assessment of bite plate localization in radiosurgery patients revealed that the patient's bite plate could be positioned and repositioned within 0.5 ± 0.3 mm (standard deviation). After adjustments, the first 11 patients were treated with the bite plate repositioning error reduced to 0.2 ± 0.1 mm. Conclusions: High precision

  8. Determination of gonad doses during robotic stereotactic radiosurgery for various tumor sites

    International Nuclear Information System (INIS)

    Zorlu, Faruk; Dugel, Gozde; Ozyigit, Gokhan; Hurmuz, Pervin; Cengiz, Mustafa; Yildiz, Ferah; Akyol, Fadil; Gurkaynak, Murat

    2013-01-01

    Purpose: The authors evaluated the absorbed dose received by the gonads during robotic stereotactic radiosurgery (SRS) for the treatment of different tumor localizations. Methods: The authors measured the gonad doses during the treatment of head and neck, thoracic, abdominal, or pelvic tumors in both RANDO phantom and actual patients. The computerized tomography images were transferred to the treatment planning system. The contours of tumor and critical organs were delineated on each slice, and treatment plans were generated. Measurements for gonad doses were taken from the geometric projection of the ovary onto the skin for female patients, and from the scrotal skin for male patients by attaching films and Thermoluminescent dosimeters (TLDs). SRS was delivered with CyberKnife (Accuray Inc., Sunnyvale, CA). Results: The median gonadal doses with TLD and film dosimeter in actual patients were 0.19 Gy (range, 0.035–2.71 Gy) and 0.34 Gy (range, 0.066–3.18 Gy), respectively. In the RANDO phantom, the median ovarian doses with TLD and film dosimeter were 0.08 Gy (range, 0.03–0.159 Gy) and 0.05 Gy (range, 0.015–0.13 Gy), respectively. In the RANDO phantom, the median testicular doses with TLD and film dosimeter were 0.134 Gy (range 0.056–1.97 Gy) and 0.306 Gy (range, 0.065–2.25 Gy). Conclusions: Gonad doses are below sterility threshold in robotic SRS for different tumor localizations. However, particular attention should be given to gonads during robotic SRS for pelvic tumors.

  9. Determination of gonad doses during robotic stereotactic radiosurgery for various tumor sites

    Energy Technology Data Exchange (ETDEWEB)

    Zorlu, Faruk; Dugel, Gozde; Ozyigit, Gokhan; Hurmuz, Pervin; Cengiz, Mustafa; Yildiz, Ferah; Akyol, Fadil; Gurkaynak, Murat [Hacettepe University Faculty of Medicine, Department of Radiation Oncology, Ankara 06100 (Turkey)

    2013-04-15

    Purpose: The authors evaluated the absorbed dose received by the gonads during robotic stereotactic radiosurgery (SRS) for the treatment of different tumor localizations. Methods: The authors measured the gonad doses during the treatment of head and neck, thoracic, abdominal, or pelvic tumors in both RANDO phantom and actual patients. The computerized tomography images were transferred to the treatment planning system. The contours of tumor and critical organs were delineated on each slice, and treatment plans were generated. Measurements for gonad doses were taken from the geometric projection of the ovary onto the skin for female patients, and from the scrotal skin for male patients by attaching films and Thermoluminescent dosimeters (TLDs). SRS was delivered with CyberKnife (Accuray Inc., Sunnyvale, CA). Results: The median gonadal doses with TLD and film dosimeter in actual patients were 0.19 Gy (range, 0.035-2.71 Gy) and 0.34 Gy (range, 0.066-3.18 Gy), respectively. In the RANDO phantom, the median ovarian doses with TLD and film dosimeter were 0.08 Gy (range, 0.03-0.159 Gy) and 0.05 Gy (range, 0.015-0.13 Gy), respectively. In the RANDO phantom, the median testicular doses with TLD and film dosimeter were 0.134 Gy (range 0.056-1.97 Gy) and 0.306 Gy (range, 0.065-2.25 Gy). Conclusions: Gonad doses are below sterility threshold in robotic SRS for different tumor localizations. However, particular attention should be given to gonads during robotic SRS for pelvic tumors.

  10. Analysis of metabolic change by Tl-201 SPECT in brain tumors treated with stereotactic radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Sugo, Nobuo [Toho Univ., Tokyo (Japan). School of Medicine

    1996-03-01

    The time course for changes in Tl-201 uptake and tumor size was studied correlatively. A total of 24 cases of brain tumors was enrolled in the study. Three detector type scanner, PRISM 3000 was used. SPECT scanning was started 10 min after intravenous administration of 111 MBq of Tl-201, and sequentially repeated every 1 min for 16 min. Tl-201 radioactivity was counted in two regions of interest (ROI). One was an area encircling the tumor, and the other, an area in the contralateral hemisphere that served as control. Tl index (TI) was calculated by this formula: TI=T-C/C, where T is the count in the tumor and C, the count in the control area. The size of a given tumor was represented by its maximum diameter as determined by CT or MRI. The TI and the tumor size were compared before and after radiosurgery. In all cases, a decrease in TI was seen earlier than a reduction in tumor size. Among malignant tumors, the TI decrease took place as early as one week, and rapidly reached the lowest level. On the other hand, in benign tumors, it took as long as 6 to 12 months for the decrease of the TI to be evident; the subsequent was very slow. The difference between malignant and benign tumors of the brain is attributed to the fact that high dose irradiation of the malignant, radiosensitive tumors causes deep disturbances in cell metabolism that lead to cell death. By contrast, irradiation of a benign tumor with low radiosensitivity does not affect the cellular metabolism, but injures the vascular wall, leading to gradual stenosis or obliteration of the vessels in the tumor. These data strongly suggest that the rapid and marked decrease of malignant tumors after stereotactic radiosurgery is the result of a direct injury to the malignant cells, and that the rather slow and insufficient diminution of benign tumors can be attributed to diminished blood supply to the tumor. (author)

  11. A hybrid charged-particle guide for studying (n, charged particle) reactions

    International Nuclear Information System (INIS)

    Haight, R.C.; White, R.M.; Zinkle, S.J.

    1983-01-01

    Charged-particle transport systems consisting of magnetic quadrupole lenses have been employed in recent years in the study of (n, charged particle) reactions. A new transport system was completed at the laboratory that is based both on magnetic lenses as well as electrostatic fields. The magnetic focusing of the charged-particle guide is provided by six magnetic quadrupole lenses arranged in a CDCCDC sequence (in the vertical plane). The electrostatic field is produced by a wire at high voltage which stretches the length of the guide and is physically at the centre of the magnetic axis. The magnetic lenses are used for charged particles above 5 MeV; the electrostatic guide is used for lower energies. This hybrid system possesses the excellent focusing and background rejection properties of other magnetic systems. For low energy charged-particles, the electrostatic transport avoids the narrow band-passes in charged-particle energy which are a problem with purely magnetic transport systems. This system is installed at the LLNL Cyclograaff facility for the study of (n, charged particle) reactions at neutron energies up to 35 MeV. (Auth.)

  12. Single-session Gamma Knife radiosurgery for optic pathway/hypothalamic gliomas.

    Science.gov (United States)

    El-Shehaby, Amr M N; Reda, Wael A; Abdel Karim, Khaled M; Emad Eldin, Reem M; Nabeel, Ahmed M

    2016-12-01

    OBJECTIVE Because of their critical and central location, it is deemed necessary to fractionate when considering irradiating optic pathway/hypothalamic gliomas. Stereotactic fractionated radiotherapy is considered safer when dealing with gliomas in this location. In this study, the safety and efficacy of single-session stereotactic radiosurgery for optic pathway/hypothalamic gliomas were reviewed. METHODS Between December 2004 and June 2014, 22 patients with optic pathway/hypothalamic gliomas were treated by single-session Gamma Knife radiosurgery. Twenty patients were available for follow-up for a minimum of 1 year after treatment. The patients were 5 to 43 years (median 16 years) of age. The tumor volume was 0.15 to 18.2 cm 3 (median 3.1 cm 3 ). The prescription dose ranged from 8 to 14 Gy (median 11.5 Gy). RESULTS The mean follow-up period was 43 months. Five tumors involved the optic nerve only, and 15 tumors involved the chiasm/hypothalamus. Two patients died during the follow-up period. The tumors shrank in 12 cases, remained stable in 6 cases, and progressed in 2 cases, thereby making the tumor control rate 90%. Vision remained stable in 12 cases, improved in 6 cases, and worsened in 2 cases in which there was tumor progression. Progression-free survival was 83% at 3 years. CONCLUSIONS The initial results indicate that single-session Gamma Knife radiosurgery is a safe and effective treatment option for optic pathway/hypothalamic gliomas.

  13. SU-F-T-212: A Comparison of Treatment Strategies for Intracranial Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Lamberton, T; Slater, J; Wroe, A

    2016-01-01

    Purpose: Stereotactic radiosurgery is an effective and noninvasive treatment for intracranial lesions that uses highly focused radiation beams in a single treatment fraction. The purpose of this study is to investigate the dosimetric differences between the treatment brain metastasis with a proton beam vs. intensity modulated radiation therapy (IMRT). Methods: Ten separate brain metastasis targets where chosen and treatment plans were created for each, using three different strategies: custom proton beam shaping devices, standardized proton beam shaping devices, and IMRT. Each plan was required to satisfy set parameters for providing adequate coverage and minimizing risk to adjacent tissues. The effectiveness of each plan was calculated by comparing the homogeneity index, conformity index, and V12 for each target using a paired one tailed T-test (α=0.05). Specific comparison of the conformity indices was also made using a subcategory containing targets with volume>1cc. Results: There was no significant difference between the homogeneity indices of the three plans (p>0.05), showing that each plan has the capability of adequately covering the targets. There was a statistically significant difference (p 1cc) there was no statistical difference between the proton plans and the IMRT treatment for the conformity index. Conclusion: A custom proton plan is the recommended treatment explored in this study as it is the most reliable way of effectively treating the target while sparing the maximum amount of normal tissue.

  14. Search for Heavy Long-Lived Particles in ATLAS

    CERN Document Server

    Kajomovitz, Enrique

    This thesis presents a search for long-lived particles through a measuremt of their mass performed on a data sample of \\lumi from proton-proton collisions at a centre-of-mass energy $\\sqrt{s} = 7~\\TeV$ collected by the ATLAS detector at the LHC in 2011. The mass of the long-lived particles is estimated from a measurement of their speed, $\\beta$, and their momentum measurements using the relation $m=p/\\beta\\gamma$. Two distinct types of LLPs are sought after; sleptons, the supersymmetric partners of the Standard Model leptons, and \\rhads, colorless bound states that include a colored supersymmetric long-lived particle in addition to colored Standard Model particles. Sleptons are expected to interact with the detector as if they were heavy muons, charged throughout the detector and penetrating. In contrast, \\rhads~may change charge in the detector due to the strong interactions between the light quarks in the \\rhads~with the detector material. Thus, \\rhads~may be charged in the ID and neutral in the MS or...

  15. Charge-sign-clustering observed in high-multiplicity, high-energy heavy-ion collisions

    International Nuclear Information System (INIS)

    Takahashi, Y.; Gregory, J.C.; Hayashi, T.

    1989-01-01

    Charge-sign distribution in 200 GeV/amu heavy-ion collisions is studied with the Magnetic-Interferometric-Emulsion-Chamber (MAGIC) for central collision events in 16 O + Pb and 32 S + Pb interactions. Charge-sign clustering is observed in most of the fully-analyzed events. A statistical 'run-test' is performed for each measured event, which shows significant deviation from a Gaussian distribution (0,1) expected for random-charge distribution. Candidates of charge clusters have 5 - 10 multiplicity of like-sign particles, and are often accompanied by opposite-sign clusters. Observed clustering of identical charges is more significant in the fragmentation region than in the central region. Two-particle Bose-Einstein interference and other effects are discussed for the run-test examination. (author)

  16. Charged particle activation analysis: present status and future perspectives

    International Nuclear Information System (INIS)

    Chowdhury, D.P.

    2006-01-01

    Charged particle activation analysis is a highly sensitive nuclear analytical technique for the determination of elements at trace and ultra trace levels. CPAA involves the irradiation of samples with high energy charged particles, both light ions and heavy ions, from an accelerator in the energy range of 10 to 100 MeV. CPAA has been developed and standardized for the determination of several elements at trace levels in various types of materials using high energy ion beams from VEC machine at Kolkata. A brief review on CPAA is presented here based on our present works and its applications in future. (author)

  17. [Linear accelerator-based stereotactic radiosurgery for the treatment of trigeminal neuralgia. Nine years' experience in a single institution].

    Science.gov (United States)

    Serrano-Rubio, A A; Martinez-Manrique, J J; Revuelta-Gutierrez, R; Gomez-Amador, J L; Martinez-Anda, J J; Ponce-Gomez, J A; Moreno-Jimenez, S

    2014-09-16

    INTRODUCTION. Pharmacological treatment is the first therapeutic step towards controlling pain in trigeminal neuralgia, but 25-50% of patients become medication resistant. There are currently several surgical alternatives for treating these patients. AIM. To evaluate the effectiveness and safety of stereotactic radiosurgery for the treatment of patients with trigeminal neuralgia. PATIENTS AND METHODS. A follow-up study was conducted on 30 patients who underwent radiosurgery using a Novalis linear accelerator. Eighty per cent of the dosage was calculated at the isocentre, the entry zone of the root of the trigeminal nerve. The mean follow-up time was 27.5 months (range: 1-65 months). RESULTS. The mean age was 66 years (range: 36-87 years), with a time to progression of 7.1 years (range: 4-27 years). The distribution of the pain was from the right side (63.3%). Of the 30 patients, 27 experienced an improvement (90%) 1.6 months (range: 1 week-4 months) after the treatment; 10 patients (33.3%) scored grade I, and 17 patients (56.6%) obtained a score of grade II. During the follow-up, four patients (14.2%) suffered a relapse; two underwent re-irradiation. Time without recurrence was 62.7 months (range: 54.6-70.8 months). The rate of side effects was 76.7% and only three patients developed facial anaesthesia with loss of the corneal reflex. CONCLUSIONS. The use of the linear accelerator is an effective therapeutic option in the treatment of trigeminal neuralgia, since it provides adequate long-term control of the pain, reduces the use of medication and improves the quality of life.

  18. TH-A-BRC-01: AAPM TG-135U1 QA for Robotic Radiosurgery

    International Nuclear Information System (INIS)

    Dieterich, S.

    2016-01-01

    AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline

  19. TH-A-BRC-01: AAPM TG-135U1 QA for Robotic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Dieterich, S. [UC Davis Medical Center (United States)

    2016-06-15

    AAPM TG-135U1 QA for Robotic Radiosurgery - Sonja Dieterich Since the publication of AAPM TG-135 in 2011, the technology of robotic radiosurgery has rapidly developed. AAPM TG-135U1 will provide recommendations on the clinical practice for using the IRIS collimator, fiducial-less real-time motion tracking, and Monte Carlo based treatment planning. In addition, it will summarize currently available literature about uncertainties. Learning Objectives: Understand the progression of technology since the first TG publication Learn which new QA procedures should be implemented for new technologies Be familiar with updates to clinical practice guidelines AAPM TG-178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance - Steven Goetsch Purpose: AAPM Task Group 178 Gamma Stereotactic Radiosurgery Dosimetry and Quality Assurance was formed in August, 2008. The Task Group has 12 medical physicists, two physicians and two consultants. Methods: A round robin dosimetry intercomparison of proposed ionization chambers, electrometer and dosimetry phantoms was conducted over a 15 month period in 2011 and 2012 (Med Phys 42, 11, Nov, 2015). The data obtained at 9 institutions (with ten different Elekta Gamma Knife units) was analyzed by the lead author using several protocols. Results: The most consistent results were obtained using the Elekta ABS 16cm diameter phantom, with the TG-51 protocol modified as recommended by Alfonso et al (Med Phys 35, 11, Nov 2008). A key white paper (Med Phys, in press) sponsored by Elekta Corporation, was used to obtain correction factors for the ionization chambers and phantoms used in this intercomparison. Consistent results were obtained for both Elekta Gamma Knife Model 4C and Gamma Knife Perfexion units as measured with each of two miniature ionization chambers. Conclusion: The full report gives clinical history and background of gamma stereotactic radiosurgery, clinical examples and history, quality assurance recommendations and outline

  20. Intra-arterial angio-CT for radiosurgery of cerebral arteriovenous malformations

    International Nuclear Information System (INIS)

    Tanami, Yutaka; Kunieda, Etsuo; Onozuka, Satoshi

    1998-01-01

    Intra-arterial CT-angiograms were performed for four patients undergoing stereotactic radiosurgery for cerebral arteriovenous malformations (AVM). Helical and dynamic CT scans were carried out with a scanner installed in a angiographic examination room following routine angiography. Helical scans were performed with continuous arterial infusion of contrast media. Then, dynamic scans were repeated at several table positions. Subtractions were achieved for a post-embolization case. Normal and pathological vascular structures were demonstrated with different enhancement phases with the dynamic scans. The coordinates of the target points in the nidus could be clearly determined. We concluded that intra-arterial CT-angiograms are practical and useful for treatment planning of radiosurgery for cerebral AVM. (author)

  1. Intra-arterial angio-CT for radiosurgery of cerebral arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Tanami, Yutaka; Kunieda, Etsuo; Onozuka, Satoshi [Keio Univ., Tokyo (Japan) School of Medicine] [and others

    1998-08-01

    Intra-arterial CT-angiograms were performed for four patients undergoing stereotactic radiosurgery for cerebral arteriovenous malformations (AVM). Helical and dynamic CT scans were carried out with a scanner installed in a angiographic examination room following routine angiography. Helical scans were performed with continuous arterial infusion of contrast media. Then, dynamic scans were repeated at several table positions. Subtractions were achieved for a post-embolization case. Normal and pathological vascular structures were demonstrated with different enhancement phases with the dynamic scans. The coordinates of the target points in the nidus could be clearly determined. We concluded that intra-arterial CT-angiograms are practical and useful for treatment planning of radiosurgery for cerebral AVM. (author)

  2. Stereotactic radiosurgery XX: ocular neuromyotonia in association with gamma knife radiosurgery

    Science.gov (United States)

    McQuillan, Joe; Plowman, P Nicholas; MacDougall, Niall; Blackburn, Philip; Sabin, H Ian; Ali, Nadeem; Drake, William M

    2015-01-01

    Summary We report three patients who developed symptoms and signs of ocular neuromyotonia (ONM) 3–6 months after receiving gamma knife radiosurgery (GKS) for functioning pituitary tumours. All three patients were complex, requiring multi-modality therapy and all had received prior external irradiation to the sellar region. Although direct causality cannot be attributed, the timing of the development of the symptoms would suggest that the GKS played a contributory role in the development of this rare problem, which we suggest clinicians should be aware of as a potential complication. Learning points GKS can cause ONM, presenting as intermittent diplopia.ONM can occur quite rapidly after treatment with GKS.Treatment with carbamazepine is effective and improve patient's quality of life. PMID:26294961

  3. Verification of gamma knife based fractionated radiosurgery with newly developed head-thorax phantom

    International Nuclear Information System (INIS)

    Bisht, Raj Kishor; Kale, Shashank Sharad; Natanasabapathi, Gopishankar; Singh, Manmohan Jit; Agarwal, Deepak; Garg, Ajay; Rath, Goura Kishore; Julka, Pramod Kumar; Kumar, Pratik; Thulkar, Sanjay; Sharma, Bhawani Shankar

    2016-01-01

    Objective: Purpose of the study is to verify the Gamma Knife Extend™ system (ES) based fractionated stereotactic radiosurgery with newly developed head-thorax phantom. Methods: Phantoms are extensively used to measure radiation dose and verify treatment plan in radiotherapy. A human upper body shaped phantom with thorax was designed to simulate fractionated stereotactic radiosurgery using Extend™ system of Gamma Knife. The central component of the phantom aids in performing radiological precision test, dosimetric evaluation and treatment verification. A hollow right circular cylindrical space of diameter 7.0 cm was created at the centre of this component to place various dosimetric devices using suitable adaptors. The phantom is made of poly methyl methacrylate (PMMA), a transparent thermoplastic material. Two sets of disk assemblies were designed to place dosimetric films in (1) horizontal (xy) and (2) vertical (xz) planes. Specific cylindrical adaptors were designed to place thimble ionization chamber inside phantom for point dose recording along xz axis. EBT3 Gafchromic films were used to analyze and map radiation field. The focal precision test was performed using 4 mm collimator shot in phantom to check radiological accuracy of treatment. The phantom head position within the Extend™ frame was estimated using encoded aperture measurement of repositioning check tool (RCT). For treatment verification, the phantom with inserts for film and ion chamber was scanned in reference treatment position using X-ray computed tomography (CT) machine and acquired stereotactic images were transferred into Leksell Gammaplan (LGP). A patient treatment plan with hypo-fractionated regimen was delivered and identical fractions were compared using EBT3 films and in-house MATLAB codes. Results: RCT measurement showed an overall positional accuracy of 0.265 mm (range 0.223 mm–0.343 mm). Gamma index analysis across fractions exhibited close agreement between LGP and film

  4. Search for pair-production of long-lived heavy charged particles in $e^+ e^-$ annihilation

    CERN Document Server

    Barate, R.; Decamp, D.; Ghez, Philippe; Goy, C.; Lees, J.P.; Lucotte, A.; Minard, M.N.; Nief, J.Y.; Pietrzyk, B.; Casado, M.P.; Chmeissani, M.; Comas, P.; Crespo, J.M.; Delfino, M.; Fernandez, E.; Fernandez-Bosman, M.; Garrido, L.; Juste, A.; Martinez, M.; Miquel, R.; Mir, L.M.; Orteu, S.; Padilla, C.; Park, I.C.; Pascual, A.; Perlas, J.A.; Riu, I.; Sanchez, F.; Teubert, F.; Colaleo, A.; Creanza, D.; De Palma, M.; Gelao, G.; Iaselli, G.; Maggi, G.; Maggi, M.; Marinelli, N.; Nuzzo, S.; Ranieri, A.; Raso, G.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Tricomi, A.; Zito, G.; Huang, X.; Lin, J.; Ouyang, Q.; Wang, T.; Xie, Y.; Xu, R.; Xue, S.; Zhang, J.; Zhang, L.; Zhao, W.; Abbaneo, D.; Alemany, R.; Bazarko, A.O.; Becker, U.; Bright-Thomas, P.; Cattaneo, M.; Cerutti, F.; Dissertori, G.; Drevermann, H.; Forty, R.W.; Frank, M.; Hagelberg, R.; Hansen, J.B.; Harvey, John; Janot, P.; Jost, B.; Kneringer, E.; Knobloch, J.; Lehraus, I.; Lutters, G.; Mato, P.; Minten, A.; Moneta, L.; Pacheco, A.; Pusztaszeri, J.F.; Ranjard, F.; Rizzo, G.; Rolandi, Gigi; Schlatter, D.; Schmitt, M.; Schneider, O.; Tejessy, W.; Tomalin, I.R.; Wachsmuth, H.; Wagner, A.; Ajaltouni, Z.; Barres, A.; Boyer, C.; Falvard, A.; Ferdi, C.; Gay, P.; Guicheney, C.; Henrard, P.; Jousset, J.; Michel, B.; Monteil, S.; Montret, J.C.; Pallin, D.; Perret, P.; Podlyski, F.; Proriol, J.; Rosnet, P.; Rossignol, J.M.; Fearnley, T.; Hansen, J.D.; Hansen, J.R.; Hansen, P.H.; Nilsson, B.S.; Rensch, B.; Waananen, A.; Daskalakis, G.; Kyriakis, A.; Markou, C.; Simopoulou, E.; Vayaki, A.; Blondel, A.; Brient, J.C.; Machefert, F.; Rouge, A.; Rumpf, M.; Valassi, A.; Videau, H.; Focardi, E.; Parrini, G.; Zachariadou, K.; Cavanaugh, R.; Corden, M.; Georgiopoulos, C.; Huehn, T.; Jaffe, D.E.; Antonelli, A.; Bencivenni, G.; Bologna, G.; Bossi, F.; Campana, P.; Capon, G.; Casper, D.; Chiarella, V.; Felici, G.; Laurelli, P.; Mannocchi, G.; Murtas, F.; Murtas, G.P.; Passalacqua, L.; Pepe-Altarelli, M.; Curtis, L.; Dorris, S.J.; Halley, A.W.; Knowles, I.G.; Lynch, J.G.; O'Shea, V.; Raine, C.; Scarr, J.M.; Smith, K.; Teixeira-Dias, P.; Thompson, A.S.; Thomson, Evelyn J.; Thomson, F.; Turnbull, R.M.; Geweniger, C.; Graefe, G.; Hanke, P.; Hansper, G.; Hepp, V.; Kluge, E.E.; Putzer, A.; Schmidt, M.; Sommer, J.; Tittel, K.; Werner, S.; Wunsch, M.; Beuselinck, R.; Binnie, D.M.; Cameron, W.; Dornan, P.J.; Girone, M.; Goodsir, S.; Martin, E.B.; Morawitz, P.; Moutoussi, A.; Nash, J.; Sedgbeer, J.K.; Stacey, A.M.; Williams, M.D.; Girtler, P.; Kuhn, D.; Rudolph, G.; Betteridge, A.P.; Bowdery, C.K.; Colrain, P.; Crawford, G.; Finch, A.J.; Foster, F.; Hughes, G.; Jones, R.W.; Sloan, T.; Whelan, E.P.; Williams, M.I.; Hoffmann, C.; Jakobs, K.; Kleinknecht, K.; Quast, G.; Renk, B.; Rohne, E.; Sander, H.G.; van Gemmeren, P.; Zeitnitz, C.; Aubert, J.J.; Benchouk, C.; Bonissent, A.; Bujosa, G.; Calvet, D.; Carr, J.; Coyle, P.; Diaconu, C.; Konstantinidis, N.; Leroy, O.; Motsch, F.; Payre, P.; Rousseau, D.; Talby, M.; Sadouki, A.; Thulasidas, M.; Tilquin, A.; Trabelsi, K.; Aleppo, M.; Ragusa, F.; Berlich, R.; Blum, W.; Buescher, Volker; Dietl, H.; Ganis, G.; Gotzhein, C.; Kroha, H.; Lutjens, G.; Lutz, G.; Manner, W.; Moser, H.G.; Richter, Robert, 1; Rosado-Schlosser, A.; Schael, S.; Settles, R.; Seywerd, H.; St. Denis, Richard Dante; Stenzel, H.; Wiedenmann, W.; Wolf, G.; Boucrot, J.; Callot, O.; Chen, S.; Cordier, A.; Davier, M.; Duflot, L.; Grivaz, J.F.; Heusse, P.; Hocker, Andreas; Jacholkowska, A.; Jacquet, M.; Kim, D.W.; Le Diberder, F.; Lefrancois, J.; Lutz, A.M.; Nikolic, Irina; Schune, M.H.; Simion, S.; Tournefier, E.; Veillet, J.J.; Videau, I.; Zerwas, D.; Azzurri, P.; Bagliesi, Giuseppe; Batignani, G.; Bettarini, S.; Bozzi, C.; Calderini, G.; Carpinelli, M.; Ciocci, M.A.; Ciulli, V.; Dell'Orso, R.; Fantechi, R.; Ferrante, I.; Giassi, A.; Gregorio, A.; Ligabue, F.; Lusiani, A.; Marrocchesi, P.S.; Messineo, A.; Palla, F.; Sanguinetti, G.; Sciaba, A.; Spagnolo, P.; Steinberger, J.; Tenchini, R.; Tonelli, G.; Vannini, C.; Venturi, A.; Verdini, P.G.; Blair, G.A.; Bryant, L.M.; Chambers, J.T.; Gao, Y.; Green, M.G.; Medcalf, T.; Perrodo, P.; Strong, J.A.; von Wimmersperg-Toeller, J.H.; Botterill, D.R.; Clifft, R.W.; Edgecock, T.R.; Haywood, S.; Maley, P.; Norton, P.R.; Thompson, J.C.; Wright, A.E.; Bloch-Devaux, Brigitte; Colas, P.; Fabbro, B.; Kozanecki, W.; Lancon, E.; Lemaire, M.C.; Locci, E.; Perez, P.; Rander, J.; Renardy, J.F.; Rosowsky, A.; Roussarie, A.; Schuller, J.P.; Schwindling, J.; Trabelsi, A.; Vallage, B.; Black, S.N.; Dann, J.H.; Kim, H.Y.; Litke, A.M.; McNeil, M.A.; Taylor, G.; Booth, C.N.; Boswell, R.; Brew, C.A.J.; Cartwright, S.; Combley, F.; Kelly, M.S.; Lehto, M.; Newton, W.M.; Reeve, J.; Thompson, L.F.; Affholderbach, K.; Boehrer, Armin; Brandt, S.; Cowan, G.; Foss, J.; Grupen, C.; Saraiva, P.; Smolik, L.; Stephan, F.; Apollonio, M.; Bosisio, L.; Della Marina, R.; Giannini, G.; Gobbo, B.; Musolino, G.; Putz, J.; Rothberg, J.; Wasserbaech, S.; Williams, R.W.; Armstrong, S.R.; Charles, E.; Elmer, P.; Ferguson, D.P.S.; Gonzalez, S.; Greening, T.C.; Hayes, O.J.; Hu, H.; Jin, S.; McNamara, P.A., III; Nachtman, J.M.; Nielsen, J.; Orejudos, W.; Pan, Y.B.; Saadi, Y.; Scott, I.J.; Walsh, J.; Wu, S.L.; Wu, X.; Yamartino, J.M.; Zobernig, G.

    1997-01-01

    A search for pair-production of long-lived, heavy, singly-charged particles has been performed with data collected by the ALEPH detector at a centre-of-mass energy of 172 GeV. Data at \\sqrt{s} = 161, 136, and 130 GeV are also included to improve the sensitivity to lower masses. No candidate is found in the data. A model-independent 95 % confidence level upper limit on the production cross section at 172 GeV of 0.2-0.4 pb is derived for masses between 45 and 86 GeV/c^2. This cross section limit implies, assuming the MSSM, a lower limit of 67 (69) GeV/c^2 on the mass of right- (left-) handed long-lived scalar taus or scalar muons and of 86 GeV/c^2 on the mass of long-lived charginos.

  5. Search for pair-production of long-lived heavy charged particles in e+e- annihilation

    Science.gov (United States)

    Barate, R.; Buskulic, D.; Decamp, D.; Ghez, P.; Goy, C.; Lees, J.-P.; Lucotte, A.; Minard, M.-N.; Nief, J.-Y.; Pietrzyk, B.; Casado, M. P.; Chmeissani, M.; Comas, P.; Crespo, J. M.; Delfino, M.; Fernandez, E.; Fernandez-Bosman, M.; Garrido, Ll.; Juste, A.; Martinez, M.; Miquel, R.; Mir, Ll. M.; Orteu, S.; Padilla, C.; Park, I. C.; Pascual, A.; Perlas, J. A.; Riu, I.; Sanchez, F.; Teubert, F.; Colaleo, A.; Creanza, D.; de Palma, M.; Gelao, G.; Iaselli, G.; Maggi, G.; Maggi, M.; Marinelli, N.; Nuzzo, S.; Ranieri, A.; Raso, G.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Tricomi, A.; Zito, G.; Huang, X.; Lin, J.; Ouyang, Q.; Wang, T.; Xie, Y.; Xu, R.; Xue, S.; Zhang, J.; Zhang, L.; Zhao, W.; Abbaneo, D.; Alemany, R.; Bazarko, A. O.; Becker, U.; Bright-Thomas, P.; Cattaneo, M.; Cerutti, F.; Dissertori, G.; Drevermann, H.; Forty, R. W.; Frank, M.; Hagelberg, R.; Hansen, J. B.; Harvey, J.; Janot, P.; Jost, B.; Kneringer, E.; Knobloch, J.; Lehraus, I.; Lutters, G.; Mato, P.; Minten, A.; Moneta, L.; Pacheco, A.; Pusztaszeri, J.-F.; Ranjard, F.; Rizzo, G.; Rolandi, L.; Schlatter, D.; Schmitt, M.; Schneider, O.; Tejessy, W.; Tomalin, I. R.; Wachsmuth, H.; Wagner, A.; Ajaltouni, Z.; Barrès, A.; Boyer, C.; Falvard, A.; Ferdi, C.; Gay, P.; Guicheney, C.; Henrard, P.; Jousset, J.; Michel, B.; Monteil, S.; Montret, J.-C.; Pallin, D.; Perret, P.; Podlyski, F.; Proriol, J.; Rosnet, P.; Rossignol, J.-M.; Fearnley, T.; Hansen, J. D.; Hansen, J. R.; Hansen, P. H.; Nilsson, B. S.; Rensch, B.; Wäänänen, A.; Daskalakis, G.; Kyriakis, A.; Markou, C.; Simopoulou, E.; Vayaki, A.; Blondel, A.; Brient, J. C.; Machefert, F.; Rougé, A.; Rumpf, M.; Valassi, A.; Videau, H.; Focardi, E.; Parrini, G.; Zachariadou, K.; Cavanaugh, R.; Corden, M.; Georgiopoulos, C.; Huehn, T.; Jaffe, D. E.; Antonelli, A.; Bencivenni, G.; Bologna, G.; Bossi, F.; Campana, P.; Capon, G.; Casper, D.; Chiarella, V.; Felici, G.; Laurelli, P.; Mannocchi, G.; Murtas, F.; Murtas, G. P.; Passalacqua, L.; Pepe-Altarelli, M.; Curtis, L.; Dorris, S. J.; Halley, A. W.; Knowles, I. G.; Lynch, J. G.; O'Shea, V.; Raine, C.; Scarr, J. M.; Smith, K.; Teixeira-Dias, P.; Thompson, A. S.; Thomson, E.; Thomson, F.; Turnbull, R. M.; Geweniger, C.; Graefe, G.; Hanke, P.; Hansper, G.; Hepp, V.; Kluge, E. E.; Putzer, A.; Schmidt, M.; Sommer, J.; Tittel, K.; Werner, S.; Wunsch, M.; Beuselinck, R.; Binnie, D. M.; Cameron, W.; Dornan, P. J.; Girone, M.; Goodsir, S.; Martin, E. B.; Morawitz, P.; Moutoussi, A.; Nash, J.; Sedgbeer, J. K.; Stacey, A. M.; Williams, M. D.; Girtler, P.; Kuhn, D.; Rudolph, G.; Betteridge, A. P.; Bowdery, C. K.; Colrain, P.; Crawford, G.; Finch, A. J.; Foster, F.; Hughes, G.; Jones, R. W.; Sloan, T.; Whelan, E. P.; Williams, M. I.; Hoffmann, C.; Jakobs, K.; Kleinknecht, K.; Quast, G.; Renk, B.; Rohne, E.; Sander, H.-G.; van Gemmeren, P.; Zeitnitz, C.; Aubert, J. J.; Benchouk, C.; Bonissent, A.; Bujosa, G.; Calvet, D.; Carr, J.; Coyle, P.; Diaconu, C.; Konstantinidis, N.; Leroy, O.; Motsch, F.; Payre, P.; Rousseau, D.; Talby, M.; Sadouki, A.; Thulasidas, M.; Tilquin, A.; Trabelsi, K.; Aleppo, M.; Ragusa, F.; Berlich, R.; Blum, W.; Büscher, V.; Dietl, H.; Ganis, G.; Gotzhein, C.; Kroha, H.; Lütjens, G.; Lutz, G.; Männer, W.; Moser, H.-G.; Richter, R.; Rosado-Schlosser, A.; Schael, S.; Settles, R.; Seywerd, H.; St. Denis, R.; Stenzel, H.; Wiedenmann, W.; Wolf, G.; Boucrot, J.; Callot, O.; Chen, S.; Cordier, A.; Davier, M.; Duflot, L.; Grivaz, J.-F.; Heusse, Ph.; Höcker, A.; Jacholkowska, A.; Jacquet, M.; Kim, D. W.; Le Diberder, F.; Lefrançois, J.; Lutz, A.-M.; Nikolic, I.; Schune, M.-H.; Simion, S.; Tournefier, E.; Veillet, J.-J.; Videau, I.; Zerwas, D.; Azzurri, P.; Bagliesi, G.; Batignani, G.; Bettarini, S.; Bozzi, C.; Calderini, G.; Carpinelli, M.; Ciocci, M. A.; Ciulli, V.; dell'Orso, R.; Fantechi, R.; Ferrante, I.; Giassi, A.; Gregorio, A.; Ligabue, F.; Lusiani, A.; Marrocchesi, P. S.; Messineo, A.; Palla, F.; Sanguinetti, G.; Sciabà, A.; Spagnolo, P.; Steinberger, J.; Tenchini, R.; Tonelli, G.; Vannini, C.; Venturi, A.; Verdini, P. G.; Blair, G. A.; Bryant, L. M.; Chambers, J. T.; Gao, Y.; Green, M. G.; Medcalf, T.; Perrodo, P.; Strong, J. A.; von Wimmersperg-Toeller, J. H.; Botterill, D. R.; Clifft, R. W.; Edgecock, T. R.; Haywood, S.; Maley, P.; Norton, P. R.; Thompson, J. C.; Wright, A. E.; Bloch-Devaux, B.; Colas, P.; Fabbro, B.; Kozanecki, W.; Lançon, E.; Lemaire, M. C.; Locci, E.; Perez, P.; Rander, J.; Renardy, J.-F.; Rosowsky, A.; Roussarie, A.; Schuller, J.-P.; Schwindling, J.; Trabelsi, A.; Vallage, B.; Black, S. N.; Dann, J. H.; Kim, H. Y.; Litke, A. M.; McNeil, M. A.; Taylor, G.; Booth, C. N.; Boswell, R.; Brew, C. A. J.; Cartwright, S.; Combley, F.; Kelly, M. S.; Lehto, M.; Newton, W. M.; Reeve, J.; Thompson, L. F.; Affholderbach, K.; Böhrer, A.; Brandt, S.; Cowan, G.; Foss, J.; Grupen, C.; Saraiva, P.; Smolik, L.; Stephan, F.; Apollonio, M.; Bosisio, L.; della Marina, R.; Giannini, G.; Gobbo, B.; Musolino, G.; Putz, J.; Rothberg, J.; Wasserbaech, S.; Williams, R. W.; Armstrong, S. R.; Charles, E.; Elmer, P.; Ferguson, D. P. S.; González, S.; Greening, T. C.; Hayes, O. J.; Hu, H.; Jin, S.; McNamara, P. A.; Nachtman, J. M.; Nielsen, J.; Orejudos, W.; Pan, Y. B.; Saadi, Y.; Scott, I. J.; Walsh, J.; Sau, Lan Wu; Wu, X.; Yamartino, J. M.; Zobernig, G.

    1997-02-01

    A search for pair-production of long-lived, heavy, singly-charged particles has been performed with data collected by the ALEPH detector at a centre-of-mass energy of 172 GeV. Data at √s = 161, 136, and 130 GeV are also included to improve the sensitivity to lower masses. No candidate is found in the data. A model-independent 95% confidence level upper limit on the production cross section at 172 GeV of 0.2-0.4 pb is derived for masses between 45 and 86 GeV/c2. This cross section limit implies, assuming the MSSM, a lower limit of 67 (69) GeV/c2 on the mass of might- (left-) handed long-lived scalar taus or scalar muons and of 86 GeV/c2 on the mass of long-lived charginos.

  6. Charged particle detector

    International Nuclear Information System (INIS)

    Hagen, R.D.

    1975-01-01

    A device for detecting the emission of charged particles from a specimen is described. The specimen is placed within an accumulator means which statically accumulates any charged particles emitted from the specimen. The accumulator means is pivotally positioned between a first capacitor plate having a positive electrical charge and a second capacitor plate having a negative electrical charge. The accumulator means is attracted to one capacitor plate and repelled from the other capacitor plate by an amount proportional to the amount and intensity of charged particles emitted by the specimen. (auth)

  7. Search for metastable heavy charged particles with large ionisation energy loss in $pp$ collisions at $\\sqrt{s}$ = 8 TeV using the ATLAS experiment

