WorldWideScience

Sample records for stabilized optical tracking

  1. Silicon retina for optical tracking systems

    Science.gov (United States)

    Strohbehn, K.; Jenkins, R. E.; Sun, X.; Andreou, A. G.

    1993-01-01

    There are a host of position sensors, such as quadcells and CCD's, which are candidates for detecting optical position errors and providing error signals for a mirror positioning loop. We are developing a novel, very high bandwidth, biologically inspired position sensor for optical position tracking systems. We present recent test results and design issues for the use of biologically inspired silicon retinas for spaceborne optical position tracking systems.

  2. The forward tracking, an optical model method

    CERN Document Server

    Benayoun, M

    2002-01-01

    This Note describes the so-called Forward Tracking, and the underlying optical model, developed in the context of LHCb-Light studies. Starting from Velo tracks, cheated or found by real pattern recognition, the tracks are found in the ST1-3 chambers after the magnet. The main ingredient to the method is a parameterisation of the track in the ST1-3 region, based on the Velo track parameters and an X seed in one ST station. Performance with the LHCb-Minus and LHCb-Light setups is given.

  3. Electro-Optical Data Acquisition and Tracking System

    Data.gov (United States)

    Federal Laboratory Consortium — The Electro-Optical Data Acquisition and Tracking System (EDATS) dynamically tracks and measures target signatures. It consists of an instrumentation van integrated...

  4. Gyroscopically Stabilized Robot: Balance and Tracking

    Directory of Open Access Journals (Sweden)

    Yongsheng Ou

    2008-11-01

    Full Text Available The single wheel, gyroscopically stabilized robot - Gyrover, is a dynamically stable but statically unstable, underactuated system. In this paper, based on the dynamic model of the robot, we investigate two classes of nonholonomic constraints associated with the system. Then, based on the backstepping technology, we propose a control law for balance control of Gyrover. Next, through transferring the systems states from Cartesian coordinate to polar coordinate, control laws for point-to-point control and line tracking in Cartesian space are provided.

  5. Gyroscopically Stabilized Robot: Balance and Tracking

    Directory of Open Access Journals (Sweden)

    Yongsheng Ou

    2004-03-01

    Full Text Available The single wheel, gyroscopically stabilized robot - Gyrover, is a dynamically stable but statically unstable, underactuated system. In this paper, based on the dynamic model of the robot, we investigate two classes of nonholonomic constraints associated with the system. Then, based on the backstepping technology, we propose a control law for balance control of Gyrover. Next, through transferring the systems states from Cartesian coordinate to polar coordinate, control laws for point-to-point control and line tracking in Cartesian space are provided.

  6. Self-tracking optical beam monitor

    International Nuclear Information System (INIS)

    Miyahara, T.; Mitsuhashi, T.

    1992-01-01

    A new optical beam monitor with a self-tracking system was constructed and tested at an undulator beam line of the Photon Factory. The monitor has a feedback system to receive a constant part of the radiation and gives a large range of linearity. The beam position is read out through a linear encoder to detect the self-tracking movement of a pair of photocathodes. The monitor except the feedback system is totally bakeable and UHV compatible and can be installed at a VUV or a soft x-ray beam line

  7. Optical Recognition And Tracking Of Objects

    Science.gov (United States)

    Chao, Tien-Hsin; Liu, Hua-Kuang

    1988-01-01

    Separate objects moving independently tracked simultaneously. System uses coherent optical techniques to obtain correlation between each object and reference image. Moving objects monitored by charge-coupled-device television camera, output fed to liquid-crystal television (LCTV) display. Acting as spatial light modulator, LCTV impresses images of moving objects on collimated laser beam. Beam spatially low-pass filtered to remove high-spatial-frequency television grid pattern.

  8. Optical Tracking Technology in Stereotactic Radiation Therapy

    International Nuclear Information System (INIS)

    Wagner, Thomas H.; Meeks, Sanford L.; Bova, Frank J.; Friedman, William A.; Willoughby, Twyla R.; Kupelian, Patrick A.; Tome, Wolfgang

    2007-01-01

    The last decade has seen the introduction of advanced technologies that have enabled much more precise application of therapeutic radiation. These relatively new technologies include multileaf collimators, 3-dimensional conformal radiotherapy planning, and intensity modulated radiotherapy in radiotherapy. Therapeutic dose distributions have become more conformal to volumes of disease, sometimes utilizing sharp dose gradients to deliver high doses to target volumes while sparing nearby radiosensitive structures. Thus, accurate patient positioning has become even more important, so that the treatment delivered to the patient matches the virtual treatment plan in the computer treatment planning system. Optical and image-guided radiation therapy systems offer the potential to improve the precision of patient treatment by providing a more robust fiducial system than is typically used in conventional radiotherapy. The ability to accurately position internal targets relative to the linac isocenter and to provide real-time patient tracking theoretically enables significant reductions in the amount of normal tissue irradiated. This report reviews the concepts, technology, and clinical applications of optical tracking systems currently in use for stereotactic radiation therapy. Applications of radiotherapy optical tracking technology to respiratory gating and the monitoring of implanted fiducial markers are also discussed

  9. Stability of miniature electromagnetic tracking systems

    International Nuclear Information System (INIS)

    Schicho, Kurt; Figl, Michael; Donat, Markus; Birkfellner, Wolfgang; Seemann, Rudolf; Wagner, Arne; Bergmann, Helmar; Ewers, Rolf

    2005-01-01

    This study aims at a comparative evaluation of two recently introduced electromagnetic tracking systems under reproducible simulated operating-room (OR) conditions: the recently launched Medtronic StealthStation TM Treon-EM TM and the NDI Aurora TM . We investigate if and to what extent these systems provide improved performance and stability in the presence of surgical instruments as possible sources of distortions compared with earlier reports on electromagnetic tracking technology. To investigate possible distortions under pseudo-realistic OR conditions, a large Langenbeck hook, a dental drill with its handle and an ultrasonic (US) scanhead are fixed on a special measurement rack at variable distances from the navigation sensor. The position measurements made by the Treon-EM TM were least affected by the presence of the instruments. The lengths of the mean deviation vectors were 0.21 mm for the Langenbeck hook, 0.23 mm for the drill with handle and 0.56 mm for the US scanhead. The Aurora TM was influenced by the three sources of distortion to a higher degree. A mean deviation vector of 1.44 mm length was observed in the vicinity of the Langenbeck hook, 0.53 mm length with the drill and 2.37 mm due to the US scanhead. The maximum of the root mean squared error (RMSE) for all coordinates in the presence of the Langenbeck hook was 0.3 mm for the Treon TM and 2.1 mm for the Aurora TM ; the drill caused a maximum RMSE of 0.2 mm with the Treon TM and 1.2 mm with the Aurora TM . In the presence of the US scanhead, the maximum RMSE was 1.4 mm for the Treon TM and 5.1 mm for the Aurora TM . The new generation of electromagnetic tracking systems has significantly improved compared to common systems that were available in the middle of the 1990s and has reached a high level of technical development. We conclude that, in general, both systems are suitable for routine clinical application

  10. Optical metrology techniques for dimensional stability measurements

    NARCIS (Netherlands)

    Ellis, Jonathan David

    2010-01-01

    This thesis work is optical metrology techniques to determine material stability. In addition to displacement interferometry, topics such as periodic nonlinearity, Fabry-Perot interferometry, refractometry, and laser stabilization are covered.

  11. Automated Mulitple Object Optical Tracking and Recognition System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — OPTRA proposes to develop an optical tracking system that is capable of recognizing and tracking up to 50 different objects within an approximately 2 degree x 3...

  12. Automated Mulitple Object Optical Tracking and Recognition System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — OPTRA proposes to develop an optical tracking system that is capable of recognizing and tracking up to 50 different objects within an approximately 2 degree x 3...

  13. Stabilizing Fiber-Optic Transmission Lines

    Science.gov (United States)

    Lutes, G. F.; Lau, K. Y.

    1984-01-01

    Voltage-controlled optical phase shifter is key. Optical phase shifter stabilizes propagation delay of fiber-optic transmission line by compensating for temperature and pressure effects. Applicable to phased array antenna systems and very-long-baseline interferometer distribution systems.

  14. GOCE SSTI Tracking Stability and Accuracy

    Science.gov (United States)

    Niemann, Peter; Frommknecht, Bjorn; Thor, Robin

    2015-03-01

    The GOCE SSTI GPS receiver instruments experienced significant tracking losses throughout the mission. The geolocation of such tracking losses is strongly correlated with the location of magnetic equator and poles. Auroral and equatorial tracking losses exhibit different characteristics. During the final four months of the GOCE mission, the two on-board SSTI instruments were operated in parallel with different configurations. We use differences and correlations in the observations of the two instruments in order to derive: * The significance of equipment configuration in the occurrence of tracking loss incidents; * Significant biases in the measurements generated by the specifics of the GOCE orbit; * Evidence of phase and amplitude scintillation within the measurements. We evaluate the impact on the GOCE Level 1b position, velocity and clock product. The inclusion of SSTI-B additional measurements, or the inclusion of single frequency observations, results in significant degradations of the product in areas of ionospheric irregularities.

  15. Optical Coherence Tomography for Tracking Canvas Deformation

    International Nuclear Information System (INIS)

    Targowski, P.; Gora, M.; Bajraszewski, T.; Szkulmowski, M.; Rouba, B.; Lekawa-Wyslouch, T.; Tyminska-Widmer, L.

    2006-01-01

    Preliminary results of the application of optical coherence tomography (OCT), in particular in its spectral mode (SOCT), to tracking of deformations in paintings on canvas caused by periodical humidity changes are presented. The setup is able to monitor the position of a chosen point at the surface of a painting with micrometre precision, simultaneously in three dimensions, every 100 seconds. This allows recording of deformations associated with crack formation. For the particular painting model examined, it was shown that the surface moves in-plane towards the corner, and bulges outwards (Z-direction) in response to a rise in humidity. Subsequent to the first humidification/drying cycle, translation in the Z-direction is decreased, whilst in-plane translations increase somewhat. It was also shown that the response of the painting on canvas begins immediately on changing the relative humidity in the surroundings.

  16. High-stability 48-core bendable and movable optical cable for FAST telescope optical transmission system

    Science.gov (United States)

    Liu, Hongfei; Pan, Gaofeng; Lin, Zhong; Liu, Cheng; Zhu, Wenbai; Nan, Rendong; Li, Chunsheng; Gao, Guanjun; Luo, Wenyong; Jin, Chengjin; Song, Jinyou

    2017-11-01

    The construction of FAST telescope was completed in Guizhou province of China in September 2016, and a kind of novel high-stability 48-core bendable and movable optical cable was developed and applied in analog data optical transmission system of FAST. Novel structure and selective material of this optical cable ensure high stability of optical power in the process of cables round-trip motion when telescope is tracking a radio source. The 105 times bend and stretch accelerated experiment for this optical cable was implemented, and real-time optical and RF signal power fluctuation were measured. The physical structure of optical cables after 105 times round-trip motion is in good condition; the real-time optical power attenuation fluctuation is smaller than 0.044 dB; the real-time RF power fluctuation is smaller than 0.12 dB. The optical cable developed in this letter meets the requirement of FAST and has been applied in FAST telescope.

  17. Stability and manoeuvrability characteristics of single track vehicles.

    NARCIS (Netherlands)

    Godthelp, J. & Buist, M.

    1975-01-01

    An investigation was carried out concerning stability and manoeuvrability characteristics of single track vehicles. This report deals with the first phase of this study and refers to experiments carried out(1) with an instrumented varied and (2) with a number of popular bicycles and mopeds. In

  18. Stabilized Optical Fiber Links for the XFEL

    CERN Document Server

    Winter, Axel; Grawert, Felix J; Ilday, Fatih O; Kaertner, Franz X; Kim, Jung-Won; Schlarb, Holger; Schmidt, Bernhard

    2005-01-01

    The timing synchronization scheme for the European X-Ray free electron laser facility (XFEL) is based on the generation and distribution of sub-picosecond laser pulses with actively stabilized repetition rate which are used to synchronize local RF oscillators. An integral part of the scheme is the distribution of the optical pulse stream to parts of the facility via optical fiber links. The optical path length of the fiber has to be stabilized against short-term and long-term timing jitter due to environmental effects, such as temperature drifts and acoustic vibrations, to better than 10 fs for distances ranging from tens of meters to several kilometers. In this paper, we present first experimental results for signal transmission through a km-long fiber link with femtosecond stability.

  19. Optical stabilization for time transfer infrastructure

    Science.gov (United States)

    Vojtech, Josef; Altmann, Michal; Skoda, Pavel; Horvath, Tomas; Slapak, Martin; Smotlacha, Vladimir; Havlis, Ondrej; Munster, Petr; Radil, Jan; Kundrat, Jan; Altmannova, Lada; Velc, Radek; Hula, Miloslav; Vohnout, Rudolf

    2017-08-01

    In this paper, we propose and present verification of all-optical methods for stabilization of the end-to-end delay of an optical fiber link. These methods are verified for deployment within infrastructure for accurate time and stable frequency distribution, based on sharing of fibers with research and educational network carrying live data traffic. Methods range from path length control, through temperature conditioning method to transmit wavelength control. Attention is given to achieve continuous control for relatively broad range of delays. We summarize design rules for delay stabilization based on the character and the total delay jitter.

  20. Three dimensional tracking for volumetric spectral-domain optical coherence tomography.

    Science.gov (United States)

    Maguluri, Gopi; Mujat, Mircea; Park, B H; Kim, K H; Sun, Wei; Iftimia, N V; Ferguson, R D; Hammer, Daniel X; Chen, Teresa C; de Boer, Johannes F

    2007-12-10

    We present a three-dimensional (3D) tracker for a clinical ophthalmic spectral domain optical coherence tomography (SD-OCT) system that combines depth-tracking with lateral tracking, providing a stabilized reference frame for 3D data recording and post acquisition analysis. The depth-tracking system is implemented through a real-time dynamic feedback mechanism to compensate for motion artifact in the axial direction. Active monitoring of the retina and adapting the reference arm of the interferometer allowed the whole thickness of the retina to be stabilized to within +/-100 mum. We achieve a relatively constant SNR from image to image by stabilizing the image of the retina with respect to the depth dependent sensitivity of SD-OCT. The depth tracking range of our system is 5.2 mm in air and the depth is adjusted every frame.nhancement in the stability of the images with the depth-tracking algorithm is demonstrated on a healthy volunteer.

  1. An optical processor for object recognition and tracking

    Science.gov (United States)

    Sloan, J.; Udomkesmalee, S.

    1987-01-01

    The design and development of a miniaturized optical processor that performs real time image correlation are described. The optical correlator utilizes the Vander Lugt matched spatial filter technique. The correlation output, a focused beam of light, is imaged onto a CMOS photodetector array. In addition to performing target recognition, the device also tracks the target. The hardware, composed of optical and electro-optical components, occupies only 590 cu cm of volume. A complete correlator system would also include an input imaging lens. This optical processing system is compact, rugged, requires only 3.5 watts of operating power, and weighs less than 3 kg. It represents a major achievement in miniaturizing optical processors. When considered as a special-purpose processing unit, it is an attractive alternative to conventional digital image recognition processing. It is conceivable that the combined technology of both optical and ditital processing could result in a very advanced robot vision system.

  2. Simultaneous Electro-Optical Tracking for Nanoparticle Recognition and Counting.

    Science.gov (United States)

    Angeli, Elena; Volpe, Andrea; Fanzio, Paola; Repetto, Luca; Firpo, Giuseppe; Guida, Patrizia; Lo Savio, Roberto; Wanunu, Meni; Valbusa, Ugo

    2015-09-09

    We present the first detailed experimental observation and analysis of nanoparticle electrophoresis through a nanochannel obtained with synchronous high-bandwidth electrical and camera recordings. Optically determined particle diffusion coefficients agree with values extracted from fitting electrical transport measurements to distributions from 1D Fokker-Planck diffusion-drift theory. This combined tracking strategy enables optical recognition and electrical characterization of nanoparticles in solution, which can have a broad range of applications in biology and materials science.

  3. Tracking nanoparticles in an optical microscope using caustics

    International Nuclear Information System (INIS)

    Patterson, Eann A; Whelan, Maurice P

    2008-01-01

    An elegant method is proposed and demonstrated for tracking the location and movement of nanoparticles in an optical microscope using the optical phenomenon of caustics. A simple and reversible adjustment to the microscope generates caustics several orders of magnitude larger than the particles. The method offers a simple and relatively inexpensive method for visualizing such phenomena as the formation of self-assembled monolayers and the interaction of nanoparticles with chemically functionalized surfaces

  4. Tracking nanoparticles in an optical microscope using caustics

    Energy Technology Data Exchange (ETDEWEB)

    Patterson, Eann A [Department of Mechanical Engineering, Michigan State University, East Lansing, MI 48824 (United States); Whelan, Maurice P [Nanotechnology and Molecular Imaging Unit, Institute for Health and Consumer Protection, European Commission DG Joint Research Center, 21021 Ispra (Vatican City State, Holy See,) (Italy)

    2008-03-12

    An elegant method is proposed and demonstrated for tracking the location and movement of nanoparticles in an optical microscope using the optical phenomenon of caustics. A simple and reversible adjustment to the microscope generates caustics several orders of magnitude larger than the particles. The method offers a simple and relatively inexpensive method for visualizing such phenomena as the formation of self-assembled monolayers and the interaction of nanoparticles with chemically functionalized surfaces.

  5. Reactive granular optics for passive tracking of the sun

    Science.gov (United States)

    Frenkel, I.; Niv, A.

    2017-08-01

    The growing need for cost-effective renewable energy sources is hampered by the stagnation in solar cell technology, thus preventing a substantial reduction in the module and energy-production price. Lowering the energy-production cost could be achieved by using modules with efficiency. One of the possible means for increasing the module efficiency is concentrated photovoltaics (CPV). CPV, however, requires complex and accurate active tracking of the sun that reduces much of its cost-effectiveness. Here, we propose a passive tracking scheme based on a reactive optical device. The optical reaction is achieved by a new kind of light activated mechanical force that acts on micron-sized particles. This optical force allows the formation of granular disordered optical media that can be switched from being opaque to become transparent based on the intensity of light it interacts with. Such media gives rise to an efficient passive tracking scheme that when combined with an external optical cavity forms a new solar power conversion approach. Being external to the cell itself, this approach is indifferent to the type of semiconducting material that is used, as well as to other aspects of the cell design. This, in turn, liberates the cell layout from its optical constraints thus paving the way to higher efficiencies at lower module price.

  6. Automatic Optical Crack Tracking for Double Cantilever Beam Specimens

    Science.gov (United States)

    2015-01-01

    and Member, R.G., ‘‘Path Planning For Machine Vision Assisted, Teleoperated Pavement Crack Sealer,’’ Journal of Transportation Engineering 124:137...TECHN ICAL ART IC LE Automatic Optical Crack Tracking for Double Cantilever Beam Specimens B. Krull1,2, J. Patrick2,3, K. Hart2,4, S. White2,4, and N...accepted: January 31, 2015 doi:10.1111/ext.12148 Abstract An automatic crack tracking scheme is developed for measuring the tensile opening (mode I

  7. Tracking integration in concentrating photovoltaics using laterally moving optics.

    Science.gov (United States)

    Duerr, Fabian; Meuret, Youri; Thienpont, Hugo

    2011-05-09

    In this work the concept of tracking-integrated concentrating photovoltaics is studied and its capabilities are quantitatively analyzed. The design strategy desists from ideal concentration performance to reduce the external mechanical solar tracking effort in favor of a compact installation, possibly resulting in lower overall cost. The proposed optical design is based on an extended Simultaneous Multiple Surface (SMS) algorithm and uses two laterally moving plano-convex lenses to achieve high concentration over a wide angular range of ±24°. It achieves 500× concentration, outperforming its conventional concentrating photovoltaic counterparts on a polar aligned single axis tracker.

  8. Fast left ventricle tracking using localized anatomical affine optical flow.

    Science.gov (United States)

    Queirós, Sandro; Vilaça, João L; Morais, Pedro; Fonseca, Jaime C; D'hooge, Jan; Barbosa, Daniel

    2017-11-01

    In daily clinical cardiology practice, left ventricle (LV) global and regional function assessment is crucial for disease diagnosis, therapy selection, and patient follow-up. Currently, this is still a time-consuming task, spending valuable human resources. In this work, a novel fast methodology for automatic LV tracking is proposed based on localized anatomically constrained affine optical flow. This novel method can be combined to previously proposed segmentation frameworks or manually delineated surfaces at an initial frame to obtain fully delineated datasets and, thus, assess both global and regional myocardial function. Its feasibility and accuracy were investigated in 3 distinct public databases, namely in realistically simulated 3D ultrasound, clinical 3D echocardiography, and clinical cine cardiac magnetic resonance images. The method showed accurate tracking results in all databases, proving its applicability and accuracy for myocardial function assessment. Moreover, when combined to previous state-of-the-art segmentation frameworks, it outperformed previous tracking strategies in both 3D ultrasound and cardiac magnetic resonance data, automatically computing relevant cardiac indices with smaller biases and narrower limits of agreement compared to reference indices. Simultaneously, the proposed localized tracking method showed to be suitable for online processing, even for 3D motion assessment. Importantly, although here evaluated for LV tracking only, this novel methodology is applicable for tracking of other target structures with minimal adaptations. Copyright © 2017 John Wiley & Sons, Ltd.

  9. The Enhancement of Target Localization Using Ship-Borne Electro-Optical Stabilized Platform

    OpenAIRE

    Jaehoon Ha; Byungmo Kang; Kilho Hong; Jungsoo Park

    2016-01-01

    Electro-optical (EO) stabilized platforms have been widely used for surveillance and reconnaissance on various types of vehicles, from surface ships to unmanned air vehicles (UAVs). EO stabilized platforms usually consist of an assembly of structure, bearings, and motors called gimbals in which a gyroscope is installed. EO elements such as a CCD camera and IR camera, are mounted to a gimbal, which has a range of motion in elevation and azimuth and can designate and track a target. In addition...

  10. Adaptive optics with pupil tracking for high resolution retinal imaging.

    Science.gov (United States)

    Sahin, Betul; Lamory, Barbara; Levecq, Xavier; Harms, Fabrice; Dainty, Chris

    2012-02-01

    Adaptive optics, when integrated into retinal imaging systems, compensates for rapidly changing ocular aberrations in real time and results in improved high resolution images that reveal the photoreceptor mosaic. Imaging the retina at high resolution has numerous potential medical applications, and yet for the development of commercial products that can be used in the clinic, the complexity and high cost of the present research systems have to be addressed. We present a new method to control the deformable mirror in real time based on pupil tracking measurements which uses the default camera for the alignment of the eye in the retinal imaging system and requires no extra cost or hardware. We also present the first experiments done with a compact adaptive optics flood illumination fundus camera where it was possible to compensate for the higher order aberrations of a moving model eye and in vivo in real time based on pupil tracking measurements, without the real time contribution of a wavefront sensor. As an outcome of this research, we showed that pupil tracking can be effectively used as a low cost and practical adaptive optics tool for high resolution retinal imaging because eye movements constitute an important part of the ocular wavefront dynamics.

  11. Transient stability improvement by nonlinear controllers based on tracking

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, Juan M. [Centro de Investigacion y Estudios Avanzados, Guadalajara, Mexico. Av. Cientifica 1145. Col. El Bajio. Zapopan, Jal. 45015 (Mexico); Arroyave, Felipe Valencia; Correa Gutierrez, Rosa Elvira [Universidad Nacional de Colombia, Sede Medellin. Facultad de Minas, Escuela de Mecatronica (Colombia)

    2011-02-15

    This paper deals with the control problem in multi-machine electric power systems, which represent complex great scale nonlinear systems. Thus, the controller design is a challenging problem. These systems are subjected to different perturbations, such as short circuits, connection and/or disconnection of loads, lines, or generators. Then, the utilization of controllers which guarantee good performance under those perturbations is required in order to provide electrical energy to the loads with admissible stability margins. The proposed controllers are based on a systematic strategy, which calculate nonlinear controllers for generating units in a power plant, both for voltage and velocity regulation. The formulation allows designing controllers in a multi-machine power system without intricate calculations. Results on a power system of the open research indicate the proposition's suitability. The problem is formulated as a tracking problem. The designed controllers may be implemented in any electric power system. (author)

  12. Square tracking sensor for autonomous helicopter hover stabilization

    Science.gov (United States)

    Oertel, Carl-Henrik

    1995-06-01

    Sensors for synthetic vision are needed to extend the mission profiles of helicopters. A special task for various applications is the autonomous position hold of a helicopter above a ground fixed or moving target. As a proof of concept for a general synthetic vision solution a restricted machine vision system, which is capable of locating and tracking a special target, was developed by the Institute of Flight Mechanics of Deutsche Forschungsanstalt fur Luft- und Raumfahrt e.V. (i.e., German Aerospace Research Establishment). This sensor, which is specialized to detect and track a square, was integrated in the fly-by-wire helicopter ATTHeS (i.e., Advanced Technology Testing Helicopter System). An existing model following controller for the forward flight condition was adapted for the hover and low speed requirements of the flight vehicle. The special target, a black square with a length of one meter, was mounted on top of a car. Flight tests demonstrated the automatic stabilization of the helicopter above the moving car by synthetic vision.

  13. Automatic respiration tracking for radiotherapy using optical 3D camera

    Science.gov (United States)

    Li, Tuotuo; Geng, Jason; Li, Shidong

    2013-03-01

    Rapid optical three-dimensional (O3D) imaging systems provide accurate digitized 3D surface data in real-time, with no patient contact nor radiation. The accurate 3D surface images offer crucial information in image-guided radiation therapy (IGRT) treatments for accurate patient repositioning and respiration management. However, applications of O3D imaging techniques to image-guided radiotherapy have been clinically challenged by body deformation, pathological and anatomical variations among individual patients, extremely high dimensionality of the 3D surface data, and irregular respiration motion. In existing clinical radiation therapy (RT) procedures target displacements are caused by (1) inter-fractional anatomy changes due to weight, swell, food/water intake; (2) intra-fractional variations from anatomy changes within any treatment session due to voluntary/involuntary physiologic processes (e.g. respiration, muscle relaxation); (3) patient setup misalignment in daily reposition due to user errors; and (4) changes of marker or positioning device, etc. Presently, viable solution is lacking for in-vivo tracking of target motion and anatomy changes during the beam-on time without exposing patient with additional ionized radiation or high magnet field. Current O3D-guided radiotherapy systems relay on selected points or areas in the 3D surface to track surface motion. The configuration of the marks or areas may change with time that makes it inconsistent in quantifying and interpreting the respiration patterns. To meet the challenge of performing real-time respiration tracking using O3D imaging technology in IGRT, we propose a new approach to automatic respiration motion analysis based on linear dimensionality reduction technique based on PCA (principle component analysis). Optical 3D image sequence is decomposed with principle component analysis into a limited number of independent (orthogonal) motion patterns (a low dimension eigen-space span by eigen-vectors). New

  14. Capturing Revolute Motion and Revolute Joint Parameters with Optical Tracking

    Science.gov (United States)

    Antonya, C.

    2017-12-01

    Optical tracking of users and various technical systems are becoming more and more popular. It consists of analysing sequence of recorded images using video capturing devices and image processing algorithms. The returned data contains mainly point-clouds, coordinates of markers or coordinates of point of interest. These data can be used for retrieving information related to the geometry of the objects, but also to extract parameters for the analytical model of the system useful in a variety of computer aided engineering simulations. The parameter identification of joints deals with extraction of physical parameters (mainly geometric parameters) for the purpose of constructing accurate kinematic and dynamic models. The input data are the time-series of the marker’s position. The least square method was used for fitting the data into different geometrical shapes (ellipse, circle, plane) and for obtaining the position and orientation of revolute joins.

  15. Comparison of SEM and Optical Analysis of DT Neutron Tracks in CR-39 Detectors

    Energy Technology Data Exchange (ETDEWEB)

    P.A. Mosier-Boss, L.P.G. Forsley, P. Carbonnelle, M.S. Morey, J.R. Tinsley, J. P. Hurley, F.E. Gordon

    2012-01-01

    A solid state nuclear track detector, CR-39, was exposed to DT neutrons. After etching, the resultant tracks were analyzed using both an optical microscope and a scanning electron microscope (SEM). In this communication, both methods of analyzing DT neutron tracks are discussed.

  16. Research on Dynamics and Stability in the Stairs-Climbing of a Tracked Mobile Robot

    Directory of Open Access Journals (Sweden)

    Weijun Tao

    2012-10-01

    Full Text Available Aiming at the functional requirement of climbing up the stairs, the dynamics and stability during a tracked mobile robot's climbing of stairs is studied. First, from the analysis of its cross-country performance, the mechanical structure of the tracked mobile robot is designed and the hardware composition of its control system is given. Second, based on the analysis to its stairs-climbing process, the dynamical model of stairs-climbing is established by using the classical mechanics method. Next, the stability conditions for its stairs-climbing are determined and an evaluation method of its stairs-climbing stability is proposed, based on a mechanics analysis on the robot's backwards tumbling during the stairs-climbing process. Through simulation and experiments, the effectiveness of the dynamical model and the stability evaluation method of the tracked mobile robot in stairs-climbing is verified, which can provide design and analysis foundations for the tracked mobile robots' stairs-climbing.

  17. An image stabilization optical system using deformable freeform mirrors.

    Science.gov (United States)

    Hao, Qun; Cheng, Xuemin; Kang, Jiqiang; Jiang, Yuhua

    2015-01-15

    An image stabilization optical system using deformable freeform mirrors is proposed that enables the ray sets to couple dynamically in the object and image space. It aims to correct image blurring and degradation when there is relative movement between the imaging optical axis and the object. In this method, Fermat's principle and matrix methods are used to describe the optical path of the entire optical system with a shift object plane and a fixed corresponding image plane in the carrier coordinate system. A constant optical path length is determined for each ray set, so the correspondence between the object and the shift free image point is used to calculate the solution to the points on the surface profile of the deformable mirrors (DMs). Off-axis three-mirror anastigmats are used to demonstrate the benefits of optical image stabilization with one- and two-deformable mirrors.

  18. Trajectory Tracking and Stabilization of a Quadrotor Using Model Predictive Control of Laguerre Functions

    Directory of Open Access Journals (Sweden)

    Mapopa Chipofya

    2015-01-01

    Full Text Available This paper presents a solution to stability and trajectory tracking of a quadrotor system using a model predictive controller designed using a type of orthonormal functions called Laguerre functions. A linear model of the quadrotor is derived and used. To check the performance of the controller we compare it with a linear quadratic regulator and a more traditional linear state space MPC. Simulations for trajectory tracking and stability are performed in MATLAB and results provided in this paper.

  19. An Optical Tracking System based on Hybrid Stereo/Single-View Registration and Controlled Cameras

    OpenAIRE

    Cortes , Guillaume; Marchand , Eric; Ardouin , Jérôme; Lécuyer , Anatole

    2017-01-01

    International audience; Optical tracking is widely used in robotics applications such as unmanned aerial vehicle (UAV) localization. Unfortunately, such systems require many cameras and are, consequently, expensive. In this paper, we propose an approach to considerably increase the optical tracking volume without adding cameras. First, when the target becomes no longer visible by at least two cameras we propose a single-view tracking mode which requires only one camera. Furthermore, we propos...

  20. Climate stability and cloud optical thickness feedbacks

    Science.gov (United States)

    Somerville, Richard C. J.; Iacobellis, Sam

    1989-01-01

    An improved radiative-convective model (RCM) has been developed and used to examine the role of cirrus clouds in the optical thickness feedback mechanism. Low and middle clouds are approximately black bodies for infrared radiative transfer, and so any increase in their optical thickness primarily increases the cloud albedo. Thus, if a climate warming is accompanied by an increase in average atmospheric absolute humidity and hence in average cloud liquid water content, low and middle cloud optical thickness and albedo may increase. The result is a negative feedback on the climate change, tending to reduce the surface temperature increase. Recent research suggests that the optical thickness feedback can depend sensitively on aspects of cirrus which are not well observed or adequately incorporated in typical present-day climate models.

  1. Stability control for high speed tracked unmanned vehicles

    Science.gov (United States)

    Pape, Olivier; Morillon, Joel G.; Houbloup, Philippe; Leveque, Stephane; Fialaire, Cecile; Gauthier, Thierry; Ropars, Patrice

    2005-05-01

    The French Military Robotic Study Program (introduced in Aerosense 2003), sponsored by the French Defense Procurement Agency and managed by Thales as the prime contractor, focuses on about 15 robotic themes which can provide an immediate "operational add-on value". The paper details the "automatic speed adjustment" behavior (named SYR4), developed by Giat Industries Company, which main goal is to secure the teleoperated mobility of high speed tracked vehicles on rough grounds; more precisely, the validated low level behavior continuously adjusts the vehicle speed taking into account the teleperator wish AND the maximum speed that the vehicle can manage safely according to the commanded radius of curvature. The algorithm is based on a realistic physical model of the ground-tracks relation, taking into account many vehicle and ground parameters (such as ground adherence and dynamic specificities of tracked vehicles). It also deals with the teleoperator-machine interface, providing a balanced strategy between both extreme behaviors: a) maximum speed reduction before initiating the commanded curve; b) executing the minimum possible radius without decreasing the commanded speed. The paper presents the results got from the military acceptance tests performed on tracked SYRANO vehicle (French Operational Demonstrator).

  2. PolarTrack: Optical Outside-In Device Tracking that Exploits Display Polarization

    DEFF Research Database (Denmark)

    Rädle, Roman; Jetter, Hans-Christian; Fischer, Jonathan

    2018-01-01

    PolarTrack is a novel camera-based approach to detecting and tracking mobile devices inside the capture volume. In PolarTrack, a polarization filter continuously rotates in front of an off-the-shelf color camera, which causes the displays of observed devices to periodically blink in the camera feed....... The periodic blinking results from the physical characteristics of current displays, which shine polarized light either through an LC overlay to produce images or through a polarizer to reduce light reflections on OLED displays. PolarTrack runs a simple detection algorithm on the camera feed to segment...... tracking accuracy and precision with similar tracking reliability. PolarTrack works as standalone multi-device tracking but is also compatible with existing camera-based tracking systems and can complement them to compensate for their limitations....

  3. Optical tracking of local surface wave for skin viscoelasticity.

    Science.gov (United States)

    Guan, Yubo; Lu, Mingzhu; Shen, Zhilong; Wan, Mingxi

    2014-06-01

    Rapid and effective determination of biomechanical properties is important in examining and diagnosing skin thermal injury. Among the methods used, viscoelasticity quantification is one of the most effective methods in determining such properties. This study aims to rapidly determine skin viscoelasticity by optically tracking the local surface wave. New elastic and viscous coefficients were proposed to indicate skin viscoelasticity based on a single impulse response of the skin. Experiments were performed using fresh porcine skin samples. Surface wave was generated in a single impulse using a vibrator with a ball-tipped device and was detected using a laser Doppler vibrometer. The motions along the depth direction were monitored using an ultrasound system. The ultrasound monitoring results indicated the multi-layered viscoelasticity of the epidermis and dermis. The viscoelastic coefficients from four healthy samples show a potential viscoelasticity variation of porcine skin. In one sample, the two coefficients were evidently higher than those in a healthy area if the skin was slightly burned. These results indicate that the proposed method is sensitive, effective, and quick in determining skin viscoelasticity. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Automation system for optical counting of nuclear tracks

    CERN Document Server

    Boulyga, S F; Lomonosova, E M; Zhuk, I V

    1999-01-01

    An automation system consisting of the microscope, video camera and Pentium PC with frame recorder was created. The system provides counting of nuclear tracks on the SSNTD surface with a resolution of 752 x 582 points, determination of the surface area and main axis of the track. The pattern recognition program was developed for operation in Windows 3.1 (or higher) ensuring a convenient interface with the user. In a comparison of the results on automatic track counting with the more accurate hand mode it was shown that the program enables the tracks to be detected even on images with a rather high noise level. It ensures a high accuracy of track counting being comparable with the accuracy of manual counting for densities of tracks in the range of up to 2 centre dot 10 sup 5 tracks/cm sup 2. The automatic system was applied in the experimental investigation of uranium and transuranium elements.

  5. Feature tracking for automated volume of interest stabilization on 4D-OCT images

    Science.gov (United States)

    Laves, Max-Heinrich; Schoob, Andreas; Kahrs, Lüder A.; Pfeiffer, Tom; Huber, Robert; Ortmaier, Tobias

    2017-03-01

    A common representation of volumetric medical image data is the triplanar view (TV), in which the surgeon manually selects slices showing the anatomical structure of interest. In addition to common medical imaging such as MRI or computed tomography, recent advances in the field of optical coherence tomography (OCT) have enabled live processing and volumetric rendering of four-dimensional images of the human body. Due to the region of interest undergoing motion, it is challenging for the surgeon to simultaneously keep track of an object by continuously adjusting the TV to desired slices. To select these slices in subsequent frames automatically, it is necessary to track movements of the volume of interest (VOI). This has not been addressed with respect to 4DOCT images yet. Therefore, this paper evaluates motion tracking by applying state-of-the-art tracking schemes on maximum intensity projections (MIP) of 4D-OCT images. Estimated VOI location is used to conveniently show corresponding slices and to improve the MIPs by calculating thin-slab MIPs. Tracking performances are evaluated on an in-vivo sequence of human skin, captured at 26 volumes per second. Among investigated tracking schemes, our recently presented tracking scheme for soft tissue motion provides highest accuracy with an error of under 2.2 voxels for the first 80 volumes. Object tracking on 4D-OCT images enables its use for sub-epithelial tracking of microvessels for image-guidance.

  6. The HSOB GAIA: a cryogenic high stability cesic optical bench for missions requiring sub-nanometric optical stability

    Science.gov (United States)

    Courteau, Pascal; Poupinet, Anne; Kroedel, Mathias; Sarri, Giuseppe

    2017-11-01

    Global astrometry, very demanding in term of stability, requires extremely stable material for optical bench. CeSiC developed by ECM and Alcatel Alenia Space for mirrors and high stability structures, offers the best compromise in term of structural strength, stability and very high lightweight capability, with characteristics leading to be insensitive to thermo-elastic at cryogenic T°. The HSOB GAIA study realised by Alcatel Alenia Space under ESA contract aimed to design, develop and test a full scale representative High Stability Optical Bench in CeSiC. The bench has been equipped with SAGEIS-CSO laser metrology system MOUSE1, Michelson interferometer composed of integrated optics with a nm resolution. The HSOB bench has been submitted to an homogeneous T° step under vacuum to characterise the homothetic behaviour of its two arms. The quite negligible inter-arms differential measured with a nm range reproducibility, demonstrates that a complete 3D structure in CeSiC has the same CTE homogeneity as characterisation samples, fully in line with the GAIA need (1pm at 120K). This participates to the demonstration that CeSiC properties at cryogenic T° is fully appropriate to the manufacturing of complex highly stable optical structures. This successful study confirms ECM and Alcatel Alenia Space ability to define and manufacture monolithic lightweight highly stable optical structures, based on inner cells triangular design made only possible by the unique CeSiC manufacturing process.

  7. LISA telescope assembly optical stability characterization for ESA

    NARCIS (Netherlands)

    Verlaan, A.L.; Hogenhuis, H.; Pijnenburg, J.A.C.M.; Lemmen, M.H.J.; Lucarelli, S.; Scheulen, D.; Ende, D.

    2012-01-01

    The LISA Optical Stability Characterization project is part of the LISA CTP activities to achieve the required Technonlogy Readiness Level (TRL) for all of the LISA technologies used. This activity aims demonstration of the Telescope Assembly (TA), with a structure based on CFRP technology, that a

  8. Radiolytic stabilization on optical properties of polycarbonate

    International Nuclear Information System (INIS)

    Ferreira, Carlas P.R.C.; Araujo, Elmo S.; Aquino, Katia A.S.

    2011-01-01

    Polycarbonate (PC) is an engineering plastic widely used in several industrial segments. However, in medical applications, this material is required to be sterilized by ionizing radiation in doses of 25kGy. PC, when gamma irradiated, undergoes main chain scissions with consequent formation of phenoxy and phenyl radicals. The former remains trapped into the polymer matrix causing undesirable yellowness on material at room temperature. A strategy to minimize such effect is to incorporate additives into the polymer system enabling efficient phenoxy radicals and secondary electrons scavenging. Our results show that, in absorbed dose of 25kGy, change in yellowness index (ΔΥI) decreases from 15.6 to 3.9 for PC containing 0.8% of additives. The color differences (ΔE *) between the non-irradiated sample and that irradiated at 25kGy were 2.4 and 9.8, for PC with additive and PC control, respectively. Mechanical properties of gamma-irradiated PC were also evaluated and showed no significant change, even without stabilizing additives. Thus, this work establishes a new PC formulation stable to gamma irradiation at sterilizing absorbed doses. (author)

  9. Compact Optical Inertial Tracking for Launch Vehicles Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose a method for developing a miniature all-optical Inertial Navigation System. In an optical INS, the rotation sensitivity depends on the area enclosed by a...

  10. Performance of resonator fiber optic gyroscope using external-cavity laser stabilization and optical filtering

    Science.gov (United States)

    Qiu, Tiequn; Wu, Jianfeng; Strandjord, Lee K.; Sanders, Glen A.

    2014-05-01

    A bench-top resonator fiber optic gyroscope (RFOG) was assembled and tested, showing encouraging progress toward navigation grade performance. The gyro employed a fiber length of 19 meters of polarizing fiber for the sensing coil which was wound on an 11.5 cm diameter PZT cylinder. A bias stability of approximately 0.1 deg/hr was observed over a 2 hour timeframe, which is the best bias stability reported to date in an RFOG to our knowledge. Special care was taken to minimize laser phase noise, including stabilization to an optical cavity which was also used for optical filtering, giving angle random walk (ARW) values in the range of 0.008 deg/rt-hr. The ARW performance and bias stability are within 2x and 10x, respectively, of many civil inertial navigation grade requirements.

  11. Fusion of optical flow based motion pattern analysis and silhouette classification for person tracking and detection

    NARCIS (Netherlands)

    Tangelder, J.W.H.; Lebert, E.; Burghouts, G.J.; Zon, K. van; Den Uyl, M.J.

    2014-01-01

    This paper presents a novel approach to detect persons in video by combining optical flow based motion analysis and silhouette based recognition. A new fast optical flow computation method is described, and its application in a motion based analysis framework unifying human tracking and detection is

  12. Numerical simulation of eigenmodes of ring and race-track optical microresonators

    Science.gov (United States)

    Raskhodchikov, A. V.; Raskhodchikov, D. V.; Scherbak, S. A.; Lipovskii, A. A.

    2017-11-01

    We have performed a numerical study of whispering gallery modes of ring and race-track optical microresonators. Mode excitation was considered and their spectra and electromagnetic field distributions were calculated via numerical solution of the Helmholtz equation. We pay additional attention to features of eigenmodes in race-tracks in contrast with ring resonators. Particularly, we demonstrate that modes in race-tracks are not “classic” WGM in terms of total internal reflection from a single boundary, and an inner boundary is essential for their formation. The dependence of effective refractive index of race-tracks modes on the resonator width is shown.

  13. Feedback module for evaluating optical-power stabilization methods

    Science.gov (United States)

    Downing, John

    2016-03-01

    A feedback module for evaluating the efficacy of optical-power stabilization without thermoelectric coolers (TECs) is described. The module comprises a pickoff optic for sampling a light beam, a photodiode for converting the sample power to electrical current, and a temperature sensor. The components are mounted on an optical bench that makes accurate (0.05°) beam alignment practical as well as providing high thermal-conductivity among the components. The module can be mounted on existing light sources or the components can be incorporated in new designs. Evaluations of optical and electronic stabilization methods are also reported. The optical method combines a novel, weakly reflective, weakly polarizing coating on the pickoff optic with a photodiode and an automatic-power-control (APC) circuit in a closed loop. The shift of emitter wavelength with temperature, coupled with the wavelength-dependent reflectance of the pickoff optic, enable the APC circuit to compensate for temperature errors. In the electronic method, a mixed-signal processor in a quasiclosed loop generates a control signal from temperature and photocurrent inputs and feeds it back to an APC circuit to compensate for temperature errors. These methods result in temperature coefficients less than 20 ppm/°C and relative rms power equal to 05% for the optical method and 0.02% for the electronic method. The later value represents an order of magnitude improvement over rms specifications for cooled, laser-diode modules and a five-fold improvement in wall-plug efficiency is achieved by eliminating TECs.

  14. Stability of matter-wave solitons in optical lattices

    Science.gov (United States)

    Ali, Sk. Golam; Roy, S. K.; Talukdar, B.

    2010-08-01

    We consider localized states of both single- and two-component Bose-Einstein condensates (BECs) confined in a potential resulting from the superposition of linear and nonlinear optical lattices and make use of Vakhitov-Kolokolov criterion to investigate the effect of nonlinear lattice on the stability of the soliton solutions in the linear optical lattice (LOL). For the single-component case we show that a weak nonlinear lattice has very little effect on the stability of such solitons while sufficiently strong nonlinear optical lattice (NOL) squeezes them to produce narrow bound states. For two-component condensates we find that when the strength of the NOL (γ1) is less than that of the LOL (V0) a relatively weak intra-atomic interaction (IAI) has little effect on the stability of the component solitons. This is true for both attractive and repulsive IAI. A strong attractive IAI, however, squeezes the BEC solitons while a similar repulsive IAI makes the component solitons wider. For γ1 > V0, only a strong attractive IAI squeezes the BEC solitons but the squeezing effect is less prominent than that found for γ1 < V0. We make useful checks on the results of our semianalytical stability analysis by solving the appropriate Gross-Pitaevskii equations numerically.

  15. Caustic meso-optical confocal microscope for vertical particle tracks. Proposal

    International Nuclear Information System (INIS)

    Soroko, L.M.

    1995-01-01

    The principal of the proposed caustic meso-optical microscope for vertical particle tracks in the nuclear photoemulsion is explained. The results of the experiments performed to illustrate the main features of this new meso-optical microscope are given. The proposed caustic meso-optical microscope for vertical particle tracks in the nuclear photoemulsion can be effectively used in the experimental investigation of such rare processes as ν μ - ν τ oscillations and of the Pb-Pb interactions. 2 refs., 7 figs

  16. Real-time probe tracking using EM-optical sensor for MRI-guided cryoablation.

    Science.gov (United States)

    Gao, Wenpeng; Jiang, Baichuan; Kacher, Daniel F; Fetics, Barry; Nevo, Erez; Lee, Thomas C; Jayender, Jagadeesan

    2018-02-01

    A method of real-time, accurate probe tracking at the entrance of the MRI bore is developed, which, fused with pre-procedural MR images, will enable clinicians to perform cryoablation efficiently in a large workspace with image guidance. Electromagnetic (EM) tracking coupled with optical tracking is used to track the probe. EM tracking is achieved with an MRI-safe EM sensor working under the scanner's magnetic field to compensate the line-of-sight issue of optical tracking. Unscented Kalman filter-based probe tracking is developed to smooth the EM sensor measurements when occlusion occurs and to improve the tracking accuracy by fusing the measurements of two sensors. Experiments with a spine phantom show that the mean targeting errors using the EM sensor alone and using the proposed method are 2.21 mm and 1.80 mm, respectively. The proposed method achieves more accurate probe tracking than using an EM sensor alone at the MRI scanner entrance. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Tendon-motion tracking in an ultrasound image sequence using optical-flow-based block matching.

    Science.gov (United States)

    Chuang, Bo-I; Hsu, Jian-Han; Kuo, Li-Chieh; Jou, I-Ming; Su, Fong-Chin; Sun, Yung-Nien

    2017-04-20

    Tendon motion, which is commonly observed using ultrasound imaging, is one of the most important features used in tendinopathy diagnosis. However, speckle noise and out-of-plane issues make the tracking process difficult. Manual tracking is usually time consuming and often yields inconsistent results between users. To automatically track tendon motion in ultrasound images, we developed a new method that combines the advantages of optical flow and multi-kernel block matching. For every pair of adjacent image frames, the optical flow is computed and used to estimate the accumulated displacement. The proposed method selects the frame interval adaptively based on this displacement. Multi-kernel block matching is then computed on the two selected frames, and, to reduce tracking errors, the detailed displacements of the frames in between are interpolated based on the optical flow results. In the experiments, cadaver data were used to evaluate the tracking results. The mean absolute error was less than 0.05 mm. The proposed method also tracked the motion of tendons in vivo, which provides useful information for clinical diagnosis. The proposed method provides a new index for adaptively determining the frame interval. Compared with other methods, the proposed method yields tracking results that are significantly more accurate.

  18. Electro-optic side-chain polyimide system with large optical nonlinearity and high thermal stability

    Science.gov (United States)

    Sotoyama, Wataru; Tatsuura, Satoshi; Yoshimura, Tetsuzo

    1994-04-01

    We report electro-optic (EO) efficiency and thermal stability of a poled polyimide system with nonlinear optical dyes as side chains. The side-chain polyimide system is synthesized from a dianhydride containing azobenzene dye and a diamine. The dye in the polymer is chemically stable for temperatures below 250 °C. The polymer can be poled simultaneously with or after imidization of the polyamic acid. Our sample poled after imidization shows a large EO coefficient (r33=10.8 pm/V at λ=1.3 μm) and long-term thermal stability at 120 °C.

  19. Optic flow stabilizes flight in ruby-throated hummingbirds.

    Science.gov (United States)

    Ros, Ivo G; Biewener, Andrew A

    2016-08-15

    Flying birds rely on visual cues for retinal image stabilization by negating rotation-induced optic flow, the motion of the visual panorama across the retina, through corrective eye and head movements. In combination with vestibular and proprioceptive feedback, birds may also use visual cues to stabilize their body during flight. Here, we test whether artificially induced wide-field motion generated through projected visual patterns elicits maneuvers in body orientation and flight position, in addition to stabilizing vision. To test this hypothesis, we present hummingbirds flying freely within a 1.2 m cylindrical visual arena with a virtual surround rotated at different speeds about its vertical axis. The birds responded robustly to these visual perturbations by rotating their heads and bodies with the moving visual surround, and by adjusting their flight trajectories, following the surround. Thus, similar to insects, hummingbirds appear to use optic flow cues to control flight maneuvers as well as to stabilize their visual inputs. © 2016. Published by The Company of Biologists Ltd.

  20. Optomechanical stability design of space optical mapping camera

    Science.gov (United States)

    Li, Fuqiang; Cai, Weijun; Zhang, Fengqin; Li, Na; Fan, Junjie

    2018-01-01

    According to the interior orientation elements and imaging quality requirements of mapping application to mapping camera and combined with off-axis three-mirror anastigmat(TMA) system, high optomechanical stability design of a space optical mapping camera is introduced in this paper. The configuration is a coaxial TMA system used in off-axis situation. Firstly, the overall optical arrangement is described., and an overview of the optomechanical packaging is provided. Zerodurglass, carbon fiber composite and carbon-fiber reinforced silicon carbon (C/SiC) are widely used in the optomechanical structure, because their low coefficient of thermal expansion (CTE) can reduce the thermal sensitivity of the mirrors and focal plane. Flexible and unloading support are used in reflector and camera supporting structure. Epoxy structural adhesives is used for bonding optics to metal structure is also introduced in this paper. The primary mirror is mounted by means of three-point ball joint flexures system, which is attach to the back of the mirror. Then, In order to predict flexural displacements due to gravity, static finite element analysis (FEA) is performed on the primary mirror. The optical performance peak-to-valley (PV) and root-mean-square (RMS) wavefront errors are detected before and after assemble. Also, the dynamic finite element analysis(FEA) of the whole optical arrangement is carried out as to investigate the performance of optomechanical. Finally, in order to evaluate the stability of the design, the thermal vacuum test and vibration test are carried out and the Modulation Transfer Function (MTF) and elements of interior orientation are presented as the evaluation index. Before and after the thermal vacuum test and vibration test, the MTF, focal distance and position of the principal point of optical system are measured and the result is as expected.

  1. Programmable current source for diode lasers stabilized optical fiber

    International Nuclear Information System (INIS)

    Gomez, J.; Camas, J.; Garcia, L.

    2012-01-01

    In this paper, we present the electronic design of a programmable stabilized current source. User can access to the source through a password, which, it has a database with the current and voltage operating points. This source was successfully used as current source in laser diode in optical fiber sensors. Variations in the laser current were carried out by a monitoring system and a control of the Direct Current (DC), which flowing through a How land source with amplifier. The laser current can be stabilized with an error percent of ± 1 μA from the threshold current (Ith) to its maximum operation current (Imax) in DC mode. The proposed design is reliable, cheap, and its output signal of stabilized current has high quality. (Author)

  2. Simple example of track finding by Fourier transform and possibilities for vector or optical processors

    International Nuclear Information System (INIS)

    Underwood, D.

    1986-01-01

    Simple examples of finding tracks by Fourier transform with filter or correlation function are presented. Possibilities for using this method in more complicated real situations and the processing times which might be achieved are discussed. The method imitates the simplest examples in the literature on optical pattern recognition and optical processing. The possible benefits of the method are in speed of processing in the optical Fourier transform wherein an entire picture is processed simultaneously. The speed of a computer vector processor may be competitive with present electro-optical devices. 2 refs., 6 figs

  3. Optical performance of inclined south-north axis three-positions tracked solar panels

    International Nuclear Information System (INIS)

    Zhong, Hao; Li, Guihua; Tang, Runsheng; Dong, Wenli

    2011-01-01

    In this work, the optical performance of solar panels with a new sun-tracking technique was theoretically investigated based on the proposed mathematical method and monthly horizontal radiation. The mechanism of the investigated sun-tracking is that the attitude angle of solar panels is daily adjusted three times at three fixed positions: eastward, southward, and westward in the morning, noon, and afternoon, respectively, by rotating solar panels about the inclined south-north axis (ISNA-3P sun-tracking). Calculation results showed that, for ISNA-3P tracked solar panels with a yearly fixed tilt-angle of the ISNA, the maximum annual collectible radiation on ISNA-3P tracked solar panels was about 93% of that on a solar panel with 2-axis sun-tracking; whereas for those with the ISNA being yearly adjusted four times at three fixed tilt-angles, it was about 96%. Results also indicated that the attempt to further increase the annual solar gain on ISNA-3P tracked solar panels by seasonally optimizing design of the sun-tracking system for maximizing solar gain in each of four seasons was not efficient, and thus not advisable in practical applications. Optimal parametric designs of such sun-tracking system for maximizing the annual solar gain on solar panels in different cases were also presented. -- Research highlights: → The paper presented a new sun-tracking technique (ISNA-3P) for possible applications in PV generating systems. → Algorithms to estimate daily collectible radiation on the fixed, 2-axis and ISNA-3P tracked solar panels were proposed based on solar geometry and monthly horizontal radiation. → A detailed theoretical study on the optical performance of such tracked solar panels in terms of R 3P-0 and R 3P-2 , the ratios of maximum annual solar gain to that on fixed and 2-axis tracked solar panels; optimal parameters affecting the optical performance of the systems were presented in the different cases. → Results showed that such sun-tracking system

  4. Theoretical model and experimental verification on the PID tracking method using liquid crystal optical phased array

    Science.gov (United States)

    Wang, Xiangru; Xu, Jianhua; Huang, Ziqiang; Wu, Liang; Zhang, Tianyi; Wu, Shuanghong; Qiu, Qi

    2017-02-01

    Liquid crystal optical phased array (LC-OPA) has been considered with great potential on the non-mechanical laser deflector because it is fabricated using photolithographic patterning technology which has been well advanced by the electronics and display industry. As a vital application of LC-OPA, free space laser communication has demonstrated its merits on communication bandwidth. Before data communication, ATP (acquisition, tracking and pointing) process costs relatively long time to result in a bottle-neck of free space laser communication. Meanwhile, dynamic real time accurate tracking is sensitive to keep a stable communication link. The electro-optic medium liquid crystal with low driving voltage can be used as the laser beam deflector. This paper presents a fast-track method using liquid crystal optical phased array as the beam deflector, CCD as a beacon light detector. PID (Proportion Integration Differentiation) loop algorithm is introduced as the controlling algorithm to generate the corresponding steering angle. To achieve the goal of fast and accurate tracking, theoretical analysis and experimental verification are demonstrated that PID closed-loop system can suppress the attitude random vibration. Meanwhile, theoretical analysis shows that tracking accuracy can be less than 6.5μrad, with a relative agreement with experimental results which is obtained after 10 adjustments that the tracking accuracy is less than12.6μrad.

  5. An embedded optical tracking system for motion-corrected magnetic resonance imaging at 7T.

    Science.gov (United States)

    Schulz, Jessica; Siegert, Thomas; Reimer, Enrico; Labadie, Christian; Maclaren, Julian; Herbst, Michael; Zaitsev, Maxim; Turner, Robert

    2012-12-01

    Prospective motion correction using data from optical tracking systems has been previously shown to reduce motion artifacts in MR imaging of the head. We evaluate a novel optical embedded tracking system. The home-built optical embedded tracking system performs image processing within a 7 T scanner bore, enabling high speed tracking. Corrected and uncorrected in vivo MR volumes are acquired interleaved using a modified 3D FLASH sequence, and their image quality is assessed and compared. The latency between motion and correction of the slice position was measured to be (19 ± 5) ms, and the tracking noise has a standard deviation no greater than 10 μm/0.005° during conventional MR scanning. Prospective motion correction improved the edge strength by 16 % on average, even though the volunteers were asked to remain motionless during the acquisitions. Using a novel method for validating the effectiveness of in vivo prospective motion correction, we have demonstrated that prospective motion correction using motion data from the embedded tracking system considerably improved image quality.

  6. Comparison of SEM and Optical Analysis of DT Neutron Tracks in CR-39 Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Mosier-Boss, P A; Carbonelle, P; Morey, M S; Tinsley, J R; Hurley, J P

    2012-01-01

    CR-39 detectors were exposed to DT neutrons generated by a Thermo Fisher model A290 neutron generator. Afterwards, the etched tracks were examined both optically and by SEM. The purpose of the analysis was to compare the two techniques and to determine whether additional information on track geometry could be obtained by SEM analysis. The use of these techniques to examine triple tracks, diagnostic of ≥9.6 MeV neutrons, observed in CR-39 used in Pd/D codeposition experiments will also be discussed.

  7. Optical fiber reach extended FMCW radar for remote respiratory tracking

    DEFF Research Database (Denmark)

    Suhr, Lau Frejstrup; Tafur Monroy, Idelfonso; Vegas Olmos, Juan José

    2017-01-01

    Wireless monitoring of human vital signs such as breathing rate is a nonintrusive alternative to contemporary solutions relying on physical contact. To ease the installment, fiber optical transmission is used to extend the reach from the transmitter and receiver circuitry to the antenna subsystem....... In this paper, a frequency modulated carrier wave radar, operating at 25.7–26.6 GHz and utilizing optical fiber extension, was experimentally demonstrated to accurately recover the breathing rate of a human placed 1 m away from the radar antennas....

  8. Optical performance of vertical axis three azimuth angles tracked solar panels

    International Nuclear Information System (INIS)

    Ma, Yi; Li, Guihua; Tang, Runsheng

    2011-01-01

    In this work, a new sun-tracking concept was proposed, and the optical performance of solar panels with such sun-tracking system was theoretically investigated based on the developed mathematical method and monthly horizontal radiation. The mechanism of the proposed sun-tracking technique is that the azimuth angle of solar panels is daily adjusted three times at three fixed positions: eastward, southward and westward in the morning, noon, and afternoon, respectively, by rotating solar panels about the vertical axis (3A sun-tracking, in short). The analysis indicated that the tilt-angle of solar panels, β 3A , azimuth angle of solar panels in the morning and afternoon from due south, φ a , and solar hour angle when the azimuth angle adjustment was made in the morning and afternoon, ω a , were three key parameters affecting the optical performance of such tracked solar panels. Calculation results showed that, for 3A tracked solar panels with a yearly fixed tilt-angle, the maximum annual collectible radiation was above 92% of that on a solar panel with full 2-axis sun-tracking; whereas for those with the tilt-angle being seasonally adjusted, it was above 95%. Results also showed that yearly or seasonally optimal values of β 3A , φ a and ω a for maximizing annual solar gain were related to site latitudes, and empirical correlations for a quick estimation of optimal values of these parameters were proposed based on climatic data of 32 sites in China.

  9. Modeling and simulation of adaptive multimodal optical sensors for target tracking in the visible to near infrared

    Science.gov (United States)

    Presnar, Michael D.

    spectrometer channel. All optical and detector sensor effects were radiometrically modeled using MATLAB and optical lens design software. Orthorectification of all sensor outputs yields multimodal pseudonadir observation video at a fixed ground sampled distance across an area of responsibility. A proprietary MATLAB-based target tracker accomplishes change detection between sequential panchromatic or DoLP observation frames, and queries the sensor for hyperspectral pixels to aid in track initialization and maintenance. Image quality, spectral quality, and tracking performance metrics are reported for varying scenario parameters including target occlusions within the scene, declination angle and jitter of the aerial platform, micropolarizer diattenuation, and spectral/spatial resolution of the adaptive sensor outputs. DoLP observations were found to track moving vehicles better than panchromatic observations at high oblique angles when facing the sensor generally toward the sun. Vehicular occlusions due to tree canopies and parallax effects of tall buildings significantly reduced tracking performance as expected. Smaller MOEMS pixel sizes drastically improved track performance, but also generated a significant number of false tracks. Atmospheric haze from urban aerosols eliminated the tracking utility of DoLP observations, while aerial platform jitter without image stabilization eliminated tracking utility in both modalities. Wire-grid micropolarizers with very low VNIR diattenuation were found to still extinguish enough cross-polarized light to successfully distinguish and track moving vehicles from their urban background. Thus, state-of-the-art lithographic techniques to create finer wire-grid spacings that exhibit high VNIR diattenuation may not be required.

  10. Tracking performance and global stability guaranteed neural control of uncertain hypersonic flight vehicle

    Directory of Open Access Journals (Sweden)

    Tao Teng

    2016-02-01

    Full Text Available In this article, a global adaptive neural dynamic surface control with predefined tracking performance is developed for a class of hypersonic flight vehicles, whose accurate dynamics is hard to obtain. The control scheme developed in this paper overcomes the limitations of neural approximation region by employing a switching mechanism which incorporates an additional robust controller outside the neural approximation region to pull the transient state variables back when they overstep the neural approximation region, such that globally uniformly ultimately bounded stability can be guaranteed. Especially, the developed global adaptive neural control also improves the tracking performance by introducing an error transformation mechanism, such that both transient and steady-state performance can be shaped according to the predefined bounds. Simulation studies on the hypersonic flight vehicle validate that the designed controller has good velocity modulation and velocity stability performance.

  11. Automated target recognition and tracking using an optical pattern recognition neural network

    Science.gov (United States)

    Chao, Tien-Hsin

    1991-01-01

    The on-going development of an automatic target recognition and tracking system at the Jet Propulsion Laboratory is presented. This system is an optical pattern recognition neural network (OPRNN) that is an integration of an innovative optical parallel processor and a feature extraction based neural net training algorithm. The parallel optical processor provides high speed and vast parallelism as well as full shift invariance. The neural network algorithm enables simultaneous discrimination of multiple noisy targets in spite of their scales, rotations, perspectives, and various deformations. This fully developed OPRNN system can be effectively utilized for the automated spacecraft recognition and tracking that will lead to success in the Automated Rendezvous and Capture (AR&C) of the unmanned Cargo Transfer Vehicle (CTV). One of the most powerful optical parallel processors for automatic target recognition is the multichannel correlator. With the inherent advantages of parallel processing capability and shift invariance, multiple objects can be simultaneously recognized and tracked using this multichannel correlator. This target tracking capability can be greatly enhanced by utilizing a powerful feature extraction based neural network training algorithm such as the neocognitron. The OPRNN, currently under investigation at JPL, is constructed with an optical multichannel correlator where holographic filters have been prepared using the neocognitron training algorithm. The computation speed of the neocognitron-type OPRNN is up to 10(exp 14) analog connections/sec that enabling the OPRNN to outperform its state-of-the-art electronics counterpart by at least two orders of magnitude.

