WorldWideScience

Sample records for stenosis requiring permanent

  1. Complications of central venous stenosis due to permanent central venous catheters in children on hemodialysis.

    Science.gov (United States)

    Rinat, Choni; Ben-Shalom, Efrat; Becker-Cohen, Rachel; Feinstein, Sofia; Frishberg, Yaacov

    2014-11-01

    Central venous catheters are frequently used as access for hemodialysis (HD) in children. One of the known complications is central venous stenosis. Although this complication is not rare, it is often asymptomatic and therefore unacknowledged. Superior vena cava (SVC) stenosis is obviously suspected in the presence of upper body edema, but several other signs and symptoms are often unrecognized as being part of this syndrome. We describe four patients with various manifestations of central venous stenosis and SVC syndrome. These sometimes life- or organ-threatening conditions include obstructive sleep apnea, unresolving stridor, increased intracranial pressure, increased intraocular pressure, right-sided pleural effusion, protein-losing enteropathy and lymphadenopathy. The temporal relationship of these complications associated with the use of central venous catheters and documentation of venous stenosis, together with their resolution after alleviation of high venous pressure, points to a causal role. We suggest pathophysiological mechanisms for the formation of each of these complications. In patients with occlusion of the SVC, various unexpected clinical entities can be caused by high central venous pressure. As often the etiology is not obvious, a high index of suspicion is needed as in some cases prompt alleviation of the high pressure is mandatory.

  2. Permanent Lateral Deviation and Stenosis of the Cervix in an Infertile Jennet.

    Science.gov (United States)

    Quartuccio, M; Marino, G; Mannarino, C; Cristarella, S

    2016-04-01

    Congenital abnormalities of the uterus and the cervix are rare in horses, often associated with infertility, despite normal ovarian activity and sexual behaviour. An abnormality of the cervix in a 5-year-old jennet with a history of infertility was described. Clinical and ultrasound examination of the genital tract showed a normal development of the uterus with regular cyclic activity in both the ovaries. Vaginoscopy revealed a normal development of the vagina and a cervix deviated on the left side of the vagina by a thick dorsoventral fold. The lateral deviation was permanent in any stage of oestrus cycle. Furthermore, the cervical os was narrow and digital penetration was not realizable. Using a 5-mm catheter, the full penetration was not possible even during oestrus; moreover, the inoculation of fluid could be revealed in uterus by ultrasound (fluid was not present before inoculation), demonstrating a minimal patency. An abnormal and permanent lateral displacement of a stenotic cervix was suspected as the primary cause of infertility in the jennet. © 2015 Blackwell Verlag GmbH.

  3. Spinal stenosis

    International Nuclear Information System (INIS)

    Beale, S.; Pathria, M.N.; Ross, J.S.; Masaryk, T.J.; Modic, M.T.

    1988-01-01

    The authors studied 50 patients who had spinal stenosis by means of MR imaging. All patients had undergone myelography and CT. Thirty patients underwent surgery. MR imaging included T1-weighted spin echo sequences with repetition time = 600 msec, echo time = 20 (600/20) sagittal and axial sections 4 mm thick with 2 mm gap. T2-weighted 2,000/60 axial images were obtained on 14 patients. Examinations were retrospectively evaluated for central stenosis, lateral recess narrowing, and foraminal encroachment. Measurements of sagittal, interpedicular, interfacet, and recess dimensions were made at L3-5. On MR images, 20 patients had single-level and 30 had multiple-level stenosis. There was excellent agreement between modalities with central canal stenosis, but a discrepancy in six patients with bony foraminal stenosis. MR imaging was an accurate method for assessment of lumbar stenosis, but CT appears marginally better for detection of bony foraminal stenosis in certain cases

  4. A novel permanent maglev impeller TAH: most requirements on blood pumps have been satisfied.

    Science.gov (United States)

    Qian, K X; Zeng, P; Ru, W M; Yuan, H Y

    2003-07-01

    Based on the development of an impeller total artificial heart (TAH) (1987) and a permanent maglev (magnetic levitation) impeller pump (2002), as well as a patented magnetic bearing and magnetic spring (1996), a novel permanent maglev impeller TAH has been developed. The device consists of a rotor and a stator. The rotor is driven radially. Two impellers with different dimensions are fixed at both the ends of the rotor. The levitation of the rotor is achieved by using two permanent magnetic bearings, which have double function: radial bearing and axial spring. As the rotor rotates at a periodic changing speed, two pumps deliver the pulsatile flow synchronously. The volume balance between the two pumps is realized due to self-modulation property of the impeller pumps, without need for detection and control. Because the hemo-dynamic force acting on the left impeller is larger than that on the right impeller, and this force during systole is larger than that during diastole, the rotor reciprocates axially once a cycle. This is beneficial to prevent the thrombosis in the pump. Furthermore, a small flow via the gap between stator and rotor from left pump into right pump comes to a full washout in the motor and the pumps. Therefore, it seems neither mechanical wear nor thrombosis could occur. The previously developed prototype impeller TAH had demonstrated that it could operate in animal experiments indefinitely, if the bearing would not fail to work. Expectantly, this novel permanent magnetic levitation impeller TAH with simplicity, implantability, pulsatility, compatibility and durability has satisfied the most requirements on blood pumps and will have more extensive applications in experiments and clinics.

  5. Relevance of G8 scale in referring elderly patients with aortic stenosis requiring a TAVI for a geriatric consultation.

    Science.gov (United States)

    de Thézy, Albane; Lafargue, Aurélie; d'Arailh, Lydie; Dijos, Marina; Leroux, Lionel; Salles, Nathalie; Rainfray, Muriel

    2017-12-01

    Aortic stenosis (AS) may soon become a significant public health issue. Referring elderly suffering from aortic stenosis for a transcatheter aortic valve implantation (TAVI) versus surgical valve replacement might be difficult and requires a multidisciplinary staff. G8 is a geriatric screening scale for frailty, validated in oncogeriatry. We study sensibility and specificity of G8 used by cardiologists in comparison to a comprehensive geriatric assessment (CGA) performed by geriatrician. Prospective study, from February to July 2015, in Bordeaux university Hospital, France. Every elderly admitted for a TAVI had a G8 scale performed by cardiologist and CGA by a geriatrician in blind. Comorbidities were assessed using Cumulative Illness Rating Scale in his geriatric version (CIRS-G). CGA was abnormal if: MMSE value in comparison to gold-standard CGA. 49 patients were included (55.1% women, mean age 84.8 years old). Nearly half of the patients (48.96%) had multiple comorbidities (CIRS G score >3 for at least three items excluding the cardiology item). 38 CGA were abnormal (77.55%) and 41 G8 (83.67%). G8 had a sensibility of 100% (IC 95% [0.9-1]), a specificity of 72.7% (IC 95% [0.43-0.9]), a positive predictive value of 92.6% and a negative prospective value of 100% (IC: 95%). G8 scale seems to be an efficient geriatric screening tool for frailty in elderly undergoing TAVI in comparison to CGA. Simple and useful, G8 scale could be performed by cardiologists in older patients with AS for identifying patients with a geriatric risk profile in consultation before surgery. Further studies with bigger samples are needed to confirm these results.

  6. Lumbar spinal stenosis

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    Spinal stenosis, which has attracted increasing attention in recent years, represents an important group of clinical and radiologic entities. Recognition and ultimate surgical management of the many abnormalities found in this group require precise preoperative delineation of the morbid anatomy. Conventional axial tomography provided the first accurate picture of the sagittal dimension, but it was limited by poor contrast resolution. Computerized tomography and ultrasound have finally provided the means for accurate measurement of midsagittal diameter and surface area. It is now possible to provide a preoperative assessment of bony and soft-tissue canal compression and to guide surgical decompression by objective anatomic measurements. True spinal stenosis of the lumbar vertebral canal is a form of compression produced by the walls of the vertebral canal. It involves the whole of the vertebral canal by exerting compression at two of its opposite surfaces. There are two types of stenosis: (1) transport stenosis, wherein the clinical manifestations are due to impeded flow of fluid, which is dependent on the available cross-sectional area of the canal surface of the stenotic structure, and (2) compressive stenosis, which includes abnormal compression of opposing surfaces only. According to these definitions, indentation on the spinal canal by disc protrusion or localized tumor is not considered true spinal stenoses. In this chapter the authors discuss only those conditions that produce true canal stenosis

  7. 76 FR 48058 - Effective Date of Requirement for Premarket Approval for Cardiovascular Permanent Pacemaker...

    Science.gov (United States)

    2011-08-08

    ... embolism, muscle/nerve stimulation, stenosis, and erosion/extrusion may occur as a result of the clinical... advises that to ensure timely filing of any such petition, any request should be submitted to the Division... timely request for a change in the classification of this device is submitted, the Agency will, within 60...

  8. Aortic stenosis

    Science.gov (United States)

    ... Images Aortic stenosis Heart valves References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ... ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/ ...

  9. 76 FR 53851 - Effective Date of Requirement for Premarket Approval for Cardiovascular Permanent Pacemaker...

    Science.gov (United States)

    2011-08-30

    ... Pacemaker Electrode; Correction AGENCY: Food and Drug Administration, HHS. ACTION: Proposed rule; correction... preamendments device: Cardiovascular permanent pacemaker electrode. The document was published with an incorrect...

  10. Spinal stenosis

    Science.gov (United States)

    ... in the spine that was present from birth Narrow spinal canal that the person was born with Herniated or slipped disk, which ... when you sit down or lean forward. Most people with spinal stenosis cannot walk for a long ... During a physical exam, your health care provider will try to ...

  11. Effect of permanent pacemaker on mortality after transcatheter aortic valve replacement

    DEFF Research Database (Denmark)

    Engborg, Jonathan; Riechel-Sarup, Casper; Gerke, Oke

    2017-01-01

    OBJECTIVES: Transcatheter aortic valve implantation (TAVI) is an established treatment for high-grade aortic valve stenosis in patients found unfit for open heart surgery. The method may cause cardiac conduction disorders requiring permanent pacemaker (PPM) implantation, and the long-term effect...

  12. 77 FR 39924 - Effective Date of Requirement for Premarket Approval for Cardiovascular Permanent Pacemaker...

    Science.gov (United States)

    2012-07-06

    ... application (PMA) or a notice of completion of a product development protocol (PDP) for the cardiovascular... CONTACT: Melissa Burns, Center for Devices and Radiological Health, Food and Drug Administration, 10903... manufacturers, patients and insurance providers. For a new product (i.e., a cardiovascular permanent pacemaker...

  13. Permanent and induced dipole requirements in ab initio calculations of electron affinities of polar molecules

    International Nuclear Information System (INIS)

    Garrett, W.R.

    1979-01-01

    Through the use of a molecular pseudopotential method, we determine the a approximate magnitudes of errors that result when electron affinity determinations of polar negative ions are made through ab initio calculations in which the use of a given basis set yields inappropriate values for permanent and induced dipole moments of the neutral molecule. These results should prove useful in assessing the adequacy of basis sets in ab initio calculations of molecular electron affinities for simple linear polar molecules

  14. Recurred Post-intubation Tracheal Stenosis Treated with Bronchoscopic Cryotherapy

    Science.gov (United States)

    Jung, Ye-Ryung; Taek Jeong, Joon; Kyu Lee, Myoung; Kim, Sang-Ha; Joong Yong, Suk; Jeong Lee, Seok; Lee, Won-Yeon

    2016-01-01

    Post-intubation tracheal stenosis accounts for the greatest proportion of whole-cause tracheal stenosis. Treatment of post-intubation tracheal stenosis requires a multidisciplinary approach. Surgery or an endoscopic procedure can be used, depending on the type of stenosis. However, the efficacy of cryotherapy in post-intubation tracheal stenosis has not been validated. Here, we report a case of recurring post-intubation tracheal stenosis successfully treated with bronchoscopic cryotherapy that had previously been treated with surgery. In this case, cryotherapy was effective in treating web-like fibrous stenosis, without requiring more surgery. Cryotherapy can be considered as an alternative or primary treatment for post-intubation tracheal stenosis. PMID:27853078

  15. Efficacy of Surgical Airway Plasty for Benign Airway Stenosis.

    Science.gov (United States)

    Tsukioka, Takuma; Takahama, Makoto; Nakajima, Ryu; Kimura, Michitaka; Inoue, Hidetoshi; Yamamoto, Ryoji

    2016-01-01

    Long-term patency is required during treatment for benign airway stenosis. This study investigated the effectiveness of surgical airway plasty for benign airway stenosis. Clinical courses of 20 patients, who were treated with surgical plasty for their benign airway stenosis, were retrospectively investigated. Causes of stenosis were tracheobronchial tuberculosis in 12 patients, post-intubation stenosis in five patients, malacia in two patients, and others in one patient. 28 interventional pulmonology procedures and 20 surgical plasty were performed. Five patients with post-intubation stenosis and four patients with tuberculous stenosis were treated with tracheoplasty. Eight patients with tuberculous stenosis were treated with bronchoplasty, and two patients with malacia were treated with stabilization of the membranous portion. Anastomotic stenosis was observed in four patients, and one to four additional treatments were required. Performance status, Hugh-Jones classification, and ventilatory functions were improved after surgical plasty. Outcomes were fair in patients with tuberculous stenosis and malacia. However, efficacy of surgical plasty for post-intubation stenosis was not observed. Surgical airway plasty may be an acceptable treatment for tuberculous stenosis. Patients with malacia recover well after surgical plasty. There may be untreated patients with malacia who have the potential to benefit from surgical plasty.

  16. Central venous stenosis in haemodialysis patients without a previous history of catheter placement

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-01-01

    Objective: To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Material and methods: Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Results: Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Conclusion: Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term

  17. Central venous stenosis in haemodialysis patients without a previous history of catheter placement.

    Science.gov (United States)

    Oguzkurt, Levent; Tercan, Fahri; Yildirim, Sedat; Torun, Dilek

    2005-08-01

    To evaluate dialysis history, imaging findings and outcome of endovascular treatment in six patients with central venous stenosis without a history of previous catheter placement. Between April 2000 and June 2004, six (10%) of 57 haemodialysis patients had stenosis of a central vein without a previous central catheter placement. Venography findings and outcome of endovascular treatment in these six patients were retrospectively evaluated. Patients were three women (50%) and three men aged 32-60 years (mean age: 45 years) and all had massive arm swelling as the main complaint. The vascular accesses were located at the elbow in five patients and at the wrist in one patient. Three patients had stenosis of the left subclavian vein and three patients had stenosis of the left brachiocephalic vein. The mean duration of the vascular accesses from the time of creation was 25.1 months. Flow volumes of the vascular access were very high in four patients who had flow volume measurement. The mean flow volume was 2347 ml/min. One of three patients with brachiocephalic vein stenosis had compression of the vein by the brachiocephalic artery. All the lesions were first treated with balloon angioplasty and two patients required stent placement on long term. Number of interventions ranged from 1 to 4 (mean: 2.1). Symptoms resolved in five patients and improved in one patient who had a stent placed in the left BCV. Central venous stenosis in haemodialysis patients without a history of central venous catheterization tends to occur or be manifested in patients with a proximal permanent vascular access with high flow rates. Balloon angioplasty with or without stent placement offers good secondary patency rates in mid-term.

  18. Renal Branch Artery Stenosis

    DEFF Research Database (Denmark)

    Andersson, Zarah; Thisted, Ebbe; Andersen, Ulrik Bjørn

    2017-01-01

    Renovascular hypertension is a common cause of pediatric hypertension. In the fraction of cases that are unrelated to syndromes such as neurofibromatosis, patients with a solitary stenosis on a branch of the renal artery are common and can be diagnostically challenging. Imaging techniques...... that perform well in the diagnosis of main renal artery stenosis may fall short when it comes to branch artery stenosis. We report 2 cases that illustrate these difficulties and show that a branch artery stenosis may be overlooked even by the gold standard method, renal angiography....

  19. Nitinol stents in the treatment of benign proximal tracheal stenosis or tracheomalacia.

    Science.gov (United States)

    Isa, A Y; Macandie, C; Irvine, B W

    2006-01-01

    Nitinol stents have been used in the treatment of benign tracheal stenosis. A retrospective review of five patients treated at Stobhill Hospital over the last six and a half years is presented. Age at presentation ranged from 17 to 76 years. The minimum follow-up period was 23 months and the maximum was 78 months. All our patients were successfully decannulated, with none requiring recannulation. Four patients developed granulation tissue related to the stent at intervals ranging from three weeks to 41 months post stenting. Topical mitomycin C application has been useful after resection of granulations using the carbon dioxide (CO2) laser. Stent migration occurred in one patient three weeks after insertion. Nitinol stents are easy to insert and effective in the treatment of tracheal stenosis, but can have associated morbidity. Their use should be considered carefully, as insertion should be regarded as permanent. Publications reporting experience and outcome with the use of Nitinol stents in the trachea are reviewed.

  20. Mitral Valve Stenosis

    Science.gov (United States)

    ... the left ventricle from flowing backward. A defective heart valve fails to either open or close fully. Risk factors Mitral valve stenosis is less common today than it once was because the most common cause, ... other heart valve problems, mitral valve stenosis can strain your ...

  1. and Non-Operable Tracheal Stenosis

    Directory of Open Access Journals (Sweden)

    Reza Bagheri

    2013-05-01

    Full Text Available   Introduction: Tracheal stenosis is normally caused by trauma, infection, benign and malignant tumors, prolonged intubation or tracheostomy. The best treatment for tracheal stenosis is resection and anastomosis of trachea. Yet the major surgical complication of tracheal surgery is postoperative stenosis. The goal of this paper is to study the result of tracheal stenting as a replacement therapy for patients suffering from tracheal stenosis who are not good candidates for surgery.   Materials and Methods: This study presents the results of stenting in patients with: Inoperable tumoral stenosis,Non-tumoral stenosis being complicated due to prior surgeries,Inability to undergo a major surgery.The study was performed between September 2002 and July 2011 and poly flex stents were used by means of rigid bronchoscopy. Results: A total of 25 patients received stents during this study. Among them 15 patients suffered from benign and 10 suffered from malignant tracheal stenosis. The patients were followed up for at most 12 months after the stenting operation. The mean age of the patients was 35 years. The most common cause of stenosis was prolonged intubation (75%. The most common indication for stenting was the history of multiple tracheal operations. The most common complication of stenting and cause of stent removal was formation of granulation tissue. 30% of patients with benign tracheal stenosis were cured and about 10% improved until they could stand a major operation. Ten patients in benign group and 2 patients in malignant group (20% needed T-Tube insertion after stent removal but other patientcure by stenting. Conclusions: In benign cases stenting is associated with recurrence of symptoms which requires other therapeutic techniqus, so the stenting may not be named as a final solution in benign cases. However, this technique is the only method with approved efficacy for malignant cases with indication.

  2. A bronchoscopic approach to benign subglottic stenosis.

    Science.gov (United States)

    Raman, Tuhina; Chatterjee, Kshitij; Alzghoul, Bashar N; Innabi, Ayoub A; Tulunay, Ozlem; Bartter, Thaddeus; Meena, Nikhil K

    2017-01-01

    Subglottic stenosis is an abnormal narrowing of the tracheal lumen at the level of subglottis (the area in between the vocal cords and the cricoid cartilage). It can cause significant symptoms due to severe attenuation of airflow. We describe our experience in alleviating symptoms by addressing the stenosis using fibreoptic bronchoscopic methods. We report all concurrent cases performed between September 2015 and July 2016. We use a combination of balloon dilation, electro-surgery knife to dilate and incise stenotic segments followed by steroid injection to modulate healing. We treated 10 patients in the study period, 8 of which were women. A total of 39 procedures were performed on these patients during this period. Gastro-esophageal reflux was the most common comorbidity associated with stenosis. The majority of the patients required more than 2 therapeutic procedures, but none required more than 4 procedures. There were no complications. Tracheal stenosis and in particular subglottic stenosis is a recurrent process and its management requires extensive collaboration amongst treating specialties. Our technique of steroid injection after dilation of the stenosis was effective in symptom control and decreased the number of repeat procedures.

  3. Neonatal aortic stenosis.

    Science.gov (United States)

    Drury, Nigel E; Veldtman, Gruschen R; Benson, Lee N

    2005-09-01

    Neonatal aortic stenosis is a complex and heterogeneous condition, defined as left ventricular outflow tract obstruction at valvular level, presenting and often requiring treatment in the first month of life. Initial presentation may be catastrophic, necessitating hemodynamic, respiratory and metabolic resuscitation. Subsequent management is focused on maintaining systemic blood flow, either via a univentricular Norwood palliation or a biventricular route, in which the effective aortic valve area is increased by balloon dilation or surgical valvotomy. In infants with aortic annular hypoplasia but adequately sized left ventricle, the Ross-Konno procedure is also an attractive option. Outcomes after biventricular management have improved in recent years as a consequence of better patient selection, perioperative management and advances in catheter technology. Exciting new developments are likely to significantly modify the natural history of this disorder, including fetal intervention for the salvage of the hypoplastic left ventricle; 3D echocardiography providing better definition of valve morphology and aiding patient selection for a surgical or catheter-based intervention; and new transcutaneous approaches, such as duel beam echo, to perforate the valve.

  4. Permanent quadrupole magnets

    International Nuclear Information System (INIS)

    Bush, E.D. Jr.

    1976-01-01

    A family of quadrupole magnets using a soft iron return yoke and circular cross-section permanent magnet poles were fabricated to investigate the feasibility for use in ion or electron beam focusing applications in accelerators and transport lines. Magnetic field measurements yielded promising results. In fixed-field applications, permanent magnets with sufficient gradients would be a low cost substitute for conventional electromagnets, eliminating the need for power supplies, associated wiring, and cooling. Based on preliminary tests, it was seen that permanent quadrupole magnets can offer a low cost, reliable solution in applications requiring small, fixed-field focusing devices for use in ion or electron-beam transport systems. Permanent magnets do require special considerations in design, fabrication, handling, and service that are different than encountered in conventional quadrupole magnets. If these basic conditions are satisfied, the resulting beam-focusing device would be stable, maintenance free, with virtually an indefinite lifetime

  5. [Endoscopic dilatation of benign colon and rectum stenosis].

    Science.gov (United States)

    Rivera Vega, Juan; Frisancho Velarde, Oscar; Cervera, Zenón; Ruiz, Edwin; Yoza, Max; Larrea, Pedro

    2002-01-01

    To determine the usefulness of endoscopic dilatation in dealing with benign stenosis of the anus, rectum and colon. PATIENTS AND METHODS USED: Thirty six (36) patients with stenosis, anus (8), rectum (22) and colon (6) were given endoscopic treatment using hydroneumatic balloons, electro incision (radiated cuts) or a combination of both. Rigid equipment (metal) was used for distal stenosis. Age ranged between 30 and 82 years. Twelve (12) patients were male and 24 female. The diameter of the stenosis was less than 13 mm in 18 of the patients and 11 patients carried colostomy. All 36 patients were subjected to a total of 113 dilatation sessions. The average number of sessions per patient for patients with anal stenosis was 2.5 and for patients with colorectal stenosis, 3.32. One patient with rectal stenosis required 21 sessions to achieve final objective. The result achieved was good in 31 patients, less than satisfactory in 3 patients and bad in one patient, who presented a stenosis which was over 5 cm long. We lost track of a patient in the follow up stage. Success in closing the colostomy was achieved in 9 patients, while one presented a complication due to the procedure (cervical emphysema) which remitted with medical attention. Endoscopic dilatation offers, through its different techniques, a safe and efficient method for the treatment of benign stenosis of the anus, rectum and colon and must be considered as a first class tool for the treatment of this kind of pathologies.

  6. [The cause and efficacy of benign tracheal stenosis].

    Science.gov (United States)

    Su, Zhu-quan; Wei, Xiao-qun; Zhong, Chang-hao; Chen, Xiao-bo; Luo, Wei-zhan; Guo, Wen-liang; Wang, Ying-zhi; Li, Shi-yue

    2013-09-01

    To analysis the causes of benign tracheal stenosis and evaluate the curative effect of intraluminal bronchoscopic treatment. 158 patients with benign tracheal stenosis in our hospital from September 2005 to September 2012 were collected to retrospectively analysis the causes and clinic features of tracheal stenosis. Interventional treatments through bronchoscopy were used to treat the benign tracheal stenosis and the curative effects were evaluated. 158 cases of benign tracheal stenosis were recruited to our study, 69.6% of them were young and middle-aged. The main causes of benign tracheal stenosis were as follows: secondary to postintubation or tracheotomy in 61.4% (97/158), tuberculosis in 16% (26/158), benign tumor in 5.1% (8/158) and other 27 cases. 94.3% patients improved in symptoms with alleviation immediately after bronchoscopic treatment, the average tracheal diameter increased form (4.22 ± 2.06) mm to (10.16 ± 2.99) mm (t = 21.48, P benign tracheal stenosis were increasing year by year. The most common cause of benign tracheal stenosis was postintubation and tracheotomy. Interventional treatments through bronchoscopy is effective in treating benign tracheal stenosis, but repeated interventional procedures may be required to maintain the favorable long-term effects.

  7. Lumbar stenosis: clinical case

    Directory of Open Access Journals (Sweden)

    Pedro Sá

    2014-08-01

    Full Text Available Lumbar stenosis is an increasingly common pathological condition that is becoming more frequent with increasing mean life expectancy, with high costs for society. It has many causes, among which degenerative, neoplastic and traumatic causes stand out. Most of the patients respond well to conservative therapy. Surgical treatment is reserved for patients who present symptoms after implementation of conservative measures. Here, a case of severe stenosis of the lumbar spine at several levels, in a female patient with pathological and surgical antecedents in the lumbar spine, is presented. The patient underwent two different decompression techniques within the same operation.

  8. Foraminal stenosis in spondylolysis

    International Nuclear Information System (INIS)

    Greselle, J.F.; Grenier, N.; Douws, C.; Bernard, S.; Vital, J.M.; Caille, J.M.; Broussin, J.

    1989-01-01

    This paper reports eighteen patients with spondylolysis evaluated with sagittal MR imaging to correlate the factors and degree of faoraminal stenosis at the level of the lysis with clinical findings. Fifteen presented with low back pain, eight with radiculopathy and one with paresthesia in the lower limbs, and two were asymptomatic. The degree of foraminal stenosis, quantified in three grades, was not correlated with the onset of radiculopathy. Three foraminal herniations were responsible for radiculopathy. Presence of isthmic bony tip and fibrocartilage buildup were not correlated with symptoms. Foraminal compression can be demonstrated by MR imaging, but without clinical correlations

  9. Permanent education

    International Nuclear Information System (INIS)

    Gardien, S.; Kirsch, R.

    1998-01-01

    The permanent education of the IPN-Lyon inscribes itself completely in the priorities of the tri-annual plan of education of CNRS. These priorities contribute to evolution of research, evaluation of the professions, integration during the professional carriers of the personnel and form the frame for new management practice implementation

  10. Infantile hypertrophic pyloric stenosis

    DEFF Research Database (Denmark)

    Pedersen, Rikke Neess; Garne, Ester; Loane, Maria

    2008-01-01

    OBJECTIVE: The objective of this study was to present epidemiologic data on infantile hypertrophic pyloric stenosis (IHPS) from seven well-defined European regions, and to compare incidence and changes in incidence over time between these regions. METHODS: This was a population-based study using ...

  11. Lumbar spinal stenosis

    DEFF Research Database (Denmark)

    Lønne, Greger; Fritzell, Peter; Hägg, Olle

    2018-01-01

    BACKGROUND: Decompression surgery for lumbar spinal stenosis (LSS) is the most common spinal procedure in the elderly. To avoid persisting low back pain, adding arthrodesis has been recommended, especially if there is a coexisting degenerative spondylolisthesis. However, this strategy remains con...

  12. Central and foraminal stenosis of the lumbar spine

    International Nuclear Information System (INIS)

    Major, N.M.; Helms, C.A.

    1995-01-01

    The discussion include clinical presentation, anatomy, imaging techniques, central canal stenosis, iatrogenic stenosis, post-traumatic stenosis, neural foraminal stenosis, facet joint disease, lateral recess disease (15 refs.)

  13. Central and foraminal stenosis of the lumbar spine

    Energy Technology Data Exchange (ETDEWEB)

    Major, N M; Helms, C A [California Univ., San Francisco, CA (United States). Dept. of Radiology

    1996-12-31

    The discussion include clinical presentation, anatomy, imaging techniques, central canal stenosis, iatrogenic stenosis, post-traumatic stenosis, neural foraminal stenosis, facet joint disease, lateral recess disease (15 refs.).

  14. Mitral Stenosis: A Review

    Directory of Open Access Journals (Sweden)

    By C. Richard Conti, MD, MACC

    2018-01-01

    Full Text Available Mitral stenosis due to rheumatic heart disease is not common in the United States but is common in the developing world because rheumatic fever is still occurring frequently. Symptoms usually gradually occur in the young adult (most commonly female. Atrial fibrillation is a common accompanying rhythm in patients with proven mitral stenosis. The main physiologic event is a pressure gradient between the left atrium and the left ventricle. Diagnosis is relatively straight forward using physical exam and simple laboratory studies such as Chest X-Ray (elevated Left main stem bronchus, Double Density indicating enlarged left atrium and ECG (P-Mitrale. Cardiac ultrasound confirms the clinical diagnosis (Doming of mitral valve in diastole, Hockey stick deformity of the anterior mitral valve leaflet, large left atrium, Doppler estimation of valve gradient. Mitral commisurotomy (surgical or Balloon is warranted if the valve is pliable and not heavily calcified.

  15. Congenital pyriform aperture stenosis

    International Nuclear Information System (INIS)

    Osovsky, Micky; Aizer-Danon, Anat; Horev, Gadi; Sirota, Lea

    2007-01-01

    Nasal airway obstruction is a potentially life-threatening condition in the newborn. Neonates are obligatory nasal breathers. The pyriform aperture is the narrowest, most anterior bony portion of the nasal airway, and a decrease in its cross-sectional area will significantly increase nasal airway resistance. Congenital nasal pyriform aperture stenosis (CNPAS) is a rare, unusual form of nasal obstruction. It should be considered in the differential diagnosis of any neonate or infant with signs and symptoms of upper airway compromise. It is important to differentiate this level of obstruction from the more common posterior choanal stenosis or atresia. CNPAS presents with symptoms of nasal airway obstruction, which are often characterized by episodic apnea and cyclical cyanosis. (orig.)

  16. Infantile hypertrophic pyloric stenosis

    International Nuclear Information System (INIS)

    Breivik, K.; Soereide, J.A.; Bland, J.

    1990-01-01

    During an eight-year period, 40 patients were operated consecutively for pyloric stenosis. The most common symptom was projectile vomiting, which occurred in 92.5% of the cases. On examination only three patients had a palpable hypertrophic pylorus. In 39 patients a preoperative X-ray examination with contrast was necessary to confirm the diagnosis. A pyleromyotomy was performed in all patients. The diagnosis routines and the results of the treatment are discussed. 16 refs., 2 figs., 3 tabs

  17. Mesenchymal stem cell therapy for laryngotracheal stenosis

    DEFF Research Database (Denmark)

    Jakobsen, Kathrine Kronberg; Grønhøj, Christian; Jensen, David H

    2017-01-01

    BACKGROUND: Laryngotracheal stenosis (LTS) can be either congenital or acquired. Laryngeal stenosis is most often encountered after prolonged intubation. The mechanism for stenosis following intubation is believed to be hypertrophic scarring. Mesenchymal stem cells (MSCs) therapy has shown...

  18. Renal artery stenosis

    International Nuclear Information System (INIS)

    Desberg, A.; Paushter, D.M.; Lammert, G.K.; Hale, J.; Troy, R.; Novic, A.; Nally, J. Jr.

    1989-01-01

    Renal artery disease is a potentially correctable cause of hypertension. Previous studies have suggested the utility of duplex sonography in accurately detecting and grading the severity of renal artery stenosis. The purpose of this paper is to evaluate color flow Doppler for this use. Forty-three kidneys were examined by color-flow Doppler and conventional duplex sampling in patients with suspected renovascular hypertension or those undergoing aortography for unrelated reasons. Doppler tracings were obtained from the renal arteries and aorta with calculation of the renal aortic ratio (RAR) and resistive index (RI). Results of Doppler sampling with color flow guidance were compared with aortograms in a blinded fashion

  19. Renal artery stenosis.

    Science.gov (United States)

    Tafur-Soto, Jose David; White, Christopher J

    2015-02-01

    Atherosclerotic renal artery stenosis (RAS) is the single largest cause of secondary hypertension; it is associated with progressive renal insufficiency and causes cardiovascular complications such as refractory heart failure and flash pulmonary edema. Medical therapy, including risk factor modification, renin-angiotensin-aldosterone system antagonists, lipid-lowering agents, and antiplatelet therapy, is advised in all patients. Patients with uncontrolled renovascular hypertension despite optimal medical therapy, ischemic nephropathy, and cardiac destabilization syndromes who have severe RAS are likely to benefit from renal artery revascularization. Screening for RAS can be done with Doppler ultrasonography, CT angiography, and magnetic resonance angiography. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Long-term results of laryngotracheal resection for benign stenosis from a series of 109 consecutive patients.

    Science.gov (United States)

    D'Andrilli, Antonio; Maurizi, Giulio; Andreetti, Claudio; Ciccone, Anna Maria; Ibrahim, Mohsen; Poggi, Camilla; Venuta, Federico; Rendina, Erino Angelo

    2016-07-01

    Long-term results of patients undergoing laryngotracheal resection for benign stenosis are reported. This is the largest series ever published. Between 1991 and March 2015, 109 consecutive patients (64 males, 45 females; mean age 39 ± 10.9 years) underwent laryngotracheal resection for subglottic postintubation (93) or idiopathic (16) stenosis. Preoperative procedures included tracheostomy in 35 patients, laser in 17 and laser plus stenting in 18. The upper limit of the stenosis ranged between actual involvement of the vocal cords and 1.5 cm from the glottis. Airway resection length ranged between 1.5 and 6 cm (mean 3.4 ± 0.8 cm) and it was over 4.5 cm in 14 patients. Laryngotracheal release was performed in 9 patients (suprahyoid in 7, pericardial in 1 and suprahyoid + pericardial in 1). There was no perioperative mortality. Ninety-nine patients (90.8%) had excellent or good early results. Ten patients (9.2%) experienced complications including restenosis in 8, dehiscence in 1 and glottic oedema requiring tracheostomy in 1. Restenosis was treated in all 8 patients with endoscopic procedures (5 laser, 2 laser + stent, 1 mechanical dilatation). The patient with anastomotic dehiscence required temporary tracheostomy closed after 1 year with no sequelae. One patient presenting postoperative glottic oedema underwent permanent tracheostomy. Minor complications occurred in 4 patients (3 wound infections, 1 atrial fibrillation). Definitive excellent or good results were achieved in 94.5% of patients. Twenty-eight post-coma patients with neuropsychiatric disorders showed no increased complication and failure rate. Laryngotracheal resection is the definitive curative treatment for subglottic stenosis allowing very high success rate at long term. Early complications can be managed by endoscopic procedures achieving excellent and stable results over time. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio

  1. Spinal canal stenosis; Spinalkanalstenose

    Energy Technology Data Exchange (ETDEWEB)

    Papanagiotou, P.; Boutchakova, M. [Klinikum Bremen-Mitte/Bremen-Ost, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Bremen (Germany)

    2014-11-15

    Spinal stenosis is a narrowing of the spinal canal by a combination of bone and soft tissues, which can lead to mechanical compression of spinal nerve roots or the dural sac. The lumbal spinal compression of these nerve roots can be symptomatic, resulting in weakness, reflex alterations, gait disturbances, bowel or bladder dysfunction, motor and sensory changes, radicular pain or atypical leg pain and neurogenic claudication. The anatomical presence of spinal canal stenosis is confirmed radiologically with computerized tomography, myelography or magnetic resonance imaging and play a decisive role in optimal patient-oriented therapy decision-making. (orig.) [German] Die Spinalkanalstenose ist eine umschriebene, knoechern-ligamentaer bedingte Einengung des Spinalkanals, die zur Kompression der Nervenwurzeln oder des Duralsacks fuehren kann. Die lumbale Spinalkanalstenose manifestiert sich klinisch als Komplex aus Rueckenschmerzen sowie sensiblen und motorischen neurologischen Ausfaellen, die in der Regel belastungsabhaengig sind (Claudicatio spinalis). Die bildgebende Diagnostik mittels Magnetresonanztomographie, Computertomographie und Myelographie spielt eine entscheidende Rolle bei der optimalen patientenbezogenen Therapieentscheidung. (orig.)

  2. Extracorporeal shock wave lithotripsy for renal stone with infundibular stenosis

    International Nuclear Information System (INIS)

    Lee, Won Hong; Son, Soon Yong; Kang, Seong Ho; Lee, Yong Moon; Yoon, Seok Hwan

    2006-01-01

    We analyzed retrospectively our experience to evaluate an effect of extracorporeal shock wave lithotripsy (ESWL) for renal stone with infundibular stenosis. From January 2002 to August 2005, 35 patients with renal stone with infundibular stenosis were treated with ESWL. The diagnosis of infundibular stenosis was made by intravenous pyelography or retrograde pyelography. The final follow-up check was performed by simple abdominal film or computed tomography and interview after 6 months to 24 months (mean 10 months). 7 (20.0%) of 35 patients was freed completely, but Stone free rate including less than 2 mm size was 80% (28/35). 30 (85.7%) patients became asymptomatic, 4 (11.4%) patients were continued, and 1 (2.9%) patient was required the percutaneous nephrostolithotomy. Although ESWL has a low complete stone free rate, We suggest that renal stone with infundibular stenosis should be treated with ESWL, because that is likely to produce a high symptom free and low complications

  3. Extracorporeal shock wave lithotripsy for renal stone with infundibular stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Hong; Son, Soon Yong; Kang, Seong Ho; Lee, Yong Moon [Asan Medical Center, Seoul (Korea, Republic of); Yoon, Seok Hwan [Dongnam Health College, Suwon (Korea, Republic of)

    2006-06-15

    We analyzed retrospectively our experience to evaluate an effect of extracorporeal shock wave lithotripsy (ESWL) for renal stone with infundibular stenosis. From January 2002 to August 2005, 35 patients with renal stone with infundibular stenosis were treated with ESWL. The diagnosis of infundibular stenosis was made by intravenous pyelography or retrograde pyelography. The final follow-up check was performed by simple abdominal film or computed tomography and interview after 6 months to 24 months (mean 10 months). 7 (20.0%) of 35 patients was freed completely, but Stone free rate including less than 2 mm size was 80% (28/35). 30 (85.7%) patients became asymptomatic, 4 (11.4%) patients were continued, and 1 (2.9%) patient was required the percutaneous nephrostolithotomy. Although ESWL has a low complete stone free rate, We suggest that renal stone with infundibular stenosis should be treated with ESWL, because that is likely to produce a high symptom free and low complications.

  4. Biodegradable stents in benign stenosis of the esophagus

    International Nuclear Information System (INIS)

    Manova, G.

    2013-01-01

    Full text: Introduction: Benign stenosis of the esophagus can be postcorrosion peptic or postoperative. The treatment is difficult and traditionally consists of multiple dilatations. In refractory stenosis the placement of metal self-expanding stents is disputed because requiring their subsequent removal. New experience for therapeutic decision is self- degradable stents. Manipulation is a single and not requires their removal. What you will learn: Patients indicated for the treatment with self- degradable stents are with benign stenosis not suitable for balloon dilatation or bougienage dilation. The main groups are those with postcorrosion stenosis, peptic stenosis due to untreated gastroesophageal reflux disease with different prescription as well as post-surgical and post-radiation stenosis. Self-expanding stents made by monofilament polymer of polydioxanone, whose integrity and radial force remain 6-8 weeks depending on the gastric pH are used. Stents are applied in hard guide placed in the stenosis through the working channel of gastroscopy, and they are released under X-ray control. Putting is preceded by balloon dilatation due to the large diameter of the mounted stent. During the manipulations, several difficulties are encountered, which are missing in self-expanding metal stents. Discussion: Short-term results are satisfactory - Dysphagia in the patients is overcome and they recover their normal diet. The patients reported no pain. The control inspection of the 1st month showed partial degradation of the stents. On 3rd month it is set the complete degradation. Term follow-up shows resumption of dysphagia. Conclusion: Good short-term results make the use of self-degradable stents possible alternative for the treatment of the esophagus refractory stenosis. Long-term results are contradictory, still missing long enough randomized studies on this topic

  5. Intracranial arterial stenosis.

    Science.gov (United States)

    Carvalho, Marta; Oliveira, Ana; Azevedo, Elsa; Bastos-Leite, António J

    2014-04-01

    Intracranial arterial stenosis (IAS) is usually attributable to atherosclerosis and corresponds to the most common cause of stroke worldwide. It is very prevalent among African, Asian, and Hispanic populations. Advancing age, systolic hypertension, diabetes mellitus, high levels of low-density lipoprotein cholesterol, and metabolic syndrome are some of its major risk factors. IAS may be associated with transient or definite neurological symptoms or can be clinically asymptomatic. Transcranial Doppler and magnetic resonance angiography are the most frequently used ancillary examinations for screening and follow-up. Computed tomography angiography can either serve as a screening tool for the detection of IAS or increasingly as a confirmatory test approaching the diagnostic accuracy of catheter digital subtraction angiography, which is still considered the gold (confirmation) standard. The risk of stroke in patients with asymptomatic atherosclerotic IAS is low (up to 6% over a mean follow-up period of approximately 2 years), but the annual risk of stroke recurrence in the presence of a symptomatic stenosis may exceed 20% when the degree of luminal narrowing is 70% or more, recently after an ischemic event, and in women. It is a matter of controversy whether there is a specific type of treatment other than medical management (including aggressive control of vascular risk factors and antiplatelet therapy) that may alter the high risk of stroke recurrence among patients with symptomatic IAS. Endovascular treatment has been thought to be helpful in patients who fail to respond to medical treatment alone, but recent data contradict such expectation. Copyright © 2014 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  6. Circumferential tracheal resection with primary anastomosis for post-intubation tracheal stenosis: study of 24 cases.

    Science.gov (United States)

    Negm, Hesham; Mosleh, Mohamed; Fathy, Hesham

    2013-09-01

    The objective of this study is to evaluate the results of circumferential tracheal and cricotracheal resection with primary anastomosis for the treatment of post-intubation tracheal and cricotracheal stenosis. This is a retrospective analytical study. A total number of 24 patients were included in this study. The relevant preoperative, operative and postoperative records were collected and analyzed. Twenty patients were finally symptom-free reflecting an anastomosis success rate of 83.3 %. Variable grades of anastomotic restenosis occurred in 11 (45.8 %) patients, three patients were symptom-free and eight had airway obstructive symptoms. Four out of the eight patients with symptomatic restenosis were symptom-free with endoscopic dilatation while the remaining four patients required a permanent airway appliance (T-tube, tracheostomy) for the relief of airway obstruction and this group was considered as anastomotic failure. Cricoid involvement, associated cricoid resection and the type of anastomosis were the variables that had statistical impact on the occurrence of restenosis (P = 0.017, 0.017, 0.05; respectively). Tracheal resection with primary anastomosis is a safe effective treatment method for post-intubation tracheal stenosis in carefully selected patients. Restenosis does not always mean failure of the procedure since it may be successfully managed with endoscopic dilatation.

  7. Essure Permanent Birth Control

    Science.gov (United States)

    ... Prosthetics Essure Permanent Birth Control Essure Permanent Birth Control Share Tweet Linkedin Pin it More sharing options ... Print Essure is a a permanently implanted birth control device for women (female sterilization). Implantation of Essure ...

  8. Degenerative lumbosacral stenosis in dogs

    NARCIS (Netherlands)

    Suwankong, N.

    2007-01-01

    Degenerative lumbosacral stenosis (DLS) is now recognized as a significant cause of caudal lumbar pain and pelvic limb lameness in dogs. The condition includes lumbosacral intervertebral disc degeneration and protrusion, spondylosis deformans, sclerosis of the vertebral end plates, osteoarthrosis of

  9. Contemporary management of pyloric stenosis.

    Science.gov (United States)

    Jobson, Matthew; Hall, Nigel J

    2016-08-01

    Hypertrophic pyloric stenosis is a common surgical cause of vomiting in infants. Following appropriate fluid resuscitation, the mainstay of treatment is pyloromyotomy. This article reviews the aetiology and pathophysiology of hypertrophic pyloric stenosis, its clinical presentation, the role of imaging, the preoperative and postoperative management, current surgical approaches and non-surgical treatment options. Contemporary postoperative feeding regimens, outcomes and complications are also discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. The scars of time: the disappearance of peptic ulcer-related pyloric stenosis through the 20th century.

    Science.gov (United States)

    Hall, R; Royston, C; Bardhan, K D

    2014-01-01

    The changing pattern of haemorrhage and perforation from peptic ulcer disease is well documented but little is known about pyloric stenosis, the third complication of the disease. We reviewed records relating to definitive operations (with intent to cure) for peptic ulcer disease carried out in York, UK from 1929-1997. We categorised the patients as pyloric stenosis and no pyloric stenosis based on findings at operation and examined the change in total number of cases with pyloric stenosis and proportion of cases with pyloric stenosis, by year of operation and by decade of birth. To place our results in perspective, we reviewed world literature to examine rates of pyloric stenosis as a percentage of operative cases reported in other case series in the 20th century. 4178 patients were included in the analysis; 3697 without pyloric stenosis and 481 with pyloric stenosis (11.5%). Analysis by birth cohort showed that the proportion found to have pyloric stenosis at surgery fell from 17% in the first cohort (birth 1880-89) to only 2.9% in the last cohort (birth 1950-59; pulcer cases showing pyloric stenosis at operation. The reduction in pyloric stenosis over the last several decades is disproportionately greater than the change seen in peptic ulcer disease requiring surgery. Our findings suggest that this reduction in pyloric stenosis is largely the result of the changing natural history of the disease rather than due to the introduction of acid-suppressing medication.

  11. Neurological sequelae from brachiocephalic vein stenosis.

    Science.gov (United States)

    Herzig, David W; Stemer, Andrew B; Bell, Randy S; Liu, Ai-Hsi; Armonda, Rocco A; Bank, William O

    2013-05-01

    Stenosis of central veins (brachiocephalic vein [BCV] and superior vena cava) occurs in 30% of hemodialysis patients, rarely producing intracranial pathology. The authors present the first cases of BCV stenosis causing perimesencephalic subarachnoid hemorrhage and myoclonic epilepsy. In the first case, a 73-year-old man on hemodialysis presented with headache and blurry vision, and was admitted with presumed idiopathic intracranial hypertension after negative CT studies and confirmatory lumbar puncture. The patient mildly improved until hospital Day 3, when he experienced a seizure; emergency CT scans showed perimesencephalic subarachnoid hemorrhage. Cerebral angiography failed to find any vascular abnormality, but demonstrated venous congestion. A fistulogram found left BCV occlusion with jugular reflux. The occlusion could not be reopened percutaneously and required open fistula ligation. Postoperatively, symptoms resolved and the patient remained intact at 7-month follow-up. In the second case, a 67-year-old woman on hemodialysis presented with right arm weakness and myoclonic jerks. Admission MRI revealed subcortical edema and a possible dural arteriovenous fistula. Cerebral angiography showed venous engorgement, but no vascular malformation. A fistulogram found left BCV stenosis with jugular reflux, which was immediately reversed with angioplasty and stent placement. Postprocedure the patient was seizure free, and her strength improved. Seven months later the patient presented in myoclonic status epilepticus, and a fistulogram revealed stent occlusion. Angioplasty successfully reopened the stent and she returned to baseline; she was seizure free at 4-month follow-up. Central venous stenosis is common with hemodialysis, but rarely presents with neurological findings. Prompt recognition and endovascular intervention can restore normal venous drainage and resolve symptoms.

  12. Renal Transplant Ureteral Stenosis: Treatment by Self-Expanding Metallic Stent

    International Nuclear Information System (INIS)

    Cantasdemir, Murat; Kantarci, Fatih; Numan, Furuzan; Mihmanli, Ismail; Kalender, Betul

    2003-01-01

    We report the use of a metallic stent in a transplant ureteral stenosis. A 28-year-old man with chronic renal failure due to chronic pyelonephritis, who received a living-donor renal transplant, presented with transplant ureteral stenosis. The stenosis was unresponsive to balloon dilation and was treated by antegrade placement of a self-expanding Memotherm stent. The stentedureter stayed patent for 3 years. It may be reasonable to treat post-transplant ureteral stenosis resistant to balloon dilation with self-expanding metallic stents. However, long-term follow-up is required to evaluate the efficacy of this treatment

  13. Object permanence in the food-storing coal tit (Periparus ater) and the non-storing great tit (Parus major): Is the mental representation required?

    Science.gov (United States)

    Marhounová, Lucie; Frynta, Daniel; Fuchs, Roman; Landová, Eva

    2017-05-01

    Object permanence is a cognitive ability that enables animals to mentally represent the continuous existence of temporarily hidden objects. Generally, it develops gradually through six qualitative stages, the evolution of which may be connected with some specific ecological and behavioral factors. In birds, the advanced object permanence skills were reported in several storing species of the Corvidae family. In order to test the association between food-storing and achieved performance within the stages, we compared food-storing coal tits (Periparus ater) and nonstoring great tits (Parus major) using an adapted version of Uzgiris & Hunt's Scale 1 tasks. The coal tits significantly outperformed the great tits in searching for completely hidden objects. Most of the great tits could not solve the task when the object disappeared completely. However, the upper limit for both species is likely to be Stage 4. The coal tits could solve problems with simply hidden objects, but they used alternative strategies rather than mental representation when searching for completely hidden objects, especially if choosing between two locations. Our results also suggest that neophobia did not affect the overall performance in the object permanence tasks. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  14. Bronchology Treatment Of The Malignant Airway Stenosis

    International Nuclear Information System (INIS)

    Slivka, R. et al

    2007-01-01

    Central airway stenosis is benign or malignant etiology. Multidiscplinary approach is useful in treatment central airway stenosis. In inoperable cases, interventional bronchology is good therapeutic alternative. We can use NdYAG laser, argon plasma coagulation, elektrocautery, cryotherapy, photodynamic therapy and stents for obstruction release. In malignant stenosis, we combine often methods of the interventional bronchology with brachytherapy, chemotherapy and external radiotherapy. (author)

  15. The diastal urethral stenosis in female children

    International Nuclear Information System (INIS)

    Pauer, W.

    1985-01-01

    The distal urethral stenosis in female children is a pathological reality. It is represented by the hymenal hood, the meatal stenosis and the distal urethral ring. Diagnosis and localisation of the stenosis is maintained by calibration with bougies a boule. Therapeutical consequences are: internal urethrotomy, bilateral meatotomy and excision of hymenal hoods. (Author)

  16. Marxism as permanent revolution

    NARCIS (Netherlands)

    van Ree, E.

    2013-01-01

    This article argues that the 'permanent revolution' represented the dominant element in Karl Marx and Friedrich Engels' political discourse, and that it tended to overrule considerations encapsulated in 'historical materialism'. In Marx and Engels's understanding, permanent revolution did not

  17. Two cases of severe tracheal stenosis due to advanced adenoid cystic carcinoma of the trachea

    Energy Technology Data Exchange (ETDEWEB)

    Yuasa, Hiroshi; Akaogi, Eiichi; Morita, Riichiro; Onizuka, Masataka; Mitsui, Kiyofumi [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine; Tsuji, Hirohiko

    1991-12-01

    Two cases of severe tracheal stenosis due to advanced nonresectable adenoid cystic carcinoma of the trachea were reported. Case 1 was a 38-year-old male who underwent emergency {sup 60}Co irradiation following endoscopic YAG laser irradiation. This approach was quite effective. Proton irradiation was effective against tumor recurrence. Case 2 was a 28-year-old female in whom emergency treatment for tracheal obstruction due to edema after laser therapy necessitated transient tracheal intubation. The tracheal stenosis due to recurrent tumor after {sup 60}Co irradiation was improved by insertion of an intraluminal permanent stent. (author).

  18. Partial Facetectomy for Lumbar Foraminal Stenosis

    Directory of Open Access Journals (Sweden)

    Kevin Kang

    2014-01-01

    Full Text Available Background. Several different techniques exist to address the pain and disability caused by isolated nerve root impingement. Failure to adequately decompress the lumbar foramen may lead to failed back surgery syndrome. However, aggressive treatment often causes spinal instability or may require fusion for satisfactory results. We describe a novel technique for decompression of the lumbar nerve root and demonstrate its effectiveness in relief of radicular symptoms. Methods. Partial facetectomy was performed by removal of the medial portion of the superior facet in patients with lumbar foraminal stenosis. 47 patients underwent the procedure from 2001 to 2010. Those who demonstrated neurogenic claudication without spinal instability or central canal stenosis and failed conservative management were eligible for the procedure. Functional level was recorded for each patient. These patients were followed for an average of 3.9 years to evaluate outcomes. Results. 27 of 47 patients (57% reported no back pain and no functional limitations. Eight of 47 patients (17% reported moderate pain, but had no limitations. Six of 47 patients (13% continued to experience degenerative symptoms. Five of 47 patients (11% required additional surgery. Conclusions. Partial facetectomy is an effective means to decompress the lumbar nerve root foramen without causing spinal instability.

  19. Venous sinus stenting for pseudotumour cerebri with venous sinus stenosis

    International Nuclear Information System (INIS)

    Chen Huairui; Bai Rulin; Wu Xiaojun; Qi Xiangqian; Mei Qiyong; Lu Yicheng

    2011-01-01

    Objective: To explore the relation between venous sinus stenosis and pseduotumour cerebri and to discuss the efficacy and strategy of venous sinus stenting for its treatment. Methods: Venous sinus stenting was performed in a total of 9 patients with pseudotumour cerebri accompanied by dural sinus stenosis. The clinical data, including the clinical presentations, intracranial pressure, angiographic findings, pressure of dural sinus,methods of treatment and the therapeutic results, were retrospectively analyzed. Results: Bilateral disc edema was seen in all patients. The pressure gradient in the lateral sinuses was obviously high before stenting (22.67±7.25)mmHg in all patients and a reduction in intra-sinus pressure and pressure gradient was also found (5.78±3.77)mmHg. The symptoms associated with intracranial hypertension were gradually improved or disappeared in two weeks after the placement of the stent in all cases, and the intracranial pressure dropped evidently (12.78±5.97)cm H 2 O. Vision was improved in 7 cases at three months, whereas it remained poor in 2 cases despite normalized intracranial pressure. There was no other permanent procedure-related morbidity. The patients were followed up for 3 months to 5 years, and no recurrence developed. Conclusion: Lateral sinus stenting is an effective method for the treatment of pseudotumour cerebri with dural sinus stenosis. (authors)

  20. Bronchoscopic Treatment in the Management of Benign Tracheal Stenosis: Choices for Simple and Complex Tracheal Stenosis.

    Science.gov (United States)

    Dalar, Levent; Karasulu, Levent; Abul, Yasin; Özdemir, Cengiz; Sökücü, Sinem Nedime; Tarhan, Merve; Altin, Sedat

    2016-04-01

    Bronchoscopic treatment is 1 of the treatment choices for both palliative and definitive treatment of benign tracheal stenosis. There is no consensus on the management of these patients, however, especially patients having complex stenoses. The aim of the present study was to assess, in the largest group of patients with complex stenoses yet reported, which types of tracheal stenosis are amenable to optimal management by bronchoscopic treatment. The present study was a retrospective cohort study including 132 consecutive patients with benign tracheal stenoses diagnosed between August 2005 and January 2013. The mean age of the study population was 52 ± 18 years; 62 (47%) were women and 70 (53%) were men. Their lesions were classified as simple and complex stenoses. Simple stenoses (n = 6) were treated with 12 rigid and flexible bronchoscopic procedures (mean of 2 per patient); 5 stents were placed. The total success rate was 100%. Among the 124 complex stenoses, 4 were treated directly with surgical intervention. In total, 481 rigid and 487 flexible bronchoscopic procedures were performed in these patients. In this group, the success rate was 69.8%. From the present study, we propose that after accurate classification, interventional bronchoscopic management may have an important role in the treatment of benign tracheal stenosis. Bronchoscopic treatment should be considered as first-line therapy for simple stenoses, whereas complex stenoses need a multidisciplinary approach and often require surgical intervention. However, bronchoscopic treatment may be a valid conservative approach in the management of patients with complex tracheal stenosis who are not eligible for operative treatment. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. MANAGEMENT OF LUMBAR SPINAL CANAL STENOSIS

    Directory of Open Access Journals (Sweden)

    Mukhergee G. S

    2016-06-01

    Full Text Available BACKGROUND Spinal stenosis is one of the most common conditions in the elderly. It is defined as a narrowing of the spinal canal. The term stenosis is derived from the Greek word for narrow, which is “Stenos”. The first description of this condition is attributed to Antoine portal in 1803. Verbiest is credited with coining the term spinal stenosis and the associated narrowing of the spinal canal as its potential cause. [1-10] Kirkaldy–Willis subsequently described the degenerative cascade in the lumbar spine as the cause for the altered anatomy and pathophysiology in spinal stenosis. [11-15] If compression does not occur, the canal should be described as narrow but not stenotic. Some studies defined lumbar spinal stenosis as a “narrowing of the osteoligamentous vertebral canal and/or the intervertebral foramina causing compression of the thecal sac and/or the caudal nerve roots; at a single vertebral level, narrowing may affect the whole canal or part of it” (Postacchini 1983. This definition distinguished between disc herniation and stenosis. [16] . The most common type of spinal stenosis is caused by degenerative arthritis of the spine. Hypertrophy and ossification of the posterior longitudinal ligament which usually are confined to the cervical spine, and diffuse idiopathic skeletal hyperostosis (DISH syndrome also may result in an acquired form of spinal stenosis. Congenital forms caused by disorders such as achondroplasia and dysplastic spondylolisthesis are much less common. Congenital spinal stenosis usually is central and is evident or imaging studies. Idiopathic congenital narrowing usually involves the anteroposterior dimension of the canal secondary to short pedicles; the patient otherwise is normal. In contrast, in achondroplasia, the canal is narrowed in the anteroposterior plane owing to shortened pedicles and in lateral dimension because of diminished interpedicular distance. Acquired forms of spinal stenosis usually are

  2. Reactor safety review of permanent changes

    International Nuclear Information System (INIS)

    Lam, K.F.

    1997-01-01

    Operational compliance engineers review all changes as part of a change control process. Each change, permanent or temporary, is required to undergo an intricate review process to ensure that the benefits associated with the change outweigh the risk. For permanent changes, it is necessary to ensure that the proposed design meets the nuclear safety requirements, conforms to the licensing requirements and complies with regulatory requirements. In addition, during installation of the permanent change and prior to in-service, a configuration management process is in place to align the change with operating and maintenance documents. (author)

  3. Long-term Outcome of Short Metallic Stents for Lobar Airway Stenosis.

    Science.gov (United States)

    Fruchter, Oren; Abed El Raouf, Bayya; Rosengarten, Dror; Kramer, Mordechai R

    2017-07-01

    Whereas stents are considered an excellent treatment for proximal central major airway stenosis, the value of stenting for distal lobar airway stenosis is still controversial. Our aim was to explore the short-term and long-term outcome of metallic stents placed for benign and malignant lobar airway stenosis. Between July 2007 and July 2014, 14 patients underwent small airway stent insertion. The clinical follow-up included serial semiannual physical examinations, pulmonary function tests, imaging, and bronchoscopy. The etiologies for airway stenosis were: early post-lung transplantation bronchial stenosis (N=5), sarcoidosis (N=1), amyloidosis (N=1), anthracofibrosis (N=1), right middle lobe syndrome due to external lymph node compression (N=1), lung cancer (N=4), and stenosis of the left upper lobe of unknown etiology (N=1). Stents were placed in the right upper lobe bronchus (N=2), right middle lobe bronchus (N=6), left upper lobe bronchus (N=4), linguar bronchus (N=1), and left lower lobe bronchus (N=1). The median follow-up period ranged from 2 to 72 months (median 18 mo). Immediate relief of symptoms was achieved in the vast majority of patients (13/14, 92%). Out of 10 patients with benign etiology for stenosis, 9 (90%) experienced sustained and progressive improvement in pulmonary function tests and clinical condition. We describe our positive experience with small stents for lobar airway stenosis; further prospective trials are required to evaluate the value of this novel modality of treatment.

  4. Primary balloon angioplasty for symptomatic, high-grade intracranial stenosis.

    Science.gov (United States)

    Tomycz, Luke; Bansal, Neil K; Lockney, Tim; Strothers, Megan; Connors, John J; Shay, Scott; Singer, Robert J

    2013-01-01

    In light of recent controversy about the safety and efficacy of intracranial stenting, we sought to evaluate our experience with primary balloon angioplasty for symptomatic, high-grade intracranial stenosis. All intracranial angioplasty cases performed at Vanderbilt University Medical Center from 2006 to 2011 were retrospectively reviewed for degree of stenosis pre- and post-procedure. Immediate peri-procedural complications were evaluated as well as one-month and long-term outcomes. A total of 26 patients were included in the study with a mean age of 63.0 years and a mean follow-up of 350.2 days. The average pre-procedure stenosis was 71.2%. The immediate, average post-procedure stenosis was 46.6%, and the average post-procedure stenosis at last angiographic follow-up was 44.5%. Retreatment was required in only 3.8% of patients. The primary end-point of major stroke or death at 30 days was observed in 11.5%, and the overall intra-procedural complication rate was 7.7%. The incidence of stroke or death at last follow-up was 15.4%, which is comparable to the one-year stroke or death rate in the medical arm of the SAMPRISS trial. In this retrospective series, primary balloon angioplasty was found to be effective as a treatment option for symptomatic intracranial stenosis with the risk of stroke or death at 30 days higher than the medical arm of SAMPRIS but lower than the stenting arm. The one-year risk of stroke was comparable to that reported for the one-year outcomes in the SAMPRISS medical arm.

  5. Association Between Gout and Aortic Stenosis.

    Science.gov (United States)

    Chang, Kevin; Yokose, Chio; Tenner, Craig; Oh, Cheongeun; Donnino, Robert; Choy-Shan, Alana; Pike, Virginia C; Shah, Binita D; Lorin, Jeffrey D; Krasnokutsky, Svetlana; Sedlis, Steven P; Pillinger, Michael H

    2017-02-01

    An independent association between gout and coronary artery disease is well established. The relationship between gout and valvular heart disease, however, is unclear. The aim of this study was to assess the association between gout and aortic stenosis. We performed a retrospective case-control study. Aortic stenosis cases were identified through a review of outpatient transthoracic echocardiography (TTE) reports. Age-matched controls were randomly selected from patients who had undergone TTE and did not have aortic stenosis. Charts were reviewed to identify diagnoses of gout and the earliest dates of gout and aortic stenosis diagnosis. Among 1085 patients who underwent TTE, 112 aortic stenosis cases were identified. Cases and nonaortic stenosis controls (n = 224) were similar in age and cardiovascular comorbidities. A history of gout was present in 21.4% (n = 24) of aortic stenosis subjects compared with 12.5% (n = 28) of controls (unadjusted odds ratio 1.90, 95% confidence interval 1.05-3.48, P = .038). Multivariate analysis retained significance only for gout (adjusted odds ratio 2.08, 95% confidence interval 1.00-4.32, P = .049). Among subjects with aortic stenosis and gout, gout diagnosis preceded aortic stenosis diagnosis by 5.8 ± 1.6 years. The age at onset of aortic stenosis was similar among patients with and without gout (78.7 ± 1.8 vs 75.8 ± 1.0 years old, P = .16). Aortic stenosis patients had a markedly higher prevalence of precedent gout than age-matched controls. Whether gout is a marker of, or a risk factor for, the development of aortic stenosis remains uncertain. Studies investigating the potential role of gout in the pathophysiology of aortic stenosis are warranted and could have therapeutic implications. Published by Elsevier Inc.

  6. Radiologic spectrum of rectal stenosis

    International Nuclear Information System (INIS)

    Yamamoto, T.; Hayashi, N.; Ishii, Y.; Hayakawa, K.; Nishimura, K.

    2000-01-01

    Rectal stenosis is a common condition caused by a wide variety of diseases, including both intrinsic and extrinsic disorders, as well as both malignant and benign pathologies. Barium enema, CT, and MRI are the primary modalities for the evaluation of the disease, and careful observation of the characteristic radiologic features usually leads to correct diagnosis. However, some of the lesions looks very similar and are difficult to differentiate from each other. The purpose of this study is to review the literature on diseases that cause rectal stenosis, to clarify the characteristics of radiologic features, and to suggest the limitations in differential diagnosis. Deliberate analysis of these imaging features and correlation with clinical manifestations can facilitate a more specific diagnosis. (orig.)

  7. Radiologic spectrum of rectal stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, T.; Hayashi, N.; Ishii, Y. [Department of Radiology, Fukui Medical University School of Medicine, Matsuoka-cho, Yoshida-gun, Fukui (Japan); Hayakawa, K.; Nishimura, K. [Department of Radiology, Kyoto City Hospital, Mibu, Nakagyo-ku, Kyoto (Japan)

    2000-08-01

    Rectal stenosis is a common condition caused by a wide variety of diseases, including both intrinsic and extrinsic disorders, as well as both malignant and benign pathologies. Barium enema, CT, and MRI are the primary modalities for the evaluation of the disease, and careful observation of the characteristic radiologic features usually leads to correct diagnosis. However, some of the lesions looks very similar and are difficult to differentiate from each other. The purpose of this study is to review the literature on diseases that cause rectal stenosis, to clarify the characteristics of radiologic features, and to suggest the limitations in differential diagnosis. Deliberate analysis of these imaging features and correlation with clinical manifestations can facilitate a more specific diagnosis. (orig.)

  8. Statins for aortic valve stenosis

    Directory of Open Access Journals (Sweden)

    Luciana Thiago

    Full Text Available ABSTRACT BACKGROUND: Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. OBJECTIVES: To evaluate the effectiveness and safety of statins in aortic valve stenosis. METHODS: Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL, MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions. Selection criteria: Randomized controlled clinical trials (RCTs comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity, freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life. Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. MAIN RESULTS: We included four RCTs with 2360 participants comparing statins (1185 participants with placebo (1175 participants. We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD -0.54, 95% confidence interval (CI -1.88 to 0.80; participants = 1935; studies = 2, valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2

  9. Statins for aortic valve stenosis.

    Science.gov (United States)

    Thiago, Luciana; Tsuji, Selma Rumiko; Nyong, Jonathan; Puga, Maria Eduarda Dos Santos; Góis, Aécio Flávio Teixeira de; Macedo, Cristiane Rufino; Valente, Orsine; Atallah, Álvaro Nagib

    2016-01-01

    Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. To evaluate the effectiveness and safety of statins in aortic valve stenosis. Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions.Selection criteria: Randomized controlled clinical trials (RCTs) comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity), freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life.Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO) was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. We included four RCTs with 2360 participants comparing statins (1185 participants) with placebo (1175 participants). We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD) -0.54, 95% confidence interval (CI) -1.88 to 0.80; participants = 1935; studies = 2), valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2), and aortic jet velocity (MD -0.06, 95% CI -0.26 to 0

  10. Doppler evaluation of valvular stenosis

    International Nuclear Information System (INIS)

    Kisslo, J.; Krafchek, J.; Adams, D.; Mark, D.B.

    1986-01-01

    One of the reasons why use of Doppler echocardiography is growing rapidly is because of its utility in detecting the presence of valvular stenosis and in estimating its severity. Detection of the presence of stenotic valvular heart disease using Doppler echocardiography was originally described over 10 years ago. It has been demonstrated that Doppler blood velocity data could be used to estimate the severity of a stenotic lesion. This chapter discusses the evaluation of valvular stenois using Doppler

  11. Alkaptonuria-associated aortic stenosis.

    Science.gov (United States)

    Lok, Zoe S Y; Goldstein, Jacob; Smith, Julian A

    2013-07-01

    Alkaptonuria is an autosomal recessive disorder of tyrosine metabolism, which results in accumulation of unmetabolized homogentisic acid and its oxidized product in various tissues, including the heart. Cardiovascular involvement is a rare but serious complication of the disease. We present two patients who have undergone successful aortic valve replacement for alkaptonuria-associated aortic stenosis along with a review of the literature. © 2013 Wiley Periodicals, Inc.