    CERN Document Server

    Aad, Georges; Abdallah, Jalal; Abdinov, Ovsat; Aben, Rosemarie; Abolins, Maris; AbouZeid, Ossama; Abramowicz, Halina; Abreu, Henso; Abreu, Ricardo; Abulaiti, Yiming; Acharya, Bobby Samir; Adamczyk, Leszek; Adams, David; Adelman, Jahred; Adomeit, Stefanie; Adye, Tim; Affolder, Tony; Agatonovic-Jovin, Tatjana; Agricola, Johannes; Aguilar-Saavedra, Juan Antonio; Ahlen, Steven; Ahmadov, Faig; Aielli, Giulio; Akerstedt, Henrik; Åkesson, Torsten Paul Ake; Akimov, Andrei; Alberghi, Gian Luigi; Albert, Justin; Albrand, Solveig; Alconada Verzini, Maria Josefina; Aleksa, Martin; Aleksandrov, Igor; Alexa, Calin; Alexander, Gideon; Alexopoulos, Theodoros; Alhroob, Muhammad; Alimonti, Gianluca; Alio, Lion; Alison, John; Alkire, Steven Patrick; Allbrooke, Benedict; Allport, Phillip; Aloisio, Alberto; Alonso, Alejandro; Alonso, Francisco; Alpigiani, Cristiano; Altheimer, Andrew David; Alvarez Gonzalez, Barbara; Άlvarez Piqueras, Damián; Alviggi, Mariagrazia; Amadio, Brian Thomas; Amako, Katsuya; Amaral Coutinho, Yara; Amelung, Christoph; Amidei, Dante; Amor Dos Santos, Susana Patricia; Amorim, Antonio; Amoroso, Simone; Amram, Nir; Amundsen, Glenn; Anastopoulos, Christos; Ancu, Lucian Stefan; Andari, Nansi; Andeen, Timothy; Anders, Christoph Falk; Anders, Gabriel; Anders, John Kenneth; Anderson, Kelby; Andreazza, Attilio; Andrei, George Victor; Angelidakis, Stylianos; Angelozzi, Ivan; Anger, Philipp; Angerami, Aaron; Anghinolfi, Francis; Anisenkov, Alexey; Anjos, Nuno; Annovi, Alberto; Antonelli, Mario; Antonov, Alexey; Antos, Jaroslav; Anulli, Fabio; Aoki, Masato; Aperio Bella, Ludovica; Arabidze, Giorgi; Arai, Yasuo; Araque, Juan Pedro; Arce, Ayana; Arduh, Francisco Anuar; Arguin, Jean-Francois; Argyropoulos, Spyridon; Arik, Metin; Armbruster, Aaron James; Arnaez, Olivier; Arnal, Vanessa; Arnold, Hannah; Arratia, Miguel; Arslan, Ozan; Artamonov, Andrei; Artoni, Giacomo; Asai, Shoji; Asbah, Nedaa; Ashkenazi, Adi; Åsman, Barbro; Asquith, Lily; Assamagan, Ketevi; Astalos, Robert; Atkinson, Markus; Atlay, Naim Bora; Augsten, Kamil; Aurousseau, Mathieu; Avolio, Giuseppe; Axen, Bradley; Ayoub, Mohamad Kassem; Azuelos, Georges; Baak, Max; Baas, Alessandra; Baca, Matthew John; Bacci, Cesare; Bachacou, Henri; Bachas, Konstantinos; Backes, Moritz; Backhaus, Malte; Bagiacchi, Paolo; Bagnaia, Paolo; Bai, Yu; Bain, Travis; Baines, John; Baker, Oliver Keith; Baldin, Evgenii; Balek, Petr; Balestri, Thomas; Balli, Fabrice; Banas, Elzbieta; Banerjee, Swagato; Bannoura, Arwa A E; Bansil, Hardeep Singh; Barak, Liron; Barberio, Elisabetta Luigia; Barberis, Dario; Barbero, Marlon; Barillari, Teresa; Barisonzi, Marcello; Barklow, Timothy; Barlow, Nick; Barnes, Sarah Louise; Barnett, Bruce; Barnett, Michael; Barnovska, Zuzana; Baroncelli, Antonio; Barone, Gaetano; Barr, Alan; Barreiro, Fernando; Barreiro Guimarães da Costa, João; Bartoldus, Rainer; Barton, Adam Edward; Bartos, Pavol; Basalaev, Artem; Bassalat, Ahmed; Basye, Austin; Bates, Richard; Batista, Santiago Juan; Batley, Richard; Battaglia, Marco; Bauce, Matteo; Bauer, Florian; Bawa, Harinder Singh; Beacham, James Baker; Beattie, Michael David; Beau, Tristan; Beauchemin, Pierre-Hugues; Beccherle, Roberto; Bechtle, Philip; Beck, Hans Peter; Becker, Anne Kathrin; Becker, Maurice; Becker, Sebastian; Beckingham, Matthew; Becot, Cyril; Beddall, Andrew; Beddall, Ayda; Bednyakov, Vadim; Bee, Christopher; Beemster, Lars; Beermann, Thomas; Begel, Michael; Behr, Janna Katharina; Belanger-Champagne, Camille; Bell, William; Bella, Gideon; Bellagamba, Lorenzo; Bellerive, Alain; Bellomo, Massimiliano; Belotskiy, Konstantin; Beltramello, Olga; Benary, Odette; Benchekroun, Driss; Bender, Michael; Bendtz, Katarina; Benekos, Nektarios; Benhammou, Yan; Benhar Noccioli, Eleonora; Benitez Garcia, Jorge-Armando; Benjamin, Douglas; Bensinger, James; Bentvelsen, Stan; Beresford, Lydia; Beretta, Matteo; Berge, David; Bergeaas Kuutmann, Elin; Berger, Nicolas; Berghaus, Frank; Beringer, Jürg; Bernard, Clare; Bernard, Nathan Rogers; Bernius, Catrin; Bernlochner, Florian Urs; Berry, Tracey; Berta, Peter; Bertella, Claudia; Bertoli, Gabriele; Bertolucci, Federico; Bertsche, Carolyn; Bertsche, David; Besana, Maria Ilaria; Besjes, Geert-Jan; Bessidskaia Bylund, Olga; Bessner, Martin Florian; Besson, Nathalie; Betancourt, Christopher; Bethke, Siegfried; Bevan, Adrian John; Bhimji, Wahid; Bianchi, Riccardo-Maria; Bianchini, Louis; Bianco, Michele; Biebel, Otmar; Biedermann, Dustin; Bieniek, Stephen Paul; Biglietti, Michela; Bilbao De Mendizabal, Javier; Bilokon, Halina; Bindi, Marcello; Binet, Sebastien; Bingul, Ahmet; Bini, Cesare; Biondi, Silvia; Black, Curtis; Black, James; Black, Kevin; Blackburn, Daniel; Blair, Robert; Blanchard, Jean-Baptiste; Blanco, Jacobo Ezequiel; Blazek, Tomas; Bloch, Ingo; Blocker, Craig; Blum, Walter; Blumenschein, Ulrike; Bobbink, Gerjan; Bobrovnikov, Victor; Bocchetta, Simona Serena; Bocci, Andrea; Bock, Christopher; Boehler, Michael; Bogaerts, Joannes Andreas; Bogavac, Danijela; Bogdanchikov, Alexander; Bohm, Christian; Boisvert, Veronique; Bold, Tomasz; Boldea, Venera; Boldyrev, Alexey; Bomben, Marco; Bona, Marcella; Boonekamp, Maarten; Borisov, Anatoly; Borissov, Guennadi; Borroni, Sara; Bortfeldt, Jonathan; Bortolotto, Valerio; Bos, Kors; Boscherini, Davide; Bosman, Martine; Boudreau, Joseph; Bouffard, Julian; Bouhova-Thacker, Evelina Vassileva; Boumediene, Djamel Eddine; Bourdarios, Claire; Bousson, Nicolas; Boveia, Antonio; Boyd, James; Boyko, Igor; Bozic, Ivan; Bracinik, Juraj; Brandt, Andrew; Brandt, Gerhard; Brandt, Oleg; Bratzler, Uwe; Brau, Benjamin; Brau, James; Braun, Helmut; Brazzale, Simone Federico; Breaden Madden, William Dmitri; Brendlinger, Kurt; Brennan, Amelia Jean; Brenner, Lydia; Brenner, Richard; Bressler, Shikma; Bristow, Kieran; Bristow, Timothy Michael; Britton, Dave; Britzger, Daniel; Brochu, Frederic; Brock, Ian; Brock, Raymond; Bronner, Johanna; Brooijmans, Gustaaf; Brooks, Timothy; Brooks, William; Brosamer, Jacquelyn; Brost, Elizabeth; Brown, Jonathan; Bruckman de Renstrom, Pawel; Bruncko, Dusan; Bruneliere, Renaud; Bruni, Alessia; Bruni, Graziano; Bruschi, Marco; Bruscino, Nello; Bryngemark, Lene; Buanes, Trygve; Buat, Quentin; Buchholz, Peter; Buckley, Andrew; Buda, Stelian Ioan; Budagov, Ioulian; Buehrer, Felix; Bugge, Lars; Bugge, Magnar Kopangen; Bulekov, Oleg; Bullock, Daniel; Burckhart, Helfried; Burdin, Sergey; Burgard, Carsten Daniel; Burghgrave, Blake; Burke, Stephen; Burmeister, Ingo; Busato, Emmanuel; Büscher, Daniel; Büscher, Volker; Bussey, Peter; Butler, John; Butt, Aatif Imtiaz; Buttar, Craig; Butterworth, Jonathan; Butti, Pierfrancesco; Buttinger, William; Buzatu, Adrian; Buzykaev, Aleksey; Cabrera Urbán, Susana; Caforio, Davide; Cairo, Valentina; Cakir, Orhan; Calace, Noemi; Calafiura, Paolo; Calandri, Alessandro; Calderini, Giovanni; Calfayan, Philippe; Caloba, Luiz; Calvet, David; Calvet, Samuel; Camacho Toro, Reina; Camarda, Stefano; Camarri, Paolo; Cameron, David; Caminal Armadans, Roger; Campana, Simone; Campanelli, Mario; Campoverde, Angel; Canale, Vincenzo; Canepa, Anadi; Cano Bret, Marc; Cantero, Josu; Cantrill, Robert; Cao, Tingting; Capeans Garrido, Maria Del Mar; Caprini, Irinel; Caprini, Mihai; Capua, Marcella; Caputo, Regina; Cardarelli, Roberto; Cardillo, Fabio; Carli, Tancredi; Carlino, Gianpaolo; Carminati, Leonardo; Caron, Sascha; Carquin, Edson; Carrillo-Montoya, German D; Carter, Janet; Carvalho, João; Casadei, Diego; Casado, Maria Pilar; Casolino, Mirkoantonio; Castaneda-Miranda, Elizabeth; Castelli, Angelantonio; Castillo Gimenez, Victoria; Castro, Nuno Filipe; Catastini, Pierluigi; Catinaccio, Andrea; Catmore, James; Cattai, Ariella; Caudron, Julien; Cavaliere, Viviana; Cavalli, Donatella; Cavalli-Sforza, Matteo; Cavasinni, Vincenzo; Ceradini, Filippo; Cerio, Benjamin; Cerny, Karel; Santiago Cerqueira, Augusto; Cerri, Alessandro; Cerrito, Lucio; Cerutti, Fabio; Cerv, Matevz; Cervelli, Alberto; Cetin, Serkant Ali; Chafaq, Aziz; Chakraborty, Dhiman; Chalupkova, Ina; Chang, Philip; Chapman, John Derek; Charlton, Dave; Chau, Chav Chhiv; Chavez Barajas, Carlos Alberto; Cheatham, Susan; Chegwidden, Andrew; Chekanov, Sergei; Chekulaev, Sergey; Chelkov, Gueorgui; Chelstowska, Magda Anna; Chen, Chunhui; Chen, Hucheng; Chen, Karen; Chen, Liming; Chen, Shenjian; Chen, Xin; Chen, Ye; Cheng, Hok Chuen; Cheng, Yangyang; Cheplakov, Alexander; Cheremushkina, Evgenia; Cherkaoui El Moursli, Rajaa; Chernyatin, Valeriy; Cheu, Elliott; Chevalier, Laurent; Chiarella, Vitaliano; Chiarelli, Giorgio; Childers, John Taylor; Chiodini, Gabriele; Chisholm, Andrew; Chislett, Rebecca Thalatta; Chitan, Adrian; Chizhov, Mihail; Choi, Kyungeon; Chouridou, Sofia; Chow, Bonnie Kar Bo; Christodoulou, Valentinos; Chromek-Burckhart, Doris; Chudoba, Jiri; Chuinard, Annabelle Julia; Chwastowski, Janusz; Chytka, Ladislav; Ciapetti, Guido; Ciftci, Abbas Kenan; Cinca, Diane; Cindro, Vladimir; Cioara, Irina Antonela; Ciocio, Alessandra; Citron, Zvi Hirsh; Ciubancan, Mihai; Clark, Allan G; Clark, Brian Lee; Clark, Philip James; Clarke, Robert; Cleland, Bill; Clement, Christophe; Coadou, Yann; Cobal, Marina; Coccaro, Andrea; Cochran, James H; Coffey, Laurel; Cogan, Joshua Godfrey; Colasurdo, Luca; Cole, Brian; Cole, Stephen; Colijn, Auke-Pieter; Collot, Johann; Colombo, Tommaso; Compostella, Gabriele; Conde Muiño, Patricia; Coniavitis, Elias; Connell, Simon Henry; Connelly, Ian; Consonni, Sofia Maria; Consorti, Valerio; Constantinescu, Serban; Conta, Claudio; Conti, Geraldine; Conventi, Francesco; Cooke, Mark; Cooper, Ben; Cooper-Sarkar, Amanda; Cornelissen, Thijs; Corradi, Massimo; Corriveau, Francois; Corso-Radu, Alina; Cortes-Gonzalez, Arely; Cortiana, Giorgio; Costa, Giuseppe; Costa, María José; Costanzo, Davide; Côté, David; Cottin, Giovanna; Cowan, Glen; Cox, Brian; Cranmer, Kyle; Cree, Graham; Crépé-Renaudin, Sabine; Crescioli, Francesco; Cribbs, Wayne Allen; Crispin Ortuzar, Mireia; Cristinziani, Markus; Croft, Vince; Crosetti, Giovanni; Cuhadar Donszelmann, Tulay; Cummings, Jane; Curatolo, Maria; Cuthbert, Cameron; Czirr, Hendrik; Czodrowski, Patrick; D'Auria, Saverio; D'Onofrio, Monica; Da Cunha Sargedas De Sousa, Mario Jose; Da Via, Cinzia; Dabrowski, Wladyslaw; Dafinca, Alexandru; Dai, Tiesheng; Dale, Orjan; Dallaire, Frederick; Dallapiccola, Carlo; Dam, Mogens; Dandoy, Jeffrey Rogers; Dang, Nguyen Phuong; Daniells, Andrew Christopher; Danninger, Matthias; Dano Hoffmann, Maria; Dao, Valerio; Darbo, Giovanni; Darmora, Smita; Dassoulas, James; Dattagupta, Aparajita; Davey, Will; David, Claire; Davidek, Tomas; Davies, Eleanor; Davies, Merlin; Davison, Peter; Davygora, Yuriy; Dawe, Edmund; Dawson, Ian; Daya-Ishmukhametova, Rozmin; De, Kaushik; de Asmundis, Riccardo; De Benedetti, Abraham; De Castro, Stefano; De Cecco, Sandro; De Groot, Nicolo; de Jong, Paul; De la Torre, Hector; De Lorenzi, Francesco; De Nooij, Lucie; De Pedis, Daniele; De Salvo, Alessandro; De Sanctis, Umberto; De Santo, Antonella; De Vivie De Regie, Jean-Baptiste; Dearnaley, William James; Debbe, Ramiro; Debenedetti, Chiara; Dedovich, Dmitri; Deigaard, Ingrid; Del Peso, Jose; Del Prete, Tarcisio; Delgove, David; Deliot, Frederic; Delitzsch, Chris Malena; Deliyergiyev, Maksym; Dell'Acqua, Andrea; Dell'Asta, Lidia; Dell'Orso, Mauro; Della Pietra, Massimo; della Volpe, Domenico; Delmastro, Marco; Delsart, Pierre-Antoine; Deluca, Carolina; DeMarco, David; Demers, Sarah; Demichev, Mikhail; Demilly, Aurelien; Denisov, Sergey; Derendarz, Dominik; Derkaoui, Jamal Eddine; Derue, Frederic; Dervan, Paul; Desch, Klaus Kurt; Deterre, Cecile; Deviveiros, Pier-Olivier; Dewhurst, Alastair; Dhaliwal, Saminder; Di Ciaccio, Anna; Di Ciaccio, Lucia; Di Domenico, Antonio; Di Donato, Camilla; Di Girolamo, Alessandro; Di Girolamo, Beniamino; Di Mattia, Alessandro; Di Micco, Biagio; Di Nardo, Roberto; Di Simone, Andrea; Di Sipio, Riccardo; Di Valentino, David; Diaconu, Cristinel; Diamond, Miriam; Dias, Flavia; Diaz, Marco Aurelio; Diehl, Edward; Dietrich, Janet; Diglio, Sara; Dimitrievska, Aleksandra; Dingfelder, Jochen; Dita, Petre; Dita, Sanda; Dittus, Fridolin; Djama, Fares; Djobava, Tamar; Djuvsland, Julia Isabell; Barros do Vale, Maria Aline; Dobos, Daniel; Dobre, Monica; Doglioni, Caterina; Dohmae, Takeshi; Dolejsi, Jiri; Dolezal, Zdenek; Dolgoshein, Boris; Donadelli, Marisilvia; Donati, Simone; Dondero, Paolo; Donini, Julien; Dopke, Jens; Doria, Alessandra; Dova, Maria-Teresa; Doyle, Tony; Drechsler, Eric; Dris, Manolis; Dubreuil, Emmanuelle; Duchovni, Ehud; Duckeck, Guenter; Ducu, Otilia Anamaria; Duda, Dominik; Dudarev, Alexey; Duflot, Laurent; Duguid, Liam; Dührssen, Michael; Dunford, Monica; Duran Yildiz, Hatice; Düren, Michael; Durglishvili, Archil; Duschinger, Dirk; Dyndal, Mateusz; Eckardt, Christoph; Ecker, Katharina Maria; Edgar, Ryan Christopher; Edson, William; Edwards, Nicholas Charles; Ehrenfeld, Wolfgang; Eifert, Till; Eigen, Gerald; Einsweiler, Kevin; Ekelof, Tord; El Kacimi, Mohamed; Ellert, Mattias; Elles, Sabine; Ellinghaus, Frank; Elliot, Alison; Ellis, Nicolas; Elmsheuser, Johannes; Elsing, Markus; Emeliyanov, Dmitry; Enari, Yuji; Endner, Oliver Chris; Endo, Masaki; Erdmann, Johannes; Ereditato, Antonio; Ernis, Gunar; Ernst, Jesse; Ernst, Michael; Errede, Steven; Ertel, Eugen; Escalier, Marc; Esch, Hendrik; Escobar, Carlos; Esposito, Bellisario; Etienvre, Anne-Isabelle; Etzion, Erez; Evans, Hal; Ezhilov, Alexey; Fabbri, Laura; Facini, Gabriel; Fakhrutdinov, Rinat; Falciano, Speranza; Falla, Rebecca Jane; Faltova, Jana; Fang, Yaquan; Fanti, Marcello; Farbin, Amir; Farilla, Addolorata; Farooque, Trisha; Farrell, Steven; Farrington, Sinead; Farthouat, Philippe; Fassi, Farida; Fassnacht, Patrick; Fassouliotis, Dimitrios; Faucci Giannelli, Michele; Favareto, Andrea; Fayard, Louis; Federic, Pavol; Fedin, Oleg; Fedorko, Wojciech; Feigl, Simon; Feligioni, Lorenzo; Feng, Cunfeng; Feng, Eric; Feng, Haolu; Fenyuk, Alexander; Feremenga, Last; Fernandez Martinez, Patricia; Fernandez Perez, Sonia; Ferrando, James; Ferrari, Arnaud; Ferrari, Pamela; Ferrari, Roberto; Ferreira de Lima, Danilo Enoque; Ferrer, Antonio; Ferrere, Didier; Ferretti, Claudio; Ferretto Parodi, Andrea; Fiascaris, Maria; Fiedler, Frank; Filipčič, Andrej; Filipuzzi, Marco; Filthaut, Frank; Fincke-Keeler, Margret; Finelli, Kevin Daniel; Fiolhais, Miguel; Fiorini, Luca; Firan, Ana; Fischer, Adam; Fischer, Cora; Fischer, Julia; Fisher, Wade Cameron; Fitzgerald, Eric Andrew; Flaschel, Nils; Fleck, Ivor; Fleischmann, Philipp; Fleischmann, Sebastian; Fletcher, Gareth Thomas; Fletcher, Gregory; Fletcher, Rob Roy MacGregor; Flick, Tobias; Floderus, Anders; Flores Castillo, Luis; Flowerdew, Michael; Formica, Andrea; Forti, Alessandra; Fournier, Daniel; Fox, Harald; Fracchia, Silvia; Francavilla, Paolo; Franchini, Matteo; Francis, David; Franconi, Laura; Franklin, Melissa; Frate, Meghan; Fraternali, Marco; Freeborn, David; French, Sky; Friedrich, Felix; Froidevaux, Daniel; Frost, James; Fukunaga, Chikara; Fullana Torregrosa, Esteban; Fulsom, Bryan Gregory; Fusayasu, Takahiro; Fuster, Juan; Gabaldon, Carolina; Gabizon, Ofir; Gabrielli, Alessandro; Gabrielli, Andrea; Gach, Grzegorz; Gadatsch, Stefan; Gadomski, Szymon; Gagliardi, Guido; Gagnon, Pauline; Galea, Cristina; Galhardo, Bruno; Gallas, Elizabeth; Gallop, Bruce; Gallus, Petr; Galster, Gorm Aske Gram Krohn; Gan, KK; Gao, Jun; Gao, Yanyan; Gao, Yongsheng; Garay Walls, Francisca; Garberson, Ford; García, Carmen; García Navarro, José Enrique; Garcia-Sciveres, Maurice; Gardner, Robert; Garelli, Nicoletta; Garonne, Vincent; Gatti, Claudio; Gaudiello, Andrea; Gaudio, Gabriella; Gaur, Bakul; Gauthier, Lea; Gauzzi, Paolo; Gavrilenko, Igor; Gay, Colin; Gaycken, Goetz; Gazis, Evangelos; Ge, Peng; Gecse, Zoltan; Gee, Norman; Geerts, Daniël Alphonsus Adrianus; Geich-Gimbel, Christoph; Geisler, Manuel Patrice; Gemme, Claudia; Genest, Marie-Hélène; Gentile, Simonetta; George, Matthias; George, Simon; Gerbaudo, Davide; Gershon, Avi; Ghasemi, Sara; Ghazlane, Hamid; Giacobbe, Benedetto; Giagu, Stefano; Giangiobbe, Vincent; Giannetti, Paola; Gibbard, Bruce; Gibson, Stephen; Gilchriese, Murdock; Gillam, Thomas; Gillberg, Dag; Gilles, Geoffrey; Gingrich, Douglas; Giokaris, Nikos; Giordani, MarioPaolo; Giorgi, Filippo Maria; Giorgi, Francesco Michelangelo; Giraud, Pierre-Francois; Giromini, Paolo; Giugni, Danilo; Giuliani, Claudia; Giulini, Maddalena; Gjelsten, Børge Kile; Gkaitatzis, Stamatios; Gkialas, Ioannis; Gkougkousis, Evangelos Leonidas; Gladilin, Leonid; Glasman, Claudia; Glatzer, Julian; Glaysher, Paul; Glazov, Alexandre; Goblirsch-Kolb, Maximilian; Goddard, Jack Robert; Godlewski, Jan; Goldfarb, Steven; Golling, Tobias; Golubkov, Dmitry; Gomes, Agostinho; Gonçalo, Ricardo; Goncalves Pinto Firmino Da Costa, Joao; Gonella, Laura; González de la Hoz, Santiago; Gonzalez Parra, Garoe; Gonzalez-Sevilla, Sergio; Goossens, Luc; Gorbounov, Petr Andreevich; Gordon, Howard; Gorelov, Igor; Gorini, Benedetto; Gorini, Edoardo; Gorišek, Andrej; Gornicki, Edward; Goshaw, Alfred; Gössling, Claus; Gostkin, Mikhail Ivanovitch; Goujdami, Driss; Goussiou, Anna; Govender, Nicolin; Gozani, Eitan; Grabas, Herve Marie Xavier; Graber, Lars; Grabowska-Bold, Iwona; Gradin, Per Olov Joakim; Grafström, Per; Grahn, Karl-Johan; Gramling, Johanna; Gramstad, Eirik; Grancagnolo, Sergio; Gratchev, Vadim; Gray, Heather; Graziani, Enrico; Greenwood, Zeno Dixon; Gregersen, Kristian; Gregor, Ingrid-Maria; Grenier, Philippe; Griffiths, Justin; Grillo, Alexander; Grimm, Kathryn; Grinstein, Sebastian; Gris, Philippe Luc Yves; Grivaz, Jean-Francois; Grohs, Johannes Philipp; Grohsjean, Alexander; Gross, Eilam; Grosse-Knetter, Joern; Grossi, Giulio Cornelio; Grout, Zara Jane; Guan, Liang; Guenther, Jaroslav; Guescini, Francesco; Guest, Daniel; Gueta, Orel; Guido, Elisa; Guillemin, Thibault; Guindon, Stefan; Gul, Umar; Gumpert, Christian; Guo, Jun; Guo, Yicheng; Gupta, Shaun; Gustavino, Giuliano; Gutierrez, Phillip; Gutierrez Ortiz, Nicolas Gilberto; Gutschow, Christian; Guyot, Claude; Gwenlan, Claire; Gwilliam, Carl; Haas, Andy; Haber, Carl; Hadavand, Haleh Khani; Haddad, Nacim; Haefner, Petra; Hageböck, Stephan; Hajduk, Zbigniew; Hakobyan, Hrachya; Haleem, Mahsana; Haley, Joseph; Hall, David; Halladjian, Garabed; Hallewell, Gregory David; Hamacher, Klaus; Hamal, Petr; Hamano, Kenji; Hamilton, Andrew; Hamity, Guillermo Nicolas; Hamnett, Phillip George; Han, Liang; Hanagaki, Kazunori; Hanawa, Keita; Hance, Michael; Hanke, Paul; Hanna, Remie; Hansen, Jørgen Beck; Hansen, Jorn Dines; Hansen, Maike Christina; Hansen, Peter Henrik; Hara, Kazuhiko; Hard, Andrew; Harenberg, Torsten; Hariri, Faten; Harkusha, Siarhei; Harrington, Robert; Harrison, Paul Fraser; Hartjes, Fred; Hasegawa, Makoto; Hasegawa, Satoshi; Hasegawa, Yoji; Hasib, A; Hassani, Samira; Haug, Sigve; Hauser, Reiner; Hauswald, Lorenz; Havranek, Miroslav; Hawkes, Christopher; Hawkings, Richard John; Hawkins, Anthony David; Hayashi, Takayasu; Hayden, Daniel; Hays, Chris; Hays, Jonathan Michael; Hayward, Helen; Haywood, Stephen; Head, Simon; Heck, Tobias; Hedberg, Vincent; Heelan, Louise; Heim, Sarah; Heim, Timon; Heinemann, Beate; Heinrich, Lukas; Hejbal, Jiri; Helary, Louis; Hellman, Sten; Hellmich, Dennis; Helsens, Clement; Henderson, James; Henderson, Robert; Heng, Yang; Hengler, Christopher; Henrichs, Anna; Henriques Correia, Ana Maria; Henrot-Versille, Sophie; Herbert, Geoffrey Henry; Hernández Jiménez, Yesenia; Herrberg-Schubert, Ruth; Herten, Gregor; Hertenberger, Ralf; Hervas, Luis; Hesketh, Gavin Grant; Hessey, Nigel; Hetherly, Jeffrey Wayne; Hickling, Robert; Higón-Rodriguez, Emilio; Hill, Ewan; Hill, John; Hiller, Karl Heinz; Hillier, Stephen; Hinchliffe, Ian; Hines, Elizabeth; Hinman, Rachel Reisner; Hirose, Minoru; Hirschbuehl, Dominic; Hobbs, John; Hod, Noam; Hodgkinson, Mark; Hodgson, Paul; Hoecker, Andreas; Hoeferkamp, Martin; Hoenig, Friedrich; Hohlfeld, Marc; Hohn, David; Holmes, Tova Ray; Homann, Michael; Hong, Tae Min; Hooft van Huysduynen, Loek; Hopkins, Walter; Horii, Yasuyuki; Horton, Arthur James; Hostachy, Jean-Yves; Hou, Suen; Hoummada, Abdeslam; Howard, Jacob; Howarth, James; Hrabovsky, Miroslav; Hristova, Ivana; Hrivnac, Julius; Hryn'ova, Tetiana; Hrynevich, Aliaksei; Hsu, Catherine; Hsu, Pai-hsien Jennifer; Hsu, Shih-Chieh; Hu, Diedi; Hu, Qipeng; Hu, Xueye; Huang, Yanping; Hubacek, Zdenek; Hubaut, Fabrice; Huegging, Fabian; Huffman, Todd Brian; Hughes, Emlyn; Hughes, Gareth; Huhtinen, Mika; Hülsing, Tobias Alexander; Huseynov, Nazim; Huston, Joey; Huth, John; Iacobucci, Giuseppe; Iakovidis, Georgios; Ibragimov, Iskander; Iconomidou-Fayard, Lydia; Ideal, Emma; Idrissi, Zineb; Iengo, Paolo; Igonkina, Olga; Iizawa, Tomoya; Ikegami, Yoichi; Ikematsu, Katsumasa; Ikeno, Masahiro; Ilchenko, Iurii; Iliadis, Dimitrios; Ilic, Nikolina; Ince, Tayfun; Introzzi, Gianluca; Ioannou, Pavlos; Iodice, Mauro; Iordanidou, Kalliopi; Ippolito, Valerio; Irles Quiles, Adrian; Isaksson, Charlie; Ishino, Masaya; Ishitsuka, Masaki; Ishmukhametov, Renat; Issever, Cigdem; Istin, Serhat; Iturbe Ponce, Julia Mariana; Iuppa, Roberto; Ivarsson, Jenny; Iwanski, Wieslaw; Iwasaki, Hiroyuki; Izen, Joseph; Izzo, Vincenzo; Jabbar, Samina; Jackson, Brett; Jackson, Matthew; Jackson, Paul; Jaekel, Martin; Jain, Vivek; Jakobs, Karl; Jakobsen, Sune; Jakoubek, Tomas; Jakubek, Jan; Jamin, David Olivier; Jana, Dilip; Jansen, Eric; Jansky, Roland; Janssen, Jens; Janus, Michel; Jarlskog, Göran; Javadov, Namig; Javůrek, Tomáš; Jeanty, Laura; Jejelava, Juansher; Jeng, Geng-yuan; Jennens, David; Jenni, Peter; Jentzsch, Jennifer; Jeske, Carl; Jézéquel, Stéphane; Ji, Haoshuang; Jia, Jiangyong; Jiang, Yi; Jiggins, Stephen; Jimenez Pena, Javier; Jin, Shan; Jinaru, Adam; Jinnouchi, Osamu; Joergensen, Morten Dam; Johansson, Per; Johns, Kenneth; Jon-And, Kerstin; Jones, Graham; Jones, Roger; Jones, Tim; Jongmanns, Jan; Jorge, Pedro; Joshi, Kiran Daniel; Jovicevic, Jelena; Ju, Xiangyang; Jung, Christian; Jussel, Patrick; Juste Rozas, Aurelio; Kaci, Mohammed; Kaczmarska, Anna; Kado, Marumi; Kagan, Harris; Kagan, Michael; Kahn, Sebastien Jonathan; Kajomovitz, Enrique; Kalderon, Charles William; Kama, Sami; Kamenshchikov, Andrey; Kanaya, Naoko; Kaneti, Steven; Kantserov, Vadim; Kanzaki, Junichi; Kaplan, Benjamin; Kaplan, Laser Seymour; Kapliy, Anton; Kar, Deepak; Karakostas, Konstantinos; Karamaoun, Andrew; Karastathis, Nikolaos; Kareem, Mohammad Jawad; Karnevskiy, Mikhail; Karpov, Sergey; Karpova, Zoya; Karthik, Krishnaiyengar; Kartvelishvili, Vakhtang; Karyukhin, Andrey; Kashif, Lashkar; Kass, Richard; Kastanas, Alex; Kataoka, Yousuke; Kato, Chikuma; Katre, Akshay; Katzy, Judith; Kawagoe, Kiyotomo; Kawamoto, Tatsuo; Kawamura, Gen; Kazama, Shingo; Kazanin, Vassili; Keeler, Richard; Kehoe, Robert; Keller, John; Kempster, Jacob Julian; Keoshkerian, Houry; Kepka, Oldrich; Kerševan, Borut Paul; Kersten, Susanne; Keyes, Robert; Khalil-zada, Farkhad; Khandanyan, Hovhannes; Khanov, Alexander; Kharlamov, Alexey; Khoo, Teng Jian; Khovanskiy, Valery; Khramov, Evgeniy; Khubua, Jemal; Kido, Shogo; Kim, Hee Yeun; Kim, Shinhong; Kim, Young-Kee; Kimura, Naoki; Kind, Oliver Maria; King, Barry; King, Matthew; King, Samuel Burton; Kirk, Julie; Kiryunin, Andrey; Kishimoto, Tomoe; Kisielewska, Danuta; Kiss, Florian; Kiuchi, Kenji; Kivernyk, Oleh; Kladiva, Eduard; Klein, Matthew Henry; Klein, Max; Klein, Uta; Kleinknecht, Konrad; Klimek, Pawel; Klimentov, Alexei; Klingenberg, Reiner; Klinger, Joel Alexander; Klioutchnikova, Tatiana; Kluge, Eike-Erik; Kluit, Peter; Kluth, Stefan; Knapik, Joanna; Kneringer, Emmerich; Knoops, Edith; Knue, Andrea; Kobayashi, Aine; Kobayashi, Dai; Kobayashi, Tomio; Kobel, Michael; Kocian, Martin; Kodys, Peter; Koffas, Thomas; Koffeman, Els; Kogan, Lucy Anne; Kohlmann, Simon; Kohout, Zdenek; Kohriki, Takashi; Koi, Tatsumi; Kolanoski, Hermann; Koletsou, Iro; Komar, Aston; Komori, Yuto; Kondo, Takahiko; Kondrashova, Nataliia; Köneke, Karsten; König, Adriaan; Kono, Takanori; Konoplich, Rostislav; Konstantinidis, Nikolaos; Kopeliansky, Revital; Koperny, Stefan; Köpke, Lutz; Kopp, Anna Katharina; Korcyl, Krzysztof; Kordas, Kostantinos; Korn, Andreas; Korol, Aleksandr; Korolkov, Ilya; Korolkova, Elena; Kortner, Oliver; Kortner, Sandra; Kosek, Tomas; Kostyukhin, Vadim; Kotov, Vladislav; Kotwal, Ashutosh; Kourkoumeli-Charalampidi, Athina; Kourkoumelis, Christine; Kouskoura, Vasiliki; Koutsman, Alex; Kowalewski, Robert Victor; Kowalski, Tadeusz; Kozanecki, Witold; Kozhin, Anatoly; Kramarenko, Viktor; Kramberger, Gregor; Krasnopevtsev, Dimitriy; Krasny, Mieczyslaw Witold; Krasznahorkay, Attila; Kraus, Jana; Kravchenko, Anton; Kreiss, Sven; Kretz, Moritz; Kretzschmar, Jan; Kreutzfeldt, Kristof; Krieger, Peter; Krizka, Karol; Kroeninger, Kevin; Kroha, Hubert; Kroll, Joe; Kroseberg, Juergen; Krstic, Jelena; Kruchonak, Uladzimir; Krüger, Hans; Krumnack, Nils; Kruse, Amanda; Kruse, Mark; Kruskal, Michael; Kubota, Takashi; Kucuk, Hilal; Kuday, Sinan; Kuehn, Susanne; Kugel, Andreas; Kuger, Fabian; Kuhl, Andrew; Kuhl, Thorsten; Kukhtin, Victor; Kulchitsky, Yuri; Kuleshov, Sergey; Kuna, Marine; Kunigo, Takuto; Kupco, Alexander; Kurashige, Hisaya; Kurochkin, Yurii; Kus, Vlastimil; Kuwertz, Emma Sian; Kuze, Masahiro; Kvita, Jiri; Kwan, Tony; Kyriazopoulos, Dimitrios; La Rosa, Alessandro; La Rosa Navarro, Jose Luis; La Rotonda, Laura; Lacasta, Carlos; Lacava, Francesco; Lacey, James; Lacker, Heiko; Lacour, Didier; Lacuesta, Vicente Ramón; Ladygin, Evgueni; Lafaye, Remi; Laforge, Bertrand; Lagouri, Theodota; Lai, Stanley; Lambourne, Luke; Lammers, Sabine; Lampen, Caleb; Lampl, Walter; Lançon, Eric; Landgraf, Ulrich; Landon, Murrough; Lang, Valerie Susanne; Lange, J örn Christian; Lankford, Andrew; Lanni, Francesco; Lantzsch, Kerstin; Lanza, Agostino; Laplace, Sandrine; Lapoire, Cecile; Laporte, Jean-Francois; Lari, Tommaso; Lasagni Manghi, Federico; Lassnig, Mario; Laurelli, Paolo; Lavrijsen, Wim; Law, Alexander; Laycock, Paul; Lazovich, Tomo; Le Dortz, Olivier; Le Guirriec, Emmanuel; Le Menedeu, Eve; LeBlanc, Matthew Edgar; LeCompte, Thomas; Ledroit-Guillon, Fabienne Agnes Marie; Lee, Claire Alexandra; Lee, Shih-Chang; Lee, Lawrence; Lefebvre, Guillaume; Lefebvre, Michel; Legger, Federica; Leggett, Charles; Lehan, Allan; Lehmann Miotto, Giovanna; Lei, Xiaowen; Leight, William Axel; Leisos, Antonios; Leister, Andrew Gerard; Leite, Marco Aurelio Lisboa; Leitner, Rupert; Lellouch, Daniel; Lemmer, Boris; Leney, Katharine; Lenz, Tatjana; Lenzi, Bruno; Leone, Robert; Leone, Sandra; Leonidopoulos, Christos; Leontsinis, Stefanos; Leroy, Claude; Lester, Christopher; Levchenko, Mikhail; Levêque, Jessica; Levin, Daniel; Levinson, Lorne; Levy, Mark; Lewis, Adrian; Leyko, Agnieszka; Leyton, Michael; Li, Bing; Li, Haifeng; Li, Ho Ling; Li, Lei; Li, Liang; Li, Shu; Li, Yichen; Liang, Zhijun; Liao, Hongbo; Liberti, Barbara; Liblong, Aaron; Lichard, Peter; Lie, Ki; Liebal, Jessica; Liebig, Wolfgang; Limbach, Christian; Limosani, Antonio; Lin, Simon; Lin, Tai-Hua; Linde, Frank; Lindquist, Brian Edward; Linnemann, James; Lipeles, Elliot; Lipniacka, Anna; Lisovyi, Mykhailo; Liss, Tony; Lissauer, David; Lister, Alison; Litke, Alan; Liu, Bo; Liu, Dong; Liu, Hao; Liu, Jian; Liu, Jianbei; Liu, Kun; Liu, Lulu; Liu, Miaoyuan; Liu, Minghui; Liu, Yanwen; Livan, Michele; Lleres, Annick; Llorente Merino, Javier; Lloyd, Stephen; Lo Sterzo, Francesco; Lobodzinska, Ewelina; Loch, Peter; Lockman, William; Loebinger, Fred; Loevschall-Jensen, Ask Emil; Loginov, Andrey; Lohse, Thomas; Lohwasser, Kristin; Lokajicek, Milos; Long, Brian Alexander; Long, Jonathan; Long, Robin Eamonn; Looper, Kristina Anne; Lopes, Lourenco; Lopez Mateos, David; Lopez Paredes, Brais; Lopez Paz, Ivan; Lorenz, Jeanette; Lorenzo Martinez, Narei; Losada, Marta; Loscutoff, Peter; Lösel, Philipp Jonathan; Lou, XinChou; Lounis, Abdenour; Love, Jeremy; Love, Peter; Lu, Nan; Lubatti, Henry; Luci, Claudio; Lucotte, Arnaud; Luehring, Frederick; Lukas, Wolfgang; Luminari, Lamberto; Lundberg, Olof; Lund-Jensen, Bengt; Lynn, David; Lysak, Roman; Lytken, Else; Ma, Hong; Ma, Lian Liang; Maccarrone, Giovanni; Macchiolo, Anna; Macdonald, Calum Michael; Maček, Boštjan; Machado Miguens, Joana; Macina, Daniela; Madaffari, Daniele; Madar, Romain; Maddocks, Harvey Jonathan; Mader, Wolfgang; Madsen, Alexander; Maeda, Junpei; Maeland, Steffen; Maeno, Tadashi; Maevskiy, Artem; Magradze, Erekle; Mahboubi, Kambiz; Mahlstedt, Joern; Maiani, Camilla; Maidantchik, Carmen; Maier, Andreas Alexander; Maier, Thomas; Maio, Amélia; Majewski, Stephanie; Makida, Yasuhiro; Makovec, Nikola; Malaescu, Bogdan; Malecki, Pawel; Maleev, Victor; Malek, Fairouz; Mallik, Usha; Malon, David; Malone, Caitlin; Maltezos, Stavros; Malyshev, Vladimir; Malyukov, Sergei; Mamuzic, Judita; Mancini, Giada; Mandelli, Beatrice; Mandelli, Luciano; Mandić, Igor; Mandrysch, Rocco; Maneira, José; Manfredini, Alessandro; Manhaes de Andrade Filho, Luciano; Manjarres Ramos, Joany; Mann, Alexander; Manousakis-Katsikakis, Arkadios; Mansoulie, Bruno; Mantifel, Rodger; Mantoani, Matteo; Mapelli, Livio; March, Luis; Marchiori, Giovanni; Marcisovsky, Michal; Marino, Christopher; Marjanovic, Marija; Marley, Daniel; Marroquim, Fernando; Marsden, Stephen Philip; Marshall, Zach; Marti, Lukas Fritz; Marti-Garcia, Salvador; Martin, Brian Thomas; Martin, Tim; Martin, Victoria Jane; Martin dit Latour, Bertrand; Martinez, Mario; Martin-Haugh, Stewart; Martoiu, Victor Sorin; Martyniuk, Alex; Marx, Marilyn; Marzano, Francesco; Marzin, Antoine; Masetti, Lucia; Mashimo, Tetsuro; Mashinistov, Ruslan; Masik, Jiri; Maslennikov, Alexey; Massa, Ignazio; Massa, Lorenzo; Massol, Nicolas; Mastrandrea, Paolo; Mastroberardino, Anna; Masubuchi, Tatsuya; Mättig, Peter; Mattmann, Johannes; Maurer, Julien; Maxfield, Stephen; Maximov, Dmitriy; Mazini, Rachid; Mazza, Simone Michele; Mazzaferro, Luca; Mc Goldrick, Garrin; Mc Kee, Shawn Patrick; McCarn, Allison; McCarthy, Robert; McCarthy, Tom; McCubbin, Norman; McFarlane, Kenneth; Mcfayden, Josh; Mchedlidze, Gvantsa; McMahon, Steve; McPherson, Robert; Medinnis, Michael; Meehan, Samuel; Mehlhase, Sascha; Mehta, Andrew; Meier, Karlheinz; Meineck, Christian; Meirose, Bernhard; Mellado Garcia, Bruce Rafael; Meloni, Federico; Mengarelli, Alberto; Menke, Sven; Meoni, Evelin; Mercurio, Kevin Michael; Mergelmeyer, Sebastian; Mermod, Philippe; Merola, Leonardo; Meroni, Chiara; Merritt, Frank; Messina, Andrea; Metcalfe, Jessica; Mete, Alaettin Serhan; Meyer, Carsten; Meyer, Christopher; Meyer, Jean-Pierre; Meyer, Jochen; Meyer Zu Theenhausen, Hanno; Middleton, Robin; Miglioranzi, Silvia; Mijović, Liza; Mikenberg, Giora; Mikestikova, Marcela; Mikuž, Marko; Milesi, Marco; Milic, Adriana; Miller, David; Mills, Corrinne; Milov, Alexander; Milstead, David; Minaenko, Andrey; Minami, Yuto; Minashvili, Irakli; Mincer, Allen; Mindur, Bartosz; Mineev, Mikhail; Ming, Yao; Mir, Lluisa-Maria; Mitani, Takashi; Mitrevski, Jovan; Mitsou, Vasiliki A; Miucci, Antonio; Miyagawa, Paul; Mjörnmark, Jan-Ulf; Moa, Torbjoern; Mochizuki, Kazuya; Mohapatra, Soumya; Mohr, Wolfgang; Molander, Simon; Moles-Valls, Regina; Mönig, Klaus; Monini, Caterina; Monk, James; Monnier, Emmanuel; Montejo Berlingen, Javier; Monticelli, Fernando; Monzani, Simone; Moore, Roger; Morange, Nicolas; Moreno, Deywis; Moreno Llácer, María; Morettini, Paolo; Morgenstern, Marcus; Mori, Daniel; Morii, Masahiro; Morinaga, Masahiro; Morisbak, Vanja; Moritz, Sebastian; Morley, Anthony Keith; Mornacchi, Giuseppe; Morris, John; Mortensen, Simon Stark; Morton, Alexander; Morvaj, Ljiljana; Mosidze, Maia; Moss, Josh; Motohashi, Kazuki; Mount, Richard; Mountricha, Eleni; Mouraviev, Sergei; Moyse, Edward; Muanza, Steve; Mudd, Richard; Mueller, Felix; Mueller, James; Mueller, Ralph Soeren Peter; Mueller, Thibaut; Muenstermann, Daniel; Mullen, Paul; Mullier, Geoffrey; Murillo Quijada, Javier Alberto; Murray, Bill; Musheghyan, Haykuhi; Musto, Elisa; Myagkov, Alexey; Myska, Miroslav; Nachman, Benjamin Philip; Nackenhorst, Olaf; Nadal, Jordi; Nagai, Koichi; Nagai, Ryo; Nagai, Yoshikazu; Nagano, Kunihiro; Nagarkar, Advait; Nagasaka, Yasushi; Nagata, Kazuki; Nagel, Martin; Nagy, Elemer; Nairz, Armin Michael; Nakahama, Yu; Nakamura, Koji; Nakamura, Tomoaki; Nakano, Itsuo; Namasivayam, Harisankar; Naranjo Garcia, Roger Felipe; Narayan, Rohin; Naumann, Thomas; Navarro, Gabriela; Nayyar, Ruchika; Neal, Homer; Nechaeva, Polina; Neep, Thomas James; Nef, Pascal Daniel; Negri, Andrea; Negrini, Matteo; Nektarijevic, Snezana; Nellist, Clara; Nelson, Andrew; Nemecek, Stanislav; Nemethy, Peter; Nepomuceno, Andre Asevedo; Nessi, Marzio; Neubauer, Mark; Neumann, Manuel; Neves, Ricardo; Nevski, Pavel; Newman, Paul; Nguyen, Duong Hai; Nickerson, Richard; Nicolaidou, Rosy; Nicquevert, Bertrand; Nielsen, Jason; Nikiforou, Nikiforos; Nikiforov, Andriy; Nikolaenko, Vladimir; Nikolic-Audit, Irena; Nikolopoulos, Konstantinos; Nilsen, Jon Kerr; Nilsson, Paul; Ninomiya, Yoichi; Nisati, Aleandro; Nisius, Richard; Nobe, Takuya; Nomachi, Masaharu; Nomidis, Ioannis; Nooney, Tamsin; Norberg, Scarlet; Nordberg, Markus; Novgorodova, Olga; Nowak, Sebastian; Nozaki, Mitsuaki; Nozka, Libor; Ntekas, Konstantinos; Nunes Hanninger, Guilherme; Nunnemann, Thomas; Nurse, Emily; Nuti, Francesco; O'Brien, Brendan Joseph; O'grady, Fionnbarr; O'Neil, Dugan; O'Shea, Val; Oakham, Gerald; Oberlack, Horst; Obermann, Theresa; Ocariz, Jose; Ochi, Atsuhiko; Ochoa, Ines; Ochoa-Ricoux, Juan Pedro; Oda, Susumu; Odaka, Shigeru; Ogren, Harold; Oh, Alexander; Oh, Seog; Ohm, Christian; Ohman, Henrik; Oide, Hideyuki; Okamura, Wataru; Okawa, Hideki; Okumura, Yasuyuki; Okuyama, Toyonobu; Olariu, Albert; Olivares Pino, Sebastian Andres; Oliveira Damazio, Denis; Oliver Garcia, Elena; Olszewski, Andrzej; Olszowska, Jolanta; Onofre, António; Onyisi, Peter; Oram, Christopher; Oreglia, Mark; Oren, Yona; Orestano, Domizia; Orlando, Nicola; Oropeza Barrera, Cristina; Orr, Robert; Osculati, Bianca; Ospanov, Rustem; Otero y Garzon, Gustavo; Otono, Hidetoshi; Ouchrif, Mohamed; Ouellette, Eric; Ould-Saada, Farid; Ouraou, Ahmimed; Oussoren, Koen Pieter; Ouyang, Qun; Ovcharova, Ana; Owen, Mark; Owen, Rhys Edward; Ozcan, Veysi Erkcan; Ozturk, Nurcan; Pachal, Katherine; Pacheco Pages, Andres; Padilla Aranda, Cristobal; Pagáčová, Martina; Pagan Griso, Simone; Paganis, Efstathios; Paige, Frank; Pais, Preema; Pajchel, Katarina; Palacino, Gabriel; Palestini, Sandro; Palka, Marek; Pallin, Dominique; Palma, Alberto; Pan, Yibin; Panagiotopoulou, Evgenia; Pandini, Carlo Enrico; Panduro Vazquez, William; Pani, Priscilla; Panitkin, Sergey; Pantea, Dan; Paolozzi, Lorenzo; Papadopoulou, Theodora; Papageorgiou, Konstantinos; Paramonov, Alexander; Paredes Hernandez, Daniela; Parker, Michael Andrew; Parker, Kerry Ann; Parodi, Fabrizio; Parsons, John; Parzefall, Ulrich; Pasqualucci, Enrico; Passaggio, Stefano; Pastore, Fernanda; Pastore, Francesca; Pásztor, Gabriella; Pataraia, Sophio; Patel, Nikhul; Pater, Joleen; Pauly, Thilo; Pearce, James; Pearson, Benjamin; Pedersen, Lars Egholm; Pedersen, Maiken; Pedraza Lopez, Sebastian; Pedro, Rute; Peleganchuk, Sergey; Pelikan, Daniel; Penc, Ondrej; Peng, Cong; Peng, Haiping; Penning, Bjoern; Penwell, John; Perepelitsa, Dennis; Perez Codina, Estel; Pérez García-Estañ, María Teresa; Perini, Laura; Pernegger, Heinz; Perrella, Sabrina; Peschke, Richard; Peshekhonov, Vladimir; Peters, Krisztian; Peters, Yvonne; Petersen, Brian; Petersen, Troels; Petit, Elisabeth; Petridis, Andreas; Petridou, Chariclia; Petroff, Pierre; Petrolo, Emilio; Petrucci, Fabrizio; Pettersson, Nora Emilia; Pezoa, Raquel; Phillips, Peter William; Piacquadio, Giacinto; Pianori, Elisabetta; Picazio, Attilio; Piccaro, Elisa; Piccinini, Maurizio; Pickering, Mark Andrew; Piegaia, Ricardo; Pignotti, David; Pilcher, James; Pilkington, Andrew; Pina, João Antonio; Pinamonti, Michele; Pinfold, James; Pingel, Almut; Pinto, Belmiro; Pires, Sylvestre; Pirumov, Hayk; Pitt, Michael; Pizio, Caterina; Plazak, Lukas; Pleier, Marc-Andre; Pleskot, Vojtech; Plotnikova, Elena; Plucinski, Pawel; Pluth, Daniel; Poettgen, Ruth; Poggioli, Luc; Pohl, David-leon; Polesello, Giacomo; Poley, Anne-luise; Policicchio, Antonio; Polifka, Richard; Polini, Alessandro; Pollard, Christopher Samuel; Polychronakos, Venetios; Pommès, Kathy; Pontecorvo, Ludovico; Pope, Bernard; Popeneciu, Gabriel Alexandru; Popovic, Dragan; Poppleton, Alan; Pospisil, Stanislav; Potamianos, Karolos; Potrap, Igor; Potter, Christina; Potter, Christopher; Poulard, Gilbert; Poveda, Joaquin; Pozdnyakov, Valery; Pralavorio, Pascal; Pranko, Aliaksandr; Prasad, Srivas; Prell, Soeren; Price, Darren; Price, Lawrence; Primavera, Margherita; Prince, Sebastien; Proissl, Manuel; Prokofiev, Kirill; Prokoshin, Fedor; Protopapadaki, Eftychia-sofia; Protopopescu, Serban; Proudfoot, James; Przybycien, Mariusz; Ptacek, Elizabeth; Puddu, Daniele; Pueschel, Elisa; Puldon, David; Purohit, Milind; Puzo, Patrick; Qian, Jianming; Qin, Gang; Qin, Yang; Quadt, Arnulf; Quarrie, David; Quayle, William; Queitsch-Maitland, Michaela; Quilty, Donnchadha; Raddum, Silje; Radeka, Veljko; Radescu, Voica; Radhakrishnan, Sooraj Krishnan; Radloff, Peter; Rados, Pere; Ragusa, Francesco; Rahal, Ghita; Rajagopalan, Srinivasan; Rammensee, Michael; Rangel-Smith, Camila; Rauscher, Felix; Rave, Stefan; Ravenscroft, Thomas; Raymond, Michel; Read, Alexander Lincoln; Readioff, Nathan Peter; Rebuzzi, Daniela; Redelbach, Andreas; Redlinger, George; Reece, Ryan; Reeves, Kendall; Rehnisch, Laura; Reisin, Hernan; Relich, Matthew; Rembser, Christoph; Ren, Huan; Renaud, Adrien; Rescigno, Marco; Resconi, Silvia; Rezanova, Olga; Reznicek, Pavel; Rezvani, Reyhaneh; Richter, Robert; Richter, Stefan; Richter-Was, Elzbieta; Ricken, Oliver; Ridel, Melissa; Rieck, Patrick; Riegel, Christian Johann; Rieger, Julia; Rijssenbeek, Michael; Rimoldi, Adele; Rinaldi, Lorenzo; Ristić, Branislav; Ritsch, Elmar; Riu, Imma; Rizatdinova, Flera; Rizvi, Eram; Robertson, Steven; Robichaud-Veronneau, Andree; Robinson, Dave; Robinson, James; Robson, Aidan; Roda, Chiara; Roe, Shaun; Røhne, Ole; Rolli, Simona; Romaniouk, Anatoli; Romano, Marino; Romano Saez, Silvestre Marino; Romero Adam, Elena; Rompotis, Nikolaos; Ronzani, Manfredi; Roos, Lydia; Ros, Eduardo; Rosati, Stefano; Rosbach, Kilian; Rose, Peyton; Rosendahl, Peter Lundgaard; Rosenthal, Oliver; Rossetti, Valerio; Rossi, Elvira; Rossi, Leonardo Paolo; Rosten, Rachel; Rotaru, Marina; Roth, Itamar; Rothberg, Joseph; Rousseau, David; Royon, Christophe; Rozanov, Alexandre; Rozen, Yoram; Ruan, Xifeng; Rubbo, Francesco; Rubinskiy, Igor; Rud, Viacheslav; Rudolph, Christian; Rudolph, Matthew Scott; Rühr, Frederik; Ruiz-Martinez, Aranzazu; Rurikova, Zuzana; Rusakovich, Nikolai; Ruschke, Alexander; Russell, Heather; Rutherfoord, John; Ruthmann, Nils; Ryabov, Yury; Rybar, Martin; Rybkin, Grigori; Ryder, Nick; Saavedra, Aldo; Sabato, Gabriele; Sacerdoti, Sabrina; Saddique, Asif; Sadrozinski, Hartmut; Sadykov, Renat; Safai Tehrani, Francesco; Sahinsoy, Merve; Saimpert, Matthias; Saito, Tomoyuki; Sakamoto, Hiroshi; Sakurai, Yuki; Salamanna, Giuseppe; Salamon, Andrea; Saleem, Muhammad; Salek, David; Sales De Bruin, Pedro Henrique; Salihagic, Denis; Salnikov, Andrei; Salt, José; Salvatore, Daniela; Salvatore, Pasquale Fabrizio; Salvucci, Antonio; Salzburger, Andreas; Sammel, Dirk; Sampsonidis, Dimitrios; Sanchez, Arturo; Sánchez, Javier; Sanchez Martinez, Victoria; Sandaker, Heidi; Sandbach, Ruth Laura; Sander, Heinz Georg; Sanders, Michiel; Sandhoff, Marisa; Sandoval, Carlos; Sandstroem, Rikard; Sankey, Dave; Sannino, Mario; Sansoni, Andrea; Santoni, Claudio; Santonico, Rinaldo; Santos, Helena; Santoyo Castillo, Itzebelt; Sapp, Kevin; Sapronov, Andrey; Saraiva, João; Sarrazin, Bjorn; Sasaki, Osamu; Sasaki, Yuichi; Sato, Koji; Sauvage, Gilles; Sauvan, Emmanuel; Savage, Graham; Savard, Pierre; Sawyer, Craig; Sawyer, Lee; Saxon, James; Sbarra, Carla; Sbrizzi, Antonio; Scanlon, Tim; Scannicchio, Diana; Scarcella, Mark; Scarfone, Valerio; Schaarschmidt, Jana; Schacht, Peter; Schaefer, Douglas; Schaefer, Ralph; Schaeffer, Jan; Schaepe, Steffen; Schaetzel, Sebastian; Schäfer, Uli; Schaffer, Arthur; Schaile, Dorothee; Schamberger, R Dean; Scharf, Veit; Schegelsky, Valery; Scheirich, Daniel; Schernau, Michael; Schiavi, Carlo; Schillo, Christian; Schioppa, Marco; Schlenker, Stefan; Schmidt, Evelyn; Schmieden, Kristof; Schmitt, Christian; Schmitt, Sebastian; Schmitt, Stefan; Schneider, Basil; Schnellbach, Yan Jie; Schnoor, Ulrike; Schoeffel, Laurent; Schoening, Andre; Schoenrock, Bradley Daniel; Schopf, Elisabeth; Schorlemmer, Andre Lukas; Schott, Matthias; Schouten, Doug; Schovancova, Jaroslava; Schramm, Steven; Schreyer, Manuel; Schroeder, Christian; Schuh, Natascha; Schultens, Martin Johannes; Schultz-Coulon, Hans-Christian; Schulz, Holger; Schumacher, Markus; Schumm, Bruce; Schune, Philippe; Schwanenberger, Christian; Schwartzman, Ariel; Schwarz, Thomas Andrew; Schwegler, Philipp; Schweiger, Hansdieter; Schwemling, Philippe; Schwienhorst, Reinhard; Schwindling, Jerome; Schwindt, Thomas; Sciacca, Gianfranco; Scifo, Estelle; Sciolla, Gabriella; Scuri, Fabrizio; Scutti, Federico; Searcy, Jacob; Sedov, George; Sedykh, Evgeny; Seema, Pienpen; Seidel, Sally; Seiden, Abraham; Seifert, Frank; Seixas, José; Sekhniaidze, Givi; Sekhon, Karishma; Sekula, Stephen; Seliverstov, Dmitry; Semprini-Cesari, Nicola; Serfon, Cedric; Serin, Laurent; Serkin, Leonid; Serre, Thomas; Sessa, Marco; Seuster, Rolf; Severini, Horst; Sfiligoj, Tina; Sforza, Federico; Sfyrla, Anna; Shabalina, Elizaveta; Shamim, Mansoora; Shan, Lianyou; Shang, Ruo-yu; Shank, James; Shapiro, Marjorie; Shatalov, Pavel; Shaw, Kate; Shaw, Savanna Marie; Shcherbakova, Anna; Shehu, Ciwake Yusufu; Sherwood, Peter; Shi, Liaoshan; Shimizu, Shima; Shimmin, Chase Owen; Shimojima, Makoto; Shiyakova, Mariya; Shmeleva, Alevtina; Shoaleh Saadi, Diane; Shochet, Mel; Shojaii, Seyedruhollah; Shrestha, Suyog; Shulga, Evgeny; Shupe, Michael; Shushkevich, Stanislav; Sicho, Petr; Sidebo, Per Edvin; Sidiropoulou, Ourania; Sidorov, Dmitri; Sidoti, Antonio; Siegert, Frank; Sijacki, Djordje; Silva, José; Silver, Yiftah; Silverstein, Samuel; Simak, Vladislav; Simard, Olivier; Simic, Ljiljana; Simion, Stefan; Simioni, Eduard; Simmons, Brinick; Simon, Dorian; Simoniello, Rosa; Sinervo, Pekka; Sinev, Nikolai; Siragusa, Giovanni; Sisakyan, Alexei; Sivoklokov, Serguei; Sjölin, Jörgen; Sjursen, Therese; Skinner, Malcolm Bruce; Skottowe, Hugh Philip; Skubic, Patrick; Slater, Mark; Slavicek, Tomas; Slawinska, Magdalena; Sliwa, Krzysztof; Smakhtin, Vladimir; Smart, Ben; Smestad, Lillian; Smirnov, Sergei; Smirnov, Yury; Smirnova, Lidia; Smirnova, Oxana; Smith, Matthew; Smith, Russell; Smizanska, Maria; Smolek, Karel; Snesarev, Andrei; Snidero, Giacomo; Snyder, Scott; Sobie, Randall; Socher, Felix; Soffer, Abner; Soh, Dart-yin; Solans, Carlos; Solar, Michael; Solc, Jaroslav; Soldatov, Evgeny; Soldevila, Urmila; Solodkov, Alexander; Soloshenko, Alexei; Solovyanov, Oleg; Solovyev, Victor; Sommer, Philip; Song, Hong Ye; Soni, Nitesh; Sood, Alexander; Sopczak, Andre; Sopko, Bruno; Sopko, Vit; Sorin, Veronica; Sosa, David; Sosebee, Mark; Sotiropoulou, Calliope Louisa; Soualah, Rachik; Soukharev, Andrey; South, David; Sowden, Benjamin; Spagnolo, Stefania; Spalla, Margherita; Spanò, Francesco; Spearman, William Robert; Sperlich, Dennis; Spettel, Fabian; Spighi, Roberto; Spigo, Giancarlo; Spiller, Laurence Anthony; Spousta, Martin; Spreitzer, Teresa; St Denis, Richard Dante; Staerz, Steffen; Stahlman, Jonathan; Stamen, Rainer; Stamm, Soren; Stanecka, Ewa; Stanescu, Cristian; Stanescu-Bellu, Madalina; Stanitzki, Marcel Michael; Stapnes, Steinar; Starchenko, Evgeny; Stark, Jan; Staroba, Pavel; Starovoitov, Pavel; Staszewski, Rafal; Stavina, Pavel; Steinberg, Peter; Stelzer, Bernd; Stelzer, Harald Joerg; Stelzer-Chilton, Oliver; Stenzel, Hasko; Stewart, Graeme; Stillings, Jan Andre; Stockton, Mark; Stoebe, Michael; Stoicea, Gabriel; Stolte, Philipp; Stonjek, Stefan; Stradling, Alden; Straessner, Arno; Stramaglia, Maria Elena; Strandberg, Jonas; Strandberg, Sara; Strandlie, Are; Strauss, Emanuel; Strauss, Michael; Strizenec, Pavol; Ströhmer, Raimund; Strom, David; Stroynowski, Ryszard; Strubig, Antonia; Stucci, Stefania Antonia; Stugu, Bjarne; Styles, Nicholas Adam; Su, Dong; Su, Jun; Subramaniam, Rajivalochan; Succurro, Antonella; Sugaya, Yorihito; Suhr, Chad; Suk, Michal; Sulin, Vladimir; Sultansoy, Saleh; Sumida, Toshi; Sun, Siyuan; Sun, Xiaohu; Sundermann, Jan Erik; Suruliz, Kerim; Susinno, Giancarlo; Sutton, Mark; Suzuki, Shota; Svatos, Michal; Swiatlowski, Maximilian; Sykora, Ivan; Sykora, Tomas; Ta, Duc; Taccini, Cecilia; Tackmann, Kerstin; Taenzer, Joe; Taffard, Anyes; Tafirout, Reda; Taiblum, Nimrod; Takai, Helio; Takashima, Ryuichi; Takeda, Hiroshi; Takeshita, Tohru; Takubo, Yosuke; Talby, Mossadek; Talyshev, Alexey; Tam, Jason; Tan, Kong Guan; Tanaka, Junichi; Tanaka, Reisaburo; Tanaka, Shuji; Tannenwald, Benjamin Bordy; Tannoury, Nancy; Tapprogge, Stefan; Tarem, Shlomit; Tarrade, Fabien; Tartarelli, Giuseppe Francesco; Tas, Petr; Tasevsky, Marek; Tashiro, Takuya; Tassi, Enrico; Tavares Delgado, Ademar; Tayalati, Yahya; Taylor, Frank; Taylor, Geoffrey; Taylor, Wendy; Teischinger, Florian Alfred; Teixeira Dias Castanheira, Matilde; Teixeira-Dias, Pedro; Temming, Kim Katrin; Ten Kate, Herman; Teng, Ping-Kun; Teoh, Jia Jian; Tepel, Fabian-Phillipp; Terada, Susumu; Terashi, Koji; Terron, Juan; Terzo, Stefano; Testa, Marianna; Teuscher, Richard; Theveneaux-Pelzer, Timothée; Thomas, Juergen; Thomas-Wilsker, Joshuha; Thompson, Emily; Thompson, Paul; Thompson, Ray; Thompson, Stan; Thomsen, Lotte Ansgaard; Thomson, Evelyn; Thomson, Mark; Thun, Rudolf; Tibbetts, Mark James; Ticse Torres, Royer Edson; Tikhomirov, Vladimir; Tikhonov, Yury; Timoshenko, Sergey; Tiouchichine, Elodie; Tipton, Paul; Tisserant, Sylvain; Todome, Kazuki; Todorov, Theodore; Todorova-Nova, Sharka; Tojo, Junji; Tokár, Stanislav; Tokushuku, Katsuo; Tollefson, Kirsten; Tolley, Emma; Tomlinson, Lee; Tomoto, Makoto; Tompkins, Lauren; Toms, Konstantin; Torrence, Eric; Torres, Heberth; Torró Pastor, Emma; Toth, Jozsef; Touchard, Francois; Tovey, Daniel; Trefzger, Thomas; Tremblet, Louis; Tricoli, Alessandro; Trigger, Isabel Marian; Trincaz-Duvoid, Sophie; Tripiana, Martin; Trischuk, William; Trocmé, Benjamin; Troncon, Clara; Trottier-McDonald, Michel; Trovatelli, Monica; True, Patrick; Truong, Loan; Trzebinski, Maciej; Trzupek, Adam; Tsarouchas, Charilaos; Tseng, Jeffrey; Tsiareshka, Pavel; Tsionou, Dimitra; Tsipolitis, Georgios; Tsirintanis, Nikolaos; Tsiskaridze, Shota; Tsiskaridze, Vakhtang; Tskhadadze, Edisher; Tsukerman, Ilya; Tsulaia, Vakhtang; Tsuno, Soshi; Tsybychev, Dmitri; Tudorache, Alexandra; Tudorache, Valentina; Tuna, Alexander Naip; Tupputi, Salvatore; Turchikhin, Semen; Turecek, Daniel; Turra, Ruggero; Turvey, Andrew John; Tuts, Michael; Tykhonov, Andrii; Tylmad, Maja; Tyndel, Mike; Ueda, Ikuo; Ueno, Ryuichi; Ughetto, Michael; Ugland, Maren; Ukegawa, Fumihiko; Unal, Guillaume; Undrus, Alexander; Unel, Gokhan; Ungaro, Francesca; Unno, Yoshinobu; Unverdorben, Christopher; Urban, Jozef; Urquijo, Phillip; Urrejola, Pedro; Usai, Giulio; Usanova, Anna; Vacavant, Laurent; Vacek, Vaclav; Vachon, Brigitte; Valderanis, Chrysostomos; Valencic, Nika; Valentinetti, Sara; Valero, Alberto; Valery, Loic; Valkar, Stefan; Valladolid Gallego, Eva; Vallecorsa, Sofia; Valls Ferrer, Juan Antonio; Van Den Wollenberg, Wouter; Van Der Deijl, Pieter; van der Geer, Rogier; van der Graaf, Harry; Van Der Leeuw, Robin; van Eldik, Niels; van Gemmeren, Peter; Van Nieuwkoop, Jacobus; van Vulpen, Ivo; van Woerden, Marius Cornelis; Vanadia, Marco; Vandelli, Wainer; Vanguri, Rami; Vaniachine, Alexandre; Vannucci, Francois; Vardanyan, Gagik; Vari, Riccardo; Varnes, Erich; Varol, Tulin; Varouchas, Dimitris; Vartapetian, Armen; Varvell, Kevin; Vazeille, Francois; Vazquez Schroeder, Tamara; Veatch, Jason; Veloce, Laurelle Maria; Veloso, Filipe; Velz, Thomas; Veneziano, Stefano; Ventura, Andrea; Ventura, Daniel; Venturi, Manuela; Venturi, Nicola; Venturini, Alessio; Vercesi, Valerio; Verducci, Monica; Verkerke, Wouter; Vermeulen, Jos; Vest, Anja; Vetterli, Michel; Viazlo, Oleksandr; Vichou, Irene; Vickey, Trevor; Vickey Boeriu, Oana Elena; Viehhauser, Georg; Viel, Simon; Vigne, Ralph; Villa, Mauro; Villaplana Perez, Miguel; Vilucchi, Elisabetta; Vincter, Manuella; Vinogradov, Vladimir; Vivarelli, Iacopo; Vives Vaque, Francesc; Vlachos, Sotirios; Vladoiu, Dan; Vlasak, Michal; Vogel, Marcelo; Vokac, Petr; Volpi, Guido; Volpi, Matteo; von der Schmitt, Hans; von Radziewski, Holger; von Toerne, Eckhard; Vorobel, Vit; Vorobev, Konstantin; Vos, Marcel; Voss, Rudiger; Vossebeld, Joost; Vranjes, Nenad; Vranjes Milosavljevic, Marija; Vrba, Vaclav; Vreeswijk, Marcel; Vuillermet, Raphael; Vukotic, Ilija; Vykydal, Zdenek; Wagner, Peter; Wagner, Wolfgang; Wahlberg, Hernan; Wahrmund, Sebastian; Wakabayashi, Jun; Walder, James; Walker, Rodney; Walkowiak, Wolfgang; Wang, Chao; Wang, Fuquan; Wang, Haichen; Wang, Hulin; Wang, Jike; Wang, Jin; Wang, Kuhan; Wang, Rui; Wang, Song-Ming; Wang, Tan; Wang, Xiaoxiao; Wanotayaroj, Chaowaroj; Warburton, Andreas; Ward, Patricia; Wardrope, David Robert; Washbrook, Andrew; Wasicki, Christoph; Watkins, Peter; Watson, Alan; Watson, Ian; Watson, Miriam; Watts, Gordon; Watts, Stephen; Waugh, Ben; Webb, Samuel; Weber, Michele; Weber, Stefan Wolf; Webster, Jordan S; Weidberg, Anthony; Weinert, Benjamin; Weingarten, Jens; Weiser, Christian; Weits, Hartger; Wells, Phillippa; Wenaus, Torre; Wengler, Thorsten; Wenig, Siegfried; Wermes, Norbert; Werner, Matthias; Werner, Per; Wessels, Martin; Wetter, Jeffrey; Whalen, Kathleen; Wharton, Andrew Mark; White, Andrew; White, Martin; White, Ryan; White, Sebastian; Whiteson, Daniel; Wickens, Fred; Wiedenmann, Werner; Wielers, Monika; Wienemann, Peter; Wiglesworth, Craig; Wiik-Fuchs, Liv Antje Mari; Wildauer, Andreas; Wilkens, Henric George; Williams, Hugh; Williams, Sarah; Willis, Christopher; Willocq, Stephane; Wilson, Alan; Wilson, John; Wingerter-Seez, Isabelle; Winklmeier, Frank; Winter, Benedict Tobias; Wittgen, Matthias; Wittkowski, Josephine; Wollstadt, Simon Jakob; Wolter, Marcin Wladyslaw; Wolters, Helmut; Wosiek, Barbara; Wotschack, Jorg; Woudstra, Martin; Wozniak, Krzysztof; Wu, Mengqing; Wu, Miles; Wu, Sau Lan; Wu, Xin; Wu, Yusheng; Wyatt, Terry Richard; Wynne, Benjamin; Xella, Stefania; Xu, Da; Xu, Lailin; Yabsley, Bruce; Yacoob, Sahal; Yakabe, Ryota; Yamada, Miho; Yamaguchi, Yohei; Yamamoto, Akira; Yamamoto, Shimpei; Yamanaka, Takashi; Yamauchi, Katsuya; Yamazaki, Yuji; Yan, Zhen; Yang, Haijun; Yang, Hongtao; Yang, Yi; Yao, Weiming; Yasu, Yoshiji; Yatsenko, Elena; Yau Wong, Kaven Henry; Ye, Jingbo; Ye, Shuwei; Yeletskikh, Ivan; Yen, Andy L; Yildirim, Eda; Yorita, Kohei; Yoshida, Rikutaro; Yoshihara, Keisuke; Young, Charles; Young, Christopher John; Youssef, Saul; Yu, David Ren-Hwa; Yu, Jaehoon; Yu, Jiaming; Yu, Jie; Yuan, Li; Yuen, Stephanie P; Yurkewicz, Adam; Yusuff, Imran; Zabinski, Bartlomiej; Zaidan, Remi; Zaitsev, Alexander; Zalieckas, Justas; Zaman, Aungshuman; Zambito, Stefano; Zanello, Lucia; Zanzi, Daniele; Zeitnitz, Christian; Zeman, Martin; Zemla, Andrzej; Zengel, Keith; Zenin, Oleg; Ženiš, Tibor; Zerwas, Dirk; Zhang, Dongliang; Zhang, Fangzhou; Zhang, Huijun; Zhang, Jinlong; Zhang, Lei; Zhang, Ruiqi; Zhang, Xueyao; Zhang, Zhiqing; Zhao, Xiandong; Zhao, Yongke; Zhao, Zhengguo; Zhemchugov, Alexey; Zhong, Jiahang; Zhou, Bing; Zhou, Chen; Zhou, Lei; Zhou, Li; Zhou, Ning; Zhu, Cheng Guang; Zhu, Hongbo; Zhu, Junjie; Zhu, Yingchun; Zhuang, Xuai; Zhukov, Konstantin; Zibell, Andre; Zieminska, Daria; Zimine, Nikolai; Zimmermann, Christoph; Zimmermann, Stephanie; Zinonos, Zinonas; Zinser, Markus; Ziolkowski, Michael; Živković, Lidija; Zobernig, Georg; Zoccoli, Antonio; zur Nedden, Martin; Zurzolo, Giovanni; Zwalinski, Lukasz

    2015-09-03

    Many extensions of the Standard Model predict the existence of charged heavy long-lived particles, such as $R$-hadrons or charginos. These particles, if produced at the Large Hadron Collider, should be moving non-relativistically and are therefore identifiable through the measurement of an anomalously large specific energy loss in the ATLAS pixel detector. Measuring heavy long-lived particles through their track parameters in the vicinity of the interaction vertex provides sensitivity to metastable particles with lifetimes from 0.6 ns to 30 ns. A search for such particles with the ATLAS detector at the Large Hadron Collider is presented, based on a data sample corresponding to an integrated luminosity of 18.4 fb$^{-1}$ of $pp$ collisions at $\\sqrt{s}$ = 8 TeV. No significant deviation from the Standard Model background expectation is observed, and lifetime-dependent upper limits on $R$-hadrons and chargino production are set. Gluino $R$-hadrons with 10 ns lifetime and masses up to 1185 GeV are excluded at 95%...

