WorldWideScience

Sample records for stability test results

  1. Dynamic stability test results on an 0.024 scale B-1 air vehicle

    Science.gov (United States)

    Beeman, R. R.

    1972-01-01

    Dynamic longitudinal and lateral-directional stability characteristics of the B-1 air vehicle were investigated in three wind tunnels at the Langley Research Center. The main rotary derivatives were obtained for an angle of attack range of -3 degrees to +16 degrees for a Mach number range of 0.2 to 2.16. Damping in roll data could not be obtained at the supersonic Mach numbers. The Langley 7 x 10 foot high speed tunnel, the 8 foot transonic pressure tunnel, and the 4 foot Unitary Plan wind tunnel were the test sites. An 0.024 scale light-weight model was used on a forced oscillation type balance. Test Reynolds number varied from 474,000/ft to 1,550,000/ft. through the Mach number range tested. The results showed that the dynamic stability characteristics of the model in pitch and roll were generally satisfactory up to an angle attack of about +6 degrees. In the wing sweep range from 15 to 25 degrees the positive damping levels in roll deteriorated rapidly above +2 degrees angle of attack. This reduction in roll damping is believed to be due to the onset of separation over the wing as stall is approached.

  2. Montmorillonite stability - experimental results

    International Nuclear Information System (INIS)

    Karnland, Ola; Birgersson, Martin; Olsson, Siv

    2012-01-01

    Document available in extended abstract form only. Several repository concepts for spent nuclear fuel comprise a bentonite buffer which encloses the fuel containers. The function of this bentonite buffer is critically dependent on the properties of the swelling mineral in the bentonite, which typically is montmorillonite in commercial high quality bentonites. The physical and chemical properties of the montmorillonite in bentonites have consequently been studied in various types of analyses in several countries, and the results have been the basis for the design of the bentonite buffer with respect to size, degree of compaction etc (SKB TR-10-47). Significant changes in the montmorillonite structure with time may change the properties of the bentonite buffer and jeopardize the isolating function. In nature, illite is the most common alteration product from montmorillonite, and a 50% alteration reduces, for instance, the swelling pressure by one order of magnitude. Fortunately, the process is very slow at typical repository temperatures, and also in the perspective of repository life-time no significant alteration is expected according to the available kinetic models. The models are, however, based on laboratory batch experiments performed at temperatures, which by necessity are much higher than what is planned for in a repository. Alternatively, the models are based on natural montmorillonite-to-illite alteration in e.g. deep sediments. In both cases there are divergences from repository conditions which limit the arguments for the bentonite buffer stability. The mechanism by which the montmorillonite-to-illite reaction takes place is not fully understood, but the overall process may be represented by the following schematic reaction: Na + montmorillonite + K + + Al 3+ → illite + SiO 2 + Na + . Aluminum may be supplied from the bentonite itself, but potassium has to be transported to the buffer from an external source in order to give a significant alteration in

  3. Results of Long-Term Stability Tests Performed for the Eutectics Co-C and Pt-C

    Science.gov (United States)

    Wang, T.; Bai, C.; Dong, W.; Yuan, Z.; Bloembergen, P.; Liu, F.

    2011-08-01

    The stability of the Co-C and Pt-C eutectic fixed points is investigated in this article. Six cells were employed for the testing. Two existing cells, a Co-C cell with a C/C sheet incorporated and a Pt-C cell equipped with a graphite sleeve that had been previously aged, were studied to determine the presence of anomalous drifts or degrading robustness that may possibly appear when the testing period is extended. The stability of four cells of a new design, a Co-C cell and three Pt-C cells, which were constructed in a hybrid manner, to include a sleeve, foil lining, and two of them with a cavity support, were likewise tested. Results show that different designs of Pt-C cells can exhibit good stability. However, for Co-C cells, the cavity rift remains a problem. The possible reasons for this rift and methods for increasing cell life are discussed.

  4. Results of a Saxitoxin Proficiency Test Including Characterization of Reference Material and Stability Studies

    Directory of Open Access Journals (Sweden)

    Kirsi Harju

    2015-11-01

    Full Text Available A saxitoxin (STX proficiency test (PT was organized as part of the Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk (EQuATox project. The aim of this PT was to provide an evaluation of existing methods and the European laboratories’ capabilities for the analysis of STX and some of its analogues in real samples. Homogenized mussel material and algal cell materials containing paralytic shellfish poisoning (PSP toxins were produced as reference sample matrices. The reference material was characterized using various analytical methods. Acidified algal extract samples at two concentration levels were prepared from a bulk culture of PSP toxins producing dinoflagellate Alexandrium ostenfeldii. The homogeneity and stability of the prepared PT samples were studied and found to be fit-for-purpose. Thereafter, eight STX PT samples were sent to ten participating laboratories from eight countries. The PT offered the participating laboratories the possibility to assess their performance regarding the qualitative and quantitative detection of PSP toxins. Various techniques such as official Association of Official Analytical Chemists (AOAC methods, immunoassays, and liquid chromatography-mass spectrometry were used for sample analyses.

  5. Stability and control flight test results of the space transportation system's orbiter

    Science.gov (United States)

    Culp, M. A.; Cooke, D. R.

    1982-01-01

    Flight testing of the Space Shuttle Orbiter is in progress and current results of the post-flight aerodynamic analyses are discussed. The purpose of these analyses is to reduce the pre-flight aerodynamic uncertainties, thereby leading to operational certification of the Orbiter flight envelope relative to the integrated airframe and flight control system. Primary data reduction is accomplished with a well documented maximum likelihood system identification techniques.

  6. Sludge stabilization operability test report

    International Nuclear Information System (INIS)

    Lewis, W.S.

    1994-01-01

    Document provides the results of the Operability Test Procedure performed to test the operability of the HC-21C thermal stabilization process for sludge. The OTP assured all equipment functioned properly and established the baseline temperature profile for glovebox HC-21C

  7. Cholesterol testing and results

    Science.gov (United States)

    Cholesterol test results; LDL test results; VLDL test results; HDL test results; Coronary risk profile results; Hyperlipidemia-results; Lipid disorder test results; Heart disease - cholesterol results

  8. Flight Test Results from the NF-15B Intelligent Flight Control System (IFCS) Project with Adaptation to a Simulated Stabilator Failure

    Science.gov (United States)

    Bosworth, John T.; Williams-Hayes, Peggy S.

    2010-01-01

    Adaptive flight control systems have the potential to be more resilient to extreme changes in airplane behavior. Extreme changes could be a result of a system failure or of damage to the airplane. A direct adaptive neural-network-based flight control system was developed for the National Aeronautics and Space Administration NF-15B Intelligent Flight Control System airplane and subjected to an inflight simulation of a failed (frozen) (unmovable) stabilator. Formation flight handling qualities evaluations were performed with and without neural network adaptation. The results of these flight tests are presented. Comparison with simulation predictions and analysis of the performance of the adaptation system are discussed. The performance of the adaptation system is assessed in terms of its ability to decouple the roll and pitch response and reestablish good onboard model tracking. Flight evaluation with the simulated stabilator failure and adaptation engaged showed that there was generally improvement in the pitch response; however, a tendency for roll pilot-induced oscillation was experienced. A detailed discussion of the cause of the mixed results is presented.

  9. Undulator Transportation Test Results

    International Nuclear Information System (INIS)

    Wolf, Zachary

    2010-01-01

    A test was performed to determine whether transporting and handling the undulators makes any changes to their properties. This note documents the test. No significant changes to the test undulator were observed. After the LCLS undulators are tuned and fiducialized in the Magnetic Measurement Facility (MMF), they must be transported to storage buildings and transported to the tunnel. It has been established that the undulators are sensitive to temperature. We wish to know whether the undulators are also sensitive to the vibrations and shocks of transportation. To study this issue, we performed a test in which an undulator was measured in the MMF, transported to the tunnel, brought back to the MMF, and re-measured. This note documents the test and the results.

  10. Climax granite test results

    Energy Technology Data Exchange (ETDEWEB)

    Ramspott, L.D.

    1980-01-15

    The Lawrence Livermore Laboratory (LLL), as part of the Nevada Nuclear Waste Storage Investigations (NNWSI) program, is carrying out in situ rock mechanics testing in the Climax granitic stock at the Nevada Test Site (NTS). This summary addresses only those field data taken to date that address thermomechanical modeling for a hard-rock repository. The results to be discussed include thermal measurements in a heater test that was conducted from October 1977 through July 1978, and stress and displacement measurements made during and after excavation of the canister storage drift for the Spent Fuel Test (SFT) in the Climax granite. Associated laboratory and field measurements are summarized. The rock temperature for a given applied heat load at a point in time and space can be adequately modeled with simple analytic calculations involving superposition and integration of numerous point source solutions. The input, for locations beyond about a meter from the source, can be a constant thermal conductivity and diffusivity. The value of thermal conductivity required to match the field data is as much as 25% different from laboratory-measured values. Therefore, unless we come to understand the mechanisms for this difference, a simple in situ test will be required to obtain a value for final repository design. Some sensitivity calculations have shown that the temperature field is about ten times more sensitive to conductivity than to diffusivity under the test conditions. The orthogonal array was designed to detect anisotropy. After considering all error sources, anisotropic efforts in the thermal field were less than 5 to 10%.

  11. Legacy Compliance Final Report: Results of the Navy/Encapo Soil Stabilization Study at the Nevada Test Site, Nye County, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Desotell, Lloyd; Anderson, David; Rawlinson, Stuart; Hudson, David; Yucel, Vefa

    2008-03-01

    sediment loads as compared to untreated plots for the first two rounds of simulations. These data indicate the treatment caused the treated surfaces to repel more of the simulated rainfall than the untreated plots but did not increase the cohesion between soil particles to resist soil particle detachment and transport with the runoff water. Am-241 concentration in collected sediments varied as a function of proximity to the safety test locations, not as a function of surface treatment. The results from field testing the Encapco emulsion indicate it is not a viable long-term option for the stabilization of radionuclide impacted surface soils at the Nevada Test Site in its current formulation. Dust suppression studies conducted by Etyemezian et al. (2006) at an uncontaminated location near the SMOKY site indicate the emulsion significantly reduced dust emissions for at least four months post application, indicating the emulsion may be useful for short-term applications.

  12. Dissociated methanol test results

    Energy Technology Data Exchange (ETDEWEB)

    Finegold, J.G.; McKinnon, J.T.

    1982-04-01

    The design and testing of an automotive fuel system that provides hydrogen-rich gases to an internal combustion engine by catalytically cracking, or dissociating, methanol on board the vehicle is described. The vaporization and dissociation of methanol absorb heat from the engine exhaust and increase the lower heating value of the fuel by approximately 22%. In addition, raising the compression ratio and burning with excess air increase the engine thermal efficiency. Engine dynamometer test results with dissociated methanol demonstrated improvement in brake thermal efficiency compared to gasoline from 30% to 100% depending on engine speed and torque. Lower speeds and torques produce the largest improvements. Maps of exhaust temperature and exhaust heat content are presented. The exhaust temperature is almost always high enough for dissociation to occur, but at lower power outputs, there is only enough exhaust energy for partial dissociation of the methanol.

  13. Some results on stability of difference systems

    Directory of Open Access Journals (Sweden)

    Xiao-Song Yang

    2002-01-01

    Full Text Available This paper presents some new results on existence and stability of equilibrium or periodic points for difference systems. First sufficient conditions of existence of asymptotically stable equilibrium point as well as the asymptotic stability of given equilibrium point are given for second order or delay difference systems. Then some similar results on existence of asymptotically stable periodic (equilibrium points to general difference systems are presented.

  14. 21 CFR 211.166 - Stability testing.

    Science.gov (United States)

    2010-04-01

    ... expiration dates provided full shelf life studies are not available and are being conducted. Where data from... shelf life studies, there must be stability studies conducted, including drug product testing at... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Stability testing. 211.166 Section 211.166 Food...

  15. Liberalism, efficiency, and stability : Some possibility results

    NARCIS (Netherlands)

    van Hees, M

    1999-01-01

    Drawing on the game-theoretic analysis of rights, this paper re-examines the relation between liberal principles of decision making, on the one hand, and demands for stability and efficiency, on the other. Two possibility results are obtained. First, rights assignments in which individuals enjoy

  16. Liberalism, Efficiency, and Stability: Some Possibility Results

    NARCIS (Netherlands)

    Van Hees, Martin

    1999-01-01

    Drawing on the game-theoretic analysis of rights, this paper re-examines the relation between liberal principles of decision making, on the one hand, and demands for stability and efficiency, on the other. Two possibility results are obtained. First, rights assignments in which individuals enjoy

  17. Formulation and stability testing of photolabile drugs.

    Science.gov (United States)

    Tønnesen, H H

    2001-08-28

    Exposure of a drug to irradiation can influence the stability of the formulation, leading to changes in the physicochemical properties of the product. The influence of excipients of frequently used stabilizers is often difficult to predict and, therefore, stability testing of the final preparation is important. The selection of a protective packaging must be based on knowledge about the wavelength causing the instability. Details on drug photoreactivity will also be helpful in order to minimize side-effects and/or optimize drug targeting by developing photoresponsive drug delivery systems. This review focuses on practical problems related to formulation and stability testing of photolabile drugs.

  18. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  19. Pressure locking test results

    International Nuclear Information System (INIS)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D.

    1996-01-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, open-quotes Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.close quotes Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; we will publish the results of our thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions

  20. Pressure locking test results

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)] [and others

    1996-12-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.{close_quotes} Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; the authors will publish the results of their thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions.

  1. Stability Analysis of a High-Speed Seal Test Rotor With Marginal and Extended Squeeze-Film Dampers: Theoretical and Experimental Results

    Science.gov (United States)

    Proctor, Margaret P.; Gunter, Edgar J.

    2007-01-01

    A case study of a high-speed seal test rotor shows how rotor dynamic analysis can be used to diagnose the source of high vibrations and evaluate a proposed remedy. Experimental results are compared with the synchronous and non-synchronous whirl response analysis of a double overhung, high-speed seal test rotor with ball bearings supported in 5.84- and 12.7-mm-long, un-centered squeeze-film oil dampers. Test performance with the original damper of length 5.84 mm was marginal. Non-synchronous whirling occurred at the overhung seal test disk and there was a high amplitude synchronous response near the drive spline above 32,000 rpm. Nonlinear synchronous unbalance and time transient whirl studies were conducted on the seal test rotor with the original and extended damper lengths. With the original damper design, the nonlinear synchronous response showed that unbalance could cause damper lockup at 33,000 rpm. Alford cross-coupling forces were also included at the overhung seal test disk for the whirl analysis. Sub-synchronous whirling at the seal test disk was observed in the nonlinear time transient analysis. With the extended damper length of 12.7 mm, the sub-synchronous motion was eliminated and the rotor unbalance response was acceptable to 45,000 rpm with moderate rotor unbalance. Seal test rotor orbits and vibration levels with the extended squeeze film dampers showed smooth operation to 40,444 rpm.

  2. Atomic Stability as Result of Electrodynamic Stability Condition

    Science.gov (United States)

    Zheng-Johansson, Jx; Johansson, P.-I.

    2006-03-01

    According to [1] an electron e^- is formed of an oscillatory massless charge -e in general also traveling at velocity v, and the resulting electromagnetic waves of angular frequency ĵ, j= and for generated in +v and -v directions. The wave energy √̂̂ equals the charge oscillation energy ɛq (with the v=0 portion) endowed at the charge's creation; ɛq/c^2 gives the electron mass me, c the wave speed. For an atomic orbiting electron, the charge's v motion is along a circular (or projected-elliptic) orbit l of radius r; so are its waves. (a) The waves meet in each loop with the charge, are absorbed a portion by it and reemitted, repeatedly, and thereby retained to it; the vacuum, having no lower energy levels for the charge to decay to except in a pair annihilation, is essentially a non-dissipative medium. (b) The two waves, being Doppler-differentiated for the moving source, meet each other over the loops and superpose into a beat, or de Broglie phase wave ψ. ψ =C e^i(kdl-φT) is a maximum if 2πrn= nλdn, n integer, λd=2πkd=(cv)λ the de Broglie wavelength and λ=2 πcφ, and accordingly yields a stable state. The corresponding overall eigen solutions are exactly equivalent with the QM results. The classical electrodynamic stability conditions (a)-(b) entail the stability of the atomic system. [1] JX Zheng-Johansson & P-I Johansson, Unification of Classical, Quantum and Relativistic Mechanics and the Four Forces, Fwd Prof R Lundin, Nova Science, NY, 2005; see also B40.00003, this meeting.

  3. Fault Tolerant Control: A Simultaneous Stabilization Result

    DEFF Research Database (Denmark)

    Stoustrup, Jakob; Blondel, V.D.

    2004-01-01

    This paper discusses the problem of designing fault tolerant compensators that stabilize a given system both in the nominal situation, as well as in the situation where one of the sensors or one of the actuators has failed. It is shown that such compensators always exist, provided that the system...... is detectable from each output and that it is stabilizable. The proof of this result is constructive, and a worked example shows how to design a fault tolerant compensator for a simple, yet challeging system. A family of second order systems is described that requires fault tolerant compensators of arbitrarily...

  4. Automation for a base station stability testing

    OpenAIRE

    Punnek, Elvis

    2016-01-01

    This Batchelor’s thesis was commissioned by Oy LM Ericsson Ab Oulu. The aim of it was to help to investigate and create a test automation solution for the stability testing of the LTE base station. The main objective was to create a test automation for a predefined test set. This test automation solution had to be created for specific environments and equipment. This work included creating the automation for the test cases and putting them to daily test automation jobs. The key factor...

  5. MITG test procedure and results

    International Nuclear Information System (INIS)

    Eck, M.E.; Mukunda, M.

    1983-01-01

    Elements and modules for Radioisotope Thermoelectric Generator have been performance tested since the inception of the RTG program. These test articles seldom resembled flight hardware and often lacked adequate diagnostic instrumentation. Because of this, performance problems were not identified in the early stage of program development. The lack of test data in an unexpected area often hampered the development of a problem solution. A procedure for conducting the MITG Test was developed in an effort to obtain data in a systematic, unambiguous manner. This procedure required the development of extensive data acquisition software and test automation. The development of a facility to implement the test procedure, the facility hardware and software requirements, and the results of the MITG testing are the subject of this paper

  6. Test Bench Development for Femur Stability Assessment

    Directory of Open Access Journals (Sweden)

    Samuel SANCHEZ-CABALLERO

    2015-01-01

    Full Text Available This paper shows the design and development of a test bench for humanfemurs. The main uses of this test bench will run from artificial femurs comparisonwith real femurs, to join stability assessment after bone a fracture repair. Amongthis uses is specially designed for condylar fractures testing. The test bench isdeveloped from a self-made existing tensile/compression testing machine. Thedesign procedure is supported by a literature review about the bone mechanicalbehavior and composition generally and the knee joint performance and repairparticularly. On the basis of this review, the machine was designed to simulate theadduction and abduction movements of the joint. The magnitudes to be measuredare: the compression force, the bone displacement (vertical and the knee jointrotation

  7. Mobile evaporator corrosion test results

    International Nuclear Information System (INIS)

    Rozeveld, A.; Chamberlain, D.B.

    1997-05-01

    Laboratory corrosion tests were conducted on eight candidates to select a durable and cost-effective alloy for use in mobile evaporators to process radioactive waste solutions. Based on an extensive literature survey of corrosion data, three stainless steel alloys (304L, 316L, AL-6XN), four nickel-based alloys (825, 625, 690, G-30), and titanium were selected for testing. The corrosion tests included vapor phase, liquid junction (interface), liquid immersion, and crevice corrosion tests on plain and welded samples of candidate materials. Tests were conducted at 80 degrees C for 45 days in two different test solutions: a nitric acid solution. to simulate evaporator conditions during the processing of the cesium ion-exchange eluant and a highly alkaline sodium hydroxide solution to simulate the composition of Tank 241-AW-101 during evaporation. All of the alloys exhibited excellent corrosion resistance in the alkaline test solution. Corrosion rates were very low and localized corrosion was not observed. Results from the nitric acid tests showed that only 316L stainless steel did not meet our performance criteria. The 316L welded interface and crevice specimens had rates of 22.2 mpy and 21.8 mpy, respectively, which exceeds the maximum corrosion rate of 20 mpy. The other welded samples had about the same corrosion resistance as the plain samples. None of the welded samples showed preferential weld or heat-affected zone (HAZ) attack. Vapor corrosion was negligible for all alloys. All of the alloys except 316L exhibited either open-quotes satisfactoryclose quotes (2-20 mpy) or open-quotes excellentclose quotes (<2 mpy) corrosion resistance as defined by National Association of Corrosion Engineers. However, many of the alloys experienced intergranular corrosion in the nitric acid test solution, which could indicate a susceptibility to stress corrosion cracking (SCC) in this environment

  8. EFTF cobalt test assembly results

    International Nuclear Information System (INIS)

    Rawlins, J.A.; Wootan, D.W.; Carter, L.L.; Brager, H.R.; Schenter, R.E.

    1988-01-01

    A cobalt test assembly containing yttrium hydride pins for neutron moderation was irradiated in the Fast Flux Test Facility during Cycle 9A for 137.7 equivalent full power days at a power level fo 291 MW. The 36 test pins consisted of a batch of 32 pins containing cobalt metal to produce Co-60, and a set of 4 pins with europium oxide to produce Gd-153, a radioisotope used in detection of the bone disease Osteoporosis. Post-irradiation examination of the cobalt pins determined the Co-60 produced with an accuracy of about 5 %. The measured Co-60 spatially distributed concentrations were within 20 % of the calculated concentrations. The assembly average Co-60 measured activity was 4 % less than the calculated value. The europium oxide pins were gamma scanned for the europium isotopes Eu-152 and Eu-154 to an absolute accuracy of about 10 %. The measured europium radioisotpe anc Gd-153 concentrations were within 20 % of calculated values. In conclusion, the hydride assembly performed well and is an excellent vehicle for many Fast Flux Test Facility isotope production applications. The results also demonstrate that the calculational methods developed by the Westinghouse Hanford Company are very accurate. (author)

  9. Evaluating the RELM Test Results

    Directory of Open Access Journals (Sweden)

    Michael K. Sachs

    2012-01-01

    Full Text Available We consider implications of the Regional Earthquake Likelihood Models (RELM test results with regard to earthquake forecasting. Prospective forecasts were solicited for M≥4.95 earthquakes in California during the period 2006–2010. During this period 31 earthquakes occurred in the test region with M≥4.95. We consider five forecasts that were submitted for the test. We compare the forecasts utilizing forecast verification methodology developed in the atmospheric sciences, specifically for tornadoes. We utilize a “skill score” based on the forecast scores λfi of occurrence of the test earthquakes. A perfect forecast would have λfi=1, and a random (no skill forecast would have λfi=2.86×10-3. The best forecasts (largest value of λfi for the 31 earthquakes had values of λfi=1.24×10-1 to λfi=5.49×10-3. The best mean forecast for all earthquakes was λ̅f=2.84×10-2. The best forecasts are about an order of magnitude better than random forecasts. We discuss the earthquakes, the forecasts, and alternative methods of evaluation of the performance of RELM forecasts. We also discuss the relative merits of alarm-based versus probability-based forecasts.

  10. EO framing flight test results

    Science.gov (United States)

    Lareau, Andre G.

    1995-09-01

    Recon/Optical, Inc. (ROI) has pioneered the electro-optical (E-O) framing generation of sensors with the CA-260, a KS-87 form/fit camera with a wafer-scale focal plane array (FPA) containing a patented, on-chip, forward motion compensation (FMC) architecture. The technology has now matured to the state where production E-O framing cameras are form/fit replacing their former film counterparts. During this interim production phase, flight demonstrations and tests are continuing to prove that E-O framing produces high-quality imagery, is robust to various platforms and mission tactics, interoperable with existing and planned C3I architectures, affordable and available, and meets the war-fighters needs. This paper discusses flight test results of the CA-260 E-O framing sensor flown in the F-14A TARPS during September 1994. This demonstration provided some unique imagery permitting a comparison of low-light level, in-flight FMC-on versus FMC-off performance. A first-level comparison of the resulting imagery based upon predicted FMC performance and post- processing numerical analysis is presented. The results indicae that the patented FMC architecture performed as predicted, and that for low-light conditions resulting in limited SNR images, on-chip FMC can provide a significant image quality improvement over post- processing alternatives.

  11. RSG Deployment Case Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Owsley, Stanley L.; Dodson, Michael G.; Hatchell, Brian K.; Seim, Thomas A.; Alexander, David L.; Hawthorne, Woodrow T.

    2005-09-01

    The RSG deployment case design is centered on taking the RSG system and producing a transport case that houses the RSG in a safe and controlled manner for transport. The transport case was driven by two conflicting constraints, first that the case be as light as possible, and second that it meet a stringent list of Military Specified requirements. The design team worked to extract every bit of weight from the design while striving to meet the rigorous Mil-Spec constraints. In the end compromises were made primarily on the specification side to control the overall weight of the transport case. This report outlines the case testing results.

  12. ENRtool - BesTest results

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne

    2007-01-01

    Test af beregninger gennemført med ENRtool over for BesTest valideringen under klimatiske forhold for Denver, Colorado.......Test af beregninger gennemført med ENRtool over for BesTest valideringen under klimatiske forhold for Denver, Colorado....

  13. Surface stabilization and revegetation test plots

    International Nuclear Information System (INIS)

    Sackschewsky, M.R.; Kemp, C.J.; Hayward, W.M.

    1993-09-01

    Westinghouse Hanford Company Decommissioning and Decontamination Engineering Group and Environmental Technology and Assessment Groups are developing new technologies to improve revegetation techniques for interim stabilization control over underground waste sites within the Radiation Area Remedial Action Program. Successful revegetation is an integral aspect of waste isolation strategy. Unfortunately, revegetation can be very difficult to achieve on the Hanford Site due to several factors: low annual precipitation, unpredictable timing of precipitation, low fertility of available soils, and coarse physical texture of soils covering waste sites. The tests in this report were performed during fiscal years 1992 and 1993 and include the use of two soil sealants in combination with bare soil and a soil/compost mixture and a comparison of a wheatgrass mixture and a native seed mixture. Hydroprobe access ports were placed in one-half of the test plots and moisture data was collected. Soil fertility and plant community characteristics were monitored during the two years of the test. During the first year all sites with compost provided additional fertility and retained greater amounts of soil moisture than noncomposted sites. The use of Enduraseal soil fixative provided greater soil moisture than the use of Aerospray-77 soil fixative. During the second year the use of compost and soil fixative's had a lesser effect on soil moisture. During late summer periods all treatments had very similar soil moisture profiles. The use of compost greatly increased vegetative cover and soil fertility in comparison to sites that had no compost added. Testing of the seed mixtures found that Siberian wheatgrass and Sandberg's bluegrass were the most dominant of the seeded species observed. All plots exhibited a dominant plant cover of volunteer cheatgrass. Biomass production was significantly greater on plots with compost than on the noncomposted plots

  14. Influence of Hydraulic Design on Stability and on Pressure Pulsations in Francis Turbines at Overload, Part Load and Deep Part Load based on Numerical Simulations and Experimental Model Test Results

    International Nuclear Information System (INIS)

    Magnoli, M V; Maiwald, M

    2014-01-01

    Francis turbines have been running more and more frequently in part load conditions, in order to satisfy the new market requirements for more dynamic and flexible energy generation, ancillary services and grid regulation. The turbines should be able to be operated for longer durations with flows below the optimum point, going from part load to deep part load and even speed-no-load. These operating conditions are characterised by important unsteady flow phenomena taking place at the draft tube cone and in the runner channels, in the respective cases of part load and deep part load. The current expectations are that new Francis turbines present appropriate hydraulic stability and moderate pressure pulsations at overload, part load, deep part load and speed-no-load with high efficiency levels at normal operating range. This study presents series of investigations performed by Voith Hydro with the objective to improve the hydraulic stability of Francis turbines at overload, part load and deep part load, reduce pressure pulsations and enlarge the know-how about the transient fluid flow through the turbine at these challenging conditions. Model test measurements showed that distinct runner designs were able to influence the pressure pulsation level in the machine. Extensive experimental investigations focused on the runner deflector geometry, on runner features and how they could reduce the pressure oscillation level. The impact of design variants and machine configurations on the vortex rope at the draft tube cone at overload and part load and on the runner channel vortex at deep part load were experimentally observed and evaluated based on the measured pressure pulsation amplitudes. Numerical investigations were employed for improving the understanding of such dynamic fluid flow effects. As example for the design and experimental investigations, model test observations and pressure pulsation curves for Francis machines in mid specific speed range, around n qopt = 50

  15. Core stability: inter- and intraobserver reliability of 6 clinical tests

    NARCIS (Netherlands)

    Weir, Adam; Darby, Jennifer; Inklaar, Han; Koes, Bart; Bakker, Erik; Tol, Johannes L.

    2010-01-01

    Core stability is a complex concept within sports medicine and is thought to play a role in sports injuries. There is a lack of reliable and valid clinical tests for core stability. The inter- and intraobserver reliability of 6 tests commonly used to assess core stability was determined. A video of

  16. FIRST RESULTS FROM OEDOTENSIOMETRIC TESTS

    Directory of Open Access Journals (Sweden)

    Luigi Cavazza

    2008-09-01

    Full Text Available An oedotensiometer was used to examine to examine the behaviour of sieved sample of a swelling soil (a vertisol as well as of the same soils treated with solution of Na+ + Ca2+ to simulate the soil changes from excessive irrigation with brackish water. The oedometer test consisted in an infiltration of water from below through a ceramic porous plate at a feeding pressure of +10 cm water and successive drainage under a depression mostly of -112 cm of water. The rate of water entry as well as the swelling rate of the sample were monitored. Preliminary considerations regards the domains in which the shrinkage curve of a swelling soil is subdivided and make hypothesis on the swelling process expected when the infiltration from below of the sample is applied. The results support the hypothesis that when the water pressure is applied some water enters rather rapidly in the larger structural pores and is followed later by the swelling in the smaller pores, responsible for the basic domain. This first conclusion demonstrates that the assumption of a simultaneous movement of solid and liquid components in the sample, which is the base of most theoretical developments for swelling soils, cannot be accepted for the tested samples. Some cases with water clogging on the sample surface confirm a late final swelling of the soil and permitted to evaluate the hydraulic conductivity of the swollen soil. These manifestations are more evident in sodicated soils. The loading of the sample reduces the swelling of the sample and seems to reduce its permeability. The reduction of the feeding water pressure further reduces the sample swelling. The draining process from saturated soil sample shows that most of the process occurs in the large pores of the structural domain. This gives the possibility to evaluate the water diffusivity coefficient for the structural domain of the sample. In draining the soil with the highest sodication there was a variation of soil volume

  17. New Results of Global Exponential Stabilization for BLDCMs System

    Directory of Open Access Journals (Sweden)

    Fengxia Tian

    2015-01-01

    Full Text Available The global exponential stabilization for brushless direct current motor (BLDCM system is studied. Four linear and simple feedback controllers are proposed to realize the global stabilization of BLDCM with exponential convergence rate; the control law used in each theorem is less conservative and more concise. Finally, an example is given to demonstrate the correctness of the proposed results.

  18. Uncertainty considerations for interferometric stability testing

    NARCIS (Netherlands)

    Ellis, J.D.; Joo, K.N.; Verlaan, A.L.; Spronck, J.W.

    2008-01-01

    Material stability is an important parameter for EUV lithography, space instrumentation, and metrology in general. In both EUV lithography and space, more information is needed about material stability during an atmospheric to vacuum transition. For metrology instruments in general, determining the

  19. Chemical compatibility screening test results

    Energy Technology Data Exchange (ETDEWEB)

    Nigrey, P.J.; Dickens, T.G.

    1997-12-01

    A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) a mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60{degrees}C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m{sup 2} for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals.

  20. Chemical compatibility screening test results

    International Nuclear Information System (INIS)

    Nigrey, P.J.; Dickens, T.G.

    1997-12-01

    A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) a mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60 degrees C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m 2 for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals

  1. Ultrasonic Transducer Irradiation Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Daw, Joshua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Palmer, Joe [Idaho National Lab. (INL), Idaho Falls, ID (United States); Ramuhalli, Pradeep [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Keller, Paul [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Montgomery, Robert [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chien, Hual-Te [Argonne National Lab. (ANL), Argonne, IL (United States); Kohse, Gordon [MIT (Massachusetts Inst. of Technology), Cambridge, MA (United States); Tittmann, Bernhard [Pennsylvania State Univ., University Park, PA (United States); Reinhardt, Brian [Pennsylvania State Univ., University Park, PA (United States); Rempe, Joy [Rempe and Associates, Idaho Falls, ID (United States)

    2015-02-01

    Ultrasonic technologies offer the potential for high-accuracy and -resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other ongoing efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. For this reason, the Pennsylvania State University (PSU) was awarded an ATR NSUF project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2. The goal of this research is to characterize and demonstrate magnetostrictive and piezoelectric transducer operation during irradiation, enabling the development of novel radiation-tolerant ultrasonic sensors for use in Material Testing Reactors (MTRs). As such, this test is an instrumented lead test and real-time transducer performance data is collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. To date, one piezoelectric

  2. Railgun bore material test results

    International Nuclear Information System (INIS)

    Wang, S.Y.; Burton, R.L.; Witherspoon, F.D.; Bloomberg, H.W.; Goldstein, S.A.; Tidman, D.A.; Winsor, N.K.

    1987-01-01

    GT-Devices, Inc. has constructed a material test facility (MTF) to study the fundamental heat transfer problem of both railgun and electrothermal guns, and to test candidate gun materials under real plasma conditions. The MTF electrothermally produces gigawatt-level plasmas with pulse lengths of 10-30 microseconds. Circular bore and non-circular bore test barrels have been successfully operated under a wide range of simulated heating environments for EM launchers. Diagnostics include piezoelectric MHz pressure probes, time-of-flight probes, and current and voltage probes. Ablation measurements are accomplished by weighing and optical inspection, including borescope, optical microscope, and scanning electron microscope (SEM). From these measurements the ablation threshold for both the rail and insulator materials can be determined as a function of plasma heating. The MTF diagnostics are supported by an unsteady 1-D model of MTF which uses the flux-corrected transport (FCT) algorithm to calculate the fluid equations in conservative form. A major advantage of the FCT algorithm is that it can model gas dynamic shock behaviour without the requirement of numerical diffusion. The principle use of the code is to predict the material surface temperature ΔT/α from the unsteady heat transfer q(t)

  3. Irradiation Effects Test Series: Test IE-2. Test results report

    International Nuclear Information System (INIS)

    Allison, C.M.; Croucher, D.W.; Ploger, S.A.; Mehner, A.S.

    1977-08-01

    The report describes the results of a test using four 0.97-m long PWR-type fuel rods with differences in diametral gap and cladding irradiation. The objective of this test was to provide information about the effects of these differences on fuel rod behavior during quasi-equilibrium and film boiling operation. The fuel rods were subjected to a series of preconditioning power cycles of less than 30 kW/m. Rod powers were then increased to 68 kW/m at a coolant mass flux of 4900 kg/s-m 2 . After one hour at 68 kW/m, a power-cooling-mismatch sequence was initiated by a flow reduction at constant power. At a flow of 2550 kg/s-m 2 , the onset of film boiling occurred on one rod, Rod IE-011. An additional flow reduction to 2245 kg/s-m 2 caused the onset of film boiling on the remaining three rods. Data are presented on the behavior of fuel rods during quasiequilibrium and during film boiling operation. The effects of initial gap size, cladding irradiation, rod power cycling, a rapid power increase, and sustained film boiling are discussed. These discussions are based on measured test data, preliminary postirradiation examination results, and comparisons of results with FRAP-T3 computer model calculations

  4. Image Registration for Stability Testing of MEMS

    Science.gov (United States)

    Memarsadeghi, Nargess; LeMoigne, Jacqueline; Blake, Peter N.; Morey, Peter A.; Landsman, Wayne B.; Chambers, Victor J.; Moseley, Samuel H.

    2011-01-01

    Image registration, or alignment of two or more images covering the same scenes or objects, is of great interest in many disciplines such as remote sensing, medical imaging. astronomy, and computer vision. In this paper, we introduce a new application of image registration algorithms. We demonstrate how through a wavelet based image registration algorithm, engineers can evaluate stability of Micro-Electro-Mechanical Systems (MEMS). In particular, we applied image registration algorithms to assess alignment stability of the MicroShutters Subsystem (MSS) of the Near Infrared Spectrograph (NIRSpec) instrument of the James Webb Space Telescope (JWST). This work introduces a new methodology for evaluating stability of MEMS devices to engineers as well as a new application of image registration algorithms to computer scientists.

  5. Partial-array test results in IFSMTF

    International Nuclear Information System (INIS)

    Lue, J.W.; Dresner, L.; Koizumi, K.; Lubell, M.S.; Luton, J.N.; Shen, S.S.; Zahn, G.R.; Zichy, J.A.

    1985-01-01

    Preliminary performance tests of two large superconducting magnets have been carried out in the International Fusion Superconducting Magnet Test Facility (IFSMTF). Each of the Japanese (JA) and General Dynamics/Convair (GD) coils was operated up to its full design current of 10.2 kA with the other serving as an adjacent background coil at 40% of design current. Cryostatic stability was demonstrated for both coils by noting recovery from a full half-turn (5 m) driven normal. A new pick-up coil compensation scheme was successfully used for the quench detection system. Each coil remained superconducting when the other was dumped. Unique instrumentation was used to measure changes in bore dimensions and displacement of the winding from the coil case. Agreement between structural analysis and measurement of bore dimension changes resulting from magnetic loads is good. The Swiss (CH) coil underwent only a cryogenic test. The forced cooling worked well and an inlet temperature of 3.8 K was demonstrated

  6. The validity and reliability of a dynamic neuromuscular stabilization-heel sliding test for core stability.

    Science.gov (United States)

    Cha, Young Joo; Lee, Jae Jin; Kim, Do Hyun; You, Joshua Sung H

    2017-10-23

    Core stabilization plays an important role in the regulation of postural stability. To overcome shortcomings associated with pain and severe core instability during conventional core stabilization tests, we recently developed the dynamic neuromuscular stabilization-based heel sliding (DNS-HS) test. The purpose of this study was to establish the criterion validity and test-retest reliability of the novel DNS-HS test. Twenty young adults with core instability completed both the bilateral straight leg lowering test (BSLLT) and DNS-HS test for the criterion validity study and repeated the DNS-HS test for the test-retest reliability study. Criterion validity was determined by comparing hip joint angle data that were obtained from BSLLT and DNS-HS measures. The test-retest reliability was determined by comparing hip joint angle data. Criterion validity was (ICC2,3) = 0.700 (pTest-retest reliability was (ICC3,3) = 0.953 (pvalidity data demonstrated a good relationship between the gold standard BSLLT and DNS-HS core stability measures. Test-retest reliability data suggests that DNS-HS core stability was a reliable test for core stability. Clinically, the DNS-HS test is useful to objectively quantify core instability and allow early detection and evaluation.

  7. Stability Testing of Beclomethasone Dipropionate Nanoemulsion ...

    African Journals Online (AJOL)

    The nanoemulsions were characterized by droplet size, pH, viscosity, conductivity and refractive index. Stability studies were performed according to International Council on Harmonization (ICH) guidelines over a period of 3 months. Droplet size, pH, viscosity, conductivity and refractive index were determined monthly for 3 ...

  8. ARGO-YBJ: Physics results and detector stabilization

    Energy Technology Data Exchange (ETDEWEB)

    Camarri, P., E-mail: camarri@roma2.infn.it [Università di Roma “Tor Vergata”, Dipartimento di Fisica, Via della Ricerca Scientifica 1, Roma (Italy); INFN, Sezione di Roma Tor Vergata, Via della Ricerca Scientifica 1, Roma (Italy)

    2013-08-01

    The ARGO-YBJ experiment at 4300 m above sea level on the Tibet plateau is a full-coverage array of Resistive Plate Chambers (RPCs) operated in streamer mode, covering a surface of 74×78 m{sup 2} surrounded by a guard ring. It was designed to detect extensive air showers generated by primary cosmic rays in the energy range from a few hundred GeV up to about 1 PeV. It has been running uninterruptedly with its complete layout since October 2007, providing results in γ-ray astrophysics and cosmic-ray physics. Some of the main results obtained by ARGO-YBJ in the study of TeV γ rays from Supernova Remnants and from Active Galactic Nuclei and in the study of the medium-scale cosmic-ray anisotropy will be described. We also discuss the results of a test which proves the feasibility of the control procedure devised to stabilize the response of the detector.

  9. Abnormal Cervical Cancer Screening Test Results

    Science.gov (United States)

    ... lesion? • What are the different types of abnormal Pap test results? • What testing is needed after an abnormal ... that could lead to cancer. Screening includes the Pap test and, for some women, testing for a virus ...

  10. A survey on stability and rigidity results for Lie algebras

    NARCIS (Netherlands)

    Crainic, Marius; Schätz, Florian; Struchiner, Ivan

    2014-01-01

    We give simple and unified proofs of the known stability and rigidity results for Lie algebras, Lie subalgebras and Lie algebra homomorphisms. Moreover, we investigate when a Lie algebra homomorphism is stable under all automorphisms of the codomain (including outer automorphisms).

  11. Consensus stability testing protocols for organic photovoltaic materials and devices

    DEFF Research Database (Denmark)

    Reese, Matthew O.; Gevorgyan, Suren; Jørgensen, Mikkel

    2011-01-01

    Procedures for testing organic solar cell devices and modules with respect to stability and operational lifetime are described. The descriptions represent a consensus of the discussion and conclusions reached during the first 3 years of the international summit on OPV stability (ISOS). The proced...

  12. Test-Retest Stability of Word Retrieval in Aphasic Discourse

    Science.gov (United States)

    Boyle, Mary

    2014-01-01

    Purpose: This study examined the test-retest stability of select word-retrieval measures in the discourses of people with aphasia who completed a 5-stimulus discourse task. Method: Discourse samples across 3 sessions from 12 individuals with aphasia were analyzed for the stability of measures of informativeness, efficiency, main concepts, noun and…

  13. Surface stability test plan for protective barriers

    International Nuclear Information System (INIS)

    Ligotke, M.W.

    1989-01-01

    Natural-material protective barriers for long-term isolation of buried waste have been identified as integral components of a plan to isolate a number of Hanford defense waste sites. Standards currently being developed for internal and external barrier performance will mandate a barrier surface layer that is resistant to the eolian erosion processes of wind erosion (deflation) and windborne particle deposition (formation of sand dunes). Thus, experiments are needed to measure rates of eolian erosion processes impacting those surfaces under different surface and climatological conditions. Data from these studies will provide information for use in the evaluation of selected surface layers as a means of providing stable cover over waste sites throughout the design life span of protective barriers. The multi-year test plan described in this plan is directed at understanding processes of wind erosion and windborne particle deposition, providing measurements of erosion rates for models, and suggesting construction materials and methods for reducing the effect of long-term eolian erosion on the barrier. Specifically, this plan describes possible methods to measure rates of eolian erosion, including field and laboratory procedure. Advantages and disadvantages of laboratory (wind tunnel) tests are discussed, and continued wind tunnel tests are recommended for wind erosion studies. A comparison between field and wind tunnel erosive forces is discussed. Plans for testing surfaces are described. Guidance is also presented for studying the processes controlling sand dune and blowout formation. 24 refs., 7 figs., 3 tabs

  14. Generator Set Environmental and Stability Testing

    Science.gov (United States)

    2015-03-01

    EOT End of Test HFRR High Frequency Reciprocating Rig HRJ-8 Hydro-Renewable Jet Fuel JFTOT Jet Fuel Thermal Oxidation Test kW kilo Watts MEP... Jet -A. The blend was additized with 22.5 ppm DCI-4A and 1 ppm STADIS to bring the blend into conformance with the MIL-DTL-83133G specification. As...Muff psia psia 13.96 1.468 Exh Cyl 3 F 751.9 1.00 Exh Cyl 4 F 763.8 0.97 Power kW 15.6 Exh Manifold F 797.6 0.63 Voltage L1 V 119.2 0.07 After Turbo

  15. Common Diagnostic Test Results Over the Years

    Directory of Open Access Journals (Sweden)

    Aruvee Eve

    2016-12-01

    Full Text Available In this article, common test results over the years 2000 – 2016 are analysed. The test questions for new entrants were based on secondary school mathematics. The students took the test in the first lesson of the higher mathematics course. The test results were analysed by years, by tasks and by specialities, and their differences were found. The test results’ dependence on state-exams score was studied and other types of dependence were looked at.

  16. Testing the stability of travel expenditures in Nigeria

    International Nuclear Information System (INIS)

    Osula, D.O.A.; Adebisi, O.

    2001-01-01

    A report is presented on a study carried out to develop a functional form for travel money expenditure in a Nigerian setting, and test its stability against energy policy change, specifically the fuel price increase of October 1994. The Box-Cox transformation regression approach was adopted in the modelling exercise in order to evolve a data-defined functional form and ensure a more rational basis for the stability test. The results of the modelling exercise show that while statistically significant functional forms were estimated for the 'before' and 'after' fuel price increase periods, the functional forms estimated are not stable across the periods. Thus 'travel budget' is as yet not usable as a term for travel expenditures in Nigeria. The implication of this for travel demand modelling in Nigeria is that, at least till other evidences prove otherwise, there is as yet no basis for using the 'Universal Mechanism of Travel' model developed by Zahavi (The UMOT Project. Report No. DOT-RSPA-DPB-20-79-3; The UMOT Travel Model II Report No. DOT-RSPA-DPB-50-82-11). Of disposable income and total expenditure, the former has proved to be more appropriate for use as 'available money' for the estimation of travel expenditures in Nigeria in the 'before' energy policy change period, while total expenditure proved appropriate in the 'after' period. (author)

  17. Elastic Stability of Concentric Tube Robots: A Stability Measure and Design Test.

    Science.gov (United States)

    Gilbert, Hunter B; Hendrick, Richard J; Webster, Robert J

    2016-02-01

    Concentric tube robots are needle-sized manipulators which have been investigated for use in minimally invasive surgeries. It was noted early in the development of these devices that elastic energy storage can lead to rapid snapping motion for designs with moderate to high tube curvatures. Substantial progress has recently been made in the concentric tube robot community in designing snap-free robots, planning stable paths, and characterizing conditions that result in snapping for specific classes of concentric tube robots. However, a general measure for how stable a given robot configuration is has yet to be proposed. In this paper, we use bifurcation and elastic stability theory to provide such a measure, as well as to produce a test for determining whether a given design is snap-free (i.e. whether snapping can occur anywhere in the unloaded robot's workspace). These results are useful in designing, planning motions for, and controlling concentric tube robots with high curvatures.

  18. Stabilization

    Directory of Open Access Journals (Sweden)

    Muhammad H. Al-Malack

    2016-07-01

    Full Text Available Fuel oil flyash (FFA produced in power and water desalination plants firing crude oils in the Kingdom of Saudi Arabia is being disposed in landfills, which increases the burden on the environment, therefore, FFA utilization must be encouraged. In the current research, the effect of adding FFA on the engineering properties of two indigenous soils, namely sand and marl, was investigated. FFA was added at concentrations of 5%, 10% and 15% to both soils with and without the addition of Portland cement. Mixtures of the stabilized soils were thoroughly evaluated using compaction, California Bearing Ratio (CBR, unconfined compressive strength (USC and durability tests. Results of these tests indicated that stabilized sand mixtures could not attain the ACI strength requirements. However, marl was found to satisfy the ACI strength requirement when only 5% of FFA was added together with 5% of cement. When the FFA was increased to 10% and 15%, the mixture’s strength was found to decrease to values below the ACI requirements. Results of the Toxicity Characteristics Leaching Procedure (TCLP, which was performed on samples that passed the ACI requirements, indicated that FFA must be cautiously used in soil stabilization.

  19. A cohomological stability result for projective schemes over surfaces

    OpenAIRE

    Brodmann, M

    2007-01-01

    Let π : X → X 0 be a projective morphism of schemes such that X 0 is noetherian and essentially of finite type over a field K. Let i ∈ ℕ0, let ℱ be a coherent sheaf of -modules and let ℒ be an ample invertible sheaf over X. We show that the set of associated points of the higher direct image sheaf ultimately becomes constant if n tends to −∞, provided X 0 has dimensione ≦ 2. If , this stability result need not hold any more. To prove this, we show that the set of associated primes of the n-th...

  20. Results of steel containment vessel model test

    International Nuclear Information System (INIS)

    Luk, V.K.; Ludwigsen, J.S.; Hessheimer, M.F.; Komine, Kuniaki; Matsumoto, Tomoyuki; Costello, J.F.

    1998-05-01

    A series of static overpressurization tests of scale models of nuclear containment structures is being conducted by Sandia National Laboratories for the Nuclear Power Engineering Corporation of Japan and the US Nuclear Regulatory Commission. Two tests are being conducted: (1) a test of a model of a steel containment vessel (SCV) and (2) a test of a model of a prestressed concrete containment vessel (PCCV). This paper summarizes the conduct of the high pressure pneumatic test of the SCV model and the results of that test. Results of this test are summarized and are compared with pretest predictions performed by the sponsoring organizations and others who participated in a blind pretest prediction effort. Questions raised by this comparison are identified and plans for posttest analysis are discussed

  1. Test results of HTTR control system

    International Nuclear Information System (INIS)

    Motegi, Toshihiro; Iigaki, Kazuhiko; Saito, Kenji; Sawahata, Hiroaki; Hirato, Yoji; Kondo, Makoto; Shibutani, Hideki; Ogawa, Satoru; Shinozaki, Masayuki; Mizushima, Toshihiko; Kawasaki, Kozo

    2006-06-01

    The plant control performance of the IHX helium flow rate control system, the PPWC helium flow rate control system, the secondary helium flow rate control system, the inlet temperature control system, the reactor power control system and the outlet temperature control system of the HTTR are obtained through function tests and power-up tests. As the test results, the control systems show stable control response under transient condition. Both of inlet temperature control system and reactor power control system shows stable operation from 30% to 100%, respectively. This report describes the outline of control systems and test results. (author)

  2. RESULTS OF INITIAL AMMONIA OXIDATION TESTING

    Energy Technology Data Exchange (ETDEWEB)

    Nash, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Fowley, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-12-30

    This memo presents an experimental survey of aqueous phase chemical processes to remove aqueous ammonia from waste process streams. Ammonia is generated in both the current Hanford waste flowsheet and in future waste processing. Much ammonia will be generated in the Low Activity Waste (LAW) melters.i Testing with simulants in glass melters at Catholic University has demonstrated the significant ammonia production.ii The primary reaction there is the reducing action of sugar on nitrate in the melter cold cap. Ammonia has been found to be a problem in secondary waste stabilization. Ammonia vapors are noxious and destruction of ammonia could reduce hazards to waste treatment process personnel. It is easily evolved especially when ammonia-bearing solutions are adjusted to high pH.

  3. Stability results for convex bodies in geometric tomography

    DEFF Research Database (Denmark)

    Kiderlen, Markus

    2008-01-01

    improve the Holder exponents of known stability results for these transforms.   The key idea for this improvement is to use the fact that support functions of convex bodies are elements of  any spherical Sobolev space of derivative order less than 3/2. As the analytical representation Q(K,.) may......We consider the question in how far a convex body (non-empty compact convex set)  K in n-dimensional space is determined by tomographic measurements (in a broad sense). Usually these measurements are derived from K by geometrical operations like sections, projections and certain averages of those....... We restrict to tomographic measurements F(K,.) that can be written as function on the unit sphere and depend additively on an analytical representation Q(K,.) of K.  The first main result states that F(K,.) is a multiplier-rotation operator of Q(K,.) whenever the tomographic data depends...