  12. The permanent process

    DEFF Research Database (Denmark)

    Møller, Jesper; McCullagh, Peter

    We extend the boson process first to a large class of Cox processes and second an even larger class of infinitely divisible point processes. Density and moment results are studied in detail. These results are obtained in closed form as weighted permanents, so the extension is called a permanent...... process. Temporal extensions and a particularly tractable case of the permanent process are also studied. Extensions of the ferminon process along similar lines, leading to so-called determinant processes, are discussed at the end. While the permanent process is attractive, the determinant process...

  13. Hypertrophic Pyloric stenosis: Pre- and post-operative sonographic findings

    International Nuclear Information System (INIS)

    Park, Joung Suk; Han, Douk Sub; Oh, Jong Sub; Kim, Min Jung; Gi, Joo Yun; Park, Byung Ran; Kim, Se Jong; Koh, Kang Suk; Kim, Byung Kun

    1993-01-01

    The authors retrospectively analysed the ultrasonographic findings of 43 cases of surgically confirmed hypertrophic pyloric stenosis and their postoperative findings of sonograms taken at 1 month(n=40) or 3 month(n=5) after pyloromyotomy. In preoperative study, the thickened pyloric muscle was isoechoic or slight hypoechoic relative to liver on the midline longitudinal view and appeared as a 'nonuniform acoustic ring' on the transverse view. The results of measurement in the all cases with hypertrophic pyloric stenosis were the pyloric muscle thickness ≥ 3.8 mm, the pyloric diameter ≥ 14 mm, the pyloric channel length ≥ 16 mm, the pyloric muscle volume ≥ 2.21 cm 3 and the pyloric muscle index ≥ 0.57, respectively. It usually required 1 month after operation for the hypertrophied muscle to resolve in 36 of 41 patients. The normalized pyloric muscle appeared more hypoechoic than that of adjacent parenchyma, and the nonuniform echogenicity of the pyloric muscle disappeared. Five patients whose hypertrophied muscle did not return to normal range on 1 month's follow-up sonogram were follow-up 3 months later again, and we have ascertained their resolution in all of them. In conclusion, the pre-operative sonographic findings of infantile hypertrophic pyloric stenosis were different quantitatively and qualitatively from of those of post-operative follow-up ultrasound exam. High-resolution real time sonography is a safe and accurate method for the diagnosis of hypertrophic pyloric stenosis and useful in postpyloromyotomy follow-up

  14. Familial aggregation and heritability of pyloric stenosis

    DEFF Research Database (Denmark)

    Krogh, Camilla; Fischer, Thea K; Skotte, Line

    2010-01-01

    stenosis from monozygotic twins to fourth-generation relatives according to sex and maternal and paternal contributions and to estimate disease heritability. DESIGN, SETTING, AND PATIENTS: Population-based cohort study of 1,999,738 children born in Denmark between 1977 and 2008 and followed up.......51-4.99) for half-cousins. We found no difference in rate ratios for maternal and paternal relatives of children with pyloric stenosis and no difference according to sex of cohort member or sex of relative. The heritability of pyloric stenosis was 87%. CONCLUSION: Pyloric stenosis in Danish children shows strong...... familial aggregation and heritability....

  15. Radioelement gauges. Appliances intended for permanent installation

    International Nuclear Information System (INIS)

    1975-08-01

    The present norm defines for radioelement gauges intended for permanent installation: a classification of instruments and beam shutter devices; recommended construction techniques which satisfy health physics requirements; monitoring and test methods; information which must appear on the instruments [fr

  16. Research progress of biodegradable stent in the application for benign luminal stenosis

    International Nuclear Information System (INIS)

    Zhu Yueqi; Cheng Yingsheng; Li Minghua

    2008-01-01

    Stent implantation plays an significant role in the interventional therapy, mainly with permanent stent, possessing many disadvantages such as restenosis and inflammatory hyperplasia and can thus hardly be used in children and nonmalignant stenosis. Biodegradable stent has theoretical capability to solve these problems and acquires a bright future. Nowadays, with the development of material industry and manufacture craft, biodegradable stent technique has turned up to be mature in last decades. Through the strict animal experiments and prophase of clinic application, satisfactory result has been acquired. We believe that bioabsorbable stent will be widely used in many benign diseases which would be a good supplement for permanent stent in the near future. (authors)

  17. [Subglottic stenosis as the initial manifestation of Wegener's granulomatosis in a teenager. Case report].

    Science.gov (United States)

    Cuestas, Giselle; Rodríguez, Verónica; Doormann, Flavia; Pringe, Alejandra; Bellia Munzón, Patricio; Bellia Munzón, Gastón; Ortega, Carlos; Álvarez, Rubén

    2017-04-01

    Wegener's granulomatosis is a necrotizing granulomatous vasculitis of autoimmune origin that primarily affects the upper and lower airways and kidneys. It is very rare in children and adolescents. When started at a young age it is often associated with subglottic stenosis. Subglottic stenosis is a potentially fatal manifestation of Wegener's granulomatosis. Its diagnosis requires a high index of suspicion since it might develop in the absence of other signs of activity. Occasionally, subglottic stenosis may present as the initial manifestation of the disease. Diagnosis is confirmed by endoscopic visualization of the lesion. The treatment is complex, and it often requires repeated interventions due to restenosis. We present a 13-year-old patient with subglottic stenosis secondary to Wegener's granulomatosis. We describe the clinical manifestations, diagnosis and treatment of this rare cause of respiratory distress in the pediatric population. Sociedad Argentina de Pediatría.

  18. Undersedation is a risk factor for the development of subglottic stenosis in intubated children,

    Directory of Open Access Journals (Sweden)

    Cláudia Schweiger

    Full Text Available Abstract Objective: To analyze the level of sedation in intubated children as a risk factor for the development of subglottic stenosis. Methods: All patients between 30 days and 5 years of age who required endotracheal intubation in the pediatric intensive care unit between 2013 and 2014 were included in this prospective study. They were monitored daily and COMFORT-B scores were obtained. Flexible fiber-optic laryngoscopy was performed within eight hours of extubation, and repeated seven to ten days later if the first examination showed moderate to severe laryngeal injuries. If these lesions persisted and/or if the child developed symptoms in the follow-up period, microlaryngoscopy under general anesthesia was performed to evaluate for subglottic stenosis. Results: The study included 36 children. Incidence of subglottic stenosis was 11.1%. Children with subglottic stenosis had a higher percentage of COMFORT-B scores between 23 and 30 (undersedated than those who did not develop subglottic stenosis (15.8% vs. 3.65%, p = 0.004. Conclusion: Children who developed subglottic stenosis were less sedated than children who did not develop subglottic stenosis.

  19. Fixed cord in spinal stenosis

    International Nuclear Information System (INIS)

    Levy, L.M.; Wang, H.; Francomano, C.; Hurko, O.; Carson, B.; Heffez, D.S.; DiChiro, G.; Bryan, R.N.

    1990-01-01

    This paper evaluates patients with cervical spinal canal compromise due to congenital anomalies (achondroplasia, Chiari malformation) and degenerative diseases using MR cord motion and cerebrospinal fluid (CSF) flow studies. Pulsatile longitudinal motion of the cervical cord was determined by means of cardiac-gated velocity phase contrast methods, including cine. Pathology included dwarfism (n = 15), Chiari malformation (n = 10), spondylosis (n = 10), and acute cord compression (n = 9). Symptomatic cases of congenital cervical stenosis had decreased cord motion, although CSF flow was not always significantly compromised. Postoperative cases demonstrated good cord and CSF motion, unless compression or obstruction was present

  20. Idiopathic hypertrophic subaortic stenosis. I

    International Nuclear Information System (INIS)

    Kvam, G.

    1980-01-01

    Biplane left ventricular cineangiographies in 4 patients with typical obstructive idiopathic hypertrophic subaortic stenosis (IHSS) and in control patients with normal left ventricles were analysed. In the protruding hypertrophic muscular interventricular septum of IHSS a markedly reduced shortening occurs in either direction during the systolic contraction. It does not bend towards the right ventricle. It is suggested that the septum of IHSS acts as a suspender during the systolic contraction, thereby accounting for the fast stroke volume ejection and the high ejection fraction of IHSS. (Auth.)

  1. A case of William's syndrome associated peripheral pulmonary arterial stenosis

    International Nuclear Information System (INIS)

    Jung, Kyung Hwa; Hwang, Mi Soo; Kim, Sun Yong; Chang, Jae Chun; Park, Bok Hwan

    1988-01-01

    William's syndrome, in order to more completely delineate the total spectrum of the disorder, indicates that 'infantile hypercalcemia', 'peculiar facies' and 'supravalvular aortic stenosis.' In has other many vascular anomalies, such as peripheral pulmonary arterial stenosis, coronary arterial stenosis, celiac arterial stenosis, and renal aterial stenosis. Only 32% of the patients have evidence of supravalvular aortic stenosis. And it is very rare disease entity that has been reported rarely in Korea. Recently authors experienced a case that was questioned William's syndrome with peripheral pulmonary arterial stenosis, clinically and preliminary radiologically and this case was confirmed by operation. Here we report a case of William's syndrome with peripheral pulmonary arterial stenosis and reviewed literatures

  2. Severe aortic stenosis: diagnosis, treatment and prognosis

    NARCIS (Netherlands)

    M.W.A. van Geldorp (Martijn)

    2013-01-01

    textabstractDegenerative aortic stenosis is the most common valvular heart disease in developed countries. The prevalence of severe aortic stenosis increases with age from 1% in people below 65 years of age to nearly 6% in people over the age of 85. Since the population life expectancy continues to

  3. Contemporary Management of Idiopathic Laryngotracheal Stenosis.

    Science.gov (United States)

    Donahoe, Laura; Keshavjee, Shaf

    2018-05-01

    Idiopathic laryngotracheal stenosis is a rare but well-described indication for subglottic tracheal resection. Initially described by Pearson in 1975, the 1-stage subglottic tracheal resection with reconstruction of the airway ensures preservation of the recurrent laryngeal nerves while resulting in an effective and durable repair of the stenosis. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Mitral stenosis in 15 dogs

    International Nuclear Information System (INIS)

    Lehmkuhl, L.B.; Ware, W.A.; Bonagura, J.D.

    1994-01-01

    Mitral stenosis was diagnosed in 15 young to middle-aged dogs. There were 5 Newfoundlands and 4 bull terriers affected, suggesting a breed predisposition for this disorder. Clinical signs included cough, dyspnea, exercise intolerance, and syncope. Soft left apical diastolic murmurs were heard only in 4 dogs, whereas 8 dogs had systolic murmurs characteristic of mitral regurgitation. Left atrial enlargement was the most prominent radiographic feature. Left-sided congestive heart failure was detected by radiographs in 11 dogs within 1 year of diagnosis. Electrocardiographic abnormalities varied among dogs and included atrial and ventricular enlargement, as well as atrial and ventricular arrhythmias. Abnormalities on M-mode and two-dimensional echocardiograms included abnormal diastolic motion of the mitral valve characterized by decreased leaflet separation, valve doming, concordant motion of the parietal mitral valve leaflet, and a decreased E-to-F slope. Increased mitral valve inflow velocities and prolonged pressure half-times were detected by Doppler echocardiography. Cardiac catheterization, performed in 8 dogs, documented a diastolic pressure gradient between the left atrial, pulmonary capillary wedge, or pulmonary artery diastolic pressures and the left ventricular diastolic pressure. Necropsy showed mitral stenosis caused by thickened, fused mitral valve leaflets in 5 dogs and a supramitral ring in another dog. The outcome in affected dogs was poor; 9 of 15 dogs were euthanatized or died by 2 1/2 years of age

  5. Renal Artery Stenosis (RAS) Case study

    International Nuclear Information System (INIS)

    Zaater, M.K.

    2012-01-01

    Renal Artery Stenosis (RAS), is one of the causes of secondary hypertension; there are many causes of renal artery stenosis, as atherosclerosis of the renal artery which account for 90% of cases of RAS; fibromuscular dysplasia accounts for 10% of RAS. Various causes of thrombophilia either due congenital causes or acquired causes and can lead to RAS. Our patient was presented by acute attack of epistaxis and hypertension. Angiography of the Renal Arteries,are showed no sign of renal artery stenosis. However, the right kidney showed upper pole infarction, and the left kidney showed evidence of functional lower pole renal artery stenosis, although there is no anatomical stenosis detected in angiography. Work up for the cause of thrombophilia did not help in the diagnosis, which may be due to an undiscovered cause of thrombophilia

  6. Hypochondroplasia with Foramen Magnum Stenosis: a Case Report

    Directory of Open Access Journals (Sweden)

    Nazik Aşılıoğlu

    2011-09-01

    Full Text Available Hypochondroplasia was first reported in the English literature by Beals (1969. The features are similar to those of achondroplasia but are less severe and are usually reported not to involve the skull. The foramen magnum and whole spinal canal are reduced in diameter in achondroplasia, but less so in hypochondroplasia. In this study, we present an unique case of a seven month old child with hypochondroplasia with symptomatic foramen magnum stenosis which required surgical decompression. This 7-month-old child with hypochondroplasia presented with hypotonia and severe respiratory disabilities, including apneic episodes requiring continuous positive airway pressure. Magnetic resonance imaging revealed marked foramen magnum stenosis. Foramen magnum decompression was performed. Postoperatively, steady motor improvement has been observed and the patient no longer requires ventilatory support. To the our knowledge, this is the first report of hypochondroplasia and symptomatic foramen magnum stenosis. In this case we wish to emphasize the necessity of the radiological imaging of foramen magnum and spinal cord for the patient who has respiratory distress and hypotonia with skeletal dysplasia.

  7. Permanences GAG-EPA

    CERN Document Server

    GAC-EPA

    2015-01-01

    Le GAC organise chaque mois des permanences avec entretiens individuels. La prochaine permanence se tiendra le : Mardi 5 mai de 13 h 30 à 16 h 00 Salle de réunion de l’Association du personnel Les permanences suivantes auront lieu les mardis 2 juin, 1er septembre, 6 octobre, 3 novembre et 1er décembre 2015. Les permanences du Groupement des Anciens sont ouvertes aux bénéficiaires de la Caisse de pensions (y compris les conjoints survivants) et à tous ceux qui approchent de la retraite. Nous invitons vivement ces derniers à s’associer à notre groupement en se procurant, auprès de l’Association du personnel, les documents nécessaires.

  8. Permanent quadrupole magnets

    International Nuclear Information System (INIS)

    Bush, E.D. Jr.

    1976-01-01

    A family of quadrupole magnets using a soft iron return yoke and circular cross-section permanent magnet poles were fabricated to investigate the feasibility for use in ion or electron beam focusing applications in accelerators and transport lines. Magnetic field measurements yielded promising results. In fixed-field applications, permanent magnets with sufficient gradients would be a low cost substitute for conventional electromagnets, eliminating the need for power supplies, associated wiring, and cooling. (author)

  9. Marxism as permanent revolution

    OpenAIRE

    van Ree, E.

    2013-01-01

    This article argues that the 'permanent revolution' represented the dominant element in Karl Marx and Friedrich Engels' political discourse, and that it tended to overrule considerations encapsulated in 'historical materialism'. In Marx and Engels's understanding, permanent revolution did not represent a historical shortcut under exceptional circumstances, but the course revolutions in the modern era would normally take. Marx and Engels traced back the pattern to the sixteenth century. It is ...

  10. How to perform combined cutting balloon and high pressure balloon valvuloplasty for dogs with subaortic stenosis.

    Science.gov (United States)

    Kleman, Mandi E; Estrada, Amara H; Maisenbacher, Herbert W; Prošek, Robert; Pogue, Brandon; Shih, Andre; Paolillo, Joseph A

    2012-01-01

    Subvalvular aortic stenosis (SAS) is one of the most common congenital cardiac malformations in dogs. Unfortunately, the long term success rate and survival data following either open heart surgery or catheter based intervention has been disappointing in dogs with severe subaortic stenosis. Medical therapy is currently the only standard recommended treatment option. A cutting balloon dilation catheter has been used successfully for resistant coronary artery and peripheral pulmonary arterial stenoses in humans. This catheter is unique in that it has the ability to cut, or score, the stenotic region prior to balloon dilatation of the stenosis. The use of cutting balloon valvuloplasty combined with high pressure valvuloplasty for dogs with severe subaortic stenosis has recently been reported to be a safe and feasible alternative therapeutic option. The following report describes this technique, outlines the materials required, and provides some 'tips' for successful percutaneous subaortic balloon valvuloplasty. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Macroscopic simulation of isotropic permanent magnets

    International Nuclear Information System (INIS)

    Bruckner, Florian; Abert, Claas; Vogler, Christoph; Heinrichs, Frank; Satz, Armin; Ausserlechner, Udo; Binder, Gernot; Koeck, Helmut; Suess, Dieter

    2016-01-01

    Accurate simulations of isotropic permanent magnets require to take the magnetization process into account and consider the anisotropic, nonlinear, and hysteretic material behaviour near the saturation configuration. An efficient method for the solution of the magnetostatic Maxwell equations including the description of isotropic permanent magnets is presented. The algorithm can easily be implemented on top of existing finite element methods and does not require a full characterization of the hysteresis of the magnetic material. Strayfield measurements of an isotropic permanent magnet and simulation results are in good agreement and highlight the importance of a proper description of the isotropic material. - Highlights: • Simulations of isotropic permanent magnets. • Accurate calculation of remanence magnetization and strayfield. • Comparison with strayfield measurements and anisotropic magnet simulations. • Efficient 3D FEM–BEM coupling for solution of Maxwell equations.

  12. Anesthesia for subglottic stenosis in pediatrics

    Directory of Open Access Journals (Sweden)

    Eid Essam

    2009-01-01

    Full Text Available Any site in the upper airway can get obstructed and cause noisy breathing as well as dyspnea. These include nasal causes such as choanal atresia or nasal stenosis; pharyngeal causes including lingual thyroid; laryngeal causes such as laryngomalacia; tracheobronchial causes such as tracheal stenosis; and subglottic stenosis. Lesions in the oropharynx may cause stertor, while lesions in the laryngotracheal tree will cause stridor. Subglottic stenosis is the third leading cause of congenital stridors in the neonate. Subglottic Stenosis presents challenges to the anesthesiologist. Therefore, It is imperative to perform a detailed history, physical examination, and characterization of the extent and severity of stenosis. Rigid endoscopy is essential for the preoperative planning of any of the surgical procedures that can be used for correction. Choice of operation is dependent on the surgeon′s comfort, postoperative capabilities, and severity of disease. For high-grade stenosis, single-stage laryngotracheal resection or cricotracheal resection are the best options. It has to be borne in mind that the goal of surgery is to allow for an adequate airway for normal activity without the need for tracheostomy. Anesthesia for airway surgery could be conducted safely with either sevofl uraneor propofol-based total intravenous anesthesia.

  13. Degenerative lumbosacral stenosis in dogs.

    Science.gov (United States)

    Meij, Björn P; Bergknut, Niklas

    2010-09-01

    Degenerative lumbosacral stenosis (DLSS) is the most common disorder of the caudal lumbar spine in dogs. This article reviews the management of this disorder and highlights the most important new findings of the last decade. Dogs with DLSS are typically neuro-orthopedic patients and can be presented with varying clinical signs, of which the most consistent is lumbosacral pain. Due to the availability of advanced imaging techniques such as computed tomography and magnetic resonance imaging that allow visualization of intervertebral disc degeneration, cauda equina compression, and nerve root entrapment, tailor-made treatments can be adopted for the individual patient. Current therapies include conservative treatment, decompressive surgery, and fixation-fusion of the L7-S1 junction. New insight into the biomechanics and pathobiology of DLSS and developments in minimally invasive surgical techniques will influence treatment options in the near future. Copyright 2010 Elsevier Inc. All rights reserved.

  14. Low-gradient aortic stenosis.

    Science.gov (United States)

    Clavel, Marie-Annick; Magne, Julien; Pibarot, Philippe

    2016-09-07

    An important proportion of patients with aortic stenosis (AS) have a 'low-gradient' AS, i.e. a small aortic valve area (AVA gradient (gradient discrepancy raises uncertainty about the actual stenosis severity and thus about the indication for aortic valve replacement (AVR) if the patient has symptoms and/or left ventricular (LV) systolic dysfunction. The most frequent cause of low-gradient (LG) AS is the presence of a low LV outflow state, which may occur with reduced left ventricular ejection fraction (LVEF), i.e. classical low-flow, low-gradient (LF-LG), or preserved LVEF, i.e. paradoxical LF-LG. Furthermore, a substantial proportion of patients with AS may have a normal-flow, low-gradient (NF-LG) AS: i.e. a small AVA-low-gradient combination but with a normal flow. One of the most important clinical challenges in these three categories of patients with LG AS (classical LF-LG, paradoxical LF-LG, and NF-LG) is to differentiate a true-severe AS that generally benefits from AVR vs. a pseudo-severe AS that should be managed conservatively. A low-dose dobutamine stress echocardiography may be used for this purpose in patients with classical LF-LG AS, whereas aortic valve calcium scoring by multi-detector computed tomography is the preferred modality in those with paradoxical LF-LG or NF-LG AS. Although patients with LF-LG severe AS have worse outcomes than those with high-gradient AS following AVR, they nonetheless display an important survival benefit with this intervention. Some studies suggest that transcatheter AVR may be superior to surgical AVR in patients with LF-LG AS. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  15. Carotid artery stenosis after neck radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Shimamura, Munehisa; Hashimoto, Yoichiro; Kasuya, Junji; Terasaki, Tadashi [Kumamoto City Hospital (Japan); Uchino, Makoto

    2000-02-01

    Carotid artery stenosis sometimes occurs after cervical radiotherapy. We report a 70-year-old woman with a history of radiotherapy for thyroid cancer at the age of 28 years. She had no signs and symptoms except the skin lesion at the irradiation site. Duplex ultrasonography revealed heterogeneous plaques showing 50% stenosis of bilateral common carotid arteries. Those lesions were observed within segment of irradiation, where atheromatous plaque usually seldom occurs. These indicated that the carotid stenosis was induced by radiotherapy. Although the efficacy of antiplatelet therapy for radiation-induced plaque is not clear, the plaques remained unchanged for 4 years in spite of aspirin administration. (author)

  16. Interventional treatment of transplanted renal artery stenosis

    International Nuclear Information System (INIS)

    Zhou Haihong; Chen Weiguo; Lu Wei; Chen Yong; Yan Xinmin; Zhou Jianyong; Li Yanhao

    2002-01-01

    Purpose: To evaluate the clinical application of percutaneous transluminal renal artery angioplasty (PTRA) in the treatment of transplanted renal artery stenosis. Methods: Nine patients with transplanted renal artery stenosis were treated by PTRA with balloon catheter through the f amoral artery. Metal stent was placed in 3 patients out of 9. Results: Technical success was obtained in all procedures. In 7 patients normal blood pressure was restored and serum creatinine remarkably decreased. But anti-hypertension drugs were still needed in rest 2 patients. Conclusion: PTRA and stent implantation are useful and valuable method in the treatment of transplanted renal artery stenosis

  17. Low permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.

    Science.gov (United States)

    Krackhardt, Florian; Kherad, Behrouz; Krisper, Maximilian; Pieske, Burkert; Laule, Michael; Tschöpe, Carsten

    2017-01-01

    Conduction disturbances requiring permanent pacemaker implantation following transcatheter aortic valve replacement (TAVR) are a common problem. Pacemaker implantation rates after TAVR appear to be higher compared to conventional aortic valve replacement. The aim of this study was to analyze whether a high annulus implantation conveys the benefit of a decreased rate of permanent pacemaker implantation while being safe and successful according to Valve Academic Research Consortium 2 (VARC2)-criteria. A total of 23 patients with symptomatic severe aortic valve stenosis, an aortic annulus of 19-27 mm and at high risk for surgery were treated with the Lotus valve. In all patients the valve was implanted in a high annulus position via femoral access. The primary device performance endpoint was VARC2-defined device success after 30 days and the primary safety endpoint was the need for permanent pacemaker implantation. The mean age was 73.23 ± 7.65 years, 46% were female, 38% were New York Heart Association class III/IV at baseline. Thirty-day follow-up data were available for all patients. The VARC2-defined device success rate after 30 days was 22/23 (96%). 2/21 (10%) patients required a newly implanted pacemaker due to 3rd degree atrioventricular block. 25% of the patients developed a new left bundle branch block after valvuloplasty or device implantation. 21 of the 23 patients (96%) had no other signs of conduction disturbances after 30 days. The approach of the modified implantation technique of Lotus TAVR device was safe and effective. The incidence of need for a permanent pacemaker following TAVR could be significantly reduced due to adopted implantation protocol.

  18. Image-Based 3-Dimensional Characterization of Laryngotracheal Stenosis in Children

    Directory of Open Access Journals (Sweden)

    Lee S. McDaniel PhD

    2018-01-01

    Full Text Available Objectives Describe a technique for the description and classification of laryngotracheal stenosis in children using 3-dimensional reconstructions of the airway from computed tomography (CT scans. Study Design Cross-sectional. Setting Academic tertiary care children’s hospital. Subjects and Methods Three-dimensional models of the subglottic airway lumen were created using CT scans from 54 children undergoing imaging for indications other than airway disease. The base lumen models were deformed in software to simulate subglottic airway segments with 0%, 25%, 50%, and 75% stenoses for each subject. Statistical analysis of the airway geometry was performed using metrics extracted from the lumen centerlines. The centerline analysis was used to develop a system for subglottic stenosis assessment and classification from patient-specific airway imaging. Results The scaled hydraulic diameter gradient metric derived from intersectional changes in the lumen can be used to accurately classify and quantitate subglottic stenosis in the airway based on CT scan imaging. Classification is most accurate in the clinically relevant 25% to 75% range of stenosis. Conclusions Laryngotracheal stenosis is a complex diagnosis requiring an understanding of the airway lumen configuration, anatomical distortions of the airway framework, and alterations of respiratory aerodynamics. Using image-based airway models, we have developed a metric that accurately captures subglottis patency. While not intended to replace endoscopic evaluation and existing staging systems for laryngotracheal stenosis, further development of these techniques will facilitate future studies of upper airway computational fluid dynamics and the clinical evaluation of airway disease.

  19. Management of bladder neck stenosis and urethral stricture and stenosis following treatment for prostate cancer.

    Science.gov (United States)

    Nicholson, Helen L; Al-Hakeem, Yasser; Maldonado, Javier J; Tse, Vincent

    2017-07-01

    The aim of this review is to examine all urethral strictures and stenoses subsequent to treatment for prostate cancer, including radical prostatectomy (RP), radiotherapy, high intensity focused ultrasound (HIFU) and cryotherapy. The overall majority respond to endoscopic treatment, including dilatation, direct visual internal urethrotomy (DVIU) or bladder neck incision (BNI). There are adjunct treatments to endoscopic management, including injections of corticosteroids and mitomycin C (MMC) and urethral stents, which remain controversial and are not currently mainstay of treatment. Recalcitrant strictures are most commonly managed with urethroplasty, while recalcitrant stenosis is relatively rare yet almost always associated with bothersome urinary incontinence, requiring bladder neck reconstruction and subsequent artificial urinary sphincter (AUS) implantation, or urinary diversion for the devastated outlet.

  20. Angioplasty in stenosis of the innominate artery

    International Nuclear Information System (INIS)

    Kobinia, G.S.; Bergmann, H. Jr.

    1983-01-01

    We describe a successful percutaneous transluminal dilatation (PTD) of an innominate artery stenosis in a 40-year-old patient with aortic arch syndrome. Five years earlier both a left central carotid artery occlusion and an innominate and left subclavian artery stenosis were treated by grafting from the aorta to the distal vessels. At recurrence of the neurological symptoms, reocclusion of the graft to the innominate artery and subtotal stenosis of the left carotid anastomosis were noted. The prevent the hazards of a reoperation, the innominate artery stenosis was dilated by means of PTD via the right brachial artery. Success of the procedure was demonstrated by Doppler sonography and angiography. It appears that PTD serves as an excellent method of treating stenoses of the aortic arch branches in aortic arch syndrome. (orig.)

  1. Mesenchymal stem cell therapy for laryngotracheal stenosis

    DEFF Research Database (Denmark)

    Jakobsen, Kathrine Kronberg; Grønhøj, Christian; Jensen, David H

    2017-01-01

    studies addressing the effect of MSC therapy on the airway. We assessed effect on inflammation, fibrosis, and MSC as a component in tissue engineering for treating defects in the airway. RESULTS: We identified eleven studies (n = 256 animals) from eight countries evaluating the effect of MSCs......BACKGROUND: Laryngotracheal stenosis (LTS) can be either congenital or acquired. Laryngeal stenosis is most often encountered after prolonged intubation. The mechanism for stenosis following intubation is believed to be hypertrophic scarring. Mesenchymal stem cells (MSCs) therapy has shown...... promising results in regenerative medicine. We aimed to systematically review the literature on MSC therapy for stenosis of the conductive airways. METHODS: PubMed, EMBASE, Google Scholar and the Cochrane Library were systematically searched from January 1980-January 2017 with the purpose of identifying all...

  2. Introduction to permanent magnets

    International Nuclear Information System (INIS)

    Zijlstra, H.

    1985-01-01

    Some general considerations concerning the application of permanent magnets are developed. The relevant magnet properties are discussed, with particular reference to Nd-Fe-B alloy. The author comes to the following conclusions; the air gap field B should be high, for high electrical efficiency; the magnet should face the air gap, for efficient use of the magnet material; the magnet material should therefore have a high remanence; and the new Nd-Fe-B magnet fits in nicely, having (potentially) the highest remanence ever reported in permanent magnets, combined with sufficient coercivity to sustain it

  3. The Kenny syndrome, a rare type of growth deficiency with tubular stenosis, transient hypoparathyroidism and anomalies of refraction.

    Science.gov (United States)

    Majewski, F; Rosendahl, W; Ranke, M; Nolte, K

    1981-03-01

    One family (3 cases) with the Kenny syndrome and a second family (3 cases) with features of Kenny syndrome but lacking medullary stenosis are reported. The main symptoms in both families are proportionate dwarfism, cortical thickening of tubular bones, variable anomalies of the calvaria, anemia, transient hypoparathyroidism and variable ocular anomalies. The latter include microphthalmia, and moderate-to-severe myopia or hyperopia. In the first family there was medullary stenosis of most tubular bones. In the second family two cases exhibited mild-to-moderate cortical thickening of tubular bones, but absent or mild medullary stenosis. Possible variability of the Kenny syndrome is discussed. Endocrine studies failed to demonstrate any permanent disturbance of parathormone or calcitonin metabolism, or GH deficiency. Pathogenesis remains unclear. Autosomal dominant inheritance seems to be likely.

  4. Subclavian steal syndrome without subclavian stenosis

    Directory of Open Access Journals (Sweden)

    Matt Cwinn, MD

    2017-09-01

    Full Text Available Subclavian steal syndrome (SSS has been well described in the setting of subclavian stenosis. We describe an unusual case of SSS caused by a high-flow arteriovenous dialysis fistula in the absence of subclavian stenosis, provide a review of the literature, and propose that arteriovenous fistula-induced SSS is an underdiagnosed cause of syncope in this population of patients.

  5. Internal auditory canal (IAC) stenosis: imaging Findings

    International Nuclear Information System (INIS)

    Ortiz Jimenez, Johanna; Roa, Jose Luis; Figuero A, Ramon E

    2011-01-01

    Objectives: To describe the computed tomography (CT) and magnetic resonance (MR) findings in a patient with a diagnosis of internal auditory canal (IAC) stenosis. To describe the embryological development of the IAC structures and the natural history of IAC stenosis. Methods: A 4 year old girl presents with sensorineural hearing loss and bilateral recurrent otitis media. The temporal bone CT shows diminished left IAC diameter (less than 2 mm), right IAC absence and normal inner ear structures. These findings are pathognomonic for left IAC stenosis. The MR findings include left IAC stenosis and IAC neural structures absence secondary to aplasia of the vestibulocochlear nerve on each IAC . Results: Hypoplasia/aplasia of the vestibulocochlear nerve in association with IAC stenosis is an important consideration in the differential diagnosis of sensorineural hearing loss, as it is a relative contraindication for cochlear implant placement. Conclusions: IAC stenosis and vestibulocochlear nerve hypoplasia/aplasia must be excluded as an etiology of sensorineural hearing loss. The diagnosis can be made by CT and MR.

  6. Internal auditory canal (IAC) stenosis: Imaging findings

    International Nuclear Information System (INIS)

    Ortiz J, Johanna; Roa, Jose L; Figueroa Ramon E

    2011-01-01

    Objectives: To describe the computed tomography (CT) and magnetic resonance (MR) findings in a patient with a diagnosis of internal auditory canal (IAC) stenosis. To describe the embryological development of the IAC structures and the natural history of IAC stenosis. Methods: A 4 year old girl presents with sensorineural hearing loss and bilateral recurrent otitis media. The temporal bone CT shows diminished left IAC diameter (less than 2 mm), right IAC absence and normal inner ear structures. These findings are pathognomonic for left IAC stenosis. The MR findings include left IAC stenosis and IAC neural structures absence secondary to aplasia of the vestibulocochlear nerve on each IAC. Results: Hypoplasia/aplasia of the vestibulocochlear nerve in association with IAC stenosis is an important consideration in the differential diagnosis of sensorineural hearing loss, as it is a relative contraindication for cochlear implant placement. Conclusions: IAC stenosis and vestibulocochlear nerve hypoplasia/aplasia must be excluded as an etiology of sensorineural hearing loss. The diagnosis can be made by CT and MR.

  7. Intracranial stenosis in cognitive impairment and dementia.

    Science.gov (United States)

    Hilal, Saima; Xu, Xin; Ikram, M Kamran; Vrooman, Henri; Venketasubramanian, Narayanaswamy; Chen, Christopher

    2017-06-01

    Intracranial stenosis is a common vascular lesion observed in Asian and other non-Caucasian stroke populations. However, its role in cognitive impairment and dementia has been under-studied. We, therefore, examined the association of intracranial stenosis with cognitive impairment, dementia and their subtypes in a memory clinic case-control study, where all subjects underwent detailed neuropsychological assessment and 3 T neuroimaging including three-dimensional time-of-flight magnetic resonance angiography. Intracranial stenosis was defined as ≥50% narrowing in any of the intracranial arteries. A total of 424 subjects were recruited of whom 97 were classified as no cognitive impairment, 107 as cognitive impairment no dementia, 70 vascular cognitive impairment no dementia, 121 Alzheimer's Disease, and 30 vascular dementia. Intracranial stenosis was associated with dementia (age/gender/education - adjusted odds ratios (OR): 4.73, 95% confidence interval (CI): 1.93-11.60) and vascular cognitive impairment no dementia (OR: 3.98, 95% CI: 1.59-9.93). These associations were independent of cardiovascular risk factors and MRI markers. However, the association with Alzheimer's Disease and vascular dementia became attenuated in the presence of white matter hyperintensities. Intracranial stenosis is associated with vascular cognitive impairment no dementia independent of MRI markers. In Alzheimer's Disease and vascular dementia, this association is mediated by cerebrovascular disease. Future studies focusing on perfusion and functional markers are needed to determine the pathophysiological mechanism(s) linking intracranial stenosis and cognition so as to identify treatment strategies.

  8. Object permanence in lemurs.

    Science.gov (United States)

    Deppe, Anja M; Wright, Patricia C; Szelistowski, William A

    2009-03-01

    Object permanence, the ability to mentally represent objects that have disappeared from view, should be advantageous to animals in their interaction with the natural world. The objective of this study was to examine whether lemurs possess object permanence. Thirteen adult subjects representing four species of diurnal lemur (Eulemur fulvus rufus, Eulemur mongoz, Lemur catta and Hapalemur griseus) were presented with seven standard Piagetian visible and invisible object displacement tests, plus one single visible test where the subject had to wait predetermined times before allowed to search, and two invisible tests where each hiding place was made visually unique. In all visible tests lemurs were able to find an object that had been in clear view before being hidden. However, when lemurs were not allowed to search for up to 25-s, performance declined with increasing time-delay. Subjects did not outperform chance on any invisible displacements regardless of whether hiding places were visually uniform or unique, therefore the upper limit of object permanence observed was Stage 5b. Lemur species in this study eat stationary foods and are not subject to stalking predators, thus Stage 5 object permanence is probably sufficient to solve most problems encountered in the wild.

  9. Citrullinemia type I and hypertrophic pyloric stenosis in a 1-month old male infant

    Directory of Open Access Journals (Sweden)

    Yoona Rhee

    2013-01-01

    Full Text Available Citrullinemia type I (CTLN1 is an inherited urea cycle disorder, now included in most newborn screening panels in the US and Europe. Due to argininosuccinate synthetase deficiency, CTLN1 can lead to recurrent hyperammonemic crisis that may result in permanent neurologic sequelae. Vomiting in patients with urea cycle disorders may either be the result or cause of acute hyperammonemia, particularly if due to an illness that leads to catabolism. Therefore, age-appropriate common etiologies of vomiting must be considered when evaluat- ing these patients. We present a 1-month old male infant with CTLN1 who had a 1-week history of vomiting and was discovered to have hypertrophic pyloric stenosis. This is the first documented case of an infant with CTLN1 who was later diagnosed with hypertrophic pyloric stenosis, and only the second case of concomitant disease.

  10. Ascites due to anastomotic stenosis after liver transplantation using the piggyback technique: Treatment with endovascular prosthesis

    International Nuclear Information System (INIS)

    Bilbao, Jose Ignacio; Herrero, Jose Ignacio; Martinez-Cuesta, Antonio; Quiroga, Jorge; Pueyo, Jesus Ciro; Vivas, Isabel; Delgado, Carlos; Pardo, Fernando

    2000-01-01

    Liver transplantation preserving the retrohepatic interior vena cava, the so-called piggyback technique, is becoming more frequently used because it avoids caval cross-clamping during the anhepatic phase of surgery. However, hepatic venous outflow blockade causing ascites seems to be less infrequent after piggyback than with cavo-caval anastomosis. We report a 62-year-old patient who underwent liver transplantation using the piggyback technique and developed a stenosis in the anastomosis between the hepatic veins and the inferior vena cava leading to severe postoperative ascites. Ascites was unresponsive to diuretic therapy and was associated with renal function impairment. Since the etiology of the stenosis was mechanical (torsion), percutaneous transluminal angioplasty was unsuccessful. Finally, an autoexpandable prosthesis was placed across the anastomosis resulting in rapid and permanent (3 years of follow-up) resolution of ascites.

  11. Retrospective analysis of co-occurrence of congenital aortic stenosis and pulmonary artery stenosis in dogs.

    Science.gov (United States)

    Kander, M; Pasławska, U; Staszczyk, M; Cepiel, A; Pasławski, R; Mazur, G; Noszczyk-Nowak, A

    2015-01-01

    The study has focused on the retrospective analysis of cases of coexisting congenital aortic stenosis (AS) and pulmonary artery stenosis (PS) in dogs. The research included 5463 dogs which were referred for cardiological examination (including clinical examination, ECG and echocardiography) between 2004 and 2014. Aortic stenosis and PS stenosis were detected in 31 dogs. This complex defect was the most commonly diagnosed in Boxers - 7 dogs, other breeds were represented by: 4 cross-breed dogs, 2 Bichon Maltais, 3 Miniature Pinschers, 2 Bernese Mountain Dogs, 2 French Bulldogs, and individuals of following breeds: Bichon Frise, Bull Terrier, Czech Wolfdog, German Shepherd, Hairless Chinese Crested Dog, Miniature Schnauzer, Pug, Rottweiler, Samoyed, West Highland White Terrier and Yorkshire Terrier. In all the dogs, the murmurs could be heard, graded from 2 to 5 (on a scale of 1-6). Besides, in 9 cases other congenital defects were diagnosed: patent ductus arteriosus, mitral valve dysplasia, pulmonary or aortic valve regurgitation, tricuspid valve dysplasia, ventricular or atrial septal defect. The majority of the dogs suffered from pulmonary valvular stenosis (1 dog had supravalvular pulmonary artery stenosis) and subvalvular aortic stenosis (2 dogs had valvular aortic stenosis). Conclusions and clinical relevance - co-occurrence of AS and PS is the most common complex congenital heart defect. Boxer breed was predisposed to this complex defect. It was found that coexisting AS and PS is more common in male dogs and the degree of PS and AS was mostly similar.

  12. [Permanent education in health: a review].

    Science.gov (United States)

    Miccas, Fernanda Luppino; Batista, Sylvia Helena Souza da Silva

    2014-02-01

    To undertake a meta-synthesis of the literature on the main concepts and practices related to permanent education in health. A bibliographical search was conducted for original articles in the PubMed, Web of Science, LILACS, IBECS and SciELO databases, using the following search terms: "public health professional education", "permanent education", "continuing education", "permanent education health". Of the 590 articles identified, after applying inclusion and exclusion criteria, 48 were selected for further analysis, grouped according to the criteria of key elements, and then underwent meta-synthesis. The 48 original publications were classified according to four thematic units of key elements: 1) concepts, 2) strategies and difficulties, 3) public policies and 4) educational institutions. Three main conceptions of permanent education in health were found: problem-focused and team work, directly related to continuing education and education that takes place throughout life. The main strategies for executing permanent education in health are discussion, maintaining an open space for permanent education , and permanent education clusters. The most limiting factor is mainly related to directly or indirect management. Another highlight is the requirement for implementation and maintenance of public policies, and the availability of financial and human resources. The educational institutions need to combine education and service aiming to form critical-reflexive graduates. The coordination between health and education is based as much on the actions of health services as on management and educational institutions. Thus, it becomes a challenge to implement the teaching-learning processes that are supported by critical-reflexive actions. It is necessary to carry out proposals for permanent education in health involving the participation of health professionals, teachers and educational institutions. To undertake a meta-synthesis of the literature on the main concepts and

  13. The Question of Decalage Between Object Permanence and Person Permanence

    Science.gov (United States)

    And Others; Jackson, Elaine

    1978-01-01

    Presents a study of decalage between object permanence and person permanence. Decalage was influenced by environmental as well as stimulus factors with infants tested between 6- and 81/4-months/of-age. (BD)

  14. Quantitative coronary CT angiography: absolute lumen sizing rather than %stenosis predicts hemodynamically relevant stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Plank, Fabian [Innsbruck Medical University, Department of Radiology, Innsbruck (Austria); Innsbruck Medical University, Department of Internal Medicine III - Cardiology, Innsbruck (Austria); Burghard, Philipp; Mayr, Agnes; Klauser, Andrea; Feuchtner, Gudrun [Innsbruck Medical University, Department of Radiology, Innsbruck (Austria); Friedrich, Guy; Dichtl, Wolfgang [Innsbruck Medical University, Department of Internal Medicine III - Cardiology, Innsbruck (Austria); Wolf, Florian [Vienna Medical University, Department of Cardiovascular and Interventional Radiology, Vienna (Austria)

    2016-11-15

    To identify the most accurate quantitative coronary stenosis parameter by CTA for prediction of functional significant coronary stenosis resulting in coronary revascularization. 160 consecutive patients were prospectively examined with CTA. Proximal coronary stenosis was quantified by minimal lumen area (MLA) and minimal lumen diameter (MLD), %area and %diameter stenosis. Lesion length (LL) was measured. The reference standard was invasive coronary angiography (ICA) (>70 % stenosis, FFR <0.8). 210 coronary segments were included (59 % positive). MLA of ≤1.8 mm{sup 2} was identified as the optimal cut-off (c = 0.97, p < 0.001; 95 % CI 0.94-0.99) (sensitivity 90.9 %, specificity 89.3 %) for prediction of functional-relevant stenosis (for MLA >2.1 mm{sup 2} sensitivity was 100 %). The optimal cut-off for MLD was 1.2 mm (c = 0.92; p < 0.001; 95 % CI 0.88-95) (sensitivity 90.9, specificity 85.2) while %area and %diameter stenosis were less accurate (c = 0.89; 95 % CI 0.84-93, c = 0.87; 95 % CI 0.82-92, respectively, with thresholds at 73 % and 61 % stenosis). Accuracy for LL was c = 0.74 (95 % CI 0.67-81), and for LL/MLA and LL/MLD ratio c = 0.90 and c = 0.84. MLA ≤1.8 mm{sup 2} and MLD ≤1.2 mm are the most accurate cut-offs for prediction of haemodynamically significant stenosis by ICA, with a higher accuracy than relative % stenosis. (orig.)

  15. First-line tracheal resection and primary anastomosis for postintubation tracheal stenosis.

    Science.gov (United States)

    Elsayed, H; Mostafa, A M; Soliman, S; Shoukry, T; El-Nori, A A; El-Bawab, H Y

    2016-07-01

    Introduction Tracheal stenosis following intubation is the most common indication for tracheal resection and reconstruction. Endoscopic dilation is almost always associated with recurrence. This study investigated first-line surgical resection and anastomosis performed in fit patients presenting with postintubation tracheal stenosis. Methods Between February 2011 and November 2014, a prospective study was performed involving patients who underwent first-line tracheal resection and primary anastomosis after presenting with postintubation tracheal stenosis. Results A total of 30 patients (20 male) were operated on. The median age was 23.5 years (range: 13-77 years). Seventeen patients (56.7%) had had previous endoscopic tracheal dilation, four (13.3%) had had tracheal stents inserted prior to surgery and one (3.3%) had undergone previous tracheal resection. Nineteen patients (63.3%) had had a tracheostomy. Eight patients (26.7%) had had no previous tracheal interventions. The median time of intubation in those developing tracheal stenosis was 20.5 days (range: 0-45 days). The median length of hospital stay was 10.5 days (range: 7-21 days). The success rate for anastomoses was 96.7% (29/30). One patient needed a permanent tracheostomy. The in-hospital mortality rate was 3.3%: 1 patient died from a chest infection 21 days after surgery. There was no mortality or morbidity in the group undergoing first-line surgery for de novo tracheal lesions. Conclusions First-line tracheal resection with primary anastomosis is a safe option for the treatment of tracheal stenosis following intubation and obviates the need for repeated dilations. Endoscopic dilation should be reserved for those patients with significant co-morbidities or as a temporary measure in non-equipped centres.

  16. Variable Permanent Magnet Quadrupole

    International Nuclear Information System (INIS)

    Mihara, T.; Iwashita, Y.; Kyoto U.; Kumada, M.; NIRS, Chiba; Spencer, C.M.; SLAC

    2007-01-01

    A permanent magnet quadrupole (PMQ) is one of the candidates for the final focus lens in a linear collider. An over 120 T/m strong variable permanent magnet quadrupole is achieved by the introduction of saturated iron and a 'double ring structure'. A fabricated PMQ achieved 24 T integrated gradient with 20 mm bore diameter, 100 mm magnet diameter and 20 cm pole length. The strength of the PMQ is adjustable in 1.4 T steps, due to its 'double ring structure': the PMQ is split into two nested rings; the outer ring is sliced along the beam line into four parts and is rotated to change the strength. This paper describes the variable PMQ from fabrication to recent adjustments

  17. Advance and permanent public information

    International Nuclear Information System (INIS)

    d'Oleon, C.

    1990-01-01

    The accident at CHERNOBYL highlighted one of the major problems facing the nuclear industry at present and during the years to come: the need to provide information. There are two aspects to this requirement: information at a time of crisis issued when an accident such as that at CHERNOBYL takes place, but which has to be based on a procedure set up before the crisis, and advance and permanent information which prepares the ground for information at a time of crisis. The requirement for information is of particular importance in France, given the preponderance of nuclear energy in the electricity generating industry. The procedure covers the principles which were forcefully asserted by the French public authorities during the CHERNOBYL crisis, the resources strengthened or established at that time, and finally, the introduction of a policy of wider-ranging communication which is based on the idea that one can never compromise with safety

  18. Superconducting permanent magnets

    International Nuclear Information System (INIS)

    Wipf, S.L.; Laquer, H.L.

    1989-01-01

    The concept of superconducting permanent magnets with fields trapped in shells or cylinders of Type II superconductors is an old one. Unfortunately, the low values of 0.5 to 1T for the first flux jump field, which is independent of the actual current density, have frustrated its implementation with classical Type II superconductors. The fact that the flux jump fields for high temperature superconductors should be an order of magnitude larger at liquid nitrogen temperatures allows us to reconsider these options. Analysis of the hysteresis patterns, based on the critical state model, shows that, if the dimensions are chosen so that the sample is penetrated at a field B/sub p/, which is equal to or just less than the first flux jump field, B/sub fj/, a temporarily applied field of 2B/sub fj/ will trap 0.5 B/sub fj/. Thus for a 90 K superconductor with a B/sub fj/ of 6T, a permanent field of 3 T should be trapped, with an energy product of 1.8 MJ/m/sup 3/ (225 MG . Oe). This is five times as large as for the best permanent magnet materials. The authors discuss means to verify the analysis and the limitations imposed by the low critical current densities in presently available high temperature superconductors

  19. Molecular and cellular mechanisms of aortic stenosis.

    Science.gov (United States)

    Yetkin, Ertan; Waltenberger, Johannes

    2009-06-12

    Calcific aortic stenosis is the most common cause of aortic valve replacement in developed countries, and this condition increases in prevalence with advancing age. The fibrotic thickening and calcification are common eventual endpoint in both non-rheumatic calcific and rheumatic aortic stenoses. New observations in human aortic valves support the hypothesis that degenerative valvular aortic stenosis is the result of active bone formation in the aortic valve, which may be mediated through a process of osteoblast-like differentiation in these tissues. Additionally histopathologic evidence suggests that early lesions in aortic valves are not just a disease process secondary to aging, but an active cellular process that follows the classical "response to injury hypothesis" similar to the situation in atherosclerosis. Although there are similarities with the risk factor and as well as with the process of atherogenesis, not all the patients with coronary artery disease or atherosclerosis have calcific aortic stenosis. This review mainly focuses on the potential vascular and molecular mechanisms involved in the pathogenesis of aortic valve stenosis. Namely extracellular matrix remodeling, angiogenesis, inflammation, and eventually osteoblast-like differentiation resulting in bone formation have been shown to play a role in the pathogenesis of calcific aortic stenosis. Several mediators related to underlying mechanisms, including growth factors especially transforming growth factor-beta1 and vascular endothelial growth factors, angiogenesis, cathepsin enzymes, adhesion molecules, bone regulatory proteins and matrix metalloproteinases have been demonstrated, however the target to be attacked is not defined yet.

  20. Lawful Permanent Residents - Annual Report

    Data.gov (United States)

    Department of Homeland Security — A lawful permanent resident (LPR) or 'green card' recipient is defined by immigration law as a person who has been granted lawful permanent residence in the United...

  1. Stenosis of calcified carotid artery detected on Panoramic Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, So Yang; Oh, Won Mann; Yoon, Suk Ja; Yoon, Woong; Lee, Jae Seo; Kang, Byung Cheol [School of Dentistry, Chonnam National University, Seoul (Korea, Republic of); Palomo, Juan M. [Department of Orthodontics, School of Dental Medicine, Case Western Reserve University, Cleveland (United States)

    2009-09-15

    This study aimed to investigate the luminal stenosis of the internal carotid artery with calcification detected on panoramic radiographs. This study used fifty carotid arteries of 36 dental patients whose panoramic radiograph and computed tomography angiography (CTA) revealed the presence of carotid artery calcification. A neuroradiologist interpreted CTA to determine the degree of stenosis of the internal carotid arteries. The degree of stenosis was stratified in four stages; normal (no stenosis), mild stenosis (1-49%), moderate stenosis (50-69%) and severe stenosis (70-99%). Among the fifty carotid arteries with calcification detected on both panoramic radiography and CTA, 20 carotid arteries (40%) were normal, 29 carotid arteries (18%) had mild stenosis, 1 carotid artery (2%) had moderate stenosis, and there was none with severe stenosis. Sixty percent of the carotid arteries with calcification detected on both panoramic radiography and CTA had internal luminal stenosis, and two percent had moderate stenosis. When carotid atheroma is detected on panoramic radiograph, it is possible that the dental patient has luminal stenosis of the internal carotid artery.

  2. Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents.

    Science.gov (United States)

    Cohen, José E; Gomori, John Moshe; Moscovici, Samuel; Leker, Ronen R; Itshayek, Eyal

    2014-07-01

    We assessed the frequency and severity of changes in stent configuration and location after the treatment of intracranial aneurysms, and patterns of in-stent stenosis. We retrospectively reviewed data for consecutive aneurysm patients managed with endovascular implantation of flow-diverter stents (Silk Flow Diverter [Balt Extrusion, Montmorency, France] and Pipeline Embolization Device [ev3/Coviden, Minneapolis, MN, USA]) from October 2011 to July 2012. Routine 2, 6, 9-12, and 16-20 month follow-up angiograms were compared, with a focus on changes in stent configuration and location from immediately after deployment to angiographic follow-up, and the incidence and development of in-stent stenosis. Thirty-four patients with 42 aneurysms met inclusion criteria. The Silk device was implanted in 16 patients (47%, single device in 15), the Pipeline device in 18 (53%, single device in 16). On first follow-up angiography, in-stent stenosis was observed in 38% of Silk devices and 39% of Pipeline devices. In-stent stenosis was asymptomatic in 12 of 13 patients. One woman presented with transient ischemic attacks and required stent angioplasty due to end tapering and mild, diffuse in-stent stenosis. Configuration and location changes, including stent creeping and end tapering were seen in 2/16 patients (13%) with Silk devices, and 0/18 patients with Pipeline devices. We describe stent creeping and end tapering as unusual findings with the potential for delayed clinical complications. In-stent stenosis, with a unique behavior, is a frequent angiographic finding observed after flow-diverter stent implant. The stenosis is usually asymptomatic; however, close clinical and angiographic monitoring is mandatory for individualized management. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Oriental Medical Treatment of Lumbar Spinal Stenosis

    Directory of Open Access Journals (Sweden)

    Hae-Yeon Lee

    2003-12-01

    Full Text Available Lumbar spinal stenosis results from the progressive combined narrowing of the central spinal canal, the neurorecesses, and the neuroforaminal canals. In the absence of prior surgery, tumor, or infection, the spinal canal may become narrowed by bulging or protrusion of the intervertebral disc annulus, herniation of the nucleus pulposis posteriorly, thickening of the posterior longitudinal ligament, hypertrophy of the ligamentum flavum, epidural fat deposition, spondylosis of the intervertebral disc margins, or a combination of two or more of the above factors. Patients with spinal stenosis become symptomatic when pain, motor weakness, paresthesia, or other neurologic compromise causes distress. In one case, we administrated oriental medical treatment with acupuncture treatment and herb-medicine. Oriental medical treatment showed desirable effect on lumbar spinal stenosis.

  4. Epidural venous stasis in spinal stenosis

    International Nuclear Information System (INIS)

    Kaiser, M.C.; Capesius, P.; Poos, D.; Gratia, G.; Roilgen, A.; Sandt, G.

    1984-01-01

    Computed tomography permits reliable demonstration of the spinal canal and its contents. Measurements of the sagittal diameter of the bony canal do not take into consideration size, shape and state of intraspinal soft tissue structures, i.e. the thecal sac and its own contents, epidural fat and blood circulation pattern. Three particularly illustrative cases were selected in which obvious epidural venous engorgement was visualized in association with spinal stenosis. The authors think that epidural venous stasis occuring in segmental spinal stenosis is a CT sign of clinically significant narrowing of the neural canal. Accurate recognition of the type of lumbar stenosis together with epidural blood flow alterations permits a better understanding of the existing lesions. Thus, a more precise and specific surgical approach is possible. (orig.)

  5. The Role of Tracheal Stenting As an Alternative Treatment in Cicatricial and Non-Operable Tracheal Stenosis

    Directory of Open Access Journals (Sweden)

    Reza Bagheri

    2013-05-01

    Full Text Available Introduction: Tracheal stenosis is normally caused by trauma, infection, benign and malignant tumors, prolonged intubation or tracheostomy. The best treatment for tracheal stenosis is resection and anastomosis of trachea. Yet the major surgical complication of tracheal surgery is postoperative stenosis. The goal of this paper is to study the result of tracheal stenting as a replacement therapy for patients suffering from tracheal stenosis who are not good candidates for surgery. Materials and Methods: This study presents the results of stenting in patients with: Inoperable tumoral stenosis,Non-tumoral stenosis being complicated due to prior surgeries,Inability to undergo a major surgery.The study was performed between September 2002 and July 2011 and poly flex stents were used by means of rigid bronchoscopy. Results: A total of 25 patients received stents during this study. Among them 15 patients suffered from benign and 10 suffered from malignant tracheal stenosis. The patients were followed up for at most 12 months after the stenting operation. The mean age of the patients was 35 years. The most common cause of stenosis was prolonged intubation (75%. The most common indication for stenting was the history of multiple tracheal operations. The most common complication of stenting and cause of stent removal was formation of granulation tissue. 30% of patients with benign tracheal stenosis were cured and about 10% improved until they could stand a major operation. Ten patients in benign group and 2 patients in malignant group (20% needed T-Tube insertion after stent removal but other patientcure by stenting. Conclusions: In benign cases stenting is associated with recurrence of symptoms which requires other therapeutic techniqus, so the stenting may not be named as a final solution in benign cases. However, this technique is the only method with approved efficacy for malignant cases with indication.

  6. Supravalvular aortic stenosis with sudden cardiac death

    Directory of Open Access Journals (Sweden)

    Pradeep Vaideeswar

    2015-01-01

    Full Text Available Sudden cardiac death (SCD most commonly results from previously undiagnosed congenital, acquired, or hereditary cardiac diseases. Congenital aortic valvular, subvalvular, and supravalvular disease with left ventricular outflow tract obstruction is an important preventable cause of sudden death. This report documents sudden death presumably due to acute myocardial ischemia in a young male with an undiagnosed supravalvular aortic stenosis (SVAS due to a rare association of isolation of coronary sinuses of Valsalva. Congenital supravalvular pulmonary stenosis and mitral valvular dysplasia were also present.

  7. Asymptomatic internal carotid artery stenosis and cerebrovascular risk stratification

    DEFF Research Database (Denmark)

    Nicolaides, Andrew N; Kakkos, Stavros K; Kyriacou, Efthyvoulos

    2010-01-01

    The purpose of this study was to determine the cerebrovascular risk stratification potential of baseline degree of stenosis, clinical features, and ultrasonic plaque characteristics in patients with asymptomatic internal carotid artery (ICA) stenosis.......The purpose of this study was to determine the cerebrovascular risk stratification potential of baseline degree of stenosis, clinical features, and ultrasonic plaque characteristics in patients with asymptomatic internal carotid artery (ICA) stenosis....

  8. Balloon dilation of congenital supravalvular pulmonic stenosis in a dog

    OpenAIRE

    Treseder, Julia R.; Jung, SeungWoo

    2017-01-01

    Percutaneous balloon valvuloplasty is considered the standard of care for treatment of valvular pulmonic stenosis, a common congenital defect in dogs. Supravalvular pulmonic stenosis is a rare form of pulmonic stenosis in dogs and standard treatment has not been established. Although, there have been reports of successful treatment of supravalvular pulmonic stenosis with surgical and stenting techniques, there have been no reports of balloon dilation to treat dogs with this condition. Here, a...

  9. Management of benign dynamic "A-shape" tracheal stenosis: a retrospective study of 60 patients.

    Science.gov (United States)

    Plojoux, Jérôme; Laroumagne, Sophie; Vandemoortele, Thomas; Astoul, Philippe J; Thomas, Pascal A; Dutau, Hervé

    2015-02-01

    Benign tracheal stenosis complicates tracheal intubation or tracheostomy in 0.6% to 65% of cases. Surgical resection is the standard treatment. Endoscopic management is used for inoperable patients with 17% to 69% success. Dynamic "A-shape" tracheal stenosis (DATS) results in a dynamic stenosis with anterior fracture of tracheal cartilage and frequently associated posterior malacia. We report the results of our multidisciplinary management. Sixty patients with DATS were included. Management decision was made during initial bronchoscopy. When suitable, patients were referred to thoracic surgery for tracheal resection. Posterior localized tracheomalacia was treated with laser photocoagulation of the posterior tracheal wall. Tracheal stents were placed if the stenosis persisted after laser treatment. The choice of stent (straight silicone, hour-glass shaped silicone, T-tube, or fully-covered self-expandable metallic stent) was based on operator's judgment. After 12 to 18 months, stents were removed. If the stenosis persisted after stent removal, surgery was reconsidered. If surgery was not possible, a stent was replaced. In case of satisfactory result, a stent was replaced only after recurrence. Stable patients after treatment were considered as success, requirement of long-term tracheostomy or T tube as failure, and long-term stent as partial success. All patients developed DATS after tracheostomy. Thirty-three patients had posterior tracheomalacia. In 13 patients, mild stenosis required only endoscopic surveillance. Two patients were referred to thoracic surgery for tracheal resection surgery. Endoscopic management was the initial therapy in 45 patients (75%) and was considered successful in 23 patients (51%), partially successful in 10 (22%), and failed in 12 (27%). Five patients with successful outcomes required only laser therapy. Overall 70 stents were placed in 35 patients, with a migration rate of 31%. The DATS management was successful in 63%. Stent migration

  10. Severe ipsilateral carotid stenosis and middle cerebral artery disease in lacunar ischaemic stroke: innocent bystanders?

    Science.gov (United States)

    Mead, G E; Lewis, S C; Wardlaw, J M; Dennis, M S; Warlow, C P

    2002-03-01

    Lacunar infarcts are thought to be mostly due to intracranial small vessel disease. Therefore, when a stroke patient with a relevant lacunar infarct does have severe ipsilateral internal carotid artery (ICA) or middle cerebral artery (MCA) disease, it is unclear whether the arterial disease is causative or coincidental. If causative, we would expect ICA/MCA disease to be more severe on the symptomatic side than on the asymptomatic side. Therefore, our aim was to compare the severity of ipsilateral with contralateral ICA and MCA disease in patients with lacunar ischaemic stroke. We studied 259 inpatients and outpatients with a recent lacunar ischaemic stroke and no other prior stroke. We used carotid Duplex ultrasound and transcranial Doppler (TCD) ultrasound to identify ICA and MCA disease, and compared our results with previously published data. In our study, there was no difference between the severity of ipsilateral and contralateral ICA stenosis within individuals (median difference 0%, Wilcoxon paired data p=0.24, comparing severity of ipsilateral and contralateral stenosis). The overall prevalence of severe ipsilateral stenosis was 5%, and the prevalence of severe contralateral stenosis was 4% (OR 1.6, 95% CI 0.6, 4.8). There was no difference in the prevalence of ipsilateral and contralateral MCA disease. A systematic review of the other available studies strengthened this conclusion. Carotid stenosis in patients with a lacunar ischaemic stroke may be coincidental. Further studies are required to elucidate the causes of lacunar stroke, and to evaluate the role of carotid endarterectomy.

  11. Studies on diagnosis and treatment of renal artery stenosis

    NARCIS (Netherlands)

    P. Krijnen (Pieta)

    2004-01-01

    textabstractThis thesis describes studies on ~onosis and treatment of renal artery stenosis in patients with drug-resistant hypertension. In Chapter 1, the clinical problem of renal artery stenosis is discussed. Renal artery stenosis, a narrowing of the renal artery, is a potential cause of

  12. IDIOPATHIC LARYN GEAL STENOSIS - A VERY RARE CASE

    OpenAIRE

    Sudip Kumar; Ruma; Rajesh; Arvind Kumar; Subhendu

    2014-01-01

    A 35 year old lady presented in the Out Patient Department with cough , dyspnea and gradual hoarseness for last 5 years. After proper history taking and thorough clinical examination , diagnosis of Laryngeal Stenosis was made. Subsequently by excluding important causes of Laryngeal Stenosis like trauma , chronic infection , tuberculosis and other granulomatous diseases , the diagnosis of Idiopathic Laryngeal Stenosis was established KEYWORDS ...

  13. The history of permanent magnet materials

    International Nuclear Information System (INIS)

    Livingston, J.D.

    1990-01-01

    Permanent-magnet materials play a large and growing, but largely unseen, role in today's technology. Many common devices in the home and elsewhere, including appliances, computers and printers, contain permanent-magnet motors and actuators. The growth of applications for permanent magnets results in large part from the improvements in magnetic properties, which allow the engineer to design smaller, lighter and more efficient devices. The properties of the greatest technological interest are remanence, coercivity and maximum energy product. All are non-equilibrium and high structure-sensitive. Coercivity is particularly sensitive to microstructure, while remanence is sensitive to texture (crystallographic alignment). The energy product depends on both coercivity and remanence. The more than one hundredfold increase in the available energy product in this century, and the corresponding amount of magnet required for a specific application, are shown

  14. CHALLENGES OF PERMANENT TEACHER TRAINING

    Directory of Open Access Journals (Sweden)

    María Manuela Valles-Ornelas

    2015-07-01

    Full Text Available The new challenges for teachers and managers require to assume permanent formation as a tool for responding effectively and efficiently to them, different perspective to strengthen from the initial teacher education programs. The research was done in a primary school in the state of Chihuahua. The method used was research action, the question was: How can we encourage the lifelong learning and training of the staff of this school, with the purpose to assist them in these processes to improve the service that the school provides to students. The school group is the center of the process, the cooperative and collaborative work accompanied by educational leadership and persuasive provide better results, and all accompanied by the professional selfinvitation.

  15. Nursing care of patients receiving interventional therapy for hepatic artery stenosis after liver transplantation

    International Nuclear Information System (INIS)

    Wei Lin; Liu Shiguang

    2009-01-01

    Objective: To discuss the perioperative nursing care of patients who is going to receive interventional therapy for hepatic artery stenosis after liver transplantation and to provide useful reference for reducing surgery-related complication and for improving the prognosis of patients. Methods: Based on the patient's condition and operative requirement,we provided effective nursing care for 20 patients who were admitted to receive the interventional therapy for hepatic artery stenosis after liver transplantation. The nursing care included preoperative preparation,postoperative nursing and medical guidance at the time of discharge. Results: Interventional therapy was successfully performed in all 20 cases, and no hemorrhagic tendency or acute thrombosis occurred. Marked symptomatic improvement was obtained in all patients. Conclusion: The interventional therapy is an effective treatment for hepatic artery stenosis after liver transplantation. Intensive perioperative nursing care can well prevent the occurrence of surgery-related complications and can surely improve the therapeutic results. (authors)

  16. New permanent magnets

    Science.gov (United States)

    Müller, K.-H.; Krabbes, G.; Fink, J.; Gruß, S.; Kirchner, A.; Fuchs, G.; Schultz, L.

    2001-05-01

    Permanent magnets play an important role and are widely spread in daily-life applications. Due to their very low costs, large availability of the row materials and their high chemical stability, hard ferrites are still dominant in the permanent magnet market although their relatively poor magnetic properties are a distinct disadvantage. Today's high-performance magnets are mostly made from Nd 2Fe 14B. The aim of research is to combine the large spontaneous magnetization of 3d metals with strong anisotropy fields known from rare-earth transition-metal compounds and, at the same time, to maintain a high value of the Curie temperature. However, the number of iron-rich rare-earth intermetallics is very limited and, consequently, not much success can be noted in this field for the last 10 years. One alternative concept is to use magnetic fields trapped in type II superconductors where much higher fields can be achieved compared to conventional rare-earth magnets. Very recently, we obtained a trapped field as high as 14.4 T in a melt-textured YBCO bulk sample of a few centimeters in diameter. This is the highest value ever achieved in a bulk superconductor. The trapped field of a superconductor is not governed by the Laplace equation and, therefore, levitation works without any additional (active) stabilization. The disadvantage of these magnets is their low working temperature (of liquid nitrogen and below).

  17. Cryogenic Permanent Magnet Undulators

    International Nuclear Information System (INIS)

    Chavanne, J.; Lebec, G.; Penel, C.; Revol, F.; Kitegi, C.