  8. Italian Physical Society Search for metastable heavy charged particles with large ionisation energy loss in $pp$ collisions at $\\sqrt s = 13$ TeV using the ATLAS experiment

    CERN Document Server

    Gaudiello, A

    2017-01-01

    Many extensions of the Standard Model predict the existence of charged and heavy long-lived particles, such as R-hadrons. These particles, if produced at the Large Hadron Collider (LHC), should be non-relativistic and are therefore identifiable through the measurement of an anomalously large energy loss in the ATLAS Pixel Detector. The search for heavy long-lived particles using track information in the vicinity of the interaction vertex is sensitive for values of their lifetime in the nanosecond range. The research of metastable and stable R-hadrons with the ATLAS detector using 2015 LHC data is here reported.

  9. Esophageal Toxicity From High-Dose, Single-Fraction Paraspinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Cox, Brett W.; Jackson, Andrew; Hunt, Margie; Bilsky, Mark; Yamada, Yoshiya

    2012-01-01

    Purpose: To report the esophageal toxicity from single-fraction paraspinal stereotactic radiosurgery (SRS) and identify dosimetric and clinical risk factors for toxicity. Methods and Materials: A total of 204 spinal metastases abutting the esophagus (182 patients) were treated with high-dose single-fraction SRS during 2003-2010. Toxicity was scored using the National Cancer Institute Common Toxicity Criteria for Adverse Events, version 4.0. Dose-volume histograms were combined to generate a comprehensive atlas of complication incidence that identifies risk factors for toxicity. Correlation of dose-volume factors with esophageal toxicity was assessed using Fisher’s exact test and logistic regression. Clinical factors were correlated with toxicity. Results: The median dose to the planning treatment volume was 24 Gy. Median follow-up was 12 months (range, 3-81). There were 31 (15%) acute and 24 (12%) late esophageal toxicities. The rate of grade ≥3 acute or late toxicity was 6.8% (14 patients). Fisher’s exact test resulted in significant median splits for grade ≥3 toxicity at V12 = 3.78 cm 3 (relative risk [RR] 3.7, P=.05), V15 = 1.87 cm 3 (RR 13, P=.0013), V20 = 0.11 cm 3 (RR 6, P=0.01), and V22 = 0.0 cm 3 (RR 13, P=.0013). The median split for D2.5 cm 3 (14.02 Gy) was also a significant predictor of toxicity (RR 6; P=.01). A highly significant logistic regression model was generated on the basis of D2.5 cm 3 . One hundred percent (n = 7) of grade ≥4 toxicities were associated with radiation recall reactions after doxorubicin or gemcitabine chemotherapy or iatrogenic manipulation of the irradiated esophagus. Conclusions: High-dose, single-fraction paraspinal SRS has a low rate of grade ≥3 esophageal toxicity. Severe esophageal toxicity is minimized with careful attention to esophageal doses during treatment planning. Iatrogenic manipulation of the irradiated esophagus and systemic agents classically associated with radiation recall reactions are

  10. A concise review of the efficacy of stereotactic radiosurgery in the management of melanoma and renal cell carcinoma brain metastases

    Directory of Open Access Journals (Sweden)

    Hanson Peter W

    2012-08-01

    Full Text Available Abstract Melanoma and renal cell carcinoma have a well-documented tendency to develop metastases to the brain. Treating these lesions has traditionally been problematic, because chemotherapy has difficulty crossing the blood brain barrier and whole brain radiation therapy (WBRT is a relatively ineffective treatment against these radioresistant tumor histologies. In recent years, stereotactic radiosurgery (SRS has emerged as an effective and minimally-invasive treatment modality for irradiating either single or multiple intracranial structures in one clinical treatment setting. For this reason, we conducted a review of modern literature analyzing the efficacy of SRS in the management of patients with melanoma and renal cell carcinoma brain metastases. In our analysis we found SRS to be a safe, effective and attractive treatment modality for managing radioresistant brain metastases and highlighted the need for randomized trials comparing WBRT alone vs. SRS alone vs. WBRT plus SRS in treating patients with radioresistant brain metastases.

  11. Concurrent Stereotactic Radiosurgery and Bevacizumab in Recurrent Malignant Gliomas: A Prospective Trial

    International Nuclear Information System (INIS)

    Cabrera, Alvin R.; Cuneo, Kyle C.; Desjardins, Annick; Sampson, John H.; McSherry, Frances; Herndon, James E.; Peters, Katherine B.; Allen, Karen; Hoang, Jenny K.; Chang, Zheng; Craciunescu, Oana; Vredenburgh, James J.; Friedman, Henry S.; Kirkpatrick, John P.

    2013-01-01

    Purpose: Virtually all patients with malignant glioma (MG) eventually recur. This study evaluates the safety of concurrent stereotactic radiosurgery (SRS) and bevacizumab (BVZ), an antiangiogenic agent, in treatment of recurrent MG. Methods and Materials: Fifteen patients with recurrent MG, treated at initial diagnosis with surgery and adjuvant radiation therapy/temozolomide and then at least 1 salvage chemotherapy regimen, were enrolled in this prospective trial. Lesions <3 cm in diameter were treated in a single fraction, whereas those 3 to 5 cm in diameter received 5 5-Gy fractions. BVZ was administered immediately before SRS and 2 weeks later. Neurocognitive testing (Mini-Mental Status Exam, Trail Making Test A/B), Functional Assessment of Cancer Therapy-Brain (FACT-Br) quality-of-life assessment, physical exam, and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) were performed immediately before SRS and 1 week and 2 months following completion of SRS. The primary endpoint was central nervous system (CNS) toxicity. Secondary endpoints included survival, quality of life, microvascular properties as measured by DCE-MRI, steroid usage, and performance status. Results: One grade 3 (severe headache) and 2 grade 2 CNS toxicities were observed. No patients experienced grade 4 to 5 toxicity or intracranial hemorrhage. Neurocognition, quality of life, and Karnofsky performance status did not change significantly with treatment. DCE-MRI results suggest a significant decline in tumor perfusion and permeability 1 week after SRS and further decline by 2 months. Conclusions: Treatment of recurrent MG with concurrent SRS and BVZ was not associated with excessive toxicity in this prospective trial. A randomized trial of concurrent SRS/BVZ versus conventional salvage therapy is needed to establish the efficacy of this approach

  12. Search for heavy long-lived charged particles in pp collisions at $\\sqrt{s}$=7 TeV

    CERN Document Server

    Chatrchyan, Serguei; Sirunyan, Albert M; Tumasyan, Armen; Adam, Wolfgang; Bergauer, Thomas; Dragicevic, Marko; Erö, Janos; Fabjan, Christian; Friedl, Markus; Fruehwirth, Rudolf; Ghete, Vasile Mihai; Hammer, Josef; Hörmann, Natascha; Hrubec, Josef; Jeitler, Manfred; Kiesenhofer, Wolfgang; Knünz, Valentin; Krammer, Manfred; Liko, Dietrich; Mikulec, Ivan; Pernicka, Manfred; Rahbaran, Babak; Rohringer, Christine; Rohringer, Herbert; Schöfbeck, Robert; Strauss, Josef; Taurok, Anton; Teischinger, Florian; Wagner, Philipp; Waltenberger, Wolfgang; Walzel, Gerhard; Widl, Edmund; Wulz, Claudia-Elisabeth; Mossolov, Vladimir; Shumeiko, Nikolai; Suarez Gonzalez, Juan; Bansal, Sunil; Cerny, Karel; Cornelis, Tom; De Wolf, Eddi A; Janssen, Xavier; Luyckx, Sten; Maes, Thomas; Mucibello, Luca; Ochesanu, Silvia; Roland, Benoit; Rougny, Romain; Selvaggi, Michele; Van Haevermaet, Hans; Van Mechelen, Pierre; Van Remortel, Nick; Van Spilbeeck, Alex; Blekman, Freya; Blyweert, Stijn; D'Hondt, Jorgen; Gonzalez Suarez, Rebeca; Kalogeropoulos, Alexis; Maes, Michael; Olbrechts, Annik; Van Doninck, Walter; Van Mulders, Petra; Van Onsem, Gerrit Patrick; Villella, Ilaria; Charaf, Otman; Clerbaux, Barbara; De Lentdecker, Gilles; Dero, Vincent; Gay, Arnaud; Hreus, Tomas; Léonard, Alexandre; Marage, Pierre Edouard; Reis, Thomas; Thomas, Laurent; Vander Velde, Catherine; Vanlaer, Pascal; Adler, Volker; Beernaert, Kelly; Cimmino, Anna; Costantini, Silvia; Garcia, Guillaume; Grunewald, Martin; Klein, Benjamin; Lellouch, Jérémie; Marinov, Andrey; Mccartin, Joseph; Ocampo Rios, Alberto Andres; Ryckbosch, Dirk; Strobbe, Nadja; Thyssen, Filip; Tytgat, Michael; Vanelderen, Lukas; Verwilligen, Piet; Walsh, Sinead; Yazgan, Efe; Zaganidis, Nicolas; Basegmez, Suzan; Bruno, Giacomo; Ceard, Ludivine; Delaere, Christophe; Du Pree, Tristan; Favart, Denis; Forthomme, Laurent; Giammanco, Andrea; Hollar, Jonathan; Lemaitre, Vincent; Liao, Junhui; Militaru, Otilia; Nuttens, Claude; Pagano, Davide; Pin, Arnaud; Piotrzkowski, Krzysztof; Schul, Nicolas; Beliy, Nikita; Caebergs, Thierry; Daubie, Evelyne; Hammad, Gregory Habib; Alves, Gilvan; Correa Martins Junior, Marcos; De Jesus Damiao, Dilson; Martins, Thiago; Pol, Maria Elena; Henrique Gomes E Souza, Moacyr; Aldá Júnior, Walter Luiz; Carvalho, Wagner; Custódio, Analu; Melo Da Costa, Eliza; De Oliveira Martins, Carley; Fonseca De Souza, Sandro; Matos Figueiredo, Diego; Mundim, Luiz; Nogima, Helio; Oguri, Vitor; Prado Da Silva, Wanda Lucia; Santoro, Alberto; Silva Do Amaral, Sheila Mara; Soares Jorge, Luana; Sznajder, Andre; Souza Dos Anjos, Tiago; Bernardes, Cesar Augusto; De Almeida Dias, Flavia; Tomei, Thiago; De Moraes Gregores, Eduardo; Lagana, Caio; Da Cunha Marinho, Franciole; Mercadante, Pedro G; Novaes, Sergio F; Padula, Sandra; Genchev, Vladimir; Iaydjiev, Plamen; Piperov, Stefan; Rodozov, Mircho; Stoykova, Stefka; Sultanov, Georgi; Tcholakov, Vanio; Trayanov, Rumen; Vutova, Mariana; Dimitrov, Anton; Hadjiiska, Roumyana; Kozhuharov, Venelin; Litov, Leander; Pavlov, Borislav; Petkov, Peicho; Bian, Jian-Guo; Chen, Guo-Ming; Chen, He-Sheng; Jiang, Chun-Hua; Liang, Dong; Liang, Song; Meng, Xiangwei; Tao, Junquan; Wang, Jian; Wang, Jian; Wang, Xianyou; Wang, Zheng; Xiao, Hong; Xu, Ming; Zang, Jingjing; Zhang, Zhen; Asawatangtrakuldee, Chayanit; Ban, Yong; Guo, Shuang; Guo, Yifei; Li, Wenbo; Liu, Shuai; Mao, Yajun; Qian, Si-Jin; Teng, Haiyun; Wang, Siguang; Zhu, Bo; Zou, Wei; Avila, Carlos; Gomez Moreno, Bernardo; Osorio Oliveros, Andres Felipe; Sanabria, Juan Carlos; Godinovic, Nikola; Lelas, Damir; Plestina, Roko; Polic, Dunja; Puljak, Ivica; Antunovic, Zeljko; Dzelalija, Mile; Kovac, Marko; Brigljevic, Vuko; Duric, Senka; Kadija, Kreso; Luetic, Jelena; Morovic, Srecko; Attikis, Alexandros; Galanti, Mario; Mavromanolakis, Georgios; Mousa, Jehad; Nicolaou, Charalambos; Ptochos, Fotios; Razis, Panos A; Finger, Miroslav; Finger Jr, Michael; Assran, Yasser; Elgammal, Sherif; Ellithi Kamel, Ali; Khalil, Shaaban; Mahmoud, Mohammed; Radi, Amr; Kadastik, Mario; Müntel, Mait; Raidal, Martti; Rebane, Liis; Tiko, Andres; Azzolini, Virginia; Eerola, Paula; Fedi, Giacomo; Voutilainen, Mikko; Härkönen, Jaakko; Heikkinen, Mika Aatos; Karimäki, Veikko; Kinnunen, Ritva; Kortelainen, Matti J; Lampén, Tapio; Lassila-Perini, Kati; Lehti, Sami; Lindén, Tomas; Luukka, Panja-Riina; Mäenpää, Teppo; Peltola, Timo; Tuominen, Eija; Tuominiemi, Jorma; Tuovinen, Esa; Ungaro, Donatella; Wendland, Lauri; Banzuzi, Kukka; Korpela, Arja; Tuuva, Tuure; Besancon, Marc; Choudhury, Somnath; Dejardin, Marc; Denegri, Daniel; Fabbro, Bernard; Faure, Jean-Louis; Ferri, Federico; Ganjour, Serguei; Givernaud, Alain; Gras, Philippe; Hamel de Monchenault, Gautier; Jarry, Patrick; Locci, Elizabeth; Malcles, Julie; Millischer, Laurent; Nayak, Aruna; Rander, John; Rosowsky, André; Shreyber, Irina; Titov, Maksym; Baffioni, Stephanie; Beaudette, Florian; Benhabib, Lamia; Bianchini, Lorenzo; Bluj, Michal; Broutin, Clementine; Busson, Philippe; Charlot, Claude; Daci, Nadir; Dahms, Torsten; Dobrzynski, Ludwik; Granier de Cassagnac, Raphael; Haguenauer, Maurice; Miné, Philippe; Mironov, Camelia; Ochando, Christophe; Paganini, Pascal; Sabes, David; Salerno, Roberto; Sirois, Yves; Veelken, Christian; Zabi, Alexandre; Agram, Jean-Laurent; Andrea, Jeremy; Bloch, Daniel; Bodin, David; Brom, Jean-Marie; Cardaci, Marco; Chabert, Eric Christian; Collard, Caroline; Conte, Eric; Drouhin, Frédéric; Ferro, Cristina; Fontaine, Jean-Charles; Gelé, Denis; Goerlach, Ulrich; Juillot, Pierre; Karim, Mehdi; Le Bihan, Anne-Catherine; Van Hove, Pierre; Fassi, Farida; Mercier, Damien; Beauceron, Stephanie; Beaupere, Nicolas; Bondu, Olivier; Boudoul, Gaelle; Brun, Hugues; Chasserat, Julien; Chierici, Roberto; Contardo, Didier; Depasse, Pierre; El Mamouni, Houmani; Fay, Jean; Gascon, Susan; Gouzevitch, Maxime; Ille, Bernard; Kurca, Tibor; Lethuillier, Morgan; Mirabito, Laurent; Perries, Stephane; Sordini, Viola; Tosi, Silvano; Tschudi, Yohann; Verdier, Patrice; Viret, Sébastien; Tsamalaidze, Zviad; Anagnostou, Georgios; Beranek, Sarah; Edelhoff, Matthias; Feld, Lutz; Heracleous, Natalie; Hindrichs, Otto; Jussen, Ruediger; Klein, Katja; Merz, Jennifer; Ostapchuk, Andrey; Perieanu, Adrian; Raupach, Frank; Sammet, Jan; Schael, Stefan; Sprenger, Daniel; Weber, Hendrik; Wittmer, Bruno; Zhukov, Valery; Ata, Metin; Caudron, Julien; Dietz-Laursonn, Erik; Duchardt, Deborah; Erdmann, Martin; Güth, Andreas; Hebbeker, Thomas; Heidemann, Carsten; Hoepfner, Kerstin; Klimkovich, Tatsiana; Klingebiel, Dennis; Kreuzer, Peter; Lanske, Dankfried; Lingemann, Joschka; Magass, Carsten; Merschmeyer, Markus; Meyer, Arnd; Olschewski, Mark; Papacz, Paul; Pieta, Holger; Reithler, Hans; Schmitz, Stefan Antonius; Sonnenschein, Lars; Steggemann, Jan; Teyssier, Daniel; Weber, Martin; Bontenackels, Michael; Cherepanov, Vladimir; Davids, Martina; Flügge, Günter; Geenen, Heiko; Geisler, Matthias; Haj Ahmad, Wael; Hoehle, Felix; Kargoll, Bastian; Kress, Thomas; Kuessel, Yvonne; Linn, Alexander; Nowack, Andreas; Perchalla, Lars; Pooth, Oliver; Rennefeld, Jörg; Sauerland, Philip; Stahl, Achim; Aldaya Martin, Maria; Behr, Joerg; Behrenhoff, Wolf; Behrens, Ulf; Bergholz, Matthias; Bethani, Agni; Borras, Kerstin; Burgmeier, Armin; Cakir, Altan; Calligaris, Luigi; Campbell, Alan; Castro, Elena; Costanza, Francesco; Dammann, Dirk; Eckerlin, Guenter; Eckstein, Doris; Fischer, David; Flucke, Gero; Geiser, Achim; Glushkov, Ivan; Habib, Shiraz; Hauk, Johannes; Jung, Hannes; Kasemann, Matthias; Katsas, Panagiotis; Kleinwort, Claus; Kluge, Hannelies; Knutsson, Albert; Krämer, Mira; Krücker, Dirk; Kuznetsova, Ekaterina; Lange, Wolfgang; Lohmann, Wolfgang; Lutz, Benjamin; Mankel, Rainer; Marfin, Ihar; Marienfeld, Markus; Melzer-Pellmann, Isabell-Alissandra; Meyer, Andreas Bernhard; Mnich, Joachim; Mussgiller, Andreas; Naumann-Emme, Sebastian; Olzem, Jan; Perrey, Hanno; Petrukhin, Alexey; Pitzl, Daniel; Raspereza, Alexei; Ribeiro Cipriano, Pedro M; Riedl, Caroline; Rosin, Michele; Salfeld-Nebgen, Jakob; Schmidt, Ringo; Schoerner-Sadenius, Thomas; Sen, Niladri; Spiridonov, Alexander; Stein, Matthias; Walsh, Roberval; Wissing, Christoph; Autermann, Christian; Blobel, Volker; Bobrovskyi, Sergei; Draeger, Jula; Enderle, Holger; Erfle, Joachim; Gebbert, Ulla; Görner, Martin; Hermanns, Thomas; Höing, Rebekka Sophie; Kaschube, Kolja; Kaussen, Gordon; Kirschenmann, Henning; Klanner, Robert; Lange, Jörn; Mura, Benedikt; Nowak, Friederike; Pietsch, Niklas; Rathjens, Denis; Sander, Christian; Schettler, Hannes; Schleper, Peter; Schlieckau, Eike; Schmidt, Alexander; Schröder, Matthias; Schum, Torben; Seidel, Markus; Stadie, Hartmut; Steinbrück, Georg; Thomsen, Jan; Barth, Christian; Berger, Joram; Chwalek, Thorsten; De Boer, Wim; Dierlamm, Alexander; Feindt, Michael; Guthoff, Moritz; Hackstein, Christoph; Hartmann, Frank; Heinrich, Michael; Held, Hauke; Hoffmann, Karl-Heinz; Honc, Simon; Katkov, Igor; Komaragiri, Jyothsna Rani; Martschei, Daniel; Mueller, Steffen; Müller, Thomas; Niegel, Martin; Nürnberg, Andreas; Oberst, Oliver; Oehler, Andreas; Ott, Jochen; Peiffer, Thomas; Quast, Gunter; Rabbertz, Klaus; Ratnikov, Fedor; Ratnikova, Natalia; Röcker, Steffen; Saout, Christophe; Scheurer, Armin; Schilling, Frank-Peter; Schmanau, Mike; Schott, Gregory; Simonis, Hans-Jürgen; Stober, Fred-Markus Helmut; Troendle, Daniel; Ulrich, Ralf; Wagner-Kuhr, Jeannine; Weiler, Thomas; Zeise, Manuel; Ziebarth, Eva Barbara; Daskalakis, Georgios; Geralis, Theodoros; Kesisoglou, Stilianos; Kyriakis, Aristotelis; Loukas, Demetrios; Manolakos, Ioannis; Markou, Athanasios; Markou, Christos; Mavrommatis, Charalampos; Ntomari, Eleni; Gouskos, Loukas; Mertzimekis, Theodoros; Panagiotou, Apostolos; Saoulidou, Niki; Evangelou, Ioannis; Foudas, Costas; Kokkas, Panagiotis; Manthos, Nikolaos; Papadopoulos, Ioannis; Patras, Vaios; Bencze, Gyorgy; Hajdu, Csaba; Hidas, Pàl; Horvath, Dezso; Krajczar, Krisztian; Radics, Balint; Sikler, Ferenc; Veszpremi, Viktor; Vesztergombi, Gyorgy; Beni, Noemi; Czellar, Sandor; Molnar, Jozsef; Palinkas, Jozsef; Szillasi, Zoltan; Karancsi, János; Raics, Peter; Trocsanyi, Zoltan Laszlo; Ujvari, Balazs; Beri, Suman Bala; Bhatnagar, Vipin; Dhingra, Nitish; Gupta, Ruchi; Jindal, Monika; Kaur, Manjit; Kohli, Jatinder Mohan; Mehta, Manuk Zubin; Nishu, Nishu; Saini, Lovedeep Kaur; Sharma, Archana; Singh, Jasbir; Singh, Supreet Pal; Ahuja, Sudha; Bhardwaj, Ashutosh; Choudhary, Brajesh C; Kumar, Ashok; Kumar, Arun; Malhotra, Shivali; Naimuddin, Md; Ranjan, Kirti; Sharma, Varun; Shivpuri, Ram Krishen; Banerjee, Sunanda; Bhattacharya, Satyaki; Dutta, Suchandra; Gomber, Bhawna; Jain, Sandhya; Jain, Shilpi; Khurana, Raman; Sarkar, Subir; Abdulsalam, Abdulla; Choudhury, Rajani Kant; Dutta, Dipanwita; Kailas, Swaminathan; Kumar, Vineet; Mohanty, Ajit Kumar; Pant, Lalit Mohan; Shukla, Prashant; Aziz, Tariq; Ganguly, Sanmay; Guchait, Monoranjan; Gurtu, Atul; Maity, Manas; Majumder, Gobinda; Mazumdar, Kajari; Mohanty, Gagan Bihari; Parida, Bibhuti; Sudhakar, Katta; Wickramage, Nadeesha; Banerjee, Sudeshna; Dugad, Shashikant; Arfaei, Hessamaddin; Bakhshiansohi, Hamed; Etesami, Seyed Mohsen; Fahim, Ali; Hashemi, Majid; Hesari, Hoda; Jafari, Abideh; Khakzad, Mohsen; Mohammadi, Abdollah; Mohammadi Najafabadi, Mojtaba; Paktinat Mehdiabadi, Saeid; Safarzadeh, Batool; Zeinali, Maryam; Abbrescia, Marcello; Barbone, Lucia; Calabria, Cesare; Chhibra, Simranjit Singh; Colaleo, Anna; Creanza, Donato; De Filippis, Nicola; De Palma, Mauro; Fiore, Luigi; Iaselli, Giuseppe; Lusito, Letizia; Maggi, Giorgio; Maggi, Marcello; Marangelli, Bartolomeo; My, Salvatore; Nuzzo, Salvatore; Pacifico, Nicola; Pompili, Alexis; Pugliese, Gabriella; Selvaggi, Giovanna; Silvestris, Lucia; Singh, Gurpreet; Zito, Giuseppe; Abbiendi, Giovanni; Benvenuti, Alberto; Bonacorsi, Daniele; Braibant-Giacomelli, Sylvie; Brigliadori, Luca; Capiluppi, Paolo; Castro, Andrea; Cavallo, Francesca Romana; Cuffiani, Marco; Dallavalle, Gaetano-Marco; Fabbri, Fabrizio; Fanfani, Alessandra; Fasanella, Daniele; Giacomelli, Paolo; Grandi, Claudio; Guiducci, Luigi; Marcellini, Stefano; Masetti, Gianni; Meneghelli, Marco; Montanari, Alessandro; Navarria, Francesco; Odorici, Fabrizio; Perrotta, Andrea; Primavera, Federica; Rossi, Antonio; Rovelli, Tiziano; Siroli, Gianni; Travaglini, Riccardo; Albergo, Sebastiano; Cappello, Gigi; Chiorboli, Massimiliano; Costa, Salvatore; Potenza, Renato; Tricomi, Alessia; Tuve, Cristina; Barbagli, Giuseppe; Ciulli, Vitaliano; Civinini, Carlo; D'Alessandro, Raffaello; Focardi, Ettore; Frosali, Simone; Gallo, Elisabetta; Gonzi, Sandro; Meschini, Marco; Paoletti, Simone; Sguazzoni, Giacomo; Tropiano, Antonio; Benussi, Luigi; Bianco, Stefano; Colafranceschi, Stefano; Fabbri, Franco; Piccolo, Davide; Fabbricatore, Pasquale; Musenich, Riccardo; Benaglia, Andrea; De Guio, Federico; Di Matteo, Leonardo; Fiorendi, Sara; Gennai, Simone; Ghezzi, Alessio; Malvezzi, Sandra; Manzoni, Riccardo Andrea; Martelli, Arabella; Massironi, Andrea; Menasce, Dario; Moroni, Luigi; Paganoni, Marco; Pedrini, Daniele; Ragazzi, Stefano; Redaelli, Nicola; Sala, Silvano; Tabarelli de Fatis, Tommaso; Buontempo, Salvatore; Carrillo Montoya, Camilo Andres; Cavallo, Nicola; De Cosa, Annapaola; Dogangun, Oktay; Fabozzi, Francesco; Iorio, Alberto Orso Maria; Lista, Luca; Meola, Sabino; Merola, Mario; Paolucci, Pierluigi; Azzi, Patrizia; Bacchetta, Nicola; Bellan, Paolo; Bisello, Dario; Branca, Antonio; Carlin, Roberto; Checchia, Paolo; Dorigo, Tommaso; Gasparini, Fabrizio; Gasparini, Ugo; Gozzelino, Andrea; Kanishchev, Konstantin; Lacaprara, Stefano; Lazzizzera, Ignazio; Margoni, Martino; Meneguzzo, Anna Teresa; Nespolo, Massimo; Perrozzi, Luca; Pozzobon, Nicola; Ronchese, Paolo; Simonetto, Franco; Torassa, Ezio; Tosi, Mia; Vanini, Sara; Zotto, Pierluigi; Gabusi, Michele; Ratti, Sergio P; Riccardi, Cristina; Torre, Paola; Vitulo, Paolo; Bilei, Gian Mario; Fanò, Livio; Lariccia, Paolo; Lucaroni, Andrea; Mantovani, Giancarlo; Menichelli, Mauro; Nappi, Aniello; Romeo, Francesco; Saha, Anirban; Santocchia, Attilio; Taroni, Silvia; Azzurri, Paolo; Bagliesi, Giuseppe; Boccali, Tommaso; Broccolo, Giuseppe; Castaldi, Rino; D'Agnolo, Raffaele Tito; Dell'Orso, Roberto; Fiori, Francesco; Foà, Lorenzo; Giassi, Alessandro; Kraan, Aafke; Ligabue, Franco; Lomtadze, Teimuraz; Martini, Luca; Messineo, Alberto; Palla, Fabrizio; Palmonari, Francesco; Rizzi, Andrea; Serban, Alin Titus; Spagnolo, Paolo; Squillacioti, Paola; Tenchini, Roberto; Tonelli, Guido; Venturi, Andrea; Verdini, Piero Giorgio; Barone, Luciano; Cavallari, Francesca; Del Re, Daniele; Diemoz, Marcella; Fanelli, Cristiano; Grassi, Marco; Longo, Egidio; Meridiani, Paolo; Micheli, Francesco; Nourbakhsh, Shervin; Organtini, Giovanni; Pandolfi, Francesco; Paramatti, Riccardo; Rahatlou, Shahram; Sigamani, Michael; Soffi, Livia; Amapane, Nicola; Arcidiacono, Roberta; Argiro, Stefano; Arneodo, Michele; Biino, Cristina; Botta, Cristina; Cartiglia, Nicolo; Castello, Roberto; Costa, Marco; Dellacasa, Giulio; Demaria, Natale; Graziano, Alberto; Mariotti, Chiara; Maselli, Silvia; Migliore, Ernesto; Monaco, Vincenzo; Musich, Marco; Obertino, Maria Margherita; Pastrone, Nadia; Pelliccioni, Mario; Potenza, Alberto; Romero, Alessandra; Ruspa, Marta; Sacchi, Roberto; Solano, Ada; Staiano, Amedeo; Vilela Pereira, Antonio; Belforte, Stefano; Cossutti, Fabio; Della Ricca, Giuseppe; Gobbo, Benigno; Marone, Matteo; Montanino, Damiana; Penzo, Aldo; Schizzi, Andrea; Heo, Seong Gu; Kim, Tae Yeon; Nam, Soon-Kwon; Chang, Sunghyun; Chung, Jin Hyuk; Kim, Dong Hee; Kim, Gui Nyun; Kong, Dae Jung; Park, Hyangkyu; Ro, Sang-Ryul; Son, Dong-Chul; Son, Taejin; Kim, Jae Yool; Kim, Zero Jaeho; Song, Sanghyeon; Jo, Hyun Yong; Choi, Suyong; Gyun, Dooyeon; Hong, Byung-Sik; Jo, Mihee; Kim, Hyunchul; Kim, Tae Jeong; Lee, Kyong Sei; Moon, Dong Ho; Park, Sung Keun; Seo, Eunsung; Choi, Minkyoo; Kang, Seokon; Kim, Hyunyong; Kim, Ji Hyun; Park, Chawon; Park, Inkyu; Park, Sangnam; Ryu, Geonmo; Cho, Yongjin; Choi, Young-Il; Choi, Young Kyu; Goh, Junghwan; Kim, Min Suk; Kwon, Eunhyang; Lee, Byounghoon; Lee, Jongseok; Lee, Sungeun; Seo, Hyunkwan; Yu, Intae; Bilinskas, Mykolas Jurgis; Grigelionis, Ignas; Janulis, Mindaugas; Juodagalvis, Andrius; Castilla-Valdez, Heriberto; De La Cruz-Burelo, Eduard; Heredia-de La Cruz, Ivan; Lopez-Fernandez, Ricardo; Magaña Villalba, Ricardo; Martínez-Ortega, Jorge; Sánchez-Hernández, Alberto; Villasenor-Cendejas, Luis Manuel; Carrillo Moreno, Salvador; Vazquez Valencia, Fabiola; Salazar Ibarguen, Humberto Antonio; Casimiro Linares, Edgar; Morelos Pineda, Antonio; Reyes-Santos, Marco A; Krofcheck, David; Bell, Alan James; Butler, Philip H; Doesburg, Robert; Reucroft, Steve; Silverwood, Hamish; Ahmad, Muhammad; Asghar, Muhammad Irfan; Hoorani, Hafeez R; Khalid, Shoaib; Khan, Wajid Ali; Khurshid, Taimoor; Qazi, Shamona; Shah, Mehar Ali; Shoaib, Muhammad; Brona, Grzegorz; Bunkowski, Karol; Cwiok, Mikolaj; Dominik, Wojciech; Doroba, Krzysztof; Kalinowski, Artur; Konecki, Marcin; Krolikowski, Jan; Bialkowska, Helena; Boimska, Bozena; Frueboes, Tomasz; Gokieli, Ryszard; Górski, Maciej; Kazana, Malgorzata; Nawrocki, Krzysztof; Romanowska-Rybinska, Katarzyna; Szleper, Michal; Wrochna, Grzegorz; Zalewski, Piotr; Almeida, Nuno; Bargassa, Pedrame; David Tinoco Mendes, Andre; Faccioli, Pietro; Ferreira Parracho, Pedro Guilherme; Gallinaro, Michele; Musella, Pasquale; Seixas, Joao; Varela, Joao; Vischia, Pietro; Belotelov, Ivan; Bunin, Pavel; Gavrilenko, Mikhail; Golutvin, Igor; Kamenev, Alexey; Karjavin, Vladimir; Kozlov, Guennady; Lanev, Alexander; Malakhov, Alexander; Moisenz, Petr; Palichik, Vladimir; Perelygin, Victor; Savina, Maria; Shmatov, Sergey; Smirnov, Vitaly; Volodko, Anton; Zarubin, Anatoli; Evstyukhin, Sergey; Golovtsov, Victor; Ivanov, Yury; Kim, Victor; Levchenko, Petr; Murzin, Victor; Oreshkin, Vadim; Smirnov, Igor; Sulimov, Valentin; Uvarov, Lev; Vavilov, Sergey; Vorobyev, Alexey; Vorobyev, Andrey; Andreev, Yuri; Dermenev, Alexander; Gninenko, Sergei; Golubev, Nikolai; Kirsanov, Mikhail; Krasnikov, Nikolai; Matveev, Viktor; Pashenkov, Anatoli; Tlisov, Danila; Toropin, Alexander; Epshteyn, Vladimir; Erofeeva, Maria; Gavrilov, Vladimir; Kossov, Mikhail; Lychkovskaya, Natalia; Popov, Vladimir; Safronov, Grigory; Semenov, Sergey; Stolin, Viatcheslav; Vlasov, Evgueni; Zhokin, Alexander; Belyaev, Andrey; Boos, Edouard; Dubinin, Mikhail; Dudko, Lev; Ershov, Alexander; Gribushin, Andrey; Klyukhin, Vyacheslav; Kodolova, Olga; Lokhtin, Igor; Markina, Anastasia; Obraztsov, Stepan; Perfilov, Maxim; Petrushanko, Sergey; Popov, Andrey; Sarycheva, Ludmila; Savrin, Viktor; Snigirev, Alexander; Andreev, Vladimir; Azarkin, Maksim; Dremin, Igor; Kirakosyan, Martin; Leonidov, Andrey; Mesyats, Gennady; Rusakov, Sergey V; Vinogradov, Alexey; Azhgirey, Igor; Bayshev, Igor; Bitioukov, Sergei; Grishin, Viatcheslav; Kachanov, Vassili; Konstantinov, Dmitri; Korablev, Andrey; Krychkine, Victor; Petrov, Vladimir; Ryutin, Roman; Sobol, Andrei; Tourtchanovitch, Leonid; Troshin, Sergey; Tyurin, Nikolay; Uzunian, Andrey; Volkov, Alexey; Adzic, Petar; Djordjevic, Milos; Ekmedzic, Marko; Krpic, Dragomir; Milosevic, Jovan; Aguilar-Benitez, Manuel; Alcaraz Maestre, Juan; Arce, Pedro; Battilana, Carlo; Calvo, Enrique; Cerrada, Marcos; Chamizo Llatas, Maria; Colino, Nicanor; De La Cruz, Begona; Delgado Peris, Antonio; Diez Pardos, Carmen; Domínguez Vázquez, Daniel; Fernandez Bedoya, Cristina; Fernández Ramos, Juan Pablo; Ferrando, Antonio; Flix, Jose; Fouz, Maria Cruz; Garcia-Abia, Pablo; Gonzalez Lopez, Oscar; Goy Lopez, Silvia; Hernandez, Jose M; Josa, Maria Isabel; Merino, Gonzalo; Puerta Pelayo, Jesus; Redondo, Ignacio; Romero, Luciano; Santaolalla, Javier; Senghi Soares, Mara; Willmott, Carlos; Albajar, Carmen; Codispoti, Giuseppe; de Trocóniz, Jorge F; Cuevas, Javier; Fernandez Menendez, Javier; Folgueras, Santiago; Gonzalez Caballero, Isidro; Lloret Iglesias, Lara; Piedra Gomez, Jonatan; Vizan Garcia, Jesus Manuel; Brochero Cifuentes, Javier Andres; Cabrillo, Iban Jose; Calderon, Alicia; Chuang, Shan-Huei; Duarte Campderros, Jordi; Felcini, Marta; Fernandez, Marcos; Gomez, Gervasio; Gonzalez Sanchez, Javier; Jorda, Clara; Lobelle Pardo, Patricia; Lopez Virto, Amparo; Marco, Jesus; Marco, Rafael; Martinez Rivero, Celso; Matorras, Francisco; Munoz Sanchez, Francisca Javiela; Rodrigo, Teresa; Rodríguez-Marrero, Ana Yaiza; Ruiz-Jimeno, Alberto; Scodellaro, Luca; Sobron Sanudo, Mar; Vila, Ivan; Vilar Cortabitarte, Rocio; Abbaneo, Duccio; Auffray, Etiennette; Auzinger, Georg; Baillon, Paul; Ball, Austin; Barney, David; Bernet, Colin; Bianchi, Giovanni; Bloch, Philippe; Bocci, Andrea; Bonato, Alessio; Breuker, Horst; Camporesi, Tiziano; Cerminara, Gianluca; Christiansen, Tim; Coarasa Perez, Jose Antonio; D'Enterria, David; De Roeck, Albert; Di Guida, Salvatore; Dobson, Marc; Dupont-Sagorin, Niels; Elliott-Peisert, Anna; Frisch, Benjamin; Funk, Wolfgang; Georgiou, Georgios; Giffels, Manuel; Gigi, Dominique; Gill, Karl; Giordano, Domenico; Giunta, Marina; Glege, Frank; Gomez-Reino Garrido, Robert; Govoni, Pietro; Gowdy, Stephen; Guida, Roberto; Hansen, Magnus; Harris, Philip; Hartl, Christian; Harvey, John; Hegner, Benedikt; Hinzmann, Andreas; Innocente, Vincenzo; Janot, Patrick; Kaadze, Ketino; Karavakis, Edward; Kousouris, Konstantinos; Lecoq, Paul; Lenzi, Piergiulio; Lourenco, Carlos; Maki, Tuula; Malberti, Martina; Malgeri, Luca; Mannelli, Marcello; Masetti, Lorenzo; Meijers, Frans; Mersi, Stefano; Meschi, Emilio; Moser, Roland; Mozer, Matthias Ulrich; Mulders, Martijn; Nesvold, Erik; Nguyen, Matthew; Orimoto, Toyoko; Orsini, Luciano; Palencia Cortezon, Enrique; Perez, Emmanuelle; Petrilli, Achille; Pfeiffer, Andreas; Pierini, Maurizio; Pimiä, Martti; Piparo, Danilo; Polese, Giovanni; Quertenmont, Loic; Racz, Attila; Reece, William; Rodrigues Antunes, Joao; Rolandi, Gigi; Rommerskirchen, Tanja; Rovelli, Chiara; Rovere, Marco; Sakulin, Hannes; Santanastasio, Francesco; Schäfer, Christoph; Schwick, Christoph; Segoni, Ilaria; Sekmen, Sezen; Sharma, Archana; Siegrist, Patrice; Silva, Pedro; Simon, Michal; Sphicas, Paraskevas; Spiga, Daniele; Spiropulu, Maria; Stoye, Markus; Tsirou, Andromachi; Veres, Gabor Istvan; Vlimant, Jean-Roch; Wöhri, Hermine Katharina; Worm, Steven; Zeuner, Wolfram Dietrich; Bertl, Willi; Deiters, Konrad; Erdmann, Wolfram; Gabathuler, Kurt; Horisberger, Roland; Ingram, Quentin; Kaestli, Hans-Christian; König, Stefan; Kotlinski, Danek; Langenegger, Urs; Meier, Frank; Renker, Dieter; Rohe, Tilman; Sibille, Jennifer; Bäni, Lukas; Bortignon, Pierluigi; Buchmann, Marco-Andrea; Casal, Bruno; Chanon, Nicolas; Chen, Zhiling; Deisher, Amanda; Dissertori, Günther; Dittmar, Michael; Dünser, Marc; Eugster, Jürg; Freudenreich, Klaus; Grab, Christoph; Lecomte, Pierre; Lustermann, Werner; Marini, Andrea Carlo; Martinez Ruiz del Arbol, Pablo; Mohr, Niklas; Moortgat, Filip; Nägeli, Christoph; Nef, Pascal; Nessi-Tedaldi, Francesca; Pape, Luc; Pauss, Felicitas; Peruzzi, Marco; Ronga, Frederic Jean; Rossini, Marco; Sala, Leonardo; Sanchez, Ann - Karin; Starodumov, Andrei; Stieger, Benjamin; Takahashi, Maiko; Tauscher, Ludwig; Thea, Alessandro; Theofilatos, Konstantinos; Treille, Daniel; Urscheler, Christina; Wallny, Rainer; Weber, Hannsjoerg Artur; Wehrli, Lukas; Aguilo, Ernest; Amsler, Claude; Chiochia, Vincenzo; De Visscher, Simon; Favaro, Carlotta; Ivova Rikova, Mirena; Millan Mejias, Barbara; Otiougova, Polina; Robmann, Peter; Snoek, Hella; Tupputi, Salvatore; Verzetti, Mauro; Chang, Yuan-Hann; Chen, Kuan-Hsin; Go, Apollo; Kuo, Chia-Ming; Li, Syue-Wei; Lin, Willis; Liu, Zong-Kai; Lu, Yun-Ju; Mekterovic, Darko; Singh, Anil; Volpe, Roberta; Yu, Shin-Shan; Bartalini, Paolo; Chang, Paoti; Chang, You-Hao; Chang, Yu-Wei; Chao, Yuan; Chen, Kai-Feng; Dietz, Charles; Grundler, Ulysses; Hou, George Wei-Shu; Hsiung, Yee; Kao, Kai-Yi; Lei, Yeong-Jyi; Lu, Rong-Shyang; Majumder, Devdatta; Petrakou, Eleni; Shi, Xin; Shiu, Jing-Ge; Tzeng, Yeng-Ming; Wang, Minzu; Adiguzel, Aytul; Bakirci, Mustafa Numan; Cerci, Salim; Dozen, Candan; Dumanoglu, Isa; Eskut, Eda; Girgis, Semiray; Gokbulut, Gul; Hos, Ilknur; Kangal, Evrim Ersin; Karapinar, Guler; Kayis Topaksu, Aysel; Onengut, Gulsen; Ozdemir, Kadri; Ozturk, Sertac; Polatoz, Ayse; Sogut, Kenan; Sunar Cerci, Deniz; Tali, Bayram; Topakli, Huseyin; Vergili, Latife Nukhet; Vergili, Mehmet; Akin, Ilina Vasileva; Aliev, Takhmasib; Bilin, Bugra; Bilmis, Selcuk; Deniz, Muhammed; Gamsizkan, Halil; Guler, Ali Murat; Ocalan, Kadir; Ozpineci, Altug; Serin, Meltem; Sever, Ramazan; Surat, Ugur Emrah; Yalvac, Metin; Yildirim, Eda; Zeyrek, Mehmet; Deliomeroglu, Mehmet; Gülmez, Erhan; Isildak, Bora; Kaya, Mithat; Kaya, Ozlem; Ozkorucuklu, Suat; Sonmez, Nasuf; Cankocak, Kerem; Levchuk, Leonid; Bostock, Francis; Brooke, James John; Clement, Emyr; Cussans, David; Flacher, Henning; Frazier, Robert; Goldstein, Joel; Grimes, Mark; Heath, Greg P; Heath, Helen F; Kreczko, Lukasz; Metson, Simon; Newbold, Dave M; Nirunpong, Kachanon; Poll, Anthony; Senkin, Sergey; Smith, Vincent J; Williams, Thomas; Basso, Lorenzo; Bell, Ken W; Belyaev, Alexander; Brew, Christopher; Brown, Robert M; Cockerill, David JA; Coughlan, John A; Harder, Kristian; Harper, Sam; Jackson, James; Kennedy, Bruce W; Olaiya, Emmanuel; Petyt, David; Radburn-Smith, Benjamin Charles; Shepherd-Themistocleous, Claire; Tomalin, Ian R; Womersley, William John; Bainbridge, Robert; Ball, Gordon; Beuselinck, Raymond; Buchmuller, Oliver; Colling, David; Cripps, Nicholas; Cutajar, Michael; Dauncey, Paul; Davies, Gavin; Della Negra, Michel; Ferguson, William; Fulcher, Jonathan; Futyan, David; Gilbert, Andrew; Guneratne Bryer, Arlo; Hall, Geoffrey; Hatherell, Zoe; Hays, Jonathan; Iles, Gregory; Jarvis, Martyn; Karapostoli, Georgia; Lyons, Louis; Magnan, Anne-Marie; Marrouche, Jad; Mathias, Bryn; Nandi, Robin; Nash, Jordan; Nikitenko, Alexander; Papageorgiou, Anastasios; Pela, Joao; Pesaresi, Mark; Petridis, Konstantinos; Pioppi, Michele; Raymond, David Mark; Rogerson, Samuel; Rompotis, Nikolaos; Rose, Andrew; Ryan, Matthew John; Seez, Christopher; Sharp, Peter; Sparrow, Alex; Tapper, Alexander; Vazquez Acosta, Monica; Virdee, Tejinder; Wakefield, Stuart; Wardle, Nicholas; Whyntie, Tom; Barrett, Matthew; Chadwick, Matthew; Cole, Joanne; Hobson, Peter R; Khan, Akram; Kyberd, Paul; Leggat, Duncan; Leslie, Dawn; Martin, William; Reid, Ivan; Symonds, Philip; Teodorescu, Liliana; Turner, Mark; Hatakeyama, Kenichi; Liu, Hongxuan; Scarborough, Tara; Henderson, Conor; Rumerio, Paolo; Avetisyan, Aram; Bose, Tulika; Fantasia, Cory; Heister, Arno; St John, Jason; Lawson, Philip; Lazic, Dragoslav; Rohlf, James; Sperka, David; Sulak, Lawrence; Alimena, Juliette; Bhattacharya, Saptaparna; Cutts, David; Ferapontov, Alexey; Heintz, Ulrich; Jabeen, Shabnam; Kukartsev, Gennadiy; Landsberg, Greg; Luk, Michael; Narain, Meenakshi; Nguyen, Duong; Segala, Michael; Sinthuprasith, Tutanon; Speer, Thomas; Tsang, Ka Vang; Breedon, Richard; Breto, Guillermo; Calderon De La Barca Sanchez, Manuel; Chauhan, Sushil; Chertok, Maxwell; Conway, John; Conway, Rylan; Cox, Peter Timothy; Dolen, James; Erbacher, Robin; Gardner, Michael; Houtz, Rachel; Ko, Winston; Kopecky, Alexandra; Lander, Richard; Mall, Orpheus; Miceli, Tia; Nelson, Randy; Pellett, Dave; Rutherford, Britney; Searle, Matthew; Smith, John; Squires, Michael; Tripathi, Mani; Vasquez Sierra, Ricardo; Andreev, Valeri; Cline, David; Cousins, Robert; Duris, Joseph; Erhan, Samim; Everaerts, Pieter; Farrell, Chris; Hauser, Jay; Ignatenko, Mikhail; Plager, Charles; Rakness, Gregory; Schlein, Peter; Tucker, Jordan; Valuev, Vyacheslav; Weber, Matthias; Babb, John; Clare, Robert; Dinardo, Mauro Emanuele; Ellison, John Anthony; Gary, J William; Giordano, Ferdinando; Hanson, Gail; Jeng, Geng-Yuan; Liu, Hongliang; Long, Owen Rosser; Luthra, Arun; Nguyen, Harold; Paramesvaran, Sudarshan; Sturdy, Jared; Sumowidagdo, Suharyo; Wilken, Rachel; Wimpenny, Stephen; Andrews, Warren; Branson, James G; Cerati, Giuseppe Benedetto; Cittolin, Sergio; Evans, David; Golf, Frank; Holzner, André; Kelley, Ryan; Lebourgeois, Matthew; Letts, James; Macneill, Ian; Mangano, Boris; Muelmenstaedt, Johannes; Padhi, Sanjay; Palmer, Christopher; Petrucciani, Giovanni; Pieri, Marco; Ranieri, Riccardo; Sani, Matteo; Sharma, Vivek; Simon, Sean; Sudano, Elizabeth; Tadel, Matevz; Tu, Yanjun; Vartak, Adish; Wasserbaech, Steven; Würthwein, Frank; Yagil, Avraham; Yoo, Jaehyeok; Barge, Derek; Bellan, Riccardo; Campagnari, Claudio; D'Alfonso, Mariarosaria; Danielson, Thomas; Flowers, Kristen; Geffert, Paul; Incandela, Joe; Justus, Christopher; Kalavase, Puneeth; Koay, Sue Ann; Kovalskyi, Dmytro; Krutelyov, Vyacheslav; Lowette, Steven; Mccoll, Nickolas; Pavlunin, Viktor; Rebassoo, Finn; Ribnik, Jacob; Richman, Jeffrey; Rossin, Roberto; Stuart, David; To, Wing; West, Christopher; Apresyan, Artur; Bornheim, Adolf; Chen, Yi; Di Marco, Emanuele; Duarte, Javier; Gataullin, Marat; Ma, Yousi; Mott, Alexander; Newman, Harvey B; Rogan, Christopher; Timciuc, Vladlen; Traczyk, Piotr; Veverka, Jan; Wilkinson, Richard; Yang, Yong; Zhu, Ren-Yuan; Akgun, Bora; Carroll, Ryan; Ferguson, Thomas; Iiyama, Yutaro; Jang, Dong Wook; Liu, Yueh-Feng; Paulini, Manfred; Vogel, Helmut; Vorobiev, Igor; Cumalat, John Perry; Drell, Brian Robert; Edelmaier, Christopher; Ford, William T; Gaz, Alessandro; Heyburn, Bernadette; Luiggi Lopez, Eduardo; Smith, James; Stenson, Kevin; Ulmer, Keith; Wagner, Stephen Robert; Agostino, Lorenzo; Alexander, James; Chatterjee, Avishek; Eggert, Nicholas; Gibbons, Lawrence Kent; Heltsley, Brian; Hopkins, Walter; Khukhunaishvili, Aleko; Kreis, Benjamin; Mirman, Nathan; Nicolas Kaufman, Gala; Patterson, Juliet Ritchie; Ryd, Anders; Salvati, Emmanuele; Sun, Werner; Teo, Wee Don; Thom, Julia; Thompson, Joshua; Vaughan, Jennifer; Weng, Yao; Winstrom, Lucas; Wittich, Peter; Winn, Dave; Abdullin, Salavat; Albrow, Michael; Anderson, Jacob; Bauerdick, Lothar AT; Beretvas, Andrew; Berryhill, Jeffrey; Bhat, Pushpalatha C; Bloch, Ingo; Burkett, Kevin; Butler, Joel Nathan; Chetluru, Vasundhara; Cheung, Harry; Chlebana, Frank; Elvira, Victor Daniel; Fisk, Ian; Freeman, Jim; Gao, Yanyan; Green, Dan; Gutsche, Oliver; Hahn, Alan; Hanlon, Jim; Harris, Robert M; Hirschauer, James; Hooberman, Benjamin; Jindariani, Sergo; Johnson, Marvin; Joshi, Umesh; Kilminster, Benjamin; Klima, Boaz; Kunori, Shuichi; Kwan, Simon; Lincoln, Don; Lipton, Ron; Lueking, Lee; Lykken, Joseph; Maeshima, Kaori; Marraffino, John Michael; Maruyama, Sho; Mason, David; McBride, Patricia; Mishra, Kalanand; Mrenna, Stephen; Musienko, Yuri; Newman-Holmes, Catherine; O'Dell, Vivian; Prokofyev, Oleg; Sexton-Kennedy, Elizabeth; Sharma, Seema; Spalding, William J; Spiegel, Leonard; Tan, Ping; Taylor, Lucas; Tkaczyk, Slawek; Tran, Nhan Viet; Uplegger, Lorenzo; Vaandering, Eric Wayne; Vidal, Richard; Whitmore, Juliana; Wu, Weimin; Yang, Fan; Yumiceva, Francisco; Yun, Jae Chul; Acosta, Darin; Avery, Paul; Bourilkov, Dimitri; Chen, Mingshui; Das, Souvik; De Gruttola, Michele; Di Giovanni, Gian Piero; Dobur, Didar; Drozdetskiy, Alexey; Field, Richard D; Fisher, Matthew; Fu, Yu; Furic, Ivan-Kresimir; Gartner, Joseph; Hugon, Justin; Kim, Bockjoo; Konigsberg, Jacobo; Korytov, Andrey; Kropivnitskaya, Anna; Kypreos, Theodore; Low, Jia Fu; Matchev, Konstantin; Milenovic, Predrag; Mitselmakher, Guenakh; Muniz, Lana; Remington, Ronald; Rinkevicius, Aurelijus; Sellers, Paul; Skhirtladze, Nikoloz; Snowball, Matthew; Yelton, John; Zakaria, Mohammed; Gaultney, Vanessa; Lebolo, Luis Miguel; Linn, Stephan; Markowitz, Pete; Martinez, German; Rodriguez, Jorge Luis; Adams, Todd; Askew, Andrew; Bochenek, Joseph; Chen, Jie; Diamond, Brendan; Gleyzer, Sergei V; Haas, Jeff; Hagopian, Sharon; Hagopian, Vasken; Jenkins, Merrill; Johnson, Kurtis F; Prosper, Harrison; Veeraraghavan, Venkatesh; Weinberg, Marc; Baarmand, Marc M; Dorney, Brian; Hohlmann, Marcus; Kalakhety, Himali; Vodopiyanov, Igor; Adams, Mark Raymond; Anghel, Ioana Maria; Apanasevich, Leonard; Bai, Yuting; Bazterra, Victor Eduardo; Betts, Russell Richard; Callner, Jeremy; Cavanaugh, Richard; Dragoiu, Cosmin; Evdokimov, Olga; Garcia-Solis, Edmundo Javier; Gauthier, Lucie; Gerber, Cecilia Elena; Hofman, David Jonathan; Khalatyan, Samvel; Lacroix, Florent; Malek, Magdalena; O'Brien, Christine; Silkworth, Christopher; Strom, Derek; Varelas, Nikos; Akgun, Ugur; Albayrak, Elif Asli; Bilki, Burak; Chung, Kwangzoo; Clarida, Warren; Duru, Firdevs; Griffiths, Scott; Lae, Chung Khim; Merlo, Jean-Pierre; Mermerkaya, Hamit; Mestvirishvili, Alexi; Moeller, Anthony; Nachtman, Jane; Newsom, Charles Ray; Norbeck, Edwin; Olson, Jonathan; Onel, Yasar; Ozok, Ferhat; Sen, Sercan; Tiras, Emrah; Wetzel, James; Yetkin, Taylan; Yi, Kai; Barnett, Bruce Arnold; Blumenfeld, Barry; Bolognesi, Sara; Fehling, David; Giurgiu, Gavril; Gritsan, Andrei; Guo, Zijin; Hu, Guofan; Maksimovic, Petar; Rappoccio, Salvatore; Swartz, Morris; Whitbeck, Andrew; Baringer, Philip; Bean, Alice; Benelli, Gabriele; Grachov, Oleg; Kenny Iii, Raymond Patrick; Murray, Michael; Noonan, Daniel; Radicci, Valeria; Sanders, Stephen; Stringer, Robert; Tinti, Gemma; Wood, Jeffrey Scott; Zhukova, Victoria; Barfuss, Anne-Fleur; Bolton, Tim; Chakaberia, Irakli; Ivanov, Andrew; Khalil, Sadia; Makouski, Mikhail; Maravin, Yurii; Shrestha, Shruti; Svintradze, Irakli; Gronberg, Jeffrey; Lange, David; Wright, Douglas; Baden, Drew; Boutemeur, Madjid; Calvert, Brian; Eno, Sarah Catherine; Gomez, Jaime; Hadley, Nicholas John; Kellogg, Richard G; Kirn, Malina; Kolberg, Ted; Lu, Ying; Marionneau, Matthieu; Mignerey, Alice; Peterman, Alison; Rossato, Kenneth; Skuja, Andris; Temple, Jeffrey; Tonjes, Marguerite; Tonwar, Suresh C; Twedt, Elizabeth; Bauer, Gerry; Bendavid, Joshua; Busza, Wit; Butz, Erik; Cali, Ivan Amos; Chan, Matthew; Dutta, Valentina; Gomez Ceballos, Guillelmo; Goncharov, Maxim; Hahn, Kristan Allan; Kim, Yongsun; Klute, Markus; Lee, Yen-Jie; Li, Wei; Luckey, Paul David; Ma, Teng; Nahn, Steve; Paus, Christoph; Ralph, Duncan; Roland, Christof; Roland, Gunther; Rudolph, Matthew; Stephans, George; Stöckli, Fabian; Sumorok, Konstanty; Sung, Kevin; Velicanu, Dragos; Wenger, Edward Allen; Wolf, Roger; Wyslouch, Bolek; Xie, Si; Yang, Mingming; Yilmaz, Yetkin; Yoon, Sungho; Zanetti, Marco; Cooper, Seth; Cushman, Priscilla; Dahmes, Bryan; De Benedetti, Abraham; Franzoni, Giovanni; Gude, Alexander; Haupt, Jason; Kao, Shih-Chuan; Klapoetke, Kevin; Kubota, Yuichi; Mans, Jeremy; Pastika, Nathaniel; Rusack, Roger; Sasseville, Michael; Singovsky, Alexander; Tambe, Norbert; Turkewitz, Jared; Cremaldi, Lucien Marcus; Kroeger, Rob; Perera, Lalith; Rahmat, Rahmat; Sanders, David A; Avdeeva, Ekaterina; Bloom, Kenneth; Bose, Suvadeep; Butt, Jamila; Claes, Daniel R; Dominguez, Aaron; Eads, Michael; Jindal, Pratima; Keller, Jason; Kravchenko, Ilya; Lazo-Flores, Jose; Malbouisson, Helena; Malik, Sudhir; Snow, Gregory R; Baur, Ulrich; Godshalk, Andrew; Iashvili, Ia; Jain, Supriya; Kharchilava, Avto; Kumar, Ashish; Shipkowski, Simon Peter; Smith, Kenneth; Alverson, George; Barberis, Emanuela; Baumgartel, Darin; Chasco, Matthew; Haley, Joseph; Trocino, Daniele; Wood, Darien; Zhang, Jinzhong; Anastassov, Anton; Kubik, Andrew; Mucia, Nicholas; Odell, Nathaniel; Ofierzynski, Radoslaw Adrian; Pollack, Brian; Pozdnyakov, Andrey; Schmitt, Michael Henry; Stoynev, Stoyan; Velasco, Mayda; Won, Steven; Antonelli, Louis; Berry, Douglas; Brinkerhoff, Andrew; Hildreth, Michael; Jessop, Colin; Karmgard, Daniel John; Kolb, Jeff; Lannon, Kevin; Luo, Wuming; Lynch, Sean; Marinelli, Nancy; Morse, David Michael; Pearson, Tessa; Ruchti, Randy; Slaunwhite, Jason; Valls, Nil; Warchol, Jadwiga; Wayne, Mitchell; Wolf, Matthias; Ziegler, Jill; Bylsma, Ben; Durkin, Lloyd Stanley; Hill, Christopher; Hughes, Richard; Killewald, Phillip; Kotov, Khristian; Ling, Ta-Yung; Puigh, Darren; Rodenburg, Marissa; Vuosalo, Carl; Williams, Grayson; Winer, Brian L; Adam, Nadia; Berry, Edmund; Elmer, Peter; Gerbaudo, Davide; Halyo, Valerie; Hebda, Philip; Hegeman, Jeroen; Hunt, Adam; Laird, Edward; Lopes Pegna, David; Lujan, Paul; Marlow, Daniel; Medvedeva, Tatiana; Mooney, Michael; Olsen, James; Piroué, Pierre; Quan, Xiaohang; Raval, Amita; Saka, Halil; Stickland, David; Tully, Christopher; Werner, Jeremy Scott; Zuranski, Andrzej; Acosta, Jhon Gabriel; Brownson, Eric; Huang, Xing Tao; Lopez, Angel; Mendez, Hector; Oliveros, Sandra; Ramirez Vargas, Juan Eduardo; Zatserklyaniy, Andriy; Alagoz, Enver; Barnes, Virgil E; Benedetti, Daniele; Bolla, Gino; Bortoletto, Daniela; De Mattia, Marco; Everett, Adam; Hu, Zhen; Jones, Matthew; Koybasi, Ozhan; Kress, Matthew; Laasanen, Alvin T; Leonardo, Nuno; Maroussov, Vassili; Merkel, Petra; Miller, David Harry; Neumeister, Norbert; Shipsey, Ian; Silvers, David; Svyatkovskiy, Alexey; Vidal Marono, Miguel; Yoo, Hwi Dong; Zablocki, Jakub; Zheng, Yu; Guragain, Samir; Parashar, Neeti; Adair, Antony; Boulahouache, Chaouki; Cuplov, Vesna; Ecklund, Karl Matthew; Geurts, Frank JM; Padley, Brian Paul; Redjimi, Radia; Roberts, Jay; Zabel, James; Betchart, Burton; Bodek, Arie; Chung, Yeon Sei; Covarelli, Roberto; de Barbaro, Pawel; Demina, Regina; Eshaq, Yossof; Garcia-Bellido, Aran; Goldenzweig, Pablo; Gotra, Yury; Han, Jiyeon; Harel, Amnon; Korjenevski, Sergey; Miner, Daniel Carl; Vishnevskiy, Dmitry; Zielinski, Marek; Bhatti, Anwar; Ciesielski, Robert; Demortier, Luc; Goulianos, Konstantin; Lungu, Gheorghe; Malik, Sarah; Mesropian, Christina; Arora, Sanjay; Barker, Anthony; Chou, John Paul; Contreras-Campana, Christian; Contreras-Campana, Emmanuel; Duggan, Daniel; Ferencek, Dinko; Gershtein, Yuri; Gray, Richard; Halkiadakis, Eva; Hidas, Dean; Hits, Dmitry; Lath, Amitabh; Panwalkar, Shruti; Park, Michael; Patel, Rishi; Rekovic, Vladimir; Richards, Alan; Robles, Jorge; Rose, Keith; Salur, Sevil; Schnetzer, Steve; Seitz, Claudia; Somalwar, Sunil; Stone, Robert; Thomas, Scott; Cerizza, Giordano; Hollingsworth, Matthew; Spanier, Stefan; Yang, Zong-Chang; York, Andrew; Eusebi, Ricardo; Flanagan, Will; Gilmore, Jason; Kamon, Teruki; Khotilovich, Vadim; Montalvo, Roy; Osipenkov, Ilya; Pakhotin, Yuriy; Perloff, Alexx; Roe, Jeffrey; Safonov, Alexei; Sakuma, Tai; Sengupta, Sinjini; Suarez, Indara; Tatarinov, Aysen; Toback, David; Akchurin, Nural; Damgov, Jordan; Dudero, Phillip Russell; Jeong, Chiyoung; Kovitanggoon, Kittikul; Lee, Sung Won; Libeiro, Terence; Roh, Youn; Volobouev, Igor; Appelt, Eric; Engh, Daniel; Florez, Carlos; Greene, Senta; Gurrola, Alfredo; Johns, Willard; Kurt, Pelin; Maguire, Charles; Melo, Andrew; Sheldon, Paul; Snook, Benjamin; Tuo, Shengquan; Velkovska, Julia; Arenton, Michael Wayne; Balazs, Michael; Boutle, Sarah; Cox, Bradley; Francis, Brian; Goodell, Joseph; Hirosky, Robert; Ledovskoy, Alexander; Lin, Chuanzhe; Neu, Christopher; Wood, John; Yohay, Rachel; Gollapinni, Sowjanya; Harr, Robert; Karchin, Paul Edmund; Kottachchi Kankanamge Don, Chamath; Lamichhane, Pramod; Sakharov, Alexandre; Anderson, Michael; Bachtis, Michail; Belknap, Donald; Borrello, Laura; Carlsmith, Duncan; Cepeda, Maria; Dasu, Sridhara; Gray, Lindsey; Grogg, Kira Suzanne; Grothe, Monika; Hall-Wilton, Richard; Herndon, Matthew; Hervé, Alain; Klabbers, Pamela; Klukas, Jeffrey; Lanaro, Armando; Lazaridis, Christos; Leonard, Jessica; Loveless, Richard; Mohapatra, Ajit; Ojalvo, Isabel; Pierro, Giuseppe Antonio; Ross, Ian; Savin, Alexander; Smith, Wesley H; Swanson, Joshua

