WorldWideScience

Sample records for stage gas gun

  1. A trial of the three-stage light-gas gun with a preheating stage

    Science.gov (United States)

    Kondo, K.; Hironaka, Y.; Ito, H.; Sugiura, H.; Ozaki, S.; Takeba, A.; Katayama, M.

    1996-05-01

    A three-stage light-gas gun having a preheating and filling stage of gas was designed and installed in order to independently regulate the initial energy of the light gas. Although the operation and the performance of gun become so complicated, the computer simulations for the gun indicate many advantages, e.g., a scale of the gun much decreases in comparison with a conventional two-stage light-gas gun at the same value of the maximum obtainable projectile velocity.

  2. Repetitive, small-bore two-stage light gas gun

    International Nuclear Information System (INIS)

    Combs, S.K.; Foust, C.R.; Fehling, D.T.; Gouge, M.J.; Milora, S.L.

    1991-01-01

    A repetitive two-stage light gas gun for high-speed pellet injection has been developed at Oak Ridge National Laboratory. In general, applications of the two-stage light gas gun have been limited to only single shots, with a finite time (at least minutes) needed for recovery and preparation for the next shot. The new device overcomes problems associated with repetitive operation, including rapidly evacuating the propellant gases, reloading the gun breech with a new projectile, returning the piston to its initial position, and refilling the first- and second-stage gas volumes to the appropriate pressure levels. In addition, some components are subjected to and must survive severe operating conditions, which include rapid cycling to high pressures and temperatures (up to thousands of bars and thousands of kelvins) and significant mechanical shocks. Small plastic projectiles (4-mm nominal size) and helium gas have been used in the prototype device, which was equipped with a 1-m-long pump tube and a 1-m-long gun barrel, to demonstrate repetitive operation (up to 1 Hz) at relatively high pellet velocities (up to 3000 m/s). The equipment is described, and experimental results are presented. 124 refs., 6 figs., 5 tabs

  3. Design of a Two-Stage Light Gas Gun for Muzzle Velocities of 10 - 11 kms

    Science.gov (United States)

    Bogdanoff, David W.

    2016-01-01

    Space debris poses a major risk to spacecraft. In low earth orbit, impact velocities can be 10 11 kms and as high as 15 kms. For debris shield design, it would be desirable to be able to launch controlled shape projectiles to these velocities. The design of the proposed 10 11 kmsec gun uses, as a starting point, the Ames 1.280.22 two stage gun, which has achieved muzzle velocities of 10 11.3 kmsec. That gun is scaled up to a 0.3125 launch tube diameter. The gun is then optimized with respect to maximum pressures by varying the pump tube length to diameter ratio (LD), the piston mass and the hydrogen pressure. A pump tube LD of 36.4 is selected giving the best overall performance. Piezometric ratios for the optimized guns are found to be 2.3, much more favorable than for more traditional two stage light gas guns, which range from 4 to 6. The maximum powder chamber pressures are 20 to 30 ksi. To reduce maximum pressures, the desirable range of the included angle of the cone of the high pressure coupling is found to be 7.3 to 14.6 degrees. Lowering the break valve rupture pressure is found to lower the maximum projectile base pressure, but to raise the maximum gun pressure. For the optimized gun with a pump tube LD of 36.4, increasing the muzzle velocity by decreasing the projectile mass and increasing the powder loads is studied. It appears that saboted spheres could be launched to 10.25 and possibly as high as 10.7 10.8 kmsec, and that disc-like plastic models could be launched to 11.05 kms. The use of a tantalum liner to greatly reduce bore erosion and increase muzzle velocity is discussed. With a tantalum liner, CFD code calculations predict muzzle velocities as high as 12 to 13 kms.

  4. Compressed gas combined single- and two-stage light-gas gun

    Science.gov (United States)

    Lamberson, L. E.; Boettcher, P. A.

    2018-02-01

    With more than 1 trillion artificial objects smaller than 1 μm in low and geostationary Earth orbit, space assets are subject to the constant threat of space debris impact. These collisions occur at hypervelocity or speeds greater than 3 km/s. In order to characterize material behavior under this extreme event as well as study next-generation materials for space exploration, this paper presents a unique two-stage light-gas gun capable of replicating hypervelocity impacts. While a limited number of these types of facilities exist, they typically are extremely large and can be costly and dangerous to operate. The design presented in this paper is novel in two distinct ways. First, it does not use a form of combustion in the first stage. The projectile is accelerated from a pressure differential using air and inert gases (or purely inert gases), firing a projectile in a nominal range of 1-4 km/s. Second, the design is modular in that the first stage sits on a track sled and can be pulled back and used in itself to study lower speed impacts without any further modifications, with the first stage piston as the impactor. The modularity of the instrument allows the ability to investigate three orders of magnitude of impact velocities or between 101 and 103 m/s in a single, relatively small, cost effective instrument.

  5. Two-stage plasma gun based on a gas discharge with a self-heating hollow emitter.

    Science.gov (United States)

    Vizir, A V; Tyunkov, A V; Shandrikov, M V; Oks, E M

    2010-02-01

    The paper presents the results of tests of a new compact two-stage bulk gas plasma gun. The plasma gun is based on a nonself-sustained gas discharge with an electron emitter based on a discharge with a self-heating hollow cathode. The operating characteristics of the plasma gun are investigated. The discharge system makes it possible to produce uniform and stable gas plasma in the dc mode with a plasma density up to 3x10(9) cm(-3) at an operating gas pressure in the vacuum chamber of less than 2x10(-2) Pa. The device features high power efficiency, design simplicity, and compactness.

  6. Construction and characterization of a single stage dual diaphragm gas gun

    Science.gov (United States)

    Helminiak, Nathaniel Steven

    In the interest of studying the propagation of shock waves, this work sets out to design, construct, and characterize a pneumatic accelerator that performs high-velocity flyer plate impact tests. A single stage gas gun with a dual diaphragm breach allows for a non-volatile, reliable experimental testing platform for shock phenomena. This remotely operated gas gun utilizes compressed nitrogen to launch projectiles down a 14 foot long, 2 inch diameter bore barrel, which subsequently impacts a target material of interest. A dual diaphragm firing mechanism allows the 4.5 liter breech to reach a total pressure differential of 10ksi before accelerating projectiles to velocities as high as 1,000 m/s (1570-2240 mph). The projectile's velocity is measured using a series of break pin circuits. The target response can be measured with Photon Doppler Velocimetry (PDV) and/or stress gauge system. A vacuum system eliminates the need for pressure relief in front of the projectile, while additionally allowing the system to remain closed over the entire firing cycle. Characterization of the system will allow for projectile speed to be estimated prior to launching based on initial breach pressure.

  7. Hugoniot measurements in vanadium using the LNL two-stage light-gas gun

    International Nuclear Information System (INIS)

    Gathers, G.R.; Mitchell, A.C.; Holmes, N.C.

    1983-01-01

    Hugoniot measurements on vanadium have been made using the LLNL two-stage light-gas gun. The direct collision method with electrical pins and a tantalum flyer accelerated to 6.28 km/s was used. Alt'shuler, et. al., have reported Hugoniot measurements in vanadium using explosives and the impedance match method. They reported a kink in the U/sub s/ - U/sub p/ relationship at 183 GPa, and attribute it to electronic transitions. The upper portion of their curve is based on a single point at 339 GPa. The present work was performed to further investigate the equation-of-state in the high-pressure range

  8. Study and development of a two-stage light gas gun

    International Nuclear Information System (INIS)

    Lezaud, Jean-Michel

    1976-01-01

    After recalling the definition of principal dimensional internal characteristics of a light gas gun studied and developed at Commissariat a l'Energie Atomique, we present the interior ballistics calculation systems in fixed working conditions: these conditions permit to accelerate a 400 g projectile to 6500 m/s speed. About these conditions is studied the influence of some operating parameters: weight of piston, initial pressure of hydrogen, breaking pressure of diaphragms. Afterwards is presented a study of dynamic axial stresses. The consequence of these stresses in certain cross sections of gun has led to conceive the original solution of gun called gun sliding launching tube. At last, some special points appropriated to operating or working methods (optimisation of convergent, extrusion of piston, failure of diaphragms, position of target, circuits of fluids) are presented. (author) [fr

  9. Use of a Tantalum Liner to Reduce Bore Erosion and Increase Muzzle Velocity in Two-Stage Light Gas Guns

    Science.gov (United States)

    Bogdanoff, David W.

    2015-01-01

    Muzzle velocities and gun erosion predicted by earlier numerical simulations of two stage light gas guns with steel gun tubes were in good agreement with experimental values. In a subsequent study, simulations of high performance shots were repeated with rhenium (Re) gun tubes. Large increases in muzzle velocity (2 - 4 km/sec) were predicted for Re tubes. In addition, the hydrogen-produced gun tube erosion was, in general, predicted to be zero with Re tubes. Tantalum (Ta) has some mechanical properties superior to those of Re. Tantalum has a lower modulus of elasticity than Re for better force transmission from the refractory metal liner to an underlying thick wall steel tube. Tantalum also has greater ductility than Re for better survivability during severe stress/strain cycles. Also, tantalum has been used as a coating or liner in military powder guns with encouraging results. Tantalum has, however, somewhat inferior thermal properties to those of rhenium, with a lower melting point and lower density and thermal conductivity. The present study was undertaken to see to what degree the muzzle velocity gains of rhenium gun tubes (over steel tubes) could be achieved with tantalum gun tubes. Nine high performance shots were modeled with a new version of our CFD gun code for steel, rhenium and tantalum gun tubes. For all except the highest velocity shot, the results with Ta tubes were nearly identical with those for Re tubes. Even for the highest velocity shot, the muzzle velocity gain over a steel tube using Ta was 82% of the gain obtained using Re. Thus, the somewhat inferior thermal properties of Ta (when compared to those of Re) translate into only very slightly poorer overall muzzle velocity performance. When this fact is combined with the superior mechanical properties of Ta and the encouraging performance of Ta liners/coatings in military powder guns, tantalum is to be preferred over Re as a liner/coating material for two stage light gas guns to increase muzzle

  10. High Velocity Gas Gun

    Science.gov (United States)

    1988-01-01

    A video tape related to orbital debris research is presented. The video tape covers the process of loading a High Velocity Gas Gun and firing it into a mounted metal plate. The process is then repeated in slow motion.

  11. The Dynamics of Projectiles Launched by a Two-Stage Light-Gas Gun

    Science.gov (United States)

    1991-11-01

    7 2.6 Pressure Blow-By ........................................................................ 7 2.7 Ballating ...The relatively snug fit of the projectile in the bore also prevents the model from ballating as it travels down the barrel. The friction between the...and allowing more freedom for the unwanted ballating motion. The design of the model/sabot and the gas gun attempts to satisfy dual and often

  12. Recent developments of a two-stage light gas gun for pellet injection

    International Nuclear Information System (INIS)

    Reggiori, A.

    1984-01-01

    A report is given on a two-stage pneumatic gun operated with ambient air as first stage driver which has been built and tested. Cylindrical polyethylene pellets of 1 mm diameter and 1 mm length have been launched at velocities up to 1800 m/s, with divergence angles of the pellet trajectory less than 1 0 . It is possible to optimize the pressure pulse for pellets of different masses, simply changing the mass of the piston and/or the initial pressures in the second stage. (author)

  13. Acceleration of small, light projectiles (including hydrogen isotopes) to high speeds using a two-stage light gas gun

    International Nuclear Information System (INIS)

    Combs, S.K.; Foust, C.R.; Gouge, M.J.; Milora, S.L.

    1989-01-01

    Small, light projectiles have been accelerated to high speeds using a two-stage light gas gun at Oak Ridge National Laboratory. With 35-mg plastic projectiles (4 mm in diameter), speeds of up to 4.5 km/s have been recorded. The ''pipe gun'' technique for freezing hydrogen isotopes in situ in the gun barrel has been used to accelerate deuterium pellets (nominal diameter of 4 mm) to velocities of up to 2.85 km/s. The primary application of this technology is for plasma fueling of fusion devices via pellet injection of hydrogen isotopes. Conventional pellet injectors are limited to pellet speeds in the range 1-2 km/s. Higher velocities are desirable for plasma fueling applications, and the two-stage pneumatic technique offers performance in a higher velocity regime. However, experimental results indicate that the use of sabots to encase the cryogenic pellets and protect them for the high peak pressures will be required to reliably attain intact pellets at speeds of ∼3 km/s or greater. In some limited tests, lithium hydride pellets were accelerated to speeds of up to 4.2 km/s. Also, repetitive operation of the two-stage gun (four plastic pellets fired at ∼0.5 Hz) was demonstrated for the first time in preliminary tests. The equipment and operation are described, and experimental results and some comparisons with a theoretical model are presented. 17 refs., 6 figs., 2 tabs

  14. Development of a two-stage light gas gun to accelerate hydrogen pellets to high speeds for plasma fueling applications

    International Nuclear Information System (INIS)

    Combs, S.K.; Milora, S.L.; Foust, C.R.; Gouge, M.J.; Fehling, D.T.; Sparks, D.O.

    1988-01-01

    The development of a two-stage light gas gun to accelerate hydrogen isotope pellets to high speeds is under way at Oak Ridge National Laboratory. High velocities (>2 km/s) are desirable for plasma fueling applications, since the faster pellets can penetrate more deeply into large, hot plasmas and deposit atoms of fuel directly in a larger fraction of the plasma volume. In the initial configuration of the two-stage device, a 2.2-l volume (/ 3 for frozen hydrogen isotopes). However, the use of sabots to encase and protect the cryogenic pellets from the high peak pressures will probably be required to realize speeds of ∼3 km/s or greater. The experimental plan includes acceleration of hydrogen isotopes as soon as the gun geometry and operating parameters are optimized; theoretical models are being used to aid in this process. The hardware is being designed to accommodate repetitive operation, which is the objective of this research and is required for future applications. 25 refs., 6 figs., 1 tab

  15. High Precision Motion Control System for the Two-Stage Light Gas Gun at the Dynamic Compression Sector

    Science.gov (United States)

    Zdanowicz, E.; Guarino, V.; Konrad, C.; Williams, B.; Capatina, D.; D'Amico, K.; Arganbright, N.; Zimmerman, K.; Turneaure, S.; Gupta, Y. M.

    2017-06-01

    The Dynamic Compression Sector (DCS) at the Advanced Photon Source (APS), located at Argonne National Laboratory (ANL), has a diverse set of dynamic compression drivers to obtain time resolved x-ray data in single event, dynamic compression experiments. Because the APS x-ray beam direction is fixed, each driver at DCS must have the capability to move through a large range of linear and angular motions with high precision to accommodate a wide variety of scientific needs. Particularly challenging was the design and implementation of the motion control system for the two-stage light gas gun, which rests on a 26' long structure and weighs over 2 tons. The target must be precisely positioned in the x-ray beam while remaining perpendicular to the gun barrel axis to ensure one-dimensional loading of samples. To accommodate these requirements, the entire structure can pivot through 60° of angular motion and move 10's of inches along four independent linear directions with 0.01° and 10 μm resolution, respectively. This presentation will provide details of how this system was constructed, how it is controlled, and provide examples of the wide range of x-ray/sample geometries that can be accommodated. Work supported by DOE/NNSA.

  16. Simple light gas guns for hypervelocity studies

    International Nuclear Information System (INIS)

    Combs, S.K.; Haselton, H.H.; Milora, S.L.

    1990-01-01

    Two-stage light guns are used extensively in hypervelocity research. The applications of this technology include impact studies and special materials development. Oak Ridge National Laboratory (ORNL) has developed two-stage guns that accelerate small projectiles (4-mm nominal diameter) to velocities of up to ∼5 km/s. These guns are relatively small and simple (thus, easy to operate), allowing a significant number of test shots to be carried out and data accumulated in a short time. Materials that have been used for projectiles include plastics, frozen isotopes of hydrogen, and lithium hydride. One gun has been used to demonstrate repetitive operation at a rate of 0.7 Hz; and, with a few design improvements, it appears capable of performing at firing frequencies of 1--2 Hz. A schematic of ORNL two-stage device is shown below. Unlike most such devices, no rupture disks are used. Instead, a fast valve (high-flow type) initiates the acceleration process in the first stage. Projectiles can be loaded into the gun breech via the slide mechanism; this action has been automated which allows repetitive firing. Alternatively, the device is equipped with ''pipe gun'' apparatus in which gas can be frozen in situ in the gun barrel to form the projectile. This equipment operates with high reliability and is well suited for small-scale testing at high velocity. 17 refs., 6 figs., 2 tabs

  17. Modeling internal ballistics of gas combustion guns.

    Science.gov (United States)

    Schorge, Volker; Grossjohann, Rico; Schönekess, Holger C; Herbst, Jörg; Bockholdt, Britta; Ekkernkamp, Axel; Frank, Matthias

    2016-05-01

    Potato guns are popular homemade guns which work on the principle of gas combustion. They are usually constructed for recreational rather than criminal purposes. Yet some serious injuries and fatalities due to these guns are reported. As information on the internal ballistics of homemade gas combustion-powered guns is scarce, it is the aim of this work to provide an experimental model of the internal ballistics of these devices and to investigate their basic physical parameters. A gas combustion gun was constructed with a steel tube as the main component. Gas/air mixtures of acetylene, hydrogen, and ethylene were used as propellants for discharging a 46-mm caliber test projectile. Gas pressure in the combustion chamber was captured with a piezoelectric pressure sensor. Projectile velocity was measured with a ballistic speed measurement system. The maximum gas pressure, the maximum rate of pressure rise, the time parameters of the pressure curve, and the velocity and path of the projectile through the barrel as a function of time were determined according to the pressure-time curve. The maximum gas pressure was measured to be between 1.4 bar (ethylene) and 4.5 bar (acetylene). The highest maximum rate of pressure rise was determined for hydrogen at (dp/dt)max = 607 bar/s. The muzzle energy was calculated to be between 67 J (ethylene) and 204 J (acetylene). To conclude, this work provides basic information on the internal ballistics of homemade gas combustion guns. The risk of injury to the operator or bystanders is high, because accidental explosions of the gun due to the high-pressure rise during combustion of the gas/air mixture may occur.

  18. Hypervelocity Code to Design Light Gas Guns to Achieve 10km/s+

    Data.gov (United States)

    National Aeronautics and Space Administration — Create a validated three stage light gas gun (3SLGG) code, running over 400 iterations providing the optimal geometries to enable the design, build and safe...

  19. Gas powered fluid gun with recoil mitigation

    Science.gov (United States)

    Grubelich, Mark C; Yonas, Gerold

    2013-11-12

    A gas powered fluid gun for propelling a stream or slug of a fluid at high velocity toward a target. Recoil mitigation is provided that reduces or eliminates the associated recoil forces, with minimal or no backwash. By launching a quantity of water in the opposite direction, net momentum forces are reduced or eliminated. Examples of recoil mitigation devices include a cone for making a conical fluid sheet, a device forming multiple impinging streams of fluid, a cavitating venturi, one or more spinning vanes, or an annular tangential entry/exit.

  20. Cylinder expansion test and gas gun experiment comparison

    Energy Technology Data Exchange (ETDEWEB)

    Harrier, Danielle [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-30

    This is a summer internship presentation by the Hydro Working Group at Los Alamos National Laboratory (LANL) and goes into detail about their cylinder expansion test and gas gun experiment comparison. Specifically, the gas gun experiment is detailed along with applications, the cylinder expansion test is detailed along with applications, there is a comparison of the methods with pros and cons and limitations listed, the summer project is detailed, and future work is talked about.

  1. Gas Gun Model and Comparison to Experimental Performance of Pipe Guns Operating with Light Propellant Gases and Large Cryogenic Pellets

    Energy Technology Data Exchange (ETDEWEB)

    Reed, J. R. [University of Tennessee, Knoxville (UTK); Carmichael, J. R. [Fermi National Accelerator Laboratory (FNAL); Gebhart, T. E. [University of Florida, Gainesville; Combs, Stephen Kirk [ORNL; Baylor, Larry R. [ORNL; Rasmussen, David A. [ORNL; Meitner, Steven J. [ORNL; Lyttle, Mark S. [ORNL

    2017-10-01

    Injection of multiple large (~10 to 30 mm diameter) shattered pellets into ITER plasmas is presently part of the scheme planned to mitigate the deleterious effects of disruptions on the vessel components. To help in the design and optimize performance of the pellet injectors for this application, a model referred to as “the gas gun simulator” has been developed and benchmarked against experimental data. The computer code simulator is a Java program that models the gas-dynamics characteristics of a single-stage gas gun. Following a stepwise approach, the code utilizes a variety of input parameters to incrementally simulate and analyze the dynamics of the gun as the projectile is launched down the barrel. Using input data, the model can calculate gun performance based on physical characteristics, such as propellant-gas and fast-valve properties, barrel geometry, and pellet mass. Although the model is fundamentally generic, the present version is configured to accommodate cryogenic pellets composed of H2, D2, Ne, Ar, and mixtures of them and light propellant gases (H2, D2, and He). The pellets are solidified in situ in pipe guns that consist of stainless steel tubes and fast-acting valves that provide the propellant gas for pellet acceleration (to speeds ~200 to 700 m/s). The pellet speed is the key parameter in determining the response time of a shattered pellet system to a plasma disruption event. The calculated speeds from the code simulations of experiments were typically in excellent agreement with the measured values. With the gas gun simulator validated for many test shots and over a wide range of physical and operating parameters, it is a valuable tool for optimization of the injector design, including the fast valve design (orifice size and volume) for any operating pressure (~40 bar expected for the ITER application) and barrel length for any pellet size (mass, diameter, and length). Key design parameters and proposed values for the pellet injectors for

  2. Numerical Evaluation of a Light-Gas Gun Facility for Impact Test

    Directory of Open Access Journals (Sweden)

    C. Rahner

    2014-01-01

    Full Text Available Experimental tests which match the application conditions might be used to properly evaluate materials for specific applications. High velocity impacts can be simulated using light-gas gun facilities, which come in different types and complexities. In this work different setups for a one-stage light-gas gun facility have been numerically analyzed in order to evaluate their suitability for testing materials and composites used as armor protection. A maximal barrel length of 6 m and a maximal reservoir pressure of a standard industrial gas bottle (20 MPa were chosen as limitations. The numerical predictions show that it is not possible to accelerate the projectile directly to the desired velocity with nitrogen, helium, or hydrogen as propellant gas. When using a sabot corresponding to a higher bore diameter, the necessary velocity is achievable with helium and hydrogen gases.

  3. Light Gas Gun Testing of PVDF by Undergraduates

    Science.gov (United States)

    Hyde, Truell; Matthews, Lorin; Carmona-Reyes, Jorge

    Orbital debris has been a problem for spacecraft in orbit about the earth since the dawn of the space age. As such, a vital part of the launch preparation process for any space mission includes development of computer models, space debris tracking devices, in-situ dust detectors, and research into advanced shielding processes. It is necessary to reproduce the space environment in the lab in order to fully understand the physics behind the damage that space debris can cause. To this end, the Center for Astrophysics, Space Physics and Engineering Research (CASPER) employs a one-stage Light Gas Gun (LGG) for low velocity impact studies. This instrument has proven to be an ideal environment for introducing undergraduates to an experimental lab setting as well as to the field of orbital debris. This paper will discuss the advantages of including undergraduates in the lab early in their career. Recent data collected by undergraduates and technical interns using the CASPER LGG to determine the basic capabilities of Polyvinylidene Difluoride (PVDF) as an in-situ dust detector device will be examined. This type of device was chosen in part because it can easily be assembled and monitored by undergraduate students. Long-term educational goals of the project will also be discussed.

  4. Tailored ramp wave generation in gas gun experiments

    Directory of Open Access Journals (Sweden)

    Cotton Matthew

    2015-01-01

    Full Text Available Gas guns are traditionally used as platforms to introduce a planar shock wave to a material using plate impact methods, generating states on the Hugoniot. The ability to deliver a ramp wave to a target during a gas gun experiment enables access to different regions of the equation-of-state surface, making it a valuable technique for characterising material behaviour. Previous techniques have relied on the use of multi-material impactors to generate a density gradient, which can be complex to manufacture. In this paper we describe the use of an additively manufactured steel component consisting of an array of tapered spikes which can deliver a ramp wave over ∼ 2 μs. The ability to tailor the input wave by varying the component design is discussed, an approach which makes use of the design freedom offered by additive manufacturing techniques to rapidly iterate the spike profile. Results from gas gun experiments are presented to evaluate the technique, and compared with 3D hydrodynamic simulations.

  5. Guns and High Gas Output Devices Panel: Introduction

    Science.gov (United States)

    Simmons, Ronald L.; Kaste, Pamela J.

    2000-01-01

    A new panel known as the Guns and High Gas Output Panel was organized in 1999 under the auspices of the JANNAF Propellant and Characterization SubCommittee (PDCS). This is an introduction to our first meeting, purpose of the panel, and the scope of activities to be covered. The primary purpose of the panel is very simple: to provide a single focal point for interfacing Government Laboratories (Department of Defense and Department of Energy) and commercial industry researchers to share R&D activities and findings (i.e. facilitate the exchange of information) specifically aimed at gun-launched propulsion and high-gas output devices (gas generators and air bag inflators). Specific areas of interest included in the Panel's scope (and the Technical Data Base) are the following: (1) new propellant formulations and chemistry, (2) new ingredients, (3) ballistic effects of the new formulations and ingredients, (4) new processing methods unique to gun propellants, (5) thermochemistry of new ingredients, (6) unique physical and mechanical properties, (7) burning rates of new propellants and small scale closed bomb testing, (8) plasma effects on the propellant, and (9) unique safety and insensitive munitions properties.

  6. Chlorobenzylidenemalonitrile Gas Exposure from A Novelty Personal-Protection Gun

    Directory of Open Access Journals (Sweden)

    Dong, Christopher

    2007-05-01

    Full Text Available We present an unusual case of chlorobenzylidenemalonitrile (CS tear-gas exposure from the unwitting discharge of a personal-protection handgun loaded with CS gas. The gun was in a bag of toys purchased from a local thrift store and was discharged by a child. The responding paramedic presumptively identified the substance as CS based solely on personal experience. This recognition led to suboptimal field management of the incident with the paramedic failing to follow the standard operating procedures for an unknown chemical exposure. As this was a benign agent, there were no serious consequences. This case highlights the pre-hospital and emergency department challenges associated with the management of an unknown chemical exposure and the potential consequences if the chemical is a toxic substance. A methodical approach following established protocols can reduce the potential for negative outcomes. Review of the literature found no other report of CS gas exposure from such a personal-protection weapon.

  7. Chlorobenzylidenemalonitrile Gas Exposure from A Novelty Personal-Protection Gun

    Science.gov (United States)

    Dong, Christopher; de la Garza, Albert

    2007-01-01

    We present an unusual case of chlorobenzylidenemalonitrile (CS) tear-gas exposure from the unwitting discharge of a personal-protection handgun loaded with CS gas. The gun was in a bag of toys purchased from a local thrift store and was discharged by a child. The responding paramedic presumptively identified the substance as CS based solely on personal experience. This recognition led to suboptimal field management of the incident with the paramedic failing to follow the standard operating procedures for an unknown chemical exposure. As this was a benign agent, there were no serious consequences. This case highlights the pre-hospital and emergency department challenges associated with the management of an unknown chemical exposure and the potential consequences if the chemical is a toxic substance. A methodical approach following established protocols can reduce the potential for negative outcomes. Review of the literature found no other report of CS gas exposure from such a personal-protection weapon. PMID:20440402

  8. Investigation of pellet acceleration by an arc heated gas gun

    International Nuclear Information System (INIS)

    Andersen, P.; Andersen, S.A.; Bundgaard, J.; Baekmark, L.; Hansen, B.H.; Jensen, V.O.; Kossek, H.; Michelsen, P.K.; Nordskov, A.; Sass, B.; Soerensen, H.; Weisberg, K.V.

    1987-06-01

    This report describes work on pellet acceleration by means of an arc heated gas gun. The work is a continuation of the work described in RISO-M-2536. The aim of the work is to obtain velocities well above 2 km/s for 3.2 mm diameter deuterium pellets. By means of a cryogenic arc chamber in which the hydrogen propellant is pre-condensed, extruded deutetrium pellets are accelerated up to a maximum velocity of 1.93 km/s. When increasing the energy input to the arc in order to increase the pellet velocity further the heat input to the extrusion/punching pellet loading mechanism was found to be critical: preparation of pellets became difficult and cooling times between shots became inconveniently long. In order to circumvent this problems the concept of a room temperature hydrogen propellant pellet fed arc chamber was proposed. Preliminary results from acceleration of polyurethane pellets with this arc chamber are described as well as the work of developing of feed pellet guns for this chamber. Finally the report describes design consideration for a high pressure propellant pellet fed arc chamber together with preliminary results obtained with a proto-type arc chamber. (author)

  9. Particle transport and gas feed during gun injection

    International Nuclear Information System (INIS)

    Fowler, T K.

    1999-01-01

    It is shown that ion and neutral transport during gun injection tends to equalize the density in the spheromak to that in the open-line current channel. Since a gun operating at or near the ion saturation current requires a minimum density, because of transport these gun requirements also determine a minimum density in the spheromak that increases as the field increases. Hence attaining high fields by gun injection sets lower limits on the density, which in turn limits the temperature of the plasma and increases its ohmic resistance. Estimates of these effects are given using 0-D models calibrated to CTX, as guidance to 2-D UEDGE calculations in progress. For gun power levels in SSPX and the Pulsed Spheromak reactor, we find that buildup persists to the highest field levels of interest

  10. Current distribution measurements inside an electromagnetic plasma gun operated in a gas-puff mode

    OpenAIRE

    Poehlmann, Flavio R.; Cappelli, Mark A.; Rieker, Gregory B.

    2010-01-01

    Measurements are presented of the time-dependent current distribution inside a coaxial electromagnetic plasma gun. The measurements are carried out using an array of six axially distributed dual-Rogowski coils in a balanced circuit configuration. The radial current distributions indicate that operation in the gas-puff mode, i.e., the mode in which the electrode voltage is applied before injection of the gas, results in a stationary ionization front consistent with the presence of a plasma def...

  11. Characterization of a Y-TZP Zirconia material for gas gun experiments

    Science.gov (United States)

    Goff, Michael; Millett, Jeremy; Whiteman, Glenn; Collinson, Mark; Ferguson, James

    2017-06-01

    A number of shots were carried out on the AWE single stage gas gun with Het-V diagnostics to determine the shock Hugoniot of a commercial Y-TZP Zirconia ceramic material (ρ 6.05 g/cc). Zirconia ceramic has a higher density and acoustic impedance than alumina, this allows for higher shock pressures to be achieved in impact velocity limited scenarios where conductive materials are not suitable. For example, when using electromagnetic particle velocity gauge diagnostics. The grade examined here was highly reflective to 1550 nm wavelengths, which negated the need for window materials when taking free surface velocity measurements. The shock Hugoniot was determined to be linear up to 13.4 GPa with the form Us = 5.82 + 2.20Up and the HEL was in the range of 7-9 GPa. Additionally data from lateral gauge shots examining the failure behavior of the material are reported on. ©British Crown Owned Copyright 2017/AWE

  12. A light-gas gun for acceleration of pellets of solid D2

    International Nuclear Information System (INIS)

    Nordskov, A.; Skovgaard, H.; Soerensen, H.; Weisberg, K.V.

    1980-10-01

    A gun has been designed and built to be used for injecting solid D 2 pellets into a small tokamak for pellet-plasma interaction studies. The pellets are formed and accelerated at temperatures close to those of liquid helium. They are propelled with pressurised H 2 -gas; the pressure arises when a quantity of solid H 2 placed in the gun barrel behind the pellet is pulse heated. Pellet velocities up to 240 m/s have been obtained. The directional accuracy is better than 0.2deg and the repetition rate is one firing every five minutes. The pellet volume is 0.6 mm 3 (2 x 10 19 molecules) while the quantity of propeller gas used is around 12 x 10 19 molecules. (author)

  13. A cold cathode of a gas-discharge electron-ion gun

    International Nuclear Information System (INIS)

    1974-01-01

    A cold cathode of a gas-discharge electron-ion gun is constructed in order to continuously replace the eroded material by feeding a wire or a set of coaxial cylinders in the spot where the ions hit the cathode. In this way, the form of the cathode and the electric-field configuration is preserved which guarantees the conservation of a sharp narrow electron beam profile

  14. Review of gas gun technology with emphasis on fusion fueling applications

    International Nuclear Information System (INIS)

    Flagg, R.F.

    1978-01-01

    A review is made of current light gas gun and related hyper-velocity launcher technology with emphasis on physical and technological limits, advantages, and disadvantages as they apply to injection requirements for refueling Tokamak type nuclear fusion reactors. It is shown that the mass and velocity requirements for refueling are well within the capabilities of the state of the art and can be produced by several of the different types of gun/launching devices. The practical problems of adapting this performance capability to the refueling task are addressed and some possible configurations are given including both single pellet and multiple pellet injection. A short bibliography is given for those who wish additional detailed information

  15. Fabrication and characterization of graded impedance impactors for gas gun experiments from tape cast metal powders

    International Nuclear Information System (INIS)

    Martin, L. Peter; Orlikowski, Daniel; Nguyen, Jeffrey H.

    2006-01-01

    Fabrication of compositionally graded structures for use as light-gas gun impactors has been demonstrated using a tape casting technique. Mixtures of metal powders in the Mg-Cu system were cast into a series of tapes with uniform compositions ranging from 100% Mg to 100% Cu. The individual compositions were fabricated into monolithic pellets for characterization by laminating multiple layers together, thermally removing the organics, and hot-pressing to near-full density. The pellets were characterized by optical and scanning electron microscopy, X-ray diffraction, and measurement of density and sound wave velocity. The density and acoustic impedance were observed to vary monotonically (and nearly linearly) with composition. Graded structures were fabricated by stacking layers of different compositions in a sequence calculated to yield a desired acoustic impedance profile. The measured physical properties of the graded structures compare favorably with those predicted from the monolithic pellet characteristics. Fabrication of graded impactors by this technique is of significant interest for providing improved control of the pressure profile and impactor planarity in gas gun experiments

  16. Shock Initiation Behavior of PBXN-9 Determined by Gas Gun Experiments

    Science.gov (United States)

    Sanchez, N. J.; Gustavsen, R. L.; Hooks, D. E.

    2009-12-01

    The shock to detonation transition was evaluated in the HMX based explosive PBXN-9 by a series of light-gas gun experiments. PBXN-9 consists of 92 wt% HMX, 2wt% Hycar 4054 & 6 wt&percent; dioctyl adipate with a density of 1.75 g/cm3 and 0.8&% voids. The experiments were designed to understand the specifics of wave evolution and the run distance to detonation as a function of input shock pressure. These experiments were conducted on gas guns in order to vary the input shock pressure accurately. The primary diagnostics were embedded magnetic gauges, which are based on Faraday's law of induction, and Photon Doppler Velocimetry (PDV). The run distance to detonation vs. shock pressure, or "Pop plot," was redefined as log(X) = 2.14-1.82 log (P), which is substantially different than previous data. The Hugoniot was refined as Us = 2.32+2.211 Up. This data will be useful for the development of predictive models for the safety and performance of PBXN-9 along with providing increased understanding of HMX based explosives in varying formulations.

  17. Current distribution measurements inside an electromagnetic plasma gun operated in a gas-puff mode.

    Science.gov (United States)

    Poehlmann, Flavio R; Cappelli, Mark A; Rieker, Gregory B

    2010-12-01

    Measurements are presented of the time-dependent current distribution inside a coaxial electromagnetic plasma gun. The measurements are carried out using an array of six axially distributed dual-Rogowski coils in a balanced circuit configuration. The radial current distributions indicate that operation in the gas-puff mode, i.e., the mode in which the electrode voltage is applied before injection of the gas, results in a stationary ionization front consistent with the presence of a plasma deflagration. The effects of varying the bank capacitance, transmission line inductance, and applied electrode voltage were studied over the range from 14 to 112 μF, 50 to 200 nH, and 1 to 3 kV, respectively.

  18. Development of intense pulsed heavy ion beam diode using gas puff plasma gun as ion source

    International Nuclear Information System (INIS)

    Ito, H.; Higashiyama, M.; Takata, S.; Kitamura, I.; Masugata, K.

    2006-01-01

    A magnetically insulated ion diode with an active ion source of a gas puff plasma gun has been developed in order to generate a high-intensity pulsed heavy ion beam for the implantation process of semiconductors and the surface modification of materials. The nitrogen plasma produced by the plasma gun is injected into the acceleration gap of the diode with the external magnetic field system. The ion diode is operated at diode voltage approx. =200 kV, diode current approx. =2 kA and pulse duration approx. =150 ns. A new acceleration gap configuration for focusing ion beam has been designed in order to enhance the ion current density. The experimental results show that the ion current density is enhanced by a factor of 2 and the ion beam has the ion current density of 27 A/cm 2 . In addition, the coaxial type Marx generator with voltage 200 kV and current 15 kA has been developed and installed in the focus type ion diode. The ion beam of ion current density approx. =54 A/cm 2 is obtained. To produce metallic ion beams, an ion source by aluminum wire discharge has been developed and the aluminum plasma of ion current density ∼70 A/cm 2 is measured. (author)

  19. RESIDUAL RISK ASSESSMENT: GAS DISTRIBUTION STAGE ...

    Science.gov (United States)

    This document describes the residual risk assessment for the Gas Distribution Stage 1 souce category. For stationary sources, section 112 (f) of the Clean Air Act requires EPA to assess risks to human health and the environment following implementation of technology-based control standards. If these technology-based control standards do not provide an ample margin of safety, then EPA is required to promulgate addtional standards. This document describes the methodology and results of the residual risk assessment performed for the Gas Distribution Stage 1 source category. The results of this analyiss will assist EPA in determining whether a residual risk rule for this source category is appropriate.

  20. Development of high velocity gas gun with a new trigger system-numerical analysis

    Science.gov (United States)

    Husin, Z.; Homma, H.

    2018-02-01

    In development of high performance armor vests, we need to carry out well controlled experiments using bullet speed of more than 900 m/sec. After reviewing trigger systems used for high velocity gas guns, this research intends to develop a new trigger system, which can realize precise and reproducible impact tests at impact velocity of more than 900 m/sec. A new trigger system developed here is called a projectile trap. A projectile trap is placed between a reservoir and a barrel. A projectile trap has two functions of a sealing disk and triggering. Polyamidimide is selected for the trap material and dimensions of the projectile trap are determined by numerical analysis for several levels of launching pressure to change the projectile velocity. Numerical analysis results show that projectile trap designed here can operate reasonably and stresses caused during launching operation are less than material strength. It means a projectile trap can be reused for the next shooting.

  1. Magnetic Ignition of Pulsed Gas Discharges in Air of Low Pressure in a Coaxial Plasma Gun

    Science.gov (United States)

    Thom, Karlheinz; Norwood, Joseph, Jr.

    1961-01-01

    The effect of an axial magnetic field on the breakdown voltage of a coaxial system of electrodes has been investigated by earlier workers. For low values of gas pressure times electrode spacing, the breakdown voltage is decreased by the application of the magnetic field. The electron cyclotron radius now assumes the role held by the mean free path in nonmagnetic discharges and the breakdown voltage becomes a function of the magnetic flux density. In this paper the dependence of the formative time lag as a function of the magnetic flux density is established and the feasibility of using a magnetic field for igniting high-voltage, high-current discharges is shown through theory and experiment. With a 36 microfarad capacitor bank charged to 48,000 volts, a peak current of 1.3 x 10( exp 6) amperes in a coaxial type of plasma gun was achieved with a current rise time of only 2 microseconds.

  2. Study of the electrical signals observed during the initial stage in a coaxial gun

    International Nuclear Information System (INIS)

    Moreno, C.; Vieytes, R.

    1995-01-01

    In this work high frequency oscillations further experimental data, along with its theoretical modeling will be given for initial phase in a coaxial gun constructed to be used in technological applications of plasma. Particular attention was devoted to find any dependence between the measured frequencies and the operating pressure and voltage. 1 ref., 1 fig., 1 tab

  3. Studying multiply shocked states in HMX and TATB based explosives with a gas gun ring up geometry

    Science.gov (United States)

    Ferguson, James; Finnegan, Simon; Millett, Jeremy; Goff, Michael

    2017-06-01

    A series of ring up shots investigating partially reacted and multiply shocked states in both HMX and TATB based explosives are reported on. Results of experiments using PCTFE and LiF in place of the explosives are also described. The experiments were performed using 50 mm diameter bore and 70 mm diameter bore single stage gas guns. By locating the target between a high impedance copper flyer and sapphire window, shocks of increasing magnitude are reflected into the target at each interface. The particle velocity at the target-window interface was measured using multiple points of HetV reflected from an 800 nm layer of gold sputtered onto the sapphire. The stress state at the target-flyer interface were observed using manganin gauges. A range of different input pressures were investigated, these were picked to either allow a comparison to double shock and particle velocity work, or to provide the maximum number of rings within the one dimensional time. For the inert shots input pressures matched the explosive shots.

  4. Advanced diagnostics for impact-flash spectroscopy on light-gas guns.

    Energy Technology Data Exchange (ETDEWEB)

    Breiland, William George; Reinhart, William Dodd; Miller, Paul Albert; Brown, Justin L.; Thornhill, Tom Finley, III (,; ); Mangan, Michael A.; Shaner, Eric Arthur; Chhabildas, Lalit Chandra; Grine, Albert D.; Wanke, Michael Clement; Alexander, C. Scott

    2007-03-01

    This study is best characterized as new technology development for implementing new sensors to investigate the optical characteristics of a rapidly expanding debris cloud resulting from hypervelocity impact regimes of 7 to 11 km/s. Our gas guns constitute a unique test bed that match operational conditions relevant to hypervelocity impact encountered in space engagements. We have demonstrated the use of (1) terahertz sensors, (2) silicon diodes for visible regimes, (3) germanium and InGaAs sensors for the near infrared regimes, and (4) the Sandia lightning detectors which are similar to the silicon diodes described in 2. The combination and complementary use of all these techniques has the strong potential of ''thermally'' characterizing the time dependent behavior of the radiating debris cloud. Complementary spectroscopic measurements provide temperature estimates of the impact generated debris by fitting its spectrum to a blackbody radiation function. This debris is time-dependent as its transport/expansion behavior is changing with time. The rapid expansion behavior of the debris cools the cloud rapidly, changing its thermal/temperature characteristics with time. A variety of sensors that span over a wide spectrum, varying from visible regime to THz frequencies, now gives us the potential to cover the impact over a broader temporal regime starting from high pressures (Mbar) high-temperatures (eV) to low pressures (mbar) low temperatures (less than room temperature) as the debris expands and cools.

  5. Evaluation of the LLNL Spectrometer for Possible use with the NSTec Optical Streak Camera as a Light Gas Gun Diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    O' Connor, J., Cradick, J.

    2012-09-27

    In fiscal year 2012, it was desired to combine a visible spectrometer with a streak camera to form a diagnostic system for recording time-resolved spectra generated in light gas gun experiments. Acquiring a new spectrometer was an option, but it was possible to borrow an existing unit for a period of months, which would be sufficient to evaluate both “off-line” and in-gas gun shots. If it proved adequate for this application, it could be duplicated (with possible modifications); if not, such testing would help determine needed specifications for another model. This report describes the evaluation of the spectrometer (separately and combined with the NSTec LO streak camera) for this purpose. Spectral and temporal resolutions were of primary interest. The first was measured with a monochromatic laser input. The second was ascertained by the combination of the spectrometer’s spatial resolution in the time-dispersive direction and the streak camera’s intrinsic temporal resolution. System responsivity was also important, and this was investigated by measuring the response of the spectrometer/camera system to black body input—the gas gun experiments are expected to be similar to a 3000K black body—as well as measuring the throughput of the spectrometer separately over a range of visible light provided by a monochromator. The flat field (in wavelength) was also measured and the final part of the evaluation was actual fielding on two gas gun shots. No firm specifications for spectral or temporal resolution were defined precisely, but these were desired to be in the 1–2 nm and 1–2 ns ranges, respectively, if possible. As seen below, these values were met or nearly met, depending on wavelength. Other performance parameters were also not given (threshold requirements) but the evaluations performed with laser, black body, and successful gas gun shots taken in aggregate indicate that the spectrometer is adequate for this purpose. Even still, some (relatively

  6. Results of the AFWL deflagration gun experiments

    International Nuclear Information System (INIS)

    Hackett, K.E.; Baker, W.L.; Beason, J.D.

    1987-01-01

    The snowplow and deflagration modes of coaxial plasma gun operation have been experimentally investigated and computationally simulated at the Air Force Weapons Laboratory. The snowplow mode occurs when the gun is prefilled to a uniform gas density. The initial breakdown forms near the insulator at the gun breech. It heats the gas and creates a shock wave that travels down the gun, ionizing gas and producing a thin current sheath that travels just behind the shock front. The shock front piles up the gas in front of itself as it moves down the gun - hence the name ''snowplow''. Deflagration occurs when gas is injected into an evacuated gun so that the initial breakdown forms as the gas fills the gun. The ionized gas is accelerated into the vacuum region carrying current and magnetic field with it. A quasi-stationary diffuse discharge develops. Gas still entering the gun is processed through the deflagrating discharge and accelerated out the gun muzzle

  7. Gun Play

    Science.gov (United States)

    Mechling, Jay

    2008-01-01

    Biology and the particular gun culture of the United States come together to explain the persistent and powerful attraction of American boys to both real guns and toy guns. The 1990s saw adults begin to conflate "the gun problem" with "the boy problem," sparking attempts (largely failed) to banish toy guns from homes and…

  8. Understanding the Effect of Gas Dynamics in Plasma Gun Performance for Simulating Fusion Wall Response to Disruption Events

    Science.gov (United States)

    Riedel, Will; Underwood, Thomas; Righetti, Fabio; Cappelli, Mark

    2017-10-01

    In this work, the suitability of a pulsed coaxial plasma accelerator to simulate the interaction of edge-localized modes with plasma first wall materials is investigated. Experimental measurements derived from a suite of diagnostics are presented that focus on both the properties of the plasma flow and the manner in which such jets couple with material interfaces. Specific emphasis is placed on quantifying the variation in these properties using tungsten tokens exposed to the plasma plume as the gun volume is progressively filled with more neutral gas. These results are mapped to the operational dynamics of the gun via a time-resolved Schlieren cinematic visualization of the density gradient within the flow. Resulting videos indicate the existence of two distinct modes with vastly different characteristic timescales, spatial evolution, and plasma properties. Time resolved quantification of the associated plasma heat flux for both modes, including a range spanning 150 MW m-2 - 10 GW m-2, is presented using both a fast thermocouple gauge and an IR camera. Both diagnostics in conjunction with a heat transfer model provide an accurate description of the energy transfer dynamics and operational characteristics of plasma guns. This work is supported by the U.S. Department of Energy Stewardship Science Academic Program.

  9. ION GUN

    Science.gov (United States)

    Dandl, R.A.

    1961-10-24

    An ion gun is described for the production of an electrically neutral ionized plasma. The ion gun comprises an anode and a cathode mounted in concentric relationship with a narrow annulus between. The facing surfaces of the rear portions of the anode and cathode are recessed to form an annular manifold. Positioned within this manifold is an annular intermediate electrode aligned with the an nulus between the anode and cathode. Gas is fed to the manifold and an arc discharge is established between the anode and cathode. The gas is then withdrawn from the manifold through the annulus between the anode and cathode by a pressure differential. The gas is then ionized by the arc discharge across the annulus. The ionized gas is withdrawn from the annulus by the combined effects of the pressure differential and a collimating magnetic field. In a 3000 gauss magnetic field, an arc voltage of 1800 volts, and an arc current of 0.2 amp, a plasma of about 3 x 10/sup 11/ particles/cc is obtained. (AEC)

  10. Gun Safety

    Science.gov (United States)

    Many U.S. households have guns, but they can cause harm if not handled properly. Here are some things you can do to keep yourself and ... safe: Teach children that they shouldn't touch guns and that if they see a gun, to ...

  11. Gas gun experiments and numerical simulations on the HMX-based explosive PBX 9501 in the overdriven 30 to 120 GPa pressure regime

    Science.gov (United States)

    Pittman, E. R.; Gustavsen, R. L.; Hagelberg, C. R.; Schmidt, J. H.

    2017-06-01

    The focus of this set of experiments is the development of data on the Hugoniot for the overdriven products equation of state (EOS) of PBX 9501 (95 weight % HMX, 5 weight % plastic binder) and to extend data from which current computational EOS models draw. This series of shots was conducted using the two-stage gas-guns at Los Alamos and aimed to gather data in the 30 to 120 GPa pressure regime. Experiments were simulated using FLAG, a Langrangian multiphysics code, using a one-dimensional setup which employs the Wescott Stewart Davis (WSD) reactive burn model. Prior to this study, data did not extend above 90 GPa, so the new data allowed the model to be re-evaluated. A comparison of the simulations with the experimental data shows that the model fits well below 80 GPa. However, the model did not fall within the error bars of the data for higher pressures. This is an indication that the PBX 9501 overdriven EOS products model could be modified to better match the data.

  12. Gun Safety (For Kids)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Gun Safety KidsHealth / For Kids / Gun Safety What's in ... from guns outside the home. If You Have Guns in Your Home If your parents keep guns ...

  13. Sanoli Gun

    Indian Academy of Sciences (India)

    Home; Journals; Proceedings – Mathematical Sciences. Sanoli Gun. Articles written in Proceedings – Mathematical Sciences. Volume 119 Issue 3 June 2009 pp 275-281. Remarks on some Zero-Sum Theorems · S D Adhikari Sanoli Gun Purusottam Rath · More Details Abstract Fulltext PDF. In the present paper, we give a ...

  14. Gun Violence and Gun Control

    OpenAIRE

    Greenberg, Mark; Litman, Harry

    2009-01-01

    This short essay was commissioned by the London Review of Books, but in the end we decided not to publish it, in part because we felt that there were empirical issues that we were not in a position to assess. A longer working paper that develops the argument further and contains supporting material is posted on SSRN under the title "Rethinking Gun Violence." We welcome comments on either paper. The essay takes Joyce Malcolm's Guns and Violence and Jim Jacobs's Can Gun Control Work? as jump...

  15. Gun Control, Gun Ownership, and Suicide Prevention.

    Science.gov (United States)

    Lester, David

    1988-01-01

    Explored relationship between the extent of gun ownership and the strictness of gun control laws to suicide and homicide rates in the nine major geographic regions of the United States. Found gun ownership, rather than the strictness of gun control laws, was the strongest correlate of the rates of suicide and homicide by guns. (Author)

  16. A Thomson-type mass and energy spectrometer for characterizing ion energy distributions in a coaxial plasma gun operating in a gas-puff mode

    OpenAIRE

    Rieker, G. B.; Poehlmann, F. R.; Cappelli, M. A.

    2013-01-01

    Measurements of ion energy distribution are performed in the accelerated plasma of a coaxial electromagnetic plasma gun operating in a gas-puff mode at relatively low discharge energy (900 J) and discharge potential (4 kV). The measurements are made using a Thomson-type mass and energy spectrometer with a gated microchannel plate and phosphor screen as the ion sensor. The parabolic ion trajectories are captured from the sensor screen with an intensified charge-coupled detector camera. The spe...

  17. Combustion of coal gas fuels in a staged combustor

    Science.gov (United States)

    Rosfjord, T. J.; Mcvey, J. B.; Sederquist, R. A.; Schultz, D. F.

    1982-01-01

    Gaseous fuels produced from coal resources generally have heating values much lower than natural gas; the low heating value could result in unstable or inefficient combustion. Coal gas fuels may contain ammonia which if oxidized in an uncontrolled manner could result in unacceptable nitrogen oxide exhaust emission levels. Previous investigations indicate that staged, rich-lean combustion represents a desirable approach to achieve stable, efficient, low nitrogen oxide emission operation for coal-derived liquid fuels contaning up to 0.8-wt pct nitrogen. An experimental program was conducted to determine whether this fuel tolerance can be extended to include coal-derived gaseous fuels. The results of tests with three nitrogen-free fuels having heating values of 100, 250, and 350 Btu/scf and a 250 Btu/scf heating value doped to contain 0.7 pct ammonia are presented.

  18. Spectrometer gun

    Science.gov (United States)

    Waechter, David A.; Wolf, Michael A.; Umbarger, C. John

    1985-01-01

    A hand-holdable, battery-operated, microprocessor-based spectrometer gun includes a low-power matrix display and sufficient memory to permit both real-time observation and extended analysis of detected radiation pulses. Universality of the incorporated signal processing circuitry permits operation with various detectors having differing pulse detection and sensitivity parameters.

  19. Experimental studies of coaxial plasma gun current

    International Nuclear Information System (INIS)

    Price, D.W.

    1988-01-01

    In this investigation of a coaxial plasma gun, plasma sheath currents and related behavior are examined. Plasma behavior in the gun affects gun characteristics. Plasma gun applications are determined by the plasma behavior. The AFWL PUFF capacitor bank (72 μF, 29 nH, 120 kV) drives the plasma gun using a deuterium fill gas. The gas breakdown site is isolated from the dielectric/vacuum interface in the AFWL system. Two gas values deliver gas in the system. The first delivers gas from the gun breech and the second optional valve delivers gas to the gun muzzle. Currents and voltages are measured by Rogowski coils, B probes and capacitive voltage probes. A O-D slug model is used to predict the current, inductance, gun voltage and plasma sheath velocity. The slug model assumes the sheath transits the gun with all mass in the sheath. In the snowplow mode, the plasma sheath is thin with a sharp current rise and drop. Our system operated in a transition mode between the snowplow and deflagration modes with early snowplow behavior and late deflagration behavior. Neutrons are produced in a plasma pinch at the gun muzzle, indicating snowplow behavior. The slug theory models overall gun behavior to experimental accuracy. Experimental results are compared to four theories for plasma sheath velocities: the Alfven collisionally limited model, the Rosenbluth model, the Fishbine saturated model and a single particle drift model. Experimental velocities vary from 10 5 to 10 6 m/s. Only the single particle drift and the slug model calculations are of the right magnitude (8 x 10 5 m/s). The Fishbine and the Rosenbluth models predict slower velocities (2 x 10 5 m/s). The Alfven model is not applicable to this system

  20. Water gun vs air gun: A comparison

    Science.gov (United States)

    Hutchinson, D.R.; Detrick, R. S.

    1984-01-01

    The water gun is a relatively new marine seismic sound source that produces an acoustic signal by an implosive rather than explosive mechanism. A comparison of the source characteristics of two different-sized water guns with those of conventional air guns shows the the water gun signature is cleaner and much shorter than that of a comparable-sized air gun: about 60-100 milliseconds (ms) for an 80-in3. (1.31-liter (I)) water gun compared with several hundred ms for an 80-in3. (1.31-1) air gun. The source spectra of water guns are richer in high frequencies (>200 Hz) than are those of air guns, but they also have less energy than those of air guns at low frequencies. A comparison between water gun and air gun reflection profiles in both shallow (Long Island Sound)-and deep (western Bermuda Rise)-water settings suggests that the water gun offers a good compromise between very high resolution, limited penetration systems (e.g. 3.5-kHz profilers and sparkers) and the large volume air guns and tuned air gun arrays generally used where significant penetration is required. ?? 1984 D. Reidel Publishing Company.

  1. Plasma-gun fueling for tokamak reactors

    International Nuclear Information System (INIS)

    Ehst, D.A.