    2010-01-01

    For an in-vacuum undulator operated at small gaps the permanent magnet material needs to be highly resistant to possible electron beam exposure. At room temperature, one generally uses Sm 2 Co 17 or high coercivity NdFeB magnets at the expense of a limited field performance. In a cryogenic permanent magnet undulator (CPMU), at a temperature of around 150 K, any NdFeB grade reveals a coercivity large enough to be radiation resistant. In particular, very high remanence NdFeB material can be used to build undulators with enhanced field and X-ray brilliance at high photon energy provided that the pre-baking of the undulator above 100 deg. C can be eliminated. The ESRF has developed a full scale 2 m long CPMU with a period of 18 mm. This prototype has been in operation on the ID6 test beamline since January 2008. A significant effort was put into the characterization of NdFeB material at low temperature, the development of dedicated magnetic measurement systems and cooling methods. The measured heat budget with beam is found to be larger than expected without compromising the smooth operation of the device. Leading on from this first experience, new CPMUs are currently being considered for the upgrade of the ESRF.

  18. Sensorless V/f Control of Permanent Magnet Synchronous Motors

    OpenAIRE

    Montesinos-Miracle, Daniel; Perera, P. D. Chandana; Galceran-Arellano, Samuel; Blaabjerg, Frede

    2010-01-01

    V/f control strategy for permanent magnet synchronous motors can be useful for HVAC applications, where not high performance is required. Permanent magnet synchronous motors have efficiency advantages over the induction motor. But open loop V/f control is not stable in the whole frequency range. As demonstrated, the V/f control strategy becomes

  19. Congenital Hyperterophic Pyloric Stenosis of Infants | Mbanaso ...

    African Journals Online (AJOL)

    We present a 7-week-old male infant with congenital hyperterophic pyloric stenosis. The essence of this case report is to show that this condition could be mistaken for failure to thrive, protein caloric malnutrition, or ignorance on the part of the mother on how to feed the first born child. All these were suggested in our patient, ...

  20. Severe aortic valve stenosis and nosebleed

    NARCIS (Netherlands)

    Schoedel, Johannes; Obergfell, Achim; Maass, Alexander H.; Schodel, Johannes

    2007-01-01

    Aortic valve stenosis is known to be associated with loss of high molecular von Willebrand multimers. This can lead to gastrointestinal bleeding in patients with gastrointestinal angiodysplasia, the Heyde syndrome. Here we present a case of anaemia and severe epistaxis associated with acquired von

  1. Management of congenital esophageal stenosis associated with ...

    African Journals Online (AJOL)

    Aim The aim of this work was to study the incidence, management of congenital esophageal stenosis (CES) associated with esophageal atresia (EA) and tracheoesophageal fistula (TEF), and its impact on esophageal stricture (ES) after primary repair. Patients and methods From January 2006 to December 2014, ...

  2. Duplex ultrasound for identifying renal artery stenosis

    DEFF Research Database (Denmark)

    Zachrisson, Karin; Herlitz, Hans; Lönn, Lars

    2017-01-01

    Background Renal artery duplex ultrasound (RADUS) is an established method for diagnosis of renal artery stenosis (RAS), but there is no consensus regarding optimal RADUS criteria. Purpose To define optimal cutoff values for RADUS parameters when screening for RAS using intra-arterial trans...

  3. Temporary placement of metallic stent could lead to long-term benefits for benign tracheobronchial stenosis.

    Science.gov (United States)

    Zhou, Guo-Wu; Huang, Hai-Dong; Sun, Qin-Ying; Xiong, Ye; Li, Qiang; Dong, Yu-Chao; Zhang, Wei

    2015-12-01

    The permanent placement of metallic stent for benign tracheobronchial stenosis (BTS) was controversial. This study was conducted to evaluate the long-term outcomes of temporary placement of metallic stent for BTS. The BTS patients who received temporary placement of retrievable self-expanded metallic stents were included between 2008 and 2011. Pre-stenting and follow-up respiratory status was analyzed. And symptom recurrence-free survival (SRFS) was assessed. A total of 49 stents were successfully temporarily placed in 40 consecutive BTS patients whose etiologies included endobronchial tuberculosis (EBTB) (n=22), post-tracheostomy stenosis (n=10), post-intubation stenosis (n=6) and post radiotherapy stricture (n=2). All stents were removed integrally after a median 18 days' stenting period, without major complications. During the median 27 months follow-up period after stent removal, a total of 22 patients were free of recurrence. And the overall 3-year SRFS rate was 52.0%. According to the etiology, the 3-year SRFS rates were 59.1% and 42.9% in the patients with EBTB and non-EBTB, respectively. Compared with pre-stenting, the follow-up internal diameter of stricture, Hugh-Jones scale, 6-minute walk test (6MWT) and percentage of forced expiratory volume in one second (FEV1%) were significantly improved. Multivariate analysis suggested that granulation tissue growth and tracheobronchial malacia might be independent factors of poor prognosis. Temporary placement of retrievable metallic stent may be an alternative treatment for BTS patients.

  4. Stenosis differentially affects subendocardial and subepicardial arterioles in vivo.

    Science.gov (United States)

    Merkus, D; Vergroesen, I; Hiramatsu, O; Tachibana, H; Nakamoto, H; Toyota, E; Goto, M; Ogasawara, Y; Spaan, J A; Kajiya, F

    2001-04-01

    The presence of a coronary stenosis results primarily in subendocardial ischemia. Apart from the decrease in coronary perfusion pressure, a stenosis also decreases coronary flow pulsations. Applying a coronary perfusion system, we compared the autoregulatory response of subendocardial (n = 10) and subepicardial (n = 12) arterioles (production with N(G)-monomethyl-L-arginine abrogated the effect of the stenosis on flow. We conclude that the decrease in pressure caused by a stenosis in vivo results in a larger decrease in diameter of the subendocardial arterioles than in the subepicardial arterioles, and furthermore stenosis selectively decreases the dilatory response of subendocardial arterioles. These two findings expand our understanding of subendocardial vulnerability to ischemia.

  5. Assessment of extracranial ICA stenosis with color ultrasound and CEMRA

    International Nuclear Information System (INIS)

    Zhao Wenyuan; Liu Jianmin; Xu Yi; Hong Bo; Huang Qinghai; Zhang Long; Zhou Xiaoping

    2003-01-01

    Objective: To evaluate the color ultrasound and CEMRA in assessment of extracranial ICA stenosis. Methods: The preoperation assessment of color ultrasound and CEMRA were reviewed in 93 cases who underwent interventional treatment for severe extracranial ICA stenosis. Results: Ultrasonic examination could reveal the nature and severity of the stenosis, while CEMRA could explore full length of carotid artery and find tandem stenosis. They both possessed a trend for overestimating the stenosis and could hardly show plaque ulceration. Conclusions: Up to the moment, neither color ultrasound nor CEMRA can substitute DSA. A combination of DSA, color ultrasound, and CEMRA could provide details of the stenotic ICA drawing an appropriate operation plan

  6. Balloon dilation of congenital supravalvular pulmonic stenosis in a dog.

    Science.gov (United States)

    Treseder, Julia R; Jung, SeungWoo

    2017-03-30

    Percutaneous balloon valvuloplasty is considered the standard of care for treatment of valvular pulmonic stenosis, a common congenital defect in dogs. Supravalvular pulmonic stenosis is a rare form of pulmonic stenosis in dogs and standard treatment has not been established. Although, there have been reports of successful treatment of supravalvular pulmonic stenosis with surgical and stenting techniques, there have been no reports of balloon dilation to treat dogs with this condition. Here, a case of supravalvular pulmonic stenosis diagnosed echocardiographically and angiographically in which a significant reduction in pressure gradient was achieved with balloon dilation alone is presented.

  7. Aortic stenosis: From diagnosis to optimal treatment

    Directory of Open Access Journals (Sweden)

    Tavčiovski Dragan

    2008-01-01

    Full Text Available Aortic stenosis is the most frequent valvular heart disease. Aortic sclerosis is the first characteristic lesion of the cusps, which is considered today as the process similar to atherosclerosis. Progression of the disease is an active process leading to forming of bone matrix and heavily calcified stiff cusps by inflammatory cells and osteopontin. It is a chronic, progressive disease which can remain asymptomatic for a long time even in the presence of severe aortic stenosis. Proper physical examination remains an essential diagnostic tool in aortic stenosis. Recognition of characteristic systolic murmur draws attention and guides further diagnosis in the right direction. Doppler echocardiography is an ideal tool to confirm diagnosis. It is well known that exercise tests help in stratification risk of asymptomatic aortic stenosis. Serial measurements of brain natriuretic peptide during a follow-up period may help to identify the optimal time for surgery. Heart catheterization is mostly restricted to preoperative evaluation of coronary arteries rather than to evaluation of the valve lesion itself. Currently, there is no ideal medical treatment for slowing down the disease progression. The first results about the effect of ACE inhibitors and statins in aortic sclerosis and stenosis are encouraging, but there is still not enough evidence. Onset symptoms based on current ACC/AHA/ESC recommendations are I class indication for aortic valve replacement. Aortic valve can be replaced with a biological or prosthetic valve. There is a possibility of percutaneous aortic valve implantation and transapical operation for patients that are contraindicated for standard cardiac surgery.

  8. Perineal colostomy: an alternative to avoid permanent abdominal colostomy: operative technique, results and reflection.

    Science.gov (United States)

    da Silva, Alcino Lázaro; Hayck, Johnny; Deoti, Beatriz

    2014-01-01

    The most common injury to indicate definitive stoma is rectal cancer. Despite advances in surgical treatment, the abdominoperineal resection is still the most effective operation in radical treatment of malignancies of the distal rectum invading the sphincter and anal canal. Even with all the effort that surgeons have to preserve anal sphincters, abdominoperineal amputation is still indicated, and a definitive abdominal colostomy is necessary. This surgery requires patients to live with a definitive abdominal colostomy, which is a condition that modify body image, is not without morbidity and has great impact on the quality of life. To evaluate the technique of abdominoperineal amputation with perineal colostomy with irrigation as an alternative to permanent abdominal colostomy. Retrospective analysis of medical records of 55 patients underwent abdominoperineal resection of the rectum with perineal colostomy in the period 1989-2010. The mean age was 58 years, 40 % men and 60 % women. In 94.5% of patients the indication for surgery was for cancer of the rectum. In some patients were made three valves, other two valves and in the remaining no valve at all. Complications were: mucosal prolapse, necrosis of the lowered segment and stenosis. The abdominoperineal amputation with perineal colostomy is a good therapeutic option in the armamentarium of the surgical treatment of rectal cancer.

  9. Endovascular therapy of carotid stenosis with self-expandable stent

    International Nuclear Information System (INIS)

    Liu Jianmin; Huang Qinghai; Hong Bo; Xu Yi; Zhao Wenyuan; Zhang Yongwei; Zhang Long; Zhou Xiaoping

    2002-01-01

    Objective: To summarize the experience of endovascular treatment of carotid stenosis with expandable stents. Methods: Fifty-two patients with carotid stenosis who experienced repeated transient ischemic attacks or cerebral infarction were admitted to our hospital. The stenosis was pre-expanded with undetachable balloon, and self-expandable stents were implanted across the stenosis. A balloon catheter was used to further expand stents in 29 patients. Results: The stent was accurately implanted, and total disappearance of stenosis was obtained in 34 patients, the degree of stenosis reduced more than 90% in 16 patients, and more than 70% in 2 patients. The patients recovered well and no complications related to the procedure occurred. None experienced TIA or infarction postoperatively in 52 cases and follow-up imaging in 19 patients (6 - 12 months) demonstrated no restenosis. Conclusion: Endovascular stenting may be a safe and valid choice for the treatment of extracranial carotid stenosis

  10. Lumbar foraminal stenosis, the hidden stenosis including at L5/S1.

    Science.gov (United States)

    Orita, Sumihisa; Inage, Kazuhide; Eguchi, Yawara; Kubota, Go; Aoki, Yasuchika; Nakamura, Junichi; Matsuura, Yusuke; Furuya, Takeo; Koda, Masao; Ohtori, Seiji

    2016-10-01

    In patients with lower back and leg pain, lumbar foraminal stenosis (LFS) is one of the most important pathologies, especially for predominant radicular symptoms. LFS pathology can develop as a result of progressing spinal degeneration and is characterized by exacerbation with foraminal narrowing caused by lumbar extension (Kemp's sign). However, there is a lack of critical clinical findings for LFS pathology. Therefore, patients with robust and persistent leg pain, which is exacerbated by lumbar extension, should be suspected of LFS. Radiological diagnosis is performed using multiple radiological modalities, such as magnetic resonance imaging, including plain examination and novel protocols such as diffusion tensor imaging, as well as dynamic X-ray, and computed tomography. Electrophysiological testing can also aid diagnosis. Treatment options include both conservative and surgical approaches. Conservative treatment includes medication, rehabilitation, and spinal nerve block. Surgery should be considered when the pathology is refractory to conservative treatment and requires direct decompression of the exiting nerve root, including the dorsal root ganglia. In cases with decreased intervertebral height and/or instability, fusion surgery should also be considered. Recent advancements in minimally invasive lumbar lateral interbody fusion procedures enable effective and less invasive foraminal enlargement compared with traditional fusion surgeries such as transforaminal lumbar interbody fusion. The lumbosacral junction can cause L5 radiculopathy with greater incidence than other lumbar levels as a result of anatomical and epidemiological factors, which should be better addressed when treating clinical lower back pain.

  11. Use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats: six cases (2005-2007).

    Science.gov (United States)

    Berent, Allyson C; Weisse, Chick; Todd, Kimberly; Rondeau, Mark P; Reiter, Alexander M

    2008-11-01

    To determine outcome associated with use of a balloon-expandable metallic stent for treatment of nasopharyngeal stenosis in dogs and cats. Retrospective case series. 3 dogs and 3 cats. All 6 animals had severe inspiratory stertor at initial examination. Two animals had no orifice present at the stenosis. Nasopharyngeal stenosis was diagnosed and stent size determined by use of computed tomography. A percutaneous transluminal angioplasty balloon premounted with a balloon-expandable metallic stent was placed over a guidewire, advanced through the stenotic lesion under fluoroscopic and rhinoscopic guidance, and dilated to restore patency. All animals had immediate resolution of clinical signs after stent placement. The procedure took a median of 38 minutes (range, 22 to 70 minutes). One animal with a stenosis located far caudally needed the tip of the stent resected because of hairball entrapment and exaggerated swallowing. Both animals without an orifice in the stenosis had tissue in-growth requiring a covered stent. All animals were reexamined 6 to 12 weeks after treatment via rhinoscopy, radiography, computed tomography, or a combination of techniques. All animals lacked signs of discomfort; 5 of 6 were breathing normally 12 to 28 months after the procedure. Transnasal balloon-expandable metallic stent placement may represent a rapid, safe, noninvasive, and effective treatment in animals with nasopharyngeal stenosis. If the stenosis is extremely caudal in the nasopharynx, serial balloon dilatation might be considered prior to stent placement. A covered stent should be considered initially if the stenosis is completely closed.

  12. Tracheal stenosis: our experience at a tertiary care centre in India with special regard to cause and management.

    Science.gov (United States)

    Nair, Satish; Mohan, Sharad; Mandal, Ghanashyam; Nilakantan, Ajith

    2014-01-01

    Tracheal stenosis (TS), a challenging problem, is a known complication of prolonged intubation and tracheostomy. The management involves a multidisciplinary approach with multiple complex procedures. In this study we discuss our experience with severe TS with regards to patient characteristics, cause and management. A retrospective analysis of 20 patients of severe TS treated at a tertiary care centre was evaluated. Inclusion criteria were all patients with severe TS who required surgical intervention. Exclusion criteria were patients with associated laryngeal stenosis and TS due to cancer. Demographic data was recorded and findings relating to aetiology, characteristics of stenosis and the various aspects of therapeutic procedures performed are discussed with review of literature. Descriptive analysis of data were performed SPSS 18. Results of the 20 patients, 17 patients (85 %) developed TS post tracheostomy, or post intubation and subsequent tracheostomy. 13 Patients (65 %) had true stenosis of which 7 patients (35 %) had simple web or circumferential fibrosis and 6 patients (30 %) had complex stenosis. Seven patients (35 %) had granulations causing severe TS which were mostly suprastomal (5 patients), stomal (5 patients) and combined stomal and suprastomal (3 patients). The average length of stenosis was 3.57 cm (0.5-8 cm). Montgomery t tube insertion was a common procedure in 18 patients (90 %) pre or post intervention. Each patient underwent an average of 3.4 procedures during their course of treatment which included rigid bronchoscopy and mechanical debulking, Nd YAG laser, KTP laser, balloon dilatation and use of stents. Among the 7 patients with granulations 100 % successful decanulation was noted with endoscopic management whereas in 13 patients with true stenosis, 10 patients (76.9 %) required open surgical management (8 tracheal resection and anastomosis and 2 tracheoplasty) with 80 % successful decanulation, 2 patients (15.4 %) were treated

  13. Preoperative MRI findings predict two-year postoperative clinical outcome in lumbar spinal stenosis.

    Directory of Open Access Journals (Sweden)

    Pekka Kuittinen

    Full Text Available To study the predictive value of preoperative magnetic resonance imaging (MRI findings for the two-year postoperative clinical outcome in lumbar spinal stenosis (LSS.84 patients (mean age 63±11 years, male 43% with symptoms severe enough to indicate LSS surgery were included in this prospective observational single-center study. Preoperative MRI of the lumbar spine was performed with a 1.5-T unit. The imaging protocol conformed to the requirements of the American College of Radiology for the performance of MRI of the adult spine. Visual and quantitative assessment of MRI was performed by one experienced neuroradiologist. At the two-year postoperative follow-up, functional ability was assessed with the Oswestry Disability Index (ODI 0-100% and treadmill test (0-1000 m, pain symptoms with the overall Visual Analogue Scale (VAS 0-100 mm, and specific low back pain (LBP and specific leg pain (LP separately with a numeric rating scale from 0-10 (NRS-11. Satisfaction with the surgical outcome was also assessed.Preoperative severe central stenosis predicted postoperatively lower LP, LBP, and VAS when compared in patients with moderate central stenosis (p<0.05. Moreover, severe stenosis predicted higher postoperative satisfaction (p = 0.029. Preoperative scoliosis predicted an impaired outcome in the ODI (p = 0.031 and lowered the walking distance in the treadmill test (p = 0.001. The preoperative finding of only one stenotic level in visual assessment predicted less postoperative LBP when compared with patients having 2 or more stenotic levels (p = 0.026. No significant differences were detected between quantitative measurements and the patient outcome.Routine preoperative lumbar spine MRI can predict the patient outcome in a two-year follow up in patients with LSS surgery. Severe central stenosis and one-level central stenosis are predictors of good outcome. Preoperative finding of scoliosis may indicate worse functional ability.

  14. Serial office-based steroid injections for treatment of idiopathic subglottic stenosis.

    Science.gov (United States)

    Hoffman, Matthew R; Coughlin, Adam R; Dailey, Seth H

    2017-11-01

    Current treatment options for idiopathic subglottic stenosis include endoscopic interventions, resection, and tracheotomy. Recently, serial office-based steroid injections were proposed as an alternative that may stabilize or induce regression of airway stenosis without the need for repeated operations. Procedure completion rate, pain, complications, effect on stenosis, time since the last operation, and limitations have not been described. Retrospective case series. Retrospective series of 19 patients undergoing serial office-based steroid injection for idiopathic subglottic stenosis. Outcome measures included completion rate, procedure-related pain scores, complications, percentage of airway stenosis, and time since the last operative intervention. Procedure completion rate was 98.8%. Average pain score during the procedure was 2.3 ± 1.7 on a 10-point scale. There were no immediate complications. One patient underwent awake tracheotomy 8 days after her second injection and was later decannulated. Average stenosis decreased from 35% ± 15% to 25% ± 15% (n = 16; P = .086) over the first of three injections and 40% ± 15% to 25% ± 10% to 20% ± 10% (n = 8; P = .002) for those patients completing two sets of three injections. Fourteen of 17 patients undergoing at least three injections have not returned to the operating room since the first injection. Office-based steroid injection represents a promising new treatment pathway for a disease that requires long-term management, offering a purely pharmacologic approach to a disorder that has traditionally been approached from a mechanical perspective. It is safe, well tolerated, and effective. Furthermore, it may help patients and physicians avoid repeated trips to the operating room and the associated risks. 4. Laryngoscope, 127:2475-2481, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  15. [Management of malignant and benign airway stenosis by stent implantation].

    Science.gov (United States)

    Gyulai, Márton; Slavei, Krisztina; Pénzes, István; Strausz, János

    2006-11-12

    In the last few decades the different bronchoscopic procedures have gained an important role in the treatment of airway stenosis, and the number of implanted airway stents has also greatly increased. Between 1998 and 2004 the authors implanted altogether 108 airway prosthesis in 90 patients at the Institute of Pulmonology of Pest County. 58% of the patients were males, 42% females, the average age was 57.5 years, the average follow-up time was 7 months. On the basis of different etiology the patients were separated into two main groups. In 57% the airway stenosis was caused by malignant illnesses, in these cases stents can be used only with palliative purpose. However, in case of benign lesions they can offer a long-term solution and require an adequate follow-up of the patients. The authors' main aim was to get an overall picture of the interventions they had done by processing the data, with the help of the measurable characteristics that make possible to follow the airways' permeability and its changes. Analysing the results of the respiratory function and blood gas examinations they didn't find a significant difference inspite of the subjective improvement.

  16. Single-incision laparoscopic surgery for pyloric stenosis.

    Science.gov (United States)

    Kozlov, Yury; Novogilov, Vladimir; Podkamenev, Alexey; Rasputin, Andrey; Weber, Irina; Solovjev, Alexey; Yurkov, Pavel

    2012-04-01

    Laparoscopy is the most common procedure for correction of congenital pyloric stenosis. The standard laparoscopic approach is based on the three-port technique. In contrast to the standard laparoscopic technique, the single-incision laparoscopic surgery (SILS) requires only one incision. We report on our experience with this surgical approach. Between September 2009 and August 2010 a total of 24 children underwent a laparoscopic pyloromyotomy, 12 in SILS technique. The single incision was carried through the center of the umbilicus. The working instruments were introduced in a two-dimensional direction into the peritoneal cavity via the same umbilical incision. The two groups were compared for patients' demographics, operative report and early postoperative outcomes. All SILS procedures were performed successfully with no conversion rate. There were no differences in the preoperative parameters between the two groups regarding age before surgery and body weight at operation. Operative time and time of full enteral intake was similar to comparable procedures with usage of a standard laparoscopic approach. There were no operative or postoperative complications. The early experience described in this study confirms that SILS can be applied for treatment of pyloric stenosis with outcomes similar to the standard laparoscopic surgery.

  17. [The Object Permanence Fallacy.] Commentary.

    Science.gov (United States)

    Bradley, Ben S.

    1996-01-01

    Suggests that Greenberg's challenge to the centrality of object permanence in developmental thinking reveals that developmentalists' theories about childhood speak about their own self-images. Notes that developmentalists have been guilty of not only the object permanence fallacy but also the genetic fallacy, or the mistaken belief that describing…

  18. Early rectal stenosis following stapled rectal mucosectomy for hemorrhoids

    Directory of Open Access Journals (Sweden)

    Schuster Anja

    2004-05-01

    Full Text Available Abstract Background Within the last years, stapled rectal mucosectomy (SRM has become a widely accepted procedure for second and third degree hemorrhoids. One of the delayed complications is a stenosis of the lower rectum. In order to evaluate the specific problem of rectal stenosis following SRM we reviewed our data with special respect to potential predictive factors or stenotic events. Methods A retrospective analysis of 419 consecutive patients, which underwent SRM from December 1998 to August 2003 was performed. Only patients with at least one follow-up check were evaluated, thus the analysis includes 289 patients with a mean follow-up of 281 days (±18 days. For statistic analysis the groups with and without stenosis were evaluated using the Chi-Square Test, using the Kaplan-Meier statistic the actuarial incidence for rectal stenosis was plotted. Results Rectal stenosis was observed in 9 patients (3.1%, eight of these stenoses were detected within the first 100 days after surgery; the median time to stenosis was 95 days. Only one patient had a rectal stenosis after more than one year. 8 of the 9 patients had no obstructive symptoms, however the remaining patients complained of obstructive defecation and underwent surgery for transanal strictureplasty with electrocautery. A statistical analysis revealed that patients with stenosis had significantly more often prior treatment for hemorrhoids (p Conclusion Rectal stenosis is an uncommon event after SRM. Early stenosis will occur within the first three months after surgery. The majority of the stenoses are without clinical relevance. Only one of nine patients had to undergo surgery for a relevant stenosis. The predictive factor for stenosis in the patient-characteristics is previous interventions for hemorrhoids, severe postoperative pain might also predict rectal stenosis.

  19. Pulsatile spiral blood flow through arterial stenosis.

    Science.gov (United States)

    Linge, Fabian; Hye, Md Abdul; Paul, Manosh C

    2014-11-01

    Pulsatile spiral blood flow in a modelled three-dimensional arterial stenosis, with a 75% cross-sectional area reduction, is investigated by using numerical fluid dynamics. Two-equation k-ω model is used for the simulation of the transitional flow with Reynolds numbers 500 and 1000. It is found that the spiral component increases the static pressure in the vessel during the deceleration phase of the flow pulse. In addition, the spiral component reduces the turbulence intensity and wall shear stress found in the post-stenosis region of the vessel in the early stages of the flow pulse. Hence, the findings agree with the results of Stonebridge et al. (2004). In addition, the results of the effects of a spiral component on time-varying flow are presented and discussed along with the relevant pathological issues.

  20. Global Strain in Severe Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Dahl, Jordi S; Videbæk, Lars; Poulsen, Mikael K

    2012-01-01

    Score, history with ischemic heart disease and ejection fraction. CONCLUSIONS: -In patients with symptomatic severe aortic stenosis undergoing AVR reduced GLS provides important prognostic information beyond standard risk factors. Clinical Trial Registration-URL: http://www.clinicaltrial.gov. Unique identifier......BACKGROUND: -Global longitudinal systolic strain (GLS) is often reduced in aortic stenosis despite normal ejection fraction. The importance of reduced preoperative GLS on long-term outcome after aortic valve replacement (AVR) is unknown. METHODS AND RESULTS: -A total of 125 patients with severe...... and mortality. In a stepwise cox model with forward selection GLS was the sole independent predictor HR=1.13 (95% confidence interval 1.02-1.25), p=0.04. Comparing the overall log likelihood χ(2) of the predictive power of the multivariable model containing GLS was statistically superior to models based on Euro...

  1. Current management of symptomatic intracranial stenosis.

    Science.gov (United States)

    Taylor, Robert A; Weigele, John B; Kasner, Scott E

    2011-08-01

    Intracranial arterial stenosis (IAS) is the cause of about 10% of all ischemic strokes in the United States, but may account for about 40% of strokes in some populations. After a stroke or transient ischemic attack due to IAS, patients face a 12% annual risk of recurrent stroke on medical therapy, with most strokes occurring in the first year. Warfarin is no better than aspirin in preventing recurrent strokes but poses a higher risk of serious bleeding and death. Groups with the highest risk of recurrent stroke are those with high-grade (≥ 70%) stenosis, those with recent symptom onset, those with symptoms precipitated by hemodynamic maneuvers, and women. Endovascular treatment of IAS is a rapidly evolving therapeutic option. Antiplatelet agents are currently recommended as the primary treatment for symptomatic IAS, with endovascular therapy reserved for appropriate high-risk cases refractory to medical therapy.

  2. An Unusual Cause of Rectal Stenosis

    Directory of Open Access Journals (Sweden)

    Maja Gruber

    2016-08-01

    Full Text Available Solitary rectal ulcer syndrome (SRUS is a benign disease that is often misdiagnosed. It is characterized by a combination of symptoms, endoscopic findings and histology. Patients present with constipation, rectal bleeding, mucous discharge, pain and a sensation of incomplete defecation. There are many different manifestations of this disease, with or without rectal prolapse. We report an unusual presentation of SRUS as a circular stenosis in a middle-aged male.

  3. Infantile hypertrophic pyloric stenosis. Infantil hypertrofisk pylorusstenose

    Energy Technology Data Exchange (ETDEWEB)

    Breivik, K.; Soereide, J.A.; Bland, J. (Rogaland Central Hospital, Stavanger (Norway))

    1990-09-01

    During an eight-year period, 40 patients were operated consecutively for pyloric stenosis. The most common symptom was projectile vomiting, which occurred in 92.5% of the cases. On examination only three patients had a palpable hypertrophic pylorus. In 39 patients a preoperative X-ray examination with contrast was necessary to confirm the diagnosis. A pyleromyotomy was performed in all patients. The diagnosis routines and the results of the treatment are discussed. 16 refs., 2 figs., 3 tabs.

  4. Post intubation tracheal stenosis in children

    Directory of Open Access Journals (Sweden)

    Marco Caruselli

    2014-12-01

    Full Text Available Many authors have reported that tracheal stenosis is a complication that can follow tracheal intubation in both adults and children. The symptoms, when they do appear, can be confused with asthma, with subsequent treatment providing only mild and inconsistent relief. We report here the case of an 8 year old girl admitted to our hospital for whooping cough that was not responding to therapy.

  5. Diagnosis of supravalvar stenosis of aorta

    International Nuclear Information System (INIS)

    Shumskij, V.I.; Konstantinova, N.V.; Pokidkin, V.A.

    1989-01-01

    The authors analyzed the potentialities of combined radiodiagnosis of supravalvar stenosis (SS) and concomitant diseases of the heart and major vessels (Williams-Beuren syndrome) in 7 patients aged 7 mos. to 24 yrs. Polypositional chest and heart X-ray procedure, catheterization of the cardiac cavities, pulmonary artery and aorta, left ventriculography (6), right ventriculography (4) and angiopulmonography were used. The diagnostic potentialities of each method were defined

  6. Standards on the permanence of recording materials

    Science.gov (United States)

    Adelstein, Peter Z.

    1996-02-01

    The permanence of recording materials is dependent upon many factors, and these differ for photographic materials, magnetic tape and optical disks. Photographic permanence is affected by the (1) stability of the material, (2) the photographic processing and (3) the storage conditions. American National Standards on the material and the processing have been published for different types of film and standard test methods have been established for color film. The third feature of photographic permanence is the storage requirements and these have been established for photographic film, prints and plates. Standardization on the permanence of electronic recording materials is more complicated. As with photographic materials, stability is dependent upon (1) the material itself and (2) the storage environment. In addition, retention of the necessary (3) hardware and (4) software is also a prerequisite. American National Standards activity in these areas has been underway for the past six years. A test method for the material which determines the life expectancy of CD-ROMs has been standardized. The problems of determining the expected life of magnetic tape have been more formidable but the critical physical properties have been determined. A specification for the storage environment of magnetic tape has been finalized and one on the storage of optical disks is being worked on. Critical but unsolved problems are the obsolescence of both the hardware and the software necessary to read digital images.

  7. Percutaneous balloon dilation of pulmonary stenosis

    International Nuclear Information System (INIS)

    Hua Yangde; Huang Ming; Li Jinkang; Qian Jinqing; Chen Xiuyu; Yang Siyuan

    2003-01-01

    Objective: Review our experience of balloon dilation of valvular pulmonary stenosis in 32 cases. Methods: Totally 32 cases of pulmonary stenosis admitted from 1995-2001 with age of 1.5-13 yrs mean 6.8. Diagnosis was made by clinical manifestations, EKG, ECHO and angiocardiography. Results: Before dilation, the mean systolic pressure of right ventricle was (93.5 ± 28.5) mmHg, after the procedure it reduced to (42 ± 9.0) mmHg. The pressure gradient between right ventricle and pulmonary artery before dilation was (76 ± 30) mmHg and become (24.5 ± 8.5) mmHg after dilation. The gradient pressure after dilation was less than 25 mmHg in 90.6% cases. A case of Noonan syndrome showed no response to balloon dilation and died during valvulectomy from accompanying left ventricular cardiomyopathy. Conclusions: Balloon dilation of valvular pulmonary stenosis is effective and safe. The selection of proper diameter of pulmonary valvular rings and sized of the balloon are the major factors

  8. Neutron induced permanent damage in Josephson junctions

    International Nuclear Information System (INIS)

    Mueller, G.P.; Rosen, M.

    1982-01-01

    14 MeV neutron induced permanent changes in the critical current density of Josephson junctions due to displacement damage in the junction barrier are estimated using a worst case model and the binary collision simulation code MARLOWE. No likelihood of single event hard upsets is found in this model. It is estimated that a fluence of 10 18 -10 19 neutrons/cm 2 are required to change the critical current density by 5%

  9. Changes in the Flow-Volume Curve According to the Degree of Stenosis in Patients With Unilateral Main Bronchial Stenosis

    Science.gov (United States)

    Yoo, Jung-Geun; Yi, Chin A; Lee, Kyung Soo; Jeon, Kyeongman; Um, Sang-Won; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung

    2015-01-01

    Objectives The shape of the flow-volume (F-V) curve is known to change to showing a prominent plateau as stenosis progresses in patients with tracheal stenosis. However, no study has evaluated changes in the F-V curve according to the degree of bronchial stenosis in patients with unilateral main bronchial stenosis. Methods We performed an analysis of F-V curves in 29 patients with unilateral bronchial stenosis with the aid of a graphic digitizer between January 2005 and December 2011. Results The primary diseases causing unilateral main bronchial stenosis were endobronchial tuberculosis (86%), followed by benign bronchial tumor (10%), and carcinoid (3%). All unilateral main bronchial stenoses were classified into one of five grades (I, ≤25%; II, 26%-50%; III, 51%-75%; IV, 76%-90%; V, >90% to near-complete obstruction without ipsilateral lung collapse). A monophasic F-V curve was observed in patients with grade I stenosis and biphasic curves were observed for grade II-IV stenosis. Both monophasic (81%) and biphasic shapes (18%) were observed in grade V stenosis. After standardization of the biphasic shape of the F-V curve, the breakpoints of the biphasic curve moved in the direction of high volume (x-axis) and low flow (y-axis) according to the progression of stenosis. Conclusion In unilateral bronchial stenosis, a biphasic F-V curve appeared when bronchial stenosis was >25% and disappeared when obstruction was near complete. In addition, the breakpoint moved in the direction of high volume and low flow with the progression of stenosis. PMID:26045916

  10. Intracranial cerebral artery stenosis with associated coronary artery and extracranial carotid artery stenosis in Turkish patients

    Energy Technology Data Exchange (ETDEWEB)

    Alkan, Ozlem [Department of Radiology, Baskent University, Faculty of Medicine, Ankara (Turkey)], E-mail: yalinozlem@hotmail.com; Kizilkilic, Osman; Yildirim, Tulin [Department of Radiology, Baskent University, Faculty of Medicine, Ankara (Turkey); Atalay, Hakan [Department of Cardiovascular Surgery, Baskent University, Faculty of Medicine, Ankara (Turkey)

    2009-09-15

    Purpose: Although it has been demonstrated that there is a high prevalence of extracranial carotid artery stenosis (ECAS) in patients with severe coronary artery disease, intracranial cerebral artery stenosis (ICAS) is rarely mentioned. We evaluated the prevalence of ICAS in patients with ECAS having elective coronary artery bypass grafting (CABG) surgery to determine the relations between ICAS, ECAS and atherosclerotic risk factors. Methods: We retrospectively reviewed the digital subtraction angiography findings of 183 patients with ECAS {>=} 50% preparing for CABG surgery. The analyses focused on the intracranial or extracranial location and degree of the stenosis. The degree of extracranial stenoses were categorized as normal, <50%, 50-69%, 70-89%, and 90-99% stenosis and occluded. The degree of intracranial stenosis was classified as normal or {<=}25%, 25-49%, and {>=}50% stenosis and occluded. Traditional atherosclerotic risk factors were recorded. Results: ECAS < 70% in 42 patients and ECAS {>=} 70% in 141 patients. ICAS was found in 51 patients and ICAS {>=} 50% in 30 patients. Regarding risk factors, we found hypertension in 135 patients, diabetes mellitus in 91 patients, hyperlipidemia in 84 patients, and smoking in 81 patients. No risk factor was significant predictors of intracranial atherosclerosis. The severity of ICAS was not significantly associated with that of the ECAS. Conclusions: We found ICAS in 27.8% of the patients with ECAS > 50% on digital subtraction angiography preparing for CABG. Therefore a complete evaluation of the neck vessels with magnetic resonance or catheter angiography seems to be indicated as well as intracranial circulation for the risk assessment of CABG.

  11. Permanent isolation surface barrier development plan

    International Nuclear Information System (INIS)

    Wing, N.R.

    1994-01-01

    The exhumation and treatment of wastes may not always be the preferred alternative in the remediation of a waste site. In-place disposal alternatives, under certain circumstances, may be the most desirable alternatives to use in the protection of human health and the environment. The implementation of an in-place disposal alternative will likely require some type of protective covering that will provide long-term isolation of the wastes from the accessible environment. Even if the wastes are exhumed and treated, a long-term barrier may still be needed to adequately dispose of the treated wastes or any remaining waste residuals. Currently, no open-quotes provenclose quotes long-term barrier is available. The Hanford Site Permanent Isolation Surface Barrier Development Program (BDP) was organized to develop the technology needed to provide a long-term surface barrier capability for the Hanford Site. The permanent isolation barrier technology also could be used at other sites. Permanent isolation barriers use engineered layers of natural materials to create an integrated structure with redundant protective features. Drawings of conceptual permanent isolation surface barriers are shown. The natural construction materials (e.g., fine soil, sand, gravel, riprap, asphalt) have been selected to optimize barrier performance and longevity. The objective of current designs is to use natural materials to develop a maintenance-free permanent isolation surface barrier that isolates wastes for a minimum of 1,000 years by limiting water drainage to near-zero amounts; reducing the likelihood of plant, animal, and human intrusion; controlling the exhalation of noxious gases; and minimizing erosion-related problems

  12. Permanent isolation surface barrier development plan

    Energy Technology Data Exchange (ETDEWEB)

    Wing, N.R.

    1994-01-01

    The exhumation and treatment of wastes may not always be the preferred alternative in the remediation of a waste site. In-place disposal alternatives, under certain circumstances, may be the most desirable alternatives to use in the protection of human health and the environment. The implementation of an in-place disposal alternative will likely require some type of protective covering that will provide long-term isolation of the wastes from the accessible environment. Even if the wastes are exhumed and treated, a long-term barrier may still be needed to adequately dispose of the treated wastes or any remaining waste residuals. Currently, no {open_quotes}proven{close_quotes} long-term barrier is available. The Hanford Site Permanent Isolation Surface Barrier Development Program (BDP) was organized to develop the technology needed to provide a long-term surface barrier capability for the Hanford Site. The permanent isolation barrier technology also could be used at other sites. Permanent isolation barriers use engineered layers of natural materials to create an integrated structure with redundant protective features. Drawings of conceptual permanent isolation surface barriers are shown. The natural construction materials (e.g., fine soil, sand, gravel, riprap, asphalt) have been selected to optimize barrier performance and longevity. The objective of current designs is to use natural materials to develop a maintenance-free permanent isolation surface barrier that isolates wastes for a minimum of 1,000 years by limiting water drainage to near-zero amounts; reducing the likelihood of plant, animal, and human intrusion; controlling the exhalation of noxious gases; and minimizing erosion-related problems.

  13. Leadership in a (permanent) crisis.

    Science.gov (United States)

    Heifetz, Ronald; Grashow, Alexander; Linsky, Marty

    2009-01-01

    The current economic crisis is not just another rough spell. Today's mix of urgency, high stakes, and uncertainty will continue even after the recession ends. The immediate crisis--which we will get through with policy makers' expert technical adjustments--sets the stage for a sustained, or even permanent, crisis, a relentless series of challenges no one has encountered before. Instead of hunkering down and relying on their familiar expertise to deal with the sustained crisis, people in positions of authority--whether they are CEOs or managers heading up a company initiative--must practice what the authors call adaptive leadership. They must, of course, tackle the underlying causes of the crisis, but they must also simultaneously make the changes that will allow their organizations to thrive in turbulent environments. Adaptive leadership is an improvisational and experimental art, requiring some new practices. Like Julie Gilbert, who overcame internal resistance to reorient Best Buy toward female purchasers, adaptive leaders get things done to meet today's challenges and then modify those things to thrive in tomorrow's world. They also embrace disequilibrium, using turbulence as an opportunity to build crucial new capacities, as Paul Levy did to rescue Beth Israel Deaconess Medical Center from a profound financial crisis. Finally, adaptive leaders, such as Egon Zehnder, the founder of an executive search firm, draw out the leadership skills that reside deep in the organization, recognizing the interdependence of all employees and mobilizing everyone to generate solutions.

  14. Surgical treatment of congenital mitral stenosis: medium-term results

    Directory of Open Access Journals (Sweden)

    Atik Fernando A.

    2003-01-01

    Full Text Available OBJECTIVE: For a cohort of patients with congenital mitral stenosis (CMS, to determine: patient outcomes, predictors of valve repairability and predictors of durability of valve repair. METHODS: From 1989 and 2002, 23 patients underwent surgical treatment of CMS, excluding those with common atrioventricular canal, and univentricular forms. The median age at operation was 15.5 months (range 2-204, and the median body weight was 11 Kg (range 4.5-51.6. Seventeen patients (73.9% had associated anomalies, including Shone's complex in nine (39.1% and pulmonary hypertension in 14 (60.9%. Mitral stenosis was severe in 14 patients (60.9% and moderate in the remaining (median trans-mitral gradient of 16 mmHg, range 8.5-32. Mitral valve repair was performed in 18 patients (78.3%, and valve replacement in five (21.7%. Repair techniques included papillary muscle splitting (n=10, excision of supravalvular ring (n=9 and commissurotomy (n=8. Twelve patients (52.2% required associated procedures. RESULTS: There were no early and late deaths at a mean follow-up of 58.5 ± 46.7 months (range 1-156. Mean hospital stay was 12.7 ± 8.2 days. There were no significant factors associated with unsuccessful valve repair. Actuarial freedom from reoperation at five years was 67.1% (CI 95%: 56.8% to 77.4%. The mitral valve repair group required reoperation in eight patients (44.4% (two early and six late, as opposed to one (20% in the replacement group. The presence of preoperative pulmonary hypertension was significantly related (p<0.005 to higher reoperation rates. All but two the followed patients are presently in functional class I and the echocardiography has shown less than 2+ mitral stenosis and/or regurgitation. CONCLUSION: Reoperations were the most important cause of morbidity at the medium-term follow-up of CMS. Preoperative pulmonary hypertension may predict the need for reoperation after mitral valve repair, which is the procedure of choice in CMS.

  15. Topology optimized permanent magnet systems

    Science.gov (United States)

    Bjørk, R.; Bahl, C. R. H.; Insinga, A. R.

    2017-09-01

    Topology optimization of permanent magnet systems consisting of permanent magnets, high permeability iron and air is presented. An implementation of topology optimization for magnetostatics is discussed and three examples are considered. The Halbach cylinder is topology optimized with iron and an increase of 15% in magnetic efficiency is shown. A topology optimized structure to concentrate a homogeneous field is shown to increase the magnitude of the field by 111%. Finally, a permanent magnet with alternating high and low field regions is topology optimized and a Λcool figure of merit of 0.472 is reached, which is an increase of 100% compared to a previous optimized design.

  16. Topology optimized permanent magnet systems

    DEFF Research Database (Denmark)

    Bjørk, Rasmus; Bahl, Christian; Insinga, Andrea Roberto

    2017-01-01

    Topology optimization of permanent magnet systems consisting of permanent magnets, high permeability iron and air is presented. An implementation of topology optimization for magnetostatics is discussed and three examples are considered. The Halbach cylinder is topology optimized with iron...... and an increase of 15% in magnetic efficiency is shown. A topology optimized structure to concentrate a homogeneous field is shown to increase the magnitude of the field by 111%. Finally, a permanent magnet with alternating high and low field regions is topology optimized and a ΛcoolΛcool figure of merit of 0...

  17. Periodic permanent magnet focused klystron

    Science.gov (United States)

    Ferguson, Patrick; Read, Michael; Ives, R Lawrence

    2015-04-21

    A periodic permanent magnet (PPM) klystron has beam transport structures and RF cavity structures, each of which has permanent magnets placed substantially equidistant from a beam tunnel formed about the central axis, and which are also outside the extent of a cooling chamber. The RF cavity sections also have permanent magnets which are placed substantially equidistant from the beam tunnel, but which include an RF cavity coupling to the beam tunnel for enhancement of RF carried by an electron beam in the beam tunnel.

  18. Subglottic stenosis in granulomatosis with polyangiitis (Wegener's granulomatosis): Report of 4 cases.

    Science.gov (United States)

    Horta-Baas, Gabriel; Hernández-Cabrera, María Fernanda; Catana, Rocío; Pérez-Cristóbal, Mario; Barile-Fabris, Leonor Adriana

    2016-01-01

    Subglottic stenosis (SGS) in granulomatosis with polyangiitis (GPA) may result from active disease or from chronic recurrent inflammation. The objective of the study was to describe the clinical features and treatment of patients with subglottic stenosis. We retrospectively reviewed the medical records of all patients with SGS due to GPA diagnosed at Rheumatology deparment between January 2000 and June 2015. We present 4 cases of SGS at our department during a period of 15 years. The interval between the presentation of the GPA and SGS varied between 2 and 144 months. The leading symptoms of SGS were dyspnoea on exertion and stridor. Three patients presented SGS without evidence of systemic activity. Two patients presented SGS grade i and received tracheal dilatation; two recurred and three needed a tracheostomy due to severe airway-limiting stenosis. SGS presents high morbidity. Even though subglottic dilatation provides symptomatic relief, recurrences may present. Severe airway-limiting stenosis often requires tracheostomy. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  19. The effect of medical treatments on stroke risk in asymptomatic carotid stenosis.

    Science.gov (United States)

    King, Alice; Shipley, Martin; Markus, Hugh

    2013-02-01

    Recent evidence suggests current best medical treatment may be sufficient to prevent stroke in patients with asymptomatic carotid stenosis. If this is the case, then it is important to determine risk reduction provided by treatments. Using Asymptomatic Carotid Emboli Study (ACES) prospective data, the effect of current treatment and risk factors on future stroke and transient ischemic attack risk were determined. Four-hundred seventy-seven patients with asymptomatic carotid stenosis were followed-up every 6 months for 2 years. Changes in risk factors and stroke prevention therapies were reviewed at each visit. Using time-dependent Cox regression, the relationship between current treatment over time was determined and presented as hazard ratios and 95% confidence intervals for risk of stroke, transient ischemic attack, and cardiovascular death end points. On multivariate analysis, antiplatelets (P=0.001) and lower mean blood pressure (P=0.002) were independent predictors of reduced risk of ipsilateral stroke and transient ischemic attack. Antiplatelets (Pstroke or cardiovascular death. Antiplatelet therapy and blood pressure control are the most important factors in reducing short-term stroke and cardiovascular risk in patients with asymptomatic carotid stenosis. More prospective data are required for medical treatments in asymptomatic carotid stenosis in particular for current statin usage.

  20. Evaluation of the efficacy and safety of endovascular management for transplant renal artery stenosis

    Directory of Open Access Journals (Sweden)

    Leonardo G.M. Valle

    Full Text Available OBJECTIVES: To evaluate the safety and efficacy of endovascular intervention with angioplasty and stent placement in patients with transplant renal artery stenosis. METHODS: All patients diagnosed with transplant renal artery stenosis and graft dysfunction or resistant systemic hypertension who underwent endovascular treatment with stenting from February 2011 to April 2016 were included in this study. The primary endpoint was clinical success, and the secondary endpoints were technical success, complication rate and stent patency. RESULTS: Twenty-four patients with transplant renal artery stenosis underwent endovascular treatment, and three of them required reinterventions, resulting in a total of 27 procedures. The clinical success rate was 100%. All graft dysfunction patients showed decreased serum creatinine levels and improved estimated glomerular filtration rates and creatinine levels. Patients with high blood pressure also showed improved control of systemic blood pressure and decreased use of antihypertensive drugs. The technical success rate of the procedure was 97%. Primary patency and assisted primary patency rates at one year were 90.5% and 100%, respectively. The mean follow-up time of patients was 794.04 days after angioplasty. CONCLUSION: Angioplasty with stent placement for the treatment of transplant renal artery stenosis is a safe and effective technique with good results in both the short and long term.

  1. Incidence and predictors of permanent pacemaker implantation following treatment with the repositionable Lotus™ transcatheter aortic valve.

    Science.gov (United States)

    Zaman, Sarah; McCormick, Liam; Gooley, Robert; Rashid, Hashrul; Ramkumar, Satish; Jackson, Damon; Hui, Samuel; Meredith, Ian T

    2017-07-01

    To determine the incidence and predictors of permanent pacemaker (PPM) requirement following transcatheter aortic valve replacement (TAVR) with the mechanically expanded Lotus TM Valve System (Boston Scientific). Pacemaker implantation is the most common complication following TAVR. Predictors of pacing following TAVR with the Lotus valve have not been systematically assessed. Consecutive patients with severe aortic stenosis who underwent Lotus valve implantation were prospectively recruited at a single-centre. Patients with a pre-existing PPM were excluded. Baseline ECG, echocardiographic and multiple detector computed tomography as well as procedural telemetry and depth of implantation were independently analyzed in a blinded manner. The primary endpoint was 30-day incidence of pacemaker requirement (PPM implantation or death while pacing-dependent). Multivariate analysis was performed to identify independent predictors of the primary endpoint. A total of 104 consecutive patients underwent TAVR with the Lotus valve with 9/104 (9%) with a pre-existing PPM excluded. New or worsened procedural LBBB occurred in 78%. Thirty-day incidence of the primary pacing endpoint was 28%. The most common indication for PPM implantation was complete heart block (CHB) (69%). Independent predictors of the primary endpoint included pre-existing RBBB (hazard ratio [HR] 2.8, 95% CI 1.1-7.0; P = 0.032) and depth of implantation below the noncoronary cusp (NCC) (HR 2.4, 95% CI 1.0-5.7; P = 0.045). Almost a third of Lotus valve recipients require pacemaker implantation within 30 days. The presence of pre-existing RBBB and the depth of prosthesis implantation below the NCC were significant pacing predictors. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. INTRACRANIAL STENOSIS IN PATIENTS WITH ACUTE CEREBROVASCULAR ACCIDENTS

    Directory of Open Access Journals (Sweden)

    Hossein Zarei

    2010-12-01

    Full Text Available Abstract    INTRODUCTION: This study was conducted to investigate pattern and risk factors associated with the location of atherosclerotic occlusive lesions in cerebral vessels. Previous studies of patients with stroke or transient ischemic attack (TIA suggest that extracranial atherosclerosis is more common in the white race. Noninvasive techniques such as duplex ultrasound, transcranial Doppler (TCD, and magnetic resonance angiography (MRA allow vascular assessment of a more representative proportion of the patients, compared to conventional angiography alone.    METHODS: We evaluated patients with cerebrovascular problems (stroke and/or TIA during a period of 6 months, using duplex ultrasonography, TCD and MRA to detect significant stenosis according to standard criteria.    RESULTS: Stenosis of extracranial and intracranial arteries was detected in 38% and 29% of cases, respectively. MCA was the most frequent involved intracranial artery (11% bilaterally and 5% unilaterally. Intracranial lesions tend to be multiple. There was no significant difference between men and women in terms of frequency and distribution of stenosis. No correlation was found between opium use and stenosis. The women had significantly more poor windows than men (P<0.05. The extracranial stenosis was significantly more frequent than intracranial stenosis (P<0.01.    CONCLUSION: The relations between hypertension and extracranial stenosis, and diabetes and MCA stenosis were statistically significant. TCD seemed to be a better technique for evaluating intracranial lesions in men than in women.      Keywords: Atherosclerosis, Stenosis, Carotid artery, Doppler Sonography.  

  3. The epidemiologic role of cervical spinal stenosis in quadriplegia

    International Nuclear Information System (INIS)

    Silverstein, G.S.; Kohn, M.I.; Peyster, R.G.; Teplick, J.G.

    1988-01-01

    Plain lateral films of 45 quadriplegic and 100 control patients were compared, with the spinal canal-vertebral body ration method used to assess sagittal canal size. Statistical analysis revealed that a ration below 0.86 indicated significant stenosis. Using this threshold, 73% of quadriplegics had preexisting stenosis at the level of injury, compared with 19% of controls. Stenosis was found to be a strong contributing factor in quadriplegia following burst fracture or subluxation and a prerequisite for cord injury without fracture or dislocation. Selective plain film screening for stenosis might be justified in an attempt to prevent catastrophic cord injuries by appropriate patient counseling

  4. Lawful Permanent Residents Fiscal Year 2014 Country

    Data.gov (United States)

    Department of Homeland Security — Lawful permanent residents (LPRs) are foreign nationals who have been granted the right to reside permanently in the United States. LPRs are also known as 'permanent...

  5. Lawful Permanent Residents Fiscal Year 2011 State

    Data.gov (United States)

    Department of Homeland Security — Lawful permanent residents (LPRs) are foreign nationals who have been granted the right to reside permanently in the United States. LPRs are also known as 'permanent...

  6. Lawful Permanent Residents Fiscal Year 2015 Country

    Data.gov (United States)

    Department of Homeland Security — Lawful permanent residents (LPRs) are foreign nationals who have been granted the right to reside permanently in the United States. LPRs are also known as 'permanent...

  7. Lawful Permanent Residents Fiscal Year 2016 State

    Data.gov (United States)

    Department of Homeland Security — Lawful permanent residents (LPRs) are foreign nationals who have been granted the right to reside permanently in the United States. LPRs are also known as 'permanent...

  8. Lawful Permanent Residents Fiscal Year 2014 State

    Data.gov (United States)

    Department of Homeland Security — Lawful permanent residents (LPRs) are foreign nationals who have been granted the right to reside permanently in the United States. LPRs are also known as 'permanent...

  9. Lawful Permanent Residents Fiscal Year 2015 State

    Data.gov (United States)

    Department of Homeland Security — Lawful permanent residents (LPRs) are foreign nationals who have been granted the right to reside permanently in the United States. LPRs are also known as 'permanent...

  10. Regulation of fields excited by permanent magnets

    International Nuclear Information System (INIS)

    Savchenko, I.S.

    1989-01-01

    Two methods of fast regulation of fields excited by permanent magnets in salient-pole electron-optical lenses are described: 1)the hybrid method realized using the additional electromagnet introduced to a magnetic chain sequentially its field being composed or substracted with magnetosolid exciter field; 2)the method with saturation of a part of a magnetic circuit, with saturation being achievable at the begining or in the end of a regulation cycle. In the second method it is proposed to direct orthogonally the main flux excited by permanent magnets and the flux in the saturated part of the magnetic circuit excited using an electromagnet. It is shown that the second method allows one to reduce the required ampere-coils by more than an order as compared to the first method at one and the same regulation range and other equal conditions. The frequency of field regulation in the experimental mock-up was 10 kHz. 3 refs.; 2 figs

  11. Sensorless Control of Permanent Magnet Synchronous Machines

    DEFF Research Database (Denmark)

    Matzen, Torben N.

    Permanent magnet machines, with either surface mounted or embedded magnets on the rotor, are becoming more common due to the key advantages of higher energy conversion efficiency and higher torque density compared to the classical induction machine. Besides energy efficiency the permanent magnet...... the synchronous machine requires knowledge of the rotor shaft position due to the synchronous and undamped nature of the machine. The rotor position may be measured using a mechanical sensor, but the sensor reduces reliability and adds cost to the system and for this reason sensorless control methods started...... are dependent on the phase currents and rotor position. Based on the flux linkages the differential inductances are determined and used to establish the inductance saliency in terms of ratio and orientation. The orientation and its dependence on the current and rotor position are used to analyse the behaviour...

  12. Three-dimensional quadrupole lenses made with permanent magnets

    International Nuclear Information System (INIS)

    Ivanov, A.S.

    1984-01-01

    The performance of accelerator systems with quadrupole magnets can be improved by using permanent magnets in quadrupole lenses. This requires better methods for treating the three-dimensional nature of the magnetic fields and the nonlinear characteristics of the magnets. A numerical method is described for simulating three-dimensional magnetic fields and used to analyze quadrupole lenses and doublets with permanent magnets. The results, which are confirmed experimentally, indicate that both the quadrupole magnetic gradient and the effective field length are changed in permanent-magnet quadrupole lenses when the pole lengths and the gap between the lenses are varied while the other characteristics of the magnets remain unchanged

  13. Study Protocol- Lumbar Epidural Steroid Injections for Spinal Stenosis (LESS: a double-blind randomized controlled trial of epidural steroid injections for lumbar spinal stenosis among older adults

    Directory of Open Access Journals (Sweden)

    Friedly Janna L

    2012-03-01

    Full Text Available Abstract Background Lumbar spinal stenosis is one of the most common causes of low back pain among older adults and can cause significant disability. Despite its prevalence, treatment of spinal stenosis symptoms remains controversial. Epidural steroid injections are used with increasing frequency as a less invasive, potentially safer, and more cost-effective treatment than surgery. However, there is a lack of data to judge the effectiveness and safety of epidural steroid injections for spinal stenosis. We describe our prospective, double-blind, randomized controlled trial that tests the hypothesis that epidural injections with steroids plus local anesthetic are more effective than epidural injections of local anesthetic alone in improving pain and function among older adults with lumbar spinal stenosis. Methods We will recruit up to 400 patients with lumbar central canal spinal stenosis from at least 9 clinical sites over 2 years. Patients with spinal instability who require surgical fusion, a history of prior lumbar surgery, or prior epidural steroid injection within the past 6 months are excluded. Participants are randomly assigned to receive either ESI with local anesthetic or the control intervention (epidural injections with local anesthetic alone. Subjects receive up to 2 injections prior to the primary endpoint at 6 weeks, at which time they may choose to crossover to the other intervention. Participants complete validated, standardized measures of pain, functional disability, and health-related quality of life at baseline and at 3 weeks, 6 weeks, and 3, 6, and 12 months after randomization. The primary outcomes are Roland-Morris Disability Questionnaire and a numerical rating scale measure of pain intensity at 6 weeks. In order to better understand their safety, we also measure cortisol, HbA1c, fasting blood glucose, weight, and blood pressure at baseline, and at 3 and 6 weeks post-injection. We also obtain data on resource utilization

  14. Effects of rosuvastatin on progression of stenosis in adult patients with congenital aortic stenosis (PROCAS Trial)

    NARCIS (Netherlands)

    Linde, D. van der; Yap, S.C.; Dijk, A.P. van; Budts, W.; Pieper, P.G.; Burgh, P.H. van der; Mulder, B.J.; Witsenburg, M.; Cuypers, J.A.; Lindemans, J.; Takkenberg, J.J.; Roos-Hesselink, J.W.

    2011-01-01

    Recent trials have failed to show that statin therapy halts the progression of calcific aortic stenosis (AS). We hypothesized that statin therapy in younger patients with congenital AS would be more beneficial, because the valve is less calcified. In the present double-blind, placebo-controlled

  15. Balancing permanent magnet arrays

    NARCIS (Netherlands)

    Krechting, P.T.; Lomonova, E.; Jansen, J.W.

    2009-01-01

    High resolution electron beam imaging (E-beam) has found wide usage in industry in photolithography and semiconductor inspection systems. E-beam inspection, which takes place in vacuum, is very sensitive to magnetic fields, and requires highly dynamic and accurate actuators Piezo "walking" motors

  16. Closure requirements

    International Nuclear Information System (INIS)

    Hutchinson, I.P.G.; Ellison, R.D.

    1992-01-01

    Closure of a waste management unit can be either permanent or temporary. Permanent closure may be due to: economic factors which make it uneconomical to mine the remaining minerals; depletion of mineral resources; physical site constraints that preclude further mining and beneficiation; environmental, regulatory or other requirements that make it uneconomical to continue to develop the resources. Temporary closure can occur for a period of several months to several years, and may be caused by factors such as: periods of high rainfall or snowfall which prevent mining and waste disposal; economic circumstances which temporarily make it uneconomical to mine the target mineral; labor problems requiring a cessation of operations for a period of time; construction activities that are required to upgrade project components such as the process facilities and waste management units; and mine or process plant failures that require extensive repairs. Permanent closure of a mine waste management unit involves the provision of durable surface containment features to protect the waters of the State in the long-term. Temporary closure may involve activities that range from ongoing maintenance of the existing facilities to the installation of several permanent closure features in order to reduce ongoing maintenance. This paper deals with the permanent closure features

  17. Radiographic indices for lumbar developmental spinal stenosis

    Directory of Open Access Journals (Sweden)

    Jason Pui Yin Cheung

    2017-02-01

    Full Text Available Abstract Background Patients with developmental spinal stenosis (DSS are susceptible to developing symptomatic stenosis due to pre-existing narrowed spinal canals. DSS has been previously defined by MRI via the axial anteroposterior (AP bony spinal canal diameter. However, MRI is hardly a cost-efficient tool for screening patients. X-rays are superior due to its availability and cost, but currently, there is no definition of DSS based on plain radiographs. Thus, the aim of this study is to develop radiographic indices for diagnosing DSS. Methods This was a prospective cohort of 148 subjects consisting of patients undergoing surgery for lumbar spinal stenosis (patient group and asymptomatic subjects recruited openly from the general population (control group. Ethics approval was obtained from the local institutional review board. All subjects underwent MRI for diagnosing DSS and radiographs for measuring parameters used for creating the indices. All measurements were performed by two independent investigators, blinded to patient details. Intra- and interobserver reliability analyses were conducted, and only parameters with near perfect intraclass correlation underwent receiver operating characteristic (ROC analysis to determine the cutoff values for diagnosing DSS using radiographs. Results Imaging parameters from a total of 66 subjects from the patient group and 82 asymptomatic subjects in the control group were used for analysis. ROC analysis suggested sagittal vertebral body width to pedicle width ratio (SBW:PW as having the strongest sensitivity and specificity for diagnosing DSS. Cutoff indices for SBW:PW were level-specific: L1 (2.0, L2 (2.0, L3 (2.2, L4 (2.2, L5 (2.5, and S1 (2.8. Conclusions This is the first study to define DSS on plain radiographs based on comparisons between a clinically relevant patient group and a control group. Individuals with DSS can be identified by a simple radiograph using a screening tool allowing for better

  18. Interventional treatment of transplanted renal artery stenosis

    International Nuclear Information System (INIS)

    Zhang Zefu; Liang Huiming; Feng Gansheng; Zheng Chuansheng; Wu Hanpin; Zhou Guofeng

    2008-01-01

    Objective: To evaluate the treatment of transplanted renal artery stenosis (TRAS) by pereutaneous transluminal angioplasty (PTA)and stentplacement. Methods: The averange time from trans- plantation to the symptom occurrence of TRAS was 5.5 months (4-15 months)in 12 TRAS patients. All of them received the interventional therapy through femoral approach. Average BP, creatinine level and stenosis before and after the procedure were taken as the judgement standards. Results: PTA was performed with balloon (length 20-40 mm, diameter 5-7 mm)in 4 patients, stenting after PTA in 5, including 3 of direct stenting. Two cases (17%)occurred restenosis after PTA and restenting was undertaken. Three ases (25%)with restenosis after stentplacement were undergone PTA. One self-expandable stent and 9 balloon- dilatation stent were released in 10 eases. Stenosis significantly decreased from 65%-95% preoperatively to 15%-25% postoperatively, together with average BP decreased from 175/105 mmHg to 140/80 mmHg and creatinine level decreased from 475.5 μmol/L to 118.5 μmol/L. Among 12 cases included 4 healed, melioration (5), improvement (2), and inefficiency (1) during follow-up of 9 months (3-24 months). No complication occurred. Conclusion: The interventional therapy is effective and safe for TRAS with high rates of procedure success and efficacy. The proper selection of the adapted approach combined with PTA and stenting may effectively raise the long term efficacy for TRAS and success rate of the procedure. (authors)

  19. Membraneous stenosis of the upper oesophagus ('webs')

    International Nuclear Information System (INIS)

    Koch, H.L.; Kurtz, B.

    1981-01-01

    Webs of the upper oesophagus are sail-like mucosal folds of unknown aetiology. Small, transverse webs on the anterior wall of the oesophagus are not uncommon incidental findings which are easily overlooked on routine examination. Extensive, circular membranes in the upper oesophagus, on the other hand, are rare; these may lead to severe difficulty with swallowing and may be associated with regurgitation. One example of a transverse, and three cases of circular webs are described, which caused stenosis and dysphagia and which, in some cases, were multiple. The aetiology is discussed. (orig.) [de

  20. [Enlargement in managment of lumbar spinal stenosis].

    Science.gov (United States)

    Steib, J P; Averous, C; Brinckert, D; Lang, G

    1996-05-01

    Lumbar stenosis has been well discussed recently, especially at the 64th French Orthopaedic Society (SOFCOT: July 1989). The results of different surgical treatments were considered as good, but the indications for surgical treatment were not clear cut. Laminectomy is not the only treatment of spinal stenosis. Laminectomy is an approach with its own rate of complications (dural tear, fibrosis, instability... ).Eight years ago, J. Sénégas described what he called the "recalibrage" (enlargement). His feeling was that, in the spinal canal, we can find two different AP diameters. The first one is a fixed constitutional AP diameter (FCAPD) at the cephalic part of the lamina. The second one is a mobile constitutional AP diameter (MCAPD) marked by the disc and the ligamentum flavum. This diameter is maximal in flexion, minimal in extension. The nerve root proceeds through the lateral part of the canal: first above, between the disc and the superior articular process, then below, in the lateral recess bordered by the pedicle, the vertebral body and the posterior articulation. With the degenerative change the disc space becomes shorter, the superior articular process is worn out with osteophytes. These degenerative events are complicated by inter vertebral instability increasing the stenosis. The idea of the "recalibrage" is to remove only the upper part of the lamina with the ligamentum flavum and to cut the hypertrophied anterior part of the articular process from inside. If needed the disc and other osteophytes are removed. The surgery is finished with a ligamentoplasty reducing the flexion and preventing the extension by a posterior wedge.Our experience in spine surgery especially in scoliosis surgery, showed us that it was possible to cure a radicular compression without opening the canal. The compression is then lifted by the 3D reduction and restoration of an anatomy as normal as possible. Lumbar stenosis is the consequence of a degenerative process. Indeed, hip

  1. Bovine aortic arch with supravalvular aortic stenosis.

    Science.gov (United States)

    Idhrees, Mohammed; Cherian, Vijay Thomas; Menon, Sabarinath; Mathew, Thomas; Dharan, Baiju S; Jayakumar, K

    2016-09-01

    A 5-year-old boy was diagnosed to have supravalvular aortic stenosis (SVAS). On evaluation of CT angiogram, there was associated bovine aortic arch (BAA). Association of BAA with SVAS has not been previously reported in literature, and to best of our knowledge, this is the first case report of SVAS with BAA. Recent studies show BAA as a marker for aortopathy. SVAS is also an arteriopathy. In light of this, SVAS can also possibly be a manifestation of aortopathy associated with BAA. Copyright © 2015 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  2. Bovine aortic arch with supravalvular aortic stenosis

    Directory of Open Access Journals (Sweden)

    Mohammed Idhrees

    2016-09-01

    Full Text Available A 5-year-old boy was diagnosed to have supravalvular aortic stenosis (SVAS. On evaluation of CT angiogram, there was associated bovine aortic arch (BAA. Association of BAA with SVAS has not been previously reported in literature, and to best of our knowledge, this is the first case report of SVAS with BAA. Recent studies show BAA as a marker for aortopathy. SVAS is also an arteriopathy. In light of this, SVAS can also possibly be a manifestation of aortopathy associated with BAA.