    2013-07-16

    The result of a search for heavy long-lived charged particles produced in pp collisions at $\\sqrt{s}$ = 7 TeV at the LHC is described. The data sample has been collected using the CMS detector and corresponds to an integrated luminosity of 5.0 inverse femtobarns. The inner tracking detectors are used to define a sample of events containing tracks with high momentum and high ionization energy loss. A second sample of events with high-momentum and high-ionization tracks satisfying muon identification and long time-of-flight criteria is analyzed independently. In both cases, the results are consistent with the expected background estimated from data. The results are used to establish cross section limits as a function of mass within the context of models with long-lived gluinos, scalar top quarks and scalar taus. Cross section limits on hyper-meson particles, containing new elementary long-lived hyper-quarks predicted by a vector-like confinement model, are also presented. Lower limits at 95% confidence level on...

  13. Stereotactic Image-Guided Intensity Modulated Radiotherapy Using the HI-ART II Helical Tomotherapy System

    International Nuclear Information System (INIS)

    Holmes, Timothy W.; Hudes, Richard; Dziuba, Sylwester; Kazi, Abdul; Hall, Mark; Dawson, Dana

    2008-01-01

    The highly integrated adaptive radiation therapy (HI-ART II) helical tomotherapy unit is a new radiotherapy machine designed to achieve highly precise and accurate treatments at all body sites. The precision and accuracy of the HI-ART II is similar to that provided by stereotactic radiosurgery systems, hence the historical distinction between external beam radiotherapy and stereotactic procedures based on differing precision requirements is removed for this device. The objectives of this work are: (1) to describe stereotactic helical tomotherapy processes (SRS, SBRT); (2) to show that the precision and accuracy of the HI-ART meet the requirements defined for SRS and SBRT; and (3) to describe the clinical implementation of a stereotactic image-guided intensity modulated radiation therapy (IG-IMRT) system that incorporates optical motion management

  14. Heavy ion therapy: Bevalac epoch

    International Nuclear Information System (INIS)

    Castro, J.R.

    1993-10-01

    An overview of heavy ion therapy at the Bevelac complex (SuperHILac linear accelerator + Bevatron) is given. Treatment planning, clinical results with helium ions on the skull base and uveal melanoma, clinical results with high-LET charged particles, neon radiotherapy of prostate cancer, heavy charged particle irradiation for unfavorable soft tissue sarcoma, preliminary results in heavy charged particle irradiation of bone sarcoma, and irradiation of bile duct carcinoma with charged particles and-or photons are all covered

  15. SU-F-T-593: Technical Treatment Accuracy in a Clinic of Fractionated Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Bisht, R; Kale, S; Natanasabapathi, G; Singh, M; Agarwal, D; Rath, G; Julka, P; Kumar, P; Thulkar, S; Garg, A; Sharma, B [All India Institute of Medical Sciences, Delhi, Delhi (India)

    2016-06-15

    Purpose: The purpose of this study is to estimate technical treatment accuracy in fractionated stereotactic radiosurgery (fSRS) using extend system (ES) of Gamma Knife (GK). Methods: The fSRS with GK relies on a patient specific re-locatable immobilization system. The reference treatment position is estimated using a digital probe and a repositioning check tool (RCT). The “calibration values” of RCT apertures were compared with measured values on RCT-QA tool to evaluate the standard error (SE) associated with RCT measurements. A treatment plan with single “4 mm collimator shot” was created to deliver a radiation dose of 5 Gy at the predefined plane of a newly designed in-house head-neck phantom. The plan was investigated using radiochromic EBT3 films. The stereotactic CT imaging of a designed mini CT phantom and distortion study of MR imaging, were combined to calculate imaging SE. The focal precision check for GK machine tolerance was performed using a central diode test tool. Results: Twenty observations of RCT and digital probe, shown the SE of +/−0.0186mm and +/−0.0002mm respectively. A mean positional shift of 0.2752mm (σ=0.0696mm) was observed for twenty similar treatment settings of head-neck phantom. The difference between radiological and predefined exposure point was 0.4650mm and 0.4270mm; for two independent experiments. The imaging studies showed a combined SE of +/− 0.1055mm. Twenty frequent runs of a diode test tool showed the tolerance SE of +/−0.0096mm. If, the measurements are considered to be at 95% of confidence level, an expanded uncertainty was evaluated as +/− 0.2371mm with our system. The positional shift, when combined with an expanded uncertainty, a trivial variation of 0.07mm (max) was observed in comparing resultant radiological precision through film investigations. Conclusion: The study proposes an expression of “technical treatment accuracy” within “known uncertainties” is rational in the estimation of

  16. Current signal of silicon detectors facing charged particles and heavy ions; Reponse en courant des detecteurs silicium aux particules chargees et aux ions lourds

    Energy Technology Data Exchange (ETDEWEB)

    Hamrita, H

    2005-07-01

    This work consisted in collecting and studying for the first time the shapes of current signals obtained from charged particles or heavy ions produced by silicon detectors. The document is divided into two main parts. The first consisted in reducing the experimental data obtained with charged particles as well as with heavy ions. These experiments were performed at the Orsay Tandem and at GANIL using LISE. These two experiments enabled us to create a data base formed of current signals with various shapes and various times of collection. The second part consisted in carrying out a simulation of the current signals obtained from the various ions. To obtain this simulation we propose a new model describing the formation of the signal. We used the data base of the signals obtained in experiments in order to constrain the three parameters of our model. In this model, the charge carriers created are regarded as dipoles and their density is related to the dielectric polarization in the silicon detector. This phenomenon induces an increase in permittivity throughout the range of the incident ion and consequently the electric field between the electrodes of the detector is decreased inside the trace. We coupled with this phenomenon a dissociation and extraction mode of the charge carriers so that they can be moved in the electric field. (author)

  17. Spine radiosurgery for the local treatment of spine metastases: Intensity-modulated radiotherapy, image guidance, clinical aspects and future directions

    International Nuclear Information System (INIS)

    Moraes, Fabio Ynoe de; Neves-Junior, Wellington Furtado Pimenta; Hanna, Samir Abdallah; Carvalho, Heloisa de Andrade; Laufer, Ilya

    2016-01-01

    Many cancer patients will develop spinal metastases. Local control is important for preventing neurologic compromise and to relieve pain. Stereotactic body radiotherapy or spinal radiosurgery is a new radiation therapy technique for spinal metastasis that can deliver a high dose of radiation to a tumor while minimizing the radiation delivered to healthy, neighboring tissues. This treatment is based on intensity-modulated radiotherapy, image guidance and rigid immobilization. Spinal radiosurgery is an increasingly utilized treatment method that improves local control and pain relief after delivering ablative doses of radiation. Here, we present a review highlighting the use of spinal radiosurgery for the treatment of metastatic tumors of the spine. The data used in the review were collected from both published studies and ongoing trials. We found that spinal radiosurgery is safe and provides excellent tumor control (up to 94% local control) and pain relief (up to 96%), independent of histology. Extensive data regarding clinical outcomes are available; however, this information has primarily been generated from retrospective and non randomized prospective series. Currently, two randomized trials are enrolling patients to study clinical applications of fractionation schedules spinal Radiosurgery. Additionally, a phase I clinical trial is being conducted to assess the safety of concurrent stereotactic body radiotherapy and ipilimumab for spinal metastases. Clinical trials to refine clinical indications and dose fractionation are ongoing. The concomitant use of targeted agents may produce better outcomes in the future. (author)

  18. Spine radiosurgery for the local treatment of spine metastases: Intensity-modulated radiotherapy, image guidance, clinical aspects and future directions

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Fabio Ynoe de; Neves-Junior, Wellington Furtado Pimenta; Hanna, Samir Abdallah; Carvalho, Heloisa de Andrade [Hospital Sirio-Libanes, Sao Paulo, SP (Brazil). Departamento de Radioterapia; Taunk, Neil Kanth; Yamada, Yoshiya [Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, New York, NY (United States); Laufer, Ilya, E-mail: fymoraes@gmail.com [Memorial Sloan Kettering Cancer Center, Department of Neurosurgery, New York, NY (United States)

    2016-02-15

    Many cancer patients will develop spinal metastases. Local control is important for preventing neurologic compromise and to relieve pain. Stereotactic body radiotherapy or spinal radiosurgery is a new radiation therapy technique for spinal metastasis that can deliver a high dose of radiation to a tumor while minimizing the radiation delivered to healthy, neighboring tissues. This treatment is based on intensity-modulated radiotherapy, image guidance and rigid immobilization. Spinal radiosurgery is an increasingly utilized treatment method that improves local control and pain relief after delivering ablative doses of radiation. Here, we present a review highlighting the use of spinal radiosurgery for the treatment of metastatic tumors of the spine. The data used in the review were collected from both published studies and ongoing trials. We found that spinal radiosurgery is safe and provides excellent tumor control (up to 94% local control) and pain relief (up to 96%), independent of histology. Extensive data regarding clinical outcomes are available; however, this information has primarily been generated from retrospective and non randomized prospective series. Currently, two randomized trials are enrolling patients to study clinical applications of fractionation schedules spinal Radiosurgery. Additionally, a phase I clinical trial is being conducted to assess the safety of concurrent stereotactic body radiotherapy and ipilimumab for spinal metastases. Clinical trials to refine clinical indications and dose fractionation are ongoing. The concomitant use of targeted agents may produce better outcomes in the future. (author)

  19. Large Acceptance Measurement of Photons and Charged Particles in Heavy Ion Reactions

    CERN Multimedia

    2002-01-01

    % WA98 \\\\ \\\\ The aim of the experiment is the high statistics study of photons and neutral hadrons, as well as of charged particles, and their correlations in Pb~-~Pb collisions. The photons are measured by: \\begin{enumerate}[-] \\item a 10~000 module LEADGLASS SPECTROMETER yielding high precision data on $ \\pi ^0 $ and $ \\eta $ at midrapidity (with transverse momenta 0.3 GeV/c $>$ p$ _{T} $ $>$ 4.5 GeV/c for $\\pi ^0 $ and 1.5~GeV/c~$>$~p$ _{T}~$ $>$~4.0~GeV/c for $ \\eta $ covering the $^{\\prime\\prime}$thermal$^{\\prime\\prime}$ as well as the $^{\\prime\\prime}$hard scattering$^{\\prime\\prime}$ regime beyond 3~GeV/c) and determination of the thermal and direct photon to $ \\pi ^0 $ ratio. \\item a pad preshower PHOTON MULTIPLICITY DETECTOR which, by comparing with the charged particle multiplicity measurement allows to determine the photon enrichment in an event or event class. \\end{enumerate}\\\\ \\\\The charged particle setup contains:\\\\ \\\\\\begin{enumerate}[-] \\item a 4000 element SILICON PAD DETECTOR and a 4-inch SIL...

  20. INTER- AND INTRAFRACTION MOTION FOR STEREOTACTIC RADIOSURGERY IN DOGS AND CATS USING A MODIFIED BRAINLAB FRAMELESS STEREOTACTIC MASK SYSTEM.

    Science.gov (United States)

    Dieterich, Sonja; Zwingenberger, Allison; Hansen, Katherine; Pfeiffer, Isabella; Théon, Alain; Kent, Michael S

    2015-01-01

    Precise and accurate patient positioning is necessary when doing stereotactic radiosurgery (SRS) to ensure adequate dosing to the tumor and sparing of normal tissues. This prospective cross-sectional study aimed to assess feasibility of a commercially available modified frameless SRS positioning system for use in veterinary radiotherapy patients with brain tumors. Fifty-one dogs and 12 cats were enrolled. Baseline and verification CT images were acquired. The verification CT images from 32 dogs and five cats had sufficient images for fusion to baseline CT images. A rigid box-based fusion was performed to determine interfraction motion. Forty-eight dogs and 11 cats were assessed for intrafraction motion by cine CT. Seventy percent of dogs and 60% of cats had interfraction 3D vector translational shifts >1 mm, with mean values of 1.9 mm in dogs, and 1.8 mm in cats. In dogs muscle wasting was weakly correlated with translational shifts. The maximum angular interfraction motion observed was 6.3° (roll), 3.5° (pitch), and 3.3° (yaw). There was no correlation between angular interfraction motion and weight, brachycephaly, or muscle wasting. Fifty-seven percent of dogs and 50% of cats had respiration-related intrafraction motion. Of these, 4.5% of dogs and 10% of cats had intrafraction motion >1 mm. This study demonstrates the modified Brainlab system is feasible for SRS in dogs and cats. The smaller cranial size and difference in anatomy increases setup uncertainty in some animals beyond limits usually accepted in SRS. Image-guided positioning is recommended to achieve clinically acceptable setup accuracy (<1 mm) for SRS. © 2015 American College of Veterinary Radiology.

  1. Robotic real-time translational and rotational head motion correction during frameless stereotactic radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xinmin; Belcher, Andrew H.; Grelewicz, Zachary; Wiersma, Rodney D., E-mail: rwiersma@uchicago.edu [Department of Radiation and Cellular Oncology, The University of Chicago, Chicago, Illinois 60637 (United States)

    2015-06-15

    Purpose: To develop a control system to correct both translational and rotational head motion deviations in real-time during frameless stereotactic radiosurgery (SRS). Methods: A novel feedback control with a feed-forward algorithm was utilized to correct for the coupling of translation and rotation present in serial kinematic robotic systems. Input parameters for the algorithm include the real-time 6DOF target position, the frame pitch pivot point to target distance constant, and the translational and angular Linac beam off (gating) tolerance constants for patient safety. Testing of the algorithm was done using a 4D (XY Z + pitch) robotic stage, an infrared head position sensing unit and a control computer. The measured head position signal was processed and a resulting command was sent to the interface of a four-axis motor controller, through which four stepper motors were driven to perform motion compensation. Results: The control of the translation of a brain target was decoupled with the control of the rotation. For a phantom study, the corrected position was within a translational displacement of 0.35 mm and a pitch displacement of 0.15° 100% of the time. For a volunteer study, the corrected position was within displacements of 0.4 mm and 0.2° over 98.5% of the time, while it was 10.7% without correction. Conclusions: The authors report a control design approach for both translational and rotational head motion correction. The experiments demonstrated that control performance of the 4D robotic stage meets the submillimeter and subdegree accuracy required by SRS.

  2. Robotic real-time translational and rotational head motion correction during frameless stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Liu, Xinmin; Belcher, Andrew H.; Grelewicz, Zachary; Wiersma, Rodney D.

    2015-01-01

    Purpose: To develop a control system to correct both translational and rotational head motion deviations in real-time during frameless stereotactic radiosurgery (SRS). Methods: A novel feedback control with a feed-forward algorithm was utilized to correct for the coupling of translation and rotation present in serial kinematic robotic systems. Input parameters for the algorithm include the real-time 6DOF target position, the frame pitch pivot point to target distance constant, and the translational and angular Linac beam off (gating) tolerance constants for patient safety. Testing of the algorithm was done using a 4D (XY Z + pitch) robotic stage, an infrared head position sensing unit and a control computer. The measured head position signal was processed and a resulting command was sent to the interface of a four-axis motor controller, through which four stepper motors were driven to perform motion compensation. Results: The control of the translation of a brain target was decoupled with the control of the rotation. For a phantom study, the corrected position was within a translational displacement of 0.35 mm and a pitch displacement of 0.15° 100% of the time. For a volunteer study, the corrected position was within displacements of 0.4 mm and 0.2° over 98.5% of the time, while it was 10.7% without correction. Conclusions: The authors report a control design approach for both translational and rotational head motion correction. The experiments demonstrated that control performance of the 4D robotic stage meets the submillimeter and subdegree accuracy required by SRS

  3. Gamma Knife radiosurgery for hemangioma of the cavernous sinus.

    Science.gov (United States)

    Lee, Cheng-Chia; Sheehan, Jason P; Kano, Hideyuki; Akpinar, Berkcan; Martinez-Alvarez, Roberto; Martinez-Moreno, Nuria; Guo, Wan-Yuo; Lunsford, L Dade; Liu, Kang-Du

    2017-05-01

    OBJECTIVE Cavernous sinus hemangiomas (CSHs) are rare vascular tumors. A direct microsurgical approach usually results in massive hemorrhage and incomplete tumor resection. Although stereotactic radiosurgery (SRS) has emerged as a therapeutic alternative to microsurgery, outcome studies are few. Authors of the present study evaluated the role of SRS for CSH. METHODS An international multicenter study was conducted to review outcome data in 31 patients with CSH. Eleven patients had initial microsurgery before SRS, and the other 20 patients (64.5%) underwent Gamma Knife SRS as the primary management for their CSH. Median age at the time of radiosurgery was 47 years, and 77.4% of patients had cranial nerve dysfunction before SRS. Patients received a median tumor margin dose of 12.6 Gy (range 12-19 Gy) at a median isodose of 55%. RESULTS Tumor regression was confirmed by imaging in all 31 patients, and all patients had greater than 50% reduction in tumor volume at 6 months post-SRS. No patient had delayed tumor growth, new cranial neuropathy, visual function deterioration, adverse radiation effects, or hypopituitarism after SRS. Twenty-four patients had presented with cranial nerve disorders before SRS, and 6 (25%) of them had gradual improvement. Four (66.7%) of the 6 patients with orbital symptoms had symptomatic relief at the last follow-up. CONCLUSIONS Stereotactic radiosurgery was effective in reducing the volume of CSH and attaining long-term tumor control in all patients at a median of 40 months. The authors' experience suggests that SRS is a reasonable primary and adjuvant treatment modality for patients in whom a CSH is diagnosed.

  4. Linear accelerator radiosurgery for trigeminal neuralgia: case report

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Hyong Geun [Dongguk University International Hospital, Goyang (Korea, Republic of)

    2006-06-15

    Trigeminal neuralgia is defined as an episodic electrical shock-like sensation in a dermatomal distribution of the trigeminal nerve. When medications fail to control pain, various procedures are used to attempt to control refractory pain. Of available procedures, stereotactic radiosurgery is the least invasive procedure and has been demonstrated to produce significant pain relief with minimal side effects. Recently, linear accelerators were introduced as a tool for radiosurgery of trigeminal neuralgia beneath the already accepted gamma unit. Author have experienced one case with trigeminal neuralgia treated with linear accelerator. The patient was treated with 85 Gy by means of 5 mm collimator directed to trigeminal nerve root entry zone. The patient obtained pain free without medication at 20 days after the procedure and remain pain free at 6 months after the procedure. He didn't experience facial numbness or other side effects.

  5. The Effect of Contouring Variability on Dosimetric Parameters for Brain Metastases Treated With Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Stanley, Julia; Dunscombe, Peter; Lau, Harold; Burns, Paul; Lim, Gerald; Liu, Hong-Wei; Nordal, Robert; Starreveld, Yves; Valev, Boris; Voroney, Jon-Paul; Spencer, David P.

    2013-01-01

    Purpose: To quantify the effect of contouring variation on stereotactic radiosurgery plan quality metrics for brain metastases. Methods and Materials: Fourteen metastases, each contoured by 8 physicians, formed the basis of this study. A template-based dynamic conformal 5-arc dose distribution was developed for each of the 112 contours, and each dose distribution was applied to the 7 other contours in each patient set. Radiation Therapy Oncology Group (RTOG) plan quality metrics and the Paddick conformity index were calculated for each of the 896 combinations of dose distributions and contours. Results: The ratio of largest to smallest contour volume for each metastasis varied from 1.25 to 4.47, with a median value of 1.68 (n=8). The median absolute difference in RTOG conformity index between the value for the reference contour and the values for the alternative contours was 0.35. The variation of the range of conformity index for all contours for a given tumor varied with the tumor size. Conclusions: The high degree of interobserver contouring variation strongly suggests that peer review or consultation should be adopted to standardize tumor volume prescription. Observer confidence was not reflected in contouring consistency. The impact of contouring variability on plan quality metrics, used as criteria for clinical trial protocol compliance, was such that the category of compliance was robust to interobserver effects only 70% of the time

  6. Hearing Outcomes After Stereotactic Radiosurgery for Unilateral Intracanalicular Vestibular Schwannomas: Implication of Transient Volume Expansion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young-Hoon [Department of Neurosurgery, Seoul National University Bundang Hospital, Seongnam-si (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Dong Gyu, E-mail: gknife@plaza.snu.ac.kr [Department of Neurosurgery, Seoul National University Hospital, Seoul (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Han, Jung Ho [Department of Neurosurgery, Seoul National University Bundang Hospital, Seongnam-si (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Chung, Hyun-Tai; Kim, In Kyung; Song, Sang Woo [Department of Neurosurgery, Seoul National University Hospital, Seoul (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Jeong-Hoon [Department of Neurosurgery, Seoul National University Bundang Hospital, Seongnam-si (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Jin Wook; Kim, Yong Hwy; Park, Chul-Kee [Department of Neurosurgery, Seoul National University Hospital, Seoul (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, Chae-Yong [Department of Neurosurgery, Seoul National University Bundang Hospital, Seongnam-si (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Paek, Sun Ha; Jung, Hee-Won [Department of Neurosurgery, Seoul National University Hospital, Seoul (Korea, Republic of); Department of Neurosurgery, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2013-01-01

    Purpose: We evaluated the prognostic factors for hearing outcomes after stereotactic radiosurgery (SRS) for unilateral sporadic intracanalicular vestibular schwannomas (IC-VSs) as a clinical homogeneous group of VSs. Methods and Materials: Sixty consecutive patients with unilateral sporadic IC-VSs, defined as tumors in the internal acoustic canal, and serviceable hearing (Gardner-Roberson grade 1 or 2) were treated with SRS as an initial treatment. The mean tumor volume was 0.34 {+-} 0.03 cm{sup 3} (range, 0.03-1.00 cm{sup 3}), and the mean marginal dose was 12.2 {+-} 0.1 Gy (range, 11.5-13.0 Gy). The median follow-up duration was 62 months (range, 36-141 months). Results: The actuarial rates of serviceable hearing preservation were 70%, 63%, and 55% at 1, 2, and 5 years after SRS, respectively. In multivariate analysis, transient volume expansion of {>=}20% from initial tumor size was a statistically significant risk factor for loss of serviceable hearing and hearing deterioration (increase of pure tone average {>=}20 dB) (odds ratio = 7.638; 95% confidence interval, 2.317-25.181; P=.001 and odds ratio = 3.507; 95% confidence interval, 1.228-10.018; P=.019, respectively). The cochlear radiation dose did not reach statistical significance. Conclusions: Transient volume expansion after SRS for VSs seems to be correlated with hearing deterioration when defined properly in a clinically homogeneous group of patients.

  7. Is whole brain radiation therapy needed for all patients with newly diagnosed brain metastases undergoing stereotactic radiosurgery?

    International Nuclear Information System (INIS)

    Suh, John H.; Barnett, Gene H.; Miller, David W.; Kupelian, Patrick A.; Cohen, Bruce H.

    1997-01-01

    PURPOSE: Since whole brain radiation therapy (WBRT) carries risks for long term survivors of brain metastases, some have advocated the use of stereotactic radiosurgery (SRS) alone for patients with brain metastases. We retrospectively reviewed our results of stereotactic radiosurgery (SRS) with immediate or delayed WBRT. MATERIALS/METHODS: From March 1990 to December 1996, linear accelerator-based SRS was performed on patients with Karnofsky score ≥ 70 and asymptomatic or mildly symptomatic brain metastases < 4 cm diameter. After excluding those patients with recurrent disease, 87 patients with 106 metastatic lesions (72 pts- single or solitary lesion, 13 pts- 2 lesions, 1 pt- 3 lesions, and 1 pt- 5 lesions) remained for analysis. The use of WBRT was dependent on physician preference but was given to all patients who developed local or regional failure after SRS. Survival was measured from the date of SRS until death or last follow-up using Kaplan-Meier method. Freedom from progression (FFP) was defined as no local or regional brain failure on follow-up radiographs and was measured from the date of SRS. RESULTS: Prognostic variables (age, sex, initial KPS, systemic disease, and extent of surgical resection) were similar for the 40 patients in the immediate WBRT group (iWBRT) and for the 47 patients in the delayed WBRT group (dWBRT). With a median follow-up of 5.8 months, no significant difference in median survival (6.9 months for both groups) was noted. On multivariate analysis, absence of systemic disease (p=0.008) and KPS 90-100 (p=0.001) were the only significant predictors for survival. For the 29 patients with a minimum KPS of 90 and no systemic disease, the median survival was 17.8 months. For those patients with a solitary lesion (no systemic disease), there was a trend for better median survival for the iWBRT group (22.8 months) versus the dWBRT group (9.3 months), p=0.06. FFP data was available on 78 patients (97 lesions). A significant difference was

  8. Delayed Complications in Patients Surviving at Least 3 Years After Stereotactic Radiosurgery for Brain Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Masaaki, E-mail: BCD06275@nifty.com [Katsuta Hospital Mito GammaHouse, Hitachi-naka (Japan); Department of Neurosurgery, Tokyo Women' s Medical University Medical Center East, Tokyo (Japan); Kawabe, Takuya [Katsuta Hospital Mito GammaHouse, Hitachi-naka (Japan); Department of Neurosurgery, Kyoto Prefectural University of Medicine Graduate School of Medical Sciences, Kyoto (Japan); Higuchi, Yoshinori [Department of Neurosurgery, Chiba University Graduate School of Medicine, Chiba (Japan); Sato, Yasunori [Clinical Research Center, Chiba University Graduate School of Medicine, Chiba (Japan); Nariai, Tadashi [Department of Neurosurgery, Graduate School, Tokyo Medical and Dental University School of Medicine, Tokyo (Japan); Barfod, Bierta E. [Katsuta Hospital Mito GammaHouse, Hitachi-naka (Japan); Kasuya, Hidetoshi [Department of Neurosurgery, Tokyo Women' s Medical University Medical Center East, Tokyo (Japan); Urakawa, Yoichi [Katsuta Hospital Mito GammaHouse, Hitachi-naka (Japan)

    2013-01-01

    Purpose: Little is known about delayed complications after stereotactic radiosurgery in long-surviving patients with brain metastases. We studied the actual incidence and predictors of delayed complications. Patients and Methods: This was an institutional review board-approved, retrospective cohort study that used our database. Among our consecutive series of 2000 patients with brain metastases who underwent Gamma Knife radiosurgery (GKRS) from 1991-2008, 167 patients (8.4%, 89 women, 78 men, mean age 62 years [range, 19-88 years]) who survived at least 3 years after GKRS were studied. Results: Among the 167 patients, 17 (10.2%, 18 lesions) experienced delayed complications (mass lesions with or without cyst in 8, cyst alone in 8, edema in 2) occurring 24.0-121.0 months (median, 57.5 months) after GKRS. The actuarial incidences of delayed complications estimated by competing risk analysis were 4.2% and 21.2% at the 60th month and 120th month, respectively, after GKRS. Among various pre-GKRS clinical factors, univariate analysis demonstrated tumor volume-related factors: largest tumor volume (hazard ratio [HR], 1.091; 95% confidence interval [CI], 1.018-1.154; P=.0174) and tumor volume {<=}10 cc vs >10 cc (HR, 4.343; 95% CI, 1.444-12.14; P=.0108) to be the only significant predictors of delayed complications. Univariate analysis revealed no correlations between delayed complications and radiosurgical parameters (ie, radiosurgical doses, conformity and gradient indexes, and brain volumes receiving >5 Gy and >12 Gy). After GKRS, an area of prolonged enhancement at the irradiated lesion was shown to be a possible risk factor for the development of delayed complications (HR, 8.751; 95% CI, 1.785-157.9; P=.0037). Neurosurgical interventions were performed in 13 patients (14 lesions) and mass removal for 6 lesions and Ommaya reservoir placement for the other 8. The results were favorable. Conclusions: Long-term follow-up is crucial for patients with brain metastases

  9. Neurocognitive Function of Patients with Brain Metastasis Who Received Either Whole Brain Radiotherapy Plus Stereotactic Radiosurgery or Radiosurgery Alone

    International Nuclear Information System (INIS)

    Aoyama, Hidefumi; Tago, Masao; Kato, Norio; Toyoda, Tatsuya; Kenjyo, Masahiro; Hirota, Saeko; Shioura, Hiroki; Inomata, Taisuke; Kunieda, Etsuo; Hayakawa, Kazushige; Nakagawa, Keiichi; Kobashi, Gen; Shirato, Hiroki

    2007-01-01

    Purpose: To determine how the omission of whole brain radiotherapy (WBRT) affects the neurocognitive function of patients with one to four brain metastases who have been treated with stereotactic radiosurgery (SRS). Methods and Materials: In a prospective randomized trial between WBRT+SRS and SRS alone for patients with one to four brain metastases, we assessed the neurocognitive function using the Mini-Mental State Examination (MMSE). Of the 132 enrolled patients, MMSE scores were available for 110. Results: In the baseline MMSE analyses, statistically significant differences were observed for total tumor volume, extent of tumor edema, age, and Karnofsky performance status. Of the 92 patients who underwent the follow-up MMSE, 39 had a baseline MMSE score of ≤27 (17 in the WBRT+SRS group and 22 in the SRS-alone group). Improvements of ≥3 points in the MMSEs of 9 WBRT+SRS patients and 11 SRS-alone patients (p = 0.85) were observed. Of the 82 patients with a baseline MMSE score of ≥27 or whose baseline MMSE score was ≤26 but had improved to ≥27 after the initial brain treatment, the 12-, 24-, and 36-month actuarial free rate of the 3-point drop in the MMSE was 76.1%, 68.5%, and 14.7% in the WBRT+SRS group and 59.3%, 51.9%, and 51.9% in the SRS-alone group, respectively. The average duration until deterioration was 16.5 months in the WBRT+SRS group and 7.6 months in the SRS-alone group (p = 0.05). Conclusion: The results of the present study have revealed that, for most brain metastatic patients, control of the brain tumor is the most important factor for stabilizing neurocognitive function. However, the long-term adverse effects of WBRT on neurocognitive function might not be negligible

  10. Generation of narrow peaks in spectroscopy of charged particles

    Energy Technology Data Exchange (ETDEWEB)

    Dubbers, Dirk, E-mail: dubbers@physi.uni-heidelberg.de; Schmidt, Ulrich, E-mail: ulrich.schmidt@physi.uni-heidelberg.de

    2016-11-21

    In spectroscopy of charged particles, narrow peaks may appear in continuous spectra if magnetic transport of the particles is involved. These artefacts, which so far have escaped the attention of investigators, can develop whenever geometric detection efficiency is less than 100%. As such peaks may be misinterpreted as new physics, their generation is investigated, both analytically and experimentally, for various detector configurations, including those used in searches for the spontaneous decay of the vacuum in heavy-ion collisions.

  11. Constraints on rapidity-dependent initial conditions from charged-particle pseudorapidity densities and two-particle correlations

    Science.gov (United States)

    Ke, Weiyao; Moreland, J. Scott; Bernhard, Jonah E.; Bass, Steffen A.

    2017-10-01

    We study the initial three-dimensional spatial configuration of the quark-gluon plasma (QGP) produced in relativistic heavy-ion collisions using centrality and pseudorapidity-dependent measurements of the medium's charged particle density and two-particle correlations. A cumulant-generating function is first used to parametrize the rapidity dependence of local entropy deposition and extend arbitrary boost-invariant initial conditions to nonzero beam rapidities. The model is then compared to p +Pb and Pb + Pb charged-particle pseudorapidity densities and two-particle pseudorapidity correlations and systematically optimized using Bayesian parameter estimation to extract high-probability initial condition parameters. The optimized initial conditions are then compared to a number of experimental observables including the pseudorapidity-dependent anisotropic flows, event-plane decorrelations, and flow correlations. We find that the form of the initial local longitudinal entropy profile is well constrained by these experimental measurements.

  12. Hard scattering contribution to particle production in high energy heavy-ion collisions

    International Nuclear Information System (INIS)

    Pareek, Pooja; Mishra, Aditya Nath; Sahoo, Pragati; Sahoo, Raghunath

    2014-01-01

    Global observables like the multiplicity of produced charged particles and transverse energy, are the key observables used to characterize the properties of the matter created in heavy-ion collisions. In order to study the dependence of the charged particle density on colliding system, center of mass energy and collision centrality, there have been measurements starting few GeV to TeV energies at LHC. There is a need to understand the particle production contribution coming from the QCD hard processes, which scale with number of binary nucleon-nucleon collisions, N coll and soft processes scaling with number of participant nucleons, N part

  13. Measuring momentum for charged particle tomography

    Science.gov (United States)

    Morris, Christopher; Fraser, Andrew Mcleod; Schultz, Larry Joe; Borozdin, Konstantin N.; Klimenko, Alexei Vasilievich; Sossong, Michael James; Blanpied, Gary

    2010-11-23

    Methods, apparatus and systems for detecting charged particles and obtaining tomography of a volume by measuring charged particles including measuring the momentum of a charged particle passing through a charged particle detector. Sets of position sensitive detectors measure scattering of the charged particle. The position sensitive detectors having sufficient mass to cause the charged particle passing through the position sensitive detectors to scatter in the position sensitive detectors. A controller can be adapted and arranged to receive scattering measurements of the charged particle from the charged particle detector, determine at least one trajectory of the charged particle from the measured scattering; and determine at least one momentum measurement of the charged particle from the at least one trajectory. The charged particle can be a cosmic ray-produced charged particle, such as a cosmic ray-produced muon. The position sensitive detectors can be drift cells, such as gas-filled drift tubes.

  14. Long-Term Outcomes of Stereotactic Radiosurgery for Treatment of Cavernous Sinus Meningiomas

    International Nuclear Information System (INIS)

    Santos, Marcos Antonio dos; Bustos Pérez de Salcedo, José; Gutiérrez Diaz, José Angel; Calvo, Felipe A.; Samblás, José; Marsiglia, Hugo; Sallabanda, Kita

    2011-01-01

    Purpose: Patients with cavernous sinus meningiomas (CSM) have an elevated risk of surgical morbidity and mortality. Recurrence is often observed after partial resection. Stereotactic radiosurgery (SRS), either alone or combined with surgery, represents an important advance in CSM management, but long-term results are lacking. Methods and Materials: A total of 88 CSM patients, treated from January 1991 to December 2005, were retrospectively reviewed. The mean follow-up was 86.8 months (range, 17.1–179.4 months). Among the patients, 22 were followed for more than 10 years. There was a female predominance (84.1%). The age varied from 16 to 90 years (mean, 51.6). In all, 47 patients (53.4%) received SRS alone, and 41 patients (46.6%) had undergone surgery before SRS. A dose of 14 Gy was prescribed to isodose curves from 50% to 90%. In 25 patients (28.4%), as a result of the proximity to organs at risk, the prescribed dose did not completely cover the target. Results: After SRS, 65 (73.8%) patients presented with tumor volume reduction; 14 (15.9%) remained stable, and 9 (10.2%) had tumor progression. The progression-free survival was 92.5% at 5 years, and 82.5% at 10 years. Age, sex, maximal diameter of the treated tumor, previous surgery, and complete target coverage did not show significant associations with prognosis. Among the 88 treated patients, 17 experienced morbidity that was related to SRS, and 6 of these patients spontaneously recovered. Conclusions: SRS is an effective and safe treatment for CSM, feasible either in the primary or the postsurgical setting. Incomplete coverage of the target did not worsen outcomes. More than 80% of the patients remained free of disease progression during long-term follow-up.

  15. Long-Term Outcomes of Stereotactic Radiosurgery for Treatment of Cavernous Sinus Meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcos Antonio dos, E-mail: marcosrxt@gmail.com [Radiotherapy Department, Instituto Madrileno de Oncologia/Grupo IMO, Madrid (Spain); Bustos Perez de Salcedo, Jose; Gutierrez Diaz, Jose Angel [Radiotherapy Department, Instituto Madrileno de Oncologia/Grupo IMO, Madrid (Spain); Neurosurgery Department, Sanatorio San Francisco de Asis, Madrid (Spain); Calvo, Felipe A. [Radiotherapy Department, Instituto Madrileno de Oncologia/Grupo IMO, Madrid (Spain); Department of Oncology, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Samblas, Jose [Radiotherapy Department, Instituto Madrileno de Oncologia/Grupo IMO, Madrid (Spain); Neurosurgery Department, Sanatorio San Francisco de Asis, Madrid (Spain); Marsiglia, Hugo [Radiotherapy Department, Instituto Madrileno de Oncologia/Grupo IMO, Madrid (Spain); Sallabanda, Kita [Radiotherapy Department, Instituto Madrileno de Oncologia/Grupo IMO, Madrid (Spain); Neurosurgery Department, Sanatorio San Francisco de Asis, Madrid (Spain)

    2011-12-01

    Purpose: Patients with cavernous sinus meningiomas (CSM) have an elevated risk of surgical morbidity and mortality. Recurrence is often observed after partial resection. Stereotactic radiosurgery (SRS), either alone or combined with surgery, represents an important advance in CSM management, but long-term results are lacking. Methods and Materials: A total of 88 CSM patients, treated from January 1991 to December 2005, were retrospectively reviewed. The mean follow-up was 86.8 months (range, 17.1-179.4 months). Among the patients, 22 were followed for more than 10 years. There was a female predominance (84.1%). The age varied from 16 to 90 years (mean, 51.6). In all, 47 patients (53.4%) received SRS alone, and 41 patients (46.6%) had undergone surgery before SRS. A dose of 14 Gy was prescribed to isodose curves from 50% to 90%. In 25 patients (28.4%), as a result of the proximity to organs at risk, the prescribed dose did not completely cover the target. Results: After SRS, 65 (73.8%) patients presented with tumor volume reduction; 14 (15.9%) remained stable, and 9 (10.2%) had tumor progression. The progression-free survival was 92.5% at 5 years, and 82.5% at 10 years. Age, sex, maximal diameter of the treated tumor, previous surgery, and complete target coverage did not show significant associations with prognosis. Among the 88 treated patients, 17 experienced morbidity that was related to SRS, and 6 of these patients spontaneously recovered. Conclusions: SRS is an effective and safe treatment for CSM, feasible either in the primary or the postsurgical setting. Incomplete coverage of the target did not worsen outcomes. More than 80% of the patients remained free of disease progression during long-term follow-up.