  12. Fiber-optic delay-line stabilization of heterodyne optical signal generator and method using same

    Science.gov (United States)

    Logan, Ronald T. (Inventor)

    1997-01-01

    The present invention is a laser heterodyne frequency generator system with a stabilizer for use in the microwave and millimeter-wave frequency ranges utilizing a photonic mixer as a photonic phase detector in a stable optical fiber delay-line. Phase and frequency fluctuations of the heterodyne laser signal generators are stabilized at microwave and millimeter wave frequencies by a delay line system operating as a frequency discriminator. The present invention is free from amplifier and mixer 1/.function. noise at microwave and millimeter-wave frequencies that typically limit phase noise performance in electronic cavity stabilized electronic oscillators. Thus, 1/.function. noise due to conventional mixers is eliminated and stable optical heterodyne generation of electrical signals is achieved.

  13. A novel optical investigation technique for railroad track inspection and assessment

    Science.gov (United States)

    Sabato, Alessandro; Beale, Christopher H.; Niezrecki, Christopher

    2017-04-01

    Track failures due to cross tie degradation or loss in ballast support may result in a number of problems ranging from simple service interruptions to derailments. Structural Health Monitoring (SHM) of railway track is important for safety reasons and to reduce downtime and maintenance costs. For this reason, novel and cost-effective track inspection technologies for assessing tracks' health are currently insufficient and needed. Advancements achieved in recent years in cameras technology, optical sensors, and image-processing algorithms have made machine vision, Structure from Motion (SfM), and three-dimensional (3D) Digital Image Correlation (DIC) systems extremely appealing techniques for extracting structural deformations and geometry profiles. Therefore, optically based, non-contact measurement techniques may be used for assessing surface defects, rail and tie deflection profiles, and ballast condition. In this study, the design of two camera-based measurement systems is proposed for crossties-ballast condition assessment and track examination purposes. The first one consists of four pairs of cameras installed on the underside of a rail car to detect the induced deformation and displacement on the whole length of the track's cross tie using 3D DIC measurement techniques. The second consists of another set of cameras using SfM techniques for obtaining a 3D rendering of the infrastructure from a series of two-dimensional (2D) images to evaluate the state of the track qualitatively. The feasibility of the proposed optical systems is evaluated through extensive laboratory tests, demonstrating their ability to measure parameters of interest (e.g. crosstie's full-field displacement, vertical deflection, shape, etc.) for assessment and SHM of railroad track.

  14. Flat Optical Fiber Daylighting System with Lateral Displacement Sun-Tracking Mechanism for Indoor Lighting

    Directory of Open Access Journals (Sweden)

    Ngoc Hai Vu

    2017-10-01

    Full Text Available An essential impact which can improve the indoor environment and save on power consumption for artificial lighting is utilization of daylight. Optical fiber daylighting technology offers a way to use direct daylight for remote spaces in a building. However, the existing paradigm based on the precise orientation of sunlight concentrator toward the Sun is very costly and difficult to install on the roof of buildings. Here, we explore an alternative approach using mirror-coated lens array and planar waveguide to develop a flat optical fiber daylighting system (optical fiber daylighting panel with lateral displacement Sun-tracking mechanism. Sunlight collected and reflected by each mirror-coated lens in a rectangular lens array is coupled into a planar waveguide using cone prisms placed at each lens focus. This geometry yields a thin, flat profile for Sunlight concentrator. Our proposed concentrating panel can be achieved with 35 mm thickness while the concentrator’s width and length are 500 mm × 500 mm. The commercial optical simulation tool (LightToolsTM was used to develop the simulation models and analyze the system performance. Simulation results based on the designed system demonstrated an optical efficiency of 51.4% at a concentration ratio of 125. The system can support utilizing a lateral displacement Sun-tracking system, which allows for replacing bulky and robust conventional rotational Sun-tracking systems. This study shows a feasibility of a compact and inexpensive optical fiber daylighting system to be installed on the roof of buildings.

  15. Optical performance of inclined south-north single-axis tracked solar panels

    International Nuclear Information System (INIS)

    Li, Zhimin; Liu, Xinyue; Tang, Runsheng

    2010-01-01

    To investigate optical performance of the inclined south-north single-axis (ISN-axis, in short) tracked solar panels, a mathematical procedure to estimate the annual collectible radiation on fixed and tracked panels was suggested based on solar geometry and monthly horizontal radiation. For solar panels tracking about ISN-axis, the yearly optimal tilt-angle of ISN-axis for maximizing annual solar gain was about 3 o deviating from the site latitude in most of China except in areas with poor solar resources, and the maximum annual collectible radiation on ISN-axis tracked panels was about 97-98% of that on dual-axis tracked panels; whereas for ISN-axis tracked panels with the tilt-angle of ISN-axis being adjusted four times in a year at three fixed tilt-angles, the annual collectible radiation was almost close to that on dual-axis tracked panels, the optimum date of tilt-angle adjustment of ISN-axis was 23 days from the equinoxes, and the optimum tilt-angle adjustment value for each adjustment was about 22 o . Compared to fixed south-facing solar panels inclined at an optimal tilt-angle, the increase in the annual solar gain due to using ISN-axis sun tracking was above 30% in the areas with abundant solar resources and less than 20% in the areas with poor solar resources.

  16. Survey of energy efficient tracking and localization techniques in buildings using optical and wireless communication media

    NARCIS (Netherlands)

    Bruintjes, Tom M.; Kokkeler, Andre B.J.; Karagiannis, Georgios; Smit, Gerard J. M.; Bellalta, Boris; Vinel, Alexey; Jonsson, Magnus; Barcelo, Jaume; Maslennikov, Roman; Chatzimisios, Periklis; Malone, David

    2012-01-01

    This paper presents a survey of beamforming, beamsteering and mobile tracking techniques. The survey was made in the context of the SOWICI project. The aim of this project is to reduce power consumption of data exchanging devices within houses. An optical fiber network is used for data transport to

  17. An automatic analyzer of solid state nuclear track detectors using an optic RAM as image sensor

    International Nuclear Information System (INIS)

    Staderini, E.M.; Castellano, A.

    1986-01-01

    An optic RAM is a conventional digital random access read/write dynamic memory device featuring a quartz windowed package and memory cells regularly ordered on the chip. Such a device is used as an image sensor because each cell retains data stored in it for a time depending on the intensity of the light incident on the cell itself. The authors have developed a system which uses an optic RAM to acquire and digitize images from electrochemically etched CR39 solid state nuclear track detectors (SSNTD) in the track count rate up to 5000 cm -2 . On the digital image so obtained, a microprocessor, with appropriate software, performs image analysis, filtering, tracks counting and evaluation. (orig.)

  18. Effective star tracking method based on optical flow analysis for star trackers.

    Science.gov (United States)

    Sun, Ting; Xing, Fei; Wang, Xiaochu; Li, Jin; Wei, Minsong; You, Zheng

    2016-12-20

    Benefiting from rapid development of imaging sensor technology, modern optical technology, and a high-speed computing chip, the star tracker's accuracy, dynamic performance, and update rate have been greatly improved with low power consumption and miniature size. The star tracker is currently one of the most competitive attitude measurement sensors. However, due to restrictions of the optical imaging system, difficulties still exist in moving star spot detection and star tracking when in special motion conditions. An effective star tracking method based on optical flow analysis for star trackers is proposed in this paper. Spot-based optical flow, based on a gray gradient between two adjacent star images, is analyzed to distinguish the star spot region and obtain an accurate star spot position so that the star tracking can keep continuous under high dynamic conditions. The obtained star vectors and extended Kalman filter (EKF) are then combined to conduct an angular velocity estimation to ensure region prediction of the star spot; this can be combined with the optical flow analysis result. Experiment results show that the method proposed in this paper has advantages in conditions of large angular velocity and large angular acceleration, despite the presence of noise. Higher functional density and better performance can be achieved; thus, the star tracker can be more widely applied in small satellites, remote sensing, and other complex space missions.

  19. POAC (programmable optical array computer) applied for target recognition and tracking

    Science.gov (United States)

    Tokes, Szabolcs; Orzo, Laszlo; Ayoub, Ahmed E.; Roska, Tamas

    2004-12-01

    A portable programmable opto-electronic analogic CNN computer (Laptop-POAC) has been built and used to recognize and track targets. Its kernel processor is a novel type of high performance optical correlator based on the use of bacteriorhodopsin (BR) as a dynamic holographic material. This optical CNN implementation combines the optical computer's high speed, high parallelism (~106 channel) and large applicable template sizes with flexible programmability of the CNN devices. Unique feature of this optical array computer is that programming templates can be applied either by a 2D acousto-optical deflector (up to 64x64 pixel size templates) incoherently or by an LCD-SLM (up to 128x128 size templates) coherently. So it can work both in totally coherent and partially incoherent way, utilizing the actual advantages of the used mode of operation. Input images are fed-in by a second LCD-SLM of 600x800 pixel resolution. Evaluation of trade-off between speed and resolution is given. Novel and effective target recognition and multiple-target-tracking algorithms have been developed for the POAC. Tracking experiments are demonstrated. Collision avoidance experiments are being conducted. In the present model a CCD camera is recording the correlograms, however, later a CNN-UM chip and a high-speed CMOS camera will be applied for post-processing.

  20. Integrating optical finger motion tracking with surface touch events

    Science.gov (United States)

    MacRitchie, Jennifer; McPherson, Andrew P.

    2015-01-01

    This paper presents a method of integrating two contrasting sensor systems for studying human interaction with a mechanical system, using piano performance as the case study. Piano technique requires both precise small-scale motion of fingers on the key surfaces and planned large-scale movement of the hands and arms. Where studies of performance often focus on one of these scales in isolation, this paper investigates the relationship between them. Two sensor systems were installed on an acoustic grand piano: a monocular high-speed camera tracking the position of painted markers on the hands, and capacitive touch sensors attach to the key surfaces which measure the location of finger-key contacts. This paper highlights a method of fusing the data from these systems, including temporal and spatial alignment, segmentation into notes and automatic fingering annotation. Three case studies demonstrate the utility of the multi-sensor data: analysis of finger flexion or extension based on touch and camera marker location, timing analysis of finger-key contact preceding and following key presses, and characterization of individual finger movements in the transitions between successive key presses. Piano performance is the focus of this paper, but the sensor method could equally apply to other fine motor control scenarios, with applications to human-computer interaction. PMID:26082732

  1. Integrating optical finger motion tracking with surface touch events

    Directory of Open Access Journals (Sweden)

    Jennifer eMacRitchie

    2015-06-01

    Full Text Available This paper presents a method of integrating two contrasting sensor systems for studying human interaction with a mechanical system, using piano performance as the case study. Piano technique requires both precise small-scale motion of fingers on the key surfaces and planned large-scale movement of the hands and arms. Where studies of performance often focus on one of these scales in isolation, this paper investigates the relationship between them. Two sensor systems were installed on an acoustic grand piano: a monocular high-speed camera tracking the position of painted markers on the hands, and capacitive touch sensors attach to the key surfaces which measure the location of finger-key contacts. This paper highlights a method of fusing the data from these systems, including temporal and spatial alignment, segmentation into notes and automatic fingering annotation. Three case studies demonstrate the utility of the multi-sensor data: analysis of finger flexion or extension based on touch and camera marker location, timing analysis of finger-key contact preceding and following key presses, and characterisation of individual finger movements in the transitions between successive key presses. Piano performance is the focus of this paper, but the sensor method could equally apply to other fine motor control scenarios, with applications to human-computer interaction.

  2. Optical and tribomechanical stability of optically variable interference security devices prepared by dual ion beam sputtering.

    Science.gov (United States)

    Çetinörgü-Goldenberg, Eda; Baloukas, Bill; Zabeida, Oleg; Klemberg-Sapieha, Jolanta; Martinu, Ludvik

    2011-07-01

    Optical security devices applied to banknotes and other documents are exposed to different types of harsh environments involving the cycling of temperature, humidity, chemical agents, and tribomechanical intrusion. In the present work, we study the stability of optically variable devices, namely metameric interference filters, prepared by dual ion beam sputtering onto polycarbonate and glass substrates. Specifically, we assess the color difference as well as the changes in the mechanical properties and integrity of all-dielectric and metal-dielectric systems due to exposure to bleach, detergent and acetone agents, and heat and humidity. The results underline a significant role of the substrate material, of the interfaces, and of the nature and microstructure of the deposited films in long term stability under everyday application conditions.

  3. Real-time optical multiple-object recognition and tracking demonstration: A friendly challenge to the digital field

    Science.gov (United States)

    Chao, Tien-Hsin; Liu, Hua-Kuang

    1980-01-01

    Researchers demonstrated the first optical multiple object tracking system. The system is capable of simultaneous tracking of multiple objects, each with independent movements in real-time, limited only to the TV frame rate (30 msec). In order to perform a similar tracking operation, a large computer system and very complex software would be needed. Although researchers have demonstrated the tracking of only 3 objects, the system capacity can easily be expanded by 2 orders of magnitude.

  4. Instrumentation by accelerometers and distributed optical fiber sensors of a real ballastless track structure

    Science.gov (United States)

    Chapeleau, Xavier; Cottineau, Louis-Marie; Sedran, Thierry; Cailliau, Joël; Gueguen, Ivan; Dumoulin, Jean

    2015-04-01

    nano computer (called Pegase and developed at Ifsttar for data acquisition [3]) were performed automatically every time that a threshold is exceeded due to the passage of a train. These data are then send to a web server via a 3G Wireless Network. Many data was thus stored daily for several months. Moreover, several thermocouples were embedded at different depths in order to measure thermal gradients into the track slab. From the accelerometers signals, the deflection of the track slab are then obtained and compared to the measurements of thermal gradients. This comparison show clearly the daily evolution of the curvature with the thermal gradient changes as estimated by the simulation. This result was confirmed indirectly by strain profile measurements obtained by the Rayleigh fiber optic sensing technique. Two fiber optics embedded in the upper and lower part of the foundation slab show that contact conditions between the foundation slab and the track slab change with thermal gradient. 1 - X. Chapeleau, T. Sedran, L.-M. Cottineau, J. Cailliau, F. Taillade, I. Gueguen, J.-M. Henault. Study of ballastless track structure monitoring by distributed optical fiber sensors on a real-scale mockup in laboratory. Engineering Structures, 2013, 56, pp. 1751-1757. 2 - X. Chapeleau, L.-M. Cottineau, T. Sedran, J. Cailliau, I. Gueguen. Instrumentation by distributed optical fiber sensors of a new ballastless track structure. EGU General Assembly 2013, held 7-12 April, 2013 in Vienna, Austria, id. EGU2013-8946 3 - V. Le Cam, L. Lemarchand, L-M. Cottineau and F. Bourquin. Design of a generic smart and wireless sensors network - benefits of emerging technologies. Structural Health Monitoring 2008, 1(1), pp. 598-605.

  5. Mechanical Stability Study for Integrable Optics Test Accelerator at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    McGee, Mike [Fermilab; Andrews, Richard [Fermilab; Carlson, Kermit [Fermilab; Leibfritz, Jerry [Fermilab; Nobrega, Lucy [Fermilab; Valishev, Alexander [Fermilab

    2016-07-01

    The Integrable Optics Test Accelerator (IOTA) is proposed for operation at Fermilab. The goal of IOTA is to create practical nonlinear accelerator focusing systems with a large frequency spread and stable particle motion. The IOTA is a 40 m circumference, 150 MeV (e-), 2.5 MeV (p⁺) diagnostic test ring. A heavy low frequency steel floor girder is proposed as the primary tier for IOTA device component support. Two design lengths; (8) 4 m and (2) 2.8 m long girders with identical cross section completely encompass the ring. This study focuses on the 4 m length girder and the development of a working prototype. Hydrostatic Level Sensor (HLS), temperature, metrology and fast motion measurements characterize the anticipated mechanical stability of the IOTA ring.

  6. Wave-guided Optical Waveguides tracked and coupled using dynamic diffractive optics

    DEFF Research Database (Denmark)

    Glückstad, Jesper; Villangca, Mark Jayson; Bañas, Andrew Rafael

    With light’s miniscule momentum, shrinking robotics down to the micro- and nano-scale regime creates opportunities for exploiting optical forces and near-field light delivery in advanced actuation and control atthe smallest physical dimensions. Advancing light-driven nano- or micro......-actuation requires the optimization of optical forces and optical torques that, in turn, requires the optimization of the underlying light-matter interaction [1]. We have previously proposed and demonstrated micro-targeted light-delivery and the opto-mechanical capabilities of so-called wave-guided optical...

  7. Cancer cell imaging by stable wet near-field scanning optical microscope with resonance tracking method

    International Nuclear Information System (INIS)

    Park, Kyoung-Duck; Park, Doo-Jae; Jeong, Mun-Seok; Choi, Geun-Chang; Lee, Seung-Gol; Byeon, Clare-Chisu; Choi, Soo-Bong

    2014-01-01

    We report on a successful topographical and optical imaging of various cancer cells in liquid and in air by using a stable wet near-field scanning optical microscope that utilizes a resonance tracking method. We observed a clear dehydration which gives rise to a decrease in the cell volume down to 51%. In addition, a micro-ball lens effect due to the round-shaped young cancer cells was observed from near-field imaging, where the refractive index of young cancer cells was deduced.

  8. Cancer cell imaging by stable wet near-field scanning optical microscope with resonance tracking method

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyoung-Duck [Sungkyunkwan University, Suwon (Korea, Republic of); Inha University, Incheon (Korea, Republic of); Park, Doo-Jae; Jeong, Mun-Seok [Sungkyunkwan University, Suwon (Korea, Republic of); Choi, Geun-Chang [Seoul National University, Seoul (Korea, Republic of); Lee, Seung-Gol [Inha University, Incheon (Korea, Republic of); Byeon, Clare-Chisu [Kyungpook National University, Daegu (Korea, Republic of); Choi, Soo-Bong [Incheon National University, Incheon (Korea, Republic of)

    2014-05-15

    We report on a successful topographical and optical imaging of various cancer cells in liquid and in air by using a stable wet near-field scanning optical microscope that utilizes a resonance tracking method. We observed a clear dehydration which gives rise to a decrease in the cell volume down to 51%. In addition, a micro-ball lens effect due to the round-shaped young cancer cells was observed from near-field imaging, where the refractive index of young cancer cells was deduced.

  9. A fully automated optical microscope for analysis of particle tracks in solids

    CERN Document Server

    Dolleiser, M

    2002-01-01

    A fully automatic optical microscope (FAOM) for on-line analysis of micro-objects is described. The system has many capabilities, such as autofocusing, autocounting, autoscanning, producing optical images corresponding to different depths in the sample, contour and edge finding, etc. The autofocusing can be achieved with more than one method. The system can be used for analysis and counting (high- density) micro-objects, such as particle tracks in plastic detectors. The processing speed of the system is adequate and it can be used in analysis of macro samples. The software of the FAOM is written in C++ and runs under Microsoft Windows operating systems. (8 refs).

  10. LISA telescope assembly optical stability characterization for ESA

    Science.gov (United States)

    Verlaan, A. L.; Hogenhuis, H.; Pijnenburg, J.; Lemmen, M.; Lucarelli, S.; Scheulen, D.; Ende, David

    2017-11-01

    The LISA Optical Stability Characterization project is part of the LISA CTP activities to achieve the required Technology Readiness Level (TRL) for all of the LISA technologies used. This activity aims demonstration of the Telescope Assembly (TA), with a structure based on CFRP technology, that a CTE of 10-7 1/K can be achieved with measures to tune the CTE to this level. In addition the demonstration is required to prove that the structure exhibits highly predictable mechanical distortion characteristics when cooling down to - 90°C, during outgassing in space and when going from 1g environment to 0g. This paper describes the test facilities as well as the first test results. A dedicated test setup is designed and realized to allow monitoring dimensional variations of the TA using three interferometers, while varying the temperature in a thermal vacuum chamber. Critical parameters of the verification setup are the length metrology accuracy in thermal vacuum and the thermal vacuum flexibility and stability. The test programme includes Telescope Assembly CTE measurements and thermal gradient characterization.

  11. Enhanced Algorithms for EO/IR Electronic Stabilization, Clutter Suppression, and Track-Before-Detect for Multiple Low Observable Targets

    Science.gov (United States)

    Tartakovsky, A.; Brown, A.; Brown, J.

    The paper describes the development and evaluation of a suite of advanced algorithms which provide significantly-improved capabilities for finding, fixing, and tracking multiple ballistic and flying low observable objects in highly stressing cluttered environments. The algorithms have been developed for use in satellite-based staring and scanning optical surveillance suites for applications including theatre and intercontinental ballistic missile early warning, trajectory prediction, and multi-sensor track handoff for midcourse discrimination and intercept. The functions performed by the algorithms include electronic sensor motion compensation providing sub-pixel stabilization (to 1/100 of a pixel), as well as advanced temporal-spatial clutter estimation and suppression to below sensor noise levels, followed by statistical background modeling and Bayesian multiple-target track-before-detect filtering. The multiple-target tracking is performed in physical world coordinates to allow for multi-sensor fusion, trajectory prediction, and intercept. Output of detected object cues and data visualization are also provided. The algorithms are designed to handle a wide variety of real-world challenges. Imaged scenes may be highly complex and infinitely varied -- the scene background may contain significant celestial, earth limb, or terrestrial clutter. For example, when viewing combined earth limb and terrestrial scenes, a combination of stationary and non-stationary clutter may be present, including cloud formations, varying atmospheric transmittance and reflectance of sunlight and other celestial light sources, aurora, glint off sea surfaces, and varied natural and man-made terrain features. The targets of interest may also appear to be dim, relative to the scene background, rendering much of the existing deployed software useless for optical target detection and tracking. Additionally, it may be necessary to detect and track a large number of objects in the threat cloud

  12. Real-time optical tracking for motion compensated irradiation with scanned particle beams at CNAO

    Energy Technology Data Exchange (ETDEWEB)

    Fattori, G., E-mail: giovanni.fattori@psi.ch [Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Seregni, M. [Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Pella, A. [Centro Nazionale di Adroterapia Oncologica (CNAO), Strada Campeggi 53, 27100 Pavia (Italy); Riboldi, M. [Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Capasso, L. [Istituto Nazionale di Fisica Nucleare, Section of Torino, Torino 10125 (Italy); Donetti, M. [Centro Nazionale di Adroterapia Oncologica (CNAO), Strada Campeggi 53, 27100 Pavia (Italy); Istituto Nazionale di Fisica Nucleare, Section of Torino, Torino 10125 (Italy); Ciocca, M. [Centro Nazionale di Adroterapia Oncologica (CNAO), Strada Campeggi 53, 27100 Pavia (Italy); Giordanengo, S. [Istituto Nazionale di Fisica Nucleare, Section of Torino, Torino 10125 (Italy); Pullia, M. [Centro Nazionale di Adroterapia Oncologica (CNAO), Strada Campeggi 53, 27100 Pavia (Italy); Marchetto, F. [Istituto Nazionale di Fisica Nucleare, Section of Torino, Torino 10125 (Italy); Baroni, G. [Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Centro Nazionale di Adroterapia Oncologica (CNAO), Strada Campeggi 53, 27100 Pavia (Italy)

    2016-08-11

    Purpose: We describe the interface developed at the National Center for Oncological Hadrontherapy in Pavia to provide the dose delivery systems with real time respiratory motion information captured with an optical tracking system. An experimental study is presented to assess the technical feasibility of the implemented organ motion compensation framework, by analyzing the film response when irradiated with proton beams. Methods: The motion monitoring solution is based on a commercial hardware for motion capture running in-house developed software for respiratory signal processing. As part of the integration, the latency of data transmission to the dose delivery system was experimentally quantified and accounted for by signal time prediction. A respiratory breathing phantom is presented and used to test tumor tracking based either on the optical measurement of the target position or internal-external correlation models and beam gating, as driven by external surrogates. Beam tracking was tested considering the full target motion excursion (25×18 mm), whereas it is limited to 6×2 mm in the gating window. The different motion mitigation strategies were evaluated by comparing the experimental film responses with respect to static irradiation conditions. Dose inhomogeneity (IC) and conformity (CI) are provided as main indexes for dose quality assessment considering the irradiation in static condition as reference. Results: We measured 20.6 ms overall latency for motion signal processing. Dose measurements showed that beam tracking largely preserved dose homogeneity and conformity, showing maximal IC and CI variations limited to +0.10 and −0.01 with respect to the static reference. Gating resulted in slightly larger discrepancies (ΔIC=+0.20, ΔCI=−0.13) due to uncompensated residual motion in the gating window. Conclusions: The preliminary beam tracking and gating results verified the functionality of the prototypal solution for organ motion compensation based on

  13. Instrumentation by distributed optical fiber sensors of a new ballastless track structure

    Science.gov (United States)

    Chapeleau, Xavier; Cottineau, Louis-Marie; Sedran, Thierry; Gueguen, Ivan; Cailliau, Joël

    2013-04-01

    While relatively expensive to build, ballastless track structures are presently seen as an attractive alternative to conventional ballast. With its service life of at least 60 years, they require little maintenance and hence they offer great availability. Other reasons for using ballastless tracks instead of ballasted tracks are the lack of suitable ballast material and the need of less noise and vibration for high-speed, in particularly. A new ballastless track structure has been designed to be circulated up to 300km/h, with a target life of 100 years. It is an interoperable way on concrete slabs that are cast-in-place and slip formed. This structure has been built and tested at the scale one in our laboratory. Indeed, ten millions cyclic loads were applied at 2.5Hz to evaluate the fatigue behaviour under selected mechanical and thermal conditions. To monitor the thermo-mechanical behavior of this new structure and to verify the numerical simulations used for its design, a lot of sensors have been embedded. In particularly, we have tested an optical fiber as distributed sensors to measure strain distribution in the railway model. This sensor can also be used to detect, localize and monitor cracks in concrete slabs. The optical fiber sensing technique ("Rayleigh technique") used in this experimentation has a centimetric spatial resolution which allows to measure complex strain profiles unlike electrical strain gauges which only give local information. Firstly, optical cables used as sensors have been successfully embedded and attached to the reinforcing steel bars in the structure. We have noted that they are resistant enough to resist concrete pouring and working activities. Secondly, strains measured by conventional strain gauges has confirmed the quality of the strain profiles measurements obtained by optical fiber sensors. Moreover, we have found a good agreement between experimental profiles measurements and those obtained by numerical simulations. Early

  14. System Design and Implementation of the Virginia Tech Optical Satellite Tracking Telescope

    Science.gov (United States)

    Luciani, D.; Black, J.

    2016-09-01

    The Virginia Tech Optical Satellite Tracking Telescope (VTOST) aims to test the feasibility of a commercial off-the-shelf (COTS) designed tracking system for Space Situational Awareness (SSA) data contribution. A novel approach is considered, combining two COTS systems, a high-powered telescope, built for astronomy purposes, and a larger field of view (FOV) camera. Using only publicly available two-line element sets (TLEs), orbital propagation accuracy degrades quickly with time from epoch and is often not accurate enough to task a high-powered, small FOV telescope. Under this experimental approach, the larger FOV camera is used to acquire and track the resident space object (RSO) and provide a real-time pointing update to allow the high-powered telescope to track the RSO and provide possible resolved imagery. VTOST is designed as a remotely taskable sensor, based on current network architecture, capable of serving as a platform for further SSA studies, including unresolved and resolved imagery analysis, network tasking, and orbit determination. Initial design considerations are based on the latest Raven class and other COTS based telescope research, including research by the Air Force Research Lab (AFRL), ExoAnalytic Solutions, and other university level telescope projects. A holistic system design, including astronomy, image processing, and tracking methods, in a low-budget environment is considered. Method comparisons and results of the system design process are presented.

  15. Gas laser having an integral optical resonator with external stabilizing means

    International Nuclear Information System (INIS)

    Hensolt, R.A.; Dowley, M.W.

    1975-01-01

    A gaseous laser having an internal optical resonator is provided with external stabilizing means for maintaining alignment of mirrors forming the optical resonator. Means are also provided for allowing expansion of the remainder of the gas-confining envelope relative to the stabilized resonator mirrors during the operation of the laser. (U.S.)

  16. Online tracking and retargeting with applications to optical biopsy in gastrointestinal endoscopic examinations.

    Science.gov (United States)

    Ye, Menglong; Giannarou, Stamatia; Meining, Alexander; Yang, Guang-Zhong

    2016-05-01

    With recent advances in biophotonics, techniques such as narrow band imaging, confocal laser endomicroscopy, fluorescence spectroscopy, and optical coherence tomography, can be combined with normal white-light endoscopes to provide in vivo microscopic tissue characterisation, potentially avoiding the need for offline histological analysis. Despite the advantages of these techniques to provide online optical biopsy in situ, it is challenging for gastroenterologists to retarget the optical biopsy sites during endoscopic examinations. This is because optical biopsy does not leave any mark on the tissue. Furthermore, typical endoscopic cameras only have a limited field-of-view and the biopsy sites often enter or exit the camera view as the endoscope moves. In this paper, a framework for online tracking and retargeting is proposed based on the concept of tracking-by-detection. An online detection cascade is proposed where a random binary descriptor using Haar-like features is included as a random forest classifier. For robust retargeting, we have also proposed a RANSAC-based location verification component that incorporates shape context. The proposed detection cascade can be readily integrated with other temporal trackers. Detailed performance evaluation on in vivo gastrointestinal video sequences demonstrates the performance advantage of the proposed method over the current state-of-the-art. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. RFID-over-Fiber system for agricultural exploitations - Wireless track and trace with range extension using optical fiber

    DEFF Research Database (Denmark)

    Madsen, Peter; Suhr, Lau Frejstrup; Cavalcante, Lucas Costa Pereira

    2015-01-01

    This paper proposes and demonstrates an RFIDover-Fiber wireless track and trace system using active RFID tags and operating over distances up to 30 km of optical fiber and 35 meters of wireless readability......This paper proposes and demonstrates an RFIDover-Fiber wireless track and trace system using active RFID tags and operating over distances up to 30 km of optical fiber and 35 meters of wireless readability...

  18. Frequency tracking and stabilization of a tunable dual-wavelength external-cavity diode laser

    Science.gov (United States)

    Hsu, L.; Chi, L. C.; Wang, S. C.; Pan, Ci-Ling

    1999-09-01

    We show a unique dual-wavelength external-cavity laser diode with frequency tracking capability and obtain a stable beat frequency between the dual-wavelength output. By using a Fabry-Perot interferometer as the frequency discriminator and the time-gating technique in a servo loop, the peak-to-peak frequency fluctuations were stabilized, with respect to the Fabry-Perot cavity, to 86 kHz in the dual-wavelength output at 802.5 and 804.5 nm, and to 17 kHz in their 0.9 THz beat signal. Similar performance was achieved for tuning of the dual wavelength separation ranging from 0.2 to 4 nm.

  19. Tracking Dissipation Reduction, Externalities, Stability and Sustainability for Environmental Management of New Orleans

    Science.gov (United States)

    McNamara, D.; Werner, B. T.

    2014-12-01

    Sustainability requires stability, but in promoting economic development, modern economies and political systems reduce stabilizing dissipation by facilitating use and management of the environment through engineered mitigation of disturbances, which externalizes dissipation over the short to medium term. To quantitatively investigate the relationship between a range of environmental management approaches and sustainability, and the implications for Earth's future, we track the impact of management strategies on dissipation within the system and its externalities in a numerical model for the coupled economic, political/management and flooding dynamics of New Orleans. The model simulates river floods, hurricane storm-surge-induced floods, subsidence, and agent-based market interactions leading to development of port services, hotels, homes and labor relations. Flood protection decisions for levee construction based on the baseline case of cost-benefit analyses designed to prevent short-term economic loss from future floods qualitatively reproduce historical expansion of New Orleans and increases in levee height. Alternative management strategies explored include majority voting, consensus-based decision-making, and variations in discounting of costs and benefits. Enhanced dissipation is measured relative to optimal economic development without floods. The focus of modern economies on commodification is exploited to track dissipation as a scalar representing value or power, but this approach might not be applicable to more complicated traditional/indigenous cultures or cultures of resistance. For the baseline case, short-to-medium-term reductions in dissipation destabilize the coupled system, resulting in episodic bursts of externalized dissipation during flooding. Comparisons of results for a range of management options and generalizations of this approach for alternative cultural systems will be discussed.

  20. A Microscopic Optically Tracking Navigation System That Uses High-resolution 3D Computer Graphics.

    Science.gov (United States)

    Yoshino, Masanori; Saito, Toki; Kin, Taichi; Nakagawa, Daichi; Nakatomi, Hirofumi; Oyama, Hiroshi; Saito, Nobuhito

    2015-01-01

    Three-dimensional (3D) computer graphics (CG) are useful for preoperative planning of neurosurgical operations. However, application of 3D CG to intraoperative navigation is not widespread because existing commercial operative navigation systems do not show 3D CG in sufficient detail. We have developed a microscopic optically tracking navigation system that uses high-resolution 3D CG. This article presents the technical details of our microscopic optically tracking navigation system. Our navigation system consists of three components: the operative microscope, registration, and the image display system. An optical tracker was attached to the microscope to monitor the position and attitude of the microscope in real time; point-pair registration was used to register the operation room coordinate system, and the image coordinate system; and the image display system showed the 3D CG image in the field-of-view of the microscope. Ten neurosurgeons (seven males, two females; mean age 32.9 years) participated in an experiment to assess the accuracy of this system using a phantom model. Accuracy of our system was compared with the commercial system. The 3D CG provided by the navigation system coincided well with the operative scene under the microscope. Target registration error for our system was 2.9 ± 1.9 mm. Our navigation system provides a clear image of the operation position and the surrounding structures. Systems like this may reduce intraoperative complications.

  1. Measurement of nanoparticle size, suspension polydispersity, and stability using near-field optical trapping and light scattering (Conference Presentation)

    Science.gov (United States)

    Schein, Perry; O'Dell, Dakota; Erickson, David

    2017-02-01

    Nanoparticles are becoming ubiquitous in applications including diagnostic assays, drug delivery and therapeutics. However, there remain challenges in the quality control of these products. Here we present methods for the orthogonal measurement of these parameters by tracking the motion of the nanoparticle in all three special dimensions as it interacts with an optical waveguide. These simultaneous measurements from a single particle basis address some of the gaps left by current measurement technologies such as nanoparticle tracking analysis, ζ-potential measurements, and absorption spectroscopy. As nanoparticles suspended in a microfluidic channel interact with the evanescent field of an optical waveguide, they experience forces and resulting motion in three dimensions: along the propagation axis of the waveguide (x-direction) they are propelled by the optical forces, parallel to the plane of the waveguide and perpendicular to the optical propagation axis (y-direction) they experience an optical gradient force generated from the waveguide mode profile which confines them in a harmonic potential well, and normal to the surface of the waveguide they experience an exponential downward optical force balanced by the surface interactions that confines the particle in an asymmetric well. Building on our Nanophotonic Force Microscopy technique, in this talk we will explain how to simultaneously use the motion in the y-direction to estimate the size of the particle, the comparative velocity in the x-direction to measure the polydispersity of a particle population, and the motion in the z-direction to measure the potential energy landscape of the interaction, providing insight into the colloidal stability.

  2. Diffractive beam shaping, tracking and coupling for wave-guided optical waveguides (WOWs)

    DEFF Research Database (Denmark)

    Villangca, Mark Jayson; Bañas, Andrew Rafael; Aabo, Thomas

    2014-01-01

    We have previously proposed and demonstrated the targeted-light delivery capability of wave-guided optical waveguides (WOWs). The full strength of this structure-mediated paradigm can be harnessed by addressing multiple WOWs and manipulating them to work in tandem. We propose the use of diffractive...... techniques to create multiple focal spots that can be coupled into light manipulated WOWs. This is done by using a spatial light modulator to project the necessary phase to generate the multiple coupling light spots. We incorporate a diffractive setup in our Biophotonics Workstation (BWS) and demonstrate...... holographic shaping, tracking of light in 3D with the purpose of coupling light in the WOWs....

  3. Atmospheric-Fade-Tolerant Tracking and Pointing in Wireless Optical Communication

    Science.gov (United States)

    Ortiz, Gerardo; Lee, Shinhak

    2003-01-01

    An acquisition, tracking, and pointing (ATP) system, under development at the time of reporting the information for this article, is intended to enable a terminal in a free-space optical communication system to continue to aim its transmitting laser beam toward a receiver at a remote terminal when the laser beacon signal from the remote terminal temporarily fades or drops out of sight altogether. Such fades and dropouts can be caused by adverse atmospheric conditions (e.g., rain or clouds). They can also occur when intervening objects block the line of sight between terminals as a result of motions of those objects or of either or both terminals

  4. Modifications of the optical properties for DAM-ADC nuclear track detector exposed to alpha particles

    Science.gov (United States)

    Rammah, Y. S.; Awad, E. M.

    2018-05-01

    Modifications of the optical properties of diallyl maleate-allyl diglycol carbonate (DAM-ADC) nuclear detector induced by alpha particles are described. DAM-ADC samples were irradiated perpendicularly by thin 241Am disk source that emits alpha particles with 5.48 MeV. The optical absorption has been measured using the ultraviolet-visible (UV-1100) spectroscopy. It was found that DAM-ADC polymer shows substantial modifications in its optical characteristics upon irradiated with alpha particles with different energies. The optical energy band gap (Egap) for the detector was calculated for the direct and the indirect allowed transitions in K-space using two approaches (Tauc's model and absorption spectrum fitting (ASF) method). Urbach's energy (Ea), number of carbon atoms per conjugated length (N), number of carbon atoms per cluster (M), and refractive index (n) for the present samples were determined. Results reveal that the values of energy gap in direct transition are greater than those of indirect, before and after irradiation. (Egap), (Ea), (N), (M), and (n) of the present samples are changed significantly with irradiation time and value of alpha energy. Results reflect the possibility of using DAM-ADC polymer track detectors to estimate alpha particle energies using the variation of the absorbance.

  5. Automated Performance Characterization of DSN System Frequency Stability Using Spacecraft Tracking Data

    Science.gov (United States)

    Pham, Timothy T.; Machuzak, Richard J.; Bedrossian, Alina; Kelly, Richard M.; Liao, Jason C.

    2012-01-01

    This software provides an automated capability to measure and qualify the frequency stability performance of the Deep Space Network (DSN) ground system, using daily spacecraft tracking data. The results help to verify if the DSN performance is meeting its specification, therefore ensuring commitments to flight missions; in particular, the radio science investigations. The rich set of data also helps the DSN Operations and Maintenance team to identify the trends and patterns, allowing them to identify the antennas of lower performance and implement corrective action in a timely manner. Unlike the traditional approach where the performance can only be obtained from special calibration sessions that are both time-consuming and require manual setup, the new method taps into the daily spacecraft tracking data. This new approach significantly increases the amount of data available for analysis, roughly by two orders of magnitude, making it possible to conduct trend analysis with good confidence. The software is built with automation in mind for end-to-end processing. From the inputs gathering to computation analysis and later data visualization of the results, all steps are done automatically, making the data production at near zero cost. This allows the limited engineering resource to focus on high-level assessment and to follow up with the exceptions/deviations. To make it possible to process the continual stream of daily incoming data without much effort, and to understand the results quickly, the processing needs to be automated and the data summarized at a high level. Special attention needs to be given to data gathering, input validation, handling anomalous conditions, computation, and presenting the results in a visual form that makes it easy to spot items of exception/deviation so that further analysis can be directed and corrective actions followed.

  6. Real-time optical multiple object recognition and tracking system and method

    Science.gov (United States)

    Chao, Tien-Hsin (Inventor); Liu, Hua-Kuang (Inventor)

    1990-01-01

    System for optically recognizing and tracking a plurality of objects within a field of vision. Laser (46) produces a coherent beam (48). Beam splitter (24) splits the beam into object (26) and reference (28) beams. Beam expanders (50) and collimators (52) transform the beams (26, 28) into coherent collimated light beams (26', 28'). A two-dimensional SLM (54), disposed in the object beam (26'), modulates the object beam with optical information as a function of signals from a first camera (16) which develops X and Y signals reflecting the contents of its field of vision. A hololens (38), positioned in the object beam (26') subsequent to the modulator (54), focuses the object beam at a plurality of focal points (42). A planar transparency-forming film (32), disposed with the focal points on an exposable surface, forms a multiple position interference filter (62) upon exposure of the surface and development processing of the film (32). A reflector (53) directing the reference beam (28') onto the film (32), exposes the surface, with images focused by the hololens (38), to form interference patterns on the surface. There is apparatus (16', 64) for sensing and indicating light passage through respective ones of the positions of the filter (62), whereby recognition of objects corresponding to respective ones of the positions of the filter (62) is affected. For tracking, apparatus (64) focuses light passing through the filter (62) onto a matrix of CCD's in a second camera (16') to form a two-dimensional display of the recognized objects.

  7. Observation of wave packet dichotomy and adiabatic stabilization in an optical waveguide

    International Nuclear Information System (INIS)

    Longhi, S.; Marangoni, M.; Janner, D.; Ramponi, R.; Laporta, P.; Cianci, E.; Foglietti, V.

    2005-01-01

    We report on the first experimental observation of wave packet dichotomy and adiabatic stabilization of light in a periodically bent optical waveguide in analogy with similar behavior of atoms in high-frequency strong laser fields

  8. Segment Tracking via a Spatiotemporal Linking Process including Feedback Stabilization in an n-D Lattice Model

    Directory of Open Access Journals (Sweden)

    Florentin Wörgötter

    2009-11-01

    Full Text Available Model-free tracking is important for solving tasks such as moving-object tracking and action recognition in cases where no prior object knowledge is available. For this purpose, we extend the concept of spatially synchronous dynamics in spin-lattice models to the spatiotemporal domain to track segments within an image sequence. The method is related to synchronization processes in neural networks and based on superparamagnetic clustering of data. Spin interactions result in the formation of clusters of correlated spins, providing an automatic labeling of corresponding image regions. The algorithm obeys detailed balance. This is an important property as it allows for consistent spin-transfer across subsequent frames, which can be used for segment tracking. Therefore, in the tracking process the correct equilibrium will always be found, which is an important advance as compared with other more heuristic tracking procedures. In the case of long image sequences, i.e., movies, the algorithm is augmented with a feedback mechanism, further stabilizing segment tracking.

  9. Identifying and tracking evolving water masses in optically complex aquatic environments

    Science.gov (United States)

    Palacios, Sherry L.

    Earth's climate is intimately associated with biogeochemical processes of the sea. Biological Oceanography explores mechanisms controlling carbon uptake by phytoplankton, carbon transfer through biogeochemical processes, and energy flow through ecosystems. Satellite Oceanography affords a synoptic view of the sea surface and reveals underlying physical, chemical, and biological processes. Since the advent of ocean color satellites in 1978, ocean color algorithms evolved from quantifying phytoplankton biomass to addressing more complex bio-optical and oceanographic problems: characterizing inherent optical properties of the water column, estimating primary productivity, and detecting water masses. Locating a water mass, tracking its changes, and discriminating its constituents using bio-optical algorithms are the three objectives of this dissertation. The first objective identifies the location of the Columbia River Plume (CRP) by using light absorption by chromophoric dissolved organic matter (a CDOM) as an optical proxy for salinity. It relates in situ measurements of (a CDOM to salinity using linear regression analysis, then computes "synthetic" salinity using MODIS-Aqua satellite imagery. The algorithm is robust at predicting salinity of the CRP on the Oregon and Washington shelf. The second objective identifies sub-mesoscale features within the CRP and tracks their changes in space and time. It employs k-means clustering and discriminant function analysis to identify water types from bio-optical and environmental input variables using in situ and MODIS-Aqua satellite observations. The algorithm is robust at identifying features in satellite and mooring data, consistent with measured and modeled water masses in previous work. The third objective involves development of an optical model (PHYDOTax) that discriminates phytoplankton taxa contained within an algal bloom. A hyperspectral ocean color signature-library for known phytoplankton (dinoflagellates, diatoms

  10. Strain monitoring of a newly developed precast concrete track for high speed railway traffic using embedded fiber optic sensors

    Science.gov (United States)

    Crail, Stephanie; Reichel, D.; Schreiner, U.; Lindner, E.; Habel, Wolfgang R.; Hofmann, Detlef; Basedau, Frank; Brandes, K.; Barner, A.; Ecke, Wolfgang; Schroeder, Kerstin

    2002-07-01

    In a German slab track system (Feste Fahrbahn FF, system Boegl) for speeds up to 300 km/h and more different fiber optic sensors have been embedded in several levels and locations of the track system. The track system consists of prestressed precast panels of steel fiber concrete which are supported by a cat-in-situ concrete or asphalt base course. The sensors are to measure the bond behavior or the stress transfer in the track system. For that, tiny fiber-optic sensors - fiber Fabry-Perot and Bragg grating sensors - have been embedded very near to the interface of the layers. Measurements were taken on a full scale test sample (slab track panel of 6.45 m length) as well as on a real high speed track. The paper describes the measurement task and discusses aspects with regard to sensor design and prefabrication of the sensor frames as well as the embedding procedure into the concrete track. Results from static and dynamic full scale tests carried out in the testing laboratory of BAM and from measurements on a track are given.

  11. Self-stabilizing optical clock pulse-train generator using SOA and saturable absorber for asynchronous optical packet processing.

    Science.gov (United States)

    Nakahara, Tatsushi; Takahashi, Ryo

    2013-05-06

    We propose a novel, self-stabilizing optical clock pulse-train generator for processing preamble-free, asynchronous optical packets with variable lengths. The generator is based on an optical loop that includes a semiconductor optical amplifier (SOA) and a high-extinction spin-polarized saturable absorber (SA), with the loop being self-stabilized by balancing out the gain and absorption provided by the SOA and SA, respectively. The optical pulse train is generated by tapping out a small portion of a circulating seed pulse. The convergence of the generated pulse energy is enabled by the loop round-trip gain function that has a negative slope due to gain saturation in the SOA. The amplified spontaneous emission (ASE) of the SOA is effectively suppressed by the SA, and a backward optical pulse launched into the SOA enables overcoming the carrier-recovery speed mismatch between the SOA and SA. Without external control for the loop gain, a stable optical pulse train consisting of more than 50 pulses with low jitter is generated from a single 10-ps seed optical pulse even with a variation of 10 dB in the seed pulse intensity.

  12. Stability and change in physical activity levels: a literature rewiew based in the concept and values of tracking

    Directory of Open Access Journals (Sweden)

    Catarina Margarida da Silva Vasques

    2005-12-01

    Full Text Available The main purposes of this paper is to review the concepts of stability and tracking, as well as the main results from longitudinal studies focusing on physical activity. We explain the different meanings of stability: structural, normative or covariance, level or means, and ipsative. We also look at tracking issues, its different meanings and ways of computation. The main results from physical activity studies do show that, in general, stability varies from low to moderate values. These results challenge researchers from different fields of study, from epidemiologists to physical education teachers. RESUMO Esta revisão pretende efectuar uma abordagem aos conceitos de estabilidade e tracking, bem como resumir os principais resultados de estudos longitudinais sobre estabilidade da actividade física. Faz-se a distinção entre os diferentes tipos de estabilidade: estrutural, normativa ou da covariância, de nível ou das médias, e ipsativa. Aborda-se a problemática do tracking, da sua multiplicidade de significações e operacionalizações. Os principais resultados sobre a estabilidade da actividade física salientam, que na generalidade, os seus valores são baixos a moderados. Este quadro genérico coloca desafios à investigação de inúmeros pesquisadores, desde epidemiologistas a professores de educação física.

  13. Acquisition, tracking, and pointing IV; Proceedings of the Meeting, Orlando, FL, Apr. 19, 20, 1990

    Science.gov (United States)

    Gowrinathan, Sankaran

    1990-09-01

    Various papers on acquisition, tracking, and pointing are presented. Individual topics addressed include: backlash control techniques in geared servo mechanics; optical fiber and photodetector array for robotic seam tracking; star trackers for spacecraft applications; Starfire optical range tracking system for the 1.5 m telescope; real-time video image centroid tracker; optical alignment with a beamwalk system; line-of-sight stabilization requirements for target tracking system; image quality with narrow beam illumination in an active tracking system; IR sensor data fusion for target detection, identification, and tracking; target location and pointing algorithm for a three-axis stabilized line scanner. Also discussed are: adaptive control system techniques applied to inertial stabilization systems; supervisory control of electrooptic tracking and pointing; position loop compensation for flex-pivot-mounted gimbal stabilization systems; advanced testing methods for acquisition, tracking, and pointing; development of kinmatics for gimballed mirror systems.

  14. Modeling the Stability of Topological Matter in Optical Lattices

    Science.gov (United States)

    2013-05-18

    interactions between fermions in an optical lattice. And finally, in section 3D , I discuss results that studies strong interaction and strong spin...in the conventional bosonization approach. 3D : Dzyaloshinskii-Moriya Interaction and Spiral Order in Spin-orbit Coupled Optical Lattices In this work...is of the same order as the Heisenberg coupling constant, J. (II) We study the phase diagram of the effective spin model using classical Monte Carlo

  15. Fiber optic transmission line stabilization apparatus and method

    Science.gov (United States)

    Lutes, G. F., Jr.; Lau, K. Y. (Inventor)

    1981-01-01

    A reference signal of RF frequency modulates a 0.85 micrometer wavelength optical transmitter. The output of which passes through a first optical filter and a voltage-controller phase shifter. The output of the phase shifter is provided to the fiber optic transmission line. At the receiving end of the transmission line, the signal is demodulated and used to modulate a 1.06 micrometer optical transmitter. The signal from the transmitter is provided to the fiber optic transmission line and passes through the voltage-controlled phase shifter to a phase error detector. The phase of the modulation of the 1.06 micrometer wavelength signal is compared to the phase of the reference signal by the phase error detector. A phase control signal related to the phase difference is provided to the voltage controlled phase shifter which alters the phase of both optical signals until a predetermined phase relationship between modulation on the 1.06 micrometer signal and the reference signal is obtained.

  16. Oligochitosan-stabilized photoluminescent gold nanoconstructs for optical bioimaging

    OpenAIRE

    Yoo, Donghyuck; Lee, Dongwon

    2017-01-01

    Background Gold nanoclusters (AuNCs) are typically composed of several to tens of gold atoms which are stabilized with biomacromolecules such as bovine serum albumin (BSA). Au NCs fluoresces in the visible to near infrared region, in a size-dependent manner. AuNCs solutions have potential as fluorophore in a wide range of biomedical applications such as biodetection, biosensing and bioimaging in vitro and in vivo. However, their stability and harsh condition of preparation limit their biomedi...

  17. A Surface-Coupled Optical Trap with 1-bp Precision via Active Stabilization.

    Science.gov (United States)

    Okoniewski, Stephen R; Carter, Ashley R; Perkins, Thomas T

    2017-01-01

    Optical traps can measure bead motions with Å-scale precision. However, using this level of precision to infer 1-bp motion of molecular motors along DNA is difficult, since a variety of noise sources degrade instrumental stability. In this chapter, we detail how to improve instrumental stability by (1) minimizing laser pointing, mode, polarization, and intensity noise using an acousto-optical-modulator mediated feedback loop and (2) minimizing sample motion relative to the optical trap using a three-axis piezo-electric-stage mediated feedback loop. These active techniques play a critical role in achieving a surface stability of 1 Å in 3D over tens of seconds and a 1-bp stability and precision in a surface-coupled optical trap over a broad bandwidth (Δf = 0.03-2 Hz) at low force (6 pN). These active stabilization techniques can also aid other biophysical assays that would benefit from improved laser stability and/or Å-scale sample stability, such as atomic force microscopy and super-resolution imaging.

  18. Fatigue crack monitoring in train track steel structures using plastic optical fiber sensor

    Science.gov (United States)

    Yang, D.; Li, D.; Kuang, K. S. C.

    2017-10-01

    Plastic optical fiber (POF) sensors have shown excellent potential for damage detection and structural health monitoring in a variety of engineering structures. This paper discusses the feasibility of using POF sensors in conjunction with a signal-processing algorithm capable of detecting and monitoring fatigue-induced cracks in train track steel structures in real time. The POF sensor, which was modified from an existing design to increase the signal sensitivity, allows for accurate detection of a fatigue crack developed in a specimen, and was found to compare well to the reference acoustic emission (AE) sensors and crack opening displacement (COD) gauge attached to the specimen. The crack-detection technique, which relies on capturing the intensity variation of the POF sensor, was not susceptible to any signal fluctuations commonly associated with intensity-based optical fiber sensors. The results show that the technique has potential for use in detecting the initiation and propagation of specific segments of a structure vulnerable to cracking due to external cyclic loading, e.g. at welded joints in train tracks under train loads or offshore structures subject to wave loads. The POF sensor system is composed of inexpensive parts (LED light source, photodetectors, and data acquisition units) and can easily be installed to the host structure. To validate the proposed damage-detection technique, the instrumented specimens are subjected to cyclic loading in order to induce stable crack propagation in the specimen. A COD gauge and AE were used for the purpose of calibration and comparison. The results show remarkable resemblance in terms of crack initiation and propagation identification exhibited by all three types of sensors, highlighting the potential of the proposed sensor for crack initiation detection and subsequent monitoring of crack propagation.

  19. Stability of Markers Used for Real-Time Tumor Tracking After Percutaneous Intrapulmonary Placement

    International Nuclear Information System (INIS)

    Voort van Zyp, Noelle C. van der; Hoogeman, Mischa S.; Water, Steven van de; Levendag, Peter C.; Holt, Bronno van der; Heijmen, Ben J.M.; Nuyttens, Joost J.

    2011-01-01

    Purpose: To determine the stability of markers used for real-time tumor tracking after percutaneous intrapulmonary placement. Methods and Materials: A total of 42 patients with 44 lesions, 111 markers, and ≥2 repeat computed tomography (CT) scans were studied. The tumor on the repeat CT scans was registered with the tumor on the planning CT scan. Next, the three-dimensional marker coordinates were determined on the planning CT scan and repeat CT scans. Marker stability was analyzed by the displacement of the markers and the displacement of the center of mass (COM) of the marker configurations. In addition, we assessed the reliability of using the intermarker distance as a check for displacements in the COM of the marker configurations. Results: The median marker displacement was 1.3 mm (range, 0.1-53.6). The marker displacement was >5 mm in 12% of the markers and >10 mm in 5% of the markers. The causes of marker displacement >5 mm included marker migration (2 of 13) and target volume changes (5 of 13). Nonsynchronous tumor and marker movement during breathing might have been responsible for the displacements >5 mm in the other 6 of 13 markers. The median displacement in the COM of the marker configurations was 1.0 mm (range, 0.1-23.3). Displacements in the COM of the marker configurations of ≥2.0 mm were detected by changes in the intermarker distance of >1.5 mm in 96% of the treatment fractions. Conclusion: The median marker displacement was small (1.3 mm). Nevertheless, displacements >5 mm occurred in 12% of the markers. Therefore, we recommend the implantation of multiple markers because multiple markers will enable a quick and reliable check of marker displacement by determining the change in the intermarker distance. A displacement in the COM of the marker configuration of ≥2.0 mm was almost always detected (96%) by a change in the distance between the markers of >1.5 mm. This enabled the displaced marker to be disabled, such that tumor localization was

  20. On the optical stability of high-resolution transmission electron microscopes

    International Nuclear Information System (INIS)

    Barthel, J.; Thust, A.

    2013-01-01

    In the recent two decades the technique of high-resolution transmission electron microscopy experienced an unprecedented progress through the introduction of hardware aberration correctors and by the improvement of the achievable resolution to the sub-Ångström level. The important aspect that aberration correction at a given resolution requires also a well defined amount of optical stability has received little attention so far. Therefore we investigate the qualification of a variety of high-resolution electron microscopes to maintain an aberration corrected optical state in terms of an optical lifetime. We develop a comprehensive statistical framework for the estimation of the optical lifetime and find remarkably low values between tens of seconds and a couple of minutes. Probability curves are introduced, which inform the operator about the chance to work still in the fully aberration corrected state. - Highlights: • We investigate the temporal stability of optical aberrations in HRTEM. • We develop a statistical framework for the estimation of optical lifetimes. • We introduce plots showing the success probability for aberration-free work. • Optical lifetimes in sub-Ångström electron microscopy are surprisingly low. • The success of aberration correction depends strongly on the optical stability

  1. Historical Building Stability Monitoring by Means of a Cosmic Ray Tracking System

    Energy Technology Data Exchange (ETDEWEB)

    Zenoni, Aldo [Department of Mechanical and Industrial Engineering of the University of Brescia, Via Branze 38, 25123 Brescia (Italy); INFN Sezione di Pavia, Via Bassi 6, 27100 Pavia (Italy)

    2015-07-01

    Cosmic ray radiation is mostly composed, at sea level, by high energy muons, which are highly penetrating particles capable of crossing kilometers of rock. The ubiquitous and steady presence at the Earth's surface and the high penetration capability have motivated the use of cosmic ray radiation also in fields beyond particle physics, from geology, archaeology, speleology to industrial applications and homeland security. In particular, in recent years, the novel technique of muon tomography has been proposed, with the aim of performing non invasive inspection of large non accessible volumes, material atomic number Z and density discrimination, and three dimension image reconstruction of the inspected volume. In the present paper, after a short recall of the physical principles and mathematical formalism on which muon tomography is based, a number of examples of application of the novel technique in industry and homeland security issues is given. Moreover, a new application of cosmic rays detection techniques in the field of civil engineering is proposed. The aim is the monitoring of the stability of large structures, in particular the static monitoring of historical buildings, where conservation constraints are more severe and the time evolution of the deformation phenomena under study may be of the order of months or years. The new technique may be seen, in some way, as the reverse problem of muon tomography. As a significant case study, the monitoring of the wooden vaulted roof of the Palazzo della Loggia in the town of Brescia, in Italy, has been considered. The feasibility as well as the performances and limitations of a monitoring system based on cosmic ray tracking have been studied by Monte Carlo simulation and discussed in comparison with more traditional monitoring systems. (authors)

  2. Developing new optical imaging techniques for single particle and molecule tracking in live cells

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Wei [Iowa State Univ., Ames, IA (United States)

    2010-01-01

    Differential interference contrast (DIC) microscopy is a far-field as well as wide-field optical imaging technique. Since it is non-invasive and requires no sample staining, DIC microscopy is suitable for tracking the motion of target molecules in live cells without interfering their functions. In addition, high numerical aperture objectives and condensers can be used in DIC microscopy. The depth of focus of DIC is shallow, which gives DIC much better optical sectioning ability than those of phase contrast and dark field microscopies. In this work, DIC was utilized to study dynamic biological processes including endocytosis and intracellular transport in live cells. The suitability of DIC microscopy for single particle tracking in live cells was first demonstrated by using DIC to monitor the entire endocytosis process of one mesoporous silica nanoparticle (MSN) into a live mammalian cell. By taking advantage of the optical sectioning ability of DIC, we recorded the depth profile of the MSN during the endocytosis process. The shape change around the nanoparticle due to the formation of a vesicle was also captured. DIC microscopy was further modified that the sample can be illuminated and imaged at two wavelengths simultaneously. By using the new technique, noble metal nanoparticles with different shapes and sizes were selectively imaged. Among all the examined metal nanoparticles, gold nanoparticles in rod shapes were found to be especially useful. Due to their anisotropic optical properties, gold nanorods showed as diffraction-limited spots with disproportionate bright and dark parts that are strongly dependent on their orientation in the 3D space. Gold nanorods were developed as orientation nanoprobes and were successfully used to report the self-rotation of gliding microtubules on kinesin coated substrates. Gold nanorods were further used to study the rotational motions of cargoes during the endocytosis and intracellular transport processes in live mammalian

  3. High colloidal stability of gold nanorods coated with a peptide-ethylene glycol: Analysis by cyanide-mediated etching and nanoparticle tracking analysis.

    Science.gov (United States)

    Free, Paul; Conger, Gao; Siji, Wu; Zhang, Jing Bo; Fernig, David G

    2016-10-01

    The stability of gold nanorods was assessed following coating with various charged or uncharged ligands, mostly peptides. Highly stable monodispersed gold nanorods were obtained by coating CTAB-stabilized gold nanorods with a pentapeptide with C-terminal ethylene glycol units (peptide-EG). UV-vis spectroscopy of these nanorods suspended in saline solutions indicated no signs of aggregation, and they were easily purified using size-exclusion chromatography. A more stringent measure of nanorod stability involved observing changes in the UV-vis absorbance of gold nanorods subjected to etching with cyanide. The λmax absorbance of peptide-EG coated nanorods red-shifted in etchant solution. The hypothesis that changes in the nanorod aspect ratio led to this red-shift was confirmed by TEM analysis, which showed pit formation along the transverse axis. The etching process was followed in solution using nanoparticle tracking analysis. The red-shift was shown to occur while the particles remained mono-dispersed, and so was not due to aggregation. Adding both etchant solution and peptide-EG to the nanorods was further shown to allow modulation of the Δλmax red-shift and increase the etchant resistance of peptide-EG nanorods. Thus, very stable gold nanorods can be produced using the peptide-EG coating approach and their optical properties modulated with etchant. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Improvement of Laser Frequency Stabilization for the Optical Pumping Cesium Beam Standard

    International Nuclear Information System (INIS)

    Wang Qing; Duan Jun; Qi Xiang-Hui; Zhang Yin; Chen Xu-Zong

    2015-01-01

    A method is presented to improve the laser frequency stabilization for the optical pumping cesium clock. By comparing the laser frequency stabilization of different schemes, we verify that the light angle is an important factor that limits the long-term frequency stability. We minimize the drift of the light angle by using a fiber-coupled output, and lock the frequency of a distributed-feedback diode laser to the fluorescence spectrum of the atomic beam. The measured frequency stability is about 3.5 × 10 −11 at 1 s and reaches 1.5 × 10 −12 at 2000 s. The Allan variance keeps going down for up to thousands of seconds, indicating that the medium- and long-term stability of the laser frequency is significantly improved and perfectly fulfills the requirement for the optical pumping cesium clock. (paper)

  5. Three-dimensional automated nanoparticle tracking using Mie scattering in an optical microscope.

    Science.gov (United States)

    Gineste, J-M; Macko, P; Patterson, E A; Whelan, M P

    2011-08-01

    The forward scattering of light in a conventional inverted optical microscope by nanoparticles ranging in diameter from 10 to 50nm has been used to automatically and quantitatively identify and track their location in three-dimensions with a temporal resolution of 200ms. The standard deviation of the location of nominally stationary 50-nm-diameter nanoparticles was found to be about 50nm along the light path and about 5nm in the plane perpendicular to the light path. The method is based on oscillating the microscope objective along the light path using a piezo actuator and acquiring images with the condenser aperture closed to a minimum to enhance the effects of diffraction. Data processing in the time and spatial domains allowed the location of particles to be obtained automatically so that the technique has potential applications both in the processing of nanoparticles and in their use in a variety of fields including nanobiotechnology, pharmaceuticals and food processing where a simple optical microscope maybe preferred for a variety of reasons. © 2011 The Authors Journal of Microscopy © 2011 Royal Microscopical Society.

  6. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study

    NARCIS (Netherlands)

    Barsingerhorn, A.D.; Boonstra, F.N.; Goossens, H.H.L.M.

    2017-01-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different

  7. First test model of the optical microscope which images the whole vertical particle tracks without any depth scanning

    International Nuclear Information System (INIS)

    Soroko, L.M.

    2001-01-01

    The first test model of the optical microscope which produces the in focus image of the whole vertical particle track without depth scanning is described. The in focus image of the object consisting of the linear array of the point-like elements was obtained. A comparison with primary out of focus image of such an object has been made

  8. Development of a percutaneous optical imaging system for tracking vascular gene expression: a feasibility study using human tissuelike phantoms

    Science.gov (United States)

    Kar, Sourav K.; Kumar, Ananda; Yang, Xiaoming

    2004-05-01

    Noninvasive tracking of vascular gene delivery and expression forms an important part of successfully implementing vascular gene therapy methods for the treatment of atherosclerosis and various cardiovascular disorders. While ultrasound and MR imaging have shown promise in the monitoring of gene delivery to the vasculatures, optical imaging has shown promise for tracking gene expression. Optical imaging using bioreporter genes like Green Fluorescent Protein (GFP), Red Fluorescent Protein (RFP) and Luciferase to track and localize the therapeutic gene have helped provide an in vivo detection method of the process. The usage of GFP and RFP entails the detection of the fluorescent signal emitted by them on excitation with light of appropriate wavelength. We have developed a novel percutaneous optical imaging system that may be used for in vivo tracking vascular fluorescent gene expression in deep-seated vessels. It is based on the detection of the fluorescent signal emitted from GFP tagged cells. This phantom study was carried out to investigate the performance of the optical imaging system and gain insights into its performance record and study improvisation possibilities.

