WorldWideScience

Sample records for stable function biopsies

  1. Biopsy

    Science.gov (United States)

    ... Oropharynx lesion biopsy Pleural needle biopsy Polyp biopsy Rectal biopsy Renal biopsy Salivary gland biopsy Skin lesion ... Copyright 1997-2018, A.D.A.M., Inc. Duplication for commercial use must be authorized in writing ...

  2. Hepatic mitochondrial function analysis using needle liver biopsy samples.

    Directory of Open Access Journals (Sweden)

    Michael J J Chu

    Full Text Available BACKGROUNDS AND AIM: Current assessment of pre-operative liver function relies upon biochemical blood tests and histology but these only indirectly measure liver function. Mitochondrial function (MF analysis allows direct measurement of cellular metabolic function and may provide an additional index of hepatic health. Conventional MF analysis requires substantial tissue samples (>100 mg obtained at open surgery. Here we report a method to assess MF using <3 mg of tissue obtained by a Tru-cut® biopsy needle making it suitable for percutaneous application. METHODS: An 18G Bard® Max-core® biopsy instrument was used to collect samples. The optimal Tru-cut® sample weight, stability in ice-cold University of Wisconsin solution, reproducibility and protocol utility was initially evaluated in Wistar rat livers then confirmed in human samples. MF was measured in saponin-permeabilized samples using high-resolution respirometry. RESULTS: The average mass of a single rat and human liver Tru-cut® biopsy was 5.60±0.30 and 5.16±0.15 mg, respectively (mean; standard error of mean. Two milligram of sample was found the lowest feasible mass for the MF assay. Tissue MF declined after 1 hour of cold storage. Six replicate measurements within rats and humans (n = 6 each showed low coefficient of variation (<10% in measurements of State-III respiration, electron transport chain (ETC capacity and respiratory control ratio (RCR. Ischemic rat and human liver samples consistently showed lower State-III respiration, ETC capacity and RCR, compared to normal perfused liver samples. CONCLUSION: Consistent measurement of liver MF and detection of derangement in a disease state was successfully demonstrated using less than half the tissue from a single Tru-cut® biopsy. Using this technique outpatient assessment of liver MF is now feasible, providing a new assay for the evaluation of hepatic function.

  3. 26 S proteasomes function as stable entities

    DEFF Research Database (Denmark)

    Hendil, Klavs B; Hartmann-Petersen, Rasmus; Tanaka, Keiji

    2002-01-01

    , shuttles between a free state and the 26-S proteasome, bringing substrate to the complex. However, S5a was not found in the free state in HeLa cells. Besides, all subunits in PA700, including S5a, exchanged at similar low rates. It therefore seems that 26-S proteasomes function as stable entities during...

  4. Persistent organic pollutants and stable isotopes in biopsy samples (2004/2006) from Southern Resident killer whales

    International Nuclear Information System (INIS)

    Krahn, Margaret M.; Hanson, M. Bradley; Baird, Robin W.; Boyer, Richard H.; Burrows, Douglas G.; Emmons, Candice K.; Ford, John K.B.; Jones, Linda L.; Noren, Dawn P.; Ross, Peter S.; Schorr, Gregory S.; Collier, Tracy K.

    2007-01-01

    'Southern Resident' killer whales include three 'pods' (J, K and L) that reside primarily in Puget Sound/Georgia Basin during the spring, summer and fall. This population was listed as 'endangered' in the US and Canada following a 20% decline between 1996 and 2001. The current study, using blubber/epidermis biopsy samples, contributes contemporary information about potential factors (i.e., levels of pollutants or changes in diet) that could adversely affect Southern Residents. Carbon and nitrogen stable isotopes indicated J- and L-pod consumed prey from similar trophic levels in 2004/2006 and also showed no evidence for a large shift in the trophic level of prey consumed by L-pod between 1996 and 2004/2006. ΣPCBs decreased for Southern Residents biopsied in 2004/2006 compared to 1993-1995. Surprisingly, however, a three-year-old male whale (J39) had the highest concentrations of ΣPBDEs, ΣHCHs and HCB. POP ratio differences between J- and L-pod suggested that they occupy different ranges in winter

  5. Persistent organic pollutants and stable isotopes in biopsy samples (2004/2006) from Southern Resident killer whales

    Energy Technology Data Exchange (ETDEWEB)

    Krahn, Margaret M. [NOAA Fisheries, Northwest Fisheries Science Center, 2725 Montlake Boulevard East, Seattle, WA 98112 (United States)], E-mail: peggy.krahn@noaa.gov; Hanson, M. Bradley [NOAA Fisheries, Northwest Fisheries Science Center, 2725 Montlake Boulevard East, Seattle, WA 98112 (United States); Baird, Robin W. [Cascadia Research, 218 1/2 W, 4th Avenue, Olympia, WA 98501 (United States); Boyer, Richard H.; Burrows, Douglas G.; Emmons, Candice K. [NOAA Fisheries, Northwest Fisheries Science Center, 2725 Montlake Boulevard East, Seattle, WA 98112 (United States); Ford, John K.B. [Fisheries and Oceans Canada, Pacific Biological Station, Nanaimo, BC, V9R 5K6 (Canada); Jones, Linda L.; Noren, Dawn P. [NOAA Fisheries, Northwest Fisheries Science Center, 2725 Montlake Boulevard East, Seattle, WA 98112 (United States); Ross, Peter S. [Fisheries and Oceans Canada, Institute of Ocean Sciences, P.O. Box 6000, Sidney, BC, V8L 4B2 (Canada); Schorr, Gregory S. [Cascadia Research, 218 1/2 W, 4th Avenue, Olympia, WA 98501 (United States); Collier, Tracy K. [NOAA Fisheries, Northwest Fisheries Science Center, 2725 Montlake Boulevard East, Seattle, WA 98112 (United States)

    2007-12-15

    'Southern Resident' killer whales include three 'pods' (J, K and L) that reside primarily in Puget Sound/Georgia Basin during the spring, summer and fall. This population was listed as 'endangered' in the US and Canada following a 20% decline between 1996 and 2001. The current study, using blubber/epidermis biopsy samples, contributes contemporary information about potential factors (i.e., levels of pollutants or changes in diet) that could adversely affect Southern Residents. Carbon and nitrogen stable isotopes indicated J- and L-pod consumed prey from similar trophic levels in 2004/2006 and also showed no evidence for a large shift in the trophic level of prey consumed by L-pod between 1996 and 2004/2006. {sigma}PCBs decreased for Southern Residents biopsied in 2004/2006 compared to 1993-1995. Surprisingly, however, a three-year-old male whale (J39) had the highest concentrations of {sigma}PBDEs, {sigma}HCHs and HCB. POP ratio differences between J- and L-pod suggested that they occupy different ranges in winter.

  6. Functional quality of MR-compatible automatic biopsy guns compared with conventional ferromagnetic biopsy systems. An in vitro study

    International Nuclear Information System (INIS)

    Langen, H.J.; Landwehr, P.

    2001-01-01

    Comparative evaluation of specimens obtained with different MR-compatible biopsy systems and a conventional ferromagnetic system. Methods: Biopsies of a pig liver were performed post-mortem with three different MR-compatible (Somatex; E-Z-EM; Daum) and one conventional biopsy system (Somatex), five with each device. The specimens were measured and the histopathological quality was graded on a scale from 0 (no tissue) to 9 (best). The tip of the needle was examined with an electron microscope before and after biopsy to demonstrate abrasion. Results: The histopathological score between the first and fifth specimen taken with one biopsy device showed no significant difference. The conventional system yielded significantly better results in nearly all categories (p 2 ) were significantly smaller than those from the conventional system (9.98 mm 2 ). The needle tip abrasion of the different biopsy systems determined by electron microscopy showed no substantial difference. (orig.) [de

  7. Bias-corrected estimation of stable tail dependence function

    DEFF Research Database (Denmark)

    Beirlant, Jan; Escobar-Bach, Mikael; Goegebeur, Yuri

    2016-01-01

    We consider the estimation of the stable tail dependence function. We propose a bias-corrected estimator and we establish its asymptotic behaviour under suitable assumptions. The finite sample performance of the proposed estimator is evaluated by means of an extensive simulation study where...

  8. On the likelihood function of Gaussian max-stable processes

    KAUST Repository

    Genton, M. G.; Ma, Y.; Sang, H.

    2011-01-01

    We derive a closed form expression for the likelihood function of a Gaussian max-stable process indexed by ℝd at p≤d+1 sites, d≥1. We demonstrate the gain in efficiency in the maximum composite likelihood estimators of the covariance matrix from p=2 to p=3 sites in ℝ2 by means of a Monte Carlo simulation study. © 2011 Biometrika Trust.

  9. On the likelihood function of Gaussian max-stable processes

    KAUST Repository

    Genton, M. G.

    2011-05-24

    We derive a closed form expression for the likelihood function of a Gaussian max-stable process indexed by ℝd at p≤d+1 sites, d≥1. We demonstrate the gain in efficiency in the maximum composite likelihood estimators of the covariance matrix from p=2 to p=3 sites in ℝ2 by means of a Monte Carlo simulation study. © 2011 Biometrika Trust.

  10. Macromolecular surface design: photopatterning of functional stable nitrile oxides.

    Science.gov (United States)

    Altintas, Ozcan; Glassner, Mathias; Rodriguez-Emmenegger, Cesar; Welle, Alexander; Trouillet, Vanessa; Barner-Kowollik, Christopher

    2015-05-04

    The efficient trapping of photogenerated thioaldehydes with functional shelf-stable nitrile oxides in a 1,3-dipolar cycloaddition is a novel and versatile photochemical strategy for polymer end-group functionalization and surface modification under mild and equimolar conditions. The modular ligation in solution was followed in detail by electrospray ionization mass spectrometry (ESI-MS). X-ray photoelectron spectroscopy (XPS) was employed to analyze the functionalized surfaces, whereas time-of-flight secondary-ion mass spectrometry (ToF-SIMS) confirmed the spatial control of the surface functionalization using a micropatterned shadow mask. Polymer brushes were grown from the surface in a spatially confined regime by surface-initiated atom transfer radical polymerization (SI-ATRP) as confirmed by TOF-SIMS, XPS as well as ellipsometry. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Biological factors of natural and artificial ecosystems stable (unstable) functioning

    Science.gov (United States)

    Pechurkin, Nikolai S.

    The problem of sustainable development of humanity on Earth and the problem of supporting human life in space have the same scientific and methodological bases. The key to solve both problems is a long term maintenance of balanced material cycle. As a whole, natural or artificial ecosystems are to be more closed than open, but their elements (links of systems) are to be substantially open in interactions with each other. Prolonged stable interactions of different links have to have unique joint results - closed material cycling or biotic turnover. It is necessary to include, at least, three types of main links into any system to support real material cycling: producers, consumers, reducers. Producer links are now under studies in many laboratories. It is evident that the higher productivity of link, the lower link stability. Especially, it concerns with parasite impact to plants. As usual, artificial ecosystems are more simple (incomplete) than natural ecosystems, sometimes, they have not enough links for prolonged stable functioning. For example, life support system for space flight can be incomplete in consumer link, having only some crew persons, instead of interacting populations of consumers. As for reducer link, it is necessary to "organize" a special coordinated work of microbial biocenoses to fulfill proper cycling. Possible evolution of links, their self development is a matter of special attention for the maintenance of prolonged stable functioning. It's the most danger for systems with populations of quickly reproducing, so-called, R - strategists, according to symbols of logistic equation. From another side, quick reproduction of R - strategists is able to increase artificial ecosystems and their links functioning. After some damages of system, R - strategist's link can be quickly "self repaired" up to level of normal functioning. Some experimental data of this kind and mathematical models are to be discussed in the paper. This work is supported by

  12. Can pre-implantation biopsies predict renal allograft function in pediatric renal transplant recipients?

    Directory of Open Access Journals (Sweden)

    Jameela A. Kari

    2015-11-01

    Full Text Available Objectives: To determine the utility of pre-implantation renal biopsy (PIB to predict renal allograft outcomes. Methods: This is a retrospective review of all patients that underwent PIB from January 2003 to December 2011 at the Great Ormond Street Hospital for Children in London, United Kingdom. Thirty-two male patients (56% aged 1.5-16 years (median: 10.2 at the time of transplantation were included in the study and followed-up for 33 (6-78 months. The results were compared with 33 controls. Results: The PIB showed normal histopathological findings in 13 patients (41%, mild chronic vascular changes in 8 (25%, focal tubular atrophy in one, moderate to severe chronic vascular change in 3, mild to moderate acute tubular damage in 6, and tissue was inadequate in one subject. Delayed graft function (DGF was observed in 3 patients; 2 with vascular changes in PIB, and one with normal histopathological findings. Two subjects with PIB changes lost their grafts. The estimated glomerular filtration rate at 3-, and 6-months post-transplantation was lower in children with abnormal PIB changes compared with those with normal PIB. There was one case of DGF in the control group, and 4 children lost their grafts including the one with DGF. Conclusion: Pre-implantation renal biopsy can provide important baseline information of the graft with implications on subsequent medical treatment for pediatric renal transplant recipients.

  13. Intraoperative visualisation of functional structures facilitates safe frameless stereotactic biopsy in the motor eloquent regions of the brain.

    Science.gov (United States)

    Zhang, Jia-Shu; Qu, Ling; Wang, Qun; Jin, Wei; Hou, Yuan-Zheng; Sun, Guo-Chen; Li, Fang-Ye; Yu, Xin-Guang; Xu, Ban-Nan; Chen, Xiao-Lei

    2017-12-20

    For stereotactic brain biopsy involving motor eloquent regions, the surgical objective is to enhance diagnostic yield and preserve neurological function. To achieve this aim, we implemented functional neuro-navigation and intraoperative magnetic resonance imaging (iMRI) into the biopsy procedure. The impact of this integrated technique on the surgical outcome and postoperative neurological function was investigated and evaluated. Thirty nine patients with lesions involving motor eloquent structures underwent frameless stereotactic biopsy assisted by functional neuro-navigation and iMRI. Intraoperative visualisation was realised by integrating anatomical and functional information into a navigation framework to improve biopsy trajectories and preserve eloquent structures. iMRI was conducted to guarantee the biopsy accuracy and detect intraoperative complications. The perioperative change of motor function and biopsy error before and after iMRI were recorded, and the role of functional information in trajectory selection and the relationship between the distance from sampling site to nearby eloquent structures and the neurological deterioration were further analyzed. Functional neuro-navigation helped modify the original trajectories and sampling sites in 35.90% (16/39) of cases to avoid the damage of eloquent structures. Even though all the lesions were high-risk of causing neurological deficits, no significant difference was found between preoperative and postoperative muscle strength. After data analysis, 3mm was supposed to be the safe distance for avoiding transient neurological deterioration. During surgery, the use of iMRI significantly reduced the biopsy errors (p = 0.042) and potentially increased the diagnostic yield from 84.62% (33/39) to 94.87% (37/39). Moreover, iMRI detected intraoperative haemorrhage in 5.13% (2/39) of patients, all of them benefited from the intraoperative strategies based on iMRI findings. Intraoperative visualisation of

  14. Electropolishing of Stainless Steel Implants for Stable Functional Osteosynthesis

    Directory of Open Access Journals (Sweden)

    Omel’chuk, A.О.

    2016-01-01

    Full Text Available A new method for the electropolishing stainless steel for stable functional osteosynthesis has been developed. The polishing of implants was carried out in solutions, based on the ternary system H2SO4—H3PO4—H2O with stepwise decreasing the current density and increasing the orthophosphoric acid concentration. The optimal polishing conditions (current density, solution composition, temperature and duration have been determined. The developed method improves the quality and mechanical properties of the surface.

  15. Liver biopsy

    Science.gov (United States)

    Biopsy - liver; Percutaneous biopsy ... the biopsy needle to be inserted into the liver. This is often done by using ultrasound. The ... the chance of damage to the lung or liver. The needle is removed quickly. Pressure will be ...

  16. Relationship between histopathological changes in post partum renal biopsies and renal function tests of African women with early onset pre-eclampsia.

    Science.gov (United States)

    Khedun, S M; Naicker, T; Moodley, J

    2000-05-01

    To improve the diagnostic accuracy of concurrent renal disease in hypertension of pregnancy, biopsy evaluation is essential. In addition, establishing underlying renal disease is important for prognosis on future pregnancies. We therefore designed a study to determine the diagnostic yield of postpartum renal biopsy and the nature and frequency of complications associated with this procedure. Also, to determine relationships, if any, between renal function tests and ultrastructural and histopathological findings. Fifty renal biopsies were performed in the immediate postpartum period in black African women with early onset pre-eclampsia. Each biopsy specimen was placed in a separate container and coded so that sampling was unknown to the electron microscopist. Each biopsy specimen was divided into three parts, and processed and stained for light, fluorescent and transmission electron microscopy using conventional techniques. Renal tissue biopsies were adequate for diagnostic purposes in all cases. There were no complications in any of the 50 patients studied. Ultrastructural examination confirmed the light microscopy findings. In addition the ultrastructural findings showed intramembranous deposits, foot process fusion and mesangial deposits. In 16 patients with normal renal function tests; the biopsies evaluation from these patients showed ultrastructural changes. In the remaining 34 patients with abnormal renal function tests of varying severity; biopsy evaluation from these patients showed both ultrastructural and histopathological changes. Renal biopsy procedure is safe, and ultrastructural and histological findings obtained from postpartum renal biopsies are more informative than the routine renal function tests.

  17. Stable isotope views on ecosystem function: challenging or challenged?

    Science.gov (United States)

    Resco, Víctor; Querejeta, José I; Ogle, Kiona; Voltas, Jordi; Sebastià, Maria-Teresa; Serrano-Ortiz, Penélope; Linares, Juan C; Moreno-Gutiérrez, Cristina; Herrero, Asier; Carreira, José A; Torres-Cañabate, Patricia; Valladares, Fernando

    2010-06-23

    Stable isotopes and their potential for detecting various and complex ecosystem processes are attracting an increasing number of scientists. Progress is challenging, particularly under global change scenarios, but some established views have been challenged. The IX meeting of the Spanish Association of Terrestrial Ecology (AAET, Ubeda, 18-22 October 2009) hosted a symposium on the ecology of stable isotopes where the linear mixing model approach of partitioning sinks and sources of carbon and water fluxes within an ecosystem was challenged, and new applications of stable isotopes for the study of plant interactions were evaluated. Discussion was also centred on the need for networks that monitor ecological processes using stable isotopes and key ideas for fostering future research with isotopes.

  18. Stable isotope views on ecosystem function: challenging or challenged?

    Science.gov (United States)

    Resco, Víctor; Querejeta, José I.; Ogle, Kiona; Voltas, Jordi; Sebastià, Maria-Teresa; Serrano-Ortiz, Penélope; Linares, Juan C.; Moreno-Gutiérrez, Cristina; Herrero, Asier; Carreira, José A.; Torres-Cañabate, Patricia; Valladares, Fernando

    2010-01-01

    Stable isotopes and their potential for detecting various and complex ecosystem processes are attracting an increasing number of scientists. Progress is challenging, particularly under global change scenarios, but some established views have been challenged. The IX meeting of the Spanish Association of Terrestrial Ecology (AAET, Úbeda, 18–22 October 2009) hosted a symposium on the ecology of stable isotopes where the linear mixing model approach of partitioning sinks and sources of carbon and water fluxes within an ecosystem was challenged, and new applications of stable isotopes for the study of plant interactions were evaluated. Discussion was also centred on the need for networks that monitor ecological processes using stable isotopes and key ideas for fostering future research with isotopes. PMID:20015858

  19. High-resolution respirometry of fine-needle muscle biopsies in pre-manifest Huntington's disease expansion mutation carriers shows normal mitochondrial respiratory function.

    Directory of Open Access Journals (Sweden)

    Eva Buck

    Full Text Available Alterations in mitochondrial respiration are an important hallmark of Huntington's disease (HD, one of the most common monogenetic causes of neurodegeneration. The ubiquitous expression of the disease causing mutant huntingtin gene raises the prospect that mitochondrial respiratory deficits can be detected in skeletal muscle. While this tissue is readily accessible in humans, transgenic animal models offer the opportunity to cross-validate findings and allow for comparisons across organs, including the brain. The integrated respiratory chain function of the human vastus lateralis muscle was measured by high-resolution respirometry (HRR in freshly taken fine-needle biopsies from seven pre-manifest HD expansion mutation carriers and nine controls. The respiratory parameters were unaffected. For comparison skeletal muscle isolated from HD knock-in mice (HdhQ111 as well as a broader spectrum of tissues including cortex, liver and heart muscle were examined by HRR. Significant changes of mitochondrial respiration in the HdhQ knock-in mouse model were restricted to the liver and the cortex. Mitochondrial mass as quantified by mitochondrial DNA copy number and citrate synthase activity was stable in murine HD-model tissue compared to control. mRNA levels of key enzymes were determined to characterize mitochondrial metabolic pathways in HdhQ mice. We demonstrated the feasibility to perform high-resolution respirometry measurements from small human HD muscle biopsies. Furthermore, we conclude that alterations in respiratory parameters of pre-manifest human muscle biopsies are rather limited and mirrored by a similar absence of marked alterations in HdhQ skeletal muscle. In contrast, the HdhQ111 murine cortex and liver did show respiratory alterations highlighting the tissue specific nature of mutant huntingtin effects on respiration.

  20. Prostate biopsy

    Science.gov (United States)

    ... give the cells a grade called a Gleason score . This helps predict how fast the cancer will ... TRUS); Stereotactic transperineal prostate biopsy (STPB) Images Male reproductive anatomy References Babayan RK, Katz MH. Biopsy prophylaxis, ...

  1. Kidney biopsy

    Science.gov (United States)

    ... the kidney (in rare cases, may require a blood transfusion) Bleeding into the muscle, which might cause soreness Infection (small risk) Alternative Names Renal biopsy; Biopsy - kidney Images Kidney anatomy ...

  2. On the existence of polynomial Lyapunov functions for rationally stable vector fields

    DEFF Research Database (Denmark)

    Leth, Tobias; Wisniewski, Rafal; Sloth, Christoffer

    2018-01-01

    This paper proves the existence of polynomial Lyapunov functions for rationally stable vector fields. For practical purposes the existence of polynomial Lyapunov functions plays a significant role since polynomial Lyapunov functions can be found algorithmically. The paper extents an existing result...... on exponentially stable vector fields to the case of rational stability. For asymptotically stable vector fields a known counter example is investigated to exhibit the mechanisms responsible for the inability to extend the result further....

  3. Stable Nafion-functionalized graphene dispersions for transparent conducting films

    International Nuclear Information System (INIS)

    Liu Yangqiao; Gao Lian; Sun Jing; Wang Yan; Zhang Jing

    2009-01-01

    Nafion was used for the first time to aid in preparing stable graphene dispersions in mixed water/ethanol (1:1) solvents via the reduction of graphite oxide using hydrazine. The dispersion was characterized by ultraviolet-visible (UV-vis) spectra, transmission electron microscopy, zeta potential analysis, etc. It was found that for Nafion-to-graphene ratios higher than 5:1, graphene solutions with concentrations up to 1 mg ml -1 and stabilities of over three months were obtained. It was proposed that the Nafion adsorbed onto the graphene by the hydrophobic interaction of its fluoro-backbones with the graphene layer and imparted stability by an electrosteric mechanism. Furthermore, transparent and conductive films were prepared using these highly stable Nafion-stabilized graphene dispersions. The prepared Nafion-graphene films possess smooth and homogeneous surfaces and the sheet resistance was as low as 30 kΩ/sq for a transmittance of 80% at 550 nm, which was much lower than for other graphene films obtained by chemical reduction. X-ray photoelectron spectroscopy and Raman spectroscopy confirmed the p-doping of the graphene by Nafion. It was expected that this p-doping effect, as well as the high dispersing ability of Nafion for graphene and the connection of the sp 2 domains by residual Nafion combined to produce good properties of the Nafion-graphene films.

  4. Cold knife cone biopsy

    Science.gov (United States)

    ... biopsy; Pap smear - cone biopsy; HPV - cone biopsy; Human papilloma virus - cone biopsy; Cervix - cone biopsy; Colposcopy - cone biopsy Images Female reproductive anatomy Cold cone biopsy Cold cone removal References Baggish ...

  5. Liver function tests using the stable istope 15N

    International Nuclear Information System (INIS)

    Faust, H.; Jung, K.; Hirschberg, K.; Krumbiegel, P.; Junghans, P.; Reinhardt, R.; Teichmann, B.

    1988-01-01

    Several liver function tests using oral application of a nitrogen compound labelled with 15 N and the subsequent determination of 15 N in a certain fraction of urine or in the total urine by emission spectrometry are described. Because of the key function of the liver in the metabolism of nitrogen compounds, the results of these tests allow conclusions concerning some disturbances of liver functions. (author)

  6. Liver function tests using the stable isotope /sup 15/N

    Energy Technology Data Exchange (ETDEWEB)

    Faust, H; Jung, K; Hirschberg, K; Krumbiegel, P; Junghans, P; Reinhardt, R; Matkowitz, R; Teichmann, B

    1988-01-01

    Several liver function tests using oral application of a nitrogen compound labelled with /sup 15/N and the subsequent determination of /sup 15/N in a certain fraction of urine or in the total urine by emission spectrometry are described. Because of the key function of the liver in the metabolism of nitrogen compounds, the results of these tests allow conclusions concerning some disturbances of liver functions.

  7. High taxonomic variability despite stable functional structure across microbial communities.

    Science.gov (United States)

    Louca, Stilianos; Jacques, Saulo M S; Pires, Aliny P F; Leal, Juliana S; Srivastava, Diane S; Parfrey, Laura Wegener; Farjalla, Vinicius F; Doebeli, Michael

    2016-12-05

    Understanding the processes that are driving variation of natural microbial communities across space or time is a major challenge for ecologists. Environmental conditions strongly shape the metabolic function of microbial communities; however, other processes such as biotic interactions, random demographic drift or dispersal limitation may also influence community dynamics. The relative importance of these processes and their effects on community function remain largely unknown. To address this uncertainty, here we examined bacterial and archaeal communities in replicate 'miniature' aquatic ecosystems contained within the foliage of wild bromeliads. We used marker gene sequencing to infer the taxonomic composition within nine metabolic functional groups, and shotgun environmental DNA sequencing to estimate the relative abundances of these groups. We found that all of the bromeliads exhibited remarkably similar functional community structures, but that the taxonomic composition within individual functional groups was highly variable. Furthermore, using statistical analyses, we found that non-neutral processes, including environmental filtering and potentially biotic interactions, at least partly shaped the composition within functional groups and were more important than spatial dispersal limitation and demographic drift. Hence both the functional structure and taxonomic composition within functional groups of natural microbial communities may be shaped by non-neutral and roughly separate processes.

  8. Further Stable methods for the calculation of partition functions

    International Nuclear Information System (INIS)

    Wilson, B G; Gilleron, F; Pain, J

    2007-01-01

    The extension to recursion over holes of the Gilleron and Pain method for calculating partition functions of a canonical ensemble of non-interacting bound electrons is presented as well as a generalization for the efficient computation of collisional line broadening

  9. Significant association between renal function and amyloid-positive area in renal biopsy specimens in AL amyloidosis

    Directory of Open Access Journals (Sweden)

    Kuroda Takeshi

    2012-09-01

    Full Text Available Abstract Background The kidney is a major target organ for systemic amyloidosis that often affects the kidney including proteinura, and elevated serum creatinine (Cr. The correlation between amount of amyloid deposits and clinical parameters is not known. The aim of this study was to clarify correlation the amyloid area in all renal biopsy specimen and clinical parameters. Methods Fifty-eight patients with an established diagnosis of AL amyloidosis participated in the study. All patients showed amyloid deposits in renal biopsies. We retrospectively investigated the correlation between clinical data and amyloid occupied area in whole renal biopsy specimens. Results The area occupied by amyloid was less than 10% in 57 of the 58 patients, and was under 2% in 40. For statistical analyses, %amyloid-positive areas were transformed to common logarithmic values (Log10%amyloid. Cr showed significant correlation with Log10%amyloid and estimated glomerular filtration rate (eGFR showed the significant negative correlation. Patient age, cleatinine clearance (Ccr, blood urea nitorogen, and urinary protein was not significantly correlated with Log10%amyloid. The correlation with other clinical factors such as sex, and serum concentrations of total protein, albumin, immunoglobulins, compliments was evaluated. None of these factors significantly correlated with Log10%amyloid. According to sex- and age- adjusted multiple linear regression analysis, Log10%amyloid had significant positive association with Cr and significant negative association with eGFR. Conclusion There is significant association between amyloid-positive area in renal tissue and renal function, especially Cr and eGFR. The level of Cr and eGFR may be a marker of amount of amyloid in renal tissue.

  10. Muscle biopsies from human muscle diseases with myopathic pathology reveal common alterations in mitochondrial function.

    Science.gov (United States)

    Sunitha, Balaraju; Gayathri, Narayanappa; Kumar, Manish; Keshava Prasad, Thottethodi Subrahmanya; Nalini, Atchayaram; Padmanabhan, Balasundaram; Srinivas Bharath, Muchukunte Mukunda

    2016-07-01

    Muscle diseases are clinically and genetically heterogeneous and manifest as dystrophic, inflammatory and myopathic pathologies, among others. Our previous study on the cardiotoxin mouse model of myodegeneration and inflammation linked muscle pathology with mitochondrial damage and oxidative stress. In this study, we investigated whether human muscle diseases display mitochondrial changes. Muscle biopsies from muscle disease patients, represented by dysferlinopathy (dysfy) (dystrophic pathology; n = 43), polymyositis (PM) (inflammatory pathology; n = 24), and distal myopathy with rimmed vacuoles (DMRV) (distal myopathy; n = 31) were analyzed. Mitochondrial damage (ragged blue and COX-deficient fibers) was revealed in dysfy, PM, and DMRV cases by enzyme histochemistry (SDH and COX-SDH), electron microscopy (vacuolation and altered cristae) and biochemical assays (significantly increased ADP/ATP ratio). Proteomic analysis of muscle mitochondria from all three muscle diseases by isobaric tag for relative and absolute quantitation labeling and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis demonstrated down-regulation of electron transport chain (ETC) complex subunits, assembly factors and Krebs cycle enzymes. Interestingly, 80 of the under-expressed proteins were common among the three pathologies. Assay of ETC and Krebs cycle enzyme activities validated the MS data. Mitochondrial proteins from muscle pathologies also displayed higher tryptophan (Trp) oxidation and the same was corroborated in the cardiotoxin model. Molecular modeling predicted Trp oxidation to alter the local structure of mitochondrial proteins. Our data highlight mitochondrial alterations in muscle pathologies, represented by morphological changes, altered mitochondrial proteome and protein oxidation, thereby establishing the role of mitochondrial damage in human muscle diseases. We investigated whether human muscle diseases display mitochondrial changes. Muscle biopsies

  11. Predisposing factors of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy: comparison between CT emphysema score and pulmonary function test

    International Nuclear Information System (INIS)

    Lee, Chang Ho; Park, Kyung Joo; Park, Dong Won; Jung, Kyung Il; Suh, Jung Ho

    1997-01-01

    To compare the CT emphysema score with various factors of pulmonary function test by simple spirometry and to use the result as a predictor of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy. The CT scans of 106 patients who had undergone percutaneous transthoracic fine needle aspiration biopsy of lung lesions within the previous 18 months were retrospectively reviewed. In 75 of these 106 cases, the results of the pulmonary function test were also reviewed. On plain chest radiography, pneumothorax was noted in 20 cases (19%). Emphysema was blindly evaluated. We divided each lung into four segments and determined the severity and involved volume of emphysema, as seen on CT. Severity was classified as one of four grades, as follow : absence of emphysema=0 ; low attenuation area of less than 5mm=1 ; low attenuation area of more than 5mm, and vascular pruning with normal lung intervening=2 ; and diffuse low attenuation without intervening normal lung, and larger confluent low attenuation with vascular pruning and distortion of branching pattern occupying all or almost all the involved parenchyma=3. The involved area was also classified as one of four grades : less than 25%=1 ; 25 - 49%=2 ; 51 - 74%=3 ; and more than 75%=4. The CT emphysema score was defined as the average of the grade of severity multiplied by the grade of involved area. Pulmonary function tests, consisting of simple spirometry and a pulmonologist's interpretation, were evaluated. We also evaluated depth and size of lesion as known predisposing factors in postbioptic pneumothorax. Statistical analysis was performed using the chi-square test, Wilcoxon ranks sum W test and the student t test. A comparison between the two groups of occurrence(with or without pneumothorax) showed the emphysema scores to be 1.69±2.0 and 1.11±2.9, respectively ; there was thus no significant difference between the two groups (z= - 0.048, p>0.10). Nor were differences revealed by the pulmonary

  12. Predisposing factors of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy: comparison between CT emphysema score and pulmonary function test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Ho; Park, Kyung Joo; Park, Dong Won; Jung, Kyung Il; Suh, Jung Ho [Ajou Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-11-01

    To compare the CT emphysema score with various factors of pulmonary function test by simple spirometry and to use the result as a predictor of pneumothorax in percutaneous transthoracic fine needle aspiration biopsy. The CT scans of 106 patients who had undergone percutaneous transthoracic fine needle aspiration biopsy of lung lesions within the previous 18 months were retrospectively reviewed. In 75 of these 106 cases, the results of the pulmonary function test were also reviewed. On plain chest radiography, pneumothorax was noted in 20 cases (19%). Emphysema was blindly evaluated. We divided each lung into four segments and determined the severity and involved volume of emphysema, as seen on CT. Severity was classified as one of four grades, as follow : absence of emphysema=0 ; low attenuation area of less than 5mm=1 ; low attenuation area of more than 5mm, and vascular pruning with normal lung intervening=2 ; and diffuse low attenuation without intervening normal lung, and larger confluent low attenuation with vascular pruning and distortion of branching pattern occupying all or almost all the involved parenchyma=3. The involved area was also classified as one of four grades : less than 25%=1 ; 25 - 49%=2 ; 51 - 74%=3 ; and more than 75%=4. The CT emphysema score was defined as the average of the grade of severity multiplied by the grade of involved area. Pulmonary function tests, consisting of simple spirometry and a pulmonologist's interpretation, were evaluated. We also evaluated depth and size of lesion as known predisposing factors in postbioptic pneumothorax. Statistical analysis was performed using the chi-square test, Wilcoxon ranks sum W test and the student t test. A comparison between the two groups of occurrence(with or without pneumothorax) showed the emphysema scores to be 1.69{+-}2.0 and 1.11{+-}2.9, respectively ; there was thus no significant difference between the two groups (z= - 0.048, p>0.10). Nor were differences revealed by the

  13. Liver Biopsy

    Science.gov (United States)

    ... called if any of the following occur: ● Persistent abdominal or chest pain ● Vomiting ● Pallor, weakness or dizziness ● Bleeding from the site of the biopsy ● Passage of tarry black stools For more information or to locate a pediatric gastroen- terologist in your area please visit our ...

  14. Nail biopsy: A user's manual

    Directory of Open Access Journals (Sweden)

    Chander Grover

    2018-01-01

    Full Text Available Nail biopsy is a procedure not routinely resorted to; but when indicated, it is often the only clue left for diagnosis. At such times, it pays to be conversant with it. It is an investigation that not only provides etiologic, diagnostic, and prognostic information but also aids in understanding the pathogenesis of nail diseases. It can be of therapeutic value, especially with respect to nail tumors. This article compiles the procedural techniques for nail biopsy of various types and attempts to summarize the evidence available in the literature. The objective of nail biopsy is to clinch a precise diagnosis of nail pathology with a simple and safe surgical procedure, avoiding pain or permanent nail damage. Patient selection is of utmost importance, wherein, the patient does not have typical skin lesions, yields inadequate information on routine nail investigations, and has no peripheral vascular compromise. The patient needs to be explained about the risks associated, the expected functional handicap, the time required for regrowth, a possibility of permanent nail dystrophy, and a possibility of not achieving a diagnosis even after the biopsy. Techniques and types of various nail biopsies are being discussed in this article. The specimen could be collected as an excision biopsy, punch biopsy, shave biopsy, or longitudinal biopsy. The trick lies in choosing the appropriate area for biopsy. Various biopsy types discussed in this article include nail plate biopsy (easiest and least scarring; nail bed biopsy (elliptical excision or punch; nail matrix biopsy (elliptical excision, punch excision (≤3 mm or tangential/shave excision; and nail fold biopsy. Complications reported along with means to minimize them are also discussed.

  15. Histopathological analysis of pre-implantation donor kidney biopsies: association with graft survival and function in one year post-transplantation

    Directory of Open Access Journals (Sweden)

    Karla Lais Pêgas

    2014-04-01

    Full Text Available Introduction: Pre-implantation kidney biopsy is a decision-making tool when considering the use of grafts from deceased donors with expanded criteria, implanting one or two kidneys and comparing this to post-transplantation biopsies. The role of histopathological alterations in kidney compartments as a prognostic factor in graft survival and function has had conflicting results. Objective: This study evaluated the prevalence of chronic alterations in pre-implant biopsies of kidney grafts and the association of findings with graft function and survival in one year post-transplant. Methods: 110 biopsies were analyzed between 2006 and 2009 at Santa Casa de Porto Alegre, including live donors, ideal deceased donors and those with expanded criteria. The score was computed according to criteria suggested by Remuzzi. The glomerular filtration rate (GFR was calculated using the abbreviated MDRD formula. Results: No statistical difference was found in the survival of donors stratified according to Remuzzi criteria. The GFR was significantly associated with the total scores in the groups with mild and moderate alterations, and in the kidney compartments alone, by univariate analysis. The multivariate model found an association with the presence of arteriosclerosis, glomerulosclerosis, acute rejection and delayed graft function. Conclusion: Pre-transplant chronic kidney alterations did not influence the post-transplantation one-year graft survival, but arteriosclerosis and glomerulosclerosis is predictive of a worse GFR. Delayed graft function and acute rejection are independent prognostic factors.

  16. Highly thermal-stable and functional cellulose nanocrystals and nanofibrils produced using fully recyclable organic acids

    Science.gov (United States)

    Liheng Chen; Junyong Zhu; Carlos Baez; Peter Kitin; Thomas Elder

    2016-01-01

    Here we report the production of highly thermal stable and functional cellulose nanocrystals (CNC) and nanofibrils (CNF) by hydrolysis using concentrated organic acids. Due to their low water solubility, these solid organic acids can be easily recovered after hydrolysis reactions through crystallization at a lower or ambient temperature. When dicarboxylic acids were...

  17. Pseudosatellite technologies based on the use of functionally stable complexes of remote-piloted aircrafts

    Science.gov (United States)

    Mashkov, O. A.; Samborskiy, I. I.

    2009-10-01

    A bundle of papers dealing with functionally stable systems requires the necessity of analyzing of obtained results and their understanding in a general context of cybernetic's development and applications. Description of this field of science, main results and perspectives of the new theory of functionally stability of dynamical systems concerning the problem of remote-piloted aircrafts engineering using pseudosatellite technologies are proposed in the paper.

  18. THE COVARIATION FUNCTION FOR SYMMETRIC &ALPHA;-STABLE RANDOM VARIABLES WITH FINITE FIRST MOMENTS

    Directory of Open Access Journals (Sweden)

    Dedi Rosadi

    2012-05-01

    Full Text Available In this paper, we discuss a generalized dependence measure which is designed to measure dependence of two symmetric α-stable random variables with finite mean(1<α<=2 and contains the covariance function as the special case (when α=2. Weshortly discuss some basic properties of the function and consider several methods to estimate the function and further investigate the numerical properties of the estimatorusing the simulated data. We show how to apply this function to measure dependence of some stock returns on the composite index LQ45 in Indonesia Stock Exchange.

  19. Sleep Disturbance, Daytime Symptoms, and Functional Performance in Patients With Stable Heart Failure: A Mediation Analysis.

    Science.gov (United States)

    Jeon, Sangchoon; Redeker, Nancy S

    2016-01-01

    Sleep disturbance is common among patients with heart failure (HF) who also experience symptom burden and poor functional performance. We evaluated the extent to which sleep-related, daytime symptoms (fatigue, excessive daytime sleepiness, and depressive symptoms) mediate the relationship between sleep disturbance and functional performance among patients with stable HF. We recruited patients with stable HF for this secondary analysis of data from a cross-sectional, observational study. Participants completed unattended ambulatory polysomnography from which the Respiratory Disturbance Index was calculated, along with a Six-Minute Walk Test, questionnaires to elicit sleep disturbance (Pittsburgh Sleep Quality Index, Insomnia Symptoms from the Sleep Habits Questionnaire), daytime symptoms (Center for Epidemiologic Studies Depression Scale, Global Fatigue Index, Epworth Sleepiness Scale), and self-reported functional performance (Medical Outcomes Study SF36 V2 Physical Function Scale). We used structural equation modeling with latent variables for the key analysis. Follow-up, exploratory regression analysis with bootstrapped samples was used to examine the extent to which individual daytime symptoms mediated effects of sleep disturbance on functional performance after controlling for clinical and demographic covariates. The sample included 173 New York Heart Association Class I-IV HF patients (n = 60/34.7% women; M = 60.7, SD = 16.07 years of age). Daytime symptoms mediated the relationship between sleep disturbance and functional performance. Fatigue and depression mediated the relationship between insomnia symptoms and self-reported functional performance, whereas fatigue and sleepiness mediated the relationship between sleep quality and functional performance. Sleepiness mediated the relationship between the respiratory index and self-reported functional performance only in people who did not report insomnia. Daytime symptoms explain the relationships between sleep

  20. Cognitive function in patients with stable coronary heart disease: Related cerebrovascular and cardiovascular responses.

    Science.gov (United States)

    Gayda, Mathieu; Gremeaux, Vincent; Bherer, Louis; Juneau, Martin; Drigny, Joffrey; Dupuy, Olivier; Lapierre, Gabriel; Labelle, Véronique; Fortier, Annik; Nigam, Anil

    2017-01-01

    Chronic exercise has been shown to prevent or slow age-related decline in cognitive functions in otherwise healthy, asymptomatic individuals. We sought to assess cognitive function in a stable coronary heart disease (CHD) sample and its relationship to cerebral oxygenation-perfusion, cardiac hemodynamic responses, and [Formula: see text] peak compared to age-matched and young healthy control subjects. Twenty-two young healthy controls (YHC), 20 age-matched old healthy controls (OHC) and 25 patients with stable CHD were recruited. Cognitive function assessment included short term-working memory, perceptual abilities, processing speed, cognitive inhibition and flexibility and long-term verbal memory. Maximal cardiopulmonary function (gas exchange analysis), cardiac hemodynamic (impedance cardiography) and left frontal cerebral oxygenation-perfusion (near-infra red spectroscopy) were measured during and after a maximal incremental ergocycle test. Compared to OHC and CHD, YHC had higher [Formula: see text] peak, maximal cardiac index (CI max), cerebral oxygenation-perfusion (ΔO2 Hb, ΔtHb: exercise and recovery) and cognitive function (for all items) (Pcognitive inhibition and flexibility and long-term verbal memory (Pcognitive function (Pcognitive function (Pcognitive function, a similar cerebral oxygenation/perfusion during exercise but reduced one during recovery vs. their aged-matched healthy counterparts. In the all sample, cognitive functions correlated with [Formula: see text] peak, CI max and cerebral oxygenation-perfusion.

  1. Species A rotavirus NSP3 acquires its translation inhibitory function prior to stable dimer formation.

    Directory of Open Access Journals (Sweden)

    Hugo I Contreras-Treviño

    Full Text Available Species A rotavirus non-structural protein 3 (NSP3 is a translational regulator that inhibits or, under some conditions, enhances host cell translation. NSP3 binds to the translation initiation factor eIF4G1 and evicts poly-(A binding protein (PABP from eIF4G1, thus inhibiting translation of polyadenylated mRNAs, presumably by disrupting the effect of PABP bound to their 3'-ends. NSP3 has a long coiled-coil region involved in dimerization that includes a chaperone Hsp90-binding domain (HS90BD. We aimed to study the role in NSP3 dimerization of a segment of the coiled-coil region adjoining the HS90BD. We used a vaccinia virus system to express NSP3 with point mutations in conserved amino acids in the coiled-coil region and determined the effects of these mutations on translation by metabolic labeling of proteins as well as on accumulation of stable NSP3 dimers by non-dissociating Western blot, a method that separates stable NSP3 dimers from the monomer/dimerization intermediate forms of the protein. Four of five mutations reduced the total yield of NSP3 and the formation of stable dimers (W170A, K171E, R173E and R187E:K191E, whereas one mutation had the opposite effects (Y192A. Treatment with the proteasome inhibitor MG132 revealed that stable NSP3 dimers and monomers/dimerization intermediates are susceptible to proteasome degradation. Surprisingly, mutants severely impaired in the formation of stable dimers were still able to inhibit host cell translation, suggesting that NSP3 dimerization intermediates are functional. Our results demonstrate that rotavirus NSP3 acquires its function prior to stable dimer formation and remain as a proteasome target throughout dimerization.

  2. Oropharynx lesion biopsy

    Science.gov (United States)

    ... as papilloma) Fungal infections (such as candida) Histoplasmosis Oral lichen planus Precancerous sore (leukoplakia) Viral infections (such as Herpes simplex) Risks Risks of the procedure may ... Throat lesion biopsy; Biopsy - mouth or throat; Mouth lesion biopsy; Oral cancer - biopsy ...

  3. Cognitive function in patients with stable coronary heart disease: Related cerebrovascular and cardiovascular responses.

    Directory of Open Access Journals (Sweden)

    Mathieu Gayda

    Full Text Available Chronic exercise has been shown to prevent or slow age-related decline in cognitive functions in otherwise healthy, asymptomatic individuals. We sought to assess cognitive function in a stable coronary heart disease (CHD sample and its relationship to cerebral oxygenation-perfusion, cardiac hemodynamic responses, and [Formula: see text] peak compared to age-matched and young healthy control subjects. Twenty-two young healthy controls (YHC, 20 age-matched old healthy controls (OHC and 25 patients with stable CHD were recruited. Cognitive function assessment included short term-working memory, perceptual abilities, processing speed, cognitive inhibition and flexibility and long-term verbal memory. Maximal cardiopulmonary function (gas exchange analysis, cardiac hemodynamic (impedance cardiography and left frontal cerebral oxygenation-perfusion (near-infra red spectroscopy were measured during and after a maximal incremental ergocycle test. Compared to OHC and CHD, YHC had higher [Formula: see text] peak, maximal cardiac index (CI max, cerebral oxygenation-perfusion (ΔO2 Hb, ΔtHb: exercise and recovery and cognitive function (for all items (P<0.05. Compared to OHC, CHD patients had lower [Formula: see text] peak, CI max, cerebral oxygenation-perfusion (during recovery and short term-working memory, processing speed, cognitive inhibition and flexibility and long-term verbal memory (P<0.05. [Formula: see text] peak and CI max were related to exercise cerebral oxygenation-perfusion and cognitive function (P<0.005. Cerebral oxygenation-perfusion (exercise was related to cognitive function (P<0.005. Stable CHD patients have a worse cognitive function, a similar cerebral oxygenation/perfusion during exercise but reduced one during recovery vs. their aged-matched healthy counterparts. In the all sample, cognitive functions correlated with [Formula: see text] peak, CI max and cerebral oxygenation-perfusion.

  4. Endometrial aspiration biopsy: a non-invasive method of obtaining functional lymphoid progenitor cells and mature natural killer cells.

    LENUS (Irish Health Repository)

    McMenamin, Moya

    2012-09-01

    The aim of this study was to compare the efficacy of endometrial aspiration biopsy (EAB) with the more traditional dilatation and curettage (D&C) for the procurement of lymphoid progenitor cells and uterine natural killer (NK) populations in endometrial tissue. This prospective observational study conducted in a tertiary referral university hospital examined endometrium obtained from 32 women admitted for laparoscopic gynaecological procedures. Each participant had endometrium sampled using both EAB and D&C. Both methods were assessed as a source of uterine NK and lymphoid progenitor cells. Similar proportions of mature CD45+CD56+ NK cells (range 25.4-36.2%) and CD45+CD34+ lymphoid progenitors (range 1.2-2.0%) were found in tissue obtained using both EAB and D&C. These cells were adequate for flow cytometric analysis, magnetic bead separation and culture. Colony formation by the CD34+ population demonstrated maturational potential. Tissues obtained via endometrial biopsy and D&C are equivalent, by analysis of uterine NK and lymphoid progenitor cells. The aim of this study was to compare two methods of endometrial sampling - endometrial aspiration biopsy and traditional dilatation and curettage - for the procurement of haematopoietic stem cells and uterine natural killer (NK) populations in endometrial tissue. Thirty-two women who had gynaecological procedures in a tertiary referral hospital participated in this study and had endometrial tissue collected via both methods. Similar populations of mature NK cells and haematopoietic stem cells were found in tissue obtained using both endometrial aspiration biopsy and dilatation and curettage. Tissue obtained via endometrial aspiration biopsy was adequate for the culture and growth of haematopoietic stem cells. We conclude that tissue obtained via endometrial biopsy and dilatation and curettage is equivalent, by analysis of uterine NK and haematopoietic stem cells using flow cytometry. This has implications for further

  5. The influence of contrast media on kidney function in patients with stable coronary artery disease

    DEFF Research Database (Denmark)

    Reuter, Simon Bertram; Harutyunyan, Marina; Mygind, Naja Dam

    2014-01-01

    AIMS: To investigate the incidence of contrast media-induced nephropathy (CIN) in patients with stable coronary artery disease (CAD) referred for elective coronary intervention following hydration routines. The reversibility of CIN was followed in a 6 month-period. METHODS AND RESULTS: A total...... coronary interventions. Kidney function and the amount of contrast media used was not a predictor of CIN development. The induced CIN was not completely normalized in a 6-month follow-up period....

  6. Stereotactic breast biopsy with a biopsy gun

    International Nuclear Information System (INIS)

    Parker, S.H.; Lovin, J.; Luethke, J.; Jobe, W.E.; Hopper, K.D.; Yakes, W.F.

    1989-01-01

    With the recent introduction of stereotactic mammographic localizing devices, the authors have been performing histologic core needle breast biopsies in which the Bard biopsy gun is used in conjunction with sterotactic guidance. The authors have performed 60 breast gun biopsies with 16-gauge and 18-gauge biopsy-cut needles. These biopsies were followed immediately by traditional surgical excision. Pathologic results correlated well in 52 of the 60 patients, including 10 of 13 cancers. Three of the eight negative correlations occurred when diagnosis was made on gun biopsy but not on surgical biopsy. The stereotactic- guided gun biopsies appear to approach the surgical gold standard, decrease patient discomfort and potential disfigurement, lower the cost of breast biopsy, and lower the threshold necessary to perform breast biopsy

  7. Stable functionalization of germanium surface and its application in biomolecules immobilization

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Qi [State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, No.865, Changning Road, Shanghai 200050 (China); University of Chinese Academy of Sciences, No.19A, Yuquan Road, Beijing 100049 (China); Xu, Baojian [State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, No.865, Changning Road, Shanghai 200050 (China); Ye, Lin [Sate Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, No.865, Changning Road, Shanghai 200050 (China); University of Chinese Academy of Sciences, No.19A, Yuquan Road, Beijing 100049 (China); Tang, Teng; Huang, Shanluo; Du, Xiaowei [State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, No.865, Changning Road, Shanghai 200050 (China); University of Chinese Academy of Sciences, No.19A, Yuquan Road, Beijing 100049 (China); Bian, Xiaojun; Zhang, Jishen [State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, No.865, Changning Road, Shanghai 200050 (China); Di, Zengfeng, E-mail: zfdi@mail.sim.ac.cn [Sate Key Laboratory of Functional Materials for Informatics, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, No.865, Changning Road, Shanghai 200050 (China); Jin, Qinghui [State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, No.865, Changning Road, Shanghai 200050 (China); Zhao, Jianlong, E-mail: jlzhao@mail.sim.ac.cn [State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, No.865, Changning Road, Shanghai 200050 (China)

    2014-10-15

    Highlights: • An effective method to immobilize biomolecules on the functionalized Ge surface. • The surface of Ge was functionalized with 11-Mercaptoundecanoic acid (11-MUA). • Stable and uniform SAMs was obtained on Ge surface after 11-MUA treatment. • The functionalized Ge was employed as substrate for protein immobilization. • Paving the way of Ge for further applications in bioelectronics field. - Abstract: As a typical semiconductor material, germanium (Ge) has the potential to be utilized in microelectronics and bioelectronics. Herein, we present a simple and effective method to immobilize biomolecules on the surface of functionalized Ge. The surface oxide of Ge was removed with the pretreatment of hydrochloric acid and the Cl-terminated Ge reacted with 11-Mercaptoundecanoic acid (11-MUA). The surface of Ge was coated with 11-MUA self-assembled monolayers (SAMs) due to the bonding reaction between the sulfhydryl group of 11-MUA and Cl-terminated Ge. Furthermore, typical biomolecule, a green fluorescent protein was chosen to be immobilized on the surface of the functionalized Ge. Contact angle analysis, atomic force microscopy and X-ray photoelectron spectroscopy were used to study the characteristics including wettability, stability, roughness and component of the functionalized Ge, respectively. Fluorescence microscopy was utilized to indicate the efficiency of protein immobilization on the surface of the functionalized Ge. With these studies, stable and uniform functionalized monolayer was obtained on the surface of Ge after 11-MUA treatment and the functionalized Ge was effectively applied in protein immobilization. Furthermore, this study may pave the way for further applications such as the integration of bioelectronics and biosensors with the attractive semiconductor material-Ge in future work.

  8. Stable xenon CT measurement of cerebral blood flow in cardiac transplantation candidates: Correlation with cognitive function

    International Nuclear Information System (INIS)

    Bello, J.A.; Fink, M.E.; Hilal, S.K.; Rose, E.A.; Reemtsma, K.

    1987-01-01

    Thirteen consecutive unselected patients with NYHA class 4 cardiac failure referred for cardiac transplantation underwent neurologic examination and cerebral blood flow measurement (rCBF) using the stable xenon enhanced CT method on a GE9800 system. Eleven men and two women were studied (mean age = 43.8 +- 6.1). On neurological examination, six of the patients demonstrated normal mental function; the remaining seven patients demonstrated memory, language, or learning impairment. There was no difference in mean cardiac output between the groups (4.9 L/min +- 1.68 vs. 4.2L/min +- 1.57). rCBF was significantly reduced in the impaired group. Cognitive impairment in patients with cardiac failure can be correlated with cerebral ischemia. Stable xenon CT measurement of rCBF in transplant candidates may help identify patients requiring more rapid transplantation to prevent permanent cerebral injury

  9. Facile and green synthesis of highly stable L-cysteine functionalized copper nanoparticles

    International Nuclear Information System (INIS)

    Kumar, Nikhil; Upadhyay, Lata Sheo Bachan

    2016-01-01

    Highlights: • A facile and eco-friendly method for the synthesis of L-cysteine functionalized copper nanoparticles is reported. • Synthesis of Highly stable L-cysteine functionalized copper nanoparticles (∼40 nm) was done in an aqueous medium. • FTIR analysis shows that L-cysteine bound to the nanoparticle surface via thiol group. - Abstract: A simple eco-friendly method for L-cysteine capped copper nanoparticles (CCNPs) synthesis in aqueous solution has been developed. Glucose and L-cysteine were used as reducing agent and capping/functionalizing agent, respectively. Different parameters such as capping agent concentration, pH, reaction temperature, and reducing agent concentration were optimized during the synthesis. The L-cysteine capped copper nanoparticle were characterized by ultraviolet-visible spectroscopy, Fourier-transform infrared spectroscopy, X-ray diffraction, Particle size and zeta potential analyser, and high resolution transmission electron microscopy. Spherical shaped cysteine functionalized/capped copper nanoparticles with an average size of 40 nm were found to be highly stable at room temperature (RT) for a period of 1 month

  10. Facile and green synthesis of highly stable L-cysteine functionalized copper nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Nikhil, E-mail: nkumar.phd2011.bt@nitrr.ac.in; Upadhyay, Lata Sheo Bachan, E-mail: contactlataupadhyay@gmail.com

    2016-11-01

    Highlights: • A facile and eco-friendly method for the synthesis of L-cysteine functionalized copper nanoparticles is reported. • Synthesis of Highly stable L-cysteine functionalized copper nanoparticles (∼40 nm) was done in an aqueous medium. • FTIR analysis shows that L-cysteine bound to the nanoparticle surface via thiol group. - Abstract: A simple eco-friendly method for L-cysteine capped copper nanoparticles (CCNPs) synthesis in aqueous solution has been developed. Glucose and L-cysteine were used as reducing agent and capping/functionalizing agent, respectively. Different parameters such as capping agent concentration, pH, reaction temperature, and reducing agent concentration were optimized during the synthesis. The L-cysteine capped copper nanoparticle were characterized by ultraviolet-visible spectroscopy, Fourier-transform infrared spectroscopy, X-ray diffraction, Particle size and zeta potential analyser, and high resolution transmission electron microscopy. Spherical shaped cysteine functionalized/capped copper nanoparticles with an average size of 40 nm were found to be highly stable at room temperature (RT) for a period of 1 month.

  11. Stereotactic biopsy

    International Nuclear Information System (INIS)

    Mwangi, M.N.; Handa, A.

    2006-01-01

    This technology is capable of locating lesions precise detected by the mammography examinations. This devise allows the surgeon to position automatically the needle to perform the cytological/histological biopsy with maximum position accuracy. This is under sterile procedure. to position the lesion in the beam, two radiographic procedures are carried out: the first with the X-ray beam at an inclination of -15 degrees with respect to the position 0 degrees and the second at the inclination +15 degrees. After processing the film the lesion will appear on both radiographs but on light are of the negatoscope. With the cursor information is fed from four points. On the display the length of the needle will appear immediately. The length of the needle to be used in suction is chosen on the basis of the two values on the display. This information fed on the control panel will move the needle unit position where the lesion is. the needle is then introduced under local anaesthesia at the preselected length until it clicks into position. An exposure is made with needle in situ in position at +15 degrees and -15 degrees to ensure the needle is in position. the suction is then carried out and the needle removed. The machine is then reset to return at the initial position

  12. Open lung biopsy

    Science.gov (United States)

    Biopsy - open lung ... An open lung biopsy is done in the hospital using general anesthesia . This means you will be asleep and ... The open lung biopsy is done to evaluate lung problems seen on x-ray or CT scan .

  13. Bone lesion biopsy

    Science.gov (United States)

    Bone biopsy; Biopsy - bone ... the cut, then pushed and twisted into the bone. Once the sample is obtained, the needle is ... sample is sent to a lab for examination. Bone biopsy may also be done under general anesthesia ...

  14. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  15. The influence of contrast media on kidney function in patients with stable coronary artery disease.

    Science.gov (United States)

    Reuter, Simon Bertram; Harutyunyan, Marina; Mygind, Naja Dam; Jørgensen, Erik; Kastrup, Jens

    2014-08-01

    To investigate the incidence of contrast media-induced nephropathy (CIN) in patients with stable coronary artery disease (CAD) referred for elective coronary intervention following hydration routines. The reversibility of CIN was followed in a 6 month-period. A total of 447 patients referred for elective coronary intervention due to suspected CAD were included. Blood samples were collected before and 24 h after intervention and medical records were obtained. Patients had no drinking fluid restrictions and were routinely treated with a 1000 ml saline infusion. All patients were invited to a 6-month examination and collection of blood samples. A total of 19 patients (4.3%) developed CIN. CIN patients had a pre-investigation higher estimated glomerular filtration rate (eGRF), lower level of kidney failure and lower creatinine level than non-CIN patients. Kidney function was not normalized in CIN patients 6 months after the intervention. Two patients still met the definition of CIN. With no restriction in fluid intake and supplementary infusion of saline, only a few patients with stable CAD developed early indications of CIN during elective coronary interventions. Kidney function and the amount of contrast media used was not a predictor of CIN development. The induced CIN was not completely normalized in a 6-month follow-up period.

  16. Facile and green synthesis of highly stable L-cysteine functionalized copper nanoparticles

    Science.gov (United States)

    Kumar, Nikhil; Upadhyay, Lata Sheo Bachan

    2016-11-01

    A simple eco-friendly method for L-cysteine capped copper nanoparticles (CCNPs) synthesis in aqueous solution has been developed. Glucose and L-cysteine were used as reducing agent and capping/functionalizing agent, respectively. Different parameters such as capping agent concentration, pH, reaction temperature, and reducing agent concentration were optimized during the synthesis. The L-cysteine capped copper nanoparticle were characterized by ultraviolet-visible spectroscopy, Fourier-transform infrared spectroscopy, X-ray diffraction, Particle size and zeta potential analyser, and high resolution transmission electron microscopy. Spherical shaped cysteine functionalized/capped copper nanoparticles with an average size of 40 nm were found to be highly stable at room temperature (RT) for a period of 1 month

  17. Assessing the functional diversity of herbivorous reef fishes using a compound-specific stable isotope approach

    KAUST Repository

    Tietbohl, Matthew

    2016-12-01

    Herbivorous coral reef fishes play an important role in helping to structure their environment directly by consuming algae and indirectly by promoting coral health and growth. These fishes are generally separated into three broad groups: browsers, grazers, and excavators/scrapers, with these groupings often thought to have a fixed general function and all fishes within a group thought to have similar ecological roles. This categorization assumes a high level of functional redundancy within herbivorous fishes. However, recent evidence questions the use of this broad classification scheme, and posits that there may actually be more resource partitioning within these functional groupings. Here, I use a compound-specific stable isotope approach (CSIA) to show there appears to be a greater diversity of functional roles than previously assumed within broad functional groups. The δ13C signatures from essential amino acids of reef end-members (coral, macroalgae, detritus, and phytoplankton) and fish muscle were analyzed to investigate differences in resource use between fishes. Most end-members displayed clear isotopic differences, and most fishes within functional groups were dissimilar in their isotopic signature, implying differences in the resources they target. No grazers closely resembled each other isotopically, implying a much lower level of functional redundancy within this group; scraping parrotfish were also distinct from excavating parrotfish and to a lesser degree distinct between scrapers. This study highlights the potential of CSIA to help distinguish fine-scale ecological differences within other groups of reef organisms as well. These results question the utility of lumping nominally herbivorous fishes into broad groups with assumed similar roles. Given the apparent functional differences between nominally herbivorous reef fishes, it is important for managers to incorporate the diversity of functional roles these fish play.

  18. Assessing the functional diversity of herbivorous reef fishes using a compound-specific stable isotope approach

    KAUST Repository

    Tietbohl, Matthew

    2016-01-01

    Herbivorous coral reef fishes play an important role in helping to structure their environment directly by consuming algae and indirectly by promoting coral health and growth. These fishes are generally separated into three broad groups: browsers, grazers, and excavators/scrapers, with these groupings often thought to have a fixed general function and all fishes within a group thought to have similar ecological roles. This categorization assumes a high level of functional redundancy within herbivorous fishes. However, recent evidence questions the use of this broad classification scheme, and posits that there may actually be more resource partitioning within these functional groupings. Here, I use a compound-specific stable isotope approach (CSIA) to show there appears to be a greater diversity of functional roles than previously assumed within broad functional groups. The δ13C signatures from essential amino acids of reef end-members (coral, macroalgae, detritus, and phytoplankton) and fish muscle were analyzed to investigate differences in resource use between fishes. Most end-members displayed clear isotopic differences, and most fishes within functional groups were dissimilar in their isotopic signature, implying differences in the resources they target. No grazers closely resembled each other isotopically, implying a much lower level of functional redundancy within this group; scraping parrotfish were also distinct from excavating parrotfish and to a lesser degree distinct between scrapers. This study highlights the potential of CSIA to help distinguish fine-scale ecological differences within other groups of reef organisms as well. These results question the utility of lumping nominally herbivorous fishes into broad groups with assumed similar roles. Given the apparent functional differences between nominally herbivorous reef fishes, it is important for managers to incorporate the diversity of functional roles these fish play.

  19. Asymptotically Stable Solutions of a Generalized Fractional Quadratic Functional-Integral Equation of Erdélyi-Kober Type

    Directory of Open Access Journals (Sweden)

    Mohamed Abdalla Darwish

    2014-01-01

    Full Text Available We study a generalized fractional quadratic functional-integral equation of Erdélyi-Kober type in the Banach space BC(ℝ+. We show that this equation has at least one asymptotically stable solution.

  20. Smart biomaterials: Surfaces functionalized with proteolytically stable osteoblast-adhesive peptides

    Directory of Open Access Journals (Sweden)

    Annj Zamuner

    2017-09-01

    Full Text Available Engineered scaffolds for bone tissue regeneration are designed to promote cell adhesion, growth, proliferation and differentiation. Recently, covalent and selective functionalization of glass and titanium surfaces with an adhesive peptide (HVP mapped on [351–359] sequence of human Vitronectin allowed to selectively increase osteoblast attachment and adhesion strength in in vitro assays, and to promote osseointegration in in vivo studies. For the first time to our knowledge, in this study we investigated the resistance of adhesion sequences to proteolytic digestion: HVP was completely cleaved after 5 h. In order to overcome the enzymatic degradation of the native peptide under physiological conditions we synthetized three analogues of HVP sequence. A retro-inverted peptide D-2HVP, composed of D amino acids, was completely stable in serum-containing medium. In addition, glass surfaces functionalized with D-2HVP increased human osteoblast adhesion as compared to the native peptide and maintained deposition of calcium. Interestingly, D-2HVP increased expression of IBSP, VTN and SPP1 genes as compared to HVP functionalized surfaces. Total internal reflection fluorescence microscope analysis showed cells with numerous filopodia spread on D-2HVP-functionalized surfaces. Therefore, the D-2HVP sequence is proposed as new osteoblast adhesive peptide with increased bioactivity and high proteolytic resistance.

  1. Smart biomaterials: Surfaces functionalized with proteolytically stable osteoblast-adhesive peptides.

    Science.gov (United States)

    Zamuner, Annj; Brun, Paola; Scorzeto, Michele; Sica, Giuseppe; Castagliuolo, Ignazio; Dettin, Monica

    2017-09-01

    Engineered scaffolds for bone tissue regeneration are designed to promote cell adhesion, growth, proliferation and differentiation. Recently, covalent and selective functionalization of glass and titanium surfaces with an adhesive peptide (HVP) mapped on [351-359] sequence of human Vitronectin allowed to selectively increase osteoblast attachment and adhesion strength in in vitro assays, and to promote osseointegration in in vivo studies. For the first time to our knowledge, in this study we investigated the resistance of adhesion sequences to proteolytic digestion: HVP was completely cleaved after 5 h. In order to overcome the enzymatic degradation of the native peptide under physiological conditions we synthetized three analogues of HVP sequence. A retro-inverted peptide D-2HVP, composed of D amino acids, was completely stable in serum-containing medium. In addition, glass surfaces functionalized with D-2HVP increased human osteoblast adhesion as compared to the native peptide and maintained deposition of calcium. Interestingly, D-2HVP increased expression of IBSP, VTN and SPP1 genes as compared to HVP functionalized surfaces. Total internal reflection fluorescence microscope analysis showed cells with numerous filopodia spread on D-2HVP-functionalized surfaces. Therefore, the D-2HVP sequence is proposed as new osteoblast adhesive peptide with increased bioactivity and high proteolytic resistance.