  16. Heavy charged particle radiobiology: using enhanced biological effectiveness and improved beam focusing to advance cancer therapy.

    Science.gov (United States)

    Allen, Christopher; Borak, Thomas B; Tsujii, Hirohiko; Nickoloff, Jac A

    2011-06-03

    Ionizing radiation causes many types of DNA damage, including base damage and single- and double-strand breaks. Photons, including X-rays and γ-rays, are the most widely used type of ionizing radiation in radiobiology experiments, and in radiation cancer therapy. Charged particles, including protons and carbon ions, are seeing increased use as an alternative therapeutic modality. Although the facilities needed to produce high energy charged particle beams are more costly than photon facilities, particle therapy has shown improved cancer survival rates, reflecting more highly focused dose distributions and more severe DNA damage to tumor cells. Despite early successes of charged particle radiotherapy, there is room for further improvement, and much remains to be learned about normal and cancer cell responses to charged particle radiation. 2011 Elsevier B.V. All rights reserved.

  17. Acceptance, commissioning and quality control in radiosurgery

    International Nuclear Information System (INIS)

    Toreti, Dalila Luzia

    2009-01-01

    Stereotactic Radiosurgery is a treatment technique that uses narrow beams of radiation focused with great accuracy in a small lesion. The introduction of micro multi leaf collimators (mMLC) allows this technique to reach a higher degree of dose conformation of the target lesion allowing a smaller irradiation of critical structures and normal tissues. This paper presents the results of the acceptance tests and commissioning of a Varian 6EX linear accelerator dedicated to radiosurgery associated with the BrainLab micro multi leaf collimator installed in the Hospital das Clinicas da Faculdade de Medicina da USP (HC-FMUSP) and establish feasible quality assurance program for the services that employ this special technique. The results of the acceptance tests were satisfactory and are willing with the specifications provided by the manufacturer and the commissioning tests were within the international recommendations. The tests and measures that are part of quality control process should be specific to each treatment unit, and the need, frequency and levels of tolerance

  18. Hybrid surgery-radiosurgery therapy for metastatic epidural spinal cord compression: A prospective evaluation using patient-reported outcomes.

    Science.gov (United States)

    Barzilai, Ori; Amato, Mary-Kate; McLaughlin, Lily; Reiner, Anne S; Ogilvie, Shahiba Q; Lis, Eric; Yamada, Yoshiya; Bilsky, Mark H; Laufer, Ilya

    2018-05-01

    Patient-reported outcomes (PRO) represent an important measure of cancer therapy effect. For patients with metastatic epidural spinal cord compression (MESCC), hybrid therapy using separation surgery and stereotactic radiosurgery preserves neurologic function and provides tumor control. There is currently a paucity of data reporting PRO after such combined modality therapy for MESCC. Delineation of hybrid surgery-radiosurgery therapy effect on PRO validates the hybrid approach as an effective therapy resulting in meaningful symptom relief. Brief Pain Inventory (BPI) and MD Anderson Symptom Inventory-Spine Tumor (MDASI-SP), PROs validated in the cancer population, were prospectively collected. Patients with MESCC who underwent separation surgery followed by stereotactic radiosurgery were included. Separation surgery included a posterolateral approach without extensive cytoreductive tumor excision. A median postoperative radiosurgery dose of 2700 cGy was delivered. The change in PRO 3 months after the hybrid therapy represented the primary study outcome. Preoperative and postoperative evaluations were analyzed using the Wilcoxon signed-rank test for matched pairs. One hundred eleven patients were included. Hybrid therapy resulted in a significant reduction in the BPI items "worst" and "right now" pain ( P < .0001), and in all BPI constructs (severity, interference with daily activities, and pain experience, P < .001). The MDASI-SP demonstrated reduction in spine-specific pain severity and interference with general activity ( P < .001), along with decreased symptom interference ( P < .001). Validated PRO instruments showed that in patients with MESCC, hybrid therapy with separation surgery and radiosurgery results in a significant decrease in pain severity and symptom interference. These prospective data confirm the benefit of hybrid therapy for treatment of MESCC and should facilitate referral of patients with MESCC for surgical evaluation.

  19. Role of charged particle irradiations in the study of radiation damage correlation

    International Nuclear Information System (INIS)

    Ishino, S.; Sekimura, N.

    1990-01-01

    Charged particle irradiations were originally expected to provide means to simulate the effect of neutron irradiations. However, it has been recognized that quantitative and sometimes even qualitative simulation of neutron radiation damage is difficult and the role of the charged particle irradiations has shifted to establishing fission-fusion correlation based on fundamental understanding of the radiation damage phenomena. The authors have been studying radiation effects in fusion materials using energetic ions from the latter standpoint. In this paper, the authors review recent results using a heavy-ion/electron microscope link facility together with sets of small heavy ion and light ion accelerators on cascade damage produced by energetic primary recoils and on the effect of helium on microstructural and microchemical evolution. Some of the other applications of the ion accelerators will also be mentioned. (orig.)

  20. Surgical Resection of Brain Metastases and the Risk of Leptomeningeal Recurrence in Patients Treated With Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Johnson, Matthew D.; Avkshtol, Vladimir; Baschnagel, Andrew M.; Meyer, Kurt; Ye, Hong; Grills, Inga S.; Chen, Peter Y.; Maitz, Ann; Olson, Rick E.; Pieper, Daniel R.; Krauss, Daniel J.

    2016-01-01

    Purpose: Recent prospective data have shown that patients with solitary or oligometastatic disease to the brain may be treated with upfront stereotactic radiosurgery (SRS) with deferral of whole-brain radiation therapy (WBRT). This has been extrapolated to the treatment of patients with resected lesions. The aim of this study was to assess the risk of leptomeningeal disease (LMD) in patients treated with SRS to the postsurgical resection cavity for brain metastases compared with patients treated with SRS to intact metastases. Methods and Materials: Four hundred sixty-five patients treated with SRS without upfront WBRT at a single institution were identified; 330 of these with at least 3 months' follow-up were included in this analysis. One hundred twelve patients had undergone surgical resection of at least 1 lesion before SRS compared with 218 treated for intact metastases. Time to LMD and overall survival (OS) time were estimated from date of radiosurgery, and LMD was analyzed by the use of cumulative incidence method with death as a competing risk. Univariate and multivariate analyses were performed with competing risk regression to determine whether various clinical factors predicted for LMD. Results: With a median follow-up time of 9.0 months, 39 patients (12%) experienced LMD at a median of 6.0 months after SRS. At 1 year, the cumulative incidence of LMD, with death as a competing risk, was 5.2% for the patients without surgical resection versus 16.9% for those treated with surgery (Gray test, P<.01). On multivariate analysis, prior surgical resection (P<.01) and breast cancer primary (P=.03) were significant predictors of LMD development. The median OS times for patients undergoing surgery compared with SRS alone were 12.9 and 10.6 months, respectively (log-rank P=.06). Conclusions: In patients undergoing SRS with deferral of upfront WBRT for intracranial metastatic disease, prior surgical resection and breast cancer primary are associated with an

  1. Knowledge Modeling for the Outcome of Brain Stereotactic Radiosurgery

    Science.gov (United States)

    Hauck, Jillian E.

    Purpose: To build a model that will predict the survival time for patients that were treated with stereotactic radiosurgery for brain metastases using support vector machine (SVM) regression. Methods and Materials: This study utilized data from 481 patients, which were equally divided into training and validation datasets randomly. The SVM model used a Gaussian RBF function, along with various parameters, such as the size of the epsilon insensitive region and the cost parameter (C) that are used to control the amount of error tolerated by the model. The predictor variables for the SVM model consisted of the actual survival time of the patient, the number of brain metastases, the graded prognostic assessment (GPA) and Karnofsky Performance Scale (KPS) scores, prescription dose, and the largest planning target volume (PTV). The response of the model is the survival time of the patient. The resulting survival time predictions were analyzed against the actual survival times by single parameter classification and two-parameter classification. The predicted mean survival times within each classification were compared with the actual values to obtain the confidence interval associated with the model's predictions. In addition to visualizing the data on plots using the means and error bars, the correlation coefficients between the actual and predicted means of the survival times were calculated during each step of the classification. Results: The number of metastases and KPS scores, were consistently shown to be the strongest predictors in the single parameter classification, and were subsequently used as first classifiers in the two-parameter classification. When the survival times were analyzed with the number of metastases as the first classifier, the best correlation was obtained for patients with 3 metastases, while patients with 4 or 5 metastases had significantly worse results. When the KPS score was used as the first classifier, patients with a KPS score of 60 and

  2. Search for fractionally charged particles in pp collisions at $\\sqrt{s}$ = 7 TeV

    CERN Document Server

    Chatrchyan, Serguei; Sirunyan, Albert M; Tumasyan, Armen; Adam, Wolfgang; Aguilo, Ernest; Bergauer, Thomas; Dragicevic, Marko; Erö, Janos; Fabjan, Christian; Friedl, Markus; Fruehwirth, Rudolf; Ghete, Vasile Mihai; Hammer, Josef; Hörmann, Natascha; Hrubec, Josef; Jeitler, Manfred; Kiesenhofer, Wolfgang; Knünz, Valentin; Krammer, Manfred; Krätschmer, Ilse; Liko, Dietrich; Mikulec, Ivan; Pernicka, Manfred; Rahbaran, Babak; Rohringer, Christine; Rohringer, Herbert; Schöfbeck, Robert; Strauss, Josef; Taurok, Anton; Waltenberger, Wolfgang; Walzel, Gerhard; Widl, Edmund; Wulz, Claudia-Elisabeth; Mossolov, Vladimir; Shumeiko, Nikolai; Suarez Gonzalez, Juan; Bansal, Monika; Bansal, Sunil; Cornelis, Tom; De Wolf, Eddi A; Janssen, Xavier; Luyckx, Sten; Mucibello, Luca; Ochesanu, Silvia; Roland, Benoit; Rougny, Romain; Selvaggi, Michele; Staykova, Zlatka; Van Haevermaet, Hans; Van Mechelen, Pierre; Van Remortel, Nick; Van Spilbeeck, Alex; Blekman, Freya; Blyweert, Stijn; D'Hondt, Jorgen; Gonzalez Suarez, Rebeca; Kalogeropoulos, Alexis; Maes, Michael; Olbrechts, Annik; Van Doninck, Walter; Van Mulders, Petra; Van Onsem, Gerrit Patrick; Villella, Ilaria; Clerbaux, Barbara; De Lentdecker, Gilles; Dero, Vincent; Gay, Arnaud; Hreus, Tomas; Léonard, Alexandre; Marage, Pierre Edouard; Mohammadi, Abdollah; Reis, Thomas; Thomas, Laurent; Vander Marcken, Gil; Vander Velde, Catherine; Vanlaer, Pascal; Wang, Jian; Adler, Volker; Beernaert, Kelly; Cimmino, Anna; Costantini, Silvia; Garcia, Guillaume; Grunewald, Martin; Klein, Benjamin; Lellouch, Jérémie; Marinov, Andrey; Mccartin, Joseph; Ocampo Rios, Alberto Andres; Ryckbosch, Dirk; Strobbe, Nadja; Thyssen, Filip; Tytgat, Michael; Verwilligen, Piet; Walsh, Sinead; Yazgan, Efe; Zaganidis, Nicolas; Basegmez, Suzan; Bruno, Giacomo; Castello, Roberto; Ceard, Ludivine; Delaere, Christophe; Du Pree, Tristan; Favart, Denis; Forthomme, Laurent; Giammanco, Andrea; Hollar, Jonathan; Lemaitre, Vincent; Liao, Junhui; Militaru, Otilia; Nuttens, Claude; Pagano, Davide; Pin, Arnaud; Piotrzkowski, Krzysztof; Schul, Nicolas; Vizan Garcia, Jesus Manuel; Beliy, Nikita; Caebergs, Thierry; Daubie, Evelyne; Hammad, Gregory Habib; Alves, Gilvan; Correa Martins Junior, Marcos; De Jesus Damiao, Dilson; Martins, Thiago; Pol, Maria Elena; Henrique Gomes E Souza, Moacyr; Aldá Júnior, Walter Luiz; Carvalho, Wagner; Custódio, Analu; Melo Da Costa, Eliza; De Oliveira Martins, Carley; Fonseca De Souza, Sandro; Matos Figueiredo, Diego; Mundim, Luiz; Nogima, Helio; Oguri, Vitor; Prado Da Silva, Wanda Lucia; Santoro, Alberto; Soares Jorge, Luana; Sznajder, Andre; Souza Dos Anjos, Tiago; Bernardes, Cesar Augusto; De Almeida Dias, Flavia; Tomei, Thiago; De Moraes Gregores, Eduardo; Lagana, Caio; Da Cunha Marinho, Franciole; Mercadante, Pedro G; Novaes, Sergio F; Padula, Sandra; Genchev, Vladimir; Iaydjiev, Plamen; Piperov, Stefan; Rodozov, Mircho; Stoykova, Stefka; Sultanov, Georgi; Tcholakov, Vanio; Trayanov, Rumen; Vutova, Mariana; Dimitrov, Anton; Hadjiiska, Roumyana; Kozhuharov, Venelin; Litov, Leander; Pavlov, Borislav; Petkov, Peicho; Bian, Jian-Guo; Chen, Guo-Ming; Chen, He-Sheng; Jiang, Chun-Hua; Liang, Dong; Liang, Song; Meng, Xiangwei; Tao, Junquan; Wang, Jian; Wang, Xianyou; Wang, Zheng; Xiao, Hong; Xu, Ming; Zang, Jingjing; Zhang, Zhen; Asawatangtrakuldee, Chayanit; Ban, Yong; Guo, Yifei; Li, Wenbo; Liu, Shuai; Mao, Yajun; Qian, Si-Jin; Teng, Haiyun; Wang, Dayong; Zhang, Linlin; Zou, Wei; Avila, Carlos; Gomez, Juan Pablo; Gomez Moreno, Bernardo; Osorio Oliveros, Andres Felipe; Sanabria, Juan Carlos; Godinovic, Nikola; Lelas, Damir; Plestina, Roko; Polic, Dunja; Puljak, Ivica; Antunovic, Zeljko; Kovac, Marko; Brigljevic, Vuko; Duric, Senka; Kadija, Kreso; Luetic, Jelena; Morovic, Srecko; Attikis, Alexandros; Galanti, Mario; Mavromanolakis, Georgios; Mousa, Jehad; Nicolaou, Charalambos; Ptochos, Fotios; Razis, Panos A; Finger, Miroslav; Finger Jr, Michael; Assran, Yasser; Elgammal, Sherif; Ellithi Kamel, Ali; Khalil, Shaaban; Mahmoud, Mohammed; Radi, Amr; Kadastik, Mario; Müntel, Mait; Raidal, Martti; Rebane, Liis; Tiko, Andres; Eerola, Paula; Fedi, Giacomo; Voutilainen, Mikko; Härkönen, Jaakko; Heikkinen, Mika Aatos; Karimäki, Veikko; Kinnunen, Ritva; Kortelainen, Matti J; Lampén, Tapio; Lassila-Perini, Kati; Lehti, Sami; Lindén, Tomas; Luukka, Panja-Riina; Mäenpää, Teppo; Peltola, Timo; Tuominen, Eija; Tuominiemi, Jorma; Tuovinen, Esa; Ungaro, Donatella; Wendland, Lauri; Banzuzi, Kukka; Karjalainen, Ahti; Korpela, Arja; Tuuva, Tuure; Besancon, Marc; Choudhury, Somnath; Dejardin, Marc; Denegri, Daniel; Fabbro, Bernard; Faure, Jean-Louis; Ferri, Federico; Ganjour, Serguei; Givernaud, Alain; Gras, Philippe; Hamel de Monchenault, Gautier; Jarry, Patrick; Locci, Elizabeth; Malcles, Julie; Millischer, Laurent; Nayak, Aruna; Rander, John; Rosowsky, André; Shreyber, Irina; Titov, Maksym; Baffioni, Stephanie; Beaudette, Florian; Benhabib, Lamia; Bianchini, Lorenzo; Bluj, Michal; Broutin, Clementine; Busson, Philippe; Charlot, Claude; Daci, Nadir; Dahms, Torsten; Dobrzynski, Ludwik; Granier de Cassagnac, Raphael; Haguenauer, Maurice; Miné, Philippe; Mironov, Camelia; Naranjo, Ivo Nicolas; Nguyen, Matthew; Ochando, Christophe; Paganini, Pascal; Sabes, David; Salerno, Roberto; Sirois, Yves; Veelken, Christian; Zabi, Alexandre; Agram, Jean-Laurent; Andrea, Jeremy; Bloch, Daniel; Bodin, David; Brom, Jean-Marie; Cardaci, Marco; Chabert, Eric Christian; Collard, Caroline; Conte, Eric; Drouhin, Frédéric; Ferro, Cristina; Fontaine, Jean-Charles; Gelé, Denis; Goerlach, Ulrich; Juillot, Pierre; Le Bihan, Anne-Catherine; Van Hove, Pierre; Fassi, Farida; Mercier, Damien; Beauceron, Stephanie; Beaupere, Nicolas; Bondu, Olivier; Boudoul, Gaelle; Chasserat, Julien; Chierici, Roberto; Contardo, Didier; Depasse, Pierre; El Mamouni, Houmani; Fay, Jean; Gascon, Susan; Gouzevitch, Maxime; Ille, Bernard; Kurca, Tibor; Lethuillier, Morgan; Mirabito, Laurent; Perries, Stephane; Sgandurra, Louis; Sordini, Viola; Tschudi, Yohann; Verdier, Patrice; Viret, Sébastien; Tsamalaidze, Zviad; Anagnostou, Georgios; Autermann, Christian; Beranek, Sarah; Edelhoff, Matthias; Feld, Lutz; Heracleous, Natalie; Hindrichs, Otto; Jussen, Ruediger; Klein, Katja; Merz, Jennifer; Ostapchuk, Andrey; Perieanu, Adrian; Raupach, Frank; Sammet, Jan; Schael, Stefan; Sprenger, Daniel; Weber, Hendrik; Wittmer, Bruno; Zhukov, Valery; Ata, Metin; Caudron, Julien; Dietz-Laursonn, Erik; Duchardt, Deborah; Erdmann, Martin; Fischer, Robert; Güth, Andreas; Hebbeker, Thomas; Heidemann, Carsten; Hoepfner, Kerstin; Klingebiel, Dennis; Kreuzer, Peter; Merschmeyer, Markus; Meyer, Arnd; Olschewski, Mark; Papacz, Paul; Pieta, Holger; Reithler, Hans; Schmitz, Stefan Antonius; Sonnenschein, Lars; Steggemann, Jan; Teyssier, Daniel; Weber, Martin; Bontenackels, Michael; Cherepanov, Vladimir; Erdogan, Yusuf; Flügge, Günter; Geenen, Heiko; Geisler, Matthias; Haj Ahmad, Wael; Hoehle, Felix; Kargoll, Bastian; Kress, Thomas; Kuessel, Yvonne; Lingemann, Joschka; Nowack, Andreas; Perchalla, Lars; Pooth, Oliver; Sauerland, Philip; Stahl, Achim; Aldaya Martin, Maria; Behr, Joerg; Behrenhoff, Wolf; Behrens, Ulf; Bergholz, Matthias; Bethani, Agni; Borras, Kerstin; Burgmeier, Armin; Cakir, Altan; Calligaris, Luigi; Campbell, Alan; Castro, Elena; Costanza, Francesco; Dammann, Dirk; Diez Pardos, Carmen; Eckerlin, Guenter; Eckstein, Doris; Flucke, Gero; Geiser, Achim; Glushkov, Ivan; Gunnellini, Paolo; Habib, Shiraz; Hauk, Johannes; Hellwig, Gregor; Jung, Hannes; Kasemann, Matthias; Katsas, Panagiotis; Kleinwort, Claus; Kluge, Hannelies; Knutsson, Albert; Krämer, Mira; Krücker, Dirk; Kuznetsova, Ekaterina; Lange, Wolfgang; Lohmann, Wolfgang; Lutz, Benjamin; Mankel, Rainer; Marfin, Ihar; Marienfeld, Markus; Melzer-Pellmann, Isabell-Alissandra; Meyer, Andreas Bernhard; Mnich, Joachim; Mussgiller, Andreas; Naumann-Emme, Sebastian; Novgorodova, Olga; Olzem, Jan; Perrey, Hanno; Petrukhin, Alexey; Pitzl, Daniel; Raspereza, Alexei; Ribeiro Cipriano, Pedro M; Riedl, Caroline; Ron, Elias; Rosin, Michele; Salfeld-Nebgen, Jakob; Schmidt, Ringo; Schoerner-Sadenius, Thomas; Sen, Niladri; Spiridonov, Alexander; Stein, Matthias; Walsh, Roberval; Wissing, Christoph; Blobel, Volker; Draeger, Jula; Enderle, Holger; Erfle, Joachim; Gebbert, Ulla; Görner, Martin; Hermanns, Thomas; Höing, Rebekka Sophie; Kaschube, Kolja; Kaussen, Gordon; Kirschenmann, Henning; Klanner, Robert; Lange, Jörn; Mura, Benedikt; Nowak, Friederike; Peiffer, Thomas; Pietsch, Niklas; Rathjens, Denis; Sander, Christian; Schettler, Hannes; Schleper, Peter; Schlieckau, Eike; Schmidt, Alexander; Schröder, Matthias; Schum, Torben; Seidel, Markus; Sola, Valentina; Stadie, Hartmut; Steinbrück, Georg; Thomsen, Jan; Vanelderen, Lukas; Barth, Christian; Berger, Joram; Böser, Christian; Chwalek, Thorsten; De Boer, Wim; Descroix, Alexis; Dierlamm, Alexander; Feindt, Michael; Guthoff, Moritz; Hackstein, Christoph; Hartmann, Frank; Hauth, Thomas; Heinrich, Michael; Held, Hauke; Hoffmann, Karl-Heinz; Husemann, Ulrich; Katkov, Igor; Komaragiri, Jyothsna Rani; Lobelle Pardo, Patricia; Martschei, Daniel; Mueller, Steffen; Müller, Thomas; Niegel, Martin; Nürnberg, Andreas; Oberst, Oliver; Oehler, Andreas; Ott, Jochen; Quast, Gunter; Rabbertz, Klaus; Ratnikov, Fedor; Ratnikova, Natalia; Röcker, Steffen; Schilling, Frank-Peter; Schott, Gregory; Simonis, Hans-Jürgen; Stober, Fred-Markus Helmut; Troendle, Daniel; Ulrich, Ralf; Wagner-Kuhr, Jeannine; Wayand, Stefan; Weiler, Thomas; Zeise, Manuel; Daskalakis, Georgios; Geralis, Theodoros; Kesisoglou, Stilianos; Kyriakis, Aristotelis; Loukas, Demetrios; Manolakos, Ioannis; Markou, Athanasios; Markou, Christos; Mavrommatis, Charalampos; Ntomari, Eleni; Gouskos, Loukas; Mertzimekis, Theodoros; Panagiotou, Apostolos; Saoulidou, Niki; Evangelou, Ioannis; Foudas, Costas; Kokkas, Panagiotis; Manthos, Nikolaos; Papadopoulos, Ioannis; Patras, Vaios; Bencze, Gyorgy; Hajdu, Csaba; Hidas, Pàl; Horvath, Dezso; Sikler, Ferenc; Veszpremi, Viktor; Vesztergombi, Gyorgy; Beni, Noemi; Czellar, Sandor; Molnar, Jozsef; Palinkas, Jozsef; Szillasi, Zoltan; Karancsi, János; Raics, Peter; Trocsanyi, Zoltan Laszlo; Ujvari, Balazs; Beri, Suman Bala; Bhatnagar, Vipin; Dhingra, Nitish; Gupta, Ruchi; Kaur, Manjit; Mehta, Manuk Zubin; Nishu, Nishu; Saini, Lovedeep Kaur; Sharma, Archana; Singh, Jasbir; Kumar, Ashok; Kumar, Arun; Ahuja, Sudha; Bhardwaj, Ashutosh; Choudhary, Brajesh C; Malhotra, Shivali; Naimuddin, Md; Ranjan, Kirti; Sharma, Varun; Shivpuri, Ram Krishen; Banerjee, Sunanda; Bhattacharya, Satyaki; Dutta, Suchandra; Gomber, Bhawna; Jain, Sandhya; Jain, Shilpi; Khurana, Raman; Sarkar, Subir; Sharan, Manoj; Abdulsalam, Abdulla; Choudhury, Rajani Kant; Dutta, Dipanwita; Kailas, Swaminathan; Kumar, Vineet; Mehta, Pourus; Mohanty, Ajit Kumar; Pant, Lalit Mohan; Shukla, Prashant; Aziz, Tariq; Ganguly, Sanmay; Guchait, Monoranjan; Maity, Manas; Majumder, Gobinda; Mazumdar, Kajari; Mohanty, Gagan Bihari; Parida, Bibhuti; Sudhakar, Katta; Wickramage, Nadeesha; Banerjee, Sudeshna; Dugad, Shashikant; Arfaei, Hessamaddin; Bakhshiansohi, Hamed; Etesami, Seyed Mohsen; Fahim, Ali; Hashemi, Majid; Hesari, Hoda; Jafari, Abideh; Khakzad, Mohsen; Mohammadi Najafabadi, Mojtaba; Paktinat Mehdiabadi, Saeid; Safarzadeh, Batool; Zeinali, Maryam; Abbrescia, Marcello; Barbone, Lucia; Calabria, Cesare; Chhibra, Simranjit Singh; Colaleo, Anna; Creanza, Donato; De Filippis, Nicola; De Palma, Mauro; Fiore, Luigi; Iaselli, Giuseppe; Lusito, Letizia; Maggi, Giorgio; Maggi, Marcello; Marangelli, Bartolomeo; My, Salvatore; Nuzzo, Salvatore; Pacifico, Nicola; Pompili, Alexis; Pugliese, Gabriella; Selvaggi, Giovanna; Silvestris, Lucia; Singh, Gurpreet; Venditti, Rosamaria; Zito, Giuseppe; Abbiendi, Giovanni; Benvenuti, Alberto; Bonacorsi, Daniele; Braibant-Giacomelli, Sylvie; Brigliadori, Luca; Capiluppi, Paolo; Castro, Andrea; Cavallo, Francesca Romana; Cuffiani, Marco; Dallavalle, Gaetano-Marco; Fabbri, Fabrizio; Fanfani, Alessandra; Fasanella, Daniele; Giacomelli, Paolo; Grandi, Claudio; Guiducci, Luigi; Marcellini, Stefano; Masetti, Gianni; Meneghelli, Marco; Montanari, Alessandro; Navarria, Francesco; Odorici, Fabrizio; Perrotta, Andrea; Primavera, Federica; Rossi, Antonio; Rovelli, Tiziano; Siroli, Gian Piero; Travaglini, Riccardo; Albergo, Sebastiano; Cappello, Gigi; Chiorboli, Massimiliano; Costa, Salvatore; Potenza, Renato; Tricomi, Alessia; Tuve, Cristina; Barbagli, Giuseppe; Ciulli, Vitaliano; Civinini, Carlo; D'Alessandro, Raffaello; Focardi, Ettore; Frosali, Simone; Gallo, Elisabetta; Gonzi, Sandro; Meschini, Marco; Paoletti, Simone; Sguazzoni, Giacomo; Tropiano, Antonio; Benussi, Luigi; Bianco, Stefano; Colafranceschi, Stefano; Fabbri, Franco; Piccolo, Davide; Fabbricatore, Pasquale; Musenich, Riccardo; Tosi, Silvano; Benaglia, Andrea; De Guio, Federico; Di Matteo, Leonardo; Fiorendi, Sara; Gennai, Simone; Ghezzi, Alessio; Malvezzi, Sandra; Manzoni, Riccardo Andrea; Martelli, Arabella; Massironi, Andrea; Menasce, Dario; Moroni, Luigi; Paganoni, Marco; Pedrini, Daniele; Ragazzi, Stefano; Redaelli, Nicola; Sala, Silvano; Tabarelli de Fatis, Tommaso; Buontempo, Salvatore; Carrillo Montoya, Camilo Andres; Cavallo, Nicola; De Cosa, Annapaola; Dogangun, Oktay; Fabozzi, Francesco; Iorio, Alberto Orso Maria; Lista, Luca; Meola, Sabino; Merola, Mario; Paolucci, Pierluigi; Azzi, Patrizia; Bacchetta, Nicola; Bisello, Dario; Branca, Antonio; Carlin, Roberto; Checchia, Paolo; Dorigo, Tommaso; Gasparini, Fabrizio; Gasparini, Ugo; Gozzelino, Andrea; Kanishchev, Konstantin; Lacaprara, Stefano; Lazzizzera, Ignazio; Margoni, Martino; Meneguzzo, Anna Teresa; Pazzini, Jacopo; Pozzobon, Nicola; Ronchese, Paolo; Simonetto, Franco; Torassa, Ezio; Tosi, Mia; Vanini, Sara; Zotto, Pierluigi; Zucchetta, Alberto; Zumerle, Gianni; Gabusi, Michele; Ratti, Sergio P; Riccardi, Cristina; Torre, Paola; Vitulo, Paolo; Biasini, Maurizio; Bilei, Gian Mario; Fanò, Livio; Lariccia, Paolo; Mantovani, Giancarlo; Menichelli, Mauro; Nappi, Aniello; Romeo, Francesco; Saha, Anirban; Santocchia, Attilio; Spiezia, Aniello; Taroni, Silvia; Azzurri, Paolo; Bagliesi, Giuseppe; Bernardini, Jacopo; Boccali, Tommaso; Broccolo, Giuseppe; Castaldi, Rino; D'Agnolo, Raffaele Tito; Dell'Orso, Roberto; Fiori, Francesco; Foà, Lorenzo; Giassi, Alessandro; Kraan, Aafke; Ligabue, Franco; Lomtadze, Teimuraz; Martini, Luca; Messineo, Alberto; Palla, Fabrizio; Rizzi, Andrea; Serban, Alin Titus; Spagnolo, Paolo; Squillacioti, Paola; Tenchini, Roberto; Tonelli, Guido; Venturi, Andrea; Verdini, Piero Giorgio; Barone, Luciano; Cavallari, Francesca; Del Re, Daniele; Diemoz, Marcella; Fanelli, Cristiano; Grassi, Marco; Longo, Egidio; Meridiani, Paolo; Micheli, Francesco; Nourbakhsh, Shervin; Organtini, Giovanni; Paramatti, Riccardo; Rahatlou, Shahram; Sigamani, Michael; Soffi, Livia; Amapane, Nicola; Arcidiacono, Roberta; Argiro, Stefano; Arneodo, Michele; Biino, Cristina; Cartiglia, Nicolo; Costa, Marco; Demaria, Natale; Mariotti, Chiara; Maselli, Silvia; Migliore, Ernesto; Monaco, Vincenzo; Musich, Marco; Obertino, Maria Margherita; Pastrone, Nadia; Pelliccioni, Mario; Potenza, Alberto; Romero, Alessandra; Ruspa, Marta; Sacchi, Roberto; Solano, Ada; Staiano, Amedeo; Vilela Pereira, Antonio; Belforte, Stefano; Candelise, Vieri; Casarsa, Massimo; Cossutti, Fabio; Della Ricca, Giuseppe; Gobbo, Benigno; Marone, Matteo; Montanino, Damiana; Penzo, Aldo; Schizzi, Andrea; Heo, Seong Gu; Kim, Tae Yeon; Nam, Soon-Kwon; Chang, Sunghyun; Kim, Dong Hee; Kim, Gui Nyun; Kong, Dae Jung; Park, Hyangkyu; Ro, Sang-Ryul; Son, Dong-Chul; Son, Taejin; Kim, Jae Yool; Kim, Zero Jaeho; Song, Sanghyeon; Choi, Suyong; Gyun, Dooyeon; Hong, Byung-Sik; Jo, Mihee; Kim, Hyunchul; Kim, Tae Jeong; Lee, Kyong Sei; Moon, Dong Ho; Park, Sung Keun; Choi, Minkyoo; Kim, Ji Hyun; Park, Chawon; Park, Inkyu; Park, Sangnam; Ryu, Geonmo; Cho, Yongjin; Choi, Young-Il; Choi, Young Kyu; Goh, Junghwan; Kim, Min Suk; Kwon, Eunhyang; Lee, Byounghoon; Lee, Jongseok; Lee, Sungeun; Seo, Hyunkwan; Yu, Intae; Bilinskas, Mykolas Jurgis; Grigelionis, Ignas; Janulis, Mindaugas; Juodagalvis, Andrius; Castilla-Valdez, Heriberto; De La Cruz-Burelo, Eduard; Heredia-de La Cruz, Ivan; Lopez-Fernandez, Ricardo; Magaña Villalba, Ricardo; Martínez-Ortega, Jorge; Sánchez-Hernández, Alberto; Villasenor-Cendejas, Luis Manuel; Carrillo Moreno, Salvador; Vazquez Valencia, Fabiola; Salazar Ibarguen, Humberto Antonio; Casimiro Linares, Edgar; Morelos Pineda, Antonio; Reyes-Santos, Marco A; Krofcheck, David; Bell, Alan James; Butler, Philip H; Doesburg, Robert; Reucroft, Steve; Silverwood, Hamish; Ahmad, Muhammad; Ansari, Muhammad Hamid; Asghar, Muhammad Irfan; Hoorani, Hafeez R; Khalid, Shoaib; Khan, Wajid Ali; Khurshid, Taimoor; Qazi, Shamona; Shah, Mehar Ali; Shoaib, Muhammad; Bialkowska, Helena; Boimska, Bozena; Frueboes, Tomasz; Gokieli, Ryszard; Górski, Maciej; Kazana, Malgorzata; Nawrocki, Krzysztof; Romanowska-Rybinska, Katarzyna; Szleper, Michal; Wrochna, Grzegorz; Zalewski, Piotr; Brona, Grzegorz; Bunkowski, Karol; Cwiok, Mikolaj; Dominik, Wojciech; Doroba, Krzysztof; Kalinowski, Artur; Konecki, Marcin; Krolikowski, Jan; Almeida, Nuno; Bargassa, Pedrame; David Tinoco Mendes, Andre; Faccioli, Pietro; Ferreira Parracho, Pedro Guilherme; Gallinaro, Michele; Seixas, Joao; Varela, Joao; Vischia, Pietro; Bunin, Pavel; Gavrilenko, Mikhail; Golutvin, Igor; Gorbunov, Ilya; Karjavin, Vladimir; Konoplyanikov, Viktor; Kozlov, Guennady; Lanev, Alexander; Malakhov, Alexander; Moisenz, Petr; Palichik, Vladimir; Perelygin, Victor; Savina, Maria; Shmatov, Sergey; Smirnov, Vitaly; Volodko, Anton; Zarubin, Anatoli; Evstyukhin, Sergey; Golovtsov, Victor; Ivanov, Yury; Kim, Victor; Levchenko, Petr; Murzin, Victor; Oreshkin, Vadim; Smirnov, Igor; Sulimov, Valentin; Uvarov, Lev; Vavilov, Sergey; Vorobyev, Alexey; Vorobyev, Andrey; Andreev, Yuri; Dermenev, Alexander; Gninenko, Sergei; Golubev, Nikolai; Kirsanov, Mikhail; Krasnikov, Nikolai; Matveev, Viktor; Pashenkov, Anatoli; Tlisov, Danila; Toropin, Alexander; Epshteyn, Vladimir; Erofeeva, Maria; Gavrilov, Vladimir; Kossov, Mikhail; Lychkovskaya, Natalia; Popov, Vladimir; Safronov, Grigory; Semenov, Sergey; Stolin, Viatcheslav; Vlasov, Evgueni; Zhokin, Alexander; Belyaev, Andrey; Boos, Edouard; Dubinin, Mikhail; Dudko, Lev; Ershov, Alexander; Gribushin, Andrey; Klyukhin, Vyacheslav; Kodolova, Olga; Lokhtin, Igor; Markina, Anastasia; Obraztsov, Stepan; Perfilov, Maxim; Petrushanko, Sergey; Popov, Andrey; Sarycheva, Ludmila; Savrin, Viktor; Snigirev, Alexander; Andreev, Vladimir; Azarkin, Maksim; Dremin, Igor; Kirakosyan, Martin; Leonidov, Andrey; Mesyats, Gennady; Rusakov, Sergey V; Vinogradov, Alexey; Azhgirey, Igor; Bayshev, Igor; Bitioukov, Sergei; Grishin, Viatcheslav; Kachanov, Vassili; Konstantinov, Dmitri; Krychkine, Victor; Petrov, Vladimir; Ryutin, Roman; Sobol, Andrei; Tourtchanovitch, Leonid; Troshin, Sergey; Tyurin, Nikolay; Uzunian, Andrey; Volkov, Alexey; Adzic, Petar; Djordjevic, Milos; Ekmedzic, Marko; Krpic, Dragomir; Milosevic, Jovan; Aguilar-Benitez, Manuel; Alcaraz Maestre, Juan; Arce, Pedro; Battilana, Carlo; Calvo, Enrique; Cerrada, Marcos; Chamizo Llatas, Maria; Colino, Nicanor; De La Cruz, Begona; Delgado Peris, Antonio; Domínguez Vázquez, Daniel; Fernandez Bedoya, Cristina; Fernández Ramos, Juan Pablo; Ferrando, Antonio; Flix, Jose; Fouz, Maria Cruz; Garcia-Abia, Pablo; Gonzalez Lopez, Oscar; Goy Lopez, Silvia; Hernandez, Jose M; Josa, Maria Isabel; Merino, Gonzalo; Puerta Pelayo, Jesus; Quintario Olmeda, Adrián; Redondo, Ignacio; Romero, Luciano; Santaolalla, Javier; Senghi Soares, Mara; Willmott, Carlos; Albajar, Carmen; Codispoti, Giuseppe; de Trocóniz, Jorge F; Brun, Hugues; Cuevas, Javier; Fernandez Menendez, Javier; Folgueras, Santiago; Gonzalez Caballero, Isidro; Lloret Iglesias, Lara; Piedra Gomez, Jonatan; Brochero Cifuentes, Javier Andres; Cabrillo, Iban Jose; Calderon, Alicia; Chuang, Shan-Huei; Duarte Campderros, Jordi; Felcini, Marta; Fernandez, Marcos; Gomez, Gervasio; Gonzalez Sanchez, Javier; Graziano, Alberto; Jorda, Clara; Lopez Virto, Amparo; Marco, Jesus; Marco, Rafael; Martinez Rivero, Celso; Matorras, Francisco; Munoz Sanchez, Francisca Javiela; Rodrigo, Teresa; Rodríguez-Marrero, Ana Yaiza; Ruiz-Jimeno, Alberto; Scodellaro, Luca; Vila, Ivan; Vilar Cortabitarte, Rocio; Abbaneo, Duccio; Auffray, Etiennette; Auzinger, Georg; Bachtis, Michail; Baillon, Paul; Ball, Austin; Barney, David; Benitez, Jose F; Bernet, Colin; Bianchi, Giovanni; Bloch, Philippe; Bocci, Andrea; Bonato, Alessio; Botta, Cristina; Breuker, Horst; Camporesi, Tiziano; Cerminara, Gianluca; Christiansen, Tim; Coarasa Perez, Jose Antonio; D'Enterria, David; Dabrowski, Anne; De Roeck, Albert; Di Guida, Salvatore; Dobson, Marc; Dupont-Sagorin, Niels; Elliott-Peisert, Anna; Frisch, Benjamin; Funk, Wolfgang; Georgiou, Georgios; Giffels, Manuel; Gigi, Dominique; Gill, Karl; Giordano, Domenico; Girone, Maria; Giunta, Marina; Glege, Frank; Gomez-Reino Garrido, Robert; Govoni, Pietro; Gowdy, Stephen; Guida, Roberto; Hansen, Magnus; Harris, Philip; Hartl, Christian; Harvey, John; Hegner, Benedikt; Hinzmann, Andreas; Innocente, Vincenzo; Janot, Patrick; Kaadze, Ketino; Karavakis, Edward; Kousouris, Konstantinos; Lecoq, Paul; Lee, Yen-Jie; Lenzi, Piergiulio; Lourenco, Carlos; Magini, Nicolo; Maki, Tuula; Malberti, Martina; Malgeri, Luca; Mannelli, Marcello; Masetti, Lorenzo; Meijers, Frans; Mersi, Stefano; Meschi, Emilio; Moser, Roland; Mozer, Matthias Ulrich; Mulders, Martijn; Musella, Pasquale; Nesvold, Erik; Orimoto, Toyoko; Orsini, Luciano; Palencia Cortezon, Enrique; Perez, Emmanuelle; Perrozzi, Luca; Petrilli, Achille; Pfeiffer, Andreas; Pierini, Maurizio; Pimiä, Martti; Piparo, Danilo; Polese, Giovanni; Quertenmont, Loic; Racz, Attila; Reece, William; Rodrigues Antunes, Joao; Rolandi, Gigi; Rovelli, Chiara; Rovere, Marco; Sakulin, Hannes; Santanastasio, Francesco; Schäfer, Christoph; Schwick, Christoph; Segoni, Ilaria; Sekmen, Sezen; Sharma, Archana; Siegrist, Patrice; Silva, Pedro; Simon, Michal; Sphicas, Paraskevas; Spiga, Daniele; Tsirou, Andromachi; Veres, Gabor Istvan; Vlimant, Jean-Roch; Wöhri, Hermine Katharina; Worm, Steven; Zeuner, Wolfram Dietrich; Bertl, Willi; Deiters, Konrad; Erdmann, Wolfram; Gabathuler, Kurt; Horisberger, Roland; Ingram, Quentin; Kaestli, Hans-Christian; König, Stefan; Kotlinski, Danek; Langenegger, Urs; Meier, Frank; Renker, Dieter; Rohe, Tilman; Sibille, Jennifer; Bäni, Lukas; Bortignon, Pierluigi; Buchmann, Marco-Andrea; Casal, Bruno; Chanon, Nicolas; Deisher, Amanda; Dissertori, Günther; Dittmar, Michael; Donegà, Mauro; Dünser, Marc; Eugster, Jürg; Freudenreich, Klaus; Grab, Christoph; Hits, Dmitry; Lecomte, Pierre; Lustermann, Werner; Marini, Andrea Carlo; Martinez Ruiz del Arbol, Pablo; Mohr, Niklas; Moortgat, Filip; Nägeli, Christoph; Nef, Pascal; Nessi-Tedaldi, Francesca; Pandolfi, Francesco; Pape, Luc; Pauss, Felicitas; Peruzzi, Marco; Ronga, Frederic Jean; Rossini, Marco; Sala, Leonardo; Sanchez, Ann - Karin; Starodumov, Andrei; Stieger, Benjamin; Takahashi, Maiko; Tauscher, Ludwig; Thea, Alessandro; Theofilatos, Konstantinos; Treille, Daniel; Urscheler, Christina; Wallny, Rainer; Weber, Hannsjoerg Artur; Wehrli, Lukas; Amsler, Claude; Chiochia, Vincenzo; De Visscher, Simon; Favaro, Carlotta; Ivova Rikova, Mirena; Millan Mejias, Barbara; Otiougova, Polina; Robmann, Peter; Snoek, Hella; Tupputi, Salvatore; Verzetti, Mauro; Chang, Yuan-Hann; Chen, Kuan-Hsin; Kuo, Chia-Ming; Li, Syue-Wei; Lin, Willis; Liu, Zong-Kai; Lu, Yun-Ju; Mekterovic, Darko; Singh, Anil; Volpe, Roberta; Yu, Shin-Shan; Bartalini, Paolo; Chang, Paoti; Chang, You-Hao; Chang, Yu-Wei; Chao, Yuan; Chen, Kai-Feng; Dietz, Charles; Grundler, Ulysses; Hou, George Wei-Shu; Hsiung, Yee; Kao, Kai-Yi; Lei, Yeong-Jyi; Lu, Rong-Shyang; Majumder, Devdatta; Petrakou, Eleni; Shi, Xin; Shiu, Jing-Ge; Tzeng, Yeng-Ming; Wan, Xia; Wang, Minzu; Asavapibhop, Burin; Srimanobhas, Norraphat; Adiguzel, Aytul; Bakirci, Mustafa Numan; Cerci, Salim; Dozen, Candan; Dumanoglu, Isa; Eskut, Eda; Girgis, Semiray; Gokbulut, Gul; Gurpinar, Emine; Hos, Ilknur; Kangal, Evrim Ersin; Karaman, Turker; Karapinar, Guler; Kayis Topaksu, Aysel; Onengut, Gulsen; Ozdemir, Kadri; Ozturk, Sertac; Polatoz, Ayse; Sogut, Kenan; Sunar Cerci, Deniz; Tali, Bayram; Topakli, Huseyin; Vergili, Latife Nukhet; Vergili, Mehmet; Akin, Ilina Vasileva; Aliev, Takhmasib; Bilin, Bugra; Bilmis, Selcuk; Deniz, Muhammed; Gamsizkan, Halil; Guler, Ali Murat; Ocalan, Kadir; Ozpineci, Altug; Serin, Meltem; Sever, Ramazan; Surat, Ugur Emrah; Yalvac, Metin; Yildirim, Eda; Zeyrek, Mehmet; Gülmez, Erhan; Isildak, Bora; Kaya, Mithat; Kaya, Ozlem; Ozkorucuklu, Suat; Sonmez, Nasuf; Cankocak, Kerem; Levchuk, Leonid; Bostock, Francis; Brooke, James John; Clement, Emyr; Cussans, David; Flacher, Henning; Frazier, Robert; Goldstein, Joel; Grimes, Mark; Heath, Greg P; Heath, Helen F; Kreczko, Lukasz; Metson, Simon; Newbold, Dave M; Nirunpong, Kachanon; Poll, Anthony; Senkin, Sergey; Smith, Vincent J; Williams, Thomas; Basso, Lorenzo; Bell, Ken W; Belyaev, Alexander; Brew, Christopher; Brown, Robert M; Cockerill, David JA; Coughlan, John A; Harder, Kristian; Harper, Sam; Jackson, James; Kennedy, Bruce W; Olaiya, Emmanuel; Petyt, David; Radburn-Smith, Benjamin Charles; Shepherd-Themistocleous, Claire; Tomalin, Ian R; Womersley, William John; Bainbridge, Robert; Ball, Gordon; Beuselinck, Raymond; Buchmuller, Oliver; Colling, David; Cripps, Nicholas; Cutajar, Michael; Dauncey, Paul; Davies, Gavin; Della Negra, Michel; Ferguson, William; Fulcher, Jonathan; Futyan, David; Gilbert, Andrew; Guneratne Bryer, Arlo; Hall, Geoffrey; Hatherell, Zoe; Hays, Jonathan; Iles, Gregory; Jarvis, Martyn; Karapostoli, Georgia; Lyons, Louis; Magnan, Anne-Marie; Marrouche, Jad; Mathias, Bryn; Nandi, Robin; Nash, Jordan; Nikitenko, Alexander; Papageorgiou, Anastasios; Pela, Joao; Pesaresi, Mark; Petridis, Konstantinos; Pioppi, Michele; Raymond, David Mark; Rogerson, Samuel; Rose, Andrew; Ryan, Matthew John; Seez, Christopher; Sharp, Peter; Sparrow, Alex; Stoye, Markus; Tapper, Alexander; Vazquez Acosta, Monica; Virdee, Tejinder; Wakefield, Stuart; Wardle, Nicholas; Whyntie, Tom; Chadwick, Matthew; Cole, Joanne; Hobson, Peter R; Khan, Akram; Kyberd, Paul; Leggat, Duncan; Leslie, Dawn; Martin, William; Reid, Ivan; Symonds, Philip; Teodorescu, Liliana; Turner, Mark; Hatakeyama, Kenichi; Liu, Hongxuan; Scarborough, Tara; Charaf, Otman; Henderson, Conor; Rumerio, Paolo; Avetisyan, Aram; Bose, Tulika; Fantasia, Cory; Heister, Arno; St John, Jason; Lawson, Philip; Lazic, Dragoslav; Rohlf, James; Sperka, David; Sulak, Lawrence; Alimena, Juliette; Bhattacharya, Saptaparna; Cutts, David; Demiragli, Zeynep; Ferapontov, Alexey; Heintz, Ulrich; Jabeen, Shabnam; Kukartsev, Gennadiy; Laird, Edward; Landsberg, Greg; Luk, Michael; Narain, Meenakshi; Nguyen, Duong; Segala, Michael; Sinthuprasith, Tutanon; Speer, Thomas; Tsang, Ka Vang; Breedon, Richard; Breto, Guillermo; Calderon De La Barca Sanchez, Manuel; Chauhan, Sushil; Chertok, Maxwell; Conway, John; Conway, Rylan; Cox, Peter Timothy; Dolen, James; Erbacher, Robin; Gardner, Michael; Houtz, Rachel; Ko, Winston; Kopecky, Alexandra; Lander, Richard; Mall, Orpheus; Miceli, Tia; Pellett, Dave; Ricci-Tam, Francesca; Rutherford, Britney; Searle, Matthew; Smith, John; Squires, Michael; Tripathi, Mani; Vasquez Sierra, Ricardo; Yohay, Rachel; Andreev, Valeri; Cline, David; Cousins, Robert; Duris, Joseph; Erhan, Samim; Everaerts, Pieter; Farrell, Chris; Hauser, Jay; Ignatenko, Mikhail; Jarvis, Chad; Plager, Charles; Rakness, Gregory; Schlein, Peter; Traczyk, Piotr; Valuev, Vyacheslav; Weber, Matthias; Babb, John; Clare, Robert; Dinardo, Mauro Emanuele; Ellison, John Anthony; Gary, J William; Giordano, Ferdinando; Hanson, Gail; Jeng, Geng-Yuan; Liu, Hongliang; Long, Owen Rosser; Luthra, Arun; Nguyen, Harold; Paramesvaran, Sudarshan; Sturdy, Jared; Sumowidagdo, Suharyo; Wilken, Rachel; Wimpenny, Stephen; Andrews, Warren; Branson, James G; Cerati, Giuseppe Benedetto; Cittolin, Sergio; Evans, David; Golf, Frank; Holzner, André; Kelley, Ryan; Lebourgeois, Matthew; Letts, James; Macneill, Ian; Mangano, Boris; Padhi, Sanjay; Palmer, Christopher; Petrucciani, Giovanni; Pieri, Marco; Sani, Matteo; Sharma, Vivek; Simon, Sean; Sudano, Elizabeth; Tadel, Matevz; Tu, Yanjun; Vartak, Adish; Wasserbaech, Steven; Würthwein, Frank; Yagil, Avraham; Yoo, Jaehyeok; Barge, Derek; Bellan, Riccardo; Campagnari, Claudio; D'Alfonso, Mariarosaria; Danielson, Thomas; Flowers, Kristen; Geffert, Paul; Incandela, Joe; Justus, Christopher; Kalavase, Puneeth; Koay, Sue Ann; Kovalskyi, Dmytro; Krutelyov, Vyacheslav; Lowette, Steven; Mccoll, Nickolas; Pavlunin, Viktor; Rebassoo, Finn; Ribnik, Jacob; Richman, Jeffrey; Rossin, Roberto; Stuart, David; To, Wing; West, Christopher; Apresyan, Artur; Bornheim, Adolf; Chen, Yi; Di Marco, Emanuele; Duarte, Javier; Gataullin, Marat; Ma, Yousi; Mott, Alexander; Newman, Harvey B; Rogan, Christopher; Spiropulu, Maria; Timciuc, Vladlen; Veverka, Jan; Wilkinson, Richard; Xie, Si; Yang, Yong; Zhu, Ren-Yuan; Akgun, Bora; Azzolini, Virginia; Calamba, Aristotle; Carroll, Ryan; Ferguson, Thomas; Iiyama, Yutaro; Jang, Dong Wook; Liu, Yueh-Feng; Paulini, Manfred; Vogel, Helmut; Vorobiev, Igor; Cumalat, John Perry; Drell, Brian Robert; Ford, William T; Gaz, Alessandro; Luiggi Lopez, Eduardo; Smith, James; Stenson, Kevin; Ulmer, Keith; Wagner, Stephen Robert; Alexander, James; Chatterjee, Avishek; Eggert, Nicholas; Gibbons, Lawrence Kent; Heltsley, Brian; Khukhunaishvili, Aleko; Kreis, Benjamin; Mirman, Nathan; Nicolas Kaufman, Gala; Patterson, Juliet Ritchie; Ryd, Anders; Salvati, Emmanuele; Sun, Werner; Teo, Wee Don; Thom, Julia; Thompson, Joshua; Tucker, Jordan; Vaughan, Jennifer; Weng, Yao; Winstrom, Lucas; Wittich, Peter; Winn, Dave; Abdullin, Salavat; Albrow, Michael; Anderson, Jacob; Bauerdick, Lothar AT; Beretvas, Andrew; Berryhill, Jeffrey; Bhat, Pushpalatha C; Bloch, Ingo; Burkett, Kevin; Butler, Joel Nathan; Chetluru, Vasundhara; Cheung, Harry; Chlebana, Frank; Elvira, Victor Daniel; Fisk, Ian; Freeman, Jim; Gao, Yanyan; Green, Dan; Gutsche, Oliver; Hanlon, Jim; Harris, Robert M; Hirschauer, James; Hooberman, Benjamin; Jindariani, Sergo; Johnson, Marvin; Joshi, Umesh; Kilminster, Benjamin; Klima, Boaz; Kunori, Shuichi; Kwan, Simon; Leonidopoulos, Christos; Linacre, Jacob; Lincoln, Don; Lipton, Ron; Lykken, Joseph; Maeshima, Kaori; Marraffino, John Michael; Maruyama, Sho; Mason, David; McBride, Patricia; Mishra, Kalanand; Mrenna, Stephen; Musienko, Yuri; Newman-Holmes, Catherine; O'Dell, Vivian; Prokofyev, Oleg; Sexton-Kennedy, Elizabeth; Sharma, Seema; Spalding, William J; Spiegel, Leonard; Taylor, Lucas; Tkaczyk, Slawek; Tran, Nhan Viet; Uplegger, Lorenzo; Vaandering, Eric Wayne; Vidal, Richard; Whitmore, Juliana; Wu, Weimin; Yang, Fan; Yumiceva, Francisco; Yun, Jae Chul; Acosta, Darin; Avery, Paul; Bourilkov, Dimitri; Chen, Mingshui; Cheng, Tongguang; Das, Souvik; De Gruttola, Michele; Di Giovanni, Gian Piero; Dobur, Didar; Drozdetskiy, Alexey; Field, Richard D; Fisher, Matthew; Fu, Yu; Furic, Ivan-Kresimir; Gartner, Joseph; Hugon, Justin; Kim, Bockjoo; Konigsberg, Jacobo; Korytov, Andrey; Kropivnitskaya, Anna; Kypreos, Theodore; Low, Jia Fu; Matchev, Konstantin; Milenovic, Predrag; Mitselmakher, Guenakh; Muniz, Lana; Park, Myeonghun; Remington, Ronald; Rinkevicius, Aurelijus; Sellers, Paul; Skhirtladze, Nikoloz; Snowball, Matthew; Yelton, John; Zakaria, Mohammed; Gaultney, Vanessa; Hewamanage, Samantha; Lebolo, Luis Miguel; Linn, Stephan; Markowitz, Pete; Martinez, German; Rodriguez, Jorge Luis; Adams, Todd; Askew, Andrew; Bochenek, Joseph; Chen, Jie; Diamond, Brendan; Gleyzer, Sergei V; Haas, Jeff; Hagopian, Sharon; Hagopian, Vasken; Jenkins, Merrill; Johnson, Kurtis F; Prosper, Harrison; Veeraraghavan, Venkatesh; Weinberg, Marc; Baarmand, Marc M; Dorney, Brian; Hohlmann, Marcus; Kalakhety, Himali; Vodopiyanov, Igor; Adams, Mark Raymond; Anghel, Ioana Maria; Apanasevich, Leonard; Bai, Yuting; Bazterra, Victor Eduardo; Betts, Russell Richard; Bucinskaite, Inga; Callner, Jeremy; Cavanaugh, Richard; Evdokimov, Olga; Gauthier, Lucie; Gerber, Cecilia Elena; Hofman, David Jonathan; Khalatyan, Samvel; Lacroix, Florent; Malek, Magdalena; O'Brien, Christine; Silkworth, Christopher; Strom, Derek; Turner, Paul; Varelas, Nikos; Akgun, Ugur; Albayrak, Elif Asli; Bilki, Burak; Clarida, Warren; Duru, Firdevs; Merlo, Jean-Pierre; Mermerkaya, Hamit; Mestvirishvili, Alexi; Moeller, Anthony; Nachtman, Jane; Newsom, Charles Ray; Norbeck, Edwin; Onel, Yasar; Ozok, Ferhat; Sen, Sercan; Tan, Ping; Tiras, Emrah; Wetzel, James; Yetkin, Taylan; Yi, Kai; Barnett, Bruce Arnold; Blumenfeld, Barry; Bolognesi, Sara; Fehling, David; Giurgiu, Gavril; Gritsan, Andrei; Guo, Zijin; Hu, Guofan; Maksimovic, Petar; Rappoccio, Salvatore; Swartz, Morris; Whitbeck, Andrew; Baringer, Philip; Bean, Alice; Benelli, Gabriele; Kenny Iii, Raymond Patrick; Murray, Michael; Noonan, Daniel; Sanders, Stephen; Stringer, Robert; Tinti, Gemma; Wood, Jeffrey Scott; Zhukova, Victoria; Barfuss, Anne-Fleur; Bolton, Tim; Chakaberia, Irakli; Ivanov, Andrew; Khalil, Sadia; Makouski, Mikhail; Maravin, Yurii; Shrestha, Shruti; Svintradze, Irakli; Gronberg, Jeffrey; Lange, David; Wright, Douglas; Baden, Drew; Boutemeur, Madjid; Calvert, Brian; Eno, Sarah Catherine; Gomez, Jaime; Hadley, Nicholas John; Kellogg, Richard G; Kirn, Malina; Kolberg, Ted; Lu, Ying; Marionneau, Matthieu; Mignerey, Alice; Pedro, Kevin; Peterman, Alison; Skuja, Andris; Temple, Jeffrey; Tonjes, Marguerite; Tonwar, Suresh C; Twedt, Elizabeth; Apyan, Aram; Bauer, Gerry; Bendavid, Joshua; Busza, Wit; Butz, Erik; Cali, Ivan Amos; Chan, Matthew; Dutta, Valentina; Gomez Ceballos, Guillelmo; Goncharov, Maxim; Hahn, Kristan Allan; Kim, Yongsun; Klute, Markus; Krajczar, Krisztian; Luckey, Paul David; Ma, Teng; Nahn, Steve; Paus, Christoph; Ralph, Duncan; Roland, Christof; Roland, Gunther; Rudolph, Matthew; Stephans, George; Stöckli, Fabian; Sumorok, Konstanty; Sung, Kevin; Velicanu, Dragos; Wenger, Edward Allen; Wolf, Roger; Wyslouch, Bolek; Yang, Mingming; Yilmaz, Yetkin; Yoon, Sungho; Zanetti, Marco; Cooper, Seth; Dahmes, Bryan; De Benedetti, Abraham; Franzoni, Giovanni; Gude, Alexander; Kao, Shih-Chuan; Klapoetke, Kevin; Kubota, Yuichi; Mans, Jeremy; Pastika, Nathaniel; Rusack, Roger; Sasseville, Michael; Singovsky, Alexander; Tambe, Norbert; Turkewitz, Jared; Cremaldi, Lucien Marcus; Kroeger, Rob; Perera, Lalith; Rahmat, Rahmat; Sanders, David A; Avdeeva, Ekaterina; Bloom, Kenneth; Bose, Suvadeep; Butt, Jamila; Claes, Daniel R; Dominguez, Aaron; Eads, Michael; Keller, Jason; Kravchenko, Ilya; Lazo-Flores, Jose; Malbouisson, Helena; Malik, Sudhir; Snow, Gregory R; Godshalk, Andrew; Iashvili, Ia; Jain, Supriya; Kharchilava, Avto; Kumar, Ashish; Alverson, George; Barberis, Emanuela; Baumgartel, Darin; Chasco, Matthew; Haley, Joseph; Nash, David; Trocino, Daniele; Wood, Darien; Zhang, Jinzhong; Anastassov, Anton; Kubik, Andrew; Mucia, Nicholas; Odell, Nathaniel; Ofierzynski, Radoslaw Adrian; Pollack, Brian; Pozdnyakov, Andrey; Schmitt, Michael Henry; Stoynev, Stoyan; Velasco, Mayda; Won, Steven; Antonelli, Louis; Berry, Douglas; Brinkerhoff, Andrew; Chan, Kwok Ming; Hildreth, Michael; Jessop, Colin; Karmgard, Daniel John; Kolb, Jeff; Lannon, Kevin; Luo, Wuming; Lynch, Sean; Marinelli, Nancy; Morse, David Michael; Pearson, Tessa; Planer, Michael; Ruchti, Randy; Slaunwhite, Jason; Valls, Nil; Wayne, Mitchell; Wolf, Matthias; Bylsma, Ben; Durkin, Lloyd Stanley; Hill, Christopher; Hughes, Richard; Kotov, Khristian; Ling, Ta-Yung; Puigh, Darren; Rodenburg, Marissa; Vuosalo, Carl; Williams, Grayson; Winer, Brian L; Adam, Nadia; Berry, Edmund; Elmer, Peter; Gerbaudo, Davide; Halyo, Valerie; Hebda, Philip; Hegeman, Jeroen; Hunt, Adam; Jindal, Pratima; Lopes Pegna, David; Lujan, Paul; Marlow, Daniel; Medvedeva, Tatiana; Mooney, Michael; Olsen, James; Piroué, Pierre; Quan, Xiaohang; Raval, Amita; Safdi, Ben; Saka, Halil; Stickland, David; Tully, Christopher; Werner, Jeremy Scott; Zuranski, Andrzej; Brownson, Eric; Lopez, Angel; Mendez, Hector; Ramirez Vargas, Juan Eduardo; Alagoz, Enver; Barnes, Virgil E; Benedetti, Daniele; Bolla, Gino; Bortoletto, Daniela; De Mattia, Marco; Everett, Adam; Hu, Zhen; Jones, Matthew; Koybasi, Ozhan; Kress, Matthew; Laasanen, Alvin T; Leonardo, Nuno; Maroussov, Vassili; Merkel, Petra; Miller, David Harry; Neumeister, Norbert; Shipsey, Ian; Silvers, David; Svyatkovskiy, Alexey; Vidal Marono, Miguel; Yoo, Hwi Dong; Zablocki, Jakub; Zheng, Yu; Guragain, Samir; Parashar, Neeti; Adair, Antony; Boulahouache, Chaouki; Ecklund, Karl Matthew; Geurts, Frank JM; Li, Wei; Padley, Brian Paul; Redjimi, Radia; Roberts, Jay; Zabel, James; Betchart, Burton; Bodek, Arie; Chung, Yeon Sei; Covarelli, Roberto; de Barbaro, Pawel; Demina, Regina; Eshaq, Yossof; Ferbel, Thomas; Garcia-Bellido, Aran; Goldenzweig, Pablo; Han, Jiyeon; Harel, Amnon; Miner, Daniel Carl; Vishnevskiy, Dmitry; Zielinski, Marek; Bhatti, Anwar; Ciesielski, Robert; Demortier, Luc; Goulianos, Konstantin; Lungu, Gheorghe; Malik, Sarah; Mesropian, Christina; Arora, Sanjay; Barker, Anthony; Chou, John Paul; Contreras-Campana, Christian; Contreras-Campana, Emmanuel; Duggan, Daniel; Ferencek, Dinko; Gershtein, Yuri; Gray, Richard; Halkiadakis, Eva; Hidas, Dean; Lath, Amitabh; Panwalkar, Shruti; Park, Michael; Patel, Rishi; Rekovic, Vladimir; Robles, Jorge; Rose, Keith; Salur, Sevil; Schnetzer, Steve; Seitz, Claudia; Somalwar, Sunil; Stone, Robert; Thomas, Scott; Cerizza, Giordano; Hollingsworth, Matthew; Spanier, Stefan; Yang, Zong-Chang; York, Andrew; Eusebi, Ricardo; Flanagan, Will; Gilmore, Jason; Kamon, Teruki; Khotilovich, Vadim; Montalvo, Roy; Osipenkov, Ilya; Pakhotin, Yuriy; Perloff, Alexx; Roe, Jeffrey; Safonov, Alexei; Sakuma, Tai; Sengupta, Sinjini; Suarez, Indara; Tatarinov, Aysen; Toback, David; Akchurin, Nural; Damgov, Jordan; Dragoiu, Cosmin; Dudero, Phillip Russell; Jeong, Chiyoung; Kovitanggoon, Kittikul; Lee, Sung Won; Libeiro, Terence; Roh, Youn; Volobouev, Igor; Appelt, Eric; Delannoy, Andrés G; Florez, Carlos; Greene, Senta; Gurrola, Alfredo; Johns, Willard; Kurt, Pelin; Maguire, Charles; Melo, Andrew; Sharma, Monika; Sheldon, Paul; Snook, Benjamin; Tuo, Shengquan; Velkovska, Julia; Arenton, Michael Wayne; Balazs, Michael; Boutle, Sarah; Cox, Bradley; Francis, Brian; Goodell, Joseph; Hirosky, Robert; Ledovskoy, Alexander; Lin, Chuanzhe; Neu, Christopher; Wood, John; Gollapinni, Sowjanya; Harr, Robert; Karchin, Paul Edmund; Kottachchi Kankanamge Don, Chamath; Lamichhane, Pramod; Sakharov, Alexandre; Anderson, Michael; Belknap, Donald; Borrello, Laura; Carlsmith, Duncan; Cepeda, Maria; Dasu, Sridhara; Friis, Evan; Gray, Lindsey; Grogg, Kira Suzanne; Grothe, Monika; Hall-Wilton, Richard; Herndon, Matthew; Hervé, Alain; Klabbers, Pamela; Klukas, Jeffrey; Lanaro, Armando; Lazaridis, Christos; Leonard, Jessica; Loveless, Richard; Mohapatra, Ajit; Ojalvo, Isabel; Palmonari, Francesco; Pierro, Giuseppe Antonio; Ross, Ian; Savin, Alexander; Smith, Wesley H; Swanson, Joshua