  9. A comparative study between the imaging system and the optical tracking system in proton therapy at CNAO

    CERN Document Server

    Desplanques, Maxime; Fontana, Giulia; Pella, Andrea; Riboldi, Marco; Fattori, Giovanni; Donno, Andrea; Baroni, Guido; Orecchia, Roberto

    2013-01-01

    The synergy between in-room imaging and optical tracking, in co-operation with highly accurate robotic patient handling represents a concept for patient-set-up which has been implemented at CNAO (Centro Nazionale di Adroterapia Oncologica). In-room imaging is based on a double oblique X-ray projection system; optical tracking consists of the detection of the position of spherical markers placed directly on the patient’s skin or on the immobilization devices. These markers are used as external fiducials during patient positioning and dose delivery. This study reports the results of a comparative analysis between in-room imaging and optical tracking data for patient positioning within the framework of high-precision particle therapy. Differences between the optical tracking system (OTS) and the imaging system (IS) were on average within the expected localization accuracy. On the first 633 fractions for head and neck (H&N) set-up procedures, the corrections applied by the IS, after patient positioning usin...

  10. Optics of the human cornea influence the accuracy of stereo eye-tracking methods: a simulation study.

    Science.gov (United States)

    Barsingerhorn, A D; Boonstra, F N; Goossens, H H L M

    2017-02-01

    Current stereo eye-tracking methods model the cornea as a sphere with one refractive surface. However, the human cornea is slightly aspheric and has two refractive surfaces. Here we used ray-tracing and the Navarro eye-model to study how these optical properties affect the accuracy of different stereo eye-tracking methods. We found that pupil size, gaze direction and head position all influence the reconstruction of gaze. Resulting errors range between ± 1.0 degrees at best. This shows that stereo eye-tracking may be an option if reliable calibration is not possible, but the applied eye-model should account for the actual optics of the cornea.

  11. Long-term optical stability of fluorescent solar concentrator plates

    NARCIS (Netherlands)

    Slooff, Lenneke H.; Bakker, Nicolaas J.; Sommeling, Paul M.; Büchtemann, Andreas; Wedel, Armin; Van Sark, Wilfried G J H M

    2014-01-01

    Fluorescent solar concentrators offer an alternative approach for low-cost photovoltaic energy conversion. For successful application, not only the power conversion efficiency and cost are important, but also lifetime or stability of the devices. As today's concentrator is made of polymer sheets

  12. Laser frequency stabilization using linear magneto-optics

    International Nuclear Information System (INIS)

    Yashchuk, Valeriy V.; Budker, Dmitry; Davis, John R.

    2000-01-01

    The design of a diode laser frequency stabilization system using the Zeeman effect is described. Various regimes of operation are analyzed using the Jones matrix approach. The system is different from the original Joint Institute for Laboratory Astrophysics design in that the magnetic fields are fully contained and thus it can be used in proximity of magnetically sensitive instruments. (c) 2000 American Institute of Physics

  13. Bitumen stabilized ballast: a potential solution for railway track-bed

    OpenAIRE

    D'Angelo, Giacomo; Thom, Nicholas; Lo Presti, Davide

    2016-01-01

    Railway ballast degradation under dynamic loads progressively leads to loss of mechanical performance and geometry of the track, so that maintenance interventions are frequently needed. In order to systematically avoid this issue, recently solutions have been proposed to reinforce track-bed by using polyurethane and/or resins as well as asphalt layers among others. Nonetheless, their main limitations are related to the high initial cost and low productivity.\\ud To cope with these limitations,...

  14. Using optical soliton stability for magnetic field measurement

    Science.gov (United States)

    Şchiopu, IonuÅ£ Romeo; ǎgulinescu, Andrei, Dr; Marinescu, Andrei

    2015-02-01

    In this paper we propose a novel optical method for measuring the circular magnetic field. In practice, many situations may appear in which there are difficulties in measuring the magnetic field, as inside coils, motors etc., where the magnetic field lines are circular or elliptical. The proposed method, applied for measuring the current on high voltage lines, strongly benefits from the advantages that it offers as compared to classical solutions based on the inductive principle. Some of the advantages of optoelectronic and optic measurement methods have a real importance. These advantages consist in: avoiding the use of energy intensive materials (Cu, Fe etc.), reducing the weight of the measuring system, reducing at the minimum the fire danger due to the use of paper-oil insulation in high voltage devices etc. The novelty of our proposed method consists in using the electromagnetic radiation in ultrashort pulses, having a relatively large frequency band and a much improved resistance to external perturbations, for measuring the circular magnetic field generated from the current of high voltage lines, inside power transformers or high power motors.

  15. Low cost heads-up virtual reality (HUVR) with optical tracking and haptic feedback

    Science.gov (United States)

    Margolis, Todd; DeFanti, Thomas A.; Dawe, Greg; Prudhomme, Andrew; Schulze, Jurgen P.; Cutchin, Steve

    2011-03-01

    Researchers at the University of California, San Diego, have created a new, relatively low-cost augmented reality system that enables users to touch the virtual environment they are immersed in. The Heads-Up Virtual Reality device (HUVR) couples a consumer 3D HD flat screen TV with a half-silvered mirror to project any graphic image onto the user's hands and into the space surrounding them. With his or her head position optically tracked to generate the correct perspective view, the user maneuvers a force-feedback (haptic) device to interact with the 3D image, literally 'touching' the object's angles and contours as if it was a tangible physical object. HUVR can be used for training and education in structural and mechanical engineering, archaeology and medicine as well as other tasks that require hand-eye coordination. One of the most unique characteristics of HUVR is that a user can place their hands inside of the virtual environment without occluding the 3D image. Built using open-source software and consumer level hardware, HUVR offers users a tactile experience in an immersive environment that is functional, affordable and scalable.

  16. Low cost heads-up virtual reality (HUVR) with optical tracking and haptic feedback

    KAUST Repository

    Margolis, Todd

    2011-01-23

    Researchers at the University of California, San Diego, have created a new, relatively low-cost augmented reality system that enables users to touch the virtual environment they are immersed in. The Heads-Up Virtual Reality device (HUVR) couples a consumer 3D HD flat screen TV with a half-silvered mirror to project any graphic image onto the user\\'s hands and into the space surrounding them. With his or her head position optically tracked to generate the correct perspective view, the user maneuvers a force-feedback (haptic) device to interact with the 3D image, literally \\'touching\\' the object\\'s angles and contours as if it was a tangible physical object. HUVR can be used for training and education in structural and mechanical engineering, archaeology and medicine as well as other tasks that require hand-eye coordination. One of the most unique characteristics of HUVR is that a user can place their hands inside of the virtual environment without occluding the 3D image. Built using open-source software and consumer level hardware, HUVR offers users a tactile experience in an immersive environment that is functional, affordable and scalable.

  17. Facial acquisition by dynamic optical tracked laser imaging: a new approach.

    Science.gov (United States)

    Schwenzer-Zimmerer, K; Boerner, B-I; Schwenzer, N F; Müller, A A; Juergens, P; Ringenbach, A; Schkommodau, E; Zeilhofer, H-F

    2009-09-01

    Three-dimensional capture of the surface of soft tissue is a desirable support for documentation and therapy planning in plastic and reconstructive surgery concerning the complex anatomy of the face, particularly cleft lip and palate (CLP). Different scanning systems are used for capturing facial surfaces. These systems are mostly based on a static linear measuring arrangement. Established systems work on the basis of coded white light or linear laser triangulation and digital stereophotogrammetric approaches. Shadowing effects occur with these devices. These effects may be avoided by a radical new approach first used in automotive industries that employs a mobile, flexible handheld laser scanner with simultaneous registration by optical tracking. The aim of this study was to assess the suitability of this scanner for surgical procedures on the human face in operating theatre. Five babies aged about 3 months with cleft deformities (one CLP, one bilateral CLP, three isolated cleft lips) were captured directly: twice preoperatively, twice postoperatively and twice after 7 days. An industrial standard specimen and two plaster cast masks of CLP babies were taken and subsequently measured to assess reliability and validity of the device. Masks were measured to reflect the complex surface of the cleft deformity. Data evaluation was done with respect to completeness of the data sets, as well as reliability and validity of the system. Missing data caused by shadowing could be avoided in all images. Even complex areas with undercuts could be reproduced completely and precisely with an accuracy in the sub-millimetre range.

  18. A survey of head movement during clinical brain SPECT using an optical tracking system

    International Nuclear Information System (INIS)

    Pandos, G.; Barnden, L.; Lineage, H.; Smith, T.; Unger, S.

    2002-01-01

    Full text: The aim of this study was to survey patient motion during clinical brain SPECT using a commercial motion detection system called Polaris. Polaris is an optical tracker that remotely tracks head position and orientation via a small target attached to the patient. Its accuracy for position measurement is 1mm or 1 degree (deg), 33% moved > 2mm or 2deg and 10% moved > 4mm or 4deg. 65% of subjects moved 3 or more times. Motion in the D and P groups was equally likely to be small (<3mm or <3deg) or large and equally likely to occur early or late during acquisition. Motion in the N, F and C groups was less likely to be large and for N and F more likely to occur late in the acquisition suggesting fatigue was the main cause. The most common large movements were anterior-posterior translations and axial (Z) rotations. Significant head movement is common in brain SPECT, particularly in dementia and psychiatric subjects, and accurate motion correction is desirable to maintain image quality. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  19. Conversion of Stability of Femtosecond Stabilized Mode-locked Laser to Optical Cavity Length

    Czech Academy of Sciences Publication Activity Database

    Šmíd, Radek; Číp, Ondřej; Čížek, Martin; Mikel, Břetislav; Lazar, Josef

    2010-01-01

    Roč. 57, č. 3 (2010), s. 636-640 ISSN 0885-3010 R&D Projects: GA ČR GA102/09/1276; GA MŠk(CZ) LC06007; GA MŠk 2C06012; GA MPO 2A-1TP1/127; GA MPO FT-TA3/133; GA MPO 2A-3TP1/113; GA ČR GA102/07/1179 Institutional research plan: CEZ:AV0Z20650511 Keywords : laser * Fabry-Perot * interferometer * length etalon Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.460, year: 2010

  20. Habitat stability affects dispersal and the ability to track climate change

    DEFF Research Database (Denmark)

    Hof, Christian; Brändle, Martin; Dehling, D. Matthias

    2012-01-01

    Habitat persistence should influence dispersal ability, selecting for stronger dispersal in habitats of lower temporal stability. As standing (lentic) freshwater habitats are on average less persistent over time than running (lotic) habitats, lentic species should show higher dispersal abilities ...

  1. On the optical stability of high-resolution transmission electron microscopes.

    Science.gov (United States)

    Barthel, J; Thust, A

    2013-11-01

    In the recent two decades the technique of high-resolution transmission electron microscopy experienced an unprecedented progress through the introduction of hardware aberration correctors and by the improvement of the achievable resolution to the sub-Ångström level. The important aspect that aberration correction at a given resolution requires also a well defined amount of optical stability has received little attention so far. Therefore we investigate the qualification of a variety of high-resolution electron microscopes to maintain an aberration corrected optical state in terms of an optical lifetime. We develop a comprehensive statistical framework for the estimation of the optical lifetime and find remarkably low values between tens of seconds and a couple of minutes. Probability curves are introduced, which inform the operator about the chance to work still in the fully aberration corrected state. © 2013 Elsevier B.V. All rights reserved.

  2. Enhancing the resonance stability of a high-Q micro/nanoresonator by an optical means

    Science.gov (United States)

    Sun, Xuan; Luo, Rui; Zhang, Xi-Cheng; Lin, Qiang

    2016-02-01

    High-quality optical resonators underlie many important applications ranging from optical frequency metrology, precision measurement, nonlinear/quantum photonics, to diverse sensing such as detecting single biomolecule, electromagnetic field, mechanical acceleration/rotation, among many others. All these applications rely essentially on the stability of optical resonances, which, however, is ultimately limited by the fundamental thermal fluctuations of the devices. The resulting thermo-refractive and thermo-elastic noises have been widely accepted for nearly two decades as the fundamental thermodynamic limit of an optical resonator, limiting its resonance uncertainty to a magnitude 10-12 at room temperature. Here we report a novel approach that is able to significantly improve the resonance stability of an optical resonator. We show that, in contrast to the common belief, the fundamental temperature fluctuations of a high-Q micro/nanoresonator can be suppressed remarkably by pure optical means without cooling the device temperature, which we term as temperature squeezing. An optical wave with only a fairly moderate power launched into the device is able to produce strong photothermal backaction that dramatically suppresses the spectral intensity of temperature fluctuations by five orders of magnitudes and squeezes the overall level (root-mean-square value) of temperature fluctuations by two orders of magnitude. The proposed approach is universally applicable to various micro/nanoresonator platforms and the optimal temperature squeezing can be achieved with an optical Q around 106-107 that is readily available in various current devices. The proposed photothermal temperature squeezing is expected to have profound impact on broad applications of high-Q cavities in sensing, metrology, and integrated nonlinear/quantum photonics.

  3. Analysis method of beam pointing stability based on optical transmission matrix

    Science.gov (United States)

    Wang, Chuanchuan; Huang, PingXian; Li, Xiaotong; Cen, Zhaofen

    2016-10-01

    Quite a lot of factors will make effects on beam pointing stability of an optical system, Among them, the element tolerance is one of the most important and common factors. In some large laser systems, it will make final micro beams spot on the image plane deviate obviously. So it is essential for us to achieve effective and accurate analysis theoretically on element tolerance. In order to make the analysis of beam pointing stability convenient and theoretical, we consider transmission of a single chief ray rather than beams approximately to stand for the whole spot deviation. According to optical matrix, we also simplify this complex process of light transmission to multiplication of many matrices. So that we can set up element tolerance model, namely having mathematical expression to illustrate spot deviation in an optical system with element tolerance. In this way, we can realize quantitative analysis of beam pointing stability theoretically. In second half of the paper, we design an experiment to get the spot deviation in a multipass optical system caused by element tolerance, then we adjust the tolerance step by step and compare the results with the datum got from tolerance model, finally prove the correction of tolerance model successfully.

  4. Stability analysis in a ROADM-based multi-channel quasi-ring optical network

    Science.gov (United States)

    Tsai, Jimmy; Wang, Zheng; Pan, Yan; Kilper, Daniel C.; Pavel, Lacra

    2015-01-01

    Future networks require dynamic physical layer capabilities to enable rapid and on-demand reconfiguration, while ensuring stability. This paper addresses stability analysis of a ROADM-based quasi-ring optical network. A ROADM-based quasi-ring is the simplest configuration in which channel power excursions can self-propagate indefinitely and be unstable. This network configuration is composed of two reconfigurable optical add-drop multiplexers (ROADMs) each equipped with a constant gain optical amplifier and a wavelength selective switch. Over the amplified spans, two sets of lightpaths (added/dropped by opposite ROADMs) are transmitted in mirror image of each other and form an overlapping ring. Sufficient stability conditions for the quasi-ring as well as an L2 bound for the channel power excursions are derived based on Lyapunov analysis and the small gain theorem. These conditions are functions of the amplifier gain coupling quantified by its Lipschitz constant. Numerical results that verify and compare the theoretical results are provided. The platform used is Bell Lab's A Transparent Optical Mesh (ATOM) simulator, set up for dynamic network loading and input channel disturbance scenarios.

  5. Instrumentation by accelerometers and distributed optical fiber sensors of a real ballastless track structure

    OpenAIRE

    CHAPELEAU, Xavier; COTTINEAU, Louis-Marie; SEDRAN, Thierry; CAILLIAU, Joël; GUEGUEN, Ivan; DUMOULIN, Jean

    2015-01-01

    While relatively expensive to build, ballastless track structures are presently seen as an attractive alternative to conventional ballast. Firstly, they are built quickly since the slabs can be cast in place in an automated fashion by a slipform paver. Secondly, with its service life of at least 60 years, they requires little maintenance and hence they offers great availability. Other reasons for using ballastless tracks instead of ballasted tracks are the lack of suitable ballast material an...

  6. Contribution of thermal noise to frequency stability of rigid optical cavity via Hertz-linewidth lasers

    International Nuclear Information System (INIS)

    Notcutt, Mark; Ma, L.-S.; Ludlow, Andrew D.; Foreman, Seth M.; Ye Jun; Hall, John L.

    2006-01-01

    We perform detailed studies of state-of-the-art laser stabilization to high finesse optical cavities, revealing fundamental mechanical thermal noise-related length fluctuations. We compare the frequency noise of lasers tightly locked to the resonances of a variety of rigid Fabry-Perot cavities of differing lengths and mirror substrate materials. The results are in agreement with the theoretical model proposed in K. Numata, A. Kemery, and J. Camp [Phys. Rev. Lett. 93, 250602 (2004)]. The results presented here on the fundamental limits of FP references will impact planning and construction of next generation ultrastable optical cavities

  7. In-plane ultrasonic needle tracking using a fiber-optic hydrophone

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E. [Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT (United Kingdom); Mari, Jean Martial [Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom and GePaSud, University of French Polynesia, Faa’a 98702, French Polynesia (France); West, Simeon J. [Department of Anaesthesia, University College Hospital, Main Theatres, Maple Bridge Link Corridor, Podium 3, 235 Euston Road, London NW1 2BU (United Kingdom); Ginsberg, Yuval; David, Anna L. [Institute for Women’s Health, University College London, 86-96 Chenies Mews, London WC1E 6HX (United Kingdom); Ourselin, Sebastien [Center for Medical Imaging Computing, University College London, Gower Street, London WC1E 6BT (United Kingdom)

    2015-10-15

    Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction with the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With

  8. Placement Stability, Cumulative Time in Care, and Permanency: Using Administrative Data from CPS to Track Placement Trajectories.

    Science.gov (United States)

    Hélie, Sonia; Poirier, Marie-Andrée; Esposito, Tonino; Turcotte, Daniel

    2017-11-17

    Objectives : The Quebec Youth Protection Act was amended in 2007. The main goal of this reform was to improve placement stability for children who are removed from their home for their protection. Among several legal provisions introduced was the establishment of maximum age-specific durations of out-of-home care, after which a plan must be established to provide stability for children placed in substitute care by finding permanent homes for them. The purpose of this study is (1) to examine trends in placement use and placement stability since the reform and (2) to document the current frequency of each type of placement setting, the cumulative time in care before the exit to permanency, and the sustainability of the permanency outcome. Methods: The study relies on 3 entry cohorts of all children investigated who received protection measures in the province of Quebec during 3 specific time frames before and after the reform ( n = 9620, 8676, 8425). Cohorts were observed for a period varying from 3 to 4 years. Administrative data from all 16 child protection agencies were used to track placement trajectory indicators and to compare cohorts. Results : There has been a decrease in the proportion of children receiving protection measures who were placed in care since the reform, and placement in kinship care has become more frequent among children placed. Placement stability improved slightly after the reform. Overall, for infants, the most frequent type of permanency attained is adoption, while reunification is the option most often indicated for older children. Some children are at a greater risk of experiencing unstable placement trajectories: young children have a high rate of reunification breakdown, some wait a long time to be adopted, and adolescents are frequently removed from the substitute care setting where they were supposed to stay until the age of 18. Conclusions : The results suggest interesting avenues for policy makers and service providers to improve

  9. Placement Stability, Cumulative Time in Care, and Permanency: Using Administrative Data from CPS to Track Placement Trajectories

    Directory of Open Access Journals (Sweden)

    Sonia Hélie

    2017-11-01

    Full Text Available Objectives: The Quebec Youth Protection Act was amended in 2007. The main goal of this reform was to improve placement stability for children who are removed from their home for their protection. Among several legal provisions introduced was the establishment of maximum age-specific durations of out-of-home care, after which a plan must be established to provide stability for children placed in substitute care by finding permanent homes for them. The purpose of this study is (1 to examine trends in placement use and placement stability since the reform and (2 to document the current frequency of each type of placement setting, the cumulative time in care before the exit to permanency, and the sustainability of the permanency outcome. Methods: The study relies on 3 entry cohorts of all children investigated who received protection measures in the province of Quebec during 3 specific time frames before and after the reform (n = 9620, 8676, 8425. Cohorts were observed for a period varying from 3 to 4 years. Administrative data from all 16 child protection agencies were used to track placement trajectory indicators and to compare cohorts. Results: There has been a decrease in the proportion of children receiving protection measures who were placed in care since the reform, and placement in kinship care has become more frequent among children placed. Placement stability improved slightly after the reform. Overall, for infants, the most frequent type of permanency attained is adoption, while reunification is the option most often indicated for older children. Some children are at a greater risk of experiencing unstable placement trajectories: young children have a high rate of reunification breakdown, some wait a long time to be adopted, and adolescents are frequently removed from the substitute care setting where they were supposed to stay until the age of 18. Conclusions: The results suggest interesting avenues for policy makers and service

  10. Ultra-Wideband Radar for Breath Tracking with Optical Fiber for Remote Reach Extension

    DEFF Research Database (Denmark)

    Suhr, Lau Frejstrup; Tafur Monroy, Idelfonso; Vegas Olmos, Juan José

    2016-01-01

    We report on the experimental demonstration of an UWB radar with fiber extension for remote breath tracking through 10 cm of concrete. The radar is based on telecom class equipment.......We report on the experimental demonstration of an UWB radar with fiber extension for remote breath tracking through 10 cm of concrete. The radar is based on telecom class equipment....

  11. Ghost marker detection and elimination in marker-based optical tracking systems for real-time tracking in stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Yan, Guanghua; Li, Jonathan; Huang, Yin; Mittauer, Kathryn; Lu, Bo; Liu, Chihray

    2014-01-01

    Purpose: To propose a simple model to explain the origin of ghost markers in marker-based optical tracking systems (OTS) and to develop retrospective strategies to detect and eliminate ghost markers. Methods: In marker-based OTS, ghost markers are virtual markers created due to the cross-talk between the two camera sensors, which can lead to system execution failure or inaccuracy in patient tracking. As a result, the users have to limit the number of markers and avoid certain marker configurations to reduce the chances of ghost markers. In this work, the authors propose retrospective strategies to detect and eliminate ghost markers. The two camera sensors were treated as mathematical points in space. The authors identified the coplanar within limit (CWL) condition as the necessary condition for ghost marker occurrence. A simple ghost marker detection method was proposed based on the model. Ghost marker elimination was achieved through pattern matching: a ghost marker-free reference set was matched with the optical marker set observed by the OTS; unmatched optical markers were eliminated as either ghost markers or misplaced markers. The pattern matching problem was formulated as a constraint satisfaction problem (using pairwise distances as constraints) and solved with an iterative backtracking algorithm. Wildcard markers were introduced to address missing or misplaced markers. An experiment was designed to measure the sensor positions and the limit for the CWL condition. The ghost marker detection and elimination algorithms were verified with samples collected from a five-marker jig and a nine-marker anthropomorphic phantom, rotated with the treatment couch from −60° to +60°. The accuracy of the pattern matching algorithm was further validated with marker patterns from 40 patients who underwent stereotactic body radiotherapy (SBRT). For this purpose, a synthetic optical marker pattern was created for each patient by introducing ghost markers, marker position

  12. Ghost marker detection and elimination in marker-based optical tracking systems for real-time tracking in stereotactic body radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Guanghua, E-mail: yan@ufl.edu; Li, Jonathan; Huang, Yin; Mittauer, Kathryn; Lu, Bo; Liu, Chihray [Department of Radiation Oncology, University of Florida, Gainesville, Florida 32610 (United States)

    2014-10-15

    Purpose: To propose a simple model to explain the origin of ghost markers in marker-based optical tracking systems (OTS) and to develop retrospective strategies to detect and eliminate ghost markers. Methods: In marker-based OTS, ghost markers are virtual markers created due to the cross-talk between the two camera sensors, which can lead to system execution failure or inaccuracy in patient tracking. As a result, the users have to limit the number of markers and avoid certain marker configurations to reduce the chances of ghost markers. In this work, the authors propose retrospective strategies to detect and eliminate ghost markers. The two camera sensors were treated as mathematical points in space. The authors identified the coplanar within limit (CWL) condition as the necessary condition for ghost marker occurrence. A simple ghost marker detection method was proposed based on the model. Ghost marker elimination was achieved through pattern matching: a ghost marker-free reference set was matched with the optical marker set observed by the OTS; unmatched optical markers were eliminated as either ghost markers or misplaced markers. The pattern matching problem was formulated as a constraint satisfaction problem (using pairwise distances as constraints) and solved with an iterative backtracking algorithm. Wildcard markers were introduced to address missing or misplaced markers. An experiment was designed to measure the sensor positions and the limit for the CWL condition. The ghost marker detection and elimination algorithms were verified with samples collected from a five-marker jig and a nine-marker anthropomorphic phantom, rotated with the treatment couch from −60° to +60°. The accuracy of the pattern matching algorithm was further validated with marker patterns from 40 patients who underwent stereotactic body radiotherapy (SBRT). For this purpose, a synthetic optical marker pattern was created for each patient by introducing ghost markers, marker position

  13. Stabilization of Phase of a Sinusoidal Signal Transmitted Over Optical Fiber

    Science.gov (United States)

    DAddario, Larry R.; Trink, Joseph T.

    2010-01-01

    In the process of connecting widely distributed antennas into a coherent array, it is necessary to synchronize the timing of signals at the various locations. This can be accomplished by distributing a common reference signal from a central source, usually over optical fiber. A high-frequency (RF or microwave) tone is a good choice for the reference. One difficulty is that the effective length of the optical fiber changes with temperature and mechanical stress, leading to phase instability in the received tone. This innovation provides a new way to stabilize the phase of the received tone, in spite of variations in the electrical length of the fiber. Stabilization is accomplished by two-way transmission in which part of the received signal is returned to the transmitting end over an identical fiber. The returned signal is detected and used to close an electrical servo loop whose effect is to keep constant the phase of the tone at the receiving end.

  14. LISA Pathfinder E2E performance simulation: optical and self-gravity stability analysis

    Science.gov (United States)

    Brandt, N.; Fichter, W.; Kersten, M.; Lucarelli, S.; Montemurro, F.

    2005-05-01

    End-to-end (E2E) modelling and simulation, i.e. verifying the science performance of LISA Pathfinder (spacecraft and payload), is mandatory in order to minimize mission risks. In this paper, focus is on two particular applications of the E2E performance simulator currently being developed at EADS Astrium GmbH: the opto-dynamical stability and the self-gravity disturbance stability analysis. The E2E models applied here comprise the opto-dynamical modelling of the optical metrology systems (OMS) laser interferometry, the thermo-elastic distortion modelling of the OMS optical elements and the self-gravity disturbance model accounting for structural distortions. Preliminary analysis results are presented in detail, identifying shortcomings of the current LISA technology package (LTP) mounting baseline. As a consequence, the design is now being revised.

  15. LISA Pathfinder E2E performance simulation: optical and self-gravity stability analysis

    International Nuclear Information System (INIS)

    Brandt, N; Fichter, W; Kersten, M; Lucarelli, S; Montemurro, F

    2005-01-01

    End-to-end (E2E) modelling and simulation, i.e. verifying the science performance of LISA Pathfinder (spacecraft and payload), is mandatory in order to minimize mission risks. In this paper, focus is on two particular applications of the E2E performance simulator currently being developed at EADS Astrium GmbH: the opto-dynamical stability and the self-gravity disturbance stability analysis. The E2E models applied here comprise the opto-dynamical modelling of the optical metrology systems (OMS) laser interferometry, the thermo-elastic distortion modelling of the OMS optical elements and the self-gravity disturbance model accounting for structural distortions. Preliminary analysis results are presented in detail, identifying shortcomings of the current LISA technology package (LTP) mounting baseline. As a consequence, the design is now being revised

  16. Monocular distance estimation with optical flow maneuvers and efference copies: a stability-based strategy.

    Science.gov (United States)

    de Croon, Guido C H E

    2016-01-07

    The visual cue of optical flow plays an important role in the navigation of flying insects, and is increasingly studied for use by small flying robots as well. A major problem is that successful optical flow control seems to require distance estimates, while optical flow is known to provide only the ratio of velocity to distance. In this article, a novel, stability-based strategy is proposed for monocular distance estimation, relying on optical flow maneuvers and knowledge of the control inputs (efference copies). It is shown analytically that given a fixed control gain, the stability of a constant divergence control loop only depends on the distance to the approached surface. At close distances, the control loop starts to exhibit self-induced oscillations. The robot can detect these oscillations and hence be aware of the distance to the surface. The proposed stability-based strategy for estimating distances has two main attractive characteristics. First, self-induced oscillations can be detected robustly by the robot and are hardly influenced by wind. Second, the distance can be estimated during a zero divergence maneuver, i.e., around hover. The stability-based strategy is implemented and tested both in simulation and on board a Parrot AR drone 2.0. It is shown that the strategy can be used to: (1) trigger a final approach response during a constant divergence landing with fixed gain, (2) estimate the distance in hover, and (3) estimate distances during an entire landing if the robot uses adaptive gain control to continuously stay on the 'edge of oscillation.'

  17. Identifying and tracking pedestrians based on sensor fusion and motion stability predictions.

    Science.gov (United States)

    Musleh, Basam; García, Fernando; Otamendi, Javier; Armingol, José Maria; de la Escalera, Arturo

    2010-01-01

    The lack of trustworthy sensors makes development of Advanced Driver Assistance System (ADAS) applications a tough task. It is necessary to develop intelligent systems by combining reliable sensors and real-time algorithms to send the proper, accurate messages to the drivers. In this article, an application to detect and predict the movement of pedestrians in order to prevent an imminent collision has been developed and tested under real conditions. The proposed application, first, accurately measures the position of obstacles using a two-sensor hybrid fusion approach: a stereo camera vision system and a laser scanner. Second, it correctly identifies pedestrians using intelligent algorithms based on polylines and pattern recognition related to leg positions (laser subsystem) and dense disparity maps and u-v disparity (vision subsystem). Third, it uses statistical validation gates and confidence regions to track the pedestrian within the detection zones of the sensors and predict their position in the upcoming frames. The intelligent sensor application has been experimentally tested with success while tracking pedestrians that cross and move in zigzag fashion in front of a vehicle.

  18. Identifying and Tracking Pedestrians Based on Sensor Fusion and Motion Stability Predictions

    Directory of Open Access Journals (Sweden)

    Arturo de la Escalera

    2010-08-01

    Full Text Available The lack of trustworthy sensors makes development of Advanced Driver Assistance System (ADAS applications a tough task. It is necessary to develop intelligent systems by combining reliable sensors and real-time algorithms to send the proper, accurate messages to the drivers. In this article, an application to detect and predict the movement of pedestrians in order to prevent an imminent collision has been developed and tested under real conditions. The proposed application, first, accurately measures the position of obstacles using a two-sensor hybrid fusion approach: a stereo camera vision system and a laser scanner. Second, it correctly identifies pedestrians using intelligent algorithms based on polylines and pattern recognition related to leg positions (laser subsystem and dense disparity maps and u-v disparity (vision subsystem. Third, it uses statistical validation gates and confidence regions to track the pedestrian within the detection zones of the sensors and predict their position in the upcoming frames. The intelligent sensor application has been experimentally tested with success while tracking pedestrians that cross and move in zigzag fashion in front of a vehicle.

  19. Identifying and Tracking Pedestrians Based on Sensor Fusion and Motion Stability Predictions

    Science.gov (United States)

    Musleh, Basam; García, Fernando; Otamendi, Javier; Armingol, José Mª; de la Escalera, Arturo

    2010-01-01

    The lack of trustworthy sensors makes development of Advanced Driver Assistance System (ADAS) applications a tough task. It is necessary to develop intelligent systems by combining reliable sensors and real-time algorithms to send the proper, accurate messages to the drivers. In this article, an application to detect and predict the movement of pedestrians in order to prevent an imminent collision has been developed and tested under real conditions. The proposed application, first, accurately measures the position of obstacles using a two-sensor hybrid fusion approach: a stereo camera vision system and a laser scanner. Second, it correctly identifies pedestrians using intelligent algorithms based on polylines and pattern recognition related to leg positions (laser subsystem) and dense disparity maps and u-v disparity (vision subsystem). Third, it uses statistical validation gates and confidence regions to track the pedestrian within the detection zones of the sensors and predict their position in the upcoming frames. The intelligent sensor application has been experimentally tested with success while tracking pedestrians that cross and move in zigzag fashion in front of a vehicle. PMID:22163639

  20. Optical stability under photo-irradiation of urushi films by ion implantation

    International Nuclear Information System (INIS)

    Awazu, Kaoru; Funada, Yoshinori; Kasamori, Masato; Sakamoto, Makoto; Ichikawa, Tachio

    1995-01-01

    Nitrogen ions, argon ions and others were implanted in urushi-coated surfaces by using a simplified ion implantation apparatus, and the optical stability test was carried out by a sunshine weather meter. The rate of remaining luster on urushi-coated surfaces accompanying ultraviolet irradiation showed respective peculiar behavior according to the kinds of the implanted ions, the time of implantation, transparent and black urushi films, and the use of brightener or not. In electron beam irradiation, change hardly occurred. In urushi-coated products, the luster and the properties are maintained for long period, therefore recently, urushi coating has become to be applied to road sign panels and notice boards in addition to lacquer wares and applied fine art products, and the improvement of the optical stability of urushi films has become the subject. In this study, the experimental methods on urushi coating, ion implantation, the optical stability test and measuring method are explained. The changes of urushi film luster, transmittance, haze, lightness, and chromaticity by nitrogen ion implantation are reported. (K.I.)

  1. Ultraviolet radiation-induced modifications of the optical and registration properties of a CR-39 nuclear track detector

    Energy Technology Data Exchange (ETDEWEB)

    Saad, A.F., E-mail: abdallahsaad56@hotmail.com [Physics Department, Faculty of Science, University of Benghazi, Benghazi (Libya); Physics Department, Faculty of Science, Zagazig University, Zagazig (Egypt); Al-Faitory, N.M. [Physics Department, Faculty of Science, University of Benghazi, Benghazi (Libya); Hussein, M. [Physics Department, Faculty of Science, Zagazig University, Zagazig (Egypt); Mohamed, R.A. [Physics Department, Faculty of Science, University of Benghazi, Benghazi (Libya)

    2015-09-15

    The UV–VIS (ultraviolet–visible) spectra and etching characteristics of poly allyl diglycol carbonate (PADC, a form of the CR-39 polymer) detector films after exposure to UV radiation for various times have been studied. Etching experiments were carried out on the UV-exposed CR-39 detectors after alpha particle and fission-fragment irradiation using a {sup 252}Cf source. The bulk and track etch rates were measured using the alpha and fission-fragment track diameters, and the sensitivity and the detection efficiency were also determined. The optical band gap for both indirect and direct transitions was calculated based on the absorption edge of the UV spectra of the pristine and variously UV-exposed detectors. The optical band gap evidently indicates a gradual change in the optical properties of the CR-39 detector that is induced by the UV radiation. This study shows that the UV-exposed CR-39 detectors were demonstrated to be highly sensitive to alpha particles, but proved to be somewhat less sensitive to the fission fragments.

  2. FAST TCP over optical burst switched networks: Modeling and stability analysis

    KAUST Repository

    Shihada, Basem

    2013-04-01

    FAST TCP is important for promoting data-intensive applications since it can cleverly react to both packet loss and delay for detecting network congestion. This paper provides a continuous time model and extensive stability analysis of FAST TCP congestion-control mechanism in bufferless Optical Burst Switched Networks (OBS). The paper first shows that random burst contentions are essential to stabilize the network, but cause throughput degradation in FAST TCP flows when a burst with all the packets from a single round is dropped. Second, it shows that FAST TCP is vulnerable to burst delay and fails to detect network congestion due to the little variation of round-trip time, thus unstable. Finally it shows that introducing extra delays by implementing burst retransmission stabilizes FAST TCP over OBS. The paper proves that FAST TCP is not stable over barebone OBS. However, it is locally, exponentially, and asymptotically stable over OBS with burst retransmission.

  3. Fuzzy - Based Method of Detecting the Enviroment Character for UAV Optical Stabilization

    Directory of Open Access Journals (Sweden)

    David Novak

    2015-01-01

    Full Text Available An optical stabilization of UAV (UAS is a very important part of a structure in their control systems. Not only as a backup stabilization system in a case of IMU failure, but also as a main system, used for stabilization or navigation. In this paper the concept of a system for environment character detection is presented. The system can classify a surrounding environment depending on chosen characteristics. Such system can be used for a better horizon detection due to switching to a correct horizon detection algorithm, which can be used for determining the position of UAV. The system is based on Takagi - Sugeno fuzzy inference system and fuzzy artificial neural networks. An earlier work on this subject was presented last year, but concept of the system was redesigned with a usage of fuzzy artificial neural network for a more precisive outputs and automatic determination of characteristics of fuzzy sets on input.

  4. Region stability analysis and tracking control of memristive recurrent neural network.

    Science.gov (United States)

    Bao, Gang; Zeng, Zhigang; Shen, Yanjun

    2018-02-01

    Memristor is firstly postulated by Leon Chua and realized by Hewlett-Packard (HP) laboratory. Research results show that memristor can be used to simulate the synapses of neurons. This paper presents a class of recurrent neural network with HP memristors. Firstly, it shows that memristive recurrent neural network has more compound dynamics than the traditional recurrent neural network by simulations. Then it derives that n dimensional memristive recurrent neural network is composed of [Formula: see text] sub neural networks which do not have a common equilibrium point. By designing the tracking controller, it can make memristive neural network being convergent to the desired sub neural network. At last, two numerical examples are given to verify the validity of our result. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Effect of gamma irradiation on the etching and optical properties of a newly developed nuclear track detector called (PNADAC) homopolymer

    Energy Technology Data Exchange (ETDEWEB)

    Kalsi, P.C. [Radiochemistry Division, BARC, Trombay, Mumbai 400085 (India)], E-mail: pckalsi@barc.gov.in; Nadkarni, V.S. [Department of Chemistry, Goa University, Goa 403206 (India); Manchanda, V.K. [Radiochemistry Division, BARC, Trombay, Mumbai 400085 (India)

    2008-09-15

    In the present work, we have determined the bulk-etch rates of a newly developed track detector called poly-[N-allyloxycarbonyl diethanolamine-bis allylcarbonate] (PNADAC) homopolymer at different temperatures to deduce its activation energy. The energy of activation is found to be (1.02{+-}0.04) eV. This compares very well with the values of activation energy reported in the literature for the most commonly used nuclear track detectors. The effects of gamma irradiation on this new detector in the dose range of 4.7-14.5 Mrad have also been studied using UV-visible spectroscopic technique. The optical band gaps of the unirradiated and the gamma-irradiated detectors determined from the UV-visible spectra were found to decrease with the increase in gamma dose. These results have been explained on the basis of scission of the detector due to gamma irradiation.

  6. Tracking the Genetic Stability of a Honey Bee (Hymenoptera: Apidae) Breeding Program With Genetic Markers.

    Science.gov (United States)

    Bourgeois, Lelania; Beaman, Lorraine

    2017-08-01

    A genetic stock identification (GSI) assay was developed in 2008 to distinguish Russian honey bees from other honey bee stocks that are commercially produced in the United States. Probability of assignment (POA) values have been collected and maintained since the stock release in 2008 to the Russian Honey Bee Breeders Association. These data were used to assess stability of the breeding program and the diversity levels of the contemporary breeding stock through comparison of POA values and genetic diversity parameters from the initial release to current values. POA values fluctuated throughout 2010-2016, but have recovered to statistically similar levels in 2016 (POA(2010) = 0.82, POA(2016) = 0.74; P = 0.33). Genetic diversity parameters (i.e., allelic richness and gene diversity) in 2016 also remained at similar levels when compared to those in 2010. Estimates of genetic structure revealed stability (FST(2009/2016) = 0.0058) with a small increase in the estimate of the inbreeding coefficient (FIS(2010) = 0.078, FIS(2016) = 0.149). The relationship among breeding lines, based on genetic distance measurement, was similar in 2008 and 2016 populations, but with increased homogeneity among lines (i.e., decreased genetic distance). This was expected based on the closed breeding system used for Russian honey bees. The successful application of the GSI assay in a commercial breeding program demonstrates the utility and stability of such technology to contribute to and monitor the genetic integrity of a breeding stock of an insect species. Published by Oxford University Press on behalf of Entomological Society of America 2017. This work is written by US Government employees and is in the public domain in the US.

  7. Design of a stabilized, compact gimbal for space-based free space optical communications (FSOC)

    Science.gov (United States)

    Cline, A.; Shubert, P.; McNally, J.; Jacka, N.; Pierson, R.

    2017-02-01

    Data transmits via optical communications through fibers at 10's of Terabits per second. Given the recent rapid explosion for bandwidth and competing demand for radio frequency (RF) spectrum allocations among differing interests, the need for space-based free space optical communications (FSOC) systems is ever increasing. FSOC systems offer advantages of higher data rates, smaller size and weight, narrower beam divergence, and lower power than RF systems. Lightweight, small form factor, and high performance two-axis gimbals are of strong interest for satellite FSOC applications. Small gimbal and optical terminal designs are important for widespread implementation of optical communications systems; in particular, for satellite-to-satellite crosslinks where the advantages of more secure communications links (Lower Probability of Intercept (LPI)/Lower Probability of Detect (LPD)) are very important. We developed design concepts for a small gimbal focusing on the use of commercial off-the-shelf (COTS) subsystems to establish their feasible implementation against the pointing stabilization, size, weight and power (SWaP), and performance challenges. The design drivers for the gimbal were weight, the elevation and azimuth field of regards, the form factor envelope (1U CubeSats), 100 μrad pointing accuracy, and 10 degrees per second slew capability. Innovations required in this development included a continuous fiber passed through an Azimuth Fiber Wrap and Elevation Fiber Wrap, overcoming typical mechanical and stress related limitations encountered with fiber optic cable wraps. In this presentation, we describe the configuration trades and design of such a gimbal.

  8. A study of the effect of gamma and laser irradiation on the thermal, optical and structural properties of CR-39 nuclear track detector

    Science.gov (United States)

    Nouh, S. A.; Atta, M. R.; El-Melleegy, W. M.

    2004-08-01

    A comparative study of the effect of gamma and laser irradiation on the thermal, optical and structural properties of the CR-39 diglycol carbonate solid state nuclear track detector has been carried out. Samples from CR-39 polymer were classified into two main groups: the first group was irradiated by gamma rays with doses at levels between 20 and 300 kGy, whereas the second group was exposed to infrared laser radiation with energy fluences at levels between 0.71 and 8.53 J/cm(2). Non-isothermal studies were carried out using thermogravimetry, differential thermogravimetry and differential thermal analysis to obtain activation energy of decomposition and transition temperatures for the non-irradiated and all irradiated CR-39 samples. In addition, optical and structural property studies were performed on non-irradiated and irradiated CR-39 samples using refractive index and X-ray diffraction measurements. Variation in the onset temperature of decomposition T-o, activation energy of decomposition E-a, melting temperature T-m, refractive index n and the mass fraction of the amorphous phase after gamma and laser irradiation were studied. It was found that many changes in the thermal, optical and structural properties of the CR-39 polymer could be produced by gamma irradiation via degradation and cross-linking mechanisms. Also, the gamma dose has an advantage of increasing the correlation between thermal stability of the CR-39 polymer and bond formation created by the ionizing effect of gamma radiation. On the other hand, higher laser-energy fluences in the range 4.27-8.53 J/cm(2) decrease the melting temperature of the CR-39 polymer and this is most suitable for applications requiring molding of the polymer at lower temperatures.

  9. Optical power of VCSELs stabilized to 35 ppm/°C without a TEC

    Science.gov (United States)

    Downing, John

    2015-03-01

    This paper reports a method and system comprising a light source, an electronic method, and a calibration procedure for stabilizing the optical power of vertical-cavity surface-emitting lasers (VCSELs) and laser diodes (LDs) without the use thermoelectric coolers (TECs). The system eliminates the needs for custom interference coatings, polarization adjustments, and the exact alignment required by the optical method reported in 2013 [1]. It can precisely compensate for the effects of temperature and wavelength drift on photodiode responsivity as well as changes in VCSEL beam quality and polarization angle over a 50°C temperature range. Data obtained from light sources built with single-mode polarization-locked VCSELs demonstrate that 30 ppm/°C stability can be readily obtained. The system has advantages over TECstabilized laser modules that include: 1) 90% lower relative RMS optical power and temperature sensitivity, 2) a five-fold enhancement of wall-plug efficiency, 3) less component testing and sorting, 4) lower manufacturing costs, and 5) automated calibration in batches at time of manufacture is practical. The system is ideally suited for battery-powered environmental and in-home medical monitoring applications.

  10. Real-time correction by optical tracking with integrated geometric distortion correction for reducing motion artifacts in functional MRI.

    Science.gov (United States)

    Rotenberg, David; Chiew, Mark; Ranieri, Shawn; Tam, Fred; Chopra, Rajiv; Graham, Simon J

    2013-03-01

    Head motion artifacts are a major problem in functional MRI that limit its use in neuroscience research and clinical settings. Real-time scan-plane correction by optical tracking has been shown to correct slice misalignment and nonlinear spin-history artifacts; however, residual artifacts due to dynamic magnetic field nonuniformity may remain in the data. A recently developed correction technique, Phase Labeling for Additional Coordinate Encoding, can correct for absolute geometric distortion using only the complex image data from two echo planar images with slightly shifted k-space trajectories. An approach is presented that integrates Phase Labeling for Additional Coordinate Encoding into a real-time scan-plane update system by optical tracking, applied to a tissue-equivalent phantom undergoing complex motion and an functional MRI finger tapping experiment with overt head motion to induce dynamic field nonuniformity. Experiments suggest that such integrated volume-by-volume corrections are very effective at artifact suppression, with potential to expand functional MRI applications. Copyright © 2012 Wiley Periodicals, Inc.

  11. Label-free tracking of single extracellular vesicles in a nano-fluidic optical fiber (Conference Presentation)

    Science.gov (United States)

    van der Pol, Edwin; Weidlich, Stefan; Lahini, Yoav; Coumans, Frank A. W.; Sturk, Auguste; Nieuwland, Rienk; Schmidt, Markus A.; Faez, Sanli; van Leeuwen, Ton G.

    2016-03-01

    Background: Extracellular vesicles, such as exosomes, are abundantly present in human body fluids. Since the size, concentration and composition of these vesicles change during disease, vesicles have promising clinical applications, including cancer diagnosis. However, since ~70% of the vesicles have a diameter vesicles remains challenging. Thus far, vesicles vesicles to be adhered to a surface. Consequently, the majority of vesicles have never been studied in their physiological environment. We present a novel label-free optical technique to track single vesicles vesicles were contained within a single-mode light-guiding silica fiber containing a 600 nm nano-fluidic channel. Light from a diode laser (660 nm wavelength) was coupled to the fiber, resulting in a strongly confined optical mode in the nano-fluidic channel, which continuously illuminated the freely diffusing vesicles inside the channel. The elastic light scattering from the vesicles, in the direction orthogonal to the fiber axis, was collected using a microscope objective (NA=0.95) and imaged with a home-built microscope. Results: We have tracked single urinary vesicles as small as 35 nm by elastic light scattering. Please note that vesicles are low-refractive index (nvesicles vesicle-based clinical applications.

  12. Femtosecond stabilization of optical fiber links based on RF power detection

    International Nuclear Information System (INIS)

    Lamb, Thorsten

    2011-01-01

    X-ray light sources like the free electron laser FLASH in Hamburg or the future XFEL generate light pulses with durations in the order of a few ten femtoseconds. To fulfill the requirements for the synchronisation of various components on this timescale, optical synchronisation systems are already successfully used. In this diploma thesis a novel photodiode-based, detection principle for the measurement of drifts in the optical links of such a synchronisation system is developed. The detection principle is nearly drift-free and highly robust. It is demonstrated that the long term stability of the assembled detector over 33 h is below 5 fs (peak to peak) at a standard deviation of 0.86 fs. Furthermore, an active stabilisation of a fibre link using this detector is successfully achieved. (orig.)

  13. Optical Properties And Thermal Stability Of Single-Point Diamond-Machined Aluminum Alloys

    Science.gov (United States)

    Ogloza, A. A.; Decker, D. L.; Archibald, P. C.; O'Connor, D. A.; Bueltmann, E. R.

    1989-01-01

    This paper presents the results of diamond-turned surfaces of a wide range of aluminum alloys. The alloys machined included a sand-cast A201 alloy manufactured by Specialty Aluminum Inc., conventionally extruded plate alloys 2024, 3003, 5052, 6061, 7075, and for comparison as a best and worst case possible a high-purity aluminum single crystal, and tooling plate. The surfaces were obtained by diamond single-point machining using an interferometrically controlled two-axis, air-bearing lathe. The effect of tool-rake angle and machining fluid on surface quality is examined. Surface characterization was performed by Nomarski microscopy and noncontact optical surface profilometry. The optical properties measured included absolute reflectance at 3.8 μm, total integrated scatter at 752.5 nm, and bidirectional reflection distribution function measurements at 632.8 nm. The dimensional stability of the aluminum alloys subject to thermal cycling is examined.

  14. A stabilized optical frequency comb based on an Er-doped fiber femtosecond laser

    Science.gov (United States)

    Xia, Chuanqing; Wu, Tengfei; Zhao, Chunbo; Xing, Shuai

    2018-03-01

    An optical frequency comb based on a 250 MHz home-made Er-doped fiber femtosecond laser is presented in this paper. The Er-doped fiber laser has a ring cavity and operates mode-locked in femtosecond regime with the technique of nonlinear polarization rotation. The pulse duration is 118 fs and the spectral width is 30 nm. A part of the femtosecond laser is amplified in Er-doped fiber amplifier before propagating through a piece of highly nonlinear fiber for expanding the spectrum. The carrier-envelope offset frequency of the comb which has a signal-to-noise ratio more than 35 dB is extracted by means of f-2f beating. It demonstrates that both carrier-envelope offset frequency and repetition frequency keep phase locked to a Rubidium atomic clock simultaneously for 2 hours. The frequency stabilized fiber combs will be increasingly applied in optical metrology, attosecond pulse generation, and absolute distance measurement.

  15. Polarization tracking system for free-space optical communication, including quantum communication

    Science.gov (United States)

    Nordholt, Jane Elizabeth; Newell, Raymond Thorson; Peterson, Charles Glen; Hughes, Richard John

    2018-01-09

    Quantum communication transmitters include beacon lasers that transmit a beacon optical signal in a predetermined state of polarization such as one of the states of polarization of a quantum communication basis. Changes in the beacon polarization are detected at a receiver, and a retarder is adjusted so that the states of polarization in a received quantum communication optical signal are matched to basis polarizations. The beacon and QC signals can be at different wavelengths so that the beacon does not interfere with detection and decoding of the QC optical signal.

  16. Rapid feedback control and stabilization of an optical tweezers with a budget microcontroller

    International Nuclear Information System (INIS)

    Nino, Daniel; Wang, Haowei; N Milstein, Joshua

    2014-01-01

    Laboratories ranging the scientific disciplines employ feedback control to regulate variables within their experiments, from the flow of liquids within a microfluidic device to the temperature within a cell incubator. We have built an inexpensive, yet fast and rapidly deployed, feedback control system that is straightforward and flexible to implement from a commercially available Arduino Due microcontroller. This is in comparison with the complex, time-consuming and often expensive electronics that are commonly implemented. As an example of its utility, we apply our feedback controller to the task of stabilizing the main trapping laser of an optical tweezers. The feedback controller, which is inexpensive yet fast and rapidly deployed, was implemented from hacking an open source Arduino Due microcontroller. Our microcontroller based feedback system can stabilize the laser intensity to a few tenths of a per cent at 200 kHz, which is an order of magnitude better than the laser's base specifications, illustrating the utility of these devices. (paper)

  17. Rapid feedback control and stabilization of an optical tweezers with a budget microcontroller

    Science.gov (United States)

    Nino, Daniel; Wang, Haowei; Milstein, Joshua N.

    2014-09-01

    Laboratories ranging the scientific disciplines employ feedback control to regulate variables within their experiments, from the flow of liquids within a microfluidic device to the temperature within a cell incubator. We have built an inexpensive, yet fast and rapidly deployed, feedback control system that is straightforward and flexible to implement from a commercially available Arduino Due microcontroller. This is in comparison with the complex, time-consuming and often expensive electronics that are commonly implemented. As an example of its utility, we apply our feedback controller to the task of stabilizing the main trapping laser of an optical tweezers. The feedback controller, which is inexpensive yet fast and rapidly deployed, was implemented from hacking an open source Arduino Due microcontroller. Our microcontroller based feedback system can stabilize the laser intensity to a few tenths of a per cent at 200 kHz, which is an order of magnitude better than the laser's base specifications, illustrating the utility of these devices.

  18. Edge-emitting lasers based on coupled large optical cavity with high beam stability

    Science.gov (United States)

    Serin, A.; Gordeev, N.; Payusov, A.; Shernyakov, Y.; Kalyuzhnyy, y.; Mintairov, S.; Maximov, M.

    2017-11-01

    In this paper we present a study on temperature and current stability of far-field patterns of lasers based on the coupled large optical cavity (CLOC) concept. Previously it has been shown that the CLOC structures allows effective suppressing of high-order mode lasing in broadened waveguides. For the first time we report on transverse single-mode emission from the CLOC lasers with 4.8 μm thick waveguide. Using broadened waveguide allowed us to reduce the divergence of the far-field patterns down to 14° in continuous-wave (CW) regime. Far-field patterns proved to be insensitive to current and temperature changes.

  19. Photochemical stability of nonlinear optical chromophores in polymeric and crystalline materials

    International Nuclear Information System (INIS)

    Rezzonico, Daniele; Kwon, Seong-Ji; Figi, Harry; Kwon, O-Pil; Jazbinsek, Mojca; Guenter, Peter

    2008-01-01

    We compare the photochemical stability of the nonlinear optical chromophore configurationally locked polyene 2-(3-[2-(4-dimethylaminophenyl)vinyl]-5,5-dimethylcyclohex-2-enylidene) malononitrile (DAT2) embedded in a polymeric matrix and in a single-crystalline configuration. The results show that, under resonant light excitations, the polymeric compound degrades through an indirect process, while the DAT2 crystal follows a slow direct process. We show that chromophores in a crystalline environment exhibit three orders of magnitude better photostability as compared to guest-host polymer composites

  20. Stability of dark solitons in a Bose-Einstein condensate trapped in an optical lattice

    International Nuclear Information System (INIS)

    Kevrekidis, P. G.; Carretero-Gonzalez, R.; Theocharis, G.; Frantzeskakis, D. J.; Malomed, B. A.

    2003-01-01

    We investigate the stability of dark solitons (DSs) in an effectively one-dimensional Bose-Einstein condensate in the presence of the magnetic parabolic trap and an optical lattice (OL). The analysis is based on both the full Gross-Pitaevskii equation and its tight-binding approximation counterpart (discrete nonlinear Schroedinger equation). We find that DSs are subject to weak instabilities with an onset of instability mainly governed by the period and amplitude of the OL. The instability, if present, sets in at large times and it is characterized by quasiperiodic oscillations of the DS about the minimum of the parabolic trap

  1. Photochemical stability of nonlinear optical chromophores in polymeric and crystalline materials.

    Science.gov (United States)

    Rezzonico, Daniele; Kwon, Seong-Ji; Figi, Harry; Kwon, O-Pil; Jazbinsek, Mojca; Günter, Peter

    2008-03-28

    We compare the photochemical stability of the nonlinear optical chromophore configurationally locked polyene 2-{3-[2-(4-dimethylaminophenyl)vinyl]-5,5-dimethylcyclohex-2-enylidene} malononitrile (DAT2) embedded in a polymeric matrix and in a single-crystalline configuration. The results show that, under resonant light excitations, the polymeric compound degrades through an indirect process, while the DAT2 crystal follows a slow direct process. We show that chromophores in a crystalline environment exhibit three orders of magnitude better photostability as compared to guest-host polymer composites.

  2. Optical tracking of spherical micro-objects in spatially periodic interference fields

    Czech Academy of Sciences Publication Activity Database

    Čižmár, Tomáš; Zemánek, Pavel

    2007-01-01

    Roč. 15, č. 5 (2007), s. 2262-2272 ISSN 1094-4087 R&D Projects: GA MŠk(CZ) LC06007 Grant - others:EC 6FP(XE) ATOM3D No. 508952 Institutional research plan: CEZ:AV0Z20650511 Keywords : image analysis * optical confinement and manipulation * total internal reflection * scattering * particles Subject RIV: BH - Optics, Masers, Lasers Impact factor: 3.709, year: 2007

  3. High-Speed Microscale Optical Tracking Using Digital Frequency-Domain Multiplexing

    OpenAIRE

    MacLachlan, Robert A.; Riviere, Cameron N.

    2009-01-01

    Position-sensitive detectors (PSDs), or lateral-effect photodiodes, are commonly used for high-speed, high-resolution optical position measurement. This paper describes the instrument design for multidimensional position and orientation measurement based on the simultaneous position measurement of multiple modulated sources using frequency-domain-multiplexed (FDM) PSDs. The important advantages of this optical configuration in comparison with laser/mirror combinations are that it has a large ...

  4. THE DETERMINATION OF A CRITICAL VALUE FOR DYNAMIC STABILITY OF SEMICONDUCTOR LASER DIODE WITH EXTERNAL OPTICAL FEEDBACK

    Directory of Open Access Journals (Sweden)

    Remzi YILDIRIM

    1998-01-01

    Full Text Available In this study, dynamic stability analysis of semiconductor laser diodes with external optical feedback has been realized. In the analysis the frequency response of the transfer function of laser diode H jw( , the transfer m function of laser diode with external optical feedback TF jw( , and optical feedback transfer function m K jw( obtained from small signal equations has been m accomplished using Nyquist stability analysis in complex domain. The effect of optical feedback on the stability of the system has been introduced and to bring the laser diode to stable condition the working critical boundary range of dampig frequency and reflection power constant (R has been determined. In the study the reflection power has been taken as ( .

  5. Dynamic Probing of Nanoparticle Stability In Vivo: A Liposomal Model Assessed Using In Situ Microdialysis and Optical Imaging

    Directory of Open Access Journals (Sweden)

    Chien-Chung Jeng

    2011-01-01

    Full Text Available Nanoparticle-mediated drug delivery and controlled release has been a vigorous research area in contemporary nanomedicine. The in vivo stability of nanoparticle delivered on site is a prerequisite for the design of drug-controlled release by any means. In this study, the first methodology comprised of microdialysis and optical imaging to assess the liposome stability in vivo is reported. Macroscopically, we demonstrated the DPPG liposomes with negative surface charge fast accumulated in the rat liver upon their i.v. administration using optical imaging. Microscopically, the concurrent analysis of fluorescent molecules leaching from the liposomes, in situ sampled using microdialysis probe, provides the dynamic information of stability of DPPG liposomes locus in quo. The current combination of in situ microdialysis and optical imaging possesses a great potential for use as a platform technology to evaluate the nanoparticle stability and the bioavailability of drug payload released on targeted site in vivo.

  6. CSSTag: Optical Nanoscale Radar and Particle Tracking for In-Body and Microfluidic Systems with Vibrating Graphene and Resonance Energy Transfer

    OpenAIRE

    Gulbahar, Burhan; Memisoglu, Gorkem

    2017-01-01

    Single particle tracking systems monitor cellular processes with great accuracy in nano-biological systems. The emissions of the fluorescent molecules are detected with cameras or photodetectors. However, state-of-the-art imaging systems have challenges in the detection capability, collection and analysis of imaging data, penetration depth and complicated set-ups. In this article, a \\textit{signaling based nanoscale acousto-optic radar and microfluidic particle tracking system} is proposed ba...

  7. Polymer-Stabilized Micropixelated Liquid Crystals with Tunable Optical Properties Fabricated by Double Templating.

    Science.gov (United States)

    Sasaki, Yuji; Ueda, Motoshi; Le, Khoa V; Amano, Reo; Sakane, Shin; Fujii, Shuji; Araoka, Fumito; Orihara, Hiroshi

    2017-10-01

    Self-organized nano- and microstructures of soft materials are attracting considerable attention because most of them are stimuli-responsive due to their soft nature. In this regard, topological defects in liquid crystals (LCs) are promising not only for self-assembling colloids and molecules but also for electro-optical applications such as optical vortex generation. However, there are currently few bottom-up methods for patterning a large number of defects periodically over a large area. It would be highly desirable to develop more effective techniques for high-throughput and low-cost fabrication. Here, a micropixelated LC structure consisting of a square array of topological defects is stabilized by photopolymerization. A polymer network is formed on the structure of a self-organized template of a nematic liquid crystal (NLC), and this in turn imprints other nonpolymerizable NLC molecules, which maintains their responses to electric field and temperature. Photocuring of specific local regions is used to create a designable template for the reproducible self-organization of defects. Moreover, a highly diluted polymer network (≈0.1 wt% monomer) exhibits instant on-off switching of the patterns. Beyond the mere stabilization of patterns, these results demonstrate that the incorporation of self-organized NLC patterns offers some unique and unconventional applications for anisotropic polymer networks. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. LHC Optics Measurement with Proton Tracks Detected by the Roman Pots of the TOTEM Experiment

    CERN Document Server

    INSPIRE-00062364; Aspell, P; Atanassov, I; Avati, V; Baechler, J; Berardi, V; Berretti, M; Bossini, E; Bottigli, U; Bozzo, M; Brücken, E; Buzzo, A; Cafagna, F S; Catanesi, M G; Covault, C; Csanád, M; Csörgö, T; Deile, M; Doubek, M; Eggert, K; Eremin, V; Ferro, F; Fiergolski, A; Garcia, F; Georgiev, V; Giani, S; Grzanka, L; Hammerbauer, J; Heino, J; Hilden, T; Karev, A; Kašpar, J; Kopal, J; Kundrát, V; Lami, S; Latino, G; Lauhakangas, R; Leszko, T; Lippmaa, E; Lippmaa, J; Lokajíček, M V; Losurdo, L; Lo Vetere, M; Lucas Rodríguez, F; Macrí, M; Mäki, T; Mercadante, A; Minafra, N; Minutoli, S; Nemes, F; Niewiadomski, H; Oliveri, E; Oljemark, F; Orava, R; Oriunno, M; Österberg, K; Palazzi, P; Peroutka, Z; Procházka, J; Quinto, M; Radermacher, E; Radicioni, E; Ravotti, F; Robutti, E; Ropelewski, L; Ruggiero, G; Saarikko, H; Scribano, A; Smajek, J; Snoeys, W; Sziklai, J; Taylor, C; Turini, N; Vacek, V; Welti, J; Whitmore, J; Wyszkowski, P; Zielinski, K

    2014-10-28

    Precise knowledge of the beam optics at the LHC is crucial to fulfil the physics goals of the TOTEM experiment, where the kinematics of the scattered protons is reconstructed with the near-beam telescopes -- so-called Roman Pots (RP). Before being detected, the protons' trajectories are influenced by the magnetic fields of the accelerator lattice. Thus precise understanding of the proton transport is of key importance for the experiment. A novel method of optics evaluation is proposed which exploits kinematical distributions of elastically scattered protons observed in the RPs. Theoretical predictions, as well as Monte Carlo studies, show that the residual uncertainty of this optics estimation method is smaller than 0.25 percent.

  9. LHC Optics Measurement with Proton Tracks Detected by the Roman Pots of the TOTEM Experiment

    CERN Document Server

    Nemes, Frigyes J

    2015-01-01

    Precise knowledge of the beam optics at the LHC is crucial to fulfill the physics goals of the TOTEM experiment, where the kinematics of the scattered protons is reconstructed with the near-beam telescopes – so-called Roman Pots (RP). Before being detected, the protons’ trajectories are influenced by the magnetic fields of the accelerator lattice. Thus precise understanding of the proton transport is of key importance for the experiment. A novel method of optics evaluation is proposed which exploits kinematical distributions of elastically scattered protons observed in the RPs. Theoretical predictions, as well as Monte Carlo studies, show that the residual uncertainty of the optics estimation method is smaller than 2.5 permille.