  2. Stable evaluation of Green's functions in cylindrically stratified regions with uniaxial anisotropic layers

    Science.gov (United States)

    Moon, H.; Donderici, B.; Teixeira, F. L.

    2016-11-01

    We present a robust algorithm for the computation of electromagnetic fields radiated by point sources (Hertzian dipoles) in cylindrically stratified media where each layer may exhibit material properties (permittivity, permeability, and conductivity) with uniaxial anisotropy. Analytical expressions are obtained based on the spectral representation of the tensor Green's function based on cylindrical Bessel and Hankel eigenfunctions, and extended for layered uniaxial media. Due to the poor scaling of these eigenfunctions for extreme arguments and/or orders, direct numerical evaluation of such expressions can produce numerical instability, i.e., underflow, overflow, and/or round-off errors under finite precision arithmetic. To circumvent these problems, we develop a numerically stable formulation through suitable rescaling of various expressions involved in the computational chain, to yield a robust algorithm for all parameter ranges. Numerical results are presented to illustrate the robustness of the formulation including cases of practical interest.

  3. Stable evaluation of Green's functions in cylindrically stratified regions with uniaxial anisotropic layers

    Energy Technology Data Exchange (ETDEWEB)

    Moon, H., E-mail: haksu.moon@gmail.com [ElectroScience Laboratory, The Ohio State University, Columbus, OH 43212 (United States); Donderici, B., E-mail: burkay.donderici@halliburton.com [Sensor Physics & Technology, Halliburton Energy Services, Houston, TX 77032 (United States); Teixeira, F.L., E-mail: teixeira@ece.osu.edu [ElectroScience Laboratory, The Ohio State University, Columbus, OH 43212 (United States)

    2016-11-15

    We present a robust algorithm for the computation of electromagnetic fields radiated by point sources (Hertzian dipoles) in cylindrically stratified media where each layer may exhibit material properties (permittivity, permeability, and conductivity) with uniaxial anisotropy. Analytical expressions are obtained based on the spectral representation of the tensor Green's function based on cylindrical Bessel and Hankel eigenfunctions, and extended for layered uniaxial media. Due to the poor scaling of these eigenfunctions for extreme arguments and/or orders, direct numerical evaluation of such expressions can produce numerical instability, i.e., underflow, overflow, and/or round-off errors under finite precision arithmetic. To circumvent these problems, we develop a numerically stable formulation through suitable rescaling of various expressions involved in the computational chain, to yield a robust algorithm for all parameter ranges. Numerical results are presented to illustrate the robustness of the formulation including cases of practical interest.

  4. Functional and phenotypical comparison of myofibroblasts derived from biopsies and bronchoalveolar lavage in mild asthma and scleroderma

    Directory of Open Access Journals (Sweden)

    Hansson Lennart

    2006-01-01

    Full Text Available Abstract Background Activated fibroblasts, which have previously been obtained from bronchoalveolar lavage fluid (BALF, are proposed to be important cells in the fibrotic processes of asthma and scleroderma (SSc. We have studied the motility for BALF derived fibroblasts in patients with SSc that may explain the presence of these cells in the airway lumen. Furthermore, we have compared phenotypic alterations in activated fibroblasts from BALF and bronchial biopsies from patients with mild asthma and SSc that may account for the distinct fibrotic responses. Methods Fibroblasts were cultured from BALF and bronchial biopsies from patients with mild asthma and SSc. The motility was studied using a cell migration assay. Western Blotting was used to study the expression of alpha-smooth muscle actin (α-SMA, ED-A fibronectin, and serine arginine splicing factor 20 (SRp20. The protein expression pattern was analyzed to reveal potential biomarkers using two-dimensional electrophoresis (2-DE and sequencing dual matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-TOF. The Mann-Whitney method was used to calculate statistical significance. Results Increased migration and levels of ED-A fibronectin were observed in BALF fibroblasts from both groups of patients, supported by increased expression of RhoA, Rac1, and the splicing factor SRp20. However, these observations were exclusively accompanied by increased expression of α-SMA in patients with mild asthma. Compared to BALF fibroblasts in mild asthma, fibroblasts in SSc displayed a differential protein expression pattern of cytoskeletal- and scavenger proteins. These identified proteins facilitate cell migration, oxidative stress, and the excessive deposition of extracellular matrix observed in patients with SSc. Conclusion This study demonstrates a possible origin for fibroblasts in the airway lumen in patients with SSc and important differences between fibroblast

  5. MR-guided biopsies

    International Nuclear Information System (INIS)

    Gehl, H.B.; Frahm, C.

    1998-01-01

    Biopsies were the first 'intervention' under MR guidance. After initial difficulties concerning ferromagnetic biopsy instruments and the design of MR scanners, the latest technological improvements rendered MR guidance for biopsies more feasible. In this article we illustrate present-day clinical experience in the field of abdominal, breast and bone biopsy. Important aspects regarding the different designs of 'interventional' MR scanners and the visualization of instruments for biopsy are discussed. (orig.) [de

  6. DNA-based stable isotope probing: a link between community structure and function

    International Nuclear Information System (INIS)

    Uhlik, Ondrej; Jecna, Katerina; Leigh, Mary Beth; Mackova, Martina; Macek, Tomas

    2009-01-01

    DNA-based molecular techniques permit the comprehensive determination of microbial diversity but generally do not reveal the relationship between the identity and the function of microorganisms. The first direct molecular technique to enable the linkage of phylogeny with function is DNA-based stable isotope probing (DNA-SIP). Applying this method first helped describe the utilization of simple compounds, such as methane, methanol or glucose and has since been used to detect microbial communities active in the utilization of a wide variety of compounds, including various xenobiotics. The principle of the method lies in providing 13C-labeled substrate to a microbial community and subsequent analyses of the 13C-DNA isolated from the community. Isopycnic centrifugation permits separating 13C-labeled DNA of organisms that utilized the substrate from 12C-DNA of the inactive majority. As the whole metagenome of active populations is isolated, its follow-up analysis provides successful taxonomic identification as well as the potential for functional gene analyses. Because of its power, DNA-SIP has become one of the leading techniques of microbial ecology research. But from other point of view, it is a labor-intensive method that requires careful attention to detail during each experimental step in order to avoid misinterpretation of results.

  7. Hepatic encephalopathy in a liver transplant recipient with stable liver function.

    Science.gov (United States)

    Arab, Juan Pablo; Meneses, Luis; Pérez, Rosa M; Arrese, Marco; Benítez, Carlos

    2013-04-01

    Postshunt hepatic encephalopathy after liver transplantation (LT) is an infrequent condition and is commonly associated with portal occlusion or stenosis and the presence of a patent portosystemic shunt. Portal vein stenosis (PVS) or thrombosis (PVT) are uncommon complications after LT. The overall frequency of both complications is reported to be less than 3%. When PVS or PVT develop early after LT, the occlusion of the portal vein can have catastrophic consequences to the graft including acute liver failure and graft loss. Late PVT/PVS are asymptomatic in approximately 50% of the cases and mainly diagnosed by a routine ultrasound. Symptomatic postshunt hepatic encephalopathy (HE) is a very infrequent condition after LT that has been scarcely reported in the literature. We present here the case of a liver recipient with normal graft function who presented with hepatic encephalopathy 3 months after LT with stable liver function but a severe portal stenosis and the presence of a spontaneous portosystemic shunt whose successful endovascular treatment was followed by the complete resolution of the HE.

  8. Formation of stable and functional HIV-1 nucleoprotein complexes in vitro.

    Science.gov (United States)

    Tanchou, V; Gabus, C; Rogemond, V; Darlix, J L

    1995-10-06

    HIV genomic RNA resides within the nucleocapsid, in the interior of the virus, which serves to protect the RNA against nuclease degradation and to promote its reverse transcription. To investigate the role of nucleocapsid protein (NCp7) in the stability and replication of genomic RNA within the nucleocapsid, we used NCp7, reverse transcriptase (RT) and RNAs representing the 5' and 3' regions of the genome to reconstitute functional HIV-1 nucleocapsids. The nucleoprotein complexes generated in vitro were found to be stable, which, according to biochemical and genetic data, probably results from the tight binding of NCp7 molecules to the RNA and strong NCp7/NCp7 interactions. The nucleoprotein complexes efficiently protected viral RNA against RNase degradation and, at the same time, promoted viral DNA synthesis by RT. DNA strand transfer from the 5' to the 3' RNA template was very efficient in nucleoprotein complexes formed in the presence of both RNAs, but not when the RNAs were in separate complexes. These results indicate that the in vitro reconstituted HIV-1 nucleoprotein complexes function like virion nucleocapsids and thus provide a way to study at the molecular level this viral substructure and the synthesis of proviral DNA, and to search for new anti-HIV agents.

  9. Induction of UV-resistant DNA replication in Escherichia coli: Induced stable DNA replication as an SOS function

    International Nuclear Information System (INIS)

    Kogoma, T.; Torrey, T.A.; Connaughton, M.J.

    1979-01-01

    The striking similarity between the treatments that induce SOS functions and those that result in stable DNA replication (continuous DNA replication in the absence of protein synthesis) prompted us to examine the possibility of stable DNA replication being a recA + lexA + -dependent SOS function. In addition to the treatments previously reported, ultraviolet (UV) irradiation or treatment with mitomycin C was also found to induce stable DNA replication. The thermal treatment of tif-1 strains did not result in detectable levels of stable DNA replication, but nalidixic acid readily induced the activity in these strains. The induction of stable DNA replication with nalidixic acid was severely suppressed in tif-1 lex A mutant strains. The inhibitory activity of lexA3 was negated by the presence of the spr-5l mutation, an intragenic suppressor of lexA3. Induced stable DNA replication was found to be considerably more resistant to UV irradiation than normal replication both in a uvr A6 strain and a uvr + strain. The UV-resistant replication occurred mostly in the semiconservative manner. The possible roles of stable DNA replication in repair of damaged DNA are discussed. (orig.)

  10. Salivary gland biopsy

    Science.gov (United States)

    ... also be performed to diagnose diseases such as Sjogren syndrome . How to Prepare for the Test There is ... few days after the biopsy. The biopsy for Sjogren syndrome requires an injection of the anesthetic in the ...

  11. Noncovalently functionalized graphitic mesoporous carbon as a stable support of Pt nanoparticles for oxygen reduction

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Yuyan; Zhang, Sheng; Kou, Rong; Wang, Chongmin; Viswanathan, Vilayanur; Liu, Jun; Wang, Yong; Lin, Yuehe [Pacific Northwest National Laboratory, Richland, WA 99352 (United States); Wang, Xiqing; Dai, Sheng [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States)

    2010-04-02

    We report a durable electrocatalyst support, highly graphitized mesoporous carbon (GMPC), for oxygen reduction in polymer electrolyte membrane (PEM) fuel cells. GMPC is prepared through graphitizing the self-assembled soft-template mesoporous carbon (MPC) under high temperature. Heat-treatment at 2800 C greatly improves the degree of graphitization while most of the mesoporous structures and the specific surface area of MPC are retained. GMPC is then noncovalently functionalized with poly(diallyldimethylammonium chloride) (PDDA) and loaded with Pt nanoparticles by reducing Pt precursor (H{sub 2}PtCl{sub 6}) in ethylene glycol. Pt nanoparticles of {proportional_to}3.0 nm in diameter are uniformly dispersed on GMPC. Compared to Pt supported on Vulcan XC-72 carbon black (Pt/XC-72), Pt/GMPC exhibits a higher mass activity towards oxygen reduction reaction (ORR) and the mass activity retention (in percentage) is improved by a factor of {proportional_to}2 after 44 h accelerated degradation test under the potential step (1.4-0.85 V) electrochemical stressing condition which focuses on support corrosion. The enhanced activity and durability of Pt/GMPC are attributed to the graphitic structure of GMPC which is more resistant to corrosion. These findings demonstrate that GMPC is a promising oxygen reduction electrocatalyst support for PEM fuel cells. The approach reported in this work provides a facile, eco-friendly promising strategy for synthesizing stable metal nanoparticles on hydrophobic support materials. (author)

  12. Predictive factors for functional outcome and failure in angular stable osteosynthesis of the proximal humerus.

    LENUS (Irish Health Repository)

    Hardeman, Francois

    2012-02-01

    Angular stable osteosynthesis has become the gold standard in the operative treatment of proximal humeral fractures. The aim of this article is to determine the indications for osteosynthesis versus primary arthroplasty based on clinical and radiological parameters.

  13. Highly Stable, Functional Hairy Nanoparticles and Biopolymers from Wood Fibers: Towards Sustainable Nanotechnology.

    Science.gov (United States)

    Sheikhi, Amir; Yang, Han; Alam, Md Nur; van de Ven, Theo G M

    2016-07-20

    Nanoparticles, as one of the key materials in nanotechnology and nanomedicine, have gained significant importance during the past decade. While metal-based nanoparticles are associated with synthetic and environmental hassles, cellulose introduces a green, sustainable alternative for nanoparticle synthesis. Here, we present the chemical synthesis and separation procedures to produce new classes of hairy nanoparticles (bearing both amorphous and crystalline regions) and biopolymers based on wood fibers. Through periodate oxidation of soft wood pulp, the glucose ring of cellulose is opened at the C2-C3 bond to form 2,3-dialdehyde groups. Further heating of the partially oxidized fibers (e.g., T = 80 °C) results in three products, namely fibrous oxidized cellulose, sterically stabilized nanocrystalline cellulose (SNCC), and dissolved dialdehyde modified cellulose (DAMC), which are well separated by intermittent centrifugation and co-solvent addition. The partially oxidized fibers (without heating) were used as a highly reactive intermediate to react with chlorite for converting almost all aldehyde to carboxyl groups. Co-solvent precipitation and centrifugation resulted in electrosterically stabilized nanocrystalline cellulose (ENCC) and dicarboxylated cellulose (DCC). The aldehyde content of SNCC and consequently surface charge of ENCC (carboxyl content) were precisely controlled by controlling the periodate oxidation reaction time, resulting in highly stable nanoparticles bearing more than 7 mmol functional groups per gram of nanoparticles (e.g., as compared to conventional NCC bearing AFM), transmission electron microscopy (TEM), and scanning electron microscopy (SEM) attested to the rod-like morphology. Conductometric titration, Fourier transform infrared spectroscopy (FTIR), nuclear magnetic resonance (NMR), dynamic light scattering (DLS), electrokinetic-sonic-amplitude (ESA) and acoustic attenuation spectroscopy shed light on the superior properties of these

  14. Neurocognitive function in clinically stable individuals with long-term bipolar I disorder: Comparisons with schizophrenia patients and controls

    Directory of Open Access Journals (Sweden)

    Pei-Yun Lin

    2017-05-01

    Full Text Available This study compared the levels of the five domains of neurocognitive function—executive function, attention, memory, verbal comprehension, and perceptual organization—among clinically stable individuals with long-term bipolar I disorder, individuals with long-term schizophrenia, and a group of controls. We recruited a total of 93 clinically stable individuals with bipolar I disorder, 94 individuals with schizophrenia, and 106 controls in this study. Their neurocognitive function was measured using a series of neurocognitive function tests: the Wechsler Adult Intelligence Scale—Third Edition (WAIS-III, Line Cancellation Test, Visual Form Discrimination, Controlled Oral Word Association Test, Wisconsin Card Sorting Test, Continuous Performance Task, and Wechsler Memory Scale—Third Edition. Neurocognitive function was compared among the three groups through a multivariate analysis of variance. The results indicated that when the effect of age was controlled, clinically stable individuals with bipolar I disorder and those with schizophrenia demonstrated poor neurocognitive function on all tests except for the WAIS-III Similarity and Information and the Line Cancellation Test. The individuals with bipolar I disorder had similar levels of neurocognitive function compared with the schizophrenia group, but higher levels of neurocognitive function on the WAIS-III Comprehension, Controlled Oral Word Association Test, and Wechsler Memory Scale—Third Edition Auditory Immediate and Delayed Index and Visual Immediate and Delayed Index. The conclusions of this study suggest that compared with controls, individuals with long-term bipolar I disorder and those with long-term schizophrenia have poorer neurocognitive function, even when clinically stable. Individuals with long-term bipolar I disorder and those with long-term schizophrenia have similar levels of deficits in several domains of neurocognitive function.

  15. Abdominal wall fat pad biopsy

    Science.gov (United States)

    Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... is the most common method of taking an abdominal wall fat pad biopsy . The health care provider cleans the ...

  16. Functional Marker Assisted Improvement of Stable Cytoplasmic Male Sterile Lines of Rice for Bacterial Blight Resistance

    Directory of Open Access Journals (Sweden)

    Jegadeesan Ramalingam

    2017-06-01

    Full Text Available Bacterial blight (BB, caused by Xanthomonas oryzae pv.oryzae is one among the major diseases in rice, which in severe condition cause losses up to 60% in total yield. Marker assisted pyramiding of three broad spectrum BB resistance genes (xa5, xa13, and Xa21 in prominent rice varieties is the most economical and effective strategy for the management of the BB disease. We report here the pyramiding of three genes (xa5, xa13, and Xa21 in maintainer lines (CO 2B, CO 23B, and CO 24B of three promising wild abortive cytoplasmic male sterile lines (CO 2A, CO 23A, and CO 24A through functional markers assisted back cross breeding. IRBB60 with xa5, xa13, and Xa21 genes is used as a donor parent. BC2F1 and BC2F2 generations from a cross of CO 2B, CO 23B, and CO 24B with IRBB60 were evaluated for bacterial blight and non-fertility restoration. In BC2F1, plants with all three resistance genes (xa5, xa13, and Xa21 and high parent genome recovery was identified. In BC2F2, plants with all resistance genes and without fertility restorer (Rf3 and Rf4 were selected. Based on agronomic traits, BB resistance and maintenance of sterility, two plants each in CO 2B × IRBB60, CO 24B × IRBB60 and one plant in CO 23B × IRBB60 combinations were identified. The identified lines were crossed with respective male sterile lines for conversion of improved B line into CMS line through back-crossing, in addition to selfing. The plants with high recurrent genome and phenotypically similar to parental lines and sterile are being used for the hybrid rice development program. Currently, using these lines (improved CMS line, test crosses were made to develop new rice hybrids. Hybrids combinations viz., CO 23A × AD08009R and CO 24A × IET20898R were found to be stable at different locations with high yield. The R line used in this study has been introgressed with xa5, xa13, and Xa21 genes in a separate breeding program. These new hybrids with resistance against bacterial blight

  17. Cognitive Performance associated to functional outcomes in stable outpatients with schizophrenia

    Directory of Open Access Journals (Sweden)

    Silvia Zaragoza Domingo, MA

    2015-09-01

    Conclusion: Most prevalent impairments were on executive function and processing speed domains; however, working memory showed the strongest relationship to functional disability. Monitoring cognitive function during follow up is critical to understand patient’s everyday functional capacity.

  18. Biomimetic triblock copolymer membrane arrays: a stable template for functional membrane proteins

    DEFF Research Database (Denmark)

    Gonzalez-Perez, A.; Jensen, Karin Bagger Stibius; Vissing, Thomas

    2009-01-01

    It is demonstrated that biomimetic stable triblock copolymer membrane arrays can be prepared using a scaffold containing 64 apertures of 300 μm diameter each. The membranes were made from a stock solution of block copolymers with decane as a solvent using a new deposition method. By using decane...

  19. DNA-based stable isotope probing: a link between community structure and function

    Czech Academy of Sciences Publication Activity Database

    Uhlík, Ondřej; Ječná, K.; Leigh, M. B.; Macková, Martina; Macek, Tomáš

    2009-01-01

    Roč. 407, č. 12 (2009), s. 3611-3619 ISSN 0048-9697 Grant - others:GA MŠk(CZ) 2B08031 Program:2B Institutional research plan: CEZ:AV0Z40550506 Keywords : DNA-based stable isotope probing * microbial diversity * bioremediation Subject RIV: EI - Biotechnology ; Bionics Impact factor: 2.905, year: 2009

  20. La biopsie prostatique

    OpenAIRE

    DJEDOUI, MERIEM

    2013-01-01

    La preuve d'un cancer de la prostate est apportée par la biopsie prostatique. Malheureusement, une biopsie négative, bien que rassurante, ne suffit pas à exclure un noyau cancéreux à côté duquel l'aiguille est passée. L'urologue peut être amené à proposer une nouvelle biopsie, en augmentant, s'il le faut, le nombre de prélèvements de tissu prostatique. Ayant connu Le but d'une biopsie prostatique, le patient pourrait maintenant décider d'entrer dans d'autres alternatives qui...

  1. Biopsy-proven childhood glomerulonephritis in Johor.

    Science.gov (United States)

    Khoo, J J; Pee, S; Thevarajah, B; Yap, Y C; Chin, C K

    2004-06-01

    There has been no published study of biopsy-proven childhood glomerulonephritis in Malaysia. To determine the pattern of childhood glomerulonephritis in Johor, Malaysia from a histopathological perspective and the various indications used for renal biopsy in children. Retrospective study was done of all renal biopsies from children under 16 years of age, received in Sultanah Aminah Hospital, Johor between 1994 and 2001. The histopathological findings were reviewed to determine the pattern of biopsy-proven glomerulonephritis. The indications for biopsy, mode of therapy given after biopsy and the clinical outcome were studied. 122 adequate biopsies were received, 9 children had repeat biopsies. Of the 113 biopsies, minimal change disease formed the most common histopathological diagnosis (40.7%) while lupus nephritis formed the most common secondary glomerulonephritis (23.0%). The main indications for biopsy were nephrotic syndrome (50.8%), lupus nephritis (25.4%) and renal impairment (13.1%). The mode of therapy was changed in 59.8% of the children. Of 106 patients followed-up, 84 children were found to have normal renal function in remission or on treatment. 4 patients developed chronic renal impairment and 16 reached end stage renal disease. Five of the 16 children with end stage disease had since died while 11 were on renal replacement therapy. Another 2 patients died of other complications. The pattern of childhood GN in our study tended to reflect the more severe renal parenchymal diseases in children and those requiring more aggressive treatment. This was because of our criteria of selection (indication) for renal biopsy. Renal biopsy where performed appropriately in selected children may not only be a useful investigative tool for histological diagnosis and prognosis but may help clinicians plan the optimal therapy for these children.

  2. Aortography following subdiaphragmal aortic biopsy

    International Nuclear Information System (INIS)

    Schimmler, J.

    1982-01-01

    A juxtaposition of the subdiaphragmal and infrarenal translumbar aortic biopsy sites showed decisive advantages in favour of the higher site: a more stable position because of better anatomic fixation and rarer incidence of vascular alterations, a wider vascular lumen. Disadvantages lie in the fact that the large visceral arteries (especially Tr. coeliacus) branch off nearly and in the close anatomic relationship to large abdominal organs and the thoracal region. Evaluation of the radiographical image of the vascular tree after subdiaphragmal aortic biopsy showed an average 82% of the vessels to the area of the Knees to be assessable (renal arteries approximately 93%, popliteal arteries approximately 70%). Beyong, the method proved unsatisfactory: 52% of the vessels could not, or not safety, be evaluated. A relatively broad spectrum of indications by comparison with transfemoral catheter aortography had no influence on the rate of complications with reference to either method. A comparison of the topographic conditions shows the need for even more scrupulons observation of the technique in subdiaphragmal biopsy than in the infrarenal one. To sum up the results obtained, subdiaphregmal translumbar aortography is to be preferred to the infrarenal one where transfemoral catheter aortography is contra-indicated, within the limits mentioned. (orig.) [de

  3. Biopsy - Multiple Languages

    Science.gov (United States)

    ... Biopsy - العربية (Arabic) Bilingual PDF Health Information Translations Breast Biopsy - العربية (Arabic) Bilingual PDF Health Information Translations Colposcopy - العربية (Arabic) Bilingual PDF ...

  4. A time-frequency analysis method to obtain stable estimates of magnetotelluric response function based on Hilbert-Huang transform

    Science.gov (United States)

    Cai, Jianhua

    2017-05-01

    The time-frequency analysis method represents signal as a function of time and frequency, and it is considered a powerful tool for handling arbitrary non-stationary time series by using instantaneous frequency and instantaneous amplitude. It also provides a possible alternative to the analysis of the non-stationary magnetotelluric (MT) signal. Based on the Hilbert-Huang transform (HHT), a time-frequency analysis method is proposed to obtain stable estimates of the magnetotelluric response function. In contrast to conventional methods, the response function estimation is performed in the time-frequency domain using instantaneous spectra rather than in the frequency domain, which allows for imaging the response parameter content as a function of time and frequency. The theory of the method is presented and the mathematical model and calculation procedure, which are used to estimate response function based on HHT time-frequency spectrum, are discussed. To evaluate the results, response function estimates are compared with estimates from a standard MT data processing method based on the Fourier transform. All results show that apparent resistivities and phases, which are calculated from the HHT time-frequency method, are generally more stable and reliable than those determined from the simple Fourier analysis. The proposed method overcomes the drawbacks of the traditional Fourier methods, and the resulting parameter minimises the estimation bias caused by the non-stationary characteristics of the MT data.

  5. Tools for functional analysis of faults and methods of fault-stable motion control

    International Nuclear Information System (INIS)

    Timofeev, A.V.

    2003-01-01

    In this article a big attention is given to the problems of functional diagnostics, when control and faults diagnostics are made in real time simultaneously in the process of functioning of controlled dynamical systems

  6. Improved transvenous liver biopsy needle

    DEFF Research Database (Denmark)

    Henriksen, Jens Henrik Sahl; Matzen, P; Christoffersen, P

    1979-01-01

    A modified type of the standard transvenous cholangiography biopsy needle is described. The modified tranvenous liver biopsy needle caused only minimal artefactual changes of the liver biopsy specimens. The new type of biopsy needle is a modified Menghini needle. The conventional Menghini needle...... should be avoided for transvenous catheter biopsies because of risk of leaving catheter fragments in the liver....

  7. Angular stable plates in proximal meta-epiphyseal tibial fractures: study of joint restoration and clinical and functional evaluation.

    Science.gov (United States)

    Giannotti, S; Giovannelli, D; Dell'Osso, G; Bottai, V; Bugelli, G; Celli, F; Citarelli, C; Guido, G

    2016-04-01

    The tibial plateau fractures involve one of the main weight bearing joints of the human body. The goals of surgical treatment are anatomical reduction, articular surface reconstruction and high primary stability. The aim of this study was to evaluate the clinical and functional outcomes after internal plate fixation of this kind of fractures. From January 2009 to December 2012, we treated 75 cases of tibial plateau fracture with angular stable plates. We used Rasmussen Score and the Knee Society Score for the clinical and functional evaluation. Twenty-five cases that underwent hardware removal had arthroscopic and CT evaluation of the joint. No complications occurred. The clinical and functional evaluation, performed by the KSS and Rasmussen Score, highlighted the high percentage of good-to-excellent results (over 90 %). In every case, the range of motion was good with flexion >90°. Arthroscopy showed the presence of chondral damage in 100 % of patients. In all the cases, we found that X-ray images seem better than the CT images. Angular stable plates allow to obtain a good primary stability, permitting an early joint recovery with an excellent range of motion. Avoiding to perform a knee arthrotomy at the time of fracture reduction could prove to be an advantage in terms of functional recovery. The meniscus on the injured bone should be preserved in order to maintain good function of the joint. X-ray images remain the gold standard in checking the progression of post-traumatic osteoarthritis.

  8. Stable isotope probing to study functional components of complex microbial ecosystems.

    Science.gov (United States)

    Mazard, Sophie; Schäfer, Hendrik

    2014-01-01

    This protocol presents a method of dissecting the DNA or RNA of key organisms involved in a specific biochemical process within a complex ecosystem. Stable isotope probing (SIP) allows the labelling and separation of nucleic acids from community members that are involved in important biochemical transformations, yet are often not the most numerically abundant members of a community. This pure culture-independent technique circumvents limitations of traditional microbial isolation techniques or data mining from large-scale whole-community metagenomic studies to tease out the identities and genomic repertoires of microorganisms participating in biological nutrient cycles. SIP experiments can be applied to virtually any ecosystem and biochemical pathway under investigation provided a suitable stable isotope substrate is available. This versatile methodology allows a wide range of analyses to be performed, from fatty-acid analyses, community structure and ecology studies, and targeted metagenomics involving nucleic acid sequencing. SIP experiments provide an effective alternative to large-scale whole-community metagenomic studies by specifically targeting the organisms or biochemical transformations of interest, thereby reducing the sequencing effort and time-consuming bioinformatics analyses of large datasets.

  9. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    The aim of the study was to compare three sampling techniques used in routine diagnostics to identify the microbiota in chronic venous leg ulcers. A total of 46 patients with persisting venous leg ulcers were included in the study. At inclusion, swab, biopsy and filter paper pad samples were...... collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... species present in chronic wounds, thus avoiding complications during and after biopsy sampling....

  10. Use of stable helium tracer for the early detection of impaired pulmonary function

    International Nuclear Information System (INIS)

    Susskind, H.; Richards, P.; Atkins, H.L.

    1975-01-01

    Methodology and instrumentation are being developed to measure distal airway closure, a very sensitive diagnostic technique for the early detection of emphysema and other obstructive lung diseases and premature closure indicating abnormalities. The procedure is rapid and involves the inhalation of only a 1 ml bolus of readily available stable 4 He, continuous measurement of its concentration in the exhaled air with a helium leak detector type of mass spectrometer, and the subsequent analysis of the single-breath washout curve. Helium appears to be an ideal tracer, well-suited for testing in clinics and hospitals, as well as for epidemiological studies relating the effects of atmospheric pollutants and lung impairment and for screening of large populations for pulmonary dysfunction

  11. Phosphorylcholine functionalized dendrimers for the formation of highly stable and reactive gold nanoparticles and their glucose conjugation for biosensing

    International Nuclear Information System (INIS)

    Jia Lan; Lv Liping; Xu Jianping; Ji Jian

    2011-01-01

    Phosphorylcholine (PC)-functionalized poly(amido amine) (PAMAM) dendrimers were prepared and used as both reducing and stabilizing agents for synthesis of highly stable and reactive gold nanoparticles (Au NPs). Biomimetic PC-functionalized PAMAM dendrimers-stabilized gold nanoparticles (Au DSNPs) were formed by simply mixing the PC modified amine-terminated fifth-generation PAMAM dendrimers (G5-PC) with AuCl 4 − ions by controlling the pH, no additional reducing agents or other stabilizers were needed. The obtained Au DSNPs were shown to be spherical, with particle diameters ranging from 5 to 12 nm, the sizes and growth kinetics of Au DSNPs could be tuned by changing the pH and the initial molar ratio of dendrimers to gold as indicated by transmission electron microscopy (TEM) and UV–Vis data. The prepared Au DSNPs showed excellent stability including: (1) stable at wide pH (7–13) values; (2) stable at high salt concentrations up to 2 M NaCl; (3) non-specific protein adsorption resistance. More importantly, surface functionalization could be performed by introducing desired functional groups onto the remained reactive amine groups. This was exemplified by the glucose conjugation. The glucose conjugated Au DSNPs showed bio-specific interaction with Concanavalin A (Con A), which induced aggregation of the Au NPs. Colorimetric detection of Con A based on the plasmon resonance of the glucose conjugated Au DSNPs was realized. A limit of detection (LOD) for Con A was 0.6 μM, based on a signal-to-noise ratio (S/N) of 3. These findings demonstrated that the PC modified Au DSNPs could potentially serve as a versatile nano-platform for the biomedical applications.

  12. Generating functional of the mean field in quantum electrodynamics with non-stable vacuum

    International Nuclear Information System (INIS)

    Gitman, D.M.; Kuchin, V.A.

    1981-01-01

    Generating functional for calculating a mean field, in the case of unstable vacuum, in quantum field theory has been suggested. Continual representation for the generating functional of the mean field has been found in the case of quantum electrodynamics with an external field. Generating electron-positron pairs from vacuum [ru

  13. Breast biopsy -- stereotactic

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/stereo-breast.pdf . Updated 2016. Accessed March 14, 2017. Parker C, Umphrey H, Bland K. The role of stereotactic breast biopsy in the management of breast disease. In: Cameron ...

  14. Breast biopsy -- ultrasound

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/us-guidedbreast.pdf . Updated 2016. Accessed March 14, 2017. Torrente J, Brem RF. Minimally invasive image-guided breast biopsy and ablation. In: Mauro MA, Murphy KPJ, Thomson ...

  15. Pleural needle biopsy

    Science.gov (United States)

    ... own. Sometimes, a chest tube is needed to drain the air and expand the lung. There is also a chance of excessive blood loss. Considerations If a closed pleural biopsy is not enough to make a diagnosis, ...

  16. Colposcopy - directed biopsy

    Science.gov (United States)

    ... squamous cells - colposcopy; Pap smear - colposcopy; HPV - colposcopy; Human papilloma virus - colposcopy; Cervix - colposcopy; Colposcopy ... also called cervical dysplasia) Cervical warts (infection with human papilloma virus , or HPV) If the biopsy does not ...

  17. Liver biopsy under hypnosis.

    Science.gov (United States)

    Adams, P C; Stenn, P G

    1992-09-01

    Two patients underwent outpatient percutaneous liver biopsy under hypnosis without complications. One patient had severe anxiety about the procedure because of a previous adverse experience with liver biopsy and the other had a history of severe allergy to local anesthesia. Both patients had undergone a session of hypnosis at least once prior to the biopsy. One received no local anesthetic and the other received 1% lidocaine as a local anesthetic. Both patients were completely cooperative during the procedure with the required respiratory maneuvers. Both patients stated that they were aware of the procedure under hypnosis but described no pain and would be most willing to have the procedure done under hypnosis in the future. Hypnosis can be a useful method of preparing carefully selected patients for percutaneous liver biopsy.

  18. Significant association between renal function and area of amyloid deposition in kidney biopsy specimens in both AA amyloidosis associated with rheumatoid arthritis and AL amyloidosis.

    Science.gov (United States)

    Kuroda, Takeshi; Tanabe, Naohito; Hasegawa, Eriko; Wakamatsu, Ayako; Nozawa, Yukiko; Sato, Hiroe; Nakatsue, Takeshi; Wada, Yoko; Ito, Yumi; Imai, Naofumi; Ueno, Mitsuhiro; Nakano, Masaaki; Narita, Ichiei

    2017-06-01

    The kidney is a major target organ for systemic amyloidosis, which results in proteinuria and an elevated serum creatinine level. The clinical manifestations and precursor proteins of amyloid A (AA) and light-chain (AL) amyloidosis are different, and the renal damage due to amyloid deposition also seems to differ. The purpose of this study was to clarify haw the difference in clinical features between AA and AL amyloidosis are explained by the difference in the amount and distribution of amyloid deposition in the renal tissues. A total of 119 patients participated: 58 patients with an established diagnosis of AA amyloidosis (AA group) and 61 with AL amyloidosis (AL group). We retrospectively investigated the correlation between clinical data, pathological manifestations, and the area occupied by amyloid in renal biopsy specimens. In most of the renal specimens the percentage area occupied by amyloid was less than 10%. For statistical analyses, the percentage area of amyloid deposition was transformed to a common logarithmic value (Log 10 %amyloid). The results of sex-, age-, and Log 10 %amyloid-adjusted analyses showed that systolic blood pressure (SBP) was higher in the AA group. In terms of renal function parameters, serum creatinine, creatinine clearance (Ccr) and estimated glomerular filtration rate (eGFR) indicated significant renal impairment in the AA group, whereas urinary protein indicated significant renal impairment in the AL group. Pathological examinations revealed amyloid was predominantly deposited at glomerular basement membrane (GBM) and easily transferred to the mesangial area in the AA group, and it was predominantly deposited at in the AL group. The degree of amyloid deposition in the glomerular capillary was significantly more severe in AL group. The frequency of amyloid deposits in extraglomerular mesangium was not significantly different between the two groups, but in AA group, the degree amyloid deposition was significantly more severe, and

  19. Corpus vitreum, retina og chorioidea biopsi

    DEFF Research Database (Denmark)

    Scherfig, Erik Christian Høegh

    2002-01-01

    oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma......oftalmology, biopsy, choroid, corpus vitreum, retina, malignant melanoma, biopsy technic, retinoblastoma...

  20. Biopsy in Musculoskeletal Tumors

    Directory of Open Access Journals (Sweden)

    Mohammad Gharehdaghi

    2014-09-01

    Full Text Available Diagnosis of bone tumors is based on careful evaluation of clinical, imaging and a pathologic findings. So the biopsy of bone and soft tissue sarcomas is the final step in evaluation and a fundamental step in the diagnosis of the lesion. It should not be performed as a shortcut to diagnosis (1. The biopsy should be performed in order to confirm the diagnosis and differentiate among few diagnoses after careful staged studies. Real and artificial changes in imaging studies will be superimposed after performing biopsy, which may alter the interpretation if done after biopsy is taken (1. The correct management of a sarcoma depends on the accurate diagnosis. Inadequate, inapprppriate, or inaccurate non-representative biopsy leads to poorer outcome in terms of survivorship and limb salvage. An incorrect, unplanned incision and biopsy may unnecessarily contaminate uninvolved compartments which may convert a salvageable limb to amputation. Anatomic approach along with the proper biopsy techniques may lead to success or catastrophe. It is clear that in patients with inappropriate biopsy, the chance of the need to change the treatment to more radical than would originally be expected is significantly higher. Also it is more probable to need to  convert curative to palliative treatment and to require adjuvant radiotherapy in patients with inappropriate biopsies. Patients with sarcoma are best served by early referral to a specialized center where staged investigations and biopsy can be performed with minimal morbidity (3. Open biopsy is still considered the gold standard; however, recent studies suggest comparable results with percutaneous core needle biopsy. Our study on 103 consecutive CNB and open biopsy showed comparable results as well. Surgeons need to answer to two questions prior to performing a biopsy: 1-          Where is the best part of the lesion to be biopsied? 2-          What is the safest route without contaminating

  1. Discrete Green's Theorem, Green's Functions and Stable Radiative FDTD Boundary Conditions

    NARCIS (Netherlands)

    Arnold, J.M.; Hon, de B.P.

    2007-01-01

    We propose a radiative boundary condition for the discrete-grid formulation of Helmholtz’ equation, based on rational approximation in the frequency domain of a Green’s function for the discretised system. This boundary condition is free from instabilities.

  2. Stable MCC binding to the APC/C is required for a functional spindle assembly checkpoint

    DEFF Research Database (Denmark)

    Hein, Jamin B; Nilsson, Jakob

    2014-01-01

    stably to the APC/C. Whether MCC formation per se is sufficient for a functional SAC or MCC association with the APC/C is required remains unclear. Here, we analyze the role of two conserved motifs in Cdc20, IR and C-Box, in binding of the MCC to the APC/C. Mutants in both motifs assemble the MCC....../C is critical for a functional SAC....

  3. Synthesis, characterization, and in vitro biological evaluation of highly stable diversely functionalized superparamagnetic iron oxide nanoparticles

    International Nuclear Information System (INIS)

    Bhattacharya, Dipsikha; Sahu, Sumanta K.; Banerjee, Indranil; Das, Manasmita; Mishra, Debashish; Maiti, Tapas K.; Pramanik, Panchanan

    2011-01-01

    In this article, we report the design and synthesis of a series of well-dispersed superparamagnetic iron oxide nanoparticles (SPIONs) using chitosan as a surface modifying agent to develop a potential T 2 contrast probe for magnetic resonance imaging (MRI). The amine, carboxyl, hydroxyl, and thiol functionalities were introduced on chitosan-coated magnetic probe via simple reactions with small reactive organic molecules to afford a series of biofunctionalized nanoparticles. Physico-chemical characterizations of these functionalized nanoparticles were performed by TEM, XRD, DLS, FTIR, and VSM. The colloidal stability of these functionalized iron oxide nanoparticles was investigated in presence of phosphate buffer saline, high salt concentrations and different cell media for 1 week. MRI analysis of human cervical carcinoma (HeLa) cell lines treated with nanoparticles elucidated that the amine-functionalized nanoparticles exhibited higher amount of signal darkening and lower T 2 relaxation in comparison to the others. The cellular internalization efficacy of these functionalized SPIONs was also investigated with HeLa cancer cell line by magnetically activated cell sorting (MACS) and fluorescence microscopy and results established selectively higher internalization efficacy of amine-functionalized nanoparticles to cancer cells. These positive attributes demonstrated that these nanoconjugates can be used as a promising platform for further in vitro and in vivo biological evaluations.

  4. Effects of glucagon-like peptide-1 on endothelial function in type 2 diabetes patients with stable coronary artery disease

    DEFF Research Database (Denmark)

    Nyström, Thomas; Gutniak, Mark K; Zhang, Qimin

    2004-01-01

    GLP-1 stimulates insulin secretion, suppresses glucagon secretion, delays gastric emptying, and inhibits small bowel motility, all actions contributing to the anti-diabetogenic peptide effect. Endothelial dysfunction is strongly associated with insulin resistance and type 2 diabetes mellitus...... and may cause the angiopathy typifying this debilitating disease. Therefore, interventions affecting both endothelial dysfunction and insulin resistance may prove useful in improving survival in type 2 diabetes patients. We investigated GLP-1's effect on endothelial function and insulin sensitivity (S......(I)) in two groups: 1) 12 type 2 diabetes patients with stable coronary artery disease and 2) 10 healthy subjects with normal endothelial function and S(I). Subjects underwent infusion of recombinant GLP-1 or saline in a random crossover study. Endothelial function was measured by postischemic FMD of brachial...

  5. Effects of Clopidogrel Therapy on Oxidative Stress, Inflammation, Vascular Function and Progenitor Cells in Stable Coronary Artery Disease

    Science.gov (United States)

    Ramadan, Ronnie; Dhawan, Saurabh S.; Syed, Hamid; Pohlel, F. Khan; Binongo, Jose Nilo G.; Ghazzal, Ziyad B.; Quyyumi, Arshed A.

    2014-01-01

    Background Traditional cardiovascular risk factors lead to endothelial injury and activation of leucocytes and platelets that initiate and propagate atherosclerosis. We proposed that clopidogrel therapy in patients with stable CAD imparts a pleiotropic effect that extends beyond anti-platelet aggregation to other athero-protective processes. Methods Forty-one subjects were randomized in a double-blind, placebo-controlled crossover study to either clopidogrel 75 mg daily or placebo for 6-weeks, and then transitioned immediately to the other treatment for an additional 6 weeks. We assessed 1) endothelial function as flow-mediated dilation of the brachial artery, 2) arterial stiffness and central augmentation index using applanation tonometry, 3) vascular function as fingertip reactive hyperemia index, 4) inflammation by measuring plasma CD40 ligand and serum high-sensitivity c-reactive protein levels, 5) oxidative stress by measuring plasma aminothiols, and 6) circulating progenitor cells, at baseline and at the end of each 6-week treatment period. Results Clopidogrel therapy resulted in a significant reduction in soluble CD40 ligand (p=0.03), a pro-thrombotic and pro-inflammatory molecule derived mainly from activated platelets. However, clopidogrel therapy had no effect on endothelial function, arterial stiffness, inflammatory and oxidative stress markers, or progenitor cells. Conclusions Our findings suggest a solitary anti-platelet effect of clopidogrel therapy in patients with stable CAD, with no effect on other sub-clinical markers of cardiovascular disease risk. PMID:24336012

  6. [Effect of L-arginine on platelet aggregation, endothelial function adn exercise tolerance in patients with stable angina pectoris].

    Science.gov (United States)

    Sozykin, A V; Noeva, E A; Balakhonova, T V; Pogorelova, O A; Men'shikov, M Iu

    2000-01-01

    Examination of the action of donor NO (L-arginine) on platelet aggregation, endothelial function and exercise tolerance in patients with stable angina of effort (SAE). 42 patients with SAE (functional class I-II) and 10 healthy volunteers (control group) were assigned to two groups. 22 patients of group 1 were randomized to cross-over. They received cardiket (60 mg/day for 10 days or cardiket (60 mg/day) in combination with L-arginine (15 g/day for 10 days). 20 SAE patients of group 2 and control group received L-arginine (15 g/day for 10 days). In each group blood lipids were examined, and bicycle exercise test (BET) was performed. In addition, platelet aggregation and endothelial function were studied in group 2 and control group before and after the course of L-arginine. Compared to control group, endothelial function significantly improved in group 2 (from 5.0 +/- 2.9 to 7.8 +/- 4.1% vs 7.1 +/- 1.9 to 6.6 +/- 4.8%) (M +/- SD). BET duration increased in all the patients. After ADP addition in concentrations 1.5, 2.0, and 5.0 micromol/l platelet aggregation declined in 17 patients except 3 in whom the aggregation remained unchanged. Positive effect of L-arginine on endothelial function, exercise tolerance and platelet aggregation was observed in patients with stable angina of effort (functional class I-II). Therefore, arginine can be recommended as an adjuvant in the treatment of patients with ischemic heart disease.

  7. Ball with hair: modular functionalization of highly stable G-quadruplex DNA nano-scaffolds through N2-guanine modification.

    Science.gov (United States)

    Lech, Christopher Jacques; Phan, Anh Tuân

    2017-06-20

    Functionalized nanoparticles have seen valuable applications, particularly in the delivery of therapeutic and diagnostic agents in biological systems. However, the manufacturing of such nano-scale systems with the consistency required for biological application can be challenging, as variation in size and shape have large influences in nanoparticle behavior in vivo. We report on the development of a versatile nano-scaffold based on the modular functionalization of a DNA G-quadruplex. DNA sequences are functionalized in a modular fashion using well-established phosphoramidite chemical synthesis with nucleotides containing modification of the amino (N2) position of the guanine base. In physiological conditions, these sequences fold into well-defined G-quadruplex structures. The resulting DNA nano-scaffolds are thermally stable, consistent in size, and functionalized in a manner that allows for control over the density and relative orientation of functional chemistries on the nano-scaffold surface. Various chemistries including small modifications (N2-methyl-guanine), bulky aromatic modifications (N2-benzyl-guanine), and long chain-like modifications (N2-6-amino-hexyl-guanine) are tested and are found to be generally compatible with G-quadruplex formation. Furthermore, these modifications stabilize the G-quadruplex scaffold by 2.0-13.3 °C per modification in the melting temperature, with concurrent modifications producing extremely stable nano-scaffolds. We demonstrate the potential of this approach by functionalizing nano-scaffolds for use within the biotin-avidin conjugation approach. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  8. Discrete Green’s function diakoptics for stable FDTD interaction between multiply-connected domains

    NARCIS (Netherlands)

    Hon, de B.P.; Arnold, J.M.; Graglia, R.D.

    2007-01-01

    We have developed FDTD boundary conditions based on discrete Green's function diakoptics for arbitrary multiply-connected 2D domains. The associated Z-domain boundary operator is symmetric, with an imaginary part that can be proved to be positive semi-definite on the upper half of the unit circle in

  9. A robust and rapid method of producing soluble, stable, and functional G-protein coupled receptors.

    Directory of Open Access Journals (Sweden)

    Karolina Corin

    Full Text Available Membrane proteins, particularly G-protein coupled receptors (GPCRs, are notoriously difficult to express. Using commercial E. coli cell-free systems with the detergent Brij-35, we could rapidly produce milligram quantities of 13 unique GPCRs. Immunoaffinity purification yielded receptors at >90% purity. Secondary structure analysis using circular dichroism indicated that the purified receptors were properly folded. Microscale thermophoresis, a novel label-free and surface-free detection technique that uses thermal gradients, showed that these receptors bound their ligands. The secondary structure and ligand-binding results from cell-free produced proteins were comparable to those expressed and purified from HEK293 cells. Our study demonstrates that cell-free protein production using commercially available kits and optimal detergents is a robust technology that can be used to produce sufficient GPCRs for biochemical, structural, and functional analyses. This robust and simple method may further stimulate others to study the structure and function of membrane proteins.

  10. The evolution of central securities depositaries in Europe: stable functions in a changing environment

    OpenAIRE

    Dominique Chabert; Gisèle Chanel-Reynaud

    2006-01-01

    National audience; Settlement-delivery (S&D) operations of CSDs or ICSDs are the second last stage of the securities treatment procedure, the last stage being the delivery of securities into the accounts of the final holders by their account managers/custodians. As for national transfers, the organisation is fairly simple since regional depositors are directly connected to the central securities depositary which fulfils two overriding functions on their behalf:- ensuring the final custody of ...

  11. A Dynamic Connectome Supports the Emergence of Stable Computational Function of Neural Circuits through Reward-Based Learning.

    Science.gov (United States)

    Kappel, David; Legenstein, Robert; Habenschuss, Stefan; Hsieh, Michael; Maass, Wolfgang

    2018-01-01

    Synaptic connections between neurons in the brain are dynamic because of continuously ongoing spine dynamics, axonal sprouting, and other processes. In fact, it was recently shown that the spontaneous synapse-autonomous component of spine dynamics is at least as large as the component that depends on the history of pre- and postsynaptic neural activity. These data are inconsistent with common models for network plasticity and raise the following questions: how can neural circuits maintain a stable computational function in spite of these continuously ongoing processes, and what could be functional uses of these ongoing processes? Here, we present a rigorous theoretical framework for these seemingly stochastic spine dynamics and rewiring processes in the context of reward-based learning tasks. We show that spontaneous synapse-autonomous processes, in combination with reward signals such as dopamine, can explain the capability of networks of neurons in the brain to configure themselves for specific computational tasks, and to compensate automatically for later changes in the network or task. Furthermore, we show theoretically and through computer simulations that stable computational performance is compatible with continuously ongoing synapse-autonomous changes. After reaching good computational performance it causes primarily a slow drift of network architecture and dynamics in task-irrelevant dimensions, as observed for neural activity in motor cortex and other areas. On the more abstract level of reinforcement learning the resulting model gives rise to an understanding of reward-driven network plasticity as continuous sampling of network configurations.

  12. Gold work function reduction by 2.2 eV with an air-stable molecular donor layer

    Energy Technology Data Exchange (ETDEWEB)

    Broeker, Benjamin; Blum, Ralf-Peter; Frisch, Johannes; Rabe, Juergen P.; Koch, Norbert [Institut fuer Physik, Humboldt-Universitaet zu Berlin (Germany); Vollmer, Antje [Berliner Elektronenspeicherring-Gesellschaft fuer Synchrotronstrahlung mbH, Berlin (Germany); Hofmann, Oliver T.; Zojer, Egbert [Institut of Solid State Physics, Graz University of Technology (Austria); Rieger, Ralph; Muellen, Klaus [Max Planck Institut fuer Polymerforschung, Mainz (Germany)

    2009-07-01

    Ultraviolet photoelectron spectroscopy was used to investigate neutral methyl viologen (1,1'-dimethyl-1H,1'H-[4,4']bipyridinylidene, MV0) deposited on Au(111) surfaces. As a result of molecule-to-metal electron transfer, the work function of Au(111) was decreased from 5.5 eV to 3.3 eV. The energy levels of electron transport layers deposited on top of modified Au surfaces were shifted to higher binding energy compared to layers on pristine Au, and the electron injection barrier was reduced by 0.8 eV for tris(8-hydroxyquinoline)aluminum (Alq3) and by 0.7 eV for C60. The air-stable donor MV0 can thus be used to facilitate electron injection into organic semiconductors even from high work function metals.

  13. Ion transport properties of mechanically stable symmetric ABCBA pentablock copolymers with quaternary ammonium functionalized midblock

    Energy Technology Data Exchange (ETDEWEB)

    Ertem, S. Piril [Department of Polymer Science and Engineering, University of Massachusetts Amherst, 120 Governors Drive Amherst Massachusetts 01003; Caire, Benjamin R. [Department of Chemical and Biological Engineering, Colorado School of Mines, Golden Colorado 80401; Tsai, Tsung-Han [Department of Polymer Science and Engineering, University of Massachusetts Amherst, 120 Governors Drive Amherst Massachusetts 01003; Zeng, Di [Department of Polymer Science and Engineering, University of Massachusetts Amherst, 120 Governors Drive Amherst Massachusetts 01003; Vandiver, Melissa A. [Department of Chemical and Biological Engineering, Colorado School of Mines, Golden Colorado 80401; Kusoglu, Ahmet [Energy Conversion Group, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley California 94720; Seifert, Soenke [Energy Conversion Group, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley California 94720; Hayward, Ryan C. [Department of Polymer Science and Engineering, University of Massachusetts Amherst, 120 Governors Drive Amherst Massachusetts 01003; Weber, Adam Z. [Energy Conversion Group, Energy Technologies Area, Lawrence Berkeley National Laboratory, Berkeley California 94720; Herring, Andrew M. [Department of Chemical and Biological Engineering, Colorado School of Mines, Golden Colorado 80401; Coughlin, E. Bryan [Department of Polymer Science and Engineering, University of Massachusetts Amherst, 120 Governors Drive Amherst Massachusetts 01003; Liberatore, Matthew W. [Department of Chemical Engineering Department, University of Toledo, 2801 W Bancroft Street MS305 Toledo Ohio 43606

    2017-02-07

    Anion exchange membranes (AEMs) are a promising class of materials for applications that require selective ion transport, such as fuel cells, water purification, and electrolysis devices. Studies of structure–morphology–property relationships of ion-exchange membranes revealed that block copolymers exhibit improved ion conductivity and mechanical properties due to their microphase-separated morphologies with well-defined ionic domains. While most studies focused on symmetric diblock or triblock copolymers, here, the first example of a midblock quaternized pentablock AEM is presented. A symmetric ABCBA pentablock copolymer was functionalized to obtain a midblock brominated polymer. Solution cast films were then quaternized to obtain AEMs with resulting ion exchange capacities (IEC) ranging from 0.4 to 0.9 mmol/g. Despite the relatively low IEC, the polymers were highly conductive (up to 60 mS/cm Br2 at 90 8C and 95%RH) with low water absorption (<25 wt %) and maintained adequate mechanical properties in both dry and hydrated conditions. Xray scattering and transmission electron microscopy (TEM) revealed formation of cylindrical non-ionic domains in a connected ionic phase.

  14. Understanding the Formation of Kinetically Stable Compounds and the Development of Thin Film Pair Distribution Function Analysis

    Science.gov (United States)

    Wood, Suzannah Rebecca

    Navigating the synthesis landscape poses many challenges when developing novel solid state materials. Advancements in both synthesis and characterization are necessary to facilitate the targeting of specific materials. This dissertation discusses the formation of chalcogenide heterostructures and their properties in the first part and the development of thin film pair distribution function analysis (tfPDF) in the second part. The heterostructures were formed by the self-assembly of designed precursors deposited by physical vapor deposition in a modulated elemental reactants approach, which provides the control and predictability to synthesis. Specifically, a series of (BiSe)1+delta(TiSe2) n, where n = 2,3,&4, were synthesized to explore the extent of charge transfer from the BiSe to TiSe2 layers. To further explore the role Bi plays in charge donation, a family of structurally similar compounds, (Bix Sn1-xSe)1+deltaTiSe2, where 0≥x≥1, were synthesized and characterized. Electrical measurements show doping efficiency decreases as x increases, correlated with the structural distortion and the formation of periodic antiphase boundaries containing Bi-Bi pairs. The first heterostructures composed of three unique structural types were synthesized and Bi2Se3 layer thickness was used to tune electrical properties and further explore charge transfer. To better understand the potential energy landscape on which these kinetically stable compounds exist, two investigations were undertaken. The first was a study of the formation and subsequent decomposition of [(BiSe)1+delta]n(TiSe2)n compounds, where n= 2&3, the second an investigation of precursor structure for thermodynamically stable FeSb2 and kinetically stable FeSb3. The second section describes the development of thin film pair distribution function analysis, a technique in which total scattering data for pair distribution function (PDF) analysis is obtained from thin films, suitable for local structure analysis

  15. Lung needle biopsy

    Science.gov (United States)

    ... if you have certain lung diseases such as emphysema. Usually, a collapsed lung after a biopsy does not need treatment. But ... any type Bullae (enlarged alveoli that occur with emphysema) Cor pulmonale (condition ... of the lung High blood pressure in the lung arteries Severe ...

  16. Closed Pericardial Biopsy

    African Journals Online (AJOL)

    1974-09-28

    Sep 28, 1974 ... The instrument used is a hook biopsy needle (Fig. I). manufactured by Becton, Dickinson and Co., Rutherford,. New Jersey, USA. The instrument' and technique' will be reviewed. The instrument consists of an ll-gauge needle with a sharp cutting edge into which fits, interchangeably, a 13-gauge needle or a ...

  17. CONE BIOPSY IN PREGNANCY*

    African Journals Online (AJOL)

    1 Mei 1971. S.-A. TYDSKRIF VIR OBSTETRIE EN GINEKOLOGIE. CONE BIOPSY ... of the abnormal cervix in pregnancy is also no longer in question following the .... the concept of cancer prophylaxis to the majority of women, many of whom ...

  18. Robust and Stable Disturbance Observer of Servo System for Low Speed Operation Using the Radial Basis Function Network

    DEFF Research Database (Denmark)

    Lee, Kyo-Beum; Blaabjerg, Frede

    2005-01-01

    A new scheme to estimate the moment of inertia in the servo motor drive system in very low speed is proposed in this paper. The speed estimation scheme in most servo drive systems for low speed operation is sensitive to the variation of machine parameter, especially the moment of inertia....... To estimate the motor inertia value, the observer using the Radial Basis Function Network (RBFN) is applied. A control law for stabilizing the system and adaptive laws for updating both of the weights in the RBFN and a bounding constant are established so that the whole closed-loop system is stable...... in the sense of Lyapunov. The effectiveness of the proposed inertia estimation is verified by simulations and experiments. It is concluded that the speed control performance in low speed region is improved with the proposed disturbance observer using RBFN....

  19. Transbronchial biopsies safely diagnose amyloid lung disease

    Science.gov (United States)

    Govender, Praveen; Keyes, Colleen M.; Hankinson, Elizabeth A.; O’Hara, Carl J.; Sanchorawala, Vaishali; Berk, John L.

    2018-01-01

    Background Autopsy identifies lung involvement in 58–92% of patients with the most prevalent forms of systemic amyloidoses. In the absence of lung biopsies, amyloid lung disease often goes unrecognized. Report of a death following transbronchial biopsies in a patient with systemic amyloidosis cautioned against the procedure in this patient cohort. We reviewed our experience with transbronchial biopsies in patients with amyloidosis to determine the safety and utility of bronchoscopic lung biopsies. Methods We identified patients referred to the Amyloidosis Center at Boston Medical Center with lung amyloidosis diagnosed by transbronchial lung biopsies (TBBX). Amyloid typing was determined by immunohistochemistry or mass spectrometry. Standard end organ assessments, including pulmonary function test (PFT) and chest tomography (CT) imaging, and extra-thoracic biopsies established the extent of disease. Results Twenty-five (21.7%) of 115 patients with lung amyloidosis were diagnosed by TBBX. PFT classified 33.3% with restrictive physiology, 28.6% with obstructive disease, and 9.5% mixed physiology; 9.5% exhibited isolated diffusion defects while 19% had normal pulmonary testing. Two view chest or CT imaging identified focal opacities in 52% of cases and diffuse interstitial disease in 48%. Amyloid type and disease extent included 68% systemic AL disease, 16% localized (lung limited) AL disease, 12% ATTR disease, and 4% AA amyloidosis. Fluoroscopy was not used during biopsy. No procedure complications were reported. Conclusions Our case series of 25 patients supports the use of bronchoscopic transbronchial biopsies for diagnosis of parenchymal lung amyloidosis. Normal PFTs do not rule out the histologic presence of amyloid lung disease. PMID:28393574

  20. High-resolution stable isotope monitoring reveals differential vegetation-soil water feedbacks among plant functional types

    Science.gov (United States)

    Volkmann, T. H. M.; Haberer, K.; Troch, P. A. A.; Gessler, A.; Weiler, M.

    2016-12-01

    Understanding the linked dynamics of rain water recharge to soils and its utilization by plants is critical for predicting the impact of climate and land use changes on the productivity of ecosystems and the hydrologic cycle. While plants require vast quantities of water from the soil to sustain growth and function, they exert important direct and indirect controls on the movement of water through the rooted soil horizons, thereby potentially affecting their own resource availability. However, the specific ecohydrological belowground processes associated with different plant types and their rooting systems have been difficult to quantify with traditional methods. Here, we report on the use of techniques for monitoring stable isotopes in soil and plant water pools that allow us to track water infiltration and root uptake dynamics non-destructively and in high resolution. The techniques were applied in controlled rain pulse experiments with distinct plant types (grass, deciduous trees, grapevine) that we let develop on an initially uniform soil for two years. Our results show that plant species and types differed widely in their plasticity and pattern of root uptake under variable water availability. Thereby, and through notably co-acting indirect effects related to differential root system traits and co-evolution of soil properties, the different plants induced contrasting hydrological dynamics in the soil they had inhabited for only a short period of time. Taken together, our data suggest that the studied soil-vegetation systems evolved a positive infiltration-uptake feedback in which hydrological flow pathways underlying different species diverged in a way that complemented their specific water utilization strategy. Such a feedback could present an indirect competitive mechanism by which plants improve their own water supply and modulate hydrological cycling at the land surface. The ability to directly measure this feedback using in situ isotope methodology

  1. Characterization of para-Nitrophenol-Degrading Bacterial Communities in River Water by Using Functional Markers and Stable Isotope Probing.

    Science.gov (United States)

    Kowalczyk, Agnieszka; Eyice, Özge; Schäfer, Hendrik; Price, Oliver R; Finnegan, Christopher J; van Egmond, Roger A; Shaw, Liz J; Barrett, Glyn; Bending, Gary D

    2015-10-01

    Microbial degradation is a major determinant of the fate of pollutants in the environment. para-Nitrophenol (PNP) is an EPA-listed priority pollutant with a wide environmental distribution, but little is known about the microorganisms that degrade it in the environment. We studied the diversity of active PNP-degrading bacterial populations in river water using a novel functional marker approach coupled with [(13)C6]PNP stable isotope probing (SIP). Culturing together with culture-independent terminal restriction fragment length polymorphism analysis of 16S rRNA gene amplicons identified Pseudomonas syringae to be the major driver of PNP degradation in river water microcosms. This was confirmed by SIP-pyrosequencing of amplified 16S rRNA. Similarly, functional gene analysis showed that degradation followed the Gram-negative bacterial pathway and involved pnpA from Pseudomonas spp. However, analysis of maleylacetate reductase (encoded by mar), an enzyme common to late stages of both Gram-negative and Gram-positive bacterial PNP degradation pathways, identified a diverse assemblage of bacteria associated with PNP degradation, suggesting that mar has limited use as a specific marker of PNP biodegradation. Both the pnpA and mar genes were detected in a PNP-degrading isolate, P. syringae AKHD2, which was isolated from river water. Our results suggest that PNP-degrading cultures of Pseudomonas spp. are representative of environmental PNP-degrading populations. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  2. From Turnover-Oriented to Functional Soil Organic Matter Pools: a Lesson Learned from Stable Isotope Tracing

    Science.gov (United States)

    Cotrufo, M. F.

    2016-12-01

    Globally soils contain three times the amount of carbon (C) stored in the atmosphere, and 68% of this is stored in soil below 30cm. Changes to the size of the soil C stocks could significantly impact the net terrestrial-atmosphere CO2 exchange and thus either mitigate or increase concentrations of CO2. Yet we are currently unable to conduct reliable predictions of the direction and magnitude of soil C stock changes, since current soil C models fail to accurately capture the current understanding of how soil organic matter (SOM) forms and persists, and (2) the vertical movement and deep soil processing of SOM. We propose shifting soil C modelling approaches from a turnover-oriented approach to a more functional-oriented approach, where measurable SOM pools with specific function in soils, with respect to their physical structure (soluble versus particulate), microbial accessibility (free versus mineral or aggregate protection) and ability to transfer along the soil profile (through water flow or by mass transport) are represented. We will present experimental evidence from a number of studies conducted in the past few years using stable isotope tracing in support of incorporating a dissolved organic matter (DOM)-microbial path and a physical transfer of particulate organic matter path in SOM models. We will also show how, through the DOM-microbial path, fresh plant inputs quickly result in the formation of new mineral-associated organic matter.

  3. Image-Guided percutaneous biopsies with a biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Lim, Hyo Keun; Kim, Eun Ah; Yun, Ku Sub; Bae, Sang Hoo; Shin, Hyung Sik [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1994-07-15

    We report the results of image-guided percutaneous biopsies with a biopsy gun and evaluate the clinical usefulness. One hundred and five biopsies under ultrasonographic or fluoroscopic guidance were performed. Various anatomic sites were targeted(liver; 50, chest; 22, kidney; 12, pancreas; 8, intraperitoeum; 7, retroperitoneum; ). Obtained tissue was diagnostic in 98 of the 105 biopsies(93%). In each instance, representative core tissue specimens were obtained. Evaluation of the core tissue by pathologist revealed consistent, uniform specimens that contained significant crush artifact in no case. Five biopsies yielded inadequate tissue which were too small for histopathologic interpretation or were composed of necrotic debris. Two biopsies yielded adequate tissues, but tissues were not of the target. The diagnoses were malignancy in 77 biopsies and benign disease in 21 biopsies. No complications other than mild, localized discomfort were encountered except a transient hemoptysis and pneumothorax which was observed in two patients. Cutting biopsy with a biopsy gun provided sufficient amount of target tissue for an accurate diagnosis of malignant and benign disease. It was a safe and useful procedure for percutaneous biopsy.

  4. Radiologically Guided Bone Biopsy: Results of 502 Biopsies

    International Nuclear Information System (INIS)

    Ng, Chaan S.; Salisbury, Jonathan R.; Darby, Alan J.; Gishen, Philip

    1998-01-01

    Purpose: To analyze the results of 502 biopsies over a 19-year period for the purpose of highlighting the results that can be expected from such a large study, with emphasis on needle choice and anesthetic methods. Methods: The histological, cytological, and microbiological results of 477 patients who had 502 bone biopsies carried out between July 1977 and March 1996 were studied. Less than 5% of patients required second biopsies. There were almost equal numbers of males and females in the group. The lesions were visible radiologically and most of the biopsies were carried out by a single operator. The lesions were classified on their histopathological, cytopathological, and microbiological findings. Results: Tumors accounted for 40% of the biopsies, and infection for 16%. Biopsies which did not yield a 'positive' diagnosis accounted for 31%; these included specimens reported as normal, or as showing reactive changes, repair, remodelling, non-specific features, inflammation (but not clearly infective), or no evidence of malignancy or inflammation. Less than 4% of biopsies were incorrect, and some of these were re-biopsied. Conclusion: Bone biopsy is a valuable technique for positive diagnosis of malignancy or infection, as it enables a definitive plan for treatment and management of patients to be established. Exclusion of serious pathology is almost equally important. In principle, any osseous site can be biopsied using fluoroscopic or computed tomographic guidance. Care in the biopsy technique and selection of the bone needle is required

  5. US-guided percutaneous biopsies with a biopsy gun

    International Nuclear Information System (INIS)

    Ahn, In Oak; Kim, Hyung Jin; Kim, Jae Hyung; Lee, Goo; Jung, Sung Hoon

    1993-01-01

    Core tissue for histologic study is believed by many pathologist to be more diagnostic than material from needle aspiration. Recently introduced automatched biopsy gun simplifies core biopsies with increased quantity and quality of samples. Authors performed 38 percutaneous biopsies from 38 patients with 18G automated biopsy guns under US guide. Diagnostic target tissues were obtained in 33 biopsies(87%), inadequate tissues in 4(11%), and adequate but not of target tissue in 1(3%). There was no major complication requiring treatment, but pain needing analgesics and pain with nausea/vomiting were experienced in 2 and 1 biopsies respectively. Average number of needle passes was 1.5. We concluded that US guided gun biopsy was a easy and safe way to obtain tissue samples of good quantity and quality, especially useful in hospitals without constant availability of specialist in cytopathology

  6. Usefulness of automated biopsy guns in image-guided biopsy

    International Nuclear Information System (INIS)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi

    1994-01-01

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis

  7. Usefulness of automated biopsy guns in image-guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi [School of Medicine, Keimyung University, Daegu (Korea, Republic of)

    1994-12-15

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis.

