WorldWideScience

Sample records for standard 3013-99 threshold

  1. 7 CFR 29.3013 - Combination color symbols.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Combination color symbols. 29.3013 Section 29.3013..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER... Type 93) § 29.3013 Combination color symbols. As applied to Burley, combination color symbols are as...

  2. Residual Stresses In 3013 Containers

    International Nuclear Information System (INIS)

    Mickalonis, J.; Dunn, K.

    2009-01-01

    The DOE Complex is packaging plutonium-bearing materials for storage and eventual disposition or disposal. The materials are handled according to the DOE-STD-3013 which outlines general requirements for stabilization, packaging and long-term storage. The storage vessels for the plutonium-bearing materials are termed 3013 containers. Stress corrosion cracking has been identified as a potential container degradation mode and this work determined that the residual stresses in the containers are sufficient to support such cracking. Sections of the 3013 outer, inner, and convenience containers, in both the as-fabricated condition and the closure welded condition, were evaluated per ASTM standard G-36. The standard requires exposure to a boiling magnesium chloride solution, which is an aggressive testing solution. Tests in a less aggressive 40% calcium chloride solution were also conducted. These tests were used to reveal the relative stress corrosion cracking susceptibility of the as fabricated 3013 containers. Significant cracking was observed in all containers in areas near welds and transitions in the container diameter. Stress corrosion cracks developed in both the lid and the body of gas tungsten arc welded and laser closure welded containers. The development of stress corrosion cracks in the as-fabricated and in the closure welded container samples demonstrates that the residual stresses in the 3013 containers are sufficient to support stress corrosion cracking if the environmental conditions inside the containers do not preclude the cracking process.

  3. Net Weight Issue LLNL DOE-STD-3013 Containers

    International Nuclear Information System (INIS)

    Wilk, P

    2008-01-01

    The following position paper will describe DOE-STD-3013 container sets No.L000072 and No.L000076, and how they are compliant with DOE-STD-3013-2004. All masses of accountable nuclear materials are measured on LLNL certified balances maintained under an MC and A Program approved by DOE/NNSA LSO. All accountability balances are recalibrated annually and checked to be within calibration on each day that the balance is used for accountability purposes. A statistical analysis of the historical calibration checks from the last seven years indicates that the full-range Limit of Error (LoE, 95% confidence level) for the balance used to measure the mass of the contents of the above indicated 3013 containers is 0.185 g. If this error envelope, at the 95% confidence level, were to be used to generate an upper-limit to the measured weight of the containers No.L000072 and No.L000076, the error-envelope would extend beyond the 5.0 kg 3013-standard limit on the package contents by less than 0.3 g. However, this is still well within the intended safety bounds of DOE-STD-3013-2004

  4. Complex-wide representation of material packaged in 3013 containers

    Energy Technology Data Exchange (ETDEWEB)

    Narlesky, Joshua E.; Peppers, Larry G.; Friday, Gary P.

    2009-06-01

    The DOE sites packaging plutonium oxide materials packaged according to Department of Energy 3013 Standard (DOE-STD-3013) are responsible for ensuring that the materials are represented by one or more samples in the Materials Identification and Surveillance (MIS) program. The sites categorized most of the materials into process groups, and the remaining materials were characterized, based on the prompt gamma analysis results. The sites issued documents to identify the relationships between the materials packaged in 3013 containers and representative materials in the MIS program. These “Represented” documents were then reviewed and concurred with by the MIS Working Group. However, these documents were developed uniquely at each site and were issued before completion of sample characterization, small-scale experiments, and prompt gamma analysis, which provided more detailed information about the chemical impurities and the behavior of the material in storage. Therefore, based on the most recent data, relationships between the materials packaged in 3013 containers and representative materials in the MIS program been revised. With the prompt gamma analysis completed for Hanford, Rocky Flats, and Savannah River Site 3013 containers, MIS items have been assigned to the 3013 containers for which representation is based on the prompt gamma analysis results. With the revised relationships and the prompt gamma analysis results, a Master “Represented” table has been compiled to document the linkages between each 3013 container packaged to date and its representative MIS items. This table provides an important link between the Integrated Surveillance Program database, which contains information about each 3013 container to the MIS items database, which contains the characterization, prompt gamma data, and storage behavior data from shelf-life experiments for the representative MIS items.

  5. Complex-wide representation of material packaged in 3013 containers

    International Nuclear Information System (INIS)

    Narlesky, Joshua E.; Peppers, Larry G.; Friday, Gary P.

    2009-01-01

    The DOE sites packaging plutonium oxide materials packaged according to Department of Energy 3013 Standard (DOE-STD-3013) are responsible for ensuring that the materials are represented by one or more samples in the Materials Identification and Surveillance (MIS) program. The sites categorized most of the materials into process groups, and the remaining materials were characterized, based on the prompt gamma analysis results. The sites issued documents to identify the relationships between the materials packaged in 3013 containers and representative materials in the MIS program. These 'Represented' documents were then reviewed and concurred with by the MIS Working Group. However, these documents were developed uniquely at each site and were issued before completion of sample characterization, small-scale experiments, and prompt gamma analysis, which provided more detailed information about the chemical impurities and the behavior of the material in storage. Therefore, based on the most recent data, relationships between the materials packaged in 3013 containers and representative materials in the MIS program have been revised. With the prompt gamma analysis completed for Hanford, Rocky Flats, and Savannah River Site 3013 containers, MIS items have been assigned to the 3013 containers for which representation is based on the prompt gamma analysis results. With the revised relationships and the prompt gamma analysis results, a Master 'Represented' table has been compiled to document the linkages between each 3013 container packaged to date and its representative MIS items. This table provides an important link between the Integrated Surveillance Program database, which contains information about each 3013 container to the MIS items database, which contains the characterization, prompt gamma data, and storage behavior data from shelf-life experiments for the representative MIS items

  6. 29 CFR 301.3 - Organization.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 2 2010-07-01 2010-07-01 false Organization. 301.3 Section 301.3 Labor Regulations Relating to Labor NATIONAL RAILROAD ADJUSTMENT BOARD RULES OF PROCEDURE § 301.3 Organization. The National Railroad Adjustment Board was organized as of July 31, 1934, in accordance with the provisions of the...

  7. 49 CFR 38.99 - Floors, steps and thresholds.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Floors, steps and thresholds. 38.99 Section 38.99 Transportation Office of the Secretary of Transportation AMERICANS WITH DISABILITIES ACT (ADA) ACCESSIBILITY SPECIFICATIONS FOR TRANSPORTATION VEHICLES Commuter Rail Cars and Systems § 38.99 Floors, steps and thresholds...

  8. 3013/9975 Surveillance Program Interim Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, K.; Hackney, B.; McClard, J.

    2011-06-22

    Standard moisture limit which was opened at LANL. The container pieces and an oxide sample were sent to SRNL for examination in FY11. No significant pressurization has been observed for the Pressure & Corrosion bin containers. Relatively minor corrosion has been observed on some convenience containers and the inside of two inner containers. While the limited extent of corrosion does not jeopardize the integrity of the outer 3013 containers, it does highlight the importance of continuing to perform DE and the Shelf Life program to assure that the corrosion rate is not accelerating or changing to a different corrosion mechanism (e.g., stress corrosion cracking). Statistical sampling is currently scheduled to be completed in FY17, but there is a proposed reduction of the number of DE's per year for FY11 and beyond which may delay the completion date. Since 3013 containers are stored inside 9975 containers, surveillances of 9975 containers are performed in conjunction with 3013 container surveillances. Results of 9975 container nondestructive examinations (NDEs) and DEs indicate that the containers will provide adequate protection of the 3013 containers in K-Area storage for at least 15 years [Reference 4].

  9. 3013/9975 Surveillance Program Interim Summary Report

    International Nuclear Information System (INIS)

    Dunn, K.; Hackney, B.; McClard, J.

    2011-01-01

    Standard moisture limit which was opened at LANL. The container pieces and an oxide sample were sent to SRNL for examination in FY11. No significant pressurization has been observed for the Pressure and Corrosion bin containers. Relatively minor corrosion has been observed on some convenience containers and the inside of two inner containers. While the limited extent of corrosion does not jeopardize the integrity of the outer 3013 containers, it does highlight the importance of continuing to perform DE and the Shelf Life program to assure that the corrosion rate is not accelerating or changing to a different corrosion mechanism (e.g., stress corrosion cracking). Statistical sampling is currently scheduled to be completed in FY17, but there is a proposed reduction of the number of DE's per year for FY11 and beyond which may delay the completion date. Since 3013 containers are stored inside 9975 containers, surveillances of 9975 containers are performed in conjunction with 3013 container surveillances. Results of 9975 container nondestructive examinations (NDEs) and DEs indicate that the containers will provide adequate protection of the 3013 containers in K-Area storage for at least 15 years (Reference 4).

  10. Remote-Reading Safety and Safeguards Surveillance System for 3013 Containers

    International Nuclear Information System (INIS)

    Lechelt, W. M.; Skorpik, J. R.; Silvers, K. L.; Szempruch, R. W.; Douglas, D. G.; Fein, K. O.

    2002-01-01

    At Hanford's Plutonium Finishing Plant (PFP), plutonium oxide is being loaded into stainless steel containers for long-term storage on the Hanford Site. These containers consist of two weld-sealed stainless steel cylinders nested one within the other. A third container holds the plutonium within the inner cylinder. This design meets the U.S. Department of Energy (DOE) storage standard, DOE-STD- 3013-2000, which anticipates a 50-year storage lifetime. The 3013 standard also requires a container surveillance program to continuously monitor pressure and to assure safeguards are adequate. However, the configuration of the container system makes using conventional measurement and monitoring methods difficult. To better meet the 3013 monitoring requirements, a team from Fluor Hanford (who manages the PFP), Pacific Northwest National Laboratory (PNNL), and Vista Engineering Technologies, LLC, developed a safer, cost-efficient, remote PFP 3013 container surveillance system. This new surveillance system is a combination of two successfully deployed technologies: (1) a magnetically coupled pressure gauge developed by Vista Engineering and (2) a radio frequency (RF) tagging device developed by PNNL. This system provides continuous, 100% monitoring of critical parameters with the containers in place, as well as inventory controls. The 3013 container surveillance system consists of three main elements: (1) an internal magnetic pressure sensor package, (2) an instrument pod (external electronics package), and (3) a data acquisition storage and display computer. The surveillance system described in this paper has many benefits for PFP and DOE in terms of cost savings and reduced personnel exposure. In addition, continuous safety monitoring (i.e., internal container pressure and temperature) of every container is responsible nuclear material stewardship and fully meets and exceeds DOE's Integrated Surveillance Program requirements

  11. TECHNICAL BASIS FOR DOE STANDARD 3013 EQUIVALENCY SUPPORTING REDUCED TEMPERATURE STABILIZATION OF OXALATE-DERIVED PLUTONIUM OXIDE PRODUCED BY THE HB-LINE FACILITY AT SAVANNAH RIVER SITE

    Energy Technology Data Exchange (ETDEWEB)

    Duffey, J.; Livingston, R.; Berg, J.; Veirs, D.

    2012-07-02

    The HB-Line (HBL) facility at the Savannah River Site (SRS) is designed to produce high-purity plutonium dioxide (PuO{sub 2}) which is suitable for future use in production of Mixed Oxide (MOX) fuel. The MOX Fuel Fabrication Facility (MFFF) requires PuO{sub 2} feed to be packaged per the U.S. Department of Energy (DOE) Standard 3013 (DOE-STD-3013) to comply with the facility's safety basis. The stabilization conditions imposed by DOE-STD-3013 for PuO{sub 2} (i.e., 950 C for 2 hours) preclude use of the HBL PuO{sub 2} in direct fuel fabrication and reduce the value of the HBL product as MFFF feedstock. Consequently, HBL initiated a technical evaluation to define acceptable operating conditions for production of high-purity PuO{sub 2} that fulfills the DOE-STD-3013 criteria for safe storage. The purpose of this document is to demonstrate that within the defined operating conditions, the HBL process will be equivalent for meeting the requirements of the DOE-STD-3013 stabilization process for plutonium-bearing materials from the DOE complex. The proposed 3013 equivalency reduces the prescribed stabilization temperature for high-purity PuO{sub 2} from oxalate precipitation processes from 950 C to 640 C and places a limit of 60% on the relative humidity (RH) at the lowest material temperature. The equivalency is limited to material produced using the HBL established flow sheet, for example, nitric acid anion exchange and Pu(IV) direct strike oxalate precipitation with stabilization at a minimum temperature of 640 C for four hours (h). The product purity must meet the MFFF acceptance criteria of 23,600 {micro}g/g Pu (i.e., 2.1 wt %) total impurities and chloride content less than 250 {micro}g/g of Pu. All other stabilization and packaging criteria identified by DOE-STD-3013-2012 or earlier revisions of the standard apply. Based on the evaluation of test data discussed in this document, the expert judgment of the authors supports packaging the HBL product under a 3013

  12. 21 CFR 582.3013 - Ascorbic acid.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Ascorbic acid. 582.3013 Section 582.3013 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS... Ascorbic acid. (a) Product. Ascorbic acid. (b) Conditions of use. This substance is generally recognized as...

  13. 21 CFR 182.3013 - Ascorbic acid.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ascorbic acid. 182.3013 Section 182.3013 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN... acid. (a) Product. Ascorbic acid. (b) Conditions of use. This substance is generally recognized as safe...

  14. Thermal Analysis Of 3013/9975 Configuration

    International Nuclear Information System (INIS)

    Gupta, N.

    2009-01-01

    The 3013 containers are designed in accordance with the DOE-STD-3013-2004 and are qualified to store plutonium (Pu) bearing materials for 50 years. The U.S. Department of Energy (DOE) certified Model 9975 shipping package is used to transport the 3013 containers to the K-Area Material Storage (KAMS) facility at the Savannah River Site (SRS) and to store the containers until the plutonium can be properly dispositioned. Detailed thermal analyses to support the storage in the KAMS facility are given in References 2, 3, and 4. The analyses in this paper serve to provide non-accident condition, non-bounding, specific 3013 container temperatures for use in the surveillance activities. This paper presents a methodology where critical component temperatures are estimated using numerical methods over a range of package and storage parameters. The analyses include factors such as ambient storage temperature and the content weight, density, heat generation rate, and fill height, that may impact the thermal response of the packages. Statistical methods are used to develop algebraic equations for ease of computations to cover the factor space. All computations were performed in BTU-FT-Hr- o F units.

  15. 16 CFR 301.3 - English language requirements.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false English language requirements. 301.3 Section... AND REGULATIONS UNDER FUR PRODUCTS LABELING ACT Regulations § 301.3 English language requirements. All..., shall be set out in the English language. If labels, invoices or advertising matter contain any of the...

  16. 22 CFR 301.3 - Action on requests for declassification review.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Action on requests for declassification review. 301.3 Section 301.3 Foreign Relations PEACE CORPS PUBLIC ACCESS TO CLASSIFIED MATERIAL § 301.3 Action on requests for declassification review. (a) The Director of Security shall present each request for...

  17. The Lawrence Livermore National Laboratory DOE-STD-3013 Surveillance Program for the Storage of Plutonium Packages

    International Nuclear Information System (INIS)

    Riley, D

    2005-01-01

    This document presents a site-specific DOE-STD-3013 (3013) surveillance program for 3013 material stored at Lawrence Livermore National Laboratory (LLNL) in the B332 Plutonium Facility. The 3013 standard requires the development of a surveillance program to assure the long-term safety of plutonium storage in 3013 compliant containers. A complex-wide Integrated Surveillance Program in Support of Long-Term Storage of Plutonium-Bearing Materials (ISP)(LA-UR-00-3246, Revision 1, March 2001) has been developed to give guidance on an acceptable surveillance approach and to set up a mechanism to integrate surveillance activities and facilitate the sharing of lessons learned. This LLNL 3013 surveillance program has been developed following guidelines established for Storage Sites in the ISP and is sufficient for the storage in the LLNL Plutonium Facility. The LLNL 3013 surveillance program must be coupled with the DOE complex wide Materials Identification and Surveillance (MIS) program and the ISP led by Savannah River Site (SRS). These programs support the technical basis for continuing safe storage of plutonium packages and provide the technical basis for the limited scope of the site-specific LLNL 3013 surveillance program. The LLNL 3013 surveillance program calls for surveillance of 3013 packages to begin approximately three years after packaging of the first oxide. One percent of the stored packages per year will be randomly selected and nondestructively examined (NDE) by LLNL per the guidelines of the ISP. Additional packages may be selected for NDE if recommended by the ISP Steering Committee and agreed upon by the MIS Working Group. One selected package will be shipped to SRS for destructive analysis each year starting when SRS can receive them. This is expected to be in FY2007. We expect to store a maximum of 400 3013 packages. This would result in an expected maximum of 4 surveillances per year. The activities outlined in the program evolved from the current

  18. Residual Stress Testing of Outer 3013 Containers

    International Nuclear Information System (INIS)

    Dunn, K.

    2004-01-01

    A Gas Tungsten Arc Welded (GTAW) outer 3013 container and a laser welded outer 3013 container have been tested for residual stresses according to the American Society for Testing Materials (ASTM) Standard G-36-94 [1]. This ASTM standard describes a procedure for conducting stress-corrosion cracking tests in boiling magnesium chloride (MgCl2) solution. Container sections in both the as-fabricated condition as well as the closure welded condition were evaluated. Significantly large residual stresses were observed in the bottom half of the as-fabricated container, a result of the base to can fabrication weld because through wall cracks were observed perpendicular to the weld. This observation indicates that regardless of the closure weld technique, sufficient residual stresses exist in the as-fabricated container to provide the stress necessary for stress corrosion cracking of the container, at the base fabrication weld. Additionally, sufficiently high residual stresses were observed in both the lid and the body of the GTAW as well as the laser closure welded containers. The stresses are oriented perpendicular to the closure weld in both the container lid and the container body. Although the boiling MgCl2 test is not a quantitative test, a comparison of the test results from the closure welds shows that there are noticeably more through wall cracks in the laser closure welded container than in the GTAW closure welded container

  19. Pressure Indication of 3013 Inner Containers Using Digital Radiography

    International Nuclear Information System (INIS)

    HENSEL, SJ

    2004-01-01

    Plutonium bearing materials packaged for long term storage per the Department of Energy Standard 3013 (DOE-STD-3013) are required to be examined periodically in a non-destructive manner (i.e. without compromising the storage containers) for pressure buildup. Radiography is the preferred technology for performing the examinations. The concept is to measure and record the container lid position. As a can pressurizes the lid will deflect outward and thus provide an indication of the internal pressure. A radiograph generated within 30 days of creation of each storage container serves as the baseline from which future surveillance examinations will be compared. A problem with measuring the lid position was discovered during testing of a digital radiography system. The solution was to provide a distinct feature upon the lower surface of the container lid from which the digital radiography system could easily track the lid position

  20. Modifications to LLNL Plutonium Packaging Systems (PuPS) to achieve ASME VIII UW-13.2(d) Requirements for the DOE Standard 3013-00 Outer Can Weld

    International Nuclear Information System (INIS)

    Riley, D; Dodson, K

    2001-01-01

    The Lawrence Livermore National Laboratory (LLNL) Plutonium Packaging System (PuPS) prepares packages to meet the DOE Standard 3013 (Reference 1). The PuPS equipment was supplied by the British Nuclear Fuels Limited (BNFL). The DOE Standard 3013 requires that the welding of the Outer Can meets ASME Section VIII Division 1 (Reference 2). ASME Section VIII references to ASME Section IX (Reference 3) for most of the welding requirements, but UW-13.2 (d) of Section VIII requires a certain depth and width of the weld. In this document the UW-13.2(d) requirement is described as the (a+b)/2t s ratio. This ratio has to be greater than or equal to one to meet the requirements of UW-13.2(d). The Outer Can welds had not been meeting this requirement. Three methods are being followed to resolve this issue: (1) Modify the welding parameters to achieve the requirement, (2) Submit a weld case to ASME that changes the UW-13.2(d) requirement for their review and approval, and (3) Change the requirements in the DOE-STD-3013. Each of these methods are being pursued. This report addresses how the first method was addressed for the LLNL PuPS. The experimental work involved adjusting the Outer Can rotational speed and the power applied to the can. These adjustments resulted in being able to achieve the ASME VIII, UW-13.2(d) requirement

  1. Water bath and air bath calorimeter qualification for measuring 3013 containers of plutonium oxide at the Hanford Plutonium Finishing Plant (PFP)

    International Nuclear Information System (INIS)

    WELSH, T.L.

    2003-01-01

    The purpose of this paper is to present qualification data generated from water and air-bath calorimeters measuring radioactive decay heat from plutonium oxide in DOE STD-3013-2000 (3013) containers at the Hanford Plutonium Finishing Plant (PFP). Published data concerning air and water bath calorimeters and especially 3013-qualified calorimeters is minimal at best. This paper will address the data from the measurement/qualification test plan, the heat standards used, and the calorimeter precision and accuracy results. The 3013 package is physically larger than earlier plutonium oxide storage containers, thereby necessitating a larger measurement chamber. To accommodate the measurements of the 3013 containers at PFP, Los Alamos National Laboratory (LANL) supplied a water bath dual-chambered unit and the Savannah River Technology Center (SRTC) provided two air-bath calorimeters. Both types of Calorimeters were installed in the analytical laboratory at PFP. The larger 3013 containers presented a new set of potential measurement problems: longer counting times, heat conductivity through a much larger container mass and wall thickness, and larger amounts of copper shot to assist sample thermal conductivity. These potential problems were addressed and included in the measurement/qualification test plan

  2. Selection of 3013 Containers for Field Surveillance

    International Nuclear Information System (INIS)

    Larry Peppers; Elizabeth Kelly; James McClard; Gary Friday; Theodore Venetz; Jerry Stakebade

    2007-01-01

    consists of a revision of the earlier statistical sampling report. The requirement of 99.9% probability of observing at least one of the worst 5% (99.9/5%) of the containers with a potential for degradation is used to determine the number of containers in the random sample for the Pressure and Corrosion and the Pressure bins. Sampling requirements for the Innocuous bin are not based on the 99.9/5% requirement; rather, they are based on evaluating the assumption of no significant degradation of, or variability between, containers relative to corrosion or pressure generation within the Innocuous bin population as valid. Section 3 of this report focuses on the actual selection of 3013 containers for surveillance. Surveillance containers are identified by the year that the surveillance should be performed. In addition to the randomly selected containers, containers were selected from the entire population, based on engineering judgment for each of these years. The judgmental sampling targets containers with the greatest potential for gas generation and/or corrosion. The factors used for judgmental sample selection are documented in this section. A more detailed discussion of the FY 2005 sample selection process is contained in the previous FY 2005 sample selection report

  3. Fluor-Hanford 3013 Digital Radiography Dead Zone Mitigation Project Pressure Test Report

    International Nuclear Information System (INIS)

    Gibbs, K.

    2003-01-01

    The use of digital radiographic (DR) measurement of lid deflection as an indication of pressurization of the 3013 inner can was first reported by the Savannah River Technology Center (SRTC). The conclusions of this report were that for cans with relatively large initial concavity, lid deflection could be used to meet the 3013 standard (DOE-STD-3013-2000) requirement for a nondestructive indication of a pressurization of 100 psig. During acceptance testing of the system in the Spring of 2003, it was confirmed that for some cans the DR measured lid deflection could become insensitive to the change in lid deflection when compared to actual mechanical measurements. The basic explanation of this phenomenon is that characteristics of the lid geometry such as tilt and wobble can obfuscate the bottom of the lid where the deflection is measured. The purpose of this report is to document the results of the pressure testing and the efficacy of the alternate imaging and analysis methods developed to mitigate the dead zone problem. Prior to review of the results, a review of the current method and an introduction to the newly developed methods and techniques is provided

  4. Stabilizing And Packaging Pu Materials Per 3013 At SRS

    International Nuclear Information System (INIS)

    STEVE, HENSEL

    2005-01-01

    The Savannah River Site (SRS) began packaging Pu metals into 3013 containers in April, 2003 and oxides in October, 2003. A total of 919 outer 3013 containers were made in the FB-Line at SRS when stabilization and packaging was completed in January, 2005. Experiences, lessons learned, and an overview of packaging activities are presented

  5. Technical basis for storage of elastomer-sealed produce cans in the DOE-STD-3013-94 package

    International Nuclear Information System (INIS)

    Horrell, D.R.; Stakebake, J.L.; Szempruch, R.W.

    1996-11-01

    Department of Energy standard DOE-STD-3013-94 establishes criteria for the long-term packaging of plutonium metal and oxide. The inclusion of organic materials in sealed packages of plutonium may produce gases that contribute to container pressurization. To expedite processing, it would be desirable to permit, within the DOE-outlined criteria, limited amounts of organic materials to be used as a sealing gasket in some packaging containers. This paper presents a technical basis for allowing elastomer-sealed cans to be packaged inside the sealed inner container of a double weld-sealed DOE-STD-3013-94 container system

  6. 15 CFR 301.3 - Application for duty-free entry of scientific instruments.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Application for duty-free entry of scientific instruments. 301.3 Section 301.3 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) INTERNATIONAL TRADE ADMINISTRATION, DEPARTMENT OF COMMERCE MISCELLANEOUS...

  7. Thermal-hydraulic assessment of concrete storage cubicle with horizontal 3013 canisters

    Energy Technology Data Exchange (ETDEWEB)

    HEARD, F.J.

    1999-04-08

    The FIDAP computer code was used to perform a series of analyses to assess the thermal-hydraulic performance characteristics of the concrete plutonium storage cubicles, as modified for the horizontal placement of 3013 canisters. Four separate models were developed ranging from a full height model of the storage cubicle to a very detailed standalone model of a horizontal 3013 canister.

  8. Thermal-hydraulic assessment of concrete storage cubicle with horizontal 3013 canisters

    International Nuclear Information System (INIS)

    Heard, F.J.

    1999-01-01

    The FIDAP computer code was used to perform a series of analyses to assess the thermal-hydraulic performance characteristics of the concrete plutonium storage cubicles, as modified for the horizontal placement of 3013 canisters. Four separate models were developed ranging from a full height model of the storage cubicle to a very detailed standalone model of a horizontal 3013 canister

  9. TEMPERATURE PREDICTION IN 3013 CONTAINERS IN K AREA MATERIAL STORAGE (KAMS) FACILITY USING REGRESSION METHODS

    International Nuclear Information System (INIS)

    Gupta, N

    2008-01-01

    3013 containers are designed in accordance with the DOE-STD-3013-2004. These containers are qualified to store plutonium (Pu) bearing materials such as PuO2 for 50 years. DOT shipping packages such as the 9975 are used to store the 3013 containers in the K-Area Material Storage (KAMS) facility at Savannah River Site (SRS). DOE-STD-3013-2004 requires that a comprehensive surveillance program be set up to ensure that the 3013 container design parameters are not violated during the long term storage. To ensure structural integrity of the 3013 containers, thermal analyses using finite element models were performed to predict the contents and component temperatures for different but well defined parameters such as storage ambient temperature, PuO 2 density, fill heights, weights, and thermal loading. Interpolation is normally used to calculate temperatures if the actual parameter values are different from the analyzed values. A statistical analysis technique using regression methods is proposed to develop simple polynomial relations to predict temperatures for the actual parameter values found in the containers. The analysis shows that regression analysis is a powerful tool to develop simple relations to assess component temperatures

  10. 18 CFR 301.3 - Filing procedures.

    Science.gov (United States)

    2010-04-01

    ... FOR SALES FROM UTILITIES TO BONNEVILLE POWER ADMINISTRATION UNDER NORTHWEST POWER ACT § 301.3 Filing procedures. (a) Bonneville's ASC review procedures. The procedures established by Bonneville's Administrator... Bonneville's ASC review procedures. (b) Exchange Period. The Exchange Period will be equal to the term of...

  11. Over Batch Analysis for the LLNL DOE-STD-3013 Packaging System

    International Nuclear Information System (INIS)

    Riley, D.C.; Dodson, K.

    2009-01-01

    This document addresses the concern raised in the Savannah River Site (SRS) Acceptance Criteria about receiving an item that is over batched by 1.0 kg of fissile materials. This document shows that the occurrence of this is incredible. Some of the Department of Energy Standard 3013 (DOE-STD-3013) requirements are described in Section 2.1. The SRS requirement is discussed in Section 2.2. Section 2.3 describes the way fissile materials are handled in the Lawrence Livermore National Laboratory (LLNL) Plutonium Facility (B332). Based on the material handling discussed in Section 2.3, there are only three errors that could result in a shipping container being over batched. These are: incorrect measurement of the item, selecting the wrong item to package, and packaging two items into a single shipping container. The analysis in Section 3 shows that the first two events are incredible because of the controls that exist at LLNL. The third event is physically impossible. Therefore, it is incredible for an item to be shipped to SRS that is more than 1.0 kg of fissile materials over batched.

  12. Calibration of the Lawrence Livermore National Laboratory Passive-Active Neutron Drum Shuffler for Measurement of Highly Enriched Uranium in Oxides within DOE-STD-3013-2000 Containers

    International Nuclear Information System (INIS)

    Mount, M E; O'Connell, W J

    2005-01-01

    Lawrence Livermore National Laboratory (LLNL) uses the LLNL passive-active neutron drum (PAN) shuffler (Canberra Model JCC-92) for accountability measurement of highly enriched uranium (HEU) oxide and HEU in mixed uranium-plutonium (U-Pu) oxide. In June 2002, at the 43rd Annual Meeting of the Institute of Nuclear Material Management, LLNL reported on an extensive effort to calibrate this shuffler, based on standards measurements and extensive simulations, for HEU oxides and mixed U-Pu oxides in thin-walled primary and secondary containers. In August 2002, LLNL began to also use DOE-STD-3013-2000 containers for HEU oxide and mixed U-Pu oxide. These DOE-STD-3013-2000 containers are comprised of a stainless steel convenience can enclosed in welded stainless steel primary and secondary containers. Compared to the double thin-walled containers, the DOE-STD-3013-2000 containers have substantially thicker walls, and the density of materials in these containers was found to extend over a greater range (1.35 g/cm 3 to 4.62 g/cm 3 ) than foreseen for the double thin-walled containers. Further, the DOE-STD-3013-2000 Standard allows for oxides containing at least 30 wt% Pu plus U whereas the calibration algorithms for thin-walled containers were derived for virtually pure HEU or mixed U-Pu oxides. An initial series of Monte Carlo simulations of the PAN shuffler response to given quantities of HEU oxide and mixed U-Pu oxide in DOE-STD-3013-2000 containers was generated and compared with the response predicted by the calibration algorithms for thin-walled containers. Results showed a decrease on the order of 10% in the count rate, and hence a decrease in the calculated U mass for measured unknowns, with some varying trends versus U mass. Therefore a decision was made to develop a calibration algorithm for the PAN shuffler unique to the DOE-STD-3013-2000 container. This paper describes that effort and selected unknown item measurement results

  13. Assessment of Residual Stresses in 3013 Inner and Outer Containers and Teardrop Samples

    Energy Technology Data Exchange (ETDEWEB)

    Stroud, Mary Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Prime, Michael Bruce [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Veirs, Douglas Kirk [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Berg, John M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Clausen, Bjorn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Worl, Laura Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); DeWald, Adrian T. [Hill Engineering, LLC, Rancho Cordova, CA (United States)

    2015-12-08

    This report is an assessment performed by LANL that examines packaging for plutonium-bearing materials and the resilience of its design. This report discusses residual stresses in the 3013 outer, the SRS/Hanford and RFETS/LLNL inner containers, and teardrop samples used in studies to assess the potential for SCC in 3013 containers. Residual tensile stresses in the heat affected zones of the closure welds are of particular concern.

  14. Assessment of Residual Stresses in 3013 Inner and Outer Containers and Teardrop Samples

    International Nuclear Information System (INIS)

    Stroud, Mary Ann; Prime, Michael Bruce; Veirs, Douglas Kirk; Berg, John M.; Clausen, Bjorn; Worl, Laura Ann; DeWald, Adrian T.

    2015-01-01

    This report is an assessment performed by LANL that examines packaging for plutonium-bearing materials and the resilience of its design. This report discusses residual stresses in the 3013 outer, the SRS/Hanford and RFETS/LLNL inner containers, and teardrop samples used in studies to assess the potential for SCC in 3013 containers. Residual tensile stresses in the heat affected zones of the closure welds are of particular concern.

  15. Corrosion Testing of 304L SS 3013 Inner Container and Teardrop Samples

    Energy Technology Data Exchange (ETDEWEB)

    Tokash, Justin Charles [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hill, Mary Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lillard, Scott [Univ. of Akron, OH (United States); Joyce, Stephen Anthony [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tegtmeier, Eric Lee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Berg, John M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Veirs, Douglas Kirk [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Worl, Laura Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-27

    The Department of Energy (DOE) 3013 Standard specifies a minimum of two containers to be used for the storage of plutonium-bearing materials containing at least 30 wt.% plutonium and uranium. Three nested containers are typically used, the outer, inner, and convenience containers, shown in Figure 1. Both the outer and inner containers are sealed with a weld while the innermost convenience container must not be sealed. Lifetime of the containers is expected to be fifty years. The containers are fabricated of austenitic stainless steels (SS) due to their high corrosion resistance. Potential failure mechanisms of the storage containers have been examined by Kolman and Lillard et al.

  16. Factors influencing moisture analysis in the 3013 destructive examination surveillance program

    Energy Technology Data Exchange (ETDEWEB)

    Scogin, J. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-10-24

    Thermogravimetric analysis of a solid sample with mass spectrometry (TGA-MS) of the evolved gas is used in the destructive examination (DE) portion of the Integrated Surveillance Program to quantify the moisture content of the material stored in a 3013 container. As with any measurement determined from a small sample, the collection, storage, transportation, and handling of the sample can affect its ability to represent the properties of the bulk material. During the course of the DE program, questions have periodically arisen concerning the ability of the moisture sample to reflect reliably the actual moisture content of the entire material stored in the 3013 container. Most concerns are related to the ability to collect a representative sample and to preserve the moisture content of the sample between collection and analysis. Recent delays in analysis caused by maintenance issues with the TGA-MS instrument presented a unique opportunity to document and quantify the effects various factors have on the TGA-MS moisture measurement. This report will use recent data to document the effects that current sample collection and handling practices have on the TGA-MS moisture measurement. Some suggestions will be made which could improve the current sample collection and handling practices for the TGA-MS moisture measurement so that the analytical results more accurately reflect the moisture content of the material stored in the 3013 container.

  17. Factors influencing moisture analysis in the 3013 destructive examination surveillance program

    International Nuclear Information System (INIS)

    Scogin, J. H.

    2017-01-01

    Thermogravimetric analysis of a solid sample with mass spectrometry (TGA-MS) of the evolved gas is used in the destructive examination (DE) portion of the Integrated Surveillance Program to quantify the moisture content of the material stored in a 3013 container. As with any measurement determined from a small sample, the collection, storage, transportation, and handling of the sample can affect its ability to represent the properties of the bulk material. During the course of the DE program, questions have periodically arisen concerning the ability of the moisture sample to reflect reliably the actual moisture content of the entire material stored in the 3013 container. Most concerns are related to the ability to collect a representative sample and to preserve the moisture content of the sample between collection and analysis. Recent delays in analysis caused by maintenance issues with the TGA-MS instrument presented a unique opportunity to document and quantify the effects various factors have on the TGA-MS moisture measurement. This report will use recent data to document the effects that current sample collection and handling practices have on the TGA-MS moisture measurement. Some suggestions will be made which could improve the current sample collection and handling practices for the TGA-MS moisture measurement so that the analytical results more accurately reflect the moisture content of the material stored in the 3013 container.

  18. 14 CFR 151.99 - Modifications of programming standards.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Modifications of programming standards. 151... (CONTINUED) AIRPORTS FEDERAL AID TO AIRPORTS Project Programming Standards § 151.99 Modifications of programming standards. The Director, Airports, Service, or the Regional Director concerned may, on individual...

  19. 49 CFR 30.13 - Restrictions on Federal public works projects: Certification.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Restrictions on Federal public works projects... WORKS CONTRACTS TO SUPPLIERS OF GOODS AND SERVICES OF COUNTRIES THAT DENY PROCUREMENT MARKET ACCESS TO U.S. CONTRACTORS § 30.13 Restrictions on Federal public works projects: Certification. As prescribed...

  20. 77 FR 27550 - Federal Acquisition Regulation; Revision of Cost Accounting Standards Threshold

    Science.gov (United States)

    2012-05-10

    ...] RIN 9000-AM25 Federal Acquisition Regulation; Revision of Cost Accounting Standards Threshold AGENCY... Federal Acquisition Regulation (FAR) to revise the threshold for applicability of cost accounting standards in order to implement a recent rule of the Cost Accounting Standards Board and statutory...

  1. The best-interests standard as threshold, ideal, and standard of reasonableness.

    Science.gov (United States)

    Kopelman, L M

    1997-06-01

    The best-interests standard is a widely used ethical, legal, and social basis for policy and decision-making involving children and other incompetent persons. It is under attack, however, as self-defeating, individualistic, unknowable, vague, dangerous, and open to abuse. The author defends this standard by identifying its employment, first, as a threshold for intervention and judgment (as in child abuse and neglect rulings), second, as an ideal to establish policies or prima facie duties, and, third, as a standard of reasonableness. Criticisms of the best-interests standard are reconsidered after clarifying these different meanings.

  2. Lawrence Livermore National Laboratory Measurements of Plutonium-bearing Oxide in DOE-STD-3013-2000 Containers Using Calorimetry and Gamma Isotopic Analyses

    International Nuclear Information System (INIS)

    Dearborn, D M; Keeton, S C

    2004-01-01

    Lawrence Livermore National Laboratory (LLNL) routinely uses calorimetry and gamma isotopic analyses (Cal/Iso) for the accountability measurement of plutonium (Pu) bearing items. In the past 15 years, the vast majority of those items measured by Cal/Iso were contained in a thin-walled convenience can enclosed in another thin-walled outer container. However, LLNL has recently begun to use DOE-STD-3013-2000 containers as well. These DOE-STD-3013-2000 containers are comprised of a stainless steel convenience can enclosed in welded stainless steel primary and secondary containers. In addition to the fact that the wall thickness of the DOE-STD-3013-2000 containers is much greater than that of other containers in our experience, the DOE-STD-3013-2000 containers appear to have larger thermal insulation characteristics. To date, we have derived Pu-mass values from Cal/Iso measurements of 74 different DOE-STD-3013-2000 containers filled with Pu-bearing oxide or mixed uranium-plutonium (U-Pu) oxide material. Both water-bath and air-bath calorimeters were used for these measurements and both use software to predict when thermal equilibrium is attained. Our experience has shown that after apparent equilibrium has been attained, at least one more complete cycle, and sometimes two or three more complete cycles, is required to gain a measure of true thermal equilibrium. Otherwise, the derived Pu-mass values are less than would be expected from a combination of previously measured Pu-bearing items and would contribute to increased loss in our inventory difference determinations. Conclusions and recommendations drawn from LLNL experience with measurements of Pu mass in Pu-bearing oxide or mixed U-Pu oxide in DOE-STD-3013-2000 containers using the Cal/Iso technique are included

  3. Dissolution Of 3013-DE Sample 10-16

    International Nuclear Information System (INIS)

    Taylor-Pashow, K.

    2011-01-01

    The HB-Line Facility has a long-term mission to dissolve and disposition legacy fissile materials. HB-Line dissolves plutonium dioxide (PuO 2 ) from K-Area parting support of the 3013 Destructive Examination (DE) program. The PuO 2 -bearing solids originate from a variety of unit operations and processing facilities, but all of the material is assumed to be high-fired (i.e., calcined in air for a minimum of two hours at (ge) 750 C). The Savannah River National Laboratory (SRNL) conducted dissolution flowsheet studies on 3013 DE Sample 10-16 (can R610826), which contains weapons-grade plutonium (Pu) as the fissile material. The dissolution flowsheet study was performed for 4 hours at 108 C on unwashed material using 12 M nitric acid (HNO 3 ) containing 0.20 M potassium fluoride (KF). After 4 hours at 108 C, the 239 Pu Equivalent concentration was 32.5 g/L (gamma, 5.0% uncertainty). The insoluble residue comprised 9.88 wt % of the initial bulk weight, and contained 5.31-5.95 wt % of the initial Pu. The residue contained Pu in the highest concentration, followed by tungsten (W). Analyses detected 2,770 mg/L chloride (Cl - ) in the final dissolver solution (3.28 wt %), which is significantly lower than the amount of Cl - detected by prompt gamma (9.86 wt %) and the 3013 DE Surveillance program (14.7 wt %). A low bias in chloride measurement is anticipated due to volatilization during the experiment. Gas generation studies found approximately 60 mL of gas per gram of sample produced during the first 30 minutes of dissolution. Little to no gas was produced after the first 30 minutes. Hydrogen gas (H 2 ) was not detected in the sample. Based on detection limits and accounting for dilution, the generated gas contained 2 , which is well below the 4.0 vol % flammability limit for H 2 in air. Filtration of the dissolver solution occurred readily. When aluminum nitrate nonahydrate (ANN) was added to the filtered dissolver solution at a 3:1 Al:F molar ratio, and stored at room

  4. Sampling and Analysis of the Headspace Gas in 3013 Type Plutonium Storage Containers at Los Alamos National Laboratory

    International Nuclear Information System (INIS)

    Jackson, Jay M.; Berg, John M.; Hill, Dallas D.; Worl, Laura A.; Veirs, Douglas K.

    2012-01-01

    Department of Energy (DOE) sites have packaged approximately 5200 3013 containers to date. One of the requirements specified in DOESTD-3013, which specifies requirements for packaging plutonium bearing materials, is that the material be no greater than 0.5 weight percent moisture. The containers are robust, nested, welded vessels. A shelf life surveillance program was established to monitor these cans over their 50 year design life. In the event pressurization is detected by radiography, it will be necessary to obtain a head space gas sample from the pressurized container. This technique is also useful to study the head space gas in cans selected for random destructive evaluation. The atmosphere is sampled and the hydrogen to oxygen ratio is measured to determine the effects of radiolysis on the moisture in the container. A system capable of penetrating all layers of a 3013 container assembly and obtaining a viable sample of the enclosed gas and an estimate of internal pressure was designed.

  5. Surveillance and Monitoring Program Full-Scale Experiments to Evaluate the Potential for Corrosion in 3013 Containers

    Energy Technology Data Exchange (ETDEWEB)

    Narlesky, Joshua Edward [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Berg, John M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Duque, Juan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Harradine, David Martin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hill, Dallas Dwight [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Kaczar, Gregory Michael [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lillard, R. Scott [Univ. of Akron, OH (United States); Lopez, Annabelle Sarita [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Martinez, Max Alfonso [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Peppers, Larry G. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rios, Daniel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Edward L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stroud, Mary Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Trujillo, Leonardo Alberto [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Veirs, Douglas Kirk [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wilson, Kennard Virden Jr. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Worl, Laura Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-21

    A set of six long-term, full-scale experiments were initiated to determine the type and extent of corrosion that occurs in 3013 containers packaged with chloride-bearing plutonium oxide materials. The materials were exposed to a high relative humidity environment representative of actual packaging conditions for the materials in storage. The materials were sealed in instrumented, inner 3013 containers with corrosion specimens designed to test the corrosiveness of the environment inside the containers under various conditions. This report focuses on initial loading conditions that are used to establish a baseline to show how the conditions change throughout the storage lifetime of the containers.

  6. 46 CFR 54.10-10 - Standard hydrostatic test (modifies UG-99).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Standard hydrostatic test (modifies UG-99). 54.10-10... PRESSURE VESSELS Inspection, Reports, and Stamping § 54.10-10 Standard hydrostatic test (modifies UG-99). (a) All pressure vessels shall satisfactorily pass the hydrostatic test prescribed by this section...

  7. Technical basis for the reduction of the maximum temperature TGA-MS analysis of oxide samples from the 3013 destructive examination program

    International Nuclear Information System (INIS)

    Scogin, J. H.

    2016-01-01

    Thermogravimetric analysis with mass spectroscopy of the evolved gas (TGA-MS) is used to quantify the moisture content of materials in the 3013 destructive examination (3013 DE) surveillance program. Salts frequently present in the 3013 DE materials volatilize in the TGA and condense in the gas lines just outside the TGA furnace. The buildup of condensate can restrict the flow of purge gas and affect both the TGA operations and the mass spectrometer calibration. Removal of the condensed salts requires frequent maintenance and subsequent calibration runs to keep the moisture measurements by mass spectroscopy within acceptable limits, creating delays in processing samples. In this report, the feasibility of determining the total moisture from TGA-MS measurements at a lower temperature is investigated. A temperature of the TGA-MS analysis which reduces the complications caused by the condensation of volatile materials is determined. Analysis shows that an excellent prediction of the presently measured total moisture value can be made using only the data generated up to 700 °C and there is a sound physical basis for this estimate. It is recommended that the maximum temperature of the TGA-MS determination of total moisture for the 3013 DE program be reduced from 1000 °C to 700 °C. It is also suggested that cumulative moisture measurements at 550 °C and 700°C be substituted for the measured value of total moisture in the 3013 DE database. Using these raw values, any of predictions of the total moisture discussed in this report can be made.

  8. Technical basis for the reduction of the maximum temperature TGA-MS analysis of oxide samples from the 3013 destructive examination program

    Energy Technology Data Exchange (ETDEWEB)

    Scogin, J. H. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-03-24

    Thermogravimetric analysis with mass spectroscopy of the evolved gas (TGA-MS) is used to quantify the moisture content of materials in the 3013 destructive examination (3013 DE) surveillance program. Salts frequently present in the 3013 DE materials volatilize in the TGA and condense in the gas lines just outside the TGA furnace. The buildup of condensate can restrict the flow of purge gas and affect both the TGA operations and the mass spectrometer calibration. Removal of the condensed salts requires frequent maintenance and subsequent calibration runs to keep the moisture measurements by mass spectroscopy within acceptable limits, creating delays in processing samples. In this report, the feasibility of determining the total moisture from TGA-MS measurements at a lower temperature is investigated. A temperature of the TGA-MS analysis which reduces the complications caused by the condensation of volatile materials is determined. Analysis shows that an excellent prediction of the presently measured total moisture value can be made using only the data generated up to 700 °C and there is a sound physical basis for this estimate. It is recommended that the maximum temperature of the TGA-MS determination of total moisture for the 3013 DE program be reduced from 1000 °C to 700 °C. It is also suggested that cumulative moisture measurements at 550 °C and 700°C be substituted for the measured value of total moisture in the 3013 DE database. Using these raw values, any of predictions of the total moisture discussed in this report can be made.

  9. Standard guide for the determination of technetium-99 in Soil

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide is intended to serve as a reference for laboratories wishing to perform Tc-99 analyses in soil. Several options are given for selection of a tracer and for the method of extracting the Tc from the soil matrix. Separation of Tc from the sample matrix is performed using an extraction chromatography resin. Options are then given for the determination of the Tc-99 activity in the original sample. It is up to the user to determine which options are appropriate for use, and to generate acceptance data to support the chosen procedure. 1.2 Due to the various extraction methods available, various tracers used, variable detection methods used, and lack of certified reference materials for Tc-99 in soil, there is insufficient data to support a single method written as a standard method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

  10. How Real Detector Thresholds Create False Standard Candles

    International Nuclear Information System (INIS)

    Shahmoradi, Amir; Nemiroff, Robert

    2009-01-01

    GRB satellites are relatively inefficient detectors of dim hard bursts. For example, given two bursts of identical peak luminosity near the detection threshold, a dim soft burst will be preferentially detected over a dim hard burst. This means that a high E peak burst will need a higher peak luminosity to be detected than a low E peak GRB. This purely detector-created attribute will appear as a correlation between E peak and luminosity, and should not be interpreted as a real standard candle effect. This result derives from Monte Carlo simulations utilizing a wide range of initial GRB spectra, and retriggering to create a final ''detected'' sample. In sum, E peak is not a good standard candle, and its appearance as such in seeming correlations such as the Amati and other L iso vs. E peak relations is likely a ghost of real energy-related detection thresholds.

  11. Standardization of Tc-99 by two methods and participation at the CCRI(II)-K2. Tc-99 comparison.

    Science.gov (United States)

    Sahagia, M; Antohe, A; Ioan, R; Luca, A; Ivan, C

    2014-05-01

    The work accomplished within the participation at the 2012 key comparison of Tc-99 is presented. The solution was standardized for the first time in IFIN-HH by two methods: LSC-TDCR and 4π(PC)β-γ efficiency tracer. The methods are described and the results are compared. For the LSC-TDCR method, the program TDCR07c, written and provided by P. Cassette, was used for processing the measurement data. The results are 2.1% higher than when applying the TDCR06b program; the higher value, calculated with the software TDCR07c, was used for reporting the final result in the comparison. The tracer used for the 4π(PC)β-γ efficiency tracer method was a standard (60)Co solution. The sources were prepared from the mixture (60)Co+(99)Tc solution and a general extrapolation curve, type: N(βTc-99)/(M)(Tc-99)=f [1-ε(Co-60)], was drawn. This value was not used for the final result of the comparison. The difference between the values of activity concentration obtained by the two methods was within the limit of the combined standard uncertainty of the difference of these two results. © 2013 Published by Elsevier Ltd.

  12. 28 CFR 30.13 - May the Attorney General waive any provision of these regulations?

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false May the Attorney General waive any... INTERGOVERNMENTAL REVIEW OF DEPARTMENT OF JUSTICE PROGRAMS AND ACTIVITIES § 30.13 May the Attorney General waive any provision of these regulations? In an emergency, the Attorney General may waive any provision of these...

  13. Standardization of Tc-99 by three liquid scintillation counting methods

    International Nuclear Information System (INIS)

    Wyngaardt, W.M. van; Staden, M.J. van; Lubbe, J.; Simpson, B.R.S.

    2014-01-01

    The NMISA participated in the international key comparison of the pure beta-emitter Technetium-99, CCRI(II)-K2.Tc-99. The comparison solution was standardized using three methods, namely the TDCR efficiency calculation method, the CIEMAT/NIST efficiency tracing method and the 4π(LS)β–γ coincidence tracing method with Co-60 as tracer. Excellent agreement between results obtained with the three methods confirmed the applicability of the beta spectral shape given by the latest (2011) DDEP evaluation of Tc-99 decay data, rather than the earlier (2004) evaluation. - Highlights: • Activity concentration of Tc-99 solution measured using three LSC methods. • Methods used are TDCR, CNET and 4π(LS)β–γ coincidence tracing. • Beta spectral shape confirmed by agreement between three methods

  14. Determining the influence of temperature on various types of standard resistors

    CSIR Research Space (South Africa)

    Marais, EL

    2006-10-01

    Full Text Available Types of Standard Resistors Speaker / Author: E.L. Marais CSIR National Metrology Laboratory PO Box 395, Pretoria, 0001, South Africa Email: elmarais@csir.co.za Phone: 012 841 3013 Fax: 012 841 2131 Abstract The temperature coefficient...

  15. Test Plan to Determine the Maximum Surface Temperatures for a Plutonium Storage Cubicle with Horizontal 3013 Canisters

    International Nuclear Information System (INIS)

    HEARD, F.J.

    2000-01-01

    A simulated full-scale plutonium storage cubicle with 22 horizontally positioned and heated 3013 canisters is proposed to confirm the effectiveness of natural circulation. Temperature and airflow measurements will be made for different heat generation and cubicle door configurations. Comparisons will be made to computer based thermal Hydraulic models

  16. Electrolytic decontamination of the 3013 inner can

    International Nuclear Information System (INIS)

    Wedman, D.E.; Nelson, T.O.; Rivera, Y.; Weisbrod, K.; Martinez, H.E.; Limback, S.

    1998-01-01

    Disposition of plutonium recovered from nuclear weapons or production residues must be stored in a manner that ensures safety. The criteria that has been established to assure the safety of stored materials for a minimum of 50 years is DOE-STD-3013. Los Alamos National Laboratory (LANL) has designed a containment package in accordance with the DOE standard. The package consists of an optional convenience (food pack) can, a welded type 304L stainless steel inner (primary) can, and a welded type 304L stainless steel outer (secondary) can. With or without the food pack can, the material is placed inside the primary can and welded shut under a helium atmosphere. This activity takes place totally within the confinement of the glove box line. Following the welding process, the can is checked for leaks and then sent down the line for decontamination. Once decontaminated, the sealed primary can may be removed from the glove box line. Welding of the secondary container takes place outside the glove box line. The highly automated decontamination process that has been developed to support the packaging of Special Nuclear Materials is based on an electrolytic process similar to the wide spread industrial technique of electropolishing. The can is placed within a specially designed stainless steel fixture built within a partition of a glove box. This fixture is then filled with a flowing electrolyte solution. A low DC electric current is made to flow between the can, acting as the anode, and the fixture, acting as the cathode. Following the decontamination, the system provides a flow of rinse water through the fixture to rinse the can of remaining salt residues. The system then carried out a drying cycle. Finally, the fixture is opened from the opposite side of the partition and the can surface monitored directly and through surface smears to assure that decontamination is adequate

  17. Electrolytic decontamination of the 3013 inner can

    International Nuclear Information System (INIS)

    Wedman, D.E.; Nelson, T.O.; Rivera, Y.; Weisbrod, K.; Martinez, H.E.; Limback, S.

    1998-01-01

    Disposition of plutonium recovered from nuclear weapons or production residues must be stored in a manner that ensures safety. The criteria that has been established to assure the safety of stored materials for a minimum of 50 years is DOE-STD-3013. This standard specifies both the requirements for containment and furthermore specifies that the inner container be decontaminated to a level of ≤20 dpm/100 cm 2 swipable and ≤500 dpm/100 cm 2 direct alpha such that a failure of the outer containment barrier will have a lower probability of resulting in a spread of contamination. The package consists of an optional convenience (food pack) can, a welded type 304L stainless steel inner (primary) can, and a welded type 304L stainless steel outer (secondary) can. Following the welding process, the can is checked for leaks and then sent down the line for decontamination. Once decontaminated, the sealed primary can may be removed from the glove box line. Welding of the secondary container takes place outside the glove box line. The highly automated decontamination process that has been developed to support the packaging of Special Nuclear Materials is based on an electrolytic process similar to the wide spread industrial technique of electropolishing. The can is placed within a specially designed stainless steel fixture built within a partition of a glove box. The passage of current through this electrolytic cell results in a uniform anodic dissolution of the surface metal layers of the can. This process results in a rapid decontamination of the can. The electrolyte is fully recyclable, and the separation of the chromium from the actinides results in a compact, non RCRA secondary waste product

  18. PROTOCOL FOR EXAMINATION OF THE INNER CAN CLOSURE WELD REGION FOR 3013 DE CONTAINERS

    Energy Technology Data Exchange (ETDEWEB)

    Mickalonis, J.

    2014-09-16

    The protocol for the examination of the inner can closure weld region (ICCWR) for 3013 DE containers is presented within this report. The protocol includes sectioning of the inner can lid section, documenting the surface condition, measuring corrosion parameters, and storing of samples. This protocol may change as the investigation develops since findings may necessitate additional steps be taken. Details of the previous analyses, which formed the basis for this protocol, are also presented.

  19. Alternative method for determining anaerobic threshold in rowers

    Directory of Open Access Journals (Sweden)

    Giovani Dos Santos Cunha

    2008-01-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2008v10n4p367 In rowing, the standard breathing that athletes are trained to use makes it difficult, or even impossible, to detect ventilatory limits, due to the coupling of the breath with the technical movement. For this reason, some authors have proposed determining the anaerobic threshold from the respiratory exchange ratio (RER, but there is not yet consensus on what value of RER should be used. The objective of this study was to test what value of RER corresponds to the anaerobic threshold and whether this value can be used as an independent parameter for determining the anaerobic threshold of rowers. The sample comprised 23 male rowers. They were submitted to a maximal cardiorespiratory test on a rowing ergometer with concurrent ergospirometry in order to determine VO2máx and the physiological variables corresponding to their anaerobic threshold. The anaerobic threshold was determined using the Dmax (maximal distance method. The physiological variables were classified into maximum values and anaerobic threshold values. The maximal state of these rowers reached VO2 (58.2±4.4 ml.kg-1.min-1, lactate (8.2±2.1 mmol.L-1, power (384±54.3 W and RER (1.26±0.1. At the anaerobic threshold they reached VO2 (46.9±7.5 ml.kg-1.min-1, lactate (4.6±1.3 mmol.L-1, power (300± 37.8 W and RER (0.99±0.1. Conclusions - the RER can be used as an independent method for determining the anaerobic threshold of rowers, adopting a value of 0.99, however, RER should exhibit a non-linear increase above this figure.

  20. QRS Detection Based on Improved Adaptive Threshold

    Directory of Open Access Journals (Sweden)

    Xuanyu Lu

    2018-01-01

    Full Text Available Cardiovascular disease is the first cause of death around the world. In accomplishing quick and accurate diagnosis, automatic electrocardiogram (ECG analysis algorithm plays an important role, whose first step is QRS detection. The threshold algorithm of QRS complex detection is known for its high-speed computation and minimized memory storage. In this mobile era, threshold algorithm can be easily transported into portable, wearable, and wireless ECG systems. However, the detection rate of the threshold algorithm still calls for improvement. An improved adaptive threshold algorithm for QRS detection is reported in this paper. The main steps of this algorithm are preprocessing, peak finding, and adaptive threshold QRS detecting. The detection rate is 99.41%, the sensitivity (Se is 99.72%, and the specificity (Sp is 99.69% on the MIT-BIH Arrhythmia database. A comparison is also made with two other algorithms, to prove our superiority. The suspicious abnormal area is shown at the end of the algorithm and RR-Lorenz plot drawn for doctors and cardiologists to use as aid for diagnosis.

  1. Alternative method for determining anaerobic threshold in rowers

    Directory of Open Access Journals (Sweden)

    Giovani dos Santos Cunha

    2008-12-01

    Full Text Available In rowing, the standard breathing that athletes are trained to use makes it difficult, or even impossible, to detectventilatory limits, due to the coupling of the breath with the technical movement. For this reason, some authors have proposeddetermining the anaerobic threshold from the respiratory exchange ratio (RER, but there is not yet consensus on what valueof RER should be used. The objective of this study was to test what value of RER corresponds to the anaerobic thresholdand whether this value can be used as an independent parameter for determining the anaerobic threshold of rowers. Thesample comprised 23 male rowers. They were submitted to a maximal cardiorespiratory test on a rowing ergometer withconcurrent ergospirometry in order to determine VO2máx and the physiological variables corresponding to their anaerobicthreshold. The anaerobic threshold was determined using the Dmax (maximal distance method. The physiological variableswere classified into maximum values and anaerobic threshold values. The maximal state of these rowers reached VO2(58.2±4.4 ml.kg-1.min-1, lactate (8.2±2.1 mmol.L-1, power (384±54.3 W and RER (1.26±0.1. At the anaerobic thresholdthey reached VO2 (46.9±7.5 ml.kg-1.min-1, lactate (4.6±1.3 mmol.L-1, power (300± 37.8 W and RER (0.99±0.1. Conclusions- the RER can be used as an independent method for determining the anaerobic threshold of rowers, adopting a value of0.99, however, RER should exhibit a non-linear increase above this figure.

  2. Selection of 3013 containers for field surveillance: LA-14310, Revision 1

    International Nuclear Information System (INIS)

    Peppers, Larry; Kelly, Elizabeth; McClard, James; Friday, Gary; Venetz, Theodore; Stakebake, Jerry

    2009-01-01

    This document is the fifth in a series of reports that document the binning, statistical sampling, and sample selection of 3013 containers for field surveillance. 1,2,3,39 Revisions to binning assignments documented in this report are primarily a result of new prompt gamma data. This report also documents changes to the random sample specification resulting from these binning changes and identifies and provides the rationale for the engineering judgment sample items for Fiscal Year (FY) 2008 and 2009. This revision also updates the changes to the previous surveillance sample resulting from changes to the order that specific containers undergo surveillance. This report will continue to be reviewed regularly and revised as needed to meet the requirements of the surveillance program.

  3. 76 FR 79545 - Cost Accounting Standards: Change to the CAS Applicability Threshold for the Inflation Adjustment...

    Science.gov (United States)

    2011-12-22

    ... Cost Accounting Standards: Change to the CAS Applicability Threshold for the Inflation Adjustment to... Federal Procurement Policy, Cost Accounting Standards Board. ACTION: Final rule. SUMMARY: The Office of Federal Procurement Policy (OFPP), Cost Accounting Standards (CAS) Board (Board), has adopted, without...

  4. Additional diagnostic value of 99Tcm-MIBI imaging over 'cold' nodules in 99Tcm thyroid imaging proved by ROC analysis

    International Nuclear Information System (INIS)

    Mei Ping; Qin Yongde; Wang Saigang; Ruxianguli; Baya; Lv Jie; Xie Bing; Sun Xiaoyan

    2007-01-01

    Objective: More studies have found that 99 Tc m -MIBI thyroid imaging may provide more differential diagnostic value than traditional 99 Tc m O 4 - thyroid imaging. This study attempted to analyze the receiver operating characteristic (ROC) curves to verify the additional diagnostic value of 99 Tc m -MIBI over 99 Tc m O 4 - thyroid imaging in the differentiation of the 'cold' nodules. Methods: Sixty-eight patients initially diagnosed with 'cold' nodules in 99 Tc m O 4 - thyroid scintigraphy were selected for further 99 Tc m -MIBI thyroid imaging at early (15 min after 99 Tc m -MIBI intravenous injection, ER) and delayed phase (2 h after injection, DR). Semi-quantitative analysis was performed using tumor/normal tissue (T/N) ratio both at ER and DR, with 0.8 defined as the threshold for differential diagnoses. In ROC curves analyses, the ratios from tumor/submaxillary gland (T/S) and tumor/heart (T/H) were derived to obtain the most proper differential diagnostic thresholds. Results: Of all patients with the 'cold' nodules, only eight cases were finally diagnosed on pathology with thyroid malignancy, while other 60 were benign. For differential diagnoses, the sensitivity, specificity and accuracy of semi-quantitative 99 Tc m -MIBI thyroid imaging were 100.0%, 76.7% and 79.4% respectively. However, with thresholds of T/N=0.995, T/S=0.995, T/H=1.005 derived from ROC curves for DR 99 Tc m -MIBI imaging, the differential diagnostic sensitivities were 100.0%, 87.5%, 75.0% and the specificities were 90.0%, 85.0%, 83.3% respectively. The areas under the ROC curves were 0.949, 0.876 and 0. 867 respectively for DR, all significantly larger than those of ER. Statistical difference was also evident between threshold values of 0.8 and 0.995 (χ 2 =6.125, P 99 Tc m -MIBI thyroid imaging provide additional diagnostic value over 99 Tc m O 4 - thyroid imaging for the differentiation of the 'cold' nodules. For 99 Tc m -MIBI thyroid imaging, DR is more valuable than ER in the ROC

  5. Accuracy of 99Molybdenum assays in /sup 99m/Technetium solutions

    International Nuclear Information System (INIS)

    Williams, C.C.; Kereiakes, J.G.; Grossman, L.W.

    1981-01-01

    A study was performed to determine the accuracy of 99 Mo measurements using three commercial dose calibrators with their 99 Mo assay shields. One 99 Mo assay shield allowed excessive penetration by the lower energy /sup 99m/Tc photons, resulting in the calibrator's falsely high interpretation of the activity of 99 Mo present in the high-activity /sup 99m/Tc eluates. All three calibrators performed adequately with a National Bureau of Standards 99 Mo standard in equilibrium with /sup 99m/Tc. By using low-activity aliquots of 99 Mo and /sup 99m/Tc, a low-level linearity test was performed. Only one of the calibrators was found to reflect accurately the activity of 99 Mo present under all conditions tested

  6. Molybdenum-99-producing 37-element fuel bundle neutronically and thermal-hydraulically equivalent to a standard CANDU fuel bundle

    Energy Technology Data Exchange (ETDEWEB)

    Nichita, E., E-mail: Eleodor.Nichita@uoit.ca; Haroon, J., E-mail: Jawad.Haroon@uoit.ca

    2016-10-15

    Highlights: • A 37-element fuel bundle modified for {sup 99}Mo production in CANDU reactors is presented. • The modified bundle is neutronically and thermal-hydraulically equivalent to the standard bundle. • The modified bundle satisfies all safety criteria satisfied by the standard bundle. - Abstract: {sup 99m}Tc, the most commonly used radioisotope in diagnostic nuclear medicine, results from the radioactive decay of {sup 99}Mo which is currently being produced at various research reactors around the globe. In this study, the potential use of CANDU power reactors for the production of {sup 99}Mo is investigated. A modified 37-element fuel bundle, suitable for the production of {sup 99}Mo in existing CANDU-type reactors is proposed. The new bundle is specifically designed to be neutronically and thermal-hydraulically equivalent to the standard 37-element CANDU fuel bundle in normal, steady-state operation and, at the same time, be able to produce significant quantities of {sup 99}Mo when irradiated in a CANDU reactor. The proposed bundle design uses fuel pins consisting of a depleted-uranium centre surrounded by a thin layer of low-enriched uranium. The new molybdenum-producing bundle is analyzed using the lattice transport code DRAGON and the diffusion code DONJON. The proposed design is shown to produce 4081 six-day Curies of {sup 99}Mo activity per bundle when irradiated in the peak-power channel of a CANDU core, while maintaining the necessary reactivity and power rating limits. The calculated {sup 99}Mo yield corresponds to approximately one third of the world weekly demand. A production rate of ∼3 bundles per week can meet the global demand of {sup 99}Mo.

  7. Particles near threshold

    International Nuclear Information System (INIS)

    Bhattacharya, T.; Willenbrock, S.

    1993-01-01

    We propose returning to the definition of the width of a particle in terms of the pole in the particle's propagator. Away from thresholds, this definition of width is equivalent to the standard perturbative definition, up to next-to-leading order; however, near a threshold, the two definitions differ significantly. The width as defined by the pole position provides more information in the threshold region than the standard perturbative definition and, in contrast with the perturbative definition, does not vanish when a two-particle s-wave threshold is approached from below

  8. Selection of 3013 Containers for Field Surveillance. Fiscal Year 2016 Update

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Elizabeth J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Berg, John M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Cheadle, Jesse [Savannah River Nuclear Solutions, LLC, (SRNS), Aiken, SC (United States); McClard, James [Project Services Group LLC, Suwanee, GA (United States); Veirs, Douglas Kirk [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-04-19

    This update is the eighth in a series of reports that document the binning and sample selection of 3013 containers for the Field Surveillance program as part of the Integrated Surveillance Program. This report documents changes made to both the container binning assignments and the sample selection approach. Binning changes documented in this update are a result of changes to the prompt gamma calibration curves and the reassignment of a small number of Hanford items from the Pressure bin to the Pressure and Corrosion (P&C) bin. Field Surveillance sample selection changes are primarily a result of focusing future destructive examinations (DEs) on the potential for stress corrosion cracking in higher moisture containers in the P&C bin. The decision to focus the Field Surveillance program on higher moisture items is based on findings from both the Shelf-life testing program and DEs.

  9. 49 CFR 99.735-1 - Cross-reference to ethical conduct standards and financial disclosure regulations.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Cross-reference to ethical conduct standards and... Transportation EMPLOYEE RESPONSIBILITIES AND CONDUCT General § 99.735-1 Cross-reference to ethical conduct... the executive branch-wide Standards of Ethical Conduct at 5 CFR part 2635, the Department of...

  10. Maintenance Action Work Plan for Waste Area Grouping 1 inactive tanks 3001-B, 3004-B, T-30, and 3013 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program

    International Nuclear Information System (INIS)

    1995-07-01

    This Maintenance Action Work Plan has been prepared to document the activities and procedures for the remediation of four inactive, low-level radioactive tanks at Waste Area Grouping 1, from the Category D list of tanks in the Federal Facility Agreement for the Oak Ridge Reservation (EPA et al. 1994). The four tanks to remediated are tanks 3001-B, 3004-B, T-30, and 3013. Three of the tanks (3001-B, 3004-B, and T-30) will be physically removed from the ground. Because of logistical issues associted with excavation and site access, the fourth tank (3013) will be grouted in place and permanently closed

  11. Human reliability assessment in a 99Mo/99mTc generator production facility using the standardized plant analysis risk-human (SPAR-H) technique.

    Science.gov (United States)

    Eyvazlou, Meysam; Dadashpour Ahangar, Ali; Rahimi, Azin; Davarpanah, Mohammad Reza; Sayyahi, Seyed Soheil; Mohebali, Mehdi

    2018-02-13

    Reducing human error is an important factor for enhancing safety protocols in various industries. Hence, analysis of the likelihood of human error in nuclear industries such as radiopharmaceutical production facilities has become more essential. This cross-sectional descriptive study was conducted to quantify the probability of human errors in a 99 Mo/ 99m Tc generator production facility in Iran. First, through expert interviews, the production process of the 99 Mo/ 99m Tc generator was analyzed using hierarchical task analysis (HTA). The standardized plant analysis risk-human (SPAR-H) method was then applied in order to calculate the probability of human error. Twenty tasks were determined using HTA. All of the eight performance shaping factors (PSF S ) were evaluated for the tasks. The mean probability of human error was 0.320. The highest and the lowest probability of human error in the 99 Mo/ 99m Tc generator production process, related to the 'loading the generator with the molybdenum solution' task and the 'generator elution' task, were 0.858 and 0.059, respectively. Required measures for reducing the human error probability (HEP) were suggested. These measures were derived from the level of PSF S that were evaluated in this study.

  12. Different uptake of 99mTc-ECD adn 99mTc-HMPAO in the same brains: analysis by statistical parametric mapping.

    Science.gov (United States)

    Hyun, Y; Lee, J S; Rha, J H; Lee, I K; Ha, C K; Lee, D S

    2001-02-01

    The purpose of this study was to investigate the differences between technetium-99m ethyl cysteinate dimer (99mTc-ECD) and technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) uptake in the same brains by means of statistical parametric mapping (SPM) analysis. We examined 20 patients (9 male, 11 female, mean age 62+/-12 years) using 99mTc-ECD and 99mTc-HMPAO single-photon emission tomography (SPET) and magnetic resonance imaging (MRI) of the brain less than 7 days after onset of stroke. MRI showed no cortical infarctions. Infarctions in the pons (6 patients) and medulla (1), ischaemic periventricular white matter lesions (13) and lacunar infarction (7) were found on MRI. Split-dose and sequential SPET techniques were used for 99mTc-ECD and 99mTc-HMPAO brain SPET, without repositioning of the patient. All of the SPET images were spatially transformed to standard space, smoothed and globally normalized. The differences between the 99mTc-ECD and 99mTc-HMPAO SPET images were statistically analysed using statistical parametric mapping (SPM) 96 software. The difference between two groups was considered significant at a threshold of uncorrected P values less than 0.01. Visual analysis showed no hypoperfused areas on either 99mTc-ECD or 99mTc-HMPAO SPET images. SPM analysis revealed significantly different uptake of 99mTc-ECD and 99mTc-HMPAO in the same brains. On the 99mTc-ECD SPET images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the left superior temporal lobe and in the superior region of the cerebellum. On the 99mTc-HMPAO SPET images, relatively higher uptake was observed in the medial temporal lobes, thalami, periventricular white matter and brain stem. These differences in uptake of the two tracers in the same brains on SPM analysis suggest that interpretation of cerebral perfusion is possible using SPET with 99mTc-ECD and 99mTc-HMPAO.

  13. Altered [99mTc]Tc-MDP biodistribution from neutron activation sourced 99Mo.

    Science.gov (United States)

    Demeter, Sandor; Szweda, Roman; Patterson, Judy; Grigoryan, Marine

    2018-01-01

    Given potential worldwide shortages of fission sourced 99 Mo/ 99m Tc medical isotopes there is increasing interest in alternate production strategies. A neutron activated 99 Mo source was utilized in a single center phase III open label study comparing 99m Tc, as 99m Tc Methylene Diphosphonate ([ 99m Tc]Tc-MDP), obtained from solvent generator separation of neutron activation produced 99 Mo, versus nuclear reactor produced 99 Mo (e.g., fission sourced) in oncology patients for which an [ 99m Tc]Tc-MDP bone scan would normally have been indicated. Despite the investigational [ 99m Tc]Tc-MDP passing all standard, and above standard of care, quality assurance tests, which would normally be sufficient to allow human administration, there was altered biodistribution which could lead to erroneous clinical interpretation. The cause of the altered biodistribution remains unknown and requires further research.

  14. Project management plan for inactive tanks 3001-B, 3004-B, 3013, and T-30 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program

    International Nuclear Information System (INIS)

    1995-07-01

    *This document identifies the roles and responsibilities of the project team members and identifies the project scope, schedule, and cost reporting activities for a maintenance activity to remove and dispose of three inactive liquid low-level radioactive waste (LLLW) system tanks and to isolate and fill one LLLW tank with grout. Tanks 3001-B, 3004-B, and T-30 are located in concrete vaults and tank 3013 is buried directly in the soil. The maintenance project consists of cutting the existing pipes attached to the tanks; capping the piping to be left in place; removing the tanks and filling the vaults with grout for tanks 3001-B, 3004-B, and T-30; and filling tank 3013 with grout. Because the LLLW line serving tank 3001-B will be needed for discharging the 3001 canal demineralizer back flush and regeneration waste to tank WC-19, tank 3001-B will be replaced with a section of piping

  15. Determination of technetium-99 in environmental standard reference materials by ICP-MS

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2000-01-01

    Technetium-99 is an artificial radionuclide which is produced in the fission of 235 U or 239 Pu with a relatively high fission yield of ca. 6%. Because of its long half-life of 2.1 x 10 5 y, 99 Tc has been accumulating in the environment, and thus, is considered to present a potential risk for humans. It is important for dose assessments to identify the behavior of the nuclide in the environment. Analysis data of global fallout 99 Tc in environmental samples would give useful information for predicting the nuclide's behavior; however, due to its low concentration and analytical difficulties, not much data are available. Besides, no environmental standard reference material (SRM) for 99 Tc is available. If we could get suitable SRMs for 99 Tc analysis, it would be easier to determine the concentration of 99 Tc in environmental samples. The purpose of this study was to investigate the possibility of several SRMs to be used as references for low-level 99 Tc. For this, ICP-MS was used for 99 Tc determination. In recent years, ICP-MS has been used for 99 Tc measurements instead of radioactivity counting methods. The samples used were as follows: A) IAEA-373 (a grass sample collected on grassland near Chernobyl Nuclear Power Reactor, Ukraine), B) IAEA-375 (a soil sample collected on a field near Chernobyl Nuclear Power Reactor, Russia), C) IAEA-135 (a sea sediment sample affected by Sellafield, UK), D) five seaweed samples of which the concentration levels are different from each other (collected around the coast near Sellafield, UK). Throughout the chemical separation, 95m Tc was used as a yield monitor. The sample was incinerated for at least 2 h at 450degC. After 99 Tc extraction from the sample at 90degC for 3 h with 4M HNO 3 , the sample was filtered and the residue on the filter was washed with deionized water. The solution was diluted to ca. 0.1M HNO 3 then passed through TEVA resin column (EIChroM Industries, Inc.) to extract Tc onto the resin. Then Tc was

  16. Determination and validation of soil thresholds for cadmium based on food quality standard and health risk assessment.