  10. Electron beam position stabilization with a piezo-electric optical correction system

    CERN Document Server

    Averett, T; McKeown, R D; Pitt, M

    1999-01-01

    A piezo-electrically controlled optical correction system was successfully used to reduce the helicity-correlated pulse-to-pulse position differences of a laser spot to better than +-100 nm at a pulse rate of 600 Hz. Using a simple feedback algorithm, average position differences of DELTA x-bar=-3.5+-4.2 nm and DELTA y-bar=2.6+-6.6 nm were obtained over a 6 h period. This optical correction system was successfully used in the polarized electron source at the Bates Linear Accelerator Center to stabilize the position of the electron beam during the recent SAMPLE experiment. Because this experiment measures a parity violating signal at the 10 sup - sup 6 level, it is sensitive to systematic effects which are correlated with the helicity of the incident electrons. One potentially large systematic effect is the helicity-correlated motion of the incident electron beam. By using this optical correction system, electron beam position differences at the location of the experiment were routinely kept well below +-100 n...

  11. Virtual velocity loop based on MEMS accelerometers for optical stabilization control system

    Science.gov (United States)

    Ren, Wei; Deng, Chao; Mao, Yao; Ren, Ge

    2017-08-01

    In the optical stabilization control system (OSCS) control system based on a charge-coupled device (CCD), stabilization performance of the line-of-sight is severely limited by the mechanical resonance and the low sampling rate of the CCD. An approach to improve the stabilization performance of the OSCS control system with load restriction based on three loops, including an acceleration loop, a virtual velocity loop, and a position loop, by using MEMS accelerometers and a CCD is proposed. The velocity signal is obtained by accelerators instead of gyro sensors. Its advantages are low power, low cost, small size, and wide measuring range. A detailed analysis is provided to show how to design the virtual velocity loop and correct virtual velocity loop drift. Experimental results show that the proposed multiloop feedback control method with virtual velocity loop in which the disturbance suppression performance is better than that of the dual loop control with only an acceleration loop and a position loop at low frequency.

  12. Improving thermal stability of a resonator fiber optic gyro employing a polarizing resonator.

    Science.gov (United States)

    Yu, Xuhui; Ma, Huilian; Jin, Zhonghe

    2013-01-14

    To improve the thermal stability of a resonator fiber optic gyro (R-FOG), a transmission-type polarizing resonator by inserting two in-line polarizers in a polarization-maintaining fiber resonator with twin 90° polarization-axis rotated splices is proposed and experimentally demonstrated. The in-line polarizers attenuate the unwanted resonance by introducing high loss for the unwanted eigenstates of polarization in the resonator. The desired resonance in the resonator can keep excellent stability in a wide temperature range, thus the temperature-related polarization error in the R-FOG is dramatically suppressed. Both our numerical simulation and experimental verification are carried out, which for the first time to our best knowledge demonstrate that the open-loop output of the R-FOG is insensitive to environmental temperature variations. A bias stability below 2°/h in the temperature range of 36.2°C to 33°C is successfully demonstrated.

  13. Effects of gamma irradiation on optical properties of polycarbonate: different formulations with commercial stabilizers

    International Nuclear Information System (INIS)

    Ferreira, Carlas C.; Aquino, Katia Aparecida da S.; Araujo, Elmo S.

    2009-01-01

    Medical plastics are in general sterilized by gamma irradiation in doses of 25 kGy. However, this process often causes discoloration of the product due the formation of color centers during the irradiation. In particular, polycarbonate (PC), a transparent thermoplastic, when gamma-irradiated undergoes main chain scissions with consequent yellowness. This discoloration is attributed the formation of macroradicals type phenoxyl and phenyl produced by irradiation process. PC was prepared in formulations containing different stabilizers in order to investigate its optical properties (transmittance and yellowness index) changed by irradiation process. Among the stabilizers tested, a new commercial stabilizer (high performance phosphite) has presented good results concerning to reduction of the yellowness in irradiated specimen tests. Transmittance (at 420 nm) of irradiated samples at doses of 25 kGy decreases to ∼ 45% of non-irradiated sample value, immediately to the irradiation process. Nevertheless, this transmittance is increased to values of ∼ 70% of non-irradiated sample, after 60 hours under heating into oven (45 deg C). (author)

  14. Low-Complexity Tracking of Laser and Nonlinear Phase Noise in WDM Optical Fiber Systems

    DEFF Research Database (Denmark)

    Yankov, Metodi Plamenov; Fehenberger, Tobias; Barletta, Luca

    2015-01-01

    In this paper, the wavelength division multiplexed (WDM) fiber optic channel is considered. It is shown that for ideal distributed Raman amplification (IDRA), the Wiener process model is suitable for the non-linear phase noise due to cross phase modulation from neighboring channels. Based...

  15. Study of the optical properties and the carbonaceous clusters in DAM-ADC solid state nuclear track detectors

    Science.gov (United States)

    Rammah, Y. S.; Abdalla, A. M.

    2017-12-01

    The optical properties of DAM-ADC solid state nuclear track detectors (SSNTDs) were investigated. Samples of DAM-ADC detector were irradiated at room temperature with gamma doses in the range of 100-500 kGy using 1.25 MeV 60Co source of dose rate 4 kGy/h. The optical characterization of these detectors have been studied through the measurements of UV-visible absorption spectra of blank and γ- irradiated samples. The optical energy band gaps, Eg for the detectors were obtained from the direct and the indirect allowed transitions in K-space using two methods (Tauc's model and absorption spectrum fitting (ASF) method). The absorbance of DAM-ADC detector was found to increase with increasing of the gamma absorbed dose. The width of the tail of localized states in the band gap, Eu was evaluated with the Urbach's method. The number of carbon atoms per conjugated length (N), the number of carbon atoms per cluster (M), and refractive index (n) for the present samples were determined. Both of the direct and the indirect band gaps of DAM-ADC detector decrease with increasing of the gamma absorbed dose. Urbach's energy decreased significantly for the detector. An increase in N, M, and n with increasing of the gamma absorbed dose was noticed. Results shed light on the effect of gamma irradiations of DAM-ADC SSNTDs to suitable industrial applications and to modify the optical properties through gamma-induced modifications of the polymer structure.

  16. The influence of image sensor irradiation damage on the tracking and pointing accuracy of optical communication system

    Science.gov (United States)

    Li, Xiaoliang; Luo, Lei; Li, Pengwei; Yu, Qingkui

    2018-03-01

    The image sensor in satellite optical communication system may generate noise due to space irradiation damage, leading to deviation for the determination of the light spot centroid. Based on the irradiation test data of CMOS devices, simulated defect spots in different sizes have been used for calculating the centroid deviation value by grey-level centroid algorithm. The impact on tracking & pointing accuracy of the system has been analyzed. The results show that both the amount and the position of irradiation-induced defect pixels contribute to spot centroid deviation. And the larger spot has less deviation. At last, considering the space radiation damage, suggestions are made for the constraints of spot size selection.

  17. Optical eye tracking system for real-time noninvasive tumor localization in external beam radiotherapy

    International Nuclear Information System (INIS)

    Via, Riccardo; Fassi, Aurora; Fattori, Giovanni; Fontana, Giulia; Pella, Andrea; Tagaste, Barbara; Ciocca, Mario; Riboldi, Marco; Baroni, Guido; Orecchia, Roberto

    2015-01-01

    Purpose: External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Methods: Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Results: Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. Conclusions: A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring

  18. Optical eye tracking system for real-time noninvasive tumor localization in external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Via, Riccardo, E-mail: riccardo.via@polimi.it; Fassi, Aurora; Fattori, Giovanni [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano 20133 (Italy); Fontana, Giulia; Pella, Andrea; Tagaste, Barbara; Ciocca, Mario [CNAO Centro Nazionale di Adroterapia Oncologica, Pavia 27100 (Italy); Riboldi, Marco; Baroni, Guido [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano 20133, Italy and CNAO Centro Nazionale di Adroterapia Oncologica, Pavia 27100 (Italy); Orecchia, Roberto [CNAO Centro Nazionale di Adroterapia Oncologica, Pavia 27100, Italy and European Institute of Oncology, Milano 20141 (Italy)

    2015-05-15

    Purpose: External beam radiotherapy currently represents an important therapeutic strategy for the treatment of intraocular tumors. Accurate target localization and efficient compensation of involuntary eye movements are crucial to avoid deviations in dose distribution with respect to the treatment plan. This paper describes an eye tracking system (ETS) based on noninvasive infrared video imaging. The system was designed for capturing the tridimensional (3D) ocular motion and provides an on-line estimation of intraocular lesions position based on a priori knowledge coming from volumetric imaging. Methods: Eye tracking is performed by localizing cornea and pupil centers on stereo images captured by two calibrated video cameras, exploiting eye reflections produced by infrared illumination. Additionally, torsional eye movements are detected by template matching in the iris region of eye images. This information allows estimating the 3D position and orientation of the eye by means of an eye local reference system. By combining ETS measurements with volumetric imaging for treatment planning [computed tomography (CT) and magnetic resonance (MR)], one is able to map the position of the lesion to be treated in local eye coordinates, thus enabling real-time tumor referencing during treatment setup and irradiation. Experimental tests on an eye phantom and seven healthy subjects were performed to assess ETS tracking accuracy. Results: Measurements on phantom showed an overall median accuracy within 0.16 mm and 0.40° for translations and rotations, respectively. Torsional movements were affected by 0.28° median uncertainty. On healthy subjects, the gaze direction error ranged between 0.19° and 0.82° at a median working distance of 29 cm. The median processing time of the eye tracking algorithm was 18.60 ms, thus allowing eye monitoring up to 50 Hz. Conclusions: A noninvasive ETS prototype was designed to perform real-time target localization and eye movement monitoring

  19. TRACK--A new method for the evaluation of low-level extinction coefficient in optical films.

    Science.gov (United States)

    Vernhes, R; Martinu, L

    2015-11-02

    We develop a rigorous methodology named TRACK based on the collection of multi-angle spectrophotometric transmission and reflection data in order to assess the extinction coefficient of quasi-transparent optical films. The accuracy of extinction coefficient values obtained by this method is not affected by sample non-idealities (thickness non-uniformity, refractive index inhomogeneities, anisotropy, interfaces, etc.) and therefore a simple two-layer (substrate/film) optical model can be used. The method requires the acquisition of transmission and reflection data at two angles of incidence: 10° and 65° in p polarization. Data acquired at 10° provide information about the film thickness and the refractive index, while data collected at 65° are used for absorption evaluation and extinction coefficient computation. We test this method on three types of samples: (i) a CR-39 plastic substrate coated with a thick protective coating; (ii) the same substrate coated with a thin TiO(2) film; (iii) and a thick Si(3)N(4) film deposited on Gorilla glass that presents thickness non-uniformity and refractive index gradient non-idealities. We also compare absorption and extinction coefficient values obtained at 410 and 550 nm by both TRACK and Laser Induced Deflection techniques in the case of a 1 micron thick TiO(2) coating. Both methods display consistent extinction coefficient values in the 10(-4) and 10(-5) ranges at 410 and 550 nm, respectively, which proves the validity of the methodology and provides an estimate of its accuracy limit.

  20. An Ice Track Equipped with Optical Sensors for Determining the Influence of Experimental Conditions on the Sliding Velocity

    Science.gov (United States)

    Lungevics, J.; Jansons, E.; Gross, K. A.

    2018-02-01

    The ability to slide on ice has previously focused on the measurement of friction coefficient rather than the actual sliding velocity that is affected by it. The performance can only be directly measured by the sliding velocity, and therefore the objective was to design and setup a facility to measure velo-city, and determine how experimental conditions affect it. Optical sensors were placed on an angled ice track to provide sliding velocity measurements along three sections and the velocity for the total sliding distance. Experimental conditions included the surface roughness, ambient temperature and load. The effect of roughness was best reported with a Criterion of Contact that showed a similar sliding velocity for metal blocks abraded with sand paper smoother than 600 grit. Searching for the effect of temperature, the highest sliding velocity coincided with the previously reported lowest coefficient of ice friction. Load showed the greatest velocity increase at temperatures closer to the ice melting point suggesting that in such conditions metal block overcame friction forces more easily than in solid friction. Further research needs to be conducted on a longer ice track, with larger metal surfaces, heavier loads and higher velocities to determine how laboratory experiments can predict real-life situations.

  1. An Ice Track Equipped with Optical Sensors for Determining the Influence of Experimental Conditions on the Sliding Velocity

    Directory of Open Access Journals (Sweden)

    Lungevics J.

    2018-02-01

    Full Text Available The ability to slide on ice has previously focused on the measurement of friction coefficient rather than the actual sliding velocity that is affected by it. The performance can only be directly measured by the sliding velocity, and therefore the objective was to design and setup a facility to measure velo-city, and determine how experimental conditions affect it. Optical sensors were placed on an angled ice track to provide sliding velocity measurements along three sections and the velocity for the total sliding distance. Experimental conditions included the surface roughness, ambient temperature and load. The effect of roughness was best reported with a Criterion of Contact that showed a similar sliding velocity for metal blocks abraded with sand paper smoother than 600 grit. Searching for the effect of temperature, the highest sliding velocity coincided with the previously reported lowest coefficient of ice friction. Load showed the greatest velocity increase at temperatures closer to the ice melting point suggesting that in such conditions metal block overcame friction forces more easily than in solid friction. Further research needs to be conducted on a longer ice track, with larger metal surfaces, heavier loads and higher velocities to determine how laboratory experiments can predict real-life situations.

  2. Optically-tracked handheld fluorescence imaging platform for monitoring skin response in the management of soft tissue sarcoma

    Science.gov (United States)

    Chamma, Emilie; Qiu, Jimmy; Lindvere-Teene, Liis; Blackmore, Kristina M.; Majeed, Safa; Weersink, Robert; Dickie, Colleen I.; Griffin, Anthony M.; Wunder, Jay S.; Ferguson, Peter C.; DaCosta, Ralph S.

    2015-07-01

    Standard clinical management of extremity soft tissue sarcomas includes surgery with radiation therapy. Wound complications (WCs) arising from treatment may occur due to bacterial infection and tissue breakdown. The ability to detect changes in these parameters during treatment may lead to earlier interventions that mitigate WCs. We describe the use of a new system composed of an autofluorescence imaging device and an optical three-dimensional tracking system to detect and coregister the presence of bacteria with radiation doses. The imaging device visualized erythema using white light and detected bacterial autofluorescence using 405-nm excitation light. Its position was tracked relative to the patient using IR reflective spheres and registration to the computed tomography coordinates. Image coregistration software was developed to spatially overlay radiation treatment plans and dose distributions on the white light and autofluorescence images of the surgical site. We describe the technology, its use in the operating room, and standard operating procedures, as well as demonstrate technical feasibility and safety intraoperatively. This new clinical tool may help identify patients at greater risk of developing WCs and investigate correlations between radiation dose, skin response, and changes in bacterial load as biomarkers associated with WCs.

  3. Using optical remote sensing techniques to track the development of ozone-induced stress

    Energy Technology Data Exchange (ETDEWEB)

    Meroni, Michele, E-mail: michele.meroni@unimib.i [Remote Sensing of Environmental Dynamics Laboratory, DISAT, University of Milan-Bicocca, Piazza della Scienza, 1, 20126 Milan (Italy); Panigada, Cinzia; Rossini, Micol [Remote Sensing of Environmental Dynamics Laboratory, DISAT, University of Milan-Bicocca, Piazza della Scienza, 1, 20126 Milan (Italy); Picchi, Valentina [CNR, Plant Virology Institute, Milan Unit, Milan (Italy); Department of Tree Science, Entomology and Plant Pathology ' G. Scaramuzzi' , University of Pisa, Pisa (Italy); Cogliati, Sergio; Colombo, Roberto [Remote Sensing of Environmental Dynamics Laboratory, DISAT, University of Milan-Bicocca, Piazza della Scienza, 1, 20126 Milan (Italy)

    2009-05-15

    In this paper, a literature review about optical remote sensing (RS) of O{sub 3} stress is presented. Studies on O{sub 3}-induced effects on vegetation reflectance have been conducted since late '70s based on the analysis of optical RS data. Literature review reveals that traditional RS techniques were able to detect changes in leaf and canopy reflectance related to O{sub 3}-induced stress when visible symptoms already occurred. Only recently, advanced RS techniques using hyperspectral sensors, demonstrated the feasibility of detecting the stress in its early phase by monitoring excess energy dissipation pathways such as chlorophyll fluorescence and non-photochemical quenching (NPQ). Steady-state fluorescence (Fs), measured by exploiting the Fraunhofer line depth principle and NPQ related xanthophyll-cycle, estimated through the photochemical reflectance index (PRI) responded to O{sub 3} fumigation before visible symptoms occurred. This opens up new possibilities for the early detection of vegetation O{sub 3} stress by means of hyperspectral RS. - Possibilities for the early detection of vegetation O{sub 3} stress by means of optical remote sensing are discussed.

  4. WE-G-BRD-03: Development of a Real-Time Optical Tracking Goggle System (OTGS) for Intracranial Stereotactic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mittauer, K; Yan, G; Lu, B; Barraclough, B; Li, J; Liu, C [University of Florida, Gainesville, FL (United States)

    2014-06-15

    Purpose: Optical tracking systems (OTS) are an acceptable alternative to frame-based stereotactic radiotherapy (SRT). However, current surface-based OTS lack the ability to target exclusively rigid/bony anatomical features. We propose a novel marker-based optical tracking goggle system (OTGS) that provides real-time guidance based on the nose/facial bony anatomy. This ongoing study involves the development and characterization of the OTGS for clinical implementation in intracranial stereotactic radiotherapy. Methods: The OTGS consists of eye goggles, a custom thermoplastic nosepiece, and 6 infrared markers pre-attached to the goggles. A phantom and four healthy volunteers were used to evaluate the calibration/registration accuracy, intrafraction accuracy, interfraction reproducibility, and end-to-end accuracy of the OTGS. The performance of the OTGS was compared with that of the frameless SonArray system and cone-beam computed tomography (CBCT) for volunteer and phantom cases, respectively. The performance of the OTGS with commercial immobilization devices and under treatment conditions (i.e., couch rotation and translation range) was also evaluated. Results: The difference in the calibration/registration accuracy of 24 translations or rotation combinations between CBCT and in-house OTS software was within 0.5 mm/0.4°. The mean intrafraction and interfraction accuracy among the volunteers was 0.004+/−0.4mm with −0.09+/−0.5° (n=6,170) and −0.26+/−0.8mm with 0.15+/0.8° (n=11), respectively. The difference in end-to-end accuracy between the OTGS and CBCT was within 1.3 mm/1.1°. The predetermined marker pattern (1) minimized marker occlusions, (2) allowed for continuous tracking for couch angles +/− 90°, (3) and eliminated individual marker misplacement. The device was feasible with open and half masks for immobilization. Conclusion: Bony anatomical localization eliminated potential errors due to facial hair changes and/or soft tissue deformation. The

  5. Gradient Correlation Method for the Stabilization of Inversion Results of Aerosol Microphysical Properties Retrieved from Profiles of Optical Data

    Directory of Open Access Journals (Sweden)

    Kolgotin Alexei

    2016-01-01

    Full Text Available Correlation relationships between aerosol microphysical parameters and optical data are investigated. The results show that surface-area concentrations and extinction coefficients are linearly correlated with a correlation coefficient above 0.99 for arbitrary particle size distribution. The correlation relationships that we obtained can be used as constraints in our inversion of optical lidar data. Simulation studies demonstrate a significant stabilization of aerosol microphysical data products if we apply the gradient correlation method in our traditional regularization technique.

  6. Implementation and performance of an optical motion tracking system for high resolution brain PET imaging

    Science.gov (United States)

    Lopresti, B. J.; Russo, A.; Jones, W. F.; Fisher, T.; Crouch, D. G.; Altenburger, D. E.; Townsend, D. W.

    1999-12-01

    Head motion during PET scanning is widely regarded as a source of image degradation and resolution loss. Recent improvements in the spatial resolution of state-of-the-art tomographs may be compromised by patient motion during scanning, as these high resolution data will be increasingly susceptible to smaller movements of the head. The authors have developed an opto-electronic motion tracking system based on commercially-available technology that is capable of very accurate real-time measurements of the position and orientation of the patient's head. These positions are transformed to the reference frame of the PET scanner, and could potentially be used to provide motion correction of list-mode emission data on an event-by-event basis.

  7. An adaptive recurrent neural-network controller using a stabilization matrix and predictive inputs to solve a tracking problem under disturbances.

    Science.gov (United States)

    Fairbank, Michael; Li, Shuhui; Fu, Xingang; Alonso, Eduardo; Wunsch, Donald

    2014-01-01

    We present a recurrent neural-network (RNN) controller designed to solve the tracking problem for control systems. We demonstrate that a major difficulty in training any RNN is the problem of exploding gradients, and we propose a solution to this in the case of tracking problems, by introducing a stabilization matrix and by using carefully constrained context units. This solution allows us to achieve consistently lower training errors, and hence allows us to more easily introduce adaptive capabilities. The resulting RNN is one that has been trained off-line to be rapidly adaptive to changing plant conditions and changing tracking targets. The case study we use is a renewable-energy generator application; that of producing an efficient controller for a three-phase grid-connected converter. The controller we produce can cope with the random variation of system parameters and fluctuating grid voltages. It produces tracking control with almost instantaneous response to changing reference states, and virtually zero oscillation. This compares very favorably to the classical proportional integrator (PI) controllers, which we show produce a much slower response and settling time. In addition, the RNN we propose exhibits better learning stability and convergence properties, and can exhibit faster adaptation, than has been achieved with adaptive critic designs. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Analysis system of submicron particle tracks in the fine-grained nuclear emulsion by a combination of hard x-ray and optical microscopy

    International Nuclear Information System (INIS)

    Naka, T.; Asada, T.; Yoshimoto, M.; Katsuragawa, T.; Tawara, Y.; Umemoto, A.; Suzuki, Y.; Terada, Y.; Takeuchi, A.; Uesugi, K.; Kimura, M.

    2015-01-01

    Analyses of nuclear emulsion detectors that can detect and identify charged particles or radiation as tracks have typically utilized optical microscope systems because the targets have lengths from several μm to more than 1000 μm. For recent new nuclear emulsion detectors that can detect tracks of submicron length or less, the current readout systems are insufficient due to their poor resolution. In this study, we developed a new system and method using an optical microscope system for rough candidate selection and the hard X-ray microscope system at SPring-8 for high-precision analysis with a resolution of better than 70 nm resolution. Furthermore, we demonstrated the analysis of submicron-length tracks with a matching efficiency of more than 99% and position accuracy of better than 5 μm. This system is now running semi-automatically

  9. Graded-Index Polymer Optical Fiber with High Thermal Stability of Bandwidth

    Science.gov (United States)

    Ishigure, Takaaki; Sato, Masataka; Nihei, Eisuke; Koike, Yasuhiro

    1998-07-01

    The development of the perfluorinated (PF) polymer based graded-index polymer optical fiber (GI POF) for high-speed data communication is described. It was experimentally confirmed that gigabit data transmission for 500 1000 m at 1.3 µm wavelength was achieved by the low-loss PF polymer based GI POF. The thermal stability of poly (methyl methacrylate) PMMA based GI POF is discussed. We selected several kinds of dopants that can maintain a high glass transition temperature (Tg) of the GI POF core. By using the newly selected dopants, we succeeded in maintaining the parabolic refractive index profile of GI POF with no degradation even at 85 to 90°C for more than 5000 h.

  10. Dynamic Probing of Nanoparticle Stability In Vivo: A Liposomal Model Assessed Using In Situ Microdialysis and Optical Imaging

    OpenAIRE

    Jeng, Chien-Chung; Cheng, Shih-Hsun; Ho, Ja-an Annie; Huang, Sam Hong-Yi; Chang, Jerry C.; Tsai, Pi-Ju; Yang, Chung-Shi; Lo, Leu-Wei

    2011-01-01

    Nanoparticle-mediated drug delivery and controlled release has been a vigorous research area in contemporary nanomedicine. The in vivo stability of nanoparticle delivered on site is a prerequisite for the design of drug-controlled release by any means. In this study, the first methodology comprised of microdialysis and optical imaging to assess the liposome stability in vivo is reported. Macroscopically, we demonstrated the DPPG liposomes with negative surface charge fast accumulated in the ...

  11. Simultaneous dual wavelength eye-tracked ultrahigh resolution retinal and choroidal optical coherence tomography

    DEFF Research Database (Denmark)

    Unterhuber, A.; Povaay, B.; Müller, André

    2013-01-01

    -artifact-free, ultrahigh resolution and high contrast retinal and choroidal imaging. The two wavelengths of the device provide the complementary information needed for diagnosis of subtle retinal changes, while also increasing visibility of deeper-lying layers to image pathologies that include opaque media in the anterior......We demonstrate an optical coherence tomography device that simultaneously combines different novel ultrabroad bandwidth light sources centered in the 800 and 1060 nm regions, operating at 66 kHz depth scan rate, and a confocal laser scanning ophthalmoscope-based eye tracker to permit motion...

  12. Predictability and stability of refraction with increasing optical zone diameter in hyperopic LASIK

    Directory of Open Access Journals (Sweden)

    Mostafa A El-Helw

    2010-05-01

    Full Text Available Mostafa A El-Helw, Ahmed M EmarahCairo University, Cairo, EgyptObjective: We undertook a prospective nonrandomized study to assess refractive outcome and patient satisfaction with hyperopic laser in situ keratomileusis (LASIK using variable optical zone diameters in correction of hyperopia of more than 4.00 diopters.Methods: Fourteen adults (comprising 28 hyperopic eyes underwent hyperopic LASIK correction for hyperopia of more than 4.00 diopters. The sample was divided into two groups. Group 1 included the right eyes of the 14 patients who underwent hyperopic LASIK using a 6.5 mm optical zone diameter. Group 2 comprised the left eyes of the same patients with the only difference being that the optical zone diameter was 6.0 mm.Results: The mean age of the patients was 36.42 ± 5.10 years. Group 1 eyes had a median (range preoperative uncorrected visual acuity (UCVA of 0.79 (0.52 and best-corrected visual acuity (BCVA of 0.15 (0.08. Group 2 had a median preoperative UCVA of 0.79 (0.60 and BCVA of 0.15 (0.08. The median postoperative UCVA in Group 1 was 0.17 (0.21 and BCVA was 0.15 (0.13. In Group 2, the median postoperative UCVA was 0.30 (0.32 and BCVA was 0.15 (0.26. Group 1 had a median preoperative refraction of +5.37 (1.75 diopters and the median postoperative refraction at one week was −0.23 (1.25 diopters, at three months was +0.75 (0.75 diopters, and at six months was +0.75 (1.00 diopters. Group 2 had a median preoperative refraction of +5.00 (1.75 diopters, and the median postoperative refraction at one week was +0.13 (1.5 diopters, at three months was +1.00 (0.75 diopters and at six months +1.25 (1.25 diopters. The difference was statistically significant between groups 1 and 2. The difference within each group was also significant. Group 1 eyes were stabilizing after the three-month period in contrast with Group 2 in which the refractive changes continued throughout the follow-up period.Conclusion: Larger optical zone diameter in

  13. High-Speed Microscale Optical Tracking Using Digital Frequency-Domain Multiplexing.

    Science.gov (United States)

    Maclachlan, Robert A; Riviere, Cameron N

    2009-06-01

    Position-sensitive detectors (PSDs), or lateral-effect photodiodes, are commonly used for high-speed, high-resolution optical position measurement. This paper describes the instrument design for multidimensional position and orientation measurement based on the simultaneous position measurement of multiple modulated sources using frequency-domain-multiplexed (FDM) PSDs. The important advantages of this optical configuration in comparison with laser/mirror combinations are that it has a large angular measurement range and allows the use of a probe that is small in comparison with the measurement volume. We review PSD characteristics and quantitative resolution limits, consider the lock-in amplifier measurement system as a communication link, discuss the application of FDM to PSDs, and make comparisons with time-domain techniques. We consider the phase-sensitive detector as a multirate DSP problem, explore parallels with Fourier spectral estimation and filter banks, discuss how to choose the modulation frequencies and sample rates that maximize channel isolation under design constraints, and describe efficient digital implementation. We also discuss hardware design considerations, sensor calibration, probe construction and calibration, and 3-D measurement by triangulation using two sensors. As an example, we characterize the resolution, speed, and accuracy of an instrument that measures the position and orientation of a 10 mm × 5 mm probe in 5 degrees of freedom (DOF) over a 30-mm cube with 4-μm peak-to-peak resolution at 1-kHz sampling.

  14. Dimensional stability performance of a CFRP sandwich optical bench for microsatellite payload

    Science.gov (United States)

    Desnoyers, N.; Goyette, P.; Leduc, B.; Boucher, M.-A.

    2017-09-01

    Microsatellite market requires high performance while minimizing mass, volume and cost. Telescopes are specifically targeted by these trade-offs. One of these is to use the optomechanical structure of the telescope to mount electronic devices that may dissipate heat. However, such approach may be problematic in terms of distortions due to the presence of high thermal gradients throughout the telescope structure. To prevent thermal distortions, Carbon Fiber Reinforced Polymer (CFRP) technology can be used for the optomechanical telescope material structure. CFRP is typically about 100 times less sensitive to thermal gradients and its coefficient of thermal expansion (CTE) is about 200 to 600 times lower than standard aluminum alloys according to inhouse measurements. Unfortunately, designing with CFRP material is not as straightforward as with metallic materials. There are many parameters to consider in order to reach the desired dimensional stability under thermal, moisture and vibration exposures. Designing optomechanical structures using CFRP involves many challenges such as interfacing with optics and sometimes dealing with high CTE mounting interface structures like aluminum spacecraft buses. INO has designed a CFRP sandwich telescope structure to demonstrate the achievable performances of such technology. Critical parameters have been optimized to maximize the dimensional stability while meeting the stringent environmental requirements that microsatellite payloads have to comply with. The telescope structure has been tested in vacuum from -40°C to +50°C and has shown a good fit with finite element analysis predictions.

  15. Modulation stability and dispersive optical soliton solutions of higher order nonlinear Schrödinger equation and its applications in mono-mode optical fibers

    Science.gov (United States)

    Arshad, Muhammad; Seadawy, Aly R.; Lu, Dianchen

    2018-01-01

    In mono-mode optical fibers, the higher order non-linear Schrödinger equation (NLSE) describes the propagation of enormously short light pulses. We constructed optical solitons and, solitary wave solutions of higher order NLSE mono-mode optical fibers via employing modified extended mapping method which has important applications in Mathematics and physics. Furthermore, the formation conditions are also given on parameters in which optical bright and dark solitons can exist for this media. The moment of the obtained solutions are also given graphically, that helps to realize the physical phenomena's of this model. The modulation instability analysis is utilized to discuss the model stability, which verifies that all obtained solutions are exact and stable. Many other such types of models arising in applied sciences can also be solved by this reliable, powerful and effective method. The method can also be functional to other sorts of higher order nonlinear problems in contemporary areas of research.

  16. Monitoring and tracking the trans-Pacific transport of aerosols using multi-satellite aerosol optical depth retrievals

    Science.gov (United States)

    Naeger, A. R.; Gupta, P.; Zavodsky, B.; McGrath, K. M.

    2015-10-01

    The primary goal of this study was to generate a near-real time (NRT) aerosol optical depth (AOD) product capable of providing a comprehensive understanding of the aerosol spatial distribution over the Pacific Ocean in order to better monitor and track the trans-Pacific transport of aerosols. Therefore, we developed a NRT product that takes advantage of observations from both low-earth orbiting and geostationary satellites. In particular, we utilize AOD products from the Moderate Resolution Imaging Spectroradiometer (MODIS) and Suomi National Polar-orbiting Partnership (NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) satellites. Then, we combine these AOD products with our own retrieval algorithms developed for the NOAA Geostationary Operational Environmental Satellite (GOES-15) and Japan Meteorological Agency (JMA) Multi-functional Transport Satellite (MTSAT-2) to generate a NRT daily AOD composite product. We present examples of the daily AOD composite product for a case study of trans-Pacific transport of Asian pollution and dust aerosols in mid-March 2014. Overall, the new product successfully tracks this aerosol plume during its trans-Pacific transport to the west coast of North America. However, we identify several areas across the domain of interest from Asia to North America where the new product can encounter significant uncertainties due to the inclusion of the geostationary AOD retrievals. The uncertainties associated with geostationary AOD retrievals are expected to be minimized after the successful launch of the next-generation advanced NOAA GOES-R and recently launched JMA Himawari satellites. Observations from these advanced satellites will ultimately provide an enhanced understanding of the spatial and temporal distribution of aerosols over the Pacific.

  17. Monitoring and tracking the trans-Pacific transport of aerosols using multi-satellite aerosol optical depth composites

    Science.gov (United States)

    Naeger, Aaron R.; Gupta, Pawan; Zavodsky, Bradley T.; McGrath, Kevin M.

    2016-06-01

    The primary goal of this study was to generate a near-real time (NRT) aerosol optical depth (AOD) product capable of providing a comprehensive understanding of the aerosol spatial distribution over the Pacific Ocean, in order to better monitor and track the trans-Pacific transport of aerosols. Therefore, we developed a NRT product that takes advantage of observations from both low-earth orbiting and geostationary satellites. In particular, we utilize AOD products from the Moderate Resolution Imaging Spectroradiometer (MODIS) and Suomi National Polar-orbiting Partnership (NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) satellites. Then, we combine these AOD products with our own retrieval algorithms developed for the NOAA Geostationary Operational Environmental Satellite (GOES-15) and Japan Meteorological Agency (JMA) Multi-functional Transport Satellite (MTSAT-2) to generate a NRT daily AOD composite product. We present examples of the daily AOD composite product for a case study of trans-Pacific transport of Asian pollution and dust aerosols in mid-March 2014. Overall, the new product successfully tracks this aerosol plume during its trans-Pacific transport to the west coast of North America as the frequent geostationary observations lead to a greater coverage of cloud-free AOD retrievals equatorward of about 35° N, while the polar-orbiting satellites provide a greater coverage of AOD poleward of 35° N. However, we note several areas across the domain of interest from Asia to North America where the GOES-15 and MTSAT-2 retrieval algorithms can introduce significant uncertainties into the new product.

  18. Intrasurgical Human Retinal Imaging With Manual Instrument Tracking Using a Microscope-Integrated Spectral-Domain Optical Coherence Tomography Device.

    Science.gov (United States)

    Hahn, Paul; Carrasco-Zevallos, Oscar; Cunefare, David; Migacz, Justin; Farsiu, Sina; Izatt, Joseph A; Toth, Cynthia A

    2015-07-01

    To characterize the first in-human intraoperative imaging using a custom prototype spectral-domain microscope-integrated optical coherence tomography (MIOCT) device during vitreoretinal surgery with instruments in the eye. Under institutional review board approval for a prospective intraoperative study, MIOCT images were obtained at surgical pauses with instruments held static in the vitreous cavity and then concurrently with surgical maneuvers. Postoperatively, MIOCT images obtained at surgical pauses were compared with images obtained with a high-resolution handheld spectral-domain OCT (HHOCT) system with objective endpoints, including acquisition of images acceptable for analysis and identification of predefined macular morphologic or pathologic features. Human MIOCT images were successfully obtained before incision and during pauses in surgical maneuvers. MIOCT imaging confirmed preoperative diagnoses, such as epiretinal membrane, full-thickness macular hole, and vitreomacular traction and demonstrated successful achievement of surgical goals. MIOCT and HHOCT images obtained at surgical pauses in two cohorts of five patients were comparable with greater than or equal to 80% correlation in 80% of patients. Real-time video-imaging concurrent with surgical manipulations enabled, for the first time using this device, visualization of dynamic instrument-retina interaction with targeted OCT tracking. MIOCT is successful for imaging at surgical pauses and for real-time image guidance with implementation of targeted OCT tracking. Even faster acquisition speeds are currently being developed with incorporation of a swept-source MIOCT engine. Further refinements and investigations will be directed toward continued integration for real-time volumetric imaging of surgical maneuvers. Ongoing development of seamless MIOCT systems will likely transform surgical visualization, approaches, and decision-making.

  19. Investigations of repetition rate stability of a mode-locked quantum dot semiconductor laser in an auxiliary optical fiber cavity

    DEFF Research Database (Denmark)

    Breuer, Stefan; Elsässer, Wolfgang; McInerney, J.G.

    2010-01-01

    We have investigated experimentally the pulse train (mode beating) stability of a monolithic mode-locked multi-section quantum-dot laser with an added passive auxiliary optical fiber cavity. Addition of the weakly coupled (¿ -24dB) cavity reduces the current-induced shift d¿/dI of the principal...

  20. Enhanced Optical Head Tracking for Cranial Radiation Therapy: Supporting Surface Registration by Cutaneous Structures

    Energy Technology Data Exchange (ETDEWEB)

    Wissel, Tobias, E-mail: wissel@rob.uni-luebeck.de [Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck (Germany); Graduate School for Computing in Medicine and Life Science, University of Lübeck, Lübeck (Germany); Stüber, Patrick; Wagner, Benjamin [Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck (Germany); Graduate School for Computing in Medicine and Life Science, University of Lübeck, Lübeck (Germany); Bruder, Ralf [Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck (Germany); Erdmann, Christian [Institute for Neuroradiology, Universitätsklinikum Schleswig-Hostein, Campus Lübeck, Lübeck (Germany); Deutz, Christin-Sophie [Clinic for Oral and Maxillo-Facial Surgery, Universitätsklinikum Schleswig-Hostein, Campus Lübeck, Lübeck (Germany); Sack, Benjamin [Department of Neurology, Universitätsklinikum Schleswig-Hostein, Campus Lübeck, Lübeck (Germany); Manit, Jirapong [Institute for Robotics and Cognitive Systems, University of Lübeck, Lübeck (Germany); Graduate School for Computing in Medicine and Life Science, University of Lübeck, Lübeck (Germany); and others

    2016-06-01

    Purpose: To support surface registration in cranial radiation therapy by structural information. The risk for spatial ambiguities is minimized by using tissue thickness variations predicted from backscattered near-infrared (NIR) light from the forehead. Methods and Materials: In a pilot study we recorded NIR surface scans by laser triangulation from 30 volunteers of different skin type. A ground truth for the soft-tissue thickness was segmented from MR scans. After initially matching the NIR scans to the MR reference, Gaussian processes were trained to predict tissue thicknesses from NIR backscatter. Moreover, motion starting from this initial registration was simulated by 5000 random transformations of the NIR scan away from the MR reference. Re-registration to the MR scan was compared with and without tissue thickness support. Results: By adding prior knowledge to the backscatter features, such as incident angle and neighborhood information in the scanning grid, we showed that tissue thickness can be predicted with mean errors of <0.2 mm, irrespective of the skin type. With this additional information, the average registration error improved from 3.4 mm to 0.48 mm by a factor of 7. Misalignments of more than 1 mm were almost thoroughly (98.9%) pushed below 1 mm. Conclusions: For almost all cases tissue-enhanced matching achieved better results than purely spatial registration. Ambiguities can be minimized if the cutaneous structures do not agree. This valuable support for surface registration increases tracking robustness and avoids misalignment of tumor targets far from the registration site.

  1. Enhanced Optical Head Tracking for Cranial Radiation Therapy: Supporting Surface Registration by Cutaneous Structures

    International Nuclear Information System (INIS)

    Wissel, Tobias; Stüber, Patrick; Wagner, Benjamin; Bruder, Ralf; Erdmann, Christian; Deutz, Christin-Sophie; Sack, Benjamin; Manit, Jirapong

    2016-01-01

    Purpose: To support surface registration in cranial radiation therapy by structural information. The risk for spatial ambiguities is minimized by using tissue thickness variations predicted from backscattered near-infrared (NIR) light from the forehead. Methods and Materials: In a pilot study we recorded NIR surface scans by laser triangulation from 30 volunteers of different skin type. A ground truth for the soft-tissue thickness was segmented from MR scans. After initially matching the NIR scans to the MR reference, Gaussian processes were trained to predict tissue thicknesses from NIR backscatter. Moreover, motion starting from this initial registration was simulated by 5000 random transformations of the NIR scan away from the MR reference. Re-registration to the MR scan was compared with and without tissue thickness support. Results: By adding prior knowledge to the backscatter features, such as incident angle and neighborhood information in the scanning grid, we showed that tissue thickness can be predicted with mean errors of <0.2 mm, irrespective of the skin type. With this additional information, the average registration error improved from 3.4 mm to 0.48 mm by a factor of 7. Misalignments of more than 1 mm were almost thoroughly (98.9%) pushed below 1 mm. Conclusions: For almost all cases tissue-enhanced matching achieved better results than purely spatial registration. Ambiguities can be minimized if the cutaneous structures do not agree. This valuable support for surface registration increases tracking robustness and avoids misalignment of tumor targets far from the registration site.

  2. Optical Orbit Determination of a Geosynchronous Earth Orbit Satellite Effected by Baseline Distances between Various Ground-based Tracking Stations I: COMS simulation case

    Directory of Open Access Journals (Sweden)

    Ju Young Son

    2015-09-01

    Full Text Available To protect and manage the Korean space assets including satellites, it is important to have precise positions and orbit information of each space objects. While Korea currently lacks optical observatories dedicated to satellite tracking, the Korea Astronomy and Space Science Institute (KASI is planning to establish an optical observatory for the active generation of space information. However, due to geopolitical reasons, it is difficult to acquire an adequately sufficient number of optical satellite observatories in Korea. Against this backdrop, this study examined the possible locations for such observatories, and performed simulations to determine the differences in precision of optical orbit estimation results in relation to the relative baseline distance between observatories. To simulate more realistic conditions of optical observation, white noise was introduced to generate observation data, which was then used to investigate the effects of baseline distance between optical observatories and the simulated white noise. We generated the optical observations with white noise to simulate the actual observation, estimated the orbits with several combinations of observation data from the observatories of various baseline differences, and compared the estimated orbits to check the improvement of precision. As a result, the effect of the baseline distance in combined optical GEO satellite observation is obvious but small compared to the observation resolution limit of optical GEO observation.

  3. Tracking evolution of myoglobin stability in cetaceans using experimentally calibrated computational methods that account for generic protein relaxation

    DEFF Research Database (Denmark)

    Holm, Jeppe; Dasmeh, Pouria; Kepp, Kasper Planeta

    2016-01-01

    that predicts multi-site ΔΔG as accurately as standard methods do for single-site mutations and reproduces trends in contemporary myoglobin stabilities. We then apply this new method to the study of the evolution of Mb stability in cetaceans: With both methods the main change in stability (about 1 kcal...

  4. Acquisition, tracking, and pointing; Proceedings of the Meeting, Orlando, FL, Apr. 3, 4, 1986

    Science.gov (United States)

    Auelmann, Richard R. (Editor); Richard, Herbert L. (Editor)

    1987-01-01

    The present conference discusses the effect of target signatures on active tracking, the high resolution obtainable with a two-degrees-of-freedom angle sensor having a high update rate, solar object tracking for the Hubble Space Telescope, scaled experiments for the assessment of precise active tracking, and large aperture high-accuracy satellite laser tracking. Also discussed are laboratory test results for the Spaceborne Geodynamic Ranging System's high speed optical tracking system, jitter stabilization for precise optical pointing, scan stabilization and jitter control for an airborne telescope, a simulation of the Solar Optical Telescope's pointing performance, a microprocessor-based dual-speed angle converter, and image localization for alignment by means of adaptive preprocessing.

  5. Optical derotator alignment using image-processing algorithm for tracking laser vibrometer measurements of rotating objects

    Science.gov (United States)

    Khalil, Hossam; Kim, Dongkyu; Jo, Youngjoon; Park, Kyihwan

    2017-06-01

    An optical component called a Dove prism is used to rotate the laser beam of a laser-scanning vibrometer (LSV). This is called a derotator and is used for measuring the vibration of rotating objects. The main advantage of a derotator is that it works independently from an LSV. However, this device requires very specific alignment, in which the axis of the Dove prism must coincide with the rotational axis of the object. If the derotator is misaligned with the rotating object, the results of the vibration measurement are imprecise, owing to the alteration of the laser beam on the surface of the rotating object. In this study, a method is proposed for aligning a derotator with a rotating object through an image-processing algorithm that obtains the trajectory of a landmark attached to the object. After the trajectory of the landmark is mathematically modeled, the amount of derotator misalignment with respect to the object is calculated. The accuracy of the proposed method for aligning the derotator with the rotating object is experimentally tested.

  6. Investigation of optical properties of Cu/Ni multilayer nanowires embedded in etched ion-track template

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Lu [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Yao, Huijun, E-mail: Yaohuijun@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Duan, Jinglai; Chen, Yonghui [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Lyu, Shuangbao [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100049 (China); Maaz, Khan [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Nanomaterials Research Group, Physics Division, PINSTECH, Nilore 45650, Islamabad (Pakistan); Mo, Dan [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Liu, Jie, E-mail: J.Liu@impcas.ac.cn [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Sun, Youmei; Hou, Mingdong [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000 (China)

    2016-12-01

    Graphical abstract: The schematic diagram of measurement of extinction spectra of Cu/Ni multilayer nanowire arrays embedded in the template after removing the gold/copper substrate. - Highlights: • The optical properties of Cu/Ni multilayer nanowire arrays were first investigated by UV/Vis/NIR spectrometer and it was confirmed that the extinction peaks strongly related to the periodicity of the multilayer nanowire. • The Ni segment was thought as a kind of impurity which can change the surface electron distribution and thereby the extinction peaks of nanowire. • Current work supplied the clear layer thickness information of Cu and Ni in Cu/Ni multilayer nanowire with TEM and EDS line-scan profile analysis. - Abstract: For understanding the interaction between light and noble/magnetism multilayer nanowires, Cu/Ni multilayer nanowires are fabricated by a multi-potential step deposition technique in etched ion-track polycarbonate template. The component and the corresponding layer thickness of multilayer nanowire are confirmed by TEM and EDS line-scan analysis. By tailoring the nanowire diameter, the Cu layer thickness and the periodicity of the nanowire, the extinction spectral of nanowire arrays exhibit an extra sensitivity to the change of structural parameters. The resonance wavelength caused by surface plasmon resonance increases obviously with increasing the nanowire diameter, the Cu layer thickness and the periodicity. The observations in our work can be explained by the “impurity effect” and coupled effect and can also be optimized for developing optical devices based on multilayer nanowires.

  7. NEOSTEL: the telescope detail design program for the ESA optical ground network dedicated to NEO discovery and tracking

    Science.gov (United States)

    Cibin, L.; Chiarini, M.; Bernardi, F.; Ragazzoni, R.; Salinari, P.

    The Fly-Eye architecture applied for a Space Debris and NEO Surveillance and Tracking optical telescope has been originally proposed by CGS and further refined in the framework of the Space Situational Awareness (SSA) Preparatory Program studies. The high level architecture of a Telescope based on the Fly-Eye concept has been defined in the TELAD Study. Following TELAD conceptual design, the activities of NEOSTEL aim now at generating the Detailed Design of a NEO Survey Telescope based on the Fly-Eye concept. All components of the telescope are designed at detailed level to satisfy the specific requirements for the Survey and Follow Up of the Near Earth Objects. The NEO Survey Telescope detailed design generated under this Program will be directly utilized for the manufacturing of the first prototype, planned to be launched by the SSA Program in the second half of 2015. In addition, the result of the Detailed Design will produce the documentation necessary to prepare the future site that will host the NEO Survey Telescope prototype as well as the high level architecture of the data processing SW that will be required at the telescope site. The product of the prototypation activity will then constitute a full Italian key Optical Core Technology, dedicated to the NEO thematic but also extendable to the SST Segment, therefore offering possibility of application both at Civil and at Institutional level. Furthermore the Fly-Eye Telescope Technology can actively collaborate with a dedicated Space Segment, opening the way to a complete and autonomous EU System.

  8. Can whitening toothpastes maintain the optical stability of enamel over time?

    Directory of Open Access Journals (Sweden)

    Eduardo Moreira da Silva

    2018-02-01

    Full Text Available Abstract Besides the effects on the health of individuals, cigarette smoking can also interfere with the appearance of their teeth. Objective: To evaluate the effect of cigarette smoking-toothbrushing-cycling (CSTC with whitening toothpastes on the roughness and optical behavior of bovine enamel for eight weeks. Material and Methods: Thirty bovine dentin/enamel discs, 8.0 mm in diameter and 2.0 mm thick, were randomly divided into three groups according to the toothpastes: whitening (Colgate Luminous White - CW and Oral B 3D White - OW, and a non-whitening (Colgate - C. The roughness, color (CIE L*a*b* system, translucency and gloss were measured before and after the specimens were submitted to CSTC. The topography of the specimens was analyzed by scanning electron microscopy. During the first week, the specimens were daily subjected to the consumption of 20 cigarettes and brushed (40 strokes/100 g with the toothpastes' slurries. Thereafter, the CSTC was weekly applied in an accumulated model (140 cigarettes/280 strokes for seven weeks. The data were submitted to two-way ANOVA, Tukey's HSD test, and paired-t test (α=0.05. Results: The three toothpastes produced significant changes in roughness, color, translucency and gloss (p0.05, while OW produced the lowest color change and the translucency of C was lower than that of CW (p<0.05. The three toothpastes produced a significant decrease in L* values and a significant increase in a* values after eight weeks (p<0.05. No significant difference in the b* coordinate was found for OW (p=0.13 There were topographic changes in the enamel surfaces. Conclusions: The whitening toothpastes increased the roughness, changed the topography and were not able to maintain the optical stability of enamel exposed over eight weeks.

  9. Feasibility of integrating a multi-camera optical tracking system in intra-operative electron radiation therapy scenarios

    International Nuclear Information System (INIS)

    García-Vázquez, V; Marinetto, E; Santos-Miranda, J A; Calvo, F A; Desco, M; Pascau, J

    2013-01-01

    Intra-operative electron radiation therapy (IOERT) combines surgery and ionizing radiation applied directly to an exposed unresected tumour mass or to a post-resection tumour bed. The radiation is collimated and conducted by a specific applicator docked to the linear accelerator. The dose distribution in tissues to be irradiated and in organs at risk can be planned through a pre-operative computed tomography (CT) study. However, surgical retraction of structures and resection of a tumour affecting normal tissues significantly modify the patient's geometry. Therefore, the treatment parameters (applicator dimension, pose (position and orientation), bevel angle, and beam energy) may require the original IOERT treatment plan to be modified depending on the actual surgical scenario. We propose the use of a multi-camera optical tracking system to reliably record the actual pose of the IOERT applicator in relation to the patient's anatomy in an environment prone to occlusion problems. This information can be integrated in the radio-surgical treatment planning system in order to generate a real-time accurate description of the IOERT scenario. We assessed the accuracy of the applicator pose by performing a phantom-based study that resembled three real clinical IOERT scenarios. The error obtained (2 mm) was below the acceptance threshold for external radiotherapy practice, thus encouraging future implementation of this approach in real clinical IOERT scenarios. (paper)

  10. Description of an evaluation system for knee kinematics in ligament lesions, by means of optical tracking and 3D tomography,

    Directory of Open Access Journals (Sweden)

    Tiago Lazzaretti Fernandes

    2014-10-01

    Full Text Available Objective:To describe and demonstrate the viability of a method for evaluating knee kine matics, by means of a continuous passive motion (CPM machine, before and after anterio cruciate ligament (ACL injury.Methods:This study was conducted on a knee from a cadaver, in a mechanical pivot-shif simulator, with evaluations using optical tracking, and also using computed tomography.Results:This study demonstrated the viability of a protocol for measuring the rotation an translation of the knee, using reproducible and objective tools (error<0.2mm. The mech anized provocation system of the pivot-shift test was independent of the examiner an always allowed the same angular velocity and traction of 20 N throughout the movement.Conclusion:The clinical relevance of this method lies in making inferences about the in viv behavior of a knee with an ACL injury and providing greater methodological quality in futur studies for measuring surgical techniques with grafts in relatively close positions.

  11. Force measuring optical tweezers system for long time measurements of P pili stability

    Science.gov (United States)

    Andersson, Magnus; Fällman, Erik; Uhlin, Bernt Eric; Axner, Ove

    2006-02-01

    A force-measuring optical tweezers instrumentation and long time measurements of the elongation and retraction of bacterial fimbriae from Uropathogenic E. coli (UPEC) under strain are presented. The instrumentation is presented in some detail. Special emphasis is given to measures taken to reduce the influence of noise and drifts in the system and from the surrounding, which makes long term force measurements possible. Individual P pili from UPEC bacteria were used as a biological model system for repetitive unfolding and refolding cycles of bacterial fimbriae under equilibrium conditions. P pili have evolved into a three-dimensional helix-like structure, the PapA rod, that can be successively and significantly elongated and/or unfolded when exposed to external forces. The instrumentation is used for characterization of the force-vs.-elongation response of the PapA rod of individual P pili, with emphasis on the long time stability of the forced unfolding and refolding of the helical structure of the PapA rod. The results show that the PapA rod is capable of withstanding extensive strain, leading to a complete unfolding of the helical structure, repetitive times during the life cycle of a bacterium without any noticeable alteration of the mechanical properties of the P pili. This function is believed to be importance for UPEC bacteria in vivo since it provides a close contact to a host cell (which is an initial step of invasion) despite urine cleaning attempts.

  12. Field calculations, single-particle tracking, and beam dynamics with space charge in the electron lens for the Fermilab Integrable Optics Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Noll, Daniel [Goethe Univ., Frankfurt (Germany); Stancari, Giulio [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2015-11-17

    An electron lens is planned for the Fermilab Integrable Optics Test Accelerator as a nonlinear element for integrable dynamics, as an electron cooler, and as an electron trap to study space-charge compensation in rings. We present the main design principles and constraints for nonlinear integrable optics. A magnetic configuration of the solenoids and of the toroidal section is laid out. Singleparticle tracking is used to optimize the electron path. Electron beam dynamics at high intensity is calculated with a particle-in-cell code to estimate current limits, profile distortions, and the effects on the circulating beam. In the conclusions, we summarize the main findings and list directions for further work.

  13. Optical Materials with a Genome: Nanophotonics with DNA-Stabilized Silver Clusters

    Science.gov (United States)

    Copp, Stacy M.

    Fluorescent silver clusters with unique rod-like geometries are stabilized by DNA. The sizes and colors of these clusters, or AgN-DNA, are selected by DNA base sequence, which can tune peak emission from blue-green into the near-infrared. Combined with DNA nanostructures, AgN-DNA promise exciting applications in nanophotonics and sensing. Until recently, however, a lack of understanding of the mechanisms controlling AgN-DNA fluorescence has challenged such applications. This dissertation discusses progress toward understanding the role of DNA as a "genome" for silver clusters and toward using DNA to achieve atomic-scale precision of silver cluster size and nanometer-scale precision of silver cluster position on a DNA breadboard. We also investigate sensitivity of AgN-DNA to local solvent environment, with an eye toward applications in chemical and biochemical sensing. Using robotic techniques to generate large data sets, we show that fluorescent silver clusters are templated by certain DNA base motifs that select "magic-sized" cluster cores of enhanced stabilities. The linear arrangement of bases on the phosphate backbone imposes a unique rod-like geometry on the clusters. Harnessing machine learning and bioinformatics techniques, we also demonstrate that sequences of DNA templates can be selected to stabilize silver clusters with desired optical properties, including high fluorescence intensity and specific fluorescence wavelengths, with much higher rates of success as compared to current strategies. The discovered base motifs can be also used to design modular DNA host strands that enable individual silver clusters with atomically precise sizes to bind at specific programmed locations on a DNA nanostructure. We show that DNA-mediated nanoscale arrangement enables near-field coupling of distinct clusters, demonstrated by dual-color cluster assemblies exhibiting resonant energy transfer. These results demonstrate a new degree of control over the optical properties

  14. CSSTag: Optical Nanoscale Radar and Particle Tracking for In-Body and Microfluidic Systems With Vibrating Graphene and Resonance Energy Transfer.

    Science.gov (United States)

    Gulbahar, Burhan; Memisoglu, Gorkem

    2017-12-01

    Biological particle tracking systems monitor cellular processes or particle behaviors with the great accuracy. The emissions of fluorescent molecules or direct images of particles are captured with cameras or photodetectors. The current imaging systems have challenges in detection, collection, and analysis of imaging data, penetration depth, and complicated set-ups. In this paper, a signaling-based nanoscale acousto-optic radar and microfluidic multiple particle tracking (MPT) system is proposed based on the theoretical design providing nanoscale optical modulator with vibrating Förster resonance energy transfer and vibrating cadmium selenide/zinc sulfide quantum dots (QDs) on graphene resonators. The modulator combines significant advantages of graphene membranes having wideband resonance frequencies with QDs having broad absorption spectrum and tunable properties. The solution denoted by chirp spread spectrum(CSS) Tag utilizes classical radar target tracking approaches in nanoscale environments based on the capability to generate CSS sequences identifying different bio-particles. Monte Carlo simulations show significant performance for MPT with a modulator of dimension and several picograms of weight, the signal-to-noise ratio in the range from -7 to 10 dB, simple light emitting diode sources with power less than 4 W/cm 2 and high speed tracking for microfluidic environments.

  15. Utilization of optical tracking to validate a software-driven isocentric approach to robotic couch movements for proton radiotherapy

    International Nuclear Information System (INIS)

    Hsi, Wen C.; Zeidan, Omar A.; Law, Aaron; Schreuder, Andreas N.

    2014-01-01

    Purpose: An optical tracking and positioning system (OTPS) was developed to validate the software-driven isocentric (SDI) approach to control the six-degrees-of-freedom movement of a robotic couch. Methods: The SDI approach to movements rotating around a predefined isocenter, referred to as a GeoIso, instead of a mechanical pivot point was developed by the robot automation industry. With robotic couch-sag corrections for weight load in a traditional SDI approach, movements could be accurately executed for a GeoIso located within a 500 mm cubic volume on the couch for treatments. The accuracy of SDI movement was investigated using the OTPS. The GeoIso was assumed to align with the proton beam isocenter (RadIso) for gantry at the reference angle. However, the misalignment between GeoIso and RadIso was quantitatively investigated by measuring the displacements at various couch angles for a target placed at the RadIso at an initial couch angle. When circular target displacements occur on a plane, a relative isocenter shift (RIS) correction could be applied in the SDI movement to minimize target displacements. Target displacements at a fixed gantry angle without and with RIS correction were measured for 12 robotic couches. Target displacements for various gantry angles were performed on three couches in gantry rooms to study the gantry-induced RadIso shift. The RIS correction can also be applied for the RadIso shift. A new SDI approach incorporating the RIS correction with the couch sag is described in this study. In parallel, the accuracy of SDI translation movements for various weight loads of patients on the couch was investigated during positioning of patients for proton prostate treatments. Results: For a fixed gantry angle, measured target displacements without RIS correction for couch rotations in the horizontal plane varied from 4 to 20 mm. However, measured displacements perpendicular to couch rotation plane were about 2 mm for all couches. Extracted

  16. Utilization of optical tracking to validate a software-driven isocentric approach to robotic couch movements for proton radiotherapy.

    Science.gov (United States)

    Hsi, Wen C; Law, Aaron; Schreuder, Andreas N; Zeidan, Omar A

    2014-08-01

    An optical tracking and positioning system (OTPS) was developed to validate the software-driven isocentric (SDI) approach to control the six-degrees-of-freedom movement of a robotic couch. The SDI approach to movements rotating around a predefined isocenter, referred to as a GeoIso, instead of a mechanical pivot point was developed by the robot automation industry. With robotic couch-sag corrections for weight load in a traditional SDI approach, movements could be accurately executed for a GeoIso located within a 500 mm cubic volume on the couch for treatments. The accuracy of SDI movement was investigated using the OTPS. The GeoIso was assumed to align with the proton beam isocenter (RadIso) for gantry at the reference angle. However, the misalignment between GeoIso and RadIso was quantitatively investigated by measuring the displacements at various couch angles for a target placed at the RadIso at an initial couch angle. When circular target displacements occur on a plane, a relative isocenter shift (RIS) correction could be applied in the SDI movement to minimize target displacements. Target displacements at a fixed gantry angle without and with RIS correction were measured for 12 robotic couches. Target displacements for various gantry angles were performed on three couches in gantry rooms to study the gantry-induced RadIso shift. The RIS correction can also be applied for the RadIso shift. A new SDI approach incorporating the RIS correction with the couch sag is described in this study. In parallel, the accuracy of SDI translation movements for various weight loads of patients on the couch was investigated during positioning of patients for proton prostate treatments. For a fixed gantry angle, measured target displacements without RIS correction for couch rotations in the horizontal plane varied from 4 to 20 mm. However, measured displacements perpendicular to couch rotation plane were about 2 mm for all couches. Extracted misalignments of GeoIso and RadIso in

  17. Utilization of optical tracking to validate a software-driven isocentric approach to robotic couch movements for proton radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hsi, Wen C., E-mail: Wen.Hsi@Mclaren.org, E-mail: Wenchien.hsi@sphic.org.cn; Zeidan, Omar A., E-mail: omar.zeidan@orlandohealth.com [ProCure Proton Therapy Center, Oklahoma City, Oklahoma 73142 (United States); Law, Aaron; Schreuder, Andreas N., E-mail: niek.schreuder@provisionhp.com [ProCure Training and Development Center, Bloomington, Indiana 47404 (United States)

    2014-08-15

    Purpose: An optical tracking and positioning system (OTPS) was developed to validate the software-driven isocentric (SDI) approach to control the six-degrees-of-freedom movement of a robotic couch. Methods: The SDI approach to movements rotating around a predefined isocenter, referred to as a GeoIso, instead of a mechanical pivot point was developed by the robot automation industry. With robotic couch-sag corrections for weight load in a traditional SDI approach, movements could be accurately executed for a GeoIso located within a 500 mm cubic volume on the couch for treatments. The accuracy of SDI movement was investigated using the OTPS. The GeoIso was assumed to align with the proton beam isocenter (RadIso) for gantry at the reference angle. However, the misalignment between GeoIso and RadIso was quantitatively investigated by measuring the displacements at various couch angles for a target placed at the RadIso at an initial couch angle. When circular target displacements occur on a plane, a relative isocenter shift (RIS) correction could be applied in the SDI movement to minimize target displacements. Target displacements at a fixed gantry angle without and with RIS correction were measured for 12 robotic couches. Target displacements for various gantry angles were performed on three couches in gantry rooms to study the gantry-induced RadIso shift. The RIS correction can also be applied for the RadIso shift. A new SDI approach incorporating the RIS correction with the couch sag is described in this study. In parallel, the accuracy of SDI translation movements for various weight loads of patients on the couch was investigated during positioning of patients for proton prostate treatments. Results: For a fixed gantry angle, measured target displacements without RIS correction for couch rotations in the horizontal plane varied from 4 to 20 mm. However, measured displacements perpendicular to couch rotation plane were about 2 mm for all couches. Extracted

  18. Micro-electro-mechanical-system (MEMS)-based fiber optic grating sensor for improving weapon stabilization and fire control

    Science.gov (United States)

    Zhang, Sean Z.; Xu, Guoda; Qui, Wei; Lin, Freddie S.; Testa, Robert C.; Mattice, Michael S.

    2000-06-01

    A MEMS-based fiber optic grating sensor (FOGS) for improving weapon stabilization and fire control has been investigated and developed. The technique overwrites two fiber Bragg gratings (FBGs) onto a polarization-preserving optical fiber core. A MEMS diaphragm is fabricated and integrated with the overlaid FBGs to enhance the performance and reliability of the sensor. A simulation model for the MEMS-FOGS was derived, and simulation results concerning load, angle, strain, and temperature were obtained. The fabricated MEMS diaphragm and the overlaid FBGs are packaged together and mounted on a specially designed cantilever beam system. User-friendly software for sensing system design and data analysis has been developed and can be used to control other sensing systems. The combined multifunctional sensitive. The fully developed sensing system is expected to find applications in fire control, weapon stabilization, and other areas where accurately sensing strain and temperature is critical.

  19. The Ceres gravity field, spin pole, rotation period and orbit from the Dawn radiometric tracking and optical data

    Science.gov (United States)

    Konopliv, A. S.; Park, R. S.; Vaughan, A. T.; Bills, B. G.; Asmar, S. W.; Ermakov, A. I.; Rambaux, N.; Raymond, C. A.; Castillo-Rogez, J. C.; Russell, C. T.; Smith, D. E.; Zuber, M. T.