    2013-05-21

    A search is presented for free heavy long-lived fractionally charged particles produced in pp collisions at $\\sqrt{s}$ = 7 TeV. The data sample was recorded by the CMS detector at the LHC and corresponds to an integrated luminosity of 5.0 inverse femtobarns. Candidate fractionally charged particles are identified by selecting tracks with associated low charge measurements in the silicon tracking detector. Observations are found to be consistent with expectations for background processes. The results of the search are used to set upper limits on the cross section for pair production of fractionally charged, massive spin-1/2 particles that are neutral under SU(3)$_C$ and SU(2)$_L$. We exclude at 95% confidence level such particles with electric charge ±2e/3 with masses below 310 GeV, and those with charge ±e/3 with masses below 140 GeV.

  3. 4. Workshop on heavy charged particles in biology and medicine in connection with the XV PTCOG meeting. Book of abstracts

    International Nuclear Information System (INIS)

    Kraft, G.

    1991-09-01

    The fourth workshop on heavy charged particles in biology and medicine is held after a long break of 4 years. For the biological response of cells or subcellar objects, the experiment is still the only source of safe information. A large and still growing community performs these experiments as it is demonstrated by the numerous presentations of this workshop. This research has been extended to a more molecular level like DNA as well as to completly different systems like the cellular membran. There again, new and surprising results have been found. Finally, the problems of radiobiological research has stimulated atomic physicists to reconsider and to measure the emission of electrons in heavy ion-atom collisions. These experiments indicate that the conventional understanding of track formation has to be revised too. (orig./VHE)

  4. A nomogram for predicting distant brain failure in patients treated with gamma knife stereotactic radiosurgery without whole brain radiotherapy

    Science.gov (United States)

    Ayala-Peacock, Diandra N.; Peiffer, Ann M.; Lucas, John T.; Isom, Scott; Kuremsky, J. Griff; Urbanic, James J.; Bourland, J. Daniel; Laxton, Adrian W.; Tatter, Stephen B.; Shaw, Edward G.; Chan, Michael D.

    2014-01-01

    Background We review our single institution experience to determine predictive factors for early and delayed distant brain failure (DBF) after radiosurgery without whole brain radiotherapy (WBRT) for brain metastases. Materials and methods Between January 2000 and December 2010, a total of 464 patients were treated with Gamma Knife stereotactic radiosurgery (SRS) without WBRT for primary management of newly diagnosed brain metastases. Histology, systemic disease, RPA class, and number of metastases were evaluated as possible predictors of DBF rate. DBF rates were determined by serial MRI. Kaplan–Meier method was used to estimate rate of DBF. Multivariate analysis was performed using Cox Proportional Hazard regression. Results Median number of lesions treated was 1 (range 1–13). Median time to DBF was 4.9 months. Twenty-seven percent of patients ultimately required WBRT with median time to WBRT of 5.6 months. Progressive systemic disease (χ2= 16.748, P < .001), number of metastases at SRS (χ2 = 27.216, P < .001), discovery of new metastases at time of SRS (χ2 = 9.197, P < .01), and histology (χ2 = 12.819, P < .07) were factors that predicted for earlier time to distant failure. High risk histologic subtypes (melanoma, her2 negative breast, χ2 = 11.020, P < .001) and low risk subtypes (her2 + breast, χ2 = 11.343, P < .001) were identified. Progressive systemic disease (χ2 = 9.549, P < .01), number of brain metastases (χ2 = 16.953, P < .001), minimum SRS dose (χ2 = 21.609, P < .001), and widespread metastatic disease (χ2 = 29.396, P < .001) were predictive of shorter time to WBRT. Conclusion Systemic disease, number of metastases, and histology are factors that predict distant failure rate after primary radiosurgical management of brain metastases. PMID:24558022

  5. Frame-based and frameless stereotactic radiosurgery for intracranial and extracranial tumors

    International Nuclear Information System (INIS)

    Petrovich, Z.; Cheng Yu

    2003-01-01

    During the past 10 years stereotactic frame-based radiosurgery (SRS) emerged as an important treatment modality in the management of selected intracranial lesions. More recently, frameless SRS has extended the potential of ibis treatment to include lesions virtually in any site of the body. Many thousands of patients are being treated annually with frame-based SRS limited to the cranial cavity. A total of 180,222 patients were treated to December 2001 with gamma knife (GK) and, very likely, a similar number was treated with various linear accelerator based SRS systems. Frameless SRS has been performed uncommonly until cyber knife (CK) became available. Over 3,000 patients were treated with CK in the US and Japan. This included patients treated for extracranial lesions. Treatment results in patients treated with GK at University of Southern California (USC) will be presented. From 1994 to 2002, a total of 1,126 patients received GK at USC for various indications. Since metastatic tumor constituted the largest (42.4%) diagnostic category treated, the outcome in this group is specifically discussed. The overall median survival was 9.2 months. The median survival was 8.3, 9.0, 17 and 12 months, for melanoma, lung cancer, breast cancer and renal cell carcinoma, respectively. In multivariate analysis Karnofsky's performance status (70 vs. >70), status of systemic disease (inactive vs. active), tumor histology and total intracranial tumor volume were the only important factors predictive of survival, p=0.0001. Cause of death was found to be due to CNS problems in about 25% of patients with a diagnosis other than melanoma, while it was 42% in those with melanoma. GK SRS was given on an outpatient basis and was very well tolerated by the patients. Symptomatic focal radionecrosis requiring craniotomy for its removal was noted in <5% of patients. An excellent palliative benefit was obtained in nearly all patients. The treatment was compatible with a good quality of life

  6. Hematological Toxicity After Robotic Stereotactic Body Radiosurgery for Treatment of Metastatic Gynecologic Malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Kunos, Charles A., E-mail: charles.kunos@UHhospitals.org [Department of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States); Debernardo, Robert [Department of Obstetrics and Gynecology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States); Radivoyevitch, Tomas [Department of Epidemiology and Biostatistics, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States); Fabien, Jeffrey; Dobbins, Donald C.; Zhang Yuxia; Brindle, James [Department of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University School of Medicine, Cleveland, Ohio (United States)

    2012-09-01

    Purpose: To evaluate hematological toxicity after robotic stereotactic body radiosurgery (SBRT) for treatment of women with metastatic abdominopelvic gynecologic malignancies. Methods and Materials: A total of 61 women with stage IV gynecologic malignancies treated with abdominopelvic SBRT were analyzed after ablative radiation (2400 cGy/3 divided consecutive daily doses) delivered by a robotic-armed Cyberknife SBRT system. Abdominopelvic bone marrow was identified using computed tomography-guided contouring. Fatigue and hematologic toxicities were graded by retrospective assignment of common toxicity criteria for adverse events (version 4.0). Bone marrow volume receiving 1000 cGy (V10) was tested for association with post-therapy (median 32 days [25%-75% quartile, 28-45 days]) white- or red-cell counts, hemoglobin levels, and platelet counts as marrow toxicity surrogates. Results: In all, 61 women undergoing abdominopelvic SBRT had a median bone marrow V10 of 2% (25%-75% quartile: 0%-8%). Fifty-seven (93%) of 61 women had received at least 1 pre-SBRT marrow-taxing chemotherapy regimen for metastatic disease. Bone marrow V10 did not associate with hematological adverse events. In all, 15 grade 2 (25%) and 2 grade 3 (3%) fatigue symptoms were self-reported among the 61 women within the first 10 days post-therapy, with fatigue resolved spontaneously in all 17 women by 30 days post-therapy. Neutropenia was not observed. Three (5%) women had a grade 1 drop in hemoglobin level to <10.0 g/dL. Single grade 1, 2, and 3 thrombocytopenias were documented in 3 women. Conclusions: Abdominopelvic SBRT provided ablative radiation dose to cancer targets without increased bone marrow toxicity. Abdominopelvic SBRT for metastatic gynecologic malignancies warrants further study.

  7. Phase II clinical trial of robotic stereotactic body radiosurgery for metastatic gynecologic malignancies

    Directory of Open Access Journals (Sweden)

    Charles eKunos

    2012-12-01

    Full Text Available Background Recurrent gynecologic cancers are often difficult to manage without significant morbidity. We conducted a phase II study to assess the safety and the efficacy of ablative robotic stereotactic body radiosurgery (SBRT in women with metastatic gynecologic cancers. Methods A total of 50 patients with recurrent gynecologic cancer who had single or multiple (≤4 metastases underwent robotic-armed Cyberknife SBRT (24Gy/3 daily doses. Toxicities were graded prospectively by common toxicity criteria for adverse events (version 4.0. SBRT target responses were recorded following RECIST criteria (version 1.0. Rates of clinical benefit for SBRT and non-radiosurgical disease relapse were calculated. Disease-free and overall survivals were estimated by the Kaplan-Meier method and the Cox proportional hazards model was used to control for prognostic variables.Findings SBRT was safely delivered, with 49 (98% of 50 patients completing three prescribed fractions. The most frequent grade 2 or higher adverse events attributed to SBRT included fatigue (16%, nausea (8% and diarrhea (4%. One (2% grade 4 hyperbilirubinemia occurred. SBRT target response was 96% (48 of 50 patients. A 6-month clinical benefit was recorded in 34 (68% [95% CI, 53.2, 80.1] patients. No SBRT-targeted disease progressed. Non-radiosurgical disease relapse occurred in 31 (62% patients. Median disease-free survival was 7.8 months (95% CI, 4.0, 11.6. Median overall survival was 20.2 months (95% CI, 10.9, 29.5.Interpretation SBRT safely controlled metastatic gynecologic cancer targets. Given an observed high rate of non-radiosurgical disease relapse, a phase I trial assessing co-administration of SBRT and cytotoxic chemotherapy is underway.Funding Case Comprehensive Cancer Center

  8. Phase II Clinical Trial of Robotic Stereotactic Body Radiosurgery for Metastatic Gynecologic Malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Kunos, Charles A.; Brindle, James [Department of Radiation Oncology, University Hospitals Case Medical Center and Case Western Reserve University, School of Medicine, Cleveland, OH (United States); Waggoner, Steven; Zanotti, Kristine; Resnick, Kimberly; Fusco, Nancy; Adams, Ramon; Debernardo, Robert, E-mail: charles.kunos@uhhospitals.org [Division of Gynecologic Oncology, Department of Obstetrics and Gynecology, University Hospitals Case Medical Center and Case Western Reserve University, School of Medicine, Cleveland, OH (United States)

    2012-12-05

    Background: Recurrent gynecologic cancers are often difficult to manage without significant morbidity. We conducted a phase II study to assess the safety and the efficacy of ablative robotic stereotactic body radiosurgery (SBRT) in women with metastatic gynecologic cancers. Methods: A total of 50 patients with recurrent gynecologic cancer who had single or multiple (≤4) metastases underwent robotic-armed Cyberknife SBRT (24Gy/3 daily doses). Toxicities were graded prospectively by common toxicity criteria for adverse events (version 4.0). SBRT target responses were recorded following RECIST criteria (version 1.0). Rates of clinical benefit for SBRT and non-radiosurgical disease relapse were calculated. Disease-free and overall survivals were estimated by the Kaplan–Meier method and the Cox proportional hazards model was used to control for prognostic variables. Findings: SBRT was safely delivered, with 49 (98%) of 50 patients completing three prescribed fractions. The most frequent grade 2 or higher adverse events attributed to SBRT included fatigue (16%), nausea (8%), and diarrhea (4%). One (2%) grade four hyperbilirubinemia occurred. SBRT target response was 96% (48 of 50 patients). A 6-month clinical benefit was recorded in 34 [68% (95% CI, 53.2, 80.1)] patients. No SBRT targeted disease progressed. Non-radiosurgical disease relapse occurred in 31 (62%) patients. Median disease-free survival was 7.8 months (95% CI, 4.0, 11.6). Median overall survival was 20.2 months (95% CI, 10.9, 29.5). Interpretation: SBRT safely controlled metastatic gynecologic cancer targets. Given an observed high rate of non-radiosurgical disease relapse, a phase I trial assessing co-administration of SBRT and cytotoxic chemotherapy is underway. Funding: Case Comprehensive Cancer Center.

  9. Hematological Toxicity After Robotic Stereotactic Body Radiosurgery for Treatment of Metastatic Gynecologic Malignancies

    International Nuclear Information System (INIS)

    Kunos, Charles A.; Debernardo, Robert; Radivoyevitch, Tomas; Fabien, Jeffrey; Dobbins, Donald C.; Zhang Yuxia; Brindle, James

    2012-01-01

    Purpose: To evaluate hematological toxicity after robotic stereotactic body radiosurgery (SBRT) for treatment of women with metastatic abdominopelvic gynecologic malignancies. Methods and Materials: A total of 61 women with stage IV gynecologic malignancies treated with abdominopelvic SBRT were analyzed after ablative radiation (2400 cGy/3 divided consecutive daily doses) delivered by a robotic-armed Cyberknife SBRT system. Abdominopelvic bone marrow was identified using computed tomography-guided contouring. Fatigue and hematologic toxicities were graded by retrospective assignment of common toxicity criteria for adverse events (version 4.0). Bone marrow volume receiving 1000 cGy (V10) was tested for association with post-therapy (median 32 days [25%-75% quartile, 28-45 days]) white- or red-cell counts, hemoglobin levels, and platelet counts as marrow toxicity surrogates. Results: In all, 61 women undergoing abdominopelvic SBRT had a median bone marrow V10 of 2% (25%-75% quartile: 0%-8%). Fifty-seven (93%) of 61 women had received at least 1 pre-SBRT marrow-taxing chemotherapy regimen for metastatic disease. Bone marrow V10 did not associate with hematological adverse events. In all, 15 grade 2 (25%) and 2 grade 3 (3%) fatigue symptoms were self-reported among the 61 women within the first 10 days post-therapy, with fatigue resolved spontaneously in all 17 women by 30 days post-therapy. Neutropenia was not observed. Three (5%) women had a grade 1 drop in hemoglobin level to <10.0 g/dL. Single grade 1, 2, and 3 thrombocytopenias were documented in 3 women. Conclusions: Abdominopelvic SBRT provided ablative radiation dose to cancer targets without increased bone marrow toxicity. Abdominopelvic SBRT for metastatic gynecologic malignancies warrants further study.

  10. Phase II Clinical Trial of Robotic Stereotactic Body Radiosurgery for Metastatic Gynecologic Malignancies

    International Nuclear Information System (INIS)

    Kunos, Charles A.; Brindle, James; Waggoner, Steven; Zanotti, Kristine; Resnick, Kimberly; Fusco, Nancy; Adams, Ramon; Debernardo, Robert

    2012-01-01

    Background: Recurrent gynecologic cancers are often difficult to manage without significant morbidity. We conducted a phase II study to assess the safety and the efficacy of ablative robotic stereotactic body radiosurgery (SBRT) in women with metastatic gynecologic cancers. Methods: A total of 50 patients with recurrent gynecologic cancer who had single or multiple (≤4) metastases underwent robotic-armed Cyberknife SBRT (24Gy/3 daily doses). Toxicities were graded prospectively by common toxicity criteria for adverse events (version 4.0). SBRT target responses were recorded following RECIST criteria (version 1.0). Rates of clinical benefit for SBRT and non-radiosurgical disease relapse were calculated. Disease-free and overall survivals were estimated by the Kaplan–Meier method and the Cox proportional hazards model was used to control for prognostic variables. Findings: SBRT was safely delivered, with 49 (98%) of 50 patients completing three prescribed fractions. The most frequent grade 2 or higher adverse events attributed to SBRT included fatigue (16%), nausea (8%), and diarrhea (4%). One (2%) grade four hyperbilirubinemia occurred. SBRT target response was 96% (48 of 50 patients). A 6-month clinical benefit was recorded in 34 [68% (95% CI, 53.2, 80.1)] patients. No SBRT targeted disease progressed. Non-radiosurgical disease relapse occurred in 31 (62%) patients. Median disease-free survival was 7.8 months (95% CI, 4.0, 11.6). Median overall survival was 20.2 months (95% CI, 10.9, 29.5). Interpretation: SBRT safely controlled metastatic gynecologic cancer targets. Given an observed high rate of non-radiosurgical disease relapse, a phase I trial assessing co-administration of SBRT and cytotoxic chemotherapy is underway. Funding: Case Comprehensive Cancer Center.

  11. Electromagnetic radiation of charged particles in stochastic motion

    Energy Technology Data Exchange (ETDEWEB)

    Harko, Tiberiu [Babes-Bolyai University, Department of Physics, Cluj-Napoca (Romania); University College London, Department of Mathematics, London (United Kingdom); Mocanu, Gabriela [Astronomical Institute of the Romanian Academy, Cluj-Napoca (Romania)

    2016-03-15

    The study of the Brownian motion of a charged particle in electric and magnetic fields has many important applications in plasma and heavy ions physics, as well as in astrophysics. In the present paper we consider the electromagnetic radiation properties of a charged non-relativistic particle in the presence of electric and magnetic fields, of an exterior non-electromagnetic potential, and of a friction and stochastic force, respectively. We describe the motion of the charged particle by a Langevin and generalized Langevin type stochastic differential equation. We investigate in detail the cases of the Brownian motion with or without memory in a constant electric field, in the presence of an external harmonic potential, and of a constant magnetic field. In all cases the corresponding Langevin equations are solved numerically, and a full description of the spectrum of the emitted radiation and of the physical properties of the motion is obtained. The power spectral density of the emitted power is also obtained for each case, and, for all considered oscillating systems, it shows the presence of peaks, corresponding to certain intervals of the frequency. (orig.)

  12. Track-structure simulations for charged particles.

    Science.gov (United States)

    Dingfelder, Michael

    2012-11-01

    Monte Carlo track-structure simulations provide a detailed and accurate picture of radiation transport of charged particles through condensed matter of biological interest. Liquid water serves as a surrogate for soft tissue and is used in most Monte Carlo track-structure codes. Basic theories of radiation transport and track-structure simulations are discussed and differences compared to condensed history codes highlighted. Interaction cross sections for electrons, protons, alpha particles, and light and heavy ions are required input data for track-structure simulations. Different calculation methods, including the plane-wave Born approximation, the dielectric theory, and semi-empirical approaches are presented using liquid water as a target. Low-energy electron transport and light ion transport are discussed as areas of special interest.

  13. Plasma polymer-functionalized silica particles for heavy metals removal.

    Science.gov (United States)

    Akhavan, Behnam; Jarvis, Karyn; Majewski, Peter

    2015-02-25

    Highly negatively charged particles were fabricated via an innovative plasma-assisted approach for the removal of heavy metal ions. Thiophene plasma polymerization was used to deposit sulfur-rich films onto silica particles followed by the introduction of oxidized sulfur functionalities, such as sulfonate and sulfonic acid, via water-plasma treatments. Surface chemistry analyses were conducted by X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectroscopy. Electrokinetic measurements quantified the zeta potentials and isoelectric points (IEPs) of modified particles and indicated significant decreases of zeta potentials and IEPs upon plasma modification of particles. Plasma polymerized thiophene-coated particles treated with water plasma for 10 min exhibited an IEP of less than 3.5. The effectiveness of developed surfaces in the adsorption of heavy metal ions was demonstrated through copper (Cu) and zinc (Zn) removal experiments. The removal of metal ions was examined through changing initial pH of solution, removal time, and mass of particles. Increasing the water plasma treatment time to 20 min significantly increased the metal removal efficiency (MRE) of modified particles, whereas further increasing the plasma treatment time reduced the MRE due to the influence of an ablation mechanism. The developed particulate surfaces were capable of removing more than 96.7% of both Cu and Zn ions in 1 h. The combination of plasma polymerization and oxidative plasma treatment is an effective method for the fabrication of new adsorbents for the removal of heavy metals.

  14. Stereotactic radiotherapy following surgery for brain metastasis: Predictive factors for local control and radionecrosis.

    Science.gov (United States)

    Doré, M; Martin, S; Delpon, G; Clément, K; Campion, L; Thillays, F

    2017-02-01

    To evaluate local control and adverse effects after postoperative hypofractionated stereotactic radiosurgery in patients with brain metastasis. We reviewed patients who had hypofractionated stereotactic radiosurgery (7.7Gy×3 prescribed to the 70% isodose line, with 2mm planning target volume margin) following resection from March 2008 to January 2014. The primary endpoint was local failure defined as recurrence within the surgical cavity. Secondary endpoints were distant failure rates and the occurrence of radionecrosis. Out of 95 patients, 39.2% had metastatic lesions from a non-small cell lung cancer primary tumour. The median Graded Prognostic Assessment score was 3 (48% of patients). One-year local control rates were 84%. Factors associated with improved local control were no cavity enhancement on pre-radiation MRI (P<0.00001), planning target volume less than 12cm 3 (P=0.005), Graded Prognostic Assessment score 2 or above (P=0.009). One-year distant cerebral control rates were 56%. Thirty-three percent of patients received whole brain radiation therapy. Histologically proven radionecrosis of brain tissue occurred in 7.2% of cases. The size of the preoperative lesion and the volume of healthy brain tissue receiving 21Gy (V 21 ) were both predictive of the incidence of radionecrosis (P=0.010 and 0.036, respectively). Adjuvant hypofractionated stereotactic radiosurgery to the postoperative cavity in patients with brain metastases results in excellent local control in selected patients, helps delay the use of whole brain radiation, and is associated with a relatively low risk of radionecrosis. Copyright © 2016 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  15. Effects of heavy-ion radiosurgery on the hemopoietic function of the silkworm Bombyx mori

    Energy Technology Data Exchange (ETDEWEB)

    Tu, Zhen-Li; Kobayashi, Yasuhiko; Watanabe, Hiroshi; Yamamoto, Kazuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Kiguchi, Kenji [SHINSHU Univ., Ueda, Nagano (Japan). Faculty of Textile Science and Technology

    2002-09-01

    To study the effects of heavy-ion radiosurgery on the hemopoietic function of a silkworm, hemopoietic organs of larvae were locally irradiated with carbon-ion beams, and the changes in the hemocyte density and in the hemocyte function were investigated. When the larvae were irradiated by 50 Gy to 300 Gy carbon ions on the 3rd day of the 4th instar, the hemocyte densities did not change for a while, though they gradually increased at a later stage, but were finally still significantly lower than those of unirradiated controls. The hemocyte densities of the larvae irradiated at different developmental stages showed suppressed increments, and carbon-ion irradiation given to larvae at early stages compared to the later stages had a significant suppressive effect on the hemocyte densities. On unilateral irradiated larvae a hemocyte intermediate increment between those of bilateral irradiated larvae and unirradiated controls was observed. The percentage of dead hemocytes was obviously higher for irradiated larvae than unirradiated controls during the later 5th instar. Thus, it is evident that carbon-ion radiosurgery on hemopoietic organs of silkworm induced not only a quantitative change, but also a qualitative change in the hemocytes. (author)

  16. Heavy cosmic ions with charge Z = 3q-40 and their biological implications

    International Nuclear Information System (INIS)

    Hasegan, D.; Dudkin, E.V.; Marenny, M.A.

    1979-01-01

    Heavy cosmic ions were studied by plastic detectors flown in cosmic space aboard the artificial Earth satellites COSMOS 690, 782 and 936. Charge spectra in the range of Z = 3q-40 of cosmic nuclei having energy E >= 1 GeV/nucleon are presented. LET spectra of heavy cosmic ions were measured in these experiments, as well as the LET variation inside the stacks of plastic detectors. The variation of the irreversible inactivation cross sections and the Fractional Cell Loss with depth are derived. Three-dimensional energy deposition around the trajectories of the particles, in the studied ranges of charges and energies, is computed using Katz's model. (author)

  17. Analyses of multi-irradiation film for system alignments in stereotactic radiotherapy (SRT) and radiosurgery (SRS)

    International Nuclear Information System (INIS)

    Jen-San Tsai

    1996-01-01

    In stereotactic radiosurgery, a seven-irradiation film was used to define any discrepancy between the beam and target centres. A mathematical model based on the linac alignment and target set-up was developed to diagnose the discrepancies of the seven-irradiation film between the beam and simulation target centres. From the measured data of the multi-irradiation film, this mathematical model leads to five parameters in seven equations. Twin computer codes were employed to solve the five parameters from the seven equations. By feeding the discrepancy data into the two computer codes, the sources of the target-to-beam discrepancy were revealed. From these decoded sources, the target coordinates were adjusted and then the seven-irradiation film procedure was repeated. This discrepancy thus obtained was found to be drastically reduced. Some decoded parameters were consistently verified by direct measurements. This demonstrates that the present mathematical model and computer code do reveal the causes of the target-to-beam misalignment and gantry sag. In a further effort to test the feasibility of the mathematical model and the computer codes, the target's lateral coordinate was deliberately offset by 1.5 mm and then another seven-irradiation film was taken. By inserting these discrepancies into the computer codes, it was found that the deviation was consistent with the intentional offset. In addition, the mathematical model and computer codes are applicable to any multi-irradiation technique. (author)

  18. Hearing Outcomes After Stereotactic Radiosurgery for Unilateral Intracanalicular Vestibular Schwannomas: Implication of Transient Volume Expansion

    International Nuclear Information System (INIS)

    Kim, Young-Hoon; Kim, Dong Gyu; Han, Jung Ho; Chung, Hyun-Tai; Kim, In Kyung; Song, Sang Woo; Park, Jeong-Hoon; Kim, Jin Wook; Kim, Yong Hwy; Park, Chul-Kee; Kim, Chae-Yong; Paek, Sun Ha; Jung, Hee-Won

    2013-01-01

    Purpose: We evaluated the prognostic factors for hearing outcomes after stereotactic radiosurgery (SRS) for unilateral sporadic intracanalicular vestibular schwannomas (IC-VSs) as a clinical homogeneous group of VSs. Methods and Materials: Sixty consecutive patients with unilateral sporadic IC-VSs, defined as tumors in the internal acoustic canal, and serviceable hearing (Gardner-Roberson grade 1 or 2) were treated with SRS as an initial treatment. The mean tumor volume was 0.34 ± 0.03 cm 3 (range, 0.03-1.00 cm 3 ), and the mean marginal dose was 12.2 ± 0.1 Gy (range, 11.5-13.0 Gy). The median follow-up duration was 62 months (range, 36-141 months). Results: The actuarial rates of serviceable hearing preservation were 70%, 63%, and 55% at 1, 2, and 5 years after SRS, respectively. In multivariate analysis, transient volume expansion of ≥20% from initial tumor size was a statistically significant risk factor for loss of serviceable hearing and hearing deterioration (increase of pure tone average ≥20 dB) (odds ratio = 7.638; 95% confidence interval, 2.317-25.181; P=.001 and odds ratio = 3.507; 95% confidence interval, 1.228-10.018; P=.019, respectively). The cochlear radiation dose did not reach statistical significance. Conclusions: Transient volume expansion after SRS for VSs seems to be correlated with hearing deterioration when defined properly in a clinically homogeneous group of patients.

  19. The rationale and technique of staged-volume arteriovenous malformation radiosurgery

    International Nuclear Information System (INIS)

    Pollock, Bruce E.; Kline, Robert W.; Stafford, Scott L.; Foote, Robert L.; Schomberg, Paula J.

    2000-01-01

    Purpose: Stereotactic radiosurgery is an effective management strategy for properly selected arteriovenous malformation (AVM) patients. However, the risk of postradiosurgical radiation-related injury generally limits this procedure to patients with AVMs of an average diameter of 3 cm or less. Radiosurgery of large AVMs in a planned staged fashion was undertaken to limit the radiation exposure to the surrounding normal brain. Methods and Materials: Between April 1997 and December 1999, 10 patients with a median AVM volume of 17.4 cm 3 (range, 7.4-53.3 cm 3 ) underwent staged-volume radiosurgery (23 procedures). At the first radiosurgical procedure, the total volume of the AVM is estimated and a dose plan calculated that covers 10 cm 3 -15 cm 3 , or one-half the nidus volume if the AVM is critically located (brainstem, thalamus, or basal ganglia). At 6-month intervals thereafter, radiosurgery was repeated to different portions of the AVM with the previous dose plan(s) being re-created utilizing intracranial landmarks to minimize radiation overlap. Radiosurgical procedures were continued until the entire malformation has been irradiated. Results: The radiation dosimetry of staged-volume AVM radiosurgery was compared to hypothetical single-session procedures for the 10 patients. Staged-volume radiosurgery decreased the 12-Gy volume by an average of 11.1% (range, 4.9-21%) (p < 0.001). The non-AVM 12-Gy volume was reduced by an average of 27.2% (range, 12.5-51.3%) (p < 0.001). Discussion: Staged-volume radiosurgery of large AVMs results in less radiation exposure to the adjacent brain. Further follow-up is needed to determine whether this technique provides a high rate of AVM obliteration while maintaining an acceptable rate of radiation-related complications

  20. Study of the angular correlation between heavy-flavour decay electrons and charged unidentified particles in pp and p-Pb collisions with ALICE

    CERN Document Server

    Pereira De Oliveira Filho, Elienos

    The aim of relativistic heavy-ion collisions is to investigate the properties of the Quark-Gluon Plasma (QGP) phase, that is achieved at high-enough temperatures and/or densities. In this context, light on heavy-ion collisions (e. g. p-Pb) are used to assess Cold Nuclear Matter effects (CNM), while elementary hadronic collisions (e. g. proton-proton) provide tests for QCD (Quantum Chromodynamics) based calculations and baseline for studies with heavy- ions. Heavy quarks, i. e. charm and beauty, are very convenient in the characterization of the QGP. They are produced via initial hard parton-parton scatterings at the early stages of the collision and, therefore, they are a self-generated probe for the system created in the reaction. In this work the angular correlation between electrons from heavy-flavour hadron decays and charged particles was studied in pp (2.76 and 7 TeV) and p-Pb (5.02 TeV) collisions at the CERN Large Hadron Collider, using the ALICE detector. The correlation strengths were evaluated as a...

  1. Constraints on dark matter particles charged under a hidden gauge group from primordial black holes

    International Nuclear Information System (INIS)

    Dai, De-Chang; Stojkovic, Dejan; Freese, Katherine

    2009-01-01

    In order to accommodate increasingly tighter observational constraints on dark matter, several models have been proposed recently in which dark matter particles are charged under some hidden gauge group. Hidden gauge charges are invisible for the standard model particles, hence such scenarios are very difficult to constrain directly. However black holes are sensitive to all gauge charges, whether they belong to the standard model or not. Here, we examine the constraints on the possible values of the dark matter particle mass and hidden gauge charge from the evolution of primordial black holes. We find that the existence of the primordial black holes with reasonable mass is incompatible with dark matter particles whose charge to mass ratio is of the order of one. For dark matter particles whose charge to mass ratio is much less than one, we are able to exclude only heavy dark matter in the mass range of 10 11 GeV–10 16 GeV. Finally, for dark matter particles whose charge to mass ratio is much greater than one, there are no useful limits coming from primordial black holes

  2. Direct search for pair production of heavy stable charged particles in Z decays

    International Nuclear Information System (INIS)

    Soderstrom, E.; McKenna, J.A.; Abrams, G.S.; Adolphsen, C.E.; Averill, D.; Ballam, J.; Barish, B.C.; Barklow, T.; Barnett, B.A.; Bartelt, J.; Bethke, S.; Blockus, D.; Bonvicini, G.; Boyarski, A.; Brabson, B.; Breakstone, A.; Bulos, F.; Burchat, P.R.; Burke, D.L.; Cence, R.J.; Chapman, J.; Chmeissani, M.; Cords, D.; Coupal, D.P.; Dauncey, P.; DeStaebler, H.C.; Dorfan, D.E.; Dorfan, J.M.; Drewer, D.C.; Elia, R.; Feldman, G.J.; Fernandes, D.; Field, R.C.; Ford, W.T.; Fordham, C.; Frey, R.; Fujino, D.; Gan, K.K.; Gero, E.; Gidal, G.; Glanzman, T.; Goldhaber, G.; Gomez Cadenas, J.J.; Gratta, G.; Grindhammer, G.; Grosse-Wiesmann, P.; Hanson, G.; Harr, R.; Harral, B.; Harris, F.A.; Hawkes, C.M.; Hayes, K.; Hearty, C.; Heusch, C.A.; Hildreth, M.D.; Himel, T.; Hinshaw, D.A.; Hong, S.J.; Hutchinson, D.; Hylen, J.; Innes, W.R.; Jacobsen, R.G.; Jaros, J.A.; Jung, C.K.; Kadyk, J.A.; Kent, J.; King, M.; Koetke, D.S.; Komamiya, S.; Koska, W.; Kowalski, L.A.; Kozanecki, W.; Kral, J.F.; Kuhlen, M.; Labarga, L.; Lankford, A.J.; Larsen, R.R.; Le Diberder, F.; Levi, M.E.; Litke, A.M.; Lou, X.C.; Lueth, V.; Matthews, J.A.J.; Mattison, T.; Milliken, B.D.; Moffeit, K.C.; Munger, C.T.; Murray, W.N.; Nash, J.; Ogren, H.; O'Shaughnessy, K.F.; Parker, S.I.; Peck, C.; Perl, M.L.; Petradza, M.; Pitthan, R.; Porter, F.C.; Rankin, P.; Riles, K.; Rouse, F.R.; Rust, D.R.; Sadrozinski, H.F.W.; Schaad, M.W.; Schumm, B.A.; Seiden, A.; Smith, J.G.; Snyder, A.; Stoker, D.P.; Stroynowski, R.; Swartz, M.; Thun, R.; Trilling, G.H.; Van Kooten, R.; Voruganti, P.; Wagner, S.R.; Watson, S.; Weber, P.; Weinstein, A.J.; Weir, A.J.; Wicklund, E.; Woods, M.; Wu, D.Y.; Yurko, M.; Zaccardelli, C.; von Zanthie, C.

    1990-01-01

    A search for pair production of stable charged particles from Z decay has been performed with the Mark II detector at the SLAC Linear Collider. Particle masses are determined from momentum, ionization energy loss, and time-of-flight measurements. A limit excluding pair production of stable fourth-generation charged leptons and stable mirror fermions with masses between the muon mass and 36.3 GeV/c 2 is set at the 95% confidence level. Pair production of stable supersymmetric scalar leptons with masses between the muon mass and 32.6 GeV/c 2 is also excluded

  3. Therapeutic cranial nerve irradiation: results from a multi-center dose response study of radiosurgery for trigeminal neuralgia

    Energy Technology Data Exchange (ETDEWEB)

    Kondziolka, D; Flickinger, J; Lunsford, L D; Young, R; Vermeulen, S; Duma, C; Jacques, D B; Rand, R; Regis, J; Peragut, J C; Epstein, M H; Lindquist, C

    1995-07-01

    Purpose/Objective: We performed a multi-institution study to evaluate the technique, dose-selection parameters, and results of gamma knife stereotactic radiosurgery in the management of trigeminal neuralgia. We hypothesized that MRI-stereotactic targeting of the trigeminal nerve and irradiation with a single 4 mm isocenter, 2-4 mm anterior to the brainstem, could be a safe and effective treatment for this disorder. Materials and Methods: Fifty patients at five centers had radiosurgery using a single 4 mm isocenter targeted at the root entry zone. All patients had typical trigeminal neuralgia. The mean patient age was 70 years, (range, 40-87). Thirty-two patients had undergone prior surgery, and the mean number of procedures performed was 2.8 (range, 1-7). Eighteen patients (36%) had not had prior surgery before radiosurgery. Maximum radiosurgery doses included 60 Gy (n=8), 65 Gy (n=3), 70 Gy (n=27), 75 Gy (n=2), 80 Gy (n=6) and 90 Gy (n=4). All patients were discharged within 24 hours and were studied in regard to the degree of pain relief, latency interval to pain relief, sensory loss, and the need for further therapy. Mean follow-up after radiosurgery was 9.2 months (range, 2-26 months). Results: At last follow-up, 25 patients (50%) had excellent control (pain-free), 17 (34%) had good control (50-90% relief), and 8 (16%) had failed (see Figure). The median time to pain relief was one month. We identified an actuarial response rate of 53% for complete pain relief at seven months, and 93% for pain reduction (50-100% relief). At 18 months, these results declined to 48% and 77% respectively. A significantly greater proportion of patients receiving a radiosurgery maximum dose of {>=} 70 Gy achieved complete pain relief (63% vs. 18%) and >50% pain reduction (96% vs. 80%) than those with doses <70 Gy. Patients without prior surgery had significantly better outcomes in univariate testing. Three patients (6%) developed increased facial paresthesiae after radiosurgery

  4. Therapeutic cranial nerve irradiation: results from a multi-center dose response study of radiosurgery for trigeminal neuralgia

    International Nuclear Information System (INIS)

    Kondziolka, D.; Flickinger, J.; Lunsford, L.D.; Young, R.; Vermeulen, S.; Duma, C.; Jacques, D.B.; Rand, R.; Regis, J.; Peragut, J.C.; Epstein, M.H.; Lindquist, C.

    1995-01-01

    Purpose/Objective: We performed a multi-institution study to evaluate the technique, dose-selection parameters, and results of gamma knife stereotactic radiosurgery in the management of trigeminal neuralgia. We hypothesized that MRI-stereotactic targeting of the trigeminal nerve and irradiation with a single 4 mm isocenter, 2-4 mm anterior to the brainstem, could be a safe and effective treatment for this disorder. Materials and Methods: Fifty patients at five centers had radiosurgery using a single 4 mm isocenter targeted at the root entry zone. All patients had typical trigeminal neuralgia. The mean patient age was 70 years, (range, 40-87). Thirty-two patients had undergone prior surgery, and the mean number of procedures performed was 2.8 (range, 1-7). Eighteen patients (36%) had not had prior surgery before radiosurgery. Maximum radiosurgery doses included 60 Gy (n=8), 65 Gy (n=3), 70 Gy (n=27), 75 Gy (n=2), 80 Gy (n=6) and 90 Gy (n=4). All patients were discharged within 24 hours and were studied in regard to the degree of pain relief, latency interval to pain relief, sensory loss, and the need for further therapy. Mean follow-up after radiosurgery was 9.2 months (range, 2-26 months). Results: At last follow-up, 25 patients (50%) had excellent control (pain-free), 17 (34%) had good control (50-90% relief), and 8 (16%) had failed (see Figure). The median time to pain relief was one month. We identified an actuarial response rate of 53% for complete pain relief at seven months, and 93% for pain reduction (50-100% relief). At 18 months, these results declined to 48% and 77% respectively. A significantly greater proportion of patients receiving a radiosurgery maximum dose of ≥ 70 Gy achieved complete pain relief (63% vs. 18%) and >50% pain reduction (96% vs. 80%) than those with doses <70 Gy. Patients without prior surgery had significantly better outcomes in univariate testing. Three patients (6%) developed increased facial paresthesiae after radiosurgery

  5. Search for fractional charge and heavy stable particles at PETRA

    International Nuclear Information System (INIS)

    Barter, W.; Canzler, T.; Cords, D.; Dittmann, P.; Eichler, R.; Felst, R.; Haidt, D.; Kawabata, S.; Krehbiel, H.; Naroska, B.

    1980-01-01

    A search has been made for new particles with charge Q = 2/3, 1, 4/3, 5/3 produced in e + e - -reactions at PETRA. The energy range was Esub(cm) = 27-35 GeV. No such particles were found. Upper limits for the cross-section depending on the assumed mass and production spectrum are given. For Q = 2/3 quarks with mass less than 12 GeVs 2 , upper limits sigma(q anti q)/sigma(μμ) >= 10 - 2 (90% C.L.) are obtained both for inclusive and exclusive production. For the lifetime of the B-meson (msub(B) = 5 GeV/c 2 ) an upper limit tau - 9 s is obtained. (orig.)

  6. Differences in Clinical Results After LINAC-Based Single-Dose Radiosurgery Versus Fractionated Stereotactic Radiotherapy for Patients With Vestibular Schwannomas

    International Nuclear Information System (INIS)

    Combs, Stephanie E.; Welzel, Thomas; Schulz-Ertner, Daniela; Huber, Peter E.; Debus, Juergen

    2010-01-01

    Purpose: To evaluate the outcomes of patients with vestibular schwannoma (VS) treated with fractionated stereotactic radiotherapy (FSRT) vs. those treated with stereotactic radiosurgery (SRS). Methods and Materials: This study is based on an analysis of 200 patients with 202 VSs treated with FSRT (n = 172) or SRS (n = 30). Patients with tumor progression and/or progression of clinical symptoms were selected for treatment. In 165 out of 202 VSs (82%), RT was performed as the primary treatment for VS, and for 37 VSs (18%), RT was conducted for tumor progression after neurosurgical intervention. For patients receiving FSRT, a median total dose of 57.6 Gy was prescribed, with a median fractionation of 5 x 1.8 Gy per week. For patients who underwent SRS, a median single dose of 13 Gy was prescribed to the 80% isodose. Results: FSRT and SRS were well tolerated. Median follow-up time was 75 months. Local control was not statistically different for both groups. The probability of maintaining the pretreatment hearing level after SRS with doses of ≤13 Gy was comparable to that of FSRT. The radiation dose for the SRS group (≤13 Gy vs. >13 Gy) significantly influenced hearing preservation rates (p = 0.03). In the group of patients treated with SRS doses of ≤13 Gy, cranial nerve toxicity was comparable to that of the FSRT group. Conclusions: FSRT and SRS are both safe and effective alternatives for the treatment of VS. Local control rates are comparable in both groups. SRS with doses of ≤13 Gy is a safe alternative to FSRT. While FSRT can be applied safely for the treatment of VSs of all sizes, SRS should be reserved for smaller lesions.

  7. Maximizing Ion Current by Space Charge Neutralization using Negative Ions and Dust Particles

    International Nuclear Information System (INIS)

    Smirnov, A.; Raitses, Y.; Fisch, N.J.