    Science.gov (United States)

    Ding, Changfeng; Ma, Yibing; Li, Xiaogang; Zhang, Taolin; Wang, Xingxiang

    2018-04-01

    Cadmium (Cd) is an environmental toxicant with high rates of soil-plant transfer. It is essential to establish an accurate soil threshold for the implementation of soil management practices. This study takes root vegetable as an example to derive soil thresholds for Cd based on the food quality standard as well as health risk assessment using species sensitivity distribution (SSD). A soil type-specific bioconcentration factor (BCF, ratio of Cd concentration in plant to that in soil) generated from soil with a proper Cd concentration gradient was calculated and applied in the derivation of soil thresholds instead of a generic BCF value to minimize the uncertainty. The sensitivity variations of twelve root vegetable cultivars for accumulating soil Cd and the empirical soil-plant transfer model were investigated and developed in greenhouse experiments. After normalization, the hazardous concentrations from the fifth percentile of the distribution based on added Cd (HC5 add ) were calculated from the SSD curves fitted by Burr Type III distribution. The derived soil thresholds were presented as continuous or scenario criteria depending on the combination of soil pH and organic carbon content. The soil thresholds based on food quality standard were on average 0.7-fold of those based on health risk assessment, and were further validated to be reliable using independent data from field survey and published articles. The results suggested that deriving soil thresholds for Cd using SSD method is robust and also applicable to other crops as well as other trace elements that have the potential to cause health risk issues. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Determination of 99Mo contamination in 99mTc elute obtained from 99Mo/99mTc- generator

    International Nuclear Information System (INIS)

    Momennezhad, M.; Zakavi, S. R.; Sadeghi, R.

    2010-01-01

    99m Tc is a widely used radioisotope in nuclear medicine centers which is obtained by elution from Mo-99/Tc-99m generators. Usually the generators are either supplied by the Iran Atomic Energy Agency or by private companies from foreign countries. In this study we have measured 99 Mo contamination in 99m Tc elute from different generators in a period of one year. Materials and Methods: The radionuclide impurity of the 99m Tc elute were studied in two types of radionuclide generators (A: produced in Iran and B: Imported from other country). In-vitro measurements were performed using dose calibrator. Direct measurements were made, using a standard canister at the time of milking of the generators and also in Subsequent hours after milking. Results: The results showed a mean of 99 Mo impurity in generators A and B to be 0.00932±0.0043 and 0.0170±0.0127 respectively. Although the results showed that the 99 Mo contamination in 99 mTc elute was lesser than the maximum accepted activity limit of 0.015%, the difference in these two types may reflect different methods of productions of generator, as well as the quality control procedures. Conclusion: The mean of 99 Mo contamination in generators produced in Iran Atomic Energy Organization was lesser than generators imported from foreign origin.

  18. Project Execution Plan Project 98L-EWW-460 Plutonium Stabilization and Handling DOE 98-D-453

    International Nuclear Information System (INIS)

    MCGRATH, G.M.

    2000-01-01

    This Project Execution Plan (PEP) describes the management methods and responsibilities of the project participants. Project W-460 is sufficiently large to warrant a stand alone PEP. This project specific PEP describes the relationships and responsibilities of the project team and identifies the technical, schedule, and cost baselines that have been established for the project. The Department of Energy (DOE), Hanford Works (Hanford), at Richland, Wa. currently does not have a system capable of stabilizing or packaging large quantities of plutonium-bearing solids to meet DOE technical standard DOE-STD-3013-99. This project will allow Hanford to meet this standard by installing stabilization and packaging equipment (SPE). The SPE is capable of stabilizing and packaging the current inventory of greater than 30 percent plutonium-bearing materials currently stored in the Plutonium Finishing Plant's (PFP) vaults into 3013 storage containers. The scope of this project is to procure and install the SPE via a Hanford contract and coordination with the Savannah River Site. In addition, the project will modify PFP vaults and upgrade the PFP Laboratory measurement systems. The Facility infrastructure will be modified to support the new SPE system and the new standardized storage container configuration

  19. Project Execution Plan Project 98L-EWW-460 Plutonium Stabilization and Handling DOE 98-D-453

    Energy Technology Data Exchange (ETDEWEB)

    MCGRATH, G.M.

    2000-06-21

    This Project Execution Plan (PEP) describes the management methods and responsibilities of the project participants. Project W-460 is sufficiently large to warrant a stand alone PEP. This project specific PEP describes the relationships and responsibilities of the project team and identifies the technical, schedule, and cost baselines that have been established for the project. The Department of Energy (DOE), Hanford Works (Hanford), at Richland, Wa. currently does not have a system capable of stabilizing or packaging large quantities of plutonium-bearing solids to meet DOE technical standard DOE-STD-3013-99. This project will allow Hanford to meet this standard by installing stabilization and packaging equipment (SPE). The SPE is capable of stabilizing and packaging the current inventory of greater than 30 percent plutonium-bearing materials currently stored in the Plutonium Finishing Plant's (PFP) vaults into 3013 storage containers. The scope of this project is to procure and install the SPE via a Hanford contract and coordination with the Savannah River Site. In addition, the project will modify PFP vaults and upgrade the PFP Laboratory measurement systems. The Facility infrastructure will be modified to support the new SPE system and the new standardized storage container configuration.

  20. Different uptake of {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO in the same brains: analysis by statistical parametric mapping

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, I.Y. [Dept. of Nuclear Medicine, Inha University College of Medicine, Incheon (Korea); Lee, J.S.; Lee, D.S. [Dept. of Nuclear Medicine, Seoul National University College of Medicine, Seoul (Korea); Rha, J.H.; Lee, I.K.; Ha, C.K. [Dept. of Neurology, Inha University College of Medicine, Incheon (Korea)

    2001-02-01

    The purpose of this study was to investigate the differences between technetium-99m ethyl cysteinate dimer ({sup 99m}Tc-ECD) and technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) uptake in the same brains by means of statistical parametric mapping (SPM) analysis. We examined 20 patients (9 male, 11 female, mean age 62{+-}12 years) using {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO single-photon emission tomography (SPET) and magnetic resonance imaging (MRI) of the brain less than 7 days after onset of stroke. MRI showed no cortical infarctions. Infarctions in the pons (6 patients) and medulla (1), ischaemic periventricular white matter lesions (13) and lacunar infarction (7) were found on MRI. Split-dose and sequential SPET techniques were used for {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO brain SPET, without repositioning of the patient. All of the SPET images were spatially transformed to standard space, smoothed and globally normalized. The differences between the {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO SPET images were statistically analysed using statistical parametric mapping (SPM) 96 software. The difference between two groups was considered significant at a threshold of uncorrected P values less than 0.01. Visual analysis showed no hypoperfused areas on either {sup 99m}Tc-ECD or {sup 99m}Tc-HMPAO SPET images. SPM analysis revealed significantly different uptake of {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO in the same brains. On the {sup 99m}Tc-ECD SPET images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the left superior temporal lobe and in the superior region of the cerebellum. On the {sup 99m}Tc-HMPAO SPET images, relatively higher uptake was observed in the medial temporal lobes, thalami, periventricular white matter and brain stem. These differences in uptake of the two tracers in the same brains on SPM analysis suggest that interpretation of cerebral perfusion is possible using SPET with {sup 99m}Tc-ECD and

  1. 40 CFR 86.1708-99 - Exhaust emission standards for 1999 and later light-duty vehicles.

    Science.gov (United States)

    2010-07-01

    ... for Light-Duty Vehicles and Light-Duty Trucks § 86.1708-99 Exhaust emission standards for 1999 and... are incorporated by reference (see § 86.1). (v) Hybrid electric vehicle requirements. Deterioration factors for hybrid electric vehicles shall be based on the emissions and mileage accumulation of the...

  2. Evaluation Of Plutonium Oxide Destructive Chemical Analyses For Validity Of Original 3013 Container Binning

    International Nuclear Information System (INIS)

    Mcclard, J.; Kessinger, G.

    2010-01-01

    The surveillance program for 3013 containers is based, in part, on the separation of containers into various bins related to potential container failure mechanisms. The containers are assigned to bins based on moisture content and pre-storage estimates of content chemistry. While moisture content is measured during the packaging of each container, chemistry estimates are made by using a combination of process knowledge, packaging data and prompt gamma analyses to establish the moisture and chloride/fluoride content of the materials. Packages with high moisture and chloride/fluoride contents receive more detailed surveillances than packages with less chloride/fluoride and/or moisture. Moisture verification measurements and chemical analyses performed during the surveillance program provided an opportunity to validate the binning process. Validation results demonstrated that the binning effort was generally successful in placing the containers in the appropriate bin for surveillance and analysis.

  3. The rubber hand illusion increases heat pain threshold.

    Science.gov (United States)

    Hegedüs, G; Darnai, G; Szolcsányi, T; Feldmann, Á; Janszky, J; Kállai, J

    2014-09-01

    Accumulating evidence shows that manipulations of cortical body representation, for example, by simply viewing one's own body, can relieve pain in healthy subjects. Despite the widespread use of the rubber hand illusion (RHI) as an effective experimental tool for the manipulation of bodily awareness, previous studies examining the analgesic effect of the RHI have produced conflicting results. We used noxious heat stimuli to induce finger pain in 29 healthy subjects, and we recorded the participants' pain thresholds and subjective pain ratings during the RHI and during the control conditions. Two control conditions were included in our experiment - a standard one with reduced illusion strength (asynchronous stroking control) and an additional one in which the participants viewed their own hand. Raw data showed that both the RHI and the vision of the own hand resulted in slightly higher pain thresholds than the asynchronous stroking control (illusion: 47.79 °C; own-hand: 47.99 °C; asynchronous: 47.52 °C). After logarithmic transformation to achieve normality, paired t-tests revealed that both increases in pain threshold were significant (illusion/asynchronous: p = 0.036; own-hand/asynchronous: p = 0.007). In contrast, there was no significant difference in pain threshold between the illusion and the own-hand conditions (p = 0.656). Pain rating scores were not log-normal, and Wilcoxon singed-rank tests found no significant differences in pain ratings between the study conditions. The RHI increases heat pain threshold and the analgesic effect of the RHI is comparable with that of seeing one's own hand. The latter finding may have clinical implications. © 2014 European Pain Federation - EFIC®

  4. Meeting Threshold Learning Standards through Self-Management in Group Oral Presentations: Observations on Accounting Postgraduate Students

    Science.gov (United States)

    Shauki, Elvia R.; Benzie, Helen

    2017-01-01

    This study explores the development of student self-management skills through an oral presentation task. It is motivated by the challenge to maintain consistent quality in students' oral skills and to incorporate national accounting curriculum requirements for threshold learning standards into an accounting subject. The study has been conducted in…

  5. Identification of ecological thresholds from variations in phytoplankton communities among lakes: contribution to the definition of environmental standards.

    Science.gov (United States)

    Roubeix, Vincent; Danis, Pierre-Alain; Feret, Thibaut; Baudoin, Jean-Marc

    2016-04-01

    In aquatic ecosystems, the identification of ecological thresholds may be useful for managers as it can help to diagnose ecosystem health and to identify key levers to enable the success of preservation and restoration measures. A recent statistical method, gradient forest, based on random forests, was used to detect thresholds of phytoplankton community change in lakes along different environmental gradients. It performs exploratory analyses of multivariate biological and environmental data to estimate the location and importance of community thresholds along gradients. The method was applied to a data set of 224 French lakes which were characterized by 29 environmental variables and the mean abundances of 196 phytoplankton species. Results showed the high importance of geographic variables for the prediction of species abundances at the scale of the study. A second analysis was performed on a subset of lakes defined by geographic thresholds and presenting a higher biological homogeneity. Community thresholds were identified for the most important physico-chemical variables including water transparency, total phosphorus, ammonia, nitrates, and dissolved organic carbon. Gradient forest appeared as a powerful method at a first exploratory step, to detect ecological thresholds at large spatial scale. The thresholds that were identified here must be reinforced by the separate analysis of other aquatic communities and may be used then to set protective environmental standards after consideration of natural variability among lakes.

  6. Technical basis for inner container leak detection sensitivity goals in 3013 DE surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Berg, John M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-11

    Helium leak checking of 3013 inner container lids is under consideration for addition to DE Surveillance tasks as an improved means to detect any through-wall flaws that may have formed during storage. This white paper evaluates whether leak checking at DE could replace and improve upon the current method of comparing gas compositions and pressures within the inner and outer containers. We have used viscous and molecular flow equations in ANSI N14.5 to calculate what the measured standard helium leak rate would be for hypothetical leaks of three different sizes. For comparison, we have also calculated the effects on gas composition and pressure differences as a function of pre-DE storage time for the same three leak sizes, using molecular and viscous flow equations as well as diffusion equations to predict the relevant gas transport. For a hypothetical leak that would be measured at 1x10-7 std cc/sec, likely an achievable sensitivity using helium leak checking at DE, the calculations predict no measurable effect on pressure difference or gas composition as measured by DE gas analysis. We also calculate that it would take over 200 years for water vapor to diffuse through a 10-7 std cc/sec leak enough to raise the RH outer container to half the RH value in the inner container. A leak 100 times larger, which would be measured at 1x10-5 std cc/sec, the same water vapor diffusion would take at least 14 years. Our conclusion is that helium leak checking will be useful even at a sensitivity of 1x10-5 std cc/sec, and a significant improvement over current DE methods at a sensitivity of 1x10-7 std cc/sec.

  7. 29 CFR 99.100 - Purpose.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Purpose. 99.100 Section 99.100 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS General § 99.100 Purpose. This part sets forth standards for obtaining consistency and uniformity among Federal agencies for the...

  8. An electric field induced in the retina and brain at threshold magnetic flux density causing magnetophosphenes

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Akimasa; Takano, Yukinori; Fujiwara, Osamu [Nagoya Institute of Technology, Department of Computer Science and Engineering (Japan); Dovan, Thanh [SP AusNet, Division of Network Strategy and Development (Australia); Kavet, Robert, E-mail: ahirata@nitech.ac.jp [Electric Power Research Institute, Palo Alto, CA (United States)

    2011-07-07

    For magnetic field exposures at extremely low frequencies, the electrostimulatory response with the lowest threshold is the magnetophosphene, a response that corresponds to an adult exposed to a 20 Hz magnetic field of nominally 8.14 mT. In the IEEE standard C95.6 (2002), the corresponding in situ field in the retinal locus of an adult-sized ellipsoidal was calculated to be 53 mV m{sup -1}. However, the associated dose in the retina and brain at a high level of resolution in anatomically correct human models is incompletely characterized. Furthermore, the dose maxima in tissue computed with voxel human models are prone to staircasing errors, particularly for the low-frequency dosimetry. In the analyses presented in this paper, analytical and quasi-static finite-difference time-domain (FDTD) solutions were first compared for a three-layer sphere exposed to a uniform 50 Hz magnetic field. Staircasing errors in the FDTD results were observed at the tissue interface, and were greatest at the skin-air boundary. The 99th percentile value was within 3% of the analytic maximum, depending on model resolution, and thus may be considered a close approximation of the analytic maximum. For the adult anatomical model, TARO, exposed to a uniform magnetic field, the differences in the 99th percentile value of in situ electric fields for 2 mm and 1 mm voxel models were at most several per cent. For various human models exposed at the magnetophosphene threshold at three orthogonal field orientations, the in situ electric field in the brain was between 10% and 70% greater than the analytical IEEE threshold of 53 mV m{sup -1}, and in the retina was lower by roughly 50% for two horizontal orientations (anterior-posterior and lateral), and greater by about 15% for a vertically oriented field. Considering a reduction factor or safety factors of several folds applied to electrostimulatory thresholds, the 99th percentile dose to a tissue calculated with voxel human models may be used as an

  9. An electric field induced in the retina and brain at threshold magnetic flux density causing magnetophosphenes

    International Nuclear Information System (INIS)

    Hirata, Akimasa; Takano, Yukinori; Fujiwara, Osamu; Dovan, Thanh; Kavet, Robert

    2011-01-01

    For magnetic field exposures at extremely low frequencies, the electrostimulatory response with the lowest threshold is the magnetophosphene, a response that corresponds to an adult exposed to a 20 Hz magnetic field of nominally 8.14 mT. In the IEEE standard C95.6 (2002), the corresponding in situ field in the retinal locus of an adult-sized ellipsoidal was calculated to be 53 mV m -1 . However, the associated dose in the retina and brain at a high level of resolution in anatomically correct human models is incompletely characterized. Furthermore, the dose maxima in tissue computed with voxel human models are prone to staircasing errors, particularly for the low-frequency dosimetry. In the analyses presented in this paper, analytical and quasi-static finite-difference time-domain (FDTD) solutions were first compared for a three-layer sphere exposed to a uniform 50 Hz magnetic field. Staircasing errors in the FDTD results were observed at the tissue interface, and were greatest at the skin-air boundary. The 99th percentile value was within 3% of the analytic maximum, depending on model resolution, and thus may be considered a close approximation of the analytic maximum. For the adult anatomical model, TARO, exposed to a uniform magnetic field, the differences in the 99th percentile value of in situ electric fields for 2 mm and 1 mm voxel models were at most several per cent. For various human models exposed at the magnetophosphene threshold at three orthogonal field orientations, the in situ electric field in the brain was between 10% and 70% greater than the analytical IEEE threshold of 53 mV m -1 , and in the retina was lower by roughly 50% for two horizontal orientations (anterior-posterior and lateral), and greater by about 15% for a vertically oriented field. Considering a reduction factor or safety factors of several folds applied to electrostimulatory thresholds, the 99th percentile dose to a tissue calculated with voxel human models may be used as an

  10. 7 CFR 27.99 - Values; expression.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Values; expression. 27.99 Section 27.99 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... CLASSIFICATION UNDER COTTON FUTURES LEGISLATION Regulations Price Quotations and Differences § 27.99 Values...

  11. Comparison between intensity- duration thresholds and cumulative rainfall thresholds for the forecasting of landslide

    Science.gov (United States)

    Lagomarsino, Daniela; Rosi, Ascanio; Rossi, Guglielmo; Segoni, Samuele; Catani, Filippo

    2014-05-01

    This work makes a quantitative comparison between the results of landslide forecasting obtained using two different rainfall threshold models, one using intensity-duration thresholds and the other based on cumulative rainfall thresholds in an area of northern Tuscany of 116 km2. The first methodology identifies rainfall intensity-duration thresholds by means a software called MaCumBA (Massive CUMulative Brisk Analyzer) that analyzes rain-gauge records, extracts the intensities (I) and durations (D) of the rainstorms associated with the initiation of landslides, plots these values on a diagram, and identifies thresholds that define the lower bounds of the I-D values. A back analysis using data from past events can be used to identify the threshold conditions associated with the least amount of false alarms. The second method (SIGMA) is based on the hypothesis that anomalous or extreme values of rainfall are responsible for landslide triggering: the statistical distribution of the rainfall series is analyzed, and multiples of the standard deviation (σ) are used as thresholds to discriminate between ordinary and extraordinary rainfall events. The name of the model, SIGMA, reflects the central role of the standard deviations in the proposed methodology. The definition of intensity-duration rainfall thresholds requires the combined use of rainfall measurements and an inventory of dated landslides, whereas SIGMA model can be implemented using only rainfall data. These two methodologies were applied in an area of 116 km2 where a database of 1200 landslides was available for the period 2000-2012. The results obtained are compared and discussed. Although several examples of visual comparisons between different intensity-duration rainfall thresholds are reported in the international literature, a quantitative comparison between thresholds obtained in the same area using different techniques and approaches is a relatively undebated research topic.

  12. A novel electrochemical technique for the production of clinical grade 99mTc using (n, γ)99Mo

    International Nuclear Information System (INIS)

    Chakravarty, Rubel; Dash, Ashutosh; Venkatesh, Meera

    2010-01-01

    Introduction: In order to meet the growing demand for 99m Tc and to reduce the reliance on fission-produced 99 Mo, an electrochemical pathway for accessing 99m Tc through the (n, γ) 99 Mo was explored as a back-up measure and to supplement 99m Tc supply for radiopharmaceuticals application. Methods: 99m Tc from an equilibrium mixture of 99 Mo/ 99m Tc was selectively deposited on a platinum cathode in an electrochemical cell by applying optimal voltage and stripped back again into the 0.9% saline solution. The radiochemical and radionuclidic purity of the product were determined using standard techniques. 99m Tc thus obtained was used for labeling standard ligands such as dimercaptosuccinic acid (DMSA) and ethylene dicysteine (EC), to ascertain the usability. Results: Selective deposition of 99m Tc on the platinum electrode was achieved at a potential of 5 V over a period of 1 h in NaOH electrobath. The overall yield of 99m Tc was >90%, with >99.99% radionuclidic purity and >99% radiochemical purity. The performance of the generator remained consistent over a period of 10 days. The compatibility of the product in the preparation of 99m Tc-labeled formulations such as 99m Tc-DMSA and 99m Tc-EC was found to be satisfactory in terms of high labeling yields (>98%). Conclusion: A novel and attractive method has been developed to obtain highly concentrated 99m Tc, without using fission-produced 99 Mo.

  13. Sensitivity and Specificity of Swedish Interactive Threshold Algorithm and Standard Full Threshold Perimetry in Primary Open-angle Glaucoma.

    Science.gov (United States)

    Bamdad, Shahram; Beigi, Vahid; Sedaghat, Mohammad Reza

    2017-01-01

    Perimetry is one of the mainstays in glaucoma diagnosis and treatment. Various strategies offer different accuracies in glaucoma testing. Our aim was to determine and compare the diagnostic sensitivity and specificity of Swedish Interactive Threshold Algorithm (SITA) Fast and Standard Full Threshold (SFT) strategies of the Humphrey Field Analyzer (HFA) in identifying patients with visual field defect in glaucoma disease. This prospective observational case series study was conducted in a university-based eye hospital. A total of 37 eyes of 20 patients with glaucoma were evaluated using the central 30-2 program and both the SITA Fast and SFT strategies. Both strategies were performed for each strategy in each session and for four times in a 2-week period. Data were analyzed using the Student's t-test, analysis of variance, and chi-square test. The SITA Fast and SFT strategies had similar sensitivity of 93.3%. The specificity of SITA Fast and SFT strategies was 57.4% and 71.4% respectively. The mean duration of SFT tests was 14.6 minutes, and that of SITA Fast tests was 5.45 minutes (a statistically significant 62.5% reduction). In gray scale plots, visual field defect was less deep in SITA Fast than in SFT; however, more points had significant defect (p 0.5% and p deviation plots in SITA Fast than in SFT; these differences were not clinically significant. In conclusion, the SITA Fast strategy showed higher sensitivity for detection of glaucoma compared to the SFT strategy, yet with reduced specificity; however, the shorter test duration makes it a more acceptable choice in many clinical situations, especially for children, elderly, and those with musculoskeletal diseases.

  14. Standardization of a method to calculate absolute renal uptake of 99m Tc-DMSA in children

    International Nuclear Information System (INIS)

    Ono, Carla Rachel; Sapienza, Marcelo Tatit; Watanabe, Tomoco; Costa, Paulo Luiz Aguirre; Okamoto, Miriam Roseli Yoshie; Garcez, Alexandre Teles; Buchpiguel, Carlos Alberto; Machado, Beatriz Marcondes; Machado, Marcia Melo Campos; Liberato Junior, Waldyr de Paula

    2006-01-01

    Objective:To standardize a method and determine normal values for absolute renal uptake of 99m Tc-DMSA in children with normal creatinine clearance. Materials and methods: Twenty-two children (between 7 months and 10 years of age; mean 4.5 years) without clinical evidence of renal disease were studied using 99m Tc-DMSA scintigraphy. Eighteen had normal renal ultrasonography, micturating urethrocystography, creatinine clearance and visual interpretation of the scintigraphy with 99m Tc-DMSA. Four children were excluded, one with incomplete creatinine clearance and three due to reduction in the creatinine clearance. Absolute renal uptake of 99m Tc-DMSA (DMSA-Abs) was expressed as the fraction of the administered dose retained by each kidney six hours after administration of the radiopharmaceutical. Results: DMSA-Abs was 21.8 +- 3.2% for the right kidney and 23.1 +-3.3% for the left kidney. There was no correlation between renal uptake and the age groups studied, although there was a tendency to an increase in the creatinine clearance with age. Conclusion: Normal values of DMSA-Abs can be used as an additional parameter for the initial diagnostic evaluation and during follow-up of renal diseases, mainly when bilateral impairment of renal function is suspected or in a patient with a single functioning kidney (in which renal differential function is of limited value). (author)

  15. Characterization of plutonium-containing materials and storage canisters

    International Nuclear Information System (INIS)

    Mason, R.E.

    1997-01-01

    Throughout the weapons complex, plutonium materials are stored in various containers. Some plutonium has been stored for 20 yr or more. The physical and chemical properties of the plutonium material and the containers that hold it are often not well characterized. The U.S. Department of Energy (DOE) 3013 standard sets criteria to which stored material must conform. The 3013 standard regulates materials that hold 50% or greater plutonium, and the other 50% is not specified and is usually unknown. The Materials Identification and Surveillance project is tasked to characterize representative materials and begin to characterize the other 50% and to show that materials can be brought into 3013 criteria conformance through thermal treatments

  16. Residual Stresses and Other Properties of Teardrops

    Energy Technology Data Exchange (ETDEWEB)

    Stroud, Mary Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Veirs, Douglas Kirk [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Berg, John M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Hill, Mary Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rios, Daniel [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Duque, Juan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-26

    The Department of Energy’s 3013 Standard for packaging plutonium-bearing materials for storage up to fifty years specifies a minimum of two individually welded, nested containers herein referred to as the 3013 outer and the 3013 inner.1 Stress corrosion cracking (SCC) is a potential failure mechanism for 3013 inner containers.2,3 The bagless transfer container (BTC), a 3013 inner container used by Hanford and Savanna River Site (SRS) made from 304L stainless steel (SS), poses the greatest concern for SCC.4,5 The Surveillance and Monitoring Program (SMP) use stressed metal samples known as teardrops as screening tools in SCC studies to evaluate factors that could result in cracks in the 3013 containers.6,7 This report provides background information on the teardrops used in the Los Alamos National Laboratory (LANL) SMP studies including method of construction, composition and variability. In addition, the report discusses measurements of residual stresses in teardrops and compares the results with residual stresses in BTCs reported previously.4 Factors affecting residual stresses, including teardrop dimensions and surface finish, are also discussed.

  17. Waste management plan for inactive LLLW tanks 3001-B, 3004-B, 3013, and T-30 at Oak Ridge National Laboratory, Oak Ridge, Tennessee. Environmental Restoration Program

    International Nuclear Information System (INIS)

    1995-07-01

    This Project Waste Management Plan identifies the waste that is expected to be generated in connection with the removal and disposition of inactive liquid low-level radioactive waste tanks 3001-B, 3004-B, and T-30, and grouting of tank 3013 at the Oak Ridge National Laboratory and the isolation of these tanks' associated piping systems. The plan also identifies the organization, responsibilities, and administrative controls that will be followed to ensure proper handling of the waste

  18. Porcine skin visible lesion thresholds for near-infrared lasers including modeling at two pulse durations and spot sizes.

    Science.gov (United States)

    Cain, C P; Polhamus, G D; Roach, W P; Stolarski, D J; Schuster, K J; Stockton, K L; Rockwell, B A; Chen, Bo; Welch, A J

    2006-01-01

    With the advent of such systems as the airborne laser and advanced tactical laser, high-energy lasers that use 1315-nm wavelengths in the near-infrared band will soon present a new laser safety challenge to armed forces and civilian populations. Experiments in nonhuman primates using this wavelength have demonstrated a range of ocular injuries, including corneal, lenticular, and retinal lesions as a function of pulse duration. American National Standards Institute (ANSI) laser safety standards have traditionally been based on experimental data, and there is scant data for this wavelength. We are reporting minimum visible lesion (MVL) threshold measurements using a porcine skin model for two different pulse durations and spot sizes for this wavelength. We also compare our measurements to results from our model based on the heat transfer equation and rate process equation, together with actual temperature measurements on the skin surface using a high-speed infrared camera. Our MVL-ED50 thresholds for long pulses (350 micros) at 24-h postexposure are measured to be 99 and 83 J cm(-2) for spot sizes of 0.7 and 1.3 mm diam, respectively. Q-switched laser pulses of 50 ns have a lower threshold of 11 J cm(-2) for a 5-mm-diam top-hat laser pulse.

  19. REPORT ON THE MODELING OF THE LARGE MIS CANS

    International Nuclear Information System (INIS)

    MOODY, E.; LYMAN, J.; VEIRS, K.

    2000-01-01

    Changes in gas composition and gas pressure for closed systems containing plutonium dioxide and water are studied using a model that incorporates both radiolysis and chemical reactions. The model is used to investigate the behavior of material stored in storage containers conforming to DOE-STD-3013-99 storage standard. Scaling of the container to allow use of smaller amounts of nuclear material in experiments designed to bound the behavior of all material destined for long-term storage is studied. It is found that the container volume must be scaled along with the amount of material to achieve applicable results

  20. Preparation and Characterization of a Master Blend of Plutonium Oxide for the 3013 Large Scale Shelf-Life Surveillance Project

    Energy Technology Data Exchange (ETDEWEB)

    Gillispie, Obie William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Worl, Laura Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Veirs, Douglas Kirk [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stroud, Mary Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Narlesky, Joshua Edward [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Berg, John M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Kelly, Elizabeth J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Padilla, Dennis D. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bender, Beverly [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lopez, Annabelle S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Martinex, Max A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Trujillo, Leonardo A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wilson, Edward L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-04-10

    A mixture of chlorine-containing, impure plutonium oxides has been produced and has been given the name Master Blend. This large quantity of well-characterized chlorinecontaining material is available for use in the Integrated Surveillance and Monitoring Program for shelf-life experiments. It is intended to be representative of materials packaged to meet DOE-STD-3013.1 The Master Blend contains a mixture of items produced in Los Alamos National Laboratory’s (LANL) electro-refining pyrochemical process in the late 1990s. Twenty items were crushed and sieved, calcined to 800ºC for four hours, and blended multiple times. This process resulted in four batches of Master Blend. Calorimetry and density data on material from the four batches indicate homogeneity.

  1. Gas Generation from Actinide Oxide Materials

    International Nuclear Information System (INIS)

    Bailey, George; Bluhm, Elizabeth; Lyman, John; Mason, Richard; Paffett, Mark; Polansky, Gary; Roberson, G. D.; Sherman, Martin; Veirs, Kirk; Worl, Laura

    2000-01-01

    This document captures relevant work performed in support of stabilization, packaging, and long term storage of plutonium metals and oxides. It concentrates on the issue of gas generation with specific emphasis on gas pressure and composition. Even more specifically, it summarizes the basis for asserting that materials loaded into a 3013 container according to the requirements of the 3013 Standard (DOE-STD-3013-2000) cannot exceed the container design pressure within the time frames or environmental conditions of either storage or transportation. Presently, materials stabilized and packaged according to the 3013 Standard are to be transported in certified packages (the certification process for the 9975 and the SAFKEG has yet to be completed) that do not rely on the containment capabilities of the 3013 container. Even though no reliance is placed on that container, this document shows that it is highly likely that the containment function will be maintained not only in storage but also during transportation, including hypothetical accident conditions. Further, this document, by summarizing materials-related data on gas generation, can point those involved in preparing Safety Analysis Reports for Packages (SARPs) to additional information needed to assess the ability of the primary containment vessel to contain the contents and any reaction products that might reasonably be produced by the contents

  2. Gas Generation from Actinide Oxide Materials

    Energy Technology Data Exchange (ETDEWEB)

    George Bailey; Elizabeth Bluhm; John Lyman; Richard Mason; Mark Paffett; Gary Polansky; G. D. Roberson; Martin Sherman; Kirk Veirs; Laura Worl

    2000-12-01

    This document captures relevant work performed in support of stabilization, packaging, and long term storage of plutonium metals and oxides. It concentrates on the issue of gas generation with specific emphasis on gas pressure and composition. Even more specifically, it summarizes the basis for asserting that materials loaded into a 3013 container according to the requirements of the 3013 Standard (DOE-STD-3013-2000) cannot exceed the container design pressure within the time frames or environmental conditions of either storage or transportation. Presently, materials stabilized and packaged according to the 3013 Standard are to be transported in certified packages (the certification process for the 9975 and the SAFKEG has yet to be completed) that do not rely on the containment capabilities of the 3013 container. Even though no reliance is placed on that container, this document shows that it is highly likely that the containment function will be maintained not only in storage but also during transportation, including hypothetical accident conditions. Further, this document, by summarizing materials-related data on gas generation, can point those involved in preparing Safety Analysis Reports for Packages (SARPs) to additional information needed to assess the ability of the primary containment vessel to contain the contents and any reaction products that might reasonably be produced by the contents.

  3. Small-threshold behaviour of two-loop self-energy diagrams: two-particle thresholds

    International Nuclear Information System (INIS)

    Berends, F.A.; Davydychev, A.I.; Moskovskij Gosudarstvennyj Univ., Moscow; Smirnov, V.A.; Moskovskij Gosudarstvennyj Univ., Moscow

    1996-01-01

    The behaviour of two-loop two-point diagrams at non-zero thresholds corresponding to two-particle cuts is analyzed. The masses involved in a cut and the external momentum are assumed to be small as compared to some of the other masses of the diagram. By employing general formulae of asymptotic expansions of Feynman diagrams in momenta and masses, we construct an algorithm to derive analytic approximations to the diagrams. In such a way, we calculate several first coefficients of the expansion. Since no conditions on relative values of the small masses and the external momentum are imposed, the threshold irregularities are described analytically. Numerical examples, using diagrams occurring in the standard model, illustrate the convergence of the expansion below the first large threshold. (orig.)

  4. Dynamic multiple thresholding breast boundary detection algorithm for mammograms

    International Nuclear Information System (INIS)

    Wu, Yi-Ta; Zhou Chuan; Chan, Heang-Ping; Paramagul, Chintana; Hadjiiski, Lubomir M.; Daly, Caroline Plowden; Douglas, Julie A.; Zhang Yiheng; Sahiner, Berkman; Shi Jiazheng; Wei Jun

    2010-01-01

    Purpose: Automated detection of breast boundary is one of the fundamental steps for computer-aided analysis of mammograms. In this study, the authors developed a new dynamic multiple thresholding based breast boundary (MTBB) detection method for digitized mammograms. Methods: A large data set of 716 screen-film mammograms (442 CC view and 274 MLO view) obtained from consecutive cases of an Institutional Review Board approved project were used. An experienced breast radiologist manually traced the breast boundary on each digitized image using a graphical interface to provide a reference standard. The initial breast boundary (MTBB-Initial) was obtained by dynamically adapting the threshold to the gray level range in local regions of the breast periphery. The initial breast boundary was then refined by using gradient information from horizontal and vertical Sobel filtering to obtain the final breast boundary (MTBB-Final). The accuracy of the breast boundary detection algorithm was evaluated by comparison with the reference standard using three performance metrics: The Hausdorff distance (HDist), the average minimum Euclidean distance (AMinDist), and the area overlap measure (AOM). Results: In comparison with the authors' previously developed gradient-based breast boundary (GBB) algorithm, it was found that 68%, 85%, and 94% of images had HDist errors less than 6 pixels (4.8 mm) for GBB, MTBB-Initial, and MTBB-Final, respectively. 89%, 90%, and 96% of images had AMinDist errors less than 1.5 pixels (1.2 mm) for GBB, MTBB-Initial, and MTBB-Final, respectively. 96%, 98%, and 99% of images had AOM values larger than 0.9 for GBB, MTBB-Initial, and MTBB-Final, respectively. The improvement by the MTBB-Final method was statistically significant for all the evaluation measures by the Wilcoxon signed rank test (p<0.0001). Conclusions: The MTBB approach that combined dynamic multiple thresholding and gradient information provided better performance than the breast boundary

  5. 7 CFR 29.99 - Superseded certificate or sample.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Superseded certificate or sample. 29.99 Section 29.99 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards... REGULATIONS TOBACCO INSPECTION Regulations Appeal § 29.99 Superseded certificate or sample. When superseded...

  6. Smartphone threshold audiometry in underserved primary health-care contexts.

    Science.gov (United States)

    Sandström, Josefin; Swanepoel, De Wet; Carel Myburgh, Hermanus; Laurent, Claude

    2016-01-01

    To validate a calibrated smartphone-based hearing test in a sound booth environment and in primary health-care clinics. A repeated-measure within-subject study design was employed whereby air-conduction hearing thresholds determined by smartphone-based audiometry was compared to conventional audiometry in a sound booth and a primary health-care clinic environment. A total of 94 subjects (mean age 41 years ± 17.6 SD and range 18-88; 64% female) were assessed of whom 64 were tested in the sound booth and 30 within primary health-care clinics without a booth. In the sound booth 63.4% of conventional and smartphone thresholds indicated normal hearing (≤15 dBHL). Conventional thresholds exceeding 15 dB HL corresponded to smartphone thresholds within ≤10 dB in 80.6% of cases with an average threshold difference of -1.6 dB ± 9.9 SD. In primary health-care clinics 13.7% of conventional and smartphone thresholds indicated normal hearing (≤15 dBHL). Conventional thresholds exceeding 15 dBHL corresponded to smartphone thresholds within ≤10 dB in 92.9% of cases with an average threshold difference of -1.0 dB ± 7.1 SD. Accurate air-conduction audiometry can be conducted in a sound booth and without a sound booth in an underserved community health-care clinic using a smartphone.

  7. Investigation of olfactory function in normal volunteers by Tc-99m ECD Brain SPECT: Analysis using statistical parametric mapping

    International Nuclear Information System (INIS)

    Chung, Y.A.; Kim, S.H.; Park, Y.H.; Lee, S.Y.; Sohn, H.S.; Chung, S.K.

    2002-01-01

    The purpose of this study was to investigate olfactory function according to Tc-99m ECD uptake pattern in brain perfusion SPET of normal volunteer by means of statistical parametric mapping (SPM) analysis. The study population was 8 healthy volunteer subjects (M:F = 6:2, age range: 22-54 years, mean 34 years). We performed baseline brain perfusion SPET using 555 MBq of Tc-99m ECD in a silent dark room. Two hours later, we obtained brain perfusion SPET using 1110 MBq of Tc-99m ECD after 3% butanol solution under the same condition. All SPET images were spatially transformed to standard space smoothed and globally normalized. The differences between the baseline and odor-identification SPET images were statistically analyzed using SPM-99 software. The difference between two sets of brain perfusion SPET was considered significant at a threshold of uncorrected p values less than 0.01. SPM analysis revealed significant hyper-perfusion in both cingulated gyri, right middle temporal gyrus, right superior and inferior frontal gyri, right lingual gyrus and right fusiform gyrus on odor-identification SPET. This study shows that brain perfusion SPET can securely support other diagnostic techniques in the evaluation of olfactory function

  8. 42 CFR 9.9 - Facility staffing.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Facility staffing. 9.9 Section 9.9 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL PROVISIONS STANDARDS OF CARE FOR... Biosafety Officer must have experience in developing and monitoring biohazards and dealing with biosafety...

  9. ENTRIA workshop. Determine threshold values in radiation protection

    International Nuclear Information System (INIS)

    Diener, Lisa

    2015-01-01

    Threshold values affect our daily lives. Whether it concerns traffic or noise regulations, we all experience thresholds on a regular basis. But how are such values generated? The conference ''Determine Thres-hold Values in Radiation Protection'', taking place on January 27th 2015 in Braunschweig, focused on this question. The conference was undertaken in the context of the BMBF-funded interdisciplinary research project ''ENTRIA - Disposal Options for Radioactive Residues''. It aimed to stimulate a cross-disciplinary discussion. Spea-kers from different disciplinary backgrounds talked about topics like procedures of setting threshold values, standards for evaluating dosages, and public participation in the standardization of threshold values. Two major theses emerged: First, setting threshold values always requires considering contexts and protection targets. Second, existing uncertainties must be communicated in and with the public. Altogether, the conference offered lots of input and issues for discussion. In addition, it raised interesting and important questions for further and ongoing work in the research project ENTRIA.

  10. Maintenance Action Readiness Assessment Plan for Waste Area Grouping 1 inactive Tanks 3001-B, 3004-B, T-30, and 3013 at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1995-07-01

    This Readiness Assessment Plan has been prepared to document operational readiness for the maintenance action consisting of remediation of four inactive liquid low-level radioactive tanks in Waste Area Grouping 1 at Oak Ridge National Laboratory. The four tanks to be remediated are Tanks 3001-B, 3004-B, T-30, and 3013. Tanks 3001-B, 3004-B, and T-30 will be removed from the ground. Because of logistical issues associated with excavation and site access, Tank 3013 will be grouted in place and permanently closed. This project is being performed as a maintenance action rather than an action under the Comprehensive Environmental Response, Compensation, and Liability Act, because the risk to human health and environment is well below the US Environmental Protection Agency's level of concern. The decision to proceed as a maintenance action was documented by an interim action proposed plan, which is included in the administrative record. A Readiness Assessment Team has been assembled to review the criteria deemed necessary to conduct the remediation tasks. These criteria include approval of all plans, acquisition of needed equipment, completion of personnel training, and coordination with plant health and safety personnel. Once the criteria have been met and documented, the task will begin. The readiness assessment is expected to be completed by late July 1995, and the task will begin thereafter

  11. Evaluation of '99Mo presence in eluates of 99mTc used in nuclear medicine

    International Nuclear Information System (INIS)

    Ribeiro, Bianca da Silva

    2010-01-01

    Tc-99m is used for diagnostic imaging in nuclear medicine through SPECT technique. It is obtained by the elution of 99 Mo/ 99m Tc generators. During the elution process 99 Mo can be extracted becoming a radionuclidic impurity. One of the quality parameters of the eluate is the radionuclidic purity, MBT (molybdenum break through), defined as the ratio between 99 Mo and 99m Tc activities in the eluate. The North-American and European pharmacopoeias restrict the 99 Mo content, respectively, in 0.015 e 0.1% and, according to the International Atomic Energy Agency (IAEA), the activity ratio at the moment of administration of the radiopharmaceutical to the patient, should not exceed 0.015%. In Brazil, the control of such parameter is not obliged in official regulations. Thus, the objective of this work is to evaluate the occurrence of 99 Mo in 99m Tc eluates. It was initially optimized a methodology to determine the activity of 99 Mo in eluate samples. Efficiency curves were obtained for a NaI (Tl) 8'' x 4'' scintillation detector installed at the In Vivo Monitoring Laboratory (LABMIV-IRD). The methodology has been validated through the measurement of a 99 Mo standard liquid source calibrated at the National Metrology Laboratory for Ionizing Radiation (LNMRI-IRD). The samples analyzed in this work were gently supplied by 5 Nuclear Medicine Clinics located in the city of Rio de Janeiro. The activities of 99 mTc and 99 Mo in those samples have been measured respectively at the clinics and at the LABMIV. By applying a standardized methodology, the ration between the activities were calculated. The results show that 147 out of 174 samples presented 99 Mo activities above the minimum detectable activity of the technique. On the other hand, only 2 out of 147 samples surpassed the MBT limit suggested by the IAEA and have been detected in samples eluted from generators of 750 mCi. In one of the samples, eluted from a generator of 1000 mCi, the calculated MBT value was very close

  12. A light-powered sub-threshold microprocessor

    Energy Technology Data Exchange (ETDEWEB)

    Liu Ming; Chen Hong; Zhang Chun; Li Changmeng; Wang Zhihua, E-mail: lium02@mails.tsinghua.edu.cn [Institute of Microelectronics, Tsinghua University, Beijing 100084 (China)

    2010-11-15

    This paper presents an 8-bit sub-threshold microprocessor which can be powered by an integrated photosensitive diode. With a custom designed sub-threshold standard cell library and 1 kbit sub-threshold SRAM design, the leakage power of 58 nW, dynamic power of 385 nW - 165 kHz, EDP 13 pJ/inst and the operating voltage of 350 mV are achieved. Under a light of about 150 kLux, the microprocessor can run at a rate of up to 500 kHz. The microprocessor can be used for wireless-sensor-network nodes.

  13. Administered activity of Tc-99m MDP for bone scintigraphy, standard or individual dosage?

    International Nuclear Information System (INIS)

    Vestergren, E.; Gretarsdottir, J.; Jacobsson, L.

    2002-01-01

    Background and Aim: Adult patients are generally, irrespective of size, given the same amount of activity for a certain type of nuclear medicine examination, a standard dosage. Identical image quality is essential when comparing different patient studies. The aim of this study is to evaluate different dosage methods for Tc-99m-MDP bone scintigraphy and to investigate whether individual dosage will decrease the variations in image quality between different patients. Material and Methods: 100 consecutive adult patients (aged between 40 and 89 years) undergoing whole body bone scintigraphy were studied. Eight patients were excluded from the study because of abnormal high uptake in the areas of interest. The patient weight and height were registered. The activity in the syringes was measured before and after the injection of about 600 MBq Tc-99m MDP. Scanning was performed, with a dual head gamma camera (Maxxus or Millennium VG, General Electric) equipped with a high-resolution collimator, at approximately 4 hours (mean 3.8 h) post-injection. Regions of interest (ROI) were drawn over the lumbar spine (posterior view), the right femur (anterior view) and also soft tissue background regions for each area. The total counts, maximum counts/pixel and number of pixels in the ROIs were registered. The maximum number of counts/pixel (background-subtracted), SPINEmax and FEMURmax were chosen as the image quality parameters. For each patient, SPINEmax and FEMURmax where recalculated to the number that would have been obtained with standard dosage (exactly 600 MBq), and dosage proportional to body weight, body surface area and body height. All values were corrected to a scanning time 3.8 h after injection. Results: Both with a standard activity dosage and a dosage proportional to body height, SPINEmax decreases with increasing body weight. Dosage proportional to body weight gives increasing values of SPINEmax with increasing body weight. Dosage proportional to body surface area

  14. Gas generation over plutonium oxides in the 94-1 shelf-life surveillance program

    International Nuclear Information System (INIS)

    Berg, J.M.; Harradine, D.M.; Hill, D.D.; McFarlan, James T.; Padilla, D.D.; Prenger, F. Coyne; Veirs, D.K.; Worl, L.A.

    2002-01-01

    The Department of Energy (DOE) is embarking upon a program to store large quantities of plutonium-bearing materials for up to fifty years. The Los Alamos National Laboratory Shelf Life Project was established to bound the behavior of plutonium-bearing material meeting the DOE 3013 Standard. The shelf life study monitors temperature, pressure and gas composition over oxide materials in a limited number of large-scale 3013 inner containers and in many small-scale containers. For the large-scale study, baseline plutonium oxides, oxides exposed to high-humidity atmospheres, and oxides containing chloride salt impurities are planned. The first large-scale container represents a baseline and contains dry plutonium oxide prepared according to the 3013 Standard. This container has been observed for pressure, temperature and gas compositional changes for less than a year. Results indicate that no detectable changes in pressure and gas composition are observed.

  15. Biodistribution of 99Mo in rats

    International Nuclear Information System (INIS)

    Souza, Raphael Sancho Sisley de; Ribeiro, Bianca da Silva; Dantas, Ana Leticia Almeida; Dantas, Bernardo Maranhao; Bernardo Filho, Mario

    2009-01-01

    The modification of 99 Mo standard metabolism in the presence of MDP would alter the dosimetry of this radionuclide in nuclear medicine patients. Therefore, the objective of this work is to evaluate the influence of MDP in the biodistribution of 99 Mo. Wistar rats were divided in two groups of six animals, being inoculated respectively 99 Molibdate and 99 Mo+MDP via plex ocular. The biodistribution study was carried out after 10 and 120 minutes respectively. The organs were counted with a NaI(Tl) detector. The uptake values did not present significant differences among the groups. An in vitro study through planar chromatography was carried out to determine the affinity between molybdenum and MDP. The results show that 99 Mo has low affinity both to propanone and NaCl-0.9% solution. However, 99 Mo in the presence of MDP presented affinity to NaCl-0.9% solution and low affinity to propanone suggesting that 99 Mo was bound to MDP under the conditions of the experiment. (author)

  16. Reference hearing threshold levels for short duration signals

    DEFF Research Database (Denmark)

    Poulsen, Torben; Legarth, Søren Vase

    2008-01-01

    for the determination of reference hearing threshold levels. The results are given as peak-to-peak equivalent threshold sound pressure levels (peETSPL). The results are in good agreement with other sparse results from literature and are part of the basis for the ISO 389-6 standard from 2007....

  17. Time and Temperature Test Results for PFP Thermal Stabilization Furnaces

    International Nuclear Information System (INIS)

    COMPTON, J.A.

    2000-01-01

    The national standard for plutonium storage acceptability (standard DOE-STD-3013-99, generally known as ''the 3013 standard'') has been revised to clarify the requirement for processes that will produce acceptable storage materials. The 3013 standard (Reference 1) now states that ''Oxides shall be stabilized by heating the material in an oxidizing atmosphere to a Material Temperature of at least 950 C (1742 F) for not less than 2 hours.'' The process currently in use for producing stable oxides for storage at the Plutonium Finishing Plant (PFP) heats a furnace atmosphere to 1000 C and holds it there for 2 hours. The temperature of the material being stabilized is not measured directly during this process. The Plutonium Process Support Laboratories (PPSL) were requested to demonstrate that the process currently in use at PFP is an acceptable method of producing stable plutonium dioxide consistently. A spare furnace identical to the production furnaces was set up and tested under varying conditions with non-radioactive surrogate materials. Reference 2 was issued to guide the testing program. The process currently in use at the PFP for stabilizing plutonium-bearing powders was shown to heat all the material in the furnace to at least 950 C for at least 2 hours. The current process will work for (1) relatively pure plutonium dioxide, (2) dioxide powders mixed with up to 20 weight percent magnesium oxide, and (3) dioxide powders with up to 11 weight percent magnesium oxide and 20 weight percent magnesium nitrate hexahydrate. Time and temperature data were also consistent with a successful demonstration for a mixture containing 10 weight percent each of sodium and potassium chloride; however, the molten chloride salts destroyed the thermocouples in the powder and temperature data were unavailable for part of that run. These results assume that the current operating limits of no more than 2500 grams per furnace charge and a powder height of no more than 1.5 inches remain

  18. Possible combustion hazards in 3013 plutonium waste container

    International Nuclear Information System (INIS)

    Sherman, M.P.

    1999-01-01

    Are there combustion hazards in plutonium-contaminated waste containers caused by combustible gas generation? Current gas generation models in which the only reaction considered is radiolysis must inevitably predict eventual complete dissociation of any water present into hydrogen and oxygen. Waste prepared for the 3013 container should be less subject to this problem because organic material and most of the absorbed water should have been removed. Depending on the waste form, moisture content, organic content, temperature, and container material, the pressure rise due to gas generation will be bounded by backreactions, recombination of the hydrogen and oxygen, absorption of the oxygen by plutonium oxide, and possibly other chemical reactions. Examination of a variety of food pack waste containers at Los Alamos National Laboratory (LANL) has shown little pressure rise, indeed often subatmospheric pressures. In a few cases large hydrogen concentrations up to 47% mole fraction were observed, but with negligible oxygen content. The only fuel seen in significant quantities was H 2 and, in one case, CO; the only oxidizer seen in significant quantities was O 2 . Considerable work on measuring gas generation is being done at Westinghouse Savannah River Company and LANL. In a mixture of H 2 , O 2 , and other diluent gases, if the hydrogen concentration is below the value at the lean flammability limit, or if the oxygen concentration is below that at the rich flammability limit, a flame will not propagate from an ignition source. Assuming H 2 is the only fuel present in significant quantities, a mixture leaner than the lean limit will get only leaner if mixed with air and is therefore no combustion hazard. However, when a mixture containing large amounts of H 2 is nonflammable because there is insufficient O 2 , there is a hazard. If the mixture should leak into a volume containing O 2 , or the container is opened into the surrounding air, the mixture will pass through the

  19. {sup 99m}Tc-HMPAO and {sup 99m}Tc-ECD perform differently in typically hypoperfused areas in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Koulibaly, Pierre Malick [Nuclear Medicine Department, Centre Antoine Lacassagne, University of Nice-Sophia Antipolis (France); Laboratoire de Biophysique, Universite de Nice-Sophia Antipolis, UFR de Medecine, 28 Avenue de Valombrose, 06107, Nice Cedex 2 (France); Nobili, Flavio; Vitali, Paolo; Girtler, Nicola; Rodriguez, Guido [Clinical Neurophysiology, Department of Internal Medicine, University of Genoa (Italy); Migneco, Octave; Darcourt, Jacques [Nuclear Medicine Department, Centre Antoine Lacassagne, University of Nice-Sophia Antipolis (France); Robert, Philippe H. [Memory Center, Federation of Clinical Neuroscience, Centre Hospitalier Universitaire, University of Nice-Sophia Antipolis (France)

    2003-07-01

    Technetium-99m hexamethylpropylene amine oxime (HMPAO) and {sup 99m}Tc-N,N''-1,2-ethylene diylbis-l-cysteine diethyl ester dihydrochloride (ECD) yield significantly different images of cerebral perfusion owing to their particular pharmacokinetics. The aim of this study was to assess the topography, extension and statistical significance of these differences in Alzheimer's disease (AD). Sixty-four patients with mild to moderate AD were retrospectively selected by two European centres. Two series of patients, including 32 studied with {sup 99m}Tc-HMPAO single-photon emission tomography (SPET) and 32 studied with {sup 99m}Tc-ECD SPET, were matched for sex, age ({+-}3 years) and severity of cognitive impairment as assessed by the Mini-Mental State Examination (MMSE) ({+-}2 points), following a case-control procedure. SPET data were processed using SPM99 software (uncorrected height threshold: P=0.001). {sup 99m}Tc-ECD SPET gave significantly higher uptake ratio values than {sup 99m}Tc-HMPAO SPET in several symmetrical clusters, including the right and left occipital cuneus, the left occipital and parietal precuneus, and the left superior and middle temporal gyri. {sup 99m}Tc-HMPAO SPET gave significantly higher uptake ratio values than ECD in two smaller clusters, including the hippocampus in both hemispheres. In AD, relative brain uptake of {sup 99m}Tc-HMPAO and {sup 99m}Tc-ECD is different in several brain regions, some of which are typically involved in AD, such as the precuneus and the hippocampus. These differences confirm the need for specific normal databases, but their impact on routine SPET reports in AD is not known and deserves an ad hoc investigation. (orig.)

  20. High-frequency (8 to 16 kHz) reference thresholds and intrasubject threshold variability relative to ototoxicity criteria using a Sennheiser HDA 200 earphone.

    Science.gov (United States)

    Frank, T

    2001-04-01

    The first purpose of this study was to determine high-frequency (8 to 16 kHz) thresholds for standardizing reference equivalent threshold sound pressure levels (RETSPLs) for a Sennheiser HDA 200 earphone. The second and perhaps more important purpose of this study was to determine whether repeated high-frequency thresholds using a Sennheiser HDA 200 earphone had a lower intrasubject threshold variability than the ASHA 1994 significant threshold shift criteria for ototoxicity. High-frequency thresholds (8 to 16 kHz) were obtained for 100 (50 male, 50 female) normally hearing (0.25 to 8 kHz) young adults (mean age of 21.2 yr) in four separate test sessions using a Sennheiser HDA 200 earphone. The mean and median high-frequency thresholds were similar for each test session and increased as frequency increased. At each frequency, the high-frequency thresholds were not significantly (p > 0.05) different for gender, test ear, or test session. The median thresholds at each frequency were similar to the 1998 interim ISO RETSPLs; however, large standard deviations and wide threshold distributions indicated very high intersubject threshold variability, especially at 14 and 16 kHz. Threshold repeatability was determined by finding the threshold differences between each possible test session comparison (N = 6). About 98% of all of the threshold differences were within a clinically acceptable range of +/-10 dB from 8 to 14 kHz. The threshold differences between each subject's second, third, and fourth minus their first test session were also found to determine whether intrasubject threshold variability was less than the ASHA 1994 criteria for determining a significant threshold shift due to ototoxicity. The results indicated a false-positive rate of 0% for a threshold shift > or = 20 dB at any frequency and a false-positive rate of 2% for a threshold shift >10 dB at two consecutive frequencies. This study verified that the output of high-frequency audiometers at 0 dB HL using

  1. Energy-Specific Optimization of Attenuation Thresholds for Low-Energy Virtual Monoenergetic Images in Renal Lesion Evaluation.

    Science.gov (United States)

    Patel, Bhavik N; Farjat, Alfredo; Schabel, Christoph; Duvnjak, Petar; Mileto, Achille; Ramirez-Giraldo, Juan Carlos; Marin, Daniele

    2018-05-01

    The purpose of this study was to determine in vitro and in vivo the optimal threshold for renal lesion vascularity at low-energy (40-60 keV) virtual monoenergetic imaging. A rod simulating unenhanced renal parenchymal attenuation (35 HU) was fitted with a syringe containing water. Three iodinated solutions (0.38, 0.57, and 0.76 mg I/mL) were inserted into another rod that simulated enhanced renal parenchyma (180 HU). Rods were inserted into cylindric phantoms of three different body sizes and scanned with single- and dual-energy MDCT. In addition, 102 patients (32 men, 70 women; mean age, 66.8 ± 12.9 [SD] years) with 112 renal lesions (67 nonvascular, 45 vascular) measuring 1.1-8.9 cm underwent single-energy unenhanced and contrast-enhanced dual-energy CT. Optimal threshold attenuation values that differentiated vascular from nonvascular lesions at 40-60 keV were determined. Mean optimal threshold values were 30.2 ± 3.6 (standard error), 20.9 ± 1.3, and 16.1 ± 1.0 HU in the phantom, and 35.9 ± 3.6, 25.4 ± 1.8, and 17.8 ± 1.8 HU in the patients at 40, 50, and 60 keV. Sensitivity and specificity for the thresholds did not change significantly between low-energy and 70-keV virtual monoenergetic imaging (sensitivity, 87-98%; specificity, 90-91%). The AUC from 40 to 70 keV was 0.96 (95% CI, 0.93-0.99) to 0.98 (95% CI, 0.95-1.00). Low-energy virtual monoenergetic imaging at energy-specific optimized attenuation thresholds can be used for reliable characterization of renal lesions.

  2. The standardization methods of radioactive sources (125I, 131I, 99mTc, and 18F) for calibrating nuclear medicine equipment in Indonesia

    International Nuclear Information System (INIS)

    Wurdiyanto, G; Candra, H

    2016-01-01

    The standardization of radioactive sources ( 125 I, 131 I, 99m Tc and 18 F) to calibrate the nuclear medicine equipment had been carried out in PTKMR-BATAN. This is necessary because the radioactive sources used in the field of nuclear medicine has a very short half-life in other that to obtain a quality measurement results require special treatment. Besides that, the use of nuclear medicine techniques in Indonesia develop rapidly. All the radioactive sources were prepared by gravimetric methods. Standardization of 125 I has been carried out by photon- photon coincidence methods, while the others have been carried out by gamma spectrometry methods. The standar sources are used to calibrate a Capintec CRC-7BT radionuclide calibrator. The results shows that calibration factor for Capintec CRC-7BT dose calibrator is 1,03; 1,02; 1,06; and 1,04 for 125 I, 131 I, 99m Tc and 18 F respectively, by about 5 to 6% of the expanded uncertainties. (paper)

  3. The standardization methods of radioactive sources (125I, 131I, 99mTc, and 18F) for calibrating nuclear medicine equipment in Indonesia

    Science.gov (United States)

    Wurdiyanto, G.; Candra, H.

    2016-03-01

    The standardization of radioactive sources (125I, 131I, 99mTc and 18F) to calibrate the nuclear medicine equipment had been carried out in PTKMR-BATAN. This is necessary because the radioactive sources used in the field of nuclear medicine has a very short half-life in other that to obtain a quality measurement results require special treatment. Besides that, the use of nuclear medicine techniques in Indonesia develop rapidly. All the radioactive sources were prepared by gravimetric methods. Standardization of 125I has been carried out by photon- photon coincidence methods, while the others have been carried out by gamma spectrometry methods. The standar sources are used to calibrate a Capintec CRC-7BT radionuclide calibrator. The results shows that calibration factor for Capintec CRC-7BT dose calibrator is 1,03; 1,02; 1,06; and 1,04 for 125I, 131I, 99mTc and 18F respectively, by about 5 to 6% of the expanded uncertainties.

  4. Molybdenum-99 supply: a global issue

    International Nuclear Information System (INIS)

    Cote, R.V.

    2011-01-01

    This article discusses the global supply of Molybdenum 99 used in nuclear medicine. Following a disruption in supplies of isotopes in the last few years, a Canadian expert panel assessed the most viable options for securing a sustainable supply of Technitium 99 over the medium to long term. The general recommendations were to strive for diversity and redundancy throughout the supply chain, leverage multi-use infrastructure, continue with international coordination and seek processing standardization within North America.

  5. 14 CFR 99.19-99.31 - [Reserved

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false [Reserved] 99.19-99.31 Section 99.19-99.31 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SECURITY CONTROL OF AIR TRAFFIC General §§ 99.19-99.31 [Reserved] ...

  6. A non-parametric framework for estimating threshold limit values

    Directory of Open Access Journals (Sweden)

    Ulm Kurt

    2005-11-01

    Full Text Available Abstract Background To estimate a threshold limit value for a compound known to have harmful health effects, an 'elbow' threshold model is usually applied. We are interested on non-parametric flexible alternatives. Methods We describe how a step function model fitted by isotonic regression can be used to estimate threshold limit values. This method returns a set of candidate locations, and we discuss two algorithms to select the threshold among them: the reduced isotonic regression and an algorithm considering the closed family of hypotheses. We assess the performance of these two alternative approaches under different scenarios in a simulation study. We illustrate the framework by analysing the data from a study conducted by the German Research Foundation aiming to set a threshold limit value in the exposure to total dust at workplace, as a causal agent for developing chronic bronchitis. Results In the paper we demonstrate the use and the properties of the proposed methodology along with the results from an application. The method appears to detect the threshold with satisfactory success. However, its performance can be compromised by the low power to reject the constant risk assumption when the true dose-response relationship is weak. Conclusion The estimation of thresholds based on isotonic framework is conceptually simple and sufficiently powerful. Given that in threshold value estimation context there is not a gold standard method, the proposed model provides a useful non-parametric alternative to the standard approaches and can corroborate or challenge their findings.

  7. The relationship of VOI threshold, volume and B/S on DISA images

    International Nuclear Information System (INIS)

    Song Liejing; Wang Mingming; Si Hongwei; Li Fei

    2011-01-01

    Objective: To explore the relationship of VOI threshold, Volume and B/S on DISA phantom images. Methods: Ten hollow spheres were placed in cylinder phantom. According to the B/S of 1 : 7, 1 : 5 and 1 : 4, 99m TcO 4- and 18 F-FDG was filled into the container and spheres simultaneously and separately. Images were acquired by DISA and SIDA protocol. Volume of interest (VOI) for each sphere was analyzed by threshold method and to fit expression individually for validating of the relationship. Results: The equation for the estimation of optimal threshold was as following Tm = d + c × Bm/(e + f × Vm) + b/Vm. In majority of data, the calculated threshold was in the 1% interval that optimal thresholds were really in. Those who were not in were at the lower or upper intervals. Conclusions: Both DISA and SIDA images, based o the relationship of VOI thresh- old. Volume and B/S and real volume, this method could accurately calculate optimal threshold with an error less than 1% for spheres whose volumes ranged from 3.3 to 30.8 ml. (authors)

  8. Standardization of a method to calculate absolute renal uptake of {sup 99m} Tc-DMSA in children; Padronizacao do metodo para calculo da captacao renal absoluta do {sup 99m}Tc-DMSA em criancas

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Carla Rachel; Sapienza, Marcelo Tatit; Watanabe, Tomoco; Costa, Paulo Luiz Aguirre; Okamoto, Miriam Roseli Yoshie; Garcez, Alexandre Teles; Buchpiguel, Carlos Alberto [Sao Paulo Univ., SP (Brazil). Hospital das Clinicas. Servico de Medicina Nuclear]. E-mail: crachelo@usp.br; Machado, Beatriz Marcondes; Machado, Marcia Melo Campos [Paulo Univ., SP (Brazil). Faculdade de Medicina. Hospital Universitario; Liberato Junior, Waldyr de Paula

    2006-01-15

    Objective:To standardize a method and determine normal values for absolute renal uptake of 99m Tc-DMSA in children with normal creatinine clearance. Materials and methods: Twenty-two children (between 7 months and 10 years of age; mean 4.5 years) without clinical evidence of renal disease were studied using 99m Tc-DMSA scintigraphy. Eighteen had normal renal ultrasonography, micturating urethrocystography, creatinine clearance and visual interpretation of the scintigraphy with 99m Tc-DMSA. Four children were excluded, one with incomplete creatinine clearance and three due to reduction in the creatinine clearance. Absolute renal uptake of 99m Tc-DMSA (DMSA-Abs) was expressed as the fraction of the administered dose retained by each kidney six hours after administration of the radiopharmaceutical. Results: DMSA-Abs was 21.8 +- 3.2% for the right kidney and 23.1 +-3.3% for the left kidney. There was no correlation between renal uptake and the age groups studied, although there was a tendency to an increase in the creatinine clearance with age. Conclusion: Normal values of DMSA-Abs can be used as an additional parameter for the initial diagnostic evaluation and during follow-up of renal diseases, mainly when bilateral impairment of renal function is suspected or in a patient with a single functioning kidney (in which renal differential function is of limited value). (author)

  9. Europe's Other Poverty Measures: Absolute Thresholds Underlying Social Assistance

    Science.gov (United States)

    Bavier, Richard

    2009-01-01

    The first thing many learn about international poverty measurement is that European nations apply a "relative" poverty threshold and that they also do a better job of reducing poverty. Unlike the European model, the "absolute" U.S. poverty threshold does not increase in real value when the nation's standard of living rises,…

  10. Social psychological approach to the problem of threshold

    International Nuclear Information System (INIS)

    Nakayachi, Kazuya

    1999-01-01

    This paper discusses the threshold of carcinogen risk from the viewpoint of social psychology. First, the results of a survey suggesting that renunciation of the Linear No-Threshold (LNT) hypothesis would have no influence on the public acceptance (PA) of nuclear power plants are reported. Second, the relationship between the adoption of the LNT hypothesis and the standardization of management for various risks are discussed. (author)

  11. Azygos Vein Lead Implantation For High Defibrillation Thresholds In Implantable Cardioverter Defibrillator Placement

    Directory of Open Access Journals (Sweden)

    Naga VA Kommuri

    2010-01-01

    Full Text Available Evaluation of defibrillation threshold is a standard of care during implantation of implantable cardioverter defibrillator. High defibrillation thresholds are often encountered and pose a challenge to electrophysiologists to improve the defibrillation threshold. We describe a case series where defibrillation thresholds were improved after implanting a defibrillation lead in the azygos vein.

  12. Improved Bat Algorithm Applied to Multilevel Image Thresholding

    Directory of Open Access Journals (Sweden)

    Adis Alihodzic

    2014-01-01

    Full Text Available Multilevel image thresholding is a very important image processing technique that is used as a basis for image segmentation and further higher level processing. However, the required computational time for exhaustive search grows exponentially with the number of desired thresholds. Swarm intelligence metaheuristics are well known as successful and efficient optimization methods for intractable problems. In this paper, we adjusted one of the latest swarm intelligence algorithms, the bat algorithm, for the multilevel image thresholding problem. The results of testing on standard benchmark images show that the bat algorithm is comparable with other state-of-the-art algorithms. We improved standard bat algorithm, where our modifications add some elements from the differential evolution and from the artificial bee colony algorithm. Our new proposed improved bat algorithm proved to be better than five other state-of-the-art algorithms, improving quality of results in all cases and significantly improving convergence speed.

  13. Study to improve the precision of calculation of split renal clearance by gamma camera method using 99mTc-MAG3

    International Nuclear Information System (INIS)

    Mimura, Hiroaki; Tomomitsu, Tatsushi; Yanagimoto, Shinichi

    1999-01-01

    Both fundamental and clinical studies were performed to improve the precision with which split renal clearance is calculated from the relation between renal clearance and the total renal uptake rate by using 99m Tc-MAG 3 , which is mainly excreted into the proximal renal tubules. In the fundamental study, the most suitable kidney phantom threshold values for the extracted renal outline were investigated with regard to size, radioactivity, depth of the kidney phantom, and radioactivity in the background. In the clinical study, suitable timing to obtain additional images for making the ROI and the standard point for calculation of renal uptake rate were investigated. The results indicated that, although suitable threshold values were distributed from 25% to 45%, differences in size, solution activity, and the position of the phantom or BG activity did not have significant effects. Comparing 1-3 min with 2-5 min as the time for additional images for ROI, we found that renal areas using the former time showed higher values, and the correlation coefficient of the regression formula improved significantly. Comparison of the timing for the start of data acquisition with the end of the arterial phase as a standard point of calculating renal uptake rate showed improvement in the latter. (author)

  14. Low-threshold conical microcavity dye lasers

    DEFF Research Database (Denmark)

    Grossmann, Tobias; Schleede, Simone; Hauser, Mario

    2010-01-01

    element simulations confirm that lasing occurs in whispering gallery modes which corresponds well to the measured multimode laser-emission. The effect of dye concentration on lasing threshold and lasing wavelength is investigated and can be explained using a standard dye laser model....

  15. Cyclotron Production of Technetium-99m

    Science.gov (United States)

    Gagnon, Katherine M.

    Technetium-99m (99mTc) has emerged as the most widely used radionuclide in medicine and is currently obtained from a 99Mo/ 99mTc generator system. At present, there are only a handful of ageing reactors worldwide capable of producing large quantities of the parent isotope, 99Mo, and owing to the ever growing shutdown periods for maintenance and repair of these ageing reactors, the reliable supply 99mTc has been compromised in recent years. With an interest in alternative strategies for producing this key medical isotope, this thesis focuses on several technical challenges related to the direct cyclotron production of 99mTc via the 100Mo(p,2n)99mTc reaction. In addition to evaluating the 100Mo(p,2n)99mTc and 100Mo(p,x)99Mo reactions, this work presented the first experimental evaluation of the 100Mo(p,2n) 99gTc excitation function in the range of 8-18 MeV. Thick target calculations suggested that large quantities of cyclotron-produced 99mTc may be possible. For example, a 6 hr irradiation at 500 μA with an energy window of 18→10 MeV is expected to yield 1.15 TBq of 99mTc. The level of coproduced 99gTc contaminant was found to be on par with the current 99Mo/99mTc generator standard eluted with a 24 hr frequency. Highly enriched 100Mo was required as the target material for 99mTc production and a process for recycling of this expensive material is presented. An 87% recovery yield is reported, including metallic target preparation, irradiation, 99mTc extraction, molybdate isolation, and finally hydrogen reduction to the metal. Further improvements are expected with additional optimization experiments. A method for forming structurally stable metallic molybdenum targets has also been developed. These targets are capable of withstanding more than a kilowatt of beam power and the reliable production and extraction of Curie quantities of 99mTc has been demonstrated. With the end-goal of using the cyclotron-produced 99mTc clinically, the quality of the cyclotron

  16. Minimizing Molybdenum 99 contamination in Technetium 99m Pertechnetate from the elution of 99Mo/ 99m Tc Generator

    International Nuclear Information System (INIS)

    Zakaria Ibrahim; Zulkifli Hashim; Bohari Yaacob

    2011-01-01

    Radioisotope Tc-99m is widely used for variety of nuclear medicine diagnostic procedures. For many commercial applications, it is prepared in a portable type generator. Nuclear Malaysia has been producing a dry type alumina chromatographic column generator utilizing fission Mo-99. This injectable Tc-99m must meet the British Pharmacopeia [1] product specification prior to be apply on patient. This paper provides a method to minimize the up to acceptable level Mo-99 in the final product. Purposely made pertechnetate contaminated with Mo-99 and re-eluate by using old generator. Excellent removal of Mo-99 impurity was achieved and more than 80 % of Tc-99m total activity was recovered. (author)

  17. Twelve automated thresholding methods for segmentation of PET images: a phantom study

    International Nuclear Information System (INIS)

    Prieto, Elena; Peñuelas, Iván; Martí-Climent, Josep M; Lecumberri, Pablo; Gómez, Marisol; Pagola, Miguel; Bilbao, Izaskun; Ecay, Margarita

    2012-01-01

    Tumor volume delineation over positron emission tomography (PET) images is of great interest for proper diagnosis and therapy planning. However, standard segmentation techniques (manual or semi-automated) are operator dependent and time consuming while fully automated procedures are cumbersome or require complex mathematical development. The aim of this study was to segment PET images in a fully automated way by implementing a set of 12 automated thresholding algorithms, classical in the fields of optical character recognition, tissue engineering or non-destructive testing images in high-tech structures. Automated thresholding algorithms select a specific threshold for each image without any a priori spatial information of the segmented object or any special calibration of the tomograph, as opposed to usual thresholding methods for PET. Spherical 18 F-filled objects of different volumes were acquired on clinical PET/CT and on a small animal PET scanner, with three different signal-to-background ratios. Images were segmented with 12 automatic thresholding algorithms and results were compared with the standard segmentation reference, a threshold at 42% of the maximum uptake. Ridler and Ramesh thresholding algorithms based on clustering and histogram-shape information, respectively, provided better results that the classical 42%-based threshold (p < 0.05). We have herein demonstrated that fully automated thresholding algorithms can provide better results than classical PET segmentation tools. (paper)

  18. National variation in preoperative imaging, carotid duplex ultrasound criteria, and threshold for surgery for asymptomatic carotid artery stenosis.

    Science.gov (United States)

    Arous, Edward J; Simons, Jessica P; Flahive, Julie M; Beck, Adam W; Stone, David H; Hoel, Andrew W; Messina, Louis M; Schanzer, Andres

    2015-10-01

    Carotid endarterectomy (CEA) for asymptomatic carotid artery stenosis is among the most common procedures performed in the United States. However, consensus is lacking regarding optimal preoperative imaging, carotid duplex ultrasound criteria, and ultimately, the threshold for surgery. We sought to characterize national variation in preoperative imaging, carotid duplex ultrasound criteria, and threshold for surgery for asymptomatic CEA. The Society for Vascular Surgery Vascular Quality Initiative (VQI) database was used to identify all CEA procedures performed for asymptomatic carotid artery stenosis between 2003 and 2014. VQI currently captures 100% of CEA procedures performed at >300 centers by >2000 physicians nationwide. Three analyses were performed to quantify the variation in (1) preoperative imaging, (2) carotid duplex ultrasound criteria, and (3) threshold for surgery. Of 35,695 CEA procedures in 33,488 patients, the study cohort was limited to 19,610 CEA procedures (55%) performed for asymptomatic disease. The preoperative imaging modality used before CEA varied widely, with 57% of patients receiving a single preoperative imaging study (duplex ultrasound imaging, 46%; computed tomography angiography, 7.5%; magnetic resonance angiography, 2.0%; cerebral angiography, 1.3%) and 43% of patients receiving multiple preoperative imaging studies. Of the 16,452 asymptomatic patients (89%) who underwent preoperative duplex ultrasound imaging, there was significant variability between centers in the degree of stenosis (50%-69%, 70%-79%, 80%-99%) designated for a given peak systolic velocity, end diastolic velocity, and internal carotid artery-to-common carotid artery ratio. Although 68% of CEA procedures in asymptomatic patients were performed for an 80% to 99% stenosis, 26% were performed for a 70% to 79% stenosis, and 4.1% were performed for a 50% to 69% stenosis. At the surgeon level, the range in the percentage of CEA procedures performed for a duplex ultrasound

  19. Perspectives on what we formerly called threshold limit values

    International Nuclear Information System (INIS)

    Goldsmith, J.R.