    2018-01-01

    Ceres' gravity field and rotational parameters have been precisely measured using 1.5 years of radiometric Doppler and range data and optical landmark tracking from the Dawn spacecraft in orbit about the dwarf planet. As was the case with Dawn at Vesta, the gravity field, orientation parameters, landmark locations, and Ceres' orbit are jointly estimated in a global solution. Even though Dawn's radio science investigation at Ceres was complicated by additional thrusting for attitude control, the resulting spherical harmonic gravity field has a half-wavelength resolution of up to 82 km (degree 18) near the equator, which is similar harmonic resolution to that of Vesta. The gravity field is consistent with Airy isostatic compensation, and this model assumption limits Ceres' crustal density to be between 1200 and 1600 kg/m3 for two-layer and three-layer models with mean crustal thickness between 27 and 43 km. The compensation depth is determined using admittance between gravity and gravity from topography and is superior to admittance between gravity and topography. The gravitational mass of Ceres is determined to better than 0.002% (GMCeres = 62.62736 ± 0.00040 km3/s2), the spin pole location is improved by 10× over previous results with right ascension (α = 291.427°) and declination (δ = 66.760°) uncertainty less than 0.001°, and the rotation rate is improved by ∼100× over previous determinations from Hubble Space Telescope (HST) images. Ceres' heliocentric orbit has also been improved, with about 17 months of precision range measurements reducing ephemeris uncertainties to about 10 m during the Dawn timeframe.

  20. TriPer, an optical probe tuned to the endoplasmic reticulum tracks changes in luminal H2O2.

    Science.gov (United States)

    Melo, Eduardo Pinho; Lopes, Carlos; Gollwitzer, Peter; Lortz, Stephan; Lenzen, Sigurd; Mehmeti, Ilir; Kaminski, Clemens F; Ron, David; Avezov, Edward

    2017-03-27

    The fate of hydrogen peroxide (H 2 O 2 ) in the endoplasmic reticulum (ER) has been inferred indirectly from the activity of ER-localized thiol oxidases and peroxiredoxins, in vitro, and the consequences of their genetic manipulation, in vivo. Over the years hints have suggested that glutathione, puzzlingly abundant in the ER lumen, might have a role in reducing the heavy burden of H 2 O 2 produced by the luminal enzymatic machinery for disulfide bond formation. However, limitations in existing organelle-targeted H 2 O 2 probes have rendered them inert in the thiol-oxidizing ER, precluding experimental follow-up of glutathione's role in ER H 2 O 2 metabolism. Here we report on the development of TriPer, a vital optical probe sensitive to changes in the concentration of H 2 O 2 in the thiol-oxidizing environment of the ER. Consistent with the hypothesized contribution of oxidative protein folding to H 2 O 2 production, ER-localized TriPer detected an increase in the luminal H 2 O 2 signal upon induction of pro-insulin (a disulfide-bonded protein of pancreatic β-cells), which was attenuated by the ectopic expression of catalase in the ER lumen. Interfering with glutathione production in the cytosol by buthionine sulfoximine (BSO) or enhancing its localized destruction by expression of the glutathione-degrading enzyme ChaC1 in the lumen of the ER further enhanced the luminal H 2 O 2 signal and eroded β-cell viability. A tri-cysteine system with a single peroxidatic thiol enables H 2 O 2 detection in oxidizing milieux such as that of the ER. Tracking ER H 2 O 2 in live pancreatic β-cells points to a role for glutathione in H 2 O 2 turnover.

  1. Optical imaging of green fluorescent protein markers for tracking vascular gene expression: a feasibility study in human tissue-like phantoms

    Science.gov (United States)

    Kumar, Ananda; Chen, Hunter H.; Long, Erin; Wang, Danming; Yang, Xiaoming

    2002-06-01

    Vascular gene therapy is an exciting approach to the treatment of cardiovascular diseases. However, to date, there are no imaging modalities available for non-invasive detection of vascular gene expression. We have developed an optical imaging method to track vascular gene expression by detecting fluorescent signals emitted from arterial walls following gene transfer. To investigate the feasibility of this new technique, we performed experiments on a set of human tissue-like phantoms using a common biological marker in gene therapy, the green fluorescent protein (GFP). The phantoms were constructed to mimic the arterial geometry beneath a tissue layer. Human smooth muscle cells transfected with GFP were embedded in a capillary tube in the phantom. Monte Carlo modeling of the phantom experiment was performed to optimize the performance of the optical imaging system. We compared the fluence rates among three types of light beams, including ring beam, Gaussian beam, and flat beam. The results showed that our optical imaging system was able to detect fluorescent signals up to 5-mm depth in the phantom, and that flat beam geometry would produce the optimum fluorescence remittance. This study provides valuable insights for improvements to the optical imaging system and refinement of the new technique to non-invasively detect/track vascular gene expression.

  2. Stabilization

    Directory of Open Access Journals (Sweden)

    Muhammad H. Al-Malack

    2016-07-01

    Full Text Available Fuel oil flyash (FFA produced in power and water desalination plants firing crude oils in the Kingdom of Saudi Arabia is being disposed in landfills, which increases the burden on the environment, therefore, FFA utilization must be encouraged. In the current research, the effect of adding FFA on the engineering properties of two indigenous soils, namely sand and marl, was investigated. FFA was added at concentrations of 5%, 10% and 15% to both soils with and without the addition of Portland cement. Mixtures of the stabilized soils were thoroughly evaluated using compaction, California Bearing Ratio (CBR, unconfined compressive strength (USC and durability tests. Results of these tests indicated that stabilized sand mixtures could not attain the ACI strength requirements. However, marl was found to satisfy the ACI strength requirement when only 5% of FFA was added together with 5% of cement. When the FFA was increased to 10% and 15%, the mixture’s strength was found to decrease to values below the ACI requirements. Results of the Toxicity Characteristics Leaching Procedure (TCLP, which was performed on samples that passed the ACI requirements, indicated that FFA must be cautiously used in soil stabilization.

  3. Technical Description of Radar and Optical Sensors Contributing to Joint UK-Australian Satellite Tracking, Data-fusion and Cueing Experiment

    Science.gov (United States)

    Eastment, J.; Ladd, D.; Donnelly, P.; Ash, A.; Harwood, N.; Ritchie, I.; Smith, C.; Bennett, J.; Rutten, M.; Gordon, N.

    2014-09-01

    DSTL, DSTO, EOS and STFC have recently participated in a campaign of co-ordinated observations with both radar and optical sensors in order to demonstrate and to refine methodologies for orbit determination, data fusion and cross-sensor cueing. The experimental programme is described in detail in the companion paper by Harwood et al. At the STFC Chilbolton Observatory in Southern England, an S-band radar on a 25 m diameter fully-steerable dish antenna was used to measure object range and radar cross-section. At the EOS Space Systems facility on Mount Stromlo, near Canberra, Australia, an optical system comprising a 2 m alt / az observatory, with Coude path laser tracking at 400W power, was used to acquire, lock and laser track the cued objects, providing accurate orbit determinations for each. DSTO, located at Edinburgh, Australia, operated an optical system consisting of a small commercial telescope and mount, measuring the direction to the objects. Observation times were limited to the evening solar terminator period. Data from these systems was processed independently, using DSTL-developed and DSTO / EOS-developed algorithms, to perform orbit determination and to cross-cue: (i) the radar, based on the optical measurements; (ii) the optical system, based on the radar measurements; and (iii) the radar, using its own prior observations (self-cueing). In some cases, TLEs were used to initialise the orbit determination process; in other cases, the cues were derived entirely from sensor data. In all 3 scenarios, positive results were obtained for a variety of satellites in low earth orbits, demonstrating the feasibility of the different cue generation techniques. The purpose of this paper is to describe the technical characteristics of the radar and optical systems used, the modes of operation employed to acquire the observations, and details of the parameters measured and the data formats.

  4. Solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Medeiros, J.A.; Carvalho, M.L.C.P. de

    1992-12-01

    Solid state nuclear track detectors (SSNTD) are dielectric materials, crystalline or vitreous, which registers tracks of charged nuclear particles, like alpha particles or fission fragments. Chemical etching of the detectors origin tracks that are visible at the optical microscope: track etching rate is higher along the latent track, where damage due to the charged particle increase the chemical potential, and etching rate giving rise to holes, the etched tracks. Fundamental principles are presented as well as some ideas of main applications. (author)

  5. Utility of optical facial feature and arm movement tracking systems to enable text communication in critically ill patients who cannot otherwise communicate.

    Science.gov (United States)

    Muthuswamy, M B; Thomas, B N; Williams, D; Dingley, J

    2014-09-01

    Patients recovering from critical illness especially those with critical illness related neuropathy, myopathy, or burns to face, arms and hands are often unable to communicate by writing, speech (due to tracheostomy) or lip reading. This may frustrate both patient and staff. Two low cost movement tracking systems based around a laptop webcam and a laser/optical gaming system sensor were utilised as control inputs for on-screen text creation software and both were evaluated as communication tools in volunteers. Two methods were used to control an on-screen cursor to create short sentences via an on-screen keyboard: (i) webcam-based facial feature tracking, (ii) arm movement tracking by laser/camera gaming sensor and modified software. 16 volunteers with simulated tracheostomy and bandaged arms to simulate communication via gross movements of a burned limb, communicated 3 standard messages using each system (total 48 per system) in random sequence. Ten and 13 minor typographical errors occurred with each system respectively, however all messages were comprehensible. Speed of sentence formation ranged from 58 to 120s with the facial feature tracking system, and 60-160s with the arm movement tracking system. The average speed of sentence formation was 81s (range 58-120) and 104s (range 60-160) for facial feature and arm tracking systems respectively, (Pcommunication aids in patients in general and burns critical care units who cannot communicate by conventional means, due to the nature of their injuries. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  6. Tracking On-Orbit Stability of the Response Versus Scan Angle for the S-NPP VIIRS Reflective Solar Bands

    Science.gov (United States)

    Wu, Aisheng; Xiong, Xiaoxiong; Cao, Changyong

    2016-01-01

    The Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi NPP (National Polar-orbiting Partnership) satellite (http:npp.gsfc.nasa.govviirs.html) has been in operation for nearly five years. The onboard calibration of the VIIRS reflective solar bands (RSB) relies on a solar diffuser (SD) located at a fixed scan angle and a solar diffuser stability monitor (SDSM). The VIIRS response versus scan angle (RVS) was characterized prelaunch in ambient conditions and is currently used to determine the on-orbit response for all scan angles relative to the SD scan angle. Since the RVS is vitally important to the quality of calibrated level 1B products, it is important to monitor its on-orbit stability. In this study, the RVS stability is examined based on reflectance trends collected from 16-day repeatable orbits over pre-selected pseudo-invariant desert sites in Northern Africa. These trends nearly cover the entire Earth view scan range so that any systematic drifts in the scan angle direction would indicate a change in RVS. This study also compares VIIRS RVS on-orbit stability results with those from both Aqua and Terra MODIS over the first four years of mission for a few selected bands, which provides further information on potential VIIRS RVS on-orbit changes.

  7. Kapitza stabilization of a repulsive Bose-Einstein condensate in an oscillating optical lattice

    Science.gov (United States)

    Martin, J.; Georgeot, B.; Guéry-Odelin, D.; Shepelyansky, D. L.

    2018-02-01

    We show that the Kapitza stabilization can occur in the context of nonlinear quantum fields. Through this phenomenon, an amplitude-modulated lattice can stabilize a Bose-Einstein condensate with repulsive interactions and prevent the spreading for long times. We present a classical and quantum analysis in the framework of Gross-Pitaevskii equation, specifying the parameter region where stabilization occurs. Effects of nonlinearity lead to a significant increase of the stability domain compared with the classical case. Our proposal can be experimentally implemented with current cold atom settings.

  8. Flight-Like Optical Reference Cavity for GRACE Follow-On Laser Frequency Stabilization

    Science.gov (United States)

    Folkner, W. M.; deVine, G.; Klipstein, W. M.; McKenzie, K.; Spero, R.; Thompson, R.; Yu, N.; Stephens, M.; Leitch, J.; Pierce, R.; hide

    2011-01-01

    We describe a prototype optical cavity and associated optics that has been developed to provide a stable frequency reference for a future space-based laser ranging system. This instrument is being considered for inclusion as a technology demonstration on the recently announced GRACE follow-on mission, which will monitor variations in the Earth's gravity field.

  9. Effect of stabilizer on optical and structural properties of MgO thin ...

    Indian Academy of Sciences (India)

    2016-08-26

    Aug 26, 2016 ... MgO; thin film; sol–gel; stabilizer. ... SEM micrographs show that a homogenous and crack-free film can be prepared at 500 °C and addition of stabilizer causes an increase in packing ... Department of Physics, Faculty of Science, University of Guilan, Namjoo Avenue, P.O. Box 413351914, Rasht, Iran ...

  10. Structure, optical properties and thermal stability of HfErO films deposited by simultaneous RF and VHF magnetron sputtering

    International Nuclear Information System (INIS)

    Zhang, H.Y.; He, H.J.; Zhang, Z.; Jin, C.G.; Yang, Y.; Wang, Y.Y.; Ye, C.; Zhuge, L.J.; Wu, X.M.

    2015-01-01

    HfErO films are deposited on Si substrates by simultaneous radio frequency (RF) and very high frequency (VHF) magnetron sputtering technique. The content of the doped ingredient of Er and the body composition of HfO x are, respectively, controlled through the VHF and RF powers. Low content of Er doping in the HfErO films can be achieved, because the VHF source of 27.12 MHz has higher ion energy and lower ion flux than the RF source resulting in low sputtering rate in the magnetron sputtering system. The structure, optical properties and thermal stability of the HfErO films are investigated in this work. Results show that the doped content of Er is independently controlled by the VHF power. The oxygen vacancies are created by the Er incorporation. The hafnium in the HfErO films forms mixed valence of Hf 2+ and Hf 4+ . The HfErO films are composed with the structures of HfO 2 , HfO and ErO x , which can be optimized through the VHF power. At high VHF power, the Hf-Er-O bonds are formed, which demonstrates that the Er atoms are doped into the lattice of HfO 2 in the HfErO films. The HfErO films have bad thermal stability as the crystallization temperature decreases from 900 to 800 C. After thermal annealing, cubic phase of HfO 2 are stabilized, which is ascribed to the oxygen vacancies creation by the Er incorporation. The optical properties such as the refractive index and the optical band gap of the HfErO films are optimized by the VHF power. (orig.)

  11. Light backscatter fiber optic sensor: a new tool for predicting the stability of pork emulsions containing antioxidative potato protein hydrolysate.

    Science.gov (United States)

    Nieto, Gema; Xiong, Youling L; Payne, Fred; Castillo, Manuel

    2015-02-01

    The objective of this study was to determine whether light backscatter response from fresh pork meat emulsions is correlated to final product stability indices. A specially designed fiber optic measurement system was used in combination with a miniature fiber optic spectrometer to determine the intensity of light backscatter within the wavelength range 300-1100 nm (UV/VIS/NIR) at different radial distances (2, 2.5 and 3mm) with respect to the light source in pork meat emulsions with two fat levels (15%, 30%) and two levels (0, 2.5%) of the natural antioxidant hydrolyzed potato protein (HPP). Textural parameters (hardness, deformability, cohesiveness and breaking force), cooking loss, TBARS (1, 2, 3, and 7 days of storage at 4 °C) and CIELAB color coordinates of cooked emulsions were measured. The light backscatter was directly correlated with cooking losses, color, breaking force and TBARS. The optical configuration proposed would compensate for the emulsion heterogeneity, maximizing the existing correlation between the optical signal and the emulsion quality metrics.

  12. Simultaneous three-dimensional tracking of individual signals from multi-trap optical tweezers using fast and accurate photodiode detection.

    Science.gov (United States)

    Ott, Dino; Nader, S; Reihani, S; Oddershede, Lene B

    2014-09-22

    Multiple-beam optical traps facilitate advanced trapping geometries and exciting discoveries. However, the increased manipulation capabilities come at the price of more challenging position and force detection. Due to unrivaled bandwidth and resolution, photodiode based detection is preferred over camera based detection in most single/dual-beam optical traps assays. However, it has not been trivial to implement photodiode based detection for multiple-beam optical traps. Here, we present a simple and efficient method based on spatial filtering for parallel photodiode detection of multiple traps. The technique enables fast and accurate 3D force and distance detection of multiple objects simultaneously manipulated by multiple-beam optical tweezers.

  13. Two-way time transfer via optical fiber providing subpicosecond precision and high temperature stability

    Czech Academy of Sciences Publication Activity Database

    Kodet, J.; Pánek, Petr; Procházka, I.

    2015-01-01

    Roč. 53, č. 1 (2015), s. 18-26 ISSN 0026-1394 Institutional support: RVO:67985882 Keywords : optical fiber * time transfer * TWOTT Subject RIV: JB - Sensors, Measurment, Regulation Impact factor: 2.500, year: 2015

  14. Two-way time transfer via optical fiber providing subpicosecond precision and high temperature stability

    Czech Academy of Sciences Publication Activity Database

    Kodet, J.; Pánek, Petr; Procházka, I.

    2016-01-01

    Roč. 53, č. 1 (2016), s. 18-26 ISSN 0026-1394 Institutional support: RVO:67985882 Keywords : TWOTT * Time transfer * Optical fiber Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 3.411, year: 2016

  15. Colloidal photonic glass for electro-optic display stabilized with potassium persulfate (KPS) in polar solvent

    Science.gov (United States)

    Lee, Hye-Young; Kim, Young-Seok; Yi, Gi-Ra

    2016-04-01

    We introduced carbon-shell with potassium persulfate structure to modify the repulsive force between particles and minimize scattered light. The reflected structural color varied from blue to red and showed high color purity with high cycle stability.

  16. Spectrometer for Sky-Scanning Sun-Tracking Atmospheric Research (4STAR: Instrument Technology

    Directory of Open Access Journals (Sweden)

    Yohei Shinozuka

    2013-08-01

    Full Text Available The Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR combines airborne sun tracking and sky scanning with diffraction spectroscopy to improve knowledge of atmospheric constituents and their links to air-pollution/climate. Direct beam hyper-spectral measurement of optical depth improves retrievals of gas constituents and determination of aerosol properties. Sky scanning enhances retrievals of aerosol type and size distribution. 4STAR measurements will tighten the closure between satellite and ground-based measurements. 4STAR incorporates a modular sun-tracking/ sky-scanning optical head with fiber optic signal transmission to rack mounted spectrometers, permitting miniaturization of the external optical head, and future detector evolution. Technical challenges include compact optical collector design, radiometric dynamic range and stability, and broad spectral coverage. Test results establishing the performance of the instrument against the full range of operational requirements are presented, along with calibration, engineering flight test, and scientific field campaign data and results.

  17. Study of gamma irradiation effects on the etching and optical properties of CR-39 solid state nuclear track detector and its application to uranium assay in soil samples

    International Nuclear Information System (INIS)

    Amol Mhatre; Kalsi, P.C.

    2011-01-01

    The gamma irradiation effects in the dose range of 2.5-43.0 Mrad on the etching and optical characteristics of CR-39 solid state nuclear track detector (SSNTD) have been studied by using etching and UV-Visible spectroscopic techniques. From the measured bulk etch rates at different temperatures, the activation energies for bulk etching at different doses have also been determined. It is seen that the bulk etch rates increase and the activation energies for bulk etching decrease with the increase in gamma dose. The optical band gaps of the unirradiated and the gamma -irradiated detectors determined from the UV-Visible spectra were found to decrease with the increase in gamma dose. These results have been explained on the basis of scission of the detector due to gamma irradiation. The present studies can be used for the estimation of gamma dose in the range of 2.5-43.0 Mrad and can also be used for estimating track registration efficiency in the presence of gamma dose. The CR-39 detector has also been applied for the assay of uranium in some soil samples of Jammu city. (author)

  18. MR-guided breast biopsy and hook wire marking using a low-field (0.23 T) scanner with optical instrument tracking

    International Nuclear Information System (INIS)

    Blanco Sequeiros, Roberto; Reinikainen, Heli; Blanco Sequeiros, Andreas M.; Ojala, Risto; Paeaekkoe, Eija; Tervonen, Osmo; Vaara, Teuvo

    2007-01-01

    The purpose of this study was to evaluate the technical feasibility of MR-guided percutaneous breast biopsy (LCNB) and breast hook wire marking in a low-field (0.23 T) MRI system with optical instrument tracking. MR-guided core biopsy and/or hook wire marking was performed on 13 lesions observable at MR imaging only. Seven breast LCNBs and 10 hook wire markings were performed under MR guidance on 11 patients. The diagnosis was confirmed by excision biopsy or mastectomy in 12 lesions and with histopathological and cytological diagnosis and 12-month clinical follow-up in one lesion. All lesions seen in the high-field scanner were also successfully identified and targeted in the low-field scanner. The following procedures were typically technically successful. There were difficulties due to unsatisfactory functioning of some core biopsy guns. Detailed description of low-field MR guidance and optical tracking in breast biopsies is provided. The procedure seems accurate and safe and provides means to obtain a histological diagnosis of a breast lesion only seen with MRI. The low-field biopsy system is comparable to the high-field MRI system. MR-compatible biopsy guns need to be improved. (orig.)

  19. Few-layer antimonene decorated microfiber: ultra-short pulse generation and all-optical thresholding with enhanced long term stability

    Science.gov (United States)

    Song, Yufeng; Liang, Zhiming; Jiang, Xiantao; Chen, Yunxiang; Li, Zhongjun; Lu, Lu; Ge, Yanqi; Wang, Ke; Zheng, Jilin; Lu, Shunbin; Ji, Jianhua; Zhang, Han

    2017-12-01

    Antimonene, a new type of mono/few-layer two-dimensional (2D) mono-elemental material purely consisting of antimony similar as graphene and phosphorene, has been theoretically predicted with excellent optical response and enhanced stability. Herein, we experimentally investigated the broadband nonlinear optical response of highly stable few-layer antimonene (FLA) by performing an open-aperture Z-scan laser measurement. Thanks to the direct bandgap and resonant absorption at the telecommunication band, we demonstrated the feasibility of FLA-decorated microfiber not only as an optical saturable absorber for ultrafast photonics operation, but also as a stable all-optical pulse thresholder that can effectively suppress the transmission noise, boost the signal-to-noise ratio (SNR), and reshape the deteriorated input signal. Our findings, as the first prototypic device of absorption of antimonene, might facilitate the development of antimonene-based optical communication technologies towards high stability and practical applications in the future.

  20. Optical measurements of soot size and number density in a complex flow, swirl-stabilized combustor

    Science.gov (United States)

    Samuelsen, G. S.; Wood, C. P.; Jackson, T. A.

    1984-01-01

    In-flame optical measurements of soot particulates in a turbulent, recirculating (i.e., complex flow) model laboratory combustor are described. A nonintrusive optical probe based on large angle (60 deg, 20 deg) intensity ratio scattering was used to yield a point measurement of particulate in the size range of 0.08 to 0.38 micrometers. The performance of the optical technique was evaluated, and an exploratory assessment of the spatial distribution of soot was conducted with attention to fuel molecular structure, fuel loading, and a smoke-suppressant additive (ferrocene). Isooctane and mixtures of isooctane with various ring and aromatic compounds blended to yield the smoke point of a JP-8 stock were prevaporized and introduced through a hollow cone nozzle. The addition of ring compounds to the base isooctane substantially changed the distribution of soot and increased the overall emission by 300%. The production of soot was substantially reduced by a decrease in fuel loading, and marginally reduced or not affected by the additive depending on fuel structure. The optical technique is a potentially powerful tool for providing the experimental evidence necessary to understand the processes of soot formation and burnout in complex flows typical of gas turbine combustors. However, scanning electron micrographs of extracted sample established that the technique is limited to the large particle wing of the soot size distribution, and optical and electronic processing can induce biasing and uncertainties which must be understood and controlled before the potential of the technique can be fulfilled.

  1. Comportamiento de una pista experimental de pavimento flexible con base estabilizada con cal Behavior of an experimental track of flexible pavement with lime stabilized base

    Directory of Open Access Journals (Sweden)

    César Augusto Hidalgo Montoya

    2010-01-01

    Full Text Available En este trabajo se presentan resultados de una investigación realizada para determinar las propiedades de deformabilidad de bases estabilizadas con cal a partir de ensayos de campo no destructivos. Se realizaron ensayos de placa estática y viga Benkelman en un tramo de prueba de pavimento flexible de 70m de longitud. Se usaron diferentes mezclas de suelo-cal y varios espesores de la estructura para evaluar el comportamiento del pavimento. A partir de los resultados de estos ensayos fueron realizados retroanálisis del comportamiento del pavimento. El método de los elementos finitos y el modelo elástico de esfuerzos y deformaciones en sistema de capas múltiples se usaron en los retroanálisis para estimar los módulos de deformabilidad de la base estabilizada con cal. Se concluye que la adición de cal mejora sustancialmente las propiedades de los pavimentos evaluados.This paper presents results of a research carried out to determine the proprieties of deformation of lime stabilized bases using non destructive field tests. Static plate tests and Benkelman beam tests were made on an experimental track of flexible pavement of 70 m length. Several mixtures of soil-lime and several thickness of the stabilized base were used to evaluate the behavior of the pavement. With the results of these tests, back analysis of the behavior of pavement was carried out. The finite elements method and the elastic stress and strain in a multi layers system were used to estimate the deformation modulus of the lime stabilized bases. It is concluded that the lime addition significantly improves the properties of evaluated pavements.

  2. Longitudinal evaluation of simulated toothbrushing on the roughness and optical stability of microfilled, microhybrid and nanofilled resin-based composites.

    Science.gov (United States)

    da Silva, Eduardo Moreira; Dória, Juliana; da Silva, Juliana de Jesus Rodrigues; Santos, Guilherme Vinícius; Guimarães, José Guilherme Antunes; Poskus, Laiza Tatiana

    2013-11-01

    The aim of this study was to evaluate the influence of simulated toothbrushing over ten weeks on the roughness and optical stability (colour, translucency and gloss) of microfilled - Mf (Durafil VS), microhybrid - Mh (Empress Direct) and nanofilled - Nf (Z 350) resin-based composites (RBC). The roughness, colour, translucency and gloss of each RBC were measured before and after storage in distilled water (DW) and propionic acid (PA) for ten weeks. The specimens were removed from the media each week, submitted to toothbrushing simulation and the properties measured. The obtained data were analyzed using a multifactor analysis of variance (MANOVA) and Tukey's HSD test (α=0.05). The roughness significantly increased after ten weeks for the three RBCs (p0.05). Only Mf and Nf immersed in DW and Mh immersed in PA presented a change in colour after ten weeks (p0.05). Only Mh immersed in DW presented gloss stability after ten weeks (p>0.05). Toothbrushing increased the roughness and diminished the gloss of the three RBCs. The translucency was not influenced by the toothbrushing. The immersion in propionic acid produced lower alterations in colour than did immersion in distilled water. In general, the three RBCs presented similar optical behaviours after toothbrushing over ten weeks. Thus, it is possible that anterior restorations produced with these materials will not present perceptible differences over time. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Design and validation of an open-source library of dynamic reference frames for research and education in optical tracking.

    Science.gov (United States)

    Brown, Alisa; Uneri, Ali; Silva, Tharindu De; Manbachi, Amir; Siewerdsen, Jeffrey H

    2018-04-01

    Dynamic reference frames (DRFs) are a common component of modern surgical tracking systems; however, the limited number of commercially available DRFs poses a constraint in developing systems, especially for research and education. This work presents the design and validation of a large, open-source library of DRFs compatible with passive, single-face tracking systems, such as Polaris stereoscopic infrared trackers (NDI, Waterloo, Ontario). An algorithm was developed to create new DRF designs consistent with intra- and intertool design constraints and convert to computer-aided design (CAD) files suitable for three-dimensional printing. A library of 10 such groups, each with 6 to 10 DRFs, was produced and tracking performance was validated in comparison to a standard commercially available reference, including pivot calibration, fiducial registration error (FRE), and target registration error (TRE). Pivot tests showed calibration error [Formula: see text], indistinguishable from the reference. FRE was [Formula: see text], and TRE in a CT head phantom was [Formula: see text], both equivalent to the reference. The library of DRFs offers a useful resource for surgical navigation research and could be extended to other tracking systems and alternative design constraints.

  4. Laser beam uniformity and stability using homogenizer-based fiber optic launch method: square core fiber delivery

    Science.gov (United States)

    Lizotte, Todd E.

    2011-03-01

    Over the years, technological achievements within the laser medical diagnostic, treatment, and therapy markets have led to ever increasing requirements for greater control of critical laser beam parameters. Increased laser power/energy stabilization, temporal and spatial beam shaping and flexible laser beam delivery systems with ergonomic focusing or imaging lens systems are sought by leading medical laser system producers. With medical procedures that utilize laser energy, there is a constant emphasis on reducing adverse effects that come about by the laser itself or its optical system, but even when these variables are well controlled the medical professional will still need to deal with the multivariate nature of the human body. Focusing on the variables that can be controlled, such as accurate placement of the laser beam where it will expose a surface being treated as well as laser beam shape and uniformity is critical to minimizing adverse conditions. This paper covers the use of fiber optic beam delivery as a means of defining the beam shape (intensity/power distribution uniformity) at the target plane as well as the use of fiber delivery as a means to allow more flexible articulation of the laser beam over the surface being treated. The paper will present a new concept of using a square core fiber beam delivery design utilizing a unique micro lens array (MLA) launch method that improves the overall stability of the system, by minimizing the impact of the laser instability. The resulting performance of the prototype is presented to demonstrate its stability in comparison to simple lens launch techniques, with an emphasis on homogenization and articulated fiber delivery.

  5. First-Principles Investigation of Phase Stability, Electronic Structure and Optical Properties of MgZnO Monolayer

    Directory of Open Access Journals (Sweden)

    Changlong Tan

    2016-10-01

    Full Text Available MgZnO bulk has attracted much attention as candidates for application in optoelectronic devices in the blue and ultraviolet region. However, there has been no reported study regarding two-dimensional MgZnO monolayer in spite of its unique properties due to quantum confinement effect. Here, using density functional theory calculations, we investigated the phase stability, electronic structure and optical properties of MgxZn1−xO monolayer with Mg concentration x range from 0 to 1. Our calculations show that MgZnO monolayer remains the graphene-like structure with various Mg concentrations. The phase segregation occurring in bulk systems has not been observed in the monolayer due to size effect, which is advantageous for application. Moreover, MgZnO monolayer exhibits interesting tuning of electronic structure and optical properties with Mg concentration. The band gap increases with increasing Mg concentration. More interestingly, a direct to indirect band gap transition is observed for MgZnO monolayer when Mg concentration is higher than 75 at %. We also predict that Mg doping leads to a blue shift of the optical absorption peaks. Our results may provide guidance for designing the growth process and potential application of MgZnO monolayer.

  6. LHC optics determination with proton tracks measured in the CT-PPS detectors in 2016, before TS2

    CERN Document Server

    Nemes, F

    2017-01-01

    Novel optics estimation methods have been developed for the CMS-TOTEM Precision Proton Spectrometer (CT-PPS), in order to determine the horizontal dispersion function $D_{x}$ and the orbit between IP5 and the Roman Pot detectors. The tools have been successfully applied at $\\sqrt{s} = $13 TeV collision energy and $\\beta^{*} = $0.4 m optics with $\\alpha = 370\\,\\mu$rad horizontal crossing angle (settings valid in 2016 before Technical Stop 2 - TS2).

  7. Potted fiber optic sensor coil by novel adhesives for high-stability FOG

    Science.gov (United States)

    Bi, Congzhi; Sun, Guofei; Wu, Yanji; Zhao, Keyong

    2011-08-01

    A sensor coil for a fiber optic gyroscope is fabricated and potted by a novel adhesive. The kind of adhesive can match to the outer jacket of polarization maintaining fiber (PMF) to improve the potting uniformity of the whole coil, so that it could contribute to reduce the temperature-induced strain and the strain differential between the clockwise and counterclockwise-wound portions of a symmetrically-wound fiber coil, i.e. temperature-dependent Shupe stress effect. The adhesive is a compound comprising acrylate and polyurethane, which can avoid the non-wetting problem resulting from the two different types of compounds. The adhesive is a low viscosity system which exhibits a prolonged work life, an adjustable hardness. Specially, the potting compound with a low glass transition temperature (Tg), down to the lower temperature -60°C, remain stable modulus during thermal cycling between -40°C and 60°C. The potted fiber optic sensor coil with a smooth surface is clear and regular due to the completely curable adhesive. The extinction coefficient of the fiber optic sensor coil can reflect the additional stress produced by the adhesives through comparing before potting with after potting. the potted fiber optic sensor coil shows excellent bias characteristics and temperature performance.

  8. Optics

    CERN Document Server

    Mathieu, Jean Paul

    1975-01-01

    Optics, Parts 1 and 2 covers electromagnetic optics and quantum optics. The first part of the book examines the various of the important properties common to all electromagnetic radiation. This part also studies electromagnetic waves; electromagnetic optics of transparent isotropic and anisotropic media; diffraction; and two-wave and multi-wave interference. The polarization states of light, the velocity of light, and the special theory of relativity are also examined in this part. The second part is devoted to quantum optics, specifically discussing the classical molecular theory of optical p

  9. Study of the optical properties and the carbonaceous clusters in thermally-annealed CR-39 and Makrofol-E polymer-based solid-state nuclear track detectors

    International Nuclear Information System (INIS)

    El Ghazaly, M.

    2012-01-01

    The induced modifications in the optical properties of CR-39 and Makrofol-E polymer-based solid state nuclear track detectors were investigated after thermal annealing at a temperature of 200 .deg. C for different durations. The optical properties were studied using an UV-visible spectrophotometer. From the UV-visible spectra, the direct and the indirect optical band gaps, Urbach's energies, and the number of carbon atoms in a cluster were determined. The absorbance of CR-39 plastic detector was found to decrease with increasing annealing time while the absorbance of Makrofol-E decreased with increasing annealing time. The width of the tail of localized states in the band gap ΔE was evaluated with the Urbach method. The optical energy band gaps were obtained from the direct and the indirect allowed transitions in K-space. Both of the direct and the indirect band gaps of the annealed CR-39 detector decrease with increasing annealing time while in Makrofol-E, they decreased after an annealing time of 15 minute and then showed no remarkable changes for a prolonged annealing times. Urbach's energy decreased significantly for both CR-39 and Makrofol-E with increasing annealing time. The number of carbon atoms in a cluster increased in the CR-39 detector with increasing annealing time while it decreased with increasing annealing time for Makrofol-E. We may conclude that the CR-39 detector undergoes greater modifications than the Makrofol-E detector upon thermal annealing at 200 .deg. C. In conclusion, the induced modifications in the optical properties of CR-39 and Makrofol-E are correlated with the temperature and the duration of annealing.

  10. Effect of stabilizer on optical and structural properties of MgO thin ...

    Indian Academy of Sciences (India)

    The stirring was continued for 1 h at room temperature to yield a clear and homogeneous solution. We tested four different kinds of stabilizers: monoethanolamine (MEA), diethanolamine (DEA), triethanolamine (TEA) and acety- lacetone (ACAC). By adding TEA we could not get a clear solution. The sol containing TEA was ...

  11. Controlling the stability of nonlinear optical modes via electromagnetically induced transparency

    Science.gov (United States)

    Zhang, Kun; Liang, Yi-zeng; Lin, Ji; Li, Hui-jun

    2018-02-01

    We propose a scheme to generate and stabilize the high-dimensional spatial solitons via electromagnetically induced transparency (EIT). The system we consider is a resonant atomic ensemble having Λ configuration. We illustrate that under EIT conditions the equation satisfied by the probe field envelope is reduced to a saturable nonlinear Schrödinger equation with the trapping potential, provided by a far-detuned laser field and a random magnetic field. We present high-dimensional soliton solutions exhibiting many interesting characteristics, including diversity (i.e., many different types of soliton solutions can be found, including bright, ring multipole bright, ring multipole defect mode, multiring bright, multiring defect mode, and vortices solitons), the phase transition between bright soliton and higher-order defect modes (i.e., the phase transition can be realized by controlling the nonlinear coefficient or the intensity of the trapping potential), and stability (i.e., various solitons can be stabilized by the Gaussian potential provided by the far detuned laser field, or the random potential provided by the magnetic field). We also find that some solitons are the extension of the linear eigenmode, whereas others entirely derive from the role of nonlinearity. Compared with previous studies, we not only show the diverse soliton solutions in the same system but also find the boundary of the phase transition for the type of solitons. In addition, we present the possibility of using the random potential to stabilize various solitons and vortices.

  12. Image motion compensation by area correlation and centroid tracking of solar surface features

    Science.gov (United States)

    Nein, M. E.; Mcintosh, W. R.; Cumings, N. P.

    1983-01-01

    An experimental solar correlation tracker was tested and evaluated on a ground-based solar magnetograph. Using sunspots as fixed targets, tracking error signals were derived by which the telescope image was stabilized against wind induced perturbations. Two methods of stabilization were investigated; mechanical stabilization of the image by controlled two-axes motion of an active optical element in the telescope beam, and electronic stabilization by biasing of the electron scan in the recording camera. Both approaches have demonstrated telescope stability of about 0.6 arc sec under random perturbations which can cause the unstabilized image to move up to 120 arc sec at frequencies up to 30 Hz.

  13. Concentration-dependent optical properties of TGA stabilized CdTe Quantum dots synthesized via the single injection hydrothermal method in the ambient environment

    Science.gov (United States)

    Jai Kumar, B.; Mahesh, H. M.

    2017-04-01

    Thioglycolic acid (TGA) stabilized aqueous CdTe Quantum dots (QDs) were synthesized using a facile, cost efficient Single Injection Hydrothermal (SIH) method. The complete preparation of precursors and growth of QDs was carried out in the ambient environment without inter gas protection. The Cadmium and Tellurium precursors were prepared from cadmium nitrate and elemental tellurium powder with sodium borohydride as reducing agent respectively. A systematic investigation was carried out in order to study the effect of 0.04M and 0.08M TGA concentration on ease synthesis, stability and size-tunable optical absorbance, bandgap, photoluminescence (PL) and Quantum yield (QY) of CdTe QDs. The Structure of QDs was verified by XRD and optical properties by absorbance and PL spectra. Experimental results revealed that the 0.08M TGA QDs possess good chemical and optical stability with high luminescence and decent QY, ready to use in optoelectronics, photovoltaic and biological application.

  14. Dynamic stability with the disturbance-free payload architecture as applied to the Large UV/Optical/Infrared (LUVOIR) Mission

    Science.gov (United States)

    Dewell, Larry D.; Tajdaran, Kiarash; Bell, Raymond M.; Liu, Kuo-Chia; Bolcar, Matthew R.; Sacks, Lia W.; Crooke, Julie A.; Blaurock, Carl

    2017-09-01

    The need for high payload dynamic stability and ultra-stable mechanical systems is an overarching technology need for large space telescopes such as the Large Ultraviolet / Optical / Infrared (LUVOIR) Surveyor. Wavefront error stability of less than 10 picometers RMS of uncorrected system WFE per wavefront control step represents a drastic performance improvement over current space-based telescopes being fielded. Previous studies of similar telescope architectures have shown that passive telescope isolation approaches are hard-pressed to meet dynamic stability requirements and usually involve complex actively-controlled elements and sophisticated metrology. To meet these challenging dynamic stability requirements, an isolation architecture that involves no mechanical contact between telescope and the host spacecraft structure has the potential of delivering this needed performance improvement. One such architecture, previously developed by Lockheed Martin called Disturbance Free Payload (DFP), is applied to and analyzed for LUVOIR. In a noncontact DFP architecture, the payload and spacecraft fly in close proximity, and interact via non-contact actuators to allow precision payload pointing and isolation from spacecraft vibration. Because disturbance isolation through non-contact, vibration isolation down to zero frequency is possible, and high-frequency structural dynamics of passive isolators are not introduced into the system. In this paper, the system-level analysis of a non-contact architecture is presented for LUVOIR, based on requirements that are directly traceable to its science objectives, including astrophysics and the direct imaging of habitable exoplanets. Aspects of architecture and how they contribute to system performance are examined and tailored to the LUVOIR architecture and concept of operation.

  15. Accurate identification of whispering gallery mode patterns of gyrotron with stabilized electro-optic imaging system

    Science.gov (United States)

    Lee, Ingeun; Sawant, Ashwini; Choe, Mun Seok; Lee, Dong-Joon; Choi, EunMi

    2018-01-01

    The precise field pattern measurement and analysis of a typical whispering gallery mode excited in a gyrotron are important to understand the interaction physics of the gyrotron. We precisely analyzed the characteristic of a whispering gallery mode, rotating TE6,2 mode, by a photonic-assisted W-band (75-110 GHz) electro-optic imaging measurement system. The whispering gallery mode in the W-band region diverges fast in free space as it propagates from the radiation port. Therefore, scanning the field patterns of a device-under-test should be performed as close as possible to identify the device's characteristics. We successfully accomplished visualizing highly accurate field patterns of a rotating and mixed whispering gallery mode based on the measured electric field magnitude and phase by using dual optical fiber-scale electro-optic (EO) probes. We observed the distorted fields when the typical open-ended waveguide and a general EO probe were used in the extremely near-field zone, whereas a very precise field was measured in a minimally invasive way by the proposed EO probe. The measured mode patterns were quantitatively analyzed by using a cross correlation function and a mode purity equation. This work promises a way to provide accurate electric field information in the generation of the whispering gallery mode in the millimeter and submillimeter regime.

  16. SU-E-T-410: Fringe Stability and Phase Shift Measurements in a Michelson Interferometer for Optical Calorimetry

    International Nuclear Information System (INIS)

    Flores-Martinez, E; Malin, M; DeWerd, L

    2014-01-01

    Purpose: To identify the variables limiting the resolution of a Michelson interferometer used to measure phase shifts (PS) in water as part of a radiometric calorimeter. Methods: We investigated the output stability of a He-Ne laser and a laser diode. The short and long term stability of the fringe pattern in a Michelson interferometer was tested with different types of lasers, thermal insulation arrangements, damping systems and optical mounts to optimize system performance. PS were induced by electrically heating water in a 1 cm quartz cuvette located in one of the interferometer arms. The PS was calculated from fringe intensity changes and compared to a calculated PS using thermocouple-measured temperature changes in the water. Results: The intensity of the laser diode is more stable, but the gas laser’s profile is more suitable for fringe analysis and has better temporal coherence. The laser requires a warm-up time of 4 hours before its output is stabilized (SNR>95). The fringe’s stability strongly depends on the thermal insulation. When the interferometer is exposed to ambient temperature swings of 0.7 K, it is not possible to stabilize the fringe pattern. Enclosing the system in a 2.5 cm-thick Styrofoam box improves the SNR, but further insulation will be needed to increase the SNR above 50. High frequency noise is significantly reduced by damping the system.Inducing a temperature rise in water, starting at 299 K, the average temperature increase for a 2π PS is 0.29 ± 0.02 K and the proportionality constant is -21.1 ± 0.8 radians/K. This is 5.8% lower than the calculated value using the thermocouple. Conclusion: Interferometric PS measurements of temperature may provide an alternative to thermistors for water calorimetry. The resolution of the current prototype is limited by ambient temperature stability. Calculated and measured thermally-induced PS in water agreed to within 5.8%

  17. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Ninth Edition Optics: Ninth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommen

  18. Cep169, a Novel Microtubule Plus-End-Tracking Centrosomal Protein, Binds to CDK5RAP2 and Regulates Microtubule Stability.

    Directory of Open Access Journals (Sweden)

    Yusuke Mori

    Full Text Available The centrosomal protein, CDK5RAP2, is a microcephaly protein that regulates centrosomal maturation by recruitment of a γ-tubulin ring complex (γ-TuRC onto centrosomes. In this report, we identified a novel human centrosomal protein, Cep169, as a binding partner of CDK5RAP2, a member of microtubule plus-end-tracking proteins (+TIPs. Cep169 interacts directly with CDK5RAP2 through CM1, an evolutionarily conserved domain, and colocalizes at the pericentriolar matrix (PCM around centrioles with CDK5RAP2. In addition, Cep169 interacts with EB1 through SxIP-motif responsible for EB1 binding, and colocalizes with CDK5RAP2 at the microtubule plus-end. EB1-binding-deficient Cep169 abolishes EB1 interaction and microtubule plus-end attachment, indicating Cep169 as a novel member of +TIPs. We further show that ectopic expression of either Cep169 or CDK5RAP2 induces microtubule bundling and acetylation in U2OS cells, and depletion of Cep169 induces microtubule depolymerization in HeLa cells, although Cep169 is not required for assembly of γ-tubulin onto centrosome by CDK5RAP2. These results show that Cep169 targets microtubule tips and regulates stability of microtubules with CDK5RAP2.

  19. Optical properties and thermal stability of LaYbO3 ternary oxide for high-k dielectric application

    Science.gov (United States)

    Su, Wei-tao; Yang, Li; Li, Bin

    2011-01-01

    A new ternary rare oxide dielectric LaYbO3 film had been prepared on silicon wafers and quartz substrates by reactive sputtering method using a La-Yb metal target. A range of analysis techniques was performed to determine the optical band gap, thermal stability, and electrical property of the deposited samples. It was found the band gap of LaYbO3 film was about 5.8 eV. And the crystallization temperature for rapid thermal annealing (20 s) was between 900 and 950 °C. X-ray photoelectron spectroscopy results indicate the formation of the SiO2 and silicate in the interface between silicon wafer and LaYbO3 film. The dielectric constant is about 23 from the calculation of capacitance-voltage curve, which is comparable higher than previously reported La2O3 or Yb2O3 film.

  20. Absolute-frequency measurements with a stabilized near-infrared optical frequency comb from a Cr:forsterite laser

    Science.gov (United States)

    Corwin, K. L.; Thomann, I.; Dennis, T.; Fox, R. W.; Swann, W.; Curtis, E. A.; Oates, C. W.; Wilpers, G.; Bartels, A.; Gilbert, S. L.; Hollberg, L.; Newbury, N. R.; Diddams, S. A.; Nicholson, J. W.; Yan, M. F.

    2004-02-01

    A frequency comb is generated with a chromium-doped forsterite femtosecond laser, spectrally broadened in a dispersion-shifted highly nonlinear fiber, and stabilized. The resultant evenly spaced comb of frequencies ranges from 1.1 to beyond 1.8 μm. The frequency comb was referenced simultaneously to the National Institute of Standards and Technology's optical frequency standard based on neutral calcium and to a hydrogen maser that is calibrated by a cesium atomic fountain clock. With this comb we measured two frequency references in the telecommunications band: one half of the frequency of the d/f crossover transition in 87Rb at 780 nm, and the methane ν2 + 2ν3 R(8) line at 1315 nm.

  1. Quantifying the High-Speed Running and Sprinting Profiles of Elite Female Soccer Players During Competitive Matches Using an Optical Player Tracking System.

    Science.gov (United States)

    Mara, Jocelyn K; Thompson, Kevin G; Pumpa, Kate L; Morgan, Stuart

    2017-06-01

    The aim of this study was to determine the high-speed running and sprinting profiles of elite female soccer players during competitive matches using a new Optical Player Tracking system. Eight stationary video cameras were positioned at vantage points surrounding the soccer field so that when each camera view was combined, the entire field could be viewed simultaneously. After each match, an optical player tracking system detected the coordinates (x, y) of each player for every video frame. Algorithms applied to the x and y coordinates were used to determine activity variables for 12 elite female players across 7 competitive matches. Players covered 9,220-10,581 m of total distance, 1,772-2,917 m of high-speed running (3.4-5.3 m·s) distance, and 417-850 m of sprinting (>5.4 m·s) distance, with variations between positional groups (p < 0.001; partial η = 0.444-0.488). Similarly, the number of high-speed runs differed between positional groups (p = 0.002; partial η = 0.342), and a large proportion of high-speed runs (81-84%) and sprints (71-78%) were performed over distances less than 10 m. Mean time between high-speed runs (13.9 ± 4.4 seconds) and sprints (86.5 ± 38.0 seconds) varied according to playing position (p < 0.001; partial η = 0.409) and time of the match (p < 0.001; partial η = 0.113-0.310). The results of this study can be used to design match-specific conditioning drills and shows that coaches should take an individualized approach to training load monitoring according to position.

  2. Design of a high-resolution high-stability positioning mechanism for crystal optics

    International Nuclear Information System (INIS)

    Shu, D.; Toellner, T. S.; Alp, E. E.

    1999-01-01

    The authors present a novel miniature multi-axis driving structure that will allow positioning of two crystals with better than 50-nrad angular resolution and nanometer linear driving sensitivity.The precision and stability of this structure allow the user to align or adjust an assembly of crystals to achieve the same performance as does a single channel-cut crystal, so they call it an artificial channel-cut crystal. In this paper, the particular designs and specifications, as well as the test results,for a two-axis driving structure for a high-energy-resolution artificial channel-cut crystal monochromator are presented

  3. Optical and structural characterization of oleic acid-stabilized CdTe nanocrystals for solution thin film processing

    Directory of Open Access Journals (Sweden)

    Claudio Davet Gutiérrez-Lazos

    2014-06-01

    Full Text Available This work presents results of the optical and structural characterization of oleic acid-stabilized cadmium telluride nanocrystals (CdTe-NC synthesized by an organometallic route. After being cleaned, the CdTe-NC were dispersed in toluene to obtain an ink-like dispersion, which was drop-cast on glass substrate to deposit a thin film. The CdTe-NC colloidal dispersion as well as the CdTe drop-cast thin films were characterized with regard to the optical and structural properties. TEM analysis indicates that the CdTe-NC have a nearly spherical shape (3.5 nm as mean size. Electron diffraction and XRD diffraction analyses indicated the bulk-CdTe face-centered cubic structure for CdTe-NC. An additional diffraction line corresponding to the octahedral Cd3P2 was also detected as a secondary phase, which probably originates by reacting free cadmium ions with trioctylphosphine (the tellurium reducing agent. The Raman spectrum exhibits two broad bands centered at 141.6 and 162.3 cm−1, which could be associated to the TO and LO modes of cubic CdTe nanocrystals, respectively. Additional peaks located in the 222 to 324 cm−1 range, agree fairly well with the wavenumbers reported for TO modes of octahedral Cd3P2.

  4. Structural, optical and magnetic properties of Cr doped SnO{sub 2} nanoparticles stabilized with polyethylene glycol

    Energy Technology Data Exchange (ETDEWEB)

    Subramanyam, K.; Sreelekha, N. [Department of Physics, Sri Venkateswara University, Tirupati 517502 (India); Murali, G. [Department of BIN Fusion Technology and Department of Polymer-Nano Science and Technology, Chonbuk National University, Jeonju, Jeonbuk (Korea, Republic of); Reddy, D. Amaranatha [Department of Chemistry and Chemical Institute for Functional Materials, Pusan National University, Busan 609-735 (Korea, Republic of); Vijayalakshmi, R.P., E-mail: vijayaraguru@gmail.com [Department of Physics, Sri Venkateswara University, Tirupati 517502 (India)

    2014-12-01

    Pure and Cr (1, 3, 5 and 7 at%) doped SnO{sub 2} nanoparticles were synthesized in aqueous solution by a simple chemical co-precipitation method using polyethylene glycol (PEG) as a stabilizing agent. The effect of Cr doping on the structural, optical and magnetic properties of SnO{sub 2} nanoparticles was investigated. EDAX spectra confirmed the presence of Sn, O and Cr in near stoichiometry. XRD patterns revealed that particles of all samples were crystallized in single phase rutile type tetragonal crystal structure (P4{sub 2}/mnm) of SnO{sub 2}. The peak positions with Cr concentration shifted to higher 2θ values. Lattice parameters were also decreased with increasing Cr concentration. TEM studies indicated that the particle size is in the range of 8–10 nm. The optical absorption studies indicated that the absorption edge shifted towards lower wavelengths with inclusion of Cr content. FTIR spectrum displays various bands that are due to fundamental overtones of PEG and O–Sn–O entities. Further it revealed that the undoped and as well as Cr doped SnO{sub 2} nanoparticles were capped by PEG. Magnetization measurements at room temperature revealed that all the doped samples were ferromagnetic in nature. Well defined strong room temperature ferromagnetic hysteresis loop was observed for 1% Cr doped SnO{sub 2} nanoparticles.

  5. Quantitative, simultaneous, and collinear eye-tracked, high dynamic range optical coherence tomography at 850 and 1060 nm

    Science.gov (United States)

    Mooser, Matthias; Burri, Christian; Stoller, Markus; Luggen, David; Peyer, Michael; Arnold, Patrik; Meier, Christoph; Považay, Boris

    2017-07-01

    Ocular optical coherence tomography at the wavelengths ranges of 850 and 1060 nm have been integrated with a confocal scanning laser ophthalmoscope eye-tracker as a clinical commercial-class system. Collinear optics enables an exact overlap of the different channels to produce precisely overlapping depth-scans for evaluating the similarities and differences between the wavelengths to extract additional physiologic information. A reliable segmentation algorithm utilizing Graphcuts has been implemented and applied to automatically extract retinal and choroidal shape in cross-sections and volumes. The device has been tested in normals and pathologies including a cross-sectional and longitudinal study of myopia progress and control with a duplicate instrument in Asian children.

  6. Optics

    CERN Document Server

    Fincham, W H A

    2013-01-01

    Optics: Eighth Edition covers the work necessary for the specialization in such subjects as ophthalmic optics, optical instruments and lens design. The text includes topics such as the propagation and behavior of light; reflection and refraction - their laws and how different media affect them; lenses - thick and thin, cylindrical and subcylindrical; photometry; dispersion and color; interference; and polarization. Also included are topics such as diffraction and holography; the limitation of beams in optical systems and its effects; and lens systems. The book is recommended for engineering st

  7. Increased stability in laser metal wire deposition through feedback from optical measurements

    Science.gov (United States)

    Heralić, Almir; Christiansson, Anna-Karin; Ottosson, Mattias; Lennartson, Bengt

    2010-04-01

    Robotized laser metal-wire deposition is a fairly new technique being developed at University West in cooperation with Swedish industry for solid freeform fabrication of fully densed metal structures. It is developed around a standard welding cell and uses robotized fiber laser welding and wire filler material together with a layered manufacturing method to create metal structures. In this work a monitoring system, comprising two cameras and a projected laser line, is developed for on-line control of the deposition process. The controller is a combination of a PI-controller for the bead width and a feed-forward compensator for the bead height. It is evaluated through deposition of single-bead walls, and the results show that the process stability is improved when the proposed controller is used.

  8. SU-F-T-518: Development and Characterization of a Gated Treatment System Implemented with An In-House Optical Tracking System and the Elekta Response Interface

    International Nuclear Information System (INIS)

    Barraclough, B; Park, J; Li, F; Lu, B; Li, J; Liu, C; Yan, G

    2016-01-01

    Purpose: To report the development and characterization of the first in-house gating system implemented with an optical tracking system (OTS) and the Elekta Response™ interface. Methods: The Response™ connects a patient tracking system with a linac, enabling the tracking system to control radiation delivery. The developed system uses an in-house OTS to monitor patient breathing. The OTS consists of two infrared-based cameras, tracking markers affixed on patient. It achieves gated or breath-held (BH) treatment by calling beam ON/OFF functions in the Response™ dynamic-link library (DLL). A 4D motion phantom was used to evaluate its dosimetric and time delay characteristics. Two FF- and two FFF-IMRT beams were delivered in non-gated, BH and gated mode. The sinusoidal gating signal had a 6 sec period and 15 mm amplitude. The duty cycle included 10%, 20%, 30% and 50%. The BH signal was adapted from the sinusoidal wave by inserting 15 sec BHs. Each delivery was measured with a 2D diode array (MapCHECK™) and compared with the non-gated delivery using gamma analysis (3%). The beam ON/OFF time was captured using the service graphing utility of the linac. Results: The gated treatments were successfully delivered except the 10% duty cycle. The BH delivery had perfect agreement (100%) with non-gated delivery; the agreement of gated delivery decreased from 99% to 88% as duty cycle reduced from 50% to 20%. The beam on/off delay was on average 0.25/0.06 sec. The delivery time for the 50%, 30% and 20% duty cycle increased by 29%, 71% and 139%, respectively. No dosimetric or time delay difference was noticed between FF- and FFF-IMRT beams. Conclusion: The in-house gating system was successfully developed with dosimetric and time delay characteristics in line with published results for commercial systems. It will be an important platform for further research and clinical development of gated treatment.

  9. Slab track

    OpenAIRE

    Golob, Tina

    2014-01-01

    The last 160 years has been mostly used conventional track with ballasted bed, sleepers and steel rail. Ensuring the high speed rail traffic, increasing railway track capacities, providing comfortable and safe ride as well as high reliability and availability railway track, has led to development of innovative systems for railway track. The so-called slab track was first built in 1972 and since then, they have developed many different slab track systems around the world. Slab track was also b...

  10. Stability of the response and dependence of the optical signal as function of dose rate of the alanine gel dosimeter for electron clinic beams

    International Nuclear Information System (INIS)

    Silva, Cleber Feijo; Dias, Daniel Menezes; Campos, Leticia Lucente

    2009-01-01

    This work evaluates the stability of response and the dependence on the optical response of dose rate of the alanine gel solution developed at the IPEN, Sao Paulo, Brazil, for possible future usage as 3D dosemeter in the medical area, as the area is lack of measure instrumentation for three dimension dose

  11. Parameter design and experimental study of a bifunctional isolator for optical payload protection and stabilization

    Science.gov (United States)

    Wang, Guang-yuan; Guan, Xin; Cao, Dong-jing; Tang, Shao-fan; Chen, Xiang; Liang, Lu; Zheng, Gang-tie

    2017-11-01

    With the raise of resolution, optical payloads are becoming increasingly sensitive to satellite jitter. An approach where the entire spacecraft is pointed with great accuracy requires sophisticated and expensive bus design. In an effort to lower the overall cost of space missions that require highly stable line-of-sight pointing, a method of separating the bus and the payload with low frequency isolators is proposed. This isolation system can block the transmission of disturbance and allow relatively large bus motion. However, if the isolator is linear then there is a trade-off between isolation and static deflection as the launch and the on-orbit stage have difference requirements on the isolation frequency. Otherwise, an extra locking system should be appended to protect the payload before getting into orbit, as the STABLE isolation system[1] and the MIM isolation system[2] did. To overcome this limitation, an alternative approach is to design a nonlinear isolator with high-static stiffness during launch and low dynamic stiffness on orbit. Several specially designed nonlinear isolators have achieved low dynamic stiffness with large static load capacity. Virgin[3] considered a structure made from a highly deformed elastic element to achieve a softening spring. Platus[4] exploited the buckling of beams under axial load in a specific configuration to achieve a negative stiffness in combination with a positive stiffness, and hence low-dynamic stiffness. Others have achieved the same by connecting linear springs with positive stiffness in parallel with elements of negative stiffness[5] [7]. In the present study, a bifunctional isolator has been developed for optical payloads. The isolator have good performance both during launch and on orbit because of its specially designed nonlinear stiffness and damping. The isolator works in a linear part with low stiffness and small damping ratio under the micro-vibration and microgravity on orbit. The transmissibility

  12. A new method of surgical navigation for orthognathic surgery: optical tracking guided free-hand repositioning of the maxillomandibular complex.

    Science.gov (United States)

    Li, Biao; Zhang, Lei; Sun, Hao; Shen, Steve G F; Wang, Xudong

    2014-03-01

    In bimaxillary orthognathic surgery, the positioning of the maxilla and the mandible is typically accomplished via 2-splint technique, which may be the sources of several types of inaccuracy. To overcome the limitations of the 2-splint technique, we developed a new navigation method, which guided the surgeon to free-hand reposition the maxillomandibular complex as a whole intraoperatively, without the intermediate splint. In this preliminary study, the feasibility was demonstrated. Five patients with dental maxillofacial deformities were enrolled. Before the surgery, 3-dimensional planning was conducted and imported into a navigation system. During the operation, a tracker was connected to the osteotomized maxillomandibular complex via a splint. The navigation system tracked the movement of the complex and displayed it on the screen in real time to guide the surgeon to reposition the complex. The postoperative result was compared with the plan by analyzing the measured distances between the maxillary landmarks and reference planes, as determined from computed tomography data. The mean absolute errors of the maxillary position were clinically acceptable (<1.0 mm). Preoperative preparation time was reduced to 100 minutes on average. All patients were satisfied with the aesthetic results. This navigation method without intraoperative image registration provided a feasible means of transferring virtual planning to the real orthognathic surgery. The real-time position of the maxillomandibular complex was displayed on a monitor to visually guide the surgeon to reposition the complex. In this method, the traditional model surgery and the intermediate splint were discarded, and the preoperative preparation was simplified.

  13. Alpha-recoil tracks in natural dark mica: Dating geological samples by optical and scanning force microscopy

    International Nuclear Information System (INIS)

    Glasmacher, U.A.; Lang, M.; Klemme, S.; Moine, B.; Barbero, L.; Neumann, R.; Wagner, G.A.

    2003-01-01

    Alpha-recoil tracks (ART) are lattice defects caused by the α-decay of 238 U, 235 U, 232 Th, and daughter products. Visualization of etched ARTs in dark mica by phase-contrast microscopy allows dating of Quaternary geological as well as archaeological materials. Visualization of etched ARTs by Nomarski-differential-interference-contrast microscopy (NDICM) and scanning force microscopy (SFM) enables the access to areal densities (ρ a ) of ART etch pits beyond 10 4 mm -2 and thus the extension of the new ART-dating technique to an age range >1 Ma. The successful application of SFM as a new tool in geochronology could open the way to a field to be characterized as nanogeochronology. In order to visualize ARTs by NDICM and SFM, dark mica was etched with 4% HF at 21 deg. C for 5-107 min. A linear relationship between ρ a and etching time (t e ) was observed for phlogopites from the Kerguelen Islands (French territory, Indian Ocean), and the Kovdor magmatic complex (Russia). The volume density (ρ v ) of ART is a function of etching speed (v eff ) and slope of the ρ a -growth curve. The ART-age equation allows the calculation of an individual ρ v -growth curve for the phlogopite analysed by us using the uranium and thorium content. The ART-ages were determined by combining the experimentally obtained volume density with the individual ρ v -growth curve

  14. Note: Real time optical sensing of alpha-radiation emitting radioactive aerosols based on solid state nuclear track detector

    International Nuclear Information System (INIS)

    Kulkarni, A.; Bak, M. S.; Ha, S.; Joshirao, P.; Manchanda, V.; Kim, T.

    2015-01-01

    A sensitive radioactive aerosols sensor has been designed and developed. Its design guidance is based on the need for a low operational cost and reliable measurements to provide daily aerosol monitoring. The exposure of diethylene-glycol bis (allylcarbonate) to radiation causes modification of its physico-chemical properties like surface roughness and reflectance. In the present study, optical sensor based on the reflectance measurement has been developed with an aim to monitor real time presence of alpha radioactive aerosols emitted from thorium nitrate hydrate. The results shows that the fabricated sensor can detect 0.0157 kBq to 0.1572 kBq of radio activity by radioactive aerosols generated from (Th(NO 3 ) 4 ⋅ 5H 2 O) at 0.1 ml/min flow rate. The proposed instrument will be helpful to monitor radioactive aerosols in/around a nuclear facility, building construction sites, mines, and granite polishing factories

  15. Note: Real time optical sensing of alpha-radiation emitting radioactive aerosols based on solid state nuclear track detector

    Science.gov (United States)

    Kulkarni, A.; Ha, S.; Joshirao, P.; Manchanda, V.; Bak, M. S.; Kim, T.

    2015-06-01

    A sensitive radioactive aerosols sensor has been designed and developed. Its design guidance is based on the need for a low operational cost and reliable measurements to provide daily aerosol monitoring. The exposure of diethylene-glycol bis (allylcarbonate) to radiation causes modification of its physico-chemical properties like surface roughness and reflectance. In the present study, optical sensor based on the reflectance measurement has been developed with an aim to monitor real time presence of alpha radioactive aerosols emitted from thorium nitrate hydrate. The results shows that the fabricated sensor can detect 0.0157 kBq to 0.1572 kBq of radio activity by radioactive aerosols generated from (Th(NO3)4 ṡ 5H2O) at 0.1 ml/min flow rate. The proposed instrument will be helpful to monitor radioactive aerosols in/around a nuclear facility, building construction sites, mines, and granite polishing factories.