  4. SULTAN test facility: Summary of recent results

    International Nuclear Information System (INIS)

    Stepanov, Boris; Bruzzone, Pierluigi; Sedlak, Kamil; Croari, Giancarlo

    2013-01-01

    The test campaigns of the ITER conductors in the SULTAN test facility re-started in December 2011 after three months break. The main focus of the activities is about the qualification tests of the Central Solenoid (CS) conductors, with three different samples for a total six variations of strand suppliers and cable layouts. In 2012, five Toroidal Field (TF) conductor samples have also been tested as part of the supplier and process qualification phase of the European, Korean, Chinese and Russian Federation Agencies. A summary of the test results for all the ITER samples tested in the last period is presented, including an updated statistics of the broad transition, the performance degradation and the impact of layout variations. The role of SULTAN test facility during the ITER construction is reviewed, and the load of work for the next three years is anticipated

  5. Median of patient results as a tool for assessment of analytical stability

    DEFF Research Database (Denmark)

    Jørgensen, Lars Mønster; Hansen, Steen Ingemann; Petersen, Per Hyltoft

    2015-01-01

    BACKGROUND: In spite of the well-established external quality assessment and proficiency testing surveys of analytical quality performance in laboratory medicine, a simple tool to monitor the long-term analytical stability as a supplement to the internal control procedures is often needed. METHOD......: Patient data from daily internal control schemes was used for monthly appraisal of the analytical stability. This was accomplished by using the monthly medians of patient results to disclose deviations from analytical stability, and by comparing divergences with the quality specifications for allowable...... control procedures are the most reliable sources of material as they represent the genuine substance of the measurements and therefore circumvent the problems associated with non-commutable materials in external assessment. CONCLUSION: Patient medians in the monthly monitoring of analytical stability...

  6. Reliability test results of LGE pulse tube cryocooler

    Science.gov (United States)

    Kim, S.-Y.; Chung, W.-S.; Park, J.-J.; Hwang, D.-K.; Lee, H.-K.

    2002-05-01

    A low-cost and highly reliable cryocooler is strongly required for several applications. In this circumstance, LG Electronics has developed a 5 W at 65 K pulse tube cryocooler with high potential for low-cost manufacturing based on linear motor and compressor technology. Recently dozens of coolers have been fabricated and tested for the verification of performance stability with ambient temperature variation. From tests at high ambient temperature like 60°C, an average performance degradation of 45% is found and good performance stability of coolers is shown. Continuous operation at 40°C is ongoing for the verification of their reliability. To date no failure has been found. This paper discusses the test process, results and MTBF calculation.

  7. Comparing Motor Control Exercise and General Exercise on Lumbo-Pelvic Stability of Chronic Nonspecific Low Back Pain Sufferers Using Endurance Stability Tests

    Directory of Open Access Journals (Sweden)

    Mohammad Bagher Shamsi

    2018-01-01

    Conclusion Though it is claimed that MCE increases spinal stability, the lack of significant difference in the results of variables between the two groups may be due to our MCE not being specific for increasing spinal stability or equal effects of both interventions on increasing spinal stability and no preference of MCE. It may also be due to poor sensitivity of our outcome measures in detecting changes in spinal stability, especially with respect to the sample size. Based on these results, it could be concluded that MCE is not more effective than GE in improving endurance core stability tests and reducing disability and pain in chronic non-specific LBP patients.

  8. NEXT Single String Integration Test Results

    Science.gov (United States)

    Soulas, George C.; Patterson, Michael J.; Pinero, Luis; Herman, Daniel A.; Snyder, Steven John

    2010-01-01

    As a critical part of NASA's Evolutionary Xenon Thruster (NEXT) test validation process, a single string integration test was performed on the NEXT ion propulsion system. The objectives of this test were to verify that an integrated system of major NEXT ion propulsion system elements meets project requirements, to demonstrate that the integrated system is functional across the entire power processor and xenon propellant management system input ranges, and to demonstrate to potential users that the NEXT propulsion system is ready for transition to flight. Propulsion system elements included in this system integration test were an engineering model ion thruster, an engineering model propellant management system, an engineering model power processor unit, and a digital control interface unit simulator that acted as a test console. Project requirements that were verified during this system integration test included individual element requirements ; integrated system requirements, and fault handling. This paper will present the results of these tests, which include: integrated ion propulsion system demonstrations of performance, functionality and fault handling; a thruster re-performance acceptance test to establish baseline performance: a risk-reduction PMS-thruster integration test: and propellant management system calibration checks.

  9. A stability result for the magnetic shaping problem

    Science.gov (United States)

    Descloux, Jean

    1994-07-01

    We consider the bidimensional magnetic shaping problem without surface tension and study its stability when the boundary Γ of the domain has cusp points. We show in particular that one has stability when the curvature of the smooth parts of Γ is negative.

  10. Investigation of Indoor Stability Testing of Polymer Solar Cell

    Directory of Open Access Journals (Sweden)

    Pelin Kavak

    2016-01-01

    Full Text Available We have fabricated organic solar cell of a new low bandgap polymer poly[4,4-bis(2-ethylhexyl-4H-cyclopenta[2,1-b:3,4-b′]dithiophene-2,6-diyl-alt-4,7-bis(2-thienyl-2,1,3-benzothiadiazole-5′,5′′-diyl] (PCPDTTBTT. We have investigated for the first time the stability tests, ISOS-L-1 and ISOS-D-3, of PCPDTTBTT solar cells. Thermal annealing of PCPDTTBTT solar cells at 80°C brought about an improvement of photocurrent generation, stability, and efficiency of the solar cells. T80 value of PCPDTTBTT solar cell is about 150 hours which is close to P3HT (235 h. PCPDTTBTT is very promising polymer for both polymer solar cell efficiency and stability.

  11. Initial Burn Pan (JMTF) Testing Results

    Science.gov (United States)

    2016-03-01

    Accession Number 3. Recipient’s Catalog No. 4. Title and Subtitle Initial Burn Pan (JMTF) Testing Results 5. Report Date March 2016 6...trough is filled with water to provide cooling of the fire pan walls. Figure 4 shows the interior of the refurbished burn pan. There are a number of...first test (static burn of 378 liters (100 gallons) of diesel), was used to calculate the fuel regression based on the fuel depth prior to the fire and

  12. Acknowledging the results of blood tests

    DEFF Research Database (Denmark)

    Torkilsheyggi, Arnvør Martinsdottir á; Hertzum, Morten

    At the studied hospital, physicians from the Medical and Surgical Departments work some of their shifts in the Emergency Department (ED). Though icons showing the blood-test process were introduced on electronic whiteboards in the ED, these icons did not lead to increased attention to test...... acknowledgement. Rather, the physicians, trans-ferred work practices from their own departments, which did not have electronic white-boards, to the ED. This finding suggests a challenge to the cross-disciplinary work and norms for how to follow up on blood-test results in the ED....

  13. Acid Pit Stabilization Project (Volume 1 - Cold Testing) and (Volume 2 - Hot Testing)

    Energy Technology Data Exchange (ETDEWEB)

    G. G. Loomis (INEEL); A. P. Zdinak (MSE); M. A. Ewanic (MSE); J. J. Jessmore (INEEL)

    1998-01-01

    During the summer and fall of Fiscal Year 1997, a Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Treatability Study was performed at the Idaho National Engineering and Environmental Laboratory. The study involved subsurface stabilization of a mixed waste contaminated soil site called the Acid Pit. This study represents the culmination of a successful technology development effort that spanned Fiscal Years 1994-1996. Research and development of the in situ grout stabilization technique was conducted. Hardware and implementation techniques are currently documented in a patent pending with the United States Patent and Trademark Office. The stabilization technique involved using jet grouting of an innovative grouting material to form a monolith out of the contamination zone. The monolith simultaneously provides a barrier to further contaminant migration and closes voids in the soil structure against further subsidence. This is accomplished by chemical incorporation of contaminants into less soluble species and achieving a general reduction in hydraulic conductivity within the monolith. The grout used for this study was TECT-HG, a relatively dense iron oxide-based cementitious grout. The treatability study involved cold testing followed by in situ stabilization of the Acid Pit. Volume 1 of this report discusses cold testing, performed as part of a ''Management Readiness Assessment'' in preparation for going hot. Volume 2 discusses the results of the hot Acid Pit Stabilization phase of this project. Drilling equipment was specifically rigged to reduce the spread of contamination, and all grouting was performed under a concrete block containing void space to absorb any grout returns. Data evaluation included examination of implementability of the grouting process and an evaluation of the contaminant spread during grouting. Following curing of the stabilized pit, cores were obtained and evaluated for toxicity

  14. Results of interlaboratory tests regarding TXRF

    International Nuclear Information System (INIS)

    Klockenkaemper, R.; Bohlen, A. von

    2000-01-01

    Interlaboratory or intercomparison tests can be performed for proficiency testing of individual laboratories, for the certification of a special sample material and for the validation of a certain method. We participated in two interlaboratory tests in order to validate total reflection x-ray fluorescence analysis (TXRF). We used our results to evaluate TXRF and to compare it with other competing methods, particularly with respect of precision and accuracy. The first interlaboratory test was organized by IAEA (International Atomic Energy Agency, Vienna, Austria). As a candidate for reference material, a lichen (IAEA-336 Lichen) was distributed among 27 participants. In our laboratory, the powdered biogenic material was digested with nitric acid under high pressure and analyzed by TXRF. - The second interlaboratory test was organized by IRMM (Institute for Reference Materials and Measurements, Geel, Belgium). As a certified test sample with undisclosed values, a sediment (IMEP-14) was delivered to 220 laboratories. We digested the geogenic material again by nitric acid and additionally by hydrofluoric acid and analyzed it by TXRF. - In both test samples, six or eight different trace elements, respectively, were determined by TXRF with a content between 2 and 2000 mg/kg. Calibration was carried out by internal standardization. For that purpose, Ga or Se, respectively, was added as standard element. The measurement uncertainty of TXRF was estimated by the method of error propagation. In our paper we will report on the results of the two interlaboratory tests. It will be shown that TXRF is highly reliable for a correct determination of trace elements in biogenic and geogenic samples. It is competitive with the established methods of trace analyses which were involved in these tests and it is even superior to them in certain aspects. (author)

  15. BPX insulation irradiation program test results

    International Nuclear Information System (INIS)

    McManamy, T.J.; Kanemoto, G.; Snook, P.G.

    1991-01-01

    The toroidal field coil insulation for the Burning Plasma Experiment (BPX) is expected to receive a radiation dose of nearly 10 10 rad and to withstand significant mechanical stresses. An irradiation test program was performed at the Idaho National Engineering Laboratory (INEL) using the Advanced Technology Reactor (ATR) for irradiations to doses on the order of 3 x 10 10 rad. The flexure and shear strength with compression of commercially procured sheet material were reported earlier. A second series of tests has been performed to slightly higher dose levels with vacuum impregnated materials, glass strand material, and Spaulrad-S sheet samples. Vacuum impregnation with a Shell 9405 resin and 9470 hardener was used to produce bonded copper squares and flexure samples of both pure resin and resin with S-glass. A new test fixture was developed to test the bonded samples in shear without applied compression. The Spaulrad-S flexure samples demonstrated a loss of strength with irradiation, similar to previous results. The pure resin lost nearly all flexibility, while the S-glass-reinforced samples retained between 30% and 40% of the initial flexure strength. The S-glass strands showed a 30% loss of strength at the higher dose level when tested in tension. The bonded copper squares had a low room-temperature shear strength of approximately 17 MPa before irradiation, which was unchanged in the irradiated samples. Shear testing of unirradiated bonded copper squares with ten different types of surface treatment revealed that the low shear strength resulted from the polyurethane primer used. In the later series of test, the epoxy-based primers and DZ-80 from Ciba-Geigy did much better, with shear strengths on the order of 40 MPa. These samples also demonstrated a resistance to cryogenic shock. One irradiated bonded sample was tested up 10 210 MPa in compression, the limit of the test fixture, without failure

  16. Test Results of PBMR Fuel Spheres

    International Nuclear Information System (INIS)

    Koshcheev, Konstantin; Diakov, Alexander; Beltyukov, Igor; Barybin, Andrey; Chernetsov, Mikhail

    2014-01-01

    Results of pre-irradiation testing of fuel spheres (FS) and coated particles (CP) manufactured by PBMR SOC (Republic of South Africa) are described. The stable high quality level of major characteristics (dimensions, CP coating structure, uranium-235 contamination of the FS matrix graphite and the outer PyC layer of the CP coating) are shown. Results of a methodical irradiation test of two FS in helium and neon medium at temperatures of 800 to 1300 °C with simultaneous determination of release-to-birth ratios for major gaseous fission products (GFP) are described. (author)

  17. Electromagnetic results of the Japanese LCT coil's domestic test

    International Nuclear Information System (INIS)

    Nishi, Masataka; Okuno, Kiyoshi; Takahashi, Yoshikazu; Tsuji, Hiroshi; Ando, Toshinari; Shimamoto, Susumu

    1984-01-01

    The domestic test of the Japanese LCT coil was carried out in 1982. During this test, the coil was charged up to the single coil's 100% state (10.22kA, 6.4T, 106MJ) four times and experienced no quenche. at the 100% charging state, coil stability was tested by using heaters installed in the conductor. A half turn length normal zone (about 5 m) generated by heaters was spontenously disappeared in 2 second. This normalized zone included the highest magnetic field position. The transport current which gives the stable limit is extraporated to be about 12.5kA at 8T by this test result. The dump test was carried out also from the 100% charging state. At that time, about 90% of the coil's stored energy was extracted by the dump resistor and the coil was not damaged. (author)

  18. Cone Penetrometer N Factor Determination Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Follett, Jordan R.

    2014-03-05

    This document contains the results of testing activities to determine the empirical 'N Factor' for the cone penetrometer in kaolin clay simulant. The N Factor is used to releate resistance measurements taken with the cone penetrometer to shear strength.

  19. Further Results on Finite-Time Partial Stability and Stabilization. Applications to Nonlinear Control Systems

    International Nuclear Information System (INIS)

    Jammazi, Chaker

    2009-01-01

    The paper gives Lyapunov type sufficient conditions for partial finite-time and asymptotic stability in which some state variables converge to zero while the rest converge to constant values that possibly depend on the initial conditions. The paper then presents partially asymptotically stabilizing controllers for many nonlinear control systems for which continuous asymptotically stabilizing (in the usual sense) controllers are known not to exist.

  20. Influence of Age on Patch Tests Results

    Directory of Open Access Journals (Sweden)

    Aouatef Mahfoudh

    2017-03-01

    Full Text Available Objective: To assess the influence of age on the patch-test results and to compare the profiles of skin sensitizers according to the age groups. Methods: It is an 8-year retrospective study involving entire medical records of the patients with allergic contact dermatitis at the Unity of Dermatology and Allergology in the Department of Occupational Medicine, University Hospital of Sousse in Tunisia. Study population was divided into two age groups (group 1: patients 40 years. The statistical significance level was taken as p<0.05. Results: Among the patients, 586 have had at least one positive reaction to the patch-test. Older individuals were 1.1 times more likely to have at least one positive reaction to the patch-test than younger ones. The most common allergens in both groups are potassium dichromate (34.2% vs. 38%, thiuram mix (6% vs. 11%, cobalt chloride (27% vs. 28.8%, balsam of Peru (6% vs. 11.3% and nickel sulphate (41% vs. 27.3%. A significant variation was noted for potassium dichromate in terms of intensity of skin reaction (p=0.00. Conclusion: More research is needed to elucidate the physiologic mechanisms of age on the patch-test results and to adapt the European Standard Battery to each age group in term of allergen type and their appropriate concentration.

  1. Demonstration Results on the Effects of Mercury Speciation on the Stabilization of Wastes

    International Nuclear Information System (INIS)

    Conley, T.B.; Hulet, G.A.; Morris, M.I.; Osborne-Lee, I.W.

    1999-01-01

    Mercury-contaminated wastes are currently being stored at approximately 19 Department of Energy sites, the volume of which is estimated to be about 16m(sup)3. These wastes exist in various forms including soil, sludges, and debris, which present a particular challenge regarding possible mercury stabilization methods. This reports provides the test results of three vendors, Allied Technology Group, IT Corporation, and Nuclear Fuel Services, Inc., that demonstrate the effects of mercury speciation on the stabilization of the mercury wastes. Mercury present in concentrations that exceed 260 parts per million must be removed by extraction methods and requires stabilization to ensure that the final wasteforms leach less than 0.2mg/L of mercury by the Toxicity Characteristic Leaching Procedure or 0.025 mg/L using the Universal Treatment Standard

  2. Field Cone Penetration Tests with Various Penetration Rates - Test Results

    DEFF Research Database (Denmark)

    Poulsen, Rikke; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    was encountered at approximately 0.2-0.6 m below the ground level. The soil stratigraphy of the test site was before test start identified by geotechnical borings results. The geotechnical borings indicated that the site contains of sandy silt with clay stripes from approx. 4.0 to 10 m. In the top the silty soil...... is very sandy with few clay stripes, and gradually the clay stripes increases wherefore the soil from approx. 10 m contains of clay with sandy silt stripes. Large soil sample was also collected from the test site in order to determine basic soil properties in the laboratory.......The test site is located at Nordre Ringgade near the town called Dronninglund in the northern Jutland in Denmark. The site area is relatively flat, and was chosen because it has a size of approximately 3 ha and contains a relatively thick deposit of silty soils. Furthermore the groundwater...

  3. CLSM bleed water reduction test results

    International Nuclear Information System (INIS)

    Langton, C.A.; Rajendran, N.

    1997-01-01

    Previous testing by BSRI/SRTC/Raytheon indicated that the CLSM specified for the Tank 20 closure generates about 6 gallons (23 liters) of bleed water per cubic yard of material (0.76 m3).1 This amount to about 10 percent of the total mixing water. HLWE requested that the CLSM mix be optimized to reduce bleed water while maintaining flow. Elimination of bleed water from the CLSM mix specified for High-Level Waste Tank Closure will result in waste minimization, time savings and cost savings. Over thirty mixes were formulated and evaluated at the on-site Raytheon Test Laboratory. Improved low bleed water CLSM mixes were identified. Results are documented in this report

  4. SCD1 thermal design and test result analysis

    Science.gov (United States)

    Cardoso, Humberto Pontes; Muraoka, Issamu; Mantelli, Marcia Barbosa Henriques; Leite, Rosangela M. G.

    1990-01-01

    The SCD 01 (Satelite de Coleta de Dados 01) is a spin stabilized low Earth orbit satellite dedicated to the collection and distribution of environmental data. It was completely developed at the Brazilian Institute for Space Research (INPE) and is scheduled to be launched in 1992. The SCD 01 passive thermal control design configuration is presented and the thermal analysis results are compared with the temperatures obtained from a Thermal Balance Test. The correlation between the analytical and experimental results is considered very good. Numerical flight simulations show that the thermal control design can keep all the subsystem temperatures within their specified temperature range.

  5. Preliminary results of dancing exercise on postural stability in adolescent females.

    Science.gov (United States)

    Cheng, Hsu-Sheng; Law, Cheung-Lun; Pan, Hui-Fang; Hsiao, Yueh-Ping; Hu, Jeng-Ho; Chuang, Fu-Kai; Huang, Mao-Hsiung

    2011-12-01

    Twenty-six female student dancers of Chung-hua school of Art (mean age 17.5 ± 0.5 years) and twenty-five healthy active female collegiate students (mean age 18.1 ± 1.0 years) participated in this study to investigate the effects of dancing exercise on postural stability of adolescent female through a comparison study of two cohorts. The groups were matched in height and weight. Participants were excluded for left-side dominance, sustained lower extremity injury, any known vestibular system dysfunction, uncorrected visual problems, and other neurological conditions. Static and dynamic standing balances were measured by means of Biodex Stability System in six conditions include bilateral, dominant, and nondominant single leg stances with eye-open and eye-closed conditions. To investigate the difference between static and dynamic stabilities, two protocols were performed: the first protocol consisted of four positions including static position, Level 8, Level 4, and Level 1, respectively. They were instructed to maintain a level platform as stably as possible for a period of 30 seconds for each test and given a 30-second rest between tests. The second protocol was descending stability level that was gradually changed from Level 12 to Level 1 for 60 seconds. Balance indices included overall stability index, anterior-posterior stability index (APSI), and medial-lateral stability index. The results of first protocol showed that there were significant differences in overall stability index score between study and control groups at Level 8 with dominant single leg standing in the eye-open condition and the APSI score at Level 8 and at Level 4 with dominant single-leg standing in the eye-closed condition. There was no significant difference in the second protocol. The possible explanation is loss of familiarization adaptation because of level change consequently in both the groups, not step-by-step as in the first protocol study. Furthermore, a positive correlation was

  6. Thermal Stability Results of a Fischer-Tropsch Fuel With Various Blends of Aromatic Solution

    Science.gov (United States)

    Lindsey, Jennifer; Klettlinger, Suder

    2013-01-01

    Fischer-Tropsch (F-T) jet fuel composition differs from petroleum-based, conventional commercial jet fuel because of differences in feedstock and production methodology. F-T fuel typically has a lower aromatic and sulfur content and consists primarily of iso and normal paraffins. The ASTM D3241 specification for Jet Fuel Thermal Oxidation Test (JFTOT) break point testing method was used to test the breakpoint of a baseline commercial grade F-T jet fuel, and various blends of this F-T fuel with an aromatic solution. The goal of this research is to determine the effect of aromatic content on the thermal stability of F-T fuel. The testing completed in this report was supported by the NASA Fundamental Aeronautics Subsonic Fixed Wing Project. Two different aromatic content fuels from Rentech, as well as these fuels with added aromatic blend were analyzed for thermal stability using the JFTOT method. Preliminary results indicate a reduction in thermal stability occurs upon increasing the aromatic content to 10% by adding an aromatic blend to the neat fuel. These results do not specify a failure based on pressure drop, but only on tube color. It is unclear whether tube color correlates to more deposition on the tube surface or not. Further research is necessary in order to determine if these failures are true failures based on tube color. Research using ellipsometry to determine tube deposit thickness rather than color will be continued in follow-up of this study.

  7. Comparing core stability and traditional trunk exercise on chronic low back pain patients using three functional lumbopelvic stability tests.

    Science.gov (United States)

    Shamsi, Mohammad Bagher; Sarrafzadeh, Javad; Jamshidi, Aliashraf

    2015-02-01

    It is a matter of controversy whether core stability exercise is preferred to other types of exercise for chronic low back pain. Lumbopelvic stability is an important element in low back pain. No study was found using lumbopelvic stability tests in comparing core stability and other exercises. The single leg squat, dip test, and runner pose test appear to be suitable as tests for lumbopelvic stability. The aim of this study was to compare "core stability" and "traditional trunk exercise" using these tests and also the Oswestry disability questionnaire and pain intensity. Twenty-nine non-specific chronic low back pain subjects were alternately allocated in one of the two exercise groups. For both groups, a 16-sessions exercise program was provided. Before and after training: (1) video was recorded while subjects performed the tests; (2) Oswestry disability questionnaire was completed; and (3) pain intensity was measured by visual analogue scale. The test videos were scored by three physiotherapists. Statistical analysis revealed a significant improvement in stability test scores (p = 0.020 and p = 0.041) and reduction in disability (p stability or equal effectiveness of TTE and CSE on improving LPS. The non-significant differences may also be attributable to the lack of sensitivity of our tests to assess stability change in two groups after training given the relatively small sample size.

  8. Asymptotic stability results for retarded differential systems | Igobi ...

    African Journals Online (AJOL)

    ... matrices are used in formulating a Lyapunov functional. The introduction of convex set segment of a symmetric matrix is explored to establish boundedness of the first derivative of the formulated functional. The integral-differential equation is utilized in computing the maximum delay interval for the system to attain stability.

  9. Test Results From a High Power Linear Alternator Test Rig

    Science.gov (United States)

    Birchenough, Arthur G.; Hervol, David S.; Gardner, Brent G.

    2010-01-01

    Stirling cycle power conversion is an enabling technology that provides high thermodynamic efficiency but also presents unique challenges with regard to electrical power generation, management, and distribution. The High Power Linear Alternator Test Rig (HPLATR) located at the NASA Glenn Research Center (GRC) in Cleveland, Ohio is a demonstration test bed that simulates electrical power generation from a Stirling engine driven alternator. It implements the high power electronics necessary to provide a well regulated DC user load bus. These power electronics use a novel design solution that includes active rectification and power factor control, active ripple suppression, along with a unique building block approach that permits the use of high voltage or high current alternator designs. This report describes the HPLATR, the test program, and the operational results.

  10. Synthesis of low cycle fatigue test results

    International Nuclear Information System (INIS)

    Andrews, R.M.

    1990-01-01

    Axial strain controlled cycle fatigue tests were carried out on type 316 stainless steel parent metal, vacuum and non-vacuum electron beams welds, submerged arc welds and gas shielded metal arc welds. Testing covered total strains in the range 0.6% to 2%, and was at room temperature and 550 0 C. Parent metal and the electron beam welds showed rapid cyclic hardening, while arc welds showed little hardening. The weld metal cyclic stress-strain response was above that obtained for the parent metal, although below data obtained by other workers for similar parent materials. Weld metal endurances were above the ASME N47 continuous cycling design line at both temperatures, and comparable with parent metal data. However, the weld metal data approached the design line at low strain ranges (around 0.5%). Endurances were predicted from crack growth rates estimated from striation spacings, giving acceptable results except for the gas shielded metal arc weldments. (author)

  11. Stability Analysis Of Earth Dam Slopes Subjected To Earthquake Using ERT Results Interpretation

    Directory of Open Access Journals (Sweden)

    Eko Andi Suryo

    2018-01-01

    Full Text Available Earth Dam stability can be affected significantly by the existence of excessive leakage. This is due to decreasing of shear strength of the dam material and additional overturning moment. In such scenario, the non-destructive soil investigation method is needed to analyze the stability of earth dam in current condition. This paper examines the use of Electrical Resistivity Tomography (ERT to investigate soil layers and to measure parameters of soil shear strength indirectly. First survey was carried out at dam crest and downstream using Wenner Configuration along profile lines at electrode spacing of 5 m. There were 5 profile lines of 180m long each and 10m distance of spacing. Furthermore, two profiles lines at weak cross-section based on its resistivity soil values were undertaken. Laboratory tests were conducted to determine relationship between resistivity value, moisture content, cohesion and angle of friction for each type of dam materials. From the ERT results and lab testing, a model dam can be obtained using current material parameters to perform stability analysis of dam subjected to earthquake. The lowest FOS was found at the upstream side about 1.15 and at the downstream side about 1.14 after applying seismic load of 100 years return period. Keywords: Stability Analysis, ERT,resistivity, leakage, dam

  12. Arc melter demonstration baseline test results

    Energy Technology Data Exchange (ETDEWEB)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; Oden, L.L.; O`Connor, W.K.; Turner, P.C.

    1994-07-01

    This report describes the test results and evaluation for the Phase 1 (baseline) arc melter vitrification test series conducted for the Buried Waste Integrated Demonstration program (BWID). Phase 1 tests were conducted on surrogate mixtures of as-incinerated wastes and soil. Some buried wastes, soils, and stored wastes at the INEL and other DOE sites, are contaminated with transuranic (TRU) radionuclides and hazardous organics and metals. The high temperature environment in an electric arc furnace may be used to process these wastes to produce materials suitable for final disposal. An electric arc furnace system can treat heterogeneous wastes and contaminated soils by (a) dissolving and retaining TRU elements and selected toxic metals as oxides in the slag phase, (b) destroying organic materials by dissociation, pyrolyzation, and combustion, and (c) capturing separated volatilized metals in the offgas system for further treatment. Structural metals in the waste may be melted and tapped separately for recycle or disposal, or these metals may be oxidized and dissolved into the slag. The molten slag, after cooling, will provide a glass/ceramic final waste form that is homogeneous, highly nonleachable, and extremely durable. These features make this waste form suitable for immobilization of TRU radionuclides and toxic metals for geologic timeframes. Further, the volume of contaminated wastes and soils will be substantially reduced in the process.

  13. Stability results for a soil model with singular hysteretic hydrology

    Czech Academy of Sciences Publication Activity Database

    Krejčí, Pavel; O'Kane, J.P.; Pokrovskii, A.; Rachinskii, D.

    2011-01-01

    Roč. 268, č. 1 (2011), 012016 ISSN 1742-6588. [5th International workshop on multi-rate processes and hysteresis. Pecs, 31.05.2010-03.06.2010] R&D Projects: GA ČR GAP201/10/2315 Institutional research plan: CEZ:AV0Z10190503 Keywords : hysteresis * evolution equation * stability Subject RIV: BA - General Mathematics http://iopscience.iop.org/1742-6596/268/1/012016

  14. Standard Test Method for Dimensional Stability of Sandwich Core Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the sandwich core dimensional stability in the two plan dimensions. 1.2 The values stated in SI units are to be regarded as the standard. The inch-pound units given may be approximate. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. Slope stability and bearing capacity of landfills and simple on-site test methods.

    Science.gov (United States)

    Yamawaki, Atsushi; Doi, Yoichi; Omine, Kiyoshi

    2017-07-01

    This study discusses strength characteristics (slope stability, bearing capacity, etc.) of waste landfills through on-site tests that were carried out at 29 locations in 19 sites in Japan and three other countries, and proposes simple methods to test and assess the mechanical strength of landfills on site. Also, the possibility of using a landfill site was investigated by a full-scale eccentric loading test. As a result of this, landfills containing more than about 10 cm long plastics or other fibrous materials were found to be resilient and hard to yield. An on-site full scale test proved that no differential settlement occurs. The repose angle test proposed as a simple on-site test method has been confirmed to be a good indicator for slope stability assessment. The repose angle test suggested that landfills which have high, near-saturation water content have considerably poorer slope stability. The results of our repose angle test and the impact acceleration test were related to the internal friction angle and the cohesion, respectively. In addition to this, it was found that the air pore volume ratio measured by an on-site air pore volume ratio test is likely to be related to various strength parameters.

  16. Aerodynamic and Acoustic Flight Test Results and Results for the Stratospheric Observatory for Infrared Astronomy

    Science.gov (United States)

    Cumming, Stephen B.; Smith, Mark S.; Cliatt, Larry J.; Frederick, Michael A.

    2014-01-01

    As part of the Stratospheric Observatory for Infrared Astronomy program, a 747SP airplane was modified to carry a 2.5-m telescope in the aft section of the fuselage. The resulting airborne observatory allows for observations above 99 percent of the water vapor in the atmosphere. The open cavity created by the modifications had the potential to significantly affect the airplane in the areas of aerodynamics and acoustics. Several series of flight tests were conducted to clear the operating envelope of the airplane for astronomical observations, planned to be performed between the altitudes of 35,000 ft and 45,000 ft. The flight tests were successfully completed. Cavity acoustics were below design limits, and the overall acoustic characteristics of the cavity were better than expected. The modification did have some effects on the stability and control of the airplane, but these effects were not significant. Airplane air data systems were not affected by the modifications. This paper describes the methods used to examine the aerodynamics and acoustic data from the flight tests and provides a discussion of the flight-test results in the areas of cavity acoustics, stability and control, and air data.

  17. Operational stability prediction in milling based on impact tests

    Science.gov (United States)

    Kiss, Adam K.; Hajdu, David; Bachrathy, Daniel; Stepan, Gabor

    2018-03-01

    Chatter detection is usually based on the analysis of measured signals captured during cutting processes. These techniques, however, often give ambiguous results close to the stability boundaries, which is a major limitation in industrial applications. In this paper, an experimental chatter detection method is proposed based on the system's response for perturbations during the machining process, and no system parameter identification is required. The proposed method identifies the dominant characteristic multiplier of the periodic dynamical system that models the milling process. The variation of the modulus of the largest characteristic multiplier can also be monitored, the stability boundary can precisely be extrapolated, while the manufacturing parameters are still kept in the chatter-free region. The method is derived in details, and also verified experimentally in laboratory environment.

  18. Boeing's High Voltage Solar Tile Test Results

    Science.gov (United States)

    Reed, Brian J.; Harden, David E.; Ferguson, Dale C.; Snyder, David B.

    2002-01-01

    Real concerns of spacecraft charging and experience with solar array augmented electrostatic discharge arcs on spacecraft have minimized the use of high voltages on large solar arrays despite numerous vehicle system mass and efficiency advantages. Boeing's solar tile (patent pending) allows high voltage to be generated at the array without the mass and efficiency losses of electronic conversion. Direct drive electric propulsion and higher power payloads (lower spacecraft weight) will benefit from this design. As future power demand grows, spacecraft designers must use higher voltage to minimize transmission loss and power cable mass for very large area arrays. This paper will describe the design and discuss the successful test of Boeing's 500-Volt Solar Tile in NASA Glenn's Tenney chamber in the Space Plasma Interaction Facility. The work was sponsored by NASA's Space Solar Power Exploratory Research and Technology (SERT) Program and will result in updated high voltage solar array design guidelines being published.

  19. Mechanical Stability Study for Integrable Optics Test Accelerator at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    McGee, Mike [Fermilab; Andrews, Richard [Fermilab; Carlson, Kermit [Fermilab; Leibfritz, Jerry [Fermilab; Nobrega, Lucy [Fermilab; Valishev, Alexander [Fermilab

    2016-07-01

    The Integrable Optics Test Accelerator (IOTA) is proposed for operation at Fermilab. The goal of IOTA is to create practical nonlinear accelerator focusing systems with a large frequency spread and stable particle motion. The IOTA is a 40 m circumference, 150 MeV (e-), 2.5 MeV (p⁺) diagnostic test ring. A heavy low frequency steel floor girder is proposed as the primary tier for IOTA device component support. Two design lengths; (8) 4 m and (2) 2.8 m long girders with identical cross section completely encompass the ring. This study focuses on the 4 m length girder and the development of a working prototype. Hydrostatic Level Sensor (HLS), temperature, metrology and fast motion measurements characterize the anticipated mechanical stability of the IOTA ring.

  20. DC-10 composite vertical stabilizer ground test program

    Science.gov (United States)

    Palmer, J. M., Jr.; Stephens, C. O.; Sutton, J. O.

    1983-01-01

    A review of the structural configuration and ground test program is presented. Particular emphasis is placed on the testing of a full-scale stub box test subcomponent and full span ground test unit. The stub box subcomponent was tested in an environmental chamber under ambient, cold/wet, and hot/wet conditions. The test program included design limit static loads, fatigue spectrum loading to approximately two service lifetimes (with and without damage), design limit damage tolerance tests, and a final residual strength test to a structural failure. The first full-scale ground test unit was tested under ambient conditions. The test unit was to have undergone static, fatigue, and damage tolerance tests but a premature structural failure occurred at design limit load during the third limit load test. A failure theory was developed which explains the similarity in types of failure and the large load discrepancy at failure between the two test articles. The theory attributes both failures to high stress concentrations at the edge of the lower rear spar access opening. A second full-scale ground test unit has been modified to incorporate the various changes resulting from the premature failure. The article has been assembled and is active in the test program.

  1. Experimental Testing for Stability Analysis of Distributed Energy Resources Components with Storage Devices and Loads

    DEFF Research Database (Denmark)

    Mihet-Popa, Lucian; Groza, Voicu; Isleifsson, Fridrik Rafn

    2012-01-01

    Experimental Testing for Stability Analysis of Distributed Energy Resources Components with Storage Devices and Loads......Experimental Testing for Stability Analysis of Distributed Energy Resources Components with Storage Devices and Loads...

  2. Full length prototype SSC dipole test results

    International Nuclear Information System (INIS)

    Strait, J.; Brown, B.C.; Carson, J.

    1987-01-01

    Results are presented from tests of the first full length prototype SSC dipole magnet. The cryogenic behavior of the magnet during a slow cooldown to 4.5K and a slow warmup to room temperature has been measured. Magnetic field quality was measured at currents up to 2000 A. Averaged over the body field all harmonics with the exception of b 2 and b 8 are at or within the tolerances specified by the SSC Central Design Group. (The values of b 2 and b 8 result from known design and construction defects which will be be corrected in later magnets.) Using an NMR probe the average body field strength is measured to be 10.283 G/A with point to point variations on the order of one part in 1000. Data are presented on quench behavior of the magnet up to 3500 A (approximately 55% of full field) including longitudinal and transverse velocities for the first 250 msec of the quench

  3. Evaluation of seismic testing for quality assurance of lime-stabilized soil.

    Science.gov (United States)

    2013-08-01

    This study sought to determine the technical feasibility of using seismic techniques to measure the : laboratory and field seismic modulus of lime-stabilized soils (LSS), and to compare/correlate test results : from bench-top (free-free resonance) se...

  4. Influence of stabilizer thickness on over-current test of YBCO-coated conductors

    Science.gov (United States)

    Kwon, N. Y.; Kim, H. S.; Kim, K. L.; Yim, S. W.; Kim, H.-R.; Hyun, O.-B.; Kim, H. M.; Lee, H. G.

    2009-04-01

    The increased use of distributed power generation has led to increasingly high fault current levels. A superconducting fault current limiter (SFCL) is a potential solution to prevent the problem of short-circuit currents. YBCO-coated conductors (CCs) are one of the most promising superconducting materials for SFCLs. Most YBCO CCs have stabilizers, which play a significant role in limiting the fault current in the SFCL. Therefore, the selection of the appropriate material and the thickness of the stabilizer of the CC used for the SFCL may affect its quench/recovery characteristics. In this paper, the quench/recovery characteristics of YBCO CC tapes having stabilizers with various thicknesses were investigated. The quench/recovery test results showed that, as the thickness of the stabilizer decreased, both the final approach temperature and the recovery time decreased.

  5. Flatworm models in pharmacological research: the importance of compound stability testing.

    Science.gov (United States)

    Stalmans, Sofie; Willems, Maxime; Adriaens, Els; Remon, Jean-Paul; D'Hondt, Matthias; De Spiegeleer, Bart

    2014-10-01

    Flatworms possess adult pluripotent stem cells, which make them extraordinary experimental model organisms to assess in vivo the undesirable effects of substances on stem cells. Currently, quality practices, implying evaluation of the stability of the test compound under the proposed experimental conditions, are uncommon in this research field. Nevertheless, performing a stability study during the rational design of in vivo assay protocols will result in more reliable assay results. To illustrate the influence of the stability of the test substance on the final experimental outcome, we performed a short-term International Conference on Harmonization (ICH)-based stability study of cyclophosphamide in the culture medium, to which a marine flatworm model Macrostomum lignano is exposed. Using a validated U(H)PLC method, it was demonstrated that the cyclophosphamide concentration in the culture medium at 20°C is lowered to 80% of the initial concentration after 21days. The multiwell plates, flatworms and diatoms, as well as light exposure, did not influence significantly the cyclophosphamide concentration in the medium. The results of the stability study have practical implications on the experimental set-up of the carcinogenicity assay like the frequency of medium renewal. This case study demonstrates the benefits of applying appropriate quality guidelines already during fundamental research increasing the credibility of the results. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Is lesional stability in vitiligo more important than disease stability for performing surgical interventions? results from a multicentric study

    Directory of Open Access Journals (Sweden)

    Imran Majid

    2016-01-01

    Full Text Available Background: Ensuring stability of the disease process is essential for undertaking surgical intervention in vitiligo. However, there is no consensus regarding the minimum duration of stability or the relative importance of disease and lesional stability in selecting patients for vitiligo grafting. Aim: This multicentric study aims to assess the relative importance of lesional and disease stability on selecting patients for vitiligo grafting. Materials and Methods: One hundred seventy patients were recruited into the study and divided into two groups: Group A with lesional stability of >1 year but overall disease stability of only 6-11 months and Group B with overall disease stability of >1 year. Patients underwent either tissue or cellular vitiligo grafting on the selected lesions and the repigmentation achieved was scored from 0 (no repigmentation to 6 (100% repigmentation. Repigmentation achieved on different sites of the body was compared between the two groups. Adverse effects at both the donor and the recipient sites were also compared. Results: Of the 170 patients who were enrolled, 82 patients were placed in Group A and 88 patients in Group B. Average repigmentation achieved (on scale of 0 to 6 was 3.8 and 4.04 in Group A and Group B, respectively. In Group A, ≥90% repigmentation was achieved in 36.6% (30/82 patients, while 37.5% (33/88 achieved similar results in Group B. Additionally, 47.6% (39/82 and 53.4% (47/88 of cases achieved partial repigmentation in Group A and Group B, respectively. Perigraft halo was the commonest adverse effect observed in both groups. Statistical analysis revealed no significant differences between the two groups with respect to the repigmentation achieved or adverse effects observed. Repigmentation achieved was the best on the face and neck area, while acral areas responded the least. Conclusions: Lesional stability seems to be as relevant as the overall disease stability in selecting patients for

  7. Honeycomb spacer crush stength test results

    Energy Technology Data Exchange (ETDEWEB)

    Leader, D.R.

    1993-09-15

    This report discusses aluminum honeycomb spacers, which are used as an energy absorbent material in shipping packages for off site shipment of radioactive materials and which were ordered in two crush strengths, 1,000 psi and 2,000 psi for use in drop tests requested by the Packaging and Transportation group as part of the shipping container rectification process. Both the group as part of the shipping container rectification process. Both the vendor and the SRTC Materials Laboratory performed crush strength measurements on test samples made from the material used to fabricate the actual spacers. The measurements of crush strength made in the SRTC Materials Laboratory are within 100 psi of the measurements made by the manufacturer for all samples tested and all test measurements are within 10% of the specified crush strength, which is acceptable to the P&T group for the planned tests.

  8. International geomechanical commission. Underground nuclear testing in French Polynesia: stability and hydrology issues

    International Nuclear Information System (INIS)

    1999-01-01

    The International Geomechanical Commission is an independent group of experts in rock mechanics and hydrology. This commission has carried out a study on the rocks stability and hydrology of the atolls of Mururoa and Fangataufa (French Polynesia) after the stoppage of the French underground nuclear tests (147 tests all of all, from which 6 took place in 1995 and 1996). This book presents the results of this study. (J.S.)

  9. Supercritical CO2 test loop operation and first test results

    International Nuclear Information System (INIS)

    Wright, Steven A.; Pickard, Paul S.

    2009-01-01

    The DOE Office of Nuclear Energy is investigating advanced Brayton cycles for use with next generation nuclear power plants. The focus of this work is on the supercritical CO 2 Brayton cycle which has the potential for high efficiency, and for reduced capital costs due to very compact turbomachinery. Sandia has fabricated and is operating a supercritical CO 2 (S-CO 2 ) test loop to investigate the key technology issues associated with this cycle. This loop is part of a multi-year phased development program to develop a megawatt (MW) class closed S-CO 2 Brayton cycle to demonstrate the applicability of this cycle for DOE Gen-IV program. The current loop has been configured as both a compression loop and as simple heated but unrecuperated Brayton cycle. A second split-flow or re-compression Brayton cycle is currently under development that will use approximately 1 MW of heat to run the Brayton cycle. Early configurations of this split-flow Brayton cycle will be operational later this fiscal year. The key issues for this cycle include the fundamental issues of compressor fluid performance and system control near the critical point, but also the supporting technology issues of bearings, sealing technologies, and rotor windage losses which are also essential to achieving efficiency and cost objectives. These tests are providing the first measurements and information on these key supercritical CO 2 power conversion systems questions. Important data for all these issues has been obtained. This report presents the major results of the testing by showing and comparing the measured compressor performance map with the predicted performance. The compression loop uses a ∼50 kWe motor driven compressor to spin a 37 mm OD compressor at design speeds up to 75,000 rpm with a pressure ratio of 1.8 and a flow rate of 3.53 kg/s for a compressor inlet condition of 305.3 K and 7690 kPa. The most recent configuration of this loop has added a small turbine and 260 kW of heater power is

  10. Visual perception skills testing: preliminary results

    CSIR Research Space (South Africa)

    Smith, Andrew C

    2009-02-01

    Full Text Available Good visual perception skills are important in the effective manipulation of Tangible User Interfaces. This paper reports on the application of a test set researchers have developed specifically to quantify the visual perception skills of children...

  11. Evaluation of mid-term stability of night vision tests.

    Science.gov (United States)

    Levy, Y; Glovinsky, Y

    1997-07-01

    Dark adaptation rate, scotopic retinal sensitivity and contrast sensitivity under mesopic conditions, but not visual acuity, have been shown to be directly related to the ability to identify military targets at night. These parameters can be used to select personnel for specific military tasks demanding excellent night vision, as well as to assess pharmacological effects on night vision. To evaluate the mid-term (2 to 6-week period) stability of night vision tests based on assessment of the above parameters. Dark adaptation rate, scotopic retinal sensitivity and contrast sensitivity under mesopic conditions were studied in 16 young volunteers during a 6-week period. Tests of scotopic retinal sensitivity (after 30 min of dark adaptation) exhibited high reproducibility and a low fluctuation rate, with a high correlation between values at week 0 and at 2-week intervals during the following 6 weeks of the study (rs (week 0 to week 6) = 0.81, p = 0.0001). The reproducibility of mesopic contrast sensitivity tests (average of 1.5, 3, 6 and 12 cycles per degree, (cpd)) was fair (rs (week 0 to week 2) = 0.67, p = 0.0045), whereas that of dark adaptation rate tests was poor. In view of the reproducibility characteristics of these night vision tests, assessment of night vision ability in pilots and military personnel, as well as assessment of pharmacological effects on night vision, may be based on scotopic retinal sensitivity (after 30 min of dark adaptation) and contrast sensitivity under mesopic conditions (average of 1.5, 3, 6 and 12 cpd).

  12. 46 CFR 170.185 - Stability test preparations.

    Science.gov (United States)

    2010-10-01

    ... test: (a) The vessel must be as complete as practicable at the time of the test. (b) Each tank vessel...) The water depth at the mooring site must provide ample clearance against grounding. (e) Each mooring... that result in acceptable accuracy in calculating the center of gravity and displacement of the unit...

  13. Stability testing of vaccines: Developing Countries Vaccine Manufacturers' Network (DCVMN) perspective.

    Science.gov (United States)

    Jadhav, Suresh S; Dogar, Vikas; Gautam, Manish; Gairola, Sunil

    2009-11-01

    Stability testing is an integral part of the vaccine manufacturing process and is crucial for the success of immunization programs. WHO (World Health Organization) has recently published guidelines on the stability testing of vaccines. These guidelines enlist scientific basis and principles for stability testing at various stages like development, pre-clinical, clinical, licensing, lot release and post-licensure monitoring. DCVMN (Developing Countries Vaccine Manufacturers' Network) is an international body of developing countries vaccine manufacturers and has viewpoints on technical and administrative issues in stability testing of vaccines. We here highlight viewpoints, possible roles and global expectations of DCVMN in the area of stability testing of vaccines.

  14. Plutonium recycle test reactor characterization activities and results

    Energy Technology Data Exchange (ETDEWEB)

    Cornwell, B.C.

    1997-05-01

    Report contains results of PRTR core and associated structures characterization performed in January and February of 1997. Radiation survey data are presented, along with recommendations for stabilization activities before transitioning to a decontamination and decommissioning function. Recommendations are also made about handling the waste generated by the stabilization activities, and actions suggested by the Decontamination and Decommissioning organization.

  15. A new free-surface stabilization algorithm for geodynamical modelling: Theory and numerical tests

    Science.gov (United States)

    Andrés-Martínez, Miguel; Morgan, Jason P.; Pérez-Gussinyé, Marta; Rüpke, Lars

    2015-09-01

    The surface of the solid Earth is effectively stress free in its subaerial portions, and hydrostatic beneath the oceans. Unfortunately, this type of boundary condition is difficult to treat computationally, and for computational convenience, numerical models have often used simpler approximations that do not involve a normal stress-loaded, shear-stress free top surface that is free to move. Viscous flow models with a computational free surface typically confront stability problems when the time step is bigger than the viscous relaxation time. The small time step required for stability (develop strategies that mitigate the stability problem by making larger (at least ∼10 Kyr) time steps stable and accurate. Here we present a new free-surface stabilization algorithm for finite element codes which solves the stability problem by adding to the Stokes formulation an intrinsic penalization term equivalent to a portion of the future load at the surface nodes. Our algorithm is straightforward to implement and can be used with both Eulerian or Lagrangian grids. It includes α and β parameters to respectively control both the vertical and the horizontal slope-dependent penalization terms, and uses Uzawa-like iterations to solve the resulting system at a cost comparable to a non-stress free surface formulation. Four tests were carried out in order to study the accuracy and the stability of the algorithm: (1) a decaying first-order sinusoidal topography test, (2) a decaying high-order sinusoidal topography test, (3) a Rayleigh-Taylor instability test, and (4) a steep-slope test. For these tests, we investigate which α and β parameters give the best results in terms of both accuracy and stability. We also compare the accuracy and the stability of our algorithm with a similar implicit approach recently developed by Kaus et al. (2010). We find that our algorithm is slightly more accurate and stable for steep slopes, and also conclude that, for longer time steps, the optimal

  16. Test Area North Pool Stabilization Project: Environmental assessment

    International Nuclear Information System (INIS)

    1996-05-01

    The Test Area North (TAN) Pool is located within the fenced TAN facility boundaries on the Idaho National Engineering Laboratory (INEL). The TAN pool stores 344 canisters of core debris from the March, 1979, Three Mile Island (TMI) Unit 2 reactor accident; fuel assemblies from Loss-of-Fluid Tests (LOFT); and Government-owned commercial fuel rods and assemblies. The LOFT and government owned commercial fuel rods and assemblies are hereafter referred to collectively as open-quotes commercial fuelsclose quotes except where distinction between the two is important to the analysis. DOE proposes to remove the canisters of TMI core debris and commercial fuels from the TAN Pool and transfer them to the Idaho Chemical Processing Plant (ICPP) for interim dry storage until an alternate storage location other than at the INEL, or a permanent federal spent nuclear fuel (SNF) repository is available. The TAN Pool would be drained and placed in an industrially and radiologically safe condition for refurbishment or eventual decommissioning. This environmental assessment (EA) identifies and evaluates environmental impacts associated with (1) constructing an Interim Storage System (ISS) at ICPP; (2) removing the TMI and commercial fuels from the pool and transporting them to ICPP for placement in an ISS, and (3) draining and stabilizing the TAN Pool. Miscellaneous hardware would be removed and decontaminated or disposed of in the INEL Radioactive Waste Management Complex (RWMC). This EA also describes the environmental consequences of the no action alternative

  17. Draft environmental assessment -- Test Area North pool stabilization project update

    International Nuclear Information System (INIS)

    1997-06-01

    The purpose of this Environmental Assessment (EA) is to update the ''Test Area North Pool Stabilization Project'' EA (DOE/EA-1050) and finding of no significant impact (FONSI) issued May 6, 1996. This update analyzes the environmental and health impacts of a drying process for the Three Mile Island (TMI) nuclear reactor core debris canisters now stored underwater in a facility on the Idaho National Engineering and Environmental Laboratory (INEEL). A drying process was analyzed in the predecision versions of the EA released in 1995 but that particular process was determined to be ineffective and dropped form the Ea/FONSI issued May 6, 1996. The origin and nature of the TMI core debris and the proposed drying process are described and analyzed in detail in this EA. As did the 1996 EA, this update analyzes the environmental and health impacts of removing various radioactive materials from underwater storage, dewatering these materials, constructing a new interim dry storage facility, and transporting and placing the materials into the new facility. Also, as did the 1996 EA, this EA analyzes the removal, treatment and disposal of water from the pool, and placement of the facility into a safe, standby condition. The entire action would take place within the boundaries of the INEEL. The materials are currently stored underwater in the Test Area North (TAN) building 607 pool, the new interim dry storage facility would be constructed at the Idaho Chemical Processing Plant (ICPP) which is about 25 miles south of TAN

  18. Environmental Assessment -- Test Area North pool stabilization project update

    International Nuclear Information System (INIS)

    1997-08-01

    The purpose of this Environmental Assessment (EA) is to update the ''Test Area North Pool Stabilization Project'' EA (DOE/EA-1050) and finding of no significant impact (FONSI) issued May 6, 1996. This update analyzes the environmental and health impacts of a drying process for the Three Mile Island (TMI) nuclear reactor core debris canisters now stored underwater in a facility on the Idaho National Engineering and Environmental Laboratory (INEEL). A drying process was analyzed in the predecision versions of the EA released in 1995 but that particular process was determined to be ineffective and dropped from the EA/FONSI issued May 6, 1996. A new drying process was subsequently developed and is analyzed in Section 2.1.2 of this document. As did the 1996 EA, this update analyzes the environmental and health impacts of removing various radioactive materials from underwater storage, dewatering these materials, constructing a new interim dry storage facility, and transporting and placing the materials into the new facility. Also, as did the 1996 EA, this EA analyzes the removal, treatment and disposal of water from the pool, and placement of the facility into a safe, standby condition. The entire action would take place within the boundaries of the INEEL. The materials are currently stored underwater in the Test Area North (TAN) building 607 pool, the new interim dry storage facility would be constructed at the Idaho Chemical Processing Plant (ICPP) which is about 25 miles south of TAN

  19. Environmental Assessment -- Test Area North pool stabilization project update

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-08-01

    The purpose of this Environmental Assessment (EA) is to update the ``Test Area North Pool Stabilization Project`` EA (DOE/EA-1050) and finding of no significant impact (FONSI) issued May 6, 1996. This update analyzes the environmental and health impacts of a drying process for the Three Mile Island (TMI) nuclear reactor core debris canisters now stored underwater in a facility on the Idaho National Engineering and Environmental Laboratory (INEEL). A drying process was analyzed in the predecision versions of the EA released in 1995 but that particular process was determined to be ineffective and dropped from the EA/FONSI issued May 6, 1996. A new drying process was subsequently developed and is analyzed in Section 2.1.2 of this document. As did the 1996 EA, this update analyzes the environmental and health impacts of removing various radioactive materials from underwater storage, dewatering these materials, constructing a new interim dry storage facility, and transporting and placing the materials into the new facility. Also, as did the 1996 EA, this EA analyzes the removal, treatment and disposal of water from the pool, and placement of the facility into a safe, standby condition. The entire action would take place within the boundaries of the INEEL. The materials are currently stored underwater in the Test Area North (TAN) building 607 pool, the new interim dry storage facility would be constructed at the Idaho Chemical Processing Plant (ICPP) which is about 25 miles south of TAN.