    1980-11-01

    In light of the uncertain extrapolation of gas puffing for reactor fueling and certain limitations to pellet injection, the snowplow plasma gun has been studied as a fueling device. Based on current understanding of gun and plasma behavior a design is proposed, and its performance is predicted in a tokamak reactor environment

  2. ELECTRON GUN

    Science.gov (United States)

    Christofilos, N.C.; Ehlers, K.W.

    1960-04-01

    A pulsed electron gun capable of delivering pulses at voltages of the order of 1 mv and currents of the order of 100 amperes is described. The principal novelty resides in a transformer construction which is disposed in the same vacuum housing as the electron source and accelerating electrode structure of the gun to supply the accelerating potential thereto. The transformer is provided by a plurality of magnetic cores disposed in circumferentially spaced relation and having a plurality of primary windings each inductively coupled to a different one of the cores, and a helical secondary winding which is disposed coaxially of the cores and passes therethrough in circumferential succession. Additional novelty resides in the disposition of the electron source cathode filament input leads interiorly of the transformer secondary winding which is hollow, as well as in the employment of a half-wave filament supply which is synchronously operated with the transformer supply such that the transformer is pulsed during the zero current portions of the half-wave cycle.

  3. Gun ownership and social gun culture.

    Science.gov (United States)

    Kalesan, Bindu; Villarreal, Marcos D; Keyes, Katherine M; Galea, Sandro

    2016-06-01

    We assessed gun ownership rates in 2013 across the USA and the association between exposure to a social gun culture and gun ownership. We used data from a nationally representative sample of 4000 US adults, from 50 states and District of Columbia, aged >18 years to assess gun ownership and social gun culture performed in October 2013. State-level firearm policy information was obtained from the Brady Law Center and Injury Prevention and Control Center. One-third of Americans reported owning a gun, ranging from 5.2% in Delaware to 61.7% in Alaska. Gun ownership was 2.25-times greater among those reporting social gun culture (PR=2.25, 95% CI 2.02 to 2.52) than those who did not. In conclusion, we found strong association between social gun culture and gun ownership. Gun cultures may need to be considered for public health strategies that aim to change gun ownership in the USA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. Encyclopedia of Gun Control and Gun Rights.

    Science.gov (United States)

    Utter, Glenn H.

    This reference volume provides information on gun control and gun rights, including resources on the debate surrounding the Second Amendment and individuals and organizations focused on gun issues, along with statutes, court cases, events, and publications surrounding this current topic. Highlighted are the important organizations and their…

  5. Sonic Rarefaction Wave Low Recoil Gun

    National Research Council Canada - National Science Library

    Kathe, E

    2002-01-01

    .... The sonic RArefaction waVE low recoil guN (RAVEN) is a novel invention to dramatically reduce the gas momentum contribution to recoil with absolutely no reduction in me ballistic efficiency of launch...

  6. Gun ownership and social gun culture

    OpenAIRE

    Kalesan, Bindu; Villarreal, Marcos D; Keyes, Katherine M; Galea, Sandro

    2015-01-01

    We assessed gun ownership rates in 2013 across the USA and the association between exposure to a social gun culture and gun ownership. We used data from a nationally representative sample of 4000 US adults, from 50 states and District of Columbia, aged >18 years to assess gun ownership and social gun culture performed in October 2013. State-level firearm policy information was obtained from the Brady Law Center and Injury Prevention and Control Center. One-third of Americans reported owning a...

  7. Keeping Naval Guns Ready

    Science.gov (United States)

    2016-03-01

    and stay aboard until the gun is up. Whatever the case, the goal is to get the gun up fast. Guns With Fast “Pit Crews” Winning in stock- car racing...after firing in a corrosive maritime environment. The original maintenance philosophy was to remove a gun from the ship and send it back to the

  8. The Gun Dispute.

    Science.gov (United States)

    Spitzer, Robert J.

    1999-01-01

    Explores the debate over gun ownership and gun control in the United States, focusing on the historic place of guns in U.S. society. The current national mood is more receptive than ever to restricting and regulating adolescent access to guns in light of recent school shootings. (SLD)

  9. Gun Sales. Firearm Facts.

    Science.gov (United States)

    Duker, Laurie, Ed.

    Minimal federal regulations on firearm sales have facilitated the proliferation of guns, gun owners, and gun dealers in the United States. This fact sheet offers data on the growing number of firearm dealers, the relative ease of obtaining and keeping a license to sell guns from the Federal Bureau of Alcohol, Tobacco, and Firearms, the lack of…

  10. A Thomson-type mass and energy spectrometer for characterizing ion energy distributions in a coaxial plasma gun operating in a gas-puff mode

    Science.gov (United States)

    Rieker, G. B.; Poehlmann, F. R.; Cappelli, M. A.

    2013-07-01

    Measurements of ion energy distribution are performed in the accelerated plasma of a coaxial electromagnetic plasma gun operating in a gas-puff mode at relatively low discharge energy (900 J) and discharge potential (4 kV). The measurements are made using a Thomson-type mass and energy spectrometer with a gated microchannel plate and phosphor screen as the ion sensor. The parabolic ion trajectories are captured from the sensor screen with an intensified charge-coupled detector camera. The spectrometer was designed and calibrated using the Geant4 toolkit, accounting for the effects on the ion trajectories of spatial non-uniformities in the spectrometer magnetic and electric fields. Results for hydrogen gas puffs indicate the existence of a class of accelerated protons with energies well above the coaxial discharge potential (up to 24 keV). The Thomson analyzer confirms the presence of impurities of copper and iron, also of relatively high energies, which are likely erosion or sputter products from plasma-electrode interactions.

  11. A Thomson-type mass and energy spectrometer for characterizing ion energy distributions in a coaxial plasma gun operating in a gas-puff mode

    Energy Technology Data Exchange (ETDEWEB)

    Rieker, G. B.; Poehlmann, F. R.; Cappelli, M. A. [High Temperature Gasdynamics Laboratory, Stanford University, Stanford, California 94305 (United States)

    2013-07-15

    Measurements of ion energy distribution are performed in the accelerated plasma of a coaxial electromagnetic plasma gun operating in a gas-puff mode at relatively low discharge energy (900 J) and discharge potential (4 kV). The measurements are made using a Thomson-type mass and energy spectrometer with a gated microchannel plate and phosphor screen as the ion sensor. The parabolic ion trajectories are captured from the sensor screen with an intensified charge-coupled detector camera. The spectrometer was designed and calibrated using the Geant4 toolkit, accounting for the effects on the ion trajectories of spatial non-uniformities in the spectrometer magnetic and electric fields. Results for hydrogen gas puffs indicate the existence of a class of accelerated protons with energies well above the coaxial discharge potential (up to 24 keV). The Thomson analyzer confirms the presence of impurities of copper and iron, also of relatively high energies, which are likely erosion or sputter products from plasma-electrode interactions.

  12. More Guns, More Crime

    OpenAIRE

    Mark Duggan

    2000-01-01

    This paper examines the relationship between gun ownership and crime. Previous research has suffered from a lack of reliable data on gun ownership. I exploit a unique data set to reliably estimate annual gun ownership rates at both the state and the county level during the past two decades. My findings demonstrate that changes in gun ownership are significantly positively related to changes in the homicide rate, with this relationship driven entirely by the impact of gun ownership on murders ...

  13. New Electron Gun System for BEPCII

    CERN Document Server

    Liu, Bo; Long Chi, Yun; Zhang, Chuang

    2005-01-01

    The new electron gun system for BEPCII has been put into operation since Nov. 2004. The article describes the design, experiment and operation of this new system. The design current of the gun is 10 A for the pulse lengths of 1 ns, 2.5 ns and 1 μs with repetition rate of 50 Hz. The gun is operated with a pulsed high voltage power supply which can provide up to 200 kV high voltage. Computer simulations have been carried out in the design stage, including simulation of the gun geometry and beam transportation. Some important relation curves are obtained during the experiment. Two-bunch operation is available and some elementary tests have been performed. New scheme of the gun control system based on EPICS is also presented. The real operation shows that the design and manufacturing is basically successful.

  14. Investigation of pellet acceleration by an arc heated gas gun. An interim report of the investigations carried out to 31 August 1985

    International Nuclear Information System (INIS)

    Andersen, S.A.; Bundgaard, J.; Jensen, V.O.; Nordskov, A.; Sass, B.; Soerensen, H.; Weisberg, K.V.

    1985-12-01

    Deep penetration of pellets into the JET plasma may prove to be a useful tool for density and profile control. In JET deep penetration will require pellet velocities and sizes above those obtained so far. An experimental setup designed for a study of acceleration of 3 mm diameter pellets by an arc heated gas gun is described. The aim of the work is to obtain pellet velocities well above 2 km/s. To obtain this aim will require a much more powerful power unit than the one that was available for the present work. Only a few results, obtained mostly during testing of the various parts of the setup, are presented. Although the obtained velocities are low (∝1500 m/s) the results are encouraging because they demonstrate that pellets can stand a high acceleration pressure without disintegrating. With a suitable power supply which can maintain this high acceleration pressure as the pellet moves all the way through the barrel, velocities above 2 km/s would certainly be expected. (orig.)

  15. Early stages in the history of gas chromatography.

    Science.gov (United States)

    Kolomnikov, Ivan G; Efremov, Alexander M; Tikhomirova, Tatyana I; Sorokina, Nadezhda M; Zolotov, Yury A

    2018-02-16

    The creation of gas chromatography is traditionally associated with the names of Nobel Prize winner Archer Martin and his colleagues Richard Synge and Anthony James. However, sometimes references to their predecessors can be found. An investigation conducted by the authors of this article not only confirmed the reliability of these references; but in fact led to the conclusion that by 1952, which is commonly believed to be the year when gas chromatography was born, many research papers had already been devoted to this method, mainly, in its gas-solid version. These papers are considered in this article. Copyright © 2018. Published by Elsevier B.V.

  16. Two-stage coal liquefaction without gas-phase hydrogen

    Science.gov (United States)

    Stephens, H.P.

    1986-06-05

    A process is provided for the production of a hydrogen-donor solvent useful in the liquefaction of coal, wherein the water-gas shift reaction is used to produce hydrogen while simultaneously hydrogenating a donor solvent. A process for the liquefaction of coal using said solvent is also provided. The process enables avoiding the use of a separate water-gas shift reactor as well as high pressure equipment for liquefaction. 3 tabs.

  17. Guns and Violence. Current Controversies.

    Science.gov (United States)

    Kim, Henny H., Ed.

    This book focuses on gun violence and gun control, presenting both sides of arguments about firearms ownership and gun control. Each of five chapters poses a question about gun control and provides answers for both sides of the question. The following essays are included: (1) "Gun Violence Is Becoming an Epidemic" (Bob Herbert); (2) "Gun Violence…

  18. ORELA electron guns

    International Nuclear Information System (INIS)

    Christian, O.W.; Lewis, T.A.

    1981-09-01

    The most recent information concerning the production and performance of ORELA electron guns is presented. Included are descriptions of procedures for gun fabrication, cathode conditioning and high voltage processing. Highlights of the performance characteristics are also included

  19. Alpha Fuels Environmental Test Facility impact gun

    International Nuclear Information System (INIS)

    Anderson, C.G.

    1978-01-01

    The Alpha Fuels Environmental Test Facility (AFETF) impact gun is a unique tool for impact testing 238 PuO 2 -fueled heat sources of up to 178-mm dia at velocities to 300 m/s. An environmentally-sealed vacuum chamber at the muzzle of the gun allows preheating of the projectile to 1,000 0 C. Immediately prior to impact, the heat source projectile is completely sealed in a vacuum-tight catching container to prevent escape of its radioactive contents should rupture occur. The impact velocity delivered by this gas-powered gun can be regulated to within +-2%

  20. Is Gun Violence Contagious?

    OpenAIRE

    Loeffler, Charles; Flaxman, Seth

    2016-01-01

    Existing theories of gun violence predict stable spatial concentrations and contagious diffusion of gun violence into surrounding areas. Recent empirical studies have reported confirmatory evidence of such spatiotemporal diffusion of gun violence. However, existing tests cannot readily distinguish spatiotemporal clustering from spatiotemporal diffusion. This leaves as an open question whether gun violence actually is contagious or merely clusters in space and time. Compounding this problem, g...

  1. Gun Safety (For Parents)

    Science.gov (United States)

    ... or adult feels suicidal and there is a gun readily available. A family argument gets out of control. A family member or friend is mistaken for an intruder. Remember: The best way to prevent gun injuries is to never keep guns at home ...

  2. Design of e-gun for large KrF amplifiers

    International Nuclear Information System (INIS)

    Reilly, D.A.; Von Rosenberg, C.W.

    1985-01-01

    The design of very large single-aperture laser amplifier for an angular multiplexed laser fusion system requires advances in excimer laser e-gun technology beyond existing designs. Scaling considerations dictate the use of multiple e-guns to pump a single laser; in the present case the authors will discuss the scaling and design features of one of the ten e-guns being developed to pump the Los Alamos Polaris Power Amplifier Module. Multiple e-guns minimize the diode self-magnetic field, lowering the size of the imposed guide magnetic field, and reducing the diode impendance collapse. Multiple guns also result in lowered current rise times, reduce the development cost of the technology at the prototype stage, and, of course, limit the cost due to operation failures in the e-gun. The present design utilizes the expanding electron flow diode to provide uniform electron flow into the gas from a high-current density cold cathode (approx. =50 A/cm 2 ). Laminated iron and an imposed dipole field are utilized for B-field shaping. The applied B field lines trace from the anode, terminate on the cathode, and are then conducted through the shank to beyond the bushing. This feature not only provides for fully expanded electron flow from cathode to anode, but it also allows for self-magnetic field insulation of the shank and bushing, thus minimizing voltage standoff distances, inductance, and rise time. A single large aspect ratio racetrack-shaped bushing on each e-gun is provided with robust grading to limit field concentration at the ends

  3. Two-step two-stage fission gas release model

    International Nuclear Information System (INIS)

    Kim, Yong-soo; Lee, Chan-bock

    2006-01-01

    Based on the recent theoretical model, two-step two-stage model is developed which incorporates two stage diffusion processes, grain lattice and grain boundary diffusion, coupled with the two step burn-up factor in the low and high burn-up regime. FRAPCON-3 code and its in-pile data sets have been used for the benchmarking and validation of this model. Results reveals that its prediction is in better agreement with the experimental measurements than that by any model contained in the FRAPCON-3 code such as ANS 5.4, modified ANS5.4, and Forsberg-Massih model over whole burn-up range up to 70,000 MWd/MTU. (author)

  4. Axial liquid mixing in a gas-liquid Multi-Stage Agitated Contactor (MAC)

    NARCIS (Netherlands)

    Breman, B.B; Beenackers, A.A C M; Bouma, M.J; VanderWerf, M.H.

    Data on interstage liquid mixing are reported for a gas-liquid Multi-stage Agitated Contactor (MAC). A dynamic method using heat as a tracer was applied for water, n-octane and monoethylene glycol as liquids both with and without the presence of a dispersed gas phase (air). In all cases, the axial

  5. Development of repair mechanism of FSX-414 based 1st stage nozzle of gas turbine

    Science.gov (United States)

    Rahman, Md. Tawfiqur

    2017-06-01

    This paper describes the failure mechanism and repair technology of 1st stage nozzle or vane of industrial gas turbine which is made of cobalt based super alloy FSX-414. 1st stage nozzles or vanes are important stationery components of gas turbine based power plant. Those are the parts of hot gas path components of gas turbine and their manufacturing process is casting. At present, it is widely accepted that gas turbine based combined cycle power plant is the most efficient and cost effective solution to generate electricity. One of the factors of high efficiency of this type of gas turbine is the increase of its turbine inlet temperature. As an effect of this factor and in conjunction with some other factors, the 1st stage nozzle of gas turbine operates under extremely high temperature and thermal stresses. As a result, the design lifetime of these components becomes limited. Furthermore, attention on nozzles or vanes is required in order to achieve their design lifetime. However, due to unfriendly operational condition and environmental effect, anytime failure can occur on these heat resistant alloy based components which may lead to severe damage of gas turbine. To mitigate these adverse effects, schedule maintenance is performed on a predetermined time interval of hot gas path components of gas turbine based power plant. This paper addresses common failures in gas turbine's 1st stage nozzles or vanes. Usually these are repaired by using ADH process but for several reasons ADH process is not used here. Hence the challenging task is performed using gas tungsten arc welding which is presented in this article systematically.

  6. Survey of SRF guns

    Energy Technology Data Exchange (ETDEWEB)

    Belomestnykh, S.

    2011-07-25

    Developing Superconducting RF (SRF) electron guns is an active field with several laboratories working on different gun designs. While the first guns were based on elliptic cavity geometries, Quarter Wave Resonator (QWR) option is gaining popularity. QWRs are especially well suited for producing beams with high charge per bunch. In this talk we will describe recent progress in developing both types of SRF guns. SRF guns made excellent progress in the last two years. Several guns generated beams and one, at HZDR, injected beam into an accelerator. By accomplishing this, HZDR/ELBE gun demonstrated feasibility of the SRF gun concept with a normal-conducting Cs{sub 2}Te cathode. The cathode demonstrated very good performance with the lifetime of {approx}1 year. However, for high average current/high bunch charge operation CsK{sub 2}Sb is preferred as it needs green lasers, unlike UV laser for the Cs{sub 2}Te, which makes it easier to build laser/optics systems. Other high QE photocathodes are being developed for SRF guns, most notably diamond-amplified photocathode. Several QWR guns are under development with one producing beam already. They are very promising for high bunch charge operation. The field is very active and we should expect more good results soon.

  7. Women and Guns. Firearm Facts.

    Science.gov (United States)

    Duker, Laurie, Ed.

    Many gun manufacturers market guns to women claiming a gun can provide protection. Statistics provided in this fact sheet indicate gun ownership may provide a false sense of security that can be fatal, since the greatest threat to a woman comes from the people and guns within her own home. Contrary to "typical" scenarios created by advertisers,…

  8. Monitoring of trace chloride ions at different stages of the gas production process

    Directory of Open Access Journals (Sweden)

    A.Y. El Naggar

    2015-01-01

    Full Text Available Fifty gas and liquid samples at different stages of Obaiyed gas plant in Egypt were selected and subjected for determining chloride ion and hydrocarbon compositions. The trace levels of chloride in the water extracted from natural gas, condensate, Benfield and glycol samples were achieved using ion chromatograph (IC, electrical, conductivity and potentiometric methods, respectively. The hydrocarbon compositions were analyzed and evaluated using capillary gas chromatography. The chloride ions in natural gas and condensate are a function of water content and their concentration mainly depends on the separation efficiency. Variability in natural gas and condensate compositions seasonally is not an uncommon occurrence. Our aim is monitoring of chloride ion to select and optimize the conditions of sweetening and dehydration regenerators in order to follow and prevent their gradient in gas plant.

  9. Carbon Nanotube Electron Gun

    Science.gov (United States)

    Nguyen, Cattien V. (Inventor); Ribaya, Bryan P. (Inventor)

    2013-01-01

    An electron gun, an electron source for an electron gun, an extractor for an electron gun, and a respective method for producing the electron gun, the electron source and the extractor are disclosed. Embodiments provide an electron source utilizing a carbon nanotube (CNT) bonded to a substrate for increased stability, reliability, and durability. An extractor with an aperture in a conductive material is used to extract electrons from the electron source, where the aperture may substantially align with the CNT of the electron source when the extractor and electron source are mated to form the electron gun. The electron source and extractor may have alignment features for aligning the electron source and the extractor, thereby bringing the aperture and CNT into substantial alignment when assembled. The alignment features may provide and maintain this alignment during operation to improve the field emission characteristics and overall system stability of the electron gun.

  10. Study of a plasma produced in a neutral gas chamber by the injection of a beam generated by a coaxial gun

    International Nuclear Information System (INIS)

    Castell, R.; Sanchez, A.; Mandelbaum, D.

    1982-01-01

    The design and operation of a plasma coaxial gun is described. The penetration and characteristics of the plasma emitted by the gun propagating in a expansion chamber with helium at 40 feBar is analyzed. The diagnostics is made with a double Langmuir probe observing the time variation of the electronic density along the propagation axis. Optical spectroscopy is used to measure one of the emission lines of the plasma radiation propaganting in the medium. The space-time description of the ion distribution function in a free-force field is made by the fit of an analytical model. (L.C.) [pt

  11. Theoretical evaluation of the efficiency of gas single-stage reciprocating compressor medium pressure units

    Science.gov (United States)

    Busarov, S. S.; Vasil'ev, V. K.; Busarov, I. S.; Titov, D. S.; Panin, Ju. N.

    2017-08-01

    Developed earlier and tested in such working fluid as air, the technology of calculating the operating processes of slow-speed long-stroke reciprocating stages let the authors to obtain successful results concerning compression of gases to medium pressures in one stage. In this connection, the question of the efficiency of the application of slow-speed long-stroke stages in various fields of technology and the national economy, where the working fluid is other gas or gas mixture, is topical. The article presents the results of the efficiency evaluation of single-stage compressor units on the basis of such stages for cases when ammonia, hydrogen, helium or propane-butane mixture is used as the working fluid.

  12. Staged fracturing of horizontal shale gas wells with temporary plugging by sand filling

    Directory of Open Access Journals (Sweden)

    Xing Liang

    2017-03-01

    Full Text Available Due to downhole complexities, shale-gas horizontal well fracturing in the Sichuan Basin suffered from casing deformation and failure to apply the technique of cable-conveyed perforation bridge plug. In view of these problems, a new technique of staged volume fracturing with temporary plugging by sand filling is employed. Based on theoretical analyses and field tests, a design of optimized parameters of coiled tubing-conveyed multi-cluster sand-blasting perforation and temporary plugging by sand filling was proposed. It was applied in the horizontal Well ZJ-1 in which casing deformation occurred. The following results are achieved in field operations. First, this technique enables selective staged fracturing in horizontal sections. Second, this technique can realize massive staged fracturing credibly without mechanical plugging, with the operating efficiency equivalent to the conventional bridge plug staged fracturing. Third, full-hole is preserved after fracturing, thus it is possible to directly conduct an open flow test without time consumption of a wiper trip. The staged volume fracturing with temporary plugging by sand filling facilitated the 14-stage fracturing in Well ZJ-1, with similar SRV to that achieved by conventional bridge plug staged fracturing and higher gas yield than neighboring wells on the same well pad. Thus, a new and effective technique is presented in multi-cluster staged volume fracturing of shale gas horizontal wells.

  13. Stage 1: Expression of interest and consultation document for natural gas distribution in New Brunswick

    International Nuclear Information System (INIS)

    1998-01-01

    The New Brunswick government intends to award a franchise to establish natural gas distribution in the province. To this end, the province wishes to invite bids from qualified entities to establish gas distribution facilities. The province will select the preferred bidder(s) through a two-stage competitive bidding process. This document details the province's policy objectives, questions and issues to be addressed in stage 1 of the process, and the schedule for the process. Appendices include copies of relevant provincial statutes and regulations

  14. Development of plasma cathode electron guns

    Science.gov (United States)

    Oks, Efim M.; Schanin, Peter M.

    1999-05-01

    The status of experimental research and ongoing development of plasma cathode electron guns in recent years is reviewed, including some novel upgrades and applications to various technological fields. The attractiveness of this kind of e-gun is due to its capability of creating high current, broad or focused beams, both in pulsed and steady-state modes of operation. An important characteristic of the plasma cathode electron gun is the absence of a thermionic cathode, a feature which leads to long lifetime and reliable operation even in the presence of aggressive background gas media and at fore-vacuum gas pressure ranges such as achieved by mechanical pumps. Depending on the required beam parameters, different kinds of plasma discharge systems can be used in plasma cathode electron guns, such as vacuum arcs, constricted gaseous arcs, hollow cathode glows, and two kinds of discharges in crossed E×B fields: Penning and magnetron. At the present time, plasma cathode electron guns provide beams with transverse dimension from fractional millimeter up to about one meter, beam current from microamperes to kiloamperes, beam current density up to about 100 A/cm2, pulse duration from nanoseconds to dc, and electron energy from several keV to hundreds of keV. Applications include electron beam melting and welding, surface treatment, plasma chemistry, radiation technologies, laser pumping, microwave generation, and more.

  15. Rethinking Gun Violence

    OpenAIRE

    Greenberg, Mark; Litman, Harry

    2010-01-01

    This working paper develops the argument of "Gun Violence and Gun Control" (also posted on SSRN), a short piece commissioned by the London Review of Books. We decided not to publish either paper, in part because we felt there were empirical issues that we were not in a position to assess. We welcome comments on either paper. In this Article, we propose a new way of approaching the problem of gun violence, synthesizing features of a number of successful initiatives. We begin, in Pa...

  16. CNG7 Consolidated Nail Gun

    OpenAIRE

    DeSantis, Christopher Daniel

    2015-01-01

    The purpose of my study is to create a compact, portable nail gun. The nail gun is to be used in tight spaces where hammers, pneumatic nail guns, and portable nail guns will not fit. The intended market is for homeowners renovating their houses. The short length and lightweight, compact frame make the CNG7 ideal for this market. The CNG7 is designed with minimum material waste and fewer parts than other nail guns. MARCH

  17. Serbian society and gun culture

    OpenAIRE

    Cvetković Vladimir

    2006-01-01

    This paper questions whether one characteristic of Serbian society is a gun culture. The first part of the paper deals with some theoretical concerns and closer explanation of what is understood by the term gun culture. Few different approaches to the issue are analyzed. The concept used has three main components of the gun culture: system of positive beliefs; social symbols embodied by the gun; agent "bearers" of gun culture. The second part of the paper presents results from Small Arms and ...

  18. Gun Dynamics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Gun Dynamics Laboratory is a research multi-task facility, which includes two firing bays, a high bay area and a second floor laboratory space. The high bay area...

  19. Teen Suicide and Guns

    Science.gov (United States)

    ... Health Issues Listen Text Size Email Print Share Teen Suicide and Guns Page Content Article Body Protect ... thinking of a passing problem, not the outcome! Teen Suicide—A Big Problem Suicide is one of ...

  20. Gun control saves lives.

    Science.gov (United States)

    Matzopoulos, Richard

    2016-05-19

    Reducing firearm mortality by means of stricter gun control is one of the most important short- to medium-term measures to address the burden of violence in South Africa, while longer-term interventions and policy measures take effect.

  1. Calculating effective gun policies

    OpenAIRE

    Wodarz, D; Komarova, NL

    2017-01-01

    Following recent shootings in the USA, a debate has erupted, one side favoring stricter gun control, the other promoting protection through more weapons. We provide a scientific foundation to inform this debate, based on mathematical, epidemiological models that quantify the dependence of firearm-related death rates of people on gun policies. We assume a shooter attacking a single individual or a crowd. Two strategies can minimize deaths in the model, depending on parameters...

  2. Gun Control Legislation

    Science.gov (United States)

    2010-08-27

    under the Constitution? Does gun control help reduce violent crime? Would household, street corner, and schoolyard disputes be less lethal if firearms...instructions, searching existing data sources, gathering and maintaining the data needed , and completing and reviewing the collection of information...household, street corner, and schoolyard disputes be less lethal if firearms were more difficult and expensive to acquire? Would more restrictive gun

  3. Alcoholism and gun control.

    Science.gov (United States)

    el-Guebaly, N; Lee, M

    1977-08-01

    The recurring dilemma of having to deal with an intoxicated person in possession of a gun uttering homicidal or suicidal threats along with the current debate on gun control prompted this controlled survey of the characteristics of individuals with problems arising from the joint abuse of alcohol and possession of a gun. A comparison of the data point to violence as being the most significant differentiating variable involved. This violent potential was reflected by the presence among the alcoholics involved of more past and present antisocial traits, a higher rating on the Nicol's scale of violence, more offences committed against the person and homicidal behaviour. The availability of a gun was a significant factor. No correlation was found between the severity of the drinking problem and the risk of dangerous handling of a gun. The need for more stringent gun controls is supported but their implications to the physician and especially the psychiatrist as a potential guarantor for a licence application ought to be further explored by the professional bodies involved.

  4. NEW GUN CAPABILITY WITH INTERCHANGABLE BARRELS TO INVESTIGATE LOW VELOCITY IMPACT REGIMES AT THE LAWRENCE LIVERMORE NATIONAL LABORATORY HIGH EXPLOSIVES APPLICATIONS FACILITY

    Energy Technology Data Exchange (ETDEWEB)

    Vandersall, K S; Behn, A; Gresshoff, M; Jr., L F; Chiao, P I

    2009-09-16

    A new gas gun capability is being activated at Lawrence Livermore National Laboratories located in the High Explosives Applications Facility (HEAF). The single stage light gas (dry air, nitrogen, or helium) gun has interchangeable barrels ranging from 25.4 mm to 76.2 mm in diameter with 1.8 meters in length and is being fabricated by Physics Applications, Inc. Because it is being used for safety studies involving explosives, the gun is planned for operation inside a large enclosed firing tank, with typical velocities planned in the range of 10-300 m/s. Three applications planned for this gun include: low velocity impact of detonator or detonator/booster assemblies with various projectile shapes, the Steven Impact test that involves impact initiation of a cased explosive target, and the Taylor impact test using a cylindrical explosive sample impacted onto a rigid anvil for fracture studies of energetic materials. A highlight of the gun features, outline on work in progress for implementing this capability, and discussion of the planned areas of research will be included.

  5. A method for measuring the local gas pressure within a gas-flow stage in situ in the transmission electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Colby, R. [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA (United States); Alsem, D.H. [Hummingbird Scientific, Lacey, WA (United States); Liyu, A.; Kabius, B. [Environmental Molecular Sciences Laboratory, Pacific Northwest National Laboratory, Richland, WA (United States)

    2015-06-15

    Environmental transmission electron microscopy (TEM) has enabled in situ experiments in a gaseous environment with high resolution imaging and spectroscopy. Addressing scientific challenges in areas such as catalysis, corrosion, and geochemistry can require pressures much higher than the ∼20 mbar achievable with a differentially pumped environmental TEM. Gas flow stages, in which the environment is contained between two semi-transparent thin membrane windows, have been demonstrated at pressures of several atmospheres. However, the relationship between the pressure at the sample and the pressure drop across the system is not clear for some geometries. We demonstrate a method for measuring the gas pressure at the sample by measuring the ratio of elastic to inelastic scattering and the defocus of the pair of thin windows. This method requires two energy filtered high-resolution TEM images that can be performed during an ongoing experiment, at the region of interest. The approach is demonstrated to measure greater than atmosphere pressures of N{sub 2} gas using a commercially available gas-flow stage. This technique provides a means to ensure reproducible sample pressures between different experiments, and even between very differently designed gas-flow stages. - Highlights: • Method developed for measuring gas pressure within a gas-flow stage in the TEM. • EFTEM and CTF-fitting used to calculate amount and volume of gas. • Requires only a pair of images without leaving region of interest. • Demonstrated for P > 1 atm with a common commercial gas-flow stage.

  6. A method for measuring the local gas pressure within a gas-flow stage in situ in the transmission electron microscope

    International Nuclear Information System (INIS)

    Colby, R.; Alsem, D.H.; Liyu, A.; Kabius, B.

    2015-01-01

    Environmental transmission electron microscopy (TEM) has enabled in situ experiments in a gaseous environment with high resolution imaging and spectroscopy. Addressing scientific challenges in areas such as catalysis, corrosion, and geochemistry can require pressures much higher than the ∼20 mbar achievable with a differentially pumped environmental TEM. Gas flow stages, in which the environment is contained between two semi-transparent thin membrane windows, have been demonstrated at pressures of several atmospheres. However, the relationship between the pressure at the sample and the pressure drop across the system is not clear for some geometries. We demonstrate a method for measuring the gas pressure at the sample by measuring the ratio of elastic to inelastic scattering and the defocus of the pair of thin windows. This method requires two energy filtered high-resolution TEM images that can be performed during an ongoing experiment, at the region of interest. The approach is demonstrated to measure greater than atmosphere pressures of N 2 gas using a commercially available gas-flow stage. This technique provides a means to ensure reproducible sample pressures between different experiments, and even between very differently designed gas-flow stages. - Highlights: • Method developed for measuring gas pressure within a gas-flow stage in the TEM. • EFTEM and CTF-fitting used to calculate amount and volume of gas. • Requires only a pair of images without leaving region of interest. • Demonstrated for P > 1 atm with a common commercial gas-flow stage

  7. Implementation of Exhaust Gas Recirculation for Double Stage Waste Heat Recovery System on Large Container Vessel

    DEFF Research Database (Denmark)

    Andreasen, Morten; Marissal, Matthieu; Sørensen, Kim

    2014-01-01

    to reach the highest possible combination of pressure and temperature, and adapted to Tier III by introducing two alternative superheaters. The system design is optimized and found capable of producing from 400 to 1900 kW, with a weighted average power of 958 kW. The consumption profile is found...... of recovering some of the waste heat from the exhaust gas. This heat is converted into electrical energy used on-board instead of using auxiliary engines. Exhaust Gas Recirculation (EGR) systems, are recirculating a part of the exhaust gas through the engine combustion chamber to reduce emissions. WHRS combined...... with EGR is a potential way to improve system efficiency while reducing emissions. This paper investigates the feasibility of combining the two systems. EGR dilutes the fuel, lowering the combustion temperature and thereby the formation of NOx, to reach Tier III limitation. A double stage WHRS is set up...

  8. Computational Study on the Effect of Shroud Shape on the Efficiency of the Gas Turbine Stage

    Science.gov (United States)

    Afanas'ev, I. V.; Granovskii, A. V.

    2018-03-01

    The last stages of powerful power gas turbines play an important role in the development of power and efficiency of the whole unit as well as in the distribution of the flow parameters behind the last stage, which determines the efficient operation of the exhaust diffusers. Therefore, much attention is paid to improving the efficiency of the last stages of gas turbines as well as the distribution of flow parameters. Since the long blades of the last stages of multistage high-power gas turbines could fall into the resonance frequency range in the course of operation, which results in the destruction of the blades, damping wires or damping bolts are used for turning out of resonance frequencies. However, these damping elements cause additional energy losses leading to a reduction in the efficiency of the stage. To minimize these losses, dampening shrouds are used instead of wires and bolts at the periphery of the working blades. However, because of the strength problems, designers have to use, instead of the most efficient full shrouds, partial shrouds that do not provide for significantly reducing the losses in the tip clearance between the blade and the turbine housing. In this paper, a computational study is performed concerning an effect that the design of the shroud of the turbine-working blade exerted on the flow structure in the vicinity of the shroud and on the efficiency of the stage as a whole. The analysis of the flow structure has shown that a significant part of the losses under using the shrouds is associated with the formation of vortex zones in the cavities on the turbine housing before the shrouds, between the ribs of the shrouds, and in the cavities at the outlet behind the shrouds. All the investigated variants of a partial shrouding are inferior in efficiency to the stages with shrouds that completely cover the tip section of the working blade. The stage with a unshrouded working blade was most efficient at the values of the relative tip clearance

  9. An economic model of gun control

    OpenAIRE

    O' Sullivan, Arthur

    1998-01-01

    Guns stolen from law-abiding households provide the principal source of guns for criminals. The lethality of crime instruments increases with the availability of guns, so the gun market is subject to externalities that generate excessive ownership and inadequate spending on protective measures to deter gun theft. One motive for gun ownership is self defense, and the gun market is subject to coordination failure: the more guns purchased lawfully, the more will be stolen by crimi...

  10. The PLX- α Plasma Guns: Progress and Plans

    Science.gov (United States)

    Witherspoon, F. D.; Brockington, S.; Case, A.; Cruz, E.; Luna, M.; Thio, Y. C. Francis; LANL PLX-α Team

    2017-10-01

    The ALPHA coaxial plasma guns are being developed to support a 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion (PJMIF). Seven complete guns have been delivered to LANL with 6 guns currently undergoing simultaneous test firings on PLX. The guns are designed to operate over a range of parameters: 0.5-5.0 mg of Ar, Ne, N2, Kr, and Xe; 20-60 km/s; 2 × 1016 cm-3 muzzle density; and up to 7.5 kJ stored energy per gun. Each coaxial gun incorporates a fast dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured coaxial gap to suppress the blow-by instability. Optimizing parameter scans performed at HyperV have achieved : 4 mg at >50 km/s and length of 10 cm. Peak axial density 30 cm from the muzzle is 2 ×1016 cm-3. We will provide an overview of the experimental results, along with plans for further improvements in reliability, maintainability, fabricability, and plasma jet performance, with the latter focused on further improvements in the fast gas valve and the ignitors. This work supported by the ARPA-E ALPHA Program under contract DE-AR0000566 and Strong Atomics, LLC.

  11. Electromagnetic Guns versus Conventional Guns - a performance comparison

    NARCIS (Netherlands)

    Reus, N.M. de; Weijden, J. van der

    1993-01-01

    Performance improvement is one of the key issues of Electromagnetic gun systems compared to conventional gun systems. Due to higher muzzle velocities, the gun's fire control computer will be able to predict the target's future position more accurately because prediction time will be smaller. In this

  12. Fueling by coaxial plasma guns

    International Nuclear Information System (INIS)

    Marshall, J.

    1978-01-01

    The operating principles of pulsed coaxial guns are reviewed. Some problems involved with the injection of plasma beams from these guns into containment fields are described. The injection during reactor operating conditions is then discussed

  13. Where the guns come from: the gun industry and gun commerce.

    Science.gov (United States)

    Wintemute, Garen J

    2002-01-01

    Under federal law, it is illegal for youth under age 18 to purchase rifles or shotguns, and for those under age 21 to purchase handguns. However, fatality and injury statistics clearly show that guns are finding their way into young people's hands. Many of these youth obtain guns through illegal gun markets. This article focuses on how guns in the United States are manufactured, marketed, and sold. The article shows how the legal and illegal gun markets are intimately connected and make guns easily accessible to youth. Although the domestic gun manufacturing industry is relatively small and has experienced declining sales in recent years, it has significant political clout and a large market for its products, and has engaged in aggressive marketing to youth. Lax oversight of licensed firearms dealers, combined with little or no regulation of private sales between gun owners, mean that guns can quickly moved from the legal gun market into the illegal market, where they can be acquired by young people. Certain guns, especially inexpensive, poorly made small handguns, are particularly attractive to criminals and youth. The author observes that several policy innovations--including increased regulation of licensed firearms dealers, intensified screening of prospective buyers, regulation of private sales, gun licensing and registration, and bans on some types of weapons--hold promise for decreasing the flow of guns into the hands of youth.

  14. Unbalanced field RF electron gun

    Science.gov (United States)

    Hofler, Alicia

    2013-11-12

    A design for an RF electron gun having a gun cavity utilizing an unbalanced electric field arrangement. Essentially, the electric field in the first (partial) cell has higher field strength than the electric field in the second (full) cell of the electron gun. The accompanying method discloses the use of the unbalanced field arrangement in the operation of an RF electron gun in order to accelerate an electron beam.

  15. CAPE TOWN'S TIME-GUNS

    African Journals Online (AJOL)

    Although a great many articles have been writ- ten on the subject of Cape Town's noon gun (the. official terminology is 'time-gun') most of the writ- ers have not had access to the Lion Battery Fort. Record Book and the existance of more than one. Cape Town time-gun has only recently been re- corded. By 1807 a noon gun ...

  16. Children, Youth, and Gun Violence.

    Science.gov (United States)

    Behrman, Richard E., Ed.

    2002-01-01

    This collection of articles summarizes knowledge and research about how gun violence affects children and youth and discusses which policies hold promise for reducing youth gun violence. The papers are: (1) "Statement of Purpose" (Richard E. Behrman); "Children, Youth, and Gun Violence: Analysis and Recommendations" (Kathleen…

  17. The gas-liquid mass transfer coefficient (k(L)a) in the gas-liquid Multi-stage Agitated Contactor (MAC)

    NARCIS (Netherlands)

    Breman, B.B; Beenackers, A.A C M; Bouma, M.J; VanderWerf, M.H.

    1996-01-01

    Data on the volumetric liquid-side gas-liquid mass transfer coefficient, k(L)a, in a Multi-stage Agitated Contractor (MAC) are reported for three gas-liquid systems (air-water, helium-n-octane, and air-Monoethylene Glycol (MEG)). k(L)a (s(-1)) was determined using a dynamic method with moderately

  18. Guns, Germs and Steel

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 6; Issue 1. Guns, Germs and Steel - A Short History of Everybody for the Last 13,000 years. Suri Venkatachalam. Book Review Volume 6 ... Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/006/01/0084-0088 ...

  19. 120 Hz Gun Review

    Energy Technology Data Exchange (ETDEWEB)

    Colby, E.

    2005-01-31

    The review was held at SLAC on September 11 and 12, 2001. Presentations concerning the thermal analysis, mechanical design, integration with the laser and accelerator, general beam dynamics considerations, a load lock mechanism, and symmetric power feed options comprised the review. Slides from these presentations are available elsewhere. The review committee was charged with evaluating the 120 Hz gun design including proposed load lock and power feed options and recommending improvements. Broader evaluation of the injector as a whole (including focusing and diagnostic systems that do no impact the envelope of the gun itself) is expected to be covered in a future review and will not be commented on here. In general, the long operational experience with four generations of s-band RF guns at numerous labs worldwide has led to considerable experience in design, fabrication, and operation aspects, and provides an excellent base on which to design the higher duty factor LCLS injector. While open questions remain on obtaining the design performance from these injectors, the microwave design of the gun has reached a state of relative maturity.

  20. Gun Internal Ballistics.

    Science.gov (United States)

    An approximate method of analysis is formulated for gun internal ballistics. The method is incorporated in a digital computer program which is...described. The validity of the method of analysis and computational procedure is substantiated by comparison of theoretical results with experimental

  1. Gun control saves lives

    African Journals Online (AJOL)

    implementation of laws encompassing multiple firearm restrictions in certain countries. The authors cited, alongside examples from the. USA, Canada, Australia, New Zealand and Brazil, SA's FCA, which banned certain types of firearm, required training tests for licences, additional licences for each gun owned, increased ...

  2. Gun Dealers, USA.

    Science.gov (United States)

    Duker, Laurie; And Others

    In the United States, more than 11,500 adolescents' and young adults' lives are taken each year by firearms. Although Federal law prohibits minors from purchasing handguns, they typically get them by asking someone of legal age (18 years or older) to purchase them from one of the 256,771 Federally licensed gun dealers. This pamphlet answers…

  3. Radar gun hazards

    Energy Technology Data Exchange (ETDEWEB)

    1991-12-20

    Radar guns - hand-held units used by the law to nail speeders - have been in use since the early '60s. Now they've been accused of causing cancer. Police officers in several states have so far filed eight suits against the manufacturer, claiming that they have contracted rare forms of cancer, such as of the eyelid and the testicle, from frequent proximity to the devices. Spurred by concerns expressed by police groups, researchers at the Rochester Institute of Technology are conducting what they believe to be the first research of its kind in the nation. Last month psychologist John Violanti, an expert in policy psychology and health, sent out a one-page survey to 6,000 active and retired police officers in New York State, asking them about their health and their use of radar guns. Violanti says melanoma, leukemia, and lymph node cancer may be linked to these as well as other electromagnetic devices. The Food and Drug Administration earlier this year issued a warning about radar guns, telling users not to operate them closer than 6 inches from the body. But this may not be a sufficient safeguard since the instruments can give off crisscrossing wave emissions within a police vehicle. The survey will be used to help determine if it would be safer to mount the guns, which are currently either hand-held or mounted on dashboards, outside troopers' cars.

  4. Guns, Germs and Steel

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 6; Issue 1. Guns, Germs and Steel - A Short History of Everybody for the Last 13,000 years. Suri Venkatachalam. Book Review Volume 6 Issue 1 January 2001 pp 84-88. Fulltext. Click here to view fulltext PDF. Permanent link:

  5. Reliability Omnipotent Analysis For First Stage Separator On The Separation Process Of Gas, Oil And Water

    International Nuclear Information System (INIS)

    Sony Tjahyani, D. T.; Ismu W, Puradwi; Asmara Santa, Sigit

    2001-01-01

    Reliability of industry can be evaluated based on two aspects which are risk and economic aspects. From these points, optimation value can be determined optimation value. Risk of the oil refinery process are fire and explosion, so assessment of this system must be done. One system of the oil refinery process is first stage separator which is used to separate gas, oil and water. Evaluation of reliability for first stage separator system has been done with FAMECA and HAZap method. The analysis results, the probability of fire and explosion of 1.1x10 - 2 3 /hour and 1.2x10 - 1 1 /hour, respectively. The reliability value of the system is high because each undesired event is anticipated with safety system or safety component

  6. Staged fuel and air injection in combustion systems of gas turbines

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, Michael John; Berry, Jonathan Dwight

    2018-04-10

    A gas turbine including a working fluid flowpath extending aftward from a forward injector in a combustor. The combustor may include an inner radial wall, an outer radial wall, and, therebetween, a flow annulus, and a third radial wall formed about the outer radial wall that forms an outer flow annulus. A staged injector may intersect the flow annulus so to attain an injection point within the working fluid flowpath by which aftward and forward annulus sections are defined. Air directing structure may include an aftward intake section corresponding to the aftward annulus section and a forward intake section corresponding to the forward annulus section. The air directing structure may include a switchback coolant flowpath to direct air from the compressor discharge cavity to the staged injector. The switchback coolant flowpath may include an upstream section through the flow annulus, and a downstream section through the outer flow annulus.

  7. Development of the Antares electron gun

    International Nuclear Information System (INIS)

    Stine, R.; Leland, W.; Mansfield, C.; Rosocha, L.; Jansen, J.; Gibson, R.; Allen, G.

    1984-01-01

    Antares is the Los Alamos National Laboratory 40-kJ, 1-ns, CO 2 laser system that is now operational. This laser system was developed for the Intertial Confinement Fusion (ICF) program and is beginning target experiments. The distributed circuit modeling, design and operation of the large electron gun developed for the final laser power amplifier are reviewed. This gun is significant because of the large electron current area, 9 m 2 ; the number of emitter blades, 48; the dual cathode current return; and the coaxial geometry and grid control. The gun components and their development are discussed. These include the emitter blades, the coaxial grid (to maintain constant electron current during the 5-μs pulse), the bonded stacked-ring insulator (to electrically insulate the grid/cathode), the Kapton/aluminum electron transmission windows (to provide an interface between gun vacuum and laser gas) and the vacuum shell (operated at a vacuum of 10 -6 torr). A unique pressure diagnostic is also discussed

  8. The study on a gas-coupled two-stage stirling-type pulse tube cryocooler

    Science.gov (United States)

    Wu, X. L.; Chen, L. B.; Zhu, X. S.; Pan, C. Z.; Guo, J.; Wang, J. J.; Zhou, Y.

    2017-12-01

    A two-stage gas-coupled Stirling-type pulse tube cryocooler (SPTC) driven by a linear dual-opposed compressor has been designed, manufactured and tested. Both of the stages adopted coaxial structure for compactness. The effect of a cold double-inlet at the second stage on the cooling performance was investigated. The test results show that the cold double-inlet will help to achieve a lower cooling temperature, but it is not conducive to achieving a higher cooling capacity. At present, without the cold double-inlet, the second stage has achieved a no-load temperature of 11.28 K and a cooling capacity of 620 mW/20 K with an input electric power of 450 W. With the cold double-inlet, the no-load temperature is lowered to 9.4 K, but the cooling capacity is reduced to 400 mW/20 K. The structure of the developed cryocooler and the influences of charge pressure, operating frequency and hot end temperature will also be introduced in this paper.

  9. Study of gas production from shale reservoirs with multi-stage hydraulic fracturing horizontal well considering multiple transport mechanisms

    OpenAIRE

    Guo, Chaohua; Wei, Mingzhen; Liu, Hong

    2018-01-01

    Development of unconventional shale gas reservoirs (SGRs) has been boosted by the advancements in two key technologies: horizontal drilling and multi-stage hydraulic fracturing. A large number of multi-stage fractured horizontal wells (MsFHW) have been drilled to enhance reservoir production performance. Gas flow in SGRs is a multi-mechanism process, including: desorption, diffusion, and non-Darcy flow. The productivity of the SGRs with MsFHW is influenced by both reservoir conditions and hyd...

  10. A two-stage biological gas to liquid transfer process to convert carbon dioxide into bioplastic

    KAUST Repository

    Al Rowaihi, Israa

    2018-03-06

    The fermentation of carbon dioxide (CO2) with hydrogen (H2) uses available low-cost gases to synthesis acetic acid. Here, we present a two-stage biological process that allows the gas to liquid transfer (Bio-GTL) of CO2 into the biopolymer polyhydroxybutyrate (PHB). Using the same medium in both stages, first, acetic acid is produced (3.2 g L−1) by Acetobacterium woodii from 5.2 L gas-mixture of CO2:H2 (15:85 v/v) under elevated pressure (≥2.0 bar) to increase H2-solubility in water. Second, acetic acid is converted to PHB (3 g L−1 acetate into 0.5 g L−1 PHB) by Ralstonia eutropha H16. The efficiencies and space-time yields were evaluated, and our data show the conversion of CO2 into PHB with a 33.3% microbial cell content (percentage of the ratio of PHB concentration to cell concentration) after 217 h. Collectively, our results provide a resourceful platform for future optimization and commercialization of a Bio-GTL for PHB production.

  11. Engineering design of the PLX- α coaxial gun

    Science.gov (United States)

    Cruz, E.; Brockington, S.; Case, A.; Luna, M.; Witherspoon, F. D.; Thio, Y. C. Francis; PLX-α Team

    2017-10-01

    We describe the engineering and technical improvements, as well as provide a detailed overview of the design choices, of the latest PLX- α coaxial gun designed for the 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion. Each coaxial gun incorporates a fast, dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured gap designed to suppress the blow-by instability. The evolution of the latest Alpha gun is presented with emphasis on its upgraded performance. Changes include a faster more robust gas valve, better-quality ceramic insulator material and enhancements to overall design layout. These changes result in a gun with increased repeatability, reduced potential failure modes, improved fault tolerance and better than expected efficiency. A custom 600- μF, 5-kV pfn and a set of six inline sparkgap switches operated in parallel are mounted directly to the back of the gun, and are designed to reduce inductance, cost, and complexity, maximize efficiency and system reliability, and ensure symmetric current flow. This work supported by the ARPA-E ALPHA Program under contract DE-AR0000566 and Strong Atomics, LLC.

  12. High voltage processing of the SLC polarized electron gun

    International Nuclear Information System (INIS)

    Saez, P.; Clendenin, J.; Garden, C.; Hoyt, E.; Klaisner, L.; Prescott, C.; Schultz, D.; Tang, H.

    1993-04-01

    The SLC polarized electron gun operates at 120 kV with very low dark current to maintain the ultra high vacuum (UHV). This strict requirement protects the extremely sensitive photocathode from contaminants caused by high voltage (HV) activity. Thorough HV processing is thus required x-ray sensitive photographic film, a nanoammeter in series with gun power supply, a radiation meter, a sensitive residual gas analyzer and surface x-ray spectrometry were used to study areas in the gun where HV activity occurred. By reducing the electric field gradients, carefully preparing the HV surfaces and adhering to very strict clean assembly procedures, we found it possible to process the gun so as to reduce both the dark current at operating voltage and the probability of HV discharge. These HV preparation and processing techniques are described

  13. Mole gun injury.

    Science.gov (United States)

    Pistré, V; Rezzouk, J

    2013-09-01

    A mole gun is a weapon, which is used to trap and kill moles. This report provides an overview of the state of knowledge of mole gun injuries, comparable to blast injuries caused by fireworks, explosive or gunshot. Over a 2-year period, the authors reported their experience with ten hand injuries caused by mole gun. Radial side of the hand was often concerned, particularly the thumb. The authors explain their choices in the management of such lesions. Surgery was performed primarily and a large debridement currently seemed to offer the best outcome for the patient. Blast, crush, burns and lacerations may explain the higher rate of amputation to the digits. A long period of physiotherapy, specifically of the hand, was needed before the patient could return to work. This ballistic hand trauma encountered by surgeons requires knowledge and understanding of these injuries. It should be in accordance with firearms law because of severe injuries encountered and possible lethal wounds. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  14. Leveling off the energy demand. Air conditioning by town gas NEXT STAGE. Energy juyo no heijunka wo motomete. Gas reibo NEXT STAGE

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, K. (Keio Univ., Tokyo (Japan). Faculty of Science and Technology)

    1994-07-01

    Utilizing various types of energy with combining them rationally is now drawing attention. One of these types of energy is the town gas. The air conditioning by town gas draws a special attention. The town gas is characterized by environmental conservation, energy saving, and comfortability. The town gas does not contain sulfur compounds which cause the acid rain. The town gas produces the least amount of carbon dioxide among all the fossil fuel. The air conditioning by the town gas is getting popular. Examples are Tokyo Dome in Tokyo, Pavilion Plaza, a new shopping spot in Fukuoka, Umeda Sky Building in Osaka, Dai-ich Apparel Center in Tokyo, Ohno Memorial Hospital in Osaka, Nagoya Municipal Integrated Stadium in Nagoya, Meguro-Gajoen in Tokyo, and New Yomiuri-Shimbun Building in Sapporo. 41 figs.

  15. Wisconsin SRF Electron Gun Commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Bisognano, Joseph J. [University of Wisconsin-Madison; Bissen, M. [University of Wisconsin-Madison; Bosch, R. [University of Wisconsin-Madison; Efremov, M. [University of Wisconsin-Madison; Eisert, D. [University of Wisconsin-Madison; Fisher, M. [University of Wisconsin-Madison; Green, M. [University of Wisconsin-Madison; Jacobs, K. [University of Wisconsin-Madison; Keil, R. [University of Wisconsin-Madison; Kleman, K. [University of Wisconsin-Madison; Rogers, G. [University of Wisconsin-Madison; Severson, M. [University of Wisconsin-Madison; Yavuz, D. D. [University of Wisconsin-Madison; Legg, Robert A. [JLAB; Bachimanchi, Ramakrishna [JLAB; Hovater, J. Curtis [JLAB; Plawski, Tomasz [JLAB; Powers, Thomas J. [JLAB

    2013-12-01

    The University of Wisconsin has completed fabrication and commissioning of a low frequency (199.6 MHz) superconducting electron gun based on a quarter wave resonator (QWR) cavity. Its concept was optimized to be the source for a CW free electron laser facility. The gun design includes active tuning and a high temperature superconducting solenoid. We will report on the status of the Wisconsin SRF electron gun program, including commissioning experience and first beam measurements.

  16. Power and efficiency in a regenerative gas-turbine cycle with multiple reheating and intercooling stages

    Science.gov (United States)

    Calvo Hernández, A.; Roco, J. M. M.; Medina, A.

    1996-06-01

    Using an improved Brayton cycle as a model, a general analysis accounting for the efficiency and net power output of a gas-turbine power plant with multiple reheating and intercooling stages is presented. This analysis provides a general theoretical tool for the selection of the optimal operating conditions of the heat engine in terms of the compressor and turbine isentropic efficiencies and of the heat exchanger efficiency. Explicit results for the efficiency, net power output, optimized pressure ratios, maximum efficiency, maximum power, efficiency at maximum power, and power at maximum efficiency are given. Among others, the familiar results of the Brayton cycle (one compressor and one turbine) and of the corresponding Ericsson cycle (infinite compressors and infinite turbines) are obtained as particular cases.

  17. Co-axial electrodes gun characteristics

    International Nuclear Information System (INIS)

    Masoud, M.M.; Soliman, H.M.