  16. Note: Real time optical sensing of alpha-radiation emitting radioactive aerosols based on solid state nuclear track detector

    Energy Technology Data Exchange (ETDEWEB)

    Kulkarni, A.; Bak, M. S., E-mail: tkim@skku.edu, E-mail: moonsoo@skku.edu [School of Mechanical Engineering, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Ha, S. [SKKU Advanced Institute of Nano Technology (SAINT), Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Joshirao, P.; Manchanda, V. [Department of Energy Science, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Kim, T., E-mail: tkim@skku.edu, E-mail: moonsoo@skku.edu [School of Mechanical Engineering, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); SKKU Advanced Institute of Nano Technology (SAINT), Sungkyunkwan University, Suwon 440-746 (Korea, Republic of)

    2015-06-15

    A sensitive radioactive aerosols sensor has been designed and developed. Its design guidance is based on the need for a low operational cost and reliable measurements to provide daily aerosol monitoring. The exposure of diethylene-glycol bis (allylcarbonate) to radiation causes modification of its physico-chemical properties like surface roughness and reflectance. In the present study, optical sensor based on the reflectance measurement has been developed with an aim to monitor real time presence of alpha radioactive aerosols emitted from thorium nitrate hydrate. The results shows that the fabricated sensor can detect 0.0157 kBq to 0.1572 kBq of radio activity by radioactive aerosols generated from (Th(NO{sub 3}){sub 4} ⋅ 5H{sub 2}O) at 0.1 ml/min flow rate. The proposed instrument will be helpful to monitor radioactive aerosols in/around a nuclear facility, building construction sites, mines, and granite polishing factories.

  17. Thermal, optical and dielectric properties of phase stabilized δ - Dy-Bi2O3 ionic conductors

    Science.gov (United States)

    Bandyopadhyay, Swagata; Dutta, Abhigyan

    2017-03-01

    In this work, we have investigated the thermal, structural, optical and dielectric properties of Bi1-xDyxO1.5-δ (0.10≤x≤0.40) ionic conductors prepared by citrate auto-ignition method. The Thermo gravimetric-DTA analysis and X-Ray Diffraction pattern confirm the single δ-phase stabilization of doped system beyond 25 mol% doping concentration. XRD analysis also indicates that average crystallite size is maximum and micro strain is minimum for Bi0.75Dy0.25O1.5-δ composition. The optical band gap of the prepared compositions is obtained from the Ultraviolet- Visible spectroscopy that shows a red shift with the increase in Dy content. The presence of different structural bonds is confirmed from FT-IR spectroscopy analysis. Ionic transport property of the prepared compositions has been analyzed using Nyquist plot for dc conduction and Nernst-Einstein relation for ac conduction mechanism. This analysis indicates that the composition Bi0.75Dy0.25O1.5-δ shows highest conductivity. The dielectric properties of these ionic conductors have been analyzed using Havriliak-Negami (HN) formalism. The dielectric permittivity ε' (ω) of all the prepared compositions is found to be within the range 1.61-3.63(x102) in S.I. unit. Analysis of electric modulus data reveals that dielectric and modulus relaxation follows same mechanism. The time-temperature superposition principle has been verified from the scaling of modulus spectra.

  18. Optical studies of the solution phase reduction and stabilization of indigo tetrasulfonate in polyelectrolyte complexes.

    Science.gov (United States)

    Hoene, Becca; Rivera, Dion

    2017-09-01

    Ultraviolet-visible (UV-vis) and fluorescence spectroscopy have been used to characterize the polyelectrolyte complexes (PECs) formed when potassium indigo tetrasulfonate (ITS) interacts with poly diallydimethylammonium chloride (PDADMAC) through columbic attraction in the presence of the reducing agent sodium bisulfite, NaHSO 3 . The PDADMAC facilitates both the reduction of the ITS and the stabilization of the reduced state of the ITS in an atmospheric oxygen environment. Dilutions of the dye solution show that the PEC is stable to dilutions of at least 1 to 1000. UV-vis studies indicate that the reduced ITS (ITS red ) forms what is likely a J-aggregate in the presence of PDADMAC with an absorbance band red shifted from the normal absorbance band of reduced ITS by roughly 130 nm, 390 nm to 520 nm. Excitation of the PEC solution at either 390 nm or 520 nm produces an emission spectrum of the aggregated complex with an emission maximum near 534 nm. Monomer emission at 480 nm of ITS red represents only 3.0 ± 0.5% of the emission signal of the aggregated complex. Kinetic studies using fluorescence spectroscopy over a temperature range of 30 to 70 °C and dilutions of dye solutions ranging from 1:10 to 1:1000 yield data for the oxidation of ITS red that is best fit by a first order rate constant. Kinetic data displays two distinctive regimes, a short time rate and a long time rate. These two distinct kinetic regimes are likely due to the reduced ITS interacting with an outer PEC environment and an inner PEC environment. First order rate constants could be used to estimate Δ ‡ H and Δ ‡ S of the oxidation reaction. Fluorescence data was used to calculate the partitioning of reduced ITS molecules between the outer and inner PEC environments. Partitioning from the inner to outer PEC environment was found to be entropically driven. Addition of NaCl to the diluted dye solutions could alter the kinetics of the oxidation but the significance of the effect depended on

  19. Optical studies of the solution phase reduction and stabilization of indigo tetrasulfonate in polyelectrolyte complexes

    Directory of Open Access Journals (Sweden)

    Becca Hoene

    2017-09-01

    Full Text Available Ultraviolet-visible (UV-vis and fluorescence spectroscopy have been used to characterize the polyelectrolyte complexes (PECs formed when potassium indigo tetrasulfonate (ITS interacts with poly diallydimethylammonium chloride (PDADMAC through columbic attraction in the presence of the reducing agent sodium bisulfite, NaHSO3. The PDADMAC facilitates both the reduction of the ITS and the stabilization of the reduced state of the ITS in an atmospheric oxygen environment. Dilutions of the dye solution show that the PEC is stable to dilutions of at least 1 to 1000. UV–vis studies indicate that the reduced ITS (ITSred forms what is likely a J-aggregate in the presence of PDADMAC with an absorbance band red shifted from the normal absorbance band of reduced ITS by roughly 130 nm, 390 nm to 520 nm. Excitation of the PEC solution at either 390 nm or 520 nm produces an emission spectrum of the aggregated complex with an emission maximum near 534 nm. Monomer emission at 480 nm of ITSred represents only 3.0 ± 0.5% of the emission signal of the aggregated complex. Kinetic studies using fluorescence spectroscopy over a temperature range of 30 to 70 °C and dilutions of dye solutions ranging from 1:10 to 1:1000 yield data for the oxidation of ITSred that is best fit by a first order rate constant. Kinetic data displays two distinctive regimes, a short time rate and a long time rate. These two distinct kinetic regimes are likely due to the reduced ITS interacting with an outer PEC environment and an inner PEC environment. First order rate constants could be used to estimate Δ‡H and Δ‡S of the oxidation reaction. Fluorescence data was used to calculate the partitioning of reduced ITS molecules between the outer and inner PEC environments. Partitioning from the inner to outer PEC environment was found to be entropically driven. Addition of NaCl to the diluted dye solutions could alter the kinetics of the oxidation but the significance of the effect

  20. Micro-electro-mechanical system (MEMS)-based fiber optic sensor and sensor network for improving weapon stabilization and fire control

    Science.gov (United States)

    Zhang, Sean Z.; Xu, Guoda; Qiu, Wei; Lin, Freddie S.; Testa, Robert C.; Mattice, Michael S.

    2000-08-01

    A MicroElectroMechanical Systems (MEMS)-based fiber optic sensor and sensor network for improving weapon stabilization and fire control have been developed. Fabrication involves overwriting two fiber Bragg gratings (FBGs) onto a polarization-preserving optical fiber core. A MEMS diaphragm is fabricated and integrated with the overlaid FBGs to enhance the performance and reliability of the sensor. A simulation model for the MEMS fiber optic sensor and sensor network has been derived, and simulation results concerning load, angle, strain, and temperature have been obtained. The fabricated MEMS diaphragm and the overlaid FBGs have been packaged together on the basis of simulation results and mounted on a specially designed cantilever system. The combined multifunctional MEMS fiber optic sensor and sensor network is cost-effective, fast, rugged enough to operate in harsh environmental conditions, compact, and highly sensitive.

  1. Preparation, optical properties, magnetic properties and thermal stability of core-shell structure cobalt/zinc oxide nanocomposites

    International Nuclear Information System (INIS)

    Bala, Hari; Fu Wuyou; Yu Yanhui; Yang Haibin; Zhang Yishun

    2009-01-01

    Cobalt nanoparticles coated with zinc oxide can form composite spheres with core-shell structure. This coating process was based on the use of silane coupling with agent 3-mercaptopropyltrimethoxysilane (HS-(CH 2 ) 3 Si(OCH 3 ) 3 , MPTS) as a primer to render the cobalt surface vitreophilic, thus it renders cobalt surface compatible with ZnO. X-ray photoelectron spectroscopy (XPS) was used to gain insight into the way in which the MPTS is bound to the surface of the cobalt nanoparticles. The morphological structure, chemical composition, optical properties and magnetic properties of the product were investigated by using transmission electron microscopy (TEM), X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDS), photoluminescence (PL) spectroscope and vibrating sample magnetometer (VSM). It was found that the Co/ZnO core-shell structure nanocomposites exhibited both of favorable magnetism and photoluminescence properties. Results of the thermogravimetric analysis (TGA) and differential thermal analysis (DTA) indicated that the thermal stability of cobalt/zinc oxide was better than that of pure cobalt nanoparticles.

  2. Preparation, optical properties, magnetic properties and thermal stability of core-shell structure cobalt/zinc oxide nanocomposites

    Science.gov (United States)

    Bala, Hari; Fu, Wuyou; Yu, Yanhui; Yang, Haibin; Zhang, Yishun

    2009-01-01

    Cobalt nanoparticles coated with zinc oxide can form composite spheres with core-shell structure. This coating process was based on the use of silane coupling with agent 3-mercaptopropyltrimethoxysilane (HS-(CH 2) 3Si(OCH 3) 3, MPTS) as a primer to render the cobalt surface vitreophilic, thus it renders cobalt surface compatible with ZnO. X-ray photoelectron spectroscopy (XPS) was used to gain insight into the way in which the MPTS is bound to the surface of the cobalt nanoparticles. The morphological structure, chemical composition, optical properties and magnetic properties of the product were investigated by using transmission electron microscopy (TEM), X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDS), photoluminescence (PL) spectroscope and vibrating sample magnetometer (VSM). It was found that the Co/ZnO core-shell structure nanocomposites exhibited both of favorable magnetism and photoluminescence properties. Results of the thermogravimetric analysis (TGA) and differential thermal analysis (DTA) indicated that the thermal stability of cobalt/zinc oxide was better than that of pure cobalt nanoparticles.

  3. Preparation, optical properties, magnetic properties and thermal stability of core-shell structure cobalt/zinc oxide nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Bala, Hari [Institute of Materials Science and Engineering, Henan Polytechnic University, Jiaozuo 454000 (China); State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China)], E-mail: hari@hpu.edu.cn; Fu Wuyou [National Laboratory for Superhard Materials, JiIin University, Changchun 130023 (China); Yu Yanhui [Institute of Materials Science and Engineering, Henan Polytechnic University, Jiaozuo 454000 (China); Yang Haibin [Institute of Materials Science and Engineering, Henan Polytechnic University, Jiaozuo 454000 (China); National Laboratory for Superhard Materials, JiIin University, Changchun 130023 (China); Zhang Yishun [Institute of Materials Science and Engineering, Henan Polytechnic University, Jiaozuo 454000 (China)

    2009-01-15

    Cobalt nanoparticles coated with zinc oxide can form composite spheres with core-shell structure. This coating process was based on the use of silane coupling with agent 3-mercaptopropyltrimethoxysilane (HS-(CH{sub 2}){sub 3}Si(OCH{sub 3}){sub 3}, MPTS) as a primer to render the cobalt surface vitreophilic, thus it renders cobalt surface compatible with ZnO. X-ray photoelectron spectroscopy (XPS) was used to gain insight into the way in which the MPTS is bound to the surface of the cobalt nanoparticles. The morphological structure, chemical composition, optical properties and magnetic properties of the product were investigated by using transmission electron microscopy (TEM), X-ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDS), photoluminescence (PL) spectroscope and vibrating sample magnetometer (VSM). It was found that the Co/ZnO core-shell structure nanocomposites exhibited both of favorable magnetism and photoluminescence properties. Results of the thermogravimetric analysis (TGA) and differential thermal analysis (DTA) indicated that the thermal stability of cobalt/zinc oxide was better than that of pure cobalt nanoparticles.

  4. Noninvasive in vivo optical coherence tomography tracking of chronic otitis media in pediatric subjects after surgical intervention

    Science.gov (United States)

    Monroy, Guillermo L.; Pande, Paritosh; Nolan, Ryan M.; Shelton, Ryan L.; Porter, Ryan G.; Novak, Michael A.; Spillman, Darold R.; Chaney, Eric J.; McCormick, Daniel T.; Boppart, Stephen A.

    2017-12-01

    In an institutional review board-approved study, 25 pediatric subjects diagnosed with chronic or recurrent otitis media were observed over a period of six months with optical coherence tomography (OCT). Subjects were followed throughout their treatment at the initial patient evaluation and preoperative consultation, surgery (intraoperative imaging), and postoperative follow-up, followed by an additional six months of records-based observation. At each time point, the tympanic membrane (at the light reflex region) and directly adjacent middle-ear cavity were observed in vivo with a handheld OCT probe and portable system. Imaging results were compared with clinical outcomes to correlate the clearance of symptoms in relation to changes in the image-based features of infection. OCT images of most all participants showed the presence of additional infection-related biofilm structures during their initial consultation visit and similarly for subjects imaged intraoperatively before myringotomy. Subjects with successful treatment (no recurrence of infectious symptoms) had no additional structures visible in OCT images during the postoperative visit. OCT image findings suggest surgical intervention consisting of myringotomy and tympanostomy tube placement provides a means to clear the middle ear of infection-related components, including middle-ear fluid and biofilms. Furthermore, OCT was demonstrated as a rapid diagnostic tool to prospectively monitor patients in both outpatient and surgical settings.

  5. Self-excited multi-scale skin vibrations probed by optical tracking micro-motions of tracers on arms

    Science.gov (United States)

    Chen, Wei-Chia; Chen, Hsiang-Ying; Chen, Yu-Sheng; Tian, Yong; I, Lin

    2017-07-01

    The self-excited multi-scale mechanical vibrations, their sources and their mutual coupling of different regions on the forearms of supine subjects, are experimentally investigated, using a simple noncontact method, optical video microscopy, which provides 1 μm and 25 ms spatiotemporal resolutions. It is found that, in proximal regions far from the radial artery, the vibrations are the global vibrations of the entire forearm excited by remote sources, propagating through the trunk and the limb. The spectrum is mainly composed of peaks of very low frequency motion (down to 0.05 Hz), low frequency respiration modes, and heartbeat induced modes (about 1 Hz and its harmonics), standing out of the spectrum floor exhibiting power law decay. The nonlinear mode-mode coupling leads to the cascaded modulations of higher frequency modes by lower frequency modes. The nearly identical waveforms without detectable phase delays for a pair of signals along or transverse to the meridian of regions far away from the artery rule out the detectable contribution from the propagation of Qi, some kind of collective excitation which more efficiently propagates along meridians, according to the Chinese medicine theory. Around the radial artery, in addition to the global vibration, the local vibration spectrum shows very slow breathing type vibration around 0.05 Hz, and the artery pulsation induced fundamental and higher harmonics with descending intensities up to the fifth harmonics, standing out of a flat spectrum floor. All the artery pulsation modes are also modulated by respiration and the very slow vibration.

  6. Real-time chest-wall-motion tracking by a single optical fibre grating: a prospective method for ventilator triggering.

    Science.gov (United States)

    Ivanovic, Marija D; Petrovic, Jovana; Savic, Andrej; Gligoric, Goran; Miletic, Marjan; Vukcevic, Miodrag; Bojovic, Bosko; Hadzievski, Ljupco; Allsop, Tom D P; Webb, David J

    2018-03-19

    The ventilators involved in non-invasive mechanical ventilation commonly provide ventilator support via a facemask. The interface of the mask with a patient promotes air leaks that cause errors in the feedback information provided by a pneumatic sensor and hence patient-ventilator asynchrony with multiple negative consequences. Our objective is to test the possibility of using chest-wall motion measured by an optical fibre-grating sensor as a more accurate non-invasive ventilator triggering mechanism. Approach: The basic premise of our approach is that the measurement accuracy can be improved by using a triggering signal that precedes pneumatic triggering in the neuro-ventilatory coupling sequence. We propose a technique that uses the measurement of chest-wall curvature by a long-period fibre-grating sensor. The sensor was applied externally to the rib-cage and interrogated in the lateral (edge) filtering scheme. The study was performed on 34 healthy volunteers. Statistical data analysis of the time lag between the fibre-grating sensor and the reference pneumotachograph was preceded by the removal of the unwanted heartbeat signal by wavelet transform processing. Main results: The results show a consistent fibre-grating signal advance with respect to the standard pneumatic signal by (230±100) ms in both the inspiratory and expiratory phases. We further show that heart activity removal yields a tremendous improvement in sensor accuracy by reducing it from 60 ml to 0.3 ml. Significance: The results indicate that the proposed measurement technique may lead to a more reliable triggering decision. Its imperviousness to air leaks, non-invasiveness, low-cost and ease of implementation offer good prospects for applications in both clinical and homecare ventilation. . © 2018 Institute of Physics and Engineering in Medicine.

  7. Impact of revascularization of coronary chronic total occlusion on left ventricular function and electrical stability: analysis by speckle tracking echocardiography and signal-averaged electrocardiogram.

    Science.gov (United States)

    Sotomi, Yohei; Okamura, Atsunori; Iwakura, Katsuomi; Date, Motoo; Nagai, Hiroyuki; Yamasaki, Tomohiro; Koyama, Yasushi; Inoue, Koichi; Sakata, Yasushi; Fujii, Kenshi

    2017-06-01

    The present study aimed to assess the mechanisms of effects of percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) from two different aspects: left ventricular (LV) systolic function assessed by two-dimensional speckle tracking echocardiography (2D-STE) and electrical stability evaluated by late potential on signal-averaged electrocardiogram (SAECG). We conducted a prospective observational study with consecutive CTO-PCI patients. 2D-STE and SAECG were performed before PCI, and after 1-day and 3-months of procedure. 2D-STE computed global longitudinal strain (GLS) and regional longitudinal strain (RLS) in CTO area, collateral blood-supplying donor artery area, and non-CTO/non-donor area. A total of 37 patients (66 ± 11 years, 78% male) were analyzed. RLS in CTO and donor areas and GLS were significantly improved 1-day after the procedure, but these improvements diminished during 3 months. The improvement of RLS in donor area remained significant after 3-months the index procedure (pre-PCI -13.4 ± 4.8% vs. post-3M -15.1 ± 4.5%, P = 0.034). RLS in non-CTO/non-donor area and LV ejection fraction were not influenced. Mitral annulus velocity was improved at 3-month follow-up (5.0 ± 1.4 vs. 5.6 ± 1.7 cm/s, P = 0.049). Before the procedure, 12 patients (35%) had a late potential. All components of the late potential (filtered QRS duration, root-mean-square voltage in the terminal 40 ms, and duration of the low amplitude signal <40 μV) were not improved. CTO-PCI improved RLS in the donor area at 3-month follow-up without changes of LV ejection fraction. Although higher prevalence of late potential in the current population compared to healthy population was observed, late potential as a surrogate of arrhythmogenic substrate was not influenced by CTO-PCI.

  8. Acquisition, tracking, and pointing III; Proceedings of the Meeting, Orlando, FL, Mar. 27-29, 1989

    Science.gov (United States)

    Gowrinathan, Sankaran

    1989-09-01

    The present conference on components and sensors, image processing algorithms, and astronomical applications for pointing and tracking gives attention to a CCD daylight stellar sensor, an optical coordinate transfer assembly for precision boresight applications, a grating carousel mechanism for the HST high resolution spectrograph, an IR antiship-seeker simulator, line-of-sight stabilization using image motion compensation, the effects of illumination beam jitter on photodetection statistics, and the enhancement of armored vehicle fire control performance. Also discussed are active angular tracking with a photon-bucket, moving target estimation with autodyne detection, multiresolution object detection and segmentation, a beacon tracker and point-ahead system for optical communications, a precision-pointing mechanism for intersatellite optical communication, high-precision lunar tracking for laser ranging, multimirror beam control, and fundamental limits in the resolution of double-star targets.

  9. High Dynamics and Precision Optical Measurement Using a Position Sensitive Detector (PSD in Reflection-Mode: Application to 2D Object Tracking over a Smart Surface

    Directory of Open Access Journals (Sweden)

    Ioan Alexandru Ivan

    2012-12-01

    Full Text Available When related to a single and good contrast object or a laser spot, position sensing, or sensitive, detectors (PSDs have a series of advantages over the classical camera sensors, including a good positioning accuracy for a fast response time and very simple signal conditioning circuits. To test the performance of this kind of sensor for microrobotics, we have made a comparative analysis between a precise but slow video camera and a custom-made fast PSD system applied to the tracking of a diffuse-reflectivity object transported by a pneumatic microconveyor called Smart-Surface. Until now, the fast system dynamics prevented the full control of the smart surface by visual servoing, unless using a very expensive high frame rate camera. We have built and tested a custom and low cost PSD-based embedded circuit, optically connected with a camera to a single objective by means of a beam splitter. A stroboscopic light source enhanced the resolution. The obtained results showed a good linearity and a fast (over 500 frames per second response time which will enable future closed-loop control by using PSD.

  10. Digital Image-Based Automatic Tracking Capability, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — OPTRA proposes to develop an Automated Optical Tracking Capability tailored to NASA's network of optical tracking stations at the Kennedy Space Center. This will be...

  11. A highly efficient silole-containing dithienylethene with excellent thermal stability and fatigue resistance: a promising candidate for optical memory storage materials.

    Science.gov (United States)

    Chan, Jacky Chi-Hung; Lam, Wai Han; Yam, Vivian Wing-Wah

    2014-12-10

    Diarylethene compounds are potential candidates for applications in optical memory storage systems and photoswitchable molecular devices; however, they usually show low photocycloreversion quantum yields, which result in ineffective erasure processes. Here, we present the first highly efficient photochromic silole-containing dithienylethene with excellent thermal stability and fatigue resistance. The photochemical quantum yields for photocyclization and photocycloreversion of the compound are found to be high and comparable to each other; the latter of which is rarely found in diarylethene compounds. These would give rise to highly efficient photoswitchable material with effective writing and erasure processes. Incorporation of the silole moiety as a photochromic dithienylethene backbone also was demonstrated to enhance the thermal stability of the closed form, in which the thermal backward reaction to the open form was found to be negligible even at 100 °C, which leads to a promising candidate for use as photoswitchable materials and optical memory storage.

  12. Evaluation of the stability of Boston type I keratoprosthesis-donor cornea interface using anterior segment optical coherence tomography.

    Science.gov (United States)

    Garcia, Julian P S; Ritterband, David C; Buxton, Douglas F; De la Cruz, Jose

    2010-09-01

    To evaluate the anatomic stability of an implanted Boston type I keratoprosthesis (KPro)-donor cornea interface and assess the presence or absence of a potential space (gap) between the KPro front plate and donor cornea using anterior segment optical coherence tomography (AS-OCT). The presence of a gap would raise concerns of a possible pathway for the exchange of extraocular fluid with the anterior chamber. Fifteen eyes implanted with a Boston type I KPro were studied by the noncontact technique of AS-OCT (AC Cornea OCT prototype; OTI, Canada). All the KPro devices had been implanted at least 4 weeks before the study (mean: 7 months, range: 1-22 months). Eight eyes had aphakic Kpros, and the other 7 had pseudophakic implants. Anesthetized eyes were imaged before and during pressure application using sterile cotton-tip applicators. Pressure was applied for 10 seconds on the nasal or temporal side of the eye. Images were analyzed for any possible changes in the KPro-donor cornea interface during the application of pressure. Of 15 eyes, 10 had the threaded front plate model with a T-shaped silhouette and corrugated sides, whereas 5 had the threadless type with a T-shaped silhouette and smooth sides on cross-sectional optical coherence tomography. Of the 15 eyes, 2 revealed a gap between the front plate and the surface of the donor cornea. The rest revealed no gaps. With pressure, none of the eyes, including the 2 with gaps, demonstrated any change in the KPro-donor cornea interface during dynamic imaging (eg, gaping or evidence of fluid escape along the KPro-donor cornea borders). In all eyes, the position of the titanium locking ring was visible and verified to be in an adequate position. The implanted KPro-donor cornea interface seems to be stable dynamically using AS-OCT. A gap that has been documented with this imaging tool showed neither gaping nor escape of anterior chamber fluid during dynamic cross-sectional imaging. Further studies will be needed to assess

  13. Effect of cobalt doping on crystallinity, stability, magnetic and optical properties of magnetic iron oxide nano-particles

    Energy Technology Data Exchange (ETDEWEB)

    Anjum, Safia, E-mail: safia_anjum@hotmail.com [Department of Physics, Lahore College for Women University, Lahore (Pakistan); Tufail, Rabia [Department of Physics, Lahore College for Women University, Lahore (Pakistan); Rashid, Khalid [PCSIR Laboratories Lahore (Pakistan); Zia, Rehana [Department of Physics, Lahore College for Women University, Lahore (Pakistan); Riaz, S. [Centre for Solid State Physics, University of the Punjab, Lahore (Pakistan)

    2017-06-15

    Highlights: • The stability of Co{sub x}Fe{sub (2-x)}O{sub 3} nanoparticles enhances. • Energy losses increases. • Anisotropy of NP is high. - Abstract: This paper is dedicated to investigate the effect of Co{sup 2+} ions in magnetite Fe{sub 3}O{sub 4} nano-particles with stoichiometric formula Co{sub x}Fe{sub 3-x}O{sub 4} where (x = 0, 0.05, 0.1 and 0.15) prepared by co-precipitation method. The structural, thermal, morphological, magnetic and optical properties of magnetite and Co{sup 2+} doped magnetite nanoparticles have been carried out using X-ray Diffractometer, Fourier Transform Infrared Spectroscopy, Themogravimetric Analysis, Scanning Electron Microscopy, Vibrating Sample Magnetometer (VSM) and UV–Vis Spectrometer (UV–Vis) respectively. Structural analysis verified the formation of single phase inverse spinel cubic structure with decrease in lattice parameters due to increase in cobalt content. FTIR analysis confirms the single phase of Co{sub x}Fe{sub 3-x}O{sub 4} nanoparticles with the major band at 887 cm{sup −1}, which might be due to the stretching vibrations of metal-oxide bond. The DSC results corroborate the finding of an increase in the maghemite to hematite phase transition temperature with increase in Co{sup 2+} content. The decrease in enthalpy with increase in Co{sup 2+} concentration attributed to the fact that the degree of conversion from maghemite to hematite decrease which shows that the stability increases with increasing Co{sup 2+} content in B-site of Fe{sub 3}O{sub 4} structure. SEM analysis demonstrated the formation of spherical shaped nanoparticles with least agglomeration. The magnetic measurements enlighten that the coercivity and anisotropy of Co{sub x}Fe{sub 3-x}O{sub 4} nanoparticles are significantly increased. From UV–Vis analysis it is revealed that band gap energy increases with decreasing particle size. This result has a great interest for magnetic fluid hyperthermia application (MPH).

  14. Effect of cobalt doping on crystallinity, stability, magnetic and optical properties of magnetic iron oxide nano-particles

    Science.gov (United States)

    Anjum, Safia; Tufail, Rabia; Rashid, Khalid; Zia, Rehana; Riaz, S.

    2017-06-01

    This paper is dedicated to investigate the effect of Co2+ ions in magnetite Fe3O4 nano-particles with stoichiometric formula CoxFe3-xO4 where (x = 0, 0.05, 0.1 and 0.15) prepared by co-precipitation method. The structural, thermal, morphological, magnetic and optical properties of magnetite and Co2+ doped magnetite nanoparticles have been carried out using X-ray Diffractometer, Fourier Transform Infrared Spectroscopy, Themogravimetric Analysis, Scanning Electron Microscopy, Vibrating Sample Magnetometer (VSM) and UV-Vis Spectrometer (UV-Vis) respectively. Structural analysis verified the formation of single phase inverse spinel cubic structure with decrease in lattice parameters due to increase in cobalt content. FTIR analysis confirms the single phase of CoxFe3-xO4 nanoparticles with the major band at 887 cm-1, which might be due to the stretching vibrations of metal-oxide bond. The DSC results corroborate the finding of an increase in the maghemite to hematite phase transition temperature with increase in Co2+ content. The decrease in enthalpy with increase in Co2+ concentration attributed to the fact that the degree of conversion from maghemite to hematite decrease which shows that the stability increases with increasing Co2+ content in B-site of Fe3O4 structure. SEM analysis demonstrated the formation of spherical shaped nanoparticles with least agglomeration. The magnetic measurements enlighten that the coercivity and anisotropy of CoxFe3-xO4 nanoparticles are significantly increased. From UV-Vis analysis it is revealed that band gap energy increases with decreasing particle size. This result has a great interest for magnetic fluid hyperthermia application (MPH).

  15. Structure, thermal, optical and electrical investigation of the effect of heavy highly energetic ions irradiations in Bayfol DPF 5023 nuclear track detector

    International Nuclear Information System (INIS)

    Nouh, S.A.; Radwan, Y.E.; Elfiky, D.; Abutalib, M.M.; Bahareth, R.A.; Hegazy, T.M.; Fouad, S.S.

    2014-01-01

    The effects of 28 GeV 56 Fe ion irradiation on the structural, thermal, optical and electrical properties of Bayfol DPF 5023 have been investigated. Samples from Bayfol sheets have been irradiated using different Fe fluences in the range 1×10 12 to 5×10 15 ion/cm 2 . The total energy deposited is between (28×10 21 eV and 14×10 25 eV). The resultant effect of Fe ion irradiation on the properties of Bayfol has been investigated using FTIR spectroscopy, intrinsic viscosity, Thermogravimetric Analysis TGA, refractive index, color changes, and DC conductivity. The results indicate that the Fe ion irradiation in the fluence range 10 12 –10 15 ion/cm 2 led to a more compact structure of Bayfol polymer, which resulted in an improvement in its thermal stability with an increase in activation energy of thermal decomposition and crosslinking. This crosslinking enhanced the intrinsic viscosity of Bayfol from 0.58 to 0.89 at 35 °C, indicating an increase in the average molecular mass. This was accompanied with an increase in refractive index. Further, the transmission of Bayfol samples in the wavelength range of 370–780 nm, as well as any color changes, was studied. The color intensity ΔE was increased with increasing the Fe fluence, and was accompanied by a significant increase in the blue color component. - Highlights: • Fe ion irradiation led to a more compact structure of Bayfol with enhanced thermal stability. • Both average molecular mass and isotropic nature of Bayfol increased with irradiation. • The Bayfol samples showed significant color sensitivity toward Fe ion irradiation. • Fe ion irradiation provides mobile-free charge carriers that increase DC conductivity

  16. INNER TRACKING

    CERN Multimedia

    P. Sharp

    The CMS Inner Tracking Detector continues to make good progress. The successful commissioning of ~ 25% of the Silicon Strip Tracker was completed in the Tracker Integration Facility (TIF) at CERN on 18 July 2007 and the Tracker has since been prepared for moving and installation into CMS at P5. The Tracker will be ready to move on schedule in September 2007. The Installation of the Tracker cooling pipes and LV cables between Patch Panel 1 (PP1) on the inside the CMS magnet cryostat, and the cooling plants and power system racks on the balconies has been completed. The optical fibres from PP1 to the readout FEDs in the USC will be installed in parallel with the installation of the EB/HB services, and will be completed in October. It is planned to install the Tracker into CMS at the end of October, after the completion of the installation of the EB/HB services. The Tracker will then be connected to the pre-installed services on YB0 and commissioned with CMS in December. The FPix and BPix continue to make ...

  17. INNER TRACKING

    CERN Multimedia

    P. Sharp

    The CMS Inner Tracking Detector continues to make good progress. The successful commissioning of ~ 25% of the Silicon Strip Tracker was completed in the Tracker Integration Facility (TIF) at CERN in July 2007 and the Tracker has since been prepared for moving and installation into CMS at P5. The Tracker was ready to move on schedule in September 2007. The Installation of the Tracker cooling pipes and LV cables between Patch Panel 1 (PP1) on the inside the CMS magnet cryostat, and the cooling plants and power system racks on the balconies has been completed. The optical fibres from PP1 to the readout FEDs in the USC have been installed, together with the Tracker cable channels, in parallel with the installation of the EB/HB services. All of the Tracker Safety, Power, DCS and the VME Readout Systems have been installed at P5 and are being tested and commissioned with CMS. It is planned to install the Tracker into CMS before Christmas. The Tracker will then be connected to the pre-installed services on Y...

  18. Fundamental transverse mode selection and self-stabilization in large optical cavity diode lasers under high injection current densities

    Science.gov (United States)

    Avrutin, Eugene A.; Ryvkin, Boris S.; Payusov, Alexey S.; Serin, Artem A.; Gordeev, Nikita Yu

    2015-11-01

    It is shown that in high-power, large optical cavity laser diodes at high injection currents, the optical losses due to nonuniform carrier accumulation in the optical confinement layer can ensure the laser operation in the fundamental transverse mode. An experimental demonstration of switching from second order mode to fundamental mode in large optical cavity lasers with current and/or temperature increase is reported and explained, with the calculated values for the switching current and temperature in good agreement with the measurements. The results experimentally prove the nonuniform nature of carrier accumulation in the confinement layer and may aid laser design for optimizing the output.

  19. Persistent Aerial Tracking

    KAUST Repository

    Mueller, Matthias

    2016-04-13

    In this thesis, we propose a new aerial video dataset and benchmark for low altitude UAV target tracking, as well as, a photo-realistic UAV simulator that can be coupled with tracking methods. Our benchmark provides the rst evaluation of many state of-the-art and popular trackers on 123 new and fully annotated HD video sequences captured from a low-altitude aerial perspective. Among the compared trackers, we determine which ones are the most suitable for UAV tracking both in terms of tracking accuracy and run-time. We also present a simulator that can be used to evaluate tracking algorithms in real-time scenarios before they are deployed on a UAV "in the field", as well as, generate synthetic but photo-realistic tracking datasets with free ground truth annotations to easily extend existing real-world datasets. Both the benchmark and simulator will be made publicly available to the vision community to further research in the area of object tracking from UAVs. Additionally, we propose a persistent, robust and autonomous object tracking system for unmanned aerial vehicles (UAVs) called Persistent Aerial Tracking (PAT). A computer vision and control strategy is applied to a diverse set of moving objects (e.g. humans, animals, cars, boats, etc.) integrating multiple UAVs with a stabilized RGB camera. A novel strategy is employed to successfully track objects over a long period, by \\'handing over the camera\\' from one UAV to another. We integrate the complete system into an off-the-shelf UAV, and obtain promising results showing the robustness of our solution in real-world aerial scenarios.

  20. Tracking frequency laser distance gauge

    International Nuclear Information System (INIS)

    Phillips, J.D.; Reasenberg, R.D.

    2005-01-01

    Advanced astronomical missions with greatly enhanced resolution and physics missions of unprecedented accuracy will require laser distance gauges of substantially improved performance. We describe a laser gauge, based on Pound-Drever-Hall locking, in which the optical frequency is adjusted to maintain an interferometer's null condition. This technique has been demonstrated with pm performance. Automatic fringe hopping allows it to track arbitrary distance changes. The instrument is intrinsically free of the nm-scale cyclic bias present in traditional (heterodyne) high-precision laser gauges. The output is a radio frequency, readily measured to sufficient accuracy. The laser gauge has operated in a resonant cavity, which improves precision, can suppress the effects of misalignments, and makes possible precise automatic alignment. The measurement of absolute distance requires little or no additional hardware, and has also been demonstrated. The proof-of-concept version, based on a stabilized HeNe laser and operating on a 0.5 m path, has achieved 10 pm precision with 0.1 s integration time, and 0.1 mm absolute distance accuracy. This version has also followed substantial distance changes as fast as 16 mm/s. We show that, if the precision in optical frequency is a fixed fraction of the linewidth, both incremental and absolute distance precision are independent of the distance measured. We discuss systematic error sources, and present plans for a new version of the gauge based on semiconductor lasers and fiber-coupled components

  1. Particle tracking

    CERN Document Server

    Safarík, K; Newby, J; Sørensen, P

    2002-01-01

    In this lecture we will present a short historical overview of different tracking detectors. Then we will describe currently used gaseous and silicon detectors and their performance. In the second part we will discuss how to estimate tracking precision, how to design a tracker and how the track finding works. After a short description of the LHC the main attention is drawn to the ALICE experiment since it is dedicated to study new states in hadronic matter at the LHC. The ALICE tracking procedure is discussed in detail. A comparison to the tracking in ATLAS, CMS and LHCb is given. (5 refs).

  2. Investigation of Iron-based double perovskite oxides on the magnetic phase stability, mechanical, electronic and optical properties via first-principles calculation

    International Nuclear Information System (INIS)

    Rached, H.; Bendaoudia, S.; Rached, D.

    2017-01-01

    The main goal of the present work is to obtain report on the magnetic phase stability, mechanical, electronic and optical properties of double perovskite oxides Pb 2 FeMO 6 (M = Mo, Re and W) by employing the ab-initio plane-wave method, based on the density functional theory (DFT). The exchange-correlation (XC) energy of electrons was treated using the Perdew–Burke–Ernzerhof parametrization. The ground-state electronic properties for different magnetic configurations were calculated. The formation enthalpies has been evaluated in order to determinate the stability of our compounds. The independent elastic constants and the related mechanical properties are investigated. The electronic structure calculation reveal the half-metallic ferrimagnets (FiM-HM) for all investigated compounds. The optical constants as the dielectric function, refractive index, optical reflectivity and absorption coefficient were calculated and discussed in detail. Therefore, our compounds are identified as potential candidates for spintronic applications and high performance electronic devices. - Highlights: • Based on the DFT calculation, the Pb 2 FeMO 6 (M = Mo, Re and W) compounds have been investigated. • The ground-state properties are predicted. • The mechanical properties reveals that these compounds are stable against any elastic deformations. • The electronic structures reveals the half-metallic ferrimagnets (FiM-HM) for all investigated compounds.

  3. Investigation of Iron-based double perovskite oxides on the magnetic phase stability, mechanical, electronic and optical properties via first-principles calculation

    Energy Technology Data Exchange (ETDEWEB)

    Rached, H., E-mail: habib_rached@yahoo.fr [Laboratoire des Matériaux Magnétiques, Faculté des Sciences Exactes, Université Djillali Liabès de Sidi Bel-Abbès, Sidi Bel-Abbès, 22000 (Algeria); Département de Physique, Faculté des Sciences Exactes et Informatique, Université Hassiba BenBouali de Chlef, Chlef, 02000 (Algeria); Bendaoudia, S. [Laboratoire des Matériaux Magnétiques, Faculté des Sciences Exactes, Université Djillali Liabès de Sidi Bel-Abbès, Sidi Bel-Abbès, 22000 (Algeria); Rached, D., E-mail: rachdj@yahoo.fr [Laboratoire des Matériaux Magnétiques, Faculté des Sciences Exactes, Université Djillali Liabès de Sidi Bel-Abbès, Sidi Bel-Abbès, 22000 (Algeria)

    2017-06-01

    The main goal of the present work is to obtain report on the magnetic phase stability, mechanical, electronic and optical properties of double perovskite oxides Pb{sub 2}FeMO{sub 6} (M = Mo, Re and W) by employing the ab-initio plane-wave method, based on the density functional theory (DFT). The exchange-correlation (XC) energy of electrons was treated using the Perdew–Burke–Ernzerhof parametrization. The ground-state electronic properties for different magnetic configurations were calculated. The formation enthalpies has been evaluated in order to determinate the stability of our compounds. The independent elastic constants and the related mechanical properties are investigated. The electronic structure calculation reveal the half-metallic ferrimagnets (FiM-HM) for all investigated compounds. The optical constants as the dielectric function, refractive index, optical reflectivity and absorption coefficient were calculated and discussed in detail. Therefore, our compounds are identified as potential candidates for spintronic applications and high performance electronic devices. - Highlights: • Based on the DFT calculation, the Pb{sub 2}FeMO{sub 6} (M = Mo, Re and W) compounds have been investigated. • The ground-state properties are predicted. • The mechanical properties reveals that these compounds are stable against any elastic deformations. • The electronic structures reveals the half-metallic ferrimagnets (FiM-HM) for all investigated compounds.

  4. The study of nuclear tracks in crystals

    International Nuclear Information System (INIS)

    Perelygin, V.P.

    1993-01-01

    The problem of fast heavy nuclei track registration and track stability in natural and artificial crystals is generally discussed in the frame of four - zone model of tracks, first suggested in 1972. The results on sensitivity calibrations of the crystals, the efficiency of particle registration, the sources of background, the thermal stability of latent tracks, the uranium content in crystals are reviewed. The data on tracks age and fossil galactic cosmic ray nuclei tracks in crystals provide a very important information about the nucleosynthesis processes in our Galaxy, about the history of the Earth and about the charge and energy spectra of cosmic ray nuclei with Z > 26 averaged over time intervals up to 200 M.Y. The dependence of volume etchable track length (VETL) on threshold annealing procedure and track orientation in crystal lattice suppose to be very important for fossil and fresh track studies. (Author)

  5. Optical Airborne Tracker System

    Data.gov (United States)

    National Aeronautics and Space Administration — The Optical Airborne Tracker System (OATS) is an airborne dual-axis optical tracking system capable of pointing at any sky location or ground target.  The objectives...

  6. Quantifying skin motion artifact error of the hindfoot and forefoot marker clusters with the optical tracking of a multi-segment foot model using single-plane fluoroscopy.

    Science.gov (United States)

    Shultz, R; Kedgley, A E; Jenkyn, T R

    2011-05-01

    The trajectories of skin-mounted markers tracked with optical motion capture are assumed to be an adequate representation of the underlying bone motions. However, it is well known that soft tissue artifact (STA) exists between marker and bone. This study quantifies the STA associated with the hindfoot and midfoot marker clusters of a multi-segment foot model. To quantify STA of the hindfoot and midfoot marker clusters with respect to the calcaneus and navicular respectively, fluoroscopic images were collected on 27 subjects during four quasi-static positions, (1) quiet standing (non-weight bearing), (2) at heel strike (weight-bearing), (3) at midstance (weight-bearing) and (4) at toe-off (weight-bearing). The translation and rotation components of STA were calculated in the sagittal plane. Translational STA at the calcaneus varied from 5.9±7.3mm at heel-strike to 12.1±0.3mm at toe-off. For the navicular the translational STA ranged from 7.6±7.6mm at heel strike to 16.4±16.7mm at toe-off. Rotational STA was relatively smaller for both bones at all foot positions. For the calcaneus they varied between 0.1±2.2° at heel-strike to 0.2±0.6° at toe-off. For the navicular, the rotational STA ranged from 0.6±0.9° at heel-strike to 0.7±0.7° at toe-off. The largest translational STA found in this study (16mm for the navicular) was smaller than those reported in the literature for the thigh and the lower leg, but was larger than the STA of individual spherical markers affixed to the foot. The largest errors occurred at toe-off position for all subjects for both the hindfoot and midfoot clusters. Future studies are recommended to quantify true three-dimensional STA of the entire foot during gait. Copyright © 2011. Published by Elsevier B.V.

  7. Optical tunability of magnetic polaron stability in single-Mn doped bulk GaAs and GaAs/AlGaAs quantum dots

    Science.gov (United States)

    Qu, Fanyao; Moura, Fábio Vieira; Alves, Fabrizio M.; Gargano, Ricardo

    2013-03-01

    Optical control of magnetic property of a magnetic polaron (MP) in Mn-doped bulk GaAs and GaAs/AlGaAs quantum dots (QDs) have been studied. We have developed basis optimization technique for the method of linear combination of atomic orbitals (LCAOs), which significantly improve the accuracy of the conventional LCAO calculation. We have demonstrated that a monochromatic, linearly polarized, intense pulsed laser field induces a collapse of the MP and an ionization of Mn-acceptor in Mn-doped GaAs materials due to a dichotomy of hole wave function. We find this optical tunability of MP stability can be adjusted by confinement introduced in GaAs QDs.

  8. Femtosecond stabilization of optical fiber links based on RF power detection; Femtosekundengenaue Stabilisierung von optischen Glasfaserstrecken basierend auf HF-Leistungsmessung

    Energy Technology Data Exchange (ETDEWEB)

    Lamb, Thorsten

    2011-01-15

    X-ray light sources like the free electron laser FLASH in Hamburg or the future XFEL generate light pulses with durations in the order of a few ten femtoseconds. To fulfill the requirements for the synchronisation of various components on this timescale, optical synchronisation systems are already successfully used. In this diploma thesis a novel photodiode-based, detection principle for the measurement of drifts in the optical links of such a synchronisation system is developed. The detection principle is nearly drift-free and highly robust. It is demonstrated that the long term stability of the assembled detector over 33 h is below 5 fs (peak to peak) at a standard deviation of 0.86 fs. Furthermore, an active stabilisation of a fibre link using this detector is successfully achieved. (orig.)

  9. Two-Stage System Based on a Software-Defined Radio for Stabilizing of Optical Frequency Combs in Long-Term Experiments

    Czech Academy of Sciences Publication Activity Database

    Čížek, Martin; Hucl, Václav; Hrabina, Jan; Šmíd, Radek; Mikel, Břetislav; Lazar, Josef; Číp, Ondřej

    2014-01-01

    Roč. 14, č. 1 (2014), s. 1757-1770 ISSN 1424-8220 R&D Projects: GA ČR GPP102/11/P819; GA ČR GAP102/10/1813; GA MŠk ED0017/01/01; GA MŠk EE2.4.31.0016 Institutional support: RVO:68081731 Keywords : optical frequency combs * digital signal processing * software-defined radio * beat note * stabilization * long-term operation Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 2.245, year: 2014

  10. Application of MEMS gyroscopes and accelerometers in FSM stabilization

    Science.gov (United States)

    Tian, Jing; Yang, Wenshu; Peng, Zhenming; Deng, Chao

    2015-10-01

    Gimbals and Fast steering mirrors (FSMs) are commonly used to stabilize the line-of-sight (LOS) of the electro-optical tracking system mounted on moving platforms .The gimbal is used to restrain the vibration of low frequencies, and the FSM is used to restrain the vibration of high frequencies. The restraining performance of the Electro-Optical tracking system is equal to the multiplication of the restraining performance of the gimbal and the FSM. The vibration of high frequencies is mainly restrained by the FSM, and so the performance of the FSM is very important to the Electro-Optical tracking system. There are two ways to improve the stabilization accuracy and bandwidth of the FSM, one way is to improve the accuracy and bandwidth of inertial sensors, and the other way is to use low weight inertial sensors to reduce the load of FSM and increase the mechanical resonance frequency. And so the inertial sensors of high accuracy, high bandwidth and low weight are the key to improve the stabilization accuracy and bandwidth of the FSM.

  11. Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) Instrument Improvements

    Science.gov (United States)

    Dunagan, Stephen E.; Redemann, Jens; Chang, Cecilia; Dahlgren, Robert; Fahey, Lauren; Flynn, Connor; Johnson, Roy; Kacenelenbogen, Meloe; Leblanc, Samuel; Liss, Jordan; hide

    2017-01-01

    The Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) combines airborne sun tracking and sky scanning with grating spectroscopy to improve knowledge of atmospheric constituents and their links to air-pollution and climate. Hyper-spectral measurements of direct-beam solar irradiance provide retrievals of gas constituents, aerosol optical depth, and aerosol and thin cloud optical properties. Sky radiance measurements in the principal and almucantar planes enhance retrievals of aerosol absorption, aerosol type, and size mode distribution. Zenith radiance measurements are used to retrieve cloud properties and phase, which in turn are used to quantify the radiative transfer below cloud layers. These airborne measurements tighten the closure between satellite and ground-based measurements. In contrast to the Ames Airborne Tracking Sunphotometer (AATS-14) predecessor instrument, new technologies for each subsystem have been incorporated into 4STAR. In particular, 4STAR utilizes a modular sun-trackingsky-scanning optical head with fiber optic signal transmission to rack mounted spectrometers, permitting miniaturization of the external optical head, and spectrometerdetector configurations that may be tailored for specific scientific objectives. This paper discusses technical challenges relating to compact optical collector design, radiometric dynamic range and stability, and broad spectral coverage at high resolution. Test results benchmarking the performance of the instrument against the AATS-14 standard and emerging science requirements are presented.

  12. Robotic vehicle with multiple tracked mobility platforms

    Science.gov (United States)

    Salton, Jonathan R [Albuquerque, NM; Buttz, James H [Albuquerque, NM; Garretson, Justin [Albuquerque, NM; Hayward, David R [Wetmore, CO; Hobart, Clinton G [Albuquerque, NM; Deuel, Jr., Jamieson K.

    2012-07-24

    A robotic vehicle having two or more tracked mobility platforms that are mechanically linked together with a two-dimensional coupling, thereby forming a composite vehicle of increased mobility. The robotic vehicle is operative in hazardous environments and can be capable of semi-submersible operation. The robotic vehicle is capable of remote controlled operation via radio frequency and/or fiber optic communication link to a remote operator control unit. The tracks have a plurality of track-edge scallop cut-outs that allow the tracks to easily grab onto and roll across railroad tracks, especially when crossing the railroad tracks at an oblique angle.

  13. Timber tracking

    DEFF Research Database (Denmark)

    Düdder, Boris; Ross, Omry

    2017-01-01

    Managing and verifying forest products in a value chain is often reliant on easily manipulated document or digital tracking methods - Chain of Custody Systems. We aim to create a new means of tracking timber by developing a tamper proof digital system based on Blockchain technology. Blockchain...

  14. Multifunctional role of rare earth doping in optical materials: nonaqueous sol-gel synthesis of stabilized cubic HfO2 luminescent nanoparticles.

    Science.gov (United States)

    Lauria, Alessandro; Villa, Irene; Fasoli, Mauro; Niederberger, Markus; Vedda, Anna

    2013-08-27

    In this work a strategy for the control of structure and optical properties of inorganic luminescent oxide-based nanoparticles is presented. The nonaqueous sol-gel route is found to be suitable for the synthesis of hafnia nanoparticles and their doping with rare earths (RE) ions, which gives rise to their luminescence either under UV and X-ray irradiation. Moreover, we have revealed the capability of the technique to achieve the low-temperature stabilization of the cubic phase through the effective incorporation of trivalent RE ions into the crystal lattice. Particular attention has been paid to doping with europium, causing a red luminescence, and with lutetium. Structure and morphology characterization by XRD, TEM/SEM, elemental analysis, and Raman/IR vibrational spectroscopies have confirmed the occurrence of the HfO2 cubic polymorph for dopant concentrations exceeding a threshold value of nominal 5 mol %, for either Lu(3+) or Eu(3+). The optical properties of the nanopowders were investigated by room temperature radio- and photoluminescence experiments. Specific features of Eu(3+) luminescence sensitive to the local crystal field were employed for probing the lattice modifications at the atomic scale. Moreover, we detected an intrinsic blue emission, allowing for a luminescence color switch depending on excitation wavelength in the UV region. We also demonstrate the possibility of changing the emission spectrum by multiple RE doping in minor concentration, while deputing the cubic phase stabilization to a larger concentration of optically inactive Lu(3+) ions. The peculiar properties arising from the solvothermal nonaqueous synthesis here used are described through the comparison with thermally treated powders.

  15. A survey of the signal stability and radiation dose response of sulfates in the context of adapting optical dating for Mars

    International Nuclear Information System (INIS)

    O'Connor, V.A.; Lepper, K.; Morken, T.O.; Thorstad, D.J.; Podoll, A.; Giles, M.J.

    2011-01-01

    The Martian landscape is currently dominated by eolian processes, and eolian dunes are a direct geomorphic expression of the dynamic interaction between the atmosphere and the lithosphere of planets. The timing, frequency, and spatial extent of dune mobility directly reflects changing climatic conditions, therefore, sedimentary depositional ages are important for understanding the paleoclimatic and geomorphologic history of features and processes present on the surface of the Earth or Mars. Optical dating is an established terrestrial dosimetric dating technique that is being developed for this task on Mars. Gypsum and anhydrite are two of the most stable and abundant sulfate species found on the Earth, and they have been discovered in Martian sediments along with various magnesium sulfates and jarosite. In this study, the optical dating properties of various Ca-, Mg-, and Fe-bearing sulfates were documented to help evaluate the influence they may have on in-situ optical dating in eolian environments on Mars. Single-aliquot regenerative-dose (SAR) experimental procedures have been adapted to characterize the radiation dose response and signal stability of the Martian sulfate analogs. Jarosite was dosimetrically inert in our experiments. The radiation dose response of the Ca- and Mg-sulfates was monotonically increasing in all cases with characteristic doses ranging from ∼100 to ∼1000 Gy. Short-term signal fading also varied considerably in the Ca- and Mg-sulfates ranging from ∼0% to ∼40% per decade for these materials. These results suggest that the OSL properties of Ca- and Mg-sulfates will need to be considered when developing protocols for in-situ optical dating on Mars, but more enticingly, our results foreshadow the potential for gypsum to be developed as a geochronometer for Mars or the Earth. - Highlights: → The radiation dose response and OSL signal stability of Ca- and Mg-sulfates was highly variable. → OSL properties of Ca- and Mg

  16. The effect of oxygen vacancies on the stability, electronic and optical properties of the ZnAl2O4(100) surface; A first-principles study

    Science.gov (United States)

    Lahmer, M. A.

    2018-03-01

    The effect of oxygen vacancy formation on the stability, structural, electronic, and optical properties of the ZnAl2O4(100) surface was investigated by using the first-principles method. The obtained results show that, in the case of the Free-defect surface, the AlO2-terminated surface is more stable than the Zn-terminated surface. The results of structural relaxation show that, for each surface termination, the interlayer distances near the surface oscillate in a damping style. In addition, the work function values and the optical properties of these two surfaces are quite different. Our results show that the work function of the Zn-terminated surface is at least 2 times smaller than that of the AlO2 surface. On the other hand, ab initio thermodynamic calculations show that the O reduction occurs in the case of the AlO2 surface under all growth conditions, while, there is no evidence for O reduction in the case of the Zn-terminated surface. Our results show also that neutral oxygen vacancies can affect greatly the electronic and optical properties of the ZnAl2O4(100) surface.

  17. Nonlinear optical and G-Quadruplex DNA stabilization properties of novel mixed ligand copper(II) complexes and coordination polymers: Synthesis, structural characterization and computational studies

    Science.gov (United States)

    Rajasekhar, Bathula; Bodavarapu, Navya; Sridevi, M.; Thamizhselvi, G.; RizhaNazar, K.; Padmanaban, R.; Swu, Toka

    2018-03-01

    The present study reports the synthesis and evaluation of nonlinear optical property and G-Quadruplex DNA Stabilization of five novel copper(II) mixed ligand complexes. They were synthesized from copper(II) salt, 2,5- and 2,3- pyridinedicarboxylic acid, diethylenetriamine and amide based ligand (AL). The crystal structure of these complexes were determined through X-ray diffraction and supported by ESI-MAS, NMR, UV-Vis and FT-IR spectroscopic methods. Their nonlinear optical property was studied using Gaussian09 computer program. For structural optimization and nonlinear optical property, density functional theory (DFT) based B3LYP method was used with LANL2DZ basis set for metal ion and 6-31G∗ for C,H,N,O and Cl atoms. The present work reveals that pre-polarized Complex-2 showed higher β value (29.59 × 10-30e.s.u) as compared to that of neutral complex-1 (β = 0.276 × 10-30e.s.u.) which may be due to greater advantage of polarizability. Complex-2 is expected to be a potential material for optoelectronic and photonic technologies. Docking studies using AutodockVina revealed that complex-2 has higher binding energy for both G-Quadruplex DNA (-8.7 kcal/mol) and duplex DNA (-10.1 kcal/mol). It was also observed that structure plays an important role in binding efficiency.

  18. ultra-Stable Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (5STAR)

    Science.gov (United States)

    Dunagan, S. E.; Johnson, R. R.; Redemann, J.; Holben, B. N.; Schmid, B.; Flynn, C. J.; Fahey, L.; LeBlanc, S. E.; Liss, J.; Kacenelenbogen, M. S.; Segal-Rosenhaimer, M.; Shinozuka, Y.; Dahlgren, R. P.; Pistone, K.; Karol, Y.

    2017-12-01

    The Spectrometer for Sky-Scanning, Sun-Tracking Atmospheric Research (4STAR) combines airborne sun tracking and sky scanning with diffraction spectroscopy to improve knowledge of atmospheric constituents and their links to air pollution and climate. Direct beam hyperspectral measurement of optical depth improves retrievals of gas constituents and determination of aerosol properties. Sky scanning enhances retrievals of aerosol type and size distribution. Hyperspectral cloud-transmitted radiance measurements enable the retrieval of cloud properties from below clouds. These measurements tighten the closure between satellite and ground-based measurements. 4STAR incorporates a modular sun-tracking/ sky-scanning optical head with optical fiber signal transmission to rack mounted spectrometers, permitting miniaturization of the external optical tracking head, and future detector evolution. 4STAR has supported a broad range of flight experiments since it was first flown in 2010. This experience provides the basis for a series of improvements directed toward reducing measurement uncertainty and calibration complexity, and expanding future measurement capabilities, to be incorporated into a new 5STAR instrument. A 9-channel photodiode radiometer with AERONET-matched bandpass filters will be incorporated to improve calibration stability. A wide dynamic range tracking camera will provide a high precision solar position tracking signal as well as an image of sky conditions around the solar axis. An ultrasonic window cleaning system design will be tested. A UV spectrometer tailored for formaldehyde and SO2 gas retrievals will be added to the spectrometer enclosure. Finally, expansion capability for a 4 channel polarized radiometer to measure the Stokes polarization vector of sky light will be incorporated. This paper presents initial progress on this next-generation 5STAR instrument. Keywords: atmosphere; climate; pollution; radiometry; technology; hyperspectral; fiber optic

  19. First-principles study of structural stability, electronic, optical and elastic properties of binary intermetallic: PtZr

    Energy Technology Data Exchange (ETDEWEB)

    Pagare, Gitanjali, E-mail: gita-pagare@yahoo.co.in [Department of Physics, Sarojini Naidu Government Girls P. G. Autonomous College, Bhopal-462016 (India); Jain, Ekta, E-mail: jainekta05@gmail.com [Department of Physics, Government M. L. B. Girls P. G. Autonomous College, Bhopal-462002 (India); Sanyal, S. P., E-mail: sps.physicsbu@gmail.com [Department of Physics, Barkatullah University, Bhopal-462026 (India)

    2016-05-06

    Structural, electronic, optical and elastic properties of PtZr have been studied using the full-potential linearized augmented plane wave (FP-LAPW) method within density functional theory (DFT). The energy against volume and enthalpy vs. pressure variation in three different structures i.e. B{sub 1}, B{sub 2} and B{sub 3} for PtZr has been presented. The equilibrium lattice parameter, bulk modulus and its pressure derivative have been obtained using optimization method for all the three phases. Furthermore, electronic structure was discussed to reveal the metallic character of the present compound. The linear optical properties are also studied under zero pressure for the first time. Results on elastic properties are obtained using generalized gradient approximation (GGA) for exchange correlation potentials. Ductile nature of PtZr compound is predicted in accordance with Pugh’s criteria.

  20. Laser frequency stabilization and control of optical cavities with suspended mirrors for the VIRGO interferometric detector of gravitational waves

    International Nuclear Information System (INIS)

    Barsuglia, Matteo

    1999-01-01

    The VIRGO detector is an interferometer with 3 km Fabry-Perot cavities in the arms. It is aimed at the detection of gravitational radiation emitted by astrophysical sources. This thesis comprises two independent parts. The first part is devoted to the laser frequency stabilization. In the second one we present a study of a suspended cavity. We determine the impact of laser frequency fluctuations on the overall VIRGO sensitivity. We study the frequency stabilization of the interferometer considered as an ultra-stable standard and we evaluate the noise pertaining to different signals taken into consideration. A strategy of control is discussed. We then study the VIRGO mode-cleaner prototype, a 30 m suspended triangular cavity, for which we have developed a control in order to keep it locked. Finally, we characterize this cavity in terms of mode spectra, finesse and mechanical transfer functions. (author)

  1. Water-Soluble N-Heterocyclic Carbene-Protected Gold Nanoparticles: Size-Controlled Synthesis, Stability, and Optical Properties

    OpenAIRE

    Salorinne, Kirsi; Man, Renee W.Y.; Li, Chien-Hung; Taki, Masayasu; Nambo, Masakazu; Crudden, Cathleen M.

    2017-01-01

    NHC-Au(I) complexes were used to prepare stable, water-soluble, NHC-protected gold nanoparticles. The water-soluble, charged nature of the nanoparticles permitted analysis by polyacrylamide gel electrophoresis (PAGE), which showed that the nanoparticles were highly monodisperse, with tunable core diameters between 2.0 and 3.3 nm depending on the synthesis conditions. Temporal, thermal, and chemical stability of the nanoparticles were determined to be high. Treatment with thiols caused etching...

  2. Cu Microbelt Network Embedded in Colorless Polyimide Substrate: Flexible Heater Platform with High Optical Transparency and Superior Mechanical Stability.

    Science.gov (United States)

    Lee, Ji-Hyun; Youn, Doo-Young; Luo, Zhenhao; Moon, Ji Young; Choi, Seon-Jin; Kim, Chanhoon; Kim, Il-Doo

    2017-11-15

    Metal nanowires have been considered as essential components for flexible transparent conducting electrodes (TCEs) with high transparency and low sheet resistance. However, large surface roughness and high interwire junction resistance limit the practical use of metal wires as TCEs. Here, we report Cu microbelt network (Cu MBN) with coalescence junction and low surface roughness for next-generation flexible TCEs. In particular, the unique embedded structure of Cu MBN in colorless polyimide (cPI) film was achieved to reduce the surface roughness as well as enhance mechanical stability. The TCEs using junction-free Cu MBN embedded in cPI exhibited excellent mechanical stability up to 100 000 bending cycles, high transparency of 95.18%, and a low sheet resistance of 6.25 Ω sq -1 . Highly robust Cu MBN-embedded cPI-based TCE showed outstanding flexible heater performance, i.e., high saturation temperature (120 °C) at very low voltage (2.3 V), owing to the high thermal stability of cPI and excellent thermal conductivity of the Cu MBN.

  3. Analysis of focusing error signals by differential astigmatic method under off-center tracking in the land-groove-type optical disk

    Science.gov (United States)

    Shinoda, Masahisa; Nakatani, Hidehiko

    2015-04-01

    We theoretically calculate the behavior of the focusing error signal in the land-groove-type optical disk when the objective lens traverses on out of the radius of the optical disk. The differential astigmatic method is employed instead of the conventional astigmatic method for generating the focusing error signals. The signal behaviors are compared and analyzed in terms of the gain difference of the slope sensitivity of the focusing error signals from the land and the groove. In our calculation, the format of digital versatile disc-random access memory (DVD-RAM) is adopted as the land-groove-type optical disk model, and advantageous conditions for suppressing the gain difference are investigated. The calculation method and results described in this paper will be reflected in the next generation land-groove-type optical disks.

  4. The Bering Target Tracking Instrumentation

    DEFF Research Database (Denmark)

    Denver, Troelz; Jørgensen, John Leif; Betto, Maurizio

    2003-01-01

    's pointing direction. To achieve fast tracking over a large solid angle, the telescope pointing is achieved by means of a folding mirror in the optical pathway. When a prospective target approaches the telescope FOV, the ASC on the secondary will guide the folding mirror into position such that the target...... is inside the telescope FOV. During the telescope observation time, the ASC will constantly control the folding mirror to correctly position the target at the center of the telescope, basically performing a standard telescope tracking service. The telescope will alter the initial target acquisition track...