  8. Telepathology and Optical Biopsy

    Directory of Open Access Journals (Sweden)

    Olga Ferrer-Roca

    2009-01-01

    Full Text Available The ability to obtain information about the structure of tissue without taking a sample for pathology has opened the way for new diagnostic techniques. The present paper reviews all currently available techniques capable of producing an optical biopsy, with or without morphological images. Most of these techniques are carried out by physicians who are not specialized in pathology and therefore not trained to interpret the results as a pathologist would. In these cases, the use of telepathology or distant consultation techniques is essential.

  9. No need for biopsies

    DEFF Research Database (Denmark)

    Gjødsbøl, Kristine; Skindersoe, Mette E; Christensen, Jens Jørgen

    2011-01-01

    collected. After 4 weeks, additional biopsy and filter paper pad samples were collected. Bacteria were isolated and identified at species level by standard methods. The most common bacterial species detected was Staphylococcus aureus found in 89% of the ulcers. No methicillin-resistant S. aureus isolates...... were found. We did not find any significant differences regarding the bacterial species isolated between the three sampling techniques. However, using multiple techniques led to identification of more species. Our study suggests that it is sufficient to use swab specimens to identify the bacterial...

  10. Functional connectivity of coral reef fishes in a tropical seascape assessed by compound-specific stable isotope analyses

    KAUST Repository

    McMahon, Kelton W.

    2011-01-01

    The ecological integrity of tropical habitats, including mangroves, seagrass beds and coral reefs, is coming under increasing pressure from human activities. Many coral reef fish species are thought to use mangroves and seagrass beds as juvenile nurseries before migrating to coral reefs as adults. Identifying essential habitats and preserving functional linkages among these habitats is likely necessary to promote ecosystem health and sustainable fisheries on coral reefs. This necessitates quantitative assessment of functional connectivity among essential habitats at the seascape level. This thesis presents the development and first application of a method for tracking fish migration using amino acid (AA) δ13C analysis in otoliths. In a controlled feeding experiment with fish reared on isotopically distinct diets, we showed that essential AAs exhibited minimal trophic fractionation between consumer and diet, providing a δ13C record of the baseline isoscape. We explored the potential for geochemical signatures in otoliths of snapper to act as natural tags of residency in seagrass beds, mangroves and coral reefs in the Red Sea, Caribbean Sea and Eastern Pacific Ocean. The δ13C values of otolith essential AAs varied as a function of habitat type and provided a better tracer of residence in juvenile nursery habitats than conventional bulk stable isotope analyses (SIA). Using our otolith AA SIA approach, we quantified the relative contribution of coastal wetlands and reef habitats to Lutjanus ehrenbergii populations on coastal, shelf and oceanic coral reefs in the Red Sea. L. ehrenbergii made significant ontogenetic migrations, traveling more than 30 km from juvenile nurseries to coral reefs and across deep open water. Coastal wetlands were important nurseries for L. ehrenbergii; however, there was significant plasticity in L. ehrenbergii juvenile habitat requirements. Seascape configuration played an important role in determining the functional connectivity of L

  11. Morphological pattern of endometrial biopsies in southwestern Nigeria

    African Journals Online (AJOL)

    Background: Endometrium remains the most sensitive indicator of ovarian function and endometrial biopsy is one of the diagnostic procedures in endometrial pathology. The current study was carried out to examine the morphological pattern of endometrial biopsies in Ibadan, South-western Nigeria and compare the results ...

  12. Food web functioning of the benthopelagic community in a deep-sea seamount based on diet and stable isotope analyses

    Science.gov (United States)

    Preciado, Izaskun; Cartes, Joan E.; Punzón, Antonio; Frutos, Inmaculada; López-López, Lucía; Serrano, Alberto

    2017-03-01

    Trophic interactions in the deep-sea fish community of the Galicia Bank seamount (NE Atlantic) were inferred by using stomach contents analyses (SCA) and stable isotope analyses (SIA) of 27 fish species and their main prey items. Samples were collected during three surveys performed in 2009, 2010 and 2011 between 625 and 1800 m depth. Three main trophic guilds were determined using SCA data: pelagic, benthopelagic and benthic feeders, respectively. Vertically migrating macrozooplankton and meso-bathypelagic shrimps were identified to play a key role as pelagic prey for the deep sea fish community of the Galicia Bank. Habitat overlap was hardly detected; as a matter of fact, when species coexisted most of them evidenced a low dietary overlap, indicating a high degree of resource partitioning. A high potential competition, however, was observed among benthopelagic feeders, i.e.: Etmopterus spinax, Hoplostethus mediterraneus and Epigonus telescopus. A significant correlation was found between δ15N and δ13C for all the analysed species. When calculating Trophic Levels (TLs) for the main fish species, using both the SCA and SIA approaches, some discrepancies arose: TLs calculated from SIA were significantly higher than those obtained from SCA, probably indicating a higher consumption of benthic-suprabenthic prey in the previous months. During the summer, food web functioning in the Galicia Bank was more influenced by the assemblages dwelling in the water column than by deep-sea benthos, which was rather scarce in the summer samples. These discrepancies demonstrate the importance of using both approaches, SCA (snapshot of diet) and SIA (assimilated food in previous months), when attempting trophic studies, if an overview of food web dynamics in different compartments of the ecosystem is to be obtained.

  13. Prevalence of renal dysfunction and its influence on functional capacity in elderly patients with stable chronic heart failure

    Directory of Open Access Journals (Sweden)

    Stanojević Dragana

    2012-01-01

    Full Text Available Bacground/Aim. Chronic heart failure (CHF is highly prevalent and constitutes an important public health problem around the world. In spite of a large number of pharmacological agents that successfully decrease mortality in CHF, the effects on exercise tolerance and quality of life are modest. Renal dysfunction is extremely common in patients with CHF and it is strongly related not only to increased mortality and morbidity but to a significant decrease in exercise tolerance, as well. The aim of our study was to investigate the prevalence and influence of the renal dysfunction on functional capacity in the elderly CHF patients. Methods. We included 127 patients aged over 65 years in a stable phase of CHF. The diagnosis of heart failure was based on the latest diagnostic principles of the European Society of Cardiology. The estimated glomerular filtration rate (eGRF was determined by the abbreviated Modification of Diet in Renal Disease (MDRD2 formula, and patients were categorized using the Kidney Disease Outcomes Quality Initiative (K/DOQI classification system. Functional capacity was determined by the 6 minute walking test (6MWT. Results. Among 127 patients, 90 were men. The average age was 72.5 ± 4.99 years and left ventricular ejection fraction (LVEF was 40.22 ± 9.89%. The average duration of CHF was 3.79 ± 4.84 years. Ninty three (73.2% patients were in New York Heart Association (NYHA class II and 34 (26.8% in NYHA class III. Normal renal function (eGFR ≥ 90 mL/min had 8.9% of participants, 57.8% had eGFR between 60-89 mL/min (stage 2 or mild reduction in GFR according to K/DOQI classification, 32.2% had eGFR between 30-59 mL/min (stage 3 or moderate reduction in GFR and 1.1% had eGFR between 15-29 mL/min (stage 4 or severe reduction in GFR. We found statistically significant correlation between eGFR and 6 minute walking distance (6MWD (r = 0.390, p < 0.001, LVEF (r = 0.268, p < 0.05, NYHA class (ς = -0.269, p < 0.05 and age (r = - 0

  14. Monin-Obukhov Similarity Functions of the Structure Parameter of Temperature and Turbulent Kinetic Energy Dissipation Rate in the Stable Boundary Layer

    NARCIS (Netherlands)

    Hartogensis, O.K.; Debruin, H.A.R.

    2005-01-01

    The Monin-Obukhov similarity theory (MOST) functions fepsi; and fT, of the dissipation rate of turbulent kinetic energy (TKE), ¿, and the structure parameter of temperature, CT2, were determined for the stable atmospheric surface layer using data gathered in the context of CASES-99. These data cover

  15. Stable isotopes

    International Nuclear Information System (INIS)

    Evans, D.K.

    1986-01-01

    Seventy-five percent of the world's stable isotope supply comes from one producer, Oak Ridge Nuclear Laboratory (ORNL) in the US. Canadian concern is that foreign needs will be met only after domestic needs, thus creating a shortage of stable isotopes in Canada. This article describes the present situation in Canada (availability and cost) of stable isotopes, the isotope enrichment techniques, and related research programs at Chalk River Nuclear Laboratories (CRNL)

  16. Endoscopic biopsies in Ussing chambers evaluated for studies of macromolecular permeability in the human colon.

    Science.gov (United States)

    Wallon, Conny; Braaf, Ylva; Wolving, Mats; Olaison, Gunnar; Söderholm, Johan D

    2005-05-01

    Studies of mucosal permeability to protein antigens in humans are limited to in vitro techniques. The use of surgical specimens for such studies has major shortcomings. Endoscopic biopsies in Ussing chambers have been introduced as a means of studying secretion and transepithelial permeability, but have not been evaluated for studies of protein antigen uptake in human intestine. Standard forceps biopsies from the sigmoid colon of 24 healthy volunteers were mounted in Ussing chambers with an exposed tissue area of 1.76 mm2. 51Cr-EDTA (paracellular probe) and horseradish peroxidase (HRP; 45 kDa protein antigen) were used as permeability markers. Mucosal permeability, electrophysiology, histology and energy contents of the biopsies were studied over time. To evaluate the ability of the technique to detect permeability changes, the mucosa was modulated with capric acid, a medium-chain fatty acid, known to affect tight junctions. In the Ussing chamber the mucosal biopsies were viable for 160 min with stable levels of ATP and lactate, and only minor changes in morphology. Steady-state permeability with low variability was seen for both markers during the 30-90 min period. Exposure to capric acid induced a rapid decrease in short-circuit current (Isc) and a slower reversible decrease in transepithelial resistance (TER), as well as an increased permeability to 51Cr-EDTA and HRP. Endoscopic biopsies of human colon are viable in Ussing chambers and are reliable tools for studies of mucosal permeability to protein antigens. The technique offers a broad potential for studies of mucosal function in the pathophysiology of human gastrointestinal diseases.

  17. Oral Biopsy: A Dental Gawk

    African Journals Online (AJOL)

    Sir,. Dermatologists are often confronted with neoplasms and diseases of the oral cavity. Although many may be reluctant to perform oral surgical procedures, a biopsy is often needed to establish a definitive diagnosis, and biopsy of the oral cavity is a safe and useful technique that can be easily employed by dermatologists.

  18. The accuracy of colposcopic biopsy

    DEFF Research Database (Denmark)

    Stoler, Mark H; Vichnin, Michelle D; Ferenczy, Alex

    2011-01-01

    We evaluated the overall agreement between colposcopically directed biopsies and the definitive excisional specimens within the context of three clinical trials. A total of 737 women aged 16-45 who had a cervical biopsy taken within 6 months before their definitive therapy were included. Per-prot...

  19. Liquid biopsy for brain tumors

    Science.gov (United States)

    Shankar, Ganesh M.; Balaj, Leonora; Stott, Shannon L.; Nahed, Brian; Carter, Bob S.

    2018-01-01

    Introduction Minimally invasive methods will augment the clinical approach for establishing the diagnosis or monitoring treatment response of central nervous system tumors. Liquid biopsy by blood or cerebrospinal fluid sampling holds promise in this regard. Areas covered In this literature review, the authors highlight recent studies describing the analysis of circulating tumor cells, cell free nucleic acids, and extracellular vesicles as strategies to accomplish liquid biopsy in glioblastoma and metastatic tumors. The authors then discuss the continued efforts to improve signal detection, standardize the liquid biopsy handling and preparation, develop platforms for clinical application, and establish a role for liquid biopsies in personalized medicine. Expert commentary As the technologies used to analyze these biomarkers continue to evolve, we propose that there is a future potential to precisely diagnose and monitor treatment response with liquid biopsies. PMID:28875730

  20. Colloid stable sorbents for cesium removal: Preparation and application of latex particles functionalized with transition metals ferrocyanides

    Energy Technology Data Exchange (ETDEWEB)

    Avramenko, Valentin [Institute of Chemistry, Far Eastern Branch, Russian Academy of Sciences, 159 ave 100-letiya Vladivostoka, Vladivostok 690022 (Russian Federation); Bratskaya, Svetlana, E-mail: sbratska@ich.dvo.ru [Institute of Chemistry, Far Eastern Branch, Russian Academy of Sciences, 159 ave 100-letiya Vladivostoka, Vladivostok 690022 (Russian Federation); Zheleznov, Veniamin; Sheveleva, Irina [Institute of Chemistry, Far Eastern Branch, Russian Academy of Sciences, 159 ave 100-letiya Vladivostoka, Vladivostok 690022 (Russian Federation); Voitenko, Oleg [Far Eastern Federal University, Laboratory of Electron Microscopy and Image Processing, 27, Oktyabr' skaya Street, Vladivostok 690950 (Russian Federation); Sergienko, Valentin [Institute of Chemistry, Far Eastern Branch, Russian Academy of Sciences, 159 ave 100-letiya Vladivostoka, Vladivostok 690022 (Russian Federation)

    2011-02-28

    In this paper we suggest a principally new approach to preparation of colloid stable selective sorbents for cesium uptake using immobilization of transition metals (cobalt, nickel, and copper) ferrocyanides in nanosized carboxylic latex emulsions. The effects of ferrocyanide composition, pH, and media salinity on the sorption properties of the colloid stable sorbents toward cesium ions were studied in solutions containing up to 200 g/L of sodium nitrate or potassium chloride. The sorption capacities of the colloid sorbents based on mixed potassium/transition metals ferrocyanides were in the range 1.3-1.5 mol Cs/mol ferrocyanide with the highest value found for the copper ferrocyanide. It was shown that the obtained colloid-stable sorbents were capable to penetrate through bulk materials without filtration that made them applicable for decontamination of solids, e.g. soils, zeolites, spent ion-exchange resins contaminated with cesium radionuclides. After decontamination of liquid or solid radioactive wastes the colloid-stable sorbents can be easily separated from solutions by precipitation with cationic flocculants providing localization of radionuclides in a small volume of the precipitates formed.

  1. Trophodynamics and functional feeding groups of North Sea fauna: a combined stable isotope and fatty acid approach

    NARCIS (Netherlands)

    Kürten, B.; Frutos, I.; Struck, U.; Painting, S.J.; Polunin, N.V.C.; Middelburg, J.J.

    The trophodynamics of pelagic and benthic animals of the North Sea, North Atlantic shelf, were assessed using stable isotope analysis (SIA) of natural abundance carbon and nitrogen isotopes, lipid fingerprinting and compound-specific SIA (CSIA) of phospholipid-derived fatty acids (PLFAs).

  2. Trophodynamics and functional feeding groups of North Sea fauna: a combined stable isotope and fatty acid approach

    NARCIS (Netherlands)

    Kürten, B.; Frutos, I.; Struck, U.; Painting, S.J.; Polunin, N.V.C.; Middelburg, J.J.

    2013-01-01

    The trophodynamics of pelagic and benthic animals of the North Sea, North Atlantic shelf, were assessed using stable isotope analysis (SIA) of natural abundance carbon and nitrogen isotopes, lipid fingerprinting and compound-specific SIA (CSIA) of phospholipid-derived fatty acids (PLFAs).

  3. PATHOMORPHOLOGY OF ZERO BIOPSIES OF DONOR KIDNEYS

    Directory of Open Access Journals (Sweden)

    M. L. Arefjev

    2011-01-01

    Full Text Available There is well known fact that kidney transplants from Extended Criteria Donors may increase risk of De- layed Graft Function and Primary Non-Function of transplants. We have collected and tested 65 «zero» kidney biopsies from cadaver donors aged from 19 to 71 years old. In the pool of elderly donors who died from cerebrovascular accident the frequency of nephrosclerosis presentation was higher than in donors of yonger age who died from craniocephalic trauma. Nevertheless in the general donor pool the number of sclerosed glomeruli was no more than 12%. We did not meet at all in the whole volume of material any bi- opsy with the severe degree of arteriosclerosis. The «zero» biopsies of cadaver kidneys is quite usable and unexpensive tool to measure the degree of nephrosclerosis in order to exclude kidneys which are not fitable for transplantation. 

  4. Mammographic scar for stereotaxic biopsy

    International Nuclear Information System (INIS)

    Guzman Tattis; Hincapie U, Ana Lucia; Patino P, Jairo Hernando

    1997-01-01

    It is reported the case of 56 years old woman who underwent a stereotactic biopsy because of having a circumscribed breast nodule. The histologic diagnosis was benign. After six months, during the mammographic control, it was noticed that the nodule showed irregular contours, because of that a surgical biopsy was performed. The histopathology was reported as benign. it is considered then, that the mammographic changes observed in the mammographic control are due to scar phenomenon after stereotactic biopsy. This findings has not been reported previously

  5. Ultraviolet-fluorescent tattoo location of cutaneous biopsy site.

    Science.gov (United States)

    Chuang, Gary S; Gilchrest, Barbara A

    2012-03-01

    Cutaneous biopsies often heal with little or no scarring. Prior studies have shown an alarming percentage of patients who incorrectly identify biopsy sites at the time of surgery. To investigate the safety and utility of an ultraviolet (UV)-fluorescent tattoo for biopsy site identification. A preclinical proof of concept was established with skin culture. An UV-fluorescent tattoo was applied to discarded neonatal foreskin in culture medium. The stability of the tattooed skin was examined clinically and histologically. One patient with a recurrent basal cell carcinoma in a difficult-to-identify location underwent tattoo application at the time of biopsy to demarcate the site. The patient was monitored for tattoo reaction and referred for surgical excision. The cultured tissue exhibited stable UV fluorescence with daily washing. Tissue histology demonstrated tattoo particles lining the skin edge under fluorescent microscopy. The patient was reluctant to undergo another surgical procedure and instead returned to our clinic at 3 months and 17 months after the biopsy for management of other tumors. The patient had no symptoms of allergic reaction to the tattoo dye. The fluorescent tattoo remains invisible under visible light and visible only under Wood's light. The present study documents the utility of an UV-fluorescent tattoo to locate a biopsy site. © 2011 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  6. Ultrasound-Guided Breast Biopsy

    Science.gov (United States)

    ... over time. top of page What are the benefits vs. risks? Benefits The procedure is less invasive than surgical biopsy, ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  7. X-ray guided biopsy

    International Nuclear Information System (INIS)

    Casanova, R.; Lezana, A.H.; Pedrosa, C.S.

    1980-01-01

    Fine needle aspiration biopsy (FNAB) is now a routine procedure in many X-ray Departments. This paper presents the authors' experience with this technique in chest, abdominal and skeletal lesions. (Auth.)

  8. Stereotactic (Mammographically Guided) Breast Biopsy

    Science.gov (United States)

    ... over time. top of page What are the benefits vs. risks? Benefits The procedure is less invasive than surgical biopsy, ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  9. Testicular biopsy in prepubertal boys

    DEFF Research Database (Denmark)

    Faure, Alice; Bouty, Aurore; O'Brien, Mike

    2016-01-01

    No consensus exists regarding the precise role of testicular biopsy in prepubertal boys, although it is considered useful for assessing the potential consequences of undescended testes on fertility. Current scientific knowledge indicates that surgeons should broaden indications for this procedure...... for the preservation of fertility after gonadotoxic chemotherapy - even for prepubertal boys - are emerging. Cryopreservation of testicular tissue samples for the preservation of fertility - although still an experimental method at present - is appealing in this context. In our opinion, testicular biopsy...

  10. Elaboration of Stable and Antibody Functionalized Positively Charged Colloids by Polyelectrolyte Complexation between Chitosan and Hyaluronic Acid

    Directory of Open Access Journals (Sweden)

    Ramona C. Polexe

    2013-07-01

    Full Text Available In this study, we describe the elaboration of multifunctional positively charged polyelectrolyte complex (PEC nanoparticles, designed to be stable at physiological salt concentration and pH, for effective targeted delivery. These nanoparticles were obtained by charge neutralization between chitosan (CS as polycation and hyaluronic acid (HA as polyanion. We showed that the course of the complexation process and the physico-chemical properties of the resulting colloids were impacted by (i internal parameters such as the Degree of Acetylation (DA, i.e., the molar ration of acetyl glucosamine residues and molar mass of CS, the HA molar mass and (ii external parameters like the charge mixing ratio and the polymer concentrations. As a result, nonstoichiometric colloidal PECs were obtained in water or PBS (pH 7.4 and remained stable over one month. The polymer interactions were characterized by thermal analysis (DSC and TGA and the morphology was studied by scanning electron microscopy. A model antibody, anti-ovalbumine (OVA immunoglobulin A (IgA was sorbed on the particle surface in water and PBS quantitatively in 4 h. The CS-HA/IgA nanoparticles average size was between 425–665 nm with a positive zeta potential. These results pointed out that CS-HA can be effective carriers for use in targeted drug delivery.

  11. One year of high-intensity interval training improves exercise capacity, but not left ventricular function in stable heart transplant recipients: a randomised controlled trial.

    Science.gov (United States)

    Rustad, Lene A; Nytrøen, Kari; Amundsen, Brage H; Gullestad, Lars; Aakhus, Svend

    2014-02-01

    Heart transplant recipients have lower exercise capacity and impaired cardiac function compared with the normal population. High-intensity interval training (HIIT) improves exercise capacity and cardiac function in patients with heart failure and hypertension, but the effect on cardiac function in stable heart transplant recipients is not known. Thus, we investigated whether HIIT improved cardiac function and exercise capacity in stable heart transplant recipients by use of comprehensive rest- and exercise-echocardiography and cardiopulmonary exercise testing. Fifty-two clinically stable heart transplant recipients were randomised either to HIIT (4 × 4 minutes at 85-95% of peak heart rate three times per week for eight weeks) or to control. Three such eight-week periods were distributed throughout one year. Echocardiography (rest and submaximal exercise) and cardiopulmonary exercise testing were performed at baseline and follow-up. One year of HIIT increased VO 2peak from 27.7 ± 5.5 at baseline to 30.9 ± 5.0 ml/kg/min at follow-up, while the control group remained unchanged (28.5 ± 7.0 vs. 28.0 ± 6.7 ml/kg per min, p HIIT. Whereas HIIT is feasible in heart transplant recipients and effectively improves exercise capacity, it does not alter cardiac systolic and diastolic function significantly. Thus, the observed augmentation in exercise capacity is best explained by extra-cardiac adaptive mechanisms.

  12. Unpredictably Stable

    DEFF Research Database (Denmark)

    Failla, Virgilio; Melillo, Francesca; Reichstein, Toke

    2014-01-01

    Is entrepreneurship a more stable career choice for high employment turnover individuals? We find that a transition to entrepreneurship induces a shift towards stayer behavior and identify job matching, job satisfaction and lock-in effects as main drivers. These findings have major implications...

  13. IFNy+ and IFNy- Treg subsets with stable and unstable Foxp3 expression in kidney transplant recipients with good long-term graft function.

    Science.gov (United States)

    Trojan, Karina; Unterrainer, Christian; Aly, Mostafa; Zhu, Li; Weimer, Rolf; Bulut, Nuray; Morath, Christian; Opelz, Gerhard; Daniel, Volker

    2016-10-29

    Treg are a heterogenous cell population. In the present study we attempted to identify Treg subsets that might contribute to stable and good long-term graft function. Lymphocyte and Treg subsets were studied in 136 kidney transplant recipients with good long-term graft function and in 52 healthy control individuals using eight-color-fluorescence flow cytometry. Foxp3 TSDR methylation status was investigated in enriched IFNy+ and IFNy- Treg preparations using high resolution melt analysis. Compared with healthy controls, patients showed strong associations of IFNy secreting Helios+ and Helios- Treg with Treg that co-expressed perforin and/or CTLA4 (CD152; pterm graft function possess IFNy+ and IFNy- Treg with stable and unstable Foxp3 expression in the blood. They co-express CD28, HLADR, CTLA4, CXCR3, Lselectin, TGFβ, perforin and FasL and might contribute to the establishment and maintenance of good long-term graft function. Copyright © 2016. Published by Elsevier B.V.

  14. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  15. Survival after stereotactic biopsy of malignant gliomas

    International Nuclear Information System (INIS)

    Coffey, R.J.; Lunsford, L.D.; Taylor, F.H.

    1988-01-01

    For many patients with malignant gliomas in inaccessible or functionally important locations, stereotactic biopsy followed by radiation therapy (RT) may be a more appropriate initial treatment than craniotomy and tumor resection. We studied the long term survival in 91 consecutive patients with malignant gliomas diagnosed by stereotactic biopsy: 64 had glioblastoma multiforme (GBM) and 27 had anaplastic astrocytoma (AA). Sixty-four per cent of the GBMs and 33% of the AAs involved deep or midline cerebral structures. The treatment prescribed after biopsy, the tumor location, the histological findings, and the patient's age at presentation (for AAs) were statistically important factors determining patient survival. If adequate RT (tumor dose of 5000 to 6000 cGy) was not prescribed, the median survival was less than or equal to 11 weeks regardless of tumor histology or location. The median survival for patients with deep or midline tumors who completed RT was similar in AA (19.4 weeks) and GBM (27 weeks) cases. Histology was an important predictor of survival only for patients with adequately treated lobar tumors. The median survival in lobar GBM patients who completed RT was 46.9 weeks, and that in lobar AA patients who completed RT was 129 weeks. Cytoreductive surgery had no statistically significant effect on survival. Among the clinical factors examined, age of less than 40 years at presentation was associated with prolonged survival only in AA patients. Constellations of clinical features, tumor location, histological diagnosis, and treatment prescribed were related to survival time

  16. Stable particles

    International Nuclear Information System (INIS)

    Samios, N.P.

    1993-01-01

    I have been asked to review the subject of stable particles, essentially the particles that eventually comprised the meson and baryon octets. with a few more additions -- with an emphasis on the contributions made by experiments utilizing the bubble chamber technique. In this activity, much work had been done by the photographic emulsion technique and cloud chambers-exposed to cosmic rays as well as accelerator based beams. In fact, many if not most of the stable particles were found by these latter two techniques, however, the forte of the bubble chamber (coupled with the newer and more powerful accelerators) was to verify, and reinforce with large statistics, the existence of these states, to find some of the more difficult ones, mainly neutrals and further to elucidate their properties, i.e., spin, parity, lifetimes, decay parameters, etc

  17. Distinct requirements for signal peptidase processing and function in the stable signal peptide subunit of the Junin virus envelope glycoprotein

    International Nuclear Information System (INIS)

    York, Joanne; Nunberg, Jack H.

    2007-01-01

    The arenavirus envelope glycoprotein (GP-C) retains a cleaved and stable signal peptide (SSP) as an essential subunit of the mature complex. This 58-amino-acid residue peptide serves as a signal sequence and is additionally required to enable transit of the assembled GP-C complex to the Golgi, and for pH-dependent membrane fusion activity. We have investigated the C-terminal region of the Junin virus SSP to study the role of the cellular signal peptidase (SPase) in generating SSP. Site-directed mutagenesis at the cleavage site (positions - 1 and - 3) reveals a pattern of side-chain preferences consistent with those of SPase. Although position - 2 is degenerate for SPase cleavage, this residue in the arenavirus SSP is invariably a cysteine. In the Junin virus, this cysteine is not involved in disulfide bonding. We show that replacement with alanine or serine is tolerated for SPase cleavage but prevents the mutant SSP from associating with GP-C and enabling transport to the cell surface. Conversely, an arginine mutation at position - 1 that prevents SPase cleavage is fully compatible with GP-C-mediated membrane fusion activity when the mutant SSP is provided in trans. These results point to distinct roles of SSP sequences in SPase cleavage and GP-C biogenesis. Further studies of the unique structural organization of the GP-C complex will be important in identifying novel opportunities for antiviral intervention against arenaviral hemorrhagic disease

  18. Tissue Biopsies in Diabetes Research

    DEFF Research Database (Denmark)

    Højlund, Kurt; Gaster, Michael; Beck-Nielsen, Henning

    2007-01-01

    resistance of glucose disposal and glycogen synthesis in this tissue are hallmark features of type 2 diabetes in humans (2,3). During the past two decades, we have carried out more than 1200 needle biopsies of skeletal muscle to study the cellular mechanisms underlying insulin resistance in type 2 diabetes....... Together with morphological studies, measurement of energy stores and metabolites, enzyme activity and phosphorylation, gene and protein expression in skeletal muscle biopsies have revealed a variety of cellular abnormalities in patients with type 2 diabetes and prediabetes. The possibility to establish...... and gene expression profiling on skeletal muscle biopsies have pointed to abnormalities in mitochondrial oxidative phosphorylation in type 2 diabetes. These novel insights will inevitably cause a renewed interest in studying skeletal muscle. This chapter reviews our experience to date and gives a thorough...

  19. A functional form-stable phase change composite with high efficiency electro-to-thermal energy conversion

    International Nuclear Information System (INIS)

    Wu, Wenhao; Huang, Xinyu; Li, Kai; Yao, Ruimin; Chen, Renjie; Zou, Ruqiang

    2017-01-01

    Graphical abstract: The thermal conductivity of PU was enhanced to 43 times of the pristine value by encapsulation in a PGF, PU@PGF can be used for highly efficient electro-to-heat energy conversion and storage with the highest energy storage efficiency up to 85%. - Highlights: • The composite exhibits an in-situ solid-solid phase change behavior. • The enthalpy of polyurethane is enhanced within the matrix. • The thermal conductivity of the composite is 43 times as much as that of the polyurethane. • Supercooling of polyurethane is greatly reduced. • The composite is applied to cold protection as a wear layer. - Abstract: A novel solid-to-solid phase change composite brick was prepared by combination of polyurethane (PU) and pitch-based graphite foam (PGF). The carbonaceous support, which can be used for mass production, not only greatly improves the thermal conductivity but promote electro-to-heat conversion efficiency of organic phase change materials (PCMs). Our composite retained the enthalpy of PCM and exhibited a greatly reduced supercooling temperature. The novel composite was investigated by differential scanning calorimetry (DSC), thermogravimetric analysis (TGA) and scanning electron microscope (SEM). The enthalpy of polyurethane has increased about 8.6% after infiltrating into graphite foam. The composite was very stable during thermal cycle test, and the electro-to-heat conversion efficiency achieves to 85% at lower voltages (1.5–1.8 V), which can vastly reduce energy consumption. The as-prepared composite was used in a wear layer to test its performance comparing with normal fabric.

  20. Follow-up Sonography after Sonoguided Renal Biopsy

    International Nuclear Information System (INIS)

    Kim, Hyung Soo; Park, Cheol Min; Cha, In Ho

    1996-01-01

    To assess ultrasonographic findings and clinical significance after renal biopsy. 174 cases of post-biopsy sonography were studied retrospectively. We classified post-biopsy hematoma on the basis of their size as small (thickness less than 1 cm, length less than 3cm), medium (thickness less than 1cm, length greater than 3 cm), large (thickness greater than 1 cm, length greater than 3 cm). We also compared bleeding parameters (prothrombin time, partial thromboplastin time) and renal function in both cases which had hematoma or not. Total 33 hematomas were found (19%). Small hematoma was observed in 14 cases, medium hematoma in 16 cases, large hematoma in 3 cases. Severe complications requiring prompt therapy occurred in 1 case(0.6%). In 6 cases hematocrit fell by more than 4%, all of these hematomas were observed on US. Severe complications after sonoguided renal biopsy were rare. There was poor correlation between prebiopsybleeding parameter, renal function and post-biopsy hematomas. And sonography is considered as adequate method for follow up of post-biopsy hematoma

  1. Systemic vascular function, measured with forearm flow mediated dilatation, in acute and stable cerebrovascular disease: a case-control study

    Directory of Open Access Journals (Sweden)

    Blacker David

    2010-10-01

    Full Text Available Abstract Background Acute ischaemic stroke is associated with alteration in systemic markers of vascular function. We measured forearm vascular function (using forearm flow mediated dilatation to clarify whether recent acute ischaemic stroke/TIA is associated with impaired systemic vascular function. Methods Prospective case control study enrolling 17 patients with recent acute ischaemic stroke/TIA and 17 sex matched controls with stroke more than two years previously. Forearm vascular function was measured using flow medicated dilatation (FMD. Results Flow mediated dilatation was 6.0 ± 1.1% in acute stroke/TIA patients and 4.7 ± 1.0% among control subjects (p = 0.18. The mean paired difference in FMD between subjects with recent acute stroke and controls was 1.25% (95% CI -0.65, 3.14; p = 0.18. Endothelium independent dilatation was measured in six pairs of participants and was similar in acute stroke/TIA patients (22.6 ± 4.3% and control subjects (19.1 ± 2.6%; p = 0.43. Conclusions Despite the small size of this study, these data indicate that recent acute stroke is not necessarily associated with a clinically important reduction in FMD.

  2. Structure and functioning of intertidal food webs along an avian flyway: a omparative approach using stable isotopes

    NARCIS (Netherlands)

    Catry, T.; Lourenco, P.M.; Lopes, R.J.; Carneiro, C.; Alves, J.A.; Costa, J.; Rguibi-Idrissi, H.; Bearhop, S.; Piersma, T.; Granadeiro, J.P.

    2016-01-01

    Food webs and trophic dynamics of coastal systems have been the focus of intense research throughout the world, as they prove to be critical in understanding ecosystem processes and functions. However, very few studies have undertaken a quantitative comparison of entire food webs from a key consumer

  3. The future perspectives in transrectal prostate ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Sung Il Hwang

    2014-12-01

    Full Text Available Prostate cancer is one of the most common neoplasms in men. Transrectal ultrasound (TRUS-guided systematic biopsy has a crucial role in the diagnosis of prostate cancer. However, it shows limited value with gray-scale ultrasound alone because only a small number of malignancies are visible on TRUS. Recently, new emerging technologies in TRUS-guided prostate biopsy were introduced and showed high potential in the diagnosis of prostate cancer. High echogenicity of ultrasound contrast agent reflect the increased status of angiogenesis in tumor. Molecular imaging for targeting specific biomarker can be also used using ultrasound contrast agent for detecting angiogenesis or surface biomarker of prostate cancer. The combination of TRUS-guided prostate biopsy and ultrasound contrast agents can increase the accuracy of prostate cancer diagnosis. Elastography is an emerging ultrasound technique that can provide the information regarding tissue elasticity and stiffness. Tumors are usually stiffer than the surrounding soft tissue. In two types of elastography techniques, shearwave elastography has many potential in that it can provide quantitative information on tissue elasticity. Multiparametric magnetic resonance imaging (MRI from high resolution morphologic and functional magnetic resonance (MR technique enables to detect more prostate cancers. The combination of functional techniques including apparent diffusion coefficient map from diffusion weighted imaging, dynamic contrast enhanced MR and MR spectroscopy are helpful in the localization of the prostate cancer. MR-ultrasound (US fusion image can enhance the advantages of both two modalities. With MR-US fusion image, targeted biopsy of suspicious areas on MRI is possible and fusion image guided biopsy can provide improved detection rate. In conclusion, with recent advances in multiparametric-MRI, and introduction of new US techniques such as contrast-enhanced US and elastography, TRUS-guided biopsy

  4. Cost-effectiveness of anatomical and functional test strategies for stable chest pain: public health perspective from a middle-income country.

    Science.gov (United States)

    Bertoldi, Eduardo G; Stella, Steffen F; Rohde, Luis Eduardo P; Polanczyk, Carisi A

    2017-05-04

    The aim of this research is to evaluate the relative cost-effectiveness of functional and anatomical strategies for diagnosing stable coronary artery disease (CAD), using exercise (Ex)-ECG, stress echocardiogram (ECHO), single-photon emission CT (SPECT), coronary CT angiography (CTA) or stress cardiacmagnetic resonance (C-MRI). Decision-analytical model, comparing strategies of sequential tests for evaluating patients with possible stable angina in low, intermediate and high pretest probability of CAD, from the perspective of a developing nation's public healthcare system. Hypothetical cohort of patients with pretest probability of CAD between 20% and 70%. The primary outcome is cost per correct diagnosis of CAD. Proportion of false-positive or false-negative tests and number of unnecessary tests performed were also evaluated. Strategies using Ex-ECG as initial test were the least costly alternatives but generated more frequent false-positive initial tests and false-negative final diagnosis. Strategies based on CTA or ECHO as initial test were the most attractive and resulted in similar cost-effectiveness ratios (I$ 286 and I$ 305 per correct diagnosis, respectively). A strategy based on C-MRI was highly effective for diagnosing stable CAD, but its high cost resulted in unfavourable incremental cost-effectiveness (ICER) in moderate-risk and high-risk scenarios. Non-invasive strategies based on SPECT have been dominated. An anatomical diagnostic strategy based on CTA is a cost-effective option for CAD diagnosis. Functional strategies performed equally well when based on ECHO. C-MRI yielded acceptable ICER only at low pretest probability, and SPECT was not cost-effective in our analysis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. The effect of adjuvant N-acetylcysteine effervescent tablets therapy on cardiopulmonary function and airway remodeling in patients with stable COPD

    Directory of Open Access Journals (Sweden)

    Gui-Fang Hu1

    2017-05-01

    Full Text Available Objective: To study the effect of adjuvant N-acetylcysteine (NAC effervescent tablets therapy on cardiopulmonary function and airway remodeling in patients with stable chronic obstructive pulmonary disease (COPD. Methods: Patients with stable COPD treated in Zigong Third People’s Hospital and West China Hospital, Sichuan University between May 2014 and October 2016 were selected and randomly divided into two groups, NAC group received N-acetylcysteine effervescent tablets combined with routine treatment, and control group received routine treatment. Before treatment as well as 2 weeks and 4 weeks after treatment, oxidative stress indexes and airway remodeling indexes in serum as well as inflammatory response indexes in peripheral blood were determined. Results: MDA, PC, 8-OHdG, MMP2, MMP3 and MMP9 contents in serum as well as NLRP3, ASC, p38MAPK and TREM-1 mRNA expression levels in peripheral blood mononuclear cells of both groups of patients after treatment were significantly lower than those before treatment while TAC levels as well as TIMP1 and TIMP2 contents in serum were significantly higher than those before treatment, and MDA, PC, 8-OHdG, MMP2, MMP3 and MMP9 contents in serum a well as NLRP3, ASC, p38MAPK and TREM-1 mRNA expression levels in peripheral blood mononuclear cells of NAC group after treatment were significantly lower than those of control group while TAC levels as well as TIMP1 and TIMP2 contents in serum were significantly higher than those of control group. Conclusion: Adjuvant NAC effervescent tablets treatment of stable COPD can improve the effect of oxidative stress and inflammatory response on cardiopulmonary function, and inhibit the airway remodeling caused by protease activation.

  6. Stable isotopes

    International Nuclear Information System (INIS)

    Brazier, J.L.; Guinamant, J.L.

    1995-01-01

    According to the progress which has been realised in the technology of separating and measuring isotopes, the stable isotopes are used as preferable 'labelling elements' for big number of applications. The isotopic composition of natural products shows significant variations as a result of different reasons like the climate, the seasons, or their geographic origins. So, it was proved that the same product has a different isotopic composition of alimentary and agriculture products. It is also important in detecting the pharmacological and medical chemicals. This review article deals with the technology, like chromatography and spectrophotometry, adapted to this aim, and some important applications. 17 refs. 6 figs

  7. Stable Tetraquarks

    Energy Technology Data Exchange (ETDEWEB)

    Quigg, Chris [Fermilab

    2018-04-13

    For very heavy quarks, relations derived from heavy-quark symmetry imply novel narrow doubly heavy tetraquark states containing two heavy quarks and two light antiquarks. We predict that double-beauty states will be stable against strong decays, whereas the double-charm states and mixed beauty+charm states will dissociate into pairs of heavy-light mesons. Observing a new double-beauty state through its weak decays would establish the existence of tetraquarks and illuminate the role of heavy color-antitriplet diquarks as hadron constituents.

  8. Thionyl chloride assisted functionalization of amorphous carbon nanotubes: A better field emitter and stable nanofluid with better thermal conductivity

    Energy Technology Data Exchange (ETDEWEB)

    Sarkar, S.K.; Jha, A. [School of Materials Science and Nanotechnology, Jadavpur University, Kolkata 700 032 (India); Chattopadhyay, K.K., E-mail: kalyan_chattopadhyay@yahoo.com [Thin Film & Nanoscience Laboratory, Department of Physics, Jadavpur University, Kolkata 700 032 (India); School of Materials Science and Nanotechnology, Jadavpur University, Kolkata 700 032 (India)

    2015-06-15

    Highlights: • Thionyl chloride assisted functionalization of amorphous carbon nanotubes (a-CNTs). • Improved dispersion enhanced thermal conductivity of engine oil. • Again f-a-CNTs showed enhanced field emission property compared to pure a-CNTs. - Abstract: Amorphous carbon nanotubes (a-CNTs) were synthesized at low temperature in open atmosphere and further functionalized by treating them in thionyl chloride added stearic acid-dichloro methane solution. The as prepared functionalized a-CNTs (f-a-CNTs) were characterized by Raman spectroscopy, Fourier transformed infrared spectroscopy, X-ray photoelectron spectroscopy, transmission and scanning electron microscopy. The nanofluid was prepared by dispersing f-a-CNTs in engine oil using ultrasonic treatment. The effective thermal conductivity of as prepared nanofluid was investigated at different loading (volume fraction of f-a-CNTs). Obtained experimental data of thermal conductivity were compared with the predicted values, calculated using existing theoretical models. Stability of the nanofluid was tested by means of zeta potential measurement to optimize the loading. The as prepared f-a-CNTs sample also showed improved field emission result as compared to pristine a-CNTs. Dependence of field emission behavior on inter electrode distance was investigated too.

  9. Highly stable pyridinium-functionalized cross-linked anion exchange membranes for all vanadium redox flow batteries

    Science.gov (United States)

    Zeng, L.; Zhao, T. S.; Wei, L.; Zeng, Y. K.; Zhang, Z. H.

    2016-11-01

    It has recently been demonstrated that the use of anion exchange membranes (AEMs) in vanadium redox flow batteries (VRFBs) can reduce the migration of vanadium ions through the membrane due to the Donnan exclusion effect among the positively charged functional groups and vanadium ions. However, AEMs are plagued by low chemical stability in harsh chemical environments. Here we propose and fabricate a pyridinium-functionalized cross-linked AEM for VRFBs. The pyridinium-functionalized bromomethylated poly (2,6-dimethyl-1,4-phenylene oxide) exhibits a superior chemical stability as a result of the strengthened internal cross-linking networks and the chemical inertness of the polymer backbone. Therefore, the membrane exhibits littler decay in a harsh environment for 20 days during the course of an ex situ immersion test. A cycling test also demonstrates that the VRFB assembled with the membrane enable to retain 80% of the initial discharge capacity over 537 cycles with a capacity decay rate of 0.037% cycle-1. Meanwhile, the membrane also shows a low vanadium permeability and a reasonably high conductivity in supporting electrolytes. Hence, all the measurements and performance tests reported in this work suggest that the membrane is a promising AEM for redox flow batteries to achieve excellent cycling stability and superior cell performance.

  10. Combining functional weed ecology and crop stable isotope ratios to identify cultivation intensity: a comparison of cereal production regimes in Haute Provence, France and Asturias, Spain.

    Science.gov (United States)

    Bogaard, Amy; Hodgson, John; Nitsch, Erika; Jones, Glynis; Styring, Amy; Diffey, Charlotte; Pouncett, John; Herbig, Christoph; Charles, Michael; Ertuğ, Füsun; Tugay, Osman; Filipovic, Dragana; Fraser, Rebecca

    This investigation combines two independent methods of identifying crop growing conditions and husbandry practices-functional weed ecology and crop stable carbon and nitrogen isotope analysis-in order to assess their potential for inferring the intensity of past cereal production systems using archaeobotanical assemblages. Present-day organic cereal farming in Haute Provence, France features crop varieties adapted to low-nutrient soils managed through crop rotation, with little to no manuring. Weed quadrat survey of 60 crop field transects in this region revealed that floristic variation primarily reflects geographical differences. Functional ecological weed data clearly distinguish the Provence fields from those surveyed in a previous study of intensively managed spelt wheat in Asturias, north-western Spain: as expected, weed ecological data reflect higher soil fertility and disturbance in Asturias. Similarly, crop stable nitrogen isotope values distinguish between intensive manuring in Asturias and long-term cultivation with minimal manuring in Haute Provence. The new model of cereal cultivation intensity based on weed ecology and crop isotope values in Haute Provence and Asturias was tested through application to two other present-day regimes, successfully identifying a high-intensity regime in the Sighisoara region, Romania, and low-intensity production in Kastamonu, Turkey. Application of this new model to Neolithic archaeobotanical assemblages in central Europe suggests that early farming tended to be intensive, and likely incorporated manuring, but also exhibited considerable variation, providing a finer grained understanding of cultivation intensity than previously available.

  11. Effect of liraglutide, a glucagon-like peptide-1 analogue, on left ventricular function in stable chronic heart failure patients with and without diabetes (LIVE)

    DEFF Research Database (Denmark)

    Jorsal, Anders; Kistorp, Caroline Micheala Nervil; Holmager, Pernille

    2017-01-01

    trial. Patients (n = 241) with reduced left ventricular ejection fraction (LVEF ≤45%) were recruited (February 2012 to August 2015). Patients were clinically stable and on optimal heart failure treatment. Intervention was liraglutide 1.8 mg once daily or matching placebo for 24 weeks. The LVEF...... with and without diabetes. Treatment with liraglutide was associated with an increase in heart rate and more serious cardiac adverse events, and this raises some concern with respect to the use of liraglutide in patients with chronic heart failure and reduced left ventricular function. More data on the safety......AIMS: To determine the effect of the glucagon-like peptide-1 analogue liraglutide on left ventricular function in chronic heart failure patients with and without type 2 diabetes. METHODS AND RESULTS: LIVE was an investigator-initiated, randomised, double-blinded, placebo-controlled multicentre...

  12. Biopsy techniques for intraocular tumors

    Directory of Open Access Journals (Sweden)

    Pukhraj Rishi

    2016-01-01

    Full Text Available Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88-95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous, suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies.

  13. Gastric tissue biopsy and culture

    Science.gov (United States)

    ... symptoms may include: Loss of appetite or weight loss Nausea and vomiting Pain in the upper part of the belly Black stools Vomiting blood or coffee ground-like material A gastric tissue biopsy and culture can help detect: Cancer Infections, most commonly Helicobacter ...

  14. Stable beams

    CERN Multimedia

    2015-01-01

    Stable beams: two simple words that carry so much meaning at CERN. When LHC page one switched from "squeeze" to "stable beams" at 10.40 a.m. on Wednesday, 3 June, it triggered scenes of jubilation in control rooms around the CERN sites, as the LHC experiments started to record physics data for the first time in 27 months. This is what CERN is here for, and it’s great to be back in business after such a long period of preparation for the next stage in the LHC adventure.   I’ve said it before, but I’ll say it again. This was a great achievement, and testimony to the hard and dedicated work of so many people in the global CERN community. I could start to list the teams that have contributed, but that would be a mistake. Instead, I’d simply like to say that an achievement as impressive as running the LHC – a machine of superlatives in every respect – takes the combined effort and enthusiasm of everyone ...

  15. The Role of Biopsy in Pediatric Dermatopathology

    Directory of Open Access Journals (Sweden)

    Fatma Şule Afşa

    2011-09-01

    Full Text Available Background and Design: Pediatric dermatology is characterized by skin disorders which have frequencies different from those in adults. Skin biopsies are necessary for differential diagnosis and clinicopathologic correlation is very important. The aim of this study was to evaluate retrospectively the pediatric dermatology cases in whom biopsy was performed for differential diagnosis and to investigate the contribution of biopsy to diagnosis of skin disorders. Material and Methods: The cases from whom biopsy was taken in the pediatric dermatology clinic during a three-year period were evaluated retrospectively for pre-diagnoses, biopsy diagnoses, and success of biopsies.Results: Two hundred thirteen (1.7% skin biopsies had been taken from a total of 12420 patients. Henoch-Schönlein purpura, psoriasis, pityriasis lichenoides, pityriasis rosea, lichen planus, pityriasis rubra pilaris, erythema multiforme, atopic dermatitis, granuloma annulare, and pigmented purpuric dermatosis were the most frequent skin disorders diagnosed dermatopathologically. In a total of 120 (56.3% cases, the biopsy diagnosis was within the pre-diagnosis and a biopsy consistency was present. In 25 (11.7% cases, biopsy had no contribution to the differential diagnosis. An absolutely different diagnosis which was incompatible with the pre-diagnosis had been reported in 10 (4.6% cases. Conclusion: In pediatric dermatology, skin biopsy is very helpful for the differential diagnosis. An easy biopsy procedure for the patient, an effective designation of biopsy indication, a good dermatopathologic correlation and an experienced team of pediatric dermatopathology increase the success of skin biopsies.

  16. Respiratory analysis of coupled mitochondria in cryopreserved liver biopsies

    Directory of Open Access Journals (Sweden)

    Mercedes García-Roche

    2018-07-01

    Full Text Available The aim of this work was to develop a cryopreservation method of small liver biopsies for in situ mitochondrial function assessment. Herein we describe a detailed protocol for tissue collection, cryopreservation, high-resolution respirometry using complex I and II substrates, calculation and interpretation of respiratory parameters. Liver biopsies from cow and rat were sequentially frozen in a medium containing dimethylsulfoxide as cryoprotectant and stored for up to 3 months at −80 °C. Oxygen consumption rate studies of fresh and cryopreserved samples revealed that most respiratory parameters remained unchanged. Additionally, outer mitochondrial membrane integrity was assessed adding cytochrome c, proving that our cryopreservation method does not harm mitochondrial structure. In sum, we present a reliable way to cryopreserve small liver biopsies without affecting mitochondrial function. Our protocol will enable the transport and storage of samples, extending and facilitating mitochondrial function analysis of liver biopsies. Keywords: Cryopreservation, Mitochondria, Biopsy, Oxygen consumption rate, High-resolution respirometry, Mitochondrial function

  17. Retroperitoneoscopic renal biopsy in children

    Directory of Open Access Journals (Sweden)

    Carlos M. Jesus

    2007-08-01

    Full Text Available OBJECTIVE: We present our experience in a series of 17 consecutive pediatric patients submitted to retroperitoneal laparoscopic renal biopsy. MATERIALS AND METHODS: Retroperitoneal laparoscopic renal biopsy (LRB was performed in 5 boys and 12 girls. Mean age was 8.1 years and age range from 2 to 12. Two or three trocars were used to expose the inferior pole of the kidney, remove enough cortical parenchymal specimen and fulgurate the biopsy site. Assessment included surgical time, estimated blood loss, hospitalization period, analgesia requirements, complications and number of glomeruli present in the specimen. RESULTS: LRB was successfully performed in all 15 patients (88%. In two cases, LRB was not possible to be performed. One patient was converted to a transperitoneal laparoscopy due to tear in the peritoneum. The other patient had had previous abdominal surgery and, during retroperitoneal balloon dilation, the peritoneum was opened and the open biopsy was performed. A third patient had postoperatively a perirenal hematoma, which was solved spontaneously. Complication rate was 17.6% (3/17 cases. Mean operative time was 65 minutes, while mean estimated blood loss was 52 mL, mean hospital stay was 2.2 days and mean analgesic requirement was 100 mg of tramadol. The mean number of glomeruli present in the specimen was 60. CONCLUSION: Retroperitoneal laparoscopic renal biopsy in children is a simple, safe. Bleeding is still the most common complication. However, direct vision usually allows a safe control of this drawback. In our institution, laparoscopic approach is the chosen procedure in pediatric patients older than one - year - old.

  18. T-regulatory cells in chronic rejection versus stable grafts.

    Science.gov (United States)

    Al-Wedaie, Fatima; Farid, Eman; Tabbara, Khaled; El-Agroudy, Amgad E; Al-Ghareeb, Sumaya M

    2015-04-01

    Studying regulatory T cells in kidney allograft acceptance versus chronic rejection may help in the understanding of more mechanisms of immune tolerance and, in the future, may enable clinicians to induce immune tolerance and decrease the use of immunosuppressive drugs. The aim of the current study was to evaluate regulatory T cells in kidney transplant patients with stable graft versus transplant with biopsy-proven chronic rejection. The 3 groups that were studied included: kidney transplanted patients with no rejection episodes (n = 43); transplanted patients with biopsy-proven renal rejection (n = 27); and healthy age-matched nontransplanted individuals as controls (n = 42).The percentage of regulatory T cells (CD4+CD25+Foxp3+) in blood was determined by flow cytometry. The regulatory T cell percentage was significantly lower in chronic rejection patients than control or stable graft groups. No significant difference was observed in regulatory T cell percentage between the stable graft and control groups. In the stable graft group, patients on rapamycin had a significantly higher regulatory T cell percentage than patients on cyclosporine. No effect of donor type, infection, or duration after transplant was observed on regulatory T cell percentage. The results of the current study are consistent with previous studies addressing the function of regulatory T cells in inducing immunotolerance after kidney transplant. Considering the established role of regulatory T cells in graft maintenance and our observation of high regulatory T cell percentage in patients receiving rapamycin than cyclosporine, we recommend including rapamycin when possible in immunosuppressive protocols. The findings from the current study on the chronic rejection group support ongoing research of having treatment with regulatory T cells, which may constitute a novel, efficient antirejection therapy in the future.

  19. Stable and solid pellets of functionalized multi-walled carbon nanotubes produced under high pressure and temperature

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Pâmela Andréa Mantey dos [Universidade Federal do Rio Grande do Sul, UFRGS, Programa de Pós-Graduação em Ciência dos Materiais (Brazil); Gallas, Marcia Russman [Universidade Federal do Rio Grande do Sul, UFRGS, Instituto de Física (Brazil); Radtke, Cláudio; Benvenutti, Edilson Valmir [Universidade Federal do Rio Grande do Sul, UFRGS, Instituto de Química (Brazil); Elias, Ana Laura [The Pennsylvania State University, Department of Physics and Center for 2-D and Layered Materials (United States); Rajukumar, Lakshmy Pulickal [The Pennsylvania State University, Department of Materials Science and Engineering (United States); Terrones, Humberto [Rensselaer Polytechnic Institute, Department of Physics, Applied Physics and Astronomy (United States); Endo, Morinobu [Shinshu University, Carbon Institute of Science and Technology (Japan); Terrones, Mauricio [The Pennsylvania State University, Department of Physics and Center for 2-D and Layered Materials (United States); Costa, Tania Maria Haas, E-mail: taniaha@iq.ufrgs.br, E-mail: taniahac@gmail.com [Universidade Federal do Rio Grande do Sul, UFRGS, Programa de Pós-Graduação em Ciência dos Materiais (Brazil)

    2015-06-15

    High pressure/temperature was applied on samples of pristine multi-walled carbon nanotubes (MWCNT), functionalized nanotubes (f-MWCNT), and nanotubes doped with nitrogen (CN{sub x}MWNT). Cylindrical compact pellets of f-MWCNT with diameters of about 6 mm were obtained under pressure of 4.0 GPa at room temperature and at 400 °C, using graphite as pressure transmitting medium. The best pellet samples were produced using nitric and sulfuric acids for the functionalization of MWCNT. The effect of high pressure/temperature on CNT was investigated by several spectroscopy and characterization techniques, such as Raman spectroscopy, X-ray powder diffraction, X-ray photoelectron spectroscopy, N{sub 2} adsorption/desorption isotherms, and transmission electron microscopy. It was found that MWCNT maintain their main features in the compacted pellets, such as integrity, original morphology, and structure, demonstrating that high-pressure/temperature compaction can indeed be used to fabricate novel CNT self-supported materials. Additionally, the specific surface area and porosity are unchanged, which is important when using bulk CNT in adsorption processes. Raman analysis of the G’-band showed a shift to lower wavenumbers when f-MWCNT were processed under high pressure, suggesting that CNT are under tensile stress.

  20. Role of integrin-linked kinase for functional capacity of endothelial progenitor cells in patients with stable coronary artery disease

    International Nuclear Information System (INIS)

    Werner, Christian; Boehm, Michael; Friedrich, Erik B.

    2008-01-01

    Number and function of endothelial progenitor cells (EPCs) are down-regulated in patients with coronary artery disease (CAD). Integrin-linked kinase (ILK) is a signal and adaptor protein that regulates survival of mature endothelial cells and vascular development. Here we show that EPC dysfunction in patients with CAD is paralleled by down-regulation of ILK while restoration of ILK expression rescues the migratory defect of CAD-EPCs. Human EPCs transduced with dominant-negative ILK (DN-ILK) display significantly reduced expression of CD34 + /VEGFR-2 + , DiI-Ac-LDL uptake, and Ulex europaeus lectin binding. Mechanistically, DN-ILK-transfected EPCs are characterized by decreased proliferation, while proliferation is increased in wild-type ILK-transfected EPCs. These effects are paralleled by changes in cyclin D1 expression, colony forming units, and cytoskeletal rearrangement. Functionally, ILK is necessary and sufficient for SDF-1-triggered migration and adhesion in EPCs. These data extend current knowledge about the role of ILK in EPC biology and implicate ILK as a therapeutic target in CAD.

  1. Impedance analysis of GPCR-mediated changes in endothelial barrier function: overview and fundamental considerations for stable and reproducible measurements.

    Science.gov (United States)

    Stolwijk, Judith A; Matrougui, Khalid; Renken, Christian W; Trebak, Mohamed

    2015-10-01

    The past 20 years has seen significant growth in using impedance-based assays to understand the molecular underpinning of endothelial and epithelial barrier function in response to physiological agonists and pharmacological and toxicological compounds. Most studies on barrier function use G protein-coupled receptor (GPCR) agonists which couple to fast and transient changes in barrier properties. The power of impedance-based techniques such as electric cell-substrate impedance sensing (ECIS) resides in its ability to detect minute changes in cell layer integrity label-free and in real-time ranging from seconds to days. We provide a comprehensive overview of the biophysical principles, applications, and recent developments in impedance-based methodologies. Despite extensive application of impedance analysis in endothelial barrier research, little attention has been paid to data analysis and critical experimental variables, which are both essential for signal stability and reproducibility. We describe the rationale behind common ECIS data presentation and interpretation and illustrate practical guidelines to improve signal intensity by adapting technical parameters such as electrode layout, monitoring frequency, or parameter (resistance versus impedance magnitude). Moreover, we discuss the impact of experimental parameters, including cell source, liquid handling, and agonist preparation on signal intensity and kinetics. Our discussions are supported by experimental data obtained from human microvascular endothelial cells challenged with three GPCR agonists, thrombin, histamine, and sphingosine-1-phosphate.

  2. Engineering Copper Carboxylate Functionalities on Water Stable Metal–Organic Frameworks for Enhancement of Ammonia Removal Capacities

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Jayraj N.; Garcia-Gutierrez, Erika Y.; Moran, Colton M.; Deneff, Jacob I.; Walton, Krista S.

    2017-02-02

    Functionalization of copper carboxylate groups on a series of UiO-66 metal organic framework (MOF) analogues and their corresponding impact on humid and dry ammonia adsorption behavior were studied. Relative locations of possible carboxylic acid binding sites for copper on the MOF analogues were varied on ligand and missing linker defect sites. Materials after copper incorporation exhibited increased water vapor and ammonia affinity during isothermal adsorption and breakthrough experiments, respectively. The introduction of copper markedly increased ammonia adsorption capacities for all adsorbents possessing carboxyl binding sites. In particular, the new MOF UiO-66-(COOCu)2 displayed the highest ammonia breakthrough capacities of 6.38 and 6.84 mmol g–1 under dry and humid conditions, respectively, while retaining crystallinity and porosity. Relative carboxylic acid site locations were also found to impact sorbent stability, as missing linker defect functionalized materials degraded under humid conditions after copper incorporation. Postsynthetic metal insertion provides a method for adding sites that are analogous to open metal sites while maintaining good structural stability.

  3. CT-guided biopsies and drainage

    International Nuclear Information System (INIS)

    Scheppers, I.; Wollschlaeger, D.

    2011-01-01

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [de

  4. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking.......To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  5. Microwave-assisted rapid extracellular synthesis of stable bio-functionalized silver nanoparticles from guava (Psidium guajava) leaf extract

    Energy Technology Data Exchange (ETDEWEB)

    Raghunandan, Deshpande [H.K.E.S' s College of Pharmacy (India); Mahesh, Bedre D. [Gulbarga University, Materials Chemistry Laboratory, Department of Material Science (India); Basavaraja, S. [Jawaharlal Nehru Centre for Advanced Scientific Research, Veeco-India Nanotechnology Laboratory (India); Balaji, S. D. [Gulbarga University, Materials Chemistry Laboratory, Department of Material Science (India); Manjunath, S. Y. [Sri Krupa, Institute of Pharmaceutical Science (India); Venkataraman, A., E-mail: raman_chem@rediffmail.com [Gulbarga University, Materials Chemistry Laboratory, Department of Material Science (India)

    2011-05-15

    Our research interest centers on microwave-assisted rapid extracellular synthesis of bio-functionalized silver nanoparticles of 26 {+-} 5 nm from guava (Psidium guajava) leaf extract with control over dimension and composition. The reaction occurs very rapidly as the formation of spherical nanoparticles almost completed within 90 s. The probable pathway of the biosynthesis is suggested. Appearance, crystalline nature, size and shape of nanoparticles are understood by UV-vis (UV-vis spectroscopy), FTIR (fourier transform infrared spectroscopy), XRD (X-ray diffraction), FESEM (field emission scanning electron microscopy) and TEM (transmission electron microscopy) techniques. Microwave-assisted route is selected for the synthesis of silver nanoparticles to carry out the reaction fast, suppress the enzymatic action and to keep the process environmentally clean and green.

  6. Microwave-assisted rapid extracellular synthesis of stable bio-functionalized silver nanoparticles from guava (Psidium guajava) leaf extract

    International Nuclear Information System (INIS)

    Raghunandan, Deshpande; Mahesh, Bedre D.; Basavaraja, S.; Balaji, S. D.; Manjunath, S. Y.; Venkataraman, A.

    2011-01-01

    Our research interest centers on microwave-assisted rapid extracellular synthesis of bio-functionalized silver nanoparticles of 26 ± 5 nm from guava (Psidium guajava) leaf extract with control over dimension and composition. The reaction occurs very rapidly as the formation of spherical nanoparticles almost completed within 90 s. The probable pathway of the biosynthesis is suggested. Appearance, crystalline nature, size and shape of nanoparticles are understood by UV–vis (UV–vis spectroscopy), FTIR (fourier transform infrared spectroscopy), XRD (X-ray diffraction), FESEM (field emission scanning electron microscopy) and TEM (transmission electron microscopy) techniques. Microwave-assisted route is selected for the synthesis of silver nanoparticles to carry out the reaction fast, suppress the enzymatic action and to keep the process environmentally clean and green.

  7. Using stable isotopes and functional wood anatomy to identify underlying mechanisms of drought tolerance in different provenances of lodgepole pine

    Science.gov (United States)

    Isaac-Renton, Miriam; Montwé, David; Hamann, Andreas; Spiecker, Heinrich; Cherubini, Paolo; Treydte, Kerstin

    2016-04-01

    Choosing drought-tolerant seed sources for reforestation may help adapt forests to climate change. By combining dendroecological growth analysis with a long-term provenance trial, we assessed growth and drought tolerance of different populations of a wide-ranging conifer, lodgepole pine (Pinus contorta). This experimental design simulated a climate warming scenario through southward seed transfer, and an exceptional drought also occurred in 2002. We felled over 500 trees, representing 23 seed sources, which were grown for 32 years at three warm, dry sites in southern British Columbia, Canada. Northern populations showed poor growth and drought tolerance. These seed sources therefore appear to be especially at risk under climate change. Before recommending assisted migration of southern seeds towards the north, however, it is important to understand the physiological mechanisms underlying these responses. We combine functional wood anatomy with a dual-isotope approach to evaluate these mechanisms to drought response.

  8. Microwave-assisted rapid extracellular synthesis of stable bio-functionalized silver nanoparticles from guava ( Psidium guajava) leaf extract

    Science.gov (United States)

    Raghunandan, Deshpande; Mahesh, Bedre D.; Basavaraja, S.; Balaji, S. D.; Manjunath, S. Y.; Venkataraman, A.

    2011-05-01

    Our research interest centers on microwave-assisted rapid extracellular synthesis of bio-functionalized silver nanoparticles of 26 ± 5 nm from guava ( Psidium guajava) leaf extract with control over dimension and composition. The reaction occurs very rapidly as the formation of spherical nanoparticles almost completed within 90 s. The probable pathway of the biosynthesis is suggested. Appearance, crystalline nature, size and shape of nanoparticles are understood by UV-vis (UV-vis spectroscopy), FTIR (fourier transform infrared spectroscopy), XRD (X-ray diffraction), FESEM (field emission scanning electron microscopy) and TEM (transmission electron microscopy) techniques. Microwave-assisted route is selected for the synthesis of silver nanoparticles to carry out the reaction fast, suppress the enzymatic action and to keep the process environmentally clean and green.

  9. Association between depression, pressure pain sensitivity, stress and autonomous nervous system function in stable ischemic heart disease

    DEFF Research Database (Denmark)

    Ballegaard, Søren; Bergmann, Natasha; Karpatschof, Benny

    2016-01-01

    Background: Depression and ischemic heart disease (IHD) are associated with persistent stress and autonomic nervous system (ANS) dysfunction. The former can be measured by pressure pain sensitivity (PPS) of the sternum, and the latter by the PPS and systolic blood pressure (SBP) response to a tilt...... table test (TTT). Beta-blocker treatment reduces the efferent beta-adrenergic ANS function, and thus, the physiological stress response. Objective: To test the effect of beta-blockers on changes in depression score in patients with IHD, as well as the influence on persistent stress and ANS dysfunction...... PPS score correlated in non-users, only (r = 0.69, p = 0.007). Reduction in resting PPS correlated with an increase in PPS and SBP response to TTT. Conclusions: Stress intervention in patients with IHD was anti-depres- sive in non-users, only. Similarly, the association between the reduction...