    1991-01-01

    From the point of view of an epidemiologist with experience in community air quality standards, occupational health standards, radiation standards, and water quality standards, reasons are given for discarding the assumption that occupational health protection should be based on threshold concepts. The weakness of worker health protection based on prescription of maximal exposure levels is noted, regardless of whose judgement is used for such levels. 37 references

  20. 99m-technetium tetrofosmin and 99mTc-methylene diphosphonate in pre-surgical breast cancer

    International Nuclear Information System (INIS)

    Piperkova, E.; Gavrilov, I.; Timcheva, K.; Garanina, Z.; Aleksandrova, E.; Katerinski, K.; Dimitrova, M.

    2004-01-01

    Full text: The aim of this study was to assess the role of the Tc-99m Tetrofosmin (TF) in conjunction with Tc-99m methylenediphosphonate (MDP) in pre-surgical breast cancer (BC) staging. Thirty-six female patients, age range was 32-70 years (average 51.45 years), where the clinical examination, mammography (MG) and fine-needle aspiration cytology were inconclusive were subjected to Tc-99m TF Scintimammography (SMM). All the patients were examined in a specialized breast clinic by experienced surgeons and radiologists. Of the 36 patients, 24 had hyperdense breasts, 8 had undergone lumpectomy or mastectomy due to cancer in one of the breasts and were included in the present study because of suspicion of lesion in the contra lateral breast, 2 had palpable axillary lymph nodes (LN) but no palpable breast lump and 2 patients were of mastitis carcinomatosis. All biopsies were histopathologically verified 740 MBq of Tc-99m TF (Myoview-Amersham) was injected in the arm opposite to the side of the breast lesion. In patients with bilateral breast lesions (BL) radiopharmaceutical was injected in a pedal vein. Planar imaging in prone position was done 10-15 min later. Two lateral views of the left and right breasts including axilla were acquired followed by an anterior view in supine position with arm in an upright position so as to include both breasts and axillary region in the field of imaging view. Imaging was done using a large field of view single-head gamma camera (Diacam-Siemens) coupled with low-energy high-resolution collimator. In patients with locally advanced BC who were to receive pre-operative neo-adjuvant chemotherapy, cardiac GATED SPECT was also acquired using standard protocol. After few days, Tc-99m MDM scintimammography and whole-body bone scintigraphy was also performed. SMM, using the same acquisition protocol as with 99mTc-TF, was done 5-10 min after intravenous injection of 555-740 MBq 99mTc MDP. Standard WBBS was acquired two to three hours later. SMM

  1. Spent 99Mo/99mTc generator as an economical source of 99Mo

    International Nuclear Information System (INIS)

    El-Kolaly, M.T.

    1990-01-01

    An improved method for utilization and purification of 99 Mo from spent 90 Mo/ 99m Tc generators has been described. After washing the generator with saline to remove the generated 99m Tc, followed by 2 mL 5 M NaOH containing a few drops of H 2 O 2 , the 99 Mo was quantitatively eluted from the generator with 5 mL 5 M NaOH. The alkaline eluate containing 99 Mo was contaminated with partially dissolved alumina. In the present method, an anion-exchange resin Dowex 1 x 8 column was used for purification of 99 Mo from the contaminating alumina. The resultant 99 Mo was of high purity and contained 3+ /mL 99 Mo solution, as estimated by atomic absorption. (author)

  2. Clearance of sup(99m)Tc-diisopropyl-IDA in the steady state

    Energy Technology Data Exchange (ETDEWEB)

    Karimeddini, M K; Vogler, M A; Spencer, R P

    1984-10-01

    A 77-year-old man with a stent in lace for biliary drainage was examined. Intravenously administered sup(99m)Tc-diisopropyl-IDA showed little accumulation of activity in the abdomen while the stent was draining internally. Upon switching the stent to external drainage, it was possible to monitor the slow movement of the bile which contained radioactivity. Imaging over the liver and comparing activity changes with a sup(99a)Tc standard showed that the decrease in hepatic radioactivity was identical to that occurring in the sup(99m)Tc standard. The liver was thus in a ''steady state'' for excretion of the sup(99m)Tc hepatobiliary agent, for it was extracting as much radioactivity from the circulation as it was excreting.

  3. Efficient computational model for classification of protein localization images using Extended Threshold Adjacency Statistics and Support Vector Machines.

    Science.gov (United States)

    Tahir, Muhammad; Jan, Bismillah; Hayat, Maqsood; Shah, Shakir Ullah; Amin, Muhammad

    2018-04-01

    Discriminative and informative feature extraction is the core requirement for accurate and efficient classification of protein subcellular localization images so that drug development could be more effective. The objective of this paper is to propose a novel modification in the Threshold Adjacency Statistics technique and enhance its discriminative power. In this work, we utilized Threshold Adjacency Statistics from a novel perspective to enhance its discrimination power and efficiency. In this connection, we utilized seven threshold ranges to produce seven distinct feature spaces, which are then used to train seven SVMs. The final prediction is obtained through the majority voting scheme. The proposed ETAS-SubLoc system is tested on two benchmark datasets using 5-fold cross-validation technique. We observed that our proposed novel utilization of TAS technique has improved the discriminative power of the classifier. The ETAS-SubLoc system has achieved 99.2% accuracy, 99.3% sensitivity and 99.1% specificity for Endogenous dataset outperforming the classical Threshold Adjacency Statistics technique. Similarly, 91.8% accuracy, 96.3% sensitivity and 91.6% specificity values are achieved for Transfected dataset. Simulation results validated the effectiveness of ETAS-SubLoc that provides superior prediction performance compared to the existing technique. The proposed methodology aims at providing support to pharmaceutical industry as well as research community towards better drug designing and innovation in the fields of bioinformatics and computational biology. The implementation code for replicating the experiments presented in this paper is available at: https://drive.google.com/file/d/0B7IyGPObWbSqRTRMcXI2bG5CZWs/view?usp=sharing. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. A new iterative triclass thresholding technique in image segmentation.

    Science.gov (United States)

    Cai, Hongmin; Yang, Zhong; Cao, Xinhua; Xia, Weiming; Xu, Xiaoyin

    2014-03-01

    We present a new method in image segmentation that is based on Otsu's method but iteratively searches for subregions of the image for segmentation, instead of treating the full image as a whole region for processing. The iterative method starts with Otsu's threshold and computes the mean values of the two classes as separated by the threshold. Based on the Otsu's threshold and the two mean values, the method separates the image into three classes instead of two as the standard Otsu's method does. The first two classes are determined as the foreground and background and they will not be processed further. The third class is denoted as a to-be-determined (TBD) region that is processed at next iteration. At the succeeding iteration, Otsu's method is applied on the TBD region to calculate a new threshold and two class means and the TBD region is again separated into three classes, namely, foreground, background, and a new TBD region, which by definition is smaller than the previous TBD regions. Then, the new TBD region is processed in the similar manner. The process stops when the Otsu's thresholds calculated between two iterations is less than a preset threshold. Then, all the intermediate foreground and background regions are, respectively, combined to create the final segmentation result. Tests on synthetic and real images showed that the new iterative method can achieve better performance than the standard Otsu's method in many challenging cases, such as identifying weak objects and revealing fine structures of complex objects while the added computational cost is minimal.

  5. Defining PET standardized uptake value threshold for tumor delineation with metastatic lymph nodes in head and neck cancer

    International Nuclear Information System (INIS)

    Suzuki, Osamu; Nishiyama, Kinji; Morimoto, Masahiro; Nakajima, Aya; Nakamura, Satoaki; Yoshino, Kunitoshi; Hashiguchi, Hajime; Tanaka, Kanji

    2012-01-01

    Hot spots of F-18 fluorodeoxyglucose positron emission tomograms are variable in size according to window settings of standardized uptake values. The purpose of this study was to determine the standardized uptake value threshold that represents the target volume. Sixty-three patients who underwent fluorodeoxyglucose positron emission tomographic computed tomography and were diagnosed as having head and neck cancer with cervical lymphadenopathy were studied. The horizontal and vertical diameters of metastatic lymph nodes (LN-CT) were measured at the center of computed tomographic images. Of the corresponding nodes, the maximal standardized uptake value (SUVmax) and standardized uptake value profiles along the central horizontal and vertical axes were calculated on positron emission tomographic images (LN-PET). On the standardized uptake value profiles, the standardized uptake value levels (SUVeq) where the size of LN-PET was equivalent to the diameters of LN-CT were obtained. The regression formula between SUVeq and SUVmax was obtained. The regression formula of SUVeq was validated in subsequent 30 positron emission tomographic computed tomography studies. The mean horizontal and vertical diameters of LN-CT were 14.9 and 16.4 mm, respectively. SUVmax ranged from 1.88 to 9.07, and SUVeq was between 1.16 and 6.42. The regression formula between SUVeq and SUVmax was as follows: SUVeq =1.21+0.34 x SUVmax (coefficient of correlation: R=0.69). The validation study resulted in a good correlation between the volume of lymph nodes on computed tomography and positron emission tomographic computed tomography (R 2 =0.93). The formula with a relatively high coefficient of correlation is considered to indicate that SUVeq is not constant, but is a complex of an absolute standardized uptake value and is proportional to SUVmax. (author)

  6. GTA Welding Research and Development for Plutonium Containment

    International Nuclear Information System (INIS)

    Sessions, C.E.

    2002-01-01

    This paper discusses the development of two welding systems that are used to contain actinide metals and oxides for long term storage. The systems are termed the bagless transfer system (BTS) and the outer container welder (OCW) system. The BTS is so named because it permits the containment of actinides without a polymeric package (i.e., bag). The development of these two systems was directed by Department of Energy Standard 3013, hereafter referred to as DOE 3013. This document defines the product and container requirements. In addition, it references national codes and standards for leak rates, ANSI N14.5, and design, American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Section VIII (BandPVC)

  7. 40 CFR 86.1729-99-86.1733-99 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false [Reserved] 86.1729-99-86.1733-99 Section 86.1729-99-86.1733-99 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Light-Duty Trucks §§ 86.1729-99—86.1733-99 [Reserved] ...

  8. 40 CFR 86.1736-99-86.1769-99 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false [Reserved] 86.1736-99-86.1769-99 Section 86.1736-99-86.1769-99 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Light-Duty Trucks §§ 86.1736-99—86.1769-99 [Reserved] ...

  9. 40 CFR 86.1718-99-86.1720-99 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 19 2010-07-01 2010-07-01 false [Reserved] 86.1718-99-86.1720-99 Section 86.1718-99-86.1720-99 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... Light-Duty Trucks §§ 86.1718-99—86.1720-99 [Reserved] ...

  10. Determining lower threshold concentrations for synergistic effects

    DEFF Research Database (Denmark)

    Bjergager, Maj-Britt Andersen; Dalhoff, Kristoffer; Kretschmann, Andreas

    2017-01-01

    which proven synergists cease to act as synergists towards the aquatic crustacean Daphnia magna. To do this, we compared several approaches and test-setups to evaluate which approach gives the most conservative estimate for the lower threshold for synergy for three known azole synergists. We focus...... on synergistic interactions between the pyrethroid insecticide, alpha-cypermethrin, and one of the three azole fungicides prochloraz, propiconazole or epoxiconazole measured on Daphnia magna immobilization. Three different experimental setups were applied: A standard 48h acute toxicity test, an adapted 48h test...... of immobile organisms increased more than two-fold above what was predicted by independent action (vertical assessment). All three tests confirmed the hypothesis of the existence of a lower azole threshold concentration below which no synergistic interaction was observed. The lower threshold concentration...

  11. Successful labeling of 99mTc-MDP using 99mTc separated from 99Mo produced by 100Mo(n,2n)99Mo

    International Nuclear Information System (INIS)

    Nagai, Yasuki; Hatsukawa, Yuichi; Kin, Tadahiro; Hashimoto, Kazuyuki; Motoishi, Shoji; Konno, Chikara; Ochiai, Kentaro; Takakura, Kosuke; Sato, Yuichi; Sato, Norihito; Ohta, Akio; Yamabayashi, Hisamichi; Tanase, Masakazu; Fujisaki, Saburo; Kawauchi, Yukimasa; Teranaka, Tomoyuki; Takeuchi, Nobuhiro; Igarashi, Takashi

    2011-01-01

    We have for the first time succeeded in separating 99m Tc from a MoO 3 sample irradiated with accelerator neutrons free from any radioactive impurities and in formulating 99m Tc-methylene diphosphonate ( 99 mTc-MDP). 99 Mo, the mother nuclide of 99m Tc, was produced by the 100 Mo(n,2n) 99 Mo reaction using about 14 MeV neutrons provided by the 3 H(d,n) 4 He reaction at the Fusion Neutronics Source of Japan Atomic Energy Agency. The 99m Tc was separated from 99 Mo by sublimation and its radionuclide purity was confirmed to be higher than 99.99% by γ-spectroscopy. The labeling efficiency of 99m Tc-MDP was shown to be higher than 99% by thin-layer chromatography. These values exceed the United States Pharmacopeia requirements for a fission product, 99 Mo. Consequently, a 99m Tc radiopharmaceutical preparation formed by using the mentioned 99 Mo can be a promising substitute for the fission product 99 Mo, which is currently produced using a highly enriched uranium target in aging research reactors. A longstanding problem to ensure a reliable and constant supply of 99 Mo in Japan can be partially mitigated. (author)

  12. Lower versus higher hemoglobin threshold for transfusion in septic shock.

    Science.gov (United States)

    Holst, Lars B; Haase, Nicolai; Wetterslev, Jørn; Wernerman, Jan; Guttormsen, Anne B; Karlsson, Sari; Johansson, Pär I; Aneman, Anders; Vang, Marianne L; Winding, Robert; Nebrich, Lars; Nibro, Helle L; Rasmussen, Bodil S; Lauridsen, Johnny R M; Nielsen, Jane S; Oldner, Anders; Pettilä, Ville; Cronhjort, Maria B; Andersen, Lasse H; Pedersen, Ulf G; Reiter, Nanna; Wiis, Jørgen; White, Jonathan O; Russell, Lene; Thornberg, Klaus J; Hjortrup, Peter B; Müller, Rasmus G; Møller, Morten H; Steensen, Morten; Tjäder, Inga; Kilsand, Kristina; Odeberg-Wernerman, Suzanne; Sjøbø, Brit; Bundgaard, Helle; Thyø, Maria A; Lodahl, David; Mærkedahl, Rikke; Albeck, Carsten; Illum, Dorte; Kruse, Mary; Winkel, Per; Perner, Anders

    2014-10-09

    Blood transfusions are frequently given to patients with septic shock. However, the benefits and harms of different hemoglobin thresholds for transfusion have not been established. In this multicenter, parallel-group trial, we randomly assigned patients in the intensive care unit (ICU) who had septic shock and a hemoglobin concentration of 9 g per deciliter or less to receive 1 unit of leukoreduced red cells when the hemoglobin level was 7 g per deciliter or less (lower threshold) or when the level was 9 g per deciliter or less (higher threshold) during the ICU stay. The primary outcome measure was death by 90 days after randomization. We analyzed data from 998 of 1005 patients (99.3%) who underwent randomization. The two intervention groups had similar baseline characteristics. In the ICU, the lower-threshold group received a median of 1 unit of blood (interquartile range, 0 to 3) and the higher-threshold group received a median of 4 units (interquartile range, 2 to 7). At 90 days after randomization, 216 of 502 patients (43.0%) assigned to the lower-threshold group, as compared with 223 of 496 (45.0%) assigned to the higher-threshold group, had died (relative risk, 0.94; 95% confidence interval, 0.78 to 1.09; P=0.44). The results were similar in analyses adjusted for risk factors at baseline and in analyses of the per-protocol populations. The numbers of patients who had ischemic events, who had severe adverse reactions, and who required life support were similar in the two intervention groups. Among patients with septic shock, mortality at 90 days and rates of ischemic events and use of life support were similar among those assigned to blood transfusion at a higher hemoglobin threshold and those assigned to blood transfusion at a lower threshold; the latter group received fewer transfusions. (Funded by the Danish Strategic Research Council and others; TRISS ClinicalTrials.gov number, NCT01485315.).

  13. Quantitative analysis of planar technetium-99m-sestamibi myocardial perfusion images using modified background subtraction

    International Nuclear Information System (INIS)

    Koster, K.; Wackers, F.J.; Mattera, J.A.; Fetterman, R.C.

    1990-01-01

    Standard interpolative background subtraction, as used for thallium-201 ( 201 Tl), may create artifacts when applied to planar technetium-99m-Sestamibi ( 99m Tc-Sestamibi) images, apparently because of the oversubtraction of relatively high extra-cardiac activity. A modified background subtraction algorithm was developed and compared to standard background subtraction in 16 patients who had both exercise-delayed 201 Tl and exercise-rest 99m Tc-Sestamibi imaging. Furthermore, a new normal data base was generated. Normal 99m Tc-Sestamibi distribution was slightly different compared to 201 Tl. Using standard background subtraction, mean defect reversibility was significantly underestimated by 99m Tc-Sestamibi compared to 201 Tl (2.8 +/- 4.9 versus -1.8 +/- 8.4, p less than 0.05). Using the modified background subtraction, mean defect reversibility on 201 Tl and 99m Tc-Sestamibi images was comparable (2.8 +/- 4.9 versus 1.7 +/- 5.2, p = NS). We conclude, that for quantification of 99m Tc-Sestamibi images a new normal data base, as well as a modification of the interpolative background subtraction method should be employed to obtain quantitative results comparable to those with 201 Tl

  14. Software thresholds alter the bias of actigraphy for monitoring sleep in team-sport athletes.

    Science.gov (United States)

    Fuller, Kate L; Juliff, Laura; Gore, Christopher J; Peiffer, Jeremiah J; Halson, Shona L

    2017-08-01

    Actical ® actigraphy is commonly used to monitor athlete sleep. The proprietary software, called Actiware ® , processes data with three different sleep-wake thresholds (Low, Medium or High), but there is no standardisation regarding their use. The purpose of this study was to examine validity and bias of the sleep-wake thresholds for processing Actical ® sleep data in team sport athletes. Validation study comparing actigraph against accepted gold standard polysomnography (PSG). Sixty seven nights of sleep were recorded simultaneously with polysomnography and Actical ® devices. Individual night data was compared across five sleep measures for each sleep-wake threshold using Actiware ® software. Accuracy of each sleep-wake threshold compared with PSG was evaluated from mean bias with 95% confidence limits, Pearson moment-product correlation and associated standard error of estimate. The Medium threshold generated the smallest mean bias compared with polysomnography for total sleep time (8.5min), sleep efficiency (1.8%) and wake after sleep onset (-4.1min); whereas the Low threshold had the smallest bias (7.5min) for wake bouts. Bias in sleep onset latency was the same across thresholds (-9.5min). The standard error of the estimate was similar across all thresholds; total sleep time ∼25min, sleep efficiency ∼4.5%, wake after sleep onset ∼21min, and wake bouts ∼8 counts. Sleep parameters measured by the Actical ® device are greatly influenced by the sleep-wake threshold applied. In the present study the Medium threshold produced the smallest bias for most parameters compared with PSG. Given the magnitude of measurement variability, confidence limits should be employed when interpreting changes in sleep parameters. Copyright © 2017 Sports Medicine Australia. All rights reserved.

  15. 99mTc-MAG3 vs 99mTc-DMSA early images: A practice options for the study of renal morphology

    International Nuclear Information System (INIS)

    Fraxedas, R.; Reyes, L.; Rodriguez, J.L.; Perera, A.; Solano, M.E.; Sanchez del Campo, M.

    1997-01-01

    99m Tc- DMSA renal scans are considered a gold standard for the evaluations of cortical defects Nevertheless 99m Tc -MAG3 early images (1-2 min after administration) present clearly defined images of the renal parenchyma. In this work 37 patients with clinical suspicion of upper tract infection were studied with both tracers. Renal ages were evaluated for the presence of cortical defects in a blind fashion by a group of three experts and split function was calculated. Results were highly coincident. It is concluded that early 99mT c -MAG3 can be used to study renal morphology and patient irradiated can be reduced

  16. Effect of milking efficiency on Tc-99 content of Tc-99m derived from Tc-99m generators

    International Nuclear Information System (INIS)

    Bonnyman, J.

    1983-01-01

    Tc-99m obtained by separation from its parent Mo-99 always contains Tc-99 produced by decay of Tc-99m and Mo-99. Factors effecting the Tc-99/Tc-99m ratios are discussed. An HPLC method has been developed to measure the 99 TcO 4- content of sodium pertechnetate from generators with a detection limit of 0.9 ng Tc-99 for a 500 μl/ aliquot of TcO 4- -99m. First eluates of 10 chromatograph-ic generators gave Tc-99/Tc-99m ratios ranging from 3.5-46 ng Tc/mCi Tc-99m measured at the time of milking. The measurements indicate that Tc-99/Tc-99m ratios high enough to cause adverse labelling effects could be found in 'instant pertechnetate' and in the first eluate from Tc-99m generators for the activities normally used in radiopharmaceutical production

  17. Production technologies for molybdenum-99 and technetium-99m

    International Nuclear Information System (INIS)

    1999-02-01

    Technetium-99m (6.02 h) is the most widely used radioisotope in nuclear medicine, accounting for more than 80% of all diagnostic nuclear medicine procedures. It is almost exclusively produced from the decay of its parent 99 Mo. The present sources of 99 Mo are research reactors by using the (n,γ) nuclear reaction with natural Mo ( 98 Mo, ∼24%), resulting in inexpensive but low-specific activity 99 Mo, or by neutron-induced fission of 235 U, which results in expensive but high specific activity 99 Mo. This publication covers several aspects related to the production of 99 Mo and 99m Tc. The contributed papers reflect the current status of the technology and discuss potential alternative methodologies for the production of 99 Mo and 99m Tc for medical use. The first four papers address the technologies using nuclear reactors, including the description of a new method using an aqueous homogenous reactor core for production of fission 99 Mo and the latest development efforts to fabricate 235 U low enriched targets (LEU, 235 U). The next five papers discuss the potential of utilizing particle accelerators and assess the current status of the available nuclear data for the production of both, 99 Mo and 99m Tc with proton and deuteron beams. The last paper discusses a new technology based on gel system for the preparation of 99 Mo/ 99m Tc generators using low specific activity 99 Mo produced in research reactors by the neutron activation of natural and inexpensive molybdenum oxide targets. Each individual paper was indexed and abstracted

  18. A descriptive study of pressure pain threshold at 2 standardized sites in people with acute or subacute neck pain.

    Science.gov (United States)

    Walton, David M; Macdermid, Joy C; Nielson, Warren; Teasell, Robert W; Nailer, Tamara; Maheu, Phillippe

    2011-09-01

    Cross-sectional convenience sample. To describe the distribution of scores for pressure pain threshold (PPT) at 2 standardized testing sites in people with neck pain of less than 90 days' duration: the angle of the upper trapezius and the belly of the tibialis anterior. A secondary objective was to identify important influences on PPT. PPT may be a valuable assessment and prognostic indicator for people with neck pain. However, to facilitate interpretation of scores, knowledge of means and variance for the target population, as well as factors that might influence scores, is needed. Participants were recruited from community-based physiotherapy clinics and underwent PPT testing using a digital algometer and standardized protocol. Descriptive statistics (mean, standard deviations, quartiles, skewness, and kurtosis) were calculated for the 2 sites. Simple bivariate tests of association were conducted to explore potential moderators. A positively skewed distribution was described for the 2 standardized sites. Significant moderators were sex (male higher than female), age (r = 0.22), and self-reported pain intensity (r = -0.24). Neither litigation status nor most symptomatic/least symptomatic side influenced PPT. This manuscript presents information regarding the expected scores for PPT testing in people with acute or subacute neck pain. Clinicians can compare the results of individual patients against these population values, and researchers can incorporate the significant confounders of age, sex, and self-reported pain intensity into future research designs.

  19. Threshold enhancement of diphoton resonances

    Directory of Open Access Journals (Sweden)

    Aoife Bharucha

    2016-10-01

    Full Text Available We revisit a mechanism to enhance the decay width of (pseudo-scalar resonances to photon pairs when the process is mediated by loops of charged fermions produced near threshold. Motivated by the recent LHC data, indicating the presence of an excess in the diphoton spectrum at approximately 750 GeV, we illustrate this threshold enhancement mechanism in the case of a 750 GeV pseudoscalar boson A with a two-photon decay mediated by a charged and uncolored fermion having a mass at the 12MA threshold and a small decay width, <1 MeV. The implications of such a threshold enhancement are discussed in two explicit scenarios: i the Minimal Supersymmetric Standard Model in which the A state is produced via the top quark mediated gluon fusion process and decays into photons predominantly through loops of charginos with masses close to 12MA and ii a two Higgs doublet model in which A is again produced by gluon fusion but decays into photons through loops of vector-like charged heavy leptons. In both these scenarios, while the mass of the charged fermion has to be adjusted to be extremely close to half of the A resonance mass, the small total widths are naturally obtained if only suppressed three-body decay channels occur. Finally, the implications of some of these scenarios for dark matter are discussed.

  20. 'Outbreak Gold Standard' selection to provide optimized threshold for infectious diseases early-alert based on China Infectious Disease Automated-alert and Response System.

    Science.gov (United States)

    Wang, Rui-Ping; Jiang, Yong-Gen; Zhao, Gen-Ming; Guo, Xiao-Qin; Michael, Engelgau

    2017-12-01

    The China Infectious Disease Automated-alert and Response System (CIDARS) was successfully implemented and became operational nationwide in 2008. The CIDARS plays an important role in and has been integrated into the routine outbreak monitoring efforts of the Center for Disease Control (CDC) at all levels in China. In the CIDARS, thresholds are determined using the "Mean+2SD‟ in the early stage which have limitations. This study compared the performance of optimized thresholds defined using the "Mean +2SD‟ method to the performance of 5 novel algorithms to select optimal "Outbreak Gold Standard (OGS)‟ and corresponding thresholds for outbreak detection. Data for infectious disease were organized by calendar week and year. The "Mean+2SD‟, C1, C2, moving average (MA), seasonal model (SM), and cumulative sum (CUSUM) algorithms were applied. Outbreak signals for the predicted value (Px) were calculated using a percentile-based moving window. When the outbreak signals generated by an algorithm were in line with a Px generated outbreak signal for each week, this Px was then defined as the optimized threshold for that algorithm. In this study, six infectious diseases were selected and classified into TYPE A (chickenpox and mumps), TYPE B (influenza and rubella) and TYPE C [hand foot and mouth disease (HFMD) and scarlet fever]. Optimized thresholds for chickenpox (P 55 ), mumps (P 50 ), influenza (P 40 , P 55 , and P 75 ), rubella (P 45 and P 75 ), HFMD (P 65 and P 70 ), and scarlet fever (P 75 and P 80 ) were identified. The C1, C2, CUSUM, SM, and MA algorithms were appropriate for TYPE A. All 6 algorithms were appropriate for TYPE B. C1 and CUSUM algorithms were appropriate for TYPE C. It is critical to incorporate more flexible algorithms as OGS into the CIDRAS and to identify the proper OGS and corresponding recommended optimized threshold by different infectious disease types.

  1. Multiscalar production amplitudes beyond threshold

    CERN Document Server

    Argyres, E N; Kleiss, R H

    1993-01-01

    We present exact tree-order amplitudes for $H^* \\to n~H$, for final states containing one or two particles with non-zero three-momentum, for various interaction potentials. We show that there are potentials leading to tree amplitudes that satisfy unitarity, not only at threshold but also in the above kinematical configurations and probably beyond. As a by-product, we also calculate $2\\to n$ tree amplitudes at threshold and show that for the unbroken $\\phi^4$ theory they vanish for $n>4~$, for the Standard Model Higgs they vanish for $n\\ge 3~$ and for a model potential, respecting tree-order unitarity, for $n$ even and $n>4~$. Finally, we calculate the imaginary part of the one-loop $1\\to n$ amplitude in both symmetric and spontaneously broken $\\phi^4$ theory.

  2. Bedding material affects mechanical thresholds, heat thresholds and texture preference

    Science.gov (United States)

    Moehring, Francie; O’Hara, Crystal L.; Stucky, Cheryl L.

    2015-01-01

    It has long been known that the bedding type animals are housed on can affect breeding behavior and cage environment. Yet little is known about its effects on evoked behavior responses or non-reflexive behaviors. C57BL/6 mice were housed for two weeks on one of five bedding types: Aspen Sani Chips® (standard bedding for our institute), ALPHA-Dri®, Cellu-Dri™, Pure-o’Cel™ or TEK-Fresh. Mice housed on Aspen exhibited the lowest (most sensitive) mechanical thresholds while those on TEK-Fresh exhibited 3-fold higher thresholds. While bedding type had no effect on responses to punctate or dynamic light touch stimuli, TEK-Fresh housed animals exhibited greater responsiveness in a noxious needle assay, than those housed on the other bedding types. Heat sensitivity was also affected by bedding as animals housed on Aspen exhibited the shortest (most sensitive) latencies to withdrawal whereas those housed on TEK-Fresh had the longest (least sensitive) latencies to response. Slight differences between bedding types were also seen in a moderate cold temperature preference assay. A modified tactile conditioned place preference chamber assay revealed that animals preferred TEK-Fresh to Aspen bedding. Bedding type had no effect in a non-reflexive wheel running assay. In both acute (two day) and chronic (5 week) inflammation induced by injection of Complete Freund’s Adjuvant in the hindpaw, mechanical thresholds were reduced in all groups regardless of bedding type, but TEK-Fresh and Pure-o’Cel™ groups exhibited a greater dynamic range between controls and inflamed cohorts than Aspen housed mice. PMID:26456764

  3. Closure Welding of Plutonium Bearing Storage Containers

    International Nuclear Information System (INIS)

    Cannell, G.R.

    2002-01-01

    A key element in the Department of Energy (DOE) strategy for the stabilization, packaging and storage of plutonium-bearing materials involves closure welding of DOE-STD-3013 Outer Containers (3013 container). The 3013 container provides the primary barrier and pressure boundary preventing release of plutonium-bearing materials to the environment. The final closure (closure weld) of the 3013 container must be leaktight, structurally sound and meet DOE STD 3013 specified criteria. This paper focuses on the development, qualification and demonstration of the welding process for the closure welding of Hanford PFP 3013 outer containers

  4. Equivalent threshold sound pressure levels (ETSPL) for Interacoustics DD 45 supra-aural audiometric earphones

    DEFF Research Database (Denmark)

    Poulsen, Torben

    2010-01-01

    This paper describes the determination and results of pure tone Equivalent Threshold Sound Pressure Levels for the Interacoustics DD45 audiometric earphone equipped with standard Model 51 cushions. The size and shape of the DD45 transducer resembles the classical Telephonics TDH 39 earphone. Pure...... tone hearing threshold measurements were performed for both ears of 29 test subjects. All audiometric frequencies from 125 Hz to 8 kHz were used. The data are intended for inclusion in future standardized Reference Equivalent Threshold Sound Pressure Levels. The results show that the DD45 may be a good...

  5. Levels of alarm thresholds of meningitis outbreaks in Hamadan Province, west of Iran.

    Science.gov (United States)

    Faryadres, Mohammad; Karami, Manoochehr; Moghimbeigi, Abbas; Esmailnasab, Nader; Pazhouhi, Khabat

    2015-01-01

    Few studies have focused on syndromic data to determine levels of alarm thresholds to detection of meningitis outbreaks. The purpose of this study was to determine threshold levels of meningitis outbreak in Hamadan Province, west of Iran. Data on both confirmed and suspected cases of meningitis (fever and neurological symptom) form 21 March 2010 to 20 March 2012 were used in Hamadan Province, Iran. Alarm threshold levels of meningitis outbreak were determined using four different methods including absolute values or standard method, relative increase, statistical cutoff points and upper control limit of exponentially weighted moving average (EWMA) algorithm. Among 723 reported cases, 41 were diagnosed to have meningitis. Standard level of alarm thresholds for meningitis outbreak was determined as incidence of 5/100000 persons. Increasing 1.5 to two times in reported cases of suspected meningitis per week was known as the threshold levels according to relative increase method. An occurrence four cases of suspected meningitis per week that equals to 90th percentile was chosen as alarm thresholds by statistical cut off point method. The corresponding value according to EWMA algorithm was 2.57 i.e. three cases. Policy makers and staff of syndromic surveillance systems are highly recommended to apply the above different methods to determine the levels of alarm threshold.

  6. Higgs-Stoponium Mixing Near the Stop-Antistop Threshold

    CERN Document Server

    Bodwin, Geoffrey T; Wagner, Carlos E M

    2016-01-01

    Supersymmetric extensions of the standard model contain additional heavy neutral Higgs bosons that are coupled to heavy scalar top quarks (stops). This system exhibits interesting field theoretic phenomena when the Higgs mass is close to the stop-antistop production threshold. Existing work in the literature has examined the digluon-to-diphoton cross section near threshold and has focused on enhancements in the cross section that might arise either from the perturbative contributions to the Higgs-to-digluon and Higgs-to-diphoton form factors or from mixing of the Higgs boson with stoponium states. Near threshold, enhancements in the relevant amplitudes that go as inverse powers of the stop-antistop relative velocity require resummations of perturbation theory and/or nonperturbative treatments. We present a complete formulation of threshold effects at leading order in the stop-antistop relative velocity in terms of nonrelativistic effective field theory. We give detailed numerical calculations for the case in ...

  7. Tumor affinity of technetium-99m labeled radiopharmaceuticals. II. Sup(99m)Tc-Sn-diphosphonate (sup(99m)Tc-EHDP), sup(99m)Tc-Sn-dimercaptosuccinic acid (sup(99m)Tc-DMSA), sup(99m)Tc-Sn-diethyl stilbestrol diphosphate (sup(99m)Tc-DSDP)

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, K; Kobayashi, S; Hisada, K; Tonami, N [Kanazawa Univ. (Japan). School of Medicine; Ando, A

    1976-10-01

    The authors have examined the tumor affinity of various sup(99m)Tc-labelled radiopharmaceuticals to Ehrlich's tumor for the purpose of delineating human malignant neoplasm positively. The biologic distributions of sup(99m)Tc-Sn-diphosphonate (sup(99m)Tc-EHDP), sup(99m)Tc-Sn-dimercaptosuccinic acid (sup(99m)Tc-DMSA) and sup(99m)Tc-Sn-diethyl stilbestrol diphosphate (sup(99m)Tc-DSDP, sup(99m)Tc-Honvan) are included as the second report on the tumor affinity of Ehrlich-bearing mice. Tumor concentration of sup(99m)Tc-EHDP was lowest and the positive delineation of implanted tumor with sup(99m)Tc-EHDP was poorest in sequential images, though active accumulation in some soft tissues malignant neoplasms, breast cancer, and thyroid cancer, has been reported. Tumor concentration and the tumor-to-blood ratio of sup(99m)Tc-DMSA were not so high, contrary to our expectation that /sup 197/Hg-DMSA might show high tumor concentration and high tumor-to-blood ratio the same as /sup 197/Hg chlormerodrin of the renal scanning radiopharmaceuticals. Tumor concentration of sup(99m)Tc-DSDP was highest. The tumor-to-blood concentration ratio was lower than that of the above mentioned radiopharmaceuticals but the tumor-to-liver ratio and/or tumor-to-lung ratio was over 1.0 at the earlier time. Biologic distribution of sup(99m)Tc-DSDP was similar to that of /sup 32/P labeled DSDP. It is presumed that sup(99m)Tc is labeled at the phosphate ester of DSDP which is dephospholytated immediately by phospholylase in vivo following intravenous injection. Although it is not known precisely it may be assumed that the mechanism of accumulating sup(99m)Tc-DSDP in Ehrlich's tumor is related to the phospholylase activity in neoplasms.

  8. Threshold Evaluation of Emergency Risk Communication for Health Risks Related to Hazardous Ambient Temperature.

    Science.gov (United States)

    Liu, Yang; Hoppe, Brenda O; Convertino, Matteo

    2018-04-10

    Emergency risk communication (ERC) programs that activate when the ambient temperature is expected to cross certain extreme thresholds are widely used to manage relevant public health risks. In practice, however, the effectiveness of these thresholds has rarely been examined. The goal of this study is to test if the activation criteria based on extreme temperature thresholds, both cold and heat, capture elevated health risks for all-cause and cause-specific mortality and morbidity in the Minneapolis-St. Paul Metropolitan Area. A distributed lag nonlinear model (DLNM) combined with a quasi-Poisson generalized linear model is used to derive the exposure-response functions between daily maximum heat index and mortality (1998-2014) and morbidity (emergency department visits; 2007-2014). Specific causes considered include cardiovascular, respiratory, renal diseases, and diabetes. Six extreme temperature thresholds, corresponding to 1st-3rd and 97th-99th percentiles of local exposure history, are examined. All six extreme temperature thresholds capture significantly increased relative risks for all-cause mortality and morbidity. However, the cause-specific analyses reveal heterogeneity. Extreme cold thresholds capture increased mortality and morbidity risks for cardiovascular and respiratory diseases and extreme heat thresholds for renal disease. Percentile-based extreme temperature thresholds are appropriate for initiating ERC targeting the general population. Tailoring ERC by specific causes may protect some but not all individuals with health conditions exacerbated by hazardous ambient temperature exposure. © 2018 Society for Risk Analysis.

  9. Diversification of 99Mo/99mTc separation: non–fission reactor production of 99Mo as a strategy for enhancing 99mTc availability.

    Science.gov (United States)

    Pillai, Maroor R A; Dash, Ashutosh; Knapp, Furn F Russ

    2015-01-01

    This paper discusses the benefits of obtaining (99m)Tc from non-fission reactor-produced low-specific-activity (99)Mo. This scenario is based on establishing a diversified chain of facilities for the distribution of (99m)Tc separated from reactor-produced (99)Mo by (n,γ) activation of natural or enriched Mo. Such facilities have expected lower investments than required for the proposed chain of cyclotrons for the production of (99m)Tc. Facilities can receive and process reactor-irradiated Mo targets then used for extraction of (99m)Tc over a period of 2 wk, with 3 extractions on the same day. Estimates suggest that a center receiving 1.85 TBq (50 Ci) of (99)Mo once every 4 d can provide 1.48-3.33 TBq (40-90 Ci) of (99m)Tc daily. This model can use research reactors operating in the United States to supply current (99)Mo needs by applying natural (nat)Mo targets. (99)Mo production capacity can be enhanced by using (98)Mo-enriched targets. The proposed model reduces the loss of (99)Mo by decay and avoids proliferation as well as waste management issues associated with fission-produced (99)Mo.

  10. Data quality objectives for moisture measurement in stabilized special nuclear material

    International Nuclear Information System (INIS)

    Weier, D.R.; Pulsipher, B.A.; Silvers, K.L.

    2000-01-01

    Data Quality Objectives methodology is applied to Loss-on-Ignition (LOI) moisture content testing for stabilized nuclear materials. This work was performed by Pacific Northwest National Laboratory in support of the Plutonium Finishing Plant (PFP)/Fluor Hanford, Inc. Historical results on LOI test results for two material types, oxide and sludge, are used to estimate within container variability. This variability estimate is then used in formulating the two recommended acceptance criteria for containers of material. The criteria which follow are proposed to replace the current criterion, which requires recycle if either of two container LOI measurements exceed 0.5 wt%, the DOE Standard 3013-99 threshold value. (1) The 95% upper confidence limit (UCL) for the true mean underlying moisture content in the container material should be less than 0.5 wt%. (2) The difference between the two LOI measurements per container should not exceed their expected 95th percentile relative to the estimated variability. Containers not meeting the first criterion, or those that generate in any negative LOI result, require material recycle. Containers not meeting the second criteria require review of the measurement results, potentially leading to resampling and retesting. Data from Los Alamos National Laboratory studies on moisture testing are obtained and analyzed. The performance of Supercritical Fluid Extraction (SFE), which will soon be implemented at the PFP, is described for several material types. This information will be used to establish initial acceptance criteria when SFE comes on line

  11. A comparison of rat SPECT images obtained using 99mTc derived from 99Mo produced by an electron accelerator with that from a reactor

    International Nuclear Information System (INIS)

    Galea, R; Ross, C K; Moore, K; Wells, R G; Lockwood, J; Harvey, J T; Isensee, G H

    2013-01-01

    Recent shortages of molybdenum-99 ( 99 Mo) have led to an examination of alternate production methods that could contribute to a more robust supply. An electron accelerator and the photoneutron reaction were used to produce 99 Mo from which technetium-99m ( 99m Tc) is extracted. SPECT images of rat anatomy obtained using the accelerator-produced 99m Tc with those obtained using 99m Tc from a commercial generator were compared. Disks of 100 Mo were irradiated with x-rays produced by a 35 MeV electron beam to generate about 1110 MBq (30 mCi) of 99 Mo per disk. After target dissolution, a NorthStar ARSII unit was used to separate the 99m Tc, which was subsequently used to tag pharmaceuticals suitable for cardiac and bone imaging. SPECT images were acquired for three rats and compared to images for the same three rats obtained using 99m Tc from a standard reactor 99 Mo generator. The efficiency of 99 Mo– 99m Tc separation was typically greater than 90%. This study demonstrated the delivery of 99m Tc from the end of beam to the end user of approximately 30 h. Images obtained using the heart and bone scanning agents using reactor and linac-produced 99m Tc were comparable. High-power electron accelerators are an attractive option for producing 99 Mo on a national scale. (paper)

  12. Evaluation of '9{sup 9}Mo presence in eluates of {sup 99}mTc used in nuclear medicine; Avaliacao da presenca de {sup 99}Mo em eluatos de {sup 99m}Tc utilizados em medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Bianca da Silva

    2010-07-01

    Tc-99m is used for diagnostic imaging in nuclear medicine through SPECT technique. It is obtained by the elution of {sup 99}Mo/{sup 99m}Tc generators. During the elution process {sup 99}Mo can be extracted becoming a radionuclidic impurity. One of the quality parameters of the eluate is the radionuclidic purity, MBT (molybdenum break through), defined as the ratio between {sup 99}Mo and {sup 99m}Tc activities in the eluate. The North-American and European pharmacopoeias restrict the {sup 99}Mo content, respectively, in 0.015 e 0.1% and, according to the International Atomic Energy Agency (IAEA), the activity ratio at the moment of administration of the radiopharmaceutical to the patient, should not exceed 0.015%. In Brazil, the control of such parameter is not obliged in official regulations. Thus, the objective of this work is to evaluate the occurrence of {sup 99}Mo in {sup 99m}Tc eluates. It was initially optimized a methodology to determine the activity of {sup 99}Mo in eluate samples. Efficiency curves were obtained for a NaI (Tl) 8'' x 4'' scintillation detector installed at the In Vivo Monitoring Laboratory (LABMIV-IRD). The methodology has been validated through the measurement of a {sup 99}Mo standard liquid source calibrated at the National Metrology Laboratory for Ionizing Radiation (LNMRI-IRD). The samples analyzed in this work were gently supplied by 5 Nuclear Medicine Clinics located in the city of Rio de Janeiro. The activities of {sup 99}mTc and {sup 99}Mo in those samples have been measured respectively at the clinics and at the LABMIV. By applying a standardized methodology, the ration between the activities were calculated. The results show that 147 out of 174 samples presented {sup 99}Mo activities above the minimum detectable activity of the technique. On the other hand, only 2 out of 147 samples surpassed the MBT limit suggested by the IAEA and have been detected in samples eluted from generators of 750 mCi. In one of the

  13. Status of Tc-99m and 99Mo/99mTc generator production in Bangladesh

    International Nuclear Information System (INIS)

    Abedin, Md. Zainul; Haque, Md. Azizul; Ali, Md. Ramjan; Hossain, Md. Anwar; Razzaque, Md. Abdur; Yasmin, Lyzu; Waheed, M. Fatima; Akhter, Rabeya; Mondal, Rafiuddin

    2007-01-01

    Radioisotope Production Division (RIPD) produced instant technetium-99m by solvent extraction method for several years. On R and D basis, the division produced portable sterile Tc-99m sublimation generator by irradiating titanium molybdate in the reactor. The division produced (4/batch) from imported fission Mo-99 till June 2005. Since August 2005, as per demand of the government hospitals, the division have been producing 12-14 pieces of 15 GBq chromatographic 99m Tc-generators weekly by using the new generator production plant installed last year having online Mo-99 loading system with the of producing 50 generator per batch. Development of PZC and (n,γ) 99 Mo based generator holds potential in Bangladesh. (author)

  14. Pharmaceutical grade sodium (99mTc) pertechnetate from 99Mo/99mTc-TCM-Autosolex generator

    International Nuclear Information System (INIS)

    Chattopadhyay, Sankha; Barua, Luna; Das, Sujata Saha

    2014-01-01

    Technetium-99m (T 1/2 = 6.02h; 140.51 keV (89%)) is the most useful radioisotope in diagnostic nuclear medicine. More than 80% of all diagnostic procedures done worldwide in nuclear medicine centre are performed with 99m Tc. Worldwide crisis of fission 99 Mo based generator in recent past had put the nuclear medicine fraternity in very harsh situation. In order to have an indigenous solution of this problem, we tried to develop a computer controlled semi automated 99 Mo/ 99m Tc generator using MEK solvent extraction technique, which utilizes abundantly available 99 Mo produced by (n,γ) reaction in BARC reactors. The aim of this work is to provide a more reliable, computer controlled module (TCM- AUTOSOLEX) for the recovery of pharmaceutical grade 99m Tc from low specific activity 99 Mo based on solvent extraction methodology

  15. Comparison of Size Modulation Standard Automated Perimetry and Conventional Standard Automated Perimetry with a 10-2 Test Program in Glaucoma Patients.

    Science.gov (United States)

    Hirasawa, Kazunori; Takahashi, Natsumi; Satou, Tsukasa; Kasahara, Masayuki; Matsumura, Kazuhiro; Shoji, Nobuyuki

    2017-08-01

    This prospective observational study compared the performance of size modulation standard automated perimetry with the Octopus 600 10-2 test program, with stimulus size modulation during testing, based on stimulus intensity and conventional standard automated perimetry, with that of the Humphrey 10-2 test program in glaucoma patients. Eighty-seven eyes of 87 glaucoma patients underwent size modulation standard automated perimetry with Dynamic strategy and conventional standard automated perimetry using the SITA standard strategy. The main outcome measures were global indices, point-wise threshold, visual defect size and depth, reliability indices, and test duration; these were compared between size modulation standard automated perimetry and conventional standard automated perimetry. Global indices and point-wise threshold values between size modulation standard automated perimetry and conventional standard automated perimetry were moderately to strongly correlated (p 33.40, p modulation standard automated perimetry than with conventional standard automated perimetry, but the visual-field defect size was smaller (p modulation-standard automated perimetry than on conventional standard automated perimetry. The reliability indices, particularly the false-negative response, of size modulation standard automated perimetry were worse than those of conventional standard automated perimetry (p modulation standard automated perimetry than with conventional standard automated perimetry (p = 0.02). Global indices and the point-wise threshold value of the two testing modalities correlated well. However, the potential of a large stimulus presented at an area with a decreased sensitivity with size modulation standard automated perimetry could underestimate the actual threshold in the 10-2 test protocol, as compared with conventional standard automated perimetry.

  16. Higher vs. lower haemoglobin threshold for transfusion in septic shock

    DEFF Research Database (Denmark)

    Rygård, S L; Holst, L B; Wetterslev, J

    2017-01-01

    . a lower haemoglobin threshold. METHODS: In post-hoc analyses of the full trial population of 998 patients from the Transfusion Requirements in Septic Shock (TRISS) trial, we investigated the intervention effect on 90-day mortality in patients with severe comorbidity (chronic lung disease, haematological......BACKGROUND: Using a restrictive transfusion strategy appears to be safe in sepsis, but there may be subgroups of patients who benefit from transfusion at a higher haemoglobin level. We explored if subgroups of patients with septic shock and anaemia had better outcome when transfused at a higher vs.......51), in those who had undergone surgery (P = 0.99) or in patients with septic shock by the new definition (P = 0.20). CONCLUSION: In exploratory analyses of a randomized trial in patients with septic shock and anaemia, we observed no survival benefit in any subgroups of transfusion at a haemoglobin threshold...

  17. Deriving fuel-based emission factor thresholds to interpret heavy-duty vehicle roadside plume measurements.

    Science.gov (United States)

    Quiros, David C; Smith, Jeremy D; Ham, Walter A; Robertson, William H; Huai, Tao; Ayala, Alberto; Hu, Shaohua

    2018-04-13

    Remote sensing devices have been used for decades to measure gaseous emissions from individual vehicles at the roadside. Systems have also been developed that entrain diluted exhaust and can also measure particulate matter (PM) emissions. In 2015, the California Air Resources Board (CARB) reported that 8% of in-field diesel particulate filters (DPF) on heavy-duty (HD) vehicles were malfunctioning and emitted about 70% of total diesel PM emissions from the DPF-equipped fleet. A new high-emitter problem in the heavy-duty vehicle fleet had emerged. Roadside exhaust plume measurements reflect a snapshot of real-world operation, typically lasting several seconds. In order to relate roadside plume measurements to laboratory emission tests, we analyzed carbon dioxide (CO 2 ), oxides of nitrogen (NO X ), and PM emissions collected from four HD vehicles during several driving cycles on a chassis dynamometer. We examined the fuel-based emission factors corresponding to possible exceedances of emission standards as a function of vehicle power. Our analysis suggests that a typical HD vehicle will exceed the model year (MY) 2010 emission standards (of 0.2 g NO X /bhp-hr and 0.01 g PM/bhp-hr) by three times when fuel-based emission factors are 9.3 g NO X /kg fuel and 0.11 g PM/kg using the roadside plume measurement approach. Reported limits correspond to 99% confidence levels, which were calculated using the detection uncertainty of emissions analyzers, accuracy of vehicle power calculations, and actual emissions variability of fixed operational parameters. The PM threshold was determined for acceleration events between 0.47 and 1.4 mph/sec only, and the NO X threshold was derived from measurements where aftertreatment temperature was above 200°C. Anticipating a growing interest in real-world driving emissions, widespread implementation of roadside exhaust plume measurements as a compliment to in-use vehicle programs may benefit from expanding this analysis to a larger

  18. Emergent dynamics of spiking neurons with fluctuating threshold

    Science.gov (United States)

    Bhattacharjee, Anindita; Das, M. K.

    2017-05-01

    Role of fluctuating threshold on neuronal dynamics is investigated. The threshold function is assumed to follow a normal probability distribution. Standard deviation of inter-spike interval of the response is computed as an indicator of irregularity in spike emission. It has been observed that, the irregularity in spiking is more if the threshold variation is more. A significant change in modal characteristics of Inter Spike Intervals (ISI) is seen to occur as a function of fluctuation parameter. Investigation is further carried out for coupled system of neurons. Cooperative dynamics of coupled neurons are discussed in view of synchronization. Total and partial synchronization regimes are depicted with the help of contour plots of synchrony measure under various conditions. Results of this investigation may provide a basis for exploring the complexities of neural communication and brain functioning.

  19. Optimization, validation and standardization of a method of measuring the radiochemical purity of 99mTc-HMDP in Necker hospital

    International Nuclear Information System (INIS)

    Dumont, A.; Izembart, M.; Barritault, L.

    1997-01-01

    By the end of 1996, the tests of the radiochemical purity (RCP) of preparation of HMDP- 99m Tc at Necker hospital were effected by means of 'Tech-Kit' technique which allowed making evident only one radiochemical impurity, the free TcO 4 - . So, the aim of this work has been the search for another technique able to detect also the reduced hydrolyzed 99m Tc, and then, to optimize, validate and standardize this new technique. Several methods have been tested and compared on different points (the chemical species identified, practical difficulties, duration, reproducibility) in order to chose 'the best' one, consisting in associating two TLC (migration time, 3 minutes): - TLC no.1, ITLC-SG/Methyl-ethyl-ketone; - TLC no.2, ITLC-SG/1M Sodium acetate. This method has been subsequently: - optimized, concerning the quantity of deposed sampling, way of deposit drying, migration range, reading protocol by radio-chromatograph; - validated, by verifying the migration of radiochemical impurities by means of controls and by evaluating its sensitivity; - standardized, by defining the interest zones for interpreting the radio-chromatograms, by evaluating the reproducibility and by calculating the 'normal values' of RCP percentages. This method has been adopted as routine and with current recoil (40 preparations) and our conditions of realizations, the extreme values of the percentages obtained for the impurity zones of interests, have been the following: - TcO 4 - zone, [0.39%-1.07%]; - hydrolyzed reduced Tc zone, [0.96%-5.09%]. By taking into account their distribution we calculated a minimum RCP value of 94% to accept the preparation (the RCP being defined as equal to 100% - % TcO 4 - % hydrolyzed reduced Tc)

  20. Quantitative planar imaging with technetium-99m methoxyisobutyl isonitrile: Comparison of uptake patterns with thallium-201

    International Nuclear Information System (INIS)

    Sinusas, A.J.; Beller, G.A.; Smith, W.H.; Vinson, E.L.; Brookeman, V.; Watson, D.D.

    1989-01-01

    To compare the myocardial uptake pattern of 99mTc-labeled methoxyisobutyl isonitrile [( 99mTc] MIBI) and 201TI, planar scintigraphy were performed in both patients with documented coronary artery disease and subjects with a low likelihood of disease. Quantitative analysis was employed using a standard interpolative background subtraction algorithm and a new algorithm modified to better accommodate for the differences in extracardiac activity seen with [99mTc]MIBI rest images. Among patients with coronary artery disease, the standard algorithm yielded no significant difference in relative defect magnitude between [99mTc]MIBI and 201TI on stress scintigrams (p = 0.48), although the magnitude of [99mTc]MIBI defects was greater on resting images (p = 0.02). When the modified algorithm was employed, defect magnitude was similar for both stress (p = 0.91) and rest (p = 0.20) images. Normal segmental uptake ratios derived from a comparison of contralateral segments (e.g., septal:posterolateral) in the low likelihood patients were similar for both [99mTc]MIBI and 201TI. Thus, modification of the standard interpolative background subtraction algorithm is necessary for quantitative planar [99mTc]MIBI perfusion imaging. When appropriate background subtraction is employed, myocardial uptake and quantitative defect magnitude of [99mTc]MIBI and 201TI planar images are similar

  1. Influence of regression model and incremental test protocol on the relationship between lactate threshold using the maximal-deviation method and performance in female runners.

    Science.gov (United States)

    Machado, Fabiana Andrade; Nakamura, Fábio Yuzo; Moraes, Solange Marta Franzói De

    2012-01-01

    This study examined the influence of the regression model and initial intensity of an incremental test on the relationship between the lactate threshold estimated by the maximal-deviation method and the endurance performance. Sixteen non-competitive, recreational female runners performed a discontinuous incremental treadmill test. The initial speed was set at 7 km · h⁻¹, and increased every 3 min by 1 km · h⁻¹ with a 30-s rest between the stages used for earlobe capillary blood sample collection. Lactate-speed data were fitted by an exponential-plus-constant and a third-order polynomial equation. The lactate threshold was determined for both regression equations, using all the coordinates, excluding the first and excluding the first and second initial points. Mean speed of a 10-km road race was the performance index (3.04 ± 0.22 m · s⁻¹). The exponentially-derived lactate threshold had a higher correlation (0.98 ≤ r ≤ 0.99) and smaller standard error of estimate (SEE) (0.04 ≤ SEE ≤ 0.05 m · s⁻¹) with performance than the polynomially-derived equivalent (0.83 ≤ r ≤ 0.89; 0.10 ≤ SEE ≤ 0.13 m · s⁻¹). The exponential lactate threshold was greater than the polynomial equivalent (P performance index that is independent of the initial intensity of the incremental test and better than the polynomial equivalent.

  2. Efficient RSA Key Generation and Threshold Paillier in the Two-Party Setting

    DEFF Research Database (Denmark)

    Hazay, Carmit; Mikkelsen, Gert Læssøe; Rabin, Tal

    2011-01-01

    with security against malicious behavior. Our second contribution is complete Paillier [Pai99] threshold encryption scheme in the two-party setting with security against malicious behavior. Furthermore, we describe how to extend our protocols to the multiparty setting with dishonest majority. Our RSA key...... generation is comprised of the following: (i) a distributed protocol for generation of an RSA composite, and (ii) a biprimality test for verifying the validity of the generated composite. Our Paillier threshold encryption scheme uses the RSA composite as public key and is comprised of: (i) a distributed......The problem of generating an RSA composite in a distributed manner without leaking its factorization is particularly challenging and useful in many cryptographic protocols. Our first contribution is the first non-generic fully simulatable protocol for distributively generating an RSA composite...

  3. Compressed air injection technique to standardize block injection pressures.

    Science.gov (United States)

    Tsui, Ban C H; Li, Lisa X Y; Pillay, Jennifer J

    2006-11-01

    Presently, no standardized technique exists to monitor injection pressures during peripheral nerve blocks. Our objective was to determine if a compressed air injection technique, using an in vitro model based on Boyle's law and typical regional anesthesia equipment, could consistently maintain injection pressures below a 1293 mmHg level associated with clinically significant nerve injury. Injection pressures for 20 and 30 mL syringes with various needle sizes (18G, 20G, 21G, 22G, and 24G) were measured in a closed system. A set volume of air was aspirated into a saline-filled syringe and then compressed and maintained at various percentages while pressure was measured. The needle was inserted into the injection port of a pressure sensor, which had attached extension tubing with an injection plug clamped "off". Using linear regression with all data points, the pressure value and 99% confidence interval (CI) at 50% air compression was estimated. The linearity of Boyle's law was demonstrated with a high correlation, r = 0.99, and a slope of 0.984 (99% CI: 0.967-1.001). The net pressure generated at 50% compression was estimated as 744.8 mmHg, with the 99% CI between 729.6 and 760.0 mmHg. The various syringe/needle combinations had similar results. By creating and maintaining syringe air compression at 50% or less, injection pressures will be substantially below the 1293 mmHg threshold considered to be an associated risk factor for clinically significant nerve injury. This technique may allow simple, real-time and objective monitoring during local anesthetic injections while inherently reducing injection speed.

  4. 64 x 64 thresholding photodetector array for optical pattern recognition

    Science.gov (United States)

    Langenbacher, Harry; Chao, Tien-Hsin; Shaw, Timothy; Yu, Jeffrey W.

    1993-10-01

    A high performance 32 X 32 peak detector array is introduced. This detector consists of a 32 X 32 array of thresholding photo-transistor cells, manufactured with a standard MOSIS digital 2-micron CMOS process. A built-in thresholding function that is able to perform 1024 thresholding operations in parallel strongly distinguishes this chip from available CCD detectors. This high speed detector offers responses from one to 10 milliseconds that is much higher than the commercially available CCD detectors operating at a TV frame rate. The parallel multiple peaks thresholding detection capability makes it particularly suitable for optical correlator and optoelectronically implemented neural networks. The principle of operation, circuit design and the performance characteristics are described. Experimental demonstration of correlation peak detection is also provided. Recently, we have also designed and built an advanced version of a 64 X 64 thresholding photodetector array chip. Experimental investigation of using this chip for pattern recognition is ongoing.

  5. Study of methodologies for quality control of 99Mo used in 99Mo/99mTc generators

    International Nuclear Information System (INIS)

    Said, Daphne de Souza

    2016-01-01

    99m Tc is the most used radionuclide in nuclear medicine. In Brazil, the 99 Mo/ 99m Tc generators are exclusively produced by Radiopharmacy Center at IPEN-CNEN/ SP, by importing 99 Mo from different suppliers. 99 Mo (t 1/2 = 66 h) is a fission product of 235 U and it can have radionuclidic impurities that are prejudicial for human health. For safe use of generators, it is necessary to perform the evaluation of 99 Mo by quality control tests in order to assess if 99 Mo complies with the specifications. The European Pharmacopoeia (EP) presents a monograph for evaluation of the quality of the [ 99 Mo] solution as sodium molybdate,that is used as raw material for 99 Mo/ 99m Tc generators production, including specification parameters (identification, radiochemical purity and radionuclidic purity), analysis methods and limits. However, it has been observed difficulties on the execution and implementation of these methods by the generators producers, with a few literature about this subject, probably due to complexity of the proposed methods. In this work, many quality control parameters of 99 Mo described in the EP monograph were evaluated. Separation methods for 99M o from its radionuclidic impurities by solid phase extraction (SPE) and TLC were studied. After SPE separation, the quantification of metals by ICP-OES to evaluate the percentage of retention of Mo and the percentage of recovery of Ru, Te and Sr using different types of cartridges were proposed, replacing radiotracers use. It was observed that the specific type of SPE cartridge recommended by the EP for separation of 99 Mo presented low recoveries for Ru, compared to other available anion exchange SPE cartridges. 99 Mo samples from different worldwide suppliers were analyzed. It was observed that quantification of 103 Ru in 99 Mo samples with decay time higher than 4 weeks is possible. An alternative method for separation of 131 I from 99 Mo showed promising results by TLC. The quantification of beta and

  6. Threshold quantum cryptography

    International Nuclear Information System (INIS)

    Tokunaga, Yuuki; Okamoto, Tatsuaki; Imoto, Nobuyuki

    2005-01-01

    We present the concept of threshold collaborative unitary transformation or threshold quantum cryptography, which is a kind of quantum version of threshold cryptography. Threshold quantum cryptography states that classical shared secrets are distributed to several parties and a subset of them, whose number is greater than a threshold, collaborates to compute a quantum cryptographic function, while keeping each share secretly inside each party. The shared secrets are reusable if no cheating is detected. As a concrete example of this concept, we show a distributed protocol (with threshold) of conjugate coding

  7. Initial direct comparison of 99mTc-TOC and 99mTc-TATE in identifying sites of disease in patients with proven GEP NETs.

    Science.gov (United States)

    Cwikla, Jaroslaw B; Mikolajczak, Renata; Pawlak, Dariusz; Buscombe, John R; Nasierowska-Guttmejer, Anna; Bator, Andrzej; Maecke, Helmut R; Walecki, Jerzy

    2008-07-01

    The imaging of neuroendocrine tumors has become one of the most significant areas in nuclear oncology. In an attempt to provide high-quality imaging and possible sensitivity at a reduced cost, time, and radiation dose, several (99m)Tc agents have been proposed. The aim of this initial study was to compare the tumor uptake and biodistribution of 2 new 6-hydrazinopyridine-3-carboxylic acid (HYNIC)-derivatized Tyr(3)-octreotide analogs, (99m)Tc-[HYNIC,Tyr(3)]octreotide ((99m)Tc-TOC) and (99m)Tc-[HYNIC,Tyr(3),Thr(8)]octreotide ((99m)Tc-TATE), in patients with somatostatin receptor-expressing tumors. Each of 12 patients with proven gastrointestinal pancreatic neuroendocrine tumors received a mean activity of 520 MBq of (99m)Tc-TOC and (99m)Tc-TATE. Scintigraphy with both tracers was performed 3-4 h after their injection using standard whole-body and SPECT imaging. The images were reviewed subjectively by 2 readers, who reported tumor uptake lesion by lesion. Both radiotracers demonstrated concordance between the results in 7 patients (58%). In total, 110 sites of disease were identified with (99m)Tc-TOC, compared with 115 with (99m)Tc-TATE. There was 1 case in which (99m)Tc-TOC identified sites of disease not seen on (99m)Tc-TATE imaging but 4 cases in which some sites of disease were seen with (99m)Tc-TATE and not (99m)Tc-TOC. In this initial study, both tracers seem to show similar sites of tumor, with (99m)Tc-TATE having a slight edge in the total number of lesions seen, especially in lymph node metastases.

  8. Infrared skin damage thresholds from 1319-nm continuous-wave laser exposures

    Science.gov (United States)

    Oliver, Jeffrey W.; Vincelette, Rebecca; Noojin, Gary D.; Clark, Clifton D.; Harbert, Corey A.; Schuster, Kurt J.; Shingledecker, Aurora D.; Kumru, Semih S.; Maughan, Justin; Kitzis, Naomi; Buffington, Gavin D.; Stolarski, David J.; Thomas, Robert J.

    2013-12-01

    A series of experiments were conducted in vivo using Yucatan miniature pigs (Sus scrofa domestica) to determine thermal damage thresholds to the skin from 1319-nm continuous-wave Nd:YAG laser irradiation. Experiments employed exposure durations of 0.25, 1.0, 2.5, and 10 s and beam diameters of ˜0.6 and 1 cm. Thermal imagery data provided a time-dependent surface temperature response from the laser. A damage endpoint of fifty percent probability of a minimally visible effect was used to determine threshold for damage at 1 and 24 h postexposure. Predicted thermal response and damage thresholds are compared with a numerical model of optical-thermal interaction. Resultant trends with respect to exposure duration and beam diameter are compared with current standardized exposure limits for laser safety. Mathematical modeling agreed well with experimental data, predicting that though laser safety standards are sufficient for exposures <10 s, they may become less safe for very long exposures.

  9. Current status of production and supply of molybdenum-99 and 99Mo/99mTc generators in Indonesia

    International Nuclear Information System (INIS)

    Mutalib, A.

    2003-01-01

    Production of high-specific activity molybdenum-99 and 99 Mo/ 99m Tc Generators in Indonesia commenced when a new production facility supported by the presence of a 30 MW multipurpose reactor (RSG-GAS) was established in Serpong in 1990. This report describes the current production and supply of molybdenum-99m devoted mainly to fulfill the domestic demands in supplying 99 Mo/ 99m Tc Generators. Recent development on the use of LEU (Low Enriched Uranium) targets for replacing current HEU (High Enriched Uranium) targets in the production of 99 Mo will be reviewed briefly. (author)

  10. Measurement of Mo-99 column activity in the evaluation of Mo-99/Tc-99m generator

    International Nuclear Information System (INIS)

    Kuster, Z.

    1994-01-01

    In order to calculate the real elution efficiency of Mo-99/Tc-99m generator the Mo-99 content on the column has to be previously determined. As found in this work, the external measurement of Mo-99-column activity by means of Geiger-Mueller counter is a simple, fast and reliable method. Generally, Mo-99-column is placed slightly out of the center of the generator; therefore the externally measured flux of photons (φ) is an angular-dependent function. If the thickness of the lead container is radially uniform, the flux measured at some distance from the generator (which is rotated in 2π/3 steps) is given by the equation φ = A (1 + Bcos (α-2π(i - 2)/3)) -1 , i=1,2 or 3 (Eq.1) where A is a numerical constant depending on the Mo-99-column activity, B is a numerical constant depending on the Mo-99- column position within the lead container, the angle α depends on the initial orientation of the generator. A total of 20 generator were studied. The measured Mo-99-column activities (Capintec dose calibrator) were in the range 13.1- 35.11 GBq. Contrary to the findings of Vinberg and Kristensen (Eur J Nucl Med 1/1976(219), values of A (Eq. 1) are in good correlation (r 2 =0.9794) with the measured Mo-99-column activities. (author)

  11. Standard Test Method for Measurement of Hydrogen Embrittlement Threshold in Steel by the Incremental Step Loading Technique

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method establishes a procedure to measure the susceptibility of steel to a time-delayed failure such as that caused by hydrogen. It does so by measuring the threshold for the onset of subcritical crack growth using standard fracture mechanics specimens, irregular-shaped specimens such as notched round bars, or actual product such as fasteners (2) (threaded or unthreaded) springs or components as identified in SAE J78, J81, and J1237. 1.2 This test method is used to evaluate quantitatively: 1.2.1 The relative susceptibility of steels of different composition or a steel with different heat treatments; 1.2.2 The effect of residual hydrogen in the steel as a result of processing, such as melting, thermal mechanical working, surface treatments, coatings, and electroplating; 1.2.3 The effect of hydrogen introduced into the steel caused by external environmental sources of hydrogen, such as fluids and cleaners maintenance chemicals, petrochemical products, and galvanic coupling in an aqueous enviro...

  12. Technetium-99m-labelled monoclonal antibody fragment (99mTc-DD-3B6/22Fab') for ovarian cancer

    International Nuclear Information System (INIS)

    Fernandes, V.; Donaghy, T.; Prabakaran, K.; Smith, S.; Clingan, P.; Bartolo, N.; Bundesen, P.; Hillyard, C.

    1998-01-01

    Full text: This study is the first to assess 99m Tc-DD-3B6/22Fab'' as an agent for detecting OC recurrence. Five informed consenting volunteers with stages 3 or 4 OC (mean age 54.2 y) and with negative skin prick test to Fab'' were recruited. All had suspicion of OC recurrence, with elevated serum tumour marker CA125, and in some, OC confirmation on CT scans. Aggressive treatment was continued so that tumour regression was possible prior to 99m Tc-DD-3B6/22Fab''scan. CA125, FBC, biochemical and clot markers were measured pre-and post-study. All received IV 600-800 MBq of 99 mTc-DD-3B6/22Fab''. Temperature, pulse and BP were monitored for one hour. Data were acquired with a single head LFOV gamma camera and HIRES collimator at 1,4,6 and 24 hours. Studies were read for OC lesions which were scored as probably normal (PN) or abnormal (PAb), definitely abnormal (DAb). The gold standard was CA125 immediately post-scan and, when possible, confirmation with CT. Of 5 patients, 1 was disease negative with 99 mTc-DD-3B6/22Fab'', CA125 suggesting remission, and 4 were positive on all modalities (Sensitivity, specificity, 100% respectively). 99 mTc-DD-3B6/22Fab'' identified 15 lesions (100% DAb). CT detected 7 lesions (71% Dab) pre- 99 mTc-DD-3B6/22Fab''. Repeat CT detected 8 (100% DAb). Correlation with CA125 levels was best with 99 mTc-DD3B6/22Fab''. No side effects or adverse change in serum markers were noted. 99 mTc-DD-3B6/22Fab'' is sensitive and specific for detecting OC recurrence

  13. Comparative study of gated myocardial perfusion imaging using 99Tcm-tetrofosmin and 99Tcm-sestamibi

    International Nuclear Information System (INIS)

    Wang Ruihua; Ruan Qiao; Sun Ke; Han Xingmin; Sun Bingqi; Xie Xinli; Cheng Bing; Chen Yanlin; Liu Baoping

    2013-01-01

    Objective: To compare the results of 99 Tc m -tetrofosmin (TF) and 99 Tc m -MIBI G-MPI in evaluating left ventricular myocardial perfusion and other functional parameters. Methods: TF and MIBI were both labeled by 99 Tc m and the radiochemical purities were tested. During December 2011 to May 2012, 112 patients who had examinations of CAG and echocardiograph in one week after G-MPI were divided into 99 Tc m -TF group (47 patients) and 99 Tc m -MIBI group (65 patients) by simple random sampling. Patients who suffered from severe arrhythmia, clinically suspicious of myocarditis or cardiomyopathy were excluded. The research was approved by the ethics committee, and all patients signed informed consents. One-day 99 Tc m -TF G-MPI and two-day 99 Tc m -MIBI G-MPI were performed. The left ventricular functional parameters were acquired automatically by Cedars quantitative gated SPECT (QGS) software, including LVEF, EDV, ESV, peak filling rate (PFR), peak ejection rate (PER) and phase standard difference (SD). The data were analyzed using χ 2 test, two-sample t test, paired t test and linear correlation analysis by SPSS 17.0. Results: The radiochemical purities of 99 Tc m -TF and 99 Tc m -MIBI were (97.5±0.4) % and (99.1±0.2) % respectively. The coincidence rates of 99 Tc m -TF and 99 Tc m -MIBI G-MPI with CAG were 88.9% (40/45) and 90.5% (57/63), respectively. There was no significant difference between G-MPI results of the two agents (χ 2 =0.389, P>0.05). There was also no significant difference between left ventricular functional parameters of the two agents (LVEF:(62.60±13.56)% vs (60.52±7.08)%, t=0.940; EDV: (103.3±17.29) ml vs (98.52±19.37) ml, t=1.348; ESV: (41.73±12.69) ml vs (46.05±10.81) ml, t=0.851; PER: (2.73±0.67)EDV/s vs (2.61±1.04) EDV/s, t=0.725; PFR: (2.13±0.80) EDV/s vs (2.07±1.09) EDV/s, t=0.339; phase SD: (5.58±4.16)° vs (5.97±4.64)°, t=0.450; all P>0.05). There was no significant difference between left ventricular functional

  14. Tc-99m Ethylenedicysteine and Tc-99m Dimercaptosuccinic Acid Scintigraphy-Comparison of the Two for Detection of Scarring and Differential Cortical Function.

    Science.gov (United States)

    Dharmalingam, Anitha; Pawar, Shwetal U; Parelkar, Sandesh V; Shetye, Suruchi S; Ghorpade, Mangala K; Tilve, Gundu H

    2017-01-01

    The differential cortical function obtained by Tc-99m EC is comparable to that of Tc-99m DMSA. However, identification of scars on Tc-99m EC images needs to be studied. The aim of the study is to evaluate role of Tc-99m EC for detection of scarring and differential cortical function by comparing with Tc-99m DMSA. Prospective observational study of recurrent UTI; minimum 6 weeks after acute episode; when urine examination is negative for pus cells. Forty-seven children with normal positioned kidneys underwent Tc-99m EC and DMSA scintigraphy. The DRF and cortical phase images of both studies in the same image matrix size were evaluated by two independent observers for scarring; Tc-99m DMSA was considered as the gold standard. MS Excel 2007 and GraphPad Instat V3.1 and ROC analysis. There was no significant difference in the detection of scarring using two studies with Cohen's kappa coefficient (κ) 0.932. The sensitivity and specificity of Tc-99m EC for detection of scarring was 98.75% and 99.15%, respectively. There was good agreement between the differential cortical function calculated using two studies. The summed Tc-99m EC images with an acceptable high image contrast allow detection of cortical scarring in patients with normal kidney positions. It is an excellent single-modality comprehensive investigational agent for renal parenchymal defects, function, and excretion evaluation with the added advantages of lower cost, convenience, and low radiation exposure to the child.

  15. 99mTc renal tubular function agents: Current status

    International Nuclear Information System (INIS)

    Eshima, D.; Fritzberg, A.R.; Taylor, A. Jr.