    1981-01-01

    A coaxial electrodes gun is constructed with inner electrode diameter of 3.2 cm; outer electrode diameter of 6.6 cm and length of 25 cm it is connected to a condenser bank which delivers 4 K joule stored energy. The maximum power of the discharge is equal to 4.5x10 4 K watt; for 5 KV charging voltage. The inductance showed two main peak values of 0.257μH and 0.27μH. Theoretical calculations using one-dimension-single fluid model is μ sed, which shows that the maximum acceleration is at 0.5 sec, and the gas breakdown takes place at the gun breech; at the start of the discharge, will leave the gun after 1.625μ sec, also the drift velocity, the force and the magnetic field are given. The measured results show quite reasonable agreement with the calculations for most of the results, and the position of the plasma sheath inside the gun slightly deviated from the theoretical calculations due to viscosity and wall interaction, as well as other parameters which did not be take into consideration. The plasma current density of the sheath has its maximum value at Z=18 cm, the plasma will leave the coaxial source after 1.5μ sec, from the start of the discharge, which conferms with the theoretical model. Resistance of the gas between the electrodes, changes with time according to the particle injected from this source, and the maximum efficiency of the installation for charging voltage 5kV and pressure 80μ Hg is at approx.=10μ sec and 20.5μ sec

  18. The ALS Gun Electronics system

    International Nuclear Information System (INIS)

    Lo, C.C.

    1993-05-01

    The ALS Gun Electronics system has been designed to accommodate gun with a custom made socket and high speed electronics circuit which is capable of producing single and multiple electron bunches with time jitters measured at better than 50 PS. The system generates the gated RF signal at ground level before sending it up to the 120 KV-biased gun deck via a fiber optic cable. The current pulse width as a function of grid bias, using an Eimac 8847A planar triode simulating an electron gun, was measured to show the relationship between the two parameters

  19. Biolistic DNA delivery to mice with the low pressure gene gun.

    Science.gov (United States)

    Yen, Meng-Chi; Lai, Ming-Derg

    2013-01-01

    Biolistic DNA delivery is an approach to deliver plasmid to culture cells, plants, or animals. Plasmid DNA is usually transferred through bombardment of DNA-coated particles by highly pressurized gas in various kinds of delivery vehicles. The low pressure gene gun can deliver plasmid at lower pressure. Here, we describe methods of biolistic DNA delivery to mice using the low pressure gene gun.

  20. Rotating-bed reactor as a power source for EM gun applications

    Energy Technology Data Exchange (ETDEWEB)

    Powell, J.; Botts, T.; Stickley, C.M.; Meth, S.

    1980-01-01

    Electromagnetic gun applications of the Rotating Bed Reactor (RBR) are examined. The RBR is a compact (approx. 1 m/sup 3/), (up to several thousand MW(th)), high-power reactor concept, capable of producing a high-temperature (up to approx. 300/sup 0/K) gas stream with a MHD generator coupled to it, the RBR can generate electric power (up to approx. 1000 MW(e)) in the pulsed or cw modes. Three EM gun applications are investigated: a rail gun thruster for orbit transfer, a rapid-fire EM gun for point defense, and a direct ground-to-space launch. The RBR appears suitable for all applications.

  1. Rotating-bed reactor as a power source for EM gun applications

    International Nuclear Information System (INIS)

    Powell, J.; Botts, T.; Stickley, C.M.; Meth, S.

    1980-01-01

    Electromagnetic gun applications of the Rotating Bed Reactor (RBR) are examined. The RBR is a compact (approx. 1 m 3 ), (up to several thousand MW(th)), high-power reactor concept, capable of producing a high-temperature (up to approx. 300 0 K) gas stream with a MHD generator coupled to it, the RBR can generate electric power (up to approx. 1000 MW(e)) in the pulsed or cw modes. Three EM gun applications are investigated: a rail gun thruster for orbit transfer, a rapid-fire EM gun for point defense, and a direct ground-to-space launch. The RBR appears suitable for all applications

  2. Understanding and Predicting Gun Barrel Erosion

    National Research Council Canada - National Science Library

    Johnston, Ian A

    2005-01-01

    The Australian Defence Force will soon have to contend with gun barrel erosion issues arising from the use of new low-vulnerability gun propellants, the acquisition of new ammunition and gun systems...

  3. Development of laser heated high current DC electron gun

    International Nuclear Information System (INIS)

    Banerjee, Srutarshi; Bhattacharjee, Dhruva; Kandaswamy, E.; Ghodke, S.R.; Tiwari, Rajnish; Bakhtsingh, R.I.

    2015-01-01

    The paper deals with the development of a Laser heated cathode for Electron Accelerator. The electron gun is meant for Megawatt-class DC Accelerator for Electron Beam Flue Gas Treatment applications. Conventionally, LaB 6 cathode is indirectly heated by tungsten filaments whereas in the newly proposed gun, Laser is utilized for heating. A Nd:YAG Laser is used to heat the LaB 6 cathode to emission temperatures. The characterization of cathode heating at various Laser powers has been carried out. In initial trials, it has been observed that with 125 W of Laser power, the LaB 6 pellet was heated to 1315 ° C. Based on these experimental results, an electron gun rated for 30 kV, 350 mA CW has been designed. The optimization of gun electrode geometry has been done using CST Particle Studio in order to tune the various electron gun parameters. The beam diameter obtained in simulation is 8 mm at 100 mm from the LaB 6 cathode. The perveance obtained is 7.1 x 10 -8 A/V 3/2 . The Laser heated cathode has the advantages of eliminating the magnetic field effects of filament on the electron beam, electrical isolation needed for gun filament power supplies and better electron beam emittances. (author)

  4. Gun Concerns Personal for Duncan

    Science.gov (United States)

    McNeil, Michele

    2013-01-01

    As U.S. Secretary of Education Arne Duncan works with other Obama administration officials on policy responses to the shootings at a Connecticut elementary school, he brings a personal and professional history that has acquainted him with the impact of gun violence. As schools chief in Chicago from 2001 to 2008, he was affected by the gun deaths…

  5. Gun violence trends in movies

    NARCIS (Netherlands)

    Bushman, B.J.; Jamieson, P.E.; Weitz, I.; Romer, D.

    2013-01-01

    BACKGROUND: Many scientific studies have shown that the mere presence of guns can increase aggression, an effect dubbed the "weapons effect." The current research examines a potential source of the weapons effect: guns depicted in top-selling films. METHODS: Trained coders identified the presence of

  6. Numerical Study of the Working Process in the Reducing Gas Generator of the Upper Stage Oxygen - Methane Engine

    Directory of Open Access Journals (Sweden)

    D. M. Yagodnikov

    2015-01-01

    Full Text Available This article deals with the problems of creating a reducing gas generator of the liquid rocket engine (LRE of upper stage using advanced fuel components, namely oxygen + liquid natural gas. Relevance of the work is justified by the need to create and develop of environmentally friendly missile systems for space applications using methane-based fuel (liquid natural gas. As compared to the currently used unsymmetrical dimethyl-hydrazine and kerosene, this fuel is environmentally safe, passive to corrosion, has better cooling properties and high energy characteristics in the re-generatively cooled chambers, as well as is advantageous for LRE of multiple start and use.The purpose of this work is a mathematical modeling, calculation of the working process efficiency, as well as study of gas-dynamic structure of the flow in the gas generator flow path. The object of study is the upper stage LRE gas generator, which uses the reducing scheme on the liquid propellants: oxygen + liquid methane. Research methods are based on numerical simulation.Computational studies allowed us to receive the velocity, temperatures, and concentrations of reactants and combustion products in the longitudinal section of gas generator. Analysis of the gas-dynamic structure of flow shows a complete equalization of the velocity field by 2/3 of the gas generator length. Thus, the same distance is not enough to equalize the temperature distribution of the gasification products and their concentrations in radius. Increasing the total excess oxidant ratio from 0.15 to 0.25 leads to a greater spread of the parameters at the exit of the gas generator by ~ 13 ÷ 17%. As a recommendation to reduce the size of the working area, is proposed a dual-zone gas generator-mixing scheme with fuel separately supplied to the first and second zones.

  7. LCLS Gun Solenoid Design Considerations

    International Nuclear Information System (INIS)

    Schmerge, John

    2010-01-01

    The LCLS photocathode rf gun requires a solenoid immediately downstream for proper emittance compensation. Such a gun and solenoid have been operational at the SSRL Gun Test Facility (GTF) for over eight years. Based on magnetic measurements and operational experience with the GTF gun solenoid multiple modifications are suggested for the LCLS gun solenoid. The modifications include adding dipole and quadrupole correctors inside the solenoid, increasing the bore to accommodate the correctors, decreasing the mirror plate thickness to allow the solenoid to move closer to the cathode, cutouts in the mirror plate to allow greater optical clearance with grazing incidence cathode illumination, utilizing pancake coil mirror images to compensate the first and second integrals of the transverse fields and incorporating a bipolar power supply to allow for proper magnet standardization and quick polarity changes. This paper describes all these modifications plus the magnetic measurements and operational experience leading to the suggested modifications.

  8. Preventing gun injuries in children.

    Science.gov (United States)

    Crossen, Eric J; Lewis, Brenna; Hoffman, Benjamin D

    2015-02-01

    Firearms are involved in the injury and death of a large number of children each year from both intentional and unintentional causes. Gun ownership in homes with children is common, and pediatricians should incorporate evidence-based means to discuss firearms and protect children from gun-related injuries and violence. Safe storage of guns, including unloaded guns locked and stored separately from ammunition, can decrease risks to children, and effective tools are available that pediatricians can use in clinical settings to help decrease children's access to firearms. Furthermore, several community-based interventions led by pediatricians have effectively reduced firearm-related injury risks to children. Educational programs that focus on children's behavior around guns have not proven effective. © American Academy of Pediatrics, 2015. All rights reserved.

  9. Electric arc welding gun

    Science.gov (United States)

    Luttrell, Edward; Turner, Paul W.

    1978-01-01

    This invention relates to improved apparatus for arc welding an interior joint formed by intersecting tubular members. As an example, the invention is well suited for applications where many similar small-diameter vertical lines are to be welded to a long horizontal header. The improved apparatus includes an arc welding gun having a specially designed welding head which is not only very compact but also produces welds that are essentially free from rolled-over solidified metal. The welding head consists of the upper end of the barrel and a reversely extending electrode holder, or tip, which defines an acute angle with the barrel. As used in the above-mentioned example, the gun is positioned to extend upwardly through the vertical member and the joint to be welded, with its welding head disposed within the horizontal header. Depending on the design of the welding head, the barrel then is either rotated or revolved about the axis of the vertical member to cause the electrode to track the joint.

  10. Guns and sleep

    Directory of Open Access Journals (Sweden)

    Quan SF

    2015-08-01

    Full Text Available No abstract available. Article truncated at 150 words. Gun deaths are a problem in America. Irrespective of one’s position on gun control, the statistics do not lie. According to the Centers for Disease Control and Prevention (CDC, there were 11,208 deaths caused by firearms in 2013 (1. The recent high profile cases in Cincinnati, OH, Lafayette, LA and Memphis, TN further highlight the issue. Obviously, each case of death by a firearm had its own set of underlying factors that contributed to the final fatal outcome, but one wonders whether sleep deprivation can be implicated in some of them. Sleep duration in adults over the past approximately 30 years has been declining in the United States (2. A variety of reasons can be cited as underlying causes such as greater use of artificial lighting, an expanding 24 hour non-stop society, promotion of a work ethic that values “burning the midnight oil”, and use of electronic devices before bedtime ...

  11. Experimental study of a staged combustion system for stationary gas turbine applications

    Science.gov (United States)

    Lamont, Warren G.

    Two optically accessible experimental test rigs were designed and constructed to investigate a staged or distributed combustion system for stationary gas turbine applications. The test rigs were fuelled with natural gas and featured two combustion zones: the main combustion zone (MCZ) and the secondary combustion zone (SCZ). The MCZ is a swirl stabilized dump combustor and the SCZ, which is axially downstream from the MCZ, is formed by a transverse jet injecting a premixed fuel/air mixture into the vitiated stream. After installing and commissioning the test rig, an emission survey was conducted to investigate the SCZ conditions, equivalence ratio and momentum ratio, that produce low NOx emissions and give a higher temperature rise before a simulated high pressure turbine than firing only the MCZ. The emission survey found several operating conditions that show the benefit of combustion staging. These beneficial conditions had an SCZ equivalence ratio between 0.41 and 1.12. The data from the emission survey was then used to create an artificial neural network (ANN). The ANN used a multi-layer feed-forward network architecture and was trained with experimental data using the backpropagation training algorithm. The ANN was then used to create performance maps and optimum operational regions were sought. Lastly, optical diagnostics were used to obtain information on the nature of the SCZ reactive jet. The diagnostics included high speed CH* chemiluminescence, OH planar laser induced fluorescence (PLIF) and dual-pump coherent anti-Stokes Raman scattering (CARS). The chemiluminescence and PLIF were used to qualitatively determine the size and shape of the transverse jet reaction zone. Dual-pump CARS was used to quantitatively determine the temperature and H2/N2 concentration ratio profile at the mid-plane of the transverse jet. Dual-pump CARS data was collected for four operating conditions but only one is presented in this dissertation. For the condition presented, the

  12. Gun Shows and Gun Violence: Fatally Flawed Study Yields Misleading Results

    Science.gov (United States)

    Hemenway, David; Webster, Daniel; Pierce, Glenn; Braga, Anthony A.

    2010-01-01

    A widely publicized but unpublished study of the relationship between gun shows and gun violence is being cited in debates about the regulation of gun shows and gun commerce. We believe the study is fatally flawed. A working paper entitled “The Effect of Gun Shows on Gun-Related Deaths: Evidence from California and Texas” outlined this study, which found no association between gun shows and gun-related deaths. We believe the study reflects a limited understanding of gun shows and gun markets and is not statistically powered to detect even an implausibly large effect of gun shows on gun violence. In addition, the research contains serious ascertainment and classification errors, produces results that are sensitive to minor specification changes in key variables and in some cases have no face validity, and is contradicted by 1 of its own authors’ prior research. The study should not be used as evidence in formulating gun policy. PMID:20724672

  13. Gun shows and gun violence: fatally flawed study yields misleading results.

    Science.gov (United States)

    Wintemute, Garen J; Hemenway, David; Webster, Daniel; Pierce, Glenn; Braga, Anthony A

    2010-10-01

    A widely publicized but unpublished study of the relationship between gun shows and gun violence is being cited in debates about the regulation of gun shows and gun commerce. We believe the study is fatally flawed. A working paper entitled "The Effect of Gun Shows on Gun-Related Deaths: Evidence from California and Texas" outlined this study, which found no association between gun shows and gun-related deaths. We believe the study reflects a limited understanding of gun shows and gun markets and is not statistically powered to detect even an implausibly large effect of gun shows on gun violence. In addition, the research contains serious ascertainment and classification errors, produces results that are sensitive to minor specification changes in key variables and in some cases have no face validity, and is contradicted by 1 of its own authors' prior research. The study should not be used as evidence in formulating gun policy.

  14. Optimization of 2‑Stage Turbocharged Gas SI Engine Under Steady State Operation

    Directory of Open Access Journals (Sweden)

    Vítek Oldřich

    2017-12-01

    Full Text Available The proposed paper deals with an optimization of a highly-turbocharged large-bore gas SI engine. Only steady state operation (constant engine speed and load is considered. The paper is mainly focused on theoretical potential of 2-stage turbocharging concept in terms of performance and limitation. The results are obtained by means of simulation using complex 0-D/ 1-D engine model including the control algorithm. Different mixture composition concepts are considered to satisfy different levels of NOx limit - fresh air mixed with external cooled EGR is supposed to be the right approach while optimal EGR level is to be found. Considering EGR circuit, 5 different layouts are tested to select the best design. As the engine control is relatively complex (2-sage turbocharger group, external EGR, compressor blow-by, controlled air excess, 5 different control means of boost pressure were considered. Each variant based on above mentioned options is optimized in terms of compressor/turbine size (swallowing capacity to obtain the best possible BSFC. The optimal variants are compared and general conclusions are drawn.

  15. The Effects of Gun Ownership Rates and Gun Control Laws on Suicide Rates

    OpenAIRE

    Mark Gius

    2011-01-01

    The purpose of the present study is to determine the effects of gun control laws and gun ownership rates on state-level suicide rates. Using the most recent data on suicide rates, gun control measures, and gun ownership rates, the results of the present study suggest that states that require handgun permits have lower gun-related suicide rates, and states that have higher gun ownership rates have higher gun-related suicide rates. Regarding non-gun suicides, results suggest that stricter gun c...

  16. Gun violence trends in movies.

    Science.gov (United States)

    Bushman, Brad J; Jamieson, Patrick E; Weitz, Ilana; Romer, Daniel

    2013-12-01

    Many scientific studies have shown that the mere presence of guns can increase aggression, an effect dubbed the "weapons effect." The current research examines a potential source of the weapons effect: guns depicted in top-selling films. Trained coders identified the presence of violence in each 5-minute film segment for one-half of the top 30 films since 1950 and the presence of guns in violent segments since 1985, the first full year the PG-13 rating (age 13+) was used. PG-13-rated films are among the top-selling films and are especially attractive to youth. Results found that violence in films has more than doubled since 1950, and gun violence in PG-13-rated films has more than tripled since 1985. When the PG-13 rating was introduced, these films contained about as much gun violence as G (general audiences) and PG (parental guidance suggested for young children) films. Since 2009, PG-13-rated films have contained as much or more violence as R-rated films (age 17+) films. Even if youth do not use guns, these findings suggest that they are exposed to increasing gun violence in top-selling films. By including guns in violent scenes, film producers may be strengthening the weapons effect and providing youth with scripts for using guns. These findings are concerning because many scientific studies have shown that violent films can increase aggression. Violent films are also now easily accessible to youth (e.g., on the Internet and cable). This research suggests that the presence of weapons in films might amplify the effects of violent films on aggression.

  17. Plural beam electron gun assembly

    International Nuclear Information System (INIS)

    Stratton, M.G.

    1977-01-01

    The invention relates to a cathode ray tube plural-beam-in-line bi-potential electron gun assembly, having applied beam currents of differing levels, manifests structurally modified gun structures to effect focused beam landings at the screen that are evidenced as substantially equi-sized spots thereby providing improved resolution and brightness of the screen imagery. The structural changes embody modifications of the related focusing and accelerator electrodes of the respective guns to provide a partial telescoping arrangement for effecting the discrete placement, forming and shielding of the final focusing lenses. The three lenses so formed are in different planes in partial overlapping axial relationship

  18. Superconducting augmented rail gun (SARG)

    International Nuclear Information System (INIS)

    Homan, C.G.; Cummings, C.E.; Fowler, C.M.

    1986-01-01

    Superconducting augmentation consists of a superconducting coil operating in the persistent mode closely coupled magnetically with a normally conducting rail gun. A theoretical investigation of the effect of this system on a rail gun has shown that two benefits occur. Projectile velocities and launch efficiencies increase significantly depending on the magnetic coupling between the rail and augmentation circuits. Previous work evaluated an idealized system by neglecting energy dissipation effects. In this paper, the authors extend the analysis to include the neglected terms and show improved actual launch efficiencies for the SARG configuration. In this paper, the authors discuss details of projectile design in depth and present preliminary results of rail gun performance

  19. Gun barrel erosion - Comparison of conventional and LOVA gun propellants

    NARCIS (Netherlands)

    Hordijk, A.C.; Leurs, O.

    2006-01-01

    The research department Energetic Materials within TNO Defence, Security and Safety is involved in the development and (safety and insensitive munitions) testing of conventional (nitro cellulose based) and thermoplastic elastomer (TPE) based gun propellants. Recently our testing capabilities have

  20. Temporal association between federal gun laws and the diversion of guns to criminals in Milwaukee.

    Science.gov (United States)

    Webster, Daniel W; Vernick, Jon S; Bulzacchelli, Maria T; Vittes, Katherine A

    2012-02-01

    The practices of licensed gun dealers can threaten the safety of urban residents by facilitating the diversion of guns to criminals. In 2003, changes to federal law shielded gun dealers from the release of gun trace data and provided other protections to gun dealers. The 14-month period during which the dealer did not sell junk guns was associated with a 68% reduction in the diversion of guns to criminals within a year of sale by the dealer and a 43% increase in guns diverted to criminals following sales by other dealers. The laws were associated with a 203% increase in the number of guns diverted to criminals within a year of sale by the gun store, which was the focus of this study. Policies which affect gun dealer accountability appeared to influence the diversion of guns to criminals.

  1. Simulation of a process for the two-stage thermal conversion of biomass into the synthesis gas

    Science.gov (United States)

    Kosov, V. F.; Lavrenov, V. A.; Zaichenko, V. M.

    2015-11-01

    The paper presents results of simulation of a process for the two-stage thermal conversion of wood biomass into the synthesis gas. The first stage of process is pyrolysis of raw materials, the second stage is cracking of volatile pyrolysis products which blown through the char at a temperature of about 1000° C. Char is a porous biomass residue with carbon content about 90%. The simulation based on the results of experimental investigations of a pilot plant with capacity up to 50 kg of raw material per hour. The main result of simulation is estimation of an energy conversion efficiency of wood biomass into synthesis gas for three different operation modes. The first mode is conversion of biomass into fuel gas and char, and the char is not further used. The second mode is the same, but char used as fuel for producing heat for own demand of the process. The third mode includes gasification of char by means of water steam, aimed to obtaining an additional yield of synthesis gas. The simulation shown, that total efficiency of power plant was 17.1% in the first mode, 22.4% in the second mode and 22.6% in the third mode.

  2. Reverse Ballistic Air Gun Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This custom-designed facility houses a suite of three air guns capable of generating accelerations up to 100,000 Gs and velocities up to 2,000 ft/s. In addition to a...

  3. NASA-Ames vertical gun

    Science.gov (United States)

    Schultz, P. H.

    1984-01-01

    A national facility, the NASA-Ames vertical gun range (AVGR) has an excellent reputation for revealing fundamental aspects of impact cratering that provide important constraints for planetary processes. The current logistics in accessing the AVGR, some of the past and ongoing experimental programs and their relevance, and the future role of this facility in planetary studies are reviewed. Publications resulting from experiments with the gun (1979 to 1984) are listed as well as the researchers and subjects studied.

  4. Thermodynamic analysis and optimization of a two-stage organic Rankine cycle for liquefied natural gas cryogenic exergy recovery

    International Nuclear Information System (INIS)

    Xue, Xiaodi; Guo, Cong; Du, Xiaoze; Yang, Lijun; Yang, Yongping

    2015-01-01

    A two-stage ORC (organic Rankine cycle) is proposed, by which low-grade heat of exhaust flue gas of a 123.5 MW gas-steam combined cycle power generating unit, as well as the cryogenic energy of LNG (liquefied natural gas) can be effectively recovered and utilized. R227ea and R116 are selected as working fluids for the system. Based on the thermodynamic mathematical models, the effects of key design parameters, including that of turbine inlet pressures, mass flow rates of working fluids and outlet steam fractions of evaporators on the system performance are investigated from the view of both thermodynamics and economics with CPP (cost per net power output) as the objective function. The results obtained the optimal inlet pressure of turbines, under which, the CPP has the minimum value. It is found that the CPP also decreases with the mass flow rate of R227ea and R116. The rate of absorbed heat in top cycle to that in bottom cycle has a positive impact on CPP, but very weak. The optimized two-stage ORC system can output net work with 1776.44 kW with the thermal efficiency of 25.64% and exergy efficiency of 31.02%. Cost per net power output is 6.3$/W, while the LNG temperature can be raised to 283.15 K. - Highlights: • Two-stage organic Rankine cycle is proposed to recover both exhaust heat of flue gas and LNG cryogenic exergy. • Flue gas from a gas-steam combined cycle power plant and LNG are employed as heat source and heat sink, respectively. • Thermodynamic and economic mathematical models are established. • Parameter optimization is studied and optimal design with the CPP of 6.3$/W is obtained. • Effects of key thermodynamic design parameters on system performance are investigated

  5. State Gun Policy and Cross-State Externalities: Evidence from Crime Gun Tracing

    OpenAIRE

    Brian Knight

    2013-01-01

    This paper provides a theoretical and empirical analysis of cross-state externalities associated with gun regulations in the context of the gun trafficking market. Using gun tracing data, which identify the source state for crime guns recovered in destination states, we find that firearms in this market tend to flow from states with weak gun laws to states with strict gun laws, satisfying a necessary condition for the existence of cross-state externalities in the theoretical model. We also fi...

  6. State Gun Law Environment and Youth Gun Carrying in the United States.

    Science.gov (United States)

    Xuan, Ziming; Hemenway, David

    2015-11-01

    Gun violence and injuries pose a substantial threat to children and youth in the United States. Existing evidence points to the need for interventions and policies for keeping guns out of the hands of children and youth. (1) To examine the association between state gun law environment and youth gun carrying in the United States, and (2) to determine whether adult gun ownership mediates this association. This was a repeated cross-sectional observational study design with 3 years of data on youth gun carrying from US states. The Youth Risk Behavior Survey comprises data of representative samples of students in grades 9 to 12 from biennial years of 2007, 2009, and 2011. We hypothesized that states with more restrictive gun laws have lower rates of youth gun carrying, and this association is mediated by adult gun ownership. State gun law environment as measured by state gun law score. Youth gun carrying was defined as having carried a gun on at least 1 day during the 30 days before the survey. In the fully adjusted model, a 10-point increase in the state gun law score, which represented a more restrictive gun law environment, was associated with a 9% decrease in the odds of youth gun carrying (adjusted odds ratio [AOR], 0.91 [95% CI, 0.86-0.96]). Adult gun ownership mediated the association between state gun law score and youth gun carrying (AOR, 0.94 [ 95% CI, 0.86-1.01], with 29% attenuation of the regression coefficient from -0.09 to -0.07 based on bootstrap resampling). More restrictive overall gun control policies are associated with a reduced likelihood of youth gun carrying. These findings are relevant to gun policy debates about the critical importance of strengthening overall gun law environment to prevent youth gun carrying.

  7. Temporal Association between Federal Gun Laws and the Diversion of Guns to Criminals in Milwaukee

    OpenAIRE

    Webster, Daniel W.; Vernick, Jon S.; Bulzacchelli, Maria T.; Vittes, Katherine A.

    2012-01-01

    The practices of licensed gun dealers can threaten the safety of urban residents by facilitating the diversion of guns to criminals. In 2003, changes to federal law shielded gun dealers from the release of gun trace data and provided other protections to gun dealers. The 14-month period during which the dealer did not sell junk guns was associated with a 68% reduction in the diversion of guns to criminals within a year of sale by the dealer and a 43% increase in guns diverted to criminals fol...

  8. The case for moderate gun control.

    Science.gov (United States)

    DeGrazia, David

    2014-03-01

    In addressing the shape of appropriate gun policy, this essay assumes for the sake of discussion that there is a legal and moral right to private gun ownership. My thesis is that, against the background of this right, the most defensible policy approach in the United States would feature moderate gun control. The first section summarizes the American gun control status quo and characterizes what I call "moderate gun control." The next section states and rebuts six leading arguments against this general approach to gun policy. The section that follows presents a positive case for moderate gun control that emphasizes safety in the home and society as well as rights whose enforcement entails some limits or qualifications on the right to bear arms. A final section shows how the recommended gun regulations address legitimate purposes, rather than imposing arbitrary restrictions on gun rights, and offers concluding reflections.

  9. Large Bore Powder Gun Qualification (U)

    Energy Technology Data Exchange (ETDEWEB)

    Rabern, Donald A. [Los Alamos National Laboratory; Valdiviez, Robert [Los Alamos National Laboratory

    2012-04-02

    A Large Bore Powder Gun (LBPG) is being designed to enable experimentalists to characterize material behavior outside the capabilities of the NNSS JASPER and LANL TA-55 PF-4 guns. The combination of these three guns will create a capability to conduct impact experiments over a wide range of pressures and shock profiles. The Large Bore Powder Gun will be fielded at the Nevada National Security Site (NNSS) U1a Complex. The Complex is nearly 1000 ft below ground with dedicated drifts for testing, instrumentation, and post-shot entombment. To ensure the reliability, safety, and performance of the LBPG, a qualification plan has been established and documented here. Requirements for the LBPG have been established and documented in WE-14-TR-0065 U A, Large Bore Powder Gun Customer Requirements. The document includes the requirements for the physics experiments, the gun and confinement systems, and operations at NNSS. A detailed description of the requirements is established in that document and is referred to and quoted throughout this document. Two Gun and Confinement Systems will be fielded. The Prototype Gun will be used primarily to characterize the gun and confinement performance and be the primary platform for qualification actions. This gun will also be used to investigate and qualify target and diagnostic modifications through the life of the program (U1a.104 Drift). An identical gun, the Physics Gun, will be fielded for confirmatory and Pu experiments (U1a.102D Drift). Both guns will be qualified for operation. The Gun and Confinement System design will be qualified through analysis, inspection, and testing using the Prototype Gun for the majority of process. The Physics Gun will be qualified through inspection and a limited number of qualification tests to ensure performance and behavior equivalent to the Prototype gun. Figure 1.1 shows the partial configuration of U1a and the locations of the Prototype and Physics Gun/Confinement Systems.

  10. Combustion Light Gas Gun Technology Demonstration

    Science.gov (United States)

    2007-01-23

    laser detectors (visible beyond the barrel in Figure 19) determined the projectile velocity. Propellant Loading Propellant gases can be loaded...supply line valves will close and the vents are open. Figure 10 shows the solenoid bank that controls the nitrogen supply to each pneumatic valve...with ordinary hydrogen, nor can the conditions that trigger nuclear fusion in a hydrogen bomb occur in a hydrogen accident; they’re achieved, with

  11. Combustion Light Gas Gun Technology Demonstration

    National Research Council Canada - National Science Library

    Kruczynski, D; Massey, D; Milligan, R; Vigil, E; Landers, B; Meneguzzi, M

    2007-01-01

    .... For the Navy Barrage round fired from a 155mm bore CLGG, the predicted range is up to 200 nm, sufficient to provide effective amphibious and in-shore fire support without endangering capital assets...

  12. Creativity under the gun.

    Science.gov (United States)

    Amabile, Teresa M; Hadley, Constance N; Kramer, Steven J

    2002-08-01

    If you're like most managers, you've worked with people who swear they do their most creative work under tight deadlines. You may use pressure as a management technique, believing it will spur people on to great leaps of insight. You may even manage yourself this way. If so, are you right? Not necessarily, these researchers say. There are instances where ingenuity flourishes under extreme time pressure--for instance, a NASA team within hours comes up with a primitive but effective fix for the failing air filtration system aboard Apollo 13. But when creativity is under the gun, it usually ends up getting killed, the authors say. They recently took a close look at how people experience time pressure, collecting and analyzing more than 9,000 daily diary entries from individuals who were working on projects that required high levels of creativity and measuring their ability to innovate under varying levels of time pressure. The authors describe common characteristics of time pressure and outline four working environments under which creativity may or may not flourish. High-pressure days that still yield creativity are full of focus and meaningful urgency--people feel like they are on a mission. High-pressure days that yield no creativity lack such focus--people feel like they are on a treadmill, forced to switch gears often. On low-pressure days that yield creativity, people feel like they are on an expedition--exploring ideas rather than just identifying problems. And on low-pressure days that yield no creative thinking, people work on autopilot--doing their jobs without engaging too deeply. Managers should avoid extreme time pressure when possible; after all, complex cognitive processing takes time. For when they can't, the authors suggest ways to mollify its effects.

  13. Study of gas production from shale reservoirs with multi-stage hydraulic fracturing horizontal well considering multiple transport mechanisms.

    Directory of Open Access Journals (Sweden)

    Chaohua Guo

    Full Text Available Development of unconventional shale gas reservoirs (SGRs has been boosted by the advancements in two key technologies: horizontal drilling and multi-stage hydraulic fracturing. A large number of multi-stage fractured horizontal wells (MsFHW have been drilled to enhance reservoir production performance. Gas flow in SGRs is a multi-mechanism process, including: desorption, diffusion, and non-Darcy flow. The productivity of the SGRs with MsFHW is influenced by both reservoir conditions and hydraulic fracture properties. However, rare simulation work has been conducted for multi-stage hydraulic fractured SGRs. Most of them use well testing methods, which have too many unrealistic simplifications and assumptions. Also, no systematical work has been conducted considering all reasonable transport mechanisms. And there are very few works on sensitivity studies of uncertain parameters using real parameter ranges. Hence, a detailed and systematic study of reservoir simulation with MsFHW is still necessary. In this paper, a dual porosity model was constructed to estimate the effect of parameters on shale gas production with MsFHW. The simulation model was verified with the available field data from the Barnett Shale. The following mechanisms have been considered in this model: viscous flow, slip flow, Knudsen diffusion, and gas desorption. Langmuir isotherm was used to simulate the gas desorption process. Sensitivity analysis on SGRs' production performance with MsFHW has been conducted. Parameters influencing shale gas production were classified into two categories: reservoir parameters including matrix permeability, matrix porosity; and hydraulic fracture parameters including hydraulic fracture spacing, and fracture half-length. Typical ranges of matrix parameters have been reviewed. Sensitivity analysis have been conducted to analyze the effect of the above factors on the production performance of SGRs. Through comparison, it can be found that hydraulic

  14. Study of gas production from shale reservoirs with multi-stage hydraulic fracturing horizontal well considering multiple transport mechanisms.

    Science.gov (United States)

    Guo, Chaohua; Wei, Mingzhen; Liu, Hong

    2018-01-01

    Development of unconventional shale gas reservoirs (SGRs) has been boosted by the advancements in two key technologies: horizontal drilling and multi-stage hydraulic fracturing. A large number of multi-stage fractured horizontal wells (MsFHW) have been drilled to enhance reservoir production performance. Gas flow in SGRs is a multi-mechanism process, including: desorption, diffusion, and non-Darcy flow. The productivity of the SGRs with MsFHW is influenced by both reservoir conditions and hydraulic fracture properties. However, rare simulation work has been conducted for multi-stage hydraulic fractured SGRs. Most of them use well testing methods, which have too many unrealistic simplifications and assumptions. Also, no systematical work has been conducted considering all reasonable transport mechanisms. And there are very few works on sensitivity studies of uncertain parameters using real parameter ranges. Hence, a detailed and systematic study of reservoir simulation with MsFHW is still necessary. In this paper, a dual porosity model was constructed to estimate the effect of parameters on shale gas production with MsFHW. The simulation model was verified with the available field data from the Barnett Shale. The following mechanisms have been considered in this model: viscous flow, slip flow, Knudsen diffusion, and gas desorption. Langmuir isotherm was used to simulate the gas desorption process. Sensitivity analysis on SGRs' production performance with MsFHW has been conducted. Parameters influencing shale gas production were classified into two categories: reservoir parameters including matrix permeability, matrix porosity; and hydraulic fracture parameters including hydraulic fracture spacing, and fracture half-length. Typical ranges of matrix parameters have been reviewed. Sensitivity analysis have been conducted to analyze the effect of the above factors on the production performance of SGRs. Through comparison, it can be found that hydraulic fracture

  15. Coaxial-gun design and testing for the PLX- α Project

    Science.gov (United States)

    Witherspoon, F. Douglas; Brockington, Samuel; Case, Andrew; Cruz, Edward; Luna, Marco; Langendorf, Samuel

    2016-10-01

    We describe the Alpha coaxial gun designed for a 60-gun scaling study of spherically imploding plasma liners as a standoff driver for plasma-jet-driven magneto-inertial fusion (PJMIF). The guns operate over a range of parameters: 0.5-5.0 mg of Ar, Ne, N2, Kr, and Xe; 20-60 km/s; 2 × 1016 cm-3 muzzle density; and up to 7.5 kJ stored energy per gun. Each coaxial gun incorporates a fast dense gas injection and triggering system, a compact low-weight pfn with integral sparkgap switching, and a contoured gap designed to suppress the blow-by instability. The latest design iteration incorporates a faster more robust gas valve, an improved electrode contour, a custom 600- μF, 5-kV pfn, and six inline sparkgap switches operated in parallel. The switch and pfn are mounted directly to the back of the gun and are designed to reduce inductance, cost, and complexity, maximize efficiency and system reliability, and ensure symmetric current flow. We provide a brief overview of the design choices, the projected performance over the parameter ranges mentioned above, and experimental results from testing of the PLX- α coaxial gun. This work supported by the ARPA-E ALPHA Program.

  16. ATA injector-gun calculations

    International Nuclear Information System (INIS)

    Paul, A.C.

    1981-01-01

    ATA is a pulsed, 50 ns 10 KA, 50 MeV linear induction electron accelerator at LLNL. The ETA could be used as an injector for ATA. However the possibility of building a new injector gun for ATA, raised the question as to what changes from the ETA gun in electrode dimensions or potentials, if any, should be considered. In this report the EBQ code results for the four electrode configurations are reviewed and an attempt is made to determine the geometrical scaling laws appropriate to these ETA type gun geometries. Comparison of these scaling laws will be made to ETA operation. The characteristic operating curves for these geometries will also be presented and the effect of washer position determined. It will be shown that emittance growth will impose a limitation on beam current for a given anode potential before the virtual cathode limit is reached

  17. Handmade guns in Trabzon, Turkey.

    Science.gov (United States)

    Yilmaz, Riza; Birincioğlu, Ismail; Uner, H Bulent; Erkol, Zerrin; Butun, Celal; Acikgoz, Dinc; Bulut, Erkut R

    2009-07-01

    A wide variety of handmade firearms have been involved in criminal cases in the city of Trabzon, Turkey. Although they are often very similar to commercially manufactured firearms in terms of design, loading and locking mechanisms, and cocking and firing arrangements, these guns are constructed from cheap materials and are not safe for firing. Handmade firearms manufactured in the Black Sea region of Turkey, particularly in the city of Trabzon, are similar to pistols manufactured by Browning, Luger, Star, Smith and Wesson, Berretta, and MAB. A total of 201 handmade guns referred to the Criminal Police Laboratories for examination from 2003 to 2005 were evaluated with respect to type, number of barrels, size and caliber, rifling, design, mechanism, operability, legality, and similarity to commercial models. We found that most of these handmade guns resembled commercial models in several aspects.

  18. Lasers for RF guns: Proceedings

    International Nuclear Information System (INIS)

    Srinivasan-Rao, T.

    1994-01-01

    In the past decade, laser driven RF guns have matured from a device under development to a proven source for high brightness and low emittance electron beams. The reliability of the electron beam from these sources is dictated by the laser system that drives it. In addition, capabilities of the laser systems play a vital role in the design of the electron source for future machines such as the TESLA and NLC. The purpose of this workshop was to provide a forum for discussing the design criteria for the laser systems so that the reliability of the existing sources could be improved and the future machines could be serviced. The Workshop brought together experts in RF Guns, accelerators, and lasers, from both the commercial and academic community. Most of the presentations, discussions and conclusions at the workshop are included in these proceedings. The contents are divided into three sections, Section I contains the invited talks that outline the requirements of the RF Guns and the capabilities of the laser systems to meet these requirements. Section II includes most of the papers presented in the poster session. These papers describe various laser systems used with electron guns, schemes to modify the laser beam profile to optimize the electron bunch, and computer simulations of electron trajectories. Section III contains the summaries of the working groups. As the summary section indicates, with sufficient feed back systems, the electron gun could be made to operate reliably with minimum downtime, using commercial lasers currently available. The design of laser systems for future colliders depend critically on the choice of the cathode m the gun and its efficiency. Tentative designs of laser systems for the TESLA test facility and LCLS had been drawn assuming a copper cathode. Using a more efficient cathode will ease the energy requirement of the laser and simplify the design. The individual papers have been cataloged separately elsewhere

  19. Automatic targeting of plasma spray gun

    International Nuclear Information System (INIS)

    Abbatiello, L.A.; Neal, R.E.

    1978-01-01

    A means for monitoring the material portion in the flame of a plasma spray gun during spraying operations is described. A collimated detector, sensitive to certain wavelengths of light emission, is used to locate the centroid of the material with each pass of the gun. The response from the detector is then relayed to the gun controller to be used to automatically realign the gun

  20. Unintentional Gun Deaths among Children. Firearm Facts.

    Science.gov (United States)

    Duker, Laurie, Ed.

    Children are at risk of being killed or injured by a gun if their parents own a gun because many guns obtained for self-defense are kept loaded and within reach of children. This brief fact sheet presents statistical information relating to accidental deaths involving young people and firearms. Safety measures are suggested for preventing…

  1. The effects of pulse pressure from seismic water gun technology on Northern Pike

    Science.gov (United States)

    Gross, Jackson A.; Irvine, Kathryn M.; Wilmoth, Siri K.; Wagner, Tristany L.; Shields, Patrick A; Fox, Jeffrey R.

    2013-01-01

    We examined the efficacy of sound pressure pulses generated from a water gun for controlling invasive Northern Pike Esox lucius. Pulse pressures from two sizes of water guns were evaluated for their effects on individual fish placed at a predetermined random distance. Fish mortality from a 5,620.8-cm3 water gun (peak pressure source level = 252 dB referenced to 1 μP at 1 m) was assessed every 24 h for 168 h, and damage (intact, hematoma, or rupture) to the gas bladder, kidney, and liver was recorded. The experiment was replicated with a 1,966.4-cm3 water gun (peak pressure source level = 244 dB referenced to 1 μP at 1 m), but fish were euthanized immediately. The peak sound pressure level (SPLpeak), peak-to-peak sound pressure level (SPLp-p), and frequency spectrums were recorded, and the cumulative sound exposure level (SELcum) was subsequently calculated. The SPLpeak, SPLp-p, and SELcum were correlated, and values varied significantly by treatment group for both guns. Mortality increased and organ damage was greater with decreasing distance to the water gun. Mortality (31%) by 168 h was only observed for Northern Pike exhibiting the highest degree of organ damage. Mortality at 72 h and 168 h postexposure was associated with increasing SELcum above 195 dB. The minimum SELcum calculated for gas bladder rupture was 199 dB recorded at 9 m from the 5,620.8-cm3 water gun and 194 dB recorded at 6 m from the 1,966.4-cm3water gun. Among Northern Pike that were exposed to the large water gun, 100% of fish exposed at 3 and 6 m had ruptured gas bladders, and 86% exposed at 9 m had ruptured gas bladders. Among fish that were exposed to pulse pressures from the smaller water gun, 78% exhibited gas bladder rupture. Results from these initial controlled experiments underscore the potential of water guns as a tool for controlling Northern Pike.

  2. Multiple soliton compression stages in mid-IR gas-filled hollow-core fibers

    DEFF Research Database (Denmark)

    Habib, Md Selim; Markos, Christos; Bang, Ole

    2017-01-01

    The light confinement inside hollow-core (HC) fibers filled with noble gases constitutes an efficient route to study interesting soliton-plasma dynamics [1]. More recently, plasma-induced soliton splitting at the self-compression point was observed in a gas-filled fiber in the near-IR [2]. However...

  3. Mathematical models of gas-dynamic and thermophysical processes in underground coal mining at different stages of mine development

    Directory of Open Access Journals (Sweden)

    М. В. Грязев

    2017-03-01

    Full Text Available New trends have been traced and the existing ones refined regarding filtration and diffusive motion of gases in coal beds and surrounding rock, spontaneous heating of coal and transport of gas traces by ventilation currents in operating coal mines. Mathematical models of gas-dynamic and thermophysical processes inside underworked territories after mine abandonment have been justified. Mathematical models are given for feasible air feeding of production and development areas, as well as for the development of geotechnical solutions to ensure gas-dynamic safety at every stage of coal mine operation. It is demonstrated that the use of high-performance equipment in the production and development areas requires more precise filtration equations used when assessing coal mine methane hazard. A mathematical model of pressure field of non-associated methane in the edge area of the coal seam has been justified. The model is based on one-dimensional hyperbolic equation and takes into consideration final rate of pressure distribution in the seam. Trends in gas exchange between mined-out spaces of high methane- and CO2-concentration mines with the earth surface have been refined in order to ensure environmental safety of underworked territories.

  4. Gas-exchange patterns of Mediterranean fruit fly Pupae (Diptera: Tephritidae): A tool to forecast developmental stage

    International Nuclear Information System (INIS)

    Nestel, D.; Nemny-Lavy, E.; Alchanatis, V.

    2007-01-01

    The pattern of gas-exchange (CO 2 emission) was investigated for developing Mediterranean fruit fly (medfly) Ceratitis capitata (Wiedemann) pupae incubated at different temperatures. This study was undertaken to explore the usefulness of gas-exchange systems in the determination of physiological age in developing pupae that are mass produced for sterile insect technique projects. The rate of CO 2 emission was measured in a closed flow-through system connected to commercial infrared gas analysis equipment. Metabolic activity (rate of CO 2 emission) was related to pupal eye-color, which is the current technique used to determine physiological age. Eye-color was characterized digitally with 3 variables (Hue, Saturation and Intensity), and color separated by discriminant analysis. The rate of CO 2 emission throughout pupal development followed a U-shape, with high levels of emission during pupariation, pupal transformation and final pharate adult stages. Temperature affected the development time of pupae, but not the basic CO 2 emission patterns during development. In all temperatures, rates of CO 2 emission 1 and 2 d before adult emergence were very similar. After mid larval-adult transition (e.g., phanerocephalic pupa), digital eye-color was significantly correlated with CO 2 emission. Results support the suggestion that gas-exchange should be explored further as a system to determine pupal physiological age in mass production of fruit flies. (author) [es

  5. Forecasting cracked collectors on anticlinal type structures at late stage of exploration in oil and gas area

    Science.gov (United States)

    Hasanov, M. A.; Aleksandrov, B. L.; Eljayev, A. S.; Ezirbaev, T. B.; Gatsaeva, S. S.

    2017-10-01

    The possibility of using complex information on morphological parameters of structures, block porosity and the reservoir pressure gradient over previously explored deposits for the development of a multidimensional equation for estimating secondary porosity is considered. This is examined by the example of reservoirs with secondary (fractured) porosity of the Upper Cretaceous carbonate deposits of the Tersko-Sunzhenskaya oil and gas bearing region of the Ciscaucasia. The use of this equation makes it possible to predict the magnitude of the secondary porosity on the anticlinal structures, which are newly discovered by seismic methods at a later stage of exploration in the relevant oil and gas region, as a quantitative criterion that predicts the presence of a trap.

  6. Rail gun of thermonuclear pellet injection device

    International Nuclear Information System (INIS)

    Matsuda, Ryuichi; Kuribayashi, Shizuma; Oda, Yasutsugu.

    1993-01-01

    A rail gun of a thermonuclear pellet injection device using Lorentz force comprises rails constituted with materials of high melting point/low work function and a gas supply system for supplying low ionization/voltage gases into the rails to convert the gases into plasma armature. The low ionization voltage gases are converted into the plasma armature to decrease the resistance of the plasmas and suppress temperature elevation as Joule's heat and lower plasma temperature. Further, on the surface of the rails on the side of the cathode, since the rails are damaged by collision of positive ions due to voltage lowering, the rails on the side of the cathode are constituted with materials of low work function, as the countermeasure therefore, which facilitates emission of heat electrons from the surface of the cathode. With such procedures, thermal damages to the rail can be reduced. (N.H.)

  7. Fabrication and description of a cold cathode electron gun

    International Nuclear Information System (INIS)

    Sari, A.H.; Ghorannevis, M.; Hantehzadeh, M.R.; Yousefi, M.R.

    2003-01-01

    In this study the structure and schematic configuration of a cold cathode electron gun has been shown, which use obstructed discharge for electron producing. This type of discharge and mechanism of secondary electron emission by ions and fast neutral interaction have been described. The experiment starts in pressure of 1*10 -3 torr, in existence of helium gas. A negative DC voltage apply to a concave cathode up to -20 k V which determine electron energy

  8. A new method in predicting productivity of multi-stage fractured horizontal well in tight gas reservoirs

    Directory of Open Access Journals (Sweden)

    Yunsheng Wei

    2016-10-01

    Full Text Available The generally accomplished technique for horizontal wells in tight gas reservoirs is by multi-stage hydraulic fracturing, not to mention, the flow characteristics of a horizontal well with multiple transverse fractures are very intricate. Conventional methods, well as an evaluation unit, are difficult to accurately predict production capacity of each fracture and productivity differences between wells with a different number of fractures. Thus, a single fracture sets the minimum evaluation unit, matrix, fractures, and lateral wellbore model that are then combined integrally to approximate horizontal well with multiple transverse hydraulic fractures in tight gas reservoirs. This paper presents a new semi-analytical methodology for predicting the production capacity of a horizontal well with multiple transverse hydraulic fractures in tight gas reservoirs. Firstly, a mathematical flow model used as a medium, which is disturbed by finite conductivity vertical fractures and rectangular shaped boundaries, is established and explained by the Fourier integral transform. Then the idea of a single stage fracture analysis is incorporated to establish linear flow model within a single fracture with a variable rate. The Fredholm integral numerical solution is applicable for the fracture conductivity function. Finally, the pipe flow model along the lateral wellbore is adapted to couple multi-stages fracture mathematical models, and the equation group of predicting productivity of a multi-stage fractured horizontal well. The whole flow process from the matrix to bottom-hole and production interference between adjacent fractures is also established. Meanwhile, the corresponding iterative algorithm of the equations is given. In this case analysis, the productions of each well and fracture are calculated under the different bottom-hole flowing pressure, and this method also contributes to obtaining the distribution of pressure drop and production for every

  9. Youth, guns, and violent crime.

    Science.gov (United States)

    Blumstein, Alfred

    2002-01-01

    Young people are overrepresented as both victims and perpetrators of violence. Indeed, some commentators have suggested that recent cohorts of youth have been composed of "superpredators" who have little regard for human life. The evidence, however, suggests that other factors are responsible for recent increases in youth gun violence. This article analyzes the extent and causes of youth violence in the United States, paying particular attention to the late 1980s and early 1990s, when rates of homicide and robbery committed by youth rose to extremely high levels. Examination of trends for these crimes shows that: The increase in violence in the United States during the late 1980s and early 1990s was due primarily to an increase in violent acts committed by people under age 20. Similarly, dramatic declines in homicide and robbery in recent years are attributable primarily to a decline in youth violence. The increase in youth homicide was predominantly due to a significant increase in the use of handguns, which converted ordinary teenage fights and other violent encounters into homicides. Several other interrelated factors also fueled the rise in youth violence, including the rise of illegal drug markets, particularly for crack cocaine, the recruitment of youth into those markets, and an increase in gun carrying among young people. The author points out that youth violence diminished as the crack markets shrank, law enforcement increased efforts to control youth access to guns, youth gun carrying declined, and the robust economy provided legitimate jobs for young people.

  10. Flit-gun sprayer characteristics

    Directory of Open Access Journals (Sweden)

    J. R. Brown

    1998-05-01

    Full Text Available Six flit-gun sprayers were tested for possible use in mosquito adulticide programs where inexpensive nonmotorized application technology may be required. An analysis of variance for differences in droplets or = 48 µ, droplets/cm², volume median diameters, and mosquito mortality is provided. As shown by these data, good results can be achieved with this equipment.

  11. Electric rail gun application to space propulsion

    International Nuclear Information System (INIS)

    Barber, J.P.

    1979-01-01

    The paper examines the possibility of using the DC electric gun principles as a space vehicle propulsion system, capable of producing intermediate thrust levels. The application of an electromagnetic launch technique, called the DC electric rail gun, to the space propulsion concept of O'Neill, is examined. It is determined that the DC electric rail gun offers very high projectile accelerations and a very significant potential for reducing the size and mass of a reaction motor for space application. A detailed description of rail gun principles is given and some simple expressions for the accelerating force, gun impedance, power supply requirements, and system performance are discussed

  12. Developing of the large-bore powder gun for the Nevada test site

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Brian J [Los Alamos National Laboratory; Esparza, James S [Los Alamos National Laboratory

    2009-01-01

    Plate-impact experiments on single stage guns provide very planar loading conditions suitable for studying complex phenomena such as phase transitions and material strength, and provide important data useful for constraining and validating predictive models. The objective of the current work was to develop a large-bore (3.5-inches or greater) powder gun capable of accelerating projectiles to moderately high velocities (greater than 2.25 km/s) for impact experiments at Nevada Test Site. This gun will span a performance gap between existing gun facilities and provide a means of examining phenomena over a wide range of stresses and time-scales. Advantages of the large-bore gun include the capability to load multiple samples simultaneously, the use of large diameter samples that significantly extend the time duration of the experiment, and minimal tilt (no bow). This new capability required the development of a disposable confinement system that used an explosively driven closure method to prevent contamination from moving up into the gun system. Experimental results for both the gun system and the explosive valve are presented.

  13. Composition of pyrolysis gas from oil shale at various stages of heating

    Science.gov (United States)

    Martemyanov, S. M.; Bukharkin, A. A.; Koryashov, I. A.; Ivanov, A. A.

    2017-05-01

    Underground, the pyrolytic conversion of an oil shale in the nearest future may become an alternative source of a fuel gas and a synthetic oil. The main scientific problem in designing this technology is to provide a methodology for determination of the optimal mode of heating the subterranean formation. Such a methodology must allow predicting the composition of the pyrolysis products and the energy consumption at a given heating rate of the subterranean formation. The paper describes the results of heating of the oil shale fragments in conditions similar to the underground. The dynamics of composition of the gaseous products of pyrolysis are presented and analyzed.

  14. Granny, (don't) get your gun: competency issues in gun ownership by older adults.

    Science.gov (United States)

    Greene, Edith; Bornstein, Brian H; Dietrich, Hannah

    2007-01-01

    This article explores the possible risks associated with gun ownership by older adults. We summarize existing regulations on who may own firearms, especially with respect to age. We then present data on older gun owners and violence committed by older adults in general, followed by a discussion of gun violence perpetrated by gun owners whose functional and cognitive abilities have declined, perhaps as a result of dementia. For comparison purposes, we review regulations on driving among older adults, drawing parallels to gun ownership. The paper concludes with recommendations for ensuring the safety of older gun owners and others, balanced against citizens' right to bear arms, and with some directions for research.

  15. An optimal design of cluster spacing intervals for staged fracturing in horizontal shale gas wells based on the optimal SRVs

    Directory of Open Access Journals (Sweden)

    Lan Ren

    2017-09-01

    Full Text Available When horizontal well staged cluster fracturing is applied in shale gas reservoirs, the cluster spacing is essential to fracturing performance. If the cluster spacing is too small, the stimulated area between major fractures will be overlapped, and the efficiency of fracturing stimulation will be decreased. If the cluster spacing is too large, the area between major fractures cannot be stimulated completely and reservoir recovery extent will be adversely impacted. At present, cluster spacing design is mainly based on the static model with the potential reservoir stimulation area as the target, and there is no cluster spacing design method in accordance with the actual fracturing process and targets dynamic stimulated reservoir volume (SRV. In this paper, a dynamic SRV calculation model for cluster fracture propagation was established by analyzing the coupling mechanisms among fracture propagation, fracturing fluid loss and stress. Then, the cluster spacing was optimized to reach the target of the optimal SRVs. This model was applied for validation on site in the Jiaoshiba shale gasfield in the Fuling area of the Sichuan Basin. The key geological engineering parameters influencing the optimal cluster spacing intervals were analyzed. The reference charts for the optimal cluster spacing design were prepared based on the geological characteristics of south and north blocks in the Jiaoshiba shale gasfield. It is concluded that the cluster spacing optimal design method proposed in this paper is of great significance in overcoming the blindness in current cluster perforation design and guiding the optimal design of volume fracturing in shale gas reservoirs. Keywords: Shale gas, Horizontal well, Staged fracturing, Cluster spacing, Reservoir, Stimulated reservoir volume (SRV, Mathematical model, Optimal method, Sichuan basin, Jiaoshiba shale gasfield

  16. Early-stage aggregation in three-dimensional charged granular gas

    Science.gov (United States)

    Singh, Chamkor; Mazza, Marco G.