  10. Barbed micro-spikes for micro-scale biopsy

    Science.gov (United States)

    Byun, Sangwon; Lim, Jung-Min; Paik, Seung-Joon; Lee, Ahra; Koo, Kyo-in; Park, Sunkil; Park, Jaehong; Choi, Byoung-Doo; Seo, Jong Mo; Kim, Kyung-ah; Chung, Hum; Song, Si Young; Jeon, Doyoung; Cho, Dongil

    2005-06-01

    Single-crystal silicon planar micro-spikes with protruding barbs are developed for micro-scale biopsy and the feasibility of using the micro-spike as a micro-scale biopsy tool is evaluated for the first time. The fabrication process utilizes a deep silicon etch to define the micro-spike outline, resulting in protruding barbs of various shapes. Shanks of the fabricated micro-spikes are 3 mm long, 100 µm thick and 250 µm wide. Barbs protruding from micro-spike shanks facilitate the biopsy procedure by tearing off and retaining samples from target tissues. Micro-spikes with barbs successfully extracted tissue samples from the small intestines of the anesthetized pig, whereas micro-spikes without barbs failed to obtain a biopsy sample. Parylene coating can be applied to improve the biocompatibility of the micro-spike without deteriorating the biopsy function of the micro-spike. In addition, to show that the biopsy with the micro-spike can be applied to tissue analysis, samples obtained by micro-spikes were examined using immunofluorescent staining. Nuclei and F-actin of cells which are extracted by the micro-spike from a transwell were clearly visualized by immunofluorescent staining.

  11. Ocular Manifestations of Biopsy-Proven Pulmonary Sarcoidosis in Korea

    Directory of Open Access Journals (Sweden)

    Seung Yong Choi

    2018-01-01

    Full Text Available Purpose. To investigate the clinical features and ocular manifestations of biopsy-proven pulmonary sarcoidosis in Korea. Methods. 55 patients diagnosed with pulmonary sarcoidosis by bronchoscopic or excisional biopsy were included. By retrospective clinical chart review, we investigated features of uveitis, ocular and systemic treatments, visual acuity, angiotensin-converting enzyme level, chest radiography, and pulmonary function tests. Clinical features were analyzed by presence of uveitis, site of biopsy, and first manifested sign of sarcoidosis. Results. The group with uveitis (n=39 presented with higher systemic (71.8% and immunosuppressive treatment rates (35.9% than the group without uveitis (31.3%, 0%, resp. (P=0.007, P=0.005, resp.. There were no significant differences in clinical features, including systemic treatment rate, by type of biopsy. Of 39 patients with uveitis, the group with ocular manifestation as a first sign of sarcoidosis showed higher systemic and immunosuppressive treatment rates (88.9%, 55.6% compared to the group with pulmonary manifestation as a first sign (57.1%, 19.0% (P=0.037, P=0.018, resp.. Conclusions. In patients with biopsy-proven pulmonary sarcoidosis, the presence of ocular involvement and uveitis as a first sign could be significant factors associated with higher systemic treatment rate, especially with immunosuppressive agents. Biopsy site determined by location and size had no influence on clinical features.

  12. STATIC BALANCE MEASUREMENTS IN STABLE AND UNSTABLE CONDITIONS DO NOT DISCRIMINATE GROUPS OF YOUNG ADULTS ASSESSED BY THE FUNCTIONAL MOVEMENT SCREEN™ (FMS™).

    Science.gov (United States)

    Trindade, Matheus A; de Toledo, Aline Martins; Cardoso, Jefferson Rosa; Souza, Igor Eduardo; Dos Santos Mendes, Felipe Augusto; Santana, Luisiane A; Carregaro, Rodrigo Luiz

    2017-11-01

    The Functional Movement Screen™ (FMS™) has been the focus of recent research related to movement profiling and injury prediction. However, there is a paucity of studies examining the associations between physical performance tasks such as balance and the FMS™ screening system. The purpose of this study was to compare measures of static balance in stable and unstable conditions between different groups divided by FMS™ scores. A secondary purpose was to discern if balance indices discriminate the groups divided by FMS™ scores. Cross-sectional study. Fifty-seven physically active subjects (25 men and 32 women; mean age of 22.9 ± 3.1 yrs) participated. The outcome was unilateral stance balance indices, composed by: Anteroposterior Index; Medial-lateral Index, and Overall Balance Index in stable and unstable conditions, as provided by the Biodex balance platform. Subjects were dichotomized into two groups, according to a FMS™ cut-off score of 14: FMS1 (score > 14) and FMS2 (score ≤ 14). The independent Students t-test was used to verify differences in balance indices between FMS1 and FMS2 groups. A discriminant analysis was applied in order to identify which of the balance indices would adequately discriminate the FMS™ groups. Comparisons between FMS1 and FMS2 groups in the stable and unstable conditions demonstrated a higher unstable Anteroposterior index for FMS2 (p=0.017). No significant differences were found for other comparisons (p>0.05). The indices did not discriminate the FMS™ groups ( p  > 0.05). The balance indices adopted in this study were not useful as a parameter for identification and discrimination of healthy subjects assessed by the FMS™. 2c.

  13. Sixty-four slice spiral CT angiography does not predict the functional relevance of coronary artery stenoses in patients with stable angina

    International Nuclear Information System (INIS)

    Hacker, Marcus; Hack, Nicolas; Hahn, Klaus; Tiling, Reinhold; Jakobs, Tobias; Nikolaou, Konstantin; Becker, Christoph; Reiser, Maximilian; Ziegler, Franz von; Knez, Andreas; Koenig, Andreas; Klauss, Volker

    2007-01-01

    The aim of this study was to evaluate spiral multidetector computed tomography (MDCT) angiography using 64-slice technique in the detection of functionally relevant coronary artery stenoses (CAS). Thirty-eight patients (62±11 years, 28 men) with stable angina (26 with suspected and 12 with known coronary artery disease) were investigated using 64-slice MDCT angiography and gated myocardial perfusion SPECT (gated SPECT); a subgroup of 30 patients had additional invasive coronary angiography (ICA). Stenoses with luminal narrowing of ≥50% were defined as ''significant'' in MDCT angiography and ICA. MDCT angiography was compared with gated SPECT and the combination of gated SPECT plus ICA with respect to the detection of functionally relevant CAS. The sensitivity, specificity and negative and positive predictive values of MDCT angiography in detecting reversible perfusion defects on gated SPECT were 63%, 80%, 94% and 32%, respectively, in vessel-based analysis and 71%, 62%, 72% and 60%, respectively, in patient-based analysis. If only reversible perfusion defects on gated SPECT with CAS ≥50% on ICA were considered, the sensitivity, specificity and negative and positive predictive values were, respectively, 85%, 79%, 98% and 33% for vessel-based analysis and 85%, 59%, 83% and 61% for patient-based analysis. Sixty-four slice MDCT angiography failed to predict the functional relevance of CAS, but had a high negative predictive value in the exclusion of functionally relevant CAS in symptomatic patients. (orig.)

  14. Sixty-four slice spiral CT angiography does not predict the functional relevance of coronary artery stenoses in patients with stable angina

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, Marcus; Hack, Nicolas; Hahn, Klaus; Tiling, Reinhold [Ludwig-Maximilians-University, Department of Nuclear Medicine, Munich (Germany); Jakobs, Tobias; Nikolaou, Konstantin; Becker, Christoph; Reiser, Maximilian [Ludwig-Maximilians-University, Department of Clinical Radiology, Munich (Germany); Ziegler, Franz von; Knez, Andreas [Ludwig-Maximilians-University, Department of Cardiology, Klinikum Grosshadern, Munich (Germany); Koenig, Andreas; Klauss, Volker [Ludwig-Maximilians-University, Department of Cardiology, Medizinische Poliklinik-Innenstadt, Munich (Germany)

    2007-01-15

    The aim of this study was to evaluate spiral multidetector computed tomography (MDCT) angiography using 64-slice technique in the detection of functionally relevant coronary artery stenoses (CAS). Thirty-eight patients (62{+-}11 years, 28 men) with stable angina (26 with suspected and 12 with known coronary artery disease) were investigated using 64-slice MDCT angiography and gated myocardial perfusion SPECT (gated SPECT); a subgroup of 30 patients had additional invasive coronary angiography (ICA). Stenoses with luminal narrowing of {>=}50% were defined as ''significant'' in MDCT angiography and ICA. MDCT angiography was compared with gated SPECT and the combination of gated SPECT plus ICA with respect to the detection of functionally relevant CAS. The sensitivity, specificity and negative and positive predictive values of MDCT angiography in detecting reversible perfusion defects on gated SPECT were 63%, 80%, 94% and 32%, respectively, in vessel-based analysis and 71%, 62%, 72% and 60%, respectively, in patient-based analysis. If only reversible perfusion defects on gated SPECT with CAS {>=}50% on ICA were considered, the sensitivity, specificity and negative and positive predictive values were, respectively, 85%, 79%, 98% and 33% for vessel-based analysis and 85%, 59%, 83% and 61% for patient-based analysis. Sixty-four slice MDCT angiography failed to predict the functional relevance of CAS, but had a high negative predictive value in the exclusion of functionally relevant CAS in symptomatic patients. (orig.)

  15. Polymer-Derived Ceramic Functionalized MoS2 Composite Paper as a Stable Lithium-Ion Battery Electrode

    Science.gov (United States)

    David, L.; Bhandavat, R.; Barrera, U.; Singh, G.

    2015-04-01

    A facile process is demonstrated for the synthesis of layered SiCN-MoS2 structure via pyrolysis of polysilazane functionalized MoS2 flakes. The layered morphology and polymer to ceramic transformation on MoS2 surfaces was confirmed by use of electron microscopy and spectroscopic techniques. Tested as thick film electrode in a Li-ion battery half-cell, SiCN-MoS2 showed the classical three-stage reaction with improved cycling stability and capacity retention than neat MoS2. Contribution of conversion reaction of Li/MoS2 system on overall capacity was marginally affected by the presence of SiCN while Li-irreversibility arising from electrolyte decomposition was greatly suppressed. This is understood as one of the reasons for decreased first cycle loss and increased capacity retention. SiCN-MoS2 in the form of self-supporting paper electrode (at 6 mg.cm-2) exhibited even better performance, regaining initial charge capacity of approximately 530 mAh.g-1 when the current density returned to 100 mA.g-1 after continuous cycling at 2400 mA.g-1 (192 mAh.g-1). MoS2 cycled electrode showed mud-cracks and film delamination whereas SiCN-MoS2 electrodes were intact and covered with a uniform solid electrolyte interphase coating. Taken together, our results suggest that molecular level interfacing with precursor-derived SiCN is an effective strategy for suppressing the metal-sulfide/electrolyte degradation reaction at low discharge potentials.

  16. Facile fabrication of a stable and recyclable lipase@amine-functionalized ZIF-8 nanoparticles for esters hydrolysis and transesterification

    Science.gov (United States)

    Cheong, Ling-Zhi; Wei, Yayu; Wang, Hongbin; Wang, Zhiying; Su, Xiurong; Shen, Cai

    2017-08-01

    Zeolitic imidazolate frameworks (ZIF) represent one of the metal organic frameworks (MOF) with high potential for enzyme immobilization due to their exceptional chemical and thermal stability, negligible cytotoxicity, and easy synthesis under mild biocompatible conditions. Amine-functionalized ZIF-8 (An-ZIF-8) are capable of forming multipoint attachment via hydrogen bonding with lipase which will immobilize and further enhance stabilization of lipase. In addition, increased hydrophilicity of An-ZIF-8 will increase partitioning of An-ZIF-8 immobilized lipase at the aqueous/organic interface which enable lipase to expose its active site and retain its catalytic activity at its highest. Present study reports the use of ZIF-8 and An-ZIF-8 nanoparticles as carrier for Burkholderia cepacia lipase (BCL), compares the ester hydrolysis and transesterification activities of immobilized lipase with those of free lipase, and evaluates the reusability and recovery rate of the immobilized lipase. An-ZIF-8 nanoparticles (average 130.42 ± 0.55 nm) were facilely synthesized via mixing ZIF-8 nanoparticles with ammonia hydroxide solution. Despite having similar characteristics of high crystallinity and forming cuboid-like particles, An-ZIF-8 demonstrated significantly ( P hydrolysis and transesterification activities with those of free BCL. BCL@An-ZIF-8 demonstrated superior catalytic stability in comparison to BCL@ZIF-8 with retainment of more than 80% of its initial hydrolysis and transesterification activity for at least 10 repeated runs. In addition, more than 80% of the BCL@An-ZIF-8 can be easily recovered during each cycle of the reusability test through simple centrifugation.

  17. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  18. Right Ventricular Pseudoaneurysm Following Endomyocardial Biopsy.

    Science.gov (United States)

    Pita; Santos; Manteiga; Rodriguez; Beiras

    1996-03-01

    Ventricular perforation is an unusual complication after endomyocardial biopsy in heart transplanted patients. We report a case of asymptomatic right ventricular perforation and pseudoaneurysm formation, secondary to endomyocardial biopsy, diagnosed by angiography. The spontaneous obliteration of the pseudoaneurysm was observed.

  19. Neuronavigator-guided cerebral biopsy.

    Science.gov (United States)

    Koivukangas, J; Louhisalmi, Y; Alakuijala, J; Oikarinen, J

    1993-01-01

    Neuronavigators are new dynamic interactive instruments that use on-line computers to orient imaging data to the surgical field and guide the neurosurgeon to his target. We have been working since 1987 on a neuronavigator that serves not only as a precise pointer, but also as a dynamic arm that can be used to hold instruments, such as biopsy guides. The neuronavigator arm consists of six joints with optical encoders and is attached to the Mayfield headholder. The arm is connected to a workstation running customized 3D image graphics software. Special instruments and surgical technique have been developed. Here, we report on early clinical experience with ten biopsy procedures: 4 low-grade and 3 high-grade astrocytomas, one craniopharyngioma and one chronic intracerebral haematoma and intracerebral cyst, both of the latter with surrounding tumour suspect tissue. In all glioma cases serial biopsies were taken from optimal sites under ultrasound imaging control. Eight cases showed representative tumour tissue, while in two cases neoplasia was ruled out. The neuronavigator proved to be versatile, allowing comprehensive imaging data to be adapted to the surgical field.

  20. Stable right ventricular size and function during short-term follow-up in patients with pulmonary regurgitation after tetralogy of Fallot repair

    International Nuclear Information System (INIS)

    Śpiewak, M.; Małek, Ł.A.; Petryka, J.; Biernacka, E.K.; Hoffman, P.; Demkow, M.; Miśko, J.; Rużyłło, W.

    2013-01-01

    Aim: To assess changes in ventricular size and function over time in conservatively treated adult patients with repaired tetralogy of Fallot (TOF) and significant pulmonary regurgitation (PR). Materials and methods: Patients with repaired TOF who had undergone more than one cardiac magnetic resonance study were identified. To confine the cause of ventricular size and function deviation to PR, patients with residual ventricular septal defect, more than mild regurgitation at a valve other than the pulmonary valve, and known coronary artery disease were excluded. Results: The final analysis included 27 adults with PR fraction >20%. During a follow-up of mean 2.1 ± 0.8 years, there was no change in right ventricular (RV) end-diastolic volume (EDV; 162.1 ± 27.6 versus 164 ± 29.6 ml/m 2 , p = 0.5). Left ventricular (LV) EDV showed a small decrease (85.1 ± 16.2 versus 81.5 ± 14.1 ml/m 2 , p = 0.02). The mean PR fraction, PR volume, and peak RV outflow tract gradient did not change. Additionally, both RV ejection fraction (EF) and LVEF remained stable over the follow-up period (48.1 ± 6.5 versus 48.4 ± 6.7%, p = 0.83, and 57.3 ± 5.4 versus 57.2 ± 5.1 %, p = 0.91, respectively). Only two asymptomatic patients (7.4% of the study group) developed symptoms and the remaining did not deteriorate. Conclusion: The RVEDV, RVEF, and LVEF remained stable over a mean follow-up of approximately 2 years in the majority of adult patients after TOF repair with significant PR and a wide range of RVEDV

  1. Motor function declines over time in human immunodeficiency virus and is associated with cerebrovascular disease, while HIV-associated neurocognitive disorder remains stable.

    Science.gov (United States)

    M Elicer, Isabel; Byrd, Desiree; Clark, Uraina S; Morgello, Susan; Robinson-Papp, Jessica

    2018-04-25

    HIV-associated neurocognitive disorders (HAND) remain prevalent in the combined antiretroviral therapy (CART) era, especially the milder forms. Despite these milder phenotypes, we have shown that motor abnormalities persist and have quantified them with the HIV Dementia Motor Scale (HDMS). Our objectives were to replicate, in an independent sample, our prior findings that the HDMS is associated with cognitive impairment in HIV, while adding consideration of age-associated comorbidities such as cerebrovascular disease, and to examine the longitudinal trajectories of cognitive and motor dysfunction. We included all participants enrolled in the Manhattan HIV Brain Bank (MHBB) from January 2007 to May 2017 who had complete baseline data (N = 164). MHBB participants undergo standardized longitudinal assessments including documentation of comorbidities and medications, blood work, the HDMS, and neurocognitive testing. We found that motor dysfunction, cognitive impairment, and cerebrovascular disease were significantly associated with each other at baseline. Cerebrovascular disease independently predicted cognitive impairment in a multivariable model. Longitudinal analysis in a subset of 78 participants with ≥ 4 years of follow-up showed a stable cognition but declining motor function. We conclude that the HDMS is a valid measurement of motor dysfunction in HIV-infected patients and is associated with cognitive impairment and the presence of cerebrovascular disease. Cognitive impairment is mild and stable in CART-treated HIV; however, motor function declines over time, which may be related to the accrual of comorbidities such as cerebrovascular disease. Further research should examine the mechanisms underlying motor dysfunction in HIV and its clinical impact.

  2. Dose reduction of risperidone and olanzapine can improve cognitive function and negative symptoms in stable schizophrenic patients: A single-blinded, 52-week, randomized controlled study.

    Science.gov (United States)

    Zhou, Yanling; Li, Guannan; Li, Dan; Cui, Hongmei; Ning, Yuping

    2018-05-01

    The long-term effects of dose reduction of atypical antipsychotics on cognitive function and symptomatology in stable patients with schizophrenia remain unclear. We sought to determine the change in cognitive function and symptomatology after reducing risperidone or olanzapine dosage in stable schizophrenic patients. Seventy-five stabilized schizophrenic patients prescribed risperidone (≥4 mg/day) or olanzapine (≥10 mg/day) were randomly divided into a dose-reduction group ( n=37) and a maintenance group ( n=38). For the dose-reduction group, the dose of antipsychotics was reduced by 50%; for the maintenance group, the dose remained unchanged throughout the whole study. The Positive and Negative Syndrome Scale, Negative Symptom Assessment-16, Rating Scale for Extrapyramidal Side Effects, and Measurement and Treatment Research to Improve Cognition in Schizophrenia (MATRICS) Consensus Cognitive Battery were measured at baseline, 12, 28, and 52 weeks. Linear mixed models were performed to compare the Positive and Negative Syndrome Scale, Negative Symptom Assessment-16, Rating Scale for Extrapyramidal Side Effects and MATRICS Consensus Cognitive Battery scores between groups. The linear mixed model showed significant time by group interactions on the Positive and Negative Syndrome Scale negative symptoms, Negative Symptom Assessment-16, Rating Scale for Extrapyramidal Side Effects, speed of processing, attention/vigilance, working memory and total score of MATRICS Consensus Cognitive Battery (all pNegative Syndrome Scale negative subscale, Negative Symptom Assessment-16, Rating Scale for Extrapyramidal Side Effects, speed of processing, working memory and total score of MATRICS Consensus Cognitive Battery for the dose reduction group compared with those for the maintenance group (all pnegative symptoms in patients with stabilized schizophrenia.

  3. Freehand biopsy guided by electromagnetic needle tracking

    DEFF Research Database (Denmark)

    Ewertsen, C; Nielsen, Marie Kristina Rue; Nielsen, M Bachmann

    2011-01-01

    To evaluate the overall accuracy and time spent on biopsy guided by electromagnetic needle tracking in a phantom compared with the standard technique of US-guided biopsy with an attached steering device. Furthermore, to evaluate off-plane biopsy guided by needle tracking....

  4. 20 CFR 718.106 - Autopsy; biopsy.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Autopsy; biopsy. 718.106 Section 718.106... PNEUMOCONIOSIS Criteria for the Development of Medical Evidence § 718.106 Autopsy; biopsy. (a) A report of an autopsy or biopsy submitted in connection with a claim shall include a detailed gross macroscopic and...

  5. Stereotaxic core needle biopsy of breast microcalcifications obtained using a standard mammography table with an add-on unit

    International Nuclear Information System (INIS)

    Ward, S.E.; Taves, D.H.; McCurdy, L.I.

    2000-01-01

    To demonstrate the reliability of stereotaxic biopsy of indeterminate microcalcifications using a standard mammography table with an add-on unit. In 121 cases of indeterminate microcalcifications, core biopsy was performed using a standard mammography table with an add-on stereotaxic unit. Microcalcifications were identified on radiography of core specimens. Microcalcifications and a definitive histologic diagnosis were obtained in 112 core biopsies (92.6%), with no significant complications. In 23 lesions frank malignancy was diagnosed, and all of these diagnoses were confirmed on surgery. Pathologic examination suggested carcinoma in 4 lesions, and open biopsy confirmed malignancy in 3 of these cases. Four lesions showed atypical ductal hyperplasia. Benign disease was diagnosed in 81 lesions, of which 78 remained stable on mammographic follow-up (mean 16 months later) and 3 were subjected to surgical biopsy (of which 1 was malignant and 2 were benign). Nine cases were technically unsatisfactory because microcalcifications were not sampled. Stereotaxic core biopsy performed with an add-on unit is a safe and reliable technique for biopsy of indeterminate microcalcifications. For successful biopsy, microcalcifications must be harvested. Pathologic results should be correlated with mammographic findings. The accuracy rate compares favourably with results reported using prone biopsy tables. In an era of cost containment, this alternative to prone biopsy tables could result m significant savings in terms of capital investment and use of hospital rooms. In this study, surgical biopsy could have been avoided in 64.5% of cases. (author)

  6. Uses of stable isotopes

    International Nuclear Information System (INIS)

    Axente, Damian

    1998-01-01

    The most important fields of stable isotope use with examples are presented. These are: 1. Isotope dilution analysis: trace analysis, measurements of volumes and masses; 2. Stable isotopes as tracers: transport phenomena, environmental studies, agricultural research, authentication of products and objects, archaeometry, studies of reaction mechanisms, structure and function determination of complex biological entities, studies of metabolism, breath test for diagnostic; 3. Isotope equilibrium effects: measurement of equilibrium effects, investigation of equilibrium conditions, mechanism of drug action, study of natural processes, water cycle, temperature measurements; 4. Stable isotope for advanced nuclear reactors: uranium nitride with 15 N as nuclear fuel, 157 Gd for reactor control. In spite of some difficulties of stable isotope use, particularly related to the analytical techniques, which are slow and expensive, the number of papers reporting on this subject is steadily growing as well as the number of scientific meetings organized by International Isotope Section and IAEA, Gordon Conferences, and regional meeting in Germany, France, etc. Stable isotope application development on large scale is determined by improving their production technologies as well as those of labeled compound and the analytical techniques. (author)

  7. Stable long-term pulmonary function after fludarabine, antithymocyte globulin and i.v. BU for reduced-intensity conditioning allogeneic SCT.

    Science.gov (United States)

    Dirou, S; Malard, F; Chambellan, A; Chevallier, P; Germaud, P; Guillaume, T; Delaunay, J; Moreau, P; Delasalle, B; Lemarchand, P; Mohty, M

    2014-05-01

    Lung function decline is a well-recognized complication following allogeneic SCT (allo-SCT). Reduced-intensity conditioning (RIC) and in vivo T-cell depletion by administration of antithymocyte globulin (ATG) may have a protective role in the occurrence of late pulmonary complications. This retrospective study reported the evolution of lung function parameters within the first 2 years after allo-SCT in a population receiving the same RIC regimen that included fludarabine and i.v. BU in combination with low-dose ATG. The median follow-up was 35.2 months. With a median age of 59 years at the time of transplant, at 2 years, the cumulative incidences of non-relapse mortality was as low as 9.7%. The cumulative incidence of relapse was 33%. At 2 years, the cumulative incidences of extensive chronic GVHD (cGVHD) and of pulmonary cGVHD were 23.1% and 1.9%, respectively. The cumulative incidences of airflow obstruction and restrictive pattern were 3.8% and 9.6%, respectively. Moreover, forced expiratory volume (FEV1), forced vital capacity (FVC) and FEV1/FVC ratio remained stable from baseline up to 2 years post transplantation (P=0.26, P=0.27 and P=0.07, respectively). These results correspond favorably with the results obtained with other RIC regimens not incorporating ATG, and suggest that ATG may have a protective pulmonary role after allo-SCT.

  8. Pre-procedural peripheral endothelial function is associated with increased serum creatinine following percutaneous coronary procedure in stable patients with a preserved estimated glomerular filtration rate.

    Science.gov (United States)

    Sumida, Hitoshi; Matsuzawa, Yasushi; Sugiyama, Seigo; Sugamura, Koichi; Nozaki, Toshimitsu; Akiyama, Eiichi; Ohba, Keisuke; Konishi, Masaaki; Matsubara, Junichi; Fujisue, Koichiro; Maeda, Hirofumi; Kurokawa, Hirofumi; Iwashita, Satomi; Ogawa, Hisao; Tsujita, Kenichi

    2017-11-01

    Worsening renal function, indicated by increased serum creatinine (SCr), is a common complication of percutaneous coronary procedures. Risk factors for increased SCr overlap with coronary risk factors involved in endothelial dysfunction. We hypothesized that endothelial dysfunction, measured using the reactive hyperemia peripheral arterial tonometry index (RHI), can predict periprocedure-increased SCr. RHI was assessed before elective coronary procedures in 316 consecutive stable patients with a preserved estimated glomerular filtration rate (eGFR, >60mL/min/1.73m 2 ). SCr was measured before and 2 days after procedures. There was no significant correlation between natural logarithmic transformations of RHI (Ln-RHI) and basal Ln-eGFR. Periprocedure increase in SCr was observed in 148 (47%) patients. The increased SCr group had significantly lower Ln-RHI [0.48 (0.36, 0.62) vs. 0.59 (0.49, 0.76), pfunction by RHI is an effective strategy to assess the patient's risk conditions for worsening renal function after percutaneous coronary procedures. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  9. Comparison of sonoelastography guided biopsy with systematic biopsy: impact on prostate cancer detection

    International Nuclear Information System (INIS)

    Pallwein, Leo; Struve, Peter; Aigner, Friedrich; Gradl, Johann; Schurich, Matthias; Frauscher, Ferdinand; Mitterberger, Michael; Horninger, Wolfgang; Bartsch, Georg; Pedross, Florian

    2007-01-01

    A prospective study was performed to determine the value of sonoelastography (SE) targeted biopsy for prostate cancer (PCa) detection. A series of 230 male screening volunteers was examined. Two independent examiners evaluated each subject. One single investigator performed ≤5 SE targeted biopsies into suspicious regions in the peripheral zone only. The stiffness of the lesion was displayed by SE and color-coded from red (soft) to blue (hard). Hard lesions were considered as malignant and targeted by biopsy. Subsequently, another examiner performed ten systematic biopsies. Cancer detection rates of the two techniques were compared. Cancer was detected in 81 of the 230 patients (35%), including 68 (30%) by SE targeted biopsy and in 58 (25%) by systematic biopsy. Cancer was detected by targeted biopsy alone in 23 patients (10%) and by systematic biopsy alone in 13 patients (6%). The detection rate for SE targeted biopsy cores (12.7% or 135 of 1,109 cores) was significantly better than for systematic biopsy cores (5.6% or 130 of 2,300 cores, P < 0.001). SE targeted biopsy in a patient with cancer was 2.9-fold more likely to detect PCa than systematic biopsy. SE targeted biopsy detected more cases of PCa than systematic biopsy, with fewer than half the number of biopsy cores in this prostate-specific antigen screening population. (orig.)

  10. One-dimensional stable distributions

    CERN Document Server

    Zolotarev, V M

    1986-01-01

    This is the first book specifically devoted to a systematic exposition of the essential facts known about the properties of stable distributions. In addition to its main focus on the analytic properties of stable laws, the book also includes examples of the occurrence of stable distributions in applied problems and a chapter on the problem of statistical estimation of the parameters determining stable laws. A valuable feature of the book is the author's use of several formally different ways of expressing characteristic functions corresponding to these laws.

  11. Towards the mid-infrared optical biopsy

    DEFF Research Database (Denmark)

    Seddon, Angela B.; Benson, Trevor M.; Sujecki, Slawomir

    2016-01-01

    We are establishing a new paradigm in mid-infrared molecular sensing, mapping and imaging to open up the mid-infrared spectral region for in vivo (i.e. in person) medical diagnostics and surgery. Thus, we are working towards the mid-infrared optical biopsy ('opsy' look at, bio the biology) in situ...... in the body for real-time diagnosis. This new paradigm will be enabled through focused development of devices and systems which are robust, functionally designed, safe, compact and cost effective and are based on active and passive mid-infrared optical fibers. In particular, this will enable early diagnosis...... of a bright mid-infrared wideband source in a portable package as a first step for medical fiber-based systems operating in the mid-infrared. Moreover, mid-infrared molecular mapping and imaging is potentially a disruptive technology to give improved monitoring of the environment, energy efficiency, security...

  12. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using a flexible bronchoscopic biopsy forcep

    International Nuclear Information System (INIS)

    Kim, Jai Keun; Chung, Tae Sub; Kim, Dong Ik; Suh, Jung Ho

    1996-01-01

    Otolaryngoscopic biopsy of nasopharyngeal carcinoma is a generalized method which may be associated with inadequate sampling of tissue and patient discomfort. So, we tried fluoroscopy-guided transnasal biopsy using bronchoscopic biopsy forcep and evaluated its safety and efficacy. Prospectively we performed fluoroscopy-guided transnasal biopsy in 11 patients who were radiographically suspected of nasopharyngeal carcinoma. The posterior wall of the nasopharynx was coated with barium sulfate under fluoroscopy. A flexible bronchoscopic biopsy forcep with a steerable guiding catheter which was used in removal of intrahepatic duct stones was inserted through the nare. After localization of the tip of the biopsy forcep at tumor site with fluoroscopy, a tissue specimen was obtained. We also tried CT guided biopsy in initial 2cases. Each patient had otolaryngoscopic biopsy to compare the biopsy result and patient discomfort. We could have sufficient amount of tissue for pathological evaluation in 10 of 11 patients by the first pass with the fluoroscopic technique. Contrarily, otolaryngoscopic biopsy was successful in 7 of 11 patients on single passage. Additionally, 2 patients had complaint in our method comparing with 9 patients in otolaryngoscopic biopsy. Fluoroscopy-guided transnasal biopsy of nasopharyngeal carcinoma using the bronchoscopic biopsy forcep is safe and accurate. It can be a appropriate method competing otolaryngoscopic biopsy

  13. Ultrasound-guided renal biopsy: experience using an automated core biopsy system.

    Science.gov (United States)

    Chan, R; Common, A A; Marcuzzi, D

    2000-04-01

    To assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy using an automated core biopsy system, and to determine radiologists' accuracy in predicting sample adequacy. Ninety-five biopsies were performed on 25 native kidneys and 70 renal allografts using a 16-gauge automated, spring-loaded core biopsy device under real-time sonographic guidance. Radiologists performing the biopsy estimated the number of core samples needed to obtain an adequate specimen, based on visual inspection of each core. The final determination of the number of samples was made by a pathology technologist who attended each biopsy, based on preliminary microscopic examination of tissue cores. After each biopsy, an ultrasonographic examination was performed to search for biopsy-related hemorrhage, and a questionnaire was given to the patient to determine biopsy-related complications, which were categorized as either minor or major. The main indication for biopsy was acute renal failure (in 43.2% of biopsies). An average of 3 tissue cores per biopsy were obtained. Of the 94 patients in whom a biopsy was conducted to exclude diffuse renal disease, a mean of 12.5 glomeruli were present in each specimen. Overall, adequate tissue for diagnosis was obtained in 98.9% of cases. The radiologists' estimate of the number of core samples needed concurred with the pathology technologists' determination of sample adequacy in 88.4% of cases. A total of 26 complications occurred (in 27.4% of biopsies), consisting of 23 minor (24.2%) and 3 major (3.2%) complications. Real-time sonographic guidance in conjunction with an automated core biopsy system is a safe and accurate method of performing percutaneous renal biopsy. Routine use of sonographic examinations to search for biopsy-related complications is not indicated. Radiologists are accurate in estimating sample adequacy in most cases; however, the presence of a pathology technologist at the biopsy procedure virtually eliminates the

  14. 'Microerosions' in rectal biopsies in Crohn's disease

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1984-01-01

    Small (less than 1 mm), superficial erosions ('microerosions') have been observed stereo-microscopically in surface-stained rectal biopsies in Crohn's disease (CD). Biopsy specimens from 97 patients with CD, 225 with ulcerative colitis (UC), and a control material of 161 patients were investigated....... Granulomas were identified in 62% of the biopsies with microerosions and by examination of two consecutive biopsies from each of these patients, in 85% indicating a positive correlation. In patients with microerosions and a primary diagnosis of UC, granulomas were found in 38% and by examination of two...... biopsies in 54%. Patients with granulomas and a few other patients were reclassified as CD, but there still remained some patients with microerosions, who most probably had UC. In conclusion, microerosions are observed mainly in CD with colonic involvement. There is a high incidence of granulomas in biopsy...

  15. Nerve Biopsy In The Diagnosis Of Leporsy

    OpenAIRE

    Hazra B; Banerjee P P; Bhattacharyya N K; Gupta P N; Barbhunia J N; Sanyal S

    1997-01-01

    Skin and nerve biopsies were done in 33 cases of different clinical types of leprosy selected from Dermatology OPD of Medical College and Hospitals, Calcutta during 1994-95. Histopathological results were compared with emphasis on the role of nerve biopsies in detection of patients with multibacillary leprosy. The evident possibility of having patients with multibacillary leprosy in peripheral leprosy with multiple drugs. It is found that skin and nerve biopsy are equally informative in borde...

  16. Infective endocarditis with spondylodiscitis after prostate biopsy

    Directory of Open Access Journals (Sweden)

    Fernando Pivatto Júnior

    2014-04-01

    Full Text Available Transrectal ultrasonography-guided prostate needle biopsy is the ideal method to obtain prostate specimens for histological analysis and is therefore frequently used in clinical practice. In the majority of the studies, prostate biopsy is considered a safe procedure with few major complications. In the present report, we describe a case of endocarditis with spondylodiscitis, two very rare complications of prostate biopsy.

  17. Effect of a new functional CYP3A4 polymorphism on calcineurin inhibitors' dose requirements and trough blood levels in stable renal transplant patients.

    Science.gov (United States)

    Elens, Laure; van Schaik, Ron H; Panin, Nadtha; de Meyer, Martine; Wallemacq, Pierre; Lison, Dominique; Mourad, Michel; Haufroid, Vincent

    2011-10-01

    CYP3A4 is involved in the oxidative metabolism of many drugs and xenobiotics including the immunosuppressants tacrolimus (Tac) and cyclosporine (CsA). The objective of the study was to assess the potential influence of a new functional SNP in CYP3A4 on the pharmacokinetic parameters assessed by dose requirements and trough blood levels of both calcineurin inhibitors (CNI) in stable renal transplant patients. A total of 99 stable renal transplant patients receiving either Tac (n = 49) or CsA (n = 50) were genotyped for the CYP3A4 intron 6 C>T (rs35599367) and CYP3A5*3 SNPs. Trough blood levels ([Tac](0) or [CsA](0) in ng/ml), dose-adjusted [Tac](0) or [CsA](0) (ng/ml per mg/kg bodyweight) as well as doses (mg/kg bodyweight) required to achieve target concentrations were compared among patients according to allelic status for CYP3A4 and CYP3A5. Dose-adjusted concentrations were 2.0- and 1.6-fold higher in T-variant allele carriers for the CYP3A4 intron 6 C>T SNP compared with homozygous CC for Tac and CsA, respectively. When CYP3A4/CYP3A5 genotypes were combined, the difference was even more striking as the so-defined CYP3A poor metabolizer group presented dose-adjusted concentration 1.6- and 4.1-fold higher for Tac, and 1.5- and 2.2-fold higher for CsA than the intermediate metabolizer and extensive metabolizer groups, respectively. Multiple linear regression analysis revealed that, taken together, both CYP3A4 intron 6 and CYP3A5*3 SNPs explained more than 60 and 20% of the variability observed in dose-adjusted [Tac](0) and [CsA](0), respectively. The CYP3A4 intron 6 C>T polymorphism is associated with altered Tac and CsA metabolism. CYP3A4 intron 6 C>T along with CYP3A5*3 (especially for Tac) pharmacogenetic testing performed just before transplantation may help identifying patients at risk of CNI overexposure and contribute to limit CNI-related nephrotoxicity by refining the starting dose according to their genotype. Original submitted 5 May 2011; Revision

  18. Hypoxia marker labeling in tumor biopsies: quantification of labeling variation and criteria for biopsy sectioning

    International Nuclear Information System (INIS)

    Thrall, Donald E.; Rosner, Gary L.; Azuma, Chieko; McEntee, Margaret C.; Raleigh, James A.

    1997-01-01

    Background and purpose: The error associated with using biopsy-based methods for assessing parameters reflective of the tumor microenvironment depends on the variability in distribution of the parameter throughout the tumor and the biopsy sample. Some attention has been given to intratumoral distribution of parameters, but little attention has been given to their intrabiopsy distribution. We evaluated the intrabiopsy distribution of CCI-103F, a 2-nitroimidazole hypoxia marker. Materials and methods: The hypoxia marker CCI-103F was studied in dogs bearing spontaneous solid tumors. Two biopsies were taken from each of seven tumors, for a total of 14 biopsies. Biopsies were serially sectioned and four to six contiguous slides from each 100-150 μm of the biopsy were used to formulate the best estimate of CCI-103F labeled area throughout the biopsy sample. One, two or four slides were then randomly selected from each biopsy and the labeled area, based on this limited sample, was compared to the estimate obtained from counting all available slides. Random sampling of slides was repeated 1000 times for each biopsy sample. Results: CCI-103F labeling variance throughout the biopsy decreased as the estimated overall labeled area in the biopsy decreased. The error associated with estimating the overall labeled area in a biopsy from a randomly selected subset of slides decreased as the number of slides increased, and as the overall labeled area in the biopsy decreased. No minimally labeled biopsy was classified as unlabeled based on limited sampling. Conclusion: With regard to CCI-103F labeling, quantification of the labeled area in four randomly selected slides from a biopsy can provide, in most biopsies, an estimate of the labeled area in the biopsy within an absolute range of ±0.05

  19. When size matters: diagnostic value of kidney biopsy according to the gauge of the biopsy needle.

    Science.gov (United States)

    Roth, Rachel; Parikh, Samir; Makey, Dayanand; Foster, Jamison; Rozenblit, Grigory; Satoskar, Anjali; Nadasdy, Gyongyi; Von Visger, Jon; Hebert, Lee; Rovin, Brad H; Nadasdy, Tibor; Brodsky, Sergey V

    2013-01-01

    Kidney biopsy is a vital tool in the diagnosis of kidney disease. Although it has become a routine procedure, it is not complication-free. Some serious complications of percutaneous kidney biopsy include retroperitoneal hemorrhage and death. There is an increased belief that smaller biopsy needle size results in a lower complication rate. As renal pathologists, we witness an increased number of kidney biopsies performed with a small needle size (as low as gauge 22), which results in inadequate tissue sampling and often non-diagnostic biopsy results. Herein we report the diagnostic value of kidney biopsies according to the size of the biopsy needles. We performed kidney biopsies from nephrectomy specimens using biopsy needles of different sizes. Morphologic parameters were analyzed. We found that biopsies performed by small needles (gauges 20 and 22) contain significantly lower numbers of glomeruli and blood vessels, which limits pathologic evaluation. Data from our institution do not show differences in kidney biopsy complication rates between 16- and 18-gauge needles. Our data indicate that small biopsy needles do not provide sufficient material for diagnosis, and they increase the likelihood for a repeat biopsy. Copyright © 2013 S. Karger AG, Basel.

  20. Nerve Biopsy In The Diagnosis Of Leporsy

    Directory of Open Access Journals (Sweden)

    Hazra B

    1997-01-01

    Full Text Available Skin and nerve biopsies were done in 33 cases of different clinical types of leprosy selected from Dermatology OPD of Medical College and Hospitals, Calcutta during 1994-95. Histopathological results were compared with emphasis on the role of nerve biopsies in detection of patients with multibacillary leprosy. The evident possibility of having patients with multibacillary leprosy in peripheral leprosy with multiple drugs. It is found that skin and nerve biopsy are equally informative in borderline and lepromatour leprosy and is the only means to diagnose polyneuritic leprosy. Nerve biopsy appears to be more informative in the diagnosis of all clinical types of leprosy.

  1. Surface staining of small intestinal biopsies

    DEFF Research Database (Denmark)

    Poulsen, Steen Seier

    1977-01-01

    Small intestinal biopsies are most often by routine examined under a stereo-microscope, prior to embedding for histological examination. This is done in order to get a view of the appearance of the mucosal pattern, especially villus configuration. The distinctness of the surface pattern however......, is improved considerably if the biopsies are stained with Alcian Green and/or PAS before they are examined. In the present paper a detailed description is given of staining of small intestinal biopsies as whole mounts. The difference between the unstained and the stained biopsies is illustrated by a few...

  2. Robotic Prostate Biopsy in Closed MRI Scanner

    National Research Council Canada - National Science Library

    Fischer, Gregory

    2008-01-01

    .... This work enables prostate brachytherapy and biopsy procedures in standard high-field diagnostic MRI scanners through the development of a robotic needle placement device specifically designed...

  3. Needle muscle biopsy and its application

    Directory of Open Access Journals (Sweden)

    Meng-long CHEN

    2015-07-01

    Full Text Available Needle muscle biopsy is a straightforward and reliable minimally-invasive technique. During the past century, the needle biopsy can provide adequate samples and the technique has gradually gained wider acceptance. Compared with open biopsy, needle biopsy is less traumatic, with low rate of complications, and is suitable for the identifications and evaluations of muscular dystrophy, inflammatory myopathies and systemic diseases involving muscles, specially for infants and young children. Domestic insiders should be encouraged to apply this technique. DOI: 10.3969/j.issn.1672-6731.2015.06.003 

  4. Punch Biopsy Results in Misdiagnosis of Pilomatrixoma

    Directory of Open Access Journals (Sweden)

    Metin Temel

    2017-03-01

    Full Text Available Punch biopsy results in misdiagnosis of clinically unsuspected giant pilomatrixoma located over the parotid gland. This study presents a case of pilomatrixoma that was misdiagnosed as a malignant epithelial tumor using punch biopsy. A 25-year-old male was admitted to our clinic for the evaluation of a mass measuring 7×8×8 cm located over the parotid gland. The patient had previously undergone punch biopsy at another clinic because of a lesion in the parotid gland. Punch biopsy revealed a malignant epithelial tumor. The patient underwent excisional biopsy at our clinic. After the biopsy, the residual skin defect was treated using full-thickness skin grafts. The facial nerve and parotid gland were preserved during the biopsy. Histopathological examination of the excisional biopsy material revealed pilomatrixoma. Punch biopsy may result in misdiagnosis of skin lesions in the parotid gland. A differential diagnosis for benign tumors such as pilomatrixoma is essential prior to an aggressive surgical intervention of the parotid gland.

  5. Adult dementia: history, biopsy, pathology.

    Science.gov (United States)

    Torack, R M

    1979-05-01

    The historical events in the evolution of Alzheimer's disease are reviewed, including the initial description by Alois Alzheimer and the subsequent controversy regarding the nosological specificity of this entity. The similarity of senile dementia and Alzheimer's disease is emphasized. The basis for the modern concept of Alzheimer's disease as premature or accelerated aging is included in the review. The pathological correlates of the major categories of adult dementia have been described. The traditional criteria of neurofibrillary tangles and senile plaques have been re-evaluated using the current insight into these changes afforded by electron microscopy and biochemistry. The significance of amyloid has been described because it occurs within the senile plaque and also as the essential component of congophilic angiopathy. The new information regarding neuronal cell counts and the loss of choline acetyltransferase has been evaluated in terms of an indication of a pathogenic mechanism of Alzheimer's disease. The current understanding of normal pressure hydrocephalus, Creutzfeldt-Jakob disease, and multi-infarct dementia has been described. Brain biopsy in dementia has been described as having diagnostic, research, pathogenic, and prognostic value. The precautions involving the performance and handling of the biopsy have been stressed, particularly because these procedures involve conditions of possible slow virus etiology. The polemic for Alzheimer's disease as aging or slow virus infection has been summarized. At this time a consideration seems justified that Alzheimer's disease is an age-related, slow virus disease due to a hitherto unknown immune defect. Aging as an etiological agent must be clarified before Alzheimer's disease, in any form, can be considered to be an inevitable consequence of longevity.

  6. Biopsy Needle Localization and Tracking Using ROI-RK Method

    Directory of Open Access Journals (Sweden)

    Yue Zhao

    2014-01-01

    Full Text Available ROI-RK method is a biopsy needle localization and tracking method. Previous research work has proved that it has a robust performance on different series of simulated 3D US volumes. Unfortunately, in real situations, because of the strong speckle noise of the ultrasound image and the different echogenic properties of the tissues, the real 3D US volumes have more complex background than the simulated images used previously. In this paper, to adapt the ROI-RK method in real 3D US volumes, a line-filter enhancement calculation only in the ROI is added to increase the contrast between the needle and background tissue, decreasing the phenomenon of expansion of the biopsy needle due to reverberation of ultrasound in the needle. To make the ROI-RK method more stable, a self-correction system is also implemented. Real data have been acquired on an ex vivo heart of lamb. The result of the ROI-RK method shows that it is capable to localize and track the biopsy needle in real situations, and it satisfies the demand of real-time application.

  7. [Muscle biopsy in children: Usefulness in 2012].

    Science.gov (United States)

    Cuisset, J-M; Maurage, C-A; Carpentier, A; Briand, G; Thévenon, A; Rouaix, N; Vallée, L

    2013-01-01

    Muscle biopsy is a mainstay diagnostic tool for investigating neuromuscular disorders in children. We report the yield of pediatric muscle biopsy in a population of 415 children by a retrospective study of 419 biopsies performed between 1/01/2000 and 31/12/2009 in a neuropediatric department, including mitochondrial respiratory chain analysis for 87 children. Two hundred and fifty-five biopsies were from boys (61%) 164 from girls (39%). Their mean age at biopsy was 6.5years; 155 (37%) biopsies were obtained before the child was 5years old. Final histopathological diagnoses were: congenital myopathy (n=193, including 15 structural congenital myopathies); progressive muscular dystrophy (n=75 [18%] including 57 dystrophinopathies); congenital muscular dystrophy (n=17, including six primary merosinopathies); dermatomyositis (n=11); spinal muscular atrophy (n=9, including six atypical spinal muscular atrophies); metabolic myopathy (n=32, including 19 mitochondrial myopathies); encephalomyopathy (n=53 [13%], including 27 with a mitochondrial respiratory chain defect). Pathological diagnosis remained undetermined in 16 cases. In 184 patients (44%), the muscle biopsy revealed specific histopathological anomalies (dystrophic process; specific ultrastructural abnormalities; perifascicular atrophy; neurogenic atrophy; metabolic anomalies) enabling a precise etiological diagnosis. For 85% of progressive muscular dystrophies, the biopsy resulted in a genetic diagnosis after identification of the protein defect. In 15% of the congenital myopathies, histopathological anomalies focused attention on one or several genes. Concerning dystrophinopathies, quantification of dystrophin deficiency on the biopsy specimen contributed to the definition of the clinical phenotype: Duchenne, or Becker. In children with a myopathy, muscle biopsy is often indispensable to establish the etiological diagnosis. Based on the results from this series, muscle biopsy can provide a precise

  8. Outcomes of ultrasound guided renal mass biopsies.

    Science.gov (United States)

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  9. Transjugular Renal Biopsy: Our Experience and Technical Considerations

    International Nuclear Information System (INIS)

    See, Teik Choon; Thompson, Barbara C.; Howie, Alexander J.; Karamshi, M.; Papadopoulou, Anthie M.; Davies, Neil; Tibballs, Jonathan

    2008-01-01

    The purpose of this study was to describe the indications for and technique of transjugular renal biopsy (TJRB) and evaluate the efficacy and complications of this method. We performed a retrospective review of 59 patients who underwent TJRB using the Quick-core needle biopsy system (Cook, Letchworth, UK) over a 4-year period. The indications for obtaining renal biopsy included acute renal failure, chronic renal failure, nephrotic syndrome, and proteinuria with or without other associated disease. Indications for the transjugular approach included coagulopathy, biopsy of a solitary kidney or essentially single functioning kidney, simultaneous renal and hepatic biopsy, morbid obesity, and failed percutaneous biopsy. All but four cases were performed via the right internal jugular vein. The right, left, or both renal veins were cannulated in 41, 14, and 4 cases, respectively. Combined liver and renal biopsies were obtained in seven cases. Diagnostic biopsy specimens were obtained in 56 of 59 patients (95%). The number and size of tissue cores ranged from 1 to 9 mm and from 1 to 20 mm, respectively. The mean numbers of glomeruli per procedure on light microscopy and electron microscopy were 10.3 and 2.6, respectively. Specimens for immunohistology were acquired in 49 cases, of which 40 were adequate. Of the 56 successful TJRB procedures, 34 (61%) were associated with isolated capsular perforation (19), contained subcapsular leak (10), isolated collecting system puncture (1), and concurrent collecting system and capsular perforation (4). There was a significant increase in capsular perforation with six or more needle passes, although no significant correlation was seen between number of needle passes and complication. Six patients had minor complications defined as hematuria or loin pain. Seven patients developed major complications, of whom five received blood transfusion alone. Two required intervention: in one an arteriocalyceal fistula was embolized and the patient

  10. Photobiosynthesis of stable and functional silver/silver chloride nanoparticles with hydrolytic activity using hyperthermophilic β-glucosidases with industrial potential.

    Science.gov (United States)

    Araújo, Juscemácia N; Tofanello, Aryane; da Silva, Viviam M; Sato, Juliana A P; Squina, Fabio M; Nantes, Iseli L; Garcia, Wanius

    2017-09-01

    The β-glucosidases are important enzymes employed in a large number of processes and industrial applications, including biofuel production from biomass. Therefore, in this study, we reported for the first time the photobiosynthesis of stable and functional silver/silver chloride nanoparticles (Ag/AgCl-NPs) using two hyperthermostable bacterial β-glucosidases with industrial potential. The syntheses were straightforward and rapid processes carried out by mixing β-glucosidase and silver nitrate (in buffer 10mM Tris-HCl, pH 8) under irradiation with light (over a wavelength range of 450-600nm), therefore, compatible with the green chemistry procedure. Synthesized Ag/AgCl-NPs were characterized using a series of physical techniques. Absorption spectroscopy showed a strong absorption band centered at 460nm due to surface plasmon resonance of the Ag-NPs. X-ray diffraction analysis revealed that the Ag/AgCl-NPs were purely crystalline in nature. Under electron microscopy, Ag/AgCl-NPs of variable diameter ranging from 10 to 100nm can be visualized. Furthermore, electron microscopy, zeta potential and Fourier transform infrared spectroscopy results confirmed the presence of β-glucosidases coating and stabilizing the Ag/AgCl-NPs. Finally, the results showed that the enzymatic activities were maintained in the β-glucosidases assisted Ag/AgCl-NPs. The information described here should provide a useful basis for future studies of β-glucosidases assisted Ag/AgCl-NPs, including biotechnological applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Prostate biopsy after ano-rectal resection: value of CT-guided trans-gluteal biopsy

    International Nuclear Information System (INIS)

    Cantwell, Colin P.; Hahn, Peter F.; Gervais, Debra A.; Mueller, Peter R.

    2008-01-01

    We describe our single-institutional experience with computed tomography (CT)-guided percutaneous transgluteal biopsy of the prostate in patients in whom transrectal ultrasound-guided biopsy is precluded by prior ano-rectal resection. Between March 1995 and April 2007, 22 patients had 34 prostate biopsies (mean age 68; mean PSA 29 ng/ml; mean follow-up 6.1 years). The charts of patients who had transgluteal biopsy were reviewed for demographic, complications and pathology. Ninety-five percent (21/22) of primary biopsies were diagnostic. Of the 21 diagnostic biopsies, 11 were positive for prostate cancer and ten were definitive benign samples. Seventy-three percent (8/11) of the patients had progressive PSA elevation that mandated 11 further prostate biopsies. Six patients had a second biopsy, one patient had a third and one patient had a fourth biopsy. Among patients who had serial biopsies, 38% (3/8) had prostate cancer. No complications or death occurred. A malignant biopsy was not significantly associated with core number (P = 0.58) or a high PSA level (P 0.15). CT-guided transgluteal biopsy of the prostate is safe and effective. (orig.)

  12. Comparison between endobronchial forceps-biopsy and cryo-biopsy by flexible

    Directory of Open Access Journals (Sweden)

    Sami El-Dahdouh

    2016-01-01

    Conclusions: We concluded that cryoprobe biopsies were more successful than forceps biopsies in the diagnosis of lung cancer. Nevertheless, further investigations are warranted to determine an efficacy of cryoprobe biopsy procedures and a rationale to use as a part of routine flexible bronchoscopy.

  13. Ultrasound guided synovial biopsy of the wrist

    NARCIS (Netherlands)

    van Vugt, R. M.; van Dalen, A.; Bijlsma, J. W.

    1997-01-01

    Seven patients (4 female and 3 male, mean age 46) with arthritis of the wrist (n = 7) without known etiology were evaluated. High-definition ultrasound equipment was used for localization of synovial hypertrophy, suitable for ultrasound guided biopsy without risk. A 18-gauge diameter Tru-cut biopsy

  14. Stable Isotope Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Tissue samples (skin, bone, blood, muscle) are analyzed for stable carbon, stable nitrogen, and stable sulfur analysis. Many samples are used in their entirety for...

  15. Lysine-functionalized nanodiamonds as gene carriers: development of stable colloidal dispersion for in vitro cellular uptake studies and siRNA delivery application

    Science.gov (United States)

    Alwani, Saniya; Kaur, Randeep; Michel, Deborah; Chitanda, Jackson M; Verrall, Ronald E; Karunakaran, Chithra; Badea, Ildiko

    2016-01-01

    Purpose Nanodiamonds (NDs) are emerging as an attractive tool for gene therapeutics. To reach their full potential for biological application, NDs should maintain their colloidal stability in biological milieu. This study describes the behavior of lysine-functionalized ND (lys-ND) in various dispersion media, with an aim to limit aggregation and improve the colloidal stability of ND-gene complexes called diamoplexes. Furthermore, cellular and macromolecular interactions of lys-NDs are also analyzed in vitro to establish the understanding of ND-mediated gene transfer in cells. Methods lys-NDs were synthesized earlier through covalent conjugation of lysine amino acid to carboxylated NDs surface generated through re-oxidation in strong oxidizing acids. In this study, dispersions of lys-NDs were prepared in various media, and the degree of sedimentation was monitored for 72 hours. Particle size distributions and zeta potential measurements were performed for a period of 25 days to characterize the physicochemical stability of lys-NDs in the medium. The interaction profile of lys-NDs with fetal bovine serum showed formation of a protein corona, which was evaluated by size and charge distribution measurements. Uptake of lys-NDs in cervical cancer cells was analyzed by scanning transmission X-ray microscopy, flow cytometry, and confocal microscopy. Cellular uptake of diamoplexes (complex of lys-NDs with small interfering RNA) was also analyzed using flow cytometry. Results Aqueous dispersion of lys-NDs showed minimum sedimentation and remained stable over a period of 25 days. Size distributions showed good stability, remaining under 100 nm throughout the testing period. A positive zeta potential of >+20 mV indicated a preservation of surface charges. Size distribution and zeta potential changed for lys-NDs after incubation with blood serum, suggesting an interaction with biomolecules, mainly proteins, and a possible formation of a protein corona. Cellular internalization

  16. Lysine-functionalized nanodiamonds as gene carriers: development of stable colloidal dispersion for in vitro cellular uptake studies and siRNA delivery application.

    Science.gov (United States)

    Alwani, Saniya; Kaur, Randeep; Michel, Deborah; Chitanda, Jackson M; Verrall, Ronald E; Karunakaran, Chithra; Badea, Ildiko

    2016-01-01

    Nanodiamonds (NDs) are emerging as an attractive tool for gene therapeutics. To reach their full potential for biological application, NDs should maintain their colloidal stability in biological milieu. This study describes the behavior of lysine-functionalized ND (lys-ND) in various dispersion media, with an aim to limit aggregation and improve the colloidal stability of ND-gene complexes called diamoplexes. Furthermore, cellular and macromolecular interactions of lys-NDs are also analyzed in vitro to establish the understanding of ND-mediated gene transfer in cells. lys-NDs were synthesized earlier through covalent conjugation of lysine amino acid to carboxylated NDs surface generated through re-oxidation in strong oxidizing acids. In this study, dispersions of lys-NDs were prepared in various media, and the degree of sedimentation was monitored for 72 hours. Particle size distributions and zeta potential measurements were performed for a period of 25 days to characterize the physicochemical stability of lys-NDs in the medium. The interaction profile of lys-NDs with fetal bovine serum showed formation of a protein corona, which was evaluated by size and charge distribution measurements. Uptake of lys-NDs in cervical cancer cells was analyzed by scanning transmission X-ray microscopy, flow cytometry, and confocal microscopy. Cellular uptake of diamoplexes (complex of lys-NDs with small interfering RNA) was also analyzed using flow cytometry. Aqueous dispersion of lys-NDs showed minimum sedimentation and remained stable over a period of 25 days. Size distributions showed good stability, remaining under 100 nm throughout the testing period. A positive zeta potential of >+20 mV indicated a preservation of surface charges. Size distribution and zeta potential changed for lys-NDs after incubation with blood serum, suggesting an interaction with biomolecules, mainly proteins, and a possible formation of a protein corona. Cellular internalization of lys-NDs was confirmed

  17. Histopathologic quality of prostate core biopsy specimens: comparison of an MR-compatible biopsy needle and a ferromagnetic biopsy needle used for ultrasound-guided prostate biopsy

    International Nuclear Information System (INIS)

    Franiel, T.; Hamm, B.; Beyersdorff, D.; Fritzsche, F.; Staack, A.; Rost, J.

    2006-01-01

    Purpose: The histopathologic quality of core biopsy specimens obtained via MRI-guided prostate biopsy using a 16G MR-compatible needle was compared to that of biopsies obtained via ultrasound-guided biopsy using a conventional 18G stainless steel biopsy needle. Material and Methods: A retrospective analysis was performed for a total of 247 transrectal prostate biopsy specimens obtained from 32 patients. A total of 117 tissue cores were obtained from 15 patients (PSA of 10.8 ng/ml, age 64 years) who underwent an MRI-guided prostate biopsy using a 16G (1.7 mm) MR-compatible biopsy needle made of titanium alloy. The remaining 130 tissue cores were obtained from 17 patients (PSA of 6.7 ng/ml, age 68 years) who underwent a transrectal ultrasound-guided prostate biopsy using an 18G (1.3 mm) ferromagnetic stainless steel biopsy needle. The length and width of the histologic sections prepared from the tissue cores were measured to calculate the area. The histopathologic quality of the specimens was assessed microscopically using tissue fragmentation, the presence of crush artifacts, and the overall assessability as criteria. Each of these features was assigned a score from 0 to 3. All 3 features contributed equally to the overall score which ranged from 0 (no tissue) to 9 (optimal quality). Results: The overall quality scores assigned to the biopsies obtained with a 16G MR-compatible needle and an 18G ferromagnetic needle can be considered to be equivalent to a mean difference between patient related median scores of the specimens of -0.05 (95% confidence interval [-0.46; 0.36]) and a given equivalence limit of 1. The MRI biopsies showed more tissue fragmentation (p=0.001) but fewer crush artifacts (p=0.022) while the assessability did not differ significantly between the two needle types (p=0.064). There was also no significant difference in the calculated areas of the tissue cores (p=0.236). According to the different calibers of the biopsy needles, the lengths (p=0

  18. Coeliac disease: to biopsy or not?

    Science.gov (United States)

    Reilly, Norelle R; Husby, Steffen; Sanders, David S; Green, Peter H R

    2018-01-01

    Coeliac disease is increasingly recognized as a global problem in both children and adults. Traditionally, the findings of characteristic changes of villous atrophy and increased intraepithelial lymphocytosis identified in duodenal biopsy samples taken during upper gastrointestinal endoscopy have been required for diagnosis. Although biopsies remain advised as necessary for the diagnosis of coeliac disease in adults, European guidelines for children provide a biopsy-sparing diagnostic pathway. This approach has been enabled by the high specificity and sensitivity of serological testing. However, these guidelines are not universally accepted. In this Perspective, we discuss the pros and cons of a biopsy-avoiding pathway for the diagnosis of coeliac disease, especially in this current era of the call for more biopsies, even from the duodenal bulb, in the diagnosis of coeliac disease. In addition, a contrast between paediatric and adult guidelines is presented.

  19. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  20. Breast carcinoma in radiosurgery biopsy

    International Nuclear Information System (INIS)

    Cohen, Leonard O.; Brito, Pablo E.; Coppolecchia, German L.; Giarmana, Maria J.; Delle Ville, Rodolfo E.; Cortese, Eduardo M.

    2006-01-01

    Purpose: To report our experience on the detection of breast cancer (BC) through guided radiosurgical biopsies (GRSB) in the Gynecology Department of the Hospital Aeronautico Central (SGHAC). Materials and method: We retrospectively analyzed 622 GRSBs performed at the SGHAC between 1 January 1995 and 31 December 2004. We took into account single or associated lesions found in mammograms, which we subdivided into four types: 1) Non-palpable mammographic nodules; 2) Microcalcifications; 3) Structural distortions; 4) Mammographic asymmetries. Results: We found 332 non-palpable nodules (53.4%), 214 microcalcifications (34.4%), 40 structural distortions (6.4%), and 36 mammographic asymmetries (5.8%). Out of the 622 GRSBs performed during the above period, 152 BCs were diagnosed, that is, an incidence of 24.4% detected through this method. Out of the 152 BCs, 110 (72.4%) were invasive and 42 (27.6%) were noninvasive. Conclusions: Although 24.4% of BCs were identified through GRSBs, our tea m considers this to be the standard method for early detection of breast cancer. (author) [es

  1. Stable configurations in social networks

    Science.gov (United States)

    Bronski, Jared C.; DeVille, Lee; Ferguson, Timothy; Livesay, Michael

    2018-06-01

    We present and analyze a model of opinion formation on an arbitrary network whose dynamics comes from a global energy function. We study the global and local minimizers of this energy, which we call stable opinion configurations, and describe the global minimizers under certain assumptions on the friendship graph. We show a surprising result that the number of stable configurations is not necessarily monotone in the strength of connection in the social network, i.e. the model sometimes supports more stable configurations when the interpersonal connections are made stronger.

  2. Accuracy of Colposcopically Directed Biopsy: Results from an Online Quality Assurance Programme for Colposcopy in a Population-Based Cervical Screening Setting in Italy

    Science.gov (United States)

    Sideri, Mario; Garutti, Paola; Costa, Silvano; Cristiani, Paolo; Sassoli de Bianchi, Priscilla; Naldoni, Carlo

    2015-01-01

    Purpose. To report the accuracy of colposcopically directed biopsy in an internet-based colposcopy quality assurance programme in northern Italy. Methods. A web application was made accessible on the website of the regional Administration. Fifty-nine colposcopists out of the registered 65 logged in, viewed a posted set of 50 digital colpophotographs, classified them for colposcopic impression and need for biopsy, and indicated the most appropriate site for biopsy with a left-button mouse click on the image. Results. Total biopsy failure rate, comprising both nonbiopsy and incorrect selection of biopsy site, was 0.20 in CIN1, 0.11 in CIN2, 0.09 in CIN3, and 0.02 in carcinoma. Errors in the selection of biopsy site were stable between 0.08 and 0.09 in the three grades of CIN while decreasing to 0.01 in carcinoma. In multivariate analysis, the risk of incorrect selection of biopsy site was 1.97 for CIN2, 2.52 for CIN3, and 0.29 for carcinoma versus CIN1. Conclusions. Although total biopsy failure rate decreased regularly with increasing severity of histological diagnosis, the rate of incorrect selection of biopsy site was stable up to CIN3. In multivariate analysis, CIN2 and CIN3 had an independently increased risk of incorrect selection of biopsy site. PMID:26180805

  3. Pharmaceuticals labelled with stable isotopes

    International Nuclear Information System (INIS)

    Krumbiegel, P.

    1986-11-01

    The relatively new field of pharmaceuticals labelled with stable isotopes is reviewed. Scientific, juridical, and ethical questions are discussed concerning the application of these pharmaceuticals in human medicine. 13 C, 15 N, and 2 H are the stable isotopes mainly utilized in metabolic function tests. Methodical contributions are given to the application of 2 H, 13 C, and 15 N pharmaceuticals showing new aspects and different states of development in the field under discussion. (author)

  4. US-guided biopsy of renal allografts using 18G biopsy gun: analysis of 200 cases

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Lee, Jong Tae; Kim, Myeong Jin; Yoo, Hyung Sik; Kim, Ki Whang; Park, Ki Ill; Chung, Hyun Joo

    1995-01-01

    We evaluated the effectiveness and safety of 18G biopsy gun with US guidance in the transplanted kidneys. We performed 200 US-guided percutaneous biopsies using 18G biopsy gun. Diagnostic efficacy and complication of the biopsy in these patients were analyzed. Biopsy specimens were adequate for histologic diagnoses in 193 patients(96.5%). The mean of the biopsy frequency was 3, the mean of total glomerular number was 21.64 and the mean glomerular number per one biopsy was 6.93. Major complications occurred in 3 (1.5%) of the 200 biopsies; hematuria developed in two patients, AV fistula in one. These complications were successfully controlled either by only transfusion or by coil embolization. There were no statistical differences in blood pressure, hemoglobin, BUN/Cr between pre-and post-renal biopsies. US-guided percutaneous biopsy of renal allograft with 18G biopsy gun is simple, safe, and accurate method in evaluating the renal allograft dysfunction

  5. Improving CT-guided transthoracic biopsy of mediastinal lesions by diffusion-weighted magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Marcos Duarte; TyngI, Chiang Cheng; Bitencourt, Almir Galvao Vieira; Gross, Jefferson Luiz; Zurstrassen, Charles Edouard, E-mail: marcosduarte500@gmail.com [AC Camargo Cancer Center, Sao Paulo, SP (Brazil); Hochhegger, Bruno [Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), RS (Brazil). Dept. de Radiologia; Benveniste, Marcelo Felipe Kuperman; Odisio, Bruno Calazans [University of Texas, MD Anderson Cancer Center, Houston, TX (United States); Marchiori, Edson [Universidade Federal do Rio de Janeiro (UFRJ), Petropolis, RJ (Brazil)

    2014-11-15

    Objectives: to evaluate the preliminary results obtained using diffusion-weighted magnetic resonance imaging and the apparent diffusion coefficient for planning computed tomography-guided biopsies of selected mediastinal lesions. Methods: eight patients with mediastinal lesions suspicious for malignancy were referred for computed tomography-guided biopsy. Diffusion-weighted magnetic resonance imaging and apparent diffusion coefficient measurement were performed to assist in biopsy planning with diffusion/computed tomography fused images. We selected mediastinal lesions that could provide discordant diagnoses depending on the biopsy site, including large heterogeneous masses, lesions associated with lung atelectasis or consolidation, lesions involving large mediastinal vessels and lesions for which the results of biopsy using other methods and histopathological examination were divergent from the clinical and radiological suspicion. Results: in all cases, the biopsy needle was successfully directed to areas of higher signal intensity on diffusion weighted sequences and the lowest apparent diffusion coefficient within the lesion (mean, 0.8 [range, 0.6–1.1]610{sup -3} mm{sup 2}/s), suggesting high cellularity. All biopsies provided adequate material for specific histopathological diagnoses of four lymphomas, two sarcomas and two thymoma s. Conclusion: functional imaging tools, such as diffusion-weighted imaging and the apparent diffusion coefficient, are promising for implementation in noninvasive and imaging-guided procedures. However, additional studies are needed to confirm that mediastinal biopsy can be improved with these techniques. (author)

  6. Transvenous liver biopsy via the femoral vein

    International Nuclear Information System (INIS)

    Khosa, F.; McNulty, J.G.; Hickey, N.; O'Brien, P.; Tobin, A.; Noonan, N.; Ryan, B.; Keeling, P.W.N.; Kelleher, D.P.; McDonald, G.S.A.