    1990-01-01

    Orthoiodohippuric (OIH) acid labeled with 131I is a widely used renal radiopharmaceutical agent and has been the standard radiopharmaceutical agent for the measurement of effective renal plasma flow (EPRF). Limitations to the routine clinical use of 131I OIH are related to the suboptimal imaging properties of the 131I radionuclide and its relatively high radiation dose. 123I has been substituted for 131I; however, its high cost and short shelf-life have limited its widespread use. Recent work has centered on the development of a new 99mTc renal tubular function agent, which would use the optimal radionuclidic properties and availability of 99mTc and combine the clinical information provided by OIH. The search for a suitable 99mTc renal tubular function agent has focused on the diamide dithiolate (N2S2), the paraaminohippuric iminodiacetic acid (PAHIDA), and the triamide mercaptide (N3S) donor ligand systems. To date, the most promising 99mTc tubular function agent is the N3S complex: 99mTc mercaptoacetyltriglycine (99mTc MAG3). Studies in animal models in diuresis, dehydration, acid or base imbalance, ischemia, and renal artery stenosis demonstrate that 99mTc MAG3 behaves similarly to 131I OIH. A simple kit formulation is available that yields the 99mTc MAG3 complex in high radiochemical purity. Studies in normal subjects and patients indicate that 99mTc MAG3 is an excellent 99mTc renal tubular agent, but its plasma clearance is only 50% to 60% that of OIH. In an effort to develop an improved 99mTc renal tubular function agent, changes have been made in the core N3S donor ligand system, but to date no agent has been synthesized that is clinically superior to 99mTc MAG3. 61 references

  16. Alternative chromatographic system for the quality control of lipophilic technetium-99m radiopharmaceuticals such as [99mTc(MIBI6]+

    Directory of Open Access Journals (Sweden)

    D.P. Faria

    2015-01-01

    Full Text Available Knowledge of the radiochemical purity of radiopharmaceuticals is mandatory and can be evaluated by several methods and techniques. Planar chromatography is the technique normally employed in nuclear medicine since it is simple, rapid and usually of low cost. There is no standard system for the chromatographic technique, but price, separation efficiency and short time for execution must be considered. We have studied an alternative system using common chromatographic stationary phase and alcohol or alcohol:chloroform mixtures as the mobile phase, using the lipophilic radiopharmaceutical [99mTc(MIBI6]+ as a model. Whatman 1 modified phase paper and absolute ethanol, Whatman 1 paper and methanol:chloroform (25:75, Whatman 3MM paper and ethanol:chloroform (25:75, and the more expensive ITLC-SG and 1-propanol:chloroform (10:90 were suitable systems for the direct determination of radiochemical purity of [99mTc(MIBI6]+ since impurities such as 99mTc-reduced-hydrolyzed (RH, 99mTcO4 - and [99mTc(cysteine2]- complex were completely separated from the radiopharmaceutical, which moved toward the front of chromatographic systems while impurities were retained at the origin. The time required for analysis was 4 to 15 min, which is appropriate for nuclear medicine routines.

  17. The aerogel threshold Cherenkov detector for the high momentum spectrometer in Hall C at Jefferson lab

    International Nuclear Information System (INIS)

    Razmik Asaturyan; Rolf Ent; Howard Fenker; David Gaskell; Garth Huber; Mark Jones; David Mack; Hamlet Mkrtchyan; Bert Metzger; Nadia Novikoff; Vardan Tadevosyan; William Vulcan; Stephen Wood

    2004-01-01

    We describe a new aerogel threshold Cherenkov detector installed in the HMS spectrometer in Hall C at Jefferson Lab. The Hall C experimental program in 2003 required an improved particle identification system for better identification of π/K/p, which was achieved by installing an additional threshold Cherenkov counter. Two types of aerogel with n = 1.03 and n = 1.015 allow one to reach ∼10 -3 proton and 10 -2 kaon rejection in the 1-5 GeV/c momentum range with pion detection efficiency better than 99% (97%). The detector response shows no significant position dependence due to a diffuse light collection technique. The diffusion box was equipped with 16 Photonis XP4572 PMT's. The mean number of photoelectrons in saturation was ∼16 and ∼8, respectively. Moderate particle identification is feasible near threshold

  18. Quality assurance of Mo-99/Tc-99m radionuclide generators

    Science.gov (United States)

    Uzunov, Nikolay; Yordanova, Galina; Salim, Seniha; Stancheva, Natalya; Mineva, Vanya; Meléndez-Alafort, Laura; Rosato, Antonio

    2018-03-01

    Gamma-ray spectrometry analyses of the radionuclide content of eluate from two Mo-99/Tc-99m radionuclide generators POLTECHNET have been performed. The relative activities of 99Mo 103Ru and 131I radioisotopes with respect to the activity of 99mTc at different time intervals after the primary pertechnetate elution of the generators have been analyzed. The relative activities of the isotopes were determined and compared to the radionuclidic purity requirements for 99mTc.

  19. Realistic Realizations Of Threshold Circuits

    Science.gov (United States)

    Razavi, Hassan M.

    1987-08-01

    Threshold logic, in which each input is weighted, has many theoretical advantages over the standard gate realization, such as reducing the number of gates, interconnections, and power dissipation. However, because of the difficult synthesis procedure and complicated circuit implementation, their use in the design of digital systems is almost nonexistant. In this study, three methods of NMOS realizations are discussed, and their advantages and shortcomings are explored. Also, the possibility of using the methods to realize multi-valued logic is examined.

  20. Molybdenum-99/technetium-99M generators

    International Nuclear Information System (INIS)

    Morcos, N.A.; Bruno, G.A.; Haney, T.A.

    1981-01-01

    A 99 Mo/sup(99m)Tc generator is described which has an alumina support medium consisting of multiple beds of controlled pH and in which no bed has a pH value higher than the bed preceding it. It is claimed that by using this method low yield problems of such generators can be mitigated. (U.K.)

  1. Precision measurement of the top quark mass at threshold with the FCC-ee

    CERN Document Server

    Foppiani, Nicolo

    2016-01-01

    The project concerns the study of the sensitivity in measuring the Top quark mass at threshold at the FCC-ee, using a Montecarlo analysis. In particular it has been developed within the FCC software framework, using a fast simulation. The work focused firstly on developing a b-tagging algorithm inside of the FCC fast simulation, managing to obtain results comparable with the ALEPH ones, and new results with a futuristic detector like ILD. Afterwards the selection of the tt events at energy close to the pair production threshold has been studied, obtaining a selection efficiency of 55 % and a background rejection at the level of 99.4 %. In the end, a list of points that can be achieved in the future, to complete the analysis, has been identified.

  2. Generators of 99Mo-99mTc

    International Nuclear Information System (INIS)

    Robles, A.M.

    1994-01-01

    Between the radioisotopes family pairs we find the 99 Molibdenum - 99m technetium pairs. Such as isotope production,decay and chemical toxic, humid and dry generators,radiation protection handling practice and blinding had been sudied in this work.Tabs

  3. Development of 99Mo/99mTc Generator System for Production of Medical Radionuclide 99mTc using a Neutron-activated 99Mo and Zirconium Based Material (ZBM as its Adsorbent

    Directory of Open Access Journals (Sweden)

    I. Saptiama

    2016-12-01

    Full Text Available Molybdenum produced from fission of U-235 is the most desirable precursor for 99Mo/99mTc generator system as it is non-carrier added and has high specific activity. However, in the last decade there has been short supply of 99Mo due to several constrains. Therefore, there have been many works performed for development of 99Mo/99mTc generator system using 99Mo which is not produced from either LEU or HEU. This report deals with development of 99Mo/99mTc generator system where zirconium-based material (ZBM is used as adsorbent of neutron-activated 99Mo. The system was prepared by firstly irradiating natural Mo in the G. A. Siwabessy reactor to produce neutron-activated 99Mo. The target was dissolved in NaOH 4N and then neutralized with 12 M HCl. The 99Mo solution was then mixed with a certain amount of ZBM followed by heating at 90°C for three hours to allow the 99Mo adsorbed on ZBM. The 99Mo-ZBM (9.36 GBq of 99Mo was Mo/ 4.2 g ZBM was packed on a fritz-glass column. This column was then fitted serially with an alumina column for trapping 99Mo breakthrough. The columns were then eluted daily with saline solution for up to one week. The yield of 99mTc was found to be between 53.7 – 74% (n= 5. All 99mTc eluates were clear solutions with pH of 5. Breakthrough of 99Mo in 99mTc eluates was found to be 0.031 ± 0.019 μCi 99Mo/ mCi 99mTc (n= 5 which was less than the maximum activity of 99Mo allowed in 99mTc solution ( 99%. Radiolabeling of this 99mTc towards methylene diphosphonate (MDP kit gave a radiolabelling efficiency of 99%. In summary, a new 99Mo/99mTc generator system that used neutron-activated 99Mo and ZBM as its adsorbent has been successfully prepared. The 99mTc produced from this new 99Mo/99mTc generator system attained the quality of 99mTc required for medical purposes.

  4. 22 CFR 96.99 - Converting an application for temporary accreditation to an application for full accreditation.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Converting an application for temporary accreditation to an application for full accreditation. 96.99 Section 96.99 Foreign Relations DEPARTMENT OF... INTERCOUNTRY ADOPTION ACT OF 2000 (IAA) Procedures and Standards Relating to Temporary Accreditation § 96.99...

  5. Behavior of technetium-99 in soils and plants. Progress report, April 1, 1974--March 31, 1977

    International Nuclear Information System (INIS)

    Gast, R.G.; Landa, E.R.; Thorvig, L.J.

    1976-12-01

    Studies described in this report were aimed at establishing the magnitude and mechanisms of 99 Tc sorption by soils and uptake by plants. Results show that 99 Tc was sorbed from solution over a period of two to five weeks by 8 of 11 soils studied. The slow rate of sorption, the lack of sorption by low organic matter soils, the elimination of sorption following sterilization and increased sorption following addition of dextrose all point to a microbial role in the sorption process. However, it has not been established whether this is a direct or indirect role nor is it possible to clearly predict the conditions under which sorption will occur. Results of plant uptake studies show that 99 Tc can be taken up and translocated into the photosynthetic tissue of higher plants with concentrations in seeds being much less than in vegetative tissue. Technetium-99 was also shown to be toxic to plants at low concentrations and evidence suggests that this is a chemically rather than a radiologically induced toxicity. However, this remains to be completely resolved, as well as whether there is a threshold level of 99 Tc required before toxicity occurs

  6. (99m)Tc-HYNIC-TOC scintigraphy in evaluation of active Graves' ophthalmopathy (GO).

    Science.gov (United States)

    Sun, Hua; Jiang, Xu-Feng; Wang, Shu; Chen, Hao-Yan; Sun, Jiao; Li, Pei-Yong; Ning, Guang; Zhao, Yong-Ju

    2007-06-01

    A promising radiopharmaceutical (99m)Tc-HYNIC-TOC ((99m)Tc-HYNIC-Octreotide) can be applied for somatostatin receptor scintigraphy with the potential to replace Indium-111 labeled somatostatin analogus. Here we evaluate whether orbital (99m)Tc-HYNIC-TOC scintigraphy can be used as a Graves' ophthalmopathy (GO) activity parameter to predict the retrobulbar irradiation response. Orbital (99m)Tc-HYNIC-TOC scintigraphy was performed on 14 consecutive patients demonstrating moderated to severe Graves' ophthalmopathy. The patients were treated with retrobulbar irradiation following the octreoscan and the response to this therapy was assessed at 3 months after the start of treatment. The orbital (99m)Tc-HYNIC-TOC uptake was calculated to assess the effects of treatment. Among the 14 GO patients, eight (57.1%) responded to retrobulbar radiotherapy; six (42.9%) showed no change. We compared the eight responders and six non-responders in terms of orbital (99m)Tc-HYNIC-TOC uptake, using the orbital/occipital ratio. On the 4-h (99m)Tc-HYNIC-TOC scintigraphy, responders had a higher orbital/occipital uptake ratio than the no-responders (P = 0.001). A significant correlation was found between the orbital/occipital ratio and the clinical activity score (CAS) (P = 0.034). The Receiving-Operator-Characteristic curve showed the best threshold for discriminating active and inactive disease was 1.40 (sensitivity, 100%; specificity, 83.3%). In the responders group, all these eight patients had positive scintigraphy. While there were five patients who had negative scintigraphy in the non-responders group. Orbital (99m)Tc-HYNIC-TOC scintigraphy can be a useful method for the estimation of disease activity and prediction the response to subsequent radiotherapy in GO patient. And the patients with positive octreoscan were more likely to respond to irradiation.

  7. The new 99mTc myocardial perfusion imaging agents: 99mTc-sestamibi and 99mTc-teboroxime

    International Nuclear Information System (INIS)

    Berman, D.S.; Kiat, H.; Maddahi, J.

    1991-01-01

    The two new 99m (99mTc) labeled myocardial perfusion agents, 99mTc-Sestamibi and 99mTc-Teboroxime, are now available for routine clinical application. Both agents allow assessment of ejection fraction by the first-pass technique at rest or during exercise, thus providing additional information not available with thallium-201. 99mTc-Sestamibi has long myocardial residence time, as well as adequate myocardial extraction, providing images of higher count density and superior quality compared with thallium-201. 99mTc-Teboroxime has excellent myocardial uptake characteristics but is cleared very rapidly from the myocardium. Both tracers have shown results similar to those obtained with thallium-201 for detection of coronary artery disease and the assessment of defect reversibility. 99mTc-Sestamibi studies using the rest/stress imaging sequence can be accomplished in approximately 5 hours; studies using dual-isotope imaging (rest thallium-201 and stress 99mTc-Sestamibi injection) can be completed in 1 to 2 hours. Gated stress images can be performed with 99mTc-Sestamibi, providing simultaneous information of myocardial perfusion at stress and resting wall motion or thickening and allowing rapid differentiation of ischemic from infarcted tissue. Because of its slow myocardial clearance and absence of redistribution, 99mTc-Sestamibi allows uncoupling of the time of injection from the time of imaging and thus can be valuable in the evaluation of acute myocardial infarction and outcome of thrombolytic therapy. With 99mTc-Teboroxime, rapid serial studies are feasible. Pharmacologic stress and rest studies with 99mTc-Teboroxime single photon emission computed tomography potentially can be completed in under 30 minutes. 73 references

  8. Computational analysis of thresholds for magnetophosphenes

    International Nuclear Information System (INIS)

    Laakso, Ilkka; Hirata, Akimasa

    2012-01-01

    In international guidelines, basic restriction limits on the exposure of humans to low-frequency magnetic and electric fields are set with the objective of preventing the generation of phosphenes, visual sensations of flashing light not caused by light. Measured data on magnetophosphenes, i.e. phosphenes caused by a magnetically induced electric field on the retina, are available from volunteer studies. However, there is no simple way for determining the retinal threshold electric field or current density from the measured threshold magnetic flux density. In this study, the experimental field configuration of a previous study, in which phosphenes were generated in volunteers by exposing their heads to a magnetic field between the poles of an electromagnet, is computationally reproduced. The finite-element method is used for determining the induced electric field and current in five different MRI-based anatomical models of the head. The direction of the induced current density on the retina is dominantly radial to the eyeball, and the maximum induced current density is observed at the superior and inferior sides of the retina, which agrees with literature data on the location of magnetophosphenes at the periphery of the visual field. On the basis of computed data, the macroscopic retinal threshold current density for phosphenes at 20 Hz can be estimated as 10 mA m −2 (−20% to  + 30%, depending on the anatomical model); this current density corresponds to an induced eddy current of 14 μA (−20% to  + 10%), and about 20% of this eddy current flows through each eye. The ICNIRP basic restriction limit for the induced electric field in the case of occupational exposure is not exceeded until the magnetic flux density is about two to three times the measured threshold for magnetophosphenes, so the basic restriction limit does not seem to be conservative. However, the reasons for the non-conservativeness are purely technical: removal of the highest 1% of

  9. CARA Risk Assessment Thresholds

    Science.gov (United States)

    Hejduk, M. D.

    2016-01-01

    Warning remediation threshold (Red threshold): Pc level at which warnings are issued, and active remediation considered and usually executed. Analysis threshold (Green to Yellow threshold): Pc level at which analysis of event is indicated, including seeking additional information if warranted. Post-remediation threshold: Pc level to which remediation maneuvers are sized in order to achieve event remediation and obviate any need for immediate follow-up maneuvers. Maneuver screening threshold: Pc compliance level for routine maneuver screenings (more demanding than regular Red threshold due to additional maneuver uncertainty).

  10. 99Mo-99mTc production development by (n, γ) reaction

    International Nuclear Information System (INIS)

    Izumo, Hironobu; Nishikata, Kaori; Kimura, Akihiro; Tanimoto, Masataka; Tsuchiya, Kunihiko; Ishihara, Masahiro; Kaminaga, Masanori

    2012-01-01

    The renewed JMTR will be started from the later half of JFY2012, and it is expected to various fields. Supply of 99 Mo in Japan depends only on imports from foreign countries. JAEA has a plan to produce 99 Mo, a parent nuclide of 99m Tc. JMTR will contribute to produce 99 Mo by (n, r) method as one of effective uses of the JMTR. In this paper, outline of the technical study items for production method of 99 Mo- 99m Tc in JMTR will be described. (author)

  11. A modified {sup 99} Mo- {sup 99} Tc generator on Zirconium molybdo- phosphate-{sup 99} Mo gel. Vol. 3

    Energy Technology Data Exchange (ETDEWEB)

    El-Kolaly, M T; Talaat, H [Labelled Compounds Department, Cairo (Egypt); Botros, N [Radioistspe and Generator Department, Radioisotope Production and Sealed Source Division, Hot Laboratories Center, Atomic Energy Authority, Cairo (Egypt)

    1996-03-01

    A modified {sup 99} Mo - {sup 99} Tc gel generator is described. The new generator is based on the use of zirconium molybdophosphate - {sup 99} Mo gel in which {sup 99} Mo chemically combined in the gel structure, where {sup 99m}Tc can be easily eluted with distilled water or saline. The gel was prepared via chemical reaction between zirconyl chloride and molybdophosphate - {sup 99} Mo solution. The PH of the reaction mixture was adjusted with NaOH. Different gels have been prepared by varying the molar ratio of Mo:Zr:p. The PH and time of digeston on complete gel formation was also investigated in order to optimize the condition of gel preparation. Molybdophosphate {sup 32} P solution was used to determine the phosphorous content in the gel and in the {sup 99m}Tc eluate. The temperature and time of drying of the gel and their effect on {sup 99m}Tc elution efficiency were also studied. From the data obtained, the optimum conditions for routine production of {sup 99} Mo - {sup 99m}Tc generator are presented and discussed. 2 figs., 6 tabs.

  12. Concentration of sup(99m)Tc from the eluate of 99Mo-sup(99m)Tc generators

    International Nuclear Information System (INIS)

    Saucedo, T.; Mora, M.; Fraga de Suarez, A.H.; Mitta, A.E.A.

    1976-04-01

    A method is described to concentrate sup(99m)Tc solutions, originated in 99 Mo-sup(99m)Tc generators, independent of its age. The techniques of preparation of the different radiopharmaceuticals used in nuclear medicine are also described. (author) [es

  13. Problems in clinical practice of domestic supply of 99Mo/99mTc. Considerations on the domestic production of 99Mo/99mTc

    International Nuclear Information System (INIS)

    Yamabayashi, Hisamichi

    2012-01-01

    At present, a bulky import product, 99 Mo supplied in Japan is produced by a nuclear fission method which enables to produce a generator system with no need of commercially preparing 99m Tc-labeled radiopharmaceuticals due to its high specific activity. However its usage of enriched uranium target leads to avoiding the fission method from the option of domestic production. In order to secure the domestic supply of 99 Mo/ 99m Tc, the neutron activation method, aiming to meet about 20% of domestic demand, is under development along with the re-start program of JMTR. Development of various production methods using accelerators are also in progress. In those non-fission methods with reactors or accelerators, rapid and effective procedures for concentration and refinement of 99m Tc solution eluted from 99 Mo of low specific activity are the subjects to be considered for attaining the stable labeling performances. (author)

  14. Technetium-99m scintimammography in the diagnosis of malignant breast tumors

    Directory of Open Access Journals (Sweden)

    Jauković Ljiljana

    2004-01-01

    Full Text Available Background. Technetium-99m (99mTc tetrofosmin scintigraphy is a new imaging method for the diagnosis of various malignancies, such as lung, thyroid, and most frequently breast neoplasms. The aim of this study was to evaluate the diagnostic reliability of 99mTc-Tetrofosmin breast scintigraphy in the detection of malignant breast disease. Methods. 99mTc -Tetrofosmin scintimammography (SMM was performed in 28 patients with 30 breast lesions suspicious for malignancy. Standard mammography (MM was also done. After surgery, the results of SMM and MM were compared to definitive histopathological findings as the "gold standard". After intravenous injection of radiotracer, SMM was performed in prone and supine views of the thorax, using large field-of-view Gamma camera. Results. The results of SMM were interpreted visually and semiquantitatively, and evaluated as positive or negative. Sensitivity, specificity and accuracy, positive (PPV and negative predictive value (NPV were obtained in relation to histopathology. After comparing the results of SMM and MM, SMM was proved more sensitive (95% for SMM vs. 80% for MM, while the specificity of both methods was similar. Conclusion. The results of this study indicate that the contribution of SMM as a nuclear medicine procedure has its place in the diagnostic protocol for patients suspected of malignant breast cancer.

  15. A Comparison of the Cluster-Span Threshold and the Union of Shortest Paths as Objective Thresholds of EEG Functional Connectivity Networks from Beta Activity in Alzhaimer’s Disease

    OpenAIRE

    Smith, K; Abasolo, Daniel Emilio; Escudero, J

    2016-01-01

    The Cluster-Span Threshold (CST) is a recently introduced unbiased threshold for functional connectivity networks. This binarisation technique offers a natural trade-off of sparsity and density of information by balancing the ratio of closed to open triples in the network topology. Here we present findings comparing it with the Union of Shortest Paths (USP), another recently proposed objective method. We analyse standard network metrics of binarised networks for sensitivity to clinical Alzhei...

  16. Gain optimization in fiber optical parametric amplifiers by combining standard and high-SBS threshold highly nonlinear fibers

    DEFF Research Database (Denmark)

    Da Ros, Francesco; Rottwitt, Karsten; Peucheret, Christophe

    2012-01-01

    Combining Al-doped and Ge-doped HNLFs as gain media in FOPAs is proposed and optimized, resulting in efficient SBS mitigation while circumventing the additional loss of the high SBS threshold Al-doped fiber.......Combining Al-doped and Ge-doped HNLFs as gain media in FOPAs is proposed and optimized, resulting in efficient SBS mitigation while circumventing the additional loss of the high SBS threshold Al-doped fiber....

  17. Labelled Preformed liposomes with 99MTC-DTPA, 99 MTC-ECD, 99MTC-MDP and 99MTC-MIBI : Labelling procedures and stability studies

    International Nuclear Information System (INIS)

    Savio, E.O.; Teran, M.A.; Vales, M.E.; Frier, M.

    2004-01-01

    Liposomes labelled with gamma e miters like 99mTc, can be used for scintigraphic imaging to non-invasively track and quantify the distribution of liposomes in the body. In vitro studies were done to choose a suitable radiopharmaceutical (RF) to be attached to performed liposomes. 99mTc-Complexes (DTPA, ECD, MDP, MIBI) were used to label collagen liposomes. Commercial kits were labelled with 99mTc04-(TechnoNuclear). Quality controls of the RF were performed. Collagen liposomes suspended in saline 0.9% were incubated at 4.25.37 and 60 for 30 min. Efficiency of the labelling procedure was determined by gel filtration using Sephadex G25 (Pharmacia) and NaC10.9%. Samples of 100mL (74MBq), were seeded and fractions of 0.5mL were colleted and measured in an ionisation chamber (Capintec CRC). Stability of the labelled liposomes was assessed incubating 0.5mL, of the suspension with 1mL of human serum during 30 min at 37 . Dialysis was performed using dialysis bags of 64 K pore size and NaCI 0.9% at room temperature. Samples of the saline bath were collected at 30.60 and 90 min. and measured in a solid scintillation counter Ortec.Liposomes labelled with 99mTc-DTPA and 99mTcMIBI showed a labelling efficiency of 80%; liposomes incubated with 99mTc-MDP were labelled in a 50% and 99mTc-ECD did not bind to liposomes in the conditions of study. Incubation of labelled liposomes with human serum showed 50% of strong binding to the plasmatic proteins for 99mTc-DTPA but low values (5%) for the other specimens. Labelled liposomes were achieved, with different RF, showing a suitable in vitro stability to perform in vivo studies

  18. Comparative study of 99Mo/99mTc generators at base of synthesized gels starting from activation and fission 99Mo

    International Nuclear Information System (INIS)

    Lopez M, I.Z.; Monroy G, F.; Rivero G, T.; Rojas N, P.

    2007-01-01

    The 99m Tc is used for diagnostic and therapy. It is produced starting from 99 Mo, absorbed in chromatographic columns, loaded with alumina that absorb only 0.2% of 99 Mo with high specific activities of 99 Mo, obtained from the 235 U fission. Given these conditions and limitations, new preparation procedures of 99 Mo/ 99m Tc generators, its have been developed, using zirconium molybdates gels that incorporates until 30% of 99 Mo, conserve similar characteristics of quality and purity that the traditional generator. The radiochemical characteristics of the 99m Tc elution, depend strongly on the gel preparation conditions. In particular, the present work has by object to determine the influence of the 99 Mo used type, fission or activation product, during the gels synthesis, as well as the used air flow for the agitation in the gels preparation and its influence in the 99 Mo/ 99m Tc generators quality. When diminishing the flow of agitation air the efficiency it increases and in the radionuclide purity of the eluates and when using 99 Mo from fission for the gels production it increases in an important way the elutriation efficiency, the radiochemical and radionuclide purity of the 99m Tc eluates. (Author)

  19. Measurement of technetium-99 in soil samples collected in Marshall Islands

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, K.; Uchida, S. [National Inst. of Radiological Sciences, Environmental and Toxicological Sciences Research Group, Chiba (Japan)

    2000-07-01

    Extraction techniques for recovery of technetium-99 ({sup 99}Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for {sup 99}Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the {sup 99}Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The {sup 99}Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for {sup 99}Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  20. Measurement of technetium-99 in soil samples collected in Marshall Islands

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.

    2000-01-01

    Extraction techniques for recovery of technetium-99 ( 99 Tc) for ICP-MS measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99 Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99 Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99 Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq/g-dw. The limit of detection for 99 Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq/g-dw under standard operating conditions. (author)

  1. Gaps-in-Noise test: gap detection thresholds in 9-year-old normal-hearing children.

    Science.gov (United States)

    Marculino, Carolina Finetti; Rabelo, Camila Maia; Schochat, Eliane

    2011-12-01

    To establish the standard criteria for the Gaps-in-Noise (GIN) test in 9-year-old normal-hearing children; to obtain the mean gap detection thresholds; and to verify the influence of the variables gender and ear on the gap detection thresholds. Forty normal-hearing individuals, 20 male and 20 female, with ages ranging from 9 years to 9 years and 11 months, were evaluated. The procedures performed were: anamnesis, audiological evaluation, acoustic immittance measures (tympanometry and acoustic reflex), Dichotic Digits Test, and GIN test. The results obtained were statistically analyzed. The results revealed similar performance of right and left ears in the population studied. There was also no difference regarding the variable gender. In the subjects evaluated, the mean gap detection thresholds were 4.4 ms for the right ear, and 4.2 ms for the left ear. The values obtained for right and left ear, as well as their standard deviations, can be used as standard criteria for 9-year-old children, regardless of ear or gender.

  2. Labelling and quality control of 99mTc labelled somatostatin analogues

    International Nuclear Information System (INIS)

    Poramatikul, N.; Sangsuriyan, J.; Kongpeth, P.; Ngamprayad, T.; Laloknam, S.; Permtermsin, C.; Madsomboon, N.

    2001-01-01

    To standardize interlaboratory reproducibility, iodination of RC-160 with 125 I and direct labelling of RC-160 with 99m Tc, quality control and binding assay were performed. Two conjugated peptides, HYNIC-RC-160 and MAG-3-RC-160, were synthesized. The conjugated peptides were radiolabelled with 99m Tc via co-ligands; 99m Tc-MAG-3-RC-160 via glucoheptonate, 99m Tc-HYNIC-RC-160 via EDDA and tricine. Conditions for labelling were optimized. Analytical and purification methods for the labelled products were developed. Radiochemical purity test of 99m Tc labelled peptides was performed by HPLC with gradient elution of 0.1%TFA/water and acetonitrile, or by ITLC-SG in saline and in 50% acetonitrile. The contaminants in 99m Tc radiolabelled product were separated by elution from SEPPAK C-18 cartridge by 0.1% acetic acid and the pure product was eluted out of SEPPAK column by 50% acetonitrile with about 68% recovery. Stability of the purified 99m Tc-MAG3-RC-160 stored at -20 deg. C was more than 72 h. 99m Tc-MAG-3-RC-160 showed a high equilibrium dissociation constant with K D of 26 pmole/mg protein and B max of 7.9 mM. (author)

  3. Gentc99m, computational system for the technetium-99m generator

    International Nuclear Information System (INIS)

    Suparman, I.

    1997-01-01

    The technetium-99m generator is one of the main products of the PPR, as the continuity of the technetium-99m generator production is important for supporting the development of nuclear medicine. GENTC99M has been made for computational for the technetium-99m generator and includes data processing, documentation and information GENTC99M is also very useful in quality control application especially for the determinations of yield and radionuclidic impurities which consume much time. microsoft visual basic for MS-DOS and visual basic for windows have been used for making GENTC99M. Microsoft visual basic has several features that make it an ideal development language for both MS-DOS and Microsoft Windows. These features not only increase productivity, they also provide all the tools and hooks needed to develop some very sophisticated applications. for a production centre like PPR, GENTC99M is very useful to support the data processing, documentation and information system of the technetium-99m generator and it can also be modified for other products

  4. Theory of threshold phenomena

    International Nuclear Information System (INIS)

    Hategan, Cornel

    2002-01-01

    Theory of Threshold Phenomena in Quantum Scattering is developed in terms of Reduced Scattering Matrix. Relationships of different types of threshold anomalies both to nuclear reaction mechanisms and to nuclear reaction models are established. Magnitude of threshold effect is related to spectroscopic factor of zero-energy neutron state. The Theory of Threshold Phenomena, based on Reduced Scattering Matrix, does establish relationships between different types of threshold effects and nuclear reaction mechanisms: the cusp and non-resonant potential scattering, s-wave threshold anomaly and compound nucleus resonant scattering, p-wave anomaly and quasi-resonant scattering. A threshold anomaly related to resonant or quasi resonant scattering is enhanced provided the neutron threshold state has large spectroscopic amplitude. The Theory contains, as limit cases, Cusp Theories and also results of different nuclear reactions models as Charge Exchange, Weak Coupling, Bohr and Hauser-Feshbach models. (author)

  5. Threshold network of a financial market using the P-value of correlation coefficients

    Science.gov (United States)

    Ha, Gyeong-Gyun; Lee, Jae Woo; Nobi, Ashadun

    2015-06-01

    Threshold methods in financial networks are important tools for obtaining important information about the financial state of a market. Previously, absolute thresholds of correlation coefficients have been used; however, they have no relation to the length of time. We assign a threshold value depending on the size of the time window by using the P-value concept of statistics. We construct a threshold network (TN) at the same threshold value for two different time window sizes in the Korean Composite Stock Price Index (KOSPI). We measure network properties, such as the edge density, clustering coefficient, assortativity coefficient, and modularity. We determine that a significant difference exists between the network properties of the two time windows at the same threshold, especially during crises. This implies that the market information depends on the length of the time window when constructing the TN. We apply the same technique to Standard and Poor's 500 (S&P500) and observe similar results.

  6. The threshold of cortical electrical stimulation for mapping sensory and motor functional areas.

    Science.gov (United States)

    Guojun, Zhang; Duanyu, Ni; Fu, Paul; Lixin, Cai; Tao, Yu; Wei, Du; Liang, Qiao; Zhiwei, Ren

    2014-02-01

    This study aimed to investigate the threshold of cortical electrical stimulation (CES) for functional brain mapping during surgery for the treatment of rolandic epilepsy. A total of 21 patients with rolandic epilepsy who underwent surgical treatment at the Beijing Institute of Functional Neurosurgery between October 2006 and March 2008 were included in this study. Their clinical data were retrospectively collected and analyzed. The thresholds of CES for motor response, sensory response, and after discharge production along with other threshold-related factors were investigated. The thresholds (mean ± standard deviation) for motor response, sensory response, and after discharge production were 3.48 ± 0.87, 3.86 ± 1.31, and 4.84 ± 1.38 mA, respectively. The threshold for after discharge production was significantly higher than those of both the motor and sensory response (both pstimulation frequency of 50 Hz and a pulse width of 0.2 ms, the threshold of sensory and motor responses were similar, and the threshold of after discharge production was higher than that of sensory and motor response. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Thermochemical studies on two alkyl-bulky substituted xanthene derivatives: 9,9-dimethylxanthene and 2,7-di-tert-butyl-9,9-dimethylxanthene

    International Nuclear Information System (INIS)

    Freitas, Vera L.S.; Gomes, José R.B.; Ribeiro da Silva, Maria D.M.C.

    2017-01-01

    Highlights: • Energetic characterization of two alkyl-bulky substituted xanthene derivatives. • Massic energies of combustion of xanthene derivatives. • Enthalpies of sublimation determined by vacuum drop microcalorimetry technique. • Temperature-vapour pressure dependence by mass-loss Knudsen effusion method. • Gas-phase enthalpies of formation of alkyl xanthene derivatives. - Abstract: Thermodynamic properties of 9,9-dimethylxanthene and 2,7-di-tert-butyl-9,9-dimethylxanthene for the condensed and gas states were derived from experimental and computational studies. Static-bomb combustion calorimetry, vacuum drop microcalorimetry and the Knudsen effusion techniques were used. Computational calculations of the enthalpies of hypothetical reactions in the gaseous phase, using the G3(MP2)//B3LYP composite method, were performed for the two xanthene derivatives. Natural bond orbital (NBO) calculations were also performed to ascertain the structure and reactivity of these compounds. The energetic effects caused by replacing hydrogen atoms in the xanthene moiety by methyl and tert-butyl groups yielding 9,9-dimethylxanthene and 2,7-di-tert-butyl-9,9-dimethylxanthene species were determined from direct comparison of their standard (p o = 0.1 MPa) molar enthalpies of formation in the gaseous phase, at T = 298.15 K.

  8. Threshold enhancement of diphoton resonances

    CERN Document Server

    Bharucha, Aoife; Goudelis, Andreas

    2016-10-10

    The data collected by the LHC collaborations at an energy of 13 TeV indicates the presence of an excess in the diphoton spectrum that would correspond to a resonance of a 750 GeV mass. The apparently large production cross section is nevertheless very difficult to explain in minimal models. We consider the possibility that the resonance is a pseudoscalar boson $A$ with a two--photon decay mediated by a charged and uncolored fermion having a mass at the $\\frac12 M_A$ threshold and a very small decay width, $\\ll 1$ MeV; one can then generate a large enhancement of the $A\\gamma\\gamma$ amplitude which explains the excess without invoking a large multiplicity of particles propagating in the loop, large electric charges and/or very strong Yukawa couplings. The implications of such a threshold enhancement are discussed in two explicit scenarios: i) the Minimal Supersymmetric Standard Model in which the $A$ state is produced via the top quark mediated gluon fusion process and decays into photons predominantly through...

  9. Mismatched uptake of Tc-99m-ECD and Tc-99m-HMPAO in subacute cerebral infarction: Tc-99m-ECD for viability and Tc-99m-HMPAO for flow restoration

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D. S.; Hyun, I. Y.; Kim, S. K. [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)] [and others

    1997-07-01

    Tc-99m-HMPAO reflects tissue perfusion but Tc-99m-ECD uptake is affected by tissue viability in addition to tissue perfusion which the varied state of cellular retention of Tc-99m-ECD reflects. Luxuriously perfused area on Tc-99m-HMPAO SPECT implies that this cortex was already reperfused either spontaneously or after thrombolysis and that accompanied paralysis of vascular reactivity in those zones warms progressive deterioration. We tried to find out if we can use sequential Tc-99m-ECD/Tc-99m-HMPAO SPECT to reveal cortical perfusion and severity and range of risky areas of cerbral cortex despite reperfusion in sub-acute infarction. In 13 patients (M ; F =7 : 6, mean age 57 (range: 26-84)) with cortical (n=12) and basal ganglia infarction (1), we performed sequential Tc-99m-ECD/Tc-99m-HMPAO SPECT at the same position. At first, 555 MBq of Tc-99m-ECD was injected and imaged and then 1110 MBq of Tc-99m-HMPAO was injected again and imaged with the patients in situ, and the first image (Tc-99m-ECD) and the subtracted image (2nd- 1st : Tc-99m-HMPAO) were compared slice by slice. Study was done from 3 days to 31 days (16{+-}9) after ictus. Tc-99m-ECD uptake was always less than or equal to Tc-99m-HMPAO uptake at the lesion in all cases. Luxury perfusion was prominent in four patients. Mismatched uptake was found in 10 patients. Severity of mismatch showed diverse spectrum and was ranged from total middle cerebral artery territory (1 case) to peripheral thin zones around infarction (2 cases). The other 7 showed intermediate amount of tissues with mismatch , i.e., Tc-99m-ECD defects where Tc-99m-HMPAO uptake is in part increased, normal or decreased. Upon discharge, patients having more uptake with Tc-99m-ECD predicted improvement. Patients having mismatched uptake went dichotomous way. In conclusion, Tc-99m-ECD/Tc-99m-HMPAO sequential SPECT is feasible and reveal both tissue perfusion (Tc-99m-HMPAO ) and discrepant Tc-99m-ECD uptake probably reflecting viability in acute

  10. Pain assessment in patellar tendinopathy using pain pressure threshold algometry: : An observational study

    NARCIS (Netherlands)

    Kregel, Jeroen; van Wilgen, Cornelis Paul; Zwerver, Johannes

    ObjectiveAssessing pain in patellar tendinopathy (PT) is difficult to perform in a standardized way. With this study, we measured pain in athletes with PT by means of pain pressure threshold (PPT) algometry in a standardized manner. Subsequently, the goal of this study is to determine normative

  11. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    International Nuclear Information System (INIS)

    Moselewski, Fabian; Ferencik, Maros; Achenbach, Stephan; Abbara, Suhny; Cury, Ricardo C.; Booth, Sarah L.; Jang, Ik-Kyung; Brady, Thomas J.; Hoffmann, Udo

    2006-01-01

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 ± 68.7 HU versus 295 ± 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT

  12. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moselewski, Fabian [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Ferencik, Maros [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Achenbach, Stephan [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Internal Medicine II (Cardiology), University of Erlangen (Germany); Abbara, Suhny [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Booth, Sarah L. [Jean Mayer USDA Human Nutrition Research Center on Aging, 711 Washington St., Boston, MA 02114 (United States); Jang, Ik-Kyung [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Brady, Thomas J. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)]. E-mail: uhoffman@partners.org

    2006-03-15

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM] at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 {+-} 68.7 HU versus 295 {+-} 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.

  13. Materiality Thresholds in Accounting and Auditing Some UK Evidence

    OpenAIRE

    Chong, Gin

    2000-01-01

    This paper reports the telephone interviews with 12 auditors (Big 5 and non Big 5) and 14 non auditors on the materiality thresholds adopted by them or by their organisations. Non auditors include from finance directors, banker, lawyer, internal auditors, an academic, and technical directors of the Accounting Standards Board (ASB) and the Auditing Practices Board (APB) in the UK. This is in respond to the issuance of Statement of Auditing Standards (SAS) 220 on ‘Materiality and the Audit= by t...

  14. Preparation of 99Mo/99mTc generators based on 99Mo zirconium molybdates in the Gel Synthesis Device for Generators

    International Nuclear Information System (INIS)

    Lopez M, I. Z.; Monroy G, F.; Rivero G, T.; Rojas N, P.

    2008-01-01

    The 99m Tc is used for diagnosis and therapy. It is produced commercially from 99 Mo obtained from the fission of 235 U, which is retained in chromatographic columns filled with alumina whose maximum capacity is 0.2%. Given these constraints new methods of preparation 99 Mo/ 99m Tc generators have been developed using zirconium molybdates gels containing up to 30% of Mo, which is part of the generator matrix, and retaining quality and purity similar characteristics to those commercial generators. The present study aims to determine the flow of agitation, temperature and drying time optimal to prepare 99 Mo/ 99m Tc generators based on 99 Mo zirconium molybdates in the Gel Synthesis Device 99 Mo/ 99m Tc Generators designed and built by groups of the Radioactive Materials Research Laboratory and Automation and Instrumentation Department of the National Institute of Nuclear Research. (Author)

  15. Molecular sensitivity threshold of wet mount and an immunochromatographic assay evaluated by quantitative real-time PCR for diagnosis of Trichomonas vaginalis infection in a low-risk population of childbearing women.

    Science.gov (United States)

    Leli, Christian; Castronari, Roberto; Levorato, Lucia; Luciano, Eugenio; Pistoni, Eleonora; Perito, Stefano; Bozza, Silvia; Mencacci, Antonella

    2016-06-01

    Vaginal trichomoniasis is a sexually transmitted infection caused by Trichomonas vaginalis, a flagellated protozoan. Diagnosis of T. vaginalis infection is mainly performed by wet mount microscopy, with a sensitivity ranging from 38% to 82%, compared to culture, still considered the gold standard. Commercial immunochromatographic tests for monoclonal-antibody-based detection have been introduced as alternative methods for diagnosis of T. vaginalis infection and have been reported in some studies to be more sensitive than wet mount. Real-time PCR methods have been recently developed, with optimal sensitivity and specificity. The aim of this study was to evaluate whether there is a molecular sensitivity threshold for both wet mount and imunochromatographic assays. To this aim, a total of 1487 low-risk childbearing women (median age 32 years, interquartile range 27-37) were included in the study, and underwent vaginal swab for T. vaginalis detection by means of a quantitative real-time PCR assay, wet mount and an immunochromatographic test. Upon comparing the results, prevalence values observed were 1.3% for real-time PCR, 0.5% for microscopic examination, and 0.8% for the immunochromatographic test. Compared to real-time PCR, wet mount sensitivity was 40% (95% confidence interval 19.1% to 63.9%) and specificity was 100% (95% CI 99.7% to 100%). The sensitivity and specificity of the immunochromatographic assay were 57.9% (95% CI 33.5% to 79.8%) and 99.9% (95% CI 99.6% to 100%), respectively. Evaluation of the wet mount results and those of immunochromatographic assay detection in relation to the number of T. vaginalis DNA copies detected in vaginal samples showed that the lower identification threshold for both wet mount (chi-square 6.1; P = 0.016) and the immunochromatographic assay (chi-square 10.7; P = 0.002) was ≥100 copies of T. vaginalis DNA/5 mcl of eluted DNA.

  16. Hearing threshold evaluation of dentistsin Babol (North of Iran

    Directory of Open Access Journals (Sweden)

    Maryam Ehsani

    2014-03-01

    Full Text Available Introduction:Noise in dental offices is one of the risk factors in the workplace. One of the major effects of noise is hearing loss. This study aimed to determine the effects of noise on hearing thresholds of dentists of Babol city. Methods:This descriptive analytical cross-sectional study was performed on 40 dentists in Babol City (as case group and 40 office workers (as control group. Hearing thresholdswere measured from all the subjects. The mean hearing threshold was calculated at different frequencies in each group and compared with the number 15 db. The data were analyzed by statistical software SPSS17and p≤0.05was considered significant. Results:The mean and standard deviation of hearing thresholds for the right ear of dentists and the control group without considering the different frequencies were 13.6156±9.14210db and10.0156±5.4488db (P=0.036,respectively and for the left ear were12.5115± 8.7609db and 10.059 ± 5.9254db respectively. Hearing threshold of right and left ear of young and middle age dentists was not significant. The hearing thresholds of the dentists with work experience of 15 years or less were not significant for the right and left ear. Auditory thresholds were significant between male and female only for the left ear (P=0.02. Conclusion:There was a change in hearing thresholds at all frequencies. A clear difference was in the left ear of men and women and hearing loss was higher in men. Also, age and working experience were not among the contributing factors to the incidence of noise-induced hearing loss.

  17. Assessment of peritoneal membrane permeability by Tc-99m-excretion in patients undergoing CAPD

    International Nuclear Information System (INIS)

    Das, B.K.; Senthilnathan, M.S.; Pradhan, P.K.; Jeloka, T.K.; Sharma, R.K.

    2002-01-01

    Full text: Among various conservative treatment modalities for end stage renal disease (ESRD), continuous ambulatory peritoneal dialysis (CAPD) is increasingly being used in many centers. The success of CAPD depends largely on the permeable characteristics of the peritoneal membrane. Peritoneal Equilibration Test (PET), first described by Twardowski in 1987, is the most commonly used method for determination of peritoneal membrane characteristics. However, this test has several limitations. In order to find an alternative method for assessing peritoneal membrane characteristics we undertook this prospective study involving 20 patients. The main objective was to determine whether peritoneal excretion of intravenously applied Tc-99m-DTPA can be used for this purpose. 20 patients undergoing regular CAPD were included in this study. 370 MBq (10 mCi) of Tc-99m-DTPA was injected intravenously in the same standard preconditions as for the PET evaluation. A standard dose of 370 MBq (10 mCi) DTPA was kept and used later for calculations. At the end of 4 hours, a dialysate fluid sample was collected and the total dialysis effluent volume was measured. Excretion of Tc-99m-DTPA into the dialysate fluid as percentage of injected dose was calculated. Simultaneously standard PET values were determined. The peritoneal excretion of Tc-99m-DTPA ranged from 8 to 16 % of the injected dose depending upon the peritoneal membrane permeability. The patients were divided into following four groups depending upon DTPA excretion. High transporters (15 % and above); high average(12-15 %); low average (10-12 %); low transporters (10 % and less). When the results were compared with standard PET values, a good correlation could be established. We conclude that the radioisotope method using Tc-99m-DTPA can a good alternative technique to assess peritoneal membrane permeability. (author)

  18. Radiochemical purity and in vitro stability of Tc-99m radiopharmaceuticals

    International Nuclear Information System (INIS)

    Vucina, J.

    2001-01-01

    The increased contents of long lived 99 Tc, oxygen and cupric ions could affect the labeling yield of eight radiopharmaceuticals. Oxygen and in leaser extend copper were found to affect the radiochemical purity of the preparations. In vitro stability of radiopharmaceuticals, examined on 99m Tc(Sn)-pyrosphoshate solutions, was extended when ascorbic acid was added as the chemical stabilizer. The quantity of 5x10 -7 mol/dm 3 of ascorbic acid was found to be sufficient to keep the content of 99m Tc-pertechnetate below 1 % six hours after labeling even in the cases when 99m Tc was present in high radioactive concentrations (740-814 GBq/dm 3 ). The results led to the development of the kits in which ascorbic or gentisic acid are the standards component in the kit composition (author)

  19. A study on 99mTc-macroaggregated albumin as lung imaging agent

    International Nuclear Information System (INIS)

    Xu Rongzhu; Fan Guangyu; Liu Yinmei; Bai Suzhen

    1990-01-01

    A method for the preparation of macroaggregated albumin (MAA) kits labelled with 99m Tc for lung scanning is described. The tween-80 is used as both dispersing agent and stable agent in order to raise uniformity and concentration of MAA particle size, which is between 10 to 100 μm. More than 80% particles are in the range of 10-60 μm. A millilitre MAA solution contains 5.3 x 10 6 particles. The lyophilized MAA kits are stable within eight months. The unlyophilized MAA kits are stable within 51 days. The radiochemical yield is >95% and the radiochemical purity is determined by paper chromatography. In addition, centrifuge method is used in combination with micro paper chromatography, in order to obtain the percentage of 99m Tc(IV) bound to the MAA, the percentage of unreduced 'free' 99m Tc(VII) and the percentage of reduced-hydrolyzed form of 99n Tc(IV). Blank centrifuge test of the 99m Tc(IV)-Sn colloid shows that about 85% 99m Tc(IV) is found in the supernatant solution. This method is simple and rapid. After eight hours the radiochemical purity of the labelled 99m Tc-MAA sample placed at 16 deg C and 22 deg C remains >95%. The organ distribution of LACA 18-26g mice meets the standard of the same product in the US pharmacopeia. The results of the study with rabbits by scanning with γ-camera indicate that the activity in the lung of the rabbit reaches a high level between 2-3 hours after injection. The toxic test and nonsterile and nonpyrogen test are very satisfactory and meet the standard of the Chinese pharmacopeia

  20. Rapid preparation method for technetium-99m bicisate

    Energy Technology Data Exchange (ETDEWEB)

    Hung, J.C. [Nuclear Medicine, Department of Diagnostic Radiology, Mayo Clinic, Rochester, Minnesota (United States); Chowdhury, S. [Nuclear Medicine, Department of Diagnostic Radiology, Mayo Clinic, Rochester, Minnesota (United States); Redfern, M.G. [Nuclear Medicine, Department of Diagnostic Radiology, Mayo Clinic, Rochester, Minnesota (United States); Mahoney, D.W. [Section of Biostatistics, Department of Health Sciences Research, Mayo Clinic, Rochester, Minnesota (United States)

    1997-06-10

    The method currently recommended for the preparation of technetium-99m bicisate ({sup 99m}Tc-bicisate) requires a lengthy 30-min incubation at room temperature. The purpose of this study was to evaluate an alternative method to shorten the preparation time. {sup 99m}Tc-bicisate was prepared with 3.7 GBq (100 mCi) {sup 99m}Tc according to the manufacturer`s instructions, except for the final incubation step, which was replaced with the microwave heating procedure. A standard thin-layer chromatography (TLC) method (i.e., Baker-Flex silica gel IB-F TLC plate with ethyl acetate as mobile phase) was used for the determination of the radiochemical purity (RCP) of {sup 99m}Tc-bicisate. Our evaluation with different microwave heating processes (300 W with different heating times) demonstrated that as the microwave heating temperature was increased (i.e., 44 -71 C), an increased percentage of samples reached 95% within 5 min post preparation (n=58). The highest RCP value (i.e., 97.4%{+-}0.5%, n=10) could be obtained immediately after an 8-s microwave heating time at 300 W (microwave temperature at 69 C), and an average RCP value of 96.4%{+-}1.3% (n=90) was maintained throughout the 24-h evaluation period. However, the trend seemed to reverse at higher microwave temperatures (i.e., 76 -90 C), which reconfirmed our initial findings that overheating had no benefit for the preparation of {sup 99m}Tc-bicisate. To ensure that temperature was the only determining factor, a hot water incubator set at 69 C was used (n=6). Similar RCP results were achieved. In conclusion, the use of a microwave oven at a low heat cycle provides a rapid and efficient way to prepare {sup 99m}Tc-bicisate. (orig.). With 3 figs., 1 tab.

  1. Preparation and biological profile of 99mTc-lidocaine as a cardioselective imaging agent using 99mTc eluted from 99Mo/99mTc generator based on Al-Mo gel

    International Nuclear Information System (INIS)

    Sakr, T.M.; October University of Modern Sciences and Arts; Ibrahim, A.B.; Rashed, H.M.; Fasih, T.W.

    2017-01-01

    The current study is aimed to prepare 99m Tc-lidocaine as a new myocardial perfusion-imaging agent. The used 99m Tc was obtained from Al- 99 Mo-molybdate(VI) gel matrix. 99m Tc-lidocaine showed higher (15.4 ± 0.11% ID/g) and faster (15 min post injection) cardiac uptake than the recently studied 99m Tc-valsartan and 99m Tc-procainamide. Consequently, 99m Tc-lidocaine will be a valuable myocardial SPECT agent for diagnosis of emergency patients. Besides, the receptor affinity study confirmed the selectivity of 99m Tc-lidocaine for sodium channels in the heart. (author)

  2. Color difference thresholds in dentistry.

    Science.gov (United States)

    Paravina, Rade D; Ghinea, Razvan; Herrera, Luis J; Bona, Alvaro D; Igiel, Christopher; Linninger, Mercedes; Sakai, Maiko; Takahashi, Hidekazu; Tashkandi, Esam; Perez, Maria del Mar

    2015-01-01

    The aim of this prospective multicenter study was to determine 50:50% perceptibility threshold (PT) and 50:50% acceptability threshold (AT) of dental ceramic under simulated clinical settings. The spectral radiance of 63 monochromatic ceramic specimens was determined using a non-contact spectroradiometer. A total of 60 specimen pairs, divided into 3 sets of 20 specimen pairs (medium to light shades, medium to dark shades, and dark shades), were selected for psychophysical experiment. The coordinating center and seven research sites obtained the Institutional Review Board (IRB) approvals prior the beginning of the experiment. Each research site had 25 observers, divided into five groups of five observers: dentists-D, dental students-S, dental auxiliaries-A, dental technicians-T, and lay persons-L. There were 35 observers per group (five observers per group at each site ×7 sites), for a total of 175 observers. Visual color comparisons were performed using a viewing booth. Takagi-Sugeno-Kang (TSK) fuzzy approximation was used for fitting the data points. The 50:50% PT and 50:50% AT were determined in CIELAB and CIEDE2000. The t-test was used to evaluate the statistical significance in thresholds differences. The CIELAB 50:50% PT was ΔEab  = 1.2, whereas 50:50% AT was ΔEab  = 2.7. Corresponding CIEDE2000 (ΔE00 ) values were 0.8 and 1.8, respectively. 50:50% PT by the observer group revealed differences among groups D, A, T, and L as compared with 50:50% PT for all observers. The 50:50% AT for all observers was statistically different than 50:50% AT in groups T and L. A 50:50% perceptibility and ATs were significantly different. The same is true for differences between two color difference formulas ΔE00 /ΔEab . Observer groups and sites showed high level of statistical difference in all thresholds. Visual color difference thresholds can serve as a quality control tool to guide the selection of esthetic dental materials, evaluate clinical performance, and

  3. Preliminary studies of 99mTc labeled fatty acid analogs for myocardial imaging

    International Nuclear Information System (INIS)

    Guo Yuzhi; Kung, H.F.; Mack, R.H.

    1988-01-01

    Radio iodine labelled fatty acid analogs are potential myocardial imaging agents for SPECT. In this paper are reported three new 99m Tc labbeled fatty acid analogs: 9 '9 m Tc-BAT-TDA, 99m Tc-BAT-PDA and 99m Tc-BAT-H x DA. Ligand exchange reaction with 99m Tc stannous glucoheptonate in 50% aqueous ethanol is used for labelling. The yield of reactions is 87%, 70%, 49% respectively. 99m Tc-fatty acid is purified by extraction into chloroform and the purity as determined by reverse phase HPLC is 98%. In order to determine the structure of Tc-BAT-fatty acid, 99 Tc-BAT-PDA is synthesized with 99 Tc ammonium pertechnetate in 50% citric acid buffer (pH=6)/ethanol using stannous chloride as the reducing agent. 99 Tc-BAT-PDA displays the expected Tc=O UV absorption at 420nm and strong peak at 900cm -1 in the FTIR spectrum. Biodistribution studies of three 99m Tc-fatty acid analogs are conducted in rats using 125 I-ω- (p-iodophenyl) -penta-decanoic acid (IPPDA) as internal standard. The initial heart uptake of them is significantly lower than that of 125 I-IPPDA

  4. Comparative study of 99Mo/99mTc generators at base of synthesized gels starting from 99Mo of activation and of fission

    International Nuclear Information System (INIS)

    Lopez M, I.Z.; Monroy G, F.; Rivero G, T.; Rojas N, P.

    2007-01-01

    At the present time the more used and diffused radionuclide in nuclear medicine it is the Technetium 99 metastable ( 99 mTc) it is used for diagnostic and therapy. It is produced starting from molybdenum 99 ( 99 Mo), which is absorbed in chromatographic columns, loaded with alumina that absorb only 0.2% of 99 Mo situation that forces to use high specific activities of 99 Mo that it is obtained starting from the fission of the 235 U. Given these conditions and limitations, new preparation procedures of 99 Mo/ 99m Tc generators, of low or medium specific activity, its have been developed, using gels of zirconium molybdates that incorporates until 30% in weight of 99 Mo in the gel, and also conserve similar characteristics of quality and purity that those obtained by the traditional generator; reducing by this way the cost of production of the 99m Tc, when using 99 Mo of low specific activity, in the preparation of 99 Mo/ 99m Tc generators. The radiochemical characteristics of the elution of 99m Tc, depends strongly on the gel preparation conditions. In particular, the present work has for object to determine the influence of the used type of 99 Mo, fission or activation product, during the gels synthesis, as well as the used air flow for the agitation in the gels preparation and its influence in the quality of the 99 Mo/ 99m Tc generators. When diminishing the agitation air flow the efficiency it increases and in the radionuclide purity of the eluates and when using 99 Mo of fission for the gels production it increases in an important way the elution efficiency, the radiochemical purity and radionuclide of the eluates of 99m Tc. (Author)

  5. Technetium-99 in ''instant'' sup(99m)Tc-pertechnetate

    International Nuclear Information System (INIS)

    Mattsson, S.

    1978-01-01

    The 99 Tc-content in sup(99m)Tc-pertechnetate separated from 99 Mo by distillation or extraction has been studied with a plastic scintillation detector. The identification of the measured activity was achieved by beta-spectrometry, chemical separation and half-life studies. The frequency distribution of the sup(99)Tc/sup(99m)Tc-ratios in the different samples was observed to be log-normal. The most likely activity ratio was 0.4x10 -6 , the maximum value being 5x10 -6 . The specific activity of ''instant'' pertechnetate is approximately a factor of 60 lower than that normally recorded in pertechnetate derived from daily eluted column generators. The low specific activity of ''instant'' pertechnetate is primarily explained by the long time between separation and usage and secondly by the low yield of Tc in the distillation and extraction processes. In several of the ''instant'' pertechnetate solutions the carrier concentration exceeded the reductive capacity of the stannous ions in ''kits'' with small amounts of Sn(II) in usable form. (T.G.)

  6. Potential Ways to Address Shortage Situations of 99Mo/99mTc.

    Science.gov (United States)

    Filzen, Leah M; Ellingson, Lacey R; Paulsen, Andrew M; Hung, Joseph C

    2017-03-01

    99m Tc, the most common radioisotope used in nuclear medicine, is produced in a nuclear reactor from the decay of 99 Mo. There are only a few aging nuclear reactors around the world that produce 99 Mo, and one of the major contributors, the National Research Universal (Canada), ceased production on October 31, 2016. The National Research Universal produced approximately 40% of the world's 99 Mo supply, so with its shut down, shortages of 99 Mo/ 99m Tc are expected. Methods: Nuclear pharmacies and nuclear medicine departments throughout the United States were contacted and asked to provide their strategies for coping with a shortage of 99 Mo/ 99m Tc. Each of these strategies was evaluated on the basis of its effectiveness for conserving 99m Tc while still meeting the needs of the patients. Results: From the responses, the following 6 categories of strategies, in order of importance, were compiled: contractual agreements with commercial nuclear pharmacies, alternative imaging protocols, changes in imaging schedules, software use, generator management, and reduction of ordered doses or elimination of backup doses. Conclusion: The supply chain of 99 Mo/ 99m Tc is quite fragile; therefore, being aware of the most appropriate coping strategies is crucial. It is essential to build a strong collaboration between the nuclear pharmacy and nuclear medicine department during a shortage situation. With both nuclear medicine departments and nuclear pharmacies implementing viable strategies, such as the ones proposed, the amount of 99m Tc available during a shortage situation can be maximized. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  7. Mathematics of quantitative kinetic PCR and the application of standard curves.

    Science.gov (United States)

    Rutledge, R G; Côté, C

    2003-08-15

    Fluorescent monitoring of DNA amplification is the basis of real-time PCR, from which target DNA concentration can be determined from the fractional cycle at which a threshold amount of amplicon DNA is produced. Absolute quantification can be achieved using a standard curve constructed by amplifying known amounts of target DNA. In this study, the mathematics of quantitative PCR are examined in detail, from which several fundamental aspects of the threshold method and the application of standard curves are illustrated. The construction of five replicate standard curves for two pairs of nested primers was used to examine the reproducibility and degree of quantitative variation using SYBER Green I fluorescence. Based upon this analysis the application of a single, well- constructed standard curve could provide an estimated precision of +/-6-21%, depending on the number of cycles required to reach threshold. A simplified method for absolute quantification is also proposed, in which quantitative scale is determined by DNA mass at threshold.

  8. Threshold responses of Amazonian stream fishes to timing and extent of deforestation.

    Science.gov (United States)

    Brejão, Gabriel L; Hoeinghaus, David J; Pérez-Mayorga, María Angélica; Ferraz, Silvio F B; Casatti, Lilian

    2017-12-06

    Deforestation is a primary driver of biodiversity change through habitat loss and fragmentation. Stream biodiversity may not respond to deforestation in a simple linear relationship. Rather, threshold responses to extent and timing of deforestation may occur. Identification of critical deforestation thresholds is needed for effective conservation and management. We tested for threshold responses of fish species and functional groups to degree of watershed and riparian zone deforestation and time since impact in 75 streams in the western Brazilian Amazon. We used remote sensing to assess deforestation from 1984 to 2011. Fish assemblages were sampled with seines and dip nets in a standardized manner. Fish species (n = 84) were classified into 20 functional groups based on ecomorphological traits associated with habitat use, feeding, and locomotion. Threshold responses were quantified using threshold indicator taxa analysis. Negative threshold responses to deforestation were common and consistently occurred at very low levels of deforestation (70% deforestation and >10 years after impact. Findings were similar at the community level for both taxonomic and functional analyses. Because most negative threshold responses occurred at low levels of deforestation and soon after impact, even minimal change is expected to negatively affect biodiversity. Delayed positive threshold responses to extreme deforestation by a few species do not offset the loss of sensitive taxa and likely contribute to biotic homogenization. © 2017 Society for Conservation Biology.

  9. Nanostructured metal oxides: promise opportunity and challenge to develop clinically useful 99Mo/99mTc generators using (n, gamma)99Mo

    International Nuclear Information System (INIS)

    Dash, Ashutosh

    2014-01-01

    The role of 99m Tc diagnostic nuclear medicine needs hardly to be reiterated. Today, it is the most widely used radionuclide for single photon emission computed tomography (SPECT) imaging procedures. The current strategy of availing 99m Tc is ensured from column chromatographic 99 Mo/ 99m Tc generators using a bed of acidic alumina. While the column chromatographic 99 Mo/ 99m Tc generator constitute a successful exemplar of availing 99m Tc, the limited capacity of alumina (2-20 mg Mo per g of alumina) for taking up molybdate ions necessitates the use of 99 Mo of the highest specific activity available, as can be found in fission produced 99 Mo (F 99 Mo). In order to reduce dependence of F 99 Mo, the scope of using low specific activity (n,γ) 99 Mo along with high capacity adsorbent is an interesting prospect. In this context, the scope of using nanomaterials as a viable adsorbent seemed attractive by virtue of their huge surface to volume ratios, altered physical properties, tailored surface chemistry, favorable adsorption characteristics, and enhanced surface reactivity resulting from the nanoscale dimensions. This emerging class of adsorbent represents an innovative paradigm and is expected to play an important role in the development of 99 Mo/ 99m Tc generators adaptable to the existing and foreseeable demands. This talk outlines a critical assessment on the role of nanostructured metal oxides, recent developments, the contemporary status, and key challenges and apertures to the near future. (author)

  10. Quantifying the Arousal Threshold Using Polysomnography in Obstructive Sleep Apnea.

    Science.gov (United States)

    Sands, Scott A; Terrill, Philip I; Edwards, Bradley A; Taranto Montemurro, Luigi; Azarbarzin, Ali; Marques, Melania; de Melo, Camila M; Loring, Stephen H; Butler, James P; White, David P; Wellman, Andrew

    2018-01-01

    Precision medicine for obstructive sleep apnea (OSA) requires noninvasive estimates of each patient's pathophysiological "traits." Here, we provide the first automated technique to quantify the respiratory arousal threshold-defined as the level of ventilatory drive triggering arousal from sleep-using diagnostic polysomnographic signals in patients with OSA. Ventilatory drive preceding clinically scored arousals was estimated from polysomnographic studies by fitting a respiratory control model (Terrill et al.) to the pattern of ventilation during spontaneous respiratory events. Conceptually, the magnitude of the airflow signal immediately after arousal onset reveals information on the underlying ventilatory drive that triggered the arousal. Polysomnographic arousal threshold measures were compared with gold standard values taken from esophageal pressure and intraoesophageal diaphragm electromyography recorded simultaneously (N = 29). Comparisons were also made to arousal threshold measures using continuous positive airway pressure (CPAP) dial-downs (N = 28). The validity of using (linearized) nasal pressure rather than pneumotachograph ventilation was also assessed (N = 11). Polysomnographic arousal threshold values were correlated with those measured using esophageal pressure and diaphragm EMG (R = 0.79, p < .0001; R = 0.73, p = .0001), as well as CPAP manipulation (R = 0.73, p < .0001). Arousal threshold estimates were similar using nasal pressure and pneumotachograph ventilation (R = 0.96, p < .0001). The arousal threshold in patients with OSA can be estimated using polysomnographic signals and may enable more personalized therapeutic interventions for patients with a low arousal threshold. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  11. Infrared laser damage thresholds in corneal tissue phantoms using femtosecond laser pulses

    Science.gov (United States)

    Boretsky, Adam R.; Clary, Joseph E.; Noojin, Gary D.; Rockwell, Benjamin A.

    2018-02-01

    Ultrafast lasers have become a fixture in many biomedical, industrial, telecommunications, and defense applications in recent years. These sources are capable of generating extremely high peak power that can cause laser-induced tissue breakdown through the formation of a plasma upon exposure. Despite the increasing prevalence of such lasers, current safety standards (ANSI Z136.1-2014) do not include maximum permissible exposure (MPE) values for the cornea with pulse durations less than one nanosecond. This study was designed to measure damage thresholds in corneal tissue phantoms in the near-infrared and mid-infrared to identify the wavelength dependence of laser damage thresholds from 1200-2500 nm. A high-energy regenerative amplifier and optical parametric amplifier outputting 100 femtosecond pulses with pulse energies up to 2 mJ were used to perform exposures and determine damage thresholds in transparent collagen gel tissue phantoms. Three-dimensional imaging, primarily optical coherence tomography, was used to evaluate tissue phantoms following exposure to determine ablation characteristics at the surface and within the bulk material. The determination of laser damage thresholds in the near-IR and mid-IR for ultrafast lasers will help to guide safety standards and establish the appropriate MPE levels for exposure sensitive ocular tissue such as the cornea. These data will help promote the safe use of ultrafast lasers for a wide range of applications.

  12. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    Science.gov (United States)

    Tagami; Uchida; Hamilton; Robison

    2000-07-01

    Extraction techniques for recovery of technetium-99 (99Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (MI) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g(-1) dry weight (dw). The limit of detection for 99Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g(-1) dw under standard operating conditions.

  13. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    International Nuclear Information System (INIS)

    Tagami, K.; Uchida, S.; Hamilton, T.; Robison, W.

    2000-01-01

    Extraction techniques for recovery of technetium-99 ( 99 Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99 Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99 Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99 Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g -1 dry weight (dw). The limit of detection for 99 Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g -1 dw under standard operating conditions

  14. Decay of 99Mo

    International Nuclear Information System (INIS)

    Dickens, J.K.; Love, T.A.

    1976-01-01

    Relative intensities for K x-rays and gamma rays emanating from 99 Mo in equilibrium with its 99 Tc* daughter have been measured using several Ge photon detectors. Combining these intensities with an evaluated set of electron-conversion coefficients has provided a set of absolute intensities for the observed gamma rays. The absolute intensity for the dominant 140.5-keV gamma ray in 99 Tc was determined to be 90.7 +- 0.6/100 99 Mo disintegrations for 99 Mo decay in equilibrium with decay of the 99 Tc* daughter

  15. In Vitro Evaluation of Tc-99m Radiopharmaceuticals for Gastric Emptying Studies

    Directory of Open Access Journals (Sweden)

    Türkan Ertay

    2014-02-01

    Full Text Available Objective: Gastrointestinal motility and functional motility disorders causing either delayed or accelerated gastric emptying (GE may result in similar symptoms including nausea, vomiting, early satiety, fullness, bloating, and abdominal discomfort or pain. Hence, it is important to evaluate patients for both rapid and delayed GE in the same test. The gold standard technique to measure GE is scintigraphy by radiolabeled test meals. The aim of this study was to test alternative Tc-99m agents to label eggs as the solid meal and compare to Tc-99m sulfur colloid (SC for gastric emptying studies. Methods: In search of alternative agents for gastric emptying studies, we mixed and fried eggs with four different particulate compounds (Tc-99m labeled SC, tin colloid, nanocolloid and MAA, as well as with free pertechnetate and Tc-99m DTPA. We then measured the stability of these compounds in simulated gastric juice. Results: Our experiments demonstrated that in addition to Tc-99m sulfur colloid;Tc-99m MAA, Tc-99m nanocolloid and Tc-99m tin colloid also appear to make stable complexes with eggs in acidic environment. Conclusion: Therefore, these agents may be used for gastric emptying studies which could be more practical in routine conditions.

  16. Music effect on pain threshold evaluated with current perception threshold

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    AIM: Music relieves anxiety and psychotic tension. This effect of music is applied to surgical operation in the hospital and dental office. It is still unclear whether this music effect is only limited to the psychological aspect but not to the physical aspect or whether its music effect is influenced by the mood or emotion of audience. To elucidate these issues, we evaluated the music effect on pain threshold by current perception threshold (CPT) and profile of mood states (POMC) test. METHODS: Healthy 30 subjects (12 men, 18 women, 25-49 years old, mean age 34.9) were tested. (1)After POMC test, all subjects were evaluated pain threshold with CPT by Neurometer (Radionics, USA) under 6 conditions, silence, listening to the slow tempo classic music, nursery music, hard rock music, classic paino music and relaxation music with 30 seconds interval. (2)After Stroop color word test as the stresser, pain threshold was evaluated with CPT under 2 conditions, silence and listening to the slow tempo classic music. RESULTS: Under litening to the music, CPT sores increased, especially 2 000 Hz level related with compression, warm and pain sensation. Type of music, preference of music and stress also affected CPT score. CONCLUSION: The present study demonstrated that the concentration on the music raise the pain threshold and that stress and mood influence the music effect on pain threshold.

  17. Behavior of technetium-99 in soils and plants. Final report, April 1, 1974--December 31, 1978

    International Nuclear Information System (INIS)

    Gast, R.G.; Landa, E.R.; Thorvig, L.J.; Grigal, D.F.; Balogh, J.C.

    1979-01-01

    Studies described in this report were aimed at establishing the magnitude and mechanisms of 99 Tc sorption by soils and uptake by plants. Results show that 99 Tc was sorbed from solution over a period to two to five weeks by 8 of 11 soils studies. The slow rate of sorption, the lack of sorption by low organic matter soils, the elimination of sorption following sterilization and increased sorption following addition of dextrose all point to a microbial role in the sorption process. However, it has not been established whether this is a direct or indirect role nor is it possible to clearly predict the conditions under which sorption will occur. Results of plant uptake studies show that 99 Tc can be taken up and translocated into the photosynthetic tissue of higher plants with concentrations in seeds being much less than in vegetative tissue. Technetium-99 was also shown to be toxic to plants at low concentrations and evidence suggests that this is a chemically rather than radiologically induced toxicity. However, this remains to be completely resolved as well as whether there is a threshold level of 99 Tc required before toxicity occurs. Studies of short-term, dynamic, aerobic systems indicated that 99 Tc moves through the soil as a relatively large anion exhibiting characteristic miscible displacement with some asymmetric tailing. 99 Tc exhibits greater retention that C1 - , which may be attributed statistically to weak complexion by organic matter. It is unlikely that this retention phenomenon is related to the static sorption activity reported in the first part of this study

  18. A new look at 99Tc releases to the atmosphere

    International Nuclear Information System (INIS)

    Till, J.E.; Hoffman, F.O.; Dunning, D.E. Jr.

    1979-01-01

    Recent experimental data suggest that the uptake of 99 Tc by vegetation from soils may be two to three orders of magnitude higher than the 0.25 value currently being used in radiological assessments. Following a survey of the literature, a concentration factor of 50 was applied to evaluate the dose from a 1.0 Ci/yr-release to the atmosphere by a hypothetical uranium enrichment facility. Doses to the GI tract and thyroid of an adult living 1600 m from the facility were 18 mrem and 80 mrem respectively. These doses are delivered entirely through transport of 99 Tc through food chain pathways. This assessment indicates a potential for 99 Tc exposures to exceed recently proposed standards of the U.S. Environmental Protection Agency in 40 CFR 190. The previously assumed concentration factor of 0.25 would have produced corresponding doses of 0.13 mrem to the GI tract and 0.57 mrem to the thyroid. The results of this analysis demonstrate the need for additional research on the environmental behaviour and dosimetry of 99 Tc. In particular, data are needed to elucidate the retention of 99 Tc in soils and the uptake of 99 Tc by edible vegetation in field studies simulating chronic exposure conditions. Data on the uptake and retention of 99 Tc in humans are also necessary to improve the reliability of dose conversion factors for specific organs and various age groups. (author)

  19. Detecting fatigue thresholds from electromyographic signals: A systematic review on approaches and methodologies.

    Science.gov (United States)

    Ertl, Peter; Kruse, Annika; Tilp, Markus

    2016-10-01

    The aim of the current paper was to systematically review the relevant existing electromyographic threshold concepts within the literature. The electronic databases MEDLINE and SCOPUS were screened for papers published between January 1980 and April 2015 including the keywords: neuromuscular fatigue threshold, anaerobic threshold, electromyographic threshold, muscular fatigue, aerobic-anaerobictransition, ventilatory threshold, exercise testing, and cycle-ergometer. 32 articles were assessed with regard to their electromyographic methodologies, description of results, statistical analysis and test protocols. Only one article was of very good quality. 21 were of good quality and two articles were of very low quality. The review process revealed that: (i) there is consistent evidence of one or two non-linear increases of EMG that might reflect the additional recruitment of motor units (MU) or different fiber types during fatiguing cycle ergometer exercise, (ii) most studies reported no statistically significant difference between electromyographic and metabolic thresholds, (iii) one minute protocols with increments between 10 and 25W appear most appropriate to detect muscular threshold, (iv) threshold detection from the vastus medialis, vastus lateralis, and rectus femoris is recommended, and (v) there is a great variety in study protocols, measurement techniques, and data processing. Therefore, we recommend further research and standardization in the detection of EMGTs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Comparative study of {sup 99}Mo/{sup 99m}Tc generators at base of synthesized gels starting from activation and fission {sup 99}Mo; Estudio comparativo de generadores {sup 99}Mo/{sup 99m}Tc a base de geles sintetizados a partir de {sup 99}Mo de activacion y de fision

    Energy Technology Data Exchange (ETDEWEB)

    Lopez M, I Z [UAEM, Paseo Colon esq. Paseo Tollocan, 50120 Toluca, Estado de Mexico (Mexico); Monroy G, F; Rivero G, T; Rojas N, P [ININ, Carretera Mexico -Toluca S/N, 52045 La Marquesa Ocoyoacac, Estado de Mexico (Mexico)

    2007-07-01

    The {sup 99m}Tc is used for diagnostic and therapy. It is produced starting from {sup 99}Mo, absorbed in chromatographic columns, loaded with alumina that absorb only 0.2% of {sup 99}Mo with high specific activities of {sup 99}Mo, obtained from the {sup 235}U fission. Given these conditions and limitations, new preparation procedures of {sup 99}Mo/{sup 99m}Tc generators, its have been developed, using zirconium molybdates gels that incorporates until 30% of {sup 99}Mo, conserve similar characteristics of quality and purity that the traditional generator. The radiochemical characteristics of the {sup 99m}Tc elution, depend strongly on the gel preparation conditions. In particular, the present work has by object to determine the influence of the {sup 99}Mo used type, fission or activation product, during the gels synthesis, as well as the used air flow for the agitation in the gels preparation and its influence in the {sup 99}Mo/{sup 99m}Tc generators quality. When diminishing the flow of agitation air the efficiency it increases and in the radionuclide purity of the eluates and when using {sup 99}Mo from fission for the gels production it increases in an important way the elutriation efficiency, the radiochemical and radionuclide purity of the {sup 99m}Tc eluates. (Author)

  1. Results of regular study on radionuclidic purity of sup(99m)Tc obtained from 99Mo-sup(99m)Tc generators

    International Nuclear Information System (INIS)

    Vlcek, J.; Rohacek, J.; Husak, V.