    2005-01-01

    Ion current extracted from an ion source (ion thruster) can be increased above the Child-Langmuir limit if the ion space charge is neutralized. Similarly, the limiting kinetic energy density of the plasma flow in a Hall thruster might be exceeded if additional mechanisms of space charge neutralization are introduced. Space charge neutralization with high-mass negative ions or negatively charged dust particles seems, in principle, promising for the development of a high current or high energy density source of positive light ions. Several space charge neutralization schemes that employ heavy negatively charged particles are considered. It is shown that the proposed neutralization schemes can lead, at best, only to a moderate but nonetheless possibly important increase of the ion current in the ion thruster and the thrust density in the Hall thruster

  8. Study of the absorbed dose in small fields with absence of lateral electronic balance in stereotactic radiosurgery and radiotherapy with modulated intensity; Estudio de la dosis absorbida en campos pequenos con ausencia de equilibrio electronico lateral en radiocirugia estereotaxica y radioterapia con intensidad modulada

    Energy Technology Data Exchange (ETDEWEB)

    Vargas V, M. X.

    2013-07-01

    In this thesis we develop and experimental and theoretical study, using semi analytical techniques of the physical dosimetry for small and nonstandard fields for stereotactic radiosurgery (Srs) and intensity modulated radiation therapy (IMRT), with high energy photon beams from a BrainLAB system with cones at Instituto del Cancer SOLCA (Ecuador) and a Tomo Therapy Hi-Art system at Centro Oncologico de Chihuahua (Mexico). (Author)

  9. Impact of the track structure of heavy charged particles on cytogenetic damage in human blood lymphocytes

    Science.gov (United States)

    Lee, Ryonfa; Nasonova, Elena; Sommer, Sylwetster; Hartel, Carola; Durante, Marco; Ritter, Sylvia

    In space, astronauts are unavoidably exposed to charged particles from protons to irons. For a better estimate of the health risks of astronauts, further knowledge on the biological effects of charged particles, in particular the induction of cytogenetic damage is required. One im-portant factor that determines the biological response is the track structure of particles, i.e. their microscopic dose deposition in cells. The aim of the present study was to assess the influence of track structure of heavy ions on the yield and the quality of cytogenetic damage in human peripheral blood lymphocytes representing normal tissue. Cells were irradiated with 9.5 MeV/u C-ions or 990 MeV/u Fe-ions which have a comparable LET (175 keV/µm and 155 keV/µm, respectively) but a different track radius (2.3 and 6200 µm, respectively). When aberrations were analyzed in first cycle metaphases collected at different post-irradiation times (48-84 h) following fluorescence plus Giemsa staining, an increase in the aberration yield with sampling time was observed for both radiation qualities reflecting a damage dependent cell cycle progression delay to mitosis. The pronounced differences in the aberration frequency per cell are attributable to the stochastic distribution of particle traversals per cell nucleus (radius: 2.8 µm). Following C-ion exposure we found a high fraction of non-aberrant cells in samples collected at 48 h which represent cells not directly hit by a particle and slightly damaged cells that successfully repaired the induced lesions. In addition, at higher C-ion fluences the aberra-tion yield saturated, suggesting that a fraction of lymphocytes receiving multiple particle hits is not able to reach mitosis. On the other hand, at 48 h after Fe-ion exposure the proportion of non-aberrant cells is lower than after C-ion irradiation clearly reflecting the track structure of high energy particles (i.e. more homogeneous dose deposition compared to low energy C

  10. Tumour response and morphological changes of acoustic neurinomas after radiosurgery

    International Nuclear Information System (INIS)

    Valentino, V.; Raimondi, A.J.

    1995-01-01

    Twenty-seven of the 1560 patients treated by radiosurgery during the period 1984-1993 had acoustic neurinomas. Four cases were excluded from this study because they had a follow-up of less than 2 years. There were 24 neurinomas treated in 23 patients as one patient had a bilateral tumour. Seven patients underwent radiosurgery for a recurrent tumour (already operated on once or twice), while it was the first treatment for 16 patients. The tumour volume ranged from 1.99 cm 3 to 18.30 cm 3 , and the patient follow-up was from 2 to 8 years. To determine the target on CT/NMR for linear accelerator stereotactic irradiation, the Greitz-Bergstroem non-invasive head fixation device was used. It was again adopted for subsequent serial imaging, and for repeat radiosurgery when necessary. The total peripheral tumour dose ranged from 12 to 45 Gy. In 9 patients there was a reduction in tumour volume varying from 39 to 100% , while 14 of the neurinomas appeared stable after an average follow-up of 3 years. In one patient there was an increase in size of the tumour. Variable morphological changes were present in 66% of the neurinomas treated. Radiosurgery is indicated as an alternative to microsurgery for inoperab1e patients and for those who refuse surgery, for recurrent tumours, and as a post-operative complementary treatment for partially removed tumours. A gradual approach to radiosurgery, depending on tumour response, allows a greater efficacy with minimal risk. In the present series no complications were observed. Hearing was preserved at almost the same level as that prior to radiosurgery in all patients. (author)

  11. The 8{pi} miniball charged-particle detector array

    Energy Technology Data Exchange (ETDEWEB)

    Ball, G C; Galindo-Uribarri, A; Andrews, H R; Bray, N C; Lori, J D; Radford, D C; Smith, L V; Tapp, G A; Ward, D [Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.; Drake, T E [Toronto Univ., ON (Canada). Dept. of Physics; Waddington, J C [McMaster Univ., Hamilton, ON (Canada). Dept. of Physics

    1992-08-01

    A modular miniature array of 24 CsI(Tl) crystals (0.5 cm) thick coupled to large area photodiodes has been constructed to operate inside the 8{pi} spectrometer. The array was designed to have good resolution, high efficiency, and adequate granularity for detecting light charged particles emitted in coincidence with the gamma rays from the decay of high-spin states populated in heavy-ion fusion-evaporation reactions. 17 refs., 2 tabs., 3 figs.

  12. Present status and future trends of heavy particle radiotherapy

    International Nuclear Information System (INIS)

    Jones, D.T.L.

    1999-01-01

    Fast neutron therapy began as long ago as 1938 and subsequently proton, alpha particle, heavy ion, pion and neutron capture therapy have been used. To date it is estimated that in excess of 45000 people have undergone some form of particle therapy. In the future it is expected that fast neutron therapy will be used for selected tumour types for which neutrons are known to show improved cure rates. The future trends in charged particle therapy will be driven by increasing commercialization. The future of neutron capture therapy will depend on current clinical trials with epithermal neutron beams and the development of new tumour-seeking drugs. (author)

  13. Calculation of cranial nerve complication probability for acoustic neuroma radiosurgery

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Buatti, John M.; Foote, Kelly D.; Friedman, William A.; Bova, Francis J.

    2000-01-01

    Purpose: Estimations of complications from stereotactic radiosurgery usually rely simply on dose-volume or dose-diameter isoeffect curves. Due to the sparse clinical data available, these curves have typically not considered the target location in the brain, target histology, or treatment plan conformality as parameters in the calculation. In this study, a predictive model was generated to estimate the probability of cranial neuropathies as a result of acoustic schwannoma radiosurgery. Methods and Materials: The dose-volume histogram reduction scheme was used to calculate the normal tissue complication probability (NTCP) from brainstem dose-volume histograms. The model's fitting parameters were optimized to provide the best fit to the observed complication data for acoustic neuroma patients treated with stereotactic radiosurgery at the University of Florida. The calculation was then applied to the remainder of the patients in the database. Results: The best fit to our clinical data was obtained using n = 0.04, m = 0.15, and no. alphano. /no. betano. = 2.1 Gy -1 . Although the fitting parameter m is relatively consistent with ranges found in the literature, both the volume parameter, n, and no. alphano. /no. betano. are much smaller than the values quoted in the literature. The fit to our clinical data indicates that brainstem, or possibly a specific portion of the brainstem, is more radiosensitive than the parameters in the literature indicate, and that there is very little volume effect; in other words, irradiation of a small fraction of the brainstem yields NTCPs that are nearly as high as those calculated for entire volume irradiation. These new fitting parameters are specific to acoustic neuroma radiosurgery, and the small volume effect that we observe may be an artifact of the fixed relationship of acoustic tumors to specific regions of the brainstem. Applying the model to our patient database, we calculate an average NTCP of 7.2% for patients who had no

  14. Acceleration of the charged particles due to chaotic scattering in the combined black hole gravitational field and asymptotically uniform magnetic field

    International Nuclear Information System (INIS)

    Stuchlik, Zdenek; Kolos, Martin

    2016-01-01

    To test the role of large-scale magnetic fields in accretion processes, we study the dynamics of the charged test particles in the vicinity of a black hole immersed into an asymptotically uniform magnetic field. Using the Hamiltonian formalism of the charged particle dynamics, we examine chaotic scattering in the effective potential related to the black hole gravitational field combined with the uniform magnetic field. Energy interchange between the translational and oscillatory modes of the charged particle dynamics provides a mechanism for charged particle acceleration along the magnetic field lines. This energy transmutation is an attribute of the chaotic charged particle dynamics in the combined gravitational and magnetic fields only, the black hole rotation is not necessary for such charged particle acceleration. The chaotic scatter can cause a transition to the motion along the magnetic field lines with small radius of the Larmor motion or vanishing Larmor radius, when the speed of the particle translational motion is largest and it can be ultra-relativistic. We discuss the consequences of the model of ionization of test particles forming a neutral accretion disc, or heavy ions following off-equatorial circular orbits, and we explore the fate of heavy charged test particles after ionization where no kick of heavy ions is assumed and only the switch-on effect of the magnetic field is relevant. We demonstrate that acceleration and escape of the ionized particles can be efficient along the Kerr black hole symmetry axis parallel to the magnetic field lines. We show that a strong acceleration of the ionized particles to ultra-relativistic velocities is preferred in the direction close to the magnetic field lines. Therefore, the process of ionization of Keplerian discs around the Kerr black holes can serve as a model of relativistic jets. (orig.)

  15. Acceleration of the charged particles due to chaotic scattering in the combined black hole gravitational field and asymptotically uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Stuchlik, Zdenek; Kolos, Martin [Silesian University in Opava, Faculty of Philosophy and Science, Institute of Physics and Research Centre of Theoretical Physics and Astrophysics, Opava (Czech Republic)

    2016-01-15

    To test the role of large-scale magnetic fields in accretion processes, we study the dynamics of the charged test particles in the vicinity of a black hole immersed into an asymptotically uniform magnetic field. Using the Hamiltonian formalism of the charged particle dynamics, we examine chaotic scattering in the effective potential related to the black hole gravitational field combined with the uniform magnetic field. Energy interchange between the translational and oscillatory modes of the charged particle dynamics provides a mechanism for charged particle acceleration along the magnetic field lines. This energy transmutation is an attribute of the chaotic charged particle dynamics in the combined gravitational and magnetic fields only, the black hole rotation is not necessary for such charged particle acceleration. The chaotic scatter can cause a transition to the motion along the magnetic field lines with small radius of the Larmor motion or vanishing Larmor radius, when the speed of the particle translational motion is largest and it can be ultra-relativistic. We discuss the consequences of the model of ionization of test particles forming a neutral accretion disc, or heavy ions following off-equatorial circular orbits, and we explore the fate of heavy charged test particles after ionization where no kick of heavy ions is assumed and only the switch-on effect of the magnetic field is relevant. We demonstrate that acceleration and escape of the ionized particles can be efficient along the Kerr black hole symmetry axis parallel to the magnetic field lines. We show that a strong acceleration of the ionized particles to ultra-relativistic velocities is preferred in the direction close to the magnetic field lines. Therefore, the process of ionization of Keplerian discs around the Kerr black holes can serve as a model of relativistic jets. (orig.)

  16. Theoretical aspects of the formation and evolution of charged particle tracks

    CERN Document Server

    Miterev, A M

    2002-01-01

    Theoretical ideas on the formation and evolution of charged particle tracks in a condensed medium are discussed. The historical development of the field is briefly reviewed. The distribution of charged particle energies on quantum states and the volume of the absorbing medium are considered. and conditions for the formation of various track structures are discussed. The structures of extended heavy-ion tracks are compared for some ion parameters and track characteristics take to be the same. Relaxation processes in the tracks of multicharged ions ate analyzed. Track effects ate considered and possible mechanisms for the formation of chemically active defects in a latent track are described

  17. Charge identification of highly ionizing particles in desensitized nuclear emulsion using high speed read-out system

    International Nuclear Information System (INIS)

    Toshito, T.; Kodama, K.; Yusa, K.; Ozaki, M.; Amako, K.; Kameoka, S.; Murakami, K.; Sasaki, T.; Aoki, S.; Ban, T.; Fukuda, T.; Naganawa, N.; Nakamura, T.; Natsume, M.; Niwa, K.; Takahashi, S.; Kanazawa, M.; Kanematsu, N.; Komori, M.; Sato, S.; Asai, M.; Koi, T.; Fukushima, C.; Ogawa, S.; Shibasaki, M.; Shibuya, H.

    2006-01-01

    We performed an experimental study of charge identification of heavy ions from helium to carbon having energy of about 290MeV/u using an emulsion chamber. Emulsion was desensitized by means of forced fading (refreshing) to expand a dynamic range of response to highly charged particles. For the track reconstruction and charge identification, the fully automated high speed emulsion read-out system, which was originally developed for identifying minimum ionizing particles, was used without any modification. Clear track by track charge identification up to Z=6 was demonstrated. The refreshing technique has proved to be a powerful technique to expand response of emulsion film to highly ionizing particles

  18. Particle and heavy ion transport code system; PHITS

    International Nuclear Information System (INIS)

    Niita, Koji

    2004-01-01

    Intermediate and high energy nuclear data are strongly required in design study of many facilities such as accelerator-driven systems, intense pulse spallation neutron sources, and also in medical and space technology. There is, however, few evaluated nuclear data of intermediate and high energy nuclear reactions. Therefore, we have to use some models or systematics for the cross sections, which are essential ingredients of high energy particle and heavy ion transport code to estimate neutron yield, heat deposition and many other quantities of the transport phenomena in materials. We have developed general purpose particle and heavy ion transport Monte Carlo code system, PHITS (Particle and Heavy Ion Transport code System), based on the NMTC/JAM code by the collaboration of Tohoku University, JAERI and RIST. The PHITS has three important ingredients which enable us to calculate (1) high energy nuclear reactions up to 200 GeV, (2) heavy ion collision and its transport in material, (3) low energy neutron transport based on the evaluated nuclear data. In the PHITS, the cross sections of high energy nuclear reactions are obtained by JAM model. JAM (Jet AA Microscopic Transport Model) is a hadronic cascade model, which explicitly treats all established hadronic states including resonances and all hadron-hadron cross sections parametrized based on the resonance model and string model by fitting the available experimental data. The PHITS can describe the transport of heavy ions and their collisions by making use of JQMD and SPAR code. The JQMD (JAERI Quantum Molecular Dynamics) is a simulation code for nucleus nucleus collisions based on the molecular dynamics. The SPAR code is widely used to calculate the stopping powers and ranges for charged particles and heavy ions. The PHITS has included some part of MCNP4C code, by which the transport of low energy neutron, photon and electron based on the evaluated nuclear data can be described. Furthermore, the high energy nuclear

  19. A dental solution to the reproducible frameless stereotactic problem in fractionated radiosurgery

    International Nuclear Information System (INIS)

    Wasserman, Richard M.; Andres, Eric; Sibata, Claudio; Acharya, Raj; Shin, K.H.

    1996-01-01

    Purpose/Objective: Stereotactic radiosurgery forms an important component of many brain tumor protocols. Patient treatment may be improved when doses are delivered in a fractionated manner over a series of days. Current radiosurgical practices prevent such treatments due to the inaccuracy associated with repeatedly registering pre-treatment imaging scans with the patient's physical location over a discrete series of sessions. We propose a new system for pseudo-frameless stereotactic radio-surgery in which the traditional halo frame system is replaced by a series of dental brackets attached to the upper teeth of each patient. Each bracket may then be fit with sets of fiducial markers which can be localized in the imaging and physical spaces. Patient immobilization will be performed via a custom fit face mask. By decoupling head localization and head immobilization tasks, highly accurate and reproducible fractionated treatment plans may be delivered during a series of treatment sessions. Materials and Methods An experimental custom phantom system was developed in order to evaluate the efficacy of our approach. A rigid head phantom which may be displaced with three rotational degrees of freedom was constructed and fitted with prototype dental brackets. A high contrast CT imaging fixture was then attached to each bracket. The true position of the fixed dental brackets was calculated by direct measurement prior to imaging. Angular encoders were employed to measure the rotational degrees of freedom of the phantom. Multiple imaging scans over a series of series of days were obtained at the Roswell Park Cancer Institute. The high contrast imaging fixtures were removed and replaced prior to each scan in order to best simulate clinical conditions. The origin of each bracket was calculated using analysis software developed at our institution. In order to localize the bracket coordinates in physical space, a specialized probe was constructed with a tip that can interlock with

  20. Dosimetry of cone-defined stereotactic radiosurgery fields with a commercial synthetic diamond detector.

    Science.gov (United States)

    Morales, Johnny E; Crowe, Scott B; Hill, Robin; Freeman, Nigel; Trapp, J V

    2014-11-01

    Small field x-ray beam dosimetry is difficult due to lack of lateral electronic equilibrium, source occlusion, high dose gradients, and detector volume averaging. Currently, there is no single definitive detector recommended for small field dosimetry. The objective of this work was to evaluate the performance of a new commercial synthetic diamond detector, namely, the PTW 60019 microDiamond, for the dosimetry of small x-ray fields as used in stereotactic radiosurgery (SRS). Small field sizes were defined by BrainLAB circular cones (4-30 mm diameter) on a Novalis Trilogy linear accelerator and using the 6 MV SRS x-ray beam mode for all measurements. Percentage depth doses (PDDs) were measured and compared to an IBA SFD and a PTW 60012 E diode. Cross profiles were measured and compared to an IBA SFD diode. Field factors, ΩQclin,Qmsr (fclin,fmsr) , were calculated by Monte Carlo methods using BEAMnrc and correction factors, kQclin,Qmsr (fclin,fmsr) , were derived for the PTW 60019 microDiamond detector. For the small fields of 4-30 mm diameter, there were dose differences in the PDDs of up to 1.5% when compared to an IBA SFD and PTW 60012 E diode detector. For the cross profile measurements the penumbra values varied, depending upon the orientation of the detector. The field factors, ΩQclin,Qmsr (fclin,fmsr) , were calculated for these field diameters at a depth of 1.4 cm in water and they were within 2.7% of published values for a similar linear accelerator. The corrections factors, kQclin,Qmsr (fclin,fmsr) , were derived for the PTW 60019 microDiamond detector. The authors conclude that the new PTW 60019 microDiamond detector is generally suitable for relative dosimetry in small 6 MV SRS beams for a Novalis Trilogy linear equipped with circular cones.

  1. Association Between Radiation Necrosis and Tumor Biology After Stereotactic Radiosurgery for Brain Metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Jacob A. [Cleveland Clinic Lerner College of Medicine, Cleveland Clinic, Cleveland, Ohio (United States); Bennett, Elizabeth E. [Department of Neurological Surgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio (United States); Xiao, Roy [Cleveland Clinic Lerner College of Medicine, Cleveland Clinic, Cleveland, Ohio (United States); Kotecha, Rupesh [Department of Radiation Oncology, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Chao, Samuel T. [Cleveland Clinic Lerner College of Medicine, Cleveland Clinic, Cleveland, Ohio (United States); Department of Radiation Oncology, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Rose Ella Burkhardt Brain Tumor and Neuro-Oncology Center, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Vogelbaum, Michael A.; Barnett, Gene H.; Angelov, Lilyana [Cleveland Clinic Lerner College of Medicine, Cleveland Clinic, Cleveland, Ohio (United States); Department of Neurological Surgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio (United States); Rose Ella Burkhardt Brain Tumor and Neuro-Oncology Center, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Murphy, Erin S.; Yu, Jennifer S. [Cleveland Clinic Lerner College of Medicine, Cleveland Clinic, Cleveland, Ohio (United States); Department of Radiation Oncology, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Rose Ella Burkhardt Brain Tumor and Neuro-Oncology Center, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); Ahluwalia, Manmeet S. [Cleveland Clinic Lerner College of Medicine, Cleveland Clinic, Cleveland, Ohio (United States); Rose Ella Burkhardt Brain Tumor and Neuro-Oncology Center, Taussig Cancer Institute, Cleveland Clinic, Cleveland, Ohio (United States); and others

    2016-12-01

    Background: The primary dose-limiting toxicity of stereotactic radiosurgery (SRS) is radiation necrosis (RN), which occurs after approximately 5% to 10% of treatments. This adverse event may worsen neurologic deficits, increase the frequency and cost of imaging, and necessitate prolonged treatment with steroids or antiangiogenic agents. Previous investigations have primarily identified lesion size and dosimetric constraints as risk factors for RN in small populations. We hypothesized that disease histology, receptor status, and mutational status are associated with RN. Methods and Materials: All patients presenting with brain metastasis between 1997 and 2015 who underwent SRS and subsequent radiographic follow-up at a single tertiary-care institution were eligible for inclusion. The primary outcome was the cumulative incidence of radiographic RN. Multivariate competing risks regression was used to identify biological risk factors for RN. Results: 1939 patients (5747 lesions) were eligible for inclusion; 285 patients (15%) experienced radiographic RN after the treatment of 427 (7%) lesions. After SRS, the median time to RN was 7.6 months. After multivariate analysis, graded prognostic assessment, renal pathology, lesion diameter, and the heterogeneity index remained independently predictive of RN in the pooled cohort. In subset analyses of individual pathologies, HER2-amplified status (hazard ratio [HR] 2.05, P=.02), BRAF V600+ mutational status (HR 0.33, P=.04), lung adenocarcinoma histology (HR 1.89, P=.04), and ALK rearrangement (HR 6.36, P<.01) were also associated with RN. Conclusions: In the present investigation constituting the largest series of RN, several novel risk factors were identified, including renal histology, lung adenocarcinoma histology, HER2 amplification, and ALK/BRAF mutational status. These risk factors may be used to guide clinical trial design incorporating biological risk stratification or dose escalation. Future studies determining the

  2. Association Between Radiation Necrosis and Tumor Biology After Stereotactic Radiosurgery for Brain Metastasis

    International Nuclear Information System (INIS)

    Miller, Jacob A.; Bennett, Elizabeth E.; Xiao, Roy; Kotecha, Rupesh; Chao, Samuel T.; Vogelbaum, Michael A.; Barnett, Gene H.; Angelov, Lilyana; Murphy, Erin S.; Yu, Jennifer S.; Ahluwalia, Manmeet S.

    2016-01-01

    Background: The primary dose-limiting toxicity of stereotactic radiosurgery (SRS) is radiation necrosis (RN), which occurs after approximately 5% to 10% of treatments. This adverse event may worsen neurologic deficits, increase the frequency and cost of imaging, and necessitate prolonged treatment with steroids or antiangiogenic agents. Previous investigations have primarily identified lesion size and dosimetric constraints as risk factors for RN in small populations. We hypothesized that disease histology, receptor status, and mutational status are associated with RN. Methods and Materials: All patients presenting with brain metastasis between 1997 and 2015 who underwent SRS and subsequent radiographic follow-up at a single tertiary-care institution were eligible for inclusion. The primary outcome was the cumulative incidence of radiographic RN. Multivariate competing risks regression was used to identify biological risk factors for RN. Results: 1939 patients (5747 lesions) were eligible for inclusion; 285 patients (15%) experienced radiographic RN after the treatment of 427 (7%) lesions. After SRS, the median time to RN was 7.6 months. After multivariate analysis, graded prognostic assessment, renal pathology, lesion diameter, and the heterogeneity index remained independently predictive of RN in the pooled cohort. In subset analyses of individual pathologies, HER2-amplified status (hazard ratio [HR] 2.05, P=.02), BRAF V600+ mutational status (HR 0.33, P=.04), lung adenocarcinoma histology (HR 1.89, P=.04), and ALK rearrangement (HR 6.36, P<.01) were also associated with RN. Conclusions: In the present investigation constituting the largest series of RN, several novel risk factors were identified, including renal histology, lung adenocarcinoma histology, HER2 amplification, and ALK/BRAF mutational status. These risk factors may be used to guide clinical trial design incorporating biological risk stratification or dose escalation. Future studies determining the

  3. Phase II study to assess the efficacy of conventionally fractionated radiotherapy followed by a stereotactic radiosurgery boost in patients with locally advanced pancreatic cancer

    International Nuclear Information System (INIS)

    Koong, Albert C.; Christofferson, Erin; Le, Quynh-Thu; Goodman, Karyn A.; Ho, Anthony; Kuo, Timothy; Ford, James M.; Fisher, George A.; Greco, Ralph; Norton, Jeffrey; Yang, George P.

    2005-01-01

    Purpose: To determine the efficacy of concurrent 5-fluorouracil (5-FU) and intensity-modulated radiotherapy (IMRT) followed by body stereotactic radiosurgery (SRS) in patients with locally advanced pancreatic cancer. Methods and Materials: In this prospective study, all patients (19) had pathologically confirmed adenocarcinoma and were uniformly staged. Our treatment protocol consisted of 45 Gy IMRT with concurrent 5-FU followed by a 25 Gy SRS boost to the primary tumor. Results: Sixteen patients completed the planned therapy. Two patients experienced Grade 3 toxicity (none had more than Grade 3 toxicity). Fifteen of these 16 patients were free from local progression until death. Median overall survival was 33 weeks. Conclusions: Concurrent IMRT and 5-FU followed by SRS in patients with locally advanced pancreatic cancer results in excellent local control, but does not improve overall survival and is associated with more toxicity than SRS, alone

  4. Accuracy of marketing claims by providers of stereotactic radiation therapy.

    Science.gov (United States)

    Narang, Amol K; Lam, Edwin; Makary, Martin A; Deweese, Theodore L; Pawlik, Timothy M; Pronovost, Peter J; Herman, Joseph M

    2013-01-01

    Direct-to-consumer advertising by industry has been criticized for encouraging overuse of unproven therapies, but advertising by health care providers has not been as carefully scrutinized. Stereotactic radiation therapy is an emerging technology that has sparked controversy regarding the marketing campaigns of some manufacturers. Given that this technology is also being heavily advertised on the Web sites of health care providers, the accuracy of providers' marketing claims should be rigorously evaluated. We reviewed the Web sites of all U.S. hospitals and private practices that provide stereotactic radiation using two leading brands of stereotactic radiosurgery technology. Centers were identified by using data from the manufacturers. Centers without Web sites were excluded. The final study population consisted of 212 centers with online advertisements for stereotactic radiation. Web sites were evaluated for advertisements that were inconsistent with advertising guidelines provided by the American Medical Association. Most centers (76%) had individual pages dedicated to the marketing of their brand of stereotactic technology that frequently contained manufacturer-authored images (50%) or text (55%). Advertising for the treatment of tumors that have not been endorsed by professional societies was present on 66% of Web sites. Centers commonly claimed improved survival (22%), disease control (20%), quality of life (17%), and toxicity (43%) with stereotactic radiation. Although 40% of Web sites championed the center's regional expertise in delivering stereotactic treatments, only 15% of Web sites provided data to support their claims. Provider advertisements for stereotactic radiation were prominent and aggressive. Further investigation of provider advertising, its effects on quality of care, and potential oversight mechanisms is needed.

  5. Simple standard model extension by heavy charged scalar

    Science.gov (United States)

    Boos, E.; Volobuev, I.

    2018-05-01

    We consider a Standard Model (SM) extension by a heavy charged scalar gauged only under the UY(1 ) weak hypercharge gauge group. Such an extension, being gauge invariant with respect to the SM gauge group, is a simple special case of the well-known Zee model. Since the interactions of the charged scalar with the Standard Model fermions turn out to be significantly suppressed compared to the Standard Model interactions, the charged scalar provides an example of a long-lived charged particle being interesting to search for at the LHC. We present the pair and single production cross sections of the charged scalar at different colliders and the possible decay widths for various boson masses. It is shown that the current ATLAS and CMS searches at 8 and 13 TeV collision energy lead to the bounds on the scalar boson mass of about 300-320 GeV. The limits are expected to be much larger for higher collision energies and, assuming 15 a b-1 integrated luminosity, reach about 2.7 TeV at future 27 TeV LHC thus covering the most interesting mass region.

  6. Study of Doubly Charged Delta Baryons in Collisions of Copper Nuclei at the Relativistic Heavy Ion Collider

    Science.gov (United States)

    2017-05-22

    connecting the three quarks. Composite particles composed of partons are known as “hadrons” and must have a neutral color charge. There are six... neutral charge of neutrons. The up quark has positive charge equivalent to two-thirds the charge of an electron, and the down quark has negative...known as “heavy ions.” An ion is an atom or molecule with net electric charge, bare nuclei have a large positive charge due to the absence of

  7. Analytical calculation of central-axis dosimetric data for a dedicated 6-MV radiosurgery linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Yang, James N.; Pino, Ramiro [Department of Radiation Physics, Unit 94, University of Texas M. D. Anderson Cancer Center, Houston, Texas 77030 (United States); Department of Radiology, Baylor College of Medicine and Methodist Hospital, Houston, Texas 77030 (United States)

    2008-10-15

    Narrow beams are extensively used in stereotactic radiosurgery. The accuracy of treatment planning dose calculation depends largely on how well the dosimetric data are measured during the machine commissioning. Narrow beams are characterized by the lack of lateral electronic equilibrium. The lateral electronic disequilibrium in the radiation field and detector's finite size are likely to compromise the accuracy in dose measurements in these beams. This may have a profound impact on outcome in patients who undergo stereotactic radiosurgery. To confirm the measured commissioning data for a dedicated 6-MV linear accelerator-based radiosurgery system, we developed an analytical model to calculate the narrow photon beam central-axis dose. This model is an extension of a previously reported method of Nizin and Mooij for the calculation of the absorbed dose under lateral electronic disequilibrium conditions at depth of d{sub max} or greater. The scatter factor and tissue-maximum ratio were calculated for narrow beams using the parametrized model and compared to carefully measured results for the same beams. For narrow beam radii ranging from 0.2 to 1.5 cm, the differences between the analytical and measured scatter factors were no greater than 1.4%. In addition, the differences between the analytical and measured tissue-maximum ratios were within 3.3% for regions greater than the maximum dose depth. The estimated error of this analytical calculation was less than 2%, which is sufficient to validate measurement results.

  8. Energy distribution of projectile fragment particles in heavy ion therapeutic beam

    Energy Technology Data Exchange (ETDEWEB)

    Matsufuji, Naruhiro; Tomura, Hiromi; Futami, Yasuyuki [National Inst. of Radiological Sciences, Chiba (Japan)] [and others

    1998-03-01

    Production of fragment particles in a patient`s body is one of important problems for heavy charged particle therapy. It is required to know the yield and the energy spectrum for each fragment element - so called `beam quality` to understand the effect of therapeutic beam precisely. In this study, fragment particles produced by practical therapeutic beam of HIMAC were investigated with using tissue-equivalent material and a detector complex. From the results, fragment particles were well identified by difference of their atomic numbers and the beam quality was derived. Responses of the detectors in this energy region were also researched. (author)

  9. Stereotactic radiation therapy for large vestibular schwannomas

    International Nuclear Information System (INIS)

    Mandl, Ellen S.; Meijer, Otto W.M.; Slotman, Ben J.; Vandertop, W. Peter; Peerdeman, Saskia M.

    2010-01-01

    Background and purpose: To evaluate the morbidity and tumor-control rate in the treatment of large vestibular schwannomas (VS) after stereotactic radiation therapy in our institution. Material and methods: Twenty-five consecutive patients (17 men, 8 women) with large VS (diameter 3.0 cm or larger), treated with stereotactic radiotherapy (SRT) or stereotactic radiosurgery (SRS) between 1992 and 2007, were retrospectively studied after a mean follow-up period of three years with respect to tumor-control rate and complications. Results: Actuarial 5-year maintenance of pre-treatment hearing level probability of 30% was achieved. Five of 17 patients suffered permanent new facial nerve dysfunction. The actuarial 5-year facial nerve preservation probability was 80%. Permanent new trigeminal nerve neuropathy occurred in two of 15 patients, resulting in an actuarial 5-year trigeminal nerve preservation probability of 85%. Tumor progression occurred in four of 25 (16%) patients. The overall 5-year tumor control probability was 82%. Conclusion: Increased morbidity rates were found in patients with large VS treated with SRT or SRS compared to the published series on regular sized VS and other smaller retrospective studies on large VS.

  10. Radiosurgery for metastatic disease at the craniocervical junction.

    Science.gov (United States)

    Tuchman, Alexander; Yu, Cheng; Chang, Eric L; Kim, Paul E; Rusch, Mairead C; Apuzzo, Michael L J

    2014-12-01

    Metastatic disease of the craniovertebral junction (CVJ) can cause pain, cranial nerve deficits, occipitocervical instability, or brainstem/spinal cord compression if left untreated. Many patients with metastasis in this region have a high burden of systemic disease and short life expectancy, making them poor candidates for aggressive surgical resections and fusion procedures. Traditionally, symptom palliation and local disease control in these patients has been achieved through conventional radiation therapy. Stereotactic radiosurgery (SRS) has the advantage of precisely delivering radiation to a target in fewer fractions. To our knowledge, we report the results of the largest series of patients with CVJ metastasis treated with stereotactic radiosurgery. We performed a retrospective review of 9 consecutive patients with 10 tumors of the CVJ treated with SRS at the Keck Medical Center of the University of Southern California. Two tumors were treated with Gamma Knife, whereas the other 8 received CyberKnife. The median marginal dose was 20 Gy (16-24 Gy) over 1-5 fractions. Point maximal dose to the brainstem or spinal cord ranged between 8 and 18.9 Gy. Median survival was 4 months (1-51 months). Five of six patients presenting with pain had at least partial symptom resolution. No patient went on to require surgical decompression or fusion, and there were no complications directly related to SRS. In well-selected patients, SRS for metastatic lesions of the CVJ has a low risk for complications or treatment failure, while achieving a high rate of palliation of pain symptoms. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Single-Fraction Proton Beam Stereotactic Radiosurgery for Cerebral Arteriovenous Malformations

    Energy Technology Data Exchange (ETDEWEB)

    Hattangadi-Gluth, Jona A. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California (United States); Chapman, Paul H. [Department of Neurosurgery, Massachusetts General Hospital, Boston, Massachusetts (United States); Kim, Daniel; Niemierko, Andrzej; Bussière, Marc R.; Stringham, Alison; Daartz, Juliane [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Ogilvy, Christopher [Department of Neurosurgery, Beth Israel Deaconess Medical Center, Boston, Massachusetts (United States); Loeffler, Jay S. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Shih, Helen A., E-mail: hshih@partners.org [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2014-06-01

    Purpose/Objective(s): To evaluate the obliteration rate and potential adverse effects of single-fraction proton beam stereotactic radiosurgery (PSRS) in patients with cerebral arteriovenous malformations (AVMs). Methods and Materials: From 1991 to 2010, 248 consecutive patients with 254 cerebral AVMs received single-fraction PSRS at our institution. The median AVM nidus volume was 3.5 cc (range, 0.1-28.1 cc), 23% of AVMs were in critical/deep locations (basal ganglia, thalamus, or brainstem), and the most common prescription dose was 15 Gy(relative biological effectiveness [RBE]). Univariable and multivariable analyses were performed to assess factors associated with obliteration and hemorrhage. Results: At a median follow-up time of 35 months (range, 6-198 months), 64.6% of AVMs were obliterated. The median time to total obliteration was 31 months (range, 6-127 months), and the 5-year and 10-year cumulative incidence of total obliteration was 70% and 91%, respectively. On univariable analysis, smaller target volume (hazard ratio [HR] 0.78, 95% confidence interval [CI] 0.86-0.93, P<.0001), smaller treatment volume (HR 0.93, 95% CI 0.90-0.96, P<.0001), higher prescription dose (HR 1.16, 95% CI 1.07-1.26, P=.001), and higher maximum dose (HR 1.14, 95% CI 1.05-1.23, P=.002) were associated with total obliteration. Deep/critical location was also associated with decreased likelihood of obliteration (HR 0.68, 95% CI 0.47-0.98, P=.04). On multivariable analysis, critical location (adjusted HR [AHR] 0.42, 95% CI 0.27-0.65, P<.001) and smaller target volume (AHR 0.81, 95% CI 0.68-0.97, P=.02) remained associated with total obliteration. Posttreatment hemorrhage occurred in 13 cases (5-year cumulative incidence of 7%), all among patients with less than total obliteration, and 3 of these events were fatal. The most common complication was seizure, controlled with medications, both acutely (8%) and in the long term (9.1%). Conclusions: The current series is the largest

  12. The neurosurgeon`s perspective; Le point de vue des neurochirurgiens

    Energy Technology Data Exchange (ETDEWEB)

    Lot, G.; Cophignon, J. [Hopital Lariboisiere, 75 - Paris (France)

    1998-03-01

    Stereotactic radiosurgery, a term introduced by Leksell, was born more than 40 years ago, but has made great strides for the last 15 years. There is no consensus among neuro-surgeons as to the best device (gamma knife, linear accelerator), the treatment doses, and the clinical indications of stereotactic radiosurgery. Therefore, this report is the viewpoint of one neurosurgical team only. In the radiosurgery literature, there is no clear evidence of better results with the gamma-knife or the linear accelerators. With regard to clinical applications, cerebral arteriovenous malformations are the more widely accepted indications of radiosurgery, since a cerebral angiography can confirm the disappearance of the nidus of an arteriovenous malformation treated by stereotactic radiosurgery. Usually, small and deep arteriovenous malformations can be treated by stereotactic radiosurgery only. Nevertheless, the treatment of the other arteriovenous malformations more often require procedures including one or several of the following treatment methods: micro-neurosurgery, interventional neuroradiology, stereotactic radiosurgery. Stereotactic radiosurgery in acoustic schwannomas, skull base meningiomas, especially those involving the cavernous sinus, brain metastases, and pituitary tumors seem attractive. Contrary to arteriovenous malformations, the lack of criteria for cure requires a long follow-up and carefully controlled trials to confirm the efficiency of stereotactic radiosurgery for these tumors. On the other hand, experience of stereotactic radiosurgery for astrocytomas and glioblastomas is limited, and few publications are available. Furthermore, because of the infiltrating growth, a major impact of stereotactic radiosurgery for these tumors is presumably not to be expected. Lastly, a close multidisciplinary approach seems absolutely necessary to define the best indications of stereotactic radiosurgery and to improve its clinical results. (authors)

  13. Stereotactic radiosurgery for spinal metastases: a literature review; Radiocirurgia estereotaxica para metastases de coluna vertebral: revisao de literatura

    Energy Technology Data Exchange (ETDEWEB)

    Joaquim, Andrei Fernandes; Ghizoni, Enrico; Tedeschi, Helder; Pereira, Eduardo Baldon; Giacomini, Leonardo Abdala, E-mail: andjoaquim@yahoo.com [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil)

    2013-04-15

    Objective: The spine is the most common location for bone metastases. Since cure is not possible, local control and relief of symptoms is the basis for treatment, which is grounded on the use of conventional radiotherapy. Recently, spinal radiosurgery has been proposed for the local control of spinal metastases, whether as primary or salvage treatment. Consequently, we carried out a literature review in order to analyze the indications, efficacy, and safety of radiosurgery in the treatment of spinal metastases. Methods: We have reviewed the literature using the PubMed gateway with data from the Medline library on studies related to the use of radiosurgery in treatment of bone metastases in spine. The studies were reviewed by all the authors and classified as to level of evidence, using the criterion defined by Wright. Results: The indications found for radiosurgery were primary control of epidural metastases (evidence level II), myeloma (level III), and metastases known to be poor responders to conventional radiotherapy - melanoma and renal cell carcinoma (level III). Spinal radiosurgery was also proposed for salvage treatment after conventional radiotherapy (level II). There is also some evidence as to the safety and efficacy of radiosurgery in cases of extramedullar and intramedullar intradural metastatic tumors (level III) and after spinal decompression and stabilization surgery. Conclusion: Radiosurgery can be used in primary or salvage treatment of spinal metastases, improving local disease control and patient symptoms. It should also be considered as initial treatment for radioresistant tumors, such as melanoma and renal cell carcinoma. (author)

  14. Drying of heavy water system and works of charging heavy water in Fugen

    International Nuclear Information System (INIS)

    Matsushita, Tadashi; Iijima, Setsuo

    1980-01-01

    The advanced thermal reactor ''Fugen'' is the first heavy water-moderated, boiling light water-cooled nuclear reactor for power generation in Japan. It is a large heavy water reactor having about 130 m 3 of heavy water inventory and about 300 m 3 of helium space as the cover gas of the heavy water system. The heavy water required was purchased from FRG, which had been used for the power output test in the KKN, and the quality was 99.82 mol % mean heavy water concentration. The concentration of heavy water for Fugen used for the nuclear design is 99.70 mol%, and it was investigated how heavy water can be charged without lowering the concentration. The matters of investigation include the method of bringing the heavy water and helium system to perfect dryness after washing and light water test, the method of confirming the sufficient dryness to prevent the deterioration, and the method of charging heavy water safely from its containers. On the basis of the results of investigation, the actual works were started. The works of drying the heavy water and helium system by vacuum drying, the works of sampling heavy water and the result of the degree of deterioration, and the works of charging heavy water and the measures to the heavy water remaing in the containers are described. All the works were completed safely and smoothly. (J.P.N.)

  15. Five-Year Outcomes of High-Dose Single-Fraction Spinal Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Moussazadeh, Nelson; Lis, Eric; Katsoulakis, Evangelia; Kahn, Sweena; Svoboda, Marek; DiStefano, Natalie M.; McLaughlin, Lily; Bilsky, Mark H.; Yamada, Yoshiya; Laufer, Ilya

    2015-01-01

    Purpose: To characterize local tumor control and toxicity risk in very long-term survivors (>5 years) after high-dose spinal image guided, intensity modulated radiation therapy delivered as single-dose stereotactic radiosurgery (SRS). Previously published spinal SRS outcome analyses have included a heterogeneous population of cancer patients, mostly with short survival. This is the first study reporting the long-term tumor control and toxicity profiles after high-dose single-fraction spinal SRS. Methods and Materials: The study population included all patients treated from June 2004 to July 2009 with single-fraction spinal SRS (dose 24 Gy) who had survived at least 5 years after treatment. The endpoints examined included disease progression, surgical or radiation retreatment, in-field fracture development, and radiation-associated toxicity, scored using the Radiation Therapy Oncology Group radiation morbidity scoring criteria and the Common Terminology Criteria for Adverse Events, version 4.0. Local control and fracture development were assessed using Kaplan-Meier analysis. Results: Of 278 patients, 31 (11.1%), with 36 segments treated for spinal tumors, survived at least 5 years after treatment and were followed up radiographically and clinically for a median of 6.1 years (maximum 102 months). The histopathologic findings for the 5-year survivors included radiation-resistant metastases in 58%, radiation-sensitive metastases in 22%, and primary bone tumors in 19%. In this selected cohort, 3 treatment failures occurred at a median of 48.6 months, including 2 recurrences in the radiation field and 1 patient with demonstrated progression at the treatment margins. Ten lesions (27.8%) were associated with acute grade 1 cutaneous or gastrointestinal toxicity. Delayed toxicity ≥3 months after treatment included 8 cases (22.2%) of mild neuropathy, 2 (5.6%) of gastrointestinal discomfort, 8 (22.2%) of dermatitides, and 3 (8.3%) of myalgias/myositis. Thirteen

  16. Five-Year Outcomes of High-Dose Single-Fraction Spinal Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Moussazadeh, Nelson [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Lis, Eric [Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Katsoulakis, Evangelia [Department of Radiation Oncology, New York Methodist Hospital, Brooklyn, New York (United States); Kahn, Sweena; Svoboda, Marek; DiStefano, Natalie M.; McLaughlin, Lily [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Bilsky, Mark H. [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States); Yamada, Yoshiya [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Laufer, Ilya, E-mail: lauferi@mskcc.org [Division of Neurological Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Department of Neurological Surgery, Weill Cornell Medical College, New York Presbyterian Hospital, New York, New York (United States)

    2015-10-01

    Purpose: To characterize local tumor control and toxicity risk in very long-term survivors (>5 years) after high-dose spinal image guided, intensity modulated radiation therapy delivered as single-dose stereotactic radiosurgery (SRS). Previously published spinal SRS outcome analyses have included a heterogeneous population of cancer patients, mostly with short survival. This is the first study reporting the long-term tumor control and toxicity profiles after high-dose single-fraction spinal SRS. Methods and Materials: The study population included all patients treated from June 2004 to July 2009 with single-fraction spinal SRS (dose 24 Gy) who had survived at least 5 years after treatment. The endpoints examined included disease progression, surgical or radiation retreatment, in-field fracture development, and radiation-associated toxicity, scored using the Radiation Therapy Oncology Group radiation morbidity scoring criteria and the Common Terminology Criteria for Adverse Events, version 4.0. Local control and fracture development were assessed using Kaplan-Meier analysis. Results: Of 278 patients, 31 (11.1%), with 36 segments treated for spinal tumors, survived at least 5 years after treatment and were followed up radiographically and clinically for a median of 6.1 years (maximum 102 months). The histopathologic findings for the 5-year survivors included radiation-resistant metastases in 58%, radiation-sensitive metastases in 22%, and primary bone tumors in 19%. In this selected cohort, 3 treatment failures occurred at a median of 48.6 months, including 2 recurrences in the radiation field and 1 patient with demonstrated progression at the treatment margins. Ten lesions (27.8%) were associated with acute grade 1 cutaneous or gastrointestinal toxicity. Delayed toxicity ≥3 months after treatment included 8 cases (22.2%) of mild neuropathy, 2 (5.6%) of gastrointestinal discomfort, 8 (22.2%) of dermatitides, and 3 (8.3%) of myalgias/myositis. Thirteen

  17. Semi-automatic determination of the optimum irradiation parameters in stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Boutry, C.; Manens, J.P.; Croci, S.; Scarabin, J.M.

    1995-01-01

    For stereotactic radiosurgery of large lesions or of lesions with irregular shape, the only technique that generates favourable dose distribution is multi-isocentric. The problem is to determine the position of the isocenters that minimize dose heterogeneity within the target volume and maximize the dose gradient outside the target volume. This study was made for two photons energies: γ-rays of Cobalt-60 and 25 MV X-rays. A lead collimator generates circular irradiation beams of diameters 7 to 30 mm at the machine isocenter. By hypothesis, we considered for each isocenter a spherical dose distribution based on an irradiation space defined by sagittal and coronal angular openings of 140 deg. each for 8 equally spaced arcs. The irradiation parameters to be determined are then: the collimator diameter, the number and position of the planes on which the isocenters are placed, and the number and position of the isocenters. We also supposed equidistant isocenters in a linear, triangular, square or complex geometry. The minimum dose point, corresponding to the intersection of the bissectors of the segments joining two consecutive isocenters is inside the geometry. A methodology and rules to determine the irradiation parameters leading to a dose distribution with a reference isodose perfectly adapted to the outlines of the target volume were defined. The collimator diameter is simply correlated to the thickness and the height of the volume to be treated. To determine the number and position of the isocenters we have established simple graphs. These graphs are function of the collimator diameter and the geometric criteria of the volume to be treated (length, thickness, and height). To obtain a dose gradient outside the target volume superior or equal to 5% dose/mm, the collimator diameters must be smaller than or equal to 19 mm for the Cobalt-60 γ-rays and 17 mm for the 25 MV X-rays. For a collimator diameter smaller than or equal to these values, and whatever the photon

  18. Utility and limitation of radiosurgery for metastatic brain tumors

    International Nuclear Information System (INIS)

    Kagawa, Kota; Kiya, Katsuzo; Satoh, Hideki; Mizoue, Tatsuya; Matsushige, Toshinori; Araki, Hayato; Akimitsu, Tomohide

    2003-01-01

    The purpose of this study was to evaluate the utility and limitations of radiosurgery for metastatic brain lesions, and to compare the clinical results of stereotactic radiosurgery (SRS) with those of whole-brain radiation therapy (WBRT) in 45 patients with metastatic brain tumors. The patients were divided into two groups: the SRS group (22 patients) and the WBRT group (23 patients). Mean survival was not significantly different between the two groups. However, in patients with 6 or more lesions, both survival time and recurrence-free time in the SRS group were inferior to those in the WBRT group. The main complication in the SRS group was perifocal edema, while dementia was seen in the WBRT group. The bedridden period was longer in the WBRT group than in the SRS group. Death caused by brain lesions was rare in both groups. From these results, SRS preserves high quality of life longer than WBRT, but SRS should be cautiously used in patients with 6 or more lesions. (author)

  19. Dosimetry of Gamma Knife and linac-based radiosurgery using radiochromic and diode detectors

    International Nuclear Information System (INIS)

    Somigliana, A.; Borelli, S.; Zonca, G.; Pignoli, E.; Loi, G.; Marchesini, R.; Cattaneo, G.M.; Fiorino, C.; Vecchio, A. del; Calandrino, R.

    1999-01-01

    In stereotactic radiosurgery the choice of appropriate detectors, whether for absolute or relative dosimetry, is very important due to the steep dose gradient and the incomplete lateral electronic equilibrium. For both linac-based and Leksell Gamma Knife radiosurgery units, we tested the use of calibrated radiochromic film to measure absolute doses and relative dose distributions. In addition a small diode was used to estimate the relative output factors. The data obtained using radiochromic and diode detectors were compared with measurements performed with other conventional methods of dosimetry, with calculated values by treatment planning systems and with data prestored in the treatment planning system supplied by the Leksell Gamma Knife (LGK) vendor. Two stereotactic radiosurgery techniques were considered: Leksell Gamma Knife (using γ-rays from 60 Co) and linac-based radiosurgery (LR) (6 MV x-rays). Different detectors were used for both relative and absolute dosimetry: relative output factors (OFs) were estimated by using radiochromic and radiographic films and a small diode; relative dose distributions in the axial and coronal planes of a spherical polystyrene phantom were measured using radiochromic film and calculated by two different treatment planning systems (TPSs). The absolute dose at the sphere centre was measured by radiochromic film and a small ionization chamber. An accurate selection of radiochromic film was made: samples of unexposed film showing a percentage standard deviation of less than 3% were used for relative dose profiles, and for absolute dose and OF evaluations this value was reduced to 1.5%. Moreover a proper calibration curve was made for each set of measurements. With regard to absolute doses, the results obtained with the ionization chamber are in good correlation with radiochromic film-generated data, for both LGK and LR, showing a dose difference of less than 1%. The output factor evaluations, performed using different methods

  20. Is medical linac suitable for high-precision stereotactic irradiation? Investigations in geometrical accuracies of gantry and couch

    International Nuclear Information System (INIS)

    Kunieda, Etsuo; Kitamura, Masayuki; Kawaguchi, Osamu; Shigematsu, Naoyuki; Ando, Yutaka; Kubo, Atsushi; Ohira, Takayuki; Tonai, Takenori; Kawase, Takeshi.

    1998-01-01

    Linac-based radiosurgery has many advantages over the gamma knife, including low initial cost and no need of source replacement. On the other hand, most of the medical linacs currently in use were not originally designed to be applied for radiosurgery, and, therefore, careful quality assurance programs are required. In the gantry-head of a linac, a small CCD video camera is mounted in a position optically identical to that of the x-ray source. The video signal from the camera was digitalized to be evaluated for geometrical errors. A metal ball fixed to the stereotactic base frame via XYZ-sliding rods was used as a simulated target. Displacements of the target from the isocenter were measured during rotation of the gantry. Displacements in the gantry-rotation plane were satisfactorily small, while those perpendicular to it were maximal at gantry position angles of 0deg and 180deg. This error might be caused by gravitational vending of the heavy gantry head. Although other major errors of the linac were within one millimeter, the center of coach rotation around the isocenter did not coincide with the center of gantry rotation, probably owing to gravitational vending. Special care should be taken when very small collimators are employed. (author)

  1. A multi-national report on methods for institutional credentialing for spine radiosurgery

    International Nuclear Information System (INIS)

    Gerszten, Peter C; Shin, John H; Winey, Brian; Oh, Kevin; Sweeney, Reinhart A; Guckenberger, Matthias; Sahgal, Arjun; Sheehan, Jason P; Kersh, Ronald; Chen, Stephanie; Flickinger, John C; Quader, Mubina; Fahim, Daniel; Grills, Inga

    2013-01-01

    Stereotactic body radiotherapy and radiosurgery are rapidly emerging treatment options for both malignant and benign spine tumors. Proper institutional credentialing by physicians and medical physicists as well as other personnel is important for the safe and effective adoption of spine radiosurgery. This article describes the methods for institutional credentialing for spine radiosurgery at seven highly experienced international institutions. All institutions (n = 7) are members of the Elekta Spine Radiosurgery Research Consortium and have a dedicated research and clinical focus on image-guided spine radiosurgery. A questionnaire consisting of 24 items covering various aspects of institutional credentialing for spine radiosurgery was completed by all seven institutions. Close agreement was observed in most aspects of spine radiosurgery credentialing at each institution. A formal credentialing process was believed to be important for the implementation of a new spine radiosurgery program, for patient safety and clinical outcomes. One institution has a written policy specific for spine radiosurgery credentialing, but all have an undocumented credentialing system in place. All institutions rely upon an in-house proctoring system for the training of both physicians and medical physicists. Four institutions require physicians and medical physicists to attend corporate sponsored training. Two of these 4 institutions also require attendance at a non-corporate sponsored academic society radiosurgery course. Corporate as well as non-corporate sponsored training were believed to be complimentary and both important for training. In 5 centers, all cases must be reviewed at a multidisciplinary conference prior to radiosurgery treatment. At 3 centers, neurosurgeons are not required to be involved in all cases if there is no evidence for instability or spinal cord compression. Backup physicians and physicists are required at only 1 institution, but all institutions have more

  2. SU-E-T-128: Applying Failure Modes and Effects Analysis to a Risk-Based Quality Management for Stereotactic Radiosurgery in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, F [comissao nacional de energia nuclear, Rio De Janeiro, RJ (Brazil); Universidade do Estado do Rio de Janeiro, Rio De Janeiro, RJ (Brazil); Almeida, C de [Universidade do Estado do Rio de Janeiro, Rio De Janeiro, RJ (Brazil); Huq, M [University of Pittsburgh Medical Center, Pittsburgh, PA (United States)

    2015-06-15

    Purpose: The goal of the present work was to evaluate the process maps for stereotactic radiosurgery (SRS) treatment at three radiotherapy centers in Brazil and apply the FMEA technique to evaluate similarities and differences, if any, of the hazards and risks associated with these processes. Methods: A team, consisting of professionals from different disciplines and involved in the SRS treatment, was formed at each center. Each team was responsible for the development of the process map, and performance of FMEA and FTA. A facilitator knowledgeable in these techniques led the work at each center. The TG100 recommended scales were used for the evaluation of hazard and severity for each step for the major process “treatment planning”. Results: Hazard index given by the Risk Priority Number (RPN) is found to range from 4–270 for various processes and the severity (S) index is found to range from 1–10. The RPN values > 100 and severity value ≥ 7 were chosen to flag safety improvement interventions. Number of steps with RPN ≥100 were found to be 6, 59 and 45 for the three centers. The corresponding values for S ≥ 7 are 24, 21 and 25 respectively. The range of RPN and S values for each center belong to different process steps and failure modes. Conclusion: These results show that interventions to improve safety is different for each center and it is associated with the skill level of the professional team as well as the technology used to provide radiosurgery treatment. The present study will very likely be a model for implementation of risk-based prospective quality management program for SRS treatment in Brazil where currently there are 28 radiotherapy centers performing SRS. A complete FMEA for SRS for these three radiotherapy centers is currently under development.