    2003-01-01

    AIM: To study the safety, effectiveness and diagnostic value of transvenous forceps biopsy of the liver in 54 patients with coagulopathy, gross ascites or morbid obesity and suspected liver disease in whom percutaneous liver biopsy was contraindicated. MATERIAL AND METHODS: Forceps biopsy of the liver via the femoral vein was attempted in 54 adult patients with advanced liver disease of unknown aetiology who had coagulation disorders (41 cases), gross ascites (11 cases) or morbid obesity (two cases). In each patient two to six biopsies (average four) were taken using a radial jaw forceps inserted via the right or left femoral vein. RESULTS: The procedure was successful in 53 cases. Hepatic vein catheterization failed in one patient. Adequate liver tissue for diagnosis was obtained in 84% of cases. One patient developed delayed haemorrhage at 12 h from a capsular leak that was undetected during the biopsy procedure. This patient required blood transfusions and laparotomy to control bleeding. There were no deaths in the 53 patients studied. Transient minor chest and shoulder pain was encountered during sheath insertion into a hepatic vein in 23 patients. Three patients developed a femoral vein haematoma, which resolved with conservative treatment. CONCLUSION: Transvenous liver biopsy via the femoral vein is another safe, effective, simple alternative technique of biopsy when the percutaneous route is contraindicated

  7. Die Biopsie von Knochen- und Weichteiltumoren

    OpenAIRE

    Fuchs, B

    2008-01-01

    Technisch stellt die Biopsie von Knochen- und Weichteiltumoren einen simplen Akt dar, intellektuell aber ist die Planung einer Biopsie höchst anspruchsvoll. Zu häufig werden heutzutage immer noch Biopsien unsachgemäss durchgeführt, so dass die Behandlung - im besten Fall - erschwert wird. Eine unsachgemäss durchgeführte Biopsie führt häufig zu negativen funktionellen Konsequenzen für den Patienten, im schlimmsten Fall kann es die Prognose direkt beeinträchtigen. Aus diesem Grund soll...

  8. MRI follow-up after concordant, histologically benign diagnosis of breast lesions sampled by MRI-guided biopsy.

    Science.gov (United States)

    Li, Jie; Dershaw, D David; Lee, Carol H; Kaplan, Jennifer; Morris, Elizabeth A

    2009-09-01

    Follow-up MRI can be useful to confirm a benign diagnosis after MRI-guided breast biopsy. This retrospective study was undertaken to evaluate appropriate timing and imaging interpretation for the initial follow-up MRI when a benign, concordant histology is obtained using MRI-guided breast biopsy. Retrospective review was performed of 177 lesions visualized only by MRI in 172 women who underwent 9-gauge, vacuum-assisted core biopsy and marker placement with imaging-concordant benign histology. All underwent follow-up MRI within 12 months. Timing of the follow-up study, change in size, results of second biopsy if performed, and distance of localizing marker to the lesion on the follow-up study were recorded. At initial follow-up, 155 lesions were decreased or gone, 14 lesions were stable, and eight were enlarged. Seventeen (9.6%, 17/177) lesions underwent a second biopsy, including six enlarging, 10 stable, and one decreasing. Of these, four were malignant. Enlargement was seen in two carcinomas at 6 and 12 months. Two carcinomas, one stable at 2 months and another stable at 3 and 11 months, were rebiopsied because of suspicion of a missed lesion in the former and worrisome mammographic and sonographic changes in the latter. The distance of the marker from the lesion on follow-up did not correlate with biopsy accuracy. Follow-up MRI did not detect missed cancers because of lesion enlargement before 6 months after biopsy; two of four missed cancers were stable. The localizing marker can deploy away from the target despite successful sampling.

  9. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  10. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    Directory of Open Access Journals (Sweden)

    Adel S. Ahmed

    2016-04-01

    In conclusion: Thoracic ultrasound (TUS guided pleural biopsy had a diagnostic yield which was slightly lower but comparable to both CT guided pleural biopsy and medical thoracoscopic pleural biopsy (MT.

  11. Lysine-functionalized nanodiamonds as gene carriers: development of stable colloidal dispersion for in vitro cellular uptake studies and siRNA delivery application

    Directory of Open Access Journals (Sweden)

    Alwani S

    2016-02-01

    Full Text Available Saniya Alwani,1 Randeep Kaur,1 Deborah Michel,1 Jackson M Chitanda,2 Ronald E Verrall,3 Chithra Karunakaran,4 Ildiko Badea1 1Drug Design and Discovery Research Group, College of Pharmacy and Nutrition, 2Department of Chemical & Biological Engineering, 3Department of Chemistry, University of Saskatchewan, 4Canadian Light Source, Saskatoon, SK, Canada Purpose: Nanodiamonds (NDs are emerging as an attractive tool for gene therapeutics. To reach their full potential for biological application, NDs should maintain their colloidal stability in biological milieu. This study describes the behavior of lysine-functionalized ND (lys-ND in various dispersion media, with an aim to limit aggregation and improve the colloidal stability of ND-gene complexes called diamoplexes. Furthermore, cellular and macromolecular interactions of lys-NDs are also analyzed in vitro to establish the understanding of ND-mediated gene transfer in cells. Methods: lys-NDs were synthesized earlier through covalent conjugation of lysine amino acid to carboxylated NDs surface generated through re-oxidation in strong oxidizing acids. In this study, dispersions of lys-NDs were prepared in various media, and the degree of sedimentation was monitored for 72 hours. Particle size distributions and zeta potential measurements were performed for a period of 25 days to characterize the physicochemical stability of lys-NDs in the medium. The interaction profile of lys-NDs with fetal bovine serum showed formation of a protein corona, which was evaluated by size and charge distribution measurements. Uptake of lys-NDs in cervical cancer cells was analyzed by scanning transmission X-ray microscopy, flow cytometry, and confocal microscopy. Cellular uptake of diamoplexes (complex of lys-NDs with small interfering RNA was also analyzed using flow cytometry. Results: Aqueous dispersion of lys-NDs showed minimum sedimentation and remained stable over a period of 25 days. Size distributions showed

  12. Clinical application of Lin's biopsy grasper for intrauterine targeted biopsy and polypectomy during office hysteroscopy.

    Science.gov (United States)

    Cheng, Hsin-Yi; Lin, Bao-Liang; Tseng, Jen-Yu; Ueno, Kazunori; Nakada, Sakura

    2018-06-01

    Hysteroscopy has widely been used for diagnosis of the uterine cavity; however, target biopsy has often been difficult in part to the inherent limitations of ancillary instruments. Lin's biopsy grasper was specifically designed to work in conjunction with a flexible hysteroscope to obtain intrauterine biopsy under transabdominal sonography. Herein, we share our clinical experience in the management of endometrial abnormalities with the use of Lin's biopsy grasper during office-based hysteroscopy. From February 2006 to November 2016, the use of Lin's biopsy grasper for tissue biopsy was attempted on 126 cases. We retrospectively recorded and analyzed the patients' preoperative characteristics and biopsy outcomes to demonstrate the feasibility and efficacy of Lin's biopsy grasper. Out of the one hundred and twenty-six enrolled patients, satisfactory targeted biopsies were achieved; including high diagnostic rate (92.1%, with 116 cases confirmed histologically) and adequate tissue retrieval (77.8%, with 98 cases obtaining optimal specimen volume). All patients tolerated the procedure without analgesics or anesthesia. Diagnostic flexible hysteroscopy combined with the use of Lin's biopsy grasper has proven to be an effective tool for intrauterine evaluation and obtaining tissue sample. Copyright © 2018. Published by Elsevier B.V.

  13. Stable convergence and stable limit theorems

    CERN Document Server

    Häusler, Erich

    2015-01-01

    The authors present a concise but complete exposition of the mathematical theory of stable convergence and give various applications in different areas of probability theory and mathematical statistics to illustrate the usefulness of this concept. Stable convergence holds in many limit theorems of probability theory and statistics – such as the classical central limit theorem – which are usually formulated in terms of convergence in distribution. Originated by Alfred Rényi, the notion of stable convergence is stronger than the classical weak convergence of probability measures. A variety of methods is described which can be used to establish this stronger stable convergence in many limit theorems which were originally formulated only in terms of weak convergence. Naturally, these stronger limit theorems have new and stronger consequences which should not be missed by neglecting the notion of stable convergence. The presentation will be accessible to researchers and advanced students at the master's level...

  14. Sentinel node biopsy in penile cancer

    DEFF Research Database (Denmark)

    Jakobsen, J. K.; Krarup, K. P.; Sommer, P.

    2015-01-01

    INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow-up. In th......INTRODUCTION & OBJECTIVES: Nodal involvement is a strong prognosticator in penile cancer and lymph node staging is crucial. Sentinel node biopsy (SNB) has proven a useful staging tool with few complications, but evidence rely mostly on single institution publications with a short follow...... died from complications. CONCLUSIONS: To our knowledge, this is the first complete national study on sentinel node biopsy. Penile cancer sentinel node biopsy with a close follow-up is a reliable lymph node staging and has few complications in a national multicentre setting. Inguinal lymph node...

  15. Computed tomography guidance for skeletal biopsy

    International Nuclear Information System (INIS)

    Frager, D.H.; Goldman, M.J.; Elkin, C.M.; Cynamon, J.; Leeds, N.E.; Seimon, L.P.; Habermann, E.T.; Schreiber, K.; Freeman, L.M.

    1987-01-01

    Computed tomographic (CT) guided biopsy and abscess drainage of multiple organ systems have been well described. Reports of spinal and skeletal applications have been less common. This study describes the use of CT guidance in the biopsy of various skeletal lesions in 46 patients. Forty-one patients had skinny needle aspirations (18 or 22 gauge) and 23 patients had trephine core biopsies. Sites of the lesions included: thoracic spine - 15 patients, lumbosacral spine - 17 patients, bony pelvis - 6 patients, rib - 2 patients, and long bones - 6 patients. Fast scanners capable of rapid image reconstruction have overcome many constraints. With CT guidance, the physician who performs the procedure receives virtually no ionizing radiation. The exact location of the needle tip is accurately visualized in relation to the lesion being biopsied and to the vital organs. (orig.)

  16. Magnetic Resonance (MR)-Guided Breast Biopsy

    Science.gov (United States)

    ... over time. top of page What are the benefits vs. risks? Benefits The procedure is less invasive than surgical biopsy, ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  17. GoM Coastal Biopsy Surveys - NRDA

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Small vessel surveys were conducted within estuarine and nearshore coastal waters of Barataria Bay, LA and Mississippi Sound, MS to collect tissue biopsy samples...

  18. morphological pattern of endometrial biopsies in south

    African Journals Online (AJOL)

    Method: A retrospective study was undertaken to review all cases of endometrial biopsies ... MATERIALS AND METHODS. A retrospective ... tumours, 10 (0.4%) mixed tumours, 14 (0.6%) ..... accurate and concise clinical information on the.

  19. Outpatient percutaneous renal biopsy in adult patients

    International Nuclear Information System (INIS)

    Al-Hweish, Abdulla K.; Abdul-Rehman, I. Saeed

    2007-01-01

    To study the safety and efficacy of performing percutanaeous renal biopsy in the outpatient department compared to the traditional inpatient policy, we studied 44 consecutive patients with proteinuria and other urinary sediment abnormalities, at King Fahd Hospital of the University, Al-Khobar, Saudi Arabia, during the period from September 2004 to August 2006. The patients were divided into two groups: group I, in whom kidney biopsy was performed and followed by 1-day hospital admission; and group II, in whom renal biopsy was performed in the outpatient department and followed by 6 hours observation period and then by regular outpatient visits. All biopsies were performed with the use of real-time ultrasound and automated biopsy needle. Patients with a history of bleeding diathesis or abnormal coagulation profile and those receiving warfarin, heparin, aspirin or nonsteroidal anti-inflammatory drugs were excluded from the study. Only minor biopsy-related complications such as gross hematuria, perinephric hematoma that resolved without the need for blood transfusion or surgical intervention occurred in three (13.6%) patients in group I and in two (9.1%) patients in group II. The complications were apparent within 6 hours in all but one patient (97.7%). Overall, hematuria was identified in 52% of patients at <-72 hours, 85% at <-4 hours and 97.7% at <- 6 hours. The 24-hour hematocrit levels were not significantly different between the study groups. One (4.5%) patient from group II had a small perinephric hematoma, which was detected by ultrasound examination at 24 hours but not at 6 hours post biopsy period; it resolved spontaneously without intervention. We conclude that in selected patients, same day discharge after 6 hours of renal biopsy may be given safety without increased risk of complications. (author)

  20. Single-Pass Percutaneous Liver Biopsy for Diffuse Liver Disease Using an Automated Device: Experience in 154 Procedures

    International Nuclear Information System (INIS)

    Rivera-Sanfeliz, Gerant; Kinney, Thomas B.; Rose, Steven C.; Agha, Ayad K.M.; Valji, Karim; Miller, Franklin J.; Roberts, Anne C.

    2005-01-01

    Purpose: To describe our experience with ultrasound (US)-guided percutaneous liver biopsies using the INRAD 18G Express core needle biopsy system.Methods: One hundred and fifty-four consecutive percutaneous core liver biopsy procedures were performed in 153 men in a single institution over 37 months. The medical charts, pathology reports, and radiology files were retrospectively reviewed. The number of needle passes, type of guidance, change in hematocrit level, and adequacy of specimens for histologic analysis were evaluated.Results: All biopsies were performed for histologic staging of chronic liver diseases. The majority of patients had hepatitis C (134/153, 90.2%). All patients were discharged to home after 4 hr of postprocedural observation. In 145 of 154 (94%) biopsies, a single needle pass was sufficient for diagnosis. US guidance was utilized in all but one of the procedures (153/154, 99.4%). The mean hematocrit decrease was 1.2% (44.1-42.9%). Pain requiring narcotic analgesia, the most frequent complication, occurred in 28 of 154 procedures (18.2%). No major complications occurred. The specimens were diagnostic in 152 of 154 procedures (98.7%).Conclusions: Single-pass percutaneous US-guided liver biopsy with the INRAD 18G Express core needle biopsy system is safe and provides definitive pathologic diagnosis of chronic liver disease. It can be performed on an outpatient basis. Routine post-biopsy monitoring of hematocrit level in stable, asymptomatic patients is probably not warranted

  1. Ultrasound-guided percutaneous renal biopsy with an automated biopsy gun in diffuse renal disease

    International Nuclear Information System (INIS)

    Kim, Ji Yang; Moon, Jeoung Mi; Park, Ji Hyun; Kwon, Jae Soo; Song, Ik Hoon; Kim, Sung Rok

    1994-01-01

    We evaluated the effectiveness and clinical usefulness of percutaneous renal biopsy by using automated biopsy gun under the real-time ultrasonographic guidance that was performed in 17 patients with diffuse renal disease. We retrospectively analysed the histopathological diagnosis and the patients' status after percutaneous renal biopsy.Adequate amount of tissue for the histologic diagnosis could be obtained in al patients. Histopathologic diagnosis included the minimal change nephrotic syndrome in 6 patients, the membrano proliferative glomerulonephritis in 4,the membranous glomerulonephritis in 2, the glomerulosclerosis in 2, Ig A nephropathy in 2, and the normal finding in 1. Significant complication occurred in only one patient who developed a transient loss of sensation at and around the biopsy site. In conclusion, automated biopsy gun was a very useful device in performing percutaneous biopsy for diffuse renal disease with a high success rate and a low complication rate

  2. Gas and particle concentrations in horse stables with individual boxes as a function of the bedding material and the mucking regimen.

    Science.gov (United States)

    Fleming, K; Hessel, E F; Van den Weghe, H F A

    2009-11-01

    The aim of this study was to compare different types of bedding and mucking regimens used in horse stables on the generation of airborne particulate matter bedding material (wheat straw, straw pellets, and wood shavings) used for horses were assessed according to their ammonia generation. Each type of bedding was used for 2 wk, with 3 repetitions. The mean ammonia concentrations within the stable were 3.07 +/- 0.23 mg/m(3) for wheat straw, 4.79 +/- 0.23 mg/m(3) for straw pellets, and 4.27 +/- 0.17 mg/m(3) for wood shavings. In Exp. 2, the effects of the mucking regimen on the generation of ammonia and PM10 from wheat straw (the bedding with the least ammonia generation in the previous experiment) were examined using 3 different daily regimens: 1) no mucking out, 2) complete mucking out, and 3) partial mucking out (removing only feces). The mean ammonia concentrations in the stable differed significantly among all 3 mucking regimens (P bedding regimen without mucking out was evaluated with regard to gas and airborne particle generation. The ammonia values were found not to increase constantly during the course of the 6-wk period. The average weekly values for PM10 also did not increase constantly but varied between approximately 90 and 140 microg/m. It can be concluded from the particle and gas generation patterns found in the results of all 3 experiments that wheat straw was the most suitable bedding of the 3 types investigated and that mucking out completely on a daily basis should not be undertaken in horse stables.

  3. β-Amyloid binding in elderly subjects with declining or stable episodic memory function measured with PET and [{sup 11}C]AZD2184

    Energy Technology Data Exchange (ETDEWEB)

    Mattsson, Patrik [Karolinska Institutet, Centre for Psychiatry Research, Department of Clinical Neuroscience, Stockholm (Sweden); Karolinska University Hospital, Karolinska Institutet, Department of Clinical Neuroscience, Centre for Psychiatry Research, Stockholm (Sweden); Forsberg, Anton; Halldin, Christer [Karolinska Institutet, Centre for Psychiatry Research, Department of Clinical Neuroscience, Stockholm (Sweden); Persson, Jonas; Nilsson, Lars-Goeran [Karolinska Institute and Stockholm University, Aging Research Center (ARC), Stockholm (Sweden); Nyberg, Lars [Umeaa University, Department of Radiation Sciences (Diagnostic Radiology), Umeaa (Sweden); Farde, Lars [Karolinska Institutet, Centre for Psychiatry Research, Department of Clinical Neuroscience, Stockholm (Sweden); AstraZeneca Translational Science Center at Karolinska Institutet, Stockholm (Sweden)

    2015-09-15

    Cognitive decline has been suggested as an early marker for later onset of Alzheimer's disease. We therefore explored the relationship between decline in episodic memory and β-amyloid using positron emission tomography (PET) and [{sup 11}C]AZD2184, a radioligand with potential to detect low levels of amyloid deposits. Healthy elderly subjects with declining (n = 10) or stable (n = 10) episodic memory over 15 years were recruited from the population-based Betula study and examined with PET. Brain radioactivity was measured after intravenous administration of [{sup 11}C]AZD2184. The binding potential BP{sub ND} was calculated using linear graphical analysis with the cerebellum as reference region. The binding of [{sup 11}C]AZD2184 in total grey matter was generally low in the declining group, whereas some binding could be observed in the stable group. Mean BP{sub ND} was significantly higher in the stable group compared to the declining group (p = 0.019). An observation was that the three subjects with the highest BP{sub ND} were ApoE ε4 allele carriers. We conclude that cognitive decline in the general population does not seem to stand by itself as an early predictor for amyloid deposits. (orig.)

  4. β-Amyloid binding in elderly subjects with declining or stable episodic memory function measured with PET and [11C]AZD2184

    International Nuclear Information System (INIS)

    Mattsson, Patrik; Forsberg, Anton; Halldin, Christer; Persson, Jonas; Nilsson, Lars-Goeran; Nyberg, Lars; Farde, Lars

    2015-01-01

    Cognitive decline has been suggested as an early marker for later onset of Alzheimer's disease. We therefore explored the relationship between decline in episodic memory and β-amyloid using positron emission tomography (PET) and [ 11 C]AZD2184, a radioligand with potential to detect low levels of amyloid deposits. Healthy elderly subjects with declining (n = 10) or stable (n = 10) episodic memory over 15 years were recruited from the population-based Betula study and examined with PET. Brain radioactivity was measured after intravenous administration of [ 11 C]AZD2184. The binding potential BP ND was calculated using linear graphical analysis with the cerebellum as reference region. The binding of [ 11 C]AZD2184 in total grey matter was generally low in the declining group, whereas some binding could be observed in the stable group. Mean BP ND was significantly higher in the stable group compared to the declining group (p = 0.019). An observation was that the three subjects with the highest BP ND were ApoE ε4 allele carriers. We conclude that cognitive decline in the general population does not seem to stand by itself as an early predictor for amyloid deposits. (orig.)

  5. Liver Biopsies for Chronic Hepatitis C: Should Nonultrasound-Guided Biopsies Be Abandoned?

    Directory of Open Access Journals (Sweden)

    Jennifer A Flemming

    2009-01-01

    Full Text Available BACKGROUND/OBJECTIVE: Liver biopsy has been the gold standard for grading and staging chronic hepatitis C virus (HCV-mediated liver injury. Traditionally, this has been performed by trained practitioners using a nonimage-guided percutaneous technique at the bedside. Recent literature suggests an expanding role for radiologists in obtaining biopsies using an ultrasound (US-guided technique. The present study was undertaken study to determine if the two techniques produced liver biopsy specimens of similar quality and hypothesized that at our institution, non-US-guided percutaneous liver biopsies for HCV would be of higher quality than US-guided specimens.

  6. stableGP

    Data.gov (United States)

    National Aeronautics and Space Administration — The code in the stableGP package implements Gaussian process calculations using efficient and numerically stable algorithms. Description of the algorithms is in the...

  7. Angina Pectoris (Stable Angina)

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Angina Pectoris (Stable Angina) Updated:Aug 21,2017 You may have heard the term “angina pectoris” or “stable angina” in your doctor’s office, ...

  8. Image-guided procedures in brain biopsy.

    Science.gov (United States)

    Fujita, K; Yanaka, K; Meguro, K; Narushima, K; Iguchi, M; Nakai, Y; Nose, T

    1999-07-01

    Image-guided procedures, such as computed tomography (CT)-guided stereotactic and ultrasound-guided methods, can assist neurosurgeons in localizing the relevant pathology. The characteristics of image-guided procedures are important for their appropriate use, especially in brain biopsy. This study reviewed the results of various image-guided brain biopsies to ascertain the advantages and disadvantages. Brain biopsies assisted by CT-guided stereotactic, ultrasound-guided, Neuronavigator-guided, and the combination of ultrasound and Neuronavigator-guided procedures were carried out in seven, eight, one, and three patients, respectively. Four patients underwent open biopsy without a guiding system. Twenty of 23 patients had a satisfactory diagnosis after the initial biopsy. Three patients failed to have a definitive diagnosis after the initial procedure, one due to insufficient volume sampling after CT-guided procedure, and two due to localization failure by ultrasound because the lesions were nonechogenic. All patients who underwent biopsy using the combination of ultrasound and Neuronavigator-guided methods had a satisfactory result. The CT-guided procedure provided an efficient method of approaching any intracranial target and was appropriate for the diagnosis of hypodense lesions, but tissue sampling was sometimes not sufficient to achieve a satisfactory diagnosis. The ultrasound-guided procedure was suitable for the investigation of hyperdense lesions, but was difficult to localize nonechogenic lesions. The combination of ultrasound and Neuronavigator methods improved the diagnostic accuracy even in nonechogenic lesions such as malignant lymphoma. Therefore, it is essential to choose the most appropriate guiding method for brain biopsy according to the radiological nature of the lesions.

  9. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P guided diagnostic breast biopsy procedure. Significantly more (P guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information. PMID:21835024

  10. Oral biopsy: Oral pathologist′s perspective

    Directory of Open Access Journals (Sweden)

    K L Kumaraswamy

    2012-01-01

    Full Text Available Many oral lesions may need to be diagnosed by removing a sample of tissue from the oral cavity. Biopsy is widely used in the medical field, but the practice is not quite widespread in dental practice. As oral pathologists, we have found many artifacts in the tissue specimen because of poor biopsy technique or handling, which has led to diagnostic pitfalls and misery to both the patient and the clinician. This article aims at alerting the clinicians about the clinical faults arising preoperatively, intraoperatively and postoperatively while dealing with oral biopsy that may affect the histological assessment of the tissue and, therefore, the diagnosis. It also reviews the different techniques, precautions and special considerations necessary for specific lesions.

  11. Isolate pulmonary nodule. CT-guided biopsy

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Ettore, F.; Rogopoulos, A.; Geoffray, A.; Balu-Maestro, C.; Le Houcq, M.

    1989-01-01

    Transparietal CT-guided biopsy location can be successfully performed for isolate pulmonary nodules, defined as lesions with a maximal diameter of 3 cm, without any other parenchymal or mediastinal abnormality. A 21 G needle has been used according to an identical protocole in 64 cases (10 benign, 54 malignant). The biopsy was successful in 77.7% of the malignant cases. In relation to the diameter of the nodules, biopsy was successful in 66.7% of the nodules smaller than 2 cm and in 76% of the nodules ranging from 2 to 3 cm. The complications observed were rare (1 case of pneumothorax requiring drainage, 9 cases of pneumothorax without clinical signs and simply followed up, 4 cases of minor hemoptysis requiring no treatment and 5 cases of hematomas smaller than 5 cm on CT) [fr

  12. Comparative study of decomposable and indecomposable biopsy needle in lung puncture biopsy

    International Nuclear Information System (INIS)

    Wang Bo; Sheng Zhanxin; Wen Yamin; Zhang Liping; Wen Zongqiu

    2007-01-01

    Objective: To contrast the clinical practice characteristics with decomposable and indecomposable biopsy needle in the CT-guided lung puncture biopsy. Methods: 50 patients with lung tumour carried on puncture biopsy under the CT guidance were divided in two groups randomly: Group A (25 examples): using the indecomposable BioPinceTM biopsy needle; Group B(25 examples): using the decomposable Precisa or Vitesse biopsy needle. The puncture biopsy organization quantity, the first time puncture success rate, the pathological diagnosis result and the incidence of puncture complication were compared in two groups. Results: More striped structures were gained obviously in group A than in group B: 24/25 and 11/25 respectively (P>0.05), The pathological diagnosis 'serious extrusion amoebocyte and nature undetermined' only occurred in group B. But the first time puncture success rate was lower in group A than in B: 52%(13/25) and 80%(20/25) respectively (P>0.05), The incidence of hemorrhage and pneumothorax in group A was higher slightly: 84% and 72%, 16% and 4% respectively (P>0.05). Conclusion: The indecomposable needle (BioPinceTM) was better in lung puncture biopsy, but the lower first time puncture success rate also increases the risk of operation and complication in some degree because of the structure of the needle. On the contrary, decomposable needle (the Precisa or the Vitesse) was not the best choice in lung puncture biopsy. But it had the original superiority, especially regarding the special patient such as patient with small tumour, thin thoracic wall, bad physique for its nimble operation. It is essential for us to use the two different types of biopsy needle rationally to enhance the level of CT-guided lung puncture biopsy. (authors)

  13. Endobronkial ultralydsskanning af mediastinum med biopsi

    DEFF Research Database (Denmark)

    Siemsen, Mette; Steffensen, Ida E; Iversen, Martin

    2010-01-01

    Endobronchial ultrasound (EBUS) is a minimally invasive diagnostic modality, by which it is possible to visualize and do biopsy of structures adjacent to the trachea and the central bronchial system. EBUS is mostly used for staging of lung cancer patients, but EBUS is now used worldwide as a diag......Endobronchial ultrasound (EBUS) is a minimally invasive diagnostic modality, by which it is possible to visualize and do biopsy of structures adjacent to the trachea and the central bronchial system. EBUS is mostly used for staging of lung cancer patients, but EBUS is now used worldwide...

  14. Liver biopsy in liver patients with coagulopathy

    DEFF Research Database (Denmark)

    Ott, P.; Gronbaek, H.; Clausen, M.R.

    2008-01-01

    The risk of severe bleeding after liver biopsy is estimated to be 1:12,000 in patients with near normal coagulation (INR 60 billion /l). Beyond these limits, the risk is higher, but still uncertain. The Danish guidelines require INR > 1.5, platelet count ... and normal APTT. In some instances the risk of not knowing the histology is so high that a biopsy is considered even with a more disturbed coagulation. Vitamin K, freshly frozen plasma and recombinant activated factor VII may reduce the risk of bleeding in specific situations, but no firm recommendations can...

  15. Ultrasound-guided biopsy and drainage

    International Nuclear Information System (INIS)

    Ott, R.C.; Wellauer, J.

    1985-01-01

    This book discusses the ultrasound (US) biopsy techniques, cytology, histology, and physics. The emphasis is on use of US guidance, as the authors find that virtually all lesions are visible at US scanning and they thus save valuable time on the computer tomographic scanner. The authors present in great detail their considerable work in designing needles that are readily visible at US scanning and can also collect good cytologic and histologic material. Biopsy techniques are discussed separately for each organ system. The accuracy of these techniques in over 3,000 of the author's cases is presented

  16. Dermatofibrosarcoma protuberans diagnosed by a single biopsy

    Directory of Open Access Journals (Sweden)

    Kristian Bakke Arvesen

    2012-07-01

    Full Text Available This brief report is about a 9 year old girl presenting with a 2.5 cm circular blue to violet discoloration on the anterolateral upper left thigh. The first biopsy taken revealed the diagnosis dermatofibrosarcoma protuberans. The patient underwent surgery at a specialized sarcoma center with post operative histology showing free wide resection margin. Preoperative chest x-ray showed no sign of metastasis. This brief report emphasizes the significance of the use of biopsy when cutaneous elements look suspicious and diagnosis is unclear.

  17. Sentinel lymph node biopsy in oral cancer

    DEFF Research Database (Denmark)

    Thomsen, Jørn Bo; Sørensen, Jens Ahm; Grupe, Peter

    2005-01-01

    PURPOSE: To validate lymphatic mapping combined with sentinel lymph node biopsy as a staging procedure, and to evaluate the possible clinical implications of added oblique lymphoscintigraphy and/or tomography and test the intra- and interobserver reproducibility of lymphoscintigraphy. MATERIAL......: Eleven (28%) patients were upstaged. The sentinel lymph node identification rate was 97.5%. Sentinel lymph node biopsy significantly differentiated between patients with or without lymph node metastasis (P = 0.001). Lymphatic mapping revealed 124 hotspots and 144 hot lymph nodes were removed by sentinel...

  18. Can zero-hour cortical biopsy predict early graft outcomes after living donor renal transplantation?

    Science.gov (United States)

    Rathore, Ranjeet Singh; Mehta, Nisarg; Mehta, Sony Bhaskar; Babu, Manas; Bansal, Devesh; Pillai, Biju S; Sam, Mohan P; Krishnamoorthy, Hariharan

    2017-11-01

    The aim of this study was to identify relevance of subclinical pathological findings in the kidneys of living donors and correlate these with early graft renal function. This was a prospective study on 84 living donor kidney transplant recipients over a period of two years. In all the donors, cortical wedge biopsy was taken and sent for assessment of glomerular, mesangial, and tubule status. The graft function of patients with normal histology was compared with those of abnormal histological findings at one, three, and six months, and one year post-surgery. Most abnormal histological findings were of mild degree. Glomerulosclerosis (GS, 25%), interstitial fibrosis (IF, 13%), acute tubular necrosis (ATN 5%), and focal tubal atrophy (FTA, 5%) were the commonly observed pathological findings in zero-hour biopsies. Only those donors who had histological changes of IF and ATN showed progressive deterioration of renal function at one month, three months, six months, and one year post-transplantation. In donors with other histological changes, no significant effect on graft function was observed. Zero-hour cortical biopsy gave us an idea of the general status of the donor kidney and presence or absence of subclinical pathological lesions. A mild degree of subclinical and pathological findings on zero-hour biopsy did not affect early graft renal function in living donor kidney transplantation. Zero-hour cortical biopsy could also help in discriminating donor-derived lesions from de novo alterations in the kidney that could happen subsequently.

  19. CT-guided biopsy of pulmonary lesions : a comparison of diagnostic accuracy and complication rate between automated gun biopsy and fine needle aspiration biopsy

    International Nuclear Information System (INIS)

    Kim, Keon Woo; Kang, Duk Sik

    1998-01-01

    The purpose of this study is to compare the efficacy and safety of CT-guided automated gun biopsy with those of fine needle aspiration biopsy of pulmonary lesions. Under CT guidance, we performed automated gu biopsies in 115 cases of 109 patients and fine needle aspiration biopsies in 119 cases of 108 patients with pulmonary lesions. Between the two methods, we compared the diagnostic rate, diagnostic accuracy and frequency of compilations according to the depth and diameter of pulmonary lesions. The overall diagnostic rates of automated gun biopsy and fine needle aspiration biopsy were 76.5 % (88/115) and 64.7 % (77/119) respectively. There was a significant statistical difference (p=0.048), especially in the case of malignant lesions less than 3 cm (p=0.027) and more than 6 cm in maximal diameter (p=0.008), and in the lesions located from 1 cm to less than 3 cm from the pleural (p=0.030), as seen on CT. There was no significant statistical difference in the frequency of complications. Automated gun biopsy of pulmonary lesions under CT guidance is safe, with complications rate comparable to those of fine needle aspiration biopsy. A higher overall diagnostic rate can be achieved by automated gun biopsy than by fine needle aspiration biopsy. For the diagnosis of pulmonary lesions under CT guidance, automated gun biopsy is therefore a more useful procedure than fine needle aspiration biopsy. (author). 24 refs., 3 tabs

  20. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk [Kosin Medical College, Pusan (Korea, Republic of)

    1998-02-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs.

  1. Transjugular liver biopsy : the efficacy of quick-core biopsy needle system

    International Nuclear Information System (INIS)

    Jung, Gyoo Sik; Ahn, Byung Kwon; Lee, Sang Ouk; Chang, Hee Kyong; Oh, Kyung Seung; Huh, Jin Do; Joh, Young Duk

    1998-01-01

    To evaluate the efficacy of the Quick-Core biopsy needle system in performing transjugular liver biopsy. Between December 1995 and June 1997, eight patients underwent transjugular liver biopsy involving use of the Quick-Core biopsy needle system; the conditions involved were coagulopathy (n=4), thrombocytopenia (n=3), and ascites (n=1). Via the right internal jugular vein, the right hepatic vein was selectively catheterized with a 7-F transjugular guiding catheter, and a14-guage stiffening cannula was then inserted through this catheter; to obtain core tissue, a Quick-Core needle was then advanced into the liver parenchyma through the catheter-cannula combination. Eighteen- and 19-guage needles were used in three and five patients, respectively; specimen size, adequacy of the biopsy specimen and histologic diagnosis were determined, and complications were recorded. Biopsy was successful in all patients. The mean length of the specimen was 1.4 cm (1.0 - 1.8 cm), and all were adequate for pathologic examinations ; specific diagnosis was determined in all patients. There were two malignant neoplasms, two cases of veno-occlusive disease, and one case each of cirrhosis, fulminant hepatitis, Banti syndrome and Budd-Chiari syndrome. One patient complained of neck pain after the procedure, but no serious procedural complications were noted. Our preliminary study shows that the Quick-Core biopsy needle system is safe and provides adequate core tissues with high diagnostic yields. (author). 23 refs., 1 tab., 3 figs

  2. Stable Boundary Layer Issues

    OpenAIRE

    Steeneveld, G.J.

    2012-01-01

    Understanding and prediction of the stable atmospheric boundary layer is a challenging task. Many physical processes are relevant in the stable boundary layer, i.e. turbulence, radiation, land surface coupling, orographic turbulent and gravity wave drag, and land surface heterogeneity. The development of robust stable boundary layer parameterizations for use in NWP and climate models is hampered by the multiplicity of processes and their unknown interactions. As a result, these models suffer ...

  3. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany); Gabbert, H.E. [University Dusseldorf, Medical Faculty, Department of Pathology, Dusseldorf (Germany)

    2016-11-15

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  4. Stereotactic core biopsy: Comparison of 11 gauge with 8 gauge vacuum assisted breast biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Shambhavi, E-mail: svenkata@bidmc.harvard.edu [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Dialani, Vandana [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Gilmore, Hannah L. [Department of Pathology, UH Case Medical Center, 11100 Euclid Ave, Cleveland, OH 44106 (United States); Mehta, Tejas S. [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States)

    2012-10-15

    Purpose: The compare the performance and ability to obtain a correct diagnosis on needle biopsy between 11 gauge and 8 gauge vacuum assisted biopsy devices. Materials and methods: Hospital records of all consecutive stereotactic core biopsies performed over five years were retrospectively reviewed in compliance Health Insurance Portability and Accountability Act (HIPPA) policy and with approval from the hospital institutional review board (IRB). Pathology from core biopsy was compared with surgical pathology and/or imaging follow-up. A histological underestimation was defined if the surgical excision yielded a higher grade on pathology which changed management. Results: 828 needle core biopsies (47.5%, 393/828 with 11 gauge and 52.5%, 435/828 with 8 gauge) yielded 471 benign, 153 high risk and 204 malignant lesions. 30/193 (15.5%) 11 gauge lesions and 16/185 (8.6%) 8 gauge lesions demonstrated higher grade pathology on surgical excision. The difference in the rates of the number of correct diagnoses on core needle biopsy between 11 gauge (363/393, 92.4%) and 8 gauge (419/435, 96.3%) based on either surgical or clinical/imaging follow up and the difference in the number of discordant benign core biopsies between 11 (17/217, 7.8%) and 8 gauge (4/254, 1.6%) necessitating a surgical biopsy was significant (P = 0.013; P = 0.001). Although there were more underestimations with the 11 gauge (25/193, 13.0%) than 8 gauge (15/185, 8.1%) needle, this was not significant. Conclusion: Our study demonstrates improved performance and increased diagnostic ability of 8 gauge needle over 11 gauge in obtaining a correct diagnosis on needle biopsy.

  5. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    International Nuclear Information System (INIS)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G.; Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C.; Gabbert, H.E.

    2016-01-01

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  6. Core biopsies of the breast: Diagnostic pitfalls

    Directory of Open Access Journals (Sweden)

    Megha Joshi

    2011-01-01

    Full Text Available The incidence of breast cancer is increasing worldwide. In this review article, the authors compare and contrast the incidence of breast cancer, and the inherent differences in the United States (US and India in screening techniques used for diagnosing breast cancer. In spite of these differences, core biopsies of the breast are common for diagnosis of breast cancer in both countries. The authors describe "Best Practices" in the reporting and processing of core biopsies and in the analysis of estrogen receptor (ER, progesterone receptor (PR, and human epidermal growth factor Receptor 2 (Her2/neu. The pitfalls in the diagnosis of fibroepithelial lesions of the breast on core biopsy are discussed, as also the significance of pseudoangiomatous stromal hyperplasia of the breast (PASH is discussed in core biopsy. In this review, the management and diagnosis of flat epithelial atypia and radiation atypia are elaborated and the use of immunohistochemistry (IHC in papillary lesions, phyllodes tumor, and complex sclerosing lesions (radial scars is illustrated. Rarer lesions such as mucinous and histiocytoid carcinoma are also discussed.

  7. Ultrasound- and MRI-Guided Prostate Biopsy

    Science.gov (United States)

    ... assistance of a nurse and an MR imaging technologist. As with the ultrasound procedure, you may receive antibiotics, sedatives and pain medication before the biopsy. The MRI-guided procedure may use contrast ... A nurse or technologist will insert an intravenous (IV) catheter into a ...

  8. Liver biopsy — the current view?

    African Journals Online (AJOL)

    needles, or the more recent cutting-core automated or semi-automated needles. These may be single units, or part of gun-type system with disposable needles. The pathologist's requirements of the specimen depend on whether diffuse disease or focal lesions are biopsied. The ideal tissue core for diffuse disease should be ...

  9. Protective Capnothorax During Transthoracic Needle Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kavanagh, John, E-mail: jokavana@tcd.ie; Siemienowicz, Miranda L.; Lyen, Stephen; Kandel, Sonja; Rogalla, Patrik [University of Toronto, Division of Cardiothoracic Imaging, Joint Department of Medical Imaging, University Health Network and Mount Sinai Hospital (Canada)

    2017-04-15

    PurposeTransthoracic needle biopsy (TTNB) is an established procedure in the management of pulmonary nodules. The most common complications are directly related to crossing the lung or visceral pleura during the biopsy. In this study, we describe the use of carbon dioxide instead of room air to create a protective “capnothorax” during TTNB.Materials and MethodsFive patients underwent creation of a capnothorax during TTNB. Parameters recorded were location and size of target, distance from pleura, length of procedure, volume of carbon dioxide, periprocedural complications and biopsy result.ResultsInduction of capnothorax was successful in all cases. In two patients, a continuous infusion of carbon dioxide was required to maintain an adequate volume of intrapleural gas. In two patients, the carbon dioxide resolved spontaneously and in the remaining patients it was aspirated at the end of the procedure. All biopsies were diagnostic with no periprocedural or postprocedural complications.ConclusionThis study suggests that protective iatrogenic capnothorax is a safe and effective technique during TTNB. The intrinsic properties and availability of carbon dioxide make it an attractive alternative to room air.

  10. Unusual presentation and inconclusive biopsy render fibroadenoma ...

    African Journals Online (AJOL)

    Two young, nonlactating, nulliparous women presented with acutely painful breast masses. Sonographic features showed mixed echogenic masses. Core biopsies were not diagnostic, and surgical excision revealed infarcted fibroadenomas in both cases. Although fibroadenomas are common, they do not commonly infarct, ...

  11. EFFICACY OF IMMUNOHISTOCHEMISTRY IN PROSTATE NEEDLE BIOPSIES

    Directory of Open Access Journals (Sweden)

    Tameem Afroz

    2016-10-01

    Full Text Available BACKGROUND Prostate needle biopsies can pose a major diagnostic challenge when it comes to differentiating adenocarcinoma and its variants from its benign mimics. In needle biopsies, when the suspicious focus is small, morphological features may not suffice to differentiate it from its morphologic mimics like atrophy, basal cell hyperplasia, reactive inflammatory changes, seminal vesicles and adenosis. Immunohistochemical marker for basal cells, p63 and prostate cancer specific marker, Alpha-Methylacyl-CoA Racemase (AMACR help in overcoming such diagnostic dilemmas. MATERIALS AND METHODS We analysed 157 prostate core needle biopsies over a period of 2 years. Routine Hematoxylin and Eosin (H and E sections and immunohistochemical markers for basal cells (p63 and prostate cancer specific marker (AMACR were used. Prospective study was done on prostate needle core biopsies. Biopsy was done under ultrasound guidance with an 18-gauge needle. Biopsy was done in patients with raised serum PSA levels for exclusion of prostate carcinoma. RESULTS Over a period of two years, 157 prostate core needle biopsies were studied. 83 were benign lesions comprising 69 benign prostatic hyperplasias, five basal cell hyperplasias, four granulomatous lesions and three showed atrophic changes. Two biopsies morphologically resembled seminal vesicles. Prostate cancer specific marker, AMACR was negative in all, but two lesions. In these two lesions, it showed weak nonspecific staining. Basal cell marker p63 showed a continuous staining pattern highlighting the basal cells in all the 69 cases of benign prostatic hyperplasia, 5 cases of basal hyperplasia showed positivity in all the hyperplastic basal cells. In the two cases of seminal vesicles, it showed intense basal cell positivity. It showed a discontinuous pattern in two of the four granulomatous lesions and showed a weak, but a continuous staining pattern in the atrophic lesions. 74 were adenocarcinomas; the predominant

  12. Design and functionality of a segmented heat-storage prototype utilizing stable supercooling of sodium acetate trihydrate in a solar heating system

    DEFF Research Database (Denmark)

    Englmair, Gerald; Moser, Christoph; Furbo, Simon

    2018-01-01

    acetate trihydrate composites to conserve the latent heat of fusion for long-term heat storage. A control strategy directed heat from a solar collector array to either the PCM storage or a water buffer storage. Several PCM units had to be charged in parallel when the solar collector output peaked at 16 k......A solar heating system with 22.4m2 of solar collectors, a heat storage prototype consisting of four 200 kg phase-change material (PCM) storage units, and a 735 L water tank was designed to improve solar heat supply in single-family houses. The PCM storage utilized stable supercooling of sodium......W. A single unit was charged with 27.4 kWh of heat within four hours on a sunny day, and the PCM temperature increased from 20 °C to 80 °C. The sensible heat from a single PCM unit was transferred to the water tank starting with about 32 kW of thermal power after it had fully melted at 80 °C. A mechanical...

  13. Stable isotopes labelled compounds

    International Nuclear Information System (INIS)

    1982-09-01

    The catalogue on stable isotopes labelled compounds offers deuterium, nitrogen-15, and multiply labelled compounds. It includes: (1) conditions of sale and delivery, (2) the application of stable isotopes, (3) technical information, (4) product specifications, and (5) the complete delivery programme

  14. Evolutionary Stable Strategy

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 21; Issue 9. Evolutionary Stable Strategy: Application of Nash Equilibrium in Biology. General Article Volume 21 Issue 9 September 2016 pp 803- ... Keywords. Evolutionary game theory, evolutionary stable state, conflict, cooperation, biological games.

  15. Stable Boundary Layer Issues

    NARCIS (Netherlands)

    Steeneveld, G.J.

    2012-01-01

    Understanding and prediction of the stable atmospheric boundary layer is a challenging task. Many physical processes are relevant in the stable boundary layer, i.e. turbulence, radiation, land surface coupling, orographic turbulent and gravity wave drag, and land surface heterogeneity. The

  16. Multi-institutional Evaluation of Upper Urinary Tract Biopsy Using Backloaded Cup Biopsy Forceps, a Nitinol Basket, and Standard Cup Biopsy Forceps.

    Science.gov (United States)

    Lama, Daniel J; Safiullah, Shoaib; Patel, Roshan M; Lee, Thomas K; Balani, Jyoti P; Zhang, Lishi; Okhunov, Zhamshid; Margulis, Vitaly; Savage, Stephen J; Uchio, Edward; Landman, Jaime

    2018-04-06

    To compare the performance of 3 contemporary ureteroscopic biopsy devices for the histopathologic diagnosis of upper tract urothelial carcinoma (UTUC). We retrospectively reviewed 145 patients who underwent 182 urothelial biopsies using 2.4F backloaded cup biopsy forceps, a nitinol basket, or 3F standard cup biopsy forceps at 3 tertiary academic centers between 2011 and 2016. Experienced genitourinary pathologists provided an assessment of each specimen without knowledge of the device used for biopsy. For patients who underwent nephroureterectomy without neoadjuvant chemotherapy within 3 months of biopsy-proven UTUC diagnosis, the biopsy grade was compared with both the grade and stage of the surgical specimen. Biopsy utilization varied among the 3 institutions (P cup forceps was rated similarly to the nitinol basket (P >.05) and was favored over standard cup forceps specimens. Grade concordance was not affected by specimen size (P >.05), morphology (P >.1), or location (P >.5). No difference existed among the devices in the rate of acquiring a grade concordant biopsy; however, the backloaded cup forceps provided concordant biopsies that could be distinguished as low- and high-grade (P = .02). The backloaded cup forceps and nitinol basket obtained a higher quality urothelial specimen compared with standard cup forceps. Ureteroscopic biopsy device selection did not significantly impact the accuracy of the histologic diagnosis of UTUC. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Complications of percutaneous renal tumor biopsy: An analysis of 340 consecutive biopsies

    DEFF Research Database (Denmark)

    René Rasmussen, Lars; Loft, Martina; Høyer, Søren

    Purpose Ultrasound Guided Percutaneous Kidney Biopsy (UGPKB) plays a major role in diagnosis of renal tumours. There seems to be little consensus regarding post-biopsy observation period. We aim to identify complications in UGPKB among outpatients with a suspected malignant renal lesion as well...... as the timing of onset of these complications, helping to clarify the optimal observation period. Many studies in this field suggest a lower complication risk for outpatients compared to hospitalized patients. In the latter group, an observation period of 24h after biopsy is often recommended. Material...... discrepancy. Results As for one third of the patients, analysed up until now, we find a total of one major complication and a few minor, all arisen within less than 6 hours after biopsy. Conclusions Rates of both major and minor complications in UGPKB are very low suggesting a shorter observation period...

  18. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  19. A comparison of stable-isotope probing of DNA and phospholipid fatty acids to study prokaryotic functional diversity in sulfate-reducing marine sediment enrichment slurries.

    Science.gov (United States)

    Webster, Gordon; Watt, Lynsey C; Rinna, Joachim; Fry, John C; Evershed, Richard P; Parkes, R John; Weightman, Andrew J

    2006-09-01

    Marine sediment slurries enriched for anaerobic, sulfate-reducing prokaryotic communities utilizing glucose and acetate were used to provide the first comparison between stable-isotope probing (SIP) of phospholipid fatty acids (PLFA) and DNA (16S rRNA and dsrA genes) biomarkers. Different 13C-labelled substrates (glucose, acetate and pyruvate) at low concentrations (100 microM) were used over a 7-day incubation to follow and identify carbon flow into different members of the community. Limited changes in total PLFA and bacterial 16S rRNA gene DGGE profiles over 7 days suggested the presence of a stable bacterial community. A broad range of PLFA were rapidly labelled (within 12 h) in the 13C-glucose slurry but this changed with time, suggesting the presence of an active glucose-utilizing population and later development of another population able to utilize glucose metabolites. The identity of the major glucose-utilizers was unclear as 13C-enriched PLFA were common (16:0, 16:1, 18:1omega7, highest incorporation) and there was little difference between 12C- and 13C-DNA 16S rRNA gene denaturing gradient gel electrophoresis (DGGE) profiles. Seemingly glucose, a readily utilizable substrate, resulted in widespread incorporation consistent with the higher extent of 13C-incorporation (approximately 10 times) into PLFA compared with 13C-acetate or 13C-pyruvate. 13C-PLFA in the 13C-acetate and 13C-pyruvate slurries were similar to each other and to those that developed in the 13C-glucose slurry after 4 days. These were more diagnostic, with branched odd-chain fatty acids (i15:0, a15:0 and 15:1omega6) possibly indicating the presence of Desulfococcus or Desulfosarcina sulfate-reducing bacteria (SRB) and sequences related to these SRB were in the 13C-acetate-DNA dsrA gene library. The 13C-acetate-DNA 16S rRNA gene library also contained sequences closely related to SRB, but these were the acetate-utilizing Desulfobacter sp., as well as a broad range of uncultured Bacteria. In

  20. Effects of benzoxazine resin on property enhancement of shape memory epoxy: A dual function of benzoxazine resin as a curing agent and a stable network segment

    Directory of Open Access Journals (Sweden)

    T. Tanpitaksit

    2015-09-01

    Full Text Available An ability of bisphenol-A/aniline based benzoxazine resin (BA-a to simultaneously acts as a curing agent and a stable or rigid network segment for shape memory epoxy, i.e. a two component system, is demonstrated. This significantly simplifies a formulation of present shape memory epoxy systems, i.e. a three or four component system. A suitable content of BA-a in the aliphatic epoxy (NGDE/polybenzoxazine (PBA-a samples for good shape memory performance is in a range of 30 to 50 mol%. The storage modulus of the obtained NGDE/PBA-a shape memory polymers (SMPs was increased from 3.57 GPa for 30 mol% BA-a content to 4.50 GPa for 50 mol% BA-a content. Glass transition temperature of the sample was also substantially increased with increasing BA-a fraction, i.e. from 51°C to 140°C. Flexural modulus and strength at room temperature of the samples at 50 mol% BA-a were found to be as high as 3.97 GPa and 132 MPa compared to the maximum values of 2.54 GPa and 100 MPa of SMP based on cyanate ester-epoxy. All samples exhibited a high value of shape fixity close to 100%. A presence of the BA-a in the samples also imparted a greater recovery stress ranging from 0.25 to 1.59 MPa. Consequently, the obtained NGDE/PBA-a copolymers are highly attractive for shape memory materials to be used in a broader range of applications particularly at elevated temperature and a higher recovery stress value.

  1. Incidental intraductal papillomas (breast diagnosed on needle core biopsy do not need to be excised.

    Science.gov (United States)

    Jaffer, Shabnam; Bleiweiss, Ira J; Nagi, Chandandeep

    2013-01-01

    Most authors recommend excision of intraductal papillomas diagnosed on core needle biopsy. This leads to the question of whether or not excision is necessary for incidental intraductal papillomas on core needle biopsy as opposed to those corresponding to imaging findings. Using the pathology computerized data base we retrospectively identified 46 incidental intraductal papillomas diagnosed on core needle biopsy from 1/2000 to 12/2008. Clinical, radiologic, and pathologic information was gathered and correlated. All core needle biopsies were reviewed to confirm the diagnosis of incidental intraductal papillomas, and excision specimens reviewed when available. Of the 46 patients, follow-up information was available in only 38. The age of the patients ranged from 39 to 82 years (mean = 48 years). Most incidental intraductal papillomas were diagnosed by mammotome core needle biopsy (36 cases). A total of 33 cases were performed for calcifications with the following indications: clustered = 21, new = 4, pleomorphic = 3, increasing = 3, indeterminant = 2. The correlating diagnoses included the following: fibrocystic changes with calcium phosphate = 18 or calcium oxalate = 10, fibroadenoma with calcifications = 5. The three masses were: two cases of cystic papillary apocrine metaplasia (I Ultrasound and 1 MRI) and 1 fibroadenoma (Ultrasound). In all cases, the intraductal papillomas were ≤0.2 cm, were not associated with calcifications, and were incidental to them or the underlying mass. A total of 14 patients underwent excision, whereas the remaining 24 have remained radiologically stable for over 12 months. The excision specimen findings were: fibrocystic changes = 8 and intraductal papilloma = 6. With the exception of one case, all the intraductal papilloma remained incidental to imaging findings. In this solitary case, the calcifications were described as pleomorphic and corresponded to fibrocystic changes calcifications on core needle

  2. HepG2/C3A 3D spheroids exhibit stable physiological functionality for at least 24 days after recovering from trypsination

    DEFF Research Database (Denmark)

    Wrzesinski, Krzysztof; Magnone, Maria Chiara; Hansen, Line Visby

    2013-01-01

    Primary human hepatocytes are widely used as an in vitro system for the assessment of drug metabolism and toxicity. Nevertheless a cell system with higher stability of physiological functions is required for the investigation of drugs’ mode of action, pathway analyses and biomarkers evaluations. ...

  3. A Novel Design of Needle Aspiration Biopsy Monitoring Instrument (NAOMI Tested on a Low Cost Chest Phantom

    Directory of Open Access Journals (Sweden)

    Surakusumah Rino Ferdian

    2016-01-01

    Full Text Available Needle biopsy is a medical intervention method for taking a lung tissue sample that suspected as a cancer. The disadvantage is the physicians directly visualize the anatomical structures in an open surgery for lung cancer biopsy procedure. There is a need to develop an instrument that may help the physician to guarantee the accuracy and efficiency while performing needle aspiration biopsy. Therefore, a needle aspiration biopsy monitoring instrument or named as NAOMI is proposed. It consists of a microcontroller system, an IMU sensor, an ultrasonic ranging module, a bluetooth module, and a 9V lithium battery. The experimental testing consist of performance testing, functional testing using chest phantom, and user acceptances. The results showed that the NAOMI improve the accuracy and efficiency while performing the needle biopsy operation.

  4. Percutaneous biopsy of a metastatic common iliac lymph node using hydrodissection and a semi-automated biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Seong Yoon; Park, Byung Kwan [Dept. of Radiology, amsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-06-15

    Percutaneous biopsy is a less invasive technique for sampling the tissue than laparoscopic biopsy or exploratory laparotomy. However, it is difficult to perform biopsy of a deep-seated lesion because of the possibility of damage to the critical organs. Recently, we successfully performed CT-guided biopsy of a metastatic common iliac lymph node using hydrodissection and semi-automated biopsy devices. The purpose of this case report was to show how to perform hydrodissection and how to use a semi-automated gun for safe biopsy of a metastatic common iliac lymph node.

  5. Monteris AXiiiS Stereotactic Miniframe for Intracranial Biopsy: Precision, Feasibility, and Ease of Use.

    Science.gov (United States)

    Manjila, Sunil; Knudson, Kathleen E; Johnson, Carleton; Sloan, Andrew E

    2016-06-01

    Stereotactic biopsy is an important and minimally invasive technique used for a variety of indications in neurosurgery. Initially, this technique required a frame, but recently there have been a number of newer, less cumbersome approaches to biopsy including robotic arms, fixed arms, and, more recently, skull-mounted miniframes. Miniframes are attractive because they are disposable and low profile. However, the relatively limited degree of freedom offered by currently available devices necessitates a preplanned burr hole, which in turn limits flexibility and multiple trajectories. The AXiiiS device is a skull-mounted, magnetic resonance imaging-compatible miniframe that provides a similar degree of freedom with a frame while maintaining a low-profile, disposable platform. To assess the image-guided trajectory alignment accuracy using AXiiiS stereotactic miniframe biopsy of intracranial lesions. The accuracy of the AXiiiS device is compared with the Navigus Trajectory Guide as platforms. After approval by our institutional review board, medical records of 10 neurosurgical patients with intracranial pathologies were chosen for AXiiiS stereotactic miniframe biopsy, and histological correlation was obtained. Ten reported cases demonstrate the precision and ease of using the AXiiiS stereotactic miniframe for biopsy of intracranial lesions in conjunction with preoperative magnetic resonance imaging. Multiple trajectories and angles have been used with precision and safety. The AXiiiS stereotactic miniframe is a feasible, safe, and disposable platform for multitrajectory intracranial biopsies. Compared with existing platforms, this novel device provides a more stable base and wider limits of trajectory angles with comparable accuracy and precision.

  6. Airway bacteria measured by quantitative polymerase chain reaction and culture in patients with stable COPD: relationship with neutrophilic airway inflammation, exacerbation frequency, and lung function

    Directory of Open Access Journals (Sweden)

    Bafadhel M

    2015-06-01

    Full Text Available Mona Bafadhel,1 Koirobi Haldar,2 Bethan Barker,2,3 Hemu Patel,4 Vijay Mistry,2,3 Michael R Barer,2–4 Ian D Pavord,1 Christopher E Brightling2,3 1Respiratory Medicine Unit, Nuffield Department of Clinical Medicine, University of Oxford, Oxford, UK; 2Department of Infection, Immunity and Inflammation, University of Leicester, 3Institute for Lung Health, National Institute for Health Research Respiratory Biomedical Research Unit, Glenfield Hospital, University of Leicester, 4Department of Clinical Microbiology, University Hospitals of Leicester NHS Trust, Leicester, UK Background: Potentially pathogenic microorganisms can be detected by quantitative real-time polymerase chain reaction (qPCR in sputum from patients with COPD, although how this technique relates to culture and clinical measures of disease is unclear. We used cross-sectional and longitudinal data to test the hypotheses that qPCR is a more sensitive measure of bacterial presence and is associated with neutrophilic airway inflammation and adverse clinical outcomes.Methods: Sputum was collected from 174 stable COPD subjects longitudinally over 12 months. Microbial sampling using culture and qPCR was performed. Spirometry and sputum measures of airway inflammation were assessed.Findings: Sputum was qPCR-positive (>106 copies/mL in 77/152 samples (Haemophilus influenzae [n=52], Moraxella catarrhalis [n=24], Streptococcus pneumoniae [n=19], and Staphylococcus aureus [n=7]. Sputum was culture-positive in 50/174 samples, with 49 out of 50 culture-positive samples having pathogen-specific qPCR bacterial loads >106 copies/mL. Samples that had qPCR copy numbers >106/mL, whether culture-positive or not, had increased sputum neutrophil counts. H. influenzae qPCR copy numbers correlated with sputum neutrophil counts (r=0.37, P<0.001, were repeatable within subjects, and were >106/mL three or more times in 19 patients, eight of whom were repeatedly sputum culture-positive. Persistence, whether

  7. Systemic Air Embolism After CT-guided Lung Biopsy

    Science.gov (United States)

    2017-11-27

    Patients Who Underwent Percutaneous Lung Biopsy Under CT Guidance; Patients Who Presented Systemic Air Embolism After Percutaneous Lung Biopsy Under CT Guidance Depicted at the Time of the Procedure on a Whole Thoracic CT

  8. Normal modified stable processes

    DEFF Research Database (Denmark)

    Barndorff-Nielsen, Ole Eiler; Shephard, N.

    2002-01-01

    Gaussian (NGIG) laws. The wider framework thus established provides, in particular, for added flexibility in the modelling of the dynamics of financial time series, of importance especially as regards OU based stochastic volatility models for equities. In the special case of the tempered stable OU process......This paper discusses two classes of distributions, and stochastic processes derived from them: modified stable (MS) laws and normal modified stable (NMS) laws. This extends corresponding results for the generalised inverse Gaussian (GIG) and generalised hyperbolic (GH) or normal generalised inverse...

  9. Applications of stable isotopes

    International Nuclear Information System (INIS)

    Letolle, R.; Mariotti, A.; Bariac, T.

    1991-06-01

    This report reviews the historical background and the properties of stable isotopes, the methods used for their measurement (mass spectrometry and others), the present technics for isotope enrichment and separation, and at last the various present and foreseeable application (in nuclear energy, physical and chemical research, materials industry and research; tracing in industrial, medical and agronomical tests; the use of natural isotope variations for environmental studies, agronomy, natural resources appraising: water, minerals, energy). Some new possibilities in the use of stable isotope are offered. A last chapter gives the present state and forecast development of stable isotope uses in France and Europe

  10. Liver CT-guided aspirative biopsies

    International Nuclear Information System (INIS)

    Santos, Gilda da Cunha; Carvalho, Leda Viegas de; Chojniak, Rubens; Morini, Sandra Regina

    1996-01-01

    Sixty-eight CT-guided aspirative biopsies of hepatic nodules were performed at A.C. Camargo Hospital, Sao Paulo, Brazil, from 1992 to 1995. The cases were distributed as follow: 44(64.7%) with a positive diagnosis for neoplastic cells, 6(8.8%) with a negative diagnosis, and 14 (20.5%) with insufficient material. Of the positive cases (primary neoplasias and metastases), the cytological diagnosis was achieved in 39 cases. There were 36 cases of carcinoma (7 hepato carcinomas, 18 adenocarcinomas, 1 small cell carcinoma and 10 cases of unspecified differentiation), 2 cases of melanoma and 1 case of melanoma and 1 case of sarcoma. The correlation with histopathological exams showed no false positive cases and concordance between cytological and histopathological diagnosis. The results demonstrate that CT-guided aspirative biopsy of hepatic nodules permits a rapid diagnosis of neoplastic lesions, especially for the evaluation of metastases. (author)

  11. A polarization stabilizer up to 12.6 krad/s with an additional function of stable state of polarization transformation

    International Nuclear Information System (INIS)

    Xiao-Guang, Zhang; Guang-Qing, Fang; Xin-Yuan, Zhao; Wen-Bo, Zhang; Li-Xia, Xi; Qian-Jin, Xiong; Xi-Xiang, Li; Guang-Yong, Zhang

    2010-01-01

    This paper reports on an experiment about a novel method of polarization stabilization. The polarization stabilizer proposed here has an additional function of polarization transformation from any state of polarization into any others. The particle swarm optimization is introduced as a control algorithm in the process of either searching or endless tracking. The tracking speed of the stabilizer is obtained up to 12.6 krad/s by using hardware we have in the laboratory, which means that we can achieve a higher speed practical polarization stabilizer if we have faster hardware. (classical areas of phenomenology)

  12. Breast MR biopsy: Pathological and radiological correlation

    International Nuclear Information System (INIS)

    Dratwa, Chloe; Chopier, Jocelyne; Jalaguier-Coudray, Aurelie; Thomassin-Piana, Jeanne; Gonin, Julie; Antoine, Martine; Trop, Isabelle; Darai, Emile; Thomassin-Naggara, Isabelle

    2016-01-01

    To identify pathological features for sample analysis of magnetic resonance imaging-guided vaccum-assisted breast biopsy (MRIgVaBB) to optimize radio pathological correlation and identify discordant benign result. Databases of two centres were queried to identify MRIgVaBB performed between January 2009 and February 2013. A cohort of 197 women (mean age: 54.5 years (24-77)) with 208 lesions was identified. We retrospectively analyzed all prebiopsy MRI examinations according to the new BI-RADS lexicon, and all biopsy samples to describe the lesion of interest, its interface with the surrounding breast tissue and other associated features. The malignancy rate was 26.0 % (54/208) with an underestimation rate of 15.67 % (5/32). A visible interface at pathology between a biopsied lesion and the surrounding breast tissue was more frequently identified in mass enhancement compared to NME or focus (p = 0.0003). Regional NME was correlated with a high degree of fibrosis (p = 0.001) and the presence of PASH (p = 0.0007). Linear or segmental NME was correlated with the presence of periductal mastitis (p = 0.0003). The description of a visible interface between the target lesion and the surrounding tissue is crucial to confirm the correct targeting of an MR mass or a NME. (orig.)

  13. Acupuncture Induces Time-Dependent Remodelling Brain Network on the Stable Somatosensory First-Ever Stroke Patients: Combining Diffusion Tensor and Functional MR Imaging

    Directory of Open Access Journals (Sweden)

    Lijun Bai

    2014-01-01

    Full Text Available Different treatment interventions induce distinct remodelling of network architecture of entire motor system. Acupuncture has been proved to be of a promising efficacy in motor recovery. However, it is still unclear whether the reorganization of motor-related brain network underlying acupuncture is related with time since stroke and severity of deficit at baseline. The aim of study was to characterize the relation between motor-related brain organization following acupuncture and white matter microstructural changes at an interval of two weeks. We demonstrated that acupuncture induced differential reorganization of motor-related network for stroke patients as time-lapse since stroke. At the baseline, acupuncture can induce the increased functional connectivity between the left primary motor cortex (M1 and the right M1, premotor cortex, supplementary motor area (SMA, thalamus, and cerebellum. After two-week recovery, the increased functional connectivity of the left M1 was more widely distributed and primarily located in the insula, cerebellum, basal ganglia, and SMA. Furthermore, a significant negative relation existed between the FA value in the left M1 at the baseline scanning and node centrality of this region following acupuncture for both baseline and two-week recovery. Our findings may shed a new insight on understanding the reorganization of motor-related theory underlying motor impairments after brain lesions in stroke patients.

  14. Analysing Stable Time Series

    National Research Council Canada - National Science Library

    Adler, Robert

    1997-01-01

    We describe how to take a stable, ARMA, time series through the various stages of model identification, parameter estimation, and diagnostic checking, and accompany the discussion with a goodly number...