    1979-01-01

    A total of 39 sup(99m)Tc eluates obtained from 9 99 Mo-sup(99m)Tc generators delivered by The Radiochemical Centre Amersham during one year was studied with regard to their radionuclide purity. Using a Ge(Li) spectrometer the contaminants 60 Co, 103 Ru, 131 I, 134 Cs, 140 La and 188 Re were found in sup(99m)Tc-eluates with average levels ranging from 2.9 x 10 -3 to 2.8 x 10 -1 per cent of sup(99m)Tc activity. The additional total body absorbed dose caused by these contaminants, as calculated from their average content in sup(99m)Tc eluates, was less than 1% of the dose due to sup(99m)Tc pertechnetate. (orig.) 891 MG/orig. 892 CS [de

  2. Inactive Tanks Remediation Program Batch I, Series I tanks 3001-B, 3004-B, 3013, and T-30 technical memorandum. Environmental Restoration Program

    International Nuclear Information System (INIS)

    1995-05-01

    This technical memorandum provides information that can be used to make decisions concerning the disposition of four inactive tank systems that have been designated Batch 1, Series 1, by the Inactive Tanks Remediation Program team. The Batch I, Series 1, tanks are 3001-B, 3004-B, 3013, and T-30. The report offers viable alternatives for tank system disposition. The Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) requires a Federal Facility Agreement (FFA) for federal facilities placed on the National Priorities List. The Oak Ridge Reservation was placed on that list on December 21, 1989, and the agreement was signed in November 1991 by DOE's Oak Ridge Operations Office, the US Environmental Protection Agency-Region IV, and the Tennessee Department of Environment and Conservation. The effective date of the FFA is January 1, 1992. One objective of the FFA is to ensure that inactive liquid low-level radioactive waste tank systems are evaluated and, if appropriate, remediated through the CERCLA process. The Inactive Tanks Remediation Program and the Gunite and Associated Tanks Project (GAAT) are the two efforts that will meet this FFA objective. This memorandum addresses tank systems within the Inactive Tanks Remediation Program. Separate CERCLA documentation addresses the tank systems within the GAAT Project

  3. THE CLINICAL SIGNIFICANCE OF 99mTc-MIBI BREAST IMAGING IN THE DIAGNOSIS OF EARLY BREAST CANCER

    Institute of Scientific and Technical Information of China (English)

    任长才; 金少津; 邹强; 朱汇庆; 王红鹰; 梁春立

    2001-01-01

    Objective: To find an effective, sensitive, specific and noninvasive diagnostic method of breast cancer. Methods: 109 masses of 102 patients with breast lesions smaller than 2 cm in diameter were divided into three groups to undergo 99mTc-MIBI imaging and compared with the results of pathology examination. 20 cases without breast lesions were selected as control. Abnormal condensation of 99mTc-MIBI in the breast reaching 10% higher than that in the counterpart of the healthy breast was regarded as positive. Results: Of 32 breast cancers, positive imaging appeared in 25. Negative imaging were found in 31 of 38 benign breast lesions. Of 39 occult breast lesions, positive imaging appeared in 6 and 3 of them were breast cancer, 2 of 3 patients with slightly increased 99mTc-MIBI imaging threshold were breast cancer also. No positive imaging was found in the control group. The diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value of 99mTc-MIBI was 88.4%, 89.2%, 88.0%, 75.0% and 95.3%, respectively. Conclusion: 99mTc-MIBI imaging had higher sensitivity and accuracy in the diagnosis of breast cancer and differentiation between benign and malignant breast lesions. It could provide useful information for the diagnosis of clinically suspected breast cancer.

  4. Radionuclidic contamination of 99Mo, 131I and 103Ru in the eluate of 99Mo-99mTc chromatographic generator: comparision on fission produced 99Mo from RPC, Nordio and ARI

    International Nuclear Information System (INIS)

    Soenarjo, Sunarhadijoso; Gunawan, Adang Hardi

    1996-01-01

    The 99 Mo- 99m Tc Chromatographic generators is the most popular system to provide 99m Tc medical radioisotope. Radioisotope Production Centre (RPC)- BATAN has routinely produced the generator loaded with 99 Mo prepared by 235 U fission. By using fission produced 99 Mo, the resulting 99m Tc is potentially contaminated by other fission products which are difficult to eliminate completely. In order to study the characteristic of the generator and radionuclidic impurity pattern of the 99m Tc eluates, an evaluation of gamma spectrometric determination has been carried out. The bulk solutions of 99 Mo produced by RPC BATAN (Indonesia), Nordion (Canada) and ARI (Australia) were loaded to generators manufactured between July 1993 to May 1994. The saline-eluate 99m Tc, in a total volume of 10 ml each, was subjected to gamma spectrometric determination. The radiation of 99m Tc was eliminated by lead shield of 0.6913 cm thickness. The 99m Tc yield fluctuation from 28 generators indicated that the characteristics of the generator columns were very good. The 99m Tc eluates were consistently contaminated by 99 Mo, 131 I and 103 Ru, although the contamination level in all cases did not exceed the maximum permissible levels. The fluctuation of radionuclidic impurities were probably caused by variation in the irradiation parameter or by variation in the 99 Mo separation methods. (author), 23 refs, 1 tab, 3 figs

  5. Heat-related deaths in hot cities: estimates of human tolerance to high temperature thresholds.

    Science.gov (United States)

    Harlan, Sharon L; Chowell, Gerardo; Yang, Shuo; Petitti, Diana B; Morales Butler, Emmanuel J; Ruddell, Benjamin L; Ruddell, Darren M

    2014-03-20

    In this study we characterized the relationship between temperature and mortality in central Arizona desert cities that have an extremely hot climate. Relationships between daily maximum apparent temperature (ATmax) and mortality for eight condition-specific causes and all-cause deaths were modeled for all residents and separately for males and females ages heat. For this condition-specific cause of death, the heat thresholds in all gender and age groups (ATmax = 90-97 °F; 32.2-36.1 °C) were below local median seasonal temperatures in the study period (ATmax = 99.5 °F; 37.5 °C). Heat threshold was defined as ATmax at which the mortality ratio begins an exponential upward trend. Thresholds were identified in younger and older females for cardiac disease/stroke mortality (ATmax = 106 and 108 °F; 41.1 and 42.2 °C) with a one-day lag. Thresholds were also identified for mortality from respiratory diseases in older people (ATmax = 109 °F; 42.8 °C) and for all-cause mortality in females (ATmax = 107 °F; 41.7 °C) and males Heat-related mortality in a region that has already made some adaptations to predictable periods of extremely high temperatures suggests that more extensive and targeted heat-adaptation plans for climate change are needed in cities worldwide.

  6. '99Mo/99mTc Generator Based on High Radionuclidic Pure Zirconium Molybdate Gel

    International Nuclear Information System (INIS)

    Amin, M.; Mostafa, M.; El-Amir, M.A.; El-Absy, M.A.; Mohamed, O.I.; Farag, A.B.

    2014-01-01

    99 Mo / 99 mTc radioisotope generator was prepared using in-situ precipitated zirconium molybdate chromatographic column. Zirconium molybdate gel matrix was synthesized by precipitation of neutron activation molybdenum-99 from its solution after variety purification processes to prevent contamination of the 99m Tc eluate with cross-contaminants. Greeter than 82.7 ± 0.4 % of the generated 99m Tc was immediately and reproducible eluted by passing 10 ml 0.9 % NaCl solution through the 1 g zirconium molybdate- 99 Mo column matrix at a flow rate of 0.5 ml / min and room temperature with high chemical, radionuclide ( ≥ 99.9 % 99m Tc) and radiochemical purity ( ≥ 97.7 % % as 99 mTcO 4 - ) with ph value suitable for medical uses.

  7. Magnesium-Molybate Compounds as Matrix for 99Mo/99mTc Generators

    Directory of Open Access Journals (Sweden)

    Fabiola Monroy-Guzman

    2011-01-01

    Full Text Available This work reports the preparation of a 99mTc generator based on conversion of 99Mo produced by neutron irradiation, into insoluble magnesium 99Mo-molybdates compounds as matrix. The effect of magnesium salt types and concentration, Mg:Mo molar ratios, pH of molybdate solutions, eluate volume as well as the addition order of molybdate and magnesium solutions’ influences on the final 99mTc were evaluated. Polymetalates and polymolybdates salts either crystallized or amorphous were obtained depending on the magnesium salt and Mg:Mo molar ratio used in matrix preparation. 99Mo/99mTc generator production based on magnesium-99Mo molybdate compounds allow reduction of preparation time and eliminates the use of specialized installations. The best generator performances were attained using matrices prepared from 0.1 mol/L MgCl2·6H2O solutions, ammonium molybdate solutions at pH 7 and at a Mg:Mo molar ratio of 1:1.

  8. Radionuclide Basics: Technetium-99

    Science.gov (United States)

    Technetium-99 (chemical symbol Tc-99) is a silver-gray, radioactive metal. It occurs naturally in very small amounts in the earth's crust, but is primarily man-made. Technetium-99m is a short-lived form of Tc-99 that is used as a medical diagnostic tool.

  9. 99Mo-99mTc generator - study of their performance and quality

    International Nuclear Information System (INIS)

    Acar, M.E.D.

    1987-01-01

    In this work the performance of the 99 Mo - 99m Tc generators produced at IPEN-CNEN/SP as well as the quality of the eluted solutions were analysed. The following parameters were studied: elution efficiency, chemical radiochemical, radionuclidic and microbiological purities and pH of the eluates. The 99m Tc yield ranged from 84,7 to 98,5%. The radioactivity due to the pertechnetate ion in the studied solutions was higher than 97,5%. The aluminium content in eluates, determined by spectrophotometry, was lower than 2,5 μg/ml and the pH of the solutions between 4,5 and 5,1. Radioactive impurities of the order of 10 -3 KBq 99 Mc/MBq 99m Tc and 10 -5 KBq 131 I/MBq 99m Tc were found in the eluates at the time of elution. Other γ emitting radioactive impurities were order of 10 -3 KBq/MBq 99m Tc. The eluates were sterile and pyrogen-free. From the results obtained in this work one can state that the IPEN-TEC generator is a reliable source of good quality 99m Tc-pertechnetate. (author) [pt

  10. Speech-in-Noise Tests and Supra-threshold Auditory Evoked Potentials as Metrics for Noise Damage and Clinical Trial Outcome Measures.

    Science.gov (United States)

    Le Prell, Colleen G; Brungart, Douglas S

    2016-09-01

    In humans, the accepted clinical standards for detecting hearing loss are the behavioral audiogram, based on the absolute detection threshold of pure-tones, and the threshold auditory brainstem response (ABR). The audiogram and the threshold ABR are reliable and sensitive measures of hearing thresholds in human listeners. However, recent results from noise-exposed animals demonstrate that noise exposure can cause substantial neurodegeneration in the peripheral auditory system without degrading pure-tone audiometric thresholds. It has been suggested that clinical measures of auditory performance conducted with stimuli presented above the detection threshold may be more sensitive than the behavioral audiogram in detecting early-stage noise-induced hearing loss in listeners with audiometric thresholds within normal limits. Supra-threshold speech-in-noise testing and supra-threshold ABR responses are reviewed here, given that they may be useful supplements to the behavioral audiogram for assessment of possible neurodegeneration in noise-exposed listeners. Supra-threshold tests may be useful for assessing the effects of noise on the human inner ear, and the effectiveness of interventions designed to prevent noise trauma. The current state of the science does not necessarily allow us to define a single set of best practice protocols. Nonetheless, we encourage investigators to incorporate these metrics into test batteries when feasible, with an effort to standardize procedures to the greatest extent possible as new reports emerge.

  11. 99Mo production by 100Mo(n,2n)99Mo using accelerator neutrons

    International Nuclear Information System (INIS)

    Sato, Nozomi; Kawabata, Masako; Nagai, Yasuki; Hashimoto, Kazuyuki; Hatsukawa, Yuichi; Saeki, Hideya; Motoishi, Shoji; Kin, Tadahiro; Konno, Chikara; Ochiai, Kentaro; Takakura, Kosuke; Minato, Futoshi; Iwamoto, Osamu; Iwamoto, Nobuyuki; Hashimoto, Shintaro

    2013-01-01

    We proposed a new route to produce a medical radioisotope 99 Mo by the 100 Mo(n,2n) 99 Mo reaction using accelerator neutrons. A high-quality 99 Mo with a minimum level of radioactive waste can be obtained by the proposed reaction. The decay product of 99 Mo, 99m Tc, is separated from 99 Mo by the sublimation method. The proposed route could bring a major breakthrough in the solution of ensuring a constant and reliable supply of 99 Mo. (author)

  12. Present status of Mo-99/Tc-99m generator in Thailand

    International Nuclear Information System (INIS)

    Khongpetch, Pranom

    2007-01-01

    Isotop Production Program, Office of Atoms for Peace had produced technetium-99m by MEK extraction of Mo-99 obtained from (n,γ) reaction in TRIGA Mark III reactor and supplied to nuclear medicine centers in Bangkok from 1980 to 1997. Because of the difficulty to meet the increased demand and limitation of reactor operation, the production of technetium-99m was stopped in 1997. Presently, there are 21 nuclear medicine centers with 25 SPECT, 7 gamma camera and 3 PET. All nuclear medicine centers are currently using imported Tc-99m generator. (author)

  13. Quality control studies of 99Mo used in 99Mo/99mTc generators produced at IPEN/CNEN-SP, Brazil

    International Nuclear Information System (INIS)

    Said, Daphne S.; Brambilla, Tania P.; Matsuda, Margareth M.N.; Osso Junior, Joao A.

    2015-01-01

    99m Tc is the most used radionuclide in nuclear medicine. In Brazil, the 99 Mo/ 99m Tc generators are produced exclusively by the Center of Radiopharmacy at IPEN-CNEN/SP, by importing 99 Mo from different suppliers. 99 Mo (t 1/2 = 66 h) is a fission product of 235 U, therefore, it can be accompanied by several radioisotopes that are highly prejudicial for human health, demanding a strict quality control of this product for generators safe use. The European Pharmacopoeia established some parameters and limits that evaluate the quality of the solution of sodium [ 99 Mo]molybdate, that is used as raw material for generator's production. The European Pharmacopoeia also recommends some analytical methods to perform these evaluations, however, it has been observed difficulties on the implementation of these methods by the generator's producers. These difficulties are probably related to the lack of practicability of the proposed methods and the extensive list of utilized reagents. In this work some procedures of the European Pharmacopoeia's quality control method for 99 Mo were evaluated. Different types of solid phase exchanger cartridges were tested for retention of 99 Mo in 3 different conditions. Cartridges that presented percentages of retention higher than 90% were also tested for separation of 99 Mo from possible contaminants (Ru e Te). The results shown that solid phase exchanger cartridges that presented percentages of retention of Mo higher than 90% also presented significant percentages of retention of Ru and Te. An alternative method for separation of 99 Mo from 131 I (other contaminant) are also proposed. (author)

  14. Particle identification using the time-over-threshold method in the ATLAS Transition Radiation Tracker

    International Nuclear Information System (INIS)

    Akesson, T.; Arik, E.; Assamagan, K.; Baker, K.; Barberio, E.; Barberis, D.; Bertelsen, H.; Bytchkov, V.; Callahan, J.; Catinaccio, A.; Danielsson, H.; Dittus, F.; Dolgoshein, B.; Dressnandt, N.; Ebenstein, W.L.; Eerola, P.; Farthouat, P.; Froidevaux, D.; Grichkevitch, Y.; Hajduk, Z.; Hansen, J.R.; Keener, P.T.; Kekelidze, G.; Konovalov, S.; Kowalski, T.; Kramarenko, V.A.; Krivchitch, A.; Laritchev, A.; Lichard, P.; Lucotte, A.; Lundberg, B.; Luehring, F.; Mailov, A.; Manara, A.; McFarlane, K.; Mitsou, V.A.; Morozov, S.; Muraviev, S.; Nadtochy, A.; Newcomer, F.M.; Olszowska, J.; Ogren, H.; Oh, S.H.; Peshekhonov, V.; Rembser, C.; Romaniouk, A.; Rousseau, D.; Rust, D.R.; Schegelsky, V.; Sapinski, M.; Shmeleva, A.; Smirnov, S.; Smirnova, L.N.; Sosnovtsev, V.; Soutchkov, S.; Spiridenkov, E.; Tikhomirov, V.; Van Berg, R.; Vassilakopoulos, V.; Wang, C.; Williams, H.H.

    2001-01-01

    Test-beam studies of the ATLAS Transition Radiation Tracker (TRT) straw tube performance in terms of electron-pion separation using a time-over-threshold method are described. The test-beam data are compared with Monte Carlo simulations of charged particles passing through the straw tubes of the TRT. For energies below 10 GeV, the time-over-threshold method combined with the standard transition-radiation cluster-counting technique significantly improves the electron-pion separation in the TRT. The use of the time-over-threshold information also provides some kaon-pion separation, thereby significantly enhancing the B-physics capabilities of the ATLAS detector

  15. 3. Congress of the SA Society of nuclear medicine: Technetium-99m technology

    International Nuclear Information System (INIS)

    Beyers, M.

    1988-08-01

    The Atomic Energy Corporation of SA Limited have been engaged in the manufacture of radioisotopes since 1967, shortly after the SAFARI-1 reactor at Pelindaba was commissioned. Since then the use of radioisotopes in South Africa has grown rapidly and at present 95% of the in vivo diagnostic radioisotopes (radiopharmaceuticals) utilized in nuclear medicine are manufactured locally. Because radioisotopes are applied mainly in sophisticated chemically or mechanically processed forms, production requires not only a skilled production team, but also the appropriate facilities for the manufacture of high-quality products which comply with the necessary safety standards. Compliance with such standards is especially important for the routine production of radiopharmaceuticals for use in nuclear medicine. Over the past 20 years technetium-99m has achieved a dominant position among the diagnostic tools in modern nuclear medicine.The scope of nuclear medicine is expanding continuously and its future lies primarily in the development of new organspecific technetium-99m radiodiagnostic agents. Many improvements and changes have been made to Tc-99m generators, the major source of Tc-99m, since they were introduced to nuclear medicine in the late 1950's. The new Peltek-F sterile Tc-99m generator developed by the Isotope Production Centre is a symbol of progress made. In order to commemorate the launching of the new Peltek-F technetium-99m generator during August 1988 it was decided to publish six papers that were presented at the Third Congress of the Society of Nuclear Medicine held at Bloemfontein during the period 15 - 17 August 1988 by members of the Isotope Production Centre. This will serve as a useful reference on various aspects of technetium-99m technology and will stimulate the use of this product as well as new research in this field

  16. Evaluation of renal function using 99mTc-MAG3

    International Nuclear Information System (INIS)

    Takayama, Teruhiko; Aburano, Tamio; Shuke, Noriyuki

    1993-01-01

    The utility of 99m Tc-mercaptoacetyltriglycine (MAG3) was studied clinically. In the renography obtained with 99m Tc-MAG3, the abdominal aorta and the common iliac arteries were clearly visualized in the vascular phase. Due to less background activity and high target to background ratio, the quality of 99m Tc-MAG3 image was superior to that of 123 I-OIH or 99m Tc-DTPA image. The parameters on the renogram including T max , T 2/3 , and T 1/2 were compared. The correlation of T max and T 2/3 or T 1/2 were not significant between 99m Tc-MAG3 and 123 I-OIH. Another parameter of C 20 /C max , where C 20 and C max are renal activities at 20 min after injection and at T max respectively, showed an excellent correlation between 99m Tc-MAG3 and 123 I-OIH. Using C 20 /C max , pattern of renogram can be characterized numerically. Concerning the relation between C 20 /C max and renogram pattern, standard renogram pattern showed the C 20 /C max value of less than 0.4, while hypofunctioning pattern showed more than 0.5. The correlation coefficient between the renal uptake of 99m Tc-MAG3 and 123 I-OIH was 0.880 with a correlation plot: 'Y=1.16X-0.043', where X and Y represent renal uptake of 99m Tc-MAG3 and 123 I-OIH, respectively. It can be concluded that 99m Tc-MAG3 is a useful renal imaging agent as an alternative to 123 I-OIH, in order to evaluate the proximal tubular function and calculate ERPF. (author)

  17. Production of Molybdenum-99 using Neutron Capture Methods

    Energy Technology Data Exchange (ETDEWEB)

    Toth, James J; Greenwood, Lawrence R; Soderquist, Chuck Z; Wittman, Richard S; Pierson, Bruce D; Burns, Kimberly A; Lavender, Curt A; Painter, Chad L; Love, Edward F; Wall, Donald E

    2011-01-01

    the system has exactly the same chemical and radiochemical characteristics as the Tc-99m currently produced by standard generator systems. Analysis results indicate: • The production of Mo99 is a function of the neutron flux in the thermal and epithermal region, the target volume, and the target geometry. Calculations show that neutron self-absorption is not very important such that large (2 cm OD or more) cylinders of molybdenum can be irradiated without significant losses. • Efficient use of target volume design is function of simultaneously optimizing the amount of molybdenum that can be inserted into each irradiation capsule and the amount of interconnected porosity within the specimen body to enhance the rate of post-irradiation dissolution. • Neutron capture of natural molybdenum may effectively achieve up to 1 Ci/g Mo99 in a 144 hour irradiation period, when using the fuel annulus plus a beryllium reflector configuration.

  18. Clinical Practice Guidelines From the AABB: Red Blood Cell Transfusion Thresholds and Storage.

    Science.gov (United States)

    Carson, Jeffrey L; Guyatt, Gordon; Heddle, Nancy M; Grossman, Brenda J; Cohn, Claudia S; Fung, Mark K; Gernsheimer, Terry; Holcomb, John B; Kaplan, Lewis J; Katz, Louis M; Peterson, Nikki; Ramsey, Glenn; Rao, Sunil V; Roback, John D; Shander, Aryeh; Tobian, Aaron A R

    2016-11-15

    More than 100 million units of blood are collected worldwide each year, yet the indication for red blood cell (RBC) transfusion and the optimal length of RBC storage prior to transfusion are uncertain. To provide recommendations for the target hemoglobin level for RBC transfusion among hospitalized adult patients who are hemodynamically stable and the length of time RBCs should be stored prior to transfusion. Reference librarians conducted a literature search for randomized clinical trials (RCTs) evaluating hemoglobin thresholds for RBC transfusion (1950-May 2016) and RBC storage duration (1948-May 2016) without language restrictions. The results were summarized using the Grading of Recommendations Assessment, Development and Evaluation method. For RBC transfusion thresholds, 31 RCTs included 12 587 participants and compared restrictive thresholds (transfusion not indicated until the hemoglobin level is 7-8 g/dL) with liberal thresholds (transfusion not indicated until the hemoglobin level is 9-10 g/dL). The summary estimates across trials demonstrated that restrictive RBC transfusion thresholds were not associated with higher rates of adverse clinical outcomes, including 30-day mortality, myocardial infarction, cerebrovascular accident, rebleeding, pneumonia, or thromboembolism. For RBC storage duration, 13 RCTs included 5515 participants randomly allocated to receive fresher blood or standard-issue blood. These RCTs demonstrated that fresher blood did not improve clinical outcomes. It is good practice to consider the hemoglobin level, the overall clinical context, patient preferences, and alternative therapies when making transfusion decisions regarding an individual patient. Recommendation 1: a restrictive RBC transfusion threshold in which the transfusion is not indicated until the hemoglobin level is 7 g/dL is recommended for hospitalized adult patients who are hemodynamically stable, including critically ill patients, rather than when the hemoglobin level

  19. 49 CFR 1242.33 - Other expenses and casualties and insurance (accounts XX-17-99, XX-18-99, XX-19-99, 50-17-00, 50...

    Science.gov (United States)

    2010-10-01

    ... (accounts XX-17-99, XX-18-99, XX-19-99, 50-17-00, 50-18-00, and 50-19-00). 1242.33 Section 1242.33....33 Other expenses and casualties and insurance (accounts XX-17-99, XX-18-99, XX-19-99, 50-17-00, 50... separation of administrative—other (account XX-19-06). Operating Expenses—Equipment locomotives ...

  20. Alternative chromatographic system for the quality control of lipophilic technetium-99m radiopharmaceuticals such as [{sup 99m}Tc(MIBI){sub 6}]{sup +}

    Energy Technology Data Exchange (ETDEWEB)

    Faria, D.P.; Buchpiguel, C.A.; Marques, F.L.N., E-mail: danielefaria1@gmail.com [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Departamento de Radiologia. Servico de Medicina Nuclear

    2015-10-15

    Knowledge of the radiochemical purity of radiopharmaceuticals is mandatory and can be evaluated by several methods and techniques. Planar chromatography is the technique normally employed in nuclear medicine since it is simple, rapid and usually of low cost. There is no standard system for the chromatographic technique, but price, separation efficiency and short time for execution must be considered. We have studied an alternative system using common chromatographic stationary phase and alcohol or alcohol:chloroform mixtures as the mobile phase, using the lipophilic radiopharmaceutical [{sup 99m}Tc(MIBI){sub 6}]{sup +} as a model. Whatman 1 modified phase paper and absolute ethanol, Whatman 1 paper and methanol: chloroform (25:75), Whatman 3MM paper and ethanol:chloroform (25:75), and the more expensive ITLC-SG and 1-propanol: chloroform (10:90) were suitable systems for the direct determination of radiochemical purity of [{sup 99m}Tc(MIBI){sub 6}]{sup +} since impurities such as {sup 99m}Tc-reduced-hydrolyzed (RH), {sup 99m}TcO4{sup -} and [{sup 99m}Tc(cysteine){sub 2}]{sup -} complex were completely separated from the radiopharmaceutical, which moved toward the front of chromatographic systems while impurities were retained at the origin. The time required for analysis was 4 to 15 min, which is appropriate for nuclear medicine routines. (author)

  1. Evaluation of renal function using [sup 99m]Tc-MAG3; Comparison with [sup 123]I-OIH and [sup 99m]Tc-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Takayama, Teruhiko; Aburano, Tamio; Shuke, Noriyuki (Kanazawa Univ. (Japan). School of Medicine) (and others)

    1993-07-01

    The utility of [sup 99m]Tc-mercaptoacetyltriglycine (MAG3) was studied clinically. In the renography obtained with [sup 99m]Tc-MAG3, the abdominal aorta and the common iliac arteries were clearly visualized in the vascular phase. Due to less background activity and high target to background ratio, the quality of [sup 99m]Tc-MAG3 image was superior to that of [sup 123]I-OIH or [sup 99m]Tc-DTPA image. The parameters on the renogram including T[sub max], T[sub 2/3], and T[sub 1/2] were compared. The correlation of T[sub max] and T[sub 2/3] or T[sub 1/2] were not significant between [sup 99m]Tc-MAG3 and [sup 123]I-OIH. Another parameter of C[sub 20]/C[sub max], where C[sub 20] and C[sub max] are renal activities at 20 min after injection and at T[sub max] respectively, showed an excellent correlation between [sup 99m]Tc-MAG3 and [sup 123]I-OIH. Using C[sub 20]/C[sub max], pattern of renogram can be characterized numerically. Concerning the relation between C[sub 20]/C[sub max] and renogram pattern, standard renogram pattern showed the C[sub 20]/C[sub max] value of less than 0.4, while hypofunctioning pattern showed more than 0.5. The correlation coefficient between the renal uptake of [sup 99m]Tc-MAG3 and [sup 123]I-OIH was 0.880 with a correlation plot: 'Y=1.16X-0.043', where X and Y represent renal uptake of [sup 99m]Tc-MAG3 and [sup 123]I-OIH, respectively. It can be concluded that [sup 99m]Tc-MAG3 is a useful renal imaging agent as an alternative to [sup 123]I-OIH, in order to evaluate the proximal tubular function and calculate ERPF. (author).

  2. Evaluation of technetium-99m-Mag3-clearance. A pilot study of industry for the standardization of software

    International Nuclear Information System (INIS)

    Stritzke, H.P.

    1996-01-01

    The manufacturers for gamma camera systems and their distribution organisations in Germany, ADAC, Elscint, Gaede, General Electric, Picker, Siemens, Sopha and Toshiba initiated in cooperation with the Central Association of the Electro and Electronic Industry (Zentralverband der Elektro-und Elektronikindustrie eV, ZVEl), a pilot study to test whether the clinical computer programs for the calculation of the Technetium-99m-Mag 3 Clearance according Bubeck deliver comparable results. For this purpose three dynamic scintigraphic renal studies were converted to interfile format and were sent to the firms at two occasions including blood sampling data and anonymousized patient information. The results were returned to the SAM GmbH System Analysen in der Medizin (Bad Oeynhausen) and analyzed. All of the eight participating firms except one calculated correct clearance values. The reason for the failure in one case turned out to be a bug in the computer program. This pilot study has demonstrated that it is possible to establish certain technical standards for the clinical software in nuclear medicine but also to detect and correct errors. (orig.) [de

  3. A hybrid flower pollination algorithm based modified randomized location for multi-threshold medical image segmentation.

    Science.gov (United States)

    Wang, Rui; Zhou, Yongquan; Zhao, Chengyan; Wu, Haizhou

    2015-01-01

    Multi-threshold image segmentation is a powerful image processing technique that is used for the preprocessing of pattern recognition and computer vision. However, traditional multilevel thresholding methods are computationally expensive because they involve exhaustively searching the optimal thresholds to optimize the objective functions. To overcome this drawback, this paper proposes a flower pollination algorithm with a randomized location modification. The proposed algorithm is used to find optimal threshold values for maximizing Otsu's objective functions with regard to eight medical grayscale images. When benchmarked against other state-of-the-art evolutionary algorithms, the new algorithm proves itself to be robust and effective through numerical experimental results including Otsu's objective values and standard deviations.

  4. Homogeneous SLOWPOKE reactors for Mo-99/Tc-99m production in North America

    Energy Technology Data Exchange (ETDEWEB)

    Hilborn, J.W., E-mail: hilbovanw@sympatico.ca [Deep River, Ontario (Canada); Bonin, H.W. [Royal Military College of Canada, Kingston, Ontario (Canada)

    2014-07-01

    The 15 month shutdown of NRU in 2009 - 2010 caused an overall isotope shortage of approximately 30%; and in North America, the annual Tc-99m demand decreased from an estimated 20 million unit doses to about 15 million unit doses. Mo-99/Tc-99m is produced from HEU targets, irradiated in NRU for 11 days, and after chemical removal of uranium it is shipped to Nordion in Kanata, Ontario. Nordion further purifies the material and sends it to Lantheus Medical Imaging in the USA for manufacture of Mo-99 generators, which are then distributed to hundreds of hospital radiopharmacies throughout North America. One other American company, Covidien, manufactures and distributes Mo-99 generators like Lantheus, but they import bulk Mo-99 from Europe or South Africa. At the hospitals, Tc-99m is chemically extracted daily from the Mo-99 generators and loaded into syringes for immediate clinical use. Fortuitously, the 66 hour half-life of Mo-99 allows the replenishment of Tc-99m in the generator over a growth period of about 20 hours; and a generator can be 'milked' daily for up to two weeks. A more efficient model is the direct production and distribution of Tc-99m unit doses to regional hospitals from 10 'industrial' radiopharmacies located at existing licensed reactor sites in North America. A 20 kW homogeneous SLOWPOKE reactor at each site would deliver 15 litres of irradiated uranyl sulphate fuel solution daily to industrial-scale hot cells for extraction of Mo-99, which would be incorporated in large Mo-99/Tc-99m generators for extraction of Tc-99m five days a week; and the Low Enriched Uranium (LEU) would be recycled. Each automated hot-cell facility would be designed to load up to 7,000 Tc-99m syringes daily, for courier delivery to all of the Nuclear Medicine hospitals within a 3 hour average range by road transport. Typically, the delivered doses would be in the range 10 to 30 mCi. Assuming an average unit dose of 25 mCi at the hospital and 5 x 52

  5. 99Mo production for using in the nuclear medicine in 99mTc generators

    International Nuclear Information System (INIS)

    Kurenkov, N.V.; Chuvilin, D.Yu.

    1999-01-01

    The review of methods and advanced technologies for obtaining 99 Mo in nuclear reactors is presented. The 99 Mo isotope is used for preparing the 99m Tc generators, widely applied in nuclear medicine. The reactor method for obtaining 99 Mo is based on the 98 Mo(n, γ) 99 Mo radiation capture reaction and 235 U fission reaction under the effect of the 235 U (n, f) 99 Mo reaction. The results of studies on obtaining 99 Mo on the charged particles accelerators, mainly, on the proton beam and under the effect of photonuclear reaction is also described. The data on the 99 Mo real consumption and forecast for its application in different regions of the world from 1994 up to 2006 are presented [ru

  6. Development of 99mTc extraction techniques from 99Mo by (n,γ) reaction

    International Nuclear Information System (INIS)

    Kimura, Akihiro; Hori, Naohiko; Tsuchiya, Kunihiko; Ishihara, Masahiro; Yamabayashi, Hisamichi; Tanase, Masakazu; Fujisaki, Saburo; Sato, Yuichi

    2010-11-01

    Investigation of production method of 99 Mo by (n, γ) reaction, where the processing is relatively simple and generating less amount of radioactive waste, is conducted in the Neutron Irradiation and Testing Reactor Center. The 99 Mo is adsorbed to highly efficient adsorbent PZC after neutron irradiation and 99m Tc is eluted. However, radioactivity concentration of the 99m Tc solution obtained from PZC column loaded with 99 Mo derived by (n, γ) method is lower than that obtained from alumina column with 99 Mo by (n, f) method due to extremely low specific activity of (n, f) 99 Mo. Therefore, it is necessary to develop technique for increasing the amount of 99 Mo and the 99m Tc solution of high radioactivity concentration (minimum: 1Ci/ cm 3 ). In this study, the preliminary fabrication tests using high density MoO 3 pellets were carried out to increase the production of 99 Mo. The method of concentrating 99m Tc solution through solvent extraction with MEK was investigated and a device for this concentration process was also developed. In the preliminary tests of the MoO 3 pellets, the pellets having high density were successfully fabricated by the SPS method. Additionally, it was ascertained that the pellets can be dissolved with 6M-NaOH solution completely. The test for 99 Mo adsorption followed by 99m Tc elution using PZC was carried out. As the result, amount of Mo adsorbed to 1g-PZC was about 250mg, and 99m Tc yield was about 80%. In the concentration test using Re solution instead of 99m Tc solution, it was ascertained that the concentration efficiency is higher than 80% of the theoretical value. A concentration device for 99m Tc solution could be realized based on the method employed in the present experiments. The outcomes of development of 99m Tc extraction techniques from 99 Mo by (n,γ) reaction was reviewed in this paper, and the contents were presented in the 3rd International Symposium on Material Test Reactors. (author)

  7. 14 CFR 99.1 - Applicability.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Applicability. 99.1 Section 99.1... AND GENERAL OPERATING RULES SECURITY CONTROL OF AIR TRAFFIC General § 99.1 Applicability. (a) This... Identification Zone (ADIZ) designated in subpart B. (b) Except for §§ 99.7, 99.13, and 99.15 this subpart does...

  8. Uncertainty analysis of 99mTc-HEPIDA liver clearance determination

    International Nuclear Information System (INIS)

    Surma, M. J.

    2005-01-01

    The aim of the study was to obtain information on the accuracy and precision of 99mT c-HEPIDA hepatic (Cl H p) and plasma (Cl P l) clearances and selection of an appropriate estimator of the measurement uncertainty of a single determination of these quantities. In a simulation (Monte Carlo) experiment, it was assumed that the recorded results of plasma and hepatic clearances, as obtained from 185 patients, provided authentic information about 99mT c-HEPIDA behaviour in the body over a wide range of the clearances studied. The time-course 99mT c-HEPIDA concentration in blood plasma has been described by means of biexponential function with parameter values derived for each patient. For each patient, using these data and urinary excretion data, there had been 5000 simulations performed; in each of the latter, the directly measured numbers have been substituted by simulated ones, obtained by means of varying the real ones, using random generated values. These reflected errors of plasma and radioactive standard pipetting (from 1 to 5%) and stochasticity of counting radioactive decay (1%). The time of blood sampling and urine voiding was also varied, assuming realistic uncertainty. The varied values were then used for computation of the simulated clearances. From the 5000 calculated clearances for each patient, mean-values were calculated, as well as mean standard errors, standard deviations and mean uncertainty of measurements using a widely accepted rule of partial error propagation, and, in addition, a modified rule of the latter. Accuracy of clearance (Cl P l, Cl H p, Cl U r) determination was assessed on the basis of comparison of mean values from simulations with those from directly recorded values. Precision was identified with standard deviation of each of the 5000 simulations. The uncertainty thus obtained was compared with results of calculated traditional and modified uncertainty. There was good agreement between standard deviation of the simulations with

  9. Comparison of 30-2 Standard and Fast programs of Swedish Interactive Threshold Algorithm of Humphrey Field Analyzer for perimetry in patients with intracranial tumors.

    Science.gov (United States)

    Singh, Manav Deep; Jain, Kanika

    2017-11-01

    To find out whether 30-2 Swedish Interactive Threshold Algorithm (SITA) Fast is comparable to 30-2 SITA Standard as a tool for perimetry among the patients with intracranial tumors. This was a prospective cross-sectional study involving 80 patients aged ≥18 years with imaging proven intracranial tumors and visual acuity better than 20/60. The patients underwent multiple visual field examinations using the two algorithms till consistent and repeatable results were obtained. A total of 140 eyes of 80 patients were analyzed. Almost 60% of patients undergoing perimetry with SITA Standard required two or more sessions to obtain consistent results, whereas the same could be obtained in 81.42% with SITA Fast in the first session itself. Of 140 eyes, 70 eyes had recordable field defects and the rest had no defects as detected by either of the two algorithms. Mean deviation (MD) (P = 0.56), pattern standard deviation (PSD) (P = 0.22), visual field index (P = 0.83) and number of depressed points at P 0.5% on MD and PSD probability plots showed no statistically significant difference between two algorithms. Bland-Altman test showed that considerable variability existed between two algorithms. Perimetry performed by SITA Standard and SITA Fast algorithm of Humphrey Field Analyzer gives comparable results among the patients of intracranial tumors. Being more time efficient and with a shorter learning curve, SITA Fast my be recommended as a standard test for the purpose of perimetry among these patients.

  10. Use of 99mTc from a commercial 99Mo/9mTc generator as yield tracer for the determination of 99Tc at low levels

    DEFF Research Database (Denmark)

    Hou, Xiaolin; Jensen, Mikael; Nielsen, Sven Poul

    2007-01-01

    The concentrations of Tc-99 and impurity radionuclides in the Tc-99m tracer solution obtained from a commercial Mo-99/Tc-99m generator were measured by gamma spectrometry and liquid scintillation counting. Mo-99 and Ru-103 were found in the Tc-99m eluate. A simple separation using two extra alumina...... cartridges was investigated to purify the eluate to obtain a suitable Tc-99m tracer with low Tc-99 concentration. The activity ratio of Tc-99/Tc-99m in the prepared Tc-99m solution is lower than 15 x 10(-9), which is higher than the theoretical ratio of less than 10 x 10(-9). The possible reason is discussed....... The Tc-99 in the 20 kBq spiked Tc-99m tracer was found to be less than 0.3mBq, which is lower than the detection limit of the radiometric method used for environmental samples. The purified Tc-99m eluate is used as yield tracer for the determination of low levels of Tc-99 in environmental samples. (c...

  11. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Tagami, K. E-mail: k_tagami@nirs.go.jp; Uchida, S.; Hamilton, T.; Robison, W

    2000-07-15

    Extraction techniques for recovery of technetium-99 ({sup 99}Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (M1) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for {sup 99}Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the {sup 99}Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The {sup 99}Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g{sup -1} dry weight (dw). The limit of detection for {sup 99}Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g{sup -1} dw under standard operating conditions.

  12. Evaluation of a radioactive and fluorescent hybrid tracer for sentinel lymph node biopsy in head and neck malignancies: prospective randomized clinical trial to compare ICG-{sup 99m}Tc-nanocolloid hybrid tracer versus {sup 99m}Tc-nanocolloid

    Energy Technology Data Exchange (ETDEWEB)

    Stoffels, Ingo; Leyh, Julia; Schadendorf, Dirk; Klode, Joachim [University Hospital Essen University of Duisburg-Essen, Department of Dermatology, Venerology and Allergology, Essen (Germany); University Duisburg-Essen, West German Cancer Center, Essen (Germany); German Cancer Consortium (DKTK), Essen (Germany); Poeppel, Thorsten [University Hospital Essen University of Duisburg-Essen, Department of Nuclear Medicine, Essen (Germany)

    2015-10-15

    There is some controversy about the value of sentinel lymph node excision (SLNE) in patients with head and neck malignancies. The gold standard for detection and targeted extirpation of the SLN is lymphoscintigraphy with {sup 99m}Tc-nanocolloid. The purpose of this prospective randomized study was to analyse the feasibility and clinical benefit of a hybrid tracer comprising the near-infrared (NIR) fluorescent indocyanine green (ICG) and {sup 99m}Tc-nanocolloid (ICG-{sup 99m}Tc-nanocolloid) in direct comparison with standard {sup 99m}Tc-nanocolloid for guiding SLNE in patients with head and neck cutaneous malignancies. We analysed the data from 40 clinically lymph node-negative patients with melanoma, high-risk cutaneous squamous cell carcinoma, Merkel cell carcinoma or sweat gland carcinoma who underwent SLNE with ICG-{sup 99m}Tc-nanocolloid (cohort A) or with the standard {sup 99m}Tc-nanocolloid (cohort B). Overall SLNs were identified preoperatively in all 20 patients (100 %) in cohort A and in 18 of 20 patients (90 %) in cohort B. The SLN basin was detected preoperatively in 18 patients (90 %) in cohort A and also in 18 patients (90 %) in cohort B. SLNs were identified intraoperatively in all 20 patients (100 %) in cohort A and in 19 patients (95 %) in cohort B (p = 0.487). Metastatic SLNs were detected in 9 patients (22.5 %), 3 (15.0 %) in cohort A and 6 (30.0 %) in cohort B (p = 0.228). The hybrid tracer ICG-{sup 99m}Tc-nanocolloid is an innovative imaging tracer, reliably and readily providing additional information for the detection and excision of SLN in the head and neck region. Therefore, SLNE with combined radioactive and NIR fluorescence guidance is an attractive option for improving the SLN detection rate in patients with cutaneous head and neck malignancies. (orig.)

  13. Furnace System Testing to Support Lower-Temperature Stabilization of High Chloride Plutonium Oxide Items at the Hanford Plutonium Finishing Plant

    International Nuclear Information System (INIS)

    Schmidt, Andrew J.; Gerber, Mark A.; Fischer, Christopher M.; Elmore, Monte R.

    2003-01-01

    High chloride content plutonium (HCP) oxides are impure plutonium oxide scrap which contains NaCl, KCl, MgCl2 and/or CaCl2 salts at potentially high concentrations and must be stabilized at 950 C per the DOE Standard, DOE-STD-3013-2000. The chlorides pose challenges to stabilization because volatile chloride salts and decomposition products can corrode furnace heating elements and downstream ventilation components. Thermal stabilization of HCP items at 750 C (without water washing) is being investigated as an alternative method for meeting the intent of DOE STD 3013-2000. This report presents the results from a series of furnace tests conducted to develop material balance and system operability data for supporting the evaluation of lower-temperature thermal stabilization

  14. Preparation of a gel of zirconium molybdate for use in the generators of 99 Mo - 99m Tc prepared with 99 Mo produced by the 98 Mo(n,γ)99 Mo reaction

    International Nuclear Information System (INIS)

    Osso Junior, Joao A.; Lima, Ana Lucia V.P.; Silva, Nestor C. da; Nieto, Renata C.; Velosa, Adriana C. de

    1998-01-01

    IPEN develops a project concerning the preparation of a gel of Zirconium Molybdate for use in the generators of 99 Mo- 99m Tc . 99m Tc is the most used radioisotope in nuclear medicine diagnosis procedures and nowadays the generators are being prepared with imported 99 Mo, produced by 235 U fission. The production of 99 Mo by the 98 Mo(n, γ) 99 Mo reaction is now possible because of the power upgrade of IPEN's IEA-R1 reactor, from 2 to 5 MW. This work describes the preparation method of Zirconium Molybdate gel that will be used in the 99 Mo- 99m Tc generators. The gel is prepared by the chemical reaction between Mo, in Mo O 3 form, and Zr, in Zr O Cl 2 .8H 2 O form. After the reaction, the gel is filtered, dried and cracked with saline solution. The product is then loaded into glass columns for use as 99m Tc generator. The results showed the good quality of the gel prepared at laboratory level and of the generators evaluated. (author)

  15. Behavior of technetium-99 in soils and plants. Final report, April 1, 1974--December 31, 1978

    Energy Technology Data Exchange (ETDEWEB)

    Gast, R.G.; Landa, E.R.; Thorvig, L.J.; Grigal, D.F.; Balogh, J.C.

    1979-01-01

    Studies described in this report were aimed at establishing the magnitude and mechanisms of /sup 99/Tc sorption by soils and uptake by plants. Results show that /sup 99/Tc was sorbed from solution over a period to two to five weeks by 8 of 11 soils studies. The slow rate of sorption, the lack of sorption by low organic matter soils, the elimination of sorption following sterilization and increased sorption following addition of dextrose all point to a microbial role in the sorption process. However, it has not been established whether this is a direct or indirect role nor is it possible to clearly predict the conditions under which sorption will occur. Results of plant uptake studies show that /sup 99/Tc can be taken up and translocated into the photosynthetic tissue of higher plants with concentrations in seeds being much less than in vegetative tissue. Technetium-99 was also shown to be toxic to plants at low concentrations and evidence suggests that this is a chemically rather than radiologically induced toxicity. However, this remains to be completely resolved as well as whether there is a threshold level of /sup 99/Tc required before toxicity occurs. Studies of short-term, dynamic, aerobic systems indicated that /sup 99/Tc moves through the soil as a relatively large anion exhibiting characteristic miscible displacement with some asymmetric tailing. /sup 99/Tc exhibits greater retention that C1/sup -/, which may be attributed statistically to weak complexion by organic matter. It is unlikely that this retention phenomenon is related to the static sorption activity reported in the first part of this study.

  16. An ulra-low-energy/frame multi-standard JPEG co-processor in 65nm CMOS with sub/near-threshold power supply.

    NARCIS (Netherlands)

    Pu, Yu; Pineda de Gyvez, J.; Corporaal, H.; Ha, Y.

    2009-01-01

    Many digital ICs can benefit from sub/near threshold operations that provide ultra-low-energy/operation for long battery lifetime. In addition, sub/near threshold operation largely mitigates the transient current hence lowering the ground bounce noise. This also helps to improve the performance of

  17. Double-adjustment in propensity score matching analysis: choosing a threshold for considering residual imbalance.

    Science.gov (United States)

    Nguyen, Tri-Long; Collins, Gary S; Spence, Jessica; Daurès, Jean-Pierre; Devereaux, P J; Landais, Paul; Le Manach, Yannick

    2017-04-28

    Double-adjustment can be used to remove confounding if imbalance exists after propensity score (PS) matching. However, it is not always possible to include all covariates in adjustment. We aimed to find the optimal imbalance threshold for entering covariates into regression. We conducted a series of Monte Carlo simulations on virtual populations of 5,000 subjects. We performed PS 1:1 nearest-neighbor matching on each sample. We calculated standardized mean differences across groups to detect any remaining imbalance in the matched samples. We examined 25 thresholds (from 0.01 to 0.25, stepwise 0.01) for considering residual imbalance. The treatment effect was estimated using logistic regression that contained only those covariates considered to be unbalanced by these thresholds. We showed that regression adjustment could dramatically remove residual confounding bias when it included all of the covariates with a standardized difference greater than 0.10. The additional benefit was negligible when we also adjusted for covariates with less imbalance. We found that the mean squared error of the estimates was minimized under the same conditions. If covariate balance is not achieved, we recommend reiterating PS modeling until standardized differences below 0.10 are achieved on most covariates. In case of remaining imbalance, a double adjustment might be worth considering.

  18. An energy-based body temperature threshold between torpor and normothermia for small mammals.

    Science.gov (United States)

    Willis, Craig K R

    2007-01-01

    Field studies of use of torpor by heterothermic endotherms suffer from the lack of a standardized threshold differentiating torpid body temperatures (T(b)) from normothermic T(b)'s. This threshold can be more readily observed if metabolic rate (MR) is measured in the laboratory. I digitized figures from the literature that depicted simultaneous traces of MR and T(b) from 32 respirometry runs for 14 mammal species. For each graph, I quantified the T(b) measured when MR first began to drop at the onset of torpor (T(b-onset)). I used a general linear model to quantify the effect of ambient temperature (T(a)) and body mass (BM) on T(b-onset). For species lighter than 70 g, the model was highly significant and was described by the equation Tb-onset=(0.055+/-0.014)BM+(0.071+/-0.031)Ta+(31.823+/-0.740). To be conservative, I recommend use of these model parameters minus 1 standard error, which modifies the equation to Tb-onset-1 SE=(0.041)BM+(0.040)Ta+31.083. This approach provides a standardized threshold for differentiating torpor from normothermia that is based on use of energy, the actual currency of interest for studies of torpor in the wild. Few laboratory studies have presented the time-course data required to quantify T(b-onset), so more data are needed to validate this relationship.

  19. Thermal Analysis Of A 9975 Package In A Facility Fire Accident

    International Nuclear Information System (INIS)

    Gupta, N.

    2011-01-01

    Surplus plutonium bearing materials in the U.S. Department of Energy (DOE) complex are stored in the 3013 containers that are designed to meet the requirements of the DOE standard DOE-STD-3013. The 3013 containers are in turn packaged inside 9975 packages that are designed to meet the NRC 10 CFR Part 71 regulatory requirements for transporting the Type B fissile materials across the DOE complex. The design requirements for the hypothetical accident conditions (HAC) involving a fire are given in 10 CFR 71.73. The 9975 packages are stored at the DOE Savannah River Site in the K-Area Material Storage (KAMS) facility for long term of up to 50 years. The design requirements for safe storage in KAMS facility containing multiple sources of combustible materials are far more challenging than the HAC requirements in 10 CFR 71.73. While the 10 CFR 71.73 postulates an HAC fire of 1475 F and 30 minutes duration, the facility fire calls for a fire of 1500 F and 86 duration. This paper describes a methodology and the analysis results that meet the design limits of the 9975 component and demonstrate the robustness of the 9975 package.

  20. Preparation of i.v. 99mTc radiopharmaceuticals from spent moly 99Mo

    International Nuclear Information System (INIS)

    Noronha, O.P.D.

    1998-01-01

    Full text: Expiry dating is an important quality assurance precept in (radio) pharmacy. There are occasions when for the sake of patient service one may be forced to continue using an over aged source of 99 Mo to generate 99m Tc beyond 7d, especially when there is short/no supply of 99 Mo, (In the early days the expiry date was 3 d or 3 extractions, whichever one was earlier). With the passage of time a few physico-chemical changes (apart from decay) do occur in the 99 Mo/ 99m Tc milieu. The cocktail also begins to contain traces of carried over MEK which is subjected to strong β-, γ irradiation. These impurity (in trace amounts) is soluble in MEK and even, to an extent, in aqueous media. Furthermore, the concentrated impurity tends to seemingly increase in the bulk 99m TcO 4 - since one is compelled to leach TcO 4 - in lower volume of saline. On many occasions we have been constrained to extend the use of 99 Mo beyond 7 - 14 d. Adequate activities were obtained by pooling the previous week's lot of 99 Mo with the current over aged lot. On a few occasions over the past 26 years we have used 99 Mo much beyond 14 d and 2 - 3 occasions for 26 - 28 d (i.e. >10 t 1 /2 of 99 Mo). On each of these occasions the purity of 99m TcO- 4 was ascertained by pharmacopoeial procedures. It was found that despite depleting activities, the purity was not compromised and the trace impurities, even if present, did not cause any interference. We have profitably utilised the bulk TcO- 4 to formulate a variety of i.v. dosage forms of 99m Tc radiodiagnostics. The following strategy was adopted for the patient services - the agents requiring larger activity levels/patients dose were made available in the earlier period, the other during the latter half. It is concluded that pure 99m TcO- 4 can be obtained over the entire useful life-period of 99 Mo, even > 10t l/2

  1. A comparative study of 99Tcm-tetrofosmin and 99Tcm-MIBI myocardial imaging

    International Nuclear Information System (INIS)

    Zhao Kui; Chen Peng; Zhang Furong; Shen Wenhua

    2001-01-01

    Objective: To evaluate the value of 99 Tc m -tetrofosmin myocardial imaging for detecting coronary artery disease. Methods: Twenty-seven patients underwent 99 Tc m -tetrofosmin SPECT, twenty-six patients underwent 99 Tc m -MIBI SPECT; coronary angiography was performed on patients included in both groups (≥50% luminal diameter stenosis was considered significant coronary stenosis). Results: 99 Tc m -tetrofosmin produced high quality myocardial images from 30 min to several hours postinjection, the outlines of myocardial perfusion images provided by 99 Tc m -tetrofosmin imaging were clearly discernible. One-day exercise/rest 99 Tc m -tetrofosmin myocardial perfusion imaging was feasible and had a high sensitivity for detection of coronary artery disease. Sensitivities of 99 Tc m -tetrofosmin SPECT and 99 Tc m -MIBI SPECT for detecting coronary artery disease were 90% and 94%, respectively. The 95% confidence limits of both sensitivities were 68.65% - 98.77% and 72.33% - 99.86%, respectively; the positive predictive values of both imaging agents were 90.0% and 89.5%, respectively, the 95% confidence limits of those were 68.38% - 98.77% and 72.33% - 99.86% respectively; the positive predictive values of both imaging agents were 90.0% and 89.5%, respectively, the 95% confidence limits of those were 68.38% - 98.77% and 66.38% - 98.70%, respectively; efficiencies of both imaging agents were 85.2% and 88.5%, respectively. The 95% confidence limits of both efficiencies were 65.81% - 95.78% and 69.44 - 98.70%, respectively. The specificity for both imaging agents was 71% and 75%. There was no significant difference among above results (P > 0.05). No ECG abnormalities were found following the injection of 99 Tc m -tetrofosmin SPECT. There were no drug-related effects on blood pressure, heart rate and body temperature. This experiment failed to provide the negative predictive value of the myocardial perfusion imaging with 99 Tc m -tetrofosmin because that few patients with

  2. Synthesis and characterization of zirconium molybdates of 99 Mo/99m Tc generators

    International Nuclear Information System (INIS)

    Contreras R, A.; Monroy G, F.; Diaz A, L.V.

    2002-01-01

    The zirconium molybdates are gels which are used as cation exchangers in the production of 99 Mo/ 99m Tc generators. The synthesis method and the characterization of these gels by thermogravimetry, infrared spectroscopy and X-ray diffraction is presented with the purpose of finding which the factors are that influence in the efficiency of the 99m Tc production. The results show that the quantity of molecular water contained in gel, is possibly the cause of variations of the efficiencies of the 99 Mo/ 99m Tc generator. (Author)

  3. (99m)Tc-Annexin A5 quantification of apoptotic tumor response: a systematic review and meta-analysis of clinical imaging trials.

    Science.gov (United States)

    Belhocine, Tarik Z; Blankenberg, Francis G; Kartachova, Marina S; Stitt, Larry W; Vanderheyden, Jean-Luc; Hoebers, Frank J P; Van de Wiele, Christophe

    2015-12-01

    uptake following treatment was considered a significant threshold for an apoptotic tumor response (partial response, complete response). In three other phase I/II clinical trials, increases of ≥28%, ≥42% and ≥47% in uptake following treatment were found to be the mean cut-off levels in responders. In a phase II/III multicenter clinical trial, an increase of ≥23% in uptake following treatment was found to be the minimum cut-off level for a tumor response. In one clinical trial, no significant difference in (99m)Tc-annexin A5 uptake in terms of %ID was found in healthy tissues after chemotherapy compared to baseline. In two other clinical trials, intraobserver and interobserver measurements of (99m)Tc-annexin A5 tumor uptake were found to be reproducible (mean difference Tc-annexin A5 imaging has been investigated in clinical trials for the assessment of apoptotic tumor responses. This meta-analysis showed a high pooled PPV and a moderate pooled NPV with ΔU cut-off values ranging between 20% and 30%. Standardization of quantification and harmonization of results are required for high-quality clinical research. A standardized uptake value score (SUV, ΔSUV) using quantitative SPECT/CT imaging may be a promising approach to the simple, reproducible and semiquantitative assessment of apoptotic tumor changes.

  4. Comparative evaluation of 131I-hippuran and sup(99m)Tc-DTPA for renal function test

    International Nuclear Information System (INIS)

    Kempi, V.; Persson, R.B.R.; Svensson, L.

    1975-07-01

    131 I-labelled Hippuran and sup(99m)Tc-labelled DTPA have been compared as substances used for renal function tests. The radiation absorbed dose for 131 I-Hippuran and sup(99m)Tc-DTPA to different organs of an adult standard man is given i a table, showing considerably lower doses for sup(99m)Tc-DTPA. Good agreement was found between the renographic curves obtained with 131 I-Hippuran and sup(99m)Tc-DTPA compared to 131 I-Hippuran excellent scintiphotos of the kidney and also of the upper urinary ways were obtained with sup(99m)Tc-DTPA. With sup(99m)Tc-DTPA, repeated examinations make it possible to follow the development of a disease without great radiation risk to the patient (K.K.)

  5. Synthesis and characterization of zirconium molybdates of {sup 99} Mo/{sup 99m} Tc generators; Sintesis y caracterizacion de molibdatos de zirconio de generadores {sup 99} Mo/{sup 99m} Tc

    Energy Technology Data Exchange (ETDEWEB)

    Contreras R, A.; Monroy G, F.; Diaz A, L.V. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The zirconium molybdates are gels which are used as cation exchangers in the production of {sup 99} Mo/{sup 99m} Tc generators. The synthesis method and the characterization of these gels by thermogravimetry, infrared spectroscopy and X-ray diffraction is presented with the purpose of finding which the factors are that influence in the efficiency of the {sup 99m} Tc production. The results show that the quantity of molecular water contained in gel, is possibly the cause of variations of the efficiencies of the {sup 99} Mo/{sup 99m} Tc generator. (Author)

  6. Disintegration rate of Tc -99m and In -111 radioactive solutions in coincidence systems

    International Nuclear Information System (INIS)

    Brito, Andreia Barreto de

    2011-01-01

    The 111 In and 99 mTc standardization in a 4πβ-γ coincidence system is described. The 111 In was produced by the reaction of 111 Cd (p, n) 111 In in the cyclotron. The 111 In decays with a half life of 2.8 days by electron capture process, populating the excited levels of 111 Cd, emitting two main gamma rays with energies of 171 keV and 245 keV. The 99m Tc decay with a half life of 6.007 h for isomeric transition, from the radioactive decay of 99 Mo. 111 In standardization was carried out in a 4πβ-γ system, consisted of a gas flow proportional counter with 4π geometry coupled to a pair of NaI(Tl) scintillation counter with conventional electronics. The gamma window was set comprising the (171 keV + 245 keV) total absorption energy peaks. The choice of the window was based on the analysis of the extrapolation curves prediction, obtained by Monte Carlo simulation. The 99 mTc standardization has been accomplished by the 4πβ-γ coincidence method using a thin window proportional counter in a 4π geometry coupled to a single NaI(Tl) scintillation counter. The beta efficiency was varied by electronic discrimination using a software coincidence counting system (SCS). Two windows were selected for the gamma channel: one at 140 keV gamma ray and the other at 20 keV X ray total absorption peaks. The result of the experimental activity of 111 In two solutions agree with the results obtained by Monte Carlo simulation. The experimental activities of 99m Tc for the two gamma windows are in agreement within the experimental uncertainty, indicating that the adopted methodology is adequate. (author)

  7. Threshold Signature Schemes Application

    Directory of Open Access Journals (Sweden)

    Anastasiya Victorovna Beresneva

    2015-10-01

    Full Text Available This work is devoted to an investigation of threshold signature schemes. The systematization of the threshold signature schemes was done, cryptographic constructions based on interpolation Lagrange polynomial, elliptic curves and bilinear pairings were examined. Different methods of generation and verification of threshold signatures were explored, the availability of practical usage of threshold schemes in mobile agents, Internet banking and e-currency was shown. The topics of further investigation were given and it could reduce a level of counterfeit electronic documents signed by a group of users.

  8. Combined threshold and transverse momentum resummation for inclusive observables

    International Nuclear Information System (INIS)

    Muselli, Claudio; Forte, Stefano; Ridolfi, Giovanni

    2017-01-01

    We present a combined resummation for the transverse momentum distribution of a colorless final state in perturbative QCD, expressed as a function of transverse momentum p T and the scaling variable x. Its expression satisfies three requirements: it reduces to standard transverse momentum resummation to any desired logarithmic order in the limit p T →0 for fixed x, up to power suppressed corrections in p T ; it reduces to threshold resummation to any desired logarithmic order in the limit x→1 for fixed p T , up to power suppressed correction in 1−x; upon integration over transverse momentum it reproduces the resummation of the total cross cross at any given logarithmic order in the threshold x→1 limit, up to power suppressed correction in 1−x. Its main ingredient, and our main new result, is a modified form of transverse momentum resummation, which leads to threshold resummation upon integration over p T , and for which we provide a simple closed-form analytic expression in Fourier-Mellin (b,N) space. We give explicit coefficients up to NNLL order for the specific case of Higgs production in gluon fusion in the effective field theory limit. Our result allows for a systematic improvement of the transverse momentum distribution through threshold resummation which holds for all p T , and elucidates the relation between transverse momentum resummation and threshold resummation at the inclusive level, specifically by providing within perturbative QCD a simple derivation of the main consequence of the so-called collinear anomaly of SCET.

  9. Combined threshold and transverse momentum resummation for inclusive observables

    Energy Technology Data Exchange (ETDEWEB)

    Muselli, Claudio; Forte, Stefano [Tif Lab, Dipartimento di Fisica, Università di Milano and INFN, Sezione di Milano,Via Celoria 16, I-20133 Milano (Italy); Ridolfi, Giovanni [Dipartimento di Fisica, Università di Genova and INFN, Sezione di Genova,Via Dodecaneso 33, I-16146 Genova (Italy)

    2017-03-21

    We present a combined resummation for the transverse momentum distribution of a colorless final state in perturbative QCD, expressed as a function of transverse momentum p{sub T} and the scaling variable x. Its expression satisfies three requirements: it reduces to standard transverse momentum resummation to any desired logarithmic order in the limit p{sub T}→0 for fixed x, up to power suppressed corrections in p{sub T}; it reduces to threshold resummation to any desired logarithmic order in the limit x→1 for fixed p{sub T}, up to power suppressed correction in 1−x; upon integration over transverse momentum it reproduces the resummation of the total cross cross at any given logarithmic order in the threshold x→1 limit, up to power suppressed correction in 1−x. Its main ingredient, and our main new result, is a modified form of transverse momentum resummation, which leads to threshold resummation upon integration over p{sub T}, and for which we provide a simple closed-form analytic expression in Fourier-Mellin (b,N) space. We give explicit coefficients up to NNLL order for the specific case of Higgs production in gluon fusion in the effective field theory limit. Our result allows for a systematic improvement of the transverse momentum distribution through threshold resummation which holds for all p{sub T}, and elucidates the relation between transverse momentum resummation and threshold resummation at the inclusive level, specifically by providing within perturbative QCD a simple derivation of the main consequence of the so-called collinear anomaly of SCET.

  10. Thresholds in radiobiology

    International Nuclear Information System (INIS)

    Katz, R.; Hofmann, W.

    1982-01-01

    Interpretations of biological radiation effects frequently use the word 'threshold'. The meaning of this word is explored together with its relationship to the fundamental character of radiation effects and to the question of perception. It is emphasised that although the existence of either a dose or an LET threshold can never be settled by experimental radiobiological investigations, it may be argued on fundamental statistical grounds that for all statistical processes, and especially where the number of observed events is small, the concept of a threshold is logically invalid. (U.K.)

  11. Evaluation of the absorbed dose to the kidneys due to Tc99m (DTPA) / Tc99m (Mag3) and Tc99m (Dmsa)

    International Nuclear Information System (INIS)

    Vasquez A, M.; Murillo C, F.; Castillo D, C.; Rocha J, J.; Sifuentes D, Y.; Sanchez S, P.; Idrogo C, J.; Marquez P, F.

    2015-10-01

    The absorbed dose in the kidneys of adult patients has been assessed using the biokinetics of radiopharmaceuticals containing Tc 99m (DTPA) / Tc 99m (Mag3) or Tc 99m (Dmsa).The absorbed dose was calculated using the formalism MIRD and the Cristy-Eckerman representation for the kidneys. The absorbed dose to the kidneys due to Tc 99m (DTPA) / Tc 99m (Mag3), are given by 0.00466 mGy.MBq -1 / 0.00339 mGy.MBq -1 . Approximately 21.2% of the absorbed dose is due to the bladder (content) and the remaining tissue, included in biokinetics of Tc 99m (DTPA) / Tc 99m (Mag3). The absorbed dose to the kidneys due to Tc 99m (Dmsa) is 0.17881 mGy.MBq -1 . Here, 1.7% of the absorbed dose is due to the bladder, spleen, liver and the remaining tissue, included in biokinetics of Tc 99m (Dmsa). (Author)

  12. Installation of Tc-99m generator manufacturing facilities

    International Nuclear Information System (INIS)

    Shin, B. C.; Choung, W. M.; Park, J. H.; Park, S. H.; Kim, S. J.; Park, K. B.

    2004-01-01

    For the characteristics of radiopharmaceuticals, the manufacturing facility should be complied with the radiation safety standards for operators as well as GMP (Good Manufacturing Practice) cleanness standards for production. We intensively modified the existing Radioisotope production facilities, which were installed only in radiation safety points of view, to meet cleanness criteria. And the concept of multi-barrier buffer zones was introduced to apply negative air pressure for hot cell with first priority and to continue relative positive air pressure for clean room. The manufacturing area for Tc-99m Generator can be entered only through a second change. The doors of each change area are interlocked to maintain air pressure differentials. The pass box for material transfer are also interlocked so that only one side may be opened at any one time to keep cleanness. Two door-type autoclave was installed crossing the wall between preparing room and aseptic room to keep cleanness after sterilization. Three lead hot cells were installed and final inspection including gamma survey test were performed. The clean room was installed and TAB for this facility was performed in order to acquire the necessary air flow. The filter bank for filtration of exhausted radiation air was installed and its efficiency test was performed. In this facility, radiation shielding utilities and manufacturing instruments were set up and their operating manuals were documented. Efficiency tests for every utilities and instruments were satisfied and the approval for use of the facilities was achieved from MOST (Ministry of Science and Technology). The Sam Young Unitech, the lessee of the facilities set up the equipment in the hot cell, which is needed to produce Tc-99m Generator, supported by IPPE in Russia. They are composing the systems complied with the guidelines and the regulations, and keep in contact to KFDA for acquiring its approval. It is expected to produce Tc-99m Generator within

  13. Separation of sup(99m)Tc from 99Mo through a hydrous zirconium oxide column

    International Nuclear Information System (INIS)

    Mengatti, J.

    1980-01-01

    The preparation of 99 Mo-,sup(99m)Tc generator based on the adsorption of 99 Mo on hydrous zirconium oxide column, employing the in exchange technique, is described. The adsorption of 99 Mo on hydrous zirconium oxide (HZO) and the separation of sup(99m)Tc, generated by the decay of 99 Mo with saline solution, are analised. The sup(99m)Tc separation yield, pH of the eluted solution, aspect of the elution curve and the adsorption of 99 Mo on hydrous zirconium oxide calcined at 800 0 C are studied. The chemical and radioactive purities of the final product are analysed and the variation of the elution yield for successive elutions is studied. (Author) [pt

  14. Studies of techniques for the post-elution concentration of 99mTc obtained from gel type 99Mo/99mTc generators

    International Nuclear Information System (INIS)

    Suzuki, Katia Noriko

    2009-01-01

    On average 80% of the radiopharmaceuticals used in Nuclear Medicine are labeled with 99 mTc due to its physical properties and easy attainment through of 99 Mo/ 99 mTc generators. The Directory of Radiopharmacy (DIRF) of IPEN-CNEN/SP developed a gel type chromatographic generator of MoZr with 99 Mo produced by 98 Mo(n,γ) 99 Mo reaction that occurs at the IEA-R1 Nuclear Reactor. The gel is composed of zirconium molybdate with elution volume of 12 mL with an activity of 11100 MBq (300 mCi) producing a radioactive concentration of 925 MBq (25 mCi)/mL. The fission generator gives a higher radioactive concentration around 1850 MBq (50 mCi)/mL. The aim of this work is to study a system of post-elution concentration of 99 mTc for the attainment of a high enough radioactive concentration to meet the demands of the market, with a proved quality. Two types of systems of post-elution concentration were developed: the single and the tandem. The most appropriate system for the gel generator of 99 Mo/ 99 mTc, being at the same time sterile and vacuum automated, was the tandem system using Dionex 2.5 cc/QMA cartridges. The gel generator is eluted with 10 mL of solution of 0.1% NaCl and the pertechnetate anion is retained in the QMA cartridge and further eluted with 4 mL of saline. The process takes no more than 30 minutes. The elution efficiency of the system of concentration was 90 %. At the beginning of 2009 a global crisis in the supply of 99 Mo took place making it necessary the development of alternative technologies for the production of 99 Mo/ 99 mTc generators using fission produced 99 Mo and the development of an appropriate method to extend the useful life of this generator. The results of this study showed that the same system developed for the post- concentration of the gel generator can be employed for the fission generator, using the tandem system, giving a concentration factor of 3 for the elution of 99 mTc. (author)

  15. The preparation of {sup 99m}Tc from {sup 99}Mo-{sup 99m}Tc using Poly-Zirconium Compound (PZC)

    Energy Technology Data Exchange (ETDEWEB)

    Laohawilai, S [Isotope Production Div., Office of Atomic Energy for Peace (Thailand)

    1998-10-01

    The process of for providing the {sup 99m}Tc-gel generator followed the protocol that received from Department of Radioisotopes, Tokai Research Establishment, JAERI. Sodium molybdate (molybdenum-99), pH 7 with concentration 20 mg/ml and activity nearly 1 mCi/ml was added into the adsorbent (PZC). The total activity of {sup 99}Mo was about 10 mCi and the heating time was varied from 3-18 hours at 70degC. The properties of the gel were studied for elution profile and elution efficiency. The molybdenum breakthrough in sodium pertechnetate (technetium-99m) was also performed. (author)

  16. A comparative study of 99Tcm-MDP, 99Tcm(V)-DMSA and 99Tcm-Citrate in diagnosis of bone malignant tumors and bone/joint infections

    International Nuclear Information System (INIS)

    Wu Zhaozhong; Wu Boyi; Lin Wei; Wei Xueli; Wu Hengfu; Fan Ziwen; Ouyang Zhi; Wu Changwei; Yuan Gewen

    2003-01-01

    The purpose of this study was to assess the diagnostic value of scans with 99 Tc m (V)-dimercaptosuccinic acid (DMSA) to localize bone metastases and to evaluate the capability to diagnose bone/joint infections with scans using 99 Tc m -Citrate. Eighteen patients referred to bone metastases and eighteen patients referred to bone and joint infection were studied. In all patients, a bone scan of 99 Tc m -MDP was obtained initially. Subsequently, comparative scans with 99 Tc m (V)-DMSA and 99 Tc m -Citrate were conducted successively. Pathologic finding and/or microbiological finding, X-ray CT and/or MRI, and/or clinical follow-up (until symptoms disappeared) were considered to be proof of the presence of bone metastases and bone/joint infection. All of the eighteen patients with diagnosed bone metastases and of the eighteen patients with diagnosed bone and joint infection had positive 99 Tc m -MDP scintigraphy. The fifteen patients with diagnosed bone metastases and the fifteen patients with diagnosed bone/joint infection had increased 99 Tc m (V) -DMSA accumulation at certain areas matched with those shown in 99 Tc m -MDP scans, and only one patient with diagnosed bone metastases and the fifteen patients with diagnosed bone and joint infection had increased 99 Tc m -Citrate accumulation at certain areas matched with those shown in 99 Tc m -MDP scans. 99 Tc m -MDP scans show 64 bone lesions in the bone metastases while 49 lesions by the 99 Tc m (V)-DMSA scans and only one lesion by the 99 Tc m -Citrate scans respectively. And 99 Tc m -MDP scans show 22 bone lesions in the bone and joint infection while 17 lesions by the 99 Tc m (V)-DMSA imaging and 16 lesions by the 99 Tc m -Citrate imaging respectively. For bone metastases diagnosis, the sensitivity of 99 Tc m (V)-DMSA imaging and 99 Tc m -Citrate imaging were 76.56% and 1.56%, respectively, and the specificity were only 22.73% and 27.27%, respectively. For bone and joint infection diagnosis, the sensitivity of two

  17. Generator of 99m Tc with MnO2 as support of 99 Mo

    International Nuclear Information System (INIS)

    Granados C, F.; Serrano G, J.