  20. Draft environmental assessment -- Test Area North pool stabilization project update

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    The purpose of this Environmental Assessment (EA) is to update the ``Test Area North Pool Stabilization Project`` EA (DOE/EA-1050) and finding of no significant impact (FONSI) issued May 6, 1996. This update analyzes the environmental and health impacts of a drying process for the Three Mile Island (TMI) nuclear reactor core debris canisters now stored underwater in a facility on the Idaho National Engineering and Environmental Laboratory (INEEL). A drying process was analyzed in the predecision versions of the EA released in 1995 but that particular process was determined to be ineffective and dropped form the Ea/FONSI issued May 6, 1996. The origin and nature of the TMI core debris and the proposed drying process are described and analyzed in detail in this EA. As did the 1996 EA, this update analyzes the environmental and health impacts of removing various radioactive materials from underwater storage, dewatering these materials, constructing a new interim dry storage facility, and transporting and placing the materials into the new facility. Also, as did the 1996 EA, this EA analyzes the removal, treatment and disposal of water from the pool, and placement of the facility into a safe, standby condition. The entire action would take place within the boundaries of the INEEL. The materials are currently stored underwater in the Test Area North (TAN) building 607 pool, the new interim dry storage facility would be constructed at the Idaho Chemical Processing Plant (ICPP) which is about 25 miles south of TAN.

  1. PEP Support: Laboratory Scale Leaching and Permeate Stability Tests

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Renee L.; Peterson, Reid A.; Rinehart, Donald E.; Buchmiller, William C.

    2010-05-21

    This report documents results from a variety of activities requested by the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The activities related to caustic leaching, oxidative leaching, permeate precipitation behavior of waste as well as chromium (Cr) leaching are: • Model Input Boehmite Leaching Tests • Pretreatment Engineering Platform (PEP) Support Leaching Tests • PEP Parallel Leaching Tests • Precipitation Study Results • Cr Caustic and Oxidative Leaching Tests. Leaching test activities using the PEP simulant provided input to a boehmite dissolution model and determined the effect of temperature on mass loss during caustic leaching, the reaction rate constant for the boehmite dissolution, and the effect of aeration in enhancing the chromium dissolution during caustic leaching. Other tests were performed in parallel with the PEP tests to support the development of scaling factors for caustic and oxidative leaching. Another study determined if precipitate formed in the wash solution after the caustic leach in the PEP. Finally, the leaching characteristics of different chromium compounds under different conditions were examined to determine the best one to use in further testing.

  2. Data Fusion Modeling for an RT3102 and Dewetron System Application in Hybrid Vehicle Stability Testing

    Directory of Open Access Journals (Sweden)

    Zhibin Miao

    2015-08-01

    Full Text Available More and more hybrid electric vehicles are driven since they offer such advantages as energy savings and better active safety performance. Hybrid vehicles have two or more power driving systems and frequently switch working condition, so controlling stability is very important. In this work, a two-stage Kalman algorithm method is used to fuse data in hybrid vehicle stability testing. First, the RT3102 navigation system and Dewetron system are introduced. Second, a modeling of data fusion is proposed based on the Kalman filter. Then, this modeling is simulated and tested on a sample vehicle, using Carsim and Simulink software to test the results. The results showed the merits of this modeling.

  3. Results of Final Focus Test Beam

    Energy Technology Data Exchange (ETDEWEB)

    Walz, Dieter R

    2003-06-13

    The beam experiments of Final Focus Test Beam (FFTB) started in September 1993 at SLAC, and have produced a 1.7 {micro}m x 75 nm spot of 46 GeV electron beam. A number of new techniques involving two nanometer spot-size monitors have been developed. Several beam diagnostic/tuning schemes are applied to achieve and maintain the small spot. This experiment opens the way toward the nanometer world for future linear colliders.

  4. Results of workplace drug testing in Norway

    Directory of Open Access Journals (Sweden)

    Hilde Marie Erøy Lund

    2011-12-01

    Full Text Available Workplace drug testing is less common in Norway than in many other countries. During the period from 2000-2006, 13469 urine or blood samples from employees in the offshore industry, shipping companies and aviation industry were submitted to the Norwegian Institute of Public Health for drug testing. The samples were analysed for benzodiazepines, illicit drugs, muscle relaxants with sedating properties, opioids and z-hypnotics. In total, 2.9% of the samples were positive for one or more substances. During the study period the prevalence decreased for morphine (from 1.9% to 1.1% and increased for amphetamine (from 0.04% to 0.6%, clonazepam (from 0% to 0.1%, methamphetamine (from 0.04% to 0.6%, nitrazepam (from 0% to 0.4% and oxazepam (from 0.5% to 1.3% (p<0.05. There was no significant change in prevalence for the other substances included in the analytical programme. Illicit drugs were significantly associated with lower age (OR: 0.93, p<0.05. This study found low prevalence of drugs among employees in companies with workplace drug testing programmes in Norway.

  5. Methods study of homogeneity and stability test from cerium oxide CRM candidate

    International Nuclear Information System (INIS)

    Samin; Susanna TS

    2016-01-01

    The methods study of homogeneity and stability test from cerium oxide CRM candidate has been studied based on ISO 13258 and KAN DP. 01. 34. The purpose of this study was to select the test method homogeneity and stability tough on making CRM cerium oxide. Prepared 10 sub samples of cerium oxide randomly selected types of analytes which represent two compounds, namely CeO 2 and La 2 O 3 . At 10 sub sample is analyzed CeO 2 and La 2 O 3 contents in duplicate with the same analytical methods, by the same analyst, and in the same laboratory. Data analysis results calculated statistically based on ISO 13528 and KAN DP.01.34. According to ISO 13528 Cerium Oxide samples said to be homogeneous if Ss ≤ 0.3 σ and is stable if | Xr – Yr | ≤ 0.3 σ. In this study, the data of homogeneity test obtained CeO 2 is Ss = 2.073 x 10-4 smaller than 0.3 σ (0.5476) and the stability test obtained | Xr - Yr | = 0.225 and the price is < 0.3 σ. Whereas for La 2 O 3 , the price for homogeneity test obtained Ss = 1.649 x 10-4 smaller than 0.3 σ (0.4865) and test the stability of the price obtained | Xr - Yr | = 0.2185 where the price is < 0.3 σ. Compared with the method from KAN, a sample of cerium oxide has also been homogenized for Fcalc < Ftable and stable, because | Xi - Xhm | < 0.3 x n IQR. Provided that the results of the evaluation homogeneity and stability test from CeO 2 CRM candidate test data were processed using statistical methods ISO 13528 is not significantly different with statistical methods from KAN DP.01.34, which together meet the requirements of a homogeneous and stable. So the test method homogeneity and stability test based on ISO 13528 can be used to make CRM cerium oxide. (author)

  6. Very high stability systems: LMJ target alignment system and MTG imager test setup

    Science.gov (United States)

    Compain, Eric; Maquet, Philippe; Kunc, Thierry; Marque, Julien; Lauer-Solelhac, Maxime; Delage, Laurent; Lanternier, Catherine

    2015-09-01

    Most of space instruments and research facilities require test equipment with demanding opto-mechanical stability. In some specific cases, when the stability performance directly drives the final performance of the scientific mission and when feasibility is questionable, specific methods must be implemented for the associated technical risk management. In present paper, we will present our heritage in terms of methodology, design, test and the associated results for two specific systems : the SOPAC-POS and the MOTA, generating new references for future developments. From a performance point of view, we will emphasis on following key parameters : design symmetry, thermal load management, and material and structural choices. From a method point of view the difficulties arise first during design, from the strong coupling between the thermal, mechanical and optical performance models, and then during testing, from the difficulty of conceiving test setup having appropriate performance level. We will present how these limitations have been overcome. SOPAC-POS is the target alignment system of the LMJ, Laser Mega Joule, the French inertial confinement fusion research center. Its stability has been demonstrated by tests in 2014 after 10 years of research and development activities, achieving 1μm stability @ 6m during one hour periods. MOTA is an Optical Ground Support Equipment aiming at qualifying by tests the Flexible Combined Imager (FCI). FCI is an instrument for the meteorological satellite MTG-I, a program of and funded by the European Space Agency and under prime contractorship of Thales Alenia Space. Optimized design will allow to get better than 0.2 μrad stability for one hour periods, as required for MTF measurement.

  7. Verifiable Measurement-Only Blind Quantum Computing with Stabilizer Testing.

    Science.gov (United States)

    Hayashi, Masahito; Morimae, Tomoyuki

    2015-11-27

    We introduce a simple protocol for verifiable measurement-only blind quantum computing. Alice, a client, can perform only single-qubit measurements, whereas Bob, a server, can generate and store entangled many-qubit states. Bob generates copies of a graph state, which is a universal resource state for measurement-based quantum computing, and sends Alice each qubit of them one by one. Alice adaptively measures each qubit according to her program. If Bob is honest, he generates the correct graph state, and, therefore, Alice can obtain the correct computation result. Regarding the security, whatever Bob does, Bob cannot get any information about Alice's computation because of the no-signaling principle. Furthermore, malicious Bob does not necessarily send the copies of the correct graph state, but Alice can check the correctness of Bob's state by directly verifying the stabilizers of some copies.

  8. Transient and stability tests at Peach Bottom Atomic Power Station Unit 2 at end of Cycle 2

    International Nuclear Information System (INIS)

    Carmichael, L.A.; Niemi, R.O.

    1978-06-01

    Turbine trip transient and low flow stability tests were performed at the Peach Bottom-2 BWR/4 nuclear power plant prior to shutdown for refueling at end of Cycle 2 in April 1977. The results of the turbine trip transient tests showed that the fundamental mode of the acoustical pressure oscillation generated in the main steam piping propagates with relatively little attenuation into the reactor core. The magnitude of the neutron flux transient taking place in the BWR core was found to be strongly affected by the initial rate of pressure rise caused by the pressure oscillation. The measured neutron flux transients showed a strong spatial variation along the axis of the reactor core. Very little radial variation in the neutron flux transient was observed. The low-flow stability tests demonstrated that the Peach Bottom-2 Cycle 2 core exhibited a high degree of stability at the limiting test condition above the rated power-flow control line. The measured reactor stability margins showed the expected sensitivity to core power changes at minimum reactor core flow. The tests showed that the small pressure perturbation stability testing offers a useful and practical method of measuring core stability margins. The actual core stability margin was determined from the measured closed-loop pressure to average neutron flux transfer function data based on maximum likelihood estimates of the parameters in a relatively simple transfer function model determined from nonlinear regression analysis. Both static and dynamic error estimates were taken into consideration in evaluating the test results

  9. AMORE Mo-99 Spike Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Youker, Amanda J. [Argonne National Lab. (ANL), Argonne, IL (United States); Krebs, John F. [Argonne National Lab. (ANL), Argonne, IL (United States); Quigley, Kevin J. [Argonne National Lab. (ANL), Argonne, IL (United States); Byrnes, James P. [Argonne National Lab. (ANL), Argonne, IL (United States); Rotsch, David A [Argonne National Lab. (ANL), Argonne, IL (United States); Brossard, Thomas [Argonne National Lab. (ANL), Argonne, IL (United States); Wesolowski, Kenneth [Argonne National Lab. (ANL), Argonne, IL (United States); Alford, Kurt [Argonne National Lab. (ANL), Argonne, IL (United States); Chemerisov, Sergey [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, George F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-09-27

    With funding from the National Nuclear Security Administrations Material Management and Minimization Office, Argonne National Laboratory (Argonne) is providing technical assistance to help accelerate the U.S. production of Mo-99 using a non-highly enriched uranium (non-HEU) source. A potential Mo-99 production pathway is by accelerator-initiated fissioning in a subcritical uranyl sulfate solution containing low enriched uranium (LEU). As part of the Argonne development effort, we are undertaking the AMORE (Argonne Molybdenum Research Experiment) project, which is essentially a pilot facility for all phases of Mo-99 production, recovery, and purification. Production of Mo-99 and other fission products in the subcritical target solution is initiated by putting an electron beam on a depleted uranium (DU) target; the fast neutrons produced in the DU target are thermalized and lead to fissioning of U-235. At the end of irradiation, Mo is recovered from the target solution and separated from uranium and most of the fission products by using a titania column. The Mo is stripped from the column with an alkaline solution. After acidification of the Mo product solution from the recovery column, the Mo is concentrated (and further purified) in a second titania column. The strip solution from the concentration column is then purified with the LEU Modified Cintichem process. A full description of the process can be found elsewhere [1–3]. The initial commissioning steps for the AMORE project include performing a Mo-99 spike test with pH 1 sulfuric acid in the target vessel without a beam on the target to demonstrate the initial Mo separation-and-recovery process, followed by the concentration column process. All glovebox operations were tested with cold solutions prior to performing the Mo-99 spike tests. Two Mo-99 spike tests with pH 1 sulfuric acid have been performed to date. Figure 1 shows the flow diagram for the remotely operated Mo-recovery system for the AMORE project

  10. OPERA Resistive Plate Chambers underground test results

    International Nuclear Information System (INIS)

    Bergnoli, A.; Brugnera, R.; Candela, A.; Carrara, E.; Ciesielski, R.; Dal Corso, F.; Degli Esposti, L.; Di Giovanni, A.; D'Incecco, M.; Di Troia, C.; Dusini, S.; Fanin, C.; Felici, G.; Gambarara, A.; Garfagnini, A.; Gatta, M.; Grianti, F.; Gustavino, C.; Lindozzi, M.; Longhin, A.; Mengucci, A.; Monacelli, P.; Paoloni, A.; Stanco, L.; Tatananni, E.; Terranova, F.; Spinetti, M.; Stipcevic, M.; Sugonyaev, V.; Terminiello, L.; Ventura, M.; Votano, L.

    2006-01-01

    The OPERA experiment [M. Guler et al., CERN/SPSC 2000-028, SPSC/P318, LNGS P25/2000, July 10, 2000; M. Guler et al., CERN/SPSC 2001-025, SPSC/M668, LNGS-EXP 30/2001 Add. 1/01, August 21, 2001] will study ν μ ->ν τ oscillations through τ appearance on the 732 Km long CERN to Gran Sasso baseline. The magnet yokes of the two muon spectrometers are instrumented with 44 layers of high resistivity bakelite Resistive Plate Chambers (RPCs) operated in streamer mode. Each layer covers about 70 m 2 . Four RPC planes were instrumented and the first tests were performed confirming a good behaviour of the installed RPCs in terms of intrinsic noise and operating currents. The measured noise maps agree with those obtained in the extensive quality tests performed at surface. Counting rates are below 20 Hz/m 2 . Single an multiple cosmic muon tracks were also reconstructed. The estimated efficiency is close to the geometrical limit and the very first measurements of the absolute and differential muon flux are in agreement with expectations

  11. Standard Test Method for Preparing Aircraft Cleaning Compounds, Liquid Type, Water Base, for Storage Stability Testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This test method covers the determination of the stability in storage, of liquid, water-base chemical cleaning compounds, used to clean the exterior surfaces of aircraft. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  12. Tests of a photovoltaic pump: first results

    International Nuclear Information System (INIS)

    Petroselli, A.; Pica, M.; Biondi, P.

    2005-01-01

    The paper deals with a first series of tests conducted in Viterbo (42 deg 25 min North, 12 deg 06 min East) on a PV-DC pump. This series lasted eight months - from the first days of January to the end of August 2003 - and involved measurements of: air and PV-module temperatures; solar radiations, both on horizontal surface and tilted module surface; voltage and intensity of the DC currents from the panel; pump pressures and flow rates. In total, as much as 3,150 data were collected every day. The analysis of the data allowed to obtain some simple empirical relations expressing daily pumped water volumes, instantaneous flow rates and system efficiencies as a function of both radiations and total dynamic heads [it

  13. Experimental results: Pilot plant calcine dissolution and liquid feed stability

    International Nuclear Information System (INIS)

    Herbst, R.S.; Fryer, D.S.; Brewer, K.N.; Johnson, C.K.; Todd, T.A.

    1995-02-01

    The dissolution of simulated Idaho Chemical Processing Plant pilot plant calcines, containing none of the radioactive actinides, lanthanides or fission products, was examined to evaluate the solubility of calcine matrix materials in acidic media. This study was a necessary precursor to dissolution and optimization experiments with actual radionuclide-containing calcines. The importance of temperature, nitric acid concentration, ratio of acid volume to calcine mass, and time on the amount, as a weight percentage of calcine dissolved, was evaluated. These parameters were studied for several representative pilot plant calcine types: (1) Run No. 74 Zirconia calcine; (2) Run No. 17 Zirconia/Sodium calcine; (3) Run No. 64 Zirconia/Sodium calcine; (3) Run No. 1027 Alumina calcine; and (4) Run No. 20 Alumina/Zirconia/Sodium calcine. Statistically designed experiments with the different pilot plant calcines indicated the effect of the studied process variables on the amount of calcine dissolved decreases in the order: Acid/Calcine Ratio > Temperature > HNO 3 Concentration > Dissolution Time. The following conditions are suitable to achieve greater than 90 wt. % dissolution of most Zr, Al, or Na blend calcines: (1) Maximum nitric acid concentration of 5M; (2) Minimum acid/calcine ratio of 10 mL acid/1 gram calcine; (3) Minimum dissolution temperature of 90 degrees C; and (4) Minimum dissolution time of 30 minutes. The formation of calcium sulphate (CaSO 4 ) precipitates was observed in certain dissolved calcine solutions during the dissolution experiments. Consequently, a study was initiated to evaluate if and under what conditions the resulting dissolved calcine solutions would be unstable with regards to precipitate formation. The results indicate that precipitate formation in the calcine solutions prepared under the above proposed dissolution conditions are not anticipated

  14. Stability results of a free air ionization chamber in standard mammography beams

    International Nuclear Information System (INIS)

    Silva, Natalia F.; Xavier, Marcos; Vivolo, Vitor; Caldas, Linda V.E.

    2015-01-01

    Free air ionization chambers are absolute dosimeters, because they can measure basic physical quantities directly without the need of their calibration in a standard radiation beam. They are used for measuring exposure and air kerma in X and gamma radiation beams. The Calibration Laboratory (LCI) of IPEN has a free air ionization chamber of the cylindrical type for low energies. The characterization of this ionization chamber was already performed and reported in a previous study. After a modification in the support of the micrometers used for the movement of the internal cylinder devices, the tests were redone. The objective of this work was to present the new alignment protocol of the free air ionization chamber in low energies of X-ray beams of standard mammography qualities, assuring the positioning reproducibility, and new results of stability tests performed with the application of this protocol will be presented. (author)

  15. Middleware for big data processing: test results

    Science.gov (United States)

    Gankevich, I.; Gaiduchok, V.; Korkhov, V.; Degtyarev, A.; Bogdanov, A.

    2017-12-01

    Dealing with large volumes of data is resource-consuming work which is more and more often delegated not only to a single computer but also to a whole distributed computing system at once. As the number of computers in a distributed system increases, the amount of effort put into effective management of the system grows. When the system reaches some critical size, much effort should be put into improving its fault tolerance. It is difficult to estimate when some particular distributed system needs such facilities for a given workload, so instead they should be implemented in a middleware which works efficiently with a distributed system of any size. It is also difficult to estimate whether a volume of data is large or not, so the middleware should also work with data of any volume. In other words, the purpose of the middleware is to provide facilities that adapt distributed computing system for a given workload. In this paper we introduce such middleware appliance. Tests show that this middleware is well-suited for typical HPC and big data workloads and its performance is comparable with well-known alternatives.

  16. Results on stabilization of nonlinear systems under finite data-rate constraints

    NARCIS (Netherlands)

    Persis, Claudio De

    2004-01-01

    We discuss in this paper a result concerning the stabilization problem of nonlinear systems under data-rate constraints using output feedback. To put the result in a broader context, we shall first review a number of recent contributions on the stabilization problem under data-rate constraints when

  17. Treatment results and long-term stability of anterior open bite malocclusion.

    NARCIS (Netherlands)

    Remmers, D.; Hullenaar, B.W. van 't; Bronkhorst, E.M.; Berge, S.J.; Katsaros, C.

    2008-01-01

    OBJECTIVES: To evaluate treatment results and long-term stability of anterior open bite malocclusion and to identify predictive factors for both treatment results and their stability. DESIGN: Retrospective study. SETTING AND SAMPLE POPULATION: The Department of Orthodontics and Oral Biology at the

  18. Thermal-hydraulic stability tests for newly designed BWR rod bundle (step-III fuel type B)

    International Nuclear Information System (INIS)

    Ito, Y.; Itami, A.; Tsuda, K.; Nakamura, K.; Ishikawa, M.; Toba, A.; Omoto, A.

    2004-01-01

    The Step-III Fuel Type B is a new fuel design for high burn-up operation in BWRs in Japan. The fuel design uses a 9x9 - 9 rod bundle to accommodate the high fuel duty of high burn-up operation and a square water-channel to provide enhanced neutron moderation. The objective of this study is to confirm the thermal-hydraulic stability performance of the new fuel design by tests which simulate the parallel channel configuration of the BWR core. The stability testing was performed at the NFI test loop. The test bundle geometry used for the stability test is a 3x3 heater rod bundle which has about 1/8 of the cross section area of the full size 9x9 - 9 rod bundle. Full size heater rods were used to simulate the fuel rods. For parallel channel simulation, a bypass channel with a 6x6 - 8 heater rod bundle was connected in parallel with the 3x3 rod bundle test channel. The stability test results showed typical flow oscillation features which have been described as density wave oscillations. The stationary limit cycle oscillation extended flow amplitudes to several tens of a percent of the nominal value, during which periodic dry-out and re-wetting were observed. The test results were used for verification of a stability analysis code, which demonstrated that the stability performance of the new fuel design has been conservatively predicted. (author)

  19. Flight Test Experiment Design for Characterizing Stability and Control of Hypersonic Vehicles

    Science.gov (United States)

    Morelli, Eugene A.

    2008-01-01

    A maneuver design method that is particularly well-suited for determining the stability and control characteristics of hypersonic vehicles is described in detail. Analytical properties of the maneuver design are explained. The importance of these analytical properties for maximizing information content in flight data is discussed, along with practical implementation issues. Results from flight tests of the X-43A hypersonic research vehicle (also called Hyper-X) are used to demonstrate the excellent modeling results obtained using this maneuver design approach. A detailed design procedure for generating the maneuvers is given to allow application to other flight test programs.

  20. STABILIZATION AND TESTING OF MERCURY CONTAINING WASTES: BORDEN SLUDGE

    Science.gov (United States)

    This report details the stability assessment of a mercury containing sulfide treatment sludge. Information contained in this report will consist of background data submitted by the geneerator, landfill data supplied by EPA and characterization and leaching studies conducted by UC...

  1. Behavior of Stabilized Peat Soils in Unconfined Compression Tests

    OpenAIRE

    Wong L. Sing; Roslan Hashim; Faisal H. Ali

    2008-01-01

    Problem statement: Deep stabilized peat columns were known to be economical at forming foundations to support highway embankments constructed on deep peat land. However, failure in the formation of the columns with adequate strength was often attributed to unsuitable type and insufficient dosage of binder added to the soil. Organic matter in peat was known to impede the cementing process in the soil, thus retarding the early strength gain of stabilized peat. Approach: To evaluate the strength...

  2. An implementation and test platform for wide area stability assessment methods

    DEFF Research Database (Denmark)

    Wittrock, Martin Lindholm; Jóhannsson, Hjörtur

    2013-01-01

    This paper presents a software platform developed in MatLab with the purpose of supporting research, Development and testing of wide area algorithms for stability assessment and control. The development and testing process of algorithms exploiting real time wide area data from Phasor Measurement...... Units (PMU) can be very time consuming, especially if the testing procedure is not carried out in a systematic and automatic manner. The test platform overcomes this problem by automatically importing system model parameters, topology and simulation output from a time domain simulation of an instability...... scenario and automatically generating synthetic PMU snapshots of the system conditions. To demonstrate the platform’s potential for supporting research and development of wide area algorithms, a method to detect voltage instability is implemented and tested, giving results consistent with results from...

  3. New results on stability analysis of neural networks with time-varying delays

    Energy Technology Data Exchange (ETDEWEB)

    Hua Changchun [Institute of Electrical Engineering, Yanshan University, Qinhuangdao 066004 (China)]. E-mail: cch@ysu.edu.cn; Long Chengnian [Institute of Electrical Engineering, Yanshan University, Qinhuangdao 066004 (China); Guan Xinping [Institute of Electrical Engineering, Yanshan University, Qinhuangdao 066004 (China)

    2006-04-03

    In this Letter the time delay dependent stability problem is investigated for a class of time delay neural networks. By constructing novel Lyapunov Krasovskii functional, we propose the new stability results for time delay neural network. The sufficient conditions obtained in this Letter are looser than those in the former literature. Specially, our results include the time delay independent results obtained in some existing literature. The stability conditions are all in the form of linear matrix inequalities (LMIs), which can be computed and optimized easily. Finally, numerical examples are given to show the superiority of the main results.

  4. Investigation of Long Term Cycle Stability - First Results of Metal Hydride Composites

    OpenAIRE

    Dieterich, Mila; Bürger, Inga; Linder, Marc; Wörner, Antje

    2014-01-01

    Reversible reactions of solid powders and hydrogen can be used for hydrogen storage as well as for thermal applications like heat storages or heat conversion systems. For all applications, one of the fundamental prerequisites is the cycle stability of the reaction material and - if required - its bulk structure. At the Institute of Technical Thermodynamics at the German Aerospace Center a test bench to investigate the cycle stability of reversible gas/solid-reactions has been developed and...

  5. Formulation development and stability testing of oral morphine solution utilizing preformulation approach.

    Science.gov (United States)

    Preechagoon, Detpon; Sumyai, Viroj; Tontisirin, Khanittha; Aumpon, Sirikul; Pongjanyakul, Thaned

    2005-08-18

    Prefomulation approach utilizing the fractional-ordered randomized blocked design was employed for the formulation development and stability testing of morphine solution. Factors expecting to affect the stability of morphine were evaluated, i.e., vehicle, antioxidant, chelating agent, and pH of the solution. Eight formulations of a possible 16 were prepared according to the block design. The stability of the preparations was tested after 35 days of storage. The data of preformulation study were used for formulation development. The presence of glycerin and ethylenediamine-tetraacetic acid in the formulation, and the pH of the solution adjusted to 4, stabilized morphine. The concentration of morphine decreased drastically in the formulations containing sodium metabisulfite, and those pH adjusted to 6. After 35 days, only 65% of morphine was found in the formulation containing sodium metabisulfite and pH adjusted to 6. The results of preformulation study were used for preparing oral morphine preparations. Samples were kept in amber glass bottles and stored at 4 degrees C and 25 degrees C/75% RH for 13 months. No precipitation of the four formulations was detected. Only a decrease of odor and a small increase of pH value of the preparations (preformulation approach. They were stable more than 13 months when stored at 4 degrees C and 25 degrees C/75% RH.

  6. Deformation Monitoring of Geomechanical Model Test and Its Application in Overall Stability Analysis of a High Arch Dam

    Directory of Open Access Journals (Sweden)

    Baoquan Yang

    2015-01-01

    Full Text Available Geomechanical model testing is an important method for studying the overall stability of high arch dams. The main task of a geomechanical model test is deformation monitoring. Currently, many types of deformation instruments are used for deformation monitoring of dam models, which provide valuable information on the deformation characteristics of the prototype dams. However, further investigation is required for assessing the overall stability of high arch dams through analyzing deformation monitoring data. First, a relationship for assessing the stability of dams is established based on the comprehensive model test method. Second, a stability evaluation system is presented based on the deformation monitoring data, together with the relationships between the deformation and overloading coefficient. Finally, the comprehensive model test method is applied to study the overall stability of the Jinping-I high arch dam. A three-dimensional destructive test of the geomechanical model dam is conducted under reinforced foundation conditions. The deformation characteristics and failure mechanisms of the dam abutments and foundation were investigated. The test results indicate that the stability safety factors of the dam abutments and foundation range from 5.2 to 6.0. These research results provide an important scientific insight into the design, construction, and operation stages of this project.

  7. Recrystallization of niobium stabilized ferritic stainless steel during hot rolling simulation by torsion tests

    Directory of Open Access Journals (Sweden)

    Flávia Vieira Braga

    2016-01-01

    Full Text Available The aim of this study was to investigate the effect of finishing hot rolling temperature in promoting interpass recrystallization on a Nb-stabilized AISI 430 ferritic stainless steel. Torsion tests were performed in order to simulate the Steckel mill rolling process by varying the temperature ranges of the finishing passes. Interrupted torsion test were also performed and interpass recrystallization was evaluated via optical microscopy and electron backscatter diffraction (EBSD. As a result of this work, it has been established, within the restrictions of a Steckel mill rolling schedule, which thermomechanical conditions mostly favor SRX.

  8. 49 CFR 199.229 - Reporting of alcohol testing results.

    Science.gov (United States)

    2010-10-01

    ... ALCOHOL TESTING Alcohol Misuse Prevention Program § 199.229 Reporting of alcohol testing results. (a) Each... 49 Transportation 3 2010-10-01 2010-10-01 false Reporting of alcohol testing results. 199.229... alcohol testing results using the Management Information System (MIS) form and instructions as required by...

  9. Interpreting Results from the Standardized UXO Test Sites

    National Research Council Canada - National Science Library

    May, Michael; Tuley, Michael

    2007-01-01

    ...) and the Environmental Security Technology Certification Program (ESCTP) to complete a detailed analysis of the results of testing carried out at the Standardized Unexploded Ordnance (UXO) Test Sites...

  10. Drug and alcohol testing results 2000 annual report

    Science.gov (United States)

    2001-12-01

    The Drug and Alcohol Testing Results 2000 Annual Report is a compilation and analysis of drug and alcohol testing results reported by transit systems in the United State during 2000. The report covers results for the following drug types: marijuana (...

  11. Drug and alcohol testing results 1999 annual report

    Science.gov (United States)

    2000-12-01

    The Drug and Alcohol Testing Results 1999 Annual Report is a compilation and analysis of drug and alcohol testing results reported by transit systems in the United States during 1999. The report covers results for the following drug types: marijuana ...

  12. Drug and alcohol testing results 1998 annual report

    Science.gov (United States)

    1999-12-01

    The Drug and Alcohol Testing Results 1998 Annual Report is a compilation and analysis of drug and alcohol testing results reported by transit systems in the United States during 1998. The report covers results for the following drug types: marijuana ...

  13. Biomechanical testing of a polymer-based biomaterial for the restoration of spinal stability after nucleotomy

    Directory of Open Access Journals (Sweden)

    Kaps Christian

    2009-07-01

    Full Text Available Abstract Background Surgery for disc herniations can be complicated by two major problems: painful degeneration of the spinal segment and re-herniation. Therefore, we examined an absorbable poly-glycolic acid (PGA biomaterial, which was lyophilized with hyaluronic acid (HA, for its utility to (a re-establish spinal stability and to (b seal annulus fibrosus defects. The biomechanical properties range of motion (ROM, neutral zone (NZ and a potential annulus sealing capacity were investigated. Methods Seven bovine, lumbar spinal units were tested in vitro for ROM and NZ in three consecutive stages: (a intact, (b following nucleotomy and (c after insertion of a PGA/HA nucleus-implant. For biomechanical testing, spinal units were mounted on a loading-simulator for spines. In three cycles, axial loading was applied in an excentric mode with 0.5 Nm steps until an applied moment of ± 7.5 Nm was achieved in flexion/extension. ROM and NZ were assessed. These tests were performed without and with annulus sealing by sewing a PGA/HA annulus-implant into the annulus defect. Results Spinal stability was significantly impaired after nucleotomy (p Conclusion PGA/HA biomaterial seems to be well suited for cell-free and cell-based regenerative treatment strategies in spinal surgery. Its abilities to restore spinal stability and potentially close annulus defects open up new vistas for regenerative approaches to treat intervertebral disc degeneration and for preventing implant herniation.

  14. Stability Testing of a Wide Bone-Anchored Device after Surgery without Skin Thinning

    Directory of Open Access Journals (Sweden)

    Malou Hultcrantz

    2015-01-01

    Full Text Available Objective. To longitudinally follow the osseointegration using Resonance Frequency Analysis (RFA for different lengths of abutment on a new wide bone-anchored implant, introduced with the non-skin thinning surgical technique. Study Design. A single-center, prospective 1 year study following adults with bone-anchored hearing implants. Materials and Methods. Implantation was performed and followed for a minimum of 1 year. All patients were operated on according to the tissue preserving technique. A 4.5 mm wide fixture (Oticon Medical with varying abutments (9 to 12 mm was used and RFA was tested 1 week, 7 weeks, 6 months, and 12 months later. Implant Stability Quotient (ISQ, was measured from 1 to 100. Stability was compared to a group of patients (N=7 implanted with another brand (Cochlear BI400 of 4.5 mm fixtures. Results. All 10 adults concluded the study. None of the participants lost their implant during the test period indicating a good anchoring of abutments to the wide fixture tested. Stability testing was shown to vary depending on abutment length and time after surgery and with higher values for shorter abutments and increasing values over the first period of time. One patient changed the abutment from 12 to 9 mm and another from a 9 to a 12 during the year. No severe skin problems, numbness around the implant, or cosmetic problems arose. Conclusion. After 1 year of follow-up, combination of a wide fixture implant and the non-skin thinning surgical technique indicates a safe procedure with good stability and no abutment losses.

  15. Environmental effects on vertebrate species richness: testing the energy, environmental stability and habitat heterogeneity hypotheses.

    Directory of Open Access Journals (Sweden)

    Zhenhua Luo

    Full Text Available BACKGROUND: Explaining species richness patterns is a central issue in biogeography and macroecology. Several hypotheses have been proposed to explain the mechanisms driving biodiversity patterns, but the causes of species richness gradients remain unclear. In this study, we aimed to explain the impacts of energy, environmental stability, and habitat heterogeneity factors on variation of vertebrate species richness (VSR, based on the VSR pattern in China, so as to test the energy hypothesis, the environmental stability hypothesis, and the habitat heterogeneity hypothesis. METHODOLOGY/PRINCIPAL FINDINGS: A dataset was compiled containing the distributions of 2,665 vertebrate species and eleven ecogeographic predictive variables in China. We grouped these variables into categories of energy, environmental stability, and habitat heterogeneity and transformed the data into 100 × 100 km quadrat systems. To test the three hypotheses, AIC-based model selection was carried out between VSR and the variables in each group and correlation analyses were conducted. There was a decreasing VSR gradient from the southeast to the northwest of China. Our results showed that energy explained 67.6% of the VSR variation, with the annual mean temperature as the main factor, which was followed by annual precipitation and NDVI. Environmental stability factors explained 69.1% of the VSR variation and both temperature annual range and precipitation seasonality had important contributions. By contrast, habitat heterogeneity variables explained only 26.3% of the VSR variation. Significantly positive correlations were detected among VSR, annual mean temperature, annual precipitation, and NDVI, whereas the relationship of VSR and temperature annual range was strongly negative. In addition, other variables showed moderate or ambiguous relations to VSR. CONCLUSIONS/SIGNIFICANCE: The energy hypothesis and the environmental stability hypothesis were supported, whereas little

  16. Exponential stability result for discrete-time stochastic fuzzy uncertain neural networks

    International Nuclear Information System (INIS)

    Mathiyalagan, K.; Sakthivel, R.; Marshal Anthoni, S.

    2012-01-01

    This Letter addresses the stability analysis problem for a class of uncertain discrete-time stochastic fuzzy neural networks (DSFNNs) with time-varying delays. By constructing a new Lyapunov–Krasovskii functional combined with the free weighting matrix technique, a new set of delay-dependent sufficient conditions for the robust exponential stability of the considered DSFNNs is established in terms of Linear Matrix Inequalities (LMIs). Finally, numerical examples with simulation results are provided to illustrate the applicability and usefulness of the obtained theory. -- Highlights: ► Applications of neural networks require the knowledge of dynamic behaviors. ► Exponential stability of discrete-time stochastic fuzzy neural networks is studied. ► Linear matrix inequality optimization approach is used to obtain the result. ► Delay-dependent stability criterion is established in terms of LMIs. ► Examples with simulation are provided to show the effectiveness of the result.

  17. The stability of clay using mount Sinabung ash with unconfined compression test (uct) value

    Science.gov (United States)

    Puji Hastuty, Ika; Roesyanto; Hutauruk, Ronny; Simanjuntak, Oberlyn

    2018-03-01

    The soil has a important role as a highway’s embankment material (sub grade). Soil conditions are very different in each location because the scientifically soil is a very complex and varied material and the located on the field is very loose or very soft, so it is not suitable for construction, then the soil should be stabilized. The additive material commonly used for soil stabilization includes cement, lime, fly ash, rice husk ash, and others. This experiment is using the addition of volcanic ash. The purpose of this study was to determine the Index Properties and Compressive Strength maximum value with Unconfined Compression Test due to the addition of volcanic ash as a stabilizing agent along with optimum levels of the addition. The result showed that the original soil sample has Water Content of 14.52%; the Specific Weight of 2.64%; Liquid limit of 48.64% and Plasticity Index of 29.82%. Then, the Compressive Strength value is 1.40 kg/cm2. According to USCS classification, the soil samples categorized as the (CL) type while based on AASHTO classification, the soil samples are including as the type of A-7-6. After the soil is stabilized with a variety of volcanic ash, can be concluded that the maximum value occurs at mixture variation of 11% Volcanic Ash with Unconfined Compressive Strength value of 2.32 kg/cm2.

  18. New results on global exponential stability of recurrent neural networks with time-varying delays

    International Nuclear Information System (INIS)

    Xu Shengyuan; Chu Yuming; Lu Junwei

    2006-01-01

    This Letter provides new sufficient conditions for the existence, uniqueness and global exponential stability of the equilibrium point of recurrent neural networks with time-varying delays by employing Lyapunov functions and using the Halanay inequality. The time-varying delays are not necessarily differentiable. Both Lipschitz continuous activation functions and monotone nondecreasing activation functions are considered. The derived stability criteria are expressed in terms of linear matrix inequalities (LMIs), which can be checked easily by resorting to recently developed algorithms solving LMIs. Furthermore, the proposed stability results are less conservative than some previous ones in the literature, which is demonstrated via some numerical examples

  19. Fractional Differential Equations in Terms of Comparison Results and Lyapunov Stability with Initial Time Difference

    Directory of Open Access Journals (Sweden)

    Coşkun Yakar

    2010-01-01

    Full Text Available The qualitative behavior of a perturbed fractional-order differential equation with Caputo's derivative that differs in initial position and initial time with respect to the unperturbed fractional-order differential equation with Caputo's derivative has been investigated. We compare the classical notion of stability to the notion of initial time difference stability for fractional-order differential equations in Caputo's sense. We present a comparison result which again gives the null solution a central role in the comparison fractional-order differential equation when establishing initial time difference stability of the perturbed fractional-order differential equation with respect to the unperturbed fractional-order differential equation.

  20. Surrounding rock mass stability monitoring of underground caverns in a geomechanical model test using FBG sensors

    Science.gov (United States)

    Li, Yong; Zhu, Weishen; Zheng, Wenhua; He, Jianping

    2009-07-01

    Fiber Bragg Gratings (FBG) sensor is widely accepted as a structural stability device for all kinds of geomaterials by either embedding into or bonding onto the structures. The physical model in geotechnical engineering, which can accurately simulate the construction processes and the effects on the stability of underground caverns on basis of satisfying the similarity principles, is an actual physical entity. Due to a large number of restrained factors, a series of experiments are difficult to be carried out, in particular for how to obtain physical parameters during the experiments. Using the geo-mechanical model test of underground caverns in Shuangjiangkou Hydropower Station as a research object, the FBG sensors were mainly focused on and adopted to figure out the problem how to achieve the small displacements in the large-scale model test. The final experimental results show that the FBG sensor has higher measuring accuracy than other conventional sensors like strain gages and mini-extensometers. The experimental results agree well with the numerical simulation results. In the process of building the model, it's successful to embed the FBG sensors in the physical model through making a reserved pore and adding some special glue. In conclusion, FBG sensors can effectively measure the small displacement of monitoring points in the whole process of the geomechanical model test. The experimental results reveal the deformation and failure characteristics of the surrounding rock mass and make some guidance for the in-situ engineering construction.

  1. MATISSE: alignment, integration, and test phase first results

    Science.gov (United States)

    Allouche, F.; Robbe-Dubois, S.; Lagarde, S.; Cruzalèbes, P.; Antonelli, P.; Bresson, Y.; Fantei-Caujolle, Y.; Marcotto, A.; Morel, S.; Beckmann, U.; Bettonvil, F.; Berio, Ph.; Heininger, M.; Lehmitz, M.; Agocs, T.; Brast, R.; Elswijk, E.; Ives, D.; Meixner, K.; Laun, W.; Mellein, M.; Neumann, U.; Bailet, C.; Clausse, J.-M.; Matter, A.; Meilland, A.; Millour, F.; Petrov, R. G.; Accardo, M.; Bristow, P.; Frahm, R.; Glindemann, A.; Gonzáles Herrera, J.-C.; Lizon, J.-L.; Schöller, M.; Graser, U.; Jaffe, W.; Lopez, B.

    2016-08-01

    MATISSE (Multi AperTure mid-Infrared SpectroScopic Experiment) is the spectro-interferometer for the VLTI of the European Southern Observatory, operating in near and mid-infrared, and combining up to four beams from the unit or the auxiliary telescopes. MATISSE will offer new breakthroughs in the study of circumstellar environments by allowing the multispectral mapping of the material distribution, the gas and essentially the dust. The instrument consists in a warm optical system (WOP) accepting four optical beams and relaying them after a dichroic splitting (for the L and M- and N- spectral bands) to cold optical benches (COB) located in two separate cryostats. The Observatoire de la Côte d'Azur is in charge of the WOP providing the spectral band separation, optical path equalization and modulation, pupil positioning, beam anamorphosis, beam commutation, and calibration. NOVA-ASTRON is in charge of the COB providing the functions of beam selection, reduction of thermal background emission, spatial filtering, pupil transfer, photometry and interferometry splitting, additional beam anamorphosis, spectral filtering, polarization selection, image dispersion, and image combination. The Max Planck Institut für Radio Astronomie is in charge of the operation and performance validation of the two detectors, a HAWAII-2RG from Teledyne for the L- and M- bands and a Raytheon AQUARIUS for the N-band. Both detectors are provided by ESO. The Max Planck Institut für Astronomie is in charge of the electronics and the cryostats for which the requirements on space limitations and vibration stability resulted on very specific and stringent decisions on the design. The integration and test of the COB: the two cryogenic systems, including the cold benches and the detectors, have been conducted at MPIA in parallel with the integration of the WOP at OCA. At the end of 2014, the complete instrument was integrated at OCA. Following this integration, a period of interface and alignment

  2. Revisiting test stability: further evidence relating to the measurement ...

    African Journals Online (AJOL)

    In several earlier analyses of two tests of academic literacy – the Test of Academic Literacy Levels (TALL) and its Afrikaans counterpart, the Toets vir Akademiese Geletterdheidsvlakke (TAG) – we have adopted an approach to the problem that tests may be abused (and therefore used to harm people) by discussing various ...

  3. Laboratory tests of the response stability of the ATLAS Tile Calorimeter photomultipliers

    Science.gov (United States)

    Kazanin, V. F.

    2017-09-01

    High performance stability of the ATLAS Tile Calorimeter is achieved with a procedure including a multi-step calibration. One step of the calibration is based on measurements of the response stability to laser excitation of the PMTs that are used to read out the calorimeter cells. A facility to study the performance of the PMT stability response has been operating in the PISA-INFN laboratories since 2015. Goals of the tests are to study the time evolution of the PMT response in order to reproduce and understand the origin of the response drifts observed with the Tile Calorimeter PMTs during LHC Run I and Run II. A new statistical approach was used to measure the drift of the absolute PMT gain. A new procedure which combines studies of the time evolution of the global PMT responses and of the individual PMT gains was adopted to derive the evolution of the cathode quantum efficiency. The experimental setup of the Pisa facility and the first results obtained by testing about 30 PMTs are presented.

  4. Surface stability and small-scale testing of zirconia

    OpenAIRE

    Camposilvan, Erik

    2015-01-01

    Tesi per compendi de publicacions. La consulta íntegra de la tesi, inclosos els articles no comunicats públicament per drets d'autor, es pot realitzar prèvia petició a l'Arxiu UPC Tetragonal polycrystalline zirconia stabilized with 3 mol% of yttria (3Y-TZP) is a biocompatible ceramic showing superior mechanical properties, which are partly the consequence of phase transformation: the tetragonal metastable phase can transform, with a net volume increase, to the stable monoclinic phase by a ...

  5. Irradiation effects test series, test IE-5. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Croucher, D. W.; Yackle, T. R.; Allison, C. M.; Ploger, S. A.

    1978-01-01

    Test IE-5, conducted in the Power Burst Facility at the Idaho National Engineering Laboratory, employed three 0.97-m long pressurized water reactor type fuel rods, fabricated from previously irradiated zircaloy-4 cladding and one similar rod fabricated from unirradiated cladding. The objectives of the test were to evaluate the influence of simulated fission products, cladding irradiation damage, and fuel rod internal pressure on pellet-cladding interaction during a power ramp and on fuel rod behavior during film boiling operation. The four rods were subjected to a preconditioning period, a power ramp to an average fuel rod peak power of 65 kW/m, and steady state operation for one hour at a coolant mass flux of 4880 kg/s-m/sup 2/ for each rod. After a flow reduction to 1800 kg/s-m/sup 2/, film boiling occurred on one rod. Additional flow reductions to 970 kg/s-m/sup 2/ produced film boiling on the three remaining fuel rods. Maximum time in film boiling was 80s. The rod having the highest initial internal pressure (8.3 MPa) failed 10s after the onset of film boiling. A second rod failed about 90s after reactor shutdown. The report contains a description of the experiment, the test conduct, test results, and results from the preliminary postirradiation examination. Calculations using a transient fuel rod behavior code are compared with the test results.

  6. Legal provisions governing the acknowledgement of test results

    International Nuclear Information System (INIS)

    Strecker, A.

    1982-01-01

    The legal provisions governing the acknowledgment of test results are most frequently applied by administrative orders (design and qualification approvals or specimen testing and approval) and are thus claimable and voidable in accordance with general administrative law. The acknowledgment of test certificates requires a legal basis. Test results, however, can be acknowledged also by administrative bodies. Recently, the Federal Government began to delegate more of its legal authority in this field to private institutions, allowing test results to be acknowledged and test certificates to be issued by government controlled private institutions. (orig.) [de

  7. Legal provisions governing the acknowledgment of test results

    International Nuclear Information System (INIS)

    Strecker, A.

    1982-01-01

    The legal provisions governing the acknowledgment of test results are most frequently applied by administrative orders (design and qualification approvals or specimen testing and approval) and are thus claimable and voidable in accordance with general administrative law. The acknowledgment of test certificates requires a legal basis. Test results, however, can be acknowledged also by administrative bodies. Recently, the Federal Government began to delegate more of its legal authority in this field to private institutions, allowing test results to be acknowledged and test certificates to be issued by government controlled private institutions. (orig.) [de

  8. New test methods for BIPV. Results from IP performance

    International Nuclear Information System (INIS)

    Jol, J.C.; Van Kampen, B.J.M.; De Boer, B.J.; Reil, F.; Geyer, D.

    2009-11-01

    Within the Performance project new test procedures for PV building products and the building performance as a whole when PV is applied in buildings have been drafted. It has resulted in a first draft of new test procedures for PV building products and proposals for tests for novel BIPV technology like thin film. The test proposed are a module breakage test for BIPV products, a fire safety test for BIPV products and a dynamic load test for BIPV products. Furthermore first proposals of how flexible PV modules could be tested in an appropriate way to ensure long time quality and safety of these new products are presented.

  9. Simple test for physical stability of cryogenic tank insulation

    Science.gov (United States)

    Rossello, D.

    1968-01-01

    Qualitative test determines the ability of insulation liners used on liquid hydrogen tanks to withstand stresses produced by the thermal shocks imparted to the insulation during tank filling and drainage. Test specimens are bonded to metal plates with a low thermal expansion coefficient and are immersed in liquid hydrogen.

  10. Drug and alcohol testing results : 1997 annual report

    Science.gov (United States)

    1998-12-01

    The Drug and Alcohol Testing Results 1997 Annual Report is a compilation and analysis of mass transit drug and alcohol testing reported by transit systems in the United States during 1997. The report covers testing results for the following drug type...

  11. Chemical interaction of radioactive waste with clay engineered barriers: stability of the resulting immobilizer phase

    International Nuclear Information System (INIS)

    Galunin, Evgeny; Vidal, Miquel; Alba, Maria D.