  15. False-negative results of breast core needle biopsies – retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, Marek; Kołtun, Urszula; Bobek-Billewicz, Barbara; Chmielik, Ewa; Eksner, Bartosz; Olejnik, Tomasz

    2011-01-01

    Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. 988 core needle breast biopsies were performed at the Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration

  16. False-negative results of breast core needle biopsies - retrospective analysis of 988 biopsies

    International Nuclear Information System (INIS)

    Boba, M.; Koltun, U.; Bobek-Billewicz, B.; Eksner, B.; Olejnik, T.; Chmielik, E.

    2011-01-01

    Background: Breast cancer is the most common malignant neoplasm and the most common cause of death among women. The core needle biopsy is becoming a universal practice in diagnosing breast lesions suspected of malignancy. Unfortunately, breast core needle biopsies also bear the risk of having false-negative results. Material/Methods: 988 core needle breast biopsies were performed at the Maria Sklodowska-Curie Memorial Cancer Center and Institute of Oncology, Gliwice Branch, between 01 March 2006 and 29 February 2008. Malignant lesions were diagnosed in 426/988 (43.12%) cases, atypical hyperplasia in 69/988 (6.98%), and benign lesions in 493/988 (49.90%) cases. Results: Twenty-two out of 988 biopsies (2.23%) were found to be false negative. Histopathological assessment of tissue specimens was repeated in these cases. In 14/22 (64%) cases, the previous diagnosis of a benign lesion was changed. In 8/22 (36%) cases, the diagnosis of a benign lesion was confirmed. False-negative rate was calculated at 2.2%. The rate of false-negative diagnoses resulting from a radiological mistake was estimated at 36%. The rate of false-negative diagnoses, resulting from histopathological assessment, was 64%. False-negative results caused by a radiological error comprised 1.5% of all histopathologically diagnosed cancers and atypias (sensitivity of 98.5%). There were no false-positive results in our material - the specificity of the method was 100%. Conclusions: Histopathological interpretation is a substantial cause of false-negative results of breast core needle biopsy. Thus, in case of a radiological-histopathological divergence, histopathological analysis of biopsy specimens should be repeated. The main radiological causes of false-negative results of breast core needle biopsy are as follows: sampling from an inappropriate site and histopathological non-homogeneity of cancer infiltration. (authors)

  17. Automated gun biopsy of the prostate under ultrasound guide

    International Nuclear Information System (INIS)

    Yang, Ik; Lim, Jae Hoon; Ko, Young Tae; Lee, Dong Ho; Lim, Joo Won

    1994-01-01

    To assess the effectiveness and clinical usefulness of prostate biopsy by automated gun biopsy device under the transrectal ultrasonographic guidance, authors analysed the result of biopsy and the patients status after biopsy procedure. The subjects consisted of 24 patients with prostatic disease. Biopsy instrument was an automated gun biopsy device loaded with an 18 gauze biopsy needle. All the patients were admitted to the hospital. No analgesics was given. All the procedure was performed with the patient in left lateral decubitus. Biopsy was performed at 2-4 different points of the prostate in 22 cases, but recently, six different points were targeted in two patients. Biopsy specimens were sufficient in 21 cases but insufficient in three cases. Histologic examination of biopsy specimens showed that 13 cases were nodular hyperplasia, eight cases were cancerous and three cases were inflammation. There was no clinically significant complication. There was mild to moderate degree of pain in all patients. Tansrectal biopsy of the prostate with an automated gun biopsy device under ultrasonographic guidance is considered relatively easy, handy and useful procedure in patients with prostatic disease. The procedure may be performed on the out patient basis

  18. Nonfocal renal biopsies: adequacy and factors affecting a successful outcome.

    Science.gov (United States)

    Goldstein, Mark A; Atri, Mostafa; O'Malley, Martin; Jacks, Lindsay; John, Rohan; Herzenberg, Andrew; Reich, Heather; Ghai, Sangeet

    2013-01-01

    The purpose of this study was to evaluate factors affecting the success of ultrasound-guided core biopsy of kidneys and determine the optimum number of passes. This retrospective study evaluated 484 nonfocal renal biopsies performed with 18-gauge side-notch biopsy needles. Number of biopsy passes, serum creatinine, body mass index, needle type, transplant age, kidney size, diabetic status, and operator were evaluated as predictors of the number of biopsy passes. Four hundred seventy-four biopsies (338 transplant, 136 native) were included with mean number of passes 2.87 (3.1 native vs 2.78 transplant; P = 0.002). Mean number of glomeruli yielded per pass was 6.9 (7.2 transplant vs 6.1 native; P = 0.0002) with 3 passes adequate for histological diagnosis in 84% of biopsies. Native kidney, increasing serum creatinine level, trainee biopsy operator, and use of a Temno needle were found to be independent predictors of having more than 3 biopsy passes on multivariate analysis. Age, sex, body mass index, diabetic status, and kidney size were not associated with the number of biopsy passes. The success of a nonfocal renal biopsy has many influencing variables, and in the absence of an on-site electron microscopy technologist to immediately evaluate biopsy samples, 3 passes with an 18-gauge needle would be adequate in 84% of kidneys to achieve a histological diagnosis, with 2 passes needed for transplant kidneys to meet the Banff 97 criteria.

  19. 21 CFR 876.1075 - Gastroenterology-urology biopsy instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastroenterology-urology biopsy instrument. 876... SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1075 Gastroenterology-urology biopsy instrument. (a) Identification. A gastroenterology-urology biopsy instrument is a...

  20. Pleural biopsy for indeterminate cases of pleural effusion | Ukadike ...

    African Journals Online (AJOL)

    Materials and Methods: This is a retrospective study of all consecutive cases of pleural biopsies done for indeterminate cause of pleural effusion in the University of Benin Teaching Hospital from December 2008 to May 2010, a total of 18months. Blind pleural biopsy was carried out using the Abram's Pleural Biopsy Needle.

  1. Short interval follow-up after a benign concordant MR-guided vacuum assisted breast biopsy - is it worthwhile?

    Energy Technology Data Exchange (ETDEWEB)

    Shaylor, Sara D.; Melsaether, Amy N.; Gupta, Avani; Babb, James; Moy, Linda [NYU School of Medicine, Department of Radiology, New York, NY (United States); Heller, Samantha L. [St. George' s Healthcare Trust, Department of Radiology, London (United Kingdom); Gupta, Dipti [Northwestern Memorial Hospital, Breast and Women' s Imaging Center, Chicago, IL (United States)

    2014-06-15

    To determine the utility of short-interval follow-up after benign concordant MRI-guided breast biopsy. Institutional review board approved, retrospective review of consecutive biopsies performed over 3 years (2007-10) yielded 170 women with 188 lesions that were considered benign concordant. Indication for original study, biopsy results, follow-up recommendations, compliance and outcomes of subsequent MRI and mammography examinations were reviewed. The most common indication for breast MRI was high-risk screening 119/170 (70 %). Overall, 59 % of lesions (113/188) had follow-up MRI. Of those lesions (n = 113), 43 % (49/113) presented within 7 months, 26 % (29/113) presented within 8-13 months, 11.5 % (13/113) presented within 14-22 months, and 19 % (22/113) presented after 23 months. At initial follow-up, 37 % of lesions were stable and 61 % were decreased in size. Three lesions were recommended for excision based on follow-up imaging with one malignancy diagnosed 2 years following biopsy. One additional patient had MRI-detected bilateral cancers remote from the biopsy site 3 years after biopsy. Overall cancer yield of lesions with follow-up MRI was 0.9 % (1/113); no cancers were detected at 6 months. Our data suggests that 6-month follow-up may not be required and that annual screening MRI would be acceptable to maintain a reasonable cancer detection rate. (orig.)

  2. Short interval follow-up after a benign concordant MR-guided vacuum assisted breast biopsy - is it worthwhile?

    International Nuclear Information System (INIS)

    Shaylor, Sara D.; Melsaether, Amy N.; Gupta, Avani; Babb, James; Moy, Linda; Heller, Samantha L.; Gupta, Dipti

    2014-01-01

    To determine the utility of short-interval follow-up after benign concordant MRI-guided breast biopsy. Institutional review board approved, retrospective review of consecutive biopsies performed over 3 years (2007-10) yielded 170 women with 188 lesions that were considered benign concordant. Indication for original study, biopsy results, follow-up recommendations, compliance and outcomes of subsequent MRI and mammography examinations were reviewed. The most common indication for breast MRI was high-risk screening 119/170 (70 %). Overall, 59 % of lesions (113/188) had follow-up MRI. Of those lesions (n = 113), 43 % (49/113) presented within 7 months, 26 % (29/113) presented within 8-13 months, 11.5 % (13/113) presented within 14-22 months, and 19 % (22/113) presented after 23 months. At initial follow-up, 37 % of lesions were stable and 61 % were decreased in size. Three lesions were recommended for excision based on follow-up imaging with one malignancy diagnosed 2 years following biopsy. One additional patient had MRI-detected bilateral cancers remote from the biopsy site 3 years after biopsy. Overall cancer yield of lesions with follow-up MRI was 0.9 % (1/113); no cancers were detected at 6 months. Our data suggests that 6-month follow-up may not be required and that annual screening MRI would be acceptable to maintain a reasonable cancer detection rate. (orig.)

  3. 13C- and 15N-labelled non-biogenic compounds used as stable isotope drugs for human liver function tests

    International Nuclear Information System (INIS)

    Krumbiegel, P.

    1989-01-01

    As a result of liver diseases, the elimination of certain drugs is retarded. After labelling a suitable drug with 13 C, the 13 CO 2 elimination rate serves as a liver function parameter. Current contributions to the 13 CO 2 breath test method are reviewed and related to the 14 CO 2 breath test proposals. In spite of several advantages of 13 C-labelled agents, some dissatisfaction has remained with the tests, especially at using them with infants. It is the necessity of face masks and the uncertainty to consider endogeneous CO 2 contributions diluting the exhaled 13 CO 2 . The problems are avoided if the other molecule site of the drug is labelled which is known to be eliminated via urine. With 15 N as a tracer, a suitable urine test using [ 15 N]-methacetin as agent has been proposed and put into practice. (author)

  4. Excitation functions and isotopic effects in (n, p) reactions for stable nickel isotopes from reaction threshold to 20 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Lalremruata, B. [Department of Physics, University of Pune, Ganeshkhind, Pune-411007, Maharashtra (India)], E-mail: marema@physics.unipune.ernet.in; Ganesan, S. [Reactor Physics Design Division, BARC, Mumbai 58 (India); Bhoraskar, V.N. [Department of Physics, University of Pune, Ganeshkhind, Pune-411007, Maharashtra (India)], E-mail: vnb@physics.unipune.ernet; Dhole, S.D. [Department of Physics, University of Pune, Ganeshkhind, Pune-411007, Maharashtra (India)], E-mail: sanjay@physics.unipune.ernet.in

    2009-05-01

    The excitation function for (n, p) reactions from reaction threshold to 20 MeV on five nickel isotopes viz; {sup 58}Ni, {sup 60}Ni, {sup 61}Ni, {sup 62}Ni and {sup 64}Ni were calculated using Talys-1.0 nuclear model code involving the fixed set of global parameters. A good agreement between the calculated and measured data is obtained with minimum effort on parameter fitting and only one free parameter called 'Shell damping factor'. This is of importance to the validation of nuclear model approaches with increased predictive power. The systematic decrease in (n, p) cross-sections with increasing neutron number in reactions induced by neutrons on isotopes of nickel is explained in terms of the proton separation energy and the pre-equilibrium model. The compound nucleus and pre-equilibrium reaction mechanism as well as the isotopic effects were also studied.

  5. The spacing between adjacent binding sites in the family of repeats affects the functions of Epstein-Barr nuclear antigen 1 in transcription activation and stable plasmid maintenance.

    Science.gov (United States)

    Hebner, Christy; Lasanen, Julie; Battle, Scott; Aiyar, Ashok

    2003-07-05

    Epstein-Barr virus (EBV) and the closely related Herpesvirus papio (HVP) are stably replicated as episomes in proliferating latently infected cells. Maintenance and partitioning of these viral plasmids requires a viral sequence in cis, termed the family of repeats (FR), that is bound by a viral protein, Epstein-Barr nuclear antigen 1 (EBNA1). Upon binding FR, EBNA1 maintains viral genomes in proliferating cells and activates transcription from viral promoters required for immortalization. FR from either virus encodes multiple binding sites for the viral maintenance protein, EBNA1, with the FR from the prototypic B95-8 strain of EBV containing 20 binding sites, and FR from HVP containing 8 binding sites. In addition to differences in the number of EBNA1-binding sites, adjacent binding sites in the EBV FR are typically separated by 14 base pairs (bp), but are separated by 10 bp in HVP. We tested whether the number of binding sites, as well as the distance between adjacent binding sites, affects the function of EBNA1 in transcription activation or plasmid maintenance. Our results indicate that EBNA1 activates transcription more efficiently when adjacent binding sites are separated by 10 bp, the spacing observed in HVP. In contrast, using two separate assays, we demonstrate that plasmid maintenance is greatly augmented when adjacent EBNA1-binding sites are separated by 14 bp, and therefore, presumably lie on the same face of the DNA double helix. These results provide indication that the functions of EBNA1 in transcription activation and plasmid maintenance are separable.

  6. The spacing between adjacent binding sites in the family of repeats affects the functions of Epstein-Barr nuclear antigen 1 in transcription activation and stable plasmid maintenance

    International Nuclear Information System (INIS)

    Hebner, Christy; Lasanen, Julie; Battle, Scott; Aiyar, Ashok

    2003-01-01

    Epstein-Barr virus (EBV) and the closely related Herpesvirus papio (HVP) are stably replicated as episomes in proliferating latently infected cells. Maintenance and partitioning of these viral plasmids requires a viral sequence in cis, termed the family of repeats (FR), that is bound by a viral protein, Epstein-Barr nuclear antigen 1 (EBNA1). Upon binding FR, EBNA1 maintains viral genomes in proliferating cells and activates transcription from viral promoters required for immortalization. FR from either virus encodes multiple binding sites for the viral maintenance protein, EBNA1, with the FR from the prototypic B95-8 strain of EBV containing 20 binding sites, and FR from HVP containing 8 binding sites. In addition to differences in the number of EBNA1-binding sites, adjacent binding sites in the EBV FR are typically separated by 14 base pairs (bp), but are separated by 10 bp in HVP. We tested whether the number of binding sites, as well as the distance between adjacent binding sites, affects the function of EBNA1 in transcription activation or plasmid maintenance. Our results indicate that EBNA1 activates transcription more efficiently when adjacent binding sites are separated by 10 bp, the spacing observed in HVP. In contrast, using two separate assays, we demonstrate that plasmid maintenance is greatly augmented when adjacent EBNA1-binding sites are separated by 14 bp, and therefore, presumably lie on the same face of the DNA double helix. These results provide indication that the functions of EBNA1 in transcription activation and plasmid maintenance are separable

  7. Inhibition of muscle-specific gene expression by Id3: requirement of the C-terminal region of the protein for stable expression and function.

    Science.gov (United States)

    Chen, B; Han, B H; Sun, X H; Lim, R W

    1997-01-15

    We have examined the role of an Id-like protein, Id3 (also known as HLH462), in the regulation of muscle-specific gene expression. Id proteins are believed to block expression of muscle-specific genes by preventing the dimerization between ubiquitous bHLH proteins (E proteins) and myogenic bHLH proteins such as MyoD. Consistent with its putative role as an inhibitor of differentiation, Id3 mRNA was detected in proliferating skeletal muscle cells, was further induced by basic fibroblast growth factor (bFGF) and was down-regulated in differentiated muscle cultures. Overexpression of Id3 efficiently inhibited the MyoD-mediated activation of the muscle-specific creatine kinase (MCK) reporter gene. Deletion analysis indicated that the C-terminal 15 amino acids of Id3 are critical for the full inhibitory activity while deleting up to 42 residues from the C-terminus of the related protein, Id2, did not affect its ability to inhibit the MCK reporter gene. Chimeric protein containing the N-terminal region of Id3 and the C-terminus of Id2 was also non-functional in transfected cells. In contrast, wild-type Id3, the C-terminal mutants, and the Id3/Id2 chimera could all interact with the E-protein E47in vitro. Additional studies indicated that truncation of the Id3 C-terminus might have adversely affected the expression level of the mutant proteins but the Id3/Id2 chimera was stably expressed. Taken together, our results revealed a more complex requirement for the expression and proper function of the Id family proteins than was hitherto expected.

  8. Effects of Pycnogenol on endothelial function in patients with stable coronary artery disease: a double-blind, randomized, placebo-controlled, cross-over study.

    Science.gov (United States)

    Enseleit, Frank; Sudano, Isabella; Périat, Daniel; Winnik, Stephan; Wolfrum, Mathias; Flammer, Andreas J; Fröhlich, Georg M; Kaiser, Priska; Hirt, Astrid; Haile, Sarah R; Krasniqi, Nazmi; Matter, Christian M; Uhlenhut, Klaus; Högger, Petra; Neidhart, Michel; Lüscher, Thomas F; Ruschitzka, Frank; Noll, Georg

    2012-07-01

    Extracts from pine tree bark containing a variety of flavonoids have been used in traditional medicine. Pycnogenol is a proprietary bark extract of the French maritime pine tree (Pinus pinaster ssp. atlantica) that exerts antioxidative, anti-inflammatory, and anti-platelet effects. However, the effects of Pycnogenol on endothelial dysfunction, a precursor of atherosclerosis and cardiovascular events, remain still elusive. Twenty-three patients with coronary artery disease (CAD) completed this randomized, double-blind, placebo-controlled cross-over study. Patients received Pycnogenol (200 mg/day) for 8 weeks followed by placebo or vice versa on top of standard cardiovascular therapy. Between the two treatment periods, a 2-week washout period was scheduled. At baseline and after each treatment period, endothelial function, non-invasively assessed by flow-mediated dilatation (FMD) of the brachial artery using high-resolution ultrasound, biomarkers of oxidative stress and inflammation, platelet adhesion, and 24 h blood pressure monitoring were evaluated. In CAD patients, Pycnogenol treatment was associated with an improvement of FMD from 5.3 ± 2.6 to 7.0 ± 3.1 (P effect 2.75; 95% confidence interval (CI): 1.75, 3.75, P < 0.0001]. 15-F(2t)-Isoprostane, an index of oxidative stress, significantly decreased from 0.71 ± 0.09 to 0.66 ± 0.13 after Pycnogenol treatment, while no change was observed in the placebo group (mean difference 0.06 pg/mL with an associated 95% CI (0.01, 0.11), P = 0.012]. Inflammation markers, platelet adhesion, and blood pressure did not change after treatment with Pycnogenol or placebo. This study provides the first evidence that the antioxidant Pycnogenol improves endothelial function in patients with CAD by reducing oxidative stress.

  9. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    International Nuclear Information System (INIS)

    Hacker, M.; Hack, N.; Tiling, R.; Jakobs, T.; Nikolaou, K.; Becker, C.; Ziegler, F. von; Knez, A.; Koenig, A.; Klauss, V.

    2007-01-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 ± 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  10. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, M.; Hack, N.; Tiling, R. [Klinikum Grosshadern (Germany). Dept. of Nuclear Medicine; Jakobs, T.; Nikolaou, K.; Becker, C. [Klinikum Grosshadern (Germany). Dept. of Clinical Radiology; Ziegler, F. von; Knez, A. [Klinikum Grosshadern (Germany). Dept. of Cardiology; Koenig, A.; Klauss, V. [Medizinische Poliklinik-Innenstadt, Univ. of Munich (Germany). Dept. of Cardiology

    2007-07-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting ''obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 {+-} 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  11. Unguided bronchoscopic biopsy: Does yield increase with operator experience

    Directory of Open Access Journals (Sweden)

    Tyagi Rahul

    2017-08-01

    Full Text Available Background Bronchoscopic Forceps biopsy (Endobronchial Biopsy (EBB and Trans Bronchial Lung Biopsy (TBLB are commonly performed for diagnosis in patients with endobronchial abnormalities or diffuse parenchymal involvement. As the operator gains experience his yield of various diagnostic bronchoscopic biopsies is expected to increase, however, no studies on the subject are available in literature. Aims To determine the effect of on- job experience on the yield of unguided bronchoscopic biopsies. Methods A total of 244 bronchoscopies were performed between Oct 2013 and Oct 2016. A retrospective analysis of all these bronchoscopies was undertaken. All patients who underwent biopsy were included in the study. Patients were divided into two groups with first group (Group A comprising of biopsies done between Oct 2013 to Apr 2015 and second group comprising biopsies done between May 2015 to Oct 2016 (Group B. The diagnostic yield in two groups was compared. Results Total 71 bronchoscopic biopsies were performed during Oct 2013 to Oct 2016. 36 patients were included in group A and 35 patients were included in group B. The groups were matched in demographic profile, clinical diagnosis, bronchoscopic findings and type of biopsy undertaken. The biopsy was diagnostic in 31 patient (43.6 per cent and nondiagnostic in 33 patients (46.4 per cent. There were 15 diagnostic biopsies in group A and 16 diagnostic biopsies in group B. The difference in the diagnostic biopsies between the two groups was not significant. Conclusion There was no significant impact of on job experience on diagnostic yield of biopsies. This may be due to adequate exposure during training leading to a diagnostic plateau being reached.

  12. Migration of Gelfoam to the gallbladder after liver biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Riddle, Chris [The Hospital for Sick Children, Image Guided Therapy, Department of Diagnostic Imaging, Toronto (Canada); Dalhousie University, School of Medicine, Halifax (Canada); Ahmed, Bilal [University of Toronto School of Medicine, Toronto (Canada); Doyle, John [The Hospital for Sick Children, Department of Hematology/Oncology, Toronto (Canada); Connolly, Bairbre L. [The Hospital for Sick Children, Image Guided Therapy, Department of Diagnostic Imaging, Toronto (Canada)

    2008-07-15

    Liver biopsy is a common procedure, with an inherent risk of bleeding. There are different ways to help avoid hemorrhage, including biopsy through a transjugular venous route or embolization of the tract with liquid or solid materials. We describe an image-guided percutaneous core needle liver biopsy with tract embolization using thick Gelfoam slurry in a pediatric oncology patient. Imaging studies acquired after the biopsy indicated that the Gelfoam mixture had likely migrated to the gallbladder and common bile duct. We report this rare occurrence with its striking imaging in order to make those performing biopsies aware of this possibility. (orig.)

  13. Image-guided breast biopsy: state-of-the-art

    Energy Technology Data Exchange (ETDEWEB)

    O' Flynn, E.A.M., E-mail: lizoflynn@doctors.org.u [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom); Wilson, A.R.M.; Michell, M.J. [South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS (United Kingdom)

    2010-04-15

    Percutaneous image-guided breast biopsy is widely practised to evaluate predominantly non-palpable breast lesions. There has been steady development in percutaneous biopsy techniques. Fine-needle aspiration cytology was the original method of sampling, followed in the early 1990s by large core needle biopsy. The accuracy of both has been improved by ultrasound and stereotactic guidance. Larger bore vacuum-assisted biopsy devices became available in the late 1990s and are now commonplace in most breast units. We review the different types of breast biopsy devices currently available together with various localization techniques used, focusing on their advantages, limitations and current controversial clinical management issues.

  14. Management implications from routine needle biopsy of hyperfunctioning thyroid nodules.

    Science.gov (United States)

    Walfish, P G; Strawbridge, H T; Rosen, I B

    1985-12-01

    To evaluate the diagnostic and treatment consequences of using a routine needle biopsy procedure on all thyroid nodules without a radioisotopic scintigraphic study, 12 patients with documented hyperfunctioning thyroid nodules were retrospectively evaluated regarding the physical and cytologic observations obtained after a fine-needle (22 to 27-gauge) aspiration biopsy (FNB) procedure. Among the seven solid lesions, features of marked cellularity and nuclear pleomorphism were present in three and moderate sheets of epithelium in four raising the suspicion of underlying malignancy, while five mixed (cystic and solid) lesions were larger than 3 cm, hemorrhagic, and recurrent, with two having detectable sheets of epithelium. Evidence for concomitant lymphocytic thyroiditis was seen in five of 12 (42%) patients, and nine had positive serum antithyroid antibody titers as well. In conclusion, total reliance on FNB without scintigraphy could lead to operations on hyperfunctioning thyroid adenomas for suspected malignancy, of whom the vast majority would be benign, and could expose some unprepared patients with thyrotoxicosis to surgical morbidity. Routine thyroid hormone suppression therapy for apparently benign inflammatory or cystic degenerative lesions could also induce hyperthyroidism in patients with hyperfunctional or autonomous (nonsuppressible) nodules. When using an initial FNB approach, the need for thyroid function studies and scintigraphy before undertaking surgery or thyroid hormone feeding, as well as the consequences of omitting such studies, should be considered.

  15. Histological Spectrum of Idiopathic Noncirrhotic Portal Hypertension in Liver Biopsies From Dialysis Patients.

    Science.gov (United States)

    Lee, Hwajeong; Ainechi, Sanaz; Singh, Mandeep; Ells, Peter F; Sheehan, Christine E; Lin, Jingmei

    2015-09-01

    Liver biopsy is performed for various indications in dialysis patients. Being a less-common subset, the hepatic pathology in renal dialysis is not well documented. Idiopathic noncirrhotic portal hypertension (INCPH) is a clinical entity associated with unexplained portal hypertension and/or a spectrum of histopathological vascular changes in the liver. After encountering INCPH and vascular changes of INCPH in 2 renal dialysis patients, we sought to further investigate this noteworthy association. A random search for patients on hemodialysis or peritoneal dialysis with liver biopsy was performed. Hematoxylin and eosin, reticulin, trichrome, and CK7 stains were performed on formalin-fixed, paraffin-embedded tissue sections. Histopathological features were reviewed, and the results were correlated with clinical findings. In all, 13 liver biopsies were retrieved. The mean cumulative duration of dialysis was 50 months (range = 17 months to 11 years). All patients had multiple comorbidities. Indications for biopsy were a combination of abnormal liver function tests (6), portal hypertension (4), ascites (3), and possible cirrhosis (3). Two patients with portal hypertension underwent multiple liver biopsies for diagnostic purposes. All (100%) biopsies showed some histological features of INCPH, including narrowed portal venous lumen (9), increased portal vascular channels (8), shunt vessels (3), dilated sinusoids (9), regenerative nodule (5), and features of venous outflow obstruction (3). No cirrhosis was identified. Liver biopsies from patients on dialysis demonstrate histopathological vascular changes of INCPH. Some (31%) patients present with portal hypertension without cirrhosis. The histological changes may be reflective of underlying risk factors for INCPH in this group. © The Author(s) 2015.

  16. Multiple biopsy probe sampling enabled minimally invasive electrical impedance tomography

    International Nuclear Information System (INIS)

    Shini, Mohanad; Rubinsky, Boris

    2008-01-01

    Biopsies are a reliable method for examining tissues and organs inside the body, in particular for detection of tumors. However, a single biopsy produces only limited information on the site from which it is taken. Therefore, tumor detection now employs multiple biopsy samplings to examine larger volumes of tissue. Nevertheless, even with multiple biopsies, the information remains discrete, while the costs of biopsy increase. Here we propose and evaluate the feasibility of using minimally invasive medical imaging as a means to overcome the limitations of discrete biopsy sampling. The minimally invasive medical imaging technique employs the biopsy probe as electrodes for measurements of electrical impedance tomography relevant data during each biopsy sampling. The data from multiple samplings are combined and used to produce an EIT image of the tissue. Two- and three-dimensional mathematical simulations confirm that the minimally invasive medical imaging technique can produce electrical impedance tomography images of the tissues between the biopsy probe insertion sites. We show that these images can detect tumors that would be missed with multiple biopsy samplings only, and that the technique may facilitate the detection of tumors with fewer biopsies, thereby reducing the cost of cancer detection

  17. Accuracy of percutaneous lung biopsy for invasive pulmonary aspergillosis

    Energy Technology Data Exchange (ETDEWEB)

    Hoffer, F.A. [Dept. of Diagnostic Imaging, St. Jude Children' s Research Hospital, Memphis, TN (United States); Gow, K.; Davidoff, A. [Dept. of Surgery, St. Jude Children' s Research Hospital, Memphis, TN (United States); Flynn, P.M. [Dept. of Infectious Diseases, St. Jude Children' s Research Hospital, Memphis, TN (United States)

    2001-03-01

    Background. Invasive pulmonary aspergillosis is fulminant and often fatal in immunosuppressed patients. Percutaneous biopsy may select patients who could benefit from surgical resection. Objective. We sought to determine the accuracy of percutaneous biopsy for pediatric invasive pulmonary aspergillosis. Materials and methods. We retrospectively reviewed 28 imaging-guided percutaneous biopsies of the lungs of 24 children with suspected pulmonary aspergillosis. Twenty-two were being treated for malignancy and two for congenital immunodeficiency; 15 had received bone-marrow transplants. The accuracy of the percutaneous lung biopsy was determined by subsequent surgical resection, autopsy, or clinical course. Results. Histopathological studies showed ten biopsy specimens with septate hyphae, indicating a mold, and seven with Aspergillus flavus colonies in culture. The remaining 18 biopsies revealed no fungi. No patient had progressive aspergillosis after negative biopsy. Invasive pulmonary mold was detected by percutaneous biopsy with 100 % (10/10) sensitivity and 100 % (18/18) specificity. Percutaneous biopsy results influenced the surgical decision in 86 % (24 of 28) of the cases. Bleeding complicated the biopsy in 46 % (13/28) and hastened one death. Conclusion. Percutaneous biopsy of the lung is an accurate technique for the diagnosis of invasive pulmonary aspergillosis and correctly determines which immunosuppressed pediatric patients would benefit from therapeutic pulmonary resection. (orig.)

  18. Accuracy of percutaneous lung biopsy for invasive pulmonary aspergillosis

    International Nuclear Information System (INIS)

    Hoffer, F.A.; Gow, K.; Davidoff, A.; Flynn, P.M.

    2001-01-01

    Background. Invasive pulmonary aspergillosis is fulminant and often fatal in immunosuppressed patients. Percutaneous biopsy may select patients who could benefit from surgical resection. Objective. We sought to determine the accuracy of percutaneous biopsy for pediatric invasive pulmonary aspergillosis. Materials and methods. We retrospectively reviewed 28 imaging-guided percutaneous biopsies of the lungs of 24 children with suspected pulmonary aspergillosis. Twenty-two were being treated for malignancy and two for congenital immunodeficiency; 15 had received bone-marrow transplants. The accuracy of the percutaneous lung biopsy was determined by subsequent surgical resection, autopsy, or clinical course. Results. Histopathological studies showed ten biopsy specimens with septate hyphae, indicating a mold, and seven with Aspergillus flavus colonies in culture. The remaining 18 biopsies revealed no fungi. No patient had progressive aspergillosis after negative biopsy. Invasive pulmonary mold was detected by percutaneous biopsy with 100 % (10/10) sensitivity and 100 % (18/18) specificity. Percutaneous biopsy results influenced the surgical decision in 86 % (24 of 28) of the cases. Bleeding complicated the biopsy in 46 % (13/28) and hastened one death. Conclusion. Percutaneous biopsy of the lung is an accurate technique for the diagnosis of invasive pulmonary aspergillosis and correctly determines which immunosuppressed pediatric patients would benefit from therapeutic pulmonary resection. (orig.)

  19. Transrectal ultrasound and needle biopsy of the prostate

    Directory of Open Access Journals (Sweden)

    Tomaž Smrkolj

    2016-01-01

    Full Text Available In the last 25 years widespread use of prostatic specific antigen caused a stage migration of prostate cancer towards localized disease at diagnosis, which resulted in transrectal ultrasound biopsy to become standard in clinical practice. Transrectal ultrasound examination of the prostate is used to diagnose benign prostatic diseases, e.g. benign prostatic enlargement, prostatitis, prostatic and seminal vesicle cysts. It is also important in detection of obstructive causes of male infertility. Transrectal ultrasound examination is performed most often in needle biopsy for prostate cancer diagnosis. Besides guiding systematic tissue core biopsy, characteristic ultrasound changes enables target biopsies of suspect areas. The article describes indications, contraindications, antibiotic prophylaxis, various biopsy templates and complications of the needle biopsy. Experience with transrectal ultrasound guided biopsy at Department of urology at University medical center in Ljubljana is presented.

  20. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  1. Diagnosis of prostate cancer with needle biopsy: should all cases be biopsied before treatment?

    Science.gov (United States)

    Oranusi, C K; Ugezu, A I; Nwofor, Ame

    2012-01-01

    The triad of digital rectal examination (DRE), serum prostate specific antigen, and transrectal ultrasound-guided prostate biopsy is used in the detection of prostate cancer (PCa). It is recommended that all cases of PCa should be diagnosed with needle biopsy before treatment. The exclusion criteria for those that may not be suitable have not yet been defined. We reviewed all the patients diagnosed with PCa at the Nnamdi Azikiwe University Teaching Hospital Nnewi, Southeast, Nigeria, from January 2007 to December 2010. Relevant biodata and method of diagnosis of PCa before treatment were reviewed. A total of 133 patients had bilateral orchidectomy over the period. 120 (90.2%) had their diagnosis confirmed by needle biopsy before bilateral orchidectomy (category 1), while 13 (9.8%) had bilateral orchidectomy before diagnosis was confirmed. The method of diagnosis for category 1 patients was with lower urinary tract symptoms (LUTS), abnormal DRE findings, elevated prostate-specific antigen (PSA), and transrectal needle biopsy. For category 11 patients, diagnosis of PCa was suspected based on LUTS, abnormal DRE findings, and elevated PSA. Of this number, 11 (84.6%) had, in addition, sudden onset paraplegia at presentation, while 2 (15.4%) had severe uncontrolled hematuria at presentation. All the patients in both categories had needle biopsy confirmation of their disease. The sensitivity of PSA was 99.2%. Needle biopsy of the prostate is the preferred method for the diagnosis of PCa in most cases before treatment is undertaken. There are valid reasons why all PCas will not be diagnosed in this fashion. Elevated PSA when combined with an abnormal DRE finding increases the predictive value for cancer. In areas where pathologists are lacking, abnormal DRE and elevated PSA results can be a guide to proceed to treatment especially, where there is severe compromise of patients' quality of life due to symptoms of advanced PCa while awaiting confirmation.

  2. Calcium stable isotope geochemistry

    Energy Technology Data Exchange (ETDEWEB)

    Gausonne, Nikolaus [Muenster Univ. (Germany). Inst. fuer Mineralogie; Schmitt, Anne-Desiree [Strasbourg Univ. (France). LHyGeS/EOST; Heuser, Alexander [Bonn Univ. (Germany). Steinmann-Inst. fuer Geologie, Mineralogie und Palaeontologie; Wombacher, Frank [Koeln Univ. (Germany). Inst. fuer Geologie und Mineralogie; Dietzel, Martin [Technische Univ. Graz (Austria). Inst. fuer Angewandte Geowissenschaften; Tipper, Edward [Cambridge Univ. (United Kingdom). Dept. of Earth Sciences; Schiller, Martin [Copenhagen Univ. (Denmark). Natural History Museum of Denmark

    2016-08-01

    This book provides an overview of the fundamentals and reference values for Ca stable isotope research, as well as current analytical methodologies including detailed instructions for sample preparation and isotope analysis. As such, it introduces readers to the different fields of application, including low-temperature mineral precipitation and biomineralisation, Earth surface processes and global cycling, high-temperature processes and cosmochemistry, and lastly human studies and biomedical applications. The current state of the art in these major areas is discussed, and open questions and possible future directions are identified. In terms of its depth and coverage, the current work extends and complements the previous reviews of Ca stable isotope geochemistry, addressing the needs of graduate students and advanced researchers who want to familiarize themselves with Ca stable isotope research.

  3. Calcium stable isotope geochemistry

    International Nuclear Information System (INIS)

    Gausonne, Nikolaus; Schmitt, Anne-Desiree; Heuser, Alexander; Wombacher, Frank; Dietzel, Martin; Tipper, Edward; Schiller, Martin

    2016-01-01

    This book provides an overview of the fundamentals and reference values for Ca stable isotope research, as well as current analytical methodologies including detailed instructions for sample preparation and isotope analysis. As such, it introduces readers to the different fields of application, including low-temperature mineral precipitation and biomineralisation, Earth surface processes and global cycling, high-temperature processes and cosmochemistry, and lastly human studies and biomedical applications. The current state of the art in these major areas is discussed, and open questions and possible future directions are identified. In terms of its depth and coverage, the current work extends and complements the previous reviews of Ca stable isotope geochemistry, addressing the needs of graduate students and advanced researchers who want to familiarize themselves with Ca stable isotope research.

  4. The biopsy of the boar testes using ultrasonographic examination

    Directory of Open Access Journals (Sweden)

    Laima Liepa

    2014-03-01

    Full Text Available The biopsy of live animal testes is an important clinical manipulation to control spermatogenesis and reproductive system pathologies. The aim was to develop a method of boar testes biopsy using a biopsy gun with ultrasound guidance and to investigate the influence of this procedure on the boar testes parenchyma and quality of ejaculate. The biopsy was carried out in six 8-month-old boars. Fourteen days prior to and 21 days after biopsy, the quality of ejaculate was examined (weight of ejaculate; concentration and motility of spermatozoa with a seven-day intervals. Ultrasound images of the testes parenchyma were recorded three times: directly before and 15 minutes after the biopsy, then 21 days after the procedure. The testes biopsies of generally anesthetized boars were performed with the biopsy gun for needle biopsy with a 12cm long, disposable 16-gauge needle 1.8mm in diameter (Vitesse through 1cm skin incision in the depth of 1.2-1.6cm of parenchyma. Fifteen minutes after the biopsy, macroscopic injures of the parenchyma of all the boar testes were not detected in the ultrasound image. Twenty one days after biopsy, the hyperechogenic line 0.1-0.2cm in diameter was seen in the testes parenchyma of six boars in the depth of 1.2-1.6cm. The biopsy of boar testes did not influence the quality of boars ejaculate. The ultrasonographic examination of boar testicles before the biopsy reduced possibilities to traumatize large blood vessels of the testes. A perfect boar testicular biopsy was easy to perform using ultrasonographic examination in the pigsty conditions.

  5. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    International Nuclear Information System (INIS)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I.; Halpern, Elkan F.; Springfield, Dempsey S.

    2015-01-01

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ 2 test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a benign

  6. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute for Technology Assessment, Department of Radiology, Boston, MA (United States); Springfield, Dempsey S. [Massachusetts General Hospital, Department of Orthopedics, Boston, MA (United States)

    2015-12-15

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ{sup 2} test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a

  7. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...

  8. Analysis of costs of transrectal prostate biopsy.

    Science.gov (United States)

    Fandella, Andrea

    2011-01-01

    Literature reports mortality and morbidity data from prostatic carcinoma which permit a better use of some routine diagnostic tools such as transrectal ultrasound-guided biopsy. The aim of this work is to quantify the overall cost of transrectal ultrasound biopsy of the prostate (TRUSB) and to assess the economic impact of current procedures for diagnosing prostatic carcinoma. The total cost of TRUSB was calculated with reference to 247 procedures performed in 2008. The following cost factors were evaluated: personnel, materials, maintenance/depreciation of the equipment, energy consumption, and hospital overheads. A literature review was also carried out to check if our extrapolated costs corresponded to those of other authors worldwide, and to consider them in the wider framework of the economic effectiveness of strategies for early diagnosis of cancer of the prostate. The overall cost of TRUSB (8 samples) was EUR 249,000, obtained by adding together the costs of: personnel (EUR 160,000); materials (EUR 59,000); equipment maintenance and depreciation (EUR 12,400); energy consumption (EUR0,1); hospital overheads (EUR 17,500). With extended or saturation biopsies the cost increases for the more time needed by pathologists and can be calculated as EUR 300,000. The literature review points out TRUSB as an invasive tool for diagnosing prostatic carcinoma, clinically and economically controversial. Post-mortem data report the presence of cancer cells in the prostate of 50% of 70-year-old men, while extrapolations calculate a morbidity rate from prostatic carcinoma in 9.5% of 50-year-old men. It is therefore obvious that randomized prostatic biopsies, methods apart, have a good probability of being positive. This probability varies with the patient's age, the level of prostate specific antigen (PSA), the density of PSA/cm3 of prostate volume (PSAD), and the detection by digital exploration and/or positive transrectal ultrasound. CONCLUSIONS. Despite the severe

  9. A histopathological score on baseline biopsies from elderly donors predicts outcome 1 year after renal transplantation

    DEFF Research Database (Denmark)

    Toft, Birgitte G; Federspiel, Birgitte H; Sørensen, Søren S

    2012-01-01

    wall thickness of arteries and/or arterioles. Nineteen renal baseline biopsies from 15 donors (age: 64 ± 10 years) were included and following consensus the histopathological score was 4.3 ± 2.1 (intraclass correlation coefficient: 0.81; confidence interval: 0.66-0.92). The donor organs were used......Kidneys from elderly deceased patients and otherwise marginal donors may be considered for transplantation and a pretransplantation histopathological score for prediction of postoperative outcome is warranted. In a retrospective design, 29 baseline renal needle biopsies from elderly deceased donors...... Danish donors a histopathological score on baseline renal needle biopsies, with at least ten glomeruli and one artery present, predicts graft function 1 year after transplantation....

  10. Stable isotope studies

    International Nuclear Information System (INIS)

    Ishida, T.

    1992-01-01

    The research has been in four general areas: (1) correlation of isotope effects with molecular forces and molecular structures, (2) correlation of zero-point energy and its isotope effects with molecular structure and molecular forces, (3) vapor pressure isotope effects, and (4) fractionation of stable isotopes. 73 refs, 38 figs, 29 tabs

  11. Interactive Stable Ray Tracing

    DEFF Research Database (Denmark)

    Dal Corso, Alessandro; Salvi, Marco; Kolb, Craig

    2017-01-01

    Interactive ray tracing applications running on commodity hardware can suffer from objectionable temporal artifacts due to a low sample count. We introduce stable ray tracing, a technique that improves temporal stability without the over-blurring and ghosting artifacts typical of temporal post-pr...

  12. The Stable Concordance Genus

    OpenAIRE

    Kearney, M. Kate

    2013-01-01

    The concordance genus of a knot is the least genus of any knot in its concordance class. Although difficult to compute, it is a useful invariant that highlights the distinction between the three-genus and four-genus. In this paper we define and discuss the stable concordance genus of a knot, which describes the behavior of the concordance genus under connected sum.

  13. Stable radiographic scanning agents

    International Nuclear Information System (INIS)

    1976-01-01

    Stable compositions which are useful in the preparation of Technetium-99m-based scintigraphic agents are discussed. They are comprised of ascorbic acid or a pharmaceutically acceptable salt or ester thereof in combination with a pertechnetate reducing agent or dissolved in oxidized pertechnetate-99m (sup(99m)TcO 4 - ) solution

  14. Some stable hydromagnetic equilibria

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, J L; Oberman, C R; Kulsrud, R M; Frieman, E A [Project Matterhorn, Princeton University, Princeton, NJ (United States)

    1958-07-01

    We have been able to find and investigate the properties of equilibria which are hydromagnetically stable. These equilibria can be obtained, for example, by wrapping conductors helically around the stellarator tube. Systems with I = 3 or 4 are indicated to be optimum for stability purposes. In some cases an admixture of I = 2 fields can be advantageous for achieving equilibrium. (author)

  15. [Breast cancer: histological prognosis from biopsy material].

    Science.gov (United States)

    Veith, F; Picco, C

    1977-01-01

    Two histological factors to be taken into consideration for prognosis in pretreatment schedules of breast cancer have been studied on a group of 352 cases treated by non-mutilating therapeutics at the Fondation Curie between 1960 and 1970. The tumour material the slides of which we have reexamined "blindly", i.e. ignoring the evolution of the case had been obtained mostly by drill-biopsy. Histological groups and types have been determined following an analytical classification for computer purpose. The degree of malignancy was calculated with the method of Scarff-Bloom-Richardson. The analyzed data have been memorized on computer and then confronted with the elements of the T.N.M. classification and the survival of the patients involved. It appeared that if drill-biopsie have been performed correctly the histological type may be defined in eighty percent of cases. And it is likewise possible to calculate the histological grade of malignancy for each mammary cancer. With such a material the value for prognosis by means of the Scarff-Bloom-Richardson method still remains if applied only to adenocarcinoma of the "common infiltrating type".

  16. Post biopsy pneumothorax: Risk factors and course

    International Nuclear Information System (INIS)

    Sanchez, J.A.; Retamar, J.A.; Blazquez, J.; Castano, J.C.

    1996-01-01

    The was to study the natural course of pneumothorax produced after aspiration biopsy in the attempt to differentiate those cases that will resolve spontaneously from those that will require drainage, and to assess the possible risk factors associated with the development of this entity. Eighty-nine CT-guided aspiration biopsies were performed in 80 patients. Control CT was done immediately after the procedure and 24 hours later. When pneumothorax persisted, CT was repeated at 48 h, 72 h, day 5 and day 7 or until a drainage tube was introduced. The cases of pneumothorax were classified as minimal, anterior or anterolateral. Seven variables were assessed as possible risk factors for its occurrence. Pneumothorax developed on 29 occasions (32.5%), requiring drainage in 12 cases (13.5%). In 20 patients (22%), pneumothorax occurred immediately, while in the remaining 9 (10%) it was detected in the 24 h CT scan. When studied according to type, drainage was required in 3 of the 19 cases of minimal or anterior pneumothorax (15%) and in 9 or the 10 cases of anterolateral location (90%) (p<0.0005). The mean thickness of the parenchyma punctured was 3.4 cm +- 2.2. cm when pneumothorax developed and 1.3 cm+- 2 cm when it did not (p<0.0001). There is a statistically significant association between the development of anterolateral pneumothorax and the need for chest drainage. The thickness of the punctured parenchyma is associated with the production of pneumothorax. 16 refs

  17. Dengue: muscle biopsy findings in 15 patients

    Directory of Open Access Journals (Sweden)

    S.M.F. Malheiros

    1993-06-01

    Full Text Available Dengue is known to produce a syndrome involving muscles, tendons and joints. The hallmark of this syndrome is severe myalgia but includes fever, cutaneous rash, and headache. The neuromuscular aspects of this infection are outlined only in isolated reports, and the muscle histopathological features during myalgia have not been described. In order to ascertain the actual neuromuscular involvement in dengue and better comprehend the histological nature of myalgia, we performed a clinical and neurological evaluation, a serum CPK level and a muscle biopsy (with histochemistry in 15 patients (4 males, median age 23 years (range 14-47 with classic dengue fever, serologically confirmed, during the bra-zilian dengue epidemics from September 1986 to March 1987. All patients had a history of fever, headache and severe myalgia. Upon examination 4 had a cutaneous rash, 3 had fever, and 3 a small hepatomegaly. The neurological examination was unremarkable in all and included a manual muscle test. CPK was mildly elevated in only 3 patients. Muscle biopsy revealed a light to moderate perivascular mononuclear infiltrate in 12 patients and lipid accumulation in 11. Mild mitochondrial proliferation was seen in 3, few central nuclei in 3, rare foci of myonecrosis in 3, and 2 patients had type grouping. Dengue in our patients, produced myalgia but no detectable muscle weakness or other neuromuscular involvement. The main histopathological correlation with myalgia seems to be a perivascular mononuclear infiltrate and lipid accumulation.

  18. Endometrial biopsy findings in postmenopausal bleeding

    International Nuclear Information System (INIS)

    Sarfraz, T.; Tariq, H.

    2007-01-01

    To study endometrial histopathology in women presenting with postmenopausal bleeding. A two-year study from January 2003 to December 2004 of 100 cases of postmenopausal bleeding was conducted at Combined Military Hospital, Sialkot. The histopathology of endometrial biopsy specimens was done to find out the causes of postmenopausal bleeding in these ladies. All these 100 patients had confirmed menopause and the average age was 55 years and above. The most common histopathological diagnosis was senile endometrial atrophy (27%), followed by simple cystic hyperplasia in (17%). Three cases of simple cystic hyperplasia had coexistent ovarian tumors. Glandular hyperplasia without atypia was seen in 6% and with atypia in 4%. Other causes were endometritis (13%), endometrial polyps (8%), proliferative phase endometrium (6%) and secretary phase endometrium (5%). Endometrial carcinoma was seen in (6%) cases, (8%) biopsy specimens were non-representative. Although senile endometrial atrophy was most commonly found in these ladies but a significant percentage of endometrial hyperplasia and endometrial cancer implies the need for investigating all cases of postmenopausal bleeding. Bimanual examination and pelvic ultrasonography should be combined with endometrial sampling so that rare pelvic pathologies may not be missed. (author)

  19. Celiac disease or positive tissue transglutaminase antibodies in patients undergoing renal biopsies.

    Science.gov (United States)

    Nurmi, Rakel; Metso, Martti; Pörsti, Ilkka; Niemelä, Onni; Huhtala, Heini; Mustonen, Jukka; Kaukinen, Katri; Mäkelä, Satu

    2018-01-01

    An association between celiac disease and renal diseases has been suggested, but the results are controversial. To investigate the prevalence of celiac disease autoimmunity among individuals undergoing renal biopsies and to evaluate whether co-existent celiac autoimmunity influences the clinical outcome of the renal disease. The prevalence of celiac autoimmunity (previous diagnosis of celiac disease or positive tissue transglutaminase antibodies) was determined in 827 consecutive patients undergoing kidney biopsies due to clinical indications. Up to 15 years' follow-up data on kidney function and co-morbidities were obtained. Celiac autoimmunity was found in 45 (5.4%) patients. Among the IgA nephropathy patients, 8.2% of had celiac autoimmunity. At the time of kidney biopsy and after a median follow-up of 5 to 6 years, renal function measured by estimated glomerular filtration rate (eGFR) was inferior in IgA nephropathy patients with celiac autoimmunity compared to those without it (P=0.048 and P=0.022, respectively). The prevalence of celiac autoimmunity seems to be high in patients undergoing renal biopsies, especially in patients with IgA nephropathy. Such autoimmunity may be associated with worse renal function in IgA nephropathy. Hence the co-existence of celiac disease should be taken into consideration when treating patients with renal diseases. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  20. Effects of Atorvastatin Dose and Concomitant Use of Angiotensin-Converting Enzyme Inhibitors on Renal Function Changes over Time in Patients with Stable Coronary Artery Disease: A Prospective Observational Study

    Science.gov (United States)

    Wieczorek-Surdacka, Ewa; Świerszcz, Jolanta; Surdacki, Andrzej

    2016-01-01

    Angiotensin-converting enzyme inhibitors (ACEI) and statins are widely used in patients with coronary artery disease (CAD). Our aim was to compare changes in glomerular filtration rate (GFR) over time in subjects with stable CAD according to atorvastatin dose and concomitant use of ACEI. We studied 78 men with stable CAD referred for an elective coronary angiography who attained the then-current guideline-recommended target level of low-density lipoproteins (LDL) cholesterol below 2.5 mmol/L in a routine fasting lipid panel on admission and were receiving atorvastatin at a daily dose of 10–40 mg for ≥3 months preceding the index hospitalization. Due to an observational study design, atorvastatin dosage was not intentionally modified for other reasons. GFR was estimated during index hospitalization and at about one year after discharge from our center. Irrespective of ACEI use, a prevention of kidney function loss was observed only in those treated with the highest atorvastatin dose. In 38 subjects on ACEI, both of the higher atorvastatin doses were associated with increasing beneficial effects on GFR changes (mean ± SEM: −4.2 ± 2.4, 1.1 ± 1.6, 5.2 ± 2.4 mL/min per 1.73 m2 for the 10-mg, 20-mg and 40-mg atorvastatin group, respectively, p = 0.02 by ANOVA; Spearman’s rho = 0.50, p = 0.001 for trend). In sharp contrast, in 40 patients without ACEI, no significant trend effect was observed across increasing atorvastatin dosage (respective GFR changes: −1.3 ± 1.0, −4.7 ± 2.1, 4.8 ± 3.6 mL/min per 1.73 m2, p = 0.02 by ANOVA; rho = 0.08, p = 0.6 for trend). The results were substantially unchanged after adjustment for baseline GFR or time-dependent variations of LDL cholesterol. Thus, concomitant ACEI use appears to facilitate the ability of increasing atorvastatin doses to beneficially modulate time-dependent changes in GFR in men with stable CAD. PMID:26848655

  1. Effects of percutaneous needle liver biopsy on dairy cow behaviour

    DEFF Research Database (Denmark)

    Mølgaard, Lene; Damgaard, Birthe Marie; Bjerre-Harpøth, Vibeke

    2012-01-01

    In cattle, percutaneous needle liver biopsy is used for scientific examination of liver metabolism. The impact of the biopsy procedure is, however, poorly investigated. Our aim was to examine the behaviour of dairy cows during and after liver biopsy. Data were collected from 18 dry cows....... Percutaneous needle liver biopsies (after administration of local anaesthesia (2% Procaine)) and blood samples were taken during restraining. During the control treatment, animals were restrained and blood sampled. During the biopsy procedure, cows showed increased restlessness (P = 0.008), frequency of head...... behavioural changes for up to 19 h – and particularly for behaviour previously associated with pain. Even though the exact welfare impact of percutaneous needle liver biopsies in cows is not known, and the magnitude of the behavioural changes was limited, pain always has negative effects on animal welfare...

  2. Chance and stability stable distributions and their applications

    CERN Document Server

    Uchaikin, Vladimir V

    1999-01-01

    An introduction to the theory of stable distributions and their applications. It contains a modern outlook on the mathematical aspects of the theory. The authors explain numerous peculiarities of stable distributions and describe the principle concept of probability theory and function analysis. A significant part of the book is devoted to applications of stable distributions. Another notable feature is the material on the interconnection of stable laws with fractals, chaos and anomalous transport processes.

  3. Image-guided pleural biopsy: diagnostic yield and complications

    International Nuclear Information System (INIS)

    Benamore, R.E.; Scott, K.; Richards, C.J.; Entwisle, J.J.

    2006-01-01

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease

  4. Image-guided pleural biopsy: diagnostic yield and complications

    Energy Technology Data Exchange (ETDEWEB)

    Benamore, R.E. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)]. E-mail: rachelbenamore@doctors.org.uk; Scott, K. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Richards, C.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom); Entwisle, J.J. [Department of Radiology and Department of Histopathology, Glenfield Hospital, University Hospitals of Leicester NHS Trust, Leicester (United Kingdom)

    2006-08-15

    Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory multidisciplinary team database and patient notes. A record was made of complications following biopsy, presence of pleura in the biopsy, and adequacy of tissue for histological diagnosis. Results: A total of 82 patients underwent 85 image-guided pleural biopsies over a 4-year period. 80 cases were performed under CT and five under US guidance. The rate of new pneumothorax detected by chest radiography was 4.7%. No patient required a chest drain or blood transfusion to treat complications. In 10 (12%) cases, there was inadequate tissue to reach a confident histological diagnosis and in eight (9%) of these, no pleura was present. Assuming all suspicious and inadequate biopsies are treated as benign, which is the worst case scenario, image-guided pleural biopsy has a sensitivity and specificity of 76% and 100%, respectively, for the diagnosis of malignant disease. Conclusions: Image-guided pleural biopsy is a safe procedure with few associated complications and has a higher sensitivity than previously published series for reverse cutting needle biopsy in the diagnosis of malignant pleural disease.

  5. Seven cases of upper gastrointestinal bleeding after cold biopsy

    OpenAIRE

    Alneaimi, Khaled; Abdelmoula, Ali; Vincent, Magalie; Savale, Camille; Baye, Birane; Lesur, Gilles

    2016-01-01

    Background and study aims: Routine biopsy of the upper gastrointestinal tract is performed with increasing frequency. It is generally considered to be safe without significant complication. However, gastrointestinal bleeding as a result of cold biopsy is a known complication. We report seven cases of upper gastrointestinal bleeding after cold biopsy and discuss clinical data, risks factors, severity and management of this event. We suggest that physicians must be more cautious with this rare ...

  6. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    OpenAIRE

    Adel S. Ahmed; Mostafa I. Ragab; Alaa eldin M. Elgazaar; Nagwan A. Ismail

    2016-01-01

    Introduction: Pleural biopsy for pathological confirmation is the standard diagnostic procedure for pleural diseases, transthoracic ultrasonography (TUS) has evolved as an important imaging tool for diagnosing pleural and pulmonary conditions. Aim of the study: To assess the diagnostic yield of TUS guided pleural biopsy versus both CT guided and thoracoscopic pleural biopsy in the diagnosis of undiagnosed exudative pleural effusion. Patients and methods: The study was conducted at chest...

  7. Stable isotope analysis

    International Nuclear Information System (INIS)

    Tibari, Elghali; Taous, Fouad; Marah, Hamid

    2014-01-01

    This report presents results related to stable isotopes analysis carried out at the CNESTEN DASTE in Rabat (Morocco), on behalf of Senegal. These analyzes cover 127 samples. These results demonstrate that Oxygen-18 and Deuterium in water analysis were performed by infrared Laser spectroscopy using a LGR / DLT-100 with Autosampler. Also, the results are expressed in δ values (‰) relative to V-SMOW to ± 0.3 ‰ for oxygen-18 and ± 1 ‰ for deuterium.

  8. Forensic Stable Isotope Biogeochemistry

    Science.gov (United States)

    Cerling, Thure E.; Barnette, Janet E.; Bowen, Gabriel J.; Chesson, Lesley A.; Ehleringer, James R.; Remien, Christopher H.; Shea, Patrick; Tipple, Brett J.; West, Jason B.

    2016-06-01

    Stable isotopes are being used for forensic science studies, with applications to both natural and manufactured products. In this review we discuss how scientific evidence can be used in the legal context and where the scientific progress of hypothesis revisions can be in tension with the legal expectations of widely used methods for measurements. Although this review is written in the context of US law, many of the considerations of scientific reproducibility and acceptance of relevant scientific data span other legal systems that might apply different legal principles and therefore reach different conclusions. Stable isotopes are used in legal situations for comparing samples for authenticity or evidentiary considerations, in understanding trade patterns of illegal materials, and in understanding the origins of unknown decedents. Isotope evidence is particularly useful when considered in the broad framework of physiochemical processes and in recognizing regional to global patterns found in many materials, including foods and food products, drugs, and humans. Stable isotopes considered in the larger spatial context add an important dimension to forensic science.

  9. Brain biopsy for diagnosis of chlamydia encephalitis

    Directory of Open Access Journals (Sweden)

    I. A. Voznyuk

    2017-01-01

    Full Text Available This is the case of encephalitis associated with chlamydia infection of central nervous system. The diagnostic protocol of the patient included: a careful observation of somatic and neurological status, laboratory tests of blood and cerebrospinal fluid, neurovisualization. The results of the diagnostic protocol suggest that laboratory tests blood and cerebrospinal fluid possess low sensitivity and specificity. The MRI study has revealed the localization and inflammatory character of the changes in brain tissue; it has also helped to choose the most favorable area for the stereotaxic biopsy. The obtained tissue was evaluated by means of light (immunohistochemistry and electronic microscopy. The active chlamydia infection was estimated. The subsequent antibacterial etiotropic therapy resulted in the regression of the neurologic symptoms and remission.The intravitalpathomorphology study of the brain could be recommended for the management of the severe encephalitis of the unknown origin. 

  10. CT guided biopsies as a part of the investigations in findings in the lung and thorax wall

    DEFF Research Database (Denmark)

    Vagn-Hansen, Chris Aksel; Pedersen, Malene Roland Vils; Rafaelsen, Søren Rafael

    was performed. Results: In 86 % of the biopsies, the tissue material was found sufficient. In 32 % of the biopsies there was a complication, mostly pneumothorax (30%), but in only 15 % of the 520 cases chest drainage was needed. There was one death in a known cancer patient with severe reduced lung and cardiac...... function. Patients with more than 10 cigarette pack years had a complication risk twice as high compared to patients with less pack years. We found that the risk of pneumothorax rises the further the lesion is from the skin surface, the smaller the lesions are and when the patient is biopsied in a lateral...... position. We found a higher risk of complications in females. Conclusion: CT guided biopsy is an excellent tool in the analysis of lesions in the lungs. This study clearly shows that the risk of developing a pneumothorax is significantly higher among smokers and former smokers with more than 10 pack years....

  11. Renal biopsies in children: current practice and audit of outcomes.

    Science.gov (United States)

    Hussain, Farida; Mallik, Meeta; Marks, Stephen D; Watson, Alan R

    2010-02-01

    There is considerable variation in the way that children are prepared for and the techniques employed in a renal biopsy. There was national agreement between UK paediatric renal centres to review current practice and audit outcomes An initial questionnaire survey was undertaken and a 12-month prospective audit performed of renal biopsies against agreed standards for the number of needle passes, adequacy of biopsy material and complication rates. Eleven of 13 centres participated. Information leaflets are sent pre-biopsy in five centres with only one using play preparation. Six of 11 routinely perform biopsies as day-case (DC) procedures and 6 use general anaesthesia (GA). Real-time ultrasound is the favoured method in eight centres. Biopsies are performed by nephrologists only in four centres, nephrologists with radiologists in five and radiology alone in two. Of 531 biopsies (352 native), 31% were performed as a DC with 49% being done under GA. The standard for the number of passes of native kidneys (95%). The major complication rate was higher than the standard of biopsy was performed as a DC or inpatient procedure (P = 0.73) or when GA or sedation was used (P = 0.8). The audit highlights significant variation in clinical practice with limited use of preparation materials and DC procedures. The results have stimulated constructive debate about preparation and indications for biopsy and training issues. The audit enables centres and individuals to monitor performance.

  12. CT Guided biopsies of musculoskeletal lesions, radiological and pathologic correlation

    International Nuclear Information System (INIS)

    Hadzihasanovic, B.; Milisic, L.; Zuban, J.; Mujic, E.; Jahic, E.; Gjikolli, B.; Hasanovic, B.; Lincender-Cvijetic, L.; Jaganjac, S.

    2006-01-01

    Full text: The aim of the study is to overview our experiences in taking the CT guided biopsies of musculoskeletal lesions during the period of sixteen months, analysis of validity of samples taken and correlation with pathological findings. CT guided biopsies of musculoskeletal lesions were performed in 32 patients during the period of sixteen months (from December 2004 until March 2006). Age range was from 13 to 78 years. Majorities of the biopsies were performed with coaxial cutting needle system (14 G and 16 G) with introducers size 13 and 15 G. Bone biopsies were performed with Yamsidi needles in purpose of taking the bone cylinder. Majorities of the biopsies were performed under local anaesthesia except a thirteen years old child to whom CT guided biopsy of corpus Th 6 was performed under general anaesthesia. Two samples of tissues were sent in formalin solutions to Pathology Institute for pathological verification. In one case of musculoskeletal lesions CT guided biopsies didn't yield a representative tissue sample. We had high level of congruence between radiological and pathological findings; precise presented in the article. CT guided biopsies of musculoskeletal lesions are method of choice for pathologic verification of musculoskeletal lesions proving incomparable less risk compared to 'open' biopsy which requires operating theatre and general anaesthesia. Coaxial needle systems has shown as suitable for yielding representative tissue samples (two samples for each patient), and samples are also appropriate for immunohistochemical analysis

  13. [Determination of the 120-day post prostatic biopsy mortality rate].

    Science.gov (United States)

    Canat, G A; Duclos, A; Couray-Targe, S; Schott, A-M; Polazzi, S; Scoazec, J-Y; Berger, F; Perrin, P

    2014-06-01

    Concerning death-rates were reported following prostate biopsy but the lack of contexts in which event occurred makes it difficult to take any position. Therefore, we aimed to determine the 120-day post-biopsy mortality rate. Between 2000 and 2011, 8804 men underwent prostate biopsy in the hospice civils de Lyon. We studied retrospectively, the mortality rate after each of the 11,816 procedures. Biopsies imputability was assessed by examining all medical records. Dates of death were extracted from our local patient management database, which is updated trimestrially with death notifications from the French National Institute for Statistics and Economic Studies. In our study 42 deaths occurred within 120days after 11,816 prostate biopsies (0.36%). Of the 42 records: 9 were lost to follow-up, 3 had no identifiable cause of death, 28 had an intercurrent event ruling out prostate biopsy as a cause of death. Only 2 deaths could be linked to biopsy. We reported at most 2 deaths possibly related to prostate biopsy over 11,816 procedures (0.02%). We confirmed the fact that prostate biopsies can be lethal but this rare outcome should not be considered as an argument against prostate screening given the circumstances in which it occurs. 5. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  14. Evaluation of an endoscopic liver biopsy technique in green iguanas.

    Science.gov (United States)

    Hernandez-Divers, Stephen J; Stahl, Scott J; McBride, Michael; Stedman, Nancy L

    2007-06-15

    To establish a safe and effective endoscopic technique for collection of liver biopsy specimens from lizards by use of a 2.7-mm rigid endoscope system that is commonly available in zoologic veterinary practice. Prospective study. 11 subadult male green iguanas (Iguana iguana). Each lizard was anesthetized, and right-sided coelioscopic examination of the right liver lobe and gallbladder was performed. Three liver biopsy specimens were collected from each lizard by use of a 2.7-mm rigid endoscope and 1.7-mm (5-F) biopsy forceps. Biopsy samples were evaluated histologically for quality and crush artifact. Ten days following surgery, all iguanas were euthanatized and underwent full necropsy examination. For all 11 iguanas, the right liver lobe and gallbladder were successfully examined endoscopically, and 3 biopsy specimens of the liver were collected without complications. Mean +/- SD durations of anesthesia and surgery were 24 +/- 7 minutes and 6.8 +/- 1.0 minutes, respectively. At necropsy, there was no evidence of trauma or disease associated with the skin or muscle entry sites, liver, or any visceral structures in any iguana. All 33 biopsy specimens were considered acceptable for histologic interpretation; in most samples, the extent of crush artifact was considered minimal. By use of a 2.7-mm rigid endoscope, liver biopsy procedures can be performed safely, swiftly, and easily in green iguanas. Biopsy specimens obtained by this technique are suitable for histologic examination. For evaluation of the liver and biopsy specimen collection in lizards, endoscopy is recommended.

  15. Greater Biopsy Core Number Is Associated With Improved Biochemical Control in Patients Treated With Permanent Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Bittner, Nathan; Merrick, Gregory S.; Galbreath, Robert W.; Butler, Wayne M.; Adamovich, Edward; Wallner, Kent E.

    2010-01-01

    Purpose: Standard prostate biopsy schemes underestimate Gleason score in a significant percentage of cases. Extended biopsy improves diagnostic accuracy and provides more reliable prognostic information. In this study, we tested the hypothesis that greater biopsy core number should result in improved treatment outcome through better tailoring of therapy. Methods and Materials: From April 1995 to May 2006, 1,613 prostate cancer patients were treated with permanent brachytherapy. Patients were divided into five groups stratified by the number of prostate biopsy cores (≤6, 7-9, 10-12, 13-20, and >20 cores). Biochemical progression-free survival (bPFS), cause-specific survival (CSS), and overall survival (OS) were evaluated as a function of core number. Results: The median patient age was 66 years, and the median preimplant prostate-specific antigen was 6.5 ng/mL. The overall 10-year bPFS, CSS, and OS were 95.6%, 98.3%, and 78.6%, respectively. When bPFS was analyzed as a function of core number, the 10-year bPFS for patients with >20, 13-20, 10-12, 7-9 and ≤6 cores was 100%, 100%, 98.3%, 95.8%, and 93.0% (p < 0.001), respectively. When evaluated by treatment era (1995-2000 vs. 2001-2006), the number of biopsy cores remained a statistically significant predictor of bPFS. On multivariate analysis, the number of biopsy cores was predictive of bPFS but did not predict for CSS or OS. Conclusion: Greater biopsy core number was associated with a statistically significant improvement in bPFS. Comprehensive regional sampling of the prostate may enhance diagnostic accuracy compared to a standard biopsy scheme, resulting in better tailoring of therapy.