  3. Esophageal stenosis after radiation for laryngeal carcinoma

    International Nuclear Information System (INIS)

    Takeuchi, Kazuhiko; Majima, Yuichi; Nomoto, Yoshito; Okamoto, Yasunori; Sakakura, Yasuo

    1995-01-01

    A 57-year-old female received radiation with 60 Gy, delivered by Cobalt 60 unit for laryngeal carcinoma in 1989. Several months later she complained of dyspnea, and fiberscopic observation revealed fixation of bilateral vocal cords and a swelling of bilateral arytenoid portions. In 1990, she developed difficulty swallowing. Further examinations showed that the cervical esophagus was extremely narrowed but no malignancy was found either in the larynx or in the esophagus. We suspected that the esophageal stenosis was caused by post-radiation fibrosis. (author)

  4. Esophageal stenosis after radiation for laryngeal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Takeuchi, Kazuhiko; Majima, Yuichi; Nomoto, Yoshito; Okamoto, Yasunori; Sakakura, Yasuo [Mie Univ., Tsu (Japan). School of Medicine

    1995-10-01

    A 57-year-old female received radiation with 60 Gy, delivered by Cobalt 60 unit for laryngeal carcinoma in 1989. Several months later she complained of dyspnea, and fiberscopic observation revealed fixation of bilateral vocal cords and a swelling of bilateral arytenoid portions. In 1990, she developed difficulty swallowing. Further examinations showed that the cervical esophagus was extremely narrowed but no malignancy was found either in the larynx or in the esophagus. We suspected that the esophageal stenosis was caused by post-radiation fibrosis. (author).

  5. Computer tomographic investigations of cervical spinal stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Rodiek, S.O.

    1983-10-01

    Computed tomography was applied in 29 patients with cervical spinal stenosis. In 8 cases there was a congenital narrowed spinal canal. In 18 cases we found dorsal spondylotic ridges of the vertebral bodies and in three cases an atlanto-dental dislocation. The complaints showed either radicular character or in case of myelopathy came out as para- and quadriplegia. In 25 cases the spinal sagittal diamter was a lot below a critical borderline of about 13 mm. The kind and localisation of the underlying process can be demonstrated very excellent by computed tomography.

  6. Computer tomographic investigations of cervical spinal stenosis

    International Nuclear Information System (INIS)

    Rodiek, S.O.

    1983-01-01

    Computed tomography was applied in 29 patients with cervical spinal stenosis. In 8 cases there was a congenital narrowed spinal canal. In 18 cases we found dorsal spondylotic ridges of the vertebral bodies and in three cases an atlanto-dental dislocation. The complaints showed either radicular character or in case of myelopathy came out as para- and quadriplegia. In 25 cases the spinal sagittal diamter was a lot below a critical borderline of about 13 mm. The kind and localisation of the underlying process can be demonstrated very excellent by computed tomography. (orig.) [de

  7. Rare earth permanent magnet with easy magnetization

    International Nuclear Information System (INIS)

    Kim, A.S.; Camp, F.E.

    1998-01-01

    Rare earth permanent magnets have high energy products and coercivities, and thus the volume miniaturization of magnetic devices has been possible with improved magnetic performance. Although the high energy products of these rare earth permanent magnets provide substantial advantages for magnetic design and application, the strong magnetic force of the magnetized magnets makes assembly difficult. Therefore, a special device is needed to assemble the magnetized magnets. On the other hand, unmagnetized magnets are assembled and then they are magnetized. The assembled magnets are generally more difficult to magnetize than unassembled magnets because a much less effective magnetic field may be applied to them. This is particularly true for the rare earth permanent magnets because they usually need a much higher magnetic field to be fully magnetized than alnico or ferrite magnets. To obtain optimum magnetic properties, the required minimum magnetizing fields for SmCo 5 , Sm 2 TM 17 and Nd 2 Fe 14 B magnets were reported as 25-30 kOe, 45-60 kOe and 25-30 kOe, respectively. If the required magnetizing field for full saturation could be lowered, the effective utilization of magnetic properties would be maximized and the magnetic design option could be expanded with reduced restrictions. To meet this demand, we have sought to lower the field required for full magnetic saturation, and found that an increase in Dy content in R-(Fe,Co,Cu)-B type magnets lowers the field required for full saturation as well as improves the temperature stability. By increasing the H ci with Dy addition from 14 kOe to 24 and 34 kOe, the field required for full magnetic saturation decreases from about 20 to 15 and 10 kOe, respectively. This dual benefit will open up new application areas with more freedom for magnet design options. The mechanism for the lower magnetizing fields will be discussed. (orig.)

  8. Resection and anastomosis for benign tracheal stenosis: Single institution experience of 18 cases.

    Science.gov (United States)

    Kumar, Arvind; Asaf, Belal Bin; Puri, Harsh Vardhan; Abdellateef, Amr

    2017-01-01

    Tracheal stenosis is a complex condition caused by altered inflammatory response to injury and subsequent excessive circumferential scar formation. Surgical resection, wherever possible, offers the best long-term results. Nonsurgical methods provide immediate relief to all can be curative in few but mostly serve as an excellent bridge to surgery in majority. The purpose of this study is to retrospectively evaluate the outcome following surgery for benign tracheal stenosis at our center. This retrospective analysis was conducted on 18 patients who underwent resection and anastomosis for tracheal stenosis at our center between March 2012 and December 2015. Their records were analyzed for demography, history, clinical presentation, computed tomography, bronchoscopy details, preoperative interventions, indications for and details of surgery, the procedure performed, postoperative complications, and course during 6 months follow-up. The patients had a varied list of pathologies for which they were either intubated or tracheostomized. The length of stenosis ranged between 1 cm and 4 cm. The diameter of stenotic segment ranged between 0 mm and 10 mm. Average length of resected segment was 3 cm, and number of tracheal rings resected ranged from 2 to 9. Postoperative complications occurred in four patients (22.22%). All our patients were in the "excellent outcome" category at discharge as well as at 3 months follow-up. Surgical management of tracheal stenosis is challenging and requires multidisciplinary team approach. Thorough preoperative preparation and multidisciplinary planning regarding need for and timing of surgery, meticulous intraoperative technique, and aggressive postoperative care is key to successful surgery, which can provide long-lasting cure to these patients.

  9. Resection and anastomosis for benign tracheal stenosis: Single institution experience of 18 cases

    Directory of Open Access Journals (Sweden)

    Arvind Kumar

    2017-01-01

    Full Text Available Introduction: Tracheal stenosis is a complex condition caused by altered inflammatory response to injury and subsequent excessive circumferential scar formation. Surgical resection, wherever possible, offers the best long-term results. Nonsurgical methods provide immediate relief to all can be curative in few but mostly serve as an excellent bridge to surgery in majority. The purpose of this study is to retrospectively evaluate the outcome following surgery for benign tracheal stenosis at our center. Materials and Methods: This retrospective analysis was conducted on 18 patients who underwent resection and anastomosis for tracheal stenosis at our center between March 2012 and December 2015. Their records were analyzed for demography, history, clinical presentation, computed tomography, bronchoscopy details, preoperative interventions, indications for and details of surgery, the procedure performed, postoperative complications, and course during 6 months follow-up. Results: The patients had a varied list of pathologies for which they were either intubated or tracheostomized. The length of stenosis ranged between 1 cm and 4 cm. The diameter of stenotic segment ranged between 0 mm and 10 mm. Average length of resected segment was 3 cm, and number of tracheal rings resected ranged from 2 to 9. Postoperative complications occurred in four patients (22.22%. All our patients were in the “excellent outcome” category at discharge as well as at 3 months follow-up. Conclusions: Surgical management of tracheal stenosis is challenging and requires multidisciplinary team approach. Thorough preoperative preparation and multidisciplinary planning regarding need for and timing of surgery, meticulous intraoperative technique, and aggressive postoperative care is key to successful surgery, which can provide long-lasting cure to these patients.

  10. Treatment of right ventricle to pulmonary artery conduit stenosis in infants with hypoplastic left heart syndrome.

    Science.gov (United States)

    Münsterer, Andrea; Kasnar-Samprec, Jelena; Hörer, Jürgen; Cleuziou, Julie; Eicken, Andreas; Malcic, Ivan; Lange, Rüdiger; Schreiber, Christian

    2013-09-01

    To determine the incidence of right ventricle-to-pulmonary artery (RV-PA) conduit stenosis after the Norwood I operation in patients with hypoplastic left heart syndrome (HLHS), and to determine whether the treatment strategy of RV-PA conduit stenosis has an influence on interstage and overall survival. Ninety-six patients had a Norwood operation with RV-PA conduit between 2002 and 2011. Details of reoperations/interventions due to conduit obstruction prior to bidirectional superior cavopulmonary anastomosis (BSCPA) were collected. Overall pre-BSCPA mortality was 17%, early mortality after Norwood, 6%. Early angiography was performed in 34 patients due to desaturation at a median of 8 days after the Norwood operation. Fifteen patients (16%) were diagnosed with RV-PA conduit stenosis that required treatment. The location of the conduit stenosis was significantly different in the patients with non-ringed (proximal) and the patients with ring-enforced conduit (distal), P = 0.004. In 6 patients, a surgical revision of the conduit was performed; 3 of them died prior to BSCPA. Another 6 patients had a stent implantation and 3 were treated with balloon dilatation followed by a BSCPA in the subsequent 2 weeks. All patients who were treated interventionally for RV-PA conduit obstruction had a successful BSCPA. Patients who received a surgical RV-PA conduit revision had a significantly higher interstage (P = 0.044) and overall mortality (P = 0.011) than those who received a stent or balloon dilatation of the stenosis followed by an early BSCPA. RV-PA conduit obstruction after Norwood I procedure in patients with HLHS can be safely and effectively treated by stent implantation, balloon dilatation and early BSCPA. Surgical revision of the RV-PA conduit can be reserved for patients in whom an interventional approach fails, and an early BSCPA is not an option.

  11. Permanent underwater leak detector

    International Nuclear Information System (INIS)

    Costello, L; McStay, D; Moodie, D; Kane, D

    2009-01-01

    A new optoelectronic sensor for the real time monitoring of key components such as valves and connectors within the subsea production equipment for leaks of hydraulic fluid is reported. The sensor is capable of detecting low concentrations of such fluids, allowing the early detection of small leaks, and the ability to monitor the evolution of the leak-rate with time, hence providing an important new tool in complying with environmental requirements, enabling early intervention and optimising subsea production

  12. Stenosis differentially affects subendocardial and subepicardial arterioles in vivo

    NARCIS (Netherlands)

    Merkus, D.; Vergroesen, I.; Hiramatsu, O.; Tachibana, H.; Nakamoto, H.; Toyota, E.; Goto, M.; Ogasawara, Y.; Spaan, J. A.; Kajiya, F.

    2001-01-01

    The presence of a coronary stenosis results primarily in subendocardial ischemia. Apart from the decrease in coronary perfusion pressure, a stenosis also decreases coronary flow pulsations. Applying a coronary perfusion system, we compared the autoregulatory response of subendocardial (n = 10) and

  13. Discrete subvalvular aortic stenosis in the Beckwith-Wiedemann syndrome.

    Science.gov (United States)

    Shirani, J; Natarajan, K; Varga, P; Vitullo, D A

    1993-07-01

    Various congenital cardiac malformations have been described in patients with Beckwith-Wiedemann (BW) syndrome, including reversible obstructive subaortic stenosis in one patient. We herein present a case of a 2.5-year-old black boy with BW syndrome and discrete subvalvular aortic stenosis of the membraneous type. Such association of these two entities has previously not been documented.

  14. Intensive lipid lowering with simvastatin and ezetimibe in aortic stenosis

    DEFF Research Database (Denmark)

    Rossebo, A.B.; Pedersen, T.R.; Boman, K.

    2008-01-01

    BACKGROUND: Hyperlipidemia has been suggested as a risk factor for stenosis of the aortic valve, but lipid-lowering studies have had conflicting results. METHODS: We conducted a randomized, double-blind trial involving 1873 patients with mild-to-moderate, asymptomatic aortic stenosis. The patients...

  15. Percutaneous balloon valvuloplasty in mitral stenosis

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Oh, Byung Hee; Park, Kyung Ju; Kim, Seung Hyup; Lee, Young Woo; Han, Man Chung

    1989-01-01

    Percutaneous balloon valvuloplasty(PBV) was successfully performed in 8 mitral stenosis patients for recent 3 months. Five patients have aortic insufficiencies also and two patients have mitral regurgitations below grade II/IV. All patients showed sinus rhythm on EKG, and had no mitral valvular calcification on echocardiography and fluoroscopy. PBV resulted in an increase in mitral valve area from 1.22±0.22 to 2.57±0.86 cm 2 , a decrease in mean left atrial pressure from 23.4±9.6 to 7.5±3.4 mmHg and a decrease in mean mitral pressure gradient from 21.3±9.4 to 6.8±3.1 mmHg. There were no significant complications except 2 cases of newly appeared and mildly aggravated mitral regurgitation. We believe that PBV will become a treatment modality of choice replacing surgical commissurotomy or valve replacement in a group of mitral stenosis patients, because of its effectiveness and safety

  16. Diagnostic imaging of hypertrophic pyloric stenosis (HPS)

    International Nuclear Information System (INIS)

    Frkovic, M.; Seronja Kuhar, M.; Perhoc, Z.; Barbaric-Babic, V.; Molnar, M.; Vukovic, J.

    2001-01-01

    Background. Imaging of the abdomen in children with suspected hypertrophic pyloric stenosis has been traditionally performed by plain film radiography and upper gastrointestinal contrast studies. In many clinical situations, this approach has been modified or replaced by ultrasound examination. The authors aimed to analyse the value of diagnostic algorithm in children with hypertrophic pyloric stenosis confirmed at surgery in our hospital. Patients and methods. The authors made a five year retrospective review of hospital records of all children operated on for HPS in Clinical Hospital Centre Zagreb - Rebro and found out that 14 boys, between 2 (17 days) and 10 weeks of life (75 days) underwent surgery due to HPS. Results. Specific radiographic signs were: string sign, double track sign, elongation and narrowing of pyloric canal, mushroom sign, gastric distension with fluid and beak sign. Ultrasound was performed in 9 patients, one of them was false negative (sonographer admitted that he had no experience), the rest were positive. Conclusions. If the physical examination is negative or equivocal, sonography by an experienced sonographer must be performed. If the ultrasound finding is negative, than the infant should undergo to barium upper gastrointestinal studies (UGI). If HPS isn't a primary diagnostic question, it's better to perform UGI first in order to make a correct diagnosis. (author)

  17. Fibrin Sheath Angioplasty: A Technique to Prevent Superior Vena Cava Stenosis Secondary to Dialysis Catheters

    Science.gov (United States)

    Hacker, Robert I.; Garcia, Lorena De Marco; Chawla, Ankur; Panetta, Thomas F.

    2012-01-01

    Fibrin sheaths are a heterogeneous matrix of cells and debris that form around catheters and are a known cause of central venous stenosis and catheter failure. A total of 50 cases of central venous catheter fibrin sheath angioplasty (FSA) after catheter removal or exchange are presented. A retrospective review of an outpatient office database identified 70 eligible patients over a 19-month period. After informed consent was obtained, the dialysis catheter exiting the skin was clamped, amputated, and a wire was inserted. The catheter was then removed and a 9-French sheath was inserted into the superior vena cava, a venogram was performed. If a fibrin sheath was present, angioplasty was performed using an 8 × 4 or 10 × 4 balloon along the entire length of the fibrin sheath. A completion venogram was performed to document obliteration of the sheath. During the study, 50 patients were diagnosed with a fibrin sheath, and 43 had no pre-existing central venous stenosis. After FSA, 39 of the 43 patient's (91%) central systems remained patent without the need for subsequent interventions; 3 patients (7%) developed subclavian stenoses requiring repeat angioplasty and stenting; 1 patent (2.3%) developed an occlusion requiring a reintervention. Seven patients with prior central stenosis required multiple angioplasties; five required stenting of their central lesions. Every patient had follow-up fistulograms to document long-term patency. We propose that FSA is a prudent and safe procedure that may help reduce the risk of central venous stenosis from fibrin sheaths due to central venous catheters. PMID:23997555

  18. Stroke prevention-surgical and interventional approaches to carotid stenosis

    Directory of Open Access Journals (Sweden)

    Kumar Rajamani

    2013-01-01

    Full Text Available Extra cranial carotid artery stenosis is an important cause of stroke, which often needs treatment with carotid revascularization. To prevent stroke recurrence, carotid endarterectomy (CEA has been well-established for several decades for symptomatic high and moderate grade stenosis. Carotid stenting is a less invasive alternative to CEA and several recent trials have compared the efficacy of the 2 procedures in patients with carotid stenosis. Carotid artery stenting has emerged as a potential mode of therapy for high surgical risk patients with symptomatic high-grade stenosis. This review focuses on the current data available that will enable the clinician to decide optimal treatment strategies for patients with carotid stenosis.

  19. Diagnosis of Lumbar Foraminal Stenosis using Diffusion Tensor Imaging.

    Science.gov (United States)

    Eguchi, Yawara; Ohtori, Seiji; Suzuki, Munetaka; Oikawa, Yasuhiro; Yamanaka, Hajime; Tamai, Hiroshi; Kobayashi, Tatsuya; Orita, Sumihisa; Yamauchi, Kazuyo; Suzuki, Miyako; Aoki, Yasuchika; Watanabe, Atsuya; Kanamoto, Hirohito; Takahashi, Kazuhisa

    2016-02-01

    Diagnosis of lumbar foraminal stenosis remains difficult. Here, we report on a case in which bilateral lumbar foraminal stenosis was difficult to diagnose, and in which diffusion tensor imaging (DTI) was useful. The patient was a 52-year-old woman with low back pain and pain in both legs that was dominant on the right. Right lumbosacral nerve compression due to a massive uterine myoma was apparent, but the leg pain continued after a myomectomy was performed. No abnormalities were observed during nerve conduction studies. Computed tomography and magnetic resonance imaging indicated bilateral L5 lumbar foraminal stenosis. DTI imaging was done. The extraforaminal values were decreased and tractography was interrupted in the foraminal region. Bilateral L5 vertebral foraminal stenosis was treated by transforaminal lumbar interbody fusion and the pain in both legs disappeared. The case indicates the value of DTI for diagnosing vertebral foraminal stenosis.

  20. Use of Self-Expanding Metallic Ureteral Stents in the Secondary Treatment of Ureteral Stenosis Following Kidney Transplantation.

    Science.gov (United States)

    Xu, Guibin; Li, Xun; He, Yongzhong; Zhao, Haibo; Yang, Weiqing; Xie, Qingling

    2015-10-01

    To evaluate the safety and efficacy of self-expanding metal stents in the treatment of ureteral stenosis following kidney transplantation. Seven patients who developed benign stenosis after kidney transplantation were treated by a self-expanding metallic stent implantation from June 2007 to March 2014. All patients had undergone at least one open surgical procedure and one endourologic procedure for treatment of the stenosis. The extent of stenosis varied from 1.2 to 3.7 cm. Ultrasonography, urography, diuretic renography, and urine culture were performed every 3 months after stent insertion. Ureteroscopic examination was performed when needed. Stent placement was technically effective in all cases. The mean operative time was 37 minutes (range, 26-59 minutes). Lower urinary-tract symptoms and the ipsilateral flank pain were common early-stage complications and were greatly relieved after an average of 3 months. The mean follow-up duration was 38 months (range, 13-86 months), and no stent migration or fragmentation was observed. Urothelial hyperplasia occurred in only one patient and was effectively managed with a Double-J stent. Five patients had normal stable renal function; the remaining two had impaired renal function, including one patient with a preoperative renal failure who required dialysis at the end of the follow-up period (36 months). As an alternative to open surgery, implantation of a self-expanding metal stent is a safe and effective treatment for ureteral stenosis in patients who have undergone kidney transplantation.

  1. Treatment of multiple-level tracheobronchial stenosis secondary to endobronchial tuberculosis using bronchoscopic balloon dilatation with topical mitomycin-C.

    Science.gov (United States)

    Faisal, Mohamed; Harun, Hafaruzi; Hassan, Tidi M; Ban, Andrea Y L; Chotirmall, Sanjay H; Abdul Rahaman, Jamalul Azizi

    2016-04-14

    Tracheobronchial stenosis is a known complication of endobronchial tuberculosis. Despite antituberculous and steroid therapy, the development of bronchial stenosis is usually irreversible and requires airway patency to be restored by either bronchoscopic or surgical interventions. We report the use of balloon dilatation and topical mitomycin-C to successful restore airway patency. We present a 24-year old lady with previous pulmonary tuberculosis and laryngeal tuberculosis in 2007 and 2013 respectively who presented with worsening dyspnoea and stridor. She had total left lung collapse with stenosis of both the upper trachea and left main bronchus. She underwent successful bronchoscopic balloon and manual rigid tube dilatation with topical mitomycin-C application over the stenotic tracheal segment. A second bronchoscopic intervention was performed after 20 weeks for the left main bronchus stenosis with serial balloon dilatation and topical mitomycin-C application. These interventions led to significant clinical and radiographic improvements. This case highlights that balloon dilatation and topical mitomycin-C application should be considered in selected patients with tracheobronchial stenosis following endobronchial tuberculosis, avoiding airway stenting and invasive surgical intervention.

  2. Analysis of the Sensitivity and Specificity of Noninvasive Imaging Tests for the Diagnosis of Renal Artery Stenosis

    International Nuclear Information System (INIS)

    Borelli, Flavio Antonio de Oliveira; Pinto, Ibraim M. F.; Amodeo, Celso; Smanio, Paola E. P.; Kambara, Antonio M.; Petisco, Ana Claudia G.; Moreira, Samuel M.; Paiva, Ricardo Calil; Lopes, Hugo Belotti; Sousa, Amanda G. M. R.

    2013-01-01

    Aging and atherosclerosis are related to renovascular hypertension in elderly individuals. Regardless of comorbidities, renal artery stenosis is itself an important cause of cardiovascular morbidity and mortality. To define the sensitivity, specificity, positive predictive value, and negative predictive value of noninvasive imaging tests used in the diagnosis of renal artery stenosis. In a group of 61 patients recruited, 122 arteries were analized, thus permitting the definition of sensitivity, specificity, and the relative contribution of each imaging study performed (Doppler, scintigraphy and computed tomographic angiography in comparison to renal arteriography). The mean age was 65.43 years (standard deviation: 8.7). Of the variables related to the study population that were compared to arteriography, two correlated with renal artery stenosis, renal dysfunction and triglycerides. The median glomerular filtration rate was 52.8 mL/min/m 2 . Doppler showed sensitivity of 82.90%, specificity of 70%, a positive predictive value of 85% and negative predictive value of 66.70%. For tomography, sensitivity was 66.70%, specificity 80%, positive predictive value 87.50% and negative predictive value 55.20%. With these findings, we could identify the imaging tests that best detected stenosis. Tomography and Doppler showed good quality and efficacy in the diagnosis of renal artery stenosis, with Doppler having the advantage of not requiring the use of contrast medium for the assessment of a disease that is common in diabetics and is associated with renal dysfunction and severe left ventricular dysfunction

  3. Analysis of the Sensitivity and Specificity of Noninvasive Imaging Tests for the Diagnosis of Renal Artery Stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Borelli, Flavio Antonio de Oliveira, E-mail: fborelli@cardiol.br; Pinto, Ibraim M. F.; Amodeo, Celso; Smanio, Paola E. P.; Kambara, Antonio M.; Petisco, Ana Claudia G.; Moreira, Samuel M.; Paiva, Ricardo Calil; Lopes, Hugo Belotti; Sousa, Amanda G. M. R. [Instituto Dante Pazzanese de Cardiologia, São Paulo, SP (Brazil)

    2013-11-15

    Aging and atherosclerosis are related to renovascular hypertension in elderly individuals. Regardless of comorbidities, renal artery stenosis is itself an important cause of cardiovascular morbidity and mortality. To define the sensitivity, specificity, positive predictive value, and negative predictive value of noninvasive imaging tests used in the diagnosis of renal artery stenosis. In a group of 61 patients recruited, 122 arteries were analized, thus permitting the definition of sensitivity, specificity, and the relative contribution of each imaging study performed (Doppler, scintigraphy and computed tomographic angiography in comparison to renal arteriography). The mean age was 65.43 years (standard deviation: 8.7). Of the variables related to the study population that were compared to arteriography, two correlated with renal artery stenosis, renal dysfunction and triglycerides. The median glomerular filtration rate was 52.8 mL/min/m{sup 2}. Doppler showed sensitivity of 82.90%, specificity of 70%, a positive predictive value of 85% and negative predictive value of 66.70%. For tomography, sensitivity was 66.70%, specificity 80%, positive predictive value 87.50% and negative predictive value 55.20%. With these findings, we could identify the imaging tests that best detected stenosis. Tomography and Doppler showed good quality and efficacy in the diagnosis of renal artery stenosis, with Doppler having the advantage of not requiring the use of contrast medium for the assessment of a disease that is common in diabetics and is associated with renal dysfunction and severe left ventricular dysfunction.

  4. Transient or permanent fisheye views

    DEFF Research Database (Denmark)

    Jakobsen, Mikkel Rønne; Hornbæk, Kasper

    2012-01-01

    Transient use of information visualization may support specific tasks without permanently changing the user interface. Transient visualizations provide immediate and transient use of information visualization close to and in the context of the user’s focus of attention. Little is known, however......, about the benefits and limitations of transient visualizations. We describe an experiment that compares the usability of a fisheye view that participants could call up temporarily, a permanent fisheye view, and a linear view: all interfaces gave access to source code in the editor of a widespread...... programming environment. Fourteen participants performed varied tasks involving navigation and understanding of source code. Participants used the three interfaces for between four and six hours in all. Time and accuracy measures were inconclusive, but subjective data showed a preference for the permanent...

  5. Permanent Pacemaker-Induced Superior Vena Cava Syndrome: Successful Treatment by Endovascular Stent

    International Nuclear Information System (INIS)

    Lanciego, Carlos; Rodriguez, Mario; Rodriguez, Adela; Carbonell, Miguel A.; Garcia, Lorenzo Garcia

    2003-01-01

    The use of metallic stents in the management of benign and malignant superior vena cava syndrome (SVCS) is well documented. Symptomatic stenosis or occlusion of the SVC is a rare complication of a transvenous permanent pacemaker implant. Suggested treatments have included anticoagulation therapy, thrombolysis, balloon angioplasty and surgery. More recently, endovascular stenting has evolved as an attractive alternative but the data available in the literature are limited. We describe a case in which venous stenting with a Wallstent endoprosthesis was used successfully. The patient remains symptom free and with normal pacemaker function 36 months later

  6. Connecting Temporary and Permanent Organizing

    DEFF Research Database (Denmark)

    Stjerne, Iben Sandal; Velikova, Silviya Svejenova

    2016-01-01

    This paper investigates the relationship between a permanent organization and a series of temporary organizations. It draws on an in-depth study of the process through which a Danish film production company, seeking to balance innovation and persistence in a troubled industry, struggles to realize...... a novel children’s film and its sequels. The study reveals tensions at different levels as well as boundary work and boundary roles that address them, bringing in shadows of past and future projects. The study extends the understanding of the dialectic between temporary and permanent organizing...

  7. A randomized trial comparing primary angioplasty versus stent placement for symptomatic intracranial stenosis

    Science.gov (United States)

    Qureshi, Adnan I; Chaudhry, Saqib A; Siddiq, Farhan; Majidi, Shahram; Rodriguez, Gustavo J; Suri, M Fareed K

    2013-01-01

    Background: Both primary angioplasty alone and angioplasty with a self-expanding stent have been compared in non-randomized concurrent clinical studies that suggest equivalent results. However, there is no randomized trial that has compared the two procedures in patients with symptomatic high grade intracranial stenosis. Objective: The primary aim of the randomized trial was to compare the clinical and angiographic efficacy of primary angioplasty and angioplasty followed by stent placement in preventing restenosis, stroke, requirement for second treatment, and death in patients with symptomatic intracranial stenosis. Methods: The study prospectively evaluated efficacy and safety of the two existing neurointerventional techniques for treatment of moderate intracranial stenosis (stenosis ≥ 50%) with documented failure of medical treatment or severe stenosis (≥70%) with or without failure of medical treatment. Results: A total of 18 patients were recruited in the study (mean age [±SD] was 64.7 ± 15.1 years); out of these, 12 were men. Of these 18, 10 were treated with primary angioplasty and 8 were treated with angioplasty followed by self-expanding stent. The technical success rates of intracranial angioplasty and stent placements defined as ability to achieve <30% residual stenosis when assessed by immediate post-procedure angiography was 5 of 10 and 5 of 8 patients, respectively. The total fluoroscopic time (mean [±SD]) was lower in patients undergoing primary angioplasty 37 [±11] min versus those undergoing angioplasty followed by self-expanding stent 42 [±15] min, P = 0.4321. The stroke and death rate within 1 month was very low in both patient groups (1 of 10 versus 0 of 8 patients). One patient randomized to stent placement continued to have recurrent ischemic symptoms requiring another angioplasty in the vertebral artery on post-procedure Day 2. Conclusions: The trial suggests that a randomized trial comparing primary angioplasty to angioplasty

  8. Permanent Closure of the TAN-664 Underground Storage Tank

    Energy Technology Data Exchange (ETDEWEB)

    Bradley K. Griffith

    2011-12-01

    This closure package documents the site assessment and permanent closure of the TAN-664 gasoline underground storage tank in accordance with the regulatory requirements established in 40 CFR 280.71, 'Technical Standards and Corrective Action Requirements for Owners and Operators of Underground Storage Tanks: Out-of-Service UST Systems and Closure.'

  9. Close to Transplant Renal Artery Stenosis and Percutaneous Transluminal Treatment

    Directory of Open Access Journals (Sweden)

    Leonardou Polytimi

    2011-01-01

    Full Text Available Purpose. To evaluate the efficacy of percutaneous transluminal angioplasty (PTA in the management of arterial stenosis located close to the allograft anastomosis (close-TRAS. Materials and Methods. 31 patients with renal transplants were admitted to our institution because of persistent hypertension and impairment of transplant renal function and underwent angiography for vascular investigation. 27 were diagnosed suffering from transplant renal artery stenosis (TRAS, whereas 4 had severe iliac artery stenosis proximal to the transplant anastomosis (Prox-TRAS. 3 cases of TRAS coexisted with segmental renal arterial stenosis, whereas 3 other cases of TRAS were caused by kinking and focal stenosis in the middle of the transplanted renal artery. Results. Angioplasty and stenting were successfully applied to all patients with iliac artery stenosis as well as to those with TRAS and segmental artery stenosis. Two of three patients with kinking were well treated with angioplasty and stenting, whereas one treated only with angioplasty necessitated surgery. No major procedure-related complications appeared, and the result was decrease of the serum creatinine level and of the blood pressure. Conclusions. PTA is the appropriate initial treatment of TRAS and close-TRAS, with low morbidity and mortality rates, achieving improvement of graft function and amelioration of hypertension.

  10. Permanent and temporary pacemaker implantation after orthotopic heart transplantation

    Directory of Open Access Journals (Sweden)

    Bacal Fernando

    2000-01-01

    Full Text Available PURPOSE:To determine the indication for and incidence and evolution of temporary and permanent pacemaker implantation in cardiac transplant recipients. METHODS: A retrospective review of 114 patients who underwent orthotopic heart transplantation InCor (Heart Institute USP BR between March 1985 and May 1993. We studied the incidence of and indication for temporary pacing, the relationship between pacing and rejection, the need for pemanent pacing and the clinical follow-up. RESULTS: Fourteen of 114 (12%heart transplant recipients required temporary pacing and 4 of 114 (3.5% patients required permanent pacing. The indication for temporary pacing was sinus node dysfunction in 11 patients (78.5% and atrioventricular (AV block in 3 patients (21.4%. The indication for permanent pacemaker implantation was sinus node dysfunction in 3 patients (75% and atrioventricular (AV block in 1 patient (25%. We observed rejection in 3 patients (21.4% who required temporary pacing and in 2 patients (50% who required permanent pacing. The previous use of amiodarone was observed in 10 patients (71.4% with temporary pacing. Seven of the 14 patients (50% died during follow-up. CONCLUSION: Sinus node dysfunction was the principal indication for temporary and permanent pacemaker implantation in cardiac transplant recipients. The need for pacing was related to worse prognosis after cardiac transplantation.

  11. Tracheal stenosis after treatment with metallic stent: a situation worse than the initial problem

    International Nuclear Information System (INIS)

    Barreto, Jaime; Mejia, Bibiana; Nino, Federico; Garavito, Carlos

    2008-01-01

    Stens are a tubular device for use in trachea, carina or main bronchus to provide a support and maintain the permeability of these structures. There are two groups: Metallic and Silicone stent. Either metallic and silicone stents has a special properties. Metallic stent are very attractive option due to relative easy in their placement. The accumulated experience in this therapy has allowed to recognize several complications to take into consideration mainly in patients with tracheal benign stenosis. FDA has recommended don't use metallic stents, covered and not covered in benign diseases. We report a case of a tracheal stenosis secondary to prolonged ortho tracheal intubation that required extensive interventions to control symptoms of central airway obstruction, between April and July of 2005.

  12. Repair for mitral stenosis due to pannus formation after Duran ring annuloplasty.

    Science.gov (United States)

    Song, Seunghwan; Cho, Seong Ho; Yang, Ji-Hyuk; Park, Pyo Won

    2010-12-01

    Mitral stenosis after mitral repair with using an annuloplasty ring is not common and it is almost always due to pannus formation. Mitral valve replacement was required in most of the previous cases of pannus covering the mitral valve leaflet, which could not be stripped off without damaging the valve leaflets. In two cases, we removed the previous annuloplasty ring and pannus without leaflet injury, and we successfully repaired the mitral valve. During the follow-up of 4 months and 39 months respectively, we observed improvement of the patients' symptoms and good valvular function. Redo mitral repair may be a possible method for treating mitral stenosis due to pannus formation after ring annuloplasty. Copyright © 2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Computed tomography in lumbar canal stenosis

    International Nuclear Information System (INIS)

    Ohta, Shu; Baba, Itsushi; Ishida, Akihisa; Sumida, Tadayuki; Sasaki, Seishu

    1984-01-01

    Preoperative CT was done in 39 patients with lumbar canal stenosis. Marked symmetrical narrowing of the whole vertebral canal was seen in the group with nervous symptoms in the cauda equina. Deformed bilateral intervertebral joints were seen in the group with both nervous symptoms in the cauda equina and radicular sciatica. The lateral recess on the affected side was markedly narrowed by the projection of the upper and lower joints and herniation. In the group with radicular sciatica, the vertebral canal itself was not so narrowed, but the unilateral intervertebral joint was extremely deformed, causing a narrowing of the lateral recess. There were large differences in the angle of the left and right intervertebral joints. (Namekawa, K)

  14. Benign bile duct stenosis: diagnosis and treatment

    International Nuclear Information System (INIS)

    Garcia-Medina, J.; Casal, M.; Vieito, X.

    1997-01-01

    The bening injuries of the biliary ducts are relatively little frequent. Exist two groups of injuries: to due to them to a series for responsible pathologies for itself of the such injuries training, and that basically are the sclerosant cholangitis, the chronic pancreatitis and the stenosis of the sfinter of Oddi, and related them to previous surgery. On both groups eitological, the interventional radiology occupies a place in the diagnosis as well as in the treatment, complementing or substituting to the surgery. Due to the greater frequency of the postchirurgical injuries, we have centered us basically in them. We make a review of the current state of the topic and a bibliographical tracking, emphasizing the most relevant projects. We show some clinical cases of our subject-specific experience. (Author) 42 refs

  15. Noncardiac Surgery in Patients With Aortic Stenosis

    DEFF Research Database (Denmark)

    Andersson, Charlotte; Jørgensen, Mads Emil; Martinsson, Andreas

    2014-01-01

    (MACE) and all-cause mortality were investigated in a contemporary Danish cohort. HYPOTHESIS: AS is not an independent risk factor for adverse outcomes in noncardiac surgery. METHODS: All patients with and without diagnosed AS who underwent noncardiac surgery in 2005 to 2011 were identified through......BACKGROUND: Past research has identified aortic stenosis (AS) as a major risk factor for adverse outcomes in noncardiac surgery; however, more contemporary studies have questioned the grave prognosis. To further our understanding of this, the risks of a 30-day major adverse cardiovascular event...... nationwide administrative registers. AS patients (n = 2823; mean age, 75.5 years, 53% female) were matched with patients without AS (n = 2823) on propensity score for AS and surgery type. RESULTS: In elective surgery, MACE (ie, nonfatal myocardial infarction, ischemic stroke, or cardiovascular death...

  16. Cerebral oxygenation monitoring in patients with bilateral carotid stenosis undergoing urgent cardiac surgery: Observational case series

    Directory of Open Access Journals (Sweden)

    Dincer Aktuerk

    2016-01-01

    Full Text Available Background: Patients with significant bilateral carotid artery stenosis requiring urgent cardiac surgery have an increased risk of stroke and death. The optimal management strategy remains inconclusive, and the available evidence does not support the superiority of one strategy over another. Materials and Methods: A number of noninvasive strategies have been developed for minimizing perioperative stroke including continuous real-time monitoring of cerebral oxygenation with near-infrared spectroscopy (NIRS. The number of patients presenting with this combination (bilateral significant carotid stenosis requiring urgent cardiac surgery in any single institution will be small and hence there is a lack of large randomized studies. Results: This case series describes our early experience with NIRS in a select group of patients with significant bilateral carotid stenosis undergoing urgent cardiac surgery (n = 8. In contrast to other studies, this series is a single surgeon, single center study, where the entire surgery (both distal ends and proximal ends was performed during single aortic clamp technique, which effectively removes several confounding variables. NIRS monitoring led to the early recognition of decreased cerebral oxygenation, and corrective steps (increased cardiopulmonary bypass flow, increased pCO 2 , etc., were taken. Conclusion: The study shows good clinical outcome with the use of NIRS. This is our "work in progress," and we aim to conduct a larger study.

  17. High performance permanent magnet materials

    International Nuclear Information System (INIS)

    Sankar, S.G.; Herbst, J.F.; Koon, N.C.

    1987-01-01

    This book contains 25 selections. Some of the titles are: Initial magnetization behavior of rapidly quenched neodymium-iron-boron magnets; Optimization of liquid dynamic compaction for Fe-Nd-B magnet alloys; Misch-metal and/or aluminum substitutions in Nd-Fe-B permanent magnets; and NdFeB magnets with improved temperature characteristics

  18. OAS :: Member States : Permanent Representatives

    Science.gov (United States)

    Rights Actions against Corruption C Children Civil Registry Civil Society Contact Us Culture Cyber Barbados Belize Bolivia Brazil Canada Chile Colombia Costa Rica Cuba 1 Dominica (Commonwealth of) Dominican Gutierez Ambassador, Permanent Representative of Belize Diego Pary Rodríguez Bolivia Diego Pary Rodríguez

  19. Plaque Characteristics of Patients with Symptomatic Mild Carotid Artery Stenosis.

    Science.gov (United States)

    Takai, Hiroki; Uemura, Juniti; Yagita, Yoshiki; Ogawa, Yukari; Kinoshita, Keita; Hirai, Satoshi; Ishihara, Manabu; Hara, Keijirou; Toi, Hiroyuki; Matsubara, Shunji; Nishimura, Hirotake; Uno, Masaaki

    2018-03-20

    Carotid revascularization may be considered for severe stenosis, but its use for symptomatic mild stenosis (<50%) with vulnerable plaque or ulcer remains uncertain. The characteristics of patients with symptomatic mild stenosis who underwent revascularization are reviewed. The subjects of this study were 18 patients with symptomatic mild stenosis (<50%) on angiography from among 175 patients who underwent revascularization in our department. The plaques were evaluated by black-blood magnetic resonance imaging (BB-MRI) and ultrasonography (US) and classified into 2 types: type 1 (n = 15), a lesion with an ulcer or mobile plaque or thrombosis on angiography or US; and type 2 (n = 3), a lesion without any of the above. Fourteen patients underwent carotid endarterectomy (CEA), and 4 patients underwent carotid artery stenting. The stenosis on angiography was 27.2% ± 10.7 (5%-41%), and the area carotid artery stenosis rate on US was 69.8 ± 14.5% (44.5%-97%). The stenosis rate of these 2 methods was not at all correlated. In type 1 plaque that underwent CEA, 10 of 11 patients had vulnerable plaque by histopathology, and 1 patient had thrombus on the plaque by operative findings. In type 2 plaque that underwent CEA, all patients had vulnerable plaque by histopathology. During the follow-up period, none of the patients had restenosis or stroke. The findings of US and BB-MRI in patients with symptomatic mild stenosis (<50%) on angiography are important for determining treatment. If BB-MRI or US shows the findings of vulnerable plaque in mild stenosis, surgical treatment may be considered for these patients. Copyright © 2018 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  20. Phenotyping of lumbosacral stenosis in Labrador retrievers using computed tomography.

    Science.gov (United States)

    Mukherjee, Meenakshi; Jones, Jeryl C; Holásková, Ida; Raylman, Raymond; Meade, Jean

    2017-09-01

    Deep phenotyping tools for characterizing preclinical morphological conditions are important for supporting genetic research studies. Objectives of this retrospective, cross-sectional, methods comparison study were to describe and compare qualitative and quantitative deep phenotypic characteristics of lumbosacral stenosis in Labrador retrievers using computed tomography (CT). Lumbosacral CT scans and medical records were retrieved from data archives at three veterinary hospitals. Using previously published qualitative CT diagnostic criteria, a board-certified veterinary radiologist assigned dogs as either lumbosacral stenosis positive or lumbosacral stenosis negative at six vertebral locations. A second observer independently measured vertebral canal area, vertebral fat area, and vertebral body area; and calculated ratios of vertebral canal area/vertebral body area and vertebral fat area/vertebral body area (fat area ratio) at all six locations. Twenty-five dogs were sampled (lumbosacral stenosis negative, 11 dogs; lumbosacral stenosis positive, 14 dogs). Of the six locations, cranial L6 was the most affected by lumbosacral stenosis (33%). Five of six dogs (83%) with clinical signs of lumbosacral pain were lumbosacral stenosis positive at two or more levels. All four quantitative variables were significantly smaller at the cranial aspects of the L6 and L7 vertebral foramina than at the caudal aspects (P stenosis positive status at all six locations with cranial L6 having the greatest predictive value (R 2 = 0.43) and range of predictive probability (25-90%). Findings from the current study supported the use of CT as a deep phenotyping tool for future research studies of lumbosacral stenosis in Labrador retrievers. © 2017 American College of Veterinary Radiology.

  1. Paradoxical aortic stenosis: A systematic review.

    Science.gov (United States)

    Cavaca, Rita; Teixeira, Rogério; Vieira, Maria João; Gonçalves, Lino

    2017-04-01

    Aortic stenosis (AS) is a complex systemic valvular and vascular disease with a high prevalence in developed countries. The new entity "paradoxical low-flow, low-gradient aortic stenosis" refers to cases in which patients have severe AS based on assessment of aortic valve area (AVA) (≤1 cm 2 ) or indexed AVA (≤0.6 cm 2 /m 2 ), but paradoxically have a low mean transvalvular gradient (<40 mmHg) and a low stroke volume index (≤35 ml/m 2 ), despite preserved left ventricular ejection fraction (≥50%). A search was carried out in the PubMed database on paradoxical AS for the period 2007-2014. A total of 57 articles were included for this review. The prevalence of paradoxical AS ranged from 3% to 35% of the population with severe degenerative AS. It was more frequent in females and in older patients. Paradoxical AS was associated with characteristic left ventricular remodeling as well as an increase in systemic arterial stiffness. It was noted that there may be errors and inaccuracies in the calculation of AVA by the continuity equation, which could erroneously suggest the paradoxical phenotype. There are new diagnostic methods to facilitate the study of AS, such as aortic valve calcium score, valvuloarterial impedance and the longitudinal mechanics of the left ventricle. With regard to its natural history, it is not clear whether paradoxical AS corresponds to an advance stage of the disease or if paradoxical AS patients have a distinct phenotype with specific characteristics. Valve replacement, either surgical or percutaneous, may be indicated in patients with severe and symptomatic paradoxical AS. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Relationship of cerebral arterial stenosis to cognitive and memory disorders

    Institute of Scientific and Technical Information of China (English)

    Jifeng Li; Zhou Wang; Shenggang Sun; Gaomei Cai; Kejin Gu; Yaoqun Li

    2006-01-01

    BACKGROUND: Cerebral arterial stenosis can cause cerebral hypoperfusion, and than result in the decline of cognitive function, whereas the cognitive dysfunction induced by different cerebral arterial stenosis have different manifestations and types.OBJECTIVE: To observe the differences of cognitive and memory dysfunctions in patients with cerebral arterial stenosis of different types.DESIGN: A comparative observation.SETTING: Affiliated Hospital of Jining Medical College.PARTICIPANTS: Forty-two outpatients or inpatients with cerebral arterial stenosis were selected from the Department of Neurology, Affiliated Hospital of Jining Medical College from February 2005 to January 2006,including 25 males and 17 females. There were 18 cases of internal carotid arterial stenosis, 14 cases of vertebrobasilar arterial stenosis and 10 cases of whole cerebral arterial stenosis. The diagnostic standards for cerebral arterial stenosis were identified according to North American Symptomatic Carotid Endarterectomy Trial (NAS CET). Meanwhile, 18 healthy physical examinees were enrolled as the control group, including 10males and 8 females, aged 58-80 years old. All the enrolled subjects were informed and agreed with the detection and evaluation.METHODS: ① The memory function was evaluated using revised Wechsler memory scale for adults, including long-term memory (experience, orientation and counting), short-term memory (visual recognition, picture memory, visual regeneration, association and thigmesthesia) and sensory memory (forward and backward recitation of numbers). The scale scores were turned to memory quotients. The higher the scores, the better the memory function. ② The cognitive function was evaluated using revised Wechsler adult intelligence scale:It consisted of eleven subtests, including six language scales (information, digit span, vocabulary, arithmetics,apprehension, similarity) and five operation scales (picture completion, picture arrangement, block design

  3. Ultrasonographic analysis versus histopathologic evaluation of carotid advanced atherosclerotic stenosis in an experimental rabbit model.

    Science.gov (United States)

    Mehrad, Hossein; Mokhtari-Dizaji, Manijhe; Ghanaati, Hossein; Shahbazfar, Amir-Ali; Salehnia, Mojdeh

    2012-08-01

    Advanced carotid atherosclerosis with severe stenosis (>70%) is a major clinical risk factor for ischemic stroke. Our ability to test new protocols for the treatment of atherosclerotic stenosis in humans is limited for obvious ethical reasons; therefore, a suitable animal model is required. The aim of this study was to generate an easily reproducible and inexpensive experimental rabbit carotid model of advanced atherosclerosis with morphological similarities to the human disease and the subsequent assessment of the reliability of B-mode ultrasound technology in the study of lumen area stenosis in this model. Briefly, New Zealand white rabbits underwent primary perivascular cold injury at the right common carotid artery followed by a 1.5% cholesterol-rich diet injury for eight weeks. All of the rabbits' arteries were imaged by B-mode ultrasound weekly, after which the rabbits were sacrificed, and their vessels were processed for histopathology. Ultrasound longitudinal view images from three cardiac cycles were processed by a new computerized analyzing method based on dynamic programming and maximum gradient algorithm for measurement of instantaneous changes in arterial wall thickness and lumen diameter in sequential ultrasound images. Histopathology results showed progressive changes, from the lipid-laden cells and fibrous connective tissue proliferation in neointimal layer, up to the fibro-lipid plaque formation, resulting in vessel wall thickening, remodeling and lumen stenosis. The B-mode ultrasound images and the histologic measurements showed an increase in the mean wall thickness and the lumen area stenosis within eight weeks. Quantitative and morphometric analysis of the mean wall thickness and the lumen area stenosis percentage showed a significant correlation between the B-mode ultrasound and the histological measurements at each time point (R = 0.989 and R = 0.995, p < 0.05, respectively). In conclusion, we successfully produced advanced atherosclerosis in

  4. frequency of severe mitral stenosis in young female patients having pure mitral stenosis secondary to rheumatic heart disease

    International Nuclear Information System (INIS)

    Ahmad, S.; Hayat, U.; Naz, H.

    2010-01-01

    High morbidity and mortality due to Rheumatic heart disease (RHD) associated with females is mainly because of late diagnosis on one hand and socioeconomic reasons on the other hand. Poor referral to tertiary care centres leads to delayed diagnosis which results in complications. The objectives of this cross-sectional descriptive study was to assess the frequency of severe mitral stenosis in woman of child bearing age, having pure mitral stenosis (MS) secondary to rheumatic heart disease. Methods: Two hundred and fifty women of child bearing age with RHD were enrolled in the study using consecutive non-probability sampling technique. Out of these 250 patients, cases of pure MS were selected. Patients with associated mitral regurgitation and aortic valve disease were excluded. After admission, assessment of mitral valve stenosis was done with 2D colour Doppler echocardiography. Results: Out of 250 consecutive patients of rheumatic carditis, 110 (44%) patients had pure mitral valve stenosis, 85 (34%) had stenosis with mitral regurgitation and 55 (22%) patients had both mitral and aortic valve problem of varying severity. Among 110 patients with pure mitral valve stenosis, 48 (43.6%) had severe mitral valve stenosis. Severe mitral valve gradient (MVG) and high pulmonary artery pressure (PAP) was observed in 66 (60%) and 49 (44.5%) of the patients respectively. Conclusion: This high frequency can be linked to lack of early detection of the disease at primary level, poor management of throat infections and poor rheumatic fever prophylaxis at community level. (author )

  5. Balloon catheter dilation of benign esophageal stenosis in children

    International Nuclear Information System (INIS)

    Fan Guoping; Yu Juming; Zhong Weixing; Zhu Ming; Wu Yeming; Shi Chengren

    2001-01-01

    Objective: To evaluate the methods and effect of balloon catheter dilation of benign esophageal stenosis in children. Methods: 9 cases had an anastomotic stenosis after surgical correction of esophageal atresia; 11 cases of esophageal stenosis due to ingestion of caustics; one case had an lower esophageal stenosis after Nissen surgery and one case after gastro-esophagoplasty. Age ranged from 17 days to 7 years. Each case had a barium esophagram before balloon dilation. The balloon size varied from 3 to 10 mm in diameter. Results: 21 cases were successful after dilation of balloon catheter. There were no esophageal perforation and complications. The satisfactory results maintained from six months to thirty months. Conclusions: Balloon catheter dilation is a simple, safe and reliable method for the treatment of benign esophageal strictures in children as the first choice

  6. Diagnosis and management of carotid stenosis: a review.

    Science.gov (United States)

    Nussbaum, E S

    2000-01-01

    Since its introduction in the 1950s, carotid endarterectomy has become one of the most frequently performed operations in the United States. The tremendous appeal of a procedure that decreases the risk of stroke, coupled with the large number of individuals in the general population with carotid stenosis, has contributed to its popularity. To provide optimal patient care, the practicing physician must have a firm understanding of the proper evaluation and management of carotid stenosis. Nevertheless, because of the large number of clinical trials performed over the last decade addressing the treatment of stroke and carotid endarterectomy, the care of patients with carotid stenosis remains a frequently misunderstood topic. This review summarizes the current evaluation and treatment options for carotid stenosis and provides a rational management algorithm for this prevalent disease process.

  7. Celiac artery stenosis/occlusion treated by interventional radiology

    International Nuclear Information System (INIS)

    Ikeda, Osamu; Tamura, Yoshitaka; Nakasone, Yutaka; Yamashita, Yasuyuki

    2009-01-01

    Severe stenosis/occlusion of the proximal celiac trunk due to median arcuate ligament compression (MALC), arteriosclerosis, pancreatitis, tumor invasion, and celiac axis agenesis has been reported. However, clinically significant ischemic bowel disease attributable to celiac axis stenosis/occlusion appears to be rare because the superior mesenteric artery (SMA) provides for rich collateral circulation. In patients with celiac axis stenosis/occlusion, the most important and frequently encountered collateral vessels from the SMA are the pancreaticoduodenal arcades. Patients with celiac artery stenosis/occlusion are treated by interventional radiology (IR) via dilation of the pancreaticoduodenal arcade. In patients with dilation of the pancreaticoduodenal arcade on SMA angiograms, IR through this artery may be successful. Here we provide several tips on surmounting these difficulties in IR including transcatheter arterial chemoembolization for hepatocellular carcinoma, an implantable port system for hepatic arterial infusion chemotherapy to treat metastatic liver tumors, coil embolization of pancreaticoduodenal artery aneurysms, and arterial stimulation test with venous sampling for insulinomas.

  8. Celiac artery stenosis/occlusion treated by interventional radiology

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Osamu [Department of Diagnostic Radiology, Kumamoto University Graduate School of Medical and Pharmaceutical Sciences, 1-1-1, Honjo Kumamoto 860-8505 (Japan)], E-mail: osamu-3643ik@do9.enjoy.ne.jp; Tamura, Yoshitaka; Nakasone, Yutaka; Yamashita, Yasuyuki [Department of Diagnostic Radiology, Kumamoto University Graduate School of Medical and Pharmaceutical Sciences, 1-1-1, Honjo Kumamoto 860-8505 (Japan)

    2009-08-15

    Severe stenosis/occlusion of the proximal celiac trunk due to median arcuate ligament compression (MALC), arteriosclerosis, pancreatitis, tumor invasion, and celiac axis agenesis has been reported. However, clinically significant ischemic bowel disease attributable to celiac axis stenosis/occlusion appears to be rare because the superior mesenteric artery (SMA) provides for rich collateral circulation. In patients with celiac axis stenosis/occlusion, the most important and frequently encountered collateral vessels from the SMA are the pancreaticoduodenal arcades. Patients with celiac artery stenosis/occlusion are treated by interventional radiology (IR) via dilation of the pancreaticoduodenal arcade. In patients with dilation of the pancreaticoduodenal arcade on SMA angiograms, IR through this artery may be successful. Here we provide several tips on surmounting these difficulties in IR including transcatheter arterial chemoembolization for hepatocellular carcinoma, an implantable port system for hepatic arterial infusion chemotherapy to treat metastatic liver tumors, coil embolization of pancreaticoduodenal artery aneurysms, and arterial stimulation test with venous sampling for insulinomas.

  9. Constructing canine carotid artery stenosis model by endovascular technique

    International Nuclear Information System (INIS)

    Cheng Guangsen; Liu Yizhi

    2005-01-01

    Objective: To establish a carotid artery stenosis model by endovascular technique suitable for neuro-interventional therapy. Methods: Twelve dogs were anesthetized, the unilateral segments of the carotid arteries' tunica media and intima were damaged by a corneous guiding wire of home made. Twenty-four carotid artery stenosis models were thus created. DSA examination was performed on postprocedural weeks 2, 4, 8, 10 to estimate the changes of those stenotic carotid arteries. Results: Twenty-four carotid artery stenosis models were successfully created in twelve dogs. Conclusions: Canine carotid artery stenosis models can be created with the endovascular method having variation of pathologic characters and hemodynamic changes similar to human being. It is useful for further research involving the new technique and new material for interventional treatment. (authors)

  10. Automated phenotyping of permanent crops

    Science.gov (United States)

    McPeek, K. Thomas; Steddom, Karl; Zamudio, Joseph; Pant, Paras; Mullenbach, Tyler

    2017-05-01

    AGERpoint is defining a new technology space for the growers' industry by introducing novel applications for sensor technology and data analysis to growers of permanent crops. Serving data to a state-of-the-art analytics engine from a cutting edge sensor platform, a new paradigm in precision agriculture is being developed that allows growers to understand the unique needs of each tree, bush or vine in their operation. Autonomous aerial and terrestrial vehicles equipped with multiple varieties of remote sensing technologies give AGERpoint the ability to measure key morphological and spectral features of permanent crops. This work demonstrates how such phenotypic measurements combined with machine learning algorithms can be used to determine the variety of crops (e.g., almond and pecan trees). This phenotypic and varietal information represents the first step in enabling growers with the ability to tailor their management practices to individual plants and maximize their economic productivity.

  11. Permanently calibrated interpolating time counter

    International Nuclear Information System (INIS)

    Jachna, Z; Szplet, R; Kwiatkowski, P; Różyc, K

    2015-01-01

    We propose a new architecture of an integrated time interval counter that provides its permanent calibration in the background. Time interval measurement and the calibration procedure are based on the use of a two-stage interpolation method and parallel processing of measurement and calibration data. The parallel processing is achieved by a doubling of two-stage interpolators in measurement channels of the counter, and by an appropriate extension of control logic. Such modification allows the updating of transfer characteristics of interpolators without the need to break a theoretically infinite measurement session. We describe the principle of permanent calibration, its implementation and influence on the quality of the counter. The precision of the presented counter is kept at a constant level (below 20 ps) despite significant changes in the ambient temperature (from −10 to 60 °C), which can cause a sevenfold decrease in the precision of the counter with a traditional calibration procedure. (paper)

  12. Renal artery stenosis after radiotherapy for Ewing's sarcoma

    International Nuclear Information System (INIS)

    Tacconi, S.; Bieri, S.

    2008-01-01

    Background: the fact that therapeutic irradiation can induce significant stenosis in the arteries of the head, neck, and chest, as welt as in the aorta and the iliac arteries, is familiar in daily practice and well documented in the literature. By contrast, radiation-induced renal artery stenosis seems to be a less widely known complication. Patients and methods: the sudden onset of medically refractory arterial hypertension and coma in a 27-year-old man is reported, who had been treated at age 20 with chemotherapy and radiotherapy for Ewing's sarcoma in the lumbar region. This treatment had been performed at the hospital of Sion, Switzerland in 2001. Also, the relevant literature from 1965 to 2007 is reviewed to underscore various aspects of this problem and to demonstrate the clinical relevance of renal artery stenosis as a potential long-term sequela of radiotherapy. Conclusion: radiation-induced renal artery stenosis has only rarely been described in the literature, but arterial hypertension due to radiation-induced renal artery stenosis is a serious long-term sequela that can appear at a latency of up to 20 years after treatment. The paucity of reports presumably reflects the lesser frequency of radiotherapy for retroperitoneal tumors as compared to head-and-neck cancers, as well as lower awareness of the problem due to diagnostic bias in the era before CT and MRI were in routine use: at that time, carotid artery stenosis was easy to diagnose by ultrasonography, while radiation-induced renal artery stenosis, whose real incidence may well be higher, probably often went undetected. Thus, when a patient with a history of abdominal or retroperitoneal radiotherapy unexpectedly develops intractable hypertension, radiation-induced renal artery stenosis must be included in the differential diagnosis. (orig.)

  13. Internal Carotid Artery Stenosis and Collateral Recruitment in Stroke Patients.

    Science.gov (United States)

    Dankbaar, Jan W; Kerckhoffs, Kelly G P; Horsch, Alexander D; van der Schaaf, Irene C; Kappelle, L Jaap; Velthuis, Birgitta K

    2017-04-24

    Leptomeningeal collaterals improve outcome in stroke patients. There is great individual variability in their extent. Internal carotid artery (ICA) stenosis may lead to more extensive recruitment of leptomeningeal collaterals. The purpose of this study was to evaluate the association of pre-existing ICA stenosis with leptomeningeal collateral filling visualized with computed tomography perfusion (CTP). From a prospective acute ischemic stroke cohort, patients were included with an M1 middle cerebral artery (MCA) occlusion and absent ipsilateral, extracranial ICA occlusion. ICA stenosis was determined on admission CT angiography (CTA). Leptomeningeal collaterals were graded as good (>50%) or poor (≤50%) collateral filling in the affected MCA territory on CTP-derived vessel images of the admission scan. The association between ipsilateral ICA stenosis ≥70% and extent of collateral filling was analyzed using logistic regression. In a multivariable analysis the odds ratio (OR) of ICA stenosis ≥70% was adjusted for complete circle of Willis, gender and age. We included 188 patients in our analyses, 50 (26.6%) patients were classified as having poor collateral filling and 138 (73.4%) as good. Of the patients 4 with poor collateral filling had an ICA stenosis ≥70% and 14 with good collateral filling. Unadjusted and adjusted ORs of ICA stenosis ≥70% for good collateral filling were 1.30 (0.41-4.15) and 2.67 (0.81-8.77), respectively. Patients with poor collateral filling had a significantly worse outcome (90-day modified Rankin scale 3-6; 80% versus 52%, p = 0.001). No association was found between pre-existing ICA stenosis and extent of CTP derived collateral filling in patients with an M1 occlusion.

  14. Diminutive Porcelain Ascending Aorta With Supravalvular Aortic Stenosis.

    Science.gov (United States)

    Houmsse, Mustafa; McDavid, Asia; Kilic, Ahmet

    2018-05-01

    This report describes the case of a 49-year-old man with a medical history significant for congenital aortic stenosis. The patient presented with progressive shortness of breath and decreased stamina and was found to have a concentric, diminutive porcelain ascending aorta with diffuse supravalvular aortic stenosis. We describe treatment with an aortic root augmentation and Bentall procedure using hypothermic circulatory arrest. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Hypertrophic pyloric stenosis: tips and tricks for ultrasound diagnosis

    OpenAIRE

    Costa Dias, Sílvia; Swinson, Sophie; Torrão, Helena; Gonçalves, Lígia; Kurochka, Svitlana; Vaz, Carlos Pina; Mendes, Vasco

    2012-01-01

    We describe a systematic approach to the ultrasound (US) examination of the antropyloric region in children. US is the modality of choice for the diagnosis of hypertrophic pyloric stenosis (HPS). The imaging features of the normal pylorus and the diagnostic findings in HPS are reviewed and illustrated in this pictorial essay. Common difficulties in performing the examination and tips to help overcome them will also be discussed. Main Messages • Hypertrophic Pyloric Stenosis is defined by thic...

  16. Adjusting parameters of aortic valve stenosis severity by body size

    DEFF Research Database (Denmark)

    Minners, Jan; Gohlke-Baerwolf, Christa; Kaufmann, Beat A

    2014-01-01

    stenosis (jet velocity ≥2.5 m/s) and related to outcomes in a second cohort of 1525 patients from the Simvastatin/Ezetimibe in Aortic Stenosis (SEAS) study. RESULTS: Whereas jet velocity and MPG were independent of body size, AVA was significantly correlated with height, weight, BSA and BMI (Pearson...... correlation coefficient (r) 0.319, 0.281, 0.317 and 0.126, respectively, all pcorrelation between AVA and body size...

  17. Diagnosis of Lumbar Foraminal Stenosis using Diffusion Tensor Imaging

    OpenAIRE

    Eguchi, Yawara; Ohtori, Seiji; Suzuki, Munetaka; Oikawa, Yasuhiro; Yamanaka, Hajime; Tamai, Hiroshi; Kobayashi, Tatsuya; Orita, Sumihisa; Yamauchi, Kazuyo; Suzuki, Miyako; Aoki, Yasuchika; Watanabe, Atsuya; Kanamoto, Hirohito; Takahashi, Kazuhisa

    2016-01-01

    Diagnosis of lumbar foraminal stenosis remains difficult. Here, we report on a case in which bilateral lumbar foraminal stenosis was difficult to diagnose, and in which diffusion tensor imaging (DTI) was useful. The patient was a 52-year-old woman with low back pain and pain in both legs that was dominant on the right. Right lumbosacral nerve compression due to a massive uterine myoma was apparent, but the leg pain continued after a myomectomy was performed. No abnormalities were observed dur...

  18. Predictors of exercise capacity and symptoms in severe aortic stenosis

    DEFF Research Database (Denmark)

    Dalsgaard, Morten; Kjaergaard, Jesper; Pecini, Redi

    2010-01-01

    This study investigated the association between invasive and non-invasive estimates of left ventricular (LV) filling pressure and exercise capacity, in order to find new potential candidates for risk markers in severe aortic valve stenosis (AS).......This study investigated the association between invasive and non-invasive estimates of left ventricular (LV) filling pressure and exercise capacity, in order to find new potential candidates for risk markers in severe aortic valve stenosis (AS)....

  19. Craniovertebral junction stenosis in Lenz-Majewski syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Mizuguchi, Koichi; Ishigro, Akira [National Center for Child Health and Development, Department of General Pediatrics and Interdisciplinary Medicine, Setagaya-ku, Tokyo (Japan); Miyazaki, Osamu [National Center for Child Health and Development, Department of Radiology, Tokyo (Japan); Nishimura, Gen [Tokyo Metropolitan Children' s Medical Center, Department of Pediatric Imaging, Tokyo (Japan)

    2015-09-15

    We report a girl with Lenz-Majewski syndrome associated with craniovertebral junction stenosis that led to communicating hydrocephalus and cervical myelopathy. The life-threatening complication was related to progressive craniovertebral hyperostosis that rapidly exacerbated during early childhood. Despite initial success of surgical intervention at 2 years of age, she developed apneic spells and died suddenly at age 5 years. Close monitoring for craniovertebral junction stenosis is essential to reduce morbidity and mortality in children with Lenz-Majewski syndrome. (orig.)

  20. Fully Covered Metallic Stents for the Treatment of Benign Airway Stenosis

    Directory of Open Access Journals (Sweden)

    Caroline Dahlqvist

    2016-01-01

    Full Text Available Introduction. We herein report our experience with new fully covered self-expanding metallic stents in the setting of inoperable recurrent benign tracheobronchial stenosis. Methods. Between May 2010 and July 2014, 21 Micro-Tech® FC-SEMS (Nanjing Co., Republic of Korea were placed in our hospital in 16 patients for inoperable, recurrent (after dilatation, and symptomatic benign airway stenosis. Their medical files were retrospectively reviewed in December 2014, with focus on stent’s tolerance and durability data. Results. Twenty-one stents were inserted: 13 for posttransplant left main bronchus anastomotic stricture, seven for postintubation tracheal stenosis, and one for postlobectomy anastomotic stricture. Positioning was easy for all of them. Stents were in place for a mean duration of 282 days. The most common complications were granulation tissue development (35%, migration (30%, and sputum retention (15%. Fifty-five % of the stents (11/20 had to be removed because of various complications, without difficulty for all of them. None of the patients had life-threatening complications. Conclusion. Micro-Tech FC-SEMS were easy to position and to remove. While the rate of complications requiring stent removal was significant, no life-threatening complication occurred. Further studies are needed to better define their efficacy and safety in the treatment of benign airway disease.

  1. Fully Covered Metallic Stents for the Treatment of Benign Airway Stenosis.

    Science.gov (United States)

    Dahlqvist, Caroline; Ocak, Sebahat; Gourdin, Maximilien; Dincq, Anne Sophie; Putz, Laurie; d'Odémont, Jean-Paul

    2016-01-01

    Introduction. We herein report our experience with new fully covered self-expanding metallic stents in the setting of inoperable recurrent benign tracheobronchial stenosis. Methods. Between May 2010 and July 2014, 21 Micro-Tech® FC-SEMS (Nanjing Co., Republic of Korea) were placed in our hospital in 16 patients for inoperable, recurrent (after dilatation), and symptomatic benign airway stenosis. Their medical files were retrospectively reviewed in December 2014, with focus on stent's tolerance and durability data. Results. Twenty-one stents were inserted: 13 for posttransplant left main bronchus anastomotic stricture, seven for postintubation tracheal stenosis, and one for postlobectomy anastomotic stricture. Positioning was easy for all of them. Stents were in place for a mean duration of 282 days. The most common complications were granulation tissue development (35%), migration (30%), and sputum retention (15%). Fifty-five % of the stents (11/20) had to be removed because of various complications, without difficulty for all of them. None of the patients had life-threatening complications. Conclusion. Micro-Tech FC-SEMS were easy to position and to remove. While the rate of complications requiring stent removal was significant, no life-threatening complication occurred. Further studies are needed to better define their efficacy and safety in the treatment of benign airway disease.

  2. Is there a correlation between sleep disordered breathing and foramen magnum stenosis in children with achondroplasia?

    Science.gov (United States)

    White, Klane K; Parnell, Shawn E; Kifle, Yemiserach; Blackledge, Marcella; Bompadre, Viviana

    2016-01-01

    Children with achondroplasia have midface hypoplasia, frontal bossing, spinal stenosis, rhizomelia, and a small foramen magnum. Central sleep apnea, with potential resultant sudden death, is thought to be related to compression of the spinal cord at the cervicomedullary junction in these patients. Screening polysomnography and/or cervical spine MRI are often performed for infants with achondroplasia. Decompressive suboccipital craniectomy has been performed in selected cases. We aim to better delineate the relationship between polysomnography, cervical spine MRI, and indications for surgical decompression in achondroplasia.We retrospectively review electronic medical records of all children with achondroplasia in our IRB-approved skeletal dysplasia registry who had received screening polysomnography and cervical spine MRI examination was performed. We explored correlations of polysomnography, MRI parameters, and need for decompressive surgery. Seventeen patients with both polysomnography and MRI of the cervical spine met inclusion criteria. The average age at time of the sleep study was 2.4 ± 3.6 years. An abnormal apnea-hypopnea index was found in all patients, with central sleep apnea found in 6/17. Five patients (29%) required foramen magnum decompression. We found no statistically significant correlation between central sleep apnea and abnormal MRI findings suggestive of foramen magnum stenosis. Screening polysomnography is an important tool but does not appear to correlate with MRI findings of foramen magnum stenosis. Cord compression, with either associated T2 cord signal abnormality or clinical findings of clonus, was most predictive of subsequent surgical decompression. © 2015 Wiley Periodicals, Inc.