    2002-01-01

    The generator of 99m Tc with MnO 2 as support of 99 Mo was studied. By mean of static experiments the retention of 99 Mo in MnO 2 in function of the stirring time and of the p H value of the solution of 99 Mo. It was found that the 99 Mo presents 100% of retention in MnO 2 in the rank of p H 3-11 and the balance was reached before of 10 minutes. In dynamic conditions the retention of 99 Mo in MnO 2 at p H=5 was also higher: 99.72%. The generated 99m Tc can be separated from 99 Mo, adsorbed in MnO 2 packed in the column, using distilled water at p H=5 or NaCl solution at 0.9%. With saline solution the elution yields were greater than 80% and only an aliquot of 5 ml was necessary for obtaining this yield. The better results were obtained when the column was packed with 1 g of MnO 2 . The water and the saline solution were passed through of the column with a flux of 1.25 ml/min. (Author)

  18. Determination of Cyclam as Impurity in 99mTc-CTMP Using Radio electrophoresis Method

    International Nuclear Information System (INIS)

    Isti Daruwati; Misyetti; Maula Eka Sriyani; Teguh Hafiz AW

    2009-01-01

    Labelled compound of CTMP that are used for bone seeking radiopharmaceuticals must have to fulfill the standard requirements, such as have high radiochemical purity. CTMP compounds was in house synthesized from cyclam and formaldehyde in an acidic condition (conc. HCl) using Mannich methods. Impurities in CTMP product are the residue of cyclam, phosphoric acid, formaldehyde and hydrochloric acid. Formaldehyde and hydrochloride acid in the aqueous form is easily removed through the rinse process in the synthesis, while cyclam in the solid phase could be mix with CTMP. Therefore the impurities of cyclam in 99m Tc-CTMP must be determined. With nuclear technique, the determination of cyclam could be assessed simultaneously with labelled of CTMP with technetium-99m. Separation of 99m Tc-CTMP and 99m Tc-cyclam in solution was conducted with radio-electrophoresis method simultaneously. The radiochemical purity for both radiolabelled compound was determined by paper chromatography. The purity of radiolabelled 99m Tc-CTMP from cyclam was determined using electrophoresis method. The result show that the amount of cyclam in CTMP can be determined simultaneously using nuclear techniques with the labeling of 99m Tc-CTMP. Electrophoresis method can separated 99m Tc-cyclam, 99m Tc-CTMP, 99m TcO4 and 99m Tc-reduced with limit quantitation of cyclam until 0,4% w/w. (author)

  19. JENDL dosimetry file 99 (JENDL/D-99)

    International Nuclear Information System (INIS)

    Kobayashi, Katsuhei; Iwasaki, Shin

    2002-01-01

    The JENDL Dosimetry File 99 (JENDL/D-99), which is a revised version of the JENDL Dosimetry File 91 (JENDL/D-91), has been compiled and released for the determination of neutron flux and energy spectra. This work was undertaken to remove the inconsistency between the cross sections and their covariances in JENDL/D-91 since the covariances were mainly taken from IRDF-85 although the cross sections were based on JENDL-3. Dosimetry cross sections have been evaluated for 67 reactions on 47 nuclides together with covariances. The cross sections for 34 major reactions and their covariances were simultaneously generated, and the remaining 33 reaction data were mainly taken from JENDL/D-91. Latest measurements were taken into account in the evaluation. The resultant evaluated data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-6 format. In order to confirm the reliability of the evaluated data, several integral tests have been carried out: comparisons with average cross sections measured in fission neutron fields, fast/thermal reactor spectra, DT neutron fields and Li(d,n) neutron fields. It was found from the comparisons that the cross sections calculated from JENDL/D-99 are generally in good agreement with the measured data. The contents of JENDL/D-99 and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form in the Appendix. (author)

  20. Calculating the dim light melatonin onset: the impact of threshold and sampling rate.

    Science.gov (United States)

    Molina, Thomas A; Burgess, Helen J

    2011-10-01

    The dim light melatonin onset (DLMO) is the most reliable circadian phase marker in humans, but the cost of assaying samples is relatively high. Therefore, the authors examined differences between DLMOs calculated from hourly versus half-hourly sampling and differences between DLMOs calculated with two recommended thresholds (a fixed threshold of 3 pg/mL and a variable "3k" threshold equal to the mean plus two standard deviations of the first three low daytime points). The authors calculated these DLMOs from salivary dim light melatonin profiles collected from 122 individuals (64 women) at baseline. DLMOs derived from hourly sampling occurred on average only 6-8 min earlier than the DLMOs derived from half-hourly saliva sampling, and they were highly correlated with each other (r ≥ 0.89, p 30 min from the DLMO derived from half-hourly sampling. The 3 pg/mL threshold produced significantly less variable DLMOs than the 3k threshold. However, the 3k threshold was significantly lower than the 3 pg/mL threshold (p < .001). The DLMOs calculated with the 3k method were significantly earlier (by 22-24 min) than the DLMOs calculated with the 3 pg/mL threshold, regardless of sampling rate. These results suggest that in large research studies and clinical settings, the more affordable and practical option of hourly sampling is adequate for a reasonable estimate of circadian phase. Although the 3 pg/mL fixed threshold is less variable than the 3k threshold, it produces estimates of the DLMO that are further from the initial rise of melatonin.

  1. Status of {sup 99}Mo-{sup 99m}Tc production development by (n, {gamma}) reaction

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kunihiko; Kaminaga, Masanori; Ishihara, Masahiro; Kawamura, Hiroshi [Japan Atomic Energy Agency, Oarai Research and Development Center, Oarai, Ibaraki (Japan); Mutalib, Abdul [National Nuclear Energy Agency of Indonesia (BATAN), Tangerang (Indonesia); Chakrov, Petr [Institute of Nuclear Physics, National Nuclear Center of Republic of Kazakhstan (INP-NNC-RK), Almaty (Kazakhstan)

    2012-03-15

    Technetium-99m ({sup 99m}Tc) is one of the most commonly used radioisotopes in the field of nuclear medicine. As one of effective uses of the JMTR, JAEA has a plan to produce {sup 99}Mo by (n, {gamma}) method, a parent nuclide of {sup 99m}Tc. JAEA has performed R and D on production method of {sup 99}Mo-{sup 99m}Tc in JMTR cooperating with foreign organizations and relevant Japanese enterprises under the cooperation programs. In this paper, present status of R and D for production of {sup 99}Mo-{sup 99m}Tc in JMTR under international cooperation is introduced and constructions of the irradiation and PIE facilities at the JMTR site are also described. (author)

  2. Estimation of internal exposure to 99Mo in nuclear medicine patients

    International Nuclear Information System (INIS)

    Dantas, B.M.; Silva, C.O.A. da; Dantas, A.L.A.; Lucena, E.A.; Souza, W.O.

    2008-01-01

    99m Tc is the most widely used radionuclide in nuclear medicine. It is obtained by elution of 99 Mo- 99m Tc generators. Depending on the quality of the generator and its integrity, 99 Mo might be extracted from the column during the elution process, becoming a radionuclidic impurity in the 99m Tc eluate. This fact would impart an undesired dose to the patients submitted to diagnostic procedures using 99m Tc. The aims of this work are: to evaluate the incorporation of 99 Mo as a radionuclidic impurity using in vivo and in vitro techniques; to estimate the internal effective doses in nuclear medicine patients and; to provide additional information about the metabolic behavior of molybdenum in humans. A methodology based on in vivo measurements and urine sampling was developed to determine retention and excretion patterns of molybdenum in the human body. In vivo measurements were performed in IRD whole body counter using a NaI(Tl) 8”x4” scintillation detector. The detector is located inside a shielded room with internal dimensions of 2.5 x 2.5 x 2.65 meters. In vitro analysis was based on the collection of urine samples from the patients and was performed in IRD bioassay laboratory using a High Purity Germanium (HPGe) detection system. Four patients have been monitored by in vivo and in vitro measurements showing detectable activities of 99 Mo in whole body and urine samples. Bioassay results were interpreted by using AIDE software version 6. Estimated values of 99 Mo incorporation were compared to predicted values based on the standard metabolic model of molybdenum established by the International Commission of Radiological Protection (ICRP). Internal effective doses were estimated in the order of micro sieverts per examination. Based on the data obtained in this work it is suggested to implement a routine quality control program of radionuclidic impurity of 99 Mo in 99m Tc eluates to be conducted by radiopharmacy laboratories of nuclear medicine centers. (author)

  3. Can tumor uptake Tc-99m MDP ?

    International Nuclear Information System (INIS)

    Yand Shun, Fang; Yao, Ming; Zeng, Jun; Shi Zhen, Yu; Zhao Lan, Xiang; Dong Qiang, Gang

    2003-01-01

    To explore the mechanism of technetium-99m-methylene diphosphonate (MDP) uptake within tumor through analyze a distribution of Tc-99m MDP in mice bearing tumor cell lines. Methods: The uptake of Tc-99m MDP was analyzed in seven human tumor cell lines ( SPC-A1 adenocarcinoma of lung cancer, Bcap-37 Breast cancer, T-24 Bladder cancer, SKOV3 Ovary carcinoma, Hela-229 Cervical carcinoma, SCI-OS Osteosarcoma, SCI-375 Melanoma) and mouse Lewis lung cancer cell line. They were transplanted into athymic mice, SCID nude mice and C57BL/6 mice, respectively. Approximately 10(6) cells of each cell line were injected subcutaneously into a right chest of mouse. After 4 and 5 weeks, the Tc-99m MDP scintigraphy were determined 6 hours after tail vein injection of 74MBq in 0.05ml every mouse. Result: Biodistribution and tumor uptake MDP was different in the various cell types investigated. According to the Region Ratio program of Siemens Power Macintosh 9500 Computer System, region of interests (RIOs) placed on a small part of the tumor and horizontal copied to left background (T/B) and thoracic spine (T/N) of mice in Tc-99m MDP imaging. The average cpm/pixel ratios were calculated by standardized uptake measure (SUM) and determined the tumor-positive value (T/B) greater than or equal to 1.2. T/B of cell lines were sorted from higher to lower as follows: SCI-OS, Lewis, SKOV3, SCI-375, T-24, SPC-A1, Bcap-37, Hela-229. T/N: SCI-OS, SKOV3, T-24, SCI-375, Lewis, SPC-A1, Bcap-37, Hela-229. The biodistribution data of 99Tcm-MDP in SPC-A1 tumor-bearing BALB/c nude mice were given as ID/g and represent the means D (n=13) in 30 hours after injection of Tc-99m MDP. ID/g of major tissue were sorted from higher to lower as follows: thoracic spine, lumbar, ribs, kidneys, the center of tumor, the ulcer of tumor, the surrounding of tumor, lymph node, blood, lungs, heart, liver. Conclusions: Most of tumor can uptake Tc-99m MDP including human adenocarcinoma. The uptake rate in the center tissue of

  4. 99mTc-EDTA and 99mTc-DTPA complexes as hydrological tracers

    International Nuclear Information System (INIS)

    Dominguez, J.; Borroto, J.; Nazco, J.; Perez, E.; Gamboa, R.; Cruz, J.

    2002-01-01

    The [ 99m Tc-DTPA] 2- and [ 99m Tc-EDTA] 1- were evaluated as radiotracers for short time hydrological studies. Their complex stability after labelling with 9.25 GBq of 99m Tc, the behaviour against pH variations, from 5 to 9, in simulated solutions and in natural river waters and the sorption of these compounds on the river sediments, were tested in laboratory experiments. Finally field double tracing experiments were carried out for each of labelling complexes and Rhodamine WT. From recovery calculations not losses of the 99m Tc activity were observed. The shape of the RTD curves of the [ 99m Tc-DTPA] 2- and [ 99m Tc-EDTA] 1 were quite similar to the Rhodamine Wt ones. May be concluded that both complexes behaved conservatively on the studied environmental conditions. (author)

  5. Shifts in the relationship between motor unit recruitment thresholds versus derecruitment thresholds during fatigue.

    Science.gov (United States)

    Stock, Matt S; Mota, Jacob A

    2017-12-01

    Muscle fatigue is associated with diminished twitch force amplitude. We examined changes in the motor unit recruitment versus derecruitment threshold relationship during fatigue. Nine men (mean age = 26 years) performed repeated isometric contractions at 50% maximal voluntary contraction (MVC) knee extensor force until exhaustion. Surface electromyographic signals were detected from the vastus lateralis, and were decomposed into their constituent motor unit action potential trains. Motor unit recruitment and derecruitment thresholds and firing rates at recruitment and derecruitment were evaluated at the beginning, middle, and end of the protocol. On average, 15 motor units were studied per contraction. For the initial contraction, three subjects showed greater recruitment thresholds than derecruitment thresholds for all motor units. Five subjects showed greater recruitment thresholds than derecruitment thresholds for only low-threshold motor units at the beginning, with a mean cross-over of 31.6% MVC. As the muscle fatigued, many motor units were derecruited at progressively higher forces. In turn, decreased slopes and increased y-intercepts were observed. These shifts were complemented by increased firing rates at derecruitment relative to recruitment. As the vastus lateralis fatigued, the central nervous system's compensatory adjustments resulted in a shift of the regression line of the recruitment versus derecruitment threshold relationship. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  6. CEAMF study, volume 2 : cumulative effects indicators, thresholds, and case studies : final

    International Nuclear Information System (INIS)

    2003-03-01

    The four types of cumulative effects on the environment are: alteration, loss, and fragmentation of habitat; disturbance; barriers to movement; and direct and indirect mortality. Defining where and how human activities can be continued without irreversible net harm to the environment is part of cumulative effects management. Various land-use and habitat indicators were tested in the Blueberry and Sukunka study areas of British Columbia, to address the environmental effects associated with oil and gas development. As recommended, a tiered threshold approach was used to allow for flexibility in different land management regimes and ecological settings. Success will depend on defining acceptable change, threshold values, standard public database, standard processes to calculate indicator values using the database, and project-specific and cooperative management actions. A pilot study was suggested to test the candidate thresholds and implementation process. The two areas proposed for consideration were the Jedney Enhanced Resource Development Resource Management Zone in the Fort St. John Forest District, and the Etsho Enhanced Resource Development Resource Management Zone in the Fort Nelson Forest District. Both are of interest to the petroleum and forest sectors, and support the woodland caribou, a species which is extremely sensitive to cumulative effects of habitat fragmentation and disturbance. 117 refs., 11 tabs., 39 figs.

  7. Study of {sup 99m}Tc-DMSA biodistribution in experimental animals

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Thais O.M. de; Silva, Natanael G. da; Colturato, Maria T.; Felgueiras, Carlos F.; Mengatti, Jair; Fukumori, Neuza T.O.; Matsuda, Margareth M.N.; Araújo, Elaine B. de, E-mail: thais.castrom@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Radiofarmacia

    2017-11-01

    {sup 99m}Tc-DMSA, succimer ({sup 99m}Tc), is a radiopharmaceutical commonly used in nuclear medicine for renal function evaluation by imaging. In order to achieve adequate labeling of the product with good radiochemical yield and standardized biological distribution, the interval of 185 - 3700 MBq should be kept in a maximum volume of 3 mL for product labeling. Moreover, one should avoid exposing the reconstituted solution to oxygen and using the product after four hours post labeling. The aim of the study was to quantify and evaluate the influence of different DMSA complexes on biological distribution of the radiopharmaceutical in experimental animals, taking in account variations in the labeling parameters. Radiochemical purity was determined by paper and thin layer chromatography using both acetone/Whatman 3MM, 0.9% NaCl/TLC-SG and n-propanol/ H{sub 2}O/acetic acid (4:3:1 V/V/V)/TLC-SG systems respectively for quantification of {sup 99m}TcO{sub 4} - and {sup 99m}TcO{sub 2} plus some {sup 99m}Tc-DMSA complexes. The labeling activity did not significantly affect the extent of the main complex generation. The presence of oxygen and the concentration of {sup 99}Tc did not markedly change the percentage of the radiochemical impurities in the preparation. Radiochemical purity tests of the DMSA-{sup 99m}Tc based on IPEN-CNEN DMSA-TEC reagent and on another producer's reagent showed similar results. Although the routine method used by IPEN-CNEN to determine the radiochemical yield of {sup 99m}Tc-DMSA was not able to discriminate among {sup 99m}Tc-DMSA complexes, the renal uptake and the kidney to liver plus spleen uptake ratio in rats met the official compendia criteria for the radiopharmaceutical. (author)

  8. Study of "9"9"mTc-DMSA biodistribution in experimental animals

    International Nuclear Information System (INIS)

    Castro, Thais O.M. de; Silva, Natanael G. da; Colturato, Maria T.; Felgueiras, Carlos F.; Mengatti, Jair; Fukumori, Neuza T.O.; Matsuda, Margareth M.N.; Araújo, Elaine B. de

    2017-01-01

    "9"9"mTc-DMSA, succimer ("9"9"mTc), is a radiopharmaceutical commonly used in nuclear medicine for renal function evaluation by imaging. In order to achieve adequate labeling of the product with good radiochemical yield and standardized biological distribution, the interval of 185 - 3700 MBq should be kept in a maximum volume of 3 mL for product labeling. Moreover, one should avoid exposing the reconstituted solution to oxygen and using the product after four hours post labeling. The aim of the study was to quantify and evaluate the influence of different DMSA complexes on biological distribution of the radiopharmaceutical in experimental animals, taking in account variations in the labeling parameters. Radiochemical purity was determined by paper and thin layer chromatography using both acetone/Whatman 3MM, 0.9% NaCl/TLC-SG and n-propanol/ H_2O/acetic acid (4:3:1 V/V/V)/TLC-SG systems respectively for quantification of "9"9"mTcO_4 - and "9"9"mTcO_2 plus some "9"9"mTc-DMSA complexes. The labeling activity did not significantly affect the extent of the main complex generation. The presence of oxygen and the concentration of "9"9Tc did not markedly change the percentage of the radiochemical impurities in the preparation. Radiochemical purity tests of the DMSA-"9"9"mTc based on IPEN-CNEN DMSA-TEC reagent and on another producer's reagent showed similar results. Although the routine method used by IPEN-CNEN to determine the radiochemical yield of "9"9"mTc-DMSA was not able to discriminate among "9"9"mTc-DMSA complexes, the renal uptake and the kidney to liver plus spleen uptake ratio in rats met the official compendia criteria for the radiopharmaceutical. (author)

  9. Physico-chemical thresholds in the distribution of fish species among French lakes

    Directory of Open Access Journals (Sweden)

    Roubeix Vincent

    2017-01-01

    Full Text Available The management of lakes requires the definition of physico-chemical thresholds to be used for ecosystem preservation or restoration. According to the European Water Framework Directive, the limits between physico-chemical quality classes must be set consistently with biological quality elements. One way to do this consists in analyzing the response of aquatic communities to environmental gradients across monitoring sites and in identifying ecological community thresholds, i.e. zones in the gradients where the species turnover is the highest. In this study, fish data from 196 lakes in France were considered to derive ecological thresholds using the multivariate method of gradient forest. The analysis was performed on 25 species and 36 environmental parameters. The results revealed the highest importance of maximal water temperature in the distribution of fish species. Other important parameters included geographical factors, dissolved organic carbon concentration and water transparency, while nutrients appeared to have low influence. In spite of the diversity of species responses to the gradients, community thresholds were detected in the gradients of the most important physico-chemical parameters and of total phosphorus and nitrate concentrations as well. The thresholds identified in such macroecological study may highlight new patterns of species natural distribution and improve niche characterization. Moreover, when factors that may be influenced by human activities are involved, the thresholds could be used to set environmental standards for lake preservation.

  10. Optimization of the 99m Tc generator with hydrotalcite as support of 99 Mo

    International Nuclear Information System (INIS)

    Aranda O, N.

    2004-01-01

    In the last years, in the laboratories of the National Institute of Nuclear Investigations (ININ) its have been investigating to the hydrotalcite like a material of support of the 99 Mo with the purpose of developing a new technetium generator. During the development of the investigations it has been demonstrated that when putting in contact to the HTC with an aqueous solution that contains anions of any type, the HTC re hydrate and the structure is regenerated to laminate of the hydrotalcite. If the present anions in the solution are molybdate anions (MoO 4 2- ), these anions passed to be part of the structure of the hydrotalcite (HT-MoO 4 ). These anions can contain, in turn, 99 Mo in their composition ( 99 MoO 4 2- ) and equally they can pass to be part of the structure of the hydrotalcite forming the HT- 99 MoO 4 . When the HT- 99 MoO 4 is packed in a column, the 99m Tc that it takes place when decaying the 99 Mo radioactively can separate the column using aqueous solution of NaCl. This way, in previous studies (Serrano, 2000) it was found that the aqueous solution of NaCl to 0.5% it is the but appropriate for elutriate at the 99m Tc from the column the yield of the elution of the 99m Tc was since high (98%) in the first elution, and the radionuclide contamination caused by the presence of 99 Mo in the eluate it was low ( 4 2- for gram of HTC). These facts, standing out the high capacity of the HTC to retain molybdate ions, they drove from a direct way to investigate the optimization of the generator of 99m Tc, with hydrotalcite like support of the 99 Mo, using 99 Mo of low specific activity. This finishes radioactive material it can be obtained by the irradiation of the 98 Mo (in the chemical form of MoO 3 or (NH 4 ) 2 MoO 4 ), with a flow of thermal neutrons in the nuclear reactor TRIGA Mark lll that one has in the Nuclear Center N abor Carrillo Flores . The technetium generators with alumina like support of the 99 Mo use 99 Mo of high specific activity

  11. Evaluation of 99Mo/99mTc generator experiment using PZC material and irradiated natural molybdenum

    International Nuclear Information System (INIS)

    Khongpetch, P.; Chingjit, S.; Dangprasert, M.; Rangsawai, W.; Virawat, N.

    2006-01-01

    Technetium-99m ( 99m Tc) is the most widely used radioisotope in nuclear medicine, accounting for more than 80% of all diagnostic nuclear medicine procedure. 99m Tc is almost exclusively produced from the decay of its parent molybdenum-99 ( 99 Mo). The present sources of 99 Mo are research reactors by using the (n, γ) nuclear reaction with natural molybdenum, resulting in inexpensive but low specific activity 99 Mo, or by neutron-induced fission of uranium-235, which result in expensive but high specific activity 99 Mo. The technology requirement for processing of 99 Mo from the (n, γ) 'activation method' is rather simple, and is within the reach of most developing countries operating research reactors. In the fission method' the technological and infrastructure requirements are some complex, and possibly can be sustained only by countries with advanced nuclear technology. To overcome these difficulties, Japan Atomic Energy Research Institute (JAERI) and KAKEN company have developed alternative technology for 99 Mo/ 99m Tc generator by using a molybdenum absorbent called Poly Zirconium compound (PZC) and irradiated natural molybdenum. The paper describes experiments for evaluation the performance of PZC as a column packing material for 99 Mo/ 99m Tc generator from (n, γ) 99 Mo. (author)

  12. 76 FR 70414 - National Fire Protection Association (NFPA) Proposes To Revise Codes and Standards

    Science.gov (United States)

    2011-11-14

    ... Commercial Cooking Operations. NFPA 99--2012 Health Care Facilities Code 6/22/2012 NFPA 99B--2010 Standard... Explosion Investigations..... 1/4/2012 NFPA 1005--2007 Standard for Professional Qualifications for 1/4/2012 Marine Fire Fighting for Land-Based Fire Fighters. NFPA 1021--2009 Standard for Fire Officer Professional...

  13. Determination of Tc-99 in radioactive wastes; Determinacion de Tc-99 en desechos radiactivos

    Energy Technology Data Exchange (ETDEWEB)

    Rivera S, A. A.

    2015-07-01

    Tc-99 is a fission product and one of the most important radionuclides from the view point of safety assessment for the disposal of radioactive waste because of its long half-life (2.1 x 10{sup 5} years) and high mobility in soil-water systems, if this is released into the environment in significant quantities can concentrate on plants and animals. Tc-99 is a pure beta emitter with a maximum energy of 292 KeV, so their quantification imposes destructive methods to be analyzed by liquid scintillation. Therefore the quantification of Tc-99 in ion exchange resins requires of the mineralization of these and separation of Tc-99 of other radioisotopes present in the resin. Therefore the object of this thesis is to develop a quantification method of Tc-99 content in spent exchange resins. So in order to track the behavior of technetium during digestion exchange resins and radiochemical separation, given its high volatility, in this work the {sup 99m}Tc is used. To determine the degree of mineralization of the resins, an analysis was performed by chromatography. Subsequently the method used to determine the percentage of {sup 99m}Tc aerosolized during mineralization of resin is described. After the method for the radiochemical separation of {sup 99m}Tc is presented by liquid-liquid extraction using crown ether as extractant; for this testing was performed by varying the molarity of the extractant, the ratio of solvent extractant, type of digestion of the resin and the presence of Sr-85, in order to study the behavior of {sup 99m}Tc in the presence of this radioisotope. Finally, a track beta spectra of a sample of {sup 99m}Tc eluted from a generator {sup 99}Mo/{sup 99m}Tc function of time was performed. (Author)

  14. On the need for a time- and location-dependent estimation of the NDSI threshold value for reducing existing uncertainties in snow cover maps at different scales

    Science.gov (United States)

    Härer, Stefan; Bernhardt, Matthias; Siebers, Matthias; Schulz, Karsten

    2018-05-01

    Knowledge of current snow cover extent is essential for characterizing energy and moisture fluxes at the Earth's surface. The snow-covered area (SCA) is often estimated by using optical satellite information in combination with the normalized-difference snow index (NDSI). The NDSI thereby uses a threshold for the definition if a satellite pixel is assumed to be snow covered or snow free. The spatiotemporal representativeness of the standard threshold of 0.4 is however questionable at the local scale. Here, we use local snow cover maps derived from ground-based photography to continuously calibrate the NDSI threshold values (NDSIthr) of Landsat satellite images at two European mountain sites of the period from 2010 to 2015. The Research Catchment Zugspitzplatt (RCZ, Germany) and Vernagtferner area (VF, Austria) are both located within a single Landsat scene. Nevertheless, the long-term analysis of the NDSIthr demonstrated that the NDSIthr at these sites are not correlated (r = 0.17) and different than the standard threshold of 0.4. For further comparison, a dynamic and locally optimized NDSI threshold was used as well as another locally optimized literature threshold value (0.7). It was shown that large uncertainties in the prediction of the SCA of up to 24.1 % exist in satellite snow cover maps in cases where the standard threshold of 0.4 is used, but a newly developed calibrated quadratic polynomial model which accounts for seasonal threshold dynamics can reduce this error. The model minimizes the SCA uncertainties at the calibration site VF by 50 % in the evaluation period and was also able to improve the results at RCZ in a significant way. Additionally, a scaling experiment shows that the positive effect of a locally adapted threshold diminishes using a pixel size of 500 m or larger, underlining the general applicability of the standard threshold at larger scales.

  15. Radiolabeling, quality control and kit formulation of a new 99mTc-labeled antibiotic. 99mTc-doxycycline hyclate

    International Nuclear Information System (INIS)

    Derya Ilem-Oezdemir; Makbule Asikoglu; Hayal Oezkilic

    2013-01-01

    Since radiolabeled antibiotics specifically bind to the bacterial components they are promising radiopharmaceuticals for the precise diagnosis and detection of infectious lesions. Doxycycline hyclate (DOX) was chosen to investigate as a new radiolabeled antibacterial agent since its bacteriostatic activity against a wide variety of microorganisms. The aim of the present study is to develop simple and easy formulation of DOX with 99m Tc ready to use kit. 99m Tc-DOX was developed and standardized under varying conditions of reducing and antioxidant agent concentration, pH, radioactivity dose and reducing agent type. Labeling studies were performed by changing the selected parameters one by one and optimum labeling conditions were determined. After observing the conditions for maximum labeling efficiency and stability, lyophilized freeze dry kits were prepared accordingly. Radiochemical purity was determined with RTLC and RHPLC which was found more than >95 %. Two different freeze dry kits were formulated with optimum labeling conditions. The improved kits were found stable up to 6 months. (author)

  16. Dual-phase 99mTc-MIBI scintigraphy with delayed neck and thorax SPECT/CT and bone scintigraphy in patients with primary hyperparathyroidism. Correlation with clinical or pathological variables

    International Nuclear Information System (INIS)

    Qiu, Zhongling; Shen, Chentian; Zhu, Ruisen; Luo, Quanyong; Wu, Bo

    2014-01-01

    The purpose of this study was to assess the relationship between 99m Tc-MIBI and 99m Tc-MDP bone scintigraphy and clinical or pathological variables, including preoperative serum PTH levels and tumor diameter, in patients with newly diagnosed PHPT. Dual phase 99m Tc-MIBI planar scintigraphy was performed in 244 patients with PHPT. Of these patients, 155 underwent 99m Tc-MDP bone scintigraphy to detect bone changes before parathyroidectomy. Factors influencing 99m Tc-MIBI scintigraphy and 99m Tc-MDP bone scintigraphy detection rate were assessed using univariate and multivariate logistic regression analysis; optimal cutoff values for predicting positive 99m Tc-MIBI and 99m Tc-MDP bone scintigraphy were evaluated using ROC analysis. Among 244 patients, 174 (71.31%) patients with 181 foci had a positive 99m Tc-MIBI planar scintigraphy; delayed neck and thorax SPECT/CT could identify and locate the 99m Tc-MIBI lesions but could not find more lesions than planar scintigraphy. 70 (28.69%) patients had a negative 99m Tc-MIBI planar scintigraphy. Tumor diameter, serum PTH level and symptoms were statistically significant predictive factors in predicting positive 9m Tc-MIBI scintigraphy both univariate and multivariate logistic regression analyses. The optimal thresholds for tumor diameter and serum PTH by ROC analysis were 1.03 cm and 127.60 ng/L, respectively. Among 155 patients with bone scintigraphy, 99m Tc-MDP bone scintigraphy showed positive finding in 80 (51.61%) patients and negative finding in 75 patients. Univariate logistic regression analysis showed that patient age, sex, tumor diameter and PTH level (≥150 ng/L) were statistically significant in predicting positive 99m Tc-MDP bone scintigraphy. Multivariate logistic regression analysis showed both tumor diameter and PTH ≥150 ng/L were statistically significant in predicting positive 99m Tc-MDP bone scintigraphy. The optimal thresholds for tumor diameter and serum PTH by ROC analysis were 1.96 cm and 163

  17. Technetium-99 levels in pertechnetate solutions from (n,γ) and (n,f) molybdenum-99 generators

    International Nuclear Information System (INIS)

    Moore, P.W.

    1983-04-01

    There is increasing evidence that, in some radiopharmaceutical kits, Tc-99 has an adverse effect on the imaging and labelling performance of Tc-99m. For example, labelling efficiency with red blood cells can be affected when 99/99m ratios exceed about 4:1. The 99/99m ratio in a target is about 13.5:1 after a seven-day irradiation in a nuclear reactor. The ratio increases slightly during the time needed for processing. With the chromatographic generators used in hospitals, up to 90 hours may elapse between the final wash stage of manufacture and the first elution, during which time, 99/99m ratios can increase to about 90:1. If elution efficiencies are high and the time between elutions is between 12 and 24 hours, ratios in the generator, hence in the eluates, may actually increase with each elution. In the case of ready-to-inject pertechnetate solutions, the critical time at which 99/99m ratios increase rapidly is the time between elution and use. If production conditions are poor, ratios may increase to more than 600:1 by the time of use. With better conditions and production schedules Tc-99 levels at the time of use are comparable to those from chromatographic generators

  18. Threshold factorization redux

    Science.gov (United States)

    Chay, Junegone; Kim, Chul

    2018-05-01

    We reanalyze the factorization theorems for the Drell-Yan process and for deep inelastic scattering near threshold, as constructed in the framework of the soft-collinear effective theory (SCET), from a new, consistent perspective. In order to formulate the factorization near threshold in SCET, we should include an additional degree of freedom with small energy, collinear to the beam direction. The corresponding collinear-soft mode is included to describe the parton distribution function (PDF) near threshold. The soft function is modified by subtracting the contribution of the collinear-soft modes in order to avoid double counting on the overlap region. As a result, the proper soft function becomes infrared finite, and all the factorized parts are free of rapidity divergence. Furthermore, the separation of the relevant scales in each factorized part becomes manifest. We apply the same idea to the dihadron production in e+e- annihilation near threshold, and show that the resultant soft function is also free of infrared and rapidity divergences.

  19. Scintigraphic findings on 99mTc-MDP, 99mTc-sestamibi and 99mTc-HMPAO images in Gaucher's disease

    International Nuclear Information System (INIS)

    Mariani, G.; Molea, N.; La Civita, L.; Porciello, G.; Lazzeri, E.; Ferri, C.

    1996-01-01

    We report here on the use of the lipophilic cationic complex technetium-99m sestamibi ( 99m Tc-MIBI), employed as an indicator of increased cellular density and metabolic activity, to evaluate Gaucher cell infiltrates in the bone marrow; 99m Tc-hexametazime ( 99m Tc-HMPAO) was also employed, as a pure indicator of lipidic infiltration in the bone marrow. A 67-year-old patient with known type 1 Gaucher's disease presented with a painful left hip and knee and difficulty in gait subsequent to traumatic fracture of the left femoral neck that had required implant of a fixation screw-plaque. Bone scan with 99m Tc-methylene diphosphonate revealed reduced uptake at the distal metaphyseal-epiphyseal femoral region. In addition, whole-body maps and spot-view acquisitions of the thighs and legs were recorded at both 30 min and 2.5 h after the injection of 99m Tc-MIBI: the scintigraphic pattern clearly showed increased uptake at several sites involved by Gaucher deposits in the bone marrow (both knees, with variable intensity in different areas), matching the bone changes detected by conventional x-ray. The target to non-target ratios slowly decreased with time, from an average value of 2.25 in the early scan to an average value of 2 in the delayed scan. The lipid-soluble agent 99m Tc-HMPAO exhibited a superimposable scintigraphic pattern of accumulation at the involved sites, though with lower target to non-target ratios (1.27-1.48). The results obtained in this patient suggest a potential role of 99m Tc-MIBI in the scintigraphic evaluation of Gaucher's lipid deposits in the bone marrow. If the results are confirmed in other patients, this radiopharmaceutical would offer clear advantages over 133 Xe because of its wider availability and greater practicality (i.v. administration of 99m Tc-MIBI versus inhalation of 133 Xe, and use of a single gamma camera instead of two as with 133 Xe). (orig.). With 3 figs

  20. Reliability and responsiveness of algometry for measuring pressure pain threshold in patients with knee osteoarthritis.

    Science.gov (United States)

    Mutlu, Ebru Kaya; Ozdincler, Arzu Razak

    2015-06-01

    [Purpose] This study aimed to establish the intrarater reliability and responsiveness of a clinically available algometer in patients with knee osteoarthritis as well as to determine the minimum-detectable-change and standard error of measurement of testing to facilitate clinical interpretation of temporal changes. [Subjects] Seventy-three patients with knee osteoarthritis were included. [Methods] Pressure pain threshold measured by algometry was evaluated 3 times at 2-min intervals over 2 clinically relevant sites-mediolateral to the medial femoral tubercle (distal) and lateral to the medial malleolus (local)-on the same day. Intrarater reliability was estimated by intraclass correlation coefficients. The minimum-detectable-change and standard error of measurement were calculated. As a measure of responsiveness, the effect size was calculated for the results at baseline and after treatment. [Results] The intrarater reliability was almost perfect (intraclass correlation coefficient = 0.93-0.97). The standard error of measurement and minimum-detectable-change were 0.70-0.66 and 1.62-1.53, respectively. The pressure pain threshold over the distal site was inadequately responsive in knee osteoarthritis, but the local site was responsive. The effect size was 0.70. [Conclusion] Algometry is reliable and responsive to assess measures of pressure pain threshold for evaluating pain patients with knee osteoarthritis.

  1. Localization diagnosis of hyperfunctional parathyroid gland using 99Tcm-MIBI and 99TcmO4- imaging

    International Nuclear Information System (INIS)

    Zhang Fenru; Deng Huixing; Duan Xiaoyi; Xue Jianjun; Gao Rui

    2010-01-01

    Objective: To study the localization diagnosis value of nuclide imaging by 99 Tc m -MIBI double phase parathyroid combined with 99 Tc m O 4 - thyroid imaging in patients with hyperparathyroidism (HPT). Methods: Patients with primary HPT were 36 cases. Control groups were 10 cases with thyroid disease. Early phase imaging was performed in 15 minute after injecting imaging agent 99 Tc m -MIBI. Delay phase imaging was performed in 2 hours. 36 HPT patients and 10 cases control groups were also performed 99 Tc m O 4 - thyroid imaging 24 hours later. The two kinds of imaging were compared with each other, were analyzed, and were underwent imaging subtracted by eyes and imaging results judgment. Results: In 36 cases of HPT patients, 34 cases showed positive result imaging with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. 2 cases showed false negative result. Positive rate was 94.44 % with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. The positive result imaging showed abnormal increased uptake of 99 Tc m -MIBI. In 36 cases of HPT patients, 12 cases showed positive result with single 99 Tc m -MIBI imaging. 4 cases showed false negative imaging. 20 cases showed ambiguous positive results. Positive rate was 88.89% (55.56% was ambiguous positive results) with single 99 Tc m -MIBI imaging. In 10 cases control groups, 3 cases showed false positive results with single 99 Tc m -MIBI imaging. 1 case showed ambiguous false positive results. No case showed false positive result with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. Conclusion: 99 Tc m -MIBI parathyroid double phase imaging combined with 99 Tc m O 4 - thyroid imaging have important value for diagnoses and localization of hyperparathyroidism. 99 Tc m -MIBI/ 99 Tc m O 4 - imaging have higher positive rate and higher specificity than single 99 Tc m -MIBI imaging for diagnoses and localization of hyperfunction parathyroid gland. (authors)

  2. Optimization of the {sup 99m} Tc generator with hydrotalcite as support of {sup 99} Mo; Optimizacion del generador de {sup 99m} Tc con hidrotalcita como soporte del {sup 99} Mo

    Energy Technology Data Exchange (ETDEWEB)

    Aranda O, N

    2004-07-01

    In the last years, in the laboratories of the National Institute of Nuclear Investigations (ININ) its have been investigating to the hydrotalcite like a material of support of the {sup 99} Mo with the purpose of developing a new technetium generator. During the development of the investigations it has been demonstrated that when putting in contact to the HTC with an aqueous solution that contains anions of any type, the HTC re hydrate and the structure is regenerated to laminate of the hydrotalcite. If the present anions in the solution are molybdate anions (MoO{sub 4}{sup 2-}), these anions passed to be part of the structure of the hydrotalcite (HT-MoO{sub 4}). These anions can contain, in turn, {sup 99} Mo in their composition ({sup 99}MoO{sub 4}{sup 2-}) and equally they can pass to be part of the structure of the hydrotalcite forming the HT-{sup 99}MoO{sub 4}. When the HT-{sup 99}MoO{sub 4} is packed in a column, the {sup 99m}Tc that it takes place when decaying the {sup 99}Mo radioactively can separate the column using aqueous solution of NaCl. This way, in previous studies (Serrano, 2000) it was found that the aqueous solution of NaCl to 0.5% it is the but appropriate for elutriate at the {sup 99m}Tc from the column the yield of the elution of the {sup 99m}Tc was since high (98%) in the first elution, and the radionuclide contamination caused by the presence of {sup 99}Mo in the eluate it was low (<0.01%). In this investigation it was also found that the HTC has a high capacity to retain molybdate ions (255.1 mg of ions MoO{sub 4}{sup 2-} for gram of HTC). These facts, standing out the high capacity of the HTC to retain molybdate ions, they drove from a direct way to investigate the optimization of the generator of {sup 99m}Tc, with hydrotalcite like support of the {sup 99}Mo, using {sup 99}Mo of low specific activity. This finishes radioactive material it can be obtained by the irradiation of the {sup 98}Mo (in the chemical form of MoO{sub 3} or (NH{sub 4

  3. Evaluation of the absorbed dose to the kidneys due to Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3) and Tc{sup 99m} (Dmsa); Evaluacion de la dosis absorbida en los rinones debido al Tc{sup 99m} (DTPA) / Tc{sup 99m} (MAG3) y Tc{sup 99m} (DMSA)

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez A, M.; Murillo C, F.; Castillo D, C.; Rocha J, J.; Sifuentes D, Y.; Sanchez S, P. [Universidad Nacional de Trujillo, Av. Juan Pablo II s/n, Trujillo (Peru); Idrogo C, J.; Marquez P, F., E-mail: marvva@hotmail.com [Instituto Nacional de Enfermedades Neoplasicas, Av. Angamos 2520, Lima (Peru)

    2015-10-15

    The absorbed dose in the kidneys of adult patients has been assessed using the biokinetics of radiopharmaceuticals containing Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3) or Tc{sup 99m} (Dmsa).The absorbed dose was calculated using the formalism MIRD and the Cristy-Eckerman representation for the kidneys. The absorbed dose to the kidneys due to Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3), are given by 0.00466 mGy.MBq{sup -1} / 0.00339 mGy.MBq{sup -1}. Approximately 21.2% of the absorbed dose is due to the bladder (content) and the remaining tissue, included in biokinetics of Tc{sup 99m} (DTPA) / Tc{sup 99m} (Mag3). The absorbed dose to the kidneys due to Tc{sup 99m} (Dmsa) is 0.17881 mGy.MBq{sup -1}. Here, 1.7% of the absorbed dose is due to the bladder, spleen, liver and the remaining tissue, included in biokinetics of Tc{sup 99m} (Dmsa). (Author)

  4. Detection thresholds of macaque otolith afferents.

    Science.gov (United States)

    Yu, Xiong-Jie; Dickman, J David; Angelaki, Dora E

    2012-06-13

    The vestibular system is our sixth sense and is important for spatial perception functions, yet the sensory detection and discrimination properties of vestibular neurons remain relatively unexplored. Here we have used signal detection theory to measure detection thresholds of otolith afferents using 1 Hz linear accelerations delivered along three cardinal axes. Direction detection thresholds were measured by comparing mean firing rates centered on response peak and trough (full-cycle thresholds) or by comparing peak/trough firing rates with spontaneous activity (half-cycle thresholds). Thresholds were similar for utricular and saccular afferents, as well as for lateral, fore/aft, and vertical motion directions. When computed along the preferred direction, full-cycle direction detection thresholds were 7.54 and 3.01 cm/s(2) for regular and irregular firing otolith afferents, respectively. Half-cycle thresholds were approximately double, with excitatory thresholds being half as large as inhibitory thresholds. The variability in threshold among afferents was directly related to neuronal gain and did not depend on spike count variance. The exact threshold values depended on both the time window used for spike count analysis and the filtering method used to calculate mean firing rate, although differences between regular and irregular afferent thresholds were independent of analysis parameters. The fact that minimum thresholds measured in macaque otolith afferents are of the same order of magnitude as human behavioral thresholds suggests that the vestibular periphery might determine the limit on our ability to detect or discriminate small differences in head movement, with little noise added during downstream processing.

  5. Impact of PET reconstruction algorithm and threshold on dose painting of non-small cell lung cancer

    International Nuclear Information System (INIS)

    Knudtsen, Ingerid Skjei; Elmpt, Wouter van; Öllers, Michel; Malinen, Eirik

    2014-01-01

    Purpose: In the current work, we investigate the impact of PET reconstruction methods (RMs) and threshold on two types of dose painting (DP) prescription strategies for non-small cell lung cancer (NSCLC). Materials and methods: Sixteen patients with NSCLC underwent an 18F-FDG-PET/CT examination prior to radiotherapy. Six different RMs were used. For both a dose painting by contours (DPBC) and a dose painting by numbers (DPBN) strategy, the prescribed radiation dose within the gross tumor volume (GTV) was mapped according to the spatial distribution of standardized uptake values (SUVs). SUV max and SUV peak were used for volume thresholding in DPBC and a linear SUV-dose scaling approach was used for DPBN. Deviations from the dose prescription as determined by the standard RM was scored by a quality factor (QF). Results: For DPBC, the mean difference in thresholded boost volume between RMs was typically within 10%. The difference in dose prescription was systematically lower for thresholding based on SUV peak (largest mean QF 2.8 ± 2.0%) compared to SUV max (largest mean QF 3.6 ± 3.0%). For DPBN, the resulting dose prescriptions were less dependent on RM and threshold; the largest mean QFs were 1.3 ± 0.3% both for SUV max and SUV peak . Conclusions: PET reconstruction algorithms will both influence DPBC and DPBN, although the impact is smaller for DPBN. For some patients, the resulting variations in dose prescriptions may result in clinically different dose distributions. SUV peak is a more robust thresholding parameter than SUV max

  6. {sup 99m}Tc-Annexin A5 quantification of apoptotic tumor response: a systematic review and meta-analysis of clinical imaging trials

    Energy Technology Data Exchange (ETDEWEB)

    Belhocine, Tarik Z. [Western University, Biomedical Imaging Research Centre (BIRC), London, Ontario (Canada); Blankenberg, Francis G. [Lucile Salter Packard Children' s Hospital, Stanford, Division of Pediatric Radiology, Department of Radiology, Palo Alto, CA (United States); Kartachova, Marina S. [Medical Center Alkmaar, Department of Nuclear Medicine, Alkmaar (Netherlands); Stitt, Larry W. [LW Stitt Statistical Services, London, Ontario (Canada); Vanderheyden, Jean-Luc [JLVMI Consulting LLC, Waukesha, WI (United States); Hoebers, Frank J.P. [Maastricht University Medical Centre, Department of Radiation Oncology (MAASTRO Clinic), GROW School for Oncology and Developmental Biology, Maastricht (Netherlands); Wiele, Christophe van de [University Hospital Ghent, Department of Nuclear Medicine and Radiology, Ghent (Belgium)

    2015-12-15

    , an increase of ≥25 % in uptake following treatment was considered a significant threshold for an apoptotic tumor response (partial response, complete response). In three other phase I/II clinical trials, increases of ≥28 %, ≥42 % and ≥47 % in uptake following treatment were found to be the mean cut-off levels in responders. In a phase II/III multicenter clinical trial, an increase of ≥23 % in uptake following treatment was found to be the minimum cut-off level for a tumor response. In one clinical trial, no significant difference in {sup 99m}Tc-annexin A5 uptake in terms of %ID was found in healthy tissues after chemotherapy compared to baseline. In two other clinical trials, intraobserver and interobserver measurements of {sup 99m}Tc-annexin A5 tumor uptake were found to be reproducible (mean difference <5 %, kappa = 0.90 and 0.82, respectively) and to be highly correlated with treatment outcome (Spearman r = 0.99, p < 0.0001). The meta-analysis demonstrated a pooled positive PPV of 100 % (95 % CI 92 - 100 %) and a pooled NPV of 70 % (95 % CI 55 - 82 %) for prediction of a tumor response after the first course of chemotherapy and/or radiotherapy in terms of ΔU%. In a symmetric sROC analysis, the AUC was 0.919 and the Q* index was 85.21 %. Quantitative {sup 99m}Tc-annexin A5 imaging has been investigated in clinical trials for the assessment of apoptotic tumor responses. This meta-analysis showed a high pooled PPV and a moderate pooled NPV with ΔU cut-off values ranging between 20 % and 30 %. Standardization of quantification and harmonization of results are required for high-quality clinical research. A standardized uptake value score (SUV, ΔSUV) using quantitative SPECT/CT imaging may be a promising approach to the simple, reproducible and semiquantitative assessment of apoptotic tumor changes. (orig.)

  7. Rechargeable sup(99)MO/sup(99m)TC generator system

    International Nuclear Information System (INIS)

    Thornton, A.K.; Cerone, F.E.

    1980-01-01

    A rechargeable radioisotope generator system is described in which the transfer of the parent isotope, molybdenum 99, can be affected safely and easily. Part of the system consists of a shielded shipping vial for the parent isotope. The generator consists of an alumina column upon which molybdenum 99 may be adsorbed and from which technetium 99m may be eluted. The generator is shipped as a cold package to the user and is charged as needed. A transfer mechanism is incorporated in the shipping shield, which allows the septum of the vial to be pierced and the contents to be transferred to the generator essentially automatically. (LL)

  8. Reduced modular symmetries of threshold corrections and gauge coupling unification

    Energy Technology Data Exchange (ETDEWEB)

    Bailin, David; Love, Alex [Department of Physics & Astronomy, University of Sussex,Brighton, BN1 9QH (United Kingdom)

    2015-04-01

    We revisit the question of gauge coupling unification at the string scale in orbifold compactifications of the heterotic string for the supersymmetric Standard Model. In the presence of discrete Wilson lines threshold corrections with modular symmetry that is a subgroup of the full modular group arise. We find that reduced modular symmetries not previously reported are possible. We conjecture that the effects of such threshold corrections can be simulated using sums of terms built from Dedekind eta functions to obtain the appropriate modular symmetry. For the cases of the ℤ{sub 8}-I orbifold and the ℤ{sub 3}×ℤ{sub 6} orbifold it is easily possible to obtain gauge coupling unification at the “observed” scale with Kähler moduli T of approximately one.

  9. Role of scintigammagraphy with 99mTc-Gluthatione and 99mTc-MIBI in the evaluation and staging of lymphoma

    International Nuclear Information System (INIS)

    Pena Quian, Yamile; Perera Pintado, Alejandro; Coca Perez, Marco A.; Batista Cuellar, Juan F.; Prats Capote, Anais; Sanchez Mendoza, Elvia; Sosa, Adriana; Mesa Cuervo, Jose R.; Hernandez Ramirez, Porfirio

    2004-01-01

    Full text: The aim of this study was to assess the utility of scintigammagraphy using 99mTc-MIBI and 99mTc-Gluthatione for the evaluation and staging of patients with lymphomas. We studied thirty patients (age range 16-66 years) of Hodgkin's disease (HD) and non-Hodgkin's lymphoma (NHL). A control group (CG) of 8 patients with negative histological results was also studied. The patients were divided in three groups; HD group: thirteen patients (7 males and 6 females); NHL: seventeen patients (10 males and 7 females); CG: eight patients (2 males and 6 females). Scintigammagraphy studies were performed 20 min and 2 h after intravenous administration of 925-1110 MBq of 99mTc-MIBI or 99mTc-Gluthatione (GSH) using a gamma camera (Sophy DS-7, Sopha Medical System, France) equipped with low energy all purpose parallel hole collimator. Anterior and posterior images of thorax, abdomen and pelvis in 128x128 pixels matrix each for 1 million counts per view were acquired. A 20% window centered on the 140 keV was used for all acquisitions. All images were processed and analysed on a workstation (Power Vision, SMV, Canada) and interpreted by three qualified and experienced nuclear medicine specialist. The final diagnosis was reached by consensus. The images with a focal abnormal intense uptake were considered positive. Images showing diffuse bilateral and symmetrical uptake, bilateral lung uptake and intestinal uptake were considered negative. The overall sensitivity, specificity and accuracy of results for both radiopharmaceuticals were calculated using the histological findings, x-ray, ultrasound and CT scanning as confirmation criterion as gold standard. The nodular sclerosis was the most frequent type in HD group. In this group twelve patients were positive with 99mTc-MIBI scintigammagraphy while one was negative (nodular sclerosis, grade II). Scintigammagraphy with 99mTc-GSH was positive in all patients in HD group. However, scintigammagraphy with both radiopharmaceuticals

  10. The preparation and biodistribution of a new 99Tcm-nitrito complex 99TcmN-MIBI

    International Nuclear Information System (INIS)

    Zhang Xianzhong; Wang Xuebin; Zhang Junbo

    1997-01-01

    The technetium-99m nitrito intermediate is synthesized by using SnCl 2 ·2H 2 O as reductant, and the complex 99 Tc m N-MIBI is obtained through ligand exchange reaction. The labelling yield of 99 Tc m N-MIBI is over 95% by TLC. The conditions of preparing 99 Tc m N-MIBI are optimized. Results of stability and partition coefficient of 99 Tc m N-MIBI indicate that the complex is lipophilic and stable over 10 h at room temperature. The biodistribution of 99 Tc m N-MIBI in mice shows high myocardium uptake, and rather rapid clearance. For 5-min post-injection the heart-to-blood, heart-to-lung and heart-to-liver ratios are 3.18, 1.72 and 1.42, respectively. The new complex may be suitable for instant myocardial imaging. 99 Tc m N-MIBI has significant different biodistribution characteristics from 99 Tc m -MIBI. Based on these promising properties, 99 Tc m N-MIBI should be a new potential myocardial perfusion imaging agent

  11. Threshold guidance update

    International Nuclear Information System (INIS)

    Wickham, L.E.

    1986-01-01

    The Department of Energy (DOE) is developing the concept of threshold quantities for use in determining which waste materials must be handled as radioactive waste and which may be disposed of as nonradioactive waste at its sites. Waste above this concentration level would be managed as radioactive or mixed waste (if hazardous chemicals are present); waste below this level would be handled as sanitary waste. Last years' activities (1984) included the development of a threshold guidance dose, the development of threshold concentrations corresponding to the guidance dose, the development of supporting documentation, review by a technical peer review committee, and review by the DOE community. As a result of the comments, areas have been identified for more extensive analysis, including an alternative basis for selection of the guidance dose and the development of quality assurance guidelines. Development of quality assurance guidelines will provide a reasonable basis for determining that a given waste stream qualifies as a threshold waste stream and can then be the basis for a more extensive cost-benefit analysis. The threshold guidance and supporting documentation will be revised, based on the comments received. The revised documents will be provided to DOE by early November. DOE-HQ has indicated that the revised documents will be available for review by DOE field offices and their contractors

  12. The use of 99Mo/99mTc generators in the analysis of low levels of 99Tc in environmental samples by radiochemical methods

    International Nuclear Information System (INIS)

    Dowdall, M.; Selnaes, Oe.G.; Lind, B.; Gwynn, J.P.

    2010-01-01

    The analysis of low levels of 99 Tc in environmental samples presents special challenges, particularly with respect to the selection of an appropriate and practicable chemical yield tracer. Of all the tracers available, 99m Tc eluted from 99 Mo/ 99m Tc generators appears to be the most practicable in terms of availability, ease of use and cost. These factors have led to an increase in the use of such generators for the provision of 99m Tc as yield tracer for 99 Tc. For the analysis of low levels ( 3 or kg) of 99 Tc in environmental samples, consideration must be given to the radiochemical purity of the tracer solution with respect to contamination with both 99 Tc and other radionuclides. Due to the variable nature of the extent of the interference from tracer solution to tracer solution, it is unwise to try and establish a correction factor for any single generator. The only practical solution to the problem therefore is to run a 'blank' sample with each batch of samples drawn from a single tracer solution. (LN)

  13. Normal Values and Reproducibilitiy of Electric Current Perception Threshold in Sensory Fibers

    Directory of Open Access Journals (Sweden)

    Reza Salman-Roghani

    2006-04-01

    Full Text Available Objective: Routine electrodiagnosis (EMG-NCS has some shortcomings in the evaluation of peripheral nervous system, auch as autonomous nervous system evaluation, in pure sensory radiculopathies and acute hyperesthetic stages of neuropathies. Quantitative sensory testings such as current perception threshold (CPT with electrical stimulations are suggested for above mentioned pathologies. Ttest results should be compared with a normal value of similar identical population. This study is conducted to determine normal value and reproducibility of CPT in the Iranian population. Materials & Methods: Fifty normal volunteers (32 men, 18 woman in the range of 20-40 years without exclusion criteria (such as neuro- musculoskeletal disorders, diabetes mellitus and alcoholism were recruited with simple randomized selection and CPT test was conducted on C8 (4th finger and L5 (1st Toedermatomes. To determine test’s reproducibility, 6 persons (4 men, 2 women were examined 3 times a day, 2 day per week. Collected data were analyzed to determine mean and standard deviation. Results: Normal values of CPT test was defined as one standard deviation from mean of our CPT data. These values are in C8 dermatome 2000 Hz: 2.04± 47 250 Hz: 0.75±0.25 5 Hz: 0.76±0.3 and for L5 dermatome 2000Hz: 2.83± 0.73 250 Hz: 1.24 ± 45 5Hz: 0.76± 0.3 To determine our results reproducibility and reliability, Alpha- cronbach (existed in SPSS software was used and %98.5 & 99% were obtained for C8 & L5 dermatomes respectively. Conclusion: Our findings are about C8 & L5 dermatomes which could be used as a normal Values for such dermatomes. Regarding to its good correlation with international results we can use international references as a normal Valueswith consideration of each clinic’s reproducibility should be assessed individually.

  14. Diversification in the Supply Chain of (99)Mo Ensures a Future for (99m)Tc.

    Science.gov (United States)

    Cutler, Cathy S; Schwarz, Sally W

    2014-07-01

    The uncertain availability of (99m)Tc has become a concern for nuclear medicine departments across the globe. An issue for the United States is that currently it is dependent on a supply of (99m)Tc (from (99)Mo) that is derived solely by production outside the United States. Since the United States uses half the world's (99)Mo production, the U.S. (99)Mo supply chain would be greatly enhanced if a producer were located within the United States. The fragility of the old (99)Mo supply chain is being addressed as new facilities are constructed and new processes are developed to produce (99)Mo without highly enriched uranium. The conversion to low-enriched uranium is necessary to minimize the potential misuse of highly enriched uranium in the world for nonpeaceful means. New production facilities, new methods for the production of (99)Mo, and a new generator elution system for the supply of (99m)Tc are currently being pursued. The progress made in all these areas will be discussed, as they all highlight the need to embrace diversity to ensure that we have a robust and reliable supply of (99m)Tc in the future. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  15. 99mTc gel generators based on zirconium molybdate-99Mo: III: Influence of preparatory conditions of zirconium molybdate-99Mo gel on generator performance

    International Nuclear Information System (INIS)

    Saraswathy, P.; Sarkar, S.K.; Arjun, G.; Ramamoorthy, N.; Nandy, S.K.

    2004-01-01

    The effect of subtle variations on zirconium molybdate- 99 Mo gel preparatory conditions, such as stoichiometry of reactants, pH of gel formation, conditioning of gel granules etc., prior to elution were investigated primarily to arrive at the conditions resulting in high 99m Tc release and minimal 99 Mo breakthrough upon elution with normal saline. Zirconium molybdate- 99 Mo gels were prepared by reacting solutions of Zr and Mo in mole ratios of 0.75-1.5. Both water and normal saline were used for gel disintegration, and the release of 99m Tc and 99 Mo from gel columns into eluates was compared. Sharper elution profile of 99m Tc, but with significantly higher 99 Mo breakthrough (5-8 times), was obtained when water alone was used for disintegration and elution, in comparison to when saline was used. Gels exhibiting optimum characteristics were found to be formed at a pH of 4-5 by reacting [Zr]: [Mo] in the mole ratio of 1.25: 1 and after drying, the product was dispersed into granules by disintegration with normal saline. 99m Tc elution efficiency was found to be ∝ 75% and 99 Mo breakthrough ∝ 0.05%. The elution profile was sharp when a 6 g gel column coupled to a 2 g acidic alumina column (to trap 99 Mo) was eluted with 6-9 ml normal saline. Generators containing upto 23 GBq 99 Mo were prepared, eluted extensively without changing the alumina column and found to provide pertechnetate of good quality, commensurate with hospital radiopharmacy requirements. (orig.)

  16. 29 CFR 99.400 - Responsibilities.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Responsibilities. 99.400 Section 99.400 Labor Office of the... Pass-through Entities § 99.400 Responsibilities. (a) Cognizant agency for audit responsibilities... the report submission due date required by § 99.320(a). The cognizant agency for audit may grant...

  17. In-vivo evaluation of standard man model absorbed fractions using /sup 99m/Tc-sulfur colloid

    International Nuclear Information System (INIS)

    Jones, J.P.; Wagner, J.; Brill, A.B.

    1976-01-01

    Results are reported from a study performed to check how well the calculated absorbed radiation dose fraction data (S-factors) given in MIRD Pamphlet No. 5 and related reports apply to living patients administered radionuclides. An external target region was defined on the skin of the Snyder-Fisher phantom, anterior to and overlaying the center of the liver. This target was a 5 cm square by 0.089 cm thick slab of LiF, and the S-factors were computed for this target and uniform distributions of /sup 99m/Tc in the liver and spleen. Experimentally, this target was represented by placing thirteen LiF TLD's of the same thickness in a correspondingly positioned 5 cm square area. An experiment performed with the Mr. Adam phantom showed good agreement between the measured (TLD) and calculated (S-factor) doses. In the patient studies, the group of thirteen TLD's was correspondingly positioned, and the measured TLD dose compared to that calculated from the patient cumulated activity and the Snyder-Fisher phantom S-factors. In most cases, these doses agreed to within 30 percent, although larger discrepancies were observed with non-standard sized patients. Based upon these results, it is desirable to make further investigations of this type, especially with lower energy gamma emitters, and the methods of dose and activity measurement used in this study should be useful unless the photon energy is too low, or the source activity changes rapidly with time

  18. Revealed willingness-to-pay versus standard cost-effectiveness thresholds: Evidence from the South African HIV Investment Case.

    Science.gov (United States)

    Meyer-Rath, Gesine; van Rensburg, Craig; Larson, Bruce; Jamieson, Lise; Rosen, Sydney

    2017-01-01

    The use of cost-effectiveness thresholds based on a country's income per capita has been criticized for not being relevant to decision making, in particular in middle-income countries such as South Africa. The recent South African HIV Investment Case produced an alternative cost-effectiveness threshold for HIV prevention and treatment interventions based on estimates of life years saved and the country's committed HIV budget. We analysed the optimal mix of HIV interventions over a baseline of the current HIV programme under the committed HIV budget for 2016-2018. We calculated the incremental cost-effectiveness ratio (ICER) as cost per life-year saved (LYS) of 16 HIV prevention and treatment interventions over 20 years (2016-2035). We iteratively evaluated the most cost effective option (defined by an intervention and its coverage) over a rolling baseline to which the more cost effective options had already been added, thereby allowing for diminishing marginal returns to interventions. We constrained the list of interventions to those whose combined cost was affordable under the current HIV budget. Costs are presented from the government perspective, unadjusted for inflation and undiscounted, in 2016 USD. The current HIV budget of about $1.6 billion per year was sufficient to pay for the expansion of condom availability, medical male circumcision, universal treatment, and infant testing at 6 weeks to maximum coverage levels, while also implementing a social and behavior change mass media campaign with a message geared at increasing testing uptake and reducing the number of sexual partners. The combined ICER of this package of services was $547/ LYS. The ICER of the next intervention that was above the affordability threshold was $872/LYS. The results of the South African HIV Investment Case point to an HIV cost-effectiveness threshold based on affordability under the current budget of $547-872 per life year saved, a small fraction of the country's GDP per capita of

  19. Revealed willingness-to-pay versus standard cost-effectiveness thresholds: Evidence from the South African HIV Investment Case.

    Directory of Open Access Journals (Sweden)

    Gesine Meyer-Rath

    Full Text Available The use of cost-effectiveness thresholds based on a country's income per capita has been criticized for not being relevant to decision making, in particular in middle-income countries such as South Africa. The recent South African HIV Investment Case produced an alternative cost-effectiveness threshold for HIV prevention and treatment interventions based on estimates of life years saved and the country's committed HIV budget.We analysed the optimal mix of HIV interventions over a baseline of the current HIV programme under the committed HIV budget for 2016-2018. We calculated the incremental cost-effectiveness ratio (ICER as cost per life-year saved (LYS of 16 HIV prevention and treatment interventions over 20 years (2016-2035. We iteratively evaluated the most cost effective option (defined by an intervention and its coverage over a rolling baseline to which the more cost effective options had already been added, thereby allowing for diminishing marginal returns to interventions. We constrained the list of interventions to those whose combined cost was affordable under the current HIV budget. Costs are presented from the government perspective, unadjusted for inflation and undiscounted, in 2016 USD.The current HIV budget of about $1.6 billion per year was sufficient to pay for the expansion of condom availability, medical male circumcision, universal treatment, and infant testing at 6 weeks to maximum coverage levels, while also implementing a social and behavior change mass media campaign with a message geared at increasing testing uptake and reducing the number of sexual partners. The combined ICER of this package of services was $547/ LYS. The ICER of the next intervention that was above the affordability threshold was $872/LYS.The results of the South African HIV Investment Case point to an HIV cost-effectiveness threshold based on affordability under the current budget of $547-872 per life year saved, a small fraction of the country's GDP

  20. Comparison of 99Tcm(V)-DMSA and 99Tcm-MIBI scintigraphy in medullary thyroid carcinoma

    International Nuclear Information System (INIS)

    Deng Bo; Xiao Huan; Chen Xiaofeng; Chen Huaming

    2004-01-01

    SPECT scintigraphy is used in 62 patients with medullary thyroid carcinoma (MTC), which are divided into two groups: 32 patients by 99 Tc m (V)-DMSA and 30 patients by 99 Tc m -MIBI. The qualitative analysis and half quantitative analysis are performed to the early and delayed images. Comparing the results with two groups, there is no difference in the masculine rate of MTC primary focus, but the results of 99 Tc m (V)-DMSA scintigraphy is obviously larger than 99 Tc m -MIBI by half quantitative analysis. The results show that the 99 Tc m (V)-DMSA scintigraphy is more predominant than the 99 Tc m -(V)-DMSA scintigraphy may be superior to 99 Tc m -MIBI in MTC primary focus and metastasis focus before surging for MTC patients. (authors)

  1. Re-evaluation of Moisture Controls During ARIES Oxide Processing, Packaging and Characterization

    Energy Technology Data Exchange (ETDEWEB)

    Karmiol, Benjamin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wayne, David Matthew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-18

    DOE-STD-3013 [1] requires limiting the relative humidity (RH) in the glovebox during processing of the oxide product for specific types of plutonium oxides. This requirement is mandated in order to limit corrosion of the stainless steel containers by deliquescence of chloride salts if present in the PuO2. DOE-STD-3013 also specifies the need to limit and monitor internal pressure buildup in the 3013 containers due to the potential for the generation of free H2 and O2 gas from the radiolysis of surfaceadsorbed water. DOE-STD-3013 requires that the oxide sample taken for moisture content verification be representative of the stabilized material in the 3013 container. This is accomplished by either limiting the time between sampling and packaging, or by control of the glovebox relative humidity (%RH). This requirement ensures that the sample is not only representative, but also conservative from the standpoint of moisture content.

  2. Do we need a threshold conception of competence?

    Science.gov (United States)

    den Hartogh, Govert

    2016-03-01

    On the standard view we assess a person's competence by considering her relevant abilities without reference to the actual decision she is about to make. If she is deemed to satisfy certain threshold conditions of competence, it is still an open question whether her decision could ever be overruled on account of its harmful consequences for her ('hard paternalism'). In practice, however, one normally uses a variable, risk dependent conception of competence, which really means that in considering whether or not to respect a person's decision-making authority we weigh her decision on several relevant dimensions at the same time: its harmful consequences, its importance in terms of the person's own relevant values, the infringement of her autonomy involved in overruling it, and her decision-making abilities. I argue that we should openly recognize the multi-dimensional nature of this judgment. This implies rejecting both the threshold conception of competence and the categorical distinction between hard and soft paternalism.

  3. Generator of {sup 99m} Tc with MnO{sub 2} as support of {sup 99} Mo; Generador de {sup 99m} Tc con MnO{sub 2} como soporte del {sup 99}Mo

    Energy Technology Data Exchange (ETDEWEB)

    Granados C, F.; Serrano G, J. [Departamento de Quimica, Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The generator of {sup 99m} Tc with MnO{sub 2} as support of {sup 99} Mo was studied. By mean of static experiments the retention of {sup 99} Mo in MnO{sub 2} in function of the stirring time and of the p H value of the solution of {sup 99} Mo. It was found that the {sup 99} Mo presents 100% of retention in MnO{sub 2} in the rank of p H 3-11 and the balance was reached before of 10 minutes. In dynamic conditions the retention of {sup 99} Mo in MnO{sub 2} at p H=5 was also higher: 99.72%. The generated {sup 99m} Tc can be separated from {sup 99} Mo, adsorbed in MnO{sub 2} packed in the column, using distilled water at p H=5 or NaCl solution at 0.9%. With saline solution the elution yields were greater than 80% and only an aliquot of 5 ml was necessary for obtaining this yield. The better results were obtained when the column was packed with 1 g of MnO{sub 2}. The water and the saline solution were passed through of the column with a flux of 1.25 ml/min. (Author)

  4. Study of the elution 99Mo-99mTc generators produced at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Lopes, Paula Regina Corain; Osso Junior, Joao Alberto

    2007-01-01

    Over the last years 99m Tc has become a very important asset in modern nuclear medicine, due to the emission of gamma ray of optimal energy (140 keV) and a suitable half-life (6.04 h). A further attribute of 99m Tc is its formation from the decay of 99 Mo and the availability from 99 Mo- 99m Tc generator systems. The most common and practical generator types consist of a chromatographic column packed with aluminium oxide, onto which the highly purified fission product 99 Mo (imported from Canada) is adsorbed in the form of molybdate. 99m Tc is further eluted with saline solution. The objective of this work is to study the performance and the elution profile of 99m Tc from high activity generators in order to decrease molybdenum and aluminium concentration. The experiments involved the use of paper filters and Sep Pak columns and also the changing in the time interval between elutions. 99 Mo breakthrough was measured using a dose calibrator and aluminium by UV-Vis spectrophotometry. The best results were achieved using a Sep Pak column containing neutral aluminium oxide. (author)

  5. 99mTc-Tetrofosmin scintimammography in suspected breast cancer patients: comparison with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Kim, Seong Jang; Kim, In Ju; Kim, Yong Ki; Bae, Young Tae

    2000-01-01

    The aim of this study was to investigate the diagnostic role of 99m Tc-Tetrofosmin in detection of breast cancer and compared with that of 99m Tc-MIBI. Forty-eight patients with a clinically palpable mass or abnormal mammographic or ultrasonographic findings had 99m Tc-MIBI and 99m Tc-Tetrofosmin scintimammographies after intravenous injection of 925 MBq of radiopharmaceuticals. The scintimammographs were correlated with histopathologic findings. Thirty-three patients were diagnosed with breast cancer and 15 patients with benign breast diseases. The numbers of true positive, true negative, false positive, and false negative cases of 99m Tc-MIBI scintimammography were 29, 10, 5, and 4 respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of 99m Tc-MIBI scintimammographies were 87.8%, 66.7%, 85.3%, and 71.4% respectively. The numbers of true positive, true negative, false positive, and false negative cases of 99m Tc-Tetrofosmin were 31, 10, 5, and 2 respectively. The sensitivity, specificity, positive predictive value, negative predictive value of 99m Tc-Tetrofosmin were 93.9%, 66.7%, 86.1%, and 73.3% respectively. One patient was false negative in both 99m Tc-Tetrofosmin scintimammographies and its size was 0.5cm. 99m Tc-Tetrofosmin and 99m Tc-MIBI were non-invasive and useful in detection of breast cancer and 99m Tc-Tetrofosmin was comparable to the 99m Tc-MIBI in detection of primary breast cancer.=20

  6. 29 CFR 99.105 - Definitions.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Definitions. 99.105 Section 99.105 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS General § 99.105 Definitions. Audit finding means deficiencies which the auditor is required by § 99.510(a) to report in the...

  7. Standard deviation index for stimulated Brillouin scattering suppression with different homogeneities.

    Science.gov (United States)

    Ran, Yang; Su, Rongtao; Ma, Pengfei; Wang, Xiaolin; Zhou, Pu; Si, Lei

    2016-05-10

    We present a new quantitative index of standard deviation to measure the homogeneity of spectral lines in a fiber amplifier system so as to find the relation between the stimulated Brillouin scattering (SBS) threshold and the homogeneity of the corresponding spectral lines. A theoretical model is built and a simulation framework has been established to estimate the SBS threshold when input spectra with different homogeneities are set. In our experiment, by setting the phase modulation voltage to a constant value and the modulation frequency to different values, spectral lines with different homogeneities can be obtained. The experimental results show that the SBS threshold increases negatively with the standard deviation of the modulated spectrum, which is in good agreement with the theoretical results. When the phase modulation voltage is confined to 10 V and the modulation frequency is set to 80 MHz, the standard deviation of the modulated spectrum equals 0.0051, which is the lowest value in our experiment. Thus, at this time, the highest SBS threshold has been achieved. This standard deviation can be a good quantitative index in evaluating the power scaling potential in a fiber amplifier system, which is also a design guideline in suppressing the SBS to a better degree.

  8. Project Execution Plan Project 98L-EWW-460 Plutonium Stabilization and Handling DOE 98-D-453

    Energy Technology Data Exchange (ETDEWEB)

    HOLSTEIN, W.A.

    1999-08-01

    This Project Execution Plan (PEP) describes the management methods and responsibilities of the project participants. Project W-460 is sufficiently large to warrant a stand alone PEP. This project specific PEP describes the relationships and responsibilities of the project team and identifies the technical, schedule, and cost baselines that have been established for the project. The Department of Energy (DOE), Hanford Works (Hanford), at Richland Wa. currently does not have a system capable of stabilizing or packaging large quantities of plutonium-bearing solids to meet DOE technical standard DOE-STD-3013-96. This project will allow Hanford to meet this standard by installing stabilization and packaging equipment (SPE). The SPE is capable of stabilizing and packaging the current inventory of greater than 50 percent plutonium-bearing materials currently stored in the Plutonium Finishing Plant's (PFP) vaults into 3013 storage containers. The scope of this project is to procure and install the SPE via a Hanford contract and coordination with the Savannah River Site. In addition, the project will modify PFP vaults and upgrade the PFP Laboratory measurement systems. The Facility infrastructure will be modified to support the new SPE system and the new standardized storage container configuration.

  9. Preparation of clinical-scale 99Mo/99mTc column generator using neutron activated low specific activity 99Mo and nanocrystalline γ-Al2O3 as column matrix.