    2010-01-01

    calcination at 1300 deg. C for 24 h, to form the β-polymorph, in some case it was accompanied by minor phase such as oxide, REE 2 O 3 , or the oxy-orthosilicate, REE 2 SiO 5 . Subsequently, the di-silicates were submitted to a standardized leaching test at a controlled pH (CEN/TS 14429 pH stat test, in the pH range of 1-13, and the di-silicate phase persistence was quantified in the whole pH range. While the rate of REE and Si leaching were quantified by using ICP-OES, the potential transformation of the crystalline and amorphous phases was followed by X-ray diffraction, solid state nuclear magnetic resonance, and scanning electron microscopy, by the analyses of di-silicate samples before and after the application of the leaching test. The pH stat leaching curves of the respective REE and Si for the three di-silicates informed on the di-silicate stability with changing pH, are shown (leaching curves for Sc, Lu and Y and leaching curves for Si). In general, the leaching curve shapes were similar among for the REE. The highest leaching rates were obtained at acid pH (especially for Lu 2 Si 2 O 7 and Y 2 Si 2 O 7 di-silicates), and they decreased drastically to negligible values at basic pH. Among the REE investigated, Sc, with the smallest ionic radius, had the lowest leaching rates over the whole pH range, while Y, with the largest ionic radius, had the highest ones, while Lu showed an intermediate behaviour. These results agree with previous data reported in the literature, in which it was already observed that the stability range of the β-polymorph increased as the ionic radius of the rare earth diminishes. The same pH dependence was observed for Si, with the leaching rate values being lower than for the corresponding REE. The structural analysis demonstrated that the amount of crystalline phase remained almost constant at pH > 3, and that new phases were not generated in the pH range examined. From the results obtained it is possible to conclude that the di-silicate phase

  12. New stability and boundedness results to Volterra integro-differential equations with delay

    Directory of Open Access Journals (Sweden)

    Cemil Tunç

    2016-04-01

    Full Text Available In this paper, we consider a certain non-linear Volterra integro-differential equations with delay. We study stability and boundedness of solutions. The technique of proof involves defining suitable Lyapunov functionals. Our results improve and extend the results obtained in literature.

  13. Drug and alcohol testing results 1996 annual report

    Science.gov (United States)

    1997-12-01

    The report is a compilation and analysis of mass transit drug and alcohol testing reported by transit systems in the United States during 1996. The report covers testing results for the following drug types: marijuana (THC), cocaine, phencyclidine (P...

  14. Results from the 2013 drug and alcohol testing survey.

    Science.gov (United States)

    2015-12-01

    This report summarizes the results of the 2013 Federal Motor Carrier Safety Administration (FMCSA) Drug and Alcohol Testing Survey. This annual survey measures the percentage of drivers with commercial drivers licenses (CDLs) that test positive fo...

  15. Results from the 2008 Drug and Alcohol Testing Survey

    Science.gov (United States)

    2010-01-01

    This report summarizes the results of the 2008 Federal Motor Carrier Safety Administration Drug and Alcohol Testing Survey. This annual survey measures the percentage of drivers with commercial drivers licenses who test positive for controlled sub...

  16. Stability results for stochastic delayed recurrent neural networks with discrete and distributed delays

    Science.gov (United States)

    Chen, Guiling; Li, Dingshi; Shi, Lin; van Gaans, Onno; Verduyn Lunel, Sjoerd

    2018-03-01

    We present new conditions for asymptotic stability and exponential stability of a class of stochastic recurrent neural networks with discrete and distributed time varying delays. Our approach is based on the method using fixed point theory, which do not resort to any Liapunov function or Liapunov functional. Our results neither require the boundedness, monotonicity and differentiability of the activation functions nor differentiability of the time varying delays. In particular, a class of neural networks without stochastic perturbations is also considered. Examples are given to illustrate our main results.

  17. Space shuttle maneuvering engine reusable thrust chamber program. Task 11: Low Epsilon stability test plan

    Science.gov (United States)

    Pauckert, R. P.

    1974-01-01

    The performance and heat transfer characteristics of a doublet element type injector for the space shuttle orbiter maneuvering engine thrust chamber were investigated. Ths stability characteristics were evaluated over a range of chamber pressures and mixture ratios. The specific objectives of the test were: (1) to determine whether stability has been influenced by injection of boundary layer coolant across the cavity entrance, (2) if the injector is stable, to determine the minimum cavity area required to maintain stability, and (3) if the injector is unstable, to determine the effects of entrance geometry and increased area on stability.

  18. Investigations of blood ammonia analysis: Test matrices, storage, and stability.

    Science.gov (United States)

    Goldstein, Brittany N; Wesler, Jordan; Nowacki, Amy S; Reineks, Edmunds; Natowicz, Marvin R

    2017-06-01

    An assessment of blood ammonia concentration is common medical practice in the evaluation of an individual with an unexplained mental status change or coma. The determination of a blood ammonia level is most commonly done using a glutamate dehydrogenase (GLDH)-based assay, although there are many potential sources of artifact and the literature is inconsistent regarding key preanalytic issues. Using a GLDH-based assay, we first investigated matrix effects using three anticoagulants: heparin, EDTA and oxalate. Heparin-anticoagulated plasma was substantially less precise than EDTA- and oxalate-anticoagulated plasma. Oxalate-anticoagulated plasma showed a greater baseline of apparent ammonia than either heparin- or EDTA-derived plasma, presumably due to interferants. We then evaluated the stability of EDTA-anticoagulated plasma for assessment of ammonia when stored at 4°C,-14°C or -70°C. There was a linear increase of ammonia with storage at both 4°C and -14°C. Plasma kept at -70°C for up to three weeks showed no change in measured ammonia relative to the baseline determination. This work clarifies preanalytic conditions for which a precise determination of ammonia can be accomplished using a GLDH-based assay. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Stability results for the parameter identification inverse problem in cardiac electrophysiology

    Science.gov (United States)

    Lassoued, Jamila; Mahjoub, Moncef; Zemzemi, Néjib

    2016-11-01

    In this paper we prove a stability estimate of the parameter identification problem in cardiac electrophysiology modeling. We use the monodomain model which is a reaction diffusion parabolic equation where the reaction term is obtained by solving an ordinary differential equation (ODE). We are interested in proving the stability of the identification of the parameter {τ }{in}, which is the parameter that multiplies the cubic term in the reaction term. The proof of the result is based on a new Carleman-type estimate for both partial differential equation (PDE) and ODE problems. As a consequence of the stability result we prove the uniqueness of the parameter {τ }{in} giving some observations of both state variables at a given time t 0 in the whole domain and in the PDE variable in a non empty open subset w 0 of the domain.

  20. Irradiation Effects Test Series: Test IE-2. Test results report. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Allison, C. M.; Croucher, D. W.; Ploger, S. A.; Mehner, A. S.

    1977-08-01

    The report describes the results of a test using four 0.97-m long PWR-type fuel rods with differences in diametral gap and cladding irradiation. The objective of this test was to provide information about the effects of these differences on fuel rod behavior during quasi-equilibrium and film boiling operation. The fuel rods were subjected to a series of preconditioning power cycles of less than 30 kW/m. Rod powers were then increased to 68 kW/m at a coolant mass flux of 4900 kg/s-m/sup 2/. After one hour at 68 kW/m, a power-cooling-mismatch sequence was initiated by a flow reduction at constant power. At a flow of 2550 kg/s-m/sup 2/, the onset of film boiling occurred on one rod, Rod IE-011. An additional flow reduction to 2245 kg/s-m/sup 2/ caused the onset of film boiling on the remaining three rods. Data are presented on the behavior of fuel rods during quasiequilibrium and during film boiling operation. The effects of initial gap size, cladding irradiation, rod power cycling, a rapid power increase, and sustained film boiling are discussed. These discussions are based on measured test data, preliminary postirradiation examination results, and comparisons of results with FRAP-T3 computer model calculations.

  1. Integrated leak rate test results of JOYO reactor containment vessel

    International Nuclear Information System (INIS)

    Tamura, M.; Endo, J.

    1982-02-01

    Integrated leak rate tests of JOYO after the reactor coolant system had been filled with sodium have been performed two times since 1978 (February 1978 and December 1979). The tests were conducted with the in-containment sodium systems, primary argon cover gas system and air conditioning systems operating. Both the absolute pressure method and the reference chamber method were employed during the test. The results of both tests confirmed the functioning of the containment vessel, and leak rate limits were satisfied. In Addition, the adequancy of the test instrumentation system and the test method was demonstrated. Finally the plant conditions required to maintain reasonable accuracy for the leak rate testing of LMFBR were established. In this paper, the test conditions and the test results are described. (author)

  2. Tube suction test for evaluating durability of cementitiously stabilized soils.

    Science.gov (United States)

    2011-06-01

    In a comprehensive laboratory study, different tests namely, unconfined compressive strength (UCS) at the end of freeze-thaw/wet-dry (F-T/W-D) cycles, resilient modulus (Mr) at the end of F-T/W-D cycles, vacuum saturation, tube suction, and moisture ...

  3. Environmental Stability Testing of a Coated, Elastomeric Dental Ribbon.

    Science.gov (United States)

    1979-09-01

    soe or " esa PWXZ S 16CURITV CLASIFICATION OF THIS PAGR(Ihusa t Eftmem percent) respectively.) Modulus were 5.0,0.18, 0.14 and 0.08 (xl05 p.s.i...lengths were measured with a steel ruler (to 0.01 inch). **Conditioning Specimens tested at temperatures above and below roo. temperature were conditioned

  4. Test of Cable Products in Respect of Thermal and Dynamic Stability

    Directory of Open Access Journals (Sweden)

    M. A. Коrotkevich

    2010-01-01

    Full Text Available The paper considers conditions for selection of  power supply of the unit which is used for testing samples of cable products by thermal and dynamic stability currents. It has been shown that while conducting testing by thermal and dynamic stability currents at nominal cable voltage it is more justifiable to use a percussive energy accumulator, and in the case when the voltage is low an inductive energy accumulator is used.

  5. Arsenic stability in arsenopyrite-rich cemented paste backfills: a leaching test-based assessment.

    Science.gov (United States)

    Coussy, Samuel; Benzaazoua, Mostafa; Blanc, Denise; Moszkowicz, Pierre; Bussière, Bruno

    2011-01-30

    Arsenic (As) is a toxicant in tailings from sulphur deposits. It represents an environmental risk because of its high solubility. Tailings can be mixed with water (typically 25%) and a low proportion of hydraulic binder (3-7%) to produce a cemented paste backfill (CPB), stored in underground mine openings. CPB is a tailings storage technique, but it could also provide environmental advantages by stabilization of polluting elements such as As. Tailings from Casa Berardi mine (QC, Canada) contain As (3800 ppm), mainly in arsenopyrite form. For this study, three different CPBs were synthesized in laboratory using Casa Berardi tailings and three different binders. These pastes were submitted to various leaching tests after 28 days of curing. The results indicate that As is released at higher concentration for a fly ash-based CPB than for slag- and Portland cement-based CPB. However, at lower pH, As is better stabilized in fly ash-based samples. These differences can be explained by a variation of solubility of As-compounds in each CPB. Several mechanisms of As release occur, as diffusion and/or dissolution/precipitation. The accelerated weathering test results show that sulphide reactivity is buffered by the neutralizing minerals contained in CPB, and influence the As release behaviour by decreasing the oxidation of As-bearing sulphides. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. Relationship between ultrasonic pulse velocity test result and ...

    African Journals Online (AJOL)

    The third stage subjected the samples to UPV and destructive tests at the end of the following curing days: 1, 3, 7, 14, 21, 28, 56 and 90 days. Ultrasonic Pulse Velocity test result showed an inverse relationship (of -0.935) with the crushed concrete compressive strength. Correlation test, multiple regression analysis, graphs ...

  7. Stability results for a reaction-diffusion system with a single measurement

    Energy Technology Data Exchange (ETDEWEB)

    Ramoul, Hichem [Centre universitaire de Khenchela, Route de Batna, BP 1252, Liberte, 40004 Khenchela (Algeria); Gaitan, Patricia [Laboratoire d' analyse, topologie, probabilites CNRS UMR 6632, Marseille (France) and Universite Aix-Marseille II (France); Cristofol, Michel [Laboratoire d' analyse, topologie, probabilites CNRS UMR 6632, Marseille, France and Universite Aix-Marseille III (France)

    2007-06-15

    For a two by two reaction-diffusion system on a bounded domain we give a simultaneous stability result for one coefficient and for the initial conditions. The key ingredient is a global Carleman-type estimate with a single observation acting on a subdomain.

  8. Production Facility Prototype Blower 1000 Hour Test Results II

    Energy Technology Data Exchange (ETDEWEB)

    Wass, Alexander Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2018-01-08

    Long duration tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks were not included in these tests. Five 1000 hour tests have been completed since the first test was performed in January of 2016. All five 1000 hour tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for each test, including a review of the first and second tests, are included in this report.

  9. Further results on stabilization for interval time-delay systems via new integral inequality approach.

    Science.gov (United States)

    Li, Zhichen; Bai, Yan; Huang, Congzhi; Yan, Huaicheng

    2017-05-01

    This paper investigates the stability and stabilization problems for interval time-delay systems. By introducing a new delay partitioning approach, various Lyapunov-Krasovskii functionals with triple-integral terms are established to make full use of system information. In order to reduce the conservatism, improved integral inequalities are developed for estimation of double integrals, which show remarkable outperformance over the Jensen and Wirtinger ones. Particularly, the relationship between the time-delay and each subinterval is taken into consideration. The resulting stability criteria are less conservative than some recent methods. Based on the derived condition, the state-feedback controller design approach is also given. Finally, the numerical examples and the application to inverted pendulum system are provided to illustrate the effectiveness of the proposed approaches. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  10. Non-fusion surgery for degenerative spondylolisthesis using artificial ligament stabilization: surgical indication and clinical results.

    Science.gov (United States)

    Kanayama, Masahiro; Hashimoto, Tomoyuki; Shigenobu, Keiichi; Oha, Fumihiro; Ishida, Takashi; Yamane, Shigeru

    2005-03-01

    A retrospective study. To report midterm clinical and radiographic results of Graf artificial ligament stabilization in the treatment of degenerative spondylolisthesis and to evaluate the role of this procedure and its surgical indications for surgical success. Nonfusion surgeries including artificial disc replacement and ligamentoplasty are increasingly gaining interest to avoid adverse effects of spinal fusion. Sixty-four consecutive patients with degenerative spondylolisthesis underwent artificial ligament stabilization. Surgical indication was symptomatic degenerative spondylolisthesis with adjacent segment pathologies (6.3%). One patient (1.6%) underwent consequent spinal arthrodesis at the ligamentoplasty level. Artificial ligament stabilization did not improve the vertebral slip but maintained lordosis and preserved segmental motion in 80% of patients. This procedure is an effective alternative to spinal arthrodesis in the treatment of symptomatic degenerative spondylolisthesis (Grade I) with minimal disc space narrowing and coronal facet tropism.

  11. Hawaiian Electric Advanced Inverter Test Plan - Result Summary

    Energy Technology Data Exchange (ETDEWEB)

    Hoke, Anderson; Nelson, Austin; Prabakar, Kumaraguru; Nagarajan, Adarsh

    2016-10-14

    This presentation is intended to share the results of lab testing of five PV inverters with the Hawaiian Electric Companies and other stakeholders and interested parties. The tests included baseline testing of advanced inverter grid support functions, as well as distribution circuit-level tests to examine the impact of the PV inverters on simulated distribution feeders using power hardware-in-the-loop (PHIL) techniques. hardware-in-the-loop (PHIL) techniques.

  12. Stabilize ash using Clemson's sintering process (Part 1 - Phase 1 results): Mixed waste fly ash stabilization. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    Incineration of applicable Department of Energy (DOE) mixed wastes has produced a secondary waste stream of radioactive and Resource Conservation and Recovery Act (RCRA) hazardous fly ash that also requires treatment before land disposal. Unlike bottom ash, fly ash usually contains constituents making efficient stabilization difficult. For example, fly ash from the DOE Waste Experimental Reduction Facility (WERF) incinerator at the Idaho National Engineering and Environmental Laboratory (INEEL) contains volatile metals, metal salts, high concentrations of zinc, and unburned organic residues. All of these constituents can effect the stabilization process. The Department of Energy, and in particular the Mixed Waste Focus Area (MWFA) of EM-50, has stated the need for improved stabilization methods would accept a higher ash waste loading while meeting waste form disposal criteria. These alternative stabilization technologies should include delivery systems to minimize worker exposure and minimize secondary waste generation, while maximizing operational flexibility and radionuclide containment. Currently, the standard practice for stabilizing ash is mixing with Portland cement at room temperature. This standard practice produces a significant increase of waste material volume or has difficulty in adequately stabilizing the components in the fly ash to ensure regulatory requirements are consistently satisfied. To address these fly ash stabilization shortcomings, the MWFA, a DOE/EM-50 program, invested in the development of several fly ash stabilization alternatives, including the Clemson University sintering method

  13. Testing the effect of a microbial-based soil amendment on aggregate stability and erodibility

    DEFF Research Database (Denmark)

    Malozo, Mponda; Iversen, Bo Vangsø; Heckrath, Goswin Johann

    Minimizing soil erosion is essential for maintaining proper soil quality and thus preserving soil productivity. The erodibility of a soil is closely linked to its structural stability as well as its infiltrability. This study focuses on testing the effect of two different soil amendments on soil...... aggregate stability and erodibility. Two commercial products, gypsum and a microbial-based solution were used for the experiment and were tested on two Danish sandy loamy soils as well on a sandy soil from Tanzania. The carrier of the microbial-based product, a glycerol solution, was tested as well....... In the laboratory, soils were treated with the soil amendments in a two-step procedure at controlled water contents following aerobic incubation in closed containers. Water-aggregate stability and clay dispersion were measured on soil aggregates less than 8 mm in diameter. Aggregate stability was measured...

  14. Closed Kinetic Chain Upper Extremity Stability test (CKCUES test): a reliability study in persons with and without shoulder impingement syndrome.

    Science.gov (United States)

    Tucci, Helga Tatiana; Martins, Jaqueline; Sposito, Guilherme de Carvalho; Camarini, Paula Maria Ferreira; de Oliveira, Anamaria Siriani

    2014-01-03

    The Close Kinetic Chain Upper Extremity Stability Test (CKCUES test) is a low cost shoulder functional test that could be considered as a complementary and objective clinical outcome for shoulder performance evaluation. However, its reliability was tested only in recreational athletes' males and there are no studies comparing scores between sedentary and active samples. The purpose was to examine inter and intrasession reliability of CKCUES Test for samples of sedentary male and female with (SIS), for samples of sedentary healthy male and female, and for male and female samples of healthy upper extremity sport specific recreational athletes. Other purpose was to compare scores within sedentary and within recreational athletes samples of same gender. A sample of 108 subjects with and without SIS was recruited. Subjects were tested twice, seven days apart. Each subject performed four test repetitions, with 45 seconds of rest between them. The last three repetitions were averaged and used to statistical analysis. Intraclass Correlation Coefficient ICC2,1 was used to assess intrasession reliability of number of touches score and ICC2,3 was used to assess intersession reliability of number of touches, normalized score, and power score. Test scores within groups of same gender also were compared. Measurement error was determined by calculating the Standard Error of the Measurement (SEM) and Minimum detectable change (MDC) for all scores. The CKCUES Test showed excellent intersession reliability for scores in all samples. Results also showed excellent intrasession reliability of number of touches for all samples. Scores were greater in active compared to sedentary, with exception of power score. All scores were greater in active compared to sedentary and SIS males and females. SEM ranged from 1.45 to 2.76 touches (based on a 95% CI) and MDC ranged from 2.05 to 3.91(based on a 95% CI) in subjects with and without SIS. At least three touches are needed to be considered a

  15. Stability Test For Sorghum Mutant Lines Derived From Induced Mutations with Gamma-Ray Irradiation

    Directory of Open Access Journals (Sweden)

    S. Human

    2011-12-01

    Full Text Available Sorghum breeding program had been conducted at the Center for the Application of Isotopes and Radiation Technology, BATAN. Plant genetic variability was increased through induced mutations using gamma-ray irradiation. Through selection process in successive generations, some promising mutant lines had been identified to have good agronomic characteristics with high grain yield. These breeding lines were tested in multi location trials and information of the genotypic stability was obtained to meet the requirements for officially varietal release by the Ministry of Agriculture. A total of 11 sorghum lines and varieties consisting of 8 mutant lines derived from induced mutations (B-100, B-95, B-92, B-83, B-76, B-75, B-69 and Zh-30 and 3 control varieties (Durra, UPCA-S1 and Mandau were included in the experiment. All materials were grown in 10 agro-ecologically different locations namely Gunungkidul, Bantul, Citayam, Garut, Lampung, Bogor, Anyer, Karawaci, Cianjur and Subang. In each location, the local adaptability test was conducted by randomized block design with 3 replications. Data of grain yield was used for evaluating genotypic stability using AMMI approach. Results revealed that sorghum mutation breeding had generated 3 mutant lines (B-100, B-76 and Zh-30 exhibiting grain yield significantly higher than the control varieties. These mutant lines were genetically stable in all locations so that they would be recommended for official release as new sorghum varieties to the Ministry of Agriculture

  16. Ultrasonic, Molecular and Mechanical Testing Diagnostics in Natural Fibre Reinforced, Polymer-Stabilized Earth Blocks

    Directory of Open Access Journals (Sweden)

    C. Galán-Marín

    2013-01-01

    Full Text Available The aim of this research study was to evaluate the influence of utilising natural polymers as a form of soil stabilization, in order to assess their potential for use in building applications. Mixtures were stabilized with a natural polymer (alginate and reinforced with wool fibres in order to improve the overall compressive and flexural strength of a series of composite materials. Ultrasonic pulse velocity (UPV and mechanical strength testing techniques were then used to measure the porous properties of the manufactured natural polymer-soil composites, which were formed into earth blocks. Mechanical tests were carried out for three different clays which showed that the polymer increased the mechanical resistance of the samples to varying degrees, depending on the plasticity index of each soil. Variation in soil grain size distributions and Atterberg limits were assessed and chemical compositions were studied and compared. X-ray diffraction (XRD, X-ray fluorescence spectroscopy (XRF, and energy dispersive X-ray fluorescence (EDXRF techniques were all used in conjunction with qualitative identification of the aggregates. Ultrasonic wave propagation was found to be a useful technique for assisting in the determination of soil shrinkage characteristics and fibre-soil adherence capacity and UPV results correlated well with the measured mechanical properties.

  17. Selected Flight Test Results for Online Learning Neural Network-Based Flight Control System

    Science.gov (United States)

    Williams-Hayes, Peggy S.

    2004-01-01

    The NASA F-15 Intelligent Flight Control System project team developed a series of flight control concepts designed to demonstrate neural network-based adaptive controller benefits, with the objective to develop and flight-test control systems using neural network technology to optimize aircraft performance under nominal conditions and stabilize the aircraft under failure conditions. This report presents flight-test results for an adaptive controller using stability and control derivative values from an online learning neural network. A dynamic cell structure neural network is used in conjunction with a real-time parameter identification algorithm to estimate aerodynamic stability and control derivative increments to baseline aerodynamic derivatives in flight. This open-loop flight test set was performed in preparation for a future phase in which the learning neural network and parameter identification algorithm output would provide the flight controller with aerodynamic stability and control derivative updates in near real time. Two flight maneuvers are analyzed - pitch frequency sweep and automated flight-test maneuver designed to optimally excite the parameter identification algorithm in all axes. Frequency responses generated from flight data are compared to those obtained from nonlinear simulation runs. Flight data examination shows that addition of flight-identified aerodynamic derivative increments into the simulation improved aircraft pitch handling qualities.

  18. DYNAMIC STABILITY OF THE SOLAR SYSTEM: STATISTICALLY INCONCLUSIVE RESULTS FROM ENSEMBLE INTEGRATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Zeebe, Richard E., E-mail: zeebe@soest.hawaii.edu [School of Ocean and Earth Science and Technology, University of Hawaii at Manoa, 1000 Pope Road, MSB 629, Honolulu, HI 96822 (United States)

    2015-01-01

    Due to the chaotic nature of the solar system, the question of its long-term stability can only be answered in a statistical sense, for instance, based on numerical ensemble integrations of nearby orbits. Destabilization of the inner planets, leading to close encounters and/or collisions can be initiated through a large increase in Mercury's eccentricity, with a currently assumed likelihood of ∼1%. However, little is known at present about the robustness of this number. Here I report ensemble integrations of the full equations of motion of the eight planets and Pluto over 5 Gyr, including contributions from general relativity. The results show that different numerical algorithms lead to statistically different results for the evolution of Mercury's eccentricity (e{sub M}). For instance, starting at present initial conditions (e{sub M}≃0.21), Mercury's maximum eccentricity achieved over 5 Gyr is, on average, significantly higher in symplectic ensemble integrations using heliocentric rather than Jacobi coordinates and stricter error control. In contrast, starting at a possible future configuration (e{sub M}≃0.53), Mercury's maximum eccentricity achieved over the subsequent 500 Myr is, on average, significantly lower using heliocentric rather than Jacobi coordinates. For example, the probability for e{sub M} to increase beyond 0.53 over 500 Myr is >90% (Jacobi) versus only 40%-55% (heliocentric). This poses a dilemma because the physical evolution of the real system—and its probabilistic behavior—cannot depend on the coordinate system or the numerical algorithm chosen to describe it. Some tests of the numerical algorithms suggest that symplectic integrators using heliocentric coordinates underestimate the odds for destabilization of Mercury's orbit at high initial e{sub M}.

  19. Understanding why negative genetic test results sometimes fail to reassure.

    Science.gov (United States)

    Michie, Susan; Smith, Jonathan A; Senior, Victoria; Marteau, Theresa M

    2003-06-15

    A proportion of those receiving negative results following predictive genetic testing desire future bowel screening. This is despite a negative result meaning a general population risk of 1:7500 and despite bowel screening being experienced as aversive and clinically unnecessary. This study aimed to investigate perceptions of risk, illness, and tests amongst those receiving negative results following predictive genetic testing. Interviews with nine people receiving negative genetic test results for familial adenomatous polyposis (FAP) were analyzed using the qualitative method, interpretative phenomenological analysis (IPA). Those not reassured by negative genetic test results perceived a continuing risk to themselves and to their children. Two sets of perceptions emerged that might explain this: (1). perceptions of the genetic basis of the condition (FAP). Although the condition was perceived to be genetic, genetic status was seen as transient, so a result today could not predict the future. The condition was also seen as caused by factors other than genes, so information about only one risk factor could not be reassuring. (2). Perceptions of the genetic test. There was a lack of conviction in the ability of the genetic test, based on a blood sample, to predict a disease located in the bowel. These results suggest that some individuals receiving negative test results are not reassured because of their representations of the cause of their condition and the nature of the tests they undergo. It may be that eliciting and, when appropriate, changing people's representations prior to testing may enable those receiving negative results to be more reassured about their residual risk. Copyright 2003 Wiley-Liss, Inc.

  20. Test results judgment method based on BIT faults

    Directory of Open Access Journals (Sweden)

    Wang Gang

    2015-12-01

    Full Text Available Built-in-test (BIT is responsible for equipment fault detection, so the test data correctness directly influences diagnosis results. Equipment suffers all kinds of environment stresses, such as temperature, vibration, and electromagnetic stress. As embedded testing facility, BIT also suffers from these stresses and the interferences/faults are caused, so that the test course is influenced, resulting in incredible results. Therefore it is necessary to monitor test data and judge test failures. Stress monitor and BIT self-diagnosis would redound to BIT reliability, but the existing anti-jamming researches are mainly safeguard design and signal process. This paper focuses on test results monitor and BIT equipment (BITE failure judge, and a series of improved approaches is proposed. Firstly the stress influences on components are illustrated and the effects on the diagnosis results are summarized. Secondly a composite BIT program is proposed with information integration, and a stress monitor program is given. Thirdly, based on the detailed analysis of system faults and forms of BIT results, the test sequence control method is proposed. It assists BITE failure judge and reduces error probability. Finally the validation cases prove that these approaches enhance credibility.

  1. The long-term stability of cement - Leaching tests

    International Nuclear Information System (INIS)

    Engkvist, I.; Albinsson, Y.; Johansson Engkvist, W.

    1996-06-01

    The concrete construction in the Swedish repository for long-lived low and intermediate level waste will give a stable chemical near field environment for 10 5 years. The pH is expected to exceed 12 for the life time for most of the radionuclides in the repository in both saline and non-saline groundwaters. This is shown by static leaching experiments performed in saline and non-saline granitic groundwater conditions. Five gram portions of crushed ordinary Portland cement paste were equilibrated with 20 ml of synthetic saline or non-saline groundwater in a nitrogen atmosphere. Each week 12 ml (60%) of the water was replaced. The withdrawn water was used for chemical analyses and the results were used to monitor the degradation of the cement paste. After eighty weeks, some samples were analysed for mineral composition and compared with the original unleached paste. The results indicated no secondary ettringite or calcite formation. The results also supported the conclusion that the salinity of the contacting water is of minor importance for the long-term performance of the cement paste. 18 refs, 32 figs

  2. The Dimensions Affecting Investment Resulting Stabilized Economic Growth in Bangladesh: Perception Analysis of Investors and Bankers

    Directory of Open Access Journals (Sweden)

    Islam Mohammad Saiful

    2017-04-01

    Full Text Available The purpose of the study is to identify the impact of some assumed dimensions as vital reasons for investment sluggishness in Bangladesh resulting stabilized GDP growth rate around 6 percent over last decade in spite of having some favorable microeconomic and macroeconomic indicators such as controlled inflation rate, huge foreign exchange reserve, export growth etc. The study is descriptive in nature where correlation, regression and trend analysis have been conducted from the data of primary and secondary sources. The result of the analysis shows that mainly five important dimensions of investment sluggishness named high lending interest rate, corruption in public and private organizations, political unrest, inadequate power generation and supply and infrastructure problem are significantly affecting investment sluggishness in Bangladesh resulting stabilized GDP growth rate. At the end of the research paper, some measures have been recommended to overcome the obstacles of investment growth.

  3. Finite Element Analysis and Test Results Comparison for the Hybrid Wing Body Center Section Test Article

    Science.gov (United States)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.

    2016-01-01

    This report documents the comparison of test measurements and predictive finite element analysis results for a hybrid wing body center section test article. The testing and analysis efforts were part of the Airframe Technology subproject within the NASA Environmentally Responsible Aviation project. Test results include full field displacement measurements obtained from digital image correlation systems and discrete strain measurements obtained using both unidirectional and rosette resistive gauges. Most significant results are presented for the critical five load cases exercised during the test. Final test to failure after inflicting severe damage to the test article is also documented. Overall, good comparison between predicted and actual behavior of the test article is found.

  4. Results of recent KROTOS FCI tests. Alumina vs. corium melts

    Energy Technology Data Exchange (ETDEWEB)

    Huhtiniemi, I.; Magallon, D.; Hohmann, H. [Commission of the European Communities, Ispra (Italy). Joint Research Center

    1998-01-01

    Recent results from KROTOS fuel-coolant interaction experiments are discussed. Five tests with alumina were performed under highly subcooled conditions, all of these tests resulted in spontaneous steam explosions. Additionally, four tests were performed at low subcooling to confirm, on one hand, the suppression of spontaneous steam explosions under such conditions and, on the other hand, that such a system is still triggerable using an external initiator. The other test parameters in these alumina tests included the melt superheat and the initial pressure. All the tests in the investigated superheat range (150 K - 750 K) produced a steam explosion and no evidence of the explosion suppression by the elevated initial pressure (in the limited range of 0.1 - 0.375 MPa) was observed in the alumina tests. The corium test series include a test with 3 kg of melt under both subcooled and near saturated conditions at ambient pressure. Two additional tests were performed with subcooled water; one test was performed at an elevated pressure of 0.2 MPa with 2.4 kg of melt and another test with 5.1 kg of melt at ambient pressure. None of these tests with corium produced a propagating energetic steam explosion. However, propagating low energy (about twice the energy of the trigger pulse) events were observed. All corium tests produced significantly higher water level swells during the mixing phase than the corresponding alumina tests. Present experimental evidence suggests that the water depletion in the mixing zone suppresses energetic steam explosions with corium melts at ambient pressure and in the present pour geometry. Processes that could produce such a difference in void generation are discussed. (author)

  5. Stability testing of extemporaneous preparation of methyl salicylate ointment

    Directory of Open Access Journals (Sweden)

    H A Makeen

    2018-01-01

    Results: The shelf life (t90% of extemporaneously prepared methyl salicylate ointment was found to be 131 days at room temperature (25°C ± 5°C and 176 days in the refrigerator (2°C–8°C. Conclusion: The methyl salicylate present in extemporaneous ointment preparation is fairly stable at cool temperatures but shows faster degradation at higher temperature conditions. Therefore, it is recommended that an expiry date of 4 months can be safely mentioned when stored in cool.

  6. Physical and chemical test results of electrostatic safe flooring materials

    Science.gov (United States)

    Gompf, R. H.

    1988-01-01

    This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.

  7. PEP Support Laboratory Leaching and Permeate Stability Tests

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Renee L.; Peterson, Reid A.; Rinehart, Donald E.; Buchmiller, William C.

    2009-09-25

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Hanford Tank Waste Treatment and Immobilization Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed, and operated as part of a plan to respond to issue M12, "Undemonstrated Leaching Processes," of the External Flowsheet Review Team (EFRT) issue response plan.( ) The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. A simplified flow diagram of the PEP system is shown in Figure 1.1. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP and vessels UFP-VSL-00001A and B in the WTP PTF). In both scenarios, 19-M sodium hydroxide solution (NaOH, caustic) is added to the waste slurry in the vessels to leach solid aluminum compounds (e.g., gibbsite, boehmite). Caustic addition is followed by a heating step that uses direct injection of steam to accelerate the leach process. Following the caustic leach, the vessel contents are cooled using vessel cooling jackets and/or external heat exchangers. The main difference between the two scenarios is that for leaching in UFP-VSL-T01A and B, the 19-M NaOH is added to un-concentrated waste slurry (3 to 8 wt% solids), while for leaching in

  8. Commissioning and First Results from the Fermilab Cryomodule Test Stand

    Energy Technology Data Exchange (ETDEWEB)

    Harms, Elvin; et al.

    2017-05-01

    A new test stand dedicated to SRF cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cooled down and powered in this facility is the prototype 1.3 GHz cryomodule assembled at Fermilab for LCLS-II. We describe the demonstrated capabilities of CMTS1, report on steps taken during commissioning, provide an overview of first test results, and survey future plans.

  9. Sims Prototype System 2 Test Results - Engineering Analysis

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-01-01

    This report describes the testing, the problems encountered, and the results and conclusions obtained from tests performed on the IBM Prototype system 2, solar hot water system, at the Marshall space flight Center Solar Test Facility. System 2 is a liquid, non-draining solar energy system for supplying domestic hot water to singe residences. The system consists of collectors, storage tank, heat exchanger, pumps and associated plumbing and controls.

  10. Thermal Stability Test of Sugar Alcohols as Phase Change Materials for Medium Temperature Energy Storage Application

    OpenAIRE

    Solé, Aran; Neumann, Hannah; Niedermaier, Sophia; Cabeza, Luisa F.; Palomo, Elena

    2014-01-01

    Sugar alcohols are potential phase change materials candidates as they present high phase change enthalpy values, are non-toxic and low cost products. Three promising sugar-alcohols were selected: D-mannitol, myo-inositol and dulcitol under high melting enthalpy and temperature criterion. Thermal cycling tests were performed to study its cycling stability which can be determining when selecting the suitable phase change material. D-mannitol and dulcitol present poor thermal stability...

  11. Data Fusion Modeling for an RT3102 and Dewetron System Application in Hybrid Vehicle Stability Testing

    OpenAIRE

    Zhibin Miao; Hongtian Zhang

    2015-01-01

    More and more hybrid electric vehicles are driven since they offer such advantages as energy savings and better active safety performance. Hybrid vehicles have two or more power driving systems and frequently switch working condition, so controlling stability is very important. In this work, a two-stage Kalman algorithm method is used to fuse data in hybrid vehicle stability testing. First, the RT3102 navigation system and Dewetron system are introduced. Second, a modeling of data fusion is p...

  12. RTG performance on Galileo and Ulysses and Cassini test results

    International Nuclear Information System (INIS)

    Kelly, C. Edward; Klee, Paul M.

    1997-01-01

    Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Similar comparisons are made for the RTG on the Ulysses spacecraft which completed its planned mission in 1995. Also presented are test results from small scale thermoelectric modules and full scale converters performed for the Cassini program. The Cassini mission to Saturn is scheduled for an October 1997 launch. Small scale module test results on thermoelectric couples from the qualification and flight production runs are shown. These tests have exceeded 19,000 hours are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. Test results are presented for full scale units both ETGs (E-6, E-7) and RTGs (F-2, F-5) along with mission power predictions. F-5, fueled in 1985, served as a spare for the Galileo and Ulysses missions and plays the same role in the Cassini program. It has successfully completed all acceptance testing. The ten years storage between thermal vacuum tests is the longest ever experienced by an RTG. The data from this test are unique in providing the effects of long term low temperature storage on power output. All ETG and RTG test results to date indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of at least five percent are predicted

  13. RTG performance on Galileo and Ulysses and Cassini test results

    International Nuclear Information System (INIS)

    Kelly, C.E.; Klee, P.M.

    1997-01-01

    Power output from telemetry for the two Galileo RTGs are shown from the 1989 launch to the recent Jupiter encounter. Comparisons of predicted, measured and required performance are shown. Similar comparisons are made for the RTG on the Ulysses spacecraft which completed its planned mission in 1995. Also presented are test results from small scale thermoelectric modules and full scale converters performed for the Cassini program. The Cassini mission to Saturn is scheduled for an October 1997 launch. Small scale module test results on thermoelectric couples from the qualification and flight production runs are shown. These tests have exceeded 19,000 hours are continuing to provide increased confidence in the predicted long term performance of the Cassini RTGs. Test results are presented for full scale units both ETGs (E-6, E-7) and RTGs (F-2, F-5) along with mission power predictions. F-5, fueled in 1985, served as a spare for the Galileo and Ulysses missions and plays the same role in the Cassini program. It has successfully completed all acceptance testing. The ten years storage between thermal vacuum tests is the longest ever experienced by an RTG. The data from this test are unique in providing the effects of long term low temperature storage on power output. All ETG and RTG test results to date indicate that the power requirements of the Cassini spacecraft will be met. BOM and EOM power margins of at least five percent are predicted. copyright 1997 American Institute of Physics

  14. Drug and alcohol testing results 2002 annual report

    Science.gov (United States)

    2005-02-01

    This the 7th annual report of the results of the FTA Drug and Alcohol Testing Program. The report summarizes the new reporting requirements introduced for calendar year 2001, the requirements of the overall drug and alcohol testing program, the resul...

  15. Usefulness of Routine Antibacterial Susceptibility Testing Results for ...

    African Journals Online (AJOL)

    The objective was to evaluate the usefulness and reliability of routine antibacterial susceptibility testing data in antibacterial resistance surveillance in Lagos Metropolis. The antibacterial susceptibility testing results of 3,961 clinical isolates of bacteria from four highly rated hospitals in Lagos metropolis were collated and ...

  16. 42 CFR 493.1281 - Standard: Comparison of test results.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Comparison of test results. 493.1281 Section 493.1281 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived Testing Analytic Systems § 493.1281 Standard:...

  17. Laboratory Test Results for the Travelling Wave Fault Location Scheme

    Directory of Open Access Journals (Sweden)

    Krzysztof Glik

    2014-03-01

    Full Text Available The article describes the travelling wave fault location algorithm for high voltage lines based on wavelet transform. The algorithm is implemented in a prototype and tested in the laboratory. The article presents the hardware and software part of a travelling wave fault locator, methodology and test results.

  18. Results of EMC market surveillance tests for UPS systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamaeki, J. [Safety Technology Authority, Helsinki (Finland)

    1997-12-31

    This paper reports the first wide electromagnetic compatibility (EMC) market surveillance project in Finland in which the uninterruptible power systems (UPS) on the Finnish market are monitored. Altogether 11 UPS units are EMC tested and the results of these tests are described in this paper. The effect of basic characters of UPS on the level of electromagnetic interference are analysed. (orig.) 3 refs.

  19. Drug and alcohol testing results 2009 annual report

    Science.gov (United States)

    2013-11-01

    This is the 15th annual report of the results of the Federal Transit Administrations (FTA) Drug and Alcohol Testing Program. This report summarizes the reporting requirements for calendar year 2009, the requirements of the overall drug and alcohol...

  20. Drug and alcohol testing results 2007 annual report

    Science.gov (United States)

    2009-05-01

    This is the 13th annual report of the results of the Federal Transit Administrations (FTA) Drug and Alcohol Testing Program. This report summarizes the reporting requirements for calendar year 2007, the requirements of the overall drug and alcohol...

  1. Drug and Alcohol Testing Results 2008 Annual Report

    Science.gov (United States)

    2010-09-01

    This is the 14th annual report of the results of the Federal Transit Administration's (FTA) Drug and Alcohol Testing : Program. This report summarizes the reporting requirements for calendar year 2008, the requirements of the overall : drug and alcoh...

  2. Drug and alcohol testing results 2006 annual report.

    Science.gov (United States)

    2008-08-01

    This is the 12th annual report of the results of the Federal Transit Administration's (FTA) Drug and Alcohol Testing Program. This report summarizes the reporting requirements for calendar year 2006, the requirements of the overall drug and alcohol t...

  3. Drug and alcohol testing results 2001 annual report

    Science.gov (United States)

    2003-12-01

    This is the sixth annual report of the results of the Federal Transit Administration's (FTA) Drug and Alcohol Testing Program. The report summarizes the new reporting requirements introduced for calendar year 2001, the requirements of the overall dru...

  4. Long-term Stabilization of Disturbed Slopes Resulting from Construction Operations

    Science.gov (United States)

    2018-01-01

    Highway construction disturbs soil, which must be stabilized to prevent migration of soil particles into water bodies. Stabilization is enforced by law, regulation, and a permit system. Stabilization is most efficiently attained by reestablishment of...

  5. Interim results from UO2 fuel oxidation tests in air

    International Nuclear Information System (INIS)

    Campbell, T.K.; Gilbert, E.R.; Thornhill, C.K.; White, G.D.; Piepel, G.F.; Griffin, C.W.j.

    1987-08-01

    An experimental program is being conducted at Pacific Northwest Laboratory (PNL) to extend the characterization of spent fuel oxidation in air. To characterize oxidation behavior of irradiated UO 2 , fuel oxidation tests were performed on declad light-water reactor spent fuel and nonirradited UO 2 pellets in the temperature range of 135 to 250 0 C. These tests were designed to determine the important independent variables that might affect spent fuel oxidation behavior. The data from this program, when combined with the test results from other programs, will be used to develop recommended spent fuel dry-storage temperature limits in air. This report describes interim test results. The initial PNL investigations of nonirradiated and spent fuels identified the important testing variables as temperature, fuel burnup, radiolysis of the air, fuel microstructure, and moisture in the air. Based on these initial results, a more extensive statistically designed test matrix was developed to study the effects of temperature, burnup, and moisture on the oxidation behavior of spent fuel. Oxidation tests were initiated using both boiling-water reactor and pressurized-water reactor fuels from several different reactors with burnups from 8 to 34 GWd/MTU. A 10 5 R/h gamma field was applied to the test ovens to simulate dry storage cask conditions. Nonirradiated fuel was included as a control. This report describes experimental results from the initial tests on both the spent and nonirradiated fuels and results to date on the tests in a 10 5 R/h gamma field. 33 refs., 51 figs., 6 tabs

  6. Recent test results on the ATLAS SCT detector

    International Nuclear Information System (INIS)

    Pernegger, H.

    2003-01-01

    The ATLAS Semiconductor Tracker (SCT) will be a central part of the tracking system of the ATLAS experiment. The SCT, which is currently under construction, will consist of four concentric barrels of silicon detectors as well as two silicon endcap detectors formed by nine disks each. After an overview of the SCT and the detector module layout, the paper will summarize recent test results obtained from silicon detector modules, which have been extensively tested before starting their large series production. The tests presented here cover electrical performance of individual modules, their performance after irradiation, as well as system tests in a multi-module setup

  7. Preliminary results of steel containment vessel model test

    International Nuclear Information System (INIS)

    Matsumoto, T.; Komine, K.; Arai, S.

    1997-01-01

    A high pressure test of a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of a steel containment vessel (SCV), representing an improved boiling water reactor (BWR) Mark II containment, was conducted on December 11-12, 1996 at Sandia National Laboratories. This paper describes the preliminary results of the high pressure test. In addition, the preliminary post-test measurement data and the preliminary comparison of test data with pretest analysis predictions are also presented

  8. TF34 Quiet Nacelle nearfield acoustic test results

    Science.gov (United States)

    Coward, W. E.; Smith, E. B.; Sowers, H. D.

    1974-01-01

    The results of the nearfield acoustic tests conducted on the TF34 Quiet Nacelle are presented. The high fan noise suppression levels being sought (26 PNdB reduction in aft noise) necessitated the use of an extensive system of special nearfield acoustic instrumentation to properly evaluate the suppression achieved. The design, operation, and test results from each of these nearfield acoustic instrumentation systems are presented.

  9. Does core stability exercise improve lumbopelvic stability (through endurance tests) more than general exercise in chronic low back pain? A quasi-randomized controlled trial.

    Science.gov (United States)

    Shamsi, Mohammad Bagher; Rezaei, Mandana; Zamanlou, Mehdi; Sadeghi, Mehdi; Pourahmadi, Mohammad Reza

    2016-01-01

    The aim was to compare core stability and general exercises (GEs) in chronic low back pain (LBP) patients based on lumbopelvic stability (LPS) assessment through three endurance core stability tests. There is a controversy about preference of core stability exercise (CSE) over other types of exercise for chronic LBP. Studies which have compared these exercises used other outcomes than those related to LPS. As it is claimed that CSE enhances back stability, endurance tests for LPS were used. A 16-session CSE program and a GE program with the same duration were conducted for two groups of participants. Frequency of interventions for both groups was three times a week. Forty-three people (aged 18-60 years) with chronic non-specific LBP were alternately allocated to core stability (n = 22) or GE group (n = 21) when admitted. The primary outcomes were three endurance core stability tests including: (1) trunk flexor; (2) trunk extensor; and (3) side bridge tests. Secondary outcomes were disability and pain. Measurements were taken at baseline and the end of the intervention. After the intervention, test times increased and disability and pain decreased within groups. There was no significant difference between two groups in increasing test times (p = 0.23 to p = 0.36) or decreasing disability (p = 0.16) and pain (p = 0.73). CSE is not more effective than GE for improving endurance core stability tests and reducing disability and pain in chronic non-specific LBP patients.

  10. Influence of diet on the results of laboratory tests

    Directory of Open Access Journals (Sweden)

    Kinga Lis

    2013-12-01

    Full Text Available Blood and urine laboratory tests are necessary to diagnose the state of the patient. These tests are also helpful in the assessment of diet and nutritional status of the organism. It is recommended that both blood and urine for laboratory tests be collected in the morning, from fasting patients after an overnight rest. These conditions are defined as the standard conditions for collection of material for laboratory testing. Before testing, patients should follow their natural diet and avoid physical exertion, night work, long-distance travel, as well as consumption of alcohol and drugs. They should also reduce the consumption of synthetic vitamins and herbal remedies and other dietary supplements. Medications should be limited to those that are absolutely necessary. All of these factors can affect the results of laboratory tests.

  11. Hover test of a full-scale hingeless helicopter rotor: Aeroelastic stability, performance and loads data. [wind tunnel tests

    Science.gov (United States)

    Peterson, R. L.; Warmbrodt, W.

    1984-01-01

    A hover test of a full-scale, hingeless rotor system was conducted in the NASA Ames 40- by 80-foot wind tunnel. The rotor was tested on the Ames rotor test apparatus. Rotor aeroelastic stability, performance, and loads at various rotational speeds and thrust coefficients were investigated. The primary objective was to determine the inplane stability characteristics of the rotor system. Rotor inplane damping data were obtained for operation between 350 and 425 rpm (design speed), and for thurst coefficients between 0.0 and 0.12. The rotor was stable for all conditions tested. At constant rotor rotational speed, a minimum inplane dampling level was obtained at a thrust coefficient approximately = 0.02. At constant rotor lift, a minimum in rotor inplane damping was measured at 400 rpm.

  12. Laboratory tests of the response stability of the ATLAS Tile Calorimeter photomultipliers

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00216540; The ATLAS collaboration; Leone, Sandra; Scuri, Fabrizio

    2017-01-01

    High performance of the ATLAS Tile Calorimeter response is achieved with a multi- stage calibration. One step of the calibration is based on measurements of the response to laser pulse excitation of the PMTs used to read out the calorimeter cells. A facility to study the PMT stability response is operating in the PISA-INFN laboratories since 2015. Goals of the tests are to study the time evolution of the PMT response as a function of the integrated anode charge and to compare test bench results with the observed response drifts of the Tile Calorimeter PMTs during LHC Run I and Run II. A new statistical approach was used to measure the drift of the absolute PMT gain. A new procedure which combines studies of the time evolution of the global PMT responses and of the individual PMT gains was adopted to derive the evolution of the cathode quantum efficiency. The experimental setup of the Pisa facility is described and the first results obtained by testing about 30 PMTs Hamamatsu model R7877 (a special evolution f...

  13. Laboratory tests of the response stability of the ATLAS Tile Calorimeter photomultipliers

    CERN Document Server

    Kazanin, Vassili; The ATLAS collaboration; Scuri, Fabrizio

    2017-01-01

    High performance of the ATLAS Tile Calorimeter response is achieved with a multi-stage calibration. One step of the calibration is based on measurements of the response to laser pulse excitation of the PMTs used to read out the calorimeter cells. A facility to study the PMT stability response is operating in the PISA-INFN laboratories since 2015. Goals of the tests are to study the time evolution of the PMT response as a function of the integrated anode charge and to compare test bench results with the observed response drifts of the Tile Calorimeter PMTs during LHC Run I and Run II. A new statistical approach was used to measure the drift of the absolute PMT gain. A new procedure which combines studies of the time evolution of the global PMT responses and of the individual PMT gains was adopted to derive the evolution of the cathode quantum efficiency. The experimental setup of the Pisa facility is described and the first results obtained by testing about 30 PMTs Hamamatsu model R7877 (a special evolution fo...

  14. The Use of Dynamic Visual Acuity as a Functional Test of Gaze Stabilization Following Space Flight

    Science.gov (United States)

    Peters, B. T.; Mulavara, A. P.; Brady, R.; Miller, C. A.; Richards, J. T.; Warren, L. E.; Cohen, H. S.; Bloomberg, J. J.

    2006-01-01

    performance of some subjects nicely parallels the stereotypical recovery curve observed in the group mean data. Others show dramatic changes in DVA from one test day to another. These changes may be indicative of a re-adaptation process that is not characterized by a steady improvement with the passage of time, but is instead a dynamic search for appropriate coordinative strategy to achieve the desired gaze stabilization goal. Ground-based data have been collected in our lab using DVA with one of the goals being to improve the DVA test itself. In one of these studies, the DVA test was repeated using a visual target viewing distance of 0.5 meters. While walking, the relative contributions of the otoliths and semi-circular canals that are required to stabilize gaze are affected by visual target viewing distance. It may be possible to exploit this using the current treadmill DVA test to differentially assess changes in these vestibular subsystems. The postflight DVA evaluations currently used have been augmented to include the near target version of the test. Preliminary results from these assessments, as well as the results from the ground-based tests will also be reported. DVA provides a direct measure of a subject's ability to see clearly in the presence of self-motion. The use of the current tests for providing a functionally relevant metric is evident. However, it is possible to expand the scope of DVA testing to include scenarios other than walking. A facility for measuring DVA in the presence of passive movements is being created. Using a mechanized platform to provide the perturbation, it should be possible to simulate aircraft and automobile vibration profiles. Used in conjunction with the far and near visual displays this facility should be able to assess a subject s ability to clearly see distant objects as well as those that appear on the dashboard or instrument control panel during functionally relevant situations.