  3. Spastic quadriplegia in Down syndrome with congenital duodenal stenosis/atresia.

    Science.gov (United States)

    Kurosawa, Kenji; Enomoto, Keisuke; Tominaga, Makiko; Furuya, Noritaka; Sameshima, Kiyoko; Iai, Mizue; Take, Hiroshi; Shinkai, Masato; Ishikawa, Hiroshi; Yamanaka, Michiko; Matsui, Kiyoshi; Masuno, Mitsuo

    2012-06-01

    Down syndrome is an autosomal chromosome disorder, characterized by intellectual disability and muscle hypotonia. Muscle hypotonia is observed from neonates to adulthood in Down syndrome patients, but muscle hypertonicity is extremely unusual in this syndrome. During a study period of nine years, we found three patients with severe spastic quadriplegia among 20 cases with Down syndrome and congenital duodenal stenosis/atresia (3/20). However, we could find no patient with spastic quadriplegia among 644 cases with Down syndrome without congenital duodenal stenosis/atresia during the same period (0/644, P quadriplegia among 17 patients with congenital duodenal stenosis/atresia without Down syndrome admitted during the same period to use as a control group (0/17, P quadriplegia in patients with Down syndrome. Long-term survival is improving, and the large majority of people with Down syndrome are expected to live well into adult life. Management and further study for the various problems, representing a low prevalence but serious and specific to patients with Down syndrome, are required to improve their quality of life. © 2012 The Authors. Congenital Anomalies © 2012 Japanese Teratology Society.

  4. Effect of lipid-lowering therapy on the progression of intracranial arterial stenosis.

    Science.gov (United States)

    Tan, Teng-Yeow; Kuo, Yeh-Lin; Lin, Wei-Che; Chen, Ting-Yao

    2009-02-01

    Intracranial arterial stenosis (IAS) is a severe disease with a high recurrent stroke rate even under the best medical treatment. Statins have been demonstrated to prevent stroke and to slow or halt atherosclerosis progression. This study was performed to observe the effect of atorvastatin on the progression of IAS, explore the factors associated with atherosclerosis regression and the recurrent rate of stroke. A hospital-base observation study enrolled 40 stroke patients with middle cerebral artery (MCA) or/and basilar artery (BA) stenosis. All participants had hyperlipidemia and were given atorvastatin 40 mg per day for at least six months. IAS was assessed by magnetic resonance angiogram (MRA) at the time of enrollment and then at least six months later. The primary outcome was the progression of IAS. All patients were also given antiplatelet agents for stroke prevention. At the end of the study, 23 (58 %), 15 (38 %) and 2 (4 %) patients had regressed, stationary and progressed IAS, respectively. Females were likely to have regressed IAS. The recurrent stroke rate was 18 %. Among the 54 stenotic vessels, 29 (54 %) vessels were assessed as improvement in stenosis. Compared with other studies, more regressed, stationary IAS and less progressed IAS were found in our study. Female gender was likely to have regressed IAS after statin treatment. Further clinical outcome trials are required to assess the effects of such therapy on morbidity and mortality in this particular group of patients.

  5. The cycloid Permanent Magnetic Gear

    DEFF Research Database (Denmark)

    Rasmussen, Peter Omand; Andersen, Torben Ole; Jørgensen, Frank T.

    2008-01-01

    This paper presents a new permanent-magnet gear based on the cycloid gearing principle. which normally is characterized by an extreme torque density and a very high gearing ratio. An initial design of the proposed magnetic gear was designed, analyzed, and optimized with an analytical model...... regarding torque density. The results were promising as compared to other high-performance magnetic-gear designs. A test model was constructed to verify the analytical model....

  6. Special-Purpose High-Torque Permanent-Magnet Motors

    Science.gov (United States)

    Doane, George B., III

    1995-01-01

    Permanent-magnet brushless motors that must provide high commanded torques and satisfy unusual heat-removal requirement are developed. Intended for use as thrust-vector-control actuators in large rocket engines. Techniques and concepts used to design improved motors for special terrestrial applications. Conceptual motor design calls for use of rotor containing latest high-energy-product rare-earth permanent magnets so that motor produces required torque while drawing smallest possible currents from power supply. Torque generated by electromagnetic interaction between stator and permanent magnets in rotor when associated electronic circuits applied appropriately temporally and spatially phased currents to stator windings. Phase relationships needed to produce commanded torque computed in response to torque command and to electronically sensed angular position of rotor relative to stator.

  7. A Comparison of Stent Implant versus Medical Treatment for Severe Symptomatic Intracranial Stenosis: A Controlled Clinical Trial

    Directory of Open Access Journals (Sweden)

    Rezao Mohammadian

    2012-11-01

    stent implant group had significantly better favorable functional outcomes according to the mRS than the medical group (93.9 vs. 63.0%. The cumulative secondary adverse event-free survival was significantly lower in the stent implant group. Conclusion: Stent implants can be considered more durable and safe for patients with symptomatic severe stenosis of the internal carotid artery or middle cerebral artery, despite optimal medical therapy. Randomized, multicenter trials are required to confirm these results.

  8. Visual and quantitative assessment of lateral lumbar spinal canal stenosis with magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sipola, Petri; Vanninen, Ritva; Manninen, Hannu (Univ. of Eastern Finland, Faculty of Health Sciences, School of Medicine, Inst. of Clinical Medicine, Dept. of Clinical Radiology, Kuopio (Finland); Kuopio Univ. Hospital, Clinical Imaging Centre, Dept. of Clinical Radiology, Kuopio (Finland)), email: petri.sipola@kuh.fi; Leinonen, Ville (Kuopio Univ. Hospital, Dept. of Neurosurgery, Kuopio (Finland)); Niemelaeinen, Riikka (Kuopio Univ. Hospital, Clinical Imaging Centre, Dept. of Clinical Radiology, Kuopio (Finland); Faculty of Rehabilitation Medicine, Univ. of Alberta, Edmonton, Alberta (Canada)); Aalto, Timo (Kyyhkylae Rehabilitation Center and Hospital, Mikkeli (Finland)); Airaksinen, Olavi (Kuopio Univ. Hospital, Dept. of Physical and Rehabilitation Medicine and Univ. of Eastern Finland, Faculty of Health Sciences, School of Medicine, Inst. of Clinical Medicine, Kuopio (Finland)); Battie, Michele C. (Faculty of Rehabilitation Medicine, Univ. of Alberta, Edmonton, Alberta (Canada))

    2011-11-15

    Background. Lateral lumbar spinal canal stenosis is a common etiology of lumbar radicular symptoms. Quantitative measurements have commonly demonstrated better repeatability than visual assessments. We are not aware of any studies examining the repeatability of quantitative assessment of the lateral canal. Purpose. To evaluate the repeatability of visual assessments and newly developed quantitative measurements of lateral lumbar spinal canal stenosis using magnetic resonance imaging (MRI). Material and Methods. Twenty-eight patients with lateral lumbar spinal canal stenosis or prior spinal surgery with recurrent symptoms were imaged with MRI. A radiologist, a neurosurgeon and a spine research trainee graded visually and quantitatively subarticular (n = 188) and foraminal zones (n = 260) of the lateral spinal canal. Quantitative measurements included the minimal subarticular width and the cross-sectional area of the foramen. Results. The repeatability of visual assessment at the subarticular zone and foraminal zones between raters varied from 0.45-0.59 and 0.42-0.53, respectively. Similarly, the intraclass correlation coefficients for the quantitative measurements varied from 0.67-0.71 and 0.66-0.76, respectively. The intra-rater repeatability for the visual assessments of the subarticular and foraminal zones was 0.70 and 0.62, respectively, while the corresponding intraclass correlation coefficients for quantitative measurements were 0.83 and 0.81, respectively. Conclusion. Inter-rater repeatability of visual assessments of lateral stenosis is moderate, whereas quantitative measurements of both subarticular width and the cross-sectional area of the foramen have substantial reproducibility and may be particularly useful for longitudinal studies and research purposes. The clinical value of these parameters requires further study

  9. Decompressive laminectomy for lumbar stenosis: review of 65 consecutive cases from Tema, Ghana.

    Science.gov (United States)

    Andrews, N B; Lawson, H J; Darko, D

    2007-01-01

    There have been previous reports describing patients with lumbar stenosis (LS) in West Africa; however, to date no such report has been published from Ghana. To provide data on the pattern of lumbar stenosis and the effects of decompressive lumbar laminectomy (DLL) on the clinical course of LS in Tema. Sixty-five consecutive patients who underwent DLL for lumbar stenosis over between January 2001 and December 2004 had their medical records analyzed. The parameters of interest included demographics, pre and post surgical clinical status utilizing the modified low back pain clinical scoring system, operative procedure and complications. Sixty-five patients (36M, 29F) with a mean age of 51 years constituted the series. All had failed conservative treatment; each patient was operated on once at our institution. Eighty nine percent of the series presented with neurogenic claudication and accompanying motor and sensory deficits. Twenty-seven patients (41.5%) underwent bilateral DLL; the rest underwent unilateral DLL. The mean preoperative score for the series was 2.3; that for males 2.6, females 1.9 (p > 0.05). There was a significant difference between patients 60 years. The mean postoperative score for the series was 8.7. There was a significant difference between preoperative and postoperative scores of series. No mortality was recorded The complication rate was 15%. In Tema, decompressive lumbar laminectomy for lumbar stenosis achieves significant clinical improvement with attendant low morbidity and mortality rates in patients who have failed conservative treatment. Accompanying disc excision and or fusion are required in only a small minority of patients.

  10. Visual and quantitative assessment of lateral lumbar spinal canal stenosis with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sipola, Petri; Vanninen, Ritva; Manninen, Hannu; Leinonen, Ville; Niemelaeinen, Riikka; Aalto, Timo; Airaksinen, Olavi; Battie, Michele C.

    2011-01-01

    Background. Lateral lumbar spinal canal stenosis is a common etiology of lumbar radicular symptoms. Quantitative measurements have commonly demonstrated better repeatability than visual assessments. We are not aware of any studies examining the repeatability of quantitative assessment of the lateral canal. Purpose. To evaluate the repeatability of visual assessments and newly developed quantitative measurements of lateral lumbar spinal canal stenosis using magnetic resonance imaging (MRI). Material and Methods. Twenty-eight patients with lateral lumbar spinal canal stenosis or prior spinal surgery with recurrent symptoms were imaged with MRI. A radiologist, a neurosurgeon and a spine research trainee graded visually and quantitatively subarticular (n = 188) and foraminal zones (n = 260) of the lateral spinal canal. Quantitative measurements included the minimal subarticular width and the cross-sectional area of the foramen. Results. The repeatability of visual assessment at the subarticular zone and foraminal zones between raters varied from 0.45-0.59 and 0.42-0.53, respectively. Similarly, the intraclass correlation coefficients for the quantitative measurements varied from 0.67-0.71 and 0.66-0.76, respectively. The intra-rater repeatability for the visual assessments of the subarticular and foraminal zones was 0.70 and 0.62, respectively, while the corresponding intraclass correlation coefficients for quantitative measurements were 0.83 and 0.81, respectively. Conclusion. Inter-rater repeatability of visual assessments of lateral stenosis is moderate, whereas quantitative measurements of both subarticular width and the cross-sectional area of the foramen have substantial reproducibility and may be particularly useful for longitudinal studies and research purposes. The clinical value of these parameters requires further study

  11. The Effects of Fetuin-A Levels on Aortic Stenosis

    Directory of Open Access Journals (Sweden)

    Ahmet Tutuncu

    2016-07-01

    Full Text Available Aim: We aimed to investigate the relation between fetuin-A and calcific aortic stenosis in non diabetic patients whose renal function were normal. Material and Method: 26 patients followed for aortic stenosis by our cardiology clinic for outpatients and 25 voluntary healthy subjects were included in the study. The fetuin%u2013A levels were measured from the venous blood samples of the study population. All patients underwent transthorasic echocardiography, the aortic valvular area and left ventricular parameters of the patients were measured. Results: The average age of the patients in degenerative aortic stenosis group was significantly higher than the control group. The parameters related to aortic valve were naturally higher in patients with dejenerative aortic valve. There was no siginificant difference between two groups about fetuin-A levels. Further more there was no significant relation between fetuin-a levels and aortic stenosis severity. Discussion: In conclusion fetuin-A is a multifunctional glycoprotein that plays important role in systemic calcification inhibition and valvular calcification. Finally aortic stenosis is an active process and larger studies that investigate the relation between fetuin-a and the progression and prognosis of aortic stenosis are needed.

  12. Choanal stenosis: a rare complication of radiotherapy for nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Bonfils, P.; Preobrajenski, N. de; Florent, A.; Bensimon, J.L.

    2007-01-01

    Choanal stenosis is usually a congenital anomaly in children. Acquired choanal stenosis after radiotherapy for nasopharyngeal carcinoma is a very rare pathology; only two publications report seven cases in the literature. We describe the clinical history, preoperative evaluation, surgical treatment and outcome of a case of acquired choanal stenosis after radiotherapy. The patient, a 56-year-old woman, presented with a history of nasopharyngeal carcinoma (T2- NO-MO) one year before that had been successful treated with radiotherapy (68 Gy). At the end of radiotherapy, she complained of complete nasal obstruction, anosmia and hearing loss due to a bilateral serous otitis media. Bilateral complete choanal stenosis was confirmed by endoscopy and CT scan. Functional endoscopic surgery was performed, and nasal stents were left in place for 3 weeks. One year after, the patient have good airflow, and a patent nasopharynx without choanal stenosis. In conclusion, choanal stenosis is an unusual complication of radiotherapy that can be successfully treated with trans-nasal endoscopic resection. (authors)

  13. Balloon dilatation of nasopharyngeal stenosis in a dog.

    Science.gov (United States)

    Berent, Allyson C; Kinns, Jennifer; Weisse, Chick

    2006-08-01

    A dog was examined because of a 6-month history of upper airway stridor that began after postoperative regurgitation of gastric contents. Constant stridor was evident during inspiration and expiration, although it was worse during inspiration. The stridor was no longer evident when the dog's mouth was manually held open. Computed tomography, rhinoscopy, and fluoroscopy were used to confirm a diagnosis of nasopharyngeal stenosis. The dog was anesthetized, and balloon dilatation of the stenosis was performed. Prednisone was prescribed for 4 weeks after the procedure to decrease fibrous tissue formation. Although the dog was initially improved, signs recurred 3.5 weeks later, and balloon dilatation was repeated. This time, however, triamcinolone was injected into the area of stenosis at the end of the dilatation procedure. Two months later, although the dog did not have clinical signs of stridor, a third dilatation procedure was performed because mild stenosis was seen on follow-up computed tomographic images; again, triamcinolone was injected into the area of stenosis at the end of the dilatation procedure. Three and 6 months after the third dilatation procedure, the dog reportedly was clinically normal. Findings suggest that balloon dilatation may be an effective treatment for nasopharyngeal stenosis in dogs.

  14. Lawful Permanent Residents Fiscal Year 2011 Country

    Data.gov (United States)

    Department of Homeland Security — Lawful permanet residents (LPRs) are foreign nationals who have been gratned the right to reside permanently in the United States. LPRs are also known as 'permanent...

  15. Permanent deformation and deflection relationship from pavement condition assessment

    Directory of Open Access Journals (Sweden)

    Fabricio Leiva-Villacorta

    2017-07-01

    Full Text Available The development of permanent deformation in flexible pavements has been a research topic for several decades. Currently there are models included in the structural design of pavements that can predict this type of failure. However, the variables required for the prediction of this distress are complex or difficult to obtain in the field, making its application in pavement evaluation also difficult. Measurement of the deflection of pavement structures by means of non-destructive testing is a technique used to assess the condition of the pavement. This research study seeks to correlate data from deflections of the pavement surface with probable permanent deformation in time. In addition, prediction of the remaining life of the pavement structure using a specified criterion is also analyzed. In order to accomplish these objectives, data acquired from 4 different full scale accelerated pavement test tracks was used to develop a permanent deformation model as a function of deflection, load repetitions and pavement layer thickness. The developed model considered a time series model that incorporates an Auto-regressive parameter of order 1. The proposed model presents an advantage over currently available models because it reduces the required parameters to predict the permanent deformation and/or remaining life in the structure and because these variables can be easily found and updated in a pavement management system. Keywords: HVS, Permanent deformation, Deflections, APT, Time series, Instrumentation

  16. Undersedation is a risk factor for the development of subglottic stenosis in intubated children

    Directory of Open Access Journals (Sweden)

    Cláudia Schweiger

    2017-07-01

    Full Text Available Objective: To analyze the level of sedation in intubated children as a risk factor for the development of subglottic stenosis. Methods: All patients between 30 days and 5 years of age who required endotracheal intubation in the pediatric intensive care unit between 2013 and 2014 were included in this prospective study. They were monitored daily and COMFORT-B scores were obtained. Flexible fiber-optic laryngoscopy was performed within eight hours of extubation, and repeated seven to ten days later if the first examination showed moderate to severe laryngeal injuries. If these lesions persisted and/or if the child developed symptoms in the follow-up period, microlaryngoscopy under general anesthesia was performed to evaluate for subglottic stenosis. Results: The study included 36 children. Incidence of subglottic stenosis was 11.1%. Children with subglottic stenosis had a higher percentage of COMFORT-B scores between 23 and 30 (undersedated than those who did not develop subglottic stenosis (15.8% vs. 3.65%, p = 0.004. Conclusion: Children who developed subglottic stenosis were less sedated than children who did not develop subglottic stenosis. Resumo: Objetivo: Analisar o nível de sedação em crianças intubadas como um fator de risco para o desenvolvimento de estenose subglótica (ES. Métodos: Todos os pacientes entre 30 dias e 5 anos de idades que necessitaram de intubação endotraqueal na Unidade de Terapia Intensiva Pediátrica entre 2013 e 2014 foram incluídos neste estudo prospectivo. Eles foram monitorados diariamente e foram obtidos os escores da escala COMFORT-B. Foi feita laringoscopia com tubo flexível de fibra óptica em 8 horas da extubação e repetida 7-10 dias depois, caso o primeiro exame tenha mostrado lesões laríngeas moderadas a graves. Caso essas lesões tenham persistido e/ou caso a criança tenha desenvolvido sintomas no período de acompanhamento, foi feita microlaringoscopia sob anestesia geral para avaliar a ES

  17. Teaching Object Permanence: An Action Research Study

    Science.gov (United States)

    Bruce, Susan M.; Vargas, Claudia

    2013-01-01

    "Object permanence," also known as "object concept" in the field of visual impairment, is one of the most important early developmental milestones. The achievement of object permanence is associated with the onset of representational thought and language. Object permanence is important to orientation, including the recognition of landmarks.…

  18. 21 CFR 886.4445 - Permanent magnet.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Permanent magnet. 886.4445 Section 886.4445 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4445 Permanent magnet. (a) Identification. A permanent magnet is a nonelectric device that generates a magnetic field intended to find and remove metallic...

  19. Echoguided closed commissurotomy for mitral valve stenosis in a dog.

    Science.gov (United States)

    Trehiou-Sechi, Emilie; Behr, Luc; Chetboul, Valérie; Pouchelon, Jean-Louis; Castaignet, Maud; Gouni, Vassiliki; Misbach, Charlotte; Petit, Amandine M P; Borenstein, Nicolas

    2011-09-01

    Surgical treatment of mitral stenosis (MS) usually consists of open mitral commissurotomy (MC) or percutaneous balloon MC, which require a cardiopulmonary bypass or transseptal approach, respectively. We describe here the first surgical management of congenital MS in a dog using a less invasive procedure, a surgical closed MC under direct echo guidance. A 5-year-old female Cairn terrier was referred for ascites, weakness, and marked exercise intolerance for 2 months, which was refractory to medical treatment. Diagnosis of severe MS associated with atrial fibrillation (AF) was confirmed by echo-Doppler examination and electrocardiography. Poor response to medical treatment suggested a corrective procedure on the valve was indicated. However, due to the cost and high mortality rate associated with cardiopulmonary bypass, a hybrid MC was recommended. A standard left intercostal thoracotomy was performed and three balloon valvuloplasty catheters of differing diameters were sequentially inserted through the left atrium under direct echo guidance. Transesophageal echocardiography revealed a 62% reduction in the pressure half-time compared to the pre-procedure. Thirteen months after surgery the dog is still doing well with resolution of ascites and a marked improvement of most echo-Doppler variables. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Aortic stenosis and vascular calcifications in alkaptonuria.

    Science.gov (United States)

    Hannoush, Hwaida; Introne, Wendy J; Chen, Marcus Y; Lee, Sook-Jin; O'Brien, Kevin; Suwannarat, Pim; Kayser, Michael A; Gahl, William A; Sachdev, Vandana

    2012-02-01

    Alkaptonuria is a rare metabolic disorder of tyrosine catabolism in which homogentisic acid (HGA) accumulates and is deposited throughout the spine, large joints, cardiovascular system, and various tissues throughout the body. In the cardiovascular system, pigment deposition has been described in the heart valves, endocardium, pericardium, aortic intima and coronary arteries. The prevalence of cardiovascular disease in patients with alkaptonuria varies in previous reports. We present a series of 76 consecutive adult patients with alkaptonuria who underwent transthoracic echocardiography between 2000 and 2009. A subgroup of 40 patients enrolled in a treatment study underwent non-contrast CT scans and these were assessed for vascular calcifications. Six of the 76 patients had aortic valve replacement. In the remaining 70 patients, 12 patients had aortic sclerosis and 7 patients had aortic stenosis. Unlike degenerative aortic valve disease, we found no correlation with standard cardiac risk factors. There was a modest association between the severity of aortic valve disease and joint involvement, however, we saw no correlation with urine HGA levels. Vascular calcifications were seen in the coronaries, cardiac valves, aortic root, descending aorta and iliac arteries. These findings suggest an important role for echocardiographic screening of alkaptonuria patients to detect valvular heart disease and cardiac CT to detect coronary artery calcifications. Published by Elsevier Inc.

  1. Acquired pulmonary artery stenosis in four dogs.

    Science.gov (United States)

    Scansen, Brian A; Schober, Karsten E; Bonagura, John D; Smeak, Daniel D

    2008-04-15

    4 dogs with acquired pulmonary artery stenosis (PAS) were examined for various clinical signs. One was a mixed-breed dog with congenital valvular PAS that subsequently developed peripheral PAS, one was a Golden Retriever with pulmonary valve fibrosarcoma, one was a Pembroke Welsh Corgi in which the left pulmonary artery had inadvertently been ligated during surgery for correction of patent ductus arteriosus, and one was a Boston Terrier with a heart-base mass compressing the pulmonary arteries. All 4 dogs were evaluated with 2-dimensional and Doppler echocardiography to characterize the nature and severity of the stenoses; other diagnostic tests were also performed. The mixed-breed dog with valvular and peripheral PAS was euthanized, surgical resection of the pulmonic valve mass was performed in the Golden Retriever, corrective surgery was performed on the Pembroke Welsh Corgi with left pulmonary artery ligation, and the Boston Terrier with the heart-base mass was managed medically. Acquired PAS in dogs may manifest as a clinically silent heart murmur, syncope, or right-sided heart failure. The diagnosis is made on the basis of imaging findings, particularly results of 2-dimensional and Doppler echocardiography. Treatment may include surgical, interventional, or medical modalities and is targeted at resolving the inciting cause.

  2. Variable high gradient permanent magnet quadrupole (QUAPEVA)

    Science.gov (United States)

    Marteau, F.; Ghaith, A.; N'Gotta, P.; Benabderrahmane, C.; Valléau, M.; Kitegi, C.; Loulergue, A.; Vétéran, J.; Sebdaoui, M.; André, T.; Le Bec, G.; Chavanne, J.; Vallerand, C.; Oumbarek, D.; Cosson, O.; Forest, F.; Jivkov, P.; Lancelot, J. L.; Couprie, M. E.

    2017-12-01

    Different applications such as laser plasma acceleration, colliders, and diffraction limited light sources require high gradient quadrupoles, with strength that can reach up to 200 T/m for a typical 10 mm bore diameter. We present here a permanent magnet based quadrupole (so-called QUAPEVA) composed of a Halbach ring and surrounded by four permanent magnet cylinders. Its design including magnetic simulation modeling enabling us to reach 201 T/m with a gradient variability of 45% and mechanical issues are reported. Magnetic measurements of seven systems of different lengths are presented and confirmed the theoretical expectations. The variation of the magnetic center while changing the gradient strength is ±10 μm. A triplet of QUAPEVA magnets is used to efficiently focus a beam with large energy spread and high divergence that is generated by a Laser Plasma Acceleration source for a free electron laser demonstration and has enabled us to perform beam based alignment and control the dispersion of the beam.

  3. Introduction to the permanent magnet motor market

    Energy Technology Data Exchange (ETDEWEB)

    Sawa, Toshihiro; Hamada, Kaneyuki [Yaskawa Electric Corp. (Japan)

    2000-07-01

    According to the Kyoto summit on global warming (COP3) in December 1997, the green-house gas emission level has to be reduced to 92-94% of the 1990 green-house gas level by the year 2014-2018. This would require conserving energy. An efficient means of achieving this voluntary goal is by employing high-efficiency drives, since motors consume 70% of all electricity for industrial use in Japan. As adjustable speed drives become popular, interior permanent magnet (IPM) motors, lately, have been recognized for high-efficiency performance. Due to the progress in permanent magnet technology combined with modern control methods, especially vector control with and without speed-sensors, the IPM motor is gaining in popularity. Compact size and high-efficiency performance is furthering the IPM motor as the preferred motor in many applications. This paper describes the principle and operation of IPM motors and compares its performance with that of an induction motor. Important features and practical control methods for IPM motors are presented. Various application examples highlighting the advantages of employing an IPM motor system are discussed. The applications include, but are not limited to, machine tools, fans, pumps, elevators, cranes, etc. (orig.)

  4. Permanent synchronization of camcorders via LANC protocol

    Science.gov (United States)

    Vrancic, Damir; Smith, Steven L.

    2006-02-01

    A device, which keeps two camcorders permanently in synchronization, has been developed. The mentioned device uses LANC (CONTROL-L) camcorder's inputs for synchronization. It enables controlling of two camcorders simultaneously via built-in buttons, by using external LANC remote controller and/or by the PC via serial (RS232) communication. Since device requires LANC inputs on camcorders or ACC inputs on still cameras, it can be used on some camcorders produced by manufacturers Sony and Canon or some still cameras produced by Sony. The device initially synchronizes camcorders or still cameras by applying arbitrarily delayed power-up pulses on LANC (ACC) inputs. Then, on user demand, the camcorders can be permanently synchronized (valid only for some camcorders produced by Sony). The effectiveness of the proposed device is demonstrated by several experiments on three types of camcorders (DCR-TRV900E, HDR-HC1, HVR-Z1U) and one type of still camera (DSC-V1). The electronic schemes, PCB layouts, firmware and communication programs are freely available (under GPL licence).

  5. Large permanent magnet quadrupoles for an electron storage ring

    International Nuclear Information System (INIS)

    Herb, S.W.

    1987-01-01

    We have built large high quality permanent magnet quadrupoles for use as interaction region quadrupoles in the Cornell Electron Storage Ring where they must operate in the 10 kG axial field of the CLEO experimental detector. We describe the construction and the magnetic measurement and tuning procedures used to achieve the required field quality and stability. (orig.)

  6. Development of Object Permanence in Visually Impaired Infants.

    Science.gov (United States)

    Rogers, S. J.; Puchalski, C. B.

    1988-01-01

    Development of object permanence skills was examined longitudinally in 20 visually impaired infants (ages 4-25 months). Order of skill acquisition and span of time required to master skills paralleled that of sighted infants, but the visually impaired subjects were 8-12 months older than sighted counterparts when similar skills were acquired.…

  7. Permanent magnets in accelerators can save energy, space and cost

    DEFF Research Database (Denmark)

    Bødker, F.; Baandrup, L.O.; Hauge, N.

    2013-01-01

    coils permit fine tuning of the magnetic field. Magnetic field measurements and thermal stability tests show that the Green Magnet fully meets the magnetic requirements of the previously used electromagnet. A permanent 30° bending dipole is currently being development to demonstrate the use of Green...

  8. Forces Between a Permanent Magnet and a Soft Magnetic Plate

    DEFF Research Database (Denmark)

    Beleggia, Marco; Vokoun, David; De Graef, Marc

    2012-01-01

    Forces between a hard/permanent magnet of arbitrary shape and an ideally soft magnetic plate in close proximity are derived analytically from the image method applied to magnetostatics. We found that the contact force, defined as the force required to detach the hard magnet from the plate, coinci...

  9. Permanent magnets including undulators and wigglers

    CERN Document Server

    Bahrdt, J

    2010-01-01

    After a few historic remarks on magnetic materials we introduce the basic definitions related to permanent magnets. The magnetic properties of the most common materials are reviewed and the production processes are described. Measurement techniques for the characterization of macroscopic and microscopic properties of permanent magnets are presented. Field simulation techniques for permanent magnet devices are discussed. Today, permanent magnets are used in many fields. This article concentrates on the applications of permanent magnets in accelerators starting from dipoles and quadrupoles on to wigglers and undulators.

  10. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring for surgical hip repair in two patients with severe aortic stenosis

    Directory of Open Access Journals (Sweden)

    María Mercedes López

    2016-02-01

    Full Text Available BACKGROUND AND OBJECTIVES: Aortic stenosis increases perioperative morbidity and mortality, perioperative invasive monitoring is advised for patients with an aortic valve area 30 mm Hg and it is important to avoid hypotension and arrhythmias. We report the anaesthetic management with continuous spinal anaesthesia and minimally invasive haemodynamic monitoring of two patients with severe aortic stenosis undergoing surgical hip repair. CASE REPORT: Two women with severe aortic stenosis were scheduled for hip fracture repair. Continuous spinal anaesthesia with minimally invasive haemodynamic monitoring was used for anaesthetic management of both. Surgery was performed successfully after two consecutive doses of 2 mg of isobaric bupivacaine 0.5% in one of them and four consecutive doses in the other. Haemodynamic conditions remained stable throughout the intervention. Vital signs and haemodynamic parameters remained stable throughout the two interventions. CONCLUSION: Our report illustrates the use of continuous spinal anaesthesia with minimally invasive haemodynamic monitoring as a valid alternative to general or epidural anaesthesia in two patients with severe aortic stenosis who are undergoing lower limb surgery. However, controlled clinical trials would be required to establish that this technique is safe and effective in these type or patients.

  11. Optimally segmented permanent magnet structures

    DEFF Research Database (Denmark)

    Insinga, Andrea Roberto; Bjørk, Rasmus; Smith, Anders

    2016-01-01

    We present an optimization approach which can be employed to calculate the globally optimal segmentation of a two-dimensional magnetic system into uniformly magnetized pieces. For each segment the algorithm calculates the optimal shape and the optimal direction of the remanent flux density vector......, with respect to a linear objective functional. We illustrate the approach with results for magnet design problems from different areas, such as a permanent magnet electric motor, a beam focusing quadrupole magnet for particle accelerators and a rotary device for magnetic refrigeration....

  12. Magnetostatic interactions and forces between cylindrical permanent magnets

    International Nuclear Information System (INIS)

    Vokoun, David; Beleggia, Marco; Heller, Ludek; Sittner, Petr

    2009-01-01

    Permanent magnets of various shapes are often utilized in magnetic actuators, sensors or releasable magnetic fasteners. Knowledge of the magnetic force is required to control devices reliably. Here, we introduce an analytical expression for calculating the attraction force between two cylindrical permanent magnets on the assumption of uniform magnetization. Although the assumption is not fulfilled exactly in cylindrical magnets, we obtain a very good agreement between the calculated and measured forces between two identical cylindrical magnets and within an array of NdFeB cylindrical magnets.

  13. [POSTRESUSCITATION CICATRICIAL TRACHEAL STENOSIS. CURRENT STATE OF THE PROBLEM - THE SUCCESSES, THE HOPES AND DISAPPOINTMENTS.

    Science.gov (United States)

    Parshin, V D; Vyzhigina, M A; Rusakov, M A; Parshin, V V; Titov, V A; Starostin, A V

    2016-09-01

    , the principle of "every patient his own version of operation" allows to minimize the risk oftreatment and to get a good lasting result. Proof of such provision may be the fact that the frequency of complications and postoperative mortality at our patients have had a tendency to decrease and currently stands at 12.9 and 0.7 %, respectively for many years. It is 2.3 and 9.6 times less, respectively, than in the periodfrom 1963 to 2000. It appears that further reduction of these indicators will be at a slower pace, afurther solution of the CTS problem will be based on the prevention of disease. Prevention of cicatricial tracheal stenosis in the departments of reanimation and intensive care is currently inadequate. It requires fundamentally new approaches, but reform still has not brought the desired results. Diagnosis of the CTS at an early stage allows early treatment and to avoid complex and risky operations. Increasingly important, apart tracheoscopy for diagnosis of tracheomalacia purchase dynamic computed tomography and magnetic resonance - tomography. Treatment ofpatients with CTS requires a multidisciplinary approach, individual selection operations for a particular patient. The general trend of the further development of tracheal surgery is associated with an increase in the number of simultaneous resections, including at the long, two-level stenosis, as well as at relapse. The patients who had refused treatment or have elected him palliative options made possible surgery. The frequency of postoperative comnlications and mortality decreased significantiv, including after extensive and traumatic operations on the trachea.

  14. Endovascular treatment of central venous stenosis and obstruction in hemodialysis patients.

    Science.gov (United States)

    Shi, Ya-xue; Ye, Meng; Liang, Wei; Zhang, Hao; Zhao, Yi-ping; Zhang, Ji-wei

    2013-02-01

    Central venous stenosis and obstruction (CVD) is a serious and prevalent challenge to both resolve the venous hypertension symptoms and maintain the pantency of the ipsilateral hemodialysis access in hemodialysis patients. This study aimed to summarize our experience of the endovascular management of the central venous stenosis or obstruction in hemodialysis patients. Twenty-four haemodialysis cases of central vein stenosis or obstruction with ipsilateral functional vascular access in our hospital between July 2006 and February 2012 were treated by interventional therapy and the data were analyzed retrospectively. Eighteen males and six females with mean age of (66.4 ± 13.8) years and manifesting with arm swelling and venous hypertension were enrolled; 62.5% of them had a history of catheterization. Venography showed stenotic lesion in 10 cases including eight cases of brachiocephalic vein stenosis and two cases of subclavian vein stenosis and 14 cases of obstruction lesions including seven cases of short brachiocephalic obstruction and seven cases of long segment obstruction. Interventional therapy was performed and the technique success rate was 83.3%. Percutaneous transluminal angioplasty (PTA) was performed in nine cases and stent was performed in 11 cases firstly. The symptoms of venous hypertension were resolved after intervention in all the cases. There was no major complication and death perioperatively. During follow-up, reintervention was done, the primary patency rates were (88.9 ± 10.5)%, (64.8 ± 10.5)% and (48.6 ± 18.7)% at 3 months, 6 months and 1 year after treatment in the PTA group; (90.0 ± 9.5)% and (77.1 ± 14.4)% at 6 months and 1 year after treatment in the stent group, respectively. The secondary patency rates were (48.6 ± 18.7)% in the PTA group and (83.3 ± 15.2)% in the stent group 1 year after treatment, respectively. There was no significant difference between the two groups (primary patency, P = 0.20; secondary patency, P = 0

  15. Update on the Essure System for Permanent Birth Control.

    Science.gov (United States)

    Fantasia, Heidi Collins

    In 2002, the U.S. Food and Drug Administration approved the Essure system for permanent birth control. Implantation with this device offers a minimally invasive option for permanent female contraception that is placed during a brief office visit. Unlike laparoscopic tubal sterilization, the Essure procedure requires no hospitalization or general anesthesia, resulting in minimal recovery time. After a decade of stability in the report of adverse effects, the U.S. Food and Drug Administration noted a sharp increase in patient-reported adverse events, including chronic pelvic pain, irregular bleeding, allergic reactions, and autoimmune-like reactions. In response to this increase in complaints, the U.S. Food and Drug Administration issued updated guidelines for patient education and counseling. This article discusses those updates, as well as implications for nurses who provide health care to women seeking permanent contraception. © 2017 AWHONN, the Association of Women’s Health, Obstetric and Neonatal Nurses.

  16. Diagnostic method for lumbar foraminal stenosis based on the clinical results of transforaminal lumbar interbody fusion (TLIF). Utility of the foraminal stenosis score

    International Nuclear Information System (INIS)

    Yamada, Katsutaka; Nakamura, Jun-ichiro; Mitsugi, Naoto; Sato, Masatsune; Saito, Tomoyuki

    2010-01-01

    In this study we analyzed 73 cases treated by transforaminal lumbar interbody fusion (TLIF) for lumbar foraminal stenosis or central canal stenosis and foraminal stenosis, and based on the perioperative findings and outcome of treatment, we considered the diagnostic procedure for lumbar foraminal stenosis in the future. In 25 cases (34.2%) cases there was actually no clear perioperative evidence of foraminal stenosis. We compared the preoperative clinical and imaging findings in the group with perioperative findings and the group without perioperative findings performed a multiple logistic regression analysis to identify factors associated with foraminal stenosis. We also calculated the odds ratio for the perioperative findings and proposed a foraminal stenosis scoring system. (author)

  17. Electrical energy supply with permanent energy sources

    Energy Technology Data Exchange (ETDEWEB)

    1981-05-01

    It can be shown that there are no chances for solar and wind power plants in Northern Europe when estimating the investment costs and the floor space required. However, the decentralized utilization of the plants which is likely to become very interesting in a few years shows other results. As a complete annual balance by traditional stores would cause a considerably uneconomic increase of the investment costs supplementary energy sources are inevitable. The author points out how the various primary energy sources in question can be utilized and combined with each other. He describes the converters for the permanent (regenerative) energy sources, the available electrochemical stores and their application as well as the fundamental structures of the energy supply systems. Finally some advice is given regarding the recycling of energy and the operation by the consumers.

  18. Temporality and permanence in Romanian public art

    Directory of Open Access Journals (Sweden)

    Maria-Judit Balko

    2015-09-01

    Full Text Available This paper analyzes the relationship between permanent monuments and temporary art projects, as temporality is one of the strategies employed by Romanian artists to counterbalance the support that the Romanian state has shown only towards monuments and memorials dedicated to affirming its value. The complex nature of public art requires a careful consideration of the different dimensions this practice employs, and for that the Western debate on this matter can be a reference point in understanding Romanian public art. We will be looking at possible aspects of the functions of these two main directions in Romanian public art, as they stand methodically one in opposition to the other, in connection with the texts of Piotr Piotrowski (Art and Democracy in Post-communist Europe, 2012 and Boris Groys (Art Power, 2008.

  19. Contributory Factors Related to Permanent Deformation of Hot Asphalt Mixtures

    Directory of Open Access Journals (Sweden)

    Alaa Husein Abd

    2017-03-01

    Full Text Available Permanent deformation (Rutting of asphalt pavements which appears in many roads in Iraq, have caused a major impact on pavement performance by reducing the useful service life of pavement and creating services hazards for highway users. The main objective of this research is investigating the effect of some contributory factors related to permanent deformation of asphalt concrete mixture. To meet the objectives of this research, available local materials are used including asphalt binder, aggregates, mineral filler and modified asphalt binder. The Superpave mix design system was adopted with varying volumetric compositions. The Superpave Gyratory Compactor was used to compact 24 asphalt concrete cylindrical specimens. To collect the required data and investigate the development of permanent deformation in asphalt concrete under repeated loadings, Wheel-Tracking apparatus has been used in a factorial testing program during which 44 slab samples; with dimensions of 400×300×50 mm; were tested to simulate . actual pavement. Based on wheel-tracking test results, it has been concluded that increasing the compaction temperature from 110 to 150ºC caused a decreasing in permanent deformation by 20.5 and 15.6 percent for coarse and fine gradation control asphalt mixtures respectively. While the permanent deformation decreased about 21.3 percent when the compaction temperature is increased from 110 to 150ºC for coarse gradation asphalt mixtures modified with styrene butadiene styrene SBS with 3 percent by asphalt binder weight.

  20. Elective extractions of first permanent molars: a review

    Directory of Open Access Journals (Sweden)

    Melike Kiraz

    2018-05-01

    Full Text Available Permanent first molar teeth possess a key role in the setting-up of the occlusion, contribute significantly to the chewing function and serve as a guide for other teeth. However, it is frequently encountered that permanent first molar teeth are extracted due to the predicted negative prognoses of caries or developmental defects. As a result of the uncontrolled extraction of the permanent first molar teeth during the growth and development period, drifting of adjacent teeth, continued eruption of the opposing teeth and displacements can be seen. Furthermore, following one-sided extraction, midline deviations, oppositional tooth eruption, skeletal and dental asymmetry, unilateral chewing habits, and temporo-mandibular joint disorders may occur. To prevent these pathological conditions and to maintain the stability of the occlusal relation, it is necessary to do compensation and balancing extractions of the permanent first molar teeth on the opposite/symmetric arc, assuming mesial drag of the permanent second and third molar teeth. With such controlled-extractions, especially in Class I cases, orthodontic or prosthetic treatments, which may require extra time, cost and effort, could be prevented and a conceivable occlusion can be established.

  1. Effectiveness and safety of endoscopic radial incision and cutting for severe benign anastomotic stenosis after surgery for colorectal carcinoma: a three-case series.

    Science.gov (United States)

    Asayama, Naoki; Nagata, Shinji; Shigita, Kenjiro; Aoyama, Taiki; Fukumoto, Akira; Mukai, Shinichi

    2018-03-01

    Benign colonic anastomotic stenosis sometimes occurs after surgical resection and usually requires surgical or endoscopic dilation. Limited data are available on the effectiveness and safety of the endoscopic radial incision and cutting (RIC) method at sites other than the esophagus. The aim of this retrospective study was to investigate the effectiveness and safety of RIC dilation for severe benign anastomotic colonic stenosis. Subjects were 3 men (median age 72 years, range 65 - 76 years) who developed severe benign anastomotic stenosis after surgical resection for colorectal carcinoma and were subsequently treated by RIC dilation at Hiroshima City Asa Citizens Hospital between May 2014 and December 2016. Severe anastomotic stenosis was defined as a narrowed anastomosis through which a standard colonoscope could not be passed. The median interval from surgery to RIC was 21 months (range 9 - 29 months). RIC was successful in all 3 patients and reduced the severity of dyschezia postoperatively; 2 patients experienced improvement after a single RIC session and the other after 6 RIC sessions. No treatment-related adverse events or re-stenosis requiring repeat dilation was noted during a median follow-up of 27 months (range 8 - 37 months). Our findings indicate that the RIC technique can be applied safely and effectively to various sites in the colon, avoiding the need for reoperation.

  2. The evidence for medicine versus surgery for carotid stenosis

    International Nuclear Information System (INIS)

    Ederle, Joerg; Brown, Martin M.

    2006-01-01

    Atherosclerotic stenosis of the internal carotid artery is an important cause of stroke. Several large randomised trials have compared best medical management with carotid endarterectomy and provide a strong evidence base for advising and selecting patients for carotid surgery. Best medical management of carotid stenosis includes lowering of blood pressure, treatment with statins and antiplatelet therapy in symptomatic patients. Combined analysis of the symptomatic carotid surgery trials, together with observational data, has shown that patients with recently symptomatic severe carotid stenosis have a very high risk of recurrent stroke in the first few days and weeks after symptoms. Carotid endarterectomy has a risk of causing stroke or death at the time of surgery in symptomatic patients of around 5-7%, but in patients with recently symptomatic stenosis of more than 70%, the benefits of endarterectomy outweigh the risks. In patients with moderate stenosis of between 50 and 69%, the benefits may justify surgery in patients with very recent symptoms, and in patients older than 75 years within a few months of symptoms. Patients with less than 50% stenosis do not benefit from surgery. In asymptomatic patients, or those whose symptoms occurred more than 6 months ago, the benefits of surgery are considerably less. Patients with asymptomatic stenosis treated medically only have a small risk of future stroke when treated medically of about 2% per annum. If carotid endarterectomy can be performed safely with a perioperative stroke and death rate of no more than 3%, then the randomised trials showed a significant benefit of surgery over 5 years follow-up, with an overall reduction in the risk of stroke from about 11% over 5 years down to 6%. However, of 100 patients operated, only 5 will benefit from avoiding a stroke over 5 years. The majority of neurologists have concluded that this does not justify a policy of routine screening and endarterectomy for asymptomatic

  3. Permanent magnet-based MRI

    Science.gov (United States)

    Cole, David Mitchell

    1997-10-01

    The principal goal of this project is to design and build a low-cost, imaging quality permanent magnet, together with the requisite shim, gradient, and radiofrequency coils, and to integrate the magnet with an existing imaging station. There are commercial products presently available that are very similar to this imager, but information about these products is proprietary. We present here all of the details concerning the design and the manufacturing process for constructing the permanent magnet, and include suggestions for improvement. Specifically, the prototype has a mass of about 150 kilograms and is therefore portable. It's C-type geometry allows maximum access to the imaging region, which is an oblate sphere about 0.5 inches in diameter centered in a 4.7 inch air gap between two seven-inch diameter polefaces. It is hoped that this imaging magnet will serve as the prototype for a series of larger versions that will be clinically useful and affordable to physicians in developing nations. To this end, scientists in the United States and Mexico have begun to collaborate with the intention to create an MRI institute in Mexico that will train new students in this discipline, and fabricate improved imagers. The prototype resulting from this work will seed the creation of this institute, and is intended to entice students into the study of MRI by enabling hands-on interaction with an otherwise prohibitively expensive instrument.

  4. Permanent burying method for product

    International Nuclear Information System (INIS)

    Sakai, Goro; Sakata, Noboru; Hironaka, Yoshikazu; Shigematsu, Kazuo; Yurugi, Masahiro; Minami, Masayoshi; Yoshisaki, Masato.

    1995-01-01

    In a method of permanently burying an object by filling and solidifying a cement mortar in gaps between each of objects to be buried underground, cement mortar is filled into gaps, which comprises water at a unit amount determined as from 200 to 250kg/m 3 , a cement at low water/cement ratio (%) of from 70 to 400%, and contains fine powder having an average grain size of not greater than 100μm (not containing cement) of 50 to 800kg/m 3 , fine aggregates of 800 to 1200kg/m 3 , UERAN gum (a bio-gum powder produced by aerobic fermentation of alcaligenes-bacteria) of 20g/m 3 to 1.3kg/m 3 , a dispersing agent of 0 to 40kg/m 3 , a swelling agent of 0 to 40kg/m 3 . Then if the mortar blended with the UERAN gum is injected, any gaps can be filled tightly, no breeding is caused and since the amount of cement is small, it does not suffer from temperature cracking. Therefore, the state of filling is kept permanently, and environmental pollution caused by radioactive wastes can be prevented. (N.H.)

  5. The Permanent Magnet Operating Mechanism of Double Coil Parallel Driven at a High Speed

    Directory of Open Access Journals (Sweden)

    WEI Xau-Lao

    2017-02-01

    Full Text Available Abstract:Operating mechanism is the main part of breaker,and the quality of breaker will directly influence the safe operation of power system. Because of the continuous improvement requirements of switch,in order to mak this actuator faster and more powerful closing,this paper proposes a double coil parallel driven permanent magnet actuator at a high speed. This paper expounds the working principle of single and double coil parallel driven permanent magnet actuator. It uses Ansoft building model and contrasts test results. In prance we designed and produced the single and double coil parallel driven permanent magnet actuator for experimental study. The simulation and experiment results show that double coil parallel driven permanent magnet actuator,compared with single coil parallel driven permanent magnet actuator,has a better and faster action performance. Thus,the double coil parallel driven permanent magnet actuator achieves a kind of optimization.

  6. Covered Balloon-Expanding Stents in Airway Stenosis.

    Science.gov (United States)

    Majid, Adnan; Kheir, Fayez; Chung, Jey; Alape, Daniel; Husta, Bryan; Oh, Scott; Folch, Erik

    2017-04-01

    The balloon-expanding stents are widely available but rarely described for use within the tracheobronchial tree. This report describes our experience with these stents in airway stenosis particularly as a lobar salvage therapy. This was a retrospective review of all records in which the balloon-expanding stents were used at a tertiary medical center. Ages, sex, location of stenosis, etiology of stenosis, stent size, duration of stent placement and associated interventions for airway stenosis were recorded. Patient's self-reported respiratory symptoms, dyspnea scale, and radiographic imaging at baseline and after stent placement were also reported. Twenty-one Atrium iCAST stents were inserted in 18 patients with malignant and benign airway disease. The median age was 69.5 years (interquartile range, 53.5 to 74). Most stents (n=20, 95%) were deployed in the lobar airways. There was a significant improvement in the modified Medical Research Council dyspnea scale from median of 3 to 2 (Pstent placement was achieved in 15 patients (83%). No deaths were related to airway stenting complications. Adverse events related to stents included migration (n=2, 9.5%), granulation tissue formation (n=2, 9.5%) and mucus plugging (n=1, 4.8%). Lobar stenting with balloon-expanding metallic stents appears feasible, safe and improves symptoms as well as radiographic atelectasis in patients with lobar airway stenosis in this small case series. Larger studies are needed to confirm this observation and to address long-term safety.

  7. Vestibulovaginal stenosis in dogs: 18 cases (1987-1995).

    Science.gov (United States)

    Kyles, A E; Vaden, S; Hardie, E M; Stone, E A

    1996-12-01

    To evaluate vestibulovaginal stenosis in dogs. Retrospective study. 18 dogs with vestibulovaginal stenosis diagnosed between January 1987 and June 1995. Signalment, results of physical examination, and diagnostic testing, treatment, and outcome were analyzed. Mean age at initial examination was 4.6 years. Problems reported by the owners included signs of chronic urinary tract infection (6 dogs), urinary incontinence (4), failure to mate (4), signs of chronic vaginitis (2), and inappropriate urination (1). One dog did not have evidence of a clinical problem. Vestibulovaginal stenosis was detected by means of digital vaginal examination (18/18 dogs), vaginoscopy (17/17 dogs), and positive-contrast vaginography (9/10 dogs). Bacteria were isolated from the urine of 11 of 15 dogs. Twelve of 18 dogs were treated. Manual dilation (4 dogs) and T-shaped vaginoplasty (4) were less successful than vaginectomy (2) or resection of the stenotic area (3). Four of 6 dogs with signs of recurrent urinary tract infection underwent surgical correction, and none of these dogs subsequently had urinary tract infection. Three of 4 dogs with urinary incontinence responded to medical or surgical treatment for sphincter incompetence or for ectopic ureters. Surgical correction of vestibulovaginal stenosis is indicated in dogs that have mating difficulties or signs of recurrent urinary tract infection or chronic vaginitis, but stenosis is probably an incidental finding in most dogs with urinary incontinence. Vaginectomy and vaginal resection and anastomosis are the preferred surgical options.

  8. Efficacy of transoral intraluminal Wallstents for tracheal stenosis or tracheomalacia.

    Science.gov (United States)

    Casiano, R R; Numa, W A; Nurko, Y J

    2000-10-01

    The efficacy and safety of intraluminal Wallstent Endoprosthesis (Boston Scientific/ Medi-Tech, Quincy, MA) placement to restore airway patency in patients with tracheal stenosis or tracheomalacia are unknown. Retrospective review in setting of tertiary, referral, and academic center. A retrospective review of 13 consecutive patients over a 2-year period who underwent transoral resection of tracheal stenosis and immediate transoral Wallstent placement. One patient had tracheomalacia. All of the patients were considered at high risk for transcervical surgery or had failed prior traditional open procedures. The average patient age was 54.2 years, with nine male and four female patients. All had Cotton/Myer stenoses (grades II to IV) with moderate to severe degrees of inspiratory stridor. Four patients were tracheotomy dependent. The length of stenosis varied from 1 to 4 cm. One patient had a 10-cm segment of tracheomalacia. At the time of writing, none of the patients has had a problem with significant migration or extrusion and most of the patients have incorporated the stent well without any short-term obstructive granulation tissue. After a mean follow-up of 15 months (range, 4-24 mo). 10 of the 12 patients with stenosis (83%) have remained free of any inspiratory noise during breathing. The one patient with tracheomalacia also has remained free of symptoms. Transoral Wallstents appear to be safe and may be a reasonable alternative in the restoration of airway patency in select patients with tracheal stenosis or tracheomalacia.

  9. Influence of End-Effects on Static Torque Performance of Misaligned Cylindrical Permanent Magnet Couplings

    DEFF Research Database (Denmark)

    Högberg, Stig; Hansen, Hilary; Jensen, Bogi Bech

    2014-01-01

    Permanent magnet couplings are widely used in applications requiring torque to be transmitted through an air- gap. The aim of this study is to observe and explain the effect of radial and axial misalignment in a 12-pole, cylindrical permanent magnet coupling. Pull-out torque was measured for two...

  10. 38 CFR 3.342 - Permanent and total disability ratings for pension purposes.

    Science.gov (United States)

    2010-07-01

    ... applied with other types of disabilities requiring hospitalization for indefinite periods. The need for... permanency of total disability contained in § 3.340, the following special considerations apply in pension... permanence of total disability will be established as of the earliest date consistent with the evidence in...

  11. Enterprise stenting for intracranial aneurysm treatment induces dynamic and reversible age-dependent stenosis in cerebral arteries.

    Science.gov (United States)

    Gao, Bulang; Safain, Mina G; Malek, Adel M

    2015-04-01

    Although intracranial stenting has been associated with in-stent stenosis, the vascular response of cerebral vessels to the deployment of the Enterprise vascular reconstruction device is poorly defined. To evaluate the change in parent vessel caliber that ensues after Enterprise stent placement. Seventy-seven patients with 88 aneurysms were treated using Enterprise stent-assisted coil embolization and underwent high-resolution three-dimensional rotational angiography followed by three-dimensional edge-detection filtering to remove windowing-dependence measurement artifact. Orthogonal diameters and cross-sectional areas (CSAs) were measured proximal and distal on either side of the leading stent edge (points A, B), trailing stent edge (points D, E), and at mid-stent (point C). Enterprise stent deployment caused an instant increase in the parent artery CSA by 8.98% at D, which was followed 4-6 months later by significant in-stent stenosis (15.78% at A, 27.24% at B, 10.68% at C, 32.12% at D, and 28.28% at E) in the stented artery. This time-dependent phenomenon showed resolution which was complete by 12-24 months after treatment. This target vessel stenosis showed significant age dependence with greater response in the young. No flow-limiting stenosis requiring treatment was observed in this series. Use of the Enterprise stent is associated with a significant dynamic and spontaneously resolvable age-dependent in-stent stenosis. Further study is warranted on the clinical impact, if any, of this occurrence. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Evaluation of the carotid artery stenosis based on minimization of mechanical energy loss of the blood flow.

    Science.gov (United States)

    Sia, Sheau Fung; Zhao, Xihai; Li, Rui; Zhang, Yu; Chong, Winston; He, Le; Chen, Yu

    2016-11-01

    Internal carotid artery stenosis requires an accurate risk assessment for the prevention of stroke. Although the internal carotid artery area stenosis ratio at the common carotid artery bifurcation can be used as one of the diagnostic methods of internal carotid artery stenosis, the accuracy of results would still depend on the measurement techniques. The purpose of this study is to propose a novel method to estimate the effect of internal carotid artery stenosis on the blood flow based on the concept of minimization of energy loss. Eight internal carotid arteries from different medical centers were diagnosed as stenosed internal carotid arteries, as plaques were found at different locations on the vessel. A computational fluid dynamics solver was developed based on an open-source code (OpenFOAM) to test the flow ratio and energy loss of those stenosed internal carotid arteries. For comparison, a healthy internal carotid artery and an idealized internal carotid artery model have also been tested and compared with stenosed internal carotid artery in terms of flow ratio and energy loss. We found that at a given common carotid artery bifurcation, there must be a certain flow distribution in the internal carotid artery and external carotid artery, for which the total energy loss at the bifurcation is at a minimum; for a given common carotid artery flow rate, an irregular shaped plaque at the bifurcation constantly resulted in a large value of minimization of energy loss. Thus, minimization of energy loss can be used as an indicator for the estimation of internal carotid artery stenosis.

  13. Emergency interventional therapy of peripheral arterial stenosis and thrombosis

    International Nuclear Information System (INIS)

    Cai Fengquan; Yu Xixiang

    2004-01-01

    Objective: To evaluate the clinical value of emergency interventional therapy of stenosis and thrombosis of peripheral arteries. Methods: 26 patients suffered from stenosis and thrombosis of peripheral arteries including, 3 subclavical arteries, 5 iliac arteries, 7 femoral arteries, 4 popliteal arteries, 4 posterior or anterior tibial arteries, 2 graft vessels and 1 instent restenosis were undertaken interventional ATD or urokinase infusion thrombolysis, percutanous transluminal angioplasty (PTA) and stent placement. Results: The stenotic arteries were recanalized after PTA or stent placement and the thrombosis vanished after thrombolysis with distal flowes improved or resumed. Clinical symptom was ameliorated. No more complication occurred except one patient with alimentary hemorrhage after thrombolysis. The patients were followed up from 1 to 20 months with all the involved arteries keeping in constant patency without any amputation. Conclusions: Emergency thrombolysis by machine or drug along with PTA or stent placement can effectively cure the stenosis or thrombosis of peripheral artery with recanalization and no amputation. (authors)

  14. Frequency of renal artery stenosis in patients undergoing cardiac catheterization

    International Nuclear Information System (INIS)

    Lashari, M.N.; Ahmed, R.; Soomro, K.; Ishaq, M.

    2009-01-01

    Due to scarcity of local data regarding frequency of Renal Artery Stenosis (RAS), it is important to perform simultaneous renal arteriography in Patients undergoing coronary arterteriography for suspected coronary artery disease (CAD), in order to recognize all potential candidates for renal artery stenosis. It is cross sectional study. Three hundred patients, 157 male and 143 female with average age of 56+-8 Years and 55+-7 years respectively underwent simultaneous coronary and renal arteriography. Renal artery stenosis (RAS) was identified in 23.6% patients. Significant RAS (>50%) was present in 15% of patients. Hypertension, Dyslipidemia, smoking and diabetes mellitus were present in 88%, 80%, 50% and 49% respectively. Three vessel, two vessel and single vessel disease were seen in 58 %, 36% and 6% of patients. It is important to do simultaneous coronary and renal arteriography especially in patient having multiple risk factors and multi vessel coronary artery disease. (author)

  15. Frequency of renal artery stenosis in patients undergoing cardiac catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Lashari, M N; Ahmed, R; Soomro, K; Ishaq, M [Civil Hospital, Karachi (Pakistan)

    2009-07-15

    Due to scarcity of local data regarding frequency of Renal Artery Stenosis (RAS), it is important to perform simultaneous renal arteriography in Patients undergoing coronary arterteriography for suspected coronary artery disease (CAD), in order to recognize all potential candidates for renal artery stenosis. It is cross sectional study. Three hundred patients, 157 male and 143 female with average age of 56+-8 Years and 55+-7 years respectively underwent simultaneous coronary and renal arteriography. Renal artery stenosis (RAS) was identified in 23.6% patients. Significant RAS (>50%) was present in 15% of patients. Hypertension, Dyslipidemia, smoking and diabetes mellitus were present in 88%, 80%, 50% and 49% respectively. Three vessel, two vessel and single vessel disease were seen in 58 %, 36% and 6% of patients. It is important to do simultaneous coronary and renal arteriography especially in patient having multiple risk factors and multi vessel coronary artery disease. (author)

  16. A case of William's syndrome associated peripheral pulmonary arterial stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kyung Hwa; Hwang, Mi Soo; Kim, Sun Yong; Chang, Jae Chun; Park, Bok Hwan [College of Medicine, Yeungam University, Daegu (Korea, Republic of)

    1988-06-15

    William's syndrome, in order to more completely delineate the total spectrum of the disorder, indicates that 'infantile hypercalcemia', 'peculiar facies' and 'supravalvular aortic stenosis.' In has other many vascular anomalies, such as peripheral pulmonary arterial stenosis, coronary arterial stenosis, celiac arterial stenosis, and renal aterial stenosis. Only 32% of the patients have evidence of supravalvular aortic stenosis. And it is very rare disease entity that has been reported rarely in Korea. Recently authors experienced a case that was questioned William's syndrome with peripheral pulmonary arterial stenosis, clinically and preliminary radiologically and this case was confirmed by operation. Here we report a case of William's syndrome with peripheral pulmonary arterial stenosis and reviewed literatures.

  17. Circulating MicroRNAs as Novel Biomarkers of Stenosis Progression in Asymptomatic Carotid Stenosis.

    Science.gov (United States)

    Dolz, Sandra; Górriz, David; Tembl, José Ignacio; Sánchez, Dolors; Fortea, Gerardo; Parkhutik, Vera; Lago, Aida

    2017-01-01

    Progression of asymptomatic carotid artery stenosis (ACAS) in patients with >50% luminal narrowing is considered a potential risk factor for ischemic stroke; however, subclinical molecular biomarkers of ACAS progression are lacking. Recent studies suggest a regulatory function for several microRNAs (miRNAs) on the evolution of carotid plaque, but its role in ACAS progression is mostly unknown. The aim of our study was to investigate a wide miRNA panel in peripheral blood exosomes from patients with ACAS to associate circulating miRNA expression profiles with stenosis progression. The study included 60 patients with ACAS carrying >50% luminal narrowing. First, miRNA expression profiles of circulating exosomes were determined by Affymetrix microarrays from plasma samples of 16 patients from the cohort. Second, those miRNAs among the most differentially expressed in patients with ACAS progression were quantified by real-time polymerase chain reaction in a separate replication cohort of 39 subjects within the patient sample. Our results showed that ACAS progression was associated with development of stroke. MiR-199b-3p, miR-27b-3p, miR-130a-3p, miR-221-3p, and miR-24-3p presented significant higher expression in those patients with ACAS progression. In conclusion, our study supports that specific circulating miRNA expression profiles could provide a new tool that complements the monitoring of ACAS progression, improving therapeutic approaches to prevent ischemic stroke. © 2016 American Heart Association, Inc.

  18. Treatment of Benign Tracheal Stenosis Using Endoluminal Spray Cryotherapy.

    Science.gov (United States)

    Bhora, Faiz Y; Ayub, Adil; Forleiter, Craig M; Huang, Chyun-Yin; Alshehri, Khalid; Rehmani, Sadiq; Al-Ayoubi, Adnan M; Raad, Wissam; Lebovics, Robert S

    2016-11-01

    Tracheal stenosis is a debilitating disorder with heterogeneity in terms of disease characteristics and management. Repeated recurrences substantially alter patients' quality of life. There is limited evidence for the use of spray cryotherapy (SCT) in the management of benign airway disease. To report our early results for the use of SCT in patients with benign tracheal stenosis. Data were extracted from the medical records of a consecutive series of patients with benign airway stenosis secondary to granulomatosis with polyangiitis (GPA) (n = 13), prior tracheotomy or tracheal intubation (n = 8), and idiopathic strictures (n = 5) treated from September 1, 2013, to September 30, 2015, at a tertiary care hospital. Airway narrowing was quantified on a standard quartile grading scale. Response to treatment was assessed by improvement in airway caliber and the time interval for reintervention. Delivery of 4 5-second SCT cycles and 2 balloon dilatations. Twenty-six patients (median [range] age, 53 [16-83] years; 20 [77%] female) underwent 48 SCT sessions. Spray cryotherapy was successfully used without any substantial intraoperative or postoperative complications in all patients. In a median (range) follow-up of 11 (1-26) months, all patients had improvement in symptoms. Before the institution of SCT, 23 patients (88%) had grade III or IV stenosis. At the last evaluation after induction of SCT, 4 (15%) had grade III or IV stenosis, with a mean (SD) change of 1.39 (0.51) (P benign tracheal stenosis. Although efficacy evidence is limited for SCT, it may be useful for patients who have experienced treatment failure with conventional modalities. Further analysis of this cohort will determine the physiologic durability of the reported short-term changes. Additional trials are warranted for further evaluation of this modality.

  19. Modern permanent magnetic materials - preparation and properties

    International Nuclear Information System (INIS)

    Rodewald, W.

    1989-01-01

    First of all, the basic properties of the classical (steel, AlNiCo) permanent magnetic materials and the modern rare-earth (RE) permanent magnetic materials are compared. Since the properties of RE permanent magnets depend on the particular production process, the fundamentals of the main industrial processes (powder metallurgy, rapid-solidification technique) are described and the typical properties are explained. Furthermore the production processes in development such as mechanical alloying, melt spinning technique and extrusion upsetting are briefly outlined. For applying the permanent magnets, they have to be completely magnetized. The magnetization behaviour of the various RE permanent magnets is discussed by means of the internal demagnetization curve. Finally the various influences on the temperature stability of RE permanent magnets are compiled. (orig./MM) [de

  20. Incidence, treatment and outcome of rectal stenosis following transanal endoscopic microsurgery.

    Science.gov (United States)

    Barker, J A; Hill, J

    2011-09-01

    As an alternative to more radical abdominal surgery, transanal endoscopic microsurgery (TEM) offers a minimally invasive solution for the excision of certain rectal polyps and early-stage rectal tumours. The patient benefits of TEM as compared to radical abdominal surgery are clear; nevertheless, some drawback is possible. The aim of our study was to determine the risk factors, treatment and outcomes of rectal stenosis following TEM. We analysed a series of 354 consecutive patients who underwent TEM for benign or malignant rectal tumours between 1997 and 2009. We recorded the maximum histological diameter of the lesion, and whether the lesion was circumferential. Rectal stenosis was defined as a rectal narrowing not allowing passage of a 12 mm sigmoidoscope. Histological results with a measured specimen diameter were available in 304 of the 354 cases. There were 11 stenoses in total (3.6%), 7 stenoses due to 9 circumferential lesions (78%) and 4 due to lesions with a maximum diameter ≥ 5 cm (3.2%). Two patients presented as emergencies, and the other 9 patients reported symptoms of increased stool frequency at follow-up. Three of the stenoses were associated with recurrent disease. All stenoses were treated by a combination of endoscopic/radiological balloon dilatation or surgically with Hegar's dilators. A median of two procedures were required to treat stenoses until resolution of symptoms. Rectal stenosis following TEM excision is rare. It is predictable in patients with circumferential lesions but is rare in patients with non-circumferential lesions with a maximum diameter ≥ 5 cm. It is effectively treated with surgical or balloon dilatation. Most patients require repeated treatments.