    Science.gov (United States)

    Chakravarty, Rubel; Ram, Ramu; Dash, Ashutosh; Pillai, M R A

    2012-10-01

    Preparation of clinical-scale (99)Mo/(99m)Tc generator using (n,γ) activated low specific activity (99)Mo and nanocrystalline γ-Al(2)O(3) as a high capacity sorbent matrix is attempted. Nanocrystalline γ-Al(2)O(3) was synthesized by 'solid state mechanochemical' reaction of aluminum nitrate with ammonium bicarbonate. Experimental parameters were optimized to effectively separate (99m)Tc from (99)Mo using this sorbent as the column matrix. The performance features of a 13 GBq (350 mCi) (99)Mo/(99m)Tc generator using this sorbent and (99)Mo produced by (n,γ) route having specific activity 12.9-18.5 GBq/g were evaluated for 10 days. The sorbent possessed the requisite selectivity for (99)Mo and demonstrated a maximum sorption capacity of 200 ± 5mg Mo/g, which is ~10 times higher than that of ordinary acidic alumina. The overall yield of (99m)Tc was >80%, with radionuclidic purity >99.99% and radiochemical purity >99%. The yield of (99m)Tc varied from 7.8 to 2.1 GBq in the eluate for the six days of operation of the generator. The radioactive concentration of (99m)Tc eluted was adequate for the formulation of radiopharmaceuticals. The performance of the generator remained consistent over an extended period of 10 days. The eluted (99m)Tc was suitable for the formulation of (99m)Tc-DMSA and (99m)Tc-EC resulting in high radiolabeling yields (>98%). The effectiveness of γ-Al(2)O(3) as a new generation sorbent in the development of clinically useful (99)Mo/(99m)Tc generator using low specific activity (99)Mo and yielding (99m)Tc with adequate radioactive concentration and high purity suitable for formulation of radiopharmaceuticals is demonstrated. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Quality control studies of {sup 99}Mo used in {sup 99}Mo/{sup 99m}Tc generators produced at IPEN/CNEN-SP, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Said, Daphne S.; Brambilla, Tania P.; Matsuda, Margareth M.N.; Osso Junior, Joao A., E-mail: daphnesaid@usp.br, E-mail: taniabrambilla@yahoo.com.br, E-mail: mmatsuda@ipen.br, E-mail: jaosso@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    {sup 99m}Tc is the most used radionuclide in nuclear medicine. In Brazil, the {sup 99}Mo/{sup 99m}Tc generators are produced exclusively by the Center of Radiopharmacy at IPEN-CNEN/SP, by importing {sup 99}Mo from different suppliers. {sup 99}Mo (t{sub 1/2} = 66 h) is a fission product of {sup 235}U, therefore, it can be accompanied by several radioisotopes that are highly prejudicial for human health, demanding a strict quality control of this product for generators safe use. The European Pharmacopoeia established some parameters and limits that evaluate the quality of the solution of sodium [{sup 99}Mo]molybdate, that is used as raw material for generator's production. The European Pharmacopoeia also recommends some analytical methods to perform these evaluations, however, it has been observed difficulties on the implementation of these methods by the generator's producers. These difficulties are probably related to the lack of practicability of the proposed methods and the extensive list of utilized reagents. In this work some procedures of the European Pharmacopoeia's quality control method for {sup 99}Mo were evaluated. Different types of solid phase exchanger cartridges were tested for retention of {sup 99}Mo in 3 different conditions. Cartridges that presented percentages of retention higher than 90% were also tested for separation of {sup 99}Mo from possible contaminants (Ru e Te). The results shown that solid phase exchanger cartridges that presented percentages of retention of Mo higher than 90% also presented significant percentages of retention of Ru and Te. An alternative method for separation of {sup 99}Mo from {sup 131}I (other contaminant) are also proposed. (author)

  11. The Standard of Proof in Criminal Proceedings: the Threshold to ...

    African Journals Online (AJOL)

    Hanna_AZ

    The standard of proof, along with other basic notions in the law of evidence, ... testimony. Among the different theories and formulations surrounding the beyond a .... rule, the prosecution are obliged (i) to prove that the accused committed the.

  12. Indigenous technology development and standardization of the process for obtaining ready to use sterile sodium pertechnetate-Tc-99m solution from Geltech generator

    International Nuclear Information System (INIS)

    Sarkar, Sishir Kumar; Kothalkar, Chetan; Naskar, Prabhakar; Joshi, Sangeeta; Saraswathy, Padmanabhan; Dey, Arun Chandra; Vispute, Gunvant Leeladhar; Murhekar, Vishwas Vinayak; Pilkhwal, Neelam

    2013-01-01

    The indigenous design and technology development for processing large scale zirconium molybdate-Mo-99 (ZrMo-99) Geltech generator was successfully commissioned in Board of Radiation and Isotope Technology (BRIT), India, in 2006. The generator production facility comprises of four shielded plant facilities equipped with tongs and special process gadgets amenable for remote operations for radiochemical processing of ZrMo-99 gel. Over 2800 Geltech generators have been processed and supplied to user hospitals during the period 2006-2013. Geltech generator supplied by BRIT was initially not sterile. Simple elution of 99m Tc is performed by a sterile evacuated vial with sterile and pyrogen free 0.9% NaCl solution to obtain sodium ( 99m Tc) pertechnetate solution. A special type online 0.22 μm membrane filter has been identified and adapted in Geltech generator. The online filtration of 99m Tc from Geltech generator; thus, provided sterile 99m Tc sodium pertechnetate solution. Generators assembled with modified filter assembly were supplied to local hospital in Mumbai (Radiation Medicine Centre (RMC) and S.G.S. Medical College and KEM Hospital) and excellent performances were reported by users. (author)

  13. Indigenous technology development and standardization of the process for obtaining ready to use sterile sodium pertechnetate-Tc-99m solution from Geltech generator.

    Science.gov (United States)

    Sarkar, Sishir Kumar; Kothalkar, Chetan; Naskar, Prabhakar; Joshi, Sangeeta; Saraswathy, Padmanabhan; Dey, Arun Chandra; Vispute, Gunvant Leeladhar; Murhekar, Vishwas Vinayak; Pilkhwal, Neelam

    2013-04-01

    The indigenous design and technology development for processing large scale zirconium molybdate-Mo-99 (ZrMo-99) Geltech generator was successfully commissioned in Board of Radiation and Isotope Technology (BRIT), India, in 2006. The generator production facility comprises of four shielded plant facilities equipped with tongs and special process gadgets amenable for remote operations for radiochemical processing of ZrMo-99 gel. Over 2800 Geltech generators have been processed and supplied to user hospitals during the period 2006-2013. Geltech generator supplied by BRIT was initially not sterile. Simple elution of Tc-99m is performed by a sterile evacuated vial with sterile and pyrogen free 0.9% NaCl solution to obtain sodium (Tc-99m) pertechnetate solution. A special type online 0.22 μm membrane filter has been identified and adapted in Geltech generator. The online filtration of Tc-99m from Geltech generator; thus, provided sterile Tc-99m sodium pertechnetate solution. Generators assembled with modified filter assembly were supplied to local hospital in Mumbai Radiation Medicine Centre (RMC) and S.G.S. Medical College and KEM Hospital) and excellent performances were reported by users.

  14. A {sup 99m}Tc Generator using PZC for (n,{gamma}) {sup 99}Mo

    Energy Technology Data Exchange (ETDEWEB)

    Adang, H G; Mutalib, A; Suparman, I; Hamid,; Purwadi, B; Pancoko, M; Setiowati, S; Yulianti, V; Robertus, D H [Radioisotope Production Center, National Atomic Energy Agency Kawasan PUSPIPTEK, Serpong (Indonesia)

    1998-10-01

    The high performance adsorbent Poly Zirconium Compound (PZC) was produced by Department of Radioisotope, Japan Atomic Energy Research Institute. This compound was developed as an adsorbent for natural Mo (n,{gamma}) {sup 99}Mo-{sup 99m}Tc Generator. In the present paper, we report the performance of the PZC for a {sup 99m}Tc Generator which was focused on the yield, on elution profile and {sup 99}Mo breakthrough. (author)

  15. Improving the segmentation of therapy-induced leukoencephalopathy using apriori information and a gradient magnitude threshold

    Science.gov (United States)

    Glass, John O.; Reddick, Wilburn E.; Reeves, Cara; Pui, Ching-Hon

    2004-05-01

    Reliably quantifying therapy-induced leukoencephalopathy in children treated for cancer is a challenging task due to its varying MR properties and similarity to normal tissues and imaging artifacts. T1, T2, PD, and FLAIR images were analyzed for a subset of 15 children from an institutional protocol for the treatment of acute lymphoblastic leukemia. Three different analysis techniques were compared to examine improvements in the segmentation accuracy of leukoencephalopathy versus manual tracings by two expert observers. The first technique utilized no apriori information and a white matter mask based on the segmentation of the first serial examination of each patient. MR images were then segmented with a Kohonen Self-Organizing Map. The other two techniques combine apriori maps from the ICBM atlas spatially normalized to each patient and resliced using SPM99 software. The apriori maps were included as input and a gradient magnitude threshold calculated on the FLAIR images was also utilized. The second technique used a 2-dimensional threshold, while the third algorithm utilized a 3-dimensional threshold. Kappa values were compared for the three techniques to each observer, and improvements were seen with each addition to the original algorithm (Observer 1: 0.651, 0.653, 0.744; Observer 2: 0.603, 0.615, 0.699).

  16. Targeting osteomyelitis with complete [99mTc]besilesomab and fragmented [99mTc]sulesomab antibodies: kinetic evaluations

    International Nuclear Information System (INIS)

    GRATZ, Stefan; KEMKE, Bendix; KEIZE, Patrik; KAMPEN, Wim U.; LUSTER, Markus; HÖFFKEN, Helmut

    2016-01-01

    The aim of this retrospective study was to compare the targeting of “pure” osteomyelitis (i.e., without surrounding soft tissue infection) by directly 99mTc-labelled complete immunoglobulin G (IgG) monoclonal antibody (MAb) ([99mTc]besilesomab) and by directly 99mTc-labelled fragment antigen-binding (FAb) MAb ([99mTc]sulesomab) in relation to their kinetic fate. A total of 73 patients with “pure” osteomyelitis were examined with [99mTc]besilesomab, (Scintimun®, IBA/CIS bio international, Saclay, France; N.=38) and [99mTc]sulesomab (LeukoScan®, Immunomedics Inc., Morris Plains, NJ, USA; N.=35). Kinetic data were deduced from whole-body and single-photon emission computed tomographic scans, performed 10 minutes to 24 hour p.i. (region-of-interest technique [ROI]). In targeting “pure” osteomyelitis, sensitivities at 1-4 hours were found to be higher for [99mTc]sulesomab (44% and 80% for [99mTc]besilesomab and [99mTc]sulesomab, respectively) but at significantly lower target/background (T/B) ratios than with [99mTc]besilesomab (1.8±0.3 versus 1.4±0.5 for [99mTc]besilesomab and [99mTc]sulesomab respectively; P<0.01). With [99mTc]besilesomab, there was a continuous osteomyelitis uptake over 24 hours, whereas with [99mTc]sulesomab, the maximal uptake occurred mostly within 1-4 hours, with subsequent clearance being slower for antigen-bound activity than for nonspecific background. Hence, diagnosis was possible mostly after 4h with [99mTc]sulesomab but often not before 24 hours with [99mTc]besilesomab, the later increasing significantly (P<0.01) in sensitivity (87% and 84% for [99mTc]besilesomab and [99mTc]sulesomab, respectively). These results show that the higher sensitivity of [99mTc]sulesomab in osteomyelitis targeting at earlier p.i. times does not rely on an increased antibody uptake but on a more rapid clearance of nonspecific background activity due to faster metabolism and excretion. Intact [99mTc]besilesomab show a slow, continuous uptake

  17. Method of producing molybdenum-99

    Science.gov (United States)

    Pitcher, Eric John

    2013-05-28

    Method of producing molybdenum-99, comprising accelerating ions by means of an accelerator; directing the ions onto a metal target so as to generate neutrons having an energy of greater than 10 MeV; directing the neutrons through a converter material comprising techentium-99 to produce a mixture comprising molybdenum-99; and, chemically extracting the molybdenum-99 from the mixture.

  18. Intermediate structure and threshold phenomena

    International Nuclear Information System (INIS)

    Hategan, Cornel

    2004-01-01

    The Intermediate Structure, evidenced through microstructures of the neutron strength function, is reflected in open reaction channels as fluctuations in excitation function of nuclear threshold effects. The intermediate state supporting both neutron strength function and nuclear threshold effect is a micro-giant neutron threshold state. (author)

  19. 99mTc-MIBI, 99mTc-tetrofosmin and 99mTc-Q12 in vitro and in vivo

    International Nuclear Information System (INIS)

    Bernard, Bert F.; Krenning, Eric P.; Breeman, Wout A. P.; Ensing, Geert; Benjamins, Harry; Bakker, Willem H.; Visser, Theo J.; Jong, Marion de

    1998-01-01

    The aim of this study was to compare uptake of 99m Tc-MIBI, 99m Tc-tetrofosmin and 99m Tc-Q12 in vitro and biodistribution in vivo in rats. In vitro, uptake decreased in the order MIBI→tetrofosmin→Q12. Uptake of MIBI and tetrofosmin, but not of Q12, in cultured tumor cells was dependent on the plasma membrane and mitochondrial potential. In vivo, heart uptake of all three compounds was high and stable. Tumor uptake decreased in the order MIBI→Q12→tetrofosmin and the tumor/blood ratio in the order MIBI→tetrofosmin→Q12

  20. Comparison of relative renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured with 99m Tc-DMSA static scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Domingues, F.C.; Fujikawa, G.Y.; Decker, H.; Alonso, G.; Pereira, J.C.; Duarte, P.S. [Centro de Diagnostico Fleury, Sao Paulo, SP (Brazil). Secao de Medicina Nuclear; Sao Paulo Univ. (USP), SP (Brazil). Escola de Saude Publica. Dept. de Epidemiologia]. E-mail: paulo.duarte@fleury.com.br

    2006-07-15

    Objective: The aim of this study was to compare the renal function measured with either {sup 99m}Tc-DTPA or {sup 99m}Tc-EC dynamic scintigraphies with that measured using {sup 99m}Tc-DMSA static scintigraphy. Methods: the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with {sup 99m}Tc-DTPA (55 studies) or with {sup 99m}Tc-EC (56 studies) were compared with the relative function measured using {sup 99m}Tc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of {sup 99m}Tc-DTPA and {sup 99m}Tc-EC studies that presented relative renal function different by more than 5% from that measured with {sup 99m}Tc-DMSA, using chi square test were also compared. Results: the relative renal function measured with {sup 99m}Tc-EC is not statistically different from that measured with {sup 99m}Tc-DMSA (p = 0.97). The relative renal function measured with {sup 99m}Tc-DTPA was statistically different from that measured using {sup 99m}Tc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5% from that measured with {sup 99m}Tc-DMSA is higher for the {sup 99m}Tc-DTPA scintigraphy (p 0.04) than for {sup 99m}Tc-EC. Conclusion: the relative renal function measured with {sup 99m}Tc-EC dynamic scintigraphy is comparable with that measured with {sup 99m}Tc-DMSA static scintigraphy, while the relative renal function measured with {sup 99m}Tc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with {sup 99m}Tc-DMSA static scintigraphy. (author)

  1. Comparison of relative renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured with 99m Tc-DMSA static scintigraphy

    International Nuclear Information System (INIS)

    Domingues, F.C.; Fujikawa, G.Y.; Decker, H.; Alonso, G.; Pereira, J.C.; Duarte, P.S.; Sao Paulo Univ.

    2006-01-01

    Objective: The aim of this study was to compare the renal function measured with either 99m Tc-DTPA or 99m Tc-EC dynamic scintigraphies with that measured using 99m Tc-DMSA static scintigraphy. Methods: the values of relative renal function measured in 111 renal dynamic scintigraphies performed either with 99m Tc-DTPA (55 studies) or with 99m Tc-EC (56 studies) were compared with the relative function measured using 99m Tc-DMSA static scintigraphy performed within a 1-month period. The comparisons were performed using Wilcoxon signed rank test. The number of 99m Tc-DTPA and 99m Tc-EC studies that presented relative renal function different by more than 5% from that measured with 99m Tc-DMSA, using chi square test were also compared. Results: the relative renal function measured with 99m Tc-EC is not statistically different from that measured with 99m Tc-DMSA (p = 0.97). The relative renal function measured with 99m Tc-DTPA was statistically different from that measured using 99m Tc-DMSA, but with a borderline statistical significance (p = 0.05). The number of studies with relative renal function different by more than 5% from that measured with 99m Tc-DMSA is higher for the 99m Tc-DTPA scintigraphy (p 0.04) than for 99m Tc-EC. Conclusion: the relative renal function measured with 99m Tc-EC dynamic scintigraphy is comparable with that measured with 99m Tc-DMSA static scintigraphy, while the relative renal function measured with 99m Tc-DTPA dynamic scintigraphy presents a significant statistical difference from that measured with 99m Tc-DMSA static scintigraphy. (author)

  2. In-house cyclotron production of high-purity Tc-99m and Tc-99m radiopharmaceuticals.

    Science.gov (United States)

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Zagni, Federico; Corazza, Andrea; Uccelli, Licia; Pasquali, Micòl; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Skliarova, Hanna; Mou, Liliana; Cisternino, Sara; Carturan, Sara; Melendez-Alafort, Laura; Uzunov, Nikolay M; Bello, Michele; Alvarez, Carlos Rossi; Esposito, Juan; Duatti, Adriano

    2018-05-30

    In the last years, the technology for producing the important medical radionuclide technetium-99m by cyclotrons has become sufficiently mature to justify its introduction as an alternative source of the starting precursor [ 99m Tc][TcO 4 ] - ubiquitously employed for the production of 99m Tc-radiopharmaceuticals in hospitals. These technologies make use almost exclusively of the nuclear reaction 100 Mo(p,2n) 99m Tc that allows direct production of Tc-99m. In this study, it is conjectured that this alternative production route will not replace the current supply chain based on the distribution of 99 Mo/ 99m Tc generators, but could become a convenient emergency source of Tc-99m only for in-house hospitals equipped with a conventional, low-energy, medical cyclotron. On this ground, an outline of the essential steps that should be implemented for setting up a hospital radiopharmacy aimed at the occasional production of Tc-99m by a small cyclotron is discussed. These include (1) target production, (2) irradiation conditions, (3) separation/purification procedures, (4) terminal sterilization, (5) quality control, and (6) Mo-100 recovery. To address these issues, a comprehensive technology for cyclotron-production of Tc-99m, developed at the Legnaro National Laboratories of the Italian National Institute of Nuclear Physics (LNL-INFN), will be used as a reference example. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Separation of sup(99m)Tc from 99MoO3

    International Nuclear Information System (INIS)

    Tomicic, M.

    1977-07-01

    At the present time sup(99m)Tc is widely used in nuclear medicine and its uses are increasing. It can be produced by various methods, and of those most frequently used today two have special features making them particularly applicable to the large-scale production of instant sup(99m)Tc - these are solvent extraction with methyl-ethyl-ketone and the sublimation methods. This report presents a bibliographic review of these methods, their main perfomance parameters, and experience obtained from the development and operation of a sublimation generator. Separation of sup(99m)Tc from irradiated MoO 3 was carried out with high yields (75-95%) after multiple repetition of the separation process with molybdenum trioxide heated for half an hour at a maximum temperature of 850-890 deg C in an air flow. The activity ratio of molybdenum in the separated sup(99m)Tc was of the order of 4 x 10 -5 . (author)

  4. Nuclear threshold effects and neutron strength function

    International Nuclear Information System (INIS)

    Hategan, Cornel; Comisel, Horia

    2003-01-01

    One proves that a Nuclear Threshold Effect is dependent, via Neutron Strength Function, on Spectroscopy of Ancestral Neutron Threshold State. The magnitude of the Nuclear Threshold Effect is proportional to the Neutron Strength Function. Evidence for relation of Nuclear Threshold Effects to Neutron Strength Functions is obtained from Isotopic Threshold Effect and Deuteron Stripping Threshold Anomaly. The empirical and computational analysis of the Isotopic Threshold Effect and of the Deuteron Stripping Threshold Anomaly demonstrate their close relationship to Neutron Strength Functions. It was established that the Nuclear Threshold Effects depend, in addition to genuine Nuclear Reaction Mechanisms, on Spectroscopy of (Ancestral) Neutron Threshold State. The magnitude of the effect is proportional to the Neutron Strength Function, in their dependence on mass number. This result constitutes also a proof that the origins of these threshold effects are Neutron Single Particle States at zero energy. (author)

  5. SELECTED REQUIREMENTS OF INTEGRATED MANAGEMENT SYSTEMS BASED ON PAS 99 SPECIFICATION

    Directory of Open Access Journals (Sweden)

    Paweł Nowicki

    2013-03-01

    Full Text Available The aim this research was to analyze the ways of integration of management systems in food sector. The study involved the documentation, audits, corrective and preventive actions and management's review phases described in the specification PAS 99, which is one of common elements of integrated management systems. Four organizations were selected for the study. The organizations had introduced and certified at least two standardized management systems. It was assumed that the investigated organizations should have implemented the HACCP system. Studies were conducted as a case study. The employees responsible for the functioning of management systems were interviewed in all four organizations. The study was conducted in the form of in-depth interviews based on pre-prepared script. The scenario was developed based on the PAS 99 guideline. The process of integration of management systems implemented in the studied companies reveals the full compliance of an integrated management system with PASS 99 in the policy area.

  6. Influence of the electrolyte in the fixation of {sup 99} Mo in hydroxyapatite as matrix of the {sup 99} Mo/ {sup 99m} Tc generator; Influencia del electrolito en la fijacion de {sup 99} Mo en hidroxiapatita coma matriz del generador {sup 99} Mo/ {sup 99m} Tc

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez G, S.; Badillo A, V.E. [UAZ, Zacatecas (Mexico); Monroy G, F. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: s_vazgro@hotmail.com

    2005-07-01

    The more used isotope at the moment in the services of nuclear medicine in the world is the technetium-99m. The {sup 99m} Tc emitts gamma rays of 141 keV and it semi disintegration period is of six hours, given it short half life, to produce it is necessary to order generators that are systems that allow to separate periodically at the {sup 99m}Tc of the {sup 99} Mo by means of chromatographic techniques. In this work it is sought to evaluate the use of the hydroxyapatite, to separate molybdates {sup 99} MoO{sub 4}{sup 2} of pertechnetates {sup 99m}TcO{sub 4}{sup -} and to be able to determine if it is feasible their use for to build generators of {sup 99m} Tc. With this purpose preliminary tests to know the likeness of the hydroxyapatite for the molybdates in function of the pH value, in different solutions were carried out: one of NaCl 0.9%, NaCl 2% and CaCl{sub 2} 0.01 M. The obtained results in a NaCl 0.9% solution and at to 2% to different pH values of the solution, shows that the fixation of the molybdate ions (MoO{sub 4}{sup -2}) it is worthless to basic pH values of (9-11), as long as in solution of CaCI{sub 2} 0.01 M show a considerable retention of molybdate ions. (Author)

  7. Utility of 99mTc-GHA Brain SPECT in the grading of brain tumors

    International Nuclear Information System (INIS)

    Bhattacharya, Anish; Mittal, B.R.; Kumar, Ashok

    2004-01-01

    Full text: Brain tumors are of diverse histological types, the most common being derived from glial tissue. The clinical management and prognosis of brain tumor patients is dependent on accurate neuro-pathologic diagnosis and grading. Radiological imaging is not always a good modality for assessing the exact nature and grade of a malignant tumor. Magnetic resonance imaging (MRI) has a very high soft tissue resolution and is helpful in classifying the grade of tumor. Radionuclide imaging techniques that can reveal metabolic activity within tumor cells are very helpful in predicting the degree of malignancy. Usefulness of Tl-201 SPECT and FDG PET studies have been widely reported to evaluate malignant lesions by measuring increased regional glucose metabolism and amino acid uptake. 99mTc-GHA (Glucoheptonate), more or less analogous to 18F-FDG, may show increased glucose metabolism and help in grading tumors. This study was carried out to determine the utility of 99mTc-GHA SPECT for grading cerebral gliomas. Nineteen patients (12M, 7F) aged 22 to 51 years (36.1 ± 8.3) diagnosed clinically and radiologically to have a brain tumor were evaluated with 99mTc-GHA brain SPECT. All the patients had undergone CT/ MRI examination prior to the brain SPECT study. No patient had undergone surgery, radiation therapy or chemotherapy before the imaging studies. Brain SPECT was performed twice, i.e 40 min and 3 hours after intravenous administration of 20 mCi of Tc99m-GHA under a dual head SPECT gamma camera (Ecam, Siemens), with a low energy high-resolution collimator. A total of 128 frames of 30 seconds each, 64 per detector, were acquired in 128 x 128 matrix, with 360-degree rotation in step and shoot mode. Reconstruction of the SPECT data was done using standard software. Abnormal concentration of tracer at the tumor site was compared to normal uptake on the contralateral side, and ratios obtained for early (40 min) and delayed (3 hours) uptake of tracer. Retention ratio (RR), a

  8. 32 CFR 99.3 - General definitions.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 1 2010-07-01 2010-07-01 false General definitions. 99.3 Section 99.3 National... PROCEDURES FOR STATES AND LOCALITIES TO REQUEST INDEMNIFICATION § 99.3 General definitions. For the purposes of §§ 99.1 through 99.9 of this part: Criminal history record information: information collected by...

  9. Otsu Based Optimal Multilevel Image Thresholding Using Firefly Algorithm

    Directory of Open Access Journals (Sweden)

    N. Sri Madhava Raja

    2014-01-01

    Full Text Available Histogram based multilevel thresholding approach is proposed using Brownian distribution (BD guided firefly algorithm (FA. A bounded search technique is also presented to improve the optimization accuracy with lesser search iterations. Otsu’s between-class variance function is maximized to obtain optimal threshold level for gray scale images. The performances of the proposed algorithm are demonstrated by considering twelve benchmark images and are compared with the existing FA algorithms such as Lévy flight (LF guided FA and random operator guided FA. The performance assessment comparison between the proposed and existing firefly algorithms is carried using prevailing parameters such as objective function, standard deviation, peak-to-signal ratio (PSNR, structural similarity (SSIM index, and search time of CPU. The results show that BD guided FA provides better objective function, PSNR, and SSIM, whereas LF based FA provides faster convergence with relatively lower CPU time.

  10. Measurement and Estimation of the 99Mo Production Yield by 100Mo(n,2n)99Mo

    Science.gov (United States)

    Minato, Futoshi; Tsukada, Kazuaki; Sato, Nozomi; Watanabe, Satoshi; Saeki, Hideya; Kawabata, Masako; Hashimoto, Shintaro; Nagai, Yasuki

    2017-11-01

    We, for the first time, measured the yield of 99Mo, the mother nuclide of 99mTc used in nuclear medicine diagnostic procedures, produced by the 100Mo(n,2n)99Mo reaction with accelerator neutrons. The neutrons with a continuous energy spectrum from the thermal energy up to about 40 MeV were provided by the C(d,n) reaction with 40 MeV deuteron beams. It was proved that the 99Mo yield agrees with that estimated by using the latest data on neutrons from the C(d,n) reaction and the evaluated cross section of the 100Mo(n,2n)99Mo reaction given in the Japanese Evaluated Nuclear Data Library. On the basis of the agreement, a systematic calculation was carried out to search for an optimum condition that enables us to produce as much 99Mo as possible with a good 99Mo/100Mo value from an economical point of view. The calculated 99Mo yield from a 150 g 100MoO3 sample indicated that about 30% of the demand for 99Mo in Japan can be met with a single accelerator capable of 40 MeV, 2 mA deuteron beams. Here, by referring to an existing 18F-fluorodeoxyglucose (FDG) distribution system we assumed that 99mTc radiopharmaceuticals formed after separating 99mTc from 99Mo can be delivered to hospitals from a radiopharmaceutical company within 6 h. The elution of 99mTc from 99Mo twice a day would meet about 50% of the demand for 99Mo.

  11. Relationship of end-expiratory pressure, lung volume, and /sup 99m/Tc-DTPA clearance

    International Nuclear Information System (INIS)

    Cooper, J.A.; van der Zee, H.; Line, B.R.; Malik, A.B.

    1987-01-01

    We investigated the dose-response effect of positive end-expiratory pressure (PEEP) and increased lung volume on the pulmonary clearance rate of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA). Clearance of lung radioactivity was expressed as percent decrease per minute. Base-line clearance was measured while anesthetized sheep (n = 20) were ventilated with 0 cmH 2 O end-expiratory pressure. Clearance was remeasured during ventilation at 2.5, 5, 10, 15, or 20 cmH 2 O PEEP. Further studies showed stepwise increases in functional residual capacity (FRC) (P less than 0.05) measured at 0, 2.5, 5, 10, 15, and 20 cmH 2 O PEEP. At 2.5 cmH 2 O PEEP, the clearance rate was not different from that at base line (P less than 0.05), although FRC was increased from base line. Clearance rate increased progressively with increasing PEEP at 5, 10, and 15 cmH 2 O (P less than 0.05). Between 15 and 20 cmH 2 O PEEP, clearance rate was again unchanged, despite an increase in FRC. The pulmonary clearance of aerosolized /sup 99m/Tc-DTPA shows a sigmoidal response to increasing FRC and PEEP, having both threshold and maximal effects. This relationship is most consistent with the hypothesis that alveolar epithelial permeability is increased by lung inflation

  12. A New Wavelet Threshold Function and Denoising Application

    Directory of Open Access Journals (Sweden)

    Lu Jing-yi

    2016-01-01

    Full Text Available In order to improve the effects of denoising, this paper introduces the basic principles of wavelet threshold denoising and traditional structures threshold functions. Meanwhile, it proposes wavelet threshold function and fixed threshold formula which are both improved here. First, this paper studies the problems existing in the traditional wavelet threshold functions and introduces the adjustment factors to construct the new threshold function basis on soft threshold function. Then, it studies the fixed threshold and introduces the logarithmic function of layer number of wavelet decomposition to design the new fixed threshold formula. Finally, this paper uses hard threshold, soft threshold, Garrote threshold, and improved threshold function to denoise different signals. And the paper also calculates signal-to-noise (SNR and mean square errors (MSE of the hard threshold functions, soft thresholding functions, Garrote threshold functions, and the improved threshold function after denoising. Theoretical analysis and experimental results showed that the proposed approach could improve soft threshold functions with constant deviation and hard threshold with discontinuous function problems. The proposed approach could improve the different decomposition scales that adopt the same threshold value to deal with the noise problems, also effectively filter the noise in the signals, and improve the SNR and reduce the MSE of output signals.

  13. Environmental behavior of technetium-99

    International Nuclear Information System (INIS)

    Turcotte, M.D.S.

    1982-12-01

    This report presents a review of the literature on technetium-99. The chemical and physical properties of some technetium compounds are considered, and a discussion of possible source terms is included. Literature on the environmental behavior of technetium is presented, including its behavior in the bodies of animals and humans. The primary sources of Tc-99 in the environment are fallout from atomic detonations and releases from nuclear fuel reprocessing plants. The environmental behavior of technetium-99 has been studied predominantly with respect to movement in soil and accumulation in plants. There is a surprising scarcity of data on behavior of Tc-99 in the atmosphere and in aquatic systems. Additional work needs to be conducted in these two areas to determine behavior and to acquire baseline concentration data. Much of the soil work has produced contradictory results. In-depth studies of holdup mechanisms for Tc-99 in both geological repositories and soil need to be conducted. Since plants represent a potential bioaccumulation of Tc-99, plant uptake studies of Tc-99 under field conditions also need to be done

  14. {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin: relative retention and clearance kinetics in retrogradely perfused guinea pig hearts

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Wolfgang M.; Moka, Detlef E-mail: detlef.moka@uni-koeln.de; Brockmann, Holger A.; Schomaecker, Klaus; Schicha, Harald

    2002-02-01

    Myocellular kinetics of {sup 201}Tl, {sup 99m}Tc-MIBI, {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin were investigated using retrogradely-perfused guinea-pig hearts. Relative retention decreased in the order {sup 99m}Tc-MIBI {yields}{yields} implies {sup 99m}Tc-tetrofosmin {yields}{yields} implies {sup 99m}Tc-furifosmin. {sup 201}Tl and {sup 99m}Tc-MIBI exhibited bi- (t1,t2), {sup 99m}Tc-tetrofosmin and {sup 99m}Tc-furifosmin triexponential (t1,t2,t3) time-activity-curves. Latest-phase elimination-half-life increased from {sup 201}Tl (t2) {yields}{yields} implies {sup 99m}Tc-MIBI (t2) {yields}{yields} implies {sup 99m}Tc-tetrofosmin (t3) {yields}{yields} implies {sup 99m}Tc-furifosmin (t3), showing a significant increase in deteriorating myocardium for all tracers but {sup 99m}Tc-furifosmin. Delayed elimination in deteriorating myocardium explains at least partly the redistribution phenomenon of {sup 201}Tl, and suggests a similar phenomenon for {sup 99m}Tc-MIBI and {sup 99m}Tc-tetrofosmin.

  15. Determination of 99Mo in 99mTc eluates used in nuclear medicine centers in Rio de Janeiro

    International Nuclear Information System (INIS)

    Ribeiro, Bianca da S.; Souza, Raphael S.S.; Lucena, Eder A.; Dantas, Ana Leticia A.; Dantas, Bernardo M.

    2009-01-01

    99m Tc is used in nuclear medicine for image diagnoses with SPECT. It is obtained from the elution of molybdenum-99/technetium-99m ( 99 Mo/ 99m Tc) generators. During the elution, 99 Mo can detach from the column, passing through the filter and mixing in the solution of pertechnetate eluate and becoming a radionuclidic impurity. The presence of molybdenum in the radiopharmaceutical solution imparts an unnecessary radiation dose to the patient, since its half-life is relatively long (66 hours) and it emits beta particles and high-energy photons of (740 keV). A parameter that indicates the quality of the eluates is the radionuclidic purity, the MBT (molybdenum break through), defined as the ratio between 99 Mo and 99m Tc activities in the eluate. The American and the European Pharmacopoeias restrict 99 Mo content to respectively 0.015% and 0.1% activity ratio 99 Mo/ 99m Tc at the time of the administration to the patient. In Brazil, this parameter is not controlled by official regulations. The objective of this work is to determine the presence of 99 Mo in the eluates used in nuclear medicine centers (NMC). The activity measurements of 99 Mo were performed with a NaI(Tl)8''x4'' scintillation detector installed in the IRD whole body counter. The activity of 99m Tc was measured in the NMC where the eluates were collected and, using the established calculations, it was determined the activity ratio 99 Mo/ 99m Tc. The eluate samples were kindly supplied by the participating NMC of Rio de Janeiro. All measurements indicated the presence of 99 Mo. It is concluded that the technique is sensitive to detect 99 Mo in 99m Tc eluates and permits to verify the quality of the generators used in NMC evaluated in this study. (author)

  16. Influence of the electrolyte in the fixation of 99 Mo in hydroxyapatite as matrix of the 99 Mo/ 99m Tc generator

    International Nuclear Information System (INIS)

    Vazquez G, S.; Badillo A, V.E.; Monroy G, F.

    2005-01-01

    The more used isotope at the moment in the services of nuclear medicine in the world is the technetium-99m. The 99m Tc emitts gamma rays of 141 keV and it semi disintegration period is of six hours, given it short half life, to produce it is necessary to order generators that are systems that allow to separate periodically at the 99m Tc of the 99 Mo by means of chromatographic techniques. In this work it is sought to evaluate the use of the hydroxyapatite, to separate molybdates 99 MoO 4 2 of pertechnetates 99m TcO 4 - and to be able to determine if it is feasible their use for to build generators of 99m Tc. With this purpose preliminary tests to know the likeness of the hydroxyapatite for the molybdates in function of the pH value, in different solutions were carried out: one of NaCl 0.9%, NaCl 2% and CaCl 2 0.01 M. The obtained results in a NaCl 0.9% solution and at to 2% to different pH values of the solution, shows that the fixation of the molybdate ions (MoO 4 -2 ) it is worthless to basic pH values of (9-11), as long as in solution of CaCI 2 0.01 M show a considerable retention of molybdate ions. (Author)

  17. Utility of the Static-99 and Static-99R With Latino Sex Offenders.

    Science.gov (United States)

    Leguízamo, Alejandro; Lee, Seung C; Jeglic, Elizabeth L; Calkins, Cynthia

    2017-12-01

    The predictive validity of the Static-99 measures with ethnic minorities in the United States has only recently been assessed with mixed results. We assessed the predictive validity of the Static-99 and Static-99R with a sample of Latino sex offenders ( N = 483) as well as with two subsamples (U.S.-born, including Puerto Rico, and non-U.S.-born). The overall sexual recidivism rate was very low (1.9%). Both the Static-99 measures were able to predict sexual recidivism for offenders born in the United States and Puerto Rico, but neither was effective in doing so for other Latino immigrants. Calibration analyses ( N = 303) of the Static-99R were consistent with the literature and provided support for the potential use of the measure with Latinos born in the United States and Puerto Rico. These findings and their implications are discussed as they pertain to the assessment of Latino sex offenders.

  18. Photo-production of (99)Mo/(99m)Tc with electron linear accelerator beam.

    Science.gov (United States)

    Avagyan, R; Avetisyan, A; Kerobyan, I; Dallakyan, R

    2014-09-01

    We report on the development of a relatively new method for the production of (99)Mo/(99m)Tc. The method involves the irradiation of natural molybdenum using high-intensity bremsstrahlung photons from the electron beam of the LUE50 linear electron accelerator located at the Yerevan Physics Institute (YerPhi). The production method has been developed and shown to be successful. The linear electron accelerator at YerPhi was upgraded to allow for significant increases of the beam intensity and spatial density. The LUE50 was also instrumented by a remote control system for ease of operation. We have developed and tested the (99m)Tc extraction from the irradiation of natural MoO3. This paper reports on the optimal conditions of our method of (99)Mo production. We show the success of this method with the production and separation of the first usable amounts of (99m)Tc. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Performance tests on new chromatographic material for 99Mo-99mTc generators

    International Nuclear Information System (INIS)

    Sombrito, Elvira Z.; Bulos, Adelina D.M.

    2004-01-01

    Technetium-99m continues to be the main workhorse of nuclear medicine in the Philippines. Almost 13TBq of 99m Tc was imported to the country in 2002 supplied as 99m Tc- 99 Mo generators. These generators make use of fission molybdenum adsorbed onto an alumina column. Problems associated with the alumina chromatographic generators arise due to safety and economic issues that would be remedied by gel-type generators using low specific activity reactor-produced molybdenum-99 adsorbed on a high capacity gel column material. The Philippine Nuclear Research Institute (PNRI) exerted efforts in this direction by developing a gel-type column, which showed satisfactory molybdenum adsorptive capacity. Likewise, Kaken Co. in Japan in cooperation with Japan Atomic Energy Research Institute (JAERI) developed a dried form of a gel-type polyzirconium compound (PZC). It is a ready-to-use high molybdenum capacity column material for adsorbing reactor-produced molybedum-99. The performance of this material is being tested under the framework of the FNCA project on Research Reactor Utilization. Performance tests on four batches of PZC were performed using fission molybdenum eluted from a 99 Mo- 99m Tc generator. A total of 3.3 GBq 99 Mo was extracted from an alumina column of a commercial generator and mixed with carrier molybdenum solution. About 0.67 GBq was loaded into each of the 12 x 90 mm column. One batch was prepared and distributed in 1999 and tests showed very poor elution yield of 30%. Three recent batches of PZC (2002) gave elution yields of 71% (Range of 69-75). The adsorptive capacity is 99% with about 4% desorption rate. Elution volume is at 5-6 ml. Daily elution for five days gave from 1.6 to 5.5% variability. The tests were performed all at the same time and a trend of improving elution yield and consistency of daily elution yield was observed with the time of testing nearer to the sample preparation date. X-ray diffraction analysis showed an amorphous structure for

  20. 22 CFR 99.3 - [Reserved

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false [Reserved] 99.3 Section 99.3 Foreign Relations DEPARTMENT OF STATE LEGAL AND RELATED SERVICES REPORTING ON CONVENTION AND NON-CONVENTION ADOPTIONS OF EMIGRATING CHILDREN § 99.3 [Reserved] ...

  1. Threshold oxygen levels in Na(I) for the formation of NaCrO 2(s) on 18-8 stainless steels from accurate thermodynamic measurements

    Science.gov (United States)

    Sreedharan, O. M.; Madan, B. S.; Gnanamoorthy, J. B.

    1983-12-01

    The compound NaCrO 2(s) is an important corrosion product in sodium-cooled LMFBRs. The standard Gibbs energy of formation of NaCrO 2(s) is required for the computation of threshold oxygen levels in Na(1) for the formation of NaCrO 2(s) on 18-8 stainless steels. For this purpose the emf of the galvanic cell: Pt, NaCrO 2, Cr 2O 3, Na 2CrO 4/15 YSZ/O 2 ( P O 2 = 0.21 atm, air), Pt was measured over 784-1012 K to be: (E±4.4)(mV) = 483.67-0.34155 T(K). From this, the standard Gibbs energy of formation of NaCrO 2(s) from the elements ( ΔG f,T0) and from the oxides ( ΔG f,OX,T0) was calculated to be: [ΔG f,T0(NaCrO 2, s)±1.86] (kJ/mol) =-869.98 + 0.18575 T(K) , [ΔG f,OX,T0(NaCr0 2, s)±4.8] (kJ/mol) = -104.25-0.00856 T(K) . The molar heat capacity, C P0, of NaCrO 2(s) was measured by DSC to be (350-600 K): C P0(NaCrO 2, s) (J/K mol) = 27.15 + 0.1247 T (K) , From these data, values of -99.3 kJ/mol and 91.6 J/K mol were computed for ΔH f,2980 and S 2980 of NaCrO 2(s). The internal consistency was checked with the use of enthalpy data on Na 2CrO 4(s). From the standard Gibbs energy of formation of NaCrO 2(s) the equation logC 0(wppm) = 3.9905-3147.6 T(K) was derived, where C 0 is the threshold oxygen level for the formation of NaCrO 2(s) on 18-8 stainless steels.

  2. Nondestructive Examination Of Plutonium-Bearing Material Containers

    International Nuclear Information System (INIS)

    Yerger, L.; Mcclard, J.; Traver, L.; Grim, T.

    2010-01-01

    The first nondestructive examination (NDE) of 3013-type containers as part of the Department of Energy's (DOE's) Integrated Surveillance Program (ISP) was performed in February, 2005. Since that date 280 NDE surveillances on 255 containers have been conducted. These containers were packaged with plutonium-bearing materials at multiple DOE sites. The NDE surveillances were conducted at Hanford, Lawrence Livermore National Laboratory (LLNL), and Savannah River Site (SRS). These NDEs consisted of visual inspection, mass verification, radiological surveys, prompt gamma analysis, and radiography. The primary purpose of performing NDE surveillances is to determine if there has been a significant pressure buildup inside the inner 3013 container. This is done by measuring the lid deflection of the inner 3013 container using radiography images. These lid deflection measurements are converted to pressure measurements to determine if a container has a pressure of a 100 psig or greater. Making this determination is required by Surveillance and Monitoring Plan (S and MP). All 3013 containers are designed to withstand at least 699 psig as specified by DOE-STD-3013. To date, all containers evaluated have pressures under 50 psig. In addition, the radiography is useful in evaluating the contents of the 3013 container as well as determining the condition of the walls of the inner 3013 container and the convenience containers. The radiography has shown no signs of degradation of any container, but has revealed two packaging anomalies. Quantitative pressure measurements based on lid deflections, which give more information than the 'less than or greater than 100 psig' (pass/fail) data are also available for many containers. Statistical analyses of the pass/fail data combined with analysis of the quantitative data show that it is extremely unlikely that any container in the population of 3013 containers considered in this study (e.g., containers packaged according to the DOE-STD-3013

  3. An exploratory study on 99mTc-RGD-BBN peptide scintimammography in the assessment of breast malignant lesions compared to 99mTc-3P4-RGD2.

    Directory of Open Access Journals (Sweden)

    Qianqian Chen

    Full Text Available This study aimed to explore the diagnostic performance of single photon emission computed tomography / computerized tomography (SPECT/CT using a new radiotracer 99mTc-RGD-BBN for breast malignant tumor compared with 99mTc-3P4-RGD2.6 female patients with breast malignant tumors diagnosed by fine needle aspiration cytology biopsy (FNAB who were scheduled to undergo surgery were included in the study. 99mTc-3P4-RGD2 and 99mTc-RGD-BBN were performed with single photon emission computed tomography (SPECT at 1 hour after intravenous injection of 299 ± 30 MBq and 293 ± 32 MBq of radiotracers respectively at separate day. The results were evaluated by the Tumor to non-Tumor ratios (T/NT. 99mTc-RGD-BBN and 99mTc-3P4-RGD2 SPECT/CT images were interpreted independently by 3 experienced nuclear medicine physicians using a 3-point scale system. All of the samples were analyzed immunohistochemically to evaluate the integrin αvβ3 and gastrin-releasing peptide receptor (GRPR expression. The safety, biodistribution and radiation dosimetry of 99mTc-RGD-BBN were also evaluated in the healthy volunteers.No serious adverse events were reported in any of the patients during the study. The effective radiation dose entirely conformed to the relevant standards. A total of 6 palpable malignant lesions were detected using 99mTc-RGD-BBN SPECT/CT with clear uptake. All malignant lesions were also detected using 99mTc-3P4-RGD2 SPECT/CT. The results showed that five malignant lesions were with clear uptake and the other one with barely an uptake. 4 malignant cases were found with both αvβ3 and GRPR expression, 1 case with only GRPR positive expression (integrin αvβ3 negative and 1 case with only integrin αvβ3 positive expression (GRPR negative.99mTc-RGD-BBN is a safe agent for detecting breast cancer. 99mTc-RGD-BBN may have the potential to make up for the deficiency of 99mTc-3P4-RGD2 in the detection of breast cancer with only GRPR positive expression (integrin

  4. Assessment of 99Tc releases to the atmosphere: a plea for applied research

    International Nuclear Information System (INIS)

    Till, J.E.; Hoffman, F.O.; Dunning, D.E. Jr.

    1978-06-01

    Recent experimental data suggest that the concentration factor for uptake of 99 Tc by vegetation from soils may be two to three orders of magnitude higher than the 0.25 value currently being used in radiological assessments. Following a survey of the literature, a concentration factor of 50 was applied to evaluate the dose from a 1.0 Ci/year release to the atmosphere by a hypothetical uranium enrichment facility. Doses to the GI tract and thyroid of an adult living 1600 m from the facility were 18 millirems and 80 millirems, respectively. These doses are delivered entirely through transport of 99 Tc through food chain pathways. This assessment indicates a potential for 99 Tc exposures to exceed recently proposed standards of the U.S. Environmental Protection Agency in 40 CFR 190. The previously assumed concentration factor of 0.25 would have produced corresponding doses of 0.13 millirem to the GI tract and 0.57 millirem to the thyroid. The results of this analysis demonstrate the need for additional research on the environmental behavior and dosimetry of 99 Tc. In particular, data are needed to elucidate the retention of 99 Tc in soils and the uptake of 99 Tc by edible vegetation in field studies of chronic exposure conditions. Data on the uptake and retention of 99 Tc in humans are also necessary to improve the reliability of dose conversion factors for specific organs and various age groups

  5. Permanent Closure of MFC Biodiesel Underground Storage Tank 99ANL00013

    Energy Technology Data Exchange (ETDEWEB)

    Kerry L. Nisson

    2012-10-01

    This closure package documents the site assessment and permanent closure of the Materials and Fuels Complex biodiesel underground storage tank 99ANL00013 in accordance with the regulatory requirements established in 40 CFR 280.71, “Technical Standards and Corrective Action Requirements for Owners and Operators of Underground Storage Tanks: Out-of-Service UST Systems and Closure.”

  6. Technetium-99 ({sup 99}Tc) in annual growth segments of knotted wrack (Ascophyllum nodosum)

    Energy Technology Data Exchange (ETDEWEB)

    Heldal, Hilde Elise, E-mail: Hilde.Heldal@imr.no [Institute of Marine Research (IMR), PO Box 1870 Nordnes, N-5817 Bergen (Norway); Sjotun, Kjersti, E-mail: Kjersti.Sjotun@bio.uib.no [University of Bergen (UoB), Department of Biology, PO Box 7803, N-5020 Bergen (Norway)

    2010-10-15

    The distribution of technetium-99 ({sup 99}Tc) in annual growth segments of the brown seaweed Ascophyllum nodosum (Fucales, Phaeophyceae) from the southwestern coast of Norway is examined in samples collected from January to November 2006. A twenty-fold increase in the {sup 99}Tc-concentration from the youngest to the oldest growth segments was found. The concentrations ranged from 42 to 98 Bq/kg dry weight (d.w.) and from 964 to 1000 Bq/kg d.w. in growth segments formed in 2006 and 1996, respectively. In addition, a seasonal variation in the {sup 99}Tc concentration was observed in the actively growing 2006-segments: concentrations decreased from 98 Bq/kg d.w. in April to 54 Bq/kg d.w. in June; there was a further reduction from June to August (42 Bq/kg d.w.); and, finally there was an increase from August to November (93 Bq/kg d.w.). In most of the segments formed between 2000 and 2005, there was a tendency of slightly decreasing {sup 99}Tc-concentrations between June and November but this pattern was not observed for the older growth segments. In order to find an explanation for the non-homogenous distribution of {sup 99}Tc within thalli of A. nodosum, different hypotheses are discussed. Uptake and elimination of {sup 99}Tc appears to be most pronounced in the actively growing segments. To date, such non-homogenous distribution of {sup 99}Tc within thalli of A. nodosum has not been taken into consideration, neither in connection with sample collection nor analysis. This paper shows that special protocols must be followed if A. nodosum is going to be used as a bioindicator for {sup 99}Tc in the marine environment. A sampling strategy is proposed.

  7. Standardization of the cumulative absolute velocity

    International Nuclear Information System (INIS)

    O'Hara, T.F.; Jacobson, J.P.

    1991-12-01

    EPRI NP-5930, ''A Criterion for Determining Exceedance of the Operating Basis Earthquake,'' was published in July 1988. As defined in that report, the Operating Basis Earthquake (OBE) is exceeded when both a response spectrum parameter and a second damage parameter, referred to as the Cumulative Absolute Velocity (CAV), are exceeded. In the review process of the above report, it was noted that the calculation of CAV could be confounded by time history records of long duration containing low (nondamaging) acceleration. Therefore, it is necessary to standardize the method of calculating CAV to account for record length. This standardized methodology allows consistent comparisons between future CAV calculations and the adjusted CAV threshold value based upon applying the standardized methodology to the data set presented in EPRI NP-5930. The recommended method to standardize the CAV calculation is to window its calculation on a second-by-second basis for a given time history. If the absolute acceleration exceeds 0.025g at any time during each one second interval, the earthquake records used in EPRI NP-5930 have been reanalyzed and the adjusted threshold of damage for CAV was found to be 0.16g-set

  8. Low-activity 124I-PET/low-dose CT versus 99mTc-pertechnetate planar scintigraphy or 99mTc-pertechnetate single-photon emission computed tomography of the thyroid: a pilot comparison.

    Science.gov (United States)

    Darr, Andreas M; Opfermann, Thomas; Niksch, Tobias; Driesch, Dominik; Marlowe, Robert J; Freesmeyer, Martin

    2013-10-01

    The standard thyroid functional imaging method, 99mTc-pertechnetate (99mTc-PT) planar scintigraphy, has technical drawbacks decreasing its sensitivity in detecting nodules or anatomical pathology. 124I-PET, lacking these disadvantages and allowing simultaneous CT, may have greater sensitivity for these purposes. We performed a blinded pilot comparison of 124I-PET(/CT) versus 99mTc-PT planar scintigraphy or its cross-sectional enhancement, 99mTc-PT single-photon emission CT (SPECT), in characterizing the thyroid gland with benign disease. Twenty-one consecutive adults with goiter underwent low-activity (1 MBq/0.027 mCi) 124I-PET/low-dose (30 mAs) CT, 99mTc-PT planar scintigraphy, and 99mTc-PT-SPECT. Endpoints included the numbers of “hot spots” with/without central photopenia and “cold spots” detected, the proportion of these lesions with morphological correlates, the mean volume and diameter of visualized nodules, and the number of cases of lobus pyramidalis or retrosternal thyroid tissue identified. 124I-PET detected significantly more “hot spots” with/without central photopenia (P < 0.001), significantly more nodules (P < 0.001), and more “cold spots” than did 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT, including all lesions seen on the 99mTc-PT modalities. Ultrasonographic correlates were found for all nodules visualized on all 3 modalities and 92.5% of nodules seen only on 124I-PET. Nodules discernible only on 124I-PET had significantly smaller mean volume or diameter (P < 0.001) than did those visualized on 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT. 124I-PET(/CT) identified significantly more patients with a lobus pyramidalis (P < 0.001) or retrosternal thyroid tissue (P < 0.05). 124I-PET(/CT) may provide superior imaging of benign thyroid disease compared to planar or cross-sectional 99mTc-PT scintigraphy.

  9. Preoperative radiological diagnosis by 99mTc·MIBI-99mTc subtraction scintigraphy for primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Inouye, Takahiro; Tomita, Toshiki; Shinden, Seiichi; Takagi, Hitoshi; Kano, Shigeru.

    1996-01-01

    Preoperative radiological diagnosis constitutes the most important factor for the surgical treatment of hyperparathyroidism. In this regard, MRI is useful for detecting the abnormal parathyroid, but it is often difficult to localize it using MRI only. It is thus necessary to combine this procedure with excellent subtraction scintigraphy. We performed both 201 Tl- 99m Tc and 99m Tc·MIBI- 99m Tc subtraction scintigraphy in seven patients with primary hyperparathyroidism and compared them the radiological results. Five patients presented parathyroid adenomas and the rest hypertrophy of the parathyroid. We could detect the abnormal parathyroid in four patients (57.1%) by 201 Tl- 99m Tc subtraction scintigraphy and in six patients (85.7%) by 99m Tc·MIBI- 99m Tc subtraction scintigraphy. We therefore believe that 99m Tc·MIBI- 99m Tc subtraction scintigraphy will become an essential examination for primary hyperparathyroidism rather than the presently employed 201 Tl- 99m Tc subtraction scintigraphy. (author)

  10. Problems in clinical practice of domestic supply of 99Mo/99mTc. The direction and problem of stable supply chain of 99Mo in Japan

    International Nuclear Information System (INIS)

    Inoue, Tomio

    2013-01-01

    The shortage of supply of 99 Mo caused by trouble of old nuclear reactors in Canada and Europe caused international problem in the field of nuclear medicine, which has not been completely resolved yet. Because all of 99 Mo/ 99m Tc generator in Japan has been imported, Japan Atomic Energy Commission (JAEC) suggested the necessity of establishment of stable supply chain of 99 Mo ( 99 Mo/ 99m Tc generator). According this suggestion, an ad hoc committee appointed to consider the stable supply chain, which consisted of persons concerned with industry, academic society, Japan Isotope Association, Ministry of Education, Culture, Sports, Science, and Technology-Japan (MEXT), Ministry of Health, Labour and Welfare (MHLW), Japan Atomic Energy Agency (JAEA), National Institute of Radiological Science (NIRS) et al., evaluated and compared several ways of production and purification of 99 Mo from the view point of technological maturity, regulation compatibility, economic suitability, and stability for supply. In this review, the summary of the committee report is introduced. For short term strategy, we need to keep the variable import routes for 99 Mo. As a mid-term goal, we need to establish the supply chain inside Japan as a conclusion of the committee report but it seems to be not easy for utility of nuclear reactor after nuclear accident of Fukushima Daiichi Nuclear Power Plant. The development of the method for 99 Mo/ 99m Tc production using accelerator is also expected for the establishment of stable supply chain. (author)

  11. Radiation hormesis and the linear-no-threshold assumption

    CERN Document Server

    Sanders, Charles L

    2009-01-01

    Current radiation protection standards are based upon the application of the linear no-threshold (LNT) assumption, which considers that even very low doses of ionizing radiation can cause cancer. The radiation hormesis hypothesis, by contrast, proposes that low-dose ionizing radiation is beneficial. In this book, the author examines all facets of radiation hormesis in detail, including the history of the concept and mechanisms, and presents comprehensive, up-to-date reviews for major cancer types. It is explained how low-dose radiation can in fact decrease all-cause and all-cancer mortality an

  12. Threshold behavior in electron-atom scattering

    International Nuclear Information System (INIS)

    Sadeghpour, H.R.; Greene, C.H.

    1996-01-01

    Ever since the classic work of Wannier in 1953, the process of treating two threshold electrons in the continuum of a positively charged ion has been an active field of study. The authors have developed a treatment motivated by the physics below the double ionization threshold. By modeling the double ionization as a series of Landau-Zener transitions, they obtain an analytical formulation of the absolute threshold probability which has a leading power law behavior, akin to Wannier's law. Some of the noteworthy aspects of this derivation are that the derivation can be conveniently continued below threshold giving rise to a open-quotes cuspclose quotes at threshold, and that on both sides of the threshold, absolute values of the cross sections are obtained

  13. Heat-Related Deaths in Hot Cities: Estimates of Human Tolerance to High Temperature Thresholds

    Directory of Open Access Journals (Sweden)

    Sharon L. Harlan

    2014-03-01

    Full Text Available In this study we characterized the relationship between temperature and mortality in central Arizona desert cities that have an extremely hot climate. Relationships between daily maximum apparent temperature (ATmax and mortality for eight condition-specific causes and all-cause deaths were modeled for all residents and separately for males and females ages <65 and ≥65 during the months May–October for years 2000–2008. The most robust relationship was between ATmax on day of death and mortality from direct exposure to high environmental heat. For this condition-specific cause of death, the heat thresholds in all gender and age groups (ATmax = 90–97 °F; 32.2‒36.1 °C were below local median seasonal temperatures in the study period (ATmax = 99.5 °F; 37.5 °C. Heat threshold was defined as ATmax at which the mortality ratio begins an exponential upward trend. Thresholds were identified in younger and older females for cardiac disease/stroke mortality (ATmax = 106 and 108 °F; 41.1 and 42.2 °C with a one-day lag. Thresholds were also identified for mortality from respiratory diseases in older people (ATmax = 109 °F; 42.8 °C and for all-cause mortality in females (ATmax = 107 °F; 41.7 °C and males <65 years (ATmax = 102 °F; 38.9 °C. Heat-related mortality in a region that has already made some adaptations to predictable periods of extremely high temperatures suggests that more extensive and targeted heat-adaptation plans for climate change are needed in cities worldwide.

  14. 14 CFR 99.12 - [Reserved

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false [Reserved] 99.12 Section 99.12 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SECURITY CONTROL OF AIR TRAFFIC General § 99.12 [Reserved] ...

  15. Reliability and validity of a new fingertip-shaped pressure algometer for assessing pressure pain thresholds in the temporomandibular joint and masticatory muscles.

    Science.gov (United States)

    Bernhardt, Olaf; Schiffman, Eric L; Look, John O

    2007-01-01

    To test in vitro and in vivo the reliability and accuracy of a new algometer, the pressure algometer for palpation (PAP), for measuring pressure pain thresholds (PPTs) and to compare its features with those of a commercially available pressure algometer. For in vitro accuracy testing, 6 repeated measurements were made at 8 defined test weights from 0.5 to 5 lb. In vivo validity testing compared the PAP to a standard instrument, the hand-held Somedic algometer, at 16 sites including the masticatory muscles, the temporomandibular joints, and the frontalis (as the control site) in 15 temporomandibular disorder (TMD) cases and 15 controls. Intraexaminer reliability was also assessed for both algometers. In vitro reliability was high, with coefficients of variation of test weights at r = .99 (P algometer. PPT values correlated moderately between the 2 devices (r ranged from 0.38 to 0.66; P algometers (P algometer showed high reliability. Concurrent validity was demonstrated by statistically significant correlations between the devices. Both showed equally high capacity for differentiating TMD cases from controls. The PAP yielded significantly higher PPTs than the Somedic algometer.

  16. In vitro evaluation of canine leukocytes radiolabeled in whole blood with 99mTc stannous colloid

    International Nuclear Information System (INIS)

    Abushhiwa, Mohamed H.; Salehi, Nouria S.; Whitton, Robert C.; Charles, Jennifer A.; Finnin, Peter J.; Lording, Peter M.; Caple, Ivan W.; Parry, Bruce W.

    2008-01-01

    Introduction: Technetium-99m stannous colloid ( 99m TcSnC)-labeled leukocytes are used to investigate a variety of inflammatory diseases in human medicine. The present study investigates the in vitro behavior of canine leukocytes labeled in whole blood with 99m TcSnC. Methods: Blood samples from 10 healthy dogs were labeled with 99m TcSnC using a standard procedure. The distribution of radioactivity among blood components (plasma, leukocyte layers and erythrocytes) was measured following separation of the radiolabeled samples across Histopaque density gradients. Phagocytic function of labeled and unlabeled leukocytes was estimated using zymosan particles. Labeling retention by leukocytes was determined at 1, 3, 4 and 7 h postlabeling. Results: The mean±standard error percentage of radioactivity associated with plasma, erythrocyte and leukocyte fractions was 2.0±0.21%, 55.5±0.60% and 42.5±0.54%, respectively (the last comprising 70.2±0.83% in polymorphonuclear leukocytes and 29.8±0.83% in mononuclear leukocytes). Labeled canine leukocytes had a phagocytic activity of 91.3±0.28% (control, 91.7±0.26%). The radiolabeled canine leukocytes retained 94.1±0.30% of radioactivity at 7 h postlabeling. Conclusions: Radiolabeling of canine leukocytes in whole blood with 99m TcSnC has minor adverse effect on their phagocytic function. The radiolabeled canine leukocytes retained a large percentage of radioactivity for at least 7 h postlabeling

  17. The risk analysis used to manufacture 99Mo/99mTc generators

    International Nuclear Information System (INIS)

    Fano Machín, Yoiz; Alberti Ramírez, Alejandro; Gamboa Marrero, Regla; Suárez Beyríes, Karina; Cruz Morales, Amed

    2016-01-01

    In this work the steps to be followed for the risk analysis in the process of production of 99 Mo / 99m Tc generators in CENTIS, using the methodology of analysis of modes and effects of failures are collected. The analysis of the type and probability of occurrence of the failures in the process, as well as the impact on the quality of the same and the probability of detection of such failures, were used for the use of techniques used in quality assurance such as: storm Ideas and cause-effect diagram. Scales were established for the determination of severity, probability of occurrence, probability of detection and calculation of the number of risk probabilities. The guidelines were laid down for the future application of this technique, which will establish a decision-making process regarding the risks associated with the production process of 99 Mo / 99m Tc generators. (author)

  18. Preparation of hypoxic imaging agents 99Tcm-MNLS and 99Tcm-MLS and their biodistribution in mice

    International Nuclear Information System (INIS)

    Zha Zhihao; Wang Jianjun; Zhu Lin

    2009-01-01

    To develop 99 Tc m labeled hypoxic agents,two phosphate-based chelating agents were coupled to metronidazole, 2- (2-methyl-5-nitro-1H-imidazol-1-yl) ethyl dihydrogen phosphate (MNLS) and its analog 2- (2-methyl-1H-imidazol-1-yl) ethyl dihydrogen phosphate (MLS) were synthesized based on the mechanism of prodrug. Labeling yield of these 99 Tc m complexes were more than 90% as proved by TLC. Paper electrophoresis showed that these complexes were neutral. Biodistribution of these complexes in tumor-bearing mice showed that the uptake of 99 Tc m -MNLS (120 min, 2.99 ± 0.25 ID%/g) in tumor was higher than that of 99 Tc m -HL91 (120 min, 0.93 ± 0.13 ID%/g) and 99 Tc m -MLS (120 min, 1.61 ± 0.13 ID%/g), and the uptake ratio of tumor to muscle and tumor to liver of 99 Tc m -MNLS (120 min, 5.90, 1.03) were higher than that of 99 Tc m -HL91 (120 min, 3.59, 0.17) and 99 Tc m -MLS (120 min, 5.40, 0.13). The higher tumor uptake for 99 Tc m -MNLS than 99 Tc m -MLS suggested that nitroimidazole was a key group for tumor accumulation. 99 Tc m -MNLS had higher tumor uptake and lower liver uptake, which had the potential for tumor imaging and was worth of further vestigation. (authors)

  19. Double Photoionization Near Threshold

    Science.gov (United States)

    Wehlitz, Ralf

    2007-01-01

    The threshold region of the double-photoionization cross section is of particular interest because both ejected electrons move slowly in the Coulomb field of the residual ion. Near threshold both electrons have time to interact with each other and with the residual ion. Also, different theoretical models compete to describe the double-photoionization cross section in the threshold region. We have investigated that cross section for lithium and beryllium and have analyzed our data with respect to the latest results in the Coulomb-dipole theory. We find that our data support the idea of a Coulomb-dipole interaction.

  20. 14 CFR 99.41 - General.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false General. 99.41 Section 99.41 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SECURITY CONTROL OF AIR TRAFFIC Designated Air Defense Identification Zones § 99...

  1. 14 CFR 99.3 - Definitions.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Definitions. 99.3 Section 99.3 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SECURITY CONTROL OF AIR TRAFFIC General § 99.3 Definitions. Aeronautical facility...

  2. A simple and sensitive separation technique of 99Mo and 99mTc from their equilibrium mixture

    International Nuclear Information System (INIS)

    Swadesh Mandal; Ajoy Mandal

    2014-01-01

    The present work describes a simple and inexpensive separation method of 99 Mo from the equilibrium mixture. The liquid-liquid extraction technique has been employed to separate 99 Mo and 99m Tc using triisooctylamine (TIOA). The 99 Mo and 99m Tc were quantitatively separated out in 2 M TIOA with tripled distilled water; 99m Tc was back extracted from TIOA organic phase to aqueous phase by 0.1 M DTPA. The species information or indirect speciation of molybdenum was also established by the extraction profile of the molybdenum. (author)

  3. Setting ambient air quality standards for particulate matter

    International Nuclear Information System (INIS)

    McClellan, Roger O.

    2002-01-01

    Ambient air particulate matter (PM), unspecified as to chemical composition, is of concern because of its health effects. Air quality standards for PM have been established in many countries. The earliest standards were based on threshold models and use of a margin of safety. Initially, standards were based on the mass of total suspended material. In the 1980s a shift to a size-specific standard, PM 10 , began. PM 10 is the fraction of PM captured with 50% efficiency at 10 μm and greater efficiency at smaller sizes. In the late 1990s, standards were proposed for PM 2.5 , which is captured with 50% efficiency at 2.5 μm. The standards for PM are based almost exclusively on human epidemiological data, with laboratory animal and in vitro data used in a supporting role. During the 1990s, new statistical tools began to be used and demonstrated an association between increased PM and an increase in cardiorespiratory morbidity and mortality. The analyses are complicated by the effects of other pollutants such as ozone. Effects have been observed down to 10-20 μg of PM 10 per cubic meter, levels equal to or below background in many parts of the world. In many studies there has been no evidence of a threshold. In the absence of a threshold, a critical issue becomes how to determine how low is low enough? This paper reviews the current literature on PM health effects and suggests research avenues that may yield data which, combined with public policy considerations, may be able to address the issue of 'how low is low enough?'

  4. A new approach for manufacturing and processing targets to produce 99mTc with cyclotrons

    Science.gov (United States)

    Matei, L.; McRae, G.; Galea, R.; Niculae, D.; Craciun, L.; Leonte, R.; Surette, G.; Langille, S.; Louis, C. St.; Gelbart, W.; Abeysekera, B.; Johnson, R. R.

    2017-06-01

    The most important radioisotope for nuclear medicine is 99mTc. After the supply crisis of 99Mo starting in 2008, the availability of 99mTc became a worldwide concern. Alternative methods for producing the medical imaging isotope 99mTc are actively being developed around the world. The reaction 100Mo(p, 2n)99mTc provides a direct route that can be incorporated into routine production in nuclear medicine centers that possess medical cyclotrons for production of other isotopes, such as those used for Positron Emission Tomography. This paper describes a new approach for manufacturing targets for the (p, 2n) nuclear reaction on 100Mo and the foundation for the subsequent commercial separation and purification of the 99mTc produced. Two designs of targets are presented. The targets used to produce 99mTc are subject to a number of operational constraints.They must withstand the temperatures generated by the irradiation, accommodate temperature gradients from cooling system of the target, must be resilient and must be easily post-processed to separate the 99mTc. After irradiation, the separation of Tc from Mo was carried out using an innovative two-step approach. The process described in this paper can be automated with modules that easily fit in standard production hot cells found in nuclear medicine facilities.

  5. Social Moderation, Assessment and Assuring Standards for Accounting Graduates

    Science.gov (United States)

    Watty, Kim; Freeman, Mark; Howieson, Bryan; Hancock, Phil; O'Connell, Brendan; de Lange, Paul; Abraham, Anne

    2014-01-01

    Evidencing student achievement of standards is a growing imperative worldwide. Key stakeholders (including current and prospective students, government, regulators and employers) want confidence that threshold learning standards in an accounting degree have been assured. Australia's new higher education regulatory environment requires that student…

  6. Neodymium: YAG laser damage threshold. A comparison of injection-molded and lathe-cut polymethylmethacrylate intraocular lenses.

    Science.gov (United States)

    Wilson, S E; Brubaker, R F

    1987-01-01

    The possibility that injection-molded intraocular lenses (IOLs) with imperfections called iridescent clefts could have a decreased threshold to neodymium: YAG (Nd:YAG) laser-induced damage was investigated. Thresholds for Nd:YAG laser-induced damage were determined for injection-molded and lathe-cut polymethylmethacrylate lenses. When aimed at a membrane in contact with a posterior convex surface, the average thresholds were 0.96 +/- 0.18 mJ (Standard deviation [SD]) and 1.80 +/- 0.55 mJ, respectively. The difference was significant at P = 0.001. When injection-molding polymethylmethacrylate was used to make lathe-cut IOLs, very few iridescent clefts were present, and the threshold to Nd:YAG laser-induced damage was 0.94 +/- 0.25 mJ. Iridescent clefts are therefore produced during the injection-molding process but they do not lower the threshold to Nd:YAG laser-induced damage. Rather, the reduced threshold in injection-molded lenses is most probably a result of the polymethylmethacrylate used in their manufacture. Clinically, iridescent clefts in a lens suggest that it has been manufactured by an injection-molding process and that Nd:YAG laser posterior capsulotomy must be performed at the lowest possible energy level to avoid damage.

  7. The separation of sup(99m)Tc from 99Mo through an aluminium oxide chromatographic columm

    International Nuclear Information System (INIS)

    Imoto, S.T.

    1980-01-01

    The separation of sup(99m)Tc from 99 Mo using the chromatographic method is studied. Alumina is used as adsorbent. The pH values for adsorption of carrier-free 99 Mo on columns filled with ordinary alumina and with that thermically treated at 1000 0 C for five hours, and the separation conditions of sup(99m)Tc using physiologic solution as eluent are determined. The sup(99m)Tc separation yields of both columns are compared and the quality of the products obtained by successive elutions for 10 days is analyzed. (Author) [pt

  8. Reproducibility indices applied to cervical pressure pain threshold measurements in healthy subjects.

    Science.gov (United States)

    Prushansky, Tamara; Dvir, Zeevi; Defrin-Assa, Ruth

    2004-01-01

    To apply various statistical indices for reproducibility analysis of pressure pain threshold measurements and to derive a preferred pressure pain threshold measurement protocol based on these indices. The pressure pain threshold of 3 pairs of right and left homologous cervical region sites were measured in 20 healthy subjects (10 women, 10 men) using a hand-held pressure algometer. Measurements took place on 2 occasions (test 1 and test 2) separated by a mean interval of 1 week. On each testing session, the site-related pressure pain thresholds were measured 3 times each according to 2 different protocols. Protocol A consisted of a repetitive order, namely 3 consecutive measurements at each site before proceeding to the next, whereas protocol B consisted of an alternate order in which 3 consecutive rounds of all individually tested sites took place. For test 1, protocol A was followed by protocol B with an hour interval. For test 2, the reverse order took place. The findings revealed no significant differences between the two protocols and indicated a significant rise (P test 1 to test 2 in both protocols. Absolute values (mean +/-SD) derived from the entire sample of pressure pain threshold sites ranged from 140 +/- 60 to 198.7 +/- 95 kPa (1.60 +/- 0.6 to 1.99 +/- 0.95 kg/cm, respectively). No significant gender or side differences were noted. Pearson r as well as the intraclass correlation coefficient revealed good to excellent reproducibility for both protocols and for all sites measured: r = 0.79-0.94 and intraclass correlation coefficient(3,3) = 0.85-0.96, respectively. To define site-specific cutoff values indicating change at the 95% confidence level, 1.96*SEM was calculated, and its values ranged from 31.6 to 58.2 kPa, which correspond to 16.8% to 32.8% of the absolute mean values. In addition, the limits of agreement, which depict the individual test-retest differences relative to their mean, indicated a heteroscedastic trend. The two protocols yielded

  9. Elimination of threshold singularities in the relation between on-shell and pole widths

    International Nuclear Information System (INIS)

    Kniehl, Bernd A.; Palisoc, Caesar P.; Sirlin, Alberto

    2002-01-01

    In a previous communication by two of us [B. A. Kniehl and A. Sirlin, Phys. Rev. Lett. 81, 1373 (1998)], the gauge-dependent deviations of the on-shell mass and total decay width from their gauge-independent pole counterparts were investigated at leading order for the Higgs boson of the standard model. In the case of the widths, the deviation was found to diverge at unphysical thresholds, m H =2√(ξ V )m V (V=W,Z), in the R ξ gauge. In this Brief Report, we demonstrate that these unphysical threshold singularities are properly eliminated if a recently proposed definition of wave-function renormalization for unstable particles is invoked

  10. Elimination of threshold singularities in the relation between on-shell and pole widths

    International Nuclear Information System (INIS)

    Kniehl, B.A.; Palisoc, C.P.; Sirlin, A.

    2002-05-01

    In a previous communication by two of us, Phys. Rev. Lett. 81, 1373 (1998), the gauge-dependent deviations of the on-shell mass and total decay width from their gauge-independent pole counterparts were investigated at leading order for the Higgs boson of the Standard Model. In the case of the widths, the deviation was found to diverge at unphysical thresholds, m H =2√(ξ V )m V (V=W,Z), in the R ξ gauge. In this Brief Report, we demonstrate that these unphysical threshold singularities are properly eliminated if a recently proposed definition of wave-function renormalization for unstable particles is invoked. (orig.)

  11. Elimination of Threshold Singularities in the Relation Between On-Shell and Pole Widths

    CERN Document Server

    Kniehl, Bernd A; Sirlin, A; Kniehl, Bernd A.; Palisoc, Caesar P.; Sirlin, Alberto

    2002-01-01

    In a previous communication by two of us, Phys. Rev. Lett. 81, 1373 (1998), the gauge-dependent deviations of the on-shell mass and total decay width from their gauge-independent pole counterparts were investigated at leading order for the Higgs boson of the Standard Model. In the case of the widths, the deviation was found to diverge at unphysical thresholds, m_H = 2 root{xi_V} m_V (V = W,Z), in the R_xi gauge. In this Brief Report, we demonstrate that these unphysical threshold singularities are properly eliminated if a recently proposed definition of wave-function renormalization for unstable particles is invoked.

  12. 45 CFR 99.25 - Evidence.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Evidence. 99.25 Section 99.25 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION PROCEDURE FOR HEARINGS FOR THE CHILD CARE AND DEVELOPMENT FUND Hearing Procedures § 99.25 Evidence. (a) Testimony. Testimony shall be given orally under...

  13. 22 CFR 99.1 - Definitions.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Definitions. 99.1 Section 99.1 Foreign Relations DEPARTMENT OF STATE LEGAL AND RELATED SERVICES REPORTING ON CONVENTION AND NON-CONVENTION ADOPTIONS OF EMIGRATING CHILDREN § 99.1 Definitions. As used in this part, the term: (a) Convention means...

  14. 45 CFR 99.23 - Discovery.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Discovery. 99.23 Section 99.23 Public Welfare... DEVELOPMENT FUND Hearing Procedures § 99.23 Discovery. The Department, the Lead Agency, and any individuals or groups recognized as parties shall have the right to conduct discovery (including depositions) against...