    2018-02-01

    Neutral grains made of the same dielectric material can attain considerable charges due to collisions and generate long-range interactions. We perform molecular dynamic simulations in three dimensions for a dilute, freely cooling granular gas of viscoelastic particles that exchange charges during collisions. As compared to the case of clustering of viscoelastic particles solely due to dissipation, we find that the electrostatic interactions due to collisional charging alter the characteristic size, morphology, and growth rate of the clusters. The average cluster size grows with time as a power law, whose exponent is relatively larger in the charged gas than the neutral case. The growth of the average cluster size is found to be independent of the ratio of characteristic Coulomb to kinetic energy, or equivalently, of the typical Bjerrum length. However, this ratio alters the crossover time of the growth. Both simulations and mean-field calculations based on Smoluchowski's equation suggest that a suppression of particle diffusion due to the electrostatic interactions helps in the aggregation process.

  17. New design of process for cold forging to improve multi-stage gas fitting

    Directory of Open Access Journals (Sweden)

    Han-Sung Huang

    2016-04-01

    Full Text Available This work develops a process that solves the problem of the formation of cracks inside forged gas fittings in the cold forging process that arises from poor forging process design. DEFORM-3D forming software was utilized, and macroscopic experiments with optical microscopy and scanning electron microscopy were conducted to investigate the processed structures and the distribution therein of metal flow lines, and to find the internal micro-cracks to determine whether the cold forging process is reasonable. Analytical results herein demonstrate that the stress and strain inside the gas fitting can be elucidated using metal forming software. Together with experimental results, they demonstrate that a concentration of stress damages the workpiece in the forming process. Moreover, as metal flow lines become narrower, the workpiece becomes more easily damaged. Consequently, the improved cold forging process that is described in this work should be utilized to reduce the occurrence of fine cracks and defects. Planning for proper die design and production, increasing the quality of products, and reducing the number of defective products promote industrial competitiveness.

  18. Gas exchange during exercise in different evolutional stages of chronic Chagas' heart disease

    Directory of Open Access Journals (Sweden)

    Fátima Palha de Oliveira

    2000-12-01

    Full Text Available OBJECTIVE: To compare gas exchange at rest and during exercise in patients with chronic Chagas' heart disease grouped according to the Los Andes clinical/hemodynamic classification. METHODS: We studied 15 healthy volunteers and 52 patients grouped according to the Los Andes clinical/hemodynamic classification as follows: 17 patients in group IA (normal electrocardiogram/echocardiogram, 9 patients in group IB (normal electrocardiogram and abnormal echocardiogram, 14 patients in group II (abnormal electrocardiogram/echocardiogram, without congestive heart failure, and 12 patients in group III (abnormal electrocardiogram/echocardiogram with congestive heart failure. The following variables were analyzed: oxygen consumption (V O2, carbon dioxide production (V CO2, gas exchange rate (R, inspiratory current volume (V IC, expiratory current volume (V EC, respiratory frequency, minute volume (V E, heart rate (HR, maximum load, O2 pulse, and ventilatory anaerobic threshold (AT. RESULTS: When compared with the healthy group, patients in groups II and III showed significant changes in the following variables: V O2peak, V CO2peak, V ICpeak, V ECpeak, E, HR, and maximum load. Group IA showed significantly better results for these same variables as compared with group III. CONCLUSION: The functional capacity of patients in the initial phase of chronic Chagas' heart disease is higher than that of patients in an advanced phase and shows a decrease that follows the loss in cardiac-hemodynamic performance.

  19. Gas exchange during exercise in different evolutional stages of chronic Chagas' heart disease.

    Science.gov (United States)

    Oliveira, F P; Pedrosa, R C; Giannella-Neto, A

    2000-12-01

    To compare gas exchange at rest and during exercise in patients with chronic Chagas' heart disease grouped according to the Los Andes clinical hemodynamic classification. We studied 15 healthy volunteers and 52 patients grouped according to the Los Andes clinical and hemodynamic classification as follows: 17 patients in group IA (normal electrocardiogram and echocardiogram), 9 patients in group IB (normal electrocardiogram and abnormal echocardiogram), 14 patients in group II (abnormal electrocardiogram and echocardiogram, without congestive heart failure), and 12 patients in group III (abnormal electrocardiogram and echocardiogram with congestive heart failure). The following variables were analyzed: oxygen consumption (V O2), carbon dioxide production (V CO2), gas exchange rate (R), inspiratory current volume (V IC), expiratory current volume (V EC), respiratory frequency, minute volume (V E), heart rate (HR), maximum load, O2 pulse, and ventilatory anaerobic threshold (AT). When compared with the healthy group, patients in groups II and III showed significant changes in the following variables: V O2 peak, V CO2 peak, V IC peak, V EC peak, E, HR, and maximum load. Group IA showed significantly better results for these same variables as compared with group III. The functional capacity of patients in the initial phase of chronic Chagas' heart disease is higher than that of patients in an advanced phase and shows a decrease that follows the loss in cardiac-hemodynamic performance.

  20. Use of Methanation for Optimization of a Hybrid Plant Combining Two-Stage Biomass Gasification, SOFCs and a Micro Gas Turbine

    DEFF Research Database (Denmark)

    Bang-Møller, Christian; Rokni, Masoud; Elmegaard, Brian

    2011-01-01

    A hybrid plant producing combined heat and power (CHP) from biomass by use of the two-stage gasification concept, solid oxide fuel cells (SOFCs) and a micro gas turbine (MGT) was considered for optimization. The hybrid plant is a sustainable and efficient alternative to conventional decentralized...... CHP plants. The demonstrated two-stage gasifier produces a clean product gas, thus ensuring the need for only simple gas conditioning prior to the SOFCs. Focus in this optimization study was on SOFC cooling and the investigation was conducted by system-level modelling combining zerodimensional...

  1. Design and experiment of high-current low-pressure plasma-cathode e-gun

    International Nuclear Information System (INIS)

    Xie Wenkai; Li Xiaoyun; Wang Bin; Meng Lin; Yan Yang; Gao Xinyan

    2006-01-01

    The preliminary design of a new high-power low pressure plasma-cathode e-gun is presented. Based on the hollow cathode effect and low-pressure glow discharge empirical formulas, the hollow cathode, the accelerating gap, and the working gas pressure region are given. The general experimental device of the low-pressure plasma cathode electron-gun generating high current density e-beam source is shown. Experiments has been done in continuous filled-in gases and gases-puff condition, and the discharging current of 150-200 A, the width of 60 μs and the collector current of 30-80 A, the width of 60 μs are obtained. The results show that the new plasma cathode e-gun can take the place of material cathode e-gun, especially in plasma filled microwave tubes. (authors)

  2. DC High Voltage Conditioning of Photoemission Guns at Jefferson Lab FEL

    International Nuclear Information System (INIS)

    DC high voltage photoemission electron guns with GaAs photocathodes have been used to produce polarized electron beams for nuclear physics experiments for about 3 decades with great success. In the late 1990s, Jefferson Lab adopted this gun technology for a free electron laser (FEL), but to assist with high bunch charge operation, considerably higher bias voltage is required compared to the photoguns used at the Jefferson Lab Continuous Electron Beam Accelerator Facility. The FEL gun has been conditioned above 400 kV several times, albeit encountering non-trivial challenges with ceramic insulators and field emission from electrodes. Recently, high voltage processing with krypton gas was employed to process very stubborn field emitters. This work presents a summary of the high voltage techniques used to high voltage condition the Jefferson Lab FEL photoemission gun.

  3. Solidification Mechanism of the D-Gun Sprayed Fe-Al Particles

    Directory of Open Access Journals (Sweden)

    Wołczyński W.

    2017-12-01

    Full Text Available The detonation gas spraying method is used to study solidification of the Fe-40Al particles after the D-gun spraying and settled on the water surface. The solidification is divided into two stages. First, the particle solid shell forms during the particle contact with the surrounding air / gas. Usually, the remaining liquid particle core is dispersed into many droplets of different diameter. A single Fe-Al particle is described as a body subjected to a rotation and finally to a centrifugal force leading to segregation of iron and aluminum. The mentioned liquid droplets are treated as some spheres rotated freely / chaotically inside the solid shell of the particle and also are subjected to the centrifugal force. The centrifugal force, and first of all, the impact of the particles onto the water surface promote a tendency for making punctures in the particles shell. The droplets try to desert / abandon the mother-particles through these punctures. Some experimental evidences for this phenomenon are delivered. It is concluded that the intensity of the mentioned phenomenon depends on a given droplet momentum. The droplets solidify rapidly during their settlement onto the water surface at the second stage of the process under consideration. A model for the solidification mechanism is delivered.

  4. Effects of Exposure to Gun Violence in Movies on Children's Interest in Real Guns.

    Science.gov (United States)

    Dillon, Kelly P; Bushman, Brad J

    2017-11-01

    More US children die by accidental gun use than children in other developed countries. One factor that can influence children's interest in guns is exposure to media containing guns. To test whether children who see a movie containing guns will handle a real gun longer and will pull the trigger more times than children who see the same movie not containing guns. One hundred four children aged 8 to 12 years recruited through advertisements were randomly assigned in pairs to watch a 20-minute PG-rated movie containing or not containing guns in a university laboratory. Children then played with toys and games in a room for 20 minutes while being video recorded. A cabinet in the room contained a real (disabled) gun with a sensor counting trigger pulls. Recordings were coded for the time spent holding the gun and in aggressive play. Data were collected from July 15, 2015, through January 1, 2016, and analyzed using generalized estimating equations (Tweedie log-link for time spent holding the gun; Poisson log-link for pulling the trigger). The 2 main outcomes were time spent holding the gun and the number of trigger pulls. Control variables included sex, age, trait aggressiveness, exposure to violent media, interest in guns, and number of guns at home. Among the 104 study participants (62 boys [59.6%] and 42 girls [40.4%]; mean (SD) age, 9.9 [1.5] years), the adjusted median number of trigger pulls among children who saw the movie containing guns was 2.8 (interquartile range [IQR], 0.2-2.8) compared with 0.01 (IQR, 0.01-0.2) among children who saw the movie not containing guns (adjusted odds ratio, 22.3; 95% CI, 6.0-83.4; P gun among children who saw a movie containing guns was 53.1 (IQR, 35.5-53.1) compared with 11.1 (IQR, 10.7-16.7) among children who saw the movie not containing guns (adjusted odds ratio, 3.0; 95% CI, 0.9-9.9; P = .07). Qualitative analyses on 4 pairs from each condition found that children who saw the movie containing guns also played more

  5. Brane Gas-Driven Bulk Expansion as a Precursor Stage to Brane Inflation

    International Nuclear Information System (INIS)

    Shuhmaher, Natalia; Brandenberger, Robert

    2006-01-01

    We propose a new way of obtaining slow-roll inflation in the context of higher dimensional models motivated by string and M theory. In our model, all extra spatial dimensions are orbifolded. The initial conditions are taken to be a hot dense bulk brane gas which drives an initial phase of isotropic bulk expansion. This phase ends when a weak potential between the orbifold fixed planes begins to dominate. For a wide class of potentials, a period during which the bulk dimensions decrease sufficiently slowly to lead to slow-roll inflation of the three dimensions parallel to the orbifold fixed planes will result. Once the separation between the orbifold fixed planes becomes of the string scale, a repulsive potential due to string effects takes over and leads to a stabilization of the radion modes. The conversion of bulk branes into radiation during the phase of bulk contraction leads to reheating

  6. Development And Characterization Of A Liner-On-Target Injector For Staged Z-Pinch Experiments

    Science.gov (United States)

    Valenzuela, J. C.; Conti, F.; Krasheninnikov, I.; Narkis, J.; Beg, F.; Wessel, F. J.; Rahman, H. U.

    2016-10-01

    We present the design and optimization of a liner-on-target injector for Staged Z-pinch experiments. The injector is composed of an annular high atomic number (e.g. Ar, Kr) gas-puff and an on-axis plasma gun that delivers the ionized deuterium target. The liner nozzle injector has been carefully studied using Computational Fluid Dynamics (CFD) simulations to produce a highly collimated 1 cm radius gas profile that satisfies the theoretical requirement for best performance on the 1 MA Zebra current driver. The CFD simulations produce density profiles as a function of the nozzle shape and gas. These profiles are initialized in the MHD MACH2 code to find the optimal liner density for a stable, uniform implosion. We use a simple Snowplow model to study the plasma sheath acceleration in a coaxial plasma gun to help us properly design the target injector. We have performed line-integrated density measurements using a CW He-Ne laser to characterize the liner gas and the plasma gun density as a function of time. The measurements are compared with models and calculations and benchmarked accordingly. Advanced Research Projects Agency - Energy, DE-AR0000569.

  7. Guns, Suicide, COPD and Sleep

    Directory of Open Access Journals (Sweden)

    Robbins RA

    2018-03-01

    Full Text Available No abstract available. Article truncated at 150 words. Within the past year two tragic events, the shootings in Las Vegas and Florida have renewed the debate about guns. The politics and the money that fuels the political debate have sharply divided politicians. As tragic as these mass shootings are, deaths by suicide far outnumber the loss of live in these shootings. In 2014 suicide was the tenth most common cause of death with 42,826 lives lost (1. Half of the suicides were by firearm (21,386. The medical profession has traditionally been reluctant to speak about politically sensitive issues such as abortion, sexuality, and guns. However, beginning early in this millennium some medical societies such as the American Academy of Pediatrics, the US Preventative Services Task Force and even the Department of Veterans Affairs were suggesting physicians ask patients about gun behavior, but a few patients complained (2-5. There were some anecdotal reports of patients feeling “pressured” to answer …

  8. X-Band RF Gun Development

    International Nuclear Information System (INIS)

    Vlieks, A.E.

    2012-01-01

    In support of the MEGa-ray program at LLNL and the High Gradient research program at SLAC, a new X-band multi-cell RF gun is being developed. This gun, similar to earlier guns developed at SLAC for Compton X-ray source program, will be a standing wave structure made of 5.5 cells operating in the pi mode with copper cathode. This gun was designed following criteria used to build SLAC X-band high gradient accelerating structures. It is anticipated that this gun will operate with surface electric fields on the cathode of 200 MeV/m with low breakdown rate. RF will be coupled into the structure through a final cell with symmetric duel feeds and with a shape optimized to minimize quadrupole field components. In addition, geometry changes to the original gun, operated with Compton X-ray source, will include a wider RF mode separation, reduced surface electric and magnetic fields.

  9. Joule-Thomson effect in a Pierce electron gun

    International Nuclear Information System (INIS)

    Batalin, V.A.

    1982-01-01

    A model which can be investigated both by means of the system of Vlasov equations and by means of ideal gas state equation is proposed for evaluation of emittance growth in the Pierce electron gun of electron beam with the limiting small distribution rate and intended for electron cooling facilities. The assumption has been made that transverse emittance growth is different from the zero. Thermodynamical approach to the problem of electron beam propagation permits to evaluate the increase of its emittance. It is shown that the increase of the electron beam emittance in the Pierce electron gun is similar to Joule-Thompson effect for gases. The effect increases with the decrease of the beam initial temperature. The increase of the emittance can become essential even in hte perfect (without aberration) Pierce optics at beam transverse temperature of the order of 0.1 eV

  10. LEAF GAS EXCHANGE CHARACTERISTICS OF FOUR PAPAYA GENOTYPES DURING DIFFERENT STAGES OF DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    CAMPOSTRINI ELIEMAR

    2001-01-01

    Full Text Available In this research, was used four papaya (Carica papaya L. genotypes: three from the 'Solo ( Sunrise Solo TJ, Sunrise Solo 72/12 and Baixinho de Santa Amália group and one from the 'Formosa' group (Know-You 01. They were grown in plastic pots containing a sandy-clay-loam soil subjected to pH correction and fertilization, under greenhouse conditions. Throughout the experimental period plants were subjected to periodic irrigation to maintain the soil humitidy around field capacity. The experiment was conducted 73 days after sowing. In all genotypes, leaf gas exchange characteristics were determined. The net photosynthetic rate (A, mumol m-2 s-1 , stomatal conductance (g s mol m-2 s-1, leaf temperature (T I, 0C and intercellular carbon dioxide concentration (ci, muL L-1 on the 4th, 5th, 6th, 7th, 8th and 9th leaves from the plant apex were determined. No significant differences were observed for A, g s, c i, or Tl either among the leaves sampled from any of the genotypes. A was positively correlated with g s and in the other hand T I and g s were negatively correlated. The results suggest that, for 73 DAP, all the sampled papaya leaves functioned as sources of organs.

  11. Racism, gun ownership and gun control: biased attitudes in US whites may influence policy decisions.

    Directory of Open Access Journals (Sweden)

    Kerry O'Brien

    Full Text Available OBJECTIVE: Racism is related to policies preferences and behaviors that adversely affect blacks and appear related to a fear of blacks (e.g., increased policing, death penalty. This study examined whether racism is also related to gun ownership and opposition to gun controls in US whites. METHOD: The most recent data from the American National Election Study, a large representative US sample, was used to test relationships between racism, gun ownership, and opposition to gun control in US whites. Explanatory variables known to be related to gun ownership and gun control opposition (i.e., age, gender, education, income, conservatism, anti-government sentiment, southern vs. other states, political identification were entered in logistic regression models, along with measures of racism, and the stereotype of blacks as violent. Outcome variables included; having a gun in the home, opposition to bans on handguns in the home, support for permits to carry concealed handguns. RESULTS: After accounting for all explanatory variables, logistic regressions found that for each 1 point increase in symbolic racism there was a 50% increase in the odds of having a gun at home. After also accounting for having a gun in the home, there was still a 28% increase in support for permits to carry concealed handguns, for each one point increase in symbolic racism. The relationship between symbolic racism and opposition to banning handguns in the home (OR1.27 CI 1.03,1.58 was reduced to non-significant after accounting for having a gun in the home (OR1.17 CI.94,1.46, which likely represents self-interest in retaining property (guns. CONCLUSIONS: Symbolic racism was related to having a gun in the home and opposition to gun control policies in US whites. The findings help explain US whites' paradoxical attitudes towards gun ownership and gun control. Such attitudes may adversely influence US gun control policy debates and decisions.

  12. Racism, Gun Ownership and Gun Control: Biased Attitudes in US Whites May Influence Policy Decisions

    OpenAIRE

    O?Brien, Kerry; Forrest, Walter; Lynott, Dermot; Daly, Michael

    2013-01-01

    OBJECTIVE: Racism is related to policies preferences and behaviors that adversely affect blacks and appear related to a fear of blacks (e.g., increased policing, death penalty). This study examined whether racism is also related to gun ownership and opposition to gun controls in US whites. METHOD: The most recent data from the American National Election Study, a large representative US sample, was used to test relationships between racism, gun ownership, and opposition to gun control in US wh...

  13. Guns, Crime, and Academics: Some Reflections on the Gun Control Debate.

    OpenAIRE

    Parker, Jeffrey S

    2001-01-01

    This comment on Thomas Marvell's "The Impact of Banning Juvenile Gun Possession" analyzes Marvell's empirical findings and their policy implications for gun control legislation. While Marvell's article stresses the absence of any finding favorable to juvenile gun bans, this comment points out that the statistical results actually support the stronger finding that some of the juvenile gun bans are associated with a statistically significant increase in homicides nationwide. Under either findin...

  14. Racism, Gun Ownership and Gun Control: Biased Attitudes in US Whites May Influence Policy Decisions

    Science.gov (United States)

    O’Brien, Kerry; Forrest, Walter; Lynott, Dermot; Daly, Michael

    2013-01-01

    Objective Racism is related to policies preferences and behaviors that adversely affect blacks and appear related to a fear of blacks (e.g., increased policing, death penalty). This study examined whether racism is also related to gun ownership and opposition to gun controls in US whites. Method The most recent data from the American National Election Study, a large representative US sample, was used to test relationships between racism, gun ownership, and opposition to gun control in US whites. Explanatory variables known to be related to gun ownership and gun control opposition (i.e., age, gender, education, income, conservatism, anti-government sentiment, southern vs. other states, political identification) were entered in logistic regression models, along with measures of racism, and the stereotype of blacks as violent. Outcome variables included; having a gun in the home, opposition to bans on handguns in the home, support for permits to carry concealed handguns. Results After accounting for all explanatory variables, logistic regressions found that for each 1 point increase in symbolic racism there was a 50% increase in the odds of having a gun at home. After also accounting for having a gun in the home, there was still a 28% increase in support for permits to carry concealed handguns, for each one point increase in symbolic racism. The relationship between symbolic racism and opposition to banning handguns in the home (OR1.27 CI 1.03,1.58) was reduced to non-significant after accounting for having a gun in the home (OR1.17 CI.94,1.46), which likely represents self-interest in retaining property (guns). Conclusions Symbolic racism was related to having a gun in the home and opposition to gun control policies in US whites. The findings help explain US whites’ paradoxical attitudes towards gun ownership and gun control. Such attitudes may adversely influence US gun control policy debates and decisions. PMID:24204867

  15. Racism, gun ownership and gun control: biased attitudes in US whites may influence policy decisions.

    Science.gov (United States)

    O'Brien, Kerry; Forrest, Walter; Lynott, Dermot; Daly, Michael

    2013-01-01

    Racism is related to policies preferences and behaviors that adversely affect blacks and appear related to a fear of blacks (e.g., increased policing, death penalty). This study examined whether racism is also related to gun ownership and opposition to gun controls in US whites. The most recent data from the American National Election Study, a large representative US sample, was used to test relationships between racism, gun ownership, and opposition to gun control in US whites. Explanatory variables known to be related to gun ownership and gun control opposition (i.e., age, gender, education, income, conservatism, anti-government sentiment, southern vs. other states, political identification) were entered in logistic regression models, along with measures of racism, and the stereotype of blacks as violent. Outcome variables included; having a gun in the home, opposition to bans on handguns in the home, support for permits to carry concealed handguns. After accounting for all explanatory variables, logistic regressions found that for each 1 point increase in symbolic racism there was a 50% increase in the odds of having a gun at home. After also accounting for having a gun in the home, there was still a 28% increase in support for permits to carry concealed handguns, for each one point increase in symbolic racism. The relationship between symbolic racism and opposition to banning handguns in the home (OR1.27 CI 1.03,1.58) was reduced to non-significant after accounting for having a gun in the home (OR1.17 CI.94,1.46), which likely represents self-interest in retaining property (guns). Symbolic racism was related to having a gun in the home and opposition to gun control policies in US whites. The findings help explain US whites' paradoxical attitudes towards gun ownership and gun control. Such attitudes may adversely influence US gun control policy debates and decisions.

  16. Rate control for electron gun evaporation

    International Nuclear Information System (INIS)

    Schellingerhout, A.J.G.; Janocko, M.A.; Klapwijk, T.M.; Mooij, J.E.

    1989-01-01

    Principles for obtaining high-quality rate control for electron gun evaporation are discussed. The design criteria for rate controllers are derived from this analysis. Results are presented which have been obtained with e-guns whose evaporation rate is controlled by a Wehnelt electrode or by sweeping of the electron beam. Further improvements of rate stability can be obtained by improved design of e-guns and power supplies

  17. Improved Orifice Plate for Spray Gun

    Science.gov (United States)

    Cunningham, W.

    1986-01-01

    Erratic spray pattern of commercial spray gun changed to repeatable one by simple redesign of two parts. In modified spray gun orifice plate and polytetrafluoroethylene bushing redesigned to assure centering and alignment with nozzle. Such improvement useful in many industrial applications requiring repeatable spray patterns. Might include spraying of foam insulation, paint, other protective coatings, detergents, abrasives, adhesives, process chemicals, or fuels. Unmodified spray gun produces erratic spray because lateral misalignment between orifice plate and nozzle.

  18. RF gun using laser-triggered photocathode

    International Nuclear Information System (INIS)

    Akiyama, H.; Otake, Y.; Naito, T.; Takeuchi, Y.; Yoshioka, M.

    1992-01-01

    An RF gun using laser-triggered photocathode has many advantages as an injector of the linear colliders since it can generate a low emittance and high current pulsed beam. The experimental facility for the RF gun, such as an RF system, a laser system and a photocathode have been fabricated to study the fundamental characteristics. The dynamics of the RF gun has also studied by the 1D sheet beam model. (author)

  19. Gun Control in Australia: A Criminological Perspective

    Directory of Open Access Journals (Sweden)

    Rick Sarre

    2015-11-01

    Full Text Available In recent months there has been an upsurge in contributions to the popular press from social commentators insisting that guns make our nation safer. This essay questions these assertions. The paper provides evidence to support a contrary affirmation: that is, in order to have a reduction in gun violence, there needs to be a reduction in the number of guns generally, and a continuation of the legal controls that currently shape firearms policy in Australia.

  20. An inexact two-stage stochastic energy systems planning model for managing greenhouse gas emission at a municipal level

    International Nuclear Information System (INIS)

    Energy management systems are highly complicated with greenhouse-gas emission reduction issues and a variety of social, economic, political, environmental and technical factors. To address such complexities, municipal energy systems planning models are desired as they can take account of these factors and their interactions within municipal energy management systems. This research is to develop an interval-parameter two-stage stochastic municipal energy systems planning model (ITS-MEM) for supporting decisions of energy systems planning and GHG (greenhouse gases) emission management at a municipal level. ITS-MEM is then applied to a case study. The results indicated that the developed model was capable of supporting municipal energy systems planning and environmental management under uncertainty. Solutions of ITS-MEM would provide an effective linkage between the pre-regulated environmental policies (GHG-emission reduction targets) and the associated economic implications (GHG-emission credit trading).

  1. Conceptual Design for CLIC Gun Pulser

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Tao [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2016-01-08

    The Compact Linear Collider (CLIC) is a proposed future electron-positron collider, designed to perform collisions at energies from 0.5 to 5 TeV, with a nominal design optimized for 3 TeV (Dannheim, 2012). The Drive Beam Accelerator consists of a thermionic DC gun, bunching section and an accelerating section. The thermionic gun needs deliver a long (~143us) pulse of current into the buncher. A pulser is needed to drive grid of the gun to generate a stable current output. This report explores the requirements of the gun pulser and potential solutions to regulate grid current.

  2. Ion tracking in photocathode rf guns

    Directory of Open Access Journals (Sweden)

    John W. Lewellen

    2002-02-01

    Full Text Available Projected next-generation linac-based light sources, such as PERL or the TESLA free-electron laser, generally assume, as essential components of their injector complexes, long-pulse photocathode rf electron guns. These guns, due to their design rf pulse durations of many milliseconds to continuous wave, may be more susceptible to ion bombardment damage of their cathodes than conventional rf guns, which typically use rf pulses of microsecond duration. This paper explores this possibility in terms of ion propagation within the gun, and presents a basis for future study of the subject.

  3. Operation of the APS rf gun

    International Nuclear Information System (INIS)

    Lewellen, J. W.

    1998-01-01

    The Advanced Photon Source (APS) has a thermionic-cathode rf gun system capable of providing beam to the APS linac. The gun system consists of a 1.6-cell thermionic-cathode rf gun, a fast kicker for beam current control, and an alpha magnet for bunch compression and injection into the APS linac line. This system is intended for use both as an injector for positron creation, and as a first beam source for the Low-Energy Undulator Test Line (LEUTL) project [1]. The first measured performance characteristics of the gun are presented.

  4. Health and Gun Violence. Guns as a Public-Health Issue.

    Science.gov (United States)

    Duran, Victoria

    1994-01-01

    Violence in all settings has reached epidemic proportions. Most shootings are committed by friends or relatives following an argument or when playing with guns. The public needs education about nonviolent ways of coping with anger and about the high cost of gun violence. Suggestions for avoiding gun violence and the PTA position on firearms are…

  5. Gun shows across a multistate American gun market: observational evidence of the effects of regulatory policies.

    Science.gov (United States)

    Wintemute, Garen J

    2007-06-01

    To describe gun shows and assess the impact of increased regulation on characteristics linked to their importance as sources of guns used in crime. Cross-sectional, observational. Data were collected at a structured sample of 28 gun shows in California, which regulates these events and prohibits undocumented private party gun sales; and in Arizona, Nevada, Texas and Florida-all leading sources of California's crime guns--where these restrictions do not exist. Size of shows, measured by numbers of gun vendors and people in attendance; number and nature of guns for sale by gun vendors; measures of private party gun sales and illegal surrogate ("straw") gun purchases. Shows in comparison states were larger, but the number of attendees per gun vendor was higher in California. None of these differences was statistically significant. Armed attendees were more common in other states (median 5.7%, interquartile range (IQR) 3.9-10.0%) than in California (median 1.1%, IQR 0.5-2.2%), p = 0.0007. Thirty percent of gun vendors both in California and elsewhere were identifiable as licensed firearm retailers. There were few differences in the types or numbers of guns offered for sale; vendors elsewhere were more likely to sell assault weapons (34.9% and 13.3%, respectively; p = 0.001). Straw purchases were more common in the comparison states (rate ratio 6.6 (95% CI 0.9 to 49.1), p = 0.06). California's regulatory policies were associated with a decreased incidence of anonymous, undocumented gun sales and illegal straw purchases at gun shows. No significant adverse effects of these policies were observed.

  6. From gun politics to self-defense politics: a feminist critique of the great gun debate.

    Science.gov (United States)

    Carlson, Jennifer D

    2014-03-01

    This article calls attention to a problematic binary produced by public debates surrounding gun rights and gun control-namely, that women must choose armed self-protection or no self-protection at all. I argue that both anti- and pro-gun discourses, drawing on and reproducing race and class privileges, use assumptions about women's physical inferiority to further their agendas. I highlight how both sides have used guns as the proxy for self-defense and conclude by calling for a shift in public discourse to focus on the broader question of the right to self-defense rather than the narrower question of gun rights.

  7. Clinging to their Guns? The New Politics of Gun Carry in Everyday Life

    OpenAIRE

    Carlson, Jennifer

    2013-01-01

    Alongside a series of high-profile massacres over the past decade, Americans continue to turn to guns as the solution to, rather than the cause of, violent crime. Since the 1970s, most US states have significantly loosened restrictions on gun carrying for self-defense, and today, over 8 million Americans hold permits to carry guns concealed. Contrary to popular images of gun culture, this is not a white-only affair: in Michigan, whites and African Americans are licensed to carry guns at rough...

  8. Effect of charge exchange on ion guns and an application to inertial- electrostatic confinement devices

    International Nuclear Information System (INIS)

    Baxter, D.C.; Stuart, G.W.

    1982-01-01

    In 1967, R. L. Hirsch [J. Appl. Phys. 38, 4522 (1967)] reported neutron production rates of 10 10 neutrons per second from an electrostatic inertial confinement device. The device consisted of six ion guns injecting deuterium or a mixture of deuterium and tritium ions into an evacuated cathode chamber at 30--150 keV. No previous theoretical model for this experiment has adequately explained the observed neutron fluxes. A new model that includes the effects of charge exchange and ionization in the ion guns is analyzed. This model predicts three main features of the observed neutron flux: Neutron output proportional to gun current, neutron production localized at the center of the evacuated chamber, and neutron production decreasing with increasing neutral background gas density. Previous analysis modelled the ion guns as being monoenergetic. In this study, the ion gun output is modelled as a mixture of ions and fast neutrals with energies ranging from zero to the maximum gun energy. Using this theoretical model, a survey of the possible operating parameters indicates that the device was probably operated at or near the most efficient combined values of voltage and background pressure. Applications of the theory to other devices are discussed

  9. Coaxial Plasma Gun Development for the ARPA-E PLX- α Project

    Science.gov (United States)

    Witherspoon, F. Douglas; Case, Andrew; Brockington, Samuel

    2015-11-01

    We describe the renewed effort to design and build coaxial plasma guns appropriate for a scaling study of spherically imploding plasma liners as a standoff magneto-inertial-fusion driver under the ARPA-E Accelerating Low-Cost Plasma Heating And Assembly (ALPHA) program. HyperV joins LANL, UAH, UNM, BNL, and Tech-X to develop, build, operate and analyze a 60 plasma gun experiment using the existing PLX facility at LANL. The guns will be designed to operate over a scaling range of operating parameters: 0.5-5.0 mg of Ar, Ne, N2, Kr, and Xe; 20-60 km/s; 1016 -1017 cm-3 muzzle density; and up to 7.5 kJ stored energy per gun. Each gun is planned to incorporate contoured gaps, fast dense gas injection and triggering, and innovative integral sparkgap switching and pfn configurations to reduce inductance, cost, and complexity, and to increase efficiency and system reliability. We will describe the overall design approach for the guns and pulsed power systems. This work supported by the ARPA-E ALPHA Program.

  10. The Xygra gun simulation tool.

    Energy Technology Data Exchange (ETDEWEB)

    Garasi, Christopher Joseph; Lamppa, Derek C.; Aubuchon, Matthew S.; Shirley, David Noyes; Robinson, Allen Conrad; Russo, Thomas V.

    2008-12-01

    Inductive electromagnetic launchers, or coilguns, use discrete solenoidal coils to accelerate a coaxial conductive armature. To date, Sandia has been using an internally developed code, SLINGSHOT, as a point-mass lumped circuit element simulation tool for modeling coilgun behavior for design and verification purposes. This code has shortcomings in terms of accurately modeling gun performance under stressful electromagnetic propulsion environments. To correct for these limitations, it was decided to attempt to closely couple two Sandia simulation codes, Xyce and ALEGRA, to develop a more rigorous simulation capability for demanding launch applications. This report summarizes the modifications made to each respective code and the path forward to completing interfacing between them.

  11. The Effects of Cueing and Framing on Youth Attitudes towards Gun Control and Gun Rights

    Directory of Open Access Journals (Sweden)

    Stephen Wu

    2018-02-01

    Full Text Available I analyze attitudes towards gun control from a recent survey of American high school students. For students who most closely identify as Republicans, cueing them to think about prior school shootings increases their agreement that armed staff in schools will improve safety and arming citizens will reduce risk of mass shootings. For those identifying as Democrats and Independents, providing them with selective information that certain states have loose gun control laws and low rates of gun violence makes them more supportive of gun rights. For Republicans, providing selective information that certain states have loose gun control laws and high rates of gun violence makes them less supportive of gun rights. These results suggest that emotional cues may exacerbate a priori biases, while informational cues may be more likely to change people’s minds about firearm policies.

  12. Action alters object identification: wielding a gun increases the bias to see guns.

    Science.gov (United States)

    Witt, Jessica K; Brockmole, James R

    2012-10-01

    Stereotypes, expectations, and emotions influence an observer's ability to detect and categorize objects as guns. In light of recent work in action-perception interactions, however, there is another unexplored factor that may be critical: The action choices available to the perceiver. In five experiments, participants determined whether another person was holding a gun or a neutral object. Critically, the participant did this while holding and responding with either a gun or a neutral object. Responding with a gun biased observers to report "gun present" more than did responding with a ball. Thus, by virtue of affording a perceiver the opportunity to use a gun, he or she was more likely to classify objects in a scene as a gun and, as a result, to engage in threat-induced behavior (raising a firearm to shoot). In addition to theoretical implications for event perception and object identification, these findings have practical implications for law enforcement and public safety.

  13. Where have all the gun deaths gone?

    African Journals Online (AJOL)

    Gun violence denialists recently dismissed the findings of two studies presented at a seminar co-hosted by Gun Free South Africa, the. Institute for Security Studies and the African. Policing Civilian Oversight Forum. Abrahams et al.[1] compared the profile of female homicides from two representative national samples.

  14. Fighting Juvenile Gun Violence. Juvenile Justice Bulletin.

    Science.gov (United States)

    Sheppard, David; Grant, Heath; Rowe, Wendy; Jacobs, Nancy

    This bulletin describes the Office of Juvenile Justice and Delinquency Prevention's efforts to fight juvenile gun violence. The Office awarded four community demonstration grants to implement "Partnerships To Reduce Juvenile Gun Violence." Partnership goals include increasing the effectiveness of existing strategies by enhancing and…

  15. Gun Control: The Debate and Public Policy.

    Science.gov (United States)

    Watkins, Christine

    1997-01-01

    Provides an overview and background information on the debate over gun control, as well as several teaching ideas. Handouts include a list of related topics drawn from various disciplines (economics, U.S. history), seven arguments for and against gun control, and a set of policy evaluation guidelines. (MJP)

  16. Cerebral damage caused by nail gun injury

    DEFF Research Database (Denmark)

    Andersen, Chris

    2016-01-01

    Background Accidents with nail guns are rather common, especially in the construction industry. Most injuries involve the extremities and several present with intracerebral injuries. When the patient is unconscious, it can be a big challenge to determine whether the injury is an accident, self....... The forensic examination showed lesions of intracranial surgery and minor bruises on the arms. No sign of defense injuries was found. There were no signs of malfunction of the nail gun-wielding robot. On the side of the machine, there were a handheld nail gun and the police investigated the case as a possible...... criminal act. They found bloodstains on the back of the machine. When awake, the man explained, that by accident, he had hit his head against a nail gun and as a result of this, the nail gun delivered a nail into his skull. Conclusion Sometimes, the circumstances of a case are not clear...

  17. Interpreting the empirical evidence on illegal gun market dynamics.

    Science.gov (United States)

    Braga, Anthony A; Wintemute, Garen J; Pierce, Glenn L; Cook, Philip J; Ridgeway, Greg

    2012-10-01

    Thousands of Americans are killed by gunfire each year, and hundreds of thousands more are injured or threatened with guns in robberies and assaults. The burden of gun violence in urban areas is particularly high. Critics suggest that the results of firearm trace data and gun trafficking investigation studies cannot be used to understand the illegal supply of guns to criminals and, therefore, that regulatory and enforcement efforts designed to disrupt illegal firearms markets are futile in addressing criminal access to firearms. In this paper, we present new data to address three key arguments used by skeptics to undermine research on illegal gun market dynamics. We find that criminals rely upon a diverse set of illegal diversion pathways to acquire guns, gun traffickers usually divert small numbers of guns, newer guns are diverted through close-to-retail diversions from legal firearms commerce, and that a diverse set of gun trafficking indicators are needed to identify and shut down gun trafficking pathways.

  18. Gun Violence, Mental Illness, And Laws That Prohibit Gun Possession: Evidence From Two Florida Counties.

    Science.gov (United States)

    Swanson, Jeffrey W; Easter, Michele M; Robertson, Allison G; Swartz, Marvin S; Alanis-Hirsch, Kelly; Moseley, Daniel; Dion, Charles; Petrila, John

    2016-06-01

    Gun violence kills about ninety people every day in the United States, a toll measured in wasted and ruined lives and with an annual economic price tag exceeding $200 billion. Some policy makers suggest that reforming mental health care systems and improving point-of-purchase background checks to keep guns from mentally disturbed people will address the problem. Epidemiological research shows that serious mental illness contributes little to the risk of interpersonal violence but is a strong factor in suicide, which accounts for most firearm fatalities. Meanwhile, the effectiveness of gun restrictions focused on mental illness remains poorly understood. This article examines gun-related suicide and violent crime in people with serious mental illnesses, and whether legal restrictions on firearm sales to people with a history of mental health adjudication are effective in preventing gun violence. Among the study population in two large Florida counties, we found that 62 percent of violent gun crime arrests and 28 percent of gun suicides involved individuals not legally permitted to have a gun at the time. Suggested policy reforms include enacting risk-based gun removal laws and prohibiting guns from people involuntarily detained in short-term psychiatric hospitalizations. Project HOPE—The People-to-People Health Foundation, Inc.

  19. Gun Violence Following Inpatient Psychiatric Treatment: Offense Characteristics, Sources of Guns, and Number of Victims.

    Science.gov (United States)

    Kivisto, Aaron J

    2017-10-01

    This study presents data on the relative contribution to gun violence by people with a history of inpatient psychiatric treatment and on federal efforts to deter presumptively dangerous persons from obtaining firearms, information useful for analyzing the potential public health benefits of gun policies targeting people with serious mental illness. The study also estimates the reduction in gun violence victims that would be expected if individuals with a previous psychiatric hospitalization were prohibited from purchasing firearms. Data from 838 violent gun offenders from a nationally representative sample of state prison inmates were analyzed. Those with and without a history of psychiatric hospitalization were compared on a range of offense characteristics, including relationship to the victim, number of victims, location of the offense, and source of firearms. Inmates with a history of hospitalization constituted 12% of all violent gun offenders and accounted for 13% of the sample's victims. They were less likely than those without a previous hospitalization to victimize strangers (odds ratio=.52) and were no more likely to commit gun violence in public or to have multiple victims. Among those with previous hospitalizations, 78% obtained guns from sources not subject to federal background checks. Of the total 1,041 victims of gun violence, only 3% were victimized by participants with a history of hospitalization who obtained guns from currently regulated sources. Prohibiting all individuals with a history of psychiatric hospitalization from purchasing firearms, absent expanded background checks, was estimated to reduce the number of gun violence victims by only 3%.

  20. Gun Violence, Mental Illness, And Laws That Prohibit Gun Possession: Evidence From Two Florida Counties

    Science.gov (United States)

    Swanson, Jeffrey W.; Easter, Michele M.; Robertson, Allison G.; Swartz, Marvin S.; Alanis-Hirsch, Kelly; Moseley, Daniel; Dion, Charles; Petrila, John

    2016-01-01

    Gun violence kills about ninety people every day in the United States, a toll measured in wasted and ruined lives and with an annual economic price tag exceeding $200 billion. Some policy makers suggest that reforming mental health care systems and improving point-of-purchase background checks to keep guns from mentally disturbed people will address the problem. Epidemiological research shows that serious mental illness contributes little to the risk of interpersonal violence but is a strong factor in suicide, which accounts for most firearm fatalities. Meanwhile, the effectiveness of gun restrictions focused on mental illness remains poorly understood. This article examines gun-related suicide and violent crime in people with serious mental illnesses, and whether legal restrictions on firearm sales to people with a history of mental health adjudication are effective in preventing gun violence. Among the study population in two large Florida counties, we found that 62 percent of violent gun crime arrests and 28 percent of gun suicides involved individuals not legally permitted to have a gun at the time. Suggested policy reforms include enacting risk-based gun removal laws and prohibiting guns from people involuntarily detained in short-term psychiatric hospitalizations. PMID:27269024

  1. The supply and demand for guns to juveniles: Oakland's gun tracing project.

    Science.gov (United States)

    Calhoun, Deane; Dodge, Andrea Craig; Journel, Coraline S; Zahnd, Elaine

    2005-12-01

    In response to Oakland, California's high level of gun violence affecting young people, the East Oakland Partnership to Reduce Juvenile Gun Violence, a citywide collaboration, was formed in 1997. In 1999, the Partnership established the Oakland Gun Tracing Project to develop evidence-based policy recommendations aimed at reducing the supply of and demand for gun acquisition among urban youth. The advocacy project involved gathering, analyzing, and using police record and gun sale/registration data to inform policy and practice. Such data were collected for all gun crimes committed in Oakland, California between 1998 and 1999 in which a juvenile was either the suspect or the victim. The 213 cases involved 263 juveniles of which 170 were suspects/perpetrators and 93 were victims. Suspects as well as victims were predominantly male and African American. The 213 cases involved 132 recovered guns. Only 55% of the cases were traced to a federally licensed dealer. Three-quarters of the guns were purchased near Oakland, California. Successful traces, defined as the ability to identify federally licensed dealers and initial purchasers, were completed on only 52 of the 132 guns, demonstrating systemic tracing difficulties. Data gathered for the project was used to advocate for numerous policy changes. Recommended policy strategies include initiating a comprehensive gun tracing program so police can track all secondary sales, new laws requiring federal handgun registration which would track ownership changes, required reporting of stolen firearms, and providing effective intervention services to all juveniles the first time they enter the criminal justice system.

  2. Use of a seismic air gun to reduce survival of nonnative lake trout embryos: A tool for conservation?

    Science.gov (United States)

    Cox, B.S.; Dux, A.M.; Quist, M.C.; Guy, C.S.

    2012-01-01

    The detrimental impacts of nonnative lake trout Salvelinus namaycush in the western USA have prompted natural resource management agencies in several states to implement lake trout suppression programs. Currently, these programs rely on mechanical removal methods (i.e., gill nets, trap nets, and angling) to capture subadult and adult lake trout. We conducted a study to explore the potential for using high-intensity sound from a relatively small (655.5 cm3 [40 in3]) seismic air gun to reduce survival of lake trout embryos. Lake trout embryos at multiple stages of development were exposed to a single discharge of the seismic air gun at two depths (5 and 15 m) and at two distances from the air gun (0.1 and 2.7 m). Control groups for each developmental stage, distance, and depth were treated identically except that the air gun was not discharged. Mortality in lake trout embryos treated at 0.1 m from the air gun was 100% at 74 daily temperature units in degrees Celsius (TU°C) at both depths. Median mortality in lake trout embryos treated at 0.1 m from the air gun at 207 TU°C (93%) and 267 °C (78%) appeared to be higher than that of controls (49% and 48%, respectively) at 15-m depth. Among the four lake trout developmental stages, exposure to the air gun at 0.1 m resulted in acute mortality up to 60% greater than that of controls. Mortality at a distance of 2.7 m did not appear to differ from that of controls at any developmental stage or at either depth. Our results indicate that seismic air guns have potential as an alternative tool for controlling nonnative lake trout, but further investigation is warranted.

  3. Dual-Stage Consumable-Free Thermal Modulator for the Hyphenation of Thermal Analysis, Gas Chromatography, and Mass Spectrometry.

    Science.gov (United States)

    Wohlfahrt, Sebastian; Fischer, Michael; Varga, Janos; Saraji-Bozorgzad, Mohammad-Reza; Matuschek, Georg; Denner, Thomas; Zimmermann, Ralf

    2016-01-05

    The design of the so-called "Peltier modulator" is presented. It is a new dual-stage consumable-free thermal modulator for thermal analysis-gas chromatography-mass spectrometry (TA-GC-MS). It requires only electrical power for operation as it facilitates thermo-electric coolers instead of cryogenics for trapping and resistive on-column heating for reinjection. Trapping and desorption temperatures as well as modulation cycles are freely adjustable. The stationary phase for the trapping region can be selected to suit the specific application, since common fused silica capillary is used. The Peltier modulator's performance is demonstrated with a broad range of different standard substances and with heavy crude oil as a complex real life sample. Successful modulation from n-pentane to pyrene (boiling points = 36/394 °C) is presented. The produced peaks show the narrowest bandwidths ever reported for a consumable-free thermal modulator, i.e., 12.8 ± 1.2 ms for n-pentadecane. The Peltier modulator is rugged, cost-effective, requires low maintenance, and decreases security issues significantly, compared to commercial available solutions using liquid N2/CO2.

  4. A fast-acting hydrogen gas source for staged pneumatic high-speed acceleration of fusion plasma fuel pellets

    International Nuclear Information System (INIS)

    Andersen, S.A.; Baekmark, L.

    1990-02-01

    This report describes a possible design of a fast, high-temperature, arc-driven hydrogen gas source module, to be used in a scheme for multistage high-speed pneumatic acceleration of fusion plasma fuel pellets. The potential of this scheme for operating with a moderate driving pressure at long acceleration path lengths is particular attractive for accelerating fragile hydrogen isotope ice pellets. From experiments with an ethanol-based arc unit, design parameters for a propeller module were assessed, and with a barrel-mounted ethanol module staged pneumatic acceleration of a plastic dummy pellet was demonstrated. In experiments with a hydrogenbased, cryogenic arc unit in which 200 joules of electrical energy were dissipated with a power level approaching 5 MW within 30 mus, the velocity of a 23-mg plastic pellet was increased from 1.7 to 2.4 km/s. Results in terms of barrel pressure transients and arc characteristics are described. (author) 20 ills., 8 refs

  5. The Tracing of VOC Composition of Acacia Honey During Ripening Stages by Comprehensive Two-Dimensional Gas Chromatography.

    Science.gov (United States)

    Vyviurska, Olga; Chlebo, Róbert; Pysarevska, Solomiya; Špánik, Ivan

    2016-10-01

    In this study, VOC profiles of acacia flowers and honey samples at different processing stages and related comb wax samples were studied using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry. It was found that some monoterpene compounds like α-pinene, myrcene, cis-β-ocimene, and 4-terpineol were common for acacia flower and all acacia honey samples, and the presence of verbenone and ocimene was first established in acacia honey. The most enriched VOC profile was obtained for raw honey before cell capping, where the final composition of lactones was achieved. On the contrary, number of alcohols, esters, and variety of terpenes, as well as their concentration in the honey samples decrease through ripening processes. Strained honey was characterized by the absence of camphor, α-bisabolol, and 3-carene, while isophorone and hexanoic acid were identified only in this type of honey. The composition of final VOC profile of honey was also influenced by the age of comb wax. The additional aromatic and lactone compounds, e.g., phenol, 1-phenylethanol, δ-hexalactone, and γ-heptalactone were observed for honey maturated in old dark comb wax. © 2016 Wiley-VHCA AG, Zürich.

  6. Gun Violence, mental health, and Connecticut physicians.

    Science.gov (United States)

    Dodds, Peter R; Anderson, Caitlyn O; Dodds, Jon H

    2014-01-01

    While there is a public perception that gun violence is associated with mental illness we present evidence that it is a complex public health problem which defies simple characterizations and solutions. Only a small percentage of individuals with mental illness are at risk for extreme violence and they account for only a small percentage of gun-related homicides. Individuals who are at risk for gun violence are difficult to identify and successfully treat. The incidence, and perhaps the demographics, of gun violence vary substantially from state to state. We make a case for Connecticut physicians to study gun violence at the state level. We recommend that Connecticut physicians promote and expand upon the American Academy of Pediatrics' recommendation for creating a "safe home environment. "We suggest that guns be secured in all homes in which there are children. In addition we suggest that guns be voluntarily removed from homes in which there are individuals with a history of violence, threats of violence, depression, drug and/or alcohol abuse, and individuals with major mental illnesses who are not cooperating with therapy.

  7. One nanosecond pulsed electron gun systems

    International Nuclear Information System (INIS)

    Koontz, R.F.

    1979-02-01

    At SLAC there has been a continuous need for the injection of very short bunches of electrons into the accelerator. Several time-of-flight experiments have used bursts of short pulses during a normal 1.6 micro-second rf acceleration period. Single bunch beam loading experiments made use of a short pulse injection system which included high power transverse beam chopping equipment. Until the equipment described in this paper came on line, the basic grid-controlled gun pulse was limited to a rise time of 7 nanoseconds and a pulse width of 10 nanoseconds. The system described here has a grid-controlled rise time of less than 500 pico-seconds, and a minimum pulse width of less than 1 nanosecond. Pulse burst repetition rate has been demonstrated above 20 MHz during a 1.6 microsecond rf accelerating period. The order-of-magnitude increase in gun grid switching speed comes from a new gun design which minimizes lead inductance and stray capacitance, and also increases gun grid transconductance. These gun improvements coupled with a newly designed fast pulser mounted directly within the gun envelope make possible subnanosecond pulsing of the gun

  8. Ready, Fire, Aim: The College Campus Gun Fight

    Science.gov (United States)

    Birnbaum, Robert

    2013-01-01

    The question of whether guns should be permitted on college and university campuses in the United States reflects the tension between two competing perspectives. America has both a robust gun culture and an equally robust (if less well known) gun-control culture. The gun culture is as American as apple pie: There may be as many as 300 million…

  9. Gun Safety Management with Patients at Risk for Suicide

    Science.gov (United States)

    Simon, Robert I.

    2007-01-01

    Guns in the home are associated with a five-fold increase in suicide. All patients at risk for suicide must be asked if guns are available at home or easily accessible elsewhere, or if they have intent to buy or purchase a gun. Gun safety management requires a collaborative team approach including the clinician, patient, and designated person…

  10. Correlates of Gun Involvement and Aggressiveness among Adolescents.

    Science.gov (United States)

    Ding, Cody S.; Nelsen, Edward A.; Lassonde, Cynthia T.

    2002-01-01

    Investigated adolescents' aggressiveness in relation to their experiences, beliefs, and attitudes concerning gun use, also noting family composition, relationships with parents, and emotionality as correlates of gun involvement and aggression. Student surveys indicated links between gun ownership and recreational use, beliefs about gun use, and…

  11. DC photoemission electron guns as ERL sources

    International Nuclear Information System (INIS)

    Sinclair, Charles K.

    2006-01-01

    Very-high-voltage DC electron guns, delivering moderate duration bunches from photoemission cathodes, and followed by conventional drift bunching and acceleration, offer a practical solution for an ERL injector. In a variant of this scheme, a DC gun is placed in close proximity to a superconducting RF accelerator cavity, with few or no active elements between the gun and cavity. The principal technical challenge with such electron guns arises from field emission from the cathode electrode and its support structure. Field emission may result in voltage breakdown across the cathode-anode gap, or a punch-through failure of the insulator holding off the cathode potential, as well as lesser though still serious problems. Various means to mitigate these problems are described. The operational lifetime of high quantum efficiency photocathodes in these guns is determined by the vacuum conditions, through phenomena such as chemical poisoning and ion back-bombardment. Minimization of the field strength on electrode structures pushes high-voltage DC guns toward large dimensions and, correspondingly, large outgassing loads, but it is also true that these guns offer many opportunities for achieving excellent vacuum conditions. Good solutions to vacuum problems that had previously limited cathode lifetime have been demonstrated in recent years. Designs for DC guns presently in use and planned for the near future will be described. The parameters necessary for a 100 mA average current, very-high-voltage DC gun with a photocathode operational lifetime greater than 100 h appear to be within reach, but have yet to be demonstrated. A 1 A average current source with good cathode operational lifetime will require developments beyond the present state-of-the-art

  12. Gun ownership and firearm-related deaths.

    Science.gov (United States)

    Bangalore, Sripal; Messerli, Franz H

    2013-10-01

    A variety of claims about possible associations between gun ownership rates, mental illness burden, and the risk of firearm-related deaths have been put forward. However, systematic data on this issue among various countries remain scant. Our objective was to assess whether the popular notion "guns make a nation safer" has any merits. Data on gun ownership were obtained from the Small Arms Survey, and for firearm-related deaths from a European detailed mortality database (World Health Organization), the National Center for Health Statistics, and others. Crime rate was used as an indicator of safety of the nation and was obtained from the United Nations Surveys of Crime Trends. Age-standardized disability-adjusted life-year rates due to major depressive disorder per 100,000 inhabitants with data obtained from the World Health Organization database were used as a putative indicator for mental illness burden in a given country. Among the 27 developed countries, there was a significant positive correlation between guns per capita per country and the rate of firearm-related deaths (r = 0.80; P guns per capita per country and crime rate (r = .33), or between mental illness and crime rate (r = 0.32; P = .11). In a linear regression model with firearm-related deaths as the dependent variable with gun ownership and mental illness as independent covariates, gun ownership was a significant predictor (P guns per capita per country was a strong and independent predictor of firearm-related death in a given country, whereas the predictive power of the mental illness burden was of borderline significance in a multivariable model. Regardless of exact cause and effect, however, the current study debunks the widely quoted hypothesis that guns make a nation safer. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Design and development of a pierce electron gun

    International Nuclear Information System (INIS)

    Bhattacharjee, D.; Tiwari, R.; Nayak, B.; Tillu, A.R.; Jayaprakash, D.; Mishra, R.L.; Mittal, K.C.; Chakravarthy, D.P.; Gantayet, L.M.