  1. Usefulness of MPR images of nephrogram in ureteropelvic junction stenosis

    International Nuclear Information System (INIS)

    Usui, Nobutaka; Munechika, Hirotsugu

    2005-01-01

    The study was to see if the multi-planar reconstruction (MPR) images of nephrogram were useful to evaluate the causative lesion of ureteropelvic junction (UPJ) stenosis. Thirty-two cases with UPJ stenosis were selected retrospectively for evaluation. MPR images were compared between nephrogram and ureterogram to see which was more useful for evaluation of the causative lesion. Most of the lesions were evaluated better in nephrogram or equal to ureterogram except for one case of a small ureteral tumor. MPR images in nephrogram were useful for evaluation of crossing vessels and a ureteral tumor. Benign stricture and calculi were also confirmed by the images. (author)

  2. Treatment of extensive post tonsillectomy oropharyngeal stenosis secondary to fibromatosis.

    Science.gov (United States)

    Chang, Brian; Ha, Jennifer F; Zopf, David

    2018-04-01

    Aggressive fibromatosis is an uncommon, benign tumor of fibroblastic origin with high potential for local invasion. Less than a quarter of these lesions are located in the head and neck, and although extremely rare, associations have been demonstrated with physical trauma. We describe a unique case of oropharyngeal fibromatosis with traumaticetiology, managed successfully with surgical excision of the lesion with negative surgical margins. A 5-year old patient was found to have an aggressive fibromatosis causing oropharyngeal stenosis following tonsillectomy. We demonstrate that surgical resection with a clear margin allowed for alleviation of stenosis without recurrences reported since the procedure. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Reduction mammoplasty as a treatment for symptomatic central venous stenosis

    Directory of Open Access Journals (Sweden)

    Denise Seok Fun Fok

    2018-03-01

    Full Text Available Central venous stenosis is a rare cause of unilateral breast edema occurring in hemodialysis patients that needs to be differentiated from other differential diagnoses, including, but not limited to, inflammatory breast carcinoma, mastitis, lymphedema, and congestive heart failure. All reports of similar cases in the available literature have described improvement or resolution of the edema after treatment. Herein, we report and discuss the pathophysiology of breast edema formation in a patient who presented with massive left-sided breast edema 7 years after being diagnosed with central venous stenosis. Medical and minimally invasive therapy had not been successful, so she underwent reduction mammoplasty to relieve the symptoms.

  4. Eigenimage filtering in the assessment of renal artery stenosis

    International Nuclear Information System (INIS)

    Windham, J.P.; Potvin, W.J.; Zhang, Y.; Farison, J.B.; Clarke, H.S.; Low, L.R.

    1986-01-01

    An image-filtering technique is applied in the evaluation of 13 dogs with surgically induced unilateral renal artery stenosis. A mathematical model representing first transit renal flow and glomerular filtration of Tc-99m DTPA is used to generate normal signature templates for vascular flow and cortex uptake from normal kidneys. These signatures are used to generate two weighting vectors where normal vascular flow and cortex uptake are desired processes and cortex uptake and vascular flow are interfering processes, respectively. From weighting vectors and kidney signature vectors, two indices are generated for quantitative analysis. Results of the study demonstrate that the technique is useful for evaluation of renal artery stenosis

  5. Polyflex stenting of tracheomalacia after surgery for congenital tracheal stenosis.

    Science.gov (United States)

    Tibballs, James; Fasulakis, Stephen; Robertson, Colin F; Berkowitz, Robert G; Massie, John; Brizard, Christian; Rose, Elizabeth; Bekhit, Elhamy; Eyres, Robert; Ragg, Philip

    2007-01-01

    Polyflex self-expanding stents (Rüsch, Germany) were used in three young children who had presented with life-threatening long-segment tracheal stenosis with bronchial stenosis in two cases. Two children had slide tracheoplasties and subsequently aortic homografts and another tracheal resection and autotracheoplasty. However, in all cases persistent lower tracheal malacia necessitated stenting. Complications of granuloma, stent migration or dislodgement occurred in all cases. A fatal tracheo-aortic fistula occurred in one child. Granuloma in one was treated successfully with steroids. One child survives.

  6. Radiologic management of hepatic arterial stenosis or thrombosis following liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Byung Suck; Sung, Kyu Bo; Lim, Soo Mee; Yoon, Hyun Ki; Song, Ho Young [Asan Medical Center, Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    2001-06-01

    To assess the results and usefulness of interventional procedures for hepatic arterial stenosis or thrombosis following liver transplantation. During the past five years, eight patients aged 1-59 (mean, 39) years among 187 liver transplant recipients showed elevated of liver enzyme levels (AST/ALT) and decreased arterial flow at Doppler ultrasound. Hepatic arteriography revealed luminal stenosis or occlusion at the proper hepatic artery, and six patients, one of whom required thrombolysis before the procedure, underwent percutaneous transluminal angioplasty (PTA) using a balloon. In two with thrombosis, thrombolysis without PTA was performed. In order to increase hepatic arterial flow, four patients underwent additional coil embolization of the gastroduodenal or splenic artery. Hepatic arterial flow recovered in all six patients after PTA. Three required repeat PTA for restenosis and one of these needed stent placement after repeated PTA. At follow-up, 6-17 months later, the three had good hepatic function. Within four days, the other three expired due to graft failure, hepatorenal syndrome and sepsis. One of the patients who underwent thrombolysis without PTA expired and the other required retransplantation. In this case there were no procedure - related complications. Radiologic interventions are useful for treatment of hepatic arterial stensis or thrombosis in patients with liver transplantations.

  7. Indexing aortic valve area by body surface area increases the prevalence of severe aortic stenosis

    DEFF Research Database (Denmark)

    Jander, Nikolaus; Gohlke-Bärwolf, Christa; Bahlmann, Edda

    2014-01-01

    To account for differences in body size in patients with aortic stenosis, aortic valve area (AVA) is divided by body surface area (BSA) to calculate indexed AVA (AVAindex). Cut-off values for severe stenosis are......To account for differences in body size in patients with aortic stenosis, aortic valve area (AVA) is divided by body surface area (BSA) to calculate indexed AVA (AVAindex). Cut-off values for severe stenosis are...

  8. Bronchoscopic management of benign bronchial stenosis by electrocautery and balloon dilatation.

    Science.gov (United States)

    Garg, M; Gogia, Pratibha; Manoria, P; Goyal, R

    2012-01-01

    Benign bronchial stenosis is managed by surgical or bronchoscopic methods. Although surgical approach is definitive, it is technically demanding and is costlier than bronchoscopic treatment. Here, we report the case of a 27-year-old female patient with symptomatic benign bronchial stenosis of the left main bronchus. The stenosis was dilated successfully through a fibreoptic bronchoscope by electrocautery followed by balloon bronchoplasty and application of mitomycin-C. On follow up, there was no evidence of re-stenosis.

  9. Intrusive luxation of 60 permanent incisors

    DEFF Research Database (Denmark)

    Tsilingaridis, Georgios; Malmgren, Barbro; Andreasen, Jens O

    2012-01-01

      Intrusive luxation in the permanent dentition is an uncommon injury but it is considered one of the most severe types of dental trauma because of the risk for damage to the periodontal ligament, pulp and alveolar bone. Management of intrusive luxation in the permanent dentition is controversial....... The purpose of this study was to evaluate pulp survival and periodontal healing in intrusive luxated permanent teeth in relation to treatment alternatives, degree of intrusion and root development....

  10. Nonstent Combination Interventional Therapy for Treatment of Benign Cicatricial Airway Stenosis.

    Science.gov (United States)

    Qiu, Xiao-Jian; Zhang, Jie; Wang, Ting; Pei, Ying-Hua; Xu, Min

    2015-08-20

    Benign cicatricial airway stenosis (BCAS) is a life-threatening disease. While there are numerous therapies, all have their defects, and stenosis can easily become recurrent. This study aimed to investigate the efficacy and complications of nonstent combination interventional therapy (NSCIT) when used for the treatment of BCAS of different causes and types. This study enrolled a cohort of patients with BCAS resulting from tuberculosis, intubation, tracheotomy, and other origins. The patients were assigned to three groups determined by their type of stenosis: Web-like stenosis, granulation stenosis, and complex stenosis, and all patients received NSCIT. The efficacy and complications of treatment in each group of patients were observed. The Chi-square test, one-factor analysis of variance (ANOVA), and the paired t -test were used to analyze different parameters. The 10 patients with web-like stenosis and six patients with granulation stenosis exhibited durable remission rates of 100%. Among 41 patients with complex stenosis, 36 cases (88%) experienced remission and 29 cases (71%) experienced durable remission. When five patients with airway collapse were eliminated from the analysis, the overall remission rate was 97%. The average treatment durations for patients with web-like stenosis, granulation stenosis, and complex stenosis were 101, 21, and 110 days, respectively, and the average number of treatments was five, two, and five, respectively. NSCIT demonstrated good therapeutic efficacy and was associated with few complications. However, this approach was ineffective for treating patients with airway collapse or malacia.

  11. Transcatheter aortic valve replacement in patients with severe aortic stenosis who are at high risk for surgical complications: summary assessment of the California Technology Assessment Forum.

    Science.gov (United States)

    Tice, Jeffrey A; Sellke, Frank W; Schaff, Hartzell V

    2014-08-01

    The California Technology Assessment Forum is dedicated to assessment and public reporting of syntheses of available data on medical technologies. In this assessment, transcatheter aortic valve replacement (TAVR) was evaluated for patients with severe aortic stenosis (AS) who are at high risk for complications. In this assessment, 5 criteria were used: Regulatory approval, sufficient scientific evidence to allow conclusions on effectiveness, evidence that the technology improves net health outcomes, evidence that the technology is as beneficial as established methods, and availability of the technology outside investigational settings. In this assessment, all 5 criteria were judged to have been met. The primary benefit of TAVR is the ability to treat AS in patients who would otherwise be ineligible for surgical aortic valve replacement. It may also be useful for patients at high surgical risk by potentially reducing periprocedural complications and avoiding the morbidity and recovery from undergoing heart surgery. Potential harms include the need for conversion to an open procedure, perioperative death, myocardial infarction, stroke, bleeding, valve embolization, aortic regurgitation, heart block that requires a permanent pacemaker, renal failure, pulmonary failure, and major vascular complications such as cardiac perforation or arterial dissection. Potential long-term harms include death, stroke, valve failure or clotting, and endocarditis. As highlighted at the February 2012 California Technology Assessment Forum meeting, the dispersion of this technology to new centers across the United States must proceed with careful thought given to training and proctoring multidisciplinary teams to become new centers of excellence. TAVR is a potentially lifesaving procedure that may improve quality of life for patients at high risk for surgical AVR. However, attention needs to be paid to appropriate patient selection, their preoperative evaluation, surgical techniques, and

  12. 29 CFR 2582.8478-3 - Permanent bonding requirements.

    Science.gov (United States)

    2010-07-01

    .... For example, the phrase “every administrator, officer and employee of any employee welfare benefit....8478-3 Labor Regulations Relating to Labor (Continued) EMPLOYEE BENEFITS SECURITY ADMINISTRATION, DEPARTMENT OF LABOR FIDUCIARY RESPONSIBILITY UNDER THE FEDERAL EMPLOYEES' RETIREMENT SYSTEM ACT OF 1986 RULES...

  13. Successful resuscitation from two cardiac arrests in a female patient with critical aortic stenosis, severe mitral regurgitation and coronary artery disease

    Directory of Open Access Journals (Sweden)

    Mijušković Dragan

    2012-01-01

    Full Text Available Introduction. The incidence of sudden cardiac death in patients with severe symptomatic aortic stenosis is up to 34% and resuscitation is described as highly unsuccessful. Case report. A 72-year-old female patient with severe aortic stenosis combined with severe mitral regurgitation and three-vessel coronary artery disease was successfully resuscitated following two in-hospital cardiac arrests. The first cardiac arrest occurred immediately after intraarterial injection of low osmolar iodinated agent during coronary angiography. Angiography revealed 90% occlusion of the proximal left main coronary artery and circumflex branch. The second arrest followed induction of anesthesia. Following successful open-chest resuscitation, aortic valve replacement, mitral valvuloplasty and three-vessel aortocoronary bypass were performed. Postoperative pericardial tamponade required surgical revision. The patient recovered completely. Conclusion. Decision to start resuscitation may be justified in selected patients with critical aortic stenosis, even though cardiopulmonary resuscitation in such cases is generally considered futile.

  14. 3-D analysis of eddy current in permanent magnet of interior permanent magnet motors

    International Nuclear Information System (INIS)

    Kawase, Yoshihiro; Yamaguchi, Tadashi; Fukanaga, Hiromu; Ito, Shokichi

    2002-01-01

    Interior permanent magnet motors are widely used in various fields. However, in high-speed operations, it is important to decrease the eddy current loss in the permanent magnet. In order to decrease the eddy current loss, we propose to divide the permanent magnet. In this paper, we clarified the effect of division of permanent magnet on the eddy current loss using the 3-D finite element method. (Author)

  15. Population-based study of ABCD2 score, carotid stenosis, and atrial fibrillation for early stroke prediction after transient ischemic attack: the North Dublin TIA study.

    LENUS (Irish Health Repository)

    Sheehan, Orla C

    2010-05-01

    Transient ischemic attack (TIA) etiologic data and the ABCD(2) score may improve early stroke risk prediction, but studies are required in population-based cohorts. We investigated the external validity of the ABCD(2) score, carotid stenosis, and atrial fibrillation for prediction of early recurrent stroke after TIA.

  16. Murmur intensity in adult dogs with pulmonic and subaortic stenosis reflects disease severity.

    Science.gov (United States)

    Caivano, D; Dickson, D; Martin, M; Rishniw, M

    2018-03-01

    The aims of this study were to determine whether murmur intensity in adult dogs with pulmonic stenosis or subaortic stenosis reflects echocardiographic disease severity and to determine whether a six-level murmur grading scheme provides clinical advantages over a four-level scheme. In this retrospective multi-investigator study on adult dogs with pulmonic stenosis or subaortic stenosis, murmur intensity was compared to echocardiographically determined pressure gradient across the affected valve. Disease severity, based on pressure gradients, was assessed between sequential murmur grades to identify redundancy in classification. A simplified four-level murmur intensity classification scheme ('soft', 'moderate', 'loud', 'palpable') was evaluated. In total, 284 dogs (153 with pulmonic stenosis, 131 with subaortic stenosis) were included; 55 dogs had soft, 59 had moderate, 72 had loud and 98 had palpable murmurs. 95 dogs had mild stenosis, 46 had moderate stenosis, and 143 had severe stenosis. No dogs with soft murmurs of either pulmonic or subaortic stenosis had transvalvular pressure gradients greater than 50 mmHg. Dogs with loud or palpable murmurs mostly, but not always, had severe stenosis. Stenosis severity increased with increasing murmur intensity. The traditional six-level murmur grading scheme provided no additional clinical information than the four-level descriptive murmur grading scheme. A simplified descriptive four-level murmur grading scheme differentiated stenosis severity without loss of clinical information, compared to the traditional six-level scheme. Soft murmurs in dogs with pulmonic or subaortic stenosis are strongly indicative of mild lesions. Loud or palpable murmurs are strongly suggestive of severe stenosis. © 2017 British Small Animal Veterinary Association.

  17. [Mechanical Shimming Method and Implementation for Permanent Magnet of MRI System].

    Science.gov (United States)

    Xue, Tingqiang; Chen, Jinjun

    2015-03-01

    A mechanical shimming method and device for permanent magnet of MRI system has been developed to meet its stringent homogeneity requirement without time-consuming passive shimming on site, installation and adjustment efficiency has been increased.

  18. Assessment of lumbar spinal canal stenosis by magnetic resonance phlebography

    International Nuclear Information System (INIS)

    Manaka, Masakazu; Komagata, Masashi; Endo, Kenji; Imakiire, Atsuhiro

    2003-01-01

    There is evidence to suggest that cauda equina intermittent claudication is caused by local circulatory disturbances in the cauda equina as well as compression of the cauda equina. We evaluated the role of magnetic resonance phlebography (MRP) in identifying circulatory disturbances of the vertebral venous system in patients with lumbar spinal canal stenosis. Extensive filling defects of the anterior internal vertebral venous plexus were evident in patients with lumbar spinal canal stenosis (n=53), whereas only milder abnormalities were noted in patients with other lumber diseases (n=16) and none in normal subjects (n=13). The extent of the defect on MRP correlated with the time at which intermittent claudication appeared. In patients with lumber spinal canal stenosis, extensive defects of the internal vertebral venous plexus on MRP were noted in the neutral spine position, but the defect diminished with anterior flexion of the spine. This phenomenon correlated closely with the time at which intermittent claudication appeared. Our results highlight the importance of MRP for assessing the underlying mechanism of cauda equina intermittent claudication in patients with lumbar spinal canal stenosis and suggest that congestive venous ischemia is involved in the development of intermittent claudication in these patients. (author)

  19. Laryngotracheal Stenosis: Risk Factors for Tracheostomy Dependence and Dilation Interval

    Science.gov (United States)

    Gadkaree, Shekhar K; Pandian, Vinciya; Best, Simon; Motz, Kevin M; Allen, Clint; Kim, Young; Akst, Lee; Hillel, Alexander T

    2017-02-01

    Objective Laryngotracheal stenosis (LTS) is a fibrotic process that narrows the upper airway and has a significant impact on breathing and phonation. Iatrogenic injury from endotracheal and/or tracheostomy tubes is the most common etiology. This study investigates differences in LTS etiologies as they relate to tracheostomy dependence and dilation interval. Study Design Case series with chart review. Setting Single-center tertiary care facility. Subjects and Methods Review of adult patients with LTS was performed between 2004 and 2015. The association of patient demographics, comorbidities, disease etiology, and treatment modalities with patient outcomes was assessed. Multiple logistic regression analysis and Kaplan-Meier analysis were performed to determine factors associated with tracheostomy dependence and time to second procedure, respectively. Results A total of 262 patients met inclusion criteria. Iatrogenic patients presented with greater stenosis ( P = .023), greater length of stenosis ( P = .004), and stenosis farther from the vocal folds ( P tracheostomy dependence. Nonsmokers, patients without tracheostomy, and idiopathic LTS patients had a significantly longer time to second dilation procedure. Conclusion Iatrogenic LTS presents with a greater disease burden and higher risk of tracheostomy dependence when compared with other etiologies of LTS. Comorbid conditions promoting microvascular injury-including smoking, COPD, and diabetes-were prevalent in the iatrogenic cohort. Changes in hospital practice patterns to promote earlier tracheostomy in high-risk patients could reduce the incidence of LTS.

  20. Treatment of celiac artery stenosis with interventional techniques

    International Nuclear Information System (INIS)

    Wang Maoqiang; Wang Zhijun; Liu Fengyong; Wang Zhongpu

    2005-01-01

    Objective: To present two cases of celiac artery (CA) stenosis treated successfully by interventional technique. Methods: Two patients characterised by chronic upper abdominal pain after eating, associated with weight loss and an epigastric bruit were treated with interventional procedure. The diagnosis was suggested by color Doppler imaging of the celiac axis and confirmed by aortography. One patient possessed the classic triad of median arcuate ligament syndrome (MALS). Arteriosclerosis was found to be responsible for the CA stenosis in another one. The interventional technique consisted of conventional PTA and stent placement in the CA. Results: Abdominal arteriograms in both patients showed severe stenosis (>90%) of CA. The stenotic segments were dilated and stented during the same session. One patient with balloon expandable Palmaz stent placed in the proximal celiac artery, another with 2 wallstents deployed in the CA trunk. The post procedural arteriograms showed good dilation of the lesions with immediate improvement of CA blood flow. Follow-up Doppler ultrasound scans showed normal flow patterns in the CA. Three months after the procedures, their upper gastrointestinal symptoms had resolved and regained body weights. They remained well and free of symptoms, at 16 months and 26 months follow-up, respectively, after the procedure. Conclusions: CA stenosis can successfully be treated with angioplasty and stenting. (authors)

  1. Evaluation of semi-automatic arterial stenosis quantification

    International Nuclear Information System (INIS)

    Hernandez Hoyos, M.; Universite Claude Bernard Lyon 1, 69 - Villeurbanne; Univ. de los Andes, Bogota; Serfaty, J.M.; Douek, P.C.; Universite Claude Bernard Lyon 1, 69 - Villeurbanne; Hopital Cardiovasculaire et Pneumologique L. Pradel, Bron; Maghiar, A.; Mansard, C.; Orkisz, M.; Magnin, I.; Universite Claude Bernard Lyon 1, 69 - Villeurbanne

    2006-01-01

    Object: To assess the accuracy and reproducibility of semi-automatic vessel axis extraction and stenosis quantification in 3D contrast-enhanced Magnetic Resonance Angiography (CE-MRA) of the carotid arteries (CA). Materials and methods: A total of 25 MRA datasets was used: 5 phantoms with known stenoses, and 20 patients (40 CAs) drawn from a multicenter trial database. Maracas software extracted vessel centerlines and quantified the stenoses, based on boundary detection in planes perpendicular to the centerline. Centerline accuracy was visually scored. Semi-automatic measurements were compared with: (1) theoretical phantom morphometric values, and (2) stenosis degrees evaluated by two independent radiologists. Results: Exploitable centerlines were obtained in 97% of CA and in all phantoms. In phantoms, the software achieved a better agreement with theoretic stenosis degrees (weighted kappa Κ W = 0.91) than the radiologists (Κ W = 0.69). In patients, agreement between software and radiologists varied from Κ W =0.67 to 0.90. In both, Maracas was substantially more reproducible than the readers. Mean operating time was within 1 min/ CA. Conclusion: Maracas software generates accurate 3D centerlines of vascular segments with minimum user intervention. Semi-automatic quantification of CA stenosis is also accurate, except in very severe stenoses that cannot be segmented. It substantially reduces the inter-observer variability. (orig.)

  2. Conservative Treatment for Cystic Duct Stenosis in a Child

    Directory of Open Access Journals (Sweden)

    Marco Gasparetto

    2013-01-01

    Full Text Available Introduction. Few cases of common bile duct stenosis have been reported in the literature, and observations of strictures in the cystic duct are even more rare. Surgical cholecystectomy is the treatment needed in most cases of gallbladder hydrops. This paper describes the diagnosis and successful medical treatment of a rare pediatric case of cystic duct stenosis and gallbladder hydrops. Case Report. A formerly healthy one-year-old girl was admitted with colicky abdominal pain. Blood tests were normal, except for an increase in transaminases. Abdominal ultrasound excluded intestinal intussusception and identified a distended gallbladder with biliary sludge. MR cholangiography revealed a dilated gallbladder containing bile sediment and no detectable cystic duct, while the rest of the intra- and extrahepatic biliary tree and hepatic parenchyma were normal. This evidence was consistent with gallbladder hydrops associated with cystic duct stenosis. The baby was treated with i.v. hydration, corticosteroids, antibiotics, and ursodeoxycholic acid. Her general condition rapidly improved, with no further episodes of abdominal pain and normalization of liver enzymes. This allowed to avoid cholecystectomy, and the child is well 1.5 years after diagnosis. Conclusions. Although cholecystectomy is usually necessary in case of gallbladder hydrops, our experience suggests that surgical procedures can be avoided when the distension is caused by a cystic duct stenosis.

  3. Operated herniated disk and lumbar spinal stenosis in Togolese ...

    African Journals Online (AJOL)

    Objective: To determine the anatomical aspects and results of surgical treatment of herniated disk and lumbar spinal stenosis observed in the Rheumatology unit of CHU SO of Lomé. Patients and methods: This was a transversal study conducted on a series of patients cases admitted to the Rheumatology Unit of CHU SO of ...

  4. Management of Renal Artery Stenosis - an Update | Alhadad ...

    African Journals Online (AJOL)

    The role of the renal vasculature in eliciting renovascular hypertension (RVH) was established in 1934, when Goldblatt et al. [1] in a classical experimental study demonstrated that partial obstruction of the renal artery increased mean arterial blood pressure (BP). The pathophysiology of renal artery stenosis (RAS) is ...

  5. Imaging Modalities for Cervical Spondylotic Stenosis and Myelopathy

    Directory of Open Access Journals (Sweden)

    C. Green

    2012-01-01

    Full Text Available Cervical spondylosis is a spectrum of pathology presenting as neck pain, radiculopathy, and myelopathy or all in combination. Diagnostic imaging is essential to diagnosis and preoperative planning. We discuss the modalities of imaging in common practice. We examine the use of imaging to differentiate among central, subarticular, and lateral stenosis and in the assessment of myelopathy.

  6. An unusual complication of stenosis of a colostomy.

    Science.gov (United States)

    Haiart, D. C.

    1985-01-01

    A patient is reported in whom stenosis of the colostomy was responsible for perforation of the colostomy by a bone. Necrotizing gangrene of the abdominal wall developed. The management of the resulting full thickness defect of the abdominal wall is described. Images Figure 1 Figure 2 PMID:4011545

  7. Proctitis and rectal stenosis induced by nonsteroidal antiinflammatory suppositories

    NARCIS (Netherlands)

    D'Haens, G.; Breysem, Y.; Rutgeerts, P.; van Besien, B.; Geboes, K.; Ponette, E.; Vantrappen, G.

    1993-01-01

    Anorectal ulceration eventually leading to rectal stenosis was observed in 10 patients who abused analgetic suppositories containing acetylsalicylic acid, acetaminophen, and codeine. Most patients were middle-aged women with a neurotic or psychiatric background. Perianal skin lesions were present in

  8. Outcome of Carotid Artery Stenting for Radiation-Induced Stenosis

    International Nuclear Information System (INIS)

    Dorresteijn, Lucille; Vogels, Oscar; Leeuw, Frank-Erik de; Vos, Jan-Albert; Christiaans, Marleen H.; Ackerstaff, Rob; Kappelle, Arnoud C.

    2010-01-01

    Purpose: Patients who have been irradiated at the neck have an increased risk of symptomatic stenosis of the carotid artery during follow-up. Carotid angioplasty and stenting (CAS) can be a preferable alternative treatment to carotid endarterectomy, which is associated with increased operative risks in these patients. Methods and Materials: We performed a prospective cohort study of 24 previously irradiated patients who underwent CAS for symptomatic carotid stenosis. We assessed periprocedural and nonprocedural events including transient ischemic attack (TIA), nondisabling stroke, disabling stoke, and death. Patency rates were evaluated on duplex ultrasound scans. Restenosis was defined as a stenosis of >50% at the stent location. Results: Periprocedural TIA rate was 8%, and periprocedural stroke (nondisabling) occurred in 4% of patients. After a mean follow-up of 3.3 years (range, 0.3-11.0 years), only one ipsilateral incident event (TIA) had occurred (4%). In 12% of patients, a contralateral incident event was present: one TIA (4%) and two strokes (12%, two disabling strokes). Restenosis was apparent in 17%, 33%, and 42% at 3, 12, and 24 months, respectively, although none of the patients with restenosed vessels became symptomatic. The length of the irradiation to CAS interval proved the only significant risk factor for restenosis. Conclusions: The results of CAS for radiation-induced carotid stenosis are favorable in terms of recurrence of cerebrovascular events at the CAS site.

  9. Aortic valve replacement for aortic stenosis caused by alkaptonuria.

    Science.gov (United States)

    Hiroyoshi, Junko; Saito, Aya; Panthee, Nirmal; Imai, Yasushi; Kawashima, Dai; Motomura, Noboru; Ono, Minoru

    2013-03-01

    We report a case of aortic stenosis associated with ochronosis in a 70-year-old man who underwent biologic aortic valve replacement. Intraoperative findings included ochronosis of a severely calcified pigmented aortic valve along with pigmentation of the intima of the aorta. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Alkaptonuria Presenting with Impressive Osteoarticular Changes and Severe Aortic Stenosis.

    Science.gov (United States)

    Roca, Bernardino; Roca, Manuel; Monferrer, Raquel

    2016-03-01

    Alkaptonuria, or ochronosis, a rare autosomal recessive metabolic disorder, causes an excess of homogentisic acid that results in dark pigmentation, calcification, and inflammation of cartilaginous and other tissues. Cardiovascular complications are also typical of the disease. We report the case of a 78-year-old male who presented with impressive osteoarticular changes and aortic stenosis associated with alkaptonuria.

  11. Management of complex pediatric laryngotracheal stenosis with skin graft reconstruction.

    Science.gov (United States)

    Bowe, Sarah N; Wentland, Carissa J; Sandhu, G S; Hartnick, Christopher J

    2018-05-01

    For pediatric patients with laryngotracheal stenosis, the ultimate goal is creation of a safe, functional airway. Unfortunately, wound healing in a hollow structure can complicate repair attempts, leading to restenosis. Herein, we present our experience using skin-grafting techniques in two complex pediatric laryngotracheal stenosis cases, leading to successful decannulation or speech production. A chart review was performed examining the evaluation and management of two pediatric patients with laryngotracheal stenosis despite prior reconstructive attempts. Patient history, bronchoscopic evaluation, intra-operative technique, post-operative management, treatment outcomes, and complications were noted. Harvesting and preparation of the split-thickness skin grafts (STSG) proceeded in a similar manner for each case. Stenting material varied based on the clinical scenario. Using this technique, our patient with a Type 3 glottic web achieved substantial improvement in exercise tolerance, as well as vocal strength and quality. In addition, our aphonic patient could vocalize for the first time since her laryngotracheal injury. Temporary endoluminal stenting with skin graft lining can reproduce epithelial continuity and provide "biological inhibition" to enhance the wound healing process. When previous reconstructive efforts have failed, use of STSG can be considered in the management of complex pediatric laryngotracheal stenosis. Copyright © 2018. Published by Elsevier B.V.

  12. Diagnostic workup in carotid stenosis - a neurologist's perspective

    International Nuclear Information System (INIS)

    Rosenkranz, Michael; Gerloff, Christian

    2010-01-01

    Carotid artery stenosis is associated with the risk of stroke, myocardial infarction, and vascular death. In selected patients, revascularization of carotid narrowing by endarterectomy may reduce the risk of stroke distal to the stenosis. Carotid artery stenting has evolved as a potential alternative to endarterectomy. Four randomized clinical trials comparing safety and efficacy of endarterectomy versus stenting of symptomatic carotid stenosis have been published in recent years, but there remains some uncertainty about the implications of these trials for clinical routine. Both carotid stenting and endarterectomy are based on different treatment strategies which may result in different specific risk factors associated with each procedure. Hence, the procedural risk of either modality varies not only with the skills of the surgeon or the interventionalist but may depend on patient characteristics. It appears that the most important question is not whether one revascularization modality is superior but for which patient one modality is better than the other. A comprehensive diagnostic workup of patients with carotid stenosis based on a broad panel of covariates that affect the risk of vascular events may improve selection of patients for carotid revascularization and may help to decide for whom one revascularization modality is likely to be better than the other. (orig.)

  13. Metallic stent for the treatment of iliac arterial stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Hyung; Chung, Jin Wook; Han, Joon Koo; Suh, Chul Soo; Yoo, Jae Wook; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of); Song, Chi Sung [Seoul City Boramae Hospital, Seoul (Korea, Republic of)

    1993-07-15

    In order to study the clinical efficacy of the metallic stent of the treatment of iliac arterial stenosis, the clinical and arteriographic findings of the 8 patients were retrospectively reviewed. All 8 patients were males with an age of 51 to 79. The Fontaine class for the functional status of lower extremities was II in 4 patients, III in 3 patents and IV in 1 patient. Self expandable Gianturco stent was inserted of in 7 iliac arteries and balloon expandable Palmaz stent was inserted in 2 iliac arteries in the 8 patients. The indications for the metallic stent application were localized dissection with significant residual stenosis in 6 sites, recoiling due to calcification in one case and eccentricity of the stenosislesionin 2 sites. The deployment of the metallic stent was successful in all the cases to maintain the patency of iliac arteries with residual stenosis less than 30%. The Fontaine class was improved to 1 in 6 patients, IIa in 1 patient and IIb in another one. During the follow up period of 3 to 14 month, none except one developed recurrence of the symptom. On the basis of our experience, we believe that metallic stent is safe and effective for the treatment of iliac arterial stenosis. However, we think that it is a complementary measure to the percutaneous transluminal angioplasty. The comparative study between different types of metallic stent and the long term effect should be investigated further.

  14. Role of Montgomery T-tube stent for laryngotracheal stenosis.

    Science.gov (United States)

    Prasanna Kumar, Saravanam; Ravikumar, Arunachalam; Senthil, Kannan; Somu, Lakshman; Nazrin, Mohd Ismail

    2014-04-01

    To identify the indications, complications and outcome of patients of LTS managed with Montgomery T-tube stenting and review the current literature about the role of stenting in LTS. Retrospective chart reviews of 39 patients of laryngotracheal stenosis managed by T-tube stenting for temporary or definitive treatment during the period 2004-2011 were considered. The data on indications for stenting, type of stent, problems/complications of stenting, duration of stenting, additional intervention and outcome of management were collected, tabulated and analyzed. Of the 51 cases of laryngotracheal stenosis 39 patients were treated by Montgomery T-tube stenting. There was no mortality associated with the procedure or stenting. 82% of the patients were successfully decannulated. The problems and complications encountered were crusting within the tube in 44% and granulation at the subglottis in 33%. Two patients had complication due to T-tube itself: One patient developed tracheomalacia and the other had stenosis at both ends of the T-tube. Stenting still has a role in management of inoperable or in some deadlock situations where resection anastomosis is not feasible. It is easier to introduce the stent and to maintain it. Complications are minor and can be managed easily. It is safe for long term use. We emphasize that the treating surgeon needs to use prudence while treating stenosis using stents. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. Congenital bicuspid stenosis with left ventricular hypoplasia in a kitten.

    Science.gov (United States)

    van Nie, C J; van Messel, M A; Straatman, T J

    1980-01-15

    Congenital bicuspid stenosis with left ventricular hypoplasia was diagnosed in a kitten. Clinical weakness, dyspnoea and marked cardiomegaly (X rays) were related to postmortem findings. The cardiomegaly had resulted from an enlargement of the left auricular appendage. It is supposed the cardiomegaly developed after the closing of the foramen ovale.

  16. Design of permanent magnetic solenoids for REGAE

    Energy Technology Data Exchange (ETDEWEB)

    Gehrke, Tim

    2013-10-15

    The Relativistic Electron Gun for Atomic Exploration (REGAE) is a small linear accelerator at DESY in Hamburg, which produces short, low emittance electron bunches. It is originally designed and built for ultrafast electron diffraction (UED) within the framework of the Center for Free-Electron Laser Science (CFEL). Additionally, two future experiments are planned at REGAE. First, an external injection experiment for Laser Wakefield Acceleration (LWA) will be performed in the framework of the LAOLA collaboration (LAboratory fOr Laser- and beam-driven plasma Acceleration). This experiment will provide a method for the reconstruction of the electric field distribution within a linear plasma wakefield. Second, a time resolving high energy Transmission Electron Microscope (TEM) will be implemented. Among others it is designed to allow for living cell imaging. Both experiments require strong focusing magnets inside the new target chamber at REGAE. Permanent magnetic solenoids (PMSs) can provide the needed focusing strength due to their enormous surface current density, while having compact dimensions at the same time. The present thesis deals with the design of such strong focusing PMSs. Since short and strong solenoids, as required for REGAE, exhibit a distinct non-linearity, the induced emittance growth is relatively large. This emittance growth is investigated and minimized for different set-ups with axially and radially magnetized annular magnets. Furthermore a magnetic shielding is developed. Together with a mechanical lifting system it assures that magnetic leakage fields do not disturb experiments, where the PMSs are removed from the beamline.

  17. Design of permanent magnetic solenoids for REGAE

    International Nuclear Information System (INIS)

    Gehrke, Tim

    2013-10-01

    The Relativistic Electron Gun for Atomic Exploration (REGAE) is a small linear accelerator at DESY in Hamburg, which produces short, low emittance electron bunches. It is originally designed and built for ultrafast electron diffraction (UED) within the framework of the Center for Free-Electron Laser Science (CFEL). Additionally, two future experiments are planned at REGAE. First, an external injection experiment for Laser Wakefield Acceleration (LWA) will be performed in the framework of the LAOLA collaboration (LAboratory fOr Laser- and beam-driven plasma Acceleration). This experiment will provide a method for the reconstruction of the electric field distribution within a linear plasma wakefield. Second, a time resolving high energy Transmission Electron Microscope (TEM) will be implemented. Among others it is designed to allow for living cell imaging. Both experiments require strong focusing magnets inside the new target chamber at REGAE. Permanent magnetic solenoids (PMSs) can provide the needed focusing strength due to their enormous surface current density, while having compact dimensions at the same time. The present thesis deals with the design of such strong focusing PMSs. Since short and strong solenoids, as required for REGAE, exhibit a distinct non-linearity, the induced emittance growth is relatively large. This emittance growth is investigated and minimized for different set-ups with axially and radially magnetized annular magnets. Furthermore a magnetic shielding is developed. Together with a mechanical lifting system it assures that magnetic leakage fields do not disturb experiments, where the PMSs are removed from the beamline.

  18. Long-term tolerance of airway silicone stent in patients with post-tuberculosis tracheobronchial stenosis.

    Science.gov (United States)

    Verma, Akash; Um, Sang-Won; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung; Kim, Hojoong

    2012-01-01

    Surgery is a well-recognized modality of treatment for benign tracheobronchial stenosis. However, in some benign disease groups, such as tuberculosis, sarcoidosis, war gas exposure, and inhalation burns, multiplicity of involvement or long length of stenosed segment heightens surgical challenge. We investigated the outcomes and long-term tolerability of the Natural stent (N-stent) in such patients with post-tuberculosis tracheobronchial stenosis. A retrospective review was done for 17 patients who underwent silicone stenting (N-stent) for post-tuberculosis tracheobronchial stenosis during January 2000-December 2003 but needed persistent stent placement and still require the stent. Significant increase in the ratio of forced expiratory volume in 1 second (FEV1) to forced vital capacity (FVC), expressed as FEV1%, as well as in forced percentual vital capacity (FVC%) (Δ24% and Δ11%, respectively) in the short term and sustained increase in the FEV1% and FVC% (Δ26.5% and Δ16.5%, respectively) in the long term were noted at a median (range) interval of 1 (0.5-72) month and 72 (12-114) months, respectively, along with symptomatic relief. No procedure-related death occurred. Stent-related late complications included granulation tissue formation (76%), migration (70%), and mucostasis (17%). The median duration for which N-stents were tolerated was 7.9 (range, 3-11) years. N-stents are well-tolerated for a prolonged period. Stent-related complications occur, but are easily managed. These results might carry medical implications for those who have airway lesions difficult to correct surgically.

  19. Safety and Efficacy of a Fully Covered Self-Expandable Metallic Stent in Benign Airway Stenosis.

    Science.gov (United States)

    Fortin, Marc; Lacasse, Yves; Elharrar, Xavier; Tazi-Mezalek, Rachid; Laroumagne, Sophie; Guinde, Julien; Astoul, Philippe; Dutau, Hervé

    2017-01-01

    The use of self-expandable metallic stents (SEMS) in benign airway disease was the object of a boxed warning from the United States Food and Drug Administration in 2005 due to the risk of stent-related complications and difficulties associated with their removal. Third-generation fully covered SEMS have been commercialized since this warning and theoretically should not present the same difficulties associated with removal as they cannot become embedded in the airway mucosa. We aimed to examine the safety and efficacy of a specific third-generation SEMS, the Silmet stent. We reviewed the records of all patients treated for benign airway stenosis with third-generation Silmet SEMS from January 2011 to December 2015 at the North Hospital of Marseilles, France. Forty SEMS were inserted in 30 patients over this period. Twenty (50.0%) stents were removed because of stent-related complications after a median of 77.0 ± 96.6 days (migration 32.5%, granulation tissue formation 7.5%, subjective intolerance 5.0%, mucus plugging 2.5%, laryngeal edema 2.5%). There were no cases of stent-related mortality. All complications were managed successfully endoscopically. Thirty-six stents (90.0%) were removed successfully after a median of 122.0 ± 113.2 days without any complications. The clinical success rate of stent treatment was 40.7%. Third-generation SEMS are a safe treatment option for complex benign airway stenosis, but complications requiring stent removal are frequent. Further studies are needed to compare the performance of third-generation SEMS and silicone stents in benign airway stenosis. © 2017 S. Karger AG, Basel.

  20. Unilateral Approach for Bilateral Decompression of Lumbar Spinal Stenosis: A Minimal Invasive Surgery

    International Nuclear Information System (INIS)

    Usman, M.; Ali, M.; Khanzada, K.; Haq, N.U.; Aman, R.; Ali, M.

    2013-01-01

    Objective: To assess the feasibility and efficacy of a novel, minimally invasive spinal surgery technique for the correction of lumbar spinal stenosis involving unilateral approach for bilateral decompression. Study Design: Cross-sectional observational study. Place and Duration of Study: Neurosurgery Department of PGMI, Lady Reading Hospital, Peshawar, from January to December 2010. Methodology: A total of 60 patients with lumbar stenosis were randomly assigned to undergo either a conventional laminectomy (30 patients, Group A), or a unilateral approach (30 patients, Group B). Clinical outcomes was measured using the scale of Finneson and Cooper. All the data was collected by using a proforma and different parameters were assessed for a minimum follow-up period of three months. Data was analyzed by descriptive statistics using SPSS software version 17. Results: Adequate decompression was achieved in all patients. Compared with patients in the conventional laminectomy group, patients who received the novel procedure (unilateral approach) had a reduced mean duration of hospital stay, a faster recovery rate and majority of the patients (88.33%) had an excellent to fair operative result according to the Finneson and Cooper scale. Five major complications occurred in all patient groups, 2 patients had unintended dural rent and 2 wound dehiscence each and fifth patient had worsening of symptoms. There was no mortality in the series. Conclusion: The ultimate goal of the unilateral approach to treat lumbar spinal stenosis is to achieve adequate decompression of the neural elements. An additional benefit of a minimally invasive approach is adequate preservation of vertebral stability, as it requires only minimal muscle trauma, preservation of supraspinous/intraspinous ligament complex and spinous process, therefore, allows early mobilization. This also shortens the hospital stay, reduces postoperative back pain, and leads to satisfactory outcome. (author)

  1. Long-term results of percutaneous balloon valvuloplasty in pulmonary valve stenosis in the pediatric population.

    Science.gov (United States)

    Merino-Ingelmo, Raquel; Santos-de Soto, José; Coserria-Sánchez, Félix; Descalzo-Señoran, Alfonso; Valverde-Pérez, Israel

    2014-05-01

    Percutaneous pulmonary valvuloplasty is the preferred interventional procedure for pulmonary valve stenosis. The aim of this study was to evaluate the effectiveness of this technique, assess the factors leading to its success, and determine the long-term results in the pediatric population. The study included 53 patients with pulmonary valve stenosis undergoing percutaneous balloon valvuloplasty between December 1985 and December 2000. Right ventricular size and functional echocardiographic parameters, such as pulmonary regurgitation and residual transvalvular gradient, were assessed during long-term follow-up. Peak-to-peak transvalvular gradient decreased from 74 mmHg [interquartile range, 65-100 mmHg] to 20 mmHg [interquartile range, 14-34 mmHg]. The procedure was unsuccessful in 2 patients (3.77%). The immediate success rate was 73.58%. Follow-up ranged from 10 years to 24 years (median, 15 years). During follow-up, all patients developed late pulmonary regurgitation which was assessed as grade II in 58.4% and grade III in 31.2%. There was only 1 case of long-term restenosis (2.1%). Severe right ventricular dilatation was observed in 27.1% of the patients. None of the patients developed significant right ventricular dysfunction. Pulmonary valve replacement was not required in any of the patients. Percutaneous balloon valvuloplasty is an effective technique in the treatment of pulmonary valve stenosis with good long-term results. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  2. Contemporary carotid imaging: from degree of stenosis to plaque vulnerability.

    Science.gov (United States)

    Brinjikji, Waleed; Huston, John; Rabinstein, Alejandro A; Kim, Gyeong-Moon; Lerman, Amir; Lanzino, Giuseppe

    2016-01-01

    Carotid artery stenosis is a well-established risk factor of ischemic stroke, contributing to up to 10%-20% of strokes or transient ischemic attacks. Many clinical trials over the last 20 years have used measurements of carotid artery stenosis as a means to risk stratify patients. However, with improvements in vascular imaging techniques such as CT angiography and MR angiography, ultrasonography, and PET/CT, it is now possible to risk stratify patients, not just on the degree of carotid artery stenosis but also on how vulnerable the plaque is to rupture, resulting in ischemic stroke. These imaging techniques are ushering in an emerging paradigm shift that allows for risk stratifications based on the presence of imaging features such as intraplaque hemorrhage (IPH), plaque ulceration, plaque neovascularity, fibrous cap thickness, and presence of a lipid-rich necrotic core (LRNC). It is important for the neurosurgeon to be aware of these new imaging techniques that allow for improved patient risk stratification and outcomes. For example, a patient with a low-grade stenosis but an ulcerated plaque may benefit more from a revascularization procedure than a patient with a stable 70% asymptomatic stenosis with a thick fibrous cap. This review summarizes the current state-of-the-art advances in carotid plaque imaging. Currently, MRI is the gold standard in carotid plaque imaging, with its high resolution and high sensitivity for identifying IPH, ulceration, LRNC, and inflammation. However, MRI is limited due to time constraints. CT also allows for high-resolution imaging and can accurately detect ulceration and calcification, but cannot reliably differentiate LRNC from IPH. PET/CT is an effective technique to identify active inflammation within the plaque, but it does not allow for assessment of anatomy, ulceration, IPH, or LRNC. Ultrasonography, with the aid of contrast enhancement, is a cost-effective technique to assess plaque morphology and characteristics, but it is

  3. Corporate Policies with Permanent and Transitory Shocks

    NARCIS (Netherlands)

    J-P. Decamps (Jean-Paul); S. Gryglewicz (Sebastian); E. Morellec (Erwan); S. Villeneuve (Stephane)

    2016-01-01

    textabstractWe model the financing, cash holdings, and hedging policies of a firm facing financing frictions and subject to permanent and transitory cash flow shocks. We show that permanent and transitory shocks generate distinct, sometimes opposite, effects on corporate policies and use the model

  4. OAS :: Authorities : Permanent Representatives to the OAS

    Science.gov (United States)

    Rights Actions against Corruption C Children Civil Registry Civil Society Contact Us Culture Cyber Representative of Belize Diego Pary Rodríguez Bolivia Diego Pary Rodríguez Ambassador, Permanent Representative of Bolivia José Luiz Machado Brazil José Luiz Machado e Costa Ambassador, Permanent Representative

  5. Guidelines for removing permanent makeup

    Directory of Open Access Journals (Sweden)

    C.Bettina Rümmelein

    2016-09-01

    Full Text Available Permanent makeup (PMU is a frequently implemented cosmetic procedure performed by beauticians. From a technical point, PMU is considered a facial tattoo. Failed procedures or a change of mind can lead to the desire for removal. The purpose of this retrospective evaluation of patients who came to the clinic with the desire to remove PMU between 2011 and 2015 was to explore the problems, side effects, and results in order to define treatment guidelines for other doctors. We evaluated 87 individual cases in total. In treatable cases, i.e. 52 out of the 87 cases, laser treatments were performed using a nanosecond Q-switched neodymium-doped yttrium aluminium garnet (Nd:YAG laser. It takes between 1-12 treatments to remove the PMU. In three cases, the colour of the PMU could not be removed by laser and remained after the treatment. In two cases, laser treatment had to be terminated due to colour changes towards the green-blue spectrum. Before PMU removal, laser test shots are urgently recommended as unforeseeable colour changes can cause severe aesthetically unpleasant results. Covered up PMU (skin colour is particularly susceptible to changes in colour. Heat-induced shrinking of the eye area can cause an ectropium. Surgical solutions also have to be taken into consideration. The use of proper eye protection with intraocular eye shields is mandatory. This article is an attempt to set up some guidelines for the treatment of PMU removal.

  6. Dysplastic pulmonary valve stenosis associated with unilateral absent first metacarpal: A rare association

    Directory of Open Access Journals (Sweden)

    Ashwin Kodliwadmath

    2017-08-01

    Full Text Available Context: Dysplastic pulmonary valve stenosis is a less common variety of valvular pulmonary stenosis. It is known to be part of Noonan syndrome. Bony hand anomalies in patients of pulmonary stenosis are very rare. Case report: A 50-year-old lady, with no significant past history, presented with slowly progressive breathlessness and fatigue, and had progressed from NYHA class 1 to 2 over 2 years. She had unilateral absent first metacarpal and diagnosed on workup to have dysplastic pulmonary valve stenosis and was treated with balloon valvuloplasty. Conclusion: Dysplastic pulmonary valve stenosis can rarely be associated with bony hand anomalies like absent first metacarpal.

  7. Herpes zoster sciatica mimicking lumbar canal stenosis: a case report.

    Science.gov (United States)

    Koda, Masao; Mannoji, Chikato; Oikawa, Makiko; Murakami, Masazumi; Okamoto, Yuzuru; Kon, Tamiyo; Okawa, Akihiko; Ikeda, Osamu; Yamazaki, Masashi; Furuya, Takeo

    2015-07-29

    Symptom of herpes zoster is sometimes difficult to distinguish from sciatica induced by spinal diseases, including lumbar disc herniation and spinal canal stenosis. Here we report a case of sciatica mimicking lumbar canal stenosis. A 74-year-old Chinese male patient visited our hospital for left-sided sciatic pain upon standing or walking for 5 min of approximately 1 month's duration. At the first visit to our hospital, there were no skin lesions. A magnetic resonance imaging showed spinal canal stenosis between the 4th and 5th lumbar spine. Thus, we diagnosed the patient with sciatica induced by spinal canal stenosis. We considered decompression surgery for the stenosis of 4th and 5th lumbar spine because conservative therapy failed to relieve the patient's symptom. At that time, the patient complained of a skin rash involving his left foot for several days. A vesicular rash and erythema were observed on the dorsal and plantar surfaces of the great toe and lateral malleolus. The patient was diagnosed with herpes zoster in the left 5th lumbar spinal nerve area based on clinical findings, including the characteristics of the pain and vesicular rash and erythema in the 5th lumbar spinal dermatome. The patient was treated with famciclovir (1,500 mg/day) and non-steroidal anti-inflammatory drugs. After 1 week of medication, the skin rash resolved and pain relief was obtained. In conclusion, spinal surgeons should keep in mind herpes zoster infection as one of the possible differential diagnoses of sciatica, even if there is no typical skin rash.

  8. [Self-expanding nitinol stents in proximal tracheal stenosis].

    Science.gov (United States)

    Hafner, B; Mann, W; Heussel, C P; Scherhag, A; Schlegel, J; Kauczor, H U

    2000-03-01

    The use of silicone- or metal stents in stenosis of the distal trachea and the bronchial system is a customary procedure [1-4], for example after tumor invasion or cicatricial stenosis after transplantation. In the proximal part of the trachea, on smaller, short and soft strictures we try to stabilise the trachea by the implantation of rings. Other methods are tracheal plasty or transverse tracheal resectomy [5-7]. In the case of longer or nearer subglottal stenoses the positioning of self-expanding nitinol stents has proven a simple, gentle and well-tolerated alternative procedure even in very serious disorders [1, 8, 9]. These stents can be placed in short narcosis under endoscopic control without great strain on the patient. We placed nitinol-stents in the proximal part of the trachea in eleven cases. In five cases dyspnoea caused by a tracheal collapse improved. In two further cases a tracheal stenosis with massive granulation tissue and cicatricial pull under an inlaid tracheal cannula was removed and the tracheostoma was closed. In four cases a solid, scarred and cartilaginous stenosis in the area of the cricoid and the upper tracheal rings was widened with laser and later on stented. Over an observation time of two years no complications showed safe one case in which a directly postoperative dislocation was repositioned quickly. The patients live without restrictions through the tracheal stenosis or a tracheostoma. In the best possible case epithelialization over the metal meshes develops so that a nearly normal mucus transportation is possible [1, 10-12].

  9. Irradiation inhibits vascular anastomotic stenosis in a canine model

    International Nuclear Information System (INIS)

    Saito, Takeshi; Iguchi, Atsushi; Tabayashi, Koichi

    2009-01-01

    The graft patency rate after coronary artery bypass grafting (CABG) correlates with anastomotic stenosis. Intracoronary radiation therapy is effective for preventing restenosis after percutaneous coronary intervention (PCI). We postulated that intracoronary radiation therapy could prevent anastomotic stenosis and tested this hypothesis in an animal model. Femoral arteries and veins of beagle dogs were harvested, and composite arterioarterial and arteriovenous grafts were prepared. After external irradiation of the anastomotic sites, these composite grafts were transplanted into femoral arteries. Histomorphometric and immunohistological analyses of the anastomotic sites were performed. The study groups consisted of controls and animals exposed to 10 Gy, 20 Gy, and 30 Gy (n=5, in each group). In the artery graft model, the ratio of negative remodeling was significantly increased in all groups exposed to ≥10 Gy. The ratio of neointimal hyperplasia was significantly decreased in all groups exposed to ≥10 Gy. Cell density of anti-α-actin antibody-positive cells and anti-proliferating cell nuclear antigen (PCNA) antibody-positive cells was highest in the adventitial layer, and the density decreased as the dosage increased. Experimental results were almost the same in the vein graft models as in the artery graft models. With double immunohistostaining, the anti-PCNA antibody-positive cells expressed α-actin. Irradiation can inhibit anastomotic stenosis in a canine model. Adventitia is a factor in the creation of stenosis, and irradiation appears to target the adventitia. We speculate that there might be a possible role for intracoronary irradiation in the future to prevent anastomotic stenosis. (author)

  10. Permanent magnet with MgB{sub 2} bulk superconductor

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Akiyasu, E-mail: yamamoto@appchem.t.u-tokyo.ac.jp [The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656 (Japan); JST-PRESTO, 4-1-8 Honcho, Kawaguchi, Saitama 332-0012 (Japan); Ishihara, Atsushi; Tomita, Masaru [Railway Technical Research Institute, 2-8-38 Hikari, Kokubunji, Tokyo 185-8540 (Japan); Kishio, Kohji [The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656 (Japan)

    2014-07-21

    Superconductors with persistent zero-resistance currents serve as permanent magnets for high-field applications requiring a strong and stable magnetic field, such as magnetic resonance imaging. The recent global helium shortage has quickened research into high-temperature superconductors (HTSs)—materials that can be used without conventional liquid-helium cooling to 4.2 K. Herein, we demonstrate that 40-K-class metallic HTS magnesium diboride (MgB{sub 2}) makes an excellent permanent bulk magnet, maintaining 3 T at 20 K for 1 week with an extremely high stability (<0.1 ppm/h). The magnetic field trapped in this magnet is uniformly distributed, as for single-crystalline neodymium-iron-boron. Magnetic hysteresis loop of the MgB{sub 2} permanent bulk magnet was determined. Because MgB{sub 2} is a simple-binary-line compound that does not contain rare-earth metals, polycrystalline bulk material can be industrially fabricated at low cost and with high yield to serve as strong magnets that are compatible with conventional compact cryocoolers, making MgB{sub 2} bulks promising for the next generation of Tesla-class permanent-magnet applications.

  11. Permanent Magnetic System Design for the Wall-Climbing Robot

    Directory of Open Access Journals (Sweden)

    W. Shen

    2006-01-01

    Full Text Available This paper presents the design and analysis of the permanent magnetic system for a wall-climbing robot with permanent magnetic tracks. Based on the behaviour of gecko lizards, the architecture of the robot was designed and built, including the structure of the adhesion mechanism, the mechanical architecture and the anti-toppling mechanism. The permanent magnetic adhesion mechanism and the tracked locomotion mechanism were employed in this kind of wall-climbing robot. Through static and dynamic force analysis of the robot under different situations, design requirements for the adhesion mechanism were derived. Two different types of structures were put forward for the permanent magnetic units and are further discussed in this paper. These two types of structures are also analysed in detail. In addition, a finite-element method was used to verify the results of magnetic units. Finally, two wall-climbing robots, equipped with different magnetic systems described previously, are explained and their applications are discussed in this paper.

  12. Design and analysis of tubular permanent magnet linear wave generator.

    Science.gov (United States)

    Si, Jikai; Feng, Haichao; Su, Peng; Zhang, Lufeng

    2014-01-01

    Due to the lack of mature design program for the tubular permanent magnet linear wave generator (TPMLWG) and poor sinusoidal characteristics of the air gap flux density for the traditional surface-mounted TPMLWG, a design method and a new secondary structure of TPMLWG are proposed. An equivalent mathematical model of TPMLWG is established to adopt the transformation relationship between the linear velocity of permanent magnet rotary generator and the operating speed of TPMLWG, to determine the structure parameters of the TPMLWG. The new secondary structure of the TPMLWG contains surface-mounted permanent magnets and the interior permanent magnets, which form a series-parallel hybrid magnetic circuit, and their reasonable structure parameters are designed to get the optimum pole-arc coefficient. The electromagnetic field and temperature field of TPMLWG are analyzed using finite element method. It can be included that the sinusoidal characteristics of air gap flux density of the new secondary structure TPMLWG are improved, the cogging force as well as mechanical vibration is reduced in the process of operation, and the stable temperature rise of generator meets the design requirements when adopting the new secondary structure of the TPMLWG.

  13. Design and Analysis of Tubular Permanent Magnet Linear Wave Generator

    Directory of Open Access Journals (Sweden)

    Jikai Si

    2014-01-01

    Full Text Available Due to the lack of mature design program for the tubular permanent magnet linear wave generator (TPMLWG and poor sinusoidal characteristics of the air gap flux density for the traditional surface-mounted TPMLWG, a design method and a new secondary structure of TPMLWG are proposed. An equivalent mathematical model of TPMLWG is established to adopt the transformation relationship between the linear velocity of permanent magnet rotary generator and the operating speed of TPMLWG, to determine the structure parameters of the TPMLWG. The new secondary structure of the TPMLWG contains surface-mounted permanent magnets and the interior permanent magnets, which form a series-parallel hybrid magnetic circuit, and their reasonable structure parameters are designed to get the optimum pole-arc coefficient. The electromagnetic field and temperature field of TPMLWG are analyzed using finite element method. It can be included that the sinusoidal characteristics of air gap flux density of the new secondary structure TPMLWG are improved, the cogging force as well as mechanical vibration is reduced in the process of operation, and the stable temperature rise of generator meets the design requirements when adopting the new secondary structure of the TPMLWG.

  14. Design and Analysis of Tubular Permanent Magnet Linear Wave Generator

    Science.gov (United States)

    Si, Jikai; Feng, Haichao; Su, Peng; Zhang, Lufeng

    2014-01-01

    Due to the lack of mature design program for the tubular permanent magnet linear wave generator (TPMLWG) and poor sinusoidal characteristics of the air gap flux density for the traditional surface-mounted TPMLWG, a design method and a new secondary structure of TPMLWG are proposed. An equivalent mathematical model of TPMLWG is established to adopt the transformation relationship between the linear velocity of permanent magnet rotary generator and the operating speed of TPMLWG, to determine the structure parameters of the TPMLWG. The new secondary structure of the TPMLWG contains surface-mounted permanent magnets and the interior permanent magnets, which form a series-parallel hybrid magnetic circuit, and their reasonable structure parameters are designed to get the optimum pole-arc coefficient. The electromagnetic field and temperature field of TPMLWG are analyzed using finite element method. It can be included that the sinusoidal characteristics of air gap flux density of the new secondary structure TPMLWG are improved, the cogging force as well as mechanical vibration is reduced in the process of operation, and the stable temperature rise of generator meets the design requirements when adopting the new secondary structure of the TPMLWG. PMID:25050388

  15. Rational design of the exchange-spring permanent magnet.

    Science.gov (United States)

    Jiang, J S; Bader, S D

    2014-02-12

    The development of the optimal exchange-spring permanent magnet balances exchange hardening, magnetization enhancement, and the feasibility of scalable fabrication. These requirements can be met with a rational design of the microstructural characteristics. The magnetization processes in several model exchange-spring structures with different geometries have been analyzed with both micromagnetic simulations and nucleation theory. The multilayer geometry and the soft-cylinders-in-hard-matrix geometry have the highest achievable figure of merit (BH)max, while the soft-spheres-in-hard-matrix geometry has the lowest upper limit for (BH)max. The cylindrical geometry permits the soft phase to be larger and does not require strict size control. Exchange-spring permanent magnets based on the cylindrical geometry may be amenable to scaled-up fabrication.

  16. Rational design of the exchange-spring permanent magnet

    International Nuclear Information System (INIS)

    Jiang, J S; Bader, S D

    2014-01-01

    The development of the optimal exchange-spring permanent magnet balances exchange hardening, magnetization enhancement, and the feasibility of scalable fabrication. These requirements can be met with a rational design of the microstructural characteristics. The magnetization processes in several model exchange-spring structures with different geometries have been analyzed with both micromagnetic simulations and nucleation theory. The multilayer geometry and the soft-cylinders-in-hard-matrix geometry have the highest achievable figure of merit (BH) max , while the soft-spheres-in-hard-matrix geometry has the lowest upper limit for (BH) max . The cylindrical geometry permits the soft phase to be larger and does not require strict size control. Exchange-spring permanent magnets based on the cylindrical geometry may be amenable to scaled-up fabrication. (paper)

  17. Combined percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation for rheumatic mitral stenosis and atrial fibrillation

    International Nuclear Information System (INIS)

    Murdoch, Dale; McAulay, Laura; Walters, Darren L.

    2014-01-01

    Rheumatic heart disease is a common cause of cardiovascular morbidity and mortality worldwide, mostly in developing countries. Mitral stenosis and atrial fibrillation often coexist, related to both structural and inflammatory changes of the mitral valve and left atrium. Both predispose to left atrial thrombus formation, commonly involving the left atrial appendage. Thromboembolism can occur, with devastating consequences. We report the case of a 62 year old woman with rheumatic heart disease resulting in mitral stenosis and atrial fibrillation. Previous treatment with warfarin resulted in life-threatening gastrointestinal bleeding and she refused further anticoagulant therapy. A combined procedure was performed, including percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation with the Atritech® Watchman® device. No thromboembolic or bleeding complications were encountered at one year follow-up. Long-term follow-up in a cohort of patients will be required to evaluate the safety and efficacy of this strategy

  18. Combined percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation for rheumatic mitral stenosis and atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Murdoch, Dale, E-mail: dale_murdoch@health.qld.gov.au [The Prince Charles Hospital, Brisbane (Australia); The University of Queensland, Brisbane (Australia); McAulay, Laura [The Prince Charles Hospital, Brisbane (Australia); Walters, Darren L. [The Prince Charles Hospital, Brisbane (Australia); The University of Queensland, Brisbane (Australia)

    2014-11-15

    Rheumatic heart disease is a common cause of cardiovascular morbidity and mortality worldwide, mostly in developing countries. Mitral stenosis and atrial fibrillation often coexist, related to both structural and inflammatory changes of the mitral valve and left atrium. Both predispose to left atrial thrombus formation, commonly involving the left atrial appendage. Thromboembolism can occur, with devastating consequences. We report the case of a 62 year old woman with rheumatic heart disease resulting in mitral stenosis and atrial fibrillation. Previous treatment with warfarin resulted in life-threatening gastrointestinal bleeding and she refused further anticoagulant therapy. A combined procedure was performed, including percutaneous balloon mitral valvuloplasty and left atrial appendage occlusion device implantation with the Atritech® Watchman® device. No thromboembolic or bleeding complications were encountered at one year follow-up. Long-term follow-up in a cohort of patients will be required to evaluate the safety and efficacy of this strategy.

  19. Analysis of the pathological severity degree of aortic stenosis (AS) and mitral stenosis (MS) using the discrete wavelet transform (DWT).

    Science.gov (United States)

    Meziani, F; Debbal, S M; Atbi, A

    2013-01-01

    The heart is the principal organ that circulates blood. In normal conditions it produces four sounds for each cardiac cycle. However, most often only two sounds appear essential: S1 and S2. Two other sounds: S3 and S4, with lower amplitude than S1 or S2, appear occasionally in the cardiac cycle by the effect of disease or age. The presence of abnormal sounds in one cardiac cycle provide valuable information on various diseases. The aortic stenosis (AS), as being a valvular pathology, is characterized by a systolic murmur due to a narrowing of the aortic valve. The mitral stenosis (MS) is characterized by a diastolic murmur due to a reduction in the mitral valve. Early screening of these diseases is necessary; it's done by a simple technique known as: phonocardiography. Analysis of phonocardiograms signals using signal processing techniques can provide for clinicians useful information considered as a platform for significant decisions in their medical diagnosis. In this work two types of diseases were studied: aortic stenosis (AS) and mitral stenosis (MS). Each one presents six different cases. The application of the discrete wavelet transform (DWT) to analyse pathological severity of the (AS and MS was presented. Then, the calculation of various parameters was performed for each patient. This study examines the possibility of using the DWT in the analysis of pathological severity of AS and MS.

  20. Impact of hypertension on left ventricular structure in patients with asymptomatic aortic valve stenosis (a SEAS substudy)

    DEFF Research Database (Denmark)

    Rieck, Ashild E; Cramariuc, Dana; Staal, Eva M

    2010-01-01

    Both hypertension and aortic valve stenosis induce left ventricular hypertrophy. However, less is known about the influence of concomitant hypertension on left ventricular structure in patients with aortic valve stenosis.......Both hypertension and aortic valve stenosis induce left ventricular hypertrophy. However, less is known about the influence of concomitant hypertension on left ventricular structure in patients with aortic valve stenosis....

  1. Simulation of dynamics of a permanent magnet linear actuator

    DEFF Research Database (Denmark)

    Yatchev, Ivan; Ritchie, Ewen

    2010-01-01

    Comparison of two approaches for the simulation of the dynamic behaviour of a permanent magnet linear actuator is presented. These are full coupled model, where the electromagnetic field, electric circuit and mechanical motion problems are solved simultaneously, and decoupled model, where first...... flexibility when the actuator response is required to be estimated for different external conditions, e.g. external circuit parameters or mechanical loads....

  2. Clinical profile and management options of children with congenital esophageal stenosis: A single center experience

    Directory of Open Access Journals (Sweden)

    Jujju Jacob Kurian

    2016-01-01

    Full Text Available Aim: The aim of the study is to review 7 patients with congenital esophageal stenosis treated in our institution from a diagnostic and therapeutic point of view. Materials and Methods: This is a retrospective cohort study of 7 patients treated in Christian Medical College, Vellore from 2008 to 2014. The data were analyzed with regards to age at onset of symptoms, investigative findings, age at definitive treatment, pathology, modalities of treatment, and outcomes. Results: Symptoms started within the 1 st year of life in all children with a median age of 4 months. The time of delay in diagnosis ranged from 8 months to 81 months with a mean period of 37 months. About 6 patients had a lower esophageal stenosis and 1 patient had a mid-esophageal stenosis. About 4 of the 7 children underwent endoscopic balloon dilatation from elsewhere, with 2 of the above 4 undergoing a myotomy for a wrongly diagnosed achalasia. The number of dilatations ranged from 2 to 7 with a mean of 4 dilatations. Resection of the stenotic segment with end to end anastomosis was employed in 6 of the 7 patients, and a transverse colon interpositioning was done in 1 patient. An antireflux procedure was performed in one patient. Histopathological examination of the resected specimen revealed tracheobronchial remnant in 3 patients, fibromuscular thickening in 3 patients, and membranous web in 1 patient. Postoperatively, 2 of the 7 patients had asymptomatic gastroesophageal reflux and 1 patient had postoperative stricture requiring one session of endoscopic balloon dilatation. The mean follow-up period was 42 months (range 18-72 months. At the time of the last follow-up, all 7 patients were able to eat solid food, and none of the children were found to have symptoms suggestive of obstruction or gastroesophageal reflux. There was a statistically significant increase in the weight for age after the operation. Conclusion: Congenital esophageal stenosis is rare and often confused with

  3. MR-Guided PTA in Experimental Bilateral Rabbit Renal Artery Stenosis and MR Angiography Follow-Up Versus Histomorphometry

    International Nuclear Information System (INIS)

    Le Blanche, Alain-Ferdinand; Rossert, Jerome; Wassef, Michel; Levy, Bernard; Bigot, Jean-Michel; Boudghene, Frank

    2000-01-01

    Purpose: To assess in vivo 1) MR-guided percutaneous transluminal renal angioplasty (PTRA) in experimental bilateral rabbit renal artery stenosis (RAS); 2) postprocedural follow-up by gadolinium-enhanced MR angiography versus histomorphometry.Methods: Fifteen male NZW rabbits of mean weight 4.0 kg (range 3.5-4.2 kg) underwent bilateral RAS induction by combined overdilation-deendothelialization with a gadolinium-filled balloon, passively MR-guided by the artifact of a 0.014-inch guidewire. After 4 weeks the rabbits were randomized into two groups: group A (n = 8) underwent right-sided PTRA for treatment of RAS, group B (n = 7) underwent left-sided PTRA. After another 4 weeks the rabbits were killed to assess by histomorphometry recurrent stenosis and contralateral induction injury stenosis lesions. Each step was preceded by gadolinium-enhanced three-dimensional MR angiography, and the cortex-to-aorta (C/A) signal intensity ratio was calculated.Results: RAS induction was successful in all cases. Fourteen arteries developed restenosis and 13 only initial stenosis. MR-guided PTRAs were feasible in 22 arteries (73%). For a successful catheterization of the ostium (20 arteries, 66% success rate), 10-25 steps were required. Five to eight steps were required for balloon localization and inflation for each PTRA. The restenosis effect was reflected by a 16% (12%-27%) decrease in C/A values on MR angiograms (p < 0.05).Conclusion: MR guidance and MR angiography represent a feasible, less invasive alternative for performing and assessing experimental PTRA in RAS

  4. Economic impact of an ultrasonographic contrast agent on the diagnosis and initial management of patients with suspected renal artery stenosis

    International Nuclear Information System (INIS)

    Levesque, J.; Lacourciere, Y.; Onrot, J.M.