  15. {sup 99m}Tc generator preparation using (n, {gamma}){sup 99}Mo produced ex-natural molybdenum

    Energy Technology Data Exchange (ETDEWEB)

    Le, So Van [Nuclear Research Institute, Dalat (Viet Nam)

    2003-03-01

    Theoretical assessment on the chromatographic {sup 99m}Tc generator preparation using (n, {gamma}) {sup 99}Mo produced ex-natural molybdenum was carried out. The relationship between the neutron flux for MoO{sub 3} target activation, Mo-content or Mo adsorption capacity of column packing material, {sup 99m}Tc pertechnetate concentration and/or {sup 99m}Tc radioactivity of eluate was established. The reasonably lower limit of neutron flux of reactor and Molybdenum content of column packing material were found out to estimate the production of portable chromatographic generators available for nuclear medicine application. The concentration of {sup 99m}Tc pertechnetate eluate of low {sup 99m}Tc concentration using the column elution technique was also evaluate theoretically and conducted successfully in practice. Three options of {sup 99m}Tc generator using Titanium-Molybdate, Zirconium-Molybdate and Zirconium Oxide as generator column-packing materials were prepared and successfully put into use in nuclear medicine application. (author)

  16. The case for regime-based water quality standards

    Science.gov (United States)

    G.C. Poole; J.B. Dunham; D.M. Keenan; S.T. Sauter; D.A. McCullough; C. Mebane; J.C. Lockwood; D.A. Essig; M.P. Hicks; D.J. Sturdevant; E.J. Materna; S.A. Spalding; J. Risley; M. Deppman

    2004-01-01

    Conventional water quality standards have been successful in reducing the concentration of toxic substances in US waters. However, conventional standards are based on simple thresholds and are therefore poorly structured to address human-caused imbalances in dynamic, natural water quality parameters, such as nutrients, sediment, and temperature. A more applicable type...

  17. Performance tests on column materials for {sup 99}Mo-{sup 99m}Tc generator

    Energy Technology Data Exchange (ETDEWEB)

    Sombrito, E Z; Bulos, A D; Tangonan, M C [Chemistry Research Section, Atomic Research Div., Philippine Nuclear Research Inst., Quezon (Philippines)

    1998-10-01

    To meet the need of producing a {sup 99}Mo-{sup 99m}Tc generator, based on low specific activity reactor-produced {sup 99}Mo, different procedures for preparing zirconium molybdate gels were tested. Performance tests were done on molybdate gel columns prepared using the procedures developed by Vietnam and China, and recently, on a polyzirconium compound (PZC) prepared in Japan. The conditions for the batch drying of a large volume of the gel material were studied as well as the conditions in preparing a column to concentrate technetium-99m. The performance of PZC sample as column material for the generator was also evaluated. (author)

  18. Clinical comparison of technetium-99m-EC, technetium-99-m-MAG3 and Iodine-131-OIH in renal disorders

    International Nuclear Information System (INIS)

    Kabasakal, L.; Turoglu, T.; Oensel, C.

    1995-01-01

    Technetium-99m-ethylenedicysteine has recently been developed for renal function studies. The pharmacokinetics of 99m Tc-EC were studied by constant infusion technique and compared with 99m Tc-MAG3 and 131 I-OIH in 11 patients with various renal disorders. After giving a 7.4 MBq 131 I-OIH and 90-110 MBq 99m Tc-EC or 99m Tc-MAG3 bolus, a constant infusion (MBq/ml) 99m Tc--agent and 0.07 MBq/m 131 I-OIH was started. Sixteen blood and five urine samples were obtained over three hr. The renal clearance of 99m Tc-EC was higher than than of 99m Tc-MAG3. The 99m Tc-EC/OIH and 99m Tc-MAG3/OIH ratios were 0.75 ± 0.05 and 0.55 ± 0.10 (p=0.00087), respectively. The distribution volume of 99m Tc-EC was also higher than that of 99m Tc-MAG3 (15722 ± 4644 and 9509 ± 2788 ml/1.73m 2 , respectively; p=0.072). The 99m Tc-EC/OIH and 99m Tc-MAG/OIH distribution volume ratios were 1.03 ± 0.14 and 0.55 ± 0.10, respectively (p = 0.0003). The 60-min excretion values of 99m Tc-EC and 99m Tc-MAG3 were compared to that of OIH. The 99m Tc-EC/OIH and 99m Tc-MAG3/OIH excretion ratios were 0.96 ± 0.06 and 1.07 ± 0.10, respectively (p=0.162). The protein binding of 99m -EC and OIH were found to be 34% ±4 and 66% ±5, respectively (p 99m Tc-EC was negligible (3% ±1.2) in comparison to OIH (27% ±3; p 99m Tc-EC. This agent has good potential for renal function evaluation. 32 refs., 5 tabs

  19. MOS Current Mode Logic Near Threshold Circuits

    Directory of Open Access Journals (Sweden)

    Alexander Shapiro

    2014-06-01

    Full Text Available Near threshold circuits (NTC are an attractive and promising technology that provides significant power savings with some delay penalty. The combination of NTC technology with MOS current mode logic (MCML is examined in this work. By combining MCML with NTC, the constant power consumption of MCML is reduced to leakage power levels that can be tolerated in certain modern applications. Additionally, the speed of NTC is improved due to the high speed nature of MCML technology. A 14 nm Fin field effect transistor (FinFET technology is used to evaluate these combined circuit techniques. A 32-bit Kogge Stone adder is chosen as a demonstration vehicle for feasibility analysis. MCML with NTC is shown to yield enhanced power efficiency when operated above 1 GHz with a 100% activity factor as compared to standard CMOS. MCML with NTC is more power efficient than standard CMOS beyond 9 GHz over a wide range of activity factors. MCML with NTC also exhibits significantly lower noise levels as compared to standard CMOS. The results of the analysis demonstrate that pairing NTC and MCML is efficient when operating at high frequencies and activity factors.

  20. A Comparative Study of Improved Artificial Bee Colony Algorithms Applied to Multilevel Image Thresholding

    Directory of Open Access Journals (Sweden)

    Kanjana Charansiriphaisan

    2013-01-01

    Full Text Available Multilevel thresholding is a highly useful tool for the application of image segmentation. Otsu’s method, a common exhaustive search for finding optimal thresholds, involves a high computational cost. There has been a lot of recent research into various meta-heuristic searches in the area of optimization research. This paper analyses and discusses using a family of artificial bee colony algorithms, namely, the standard ABC, ABC/best/1, ABC/best/2, IABC/best/1, IABC/rand/1, and CABC, and some particle swarm optimization-based algorithms for searching multilevel thresholding. The strategy for an onlooker bee to select an employee bee was modified to serve our purposes. The metric measures, which are used to compare the algorithms, are the maximum number of function calls, successful rate, and successful performance. The ranking was performed by Friedman ranks. The experimental results showed that IABC/best/1 outperformed the other techniques when all of them were applied to multilevel image thresholding. Furthermore, the experiments confirmed that IABC/best/1 is a simple, general, and high performance algorithm.

  1. 21 CFR 99.1 - Scope.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Scope. 99.1 Section 99.1 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL DISSEMINATION OF INFORMATION ON UNAPPROVED/NEW USES FOR MARKETED DRUGS, BIOLOGICS, AND DEVICES General Information § 99.1 Scope. (a) This...

  2. Sequential hepatobiliary scintigraphy of the patients with constitutional jaundice, ICG excretory defect disease and hepatocellular carcinoma with 99mTc-PI, 99mTc-HIDA and 99mTc-EHIDA

    International Nuclear Information System (INIS)

    Mitani, Tsuyoshi

    1987-01-01

    Sequential 2 min scintiphotos were obtained with a scintilation camera after intravenous injection of 3 mCi of 99m Tc-HIDA or 99m Tc-PI. Digital matrix images were simultaneously recorded with computer. Sequential samples for the blood clearance of 99m Tc-HIDA or 99m Tc-PI were obtained for 120 min following injection to the patient of constitutional hyperbilirubinemia and ICG excretory defect disease. In Dubin-Johnson syndrome, the hepatic uptake of 99m Tc-HIDA was faster or normal but the excretion was extremely slower than in normal cases. Both hepatic uptake and excretion of 99m Tc-PI were almost normal. In Rotor's disease, hepatic uptake of 99m Tc-HIDA or 99m Tc-PI was very poor, showing almost no hepatic images in all time. In Gilbert's disease and ICG excretory defect disease, hepatic uptake and excretion of 99m Tc-HIDA or 99m Tc-PI were within normal limit. From these results, Dubin-Johnson syndrome, Rotor's disease and Gilbert's disease show the different patterns between hepatic uptake and excretion of 99m Tc-HIDA and 99m Tc-PI hepatobiliary scintigraphy and these patterns contribute to the differential diagnosis of constitutional jaundice. The usefulness of hepatobiliary imaging with 99m Tc-EHIDA in diagnosis of hepatocellular carcinoma was studied in 15 patients with histologically verified HCC. In 15 patients, 3 patients (20 %) showed increased radioactivity with 99m Tc-EHIDA image, where liver scan with 99m Tc-Sn colloid showed filling defect. These results indicate that use of 99m Tc-EHIDA scan and 67 Ga-citrate imaging is useful for positive visualization of HCC. (author)

  3. Characterization of the radioaerosol sup(99m)Tc-DTPA produced by different nebulizers

    International Nuclear Information System (INIS)

    Medeiros, R.B.; Nery, L.E.; Tabacniks, M.H.

    1991-01-01

    Our aim was to characterize the aerosol produced by different nebulizers through the use of sup(99m)Tc-DTPA normally applied in pulmonar ventilation studies in nuclear medicine. We have found the mass distribution's MMD and the geometric standard deviation for this type of radioaerosol. (author)

  4. Preperation and performance of {sup 99}Mo/{sup 99m}Tc chromatographic column generator based on zirconium molybdosilicate

    Energy Technology Data Exchange (ETDEWEB)

    Mostafa, M.; Saber, H.M.; El-Sadek, A.A. [Atomic Energy Authority, Cairo (Egypt). Hot Labs. Center; Nassar, M.Y. [Benha Univ. (Egypt). Chemistry Dept.

    2016-08-01

    Zirconium molybdosilicate (ZrMoSi) gel prepared using {sup 99}Mo radiotracer via peroxo route was used as a base material for {sup 99}Mo/{sup 99m}Tc column generator. The {sup 99m}Tc elution yield and {sup 99}Mo breakthrough in the eluate were studied as a function of the pH-value of gel precipitation, gel drying temperature and Zr: Mo: Si molar ratio. Precipitation pH-value of 2, drying temperature of 100 C and Zr: Mo: Si molar ratio of 0.5: 0.5: 1 were found to be the optimum conditions achieving {sup 99m}Tc elution yield of 82% and {sup 99}Mo breakthrough of 1.0 x 10{sup -3}%. The gel prepared with the optimum conditions was characterized by BET surface area and pore size analyzer, IR spectroscopy, thermal analysis (TGA and DTA), XRD, XRF and FESEM. Technetium-99m eluted from the optimum ZrMoSi {sup 99}Mo/{sup 99m}Tc generator was found to have a high radiochemical purity (98% as {sup 99m}TcO{sub 4}{sup -}) and chemical purity meeting criteria of clinical grade.

  5. Synthesis and irradiation of titanium molybdates used as matrices of the 99 Mo/ 99m Tc generators

    International Nuclear Information System (INIS)

    Diaz V, H.; Monroy G, F.

    2005-01-01

    The 99m Tc is the radioisotope but used in nuclear medicine. Commercially it takes place starting from generators of 99 Mo/ 99m Tc, composed by a chromatography column padded of aluminium oxide of aluminum, where it is deposited the 99 Mo, product of the fission of the 235 U adsorbed and eluted, by means of a saline solution, in form of 99m TcO 4 - . The production of 99 Mo as a result of the fission, imposes radiochemical separations that generate significant quantities of radioactive waste of medium activity, and inflict elaborated radiochemical manipulation. Due to this, its have been carried out intense investigations to substitute the 99 Mo fission product, by chemical compounds that produce 99 Mo via the reaction 98 Mo(n, γ) 99 Mo. Presently work intends the use of gels of titanium molybdates like matrices of these generators. Titanium molybdates were synthesized starting from solutions TiCl 3 and ammonium molybdates and it was studied the effect of the final pH of the gels, the concentration of the Ti +3 and the influence of the laundry of these on the acting of generators. The best efficiencies and chemical purity, radiochemical and radionuclides of the gels like matrices of generators 99 Mo/ 99m Tc were gotten with the washed gel, elaborated with the solution of TiCI 3 0.35M, and to a final pH of 5.9 (Author)

  6. Actions needed to ensure a reliable supply of 99Mo and 99mTc?

    International Nuclear Information System (INIS)

    Cameron, R.; Peykov, P.

    2014-01-01

    The NEA established the High-level Group on the Security of Supply of Medical Radioisotopes (HLG-MR) to examine the causes of 99 Mo/ 99 mTc supply shortages in 2009. It undertook an economic analysis and determined that lack of economic sustainability in producing reactors was the major cause of the shortages. From that it developed a policy approach, including principles and supporting recommendations to address those causes. Since then it has looked at the way the supply chain has implemented these policy principles through initiating a self-assessment process, which revealed uneven application and lack of adherence to the key principle of full cost recovery. As part of the analysis, the NEA has also reviewed the global 99 Mo/ 99 mTc supply situation periodically, using the most up-to-date data from supply chain participants, to highlight periods of reduced supply and underscore the case for implementing the HLG-MR policy approach in a timely and globally-consistent manner. This current paper presents the preliminary results from an updated 99 Mo supply and demand forecast, focusing on the potentially critical 2015-2020 period, when two major 99 Mo producers (the NRU reactor in Canada and the OSIRIS reactor in France) are scheduled to cease 99 Mo irradiations. It concludes with a review of the effectiveness of the actions taken to date and indicates where further action is needed. (author)

  7. Silica-gel modified with zirconium oxide as a novel 99Mo adsorbent 99mTc generators

    International Nuclear Information System (INIS)

    Salehi, H.; Mollarazi, E.; Abbasi, H.

    2010-01-01

    A new 99 Mo adsorbent has been prepared with modified silica gel with zirconium oxide (SiO 2 /ZrO 2 :Na 2 MoO 4 ) and used in technetium-99m generator. The adsorption behaviors of 99 Mo in the form of molybdate and 99m Tc in the form of pertechnetate on the new adsorbent was investigated showed that the adsorption capacity of molybdate on this generator was considerably higher than the usual generator with alumina column. Coating zirconium oxide on the surface of silica gel resulted in higher 99 Mo adsorption of this compound. 99m Tc is eluted with 0.9% NaCl, and the radionuclidic, radiochemical and chemical purities of the eluate were checked. This generator has a great potential as compared to the traditional alumina generators.

  8. 29 CFR 99.310 - Financial statements.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Financial statements. 99.310 Section 99.310 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Auditees § 99... have separate audits in accordance with § 99.500(a) and prepare separate financial statements. (b...

  9. 29 CFR 99.300 - Auditee responsibilities.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Auditee responsibilities. 99.300 Section 99.300 Labor Office... § 99.300 Auditee responsibilities. The auditee shall: (a) Identify, in its accounts, all Federal awards... the schedule of expenditures of Federal awards in accordance with § 99.310. (e) Ensure that the audits...

  10. 29 CFR 99.200 - Audit requirements.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Audit requirements. 99.200 Section 99.200 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Audits § 99.... Guidance on determining Federal awards expended is provided in § 99.205. (b) Single audit. Non-Federal...

  11. Clearance of 99mTc-DTPA and experimentally increased alveolar surfactant content

    International Nuclear Information System (INIS)

    Bos, J.A.H.; Wollmer, P.; Bakker, W.; Hannappel, E.; Lachmann, B.

    1992-01-01

    The authors measured clearance of 99m Tc-labeled diethylenetriamine pentaacetic acid ( 99m Tc-DTPA) in rabbits with experimentally increased alveolar surfactant content. In one group of animals, surfactant production was increased by treatment with ambroxol, and another group of animals was treated with tracheal instillation of natural surfactant. A group of untreated control animals and animals treated with instillation of saline were also studied. Clearance was measured during standard conditions of mechanical ventilation and during ventilation with large tidal volumes. In ambroxol- and surfactant-treated groups, clearance rate was reduced compared with untreated control animals. In contrast, clearance rate increased after saline instillation. The differences were observed at both modes of ventilation. The findings indicate that the pulmonary surfactant system is a rate-limiting factor for the clearance of 99m Tc-DTPA and that the volume dependence of clearance is not explained by stretching of the alveolar wall only. 28 refs., 2 figs., 1 tab

  12. Progress on the Development of (n,γ)99Mo/99mTc generator, an Alternative of Conventional Generator

    International Nuclear Information System (INIS)

    Lee, Jun Sig; Choi, Seung Rag; Nam, Seong Su; Park, Ul Jae; Son, Kwang Jae; Choi, Kang Hyuk; Choi, Sun Ju

    2010-01-01

    Even though different types of generators have been developed to extract 99m Tc, most of the generators uses 99 Mo from the fission products as the mother radionuclide of 99m Tc. Recently, the crisis of 99 Mo production becomes one of the international issues as 99m Tc is a dominant diagnostic radionuclide. The shortage of 99m Tc has been predicted in the society for more than 10 years. However, actions to prevent such crisis were slow as the initial investment to construct a new research reactor for the production of 99 Mo is high. Currently, it is expected the shortage of 99m Tc will last at least for more than 5 years. As an alternative to minimize such crisis, a new approach is proposed and studied. In this approach, the mother source of 99m Tc comes not from fission products but from the neutron irradiation of molybdenum oxide. Hence, most of the research reactors, which do not have capability to produce fission molybdenum, (n,f) 99 Mo can produce 99 Mo. The key issue in this approach is the uptake capacity of the generator column for (n, γ) 99 Mo, which has extremely low specific activity compared to (n,f) 99 Mo. Currently, the results from the research activities at Korea Atomic Energy Research Institute have shown such approach has enough potential as an alternative of the conventional generator. Hence, the progress of the research is reported in this paper

  13. 45 CFR 99.13 - Place.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Place. 99.13 Section 99.13 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION PROCEDURE FOR HEARINGS FOR THE CHILD CARE AND DEVELOPMENT FUND Preliminary Matters-Notice and Parties § 99.13 Place. The hearing shall be held in the city...

  14. 29 CFR 99.225 - Sanctions.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Sanctions. 99.225 Section 99.225 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Audits § 99.225 Sanctions. No audit costs may be charged to Federal awards when audits required by this part have not been...

  15. Current status of research and development of 99Mo/99mTc generator in Korea

    International Nuclear Information System (INIS)

    Park, U.J.; Lee, J.S.; Son, K.J.; Nam, S.S.; Kwak, S.I.; Han, H.S.

    2006-01-01

    To supply 99m Tc in stable and economical manner in Korea, a chromatographic generator has been under development at KAERI since late 1980's. The chromatographic type of technetium generator is preferred in hospital because it is more convenient and less time-restricted for applications. Hence, the demand of 99m Tc in medical applications is keep increasing. In Korea, there are more than 200 gamma cameras including SPECT in hospitals. For these applications, approximately 100 units/week of 99m Tc generators of which annual cost reached 3 million US dollars were required in 2002. Hence, the development of 99m Tc generators and technology of fission 99 Mo processing were started while installing the generator loading facility (GLF) at KAERI. This facility is currently on a trial run for the commercial production of 99m Tc generators and expected to produce more than 200 generators per week in 2004. For the fission 99 Mo production, an annulus U foil target was considered as the LEU target. The designed LEU target is being used for target manufacturing test and accident analysis. The develop gel type 99m Tc generators by using a poly zirconium complex (PZC) and alumina column, KAERI has cooperated with a Japanese company since late 1990's. In 2003, experimental studies for molybdate adsorption capacity and elution characteristics of the PZC samples from three different batches produced by Kaken Co. were carried out. (author)

  16. Three-dimensional display of 99mTc-MIBI myocardial scintigraphy

    International Nuclear Information System (INIS)

    Kashimada, Akio; Machida, Kikuo; Honda, Norinari

    1992-01-01

    One of 99m Tc-hexakis, 99m Tc-methoxyisobutyl isonitrile (MIBI), has been demonstrated to have a myocardial uptake proportional to regional coronary blood flow. In this study, 99m Tc-MIBI myocardial scintigraphy was performed for 16 patients with ischemic heart disease. After injection of 740 MBq of 99m Tc-MIBI, 64 projection images were collected during a 360-degree rotation. Three-dimensional (3D) display of the left ventricle was reconstructed with depth-shading method from 99m Tc-MIBI SPECT images, which were reconstructed by filtered back projection method. In 9 of the patients, left ventricular cineangiography were performed as diagnostic gold standard. Four physicians blinded to patients' clinical information interpreted 3D images and SPECT images on separate occasions. Diagnosis of hypoperfusion by 3D displays agreed with those of SPECT in 92.9% (104/112 segments), and disagreed in 7.1% (8 segments). Sensitivity and specificity of 3D images were 87.0% and 93.9%, which were not statistically different (p<0.05) from that of SPECT images (91.3%, 97.0%). Receiver operating characteristic (ROC) analysis revealed nearly identical curves for the two. Although 3D display had nearly identical diagnostic ability with SPECT, observers reported that 3D images were easier to diagnose than SPECT images. An advantage of the 3D display is that the display gives a more realistic impression of the left ventricle to an observer than tomography or planar imaging. Another advantage is that 3D display can reduce the amount of data storage compared with that of SPECT. In conclusion, 3D images may be useful for diagnosis of hypoperfusion of left ventricle. (author)

  17. Dynamic radionuclide imaging with 99mTc-sucralfate in the detection of oesophageal ulceration.

    Science.gov (United States)

    Mearns, A J; Hart, G C; Cox, J A

    1989-01-01

    Standard oesophageal scintigraphic techniques using 99mTc-colloids rarely identify oesophageal mucosal damage. Sucralfate can be labelled with 99mTc for the detection of oesophageal mucosal ulceration. This method uses two separate supine swallows of 10 MBq 99mTc-colloid in 10 ml, followed by a single supine swallow of 30 MBq 99mTc-sucralfate. The data are processed to give time-activity curves, mean transit times and condensed dynamic images. When oesophageal ulceration is detected, the time-activity curves using sucralfate show residual activity in the oesophagus after the transit time indicated by the colloid swallow. The condensed dynamic image shows a persistence of activity at the level of the ulceration. Erect sucralfate images taken immediately after the dynamic sequence show no oesophageal localisation. The results from a study of 62 patients have shown excellent correlation between the dynamic 99mTc-sucralfate images and endoscopy findings. Sequential sucralfate studies for healing also correlate well. The use of labelled sucralfate to detect oesophageal ulceration could modify the indications for endoscopy in gastrooesophageal reflux disease. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 PMID:2806994

  18. 29 CFR 99.405 - Management decision.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Management decision. 99.405 Section 99.405 Labor Office of... Agencies and Pass-through Entities § 99.405 Management decision. (a) General. The management decision shall... process available to the auditee. (b) Federal agency. As provided in § 99.400(a)(7), the cognizant agency...

  19. 29 CFR 99.510 - Audit findings.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Audit findings. 99.510 Section 99.510 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Auditors § 99.510 Audit... schedule of prior audit findings prepared by the auditee in accordance with § 99.315(b) materially...

  20. Fuzzy 2-partition entropy threshold selection based on Big Bang–Big Crunch Optimization algorithm

    Directory of Open Access Journals (Sweden)

    Baljit Singh Khehra

    2015-03-01

    Full Text Available The fuzzy 2-partition entropy approach has been widely used to select threshold value for image segmenting. This approach used two parameterized fuzzy membership functions to form a fuzzy 2-partition of the image. The optimal threshold is selected by searching an optimal combination of parameters of the membership functions such that the entropy of fuzzy 2-partition is maximized. In this paper, a new fuzzy 2-partition entropy thresholding approach based on the technology of the Big Bang–Big Crunch Optimization (BBBCO is proposed. The new proposed thresholding approach is called the BBBCO-based fuzzy 2-partition entropy thresholding algorithm. BBBCO is used to search an optimal combination of parameters of the membership functions for maximizing the entropy of fuzzy 2-partition. BBBCO is inspired by the theory of the evolution of the universe; namely the Big Bang and Big Crunch Theory. The proposed algorithm is tested on a number of standard test images. For comparison, three different algorithms included Genetic Algorithm (GA-based, Biogeography-based Optimization (BBO-based and recursive approaches are also implemented. From experimental results, it is observed that the performance of the proposed algorithm is more effective than GA-based, BBO-based and recursion-based approaches.

  1. 29 CFR 99.505 - Audit reporting.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Audit reporting. 99.505 Section 99.505 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Auditors § 99.505 Audit... is required to report under § 99.510(a); (vii) An identification of major programs; (viii) The dollar...

  2. 29 CFR 99.320 - Report submission.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Report submission. 99.320 Section 99.320 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Auditees § 99.320... package pursuant to § 99.320(d)(2). (vii) A yes or no statement as to whether the auditee qualified as a...

  3. 29 CFR 99.230 - Audit costs.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Audit costs. 99.230 Section 99.230 Labor Office of the Secretary of Labor AUDITS OF STATES, LOCAL GOVERNMENTS, AND NON-PROFIT ORGANIZATIONS Audits § 99.230 Audit... years ending after December 31, 2003) and is thereby exempted under § 99.200(d) from having an audit...

  4. Comparative evaluation of different nanostructured metal oxides for preparation of clinically useful 99Mo/99mTc generators

    International Nuclear Information System (INIS)

    Ram, Ramu; Chakravarty, Rubel; Dash, Ashutosh

    2015-01-01

    The potential of nanostructured metal oxides such as nanotitania, nanozirconia, nanoalumina and mesoporous alumina, as new generation sorbent materials for preparation of 99 Mo/ 99m Tc generator has recently been demonstrated. A comparative assessment of such materials is essential for determination of their suitability for preparation of clinically useful generators using (n,γ) 99 Mo. Characteristics which were compared included the sorption capacity, shelf-life of the generator, radioactive concentration and purity of 99m Tc for radiopharmaceutical applications. Mesoporous alumina was identified as the most suitable sorbent for ensuring sustainable production of clinical grade 99 Mo/ 99m Tc generators using low specific activity 99 Mo. (author)

  5. Accumulation of Tc-99m-MIBI and Tc-99m-tetrofosmin in tumor cells. Uptake and washout studies

    International Nuclear Information System (INIS)

    Rodrigues, M.; Aghajanian, A.A.; Sinzinger, H.; Kalinowska, W.; Zielinski, C.

    2002-01-01

    Aim: To investigate in-vitro the uptake and washout of Tc-99m-MIBI and Tc-99m-tetrofosmin in human breast adenocarcinoma and soft tissue sarcoma cell lines. Methods: The uptake of Tc-99m-MIBI and Tc-99m-tetrofosmin (at 37 0 C, 10, 30 and 60 minutes after incubation with 7.4x10E5 Bq each tracer) was investigated in breast adenocarcinoma MCF-7 and SK-BR-3 cells, synovial sarcoma SW 982 cells and chondrosarcoma SW 1353 cells (concentration of 1x10E6 cells/ml incubation medium). Tracer uptake in cells incubated with ouabain (Na/K-ATPase pump inhibitor; 100 μM and 1mM; 15 and 30 minutes), nigericin (increases mitochondrial potential and disrupts cell membrane potential; 5 and 50 μg/ml; 15 minutes) and carbonyl cyanide m-chlorophenylhydrazone (CCCP) (depolarizes mitochondrial membrane; 10 and 100 μM; 30 minutes) was compared to that in cells without incubation with chemical agents (control cells). The washout (at 37 0 C, 10-60 minutes, 30 and 60 minutes after tracer incubation) of Tc-99m-MIBI and Tc-99m-tetrofosmin was studied in MCF-7 cells, SK-BR-3 cells , SW 1353 cells and fibrosarcoma SW 684 cells. Results: Cellular tracer uptake decreased with ouabain (decrease of Tc-99m-tetrofosmin > Tc-99m-MIBI in SK-BR-3 cells and SW 982 cells) and increased with nigericin (increase of Tc-99m-MIBI > Tc-99m-tetrofosmin in all cells) as compared to the uptake in control cells. With CCCP, decrease of Tc-99m-MIBI uptake in cells preincubated with nigericin was higher than that in cells under basal conditions, whereas a similar decrease of Tc-99m-tetrofosmin uptake in these two group of cells was found. Washout of Tc-99m-MIBI from all cells was lower than that of Tc-99m-tetrofosmin. No significant difference in cell-associated activity of both tracers was found between washout after 30 minutes and that after 60 minutes of incubation, in all cells. Washout of Tc-99m-MIBI from SK-BR-3 cells Tc-99m-tetrofosmin) and Na/K-ATPase pump (Tc-99m-tetrofosmin > Tc-99m-MIBI). Tc-99m-MIBI and

  6. Can adaptive threshold-based metabolic tumor volume (MTV) and lean body mass corrected standard uptake value (SUL) predict prognosis in head and neck cancer patients treated with definitive radiotherapy/chemoradiotherapy?

    Science.gov (United States)

    Akagunduz, Ozlem Ozkaya; Savas, Recep; Yalman, Deniz; Kocacelebi, Kenan; Esassolak, Mustafa

    2015-11-01

    To evaluate the predictive value of adaptive threshold-based metabolic tumor volume (MTV), maximum standardized uptake value (SUVmax) and maximum lean body mass corrected SUV (SULmax) measured on pretreatment positron emission tomography and computed tomography (PET/CT) imaging in head and neck cancer patients treated with definitive radiotherapy/chemoradiotherapy. Pretreatment PET/CT of the 62 patients with locally advanced head and neck cancer who were treated consecutively between May 2010 and February 2013 were reviewed retrospectively. The maximum FDG uptake of the primary tumor was defined according to SUVmax and SULmax. Multiple threshold levels between 60% and 10% of the SUVmax and SULmax were tested with intervals of 5% to 10% in order to define the most suitable threshold value for the metabolic activity of each patient's tumor (adaptive threshold). MTV was calculated according to this value. We evaluated the relationship of mean values of MTV, SUVmax and SULmax with treatment response, local recurrence, distant metastasis and disease-related death. Receiver-operating characteristic (ROC) curve analysis was done to obtain optimal predictive cut-off values for MTV and SULmax which were found to have a predictive value. Local recurrence-free (LRFS), disease-free (DFS) and overall survival (OS) were examined according to these cut-offs. Forty six patients had complete response, 15 had partial response, and 1 had stable disease 6 weeks after the completion of treatment. Median follow-up of the entire cohort was 18 months. Of 46 complete responders 10 had local recurrence, and of 16 partial or no responders 10 had local progression. Eighteen patients died. Adaptive threshold-based MTV had significant predictive value for treatment response (p=0.011), local recurrence/progression (p=0.050), and disease-related death (p=0.024). SULmax had a predictive value for local recurrence/progression (p=0.030). ROC curves analysis revealed a cut-off value of 14.00 mL for

  7. Technetium-99 m generator safety simulation

    International Nuclear Information System (INIS)

    Kang, Sang Koo; Kim, Chong Yeal

    2008-01-01

    Technetium ( 99m Tc) is one of the most widely used radioactive isotopes for diagnosis in the world. In general, 99m Tc is produced inside the so called technetium generator where 99Mo decays to 99m Tc. And the generator is usually made out of lead to shield relatively high energy radiation from 99m Tc and 99 Mo. In this paper, a GEANT4 simulation is carried out to test the safety of the 99m Tc generators, taking domestic and Japanese products with radioactivity of 18.50 GBq (500 mCi) for example. According to the domestic regulation on radiation safety, the dose at 10 cm and 100 cm away from the surface of radiation shielder should not exceed 2 mSv∙h -1 and 0.02 mSv∙h -1 , respectively. The simulated dose turned out about only 10% of the limit, satisfying the domestic regulation

  8. BEAUTY'99 Conference Summary

    International Nuclear Information System (INIS)

    Eerola, Paula

    2000-01-01

    Investigations of B hadrons are expected to break new ground in measuring CP-violation effects. This series of BEAUTY conferences, originating from the 1993 conference in Liblice, has contributed significantly in developing ideas of CP-violation measurements using B hadrons and formulating and comparing critically the B-physics experiments. In the '99 conference in Bled we saw the ripening of the field and the first fruit emerging - Tevatron have produced beautiful B-physics results and more are expected to come with the next run, while the B-physics experiments at DESY, SLAC and KEK are starting their operation. The longer-term projects at LHC and Tevatron have taken their shape and detailed prototyping work is going on. Meanwhile, on the phenomenological side, there has been impressive theoretical progress in understanding deeper the 'standard' measurements and proposing new signatures. In this summary, I will highlight the status of the field as presented in the conference, concentrating on signatures, experiments and R and D programmes

  9. Pulmonary and symptom threshold effects of ozone in airline passenger and cockpit crew surrogates

    Energy Technology Data Exchange (ETDEWEB)

    Lategola, M.T.; Melton, C.E.; Higgins, E.A.

    1980-09-01

    Previous studies showed that the ozone concentration for pulmonary and symptom threshold effects in flight attendant surrogates lies between 0.20 and 0.30 ppMv for a 3-h exposure with intermittent treadmill exercise at 1829 m (MSL) stimulated cabin altitude. In the present study of sedentary occupants of the in-flight airline cabin, the same protocol was used except for omitting all treadmill exercise. Symptoms were assessed with a standardized questionnaire. Pulmonary function was assessed using standardized quantitative spirometry. Male smoker and nonsmoker airline passenger and cockpit crew surrogates 40 to 59 years of age were used. Small but statistically significant displacements occurred in symptoms and in some spirometry parameters. In general, the younger subjects appeared more sensitive to ozone than the older subjects. No significant differences appeared between smokers' and nonsmokers' responses to ozone exposure. It is concluded that the ozone threshold of these sedentary surrogates under these experimental conditions is right at 0.30 ppMv.

  10. Comparison of uptake of 99mTc-MIBI, 99mTc-tetrofosmin and 99mT-Q12 into human breast cancer cell lines

    International Nuclear Information System (INIS)

    Yong, M. de; Bernard, B.F.; Breeman, W.A.P.; Ensing, G.; Benjamins, H.; Bakker, W.H.; Visser, T.J.; Krenning, E.P.

    1996-01-01

    Technetium-99m hexakis-2-methoxyisobutyl-isonitrile (MIBI), 99m Tc-tetrofosmin and 99m Tc-Q12 were all introduced for myocardial imaging but found additional applications as they are taken up by different tumours, enabling imaging of these lesions in patients. The aim of this study was to compare the uptake characteristics of these compounds in vitro in the human adenocarcinoma breast cell lines MCF-7 and ZR-75. It was shown that 99m Tc-MIBI had the highest cellular uptake (15.9%±0.5% dose/mg protein after 60 min in MCF-7, and 14.2%±0.4% dose/mg protein in ZR-75), followed by 99m Tc-tetrofosmin (6.8%±0.6% dose/mg protein in MCF-7, and 8.2%±0.2% dose/mg protein in ZR-75) and 99m TC-Q12 (3.2%±0.1% dose/mg protein in MCF-7, and 3.5%±0.3% dose/mg protein in ZR-75 cells). For all three compounds tenfold differences in specific activity did not influence total cell-associated radioactivity. Uptake of 99m Tc-MIBI and 99m Tc-tetrofosmin was obviously lower at 4 C than at 37 C, whereas 99m Tc-Q12 uptake showed only slight temperature dependence. When uptake was compared in cells grown to different cell densities (1 mg/ml cellular protein versus 0.3 mg/ml), no differences in uptake were detected when uptake was corrected for the amount of cellular protein present in the dishes. Furthermore, for all compounds it was shown that cellular radioactivity decreased rapidly after washing. Apart from the differences in cellular uptake of the three compounds after 60 min, no differences in residual cellular radioactivity after washing were found between the different compounds when expressed as a percentage of their 60-min uptake, suggesting that the efflux process of the radiolabelled compounds was similar. The differences in cell-associated activity after 60 min were thus presumably caused by differences in uptake. (orig./MG)

  11. Hyper-arousal decreases human visual thresholds.

    Directory of Open Access Journals (Sweden)

    Adam J Woods

    Full Text Available Arousal has long been known to influence behavior and serves as an underlying component of cognition and consciousness. However, the consequences of hyper-arousal for visual perception remain unclear. The present study evaluates the impact of hyper-arousal on two aspects of visual sensitivity: visual stereoacuity and contrast thresholds. Sixty-eight participants participated in two experiments. Thirty-four participants were randomly divided into two groups in each experiment: Arousal Stimulation or Sham Control. The Arousal Stimulation group underwent a 50-second cold pressor stimulation (immersing the foot in 0-2° C water, a technique known to increase arousal. In contrast, the Sham Control group immersed their foot in room temperature water. Stereoacuity thresholds (Experiment 1 and contrast thresholds (Experiment 2 were measured before and after stimulation. The Arousal Stimulation groups demonstrated significantly lower stereoacuity and contrast thresholds following cold pressor stimulation, whereas the Sham Control groups showed no difference in thresholds. These results provide the first evidence that hyper-arousal from sensory stimulation can lower visual thresholds. Hyper-arousal's ability to decrease visual thresholds has important implications for survival, sports, and everyday life.

  12. Thermal neutron cross section measurements for technetium-99

    International Nuclear Information System (INIS)

    Yates, M.A.; Schroeder, N.C.; Fowler, M.M.

    1993-01-01

    Technetium, because of its long half-like (213,000 years) and ability to migrate in the environment, is a primary contributor to the long-term radioactivity related risk associated with geologic nuclear waste disposal. One proposal for converting technetium to an environmentally benign element investigating transmutation with an accelerator-based system, (i.e., Accelerator Transmutation of Waste, ATW). Planning for efficient processing of technetium through the transmuter will require knowledge of the thermal neutron cross section for the 99 Tc (n,γ) 100 Tc reaction. The authors have recently remeasured this cross section. Weighed aliquots (19-205 μg) of a NIST traceable 99 Tc standard were irradiated for 30-150 sec using the pneumatic open-quotes rabbitclose quotes system of LANL's Omega West Reactor. The two gamma rays from the 15.7-sec half-life product were measured immediately after irradiation on a high-resolution Ge detector. Thermal fluxes were measured using gold foils and Cd wrapped gold foils. The observation cross section is 19 ± 1 b. This agrees well with the 1977 value but has half the uncertainty

  13. 99mTc by 99Mo produced at the ENEA-FNG facility of 14MeV neutrons.

    Science.gov (United States)

    Capogni, M; Pietropaolo, A; Quintieri, L; Fazio, A; De Felice, P; Pillon, M; Pizzuto, A

    2018-04-01

    A severe supply crisis of 99 Mo, precursor of 99m Tc a diagnostic radionuclide largely used in Nuclear Medicine, occurred in 2008-2009 due to repeated shut-down of the two main (aged) fission reactors. An alternative route for producing 99 Mo by 100 Mo(n,2n) 99 Mo reaction was investigated at ENEA. The experiment, designed according to Monte Carlo simulations performed with the Fluka code, produced 99 Mo by irradiating a natural Molybdenum powdered target with 14MeV neutrons produced at the Frascati Neutron Generator. The 99 Mo specific activity was measured at metrological level by γ-ray spectrometry. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Production optimization of {sup 99}Mo/{sup 99m}Tc zirconium molybate gel generators at semi-automatic device: DISIGEG

    Energy Technology Data Exchange (ETDEWEB)

    Monroy-Guzman, F., E-mail: fabiola.monroy@inin.gob.mx [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca S/N, La Marquesa, Ocoyoacac, 52750, Estado de Mexico (Mexico); Rivero Gutierrez, T., E-mail: tonatiuh.rivero@inin.gob.mx [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca S/N, La Marquesa, Ocoyoacac, 52750, Estado de Mexico (Mexico); Lopez Malpica, I.Z.; Hernandez Cortes, S.; Rojas Nava, P.; Vazquez Maldonado, J.C. [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca S/N, La Marquesa, Ocoyoacac, 52750, Estado de Mexico (Mexico); Vazquez, A. [Instituto Mexicano del Petroleo, Eje Central Norte Lazaro Cardenas 152, Col. San Bartolo Atepehuacan, 07730, Mexico D.F. (Mexico)

    2012-01-15

    DISIGEG is a synthesis installation of zirconium {sup 99}Mo-molybdate gels for {sup 99}Mo/{sup 99m}Tc generator production, which has been designed, built and installed at the ININ. The device consists of a synthesis reactor and five systems controlled via keyboard: (1) raw material access, (2) chemical air stirring, (3) gel dried by air and infrared heating, (4) moisture removal and (5) gel extraction. DISIGEG operation is described and dried condition effects of zirconium {sup 99}Mo- molybdate gels on {sup 99}Mo/{sup 99m}Tc generator performance were evaluated as well as some physical-chemical properties of these gels. The results reveal that temperature, time and air flow applied during the drying process directly affects zirconium {sup 99}Mo-molybdate gel generator performance. All gels prepared have a similar chemical structure probably constituted by three-dimensional network, based on zirconium pentagonal bipyramids and molybdenum octahedral. Basic structural variations cause a change in gel porosity and permeability, favouring or inhibiting {sup 99m}TcO{sub 4}{sup -} diffusion into the matrix. The {sup 99m}TcO{sub 4}{sup -} eluates produced by {sup 99}Mo/{sup 99m}Tc zirconium {sup 99}Mo-molybdate gel generators prepared in DISIGEG, air dried at 80 Degree-Sign C for 5 h and using an air flow of 90 mm, satisfied all the Pharmacopoeias regulations: {sup 99m}Tc yield between 70-75%, {sup 99}Mo breakthrough less than 3 Multiplication-Sign 10{sup -3}%, radiochemical purities about 97% sterile and pyrogen-free eluates with a pH of 6. - Highlights: Black-Right-Pointing-Pointer {sup 99}Mo/{sup 99m}Tc generators based on {sup 99}Mo-molybdate gels were synthesized at a semi-automatic device. Black-Right-Pointing-Pointer Generator performances depend on synthesis conditions of the zirconium {sup 99}Mo-molybdate gel. Black-Right-Pointing-Pointer {sup 99m}TcO{sub 4}{sup -} diffusion and yield into generator depends on gel porosity and permeability. Black

  15. Threshold and resilience management of coupled urbanization and water environmental system in the rapidly changing coastal region

    International Nuclear Information System (INIS)

    Li, Yangfan; Li, Yi; Wu, Wei

    2016-01-01

    The concept of thresholds shows important implications for environmental and resource management. Here we derived potential landscape thresholds which indicated abrupt changes in water quality or the dividing points between exceeding and failing to meet national surface water quality standards for a rapidly urbanizing city on the Eastern Coast in China. The analysis of landscape thresholds was based on regression models linking each of the seven water quality variables to each of the six landscape metrics for this coupled land-water system. We found substantial and accelerating urban sprawl at the suburban areas between 2000 and 2008, and detected significant nonlinear relations between water quality and landscape pattern. This research demonstrated that a simple modeling technique could provide insights on environmental thresholds to support more-informed decision making in land use, water environmental and resilience management. - Graphical abstract: Fig. Threshold models and resilience management for water quality. Display Omitted - Highlights: • Coupling urbanization and water environmental system. • Developing threshold models of the coupled land-water systems. • Nonlinear relations between water quality variables and landscape metrics. • Enhancing resilience management of coastal rapid urbanization. - We develop environmental threshold models and provide their implications on resilience management for a coupled land-water system with rapid urbanization.

  16. A numerical study of threshold states

    International Nuclear Information System (INIS)

    Ata, M.S.; Grama, C.; Grama, N.; Hategan, C.

    1979-01-01

    There are some experimental evidences of charged particle threshold states. On the statistical background of levels, some simple structures were observed in excitation spectrum. They occur near the coulombian threshold and have a large reduced width for the decay in the threshold channel. These states were identified as charged cluster threshold states. Such threshold states were observed in sup(15,16,17,18)O, sup(18,19)F, sup(19,20)Ne, sup(24)Mg, sup(32)S. The types of clusters involved were d, t, 3 He, α and even 12 C. They were observed in heavy-ions transfer reactions in the residual nucleus as strong excited levels. The charged particle threshold states occur as simple structures at high excitation energy. They could be interesting both from nuclear structure as well as nuclear reaction mechanism point of view. They could be excited as simple structures both in compound and residual nucleus. (author)

  17. Study of the elution {sup 99}Mo-{sup 99m}Tc generators produced at IPEN-CNEN/SP

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, Paula Regina Corain [Pontificia Univ. Catolica de Sao Paulo, SP (Brazil); Instituto de Pesquisas Energeticas e Nucleares IPEN/CNEN-SP, Sao Paulo, SP (Brazil)]. E-mail: corain.lopes@uol.com.br; Osso Junior, Joao Alberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: jaosso@ipen.br

    2007-07-01

    Over the last years {sup 99m}Tc has become a very important asset in modern nuclear medicine, due to the emission of gamma ray of optimal energy (140 keV) and a suitable half-life (6.04 h). A further attribute of {sup 99m}Tc is its formation from the decay of {sup 99}Mo and the availability from {sup 99}Mo-{sup 99m}Tc generator systems. The most common and practical generator types consist of a chromatographic column packed with aluminium oxide, onto which the highly purified fission product {sup 99}Mo (imported from Canada) is adsorbed in the form of molybdate. {sup 99m}Tc is further eluted with saline solution. The objective of this work is to study the performance and the elution profile of {sup 99m}Tc from high activity generators in order to decrease molybdenum and aluminium concentration. The experiments involved the use of paper filters and Sep Pak columns and also the changing in the time interval between elutions. {sup 99}Mo breakthrough was measured using a dose calibrator and aluminium by UV-Vis spectrophotometry. The best results were achieved using a Sep Pak column containing neutral aluminium oxide. (author)

  18. Improvement of Safety Features in Standard Operation Procedure of Tc-99m Generator

    International Nuclear Information System (INIS)

    Manisah Saedon; Mohd Khairul Hakimi; Shyen, A.K.S.

    2011-01-01

    This paper describes the improvements proposed to the original production procedures for Tc-99m generators. Improvements are intended to add safety and health features for workers into the existing procedures. The difference between the new safe work procedures from the original work procedures; is the concern about the safety and health of employees other than the product safety. One of the suggested safety characteristics is by using the visual aid so that the workers can easily see and read the procedures when they perform their duties, whereas the previous procedures are kept in the manual and difficult to access. The purpose of this paper is to share information about the importance of safety and health features for the workers in the procedures established in addition to provide awareness to all parties involved. (author)

  19. Clinical application of 99Tcm-tetrofosmin in diagnosis patients with coronary heart disease

    International Nuclear Information System (INIS)

    Li Na; Chen Song; Wang Xiaobei; Wang Ying; Yin Yafu; Li Xuena; Li Yaming; Wang Lijuan; He Zuoxiang

    2012-01-01

    Objective: To evaluate the diagnostic value of 99 Tc m -tetrofosmin(TF) stress-rest MPI in detecting CHD. Methods: Eighty patients with suspected CHD who had stress-rest MPI from October 2009 to April 2011 were retrospectively analyzed.Forty underwent 99 Tc m -TF (group A) and 40 received 99 Tc m -MIBI (group B) stress-rest MPI. Heart/lung (H/L) ratios of these two groups were compared.CAG was performed on group A patients 3 months before and after MPI. Stenosis of more than 50% in CAG was used as a standard to evaluate the diagnostic efficiency of 99 Tc m -TF MPI. Paired t test and χ 2 test were used to compare the data. Results: H/L ratios of rest and stress from 99 Tc m -TF images were 6.73 ± 1.21 and 6.94 ± 1.69, while those from 99 Tc m -MIBI images were 6.58 ± 1.94 and 6.64 ± 1.81, respectively. There was no difference between 99 Tc m -TF and 99 Tc m -MIBI imaging in both rest and stress (t=0.41, 0.78, both P>0.05). There was no difference between H/L ratios from stress and rest 99 Tc m -TF imaging (t=0.69, P >0.05). Twenty-four patients who underwent 99 Tc m -TF imaging had abnormal perfusion (60.0%, 24/40), including 20 LAD, 11 LCX and 14 RCA. Twenty-three among these 40 patients had abnormal CAG results (57.5%, 23/40), including 19 LAD, 12 LCX, and 11 RCA. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of 99 Tc m -TF stress-rest MPI were 87.0% (20/23), 76.5% (13/17), 82.5% (33/40), 83.3% (20/24) and 81.2% (13/16), respectively. The sensitivities of 99 Tc m -TF stress-rest MPI for detection of LAD, LCX and RCA were 89.5% (17/19), 83.3% (10/12) and 90.9% (10/11), respectively,and positive predictive values were 85.0% (17/20), 90.9% (10/11) and 71.4% (10/14), respectively. There was no significant difference for sensitivity and positive predictive value of 99 Tc m -TF MPI among different vessels (χ 2 =0.377 and 1.789, both P>0.05). Conclusions: 99 Tc m -TF MPI has comparative imaging quality to 99 Tc m

  20. Evaluation of radionuclide calibrator performance with Tc-99m and I-123 in nuclear medicine centers

    International Nuclear Information System (INIS)

    Ahn, Ji Young; Kim, Gwe Ya; Yang, Hyun Kyu; Lim, Chun Il; Lee, Hyun Koo; Kim, Byung Tae; Jeong, Hee Kyo

    2004-01-01

    To minimize unnecessary radiation dose to patients, it is important to ensure that the radiopharmaceutical administered is accurately measured. Tc-99m is one of the popular radionuclide used in nuclear medicine and I-123 is also used widely in nuclear medicine. To investigate the level of measurement performance and to provide the participants with a traceable standard to check and review their calibration factors for these particular radionuclides, Korean Food and Drug Administration (KFDA) as a national secondary standard dosimetry laboratory conducted comparison program for Tc-99m and I-123 in nuclear medicine centers. 72 nuclear medicine centers (78 calibrators) participated in the comparison program for Tc-99m in 2003 and 37 centers (41 calibrators) for I-123 in 2004. For a comparison, Tc-99m and I-123 were accurately sub-divided into a series of 4 ml aliquots in 10 ml P6 vial and delivered to participants. Participants were invited to assay their P6 vial in each of their radionuclide calibrators and to report their results directly to KFDA. For the evaluation of raionuclide, KFDA used NPL-CRC radionuclide calibrator that is traceable to NPL (National Physical Laboratory) primany standard. The difference between the value reported by the hospital (A h ospital) and of the KFDA (A k fda) is expressed as a percent deviation (DEV (%) = 100 (A h ospital - A k fda)/A k fda). If there were calibrators over 10 % deviations, those were checked again with the same procedure. In Tc-99m, 65% of the calibrators showed deviations within 5 % and 18 % were in the range of 5 % < | DEV | ≤10 %, and 17 % were over 10 % deviations. In I-123, 41 % of the calibrators were within ±5 % and 29 % were in the range of 5 % < | DEV | ≤10 % and 30 % were over 10 %. The results have shown that such comparisons are necessary to improve the accuracy of the measurement and to identify radionuclide calibrators that are malfunctioning

  1. The Fission-Based  99Mo Production Process ROMOL-99 and Its Application to PINSTECH Islamabad

    Directory of Open Access Journals (Sweden)

    Rudolf Muenze

    2013-01-01

    Full Text Available An innovative process for fission based 99Mo production has been developed under Isotope Technologies Dresden (ITD GmbH (former Hans Wälischmiller GmbH (HWM, Branch Office Dresden, and its functionality has been tested and proved at the Pakistan Institute of Nuclear Science and Technology (PINSTECH, Islamabad. Targets made from uranium aluminum alloy clad with aluminum were irradiated in the core of Pakistan Research Reactor-1 (PARR-1. In the mean time more than 50 batches of fission molybdenum-99 (99Mo have been produced meeting the international purity/pharmacopoeia specifications using this ROMOL-99 process. The process is based on alkaline dissolution of the neutron irradiated targets in presence of NaNO3, chemically extracting the 99Mo from various fission products and purifying the product by column chromatography. This ROMOL-99 process will be described in some detail.

  2. Discordant results in Tc-99m tetrofosmin and Tc-99m sestamibi parathyroid scintigraphies; Resultados discordantes em cintilografias das paratireoides realizadas com tetrofosmin-99mTc e com sestamibi-99mTc

    Energy Technology Data Exchange (ETDEWEB)

    Duarte, Paulo Schiavom; Domingues, Fernanda C.; Santi Costa, Michele; Brandao, Cynthia; Oliveira, Marco A.C. de; Vieira, Jose G.H. [Fleury - Centro de Medicina Diagnostica, Sao Paulo, SP (Brazil)]. E-mail: paulo.duarte@fleury.com.br

    2007-10-15

    Parathyroid scintigraphies have been used to detect pathological parathyroid glands either before as well as after the parathyroid resection surgery in patients with hyperparathyroidism. One of the most utilized techniques to perform the studies is the double-phase images with Tc-99m sestamibi, which has been shown to be very accurate in the localization of enlarged parathyroid glands. Similar to Tc-99m sestamibi, Tc-99m tetrofosmin is a radiopharmaceutical initially developed to perform myocardial perfusion study that has been used to perform parathyroid scintigraphies. Although most of the papers suggest that the overall sensitivities of both radiopharmaceuticals are similar, there are some papers questioning the accuracy of Tc-99m tetrofosmin to detect abnormal parathyroid glands. In the present article, we report a case with discordant results by both methods. (author)

  3. Problems in clinical practice of domestic supply of 99Mo/99mTc. Current status and action plans on domestic production of 99Mo raw materials for medical use

    International Nuclear Information System (INIS)

    Nakamura, Yoshihide

    2012-01-01

    NRU in Canada and HFR in the Netherlands which had been producing the most important medical isotope, 99 Mo, were shut down in 2009-2010. As the production of more than 95% of global 99 Mo supply were performed in only five research reactors in the world including the two reactors mentioned above, these shutdowns resulted in global supply shortage of 99 Mo. Although the medical isotope crisis were alleviated after the two reactors returning to service, all of these five 99 Mo producing reactors are approximately 50 years old. Because the remaining life time of these reactors is not so long, the construction of new reactors or the development of new technologies to produce bulk 99 Mo, such as the neutron activation of 98 Mo in a reactor or charged particle reaction by accelerator, are proposed for the long-term security of supply of 99 Mo. The methods using the molybdenum target lead to much lower specific activity of 99 Mo compared to the production with fission method. The new chemical processing technologies, such as manufacturing 99m Tc-labeled radiopharmaceuticals from such low specific activity 99 Mo, are required for the development of domestic practical production of 99 Mo. (author)

  4. Conceptions of nuclear threshold status

    International Nuclear Information System (INIS)

    Quester, G.H.

    1991-01-01

    This paper reviews some alternative definitions of nuclear threshold status. Each of them is important, and major analytical confusions would result if one sense of the term is mistaken for another. The motives for nations entering into such threshold status are a blend of civilian and military gains, and of national interests versus parochial or bureaucratic interests. A portion of the rationale for threshold status emerges inevitably from the pursuit of economic goals, and another portion is made more attraction by the derives of the domestic political process. Yet the impact on international security cannot be dismissed, especially where conflicts among the states remain real. Among the military or national security motives are basic deterrence, psychological warfare, war-fighting and, more generally, national prestige. In the end, as the threshold phenomenon is assayed for lessons concerning the role of nuclear weapons more generally in international relations and security, one might conclude that threshold status and outright proliferation coverage to a degree in the motives for all of the states involved and in the advantages attained. As this paper has illustrated, nuclear threshold status is more subtle and more ambiguous than outright proliferation, and it takes considerable time to sort out the complexities. Yet the world has now had a substantial amount of time to deal with this ambiguous status, and this may tempt more states to exploit it

  5. Comparison of carrier-added [99mTc] EDTMP and carrier-free preparations of [99mTc] EDTMP and [99mTc] DPD

    International Nuclear Information System (INIS)

    Krcal, A.; Kletter, K.; Dudczak, R.; Pirich, C.; Mitterhauser, M.

    2002-01-01

    Full text: High uptake of bone-seeking radiopharmaceuticals in malignant bone lesions is a prerequisite for adequate bone scanning. Visual image analysis is impaired due to high soft-tissue activity with currently available [ 99m Tc]-EDTMP-kits. This study aimed to compare carrier-added [ 99m Tc]-EDTMP with carrier-free [ 99m Tc]-EDTMP and [ 99m Tc]-DPD preparations in clinical routine. 15 μg and 150 μg perrhenic acid respectively were added to [ 99m Tc]-pertechnetate (>6 GBq in 3 ml phys. saline). The solution was then transferred into a vial, containing 1 mg of EDTMP, 3.6 mg stannous(II)chloride and 10 mg ascorbic acid under inert conditions. Under vigorous stirring the reaction mixture was heated to 45 o C for 10 min. After cooling down to room temperature the labelling mixture was sterile filtrated (millipore 0.22 μm). Quality control was performed using radio-ITLC (Whatman SG; acetone or ethanol: R f perrhenate/pertechnetate 0.87, colloid/product 0.05; phys. saline: R f colloid 0.00, perrhenate/pertechnetate and product 0.9) allowing rapid and efficient assessment of the product. Carrier free [ 99m Tc]-EDTMP and [ 99m Tc]-DPD were prepared according to instructions of the manufacturer. Clinical studies were performed in 29 patients according to a routine bone scanning protocol by injecting 700-800 MBq of the respective tracer and whole body imaging 3 h thereafter. Radiochemical purity and radiochemical yield relied on various parameters such as concentration of carrier and reducing agent and reaction conditions (pH, reaction time, temperature). Means of the labelling yield were 22 % for the preparation using 150 μg of carrier (5 preparations), 80 % for the preparation using 15 μpg of carrier (10 preparations) and 91 % for the carrier free products (5 preparations). Radiochemical purity was >96 % in all experiments. Colloid was formed in very low amounts, and was completely removed by sterile filtration. In clinical studies quantitative analysis

  6. 99mTc-MAG3: can it be a viable alternative to 99mTc-DTPA ?

    International Nuclear Information System (INIS)

    Bal, C.S.; Padhy, A.K.; Nair, R.; Gopinath, P.G.

    1991-01-01

    The purpose of this study was to assess the potentials of 99m Tc MAG 3 to replace universally used 99m Tc-DTPA as a routine renal agent. Five patients with different nephrological problems were first studied with 99m Tc MAG 3 and then reinvestigated with 99m Tc-DTPA two to seven days later. Renal MAG 3 gamma camera images were found to be almost identical with those of 99m Tc-DTPA images except high hepatic and splenic uptake of the former compound in four out of five patients (80%) irrespective of kidney function. MAG 3 and DTPA renograms showed identical differential renal uptake function (r=0.87) with slightly higher uptake in right kidneys. Time to reach the peak correlated well (r=0.91). Time to reach half maximum renal activity was also found to be almost identical (r=0.97) for MAG 3 and DTPA. It was felt that the age old 99m Tc-DTPA is as good a compound as 99m Tc MAG 3 with regard to imaging and assessment of renal uptake, drainage and differential renal functions. 99m Tc-DTPA is much cheaper, readily available in India and stable to suit the logistics in a busy nuclear medicine department for routine renography. (author). 10 refs., 2 figs., 3 tabs

  7. A study on 99Tcm-citrate and 99Tcm (V)-DMSA imaging in the diagnosis of acute purulent osteoarthritis

    International Nuclear Information System (INIS)

    Wu Zhaozhong; Lin Wei; Wu Hengfu; Wu Changwei; Yuan Gewen; Fan Ziwen; Wu Boyi

    2003-01-01

    Objective: To assess the clinical diagnostic value of 99 Tc m -citrate and 99 Tc m (1/2ae)-dimercaptosuccinic acid (DMSA) imaging in the acute purulent osteoarthritis. Methods: Seventeen patients with confirmed acute purulent osteoarthritis and nineteen patients with non-purulent osteoarthritis were studied. In all patients, 99 Tc m -methylene diphosphonic acid (MDP), 99 Tc m -citrate and 99 Tc m (1/2ae)-DMSA imaging were sequentially performed and the images were analyzed semiquantitatively. Results: In the acute purulent osteoarthritis group, there were positive bonetactic accumulations at certain areas on the three kinds of imaging. In the non-purulent osteoarthritis group, 99 Tc m -MDP and 99 Tc m (1/2ae)-DMSA imaging showed clear bonetactic accumulation, but 99 Tc m -citrate imaging showed only light bonetactic accumulation in addition to the accumulations in soft tissue at certain areas. Lesion to nonlesion ratio (L/N=2.300±0.094) of acute purulent osteoarthritis was greater than that in non-purulent osteoarthritis group (1.298±0.054, P 99 Tc m -citrate imaging, and there was no significant difference between two groups on 99 Tc m (1/2ae)-DMSA imaging (L/N ratio of acute purulent osteoarthritis group was 3.495±0.180, and L/N ratio of non-purulent osteoarthritis group was 3.091±0.091, P>0.05). Conclusions: To diagnose the bone inflammation, 99 Tc m -citrate imaging coalesced with 99 Tc m -MDP or 99 Tc m (1/2ae)-DMSA imaging can help to evaluate the pathologic and physiologic progresses in bone inflammatory areas, at the same time , the information by 99 Tc m -citrate imaging is telling the actual inflammation areas, and that by 99 Tc m (1/2ae)-DMSA and 99 Tc m -MDP imaging is about the response to the increase of bone metabolism

  8. Comparison of Threshold Saccadic Vector Optokinetic Perimetry (SVOP) and Standard Automated Perimetry (SAP) in Glaucoma. Part II: Patterns of Visual Field Loss and Acceptability.

    Science.gov (United States)

    McTrusty, Alice D; Cameron, Lorraine A; Perperidis, Antonios; Brash, Harry M; Tatham, Andrew J; Agarwal, Pankaj K; Murray, Ian C; Fleck, Brian W; Minns, Robert A

    2017-09-01

    We compared patterns of visual field loss detected by standard automated perimetry (SAP) to saccadic vector optokinetic perimetry (SVOP) and examined patient perceptions of each test. A cross-sectional study was done of 58 healthy subjects and 103 with glaucoma who were tested using SAP and two versions of SVOP (v1 and v2). Visual fields from both devices were categorized by masked graders as: 0, normal; 1, paracentral defect; 2, nasal step; 3, arcuate defect; 4, altitudinal; 5, biarcuate; and 6, end-stage field loss. SVOP and SAP classifications were cross-tabulated. Subjects completed a questionnaire on their opinions of each test. We analyzed 142 (v1) and 111 (v2) SVOP and SAP test pairs. SVOP v2 had a sensitivity of 97.7% and specificity of 77.9% for identifying normal versus abnormal visual fields. SAP and SVOP v2 classifications showed complete agreement in 54% of glaucoma patients, with a further 23% disagreeing by one category. On repeat testing, 86% of SVOP v2 classifications agreed with the previous test, compared to 91% of SAP classifications; 71% of subjects preferred SVOP compared to 20% who preferred SAP. Eye-tracking perimetry can be used to obtain threshold visual field sensitivity values in patients with glaucoma and produce maps of visual field defects, with patterns exhibiting close agreement to SAP. Patients preferred eye-tracking perimetry compared to SAP. This first report of threshold eye tracking perimetry shows good agreement with conventional automated perimetry and provides a benchmark for future iterations.

  9. Rapid determination of 99Tc in environmental samples by high resolution ICP-MS coupled with on-line flow injection system

    International Nuclear Information System (INIS)

    Kim, C.K.; Kim, C.S.; Rho, B.H.; Lee, J.I.

    2002-01-01

    High resolution inductively coupled plasma mass spectrometry coupled with an on-line flow injection system (FI-HR-ICP-MS) was applied to determine the ultra-trace level 99 Tc in soil. The flow injection system (PrepLab TM ) was composed of two TEVA-Spec R resins, reduced remarkably the sample amounts and the analysis time, compared to the conventional analytical methods. In the flow injection system, Mo and Ru were sufficiently eliminated by using the flow injection system, with the decontamination factors of 1.6 x 10 4 and 9.9 x 10 5 , respectively. With the present method, it was possible to determine ultra-low level of 99 Tc in 3∼6 soil at 3-5 hours of analysis time per sample. The relative standard deviation for each sample was less than 4%. The detection limits for 99 Tc was 85 fg x ml -1 (0.05 mBq x ml -1 ), which was calculated from the three times standard deviation of the count rate of the blank. (author)

  10. Lock threshold deterioration induced by antenna vibration and signal coupling effects in hypersonic vehicle carrier tracking system of Ka band

    Directory of Open Access Journals (Sweden)

    Congying ZHU

    2018-04-01

    Full Text Available The envelope of a hypersonic vehicle is affected by severe fluctuating pressure, which causes the airborne antenna to vibrate slightly. This vibration mixes with the transmitted signals and thus introduces additional multiplicative phase noise. Antenna vibration and signal coupling effects as well as their influence on the lock threshold of the hypersonic vehicle carrier tracking system of the Ka band are investigated in this study. A vibration model is initially established to obtain phase noise in consideration of the inherent relationship between vibration displacement and electromagnetic wavelength. An analytical model of the Phase-Locked Loop (PLL, which is widely used in carrier tracking systems, is established. The coupling effects on carrier tracking performance are investigated and quantitatively analyzed by imposing the multiplicative phase noise on the PLL model. Simulation results show that the phase noise presents a Gaussian distribution and is similar to vibration displacement variation. A large standard deviation in vibration displacement exerts a significant effect on the lock threshold. A critical standard deviation is observed in the PLL of Binary Phase Shift Keying (BPSK and Quadrature Phase Shift Keying (QPSK signals. The effect on QPSK signals is more severe than that on BPSK signals. The maximum tolerable standard deviations normalized by the wavelength of the carrier are 0.04 and 0.02 for BPSK and QPSK signals, respectively. With these critical standard deviations, lock thresholds are increased from −12 and −4 dB to 3 and −2 dB, respectively. Keywords: Antenna vibration, Carrier tracking performance, Lock threshold, Phase locked loop, Tracking Telemetry and Command (TT&C signals

  11. 99mTc-ECD and 99mTc-HM-PAO SPECT in five patients with MELAS

    International Nuclear Information System (INIS)

    Katagiri, Shinako; Nishimaki, Hiroshi; Kitano, Masashi; Horiike, Shigeharu; Kan, Shinichi; Ishii, Katsumi; Matsubayashi, Takashi; Sakai, Fumihiko

    1998-01-01

    Cerebral perfusion was studied in five patients with mitochondrial encephalomyopathy with lactic acidosis and stroke-like episodes syndrome (MELAS), using single photon emission computed tomography (SPECT) with 99m Tc-ethyl cysteinate dimer ( 99m Tc-ECD) or 99m Tc-hexamethyl propyleneamine oxime ( 99m Tc-HM-PAO). In four cases, regional cerebral blood flow (rCBF) was evaluated by the method reported by Mastuda et al. Immediately after the stroke-like episodes, accumulation of the tracer was relatively increased in the temporooccipital lobe, and also increased rCBF was shown in the same area. However, the region showed decreased radioactivity at the chronic stage, and rCBF decreased also. These findings are consistent with positron emission tomography (PET) at the acute stage and autopsy. 99m Tc-ECD SPECT and 99m Tc-HM-PAO SPECT may be useful in the diagnosis and assessment of the progress of the MELAS. (author)

  12. Determination of radionuclidic impurities in 99mTceluate from 99Mo/99mTc generator for quality control

    DEFF Research Database (Denmark)

    Hou, Xiaolin

    2017-01-01

    , 89Sr and 90Sr. Radioactive decay for removal of 99mTc, ion exchange and extraction chromatography for removal of 99Mo and 99Tc are effective for separation of interferences. Gamma spectrometry, LSC with alpha/beta discrimination, and Cherenkov counting using LSC are sensitive methods for measurement...... of the impurity radionuclides. The detection limits of this method are well meet the requirement of the quality control according to the limitation of the pharmacopoeia....

  13. Experimental study of 99Tcm-HL91 and 99Tcm-MIBI in mice bearing Lewis lung cancer

    International Nuclear Information System (INIS)

    Han Chunqi; Li Yaming; Ren Yangang; Yi Lijie

    2000-01-01

    Objective: To evaluate the ability of detecting lung cancer by 99 Tc m -HL91 and 99 Tc m -MIBI in mice bearing Lewis lung cancer. Methods: Four model mice underwent whole body planar imaging at 2 h, 4 h after injection of 99 Tc m -MIBI; four mice underwent whole body planar imaging at 2 h and 4 h after injection of 99 Tc m -HL91, and the mice of the 99 Tc m -HL91 group were then killed, the tumor, blood and organs were removed, weighted and the radioactivity was measured. ROIs were drawn around the tumor, head and chest in whole body planar images, and radioactivity ratios of tumor to head (T/H), chest (T/C) and contralateral limbs (T/L) were calculated. Results: No significant tumor radioactivity in 2 h and 4 h images of 99 Tc m -MIBI mice (T/C: 0.20 +- 0.08 and 0.14 +- 0.07) was found; increased tumor radioactivity was identified in images of 99 Tc m -HL91 mice (T/C: 3.25 +- 1.25 and 2.44 +- 1.07), and there was significant difference (t = 4.8 - 7.5, P 99 Tc m -HL91 in tumor tissue of mice is higher and clearance rate is slower. 99 Tc m -HL91 is a valuable tumor imaging agent for clinical diagnosis for the cancer

  14. Threshold Concepts in Finance: Student Perspectives

    Science.gov (United States)

    Hoadley, Susan; Kyng, Tim; Tickle, Leonie; Wood, Leigh N.

    2015-01-01

    Finance threshold concepts are the essential conceptual knowledge that underpin well-developed financial capabilities and are central to the mastery of finance. In this paper we investigate threshold concepts in finance from the point of view of students, by establishing the extent to which students are aware of threshold concepts identified by…

  15. Preparation of 99Mo for 99mTc generators and the issue of further development. A survey report

    International Nuclear Information System (INIS)

    Malek, Z.

    1998-01-01

    The following topics are dealt with: World production of Mo-99 for technetium generators; Typical procedures for the preparation of Mo-99; Current and expected decline in the production of Mo-99; and Directions of further development (Water reactors-irradiation systems for the preparation of Mo-99; Homogeneous reactor systems for the preparation of Mo-99 based on molten salts; Systems with accelerators; Thermal processes for the reprocessing of irradiated target material). (P.A.)

  16. Thresholding magnetic resonance images of human brain

    Institute of Scientific and Technical Information of China (English)

    Qing-mao HU; Wieslaw L NOWINSKI

    2005-01-01

    In this paper, methods are proposed and validated to determine low and high thresholds to segment out gray matter and white matter for MR images of different pulse sequences of human brain. First, a two-dimensional reference image is determined to represent the intensity characteristics of the original three-dimensional data. Then a region of interest of the reference image is determined where brain tissues are present. The non-supervised fuzzy c-means clustering is employed to determine: the threshold for obtaining head mask, the low threshold for T2-weighted and PD-weighted images, and the high threshold for T1-weighted, SPGR and FLAIR images. Supervised range-constrained thresholding is employed to determine the low threshold for T1-weighted, SPGR and FLAIR images. Thresholding based on pairs of boundary pixels is proposed to determine the high threshold for T2- and PD-weighted images. Quantification against public data sets with various noise and inhomogeneity levels shows that the proposed methods can yield segmentation robust to noise and intensity inhomogeneity. Qualitatively the proposed methods work well with real clinical data.

  17. Synthesis and irradiation of titanium molybdates used as matrices of the {sup 99} Mo/ {sup 99m} Tc generators; Sintesis e irradiacion de molibdatos de titanio utilizados como matrices de los generadores de {sup 99} Mo/ {sup 99m} Tc

    Energy Technology Data Exchange (ETDEWEB)

    Diaz V, H. [Facultad de Quimica, UAEM 50000 Toluca, Estado de Mexico (Mexico); Monroy G, F. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    The {sup 99m} Tc is the radioisotope but used in nuclear medicine. Commercially it takes place starting from generators of {sup 99} Mo/{sup 99m} Tc, composed by a chromatography column padded of aluminium oxide of aluminum, where it is deposited the {sup 99} Mo, product of the fission of the {sup 235} U adsorbed and eluted, by means of a saline solution, in form of {sup 99m} TcO{sub 4}{sup -}. The production of {sup 99} Mo as a result of the fission, imposes radiochemical separations that generate significant quantities of radioactive waste of medium activity, and inflict elaborated radiochemical manipulation. Due to this, its have been carried out intense investigations to substitute the {sup 99} Mo fission product, by chemical compounds that produce {sup 99} Mo via the reaction {sup 98} Mo(n, {gamma}){sup 99} Mo. Presently work intends the use of gels of titanium molybdates like matrices of these generators. Titanium molybdates were synthesized starting from solutions TiCl{sub 3} and ammonium molybdates and it was studied the effect of the final pH of the gels, the concentration of the Ti{sup +3} and the influence of the laundry of these on the acting of generators. The best efficiencies and chemical purity, radiochemical and radionuclides of the gels like matrices of generators {sup 99} Mo/{sup 99m} Tc were gotten with the washed gel, elaborated with the solution of TiCI{sub 3} 0.35M, and to a final pH of 5.9 (Author)

  18. Near threshold fatigue testing

    Science.gov (United States)

    Freeman, D. C.; Strum, M. J.

    1993-01-01

    Measurement of the near-threshold fatigue crack growth rate (FCGR) behavior provides a basis for the design and evaluation of components subjected to high cycle fatigue. Typically, the near-threshold fatigue regime describes crack growth rates below approximately 10(exp -5) mm/cycle (4 x 10(exp -7) inch/cycle). One such evaluation was recently performed for the binary alloy U-6Nb. The procedures developed for this evaluation are described in detail to provide a general test method for near-threshold FCGR testing. In particular, techniques for high-resolution measurements of crack length performed in-situ through a direct current, potential drop (DCPD) apparatus, and a method which eliminates crack closure effects through the use of loading cycles with constant maximum stress intensity are described.

  19. Radiopharmaceuticals to 99mTc

    International Nuclear Information System (INIS)

    Leon Cabana, Alba

    1994-01-01

    Studies about 99m Tc had demonstrated that have favorable properties for support diagnostic proceedings in nuclear medicine. This physical and chemical properties used for obtain another radiopharmaceuticals have been employed through re actives kits labelled with Tc 99m . A brief description was given about 99m utilities in diagnostic techniques such as endothelium reticular system,renal and hepatic studies,bone scintillators,cardiac diagnostic and cerebral perfusion

  20. Imaging of irradiated liver with Tc-99m-sulfur colloid and Tc-99m-IDA

    International Nuclear Information System (INIS)

    Gelfand, M.J.; Saha, S.; Aron, B.S.

    1981-01-01

    In three cases, irradiated regions of liver failed to concentrate Tc-99m-sulfur colloid. In two of these three, imaging with Tc-99m-acetanilide iminodiacetic acid (IDA) agents within five days showed near normal hepatic uptake of this hepatobiliary imaging agent. The hepatic parenchymal cells may be imaged with Tc-99m-IDA in some irradiated regions of liver, despite loss of reticuloendothelial cell function