    2011-01-01

    An electron gun is designed and developed using the Pierce configuration for the focusing electrode. Simulations were carried out using CST Particle Studio. The Gun is a thermionic type electron gun with indirect heating of the LaB6 cathode. The gun is capable of delivering a beam current of 500 mA at 50 kV with a beam size of less than 3.5 mm. It was tested on the gun test bench. This paper presents the gun design, particle simulations study, testing of the gun on test bench and integration with the ECIL 9 MeV linac. (author)

  14. Performance of the Brookhaven photocathode rf gun

    International Nuclear Information System (INIS)

    Batchelor, K.; Ben-Zvi, I.; Fernow, R.C.; Fischer, J.; Fisher, A.S.; Gallardo, J.; Ingold, G.; Kirk, H.G.; Leung, K.P.; Malone, R.; Pogorelsky, I.; Srinivasan-Rao, T.; Rogers, J.; Tsang, T.; Sheehan, J.; Ulc, S.; Woodle, M.; Xie, J.; Zhang, R.S.; Lin, L.Y.; McDonald, K.T.; Russell, D.P.; Hung, C.M.; Wang, X.J.

    1991-01-01

    The Brookhaven Accelerator Test Facility (ATF) uses a photocathode rf gun to provide a high-brightness electron beam intended for FEL and laser-acceleration experiments. The rf gun consists of 1 1/2 cells driven at 2856 MHz in π-mode with a maximum cathode field of 100 MV/m. To achieve long lifetimes, the photocathode development concentrates on robust metals such as copper, yttrium and samarium. We illuminate these cathodes with a 10-ps, frequency-quadrupled Nd:YAG laser. We describe the initial operation of the gun, including measurements of transverse and longitudinal emittance, quantum efficiencies, and peak current. The results are compared to models

  15. Evaluation of Smart Gun Technologies preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, D.R.

    1996-01-01

    The Smart Gun Technology Project has a goal to eliminate the capability of an unauthorized user from firing a law enforcement officer`s firearm by implementing {open_quote}smart{close_quote} technologies. Smart technologies are those that can in some manner identify an officer. This report will identify, describe, and grade various technologies as compared to the requirements that were obtained from officers. This report does not make a final recommendation for a smart gun technology, nor does it give the complete design of a smart gun system.

  16. Advances in DC photocathode electron guns

    International Nuclear Information System (INIS)

    Dunham, B. M.; Hartmann, P.; Kazimi, R.; Liu, H.; Poelker, B. M.; Price, J. S.; Rutt, P. M.; Schneider, W. J.; Sinclair, C. K.

    1999-01-01

    At Jefferson Lab, a DC photoemission gun using GaAs and GaAs-like cathodes provides a source of polarized electrons for the main accelerator. The gun is required to produce high average current with long operational lifetimes and high system throughput. Recent work has shown that careful control of the parameters affecting cathode lifetime lead to dramatic improvements in source operation. These conditions include vacuum and the related effect of ion backbombardment, and precise control of all of the electrons emitted from the cathode. In this paper, we will review recent results and discuss implications for future photocathode guns

  17. Advances in DC photocathode electron guns

    International Nuclear Information System (INIS)

    Dunham, B.M.; Hartmann, P.; Kazimi, R.; Liu, H.; Poelker, B.M.; Price, J.S.; Rutt, P.M.; Schneider, W.J.; Sinclair, C.K.

    1999-01-01

    At Jefferson Lab, a DC photoemission gun using GaAs and GaAs-like cathodes provides a source of polarized electrons for the main accelerator. The gun is required to produce high average current with long operational lifetimes and high system throughput. Recent work has shown that careful control of the parameters affecting cathode lifetime lead to dramatic improvements in source operation. These conditions include vacuum and the related effect of ion backbombardment, and precise control of all of the electrons emitted from the cathode. In this paper, we will review recent results and discuss implications for future photocathode guns. copyright 1999 American Institute of Physics

  18. Advances in DC photocathode electron guns

    International Nuclear Information System (INIS)

    Dunham M, Bruce; Heartmann, P.; Reza Kazimi; Hongxiu Liu; Poelker, B.M.; Price, J.S.; Rutt, P.M.; Schneider, W.J.; Sinclair K, Charles

    1998-01-01

    At Jefferson Lab, a DC photoemission gun using GaAs and GaAs-like cathodes provides a source of polarized electrons for the main accelerator. The gun is required to produce high average current with long operational lifetimes and high system throughout. Recent work has shown that careful control of the parameters affecting cathode lifetime lead to dramatic improvements in source operation. These conditions include vacuum and the related effect of ion back-bombardment, and precise control of all of the electrons emitted from the cathode. In this paper, the authors will review recent results and discuss implications for future photocathode guns

  19. "Is there a gun in the home?" Assessing the risks of gun ownership in older adults.

    Science.gov (United States)

    Pinholt, Ellen M; Mitchell, Joshua D; Butler, Jane H; Kumar, Harjinder

    2014-06-01

    An important ethical and safety concern that geriatricians, primary care providers, and home health professionals need to address is gun ownership by elderly adults. Those aged 65 and older now have the highest rate of gun ownership in America, and they also have a high prevalence of depression and suicide. Dementia can add additional layers of risk. Even older gun owners who are otherwise intellectually intact may benefit from information about gun safety with the increasing numbers of children being cared for by grandparents. Health professionals should ask patients, "Is there a gun in the home?" in the clinic and during home visits. Healthcare professionals must have knowledge and skills to address safe gun ownership in elderly adults. The 5 L's (Locked, Loaded, Little children, feeling Low, Learned owner) will assist professionals in addressing all aspects of safe ownership. © 2014, Copyright the Authors Journal compilation © 2014, The American Geriatrics Society.

  20. [Effects of different water potentials on leaf gas exchange and chlorophyll fluorescence parameters of cucumber during post-flowering growth stage].

    Science.gov (United States)

    Lin, Lu; Tang, Yun; Zhang, Ji-tao; Yan, Wan-li; Xiao, Jian-hong; Ding, Chao; Dong, Chuan; Ji, Zeng-shun

    2015-07-01

    Impacts of different substrate water potentials (SWP) on leaf gas exchange and chlorophyll fluorescence parameters of greenhouse cucumber during its post-flowering growth stage were analyzed in this study. The results demonstrated that -10 and -30 kPa were the critical values for initiating stomatal and non-stomatal limitation of drought stress, respectively. During the stage of no drought stress (-10 kPa gas exchange parameters and chlorophyll fluorescence parameters were not different significantly among treatments. During the stage of stomatal limitation of drought stress (-30 kPaefficiency (ε), transpiration rate (Tr), carboxylation efficiency (CE), maximum Rubisco-limited rate of carboxylation (Vc max), maximum rate of electron transport (Jmax), rate of triosephosphate utilization (VTPU), maximum and actual quantum efficiency of PSII (ΦPSII, and Fv/Fm) and photochemical quenching (qP) decreased, but the light compensation point (LCP), dark respiration rate (Rd), carbon dioxide compensation point (CCP), stomatal limitation value (LS), instantaneous water use efficiency (WUEi) and non-photochemical quenching (qN) increased. In this stage, gas exchange parameters changed faster than chlorophyll fluorescence parameters and differed significantly among treatments. During the stage of non-stomatal limitation of drought stress (-45 kPa≤SWP ≤ -30 kPa), with the decrease of SWP, light saturation point (LSP), Rd, CE, Vcmax, VTPU, LS, WUEi, ΦpPSII, Fv/Fm and qp decreased, while CCP, Ci and qN increased. In this stage, chlorophyll fluorescence parameters changed faster than gas exchange parameters and differed significantly among treatments. In production of greenhouse cucumber, -10 and -5 kPa should be the lower and upper limit value of irrigation, respectively. The stomatal limitation of drought stress could be relieved by irrigation before SWP decreased to -30 kPa. While, the non-stomatal injury of drought stress would be unrecoverable once SWP decreased to

  1. Camouflaged Collectives: Managing Stigma and Identity at Gun Events

    Directory of Open Access Journals (Sweden)

    Sarah Jane Blithe

    2017-02-01

    Full Text Available Gun violence persists in the United States, claiming lives and escalating healthcare costs. This article seeks to contribute to social justice work on the “gun problem” by studying gun collectives. To understand gun culture and to identify gun violence reduction strategies, we study places where gun owners organize – legal (and sometimes illegal settings that facilitate dialogue about gun issues. Based on participant observation and collaborative event ethnography at gun shows and a private shooting party, this analysis presents findings about the practices gun collective members use to manage stigma. We conclude that when participants in gun events attempt to subvert core stigma through everyday stigma management practices, they effectively facilitate the unfettered exchange of potentially dangerous goods, promote the invisibility of oppressive structures, and normalize violence.

  2. Gas

    International Nuclear Information System (INIS)

    1996-01-01

    The French government has decided to modify the conditions of extension of local natural gas authorities to neighbouring districts. The European Union is studying the conditions of internal gas market with the objective of more open markets although considering public service requirements

  3. Electric gun: a new method for generating shock pressures in excess of 1 TPa

    International Nuclear Information System (INIS)

    Steinberg, D.; Chau, H.; Dittbenner, G.; Weingart, R.

    1978-01-01

    By combining the electrically-driven, flying-plate, high-explosive initiator with well-known gas-gun technology, a novel method of generating and measuring shock pressures greater than 1 TPa has been developed. Called the electric gun, this system is competitive with laser or nuclear-driven, shock-wave, equation-of-state experiments in the 1 to 5 TPa range. Compared to those other methods, it has the advantage of simplicity, high precision, and low cost. In addition, its small size and low total energy allow it to be easily contained for experiments with toxic materials

  4. Rail gun powered by an integral explosive generator

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, D.R.; Fowler, C.M.

    1979-01-01

    We propose the use of a rail gun powered by an explosive magnetic flux compression generator built into the rail gun itself in which the rails of the gun are driven together behind the projectile by explosives. The magnetic field established between the rails by an initial current supplied by an external source at the breech of the gun is trapped and compressed by the collapsing rails to accelerate the projectile down the bore of the gun.

  5. Rail gun powered by an integral explosive generator

    International Nuclear Information System (INIS)

    Peterson, D.R.; Fowler, C.M.

    1979-01-01

    We propose the use of a rail gun powered by an explosive magnetic flux compression generator built into the rail gun itself in which the rails of the gun are driven together behind the projectile by explosives. The magnetic field established between the rails by an initial current supplied by an external source at the breech of the gun is trapped and compressed by the collapsing rails to accelerate the projectile down the bore of the gun

  6. Development of a capacitor powered rail gun for hypervelocity impact studies

    International Nuclear Information System (INIS)

    Shrader, J.E.

    1983-01-01

    Boeing has built and tested several rail gun designs using two different capacitor banks as power sources. For each design, the muzzle velocity predicted with the Boeing Electromagnetic Gun code (BEMG) matched the measured muzzle velocity within 5%, providing gas sealing between the rails and the dielectric of the barrel was maintained. This did not validate the model, but gave reasonable confidence in it. Using the BEMG model, a parametric study was conducted to determine the sensitivity of muzzle velocities between 2 and 5 km/s to the input variables. A practical point design was assumed, and then each parameter individually varied while the others were held constant. The point design assumed an initial velocity of 0.5 km/s and an inductance per unit length (L') of 0.8 x 10 -6 H/m. Other parameters were similar to the earlier designs. The earlier designs tested had no initial velocity, and an L' of 0.3 x 10 6 H/m. A gas gun was assumed to produce the initial velocity, and resulted in only modest increases in muzzle velocity. However, it eliminated a separate make switch, since a foil across the back of the projectile becomes a make switch, and it is expected to substantially reduce rail erosion near the breech of the gun. Rail erosion was a significant problem for repeated firings in earlier designs. The parametric study showed that for the velocities of interest, increasing L' was the single best way to improve gun performance. In a practical gun, this will be achieved by making a two turn barrel, rather than a single turn barrel. The results of this study will be used to design, build and test a small gun (about 9 mm bore) using a 150 kJ capacitor bank as a power source. Using the experience gained with this gun, a large gun (about 20 mm bore) will be designed, built and tested using a 1.3 MJ capacitor bank

  7. Solid state cesium ion guns for surface studies

    International Nuclear Information System (INIS)

    Souzis, A.E.; Carr, W.E.; Kim, S.I.; Seidl, M.

    1990-01-01

    Three cesium ion guns covering the energy range of 5--5000 V are described. These guns use a novel source of cesium ions that combine the advantages of porous metal ionizers with those of aluminosilicate emitters. Cesium ions are chemically stored in a solid electrolyte pellet and are thermionically emitted from a porous thin film of tungsten at the surface. Cesium supply to the emitting surface is controlled by applying a bias across the pellet. A total charge of 10.0 C can be extracted, corresponding to greater than 2000 h of lifetime with an extraction current of 1.0 μA. This source is compact, stable, and easy to use, and produces a beam with >99.5% purity. It requires none of the differential pumping or associated hardware necessary in designs using cesium vapor and porous tungsten ionizers. It has been used in ultrahigh-vacuum (UHV) experiments at pressures of -10 Torr with no significant gas load. Three different types of extraction optics are used depending on the energy range desired. For low-energy deposition, a simple space-charge-limited planar diode with a perveance of 1x10 -7 A/V 3/2 is used. Current densities of 10.0 μA/cm 2 at the exit aperture for energies ≤20 V are typical. This type of source provides an alternative to vapor deposition with the advantage of precise flux calibration by integration of the ion current. For energies from 50 to 500 V and typical beam radii of 0.5 to 0.2 mm, a high perveance Pierce-type ion gun is used. This gun was designed with a perveance of 1x10 -9 A/V 3/2 and produces a beam with an effective temperature of 0.35 eV. For the energy range of 0.5 to 5 keV, the Pierce gun is used in conjunction with two Einzel lenses, enabling a large range of imaging ratios to be obtained. Beam radii of 60 to 300 μm are typical for beam currents of 50 nA to 1.0 μA

  8. Pros and cons of an expansion of the natural gas system in the Nordic Countries - sensitivity analysis of the scenario results from stage one of the Nordleden project

    International Nuclear Information System (INIS)

    2001-12-01

    The report shows that the maximum economic profit from a transnordic gas grid amounts to 5-30 billion SEK (0.5-3 billion USD), depending on scenarios. This holds even under relatively strict CO 2 limitations. The profit is in the same range as the profits from emissions trading or from free trade in electricity in the Nordic market. In absolute numbers, the profit increases with increased energy demand. The natural gas supply could amount to about 300 TWh in year 2030, if the price at the border does not surpass 70 SEK/MWh (7 USD/MWh). The main expansion would be in central power and heat production. However, the report also shows that the transnordic gas grid could become a burden for the Nordic energy system, as the profit could be negative in the case where the investment is done according to the design case, but the gas price gets higher. The worst case could result in a loss of about 30 billion SEK. However, it is probably more realistic to assume that the market actors try to minimize their own risks through long term contracts with fixed prices and volumes, leading to a transfer of the risk to the society as a whole, being forced to renounce cheaper solutions for reaching the environmental goals in the case where natural gas becomes a more expensive fuel than supposed in the planning stage. The corresponding risk is much lower from a CO 2 point of view, i.e. if future CO 2 reduction limit become more strict than in the planning stage, the value of the gas grid is only marginally affected. Sensitivity analysis where the Nordic cooperation is widened to include trade in electricity (which already is a fact) and emission rights show that the optimum natural gas supply is affected, but to a small degree only. The net effect is a certain redistribution of the natural gas use between the countries

  9. Greenhouse gas emissions during plantation stage of palm oil-based biofuel production addressing different land conversion scenarios in Malaysia.

    Science.gov (United States)

    Kusin, Faradiella Mohd; Akhir, Nurul Izzati Mat; Mohamat-Yusuff, Ferdaus; Awang, Muhamad

    2017-02-01

    The environmental impacts with regard to agro-based biofuel production have been associated with the impact of greenhouse gas (GHG) emissions. In this study, field GHG emissions during plantation stage of palm oil-based biofuel production associated with land use changes for oil palm plantation development have been evaluated. Three different sites of different land use changes prior to oil palm plantation were chosen; converted land-use (large and small-scales) and logged-over forest. Field sampling for determination of soil N-mineralisation and soil organic carbon (SOC) was undertaken at the sites according to the age of palm, i.e. 21 years (mature oil palms). The field data were incorporated into the estimation of nitrous oxide (N 2 O) and the resulting CO 2 -eq emissions as well as for estimation of carbon stock changes. Irrespective of the land conversion scenarios, the nitrous oxide emissions were found in the range of 6.47-7.78 kg N 2 O-N/ha resulting in 498-590 kg CO 2 -eq/ha. On the other hand, the conversion of tropical forest into oil palm plantation has resulted in relatively higher GHG emissions (i.e. four times higher and carbon stock reduction by >50%) compared to converted land use (converted rubber plantation) for oil palm development. The conversion from previously rubber plantation into oil palm plantation would increase the carbon savings (20% in increase) thus sustaining the environmental benefits from the palm oil-based biofuel production.

  10. Gun- and Non-Gun-Related Violence Exposure and Risk for Subsequent Gun Carrying Among Male Juvenile Offenders.

    Science.gov (United States)

    Beardslee, Jordan; Mulvey, Edward; Schubert, Carol; Allison, Paul; Infante, Arynn; Pardini, Dustin

    2018-04-01

    Although studies have found that youth exposed to violence are more likely to carry guns than non-exposed youth, this association could be due to common causal factors or other pre-existing differences between individuals. In this study, within-individual change models were used to determine whether juvenile offenders exhibit an increased propensity to carry a firearm after being exposed to gun violence and/or non-gun violence. The advantage of this approach is all time-invariant factors are eliminated as potential confounders. A sample of 1,170 racially/ethnically diverse male juvenile offenders was recruited in Arizona and Pennsylvania (14-19 years old at recruitment). Participants were interviewed every 6 months for 3 years followed by 4 annual assessments. The outcome was gun carrying and the primary predictors were exposure to gun violence and non-gun violence. Time-varying covariates included exposure to peers who carried guns, exposure to peers who engaged in other (non-gun) criminal acts, developmental changes in gun carrying, and changes in gun carrying from incarceration or institutionalization. Adolescent offenders were significantly more likely to carry a gun in recall periods after exposure to gun violence, but not after exposure to non-gun violence. Effect of gun violence on carrying was significant throughout adolescence and young adulthood and could not be accounted for by time-varying and time-invariant confounders. Interventions to decrease illegal gun carrying should target young men in medical and mental health settings who experience or witness gun violence and those living in communities with high rates of gun violence. Copyright © 2018 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.

  11. Uudised : Guns N' Roses Soomes. Valmis ulmeraadio

    Index Scriptorium Estoniae

    2006-01-01

    Ameerika hard-rock-bändi Guns N' Roses kontserdist 5. juulil Hartwall Areenal Soomes. Kord kuus on Ulmeplaatide kodulehekülel www. ulmeplaadid.ee võimalus kuulata ulmeraadiot, kus esitusel eesti kergemuusika

  12. Mass Shootings, Mental Illness, and Gun Control.

    Science.gov (United States)

    Philpott-Jones, Sean

    2018-03-01

    In the wake of the Stoneman Douglas School shooting, Republican and Democratic leaders-like the American electorate they represent-remain sharply divided in their responses to gun violence. They are united in their condemnation of these mass shootings, but they disagree about whether stricter or looser gun control laws are the answer. Those on the right side of the political aisle suggest that the issue is one of mental illness rather than gun control. Conversely, those who are more liberal or progressive in their political learnings are quick to condemn attempts to reframe the issue of mass shootings as a mental health problem. Both sides are wrong. Mass shootings are indeed partially a mental health problem, albeit one poorly addressed by our current laws and policies. But the solution to mass shootings also needs to consider strategies that may reduce gun violence in general. © 2018 The Hastings Center.

  13. Ballistic Rail Gun Soft Recovery Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Ballistic Rail Gun Soft Recovery Facility accommodates a 155mm Howitzer, fired horizontally into a 104-foot long water trough to slow the projectile and recover...

  14. Prestressed Carbon Fiber Composite Overwrapped Gun Tube

    National Research Council Canada - National Science Library

    Littlefield, Andrew; Hyland, Edward

    2006-01-01

    .... Using composite materials not only directly removes weight from the gun tube but, by better balancing the tube, allows the use of smaller drive systems, thus further enhancing the system weight loss...

  15. Cost Estimate for Gun Liner Emplacement

    Science.gov (United States)

    2011-08-01

    the gun tube. (The Rowan cost estimate includes the extra thermal soak for the explosive bonding process.) The cost for the extra stress relief... nuts for optimum performance. GUIDANCE SYSTEM:  Cylinder guidance is provide by the rod bushing

  16. Arc Plasma Gun With Coaxial Powder Feed

    Science.gov (United States)

    Zaplatynsky, Isidor

    1988-01-01

    Redesigned plasma gun provides improved metallic and ceramic coatings. Particles injected directly through coaxial bore in cathode into central region of plasma jet. Introduced into hotter and faster region of plasma jet.

  17. The Impact of Banning Juvenile Gun Possession.

    OpenAIRE

    Marvell, Thomas B

    2001-01-01

    A 1994 federal law bans possession of handguns by persons under 18 years of age. Also in 1994, 11 states passed their own juvenile gun possession bans. Eighteen states had previously passed bans, 15 of them between 1975 and 1993. These laws were intended to reduce homicides, but arguments can be made that they have no effect on or that they even increase the homicide rate. This paper estimates the laws' impacts on various crime measures, primarily juvenile gun homicide victimizations and suic...

  18. The effects of staged gas combustion on NO{sub x} formation; L'effet de la combustion etagee sur la formation de NO{sub x}

    Energy Technology Data Exchange (ETDEWEB)

    Wopera, A. [University of Miskolc (Hungary); Sandor, P.; Sevcsik, M. [Dunaferr Co. (Hungary)

    2000-07-01

    The use of energy involves air pollution unavoidably. As a result of the ongoing change of the structure of the fuels used in Hungary, the decisive majority of the heat treatment and annealing furnaces in our industrial companies operate with natural gas. With natural gas heating if the firing control is proper, only one important air pollutant, the nitrogen monoxide comes into being. NO{sub x} emission of firing processes may be reduced by staged fuel combustion. One of the traditional activities in the field of energetics is the utilization of the energy content of waste fuels. The recovery of the energy content of waste gases, which can be used as fuels, should be examined from both a heat technology and an environment protection point of view. There is the possibility of technological heat utilization when it is mixed with gases of high thermal value. Its utilization as combination gas also makes it necessary to examine how the waste gases change the polluting effects of natural gas. Our research work studied the NO{sub x} formation at different rate of mixing of natural gas and waste gases and the effect of secondary combustion chamber at a two-stage burner. (authors)

  19. Electrothermal plasma gun as a pellet injector

    International Nuclear Information System (INIS)

    Kincaid, R.W.; Bourham, M.A.

    1994-01-01

    The NCSU electrothermal plasma gun SIRENS has been used to accelerate plastic (Lexan polycarbonate) pellets, to determine the feasibility of the use of electrothermal guns as pellet injectors. The use of an electrothermal gun to inject frozen hydrogenic pellets requires a mechanism to provide protective shells (sabots) for shielding the pellet from ablation during acceleration into and through the barrel of the gun. The gun has been modified to accommodate acceleration of the plastic pellets using special acceleration barrels equipped with diagnostics for velocity and position of the pellet, and targets to absorb the pellet's energy on impact. The length of the acceleration path could be varied between 15 and 45 cm. The discharge energy of the electrothermal gun ranged from 2 to 6 kJ. The pellet velocities have been measured via a set of break wires. Pellet masses were varied between 0.5 and 1.0 grams. Preliminary results on 0.5 and 1.0 g pellets show that the exit velocity reaches 0.9 km/s at 6 kJ input energy to the source. Higher velocities of 1.5 and 2.7 km/s have been achieved using 0.5 and 1.0 gm pellets in 30 cm long barrel, without cleaning the barrel between the shots

  20. Are "goods for guns" good for the community? An update of a community gun buyback program.

    Science.gov (United States)

    Green, Jonathan; Damle, Rachelle N; Kasper, Rebecca E; Violano, Pina; Manno, Mariann; Nazarey, Pradeep P; Aidlen, Jeremy T; Hirsh, Michael P

    2017-08-01

    Gun violence remains a leading cause of death in the United States. Community gun buyback programs provide an opportunity to dispose of extraneous firearms. The purpose of this study was to understand the demographics, motivation, child access to firearms, and household mental illness of buyback participants in hopes of improving the program's effectiveness. A 2015 Injury Free Coalition for Kids gun buyback program which collaborated with local police departments was studied. We administered a 23-item questionnaire survey to gun buyback participants assessing demographic characteristics, motivation for relinquishing firearms, child firearm accessibility, and mental illness/domestic violence history. A total of 186 individuals from Central/Western Massachusetts turned in 339 weapons. Participants received between US $25 and US $75 in gift cards dependent on what type of gun was turned in, with an average cost of $41/gun. A total of 109 (59%) participants completed the survey. Respondents were mostly white (99%), men (90%) and first-time participants in the program (85.2%). Among survey respondents, 54% turned in firearms "for safety reasons." Respondents reported no longer needing/wanting their weapons (47%) and approximately one in eight participants were concerned the firearm(s) were accessible to children. Most respondents (87%) felt the program encouraged neighborhood awareness of firearm safety. Three of every five participants reported that guns still remained in their homes; additionally, 21% where children could potentially access them and 14% with a history of mental illness/suicide/domestic violence in the home. Gun buybacks can provide a low-cost means of removing unwanted firearms from the community. Most participants felt their homes were safer after turning in the firearm(s). In homes still possessing guns, emphasis on secure gun storage should continue, increasing the safety of children and families. The results of this survey also provided new

  1. The design and development of a ring cathode electron gun as an evaporation source

    International Nuclear Information System (INIS)

    Poyner, G.T.

    1976-01-01

    The RG2 ring cathode gun is a simple application of electron beam heating. The gun described was developed to provide a relatively inexpensive source for evaporating a range of metals and oxides which were otherwise difficult or impossible to evaporate by conventional resistance heating. Following several stages of improvement the gun was progressively reduced in size and the 'optics', or focusing, improved so that in its existing state an area of approximately 2mm diameter is heated. It was decided to limit the accelerating voltage as far as possible to minimize the practical problems associated with its operation and also the manufacture of the power supply. As development proceeded it became apparent that the relatively low accelerating voltage chosen improved the flexibility of the gun. Two versions are manufactured, the first, equipped with a six position rotary hearth, and the second, utilising a single hearth, is intended to be used as one of a pair. The latter design was reduced in size even further in order to minimize the distance between two adjacent guns. (author)

  2. Separating Batterers and Guns: A Review and Analysis of Gun Removal Laws in 50 States

    Science.gov (United States)

    Frattaroli, Shannon; Vernick, Jon S.

    2006-01-01

    Firearms play an important role in lethal domestic violence incidents. The authors review state laws regarding two policies to separate batterers from firearms: laws authorizing police to remove firearms when responding to a domestic violence complaint ("police gun removal laws") and laws authorizing courts to order guns removed from batterers…

  3. Relationship between licensing, registration, and other gun sales laws and the source state of crime guns.

    Science.gov (United States)

    Webster, D W; Vernick, J S; Hepburn, L M

    2001-09-01

    To determine the association between licensing and registration of firearm sales and an indicator of gun availability to criminals. Tracing data on all crime guns recovered in 25 cities in the United States were used to estimate the relationship between state gun law categories and the proportion of crime guns first sold by in-state gun dealers. In cities located in states with both mandatory registration and licensing systems (five cities), a mean of 33.7% of crime guns were first sold by in-state gun dealers, compared with 72.7% in cities that had either registration or licensing but not both (seven cities), and 84.2% in cities without registration or licensing (13 cites). Little of the difference between cities with both licensing and registration and cities with neither licensing nor registration was explained by potential confounders. The share of the population near a city that resides in a neighboring state without licensing or registration laws was negatively associated with the outcome. States with registration and licensing systems appear to do a better job than other states of keeping guns initially sold within the state from being recovered in crimes. Proximity to states without these laws, however, may limit their impact.

  4. Gun Carrying by High School Students in Boston, MA: Does Overestimation of Peer Gun Carrying Matter?

    Science.gov (United States)

    Hemenway, David; Vriniotis, Mary; Johnson, Renee M.; Miller, Matthew; Azrael, Deborah

    2011-01-01

    This paper investigates: (1) whether high school students overestimate gun carrying by their peers, and (2) whether those students who overestimate peer gun carrying are more likely to carry firearms. Data come from a randomly sampled survey conducted in 2008 of over 1700 high school students in Boston, MA. Over 5% of students reported carrying a…

  5. Gun suicide by young people in California: descriptive epidemiology and gun ownership.

    Science.gov (United States)

    Wright, Mona A; Wintemute, Garen J; Claire, Barbara E

    2008-12-01

    We studied the 336 firearm suicides occurring in California in 1997-1999 to persons under age 21. The gun used was most often owned by the victim or a family member living in the victim's household. Prevention efforts should focus on gun ownership and accessibility.

  6. The hired gun expert witness.

    Science.gov (United States)

    Beck, M

    1994-04-01

    This article briefly discusses the role of the expert physician witness at trial and describes what is emerging as the physician professional witness (AKA hired gun). The trial court's powers to evaluate the professionalism and objectivity of an expert witness are examined in light of a recent Western District Missouri Court of Appeals case. This case, while limited to its peculiar set of facts, permitted both a hearing and production of documents of a physician who had been hired to testify. This article reviews the role of the expert physician witness in Missouri litigation in light of recent caselaw outlining discovery procedures to monitor use of professional witnesses. The term "professional witness" does not refer to witnesses who are professionals, but rather to persons who make their entire living witnessing. The Missouri Court of Appeals ruling in State ex rel. Lichtor v. Clark, 845 S.W.2d (Mo.App. W.D. 1992) elucidates the Missouri Courts' authority in sorting out unprofessional physicians who would offer unobjective expert testimony. While this particular article is intended for medical readership and discusses expert physician witnesses, expert witnesses can come from any profession including engineering, accounting, nursing, etc. It might thus be assumed that the Lichtor Court's procedure may be applied to any expert whose objectivity has been put into question.

  7. Design and Characterization of Thin Stainless Steel Burst Disks for Increasing Two-Stage Light Gas Launcher Efficiency

    Science.gov (United States)

    Tylka, Jonathan M.; Johnson, Kenneth L.; Henderson, Donald; Rodriguez, Karen

    2012-01-01

    Laser etched 300 series Stainless Steel Burst Disks (SSBD) ranging between 0.178 mm (0.007-in.) and 0.508mm (0.020-in.) thick were designed for use in a 17-caliber two-stage light gas launcher. First, a disk manufacturing method was selected using a combination of wire electrical discharge machining (EDM) to form the blank disks and laser etching to define the pedaling fracture pattern. Second, a replaceable insert was designed to go between the SSDB and the barrel. This insert reduced the stress concentration between the SSBD and the barrel, providing a place for the petals of the SSDB to open, and protecting the rifling on the inside of the barrel. Thereafter, a design of experiments was implemented to test and characterize the burst characteristics of SSBDs. Extensive hydrostatic burst testing of the SSBDs was performed to complete the design of experiments study with one-hundred and seven burst tests. The experiment simultaneously tested the effects of the following: two SSBD material states (full hard, annealed); five SSBD thicknesses 0.178, 0.254, 0.305, 0.381 mm (0.007, 0.010, 0.012, 0.015, 0.020-in.); two grain directions relative); number of times the laser etch pattern was repeated (varies between 5-200 times); two heat sink configurations (with and without heat sink); and, two barrel configurations (with and without insert). These tests resulted in the quantification of the relationship between SSBD thickness, laser etch parameters, and desired burst pressure. Of the factors investigated only thickness and number of laser etches were needed to develop a mathematical relationship predicting hydrostatic burst pressure of disks using the same barrel configuration. The fracture surfaces of two representative SSBD bursts were then investigated with a scanning electron microscope, one burst hydrostatically in a fixture and another dynamically in the launcher. The fracture analysis verified that both burst conditions resulted in a ductile overload failure

  8. The development of the gas sector in Tanzania and Mozambique. The early stages of two asymmetric experiments

    International Nuclear Information System (INIS)

    Auge, Benjamin

    2016-10-01

    As huge gas deposits have been discovered in 2010 in Mozambique and in Tanzania, and as the oil barrel price has dramatically decreased since mid-2014, this report, based on interview with local economic, industrial and political actors, describes the very different situations faced by these two countries regarding the development of their gas sector. First, Mozambique possesses four times more gas than Tanzania. Secondly, they display very different relationships between political power and private investors. Therefore the Mozambican project grows at a much higher rate than the Tanzanian one. The author thus proposes presentations of the status and projects of gas exploitation in these both countries, by mentioning involved actors (notably large oil companies), economic and political relationships between them, assessments and perspectives in terms of gas production

  9. Development of Wien filter for small ion gun of surface analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bahng, Jungbae [Department of Physics, Kyungpook National University, Daegu 702-701 (Korea, Republic of); Busan Center, Korea Basic Science Institute, Busan 609-735 (Korea, Republic of); Hong, Jonggi; Choi, Myoung Choul; Won, Mi-Sook; Lee, Byoung-Seob, E-mail: bslee@kbsi.re.kr [Busan Center, Korea Basic Science Institute, Busan 609-735 (Korea, Republic of)

    2016-02-15

    The gas cluster ion beam (GCIB) and liquid metal ion beam have been studied in the context of ion beam usage for analytical equipment in applications such as X-ray photoelectron spectroscopy and secondary ion mass spectroscopy (SIMS). In particular, small ion sources are used for the secondary ion generation and ion etching. To set the context to this study, the SIMS project has been launched to develop ion-gun based analytical equipment for the Korea Basic Science Institute. The objective of the first stage of the project is the generation of argon beams with a GCIB system [A. Kirkpatrick, Nucl. Instrum. Methods Phys. Res., Sect. B 206, 830–837 (2003)] that consists of a nozzle, skimmer, ionizer, acceleration tube, separation system, transport system, and target. The Wien filter directs the selected cluster beam to the target system by exploiting the velocity difference of the generated particles from GCIB. In this paper, we present the theoretical modeling and three-dimensional electromagnetic analysis of the Wien filter, which can separate Ar{sup +}{sub 2500} clusters from Ar{sup +}{sub 2400} to Ar{sup +}{sub 2600} clusters with a 1-mm collimator.

  10. Development of Wien filter for small ion gun of surface analysis

    Science.gov (United States)

    Bahng, Jungbae; Hong, Jonggi; Choi, Myoung Choul; Won, Mi-Sook; Lee, Byoung-Seob

    2016-02-01

    The gas cluster ion beam (GCIB) and liquid metal ion beam have been studied in the context of ion beam usage for analytical equipment in applications such as X-ray photoelectron spectroscopy and secondary ion mass spectroscopy (SIMS). In particular, small ion sources are used for the secondary ion generation and ion etching. To set the context to this study, the SIMS project has been launched to develop ion-gun based analytical equipment for the Korea Basic Science Institute. The objective of the first stage of the project is the generation of argon beams with a GCIB system [A. Kirkpatrick, Nucl. Instrum. Methods Phys. Res., Sect. B 206, 830-837 (2003)] that consists of a nozzle, skimmer, ionizer, acceleration tube, separation system, transport system, and target. The Wien filter directs the selected cluster beam to the target system by exploiting the velocity difference of the generated particles from GCIB. In this paper, we present the theoretical modeling and three-dimensional electromagnetic analysis of the Wien filter, which can separate Ar+2500 clusters from Ar+2400 to Ar+2600 clusters with a 1-mm collimator.

  11. Stall/surge dynamics of a multi-stage air compressor in response to a load transient of a hybrid solid oxide fuel cell-gas turbine system

    Science.gov (United States)

    Azizi, Mohammad Ali; Brouwer, Jacob

    2017-10-01

    A better understanding of turbulent unsteady flows in gas turbine systems is necessary to design and control compressors for hybrid fuel cell-gas turbine systems. Compressor stall/surge analysis for a 4 MW hybrid solid oxide fuel cell-gas turbine system for locomotive applications is performed based upon a 1.7 MW multi-stage air compressor. Control strategies are applied to prevent operation of the hybrid SOFC-GT beyond the stall/surge lines of the compressor. Computational fluid dynamics tools are used to simulate the flow distribution and instabilities near the stall/surge line. The results show that a 1.7 MW system compressor like that of a Kawasaki gas turbine is an appropriate choice among the industrial compressors to be used in a 4 MW locomotive SOFC-GT with topping cycle design. The multi-stage radial design of the compressor enhances the ability of the compressor to maintain air flow rate during transient step-load changes. These transient step-load changes are exhibited in many potential applications for SOFC/GT systems. The compressor provides sustained air flow rate during the mild stall/surge event that occurs due to the transient step-load change that is applied, indicating that this type of compressor is well-suited for this hybrid application.

  12. Progress of the Rossendorf SRF Gun Project

    CERN Document Server

    Teichert, J; Büttig, H; Janssen, D; Lehnert, U; Michel, P; Möller, K; Murcek, P; Schneider, C; Schurig, R; Staufenbiel, F; Xiang, R

    2005-01-01

    A superconducting rf photo electron injector (SRF gun) is under development at the Forschungszentrum Rossendorf. The project aims at several issues: improvement of the beam quality for the ELBE superconducting electron linac, demonstration of feasibility of this gun type, investigation of critical components, and parameter studies for future application (BESSY-FEL, 4GLS). In 2005, a substantial progress has been made. The two 3.5-cell niobium cavities for the gun have been delivered from the company ACCEL. The main parts for gun cryostat like vacuum vessel, cryogenic and magnetic shields are ready. Test benches for the cathode cooling system and the cavity tuner are being assembled. The photo cathode preparation lab has been arranged, and the diagnostic beam line has been designed (see T. Kamps et al., this conference). After delivering the gun cavities, their rf properties are being measured at room temperature and the warm tuning is being carried out. The set-up for this treatment and measurement as well as...

  13. A coaxial plasma gun with a controllable streaming velocity in the range of 2-90 km secsup(-1)

    International Nuclear Information System (INIS)

    Venkataramani, N.; Mattoo, S.K.

    1981-01-01

    A coaxial plasma gun capable of producing a plasma stream of velocity ranging between 2 and 90 km secsup(-1) is described. The velocity of the stream is controlled by a variable (0.2-25 Ω) NaCl salt solution resistor in the discharge path of the energy storage connected across the gun. The resistor dissipates an energy of 200 J in the gun discharge current pulse period of 25 μ sec and the consequent heating and dissociation of the electrolyte are insignificant. The electron density of the plasma stream ranges between 10 18 and 10 19 msup(-3) and the temperature is approximately 10 eV. The total number of ions per plasma pulse is approximately 10 18 . The energy transfer efficiency of the gun is approximately 10%. The low transfer efficiency is explained in terms of the experimental requirements and the performance of the valve which admits gas into the gun region. For evaluation of the performance of the gun, several diagnostics have been deployed. A specially designed high voltage capacitor probe is described. (author)

  14. Mathematical models of gas-dynamic and thermophysical processes in underground coal mining at different stages of mine development

    OpenAIRE

    М. В. Грязев; Н. М. Качурин; С. А. Воробьев

    2017-01-01

    New trends have been traced and the existing ones refined regarding filtration and diffusive motion of gases in coal beds and surrounding rock, spontaneous heating of coal and transport of gas traces by ventilation currents in operating coal mines. Mathematical models of gas-dynamic and thermophysical processes inside underworked territories after mine abandonment have been justified. Mathematical models are given for feasible air feeding of production and development areas, as well as for th...

  15. To Your Health: NLM update transcript - Gun safety strategies

    Science.gov (United States)

    ... transcript040918.html To Your Health: NLM update Transcript Gun safety strategies : 04/09/2018 To use the ... on weekly topics. An evidence-based, public health gun safety strategy that is consistent with second amendment ...

  16. Tri-Service Green Gun Barrel (PP 1074)

    National Research Council Canada - National Science Library

    Rusch, Lawrence F

    2003-01-01

    ...) PP 1074 Tri-Service Green Gun Barrel. The program's goal was to develop an environmentally friendly process for depositing wear and erosion resistant materials onto gun bores replacing the current hazardous aqueous electro-deposition...

  17. Simple gun for vapor deposition of organic thin films

    International Nuclear Information System (INIS)

    Sato, N.; Seki, K.; Inokuchi, H.

    1987-01-01

    A simple evaporation gun for preparing organic thin films was fabricated using commercially available parts of an electron gun for a TV Braun tube. The device permits sample heating to be easily controlled because of the small heat capacity

  18. Numerical modeling of deflagration mode in coaxial plasma guns

    Science.gov (United States)

    Sitaraman, Hariswaran; Raja, Laxminarayan

    2012-10-01

    Pulsed coaxial plasma guns have been used in several applications in the field of space propulsion, nuclear fusion and materials processing. These devices operate in two modes based on the delay between gas injection and breakdown initiation. Larger delay led to the plasma detonation mode where a compression wave in the form of a luminous front propagates from the breech to the muzzle. Shorter delay led to the more efficient deflagration mode characterized by a relatively diffuse plasma with higher resistivity. The overall physics of the discharge in the two modes of operation and in particular the latter remain relatively unexplored. Here we perform a computational modeling study by solving the non-ideal Magneto-hydrodynamics equations for the quasi-neutral plasma in the coaxial plasma gun. A finite volume formulation on an unstructured mesh framework with an implicit scheme is used to do stable computations. The final work will present details of important species in the plasma, particle energies and Mach number at the muzzle. A comparison of the plasma parameters will be made with the experiments reported in ref. [1]. [4pt] [1] F. R. Poehlmann et al., Phys. Plasmas 17, 123508 (2010)

  19. Secondary emission electron gun using external primaries

    Science.gov (United States)

    Srinivasan-Rao, Triveni [Shoreham, NY; Ben-Zvi, Ilan [Setauket, NY

    2009-10-13

    An electron gun for generating an electron beam is provided, which includes a secondary emitter. The secondary emitter includes a non-contaminating negative-electron-affinity (NEA) material and emitting surface. The gun includes an accelerating region which accelerates the secondaries from the emitting surface. The secondaries are emitted in response to a primary beam generated external to the accelerating region. The accelerating region may include a superconducting radio frequency (RF) cavity, and the gun may be operated in a continuous wave (CW) mode. The secondary emitter includes hydrogenated diamond. A uniform electrically conductive layer is superposed on the emitter to replenish the extracted current, preventing charging of the emitter. An encapsulated secondary emission enhanced cathode device, useful in a superconducting RF cavity, includes a housing for maintaining vacuum, a cathode, e.g., a photocathode, and the non-contaminating NEA secondary emitter with the uniform electrically conductive layer superposed thereon.

  20. Pulser for the Tevatron electron lens gun

    Energy Technology Data Exchange (ETDEWEB)

    Iouri Terechkine et al.

    2004-05-18

    To compensate for beam-beam interaction in Tevatron, an ''electron lens'' is considered to be an effective instrument. When a bunch of electrons with energy in the range (10-16) kV is overlapping with a bunch of antiprotons, the resulting focusing force for antiprotons can be adjusted by changing the electron beam current and by profiling its radial distribution. There exist several scenarios of how the system must function. According to one of them, an electron gun that supplies electrons must be fed by voltage pulses that follow with the frequency of antiproton bunches circulating in the Tevatron, which is about 2.5 MHz. To provide focusing tailored for each individual antiproton bunch, a modulator of the gun (pulser) must allow pulse-to-pulse voltage change. This report will cover main approaches to a design of a pulser for use with the gun of the Tevatron Electron Lens.

  1. Photocathode operation of a thermionic RF gun

    International Nuclear Information System (INIS)

    Thorin, S.; Cutic, N.; Lindau, F.; Werin, S.; Curbis, F.

    2009-01-01

    The thermionic RF gun using a BaO cathode at the MAX-lab linac injector has been successfully commissioned for additional operation as a photocathode gun. By retaining the BaO cathode, lowering the temperature below thermal emission and illuminating it with a UV (263 nm) 9 ps laser pulse a reduced emittance and enhanced emission control has been achieved. Measurements show a normalised emittance of 5.5 mm mrad at 200 pC charge and a maximum quantum efficiency of 1.1x10 -4 . The gun is now routinely switched between storage ring injections in thermionic mode and providing a beam for the MAX-lab test FEL in photocathode mode.

  2. Improved DC Gun and Insulator Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Neubauer, Michael [Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2015-01-11

    Many user facilities such as synchrotron radiation light sources and free electron lasers rely on DC high voltage photoguns with internal field gradients as high as 10 to 15 MV/m. These high gradients often lead to field emission which poses serious problems for the photocathode used to generate the electron beam and the ceramic insulators used to bias the photocathode at high voltage. Ceramic insulators are difficult to manufacture, require long commissioning times, and have poor reliability, in part because energetic electrons bury themselves in the ceramic causing a buildup of charge and eventual puncture, and also because large diameter ceramics are difficult to braze reliably. The lifetimes of photo cathodes inside high current DC guns exhibiting field emission are limited to less than a hundred hours. Reducing the surface gradients on the metals reduces the field emission, which serves to maintain the required ultrahigh vacuum condition. A novel gun design with gradients around 5 MV/m and operating at 350 kV, a major improvement over existing designs, was proposed that allows for the in-situ replacement of photo cathodes in axially symmetric designs using inverted ceramics. In this project, the existing JLAB CEBAF asymmetric gun design with an inverted ceramic support was modeled and the beam dynamics characterized. An improved structure was designed that reduces the surface gradients and improves the beam optics. To minimize the surface gradients, a number of electrostatic gun designs were studied to determine the optimum configuration of the critical electrodes within the gun structure. Coating experiments were carried out to create a charge dissipative coating for cylindrical ceramics. The phase II proposal, which was not granted, included the design and fabrication of an axially symmetric DC Gun with an inverted ceramic that would operate with less than 5 MV/m at 350 kV and would be designed with an in-situ replaceable photo-cathode.

  3. Interpreting the Empirical Evidence on Illegal Gun Market Dynamics

    OpenAIRE

    Braga, Anthony A.; Wintemute, Garen J.; Pierce, Glenn L.; Cook, Philip J.; Ridgeway, Greg

    2012-01-01

    Thousands of Americans are killed by gunfire each year, and hundreds of thousands more are injured or threatened with guns in robberies and assaults. The burden of gun violence in urban areas is particularly high. Critics suggest that the results of firearm trace data and gun trafficking investigation studies cannot be used to understand the illegal supply of guns to criminals and, therefore, that regulatory and enforcement efforts designed to disrupt illegal firearms markets are futile in ad...

  4. Gun utopias? Firearm access and ownership in Israel and Switzerland

    OpenAIRE

    Rosenbaum, Janet

    2011-01-01

    The 2011 attempted assassination of a US representative renewed the national gun control debate. Gun advocates claim that mass-casualty events are mitigated and deterred with three policies: (1) permissive gun laws, (2) widespread gun ownership, (3) encouragement of armed civilians who can intercept shooters, and cite Switzerland and Israel as exemplars. We evaluate these claims with analysis of International Crime Victimization Survey (ICVS) data and translation of laws and original source m...

  5. Investigating the effect of blade sweep and lean in one stage of an industrial gas turbine׳s transonic compressor

    Directory of Open Access Journals (Sweden)

    M.A. Neshat

    2015-12-01

    Full Text Available In this paper, the simultaneous effects of the sweep and lean of the blades in one stage of a transonic compressor on its performance have been investigated. Then, with the help of numerical solution, fluid flows over these two modified geometries generated from the original sample were analyzed. Considering the applied constraints, the two generated rotor geometries have different geometrical characteristics; so that in rotor No. 1, the blade has a backward sweep and it is less affected by lean, while in the modified rotor No. 2, the blade has a forward sweep and it is more affected by lean. In the first sample, it is observed that the stage efficiency increases by 0.5% for operating design, while the stall margin reduces, and the chocking mass flow rate diminishes by 1.5%. Also regarding the second modified blade, the results indicate that the stall margin increases, the choking flow rate at the nominal rotational speed of the stage increases by 0.18% and the stage efficiency increases by 1%. The comparison of numerical results also shows that, in the first modified rotor, the pressure ratio of the stage diminishes by 0.01%; while in the second sample, the pressure ratio of the stage increases by the same amount. These results were then compared with the experimental results, showing a good agreement.

  6. The design of gridded pierce guns for accelerators

    International Nuclear Information System (INIS)

    True, R.

    1985-01-01

    It is vital to employ ultra-laminar beams in electron linacs to maximize charge transport to the target. This paper presents numerical and experimental design techniques which have led to significant improvements in gridded Pierce guns used in microwave tubes and electron linacs. The paper concludes with two gun/injector concepts which have demonstrated enhanced performance over standard triode Pierce guns

  7. Youth, Guns, and the Juvenile Justice System. Research Report.

    Science.gov (United States)

    Butts, Jeffrey; Coggeshall, Mark; Gouvis, Caterina; Mears, Daniel; Travis, Jeremy; Waul, Michelle; White, Ruth

    This report documents trends in youth gun violence and the response within the justice system, noting the growing variety of data resources available to investigate the effect of new gun laws on youth, communities, and public safety. The first section reviews recent trends, examining the major wave of gun violence in the United States during the…

  8. Klystron - Space-charge limited flow, guns, Perveance

    International Nuclear Information System (INIS)

    Isagawa, S.

    1999-01-01

    This paper treats Thermionic emission, Cathode as an e - emitter, Space-charge limited effect and 3/2 power law, Perveance, Beam spread due to space charge, Pierce guns, Magnetically immersed guns, Method of gun design including simulations, and Examples, mainly treating E3786, which attendees will operate above 1 MW-CW in a practical exercise course at KEK. (author). 74 refs

  9. Should Gun Safety Be Taught in Schools? Perspectives of Teachers

    Science.gov (United States)

    Obeng, Cecilia

    2010-01-01

    Background: Gun-related injuries and deaths among children occur at disproportionately high rates in the United States. Children who live in homes with guns are the most likely victims. This study describes teachers' views on whether gun safety should be taught to children in the preschool and elementary years. Methods: A total of 150 survey…

  10. 78 FR 11902 - Review of Gun Safety Technologies

    Science.gov (United States)

    2013-02-20

    ... DEPARTMENT OF JUSTICE Office of Justice Programs [OJP (NIJ) Docket No. 1615] Review of Gun Safety...'s Plan to reduce gun violence released on January 16, 2013, the U.S. Department of Justice, Office... emerging gun safety technologies and plans to issue a report on the availability and use of those...

  11. Gun Violence and Children: Factors Related To Exposure and Trauma.

    Science.gov (United States)

    Slovak, Karen

    2002-01-01

    Study investigated relationship between access to firearms and parental monitoring on rural youths' exposure to gun violence, and examined the effect of gun violence exposure on mental health. Results indicated a substantial number were exposed to gun violence. Exposure was related to firearm access and parental monitoring. Implications for social…

  12. Frequency of Guns in the Households of High School Seniors

    Science.gov (United States)

    Coker, Ann L.; Bush, Heather M.; Follingstad, Diane R.; Brancato, Candace J.

    2017-01-01

    Background: In 2013, President Obama lifted the federal ban on gun violence research. The current study provides one of the first reports to estimate household gun ownership as reported by youth. Methods: In this cohort study of 3,006 high school seniors from 24 schools, we examined the frequency of household guns ownership. Results: About 65%…

  13. Study of Control Grid Thermionic Cathode RF Gun

    CERN Document Server

    Xiao, Jin; Ming, Li; Xinfan, Yang; Xumin, Shen; Yanan, Chen; Zhou, Xu

    2004-01-01

    In this paper, the beam loading effect of RF Gun was analyzed. To minimize the energy spread, the grid control RF Gun was introduced. The result shows that the grid congrol RF Gun can increase electron beam within 1% energy spread.

  14. High-energy electron impact apparatus utilizing a simple diode electron gun assembly

    International Nuclear Information System (INIS)

    Peterson, R.B.; Pidwerbekki, D.

    1992-01-01

    An electron impact facility based on a ribbon filament cathode, simple diode gun, and thin aluminium foil window is described. The facility is designed for the study of gas phase electron impact phenomena at pressures up to one atmosphere in a variety of gases. Of particular interest is the simple design of the electron gun for generating electron beams having energies up to 100 keV and currents up to 5 mA. The beam is magnetically collimated and directed through a thin aluminium foil which is used as the vacuum-gas interface to an impact chamber. Maximum power delivered to the impact region depends on the thickness of the foil window. Using an 8.4 μm thick aluminium foil, approximately 150 W can be delivered to the impact chamber. Thermal heating of the foil by the electron beam is the limiting factor restricting higher effective power transmission. (Author)

  15. Mercury emission and plant uptake of trace elements during early stage of soil amendment using flue gas desulfurization materials.

    Science.gov (United States)

    A pilot-scale field study was carried out to investigate the distribution of Hg and other selected elements in the three potential mitigation pathways, i.e., emission to ambient air, uptake by surface vegetation (i.e., grass), and rainfall infiltration, after flue gas desulfurization (FGD) material ...

  16. Hydrogen-rich gas as a product of two-stage co-gasification of lignite/waste mixtures

    Czech Academy of Sciences Publication Activity Database

    Straka, Pavel; Bičáková, Olga

    2014-01-01

    Roč. 39, č. 21 (2014), s. 10987-10995 ISSN 0360-3199 Institutional support: RVO:67985891 Keywords : co-gasification * waste plastics * lignite * hydrogen-rich gas Subject RIV: DM - Solid Waste and Recycling Impact factor: 3.313, year: 2014 http://authors.elsevier.com/sd/article/S0360319914014025

  17. A 1 kW-class multi-stage heat-driven thermoacoustic cryocooler system operating at liquefied natural gas temperature range

    Science.gov (United States)

    Zhang, L. M.; Hu, J. Y.; Wu, Z. H.; Luo, E. C.; Xu, J. Y.; Bi, T. J.

    2015-07-01

    This article introduces a multi-stage heat-driven thermoacoustic cryocooler capable of reaching cooling capacity about 1 kW at liquefied natural gas temperature range without any moving mechanical parts. The cooling system consists of an acoustically resonant double-acing traveling wave thermoacoustic heat engine and three identical pulse tube coolers. Unlike other traditional traveling wave thermoacoustic heat engines, the acoustically resonant double-acting thermoacoustic heat engine is a closed-loop configuration consists of three identical thermoacoustic conversion units. Each pulse tube cooler is bypass driven by one thermoacoustic heat engine unit. The device is acoustically completely symmetric and therefore "self-matching" for efficient traveling-wave thermoacoustic conversion. In the experiments, with 7 MPa helium gas as working gas, when the heating temperature reaches 918 K, total cooling capacity of 0.88 kW at 110 K is obtained with a resonant frequency of about 55 Hz. When the heating temperature is 903 K, a maximum total cooling capacity at 130 K of 1.20 kW is achieved, with a thermal-to-cold exergy efficiency of 8%. Compared to previously developed heat-driven thermoacoustic cryocoolers, this device has higher thermal efficiency and higher power density. It shows a good prospect of application in the field of natural gas liquefaction and recondensation.

  18. Modular design of a reprocessing plant dissolver off-gas system. Variations, flexibility and stage of development

    International Nuclear Information System (INIS)

    Henrich, E.; Huefner, R.