    2002-01-01

    To determine resource use in the diagnosis and management of Canadian hypertensive patients with suspected renal artery stenosis and to estimate the impact of diagnosis with contrast-enhanced duplex Doppler ultrasonography (US) on resource use. Seventy-eight patients with suspected renal artery stenosis underwent usual diagnostic tests (captopril-enhanced renal scintigraphy or duplex Doppler US) and contrast-enhanced US. A management pathway ('planned') describing the medical resources required for further patient care was outlined on the basis of results from each test (separately), and a modified management pathway ('recommended'), which considered data from both diagnostic methods, was also outlined. Medical resources and productivity losses were assessed prospectively for a 3-month period after patients underwent both tests ('actual' management pathway). With usual diagnostic methods, 14 (18%) of the tests were inconclusive, whereas only 1 (1%) of the enhanced US examinations was inconclusive; the cost-efficacy ratio was $422 and $343 per successful diagnosis, respectively. Further management costs for patients with an inconclusive diagnosis were estimated at $6370 after the usual diagnostic tests, but only $1278 with enhanced US. Although the costs of the planned and recommended management pathways were similar ($227 and $294 per patient respectively), the proportion of patients requiring further resources was lower with enhanced US (56% v. 46%). Three-month actual management costs ranged from $121 to $1605 per patient (mean $360). Diagnostic tests and surgical procedures were the major cost drivers in all pathways, and costs wore highest for patients in whom stenosis was diagnosed. For patients with suspected renal artery stenosis, contrast-enhanced US had a higher diagnostic success rate than usual diagnostic methods and afforded savings through lower administrative costs and lower medical resource consumption for patients whose diagnosis was unclear after

  5. Artefacts at a glance: differentiating features of artefactual stenosis from true stenosis at the genu of the petrous internal carotid artery on TOF MRA

    International Nuclear Information System (INIS)

    Lee, S.K.; Ahn, K.J.; Jang, J.H.; Choi, H.S.; Jung, S.L.; Kim, B.S.

    2016-01-01

    Aim: To investigate the distinguishing features of artefactual stenosis from true stenosis at the genu of the petrous internal carotid artery (ICA) on time of flight (TOF) magnetic resonance angiography (MRA). Materials and methods: Both TOF MRA and digital subtraction angiography (DSA) were performed in 65 patients with 74 vessels who demonstrated artefactual stenosis in 43 patients with 50 vessels and true stenosis in 22 patients with 24 vessels. The following findings of the signal loss were compared between the two groups: (1) margin, (2) darkness, (3) the presence of bilaterality, (4) the presence of tandem arterial stenosis, (5) the location of the epicentre, and (6) length. Results: In five out of the six evaluated items, statistically significant differences were present between the two groups (p<0.00 in all five items). Artefactual stenosis more frequently showed signal loss with ill-defined margins (47/50), less darkness compared to the background darkness (46/50), the absence of tandem arterial stenosis (35/50), epicentre at the genu (34/50), and shorter length (2.57 ± 0.68 mm). No significant difference was noted in the presence of bilaterality of signal loss between the two groups (p=0.706). Conclusion: Several MRA features can be useful for suggesting artefactual stenosis rather than true stenosis at the genu of the petrous ICA on TOF MRA. - Highlights: • TOF MRA is increasingly used for the noninvasive evaluation for imaging the cerebrovascular system. • We investigated several artifacts at the genu of petrous ICA on TOF MRA to prevent misinterpretations as true stenosis. • Short segmental, ill-defined, less dark defect at the epicenter of genu without tandem stenosis is more likely an artifact.

  6. Rare earth elements and permanent magnets (invited)

    Science.gov (United States)

    Dent, Peter C.

    2012-04-01

    Rare earth (RE) magnets have become virtually indispensible in a wide variety of industries such as aerospace, automotive, electronics, medical, and military. RE elements are essential ingredients in these high performance magnets based on intermetallic compounds RECo5, RE2TM17 (TM: transition metal), and RE2TM14B. Rare earth magnets are known for their superior magnetic properties—high induction, and coercive force. These properties arise due to the extremely high magnetocrystalline anisotropy made possible by unique 3d-4f interactions between transition metals and rare earths. For more than 40 years, these magnets remain the number one choice in applications that require high magnetic fields in extreme operating conditions—high demagnetization forces and high temperature. EEC produces and specializes in RECo5 and RE2TM17 type sintered magnets. Samarium and gadolinium are key RE ingredients in the powder metallurgical magnet production processes which include melting, crushing, jet milling, pressing, sintering, and heat treating. The magnetic properties and applications of these magnets will be discussed. We will also briefly discuss the past, current, and future of the permanent magnet business. Currently, over 95% of all pure rare earth oxides are sourced from China, which currently controls the market. We will provide insights regarding current and potential new magnet technologies and designer choices, which may mitigate rare earth supply chain issues now and into the future.

  7. Aortic annulus and ascending aorta: Comparison of preoperative and periooperative measurement in patients with aortic stenosis

    International Nuclear Information System (INIS)

    Smid, Michal; Ferda, Jiri; Baxa, Jan; Cech, Jakub; Hajek, Tomas; Kreuzberg, Boris; Rokyta, Richard

    2010-01-01

    Background: Precise determination of the aortic annulus size constitutes an integral part of the preoperative evaluation prior to aortic valve replacement. It enables the estimation of the size of prosthesis to be implanted. Knowledge of the size of the ascending aorta is required in the preoperative analysis and monitoring of its dilation enables the precise timing of the operation. Our goal was to compare the precision of measurement of the aortic annulus and ascending aorta using magnetic resonance (MR), multidetector-row computed tomography (MDCT), transthoracic echocardiography (TTE), and transoesophageal echocardiography (TEE) in patients with degenerative aortic stenosis. Methods and results: A total of 15 patients scheduled to have aortic valve replacement were enrolled into this prospective study. TTE was performed in all patients and was supplemented with TEE, CT and MR in the majority of patients. The values obtained were compared with perioperative measurements. For the measurement of aortic annulus, MR was found to be the most precise technique, followed by MDCT, TTE, and TEE. For the measurement of ascending aorta, MR again was found to be the most precise technique, followed by MDCT, TEE, and TTE. Conclusion: In our study, magnetic resonance was found to be the most precise technique for the measurement of aortic annulus and ascending aorta in patients with severe degenerative aortic stenosis.

  8. Not Always Asthma: Clinical and Legal Consequences of Delayed Diagnosis of Laryngotracheal Stenosis

    Directory of Open Access Journals (Sweden)

    Adam C. Nunn

    2014-01-01

    Full Text Available Laryngotracheal stenosis (LTS is a rare condition that occurs most commonly as a result of instrumentation of the airway but may also occur as a result of inflammatory conditions or idiopathically. Here, we present the case of a patient who developed LTS as a complication of granulomatosis with polyangiitis (GPA, which was misdiagnosed as asthma for 6 years. After an admission with respiratory symptoms that worsened to the extent that she required intubation, a previously well 14-year-old girl was diagnosed with GPA. Following immunosuppressive therapy, she made a good recovery and was discharged after 22 days. Over subsequent years, she developed dyspnoea and “wheeze” and a diagnosis of asthma was made. When she became pregnant, she was admitted to hospital with worsening respiratory symptoms, whereupon her “wheeze” was correctly identified as “stridor,” and subsequent investigations revealed a significant subglottic stenosis. The delay in diagnosis precluded the use of minimally invasive therapies, with the result that intermittent laser resection and open laryngotracheal reconstructive surgery were the only available treatment options. There were numerous points at which the correct diagnosis might have been made, either by proper interpretation of flow-volume loops or by calculation of the Empey or Expiratory Disproportion Indices from spirometry data.

  9. Cephalic Arch Stenosis in Autogenous Haemodialysis Fistulas: Treatment With the Viabahn Stent-Graft

    Energy Technology Data Exchange (ETDEWEB)

    Shawyer, Andrew, E-mail: andrew.shawyer@bartsandthelondon.nhs.uk [The Royal London Hospital, Radiology Department (United Kingdom); Fotiadis, Nicos I., E-mail: fotiadis.nicholas@gmail.com [Royal Marsden Hospital, Radiology Department, The Royal Marsden NHS Foundation Trust (United Kingdom); Namagondlu, Girish, E-mail: girish.namagondlu@bartsandthelondon.nhs.uk [The Royal London Hospital, Renal Medicine Department (United Kingdom); Iyer, Arun, E-mail: arun.iyer@bartsandthelondon.nhs.uk [The Royal London Hospital, Radiology Department (United Kingdom); Blunden, Mark, E-mail: mark.blunden@bartsandthelondon.nhs.uk; Raftery, Martin, E-mail: martin.raftery@bartsandthelondon.nhs.uk; Yaqoob, Magdi, E-mail: magdi.yaqoob@bartsandthelondon.nhs.uk [The Royal London Hospital, Renal Medicine Department (United Kingdom)

    2013-02-15

    Cephalic arch stenosis (CAS) is an important and common cause of dysfunction in autogenous haemodialysis fistulas that requires multiple reinterventions and aggressive surveillance. We evaluated the safety and efficacy of the Viabahn stent-graft for the management of CAS. Between April 2005 and October 2011, 11 consecutive patients [four men and seven women (mean age 56.7 years)] with CAS and dysfunctional fistulas were treated with insertion of 11 Viabahn stent-grafts. Six stent-grafts were inserted due to residual stenosis after angioplasty and five for fistuloplasty-induced rupture. No patient was lost to follow-up. The technical and clinical success rate was 100 %. Primary access patency rates were 81.8 % [95 % confidence interval (CI) 0.482-0.977] at 6 months and 72.7 % (95 % CI 0.390-0.939) at 12 months. Secondary access patency rates were 90.9 % at 6 months (95 % CI 0.587-0.997). There were no procedure-related complications. Mean follow-up was 543.8 days (range 156-2,282). The use of the Viabahn stent-graft in the management of CAS is technically feasible and, in this small series, showed patency rates that compare favorably with historical data of angioplasty and bare stents.

  10. Cephalic Arch Stenosis in Autogenous Haemodialysis Fistulas: Treatment With the Viabahn Stent-Graft

    International Nuclear Information System (INIS)

    Shawyer, Andrew; Fotiadis, Nicos I.; Namagondlu, Girish; Iyer, Arun; Blunden, Mark; Raftery, Martin; Yaqoob, Magdi

    2013-01-01

    Cephalic arch stenosis (CAS) is an important and common cause of dysfunction in autogenous haemodialysis fistulas that requires multiple reinterventions and aggressive surveillance. We evaluated the safety and efficacy of the Viabahn stent-graft for the management of CAS. Between April 2005 and October 2011, 11 consecutive patients [four men and seven women (mean age 56.7 years)] with CAS and dysfunctional fistulas were treated with insertion of 11 Viabahn stent-grafts. Six stent-grafts were inserted due to residual stenosis after angioplasty and five for fistuloplasty-induced rupture. No patient was lost to follow-up. The technical and clinical success rate was 100 %. Primary access patency rates were 81.8 % [95 % confidence interval (CI) 0.482–0.977] at 6 months and 72.7 % (95 % CI 0.390–0.939) at 12 months. Secondary access patency rates were 90.9 % at 6 months (95 % CI 0.587–0.997). There were no procedure-related complications. Mean follow-up was 543.8 days (range 156–2,282). The use of the Viabahn stent-graft in the management of CAS is technically feasible and, in this small series, showed patency rates that compare favorably with historical data of angioplasty and bare stents.

  11. Renal artery stenosis: comparative assessment by unenhanced renal artery mra versus contrast-enhanced MRA

    International Nuclear Information System (INIS)

    Khoo, Michael M.Y.; Deeab, Dhafer; Gedroyc, Wladyslaw M.W.; Dick, Elizabeth A.; Duncan, Neil; Taube, David

    2011-01-01

    To evaluate steady-state free precession (SSFP) non-contrast-enhanced MR angiography (Unenhanced-MRA) versus conventional contrast-enhanced MR angiography (CE-MRA) in the detection of renal artery stenosis (RAS). Retrospective analysis of 70 consecutive patients referred for suspected RAS, examined by SSFP Unenhanced-MRA and CE-MRA. Image quality, quality of visible renal arterial segments, presence and grade of RAS were evaluated. The Unenhanced-MRA were compared against reference standard CE-MRA results. 149 renal arteries were assessed with 21 haemodynamically significant stenoses (≥50% stenosis) demonstrated by CE-MRA. Combined sensitivity and specificity for RAS detection by Unenhanced-MRA was 72.8% and 97.8% respectively. There is substantial correlation for RAS detection between Unenhanced-MRA and CE-MRA with kappa values of between 0.64 and 0.74. There was excellent inter-observer correlation for RAS on Unenhanced-MRA (kappa values 0.82-1.0). Our study has shown Unenhanced-MRA to be a viable alternative to CE-MRA, yielding images equal in quality without the requirement for gadolinium contrast agents. The sensitivity and specificity for the detection of haemodynamically significant stenoses are comparable to CE-MRA. Potentially, Unenhanced-MRA could be used as an initial investigation to avoid performing CE-MRA in patients with normal renal arteries, however we suggest that its real value will lie in being complementary to CE-MRA. (orig.)

  12. Permanent multipole magnets with adjustable strength

    International Nuclear Information System (INIS)

    Halbach, K.

    1983-01-01

    Preceded by a short discussion of the motives for using permanent magnets in accelerators, a new type of permanent magnet for use in accelerators is presented. The basic design and most important properties of a quadrople will be described that uses both steel and permanent magnet material. The field gradient produced by this magnet can be adjusted without changing any other aspect of the field produced by this quadrupole. The generalization of this concept to produce other multipole fields, or combination of multipole fields, will also be presented

  13. Nanocrystalline permanent magnets with enhanced properties

    International Nuclear Information System (INIS)

    Leonowicz, M.

    2002-01-01

    Parameters of permanent magnets result from the combination of intrinsic properties such as saturation magnetization, magnetic exchange, and magnetocrystalline energy, as well as microstructural parameters such as phase structure, grain size, and orientation. Reduction of grain size into nanocrystalline regime (∼ 50 nm) leads to the enhanced remanence which derives from ferromagnetic exchange coupling between highly refined grains. In this study the fundamental phenomena, quantities, and structure parameters, which define nanophase permanent magnets are presented and discussed. The theoretical considerations are confronted with experimental data for nanocrystalline Sm-Fe-N type permanent magnets. (author)

  14. Permanent molars: Delayed development and eruption

    Directory of Open Access Journals (Sweden)

    Arathi R

    2006-05-01

    Full Text Available Delayed development and eruption of all the permanent molars is a rare phenomenon, which can cause disturbance in the developing occlusion. The eruption of permanent first and second molars is very important for the coordination of facial growth and for providing sufficient occlusal support for undisturbed mastication. In the case described, the first permanent molars were delayed in their development and were seen erupting at the age of nine and a half years. Severe disparity between the left and the right side of the dentition with respect to the rate of development of molars were also present.

  15. Permanent multipole magnets with adjustable strength

    International Nuclear Information System (INIS)

    Halbach, K.

    1983-03-01

    Preceded by a short discussion of the motives for using permanent magnets in accelerators, a new type of permanent magnet for use in accelerators is presented. The basic design and most important properties of a quadrupole will be described that uses both steel and permanent magnet material. The field gradient produced by this magnet can be adjusted without changing any other aspect of the field produced by this quadrupole. The generalization of this concept to produce other multipole fields, or combination of multipole fields, will also be presented

  16. Radioecological sensitivity of permanent grasslands

    International Nuclear Information System (INIS)

    Besson, Benoit

    2009-01-01

    The project 'SENSIB' of the Institute for Radiological Protection and Nuclear Safety (IRSN) aims at characterizing and classifying parameters with significant impact on the transfer of radioactive contaminants in the environment. This thesis is focused on permanent grassland areas. Its objectives are the analysis of the activity variations of two artificial radionuclides ( 137 Cs and 90 Sr) in the chain from soil to dairy products as well as the categorization of ecological and anthropogenic parameters, which determine the sensitivity of the studied area. For this study, in situ sampling is carried out in 15 farms in 3 different French regions (Charente, Puy-de-Dome and Jura). The sampling sites are chosen according to their natural variations (geology, altitude and climate) and the soil types. Additionally to the radiologic measurements, geographic, soil and vegetation data as well as data concerning cattle-rearing and cheese manufacturing processes are gathered. From the soil to the grass vegetation, 137 Cs transfer factors vary between 3 x 10-3 and 148 x 10-3 Bq kg-1 (dry weight) per Bq kg-1 (dry weight) (N = 73). Theses transfer factors are significantly higher in the Puy-de-Dome region than in the Jura region. The 137 Cs transfer factor from cattle feed to milk varies from 5.9 x 10-3 to 258 x 10-3 Bq kg-1 (fresh weight) per Bq kg-1 (dry weight) (N = 28). Statistically, it is higher in the Charente region. Finally, the 90 Sr transfer factor from milk to cheese ranges from 3.9 to 12.1. The studied site with the highest factor is the Jura (N = 25). The link between milk and dairy products is the stage with the most 137 Cs and 90 Sr transfers. A nonlinear approach based on a discretization method of the transfer factor with multiple comparison tests admits a classification of the sensitivity factors from soil to grass vegetation. We can determine 20 factors interfering in the 137 Cs transfer into the vegetation, for instance, the clay rate of the soils or a marker

  17. Quality of life after permanent prostate implant

    International Nuclear Information System (INIS)

    Arterbery, V. Elayne; Frazier, Arthur; Dalmia, Praveen; Porter, Arthur

    1997-01-01

    Purpose: To report on the quality of life in patients who have received a permanent transperineal ultrasound guide prostate implant. There is increasing recognition that prostate cancer therapy impacts significantly on the patients ability to pursue relational, occupational and social interests. With the substantially expanded patient role in directing treatment for prostate cancer, the importance of examining quality of life outcomes in addition to survival has been underscored. Materials and Methods: 51 sequential patients with clinically localized prostate cancer who underwent permanent prostate implantation from September 1995 to October 1996 were evaluated. All patients were clinically staged as T1c or T2a and received implant with Iodine 125 or Palladium 103 as definitive treatment. Data was collected using the EORTC genitourinary group questionnaire and supplemental questions during an interview. Results: Urinary symptoms such as nocturia, frequency and dysuria were the most pronounced in the first two months after implant and then decreased in the majority of patients. The EORTC questionnaire was administered at 6 months and examined urinary quality, sexual quality and perception of symptoms. With regard to urinary quality, 17% had mild dysuria at 6 months and 40% noted that they urinated more frequently than pre implant. No patient had hematuria and 0 % were incontinent. 3% stated that they had occasional loss of minimal urine with severe urgency. Only 2% required intermittent self catheterization after implant secondary to obstructive symptoms. Over 90% were on an alpha blocker post implant for a minimum of 6 weeks. 0% reported psychological distress and 3% noted a disruption in social or family life. 15% experienced some fatigue and 10% noted a decreased functional status but only 1% a decreased role function. Additional questions addressed lifestyle and work issues. 100% would have an implant again as definitive treatment and 98% would recommend the

  18. Primary Stenting Is Not Necessary in Benign Central Venous Stenosis.

    Science.gov (United States)

    Rangel, Lynsey E; Lyden, Sean P; Clair, Daniel G

    2018-01-01

    The aim of this study is to evaluate central venous stenosis (CVS) etiologies and presentation within a vascular surgery practice. We evaluated endovascular treatment modalities and the patency rates of our interventions. Five-year retrospective review of endovascular intervention for CVS. Patient demographics, medical comorbidities, and variables were collected including etiology, indwelling device, previous upper extremity (UE) deep venous thrombosis, long-term UE indwelling device (defined as >30 days), malignancy status, hypercoagulable disorders, history of radiation or mediastinal fibrosis or masses, and anticoagulation and/or antiplatelet therapy. Follow-up variables included symptoms, imaging, and anticoagulation and/or antiplatelet utilization. Living patients without recent follow-up were contacted with a telephone survey regarding current symptoms. Patency was evaluated by imaging or clinically by recurrence of signs or symptoms through January 2016. A total of 61 patients underwent attempted endovascular CVS interventions from January 2007 to 2013. Forty-seven (83%) patients had successful interventions. There were 22 (36%) end-stage renal disease (ESRD) patients. The primary etiology in 79% of patients was benign CVS secondary to an indwelling device. Eighty-nine percent of the interventions were primary angioplasty (PTA). The overall primary patency rates at 6, 12, and 24 months were 49%, 34%, and 24%, respectively. Secondary patency rates at 6, 12, and 24 months were 97%, 93%, and 88%, respectively. There were no statistical differences in demographics or outcomes in patients treated successfully with PTA or those requiring stenting. There was no statistical difference in the patency rates between ESRD and non-ESRD patients. Previous interventions were not a predictor of loss of patency. Our study supported the rising trend of benign CVS predominantly secondary to indwelling devices. We demonstrated acceptable secondary patency with PTA alone

  19. Carotid stenosis measurement on colour Doppler ultrasound: Agreement of ECST, NASCET and CCA methods applied to ultrasound with intra-arterial angiographic stenosis measurement

    International Nuclear Information System (INIS)

    Wardlaw, Joanna M.; Lewis, Steff

    2005-01-01

    Purpose: Carotid stenosis is usually determined on Doppler ultrasound from velocity readings. We wondered if angiography-style stenosis measurements applied to ultrasound images improved accuracy over velocity readings alone, and if so, which measure correlated best with angiography. Materials and methods: We studied prospectively patients undergoing colour Doppler ultrasound (CDU) for TIA or minor stroke. Those with 50%+ symptomatic internal carotid artery (ICA) stenosis had intra-arterial angiography (IAA). We measured peak systolic ICA velocity, and from the ultrasound image, the minimal residual lumen, the original lumen (ECST), ICA diameter distal (NASCET) and CCA diameter proximal (CCA method) to the stenosis. The IAAs were measured by ECST, NASCET and CCA methods also, blind to CDU. Results: Amongst 164 patients (328 arteries), on CDU the ECST, NASCET and CCA stenosis measures were similarly related to each other (ECST = 0.54 NASCET + 46) as on IAA (ECST = 0.6 NASCET + 40). Agreement between CDU- and IAA-measured stenosis was similar for ECST (r = 0.51), and CCA (r = 0.48) methods, and slightly worse for NASCET (r = 0.41). Adding IAA-style stenosis to the peak systolic ICA velocity did not improve agreement with IAA over peak systolic velocity alone. Conclusion: Angiography-style stenosis measures have similar inter-relationships when applied to CDU, but do not improve accuracy of ultrasound over peak systolic ICA velocity alone

  20. When stenting in renal artery stenosis? Update on pathophysiology of ischemic nephropathy and management strategies

    Directory of Open Access Journals (Sweden)

    Alessandro Zuccalà

    2013-11-01

    Full Text Available In recent years, decisions taken on the optimal management of patients with renal artery stenosis have triggered off controversy and debate among clinicians dealing with renovascular disease. The main reason underlying this ongoing controversy may be the heterogeneity of the clinical entities that are normally associated with the umbrella definition of renal artery stenosis. Indeed a causal link between the stenosis and its clinical consequences (i.e. hypertension, renal failure can often demonstrated in some entities, such as fibromuscular dysplasia, truncal stenosis or arterial stenosis in the transplanted kidney, which can be defined as pure renal artery stenosis. On the contrary, the entity generally called ostial stenosis is a disease of the abdominal aorta where it encroaches the ostium of the renal artery at the end of a long process involving the entire vascular tree. Patients affected by ostial stenosis also suffer from generalized atherosclerosis, and kidney damage is often caused by the atherosclerotic environment with the stenosis acting as an innocent bystander. This may account for the low rate of renal function recovery in subjects with ostial stenosis. In our view, keeping the different entities separate along with a careful understanding of the mechanisms underpinning renal damage, particularly the intrarenal activation of the renin angiotensin system which in turn induces renal inflammation and oxidative stress, may enable clinicians to make the right decisions in regard to revascularization.

  1. Nonuniform radiation damage in permanent magnet quadrupoles.

    Science.gov (United States)

    Danly, C R; Merrill, F E; Barlow, D; Mariam, F G

    2014-08-01

    We present data that indicate nonuniform magnetization loss due to radiation damage in neodymium-iron-boron Halbach-style permanent magnet quadrupoles. The proton radiography (pRad) facility at Los Alamos uses permanent-magnet quadrupoles for magnifying lenses, and a system recently commissioned at GSI-Darmsdadt uses permanent magnets for its primary lenses. Large fluences of spallation neutrons can be produced in close proximity to these magnets when the proton beam is, intentionally or unintentionally, directed into the tungsten beam collimators; imaging experiments at LANL's pRad have shown image degradation with these magnetic lenses at proton beam doses lower than those expected to cause damage through radiation-induced reduction of the quadrupole strength alone. We have observed preferential degradation in portions of the permanent magnet quadrupole where the field intensity is highest, resulting in increased high-order multipole components.

  2. Nonuniform radiation damage in permanent magnet quadrupoles

    International Nuclear Information System (INIS)

    Danly, C. R.; Merrill, F. E.; Barlow, D.; Mariam, F. G.

    2014-01-01

    We present data that indicate nonuniform magnetization loss due to radiation damage in neodymium-iron-boron Halbach-style permanent magnet quadrupoles. The proton radiography (pRad) facility at Los Alamos uses permanent-magnet quadrupoles for magnifying lenses, and a system recently commissioned at GSI-Darmsdadt uses permanent magnets for its primary lenses. Large fluences of spallation neutrons can be produced in close proximity to these magnets when the proton beam is, intentionally or unintentionally, directed into the tungsten beam collimators; imaging experiments at LANL’s pRad have shown image degradation with these magnetic lenses at proton beam doses lower than those expected to cause damage through radiation-induced reduction of the quadrupole strength alone. We have observed preferential degradation in portions of the permanent magnet quadrupole where the field intensity is highest, resulting in increased high-order multipole components

  3. Nonuniform radiation damage in permanent magnet quadrupoles

    Energy Technology Data Exchange (ETDEWEB)

    Danly, C. R.; Merrill, F. E.; Barlow, D.; Mariam, F. G. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States)

    2014-08-15

    We present data that indicate nonuniform magnetization loss due to radiation damage in neodymium-iron-boron Halbach-style permanent magnet quadrupoles. The proton radiography (pRad) facility at Los Alamos uses permanent-magnet quadrupoles for magnifying lenses, and a system recently commissioned at GSI-Darmsdadt uses permanent magnets for its primary lenses. Large fluences of spallation neutrons can be produced in close proximity to these magnets when the proton beam is, intentionally or unintentionally, directed into the tungsten beam collimators; imaging experiments at LANL’s pRad have shown image degradation with these magnetic lenses at proton beam doses lower than those expected to cause damage through radiation-induced reduction of the quadrupole strength alone. We have observed preferential degradation in portions of the permanent magnet quadrupole where the field intensity is highest, resulting in increased high-order multipole components.

  4. Genetics Home Reference: permanent neonatal diabetes mellitus

    Science.gov (United States)

    ... AL. Update on mutations in glucokinase (GCK), which cause maturity-onset diabetes of the young, permanent neonatal diabetes, and hyperinsulinemic hypoglycemia. Hum Mutat. 2009 Nov;30(11):1512-26. ...

  5. Canadian Eskimo permanent tooth emergence timing.

    Science.gov (United States)

    Mayhall, J T; Belier, P L; Mayhall, M F

    1978-08-01

    To identify the times of emergence of the permanent teeth of Canadian Eskimos (Inuit), 368 children and adolescents were examined. The presence or absence of all permanent teeth except the third molars was recorded and these data subjected to probit analysis. Female emergence times were advanced over males. Generally, the Inuit of both sexes showed statistically significant earlier emergence times than Montreal children, except for the incisors. The present results do not support hypotheses indicating that premature extraction of the deciduous teeth advances the emergence of their succedaneous counterparts. There is some indication the controls of deciduous tooth emergence continue to play some part in emergence of the permanent dentition, especially the first permanent teeth that emerge.

  6. Multiple Unerupted Permanent Teeth Associated with Noonan ...

    African Journals Online (AJOL)

    [2] Oral findings in patients with NS include a high arched palate ... the atypical dental anomalies such as multiple unerupted permanent ... clinical features in a child with NS. .... Disabilities, Centers for Disease Control and Prevention (CDC).

  7. Hymenal stenosis and fibrosis in two adult women.

    Science.gov (United States)

    Goldstein, Andrew T; Todd, Sarah; Bedell, Sarah; Tabbarah, Abeer

    2015-05-01

    Hymenal abnormalities are most commonly a result of incomplete apoptosis of the urogenital sinus during embryology. Infrequently, however, noncongenital abnormalities of the hymen can occur that can cause significant sequelae such as severe introital dyspareunia. We report on two adult women who developed severe introital dyspareunia secondary to hymenal stenosis and fibrosis in the absence of other vulvovaginal pathology. Neither woman had point tenderness of the vulvar vestibule, but their symptoms of searing pain on vaginal penetration was reproduced by stretching the hymen with two fingers. In both cases, conservative treatments with vaginal dilators in combination with topical hormonal therapy failed to relieve their symptoms, but both women were subsequently successfully treated with hymenectomy. Hymenal stenosis and fibrosis can develop in the absence of identifiable vulvar dermatoses. If conservative treatment with topical hormonal therapy and vaginal dilators is unsuccessful, hymenectomy can restore normal coital function.

  8. In vivo MR perfusion imaging of renal artery stenosis

    International Nuclear Information System (INIS)

    Powers, T.; Lorenz, C.H.; Bain, R.; Holburn, G.; Price, R.R.

    1989-01-01

    Various techniques have been developed for noninvasive evaluation of renal blood flow. More important in the assessment of potential renal ischemia may be actual perfusion of the nephron mass. MR pulse sequences have been devised that allow perfusion imaging (PI) in a dog model of renal artery stenosis. Unilateral renal artery stenosis was created in mongrel dogs and quantitation of renal blood flow was obtained with radioactive microspheres. Perfusion imaging was performed on a 1.5-T system to obtain the apparent diffusion coefficient. During initial studies, it was found that the usual gradient factor used in brain PI was too high for renal studies; a factor of < 50 was found to be optimal. Additionally, respiratory gating with acquisition at end expiration was necessary to prevent renal motion. Recent studies have shown that PI reflects the asymmetry of flow in this model

  9. Lumbar Spinal Stenosis: Who Should Be Fused? An Updated Review

    Science.gov (United States)

    Hasankhani, Ebrahim Ghayem; Ashjazadeh, Amir

    2014-01-01

    Lumbar spinal stenosis (LSS) is mostly caused by osteoarthritis (spondylosis). Clinically, the symptoms of patients with LSS can be categorized into two groups; regional (low back pain, stiffness, and so on) or radicular (spinal stenosis mainly presenting as neurogenic claudication). Both of these symptoms usually improve with appropriate conservative treatment, but in refractory cases, surgical intervention is occasionally indicated. In the patients who primarily complain of radiculopathy with an underlying biomechanically stable spine, a decompression surgery alone using a less invasive technique may be sufficient. Preoperatively, with the presence of indicators such as failed back surgery syndrome (revision surgery), degenerative instability, considerable essential deformity, symptomatic spondylolysis, refractory degenerative disc disease, and adjacent segment disease, lumbar fusion is probably recommended. Intraoperatively, in cases with extensive decompression associated with a wide disc space or insufficient bone stock, fusion is preferred. Instrumentation improves the fusion rate, but it is not necessarily associated with improved recovery rate and better functional outcome. PMID:25187873

  10. Bilateral renal dysplasia, nephroblastomatosis, and bronchial stenosis. A new syndrome?

    Science.gov (United States)

    Rodriguez, Maria Matilde; Correa-Medina, Mayrin; Whittington, Elizabeth E

    2015-06-01

    Bilateral nephroblastomatosis (NB) is an uncommon renal anomaly characterized by multiple confluent nephrogenic rests scattered through both kidneys, with only a limited number of cases reported in the medical literature. Some of these children may have associated either Perlman or Beckwith-Wiedemann syndrome and others do not demonstrate syndromic features. We report a full-term boy with anteverted nose, bilateral bronchial stenosis due to lack of cartilage, bilateral obstructive renal dysplasia and NB with glomeruloid features. The infant had visceromegaly, but neither gigantism nor hemihypertrophy. Immunohistochemistry for PAX2 (Paired box gene-2) and WT-1 (Wilms Tumor 1) were strongly positive in the areas of NB. GLEPP-1 (Glomerular Epithelial Protein) did not stain the areas of NB with a glomeruloid appearance, but was positive in the renal glomeruli as expected. We found neither associated bronchial stenosis nor the histology of NB resembling giant glomeruli in any of the reported cases of NB.

  11. Left Atrial Systolic Force in Asymptomatic Aortic Stenosis

    DEFF Research Database (Denmark)

    Cioffi, Giovanni; Cramariuc, Dana; Dalsgaard, Morten

    2011-01-01

    LASF in the total study population was 21 ± 14 kdynes/cm(2) . The determinants of LASF were higher age, heart rate, body mass index, systolic blood pressure, left ventricular (LV) mass, mitral peak early velocity, maximal LA volume, and longer mitral deceleration time (multiple R(2) = 0.37, P ...Background: There is a limited knowledge about left atrial (LA) systolic force (LASF) and its key determinants in patients with asymptomatic mild-moderate aortic stenosis (AS). Methods: We used baseline clinic and echocardiographic data from 1,566 patients recruited in the simvastatin ezetimibe...... in aortic stenosis study evaluating the effect of placebo-controlled combined simvastatin and ezetimibe treatment in asymptomatic AS. The LASF was calculated by Manning's method. Low and high LASF were defined as 95th percentile of the distribution within the study population, respectively. Results: Mean...

  12. Stents in Renal Artery Bifurcation Stenosis: A Case Report

    Directory of Open Access Journals (Sweden)

    Polytimi Leonardou

    2011-01-01

    Full Text Available A 39-year-old patient presented with poorly controlled hypertension, and she was referred to renal angiogram and potential renal angioplasty. Renal angiogram showed a bifurcation lesion of the right renal artery. A guide wire was used to cross the upper branch, while the lower branch was protected by another same-type guide wire through the same introducer. Two thin monorail balloons were used to dilate the two branches; however, despite balloon dilatation, the stenosis of the vessels persisted. The “kissing balloon” technique was then attempted by simultaneously inflating both branches using the same balloons, but more than a 70% residual stenosis persisted in each branch. Two stents were finally placed in a “kissing” way through the main renal artery. The imaging and clinical results were good, without any procedure-related complications. Three years clinical followup was also good, without any reason for further interventional approach.

  13. Stents in Renal Artery Bifurcation Stenosis: A Case Report

    Science.gov (United States)

    Leonardou, Polytimi; Pappas, Paris

    2011-01-01

    A 39-year-old patient presented with poorly controlled hypertension, and she was referred to renal angiogram and potential renal angioplasty. Renal angiogram showed a bifurcation lesion of the right renal artery. A guide wire was used to cross the upper branch, while the lower branch was protected by another same-type guide wire through the same introducer. Two thin monorail balloons were used to dilate the two branches; however, despite balloon dilatation, the stenosis of the vessels persisted. The “kissing balloon” technique was then attempted by simultaneously inflating both branches using the same balloons, but more than a 70% residual stenosis persisted in each branch. Two stents were finally placed in a “kissing” way through the main renal artery. The imaging and clinical results were good, without any procedure-related complications. Three years clinical followup was also good, without any reason for further interventional approach. PMID:21789043

  14. Prematurity Affects Age of Presentation of Pyloric Stenosis.

    Science.gov (United States)

    Costanzo, Caitlyn M; Vinocur, Charles; Berman, Loren

    2017-02-01

    Term infants with hypertrophic pyloric stenosis (HPS) typically present between 4 and 6 weeks. There is limited consensus, however, regarding age of presentation of premature infants. We aim to determine if there is an association between the degree of prematurity and chronological age of presentation of HPS. A total of 2988 infants who had undergone a pyloromyotomy for HPS were identified from the 2012 and 2013 NSQIP-P Participant Use Files. Two hundred seventeen infants (7.3%) were born prematurely. A greater degree of prematurity was associated with an older chronological age of presentation ( P Prematurity was significantly associated with an increase in overall postoperative morbidity, reintubation, readmission, and postoperative length of stay. When clinicians evaluate an infant with nonbilious emesis with a history of prematurity, they should consider pyloric stenosis if the calculated postconceptional age is between 44 and 50 weeks. When counseling families of premature infants, surgeons should discuss the increased incidence of postpyloromyotomy morbidity.

  15. Radiation-induced bilateral common carotid artery stenosis

    International Nuclear Information System (INIS)

    Kobayashi, Nobuaki; Nakagawa, Yoku; Tashiro, Kunio; Abe, Hiroshi

    1986-01-01

    A case of radiation-induced bilateral common carotid artery stenosis is reported. This 60 years old housewife was hospitalized in 1982 because of sudden onset of mild left hemiparesis. Twenty-five years ago, she underwent radiation therapy of approximately 5,000 rads to the anterior cervical region because of thyroid cancer. Angiograms in 1982 revealed bilateral common carotid artery stenosis, especially in the right common carotid artery, the legion of which were included within the field of radiation performed in 1952. Right thromboendarterectomy was performed in 1983. At operation, slight periarterial fibrosis with calcified arteriosclerotic change was found, and dissection between the thickened intima and the media was not so difficult. Histological change of resected thromboendarterium was similar to the one observed in the pure arteriosclerotic disease. (author)

  16. Valve Calcification in Aortic Stenosis: Etiology and Diagnostic Imaging Techniques

    Directory of Open Access Journals (Sweden)

    María Manuela Izquierdo-Gómez

    2017-01-01

    Full Text Available Aortic stenosis is the most common valvulopathy in the Western world. Its prevalence has increased significantly in recent years due to population aging; hence, up to 8% of westerners above the age of 84 now have severe aortic stenosis (Lindroos et al., 1993. This causes increased morbidity and mortality and therein lies the importance of adequate diagnosis and stratification of the degree of severity which allows planning the best therapeutic option in each case. Long understood as a passive age-related degenerative process, it is now considered a rather more complex entity involving mechanisms and factors similar to those of atherosclerosis (Stewart et al., 1997. In this review, we summarize the pathophysiological mechanisms underlying the onset and progression of the disease and analyze the current role of cardiac imaging techniques for diagnosis.

  17. Spinal canal stenosis at the level of Atlas

    Directory of Open Access Journals (Sweden)

    Suchanda Bhattacharjee

    2011-01-01

    Full Text Available We report here a rare case of high cervical stenosis at the level of atlas who presented with progressively deteriorating quadriparesis and respiratory distress. A 10-year-old boy presented with above symptoms of one-year duration with a preceding history of trivial trauma prior to onset of such symptoms. Cervical spine MRI revealed a significant stenosis at the level of atlas from the posterior side with a syrinx extending above and below. High-resolution computed tomography of the above level yielded an ill-defined osseous bar compressing the canal at the level of C 1 posterior arch, which appeared bifid in the midline. The patient was immediately taken up for surgery in view of his respiratory complaints. The child showed an excellent recovery after excision of the posterior arch of atlas and removal of the compressing osseous structure.

  18. Endoscopic management of posttraumatic supraglottic stenosis in the pediatric population.

    LENUS (Irish Health Repository)

    Oosthuizen, Johannes Christiaan

    2012-02-01

    OBJECTIVES: Pediatric blunt laryngeal trauma is a rare and potentially life-threatening entity. External injuries can be misleading, and a high index of suspicion, as well as early intervention, is essential to achieve the best possible outcome. The authors of this report review the management of blunt laryngeal trauma in the pediatric population and describe the endoscopic management of posttraumatic supraglottic stenosis. METHODS: Methods used were case report from a tertiary referral institution and review of the literature. RESULTS: We describe the case of a 13-year-old girl whom developed supraglottic stenosis following blunt laryngeal trauma. Innovative endoscopic techniques were used in the successful management of this exceedingly rare entity. CONCLUSION: Early recognition and intervention are of paramount importance if successful endoscopic management of blunt laryngeal trauma is to be considered.

  19. Cone pathway function in relation to asymmetric carotid artery stenosis

    DEFF Research Database (Denmark)

    Kofoed, Peter Kristian; Munch, Inger Christine; Holfort, Stig K

    2013-01-01

    Purpose:  To examine retinal function in relation to retinal perfusion pressure in patients with carotid artery stenosis. Methods:  Thirteen patients with carotid artery stenosis without clinical eye disease underwent assessment of ophthalmic artery systolic blood pressure (OSP) by ocular...... pneumoplethysmography, carotid artery obstructive disease by ultrasonography, intraocular pressure by applanation tonometry, retinal perfusion by fluorescein angiography and retinal function by multifocal electroretinography (mfERG). Data analysis compared the eye on the most stenotic side with the fellow eye...... pressure (p = 0.0028, 0.011, 0.041 for N1, P1, N2 implicit times, respectively, and p = 0.0086, 0.016, 0.040 for N1, P1, N2 for amplitudes, respectively, corrected for OSP). Conclusion:  Cone function deviation was observed in clinically healthy eyes on the side with highest degree of carotid artery...

  20. How to measure renal artery stenosis - a retrospective comparison of morphological measurement approaches in relation to hemodynamic significance

    International Nuclear Information System (INIS)

    Andersson, Malin; Jägervall, Karl; Eriksson, Per; Persson, Anders; Granerus, Göran; Wang, Chunliang; Smedby, Örjan

    2015-01-01

    Although it is well known that renal artery stenosis may cause renovascular hypertension, it is unclear how the degree of stenosis should best be measured in morphological images. The aim of this study was to determine which morphological measures from Computed Tomography Angiography (CTA) and Magnetic Resonance Angiography (MRA) are best in predicting whether a renal artery stenosis is hemodynamically significant or not. Forty-seven patients with hypertension and a clinical suspicion of renovascular hypertension were examined with CTA, MRA, captopril-enhanced renography (CER) and captopril test (Ctest). CTA and MRA images of the renal arteries were analyzed by two readers using interactive vessel segmentation software. The measures included minimum diameter, minimum area, diameter reduction and area reduction. In addition, two radiologists visually judged the diameter reduction without automated segmentation. The results were then compared using limits of agreement and intra-class correlation, and correlated with the results from CER combined with Ctest (which were used as standard of reference) using receiver operating characteristics (ROC) analysis. A total of 68 kidneys had all three investigations (CTA, MRA and CER + Ctest), where 11 kidneys (16.2 %) got a positive result on the CER + Ctest. The greatest area under ROC curve (AUROC) was found for the area reduction on MRA, with a value of 0.91 (95 % confidence interval 0.82–0.99), excluding accessory renal arteries. As comparison, the AUROC for the radiologists’ visual assessments on CTA and MRA were 0.90 (0.82–0.98) and 0.91 (0.83–0.99) respectively. None of the differences were statistically significant. No significant differences were found between the morphological measures in their ability to predict hemodynamically significant stenosis, but a tendency of MRA having higher AUROC than CTA. There was no significant difference between measurements made by the radiologists and measurements made with

  1. Magnetic spring based on two permanent magnets

    International Nuclear Information System (INIS)

    Tsivilitsin, V.Yu.; Mil'man, Yu.V.; Goncharuk, V.A.; Bondar, I.B.

    2011-01-01

    A new type of the magnetic spring construction 'two permanent magnets' has been considered. A mathematical expression for the estimation of a pulling-in force has been offered. This expression is verified experimentally on the produced operating magnetic spring. The theoretical and experimental data are in good accordance. A number of advantages of the magnetic spring over the construction 'permanent magnet - magnetic circuit' such as an insignificant friction force between two magnets and a higher pulling force are discussed.

  2. Permanent Magnet Dipole for DIRAC Design Report

    CERN Document Server

    Vorozhtsov, Alexey

    2012-01-01

    Two dipole magnets including one spare unit are needed for the for the DIRAC experiment. The proposed design is a permanent magnet dipole. The design based on Sm2Co17 blocks assembled together with soft ferromagnetic pole tips. The magnet provides integrated field strength of 24.6 10-3 T×m inside the aperture of 60 mm. This Design Report summarizes the main magnetic and mechanic design parameters of the permanent dipole magnets.

  3. Renal vein oxygen saturation in renal artery stenosis

    DEFF Research Database (Denmark)

    Nielsen, K; Rehling, M; Henriksen, Jens Henrik Sahl

    1992-01-01

    Renal vein oxygen-saturation was measured in 56 patients with arterial hypertension and unilateral stenosis or occlusion of the renal artery. Oxygen-saturation in blood from the ischaemic kidney (84.4%, range 73-93%) was significantly higher than that from the 'normal' contralateral kidney (81...... than its blood flow. This is probably due to decreased filtration fraction and filtered sodium with subsequent reduction in absolute tubular re-absorption of sodium ions....

  4. Differentiation of benign and malignant hilar bile duct stenosis.

    Science.gov (United States)

    Liu, Xiaolei; Yang, Zhiying; Tan, Haidong; Shao, Chen; Liu, Liguo; Si, Shuang; Xu, Li; Sun, Yongliang

    2016-06-15

    Failure to differentiate benign and malignant hilar bile duct stenosis may lead to inappropriate treatment. We retrospectively analyzed the methods for differentiation. A total of 53 patients with hilar bile duct stenosis were included, comprising 41 malignant cases (hilar cholangiocarcinoma) and 12 benign cases (six primary sclerosing cholangitis and six IgG4-associated sclerosing cholangitis). Data of clinical histories, laboratory tests, imaging studies, and liver pathologies were collected, and comparison was made between benign and malignant groups. Compared with malignant group, patients in the benign group were more likely to have multiorgan involvement of clinical histories (P < 0.001). There was no difference on bilirubin, liver enzyme, and serum tumor marker between the two groups, whereas serum IgG4 levels were higher in the benign group (P = 0.003). Patients in the benign group were more likely to have pancreatic changes (P < 0.001) and multiple-segmental bile duct stenosis (P < 0.001) on imaging. Compared with the malignant group, patients in the benign group were more likely to show severe periportal inflammation in noninvolved liver (P < 0.001), fibrosis around intrahepatic bile duct (P < 0.001), and more IgG4-positive plasma cells (P < 0.001) on liver pathology. Benign lesion should be considered for patients with history of multiorgan involvement, pancreas changes, or multiple-segmental bile duct stenosis on imaging. Liver biopsy could be helpful for differential diagnosis before surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. How to manage hypertension with atherosclerotic renal artery stenosis?

    Science.gov (United States)

    Ricco, Jean-Baptiste; Belmonte, Romain; Illuminati, Guilio; Barral, Xavier; Schneider, Fabrice; Chavent, Bertrand

    2017-04-01

    The management of atherosclerotic renal artery stenosis (ARAS) in patients with hypertension has been the topic of great controversy. Major contemporary clinical trials such as the Cardiovascular Outcomes for Renal Artery lesions (CORAL) and Angioplasty and Stenting for Renal Atherosclerotic lesions (ASTRAL) have failed to show significant benefit of revascularization over medical management in controlling blood pressure and preserving renal function. We present here the implications and limitations of these trials and formulate recommendations for management of ARAS.

  6. Treatment of distal bronchial stenosis after bilateral lung transplantation

    Directory of Open Access Journals (Sweden)

    S. V. Golovinskiy

    2017-01-01

    Full Text Available The effi ciency of lung transplantation is considerably limited by the complications associated with the bronchial pathologies. Despite the progress of the treatment methods, bronchial complications are still remaining as an actual problem in the postoperative period with frequency of occurrence from 7 to 29%. However, the bronchial stenosis are the most common bronchial complications after lung transplantation with mortality from 2 to 4%.Aim. To study an experience of our center of bronchial stenosis treatment in lung recipients. Materials and methods. 34 patients underwent lung transplantation from September 2014 to January 2017. 6 (16% of them had a stenosis of lobar or segmental bronchi from 84 to 494 postoperative day. 5 (83% of them have demonstrated multifocal lesions. In all of the cases there was performed an endoscopic bougienage, which involved a balloon dilatation and electrocoagulated incision of granular tissue under X-ray control. After that the patients were administrated by everolimus.Results. Restenosis was formed in 132,0 ± 94,2 postoperative day after primary treatment in all patients. In four cases (67% we used nitinol stent placement under X-ray control. There were no complications. In 3 cases stents were dislocated distally, so we needed to use repeated endoscopic bougienage to replace the stent. Using of everolimus has allowed to decrease the rate of restenosis, but it need future research.Conclusion. Distal bronchial stenosis after lung transplantation can be managed with endoscopic bougienage and stent placement. Adding everolimus has not signifi cantly affected the risk of frequency of restenosis.

  7. computed tomography of vertebrobasilar artery stenosis and thrombosis

    International Nuclear Information System (INIS)

    Hamaguchi, Naoki; Takusagawa, Yoshihiko; Fujiwara, Kenta; Yamamoto, Kurou; Okada, Keisei

    1980-01-01

    CT findings of 6 patients with vertebrobasilar artery stenosis or thrombosis were described. CT findings of these diseases were hardly obtained, in spite of severe cloudings of consciousness, within 24 hours after the onset. After 24 hours showed low density areas in the cerebellum and posterior cerebral artery of occipital lobe and scattering low density areas were observed in many cases with hemispherium cerebelli. Pontine focuses were visualized only in 3 cases. (Tsunoda, M.)

  8. Investigation into drivers of cost of stenting for carotid stenosis.

    Science.gov (United States)

    Rinaldo, Lorenzo; Brinjikji, Waleed; Cloft, Harry; DeMartino, Randall R; Lanzino, Giuseppe

    2017-09-01

    We aimed to identify factors associated with cost of carotid artery stenting (CAS). Patient and hospital characteristics affecting cost of admission for CAS were identified using the Vizient national database of hospital-reported outcomes. Patients who underwent CAS for either asymptomatic or symptomatic carotid stenosis were identified using surgical Medicare Severity-Diagnosis Related Groups and appropriate International Classification of Diseases, Ninth Revision and Tenth Revision codes. There were 166 hospitals that reported outcomes from 7369 inpatient admissions for CAS. Each institution reported a mean value for cost related to patient care per admission for CAS; the average cost across all reporting institutions was $12,834.14 (standard error of the mean [SEM], 492.88). Institutions in the lowest 25th percentile with respect to frequency of intensive care unit admission after CAS had lower cost of admission than institutions above the 75th percentile ($10,971.30 [SEM, 460.67] vs $14,992.90 [964.29]; P = .002), without any differences in incidence of stroke during admission (2.2% [SEM, 0.3] vs 2.0% [0.4]; P = .877) or 30-day readmission (1.9% [SEM, 0.4] vs 2.5 [0.6]; P = .329). Admissions for patients with symptomatic stenosis were more expensive than those with asymptomatic stenosis ($20,462.10 [SEM, 819.93] vs $11,285.20 [347.11]; P costs of admission ($14,176.20 [SEM, 597.13] vs $12,287.10 [395.73]; P care unit, symptomatic stenosis, and obesity were associated with increased costs in patients undergoing CAS. These data may aid in identifying opportunities to improve the cost-effectiveness of this procedure. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  9. Outcome of endovascular treatment in symptomatic intracranial vascular stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Dae Chul; Kim, Sang Joon; Lee, Duk Hee; Kim, Won; Choi, Choong Gon; Lee, Jeong Hyun; Kwon, Sun Uck; Kim, Jong Sung [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, Hyun Jeong [Daejeon Catholic Hospital, Daejeon (Korea, Republic of)

    2005-03-15

    The outcome evaluation for the revascularization of intracranial vascular stenoses has not been fully described due to the highly technical nature of the procedure. We report here on the early and late clinical outcome of angioplasty and/or stenting of symptomatic severe intracranial vascular stenoses at a single institute. Since 1995, we have treated 35 patients with symptomatic intracranial vascular stenosis (more than 70% stenosis, mean stenosis: 78.6% {+-} 6.2%). Angioplasty (n = 19) was performed for the horizontal segment of the middle cerebral artery (M1) (n = 16) and the basilar artery (BA) (n = 1), the intradural vertebral artery (VA) (n = 1), and the cavernous internal carotid artery (ICA) (n = 1). Stenting (n = 16) was performed for the cavernous or petrous ICAs (n = 9), the intradural VA (n = 3), BA (n = 2), and M1 (n = 2) artery. We assessed the angiographic success (defined as residual stenosis < 50%) rate, the periprocedural complications during the 30-day periprocedural period, the symptomatic recurrence and restenosis during a mean 22-month follow-up (FU) period. The Kaplan-Meier estimate of the cumulative even-free rate of the major cerebrovascular events, i.e. death, stroke or restenosis, was also done. Angiographic success was achieved in 97% of our patients (34/35). There were four procedure-related complications (11%) including a death and a minor stroke. During the mean 22-month FU, the asymptomatic restenosis rate was 9% and the symptomatic restenosis rate was 6% in the target lesion and 9% in all the vascular territories. The Kaplan-Meier estimate was 70.6% (95% confidence interval = 46.5-94.7) after 33 month of FU. In addition to a high angiographic success rate and an acceptable periprocedural complication rate, intracranial angioplasty and/or stenting revealed a relatively low symptomatic recurrence rate. Hemorrhage is a rare, but the physician must aware that potentially fatal periprocedural complications can occur.

  10. Langtidskomplikationer efter injektion af permanent vaevsfylder i laeber

    DEFF Research Database (Denmark)

    Sneistrup, Christian; Hölmich, Lisbet Rosenkrantz; Dahlstrøm, Karin

    2009-01-01

    We present two cases with signs of infection and granulomas seen years after injection of permanent fillers to the lips. These side effects are difficult to treat. They resemble an immunological foreign body response and late-onset infection as well as granuloma and scaring depending on the subst......We present two cases with signs of infection and granulomas seen years after injection of permanent fillers to the lips. These side effects are difficult to treat. They resemble an immunological foreign body response and late-onset infection as well as granuloma and scaring depending...... on the substance injected. Steroid injections are indicated in case of granuloma, and antibiotics should be used when infection occurs, but surgical excision can be required. It is important to emphasize this condition in order to give patients proper advice prior to treatment and to recognize symptoms....

  11. Hanford Permanent Isolation Barrier Program: Asphalt technology test plan

    International Nuclear Information System (INIS)

    Freeman, H.D.; Romine, R.A.

    1994-05-01

    The Hanford Permanent Isolation Barriers use engineered layers of natural materials to create an integrated structure with backup protective features. The objective of current designs is to develop a maintenance-free permanent barrier that isolates wastes for a minimum of 1000 years by limiting water drainage to near-zero amounts. Asphalt is being used as an impermeable water diversion layer to provide a redundant layer within the overall barrier design. Data on asphalt barrier properties in a buried environment are not available for the required 100-year time frame. The purpose of this test plan is to outline the activities planned to obtain data with which to estimate performance of the asphalt layers

  12. Langtidskomplikationer efter injektion af permanent vaevsfylder i laeber

    DEFF Research Database (Denmark)

    Sneistrup, Christian; Hölmich, Lisbet Rosenkrantz; Dahlstrøm, Karin

    2009-01-01

    We present two cases with signs of infection and granulomas seen years after injection of permanent fillers to the lips. These side effects are difficult to treat. They resemble an immunological foreign body response and late-onset infection as well as granuloma and scaring depending on the subst......We present two cases with signs of infection and granulomas seen years after injection of permanent fillers to the lips. These side effects are difficult to treat. They resemble an immunological foreign body response and late-onset infection as well as granuloma and scaring depending...... on the substance injected. Steroid injections are indicated in case of granuloma, and antibiotics should be used when infection occurs, but surgical excision can be required. It is important to emphasize this condition in order to give patients proper advice prior to treatment and to recognize symptoms...

  13. Hanford Permanent Isolation Barrier Program: Asphalt technology test plan

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, H.D.; Romine, R.A.

    1994-05-01

    The Hanford Permanent Isolation Barriers use engineered layers of natural materials to create an integrated structure with backup protective features. The objective of current designs is to develop a maintenance-free permanent barrier that isolates wastes for a minimum of 1000 years by limiting water drainage to near-zero amounts. Asphalt is being used as an impermeable water diversion layer to provide a redundant layer within the overall barrier design. Data on asphalt barrier properties in a buried environment are not available for the required 100-year time frame. The purpose of this test plan is to outline the activities planned to obtain data with which to estimate performance of the asphalt layers.

  14. A variable-field permanent-magnet dipole for accelerators

    International Nuclear Information System (INIS)

    Kraus, R.H. Jr.; Barlow, D.B.; Meyer, R.

    1992-01-01

    A new concept for a variable-field permanent-magnet dipole has been developed and fabricated at Los Alamos. The application requires an extremely uniform dipole field in the magnet aperture and precision variability over a large operating range. An iron-core permanent- magnet design using a shunt that was specially shaped to vary the field in a precise and reproducible fashion with shunt position. The key to this design is in the shape of the shunt. The field as a function of shunt position is very linear from 90% of the maximum field to 20% of the minimum field. The shaped shunt also results in a small maximum magnetic force attracting the shunt to the yoke allowing a simple mechanical design. Calculated and measured results agree well for the magnet

  15. EDITORIAL: Permanent revolution - or evolution?

    Science.gov (United States)

    Dobson, Ken

    1998-03-01

    Honorary Editor It was that temporary Bolshevik Leon Trotsky who developed the principle of `permanent revolution', a principle that perhaps characterizes the recent history of education in (south) Britain more than does, say, principles traditionally associated with the Conservative or Labour parties. As this editorial is being written, changes are being made to primary school education, and the long-awaited details of the post-Dearing reorganizing of post-16 education are yet to hit the overful bookshelves and filing cabinets of school heads and examination board officials. But something unique has happened recently which might have surprised even Trotsky. The Secretary of State for Education has set up targets for primary school pupils' attainment and threatened (or promised) to resign if they are not met within the lifetime of our newly elected parliament. Of course, if Mr Blunkett is still in a position to resign at that stage he will have been the longest serving Secretary of State since time immemorial. But we should not carp: this is truly a revolutionary idea. Not the promise to resign - although this idea is not so fashionable now as it once was. The revolutionary idea is that a major change to an educational process is actually being made that carries with it a predicted and testable outcome. By contrast, when school physics was refreshed a generation ago by the introduction of Nuffield courses at both pre- and post-16 stages, no `targets' were set. I and many other physics teachers certainly preferred teaching these to teaching their predecessor syllabuses, and might even dare to assert that the pupils liked them too. But we still don't really know whether or not they learned more - or even better - physics. Very little happened as far as the outside world was concerned: the usual fraction of students gave up physics at the usual ages, and those who were examined didn't really get a better reward for their more up-to-date and more enjoyably learned

  16. Workplace bullying a risk for permanent employees.

    Science.gov (United States)

    Keuskamp, Dominic; Ziersch, Anna M; Baum, Fran E; Lamontagne, Anthony D

    2012-04-01

    We tested the hypothesis that the risk of experiencing workplace bullying was greater for those employed on casual contracts compared to permanent or ongoing employees. A cross-sectional population-based telephone survey was conducted in South Australia in 2009. Employment arrangements were classified by self-report into four categories: permanent, casual, fixed-term and self-employed. Self-report of workplace bullying was modelled using multiple logistic regression in relation to employment arrangement, controlling for sex, age, working hours, years in job, occupational skill level, marital status and a proxy for socioeconomic status. Workplace bullying was reported by 174 respondents (15.2%). Risk of workplace bullying was higher for being in a professional occupation, having a university education and being separated, divorced or widowed, but did not vary significantly by sex, age or job tenure. In adjusted multivariate logistic regression models, casual workers were significantly less likely than workers on permanent or fixed-term contracts to report bullying. Those separated, divorced or widowed had higher odds of reporting bullying than married, de facto or never-married workers. Contrary to expectation, workplace bullying was more often reported by permanent than casual employees. It may represent an exposure pathway not previously linked with the more idealised permanent employment arrangement. A finer understanding of psycho-social hazards across all employment arrangements is needed, with equal attention to the hazards associated with permanent as well as casual employment. © 2012 The Authors. ANZJPH © 2012 Public Health Association of Australia.

  17. Complications in percutaneous transluminal stenting for carotid artery stenosis

    International Nuclear Information System (INIS)

    Li Shenmao; Miao Zhongrong; Zhu Fengshui; Ji Xunming; Jiao Liqun; Qi Jianshu; Ling Feng

    2007-01-01

    Objective: To discuss the complications of endovascular stenting for carotid artery stenosis. Methods: Cerebral vascular angiography and cervical Doppler sonography were performed in 648 patients with carotid artery stenosis. Emboli-protected device was used in 365 patients and none in 283 patients. Results: All 648 patients were technically successful (100%). Symptoms disappeared or improved in 78.7% patients. Slow heart rate during operation existed in 26.4% patients. Embolism caused by dislodgment of emboli occurred in 5 patients, 3 of them recovered after treatment and 2 had unilateral dyskinesias. Intracranial hemorrhage occurred in 3 patients. Stroke or death within 30 days after operation occurred in 6 patients(1.24%). 322 patients (77.8%)were followed up. Restenosis occurred in 17 patients(3.3%). Conclusion: Percutaneous transluminal stenting is a safe option for carotid artery stenosis. Correct evaluation of clinical and angiographic data before operation, together with normative manipulation and nursing during and after operation are the key points to avoid complications. (authors)

  18. Association between plasma homocysteine concentrations and extracranial carotid stenosis

    International Nuclear Information System (INIS)

    Mousavi, Seyed Ali; Ghasemi, M.; Hoseini, T.

    2006-01-01

    Increasing epidemiologic data support a relationship between elevated plasma total homocysteine levels and an increased risk for vascular disease. Higher plasma total homocysteine (tHcy) levels have been associated with extracranial carotid atherosclerosis and cerebral infarction in whites. However, data regarding such associations are limited for Asians. This study examined the association between tHcy level and carotid stenosis in Iranian subjects. In this retrospective study, the subjects were 158 patients with ischemic stroke, including 105 with a normal tHcy level and 53 with a high tHcy level. We investigated the extracranial carotid arteries by ultrasonography and measured serum tHcy by ELISA method in these two groups. We found no meaningful association between a high tHcy level and carotid stenosis. The lack of any meaningful difference in carotid stenosis between patients with normal and elevated tHcy levels is probably due to the low frequency of extracranial diseases in the Asian population and to the nature of homocysteine atherosclerosis. (author)

  19. Hepatic artery stenosis in liver transplantation: Imaging and interventional treatment

    International Nuclear Information System (INIS)

    Rinaldi, Pierluigi; Inchingolo, Riccardo; Giuliani, Michela; Di Stasi, Carmine; De Gaetano, Anna Maria; Maresca, Giulia; Bonomo, Lorenzo

    2012-01-01

    Introduction: Main purpose of our study is to demonstrate the spectral and color Doppler ultrasonography (DUS) findings that would indicate hepatic artery stenosis (HAS) after liver transplantation and to report our single center results. Moreover we want to establish role and limits of the different imaging techniques in detecting HAS, proposing a non invasive diagnostic approach and to depict indications and feasibility of endovascular treatment in the single patient. Materials and methods: Our study consisted of 222 patients who underwent liver transplantation between January 1999 and December 2009. DUS findings were correlated with multidetector computed tomography angiography (MDCTA) and angiographic results. Results: HAS occurred in 21 cases (9.5%). In all cases diagnosis was performed by DUS. MDCTA quantified stenosis and showed an overall picture of splanchnic vascularization. Based on DUS and MDCTA data integration, in 9 cases we adopted the “wait and see” strategy. Moreover in 12 cases treatment was considered necessary. For hepatic artery stenosis, use of DUS criteria resulted in a sensitivity of 100% (20/20), a specificity of 99.5% (201/202), a positive predictive value (PPV) of 95% (20/21), and negative predictive value (NPV) of 100% (201/201), and an overall accuracy of 99.5% (221/222). Conclusion: Our study underline the role of DUS in early diagnosis of HAS: repeated evaluation of both direct and indirect signs increases NPV and sensitivity of DUS.

  20. Carotid stenosis: a comparison between MR and spiral CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Magarelli, N.; Carriero, A.; Bonomo, L. [Institute of Radiology, University ``G. D`Annunzio``, Chieti (Italy); Scarabino, T.; Simeone, A.L.; Florio, F. [IRCCS, Foggia (Italy); Salvolini, U. [Department of Neuroradiology, University of Ancona (Italy)

    1998-06-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.) With 6 figs., 4 tabs., 17 refs.

  1. Carotid stenosis: a comparison between MR and spiral CT angiography

    International Nuclear Information System (INIS)

    Magarelli, N.; Carriero, A.; Bonomo, L.; Scarabino, T.; Simeone, A.L.; Florio, F.; Salvolini, U.

    1998-01-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.)

  2. Diagnosis of lumbar central spinal stenosis by plain radiography

    International Nuclear Information System (INIS)

    Ilkko, E.

    1989-01-01

    The usefulness of plain radiography in the diagnosis of lumbar central spinal stenosis was studied in 116 patients using computed tomography (CT) as a reference. The most significant signs found in central spinal stenosis were short pedicles, high narrow intervertebral foramina, small interlaminar windows and deep posterior concavity of the vertebral bodies. The sensitivity of plain radiography in the diagnosis of central spinal stenosis as compared to CT was 66%, the specificity was 93% and the accuracy was 86%. The midsagittal and interpedicular diameters were measured from plain radiograms and were compared with corresponding CT diameters. In approximately half of the cases, the sagittal diameters were compatible. The maximum error was 6 mm. On average, the interpedicular distances were measured as too wide. The reliability of CT measurements were established by taking the measurements from the vertebral column of a moose calf, and then comparing these to the real measurements obtained with a calibrated ruler. The maximal differences were 2 mm. (author). 24 refs.; 8 figs.; 3 tabs

  3. Model of lumbar spinal stenosis in the experiment

    Directory of Open Access Journals (Sweden)

    Oleg Perepechai

    2015-07-01

      Abstracts The description of an experimental model of lumbar spinal stenosis on 20 rats. The experiment was symmetrical dissection of arc plates to the inside thin cortical layer plates, and then dissection of the latter. The middle part of the arc with the spinous processes of the vertebrae is separated from the rest of the arc, and articular processes. The separated middle part of the arc with yellow ligament is shifted in the ventral direction, reducing the size of the cavity of the spinal canal and fix the contacting bone edges with bone cement. Degenerative changes of the nerve roots were evaluated histologically by endoneural and epineural changes using a 7-point scale of G. Byrond and others. In the studied group of animals 7 days after spinal canal stenosis simulations appeared degenerative changes of nerve fibers, but the degree is low, and there is virtually no endoneural inflammation. The epineurium determined expressed or gross changes, indicating epineural inflammatory processes. After 1 month. There appeared dystrophic and degenerative changes of nerve fibers of the overwhelming majority (over 75%. At a later date (3 months, endoneural change remained practically the same as in the 1th month after surgery, epineural violations were preserved, there were groups and single fibroblasts as a sign of epineural fibrosis, as well as portions of connective tissue neoplasms and hyalinosis.   Keywords: lumbar spinal stenosis, an experimental model.