  15. Results of 2007 test beam of AMS-02 Electromagnetic Calorimeter

    Science.gov (United States)

    di Falco, Stefano

    2010-01-01

    The AMS-02 experiment will be delivered by the Space Shuttle Discovery to the ISS in summer 2010. The main goals of the experiment are search for antimatter and dark matter, high precision measurement of charged cosmic ray spectra and fluxes and study of gamma rays, in the GeV to TeV energy range. In AMS-02 the Electromagnetic Calorimeter (ECAL) is required to measure e+,e- and gamma energy and to discriminate electromagnetic showers from hadronic cascades. ECAL is based on a lead/scintillating fiber sandwich, providing a 3D imaging reconstruction of the showers. The electronics equipping the detector has low power consumption, low noise, large dynamic range readout and full double redundancy. The calorimeter successfully got through several space qualification tests concerning the mechanical and thermal stability, the electromagnetic compatibility and radiation hardness. The ECAL Flight Model was calibrated during Summer 2007 in a test beam at CERN, using 6-250 GeV electron and proton beams: angular and energy resolutions, obtained from these data, are reported.

  16. Blended-Wing-Body Low-Speed Flight Dynamics: Summary of Ground Tests and Sample Results

    Science.gov (United States)

    Vicroy, Dan D.

    2009-01-01

    A series of low-speed wind tunnel tests of a Blended-Wing-Body tri-jet configuration to evaluate the low-speed static and dynamic stability and control characteristics over the full envelope of angle of attack and sideslip are summarized. These data were collected for use in simulation studies of the edge-of-the-envelope and potential out-of-control flight characteristics. Some selected results with lessons learned are presented.

  17. Uprated OMS Engine Status-Sea Level Testing Results

    Science.gov (United States)

    Bertolino, J. D.; Boyd, W. C.

    1990-01-01

    The current Space Shuttle Orbital Maneuvering Engine (OME) is pressure fed, utilizing storable propellants. Performance uprating of this engine, through the use of a gas generator driven turbopump to increase operating pressure, is being pursued by the NASA Johnson Space Center (JSC). Component level design, fabrication, and test activities for this engine system have been on-going since 1984. More recently, a complete engine designated the Integrated Component Test Bed (ICTB), was tested at sea level conditions by Aerojet. A description of the test hardware and results of the sea level test program are presented. These results, which include the test condition operating envelope and projected performance at altitude conditions, confirm the capability of the selected Uprated OME (UOME) configuration to meet or exceed performance and operational requirements. Engine flexibility, demonstrated through testing at two different operational mixture ratios, along with a summary of projected Space Shuttle performance enhancements using the UOME, are discussed. Planned future activities, including ICTB tests at simulated altitude conditions, and recommendations for further engine development, are also discussed.

  18. Political Disaffection and Stability of Electoral Results in Chilean, 1993-2009

    Directory of Open Access Journals (Sweden)

    Octavio Avendaño

    2016-01-01

    Full Text Available This article analyses the electoral stability vis à vis the increase of unstable votes in 1993 and 2009 parliamentary elections in Chile. In contrast with other academic works which conceive little volatility as corollary of a persistent voter’s behavior, we argue that the electoral results are consequence of the electoral system which in fact generates change in electoral behavior. We have named this phenomenon as “self-compensation”. Data analyzed in this paper show an important decrease in stable voters and that mobility exists. Nevertheless, the special characteristic of the electoral mobility is what gives stability to voter’s behavior during this period. Palabras claves: Chile, sistema de partidos, elecciones, volatilidad, voto no estable. Keywords: Chile, party system, elections, volatility, vote not stable.

  19. Flight Test Results of a Thermoelectric Energy Harvester for Aircraft

    Science.gov (United States)

    Samson, D.; Kluge, M.; Fuss, T.; Schmid, U.; Becker, Th.

    2012-06-01

    The idea of thermoelectric energy harvesting for low-power wireless sensor systems in aircraft and its practical implementation was recently published. The concept of using a thermoelectric generator (TEG) attached to the aircraft inner hull and a thermal storage device to create an artificial temperature gradient at the TEG during take-off and landing from the temperature changes of the fuselage has passed initial tests and is now subject to flight testing. This work presents preflight test results, e.g., vibration and temperature testing of the harvesters, the practical installation of two harvesting devices inside a test plane, and the first test flight results. Several flight cycles with different flight profiles, flight lengths, and outside temperatures have been performed. Although the influence of different flight profiles on the energy output of the harvester can be clearly observed, the results are in good agreement with expectations from numerical simulations with boundary conditions evaluated from initial climate chamber experiments. In addition, the flight test demonstrates that reliable operation of thermoelectric energy harvesting in harsh aircraft environments seems to be feasible, therefore paving the way for realization of energy-autonomous, wireless sensor networks.

  20. ExEP yield modeling tool and validation test results

    Science.gov (United States)

    Morgan, Rhonda; Turmon, Michael; Delacroix, Christian; Savransky, Dmitry; Garrett, Daniel; Lowrance, Patrick; Liu, Xiang Cate; Nunez, Paul

    2017-09-01

    EXOSIMS is an open-source simulation tool for parametric modeling of the detection yield and characterization of exoplanets. EXOSIMS has been adopted by the Exoplanet Exploration Programs Standards Definition and Evaluation Team (ExSDET) as a common mechanism for comparison of exoplanet mission concept studies. To ensure trustworthiness of the tool, we developed a validation test plan that leverages the Python-language unit-test framework, utilizes integration tests for selected module interactions, and performs end-to-end crossvalidation with other yield tools. This paper presents the test methods and results, with the physics-based tests such as photometry and integration time calculation treated in detail and the functional tests treated summarily. The test case utilized a 4m unobscured telescope with an idealized coronagraph and an exoplanet population from the IPAC radial velocity (RV) exoplanet catalog. The known RV planets were set at quadrature to allow deterministic validation of the calculation of physical parameters, such as working angle, photon counts and integration time. The observing keepout region was tested by generating plots and movies of the targets and the keepout zone over a year. Although the keepout integration test required the interpretation of a user, the test revealed problems in the L2 halo orbit and the parameterization of keepout applied to some solar system bodies, which the development team was able to address. The validation testing of EXOSIMS was performed iteratively with the developers of EXOSIMS and resulted in a more robust, stable, and trustworthy tool that the exoplanet community can use to simulate exoplanet direct-detection missions from probe class, to WFIRST, up to large mission concepts such as HabEx and LUVOIR.

  1. Wind turbine wake interactions; results from blind tests

    Science.gov (United States)

    Krogstad, Per-Åge; Sætran, Lars

    2015-06-01

    Results from three "Blind test" Workshops on wind turbine wake modeling are presented. While the first "Blind test" (BT1, 2011) consisted of a single model turbine located in a large wind tunnel, the complexity was increased for each new test in order to see how various models performed. Thus the next "Blind test" (BT2, 2012) had two turbines mounted in-line. This is a crucial test for models intended to predict turbine performances in a wind farm. In the last "Blind test" (BT3, 2013) the two turbines were again mounted in-line, but offset sideways so that the rotor of the downstream turbine only intersected half the wake from the upstream turbine. This case produces high dynamic loads and strong asymmetry in the wake. For each "Blind test" the turbine geometry and wind tunnel environment was specified and the participants were asked to predict the turbine performances, as well as the wake development to five diameters downstream of the second turbine. For the first two tests axisymmetry could be assumed if the influence of the towers was neglected. This was not possible in BT3 and therefore only fully 3D methods could be applied. In all tests the prediction scatter was surprisingly high.

  2. Automated Testing Infrastructure and Result Comparison for Geodynamics Codes

    Science.gov (United States)

    Heien, E. M.; Kellogg, L. H.

    2013-12-01

    The geodynamics community uses a wide variety of codes on a wide variety of both software and hardware platforms to simulate geophysical phenomenon. These codes are generally variants of finite difference or finite element calculations involving Stokes flow or wave propagation. A significant problem is that codes of even low complexity will return different results depending on the platform due to slight differences in hardware, software, compiler, and libraries. Furthermore, changes to the codes during development may affect solutions in unexpected ways such that previously validated results are altered. The Computational Infrastructure for Geodynamics (CIG) is funded by the NSF to enhance the capabilities of the geodynamics community through software development. CIG has recently done extensive work in setting up an automated testing and result validation system based on the BaTLab system developed at the University of Wisconsin, Madison. This system uses 16 variants of Linux and Mac platforms on both 32 and 64-bit processors to test several CIG codes, and has also recently been extended to support testing on the XSEDE TACC (Texas Advanced Computing Center) Stampede cluster. In this work we overview the system design and demonstrate how automated testing and validation occurs and results are reported. We also examine several results from the system from different codes and discuss how changes in compilers and libraries affect the results. Finally we detail some result comparison tools for different types of output (scalar fields, velocity fields, seismogram data), and discuss within what margins different results can be considered equivalent.

  3. Stability of selected volatile contact allergens in different patch test chambers under different storage conditions

    DEFF Research Database (Denmark)

    Mose, Kristian Fredløv; Andersen, Klaus Ejner; Christensen, Lars Porskjaer

    2012-01-01

    storage conditions. Methods. Petrolatum samples of methyl methacrylate (MMA), 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxypropyl acrylate (2-HPA), cinnamal and eugenol in patch test concentrations were stored in three different test chambers (IQ chamber™, IQ Ultimate™, and Van der Bend® transport...... during storage in the refrigerator. For these two chamber systems, the contact allergen concentration dropped below the stability limit in the following order: MMA, cinnamal, 2-HPA, eugenol, and 2-HEMA. In the Van der Bend® transport container, the contact allergens exhibited acceptable stability under...

  4. [Results of spontaneous NBT-test in influenza patients].

    Science.gov (United States)

    Nagoev, B S; Orazaev, N G

    2000-01-01

    Assessment of leukocyte activity with spontaneous NBT-test in influenza patients regarding the disease stage, severity, complication and concomitant diseases. 107 influenza patients aged 16-84 years were studied. 70 patients had no complications, 11 patients had early influenzal pneumonia, 26 patients had late viral-bacterial infection. Chronic concomitant diseases were diagnosed in 23 cases. Cytochemical examination of leukocyte activity was made in all the patients using spontaneous NBT-test. In mild influenza NBT-test results were within upper limits of normal value. In alleviation of the symptoms NBT-test parameters were low. In early influenzal and viral-bacterial pneumonia leukocyte activity was high and lowered to normal in late convalescence. Parameters of spontaneous NBT-test in influenzal patients were elevated depending on influenza stage, severity and complications. This fact is of differential-diagnostic importance.

  5. Thermal stability test of UO{sub 2}-doped pellet manufactured at INB

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Diogo R., E-mail: diogoribeiro@inb.gov.br [Indústrias Nucleares do Brasil S.A. (FCN/INB), Resende, RJ (Brazil). Fábrica de Combustível Nuclear; Freitas, Artur C., E-mail: artur.freitas@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The thermal stability test of UO{sub 2}-doped pellet manufactured at INB was carried out in order to analyze the resintering behavior. This analysis is fundamental for predicting dimensional behavior during irradiation. INB commonly performs resintering test to qualify its production lots, and the same methodology was applied to UO{sub 2}-doped pellets. In this preliminary study, three sets of experiments have been made: 1) without any chemical additive (Z test, the standard UO{sub 2} pellets - undoped); 2) UO{sub 2} pellets doped with 0.1, 0.2 and 0.3 wt% of Al{sub 2}O{sub 3}; and 3) 0.1, 0.2 and 0.3 wt% of Nb{sub 2}O{sub 5}. The preliminary results showed an increase in sintered density in all resintering experiments. So as to obtain the percentage increase, the theoretical densities (g/cm{sup 3} and %TD) were calculated based on the undoped UO{sub 2} pellets. All samples increased in a range of 0.27 to 0.32 %TD the out-pile densification during the resintering process. However, the Z(Nb)3 test showed the lowest value of 0.08 %TD, which is not in agreement with the INB specification limits. The sintered density of this test (0.3 wt% niobia) was 96.15% TD. This fact might be related to the competitive mechanism between Kirkendall effect, forming porosity owing to niobium solubilization on UO{sub 2} matrix, and densification process as a result of uranium diffusivity. Thus, the densification was only 0.08 %TD in Z(Nb)3 sample. All the other samples were in agreement with INB specification. (author)

  6. Steel Containment Vessel Model Test: Results and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Costello, J.F.; Hashimote, T.; Hessheimer, M.F.; Luk, V.K.

    1999-03-01

    A high pressure test of the steel containment vessel (SCV) model was conducted on December 11-12, 1996 at Sandia National Laboratories, Albuquerque, NM, USA. The test model is a mixed-scaled model (1:10 in geometry and 1:4 in shell thickness) of an improved Mark II boiling water reactor (BWR) containment. A concentric steel contact structure (CS), installed over the SCV model and separated at a nominally uniform distance from it, provided a simplified representation of a reactor shield building in the actual plant. The SCV model and contact structure were instrumented with strain gages and displacement transducers to record the deformation behavior of the SCV model during the high pressure test. This paper summarizes the conduct and the results of the high pressure test and discusses the posttest metallurgical evaluation results on specimens removed from the SCV model.

  7. Tensile and fracture toughness test results of neutron irradiated beryllium

    Energy Technology Data Exchange (ETDEWEB)

    Chaouadi, R.; Moons, F.; Puzzolante, J.L. [Centre d`Etude de l`Energie Nucleaire, Mol (Belgium)

    1998-01-01

    Tensile and fracture toughness test results of four Beryllium grades are reported here. The flow and fracture properties are investigated by using small size tensile and round compact tension specimens. Irradiation was performed at the BR2 material testing reactor which allows various temperature and irradiation conditions. The fast neutron fluence (>1 MeV) ranges between 0.65 and 2.45 10{sup 21} n/cm{sup 2}. In the meantime, un-irradiated specimens were aged at the irradiation temperatures to separate if any the effect of temperature from irradiation damage. Test results are analyzed and discussed, in particular in terms of the effects of material grade, test temperature, thermal ageing and neutron irradiation. (author)

  8. COMPARISON OF RESULTS OF THERMAL TESTS OF BALCONY DOORS

    Directory of Open Access Journals (Sweden)

    Golubev Stanislav Sergeevich

    2012-10-01

    Full Text Available Results of thermal tests of balcony doors are presented in the article. In the course of the research project, two types of doors were tested. The first type represents a PVC frame door (width 82 mm; it has a triple glazing (4K-16Ar-4-16Ar-K4; its blank part represents a polystyrene sandwich panel (width 40 mm. The second type represents a PVC frame door (width 82 mm, that has a triple glazing (4K-16Ar-4-16Ar-K4 and composite PVC panels. The testing procedure and processing results are described in the article. The test has demonstrated that the thermal resistance value of the balcony door of the first type exceeds the thermal resistance value of the balcony door of the second type.

  9. Test Beam Results of a 3D Diamond Detector

    CERN Document Server

    Dunser, Marc

    2015-01-01

    3D pixel technology has been used successfully in the past with silicon detectors for tracking applications. Recently, a first prototype of the same 3D technology has been produced on a chemical vapour deposited single-crystal diamond sensor. This device has been subsequently tested in a beam test at CERN’s SPS accelerator in a beam of 120 GeV protons. Details on the production and results of testbeam data are presented.

  10. First Test Results of the 4-ROD Crab Cavity

    CERN Document Server

    Ambattu, P; Burt, G; Calaga, R; Capatina, O; Calatroni, S; Ciapala, E; Doherty, D; Ferreira, L; Jensen, E; Hall, B; Lingwood, C; Maesen, P; Mongelluzzo, A; Renaglia, T; Therasse, M

    2013-01-01

    The first compact prototype crab cavity with the 4rod geometry has undergone surface treatment and cold testing. Due to the complex geometry and unique fabrication procedure, RF validation of the field at beyond the nominal operating voltage at a sufficiently high Q0 is an important pre-requisite. Preliminary results of the first cold tests are presented along with cavity performance at different stages of the cavity processing is described.

  11. Improved PFB operations - 400-hour turbine test results

    Science.gov (United States)

    Rollbuhler, R. J.; Benford, S. M.; Zellars, G. R.

    1980-04-01

    The paper deals with a 400-hr small turbine test in the effluent of a pressurized fluidized bed (PFB) at an average temperature of 770 C, an average relative gas velocity of 300 m/sec, and average solid loadings of 200 ppm. Consideration is given to combustion parameters and operating procedure as well as to the turbine system and turbine test operating procedures. Emphasis is placed on erosion/corrosion results.

  12. Results of initial nuclear tests on LWBR (LWBR Development Program)

    International Nuclear Information System (INIS)

    Sarber, W.K.

    1979-06-01

    This report presents and discusses the results of physics tests performed at beginning of life on the Light Water Breeder Reactor (LWBR). These tests have confirmed that movable seed assembly critical positions and reactivity worths, temperature coefficients, xenon transient characteristics, core symmetry, and core shutdown are within the range of values used in the design of the LWBR and its reactor protection analysis. Measured core physics parameters were found to be in good agreement with the calculated values

  13. Construction details and test results from RHIC sextupoles

    International Nuclear Information System (INIS)

    Lindner, M.; Anerella, M.; Ganetis, G.

    1993-01-01

    Four 8 cm aperture sextupoles have been built at BNL to verify the magnetic performance of this magnet in the RHIC installation. Two significantly different mechanical configurations have been designed, and two magnets of each design have been built, and successfully tested, and have exceeded the required minimum quench current by a substantial margin. This report describes the assembly details of the second configuration, which is the final production configuration. In addition the first industry built production sextupole has been delivered and tested. This report presents the results of quench tests on all 5 magnets and field measurements on the first production sextupole

  14. Changes of Soil Aggregate Stability as a Result of the Effect of Freeze-thaw Cycles

    Directory of Open Access Journals (Sweden)

    Aneta Žabenská

    2015-01-01

    Full Text Available The objective of the present research was to assess the changes in soil erodibility during the non-vegetation period as one of the factors affecting the snowmelt erosion. The temperature fluctuation was simulated with the use of a climatic chamber ex situ. The soil surface was for simplicity reasons considered without any plant or snow cover. The paper deals with the rate of soil erodibility determination – the soil erodibility should increase due to the decrease of soil aggregate stability depending on the number of freeze-thaw cycles and initial soil moisture. Soil samples (taken from three sites were subjected to freeze-thaw cycles under laboratory conditions. Changes in soil agreggate stability were monitored as one of the main soil characteristics which determine the soil erodibility. Two methods were used to determine the soil macroaggregate stability (soil aggregate fraction 1–2 mm: standard single-sieve method of wet sieving (Kemper and Rosenau, 1986, and dry aggregate analysis using a set of flat sieves with a diameter of 1 mm and 0.5 mm. The results of each method are controversial. Intended hypothesis has not been clearly confirmed.

  15. Physical separations soil washing system cold test results

    Energy Technology Data Exchange (ETDEWEB)

    McGuire, J.P.

    1993-07-28

    This test summary describes the objectives, methodology, and results of a physical separations soil-washing system setup and shakedown test using uncontaminated soil. The test is being conducted in preparation for a treatability test to be conducted in the North Pond of the 300-FF-1 Operable Unit. It will be used to assess the feasibility of using a physical separations process to reduce the volume of contaminated soils in the 300-FF-1 Operable Unit. The test is described in DOE-RL (1993). The setup test was conducted at an uncontrolled area located approximately 3.2 km northwest of the 300-FF-1 Operable Unit. The material processed was free of contamination. The physical separation equipment to be used in the test was transferred to the US Department of Energy (DOE) by the US Environmental Protection Agency (EPA) Risk Reduction Engineering Laboratory. On May 13, 1993, soil-washing equipment was moved to the cold test location. Design assistance and recommendation for operation was provided by the EPA.

  16. Development of Technique for Testing the Long-Term Stability of Silicon Microstrip Detectors

    International Nuclear Information System (INIS)

    Kosinov, A.V.; Maslov, N.I.; Naumov, S.V.; Ovchinnik, V.D.; Starodubtsev, A.F.; Vasiliev, G.P.; Yalovenko, V.I.; Bosisio, L.

    2006-01-01

    An automatic multi-channel set-up prototype for simultaneous testing of the Long-Term Stability (LTS) of more than ten detectors is described. The Inner Tracking System of the ALICE experiment will include about two thousand Double-sided Microstrip Detectors (DSMD). Efficient automatic measurement techniques are crucial for the LTS test, because the corresponding test procedure should be performed on each detector and requires long time, at least two days. By using special adapters for supporting and connecting the bare DSMDs, failing detectors can be screened out before module assembly, thus minimizing the cost. Automated probe stations developed for a special purpose or for microelectronics industry are used for measuring physical static DSMD characteristics and check good-to-bad elements ratio for DSMD. However, automated (or semi-automatic)test benches for studying LTS or testing DSMD long-term stability before developing a detecting module are absent

  17. Temperature Stability and Control Requirements for Thermal Vacuum/Thermal Balance Testing of the Aquarius Radiometer

    Science.gov (United States)

    Johnson, Chris

    2008-01-01

    The paper describes the specific temperature stability and control requirements for the thermal vacuum and thermal balance testing of the Aquarius Instrument at the Goddard Space Flight Center in Greenbelt, Maryland. The testing was conducted in the 10' wide x 15' deep Facility 225 Thermal Vacuum chamber. The temperature control stability requirements were less than .14 C RMS thermal variation over a seven-day period. The thermal test specification also called for the ability to impose a high-resolution sinusoidal variation for all heater zones. The special requirements of the Aquarius radiometer test necessitated the construction of a multi-function test fixture and the modification of two existing heater controller racks.

  18. Patch Test Results in Patients with Allergic Contact Dermatitis / Mucositis

    Directory of Open Access Journals (Sweden)

    Özlem Su

    2008-05-01

    Full Text Available Background and Design: The aims of our study were to determine the frequency of positive patch reactions and the most common allergens in patients with allergic contact dermatitis (ACD and/or mucositis(M who underwent with T.R.U.E. “Thin-layer Rapid-Use Epicutaneous” test and evaluate supplemantal series used with T.R.U.E. test effect on patch test results.Material and Method: In this study 161 ACD, 5 ACM, 1 ACD and ACM were enrolled. While 139 of all patients were patch tested with T.R.U.E. test alone,out of 28 patients were tested for T.R.U.E. test and also with supplemental series that included textile colours (9 of tested patients, plastic and glues (9, dental screening (6, backery (2, cosmetic (1 and plastic and glues and dental screening (1. Supplemental series were chosen according to patient’s occupation and clinic presentation. The data from our patients were analyzed as percentage. The relationship between contact sensitization and atopic status was evaluated with Yate’s correlation x2 test.Results: Eighty-six male, 81 female were taken into this study. The median age was 36.5.While 25.9% of 139 patients tested with T.R.U.E. test alone,46.4% of 28 patients applied supplemental series in addition to T.R.U.E. test showed positive reaction to one or more allergens. The most common allergens were nickel sulphate (14.4%, potassium dichromate (4.8%, fragrance mix (2.9% and colophony (2.9%. The most common supplemental allergens were octil gallat (50% in bakery and copper sulphate, goldsodiumthiosulphate (42.8% in dental screening. Positive patch reactions were detected 83.3% in 6 patients with AKM, 80% of these positive reactions was againts dental screening. The rate of contact sensitization between atopics and non-atopics was not significant (p>0.05. Conclusion: We suggest in presence of mucositis and/or occupational dermatoses using supplemental series in addition to T.R.U.E. test would be more beneficial in identifing the

  19. The Effect of Spinal Tap Test on Different Sensory Modalities of Postural Stability in Idiopathic Normal Pressure Hydrocephalus

    Directory of Open Access Journals (Sweden)

    Katrin Abram

    2016-09-01

    Full Text Available Background/Aims: Postural instability in patients with normal pressure hydrocephalus (NPH is a most crucial symptom leading to falls with secondary complications. The aim of the current study was to evaluate the therapeutic effect of spinal tap on postural stability in these patients. Methods: Seventeen patients with clinical symptoms of NPH were examined using gait scale, computerized dynamic posturography (CDP, and neuropsychological assessment. Examinations were done before and after spinal tap test. Results: The gait score showed a significant improvement 24 h after spinal tap test in all subtests and in the sum score (p Conclusion: Postural stability in NPH is predominantly affected by deficient vestibular functions, which did not improve after spinal tap test. Conditions which improved best were mainly independent from visual control and are based on proprioceptive functions.

  20. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2013-05-29

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and net generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of antifoam agents was assessed with most of the simulants. Orifices included round holes and

  1. Evaluation of the screening test results before marriage

    Directory of Open Access Journals (Sweden)

    Süleyman Durmaz

    2011-09-01

    Full Text Available Objectives: Human immunodeficiency virus (HIV, Hepatitis B and Hepatitis C viruses and Treponema pallidum are parenterally and sexually transmitted infection agents. Screening test is made before marriage to pre-marital couples legally under the relevant legislation and legal procedures in our country; applicants are evaluated in terms of sexually transmitted diseases. The aim of this study is to evaluate pre-marital test results for HBsAg, anti-HCV, anti-HIV I/II and Treponema pallidum.Materials and methods: To make screening test before marriage, randomized 117 patients who were applied to Kızıltepe General Hospital of Infectious Diseases and Clinical Microbiology, were included in this study between January 2011 and March 2011. Of these patients, 64 were women (average age 24.7±5.7, and 55 were males (mean age 24.7±4.7. HBsAg, anti-HCV and anti-HIV I/II tests of the patients were studied by macro-ELISA device (ECIQ Vitros, Ortho Clinical Diagnostics, USA, screening of anti-Treponema pallidum IgG, IgA and IgM antibodies were studied by immunochromatographic rapid test (syphilis syphilis 3.0, Standard Diagnostics, inc. Korea.Results: Of the 119 patients, five patients (4.2% were positive for HBsAg (3 male and 2 female. Anti-HCV, anti-HIV I/II and anti-Treponema pallidum antibodies were negative in all patients.Conclusion: HBsAg test result which was obtained in present study has been found consistent with HBsAg positivity rate in our region. As a result of screening test that was done before marriage will continue to believe that the increased importance of the prevention of sexually transmitted diseases. J Clin Exp Invest 2011; 2 (3: 292-294.

  2. Healthy Efficient New Gas Homes (HENGH) Pilot Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wanyu R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Maddalena, Randy L [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hotchi, Toshifumi [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-05-01

    The Healthy Efficient New Gas Homes (HENGH) is a field study that will collect data on ventilation systems and indoor air quality (IAQ) in new California homes that were built to 2008 Title 24 standards. A pilot test was performed to help inform the most time and cost effective approaches to measuring IAQ in the 100 test homes that will be recruited for this study. Two occupied, single-family detached homes built to 2008 Title 24 participated in the pilot test. One of the test homes uses exhaust-only ventilation provided by a continuous exhaust fan in the laundry room. The other home uses supply air for ventilation. Measurements of IAQ were collected for two weeks. Time-resolved concentrations of particulate matter (PM), nitrogen dioxide (NO2), carbon dioxide (CO2), carbon monoxide (CO), and formaldehyde were measured. Measurements of IAQ also included time-integrated concentrations of volatile organic compounds (VOCs), volatile aldehydes, and NO2. Three perfluorocarbon tracers (PFTs) were used to estimate the dilution rate of an indoor emitted air contaminant in the two pilot test homes. Diagnostic tests were performed to measure envelope air leakage, duct leakage, and airflow of range hood, exhaust fans, and clothes dryer vent when accessible. Occupant activities, such as cooking, use of range hood and exhaust fans, were monitored using various data loggers. This document describes results of the pilot test.

  3. Results of assembly test of HTTR reactor internals

    International Nuclear Information System (INIS)

    Maruyama, S.; Saikusa, A.; Shiozawa, S.; Tsuji, N.; Miki, T.

    1996-01-01

    The assembly test of the HTTR actual reactor internals had been carried out at the works, prior to their installation in the actual reactor pressure vessel(RPV) at the construction site. The assembly test consists of several items such as examining fabricating precision of each component and alignment of piled-up structures, measuring circumferential coolant velocity profile in the passage between the simulated RPV and the reactor internals as well as under the support plates, measuring by-pass flow rate through gaps between the reactor internals, and measuring the binding force of the core restraint mechanism. Results of the test showed good performance of the HTTR reactor internals. Installation of the reactor internals in the actual RPV was started at the construction site of HTTR in April, 1995. In the installation process, main items of the assembly test at the works were repeated to investigate the reproducibility of installation. (author). 5 refs, 11 figs

  4. Results from the 1999 Beam Test of a Preshower Prototype

    CERN Document Server

    Aspell, Paul; Bloch, Philippe; Bourotte, Jean; Domeniconi, Jacques; Peisert, Anna; Evangelou, Ioannis; Kloukinas, Kostas; Kyriakis, Aristotelis; Loos, Robert; Loukas, Demetrios; Mousa, Jehad; Peron, Franck; Reynaud, Serge; Sirunyan, Albert M; Tournefier, Edwige; Van Hove, Alain; Zamiatin, Nikolai

    2000-01-01

    At the end of June 1999 a test of a preshower prototype, equipped with real-size detectors and LHC-style electronics, was tested in the H4 beam at CERN in front of a matrix of "Endcap" crystals. Data were taken with a variety of incident electron energies, and three angles of incidence ( to simulate different regions of the CMS endcaps). The prototype functioned well, with a very small startup period and operated successfully for the duration of the test ( ~ 1 week) without intervention. Good agreement has been found between data and a GEANT-3 based simulation, and the absolute results are promising. Plans are presented for a further test of the prototype in 2000 in the H2 beam inside the 3T magnet.

  5. LWR aerosol containment experiments (LACE) program and initial test results

    International Nuclear Information System (INIS)

    Muhlestein, L.D.; Hilliard, R.K.; Bloom, G.R.; McCormack, J.D.; Rahn, F.J.

    1985-01-01

    The LWR aerosol containment experiments (LACE) program is described. The LACE program is being performed at the Hanford Engineer Development Laboratory (operated by Westinghouse Hanford Company) and the initial tests are sponsored by EPRI. The objectives of the LACE program are: to demonstrate, at large-scale, inherent radioactive aerosol retention behavior for postulated high consequence LWR accident situations; and to provide a data base to be used for aerosol behavior . Test results from the first phase of the LACE program are presented and discussed. Three large-scale scoping tests, simulating a containment bypass accident sequence, demonstrated the extent of agglomeration and deposition of aerosols occurring in the pipe pathway and vented auxiliary building under realistic accident conditions. Parameters varied during the scoping tests were aerosol type and steam condensation

  6. Selected Test Results from the Encell Technology Nickel Iron Battery

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Summer Kamal Rhodes [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Baca, Wes Edmund [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Avedikian, Kristan [Encell Technology, Alachua, FL (United States)

    2014-09-01

    The performance of the Encell Nickel Iron (NiFe) battery was measured. Tests included capacity, capacity as a function of rate, capacity as a function of temperature, charge retention (28-day), efficiency, accelerated life projection, and water refill evaluation. The goal of this work was to evaluate the general performance of the Encell NiFe battery technology for stationary applications and demonstrate the chemistry's capabilities in extreme conditions. Test results have indicated that the Encell NiFe battery technology can provide power levels up to the 6C discharge rate, ampere-hour efficiency above 70%. In summary, the Encell batteries have met performance metrics established by the manufacturer. Long-term cycle tests are not included in this report. A cycle test at elevated temperature was run, funded by the manufacturer, which Encell uses to predict long-term cycling performance, and which passed their prescribed metrics.

  7. Small-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Mahoney, Lenna A.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, Garrett N.; Kurath, Dean E.; Buchmiller, William C.; Smith, Dennese M.; Blanchard, Jeremy; Song, Chen; Daniel, Richard C.; Wells, Beric E.; Tran, Diana N.; Burns, Carolyn A.

    2012-11-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  8. Wind tunnel test IA300 analysis and results, volume 1

    Science.gov (United States)

    Kelley, P. B.; Beaufait, W. B.; Kitchens, L. L.; Pace, J. P.

    1987-01-01

    The analysis and interpretation of wind tunnel pressure data from the Space Shuttle wind tunnel test IA300 are presented. The primary objective of the test was to determine the effects of the Space Shuttle Main Engine (SSME) and the Solid Rocket Booster (SRB) plumes on the integrated vehicle forebody pressure distributions, the elevon hinge moments, and wing loads. The results of this test will be combined with flight test results to form a new data base to be employed in the IVBC-3 airloads analysis. A secondary objective was to obtain solid plume data for correlation with the results of gaseous plume tests. Data from the power level portion was used in conjunction with flight base pressures to evaluate nominal power levels to be used during the investigation of changes in model attitude, eleveon deflection, and nozzle gimbal angle. The plume induced aerodynamic loads were developed for the Space Shuttle bases and forebody areas. A computer code was developed to integrate the pressure data. Using simplified geometrical models of the Space Shuttle elements and components, the pressure data were integrated to develop plume induced force and moments coefficients that can be combined with a power-off data base to develop a power-on data base.

  9. A comparison of short-term dispersion estimates resulting from various atmospheric stability classification methods

    International Nuclear Information System (INIS)

    Mitchell, A.E. Jr.

    1982-01-01

    Four methods of classifying atmospheric stability class are applied at four sites to make short-term (1-h) dispersion estimates from a ground-level source based on a model consistent with U.S. Nuclear Regulatory Commission practice. The classification methods include vertical temperature gradient, standard deviation of horizontal wind direction fluctuations (sigma theta), Pasquill-Turner, and modified sigma theta which accounts for meander. Results indicate that modified sigma theta yields reasonable dispersion estimates compared to those produced using methods of vertical temperature gradient and Pasquill-Turner, and can be considered as a potential economic alternative in establishing onsite monitoring programs. (author)

  10. Guidelines to Interpret Results of Mechanical Blade Test

    International Nuclear Information System (INIS)

    Arias Vega, F.; Sanz Martin, J. C.

    1999-01-01

    This report shows the interpretation of full scale rotor blade test results and describes the engineering testing models and coefficients for any feasible rotor blade design, in order to accept and to certify any final manufactured blade as an allowable product, fit for use and working with a completely security during all the wind turbines lifetime. This work was carried out at the Wind Energy Division of the CIEMAT.DER and it is based on the authors technical experience in this field, after many years working on testing blades. Also, this paper contains results of the European wind turbine Standards II relevant to the European Project: JOULE III R.D. where the Wind Energy Division took part as participant too. (Author)

  11. Test-beam results of a SOI pixel detector prototype

    CERN Document Server

    Bugiel, Roma; Dannheim, Dominik; Fiergolski, Adrian; Hynds, Daniel; Idzik, Marek; Kapusta, P; Kucewicz, Wojciech; Munker, Ruth Magdalena; Nurnberg, Andreas Matthias

    2018-01-01

    This paper presents the test-beam results of a monolithic pixel-detector prototype fabricated in 200 nm Silicon-On-Insulator (SOI) CMOS technology. The SOI detector was tested at the CERN SPS H6 beam line. The detector is fabricated on a 500 μm thick high-resistivity float- zone n-type (FZ-n) wafer. The pixel size is 30 μm × 30 μm and its readout uses a source- follower configuration. The test-beam data are analysed in order to compute the spatial resolution and detector efficiency. The analysis chain includes pedestal and noise calculation, cluster reconstruction, as well as alignment and η-correction for non-linear charge sharing. The results show a spatial resolution of about 4.3 μm.

  12. Results for the Brine Evaporation Bag (BEB) Brine Processing Test

    Science.gov (United States)

    Delzeit, Lance; Flynn, Michael; Fisher, John; Shaw, Hali; Kawashima, Brian; Beeler, David; Howard, Kevin

    2015-01-01

    The recent Brine Processing Test compared the NASA Forward Osmosis Brine Dewatering (FOBD), Paragon Ionomer Water Processor (IWP), UMPQUA Ultrasonic Brine Dewatering System (UBDS), and the NASA Brine Evaporation Bag (BEB). This paper reports the results of the BEB. The BEB was operated at 70 deg C and a base pressure of 12 torr. The BEB was operated in a batch mode, and processed 0.4L of brine per batch. Two different brine feeds were tested, a chromic acid-urine brine and a chromic acid-urine-hygiene mix brine. The chromic acid-urine brine, known as the ISS Alternate Pretreatment Brine, had an average processing rate of 95 mL/hr with a specific power of 5kWhr/L. The complete results of these tests will be reported within this paper.

  13. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  14. The Higgs boson and Top quark masses as tests of Electroweak Vacuum Stability

    Energy Technology Data Exchange (ETDEWEB)

    Masina, Isabella

    2013-04-15

    The measurements of the Higgs boson and top quark masses can be used to extrapolate the Standard Model Higgs potential at energies up to the Planck scale. Adopting a Next-to-Next-to-Leading Order renormalization procedure, we argue that electroweak vacuum stability is at present allowed, discuss the associated theoretical and experimental errors and the prospects for its future tests.

  15. Temporal Stability of Strength-Based Assessments: Test-Retest Reliability of Student and Teacher Reports

    Science.gov (United States)

    Romer, Natalie; Merrell, Kenneth W.

    2013-01-01

    This study focused on evaluating the temporal stability of self-reported and teacher-reported perceptions of students' social and emotional skills and assets. We used a test-retest reliability procedure over repeated administrations of the child, adolescent, and teacher versions of the "Social-Emotional Assets and Resilience Scales".…

  16. Comparison of genome stability in two pig breeds by using the sister chromatid exchange (SCE test

    Directory of Open Access Journals (Sweden)

    V. Barbieri

    2010-01-01

    Full Text Available The sister chromatid exchange (SCE test has been used to detect genome stability in humans (Chaganti, 1974 and the main livestock species (Ciotola et al., 2004; Di Meo et al., 2000; Di Berardino et al., 1979, and to discover DNA damage caused by a variety of natural and artificial chemical compounds (Iannuzzi et al., 1990.

  17. Eye-head stabilization mechanism for a humanoid robot tested on human inertial data

    DEFF Research Database (Denmark)

    Vannucci, Lorenzo; Falotico, Egidio; Tolu, Silvia

    2016-01-01

    they keep the image stationary on the retina. In this work we present the first complete model of eye-head stabilization based on the coordination of VCR and VOR. The model is provided with learning and adaptation capabilities based on internal models. Tests on a simulated humanoid platform replicating...

  18. Postural stability in patients with decompression sickness evaluated by means of Quantitative Romberg testing

    DEFF Research Database (Denmark)

    Hedetoft, Morten; Hyldegaard, Ole

    2015-01-01

    OBJECTIVE: The present study was designed to retrospectively evaluate the use of quantitative Romberg's testing on postural stability during the course of hyperbaric oxygen (HBO2) therapy in patients presenting with decompression sickness (DCS). METHODS: The Quantitative Romberg test was used...... obtained with the Quantitative Romberg test were observed in the group of DCS with vertigo relative to DCS without vertigo and healthy controls. A stepwise improvement in postural instability for DCS patients with vertigo was found following HBO2 therapy. After three treatments of HBO2, postural stability...... was found to be within the normal range of healthy controls. CONCLUSIONS: The Quantitative Romberg test offers the the clinician a fast, reliable and objective set of parametrical data to document postural instability in patients with either confirmed or suspected DCS....

  19. Interpretation of Chemical Pathology Test Results in Paediatrics ...

    African Journals Online (AJOL)

    At any time we interprete paediatric chemical pathology test results we must take into consideration a number of factors, which are related with and restricted to paediatric patients. Such factors include the paediatric patient's age that may change from prematurity to above 18 years, and the paediatric patient's body weight ...

  20. Pattern Of Skin Prick Allergy Test Results In Enugu | Mgbor ...

    African Journals Online (AJOL)

    In this study we report on pattern of allergy prick skin test results found among atopic patients attending the department of otorhinolargngology of the University of Nigeria Teaching Hospital Enugu and Hansa Clinics, Enugu and propose ways of minimizing the exposure of the population to allergens. Material and method

  1. 49 CFR 199.109 - Review of drug testing results.

    Science.gov (United States)

    2010-10-01

    ... assistance in resolving problems with drug abuse, does not refer the covered employee to the substance abuse... person under contract to provide treatment for drug problems on behalf of the operator; (3) The sole... 49 Transportation 3 2010-10-01 2010-10-01 false Review of drug testing results. 199.109 Section...

  2. Recent results on the RIA test in IGR reactor

    International Nuclear Information System (INIS)

    Asmolov, V.; Yegorova, L.

    1997-01-01

    At the 23d WRSM meeting the data base characterizing results of VVER high burnup fuel rods tests under reactivity-initiated accident (RIA) conditions was presented. Comparison of PWR and VVER failure thresholds was given also. Additional analysis of the obtained results was being carried out during 1996. The results of analysis show that the two different failure mechanisms were observed for PWR and VVER fuel rods. Some factors which can be as the possible reasons of these differences are presented. First of them is the state of preirradiated cladding. Published test data for PWR high burnup fuel rods demonstrated that the PWR high burnup fuel rods failed at the RIA test are characterized by very high level of oxidation and hydriding for the claddings. Corresponding researches were performed at Institute of Atomic Reactors (RLAR, Dimitrovgrad, Russia) for large set of VVER high burnup fuel rods. Results of these investigations show that preirradiated commercial Zr-1%Nb claddings practically keep their initial levels of oxidation and H 2 concentration. Consequently the VVER preirradiated cladding must keep the high level of mechanical properties. The second reason leading to differences between failure mechanisms for two types of high burnup fuel rods can be the test conditions. Now such kind of analysis have been performed by two methods

  3. ATLAS Transition Radiation Tracker test-beam results

    Science.gov (United States)

    Akesson, T.; Arik, E.; Baker, K.; Baron, S.; Benjamin, D.; Bertelsen, H.; Bondarenko, V.; Bytchkov, V.; Callahan, J.; Capeans, M.; Cardiel-Sas, L.; Catinaccio, A.; Cetin, S. A.; Cwetanski, P.; Dam, M.; Danielsson, H.; Dittus, F.; Dolgoshein, B.; Dressnandt, N.; Driouichi, C.; Ebenstein, W. L.; Eerola, P.; Farthouat, P.; Fedin, O.; Froidevaux, D.; Gagnon, P.; Grichkevitch, Y.; Grigalashvili, N.; Hajduk, Z.; Hansen, P.; Kayumov, F.; Keener, P. T.; Kekelidze, G.; Khristatchev, A.; Konovalov, S.; Koudine, L.; Kovalenko, S.; Kowalski, T.; Kramarenko, V. A.; Kruger, K.; Laritchev, A.; Lichard, P.; Luehring, F.; Lundberg, B.; Maleev, V.; Markina, I.; McFarlane, K.; Mialkovski, V.; Mitsou, V. A.; Mindur, B.; Morozov, S.; Munar, A.; Muraviev, S.; Nadtochy, A.; Newcomer, F. M.; Ogren, H.; Oh, S. H.; Oleshko, S.; Olszowska, J.; Passmore, S.; Patritchev, S.; Peshekhonov, V.; Petti, R.; Price, M.; Rembser, C.; Rohne, O.; Romaniouk, A.; Rust, D. R.; Ryabov, Yu.; Schegelsky, V.; Seliverstov, D.; Shin, T.; Shmeleva, A.; Smirnov, S.; Sosnovtsev, V.; Soutchkov, V.; Spiridenkov, E.; Tikhomirov, V.; Van Berg, R.; Vassilakopoulos, V.; Vassilieva, L.; Wang, C.; Williams, H. H.; Zalite, A.

    2004-04-01

    Several prototypes of the Transition Radiation Tracker for the ATLAS experiment at the LHC have been built and tested at the CERN SPS accelerator. Results from detailed studies of the straw-tube hit registration efficiency and drift-time measurements and of the pion and electron spectra without and with radiators are presented.

  4. Using soil test results to determine fertilizer applications

    Science.gov (United States)

    C. B. Davey

    2002-01-01

    Using soil test results is a very useful practice IF the sample(s) of soil are good representations of the nursery soil. The lab results can be no more accurate than the samples submitted, and IF you know the texture of the nursery soil, and IF you know which soil extractant was used by the lab, and IF you know what crop is to be grown, and IF, for trees, which species...

  5. Automated result analysis in radiographic testing of NPPs' welded joints

    International Nuclear Information System (INIS)

    Skomorokhov, A.O.; Nakhabov, A.V.; Belousov, P.A.

    2009-01-01

    The article presents development results of algorithms for automated image interpretation of NPP welded joints radiographic inspection. The developed algorithms are based on state-of-the-art pattern recognition methods. The paper covers automatic radiographic image segmentation, defects detection and their parameters evaluation issues. The developed algorithms testing results for actual radiographic images of welded joints with significant variation of defects parameters are given [ru

  6. Large-Scale Spray Releases: Initial Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Bontha, Jagannadha R.; Daniel, Richard C.; Kurath, Dean E.; Adkins, Harold E.; Billing, Justin M.; Burns, Carolyn A.; Davis, James M.; Enderlin, Carl W.; Fischer, Christopher M.; Jenks, Jeromy WJ; Lukins, Craig D.; MacFarlan, Paul J.; Shutthanandan, Janani I.; Smith, Dennese M.

    2012-12-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. Two key technical areas were identified where testing results were needed to improve the technical basis by reducing the uncertainty due to extrapolating existing literature results. The first technical need was to quantify the role of slurry particles in small breaches where the slurry particles may plug and result in substantially reduced, or even negligible, respirable fraction formed by high-pressure sprays. The second technical need was to determine the aerosol droplet size distribution and volume from prototypic breaches and fluids, specifically including sprays from larger breaches with slurries where data from the literature are scarce. To address these technical areas, small- and large-scale test stands were constructed and operated with simulants to determine aerosol release fractions and generation rates from a range of breach sizes and geometries. The properties of the simulants represented the range of properties expected in the WTP process streams and included water, sodium salt solutions, slurries containing boehmite or gibbsite, and a hazardous chemical simulant. The effect of anti-foam agents was assessed with most of the simulants. Orifices included round holes and

  7. Graphite electrode arc melter demonstration Phase 2 test results

    Energy Technology Data Exchange (ETDEWEB)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; O`Connor, W.K.; Oden, L.L.; Turner, P.C.

    1996-06-01

    Several U.S. Department of Energy organizations and the U.S. Bureau of Mines have been collaboratively conducting mixed waste treatment process demonstration testing on the near full-scale graphite electrode submerged arc melter system at the Bureau`s Albany (Oregon) Research Center. An initial test series successfully demonstrated arc melter capability for treating surrogate incinerator ash of buried mixed wastes with soil. The conceptual treatment process for that test series assumed that buried waste would be retrieved and incinerated, and that the incinerator ash would be vitrified in an arc melter. This report presents results from a recently completed second series of tests, undertaken to determine the ability of the arc melter system to stably process a wide range of {open_quotes}as-received{close_quotes} heterogeneous solid mixed wastes containing high levels of organics, representative of the wastes buried and stored at the Idaho National Engineering Laboratory (INEL). The Phase 2 demonstration test results indicate that an arc melter system is capable of directly processing these wastes and could enable elimination of an up-front incineration step in the conceptual treatment process.

  8. Graphite electrode arc melter demonstration Phase 2 test results

    International Nuclear Information System (INIS)

    Soelberg, N.R.; Chambers, A.G.; Anderson, G.L.; O'Connor, W.K.; Oden, L.L.; Turner, P.C.

    1996-06-01

    Several U.S. Department of Energy organizations and the U.S. Bureau of Mines have been collaboratively conducting mixed waste treatment process demonstration testing on the near full-scale graphite electrode submerged arc melter system at the Bureau's Albany (Oregon) Research Center. An initial test series successfully demonstrated arc melter capability for treating surrogate incinerator ash of buried mixed wastes with soil. The conceptual treatment process for that test series assumed that buried waste would be retrieved and incinerated, and that the incinerator ash would be vitrified in an arc melter. This report presents results from a recently completed second series of tests, undertaken to determine the ability of the arc melter system to stably process a wide range of open-quotes as-receivedclose quotes heterogeneous solid mixed wastes containing high levels of organics, representative of the wastes buried and stored at the Idaho National Engineering Laboratory (INEL). The Phase 2 demonstration test results indicate that an arc melter system is capable of directly processing these wastes and could enable elimination of an up-front incineration step in the conceptual treatment process

  9. Space Launch System Base Heating Test: Experimental Operations & Results

    Science.gov (United States)

    Dufrene, Aaron; Mehta, Manish; MacLean, Matthew; Seaford, Mark; Holden, Michael

    2016-01-01

    NASA's Space Launch System (SLS) uses four clustered liquid rocket engines along with two solid rocket boosters. The interaction between all six rocket exhaust plumes will produce a complex and severe thermal environment in the base of the vehicle. This work focuses on a recent 2% scale, hot-fire SLS base heating test. These base heating tests are short-duration tests executed with chamber pressures near the full-scale values with gaseous hydrogen/oxygen engines and RSRMV analogous solid propellant motors. The LENS II shock tunnel/Ludwieg tube tunnel was used at or near flight duplicated conditions up to Mach 5. Model development was based on the Space Shuttle base heating tests with several improvements including doubling of the maximum chamber pressures and duplication of freestream conditions. Test methodology and conditions are presented, and base heating results from 76 runs are reported in non-dimensional form. Regions of high heating are identified and comparisons of various configuration and conditions are highlighted. Base pressure and radiometer results are also reported.

  10. MICRO PIN ARRAY DETECTOR (MIPA): FIRST TEST RESULTS.

    Energy Technology Data Exchange (ETDEWEB)

    REHAK,P.; SMITH,G.C.; WARREN,J.B.; YU,B.

    1999-06-28

    A novel gas proportional detector, consisting of an array of pins immersed into a cathode made out of closely packed hexagonals has been developed. The resulting geometry of the detector is 3 dimensional. Electron multiplication is limited to a region in close proximity to the tip of each pin, where the electric field decreases with distance from the pin at a rate faster than 1/r, the rate that exists in a traditional wire chamber. The multiplication region is limited to a small part of the detector volume leading to stability of operation up to high charge gas gains. The amplification region is located far enough from any dielectric surface that the gas gain is insensitive to the charge state of the surface, a significant benefit compared with many other micro-pattern detectors. The microscopic dimensions of the individual pins of the array result in signals whose total duration is about a microsecond. Two identical, but opposite polarity signals are detected, one on the pin and one on the cathode. Both signals can be used by two independent, charge division, read-out systems to obtain unambiguous x-y position information of the primary ionization.

  11. MICRO PIN ARRAY DETECTOR (MIPA): FIRST TEST RESULTS.

    Energy Technology Data Exchange (ETDEWEB)

    REHAK,P.; SMITH,G.C.; WARREN,J.B.; YU,B.

    1999-06-28

    A novel gas proportional detector, consisting of an array of pins immersed into a cathode made out of closely packed hexagonals has been developed. The resulting geometry of the detector is 3 dimensional. Electron multiplication is limited to a region in close proximity to the tip of each pin, where the electric field decreases with distance from the pin at a rate faster than l/r, the rate that exists in a traditional wire chamber. The multiplication region is limited to a small part of the detector volume leading to stability of operation up to high charge gas gains. The amplification region is located far enough from any dielectric surface that the gas gain is insensitive to the charge state of the surface, a significant benefit compared with many other micro-pattern detectors. The microscopic dimensions of the individual pins of the array result in signals whose total duration is about a microsecond. Two identical, but opposite polarity signals are detected, one on the pin and one on the cathode. Both signals can be used by two independent, charge division, read-out systems to obtain unambiguous x-y position information of the primary ionization.