  16. Prostate atypia: does repeat biopsy detect clinically significant prostate cancer?

    Science.gov (United States)

    Dorin, Ryan P; Wiener, Scott; Harris, Cory D; Wagner, Joseph R

    2015-05-01

    While the treatment pathway in response to benign or malignant prostate biopsies is well established, there is uncertainty regarding the risk of subsequently diagnosing prostate cancer when an initial diagnosis of prostate atypia is made. As such, we investigated the likelihood of a repeat biopsy diagnosing prostate cancer (PCa) in patients in which an initial biopsy diagnosed prostate atypia. We reviewed our prospectively maintained prostate biopsy database to identify patients who underwent a repeat prostate biopsy within one year of atypia (atypical small acinar proliferation; ASAP) diagnosis between November 1987 and March 2011. Patients with a history of PCa were excluded. Chart review identified patients who underwent radical prostatectomy (RP), radiotherapy (RT), or active surveillance (AS). For some analyses, patients were divided into two subgroups based on their date of service. Ten thousand seven hundred and twenty patients underwent 13,595 biopsies during November 1987-March 2011. Five hundred and sixty seven patients (5.3%) had ASAP on initial biopsy, and 287 (50.1%) of these patients underwent a repeat biopsy within one year. Of these, 122 (42.5%) were negative, 44 (15.3%) had atypia, 19 (6.6%) had prostatic intraepithelial neoplasia, and 102 (35.6%) contained PCa. Using modified Epstein's criteria, 27/53 (51%) patients with PCa on repeat biopsy were determined to have clinically significant tumors. 37 (36.3%) proceeded to RP, 25 (24.5%) underwent RT, and 40 (39.2%) received no immediate treatment. In patients who underwent surgery, Gleason grade on final pathology was upgraded in 11 (35.5%), and downgraded 1 (3.2%) patient. ASAP on initial biopsy was associated with a significant risk of PCa on repeat biopsy in patients who subsequently underwent definitive local therapy. Patients with ASAP should be counseled on the probability of harboring both clinically significant and insignificant prostate cancer. © 2015 Wiley Periodicals, Inc.

  17. [Prostate cancer diagnostic by saturation randomized biopsy versus rigid targeted biopsy].

    Science.gov (United States)

    Defontaines, J; Salomon, L; Champy, C; Cholley, I; Chiaradia, M; de la Taille, A

    2017-12-01

    Optimal diagram teaming up randomized biopsy (BR) to targeted biopsy (BC) is still missing for the diagnostic of prostate cancer (CP). This study compares diagram of 6, 12 or 18 BR with or without BC rigid. Between January 2014 and May 2016, 120 patients had prostate biopsy BR and BC. Each patient had 18 BR and BC. Results compared sextant (6 BR), standard (12 BR) and saturation (18 BR) protocol with or without the adding of BC for the detection of CP. Rectal examination was normal, mean PSA at 8.99ng/mL and mean volume at 54cm 3 . It was first round for 48% of patients. Forty-four cancers were found by the group 18 BR+BC (control). The detection rate was respectively, for 6, 12 and 18 BR of 61%, 82% and 91%. The add of BC increased this detection of +27% for 6 BR+BC, +13% for 12 BR+BC and +9% for 18 BR+BC. BC found 70% of all CP. Nine percent of CP were missed by BR only. Significant CP (Gleason≥7) diagnostic was the same for 12 BR+BC and 18 BR+BC. The add of BC to BR increase the detection of CP by 10%. Twelve BR+BC is the optimal diagram for the diagnostic of CP finding 95% of CP and 97% of significant CP. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  18. Qualidade de sono e função pulmonar em adolescentes portadores de anemia falciforme clinicamente estáveis Quality of sleep and pulmonary function in clinically stable adolescents with sickle cell anemia

    Directory of Open Access Journals (Sweden)

    Lisliê Capoulade Nogueira Arrais de Souza

    2007-06-01

    Full Text Available OBJETIVO: Avaliar a qualidade de sono e função pulmonar em adolescentes portadores de anemia falciforme (AF, clinicamente estáveis. MÉTODOS: Estudo trasversal descritivo de 50 pacientes portadores de AF submetidos a polissonografia noturna e espirometria no Hospital Universitário de Brasília. Analisamos dados antropométricos, polissonográficos e de função pulmonar. Dividimos os pacientes em dois grupos segundo a saturação periférica de oxigênio (SpO2 em sono com movimentos oculares rápidos (MOR: SpO2 93%. Realizamos estatística descritiva, teste t de Student, qui-quadrado e correlação de Pearson. RESULTADOS: A média de idade foi de 13,9 ± 2,5 anos. O tempo total de sono e percentagem do sono em MOR estavam diminuídos; dois pacientes (4% não apresentaram sono MOR. Latência de sono MOR, número de despertares, movimentação em sono, mudança de estágio, índice de distúrbios respiratórios e índice de apnéia obstrutiva estavam aumentados. Entre os dois grupos, houve diferenças estatisticamente significativas na maioria das variáveis polissonográficas. A SpO2 em sono MOR correlacionou-se de forma forte e positiva com a SpO2 em vigília, bem como com a SpO2 em sono não-MOR; e correlacionou-se de forma forte e negativa com a percentagem do tempo total de sono em que a SPO2 foi OBJECTIVE: To evaluate quality of sleep and pulmonary function in clinically stable adolescents with sickle cell anemia (SCA. METHODS: A cross-sectional descriptive study involving 50 patients with SCA submitted to nocturnal polysomnography and spirometry at the Brasília University Hospital. Anthropometric, polysomnographic and pulmonary function data were analyzed. Patients were divided into two groups according to oxygen saturation by pulse oximetry (SpO2 during rapid eye movement (REM sleep: SpO2 93%. Descriptive statistics, Student's t-test, chi-square test and Pearson's correlation coefficient were used. RESULTS: Mean age was 13.9 ± 2

  19. Exact simulation of max-stable processes.

    Science.gov (United States)

    Dombry, Clément; Engelke, Sebastian; Oesting, Marco

    2016-06-01

    Max-stable processes play an important role as models for spatial extreme events. Their complex structure as the pointwise maximum over an infinite number of random functions makes their simulation difficult. Algorithms based on finite approximations are often inexact and computationally inefficient. We present a new algorithm for exact simulation of a max-stable process at a finite number of locations. It relies on the idea of simulating only the extremal functions, that is, those functions in the construction of a max-stable process that effectively contribute to the pointwise maximum. We further generalize the algorithm by Dieker & Mikosch (2015) for Brown-Resnick processes and use it for exact simulation via the spectral measure. We study the complexity of both algorithms, prove that our new approach via extremal functions is always more efficient, and provide closed-form expressions for their implementation that cover most popular models for max-stable processes and multivariate extreme value distributions. For simulation on dense grids, an adaptive design of the extremal function algorithm is proposed.

  20. Role of Ultrasound Guided Biopsy of Thoracic Lesions | Elameen ...

    African Journals Online (AJOL)

    Objective: This prospective study is to evaluate and enhance the role of ultrasound in biopsy guidance of thoracic lesions. Methods: 55 patients were subjected for fine needle aspiration (FNA) and/or core needle biopsy (CNB) from peripheral chest lesions in Ribat University Hospital during the period from April 2011 and ...

  1. CT guided percutaneous needle biopsy of the chest: initial experience

    African Journals Online (AJOL)

    The objective of this article is to report our first experience of CT guided percutaneous thoracic biopsy and to demonstrate the accuracy and safety of this procedure. This was a retrospective study of 28 CT-Guided Percutaneous Needle Biopsies of the Chest performed on 24 patients between November 2014 and April 2015.

  2. CT‑guided percutaneous transthoracic lung biopsy: First experience ...

    African Journals Online (AJOL)

    Percutaneous lung biopsy had been described in the nineteenth century by Leyden, but image- guided needle chest biopsy only gained widespread acceptance in the 1970s. Currently, tissue sampling of a thoracic lesion is indicated when the diagnosis cannot be obtained by the non-invasive techniques and cytological ...

  3. A review of transrectal ultrasound guided prostate biopsies: Is there ...

    African Journals Online (AJOL)

    Objective: We compared our institution's initial experience with transrectal ultrasound-guided (TRUS) prostate biopsies in a single arm prospective study to a historical cohort of finger guided (FG) biopsies. The primary outcome measure was prostate cancer detection. We documented our findings on TRUS including the ...

  4. [Closed needle-biopsy in the diagnosis of neoplasms].

    Science.gov (United States)

    Sforza, M; Perelli Ercolini, M; Beani, G

    1979-04-01

    The AA. demonstrate with this communication the validity of the needle biopsie for the diagnosis of neoplasms. They had used it for the breast, thyroid, flg and some other superficial tumefactions. In the mass-screening for the feminine neoplasms the clinical examination and the needle biopsy are very good method for a careful diagnosis.

  5. Prostatic biopsy after irradiation therapy for prostatic cancer

    International Nuclear Information System (INIS)

    Scardino, P.T.; Wheeler, T.M.

    1985-01-01

    To determine the prognostic significance of a routine needle biopsy of the prostate performed six to thirty-six months after the completion of definitive radiotherapy, biopsy results were analyzed in 146 patients who had no evidence of disease at the time of biopsy and who received no other therapy before proved recurrence of the tumor. Patients were followed up a mean of 3.9 years after radioactive gold seed implantation and external beam irradiation. The total dose was 8,000 rad. Among 146 patients, 56 (38%) had one or more positive biopsy results within this time interval. The positive biopsy rate correlated with the clinical stage ranging from 17 per cent in Stage B1N to 59 per cent in Stage C1. The risk of developing local recurrence or distant metastases at any given time after irradiation therapy was markedly greater in those patients with a positive biopsy result (p less than 0.0005). Prostatic biopsy is an accurate means of measuring the success of radiotherapy. A positive postirradiation biopsy result carries grave prognostic implications for the patient and indicates that the treatment has failed

  6. Sentinel lymph node biopsy in breast cancer and melanoma

    NARCIS (Netherlands)

    Doting, Meintje Hylkje Edwina

    2007-01-01

    Summary and conclusions In the introduction, a short overview of the development of the sentinel lymph node biopsy concept is presented. In addition to melanoma and breast cancer, the usefulness of sentinel lymph node biopsy as a surgical assessment method for squamous cell carcinoma of penis and

  7. Short Communication Evaluation of an underwater biopsy probe for ...

    African Journals Online (AJOL)

    This study evaluated the use of a novel underwater biopsy probe designed to collect muscle and dermal tissue samples from large (170–220 cm total length), free-swimming bull sharks Carcharhinus leucas. The biopsy probe tissue retention rate was 87% after 23 trials, and the mean size of retained tissue was 310 mg (SD ...

  8. Diagnosis of prostate cancer with needle biopsy: Should all cases ...

    African Journals Online (AJOL)

    Background: The triad of digital rectal examination (DRE), serum prostate specific antigen, and transrectal ultrasound‑guided prostate biopsy is used in the detection of prostate cancer (PCa). It is recommended that all cases of PCa should be diagnosed with needle biopsy before treatment. The exclusion criteria for those ...

  9. Sensitivity of Computed Tomography‑guided Transthoracic Biopsies ...

    African Journals Online (AJOL)

    2018-03-05

    Mar 5, 2018 ... Introduction: The indications for open biopsies for intrathoracic lesions have become almost negligible. This development was made possible by less invasive maneuvers such as computed tomography‑guided (CT‑guided) biopsy, thoracoscopy or video‑assisted thoracoscopy, and bronchoscopy.

  10. Sensitivity of Computed Tomography‑guided Transthoracic Biopsies ...

    African Journals Online (AJOL)

    Introduction: The indications for open biopsies for intrathoracic lesions have become almost negligible. This development was made possible by less invasive maneuvers such as computed tomography‑guided (CT‑guided) biopsy, thoracoscopy or video‑assisted thoracoscopy, and bronchoscopy. CT‑guided percutaneous ...

  11. Magnetic resonance imaging guided biopsy of musculoskeletal lesions

    Directory of Open Access Journals (Sweden)

    Hung-Ta H. Wu

    2012-04-01

    Conclusion: Biopsy under MRI guidance is especially valuable for the localization of bone marrow lesions, viable tumors (after chemotherapy or radiation, and lesions that cannot be visualized using CT. It is both accurate and safe, is a good alternative biopsy method, and may be a good adjunctive technique for the localization of bone lesions for radiofrequency ablation or other interventional procedures.

  12. A novel technique for diaphragm biopsies in human patients.

    Science.gov (United States)

    Noullet, Séverine; Romero, Norma; Menegaux, Fabrice; Chapart, Maud; Demoule, Alexandre; Morelot-Panzini, Capucine; Similowski, Thomas; Gonzalez-Bermejo, Jésus

    2015-06-15

    The diaphragm is difficult to biopsy because of its anatomic location. We describe a new laparoscopic diaphragm biopsy technique. Fifty one patients with amyotrophic lateral sclerosis gave their consent to diaphragm biopsy in the context of an implanted phrenic nerve stimulation protocol (NCT01583088). The biopsy was taken from the costal diaphragm, after opening the parietal peritoneum with scissors, and by grasping the diaphragmatic muscle over the rib with toothed laparoscopy forceps. The first four electrocoagulation biopsies were unsuitable for morphologic examination. The following 47 biopsies were therefore performed without electrocoagulation. The mean size of the biopsy fragments obtained after preparation was 3 ± 1 × 2 ± 1 × 1 ± 1 mm (maximum: 4 × 3 × 2 mm). A diaphragmatic injury occurred during the section in three cases requiring immediate suture without causing pneumothorax. A small pleural effusion was observed on the postoperative chest x-ray in one patient with a spontaneously favorable outcome. Numerous stains were able to be performed on the fragments obtained. Diaphragm biopsy can be safely performed by laparoscopy and yields tissue suitable for our future histologic evaluation. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Biopsying southern right whales : Their reactions and effects on reproduction

    NARCIS (Netherlands)

    Best, PB; Reeb, D; Rew, MB; Palsboll, PJ; Schaeff, C; Brandao, A

    Collecting skin biopsies from large whales for genetic analysis is often subject to national permit, and in the case of cow-calf pairs, it may be prohibited. We present results of 906 biopsy attempts on southern fight whales (Eubalaena australis) in South African waters between 1995 and 1997,

  14. Duodenal versus jejunal biopsies in suspected celiac disease

    NARCIS (Netherlands)

    Thijs, WJ; van Baarlen, J; Kleibeuker, JH; Kolkman, JJ

    2004-01-01

    Background and Study Aims: In the past, small-bowel biopsies for diagnosis of celiac disease were taken from the jejunum with a suction capsule, but nowadays most physicians take endoscopic biopsies from the distal duodenum. To validate that practice we compared the diagnostic yield of endoscopic

  15. Testicular Biopsy In The Evaluation Of Male Infertility In Maiduguri ...

    African Journals Online (AJOL)

    Objective: To evaluate testicular biopsy in the management of male infertility in the university of Maiduguri Teaching Hospital. Method: This study reviewed retrospectively testicular biopsy in the infertile males managed at University of Maiduguri Teaching Hospital between january 1991 and December 2000.

  16. Diffuse reflectance imaging: a tool for guided biopsy

    Science.gov (United States)

    Jayanthi, Jayaraj L.; Subhash, Narayanan; Manju, Stephen; Nisha, Unni G.; Beena, Valappil T.

    2012-01-01

    Accurate diagnosis of premalignant or malignant oral lesions depends on the quality of the biopsy, adequate clinical information and correct interpretation of the biopsy results. The major clinical challenge is to precisely locate the biopsy site in a clinically suspicious lesion. Dips due to oxygenated hemoglobin absorption have been noticed at 545 and 575 nm in the diffusely reflected white light spectra of oral mucosa and the intensity ratio R545/R575 has been found suited for early detection of oral pre-cancers. A multi-spectral diffuse reflectance (DR) imaging system has been developed consisting of an electron multiplying charge coupled device (EMCCD) camera and a liquid crystal tunable filter for guiding the clinician to an optimal biopsy site. Towards this DR images were recorded from 27 patients with potentially malignant lesions on their tongue (dorsal, lateral and ventral sides) and from 44 healthy controls at 545 and 575 nm with the DR imaging system. False colored ratio image R545/R575 of the lesion provides a visual discerning capability that helps in locating the most malignant site for biopsy. Histopathological report of guided biopsy showed that out of the 27 patients 16 were cancers, 9 pre-cancers and 2 lichen planus. In this clinical trial DR imaging has correctly guided 25 biopsy sites, yielding a sensitivity of 93% and a specificity of 98%, thereby establishing the potential of DR imaging as a tool for guided biopsy.

  17. Comparison between Doppler Ultrasound and Biopsy Findings in ...

    African Journals Online (AJOL)

    Methods: We retrospectively studied a random sample of 188 kidney transplanted patients who had Doppler-ultrasound examination followed within two weeks by transplant biopsy. We evaluated the specificity and sensitivity of Doppler ultrasound in diagnosing rejection at different RI thresholds, using the reported biopsy ...

  18. Ultrastructural examination of skin biopsies may assist in diagnosing mitochondrial cytopathy when muscle biopsies yield negative results.

    Science.gov (United States)

    McAfee, John L; Warren, Christine B; Prayson, Richard A

    2017-08-01

    Ultrastructural evaluation of skin biopsies has been utilized for diagnosis of mitochondrial disease. This study investigates how frequently skin biopsies reveal mitochondrial abnormalities, correlates skin and muscle biopsy findings, and describes clinical diagnoses rendered following the evaluation. A retrospective review of surgical pathology reports from 1990 to 2015 identified skin biopsies examined by electron microscopy for suspected metabolic disease. A total of 630 biopsies were included from 615 patients. Of these patients, 178 also underwent a muscle biopsy. Of the 630 skin biopsies, 75 (12%) showed ultrastructural abnormalities and 34 (5%) specifically showed mitochondrial abnormalities including increased size (n=27), reduced or abnormal cristae (n=23), dense matrices (n=20), and increased number (n=8). Additional findings included lysosomal abnormalities (n=13), lipid accumulation (n=2) or glycogen accumulation (n=1). Of the 34 patients with mitochondrial abnormalities on skin biopsy, 20 also had muscle biopsies performed and nine showed abnormalities suggestive of a mitochondrial disorder including absent cytochrome oxidase staining (n=2), increased subsarcolemmal NADH, SDH, or cytochrome oxidase staining (n=1), or ultrastructural findings including large mitochondrial size (n=5), abnormal mitochondrial structure (n=5), and increased mitochondrial number (n=4). The most common presenting symptoms were intellectual disability (n=13), seizures (n=12), encephalopathy (n=9), and gastrointestinal disturbances (n=9). At last known follow-up, 12 patients had a definitive diagnosis of a mitochondrial disorder. One patient each had Complex I deficiency, Complex III deficiency, Charcot-Marie-Tooth disease, pyruvate dehydrogenase deficiency, and Phelan-McDermid syndrome. Our results suggest that skin biopsy sometimes yields diagnostic clues suggestive of a mitochondrial cytopathy in cases with a negative muscle biopsy. Copyright © 2017 Elsevier Inc. All rights

  19. Repeated biopsies in prostate cancer patients on active surveillance

    DEFF Research Database (Denmark)

    Thomsen, Frederik Birkebaek; Marcussen, Niels; Berg, Kasper Drimer

    2015-01-01

    OBJECTIVE: To investigate the clinical implications of interobserver variation in the assessment of re-biopsies obtained during active surveillance (AS). MATERIAL AND METHODS: A total of 107 low-risk prostate cancer patients with a total of 93 diagnostic biopsy sets and 109 re-biopsy sets were...... included. The ISUP 2005 Gleason scoring system was applied for the histopathological assessment of all biopsies. Three different definitions of histopathological progression were applied. Unweighted and linear weighted Kappa statistics were used to compare the interobserver agreement. RESULTS: The overall...... recommendations would have changed in up to 10.1% (95% CI: 5.4%-17.7%) of the 109 re-biopsy sets. CONCLUSION: Kappa statistics demonstrated a strong agreement between the histological evaluations. Still, up to 10% of AS patients would receive different treatment recommendation depending upon which...

  20. Painful percutaneous transthoracic needle biopsy of Schwannoma: a case report

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chun, Kyung Ah; Kim, Young Joo; Park, Seog Hee; Shin, Kyung Sub; Lee, Eun Jung

    1995-01-01

    Percutaneous aspiration needle biopsy of the intrathoracic disease is a safe, easy, and accurate diagnostic method. It usually causes mild pain or discomfort during the procedure. We had a patient who complained of severe sharp pain, well localized at the biopsy site of the target mass during CT-guided transthoracic aspiration biopsy. It was pathologically confirmed as an intrathoracic schwannoma after special staining. To our knowledge, there has been no published report of such a painful percutaneous needle biopsy in a patient with schwannoma in Korea. Two cases were reported in other radiologic journals. The severe sharp pain developed during the transthoracic aspiration needle biopsy is a reliable sign of neurogenic tumor, therefore the participating radiologist should recommend specific immumochemical stain for neurogenic tumor to pathologist

  1. Aspiration biopsy of testis: another method for histologic examination

    International Nuclear Information System (INIS)

    Nseyo, U.O.; Englander, L.S.; Huben, R.P.; Pontes, J.E.

    1984-01-01

    The most important method for evaluating the pathogenesis of male infertility is open testicular biopsy. Herein the authors describe a method of aspiration biopsy of testis for histologic examination. Sexually mature dogs and rats treated with chemotherapeutic agents and ionizing radiation were followed with periodic testicular aspiration biopsy during and after treatment. The histologic findings from the aspiration biopsy compare with the results of routine histologic examination in assessing spermatogenetic activity and delineating pathologic changes. The puncture in the experimental animals was performed under general anesthesia. In human patients testicular biopsy could be done under local anesthesia in an outpatient clinic. The procedure would be less painful, minimally invasive, and more cost-effective

  2. MRI screening-detected breast lesions in high-risk young women: the value of targeted second-look ultrasound and imaging-guided biopsy.

    Science.gov (United States)

    Peter, P; Dhillon, R; Bose, S; Bourke, A

    2016-10-01

    To analyse the value of targeted second-look ultrasound and imaging-guided biopsy in high-risk young women eligible for screening magnetic resonance imaging (MRI) in a tertiary referral centre in Perth, Western Australia. A retrospective analysis of eligible high-risk young women who underwent screening breast MRI and targeted second-look ultrasound between June 2012 and June 2014 was performed with review of data. Over a 2-year period, 139 women underwent high-risk screening MRI. Of these, 30 women (with a total of 45 lesions) were recalled for targeted second-look ultrasound. Thirty-four MRI-detected lesions were identified on targeted ultrasound with 19 of them proceeding to ultrasound-guided biopsy, while the remaining 15 lesions were considered benign on ultrasound, were not biopsied, and were stable on follow-up imaging 12 months later. One lesion proceeded to an MRI-guided biopsy to confirm a benign result. Of the 11 lesions not seen on ultrasound, nine underwent MRI biopsy, one proceeded directly to hook wire localisation and excision, and one did not return for biopsy and was lost to follow-up. The overall biopsy rate was 14.4%. The cancer detection rate was 1.4%. The results of this study indicate that targeted second-look ultrasound and ultrasound-guided biopsy is a cost-effective and time-efficient approach for MRI-detected lesions in young women at high risk of developing breast cancer. MRI-guided biopsy should be considered for ultrasonographically occult suspicious lesions as there is a low, but definite, risk of cancer. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  3. Impact of Simulation-Based Training on Radiology Trainee Education in Ultrasound-Guided Breast Biopsies.

    Science.gov (United States)

    Roark, Ashley A; Ebuoma, Lilian O; Ortiz-Perez, Tamara; Sepulveda, Karla A; Severs, Frederick J; Wang, Tao; Benveniste, Ana Paula; Sedgwick, Emily L

    2017-12-05

    The aim of this study is to determine the impact of a simulation-based ultrasound-guided (USG) breast biopsy training session on radiology trainee procedural knowledge, comfort levels, and overall procedural confidence and anxiety. Twenty-one diagnostic radiology residents from a single academic institution were recruited to participate in an USG breast biopsy training session. The residents filled out a questionnaire before and after the training session. Ten multiple-choice questions tested general knowledge in diagnostic breast ultrasound and USG breast biopsy concepts. Subjective comfort levels with ultrasound machine and biopsy device functionality, patient positioning, proper biopsy technique, image documentation, needle safety and overall procedural confidence and anxiety levels were reported on a 5-point Likert scale before and after training. Participants demonstrated significant improvement in number of correctly answered general knowledge questions after training (P simulation-based USG breast biopsy training session may improve radiology trainee procedural knowledge, comfort levels, and overall procedural confidence. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  4. Periodicity of the stable isotopes

    CERN Document Server

    Boeyens, J C A

    2003-01-01

    It is demonstrated that all stable (non-radioactive) isotopes are formally interrelated as the products of systematically adding alpha particles to four elementary units. The region of stability against radioactive decay is shown to obey a general trend based on number theory and contains the periodic law of the elements as a special case. This general law restricts the number of what may be considered as natural elements to 100 and is based on a proton:neutron ratio that matches the golden ratio, characteristic of biological and crystal growth structures. Different forms of the periodic table inferred at other proton:neutron ratios indicate that the electronic configuration of atoms is variable and may be a function of environmental pressure. Cosmic consequences of this postulate are examined. (author)

  5. Morphologic Features Suggestive of Endometriosis in Nondiagnostic Peritoneal Biopsies.

    Science.gov (United States)

    Harrison, Beth T; Mittal, Khush

    2015-11-01

    Endometriosis is a common disorder that causes significant morbidity from dysmenorrhea, pelvic pain, and subfertility. Establishment of a definitive diagnosis has important therapeutic implications; however, only approximately 50% of biopsies of laparoscopically suspicious areas provide a diagnosis of endometriosis. Histologic criteria for diagnosis require the presence of endometrial glands or endometrial-type stroma. We hypothesize that other frequently present, but nondiagnostic, histologic features of endometriosis suggest its presence in patients with nondiagnostic peritoneal biopsies. We performed a retrospective clinicopathologic study of morphologic and immunohistochemical features that may improve the histologic diagnosis of endometriosis on laparoscopic peritoneal biopsies. We compared diagnostic (n=88) and nondiagnostic (n=54) peritoneal biopsies from pathologically confirmed endometriosis cases with negative peritoneal biopsies (n=84) from early-stage gynecologic cancer cases. Statistical analysis utilized the Fisher exact test. Multiple morphologic features were significantly increased in nondiagnostic biopsies from patients with endometriosis in comparison with those from negative controls, including foamy macrophages (P=0.0001) and submesothelial stromal clusters (SSCs) (P=0.0008). SSCs ranged from subtle aggregates of spindle cells to nodules of whorled spindle cells with small vessels and extravasated red blood cells resembling stromal endometriosis. Immunohistochemical studies confirmed that ER and CD10-positive SSCs were present in a greater proportion of both nondiagnostic and diagnostic peritoneal biopsies and at a greater number of lesions per biopsy. The overall histologic detection rate of peritoneal biopsies for endometriosis was 62.0%, and inclusion of SSCs with or without foamy macrophages in the diagnostic criteria appreciably increased this rate to between 72.5% and 76.8%. We describe SSCs, which appear to be an early or less developed

  6. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  7. Optical Systems of Biopsy: The Invisible Eye

    Directory of Open Access Journals (Sweden)

    Kriti Bagri-Manjrekar

    2012-01-01

    Full Text Available The exploration of new methods and techniques for the diagnosis of malignant tumours has always attracted the attention of scientists. The development of adjunct tools to facilitate the non invasive screening of high risk lesions in real time has the potential to significantly improve our ability to reduce the dismal morbidity and mortality of oral cancer. Despite easy accessibility of the oral cavity to examination, there is no satisfactory method to adequately screen and detect precancers non-invasively. The current method of oral cancer diagnosis clinically relies heavily on visual examination of the oral cavity. However, discerning potentially malignant and early malignant lesions from common benign inflammatory conditions can be difficult at times. There is a need for an objective method that could provide real- time results and be routinely applied to a large population. Though science is yet to present such a perfect technique, Optical Biopsy Systems developed using knowledge of light and tissue interaction, can provide a plausible option.

  8. Hybrid tracers for sentinel node biopsy

    International Nuclear Information System (INIS)

    Van Den Berg, N. S.; Kleinjan, G. I.; Valdés-Olmos, R. A.; Buckle, T.; Van Leeuwen, F. I.; Klop, W. M.; Horenblas, S.; Van Der Poel, H. G.

    2014-01-01

    Conventional sentinel node (SN) mapping is performed by injection of a radiocolloid followed by lymphoscintigraphy to identify the number and location of the primary tumor draining lymph node(s), the so-called SN(s). Over the last decade research has focused on the introduction of new imaging agents that can further aid (surgical) SN identification. Different tracers for SN mapping, with varying sizes and isotopes have been reported, most of which have proven their value in a clinical setting. A major challenge lies in transferring this diagnostic information obtained at the nuclear medicine department to the operating theatre thereby providing the surgeon with (image) guidance. Conventionally, an intraoperative injection of vital blue dye or a fluorescence dye is given to allow intraoperative optical SN identification. However, for some indications, the radiotracer-based approach remains crucial. More recently, hybrid tracers, that contain both a radioactive and fluorescent label, were introduced to allow for direct integration of pre- and intraoperative guidance technologies. Their potential is especially high when they are used in combination with new surgical imaging modalities and navigation tools. Next to a description of the known tracers for SN mapping, this review discusses the application of hybrid tracers during SN biopsy and how the introduction of these new techniques can further aid in translation of nuclear medicine information into the operating theatre.

  9. [Presence of Helicobacter pylori in gastric biopsies and feces of pediatric patients with celiac disease].

    Science.gov (United States)

    Medina, M G; Medina, M L; Martín, G T; Dikstein, B C; Picón, S O; Gorodner, J O; Merino, L A

    2009-01-01

    Helicobacter pylori (H. pylori) is the main etiologic agent of chronic gastritis and it is an important cause of gastric damage. The celiac disease can affect the morphology and the function of the gastrointestinal tract from the stomach to the colon and it is frequently associated with chronic gastritis. to assess the presence of H. pylori in gastric biopsies and in feces of pediatric patients with celiac disease and to relate it with the symptoms. Pediatric patients with celiac disease attending the Gastroenterology Service at the "Avelino Castelán" Hospital in Resistencia (Argentina) were included in the study. Gastric biopsies samples were obtained by endoscopy for histological studies, the symptoms and socio-epidemiological characteristics were recorded and the polimerase chain reaction(PCR) was applied in feces in order to detect the presence of H. pylori. Thirty one patients with celiac disease were studied (16 female and 15 male; age range:1-14 years; median 6.7 years); 14 (45.2%) were positive for H. pylori in gastric biopsy and among them, only 2 (14.2%) were positive for H. pylori in stool samples. There were not significant differences between symptoms between H. pylori positive and negative patients. 45.2% of the patients with celiac disease were infected by H. pylori. There was no correlation between the frequencies of bacterial detection in feces and in gastric biopsies. The clinical manifestations of celiac disease did not increase in children infected with H. pylori.

  10. Value of Renal Biopsy in Diagnosing Infantile Nephropathic Cystinosis Associated With Secondary Nephrogenic Diabetes Insipidus.

    Science.gov (United States)

    Joyce, Emily; Ho, Jacqueline; El-Gharbawy, Areeg; Salgado, Cláudia M; Ranganathan, Sarangarajan; Reyes-Múgica, Miguel

    2017-01-01

    Cystinosis is the most common cause of inherited renal Fanconi syndrome in young children, and typically presents with laboratory findings of a proximal tubulopathy and corneal crystals by one year of age. We describe here renal biopsy findings in a 20-month-old patient with an atypical presentation of distal renal tubular acidosis, diabetes insipidus, and the absence of corneal crystals. Although renal biopsy is usually not necessary to establish the diagnosis of cystinosis, when the patient presents with atypical signs and symptoms, a renal biopsy may be extremely valuable. A 20-month-old boy presented with failure to thrive, polyuria, polydipsia, and rickets. He initially showed evidence of a renal tubular acidosis, mild renal insufficiency, and nephrogenic diabetes insipidus. His initial ophthalmologic examination did not demonstrate corneal crystals. His subsequent workup revealed phosphaturia, suggesting a partial proximal tubulopathy. Concomitantly, a renal biopsy revealed prominent podocytes with an immature glomerular appearance, and electron microscopy analysis showed numerous intracellular crystals within tubular epithelial cells. Subsequent laboratory and genetic testing confirmed a diagnosis of infantile nephropathic cystinosis. This case highlights the variability in the clinical presentation of cystinosis, resulting in an uncommon clinical picture of a rare disease. Given that treatment is available to prolong renal function and minimize the extra-renal manifestations of this disorder, early diagnosis is essential. It is important to raise the index of suspicion of cystinosis by recognizing its subtle morphological changes in young patients, and that nephrogenic diabetes insipidus can be secondary to this disorder.

  11. Selection for biopsy of kidney transplant patients by diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Steiger, Philipp; Barbieri, Sebastiano; Ith, Michael; Thoeny, Harriet C. [Inselspital, Bern University Hospital, University of Bern, Inselspital, Department of Radiology, Neuroradiology, and Nuclear Medicine, Institute of Diagnostic, Pediatric, and Interventional Radiology, Bern (Switzerland); Kruse, Anja [Inselspital, Bern University Hospital, University of Bern, Inselspital, Department of Nephrology and Hypertension, Bern (Switzerland)

    2017-10-15

    To assess retrospectively whether diffusion-weighted magnetic resonance imaging (DW-MRI) allows physicians to determine the severity of histopathologic findings in biopsies of renal allograft patients with deteriorating renal function. Forty consecutive kidney transplant patients underwent DW-MRI and biopsy. Patients were assigned to one group with severe and to another group with normal or mild histopathologic findings. These two groups were compared based on a qualitative DW-MRI assessment (homo-/heterogeneity) and the combination of qualitative and quantitative DW-MRI parameters (ADC, and intravoxel incoherent motion, IVIM, parameters: D, f, D*). Sensitivity, specificity, and accuracy were determined for each parameter. Biopsy findings were severe in 25 patients and normal or mild in 15 patients. Qualitative DW-MRI led to a sensitivity of 44.0% and a specificity of 93.3%. Combined qualitative and quantitative DW-MRI led to an accuracy of 80% for both the minimal ADC (ADCmin) and the minimal perfusion fraction (fmin) with a sensitivity of 84.0% and 92.0% and a specificity of 73.3% and 60.0%, respectively. Combined qualitative and quantitative DW-MRI might allow physicians to determine the severity of histopathologic findings in biopsies of a high number of kidney transplant patients. (orig.)

  12. Percutaneous biopsy of malignant hepatic tumor in patients with bleeding tendency : usefulness of gelfoam plugging up the biopsy track

    International Nuclear Information System (INIS)

    Yoon, Hye Ran; Kwak, Byung Kook; Choi, Chi Hoon; Park, Yong Ok; Yang, Keun Myeong; Seo, Ja Young; Lee, Shin Hyung; Lee, Chang Joon; Shim, Hyung Jin

    1998-01-01

    To plug the biopsy site in eight patients with coagulopathy who had undergone percutaneous liver biopsy. To this end, gelfoam cartridge was used as a sealant. Materials and Methods: Using an 18G Tru-Cut-type disposable automated biopsy gun(Soo Ho Medi-tech, Seoul, Korea) and under US guidance, eight patients underwent percutaneous liver biopsy. After the gun had fired, the biopsy specimen in the inner stylet was retrieved while the outer cannula was held in place ; the cannula was then used to plug the biopsy tracks with gelfoam, using two or three cartridges. If bleeding occurred, this was controlled by the use of more gelfoam cartridges. Results:Diagnostic target tissue was obtained in seven of the eight patients(87.5%). Hepatocellular carcinoma was diagnosed in five cases and metastatic cancer in two. Profuse bleeding was observed in one patient(12.5%) and resolved by gelfoam plugging. Conclusion: We believe that in patients with coagulopathy who are required to undergo liver biopsy plugging the liver biopsy track with gelfoam cartridge is a simple, safe and useful method

  13. Stereotactic large-core needle breast biopsy: analysis of pain and discomfort related to the biopsy procedure

    International Nuclear Information System (INIS)

    Hemmer, Judith M.; Heesewijk, Hans P.M. van; Kelder, Johannes C.

    2008-01-01

    The purpose of this study was to determine the significance of variables such as duration of the procedure, type of breast tissue, number of passes, depth of the biopsies, underlying pathology, the operator performing the procedure, and their effect on women's perception of pain and discomfort during stereotactic large-core needle breast biopsy. One hundred and fifty consecutive patients with a non-palpable suspicious mammographic lesions were included. Between three and nine 14-gauge breast passes were taken using a prone stereotactic table. Following the biopsy procedure, patients were asked to complete a questionnaire. There was no discomfort in lying on the prone table. There is no relation between type of breast lesion and pain, underlying pathology and pain and performing operator and pain. The type of breast tissue is correlated with pain experienced from biopsy (P = 0.0001). We found out that patients with dense breast tissue complain of more pain from biopsy than patients with more involution of breast tissue. The depth of the biopsy correlates with pain from biopsy (P = 0.0028). Deep lesions are more painful than superficial ones. There is a correlation between the number of passes and pain in the neck (P = 0.0188) and shoulder (P = 0.0366). The duration of the procedure is correlated with pain experienced in the neck (P = 0.0116) but not with pain experienced from biopsy. (orig.)

  14. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    Science.gov (United States)

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  15. The Positive Outcome of MRI-Guided Vacuum Assisted Core Needle Breast Biopsies Is Not Influenced by a Prior Negative Targeted Second-Look Ultrasound.

    Science.gov (United States)

    Ferré, Romuald; AlSharif, Shaza; Aldis, Ann; Mesurolle, Benoît

    2017-11-01

    The study sought to investigate the outcome of breast magnetic resonance-guided biopsies as a function of the indication for magnetic resonance imaging (MRI), the MRI features of the lesions, and the performance or not of a targeted second-look ultrasound (SLUS) prior breast MRI-guided biopsy. We identified 158 women with MRI-detected breast lesions scheduled for MRI-guided biopsy (2007-2013). Patient demographics, performance of targeted SLUS, imaging characteristics, and subsequent pathology results were reviewed. Three biopsies were deferred, and 155 lesions were biopsied under MRI guidance (155 women; median age 55.14 years; range 27-80 years). Ninety-eight women underwent a SLUS prior to the MRI-guided biopsy (63%). Of the 155 biopsied lesions, 23 (15%) were malignant, 106 (68%) were benign, and 26 (17%) were high risk. Four of 15 surgically excised high-risk lesions were upgraded to malignancy (27%). Most of the biopsied lesions corresponded to non-mass-like enhancement (81%, 126 of 155) and most of the biopsies (52%, 81 of 155) were performed in a screening context. No demographic or MRI features were associated with malignancy. No differences were noted between the 2 subgroups (prior SLUS vs no prior SLUS) except for the presence of a synchronous carcinoma associated with a likelihood of targeted SLUS before MRI-guided biopsy (P = .001). A negative SLUS does not influence the pathology outcome of a suspicious lesion biopsied under MR guidance. Copyright © 2017 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  16. Theory of stable allocations

    Directory of Open Access Journals (Sweden)

    Pantelić Svetlana

    2014-01-01

    Full Text Available The Swedish Royal Academy awarded the 2012 Nobel Prize in Economics to Lloyd Shapley and Alvin Roth, for the theory of stable allocations and the practice of market design. These two American researchers worked independently from each other, combining basic theory and empirical investigations. Through their experiments and practical design they generated a flourishing field of research and improved the performance of many markets. Born in 1923 in Cambridge, Massachusetts, Shapley defended his doctoral thesis at Princeton University in 1953. For many years he worked at RAND, and for more than thirty years he was a professor at UCLA University. He published numerous scientific papers, either by himself or in cooperation with other economists.

  17. Bi-stable optical actuator

    Science.gov (United States)

    Holdener, Fred R.; Boyd, Robert D.

    2000-01-01

    The present invention is a bi-stable optical actuator device that is depowered in both stable positions. A bearing is used to transfer motion and smoothly transition from one state to another. The optical actuator device may be maintained in a stable position either by gravity or a restraining device.

  18. CT-guided biopsy with cutting-edge needle for the diagnosis of malignant lymphoma: Experience of 267 biopsies

    International Nuclear Information System (INIS)

    Agid, R.; Sklair-Levy, M.; Bloom, A.I.; Lieberman, S.; Polliack, A.; Ben-Yehuda, D.; Sherman, Y.; Libson, E.

    2003-01-01

    AIM: We performed a retrospective study of 267 core needle aspiration biopsies in order to estimate the accuracy of CT-guided aspiration core needle biopsies for the diagnosis and subsequent treatment of malignant lymphoma. MATERIALS AND METHODS: Between 1989 and 1999, 267 CT-guided core needle biopsies were performed in 241 patients with either primary or recurrent malignant lymphoma. Patients age ranged from 4--88 years. One hundred and sixty-six (62.2%) nodal and 101 (37.8%) extranodal aspiration biopsies were performed using either 18 G or 20 G Turner needles. Statistical method used was Chi-square analysis. RESULTS: An accurate histological diagnosis was made in 199 (82.5%) patients, the remaining 42 (17.4%) patients had non-diagnostic CT biopsies. Thirty-seven of them were diagnosed by a surgical biopsy, four by bone marrow biopsy and in one patient by paracentesis. One hundred and seventy-nine patients had non-Hodgkin's lymphoma (NHL) and 62 had Hodgkin's disease (HD); 23 (9.54%) patients underwent repeated CT biopsy which was diagnostic in 17 (73.9%) and non-diagnostic in six (26%). CONCLUSION: CT-guided aspiration core biopsies were sufficient to establish a diagnosis in lymphoproliferative disorders in 82.5% of cases. In the light of this experience we suggest that imaging-guided core needle biopsy be used as the first step in the work up of many patients with lymphoma Agid,R. et al. (2003). Clinical Radiology58, 143-147

  19. Comparison of Battery-Powered and Manual Bone Biopsy Systems for Core Needle Biopsy of Sclerotic Bone Lesions.

    Science.gov (United States)

    Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S

    2016-05-01

    The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.

  20. Are concurrent systematic cores needed at the time of targeted biopsy in patients with prior negative prostate biopsies?

    Science.gov (United States)

    Albisinni, S; Aoun, F; Noel, A; El Rassy, E; Lemort, M; Paesmans, M; van Velthoven, R; Roumeguère, T; Peltier, A

    2018-01-01

    MRI-guided targeted biopsies are advised in patients who have undergone an initial series of negative systematic biopsies, in whom prostate cancer (PCa) suspicion remains elevated. The aim of the study was to evaluate whether, in men with prior negative prostate biopsies, systematic cores are also warranted at the time of an MRI-targeted repeat biopsy. We enrolled patients with prior negative biopsy undergoing real time MRI/TRUS fusion guided prostate biopsy at our institute between 2014 and 2016. Patients with at least one index lesion on multiparametric MRI were included. All eligible patients underwent both systematic random biopsies (12-14 cores) and targeted biopsies (2-4 cores). The study included 74 men with a median age of 65 years, PSA level of 9.27ng/mL, and prostatic volume of 45ml. The overall PCa detection rate and the clinically significant cancer detection rate were 56.7% and 39.2%, respectively. Targeted cores demonstrated similar clinically significant PCa detection rate compared to systematic cores (33.8% vs. 28.4%, P=0.38) with significantly less tissue sampling. Indeed, a combination approach was significantly superior to a targeted-only in overall PCa detection (+16.7% overall detection rate, P=0.007). Although differences in clinically significant PCa detection were statistically non-significant (P=0.13), a combination approach did allow detecting 7 extra clinically significant PCas (+13.8%). In patients with elevated PSA and prior negative biopsies, concurrent systematic sampling may be needed at the time of targeted biopsy in order to maximize PCa detection rate. Larger studies are needed to validate our findings. 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. On the symmetric α-stable distribution with application to symbol error rate calculations

    KAUST Repository

    Soury, Hamza; Alouini, Mohamed-Slim

    2016-01-01

    The probability density function (PDF) of the symmetric α-stable distribution is investigated using the inverse Fourier transform of its characteristic function. For general values of the stable parameter α, it is shown that the PDF

  2. Digital imaging improves upright stereotactic core biopsy of mammographic microcalcifications

    International Nuclear Information System (INIS)

    Whitlock, J.P.L.; Evans, A.J.; Burrell, H.C.; Pinder, S.E.; Ellis, I.O.; Blamey, R.W.; Wilson, A.R.M.

    2000-01-01

    AIM: This comparative study was carried out to assess the effect of using digital images compared to conventional film-screen mammography on the accuracy of core biopsy of microcalcifications using upright stereotactic equipment. MATERIALS AND METHODS: The biopsy results from a consecutive series of 104 upright stereotactic 14-gauge core biopsies performed with conventional X-ray (Group A) were compared with 40 biopsies carried out using stereotaxis with digital imaging (Group B). In all cases specimen radiography was performed and analysed for the presence of calcifications. Pathological correlation was then carried out with needle and surgical histology. RESULTS: The use of digital add-on equipment increased the radiographic calcification retrieval rate from 55 to 85% (P < 0.005). The absolute sensitivity of core biopsy in pure ductal carcinoma in situ (DCIS) cases rose from 34 to 69% (P < 0.03), with the complete sensitivity increasing from 52 to 94% (P < 0.005). For DCIS with or without an invasive component the absolute sensitivity rose from 41 to 67% (P = 0.052), while the complete sensitivity was 59% before and 86% after the introduction of digital imaging (P < 0.04). CONCLUSION: Digital equipment improves the performance of upright stereotactic core biopsy of microcalcifications, giving a significantly increased success rate in accurately obtaining calcifications. This leads to an improvement in absolute and complete sensitivity of core biopsy when diagnosing DCIS. Whitlock, J.P.L. (2000)

  3. Evaluation of lymphocytic exudative pleural effusion with pleural biopsy

    International Nuclear Information System (INIS)

    Khurram, M.; Jaffery, A.H.; Khar, Hamama-tul-Bushra; Malik, M.F.; Javed, S.; Burki, U.F.; Khan, B.A.; Ali, A.

    2002-01-01

    Objective: Evaluation of lymphocytic exudative pleural effusion by histopathological examination of pleural biopsy in patients with suspected tuberculous or malignant pleural effusion. Place and Duration of Study: The study was conducted at Pulmonology Department, Pakistan Institute of Medical Sciences, Islamabad and DHQ Teaching Hospital, Rawalpindi for two years 1999-2000. Subjects and Methods: A total of 120 patients with exudative pleural effusion underwent closed pleural biopsy with Abram's needle in standard way. Average 4 biopsy specimens were obtained in each patient which were examined histopathologically. Patients in whom a definite diagnosis was not possible were further investigated with repeat pleural biopsy, sputum examinations, bronchoscopy etc. Results definite histopathological diagnosis with pleural biopsy was possible in 59 (49.16% patients, including 13 diagnosed on repeat pleural biopsy. Two commonest diagnoses made were tuberculosis and adenocarcinoma, 64.40% and 13.55% respectively. Conclusion: Histopathological evaluation of pleural biopsy specimens can lead to diagnosis in 49.16% patients with exudative lymphocytic pleural effusion. (author)

  4. Mammotome HH biopsy - the future of minimal invasive breast surgery?

    International Nuclear Information System (INIS)

    Pietrzyk, G.; Nowicki, J.; Bojarski, B.; Kedzierski, B.; Wysocki, A.; Prudlak, E.

    2007-01-01

    Vacuum-assisted breast biopsy / Mammotome HH '' R '' Breast Biopsy System/ is the milestone in the diagnosis of breast lesions. This system has proven to be as diagnostically reliable as open surgery, but without scarring, deformations and hospitalizations associated with an open procedure. The aim of our study was to assess the role and possibilities of using this biopsy in treatment of benign breast lesions like fibroadenoma. From 2001 to 2004, about 1118 Mammotome biopsies were performed in our Department. Among 445 Mammotome biopsies performed under US control there were 211 cases of fibroadenomas. Follow-up was performed in 156 patients with this result at 6 and 12 months after biopsy. In our study we took into considerations the size, localizations as well as performers. In 2002 there were 70.8% patients with total lesion excision, 16.7% with residual lesion and 12.5% women with hematomas or scars. In 2003-2004 there were more women with total lesion excision (84.3%), fewer residual tumors and other lesions. In future, Mammotome breast biopsy can replace scalpel, and will become an alternative method to open surgical excision of fibroadenomas. It is important especially in the cases of young women to prevent cosmetic deformations and scars. (author)

  5. Sentinel lymph node biopsy in local recurrence of cutaneous melanoma

    International Nuclear Information System (INIS)

    Junqueira, G. Jr.; Bodanese, B.; Boff, M.F.; Espindola, M.B.; Haack, R.L.; Frigeri, C.D.L.

    2004-01-01

    Full text: Locally recurrent disease in patients with melanoma is usually defined as cutaneous or subcutaneous arising within 5 cm of the primary site after complete excision of the primary lesion. It may represent residual disease not excised with the primary tumor or the outgrowth of the satellite lesions, which are common with melanoma. Lymphatic mapping and sentinel lymph node (SLN) biopsy is highly accurate in staging nodal basins at risk of regional metastases in primary melanoma patients and identifies those who may benefit from earlier lymphadenectomy. Our purpose was to evaluate the efficacy of sentinel lymph node mapping and biopsy in local recurrence of cutaneous melanoma when the primary lesion was less than 1.0mm thick. Three patients with local recurrence of cutaneous melanoma underwent sentinel lymph node mapping and biopsy. All patients underwent preoperative lymphoscintigraphy to identify the lymphatic basin and the site of the sentinel node. All patients subsequently underwent intra-operative lymphatic mapping and selective lymph node biopsy with vital blue dye and hand-held gamma probe. Excised SLN were analysed by conventional histological staining (H and E) and immunohistochemical staining. In all patients the lymphatic mapping and sentinel lymph node biopsy was successful. The SLN biopsy was negative in two patients and positive in one who underwent therapeutic lymph node dissection. Our results indicate that the SLN mapping and biopsy is also possible in patients having local recurrence of cutaneous melanoma. Although long-term results are not available, early results are promising. (author)

  6. Superficial biopsy of the cervix: new technique

    Directory of Open Access Journals (Sweden)

    Ettore De Girolami

    2002-06-01

    Full Text Available Cytological examination of the cervix in all patients is considered a necessity. A new technique of superficial biopsy is described and advantages en. numeratedEl Autor presenta una nueva técnica para biopsia superficial, considerando la necesidad de hacer rutinariamente a todas las pacientes el examen citológico del cérvix. La muestra se toma con el extremo de un aplicador cubierto de gaza. Este dispositivo, humedecido previamente en una solución de etanol, metanol y éter etílico, se aplica inmediatamente al cérvix del útero y, dándole un movimiento como el de las manecillas del reloj, se toma la muestra con la que se hacen frotis por aposición que se colorean por el método de Giemsa. Esta técnica ofrece la ventaja de que el tejido en estudio se adhiere perfectamente a la gaza, la cual, con el movimiento de rotación, desprende las células del "os uteri", las que son fijadas al mismo tiempo. La preparación del dispositivo es sumamente sencilla. La prueba resulta de bajo costo como de breve y fácil realizaciónL' Autore prende in considerazione l'utilitá dell' esame citologico del collo dell'utero, fatto rutinariamente a tutte le pazienti. Si descrive una nuova tecnica di biopsia superficiale che oltfe ad offrire dei vantaggi é di poca spesa e si puó eseguire con facilitá ed in breve tempo

  7. Sentinel lymph node biopsy: clinical relevance

    International Nuclear Information System (INIS)

    Howman-Giles, R.

    2002-01-01

    Sentinel lymph node biopsy (SLNB) has become an important technique in the management of patients with intermediate level melanoma, clinical operable breast cancer and some other cancers. The technique relies on lymphatic mapping to define the lymph drainage from a primary tumour with the premise that the lymph nodes, which directly drain from that area, will reflect the tumour status of the remainder of the node field. Current techniques use lymphoscintigraphy where a radioactive labelled particle and / or blue dye are injected intradermally or intraparenchymally to map the lymph drainage, often in conjunction with a radioactive gamma probe at surgery. In patients with melanoma the SLNB has improved the staging and prognostic information by more accurate determination of whether regional lymph nodes have metastatic spread. This has a major impact on patient management as those patients with negative nodes do not require regional lymph node dissection and have a significantly better prognosis. In our experience of over 3000 patients the combined sentinel node biopsy technique localised accurately 98% of sentinel lymph nodes. Lymphoscintigraphy in patients with melanoma to locate the sentinel lymph nodes involves the intradermal injection of a radiocolloid around the melanoma site or the excision biopsy site. Injections of 5 -10 MBq in 0.05-0.1ml/inj are used and typically 4 injections are usually required. Following tracer injection dynamic imaging is performed to follow the lymphatic collecting vessels until they reach the draining sentinel nodes. An image should be acquired as the vessels reach the node field so that the sentinel nodes directly receiving the channels can be identified and distinguished from any second tier nodes which may sometimes be seen. Delayed scans are performed 2 hours later at which time all regions which can possible drain the primary melanoma site are examined with 5-10 minute static images. The surface location of all sentinel nodes is

  8. Does Prebiopsy, Nonsterile Ultrasonography Gel Affect Biopsy-Site Asepsis?

    International Nuclear Information System (INIS)

    Gurel, Kamil; Karabay, Oguz; Gurel, Safiye; Hildebolt, Charles

    2008-01-01

    Purpose. The purpose of this study was to determine the extent to which the use of nonsterile gel, prior to antiseptic procedures in ultrasonography (US)-guided percutaneous biopsies, results in contamination of the biopsy site. Materials and Methods. Patients referred for US-guided percutaneous biopsies were included in this study. Transmission material used for US evaluation before biopsy-site antiseptic procedures were performed was either nonsterile gel or sterile saline. Patients were randomly assigned to two groups: nonsterile gel (n = 30) and sterile saline (n = 30). Before the transmission material was used and after antiseptic procedures were performed, microbial swabs of a 10-cm 2 -diameter area were obtained at the biopsy site. Swabs were also obtained from the gel, saline, and povidine-iodine. Inoculated specimen plates were incubated at 37 o C under aerobic conditions, and the numbers of colony-forming units recorded. Nominal logistic regression analysis was used to calculate the odds of postantisepsis bacterial growth (after antiseptic procedures were performed) based on group, gender, coincidental disease (diabetes, chronic renal failure, and malignancy), biopsy-site location (head and neck or breast and abdomen), and local factors (skin fold, skin tag, and hair). Results. The following odds ratios (adjusted for the other variables) and their 95% confidence intervals were calculated: (1) group (2.9 [0.8-11.1]; p = 0.10); (2) gender (1.2 [0.3-5.2]; p = 0.78); (3) coincidental disease (7.6 [0.9-166.7]; p = 0.09); (4) biopsy site location (6.2 [1.4-31.3]; p = 0.02); and (5) local factors (7.0 [1.6-36.0]; p = 0.01). No bacterial growth occurred with swabs obtained from gel, povidine-iodine, or saline. Conclusion. We conclude that nonsterile gel used prior to percutaneous biopsy does not affect biopsy-site asepsis

  9. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  10. Percutaneous biopsy of the synovial membrane of large joints

    International Nuclear Information System (INIS)

    Begule, V.

    1989-01-01

    Using flouroscopy, the authors have developed new techniques of percutaneous synovial biopsy (PSB) of large joints of limbs (other than the knee). PSB was performed on outpatients under local anesthesia. They have performed 84 biopsies (hips: 57), shoulders: 10, elbows: six, wrists: five, ankles: six). The PSB technique was gradually improved. Main technical refinements were use of a Tru-Cut needle introduced through a Jamshidi trephine needle, placement of the cutting window parallel to the anterior aspect of the joint, and selection of an optimal approach and biopsy site. With these improvements, the success rate of attaining synovial membrane was raised from 49% to 81%. No complications were encountered

  11. Magnetic-resonance-guided biopsy of focal liver lesions

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Ethan A. [University of Michigan Health System, Section of Pediatric Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); Grove, Jason J. [University of Michigan Health System, Division of Interventional Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); Der Spek, Abraham F.L.V. [University of Michigan Health System, Department of Anesthesiology, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States); Jarboe, Marcus D. [University of Michigan Health System, Division of Interventional Radiology, C.S. Mott Children' s Hospital, Department of Radiology, Ann Arbor, MI (United States); University of Michigan Health System, Section of Pediatric Surgery, C.S. Mott Children' s Hospital, Department of Surgery, Ann Arbor, MI (United States)

    2017-05-15

    Image-guided biopsy techniques are widely used in clinical practice. Commonly used methods employ either ultrasound (US) or computed tomography (CT) for image guidance. In certain patients, US or CT guidance may be suboptimal, or even impossible, because of artifacts, suboptimal lesion visualization, or both. We recently began performing magnetic resonance (MR)-guided biopsy of focal liver lesions in select pediatric patients with lesions that are not well visualized by US or CT. This report describes our experience performing MR-guided biopsy of focal liver lesions, with case examples to illustrate innovative techniques and novel aspects of these procedures. (orig.)

  12. Implementation of Upright Digital Breast Tomosynthesis-guided Stereotactic Biopsy.

    Science.gov (United States)

    Omofoye, Toma S; Martaindale, Sarah; Teichgraeber, Davis C; Parikh, Jay R

    2017-11-01

    With growing adoption of digital breast tomosynthesis, an increasing number of imaging abnormalities are being identified only by tomosynthesis. Upright digital breast tomosynthesis-guided stereotactic biopsy is a proven method for sampling these abnormalities as well as abnormalities traditionally evaluated using conventional stereotactic biopsy. In this article, we describe the technique of upright digital breast tomosynthesis-guided stereotactic biopsy and outline a systematic operational approach to implementation of this technique in clinical radiology practices. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  13. The Importance of Biopsy in the Era of Molecular Medicine.

    Science.gov (United States)

    Ziv, Etay; Durack, Jeremy C; Solomon, Stephen B

    Recent advances in the molecular characterization of cancers have triggered interest in developing a new taxonomy of disease in oncology with the goal of using the molecular profile of a patient's tumor to predict response to treatment. Image-guided needle biopsy is central to this "precision medicine" effort. In this review, we first discuss the current role of biopsy in relation to clinical examples of molecular medicine. We then outline important bottlenecks to the advancement of precision medicine and highlight the potential role of image-guided biopsy to address these challenges.

  14. Image guided versus palpation guided core needle biopsy of palpable breast masses: a prospective study

    Directory of Open Access Journals (Sweden)

    Smriti Hari

    2016-01-01

    Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates.

  15. The diagnosis of cancer in thyroid fine needle aspiration biopsy. Surgery, repeat biopsy or specimen consultation?

    Directory of Open Access Journals (Sweden)

    Agata Stanek-Widera

    2016-05-01

    Full Text Available Fine needle aspiration biopsy (FNA is the only diagnostic method that allows a preoperative diagnosis of thyroid carcinoma. An unequivocal diagnosis of a malignant change is achievable only in cases in which all cytological criteria of carcinoma are met. The aim of the study was to evaluate the necessity of repeat thyroid FNA in patients with papillary thyroid carcinoma verified on consultative examination (CE. We analyzed cytology reports of thyroid FNA and CE that resulted in the diagnosis of papillary carcinoma. Evaluation of the correlation of the cytological diagnosis with the histopathology report was based on data obtained after the surgery. Between 2010 and 2015 in the Institute of Oncology (IO there were 184 cancers diagnosed on CE or in thyroid FNA performed primarily in IO. Additionally, 74 patients were subjected to repeat biopsy after confirmation of cancer in CE. Histopathological diagnosis of cancer was obtained in 62 (100% cases that were doubly confirmed with cytological examination. The remaining 12 patients were operated on outside the institute. From 110 FNA primarily performed in the IO, histopathological verification was achievable in 92 cases, from which 92 (100% provided a confirmation of cancer, and the remaining 18 patients were operated on outside the institute. High (100% specificity of cancer diagnosis in FNA established primarily and verified on CE (second independent assessment indicates that repeat FNA in order to confirm the diagnosis is unnecessary.

  16. Endoscopic trans-nasal approach for biopsy of orbital tumors using image-guided neuro-navigation system

    International Nuclear Information System (INIS)

    Sieskiewicz, A.; Mariak, Z.; Rogowski, M.; Lyson, T.

    2008-01-01

    Histopathological diagnosis of intraorbital tumors is of crucial value for planning further therapy. The aim of the study was to explore clinical utility of image-guided endoscopy for biopsy of orbital tumors. Trans-nasal endoscopic biopsy of intraorbital mass lesions was performed in 6 patients using a neuro-navigation system (Medtronic Stealth Station Treon plus). The CT and MRI 1 mm slice images were fused by the system in order to visualise both bony and soft tissue structures. The anatomic fiducial registration protocol was used during the procedure. All lesions were precisely localised and the biopsies could be taken from the representative part of the pathological mass. None of the patients developed aggravation of ocular symptoms after the procedure. The operative corridor as well as the size of orbital wall fenestration could be limited to a minimum. The accuracy of neuro-navigation remained high and stable during the entire procedure. The image-guided neuro-navigation system facilitated endoscopic localisation and biopsy of intraorbital tumors and contributed to the reduction of surgical trauma during the procedure. The technique was particularly useful in small, medially located, retrobulbar tumors and in unclear situations when the structure of the lesion resembled surrounding intraorbital tissue. (author)

  17. [When to ask for a skin biopsy in a patient with leg ulcer? Retrospective study of 143 consecutive biopsies].

    Science.gov (United States)

    Stansal, A; Khayat, K; Duchatelle, V; Tella, E; Gautier, V; Sfeir, D; Attal, R; Lazareth, I; Priollet, P

    2018-02-01

    A vascular cause is found in around 85% of leg ulcer patients, but non-vascular causes are also observed. Their diagnosis is based on a set of clinical arguments and skin biopsy with histological analysis. The aim of this study was to analyze the results of these biopsies and to find common criteria for ulcers whose skin biopsies had led to the diagnosis of a non-vascular ulcer. A retrospective study was carried out on the analysis of 143 skin biopsies of leg ulcers. The reasons for the biopsy were mainly atypical clinical signs and/or the lack of improvement in care after 6 months, as advocated by the French health authorities. The skin biopsies led to a diagnosis of non-vascular ulcer in 4.9% of cases (7/143), including skin cancer (n=5, 3.5%), cutaneous leishmaniasis (n=1, 0.7%) and Pyoderma gangrenosum (n=1, 0.7%). The univariate statistical analysis revealed that an elevated rim and abnormal excessive granulation tissue were significantly more frequently found in these ulcers. All patients with a positive skin biopsy had associated vascular involvement. This study found a 5% rate of non-vascular causes of ulcers, mainly skin cancer. Elevated rims and abnormal excessive granulation tissue were the unusual features most commonly found in these ulcers. All patients whose skin biopsy revealed a non-vascular cause had associated vascular involvement. This information confirms the need to perform a skin biopsy, even in the presence of a vascular disease. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  18. The single-biopsy approach in determining protein synthesis in human slow-turning-over tissue: use of flood-primed, continuous infusion of amino acid tracer

    DEFF Research Database (Denmark)

    Holm, Lars; Reitelseder, Søren; Dideriksen, Kasper

    2014-01-01

    Muscle protein synthesis (MPS) rate is determined conventionally by obtaining two or more tissue biopsies during a primed, continuous infusion of a stable isotopically labeled amino acid. The purpose of the present study was to test whether tracer priming given as a flooding dose, thereby securing....... In conclusion, the flood-primed, continuous infusion protocol using phenylalanine as tracer can validly be used to measure the protein synthesis rate in human in vivo experiments by obtaining only a single tissue biopsy after a prolonged infusion period....

  19. On The Roman Domination Stable Graphs

    Directory of Open Access Journals (Sweden)

    Hajian Majid

    2017-11-01

    Full Text Available A Roman dominating function (or just RDF on a graph G = (V,E is a function f : V → {0, 1, 2} satisfying the condition that every vertex u for which f(u = 0 is adjacent to at least one vertex v for which f(v = 2. The weight of an RDF f is the value f(V (G = Pu2V (G f(u. The Roman domination number of a graph G, denoted by R(G, is the minimum weight of a Roman dominating function on G. A graph G is Roman domination stable if the Roman domination number of G remains unchanged under removal of any vertex. In this paper we present upper bounds for the Roman domination number in the class of Roman domination stable graphs, improving bounds posed in [V. Samodivkin, Roman domination in graphs: the class RUV R, Discrete Math. Algorithms Appl. 8 (2016 1650049].

  20. Nephrogenic systemic fibrosis: Review of 408 biopsy-confirmed cases

    Directory of Open Access Journals (Sweden)

    Zhitong Zou

    2011-01-01

    Full Text Available Nephrogenic systemic fibrosis (NSF has now been virtually eliminated by the discovery of its association with gadolinium-based contrast agents (GBCAs and the consequent reduced use of GBCA-enhanced magnetic resonance imaging (MRI in severe renal failure patients. This review of 408 biopsy-confirmed cases shows how to minimize NSF risk when performing GBCA-enhanced MRI or magnetic resonance angiography. The absence of any NSF cases in patients less than 8 years old or greater than 87 years old suggests that infants and elderly patients are already protected. Limiting GBCA dose to a maximum of 0.1 mMol/kg, dialyzing dialysis patients quickly following GBCA administration, delaying administration of GBCA in acute renal failure until after renal function returns or dialysis is initiated, and avoiding nonionic linear GBCA in renal failure patients, especially when there are pro-inflammatory conditions, appear to have reduced NSF risk to the point where safe GBCA-enhanced MRI is possible in most patients.

  1. [Gene expression analyses of kidney biopsies: the European renal cDNA bank--Kröner-Fresenius biopsy bank].

    Science.gov (United States)

    Cohen, C D; Kretzler, M

    2009-03-01

    Histological analysis of kidney biopsies is an essential part of our current diagnostic workup of patients with renal disease. Besides the already established diagnostic tools, new methods allow extensive analysis of the sample tissue's gene expression. Using results from a European multicenter study on gene expression analysis of renal biopsies, in this review we demonstrate that this novel approach not only expands the scope of so-called basic research but also might supplement future biopsy diagnostics. The goals are improved diagnosis and more specific therapy choice and prognosis estimates.