  4. Left coronary aneurysmal dilation and subaortic stenosis in a dog.

    Science.gov (United States)

    Hernandez, Juan L; Bélanger, Marie-Claude; Benoit-Biancamano, Marie-Odile; Girard, Christiane; Pibarot, Philippe

    2008-06-01

    A 6-month-old German shepherd dog was referred for evaluation of a cardiac murmur. Upon physical examination, the auscultated heart rate was 120 beats/min, and a grade IV/VI systolic heart murmur with a point of maximal intensity over the left heart base radiating up the neck was heard. The standard echocardiographic examination showed subaortic stenosis and an anechoic tubular structure extending from the sinus of Valsalva to the left ventricular posterior wall. Aneurysmal left coronary artery (CA) was confirmed by angiography. The dog was euthanized and post-mortem examination showed severe dilatation of the proximal left CA and confirmed the subaortic stenosis. Histopathology did not demonstrate abnormalities in the walls of the CA, aorta or pulmonary artery. The exact cause of the CA aneurysmal dilation remains unknown. Subaortic stenosis, elevated coronary vascular resistance or a congenital anomaly may have contributed to the dilation. To our knowledge, coronary aneurysmal dilation has never been described in dogs. Standard echocardiography provides reliable information on coronary anatomy.

  5. Recurrent Syncope Attributed to Left Main Coronary Artery Severe Stenosis

    Directory of Open Access Journals (Sweden)

    Min Li

    2015-01-01

    Full Text Available Patients with acute coronary syndrome (ACS rarely manifest as recurrent syncope due to malignant ventricular arrhythmia. We report a case of a 56-year-old Chinese male with complaints of paroxysmal chest burning sensation and distress for 2 weeks as well as loss of consciousness for 3 days. The electrocardiogram (ECG revealed paroxysmal multimorphologic ventricular tachycardia during attack and normal heart rhythm during intervals. Coronary angiograph showed 90% stenosis in left main coronary artery and 80% stenosis in anterior descending artery. Two stents sized 4.0*18 mm and 2.75*18 mm were placed at left main coronary artery and anterior descending artery, respectively, during percutaneous coronary intervention (PCI. The patient was discharged and never had ventricular arrhythmia again during a 3-month follow-up since the PCI. This indicated that ventricular tachycardia was correlated with persistent severe myocardial ischemia. Coronary vasospasm was highly suspected to be the reason of the sudden attack and acute exacerbation. PCI is recommended in patients with both severe coronary artery stenosis and ventricular arrhythmia. Removing myocardial ischemia may stop or relieve ventricular arrhythmia and prevent cardiac arrest.

  6. Balloon catheter dilatation for mitral stenosis and severe pulmonary hypertension

    International Nuclear Information System (INIS)

    Wang Manhong

    2002-01-01

    Objective: To determine the safety and efficacy of percutaneous balloon mitral valvuloplasty (PBMV) for patients with mitral stenosis and severe pulmonary hypertension, and to assess the changes in pulmonary systolic pressure during follow-up. Methods: Forty-two patients with rheumatic mitral stenosis and severe pulmonary hypertension (pulmonary systolic pressure > 75 mmHg) underwent PBMV using standard Inoue technique, and the changes in clinical functional status and echo Doppler pulmonary systolic pressure during follow-up were assessed. Results: PBMV was successful in 39 patients. Immediately after the procedure, mitral valve area increased from (0.83 +- 0.12) cm 2 to (1.75 +- 0.11) cm 2 , pulmonary systolic pressure decreased from (85 +- 7) mmHg to (61 +- 13) mmHg (all P < 0.001). Severe mitral regurgitation occurred in 3 patients, one of whom underwent mitral valve replacement. During follow-up (average 6 months), in 39 patients with successful PBMV, the clinical functional status was improved and pulmonary systolic pressure was further decreased despite unchanged mitral valve area. Conclusions: PBMV was safe and effective for patients with mitral stenosis and severe pulmonary hypertension. Clinical functional status was improved and pulmonary systolic pressure was continuously decreased during the short-term follow-up

  7. Amaurosis fugax: risk factors and prevalence of significant carotid stenosis

    Directory of Open Access Journals (Sweden)

    Kvickström P

    2016-10-01

    Full Text Available Pia Kvickström,1 Bertil Lindblom,2,3 Göran Bergström,4,5 Madeleine Zetterberg2,3 1Department of Ophthalmology, Skaraborg Hospital, Skövde, 2Department of Clinical Neuroscience/Ophthalmology, Institute of Neuroscience and Physiology, The Sahlgrenska Academy at University of Gothenburg, 3Department of Ophthalmology, Sahlgrenska University Hospital, Mölndal, 4Department of Molecular and Clinical Medicine, The Sahlgrenska Academy at University of Gothenburg, 5Department of Clinical Physiology, Sahlgrenska University Hospital, Gothenburg, Sweden Purpose: The purpose of this study was to describe clinical characteristics and prevalence of carotid stenosis in patients with amaurosis fugax (AF.Method: Patients diagnosed with AF and subjected to carotid ultrasound in 2004–2010 in Sahlgrenska University Hospital, Gothenburg (n=302, were included, and data were retrospectively collected from medical records.Results: The prevalence of significant carotid stenosis was 18.9%, and 14.2% of the subjects were subjected to carotid endarterectomy. Significant associations with risk of having ≥70% stenosis were male sex (adjusted odds ratio [aOR]: 2.62; 95% confidence interval [CI]: 1.26–5.46, current smoking (aOR: 6.26; 95% CI: 2.62–14.93, diabetes (aOR: 3.68; 95% CI: 1.37–9.90 and previous vasculitis (aOR: 10.78; 95% CI: 1.36–85.5. A majority of the patients (81.4% was seen by an ophthalmologist prior to the first ultrasound. Only 1.7% of the patients exhibited retinal artery emboli at examination.Conclusion: The prevalence of carotid stenosis among patients with AF is higher than has previously been demonstrated in stroke patients. An association with previously reported vascular risk factors and with vasculitis is seen in this patient group. Ocular findings are scarce. Keywords: amaurosis fugax, carotid stenosis, carotid ultrasound, giant cell arteritis, transient ischemic attack, transient monocular visual loss

  8. Recognition and treatment of outflow tract stenosis during and after endovascular exclusion for abdominal aortic aneurysm

    International Nuclear Information System (INIS)

    Lu Qingsheng; Jing Zaiping; Zhao Zhiqing; Bao Junmin; Zhao Jun; Feng Xiang; Feng Rui; Huang Sheng

    2003-01-01

    Objective: To study the cognition and treatment of outflow tract stenosis in and after endovascular exclusion for abdominal aortic aneurysm. Methods: From Mar 1997 to Oct 2002, in 136 patients undergoing abdominal aortic aneurysm endovascular exclusion, 8 patients had outflow tract stenosis during the operation, and 3 patients had outflow tract stenosis after operation. The stenosis of 5 patients occurred at the crotch of the graft-stent. PTA was done in 7 patients and stents were placed in stenotic segment in 2 patients. 2 patients were treated with crossover operation. Results: Following up 1 month to 2 years, all patients have no lower limbs ischemia. Conclusions: The diagnosis of outflow tract stenosis during and after abdominal endovascular exclusion for aortic aneurysm must be in time. The treatment should be according to the different causes of stenosis

  9. Influence of stenosis on hemodynamic parameters in the realistic left coronary artery under hyperemic conditions.

    Science.gov (United States)

    Kamangar, Sarfaraz; Badruddin, Irfan Anjum; Badarudin, A; Nik-Ghazali, N; Govindaraju, Kalimuthu; Salman Ahmed, N J; Yunus Khan, T M

    2017-03-01

    The current study investigates the hyperemic flow effects on heamodynamics parameters such as velocity, wall shear stress in 3D coronary artery models with and without stenosis. The hyperemic flow is used to evaluate the functional significance of stenosis in the current era. Patients CT scan data of having healthy and coronary artery disease was chosen for the reconstruction of 3D coronary artery models. The diseased 3D models of coronary artery shows a narrowing of >50% lumen area. Computational fluid dynamics was performed to simulate the hyperemic flow condition. The results showed that the recirculation zone was observed immediate to the stenosis and highest wall shear stress was observed across the stenosis. The decrease in pressure was found downstream to the stenosis as compared to the coronary artery without stenosis. Our analysis provides an insight into the distribution of wall shear stress and pressure drop, thus improving our understanding of hyperemic flow effect under both conditions.

  10. Effects of the Temporary Placement of a Self-Expandable Metallic Stent in Benign Pyloric Stenosis

    OpenAIRE

    Choi, Won Jae; Park, Jong-Jae; Park, Jain; Lim, Eun-Hye; Joo, Moon Kyung; Yun, Jae-Won; Noh, Hyejin; Kim, Sung Ho; Choi, Woo Seok; Lee, Beom Jae; Kim, Ji Hoon; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae

    2013-01-01

    Background/Aims The use of self-expandable metallic stents (SEMS) is an established palliative treatment for malignant stenosis in the gastrointestinal tract; therefore, its application to benign stenosis is expected to be beneficial because of the more gradual and sustained dilatation in the stenotic portion. We aimed in this prospective observational study to evaluate the efficacy and safety of temporary SEMS placement in benign pyloric stenosis. Methods Twenty-two patients with benign sten...

  11. Severe hypertension due to renal polar artery stenosis in an adolescent treated with coil embolization

    Energy Technology Data Exchange (ETDEWEB)

    Docx, Martine K. [Koningin Paola Kinderziekenhuis, Department of Paediatrics, Chronic Diseases and Hypertension, Antwerp (Belgium); Vandenberghe, Philippe [Koningin Paola Kinderziekenhuis, Department of Paediatric Cardiology, Antwerp (Belgium); Maleux, Geert [University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Gewillig, Marc [University Hospitals Leuven, Department of Paediatric Cardiology, Leuven (Belgium); Mertens, Luc [Hospital for Sick Children, Paediatric Cardiology, Toronto (Canada)

    2009-11-15

    A 12-year-old boy presented with severe arterial hypertension due to a severe subsegmental renal artery stenosis. Treatment consisted of selective embolization of the stenosed polar artery, which resulted in near normalization of the arterial pressures. Renal artery stenosis should always be considered, even in young adolescents, as a cause for arterial hypertension. Only selective angiography was able to demonstrate the subsegmental artery stenosis in this patient. (orig.)

  12. Severe hypertension due to renal polar artery stenosis in an adolescent treated with coil embolization

    International Nuclear Information System (INIS)

    Docx, Martine K.; Vandenberghe, Philippe; Maleux, Geert; Gewillig, Marc; Mertens, Luc

    2009-01-01

    A 12-year-old boy presented with severe arterial hypertension due to a severe subsegmental renal artery stenosis. Treatment consisted of selective embolization of the stenosed polar artery, which resulted in near normalization of the arterial pressures. Renal artery stenosis should always be considered, even in young adolescents, as a cause for arterial hypertension. Only selective angiography was able to demonstrate the subsegmental artery stenosis in this patient. (orig.)

  13. The Agency's permanent headquarters in the Donaupark

    International Nuclear Information System (INIS)

    1975-01-01

    Early in 1967 the Government of Austria announced to the Board of Governors that it was making offers to the IAEA and UNIDO to establish Permanent Headquarters on 'the Donaupark site' to include office buildings, conference rooms required for the performance of the organizations' functions, as well as buildings for common services. The site of 160,000 square meters on the banks of the Danube River is 7 km from the centre of Vienna An International Architects' Competition was held in 1969. The Federal Government selected the plans of Architect Johann Staber in December 1970 and commissioned him with the work. A company, the IAKW (Internationales Amtssitzund Konferenzzentrum Wien AG), was founded in May 1971 and charged with the administrative, financial, and co-ordinating functions for the entire project. The construction of the office towers began in April 1973 and the shell of these towers was completed in the spring of 1975, the completed facades having already been placed on certain towers during that time. The conference building and the common services buildings are presently under construction. Completion of the whole complex is scheduled for the latter part of 1978 and work is progressing according to schedule. The actual building costs for the whole project are estimated at 6.8 billion Austrian schillings with an additional 6.2 billion schillings financing cost, and are shared between the Federal Government (65%) and the City of Vienna (35%); in addition, the City of Vienna has provided the land. Included in the total costs are the costs for traffic lanes within and leading to the area

  14. Image fusion techniques in permanent seed implantation

    Directory of Open Access Journals (Sweden)

    Alfredo Polo

    2010-10-01

    Full Text Available Over the last twenty years major software and hardware developments in brachytherapy treatment planning, intraoperative navigation and dose delivery have been made. Image-guided brachytherapy has emerged as the ultimate conformal radiation therapy, allowing precise dose deposition on small volumes under direct image visualization. In thisprocess imaging plays a central role and novel imaging techniques are being developed (PET, MRI-MRS and power Doppler US imaging are among them, creating a new paradigm (dose-guided brachytherapy, where imaging is used to map the exact coordinates of the tumour cells, and to guide applicator insertion to the correct position. Each of these modalities has limitations providing all of the physical and geometric information required for the brachytherapy workflow.Therefore, image fusion can be used as a solution in order to take full advantage of the information from each modality in treatment planning, intraoperative navigation, dose delivery, verification and follow-up of interstitial irradiation.Image fusion, understood as the visualization of any morphological volume (i.e. US, CT, MRI together with an additional second morpholo gical volume (i.e. CT, MRI or functional dataset (functional MRI, SPECT, PET, is a well known method for treatment planning, verification and follow-up of interstitial irradiation. The term image fusion is used when multiple patient image datasets are registered and overlaid or merged to provide additional information. Fused images may be created from multiple images from the same imaging modality taken at different moments (multi-temporalapproach, or by combining information from multiple modalities. Quality means that the fused images should provide additional information to the brachythe rapy process (diagnosis and staging, treatment planning, intraoperative imaging, treatment delivery and follow-up that cannot be obtained in other ways. In this review I will focus on the role of

  15. MR angiography of eddy-current-free MR imaging system with a 3T permanent magnet

    International Nuclear Information System (INIS)

    Nishimura, H.; Watanabe, S.; Takeuchi, H.

    1991-01-01

    This paper reports that, the authors main purpose was to evaluate two-dimensional time flight MR angiography in the visualization of vascular structure by using an eddy-current-free 0.3-T permanent magnet MR imaging system. The authors have developed multisection acquisition technique for two-dimensional time-of-flight MR angiography with the use of velocity-compensated gradient echoes. MR angiograms were obtained with a ray-tracing algorithm of the new modified maximum intensity projection at various viewing angles. These angiograms are displayed on cathode-ray tubes in a high-speed cyclic mode to depict the front-rear relation of vessels for better recognition. With an eddy-current-free permanent magnet system, two-dimensional time-of-flight angiography could clearly depict intracranial vascular structure, cervical vessels, and vessels of the extremities with thin-section (2 or 3 mm) acquisition. A high flip angle (90 degrees) with a short TR enabled better differentiation between blood flow and stationary tissues. Stenosis of the carotids could be detected in accordance with digital subtraction angiography

  16. Prevalence of venous obstruction in permanent endovenous pacing in newborns and infants: follow-up study.

    Science.gov (United States)

    Stojanov, Petar; Vranes, Mile; Velimirovic, Dusan; Zivkovic, Mirjana; Kocica, Mladen J; Davidovic, Lazar; Neskovic, Voislava; Stajevic, Mila

    2005-05-01

    We examined the prevalence of venous obstruction in 12 newborns and infants with permanent endovenous ventricular pacing, clinically, and by ultrasonographic assessment of hemodynamics (spontaneity, phasicity, velocity, and turbulence of flow) and morphologic parameters (compressibility, wall thickness, and thrombus presence). All implantations of single ventricular unipolar endovenous steroid leads, were performed via cephalic vein, and pacemakers were placed in subcutaneous pocket in right prepectoral region. After the vascular surgeon has carefully examined all children for presence of venous collaterals in the chest wall, morphologic and hemodynamic parameters of the subclavian, axillary, and internal jugular veins, were assessed by linear-array color Doppler. Lead capacity (LC) was calculated for each patient. Mean age of patients at implant was 6.2 months (range 1 day-12 months), mean weight 6.5 kg (range 2.25-10 kg), and mean height 60.9 cm (range 48-78 cm). Mean LC was 1.99 (range 1.14-3.07). Total follow-up was 1023 and mean follow-up 85.2 pacing months (range 3-156). No clinical signs of venous obstruction were observed. Mild stenosis (20%) of subclavian vein was found by color Doppler in 2/12 patients. Both had adequate lead diameter for body surface. Permanent endovenous pacing is a feasible procedure, even in children of body weight less than 10 kg, with quite acceptable impact on venous system patency.

  17. Permanent vascular access survival in children on long-term chronic hemodialysis.

    Science.gov (United States)

    Briones, Liliana; Diaz Moreno, Alexia; Sierre, Sergio; Lopez, Laura; Lipsich, José; Adragna, Marta

    2010-09-01

    The aim of this study is to report a single-center experience regarding the management and outcome of permanent vascular accesses (VA) in children on chronic hemodialysis (HD). We analyzed the survival of permanent VA in 79 pediatric patients with end-stage renal disease patients on chronic HD between January 2000 and December 2008. One hundred and thirty-seven VA [89 native fistulas (AVFs) and 48 grafts (AVGs)] were created in 79 children. The creation of AVFs was significantly more frequent in children weighing >25 kg and AVGs in children weighing <25 kg (p = 0.003). The 1-year primary patency rate was 50% for AVF and 30% for AVG. The secondary patency rates at 1, 2, and 3 years for AVFs were 73, 50, and 20% and for AVGs were 64, 36, and 20%, respectively. The total number of surgical and endovascular interventions was significantly higher in AVGs (p stenosis, thrombosis and infection episodes occurred more frequently in AVG (p = 0.02). VAs had a high rate of interventions. Our study demonstrated better results of AVFs formation over AVGs, for long-term HD access in pediatrics. Surveillance and radiologic procedures are necessary for early detection and treatment of access complications in order to extend access survival.

  18. Complete subglottic tracheal stenosis managed with rigid bronchoscopy and T-tube placement

    Directory of Open Access Journals (Sweden)

    Kuruswamy Thurai Prasad

    2016-01-01

    Full Text Available Surgery is the preferred treatment modality for benign tracheal stenosis. Interventional bronchoscopy is used as a bridge to surgery or in instances when surgery is not feasible or has failed. Stenosis in the subglottic trachea is particularly a treatment challenge, in view of its proximity to the vocal cords. Herein, we describe a patient with complete tracheal stenosis in the subglottic region, which developed after prolonged intubation and mechanical ventilation. The patient developed recurrent stenosis despite multiple surgical and endoscopic procedures. We were able to manage the patient successfully with rigid bronchoscopy and Montgomery T-tube placement.

  19. Cutting-balloon angioplasty of resistant ureteral stenosis as bridge to stent insertion

    Energy Technology Data Exchange (ETDEWEB)

    Iezzi, R., E-mail: iezzir@virgilio.it [Department of Bioimaging and Radiological Sciences, Institute of Radiology, ' A. Gemelli' Hospital - Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Di Stasi, C.; Simeone, A.; Bonomo, L. [Department of Bioimaging and Radiological Sciences, Institute of Radiology, ' A. Gemelli' Hospital - Catholic University, L.go A Gemelli 8, 00168 Rome (Italy)

    2011-07-15

    Ureteral stenting is a routine, minimally invasive procedure performed for relief of benign or malignant obstruction. In case of ureteral stenosis, to allow a correct insertion of the stent, a predilatation of the ureter stenosis with a conventional balloon catheter can be necessary. In exceptional cases, it can be difficult to advance an 7-8 Fr JJ-catheter over a tight resistant ureter stenosis following unsuccessful high-pressure balloon dilatation. In the present report, we describe two cases of resistant ureter stenosis successfully dilated by a cutting-balloon following the failure of high-pressure balloon dilatation, allowing a correct and uncomplicated antegrade stent insertion.

  20. Cutting-balloon angioplasty of resistant ureteral stenosis as bridge to stent insertion

    International Nuclear Information System (INIS)

    Iezzi, R.; Di Stasi, C.; Simeone, A.; Bonomo, L.

    2011-01-01

    Ureteral stenting is a routine, minimally invasive procedure performed for relief of benign or malignant obstruction. In case of ureteral stenosis, to allow a correct insertion of the stent, a predilatation of the ureter stenosis with a conventional balloon catheter can be necessary. In exceptional cases, it can be difficult to advance an 7-8 Fr JJ-catheter over a tight resistant ureter stenosis following unsuccessful high-pressure balloon dilatation. In the present report, we describe two cases of resistant ureter stenosis successfully dilated by a cutting-balloon following the failure of high-pressure balloon dilatation, allowing a correct and uncomplicated antegrade stent insertion.

  1. Lumbosacral stenosis in Labrador retriever military working dogs - an exomic exploratory study.

    Science.gov (United States)

    Mukherjee, Meenakshi; Jones, Jeryl C; Yao, Jianbo

    2017-01-01

    Canine lumbosacral stenosis is defined as narrowing of the caudal lumbar and/or sacral vertebral canal. A risk factor for neurologic problems in many large sized breeds, lumbosacral stenosis can also cause early retirement in Labrador retriever military working dogs. Though vital for conservative management of the condition, early detection is complicated by the ambiguous nature of clinical signs of lumbosacral stenosis in stoic and high-drive Labrador retriever military working dogs. Though clinical diagnoses of lumbosacral stenosis using CT imaging are standard, they are usually not performed unless dogs present with clinical symptoms. Understanding the underlying genomic mechanisms would be beneficial in developing early detection methods for lumbosacral stenosis, which could prevent premature retirement in working dogs. The exomes of 8 young Labrador retriever military working dogs (4 affected and 4 unaffected by lumbosacral stenosis, phenotypically selected by CT image analyses from 40 dogs with no reported clinical signs of the condition) were sequenced to identify and annotate exonic variants between dogs negative and positive for lumbosacral stenosis. Two-hundred and fifty-two variants were detected to be homozygous for the wild allele and either homozygous or heterozygous for the variant allele. Seventeen non-disruptive variants were detected that could affect protein effectiveness in 7 annotated (SCN1B, RGS9BP, ASXL3, TTR, LRRC16B, PTPRO, ZBBX) and 3 predicted genes (EEF1A1, DNAJA1, ZFX). No exonic variants were detected in any of the canine orthologues for human lumbar spinal stenosis candidate genes. TTR (transthyretin) gene could be a possible candidate for lumbosacral stenosis in Labrador retrievers based on previous human studies that have reported an association between human lumbar spinal stenosis and transthyretin protein amyloidosis. Other genes identified with exonic variants in this study but with no known published association with lumbosacral

  2. The angiographic incidence of renal artery stenosis in the arterioscleritic population

    International Nuclear Information System (INIS)

    Wils, G.; Marchal, G.; Peene, P.; Baert, A.L.

    1990-01-01

    The incidence of renal artery stenosis was evaluated with intra-arterial digital subtraction anghiography in 100 consecutive patients referred for peripheral arteriopathy. Fifty-seven patients were normotensive, 43 were hypertensive. In the normotensive group, renal artery stenosis was found in ten patients (17.5%). In the hypertensive group renal artery stenosis was found in twelve patients (28%). It is concluded that the incidence of renal aretery stenosis is high in an arterioslcerotic population both in normotensive and hypertensive patients. (author). 16 refs.; 1 tab

  3. Early Manifestation of Supravalvular Aortic and Pulmonary Artery Stenosis in a Patient with Williams Syndrome

    Directory of Open Access Journals (Sweden)

    Jong Uk Lee

    2016-04-01

    Full Text Available Williams syndrome (WS is a developmental disorder characterized by vascular abnormalities such as thickening of the vascular media layer in medium- and large-sized arteries. Supravalvular aortic stenosis (SVAS and peripheral pulmonary artery stenosis (PPAS are common vascular abnormalities in WS. The natural course of SVAS and PPAS is variable, and the timing of surgery or intervention is determined according to the progression of vascular stenosis. In our patient, SVAS and PPAS showed rapid concurrent progression within two weeks after birth. We report the early manifestation of SVAS and PPAS in the neonatal period and describe the surgical treatment for stenosis relief.

  4. THE PRINCIPLE OF PERMANENCE IN A CONSUMER SOCIETY

    Directory of Open Access Journals (Sweden)

    A. N. Il’in

    2017-01-01

    Full Text Available In a consumer society dominated by the imperative that requires permanent update personal system of things (the permanence principle. The production serves not just the needs and growth needs. It focuses on production of a growing number of including the  minimum useful things, but having a prestigious status and a symbolic completeness. A comparative analysis of the companies of production and the consumer society on the basis of the dominant attitude to things. Disclosed two forms of things aging: physical deterioration and moral obsolescence. Many things advertised specially created low-quality for quick change by the user. Or the infrastructure of the fashion and advertising calls for to constantly buy new things to be always in trend, be fashionable, to emphasize their social status. The concept of modernity encompasses extremely short period of time. Today the luxury of tomorrow is becoming the norm, and novelty – archaic. There is an effect of accelerating history. Even if the needs are met, the infrastructure “discovers” new needs. Builds a causal chain: growing production and advertising production speed – creates new needs – a person consumes produce results and thus contributing to its further increase. Symbolism – not a stable characteristic of a particular product. The symbol of the fashion elite goes from one generation to the other things, none of them, not finding a permanent place of localization. Therefore, the symbolic “shelf life” of things to expire soon their physical expiration date. In terms the rapid development of technology and the emergence of new generations of products emphasizing the status is possible through the permanent acquisition of the newest gadgets. Self-presentation – a process based on the permanent use of marketable novelty. This concluded the effect of corporeal gerontophobia. Formed permanence phenomenon, which can be defined as a culture inspired by the

  5. Sequential Venoplasty for Treatment of Inferior Vena Cava Stenosis Following Liver Transplant

    Directory of Open Access Journals (Sweden)

    Ahmad Parvinian

    2014-01-01

    Full Text Available Obstruction of the inferior vena cava (IVC is a rare complication of liver transplantation with significant consequences including intractable ascites and hepatic dysfunction. Although venoplasty and stenting are effective in many cases, patients who fail first-line treatment may require surgical intervention or re-transplantation. Scheduled sequential balloon dilation, an approach frequently used to treat fibrotic, benign biliary strictures, but less commonly vascular lesions, may avert the need for such high-risk alternatives while achieving favorable clinical and angiographic response. Herein, we report the case of a 36-year-old woman with transplant-related, initially angioplasty-resistant IVC stenosis that was successfully treated with sequential balloon dilation.

  6. The road to higher permanence and biodiversity in exurban wetlands.

    Science.gov (United States)

    Urban, Mark C; Roehm, Robert

    2018-01-01

    Exurban areas are expanding throughout the world, yet their effects on local biodiversity remain poorly understood. Wetlands, in particular, face ongoing and substantial threats from exurban development. We predicted that exurbanization would reduce the diversity of wetland amphibian and invertebrate communities and that more spatially aggregated residential development would leave more undisturbed natural land, thereby promoting greater local diversity. Using structural equation models, we tested a series of predictions about the direct and indirect pathways by which exurbanization extent, spatial pattern, and wetland characteristics might affect diversity patterns in 38 wetlands recorded during a growing season. We used redundancy, indicator species, and nested community analyses to evaluate how exurbanization affected species composition. In contrast to expectations, we found higher diversity in exurban wetlands. We also found that housing aggregation did not significantly affect diversity. Exurbanization affected biodiversity indirectly by increasing roads and development, which promoted permanent wetlands with less canopy cover and more aquatic vegetation. These pond characteristics supported greater diversity. However, exurbanization was associated with fewer temporary wetlands and fewer of the species that depend on these habitats. Moreover, the best indicator species for an exurban wetland was the ram's head snail, a common disease vector in disturbed ponds. Overall, results suggest that exurbanization is homogenizing wetlands into more permanent water bodies. These more permanent, exurban ponds support higher overall animal diversity, but exclude temporary wetland specialists. Conserving the full assemblage of wetland species in expanding exurban regions throughout the world will require protecting and creating temporary wetlands.

  7. Rotating permanent magnet excitation for blood flow measurement.

    Science.gov (United States)

    Nair, Sarath S; Vinodkumar, V; Sreedevi, V; Nagesh, D S

    2015-11-01

    A compact, portable and improved blood flow measurement system for an extracorporeal circuit having a rotating permanent magnetic excitation scheme is described in this paper. The system consists of a set of permanent magnets rotating near blood or any conductive fluid to create high-intensity alternating magnetic field in it and inducing a sinusoidal varying voltage across the column of fluid. The induced voltage signal is acquired, conditioned and processed to determine its flow rate. Performance analysis shows that a sensitivity of more than 250 mV/lpm can be obtained, which is more than five times higher than conventional flow measurement systems. Choice of rotating permanent magnet instead of an electromagnetic core generates alternate magnetic field of smooth sinusoidal nature which in turn reduces switching and interference noises. These results in reduction in complex electronic circuitry required for processing the signal to a great extent and enable the flow measuring device to be much less costlier, portable and light weight. The signal remains steady even with changes in environmental conditions and has an accuracy of greater than 95%. This paper also describes the construction details of the prototype, the factors affecting sensitivity and detailed performance analysis at various operating conditions.

  8. Wind turbine integrated multipole permanent magnet generator (PMG)

    Energy Technology Data Exchange (ETDEWEB)

    Vilsboell, N.; Pinegin, A.; Goussarov, D.

    1996-01-01

    Designed permanent magnet generator (PMG - 20 kW) possesses a number of advantages: it makes possible to replace gearbox, the generator and possibly the hub of the wind turbine by combining wind rotor with external rotor of the generator; use of rare earth magnets Nd-Fe-B allows to reduce mass and dimensions of the generator; use of the PMG for wind turbines increases the reliability of the construction during the life time, comparing to the conventional design (gearbox, asynchronous generator). The test of the PMG -20 kW informs that design method, developed for calculation of multipole permanent magnet generators is correct in general and meets engineering requirements. The calculation uncertainty of the magnetic system and output characteristics does not exceed 2-3%. The test shows, that the maximum efficiency of the PGM - 20 kW with full load can be achieved as high as 90-91.5% and excels the efficiency of the traditional system `generator-gearbox` by 4-5.5%. Designing permanent magnet generator, it is recommended to take into account voltage stabilization (capacitance). Efficiency is expected to be higher, mass and production cost of the generator can be reduced by 25-30%. The frequency converter shall be used not only for control of rotational speed, but also to obtain sinusoidal capacitive current on the generator side. For PMG - 20 kW the angle between voltage and current should be within the range 0-23%. (au)

  9. Permanent magnet materials and their application

    International Nuclear Information System (INIS)

    Campbell, P.

    1994-01-01

    Permanent magnets are of great industrial importance in industrial drives, consumer products, computers, and automobiles. Since 1970, new classes of magnet materials have been developed. This book reviews the older and newer materials and is presented as a comprehensive design text for permanent magnets and their applications. After an initial chapter on the fundamentals of magnetism, the author discusses magnetic physics considerations specific to permanent magnets and describes the fabrications and characteristics of commercial materials: alnico, samarium-cobalt, ferrite, and neodymium-iron-boron. Thermal stability, magnet design procedures, magnetic field analysis methods, and measurement methods are discussed in subsequent chapters, followed by a concluding chapter reviewing commercial and industrial products that use permanent magnets. The chapter on thermal properties of magnet materials is of particular interest, bringing together information not readily found elsewhere. The review of applications is also deserving of attention, specifically the sections on motors and actuators. Although particle accelerator applications are discussed, the use of permanent magnet sextuples in modern ECR ion sources is not mentioned

  10. Cylindrical Hall Thrusters with Permanent Magnets

    International Nuclear Information System (INIS)

    Raitses, Yevgeny; Merino, Enrique; Fisch, Nathaniel J.

    2010-01-01

    The use of permanent magnets instead of electromagnet coils for low power Hall thrusters can offer a significant reduction of both the total electric power consumption and the thruster mass. Two permanent magnet versions of the miniaturized cylindrical Hall thruster (CHT) of different overall dimensions were operated in the power range of 50W-300 W. The discharge and plasma plume measurements revealed that the CHT thrusters with permanent magnets and electromagnet coils operate rather differently. In particular, the angular ion current density distribution from the permanent magnet thrusters has an unusual halo shape, with a majority of high energy ions flowing at large angles with respect to the thruster centerline. Differences in the magnetic field topology outside the thruster channel and in the vicinity of the channel exit are likely responsible for the differences in the plume characteristics measured for the CHTs with electromagnets and permanent magnets. It is shown that the presence of the reversing-direction or cusp-type magnetic field configuration inside the thruster channel without a strong axial magnetic field outside the thruster channel does not lead to the halo plasma plume from the CHT.

  11. 31 CFR 515.335 - Permanent resident alien.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Permanent resident alien. 515.335... Definitions § 515.335 Permanent resident alien. As used in § 515.208, the term permanent resident alien means an alien lawfully admitted for permanent residence into the United States. [61 FR 37386, July 18...

  12. 13 CFR 120.900 - Sources of permanent financing.

    Science.gov (United States)

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Sources of permanent financing... Development Company Loan Program (504) Permanent Financing § 120.900 Sources of permanent financing. Permanent financing for each Project must come from three sources: the Borrower's contribution, Third-Party Loans, and...

  13. Static devices with new permanent magnets

    International Nuclear Information System (INIS)

    Chavanne, J.; Laforest, J.; Pauthenet, R.

    1987-01-01

    The high remanence and coercivity of the new permanent magnet materials are of special interest in the static applications. High ordering temperature and are uniaxial anisotropy at the origin of their good permanent magnet properties are obtained in rare earth-transition metal compounds. Binary SmCo/sub 5/ and Sm/sub 2/Co/sub 17/ and ternary Nd/sub 2/Fe/sub 14/B compounds are the basis materials of the best permanent magnets. new concepts of calculations of static devices with these magnets can be applied: the magnetization can be considered as ridig, the density of the surface Amperian current is constant, the relative permeability is approximately 1 and the induction calculations are linear. Examples of hexapoles with Sm-Co and NdFeB magnets are described and the performances are compared. The problems of temperature behavior and corrosion resistance are underlined

  14. Radiation exposure after permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Cattani, Federica; Vavassori, Andrea; Polo, Alfredo; Rondi, Elena; Cambria, Raffaella; Orecchia, Roberto; Tosi, Giampiero

    2006-01-01

    Background and purpose: Limited information is available on the true radiation exposure and associated risks for the relatives of the patients submitted to prostate brachytherapy with permanent implant of radioactive sources and for any other people coming into contact with them. In order to provide appropriate information, we analyzed the radiation exposure data from 216 prostate cancer patients who underwent 125 I or 103 Pd implants at the European Institute of Oncology of Milan, Italy. Patients and methods: Between October 1999 and October 2004, 216 patients with low risk prostate carcinoma were treated with 125 I (200 patients) or 103 Pd (16 patients) permanent seed implantation. One day after the procedure, radiation exposure measurements around the patients were performed using an ionization chamber survey meter (Victoreen RPO-50) calibrated in dose rate at an accredited calibration center (calibration Centre SIT 104). Results: The mean dose rate at the posterior skin surface (gluteal region) following 125 I implants was 41.3 μSv/h (range: 6.2-99.4 μSv/h) and following 103 Pd implants was 18.9 μSv/h (range 5.0-37.3 μSv/h). The dose rate at 50 cm from the skin decreased to the mean value of 6.4 μSv/h for the 125 I implants and to the mean value of 1.7 μSv/h for the 103 Pd implants. Total times required to reach the annual dose limit (1 mSv/year) recommended for the general population by the European Directive 96/29/Euratom and by the Italian law (Decreto Legislativo 241/2000) at a distance of 50 cm from the posterior skin surface of the implanted patient would be 7.7 and 21.6 days for 125 I and for 103 Pd. Good correlation between the measured dose rates and both the total implanted activity and the distance between the most posteriorly implanted seed and the skin surface of the patients was found. Conclusions: Our data show that the dose rates at 50 cm away from the prostate brachytherapy patients are very low and that the doses possibly absorbed by the

  15. Analysis of a spherical permanent magnet actuator

    International Nuclear Information System (INIS)

    Wang, J.; Jewell, G.W.; Howe, D.

    1997-01-01

    This paper describes a new form of actuator with a spherical permanent magnet rotor and a simple winding arrangement, which is capable of a high specific torque by utilizing a rare-earth permanent magnet. The magnetic-field distribution is established using an analytical technique formulated in spherical coordinates, and the results are validated by finite element analysis. The analytical field solution allows the prediction of the actuator torque and back emf in closed forms. In turn, these facilitate the characterization of the actuator and provide a firm basis for design optimization, system dynamic modeling, and closed-loop control law development. copyright 1997 American Institute of Physics

  16. Treatment of ectopic first permanent molar teeth.

    LENUS (Irish Health Repository)

    Hennessy, Joe

    2012-11-01

    Ectopic eruption of the first permanent molar is a relatively common occurence in the developing dentition. A range of treatment options are available to the clinician provided that diagnosis is made early. Non-treatment can result in premature exfoliation of the second primary molar, space loss and impaction of the second premolar. This paper will describe the management of ectopic first permanent molars, using clinical examples to illustrate the available treatment options. CLINICAL RELEVANCE: This paper is relevant to every general dental practitioner who treats patients in mixed dentition.

  17. Permanent isolation surface barrier: Functional performance

    International Nuclear Information System (INIS)

    Wing, N.R.

    1993-10-01

    This document presents the functional performance parameters for permanent isolation surface barriers. Permanent isolation surface barriers have been proposed for use at the Hanford Site (and elsewhere) to isolate and dispose of certain types of waste in place. Much of the waste that would be disposed of using in-place isolation techniques is located in subsurface structures, such as solid waste burial grounds, tanks, vaults, and cribs. Unless protected in some way, the wastes could be transported to the accessible environment via transport pathways, such as water infiltration, biointrusion, wind and water erosion, human interference, and/or gaseous release

  18. Magnetic guns with cylindrical permanent magnets

    DEFF Research Database (Denmark)

    Vokoun, David; Beleggia, Marco; Heller, Luděk

    2012-01-01

    The motion of a cylindrical permanent magnet (projectile) inside a tubular permanent magnet, with both magnets magnetized axially, illustrates nicely the physical principles behind the operation of magnetic guns. The force acting upon the projectile is expressed semi-analytically as derivative...... of the magnetostatic interaction energy. For comparison, the forces involved are also calculated numerically using finite elements methods. Based on the conservation of the magnetostatic and kinetic energies, the exit and asymptotic velocities are determined. The derived formulas can be used to optimize the generated...... forces and motion of the inner cylindrical magnet....

  19. Treatment of ectopic first permanent molar teeth.

    Science.gov (United States)

    Hennessy, Joe; Al-Awadhi, E A; Dwyer, Lian O; Leith, Rona

    2012-11-01

    Ectopic eruption of the first permanent molar is a relatively common occurence in the developing dentition. A range of treatment options are available to the clinician provided that diagnosis is made early. Non-treatment can result in premature exfoliation of the second primary molar, space loss and impaction of the second premolar. This paper will describe the management of ectopic first permanent molars, using clinical examples to illustrate the available treatment options. This paper is relevant to every general dental practitioner who treats patients in mixed dentition.

  20. Pirm wastes: permanent isolation in rock-forming minerals

    International Nuclear Information System (INIS)

    Smyth, J.R.; Vidale, R.J.; Charles, R.W.

    1977-01-01

    The most practical system for permanent isolation of radioactive wastes in granitic and pelitic environments may be one which specifically tailors the waste form to the environment. This is true because if recrystallization of the waste form takes place within the half-lives of the hazardous radionuclides, it is likely to be the rate-controlling step for release of these nuclides to the ground-water system. The object of the proposed waste-form research at Los Alamos Scintific Laboratory (LASL) is to define a phase assemblage which will minimize chemical reaction with natural fluids in a granitic or pelitic environment. All natural granites contain trace amounts of all fission product elements (except Tc) and many contain minor amounts of these elements as major components of certain accessory phases. Observation of the geochemistry of fission-product elements has led to the identification of the natural minerals as target phases for research. A proposal is made to experimentally determine the amounts of fission product elements which can stably be incorporated into the phases listed below and to determine the leachability of the assemblage this produced using fluids typical of the proposed environments at the Nevada Test Site. This approach to waste isolation satisfies the following requirements: (1) It minimizes chemical reaction with the environment (i.e., recrystallization) which is likely to be the rate-controlling step for release of radionuclides to groundwater; (2) Waste loading (hence temperature) can be easily varied by dilution with material mined from the disposal site; (3) No physical container is required; (4) No maintenance is required (permanent); (5) The environment acts as a containment buffer. It is proposed that such wastes be termed PIRM wastes, for Permanent Isolation in Rock-forming Minerals

  1. Advanced esophageal cancer and esophageal stenosis endoscopic treatment

    International Nuclear Information System (INIS)

    Piazze, A. E mail: apiazze@hc.edu.uy

    2005-01-01

    Advanced esophageal cancer (AEC) is diagnosed during those stages in which surgery is possible, it is palliative for disphagia, with high morbimortality.In inoperable or irresectable cases, resorting to alternative treatment such as radiotherapy or endoscopy may palliate dsphagia.Endoscopically it is possible to place a transtumoral nasogastric catheter (NGC) for preoperative nutrition or branchial therapy (intratumoral iridium).It is possible to dilate the tumor and place and indwelling plastic or auto expandable prosthesis or to inject absolute intratumoral alcohol.There is and evaluation of results and morbimortality of personal case material through the retrospective study of 54 patients in whom 120 procedures such as those referred to above were carried out.The series includes 41 men and 13 women (3-1), 79.5% of which were of ages between 61 and 90.Optic fiber endoscopes or video endoscopes, coaxial dilators, hydro-pneumatic balloons, metallic guides and non industrial and autoexpandable plastic prosthesis were used; 34.1% of procedures were performed under used; 34.1% of procedures were performed under radioscopy.Eleven patient (8 for nutritional purposes and 3 for brachiotherapy)form part of Groups 1 and 2 of NGC.Group 3 consist of:dilations of radicular stenosis with or without neopasic recurrence, or neoplasic infiltration of esophagus, 6 patient; Group 4: 14 patients for the purpose of dilation of esophageal neoplasm; Group 5:prosthesis, 12 patients; Group 6: 11 patients with anastomotic stenosis.In patients in Group 1-2-3 solution was achieved.In Group 3 there was 1 perforation.In Group 4, out of 14 patient 13 were dilated.In Group 5 it proved impossible to place prosthesis in 2 patient, (3.7%).The conclusion arrived at is that various endoscopic techniques may palliate disphagia in patient with AEC, collaborate with preoperative nutrition through enteral path, with brachioterapy or by treating post surgical stenosis, with low mortality

  2. Stent placement for tracheal stenosis in patients with esophageal cancer

    International Nuclear Information System (INIS)

    Takagi, Keigo; Hata, Yoshinobu; Sasamoto, Shuichi; Takahashi, Shoji; Sato, Fumitomo; Tamaki, Kazuyoshi; Goto, Hidenori; Yuasa, Rena

    2011-01-01

    Tracheal invasion including tracheal bifurcation due to esophageal cancer can sometimes cause serious complications of the airway, but such cases sometimes improve quickly following chemoradiation treatment. The absolute indications for stent replacement in the airway for this disorder and the optimal choice of stent are herein discussed. Between 1992 and 2010, 28 patients with airway stenosis, including 7 patients with esophago-tracheal fistula, were treated by placement of various stents; namely, 12 patients received Dumon stents, 3 patients had Dynamic stents, 10 patients were given Ultraflex stents, while 3 other patients were treated without the use of stents. Severe dyspnea in the supine position was observed, which mainly originated from invasion to the membranous portion of the trachea. Airway patency was maintained after stent replacement, although the median survival time of such cases was only 4 months. Three patients with severe dyspnea who could lie in a supine position recovered after undergoing chemoradiation treatment without stent replacement. No cases of stent removal were observed after chemoradiation treatment. Chemoradiation treatment for esophageal cancer was found to be effective for the management of airway disturbances, and thus the absolute indications for stent replacement are restricted to patients who cannot lie in a supine position due to severe impairment of ventilation during radiation therapy, as well as patients presenting with tracheobroncho-esophageal fistula. Concerning stent selection, a metal stent should be the first choice for tracheal stenosis due to its ease of insertion, because there is no substantial difference between silicone and metal stents regarding the treatment of tracheal stenosis. However, it is important to note that a silicone Y stent is useful for the treatment of tracheal bifurcation. (author)

  3. Connectivity features for identifying cognitive impairment in presymptomatic carotid stenosis.

    Directory of Open Access Journals (Sweden)

    Chun-Jen Lin

    Full Text Available Severe asymptomatic stenosis of the internal carotid artery (ICA leads to increased incidence of mild cognitive impairment (MCI likely through silent embolic infarcts and/or chronic hypoperfusion, but the brain dysfunction is poorly understood and difficult to diagnose. Thirty cognitively intact subjects with asymptomatic, severe (≥ 70%, unilateral stenosis of the ICA were compared with 30 healthy controls, matched for age, sex, cardiovascular risk factors and education level, on a battery of neuropsychiatric tests, voxel-based morphometry of magnetic resonance imaging (MRI, diffusion tensor imaging and brain-wise, seed-based analysis of resting-state functional MRI. Multivariate regression models and multivariate pattern classification (support vector machines were computed to assess the relationship between connectivity measures and neurocognitive performance. The patients had worse dizziness scores and poorer verbal memory, executive function and complex visuo-spatial performance than controls. Twelve out of the 30 patients (40% were considered to have MCI. Nonetheless, the leukoaraiosis Sheltens scores, hippocampal and brain volumes were not different between groups. Their whole-brain mean fractional anisotropy (FA was significantly reduced and regional functional connectivity (Fc was significantly impaired in the dorsal attention network (DAN, frontoparietal network, sensorimotor network and default mode network. In particular, the Fc strength at the insula of the DAN and the mean FA were linearly related with attention performance and dizziness severity, respectively. The multivariate pattern classification gave over 90% predictive accuracy of individuals with MCI or severe dizziness. Cognitive decline in stroke-free individuals with severe carotid stenosis may arise from nonselective widespread disconnections of long-range, predominantly interhemispheric non-hippocampal pathways. Connectivity measures may serve as both predictors for

  4. Natural History of Moderate Coronary Artery Stenosis After Surgical Revascularization.

    Science.gov (United States)

    Raza, Sajjad; Blackstone, Eugene H; Houghtaling, Penny L; Olivares, Gabriel; Ravichandren, Kirthi; Koprivanac, Marijan; Bakaeen, Faisal G; Sabik, Joseph F

    2018-03-01

    It remains controversial whether grafting moderately stenosed coronary arteries (MSCAs) influences native-vessel disease progression and whether grafting may protect against late myocardial ischemia. From 1972 to 2011, 55,567 patients underwent primary isolated coronary artery bypass grafting (CABG); 1,902 had a single coronary artery with angiographically moderate (50% to 69%) stenosis and ≥1 postoperative angiogram. Disease progression was studied in 489 nongrafted, 371 internal thoracic artery (ITA)-grafted, and 957 saphenous vein (SV)-grafted MSCAs, as well as patency of 376 ITA and 1,016 SV grafts to these MSCAs. At 1, 5, 10, and 15 years, native-vessel disease progressed from moderate to severe stenosis/occlusion in 32%, 52%, 66%, and 72% of nongrafted MSCAs; 55%, 73%, 84%, and 87% of ITA-grafted MSCAs; and 67%, 82%, 90%, and 92% of SV-grafted MSCAs. After adjusting for patient characteristics, MSCA disease progressed 3.6 times faster with ITA and 10 times faster with SV grafting compared with nongrafting. At these same time points, occlusion of ITA grafts to MSCAs was 8%, 9%, 11%, and 15% and for SV grafts, 13%, 32%, 46%, and 56%; protection from myocardial ischemia by ITA-grafted versus nongrafted MSCAs was 29%, 47%, 59%, and 61%. Most MSCAs progress to severe stenosis or occlusion in the long term. Progression is faster in grafted than nongrafted MSCAs, more so with SV than ITA grafts. However, ITA grafts to such arteries have excellent patency, providing long-term protection from myocardial ischemia. Therefore, ITA grafting of MSCAs should be considered. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Evaluating the utility of serological testing in laryngotracheal stenosis.

    Science.gov (United States)

    Hall, S Ryan; Allen, Clint T; Merati, Albert L; Mayerhoff, Ross M

    2017-06-01

    Whereas mechanical (traumatic) causes of laryngotracheal stenosis (LTS) are identified based on history, autoimmune laryngotracheal stenosis (aLTS) and idiopathic laryngotracheal stenosis (iLTS) are often more difficult to differentiate. The objective of this study was to evaluate serologic testing in a large cohort of nonmechanical LTS patients to determine which tests, if any, lead clinicians to the etiology of the LTS. Retrospective chart review. This study reviewed nonmechanical LTS patients seen at a tertiary medical center from 2007 to 2014. Data were obtained on patient demographics, associated preexisting autoimmune conditions, comorbidities, intubation history, and serologic testing. Ninety-two records were reviewed. Twenty-three (25%) patients were found to have autoimmune disease; 69 (75%) met criteria for iLTS. A history of cigarette smoking was more significant in the aLTS group than the iLTS group (P testing was equivocal between the two cohorts. Differentiating iLTS from aLTS has proven difficult. The lack of information about the two entities has resulted in variability in the diagnostic workup to distinguish them. This study's finding of a more significant smoking history in the aLTS group correlates with the literature, which suggests an inflammatory effect of smoking cigarettes and an association with autoimmune disease. The only significant cohort of patients in this study found to have positive serological testing correlated with a diagnosable condition responsible for LTS was GPA patients with positive ANCA. 4. Laryngoscope, 127:1408-1412, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  6. Impact of Hypertriglyceridemia on Carotid Stenosis Progression under Normal Low-Density Lipoprotein Cholesterol Levels.

    Science.gov (United States)

    Kitagami, Masayuki; Yasuda, Ryuta; Toma, Naoki; Shiba, Masato; Nampei, Mai; Yamamoto, Yoko; Nakatsuka, Yoshinari; Sakaida, Hiroshi; Suzuki, Hidenori

    2017-08-01

    Dyslipidemia is a well-known risk factor for carotid stenosis progression, but triglycerides have attracted little attention. The aim of this study was to assess if serum triglycerides affect progression of carotid stenosis in patients with well-controlled low-density lipoprotein cholesterol (LDL-C) levels. This is a retrospective study in a single hospital consisting of 71 Japanese patients with internal carotid artery stenosis greater than or equal to 50% and normal serum LDL-C levels who underwent angiographic examination with or without the resultant carotid artery stenting or endarterectomy from 2007 to 2011, and were subsequently followed up for 4 years. Clinical factors including fasting serum triglyceride values were compared between the progression (≥10% increase in degree of carotid stenosis on ultrasonography) and the nonprogression groups. During 4 years, 15 patients (21.1%) had carotid stenosis progression on either side. Cox regression analysis demonstrated that symptomatic cases (hazard ratio [HR], 4.327; P = .019), coexisting intracranial arteriosclerotic stenosis (HR, 5.341; P = .005), and hypertriglyceridemia (HR, 6.228; P = .011) were associated with subsequent progression of carotid stenosis. Kaplan-Meier plots demonstrated that the progression-free survival rate was significantly higher in patients without hypertriglyceridemia and intracranial arteriosclerotic stenosis at baseline. Among patients with moderate to severe carotid stenosis and well-controlled LDL-C, hypertriglyceridemia was an important risk factor for progression of carotid stenosis irrespective of surgical treatments. It would be worthwhile to test if triglyceride-lowering medications suppress carotid stenosis progression. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  7. Clinical, morphologic, and morphometric features of cranial thoracic spinal stenosis in large and giant breed dogs.

    Science.gov (United States)

    Johnson, Philippa; De Risio, Luisa; Sparkes, Andrew; McConnell, Fraser; Holloway, Andrew

    2012-01-01

    The clinical, morphologic, and morphometric features of cranial thoracic spinal stenosis were investigated in large and giant breed dogs. Seventy-nine magnetic resonance imaging studies of the cranial thoracic spine were assessed. Twenty-six were retrieved retrospectively and 53 were acquired prospectively using the same inclusion criteria. Images were evaluated using a modified compression scale as: no osseous stenosis (grade 0), osseous stenosis without spinal cord compression (grade 1), and osseous stenosis with spinal cord compression (grade 2). Morphometric analysis was performed and compared to the subjective grading system. Grades 1 and 2 cranial thoracic spinal stenosis were identified on 24 imaging studies in 23 dogs. Sixteen of 23 dogs had a conformation typified by Molosser breeds and 21/23 were male. The most common sites of stenosis were T2-3 and T3-4. The articular process joints were enlarged with abnormal oblique orientation. Stenosis was dorsolateral, lateralized, or dorsoventral. Concurrent osseous cervical spondylomyelopathy was recognized in six dogs and other neurologic disease in five dogs. Cranial thoracic spinal stenosis was the only finding in 12 dogs. In 9 of these 12 dogs (all grade 2) neurolocalization was to the T3-L3 spinal segment. The median age of these dogs was 9.5 months. In the remaining three dogs neurologic signs were not present. Stenosis ratios were of limited benefit in detecting stenotic sites. Grade 2 cranial thoracic spinal stenosis causing direct spinal cord compression may lead to neurologic signs, however milder stenosis (grade 1) is likely to be subclinical or incidental. © 2012 Veterinary Radiology & Ultrasound.

  8. Initial non-opioid based anesthesia in a parturient having severe aortic stenosis undergoing cesarean section with aortic valve replacement

    Directory of Open Access Journals (Sweden)

    Subrata Podder

    2015-01-01

    Full Text Available Pregnancy in presence of severe aortic stenosis (AS causes worsening of symptoms needing further intervention. In the advanced stages of pregnancy, some patients may even require aortic valve replacement (AVR and cesarean delivery in the same sitting. Opioid based general anesthesia for combined lower segment cesarean section (LSCS with AVR has been described. However, the use of opioid may lead to fetal morbidity and need of respiratory support for the baby. We describe successful anesthetic management for LSCS with AVR in a >33 week gravida with severe AS and congestive heart failure. We avoided opioids till delivery of the baby AVR; the delivered neonate showed a normal APGAR score.

  9. Automatic flow analysis of digital subtraction angiography using independent component analysis in patients with carotid stenosis.

    Directory of Open Access Journals (Sweden)

    Han-Jui Lee

    Full Text Available Current time-density curve analysis of digital subtraction angiography (DSA provides intravascular flow information but requires manual vasculature selection. We developed an angiographic marker that represents cerebral perfusion by using automatic independent component analysis.We retrospectively analyzed the data of 44 patients with unilateral carotid stenosis higher than 70% according to North American Symptomatic Carotid Endarterectomy Trial criteria. For all patients, magnetic resonance perfusion (MRP was performed one day before DSA. Fixed contrast injection protocols and DSA acquisition parameters were used before stenting. The cerebral circulation time (CCT was defined as the difference in the time to peak between the parietal vein and cavernous internal carotid artery in a lateral angiogram. Both anterior-posterior and lateral DSA views were processed using independent component analysis, and the capillary angiogram was extracted automatically. The full width at half maximum of the time-density curve in the capillary phase in the anterior-posterior and lateral DSA views was defined as the angiographic mean transient time (aMTT; i.e., aMTTAP and aMTTLat. The correlations between the degree of stenosis, CCT, aMTTAP and aMTTLat, and MRP parameters were evaluated.The degree of stenosis showed no correlation with CCT, aMTTAP, aMTTLat, or any MRP parameter. CCT showed a strong correlation with aMTTAP (r = 0.67 and aMTTLat (r = 0.72. Among the MRP parameters, CCT showed only a moderate correlation with MTT (r = 0.67 and Tmax (r = 0.40. aMTTAP showed a moderate correlation with Tmax (r = 0.42 and a strong correlation with MTT (r = 0.77. aMTTLat also showed similar correlations with Tmax (r = 0.59 and MTT (r = 0.73.Apart from vascular anatomy, aMTT estimates brain parenchyma hemodynamics from DSA and is concordant with MRP. This process is completely automatic and provides immediate measurement of quantitative peritherapeutic brain parenchyma

  10. Exercise-induced changes in left ventricular global longitudinal strain in asymptomatic severe aortic stenosis.

    Science.gov (United States)

    Lech, Agnieszka K; Dobrowolski, Piotr P; Klisiewicz, Anna; Hoffman, Piotr

    2017-01-01

    The management of patients with asymptomatic severe aortic stenosis (ASAS) is still under discussion. Therefore, it is advisable to search for the parameters of early damage to left ventricular (LV) function. The aim of the study was to assess exercise-induced changes in LV global longitudinal strain (GLS) in ASAS. The ASAS group consisted of 50 patients (26 women and 24 men, aged 38.4 ± 18.1 years) meeting the echocardiographic criteria of severe aortic stenosis (AVA 4 m/s, mean aortic gradient > 40 mm Hg), with normal LV ejection fraction (LVEF ≥ 55%) and sinus rhythm on electrocardiogram, and without significant concomitant valvular heart diseases. The control group consisted of 21 people matched for age and sex. Echocardiographic examinations and echocardiographic stress tests with the assessment of GLS using the speckle tracking imaging were performed. The ASAS group was characterised by statistically significantly higher LV mass index (LVMI) and higher LVEF. GLS values at rest in both groups were within normal limits but were significantly higher in the control group (-18.9 ± 2.4% vs. -20.7 ± 1.7%, p = 0.006). An increase in GLS at peak exercise in both groups was observed, lower in the ASAS group (the difference was not statistically significant: -0.8 ± 3.0% vs. -2.2 ± 3.1%, p = 0.086). Changes in GLS during exercise (ΔGLS) did not correlate with the parameters of the severity of aortic stenosis. In the multivariate model, LVMI proved to be a factor associated with GLS at rest and during exercise. In patients with ASAS, GLS is a non-invasive marker of an early stage of LV myocardial damage associated with myocardial hypertrophy. An increase in GLS during exercise in the ASAS group, smaller than in the control group, indicates a preserved functional reserve of the LV myocardium but smaller than in healthy individuals. The assessment of the clinical usefulness of exercise-induced changes in GLS requires further research.

  11. Postural stability disorders in rural patients with lumbar spinal stenosis

    Directory of Open Access Journals (Sweden)

    Aleksandra Truszczyńska

    2014-03-01

    Full Text Available Introduction. Hard work in farming may lead to lumbar spinal stenosis, and consequently, to pain. The pain and neurological disorders may lead to disability and postural disorders. Objective. The aim of the presented study was to analyse postural stability and its correlation with functional disability of patients with lumbar spinal stenosis living in rural areas. Materials and methods. The study population consisted of 30 rural patients with lumbar spinal stenosis; mean age: 51.40 (±12.92; mean BMI: 28.60 (±3.77. The control group consisted of 30 rural inhabitants without spinal disorders. Postural stability was tested on the Biodex Balance System. The patients were also evaluated according to the ODI, the Rolland- Morris disability questionnaire, and VAS. Results. The mean results of the patients studied were as follows: 49.37 (±17.39 according to ODI, 15 (±6.19 according to the Rolland-Morris disability scale, and pain intensity of 7 (±1.93 according to the VAS. The following statistically significant differences were found: the mean balance index result was 1.8 (±1.88 and 0.64 (±0.41 in the control group. The mean centre of mass deviation in the A/P plane was 1.39 (±1.88 and 0.46 (±0.41 in the control group. The mean centre of mass deviation in the M/L plane was 0.8 (±0.51 and 0.32 (±0.22 in the control group. The balance in the studied population correlated significantly with the Rolland-Morris disability questionnaire and the VAS. Conclusions: 1 Serious disability was found in rural patients with spinal stenosis. There was a statistically significant correlation between the disability and postural stability disorders. 2 Most of the patients (84% were overweight. 3 Postural stability disorders were statistically significant for both the stability index and the A/P plane deviation.

  12. Congenital esophageal stenosis in 3 children: A case series

    Directory of Open Access Journals (Sweden)

    Mackenzie C. Lees

    2017-08-01

    Full Text Available Congenital esophageal stenosis (CES is rare condition found in 1 per 25,000 to 50,000 live births. It is characterized by intrinsic narrowing of the esophagus secondary to congenital malformation of the esophageal wall architecture. Diagnosis is often difficult to definitively establish as the symptoms are often initially attributed to esophageal strictures secondary to reflux, or occur within the context of a tracheo-esophageal fistula (TEF in the newborn. Endoscopic dilation and surgical repair are the mainstays of treatment. We report a series of three cases seen recently at our institution, the University of Alberta/Stollery Children's Hospital.

  13. Imaging and management of atherosclerotic renal artery stenosis

    International Nuclear Information System (INIS)

    Sarkodieh, J.E.; Walden, S.H.; Low, D.

    2013-01-01

    Renal artery stenosis (RAS) causes chronic, progressive ischaemic nephropathy and is the most common cause of secondary hypertension. Radiology plays a large part in the diagnosis, with a variety of imaging techniques available. Each has relative advantages and disadvantages depending on each unique clinical setting. We discuss and illustrate the range of diagnostic methods and interventional techniques for diagnosis and management of RAS and review the current evidence base for endovascular therapy compared with optimal medical management. Knowledge of the relative merits of the various forms of imaging and treatment will guide decision making in the multidisciplinary setting

  14. Endovascular stent-support angioplasty for cerebral venous sinus stenosis

    Directory of Open Access Journals (Sweden)

    Xin-feng LI

    2011-06-01

    Full Text Available Objective To investigate the pathophysiological features of cerebral venous sinus stenosis,and the modus and therapeutic effect of stent-support angioplasty.Methods The clinical data of 36 patients with cerebral venous sinus stenosis,admitted to Neurosurgical Department of General Hospital of PLA from Dec.2001 to Jun.2010,were retrospectively analyzed.Of the 36 cases,10 were males and 26 females,aged from 14 to 57 years with a mean of 37.8 years,and the disease course ranged from 4 days to 9 years.The main clinical manifestations included headache,vomiting,optical visual blurring,and limb weakness with anesthesia in some patients.The diagnosis of all patients was confirmed by digital subtraction angiography,and the results showed that the local stenosis located in right transverse-sigmoid sinus in 21 cases,left transverse-sigmoid sinus in 12 cases,and on both sides in 3 cases.All patients received thrombolytic therapy via carotid artery or a microcatheter inserted in the venous sinus,followed by stent angioplasty of venous sinus.Meanwhile,general anticoagulant and antiplatelet therapy were essential.Results All the 36 patients were successively treated with balloon dilatation and stent angioplasty of venous sinus with exception of 3 cases,who failed because of the circuitous jugular foramen preventing the insertion of the stent.The successful rate was 91.7%.The cerebrospinal fluid pressure of the patients was lowered from 374.7±82.9mmH2O before operation to 230.3±48.1mmH2O after operation.Thirty-three patients were followed-up for 1 month to 8 years by brain angiography and examinations in the outpatient clinic.Among them 32 showed persistent relief of clinical symptoms.The remaining patient presented severe headache and optical visual blurring 1 month after stent implantation,however the symptoms were alleviated obviously after thrombolytic therapy via the carotid artery with adequate anticoagulation.Conclusions Stent angioplasty of venous

  15. Indications and interventional options for non-resectable tracheal stenosis

    Science.gov (United States)

    Bacon, Jenny Louise; Patterson, Caroline Marie

    2014-01-01

    Non-specific presentation and normal examination findings in early disease often result in tracheal obstruction being overlooked as a diagnosis until patients present acutely. Once diagnosed, surgical options should be considered, but often patient co-morbidity necessitates other interventional options. Non-resectable tracheal stenosis can be successfully managed by interventional bronchoscopy, with therapeutic options including airway dilatation, local tissue destruction and airway stenting. There are common aspects to the management of tracheal obstruction, tracheomalacia and tracheal fistulae. This paper reviews the pathogenesis, presentation, investigation and management of tracheal disease, with a focus on tracheal obstruction and the role of endotracheal intervention in management. PMID:24624290

  16. Collateral veins in left renal vein stenosis demonstrated via CT

    Energy Technology Data Exchange (ETDEWEB)

    Lien, H.H.; Lund, G.; Talle, K.

    1983-02-01

    Twelve patients with left renal vein stenosis from tumor compression were studied with CT. All had distended collateral veins in the perirenal space which either formed a radiating or a cobweb pattern or appeared as marked longitudinal veins. Inferior phrenic vein branches were seen in seven patients and were considerably enlarged in two. Other major veins possibly taking part in collateral circulation could not be recognized due to obliteration of fat planes. The renal fascia was thickened in eleven patients, probably due to edema. A close study of the perirenal space with CT may give valuable information about collateral development.

  17. Collateral veins in left renal vein stenosis demonstrated via CT

    International Nuclear Information System (INIS)

    Lien, H.H.; Lund, G.; Talle, K.

    1983-01-01

    Twelve patients with left renal vein stenosis from tumor compression were studied with CT. All had distended collateral veins in the perirenal space which either formed a radiating or a cobweb pattern or appeared as marked longitudinal veins. Inferior phrenic vein branches were seen in seven patients and were considerably enlarged in two. Other major veins possibly taking part in collateral circulation could not be recognized due to obliteration of fat planes. The renal fascia was thickened in eleven patients, probably due to edema. A close study of the perirenal space with CT may give valuable information about collateral development. (orig.)

  18. Permanent magnet steerers for canted undulators at the ESRF

    Energy Technology Data Exchange (ETDEWEB)

    Le Bec, G., E-mail: lebec@esrf.fr [ESRF, 6 r. J. Horowitz, BP 220, 38043 Grenoble Cedex 9 (France); Chavanne, J. [ESRF, 6 r. J. Horowitz, BP 220, 38043 Grenoble Cedex 9 (France)

    2012-02-01

    A number of canted undulators will be installed at the ESRF. Permanent Magnet Steerers will be used for providing canting angles up to 5.4 mrad. These steerers have been optimized in view of the limited space available and the required field quality. The magnetic interaction between the steerers and the undulators may lead to additional optical phase errors: auxiliary poles have been added to obtain a fast decrease of the fringe field. The transverse homogeneity of the magnetic field integral is another strong design constraint. Good homogeneity was reached by optimizing the profiles of the iron poles. Eight steerers have been constructed and magnetic measurements have been performed.

  19. Cigarette smoking and cardio-renal events in patients with atherosclerotic renal artery stenosis.

    Directory of Open Access Journals (Sweden)

    Christopher A Drummond

    Full Text Available Cigarette smoking causes cardiovascular disease and is associated with poor kidney function in individuals with diabetes mellitus and primary kidney diseases. However, the association of smoking on patients with atherosclerotic renal artery stenosis has not been studied. The current study utilized data from the Cardiovascular Outcomes in Renal Atherosclerotic Lesions (CORAL, NCT00081731 clinical trial to evaluate the effects of smoking on the risk of cardio-renal events and kidney function in this population. Baseline data showed that smokers (n = 277 out of 931 were significantly younger at enrollment than non-smokers (63.3±9.1 years vs 72.4±7.8 years; p<0.001. In addition, patients who smoke were also more likely to have bilateral renal artery stenoses and peripheral vascular disease (PVD. Longitudinal analysis showed that smokers experienced composite endpoint events (defined as first occurrence of: stroke; cardiovascular or renal death; myocardial infarction; hospitalization for congestive heart failure; permanent renal replacement; and progressive renal insufficiency defined as 30% reduction of GFR from baseline sustained for ≥ 60 days at a substantially younger age compared to non-smokers (67.1±9.0 versus 76.1±7.9, p<0.001. Using linear regression and generalized linear modeling analysis controlled by age, sex, and ethnicity, smokers had significantly higher cystatin C levels (1.3±0.7 vs 1.2±0.9, p<0.01 whereas creatinine and estimated glomerular filtration rate (eGFR were not different from non-smokers. From these data we conclude that smoking has a significant association with deleterious cardio-renal outcomes in patients with renovascular hypertension.

  20. Efficacy of duplex ultrasound surveillance after infrainguinal vein bypass may be enhanced by identification of characteristics predictive of graft stenosis development.

    Science.gov (United States)

    Tinder, Chelsey N; Chavanpun, Joe P; Bandyk, Dennis F; Armstrong, Paul A; Back, Martin R; Johnson, Brad L; Shames, Murray L

    2008-09-01

    (15%) limbs, the bypass graft failed and 20 (6%) limbs required amputation. The efficacy of duplex surveillance after infrainguinal vein bypass may be enhanced by modifying testing protocols, eg, rigorous surveillance for "higher risk" bypasses, based on the initial duplex scan results and other characteristics (warfarin therapy, non- single segment saphenous vein conduit, redo bypass) predictive for stenosis development.