    1984-01-01

    Simple and economic control of the volatile radionuclides in a reprocessing plant requires two equally important prerequisites: suitable processing in the plant head-end and reliable operation of the dissolver off-gas (DOG) purification system. A small number of DOG purification modules was selected from various alternatives. The major selection criteria are removal efficiency, simplicity, convenient operating conditions and flexibility that provide compatibility with other off-gas treatment steps, subsequent waste treatment and different processing modes in the head-end. The behaviour of noxious materials was investigated in nitric acid off-gas scrubbers of different design and for a wide range of operating modes and conditions. A concentration range of nitric acid from very dilute to hyperazeotropic concentrations and a temperature range from -55 deg. C to above room temperature as well as the use of hydrogen peroxide were studied on an engineering scale. Nitrous gases and iodine can be removed to the trace level at special operating modes. Aerosol and iodine filters are discussed briefly. A selective absorption process using CF 2 Cl 2 solvent for noble gas and 14 C removal was developed on a laboratory scale. It operates at low temperatures and atmospheric pressure. Xe and Kr were separated using two absorption columns. Pilot-plant scale noble gas scrubbers are under construction and are being integrated into the existing test facility. A series of process steps has been chosen for integrated process demonstration runs on an engineering scale. The integrated DOG system consists of several scrubbers and filters operating at atmospheric pressure. The temperature decreases stepwise, without producing large changes in the opposite direction, providing compatibility within the process train

  19. Release isentrope measurements with the LLNL electric gun

    Energy Technology Data Exchange (ETDEWEB)

    Gathers, G.R.; Osher, J.E.; Chau, H.H.; Weingart, R.C.; Lee, C.G.; Diaz, E.

    1987-06-01

    The liquid-vapor coexistence boundary is not well known for most metals because the extreme conditions near the critical point create severe experimental difficulties. The isentropes passing through the liquid-vapor region typically begin from rather large pressures on the Hugoniot. We are attempting to use the high velocities achievable with the Lawrence Livermore National Laboratory (LLNL) electric gun to obtain these extreme states in aluminum and measure the release isentropes by releasing into a series of calibrated standards with known Hugoniots. To achieve large pressure drops needed to explore the liquid-vapor region, we use argon gas for which Hugoniots have been calculated using the ACTEX code, as one of the release materials.

  20. Green plasticizers for multibase gun propellants (Lecture)

    NARCIS (Netherlands)

    Schoolderman, C.; Driel, C.A. van; Zebregs, M.

    2007-01-01

    TNO Defence, Security and Safety has a long history of research on gun propellants. Areas investigated are formulating (new ingredients, optimization), manufacturing, charge design and lifetime assessment [1,2,3,4,5]. In conventional propellants inert plasticizers are used to alter performance,

  1. Toward a terahertz-driven electron gun

    Science.gov (United States)

    Huang, W. Ronny; Nanni, Emilio A.; Ravi, Koustuban; Hong, Kyung-Han; Fallahi, Arya; Wong, Liang Jie; Keathley, Phillip D.; Zapata, Luis E.; Kärtner, Franz X.

    2015-01-01

    Femtosecond electron bunches with keV energies and eV energy spread are needed by condensed matter physicists to resolve state transitions in carbon nanotubes, molecular structures, organic salts, and charge density wave materials. These semirelativistic electron sources are not only of interest for ultrafast electron diffraction, but also for electron energy-loss spectroscopy and as a seed for x-ray FELs. Thus far, the output energy spread (hence pulse duration) of ultrafast electron guns has been limited by the achievable electric field at the surface of the emitter, which is 10 MV/m for DC guns and 200 MV/m for RF guns. A single-cycle THz electron gun provides a unique opportunity to not only achieve GV/m surface electric fields but also with relatively low THz pulse energies, since a single-cycle transform-limited waveform is the most efficient way to achieve intense electric fields. Here, electron bunches of 50 fC from a flat copper photocathode are accelerated from rest to tens of eV by a microjoule THz pulse with peak electric field of 72 MV/m at 1 kHz repetition rate. We show that scaling to the readily-available GV/m THz field regime would translate to monoenergetic electron beams of ~100 keV. PMID:26486697

  2. Capital Punishment, Gun Ownership, and Homicide.

    Science.gov (United States)

    Kleck, Gary

    1979-01-01

    Examines two controversial questions related to the problem of interpersonal violence in America: (1) Does use of the death penalty exert any measurable influence on the rate of homicide in the United States? (2) What relationship, if any, exists between the level of gun ownership and the level of homicide violence? (Author)

  3. Magnetic guns with cylindrical permanent magnets

    DEFF Research Database (Denmark)

    Vokoun, David; Beleggia, Marco; Heller, Luděk

    2012-01-01

    The motion of a cylindrical permanent magnet (projectile) inside a tubular permanent magnet, with both magnets magnetized axially, illustrates nicely the physical principles behind the operation of magnetic guns. The force acting upon the projectile is expressed semi-analytically as derivative...

  4. Guns on Campus: A Chilling Effect

    Science.gov (United States)

    Mash, Kenneth M.

    2013-01-01

    The author of this article observes that, while much has been written on the overall topic of safety with regard to allowing guns on college campuses, little has been said about how allowing the possession of deadly weapons can create a "chilling effect" on academic discussions. This article considers how some universities have…

  5. College Students Opinions on Gun Violence.

    Science.gov (United States)

    Lewis, Rhonda K; LoCurto, Jamie; Brown, Kyrah; Stowell, David; Maryman, J'Vonnah; Dean, Amber; McNair, Thoi; Ojeda, Debbie; Siwierka, Julia

    2016-06-01

    Gun violence and control issues have become serious public health problems. This study gathered the opinions from 419 college students from a Midwestern University. Participants were asked about beliefs about purchasing assault weapons, beliefs about bringing handguns to college campuses and beliefs about contributing factors that lead to gun violence. Participants completed surveys online. The findings showed that overall 54 % of respondents believed that military assault weapons should be banned and 53 % agree that teachers should be allowed to carry a registered handgun on campus. There were statistically significant differences between males and females on these issues. For instance, females believed military assault weapons and high capacity magazines should be banned more than 1.9 times (p = .004) p gun violence were decline in parenting and family values (17 %), gang involvement (14 %), bullying (13.8 %) and guns being easy to obtain (13.8 %). Limitations and implications for policy work are discussed.

  6. Youth Suicide and Guns. Firearm Facts.

    Science.gov (United States)

    Duker, Laurie, Ed.

    Whether or not a suicide attempt results in death depends in large part on the method chosen. If a teenager attempts suicide with a gun, his or her death is nearly guaranteed. This brief fact sheet presents data on firearms and suicide, the third leading cause of death for adolescents and young adults in the United States. Any number of societal…

  7. Issue Management and the Australian Gun Debate.

    Science.gov (United States)

    Reynolds, Christopher

    1997-01-01

    Examines the rise and fall of media coverage of the issues of gun control and political conflict in Australia after an incident of mass murder in April 1996. Aims to reveal the issue management process that occurred and the hidden agendas that motivated the political and media activity. Demonstrates the media's role in the creation of issue…

  8. Cerebral damage caused by nail gun injury

    Directory of Open Access Journals (Sweden)

    Andersen Chris Hedeman

    2016-06-01

    Full Text Available Background Accidents with nail guns are rather common, especially in the construction industry. Most injuries involve the extremities and several present with intracerebral injuries. When the patient is unconscious, it can be a big challenge to determine whether the injury is an accident, self-inflicted or a criminal act.

  9. How Sociology Texts Address Gun Control

    Science.gov (United States)

    Tonso, William R.

    2004-01-01

    William R. Tonso has chosen an issue that he knows something about to examine how sociology textbooks address controversy. Appealing for gun control is fashionable, but it is at odds with a fondness that ordinary Americans have for their firearms--one that is supported by a growing body of research on deterrence to crime. There are two sides to…

  10. Safety Plan for Schools: No Guns

    Science.gov (United States)

    Shah, Nirvi

    2013-01-01

    In a pre-emptive move against a school safety proposal from the National Rifle Association that is expected to include a call for more people trained and approved to carry guns at schools, a coalition of civil rights and education groups unveiled its own safety plan last week. It seeks the creation of positive school climates, thoughtful and…

  11. Nerf Guns Strike a Nerve on Campuses

    Science.gov (United States)

    Young, Jeffrey R.

    2008-01-01

    Killing zombies on campus just isn't as much fun as it used to be. Students at Bowling Green State University once carried Nerf guns for a week each semester, shooting the zombies before the creatures could tag them. Participants were seen by most bystanders as nerdy but harmless kids who liked role-playing. These days, bright plastic Nerf guns…

  12. Accidental Bolt Gun Injury to Femur - A Case Report

    OpenAIRE

    Kattimani, Ravi Prasad; Shetty, Sanath; Mirza, Humayun

    2016-01-01

    Introduction: Bolt gun or slaughterer?s guns are used in meat industry for ?humane killing? of animals. Injuries caused by bolt gun are rare, reported exclusively from central European countries. We report a case of 28 year old male, who accidentally shot himself with a bolt gun to his right thigh. Case Report: A 28 years old male presented to our Accident and Emergency department after accidental injury to his right thigh with bolt gun. He had an entry wound measuring 2 cm in length and 1 cm...

  13. Development of the electron gun control system of SSRF

    International Nuclear Information System (INIS)

    Zhou Dayong; Lin Guoqiang; Liu Dekang; Shen Liren

    2010-01-01

    An electron gun is the key part of a linac, the beam quality of which depends on beam quality of the electron gun, hence the need of a stable control system of the electron gun to ensure its safe operation.In this paper, we report our progresses in developing the linac's electron gun control system of Shanghai Synchrotron Radiation Facility (SSRF). It uses PLC as the device controllers, with the monitoring software developed on EPICS. The whole system is connected by Ethernet. The PLC and Ethernet technology ensures good reliability and easy maintenance of the electron gun control system. (authors)

  14. Formation of compact toroidal plasmas by magnetized coaxial plasma gun injection into an oblate flux conserver

    International Nuclear Information System (INIS)

    Turner, W.C.; Goldenbaum, G.C.; Granneman, E.H.A.; Hartman, C.W.; Prono, D.S.; Taska, J.; Smith, A.C. Jr.

    1980-01-01

    Initial results are reported on the formation of compact toroidal plasmas in an oblate shaped metallic flux conserver. A schematic of the experimental apparatus is shown. The plasma injector is a coaxial plasma gun with solenoid coils wound on the inner and outer electrodes. The electrode length is 100 cm, the diameter of the inner (outer) electrode is 19.3 cm (32.4 cm). Deuterium gas is puffed into the region between electrodes by eight pulsed valves located on the outer electrode 50 cm from the end of the gun. The gun injects into a cylindrically symmetrical copper shell (wall thickness = 1.6 mm) which acts as a flux conserver for the time scale of experiments reported here. The copper shell consists of a transition cylinder 30 cm long, 34 cm in diameter, a cylindrical oblate pill box 40 cm long, 75 cm in diameter and a downstream cylinder 30 cm long, 30 cm in diameter. The gap between the gun and transition cylinder is 6 cm. An axial array of coils outside the vacuum chamber can be used to establish an initial uniform bias field

  15. Two-dimensional computational modeling of high-speed transient flow in gun tunnel

    Science.gov (United States)

    Mohsen, A. M.; Yusoff, M. Z.; Hasini, H.; Al-Falahi, A.

    2018-03-01

    In this work, an axisymmetric numerical model was developed to investigate the transient flow inside a 7-meter-long free piston gun tunnel. The numerical solution of the gun tunnel was carried out using the commercial solver Fluent. The governing equations of mass, momentum, and energy were discretized using the finite volume method. The dynamic zone of the piston was modeled as a rigid body, and its motion was coupled with the hydrodynamic forces from the flow solution based on the six-degree-of-freedom solver. A comparison of the numerical data with the theoretical calculations and experimental measurements of a ground-based gun tunnel facility showed good agreement. The effects of parameters such as working gases and initial pressure ratio on the test conditions in the facility were examined. The pressure ratio ranged from 10 to 50, and gas combinations of air-air, helium-air, air-nitrogen, and air-CO2 were used. The results showed that steady nozzle reservoir conditions can be maintained for a longer duration when the initial conditions across the diaphragm are adjusted. It was also found that the gas combination of helium-air yielded the highest shock wave strength and speed, but a longer test time was achieved in the test section when using the CO2 test gas.

  16. Patterns of gun deaths across US counties 1999-2013.

    Science.gov (United States)

    Kalesan, Bindu; Galea, Sandro

    2017-05-01

    We examined the socio-demographic distribution of gun deaths across 3143 counties in 50 United States' states to understand the spatial patterns and correlates of high and low gun deaths. We used aggregate counts of gun deaths and population in all counties from 1999 to 2013 from the Centers for Disease Control and Prevention's Wide-ranging Online Data for Epidemiologic Research (WONDER). We characterized four levels of gun violence, as distinct levels of gun death rates of relatively safe, unsafe, violent, and extremely violent counties, based on quartiles of 15-year county-specific gun death rates per 100,000 and used negative binomial regression models allowing clustering by state to calculate incidence rate ratios and 95% confidence intervals (95% CIs). Most states had at least one violent or extremely violent county. Extremely violent gun counties were mostly rural, poor, predominantly minority, had high unemployment rate and homicide rate. Overall, homicide rate was significantly associated with gun deaths (incidence rate ratios = 1.08, 95% CI = 1.06-1.09). In relatively safe counties, this risk was 1.09 (95% CI = 1.05-1.13) and in extremely violent gun counties was 1.03 (95% CI = 1.03-1.04). There are broad differences in gun death rates across the United States representing different levels of gun death rates in each state with distinct socio-demographic profiles. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Association Between Substance Use and Gun-Related Behaviors.

    Science.gov (United States)

    Chen, Danhong; Wu, Li-Tzy

    2016-01-01

    Gun-related violence is a public health concern. This study synthesizes findings on associations between substance use and gun-related behaviors. Searches through PubMed, Embase, and PsycINFO located 66 studies published in English between 1992 and 2014. Most studies found a significant bivariate association between substance use and increased odds of gun-related behaviors. However, their association after adjustment was mixed, which could be attributed to a number of factors such as variations in definitions of substance use and gun activity, study design, sample demographics, and the specific covariates considered. Fewer studies identified a significant association between substance use and gun access/possession than other gun activities. The significant association between nonsubstance covariates (e.g., demographic covariates and other behavioral risk factors) and gun-related behaviors might have moderated the association between substance use and gun activities. Particularly, the strength of association between substance use and gun activities tended to reduce appreciably or to become nonsignificant after adjustment for mental disorders. Some studies indicated a positive association between the frequency of substance use and the odds of engaging in gun-related behaviors. Overall, the results suggest a need to consider substance use in research and prevention programs for gun-related violence. © The Author 2016. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Storage Practices of US Gun Owners in 2016.

    Science.gov (United States)

    Crifasi, Cassandra K; Doucette, Mitchell L; McGinty, Emma E; Webster, Daniel W; Barry, Colleen L

    2018-04-01

    To examine gun storage practices and factors influencing those practices among gun owners. We conducted a nationally representative online survey of US gun owners (n = 1444) in 2016 to assess gun storage practices and attitudes, factors influencing storage practices, and groups that might effectively communicate regarding safe storage. We generated descriptive statistics by using cross-tabulations and used logistic regression to estimate characteristics that influenced safe storage practices. Forty-six percent of gun owners reported safely storing all of their guns. Factors associated with higher odds of reporting safe storage were having a child in the home (adjusted odds ratio [AOR] = 1.44; 95% confidence interval [CI] = 1.03, 2.03), only owning handguns (AOR = 1.84; 95% CI = 1.24, 2.73), and reporting that storage decisions were influenced by a gun safety course (AOR = 2.05; 95% CI = 1.54, 2.74) or discussions with family members (AOR = 1.39; 95% CI = 1.05, 1.86). Gun owners ranked law enforcement, hunting or outdoors groups, active-duty military, and the National Rifle Association as most effective in communicating safe storage practices. Public health campaigns to promote safe gun storage should consider partnering with groups that garner respect among gun owners for their experience with safe use of guns.

  19. Modeling and optimization of integrated exhaust gas recirculation and multi-stage waste heat recovery in marine engines

    DEFF Research Database (Denmark)

    Kyriakidis, Fotis; Sørensen, Kim; Singh, Shobhana

    2017-01-01

    is optimized to utilize the maximum waste heat recovery. The Genetic algorithm and fmincon active-set algorithm are used to optimize the design and operation parameters for the two steam cycles. The optimization aims to find the theoretically optimal combination of the pressure levels and pinch......Waste heat recovery combined with exhaust gas recirculation is a promising technology that can address both the issue of NOx (nitrogen oxides) reduction and fuel savings by including a pressurized boiler. In the present study, a theoretical optimization of the performance of two different...... configurations of steam Rankine cycles, with integrated exhaust gas recirculation for a marine diesel engine, is presented. The first configuration employs two pressure levels and the second is configured with three-pressure levels. The models are developed in MATLAB based on the typical data of a large two...

  20. Modeling and optimization of integrated exhaust gas recirculation and multi-stage waste heat recovery in marine engines

    DEFF Research Database (Denmark)

    Kyriakidis, Fotis; Sørensen, Kim; Singh, Shobhana

    2017-01-01

    Waste heat recovery combined with exhaust gas recirculation is a promising technology that can address both the issue of NOx (nitrogen oxides) reduction and fuel savings by including a pressurized boiler. In the present study, a theoretical optimization of the performance of two different....... For the three-pressure level configuration, the optimum pressure levels are found to be 33.5/10.5/4.7 bara. The amount of waste heat recovery from the pressurized boiler is significantly higher than from the main boiler for both cycles. It is, therefore, concluded that the three-pressure level steam cycle...... configurations of steam Rankine cycles, with integrated exhaust gas recirculation for a marine diesel engine, is presented. The first configuration employs two pressure levels and the second is configured with three-pressure levels. The models are developed in MATLAB based on the typical data of a large two...

  1. Gun utopias? Firearm access and ownership in Israel and Switzerland.

    Science.gov (United States)

    Rosenbaum, Janet E

    2012-02-01

    The 2011 attempted assassination of a US representative renewed the national gun control debate. Gun advocates claim mass-casualty events are mitigated and deterred with three policies: (a) permissive gun laws, (b) widespread gun ownership, (c) and encouragement of armed civilians who can intercept shooters. They cite Switzerland and Israel as exemplars. We evaluate these claims with analysis of International Crime Victimization Survey (ICVS) data and translation of laws and original source material. Swiss and Israeli laws limit firearm ownership and require permit renewal one to four times annually. ICVS analysis finds the United States has more firearms per capita and per household than either country. Switzerland and Israel curtail off-duty soldiers' firearm access to prevent firearm deaths. Suicide among soldiers decreased by 40 per cent after the Israeli army's 2006 reforms. Compared with the United States, Switzerland and Israel have lower gun ownership and stricter gun laws, and their policies discourage personal gun ownership.

  2. Evolution of rotating star clusters at the inelastic-collision stage. II. Dynamics of a disk of gas and stars

    International Nuclear Information System (INIS)

    Romanova, M.M.

    1985-01-01

    The dynamics of a gas--star disk embedded in a dense, mildly oblate (flattening epsilon-c or approx. =0.2--0.3 the stable disk will survive for at least half the cluster evolution time. The possibility of a thin disk of stars existing inside a dense star cluster is considered. For small epsilon-c and for disk member stars having > or approx. =0.04 the mass of the cluster members, collisions between cluster and disk stars will have no effect on the disk evolution prior to instability

  3. Staged membrane oxidation reactor system

    Science.gov (United States)

    Repasky, John Michael; Carolan, Michael Francis; Stein, VanEric Edward; Chen, Christopher Ming-Poh

    2012-09-11

    Ion transport membrane oxidation system comprising (a) two or more membrane oxidation stages, each stage comprising a reactant zone, an oxidant zone, one or more ion transport membranes separating the reactant zone from the oxidant zone, a reactant gas inlet region, a reactant gas outlet region, an oxidant gas inlet region, and an oxidant gas outlet region; (b) an interstage reactant gas flow path disposed between each pair of membrane oxidation stages and adapted to place the reactant gas outlet region of a first stage of the pair in flow communication with the reactant gas inlet region of a second stage of the pair; and (c) one or more reactant interstage feed gas lines, each line being in flow communication with any interstage reactant gas flow path or with the reactant zone of any membrane oxidation stage receiving interstage reactant gas.

  4. Augment-type two stage accelerator

    International Nuclear Information System (INIS)

    Ogino, Mutsuo; Azuma, Kingo.

    1995-01-01

    When a flying body accelerated by a gas gun at a first stage enters into an augment rail passing through an introduction tube, an ignition capacitor for initial plasmas is turned ON to apply a voltage between the augment rails. Subsequently, the accelerating gas present behind the flying body is formed into plasmas by a laser, to flow electric current from one of the inner augment rails → plasma armature → the other of the inner augment rails, and additionally accelerate the flying body by Lorentz force formed in this case. Since the plasmas are maintained in a state of higher density than the plasmas obtained by using all of the augment rails, the ignition capacitor for initial plasmas in switched to a power source. As a result, it is possible to flow the maximum current before the plasmas expand, and a large accelerating force and a high magnetic flux density are attained, to improve acceleration performance of the flying body. (N.H.)

  5. Gun possession among American youth: a discovery-based approach to understand gun violence.

    Science.gov (United States)

    Ruggles, Kelly V; Rajan, Sonali

    2014-01-01

    To apply discovery-based computational methods to nationally representative data from the Centers for Disease Control and Preventions' Youth Risk Behavior Surveillance System to better understand and visualize the behavioral factors associated with gun possession among adolescent youth. Our study uncovered the multidimensional nature of gun possession across nearly five million unique data points over a ten year period (2001-2011). Specifically, we automated odds ratio calculations for 55 risk behaviors to assemble a comprehensive table of associations for every behavior combination. Downstream analyses included the hierarchical clustering of risk behaviors based on their association "fingerprint" to 1) visualize and assess which behaviors frequently co-occur and 2) evaluate which risk behaviors are consistently found to be associated with gun possession. From these analyses, we identified more than 40 behavioral factors, including heroin use, using snuff on school property, having been injured in a fight, and having been a victim of sexual violence, that have and continue to be strongly associated with gun possession. Additionally, we identified six behavioral clusters based on association similarities: 1) physical activity and nutrition; 2) disordered eating, suicide and sexual violence; 3) weapon carrying and physical safety; 4) alcohol, marijuana and cigarette use; 5) drug use on school property and 6) overall drug use. Use of computational methodologies identified multiple risk behaviors, beyond more commonly discussed indicators of poor mental health, that are associated with gun possession among youth. Implications for prevention efforts and future interdisciplinary work applying computational methods to behavioral science data are described.

  6. Instantaneous current and field structure of a gun-driven spheromak for two gun polarities

    Science.gov (United States)

    Woodruff, S.; Nagata, M.

    2002-12-01

    The instantaneous plasma structure of the SPHEX spheromak is determined here by numerically processing data from insertable Rogowski and magnetic field probes. Data is presented and compared for two modes of gun operation: with the central electrode biased positively and negatively. It is found that while the mean-, or even instantaneous-, field structure would give the impression of a roughly axisymmetric spheromak, the instantaneous current structure does not. Hundred per cent variations in J measured at the magnetic axis can be explained by the rotation of a current filament that has a width equal to half of the radius of the flux-conserving first wall. In positive gun operation, current leaves the filament in the confinement region leading to high wall current there. In negative gun operation, wall current remains low as all injected current returns to the gun through the plasma. The plasma, in either instance, is strongly asymmetric. We discuss evidence for the existence of the current filament in other gun-driven spheromaks and coaxial plasma thrusters.

  7. Field Test Kit for Gun Residue Detection

    Energy Technology Data Exchange (ETDEWEB)

    WALKER, PAMELA K.; RODACY, PHILIP J.

    2002-01-01

    One of the major needs of the law enforcement field is a product that quickly, accurately, and inexpensively identifies whether a person has recently fired a gun--even if the suspect has attempted to wash the traces of gunpowder off. The Field Test Kit for Gunshot Residue Identification based on Sandia National Laboratories technology works with a wide variety of handguns and other weaponry using gunpowder. There are several organic chemicals in small arms propellants such as nitrocellulose, nitroglycerine, dinitrotoluene, and nitrites left behind after the firing of a gun that result from the incomplete combustion of the gunpowder. Sandia has developed a colorimetric shooter identification kit for in situ detection of gunshot residue (GSR) from a suspect. The test kit is the first of its kind and is small, inexpensive, and easily transported by individual law enforcement personnel requiring minimal training for effective use. It will provide immediate information identifying gunshot residue.

  8. Electrical parameters of projectile stun guns.

    Science.gov (United States)

    McDaniel, Wayne C; Benwell, Andrew; Kovaleski, Scott

    2009-01-01

    Projectile stun guns have been developed as less-lethal devices that law enforcement officers can use to control potentially violent subjects, as an alternative to using firearms. These devices apply high voltage, low amperage, pulsatile electric shocks to the subject, which causes involuntary skeletal muscle contraction and renders the subject unable to further resist. In field use of these devices, the electric shock is often applied to the thorax, which raises the issue of cardiac safety of these devices. An important determinant of the cardiac safety of these devices is their electrical output. Here the outputs of three commercially available projectile stun guns were evaluated with a resistive load and in a human-sized animal model (a 72 kg pig).

  9. Area source electron gun uniformity analysis

    Science.gov (United States)

    Qiu, YaFeng; Chang, BenKang; Sun, LianJun; Zhang, JunJu; Gao, YouTang; Fu, RongGuo

    2008-02-01

    Fluorescence screen of Image intensifier is the key part to imaging quality of micro light and ultraviolet Image intensifier. To research the performance testing and analysis of Fluorescence screen seems more important in China. The research will help to understand the performance of Fluorescence screen, know where improvement should be made and then a best performance entire tube will be achieved. This article will do the theory analysis to part of testing instrument, area source electron gun's uniformity. Electron gun consists of taper tantalum filament, vacuum environment and axial symmetry high pressure static field. The uniformity of hot electron emission of filament has been analyzed. Upon that, this article will specially analyze the uniformity of electron in the effective area after they go through the axial symmetry high pressure static field and get accelerated.

  10. 46 CFR 160.031-4 - Equipment for shoulder gun type line-throwing appliance.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Equipment for shoulder gun type line-throwing appliance... Appliance, Shoulder Gun Type (and Equipment) § 160.031-4 Equipment for shoulder gun type line-throwing... the gun. The line canister shall be secured by clamps or brackets below the barrel of the gun. (c) One...

  11. Magnetic guns with cylindrical permanent magnets

    Czech Academy of Sciences Publication Activity Database

    Vokoun, David; Beleggia, M.; Heller, Luděk

    2012-01-01

    Roč. 324, č. 9 (2012), s. 1715-1719 ISSN 0304-8853 R&D Projects: GA ČR(CZ) GAP107/11/0391; GA AV ČR IAA100100920 Institutional research plan: CEZ:AV0Z10100520 Keywords : permanent magnet * cylindrical magnet * Earnshaw's theorem * magnet ic gun * magnet ostatic interaction Subject RIV: BM - Solid Matter Physics ; Magnet ism Impact factor: 1.826, year: 2012 http://www.sciencedirect.com/science/article/pii/S0304885311008997

  12. Analysis of a Rail Gun Plasma Accelerator

    Science.gov (United States)

    1982-04-01

    similar, at least superficially, to ball lightning . This observation prompted a review of ball lightning phenomena to determine if the mechanisms...responsible for the propagation of ball lightning might be relevant for rail gun arcs. Unfortunately, due to the rare and unpredictable occurrence...of ball lightning , there is little experimental data available. The "data" which does exist consists of descriptions, or photographs at best, of

  13. Gun Laws and Crime: An Empirical Assessment

    OpenAIRE

    Matti Viren

    2012-01-01

    This paper deals with the effect of gun laws on crime. Several empirical analyses are carried to investigate the relationship between five different crime rates and alternative law variables. The tests are based on cross-section data from US sates. Three different law variables are used in the analysis, together with a set of control variables for income, poverty, unemployment and ethnic background of the population. Empirical analysis does not lend support to the notion that crime laws would...

  14. Advanced Technology for Naval Gun Tubes

    Science.gov (United States)

    1971-02-01

    Principal Engineer, Materials Technology, TRW Eo.uipment Group, TRW, Inc., 23555 Euclid Avenue. Cleve- land. Ohio 44117, Mr, Karl H, Meyer , Ordnance...barrels by the Army during World War II. The centri- fugal casting technique requires special facilities that are useful for no other purpose. Many...laboratory tests as well as scale - model gun-ammunition systems to permit, at reasonable cost, a correlation of the factors as well as the

  15. THE IMPROVEMENT AND APPLICATION OF EI-GUN (ELECTRICAL INSEMINATION GUN FOR ARTIFICIAL INSEMINATION (AI USING GOAT FRESH SEMEN

    Directory of Open Access Journals (Sweden)

    Mirsa Ita Dewi

    2017-03-01

    Full Text Available Electrical Insemination Gun (EI-GUN was a tool for Artificial Insemination (AI using fresh semen with an electric control system. The research objective was to produced EI-GUN for AI using fresh semen on small ruminants (goat. The research was conducted from March to June 2015. The process of EI-GUN creation implemented in Design and Prototype Laboratory and Aero Modeling Research Laboratory at Engineering Faculty, University of Brawijaya (UB. Testing tools EI-GUN on goat was conducted in the Sumber Sekar Laboratory, Animal Husbandry Faculty, UB.  The methods of research were literature study, tool specification determination, designing EI-GUN, running test, semen evaluation passed EI-GUN and application on Goat. EI-GUN has seven important parts, which supports each other in this operating system. Those parts consist of stylet, servo, system controlled, insemination pump, connecting rod, battery, and holder. EI-GUN work system sucked the semen into insemination pump as much as 5 ml, and release the semen 0.25 ml appropriate standard of AI. It was applicable for 20 times AI. The results showed that the cell motility of spermatozoa ≥ 70% were still in ranging of Indonesian National Standard (SNI.   Keywords: artificial insemination, EI-GUN, fresh semen.

  16. The Development of the Linac Coherent Light Source RF Gun

    International Nuclear Information System (INIS)

    Dowell, D

    2008-01-01

    The Linac Coherent Light Source (LCLS) is the first x-ray laser user facility based upon a free electron laser (FEL) requiring extraordinary beam quality to saturate at 1.5 angstroms within a 100 meter undulator.[1] This new type of light source is using the last kilometer of the three kilometer linac at SLAC to accelerate the beam to an energy as high as 13.6 GeV and required a new electron gun and injector to produce a very bright beam for acceleration. At the outset of the project it was recognized that existing RF guns had the potential to produce the desired beam but none had demonstrated it. Therefore a new RF gun or at least the modification of an existing gun was necessary. The parameters listed in Table 1 illustrate the unique characteristics of LCLS which drive the requirements for the electron gun as given in Table 2. The gun beam quality needs to accommodate emittance growth as the beam is travels through approximately one kilometer of linac and two bunch compressors before reaching the undulator. These beam requirements were demonstrated during the recent commissioning runs of the LCLS injector and linac [2] due to the successful design, fabrication, testing and operation of the LCLS gun. The goal of this paper is to relate the technical background of how the gun was able to achieve and in some cases exceed these requirements by understanding and correcting the deficiencies of the prototype s-band RF photocathode gun, the BNL/SLAC/UCLA Gun III. This paper begins with a brief history and technical description of Gun III and the Gun Test Facility (GTF) at SLAC, and studies of the gun's RF and emittance compensation solenoid. The work at the GTF identified the gun and solenoid deficiencies, and helped to define the specifications for the LCLS gun. Section 1.1.5 describes the modeling used to compute and correct the gun RF fields and Section 1.1.6 describes the use of these fields in the electron beam simulations. The magnetic design and measurements of

  17. HMX based enhanced energy LOVA gun propellant.

    Science.gov (United States)

    Sanghavi, R R; Kamale, P J; Shaikh, M A R; Shelar, S D; Kumar, K Sunil; Singh, Amarjit

    2007-05-08

    Efforts to develop gun propellants with low vulnerability have recently been focused on enhancing the energy with a further improvement in its sensitivity characteristics. These propellants not only prevent catastrophic disasters due to unplanned initiation of currently used gun propellants (based on nitrate esters) but also realize enhanced energy levels to increase the muzzle velocity of the projectiles. Now, in order to replace nitroglycerine, which is highly sensitive to friction and impact, nitramines meet the requirements as they offer superior energy due to positive heat of formation, typical stoichiometry with higher decomposition temperatures and also owing to negative oxygen balance are less sensitive than stoichiometrically balanced NG. RDX has been widely reported for use in LOVA propellant. In this paper we have made an effort to present the work on scantily reported nitramine HMX based LOVA gun propellant while incorporating energetic plasticizer glycidyl azide polymer to enhance the energy level. HMX is known to be thermally stable at higher temperature than RDX and also proved to be less vulnerable to small scale shaped charge jet attack as its decomposition temperature is 270 degrees C. HMX also offers improved impulse due to its superior heat of formation (+17 kcal/mol) as compared to RDX (+14 kcal/mol). It has also been reported that a break point will not appear until 35,000 psi for propellant comprising of 5 microm HMX. Since no work has been reported in open literature regarding replacement of RDX by HMX, the present studies were carried out.

  18. Beam-Based Procedures for RF Guns

    CERN Document Server

    Krasilnikov, Mikhail; Grabosch, H J; Hartrott, Michael; Hui Han, Jang; Miltchev, Velizar; Oppelt, Anne; Petrosyan, Bagrat; Staykov, Lazar; Stephan, Frank

    2005-01-01

    A wide range of rf photo injector parameters has to be optimized in order to achieve an electron source performance as required for linac based high gain FELs. Some of the machine parameters can not be precisely controlled by direct measurements, whereas the tolerance on them is extremely tight. Therefore, this should be met with beam-based techniques. Procedures for beam-based alignment (BBA) of the laser on the photo cathode as well as solenoid alignment have been developed. They were applied at the Photo Injector Test facility at DESY Zeuthen (PITZ) and at the photo injector of the VUV-FEL at DESY Hamburg. A field balance of the accelerating mode in the 1 ½ cell gun cavity is one of the key beam dynamics issues of the rf gun. Since no direct field measurement in the half and full cell of the cavity is available for the PITZ gun, a beam-based technique to determine the field balance has been proposed. A beam-based rf phase monitoring procedure has been developed as well.

  19. Experimental Studies of Electrothermal Plasma Gun

    International Nuclear Information System (INIS)

    Diab, F.B.A.

    2013-01-01

    The aim of the present work is to study the capillary plasma discharge dynamics and characteristics. The capillary plasma device is a new technology for producing high density plasma after ablating the capillary wall using a pulsed electric power. An Electrothermal Plasma Gun (ETG) is composed of a capillary discharge tube made of Teflon operated with simple RLC circuit. The device called Electrothermal Gun (ETG) which is composed of 4 capacitors (70 μF, 10 kV, 1.28 μH) connected in parallel to a plasma source by means of one high power supply. The gun was operated in open air at discharge energies between 35 J - 3.5 kJ according to charging voltage. The work presented in this thesis covers the following items, 1- Measurements of the basic parameters and characterizations of the pretest results of the electrical circuits and capillary plasma discharge using Rogowski coil, voltage probe and Photomultiplier. 2- Material processing including (physics of the surface modifications, the morphology of the surface by using Scanning Electron Microscope (SEM) at different conditions, compositions of the materials by using X-ray Fluorescence (XRF), Micro hardness test and material particle deposition.

  20. Altitude, gun ownership, rural areas, and suicide.

    Science.gov (United States)

    Kim, Namkug; Mickelson, Jennie B; Brenner, Barry E; Haws, Charlotte A; Yurgelun-Todd, Deborah A; Renshaw, Perry F

    2011-01-01

    The authors recently observed a correlation between state altitude and suicide rate in the United States, which could be explained by higher rates of gun ownership and lower population density in the intermountain West. The present study evaluated the relationship between mean county and state altitude in the United States and total age-adjusted suicide rates, firearm-related suicide rates, and non-firearm-related suicide rates. The authors hypothesized that altitude would be significantly associated with suicide rate. Elevation data were calculated with an approximate spatial resolution of 0.5 km, using zonal statistics on data sets compiled from the National Geospatial-Intelligence Agency and the National Aeronautics and Space Administration. Suicide and population density data were obtained through the Centers for Disease Control and Prevention (CDC) WONDER database. Gun ownership data were obtained through the CDC's Behavioral Risk Factor Surveillance System. A significant positive correlation was observed between age-adjusted suicide rate and county elevation (r=0.51). Firearm (r=0.41) and non-firearm suicide rates (r=0.32) were also positively correlated with mean county elevation. When altitude, gun ownership, and population density are considered as predictor variables for suicide rates on a state basis, altitude appears to be a significant independent risk factor. This association may be related to the effects of metabolic stress associated with mild hypoxia in individuals with mood disorders.

  1. Diagnostics Beamline for the SRF Gun Project

    CERN Document Server

    Kamps, T; Goldammer, K; Krämer, Dietrich; Kuske, P; Kuszynski, J; Lipka, D; Marhauser, F; Quast, T; Richter, R

    2005-01-01

    A superconducting rf photo electron injector (SRF gun) is currently under construction by a collaboration between BESSY, DESY, FZR and MBI. The project aims at the design and setup of an CW SRF gun including a diagnostics beamline for the ELBE FEL and to address R&D issues on low emittance injectors for future light sources such as the BESSY FEL. Of critical importance for the injector performance is the control of the electron beam parameters. For this reason a compact diagnostics beamline is under development serving a multitude of operation settings ranging from low-charge (77pC), low-emittance (1 pi mm mrad) mode to high-charge (2.5nC) operation of the gun. For these operation modes beam dynamics simulations are resulting in boundary conditions for the beam instrumentation. Proven and mature technology is projected wherever possible, for example for current and beam position monitoring. The layout of the beam profile and emittance measurement systems is described. For the bunch length, which varies be...

  2. Goods for Guns--the use of a gun buyback as an injury prevention/community education tool.

    Science.gov (United States)

    McGuire, Margaret; Manno, Mariann; Rook, Allison; Maranda, Louise; Renaud, Elizabeth; DeRoss, Anthony; Hirsh, Michael

    2011-11-01

    US children aged between 5 years and 14 years have a rate of gun-related homicide 17 times higher and a rate of gun-related suicide and unintentional firearm injury 10 times higher than other developed countries. Gun buyback programs have been criticized as ineffective interventions in decreasing violence. The Injury Free Coalition for Kids-Worcester (IFCK-W) Goods for Guns buyback is a multipronged approach to address these concerns and to reduce the number of firearms in the community. The IFCK-W buyback program is funded by corporate sponsors, grants, and individual donations. Citizens are instructed to transport guns, ammunition, and weapons safely to police headquarters on two Saturdays in December. Participants are guaranteed anonymity by the District Attorney's office and receive gift certificates for operable guns. Trained volunteers administer an anonymous survey to willing participants. Individuals who disclose having unsafely stored guns remaining at home receive educational counseling and trigger locks. Guns and ammunition are destroyed at a later time in a gun crushing ceremony. Since 2002, 1,861 guns (444 rifle/shotgun, 738 pistol/revolver, and 679 automatic/semiautomatic) have been collected at a cost of $99,250 (average, $53/gun). Seven hundred ten people have surrendered firearms, 534 surveys have been administered, and ≈ 75 trigger locks have been distributed per year. IFCK-W Goods for Guns is a relatively inexpensive injury prevention model program that removes unwanted firearms from homes, raises community awareness about gun safety, and provides high-risk individuals with trigger locks and educational counseling.

  3. Pioneer and late stage tropical rainforest tree species (French Guiana) growing under common conditions differ in leaf gas exchange regulation, carbon isotope discrimination and leaf water potential.

    Science.gov (United States)

    Huc, R; Ferhi, A; Guehl, J M

    1994-09-01

    Leaf gas exchange rates, predawn Ψ wp and daily minimum Ψ wm leaf water potentials were measured during a wet-to-dry season transition in pioneer (Jacaranda copaia, Goupia glabra andCarapa guianensis) and late stage rainforest tree species (Dicorynia guianensis andEperua falcata) growing in common conditions in artificial stands in French Guiana. Carbon isotope discrimination (Δ) was assessed by measuring the stable carbon isotope composition of the cellulose fraction of wood cores. The Δ values were 2.7‰ higher in the pioneer species than in the late stage species. The calculated time integratedC i values derived from the Δ values averaged 281 μmol mol -1 in the pioneers and 240 μmol mol -1 in the late stage species. The corresponding time-integrated values of intrinsinc water-use efficiency [ratio CO 2 assimilation rate (A)/leaf conductance (g)] ranged from 37 to 47 mmol mol -1 in the pioneers and the values were 64 and 74 mmol mol -1 for the two late stage species. The high Δ values were associated-at least inJ. copaia-with high maximumg values and with high plant intrinsinc specific hydraulic conductance [C≔g/(Ψ wm -Ψ wp ], which could reflect a high competitive ability for water and nutrient uptake in the absence of soil drought in the pioneers. A further clear discriminating trait of the pioneer species was the very sensitive stomatal response to drought in the soil, which might be associated with a high vulnerability to cavitation in these species. From a methodological point of view, the results show the relevance of Δ for distinguishing ecophysiological functional types among rainforest trees.

  4. Status and future prospects of SRF gun developments

    International Nuclear Information System (INIS)

    Teichert, Jochen

    2006-01-01

    While the concepts of DC and normal-conducting photo-injectors are well proofed, the SRF gun development still possesses a high risk. Challenges are the thermal and contaminant isolation needed between the cathode and superconducting cavity, the choice of the right photocathode and its life time, the difficulty of coupling high-average power into the gun, and beam excitation of higher order cavity modes. But in combination with SRF linacs, the SRF guns are the best solution for high current and CW operation. Thus, several R and D projects of SRF gun have been launched. The talk will give an overview of the history and progress of the SRF gun development. In more detail the technical concept, performance, and status of the Rossendorf superconducting RF gun project, a collaboration of BESSY, DESY, MBI and FZR, will be presented. (author)

  5. Spheromak experiment using separate guns for formation and sustainment

    International Nuclear Information System (INIS)

    Brown, M.R.; Martin, A.

    1996-01-01

    An experiment is described that incorporates the use of separate magnetized plasma guns for formation and sustainment of a spheromak. It is shown that energy coupling efficiency approaches unity if the gun and spheromak are of comparable size. A large gun should be able to operate at lower current and therefore lower voltage. In addition, it is expected that a gun matched to the size of the spheromak will cause less perturbation to the equilibrium. It is proposed to use a smaller gun for spheromak formation and a large, efficient gun for sustainment. The theoretical basis for the experiment is developed, and the details of the experiment are described. A prediction of the equilibrium magnetic flux surfaces using the EFIT code is presented. 28 refs., 3 figs., 1 tab

  6. Understanding the formative stage of technological innovation system development: The case of natural gas as an automotive fuel

    International Nuclear Information System (INIS)

    Suurs, Roald A.A.; Hekkert, Marko P.; Kieboom, Sander; Smits, Ruud E.H.M.

    2010-01-01

    This study contributes to insights into mechanisms that influence the successes and failures of emerging energy technologies. It is assumed that for an emerging technology to fruitfully develop, it should be fostered by a Technological Innovation System (TIS), which is the network of actors, institutions and technologies in which it is embedded. For an emerging technology a TIS has yet to be built up. This research focuses on the dynamics of this build-up process by mapping the development of seven key activities: so-called system functions. The main contribution revolves around the notion of cumulative causation, or the phenomenon that the build-up of a TIS accelerates due to system functions reinforcing each other over time. As an empirical basis, an analysis is provided of the historical development of the TIS around automotive natural gas technology in the Netherlands (1970-2007). The results show that this TIS undergoes a gradual build-up in the 1970s, followed by a breakdown in the 1980s and, again, a build-up from 2000 to 2007. It is shown that underlying these trends are different forms of cumulative causation, here called motors of innovation. The study provides strategic insights for practitioners that aspire to support such motors of innovation.

  7. Revised theory of Pierce-type electron guns

    International Nuclear Information System (INIS)

    Sar-El, H.Z.

    1982-01-01

    Attempts to date to obtain the shape of the beam forming electrodes of various Pierce-type electron guns are briefly discussed with emphasis on the many discrepansis in the results of previous works. A revised theory of Pierce-type electron guns is proposed. The shapes of the beam-forming electrodes for all known configurations of Pierce guns were computed on the basis of the proposed theory. (orig.)

  8. Continuity and Change in the American Gun Debate

    OpenAIRE

    Zimring, Franklin

    2001-01-01

    My paper traces the debates about firearms control over the three decades since I became involved in gun research in the late 1960s. The circumstances of public discourse about guns in the late 1960s were rich in sentiment and almost completely lacking in empirical data. Questions of firearms control were only episodically important at the national level, and the administration of federal gun laws was of minuscule importance prior to 1968.

  9. Controllability analysis and testing of a novel magnetorheological absorber for field gun recoil mitigation

    Science.gov (United States)

    Ouyang, Qing; Zheng, Jiajia; Li, Zhaochun; Hu, Ming; Wang, Jiong

    2016-11-01

    This paper aims to analyze the effects of combined working coils of magnetorheological (MR) absorber on the shock mitigation performance and verify the controllability of MR absorber as applied in the recoil system of a field gun. A physical scale model of the field gun is established and a long-stroke MR recoil absorber with four-stage parallel electromagnetic coils is designed to apply separate current to each stage and generate variable magnetic field distribution in the annular flow channel. Based on dynamic analysis and firing stability conditions of the field gun, ideal recoil force-stroke profiles of MR absorber at different limiting firing angles are obtained. The experimental studies are carried out on an impact test rig under different combinations of current loading: conventional unified control mode, separate control mode and timing control mode. The fullness degree index (FDI) is defined as the quantitative evaluation criterion of the controllability of MR absorber during the whole recoil motion. The results show that the force-stroke profile of the novel MR absorber can approach the ideal curve within 25 degrees of the limiting firing angle through judicious exploitation of the adjustable rheological properties of MR fluid.

  10. Heat Transfer and Flow on the First Stage Blade Tip of a Power Generation Gas Turbine. Part 1; Experimental Results

    Science.gov (United States)

    Bunker, Ronald S.; Bailey, Jeremy C.; Ameri, Ali A.

    1999-01-01

    A combined computational and experimental study has been performed to investigate the detailed distribution of convective heat transfer coefficients on the first stage blade tip surface for a geometry typical of large power generation turbines(>100MW). This paper is concerned with the design and execution of the experimental portion of the study. A stationary blade cascade experiment has been run consisting of three airfoils, the center airfoil having a variable tip gap clearance. The airfoil models the aerodynamic tip section of a high pressure turbine blade with inlet Mach number of 0.30, exit Mach number of 0.75, pressure ratio of 1.45, exit Reynolds number based on axial chord of 2.57 x 10(exp 6), and total turning of about 110 degrees. A hue detection based liquid crystal method is used to obtain the detailed heat transfer coefficient distribution on the blade tip surface for flat, smooth tip surfaces with both sharp and rounded edges. The cascade inlet turbulence intensity level took on values of either 5% or 9%. The cascade also models the casing recess in the shroud surface ahead of the blade. Experimental results are shown for the pressure distribution measurements on the airfoil near the tip gap, on the blade tip surface, and on the opposite shroud surface. Tip surface heat transfer coefficient distributions are shown for sharp-edge and rounded-edge tip geometries at each of the inlet turbulence intensity levels.

  11. Electron-beam pumping of visible and ultraviolet gas lasers

    International Nuclear Information System (INIS)

    Bradley, L.P.

    1975-01-01

    Several techniques for using direct electron-pumping of gas lasers are reviewed. The primary objective is to categorize pump geometries and to give guidelines for gun selection and pulser design. Examples and application of pump technology are given

  12. Quantification of regional early stage gas exchange changes using hyperpolarized {sup 129}Xe MRI in a rat model of radiation-induced lung injury

    Energy Technology Data Exchange (ETDEWEB)

    Doganay, Ozkan, E-mail: ozkan.doganay@oncology.ox.ac.uk [Department of Medical Biophysics, Western University, London, Ontario N6A5C1 (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A5C1 (Canada); Department of Oncology, University of Oxford, Old Road Campus Research Building, Roosevelt Drive, Oxford OX3 7DQ (United Kingdom); Stirrat, Elaine [Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, 555 University Avenue, Toronto, Ontario M5G1X8 (Canada); McKenzie, Charles [Department of Medical Biophysics, Western University, London, Ontario N6A5C1 (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A5C1 (Canada); Schulte, Rolf F. [General Electric Global Research, Munich 85748 (Germany); Santyr, Giles E. [Department of Medical Biophysics, Western University, London, Ontario N6A5C1 (Canada); Imaging Research Laboratories, Robarts Research Institute, London, Ontario N6A5C1 (Canada); Peter Gilgan Centre for Research and Learning, The Hospital for Sick Children, 555 University Avenue, Toronto, Ontario M5G1X8 (Canada); Department of Medical Biophysics, University of Toronto, Toronto, Ontario M5G1L7 (Canada)

    2016-05-15

    Purpose: To assess the feasibility of hyperpolarized (HP) {sup 129}Xe MRI for detection of early stage radiation-induced lung injury (RILI) in a rat model involving unilateral irradiation by assessing differences in gas exchange dynamics between irradiated and unirradiated lungs. Methods: The dynamics of gas exchange between alveolar air space and pulmonary tissue (PT), PT and red blood cells (RBCs) was measured using single-shot spiral iterative decomposition of water and fat with echo asymmetry and least-squares estimation images of the right and left lungs of two age-matched cohorts of Sprague Dawley rats. The first cohort (n = 5) received 18 Gy irradiation to the right lung using a {sup 60}Co source and the second cohort (n = 5) was not irradiated and served as the healthy control. Both groups were imaged two weeks following irradiation when radiation pneumonitis (RP) was expected to be present. The gas exchange data were fit to a theoretical gas exchange model to extract measurements of pulmonary tissue thickness (L{sub PT}) and relative blood volume (V{sub RBC}) from each of the right and left lungs of both cohorts. Following imaging, lung specimens were retrieved and percent tissue area (PTA) was assessed histologically to confirm RP and correlate with MRI measurements. Results: Statistically significant differences in L{sub PT} and V{sub RBC} were observed between the irradiated and non-irradiated cohorts. In particular, L{sub PT} of the right and left lungs was increased approximately 8.2% and 5.0% respectively in the irradiated cohort. Additionally, V{sub RBC} of the right and left lungs was decreased approximately 36.1% and 11.7% respectively for the irradiated cohort compared to the non-irradiated cohort. PTA measurements in both right and left lungs were increased in the irradiated group compared to the non-irradiated cohort for both the left (P < 0.05) and right lungs (P < 0.01) confirming the presence of RP. PTA measurements also correlated with the

  13. A flow cryostat for cooling of eight independent pipe guns

    DEFF Research Database (Denmark)

    Sørensen, H.; Hansen, J.E.; Sass, B.

    1991-01-01

    A flow cryostat allowing independent cooling of eight pipe guns in a multishot deuterium pellet injector is described. The pipe guns are placed symmetrically around the flow cryostat and with a liquid helium consumption of 4-5 l/h the cooling is sufficient for simultaneous formation of eight...... pellets at 8-9 K with a diameter of 2.1 mm containing up to 8 x 10(20) atoms/pellet. The thermal interaction between the eight pipe guns is sufficiently low to allow successive firing of the guns with time intervals of up to 1 s....

  14. Brief use of a specific gun in a violent game does not affect attitudes towards that gun

    OpenAIRE

    Hilgard, Joseph; Engelhardt, Christopher R.; Bartholow, Bruce D.

    2016-01-01

    Although much attention has been paid to the question of whether violent video games increase aggressive behaviour, little attention has been paid to how such games might encourage antecedents of gun violence. In this study, we examined how product placement, the attractive in-game presentation of certain real-world firearm brands, might encourage gun ownership, a necessary antecedent of gun violence. We sought to study how the virtual portrayal of a real-world firearm (the Bushmaster AR-15) ...

  15. Analysis of honeybush tea (Cyclopia spp.) volatiles by comprehensive two-dimensional gas chromatography using a single-stage thermal modulator.

    Science.gov (United States)

    Ntlhokwe, Gaalebalwe; Tredoux, Andreas G J; Górecki, Tadeusz; Edwards, Matthew; Vestner, Jochen; Muller, Magdalena; Erasmus, Lené; Joubert, Elizabeth; Christel Cronje, J; de Villiers, André

    2017-07-01

    The applicability of comprehensive two-dimensional gas chromatography (GC×GC) using a single-stage thermal modulator was explored for the analysis of honeybush tea (Cyclopia spp.) volatile compounds. Headspace solid phase micro-extraction (HS-SPME) was used in combination with GC×GC separation on a non-polar × polar column set with flame ionisation (FID) detection for the analysis of fermented Cyclopia maculata, Cyclopia subternata and Cyclopia genistoides tea infusions of a single harvest season. Method optimisation entailed evaluation of the effects of several experimental parameters on the performance of the modulator, the choice of columns in both dimensions, as well as the HS-SPME extraction fibre. Eighty-four volatile compounds were identified by co-injection of reference standards. Principal component analysis (PCA) showed clear differentiation between the species based on their volatile profiles. Due to the highly reproducible separations obtained using the single-stage thermal modulator, multivariate data analysis was simplified. The results demonstrate both the complexity of honeybush volatile profiles and the potential of GC×GC separation in combination with suitable data analysis techniques for the investigation of the relationship between sensory properties and volatile composition of these products. The developed method therefore offers a fast and inexpensive methodology for the profiling of honeybush tea volatiles. Graphical abstract Surface plot obtained for the GC×GC-FID analysis of honeybush tea volatiles.

  16. Solid-state pulse modulator using Marx generator for a medical linac electron-gun

    Science.gov (United States)

    Lim, Heuijin; Hyeok Jeong, Dong; Lee, Manwoo; Lee, Mujin; Yi, Jungyu; Yang, Kwangmo; Ro, Sung Chae

    2016-04-01

    A medical linac is used for the cancer treatment and consists of an accelerating column, waveguide components, a magnetron, an electron-gun, a pulse modulator, and an irradiation system. The pulse modulator based on hydrogen thyratron-switched pulse-forming network is commonly used in linac. As the improvement of the high power semiconductors in switching speed, voltage rating, and current rating, an insulated gate bipolar transistor has become the more popular device used for pulsed power systems. We propose a solid-state pulse modulator to generator high voltage by multi-stacked storage-switch stages based on the Marx generator. The advantage of our modulator comes from the use of two semiconductors to control charging and discharging of the storage capacitor at each stage and it allows to generate the pulse with various amplitudes, widths, and shapes. In addition, a gate driver for two semiconductors is designed to reduce the control channels and to protect the circuits. It is developed for providing the pulsed power to a medical linac electron-gun that requires 25 kV and 1 A as the first application. In order to improve the power efficiency and achieve the compactness modulator, a capacitor charging power supply, a Marx pulse generator, and an electron-gun heater isolated transformer are constructed and integrated. This technology is also being developed to extend the high power pulsed system with > 1 MW and also other applications such as a plasma immersed ion implantation and a micro pulse electrostatic precipitator which especially require variable pulse shape and high repetition rate > 1 kHz. The paper describes the design features and the construction of this solid-state pulse modulator. Also shown are the performance results into the linac electron-gun.