  2. Influence of horse stable environment on human airways.

    Science.gov (United States)

    Elfman, Lena; Riihimäki, Miia; Pringle, John; Wålinder, Robert

    2009-05-25

    Many people spend considerable amount of time each day in equine stable environments either as employees in the care and training of horses or in leisure activity. However, there are few studies available on how the stable environment affects human airways. This study examined in one horse stable qualitative differences in indoor air during winter and late summer conditions and assessed whether air quality was associated with clinically detectable respiratory signs or alterations to selected biomarkers of inflammation and lung function in stable personnel. The horse stable environment and stable-workers (n = 13) in one stable were investigated three times; first in the winter, second in the interjacent late summer and the third time in the following winter stabling period. The stable measurements included levels of ammonia, hydrogen sulphide, total and respirable dust, airborne horse allergen, microorganisms, endotoxin and glucan. The stable-workers completed a questionnaire on respiratory symptoms, underwent nasal lavage with subsequent analysis of inflammation markers, and performed repeated measurements of pulmonary function. Measurements in the horse stable showed low organic dust levels and high horse allergen levels. Increased viable level of fungi in the air indicated a growing source in the stable. Air particle load as well as 1,3-beta-glucan was higher at the two winter time-points, whereas endotoxin levels were higher at the summer time-point. Two stable-workers showed signs of bronchial obstruction with increased PEF-variability, increased inflammation biomarkers relating to reported allergy, cold or smoking and reported partly work-related symptoms. Furthermore, two other stable-workers reported work-related airway symptoms, of which one had doctor's diagnosed asthma which was well treated. Biomarkers involved in the development of airway diseases have been studied in relation to environmental exposure levels in equine stables. Respirable dust and 1

  3. Influence of horse stable environment on human airways

    Directory of Open Access Journals (Sweden)

    Pringle John

    2009-05-01

    Full Text Available Abstract Background Many people spend considerable amount of time each day in equine stable environments either as employees in the care and training of horses or in leisure activity. However, there are few studies available on how the stable environment affects human airways. This study examined in one horse stable qualitative differences in indoor air during winter and late summer conditions and assessed whether air quality was associated with clinically detectable respiratory signs or alterations to selected biomarkers of inflammation and lung function in stable personnel. Methods The horse stable environment and stable-workers (n = 13 in one stable were investigated three times; first in the winter, second in the interjacent late summer and the third time in the following winter stabling period. The stable measurements included levels of ammonia, hydrogen sulphide, total and respirable dust, airborne horse allergen, microorganisms, endotoxin and glucan. The stable-workers completed a questionnaire on respiratory symptoms, underwent nasal lavage with subsequent analysis of inflammation markers, and performed repeated measurements of pulmonary function. Results Measurements in the horse stable showed low organic dust levels and high horse allergen levels. Increased viable level of fungi in the air indicated a growing source in the stable. Air particle load as well as 1,3-β-glucan was higher at the two winter time-points, whereas endotoxin levels were higher at the summer time-point. Two stable-workers showed signs of bronchial obstruction with increased PEF-variability, increased inflammation biomarkers relating to reported allergy, cold or smoking and reported partly work-related symptoms. Furthermore, two other stable-workers reported work-related airway symptoms, of which one had doctor's diagnosed asthma which was well treated. Conclusion Biomarkers involved in the development of airway diseases have been studied in relation to

  4. GoM Coastal and Estuarine Biopsy Surveys

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Small vessel surveys are conducted within estuarine and nearshore coastal waters to collect tissue biopsy samples from bottlenose dolphins. Visual surveys are...

  5. Percutaneous needle-biopsy of the adrenal glands

    International Nuclear Information System (INIS)

    Wernecke, K.; Galanski, M.

    1986-01-01

    This account of techniques, range of indications and results of percutaneous adrenal biopsy refers to communications in the literature and to the authors' own experience. Lateral, transhepatic aspiration of adrenal material guided by sonographic control is more easy in the right adrenal gland. Punctation of the left adrenal gland ought to be done from the back and guided by computerized tomography, also in order to leave spleen, kidney, pancreas and stomach as unaffected as possible. The most frequent problem indicating adrenal biopsy still is differentiation between metastases or encretorily non-active adenomas in tumor patients. Experienced examiners will achieve an 80 to 90% sensitivity of adrenal biopsy. Clinically established, suspected phaeochromocytoma is an absolute contra-indication to fine-needle biopsy. (orig./MG) [de

  6. Grading of shoulder ulcerations in sows by biopsies

    DEFF Research Database (Denmark)

    Jensen, Henrik Elvang; Dahl-Pedersen, Kirstin; Barington, Krisitane

    2014-01-01

    legislation, stating that sows with shoulder ulcers grade 3 or 4 must be kept loose and have access to soft bedding. Thus, the aim of the present study was to evaluate if biopsies from the center of a shoulder ulcer can be used to point out animals for which an intervention must be initiated. Postmortem......, a punch biopsy was sampled from the center of the ulceration or from the tissue overlaying the tuber spina scapula. Afterward, the shoulders were cross-sectioned and evaluated grossly and histologically (“gold standard”). In total, 121 shoulders were included in the study, and the diagnostic value...... of a punch biopsy in grading shoulder ulcerations was evaluated. The results showed a sensitivity of 0.78, a specificity of 0.98, a positive likelihood ratio of 38.36, and a negative likelihood ratio of 0.22. The agreement between the cross-section evaluation and the punch biopsy was found to be 0...

  7. Breast Biopsy: The Effects of Hypnosis and Music.

    Science.gov (United States)

    Téllez, Arnoldo; Sánchez-Jáuregui, Teresa; Juárez-García, Dehisy M; García-Solís, Manuel

    2016-01-01

    The authors evaluated the efficacies of audio-recorded hypnosis with background music and music without hypnosis in the reduction of emotional and physical disturbances in patients scheduled for breast biopsy in comparison with a control group. A total of 75 patients were randomly assigned to 3 different groups and evaluated at baseline and before and after breast biopsy using visual analog scales of stress, pain, depression, anxiety, fatigue, optimism, and general well-being. The results showed that, before breast biopsy, the music group presented less stress and anxiety, whereas the hypnosis with music group presented reduced stress, anxiety, and depression and increased optimism and general well-being. After the biopsy, the music group presented less anxiety and pain, whereas the hypnosis group showed less anxiety and increased optimism.

  8. Percutaneous Biopsy of Retrobulbar Masses: Anatomical Considerations and MRI Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Edalat, Faramarz, E-mail: faramarz.edalat@gmail.com; Cazzato, Roberto Luigi; Garnon, Julien; Tsoumakidou, Georgia [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France); Avérous, Gerlinde [CHU Strasbourg Hautepierre, Department of Pathology (France); Caudrelier, Jean; Koch, Guillaume; Gangi, Afshin [Nouvel Hôpital Civil (Hôpitaux Universitaires de Strasbourg, HUS), Department of Interventional Radiology (France)

    2017-04-15

    PurposeObtaining adequate tissue from retrobulbar masses remains a challenge. To this end, a new method of retrobulbar mass biopsy using MRI guidance is presented.Materials and MethodsTwo patients (7- and 71-year-old male) with indeterminate retrobulbar masses underwent bioptic and cytological samplings using MR-compatible 18G and 20–22G needles, and multi-planar MR fluoroscopy. An inferior approach was taken to avoid injury to the optic nerve and ophthalmic arteries.ResultsThe two biopsies were completed without complication. The core biopsy resulted in a final diagnosis, whereas the cytological sampling was non-diagnostic.ConclusionPercutaneous MR-guided retrobulbar mass biopsy proved to be feasible and safe in the two cases described in this report.

  9. Processing of nerve biopsies: a practical guide for neuropathologists.

    NARCIS (Netherlands)

    Weis, J.; Brandner, S.; Lammens, M.M.Y.; Sommer, C.; Vallat, J.M.

    2012-01-01

    Nerve biopsy is a valuable tool in the diagnostic work-up of peripheral neuropathies. Currently, major indications include interstitial pathologies such as suspected vasculitis and amyloidosis, atypical cases of inflammatory neuropathy and the differential diagnosis of hereditary neuropathies that

  10. Antibiotic prophylaxis and complications following prostate biopsies - a systematic review

    DEFF Research Database (Denmark)

    Klemann, Nina; Helgstrand, John Thomas; Brasso, Klaus

    2017-01-01

    of the first dose of antibiotic, one study found that administration 24 h before biopsy versus administration immediately before reduced the relative risk of post-biopsy infection by 55%. Seven studies compared different durations of antibiotic prophylaxis. None showed any benefit from continuing prophylaxis......INTRODUCTION: Transrectal ultrasound-guided biopsies (TRUS-gb) are associated with both mild and serious complications. Prophylactic antibiotics reduce the risk of septicaemia and mortality; however, no international consensus exists on the timing and duration of antibiotics, including the optimal...... drug strategy. We reviewed the current evidence supporting use of prophylactic antibiotics and the risk of complications following prostate biopsies. METHODS: This review was drafted in accordance with the Prisma Guidelines. The PubMed, Embase and Cochrane databases were searched. RESULTS: A total...

  11. Fatal mediastinal biopsy: How interventional radiology saves the day

    Directory of Open Access Journals (Sweden)

    Y Yaacob

    2012-01-01

    Full Text Available This was a case of a 35-year-old man with mediastinal mass requiring computed tomography (CT-guided biopsy for tissue diagnosis. A posterior approach with an 18-gauge biopsy needle was used to obtain tissue sample. Post biopsy, patient condition deteriorated and multiphase CT study detected active bleeding in arterial phase at the biopsy site with massive hemothorax. Subsequent angiography showed arterial bleeder arising from the apical branch of the right pulmonary artery. Selective endovascular embolization with NBCA (n-Butyl cyanoacrylate was successful. Patient survived the complication. The case highlighted a rare complication in a common radiology procedure and the value of the interventional radiology unit in avoiding a fatal outcome.

  12. Parotid Gland Biopsy, the Alternative Way to Diagnose Sjogren Syndrome

    NARCIS (Netherlands)

    Spijkervet, Fred. K.L.; Haacke, Erlin; Kroese, Frans G. M.; Bootsma, Hendrika; Vissink, Arjan

    Salivary gland biopsy is a technique broadly applied for the diagnosis of Sjogren syndrome (SS), lymphoma in SS, and connective tissue disorders (sarcoidosis, amyloidosis). In SS characteristic histology findings are found, including lymphocytic infiltration surrounding the excretory ducts in

  13. The value of percutaneous trephine biopsy in the diagnosis of ...

    African Journals Online (AJOL)

    1991-01-05

    Jan 5, 1991 ... the diagnosis of lesions of the vertebral column. 1. ODENDAAL, L. B. ... the initial radiographs and the differential diagnosis formulated from these appropriate .... cenain imponant points. A Jamshidi bone biopsy trocar and.

  14. Biopsy results of Bosniak 2F and 3 cystic lesions

    DEFF Research Database (Denmark)

    Rasmussen, René; Hørlyck, Arne; Nielsen, Tommy Kjærgaard

    be helpful in clinical decisions. Material and Methods: From March 2013 - December 2014 a total of 295 percutaneous ultrasound guided biopsies from 287 patients with a suspected malignant renal lesion were performed at our institution. All cases were reviewed in PACS by (RR) and lesions presenting...... with a cystic change were re-evaluated and re-categorized after the Bosniak classification system. The re-evaluation and re-categorization was performed in consensus by a junior radiologist (RR) and an uro-radiological expert (OG). Results: Biopsies from eighteen Bosniak 2F cystic lesions were pathologically...... analyzed and three (17%) proved to be malignant. Biopsies from seventeen Bosniak 3 cystic lesions were pathologically analyzed and five (29%) were found to be malignant. Conclusion: Our results reveal a considerable malignancy rate among both Bosniak 2F and 3 cystic renal lesions. Biopsy seems...

  15. Comparison between preoperative biopsy and post-excision ...

    African Journals Online (AJOL)

    Comparison between preoperative biopsy and post-excision histology results in sarcoma: Experience at Chris Hani Baragwanath Academic Hospital, Johannesburg, South Africa. KG Panda, MJ Hale, D Kruger, TE Luvhengo ...

  16. Sentinel lymph node biopsy: An audit of intraoperative assessment ...

    African Journals Online (AJOL)

    2015-07-02

    Jul 2, 2015 ... Sentinel lymph node biopsy: An audit of ... cytotechnology service ... To audit results from intraoperative assessment of sentinel lymph node ..... out, and turnaround time in gynecologic cytology quality assurance: Findings.

  17. Computed tomography - guided cutting needle biopsy of pulmonary lesions

    International Nuclear Information System (INIS)

    Liao Shin Yu; Deheinzelin, Daniel; Younes, Riad N.; Chojniak, Rubens

    2002-01-01

    The purpose of this study was to report the experience of a radiology department in the use of computed tomography-guided cutting needle biopsy of pulmonary nodules, by evaluating diagnostic yield and incidence of complications. This is a retrospective analysis of 52 consecutive patients who underwent lung lesion biopsy guided by computed tomography, performed between May 1997 and May 2000. Thirty-five patients were male and 17 were female, with ages ranging from 5 to 85 years (median, 62 years). The size of the lesions ranged from 1.8 to 15 cm (median, 5.4 cm). In a total of 52 biopsies of lung lesions, 51 biopsies (98.1%) supplied appropriate material for histopathological diagnosis, with 9 diagnosed (17.3%) as benign and 42 (80.8%) as malignant lesions. Specific diagnosis was obtained in 44 (84.6%) biopsies: 4 benign (9.1%) and 40 (90.9%) malignant lesions. The sensitivity, specificity, and accuracy of the cutting needle biopsies for determining presence of malignancy were 96.8%, 100%, and 97.2%, respectively. Complications occurred in 9 cases (17.3%), including 6 cases (11.5%) of small pneumothorax, 1 (1.9%) of hemoptysis, 1 (1.9%) of pulmonary hematoma, and 1 (1.9%) of thoracic wall hematoma. All had spontaneous resolution. There were no complications requiring subsequent intervention. The high sensitivity and specificity of the method and the low rate of complications have established cutting needle biopsy as an efficient and safe tool for the diagnosis of lung lesions. In our hospital, cutting needle biopsy is considered a reliable procedure for the evaluation of indeterminate pulmonary nodules. (author)

  18. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    International Nuclear Information System (INIS)

    Kim, You Me; Park, Hee Boong; Ryu, Jin Woo

    2005-01-01

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images

  19. Diagnosing pancreatic cancer: the role of percutaneous biopsy and CT

    International Nuclear Information System (INIS)

    Amin, Z.; Theis, B.; Russell, R.C.G.; House, C.; Novelli, M.; Lees, W.R.

    2006-01-01

    Aims: To determine the sensitivity and complications of percutaneous biopsy of pancreatic masses, and whether typical computed tomography (CT) features of adenocarcinoma can reliably predict this diagnosis. Materials and methods: A 5 year retrospective analysis of percutaneous core biopsies of pancreatic masses and their CT features was undertaken. Data were retrieved from surgical/pathology databases; medical records and CT reports and images. Results: Three hundred and three patients underwent 372 biopsies; 56 of 87 patients had repeat biopsies. Malignancy was diagnosed in 276 patients, with ductal adenocarcinoma in 259 (85%). Final sensitivity of percutaneous biopsy for diagnosing pancreatic neoplasms was 90%; for repeat biopsy it was 87%. Complications occurred in 17 (4.6%) patients, in three of whom the complications were major (1%): one abscess, one duodenal perforation, one large retroperitoneal bleed. CT features typical of ductal adenocarcinoma were: hypovascular pancreatic mass with bile and/or pancreatic duct dilatation. Atypical CT features were: isodense or hypervascular mass, calcification, non-dilated ducts, cystic change, and extensive lymphadenopathy. Defining typical CT features of adenocarcinoma as true-positives, CT had a sensitivity of 68%, specificity of 95%, positive predictive value (PPV) of 98%, and negative predictive value of 41% for diagnosing pancreatic adenocarcinoma. Conclusion: Final sensitivity of percutaneous biopsy for establishing the diagnosis was 90%. CT features typical of pancreatic adenocarcinoma had high specificity and PPV. On some occasions, especially in frail patients with co-morbidity, it might be reasonable to assume a diagnosis of pancreatic cancer if CT features are typical, and biopsy only if CT shows atypical features

  20. Pericardial Tamponade Following CT-Guided Lung Biopsy

    International Nuclear Information System (INIS)

    Mitchell, Michael J.; Montgomery, Mark; Reiter, Charles G.; Culp, William C.

    2008-01-01

    While not free from hazards, CT-guided biopsy of the lung is a safe procedure, with few major complications. Despite its safety record, however, potentially fatal complications do rarely occur. We report a case of pericardial tamponade following CT-guided lung biopsy. Rapid diagnosis and therapy allowed for complete patient recovery. Physicians who perform this procedure should be aware of the known complications and be prepared to treat them appropriately.

  1. THE DIAGNOSIS OF LIVER ALLOGRAFT ACUTE REJECTION IN LIVER BIOPSIES

    Directory of Open Access Journals (Sweden)

    L. V. Shkalova

    2011-01-01

    Full Text Available We performed histological examination of 80 liver allograft biopsies, the diagnosis of acute rejection was proved in 34 cases. Histological changes in liver biopsies in different grades of acute rejection were estimated according to Banff classification 1995, 1997 and were compared with current literature data. The article deals with the question of morphological value of grading acute rejection on early and late, also we analyze changes in treat- ment tactics after morphological verification of liver allograft acute rejection. 

  2. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Me [Dankook University Hospital, Seoul (Korea, Republic of); Park, Hee Boong [Park Breast Clinic, Seoul (Korea, Republic of); Ryu, Jin Woo [Cheonan Choongmu Hospital, Cheonan (Korea, Republic of)

    2005-08-15

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images.

  3. Reoperative sentinel lymph node biopsy after previous mastectomy.

    Science.gov (United States)

    Karam, Amer; Stempel, Michelle; Cody, Hiram S; Port, Elisa R

    2008-10-01

    Sentinel lymph node (SLN) biopsy is the standard of care for axillary staging in breast cancer, but many clinical scenarios questioning the validity of SLN biopsy remain. Here we describe our experience with reoperative-SLN (re-SLN) biopsy after previous mastectomy. Review of the SLN database from September 1996 to December 2007 yielded 20 procedures done in the setting of previous mastectomy. SLN biopsy was performed using radioisotope with or without blue dye injection superior to the mastectomy incision, in the skin flap in all patients. In 17 of 20 patients (85%), re-SLN biopsy was performed for local or regional recurrence after mastectomy. Re-SLN biopsy was successful in 13 of 20 patients (65%) after previous mastectomy. Of the 13 patients, 2 had positive re-SLN, and completion axillary dissection was performed, with 1 having additional positive nodes. In the 11 patients with negative re-SLN, 2 patients underwent completion axillary dissection demonstrating additional negative nodes. One patient with a negative re-SLN experienced chest wall recurrence combined with axillary recurrence 11 months after re-SLN biopsy. All others remained free of local or axillary recurrence. Re-SLN biopsy was unsuccessful in 7 of 20 patients (35%). In three of seven patients, axillary dissection was performed, yielding positive nodes in two of the three. The remaining four of seven patients all had previous modified radical mastectomy, so underwent no additional axillary surgery. In this small series, re-SLN was successful after previous mastectomy, and this procedure may play some role when axillary staging is warranted after mastectomy.

  4. Diagnosing pancreatic cancer: the role of percutaneous biopsy and CT

    Energy Technology Data Exchange (ETDEWEB)

    Amin, Z.; Theis, B.; Russell, R.C.G.; House, C.; Novelli, M.; Lees, W.R

    2006-12-15

    Aims: To determine the sensitivity and complications of percutaneous biopsy of pancreatic masses, and whether typical computed tomography (CT) features of adenocarcinoma can reliably predict this diagnosis. Materials and methods: A 5 year retrospective analysis of percutaneous core biopsies of pancreatic masses and their CT features was undertaken. Data were retrieved from surgical/pathology databases; medical records and CT reports and images. Results: Three hundred and three patients underwent 372 biopsies; 56 of 87 patients had repeat biopsies. Malignancy was diagnosed in 276 patients, with ductal adenocarcinoma in 259 (85%). Final sensitivity of percutaneous biopsy for diagnosing pancreatic neoplasms was 90%; for repeat biopsy it was 87%. Complications occurred in 17 (4.6%) patients, in three of whom the complications were major (1%): one abscess, one duodenal perforation, one large retroperitoneal bleed. CT features typical of ductal adenocarcinoma were: hypovascular pancreatic mass with bile and/or pancreatic duct dilatation. Atypical CT features were: isodense or hypervascular mass, calcification, non-dilated ducts, cystic change, and extensive lymphadenopathy. Defining typical CT features of adenocarcinoma as true-positives, CT had a sensitivity of 68%, specificity of 95%, positive predictive value (PPV) of 98%, and negative predictive value of 41% for diagnosing pancreatic adenocarcinoma. Conclusion: Final sensitivity of percutaneous biopsy for establishing the diagnosis was 90%. CT features typical of pancreatic adenocarcinoma had high specificity and PPV. On some occasions, especially in frail patients with co-morbidity, it might be reasonable to assume a diagnosis of pancreatic cancer if CT features are typical, and biopsy only if CT shows atypical features.

  5. Comparative analysis of diagnostic accuracy of different brain biopsy procedures.

    Science.gov (United States)

    Jain, Deepali; Sharma, Mehar Chand; Sarkar, Chitra; Gupta, Deepak; Singh, Manmohan; Mahapatra, A K

    2006-12-01

    Image-guided procedures such as computed tomography (CT) guided, neuronavigator-guided and ultrasound-guided methods can assist neurosurgeons in localizing the intraparenchymal lesion of the brain. However, despite improvements in the imaging techniques, an accurate diagnosis of intrinsic lesion requires tissue sampling and histological verification. The present study was carried out to examine the reliability of the diagnoses made on tumor sample obtained via different stereotactic and ultrasound-guided brain biopsy procedures. A retrospective analysis was conducted of all brain biopsies (frame-based and frameless stereotactic and ultrasound-guided) performed in a single tertiary care neurosciences center between 1995 and 2005. The overall diagnostic accuracy achieved on histopathology and correlation with type of biopsy technique was evaluated. A total of 130 cases were included, which consisted of 82 males and 48 females. Age ranged from 4 to 75 years (mean age 39.5 years). Twenty per cent (27 patients) were in the pediatric age group, while 12% (16 patients) were >or= 60-years of age. A definitive histological diagnosis was established in 109 cases (diagnostic yield 80.2%), which encompassed 101 neoplastic and eight nonneoplastic lesions. Frame-based, frameless stereotactic and ultrasound-guided biopsies were done in 95, 15 and 20 patients respectively. Although the numbers of cases were small there was trend for better yield with frameless image-guided stereotactic biopsy and maximum diagnostic yield was obtained i.e, 87% (13/15) in comparison to conventional frame-based CT-guided stereotactic biopsy and ultrasound-guided biopsy. Overall, a trend of higher diagnostic yield was seen in cases with frameless image-guided stereotactic biopsy. Thus, this small series confirms that frameless neuronavigator-guided stereotactic procedures represent the lesion sufficiently in order to make histopathologic diagnosis.

  6. Nontraumatic Exertional Rhabdomyolysis Leading to Acute Kidney Injury in a Sickle Trait Positive Individual on Renal Biopsy

    Directory of Open Access Journals (Sweden)

    Kalyana C. Janga

    2018-01-01

    Full Text Available A 26-year-old African American male with a history of congenital cerebral palsy, sickle cell trait, and intellectual disability presented with abdominal pain that started four hours prior to the hospital visit. The patient denied fever, chills, diarrhea, or any localized trauma. The patient was at a party at his community center last evening and danced for 2 hours, physically exerting himself more than usual. Labs revealed blood urea nitrogen (BUN level of 41 mg/dL and creatinine (Cr of 2.8 mg/dL which later increased to 4.2 mg/dL while still in the emergency room. Urinalysis revealed hematuria with RBC > 50 on high power field. Imaging of the abdomen revealed no acute findings for abdominal pain. With fractional excretion of sodium (FeNa > 3%, findings suggested nonoliguric acute tubular necrosis. Over the next couple of days, symptoms of dyspepsia resolved; however, BUN/Cr continued to rise to a maximum of 122/14 mg/dL. With these findings, along with stable electrolytes, urine output matching the intake, and prior use of proton pump inhibitors, medical decision was altered for the possibility of acute interstitial nephritis. Steroids were subsequently started and biopsy was taken. Biopsy revealed heavy deposits of myoglobin. Creatinine phosphokinase (CPK levels drawn ten days later after the admission were found to be elevated at 334 U/dl, presuming the levels would have been much higher during admission. This favored a diagnosis of acute kidney injury (AKI secondary to exertional rhabdomyolysis. We here describe a case of nontraumatic exertional rhabdomyolysis in a sickle cell trait (SCT individual that was missed due to findings of microscopic hematuria masking underlying myoglobinuria and fractional excretion of sodium > 3%. As opposed to other causes of ATN, rhabdomyolysis often causes FeNa < 1%. The elevated fractional excretion of sodium in this patient was possibly due to the underlying inability of SCT positive individuals

  7. Biopsy transcriptome expression profiling to identify kidney transplants at risk of chronic injury: a multicentre, prospective study

    Science.gov (United States)

    O’Connell, Philip J; Zhang, Weijia; Menon, Madhav C; Yi, Zhengzi; Schröppel, Bernd; Gallon, Lorenzo; Luan, Yi; Rosales, Ivy A; Ge, Yongchao; Losic, Bojan; Xi, Caixia; Woytovich, Christopher; Keung, Karen L; Wei, Chengguo; Greene, Ilana; Overbey, Jessica; Bagiella, Emilia; Najafian, Nader; Samaniego, Milagros; Djamali, Arjang; Alexander, Stephen I; Nankivell, Brian J; Chapman, Jeremy R; Smith, Rex Neal; Colvin, Robert; Murphy, Barbara

    2016-01-01

    Summary Background Chronic injury in kidney transplants remains a major cause of allograft loss. The aim of this study was to identify a gene set capable of predicting renal allografts at risk of progressive injury due to fibrosis. Methods This Genomics of Chronic Allograft Rejection (GoCAR) study is a prospective, multicentre study. We prospectively collected biopsies from renal allograft recipients (n=204) with stable renal function 3 months after transplantation. We used microarray analysis to investigate gene expression in 159 of these tissue samples. We aimed to identify genes that correlated with the Chronic Allograft Damage Index (CADI) score at 12 months, but not fibrosis at the time of the biopsy. We applied a penalised regression model in combination with permutation-based approach to derive an optimal gene set to predict allograft fibrosis. The GoCAR study is registered with ClinicalTrials.gov, number NCT00611702. Findings We identified a set of 13 genes that was independently predictive for the development of fibrosis at 1 year (ie, CADI-12 ≥2). The gene set had high predictive capacity (area under the curve [AUC] 0·967), which was superior to that of baseline clinical variables (AUC 0·706) and clinical and pathological variables (AUC 0·806). Furthermore routine pathological variables were unable to identify which histologically normal allografts would progress to fibrosis (AUC 0·754), whereas the predictive gene set accurately discriminated between transplants at high and low risk of progression (AUC 0·916). The 13 genes also accurately predicted early allograft loss (AUC 0·842 at 2 years and 0·844 at 3 years). We validated the predictive value of this gene set in an independent cohort from the GoCAR study (n=45, AUC 0·866) and two independent, publically available expression datasets (n=282, AUC 0·831 and n=24, AUC 0·972). Interpretation Our results suggest that this set of 13 genes could be used to identify kidney transplant recipients at

  8. A Longitudinal Comparison of Arm Morbidity in Stage I-II Breast Cancer Patients Treated with Sentinel Lymph Node Biopsy, Sentinel Lymph Node Biopsy Followed by Completion Lymph Node Dissection, or Axillary Lymph Node Dissection

    NARCIS (Netherlands)

    Kootstra, Jan J.; Hoekstra-Weebers, Josette E. H. M.; Rietman, Johan S.; de Vries, Jakob; Baas, Peter C.; Geertzen, Jan H. B.; Hoekstra, Harald J.

    Background. Long-term shoulder and arm function following sentinel lymph node biopsy (SLNB) may surpass that following complete axillary lymph node dissection (CLND) or axillary lymph node dissection (ALND). We objectively examined the morbidity and compared outcomes after SLNB, SLNB + CLND, and

  9. A longitudinal comparison of arm morbidity in stage I-II breast cancer patients treated with sentinel lymph node biopsy, sentinel lymph node biopsy followed by completion lymph node dissection, or axillary lymph node dissection

    NARCIS (Netherlands)

    Kootstra, Jan J.; Hoekstra-Weebers, Josette E.; Rietman, Johan Swanik; de Vries, Jakob; Baas, Peter C.; Geertzen, Jan H.B.; Hoekstra, Harald J.

    2010-01-01

    Background: Long-term shoulder and arm function following sentinel lymph node biopsy (SLNB) may surpass that following complete axillary lymph node dissection (CLND) or axillary lymph node dissection (ALND). We objectively examined the morbidity and compared outcomes after SLNB, SLNB + CLND, and

  10. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  11. Effects of muscular biopsy on the mechanics of running.

    Science.gov (United States)

    Morin, Jean-Benoit; Samozino, Pierre; Féasson, Léonard; Geyssant, André; Millet, Guillaume

    2009-01-01

    Muscle biopsy is a widely used technique in protocols aiming at studying physical capacities and fiber profiles of athletes, and muscular adaptations to exercise. Side effects of biopsy alone on physiological parameters have recently been pointed out, and we sought to determine whether a single biopsy had effects on the main stride mechanical parameters. Ten male runners performed 4-min runs before and after undergoing a biopsy of their left vastus lateralis muscle. Step frequency and duty factor were significantly higher after biopsy (2.86 +/- 0.14 vs. 2.82 +/- 0.15 Hz, and 0.77 +/- 0.04 vs. 0.75 +/- 0.05, respectively), whereas other factors were significantly lower: maximal vertical ground reaction force (1,601 +/- 240 vs. 1,643 +/- 230 N), loading rate (53.9 +/- 12.8 vs. 58.4 +/- 13.5 bw s(-1)), center of mass vertical displacement (0.056 +/- 0.008 vs. 0.058 +/- 0.008 m) and external mechanical work at each step (1.14 +/- 0.10 vs. 1.24 +/- 0.10 J kg(-1) step(-1)). These effects were observed on the left (biopsed) leg, but also on the right one for the external mechanical work, the duty factor and the maximal vertical ground reaction force, showing that a single biopsy had both ipsi- and contralateral effects on running mechanics.

  12. Clinical significance of inadequate endometrial biopsies prior to hysterectomy.

    Science.gov (United States)

    Turney, Emily H; Farghaly, Hanan; Eskew, Ashley M; Parker, Lynn P; Milam, Michael R

    2012-01-01

    To evaluate preoperative clinical risk factors associated with significant uterine histopathologic abnormalities in final hysterectomy specimens in patients with inadequate preoperative endometrial biopsies. This is an institutional review board-approved, retrospective cohort analysis of 469 consecutive patients who underwent preoperative endometrial biopsies with subsequent hysterectomy from January 1, 2005, to December 31, 2009, at the University of Louisville Medical Center. We analyzed risk factors for inadequate biopsy and for final diagnosis of endometrial pathology (defined as endometrial hyperplasia or uterine cancer). Of the 469 preoperative endometrial biopsies reviewed, 26.2% (123/469) were inadequate (IBx) and 73.8% (346/469) were adequate and benign. IBx on endometrial biopsies was associated with a greater risk of having significant uterine histopathologic abnormalities on final hysterectomy specimens (6.5% vs. 2.3%, RR 2.8 [95% CI 1.1-7.3], p = 0.04). Although inadequate endometrial biopsies are a common finding, they can be associated with significant uterine histopathologic abnormalities on final hysterectomy specimens.

  13. Applications of stable isotopes

    International Nuclear Information System (INIS)

    Gregg, C.T.

    1977-01-01

    Clinical applications include the galactose breath test which consists of oral administration of 13 C-labeled galactose and measurement of the 13 C content of respired CO 2 as a function of time in patients with cirrhotic livers for diagnosis of liver dysfunction. Another application was the breath test to study glucose metabolism in children. Respired 13 CO 2 from ingested glucose- 13 C was measured for normal and diabetic children. Studies on mice in which 60 percent of the body carbon was replaced with 13 C failed to show significant effects of the isotope. Studies on biochemical applications include nuclear magnetic resonance studies of 13 C-labeled amino acids from Chlorella pyrenoidosa; studies on 15 N nmr spectra of arginine-guanidino- 13 C-2,3-- 15 N 2 as a function of pH; and isolation of fatty acids from algae

  14. A New DOA Algorithm Based on Nonlinear Compress Core Function in Symmetric α-stable Distribution Noise Environment%一种对称琢稳定分布噪声环境下DOA估计新算法

    Institute of Scientific and Technical Information of China (English)

    马金全; 葛临东; 童莉

    2014-01-01

    脉冲噪声环境下波达方向( DOA)估计是阵列信号处理领域一个新兴研究方向。针对α稳定分布噪声环境下经典MUSIC算法性能退化的问题,提出了一种新的基于非线性压缩核函数( NCCF)的DOA估计算法。该算法利用基于NCCF的有界矩阵代替了MUSIC的协方差矩阵,通过对有界矩阵进行特征分解确定信号子空间和噪声子空间,借用MUSIC谱估计公式进行谱峰搜索,得到DOA的估计值。仿真结果表明,NCCF-MUSIC算法运算复杂度较低,相比于基于分数低阶统计量( FLOS)的MUSIC方法和基于广义类相关熵( GCAS)的MUSIC算法,该方法具有更好的准确度和稳定性。%Direction of arrival ( DOA) estimation in the impulse noise environment is a new research direc-tion in the array signal processing field. To solve the problem of performance degradation when applying classic MUSIC algorithm for DOA estimation in the α-stable distribution noise environment,a novel DOA estimation algorithm based on a nonlinear compress core function ( NCCF ) is provided and named as the NCCF-MUSIC. To obtain a DOA estimation,the NCCF-MUSIC method replaces the covariance matrix in MUSIC by a bounded matrix based on the NCCF,and then determines the signal subspace and the noise subspace by feature decomposition, and finally, introduces the MUSIC spectrum estimation algorithm to make a spectral peak searching. Simulation results show that the new NCCF-MUSIC method with a lower computation cost has the higher performance in accuracy and validity than the MUSIC methods based on fractional lower order statistics ( FLOS) or based on generalized correntropy-analogous statistics ( GCAS) .

  15. Characterization of adrenal masses: can image replace biopsy?; Charakterisierung von Nebennierenraumforderungen. Kann die Bildgebung die Biopsie ersetzen?

    Energy Technology Data Exchange (ETDEWEB)

    Heinz-Peer, G.; Hoenigschnabel, S.; Lechner, G. [Universtaetsklinik fuer Radiodiagnostik, Abt. Chirurgische Faecher, Wien (Austria)]|[Ludwig Boltzmann-Inst. fuer Radiologische Tumorforschung, Wien (Austria); Niederle, B. [Universitaetsklinik fuer Chirurgie, Univ. Wien (Austria)

    1999-07-01

    This paper describes the diagnostic value of new imaging techniques in characterization of adrenal masses and evaluates the role of adrenal biopsy. For differentiation of benign and malignant adrenal lesions, sensitivities and specificities of 85-100% can be reached by unenhanced computed tomography (CT) methods, chemical shift techniques in magnetic resonance imaging (MRI), delayed enhanced CT techniques, and by evaluation of wash-out curves in contrast-enhanced CT. The diagnostic value of all CT techniques depends on threshold values. The value of dynamic contrast-enhanced MRI is under discussion and should be reevaluated by using delayed enhance series. Biochemical and scintigraphic methods (NP 59 iodine iodomethyl-norcholesterol and MIBG meta-iodobenzylguanidine scintigrams) are valuable for the diagnosis of functional adrenal masses; however, they do not allow differentiation of benign and malignant tumors. According to excellent results of new imaging techniques in characterization of adrenal masses, the indications for fine-needle aspiration biopsy have already regressed, as have complications associated with this invasive technique. (orig.) [Deutsch] Diese Arbeit beschreibt die Moeglichkeiten der Charakterisierung von Nebennierenlaesionen durch die Bildgebung von neuen Untersuchungstechniken und evaluiert den geaenderten Stellenwert der Nebennierenbiopsie. Mittels der nativen Computertomographie (CT), der Chemical-Shift-Technik der Magnetresonanztomographie (MRT) oder Dichtemessungen in CT-Kontrastmittelspaetserien bzw. der Bestimmung des prozentuellen Dichteverlustes in CT-Kontrastmittelserien koennen in der Differenzierung von benignen und malignen Nebennierenlaesionen Sensitivitaeten und Spezifitaeten von 85%-100% erreicht werden. Die diagnostische Wertigkeit der CT-Techniken ist abhaengig von der Definition eines Schwellenwertes. Die Wertigkeit der dynamischen KM-verstaerkten MRT wird derzeit unterschiedlich beurteilt und sollte anhand verbesserter

  16. Stereological quantification of immune-competent cells in baseline biopsy specimens from achilles tendons

    DEFF Research Database (Denmark)

    Kragsnaes, Maja Skov; Fredberg, Ulrich; Stribolt, Katrine

    2014-01-01

    BACKGROUND: Limited data exist on the presence and function of immune-competent cells in chronic tendinopathic tendons and their potential role in inflammation and tissue healing as well as in predicting long-term outcome. PURPOSE: To quantify subtypes of immune-competent cells in biopsy specimens...... immunohistochemically by quantifying the presence of macrophages (CD68-PGM1(+), CD68-KP1(+)), hemosiderophages (Perls blue), T lymphocytes (CD2(+), CD3(+), CD4(+), CD7(+), CD8(+)), B lymphocytes (CD20(+)), natural killer cells (CD56(+)), mast cells (NaSDCl(+)), Schwann cells (S100(+)), and endothelial cells (CD34......(+)) using a stereological technique. A follow-up examination was conducted more than 4 years (range, 4-9 years) after the biopsy procedure to evaluate the long-term presence of Achilles tendon symptoms. RESULTS: Macrophages, T lymphocytes, mast cells, and natural killer cells were observed in the majority...

  17. Testicular biopsy in psittacine birds (Psittaciformes): impact of endoscopy and biopsy on health, testicular morphology, and sperm parameters.

    Science.gov (United States)

    Hänse, Maria; Krautwald-Junghanns, Maria-Elisabeth; Reitemeier, Susanne; Einspanier, Almuth; Schmidt, Volker

    2013-12-01

    Histologic examination of a testicular biopsy sample may be required to evaluate the reproductive status of male psittacine birds. The purpose of this study was to evaluate the viability of testicular sampling from live birds by assessing the impact on the birds' health, testicular integrity, and sperm quality. Testicular biopsy samples were obtained by endoscopy 4 times during 12 months from 9 cockatiels (Nymphicus hollandicus) and 7 rose-ringed parakeets (Psittacula krameri). Only 2 of 16 birds showed testicular cicatrization or divided testicular tissue after a single endoscopy. Further complications, such as damage to the air sacs or bleeding, predominantly occurred in subsequent endoscopies. In both species, endoscopy and testicular biopsy caused only minor or transient effects on sperm production and sperm quality. These results support that a single testicular biopsy is a viable method for evaluating the reproductive status of male psittacine birds.

  18. Magnetic Resonance and Ultrasound Image Fusion Supported Transperineal Prostate Biopsy Using the Ginsburg Protocol: Technique, Learning Points, and Biopsy Results.

    Science.gov (United States)

    Hansen, Nienke; Patruno, Giulio; Wadhwa, Karan; Gaziev, Gabriele; Miano, Roberto; Barrett, Tristan; Gnanapragasam, Vincent; Doble, Andrew; Warren, Anne; Bratt, Ola; Kastner, Christof

    2016-08-01

    Prostate biopsy supported by transperineal image fusion has recently been developed as a new method to the improve accuracy of prostate cancer detection. To describe the Ginsburg protocol for transperineal prostate biopsy supported by multiparametric magnetic resonance imaging (mpMRI) and transrectal ultrasound (TRUS) image fusion, provide learning points for its application, and report biopsy results. The article is supplemented by a Surgery in Motion video. This single-centre retrospective outcome study included 534 patients from March 2012 to October 2015. A total of 107 had no previous prostate biopsy, 295 had benign TRUS-guided biopsies, and 159 were on active surveillance for low-risk cancer. A Likert scale reported mpMRI for suspicion of cancer from 1 (no suspicion) to 5 (cancer highly likely). Transperineal biopsies were obtained under general anaesthesia using BiopSee fusion software (Medcom, Darmstadt, Germany). All patients had systematic biopsies, two cores from each of 12 anatomic sectors. Likert 3-5 lesions were targeted with a further two cores per lesion. Any cancer and Gleason score 7-10 cancer on biopsy were noted. Descriptive statistics and positive predictive values (PPVs) and negative predictive values (NPVs) were calculated. The detection rate of Gleason score 7-10 cancer was similar across clinical groups. Likert scale 3-5 MRI lesions were reported in 378 (71%) of the patients. Cancer was detected in 249 (66%) and Gleason score 7-10 cancer was noted in 157 (42%) of these patients. PPV for detecting 7-10 cancer was 0.15 for Likert score 3, 0.43 for score 4, and 0.63 for score 5. NPV of Likert 1-2 findings was 0.87 for Gleason score 7-10 and 0.97 for Gleason score ≥4+3=7 cancer. Limitations include lack of data on complications. Transperineal prostate biopsy supported by MRI/TRUS image fusion using the Ginsburg protocol yielded high detection rates of Gleason score 7-10 cancer. Because the NPV for excluding Gleason score 7-10 cancer was very

  19. CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

    International Nuclear Information System (INIS)

    Schaefer, Philipp J.; Fabel, Michael; Bolte, Hendrik; Schaefer, Fritz K. W.; Jahnke, Thomas; Heller, Martin; Lammer, Johannes; Biederer, Juergen

    2010-01-01

    The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helically bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 ± 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 ± 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 ± 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 ± 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 ± 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.

  20. A randomized controlled trial of electrocoagulation-enabled biopsy versus conventional biopsy in the diagnosis of endobronchial lesions.

    Science.gov (United States)

    Khan, Ajmal; Aggarwal, Ashutosh N; Agarwal, Ritesh; Bal, Amanjit; Gupta, Dheeraj

    2011-01-01

    Although electrocoagulation at time of endobronchial biopsy can potentially reduce procedure-related bleeding during fiberoptic bronchoscopy (FOB), it can also impair quality of tissue specimen; credible data for either are lacking. To evaluate the impact of hot biopsy on the quality of tissue samples and to quantify the amount of procedure-related bleeding during endobronchial biopsy. In this single-center, prospective, single-blind, randomized controlled study we included adult patients referred for FOB and having endobronchial lesions. Patients were randomized to bronchial biopsy using an electrocoagulation-enabled biopsy forceps, with (EC+ group) or without (EC- group) application of electrocoagulation current (40 W for 10 s in a monopolar mode). Procedure-related bleeding was semi-quantified by observer description, as well as through a visual analogue scale. Overall quality of biopsy specimen and tissue damage were assessed and graded by a pulmonary pathologist blinded to FOB details. 160 patients were randomized to endobronchial biopsy with (n = 81) or without (n = 79) the application of electrocoagulation. There were no severe bleeding episodes in either group, and severity of bleeding in the EC+ and EC- groups was similar (median visual analogue scale scores of 14 and 16, respectively). Histopathological diagnosis was similar in the EC+ and EC- groups (77.8% and 82.3%, respectively). There was no significant difference in tissue quality between the two groups. Use of electrocoagulation-enabled endobronchial biopsy does not alter specimen quality and does not result in any significant reduction in procedure-related bleeding. Copyright © 2010 S. Karger AG, Basel.

  1. Magnetic resonance imaging-guided biopsies may improve diagnosis in biopsy-naive men with suspicion of prostate cancer

    DEFF Research Database (Denmark)

    Winther, Mads Dochedahl; Balslev, Ingegerd; Boesen, Lars

    2017-01-01

    INTRODUCTION: The purpose of this pilot study was to investigate whether a short prostate biparametric magnetic resonance imaging (bp-MRI) protocol provides a valuable diagnostic addition for biopsy guidance in biopsy-naive men with a suspicion of prostate cancer (PCa). METHODS: A total of 62...... biopsy-naive patients referred to a systematic transrectal ultrasound biopsy (TRUS-bx) due to suspicion of PCa were prospectively enrolled. Bp-MRI was performed before biopsy. All lesions were scored according to the modified Prostate Imaging Reporting and Data System (PI-RADS) version 2. All patients...... underwent TRUS-bx followed by bp-MRI-guided biopsies (bp-MRI-bx) under MRI/TRUS image fusion from any bp-MRI suspicious lesions not obviously targeted by TRUS-bx. RESULTS: PCa was found in 42 (68%) and 32 (52%) patients by TRUS-bx and bp-MRI-bx, respectively. Bp-MRI-bx de-tected PCa in one patient who had...

  2. Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast

    International Nuclear Information System (INIS)

    Perlet, C.; Sittek, H.; Schneider, P.; Reiser, M.; Heinig, A.; Stets, C.; Heywang-Koebrunner, S.H.; Prat, X.; Lamarque, J.; Taourel, P.; Casselman, J.; Baath, L.; Anderson, I.

    2002-01-01

    The purpose of this multicenter study was to determine the accuracy and clinical value of a dedicated breast biopsy system which allows for MR-guided vacuum biopsy (VB) of contrast-enhancing lesions. In five European centers, MR-guided 11-gauge VB was performed on 341 lesions. In 7 cases VB was unsuccessful. This was immediately realized on postinterventional images or direct follow-up combined with histopathology-imaging correlation; thus, a false-negative diagnosis was avoided. Histology of 334 successful biopsies yielded 84 (25%) malignancies, 17 (5%) atypical ductal hyperplasias, and 233 (70%) benign entities. Verification of malignant or borderline lesions included reexcision of the biopsy cavity. Benign histologic biopsy results were verified by retrospective correlation with the pre- and postinterventional MRI and by subsequent follow-up. Our results indicate that MR-guided VB, in combination with the dedicated biopsy coil, offers the possibility to accurately diagnose even very small lesions that can only be visualized or localized by MRI. (orig.)

  3. Stable isotope methodology and its application to nutrition and gastroenterology

    International Nuclear Information System (INIS)

    Klein, P.D.; Hachey, D.L.; Wong, W.W.; Abrams, S.A.

    1993-01-01

    This report describes the activities of the Stable Isotope Laboratory in its function as a core resource facility for stable isotope applications in human nutrition research. Three aspects are covered: Training of visitors, assessment of new instrumentation, and development of new methodology. The research achievements of the laboratory are indicated in the publications that appeared during this period. (author). 23 refs

  4. Trophic position of coexisting krill species: a stable isotope approach

    DEFF Research Database (Denmark)

    Agersted, Mette Dalgaard; Bode, Antonio; Nielsen, Torkel Gissel

    2014-01-01

    Four krill species with overlapping functional biology coexist in Greenland waters. Here, we used stable isotopes to investigate and discuss their trophic role and mode of coexistence. Bulk carbon (δ13C) and nitrogen (δ15N) stable isotope analyses of Thysanoessa longicaudata, T. inermis, T. raschii...

  5. MRI-Targeted or Standard Biopsy for Prostate-Cancer Diagnosis.

    Science.gov (United States)

    Kasivisvanathan, Veeru; Rannikko, Antti S; Borghi, Marcelo; Panebianco, Valeria; Mynderse, Lance A; Vaarala, Markku H; Briganti, Alberto; Budäus, Lars; Hellawell, Giles; Hindley, Richard G; Roobol, Monique J; Eggener, Scott; Ghei, Maneesh; Villers, Arnauld; Bladou, Franck; Villeirs, Geert M; Virdi, Jaspal; Boxler, Silvan; Robert, Grégoire; Singh, Paras B; Venderink, Wulphert; Hadaschik, Boris A; Ruffion, Alain; Hu, Jim C; Margolis, Daniel; Crouzet, Sébastien; Klotz, Laurence; Taneja, Samir S; Pinto, Peter; Gill, Inderbir; Allen, Clare; Giganti, Francesco; Freeman, Alex; Morris, Stephen; Punwani, Shonit; Williams, Norman R; Brew-Graves, Chris; Deeks, Jonathan; Takwoingi, Yemisi; Emberton, Mark; Moore, Caroline M

    2018-05-10

    Multiparametric magnetic resonance imaging (MRI), with or without targeted biopsy, is an alternative to standard transrectal ultrasonography-guided biopsy for prostate-cancer detection in men with a raised prostate-specific antigen level who have not undergone biopsy. However, comparative evidence is limited. In a multicenter, randomized, noninferiority trial, we assigned men with a clinical suspicion of prostate cancer who had not undergone biopsy previously to undergo MRI, with or without targeted biopsy, or standard transrectal ultrasonography-guided biopsy. Men in the MRI-targeted biopsy group underwent a targeted biopsy (without standard biopsy cores) if the MRI was suggestive of prostate cancer; men whose MRI results were not suggestive of prostate cancer were not offered biopsy. Standard biopsy was a 10-to-12-core, transrectal ultrasonography-guided biopsy. The primary outcome was the proportion of men who received a diagnosis of clinically significant cancer. Secondary outcomes included the proportion of men who received a diagnosis of clinically insignificant cancer. A total of 500 men underwent randomization. In the MRI-targeted biopsy group, 71 of 252 men (28%) had MRI results that were not suggestive of prostate cancer, so they did not undergo biopsy. Clinically significant cancer was detected in 95 men (38%) in the MRI-targeted biopsy group, as compared with 64 of 248 (26%) in the standard-biopsy group (adjusted difference, 12 percentage points; 95% confidence interval [CI], 4 to 20; P=0.005). MRI, with or without targeted biopsy, was noninferior to standard biopsy, and the 95% confidence interval indicated the superiority of this strategy over standard biopsy. Fewer men in the MRI-targeted biopsy group than in the standard-biopsy group received a diagnosis of clinically insignificant cancer (adjusted difference, -13 percentage points; 95% CI, -19 to -7; Pprostate cancer who had not undergone biopsy previously. (Funded by the National Institute for

  6. Sonographically guided core biopsy of the breast: comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods

    International Nuclear Information System (INIS)

    Cho, Nariya; Moon, Woo Kyung; Cha, Joo Hee

    2005-01-01

    To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies of breast lesions. We retrospectively reviewed all sonographically guided core biopsies performed from January 2002 to February 2004. The sonographically guided core biopsies were performed with using a 14-gauge automated gun on 562 breast lesions or with using an 11-gauge vacuum-assisted device on 417 lesions. The histologic findings were compared with the surgical, imaging and follow-up findings. The histologic underestimation rate, the repeat biopsy rate and the false negative rates were compared between the two groups. A repeat biopsy was performed on 49 benign lesions because of the core biopsy results of the high-risk lesions (n=24), the imaging-histologic discordance (n=5), and the imaging findings showing disease progression (n=20). The total underestimation rates, according to the biopsy device, were 55% (12/22) for the 14-gauge automated gun biopsies and 36% (8/22) for the 11-gauge vacuum-assisted device (ρ = 0.226). The atypical ductal hyperplasia (ADH) underestimation (i.e., atypical ductal hyperplasia at core biopsy and carcinoma at surgery) was 58% (7/12) for the 14-gauge automated gun biopsies and 20% (1/5) for the 11-gauge vacuum-assisted biopsies. The ductal carcinoma in situ (DCIS) underestimation rate (i.e., ductal carcinoma in situ upon core biopsy and invasive carcinoma found at surgery) was 50% (5/10) for the 14-gauge automated gun biopsies and 41% (7/17) for the 11-gauge vacuum-assisted biopsies. The repeat biopsy rates were 6% (33/562) for the 14-gauge automated gun biopsies and 3.5% (16/417) for the 11-gauge vacuum-assisted biopsies. Only 5 (0.5%) of the 979 core biopsies were believed to have missed the malignant lesions. The false-negative rate was 3% (4 of 128 cancers) for the 14-gauge automated gun biopsies and 1% (1 of 69 cancers) for the 11-gauge vacuum-assisted biopsies. The outcomes of the

  7. Evaluation of autofocus measures for microscopy images of biopsy and cytology

    Science.gov (United States)

    Redondo, R.; Bueno, M. G.; Valdiviezo, J. C.; Nava, R.; Cristóbal, G.; García, M.; Déniz, O.; Escalante-Ramírez, B.

    2011-08-01

    An essential and indispensable component of automated microscopy is the automatic focusing system, which determines the in-focus position of a given field of view by searching for the maximal of an autofocus function over a range of z-axis positions. The autofocus function and its computation time are crucial to the accuracy and efficiency of the system. In this paper, we analyze and evaluate fifteen autofocus algorithms for biopsy and cytology microscopy images, ranging from the already well known methods to those proposed recently. Results have shown that there is a trade-off between computational cost and accuracy. Finally, the error committed by each of the algorithms is presented.

  8. Stable isotope research pool inventory

    International Nuclear Information System (INIS)

    1980-12-01

    This report contains a listing of electromagnetically separated stable isotopes which are available for distribution within the United States for non-destructive research use from the Oak Ridge National Laboratory on a loan basis. This inventory includes all samples of stable isotopes in the Materials Research Collection and does not designate whether a sample is out on loan or in reprocessing

  9. Percutaneous ultrasound-guided renal biopsy: A Libyan experience

    Science.gov (United States)

    Mishra, A.; Tarsin, R.; ElHabbash, B.; Zagan, N.; Markus, R.; Drebeka, S.; AbdElmola, K.; Shawish, T.; Shebani, A.; AbdElmola, T.; ElUsta, A.; Ehtuish, E. F.

    2010-01-01

    This study was done to assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy (PRB), to ascertain the risk factors for complications and determine the optimal period of observation. The radiologist (A.M.) at the National Organ Transplant Centre, Central Hospital, Tripoli, Libya, performed 86 PRBs between February 1, 2006, and January 31, 2008, using an automated biopsy gun with 16-gauge needle. Coagulation profile was done in all the patients. All patients were kept on strict bed rest for six hours post-procedure. Eighty six renal biopsies were performed on 78 patients referred from rheumatology department and eight post-kidney transplant recipients; 23 were males with age range 15 – 56 years and 63 females with age range 16 – 66 years. A mean of 17.5 glomeruli were present in each specimen. A glomerular yield of less than five glomeruli was seen in four biopsies. Class I lupus nephritis (LN) was seen in 1 patient, class II lupus nephritis in 7 patients, class III LN in 13 patients and class IV LN in 29 patients. All the eight renal allografts were diagnosed as acute tubular necrosis or acute interstitial rejection. The risk of post-biopsy bleeding was higher in women, older patients and higher PTT. The overall complication rate was 5.8%. Three complications were observed within six hours of biopsy. No late complication was seen. PRB under real-time ultrasound-guidance is a safe and efficacious procedure to establish the histological diagnosis and should be done as out-patient procedure. Observation time of six hours post-biopsy is optimal. PMID:20835320

  10. Epidemiology of biopsy-proven glomerulonephritis in Queensland adults.

    Science.gov (United States)

    Jegatheesan, Dev; Nath, Karthik; Reyaldeen, Reza; Sivasuthan, Goutham; John, George T; Francis, Leo; Rajmokan, Mohana; Ranganathan, Dwarakanathan

    2016-01-01

    There is a paucity of data pertaining to the incidence of biopsy-proven glomerulonephritis (GN) in Australia. This retrospective study aims to review the data from all adult native renal biopsies performed in the state of Queensland from 2002 to 2011--comparing results with centres from across the world. Pathology reports of 3697 adult native kidney biopsies were reviewed, of which 2048 had GN diagnoses. Age, gender, clinical indication and histopathology findings were compared. The average age at biopsy was 48 ± 17 years. Male preponderance was noted overall (∼60%), with lupus nephritis being the only individual GN with female predilection. The average rate of biopsy was 12.04 per hundred thousand people per year (php/yr). Nephrotic and nephritic syndromes comprised approximately 75% of all clinical indications that lead to GN diagnoses. IgA nephropathy (1.41 php/yr) was the most common primary GN followed by focal segmental glomerulosclerosis (1.02 php/yr) and crescentic GN (0.73 php/yr). Diabetic nephropathy (0.84 php/yr), lupus nephritis (0.69 php/yr) and amyloidosis (0.19 php/yr) were the most commonly identified secondary GN. IgA nephropathy is the predominant primary GN in Queensland, and nephrotic syndrome the most common indication for a renal biopsy. While crescentic GN incidence has significantly increased with time, focal segmental glomerulosclerosis incidence has not shown any trend. Incidence of GN overall appears to increase with age. The annual rate of biopsy in this study appears lower than previously published in an Australian population. © 2015 Asian Pacific Society of Nephrology.

  11. MR-guided breast biopsy and hook wire marking using a low-field (0.23 T) scanner with optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Reinikainen, Heli; Blanco Sequeiros, Andreas M.; Ojala, Risto; Paeaekkoe, Eija; Tervonen, Osmo; Vaara, Teuvo

    2007-01-01

    The purpose of this study was to evaluate the technical feasibility of MR-guided percutaneous breast biopsy (LCNB) and breast hook wire marking in a low-field (0.23 T) MRI system with optical instrument tracking. MR-guided core biopsy and/or hook wire marking was performed on 13 lesions observable at MR imaging only. Seven breast LCNBs and 10 hook wire markings were performed under MR guidance on 11 patients. The diagnosis was confirmed by excision biopsy or mastectomy in 12 lesions and with histopathological and cytological diagnosis and 12-month clinical follow-up in one lesion. All lesions seen in the high-field scanner were also successfully identified and targeted in the low-field scanner. The following procedures were typically technically successful. There were difficulties due to unsatisfactory functioning of some core biopsy guns. Detailed description of low-field MR guidance and optical tracking in breast biopsies is provided. The procedure seems accurate and safe and provides means to obtain a histological diagnosis of a breast lesion only seen with MRI. The low-field biopsy system is comparable to the high-field MRI system. MR-compatible biopsy guns need to be improved. (orig.)

  12. Fibroadenoma: can fine needle aspiration biopsy avoid short term follow-up?

    Science.gov (United States)

    Leconte, I; Abraham, C; Galant, C; Sy, M; Berlière, M; Fellah, L

    2012-10-01

    To confirm whether fine needle aspiration biopsy (FNAB) can avoid close monitoring, a source of worry for women patients with a suspected fibroadenoma found by ultrasound, and requiring their compliance. Over 39months, 427 nodules with a diagnosis of fibroadenoma were sampled in 372 patients using ultrasound-guided FNAB. The sonographic appearance of all the nodules suggested BI-RADS category 3 fibroadenomas. The mean size of the fibroadenomas was 9mm. The mean duration of follow-up was 29.7months. Seven nodules had atypical cytology: a microbiopsy and/or excision found a simple fibroadenoma (n=3), mastitis (n=1), a fibroadenoma associated with a papilloma (n=1), fibrosis (n=1) and normal tissue (n=1). Seven other nodules were resected during treatment for synchronous cancer, and were diagnosed as fibroadenomas. Two hundred and seventy-six nodules were followed-up (121 patients were lost to follow-up [n=132]) and the appearance of 263 nodules (95.29%) was stable. Seven nodules, which had increased in size, underwent another FNAB or microbiopsy or surgery. Five nodules were not found again. The borders of one nodule showed modifications. The use of fine needle aspiration biopsy, interpreted by an experienced cytologist, means that short term follow-up of fibroadenomas can be avoided. Copyright © 2012 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  13. Learning curves for ultrasound guided lung biopsy in the hands of respiratory physicians

    DEFF Research Database (Denmark)

    Laursen, Christian; Naur, Therese Maria Henriette; Bodtger, Uffe

    2016-01-01

    are depicted in figure 1. Six of the physicians had learning curves with a relatively downward or stable projection as a sign of developing competence. Three physicians, however, had learning curves with an upward projection indicating unacceptable competence in performing the procedure......Background: The aim of this study was to determine learning curves for ultrasound guided transthoracic needle biopsies (US-TTNB) performed by respiratory physicians after implementation at three different centers.Methods: During January 2012 to August 2014 patients were included if they had...... a registered US-TTNB procedure at any of the three centers. The US-TTNB was defined as being successful if the result was diagnostic and otherwise as being unsuccessful. Histology or cytology results and clinical follow-up were used as a reference tests. The learning curves for physicians having performed...

  14. Kidney Biopsy in Jordan: Complications and Histopathological Findings

    Directory of Open Access Journals (Sweden)

    Ghnaimat Mohamad

    1999-01-01

    Full Text Available In this retrospective study, we reviewed the medical records, and histopathology findings of 191 patients who underwent renal biopsies at King Hussein Medical Center (KHMC during a four-year period (1993-97. All were performed using Tru-Cut needles under ultrasound guidance. There were 119 males (62.3% and 72 females (37.7%; the mean age was 29.1 years (range 5-76 years. Side effects of the renal biopsies included pain at the site of he biopsy in 17 (8.9%, gross hematuria in six (3.1% and hematuria requiring blood transfusion in one (0.5% patient. Nephrotic syndrome was the most common indication for biopsy followed by acute renal failure of unknown etiology. Among the nephritic patients, minimal change disease and post-infectious glomerulonephritis (GN were the commonest findings in children below the age of 15 years, membrano-proliferative GN ranked first in adults whole membranous GN and amyloidosis were more common in the elderly. WE conclude that renal biopsy was associated with a n acceptably low rate of complications in our practice, and that the patterns of renal histology vary slightly from those reported from other countries.

  15. Remote biopsy darting and marking of polar bears

    Science.gov (United States)

    Pagano, Anthony M.; Peacock, Elizabeth; McKinney, Melissa A.

    2014-01-01

    Remote biopsy darting of polar bears (Ursus maritimus) is less invasive and time intensive than physical capture and is therefore useful when capture is challenging or unsafe. We worked with two manufacturers to develop a combination biopsy and marking dart for use on polar bears. We had an 80% success rate of collecting a tissue sample with a single biopsy dart and collected tissue samples from 143 polar bears on land, in water, and on sea ice. Dye marks ensured that 96% of the bears were not resampled during the same sampling period, and we recovered 96% of the darts fired. Biopsy heads with 5 mm diameters collected an average of 0.12 g of fur, tissue, and subcutaneous adipose tissue, while biopsy heads with 7 mm diameters collected an average of 0.32 g. Tissue samples were 99.3% successful (142 of 143 samples) in providing a genetic and sex identification of individuals. We had a 64% success rate collecting adipose tissue and we successfully examined fatty acid signatures in all adipose samples. Adipose lipid content values were lower compared to values from immobilized or harvested polar bears, indicating that our method was not suitable for quantifying adipose lipid content.

  16. Current status of core needle biopsy of the thyroid

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Jung Hwan [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Thyroid nodules are a common clinical problem. Fine-needle aspiration (FNA) and large-needle biopsy have been used to diagnose thyroid nodules. Before the 1980s, large-needle biopsy was the standard procedure for the thyroid, but FNA became the standard diagnostic tool in the 1980s because it is a safe procedure that leads to accurate diagnoses. With advances in core needle biopsy (CNB) devices (i.e., spring-activated core needles) and development of high-resolution ultrasound, it has become possible to make accurate diagnoses while minimizing complications. Although 18- to 21-gauge core needles can be used to biopsy thyroid nodules, 18-gauge needles are most commonly used in Korea. The relationships among the size of the needle, the number of core specimens, and diagnostic accuracy have not yet been conclusively established, but the general tendency is that thinner needles cause less damage to the normal thyroid, but allow a smaller amount of thyroid tissue to be biopsied to be obtained. These relationships may be validated in the future.

  17. [Current situation and prospect of breast cancer liquid biopsy].

    Science.gov (United States)

    Zhou, B; Xin, L; Xu, L; Ye, J M; Liu, Y H

    2018-02-01

    Liquid biopsy is a diagnostic approach by analyzing body fluid samples. Peripheral blood is the most common sample. Urine, saliva, pleural effusion and ascites are also used. Now liquid biopsy is mainly used in the area of neoplasm diagnosis and treatment. Compared with traditional tissue biopsy, liquid biopsy is minimally invasive, convenient to sample and easy to repeat. Liquid biopsy mainly includes circulating tumor cells and circulating tumor DNA (ctDNA) detection. Detection of ctDNA requires sensitive and accurate methods. The progression of next-generation sequencing (NGS) and digital PCR promote the process of studies in ctDNA. In 2016, Nature published the result of whole-genome sequencing study of breast cancer. The study found 1 628 mutations of 93 protein-coding genes which may be driver mutations of breast cancer. The result of this study provided a new platform for breast cancer ctDNA studies. In recent years, there were many studies using ctDNA detection to monitor therapeutic effect and guide treatment. NGS is a promising technique in accessing genetic information and guiding targeted therapy. It must be emphasized that ctDNA detection using NGS is still at research stage. It is important to standardize ctDNA detection technique and perform prospective clinical researches. The time is not ripe for using ctDNA detection to guide large-scale breast cancer clinical practice at present.

  18. Ultrasound-guided percutaneous biopsy of digestive tract lesions

    International Nuclear Information System (INIS)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C.; Marco, S. F.; Fernandez, P.

    1999-01-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs

  19. Transthoracic needle biopsy: factors effecting risk of pneumothorax

    International Nuclear Information System (INIS)

    Topal, Ugur; Ediz, Buelent

    2003-01-01

    Objective: to evaluate the factors that could effect the risk of pneumothorax in patients undergoing transthoracic biopsy. Material and methods: variables that could increase the risk of pneumothorax were evaluated in 453 CT-guided transthoracic biopsies. Factors were evaluated in two groups: (1) lesion related (presence of emphysema around the lesion, lesion depth, cavitation, presence of fissure/atelectasis and pleural tag in the needle trajectory); and (2) procedure related (biopsy type, needle size, number of passages, level of experience of the operator). All variables were analysed by χ 2 test and multivariate logistic regression statistics. Results: pneumothorax was developed in 85 (18.8%) out of 453 procedures. A chest tube was inserted in ten (11.7%) of them. Variables that were significantly associated with an increased risk of pneumothorax were depth of the lesion (P<0.001) and severity of the emphysema (P<0.01). Conclusion: the length of the lung parenchyma traversed during the biopsy is the predominant risk factor for pneumothorax in patients undergoing CT-guided transthoracic biopsy. The risk of pneumothorax was also increased with the severity of the emphysema around the lesion

  20. Eosinophils are rare in biopsy specimens of psoriasis vulgaris.

    Science.gov (United States)

    Rosa, Gabriela; Fernandez, Anthony P; Schneider, Sarah; Billings, Steven D

    2017-12-01

    Histological features of lesional biopsies can be helpful in distinguishing psoriasis subtypes from disease mimickers. However, occasionally, classic histological features are not sufficient for distinction, and additional clues would be useful. There is a common belief that the presence of eosinophils in skin biopsies argues against psoriasis, but actual literature is scant. Skin biopsies with a diagnosis of psoriasis from 2013 to 2016 were reviewed. For inclusion, both histological and clinical features were required to be consistent with psoriasis. For biopsies meeting inclusion criteria, a detailed evaluation for typical histological parameters of psoriasis, as well as presence of dermal eosinophils, was performed. Of 85 cases meeting inclusion criteria, all had either individual or grouped intracorneal neutrophils and dilated papillary blood vessels. Diminished or complete loss of the granular cell layer was seen in 83 cases (98%), and parakeratosis was seen in 84 cases (99%). Alternatively, dermal eosinophils were seen in only 15 cases (18%). Of cases with eosinophils, none had more than 3 eosinophils upon examination of the entire dermis. Active treatment did not appear to impact presence/absence or numbers of eosinophils. Eosinophils are uncommon in psoriasis biopsies, and when present, they are found in small numbers. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.