  12. Developing a flammability test system for sunglasses: results

    Science.gov (United States)

    Magri, Renan; Ventura, Liliane

    2015-03-01

    Sunglasses popularity has increased tremendously. This fact has further led to the need of certificating sunglasses accordingly to the standard NBR 15111 to protect consumers from damages and secondary hazards caused by sunglasses use. The ongoing need comes at the expense that none certification institution in Brazil performs all tests procedures required by the NBR 15111. This manuscript presents the development of a flammability test system for sunglasses and the assessments results. The equipment for testing flammability developed is made of an electrical furnace with a thermocouple and electronic system that maintains the temperature in 650 ºC. This furnace heats a steel rod used for testing flammability. A steel cable connected to a linear actuator drives the rod. The main control system is based on an ARM Cortex M0 microcontroller and we developed a PC interface in LabView to acquire data and store it. The equipment built also has a control panel with a push button, status LEDs and temperature indicator. We performed flammability tests in 45 sunglasses: 45 lenses and 45 frames using the equipment described. None of the samples ignited or continued to glow when the test has finished, however, all polycarbonate samples were melted in the contact region with the steel rod. All samples complied with the NBR 15111. The proof argues that the polycarbonate is extremely resistant to ignition.

  13. Design, ancillary testing, analysis and fabrication data for the advanced composite stabilizer for Boeing 737 aircraft. Volume 1: Technical summary

    Science.gov (United States)

    Aniversario, R. B.; Harvey, S. T.; Mccarty, J. E.; Parsons, J. T.; Peterson, D. C.; Pritchett, L. D.; Wilson, D. R.; Wogulis, E. R.

    1983-01-01

    The horizontal stabilizer of the 737 transport was redesigned. Five shipsets were fabricated using composite materials. Weight reduction greater than the 20% goal was achieved. Parts and assemblies were readily produced on production-type tooling. Quality assurance methods were demonstrated. Repair methods were developed and demonstrated. Strength and stiffness analytical methods were substantiated by comparison with test results. Cost data was accumulated in a semiproduction environment. FAA certification was obtained.

  14. Stability of puppy reaction to traditional puppy aptitude test under experimentally reared condtions

    OpenAIRE

    Ishikawa, Keisuke; Eguchi, Yusuke; Uetake, Katsuji; Tnaka, Toshio

    2010-01-01

    The puppy aptitude test (PAT) is a general method for choosing a puppy. However, the reliability of the test has been in doubt because of its lack of a scientific base. In this report, we conducted PAT and some other behavioral tests before and after the establishment of socialization in order to investigate the stability of behavioral traits of puppies. Ten puppies were tested of eleven items on PAT at 57 and 140 days of age. The puppy’s behavior was videotaped and rated by four people using...

  15. RESULTS OF COMPRESSION TESTING ON PSEUDO-COHESIVE SOIL

    Directory of Open Access Journals (Sweden)

    Ofrikhter Vadim Grigor’evich

    2015-09-01

    Full Text Available Natural non-treated sand reinforced with randomly oriented short polypropylene fibers of 12 mm in length was tested to determine creep characteristics. This study is a part of the research aimed at encouraging fibrosand (FRS application in subsoils, embankments and retaining wall constructions. Fiber content was accounted for 0.93 %. Twin specimens were put to creep tests (1-D compression using the two curve method. The test results were analyzed and checked with the use of ageing, hardening and hereditary creep theories. On the basis of approximation of the test results the creep deformation equation at constant stress for tested fibrosand was obtained. The assessment of fibrosand secondary compression was carried out by the FORE method. As a result, the value of the void ratio by the end of the secondary compression had been eu=0.7041. For determination of the beginning of the secondary compression the rate equation was superimposed on the empirical curve. The point of the graph divergence is the beginning of the secondary compression process. The secondary compression had begun by the time moment being equal to 9360 min. The void ratio by the beginning of the secondary compression had amounted to 0.70574. Fibrosand is a specific type of improved soil relating to so-called pseudo-cohesive soil. This type of soil is characterized by cohesion like cohesive soils, but, at the same time, by the filtration coefficient of about 1 m per day like non-cohesive soils. Pseudo-cohesive soil testing helps to understand the distinctive features of the stress-strain state of this kind of materials. Municipal solid waste also relates to them.

  16. Long Term Corrosion/Degradation Test Six Year Results

    Energy Technology Data Exchange (ETDEWEB)

    M. K. Adler Flitton; C. W. Bishop; M. E. Delwiche; T. S. Yoder

    2004-09-01

    The Subsurface Disposal Area (SDA) of the Radioactive Waste Management Complex (RWMC) located at the Idaho National Engineering and Environmental Laboratory (INEEL) contains neutron-activated metals from non-fuel, nuclear reactor core components. The Long-Term Corrosion/Degradation (LTCD) Test is designed to obtain site-specific corrosion rates to support efforts to more accurately estimate the transfer of activated elements to the environment. The test is using two proven, industry-standard methods—direct corrosion testing using metal coupons, and monitored corrosion testing using electrical/resistance probes—to determine corrosion rates for various metal alloys generally representing the metals of interest buried at the SDA, including Type 304L stainless steel, Type 316L stainless steel, Inconel 718, Beryllium S200F, Aluminum 6061, Zircaloy-4, low-carbon steel, and Ferralium 255. In the direct testing, metal coupons are retrieved for corrosion evaluation after having been buried in SDA backfill soil and exposed to natural SDA environmental conditions for times ranging from one year to as many as 32 years, depending on research needs and funding availability. In the monitored testing, electrical/resistance probes buried in SDA backfill soil will provide corrosion data for the duration of the test or until the probes fail. This report provides an update describing the current status of the test and documents results to date. Data from the one-year and three-year results are also included, for comparison and evaluation of trends. In the six-year results, most metals being tested showed extremely low measurable rates of general corrosion. For Type 304L stainless steel, Type 316L stainless steel, Inconel 718, and Ferralium 255, corrosion rates fell in the range of “no reportable” to 0.0002 mils per year (MPY). Corrosion rates for Zircaloy-4 ranged from no measurable corrosion to 0.0001 MPY. These rates are two orders of magnitude lower than those specified in

  17. Patch Test Results of 775 Patients with Allergic Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Simin Ada

    2010-12-01

    Full Text Available Background and Design: The allergens responsible for allergic contact dermatitis vary among countries and even between different geographical regions within the same country over time. It is of great importance to perform the patch test at certain intervals, to evaluate the results in different centers and to compare them afterwards. Our aim was to evaluate the patch test results in our patients with allergic contact dermatitis.Material and Method: The records of the patients with allergic contact dermatitis, who had been patch tested between May 1997 and March 2009, were analyzed retrospectively. The demographic features such as age and sex, localization of the contact dermatitis, and the patch test results were recorded. Results: Of the 775 patients, 581 (75.2% were females and 194 (25% males. Of all patients, 735 were patch tested with the European Standard Series, 318 - with both the European Standard Series and cosmetic series, and 40-with cosmetic series alone. Of the patients tested with the European Standard Series, 255 (34.7% had at least one positive reaction. The most frequent allergen in the European Standard Series was nickel sulfate (17.3%, followed by cobalt chloride (7.2%, potassium dichromate (3%, fragrance mix (2.9%, and p-phenylenediamine base (2.6%. Of the 358 patients tested with cosmetic series, 82 (22.9% had at least one positive reaction. The 5 most frequently observed cosmetic series allergens were octyl gallate (3.9%, thimerosal (2.2%, sorbitan sesquioleate (2%, Euxyl K 400 (2% and methyldibromo glutaronitrile (1.4%. Conclusion: Our study shows the contact allergen profile of our center over 12 years. The most common allergens and their frequency differ between centers in various cities in Turkey. Those geographical differences should be re-evaluated by further studies performed in the certain time period. The high frequency of reactions to octyl gallate is an important finding in patients suspected of cosmetic allergy

  18. PISA TESTS IN LATIN AMERICA: RESULTS IN CONTEXT

    Directory of Open Access Journals (Sweden)

    Guillermina Tiramonti

    2014-05-01

    Full Text Available The educational reforms implemented in Latin America in the ‘90s introduced changes in the modes of regulation of educational systems based on the adoption of mechanisms for assessing student achievement. Since 2000, eight Latin-American countries (Argentina, Chile, Uruguay, Colombia, Brazil, Costa Rica, Mexico and Peru are involved in the PISA tests. The article presents a brief review of the social and educational situation of the Region, relevant for the interpretation and comparative analysis of the results of these tests that is presented below.

  19. 688,112 statistical results : Content mining psychology articles for statistical test results

    NARCIS (Netherlands)

    Hartgerink, C.H.J.

    2016-01-01

    In this data deposit, I describe a dataset that is the result of content mining 167,318 published articles for statistical test results reported according to the standards prescribed by the American Psychological Association (APA). Articles published by the APA, Springer, Sage, and Taylor & Francis

  20. Stability Result For Dynamic Inversion Devised to Control Large Flexible Aircraft

    Science.gov (United States)

    Gregory, Irene M.

    2001-01-01

    High performance aircraft of the future will be designed lighter, more maneuverable, and operate over an ever expanding flight envelope. One of the largest differences from the flight control perspective between current and future advanced aircraft is elasticity. Over the last decade, dynamic inversion methodology has gained considerable popularity in application to highly maneuverable fighter aircraft, which were treated as rigid vehicles. This paper is an initial attempt to establish global stability results for dynamic inversion methodology as applied to a large, flexible aircraft. This work builds on a previous result for rigid fighter aircraft and adds a new level of complexity that is the flexible aircraft dynamics, which cannot be ignored even in the most basic flight control. The results arise from observations of the control laws designed for a new generation of the High-Speed Civil Transport aircraft.

  1. Fecal Collection and Stabilization Methods for Improved Fecal DNA Test for Colorectal Cancer in a Screening Setting

    Directory of Open Access Journals (Sweden)

    Francesca Maria Carozzi

    2013-01-01

    Full Text Available Early detection of CRC and adenomas reduces CRC-related mortality. The optimal screening test for CRC is still a subject of debate, and molecular stool sample analysis could provide a valid alternative to conventional methods in terms of compliance and practicability. Seven fecal DNA storage systems were evaluated in two successive phases. In the first phase of the study was selected the preservative buffer able to ensure the best human DNA recovery. In the second phase was evaluated human DNA stability, amplificability and integrity in DNA extracted from selected buffer. Results showed that the best performance was obtained in samples stored in 100 mM EDTA buffer and Genefec buffer. Likewise buffer addition yielded a significant increase in DNA stability and integrity without PCR inhibition, compared to the matched aliquots with no buffer added. Our study shows that samples collected in stabilization solution stabilize DNA so that intact nucleic acids, are more effectively detectable in the molecular assay. DNA buffer preservation and storage conditions could be useful to guarantee the most consistent yield in human DNA. Stabilization buffer addition to stool samples prior to transport presents an easily implemented solution that appears to be highly effective. Overall DNA extracted from faeces preserved in preservative buffer can feasibility been used for molecular analysis leading to an increase of assay sensitivity.

  2. Lab scale testing of novel natural analog in situ stabilization agents

    International Nuclear Information System (INIS)

    Shaw, P.

    1997-01-01

    This report summarizes the laboratory-scale test results on several novel in situ treatment and stabilization agents for buried hazardous and radioactive waste. Paraffin, hematite and phosphate materials were examined when combined with soil and other wastes representative of what might be present at buried waste DOE sites. Hematite was made from the reaction of agricultural iron and lime slurries to form gypsum and iron oxide/hydroxide. Common household paraffin was melted, both with and without a zeolitic additive, waste added and then cooled. Magnesium phosphate was made from the reaction of magnesium oxide and phosphoric acid or potassium biphosphate to form, magnesium phosphate. All were tested with soil and some with additional waste sumulants such as ash, machine oil and nitrate salts. The following laboratory-generated data indicate that all waste encapsulation materials tested are appropriate materials, for field in situ testing. Compressive strengths of treated Idaho National Engineering and Environment Laboratory (INEEL) soil and the waste encapsulation material were sufficient to prevent collapse of the void space in waste, i.e., greater than the NRC 60 psi minimum. The mineralogy and microstructure of hematite was amorphous but should progress to an interlocking crystalline solid. Phosphate was crystalline with characteristics of higher temperature ceramics. Paraffin is non crystalline but encapsulates even very fine grained INEEL soils. Each agent appears to be chemically and physically inert to possible waste materials such as, nitrates and machine cutting oil. Two of the agents hematite and phosphate react favorably with ash increasing the metals retention at higher waste loadings than Portland cement. Hematite, phosphate and zeolite decrease leaching of most hazardous metals from waste when compared to untreated waste and soil. Solution pH, time for reaction initiation, and viscosity values are conducive to jet-grouting application

  3. Gold Nanoparticles: Synthesis, Stability Test, and Application for the Rice Growth

    OpenAIRE

    Wang, Aiwu; Ng, Hoi Pong; Xu, Yi; Li, Yuyu; Zheng, Yuhong; Yu, Jingping; Han, Fugui; Peng, Feng; Fu, Li

    2014-01-01

    In today’s science, with the use of nanotechnology, nanomaterials, which behave very differently from the bulk solid, can be made. One of the capable uses of nanomaterials is bioapplications which make good use of the specific properties of nanoparticles. However, since the nanoparticles will be used both in-vivo and in-vitro, their stability is an important issue to the scientists, concern. In this dissertation, we are going to test the stability of gold nanoparticles in a number of media in...

  4. Planar Pixel Sensors for the ATLAS Upgrade: Beam Tests results

    CERN Document Server

    Weingarten, J

    2012-01-01

    The performance of planar silicon pixel sensors, in development for the ATLAS Insertable B-Layer and High Luminosity LHC (HL-LHC) upgrades, has been examined in a series of beam tests at the CERN SPS facilities since 2009. Salient results are reported on the key parameters, including the spatial resolution, the charge collection and the charge sharing between adjacent cells, for different bulk materials and sensor geometries. Measurements are presented for n+-in-n pixel sensors irradiated with a range of fluences and for p-type silicon sensors with various layouts from different vendors. All tested sensors were connected via bump-bonding to the ATLAS Pixel read-out chip. The tests reveal that both n-type and p-type planar sensors are able to collect significant charge even after the lifetime fluence expected at the HL-LHC.

  5. Test beam results from the CMS electromagnetic calorimeter

    CERN Document Server

    Brunelière, R

    2004-01-01

    A precision lead tungstate crystal calorimeter is being constructed by the CMS collaboration. As a key part of the future CMS detector at the LHC, the electromagnetic calorimeter will play a major role in probing electroweak symmetry-breaking and searches for new physics. In order to check that the required performance of the electromagnetic calorimeter is attainable, every prototype is tested in real conditions within a beam of particles. In 2003 two modules of the electromagnetic calorimeter featuring the final mechanical design and electronic architecture have been tested with two different versions of the front-end electronics. In this paper a review of the main results of test beam campaigns in 2002 and 2003 are given. (7 refs).

  6. Results of the quality assurance testing program for radiopharmaceuticals 1995

    International Nuclear Information System (INIS)

    Baldas, J.; Binnyman, J.; Ivanov, Z.; Lauder, R.

    1996-07-01

    The results of the quality assurance testing conducted by the Australian Radiation Laboratory is summarised. Overall 111 batches of 27 different types of radiopharmaceuticals were tested on samples obtained through normal commercial channels. Failure to meet full specifications was observed in 10 of the 111 batches. All technetium-99m cold kits were reconstituted according to the directions in the package insert using sodium pertechnetate ( 99m Tc) injection. Radionuclidic purity has been determined at the calibration time, except for Thallous [ 201 Tl] Chloride injection where the highest impurity level up to product expiry is quoted. Non-compliance of the vial label was observed in one of the ten batches failing specification and was the sole cause of product failure for this batch. Vial label non-compliance consisted of, absence of volume in the vial. Six batches failed the biodistribution test but in no case did this involve failure of the distribution for the target organs. tabs

  7. Results of aircraft positioning tests in postprocessing using the GNSS

    Directory of Open Access Journals (Sweden)

    Henryk JAFERNIK

    2017-06-01

    Full Text Available In this paper, the results of an aircraft’s positioning in aviation during two flight tests are presented. The aircraft’s position was established using GPS data with a sample rate of 1 s in both experiments. The raw GPS data were collected by a Topcon Hiper Pro receiver, which was installed in the pilot’s cabin of a Cessna aircraft. The aircraft’s coordinates in the BLh geodetic frame were determined using the single point positioning (SPP method in gLAB software. The mathematical algorithm for the aircraft’s coordinates are also described in the article. The typical standard deviations for the aircraft’s coordinates were less than 10 m in test I and less than 30 m in test II.

  8. The Marviken critical flow test. A description and early results

    International Nuclear Information System (INIS)

    Hall, D.G.; Ericson, L.

    1978-01-01

    The Marviken critical flow tests are a multinational project designed to obtain critical flow data under conditions similar to those which might occur in a full-scale reactor loss-of-coolant accident. The test facility and procedure used to obtain critical flow data at supply pressures up to 5 MPa and at fluid conditions from 30 0 C subcooling to low-quality saturated conditions are described. Sample data of the type obtained using ruptured-pipe simulators having internal diameters up to 500 mm and length-to-diameter ratios of 1 and 3 are presented and discussed. It is concluded that the results of the tests will probably provide an important measure of the effect of piping size on the critical flow phenomenon and increase the certainty with which critical flows can be predicted in fullscale reactor calculations. (author)

  9. Initial CGE Model Results Summary Exogenous and Endogenous Variables Tests

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, Brian Keith [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Boero, Riccardo [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Rivera, Michael Kelly [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-07

    The following discussion presents initial results of tests of the most recent version of the National Infrastructure Simulation and Analysis Center Dynamic Computable General Equilibrium (CGE) model developed by Los Alamos National Laboratory (LANL). The intent of this is to test and assess the model’s behavioral properties. The test evaluated whether the predicted impacts are reasonable from a qualitative perspective. This issue is whether the predicted change, be it an increase or decrease in other model variables, is consistent with prior economic intuition and expectations about the predicted change. One of the purposes of this effort is to determine whether model changes are needed in order to improve its behavior qualitatively and quantitatively.

  10. Potential of Cowpea Variety Mixtures to Increase Yield Stability in Subsistence Agriculture: Preliminary Results

    Directory of Open Access Journals (Sweden)

    Joshua S. Okonya

    2014-01-01

    Full Text Available Cowpea Vigna unguiculata (L. Walp. is an important leafy vegetable and grain legume in Uganda. Unlike in commercial agriculture, where variety mixtures are known to give higher and more stable yields, the performance of cowpea variety mixtures in subsistence agriculture is little known. Mixtures containing up to four cowpea varieties were subjected to all possible 2-way, 3-way, and 4-way combinations. These cowpea varieties and mixtures were grown at three locations in Soroti and Kumi districts in order to assess the relative mixture effect, defined as: Mixture effect (% = (mixture yield − pure line component average/pure line component average × 100. Yield data was subjected to one-way ANOVA using the GLM procedure of SYSTAT. PLABSTAT was used to generate ecovalence (Wi values as a measure of stability with low ecovalence values indicating higher stability. The total cowpea dry matter (DM yield was in the range of  3.7–6.7 g/m2 (leaf and 12.1–36.7 g/m2 (grain, respectively. Mixture effects were between  −9.3–14.0% (leaf and −30.3–21.9% (grain. Yield stability spanned  Wi = 0.06–5.30 (leaf and Wi = 4.45–894.84 (grain. The results suggested that yields of cowpea variety mixtures grown in marginal environments were more stable than of single varieties but not all mixtures yielded more than single varieties.

  11. HIV testing and receipt of test results among homeless persons with serious mental illness.

    Science.gov (United States)

    Desai, Mayur M; Rosenheck, Robert A

    2004-12-01

    The purpose of this study was to determine the rates and predictors of HIV testing and receipt of results among homeless adults with serious mental illness in the initial 3-month period after contact with a community-based case management program. Baseline and follow-up interview data came from clients (N=5,890) in the Access to Community Care and Effective Services and Supports program, an 18-site, 5-year federally sponsored demonstration designed to evaluate the effect of service system integration on outcomes for homeless persons with serious mental illness. Overall, 38.0% of clients were tested for HIV in the 3 months after program entry; of these, 88.8% returned to receive their test results. Likelihood of being tested was independently associated with having been tested before, more severe psychiatric symptoms and drug problems, level of worry about getting AIDS, younger age, less education, minority status, longer-term homelessness, being sexually assaulted, being arrested, and health services utilization. Among those tested, likelihood of receiving the test results was higher among those with a history of prior testing and return for results, a higher frequency of testing, and more years of education and lower among those with drug abuse problems, outpatient medical service utilization, disability, and sexually transmitted disease. Interaction analyses showed that, for men, greater social support increased the likelihood of both HIV testing and receipt of results, while sexual victimization during follow-up decreased the likelihood that men would return for their HIV results. The majority of homeless clients enrolled in an intensive case management program were not tested for HIV during the 3-month period after program entry. Among those tested, however, nearly 90% reported receiving their results. The findings may enhance the development and targeting of strategies to increase testing and awareness of HIV serostatus among high-risk mentally ill homeless

  12. Results of gap conductance tests in the power burst facility

    International Nuclear Information System (INIS)

    Garner, R.W.; Sparks, D.T.

    1977-01-01

    Light water reactor (LWR) fuel rod behavior studies are being conducted by the Thermal Fuels Behavior Program of EG and G Idaho, Inc. These studies are being performed under contract to the Energy Research and Development Adminstration at the Idaho National Engineering Laboratory (INEL), as part of the Nuclear Regulatory Commission's Water Reactor Safety Research Fuel Behavior Program. Experimental data for verification of analytical models developed to predict light water nuclear fuel rod behavior under normal and postulated accident conditions are being obtained from a variety of in-reactor and out-of-reactor experiments. This paper summarizes the results of tests performed in the Power Burst Facility (PBF) to obtain data from which the thermal response, gap conductance, and stored energy of LWR fuel rods can be determined. Primary objectives of the PBF gap conductance test program are (a) to obtain data on a variety of pressurized water reactor (PWR) and boiling water reactor (BWR) fuel rod designs, under a wide range of operating conditions, from which gap conductance values can be determined and (b) to evaluate experimentally the power oscillation method for measuring the gap conductance and thermal response of a fresh or burned LWR fuel rod. Tests have been performed with both irradiated and unirradiated PWR-type fuel and with fresh BWR-type fuel rods. Some PWR rod test results are described, and the thermal response data from BWR rod tests are discussed in greater detail. Comparisons are made of gap conductance values determined by the tests with analytically calculated values using the Fuel Rod Analysis Program-Transient (FRAP-T) computer code. These comparisons provide insight into both the experimental measurements methods and the validity of the gap conductance models

  13. Failure to notify reportable test results: significance in medical malpractice.

    Science.gov (United States)

    Gale, Brian D; Bissett-Siegel, Dana P; Davidson, Steven J; Juran, David C

    2011-11-01

    Diagnostic physicians generally acknowledge their responsibility to notify referring clinicians whenever examinations demonstrate urgent or unexpected findings. During the past decade, clinicians have ordered dramatically greater numbers of diagnostic examinations. One study demonstrated that between 1996 and 2003, malpractice payments related to diagnosis increased by approximately 40%. Communication failures are a prominent cause of action in medical malpractice litigation. The aims of this study were to (1) define the magnitude of malpractice costs related to communication failures in test result notification and (2) determine if these costs are increasing significantly. Linear regression analysis of National Practitioner Data Bank claims data from 1991 to 2009 suggested that claims payments increased at the national level by an average of $4.7 million annually (95% confidence interval, $2.98 million to $6.37 million). Controlled Risk Insurance Company/Risk Management Foundation claims data for 2004 to 2008 indicate that communication failures played a role, accounting for 4% of cases by volume and 7% of the total cost. Faile communication of clinical data constitutes an increasing proportion of medical malpractice payments. The increase in cases may reflect expectations of more reliable notification of medical data. Another explanation may be that the remarkable growth in diagnostic test volume has led to a corresponding increase in reportable results. If notification reliability remained unchanged, this increased volume would predict more failed notifications. There is increased risk for malpractice litigation resulting from diagnostic test result notification. The advent of semiautomated critical test result management systems may improve notification reliability, improve workflow and patient safety, and, when necessary, provide legal documentation. Copyright © 2011 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  14. Large-Scale Spray Releases: Additional Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, Richard C.; Gauglitz, Phillip A.; Burns, Carolyn A.; Fountain, Matthew S.; Shimskey, Rick W.; Billing, Justin M.; Bontha, Jagannadha R.; Kurath, Dean E.; Jenks, Jeromy WJ; MacFarlan, Paul J.; Mahoney, Lenna A.

    2013-08-01

    One of the events postulated in the hazard analysis for the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak event involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids that behave as a Newtonian fluid. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and in processing facilities across the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are mostly absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale testing. The small-scale testing and resultant data are described in Mahoney et al. (2012b), and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used

  15. Overview of results from 2D airfoil testing at Risoe

    Energy Technology Data Exchange (ETDEWEB)

    Fuglsang, P. [Risoe National Lab., Wind Energy and Atmospheric Physics Dept., Roskilde (Denmark)

    1997-12-31

    This paper gives an overview of the results from two dimensional airfoil testing at Risoe. A two dimensional testing method was recently developed where a test rig is inserted into an open jet flow in a wind tunnel of the close return loop type with an open test section. Pressure measurements provide the lift and drag forces. Both stationary flow and dynamic inflow from pitch motion are possible. The wind tunnel static pressure and total dynamic pressures were calibrated and wind tunnel boundary corrections were found. So far, the testing method was verified by comparison of NACA 63-215 airfoil measurements to numerical predictions and to measurements. Furthermore, the Risoe-1, FFA-W3-241, FFA-W3-301 and NACA 63-430 airfoils were measured. Different types of leading edge roughness and vortex generators were investigated. For all airfoils, good agreements with predictions were obtained on both pressure distribution and on lift coefficient. The drag coefficients were slightly higher than predicted. (eg) 10 refs.

  16. Spent fuel drying system test results (second dry-run)

    International Nuclear Information System (INIS)

    Klinger, G.S.; Oliver, B.M.; Abrefah, J.; Marschman, S.C.; MacFarlan, P.J.; Ritter, G.A.

    1998-07-01

    The water-filled K-Basins in the Hanford 100 Area have been used to store N-Reactor spent nuclear fuel (SNF) since the 1970s. Because some leaks have been detected in the basins and some of the fuel is breached due to handling damage and corrosion, efforts are underway to remove the fuel elements from wet storage. An Integrated Process Strategy (IPS) has been developed to package, dry, transport, and store these metallic uranium fuel elements in an interim storage facility on the Hanford Site (WHC 1995). Information required to support the development of the drying processes, and the required safety analyses, is being obtained from characterization tests conducted on fuel elements removed from the K-Basins. A series of whole element drying tests (reported in separate documents, see Section 7.0) have been conducted by Pacific Northwest National Laboratory (PNNL) on several intact and damaged fuel elements recovered from both the K-East and K-West Basins. This report documents the results of the second dry-run test, which was conducted without a fuel element. With the concurrence of project management, the test protocol for this run, and subsequent drying test runs, was modified. These modifications were made to allow for improved data correlation with drying procedures proposed under the IPS. Details of these modifications are discussed in Section 3.0

  17. Stability test for amorphous materials in humidity controlled 96-well plates by near-infrared spectroscopy.

    Science.gov (United States)

    Otsuka, Makoto; Tanabe, Hideaki

    2012-03-01

    The purpose of this research is to apply near infrared spectrometry (NIR) with chemoinformetrics to predict the change of crystalline properties of indomethacin (IMC) amorphous under various levels of relative humidity storage conditions. Stability test for amorphous and meta-stable polymorphic forms was performed in humidity controlled the modified 96-well quartz plates containing various kinds of saturated salt solutions (0-100% of relative humidity (RH)) by NIR spectroscopy. Amorphous form was obtained melt product to pour into liquid nitrogen and after then ground. Samples were stored at 25°C in the 6-well plates at various levels of RH. The spectra of the powder samples were measured by the reflectance FT-NIR spectrometer. The second derivative spectra of form α showed specific absorption peaks at 4980, 6036, 7296 and 8616 cm-1 and that of form γ showed those at 5020, 5028, 7344, 7428 and 8436 cm-1. After storage at less than 50% RH, the peak intensities at 5020, 5028, 7344, 7428 and 8436 cm-1 of the amorphous solid increased with increasing of storage time. However, the peak intensity at 4980, 6036 and 7296 cm-1 increased at more than 50% RH Please check and confirm the edit. The results suggested that at lower humidity, the IMC amorphous solid transformed into form γ, but it transformed into form α at more than high humidity. It is possible that crystalline stability of the pharmaceutical preparations could be predicted by using humidity controlled 96-well plates and reflectance NIR-chemoinformetric methods.

  18. Production Facility Prototype Blower 1000 Hour Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Woloshun, Keith Albert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dale, Gregory E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Frank Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dalmas, Dale Allen [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-10-18

    The roots blower in use at ANL for in-beam experiments and also at LANL for flow tests was sized for 12 mm diameter disks and significantly less beam heating. Currently, the disks are 29 mm in diameter, with a 12 mm FWHM Gaussian beam spot at 42 MeV and 2.86 μA on each side of the target, 5.72 μA total. The target design itself is reported elsewhere. With the increased beam heating, the helium flow requirement increased so that a larger blower was needed for a mass flow rate of 400 g/s at 2.76 MPa (400 psig). An Aerzen GM 12.4 blower was selected, and is now installed at the LANL facility for target and component flow testing. Two extended tests of >1000 hr operation have been completed. Those results and discussion thereof are reported herein. Also included in Appendix A is the detailed description of the blower and its installation, while Appendix B documents the pressure vessel design analysis. The blower has been operated for 1000 hours as a preliminary investigation of long-term performance, operation and possible maintenance issues. The blower performed well, with no significant change in blower head or mass flow rate developed under the operating conditions. Upon inspection, some oil had leaked out of the shaft seal of the blower. The shaft seal and bearing race have been replaced. Test results and conclusions are in Appendix B.

  19. Test Results for the Automated Rendezvous and Capture System

    Science.gov (United States)

    Cruzen, Craig; Dabney, Richard; Lomas, James

    1999-01-01

    The Automated Rendezvous and Capture (AR&C) system was designed and tested at NASA's Marshall Space Flight Center (MSFC) to demonstrate technologies and mission strategies for automated rendezvous and docking of spacecraft in Earth orbit, The system incorporates some of the latest innovations in Global Positioning, System space navigation, laser sensor technologies and automated mission sequencing algorithms. The system's initial design and integration was completed in 1998 and has undergone testing at MSFC. This paper describes the major components of the AR&C system and presents results from the official system tests performed in MSFC's Flight Robotics Laboratory with digital simulations and hardware in the loop tests. The results show that the AR&C system can safely and reliably perform automated rendezvous and docking missions in the absence of system failures with 100 percent success. When system failures are included, the system uses its automated collision avoidance maneuver logic to recover in a safe manner. The primary objective of the AR&C project is to prove that by designing a safe and robust automated system, mission operations cost can be reduced by decreasing the personnel required for mission design, preflight planning and training required for crewed rendezvous and docking missions.

  20. Honeywell Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Sargusingh, Miriam

    2014-01-01

    The ability to recover and purify water through physiochemical processes is crucial for realizing long-term human space missions, including both planetary habitation and space travel. Because of their robust nature, distillation systems have been actively pursued as one of the technologies for water recovery. The Cascade Distillation System (CDS) is a vacuum rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. The CDS was previously under development through Honeywell and NASA. In 2009, an assessment was performed to collect data to support down-selection and development of a primary distillation technology for application in a lunar outpost water recovery system. Based on the results of this testing, an expert panel concluded that the CDS showed adequate development maturity, TRL-4, together with the best product water quality and competitive weight and power estimates to warrant further development. The Advanced Exploration Systems (AES) Water Recovery Project (WRP) worked to address weaknesses identified by The Panel; namely bearing design and heat pump power efficiency. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades. The CDS will also have been challenged with ISS analog waste streams and a subset of those being considered for Exploration architectures. This paper details interim results of the AES WRP CDS performance testing.

  1. Seismic II over I Drop Test Program results and interpretation

    International Nuclear Information System (INIS)

    Thomas, B.

    1993-03-01

    The consequences of non-seismically qualified (Category 2) objects falling and striking essential seismically qualified (Category 1) objects has always been a significant, yet analytically difficult problem, particularly in evaluating the potential damage to equipment that may result from earthquakes. Analytical solutions for impact problems are conservative and available for mostly simple configurations. In a nuclear facility, the open-quotes sourcesclose quotes and open-quotes targetsclose quotes requiring evaluation are frequently irregular in shape and configuration, making calculations and computer modeling difficult. Few industry or regulatory rules are available on this topic even though it is a source of considerable construction upgrade costs. A drop test program was recently conducted to develop a more accurate understanding of the consequences of seismic interactions. The resulting data can be used as a means to improve the judgment of seismic qualification engineers performing interaction evaluations and to develop realistic design criteria for seismic interactions. Impact tests on various combinations of sources and targets commonly found in one Savannah River Site (SRS) nuclear facility were performed by dropping the sources from various heights onto the targets. This report summarizes results of the Drop Test Program. Force and acceleration time history data are presented as well as general observations on the overall ruggedness of various targets when subjected to impacts from different types of sources

  2. SALT segmented primary mirror: laboratory test results for FOGALE inductive edge sensors

    Science.gov (United States)

    Menzies, John; Gajjar, Hitesh; Buous, Sébastien; Buckley, David; Gillingham, Peter

    2010-07-01

    At the Southern African Large Telescope (SALT), in collaboration with FOGALE Nanotech, we have been testing the recently-developed new generation inductive edge sensors. The Fogale inductive sensor is one technology being evaluated as a possible replacement for the now defunct capacitance-based edge sensing system. We present the results of exhaustive environmental testing of two variants of the inductive sensor. In addition to the environmental testing including RH and temperature cycles, the sensor was tested for sensitivity to dust and metals. We also consider long-term sensor stability, as well as that of the electronics and of the glue used to bond the sensor to its supporting structure. A prototype design for an adjustable mount is presented which will allow for in-plane gap and shear variations present in the primary mirror configuration without adversely disturbing the figure of the individual mirror segments or the measurement accuracy.

  3. Stability of fruit quality traits in diverse watermelon cultivars tested in multiple environments

    Science.gov (United States)

    Dia, Mahendra; Wehner, Todd C; Perkins-Veazie, Penelope; Hassell, Richard; Price, Daniel S; Boyhan, George E; Olson, Stephen M; King, Stephen R; Davis, Angela R; Tolla, Gregory E; Bernier, Jerome; Juarez, Benito

    2016-01-01

    Lycopene is a naturally occurring red carotenoid compound that is found in watermelon. Lycopene has antioxidant properties. Lycopene content, sugar content and hollowheart resistance are subject to significant genotype×environment interaction (G×E), which makes breeding for these fruit quality traits difficult. The objectives of this study were to (i) evaluate the influence of years and locations on lycopene content, sugar content and hollowheart resistance for a set of watermelon genotypes, and (ii) identify genotypes with high stability for lycopene, sugar, and hollowheart resistance. A diverse set of 40 genotypes was tested over 3 years and 8 locations across the southern United States in replicated, multi-harvest trials. Lycopene was tested in a subset of 10 genotypes. Data were analyzed using univariate and multivariate stability statistics (BLUP-GGE biplot) using SASGxE and RGxE programs. There were strong effects of environment as well as G×E interaction on watermelon quality traits. On the basis of stability measures, genotypes were classified as stable or unstable for each quality trait. 'Crimson Sweet' is an inbred line with high quality trait performance as well as trait stability. 'Stone Mountain', 'Tom Watson', 'Crimson Sweet' and 'Minilee' were among the best genotypes for lycopene content, sugar content and hollowheart resistance. We developed a stability chart based on marketable yield and average ranking generated from different stability measures for yield attributes and quality traits. The chart will assist in choosing parents for improvement of watermelon cultivars. See http://cuke.hort.ncsu.edu/cucurbit/wmelon/wmelonmain.html. PMID:28066557

  4. Comparison of road load simulator test results with track tests on electric vehicle propulsion system

    Science.gov (United States)

    Dustin, M. O.

    1983-01-01

    A special-purpose dynamometer, the road load simulator (RLS), is being used at NASA's Lewis Research Center to test and evaluate electric vehicle propulsion systems developed under DOE's Electric and Hybrid Vehicle Program. To improve correlation between system tests on the RLS and track tests, similar tests were conducted on the same propulsion system on the RLS and on a test track. These tests are compared in this report. Battery current to maintain a constant vehicle speed with a fixed throttle was used for the comparison. Scatter in the data was greater in the track test results. This is attributable to variations in tire rolling resistance and wind effects in the track data. It also appeared that the RLS road load, determined by coastdown tests on the track, was lower than that of the vehicle on the track. These differences may be due to differences in tire temperature.

  5. Small-Scale Spray Releases: Additional Aerosol Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Schonewill, Philip P.; Gauglitz, Phillip A.; Kimura, Marcia L.; Brown, G. N.; Mahoney, Lenna A.; Tran, Diana N.; Burns, Carolyn A.; Kurath, Dean E.

    2013-08-01

    One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are largely absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale. The small-scale testing and resultant data are described in Mahoney et al. (2012b) and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used to mimic the

  6. The first operation of the Delphos plant: Test results

    International Nuclear Information System (INIS)

    Sarno, A.; Noviello, G.; Cordisco, S.; Di Paola, L.; Guerra, M.

    1991-09-01

    The data collected during the O and M of the Delphos plant and the testing results are presented and discussed. Together with the maintenance influence on the operation and production of the plant, the various downtime causes are pointed out. An extensive activity has been carried out to investigate the actual behaviour of the photovoltaic generator and the power conditioning unit. The analysis of the experimental results allows to focus on the different causes of loss and suggest some actions to be taken in order to improve the plant efficiency and increase the energy production. (author)

  7. True Stability of Lubricants Determined Using the Ball-on-Disk Test

    Directory of Open Access Journals (Sweden)

    Angela Maria Tortora

    2016-01-01

    Full Text Available True stability of lubricants can be determined when there is minimum change in the contact area and also the intervention of wear debris in the contact zone. Here, we have used the ball-on-disk instrument with the migrating point contact, that is, relative motion between the ball and disk condition to fix the contact area and minimize the wear debris at the contact zone. The jump in the friction coefficient indicates the film failure, which appeared earlier for the motor oil 5W30 compared to 5W40. Such profile was not recorded in absence of relative motion. Therefore, 5W40 was considered to have a better lubricant stability than 5W30. Applying the same test condition to the natural lubricants shows that glycerol has better lubricant stability than glycerol-water mixture. Superior true lubricant stability by glycerol and 5W40 can be related to its high viscosity. However, they were less wear resistant compared to low viscosity lubricants like 5W30 and glycerol-water. We suspect the role of microscopic wear debris at the contact zone for this behavior although it should have been avoided in the migrating point contact condition. Overall, ball-on-disk instrument with a migrating point contact condition is an effective technique to determine the stability of lubricants.

  8. DEVELOPING THE STABILIZED MAPPING SYSTEM FOR THE GYROCOPTER – REPORT FROM THE FIRST TESTS

    Directory of Open Access Journals (Sweden)

    J. Kolecki

    2016-06-01

    Full Text Available The LiDAR mapping carried out using gyrocopters provides a relatively cheap alternative for traditional mapping involving airplanes. The costs of the fuel and the overall maintenance are much lower when compared to planes. At the same time the flight kinematics of the gyrocopter makes it an ideal vehicle for corridor mapping. However a limited payload and a strongly limited space prevent using stabilized platforms dedicated for aerial photogrammetry. As the proper stabilization of the laser scanner during the flight is crucial in order to keep the desirable quality of the LiDAR data, it was decided to develop the prototype of the stabilized, ultra-light mapping platform that can meet the restricted requirements of the gyrocopter. The paper starts with the brief discussion of the legal and practical aspects of the LiDAR data quality, dealing mostly with the influence of the flight imperfections on the point pattern and point density. Afterwards the mapping system prototype is characterized, taking into account three main components: stabilized platform, sensors and control. Subsequently first in-flight tests are described. Though the data are still not perfect mostly due to vibrations, the stabilization provides a substantial improvement of their geometry, reducing both roll and pitch deflections.

  9. Aerodynamic and Acoustic Flight Test Results for the Stratospheric Observatory for Infrared Astronomy

    Science.gov (United States)

    Cumming, Stephen B.; Cliatt, Larry James; Frederick, Michael A.; Smith, Mark S.

    2013-01-01

    As part of the Stratospheric Observatory for Infrared Astronomy (SOFIA) program, a 747SP airplane was modified to carry a 2.5 meter telescope in the aft section of the fuselage. The resulting airborne observatory allows for observations above 99 percent of the water vapor in the atmosphere. The open cavity created by the modifications had the potential to significantly affect the airplane in the areas of aerodynamics and acoustics. Several series of flight tests were conducted to clear the airplanes operating envelope for astronomical observations, planned to be performed between the altitudes of 39,000 feet and 45,000 feet. The flight tests were successfully completed. Cavity acoustics were below design limits, and the overall acoustic characteristics of the cavity were better than expected. The modification did have some effects on the stability and control of the airplane, but these effects were not significant. Airplane air data systems were not affected by the modifications. This paper describes the methods used to examine the aerodynamics and acoustic data from the flight tests and provides a discussion of the flight test results in the areas of cavity acoustics, stability and control, and air data.

  10. Comparative test results for two ODE solvers: EPISODE and GEAR

    Energy Technology Data Exchange (ETDEWEB)

    Byrne, G.D.; Hindmarsh, A.C.; Jackson, K.R.; Brown, H.G.

    1977-03-01

    This is a sequel to the paper ''A comparison of two ODE codes: GEAR and EPISODE,'' and is concerned with the testing of two superficially similar ODE packages, GEAR and EPISODE. Fourteen basic test problems, some with several cases, are the basis for the testing. These problems represent several types--nonlinear systems with real and complex eigenvalues, linear systems with varied diagonal dominance, linear scalar problems, stiff and nonstiff problems, chemical kinetics with and without diurnal effect, and systems arising from the use of the numerical method of lines. Some problems are included in order to examine the options and error returns. The test results are presented in two forms: raw output and a comparative display of operation counts and of timings for the best method in the GEAR package and the best method in the EPISODE package. This approach allows a comparison of the consequences of the fixed-step interpolate strategy (GEAR) for changing step size against the truly variable step size strategy (EPISODE). It is concluded that EPISODE is generally faster than GEAR for problems involving wave fronts or transients on the interior of the interval of integration. For linear or simply decaying problems, these roles are usually reversed. 19 figures, 116 tables.

  11. Automation and results of Adjacent Band Emission testing

    Science.gov (United States)

    2015-03-01

    Problem Statement : Multiple groups conduct tests in various ways - Outcomes vary based on test setup and assumptions - No standard has been established to conduct such tests - Spectrum is scarce and the need for compliance testing will only increase...

  12. Multiple sample setup for testing the hydrothermal stability of adsorbents in thermal energy storage applications

    International Nuclear Information System (INIS)

    Fischer, Fabian; Laevemann, Eberhard

    2015-01-01

    Thermal energy storage based on adsorption and desorption of water on an adsorbent can achieve high energy storage densities. Many adsorbents lose adsorption capacity when operated under unfavourable hydrothermal conditions during adsorption and desorption. The stability of an adsorbent against stressing hydrothermal conditions is a key issue for its usability in adsorption thermal energy storage. We built an experimental setup that simultaneously controls the hydrothermal conditions of 16 samples arranged in a matrix of four temperatures and four water vapour pressures. This setup allows the testing of potential adsorbents between temperatures of 50 °C and 350 °C and water vapour pressures of up to 32 kPa. A measurement procedure that allows the detection of the hydrothermal stability of an adsorbent after defined time spans has been designed. We verified the functionality of the multiple sample measurements with a microporous adsorbent, a zeolite NaMSX. The hydrothermal stability of this zeolite is tested by water uptake measurements. A standard deviation lower than 1% of the 16 samples for detecting the hydrothermal stability enables setting different conditions in each sample cell. Further, we compared the water uptake measurements by measuring their adsorption isotherms with the volumetric device BELSORP Aqua 3 from Bel Japan. (paper)

  13. Functional Fitness Testing Results Following Long-Duration ISS Missions.

    Science.gov (United States)

    Laughlin, Mitzi S; Guilliams, Mark E; Nieschwitz, Bruce A; Hoellen, David

    2015-12-01

    Long-duration spaceflight missions lead to the loss of muscle strength and endurance. Significant reduction in muscle function can be hazardous when returning from spaceflight. To document these losses, NASA developed medical requirements that include measures of functional strength and endurance. Results from this Functional Fitness Test (FFT) battery are also used to evaluate the effectiveness of in-flight exercise countermeasures. The purpose of this paper is to document results from the FFT and correlate this information with performance of in-flight exercise on board the International Space Station. The FFT evaluates muscular strength and endurance, flexibility, and agility and includes the following eight measures: sit and reach, cone agility, push-ups, pull-ups, sliding crunches, bench press, leg press, and hand grip dynamometry. Pre- to postflight functional fitness measurements were analyzed using dependent t-tests and correlation analyses were used to evaluate the relationship between functional fitness measurements and in-flight exercise workouts. Significant differences were noted post space flight with the sit and reach, cone agility, leg press, and hand grip measurements while other test scores were not significantly altered. The relationships between functional fitness and in-flight exercise measurements showed minimal to moderate correlations for most in-flight exercise training variables. The change in FFT results can be partially explained by in-flight exercise performance. Although there are losses documented in the FFT results, it is important to realize that the crewmembers are successfully performing activities of daily living and are considered functional for normal activities upon return to Earth.

  14. Results of field testing of waste forms using lysimeters

    International Nuclear Information System (INIS)

    McConnell, J.W. Jr.; Rogers, R.D.

    1990-01-01

    The TMI-2 [Three Mile Island Unit 2] EPICOR-II Resin/Liner Low-Level Waste Data Base Development Program, funded by the U.S. Nuclear Regulatory Commission (NRC), is obtaining information on the performance of radioactive waste in a disposal environment. Waste forms fabricated using ion-exchange resins from EPICOR-II prefilters employed in the cleanup of the Three Mile Island Nuclear Power Station are being tested to: (a) develop a low-level waste data base, and (b) obtain information on survivability of waste forms in a disposal environment. This paper updates field testing of those waste forms during FY-1989. The results of the lysimeters is presented and the use of lysimeter data in performance assessment is discussed. 16 refs., 10 figs., 5 tabs

  15. LEDA RF distribution system design and component test results

    International Nuclear Information System (INIS)

    Roybal, W.T.; Rees, D.E.; Borchert, H.L.; McCarthy, M.; Toole, L.

    1998-01-01

    The 350 MHz and 700 MHz RF distribution systems for the Low Energy Demonstration Accelerator (LEDA) have been designed and are currently being installed at Los Alamos National Laboratory. Since 350 MHz is a familiar frequency used at other accelerator facilities, most of the major high-power components were available. The 700 MHz, 1.0 MW, CW RF delivery system designed for LEDA is a new development. Therefore, high-power circulators, waterloads, phase shifters, switches, and harmonic filters had to be designed and built for this applications. The final Accelerator Production of Tritium (APT) RF distribution systems design will be based on much of the same technology as the LEDA systems and will have many of the RF components tested for LEDA incorporated into the design. Low power and high-power tests performed on various components of these LEDA systems and their results are presented here

  16. Using Large Scale Test Results for Pedagogical Purposes

    DEFF Research Database (Denmark)

    Dolin, Jens

    2012-01-01

    , and the teachers’ and students’ use of this information for pedagogical purposes in the classroom. We know well how the policy makers interpret and use the outcomes of such tests, but we know less about how teachers make use of LSTs to inform their pedagogical practice. An important question is whether...... there is a contradiction between the political system’s use of LST and teachers’ (possible) pedagogical use of LST. And if yes: What is a contradiction based on? This presentation will give some results from a systematic review on how tests have influenced the pedagogical practice. The research revealed many of the fatal...... system and the different theoretical foundations of PISA and most teachers’ pedagogically oriented, formative assessment, thus explaining the teacher resentment towards LSTs. Finally, some principles for linking LSTs to teachers’ pedagogical practice will be presented....

  17. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Maerker, R.E.; Stallmann, F.W.

    1984-01-01

    The metallurgical irradiation experiment at the Oak Ridge Research Reactor Poolside Facility (ORR-PSF) was designed as a benchmark to test the accuracy of radiation embrittlement predictions in the pressure vessel wall of light water reactors on the basis of results from surveillance capsules. The PSF metallurgical Blind Test is concerned with the simulated surveillance capsule (SSC) and the simulated pressure vessel capsule (SPVC). The data from the ORR-PSF benchmark experiment are the basis for comparison with the predictions made by participants of the metallurgical ''Blind Test''. The Blind Test required the participants to predict the embrittlement of the irradiated specimen based only on dosimetry and metallurgical data from the SSC1 capsule. This exercise included both the prediction of damage fluence and the prediction of embrittlement based on the predicted fluence. A variety of prediction methodologies was used by the participants. No glaring biases or other deficiencies were found, but neither were any of the methods clearly superior to the others. Closer analysis shows a rather complex and poorly understood relation between fluence and material damage. Many prediction formulas can give an adequate approximation, but further improvement of the prediction methodology is unlikely at this time given the many unknown factors. Instead, attention should be focused on determining realistic uncertainties for the predicted material changes. The Blind Test comparisons provide some clues for the size of these uncertainties. In particular, higher uncertainties must be assigned to materials whose chemical composition lies outside the data set for which the prediction formula was obtained. 16 references, 14 figures, 5 tables

  18. Hot-Fire Test Results of Liquid Oxygen/RP-2 Multi-Element Oxidizer-Rich Preburners

    Science.gov (United States)

    Protz, C. S.; Garcia, C. P.; Casiano, M. J.; Parton, J. A.; Hulka, J. R.

    2016-01-01

    As part of the Combustion Stability Tool Development project funded by the Air Force Space and Missile Systems Center, the NASA Marshall Space Flight Center was contracted to assemble and hot-fire test a multi-element integrated test article demonstrating combustion characteristics of an oxygen/hydrocarbon propellant oxidizer-rich staged-combustion engine thrust chamber. Such a test article simulates flow through the main injectors of oxygen/kerosene oxidizer-rich staged combustion engines such as the Russian RD-180 or NK-33 engines, or future U.S.-built engine systems such as the Aerojet-Rocketdyne AR-1 engine or the Hydrocarbon Boost program demonstration engine. To supply the oxidizer-rich combustion products to the main injector of the integrated test article, existing subscale preburner injectors from a previous NASA-funded oxidizer-rich staged combustion engine development program were utilized. For the integrated test article, existing and newly designed and fabricated inter-connecting hot gas duct hardware were used to supply the oxidizer-rich combustion products to the oxidizer circuit of the main injector of the thrust chamber. However, before one of the preburners was used in the integrated test article, it was first hot-fire tested at length to prove it could provide the hot exhaust gas mean temperature, thermal uniformity and combustion stability necessary to perform in the integrated test article experiment. This paper presents results from hot-fire testing of several preburner injectors in a representative combustion chamber with a sonic throat. Hydraulic, combustion performance, exhaust gas thermal uniformity, and combustion stability data are presented. Results from combustion stability modeling of these test results are described in a companion paper at this JANNAF conference, while hot-fire test results of the preburner injector in the integrated test article are described in another companion paper.