  17. Solid-state pulse modulator using Marx generator for a medical linac electron-gun

    International Nuclear Information System (INIS)

    Lim, Heuijin; Jeong, Dong Hyeok; Lee, Manwoo; Lee, Mujin; Yi, Jungyu; Yang, Kwangmo; Ro, Sung Chae

    2016-01-01

    A medical linac is used for the cancer treatment and consists of an accelerating column, waveguide components, a magnetron, an electron-gun, a pulse modulator, and an irradiation system. The pulse modulator based on hydrogen thyratron-switched pulse-forming network is commonly used in linac. As the improvement of the high power semiconductors in switching speed, voltage rating, and current rating, an insulated gate bipolar transistor has become the more popular device used for pulsed power systems. We propose a solid-state pulse modulator to generator high voltage by multi-stacked storage-switch stages based on the Marx generator. The advantage of our modulator comes from the use of two semiconductors to control charging and discharging of the storage capacitor at each stage and it allows to generate the pulse with various amplitudes, widths, and shapes. In addition, a gate driver for two semiconductors is designed to reduce the control channels and to protect the circuits. It is developed for providing the pulsed power to a medical linac electron-gun that requires 25 kV and 1 A as the first application. In order to improve the power efficiency and achieve the compactness modulator, a capacitor charging power supply, a Marx pulse generator, and an electron-gun heater isolated transformer are constructed and integrated. This technology is also being developed to extend the high power pulsed system with > 1 MW and also other applications such as a plasma immersed ion implantation and a micro pulse electrostatic precipitator which especially require variable pulse shape and high repetition rate > 1 kHz. The paper describes the design features and the construction of this solid-state pulse modulator. Also shown are the performance results into the linac electron-gun

  18. Low Emittance Guns for the ILC Polarized Electron Beam

    International Nuclear Information System (INIS)

    Clendenin, J. E.; Brachmann, A.; Ioakeimidi, K.; Kirby, R. E.; Maruyama, T.; Miller, R. H.; Wang, J. W.; Zhou, F.

    2007-01-01

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressed by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of ≥200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while ≥500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns

  19. Low Emittance Guns for the ILC Polarized Electron Beam

    International Nuclear Information System (INIS)

    Clendenin, J.E.; Brachmann, A.; Ioakeimidi, K.; Kirby, R.E.; Maruyama, T.; Miller, R.H.; Wang, J.W.; Zhou, F.; SLAC

    2006-01-01

    Polarized electron beams generated by DC guns are routinely available at several accelerators including JLAB, Mainz and SLAC. These guns operate with a cathode bias on the order of -100 kV. To minimize space charge effects, relatively long bunches are generated at the gun and then compressed longitudinally external to the gun just before and during initial acceleration. For linear colliders, this compression is accomplished using a combination of rf bunchers. For the basic design of the International Linear Collider (ILC), a 120 kV DC photocathode gun is used to produce a series of nanosecond bunches that are each compressed by two sub-harmonic bunchers (SHBs) followed by an L-band buncher and capture section. The longitudinal bunching process results in a significantly higher emittance than produced by the gun alone. While high-energy experiments using polarized beams are not generally sensitive to the source emittance, there are several benefits to a lower source emittance including a simpler more efficient injector system and a lower radiation load during transport especially at bends as at the damping ring. For the ILC, the SHBs could be eliminated if the voltage of the gun is raised sufficiently. Simulations using the General Particle Tracer (GPT) package indicate that a cathode bias voltage of (ge)200 kV should allow both SHBs to be operated at 433 or even 650 MHz, while (ge)500 kV would be required to eliminate the SHBs altogether. Simulations can be used to determine the minimum emittance possible if the injector is designed for a given increased voltage. A possible alternative to the DC gun is an rf gun. Emittance compensation, routinely used with rf guns, is discussed for higher-voltage DC guns

  20. Perancangan Sistem Kontrol PID Untuk Pengendali Sumbu Elevasi Gun Pada Turret-Gun Kaliber 20 Milimeter

    Directory of Open Access Journals (Sweden)

    Dimas Kunto Ariwibowo

    2017-01-01

    Full Text Available Pertahanan negara pada hakikatnya adalah segala upaya pertahanan yang bersifat semesta yang didasarkan pada kesadaran atas hak dan kewajiban warga negara serta keyakinan pada kekuatan sendiri dengan tujuan untuk menjaga dan melindungi kedaulatan negara, keutuhan wilayah NKRI dan keselamatan segenap bangsa. Salah satu alat pendukung pertahanan yaitu senjata laras panjang, Turret-Gun.  Adapun langkah-langkah yang dilakukan dalam merancang pengendali PID Turret-Gun kaliber 20mm ini diawali dengan studi literatur serta studi lapangan mengenai mekanisme dan parameter-parameter yang terdapat pada Turret-Gun pada sumbu elevasi. Setelah itu dilakukan perancangan transmisi dan sistem kontrol Turret-Gun untuk dievaluasi grafik responnya yang akan digunakan sebagai acuan untuk merancang pengendali PID yang sesuai. Selanjutnya pengendali PID yang telah dirancang lalu disimulasikan, sehingga menghasilkan grafik respon yang sesuai dengan kriteria yang dibutuhkan. Hasil yang telah didapatkan dari penelitian ini adalah konstanta PID yang direkomendasikan untuk , , dan secara berturut-turut adalah sebesar 23061.024, 37820.07 dan 3515.4 yang menghasilkan transient response dengan nilai overshoot sebesar 19.9 % , steady state error sebesar 0 % serta settling time sebesar 0.935 detik. Hasil analisa kestabilan untuk sistem kontrol dengan konstanta PID tersebut menunjukkan bahwa sistem kontrol telah stabil, baik menggunakan metode Root Locus maupun metode Routh-Hurwitz.

  1. Action Alters Object Identification: Wielding a Gun Increases the Bias to See Guns

    Science.gov (United States)

    Witt, Jessica K.; Brockmole, James R.

    2012-01-01

    Stereotypes, expectations, and emotions influence an observer's ability to detect and categorize objects as guns. In light of recent work in action-perception interactions, however, there is another unexplored factor that may be critical: The action choices available to the perceiver. In five experiments, participants determined whether another…

  2. Analysis of conjugated heat transfer, in transient state of the first stage of a gas turbine; Analisis de transferencia de calor conjugada, en estado transitorio, de la primera etapa de una turbina de gas

    Energy Technology Data Exchange (ETDEWEB)

    Campos Amezcua, Alfonso; Mazur C, Zdzislaw [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Gallegos Munoz, Armando [Facultad de Ingenieria Mecanica, Electrica y Electronica (FIMEE), Universidad de Guanajuato, Guanajuato (Mexico)

    2007-11-15

    This article presents an analysis of conjugated heat transfer in the first stage of movable blades during the starting of a gas turbine, covering a period of 1,012 seconds. The developed computer model is in 3D and uses as initial and border conditions typical starting curves for stack gases, the cooling air and the angular velocity of the blades. As a result of the numerical predictions, the temperature distributions in stack gases, the trowel of the blade and the cooling air are included, doing emphasis in the results obtained in the solid (body of the blade), since these are used for thermo-mechanical stress analysis and later estimation of the blade residual life. [Spanish] Este articulo presenta un analisis de transferencia de calor conjugada en la primera etapa de alabes moviles, durante el arranque de una turbina de gas, cubriendo un periodo de 1.012 segundos. El modelo computacional desarrollado es en tres dimensiones y utiliza como condiciones iniciales y de frontera curvas de arranque tipicas para los gases de combustion, el aire de enfriamiento y la velocidad angular de los alabes. Como resultado de las predicciones numericas, se incluyen las distribuciones de temperatura en los gases de combustion, la paleta del alabe y el aire de enfriamiento, haciendo enfasis en los resultados obtenidos en el solido (cuerpo del alabe), ya que estos se utilizan para analisis de esfuerzos termomecanicos y posterior estimacion de vida residual del alabe.

  3. Gun buyback programs: a venue to eliminate unwanted guns in the community.

    Science.gov (United States)

    Violano, Pina; Driscoll, Cassandra; Chaudhary, Neil K; Schuster, Kevin M; Davis, Kimberly A; Borer, Esther; Winters, Jane K; Hirsh, Michael P

    2014-09-01

    The United States has a high rate of death due to firearms, and gun buyback programs may mitigate these high death rates. Understanding the demographics, motivation, and geographic region of participants may improve program efficacy. Three Injury Free Coalition for Kids gun buyback programs, in collaboration with the local police, were studied: Phoenix, Arizona; Worcester, Massachusetts; and New Haven, Connecticut. Participants were defined as those who relinquished a firearm. A self-administered, anonymous, paper survey elicited information from participants regarding demographic data, formal training on the use of the firearm, how the firearm was acquired, potential child access, knowledge of others injured by a firearm, whether the firearm was stored unlocked, factors motivating the surrender of the firearm, and other factors. Survey results were entered into a composite database and analyzed for differences in location, race, sex, and other factors. Participants (n = 301) were predominantly male (73.5%), white (80.9%), and older than 55 years (59.0%). They lived an average of 19.0 miles from the event by zip codes and had an average median household income of $65,731. More than half (54.5%) did not purchase the firearm, acquiring it through inheritance, gift, or random find. Most (74.8%) had previous firearms training and were relinquishing for safety reasons (68.3%). Those relinquishing firearms for safety reasons were less likely to have purchased the firearm (odds ratio [OR], 2.46, p gun lock (OR, 0.15; p gun-wielding criminal acts were burglarized from the home of legal gun owners that had failed to secure them properly. The gun buyback program is solely one prong of a multipronged approach in reducing firearm-based interpersonal violence. Additional research is necessary to determine effective methods to target individuals who would have the greatest impact on gun violence if they relinquished their weapons. Through the forging of relationships and

  4. Testing a GaAs cathode in SRF gun

    International Nuclear Information System (INIS)

    Wang, E.; Kewisch, J.; Ben-Zvi, I.; Burrill, A.; Rao, T.; Wu, Q.; Holmes, D.

    2011-01-01

    RF electron guns with a strained superlattice GaAs cathode are expected to generate polarized electron beams of higher brightness and lower emittance than do DC guns, due to their higher field gradient at the cathode's surface and lower cathode temperature. We plan to install a bulk GaAs:Cs in a SRF gun to evaluate the performance of both the gun and the cathode in this environment. The status of this project is: In our 1.3 GHz 1/2 cell SRF gun, the vacuum can be maintained at nearly 10 -12 Torr because of cryo-pumping at 2K. With conventional activation of bulk GaAs, we obtained a QE of 10% at 532 nm, with lifetime of more than 3 days in the preparation chamber and have shown that it can survive in transport from the preparation chamber to the gun. The beam line has been assembled and we are exploring the best conditions for baking the cathode under vacuum. We report here the progress of our test of the GaAs cathode in the SRF gun. Future particle accelerators, such as eRHIC and the ILC require high-brightness, high-current polarized electrons. Strained superlattice GaAs:Cs has been shown to be an efficient cathode for producing polarized electrons. Activation of GaAs with Cs,O(F) lowers the electron affinity and makes it energetically possible for all the electrons, excited into the conduction band that drift or diffuse to the emission surface, to escape into the vacuum. Presently, all operating polarized electron sources, such as the CEBAF, are DC guns. In these devices, the excellent ultra-high vacuum extends the lifetime of the cathode. However, the low field gradient on the photocathode's emission surface of the DC guns limits the beam quality. The higher accelerating gradients, possible in the RF guns, generate a far better beam. Until recently, most RF guns operated at room temperature, limiting the vacuum to ∼10 -9 Torr. This destroys the GaAs's NEA surface. The SRF guns combine the excellent vacuum conditions of DC guns and the high accelerating

  5. Smart gun technology requirements preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, D.R.; Brandt, D.J.; Tweet, K.D.

    1995-05-01

    Goal of the Smart Gun Technology project is to eliminate the capability of an unauthorized user from firing a law enforcement officer`s firearm by implementing user-recognizing-and-authorizing surety technologies. This project is funded by the National Institute of Justice. This document reports the projects first objective: to find and document the requirements for a user-recognizing-and-authorizing firearm technology that law enforcement officers will value. This report details the problem of firearm takeaways in law enforcement, the methodology used to develop the law enforcement officers` requirements, and the requirements themselves.

  6. Electron gun simulation with CST PARTICLE STUDIO

    International Nuclear Information System (INIS)

    Spachmann, Holger; Becker, Ulrich

    2006-01-01

    This paper introduces CST PARTICLE STUDIO TM , a specialist tool for the fast and accurate design and analysis of 3D electron guns. The new software is based on the multi-purpose electromagnetic solvers of the CST STUDIO family and incorporates their powerful modelling capabilities as well as successful algorithms of the MAFIA-TS simulators. The underlying theory of the PBA based field solvers and the used tracking technique is presented and some examples of application demonstrate the current status of the software

  7. The evolution of gas price: gas assessment and perspectives; The evolution of gas price on the American, Asian and European markets; Assessment of the organised gas market; Assessment of gas market opening; Gas price: the point of view of consumers and providers; Tariff, the formula which cannot be found: a new stage in an endless history; The diversity of the world gas industry: the Mediterranean situation on prices

    International Nuclear Information System (INIS)

    Malherbe, Herve; Corbeau, Anne-Sophie; Lu, Long; Maire, Jacques; Verdier, Catherine; Bros, Thierry; Nyouki, Evariste; Astruc, Pierre; Katz, Richard; Jamme, Dominique; Rosier, Philippe; Salanson, Damien; Saniez, Thierry; Moraleda, Pedro; Le Gourrierec, M.

    2012-01-01

    After a brief introduction, this document contains the various contributions and interventions during round tables dealing with the evolution of gas price on American, Asian and European markets, an assessment of the organised gas market (model, references, members, and so on), an assessment of market gas opening, the point of view of consumers and providers on gas price. Then three articles address the issue of gas pricing in France, the developments of gas industry in the world (consumptions, production, perspectives for LNG) and the Mediterranean situation with respect to gas prices (trends and challenges)

  8. Gun possession among American youth: a discovery-based approach to understand gun violence.

    Directory of Open Access Journals (Sweden)

    Kelly V Ruggles

    Full Text Available OBJECTIVE: To apply discovery-based computational methods to nationally representative data from the Centers for Disease Control and Preventions' Youth Risk Behavior Surveillance System to better understand and visualize the behavioral factors associated with gun possession among adolescent youth. RESULTS: Our study uncovered the multidimensional nature of gun possession across nearly five million unique data points over a ten year period (2001-2011. Specifically, we automated odds ratio calculations for 55 risk behaviors to assemble a comprehensive table of associations for every behavior combination. Downstream analyses included the hierarchical clustering of risk behaviors based on their association "fingerprint" to 1 visualize and assess which behaviors frequently co-occur and 2 evaluate which risk behaviors are consistently found to be associated with gun possession. From these analyses, we identified more than 40 behavioral factors, including heroin use, using snuff on school property, having been injured in a fight, and having been a victim of sexual violence, that have and continue to be strongly associated with gun possession. Additionally, we identified six behavioral clusters based on association similarities: 1 physical activity and nutrition; 2 disordered eating, suicide and sexual violence; 3 weapon carrying and physical safety; 4 alcohol, marijuana and cigarette use; 5 drug use on school property and 6 overall drug use. CONCLUSIONS: Use of computational methodologies identified multiple risk behaviors, beyond more commonly discussed indicators of poor mental health, that are associated with gun possession among youth. Implications for prevention efforts and future interdisciplinary work applying computational methods to behavioral science data are described.

  9. Gun Possession among American Youth: A Discovery-Based Approach to Understand Gun Violence

    Science.gov (United States)

    Ruggles, Kelly V.; Rajan, Sonali

    2014-01-01

    Objective To apply discovery-based computational methods to nationally representative data from the Centers for Disease Control and Preventions’ Youth Risk Behavior Surveillance System to better understand and visualize the behavioral factors associated with gun possession among adolescent youth. Results Our study uncovered the multidimensional nature of gun possession across nearly five million unique data points over a ten year period (2001–2011). Specifically, we automated odds ratio calculations for 55 risk behaviors to assemble a comprehensive table of associations for every behavior combination. Downstream analyses included the hierarchical clustering of risk behaviors based on their association “fingerprint” to 1) visualize and assess which behaviors frequently co-occur and 2) evaluate which risk behaviors are consistently found to be associated with gun possession. From these analyses, we identified more than 40 behavioral factors, including heroin use, using snuff on school property, having been injured in a fight, and having been a victim of sexual violence, that have and continue to be strongly associated with gun possession. Additionally, we identified six behavioral clusters based on association similarities: 1) physical activity and nutrition; 2) disordered eating, suicide and sexual violence; 3) weapon carrying and physical safety; 4) alcohol, marijuana and cigarette use; 5) drug use on school property and 6) overall drug use. Conclusions Use of computational methodologies identified multiple risk behaviors, beyond more commonly discussed indicators of poor mental health, that are associated with gun possession among youth. Implications for prevention efforts and future interdisciplinary work applying computational methods to behavioral science data are described. PMID:25372864

  10. Guns and Crime: Protection versus Peril. Firearm Facts.

    Science.gov (United States)

    Duker, Laurie, Ed.

    Many Americans, terrified of violent crime, attempt to protect themselves by owning guns. However, statistics provided in this brief fact sheet reveal that people who choose to have a gun easily available are in fact putting their families and friends into greater danger since far more homicides occur during domestic arguments than during…

  11. Study and realization of an electron gun at low energy

    International Nuclear Information System (INIS)

    Camus, P.

    1977-01-01

    This work presents the theoretical concepts and experimental design of an electron gun. This gun is working in the weak energy range and the focus position is independant of electron energy measurements and analysis methods of the electron beam are described [fr

  12. A 3 GHz photoelectron gun for high beam intensity

    CERN Document Server

    Bossart, Rudolf; Dehler, M; Godot, J C

    1996-01-01

    For the Compact Linear Collider Test Facility (CTF) at CERN a new rf gun with a laser driven photocathode is under construction. The new rf gun will replace the present 11/2 cell gun and will consist of 21/2 cells accelerating the beam to a momentum of 7.0 MeV/c with an electric field strength of 100 MV/m. The strong space-charge forces at low beam energy caused by the high charge density of the electron bunches are contained by radial and longitudinal rf focusing in the gun. The rf gun under construction has been optimized by MAFIA beam simulations for an injector assembly comprising a second accelerating rf structure and an intermediate solenoid magnet correcting the beam divergence of the 21/2 cell gun. The beam loading of the rf gun, by a train of 48 bunches with 21 nC charge each, causes a strong energy decay accompanied by an increase of the flight time for the bunches with lower energy. These effects can be corrected by slightly shifting the acceleration frequency of the gun. The experimental results...

  13. Characterization of an Electron Gun for Hollow Electron Beam Collimation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Siqi [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Stancari, Giulio [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2012-08-01

    Hollow electron beam collimation (HEBC) is a new technique developed to complement conventional beam collimation system to remove beam halo in a controlled fashion. We study the characteristics of the electron gun that produces the hollow electron beam. Cathode yield and beam profile measurements are used to extract information on gun performance. Results of characteristic measurements are presented.

  14. Guns and Fear: A One-Way Street?

    Science.gov (United States)

    Hauser, Will; Kleck, Gary

    2013-01-01

    Surveys show that more than one half of gun owners report owning their firearm for self-protection. Although research has examined the effect of fear of crime on gun ownership, the issue of reciprocity and temporal order has been largely ignored. Furthermore, the effect of firearm acquisition and relinquishment on fear has not been evaluated…

  15. Gun Possession among Massachusetts Batterer Intervention Program Enrollees

    Science.gov (United States)

    Rothman, Emily F.; Johnson, Renee M.; Hemenway, David

    2006-01-01

    Batterers with access to firearms present a serious lethal threat to their partners. The purpose of this exploratory study is to estimate the prevalence of and risk markers for gun possession among Massachusetts men enrolled in batterer intervention programs. The authors found that 1.8% of the men reported having a gun in or around their home.…

  16. Taking Aim at Gun Violence: Rebuilding Community Education & Employment Pathways

    Science.gov (United States)

    Bryant, Rhonda

    2013-01-01

    In January 2013, President Obama released a plan for protecting children and communities by reducing gun violence. This plan has generated serious debate from both sides of the issue. The ensuing conversations about how to solve the issue of gun violence have been volatile. The President's plan includes reforms to close loopholes on background…

  17. Everyday Engineering: What Makes a Squirt Gun Squirt?

    Science.gov (United States)

    Moyer, Richard; Everett, Susan

    2009-01-01

    You may not think of engineering and squirt guns in the same sentence. However, like many examples of engineering design, the squirt gun pump mechanism is uncomplicated, yet elegant, and very inexpensive to manufacture. The design is widely used because of its simplicity and low cost. With only a few moving parts, it is able to deliver a stream of…

  18. Normative Considerations in the Aftermath of Gun Violence in Schools

    Science.gov (United States)

    Gereluk, Dianne T.; Donlevy, J. Kent; Thompson, Merlin B.

    2015-01-01

    Gun violence in American and Canadian schools is an ongoing tragedy that goes substantially beyond its roots in the interlocking emotional and behavioral issues of mental health and bullying. In light of the need for effective policy development, Dianne T. Gereluk, J. Kent Donlevy, and Merlin B. Thompson examine gun violence in schools from…

  19. Grip-pattern recognition: Applied to a smart gun

    NARCIS (Netherlands)

    Shang, X.

    2008-01-01

    In our work the verification performance of a biometric recognition system based on grip patterns, as part of a smart gun for use by the police ocers, has been investigated. The biometric features are extracted from a two-dimensional pattern of the pressure, exerted on the grip of a gun by the hand

  20. The gun control system of the IFUSP microtron

    International Nuclear Information System (INIS)

    Malafronte, A.A.; Takahashi, J.; Bonini, A.L.; Martins, M.N.

    1997-01-01

    A thermionic gun control system has been developed for the IFUSP microtron. The control system, which is composed of a dedicated microcomputer, A/D converter, grid pulser, filament and grid power supplies, is kept at a high voltage potential. The gun parameters are handled through a PC computer at ground potential via fiber-optic link. (orig.)

  1. Modelling multi-ion plasma gun simulations of Tokamak disruptions

    International Nuclear Information System (INIS)

    Ehst, D.A.

    1995-08-01

    The effect of impurity ions in plasma gun ablation tests of various targets is considered. Inclusion of reasonable amounts of impurity (∼10%) is adequate to explain observed energy transmission and erosion measurements. The gun tests and the computer code calculations are relevant to the parameter range expected for major disruptions on large tokamaks

  2. Accidental Bolt Gun Injury to Femur - A Case Report.

    Science.gov (United States)

    Kattimani, Ravi Prasad; Shetty, Sanath; Mirza, Humayun

    2016-01-01

    Bolt gun or slaughterer's guns are used in meat industry for "humane killing" of animals. Injuries caused by bolt gun are rare, reported exclusively from central European countries. We report a case of 28 year old male, who accidentally shot himself with a bolt gun to his right thigh. A 28 years old male presented to our Accident and Emergency department after accidental injury to his right thigh with bolt gun. He had an entry wound measuring 2 cm in length and 1 cm in breadth over anterior aspect of lower one third of thigh at lower and sustained Grade II compound fracture of right femur shaft at distal one third. The wound was treated with multiple debridements, negative pressure wound therapy and intravenous antibiotics based on culture and sensitivity. Bolt gun or slaughterer's guns are weapons used in meat industry for slaughtering animals. Wounds inflicted by bolt guns have specific morphological feature, distinctive from wounds made by other kinds of hand firearms. Most of the time wound will be infected at presentation. Lesions caused by these weapons are likely to have a more serious character than is to be expected from the size of the entrance wound. The mainstay of treatment is liberal wound exploration, multiple debridement's and intra venous antibiotics based on culture reports to treat infection and prevent morbidity.

  3. Gun Access and Safety Practices among Older Adults

    Directory of Open Access Journals (Sweden)

    Hillary D. Lum

    2016-01-01

    Full Text Available Background. Given high rates of gun ownership among older adults, geriatric providers can assess firearm safety practices using a “5 Ls” approach: Locked; Loaded; Little children; feeling Low; and Learned owner. This study describes gun access and the “5 Ls” among US older adults. Methods. Data on the “5 Ls” from the Second Injury Control and Risk Survey (ICARIS-2, a national telephone survey conducted by the Centers for Disease Control and Prevention, were analyzed. Weighted variables were used to generate national estimates regarding prevalence of gun ownership and associated gun safety among older adults (≥55 years. Results. Of 2939 older adults, 39% (95% CI 37%–42% reported ≥1 gun stored at home. Among those with guns at home, 21% (95% CI 18–24% stored guns loaded and unlocked; 9.2% (95% CI 6.6–12% had ≥1 child in household; 5.1% (95% CI 3.5–6.8% reported past-year suicidal ideation and 3.6% (95% CI 2.1–5.2% reported history of a suicide attempt; and 55% (95% CI 51–59% stated that ≥1 adult had attended firearm safety workshop. Conclusion. Some older adults may be at elevated risk of firearm injury because of storage practices, suicidal thoughts, or limited safety training. Future work should assess effective approaches to reduce the risk of gun-related injuries among older adults.

  4. Cold cathode electron guns in the LASL high power short-pulse CO2 laser program

    International Nuclear Information System (INIS)

    Singer, S.; Ladish, J.S.; Nutter, M.J.

    1975-01-01

    The Electron Beam Controlled Discharge CO 2 Laser is now firmly established as the only high power short pulse laser amplifier that has been demonstrated to have scaling capabilities to large apertures and energies much greater than 100 J. These devices require a beam of energetic electrons to control the gas discharge that produces the required population inversion. Until recently, the electron source was usually a thermionic emitter, even for rather large lasers, whose heater requirements dwarfed the pulsed energies associated with the transient operation of the laser. With the advent of reliable cold-cathode electron guns, the operation of these lasers has been greatly simplified. At LASL, there are four electron beam controlled laser systems which are in operation, under construction, or in design: the 1 kJ system, now operational; the 2.5 kJ system; the 10 kJ system; and the 100 kJ system. Only the first uses thermionic-emitter electron guns; the remainder use or will use cold cathode sources. The operation of the 200 x 35 cm 2 two sided cold cathode electron gun used in the 2.5 kJ laser system and to be used in the 10 kJ laser is described

  5. Therminoic gun control system for the CEBAF injector

    International Nuclear Information System (INIS)

    Pico, R.; Diamond, B.; Fugitt, J.; Bork, R.

    1989-01-01

    The injector for the CEBAF accelerator must produce a high-quality electron beam to meet the overall accelerator specifications. A Hermosa electron gun with a 2 mm-diameter cathode and a control aperture has been chosen as the electron source. This must be controlled over a wide range of operating conditions to meet the beam specifications and to provide flexibility for accelerator commissioning. The gun is controlled using Computer Automated Measurement and Control (CAMAC IEEE-583) technology. The system employs the CAMAC-based control architecture developed at CEBAF. The control system has been tested, and early operating data on the electron gun and the injector beam transport system has been obtained. This system also allows gun parameters to be stored at the operator location, without paralyzing operation. This paper describes the use of this computer system in the control of the CEBAF electron gun. 2 refs., 6 figs., 1 tab

  6. High Brightness Injectors Based On Photocathode DC Gun

    International Nuclear Information System (INIS)

    B. Yunn

    2001-01-01

    Sample results of new injector design method based on a photocathode dc gun are presented, based on other work analytically proving the validity of the emittance compensation scheme for the case even when beam bunching is involved. We have designed several new injectors appropriate for different bunch charge ranges accordingly. Excellent beam quality produced by these injectors clearly shows that a photocathode dc gun can compete with a rf gun on an equal footing as the source of an electron beam for the bunch charge ranging up to 2 nano Coulomb (nC). This work therefore elevates a dc gun based injector to the preferred choice for many ongoing high brightness accelerator projects considering the proven operational stability and high average power capability of the dc gun

  7. An rf modulated electron gun pulser for linacs

    International Nuclear Information System (INIS)

    Legg, R.; Hartline, R.

    1991-01-01

    Present linac injector designs often make use of sub-harmonic prebuncher cavities to properly bunch the electron beam before injection into a buncher and subsequent accelerating cavities. This paper proposes an rf modulated thermionic gun which would allow the sub-harmonic buncher to be eliminated from the injector. The performance parameters for the proposed gun are 120 kV operating voltage, macropulse duration-single pulse mode 2 nsec, multiple pulse mode 100 nsec, rf modularing frequency 500 MHz, charge per micropulse 0.4 nC, macropulse repetition frequency 10 Hz (max). The gun pulser uses a grid modulated planar triode to drive the gun cathode. The grid driver takes advantage of recently developed modular CATV rf drivers, high performance solid state pulser devices, and high-frequency fiber optic transmitters for telecommunications. Design details are presented with associated SPICE runs simulating operation of the gun

  8. Guns, Mental Illness, and the Law: Introduction to This Issue.

    Science.gov (United States)

    Swanson, Jeffrey W; Felthous, Alan R

    2015-06-01

    Firearm violence is a top-tier public health problem in the U.S., killing 33,563 and injuring an additional 81,396 people in 2012 (Centers for Disease Control and Prevention, CDC, ). Given constitutional protection and the cultural entrenchment of private gun ownership in the U.S., it is likely that guns will remain widely accessible--and largely unrestricted--for the foreseeable future. Therefore, most policies and laws intended to reduce firearm violence focus selectively on preventing "dangerous people" from having access to guns. That is a formidable challenge. How do we think productively about guns and mental illness in this context, and about the role of law in lessening the toll of gun violence? Copyright © 2015 John Wiley & Sons, Ltd.

  9. Gas swelling behaviour at different stages in Li4Ti5O12/LiNi1/3Co1/3Mn1/3O2 pouch cells

    Science.gov (United States)

    Liu, Wei; Liu, Haohan; Wang, Qian; Zhang, Jian; Xia, Baojia; Min, Guoquan

    2017-11-01

    Gas swelling behaviour is a major drawback of batteries that are based on Li4Ti5O12 anode materials and hinders their application. In this article, the morphology and electronic structure changes of Li4Ti5O12 electrodes at ageing and cycling stages are investigated using scanning electron microscopy, X-ray absorption near-edge structure and X-ray photoelectron spectroscopy. A simple method that uses an air bag to collect the generated gases was conducted and the gases were then characterised by gas chromatography/mass spectrometry. The results indicate that the charge transformation of Ti ions would aggravate the gas swelling behaviour. The solid electrolyte interphase (SEI) films form on the surface of the Li4Ti5O12 particles and become thicker with increasing charge state. The gas components change significantly during the ageing and cycling, indicating the complexity of the gas swelling mechanism.

  10. Correlates of gun-carrying among adolescents in south Louisiana.

    Science.gov (United States)

    McNabb, S J; Farley, T A; Powell, K E; Rolka, H R; Horan, J M

    1996-01-01

    In the majority of episodes of fatal interpersonal violence, the weapon used is a firearm. Amid frequent reports of youths carrying weapons, including firearms, we conducted a case-control study to identify risk factors for being charged with gun-carrying and gun-carrying, per se, among adolescents in Jefferson Parish, Louisiana. Cases were defined as incidents of gun-carrying among adolescents juvenile court from January 1, 1992, through April 15, 1993. For each case, we randomly drew three age-, gender-, and school-matched control subjects from the enrollment rosters of the Jefferson Parish public schools and administered a questionnaire. The data set comprised 38 case subjects and 103 matched control subjects. Thirty (29%) control subjects reported gun-carrying. Both case subjects and gun-carrying control subjects reported self-defense (40%) as the main reason for gun-carrying. Most case subjects (25 [66%]) were African Americans, but only 8 (27%) gun-carrying and 27 (37%) non-gun-carrying control subjects were African Americans. Case subjects were significantly more likely than gun-carrying control subjects to report being African American (odds ratio [OR] = 5.3, 95% confidence intervals [CI] = 1.6, 17.5). In crude analyses, case subjects were more likely than non-gun-carrying control subjects to report adult-male unemployment among households with adult men, to foresee a likelihood to be shot in school, to have seen a shooting, to use marijuana, to watch television > 6 hours per day, and to be African American. After the effect estimates were adjusted in conditional logistic regression modeling, case subjects were more likely than non-gun-carrying control subjects to report adult-male unemployment among households with adult men, using marijuana, and watching television > 6 hours per day (OR = 8.6, 95% CI = 1.2, 61,2; OR = 11.7, 95% CI = 2, 70.2; and OR = 6.5, 95% CI = 0.8, 51.9, respectively). Gun-carrying control subjects were significantly more likely than

  11. Combined cycle simulator with gas turbine and steam turbine with one vaporization stage; Simulador de ciclo combinado con turbina de gas y de vapor con un nivel de vaporizacion

    Energy Technology Data Exchange (ETDEWEB)

    Del Valle Cardenas, B.; Lugo Leyte, R. [Universidad Autonoma Metropolitana, Depto de Ingenieria de Procesos e Hidraulica, Mexico, D. F. (Mexico); Toledo Velazquez, Miguel; Tolentino Eslava, G. [Seccion de Estudios de Posgrado e Investigacion, Laboratorio de Ingenieria Termica e Hidraulica Aplicada, ESIME-IPN-COFFA, Mexico, D. F. (Mexico)

    1998-12-31

    This paper shows the thermal analysis of a combined cycle with gas and steam turbines with one vaporization stage. The analysis is performed through a computer program, which allows the simulation of cycles with different operational conditions, obtaining this way a series of results that permits to know the way these cycles behave in effecting temperature and pressure changes; besides of being an excellent tool in thermodynamics for the user. The simulators were performed in Borland C++ and Builder C++ Versions 4.5 and 2.0 respectively, creating in this way a friendly ambient for the user. This tool offers the opportunity to all its users the ability to simulate combined cycles in a fast and easy way in order to obtain a wider understanding of its thermodynamic behavior. [Espanol] En el presente trabajo se muestra el analisis termico de un ciclo combinado con turbinas de gas y de vapor con un nivel de vaporizacion. El analisis se realiza a traves de un programa de computo, el cual permite simular los ciclos con diferentes condiciones de operacion, obteniendo con esto una serie de resultados que permiten conocer la forma en que trabajan estos ciclos al realizar cambios en temperaturas y presiones; ademas de que es una excelente herramienta para el usuario en termodinamica. Los simuladores fueron realizados en Borland C++ y Builder C++ Versiones 4.5 y 2.0 respectivamente, creandose asi un ambiente amigable para el usuario. Esta herramienta brinda la oportunidad a todos los usuarios de poder simular ciclos combinados de una manera rapida y sencilla con el fin de obtener una comprension mas amplia de su comportamiento termodinamico.

  12. The estimation of CO2 storage potential of gas-bearing shale complex at the early stage of reservoir characterization: the case of Baltic Basin (Poland).

    Science.gov (United States)

    Wójcicki, Adam; Jarosiński, Marek

    2017-04-01

    For the stage of shale gas production, like in the USA, prediction of the CO2 storage potential in shale reservoir can be performed by dynamic modeling. We have made an attempt to estimate this potential at an early stage of shale gas exploration in the Lower Paleozoic Baltic Basin, based on data from 3,800 m deep vertical well (without hydraulic fracking stimulation), supplemented with additional information from neighboring boreholes. Such an attempt makes a sense as a first guess forecast for company that explores a new basin. In our approach, the storage capacity is build by: (1) sorption potential of organic matter, (2) open pore space and (3) potential fracture space. the sequence. our estimation is done for 120 m long shale sequence including three shale intervals enriched with organic mater. Such an interval is possible to be fracked from a single horizontal borehole as known from hydraulic fracture treatment in the other boreholes in this region. The potential for adsorbed CO2 is determined from Langmuir isotherm parameters taken from laboratory measurements in case of both CH4 and CO2 adsorption, as well as shale density and volume. CO2 has approximately three times higher sorption capacity than methane to the organic matter contained in the Baltic Basin shales. Finally, due to low permeability of shale we adopt the common assumption for the USA shale basins that the CO2 will be able to reach effectively only 10% of theoretical total sorption volume. The pore space capacity was estimated by utilizing results of laboratory measurements of dynamic capacity for pores bigger than 10 nm. It is assumed for smaller pores adsorption prevails over free gas. Similarly to solution for sorption, we have assumed that only 10 % of the tight pore space will be reached by CO2. For fracture space we have considered separately natural (tectonic-origin) and technological (potentially produced by hydraulic fracturing treatment) fractures. From fracture density profile and

  13. Gun violence in Americans' social network during their lifetime.

    Science.gov (United States)

    Kalesan, Bindu; Weinberg, Janice; Galea, Sandro

    2016-12-01

    The overall burden of gun violence death and injury in the US is now well understood. However, no study has shown the extent to which gun violence is associated with the individual lives of Americans. We used fatal and non-fatal gun injury rates in 2013 from Centers for Disease Control and Prevention's Web-based Injury Statistics Query and Reporting System (WISQARS) and generally accepted estimates about the size of an American's social network to determine the likelihood that any given person will know someone in their personal social network who is a victim of gun violence during their lifetime. We derived estimates in the overall population and among racial/ethnic groups and by gun-injury intent. The likelihood of knowing a gun violence victim within any given personal network over a lifetime is 99.85% (99.8% to 99.9%). The likelihood among non-Hispanic white, black, Hispanic and other race Americans were 97.1%, 99.9%, 99.5% and 88.9% respectively. Nearly all Americans of all racial/ethnic groups are likely to know a victim of gun violence in their social network during their lifetime. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Experimental and theoretical investigations of a 17 GHz RF gun

    CERN Document Server

    Brown, W J; Kreischer, K E; Pedrozzi, M; Shapiro, M A; Temkin, R J

    1999-01-01

    We report on experimental and theoretical investigations of a 17 GHz RF photocathode electron gun. This is the first photocathode electron gun to operate at a frequency above 2.856 GHz. The 1.5 cell, pi mode, copper cavity was tested with 50 ns pulses from a 17.150 GHz klystron amplifier built by Haimson Research Corp. A Bragg filter was used at the RF gun to reduce the reflection of parasitic modes back into the klystron. Coupling hole theory in conjunction with cold test measurements was used to determine the field profile in the RF gun. The particle in cell code MAGIC as well as coupled envelope equations were used to simulate the beam dynamics in the RF gun. With power levels of 4 MW, the on axis electric field at the cathode exceeds 300 MV/m, corresponding to an average accelerating gradient of 200 MV/m over the first half cell of the gun. Breakdown was observed at power levels above 5 MW. Electron bunches were produced by 20 mu J, 1 ps UV laser pulses impinging on the RF gun copper photocathode and were...

  15. Law enforcement officers' opinions about gun locks: anchors on life jackets?

    OpenAIRE

    Coyne-Beasley, T; Johnson, R

    2001-01-01

    Objectives—One way law enforcement officers support firearm safety is by promoting the use of gun locks. This investigation examined law enforcement officers' willingness to use gun locks on their own guns, as well as their opinions regarding gun locks in general.

  16. Analysis of gun barrel rifling twist

    Science.gov (United States)

    Sun, Jia; Chen, Guangsong; Qian, Linfang; Liu, Taisu

    2017-05-01

    Aiming at the problem of gun barrel rifling twist, the constraint relation between rifling and projectile is investigated. The constraint model of rifling and projectile is established and the geometric relation between the twist and the motion of projectile is analyzed. Based on the constraint model, according to the rotating band that is fired, the stress and the motion law of the rotating band in bore are analyzed. The effects to rotating band (double rotating band or wide driving band) caused by different rifling (rib rifling, increasing rifling and combined rifling) are also investigated. The model is demonstrated by several examples. The results of numerical examples and the constraint mode show that the uncertainty factors will be brought in the increasing rifling and combined rifling during the projectile move in the bore. According to the amplitude and the strength of the twist acting on rotating band, the steady property of rotational motion of the projectile, the rib rifling is a better choose.

  17. Smart Gun Technology project. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, D.R.

    1996-05-01

    The goal of the Smart Gun Technology project is to eliminate the capability of an unauthorized user form firing a law officer`s firearm by implementing user-recognizing-and-authorizing (or {open_quotes}smart{close_quotes}) surety technologies. This project was funded by the National Institute of Justice. This report lists the findings and results of the project`s three primary objectives. First, to find and document the requirements for a smart firearm technology that law enforcement officers will value. Second, to investigate, evaluate, and prioritize technologies that meet the requirements for a law enforcement officer`s smart firearm. Third, to demonstrate and document the most promising technology`s usefulness in models of a smart firearm.

  18. Laser photo-cathode RF-gun

    International Nuclear Information System (INIS)

    Washio, Masakazu

    2006-01-01

    High quality beam generation project based on High-Tech Research Center Project, which has been approved by Ministry of Education, Culture, Sports, Science and Technology in 1999, has been conducted by advanced research institute for science and engineering, Waseda University. In the project, laser photo-cathode RF-gun has been selected for the high quality electron beam source. RF cavities with low dark current, which were made by diamond turning technique have been successfully manufactured. The low emittance electron beam was realized by choosing the modified laser injection technique. The obtained normalized emittance was about 3 mm mrad at 100 pC of electron charge. The soft X-ray beam generation with the energy of 370 eV, which is in the energy region of so-called 'water window', by inverse Compton scattering has been performed by the collision between IR laser and the low emittance electron beams. (author)

  19. Projectile Balloting Attributable to Gun Tube Curvature

    Directory of Open Access Journals (Sweden)

    Michael M. Chen

    2010-01-01

    Full Text Available Transverse motion of a projectile during launch is detrimental to firing accuracy, structural integrity, and/or on-board electronics performance of the projectile. One manifest contributing factor to the undesired motion is imperfect bore centerline straightness. This paper starts with the presentation of a deterministic barrel model that possesses both vertical and lateral deviations from centerline in accordance with measurement data, followed by a novel approach to simulating comprehensive barrel centerline variations for the investigation of projectile balloting^1 motions. A modern projectile was adopted for this study. In-bore projectile responses at various locations of the projectile while traveling through the simulated gun tubes were obtained. The balloting was evaluated in both time and frequency domains. Some statistical quantities and the significance were outlined.

  20. Summary, Working Group 1: Electron guns and injector designs

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; Bazarov, I.V.

    2006-01-01

    We summarize the proceedings of Working Group 1 of the 2005 Energy Recovery Linac (ERL) Workshop. The subject of this working group, the electron gun and injector design, is arguably the most critical part of the ERL as it determines the ultimate performance of this type of accelerators. Working Group 1 dealt with a variety of subjects: The technology of DC, normal-conducting RF and superconducting RF guns; beam dynamics in the gun and injector; the cathode and laser package; modeling and computational issues; magnetized beams and polarization. A short overview of these issues covered in the Working Group is presented in this paper

  1. Function of bunching segment in multi-cell RF gun

    International Nuclear Information System (INIS)

    Yang Xingfan; Xu Zhou Liu Xisan

    2001-01-01

    With a bunching segment and a shortened first cell, the 4 + 1/2 cell RF gun produced in CAEP has been proved experimentally to be effective in reducing electron back bombardment. The analysis of the electric field distribution and electron motion in bunching segment of multi-cell RF gun is presented. The electron capture efficiency and electron trajectory with different initial phase are calculated using Runge-Kutta method. The function of the bunching segment is discussed. The calculated parameters of the 4 + 1/2 cell RF gun agree well with the experimental results

  2. The properties of on-axis coupled structure RF gun

    CERN Document Server

    Oda, F; Nakayama, A; Koike, H; Tanabe, E

    2000-01-01

    Kawasaki Heavy Industries Ltd. (KHI) has developed the compact IR FEL device, which adopts a combination of a newly designed RF gun with a thermionic cathode and an alpha-magnet as an injector. The accelerating mode of the S-band RF gun is a pi/2 standing wave mode. The coupling cell is located on the beam axis, the so-called on-axis coupled structure (OCS). The cavity shape was designed by using electromagnetic field analytical codes. The OCS RF gun was manufactured and the electromagnetic properties were measured. The results show good agreement with the simulations.

  3. Commentary: evidence to guide gun violence prevention in America.

    Science.gov (United States)

    Webster, Daniel W

    2015-03-18

    Gun violence is a major threat to the public's health and safety in the United States. The articles in this volume's symposium on gun violence reveal the scope of the problem and new trends in mortality rates from gunfire. Leading scholars synthesize research evidence that demonstrates the ability of numerous policies and programs-each consistent with lessons learned from successful efforts to combat public health problems-to prevent gun violence. Each approach presents challenges to successful implementation. Future research should inform efforts to assess which approaches are most effective and how to implement evidence-based interventions most effectively.

  4. Note: Characteristic beam parameter for the line electron gun.

    Science.gov (United States)

    Iqbal, M; Islam, G U; Zhou, Z; Chi, Y

    2013-11-01

    We have optimized the beam parameters of line source electron gun using Stanford Linear Accelerator Centre electron beam trajectory program (EGUN), utilizing electrostatic focusing only. We measured minimum beam diameter as 0.5 mm that corresponds to power density of 68.9 kW/cm(2) at 13.5 mm in the post-anode region which is more than two-fold (33 kW/cm(2)), of the previously reported results. The gun was operated for the validation of the theoretical results and found in good agreement. The gun is now without any magnetic and electrostatic focusing thus much simpler and more powerful.

  5. Method of electron emission control in RF guns

    International Nuclear Information System (INIS)

    Khodak, I.V.; Kushnir, V.A.

    2001-01-01

    The electron emission control method for a RF gun is considered.According to the main idea of the method,the additional resonance system is created in a cathode region where the RF field strength could be varied using the external pulse equipment. The additional resonance system is composed of a coaxial cavity coupled with a RF gun cylindrical cavity via an axial hole. Computed results of radiofrequency and electrodynamic performances of such a two-cavity system and results of the RF gun model pilot study are presented in. Results of particle dynamics simulation are described

  6. Method of electron emission control in RF guns

    CERN Document Server

    Khodak, I V

    2001-01-01

    The electron emission control method for a RF gun is considered.According to the main idea of the method,the additional resonance system is created in a cathode region where the RF field strength could be varied using the external pulse equipment. The additional resonance system is composed of a coaxial cavity coupled with a RF gun cylindrical cavity via an axial hole. Computed results of radiofrequency and electrodynamic performances of such a two-cavity system and results of the RF gun model pilot study are presented in. Results of particle dynamics simulation are described.

  7. Design studies on high current and grid control electron gun

    International Nuclear Information System (INIS)

    Wang Jinnan; Lu Kun; Chi Yunlong; Zhou Zusheng

    2011-01-01

    Electron gun, the source of electrons, is a kind of ultrahigh vacuum device and plays an important role in different kind of accelerators. With the irradiation accelerator demands, describes the design studies on beam optics optimization. The simulation result shows that the beam current is above 5 A with cathode voltage of 80 kV and beam emittance, gun electric field and beam waist radius meet the accelerator needs. The electron gun manufactured and installed in the test stand, the conditioning and test will be done in the near future. (authors)

  8. Gun culture and symbolism among U.K. and U.S. women.

    Science.gov (United States)

    Cooke, C A; Puddifoot, J E

    2000-08-01

    The authors explored attitudes of young women in the United Kingdom (n = 108) and the United States (n = 91) toward (a) the possession and use of guns through the Attitude to Guns Scale (N. R. Branscombe, J. A. Weir, & P. Crosby, 1992) and (b) guns' perceived functional and symbolic significance through the Symbolic Nature of Guns Scale (C. A. Cooke & J. E. Puddifoot, 1997). There were significant differences in beliefs concerning the right to own a gun and the protective effect of guns but not in the perceived contribution of guns to crime. Although neither group strongly equated guns symbolically with power or control, the U.S. women were more likely to perceive guns as expressions of freedom or independence, and the U.K. women were more likely to view guns as expressions of danger and violence. The findings were contextualized by comparison with samples of male control participants of similar ages.

  9. Brief use of a specific gun in a violent game does not affect attitudes towards that gun.

    Science.gov (United States)

    Hilgard, Joseph; Engelhardt, Christopher R; Bartholow, Bruce D

    2016-11-01

    Although much attention has been paid to the question of whether violent video games increase aggressive behaviour, little attention has been paid to how such games might encourage antecedents of gun violence. In this study, we examined how product placement, the attractive in-game presentation of certain real-world firearm brands, might encourage gun ownership, a necessary antecedent of gun violence. We sought to study how the virtual portrayal of a real-world firearm (the Bushmaster AR-15) could influence players' attitudes towards the AR-15 specifically and gun ownership in general. College undergraduates ( N  = 176) played one of four modified video games in a 2 (gun: AR-15 or science-fiction control) × 2 (gun power: strong or weak) between-subjects design. Despite collecting many outcomes and examining many potential covariates and moderators, experimental assignment did little to influence outcomes of product evaluations or purchasing intentions with regard to the AR-15. Attitudes towards public policy and estimation of gun safety were also not influenced by experimental condition, although these might have been better tested by comparison against a no-violence control condition. By contrast, gender and political party had dramatic associations with all outcomes. We conclude that, if product placement shapes attitudes towards firearms, such effects will need to be studied with stronger manipulations or more sensitive measures.

  10. Brief use of a specific gun in a violent game does not affect attitudes towards that gun

    Science.gov (United States)

    Engelhardt, Christopher R.; Bartholow, Bruce D.

    2016-01-01

    Although much attention has been paid to the question of whether violent video games increase aggressive behaviour, little attention has been paid to how such games might encourage antecedents of gun violence. In this study, we examined how product placement, the attractive in-game presentation of certain real-world firearm brands, might encourage gun ownership, a necessary antecedent of gun violence. We sought to study how the virtual portrayal of a real-world firearm (the Bushmaster AR-15) could influence players' attitudes towards the AR-15 specifically and gun ownership in general. College undergraduates (N = 176) played one of four modified video games in a 2 (gun: AR-15 or science-fiction control) × 2 (gun power: strong or weak) between-subjects design. Despite collecting many outcomes and examining many potential covariates and moderators, experimental assignment did little to influence outcomes of product evaluations or purchasing intentions with regard to the AR-15. Attitudes towards public policy and estimation of gun safety were also not influenced by experimental condition, although these might have been better tested by comparison against a no-violence control condition. By contrast, gender and political party had dramatic associations with all outcomes. We conclude that, if product placement shapes attitudes towards firearms, such effects will need to be studied with stronger manipulations or more sensitive measures. PMID:28018611

  11. The Effect of Child Access Prevention Laws on Non-Fatal Gun Injuries

    OpenAIRE

    Jeff DeSimone; Sara Markowitz

    2005-01-01

    Many states have passed child access prevention (CAP) laws, which hold the gun owner responsible if a child gains access to a gun that is not securely stored. Previous CAP law research has focused exclusively on gun-related deaths even though most gun injuries are not fatal. We use annual hospital discharge data from 1988-2001 to investigate whether CAP laws decrease non-fatal gun injuries. Results from Poisson regressions that control for various hospital, county and state characteristics, i...

  12. The Transmission of Gun and Other Weapon-Involved Violence Within Social Networks

    OpenAIRE

    Tracy, Melissa; Braga, Anthony A.; Papachristos, Andrew V.

    2016-01-01

    Fatal and nonfatal injuries resulting from gun violence remain a persistent problem in the United States. The available research suggests that gun violence diffuses among people and across places through social relationships. Understanding the relationship between gun violence within social networks and individual gun violence risk is critical in preventing the spread of gun violence within populations. This systematic review examines the existing scientific evidence on the transmission of gu...

  13. Revisiting the Gun Ownership and Violence Link; a multi- level analysis of victimisation survey data.

    OpenAIRE

    van Kesteren, J.N.

    2014-01-01

    The link between gun ownership victimisation by violent crime remains one of the most contested issues in criminology. Some authors claim that high gun availability facilitates serious violence. Others claim that gun ownership prevents crime. This article revisits these issues using individual and aggregate data on gun ownership and victimisation from the ICVS. Analysis at country level shows that the level of hand gun ownership is positively related to serious violence but not for lesser ser...

  14. Evaluation of a single-stage consumable-free modulator for comprehensive two-dimensional gas chromatography: analysis of polychlorinated biphenyls, organochlorine pesticides and chlorobenzenes.

    Science.gov (United States)

    Muscalu, Alina M; Edwards, Matthew; Górecki, Tadeusz; Reiner, Eric J

    2015-04-24

    Comprehensive two-dimensional gas chromatography (GC×GC) has been rapidly growing in popularity. The GC×GC separation is performed by interfacing a modulator between two columns of different selectivities. The modulator periodically traps and then re-injects the analytes eluting from the first column into the second column. The most popular GC×GC systems require consumables such as liquid N2 for the trapping function of the modulator. Although these systems are very effective, their costs are a hindrance to more widespread use. A new, single-stage thermal modulator for GC×GC that requires no consumables has been developed and tested. The device traps analytes using a proprietary stainless steel capillary trap compressed between two ceramic cooling pads. Analytes are thermally desorbed from the trap into the second column via resistive heating. To evaluate this system, a routine accredited method for the analysis of polychlorinated biphenyls, organochlorine pesticides and chlorobenzenes was run using the new modulator and its performance was compared to that of an industry standard modulation system. Within-day repeatability (% RSD ranging from 2% to 13%), between-day reproducibility (% RSD from 3% to 15%), as well as between-trap reproducibility were assessed. The results are very encouraging as negligible shifts in retention times (% RSD from 0.3% to 0.6% in the 1st dimension and 0.8% to 2% in the 2nd dimension) were observed for both within-day and day-to-day comparisons of the studied samples (ANOVA, p=0.9893 for the sediment reference material compared), and the quantitative results were comparable. Routine analysis and quality control applications will benefit from the improved reproducibility as the variances in cold/hot jet flows and temperatures are eliminated. An overview of the device operation and the results from this study are summarized. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. A NEW THERMIONIC RF ELECTRON GUN FOR SYNCHROTRON LIGHT SOURCES

    Energy Technology Data Exchange (ETDEWEB)

    Kutsaev, Sergey; Agustsson, R.; Hartzell, J; Murokh, A.; Nassiri, A.; Savin, E.; Smirnov, A.V.; Smirnov, A. Yu; Sun, Y.; Verma, A; Waldschmidt, Geoff; Zholents, A.

    2017-06-02

    A thermionic RF gun is a compact and efficient source of electrons used in many practical applications. RadiaBeam Systems and the Advanced Photon Source at Argonne National Laboratory collaborate in developing of a reliable and robust thermionic RF gun for synchrotron light sources which would offer substantial improvements over existing thermionic RF guns and allow stable operation with up to 1A of beam peak current at a 100 Hz pulse repetition rate and a 1.5 μs RF pulse length. In this paper, we discuss the electromagnetic and engineering design of the cavity and report the progress towards high power tests of the cathode assembly of the new gun.

  16. Finite element analyses for RF photoinjector gun cavities

    International Nuclear Information System (INIS)

    Marhauser, F.

    2006-01-01

    This paper details electromagnetical, thermal and structural 3D Finite Element Analyses (FEA) for normal conducting RF photoinjector gun cavities. The simulation methods are described extensively. Achieved results are presented. (orig.)

  17. Spot-Welding Gun With Adjustable Pneumatic Spring

    Science.gov (United States)

    Burley, Richard K.

    1990-01-01

    Proposed spot-welding gun equipped with pneumatic spring, which could be bellows or piston and cylinder, exerts force independent of position along stroke. Applies accurate controlled force to joint welded, without precise positioning at critical position within stroke.

  18. Design and fabrication of a pulsed diode electron gun

    International Nuclear Information System (INIS)

    Mahadevan, S.; Gandhi, M.L.; Nandedkar, R.V.

    2003-01-01

    A pulsed diode electron gun has been designed, fabricated and tested and this will be used for the initial hot testing of the Plane Wave Transformer (PWT) linac. The gun is required to deliver 1 A at 70 kV which works out to a current of 500 mA at 40 kV. The gun geometry is optimized using the Electron Trajectory Program EGUN at a mesh size of 0.2 mm. The beam divergence close to cathode caused by an annular gap of 2 mm between cathode and focusing electrode (FE) is compensated by using a suitable focusing electrode. Important features of the pulsed power supply (40 kV, 500 mA, 2 μsec) developed for testing this gun are presented. The current measured at the Faraday cup is in agreement with the designed perveance. Suitable positioning of cathode with respect to the FE helps in further improving the beam quality

  19. More fun and curiosity with magnetic guns in the classroom

    Science.gov (United States)

    Chittasirinuwat, O.; Kruatong, T.; Paosawatyanyong, B.