  5. Modulation stability and optical soliton solutions of nonlinear Schrödinger equation with higher order dispersion and nonlinear terms and its applications

    Science.gov (United States)

    Arshad, Muhammad; Seadawy, Aly R.; Lu, Dianchen

    2017-12-01

    In optical fibers, the higher order non-linear Schrödinger equation (NLSE) with cubic quintic nonlinearity describes the propagation of extremely short pulses. We constructed bright and dark solitons, solitary wave and periodic solitary wave solutions of generalized higher order NLSE in cubic quintic non Kerr medium by applying proposed modified extended mapping method. These obtained solutions have key applications in physics and mathematics. Moreover, we have also presented the formation conditions on solitary wave parameters in which dark and bright solitons can exist for this media. We also gave graphically the movement of constructed solitary wave and soliton solutions, that helps to realize the physical phenomena's of this model. The stability of the model in normal dispersion and anomalous regime is discussed by using the modulation instability analysis, which confirms that all constructed solutions are exact and stable. Many other such types of models arising in applied sciences can also be solved by this reliable, powerful and effective method.

  6. Synthesis, characterization and optical studies of highly luminescent ZnS nanoparticles associated with hypromellose matrix as a green and novel stabilizer.

    Science.gov (United States)

    Tiwari, Ashish; Khan, S A; Kher, R S; Dhoble, S J

    2014-09-01

    ZnS nanoparticles stabilized by a carbohydrate-based matrix, hypromellose (hydroxypropyl methylcellulose) were prepared via a wet chemical method. The nanocomposite was characterized by X-ray diffraction, transmission electon microscopy and Fourier transform infrared spectroscopy. X-Ray diffraction patterns revealed a zinc blende structure. Thermogravimetric analysis suggested that polymer attached to the surface decomposes at 700 °C. Absorption measurements were carried out and calculation of the diameter polydispersity index (DPI) suggests the formation of monodisperse nanoparticles. The optical properties of the as-prepared samples were studied by UV/vis spectroscopy and steady-state photoluminescence (PL) spectroscopy. The PL studies indicate the applicability of these nanoparticles as biocompatible sensors or luminescence markers in future. Copyright © 2013 John Wiley & Sons, Ltd.

  7. Ultralow-jitter passive timing stabilization of a mode-locked Er-doped fiber laser by injection of an optical pulse train.

    Science.gov (United States)

    Yoshitomi, Dai; Kobayashi, Yohei; Kakehata, Masayuki; Takada, Hideyuki; Torizuka, Kenji; Onuma, Taketo; Yokoi, Hideki; Sekiguchi, Takuro; Nakamura, Shinki

    2006-11-15

    The pulse timing of a mode-locked Er-doped fiber laser was stabilized to a reference pulse train from a Cr:forsterite mode-locked laser by all-optical passive synchronization scheme. The reference pulses were injected into a ring cavity of the fiber laser by using a 1.3-1.5 mum wavelength-division multiplexer. The spectral shift induced by cross-phase modulation between copropagating two-color pulses realizes self-synchronization due to intracavity group-delay dispersion. The rms integration of timing jitter between the fiber laser pulse and the reference pulse was 3.7 fs in a Fourier frequency range from 1 Hz to 100 kHz.

  8. A collective variable approach and stabilization for dispersion-managed optical solitons in the quintic complex Ginzburg-Landau equation as perturbations of the nonlinear Schroedinger equation

    International Nuclear Information System (INIS)

    Fewo, S I; Kenfack-Jiotsa, A; Kofane, T C

    2006-01-01

    With the help of the one-dimensional quintic complex Ginzburg-Landau equation (CGLE) as perturbations of the nonlinear Schroedinger equation (NLSE), we derive the equations of motion of pulse parameters called collective variables (CVs), of a pulse propagating in dispersion-managed (DM) fibre optic links. The equations obtained are investigated numerically in order to view the evolution of pulse parameters along the propagation distance, and also to analyse effects of initial amplitude and width on the propagating pulse. Nonlinear gain is shown to be beneficial in stabilizing DM solitons. A fully numerical simulation of the one-dimensional quintic CGLE as perturbations of NLSE finally tests the results of the CV theory. A good agreement is observed between both methods

  9. A computer program TRACK_P for studying proton tracks in PADC detectors

    Science.gov (United States)

    Nikezic, D.; Ivanovic, M.; Yu, K. N.

    A computer program for studying proton tracks in solid state nuclear track detectors was developed and described in this paper. The program was written in Fortran 90, with an additional tool for visualizing the track appearance as seen under the optical microscope in the transmission mode, which was written in the Python programming language. Measurable track parameters were determined and displayed in the application window and written in a data file. Three-dimensional representation of tracks was enabled. Examples of calculated tracks were also given in the present paper.

  10. A computer program TRACK_P for studying proton tracks in PADC detectors

    Directory of Open Access Journals (Sweden)

    D. Nikezic

    2016-01-01

    Full Text Available A computer program for studying proton tracks in solid state nuclear track detectors was developed and described in this paper. The program was written in Fortran 90, with an additional tool for visualizing the track appearance as seen under the optical microscope in the transmission mode, which was written in the Python programming language. Measurable track parameters were determined and displayed in the application window and written in a data file. Three-dimensional representation of tracks was enabled. Examples of calculated tracks were also given in the present paper.

  11. Track buckling prevention : theory, safety concepts, and applications

    Science.gov (United States)

    2013-03-31

    This report is a part of the John A. Volpe National Transportation Systems Centers Track Stability Research Program for the Federal Railroad Administration on thermal buckling of continuous welded rail (CWR) track and its prevention. Presented in ...

  12. Risk analysis based CWR track buckling safety evaluations

    Science.gov (United States)

    2001-01-01

    As part of the Federal Railroad Administrations (FRA) track systems research program, the US DOTS Volpe Center is conducting analytic and experimental investigations to evaluate track lateral strength and stability limits for improved safety an...

  13. Effect of foundation flexibility on the vibrational stability of the National Ignition Facility optical system support structures

    International Nuclear Information System (INIS)

    McCallen, D.

    1997-01-01

    Alignment requirements for the National Ignition Facility (NIF) optical components will require a number of support structures which minimize the system displacements and deformations. The stringent design requirements for this facility will result in a system in which vibrations due to ambient environmental loads (e.g. foundation motion due to typical traffic loads, microseisms or nearby equipment) will have a significant, and perhaps predominant, influence on the design of the supporting structures. When considering the total deformations and displacements of the structural systems, the contribution of the foundation to the overall system flexibility must be addressed. Classical fixed-base structural analyses, which are predicated on an assumption of an infinitely rigid foundation system, neglect the influence of foundation flexibility and for the vibration regime in which the NIF structures reside, may result in significant underestimation of the system ambient vibration displacements. In the work described herein, parametric studies were performed in order to understand the potential contributions of soil-structure- interaction (SSI) to optical system displacements. Time domain finite element analyses were employed to quantify the effect of wave scattering by the mat foundation and the effects of inertial SSI due to the rocking of the massive shear wall support structures. A simplified procedure is recommended for accounting for SSI effects in the design of the special equipment structures. The simplified approach consists of applying a scale factor to displacements obtained from fixed base analyses to approximately account for the effects of soil-structure interaction and variable support input motion

  14. Poly(methyl methacrylate)/layered zinc sulfide nanocomposites: Preparation, characterization and the improvements in thermal stability, flame retardant and optical properties

    International Nuclear Information System (INIS)

    Wang, Biao; Zhou, Keqing; Jiang, Saihua; Shi, Yongqian; Wang, Bibo; Gui, Zhou; Hu, Yuan

    2014-01-01

    Highlights: • Layered zinc sulfide (LZnS) was synthesized successfully via hydrothermal method. • We prepare PMMA/LZnS nanocomposites by in situ bulk polymerization of MMA. • PMMA/LZnS nanocomposites were investigated by TGA, DSC, MCC, UV–vis and PL test. • The thermal stability, flame retardant and optical properties of PMMA are improved. - Abstract: Layered zinc sulfide (LZnS) was synthesized successfully via hydrothermal method and poly(methyl methacrylate) (PMMA)/layered zinc sulfide nanocomposites were obtained by in situ bulk polymerization of methyl methacrylate (MMA). X-ray diffraction (XRD) and transmission electron microscopy (TEM) were used to characterize the as-synthesized layered zinc sulfide and PMMA/layered zinc sulfide nanocomposites. Microscale combustion calorimeter (MCC), differential scanning calorimeter (DSC) and thermogravimetric analysis (TGA) were used to test the thermal properties of the composites. Ultraviolet visible (UV–vis) transmittance spectra and photoluminence (PL) spectra were obtained to investigate the optical properties of the composites. From the results, the thermal degradation temperature is increased by 20–50 °C, the peak of heat release rate (pHRR) and total heat release (THR) are both decreased by above 30%, and the photoluminence intensity is enhanced with the increasing loading of layered zinc sulfide

  15. Ordered Arrangement and Optical Properties of Silica-Stabilized Gold Nanoparticle-PNIPAM Core-Satellite Clusters for Sensitive Raman Detection.

    Science.gov (United States)

    Herrmann, Janning F; Kretschmer, Florian; Hoeppener, Stephanie; Höppener, Christiane; Schubert, Ulrich S

    2017-10-01

    Gold-polymer hybrid nanoparticles attract wide interest as building blocks for the engineering of photonic materials and plasmonic (active) metamaterials with unique optical properties. In particular, the coupling of the localized surface plasmon resonances of individual metal nanostructures in the presence of nanometric gaps can generate highly enhanced and confined electromagnetic fields, which are frequently exploited for metal-enhanced light-matter interactions. The optical properties of plasmonic structures can be tuned over a wide range of properties by means of their geometry and the size of the inserted nanoparticles as well as by the degree of order upon assembly into 1D, 2D, or 3D structures. Here, the synthesis of silica-stabilized gold-poly(N-isopropylacrylamide) (SiO 2 -Au-PNIPAM) core-satellite superclusters with a narrow size distribution and their incorporation into ordered self-organized 3D assemblies are reported. Significant alterations of the plasmon resonance are found for different assembled structures as well as strongly enhanced Raman signatures are observed. In a series of experiments, the origin of the highly enhanced signals can be assigned to the interlock areas of adjacent SiO 2 -Au-PNIPAM core-satellite clusters and their application for highly sensitive nanoparticle-enhanced Raman spectroscopy is demonstrated. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Poly(methyl methacrylate)/layered zinc sulfide nanocomposites: Preparation, characterization and the improvements in thermal stability, flame retardant and optical properties

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Biao; Zhou, Keqing; Jiang, Saihua [State Key Laboratory of Fire Science, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui 230026 (China); Shi, Yongqian [State Key Laboratory of Fire Science, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui 230026 (China); Suzhou Key Laboratory of Urban Public Safety, Suzhou Institute for Advanced Study, University of Science and Technology of China, 166 Ren’ai Road, Suzhou, Jiangsu 215123 (China); Wang, Bibo [State Key Laboratory of Fire Science, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui 230026 (China); Gui, Zhou, E-mail: zgui@ustc.edu.cn [State Key Laboratory of Fire Science, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui 230026 (China); Hu, Yuan, E-mail: yuanhu@ustc.edu.cn [State Key Laboratory of Fire Science, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui 230026 (China); Suzhou Key Laboratory of Urban Public Safety, Suzhou Institute for Advanced Study, University of Science and Technology of China, 166 Ren’ai Road, Suzhou, Jiangsu 215123 (China)

    2014-08-15

    Highlights: • Layered zinc sulfide (LZnS) was synthesized successfully via hydrothermal method. • We prepare PMMA/LZnS nanocomposites by in situ bulk polymerization of MMA. • PMMA/LZnS nanocomposites were investigated by TGA, DSC, MCC, UV–vis and PL test. • The thermal stability, flame retardant and optical properties of PMMA are improved. - Abstract: Layered zinc sulfide (LZnS) was synthesized successfully via hydrothermal method and poly(methyl methacrylate) (PMMA)/layered zinc sulfide nanocomposites were obtained by in situ bulk polymerization of methyl methacrylate (MMA). X-ray diffraction (XRD) and transmission electron microscopy (TEM) were used to characterize the as-synthesized layered zinc sulfide and PMMA/layered zinc sulfide nanocomposites. Microscale combustion calorimeter (MCC), differential scanning calorimeter (DSC) and thermogravimetric analysis (TGA) were used to test the thermal properties of the composites. Ultraviolet visible (UV–vis) transmittance spectra and photoluminence (PL) spectra were obtained to investigate the optical properties of the composites. From the results, the thermal degradation temperature is increased by 20–50 °C, the peak of heat release rate (pHRR) and total heat release (THR) are both decreased by above 30%, and the photoluminence intensity is enhanced with the increasing loading of layered zinc sulfide.

  17. Control Design and Digital Implementation of a Fast 2-Degree-of-Freedom Translational Optical Image Stabilizer for Image Sensors in Mobile Camera Phones.

    Science.gov (United States)

    Wang, Jeremy H-S; Qiu, Kang-Fu; Chao, Paul C-P

    2017-10-13

    This study presents design, digital implementation and performance validation of a lead-lag controller for a 2-degree-of-freedom (DOF) translational optical image stabilizer (OIS) installed with a digital image sensor in mobile camera phones. Nowadays, OIS is an important feature of modern commercial mobile camera phones, which aims to mechanically reduce the image blur caused by hand shaking while shooting photos. The OIS developed in this study is able to move the imaging lens by actuating its voice coil motors (VCMs) at the required speed to the position that significantly compensates for imaging blurs by hand shaking. The compensation proposed is made possible by first establishing the exact, nonlinear equations of motion (EOMs) for the OIS, which is followed by designing a simple lead-lag controller based on established nonlinear EOMs for simple digital computation via a field-programmable gate array (FPGA) board in order to achieve fast response. Finally, experimental validation is conducted to show the favorable performance of the designed OIS; i.e., it is able to stabilize the lens holder to the desired position within 0.02 s, which is much less than previously reported times of around 0.1 s. Also, the resulting residual vibration is less than 2.2-2.5 μm, which is commensurate to the very small pixel size found in most of commercial image sensors; thus, significantly minimizing image blur caused by hand shaking.

  18. Inductively coupled plasma optical emission spectrometry for trace multi-element determination in vegetable oils, margarine and butter after stabilization with propan-1-ol and water

    Science.gov (United States)

    de Souza, Roseli M.; Mathias, Bárbara M.; da Silveira, Carmem Lúcia P.; Aucélio, Ricardo Q.

    2005-06-01

    The quantitative evaluation of trace elements in foodstuffs is of considerable interest due to the potential toxicity of many elements, and because the presence of some metallic species might affect the overall quality (flavor and stability) of these products. In the present work, an inductively coupled plasma optical emission spectrometric method has been developed for the determination of six elements (Cd, Co, Cr, Cu, Ni and Mn) in olive oil, soy oil, margarine and butter. Organic samples (oils and fats) were stabilized using propan-1-ol and water, which enabled long-time sample dispersion in the solution. This simple sample preparation procedure, together with an efficient sample introduction strategy (using a Meinhard K3 nebulizer and a twister cyclonic spray chamber), facilitated the overall analytical procedure, allowing quantification using calibration curves prepared with inorganic standards. Internal standardization (Sc) was used for correction of matrix effects and signal fluctuations. Good sensitivities with limits of detection in the ng g -1 range were achieved for all six elements. These sensitivities were appropriate for the intended application. The method was tested through the analysis of laboratory-fortified samples with good recoveries (between 91.3% and 105.5%).

  19. Dynamic kirigami structures for integrated solar tracking

    Science.gov (United States)

    Lamoureux, Aaron; Lee, Kyusang; Shlian, Matthew; Forrest, Stephen R.; Shtein, Max

    2015-01-01

    Optical tracking is often combined with conventional flat panel solar cells to maximize electrical power generation over the course of a day. However, conventional trackers are complex and often require costly and cumbersome structural components to support system weight. Here we use kirigami (the art of paper cutting) to realize novel solar cells where tracking is integral to the structure at the substrate level. Specifically, an elegant cut pattern is made in thin-film gallium arsenide solar cells, which are then stretched to produce an array of tilted surface elements which can be controlled to within ±1°. We analyze the combined optical and mechanical properties of the tracking system, and demonstrate a mechanically robust system with optical tracking efficiencies matching conventional trackers. This design suggests a pathway towards enabling new applications for solar tracking, as well as inspiring a broader range of optoelectronic and mechanical devices. PMID:26348820

  20. Efficient radical cation stabilization of PANI-ZnO and PANI-ZnO-GO composites and its optical activity

    Energy Technology Data Exchange (ETDEWEB)

    Mathavan, T., E-mail: tjmathavan@gmail.com; Divya, A.; Benial, A. Milton Franklin [PG & Research Department of Physics, N.M.S.S.Vellaichamy Nadar College, Madurai-625 019 (India); Archana, J. [Research Institute of Engineering, Shizuoka University (Japan); Ramasubbu, A. [PG & Research Department of Chemistry, Govt. Arts College, Coimbatore (India); Jothirajan, M. A. [Research Department of Physics, Arul Anandar College, Karumathur, Madurai-625 514 (India)

    2016-05-23

    Polyaniline (PANI) and its composites PANI-ZnO (Zinc oxide) and PANI-ZnO-GO (Graphene oxide) were successfully constructed. These materials were characterized by electron spin resonance (ESR) technique and ultraviolet visible spectrometry. The parameters such as line width, g-factor and spin concentration were deduced from ESR spectra, from the results the radical cation stabilization of PANI, PANI-ZnO and PANI-ZnO-GO composites were compared by the polaron and bipolaron formation. The absorption features obtained in the UV absorption spectra reveal the band gap of these modified PANI composites and also predicted the information of increasing and decreasing features of signal intensity and spin concentration.

  1. SOFIA tracking image simulation

    Science.gov (United States)

    Taylor, Charles R.; Gross, Michael A. K.

    2016-09-01

    The Stratospheric Observatory for Infrared Astronomy (SOFIA) tracking camera simulator is a component of the Telescope Assembly Simulator (TASim). TASim is a software simulation of the telescope optics, mounting, and control software. Currently in its fifth major version, TASim is relied upon for telescope operator training, mission planning and rehearsal, and mission control and science instrument software development and testing. TASim has recently been extended for hardware-in-the-loop operation in support of telescope and camera hardware development and control and tracking software improvements. All three SOFIA optical tracking cameras are simulated, including the Focal Plane Imager (FPI), which has recently been upgraded to the status of a science instrument that can be used on its own or in parallel with one of the seven infrared science instruments. The simulation includes tracking camera image simulation of starfields based on the UCAC4 catalog at real-time rates of 4-20 frames per second. For its role in training and planning, it is important for the tracker image simulation to provide images with a realistic appearance and response to changes in operating parameters. For its role in tracker software improvements, it is vital to have realistic signal and noise levels and precise star positions. The design of the software simulation for precise subpixel starfield rendering (including radial distortion), realistic point-spread function as a function of focus, tilt, and collimation, and streaking due to telescope motion will be described. The calibration of the simulation for light sensitivity, dark and bias signal, and noise will also be presented

  2. Tracking Information

    NARCIS (Netherlands)

    van Benthem, J.; Bimbó, K.

    2016-01-01

    Depending on a relevant task at hand, information can be represented at different levels, less or more detailed, each supporting its own appropriate logical languages. We discuss a few of these levels and their connections, and investigate when and how information growth at one level can be tracked

  3. Spectral Imaging Visualization and Tracking System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — To address the NASA Earth Observation Mission need for innovative optical tracking systems, Physical Optics Corporation (POC) proposes to develop a new Spectral...

  4. Electrical conductivity, optical properties and mechanical stability of 3, 4, 9, 10-perylenetetracarboxylic dianhidride based organic semiconductor

    Science.gov (United States)

    Pandey, Mayank; Joshi, Girish M.; Deshmukh, Kalim; Nath Ghosh, Narendra; Nambi Raj, N. Arunai

    2015-05-01

    The 3, 4, 9, 10-perylenetetracarboxylic dianhydride (PTCDA) doped polymer films were prepared with Polypyrrole (PPy) and Polyvinyl alcohol (PVA) polymers by solution-casting. The change in structure and chemical composition of samples was identified by XRD and FTIR respectively. The UV-visible spectroscopy demonstrates the optical characteristics and band gap properties of sample. The homogeneous morphology of sample for higher wt% of PTCDA was examined by atomic force microscopy (AFM). The differential scanning calorimetry (DSC) results demonstrate the decrease in melting temperature (Tm) and degree of crystallinity (χc%) of polymeric organic semiconductor. The mechanical property demonstrates the high tensile strength and improved plasticity nature. Impedance spectroscopy was evaluated to determine the conductivity response of polymeric organic semiconductor. The highest DC conductivity (2.08×10-3 S/m) was obtained for 10 wt% of PTCDA at 140 °C. The decrease in activation energy (Ea) represents the non-Debye process and was evaluated from the slope of ln σdc vs. 103/T plot.

  5. Fast-Track Teacher Recruitment.

    Science.gov (United States)

    Grant, Franklin Dean

    2001-01-01

    Schools need a Renaissance human-resources director to implement strategic staffing and fast-track teacher-recruitment plans. The HR director must attend to customer satisfaction, candidate supply, web-based recruitment possibilities, stabilization of newly hired staff, retention of veteran staff, utilization of retired employees, and latest…

  6. Tracking Porters

    DEFF Research Database (Denmark)

    Bruun, Maja Hojer; Krause-Jensen, Jakob; Saltofte, Margit

    2015-01-01

    Anthropology attempts to gain insight into people's experiential life-worlds through long-term fieldwork. The quality of anthropological knowledge production, however, does not depend solely on the duration of the stay in the field, but also on a particular way of seeing social situations. The an...... the students followed the work of a group of porters. Drawing on anthropological concepts and research strategies the students gained crucial insights about the potential effects of using tracking technologies in the hospital....

  7. Experiment definition phase shuttle laboratory LDRL-10.6 experiment. [applying optical communication

    Science.gov (United States)

    1975-01-01

    The 10.6 microns laser data relay link (LDRL 10.6) program was directed to applying optical communications to NASA's wideband data transmission requirements through the 1980's. The LDRL consists of a transmitter on one or more low earth orbit satellites with an elliptical orbit satellite receivers. Topics discussed include: update of the LDRL design control table to detail the transmitter optical chain losses and to incorporate the change to a reflective beam pre-expander; continued examination of the link establishment sequence, including its dependence upon spacecraft stability; design of the transmitter pointing and tracking control system; and finalization of the transmitter brassboard optical and mechanical design.

  8. An adaptive optics imaging system designed for clinical use

    Science.gov (United States)

    Zhang, Jie; Yang, Qiang; Saito, Kenichi; Nozato, Koji; Williams, David R.; Rossi, Ethan A.

    2015-01-01

    Here we demonstrate a new imaging system that addresses several major problems limiting the clinical utility of conventional adaptive optics scanning light ophthalmoscopy (AOSLO), including its small field of view (FOV), reliance on patient fixation for targeting imaging, and substantial post-processing time. We previously showed an efficient image based eye tracking method for real-time optical stabilization and image registration in AOSLO. However, in patients with poor fixation, eye motion causes the FOV to drift substantially, causing this approach to fail. We solve that problem here by tracking eye motion at multiple spatial scales simultaneously by optically and electronically integrating a wide FOV SLO (WFSLO) with an AOSLO. This multi-scale approach, implemented with fast tip/tilt mirrors, has a large stabilization range of ± 5.6°. Our method consists of three stages implemented in parallel: 1) coarse optical stabilization driven by a WFSLO image, 2) fine optical stabilization driven by an AOSLO image, and 3) sub-pixel digital registration of the AOSLO image. We evaluated system performance in normal eyes and diseased eyes with poor fixation. Residual image motion with incremental compensation after each stage was: 1) ~2–3 arc minutes, (arcmin) 2) ~0.5–0.8 arcmin and, 3) ~0.05–0.07 arcmin, for normal eyes. Performance in eyes with poor fixation was: 1) ~3–5 arcmin, 2) ~0.7–1.1 arcmin and 3) ~0.07–0.14 arcmin. We demonstrate that this system is capable of reducing image motion by a factor of ~400, on average. This new optical design provides additional benefits for clinical imaging, including a steering subsystem for AOSLO that can be guided by the WFSLO to target specific regions of interest such as retinal pathology and real-time averaging of registered images to eliminate image post-processing. PMID:26114033

  9. Stability limits for two-dimensional matter-wave solitons in a time-modulated quasi-one-dimensional optical lattice

    International Nuclear Information System (INIS)

    Mayteevarunyoo, Thawatchai; Malomed, Boris A.; Krairiksh, Monai

    2007-01-01

    In a basic physical model where two-dimensional (2D) matter-wave solitons may be stable, namely, the Gross-Pitaevskii equation with the self-attractive nonlinearity and quasi-one-dimensional (1D) optical-lattice (OL) potential, we test robustness of the solitons against periodic time modulation of the OL strength. Stability diagrams for the 2D solitons are presented in the plane of the modulation depth and frequency. Basic features of the diagrams are explained with the help of the variational approximation for the stationary counterpart of the model. In the Bose-Einstein condensate of 7 Li atoms, the stable 2D solitons may contain the number of atoms in the range of 10 4 -10 5 , relevant values of the OL strength and modulation frequency being, respectively < or approx. 5 recoil energies and < or approx. 10 kHZ. Head-on collisions between stable 2D solitons moving in the unconfined direction are studied in detail too, for velocities up to ∼5 cm/s. A border between quasi-elastic collisions and merger of the solitons into a single localized state is identified. In some cases, the soliton produced by the merger is stable against collapse, which was not observed before in the static OL potential either

  10. Enhanced Stability of Gold Magnetic Nanoparticles with Poly(4-styrenesulfonic acid-co-maleic acid): Tailored Optical Properties for Protein Detection

    Science.gov (United States)

    Zhang, Xiaomei; Zhang, Qinlu; Ma, Ting; Liu, Qian; Wu, Songdi; Hua, Kai; Zhang, Chao; Chen, Mingwei; Cui, Yali

    2017-09-01

    Gold magnetic nanoparticles (GoldMag) have attracted great attention due to their unique physical and chemical performances combining those of individual Fe3O4 and Au nanoparticles. Coating GoldMag with polymers not only increases the stability of the composite particles suspended in buffer but also plays a key role for establishing point-of-care optical tests for clinically relevant biomolecules. In the present paper, poly(4-styrenesulfonic acid-co-maleic acid) (PSS-MA), a negatively charged polyelectrolyte with both sulfonate and carboxylate anionic groups, was used to coat the positively charged GoldMag (30 nm) surface. The PSS-MA-coated GoldMag complex has a stable plasmon resonance adsorption peak at 544 nm. A pair of anti-D-dimer antibodies has been coupled on this GoldMag composite nanoparticle surface, and a target protein, D-dimer was detected, in the range of 0.3-6 μg/mL. The shift of the characteristic peak, caused by the assembly of GoldMag due to the formation of D-dimer-antibody sandwich bridges, allowed the detection.

  11. Preparation and thermo-optical characteristics of a smart polymer-stabilized liquid crystal thin film based on smectic A–chiral nematic phase transition

    International Nuclear Information System (INIS)

    Sun, Jian; Wang, Huihui; Cao, Hui; Ding, Hangjun; Yang, Zhou; Yang, Huai; Wang, Ling; Xie, Hui; Luo, Xueyao; Xiao, Jiumei

    2014-01-01

    A smart polymer stabilized liquid crystal (PSLC) thin film with temperature-controllable light transmittance was prepared based on a smectic-A (SmA)–chiral nematic (N*) phase transition, and then the effect of the composition and the preparation condition of the PSLC film on its thermo-optical (T-O) characteristics has been investigated in detail. Within the temperature range of the SmA phase, the PSLC shows a strong opaque state due to the focal conic alignment of liquid crystal (LC) molecules, while the film exhibits a transparent state result from the parallel alignment of N* phase LC molecules at a higher temperature. Importantly, the PSLC films with different temperature of phase transition and contrast ratio can be prepared by changing the composition of photo-polymerizable monomer/LC/chiral dopant. According to the competition between the polymerization of the curable monomers and the diffusion of LC molecules, the ultraviolet (UV) curing surrounding temperature and the intensity of UV irradiation play a critical role in tuning the size of the polymer network meshes, which in turn influence the contrast ratio and the switching speed of the film. Our observations are expected to pave the way for preparing smart PSLC thin films for applications in areas of smart windows, thermo-detectors and other information recording devices. (paper)

  12. Improved structure stability, optical and magnetic properties of Ca and Ti co-substituted BiFeO{sub 3} nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Vijay; Singh, Satyendra, E-mail: satyambd@gmail.com

    2016-11-15

    Graphical abstract: (a) UV–vis absorption spectra and (b) Tauc’s plots to determine the band gap of the Bi{sub 1-x}Ca{sub x}Fe{sub 1-x}Ti{sub x}O{sub 3} nanoparticles for x = 0 (S1), 0.05 (S2), 0.10 (S3), 0.15 (S4), 0.20 (S5) and 0.25 (S6), respectively (c) Variation of band gap with x for Bi{sub 1-x}Ca{sub x}Fe{sub 1-x}Ti{sub x}O{sub 3} nanoparticles. Display Omitted - Highlights: • First report on synthesis of Bi{sub 1-x}Ca{sub x}Fe{sub 1-x}Ti{sub x}O{sub 3}, nanoparticles (0 ≤ x ≤ 0.25). • Ca and Ti co-substitutions control the formation of secondary phases and improved the stability of perovskite phase. • Strong absorption of visible light with a small optical band gap (1.77–2.26 eV). • Improved M{sub r} and H{sub c} due to the release of the latent magnetization locked within the toroidal spin structure. • May be useful for data storage, spintronics and optoelectronics. - Abstract: We report the optical and magnetic properties of single-crystalline Ca and Ti co-substituted bismuth ferrite, Bi{sub 1-x}Ca{sub x}Fe{sub 1-x}Ti{sub x}O{sub 3}, nanoparticles, synthesized by a facile sol–gel methodology in the compositional range wherein 0 ≤ x ≤ 0.25. X-ray diffraction (XRD) and transmission electron microscopy (TEM) investigations show that all samples possess a rhombohedrally distorted perovskite structure with space group R3c. Ca and Ti co-substitution controls the formation of secondary phases and improved the stability of perovskite phase of BiFeO{sub 3}. The average particle size was estimated by Williamson Hall plot, confirmed by TEM, and found to be about 59, 50, 46, 41, 40 and 38 nm of Bi{sub 1-x}Ca{sub x}Fe{sub 1-x}Ti{sub x}O{sub 3} for x = 0, 0.05, 0.10, 0.15, 0.20 and 0.25, respectively. The UV–vis absorption study reveal the strong absorption of visible light with a small optical band gap (1.77–2.25 eV) for 0 ≤ x ≤ 0.25 indicates a possibility of utilizing for photocatalytic activities. The magnetic study at room

  13. Stabilization and trajectory tracking control for underactuated ...

    Indian Academy of Sciences (India)

    The control law design utilizes the switching function in order to attenuate the effects caused by external disturbances. In order to eliminate the chattering phenomenon, the sign function is replaced by the saturation function. A new heuristic algorithm namely Gravitational Search Algorithm (GSA) has been employed in ...

  14. Stabilization and trajectory tracking control for underactuated ...

    Indian Academy of Sciences (India)

    , Nemati H and Smailzadeh S 2013 Attitude control of a Quadrotor with optimized PID controller. Intelligent Control Autom. 4: 335–342. Boškovic D M and Krstic M 2002 Backstepping control of chemical tubular reactors. Comp.Chem. Eng.

  15. Stabilization and trajectory tracking control for underactuated ...

    Indian Academy of Sciences (India)

    on a quadrotor simulation environment to demonstrate the effectiveness and merits of the theoretical development. Simulation results show that the ...... Bolandi H, Rezaei M, Mohsenipour R, Nemati H and Smailzadeh S 2013 Attitude control of a Quadrotor with optimized PID controller. Intelligent Control Autom. 4: 335–342.

  16. Stability of Streamer Chamber

    Science.gov (United States)

    Wada, Toshiaki; Ogawa, Masato; Takahashi, Kaoru; Sugiyama, Tsunetoshi; Kobayashi, Shigeharu; Kohno, Hirobumi

    1982-08-01

    The quality of tracks obtained from a streamer chamber is studied through the measurement of the streamer brightness. The stability of streamer tracks depends on the value of the high voltage applied and its shape. By using a single conical-type spark gap as the pulse shaper, stable brightness of the streamer tracks is attained. The data on the streamer brightness are compared with the result by Bulos et al. and it is found that the brightness is more strongly affected by field parameters than in their result.

  17. Stability of streamer chamber

    International Nuclear Information System (INIS)

    Wada, Toshiaki; Ogawa, Masato; Takahashi, Kaoru; Sugiyama, Tsunetoshi; Kobayashi, Shigeharu; Kohno, Hirobumi.

    1982-01-01

    The quality of tracks obtained from a streamer chamber is studied through the measurement of the streamer brightness. The stability of streamer tracks depends on the value of the high voltage applied and its shape. By using a single conical-type spark gap as the pulse shaper, stable brightness of the streamer tracks is attained. The data on the streamer brightness are compared with the result by Bulos et al. and it is found that the brightness is more strongly affected by field parameters than in their result. (author)

  18. INNER TRACKING

    CERN Multimedia

    P. Sharp

    The CMS Inner Tracking Detector continues to make good progress. The Objective for 2006 was to complete all of the CMS Tracker sub-detectors and to start the integration of the sub-detectors into the Tracker Support Tube (TST). The Objective for 2007 is to deliver to CMS a completed, installed, commissioned and calibrated Tracking System (Silicon Strip and Pixels) aligned to < 100µ in April 2008 ready for the first physics collisions at LHC. In November 2006 all of the sub-detectors had been delivered to the Tracker Integration facility (TIF) at CERN and the tests and QA procedures to be carried out on each sub-detector before integration had been established. In December 2006, TIB/TID+ was integrated into TOB+, TIB/TID- was being prepared for integration, and TEC+ was undergoing tests at the final tracker operating temperature (-100 C) in the Lyon cold room. In February 2007, TIB/TID- has been integrated into TOB-, and the installation of the pixel support tube and the services for TI...

  19. Fibre tracking

    International Nuclear Information System (INIS)

    Gaillard, J.M.

    1994-03-01

    A large-size scintillating plastic fibre tracking detector was built as part of the upgrade of the UA2 central detector at the SPS proton-antiproton collider. The cylindrical fibre detector of average radius of 40 cm consisted of 60000 plastic fibres with an active length of 2.1 m. One of the main motivations was to improve the electron identification. The fibre ends were bunched to be coupled to read-out systems of image intensifier plus CCD, 32 in total. The quality and the reliability of the UA2 fibre detector performance exceeded expectations throughout its years of operation. A few examples of the use of image intensifiers and of scintillating fibres in biological instrumentation are described. (R.P.) 11 refs., 15 figs., 2 tabs

  20. Fuzzy Logic Particle Tracking

    Science.gov (United States)

    2005-01-01

    A new all-electronic Particle Image Velocimetry technique that can efficiently map high speed gas flows has been developed in-house at the NASA Lewis Research Center. Particle Image Velocimetry is an optical technique for measuring the instantaneous two component velocity field across a planar region of a seeded flow field. A pulsed laser light sheet is used to illuminate the seed particles entrained in the flow field at two instances in time. One or more charged coupled device (CCD) cameras can be used to record the instantaneous positions of particles. Using the time between light sheet pulses and determining either the individual particle displacements or the average displacement of particles over a small subregion of the recorded image enables the calculation of the fluid velocity. Fuzzy logic minimizes the required operator intervention in identifying particles and computing velocity. Using two cameras that have the same view of the illumination plane yields two single exposure image frames. Two competing techniques that yield unambiguous velocity vector direction information have been widely used for reducing the single-exposure, multiple image frame data: (1) cross-correlation and (2) particle tracking. Correlation techniques yield averaged velocity estimates over subregions of the flow, whereas particle tracking techniques give individual particle velocity estimates. For the correlation technique, the correlation peak corresponding to the average displacement of particles across the subregion must be identified. Noise on the images and particle dropout result in misidentification of the true correlation peak. The subsequent velocity vector maps contain spurious vectors where the displacement peaks have been improperly identified. Typically these spurious vectors are replaced by a weighted average of the neighboring vectors, thereby decreasing the independence of the measurements. In this work, fuzzy logic techniques are used to determine the true

  1. A gimbal platform stabilization for topographic applications

    Energy Technology Data Exchange (ETDEWEB)

    Michele, Mangiameli, E-mail: michele.mangiameli@dica.unict.it; Giuseppe, Mussumeci [Dept. of Civil Engineering and Architecture, University of Catania, Catania (Italy)

    2015-03-10

    The aim of this work is the stabilization of a Gimbal platform for optical sensors acquisitions in topographic applications using mobile vehicles. The stabilization of the line of sight (LOS) consists in tracking the command velocity in presence of nonlinear noise due to the external environment. The hardware architecture is characterized by an Ardupilot platform that allows the control of both the mobile device and the Gimbal. Here we developed a new approach to stabilize the Gimbal platform, which is based on neural network. For the control system, we considered a plant that represents the transfer function of the servo system control model for an inertial stabilized Gimbal platform. The transductor used in the feed-back line control is characterized by the Rate Gyro transfer function installed onboard of Ardupilot. For the simulation and investigation of the system performance, we used the Simulink tool of Matlab. Results show that the hardware/software approach is efficient, reliable and cheap for direct photogrammetry, as well as for general purpose applications using mobile vehicles.

  2. Random Vibration Analysis of Train Moving over Slab Track on Bridge under Track Irregularities and Earthquakes by Pseudoexcitation Method

    OpenAIRE

    Zeng, Zhiping; Zhu, Kunteng; He, Xianfeng; Xu, Wentao; Chen, Lingkun; Lou, Ping

    2015-01-01

    This paper investigates the random vibration and the dynamic reliability of operation stability of train moving over slab track on bridge under track irregularities and earthquakes by the pseudoexcitation method (PEM). Each vehicle is modeled by multibody dynamics. The track and bridge is simulated by a rail-slab-girder-pier interaction finite element model. The coupling equations of motion are established based on the wheel-rail interaction relationship. The random excitations of the track i...

  3. Semantic Audio Track Mixer

    OpenAIRE

    Uhle, C.; Herre, J.; Ridderbusch, F.; Popp, H.

    2011-01-01

    An audio mixer for mixing a plurality of audio tracks to a mixture signal comprises a semantic command interpreter (30; 35) for receiving a semantic mixing command and for deriving a plurality of mixing parameters for the plurality of audio tracks from the semantic mixing command; an audio track processor (70; 75) for processing the plurality of audio tracks in accordance with the plurality of mixing parameters; and an audio track combiner (76) for combining the plurality of audio tracks proc...

  4. INNER TRACKING

    CERN Multimedia

    Peter Sharp

    The Silicon Strip Tracker was successfully installed into CMS on December 15, and was subsequently aligned to the LHC beam line to +/- 1mm. Before the Tracker was installed all of the connections from the low voltage power supplies, the cooling plants and optical readout fibres from the ‘off detector’ electronics had been installed to Patch Panel 1 (PP1), on the CMS magnet cryostat, and thoroughly tested. The careful connection of the Tracker to PP1 started in early January and will be completed in early March, just before the central section of the LHC beam pipe is installed into CMS. After initial checks of all the safety interlocks and the cooling circuits, the quality of each of the connections will be verified by commissioning each section of the Tracker in turn and reading back the calibration pulses (tick marks) from the front-end electronics. This process verifies that all of the connections are correct and in particular, that the quality of the fibre connections is good. When ...

  5. Acquisition, tracking, and pointing V; Proceedings of the Meeting, Orlando, FL, Apr. 3-5, 1991

    Science.gov (United States)

    Masten, Michael K.; Stockum, Larry A.

    1991-08-01

    The present conference discusses the Starlab control system, an angular positioning mechanism for a UV coronagraph spectrometer, a second-generation laser tracking system, the optimization of a gimbal-scanned IR seeker, design considerations for an airborne electrooptic sensor, the effects of atmospheric turbulence on a relay mirror experiment, and the sensor fusion approach to optimization for human perception. Also discussed are target detection with a co-occurrence matrix segmentation, imaging autotracker technology for guided missile systems, a fuzzy logic approach to multitarget tracking in clutter, salient contour extraction for target recognition, accelerometer-based platform stabilization, a low-drift fiber-optic gyro for earth-rate applications, and velocity profiling in linear and rotational systems. (No individual items are abstracted in this volume)

  6. Optics/Optical Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Optics/Optical Diagnostics Laboratory supports graduate instruction in optics, optical and laser diagnostics and electro-optics. The optics laboratory provides...

  7. Compact optical transmitters for CubeSat free-space optical communications

    Science.gov (United States)

    Kingsbury, R. W.; Caplan, D. O.; Cahoy, K. L.

    2015-03-01

    We present the results of an architectural trade study and prototype implementation of an optical transmitter suitable for resource-constrained CubeSats. Recent advances in CubeSat attitude determination and control systems have made it possible to achieve three-axis stabilization. This is essential for laser communications systems, which have challenging pointing and stability requirements. Our downlink terminal design fits in a 10 cm x 10 cm x 5 cm volume, uses < 10W of power, weighs < 1 kg, and supports data rates up to 50 Mbps. The terminal incorporates pointing, tracking and acquisition optics, an optical fine-steering mechanism, and a compact transmitter. This work focuses on the development of the transmitter for the Nanosatellite Optical Downlink Experiment (NODE). Two transmitter architectures were considered initially: direct modulation of a high-power laser diode and a master oscillator power amplifier (MOPA). The MOPA-based approach was selected and a prototype "breadboard" was built from commercially available components. The prototype transmitter produces high fidelity (extinction ratio, ER < 33 dB) pulse position modulation (PPM) waveforms at 1550nm with 200mW average output power while consuming 6:5W of electrical power.

  8. Tracking Eyes using Shape and Appearance

    DEFF Research Database (Denmark)

    Hansen, Dan Witzner; Nielsen, Mads; Hansen, John Paulin

    2002-01-01

    multi-modal interactions based on video tracking systems. Robust methods are needed to track the eyes using web cameras due to the poor image quality. A real-time tracking scheme using a mean-shift color tracker and an Active Appearance Model of the eye is proposed. From this model, it is possible......We propose a non-intrusive eye tracking system intended for the use of everyday gaze typing using web cameras. We argue that high precision in gaze tracking is not needed for on-screen typing due to natural language redundancy. This facilitates the use of low-cost video components for advanced...... to infer the state of the eye such as eye corners and the pupil location under scale and rotational changes. We use a Gaussian Process interpolation method for gaze determination, which facilitates stability feedback from the system. The use of a learning method for gaze estimation gives more flexibility...

  9. Stability Landscape of Shell Buckling

    Science.gov (United States)

    Virot, Emmanuel; Kreilos, Tobias; Schneider, Tobias M.; Rubinstein, Shmuel M.

    2017-12-01

    We measure the response of cylindrical shells to poking and identify a stability landscape, which fully characterizes the stability of perfect shells and imperfect ones in the case where a single defect dominates. We show that the landscape of stability is independent of the loading protocol and the poker geometry. Our results suggest that the complex stability of shells reduces to a low dimensional description. Tracking ridges and valleys of this landscape defines a natural phase-space coordinates for describing the stability of shells.

  10. Solar tracking system

    Science.gov (United States)

    Okandan, Murat; Nielson, Gregory N.

    2016-07-12

    Solar tracking systems, as well as methods of using such solar tracking systems, are disclosed. More particularly, embodiments of the solar tracking systems include lateral supports horizontally positioned between uprights to support photovoltaic modules. The lateral supports may be raised and lowered along the uprights or translated to cause the photovoltaic modules to track the moving sun.

  11. Scalable Track Initiation for Optical Space Surveillance

    Science.gov (United States)

    2012-09-01

    orbital elements. Descartes ’ rule of signs tells us the number of positive real roots. If the third coefficient in the quadratic form (3) is...specified intervals of the orbital elements. Assuming that we have real roots in equation (8), we use Descartes ’ rule of signs to determine the number

  12. System and method for determining stability of a neural system

    Science.gov (United States)

    Curtis, Steven A. (Inventor)

    2011-01-01

    Disclosed are methods, systems, and computer-readable media for determining stability of a neural system. The method includes tracking a function world line of an N element neural system within at least one behavioral space, determining whether the tracking function world line is approaching a psychological stability surface, and implementing a quantitative solution that corrects instability if the tracked function world line is approaching the psychological stability surface.

  13. Automatic neutron dosimetry system based on fluorescent nuclear track detector technology

    International Nuclear Information System (INIS)

    Akselrod, M.S.; Fomenko, V.V.; Bartz, J.A.; Haslett, T.L.

    2014-01-01

    For the first time, the authors are describing an automatic fluorescent nuclear track detector (FNTD) reader for neutron dosimetry. FNTD is a luminescent integrating type of detector made of aluminium oxide crystals that does not require electronics or batteries during irradiation. Non-destructive optical readout of the detector is performed using a confocal laser scanning fluorescence imaging with near-diffraction limited resolution. The fully automatic table-top reader allows one to load up to 216 detectors on a tray, read their engraved IDs using a CCD camera and optical character recognition, scan and process simultaneously two types of images in fluorescent and reflected laser light contrast to eliminate false-positive tracks related to surface and volume crystal imperfections. The FNTD dosimetry system allows one to measure neutron doses from 0.1 mSv to 20 Sv and covers neutron energies from thermal to 20 MeV. The reader is characterised by a robust, compact optical design, fast data processing electronics and user-friendly software. The first table-top automatic FNTD neutron dosimetry system was successfully tested for LLD, linearity and ability to measure neutrons in mixed neutron-photon fields satisfying US and ISO standards. This new neutron dosimetry system provides advantages over other technologies including environmental stability of the detector material, wide range of detectable neutron energies and doses, detector re-readability and re-usability and all-optical readout. A new adaptive image processing algorithm reliably removes false-positive tracks associated with surface and bulk crystal imperfections. (authors)

  14. Rotational symmetric HMD with eye-tracking capability

    Science.gov (United States)

    Liu, Fangfang; Cheng, Dewen; Wang, Qiwei; Wang, Yongtian

    2016-10-01

    As an important auxiliary function of head-mounted displays (HMDs), eye tracking has an important role in the field of intelligent human-machine interaction. In this paper, an eye-tracking HMD system (ET-HMD) is designed based on the rotational symmetric system. The tracking principle in this paper is based on pupil-corneal reflection. The ET-HMD system comprises three optical paths for virtual display, infrared illumination, and eye tracking. The display optics is shared by three optical paths and consists of four spherical lenses. For the eye-tracking path, an extra imaging lens is added to match the image sensor and achieve eye tracking. The display optics provides users a 40° diagonal FOV with a ״ 0.61 OLED, the 19 mm eye clearance, and 10 mm exit pupil diameter. The eye-tracking path can capture 15 mm × 15 mm of the users' eyes. The average MTF is above 0.1 at 26 lp/mm for the display path, and exceeds 0.2 at 46 lp/mm for the eye-tracking path. Eye illumination is simulated using LightTools with an eye model and an 850 nm near-infrared LED (NIR-LED). The results of the simulation show that the illumination of the NIR-LED can cover the area of the eye model with the display optics that is sufficient for eye tracking. The integrated optical system HMDs with eye-tracking feature can help improve the HMD experience of users.

  15. Beam instabilities in race track microtrons

    International Nuclear Information System (INIS)

    Euteneuer, H.; Herminghaus, H.; Klein, R.

    1982-01-01

    Several limitations of the benefits of the race track microtron (RTM) as an economic cw electron accelerator are discussed. For beam blowup some final results of our investigations for the Mainz Microtron are given. The other two effects presented more generally are beam diffusion by imperfections of the optical elements of a RTM and the deterioration of transverse phase space by synchrotron radiation

  16. An Assessment of a Low-Cost Visual Tracking System (VTS) to Detect and Compensate for Patient Motion During SPECT

    Science.gov (United States)

    McNamara, Joseph E.; Bruyant, Philippe; Johnson, Karen; Feng, Bing; Lehovich, Andre; Gu, Songxiang; Gennert, Michael A.; King, Michael A.

    2008-06-01

    Patient motion is inevitable in SPECT and PET due to the lengthy period of time patients are imaged and patient motion can degrade diagnostic accuracy. The goal of our studies is to perfect a methodology for tracking and correcting patient motion when it occurs. In this paper we report on enhancements to the calibration, camera stability, accuracy of motion tracking, and temporal synchronization of a low-cost visual tracking system (VTS) we are developing. The purpose of the VTS is to track the motion of retro-reflective markers on stretchy bands wrapped about the chest and abdomen of patients. We have improved the accuracy of 3D spatial calibration by using a MATLAB optical camera calibration package with a planar calibration pattern. This allowed us to determine the intrinsic and extrinsic parameters for stereo-imaging with our CCD cameras. Locations in the VTS coordinate system are transformed to the SPECT coordinate system by a VTS/SPECT mapping using a phantom of 7 retro-reflective spheres each filled with a drop of Tc99m. We switched from pan, tilt and zoom (PTZ) network cameras to fixed network cameras to reduce the amount of camera drift. The improved stability was verified by tracking the positions of fixed retro-reflective markers on a wall. The ability of our VTS to track movement, on average, with sub-millimeter and sub-degree accuracy was established with the 7-sphere phantom for 1 cm vertical and axial steps as well as for an arbitrary rotation and translation. The difference in the time of optical image acquisition as decoded from the image headers relative to synchronization signals sent to the SPECT system was used to establish temporal synchrony between optical and list-mode SPECT acquisition. Two experiments showed better than 100 ms agreement between VTS and SPECT observed motion for three axial translations. We were able to track 3 reflective markers on an anthropomorphic phantom with a precision that allowed us to correct motion such that no

  17. Adaptive DFT-based Interferometer Fringe Tracking

    Science.gov (United States)

    Wilson, Edward; Pedretti, Ettore; Bregman, Jesse; Mah, Robert W.; Traub, Wesley A.

    2004-01-01

    An automatic interferometer fringe tracking system has been developed, implemented, and tested at the Infrared Optical Telescope Array (IOTA) observatory at Mt. Hopkins, Arizona. The system can minimize the optical path differences (OPDs) for all three baselines of the Michelson stellar interferometer at IOTA. Based on sliding window discrete Fourier transform (DFT) calculations that were optimized for computational efficiency and robustness to atmospheric disturbances, the algorithm has also been tested extensively on off-line data. Implemented in ANSI C on the 266 MHz PowerPC processor running the VxWorks real-time operating system, the algorithm runs in approximately 2.0 milliseconds per scan (including all three interferograms), using the science camera and piezo scanners to measure and correct the OPDs. The adaptive DFT-based tracking algorithm should be applicable to other systems where there is a need to detect or track a signal with an approximately constant-frequency carrier pulse.

  18. Particularization of alpha contamination using CR-39 track detectors

    Indian Academy of Sciences (India)

    each was sandwiched to be dried in desiccant paper. To obtain the track diameter distribution and track density, the etched detec- tors were read and measured using an automatic digital image analysis system. (LEICA), consisting of a DMRE optical microscope with 600× magnification, a. Pramana – J. Phys., Vol. 69, No.

  19. Head Tracking via Robust Registration in Texture Map Images

    National Research Council Canada - National Science Library

    LaCascia, Marco

    1998-01-01

    .... The resulting dynamic texture map provides a stabilized view of the face that can be used as input to many existing 2D techniques for face recognition, facial expressions analysis, lip reading, and eye tracking...

  20. Double Tracks revegetation and monitoring plan

    International Nuclear Information System (INIS)

    1997-07-01

    This document is a reclamation plan for short-term and long-term stabilization of land disturbed by activities associated with interim clean-up of radionuclide-contaminated surface soil at the Double Tracks site. This document has been prepared to provide general reclamation practices and procedures that will be followed during restoration of the cleanup site. Reclamation demonstration plots were established near the site in the fall of 1994 to evaluate the performance of several native species and to evaluate different irrigation strategies. Results of the study at Double Tracks, as well as the results from numerous studies conducted at other sites (Area 11 and Area 19 of the Nevada Test Site), have been summarized and incorporated into this final reclamation plan for the interim cleanup of the Double Tracks site, located northwest of the Nevada Test Site on the Nellis Air Force Range. Surface soils at Double Tracks were contaminated as a result of the detonation of a device containing plutonium and depleted uranium using chemical explosives. The total amount of Pu deposited on the site was between 980 and 1,600 grams and was scattered downwind south of the detonation site. Short-term stabilization consists of the application of a chemical soil stabilizer that is applied immediately following excavation of the contaminated soils to minimize Pu resuspension. Long-term stabilization is accomplished by the establishment of a permanent vegetation

  1. "Proof of concept" pilot study: bioprocess chain of custody and bioresource sample management temperature observations. Sample level temperature trends and stability data obtained via utilization of bluechiip(®) temperature tracking technology.

    Science.gov (United States)

    Miranda, Lisa B; Wyatt, Kathleen; Johnston, Ian; Milljanic, Miroslav; Chaffey, Jason

    2013-04-01

    Preservation and optimization of biosample integrity to foster relevant research results and outcomes is a guiding principle of sample management. Tracking pre-analytical biospecimen lifecycle variables and bioprocessing chain of custody data enables documentation of adherence to best, regulatory and quality biobanking practices. Knowledge of individual sample and sample set temperature variability is believed to enhance delineation of artifacts during downstream analysis. Analysis of temperature responses may elucidate understanding of temperature trends which can aid downstream interpretation and provide an empirical foundation for "fit for purpose" sample management protocols and evidence-based biobanking practices. Bluechiip and the American Type Culture Collection (ATCC) conducted a pilot to test the bluechiip technology(®) performance and validate key proofs of concept for tracking temperature of biological samples. One hundred six (106) Corning(®) cryovials with bluechiip(®) buttons and one hundred six (106) standard Corning(®) cryovials labeled with 1-dimensional (1D) barcoded labels were evaluated. Identifiers were tracked and temperature data recorded in corresponding environments ranging from -192°C to +57°. Nine of ten proof of concepts, defined in collaboration with ATCC successfully demonstrated functional capabilities of the bluechiip(®) technology. Bar-code label read performance was compared, producing evidence demonstrating a high rate of failure on the bar-code arm. Temperature data collected heightened observations of sample temperature variability. Prevalence of bar-code label read failure and issues affecting reliability of barcode performance may be under-reported and unrecognized in sample management practice, particularly when the temperatures are lower than -60°C. It appears the bluechiip(®) tracking technology may offer increased reliability over one-dimensional (1D) bar-coding technology; however while promising these findings

  2. Renewable Energy Tracking Systems

    Science.gov (United States)

    Renewable energy generation ownership can be accounted through tracking systems. Tracking systems are highly automated, contain specific information about each MWh, and are accessible over the internet to market participants.

  3. Forward tracking detectors

    Indian Academy of Sciences (India)

    Abstract. Forward tracking is an essential part of a detector at the international linear collider (ILC). The requirements for forward tracking are explained and the proposed solutions in the detector concepts are shown.

  4. Eye Tracking for Everyone

    OpenAIRE

    Kellnhofer, Petr; Bhandarkar, Suchendra; Khosla, Aditya; Kannan, Harini D.; Matusik, Wojciech; Torralba, Antonio

    2016-01-01

    From scientific research to commercial applications, eye tracking is an important tool across many domains. Despite its range of applications, eye tracking has yet to become a pervasive technology. We believe that we can put the power of eye tracking in everyone's palm by building eye tracking software that works on commodity hardware such as mobile phones and tablets, without the need for additional sensors or devices. We tackle this problem by introducing GazeCapture, the first large-scale ...

  5. HLT Track Reconstruction Performance

    CERN Document Server

    The ATLAS Collaboration

    2009-01-01

    This note reviews the tracking algorithms used at the L2 and Event Filter stages of the High Level Trigger of ATLAS. The tracking performance (efficiency, resolution) is studied for different topologies (single tracks, high and low pt jets) using simulated data. Detailed information on the execution time of the algorithms is also given.

  6. Performance of ATLAS tracking

    CERN Document Server

    Roe, Shaun; The ATLAS collaboration

    2017-01-01

    Run-2 of the Large Hadron Collider (LHC) has provided new challenges to track and vertex reconstruction with higher centre-of-mass energies and luminosity leading to increasingly high-multiplicity envi-ronments. This talk provides an overview of the tracking performance, highlighting tracking improvements due to the Insertable B-Layer (IBL) and the introduction of time-dependent alignment.

  7. Cationic oligopeptides with the repeating sequence L-Lysyl-L-alanyl-L-alanine: conformational and thermal stability stuydy using optical spectroscopic methods

    Czech Academy of Sciences Publication Activity Database

    Setnička, V.; Hlaváček, Jan; Urbanová, J.

    2009-01-01

    Roč. 15, č. 8 (2009), s. 533-539 ISSN 1075-2617 Institutional research plan: CEZ:AV0Z40550506 Keywords : cationic peptides * conformation * thermal stability * vibrational circular dichroism Subject RIV: CC - Organic Chemistry Impact factor: 1.807, year: 2009

  8. Persistent Aerial Tracking system for UAVs

    KAUST Repository

    Mueller, Matthias

    2016-12-19

    In this paper, we propose a persistent, robust and autonomous object tracking system for unmanned aerial vehicles (UAVs) called Persistent Aerial Tracking (PAT). A computer vision and control strategy is applied to a diverse set of moving objects (e.g. humans, animals, cars, boats, etc.) integrating multiple UAVs with a stabilized RGB camera. A novel strategy is employed to successfully track objects over a long period, by ‘handing over the camera’ from one UAV to another. We evaluate several state-of-the-art trackers on the VIVID aerial video dataset and additional sequences that are specifically tailored to low altitude UAV target tracking. Based on the evaluation, we select the leading tracker and improve upon it by optimizing for both speed and performance, integrate the complete system into an off-the-shelf UAV, and obtain promising results showing the robustness of our solution in real-world aerial scenarios.

  9. Development of uranium standard glass for fission tracks technology calibration

    International Nuclear Information System (INIS)

    Zhao Yunlong; Wu Zhaohui; Huang Qiuhong; Wang Bing; Zhai Pengji

    1997-07-01

    The uranium standard glass is developed to meet the need of application of fission tracks technology. It's main composition are SiO 2 , Na 2 O, CaO, Al 2 O 3 , etc. Tests indicate that uranium in the glass is well-distributed; the content (mass fraction) of element B is smaller than 3 μg/g, Cd smaller than 2.1 μg/g, and Th smaller than 0.3 μg/g. The acid-resisting property reaches the level of the first class optical glass; and the moist-resisting property reaches the level of the second class optical glass. The contents of uranium in UB1 and UB2 uranium glass determined by several laboratories are (1.89 +- 0.05) μg/g and (11.2 +- 0.2) μg/g respectively; the stability test after a year indicates that its properties are stable. (11 tabs., 1 figs.)

  10. Co-sputtering deposition of Cu doped SnS thin films for photovoltaic application: Phase stability, microstructure and optical properties

    Science.gov (United States)

    Baby, Benjamin Hudson; Mohan, D. Bharathi

    2017-06-01

    Cu doped SnS films were successfully fabricated using co-sputtering technique for the first time with the substrate temperature of 400 °C. Cu doping percentage is controlled by varying the dc sputtering voltage from 225V to 325V. The phase formation, surface morphology and optical properties of Cu doped SnS films were studied using X-ray diffraction, confocal Raman spectrometer, atomic force microscope and UV-Vis-NIR spectrophotometer. Structural analysis confirmed the formation of Cu doped SnS films for low dc sputtering voltage while by increasing the sputtering voltage to 325V leads to the semiconductor to metallic transition of the films as evident from optical properties.

  11. Tracking by Neural Nets

    CERN Document Server

    Jofrehei, Arash

    2015-01-01

    Current track reconstruction methods start with two points and then for each layer loop through all possible hits to find proper hits to add to that track. Another idea would be to use this large number of already reconstructed events and/or simulated data and train a machine on this data to find tracks given hit pixels. Training time could be long but real time tracking is really fast. Simulation might not be as realistic as real data but tracking efficiency is 100 percent for that while by using real data we would probably be limited to current efficiency. The fact that this approach can be a lot faster and even more efficient than current methods by using simulation data can make it a great alternative for current track reconstruction methods used in both triggering and tracking.

  12. Advanced Tracking of Vehicles

    DEFF Research Database (Denmark)

    Jensen, Christian Søndergaard; Li, K.-J.; Pakalnis, Stardas

    2005-01-01

    With the continued advances in wireless communications, geo-location technologies, and consumer electronics, it is becoming possible to accurately track the time-varying location of each vehicle in a population of vehicles. This paper reports on ongoing research that has as it objective to develop...... efficient tracking techniques. More specifically, while almost all commercially available tracking solutions simply offer time-based sampling of positions, this paper's techniques aim to offer a guaranteed tracking accuracy for each vehicle at the lowest possible costs, in terms of network traffic...... and server-side updates. This is achieved by designing, prototyping, and testing novel tracking techniques that exploit knowledge of the road network and past movement. These resulting tracking techniques are to support mobile services that rely on the existence of a central server that continuously tracks...

  13. Tracks: Nurses and the Tracking Network

    Centers for Disease Control (CDC) Podcasts

    2012-06-06

    This podcast highlights the utility of the National Environmental Public Health Tracking Network for nurses in a variety of work settings. It features commentary from the American Nurses Association and includes stories from a public health nurse in Massachusetts.  Created: 6/6/2012 by National Center for Environmental Health (NCEH)/Division of Environmental Hazards and Health Effects (DEHHE)/Environmental Health Tracking Branch (EHTB).   Date Released: 6/6/2012.

  14. Medical Imaging for the Tracking of Micromotors.

    Science.gov (United States)

    Vilela, Diana; Cossío, Unai; Parmar, Jemish; Martínez-Villacorta, Angel M; Gómez-Vallejo, Vanessa; Llop, Jordi; Sánchez, Samuel

    2018-02-27

    Micro/nanomotors are useful tools for several biomedical applications, including targeted drug delivery and minimally invasive microsurgeries. However, major challenges such as in vivo imaging need to be addressed before they can be safely applied on a living body. Here, we show that positron emission tomography (PET), a molecular imaging technique widely used in medical imaging, can also be used to track a large population of tubular Au/PEDOT/Pt micromotors. Chemisorption of an iodine isotope onto the micromotor's Au surface rendered them detectable by PET, and we could track their movements in a tubular phantom over time frames of up to 15 min. In a second set of experiments, micromotors and the bubbles released during self-propulsion were optically tracked by video imaging and bright-field microscopy. The results from direct optical tracking agreed with those from PET tracking, demonstrating that PET is a suitable technique for the imaging of large populations of active micromotors in opaque environments, thus opening opportunities for the use of this mature imaging technology for the in vivo localization of artificial swimmers.

  15. Computer controlled scanning systems for quantitative track measurements

    International Nuclear Information System (INIS)

    Gold, R.; Roberts, J.H.; Preston, C.C.; Ruddy, F.H.

    1982-01-01

    The status of three computer cntrolled systems for quantitative track measurements is described. Two systems, an automated optical track scanner (AOTS) and an automated scanning electron microscope (ASEM) are used for scanning solid state track recorders (SSTR). The third system, the emulsion scanning processor (ESP), is an interactive system used to measure the length of proton tracks in nuclear research emulsions (NRE). Recent advances achieved with these systems are presented, with emphasis placed upon the current limitation of these systems for reactor neutron dosimetry

  16. Optical Orbit Determination of a Geosynchronous Earth Orbit Satellite Effected by Baseline Distances between Various Ground-based Tracking Stations Ⅱ: COMS Case with Analysis of Actual Observation Data

    Directory of Open Access Journals (Sweden)

    Ju Young Son

    2015-09-01

    Full Text Available We estimated the orbit of the Communication, Ocean and Meteorological Satellite (COMS, a Geostationary Earth Orbit (GEO satellite, through data from actual optical observations using telescopes at the Sobaeksan Optical Astronomy Observatory (SOAO of the Korea Astronomy and Space Science Institute (KASI, Optical Wide field Patrol (OWL at KASI, and the Chungbuk National University Observatory (CNUO from August 1, 2014, to January 13, 2015. The astrometric data of the satellite were extracted from the World Coordinate System (WCS in the obtained images, and geometrically distorted errors were corrected. To handle the optically observed data, corrections were made for the observation time, light-travel time delay, shutter speed delay, and aberration. For final product, the sequential filter within the Orbit Determination Tool Kit (ODTK was used for orbit estimation based on the results of optical observation. In addition, a comparative analysis was conducted between the precise orbit from the ephemeris of the COMS maintained by the satellite operator and the results of orbit estimation using optical observation. The orbits estimated in simulation agree with those estimated with actual optical observation data. The error in the results using optical observation data decreased with increasing number of observatories. Our results are useful for optimizing observation data for orbit estimation.