  19. Improved result on stability analysis of discrete stochastic neural networks with time delay

    International Nuclear Information System (INIS)

    Wu Zhengguang; Su Hongye; Chu Jian; Zhou Wuneng

    2009-01-01

    This Letter investigates the problem of exponential stability for discrete stochastic time-delay neural networks. By defining a novel Lyapunov functional, an improved delay-dependent exponential stability criterion is established in terms of linear matrix inequality (LMI) approach. Meanwhile, the computational complexity of the newly established stability condition is reduced because less variables are involved. Numerical example is given to illustrate the effectiveness and the benefits of the proposed method.

  20. The Castor 120 (TM) motor: Development and qualification testing results

    Science.gov (United States)

    Hilden, Jack G.; Poirer, Beverly M.

    1993-01-01

    This paper discusses Thiokol Corporation's static test results for the development and qualification program of the Castor 120(TM) motor. The demonstration program began with a 25,000-pound motor to demonstrate the new technologies and processes that would be used on the larger Castor 120(TM) motor. The Castor 120(TM) motor was designed to be applicable as a first stage, second stage, or strap-on motor. Static test results from the Castor 25 and two Castor 120(TM) motors are discussed in this paper. The results verified the feasibility of tailoring the propellant grain configuration and nozzle throat diameter to meet various customer requirements. The first and second motors were conditioned successfully at ambient temperature and 28 F, respectively, to demonstrate that the design could handle a wide range of environmental launch conditions. Furthermore, the second Castor 120(TM) motor demonstrated a systems tunnel and forward skirt extension to verify flight-ready stage hardware. It is anticipated that the first flight motor will be ready by the fall of 1994.

  1. Expose : procedure and results of the joint experiment verification tests

    Science.gov (United States)

    Panitz, C.; Rettberg, P.; Horneck, G.; Rabbow, E.; Baglioni, P.

    The International Space Station will carry the EXPOSE facility accommodated at the universal workplace URM-D located outside the Russian Service Module. The launch will be affected in 2005 and it is planned to stay in space for 1.5 years. The tray like structure will accomodate 2 chemical and 6 biological PI-experiments or experiment systems of the ROSE (Response of Organisms to Space Environment) consortium. EXPOSE will support long-term in situ studies of microbes in artificial meteorites, as well as of microbial communities from special ecological niches, such as endolithic and evaporitic ecosystems. The either vented or sealed experiment pockets will be covered by an optical filter system to control intensity and spectral range of solar UV irradiation. Control of sun exposure will be achieved by the use of individual shutters. To test the compatibility of the different biological systems and their adaptation to the opportunities and constraints of space conditions a profound ground support program has been developed. The procedure and first results of this joint Experiment Verification Tests (EVT) will be presented. The results will be essential for the success of the EXPOSE mission and have been done in parallel with the development and construction of the final hardware design of the facility. The results of the mission will contribute to the understanding of the organic chemistry processes in space, the biological adaptation strategies to extreme conditions, e.g. on early Earth and Mars, and the distribution of life beyond its planet of origin.

  2. THE LT-CFB GASIFIER – FIRST TEST RESULTS FROM THE 500 KW TEST PLANT

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Glar; Stoholm, Peder; Nielsen, Mads Brix

    2005-01-01

    The Low Temperature Circulating Fluidised Bed (LT-CFB) gasification process is briefly described together with the first test results from the new 500 kW test plant. The process aims primarily at co-firing low grade biomass and waste products at power plants and offer several advantages to direct...

  3. New STS-1 Electronics: Development and Test Results

    Science.gov (United States)

    Uhrhammer, R. A.; Karavas, B.; Friday, J.; Vanzandt, T.; Hutt, C. R.; Wielandt, E.; Romanowicz, B.

    2007-12-01

    refinements, this generation of electronics was operated on two seismometers concurrently and successfully run through swept sine and step calibration functions on four seismometers. During this final phase, the Metrozet electronics included the ability to initiate and operate the calibrations via a network (Ethernet) connection. Most of the calibration testing was performed remotely from Metrozet's Southern California office over the BSL network. Metrozet was able to remotely log into the Berkeley network, establish a connection to the test bed in the Byerly seismic vault and initiate control of the seismometer including remote centering and calibration functions. Finally, after BSL tests were completed and the development appeared complete and satisfactory, the new electronics were tested at the Albuquerque Seismological Laboratory's seismic vault, which is located in a quieter environment than BKS. The new electronics package was also field tested at the BDSN broadband station HOPS. We present detailed results of the calibrations.

  4. Advanced stellar compass deep space navigation, ground testing results

    DEFF Research Database (Denmark)

    Betto, Maurizio; Jørgensen, John Leif; Jørgensen, Peter Siegbjørn

    2006-01-01

    . Nevertheless, up to now, ground navigation has been the only possible solution. The technological breakthrough of advanced star trackers, like the micro-advanced stellar compass (mu ASC) might change this situation. Indeed, exploiting the capabilities of this instrument, the authors have devised a method...... to determine the orbit of a spacecraft autonomously, on-board and without any a priori knowledge of any kind. The solution is robust, elegant and fast. This paper presents the preliminary performances obtained during the ground tests. The results are very positive and encouraging....

  5. Assessing Equivalent Viscous Damping Using Piping System test Results

    Energy Technology Data Exchange (ETDEWEB)

    Nie, J.; Morante, R.

    2010-07-18

    The specification of damping for nuclear piping systems subject to seismic-induced motions has been the subject of many studies and much controversy. Damping estimation based on test data can be influenced by numerous factors, consequently leading to considerable scatter in damping estimates in the literature. At present, nuclear industry recommendations and nuclear regulatory guidance are not consistent on the treatment of damping for analysis of nuclear piping systems. Therefore, there is still a need to develop a more complete and consistent technical basis for specification of appropriate damping values for use in design and analysis. This paper summarizes the results of recent damping studies conducted at Brookhaven National Laboratory.

  6. The space telescope NINA: results of a beam test calibration

    CERN Document Server

    Bidoli, V; Pascale, M P D; Morselli, A; Furano, G; Picozza, P; Scoscini, A; Sparvoli, R; Barbiellini, G; Bonvicini, W; Cirami, R; Schiavon, Paolo; Vacchi, A; Zampa, N; Ambriola, M; Bellotti, R; Cafagna, F; Ciacio, F; Castellano, M; Circella, M; Marzo, C D; Bartalucci, S; Giuntoli, S; Ricci, M; Papini, P; Piccardi, S; Spillantini, P; Bakaldin, A; Batishev, A; Galper, A M; Koldashov, S; Korotkov, M; Mikhailov, V; Murashov, A; Voronov, S; Boezio, M

    1999-01-01

    In June 1998 the telescope NINA will be launched in space on board of the Russian satellite Resource-01 n.4. The main scientific objective of the mission is the study of the anomalous, galactic and solar components of the cosmic rays in the energy interval 10-200 MeV/n. The core of the instrument is a silicon detector whose performances have been tested with a particle beam at the GSI Laboratory in Germany in 1997; we report here on the results obtained during the beam calibration.

  7. Hanford coring bit temperature monitor development testing results report

    International Nuclear Information System (INIS)

    Rey, D.

    1995-05-01

    Instrumentation which directly monitors the temperature of a coring bit used to retrieve core samples of high level nuclear waste stored in tanks at Hanford was developed at Sandia National Laboratories. Monitoring the temperature of the coring bit is desired to enhance the safety of the coring operations. A unique application of mature technologies was used to accomplish the measurement. This report documents the results of development testing performed at Sandia to assure the instrumentation will withstand the severe environments present in the waste tanks

  8. Plutonium immobilization program - Cold pour Phase 1 test results

    International Nuclear Information System (INIS)

    Hamilton, L.

    2000-01-01

    The Plutonium Immobilization Project will disposition excess weapons grade plutonium. It uses the can-in-canister approach that involves placing plutonium-ceramic pucks in sealed cans that are then placed into Defense Waste Processing Facility canisters. These canisters are subsequently filled with high-level radioactive waste glass. This process puts the plutonium in a stable form and makes it unattractive for reuse. A cold (non-radioactive) glass pour program was performed to develop and verify the baseline design for the canister and internal hardware. This paper describes the Phase 1 scoping test results

  9. Plutonium Immobilization Program - Cold pour Phase 1 test results

    International Nuclear Information System (INIS)

    Hamilton, L.

    2000-01-01

    The Plutonium Immobilization Project will disposition excess weapons grade plutonium. It uses the can-in-canister approach that involves placing plutonium-ceramic pucks in sealed cans that are then placed into Defense Waste Processing Facility canisters. These canisters are subsequently filled with high-level radioactive waste glass. This process puts the plutonium in a stable form and makes it unattractive for reuse. A cold (non-radioactive) glass pour program was performed to develop and verify the baseline design for the canister and internal hardware. This paper describes the Phase 1 scoping test results

  10. Bridge Testing With Ground-Based Interferometric Radar: Experimental Results

    Science.gov (United States)

    Chiara, P.; Morelli, A.

    2010-05-01

    The research of innovative non-contact techniques aimed at the vibration measurement of civil engineering structures (also for damage detection and structural health monitoring) is continuously directed to the optimization of measures and methods. Ground-Based Radar Interferometry (GBRI) represents the more recent technique available for static and dynamic control of structures and ground movements. Dynamic testing of bridges and buildings in operational conditions are currently performed: (a) to assess the conformity of the structure to the project design at the end of construction; (b) to identify the modal parameters (i.e. natural frequencies, mode shapes and damping ratios) and to check the variation of any modal parameters over the years; (c) to evaluate the amplitude of the structural response to special load conditions (i.e. strong winds, earthquakes, heavy railway or roadway loads). If such tests are carried out by using a non-contact technique (like GBRI), the classical issues of contact sensors (like accelerometers) are easily overtaken. This paper presents and discusses the results of various tests carried out on full-scale bridges by using a Stepped Frequency-Continuous Wave radar system.

  11. Test Results for LHC Insertion Region Dipole Magnets

    CERN Document Server

    Muratore, Joseph F; Cozzolino, John P; Ganetis, George; Ghosh, Arup; Gupta, Ramesh C; Harrison, Michael; Kumar-Jain, Animesh; Marone, Andrew; Richard-Plate, Stephen; Schmalzle, Jesse D; Thomas, Richard A; Wanderer, Peter; Willen, Erich; Wu, Kuo-Chen

    2005-01-01

    The Superconducting Magnet Division at Brookhaven National Laboratory (BNL) has made 20 insertion region dipoles for the Large Hadron Collider (LHC) at CERN. These 9.45 m-long, 8 cm aperture magnets have the same coil design as the arc dipoles now operating in the Relativistic Heavy Ion Collider (RHIC) at BNL and are of single aperture, twin aperture, and double cold mass configurations. They produce fields up to 3.8 T for operation at 7.56 TeV. Eighteen of these magnets have been tested at 4.5 K using either forced flow supercritical helium or liquid helium. The testing was especially important for the twin aperture models, which have the most challenging design. In these, the dipole fields in both apertures point in the same direction, unlike LHC arc dipoles. This paper reports on the results of these tests, including spontaneous quench performance, verification of quench protection heater operation, and magnetic field quality. Magnetic field measurements were done at 4.5K and at room temperature, and warm-...

  12. Pathfinder Technology Demonstrator: GlobalStar Testing and Results

    Science.gov (United States)

    Kuroda, Vanessa; Limes, Gregory L.; Han, Shi Lei; Hanson, John Eric; Christa, Scott E.

    2016-01-01

    The communications subsystem of a spacecraft is typically a SWaP (size, weight, and power) intensive subsystem in a SWaP constrained environment such as a CubeSat. Use of a satellite-based communication system, such as GlobalStars duplex GSP-1720 radio is a low SWaP potentially game-changing low-cost communication subsystem solution that was evaluated for feasibility for the NASA Pathfinder Technology Demonstrator (PTD) project. The PTD project is a series of 6U CubeSat missions to flight demonstrate and characterize novel small satellite payloads in low Earth orbit. GlobalStar is a low Earth orbit satellite constellation for satellite phone and low-speed data communications, and the GSP-1720 is their single board duplex radio most commonly used in satellite phones and shipment tracking devices. The PTD project tested the GSP-1720 to characterize its viability for flight using NASA GEVS (General Environmental Verification Standard) vibration and thermal vacuum levels, as well as testing the uplink-downlink connectivity, data throughput, and file transfer capabilities. This presentation will present the results of the environmental and capability testing of the GSP-1720 performed at NASA Ames Research Center, as well as the viability for CubeSat use in LEO.

  13. Results of Ageing Tests on the Forward MSGC 'BANANA' Prototype

    CERN Document Server

    Boimska, B; Capéans-Garrido, M; Claes, S; Hoch, Michael; Million, Gilbert; Ropelewski, Leszek; Sharma, Abhishek; Shekhtman, L I; Van Doninck, Walter; Van Lancker, Luc

    1996-01-01

    The forward tracker of the CMS experiment at CERN will consist of a large number of MicroStrip Gas Chambers ( MSGCs), expected to operate for several years in the high luminosity environment of LHC with an accumulated dose rate of ~ 10 mC/yr per cm of strip. They are planned to be arranged around the interaction point in modular wheels which contain several MSGCs. The 'open'option of a forward CMS 'banana' module includes the electronics inside the gas volume. Long term tests of one such prototype containing two plates, one with gold and the other with chromium strips on diamond-like coated D263 glass with representative electronics and surface mount components inside the gas volume have been performed; the satisfactory results are reported here. A first test has been made with a gas flow rate of 60 cc/min in the prototype ( corresponding to 5 gas renewals per hour) and has shown no gain drop up to 85 mC/cm of accumulated charge per strip. A second test has been performed with a gas flow rate of 6 cc/min corr...

  14. Results from Field Testing the RIMFAX GPR on Svalbard.

    Science.gov (United States)

    Hamran, S. E.; Amundsen, H. E. F.; Berger, T.; Carter, L. M.; Dypvik, H.; Ghent, R. R.; Kohler, J.; Mellon, M. T.; Nunes, D. C.; Paige, D. A.; Plettemeier, D.; Russell, P.

    2017-12-01

    The Radar Imager for Mars' Subsurface Experiment - RIMFAX is a Ground Penetrating Radar being developed for NASÁs MARS 2020 rover mission. The principal goals of the RIMFAX investigation are to image subsurface structures, provide context for sample sites, derive information regarding subsurface composition, and search for ice or brines. In meeting these goals, RIMFAX will provide a view of the stratigraphic section and a window into the geological and environmental history of Mars. To verify the design an Engineering Model (EM) of the radar was tested in the field in the spring 2017. Different sounding modes on the EM were tested in different types of subsurface geology on Svalbard. Deep soundings were performed on polythermal glaciers down to a couple of hundred meters. Shallow soundings were used to map a ground water table in the firn area of a glacier. A combination of deep and shallow soundings was used to image buried ice under a sedimentary layer of a couple of meters. Subsurface sedimentary layers were imaged down to more than 20 meters in sand stone permafrost. This presentation will give an overview of the RIMFAX investigation, describe the development of the radar system, and show results from field tests of the radar.

  15. Results of the 1000 Hour Rotary Microfilter Endurance Test

    International Nuclear Information System (INIS)

    Herman, D.

    2010-01-01

    During operation, a primary concern is lifetime of the mechanical seal. Leakage from main shaft mechanical seal is expected to be first indication of wear on rotary filter but will not be the ultimate failure of the filter. Initial clearance inadequate to support thermal expansion resulted in initial scarring of journal. Tolerances adjusted and no journal issues were found during 1000 hour test. Disassembly and inspection of the rotary joint seals showed no unusual wear. No leakage observed during test. Total operation time over 1500 hours. Test summary successfully demonstrated: (1) Filtration of a 'challenging' SRS simulant up to 15 wt % insoluble solids in a 5.6 M salt simulant; (2) Sludge washing; (3) In-situ acid cleaning with dilute acid; (4) Over 1000 hours of operation on new journal material; and (5) Over 1500 hours of operation on all seals. The filter out lasted: 2 air compressors, 2 power outages (one planned), 2 chillers, 1 fire, 1 electrical breaker and 1 feed pump seal.

  16. Radioactive Testing Results in Support of the In-Tank Precipitation Facility - Filtrate Test

    International Nuclear Information System (INIS)

    Hobbs, D.T.

    1998-01-01

    This report documents results investigating the decomposition of excess NaTPB in presence of filtrate from one of the Cycle I Demonstration tests, fulfilling a request by CST Engineering and the ITP Flow Sheet Team

  17. Posterior consistency for Bayesian inverse problems through stability and regression results

    International Nuclear Information System (INIS)

    Vollmer, Sebastian J

    2013-01-01

    In the Bayesian approach, the a priori knowledge about the input of a mathematical model is described via a probability measure. The joint distribution of the unknown input and the data is then conditioned, using Bayes’ formula, giving rise to the posterior distribution on the unknown input. In this setting we prove posterior consistency for nonlinear inverse problems: a sequence of data is considered, with diminishing fluctuations around a single truth and it is then of interest to show that the resulting sequence of posterior measures arising from this sequence of data concentrates around the truth used to generate the data. Posterior consistency justifies the use of the Bayesian approach very much in the same way as error bounds and convergence results for regularization techniques do. As a guiding example, we consider the inverse problem of reconstructing the diffusion coefficient from noisy observations of the solution to an elliptic PDE in divergence form. This problem is approached by splitting the forward operator into the underlying continuum model and a simpler observation operator based on the output of the model. In general, these splittings allow us to conclude posterior consistency provided a deterministic stability result for the underlying inverse problem and a posterior consistency result for the Bayesian regression problem with the push-forward prior. Moreover, we prove posterior consistency for the Bayesian regression problem based on the regularity, the tail behaviour and the small ball probabilities of the prior. (paper)

  18. The Space Station Photovoltaic Panels Plasma Interaction Test Program: Test plan and results

    Science.gov (United States)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1989-01-01

    The Plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  19. The Space Station photovoltaic panels plasma interaction test program - Test plan and results

    Science.gov (United States)

    Nahra, Henry K.; Felder, Marian C.; Sater, Bernard L.; Staskus, John V.

    1990-01-01

    The plasma Interaction Test performed on two space station solar array panels is addressed. This includes a discussion of the test requirements, test plan, experimental set-up, and test results. It was found that parasitic current collection was insignificant (0.3 percent of the solar array delivered power). The measured arcing threshold ranged from -210 to -457 V with respect to the plasma potential. Furthermore, the dynamic response of the panels showed the panel time constant to range between 1 and 5 microsec, and the panel capacitance to be between .01 and .02 microF.

  20. Results from laboratory and field testing of nitrate measuring spectrophotometers

    Science.gov (United States)

    Snazelle, Teri T.

    2015-01-01

    Five ultraviolet (UV) spectrophotometer nitrate analyzers were evaluated by the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) during a two-phase evaluation. In Phase I, the TriOS ProPs (10-millimeter (mm) path length), Hach NITRATAX plus sc (5-mm path length), Satlantic Submersible UV Nitrate Analyzer (SUNA, 10-mm path length), and S::CAN Spectro::lyser (5-mm path length) were evaluated in the HIF Water-Quality Servicing Laboratory to determine the validity of the manufacturer's technical specifications for accuracy, limit of linearity (LOL), drift, and range of operating temperature. Accuracy specifications were met in the TriOS, Hach, and SUNA. The stock calibration of the S::CAN required two offset adjustments before the analyzer met the manufacturer's accuracy specification. Instrument drift was observed only in the S::CAN and was the result of leaching from the optical path insert seals. All tested models, except for the Hach, met their specified LOL in the laboratory testing. The Hach's range was found to be approximately 18 milligrams nitrogen per liter (mg-N/L) and not the manufacturer-specified 25 mg-N/L. Measurements by all of the tested analyzers showed signs of hysteresis in the operating temperature tests. Only the SUNA measurements demonstrated excessive noise and instability in temperatures above 20 degrees Celsius (°C). The SUNA analyzer was returned to the manufacturer at the completion of the Phase II field deployment evaluation for repair and recalibration, and the performance of the sensor improved significantly.

  1. Kinetic Modeling of Accelerated Stability Testing Enabled by Second Harmonic Generation Microscopy.

    Science.gov (United States)

    Song, Zhengtian; Sarkar, Sreya; Vogt, Andrew D; Danzer, Gerald D; Smith, Casey J; Gualtieri, Ellen J; Simpson, Garth J

    2018-04-03

    The low limits of detection afforded by second harmonic generation (SHG) microscopy coupled with image analysis algorithms enabled quantitative modeling of the temperature-dependent crystallization of active pharmaceutical ingredients (APIs) within amorphous solid dispersions (ASDs). ASDs, in which an API is maintained in an amorphous state within a polymer matrix, are finding increasing use to address solubility limitations of small-molecule APIs. Extensive stability testing is typically performed for ASD characterization, the time frame for which is often dictated by the earliest detectable onset of crystal formation. Here a study of accelerated stability testing on ritonavir, a human immunodeficiency virus (HIV) protease inhibitor, has been conducted. Under the condition for accelerated stability testing at 50 °C/75%RH and 40 °C/75%RH, ritonavir crystallization kinetics from amorphous solid dispersions were monitored by SHG microscopy. SHG microscopy coupled by image analysis yielded limits of detection for ritonavir crystals as low as 10 ppm, which is about 2 orders of magnitude lower than other methods currently available for crystallinity detection in ASDs. The four decade dynamic range of SHG microscopy enabled quantitative modeling with an established (JMAK) kinetic model. From the SHG images, nucleation and crystal growth rates were independently determined.

  2. Tc-99 Adsorption on Selected Activated Carbons - Batch Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Mattigod, Shas V.; Wellman, Dawn M.; Golovich, Elizabeth C.; Cordova, Elsa A.; Smith, Ronald M.

    2010-12-01

    CH2M HILL Plateau Remediation Company (CHPRC) is currently developing a 200-West Area groundwater pump-and-treat system as the remedial action selected under the Comprehensive Environmental Response, Compensation, and Liability Act Record of Decision for Operable Unit (OU) 200-ZP-1. This report documents the results of treatability tests Pacific Northwest National Laboratory researchers conducted to quantify the ability of selected activated carbon products (or carbons) to adsorb technetium-99 (Tc-99) from 200-West Area groundwater. The Tc-99 adsorption performance of seven activated carbons (J177601 Calgon Fitrasorb 400, J177606 Siemens AC1230AWC, J177609 Carbon Resources CR-1240-AW, J177611 General Carbon GC20X50, J177612 Norit GAC830, J177613 Norit GAC830, and J177617 Nucon LW1230) were evaluated using water from well 299-W19-36. Four of the best performing carbons (J177606 Siemens AC1230AWC, J177609 Carbon Resources CR-1240-AW, J177611 General Carbon GC20X50, and J177613 Norit GAC830) were selected for batch isotherm testing. The batch isotherm tests on four of the selected carbons indicated that under lower nitrate concentration conditions (382 mg/L), Kd values ranged from 6,000 to 20,000 mL/g. In comparison. Under higher nitrate (750 mg/L) conditions, there was a measureable decrease in Tc-99 adsorption with Kd values ranging from 3,000 to 7,000 mL/g. The adsorption data fit both the Langmuir and the Freundlich equations. Supplemental tests were conducted using the two carbons that demonstrated the highest adsorption capacity to resolve the issue of the best fit isotherm. These tests indicated that Langmuir isotherms provided the best fit for Tc-99 adsorption under low nitrate concentration conditions. At the design basis concentration of Tc 0.865 µg/L(14,700 pCi/L), the predicted Kd values from using Langmuir isotherm constants were 5,980 mL/g and 6,870 mL/g for for the two carbons. These Kd values did not meet the target Kd value of 9,000 mL/g. Tests

  3. A bacterial acyl aminoacyl peptidase couples flexibility and stability as a result of cold adaptation.

    Science.gov (United States)

    Brocca, Stefania; Ferrari, Cristian; Barbiroli, Alberto; Pesce, Alessandra; Lotti, Marina; Nardini, Marco

    2016-12-01

    Life in cold environments requires an overall increase in the flexibility of macromolecular and supramolecular structures to allow biological processes to take place at low temperature. Conformational flexibility supports high catalytic rates of enzymes in the cold but in several cases is also a cause of instability. The three-dimensional structure of the psychrophilic acyl aminoacyl peptidase from Sporosarcina psychrophila (SpAAP) reported in this paper highlights adaptive molecular changes resulting in a fine-tuned trade-off between flexibility and stability. In its functional form SpAAP is a dimer, and an increase in flexibility is achieved through loosening of intersubunit hydrophobic interactions. The release of subunits from the quaternary structure is hindered by an 'arm exchange' mechanism, in which a tiny structural element at the N terminus of one subunit inserts into the other subunit. Mutants lacking the 'arm' are monomeric, inactive and highly prone to aggregation. Another feature of SpAAP cold adaptation is the enlargement of the tunnel connecting the exterior of the protein with the active site. Such a wide channel might compensate for the reduced molecular motions occurring in the cold and allow easy and direct access of substrates to the catalytic site, rendering transient movements between domains unnecessary. Thus, cold-adapted SpAAP has developed a molecular strategy unique within this group of proteins: it is able to enhance the flexibility of each functional unit while still preserving sufficient stability. Structural data are available in the Protein Data Bank under the accession number 5L8S. © 2016 Federation of European Biochemical Societies.

  4. First irradiation test results of the ALICE SAMPA ASIC

    CERN Document Server

    Mahmood, Sohail Musa; Winje, Fredrik Lindseth; Velure, Arild

    2018-01-01

    With the continuous scaling of the CMOS technology, the CMOS circuits are considered to be more tolerant to Single event Latchup (SEL) effects due to the reduction in the supply voltages. This paper reports the results from SEL testing performed on the first two prototypes for the new readout ASIC (SAMPA). During RUN 3/RUN 4 at the Large Hadron Collider (LHC), the SAMPA chip will be used for the upgrade of read-out front end electronics of the ALICE (A Large Ion Collider Experiment) Time Projection Chamber (TPC) and Muon Chambers (MCH). The first prototype MPW1 and the second prototype V2 of the SAMPA chip were delivered in 2015 and 2016, respectively. The results are summarized from two different proton beam irradiation campaigns, conducted for SAMPA MPW1 and V2 prototypes at The Svedberg Laboratory (TSL) in Uppsala, and the Center of Advanced Radiation Technology (KVI) in Groningen, respectively.

  5. A statistical test of the stability assumption inherent in empirical estimates of economic depreciation.

    Science.gov (United States)

    Shriver, K A

    1986-01-01

    Realistic estimates of economic depreciation are required for analyses of tax policy, economic growth and production, and national income and wealth. THe purpose of this paper is to examine the stability assumption underlying the econometric derivation of empirical estimates of economic depreciation for industrial machinery and and equipment. The results suggest that a reasonable stability of economic depreciation rates of decline may exist over time. Thus, the assumption of a constant rate of economic depreciation may be a reasonable approximation for further empirical economic analyses.

  6. Test results for cables used in nuclear power plants by a new environmental testing method

    International Nuclear Information System (INIS)

    Handa, Katsue; Fujimura, Shun-ichi; Hayashi, Toshiyasu; Takano, Keiji; Oya, Shingo

    1982-01-01

    In the nuclear power plants using PWRs or BWRs in Japan, environmental tests are provided, in which simulated LOCA conditions are considered so as to conform with Japanese conditions, and many cables which passed these tests are presently employed. Lately, the new environmental testing, in which a credible accident called MSLB (main steam line breakage) is taken into account, is investigated in PWR nuclear power plants, besides LOCA. This paper reports on the results of evaluating some PWR cables for this new environmental testing conditions. The several cables tested were selected out of PH cables (fire-retardant, ethylene propylene rubber insulated, chlorosulfonated polyethylene sheathed cables) as the cables for safety protecting circuits and to be used in containment vessels where the cables are to be exposed to severe environmental test conditions of 2 x 10 8 Rad γ-irradiation and simulated LOCA. All these cables have been accepted after the vertical tray burning test provided in the IEEE Standard 383. The new testing was carried out by sequentially applying thermal deterioration, γ-irradiation, and the exposure to steam (twice 300 s exposures to 190 deg C superheated steam). After completing each step, tensile strength, elongation, insulation resistance and breakdown voltage were measured, respectively. Every cable tested showed satisfactory breakdown voltage after the exposure to steam, thus it was decided to be acceptable. In future, it is required to investigate the influence of the rate of temperature rise on the cable to be tested in MSLB simulation. (Wakatsuki, Y.)

  7. California Bearing Ratio (CBR) test on stabilization of clay with lime addition

    Science.gov (United States)

    Hastuty, I. P.; Roesyanto; Limbong, M. N.; Oberlyn, S. J.

    2018-02-01

    Clay is a type of soil with particles of certain minerals giving plastic properties when mixed with water. Soil has an important role in a construction, besides as a building material in a wide variety of civil engineering works, soil is also used as supporting foundation of the building. Basic properties of clay are rock-solid in dry and plastic with medium water content. In high water content, clay becomes sticky like (cohesive) and soften. Therefore, clay stabilization is necessary to repair soil’s mechanical properties. In this research, lime is use as a stabilizer that contains the Ca+ element to bond bigger particles. Lime used is slaked lime Ca(OH)2. Clay used has liquid limitation (LL) value of 47.33%, plasticity index of 29.88% and CBR value 6.29. The results explain about 10% lime mixture variation gives the optimum stabilized clay with CBR value of 8.75%.

  8. School results and access test results as indicators of first-year performance at university

    Directory of Open Access Journals (Sweden)

    A Bothma

    2004-06-01

    Full Text Available The goals set by the National Plan for Higher Education, the fact that many schools are still severely disadvantaged as well as far-reaching changes in the school system demand that South African universities urgently reconsider their admission procedures. Redesigning admission procedures calls for a thorough understanding of the interrelationships between school marks, results in existing access tests and first-year university performance. These interrelationships were statistically investigated in the case of the 1999, 2000 and 2001 intake groups, who were compelled to write access tests before being admitted to Stellenbosch University. The results of this investigation confirm an alarming degree of unpreparedness among many prospective students regarding what is expected of them at university. This is aggravated by school marks creating a totally unrealistic expectation of performance in the first year at university. It is emphasised that schools and authorities dealing with admission of prospective students at universities should be cognisant of the findings reported here. Furthermore, the statistical analyses demonstrate several novel techniques for investigating the interrelationship between school marks, access test results and university performance.

  9. Polygraph Test Results Assessment by Regression Analysis Methods

    Directory of Open Access Journals (Sweden)

    K. A. Leontiev

    2014-01-01

    Full Text Available The paper considers a problem of defining the importance of asked questions for the examinee under judicial and psychophysiological polygraph examination by methods of mathematical statistics. It offers the classification algorithm based on the logistic regression as an optimum Bayesian classifier, considering weight coefficients of information for the polygraph-recorded physiological parameters with no condition for independence of the measured signs.Actually, binary classification is executed by results of polygraph examination with preliminary normalization and standardization of primary results, with check of a hypothesis that distribution of obtained data is normal, as well as with calculation of coefficients of linear regression between input values and responses by method of maximum likelihood. Further, the logistic curve divided signs into two classes of the "significant" and "insignificant" type.Efficiency of model is estimated by means of the ROC analysis (Receiver Operator Characteristics. It is shown that necessary minimum sample has to contain results of 45 measurements at least. This approach ensures a reliable result provided that an expert-polygraphologist possesses sufficient qualification and follows testing techniques.

  10. Results of industrial tests of carbonate additive to fuel oil

    Science.gov (United States)

    Zvereva, E. R.; Dmitriev, A. V.; Shageev, M. F.; Akhmetvalieva, G. R.

    2017-08-01

    Fuel oil plays an important role in the energy balance of our country. The quality of fuel oil significantly affects the conditions of its transport, storage, and combustion; release of contaminants to atmosphere; and the operation of main and auxiliary facilities of HPPs. According to the Energy Strategy of Russia for the Period until 2030, the oil-refining ratio gradually increases; as a result, the fraction of straight-run fuel oil in heavy fuel oils consistently decreases, which leads to the worsening of performance characteristics of fuel oil. Consequently, the problem of the increase in the quality of residual fuel oil is quite topical. In this paper, it is suggested to treat fuel oil by additives during its combustion, which would provide the improvement of ecological and economic indicators of oil-fired HPPs. Advantages of this method include simplicity of implementation, low energy and capital expenses, and the possibility to use production waste as additives. In the paper, the results are presented of industrial tests of the combustion of fuel oil with the additive of dewatered carbonate sludge, which is formed during coagulation and lime treatment of environmental waters on HPPs. The design of a volume delivery device is developed for the steady additive input to the boiler air duct. The values are given for the main parameters of the condition of a TGM-84B boiler plant. The mechanism of action of dewatered carbonate sludge on sulfur oxides, which are formed during fuel oil combustion, is considered. Results of industrial tests indicate the decrease in the mass fraction of discharged sulfur oxides by 36.5%. Evaluation of the prevented damage from sulfur oxide discharged into atmospheric air shows that the combustion of the fuel oil of 100 brand using carbonate sludge as an additive (0.1 wt %) saves nearly 6 million rubles a year during environmental actions at the consumption of fuel oil of 138240 t/year.

  11. Structural Stability Monitoring of a Physical Model Test on an Underground Cavern Group during Deep Excavations Using FBG Sensors

    Directory of Open Access Journals (Sweden)

    Yong Li

    2015-08-01

    Full Text Available Fiber Bragg Grating (FBG sensors are comprehensively recognized as a structural stability monitoring device for all kinds of geo-materials by either embedding into or bonding onto the structural entities. The physical model in geotechnical engineering, which could accurately simulate the construction processes and the effects on the stability of underground caverns on the basis of satisfying the similarity principles, is an actual physical entity. Using a physical model test of underground caverns in Shuangjiangkou Hydropower Station, FBG sensors were used to determine how to model the small displacements of some key monitoring points in the large-scale physical model during excavation. In the process of building the test specimen, it is most successful to embed FBG sensors in the physical model through making an opening and adding some quick-set silicon. The experimental results show that the FBG sensor has higher measuring accuracy than other conventional sensors like electrical resistance strain gages and extensometers. The experimental results are also in good agreement with the numerical simulation results. In conclusion, FBG sensors could effectively measure small displacements of monitoring points in the whole process of the physical model test. The experimental results reveal the deformation and failure characteristics of the surrounding rock mass and make some guidance for the in situ engineering construction.

  12. Test Results and Comparison of Triaxial Strength Testing of Waste Isolation Pilot Plant Clean Salt

    Energy Technology Data Exchange (ETDEWEB)

    Buchholz, Stuart A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-12-01

    This memorandum documents laboratory thermomechanical triaxial strength testing of Waste Isolation Pilot Plant (WIPP) clean salt. The limited study completed independent, adjunct laboratory tests in the United States to assist in validating similar testing results being provided by the German facilities. The testing protocol consisted of completing confined triaxial, constant strain rate strength tests of intact WIPP clean salt at temperatures of 25°C and 100°C and at multiple confining pressures. The stratigraphy at WIPP also includes salt that has been labeled “argillaceous.” The much larger test matrix conducted in Germany included both the so-called clean and argillaceous salts. When combined, the total database of laboratory results will be used to develop input parameters for models, assess adequacy of existing models, and predict material behavior. These laboratory studies are also consistent with the goals of the international salt repository research program. The goal of this study was to complete a subset of a test matrix on clean salt from the WIPP undertaken by German research groups. The work was performed at RESPEC in Rapid City, South Dakota. A rigorous Quality Assurance protocol was applied, such that corroboration provides the potential of qualifying all of the test data gathered by German research groups.

  13. Fission Surface Power Technology Demonstration Unit Test Results

    Science.gov (United States)

    Briggs, Maxwell H.; Gibson, Marc A.; Geng, Steven M.; Sanzi, James L.

    2016-01-01

    The Fission Surface Power (FSP) Technology Demonstration Unit (TDU) is a system-level demonstration of fission power technology intended for use on manned missions to Mars. The Baseline FSP systems consists of a 190 kWt UO2 fast-spectrum reactor cooled by a primary pumped liquid metal loop. This liquid metal loop transfers heat to two intermediate liquid metal loops designed to isolate fission products in the primary loop from the balance of plant. The intermediate liquid metal loops transfer heat to four Stirling Power Conversion Units (PCU), each of which produce 12 kWe (48 kW total) and reject waste heat to two pumped water loops, which transfer the waste heat to titanium-water heat pipe radiators. The FSP TDU simulates a single leg of the baseline FSP system using an electrically heater core simulator, a single liquid metal loop, a single PCU, and a pumped water loop which rejects the waste heat to a Facility Cooling System (FCS). When operated at the nominal operating conditions (modified for low liquid metal flow) during TDU testing the PCU produced 8.9 kW of power at an efficiency of 21.7 percent resulting in a net system power of 8.1 kW and a system level efficiency of 17.2 percent. The reduction in PCU power from levels seen during electrically heated testing is the result of insufficient heat transfer from the NaK heater head to the Stirling acceptor, which could not be tested at Sunpower prior to delivery to the NASA Glenn Research Center (GRC). The maximum PCU power of 10.4 kW was achieved at the maximum liquid metal temperature of 875 K, minimum water temperature of 350 K, 1.1 kg/s liquid metal flow, 0.39 kg/s water flow, and 15.0 mm amplitude at an efficiency of 23.3 percent. This resulted in a system net power of 9.7 kW and a system efficiency of 18.7 percent.

  14. Stenting is improving and stabilizing anatomical results of coiled intracranial aneurysms

    International Nuclear Information System (INIS)

    Lubicz, Boris; Bandeira, Alexandra; Baleriaux, Danielle; Bruneau, Michael; Witte, Olivier de; Dewindt, Aloys

    2009-01-01

    Stent-assisted coiling (SAC) is an alternative to surgical clipping for the treatment of wide-necked intracranial aneurysms (IA). However, little information is available concerning the long-term results of this treatment. The aim of this study was to report the long-term clinical and anatomical findings in 32 patients with 34 wide-necked IA treated by SAC. A retrospective review of our prospectively maintained database identified all patients followed up for wide-necked IA treated by SAC. The clinical charts, procedural data, and angiographic results were reviewed. Thirty-two patients with 34 IA were identified including 25 asymptomatic patients, four with cranial nerve palsies, two with a subarachnoid hemorrhage, and one with transient ischemic attacks. Mean aneurysm size was 10.2 mm (range 3.5 to 26 mm). Embolization was successful in all patients and no procedure-related neurological morbidity or mortality was observed. Immediate anatomical results included nine complete occlusions (26.5%), two neck remnants (6%), and 23 incomplete occlusions (67.5%). Mean imaging follow-up of 20 months showed 18 further thrombosis (53%) and 16 stable results (47%). Finally, 27 aneurysms were completely occluded (79%), three had a neck remnant (9%), and four were incompletely occluded (12%). Asymptomatic and nonsignificant in-stent stenosis occurred in seven patients (22%). SAC is safe and effective for the treatment of wide-necked IA. Despite unsatisfying immediate aneurysm occlusion, the adjunctive effect of the stent is stabilizing or significantly improving long-term anatomical results. (orig.)

  15. Results of conductor testing in SULTAN a review

    CERN Document Server

    Wesche, R; Bruzzone, P; Calvi, M; Cau, F; Herzog, R; Marinucci, C; Stepanov, B

    2009-01-01

    In the last few years, the DC performance of a large number of sub- and full-size NbTi as well as Nb3Sn cablein- conduit (CIC) conductors was tested in the SULTAN facility of CRPP. The “potential” DC performance of various CIC conductors was estimated from the measured strand data. In the present work, the DC performance of CIC conductors, measured in SULTAN, is compared with this “potential” DC performance. The DC performance of NbTi sub- and full size CIC conductors has been found to be in good agreement with the “potential” conductor performance. For Nb3Sn CIC conductors, the situation is more complex because of the strain sensitivity of the critical current. Evidence for strand damage, caused by the large Lorentz forces, has been found in Nb3Sn subsize conductors. Finally, a summary of the results of the tests of the ITER-TF Nb3Sn conductors is provided. Again the measured DC performance is compared to the "potential" performance.

  16. Ground Operations Demonstration Unit for Liquid Hydrogen Initial Test Results

    Science.gov (United States)

    Notardonato, W. U.; Johnson, W. L.; Swanger, A. M.; Tomsik, T.

    2015-01-01

    NASA operations for handling cryogens in ground support equipment have not changed substantially in 50 years, despite major technology advances in the field of cryogenics. NASA loses approximately 50% of the hydrogen purchased because of a continuous heat leak into ground and flight vessels, transient chill down of warm cryogenic equipment, liquid bleeds, and vent losses. NASA Kennedy Space Center (KSC) needs to develop energy-efficient cryogenic ground systems to minimize propellant losses, simplify operations, and reduce cost associated with hydrogen usage. The GODU LH2 project has designed, assembled, and started testing of a prototype storage and distribution system for liquid hydrogen that represents an advanced end-to-end cryogenic propellant system for a ground launch complex. The project has multiple objectives including zero loss storage and transfer, liquefaction of gaseous hydrogen, and densification of liquid hydrogen. The system is unique because it uses an integrated refrigeration and storage system (IRAS) to control the state of the fluid. This paper will present and discuss the results of the initial phase of testing of the GODU LH2 system.

  17. Drop Test Results of CRDM under Seismic Loads

    International Nuclear Information System (INIS)

    Choi, Myoung-Hwan; Cho, Yeong-Garp; Kim, Gyeong-Ho; Sun, Jong-Oh; Huh, Hyung

    2016-01-01

    This paper describes the test results to demonstrate the drop performance of CRDM under seismic loads. The top-mounted CRDM driven by the stepping motor for Jordan Research and Training Reactor (JRTR) has been developed in KAERI. The CRDM for JRTR has been optimized by the design improvement based on that of the HANARO. It is necessary to verify the drop performance under seismic loads such as operating basis earthquake (OBE) and safe shutdown earthquake (SSE). Especially, the CAR drop times are important data for the safety analysis. confirm the drop performance under seismic loads. The delay of drop time at Rig no. 2 due to seismic loads is greater than that at Rig no. 3. The total pure drop times under seismic loads are estimated as 1.169 and 1.855, respectively

  18. Business jet approach noise abatement techniques - Flight test results

    Science.gov (United States)

    Putnam, T. W.; Burcham, F. W.

    1976-01-01

    Operational techniques for reducing approach noise from business jet aircraft were evaluated in flight by measuring the noise generated by five such aircraft during modified approaches. Approaches with 4-deg glide slopes were approximately 4.0 EPNdB quieter than approaches with standard 3-deg glide slopes. Noise reductions for low-drag 3-deg approaches varied widely among the airplanes tested; the fleet-weighted reduction was 8.5 EPNdB. Two-segment approaches resulted in noise reductions of 7.0 EPNdB to 8.5 EPNdB 3 nautical miles and 5 nautical miles from touchdown. Pilot workload increased progressively for the 4-deg, low-drag 3-deg, and two-segment approach.

  19. Stirling cryocooler test results and design model verification

    International Nuclear Information System (INIS)

    Shimko, M.A.; Stacy, W.D.; McCormick, J.A.

    1990-01-01

    This paper reports on progress in developing a long-life Stirling cycle cryocooler for space borne applications. It presents the results from tests on a preliminary breadboard version of the cryocooler used to demonstrate the feasibility of the technology and to validate the regenerator design code used in its development. This machine achieved a cold-end temperature of 65 K while carrying a 1/2 Watt cooling load. The basic machine is a double-acting, flexure-bearing, split Stirling design with linear electromagnetic drives for the expander and compressors. Flat metal diaphragms replace pistons for both sweeping and sealing the machine working volumes. In addition, the double-acting expander couples to a laminar-channel counterflow recuperative heat exchanger for regeneration. A PC compatible design code was developed for this design approach that calculates regenerator loss including heat transfer irreversibilities, pressure drop, and axial conduction in the regenerator walls

  20. Postirradiation examination results for the irradiation effects scoping test 1

    International Nuclear Information System (INIS)

    Mehner, A.S.; Quapp, W.J.; Goetzmann, O.; Hobbins, R.R.

    1976-09-01

    A zircaloy-clad UO 2 fuel rod was operated above its critical heat flux within the in-pile test loop of the Power Burst Facility and later examined in the hot cells. The results of the postirradiation examinations are presented in this report. A Zr-UO 2 reaction at the fuel-cladding interface embrittled nearly as much of the cladding wall thickness as the Zr-water reaction on the exterior. Data on both the internal and external reactions, and cladding and fuel microstructures, are presented. Cladding embrittlement and rod failure are compared with several rod fragmentation criteria, and conclusions concerning fuel rod failure propagation in a power reactor system are made

  1. Postirradiation examination results for the irradiation effects scoping test 1

    Energy Technology Data Exchange (ETDEWEB)

    Mehner, A.S.; Quapp, W.J.; Goetzmann, O.; Hobbins, R.R.

    1976-09-01

    A zircaloy-clad UO/sub 2/ fuel rod was operated above its critical heat flux within the in-pile test loop of the Power Burst Facility and later examined in the hot cells. The results of the postirradiation examinations are presented in this report. A Zr-UO/sub 2/ reaction at the fuel-cladding interface embrittled nearly as much of the cladding wall thickness as the Zr-water reaction on the exterior. Data on both the internal and external reactions, and cladding and fuel microstructures, are presented. Cladding embrittlement and rod failure are compared with several rod fragmentation criteria, and conclusions concerning fuel rod failure propagation in a power reactor system are made.

  2. The GEWEX water vapor assessment (G-VAP) - results from inter-comparisons and stability analysis

    Science.gov (United States)

    Schroeder, Marc; Lockhoff, Maarit; Shi, Lei

    2017-04-01

    A large variety of water vapour data records is available to date. Without proper background information and understanding of the limitations of available data records, these data may be incorrectly utilised or misinterpreted. The overall goal of assessments of CDRs is to conduct objective and independent evaluations and inter-comparisons in order to point out strengths, differences and limitations and, if possible, to provide reasons for them. The need for such assessments is part of the GCOS guidelines for the generation of data products. The GEWEX Data and Assessments Panel (GDAP) has initiated the GEWEX water vapor assessment (G-VAP) which has the major purpose to quantify the current state of the art in water vapour products (upper tropospheric humidity, specific humidity and temperature profiles as well as total column water vapour) being constructed for climate applications. In order to support GDAP and the general climate analysis community G-VAP intends to answer, among others, the following questions: a) How large are the differences in observed temporal changes in long-term satellite data records of water vapour on global and regional scales? b) Are the differences in observed temporal changes within uncertainty limits? c) What is the degree of homogeneity (break points) of each long-term satellite data record? A general overview of G-VAP will be given. The focus of the presentation will be on observed inconsistencies among the long-term satellite data records as observed by inter-comparisons and comparison to in-situ observations and the stability analysis. On basis of consistently applied tools major differences in state-of-art CDRs have been identified, documented and to a large extend explained. The results and the answers for TCWV are summarized as follows: On global ice free ocean scale the trend estimates among long-term data records were generally found to be significantly different. Maxima in standard deviation among the data records are found

  3. Acoustic conditions in open plan offices – Pilot test results

    Directory of Open Access Journals (Sweden)

    Witold Mikulski

    2016-10-01

    Full Text Available Background: The main source of noise in open plan office are conversations. Office work standards in such premises are attained by applying specific acoustic adaptation. This article presents the results of pilot tests and acoustic evaluation of open space rooms. Material and Methods: Acoustic properties of 6 open plan office rooms were the subject of the tests. Evaluation parameters, measurement methods and criterial values were adopted according to the following standards: PN-EN ISO 3382- 3:2012, PN-EN ISO 3382-2:2010, PN-B-02151-4:2015-06 and PN-B-02151-3:2015-10. Results: The reverberation time was 0.33– 0.55 s (maximum permissible value in offices – 0.6 s; the criterion was met, sound absorption coefficient in relation to 1 m2 of the room’s plan was 0.77–1.58 m2 (minimum permissible value – 1.1 m2; 2 out of 6 rooms met the criterion, distraction distance was 8.5–14 m (maximum permissible value – 5 m; none of the rooms met the criterion, A-weighted sound pressure level of speech at a distance of 4 m was 43.8–54.7 dB (maximum permissible value – 48 dB; 2 out of 6 rooms met the criterion, spatial decay rate of the speech was 1.8–6.3 dB (minimum permissible value – 7 dB; none of the rooms met the criterion. Conclusions: Standard acoustic treatment, containing sound absorbing suspended ceiling, sound absorbing materials on the walls, carpet flooring and sound absorbing workplace barriers, is not sufficient. These rooms require specific advanced acoustic solutions. Med Pr 2016;67(5:653–662

  4. Influence of blood lipids on global coagulation test results.

    Science.gov (United States)

    Kim, Jung-Ah; Kim, Ji-Eun; Song, Sang Hoon; Kim, Hyun Kyung

    2015-01-01

    High levels of blood lipids have been associated with high levels of coagulation factors. We investigated whether blood lipids influence the results of global coagulation tests, including prothrombin time (PT), activated partial thromboplastin time (aPTT), and thrombin generation assay (TGA). PT, aPTT, and TGA, along with procoagulant and anticoagulant factors, were measured in 488 normal individuals. Vitamin K status was assessed with prothrombin-induced by vitamin K absence-II (PIVKA-II). The procoagulant factors II, VII, IX, X, and XI and anticoagulant factors protein C and protein S showed significant correlations with triglyceride, and the procoagulant factors II, V, VII, IX, X, XI, and XII and anticoagulant factors antithrombin and protein C correlated with total cholesterol. There were no correlations of blood lipid levels with PIVKA-II levels. Subjects with high triglyceride levels (≥200 mg/dL) showed shorter PT values than those with lower triglyceride levels. However, aPTT value was not changed in terms of blood lipid levels. In both 1 and 5 pM tissue factor-induced TGAs, subjects in the high-triglyceride or high-cholesterol groups (≥240 mg/dL) had high levels of lag time, time-to-peak, and endogenous thrombin potential. Total cholesterol was a significant determinant of PT and TGA values. High blood lipids were related with increased coagulation activity in a normal population. Our findings are expected to help interpret the global coagulation test results in individuals with high lipid levels.

  5. Nonlinear Analysis and Preliminary Testing Results of a Hybrid Wing Body Center Section Test Article

    Science.gov (United States)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.; Wu, Hsi-Yung T.

    2015-01-01

    A large test article was recently designed, analyzed, fabricated, and successfully tested up to the representative design ultimate loads to demonstrate that stiffened composite panels with through-the-thickness reinforcement are a viable option for the next generation large transport category aircraft, including non-conventional configurations such as the hybrid wing body. This paper focuses on finite element analysis and test data correlation of the hybrid wing body center section test article under mechanical, pressure and combined load conditions. Good agreement between predictive nonlinear finite element analysis and test data is found. Results indicate that a geometrically nonlinear analysis is needed to accurately capture the behavior of the non-circular pressurized and highly-stressed structure when the design approach permits local buckling.