    2011-05-01

    The magnetic gun was chosen as a hands-on activity for our high school students. When conducting this activity in the classroom, we found some interesting points were raised following difficulties encountered by the students. Some students proposed that during the collision, the magnet changed its pole then it pushed the last ball out of the apparatus, but some suggested that all the balls were attracted by magnetic forces, therefore the last ball could not shoot out. With a question to raise their curiosity, 'How do magnetic guns work?', our students explored notions of magnetic force, work, and conservation of energy and momentum through their own design of magnetic guns. This article describes a method for measuring the changes of kinetic energy and describes factors that students should consider for making magnetic guns more powerful and for having fun with the activity of building them.

  20. Miniature paint-spray gun for recessed areas

    Science.gov (United States)

    Vanasse, M. A.

    1968-01-01

    Miniature spray gun regulates paints and other liquids to spray at close range, facilitating spraying of remote or recessed areas. Individual valves for regulating air pressure and paint maximizes atomization for low pressure spraying.

  1. Hartford's gun buy-back program: are we on target?

    Science.gov (United States)

    Marinelli, Laura W; Thaker, Shefali; Borrup, Kevin; Shapiro, David S; Bentley, George C; Saleheen, Hassan; Lapidus, Garry; Campbell, Brendan T

    2013-09-01

    Gunbuy-backprograms have been proposed as away to remove unwanted firearms from circulation, but remain controversial because their ability to prevent firearm injuries remains unproven. The purpose of this study is to describe the demographics of individuals participating in Connecticut's gun buy-backprogram in the context of annual gun sales and the epidemiology of firearm violence in the state. Over four years the buy-back program collected 464 firearms, including 232 handguns. In contrast, 91,602 firearms were sold in Connecticut during 2009 alone. The incidence of gun-related deaths was unchanged in the two years following the inception of the buy-back program. Suicide was associated with older age (mean = 51 +/- 18years) and Caucasian race (n = 539, 90%). Homicide was associated with younger age (mean = 30 +/- 12 years) and minority race (n = 425, 81%). A gun buy-back program alone is not likely to produce a measurable decrease in firearm injuries and deaths.

  2. A high current electron gun for the IEAv linac

    International Nuclear Information System (INIS)

    Muraro, A. Jr.; Stopa, C.R.S.; Romao, B.M.V.; Jorge, A.M.; Takahashi, J.

    2001-01-01

    This work presents the design, construction and characterization of a new electron gun for the linear electron accelerator (linac) which is under construction at the Instituto de Estudos Avancados (IEAv)

  3. A numerical study of emittance growths in RF guns

    CERN Document Server

    Masuda, K; Sobajima, M; Kitagaki, J; Ohnishi, M; Toku, H; Yoshikawa, K

    1999-01-01

    A beam with greatly reduced emittance is required for further improvements of FELs, in particular, for FELs of shorter wavelengths, and of narrower bandwidths. From this viewpoint, the BNL/SLAC/UCLA 1.6-cell S-band photocathode RF gun performance characteristics were calculated, first in order to evaluate what may contribute to the emittance growths in photocathode RF guns. We developed an RF gun to produce an electron beam with an extremely low emittance, by using a 2-D simulation code. It is found that, by optimizing the laser injection phase, the drive laser spot radius and the cavity shape around the laser spot, the beam emittance by the 1.6-cell RF gun can be greatly reduced to 2.1 pi mm mrad, from the previous 4.4 pi mm mrad of the original shape.

  4. Ten self-inflicted intracranial penetrating nail gun injuries

    Science.gov (United States)

    Yuh, Sung-Joo; Alaqeel, Ahmed

    2015-01-01

    Penetrating craniocerebral injuries from nail gun use are rare. We describe a case of 10 self-inflicted nail gun injuries with intracranial penetrations. We also review the literature and discuss management strategies of such craniocerebral trauma. A 33-year-old male with a long-standing history of severe depression took a nail gun and sustained 10 penetrating intracranial injuries. Initial neuroimaging revealed 10 penetrating nails, all sparing the major cerebral vasculature. Immediate surgical removal was undertaken in the surgical suite using a combination of craniotomies, craniectomies, and blind removal. Intracranial injuries from self-inflicted nail gun misuse is becoming increasingly more frequent. Initial appropriate clinical decision-making are critical in preventing further cortical or vascular damage. PMID:26166596

  5. Study of an electron gun for metal evaporation

    International Nuclear Information System (INIS)

    Silva, R. da.

    1983-01-01

    In order to design a eletron gun with a long strip beam, an analysis was done using electrostatic lenses. Due the effects of space charge, it was indicated a beam with low current and high energy. (Author) [pt

  6. Research on area source electron gun in vacuum system

    Science.gov (United States)

    Qiu, Yafeng; Chang, Benkang; Shi, Feng; Qian, Yunsheng; Fu, Rongguo

    High-energy area source electron gun is a key component in image intensifier screen testing instrument. On the basis of the analysis of relationship between thermal emission characteristics, the shape of filament and the density of thermal electron emission, high-energy area source electron gun is designed. The distribution of electric field and electronic tracks are theoretically analyzed and calculated to make it has features of dispersing, uniform, converging and submerging. By testing a standard screen, correct the structure of high-energy area source electron gun to meet the requirements of test indexes and obtain reasonable high-energy area source electron gun. Its successful development provides effective technical support to the luminous screen test for uniformity, brightness, luminescence efficiency and afterglow and to the examination of other components (such as MCP parameters)of Low-light Image Intensifier.

  7. Resistance Spot Welding with Middelfrequency-Inverter Weling Gun

    DEFF Research Database (Denmark)

    Rasmussen, Mogens H.

    The paper presents the results of investigations concerning the process stability and weldability lobes for uncoated sheets of 1.0 mm thickness when performing resistance spot welding with a middlefrequency-inverter welding gun......The paper presents the results of investigations concerning the process stability and weldability lobes for uncoated sheets of 1.0 mm thickness when performing resistance spot welding with a middlefrequency-inverter welding gun...

  8. The politics of gun control: comparing Canadian and American patterns

    OpenAIRE

    G A Mauser; M Margolis

    1992-01-01

    In this paper two questions are asked: to what extent do the Canadian and US publics differ in their beliefs about firearms-control legislation, and to what extent do these differences help to account for the stricter firearms legislation found in Canada? Surveys indicate that Canadians and Americans have remarkably similar attitudes towards firearms and gun control. Linear regression is used to analyze the factors that underlie the popular support for (or opposition to) stricter gun-control ...

  9. The Mystery of the Gun Turret in the Desert

    Energy Technology Data Exchange (ETDEWEB)

    Hoffman, R. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-11-30

    The mystery of the gun turret in the desert began with an ingenious idea: to develop a reusable open-air line of sight diagnostic device to support LLNL’s early nuclear weapons development efforts. Obtained from the Mare Island Navy Shipyard (MINS) in January 1957, the gun turret traveled by ship to the Naval Construction Battalion base at Port Hueneme, California, and then by truck to Area 2 in the Yucca Flats valley at the Nevada Nuclear Security Site (NNSS).

  10. Plasma gun with coaxial powder feed and adjustable cathode

    Science.gov (United States)

    Zaplatynsky, Isidor (Inventor)

    1991-01-01

    An improved plasma gun coaxially injects particles of ceramic materials having high melting temperatures into the central portion of a plasma jet. This results in a more uniform and higher temperature and velocity distribution of the sprayed particles. The position of the cathode is adjustable to facilitate optimization of the performance of the gun wherein grains of the ceramic material are melted at lower power input levels.

  11. Ion Back-Bombardment of GaAs Photocathodes Inside DC High Voltage Electron Guns

    CERN Document Server

    Grames, Joseph M; Brittian, Joshua; Charles, Daniel; Clark, Jim; Hansknecht, John; Lynn Stutzman, Marcy; Poelker, Matthew; Surles-Law, Kenneth E

    2005-01-01

    The primary limitation for sustained high quantum efficiency operation of GaAs photocathodes inside DC high voltage electron guns is ion back-bombardment of the photocathode. This process results from ionization of residual gas within the cathode/anode gap by the extracted electron beam, which is subsequently accelerated backwards to the photocathode. The damage mechanism is believed to be either destruction of the negative electron affinity condition at the surface of the photocathode or damage to the crystal structure by implantation of the bombarding ions. This work characterizes ion formation within the anode/cathode gap for gas species typical of UHV vacuum chambers (i.e., hydrogen, carbon monoxide and methane). Calculations and simulations are performed to determine the ion trajectories and stopping distance within the photocathode material. The results of the simulations are compared with test results obtained using a 100 keV DC high voltage GaAs photoemission gun and beamline at currents up to 10 mA D...

  12. Research and development of methods and technologies for CO2 capture in fossil fuel power plants and storage in geological formations in the Czech Republic, stage E2: Methods of and technologies for CO2 capture from flue gas and a draft conceptual design of 2 selected variants of a CO2 capture system for a Czech coal fired power plant unit. Final report for Stage 2. Revision 0

    International Nuclear Information System (INIS)

    Ubra, Olga

    2010-12-01

    The following topics are summarised: Aim and scope of Stage 2. List of research reports developed within Stage 2. Stage 2.1: Methods of and technologies for post-combustion CO 2 capture from the flue gas. Status of research and development worldwide. Stage 2.2: Oxyfuel method and technology. Status of research and development worldwide. Stage 2.3: Selection of a chemical absorption based method for post-combustion CO 2 separation; and Stage 2.4: Conceptual proposals for a technological solution for the selected chemical absorption based method and for application of the oxyfuel method. (P.A.)

  13. Unusual Case of Suicide With a Modified Trap Gun.

    Science.gov (United States)

    Vadysinghe, Amal; Dassanayake, Prasanna; Wickramasinghe, Medhani

    2017-06-01

    Trap gun is an illegal, locally manufactured gun with a basic trip system used to hunt wild animals. The body of a 28-year-old man was found in the jungle in supine position with both legs apart. A trap gun was between the legs pointing toward the cranial side of the body. It had 2 free wires that were not connected together. There was no evidence of foul play.The body had a single-entry wound (2.5-cm diameter) in the anterior chest, with blackening, burning, and tattooing. Six metal particles and nylon clothing material were embedded into soft tissue. No exit wound was found. Toxicology analysis reported an alcohol level of 72 mg/dL. The cause of death was multiple shrapnel injury to the chest at close to intermediate range by a single discharge from a trap gun. Circumstance was concluded as suicide.Ballistic and firearm experts opined that an illegal, manually operated, battery-powered ignition device was used to ignite the gun powder. We report the first case of suicide by a modified trap gun in literature.

  14. A gun recoil system employing a magnetorheological fluid damper

    Science.gov (United States)

    Li, Z. C.; Wang, J.

    2012-10-01

    This research aims to design and control a full scale gun recoil buffering system which works under real firing impact loading conditions. A conventional gun recoil absorber is replaced with a controllable magnetorheological (MR) fluid damper. Through dynamic analysis of the gun recoil system, a theoretical model for optimal design and control of the MR fluid damper for impact loadings is derived. The optimal displacement, velocity and optimal design rules are obtained. By applying the optimal design theory to protect against impact loadings, an MR fluid damper for a full scale gun recoil system is designed and manufactured. An experimental study is carried out on a firing test rig which consists of a 30 mm caliber, multi-action automatic gun with an MR damper mounted to the fixed base through a sliding guide. Experimental buffering results under passive control and optimal control are obtained. By comparison, optimal control is better than passive control, because it produces smaller variation in the recoil force while achieving less displacement of the recoil body. The optimal control strategy presented in this paper is open-loop with no feedback system needed. This means that the control process is sensor-free. This is a great benefit for a buffering system under impact loading, especially for a gun recoil system which usually works in a harsh environment.

  15. A gun recoil system employing a magnetorheological fluid damper

    International Nuclear Information System (INIS)

    Li, Z C; Wang, J

    2012-01-01

    This research aims to design and control a full scale gun recoil buffering system which works under real firing impact loading conditions. A conventional gun recoil absorber is replaced with a controllable magnetorheological (MR) fluid damper. Through dynamic analysis of the gun recoil system, a theoretical model for optimal design and control of the MR fluid damper for impact loadings is derived. The optimal displacement, velocity and optimal design rules are obtained. By applying the optimal design theory to protect against impact loadings, an MR fluid damper for a full scale gun recoil system is designed and manufactured. An experimental study is carried out on a firing test rig which consists of a 30 mm caliber, multi-action automatic gun with an MR damper mounted to the fixed base through a sliding guide. Experimental buffering results under passive control and optimal control are obtained. By comparison, optimal control is better than passive control, because it produces smaller variation in the recoil force while achieving less displacement of the recoil body. The optimal control strategy presented in this paper is open-loop with no feedback system needed. This means that the control process is sensor-free. This is a great benefit for a buffering system under impact loading, especially for a gun recoil system which usually works in a harsh environment. (paper)

  16. Contoured-gap coaxial guns for imploding plasma liner experiments

    Science.gov (United States)

    Witherspoon, F. D.; Case, A.; Brockington, S.; Cassibry, J. T.; Hsu, S. C.

    2014-10-01

    Arrays of supersonic, high momentum flux plasma jets can be used as standoff compression drivers for generating spherically imploding plasma liners for driving magneto-inertial fusion, hence the name plasma-jet-driven MIF (PJMIF). HyperV developed linear plasma jets for the Plasma Liner Experiment (PLX) at LANL where two guns were successfully tested. Further development at HyperV resulted in achieving the PLX goal of 8000 μg at 50 km/s. Prior work on contoured-gap coaxial guns demonstrated an approach to control the blowby instability and achieved substantial performance improvements. For future plasma liner experiments we propose to use contoured-gap coaxial guns with small Minirailgun injectors. We will describe such a gun for a 60-gun plasma liner experiment. Discussion topics will include impurity control, plasma jet symmetry and topology (esp. related to uniformity and compactness), velocity capability, and techniques planned for achieving gun efficiency of >50% using tailored impedance matched pulse forming networks. Mach2 and UAH SPH code simulations will be included. Work supported by US DOE DE-FG02-05ER54810.

  17. Simulation of electron beam from two strip electron guns and control of power density by rotation of gun

    International Nuclear Information System (INIS)

    Sahu, G K; Baruah, S; Thakur, K B

    2012-01-01

    Electron beam is preferably used for large scale evaporation of refractory materials. Material evaporation from a long and narrow source providing a well collimated wedge shaped atomic beam has applications in isotopic purification of metals relevant to nuclear industry. The electron beam from an electron gun with strip type filament provides a linear heating source. However, the high power density of the electron beam can lead to turbulence of the melt pool and undesirable splashing of molten metal. For obtaining quiet surface evaporation, the linear electron beam is generally scanned along its length. To further reduce the power density to maintain quiet evaporation the width of the vapour source can be controlled by rotating the electron gun on its plane, thereby scanning an inclined beam over the molten pool. The rotation of gun has further advantages. When multiple strip type electron guns are used for scaling up evaporation length, a dark zone appears between two beams due to physical separation of adjacent guns. This dark zone can be reduced by rotating the gun and thereby bringing two adjacent beams closer. The paper presented here provides the simulation results of the electron beam trajectory and incident power density originating from two strip electron guns by using in-house developed code. The effect of electron gun rotation on the electron beam trajectory and power density is studied. The simulation result is experimentally verified with the image of molten pool and heat affected zone taken after experiment. This technique can be gainfully utilized in controlling the time averaged power density of the electron beam and obtaining quiet evaporation from the metal molten pool.

  18. Performance of a Liner-on-Target Injector for Staged Z-Pinch Experiments

    Science.gov (United States)

    Conti, F.; Valenzuela, J. C.; Narkis, J.; Krasheninnikov, I.; Beg, F.; Wessel, F. J.; Ruskov, E.; Rahman, H. U.; McGee, E.

    2016-10-01

    We present the design and characterization of a compact liner-on-target injector, used in the Staged Z-pinch experiments conducted on the UNR-NTF Zebra Facility. Previous experiments and analysis indicate that high-Z gas liners produce a uniform and efficient implosion on a low-Z target plasma. The liner gas shell is produced by an annular solenoid valve and a converging-diverging nozzle designed to achieve a collimated, supersonic, Mach-5 flow. The on-axis target is produced by a coaxial plasma gun, where a high voltage pulse is applied to ionize neutral gas and accelerate the plasma by the J-> × B-> force. Measurements of the liner and target dynamics, resolved by interferometry in space and time, fast imaging, and collection of the emitted light, are presented. The results are compared to the predictions from Computational Fluid Dynamics and MHD simulations that model the injector. Optimization of the design parameters, for upcoming Staged Z-pinch experiments, will be discussed. Advanced Research Projects Agency - Energy, DE-AR0000569.

  19. Air pollution: a smoking gun for cancer.

    Science.gov (United States)

    Zhang, Wei; Qian, Chao-Nan; Zeng, Yi-Xin

    2014-04-01

    Once considered a taboo topic or stigma, cancer is the number one public health enemy in the world. Once a product of an almost untouchable industry, tobacco is indisputably recognized as a major cause of cancer and a target for anticancer efforts. With the emergence of new economic powers in the world, especially in highly populated countries such as China, air pollution has rapidly emerged as a smoking gun for cancer and has become a hot topic for public health debate because of the complex political, economic, scientific, and technologic issues surrounding the air pollution problem. This editorial and the referred articles published in this special issue of the Chinese Journal of Cancer discuss these fundamental questions. Does air pollution cause a wide spectrum of cancers? Should air pollution be considered a necessary evil accompanying economic transformation in developing countries? Is an explosion of cancer incidence coming to China and how soon will it arrive? What must be done to prevent this possible human catastrophe? Finally, the approaches for air pollution control are also discussed.

  20. Age, Poverty, Homicide, and Gun Homicide

    Directory of Open Access Journals (Sweden)

    Mike Males

    2015-03-01

    Full Text Available Traditional theories of “adolescent risk taking” have not been validated against recent research indicating that youthful traffic crash, violent crime, felony crime, and firearms mortality rates reflect young people’s low-socio-economic status (SES compared with older adults’, not young age. Aside from a small number of recent, conflicting studies, the literature gap on this key issue remains. The present study examines the 54,094 homicide deaths, including 41,123 gun homicides, victimizing California residents ages 15 to 69 during 1991 to 2012 by poverty status. Without controlling for poverty, homicide rates display the traditional age-curve peaking at 19, then declining. When poverty is controlled, the traditional age-curve persists only for high-poverty populations, in which young people are vastly over-represented, and homicide rates are elevated for all ages. This finding reiterates that “adolescent risk taking” may be an artifact of failing to control for age-divergent SES.

  1. Water guns affect abundance and behavior of bigheaded carp and native fish differently

    Science.gov (United States)

    Rivera, Jose; Glover, David C.; Kocovsky, Patrick; Garvey, James E.; Gaikowski, Mark; Jensen, Nathan R.; Adams, Ryan F.

    2017-01-01

    Water guns have shown the potential to repel nuisance aquatic organisms. This study examines the effects of exposure to a 1966.4 cm3 seismic water gun array (two guns) on the abundance and behavior of Bighead Carp Hypophthalmichthys nobilis, Silver Carp H. molitrix (collectively referred to as bigheaded carp) and native fishes (e.g., Smallmouth Buffalo Ictiobus bubalus). Water guns were deployed in a channel that connects the Illinois River to backwater quarry pits that contained a large transient population of bigheaded carp. To evaluate the effect of water guns, mobile side-looking split-beam hydroacoustic surveys were conducted before, during and between replicated water gun firing periods. Water guns did not affect abundance of bigheaded carp, but abundance of native fish detected during the firing treatment was 43 and 34% lower than the control and water guns off treatments, respectively. The proximity of bigheaded carp to the water gun array was similar between the water guns on and water guns off treatments. In contrast, the closest detected native fish were detected farther from the water guns during the water guns on treatment (mean ± SE, 32.38 ± 3.32 m) than during the water guns off treatment (15.04 ± 1.59 m). The water gun array had a greater impact on native fish species than on bigheaded carp. Caution should be taken to the extrapolation of these results to other fish species and to fish exposed to water guns in different environments (e.g., reduced shoreline interaction) or exposure to a larger array of water guns, or for use of water guns for purposes other than a barrier.

  2. A novel electron gun for inline MRI-linac configurations

    International Nuclear Information System (INIS)

    Constantin, Dragoş E.; Fahrig, Rebecca; Holloway, Lois; Keall, Paul J.

    2014-01-01

    Purpose: This work introduces a new electron gun geometry capable of robust functioning in the presence of a high strength external magnetic field for axisymmetric magnetic resonance imaging (MRI)-linac configurations. This allows an inline MRI-linac to operate without the need to isolate the linear accelerator (linac) using a magnetic shield. This MRI-linac integration approach not only leaves the magnet homogeneity unchanged but also provides the linac flexibility to move along the magnet axis of symmetry if the source to target distance needs to be adjusted. Methods: Simple electron gun geometry modifications of a Varian 600C electron gun are considered and solved in the presence of an external magnetic field in order to determine a set of design principles for the new geometry. Based on these results, a new gun geometry is proposed and optimized in the fringe field of a 0.5 T open bore MRI magnet (GE Signa SP). A computer model for the 6 MeV Varian 600C linac is used to determine the capture efficiency of the new electron gun-linac system in the presence of the fringe field of the same MRI scanner. The behavior of the new electron gun plus the linac system is also studied in the fringe fields of two other magnets, a 1.0 T prototype open bore magnet and a 1.5 T GE Conquest scanner. Results: Simple geometrical modifications of the original electron gun geometry do not provide feasible solutions. However, these tests show that a smaller transverse cathode diameter with a flat surface and a slightly larger anode diameter could alleviate the current loss due to beam interactions with the anode in the presence of magnetic fields. Based on these findings, an initial geometry resembling a parallel plate capacitor with a hole in the anode is proposed. The optimization procedure finds a cathode-anode distance of 5 mm, a focusing electrode angle of 5°, and an anode drift tube length of 17.1 mm. Also, the linac can be displaced with ±15 cm along the axis of the 0.5 T

  3. Electron-gun Evaporation of Cu and In thin Films as Precursors for CuInSe, Formation

    International Nuclear Information System (INIS)

    Caballero, R.; Guillen, C.

    2001-01-01

    In the present invigorations CuInSe, is obtained in two stages: sequential evaporation of Cu and In using an electron gun evaporator on substrates up to 30 x 30 cm 2 , and a posterior selenization of the deposited films. The study is mainly focused on the first stage, in where the control of the different evaporation parameters of the metal precursors is essential. Electrical measurements are carried out, and also the topography and the thickness are determined with the object of studying the properties and homogeneity of the thin films. (Author) 19 refs

  4. A further step toward H2 in automobile : development of an efficient bi-functional catalyst for single stage water gas shift

    NARCIS (Netherlands)

    Azzam, K.G.H.

    2008-01-01

    The suitability of polymer electrolyte fuel (PEM) cells for stationary and vehicular applications initiated research in all areas of fuel processor (i.e. reformer, water-gas-shift, preferential oxidation of CO (PROX)) catalysts for hydrogen generation. Water gas shift (WGS) reaction is an essential

  5. A high voltage test stand for electron gun qualification for LINACs

    International Nuclear Information System (INIS)

    Wanmode, Yashwant D.; Mulchandani, J.; Acharya, M.; Bhisikar, A.; Singh, H.G.; Shrivastava, Purushottam

    2011-01-01

    An electron gun lest stand has been developed at RRCAT. The test stand consists of a high voltage pulsed power supply, electron gun filament supply, grid supply, UHV system and electron gun current measurement system. Several electron guns developed indigenously were evaluated on this test stand. The shielding is provided for the electron gun set up. Electron gun tests can be tested upto 55 kV with pulse width of 15 microsecs and pulse repetition rates up to 200 Hz. The technical details of the subsystems are furnished and results of performance of the test stand have been reported in this paper. (author)

  6. The gun-slave hypothesis and the 18th century British slave trade

    OpenAIRE

    Whatley, Warren

    2017-01-01

    The Gun-Slave Hypothesis is the long-standing idea that European gunpowder technology played a key role in growing the transatlantic slave trade. I combine annual data from the Transatlantic Slave Trade Database and the Anglo-African Trade Statistics to estimate a Vector Error Correction Model of the 18th century British slave trade that captures four versions of the Gun-Slave Hypothesis: guns-for-slaves-in-exchange, guns-for-slaves-in-production, slaves-for-guns-derived and the gun-slave cyc...

  7. RF Processing Experience with the GTF Prototype RF Gun

    International Nuclear Information System (INIS)

    Schmerge, J.F.

    2010-01-01

    The SSRL Gun Test Facility (GTF) was built to develop a high brightness electron injector for the LCLS and has been operational since 1996. A total of five different metal cathodes (4 Cu and 1 Mg) have been installed on the GTF gun. The rf processing history with the different cathodes will be presented including peak field achieved at the cathode. The LCLS gun is intended to operate at 120 MV/m and fields up to 140 MV/m have been achieved in the GTF gun. After installing a new cathode the number of rf pulses required to reach 120 MV/m is approximately 5-10 million. Total emitted dark current and Fowler Nordheim plots are also shown over the life of the cathode. The GTF photo-injector gun is an S-band standing-wave structure, with two resonant cavities and an intervening thick washer (Figure 1). The flat, back wall of the first cavity is a copper plate that serves as photocathode when illuminated with ultraviolet light from a pulsed, high-power laser. RF power enters the gun through an iris on the outer wall of the second cavity, and is coupled to the first through the axial opening of the washer. The first cavity is often referred to as a half cell, because its full-cell length has been truncated by the cathode plate and the second cavity is called the full cell. The gun is designed to operate in a π mode, with the peak field on axis in each cell approximately equal. The maximum in the half cell occurs at the cathode, and in the full cell near the center of the cavity. The field profile and tuning procedures are discussed in a separate tech note (1).

  8. Does gun accessibility lead to violence-related injury?

    Science.gov (United States)

    Downey, La Vonne A; Zun, Leslie S; Burke, Trena; Jefferson, Tangula

    2013-02-01

    Because of high rates of violent gun-related injuries seen in emergency department (EDs), the ED has become involved in prevention violence intervention. The purpose of the study was to determine the relation between access to guns and the risk of violence-related injuries in youth and young adults. This study was a convenience sample in an inner-city level I trauma center. A 28-item validated questionnaire consisting of a short questionnaire about guns, the New York City Youth Violence Survey, and the SAGE Baseline Survey was given to 201 subjects. Half of the subjects were victims of violence and half were seen for nonviolence-related problems. Subjects with violence-related injuries did not have a higher rate of accessibility to guns. They did, however, show a difference in their attitudes toward guns. The subjects who came into the ED with violence-related injuries believed that having a weapon was a way to avoid a fight (F = 4.68, P = 0.032). They were more likely to have grabbed or shoved someone in the last 6 months (F = 5.18, P = 0.025), punched someone in the last 6 months (F = 11.9, P = 0.011), and have been seen in the ED within the last 6 months for a injury related to being punched, attacked, or shot (F = 117, P = 0.00), as compared to those with nonviolence-related injuries. There was no difference between the two subject groups in terms of their being victims of violence and the rate of gun accessibility. There was, however, a difference in their attitudes toward guns.

  9. Gun availability and use of guns for suicide, homicide, and murder in Canada.

    Science.gov (United States)

    Bridges, F Stephen; Kunselman, Julie C

    2004-04-01

    A reliability check of Lester's (2000b) 1970-1995 time series that examined associations between the availability of firearms and their use for homicide and suicide in Canada. For the period 1974 to 1999, the relative availability of firearms as measured by the rate of accidental death from firearms and the average of the percentages of suicides + homicides using firearms was positively associated with the rate of homicide by firearms but not negatively associated with the rate of homicide by all other methods, and positively associated with the rate of suicide by firearms and negatively associated with the rate of suicide by all other methods. Correlations for the homicide versus murder rates, homicide rate using guns versus murder rate using guns, and homicide rate by all other methods versus murder rate by all other methods were very similar. There was a decrease over time of total suicide and homicide rates and firearm suicide and homicide rates, and with a slight indication of substitution of other methods for suicide.

  10. Background Checks for all Gun Buyers and Gun Violence Restraining Orders: State Efforts to Keep Guns from High-Risk Persons.

    Science.gov (United States)

    Vernick, Jon S; Alcorn, Ted; Horwitz, Joshua

    2017-03-01

    There were more than 36,000 firearm-related deaths in the U.S. in 2015. Under federal law, a background check is required only for gun purchases from licensed dealers. Research suggests that some persons prohibited from owning a gun turn to private sellers, including those identified online, to attempt to obtain a firearm. State-level approaches to make it more difficult for high-risk persons to purchase or possess firearms include universal background check (UBC) and gun violence restraining order (GVRO) laws. UBC laws, on the books in 18 states as of the end of 2016, can reduce both homicide and suicide rates. After Colorado adopted a UBC law in 2013, the number of background checks conducted by private sellers for sales occurring at places other than gun shows steadily increased. GVRO laws give law enforcement and families the authority to petition a court to temporarily remove firearms from an individual who presents a danger to himself or others during times of crisis, regardless of whether that person has been diagnosed with a mental illness. California enacted a GVRO law in 2014. Data are emerging to suggest the effectiveness of GVRO-type laws at averting suicides and providing an entryway to services.

  11. Research on Miniature Calibre Rail-Guns for the Mechanical Arm

    Directory of Open Access Journals (Sweden)

    Ronggang Cao

    2017-01-01

    Full Text Available Rail-gun should not only be used to military applications, but also can be developed as applications in the civilian aspects of the market. With the development of the electromagnetic launch technology, based on the similarity theory, using the existing rail-gun model to guide the construction of more economical miniature calibre rail-guns, and apply it in some machinery and equipment, this idea will open up a wider rail-gun application space. This article will focus on the feasibility of application of miniature calibre rail-guns in the mechanical arm. This paper designs the schematic diagram, then theoretical analyzes force conditions of the armature in the mechanical arm, calculates the possible range of the current amplitude and so on. The existing rail-gun model can be used to guides design the circuit diagram of the miniature calibre rail-gun. Based on the similarity theory and many simulation experiments, designed the experimental parameters of a miniature rail-gun and analyzed the current, Lorentz force, velocity, and location of the existing rail-gun and miniature rail-gun. The results show that the rail-gun launching technology applied to robot arms is feasibility. The application of miniature calibre rail-guns in the mechanical arm will benefit to the further development of rail-guns.

  12. rf traveling-wave electron gun for photoinjectors

    Directory of Open Access Journals (Sweden)

    Mattia Schaer

    2016-07-01

    Full Text Available The design of a photoinjector, in particular that of the electron source, is of central importance for free electron laser (FEL machines where a high beam brightness is required. In comparison to standard designs, an rf traveling-wave photocathode gun can provide a more rigid beam with a higher brightness and a shorter pulse. This is illustrated by applying a specific optimization procedure to the SwissFEL photoinjector, for which a brightness improvement up to a factor 3 could be achieved together with a double gun output energy compared to the reference setup foreseeing a state-of-the-art S-band rf standing-wave gun. The higher brightness is mainly given by a (at least double peak current at the exit of the gun which brings benefits for both the beam dynamics in the linac and the efficiency of the FEL process. The gun design foresees an innovative coaxial rf coupling at both ends of the structure which allows a solenoid with integrated bucking coil to be placed around the cathode in order to provide the necessary focusing right after emission.

  13. rf traveling-wave electron gun for photoinjectors

    Science.gov (United States)

    Schaer, Mattia; Citterio, Alessandro; Craievich, Paolo; Reiche, Sven; Stingelin, Lukas; Zennaro, Riccardo

    2016-07-01

    The design of a photoinjector, in particular that of the electron source, is of central importance for free electron laser (FEL) machines where a high beam brightness is required. In comparison to standard designs, an rf traveling-wave photocathode gun can provide a more rigid beam with a higher brightness and a shorter pulse. This is illustrated by applying a specific optimization procedure to the SwissFEL photoinjector, for which a brightness improvement up to a factor 3 could be achieved together with a double gun output energy compared to the reference setup foreseeing a state-of-the-art S-band rf standing-wave gun. The higher brightness is mainly given by a (at least) double peak current at the exit of the gun which brings benefits for both the beam dynamics in the linac and the efficiency of the FEL process. The gun design foresees an innovative coaxial rf coupling at both ends of the structure which allows a solenoid with integrated bucking coil to be placed around the cathode in order to provide the necessary focusing right after emission.

  14. Momentum equation for arc-driven rail guns

    International Nuclear Information System (INIS)

    Batteh, J.H.

    1984-01-01

    In several models of arc-driven rail guns, the rails are assumed to be infinitely high to simplify the calculation of the electromagnetic fields which appear in the momentum equation for the arc. This assumption leads to overestimates of the arc pressures and accelerations by approximately a factor of 2 for typical rail-gun geometries. In this paper, we develop a simple method for modifying the momentum equation to account for the effect of finite-height rails on the performance of the rail gun and the properties of the arc. The modification is based on an integration of the Lorentz force across the arc cross section at each axial location in the arc. Application of this technique suggests that, for typical rail-gun geometries and moderately long arcs, the momentum equation appropriate for infinite-height rails can be retained provided that the magnetic pressure term in the equation is scaled by a factor which depends on the effective inductance of the gun. The analysis also indicates that the magnetic pressure gradient actually changes sign near the arc/projectile boundary because of the magnetic fields associated with the arc current

  15. Characterization of the C-2W Plasma Guns

    Science.gov (United States)

    Dubois, Ami; Sokolov, Vladimir; Korepanov, Sergey; Osin, Dima; Player, Gabriel; TAE Team

    2017-10-01

    Previous use of coaxial arc discharge plasma guns on the C-2U device exhibited great success in plasma stabilization and improved confinement. On the C-2W experiment, arc discharge plasma guns will again be used to facilitate the electrical connection between the plasma core and the divertor electrodes in order to maintain the electrode edge biasing and induce E x B shear to control plasma rotation. Each plasma gun contains an internal solenoid used to shape the plasma stream. Characterization of electron density (ne) , electron temperature (Te) , floating potential (Vf) , and total plasma flux in an arc discharge lasting 6 ms without the internal solenoid are presented. A Langmuir probe located 27 cm axially outside of the plasma gun anode measures a bell-like radial ne profile with peak ne 1018 m-3 and Te 2 - 10 eV. Observed spectral lines of impurity ions provide an estimate of Te, and Balmer series line ratios of the main ion component are used to evaluate ne at both the probe location and near the plasma gun anode. A calorimeter measures the plasma flux to be constant and equivalent to 1 kA.

  16. Numerical design of electron guns and space charge limited transport systems

    International Nuclear Information System (INIS)

    Herrmannsfeldt, W.B.

    1980-10-01

    This paper describes the capabilities and limitations of computer programs used to design electron guns and similarly space-charge limited transport systems. Examples of computer generated plots from several different types of gun problems are included

  17. Non-channel magnetron gun as the electron source for resonance linear accelerator

    International Nuclear Information System (INIS)

    Ivanov, G.M.; Makhnenko, L.A.; Cherenshchikov, S.A.

    1999-01-01

    Studies on the magnetron gun with a cold cathode being part of linear accelerator on the travelling wave are described. Two modes of the gun operation differing by presence of UHF field of the pre-buncher near the gun are observed. In the mode without UHF field the short (about 2 ns) pulses of accelerated electrons with amplitude up to 0.5 A at the gun current up to 20 A were obtained. The presence of UHF field near the gun makes it possible to obtain the beam of higher duration (up to 1.0 μs), but with current up to 20 mA at the accelerator outlet and up to 1 A at the gun outlet. The mechanism of the gun operation is concerned with the secondary-electron current increase and setting self-sustaining secondary emission. Gun characteristics under study are acceptable for the purposes of injection into accelerator [ru

  18. Thermochemical Erosion Modeling of the 25-MM M242/M791 Gun System

    National Research Council Canada - National Science Library

    Sopok, Samuel

    1997-01-01

    The MACE gun barrel thermochemical erosion modeling code addresses wall degradations due to transformations, chemical reactions, and cracking coupled with pure mechanical erosion for the 25-mm M242/M791 gun system...

  19. Application of Coaxial Ion Gun for Film Generation and Ion Implantation

    Science.gov (United States)

    Takatsu, Mikio; Asai, Tomohiko; Kurumi, Satoshi; Suzuki, Kaoru; Hirose, Hideharu; Masutani, Shigeyuki

    A magnetized coaxial plasma gun (MCPG) is here utilized for deposition on high-melting-point metals. MCPGs have hitherto been studied mostly in the context of nuclear fusion research, for particle and magnetic helicity injection and spheromak formation. During spheromak formation, the electrode materials are ionized and mixed into the plasmoid. In this study, this ablation process by gun-current sputtering is enhanced for metallic thin-film generation. In the proposed system geometry, only ionized materials are electromagnetically accelerated by the self-Lorentz force, with ionized operating gas as a magnetized thermal plasmoid, contributing to the thin-film deposition. This reduces the impurity and non-uniformity of the deposited thin-film. Furthermore, as the ions are accelerated in a parallel direction to the injection axis, vertical implantation of the ions into the substrate surface is achieved. To test a potential application of the developed system, experiments were conducted involving the formation of a buffer layer on hard ceramics, for use in dental materials.

  20. Flow Characterization of a Detonation Gun Facility and First Coating Experiments

    Science.gov (United States)

    Henkes, C.; Olivier, H.

    2014-06-01

    A computer-controlled detonation gun based spraying device has been designed and tested to obtain particle velocities over 1200 m/s. The device is able to be operated in two modes based on different flow-physical principles. In one mode, the device functions like a conventional detonation gun in which the powder is accelerated in a blast wave. In the other mode, an extension of the facility with a nozzle uses the detonated gas for an intermittently operated shock tunnel process in which the particles are injected into and accelerated by a quasi-steady high enthalpy nozzle flow with high reservoir conditions. Presented are experimental results of the operation without nozzle in which the device generates moderate to high particle velocities in an intermittent process with a frequency of 5 Hz. A hydrogen/oxygen mixture and Cu and WC-Co (88/12) powders are used in the experiments. Operation performance and tube outflow are characterized by time-resolved Schlieren images and pressure measurements. The particle velocities in the outflow are obtained by laser Doppler anemometry. Different substrate/powder combinations (Al/Cu, Steel/Cu, Al/WC-Co, and Steel/WC-Co) have been investigated by light microscopy and measurements of microhardness.

  1. An Independently Tunable Cells Thermionic RF Gun (ITC-RF GUN) for Sub-Picosecond Short Pulse

    CERN Document Server

    Hama, H; Kawai, M; Tanaka, T

    2005-01-01

    As a result of simulation study so far, a specific feature has been found in the longitudinal dynamics in thermionic RF guns. At the beginning of beam extraction, the head of the electrons from a cathode is followed immediately by the electrons just behind, which is extracted by the higher electric field than that at the head of the beam train. Thus later electrons would get velocity faster than the head of the electrons, so that the electrons are expected to concentrates onto the head of the beam under certain conditions such as the gun geometry and the strength of the RF field. In order to investigate this velocity-bunching like effect, a prototype thermionic RF gun was designed and its characteristics have been studied by a 3-D simulation code based on a FDTD (finite difference time demain) method. The gun is consists of two independentlly power feeding S-band RF cavities, and can be operated at modes with different power ratio and phase between two RFs. This paper report the thermionic RF gun is expected ...

  2. Strong gun laws are not enough: the need for improved enforcement of secondhand gun transfer laws in Massachusetts.

    Science.gov (United States)

    Braga, Anthony A; Hureau, David M

    2015-10-01

    Research suggests that an overwhelming majority of crime guns were transferred by private sellers before recovery by law enforcement. Unfortunately, most states do not regulate these transactions. This study examines whether analyses of state-level private transfer data could be used to develop interventions to reduce the supply of handguns to violent criminals. Traced Boston crime handguns first sold at Massachusetts license dealers were matched to state secondhand gun transfer data. Logistic regression and descriptive statistics were used to analyze the characteristics of recovered crime guns and in-state primary and secondary market transaction patterns. For crime handguns with records of secondary market transactions in Massachusetts, many rapidly move from private transfer to recovery by the police. Unfortunately, important transaction data on the in-state sources of nearly 63% of recovered handguns were not readily available to law enforcement agencies. Data on private transfers of guns could be used to prevent violent injuries by reducing criminal access. However, the passage of strong private transfer gun laws needs to be accompanied by investments in the vigorous enforcement of reporting requirements. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Modelling and simulation of beam formation in electron guns

    International Nuclear Information System (INIS)

    Sabchevski, S.; Barbarich, I.

    1996-01-01

    This paper describes a new PC version of the software package GUN-EBT for computer simulation of beam formation in rotationally symmetric electron guns with thermionic cathodes. It is based on a self-consistent physical model which takes into account the beam space charge and the initial velocity effects. The theoretical framework used for both the formulation of the model and for the interpretation of the results of numerical experiments is the formalism of the charged particle dynamics in phase space. This enables not only a trajectory analysis (ray tracing) but also a phase-space analysis of beams to be performed. The package can be used as an effective tool for computer aided design and optimization of electron guns in various electron-optical systems. The operation of the package is illustrated with a typical example. (orig.)

  4. Modelling and simulation of beam formation in electron guns

    Energy Technology Data Exchange (ETDEWEB)

    Sabchevski, S. [Bulgarian Academy of Sciences, Sofia (Bulgaria). Inst. po Elektronika; Mladenov, G. [Bulgarian Academy of Sciences, Sofia (Bulgaria). Inst. po Elektronika; Titov, A. [St. Petersburg State Electrotechnical University, St. Petersburg (Russian Federation); Barbarich, I. [St. Petersburg State Electrotechnical University, St. Petersburg (Russian Federation)

    1996-11-01

    This paper describes a new PC version of the software package GUN-EBT for computer simulation of beam formation in rotationally symmetric electron guns with thermionic cathodes. It is based on a self-consistent physical model which takes into account the beam space charge and the initial velocity effects. The theoretical framework used for both the formulation of the model and for the interpretation of the results of numerical experiments is the formalism of the charged particle dynamics in phase space. This enables not only a trajectory analysis (ray tracing) but also a phase-space analysis of beams to be performed. The package can be used as an effective tool for computer aided design and optimization of electron guns in various electron-optical systems. The operation of the package is illustrated with a typical example. (orig.).

  5. Upgraded G-optk program for electron gun characterization

    International Nuclear Information System (INIS)

    Nagasao, K.; Takebe, M.; Ushio, W.; Fujita, S.; Ohye, T.; Shimoyama, H.

    2011-01-01

    The generalized trajectory theory (the G-optk program) has been extended in order to make the method applicable to electron guns with curved and/or asymmetric cathodes. The object-image analysis mode has also been added. Enhanced capability of the upgraded G-optk program was demonstrated by applying the program to three electron optical systems: (a) the point cathode gun, (b) the hairpin-type cathode gun, and (c) the LEEM objective lens. The Canonical Mapping Transformation (CMT) diagrams were calculated both by direct ray tracing and by the upgraded G-optk program. In each case, it was found that the upgraded program reproduces well the results obtained by ray tracing. The generalized trajectory method has several advantages over direct ray tracing, such as substantially lighter calculation load and easy interpretation of the calculation results in terms of the optical parameters.

  6. Emittance compensation of CW DC-gun photoinjector

    International Nuclear Information System (INIS)

    Li Peng; Wu Dai; Xu Zhou; Li Ming; Yang Xingfan

    2011-01-01

    Emittance growth induced by space charge effect is very important, especially for CW DC-gun photoinjector. In this work, the linear space charge force and its effect on electron beam transverse emittance are studied, and the principle and properties of emittance compensation by solenoid are analyzed. The CAEP DC-gun photoinjector with a solenoid is also simulated by code Parmela. Simulated results indicate that the normalized transverse emittance of an 80 pC bunch at the 350 keV DC-gun ex-it is 5.14 mm · mrad. And after compensated by a solenoid, it becomes 1.27 mm · mrad. The emittance of beam is well compensated. (authors)

  7. Trapping of gun-injected plasma by a tokamak

    International Nuclear Information System (INIS)

    Leonard, A.W.; Dexter, R.N.; Sprott, J.C.

    1986-10-01

    It is shown that a plasma produced by a Marshall gun can be injected into and trapped by a tokamak plasma. Gun injection raises the line-averaged density and peaks the density profile. Trapping of the gun-injected plasma is explainable in terms of a depolarization current mechanism. A model is developed which describes the slowing of a plasma beam crossing into the magnetic field of a tokamak. The slowing down time is shown to go as tau/sub s/ ∞ n -1 /sub b/T 3 /sub e/(α 0 /L) 2 , where n/sub b/ and T/sub e/ are the density and temperature of the plasma beam and α 0 /L is the pitch of the field lines per unit length in the direction in which the beam is traveling. Experimental tests of this model are consistent with the scaling predictions

  8. Response of potato to drip and gun irrigation systems

    DEFF Research Database (Denmark)

    Zhenjiang, Zhou; Andersen, Mathias Neumann; Plauborg, Finn

    2015-01-01

    The objective of this study was to evaluate effects of different irrigation and N fertilization regimes by gun irrigation and drip-fertigation on potato production, and subsequently optimize the supply of water and N fertilizer to the growth condition of the specific season and minimize nitrate......-fertigation system (DFdsNds) and two gun irrigation systems (GIdsN120 and GIaN120) to display the differences on growth, yield and water use efficiency of potato. All treatments were irrigated according to model simulated soil water content. For fertilization all treatments received a basic dressing at planting of P......, K, Mg and micronutrients, and in addition 120 kg N/ha in the gun irrigated treatments and 36 kg N/ha in the drip-fertigated. For the latter, portion of 20 kg N/ha was applied whenever plant N concentration approached a critical value as simulated by the Daisy model. As a result differences in soil...

  9. Carrying guns in public: legal and public health implications.

    Science.gov (United States)

    Vernick, Jon S

    2013-03-01

    In District of Columbia v. Heller, the U.S. Supreme Court ruled that the Second Amendment protects an individual's right to own handguns in the home for protection, invalidating a Washington, D.C. law banning most handgun possession. The Heller decision, however, provided lower courts with little guidance regarding how to judge the constitutionality of gun laws other than handgun bans. Nevertheless, lower courts have upheld the vast majority of federal, state, and local gun laws challenged since Heller. One area in which some lower courts have disagreed has been the constitutionality of laws regulating the ability to carry firearms in public. This issue may be the next to be addressed by the Supreme Court under its evolving Second Amendment jurisprudence. Courts should carefully consider the negative public health and safety implications of gun carrying in public as they weigh the constitutionality of these laws. © 2013 American Society of Law, Medicine & Ethics, Inc.

  10. Longitudinal Jitter Analysis of a Linear Accelerator Electron Gun

    Directory of Open Access Journals (Sweden)

    MingShan Liu

    2016-11-01

    Full Text Available We present measurements and analysis of the longitudinal timing jitter of a Beijing Electron Positron Collider (BEPCII linear accelerator electron gun. We simulated the longitudinal jitter effect of the gun using PARMELA to evaluate beam performance, including: beam profile, average energy, energy spread, and XY emittances. The maximum percentage difference of the beam parameters is calculated to be 100%, 13.27%, 42.24% and 65.01%, 86.81%, respectively. Due to this, the bunching efficiency is reduced to 54%. However, the longitudinal phase difference of the reference particle was 9.89°. The simulation results are in agreement with tests and are helpful to optimize the beam parameters by tuning the trigger timing of the gun during the bunching process.

  11. A design study of non-adiabatic electron guns

    International Nuclear Information System (INIS)

    Barroso, J.J.; Stellati, C.

    1994-01-01

    The design of a non-adiabatic gun capable of producing a 10 A, 50 KeV high-quality laminar electron beam is reported. In contrast to the magnetron injection gun with a conical cathode, where the beam is generated initially with a transverse velocity component, in the non-adiabatic gun electrons are extracted in a direction parallel to the axial guide magnetic field. The beam electrons acquire cyclotron motion as result of non-adiabatic processes in a strong non uniform electric field across the modulation anode. Such an extraction method gives rise to favourable features that are explored throughout the work. An extensive numerical simulation study has also been done to minimize velocity and energy spreads. (author). 3 refs, 5 figs, 1 tab

  12. A pulsed electron gun for the Plane Wave Transformer Linac

    CERN Document Server

    Mahadevan, S; Nandedkar, R V

    2003-01-01

    A pulsed diode electron gun delivering 500 mA current at 40 kV is described. The gun geometry is optimized using the Electron Trajectory Program EGUN at higher scaling factors by choosing the closest converging starting surface. The effect of an annular gap between cathode and focusing electrode on beam behaviour is compensated by using a suitable focusing electrode. The estimated perveance is 0.065 mu perv and the normalized emittance is within 5 pi mm mrad. The variation in current density at the cathode has been limited to within 10% across the face of the cathode. Salient features of the pulsed power supply and an insight of its interconnection with the gun are presented. The current measured at the Faraday cup is in agreement with the designed perveance.

  13. The challenge of gun control for mental health advocates.

    Science.gov (United States)

    Pandya, Anand

    2013-09-01

    Mass shootings, such as the 2012 Newtown massacre, have repeatedly led to political discourse about limiting access to guns for individuals with serious mental illness. Although the political climate after such tragic events poses a considerable challenge to mental health advocates who wish to minimize unsympathetic portrayals of those with mental illness, such media attention may be a rare opportunity to focus attention on risks of victimization of those with serious mental illness and barriers to obtaining psychiatric care. Current federal gun control laws may discourage individuals from seeking psychiatric treatment and describe individuals with mental illness using anachronistic, imprecise, and gratuitously stigmatizing language. This article lays out potential talking points that may be useful after future gun violence.

  14. Rf Gun with High-Current Density Field Emission Cathode

    International Nuclear Information System (INIS)

    Jay L. Hirshfield

    2005-01-01

    High current-density field emission from an array of carbon nanotubes, with field-emission-transistor control, and with secondary electron channel multiplication in a ceramic facing structure, have been combined in a cold cathode for rf guns and diode guns. Electrodynamic and space-charge flow simulations were conducted to specify the cathode configuration and range of emission current density from the field emission cold cathode. Design of this cathode has been made for installation and testing in an existing S-band 2-1/2 cell rf gun. With emission control and modulation, and with current density in the range of 0.1-1 kA/cm2, this cathode could provide performance and long-life not enjoyed by other currently-available cathodes

  15. Supply system with microprocessor control for electron gun

    International Nuclear Information System (INIS)

    Duplin, N.I.; Sergeev, N.N.

    1988-01-01

    Precision supply system for electron gun used in Auger-spectrometer is described. The supply system consists of control and high-voltage parts, made as separate units. Supply high-voltage unit includes system supply module, filament module to supply electron gun cathode and 6 high-volt modules to supply accelerating, modulating and three focusing electrodes of the gun. High-voltage modules have the following characteristics: U-(100-1000)V output voltage, 5x10 -5 U stability, 10 -5 xU pulsation amplitude, J-(0-5)A filament current change range at 10 -4 xJ stability. Control unit including microprocessor, timer and storage devices forms control voltage for all modules and regulates voltage and current of filament at electrodes

  16. Design and remote fiber communication of NSRL electron gun controller

    International Nuclear Information System (INIS)

    Wang Weibing; Gao Hui; Hong Jun; Chen Jun; Wang Guicheng; He Duohui; Chen Gang

    2005-01-01

    A new kind of pulse electron gun controller for 200 MeV LINAC at National Synchrotron Radiation Laboratory was introduced in this paper, including the working principle of the pulse electron gun, the applications of I 2 C serial bus and embedded microcontroller in controlling system. The emphasis is on the hardware design of digital controlled current regulator, digital controlled switch voltage source and high voltage pulse power supply. The software design of fiber communication and PC controlling is also presented. The electron gun controller has successfully been used in NSRL. The result shows that it is quite reliable and the performance is good. This electronic digital system has completely replaced the old mechanical control system. (authors)

  17. High quality flux control system for electron gun evaporation

    International Nuclear Information System (INIS)

    Appelbloom, A.M.; Hadley, P.; van der Marel, D.; Mooij, J.E.

    1991-01-01

    This paper reports on a high quality flux control system for electron gun evaporation developed and tested for the MBE growth of high temperature superconductors. The system can be applied to any electron gun without altering the electron gun itself. Essential elements of the system are a high bandwidth mass spectrometer, control electronics and a high voltage modulator to sweep the electron beam over the melt at high frequencies. the sweep amplitude of the electron beam is used to control the evaporation flux at high frequencies. The feedback loop of the system has a bandwidth of over 100 Hz, which makes it possible to grow superlattices and layered structures in a fast and precisely controlled manner

  18. Design and performance of high uniformity linear filament electron gun

    International Nuclear Information System (INIS)

    Iqbal, Munawar; Fazal-e-Aleem

    2006-01-01

    We describe new features and results from the previously reported [M. Iqbal et al., Rev. Sci. Instrum. 74, 4616 (2003)] thermionic long (up to 140 mm) cathode, electromagnetically focused electron beam gun. The gun which was tested up to 50 kW (5000 mAx10 kV) achieves power density of 33 kW/cm 2 at the target. The cathode temperature and emission current was uniform over a length of 100 mm of the cathode. The beam density profile along the line cathode strongly relates to the temperature distribution along the line cathode. The gun has a remarkable application in heat treatment of large surface area and to coat large substrate surfaces at much faster evaporation rates with lower cost

  19. Jumping the gun: firearms and the mental health of Australians.

    Science.gov (United States)

    Dudley, M; Cantor, C; de Moore, G

    1996-06-01

    The aims of this study were to (i) survey mental health-related correlates of firearms ownership and availability in Australia, and (ii) assess possible causal relationships between civilian gun deaths, gun availability and mental disorders. Available data regarding firearms ownership, injuries and deaths were reviewed as well as studies of (i) gun ownership, suicide and homicide, and (ii) gun control laws and suicide. Findings indicated that 85% of firearm deaths are triggered by distress, as opposed to crime. Most firearm homicides are intrafamilial or involve familiar persons. Firearm suicide rates, although tapering off in recent years, continue to rise among certain groups. It was also found that: (1) Beyond reasonable doubt, a causal relationship exists between gun ownership and firearm suicides and homicides. The role of method substitution is controversial, but is probably less important among the young. (2) Outside the United States, legislation may be useful in reducing firearm and possibly overall suicide rates. (3) If firearm owners are representative of the community, then 15-20% suffer from a psychiatric disorder at any time. While a modest increase in risk of firearms misuse exists for this group, especially those with a history of substance abuse or violence, concern also arises regarding those with mental disorders who access firearms because owners have not secured them. No uniform definition or way of verifying self-reports exists for gun licence applicants regarding these issues. Further regulation of firearm safety and availability is warranted. Public health measures include improved surveillance regarding firearm events, advocacy for appropriate firearm legislation, and better education and communication about firearms.

  20. Low power microwave tests on RF gun prototype of the Iranian Light Source Facility

    Directory of Open Access Journals (Sweden)

    A Sadeghipanah

    2017-08-01

    Full Text Available In this paper, we introduce RF electron gun of Iranian Light Source Facility (ILSF pre-injection system. Design, fabrication and low-power microwave tests results of the prototype RF electron gun have been described in detail. This paper also explains the tuning procedure of the prototype RF electron gun to the desired resonant frequency. The outcomes of this project brighten the path to the fabrication of the RF electron gun by the local industries