  17. Cable Stability

    CERN Document Server

    Bottura, L

    2014-01-01

    Superconductor stability is at the core of the design of any successful cable and magnet application. This chapter reviews the initial understanding of the stability mechanism, and reviews matters of importance for stability such as the nature and magnitude of the perturbation spectrum and the cooling mechanisms. Various stability strategies are studied, providing criteria that depend on the desired design and operating conditions.

  18. Motion-based object tracking method for safety at level crossing

    Science.gov (United States)

    Salmane, Houssam; Khoudour, Louahdi; Ruichek, Yassine

    2016-09-01

    This paper presents a tracking method to detect and track independently moving targets, attempting to traverse the railway, in monocular camera sequences. This method is capable of tracking the maximum number of pixels belonging to an object. The method starts by detecting and separating moving objects due to background subtraction and an energy vector-based clustering. Next, the method performs the step of tracking locally. Tracking starts by generating initial optical flow of all object pixels by propagating the optical flow of Harris corner points (calculated by Lucas-Kanade technique) using normal distribution. An iterative procedure, including Kalman filtering with adaptive parameters, color intensity difference-based optimization, and validation constraints, is then implemented to reach precise and robust optical flow estimation for the majority of the pixels of the tracked objects. Different experimental results are presented, evaluated, and discussed to show the effectiveness of the method of tracking objects that may move in complex and overlapping trajectories.

  19. Detecting and Tracking Nonfluorescent Nanoparticles Probes in Live Cells

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Gufeng; Fang, Ning

    2012-01-17

    Precisely imaging and tracking dynamic biological processes in live cells are crucial for both fundamental research in life sciences and biomedical applications. Nonfluorescent nanoparticles are emerging as important optical probes in live-cell imaging because of their excellent photostability, large optical cross sections, and low cytotoxicity. Here, we provide a review of recent development in optical imaging of nonfluorescent nanoparticle probes and their applications in dynamic tracking and biosensing in live cells. A brief discussion on cytotoxicity of nanoparticle probes is also provided.

  20. Nanocomposites based on self-assembly poly(hydroxypropyl methacrylate)-block-poly(N-phenylmaleimide) and Fe3O4-NPs. Thermal stability, morphological characterization and optical properties

    Science.gov (United States)

    Pizarro, Guadalupe del C.; Marambio, Oscar G.; Jeria-Orell, Manuel; Sánchez, Julio; Oyarzún, Diego P.

    2018-02-01

    The current work presents the synthesis, characterization and preparation of organic-inorganic hybrid polymer films that contain inorganic magnetic nanoparticles (NPs). The block copolymer, prepared by Atom-Transfer Radical Polymerization (ATRP), was used as a nanoreactor for iron oxide NPs. The NPs were embedded in poly(hydroxypropyl methacrylate)-block-poly(N-phenylmaleimide) matrix. The following topographical modifications of the surface of the film were specially analyzed: control of pore features and changes in surface roughness. Finally, the NPs functionality inside the polymer matrix and how it may affect the thermal and optical properties of the films were assessed.

  1. Algorithms for tracking of charged particles in circular accelerators

    International Nuclear Information System (INIS)

    Iselin, F.Ch.

    1986-01-01

    An important problem in accelerator design is the determination of the largest stable betatron amplitude. This stability limit is also known as the dynamic aperture. The equations describing the particle motion are non-linear, and the Linear Lattice Functions cannot be used to compute the stability limits. The stability limits are therefore usually searched for by particle tracking. One selects a set of particles with different betatron amplitudes and tracks them for many turns around the machine. The particles which survive a sufficient number of turns are termed stable. This paper concentrates on conservative systems. For this case the particle motion can be described by a Hamiltonian, i.e. tracking particles means application of canonical transformations. Canonical transformations are equivalent to symplectic mappings, which implies that there exist invariants. These invariants should not be destroyed in tracking

  2. Stability analysis solutions and optical solitons in extended nonlinear Schrödinger equation with higher-order odd and even terms

    Science.gov (United States)

    Peng, Wei-Qi; Tian, Shou-Fu; Zou, Li; Zhang, Tian-Tian

    2018-01-01

    In this paper, the extended nonlinear Schrödinger equation with higher-order odd (third order) and even (fourth order) terms is investigated, whose particular cases are the Hirota equation, the Sasa-Satsuma equation and Lakshmanan-Porsezian-Daniel equation by selecting some specific values on the parameters of higher-order terms. We first study the stability analysis of the equation. Then, using the ansatz method, we derive its bright, dark solitons and some constraint conditions which can guarantee the existence of solitons. Moreover, the Ricatti equation extension method is employed to derive some exact singular solutions. The outstanding characteristics of these solitons are analyzed via several diverting graphics.

  3. DCS Budget Tracking System

    Data.gov (United States)

    Social Security Administration — DCS Budget Tracking System database contains budget information for the Information Technology budget and the 'Other Objects' budget. This data allows for monitoring...

  4. Stabilization of He2(A(sup 3)Sigma(sub u)(+)) molecules in liquid helium by optical pumping for vacuum UV laser

    Science.gov (United States)

    Zmuidzinas, J. S. (Inventor)

    1978-01-01

    A technique is disclosed for achieving large populations of metastable spin-aligned He2(a 3 Sigma u +) molecules in superfluid helium to obtain lasing in the vacuum ultraviolet wavelength regime around 0.0800 micron m by electronically exciting liquid (superfluid) helium with a comparatively low-current electron beam and spin aligning the metastable molecules by means of optical pumping with a modestly-powered (100mW) circularly-polarized continuous wave laser operating at, for example, 0.9096 or 0.4650 micron m. Once a high concentration of spin-aligned He2 (a 3 Sigma u +) is achieved with lifetimes of a few milliseconds, a strong microwave signal destroys the spin alignment and induces a quick collisional transition of He2 (a 3 Sigma u +) molecules to the a 1 Sigma u + state and thereby a lasing transition to the X 1 Sigma g + state.

  5. Complex Dynamical Network Control for Trajectory Tracking Using Delayed Recurrent Neural Networks

    Directory of Open Access Journals (Sweden)

    Jose P. Perez

    2014-01-01

    Full Text Available In this paper, the problem of trajectory tracking is studied. Based on the V-stability and Lyapunov theory, a control law that achieves the global asymptotic stability of the tracking error between a delayed recurrent neural network and a complex dynamical network is obtained. To illustrate the analytic results, we present a tracking simulation of a dynamical network with each node being just one Lorenz’s dynamical system and three identical Chen’s dynamical systems.

  6. Observation of single artificial atom optical bi-stability and its application to single-shot readout in circuit quantum electrodynamics

    Science.gov (United States)

    Sun, Luyan; Ginossar, Eran; Guy, Mikhael; Reed, Matthew; Paik, Hanhee; Bishop, Lev S.; Sears, Adam; Petrenko, Andrei; Brecht, Teresa; Frunzio, Luigi; Girvin, Steven; Schoelkopf, Robert

    2012-02-01

    The high power transient behavior of superconducting qubit-cavity systems has recently been used to perform high fidelity readout of transmon qubits [1]. We show that in the steady state, the system exhibits a bi-stable behavior that can be observed on the single-shot level, with the cavity state switching stochastically between dim and bright states. The switching times are shown to be long compared to the cavity and qubit lifetimes. Some features of the bi-stability can be explained by mean field theory, while its switching dynamics is studied with large scale simulations. Understanding these dynamics will be crucial for studying the transient response, an essential aspect of the qubit readout. We will discuss progress on optimizing readout by shaping the measurement pulse. [4pt] [1] M. D. Reed, L. DiCarlo, B. R. Johnson, L. Sun, D. I. Schuster, L. Frunzio, and R. J. Schoelkopf, Phys. Rev. Lett. 105, 173601 (2010)

  7. CWI at TREC 2012, KBA track and Session Track

    NARCIS (Netherlands)

    S. Araújo (Samur); C. Boscarino (Corrado); G.G. Gebremeskel (Gebre); J. He (Jiyin); A.P. de Vries (Arjen); E.M. Voorhees; L. P. Buckland (Buckland, Lori P.)

    2013-01-01

    htmlabstractWe participated in two tracks: Knowledge Base Acceleration (KBA) Track and Session Track. In the KBA track, we focused on experi- menting with different approaches as it is the first time the track is launched. We experimented with supervised and unsupervised re- trieval models. Our

  8. Optic neuritis

    Science.gov (United States)

    Retro-bulbar neuritis; Multiple sclerosis - optic neuritis; Optic nerve - optic neuritis ... The exact cause of optic neuritis is unknown. The optic nerve carries visual information from your eye to the brain. The nerve can swell when ...

  9. Holographic 3D tracking of microscopic tools

    DEFF Research Database (Denmark)

    Glückstad, Jesper; Villangca, Mark Jayson; Bañas, Andrew Rafael

    2015-01-01

    We originally proposed and experimentally demonstrated the targeted-light delivery capability of so-called Wave-guided Optical Waveguides (WOWs) three years ago. As these WOWs are maneuvered in 3D space, it is important to maintain efficient light coupling through their integrated waveguide...... demonstrated dynamic tracking and coupling for both lateral and axial displacements of the WOWs. The ability to switch from on-demand to continuous addressing with efficient illumination leverages our WOWs for potential applications in near-field stimulation and nonlinear optics at small scales....

  10. Mobile Tracking Systems Using Meter Class Reflective Telescopes

    Science.gov (United States)

    Sturzenbecher, K.; Ehrhorn, B.

    This paper is a discussion on the use of large reflective telescopes on mobile tracking systems with modern instrument control systems. Large optics can be defined as reflective telescopes with an aperture of at least 20 inches in diameter. New carbon composite construction techniques allow for larger, stronger, and lighter telescopes ranging from 240 pounds for a 20 inch, to 800 pounds for a 32 inch, making them ideal for mobile tracking systems. These telescopes have better light gathering capability and produce larger images with greater detail at a longer range than conventional refractive lenses. In a mobile configuration these systems provide the ability to move the observation platform to the optimal location anywhere in the world. Mounting and systems integration - We will discuss how large telescopes can be physically fit to the mobile tracking system and the integration with the tracking systems' digital control system. We will highlight the remote control capabilities. We will discuss special calibration techniques available in a modern instrument control system such as star calibration, calibration of sensors. Tracking Performance - We will discuss the impact of using large telescopes on the performance of the mobile tracking system. We will highlight the capabilities for auto-tracking and sidereal rate tracking in a mobile mount. Large optics performance - We will discuss the advantages of two-mirror Ritchey-Chrétien reflective optics which offer in-focus imaging across the spectrum, from visible to Long Wave Infrared. These zero expansion optics won't lose figure or focus during temperature changes. And the carbon composite telescope tube is thermally inert. The primary mirror is a modern lightweight "dish" mirror for low thermal mass and is center supported/self balancing. Applications - We will discuss Visible - IR Imaging requirements, Optical Rangefinders, and capabilities for special filters to increase resolution in difficult conditions such as

  11. Long-Term Stability of Social Participation

    Science.gov (United States)

    Hyyppa, Markku T.; Maki, Juhani; Alanen, Erkki; Impivaara, Olli; Aromaa, Arpo

    2008-01-01

    The long-term stability of social participation was investigated in a representative urban population of 415 men and 579 women who had taken part in the nationwide Mini-Finland Health Survey in the years 1978-1980 and were re-examined 20 years later. Stability was assessed by means of the following tracking coefficients: kappa, proportion of…

  12. Stability of the response and dependence of the optical signal as function of dose rate of the alanine gel dosimeter for electron clinic beams; Estabilidade da resposta e dependencia do sinal optico em funcao da taxa de dose do dosimetro alanina gel para feixes clinicos de eletrons

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Cleber Feijo; Dias, Daniel Menezes; Campos, Leticia Lucente, E-mail: cfsilva@ipen.b, E-mail: dmdias@ipen.b, E-mail: lcrodri@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    This work evaluates the stability of response and the dependence on the optical response of dose rate of the alanine gel solution developed at the IPEN, Sao Paulo, Brazil, for possible future usage as 3D dosemeter in the medical area, as the area is lack of measure instrumentation for three dimension dose

  13. Incentives from Curriculum Tracking

    Science.gov (United States)

    Koerselman, Kristian

    2013-01-01

    Curriculum tracking creates incentives in the years before its start, and we should therefore expect test scores to be higher during those years. I find robust evidence for incentive effects of tracking in the UK based on the UK comprehensive school reform. Results from the Swedish comprehensive school reform are inconclusive. Internationally, I…

  14. UWB Tracking Software Development

    Science.gov (United States)

    Gross, Julia; Arndt, Dickey; Ngo, Phong; Phan, Chau; Dusl, John; Ni, Jianjun; Rafford, Melinda

    2006-01-01

    An Ultra-Wideband (UWB) two-cluster Angle of Arrival (AOA) tracking prototype system is currently being developed and tested at NASA Johnson Space Center for space exploration applications. This talk discusses the software development efforts for this UWB two-cluster AOA tracking system. The role the software plays in this system is to take waveform data from two UWB radio receivers as an input, feed this input into an AOA tracking algorithm, and generate the target position as an output. The architecture of the software (Input/Output Interface and Algorithm Core) will be introduced in this talk. The development of this software has three phases. In Phase I, the software is mostly Matlab driven and calls C++ socket functions to provide the communication links to the radios. This is beneficial in the early stage when it is necessary to frequently test changes in the algorithm. Phase II of the development is to have the software mostly C++ driven and call a Matlab function for the AOA tracking algorithm. This is beneficial in order to send the tracking results to other systems and also to improve the tracking update rate of the system. The third phase is part of future work and is to have the software completely C++ driven with a graphics user interface. This software design enables the fine resolution tracking of the UWB two-cluster AOA tracking system.

  15. Attitude and position tracking

    CSIR Research Space (South Africa)

    Candy, LP

    2011-01-01

    Full Text Available Several applications require the tracking of attitude and position of a body based on velocity data. It is tempting to use direction cosine matrices (DCM), for example, to track attitude based on angular velocity data, and to integrate the linear...

  16. Eye-Tracking

    Directory of Open Access Journals (Sweden)

    Gabriela GROSSECK

    2006-01-01

    Full Text Available Eye-tracking: one of the newest and most efficient methods of improving on-line marketing communication is called eye-tracking. Marketers have borrowed this technique, usually used in psychological and medical research, in order to study web users with the help of a video camera incorporated in the monitor.

  17. Large scale tracking algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, Ross L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Love, Joshua Alan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Melgaard, David Kennett [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Karelitz, David B. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Pitts, Todd Alan [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Zollweg, Joshua David [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Anderson, Dylan Z. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Nandy, Prabal [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Whitlow, Gary L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bender, Daniel A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Byrne, Raymond Harry [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-01-01

    Low signal-to-noise data processing algorithms for improved detection, tracking, discrimination and situational threat assessment are a key research challenge. As sensor technologies progress, the number of pixels will increase signi cantly. This will result in increased resolution, which could improve object discrimination, but unfortunately, will also result in a significant increase in the number of potential targets to track. Many tracking techniques, like multi-hypothesis trackers, suffer from a combinatorial explosion as the number of potential targets increase. As the resolution increases, the phenomenology applied towards detection algorithms also changes. For low resolution sensors, "blob" tracking is the norm. For higher resolution data, additional information may be employed in the detection and classfication steps. The most challenging scenarios are those where the targets cannot be fully resolved, yet must be tracked and distinguished for neighboring closely spaced objects. Tracking vehicles in an urban environment is an example of such a challenging scenario. This report evaluates several potential tracking algorithms for large-scale tracking in an urban environment.

  18. Why we are tracking

    DEFF Research Database (Denmark)

    Tække, Jesper

    2015-01-01

    In this short essay, concerning why we are tracking, I will try to frame tracking as an evolutionary developed skill that humans need to survive. From an evolutionary point zero life must reflect upon itself in regard to its surrounding world as a kind of societal self-synchronization in this reg......In this short essay, concerning why we are tracking, I will try to frame tracking as an evolutionary developed skill that humans need to survive. From an evolutionary point zero life must reflect upon itself in regard to its surrounding world as a kind of societal self......-synchronization in this regard (Spencer 1890, Luhmann 2000, Tække 2014, 2011). I was inspired by Jill Walker Rettberg’s book: “Seeing Ourselves through Technology” and her presentation at the seminar: “Tracking Culture” arranged by Anders Albrechtslund in Aarhus January 2015....

  19. Development of a railway wagon-track interaction model: Case studies on excited tracks

    Science.gov (United States)

    Xu, Lei; Chen, Xianmai; Li, Xuwei; He, Xianglin

    2018-02-01

    In this paper, a theoretical framework for modeling the railway wagon-ballast track interactions is presented, in which the dynamic equations of motion of wagon-track systems are constructed by effectively coupling the linear and nonlinear dynamic characteristics of system components. For the linear components, the energy-variational principle is directly used to derive their dynamic matrices, while for the nonlinear components, the dynamic equilibrium method is implemented to deduce the load vectors, based on which a novel railway wagon-ballast track interaction model is developed, and being validated by comparing with the experimental data measured from a heavy haul railway and another advanced model. With this study, extensive contributions in figuring out the critical speed of instability, limits and localizations of track irregularities over derailment accidents are presented by effectively integrating the dynamic simulation model, the track irregularity probabilistic model and time-frequency analysis method. The proposed approaches can provide crucial information to guarantee the running safety and stability of the wagon-track system when considering track geometries and various running speeds.

  20. Improvement of stability and efficiency in diode-pumped passively Q-switched intracavity optical parametric oscillator with a monolithic cavity

    International Nuclear Information System (INIS)

    Huang, J Y; Zhuang, W Z; Huang, Y P; Huang, Y J; Su, K W; Chen, Y F

    2012-01-01

    We improve the performance of intracavity optical parametric oscillator (IOPO) pumped by a diode-pumped Q-switched Nd:YVO 4 /Cr 4+ :YAG laser. The IOPO cavity is formed independently by a monolithic KTP crystal that the mirrors are directly deposited on top of the nonlinear crystal. We study the performances of this IOPO cavity with different reflectivity of the output coupler at 1.5 μm (R s ) of 80 and 50%. The average power of 1.5 μm is up to 3.3 W at the maximum pump power of 16.8 W for both cases. The diode-to-signal conversion efficiency is up to 20%, which is the highest one for IOPOs to our best knowledge. At the maximum pump power, the pulse energies are 41 μJ with the pulse width of 3 ns at a pulse repetition rate (PRR) of 80 kHz for R s = 80% and 51 μJ with the pulse width of 1.2 ns at a PRR of 65 kHz for R s = 50%, respectively. The pulse amplitude fluctuations in standard deviation are 2.6% for R s = 80% and 4% for R s = 50%, respectively

  1. Intrinsically Radioactive [64Cu]CuInS/ZnS Quantum Dots for PET and Optical Imaging: Improved Radiochemical Stability and Controllable Cerenkov Luminescence

    Science.gov (United States)

    2015-01-01

    Functionalized quantum dots (QDs) have been widely explored for multimodality bioimaging and proven to be versatile agents. Attaching positron-emitting radioisotopes onto QDs not only endows their positron emission tomography (PET) functionality, but also results in self-illuminating QDs, with no need for an external light source, by Cerenkov resonance energy transfer (CRET). Traditional chelation methods have been used to incorporate the radionuclide, but these methods are compromised by the potential for loss of radionuclide due to cleavage of the linker between particle and chelator, decomplexation of the metal, and possible altered pharmacokinetics of nanomaterials. Herein, we described a straightforward synthesis of intrinsically radioactive [64Cu]CuInS/ZnS QDs by directly incorporating 64Cu into CuInS/ZnS nanostructure with 64CuCl2 as synthesis precursor. The [64Cu]CuInS/ZnS QDs demonstrated excellent radiochemical stability with less than 3% free 64Cu detected even after exposure to serum containing EDTA (5 mM) for 24 h. PEGylation can be achieved in situ during synthesis, and the PEGylated radioactive QDs showed high tumor uptake (10.8% ID/g) in a U87MG mouse xenograft model. CRET efficiency was studied as a function of concentration and 64Cu radioactivity concentration. These [64Cu]CuInS/ZnS QDs were successfully applied as an efficient PET/self-illuminating luminescence in vivo imaging agents. PMID:25549258

  2. Intrinsically radioactive [64Cu]CuInS/ZnS quantum dots for PET and optical imaging: improved radiochemical stability and controllable Cerenkov luminescence.

    Science.gov (United States)

    Guo, Weisheng; Sun, Xiaolian; Jacobson, Orit; Yan, Xuefeng; Min, Kyunghyun; Srivatsan, Avinash; Niu, Gang; Kiesewetter, Dale O; Chang, Jin; Chen, Xiaoyuan

    2015-01-27

    Functionalized quantum dots (QDs) have been widely explored for multimodality bioimaging and proven to be versatile agents. Attaching positron-emitting radioisotopes onto QDs not only endows their positron emission tomography (PET) functionality, but also results in self-illuminating QDs, with no need for an external light source, by Cerenkov resonance energy transfer (CRET). Traditional chelation methods have been used to incorporate the radionuclide, but these methods are compromised by the potential for loss of radionuclide due to cleavage of the linker between particle and chelator, decomplexation of the metal, and possible altered pharmacokinetics of nanomaterials. Herein, we described a straightforward synthesis of intrinsically radioactive [(64)Cu]CuInS/ZnS QDs by directly incorporating (64)Cu into CuInS/ZnS nanostructure with (64)CuCl2 as synthesis precursor. The [(64)Cu]CuInS/ZnS QDs demonstrated excellent radiochemical stability with less than 3% free (64)Cu detected even after exposure to serum containing EDTA (5 mM) for 24 h. PEGylation can be achieved in situ during synthesis, and the PEGylated radioactive QDs showed high tumor uptake (10.8% ID/g) in a U87MG mouse xenograft model. CRET efficiency was studied as a function of concentration and (64)Cu radioactivity concentration. These [(64)Cu]CuInS/ZnS QDs were successfully applied as an efficient PET/self-illuminating luminescence in vivo imaging agents.

  3. Comparing blends and blocks: Synthesis of partially fluorinated diblock polythiophene copolymers to investigate the thermal stability of optical and morphological properties

    Directory of Open Access Journals (Sweden)

    Pierre Boufflet

    2016-10-01

    Full Text Available The microstructure of the active blend layer has been shown to be a critically important factor in the performance of organic solar devices. Block copolymers provide a potentially interesting avenue for controlling this active layer microstructure in solar cell blends. Here we explore the impact of backbone fluorination in block copolymers of poly(3-octyl-4-fluorothiophenes and poly(3-octylthiophene (F-P3OT-b-P3OT. Two block co-polymers with varying block lengths were prepared via sequential monomer addition under Kumada catalyst transfer polymerisation (KCTP conditions. We compare the behavior of the block copolymer to that of the corresponding homopolymer blends. In both types of system, we find the fluorinated segments tend to dominate the UV–visible absorption and molecular vibrational spectral features, as well as the thermal behavior. In the block copolymer case, non-fluorinated segments appear to slightly frustrate the aggregation of the more fluorinated block. However, in situ temperature dependent Raman spectroscopy shows that the intramolecular order is more thermally stable in the block copolymer than in the corresponding blend, suggesting that such materials may be interesting for enhanced thermal stability of organic photovoltaic active layers based on similar systems.

  4. Scale adaptive compressive tracking.

    Science.gov (United States)

    Zhao, Pengpeng; Cui, Shaohui; Gao, Min; Fang, Dan

    2016-01-01

    Recently, the compressive tracking (CT) method (Zhang et al. in Proceedings of European conference on computer vision, pp 864-877, 2012) has attracted much attention due to its high efficiency, but it cannot well deal with the scale changing objects due to its constant tracking box. To address this issue, in this paper we propose a scale adaptive CT approach, which adaptively adjusts the scale of tracking box with the size variation of the objects. Our method significantly improves CT in three aspects: Firstly, the scale of tracking box is adaptively adjusted according to the size of the objects. Secondly, in the CT method, all the compressive features are supposed independent and equal contribution to the classifier. Actually, different compressive features have different confidence coefficients. In our proposed method, the confidence coefficients of features are computed and used to achieve different contribution to the classifier. Finally, in the CT method, the learning parameter λ is constant, which will result in large tracking drift on the occasion of object occlusion or large scale appearance variation. In our proposed method, a variable learning parameter λ is adopted, which can be adjusted according to the object appearance variation rate. Extensive experiments on the CVPR2013 tracking benchmark demonstrate the superior performance of the proposed method compared to state-of-the-art tracking algorithms.

  5. Analysis and design of microprocessor-controlled peak-power-tracking system

    OpenAIRE

    Huynh, Phuong

    1992-01-01

    Analyses and designs of a peak-power tracking system using microprocessor control are performed. Large-signal stability of the system for various modes of operation is analyzed to predict system dynamics. The stability analysis is supported mainly by qualitative graphical representations of different component blocks of the system. Small-signal stability analysis around the equilibrium points is done to assure proper performance and operation of this particular peak-power track...

  6. Robust tracking with spatio-velocity snakes: Kalman filtering approach

    Energy Technology Data Exchange (ETDEWEB)

    Peterfreund, N.

    1998-12-31

    Using results from robust Kalman filtering, we present a new Kalman filter-based snake model for tracking of nonrigid objects in combined spatio-velocity space. The proposed model is the stochastic version of the velocity snake, an active contour model for combined tracking of position and velocity of nonrigid boundaries. The proposed model uses image gradient and optical flow measurements along the contour as system measurements. An optical-flow based measurement error is used to detect and reject image measurements which correspond to image clutter or to other objects. The method was applied to object tracking of both rigid and nonrigid objects, resulting in good tracking results and robustness to image clutter, occlusions and numerical noise. 19 refs., 3 figs.

  7. Robust tracking with spatio-velocity snakes: Kalman filtering approach

    Energy Technology Data Exchange (ETDEWEB)

    Peterfreund, N.

    1997-06-01

    Using results from robust Kalman filtering, the author presents a new Kalman filter-based snake model for tracking of nonrigid objects in combined spatio-velocity space. The proposed model is the stochastic version of the velocity snake, an active contour model for combined tracking of position and velocity of nonrigid boundaries. The proposed model uses image gradient and optical flow measurements along the contour as system measurements. An optical-flow based measurement error is used to detect and reject image measurements which correspond to image clutter or to other objects. The method was applied to object tracking of both rigid and nonrigid objects, resulting in good tracking results and robustness to image clutter, occlusions and numerical noise.

  8. PREDICT: Satellite tracking and orbital prediction

    Science.gov (United States)

    Magliacane, John A.

    2011-12-01

    PREDICT is an open-source, multi-user satellite tracking and orbital prediction program written under the Linux operating system. PREDICT provides real-time satellite tracking and orbital prediction information to users and client applications through: the system console the command line a network socket the generation of audio speechData such as a spacecraft's sub-satellite point, azimuth and elevation headings, Doppler shift, path loss, slant range, orbital altitude, orbital velocity, footprint diameter, orbital phase (mean anomaly), squint angle, eclipse depth, the time and date of the next AOS (or LOS of the current pass), orbit number, and sunlight and visibility information are provided on a real-time basis. PREDICT can also track (or predict the position of) the Sun and Moon. PREDICT has the ability to control AZ/EL antenna rotators to maintain accurate orientation in the direction of communication satellites. As an aid in locating and tracking satellites through optical means, PREDICT can articulate tracking coordinates and visibility information as plain speech.

  9. Tracking-integrated systems for concentrating photovoltaics

    Science.gov (United States)

    Apostoleris, Harry; Stefancich, Marco; Chiesa, Matteo

    2016-04-01

    Concentrating photovoltaic (CPV) systems, which use optical elements to focus light onto small-area solar cells, have the potential to minimize the costs, while improving efficiency, of photovoltaic technology. However, CPV is limited by the need to track the apparent motion of the Sun. This is typically accomplished using high-precision mechanical trackers that rotate the entire module to maintain normal light incidence. These machines are large, heavy and expensive to build and maintain, deterring commercial interest and excluding CPV from the residential market. To avoid this issue, some attention has recently been devoted to the development of tracking-integrated systems, in which tracking is performed inside the CPV module itself. This creates a compact system geometry that could be less expensive and more suitable for rooftop installation than existing CPV trackers. We review the basic tracking principles and concepts exploited in these systems, describe and categorize the existing designs, and discuss the potential impact of tracking integration on CPV cost models and commercial potential.

  10. Fast track-hoftealloplastik

    DEFF Research Database (Denmark)

    Hansen, Torben Bæk; Gromov, Kirill; Kristensen, Billy B

    2017-01-01

    Fast-track surgery implies a coordinated perioperative approach aimed at reducing surgical stress and facilitating post-operative recovery. The fast-track programme has reduced post-operative length of stay and has led to shorter convalescence with more rapid functional recovery and decreased...... morbidity and mortality in total hip arthroplasty. It should now be a standard total hip arthroplasty patient pathway, but fine tuning of the multiple factors in the fast-track pathway is still needed in patients with special needs or high comorbidity burden....

  11. Facile, one-pot and scalable synthesis of highly emissive aqueous-based Ag,Ni:ZnCdS/ZnS core/shell quantum dots with high chemical and optical stability

    Science.gov (United States)

    Sahraei, Reza; Soheyli, Ehsan; Faraji, Zahra; Soleiman-Beigi, Mohammad

    2017-11-01

    We report here on a one-pot, mild and low cost aqueous-based synthetic route for the preparation of colloidally stable and highly luminescent dual-doped Ag,Ni:ZnCdS/ZnS core/shell quantum dots (QDs). The pure dopant emission of the Ni-doped core/shell QDs was found to be highly affected by the presence of a second dopant ion (Ag+). Results showed that the PL emission intensity increases while its peak position experiences an obvious blue shift with an increase in the content of Ag+ ions. Regarding the optical observations, we provide a simple scheme for absorption-recombination processes of the carriers through impurity centers. To obtain optimum conditions with a better emission characteristic, we also study the effect of different reaction parameters, such as refluxing temperature, the pH of the core and shell solution, molar ratio of the dopant ions (Ni:(Zn+Cd) and Ag:(Zn+Cd)), and concentration of the core and shell precursors. Nonetheless, the most effective parameter is the presence of the ZnS shell in a suitable amount to eliminate surface trap states and enhance their emission intensity. It can also improve the bio-compatibility of the prepared QDs by restricting the Cd2+ toxic ions inside the core of the QDs. The present suggested route also revealed the remarkable optical and chemical stability of the colloidal QDs which establishes them as a decent kind of nano-scale structure for light emitting applications, especially in biological technologies. The suggested process also has the potential to be scaled-up while maintaining the emission characteristics and structural quality necessary for industrial applications in optoelectronic devices.

  12. Facile, one-pot and scalable synthesis of highly emissive aqueous-based Ag,Ni:ZnCdS/ZnS core/shell quantum dots with high chemical and optical stability.

    Science.gov (United States)

    Sahraei, Reza; Soheyli, Ehsan; Faraji, Zahra; Soleiman-Beigi, Mohammad

    2017-11-24

    We report here on a one-pot, mild and low cost aqueous-based synthetic route for the preparation of colloidally stable and highly luminescent dual-doped Ag,Ni:ZnCdS/ZnS core/shell quantum dots (QDs). The pure dopant emission of the Ni-doped core/shell QDs was found to be highly affected by the presence of a second dopant ion (Ag + ). Results showed that the PL emission intensity increases while its peak position experiences an obvious blue shift with an increase in the content of Ag + ions. Regarding the optical observations, we provide a simple scheme for absorption-recombination processes of the carriers through impurity centers. To obtain optimum conditions with a better emission characteristic, we also study the effect of different reaction parameters, such as refluxing temperature, the pH of the core and shell solution, molar ratio of the dopant ions (Ni:(Zn+Cd) and Ag:(Zn+Cd)), and concentration of the core and shell precursors. Nonetheless, the most effective parameter is the presence of the ZnS shell in a suitable amount to eliminate surface trap states and enhance their emission intensity. It can also improve the bio-compatibility of the prepared QDs by restricting the Cd 2+ toxic ions inside the core of the QDs. The present suggested route also revealed the remarkable optical and chemical stability of the colloidal QDs which establishes them as a decent kind of nano-scale structure for light emitting applications, especially in biological technologies. The suggested process also has the potential to be scaled-up while maintaining the emission characteristics and structural quality necessary for industrial applications in optoelectronic devices.

  13. Real-time tumor tracking in the lung using an electromagnetic tracking system.

    Science.gov (United States)

    Shah, Amish P; Kupelian, Patrick A; Waghorn, Benjamin J; Willoughby, Twyla R; Rineer, Justin M; Mañon, Rafael R; Vollenweider, Mark A; Meeks, Sanford L

    2013-07-01

    To describe the first use of the commercially available Calypso 4D Localization System in the lung. Under an institutional review board-approved protocol and an investigational device exemption from the US Food and Drug Administration, the Calypso system was used with nonclinical methods to acquire real-time 4-dimensional lung tumor tracks for 7 lung cancer patients. The aims of the study were to investigate (1) the potential for bronchoscopic implantation; (2) the stability of smooth-surface beacon transponders (transponders) after implantation; and (3) the ability to acquire tracking information within the lung. Electromagnetic tracking was not used for any clinical decision making and could only be performed before any radiation delivery in a research setting. All motion tracks for each patient were reviewed, and values of the average displacement, amplitude of motion, period, and associated correlation to a sinusoidal model (R(2)) were tabulated for all 42 tracks. For all 7 patients at least 1 transponder was successfully implanted. To assist in securing the transponder at the tumor site, it was necessary to implant a secondary fiducial for most transponders owing to the transponder's smooth surface. For 3 patients, insertion into the lung proved difficult, with only 1 transponder remaining fixed during implantation. One patient developed a pneumothorax after implantation of the secondary fiducial. Once implanted, 13 of 14 transponders remained stable within the lung and were successfully tracked with the tracking system. Our initial experience with electromagnetic guidance within the lung demonstrates that transponder implantation and tracking is achievable though not clinically available. This research investigation proved that lung tumor motion exhibits large variations from fraction to fraction within a single patient and that improvements to both transponder and tracking system are still necessary to create a clinical daily-use system to assist with actual

  14. Object Tracking by Oversampling Local Features.

    Science.gov (United States)

    Pernici, Federico; Del Bimbo, Alberto

    2014-12-01

    In this paper, we present the ALIEN tracking method that exploits oversampling of local invariant representations to build a robust object/context discriminative classifier. To this end, we use multiple instances of scale invariant local features weakly aligned along the object template. This allows taking into account the 3D shape deviations from planarity and their interactions with shadows, occlusions, and sensor quantization for which no invariant representations can be defined. A non-parametric learning algorithm based on the transitive matching property discriminates the object from the context and prevents improper object template updating during occlusion. We show that our learning rule has asymptotic stability under mild conditions and confirms the drift-free capability of the method in long-term tracking. A real-time implementation of the ALIEN tracker has been evaluated in comparison with the state-of-the-art tracking systems on an extensive set of publicly available video sequences that represent most of the critical conditions occurring in real tracking environments. We have reported superior or equal performance in most of the cases and verified tracking with no drift in very long video sequences.

  15. Tracking studies in eRHIC energy-recovery recirculator

    Energy Technology Data Exchange (ETDEWEB)

    Meot, F. [Brookhaven National Lab. (BNL), Upton, NY (United States); Brooks, S. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ptitsyn, V. [Brookhaven National Lab. (BNL), Upton, NY (United States); Trbojevic, D. [Brookhaven National Lab. (BNL), Upton, NY (United States); Tsoupas, N. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-07-13

    Beam and polarization tracking studies in eRHIC energy recovery electron recirculator are presented, based on a very preliminary design of the FFAG lattice. These simulations provide examples of some of the beam and spin optics aspects of the linear FFAG lattice concept and its application in eRHIC, they provide code benchmarking for synchrotron radiation and spin diffusion in addition, and pave the way towards end-to-end 6-D(phasespace)+3D(spin) tracking simulations.

  16. Agency Correspondence Tracking System (ACTS)

    Data.gov (United States)

    US Agency for International Development — Agency Correspondence Tracking System: is an executive correspondence tracking system for the Administrator. It collects and organizes information on reports...

  17. Applied eye tracking research

    NARCIS (Netherlands)

    Jarodzka, Halszka

    2011-01-01

    Jarodzka, H. (2010, 12 November). Applied eye tracking research. Presentation and Labtour for Vereniging Gewone Leden in oprichting (VGL i.o.), Heerlen, The Netherlands: Open University of the Netherlands.

  18. Energy Tracking Software Platform

    Energy Technology Data Exchange (ETDEWEB)

    Ryan Davis; Nathan Bird; Rebecca Birx; Hal Knowles

    2011-04-04

    Acceleration has created an interactive energy tracking and visualization platform that supports decreasing electric, water, and gas usage. Homeowners have access to tools that allow them to gauge their use and track progress toward a smaller energy footprint. Real estate agents have access to consumption data, allowing for sharing a comparison with potential home buyers. Home builders have the opportunity to compare their neighborhood's energy efficiency with competitors. Home energy raters have a tool for gauging the progress of their clients after efficiency changes. And, social groups are able to help encourage members to reduce their energy bills and help their environment. EnergyIT.com is the business umbrella for all energy tracking solutions and is designed to provide information about our energy tracking software and promote sales. CompareAndConserve.com (Gainesville-Green.com) helps homeowners conserve energy through education and competition. ToolsForTenants.com helps renters factor energy usage into their housing decisions.

  19. LHCb on track

    CERN Document Server

    2006-01-01

    On 7 and 8 June 2006, the last large component of the LHCb experiment was lowered into the cavern. This 10-tonne, 18-metre long metal structure known as 'the bridge' will support the LHCb tracking system.

  20. LHCb VELO Tracking Resolutions

    CERN Multimedia

    Alexander, Michael

    2011-01-01

    The excellent tracking performance of the Vertex Locator (VELO) at LHCb is presented. The resolutions it achieves on single hits, impact parameters, and primary vertex positions are shown, with particular attention paid to measurement of impact parameters.

  1. Track Loading Vehicle - TLV

    Data.gov (United States)

    Federal Laboratory Consortium — The TLV is designed to apply forces close to the strength limits of the rails and other track structure components, such as ties, rail fasteners, and ballast, while...

  2. Matter Tracking Information System -

    Data.gov (United States)

    Department of Transportation — The Matter Tracking Information System (MTIS) principle function is to streamline and integrate the workload and work activity generated or addressed by our 300 plus...

  3. Case Analysis Tracking System

    Data.gov (United States)

    National Archives and Records Administration — CATS tracks Public and Federal Agency Reference Requests for OPF (Official Personnel Folder) , EMF (Employee Medical Folder), and eOPF (electronic Official Personnel...

  4. MARS PATHFINDER RADIO TRACKING

    Data.gov (United States)

    National Aeronautics and Space Administration — The Mars Pathfinder (MPF) Radio Science (RS) data archive contains both raw radio tracking data collected during the surface lifetime of the MPF Lander and results...

  5. Financial Disclosure Tracking System

    Data.gov (United States)

    US Agency for International Development — USAID's FDTS identifies personal service contractors and local employees who should file disclosure reports. It tracks late filers and identifies those who must take...

  6. Human Capital Tracking Tool -

    Data.gov (United States)

    Department of Transportation — AVS is now required to collect, track, and report on data from the following Flight, Business and Workforce Plan. The Human Resource Management’s Performance Target...

  7. Procurement Tracking System (PTS)

    Data.gov (United States)

    Office of Personnel Management — The Procurement Tracking System (PTS) is used solely by the procurement staff of the Office of the Inspector General (OIG) at the U.S. Office of Personnel Management...

  8. Jet Car Track Site

    Data.gov (United States)

    Federal Laboratory Consortium — Located in Lakehurst, New Jersey, the Jet Car Track Site supports jet cars with J57 engines and has a maximum jet car thrust of 42,000 pounds with a maximum speed of...

  9. Optically pumped laser systems

    International Nuclear Information System (INIS)

    DeMaria, A.J.; Mack, M.E.

    1975-01-01

    Laser systems which are pumped by an electric discharge formed in a gas are disclosed. The discharge is in the form of a vortex stabilized electric arc which is triggered with an auxiliary energy source. At high enough repetition rates residual ionization between successive pulses contributes to the pulse stabilization. The arc and the gain medium are positioned inside an optical pumping cavity where light from the arc is coupled directly into the gain medium

  10. Function integrated track system

    OpenAIRE

    Hohnecker, Eberhard

    2010-01-01

    The paper discusses a function integrated track system that focuses on the reduction of acoustic emissions from railway lines. It is shown that the combination of an embedded rail system (ERS), a sound absorbing track surface, and an integrated mini sound barrier has significant acoustic advantages compared to a standard ballast superstructure. The acoustic advantages of an embedded rail system are particularly pronounced in the case of railway bridges. Finally, it is shown that a...

  11. Material Tracking Using LANMAS

    International Nuclear Information System (INIS)

    Armstrong, F.

    2010-01-01

    LANMAS is a transaction-based nuclear material accountability software product developed to replace outdated and legacy accountability systems throughout the DOE. The core underlying purpose of LANMAS is to track nuclear materials inventory and report transactions (movement, mixing, splitting, decay, etc.) to the Nuclear Materials Management and Safeguards System (NMMSS). While LANMAS performs those functions well, there are many additional functions provided by the software product. As a material is received onto a site or created at a site, its entire lifecycle can be tracked in LANMAS complete to its termination of safeguards. There are separate functions to track material movements between and within material balance areas (MBAs). The level of detail for movements within a MBA is configurable by each site and can be as high as a site designation or as detailed as building/room/rack/row/position. Functionality exists to track the processing of materials, either as individual items or by modeling a bulk process as an individual item to track inputs and outputs from the process. In cases where sites have specialized needs, the system is designed to be flexible so that site specific functionality can be integrated into the product. This paper will demonstrate how the software can be used to input material into an account and track it to its termination of safeguards.

  12. Nuclear tracks in solids

    International Nuclear Information System (INIS)

    Espinosa G, G.

    1994-01-01

    The main purpose of this book is to dispose within reach of young professionals in the fields of Physics, Biology, Chemistry, Medicine, Geology, Earth Sciences and Ecology between others, the basis of the Solid State Nuclear Track Methodology (SSNTM). The contents of this book is distributed as follows: Chapter 1, occurs the basic aspects on the formation of tracks in solid state materials. Chapter 2 analyzes the formation of the solid state nuclear tracks in order to three fundamental steps in the process: ionizing radiation, chemical revealed of the track and characterization and reading of the tracks. In the chapter 3, was made an analysis of the possible materials like detecting for tracks, describing the experimental process for the parameters optimization and they are also specified the characteristics of the instrumentation developed for the STD. In the chapter 4, the results obtained in applications are shown specify of the STD, where it was made emphasis in the evaluation of radon within the city and the determination of profiles and pollutants of transuranic radioactive materials. In the chapter 5, it was made an analysis of the applications of the STD as well as their future perspectives in the fields of the science and the technology. Finally, in the conclusions summary the excellent aspects of each one of the chapters and the general results are presented. (Author)

  13. An adaptive sliding mode control technology for weld seam tracking

    Science.gov (United States)

    Liu, Jie; Hu, Youmin; Wu, Bo; Zhou, Kaibo; Ge, Mingfeng

    2015-03-01

    A novel adaptive sliding mode control algorithm is derived to deal with seam tracking control problem of welding robotic manipulator, during the process of large-scale structure component welding. The proposed algorithm does not require the precise dynamic model, and is more practical. Its robustness is verified by the Lyapunov stability theory. The analytical results show that the proposed algorithm enables better high-precision tracking performance with chattering-free than traditional sliding mode control algorithm under various disturbances.

  14. Self Tuning Sliding Mode Control for Quadrotor Waypoint Tracking

    OpenAIRE

    Istiqphara, Swadexi; Agustinah, Trihastuti; Fatoni, Ali

    2015-01-01

    In this paper, self-tuning sliding mode control is proposed to control quadrotor with mass parameter uncertainty on waypoint trajectory tracking. Parameter uncertainty is one of the factor that cause instability of quadrotor. Self-tuning sliding mode control is used to maintain the stability of quadrotor in this parametric uncertainties condition. The simulation results show that the quadrotor can track the waypoint trajectory in the presence of parameter uncertainty.

  15. Alpha particle track coloration in CR-39: Improved observability

    CERN Document Server

    Oezguemues, A

    1999-01-01

    A comparative study of the observability of alpha particle tracks in CR-39 was performed with an optical microscope before and after coloration. The implantation of ink helped in observing the damage zones. At first glance through the microscope, the coloration makes the tracks stand out right away. This coloration is helpful, from the start, in the morphological study of the tracks (size, area, orientation, shape, perimeter). This operation is advantageous in distinguishing the alpha particle tracks from stains or scratches. Thus, the routine counting of the tracks is more easily performed. Consequently, this procedure allowed us: to decrease significantly the standard deviation of the approximate total of the parameters given from the image analysis system (Olympus CUE2); to envision the possibility of reasonably decreasing the etching time in order to limit the loss of information caused by the destruction of the CR-39 during chemical etching and to use a weaker enlarging lens in order to cover a larger fi...

  16. Single-Photon Tracking for High-Speed Vision

    Directory of Open Access Journals (Sweden)

    Istvan Gyongy

    2018-01-01

    Full Text Available Quanta Imager Sensors provide photon detections at high frame rates, with negligible read-out noise, making them ideal for high-speed optical tracking. At the basic level of bit-planes or binary maps of photon detections, objects may present limited detail. However, through motion estimation and spatial reassignment of photon detections, the objects can be reconstructed with minimal motion artefacts. We here present the first demonstration of high-speed two-dimensional (2D tracking and reconstruction of rigid, planar objects with a Quanta Image Sensor, including a demonstration of depth-resolved tracking.

  17. Effect of Ce and Cu co-doping on the structural, morphological, and optical properties of ZnO nanocrystals and first principle investigation of their stability and magnetic properties

    Science.gov (United States)

    Mary, J. Arul; Vijaya, J. Judith; Bououdina, M.; Kennedy, L. John; Dai, J. H.; Song, Y.

    2015-02-01

    Ce, Cu co-doped ZnO (Zn1-2xCexCuxO: x=0.00, 0.01, 0.02, 0.03, 0.04 and 0.05) nanocrystals were synthesized by a microwave combustion method. These nanocrystals were investigated by using X-ray diffraction (XRD), UV-visible diffuse reflectance spectroscopy (DRS), scanning electron microscopy (SEM), and vibrating sample magnetometer (VSM). The stability and magnetic properties of Ce and Cu co-doped ZnO were probed by first principle calculations. XRD results revealed that all the compositions are single crystalline. hexagonal wurtzite structure. The optical band gap of pure ZnO was found to be 3.22 eV, and it decreased from 3.15 to 3.10 eV with an increase in the concentration of Cu and Ce content. The morphologies of Ce and Cu co-doped ZnO samples confirmed the formation of nanocrystals with an average grain size ranging from 70 to 150 nm. The magnetization measurement results affirmed the antiferro and ferromagnetic state for Ce and Cu co-doped ZnO samples and this is in agreement with the first principles theoretical calculations.

  18. Free space optical communication

    CERN Document Server

    Kaushal, Hemani; Kar, Subrat

    2017-01-01

    This book provides an in-depth understanding of free space optical (FSO) communication with a particular emphasis on optical beam propagation through atmospheric turbulence. The book is structured in such a way that it provides a basic framework for the beginners and also gives a concise description from a designer’s perspective. The book provides an exposure to FSO technology, fundamental limitations, design methodologies, system trade-offs, acquisition, tracking and pointing (ATP) techniques and link-feasibility analysis. The contents of this book will be of interest to professionals and researchers alike. The book may also be used as a textbook for engineering coursework and professional training.

  19. Large angle tracking and high discriminating tracking in nuclear emulsion

    International Nuclear Information System (INIS)

    Matsuo, Tomokazu; Shibuya, Hiroshi; Ogawa, Satoru; Fukuda, Tsutomu; Mikado, Shoji

    2015-01-01

    Nuclear emulsion is a high resolution and re-analyzable detector. Conventional “Track Selector” which have angle acceptance |tan θ|<0.6 are widely used to find tracks in emulsion. We made a new track selector “Fine Track Selector” (FTS) which has large angle acceptance and high discriminating ability. The FTS reduces fake tracks using new algorithms, navigation etc. FTS also keeps finding efficiency of tracks around 90% in an angle range of |tan θ| < 3.5. FTS was applied to the τ candidate in OPERA and no additional tracks found. FTS will be useful to our new J-PARC emulsion experiment.

  20. Deep space optical communication via relay satellite

    Science.gov (United States)

    Dolinar, S.; Vilnrotter, V.; Gagliardi, R.

    1981-01-01

    The application of optical communications for a deep space link via an earth-orbiting relay satellite is discussed. The system uses optical frequencies for the free-space channel and RF links for atmospheric transmission. The relay satellite is in geostationary orbit and contains the optics necessary for data processing and formatting. It returns the data to earth through the RF terrestrial link and also transmits an optical beacon to the satellite for spacecraft return pointing and for the alignment of the transmitting optics. Future work will turn to modulation and coding, pointing and tracking, and optical-RF interfacing.

  1. Tuned optical cavity magnetometer

    Science.gov (United States)

    Okandan, Murat; Schwindt, Peter

    2010-11-02

    An atomic magnetometer is disclosed which utilizes an optical cavity formed from a grating and a mirror, with a vapor cell containing an alkali metal vapor located inside the optical cavity. Lasers are used to magnetically polarize the alkali metal vapor and to probe the vapor and generate a diffracted laser beam which can be used to sense a magnetic field. Electrostatic actuators can be used in the magnetometer for positioning of the mirror, or for modulation thereof. Another optical cavity can also be formed from the mirror and a second grating for sensing, adjusting, or stabilizing the position of the mirror.

  2. Performance Evaluation of Dual-axis Tracking System of Parabolic Trough Solar Collector

    Science.gov (United States)

    Ullah, Fahim; Min, Kang

    2018-01-01

    A parabolic trough solar collector with the concentration ratio of 24 was developed in the College of Engineering; Nanjing Agricultural University, China with the using of the TracePro software an optical model built. Effects of single-axis and dual-axis tracking modes, azimuth and elevating angle tracking errors on the optical performance were investigated and the thermal performance of the solar collector was experimentally measured. The results showed that the optical efficiency of the dual-axis tracking was 0.813% and its year average value was 14.3% and 40.9% higher than that of the eat-west tracking mode and north-south tracking mode respectively. Further, form the results of the experiment, it was concluded that the optical efficiency was affected significantly by the elevation angle tracking errors which should be kept below 0.6o. High optical efficiency could be attained by using dual-tracking mode even though the tracking precision of one axis was degraded. The real-time instantaneous thermal efficiency of the collector reached to 0.775%. In addition, the linearity of the normalized efficiency was favorable. The curve of the calculated thermal efficiency agreed well with the normalized instantaneous efficiency curve derived from the experimental data and the maximum difference between them was 10.3%. This type of solar collector should be applied in middle-scale thermal collection systems.

  3. Self-trapped optical beams: Spatial solitons

    Indian Academy of Sciences (India)

    as

    tons, including the soliton stability in non-Kerr media, the instability-induced soliton dynamics, and collision of solitary ... suggested as a way to stabilize such a catastrophic self-focusing and produce stable solitary waves of ...... cations of spatial optical solitons towards creating a novel generation of nonlinear optical devices ...

  4. Adaptive DFT-Based Interferometer Fringe Tracking

    Directory of Open Access Journals (Sweden)

    Pedretti Ettore

    2005-01-01

    Full Text Available An automatic interferometer fringe tracking system has been developed, implemented, and tested at the Infrared Optical Telescope Array (IOTA Observatory at Mount Hopkins, Arizona. The system can minimize the optical path differences (OPDs for all three baselines of the Michelson stellar interferometer at IOTA. Based on sliding window discrete Fourier-transform (DFT calculations that were optimized for computational efficiency and robustness to atmospheric disturbances, the algorithm has also been tested extensively on offline data. Implemented in ANSI C on the 266 MHz PowerPC processor running the VxWorks real-time operating system, the algorithm runs in approximately milliseconds per scan (including all three interferograms, using the science camera and piezo scanners to measure and correct the OPDs. The adaptive DFT-based tracking algorithm should be applicable to other systems where there is a need to detect or track a signal with an approximately constant-frequency carrier pulse. One example of such an application might be to the field of thin-film measurement by ellipsometry, using a broadband light source and a Fourier-transform spectrometer to detect the resulting fringe patterns.

  5. Emissions Control in Swirl-Stabilized Combustors

    National Research Council Canada - National Science Library

    Hanson, Ronald K

    2006-01-01

    ...) fabricate a swirl-stabilized gas and liquid fuel burner with optical access to enable diagnostic development that mimics the atmospheric pressure performance of the University of Cincinnati facility, and 4...

  6. Clean tracks for ATLAS

    CERN Multimedia

    2006-01-01

    First cosmic ray tracks in the integrated ATLAS barrel SCT and TRT tracking detectors. A snap-shot of a cosmic ray event seen in the different layers of both the SCT and TRT detectors. The ATLAS Inner Detector Integration Team celebrated a major success recently, when clean tracks of cosmic rays were detected in the completed semiconductor tracker (SCT) and transition radiation tracker (TRT) barrels. These tracking tests come just months after the successful insertion of the SCT into the TRT (See Bulletin 09/2006). The cosmic ray test is important for the experiment because, after 15 years of hard work, it is the last test performed on the fully assembled barrel before lowering it into the ATLAS cavern. The two trackers work together to provide millions of channels so that particles' tracks can be identified and measured with great accuracy. According to the team, the preliminary results were very encouraging. After first checks of noise levels in the final detectors, a critical goal was to study their re...

  7. Small Orbital Stereo Tracking Camera Technology Development

    Science.gov (United States)

    Gagliano, L.; Bryan, T.; MacLeod, T.

    On-Orbit Small Debris Tracking and Characterization is a technical gap in the current National Space Situational Awareness necessary to safeguard orbital assets and crew. This poses a major risk of MOD damage to ISS and Exploration vehicles. In 2015 this technology was added to NASAs Office of Chief Technologist roadmap. For missions flying in or assembled in or staging from LEO, the physical threat to vehicle and crew is needed in order to properly design the proper level of MOD impact shielding and proper mission design restrictions. Need to verify debris flux and size population versus ground RADAR tracking. Use of ISS for In-Situ Orbital Debris Tracking development provides attitude, power, data and orbital access without a dedicated spacecraft or restricted operations on-board a host vehicle as a secondary payload. Sensor Applicable to in-situ measuring orbital debris in flux and population in other orbits or on other vehicles. Could enhance safety on and around ISS. Some technologies extensible to monitoring of extraterrestrial debris as well To help accomplish this, new technologies must be developed quickly. The Small Orbital Stereo Tracking Camera is one such up and coming technology. It consists of flying a pair of intensified megapixel telephoto cameras to evaluate Orbital Debris (OD) monitoring in proximity of International Space Station. It will demonstrate on-orbit optical tracking (in situ) of various sized objects versus ground RADAR tracking and small OD models. The cameras are based on Flight Proven Advanced Video Guidance Sensor pixel to spot algorithms (Orbital Express) and military targeting cameras. And by using twin cameras we can provide Stereo images for ranging & mission redundancy. When pointed into the orbital velocity vector (RAM), objects approaching or near the stereo camera set can be differentiated from the stars moving upward in background.

  8. Small Business Innovations (Fiber Optics)

    Science.gov (United States)

    1991-01-01

    Foster-Miller, Inc. Waltham, MA developed the In-Situ Fiber Optic Polymer Reaction Monitor which could lead to higher yields and lower costs in complex composite manufacturing. The monitor, developed under a Small Business Innovation Research (SBIR) contract with Langley Research Center, uses an infrared, fiber optic sensor to track the molecular vibrational characteristics of a composite part while it is being cured. It is the first analytical system capable of directly measuring the chemistry of advanced composite materials.

  9. Deep 6-DOF Tracking.

    Science.gov (United States)

    Garon, Mathieu; Lalonde, Jean-Francois

    2017-11-01

    We present a temporal 6-DOF tracking method which leverages deep learning to achieve state-of-the-art performance on challenging datasets of real world capture. Our method is both more accurate and more robust to occlusions than the existing best performing approaches while maintaining real-time performance. To assess its efficacy, we evaluate our approach on several challenging RGBD sequences of real objects in a variety of conditions. Notably, we systematically evaluate robustness to occlusions through a series of sequences where the object to be tracked is increasingly occluded. Finally, our approach is purely data-driven and does not require any hand-designed features: robust tracking is automatically learned from data.

  10. EYE GAZE TRACKING

    DEFF Research Database (Denmark)

    2017-01-01

    This invention relates to a method of performing eye gaze tracking of at least one eye of a user, by determining the position of the center of the eye, said method comprising the steps of: detecting the position of at least three reflections on said eye, transforming said positions to spanning...... a normalized coordinate system spanning a frame of reference, wherein said transformation is performed based on a bilinear transformation or a non linear transformation e.g. a möbius transformation or a homographic transformation, detecting the position of said center of the eye relative to the position...... of said reflections and transforming this position to said normalized coordinate system, tracking the eye gaze by tracking the movement of said eye in said normalized coordinate system. Thereby calibration of a camera, such as knowledge of the exact position and zoom level of the camera, is avoided...

  11. Negotiating Family Tracking

    DEFF Research Database (Denmark)

    Albrechtslund, Anders; Bøge, Ask Risom; Sonne Damkjær, Maja

    This presentation explores the question: What motivates the use of tracking technologies in families, and how does the use transform the relations between parent and child? The purpose is to investigate why tracking technologies are used in families and how these technologies potentially change...... the relation between parents and children. The use of tracking technologies in families implicate negotiations about the boundaries of trust and intimacy in parent-child relations which can lead to strategies of resistance or modification (Fotel and Thomsen, 2004; Rooney, 2010; Steeves and Jones, 2010......). In the presentation, we report from a qualitative study that focuses on intergenerational relations. The study draws on empirical data from workshops with Danish families as well as individual and group interviews. We aim to gain insights about the sharing habits and negotiations in intimate family relations...

  12. Stability diagram of colliding beams

    CERN Document Server

    Buffat, X; Mounet, N; Pieloni, T

    2014-01-01

    The effect of the beam-beam interactions on the stability of impedance mode is discussed. The detuning is evaluated by the means of single particle tracking in arbitrarily complex collision configurations, including lattice non-linearities, and used to numerically evaluate the dispersion integral. This approach also allows the effect of non-Gaussian distributions to be considered. Distributions modified by the action of external noise are discussed.

  13. Exponentially Stabilizing Robot Control Laws

    Science.gov (United States)

    Wen, John T.; Bayard, David S.

    1990-01-01

    New class of exponentially stabilizing laws for joint-level control of robotic manipulators introduced. In case of set-point control, approach offers simplicity of proportion/derivative control architecture. In case of tracking control, approach provides several important alternatives to completed-torque method, as far as computational requirements and convergence. New control laws modified in simple fashion to obtain asymptotically stable adaptive control, when robot model and/or payload mass properties unknown.

  14. PRECISE HEAD TRACKING IN HEARING APPLICATIONS

    Directory of Open Access Journals (Sweden)

    A. M. Helle

    2015-05-01

    Full Text Available The paper gives an overview about two research projects, both dealing with optical head tracking in hearing applications. As part of the project “Development of a real-time low-cost tracking system for medical and audiological problems (ELCoT” a cost-effective single camera 3D tracking system has been developed which enables the detection of arm and head movements of human patients. Amongst others, the measuring system is designed for a new hearing test (based on the “Mainzer Kindertisch”, which analyzes the directional hearing capabilities of children in cooperation with the research project ERKI (Evaluation of acoustic sound source localization for children. As part of the research project framework “Hearing in everyday life (HALLO” a stereo tracking system is being used for analyzing the head movement of human patients during complex acoustic events. Together with the consideration of biosignals like skin conductance the speech comprehension and listening effort of persons with reduced hearing ability, especially in situations with background noise, is evaluated. For both projects the system design, accuracy aspects and results of practical tests are discussed.

  15. Precise Head Tracking in Hearing Applications

    Science.gov (United States)

    Helle, A. M.; Pilinski, J.; Luhmann, T.

    2015-05-01

    The paper gives an overview about two research projects, both dealing with optical head tracking in hearing applications. As part of the project "Development of a real-time low-cost tracking system for medical and audiological problems (ELCoT)" a cost-effective single camera 3D tracking system has been developed which enables the detection of arm and head movements of human patients. Amongst others, the measuring system is designed for a new hearing test (based on the "Mainzer Kindertisch"), which analyzes the directional hearing capabilities of children in cooperation with the research project ERKI (Evaluation of acoustic sound source localization for children). As part of the research project framework "Hearing in everyday life (HALLO)" a stereo tracking system is being used for analyzing the head movement of human patients during complex acoustic events. Together with the consideration of biosignals like skin conductance the speech comprehension and listening effort of persons with reduced hearing ability, especially in situations with background noise, is evaluated. For both projects the system design, accuracy aspects and results of practical tests are discussed.

  16. Search for disappearing tracks

    CERN Document Server

    INSPIRE-00024550

    2015-01-01

    We present a search for long-lived charged particles that decay within the CMS detector and produce the signature of a disappearing track. Disappearing tracks are identified as those with little or no associated calorimeter energy deposits and with missing hits in the outer layers of the tracker. The search uses proton-proton collision data recorded at $\\sqrt{s} = 8$ TeV that corresponds to an integrated luminosity of 19.5 fb$^{-1}$. The results of the search are interpreted in the context of the anomaly-mediated supersymmetry breaking model and in terms of the phenomenological MSSM.

  17. Tracking Your Development

    CERN Document Server

    Hennum, Kelly M

    2011-01-01

    This book provides you with the means to set development goals and to track your progress on achieving them. It can help you efficiently gather and make sense of information about your progress and avoid common pitfalls that can block your development. Tracking your development can be captures in a few steps: articulating your goal, creating an action plan, gathering information about your behavior, indentifying barriers and support, and revising your action plan. Taking these steps will greatly increase the likelihood of achieving your goals.

  18. Spin tracking in RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Luccio, A.U. [Brookhaven National Lab., Upton, NY (United States); Katayama, T. [Univ. of Tokyo (Japan); Wu, H. [Riken Inst., Tokyo (Japan)

    1997-07-01

    In the acceleration of polarized protons in RHIC many spin depolarizing resonances are encountered. Helical Siberian snakes will be used to overcome depolarizing effects. The behavior of polarization can be studied by numerical tracking in a model accelerator. That allows one to check the strength of the resonances, to study the effect of snakes, to find safe lattice tune regions, and finally to study the operation of special devices like spin flippers. In this paper the authors describe numerical spin tracking. Results show that, for the design corrected distorted orbit and the design beam emittance, the polarization of the beam will be preserved in the whole range of proton energies in RHIC.

  19. Object Tracking with RFID

    Science.gov (United States)

    Yamada, Kou; Uchida, Seiichi; Taniguchi, Rin-Ichiro

    This paper reports a new method for visual tracking of humans using active RFID technology. Previous studies were based on the assumption that the radio intensity from an RFID tag will be linearly proportional to the distance between the tag and the antenna or will remain unchanged; however, in reality, the intensity fluctuates significantly and changes drastically with a small change in the environment. The proposed method helps to overcome this problem by using only accurate binary information that reveals whether the target person is close to the antenna. Several experimental results have shown that the information from the RFID tag was useful for reliable tracking of humans.

  20. Military tracked vehicles

    CERN Document Server

    Hansen, Grace

    2016-01-01

    Tracked vehicles are important to militaries around the world, since they're usually supporting and carrying ground troops. Readers will learn what tracks are and why they're necessary for large, frontline battle tanks like the Bradley M2 Abrams. Big full-bleed photographs, new glossary terms, and a close up look at a vehicle will keep readers wanting more! Aligned to Common Core Standards and correlated to state standards. Abdo Kids Jumbo is an imprint of Abdo Kids, a division of ABDO.