  3. SU-E-T-128: Applying Failure Modes and Effects Analysis to a Risk-Based Quality Management for Stereotactic Radiosurgery in Brazil

    International Nuclear Information System (INIS)

    Teixeira, F; Almeida, C de; Huq, M

    2015-01-01

    Purpose: The goal of the present work was to evaluate the process maps for stereotactic radiosurgery (SRS) treatment at three radiotherapy centers in Brazil and apply the FMEA technique to evaluate similarities and differences, if any, of the hazards and risks associated with these processes. Methods: A team, consisting of professionals from different disciplines and involved in the SRS treatment, was formed at each center. Each team was responsible for the development of the process map, and performance of FMEA and FTA. A facilitator knowledgeable in these techniques led the work at each center. The TG100 recommended scales were used for the evaluation of hazard and severity for each step for the major process “treatment planning”. Results: Hazard index given by the Risk Priority Number (RPN) is found to range from 4–270 for various processes and the severity (S) index is found to range from 1–10. The RPN values > 100 and severity value ≥ 7 were chosen to flag safety improvement interventions. Number of steps with RPN ≥100 were found to be 6, 59 and 45 for the three centers. The corresponding values for S ≥ 7 are 24, 21 and 25 respectively. The range of RPN and S values for each center belong to different process steps and failure modes. Conclusion: These results show that interventions to improve safety is different for each center and it is associated with the skill level of the professional team as well as the technology used to provide radiosurgery treatment. The present study will very likely be a model for implementation of risk-based prospective quality management program for SRS treatment in Brazil where currently there are 28 radiotherapy centers performing SRS. A complete FMEA for SRS for these three radiotherapy centers is currently under development

  4. Cyst formation after radiosurgery for brain arteriovenous malformation treated with cystoperitoneal shunt

    International Nuclear Information System (INIS)

    Morihiro, Yusuke; Kato, Syoichi; Imoto, Hirochika

    2010-01-01

    Gamma knife and CyberKnife radiosurgery are well established and less invasive treatments for arteriovenous malformation. Delayed cyst formation is a rare but well-known complication of radiosurgery for arteriovenous malformations. The optimal treatment of cysts forming after radiosurgery remains debatable. We present a case of cyst formation after radiosurgery for brain arteriovenous malformation that was treated with a cystoperitoneal shunt (C-P shunt). A 36-year-old woman presented with left hemiparesis and numbness. Computed tomography (CT) revealed intracranial hemorrhage in the right basal ganglia. Digital subtraction angiography revealed arteriovenous malformation in the brain. Intravascular embolization was performed three times and radiosurgery was performed twice, whereby complete obliteration of the nidus was achieved. Six and a half years later, routine follow-up magnetic resonance imaging revealed cyst formation, and the patient gradually developed left hemiparesis. First, we performed stereotactic cyst aspiration. This initially resulted in a reduction in the size of the cyst and disappearance of left hemiparesis, but within a short time, the cyst increased in size again and there was recurrence of hemiparesis. Therefore, an Ommaya reservoir was established; aspiration of the cyst through this reservoir brought about an initial reduction in cyst size and alleviation of symptoms; however, no further reduction in cyst size or improvement in symptoms could be achieved. Twenty months after the placement of the Ommaya reservoir, we performed a C-P shunt operation. After the operation, further reduction in the cyst size and complete symptomatic recovery were observed. (author)

  5. Tumor radiobiology studies with heavy charged-particle beams

    International Nuclear Information System (INIS)

    Curtis, S.B.; Tenforde, T.S.; Tenforde, S.D.; Parr, S.S.; Flynn, M.J.

    1981-01-01

    The response of tumor-cell systems to irradiation with carbon, neon, and argon beams at various positions in the plateau and extended peak regions of the Bragg ionization (dose versus depth) curve is being evaluated from experiments conducted both in vivo and in vitro. The radiobiological end points being studied include: tumor volume response, cellular survival after tumor irradiation in situ, cell-kinetic parameters measured by flow cytofluorometry and time-lapse cinematography, and survival of oxic and hypoxic cells irradiated in suspension. One focus of the research effort during the past year has been on the combined effect of radiosensitizing drugs and charged-particle irradiation. In this article, the results are presented of studies on combined drug and radiation treatment of a rat rhabdomyosarcoma tumor and a human melanoma tumor growing in athymic (thymus-less) nude mice

  6. Evaluation of radiosurgery techniques–Cone-based linac radiosurgery vs tomotherapy-based radiosurgery

    International Nuclear Information System (INIS)

    Yip, Ho Yin; Mui, Wing Lun A.; Lee, Joseph W.Y.; Fung, Winky Wing Ki; Chan, Jocelyn M.T.; Chiu, G.; Law, Maria Y.Y.

    2013-01-01

    Performances of radiosurgery of intracranial lesions between cone-based Linac system and Tomotherapy-based system were compared in terms of dosimetry and time. Twelve patients with single intracranial lesion treated with cone-based Linac radiosurgery system from 2005 to 2009 were replanned for Tomotherapy-based radiosurgery treatment. The conformity index, homogeneity index (HI), and gradient score index (GSI) of each case was calculated. The Wilcoxon matched-pair test was used to compare the 3 indices between both systems. The cases with regular target (n = 6) and those with irregular target (n = 6) were further analyzed separately. The estimated treatment time between both systems was also compared. Significant differences were found in HI (p = 0.05) and in GSI (p = 0.03) for the whole group. Cone-based radiosurgery was better in GSI whereas Tomotherapy-based radiosurgery was better in HI. Cone-based radiosurgery was better in conformity index (p = 0.03) and GSI (p = 0.03) for regular targets, whereas Tomotherapy-based radiosurgery system performed significantly better in HI (p = 0.03) for irregular targets. The estimated total treatment time for Tomotherapy-based radiosurgery ranged from 24 minutes to 35 minutes, including 15 minutes of pretreatment megavoltage computed tomography (MVCT) and image registration, whereas that for cone-based radiosurgery ranged from 15 minutes for 1 isocenter to 75 minutes for 5 isocenters. As a rule of thumb, Tomotherapy-based radiosurgery system should be the first-line treatment for irregular lesions because of better dose homogeneity and shorter treatment time. Cone-based Linac radiosurgery system should be the treatment of choice for regular targets because of the better dose conformity, rapid dose fall-off, and reasonable treatment time

  7. Evaluation of radiosurgery techniques–Cone-based linac radiosurgery vs tomotherapy-based radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Yip, Ho Yin, E-mail: hoyinyip@yahoo.com.hk [Department of Radiotherapy, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong (China); Mui, Wing Lun A.; Lee, Joseph W.Y.; Fung, Winky Wing Ki; Chan, Jocelyn M.T.; Chiu, G. [Department of Radiotherapy, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong (China); Law, Maria Y.Y. [Medical Physics and Research Department, Hong Kong Sanatorium and Hospital, Happy Valley, Hong Kong (China)

    2013-07-01

    Performances of radiosurgery of intracranial lesions between cone-based Linac system and Tomotherapy-based system were compared in terms of dosimetry and time. Twelve patients with single intracranial lesion treated with cone-based Linac radiosurgery system from 2005 to 2009 were replanned for Tomotherapy-based radiosurgery treatment. The conformity index, homogeneity index (HI), and gradient score index (GSI) of each case was calculated. The Wilcoxon matched-pair test was used to compare the 3 indices between both systems. The cases with regular target (n = 6) and those with irregular target (n = 6) were further analyzed separately. The estimated treatment time between both systems was also compared. Significant differences were found in HI (p = 0.05) and in GSI (p = 0.03) for the whole group. Cone-based radiosurgery was better in GSI whereas Tomotherapy-based radiosurgery was better in HI. Cone-based radiosurgery was better in conformity index (p = 0.03) and GSI (p = 0.03) for regular targets, whereas Tomotherapy-based radiosurgery system performed significantly better in HI (p = 0.03) for irregular targets. The estimated total treatment time for Tomotherapy-based radiosurgery ranged from 24 minutes to 35 minutes, including 15 minutes of pretreatment megavoltage computed tomography (MVCT) and image registration, whereas that for cone-based radiosurgery ranged from 15 minutes for 1 isocenter to 75 minutes for 5 isocenters. As a rule of thumb, Tomotherapy-based radiosurgery system should be the first-line treatment for irregular lesions because of better dose homogeneity and shorter treatment time. Cone-based Linac radiosurgery system should be the treatment of choice for regular targets because of the better dose conformity, rapid dose fall-off, and reasonable treatment time.

  8. Measurement of charge and energy spectra of heavy nuclei aboard Cosmos-936 artificial Earth satellite

    International Nuclear Information System (INIS)

    Dashin, S.A.; Marennyy, A.M.; Gertsen, G.P.

    1982-07-01

    Charge and energy spectra of heavy charged particles were measured. Measurements were performed by a package of dielectric track detectors mounted behind the shield of 60-80 kg m to the minus second power thick. The charge of nuclei was determined from the complete track length. A group of 1915 tracks of nuclei with Z 6 in the energy range 100-450 MeV/nuclon were identified. The differential charge spectrum of nuclei with 6 Z 28 and the energy spectrum of nuclei of the iron group were built

  9. A Charged Particle Veto Wall for the Large Area Neutron Array (LANA)

    Science.gov (United States)

    Zhu, K.; Chajecki, Z.; Anderson, C.; Bromell, J.; Brown, K.; Crosby, J.; Kodali, S.; Lynch, W. G.; Morfouace, P.; Sweany, S.; Tsang, M. B.; Tsang, C.; Brett, J. J.; Swaim, J. L.

    2017-09-01

    Comparison of neutrons and protons emitted in heavy ion collisions is one of the observables to probe symmetry energy, which is related to the properties of neutron star. In general, neutrons are difficult to measure and neutron detectors are not as easy to use or as widely available as charged particle detectors. Two neutron walls (NW) called LANA exist at the National Superconducting Cyclotron Laboratory. Although the NSCL NW attains excellent discrimination of γ rays and neutron, it fails to discriminate charged particles from neutrons. To ensure near 100% rejection of charged particles, a Charged Particle Veto Wall (VW) is being jointly built by Michigan State University and Western Michigan University. It will be placed in front of one NW. To increase efficiency in detecting neutrons, the second neutron wall is stacked behind it. In this presentation, I will discuss the design, construction and testing of the VW together with the LANA in preparation of two approved NSCL experiments to probe the density and momentum dependence of the symmetry energy potentials in the equation state of the asymmetric nuclear matter. This material is based upon work supported by the National Science Foundation under Grant No. PHY 1565546.

  10. When is a heavy quark not a parton? Charged Higgs production and heavy quark mass effects in the QCD-based parton model

    International Nuclear Information System (INIS)

    Olness, F.I.; Tung, Wu-Ki

    1989-10-01

    Applications of the QCD-based parton model to new physics processes involving heavy partons are illustrated using charged Higgs production. The naive parton model predictions are found to over-estimate the actual cross section by a factor of 2 to 5. The role of the top quark as a ''parton'' is examined, and the energy range over which heavy quarks (or other particles) should or should not be naturally treated as ''partons'' is delineated. 12 refs., 5 figs

  11. Charge collection efficiency of GaAs detectors studied with low-energy heavy charged particles

    CERN Document Server

    Bates, R; Linhart, V; O'Shea, V; Pospísil, S; Raine, C; Smith, K; Sinor, M; Wilhelm, I

    1999-01-01

    Epitaxially grown GaAs layers have recently been produced with sufficient thickness and low enough free carrier concentration to permit their use as radiation detectors. Initial tests have shown that the epi-material behaves as a classical semiconductor as the depletion behaviour follows the square root dependency on the applied bias. This article presents the results of measurements of the growth of the active depletion depth with increasing bias using low-energy protons and alpha particles as probes for various depths and their comparison to values extrapolated from capacitance measurements. From the proton and alpha particle spectroscopic measurements, an active depth of detector material that collects 100% of the charge generated inside it was determined. The consistency of these results with independent capacitance measurements supports the idea that the GaAs epi-material behaves as a classical semiconductor. (author)

  12. Risk factors for neurological complications after acoustic neurinoma radiosurgery: refinement from further experiences

    International Nuclear Information System (INIS)

    Ito, Ken; Shin, Masahiro; Matsuzaki, Masaki; Sugasawa, Keiko; Sasaki, Tomio

    2000-01-01

    Purpose: Further actuarial analyses of neurological complications were performed on a larger population treated by stereotactic radiosurgery at our institution, to establish the optimal treatment parameters. Methods and Materials: Between June 1990 and September 1998, 138 patients with acoustic neurinomas underwent stereotactic radiosurgery at Tokyo University Hospital. Of these, 125 patients who received medical follow-up for 6 months or more entered the present study. Patient ages ranged from 13 to 77 years (median, 53 years). Average tumor diameter ranged from 6.7 to 25.4 mm (mean, 13.9 mm). Maximum tumor doses ranged from 20 to 40 Gy (mean, 29.8 Gy) and peripheral doses from 12 to 25 Gy (mean, 15.4 Gy). One to 12 isocenters were used (median, 4). Follow-up period ranged from 6 to 104 months (median, 37 months). The potential risk factors for neurological complications were analyzed by two univariate and one multivariate actuarial analyses. Neurological complications examined include hearing loss, facial palsy, and trigeminal nerve dysfunction. Variables included in the analyses were four demographic variables, two variables concerning tumor dimensions, and four variables concerning treatment parameters. A variable with significant p values (p < 0.05) on all three actuarial analyses was considered a risk factor. Results: The variables that had significant correlation to increasing the risk for each neurological complication were: Neurofibromatosis Type 2 (NF2) for both total hearing loss and pure tone threshold (PTA) elevation; history of prior surgical resection, tumor size, and the peripheral tumor dose for facial palsy; and the peripheral tumor dose and gender (being female) for trigeminal neuropathy. In facial palsies caused by radiosurgery, discrepancy between the course of palsy and electrophysiological responses was noted. Conclusion: Risk factors for neurological complications seem to have been almost established, without large differences between

  13. Heavy particle radiotherapy: prospects and pitfalls

    International Nuclear Information System (INIS)

    Faju, M.R.

    1980-01-01

    The use of heavy particles in radiotherapy of tumor volumes is examined. Particles considered are protons, helium ions, heavy ions, negative pions, and fast neutrons. Advantages and disadvantages are discussed

  14. Fluorescent nuclear track images of Ag-activated phosphate glass irradiated with photons and heavy charged particles

    Energy Technology Data Exchange (ETDEWEB)

    Kurobori, Toshio, E-mail: kurobori@staff.kanazawa-u.ac.jp [Graduate School of Natural Science and Technology, Kanazawa University, Kakuma, Kanazawa 920-1192 (Japan); Yanagida, Yuka [Oarai Research Center, Chiyoda Technol Corporation, Oarai-machi, Ibaraki 311-1313 (Japan); Kodaira, Satoshi [National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Shirao, Taichi [Nikon Instech Co., Ltd., Tanakanishi, Sakyo-ku, Kyoto 606-8221 (Japan)

    2017-05-21

    In this paper we report about the demonstration of the nuclear track imaging capabilities of Ag-activated phosphate glass. A 375 nm laser and confocal laser scanning microscopy (CLSM) were respectively used for track excitation and detection. Specifically, the blue and orange radiophotoluminescent (RPL) tracks and dose distributions observed after irradiation with soft X-rays, gamma rays and heavy charged particles (HCPs) are examined. In addition, the origins of the reductions in RPL efficiency for high-dose X-ray irradiation and for irradiation with HCPs with high linear energy transfer (LET) values are investigated via a CLSM and a conventional fluorescent reader and discussed. - Highlights: • 3D track images are demonstrated using a confocal laser microscopy. • Fluorescent track detectors are based on RPL Ag-doped phosphate glass. • The dose distributions are examined for X-ray, gamma ray and HCP irradiations. • The origins of the reduction in RPL efficiency are investigated and discussed.

  15. Fluorescent nuclear track images of Ag-activated phosphate glass irradiated with photons and heavy charged particles

    International Nuclear Information System (INIS)

    Kurobori, Toshio; Yanagida, Yuka; Kodaira, Satoshi; Shirao, Taichi

    2017-01-01

    In this paper we report about the demonstration of the nuclear track imaging capabilities of Ag-activated phosphate glass. A 375 nm laser and confocal laser scanning microscopy (CLSM) were respectively used for track excitation and detection. Specifically, the blue and orange radiophotoluminescent (RPL) tracks and dose distributions observed after irradiation with soft X-rays, gamma rays and heavy charged particles (HCPs) are examined. In addition, the origins of the reductions in RPL efficiency for high-dose X-ray irradiation and for irradiation with HCPs with high linear energy transfer (LET) values are investigated via a CLSM and a conventional fluorescent reader and discussed. - Highlights: • 3D track images are demonstrated using a confocal laser microscopy. • Fluorescent track detectors are based on RPL Ag-doped phosphate glass. • The dose distributions are examined for X-ray, gamma ray and HCP irradiations. • The origins of the reduction in RPL efficiency are investigated and discussed.

  16. Centrality and energy dependence of charged-particle multiplicities in heavy ion collisions in the context of elementary reactions

    Science.gov (United States)

    Back, B. B.; Baker, M. D.; Barton, D. S.; Betts, R. R.; Ballintijn, M.; Bickley, A. A.; Bindel, R.; Budzanowski, A.; Busza, W.; Carroll, A.; Decowski, M. P.; García, E.; George, N.; Gulbrandsen, K.; Gushue, S.; Halliwell, C.; Hamblen, J.; Heintzelman, G. A.; Henderson, C.; Hofman, D. J.; Hollis, R. S.; Hołyński, R.; Holzman, B.; Iordanova, A.; Johnson, E.; Kane, J. L.; Katzy, J.; Khan, N.; Kucewicz, W.; Kulinich, P.; Kuo, C. M.; Lin, W. T.; Manly, S.; McLeod, D.; Michałowski, J.; Mignerey, A. C.; Nouicer, R.; Olszewski, A.; Pak, R.; Park, I. C.; Pernegger, H.; Reed, C.; Remsberg, L. P.; Reuter, M.; Roland, C.; Roland, G.; Rosenberg, L.; Sagerer, J.; Sarin, P.; Sawicki, P.; Skulski, W.; Steadman, S. G.; Steinberg, P.; Stephans, G. S. F.; Stodulski, M.; Sukhanov, A.; Tang, J.-L.; Teng, R.; Trzupek, A.; Vale, C.; Nieuwenhuizen, G. J. Van; Verdier, R.; Veres, G. I.; Wadsworth, B.; Wolfs, F. L. H.; Wosiek, B.; Woźniak, K.; Wuosmaa, A. H.; Wysłouch, B.

    2006-08-01

    The PHOBOS experiment at the BNL Relativistic Heavy Ion Collider has measured the total multiplicity of primary charged particles as a function of collision centrality in Au+Au collisions at sNN= 19.6, 130, and 200 GeV. An approximate independence of / on the number of participating nucleons is observed, reminiscent of “wounded nucleon” scaling (Nch∝Npart) observed in proton-nucleus collisions. Unlike p+A, the constant of proportionality does not seem to be set by the pp/p¯p data at the same energy. Rather, there seems to be a surprising correspondence with the total multiplicity measured in e+e- annihilations, as well as the rapidity shape measured over a large range. The energy dependence of the integrated multiplicity per participant pair shows that e+e- and A+A data agree over a large range of center-of-mass energies (s>20 GeV), and pp/p¯p data can be brought to agree approximately with the e+e- data by correcting for the typical energy taken away by leading particles. This is suggestive of a mechanism for soft particle production that depends mainly on the amount of available energy. It is conjectured that the dominant distinction between A+A and p+p collisions is the multiple collisions per participant, which appears to be sufficient to substantially reduce the energy taken away by leading particles.

  17. Stereotactic Radiosurgery: Treatment of Brain Metastasis Without Interruption of Systemic Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Colette J.; Kummerlowe, Megan N.; Redmond, Kristin J. [Department of Radiation Oncology, Johns Hopkins Hospital, Baltimore, Maryland (United States); Rigamonti, Daniele [Department of Neurosurgery, Johns Hopkins Hospital, Baltimore, Maryland (United States); Johns Hopkins Aramco Healthcare, Dhahran (Saudi Arabia); Lim, Michael K. [Department of Neurosurgery, Johns Hopkins Hospital, Baltimore, Maryland (United States); Kleinberg, Lawrence R., E-mail: kleinla@jhmi.edu [Department of Radiation Oncology, Johns Hopkins Hospital, Baltimore, Maryland (United States)

    2016-06-01

    Purpose: To evaluate the prevalence, outcomes, and toxicities of concurrent delivery of systemic therapy with stereotactic radiosurgery (SRS) for treatment of brain metastases. Methods and Materials: We conducted a retrospective review of 193 patients treated at our institution with SRS without prior whole-brain radiation therapy (WBRT) for brain metastases between 2009 and 2014. Outcome metrics included administration of concurrent systemic therapy, myelosuppression, neurotoxicity, and survival. Results: One hundred ninety-three patients with a median age of 61 years underwent a total of 291 SRS treatments. Thirty-seven percent of SRS treatments were delivered concurrently with systemic therapy, of which 46% were with conventional myelosuppressive chemotherapy, and 54% with targeted and immune therapy agents. Myelosuppression was minimal after treatment with both systemic therapy and SRS, with 14% grade 3-4 toxicity for lymphopenia and 4-9% for leukopenia, neutropenia, anemia, and thrombocytopenia. Neurotoxicity was also minimal after combined therapy, with no grade 4 and <5% grade 3 toxicity, 34% dexamethasone requirement, and 4% radiation necrosis, all similar to treatments with SRS alone. Median overall survival was similar after SRS alone (14.4 months) versus SRS with systemic therapy (12.9 months). In patients with a new diagnosis of primary cancer with brain metastasis, early treatment with concurrent systemic therapy and SRS correlated with improved survival versus SRS alone (41.6 vs 21.5 months, P<.05). Conclusions: Systemic therapy can be safely given concurrently with SRS for brain metastases: our results suggest minimal myelosuppression and neurotoxicity. Concurrent therapy is an attractive option for patients who have both intracranial and extracranial metastatic disease and may be particularly beneficial in patients with a new diagnosis of primary cancer with brain metastasis.

  18. Effect of position and momentum constraints on charge distribution in heavy-ion collisions

    International Nuclear Information System (INIS)

    Rajni; Kumar, Suneel

    2012-01-01

    The rich phenomenology of multifragmentation has been widely explored after two decades of its discovery. It has been experimentally shown that in one single heavy ion collision many intermediate mass fragments (IMFs) are produced, where IMFs are defined as fragments with 5 ≤ A ≤ A tot /6. In the earlier literature, the multifragmentation was studied by Jakobsson et al. who measured the charge particle distribution along with their kinetic energy spectra in 16 O/ 36 Ar induced reaction between 25 and 200 MeV/nucleon representing the various phenomena in heavy ion collisions

  19. Place of Gamma Knife Stereotactic Radiosurgery in Grade 4 Vestibular Schwannoma Based on Case Series of 86 Patients with Long-Term Follow-Up.

    Science.gov (United States)

    Lefranc, Michel; Da Roz, Leila Maria; Balossier, Anne; Thomassin, Jean Marc; Roche, Pierre Hugue; Regis, Jean

    2018-06-01

    Grade IV vestibular schwannoma (Koos classification) is generally considered to be an indication for microsurgical resection or combined radiosurgery-microsurgery. However, the place of Gamma Knife stereotactic surgery (GK-SRS), either as first-line treatment or when progression of residual tumor compresses the brainstem, has not been clearly evaluated. This article reports the results of a large case series of patients with grade 4 vestibular schwannoma treated by GK-SRS. All consecutive patients with grade IV vestibular schwannoma treated by GK-SRS in our department between 1996 and 2011 with a minimum follow-up of 3 years were included in this study. 86 patients were treated by GK-SRS with a minimum follow-up of 3 years. Mean follow-up was 6.2 years (3-16 years). The mean age of the patients at the time of GK-SRS was 54.6 years (range: 23-84) and the sex ratio was 0.6. At the time of radiosurgery, no patient presented brainstem dysfunction prior to GK-SRS. 38 patients had functional hearing before treatment. One patient presented mild trigeminal neuralgia before GK-SRS. Tumor control with no clinical deterioration was obtained in 78 patients (90.7%). No radiation-induced brainstem or cranial nerve toxicity was observed in any of these patients. Functional hearing was maintained in 25 patients. 8 (9.3%) patients presented tumor growth and required microsurgical resection in 7 cases and ventricular shunt in 1 case. On the basis of this large series, GK-SRS appears to be a safe and effective treatment option for grade IV vestibular schwannoma for patients with no signs of brainstem dysfunction. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. An integrated logistic formula for prediction of complications from radiosurgery

    International Nuclear Information System (INIS)

    Flickinger, J.C.

    1989-01-01

    An integrated logistic model for predicting the probability of complications when small volumes of tissue receive an inhomogeneous radiation dose is described. This model can be used with either an exponential or linear quadratic correction for dose per fraction and time. Both the exponential and linear quadratic versions of this integrated logistic formula provide reasonable estimates of the tolerance of brain to radiosurgical dose distributions where there are small volumes of brain receiving high radiation doses and larger volumes receiving lower doses. This makes it possible to predict the probability of complications from stereotactic radiosurgery, as well as combinations of fractionated large volume irradiation with a radiosurgical boost. Complication probabilities predicted for single fraction radiosurgery with the Leksell Gamma Unit using 4, 8, 14, and 18 mm diameter collimators as well as for whole brain irradiation combined with a radiosurgical boost are presented. The exponential and linear quadratic versions of the integrated logistic formula provide useful methods of calculating the probability of complications from radiosurgical treatment

  1. The dynamics of a charged particle

    OpenAIRE

    Rohrlich, Fritz

    2008-01-01

    Using physical arguments, I derive the physically correct equations of motion for a classical charged particle from the Lorentz-Abraham-Dirac equations (LAD) which are well known to be physically incorrect. Since a charged particle can classically not be a point particle because of the Coulomb field divergence, my derivation accounts for that by imposing a basic condition on the external force. That condition ensures that the particle's finite size charge distribution looks like a point charg...

  2. Practical Implementation of Failure Mode and Effects Analysis for Safety and Efficiency in Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Younge, Kelly Cooper; Wang, Yizhen; Thompson, John; Giovinazzo, Julia; Finlay, Marisa; Sankreacha, Raxa

    2015-01-01

    Purpose: To improve the safety and efficiency of a new stereotactic radiosurgery program with the application of failure mode and effects analysis (FMEA) performed by a multidisciplinary team of health care professionals. Methods and Materials: Representatives included physicists, therapists, dosimetrists, oncologists, and administrators. A detailed process tree was created from an initial high-level process tree to facilitate the identification of possible failure modes. Group members were asked to determine failure modes that they considered to be the highest risk before scoring failure modes. Risk priority numbers (RPNs) were determined by each group member individually and then averaged. Results: A total of 99 failure modes were identified. The 5 failure modes with an RPN above 150 were further analyzed to attempt to reduce these RPNs. Only 1 of the initial items that the group presumed to be high-risk (magnetic resonance imaging laterality reversed) was ranked in these top 5 items. New process controls were put in place to reduce the severity, occurrence, and detectability scores for all of the top 5 failure modes. Conclusions: FMEA is a valuable team activity that can assist in the creation or restructuring of a quality assurance program with the aim of improved safety, quality, and efficiency. Performing the FMEA helped group members to see how they fit into the bigger picture of the program, and it served to reduce biases and preconceived notions about which elements of the program were the riskiest

  3. Practical Implementation of Failure Mode and Effects Analysis for Safety and Efficiency in Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Younge, Kelly Cooper, E-mail: kyounge@med.umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Wang, Yizhen [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Thompson, John; Giovinazzo, Julia; Finlay, Marisa [Department of Radiation Oncology, Trillium Health Partners - Credit Valley Hospital Site, Mississauga Halton/Central West Regional Cancer Program, Mississauga, ON (Canada); Sankreacha, Raxa [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States)

    2015-04-01

    Purpose: To improve the safety and efficiency of a new stereotactic radiosurgery program with the application of failure mode and effects analysis (FMEA) performed by a multidisciplinary team of health care professionals. Methods and Materials: Representatives included physicists, therapists, dosimetrists, oncologists, and administrators. A detailed process tree was created from an initial high-level process tree to facilitate the identification of possible failure modes. Group members were asked to determine failure modes that they considered to be the highest risk before scoring failure modes. Risk priority numbers (RPNs) were determined by each group member individually and then averaged. Results: A total of 99 failure modes were identified. The 5 failure modes with an RPN above 150 were further analyzed to attempt to reduce these RPNs. Only 1 of the initial items that the group presumed to be high-risk (magnetic resonance imaging laterality reversed) was ranked in these top 5 items. New process controls were put in place to reduce the severity, occurrence, and detectability scores for all of the top 5 failure modes. Conclusions: FMEA is a valuable team activity that can assist in the creation or restructuring of a quality assurance program with the aim of improved safety, quality, and efficiency. Performing the FMEA helped group members to see how they fit into the bigger picture of the program, and it served to reduce biases and preconceived notions about which elements of the program were the riskiest.

  4. SU-F-T-587: Quality Assurance of Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT) for Patient Specific Plans: A Comparison Between MATRIXX and Delta4 QA Devices

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, YC; Lu, SH; Chen, LH; Kuo, SH; Wang, CW [National Taiwan University Hospital, Taipei City, Taiwan (China)

    2016-06-15

    Purpose: Patient-specific quality assurance (QA) is necessary to accurately deliver high dose radiation to the target, especially for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT). Unlike previous 2 dimensional (D) array QA devices, Delta{sup 4} can verify the dose delivery in 3D. In this study, the difference between calculated and measured dose distribution was compared with two QA devices (MATRIXX and Delta{sup 4}) to evaluate the delivery accuracy. Methods: Twenty-seven SRS/SBRT plans with VMAT were verified with point-dose and dose-map analysis. We use an ion chamber (A1SL, 0.053cc) for point-dose measurement. For verification of the dose map, the differences between the calculated and measured doses were analyzed with a gamma index using MATRIXX and Delta{sup 4} devices. The passing criteria for gamma evaluation were set at 3 mm for distance-to-agreement (DTA) and 3% for dose-difference. A gamma index less than 1 was defined as the verification passing the criteria and satisfying at least 95% of the points. Results: The mean prescribed dose and fraction was 40 ± 14.41 Gy (range: 16–60) and 10 ± 2.35 fractions (range: 1–8), respectively. In point dose analysis, the differences between the calculated and measured doses were all less than 5% (mean: 2.12 ± 1.13%; range: −0.55% to 4.45%). In dose-map analysis, the average passing rates were 99.38 ± 0.96% (range: 95.31–100%) and 100 ± 0.12% (range: 99.5%–100%) for MATRIXX and Delta{sup 4}, respectively. Even using criteria of 2%/2 mm, the passing rate of Delta{sup 4} was still more than 95% (mean: 99 ± 1.08%; range: 95.6%–100%). Conclusion: Both MATRIXX and Delta{sup 4} offer accurate and efficient verification for SRS/SBRT plans. The results measured by MATRIXX and Delta{sup 4} dosimetry systems are similar for SRS/SBRT performed with the VMAT technique.

  5. Search for multiply charged Heavy Stable Charged Particles in data collected with the CMS detector

    Energy Technology Data Exchange (ETDEWEB)

    Veeraraghavan, Venkatesh [Florida State Univ., Tallahassee, FL (United States)

    2013-10-30

    Several models of new physics yield particles that are massive, long-lived, and have an electric charge, Q, greater than that of the electron, e. A search for evidence of such particles was performed using 5.0 fb-1 and 18.8 fb-1 of proton-proton collision data collected at √s = 7 TeV and √s = 8 TeV, respectively, with the Compact Muon Solenoid detector at the Large Hadron Collider. The distinctive detector signatures of these particles are that they are slow-moving and highly ionizing. Ionization energy loss and time-of- flight measurements were made using the inner tracker and the muon system, respectively. The search is sensitive to 1e ≤ |Q| ≤ 8e. Data were found to be consistent with standard model expectations and upper limits on the production cross section of these particles were computed using a Drell-Yan-like production model. Masses below 517, 687, 752, 791, 798, 778, 753, and 724 GeV are excluded for |Q| = 1e, 2e, 3e, 4e, 5e, 6e, 7e, and 8e, respectively.

  6. Search for multiply charged Heavy Stable Charged Particles in data collected with the CMS detector.

    CERN Document Server

    Veeraraghavan, Venkatesh

    Several models of new physics yield particles that are massive, long-lived, and have an electric charge, $Q$, greater than that of the electron, $e$. A search for evidence of such particles was performed using 5.0~fb$^{-1}$ and 18.8~fb$^{-1}$ of proton-proton collision data collected at $\\sqrt{s}=7~$TeV and $\\sqrt{s}=8~$TeV, respectively, with the Compact Muon Solenoid detector at the Large Hadron Collider. The distinctive detector signatures of these particles are that they are slow-moving and highly ionizing. Ionization energy loss and time-of-flight measurements were made using the inner tracker and the muon system, respectively. The search is sensitive to $1e \\leq |Q| \\leq 8e$. Data were found to be consistent with standard model expectations and upper limits on the production cross section of these particles were computed using a Drell-Yan-like production model. Masses below 517, 687, 752, 791, 798, 778, 753, and 724~GeV are excluded for $|Q|=1e$, $2e$, $3e$, $4e$, $5e$, $6e$, $7e$, and $8e$, respectivel...

  7. Analysis of neurological sequelae from radiosurgery of arteriovenous malformations: how location effects outcome

    International Nuclear Information System (INIS)

    Flickinger, John C.; Kondziolka, Douglas; Maitz, Ann H.; Lunsford, L. Dade

    1997-01-01

    Purpose/Objective: To elucidate how the risks of developing temporary and permanent neurological sequelae from radiosurgery for arteriovenous malformations (AVM) relate to AVM location, the addition of stereotactic magnetic resonance (MR) imaging to angiographic targeting, and prior hemorrhage or neurological deficits. Materials and Methods: We evaluated follow-up imaging and clinical data in 332 AVM patients who received gamma knife radiosurgery at the University of Pittsburgh between 1987 and 1994. All patients had regular clinical or imaging follow up for a minimum of two years (range: 24-96 mo., median=45 mo.). 83 patients had MR. planning, and 187 previously bled. Results: Symptomatic post-radiosurgery sequelae (any neurological problem including headache) developed in 30/332 patients (9.0%). Symptoms resolved in 58% of patients within 24 mo. with a significantly greater proportion (p=0.006) resolving in patients with Dmin <20 vs. ≥20 Gy (89 vs. 36%). The 7 yr. actuarial rate for developing persistent symptomatic sequelae was 3.8%. We first evaluated the relative risks for different locations to construct a post-radiosurgery injury expression (PIE) score for AVM location (see Table 1). Multivariate logistic regression analysis of symptomatic post-radiosurgery injury identified independent significant correlations with PIE location score (p=0.0007) and 12 Gy volume (p=0.008) but none of the other factors tested (p≥0.3) including the addition of MR targeting, average radiation dose in 20 cc, prior bleed or neurological deficit. We used these results to construct risk prediction models for any symptomatic post-radiosurgery sequelae and for symptomatic necrosis. Conclusion: The risks of complications from AVM radiosurgery can be predicted according to location with the PIE score and by the 12 Gy treatment volume (Table 2)

  8. Searches for long-lived heavy particles, HSCP, monopoles (ATLAS+CMS)

    CERN Document Server

    Lenz, Teresa

    2016-01-01

    Long-lived particles are contained in a variety of beyond Standard Model theories, including supersymmetric models, universal extra dimensions, or technicolor theories. If the lifetime of such a particle is long enough, the particle can enter - or even pass through - the detector before it decays. Therefore, searches for long-lived particles require a very different search strategy compared to conventional searches for particles beyond the Standard Model.If the new particle is not only weakly interacting, the particle can be reconstructed itself and not only via its decay products.A very specific characteristic of such new heavy charged particles is their large ionization losses when traveling through the detector.This article summarizes searches for long-lived particles at the CMS and ATLAS experiments that exploit the potentially high ionization losses per path length ($dE/dx$) of the new particle.The presented searches are performed on 8 and/or 13\\,TeV data. Additionally, an overview of the methodology of ...

  9. Analysis of the Factors Contributing to Vertebral Compression Fractures After Spine Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Boyce-Fappiano, David; Elibe, Erinma [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan (United States); Schultz, Lonni [Department of Neurosurgery, Henry Ford Health System, Detroit, Michigan (United States); Ryu, Samuel [Department of Radiation Oncology, Stony Brook University School of Medicine, Stony Brook, New York (United States); Siddiqui, M. Salim; Chetty, Indrin [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan (United States); Lee, Ian; Rock, Jack [Department of Neurosurgery, Henry Ford Health System, Detroit, Michigan (United States); Movsas, Benjamin [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan (United States); Siddiqui, Farzan, E-mail: fsiddiq2@hfhs.org [Department of Radiation Oncology, Henry Ford Health System, Detroit, Michigan (United States)

    2017-02-01

    Purpose: To determine our institutional vertebral compression fracture (VCF) rate after spine stereotactic radiosurgery (SRS) and determine contributory factors. Methods and Materials: Retrospective analysis from 2001 to 2013 at a single institution was performed. With institutional review board approval, electronic medical records of 1905 vertebral bodies from 791 patients who were treated with SRS for the management of primary or metastatic spinal lesions were reviewed. A total of 448 patients (1070 vertebral bodies) with adequate follow-up imaging studies available were analyzed. Doses ranging from 10 Gy in 1 fraction to 60 Gy in 5 fractions were delivered. Computed tomography and magnetic resonance imaging were used to evaluate the primary endpoints of this study: development of a new VCF, progression of an existing VCF, and requirement of stabilization surgery after SRS. Results: A total of 127 VCFs (11.9%; 95% confidence interval [CI] 9.5%-14.2%) in 97 patients were potentially SRS induced: 46 (36%) were de novo, 44 (35%) VCFs progressed, and 37 (29%) required stabilization surgery after SRS. Our rate for radiologic VCF development/progression (excluding patients who underwent surgery) was 8.4%. Upon further exclusion of patients with hematologic malignancies the VCF rate was 7.6%. In the univariate analyses, females (hazard ratio [HR] 1.54, 95% CI 1.01-2.33, P=.04), prior VCF (HR 1.99, 95% CI 1.30-3.06, P=.001), primary hematologic malignancies (HR 2.68, 95% CI 1.68-4.28, P<.001), thoracic spine lesions (HR 1.46, 95% CI 1.02-2.10, P=.02), and lytic lesions had a significantly increased risk for VCF after SRS. On multivariate analyses, prior VCF and lesion type remained contributory. Conclusions: Single-fraction SRS doses of 16 to 18 Gy to the spine seem to be associated with a low rate of VCFs. To the best of our knowledge, this is the largest reported experience analyzing SRS-induced VCFs, with one of the lowest event rates reported.

  10. Machine-Specific Magnetic Resonance Imaging Quality Control Procedures for Stereotactic Radiosurgery Treatment Planning.

    Science.gov (United States)

    Fatemi, Ali; Taghizadeh, Somayeh; Yang, Claus Chunli; R Kanakamedala, Madhava; Morris, Bart; Vijayakumar, Srinivasan

    2017-12-18

    Purpose Magnetic resonance (MR) images are necessary for accurate contouring of intracranial targets, determination of gross target volume and evaluation of organs at risk during stereotactic radiosurgery (SRS) treatment planning procedures. Many centers use magnetic resonance imaging (MRI) simulators or regular diagnostic MRI machines for SRS treatment planning; while both types of machine require two stages of quality control (QC), both machine- and patient-specific, before use for SRS, no accepted guidelines for such QC currently exist. This article describes appropriate machine-specific QC procedures for SRS applications. Methods and materials We describe the adaptation of American College of Radiology (ACR)-recommended QC tests using an ACR MRI phantom for SRS treatment planning. In addition, commercial Quasar MRID 3D and Quasar GRID 3D phantoms were used to evaluate the effects of static magnetic field (B 0 ) inhomogeneity, gradient nonlinearity, and a Leksell G frame (SRS frame) and its accessories on geometrical distortion in MR images. Results QC procedures found in-plane distortions (Maximum = 3.5 mm, Mean = 0.91 mm, Standard deviation = 0.67 mm, >2.5 mm (%) = 2) in X-direction (Maximum = 2.51 mm, Mean = 0.52 mm, Standard deviation = 0.39 mm, > 2.5 mm (%) = 0) and in Y-direction (Maximum = 13. 1 mm , Mean = 2.38 mm, Standard deviation = 2.45 mm, > 2.5 mm (%) = 34) in Z-direction and < 1 mm distortion at a head-sized region of interest. MR images acquired using a Leksell G frame and localization devices showed a mean absolute deviation of 2.3 mm from isocenter. The results of modified ACR tests were all within recommended limits, and baseline measurements have been defined for regular weekly QC tests. Conclusions With appropriate QC procedures in place, it is possible to routinely obtain clinically useful MR images suitable for SRS treatment planning purposes. MRI examination for SRS planning can benefit from the improved localization and planning

  11. Analysis of the Factors Contributing to Vertebral Compression Fractures After Spine Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Boyce-Fappiano, David; Elibe, Erinma; Schultz, Lonni; Ryu, Samuel; Siddiqui, M. Salim; Chetty, Indrin; Lee, Ian; Rock, Jack; Movsas, Benjamin; Siddiqui, Farzan

    2017-01-01

    Purpose: To determine our institutional vertebral compression fracture (VCF) rate after spine stereotactic radiosurgery (SRS) and determine contributory factors. Methods and Materials: Retrospective analysis from 2001 to 2013 at a single institution was performed. With institutional review board approval, electronic medical records of 1905 vertebral bodies from 791 patients who were treated with SRS for the management of primary or metastatic spinal lesions were reviewed. A total of 448 patients (1070 vertebral bodies) with adequate follow-up imaging studies available were analyzed. Doses ranging from 10 Gy in 1 fraction to 60 Gy in 5 fractions were delivered. Computed tomography and magnetic resonance imaging were used to evaluate the primary endpoints of this study: development of a new VCF, progression of an existing VCF, and requirement of stabilization surgery after SRS. Results: A total of 127 VCFs (11.9%; 95% confidence interval [CI] 9.5%-14.2%) in 97 patients were potentially SRS induced: 46 (36%) were de novo, 44 (35%) VCFs progressed, and 37 (29%) required stabilization surgery after SRS. Our rate for radiologic VCF development/progression (excluding patients who underwent surgery) was 8.4%. Upon further exclusion of patients with hematologic malignancies the VCF rate was 7.6%. In the univariate analyses, females (hazard ratio [HR] 1.54, 95% CI 1.01-2.33, P=.04), prior VCF (HR 1.99, 95% CI 1.30-3.06, P=.001), primary hematologic malignancies (HR 2.68, 95% CI 1.68-4.28, P<.001), thoracic spine lesions (HR 1.46, 95% CI 1.02-2.10, P=.02), and lytic lesions had a significantly increased risk for VCF after SRS. On multivariate analyses, prior VCF and lesion type remained contributory. Conclusions: Single-fraction SRS doses of 16 to 18 Gy to the spine seem to be associated with a low rate of VCFs. To the best of our knowledge, this is the largest reported experience analyzing SRS-induced VCFs, with one of the lowest event rates reported.

  12. Charged particle accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Ress, T I; Nolde, G V

    1974-11-25

    A charged particle accelerator is described. It is made of an enclosure arranged for channeling a stream of charged particles along a predetermined path, and propelling means juxtaposed to the enclosure for generating a magnetic field moving in a predetermined direction with respect to each point of the path, the magnetic flux vector of that field being transverse to that path at every point, which gives the particles, along said path, a velocity connected to that of the mobile field by a predetermined relation. This can be applied to the fast production of chemical compounds, to the emission of neutrons and of thermal energy, and to the production of mechanical energy for propelling space ships.

  13. Charged particle accelerator

    International Nuclear Information System (INIS)

    Ress, T.I.; Nolde, G.V.

    1974-01-01

    A charged particle accelerator is described. It is made of an enclosure arranged for channeling a stream of charged particles along a predetermined path, and propelling means juxtaposed to said enclosure for generating therein a magnetic field moving in a predetermined direction with respect to each point of said path, the magnetic flux vector of that field being transverse to that path at every point, which gives the particles, along said path, a velocity connected to that of the mobile field by a predetermined relation. This can be applied to the fast production of chemical compounds, to the emission of neutrons and of thermal energy, and to the production of mechanical energy for propelling space ships [fr

  14. Charge interaction between particle-laden fluid interfaces.

    Science.gov (United States)

    Xu, Hui; Kirkwood, John; Lask, Mauricio; Fuller, Gerald

    2010-03-02

    Experiments are described where two oil/water interfaces laden with charged particles move at close proximity relative to one another. The particles on one of the interfaces were observed to be attracted toward the point of closest approach, forming a denser particle monolayer, while the particles on the opposite interface were repelled away from this point, forming a particle depletion zone. Such particle attraction/repulsion was observed even if one of the interfaces was free of particles. This phenomenon can be explained by the electrostatic interaction between the two interfaces, which causes surface charges (charged particles and ions) to redistribute in order to satisfy surface electric equipotential at each interface. In a forced particle oscillation experiment, we demonstrated the control of charged particle positions on the interface by manipulating charge interaction between interfaces.

  15. Effect of heavy particles in low-energy light-particle processes

    International Nuclear Information System (INIS)

    Chan, L.H.; Hagiwara, T.; Ovrut, B.

    1979-01-01

    The ''decoupling theorem'' of Appelquist and Carazzone is found not always to be applicable to light-scalar-particle processes in spontaneously broken theories. If the Higgs scalar is considered to be light, then Higgs-scalar processes see the effect of heavy fermions and heavy vector gauge bosons at the one-loop level. If there is more than one scalar multiplet in a spontaneously broken gauge theory, the effect of a heavy Higgs particle in light-scalar-particle processes is significant at the tree level. In the latter case, such an effect can be absorbed completely into an effective phi 4 coupling constant, lambda/sub eff/, of the light particle provided that lambda/sub eff/ is positive definite

  16. Improved results for vestibular schwannoma radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Flickinger, J C; Kondziolka, D; Pollock, B; Lunsford, L D

    1995-07-01

    PURPOSE/OBJECTIVE: Treatment techniques in radiosurgery have changed since 1987. We reviewed patients who received radiosurgery for vestibular schwannoma to identify these changes and to investigate any differences in tumor control and complications. MATERIALS and METHODS: One hundred thirty-eight unilateral vestibular schwannoma patients with a minimum follow-up of two years after treatment with gamma knife radiosurgery between 1987 and 1992 were analyzed. The early treatment group consisted of 55 patients treated between 1987-1989 (median: tumor volume 3.63 cc, Dmin 18.1 Gy, Dmax 35.4 Gy, isocenters 2.3, follow-up 50.4 mos.). The later treatment group consisted of 83 patients treated between 1990-1992 (median: tumor volume 3.81 cc, Dmin 16.0 Gy, Dmax 31.6 Gy, isocenters 4.7, follow-up 35.8 mos.) RESULTS: Clinical tumor recurrence requiring surgical intervention occurred in one patient in each group. The overall actuarial clinical tumor control rate was 98%. Slight increases in tumor size (1 to 2 mm) were identified in five other patients not requiring intervention, because of no further tumor growth (n=4) or shrinkage (n=1). This led to an overall radiologic tumor control rate of 92% (not significantly different in either group). Compared to the early treatment group, the incidence of facial neuropathy (temporary or permanent) decreased in the later group (49% vs. 11%, p < 0.0001), as did trigeminal neuropathy (40% vs. 8%, p < 0.0001). Serviceable hearing preservation improved only slightly in the later group (27% vs. 40%, p = 0.70). CONCLUSION: We document a significant decrease in the morbidity of vestibular schwannoma radiosurgery over this time period with no decrease in the high rate of tumor control. This improvement is attributed to a) better conformal dose-planning with stereotactic MRI rather than CT, b) an increase in the number of isocenters used, and c) a reduction in the average dose administered by 2 Gy.

  17. SU-C-BRA-06: Automatic Brain Tumor Segmentation for Stereotactic Radiosurgery Applications

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y; Stojadinovic, S; Jiang, S; Timmerman, R; Abdulrahman, R; Nedzi, L; Gu, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: Stereotactic radiosurgery (SRS), which delivers a potent dose of highly conformal radiation to the target in a single fraction, requires accurate tumor delineation for treatment planning. We present an automatic segmentation strategy, that synergizes intensity histogram thresholding, super-voxel clustering, and level-set based contour evolving methods to efficiently and accurately delineate SRS brain tumors on contrast-enhance T1-weighted (T1c) Magnetic Resonance Images (MRI). Methods: The developed auto-segmentation strategy consists of three major steps. Firstly, tumor sites are localized through 2D slice intensity histogram scanning. Then, super voxels are obtained through clustering the corresponding voxels in 3D with reference to the similarity metrics composited from spatial distance and intensity difference. The combination of the above two could generate the initial contour surface. Finally, a localized region active contour model is utilized to evolve the surface to achieve the accurate delineation of the tumors. The developed method was evaluated on numerical phantom data, synthetic BRATS (Multimodal Brain Tumor Image Segmentation challenge) data, and clinical patients’ data. The auto-segmentation results were quantitatively evaluated by comparing to ground truths with both volume and surface similarity metrics. Results: DICE coefficient (DC) was performed as a quantitative metric to evaluate the auto-segmentation in the numerical phantom with 8 tumors. DCs are 0.999±0.001 without noise, 0.969±0.065 with Rician noise and 0.976±0.038 with Gaussian noise. DC, NMI (Normalized Mutual Information), SSIM (Structural Similarity) and Hausdorff distance (HD) were calculated as the metrics for the BRATS and patients’ data. Assessment of BRATS data across 25 tumor segmentation yield DC 0.886±0.078, NMI 0.817±0.108, SSIM 0.997±0.002, and HD 6.483±4.079mm. Evaluation on 8 patients with total 14 tumor sites yield DC 0.872±0.070, NMI 0.824±0

  18. Radiosurgery of pituitary adenomas

    International Nuclear Information System (INIS)

    Kida, Yoshihisa

    2008-01-01

    The efficacy and role of gamma knife (GK) in the treatment of various pituitary adenomas are described on author's experience and discussed with literature. GK subjects are 328 patients (M 126/F 202, av. age of 47.8 y) in author's hospital, and satisfactory follow-up (32-44 mo) for evaluation has been possible in 253 cases, who had tumors non-functional (129 cases), producing ACTH (23), HGH (70) and PRL (31). Stereotactic GK radiosurgery is done with navigation by Gamma Plan based on enhanced MRI images at various doses, and evaluation in the follow-up period is performed by hormonal levels and MRI which give efficacy of complete response (CR), partial response (PR), MR and standard deviation (SD)/ progressive disease (PD) on the tumor size. The overall tumor control rate is found to be 95-100%. Effectiveness (CR and PR) is found as high as 77.4% in PRL-producing tumor (marginal dose 14-32 Gy), 65% in non-functioning (15-25 Gy), 61% in ACTH (19-30 Gy) and 60% in GH (19-31 Gy), of which tendency is similar to that in literature. Even in ACTH-producing tumor, low ACTH and cortisol levels persisted with tendency of improved obese and hypertensive symptoms. GK radiosurgery has limitations in the tissue size and distance between the tumor and optic nerve/chiasm, but for the enough small tumor, it gives satisfactorily long term efficacy. (R.T.)

  19. Development of a charged particle detector array in Pelletron-LINAC facility

    International Nuclear Information System (INIS)

    John, Bency; Inkar, A.L.; Saxena, A.; Vind, R.P.; Gupta, Y.K.; Biswas, D.C.; Nayak, B.K.; Thomas, R.G.; Danu, L.S.; Choudhury, R.K.; Kailas, S.; Topkar, A.; Venkatramanan, S.; Kumar, Manish; Sunilkumar, S.

    2010-01-01

    A charged particle detector array consisting of 50 Si-CsI detector telescopes for study of heavy-ion reactions is under construction in BARC-TIFR Pelletron-LINAC facility. Developmental work carried out for the detector modules, front-end and pulse shape discrimination electronics, scattering chamber and other mechanical parts are summarized. Some new ideas developed during the course of work are pointed out. (author)

  20. Pain relief by Cyberknife radiosurgery for spinal metastasis.

    Science.gov (United States)

    Lee, Sunyoung; Chun, Mison

    2012-01-01

    To report pain relief effect in patients with spinal metastases treated with Cyberknife® and to analyze the factors associated with pain relapse after initial pain relief. We retrospectively analyzed patients with spinal metastasis treated with stereotactic body radiosurgery between April 2007 and June 2009. A total of 57 patients with 73 lesions were available for analysis with a median follow-up of 6.8 months (range, 1-30). Pain was assessed by a verbal/visual analogue scale at each visit: from 0 to 10. Pain relief was defined as a decrease of at least three levels of the pain score without an increase in analgesic use. Complete relief was defined as no analgesics or a score 0 or 1. Pain relief was achieved in 88% of the lesions, with complete relief in 51% within 7 days from the start of radiosurgery. The median duration of pain relief was 3.2 months (range, 1-30). Pain reappeared in 16 patients (27%). Spinal cord compression (P = 0.001) and performance status (P = 0.01) were predictive of pain relapse by multivariate Cox analysis. All 6 patients treated with solitary spinal metastasis experienced pain relief; 5 of them were alive without evidence of disease at a median of 16 months (range, 7-30). As previous studies have shown, our study confirms that pain relief with spinal radiosurgery is around 90%. In particular, long-term pain relief and disease control was observed in patients with solitary spinal metastasis.