  6. Bone cement penetration pattern and primary stability testing in keeled and pegged glenoid components.

    Science.gov (United States)

    Raiss, Patric; Pape, Guido; Kleinschmidt, Kerstin; Jäger, Sebastian; Sowa, Boris; Jakubowitz, Eike; Loew, Markus; Bruckner, Thomas; Rickert, Markus

    2011-07-01

    It has been proposed that bone mineral density has an influence on cement penetration in hip and knee arthroplasty. The hypotheses of this study were that: 1) there is a negative correlation between bone mineral density (BMD) and cement penetration in cemented glenoid components; and 2) that implant design has an influence on cement penetration into the glenoid bone. BMD of 10 pairs of fresh frozen scapulas was measured. Micro-computed tomography (micro-CT) scans in 3 different sections were analyzed after implantation of keeled and pegged glenoid components using a 3(rd)-generation cementing technique with a vacuum mixing system. Cement penetration was analyzed and correlated with BMD. Pull-out strength testing was performed to analyze primary stability. The overall peak BMD was 0.6 [g/cm(2)] (range, 0.33-0.98). A strong negative correlation between BMD and mean cement penetration was found for the peg (R(2) = -.83; P penetration was 78.4 mm(2) (range, 60.6-94.2) in the keel and 113.9 mm(2) (range, 78.2-143.4) in the peg group (P < .0001). In all cases, the components were pulled out of the cement mantle, whereas the bone-cement interfaces remained intact. The mean pull-out strength was 1093N (764-1343N) for keeled and 884N (650-1264N) for pegged components (P < .05). A modern cementing technique, leading to a deep bonding between bone and cement, is crucial to prevent loosening of glenoid components. The findings of this study might help us to better understand the results of follow-up studies of cemented glenoid implants. Our results could be helpful for the choice of implants in patients with poor bone quality like osteoporosis or rheumatoid arthritis. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  7. 'False-positive' and 'false-negative' test results in clinical urine drug testing.

    Science.gov (United States)

    Reisfield, Gary M; Goldberger, Bruce A; Bertholf, Roger L

    2009-08-01

    The terms 'false-positive' and 'false-negative' are widely used in discussions of urine drug test (UDT) results. These terms are inadequate because they are used in different ways by physicians and laboratory professionals and they are too narrow to encompass the larger universe of potentially misleading, inappropriate and unexpected drug test results. This larger universe, while not solely comprised of technically 'true' or 'false' positive or negative test results, presents comparable interpretive challenges with corresponding clinical implications. In this review, we propose the terms 'potentially inappropriate' positive or negative test results in reference to UDT results that are ambiguous or unexpected and subject to misinterpretation. Causes of potentially inappropriate positive UDT results include in vivo metabolic conversions of a drug, exposure to nonillicit sources of a drug and laboratory error. Causes of potentially inappropriate negative UDT results include limited assay specificity, absence of drug in the urine, presence of drug in the urine, but below established assay cutoff, specimen manipulation and laboratory error. Clinical UDT interpretation is a complicated task requiring knowledge of recent prescription, over-the-counter and herbal drug administration, drug metabolism and analytical sensitivities and specificities.

  8. Rice Husk Ash to Stabilize Heavy Metals Contained in Municipal Solid Waste Incineration Fly Ash: First Results by Applying New Pre-treatment Technology

    Directory of Open Access Journals (Sweden)

    Laura Benassi

    2015-10-01

    Full Text Available A new technology was recently developed for municipal solid waste incineration (MSWI fly ash stabilization, based on the employment of all waste and byproduct materials. In particular, the proposed method is based on the use of amorphous silica contained in rice husk ash (RHA, an agricultural byproduct material (COSMOS-RICE project. The obtained final inert can be applied in several applications to produce “green composites”. In this work, for the first time, a process for pre-treatment of rice husk, before its use in the stabilization of heavy metals, based on the employment of Instant Pressure Drop technology (DIC was tested. The aim of this work is to verify the influence of the pre-treatment on the efficiency on heavy metals stabilization in the COSMOS-RICE technology. DIC technique is based on a thermomechanical effect induced by an abrupt transition from high steam pressure to a vacuum, to produce changes in the material. Two different DIC pre-treatments were selected and thermal annealing at different temperatures were performed on rice husk. The resulting RHAs were employed to obtain COSMOS-RICE samples, and the stabilization procedure was tested on the MSWI fly ash. In the frame of this work, some thermal treatments were also realized in O2-limiting conditions, to test the effect of charcoal obtained from RHA on the stabilization procedure. The results of this work show that the application of DIC technology into existing treatment cycles of some waste materials should be investigated in more details to offer the possibility to stabilize and reuse waste.

  9. Rice Husk Ash to Stabilize Heavy Metals Contained in Municipal Solid Waste Incineration Fly Ash: First Results by Applying New Pre-treatment Technology

    Science.gov (United States)

    Benassi, Laura; Franchi, Federica; Catina, Daniele; Cioffi, Flavio; Rodella, Nicola; Borgese, Laura; Pasquali, Michela; Depero, Laura E.; Bontempi, Elza

    2015-01-01

    A new technology was recently developed for municipal solid waste incineration (MSWI) fly ash stabilization, based on the employment of all waste and byproduct materials. In particular, the proposed method is based on the use of amorphous silica contained in rice husk ash (RHA), an agricultural byproduct material (COSMOS-RICE project). The obtained final inert can be applied in several applications to produce “green composites”. In this work, for the first time, a process for pre-treatment of rice husk, before its use in the stabilization of heavy metals, based on the employment of Instant Pressure Drop technology (DIC) was tested. The aim of this work is to verify the influence of the pre-treatment on the efficiency on heavy metals stabilization in the COSMOS-RICE technology. DIC technique is based on a thermomechanical effect induced by an abrupt transition from high steam pressure to a vacuum, to produce changes in the material. Two different DIC pre-treatments were selected and thermal annealing at different temperatures were performed on rice husk. The resulting RHAs were employed to obtain COSMOS-RICE samples, and the stabilization procedure was tested on the MSWI fly ash. In the frame of this work, some thermal treatments were also realized in O2-limiting conditions, to test the effect of charcoal obtained from RHA on the stabilization procedure. The results of this work show that the application of DIC technology into existing treatment cycles of some waste materials should be investigated in more details to offer the possibility to stabilize and reuse waste. PMID:28793605

  10. Phosphate Management: FY2010 Results Of Phosphate Precipitation Tests

    International Nuclear Information System (INIS)

    Hay, M.; King, W.

    2011-01-01

    The Phosphate Management program seeks to develop treatment options for caustic phosphate solutions resulting from the caustic leaching of the bismuth phosphate sludge. The SRNL subtask investigated the precipitation of phosphate salts from caustic solutions through addition of fluoride and by crystallization. The scoping tests examined the: precipitation of phosphate by the addition of sodium fluoride to form the sodium fluorophosphate double salt, Na 7 F(PO 4 ) 2 · 19H 2 O, crystallization of phosphate by reducing the temperature of saturated phosphate solutions, and combinations of precipitation and crystallization. A simplified leachate simulant was used in the study produced by dissolving sodium phosphate in 1 M to 3.5 M sodium hydroxide solutions. The results show that all three processes; precipitation with sodium fluoride, crystallization, and combined precipitation/crystallization can be effective for removing large amounts of phosphate from solution. The combined process of precipitation/crystallization showed >90% removal of phosphate at all hydroxide concentrations when cooling a non-saturated phosphate solution from 65 C to 25 C. Based on the measured solubility of sodium phosphate, pH adjustment/caustic addition will also remove large amounts of phosphate from solution (>80%). For all three processes, the phosphate concentration in the caustic solution must be managed to keep the phosphate from becoming too concentrated and thereby potentially forming a solid mass of sodium phosphate after an effective phosphate removal process.

  11. Radiation pasteurization of poultry feed: Preliminary results of feeding tests

    International Nuclear Information System (INIS)

    Borsa, J.; Guenter, B.

    1992-01-01

    Feed used to rear farm animals for human consumption has often been implicated as a vehicle for dissemination of microbial pathogens that can adversely affect both animals or birds, and humans. Radiation pasteurization of animal feed to improve its microbiological quality should reduce the incidence of feed-borne infection in the herd or flock. This would result in safer food for the consumer, and improved economic performance of the production unit. This latter benefit is particularly important because it would directly offset the cost of treating the feed. The likelihood of occurrence, as well as the magnitude, of any improved economic performance in the herd or flock consuming the irradiated feed must be determined experimentally. Accordingly, short term feeding tests were carried out to determine the effect of radiation pasteurization of poultry feed on growth performance of young chicks. The results suggest that radiation pasteurization of poultry feed may have a beneficial effect on the feed conversion efficiency of the birds consuming that feed. 10 refs, 8 tabs

  12. A blast absorber test: measurement and model results

    NARCIS (Netherlands)

    Eerden, F.J.M. van der; Berg, F. van den; Hof, J. van 't; Arkel, E. van

    2006-01-01

    A blast absorber test was conducted at the Aberdeen Test Centre from 13 to 17 June 2005. The test was set up to determine the absorbing and shielding effect of a gravel pile, of 1.5 meters high and 15 by 15 meters wide, on blasts from large weapons: e.g. armor, artillery or demolition. The blast was

  13. Stabilizing and destabilizing effects of damping in non-conservative systems: Some new results

    Science.gov (United States)

    Abdullatif, Mahmoud; Mukherjee, Ranjan; Hellum, Aren

    2018-01-01

    Previous work has amply demonstrated that non-conservative systems can be made unstable by the application of damping. Systems with two neutrally-stable damping levels, whereby the system initially gains stability but later loses stability as the level of damping is increased, have also been observed. The phenomenon of three damping-induced stability transitions has not been reported in the literature. Here we show that the addition of damping can cause non-conservative systems to become stable, then unstable, then stable again at the same value of the non-conservative forcing variable. This combination of stability transitions is found to exist for several example systems, including linkages with follower end forces and fluid-conveying pipes. Another interesting observation is that a given system can exhibit different forms of stability transitions in different regions of its parameter space. In a particular example, the neutral stability curves corresponding to two different modes are observed to intersect, such that the boundary separating the stable and unstable regions is piecewise continuous. This observation requires that the accepted definitions of "stabilizing" and "destabilizing" roles of damping be revised. All of these stability transition behaviors were found by applying the Routh-Hurwitz procedure, whereby the traditional procedure is first applied to the characteristic polynomial of the system, and then again to guarantee the existence of a second-order auxiliary polynomial in the Routh array. This procedure is developed in the context of examples, each of which concerns a classical apparatus who dynamics are more interesting than previously believed.

  14. Test results on systems developed for SST-1 tokamak

    International Nuclear Information System (INIS)

    Bora, D.

    2003-01-01

    used for heating the plasma while lower hybrid waves will be used for non inductive current drive (LHCD). A Neutral Beam Injection (NBI) with peak power of 0.8 MW with variable beam energy in range of 10-80 keV will be used as additional auxiliary heating system. A number of proto-types for various critical components have confirmed the fabrication methodology. The fabrication of most of the subsystems is nearing completion and many components have already been accepted at site. Erection and installation of the base of the mechanical structure has already been initiated in the SST hall. This paper reports on the results of the tests on various prototypes and actual components to be used on SST-1 for various subsystems. (author)

  15. NOx Abatement Pilot Plant 90-day test results report

    International Nuclear Information System (INIS)

    McCray, J.A.; Boardman, R.D.

    1991-01-01

    High-level radioactive liquid wastes produced during nuclear fuel reprocessing at the Idaho Chemical Processing Plant are calcined in the New Waste Calcining Facility (NWCF) to provide both volume reduction and a more stable waste form. Because a large component of the HLW is nitric acid, high levels of oxides of nitrogen (NO x ) are produced in the process and discharged to the environment via the calciner off-gas. The NO x abatement program is required by the new Fuel Processing Restoration (FPR) project permit to construct to reduce NO x emissions from the NWCF. Extensive research and development has indicated that the selective catalytic reduction (SCR) process is the most promising technology for treating the NWCF off-gas. Pilot plant tests were performed to determine the compatibility of the SCR process with actual NWCF off-gas. Test results indicate that the SCR process is a viable method for abating the NO x from the NWCF off-gas. Reduction efficiencies over 95% can be obtained, with minimal amounts of ammonia slip, provided favorable operating conditions exist. Two reactors operated with series flow will provide optimum reduction capabilities. Typical operation should be performed with a first reactor stage gas space velocity of 20,000 hr -1 and an inlet temperature of 320 degrees C. The first stage exhaust NO x concentration will then dictate the parameter settings for the second stage. Operation should always strive for a peak reactor temperature of 520 degrees C in both reactors, with minimal NH 3 slip from the second reactor. Frequent fluctuations in the NWCF off-gas NO x concentration will require a full-scale reduction facility that is versatile and quick-responding. Sudden changes in NWCF off-gas NO x concentrations will require quick detection and immediate response to avoid reactor bed over-heating and/or excessive ammonia slip

  16. Automated Critical Peak Pricing Field Tests: Program Descriptionand Results

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Xu, Peng

    2006-04-06

    California utilities have been exploring the use of critical peak prices (CPP) to help reduce needle peaks in customer end-use loads. CPP is a form of price-responsive demand response (DR). Recent experience has shown that customers have limited knowledge of how to operate their facilities in order to reduce their electricity costs under CPP (Quantum 2004). While the lack of knowledge about how to develop and implement DR control strategies is a barrier to participation in DR programs like CPP, another barrier is the lack of automation of DR systems. During 2003 and 2004, the PIER Demand Response Research Center (DRRC) conducted a series of tests of fully automated electric demand response (Auto-DR) at 18 facilities. Overall, the average of the site-specific average coincident demand reductions was 8% from a variety of building types and facilities. Many electricity customers have suggested that automation will help them institutionalize their electric demand savings and improve their overall response and DR repeatability. This report focuses on and discusses the specific results of the Automated Critical Peak Pricing (Auto-CPP, a specific type of Auto-DR) tests that took place during 2005, which build on the automated demand response (Auto-DR) research conducted through PIER and the DRRC in 2003 and 2004. The long-term goal of this project is to understand the technical opportunities of automating demand response and to remove technical and market impediments to large-scale implementation of automated demand response (Auto-DR) in buildings and industry. A second goal of this research is to understand and identify best practices for DR strategies and opportunities. The specific objectives of the Automated Critical Peak Pricing test were as follows: (1) Demonstrate how an automated notification system for critical peak pricing can be used in large commercial facilities for demand response (DR). (2) Evaluate effectiveness of such a system. (3) Determine how customers

  17. Stability of FDG-PET Radiomics features - An integrated analysis of test-retest and inter-observer variability

    Energy Technology Data Exchange (ETDEWEB)

    Leijenaar, Ralph T. H.; Carvalho, Sara; Rios Velazquez, Emmanuel [Dept. of Radiation Oncology (MAASTRO), GROW-School for Oncology and Developmental Biology, Maastricht Univ. Medical Center, Maastricht (Netherlands)] [and others

    2013-10-15

    Purpose: Besides basic measurements as maximum standardized uptake value (SUV){sub max} or SUV{sub mean} derived from 18F-FDG positron emission tomography (PET) scans, more advanced quantitative imaging features (i.e. 'Radiomics' features) are increasingly investigated for treatment monitoring, outcome prediction, or as potential biomarkers. With these prospected applications of Radiomics features, it is a requisite that they provide robust and reliable measurements. The aim of our study was therefore to perform an integrated stability analysis of a large number of PET-derived features in non-small cell lung carcinoma (NSCLC), based on both a test-retest and an inter-observer setup. Methods: Eleven NSCLC patients were included in the test-retest cohort. Patients underwent repeated PET imaging within a one day interval, before any treatment was delivered. Lesions were delineated by applying a threshold of 50 % of the maximum uptake value within the tumor. Twenty-three NSCLC patients were included in the inter-observer cohort. Patients underwent a diagnostic whole body PET-computed tomography (CT). Lesions were manually delineated based on fused PET-CT, using a standardized clinical delineation protocol. Delineation was performed independently by five observers, blinded to each other. Fifteen first order statistics, 39 descriptors of intensity volume histograms, eight geometric features and 44 textural features were extracted. For every feature, test-retest and inter-observer stability was assessed with the intra-class correlation coefficient (ICC) and the coefficient of variability, normalized to mean and range. Similarity between test-retest and inter-observer stability rankings of features was assessed with Spear man's rank correlation coefficient. Results: Results showed that the majority of assessed features had both a high test-retest (71%) and inter-observer (91%) stability in terms of their ICC. Overall, features more stable in repeated PET

  18. FY 1991 report on the results of the demonstration test on the methanol conversion at oil-fired power plant. Feasibility study of a new system for the stabilized supply of fuel use methanol; 1991 nendo sekiyu karyoku hatsudensho metanoru tenkan tou jissho shiken. Nenryo you metanoru kyokyu antei ka no tameno shin system no kanosei chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1992-03-01

    As a part of the project on the demonstration test on the methanol conversion at oil-fired power plant, feasibility study was made of a new system for methanol production by using abundant hydraulic power energy overseas and by combining water electrolysis and coal gasification technology, and the FY 1991 results were summarized. As a result of the survey, the following were selected as water electrolysis facilities: high efficiency/high current density/simplification system and solid polyelectrolyte electrolysis system with a high purity of hydrogen gas. As the coal gasifier, the oxygen blown furnace was selected which has a high carbon utilization factor, is able to gasify coal at high pressure, has no unnecessary N{sub 2}, and is being used in the integrated coal gasification combined cycle power system. As methanol synthesis facilities, the MGC/MHI method super converter was selected. Assuming the output of hydroelectric power generation to be 4,000MW, conceptual design of the optimum system was made. The methanol cost was estimated under the conditions written below: cost of hydroelectric power generation at site: 2-5 yen/kWh, coal unit price at site: 5,000-6,000 yen/t, transportation distance: 5,000-10,000 km. (NEDO)

  19. Results of the freeze resistance test, swelling index and coefficient of permeability of finegrained mining waste reinforced with cements

    Science.gov (United States)

    Morman, Justyna

    2018-04-01

    The article presents the result of laboratory tests for mining waste with grain size of 0 to 2 mm stabilized with cement. Used for stabilization of cement CEM I 42.5 R and blast furnace cement CEM III / A 42.5N - LH / HSR / NA and a plasticizer sealant. Cement was added to the mining waste test in the proportions of 5 - 8% in relation to the skeleton's weight. For the cemented samples, the freeze resistance test, swelling index, coefficient of permeability and pH of water leachate were tested. The addition of a cement binder resulted in diminishing the water permeability of mining waste and limiting the leaching of fine particles from the material.

  20. Influence of test conditions and exposure duration on the result of ecotoxicological tests

    DEFF Research Database (Denmark)

    Rosenkrantz, Rikke Tjørnhøj

    be calculated from results of ecotoxicological tests performed according to internationally approved guidelines, such as from the Organisation for Economic Co-operation and Development (OECD) or International Standardization Organisation (ISO). Such guidelines were originally developed to enable classification...... and hazard ranking of chemicals, and therefore their focus is to measure the toxicity of an artificially maintained continuous exposure under test conditions that rarely reflect natural conditions. This may be in contrast to the aim of establishing EQS, i.e. to protect the natural ecosystem from chemical...... stress. In light of this possible contradiction, the aim of this thesis was to investigate whether EQS derived on the basis of guideline tests will be sufficiently protective of the environment. This was done by exploring the influence of a number of test conditions, such as temperature, light, p...

  1. The Next Generation of High-Speed Dynamic Stability Wind Tunnel Testing (Invited)

    Science.gov (United States)

    Tomek, Deborah M.; Sewall, William G.; Mason, Stan E.; Szchur, Bill W. A.

    2006-01-01

    Throughout industry, accurate measurement and modeling of dynamic derivative data at high-speed conditions has been an ongoing challenge. The expansion of flight envelopes and non-conventional vehicle design has greatly increased the demand for accurate prediction and modeling of vehicle dynamic behavior. With these issues in mind, NASA Langley Research Center (LaRC) embarked on the development and shakedown of a high-speed dynamic stability test technique that addresses the longstanding problem of accurately measuring dynamic derivatives outside the low-speed regime. The new test technique was built upon legacy technology, replacing an antiquated forced oscillation system, and greatly expanding the capabilities beyond classic forced oscillation testing at both low and high speeds. The modern system is capable of providing a snapshot of dynamic behavior over a periodic cycle for varying frequencies, not just a damping derivative term at a single frequency.

  2. Laboratory and Field Test of Movable Conduction-Cooled High-Temperature SMES for Power System Stability Enhancement

    DEFF Research Database (Denmark)

    Fang, Jiakun; Wen, J.; Wang, S.

    2013-01-01

    ’ effectiveness on improvements of system voltage stability and on the oscillation damping. Test results indicate that the SMES system has the features of fast response and four-quadrant power operation. The accessories for the movability of the SEMS system are well designed. The system is feasible to be used...... in power systems.......This paper introduces the first movable conduction-cooled high temperature superconducting magnetic energy storage (SMES) system developed in China. The SMES is rated at 380 V / 35 kJ / 7 kW, consisting of the high temperature magnet confined in a dewar, the cryogenic unit, the converter...

  3. [The effect of prostitution on the stability of romantic relationships. Empirical testing of an evolutionary model].

    Science.gov (United States)

    Meskó, Norbert; Láng, András; Bernáth, László

    2012-01-01

    Until now prostitution has only been explained from two evolutionary points of view. According to the short-term mate choice strategy approach motives for seeking prostitutes are to be found in the nature of male sexuality. Another theory - the evolutionary interpretation of female promiscuity's motivational base - indirectly completes the understanding of prostitution. This theory emphasizes the adaptive benefits of female promiscuity under certain circumstances. The aim of our study was to test a third idea (Adaptive Support Theory), according to which women in long-term relationships support their partners' (husbands') sexual relations with prostitutes. University female students (n=208, age mean±SD=23.55±7.13, min=18, max=50) completed our questionnaire. Female participants are presumed to recognize the advantages and threats of their partners' sexual relations with prostitutes compared to other possible forms of betrayal. Hence it is hypothesized that women overtly support the possibility of their partners' relations with prostitutes. Our results show that women are able to assess the favorable and unfavorable effects of their partners' relations with prostitutes. At the same time they do not directly support this form of betrayal over other possibilities. However, female participants were more approving of their partners' relations with prostitutes (in a thought- experiment), than they guessed their partner would demand such services. According to our model women living in long-term relationship are adaptively interested in their partner's cheating on them with a prostitute (rather than engaging in other kinds of sexual relations), because this finance based external sexual liaison is the least threatening for the stability of the long-term relationship.

  4. Algal growth inhibition test results of 425 organic chemical substances

    DEFF Research Database (Denmark)

    Kusk, Kresten Ole; Christensen, Anne Munch; Nyholm, Niels

    2018-01-01

    values were corrected accordingly. The model helped to identify substances, where the calculated water concentration was too uncertain. Substances covering a wide range of physical-chemical properties and different modes of action were tested. Median effect concentrations (EC50) lower than 1000 mg/L were......The toxicity towards the algal species Pseudokirchneriella subcapitata of 425 organic chemical substances was tested in a growth inhibition test. Precautions were taken to prevent loss of the compounds from the water phase and the test system (closed test system, low biomass, shorter test duration......, silanized glass) and to keep pH constant by applying a higher alkalinity. Chemical phase distribution was modelled taking ionization, volatilisation, and adsorption to glass and biomass into consideration. If the modelled water concentration was below 90% of the nominal concentration the calculated EC...

  5. Plasma Volume Expansion Resulting from Intravenous Glucose Tolerance Test

    Directory of Open Access Journals (Sweden)

    Robert G. Hahn

    2011-01-01

    Full Text Available Objective. To quantify the degree of plasma volume expansion that occurs during an intravenous glucose tolerance test (IVGTT. Methods. Twenty healthy volunteers (mean age, 28 years underwent IVGTTs in which 0.3 g/kg of glucose 30% was injected as a bolus over 1 min. Twelve blood samples were collected over 75 min. The plasma glucose and blood hemoglobin concentrations were used to calculate the volume distribution (Vd and the clearance (CL of both the exogenous glucose and the injected fluid volume. Results. The IVGTT caused a virtually instant plasma volume expansion of 10%. The half-life of the glucose averaged 15 min and the plasma volume expansion 16 min. Correction of the fluid kinetic model for osmotic effects after injection reduced CL for the infused volume by 85%, which illustrates the strength of osmosis in allocating fluid back to the intracellular fluid space. Simulations indicated that plasma volume expansion can be reduced to 60% by increasing the injection time from 1 to 5 min and reducing the glucose load from 0.3 to 0.2 g/kg. Conclusion. A regular IVGTT induced an acute plasma volume expansion that peaked at 10% despite the fact that only 50–80 mL of fluid were administered.

  6. Corrugated Quantum Well Infrared Photodetector Focal Plane Array Test Results

    Science.gov (United States)

    Goldberg, A.; Choi, K. K.; Das, N. C.; La, A.; Jhabvala, M.

    1999-01-01

    The corrugated quantum-well infrared photodetector (C-QWIP) uses total internal reflection to couple normal incident light into the optically active quantum wells. The coupling efficiency has been shown to be relatively independent of the pixel size and wavelength thus making the C-QWIP a candidate for detectors over the entire infrared spectrum. The broadband coupling efficiency of the C-QWIP makes it an ideal candidate for multiwavelength detectors. We fabricated and tested C-QWIP focal plane arrays (FPAs) with cutoff wavelengths of 11.2 and 16.2 micrometers. Each FPA has 256 x 256 pixels that are bump-bonded to a direct injection readout circuit. Both FPAs provided infrared imagery with good aesthetic attributes. For the 11.2-micrometers FPA, background-limited performance (BLIP) was observed at 60 K with f/3 optics. For the 16.2-micrometers FPA, BLIP was observed at 38 K. Besides the reduction of dark current in C-QWIP structures, the measured internal quantum efficiency (eta) remains to be high. The values for responsivity and quantum efficiency obtained from the FPA results agree well with those measured for single devices.

  7. Results from the Cold Atom Laboratory's ground test bed

    Science.gov (United States)

    Elliott, Ethan; CAL Team

    2017-04-01

    We describe validation and development of critical technologies in the Cold Atom Laboratory's (CAL) ground test bed, including the demonstration of the first microwave evaporation and generation of dual-species quantum gas mixtures on an atom chip. CAL is a multi-user facility developed by NASA's Jet Propulsion Laboratory (JPL) to provide the first persistent quantum gas platform in the microgravity environment of space. The CAL instrument will be operated aboard the International Space Station (ISS) and utilize a compact atom chip trap loaded from a dual-species magneto optical trap of rubidium and potassium. In the unique environment of microgravity, the confining potentials necessary to the process of cooling atoms can be arbitrarily relaxed, enabling production of gases down to pikoKelvin temperatures and ultra-low densities. Complete removal of the confining potential allows for ultracold clouds that can float virtually fixed relative to the CAL apparatus. This new parameter regime enables ultracold atom research with broad applications in fundamental physics and inertial sensing. Results from the Cold Atom Laboratory's ground testbed.

  8. MTG infrared sounder detection chain: first radiometric test results

    Science.gov (United States)

    Dumestier, D.; Pistone, F.; Dartois, T.; Blazquez, E.

    2017-11-01

    Europe's next fleet of geostationary meteorological satellites, MeteoSat Third Generation, will introduce new functions in addition to continuity of high-resolution meteorological data. The atmosphere Infrared Sounder (IRS), as high -end instrument, is part of this challenging program. IRS principle is a Fourier Transform Interferometer, which allows recomposing atmospheric spectrum after infrared photons detection. Transmission spectrums will be used to support numerical weather prediction. IRS instrument is able to offer full disk coverage in one hour, an on-ground resolution of 4 by 4 km, in two spectral bands (MWIR: 1600 to 2175cm-1 and LWIR: 700 to 1210cm-1) with a spectral resolution of 0.6cm-1. Among critical technologies and processes, IRS detection chain shall offer outstanding characteristics in terms of radiometric performance like Signal to Noise Ratio (SNR), dynamic range and linearity. Selected detectors are HgCdTe two-dimensions arrays, cooled at 55 Kelvins, hybridized on snapshot silicon read-out circuit at 160x160 format. Video electronics present 16 bits resolution, and the whole detection chain (Detectors and electronics) permits to reach SNR between 2 000 and 10 000 as requested by the application. Radiometric onground test results performed on design representative detection chains are presented and are confirming the challenging phase A design choices.

  9. Lloydminster, Saskatchewan vertical well SAGD field test results

    Energy Technology Data Exchange (ETDEWEB)

    Miller, K.A.; Xiao, Y. [Husky Energy Inc., Calgary, AB (Canada)

    2009-07-01

    Vertical and directional wells have been successfully used at Husky Energy's Pikes Peak Steam Project for cyclic steam stimulation (CSS) and follow-up steam drive in the Waseca channel sand reservoir area inside the oil/water contact. As much as 90 per cent recovery was achieved in some areas using combined CSS and follow-up steam drive. A cumulative steam-to-oil ratio (SOR) of less then 3.0 was also achieved. Similar CSS with follow-up drive methods have not been successful outside the oil/water contact. Some improvement in performance was achieved using large CSS slugs and high steam injection rates. However, in many locations CSS performances were still poor, and conversion from CSS to drive has not been successful in any location. Husky initiated a field test of a single vertical well SAGD configuration in 2008 in an area outside the oil/water contact. The objective was to evaluate an alternate process where the conventional CSS performance of 10 wells was very poor from the second or third stimulation onward. The results revealed that a single vertical well SAGD configuration could be successfully completed and operated. However, the oil production rates and the SOR achieved to date have been unsatisfactory.

  10. Tests of composite materials at cryogenic temperatures facilities and results

    CERN Document Server

    Dahlerup-Petersen, K

    1980-01-01

    The design and installation of test facilities for the determination of macromechanical and thermal properties of fiber-reinforced polymer materials at temperatures down to 4.2K are presented. Construction and performance details are given for the following test equipment: quasi- static-tensile and compression-test facilities equipped with an automatic data acquisition system for calculation of material properties, deformation characteristics and various statistics; a thermal contraction-expansion measuring system; a thermal conductivity measurement cell. (1 refs).

  11. Final report on special impact tests of plutonium shipping containers description of test results

    International Nuclear Information System (INIS)

    Bonzon, L.L.

    1977-02-01

    The results from tests conducted to determine the structural response of the LLD-1, Model 1518-6M, and FL-10 plutonium shipping packages when subjected to high-speed impacts (170 to 760 ft/sec) onto unyielding, concrete, and soil targets are presented

  12. Short-term stability test for thorium soil candidate a reference material

    International Nuclear Information System (INIS)

    Clain, Almir F.; Fonseca, Adelaide M.G.; Dantas, Vanessa V.D.B.; Braganca, Maura J.C.; Souza, Poliana S.

    2015-01-01

    This work describes a methodology to determine the soil short-term stability after the steps of production in laboratory. The short-term stability of the soil is an essential property to be determined in order to producing a reference material. The soil is a candidate of reference material for chemical analysis of thorium with metrological traceability to be used in environmental analysis, equipment calibration, validation methods, and quality control. A material is considered stable in a certain temperature if the property of interest does not change with time, considering the analytical random fluctuations. Due to this, the angular coefficient from the graphic of Th concentration versus elapsed time must be near to zero. The analytical determinations of thorium concentration were performed by Instrumental Neutron activation Analysis. The slopes and their uncertainties were obtained from the regression lines at temperatures of 20 deg C and 60 deg C, with control temperature of -20 deg C. From the obtained data a t-test was applied. In both temperatures the calculated t-value was lower than the critical value, so we can conclude with 95% confidence level that no significant changes happened during the period studied concerning thorium concentration in soil at temperatures of 20 deg C and 60 deg C, showing stability at these temperatures. (author)

  13. Preliminary irradiation test results from the Yankee Atomic Electric Company reactor vessel test irradiation program

    International Nuclear Information System (INIS)

    Biemiller, E.C.; Fyfitch, S.; Campbell, C.A.

    1993-01-01

    The Yankee Atomic Electric Company test irradiation program was implemented to characterize the irradiation response of representative Yankee Rowe reactor vessel beltline plate materials and to remove uncertainties in the analysis of existing irradiation data on the Yankee Rowe reactor vessel steel. Plate materials each containing 0.24 w/o copper, but different nickel contents at 0.63 w/o and 0.19 w/o, were heat treated to simulate the Yankee vessel heat treatment (austenitized at 1800 deg F) and to simulate Regulatory Guide 1.99 database materials (austenitized at 1600 deg. F). These heat treatments produced different microstructures so the effect of microstructure on irradiation damage sensitivity could be tested. Because the nickel content of the test plates varied and the copper level was constant, the effect of nickel on irradiation embrittlement was also tested. Correlation monitor material, HSST-02, was included in the program to benchmark the Ford Nuclear Reactor (U. of Michigan Test Reactor) which had never been used for this type of irradiation program. Materials taken from plate surface locations (vs. 1/4T) were included to test whether or not the improved toughness properties of the plate surface layer, resulting from the rapid quench, is maintained after irradiation. If the improved properties are maintained, pressurized thermal shock calculations could utilize this margin. Finally, for one experiment, irradiations were conducted at two irradiation temperatures (500 deg. F and 550 deg. F) to determine the effect of irradiation temperature on embrittlement. The preliminary results of the irradiation program show an increase in T 30 shift of 69 deg. F for a decrease in irradiation temperature of 50 deg. F. The results suggest that for nickel bearing steels, the superior toughness of plate surface material is maintained after irradiation and for the copper content tested, nickel had no apparent effect on irradiation response. No apparent microstructure

  14. Li-Ion Cell Lot Testing and Flight Screening Results

    Science.gov (United States)

    2011-02-01

    This document reports the lot characterization and sample testing required for certification of a new lot of Moli-Energy Li-lon ICR-18650H 2200-mAh...cells that constitute this new lot are also presented. All testing began upon receipt of the new cell lot in March 2(K)9 and was performed with the

  15. Cone Penetrometer Load Cell Temperature and Radiation Testing Results

    Energy Technology Data Exchange (ETDEWEB)

    Follett, Jordan R.

    2013-08-28

    This report summarizes testing activities performed at the Pacific Northwest National Laboratory to verify the cone penetrometer load cell can withstand the tank conditions present in 241-AN-101 and 241-AN-106. The tests demonstrated the load cell device will operate under the elevated temperature and radiation levels expected to be encountered during tank farm deployment of the device.

  16. HIPPARCOS satellite: Aeritalia involvement and system test activities and results

    Science.gov (United States)

    Strim, B.; Cugno, W.; Morsillo, G.

    when observed from two different points, for example, from two different points in the Earth's orbit around the sun. Distance can be calculated using parallax measurements). The satellite payload is a Schmidt reflecting telescope with two openings 58 degrees apart. The design allows stars in two different parts of the sky to be observed at the same time. Internally, the two fields of view are combined and the angular separation between pairs of stars - one star from each field of view - is recorded. Over the 2.5-year life of the HIPPARCOS mission, millions of such measurements between star pairs as faint as magnitude 13 will be made covering the entire celestial sphere. The data will be compiled into the HIPPARCOS catalog. The accuracy of these measurements for most of the stars is expected to be within 0.002 arcsec, an improvement of about a factor of 20 over ground-based observations. A second experiment, called TYCHO, will collect position and photometric data on about 400.000 stars. Although less accurate than the main experiment, TYCHO will provide astronomers with a reference catalog for a large number of stars. Both the HIPPARCOS and TYCHO star catalogs are expected to be available to the worldwide astronomical community by around 1994. The launch weight of HIPPORCOS is 1.140 kg. It will be put into geostationary orbit by an Ariane rocket. Purpose of the present paper is to put the spotlight on the system tests performed on the Satellite Structural Thermal Model STM, the Engineering Model EM and to summarize the main results so far obtained. A description of the System and Spacecraft design to better understand the mission and system requirements is also presented.

  17. Results of thermal test of metallic molybdenum disk target and fast-acting valve testing

    Energy Technology Data Exchange (ETDEWEB)

    Virgo, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Chemerisov, S. [Argonne National Lab. (ANL), Argonne, IL (United States); Gromov, R. [Argonne National Lab. (ANL), Argonne, IL (United States); Jonah, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Vandegrift, G. F. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-12-01

    This report describes the irradiation conditions for thermal testing of helium-cooled metallic disk targets that was conducted on March 9, 2016, at the Argonne National Laboratory electron linac. The four disks in this irradiation were pressed and sintered by Oak Ridge National Laboratory from molybdenum metal powder. Two of those disks were instrumented with thermocouples. Also reported are results of testing a fast-acting-valve system, which was designed to protect the accelerator in case of a target-window failure.

  18. Thermal-Chemical Model Of Subduction: Results And Tests

    Science.gov (United States)

    Gorczyk, W.; Gerya, T. V.; Connolly, J. A.; Yuen, D. A.; Rudolph, M.

    2005-12-01

    Seismic structures with strong positive and negative velocity anomalies in the mantle wedge above subduction zones have been interpreted as thermally and/or chemically induced phenomena. We have developed a thermal-chemical model of subduction, which constrains the dynamics of seismic velocity structure beneath volcanic arcs. Our simulations have been calculated over a finite-difference grid with (201×101) to (201×401) regularly spaced Eulerian points, using 0.5 million to 10 billion markers. The model couples numerical thermo-mechanical solution with Gibbs energy minimization to investigate the dynamic behavior of partially molten upwellings from slabs (cold plumes) and structures associated with their development. The model demonstrates two chemically distinct types of plumes (mixed and unmixed), and various rigid body rotation phenomena in the wedge (subduction wheel, fore-arc spin, wedge pin-ball). These thermal-chemical features strongly perturb seismic structure. Their occurrence is dependent on the age of subducting slab and the rate of subduction.The model has been validated through a series of test cases and its results are consistent with a variety of geological and geophysical data. In contrast to models that attribute a purely thermal origin for mantle wedge seismic anomalies, the thermal-chemical model is able to simulate the strong variations of seismic velocity existing beneath volcanic arcs which are associated with development of cold plumes. In particular, molten regions that form beneath volcanic arcs as a consequence of vigorous cold wet plumes are manifest by > 20% variations in the local Poisson ratio, as compared to variations of ~ 2% expected as a consequence of temperature variation within the mantle wedge.

  19. Test results and commercialization plans for long life Stirling generators

    International Nuclear Information System (INIS)

    Erbeznik, R.M.; White, M.A.

    1996-01-01

    Many optimistic predictions regarding commercialization of Stirling engines have been announced over the years, but to date no real successes have emerged. STC is excited to announce the availability of beta prototypes for its RemoteGen trademark family of free-piston Stirling generators. STC is working with suppliers, manufacturers, and beta customers to commercialize the RemoteGen family of generators. STC is proving that these machines overcome previously inhibiting barriers by providing long life, high reliability, cost effective mass production, and market relevance. Stirling power generators are generally acknowledged to offer much higher conversion efficiencies than direct energy conversion systems. Life and reliability, on the other hand, are generally considered superior for direct conversion systems, as established by the exceptional endurance records (though with degradation) for thermoelectric (TE) and photovoltaic (PV) systems. STC's unique approaches combine dynamic system efficiency with static system reliability. The RemoteGen family presently includes a 10-watt RG-10, a 350-watt RG-350, and with 1-kW and 3-kW sizes planned for the future. They all use the same basic configuration with flexure bearings, clearance seals, and moving iron linear alternators. The third generation RG-10 has entered limited production with a radioisotope-fueled version, and a niche market for a propane-fueled version has been identified. Market analysis has led STC to focus on early commercial production of the RG-350. The linear alternator power module portion of the RG-350 is also used in its sister BeCool trademark family of coolers as the linear motor. By using a common power module, both programs will benefit by each other's commercialization efforts. The technology behind the RemoteGen generators, test results, and plans for commercialization are described in this paper

  20. The IEA large coil task test results in IFSMTF

    International Nuclear Information System (INIS)

    Lubell, M.S.; Clinard, J.A.; Dresner, L.

    1987-01-01

    The Large Coil Task (LCT) is an international collaboration of the United States, EURATOM, Japan, and Switzerland to develop large superconducting magnets for fusion reactors. The testing phase of LCT was completed on September 3, 1987. All six coils exceeded the design goals, both as single coils and in six-coil toroidal tests. In addition, a symmetric torus test was performed in which a maximum field of 9 T was reached in all coils simultaneously. These are by far the largest magnets (either in size, weight, or stored energy) ever to achieve such a field. 6 refs., 6 figs., 3 tabs

  1. Reference markers in computer aided orthopaedic surgery: rotational stability testings and clinical implications.

    Science.gov (United States)

    Kendoff, Daniel; Gardner, Michael J; Krettek, Christian; Hüfner, Tobias; Citak, Musa

    2008-06-01

    Navigation procedures rely on the stability of the reference arrays (RA) fixed to the bony anatomy. The risk of inadvertent collision and unnoticed movements of the RA may occur, and limb movements might also provocate collisions. Consequently, relevant measurements failures during the navigated procedure might occur and reduce the overall precision of the system. The magnitude of torque to destabilize an RA from its bony-fixation is unknown. The purpose of this study was to determine the ability of standard RA's to resist applied torque. A digital torque application device was developed to allow for precise torque application to the RA system at four cadavers. Clockwise, gradually increasing rotational force was applied to the RA in 1, 2, or 3 Nm, held for 1 s and released, repeated in 10 cycles. One pin fixation systems with 4.0 Schanz pins were used. A second RA was fixed 20 cm proximal to the tested RA. A navigation system was used to measure the relative positions of both RA's during torque application. The rotational differences at torque application were calculated and statistically evaluated. Results revealed averaged 1.0 degrees rotation [range (r), 1.0-1.1 degrees ] with first cycle of 1 Nm torque, the last cycle averaged 1.0 degrees (r, 1.0-1.1 degrees ) with no significant differences in rotation between any of the cycles (p > 0.5). Torque of 2 Nm resulted in 1.8 degrees rotation (r, 1.5-1.8 degrees ) with no significant increases between first and second cycle (p = 0.56), second and third trials (p = 0.35) while fourth cycle averaged 2.0 degrees , with significant increase (p = 0.011). All subsequent cycles resulted in significant increases. Torque of 3 Nm produced 2.9 degrees of rotation for initial cycle (r,2.5-3.3 degrees ), with significant increases with each cycle (p or =2 Nm may cause loosening of the RA, thus may lose its original position relative to the bone. Surgeons using computer aided surgery systems should be aware of possible

  2. Battery cycling and calendar aging: year one testing results.

    Science.gov (United States)

    2016-07-01

    This report is meant to provide an update on the ongoing battery testing performed by the Hawaii Natural Energy Institute to evaluate Electric Vehicle (EV) battery durability and reliability under electric utility grid operations. Commercial EV batte...

  3. CHALLENGE TESTS WITH LISTERIA MONOCYTOGENES IN SALAMI: PRELIMINARY RESULTS

    Directory of Open Access Journals (Sweden)

    R. Mioni

    2013-02-01

    Full Text Available Challenge tests are the preferable methodology to study the behaviour of Listeria monocytogenes on ready to eat foods, according to Regulation (EC 2073/2005. Challenge testing using L. monocytogenes in seasoned salami from different food business operators showed, after seasoning of the product, a count reduction of the inoculated organisms without any further growth of the pathogen; however differences of L. monocytogenes behaviour could be observed according to different production protocols.

  4. SLAC FASTBUS Snoop Module: test results and support software

    International Nuclear Information System (INIS)

    Gustavson, D.B.; Walz, H.V.

    1985-09-01

    The development of a diagnostic module for FASTBUS has been completed. The Snoop Module is designed to reside on a Crate Segment and provide high-speed diagnostic monitoring and testing capabilities. Final hardware details and testing of production prototype modules are reported. Features of software under development for a stand-alone single Snoop diagnostic system and Multi-Snoop networks will be discussed. 3 refs., 2 figs

  5. SIMS prototype system 1 test results: Engineering analysis

    Science.gov (United States)

    1978-01-01

    The space and domestic water solar heating system designated SIMS Prototype Systems 1 was evaluated. The test system used 720 ft (gross) of Solar Energy Products Air Collectors, a Solar Control Corporation SAM 20 Air Handler with Model 75-175 control unit, a Jackson Solar Storage tank with Rho Sigma Mod 106 controller, and 20 tons of rack storage. The test data analysis performed evaluates the system performance and documents the suitability of SIMS Prototype System 1 hardware for field installation.

  6. A result concerning the stability of some difference equations and its ...

    Indian Academy of Sciences (India)

    M. Senthilkumar (Newgen Imaging) 1461 1996 Oct 15 13:05:22

    , Ulam [18] raised a question concerning the stability of group homomorphisms: Let G1 be a group and let G2 be a metric group with the metric d(·, ·). Given ε > 0, does there exist a δ > 0 such that if a function h : G1 → G2 satisfies the inequality.

  7. stability results of a mathematical model for the control of hiv/aids ...

    African Journals Online (AJOL)

    DJFLEX

    Subthreshold Domain of Bistable Equilibria for a Model of. HIV Epidemiology. International Journal of Mathematics and Mathematical Sciences, 58, 3679-3698. David R. M., 1997. Introduction to Theory of Stability. Springer-Verlag, New York, Inc. USA. Family Health International, 2007. How the Female Condom Affects Male ...

  8. Ternary conjugates as a result of exchange reactions between polyelectrolyte complexes and surfactants: Formation and stability

    Czech Academy of Sciences Publication Activity Database

    Zintchenko, A.; Koňák, Čestmír

    2004-01-01

    Roč. 205, č. 15 (2004), s. 1979-1986 ISSN 1022-1352 R&D Projects: GA AV ČR IAA4050403 Keywords : colloid stability * drug delivery systems * light scattering Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.880, year: 2004

  9. A result concerning the stability of some difference equations and its ...

    Indian Academy of Sciences (India)

    M. Senthilkumar (Newgen Imaging) 1461 1996 Oct 15 13:05:22

    Ulam stability problem for eq. (1.1). That is, the difference equation (1.1) is stable in the sense of Hyers and Ulam under the conditions subject to. (2.1) and (2.2). Theorem 2.1. Suppose that functions f, ψ : N × N → R and ϕ satisfy the inequality.

  10. On personality stability and change: main results of Brno longitudinal study on life-span development

    Czech Academy of Sciences Publication Activity Database

    Blatný, Marek

    2007-01-01

    Roč. 51, Supplement (2007), s. 37-49 ISSN 0009-062X R&D Projects: GA ČR(CZ) GA406/06/1408 Institutional research plan: CEZ:AV0Z70250504 Keywords : life-span development * personality stability and change Subject RIV: AN - Psychology Impact factor: 0.133, year: 2007

  11. Post-test investigation result on the WWER-1000 fuel tested under severe accident conditions

    International Nuclear Information System (INIS)

    Goryachev, A.; Shtuckert, Yu.; Zwir, E.; Stupina, L.

    1996-01-01

    The model bundle of WWER-type were tested under SFD condition in the out-of-pile CORA installation. The objective of the test was to provide an information on the WWER-type fuel bundles behaviour under severe fuel damage accident conditions. Also it was assumed to compare the WWER-type bundle damage mechanisms with these experienced in the PWR-type bundle tests with aim to confirm a possibility to use the various code systems, worked our for PWR as applied to WWER. In order to ensure the possibility of the comparison of the calculated core degradation parameters with the real state of the tested bundle, some parameters have been measured on the bundle cross-sections under examination. Quantitative parameters of the bundle degradation have been evaluated by digital image processing of the bundle cross-sections. The obtained results are shown together with corresponding results obtained by the other participants of this investigation. (author). 3 refs, 13 figs

  12. Testing Single and Combinations of Amendments for Stabilization of Metals in Contrasting Extremely Contaminated Soils

    Directory of Open Access Journals (Sweden)

    Siebielec G.

    2013-04-01

    Full Text Available Metals can be stabilized by soil amendments that increase metals adsorption or alter their chemical forms. Such treatments may limit the risk related to the contamination through reduction of metal transfer to the food chain (reduction of metal uptake by plants and its availability to soil organisms and metals migration within the environment. There is a need for experiments comparing various soil amendments available at reasonable amounts under similar environmental conditions. The other question is whether all components of soil environment or soil functions are similarly protected after remediation treatment. We conducted a series of pot studies to test some traditional and novel amendments and their combinations. The treatments were tested for several highly Zn/Cd/Pb contaminated soils. Among traditional amendments composts were the most effective – they ensured plant growth, increased soil microbial activity, reduced Cd in earthworms, reduced Pb bioaccessibility and increased share of unavailable forms of Cd and Pb.

  13. Treatability Test Plan for 300 Area Uranium Stabilization through Polyphosphate Injection

    Energy Technology Data Exchange (ETDEWEB)

    Vermeul, Vincent R.; Williams, Mark D.; Fritz, Brad G.; Mackley, Rob D.; Mendoza, Donaldo P.; Newcomer, Darrell R.; Rockhold, Mark L.; Williams, Bruce A.; Wellman, Dawn M.

    2007-06-01

    The U.S. Department of Energy has initiated a study into possible options for stabilizing uranium at the 300 Area using polyphosphate injection. As part of this effort, PNNL will perform bench- and field-scale treatability testing designed to evaluate the efficacy of using polyphosphate injections to reduced uranium concentrations in the groundwater to meet drinking water standards (30 ug/L) in situ. This technology works by forming phosphate minerals (autunite and apatite) in the aquifer that directly sequester the existing aqueous uranium in autunite minerals and precipitates apatite minerals for sorption and long term treatment of uranium migrating into the treatment zone, thus reducing current and future aqueous uranium concentrations. Polyphosphate injection was selected for testing based on technology screening as part of the 300-FF-5 Phase III Feasibility Study for treatment of uranium in the 300-Area.

  14. Fisher matrix forecasts for astrophysical tests of the stability of the fine-structure constant

    Directory of Open Access Journals (Sweden)

    C.S. Alves

    2017-07-01

    Full Text Available We use Fisher Matrix analysis techniques to forecast the cosmological impact of astrophysical tests of the stability of the fine-structure constant to be carried out by the forthcoming ESPRESSO spectrograph at the VLT (due for commissioning in late 2017, as well by the planned high-resolution spectrograph (currently in Phase A for the European Extremely Large Telescope. Assuming a fiducial model without α variations, we show that ESPRESSO can improve current bounds on the Eötvös parameter—which quantifies Weak Equivalence Principle violations—by up to two orders of magnitude, leading to stronger bounds than those expected from the ongoing tests with the MICROSCOPE satellite, while constraints from the E-ELT should be competitive with those of the proposed STEP satellite. Should an α variation be detected, these measurements will further constrain cosmological parameters, being particularly sensitive to the dynamics of dark energy.

  15. Experimental test of theory for the stability of partially saturated vertical cut slopes

    Science.gov (United States)

    Morse, Michael M.; Lu, N.; Wayllace, Alexandra; Godt, Jonathan W.; Take, W.A.

    2014-01-01

    This paper extends Culmann's vertical-cut analysis to unsaturated soils. To test the extended theory, unsaturated sand was compacted to a uniform porosity and moisture content in a laboratory apparatus. A sliding door that extended the height of the free face of the slope was lowered until the vertical cut failed. Digital images of the slope cross section and upper surface were acquired concurrently. A recently developed particle image velocimetry (PIV) tool was used to quantify soil displacement. The PIV analysis showed strain localization at varying distances from the sliding door prior to failure. The areas of localized strain were coincident with the location of the slope crest after failure. Shear-strength and soil-water-characteristic parameters of the sand were independently tested for use in extended analyses of the vertical-cut stability and of the failure plane angle. Experimental failure heights were within 22.3% of the heights predicted using the extended theory.

  16. Hunter standoff killer team (HSKT) ground and flight test results

    Science.gov (United States)

    Moreland, Balinda; Ennis, Mark; Yeates, Robert; Condon, Timothy

    2007-04-01

    Warfighter's Associate (WA) which was integrated onto the Apache Longbow, and the Mobile Commanders Associate (MCA) which was integrated onto the Army Airborne Command and Control System (A2C2S) UH-60 Blackhawk. In this paper we will discuss what WA and MCA provided to the warfighter, and the results of the HSKT ground and flight testing.

  17. How many trials are needed to achieve performance stability of the Timed Up & Go test in patients with hip fracture?

    DEFF Research Database (Denmark)

    Kristensen, Morten T; Ekdahl, Charlotte; Kehlet, Henrik

    2010-01-01

    To examine the number of trials needed to achieve performance stability of the Timed Up & Go (TUG) test using a standardized walking aid in patients with hip fracture who are allowed full weight bearing (FWB).......To examine the number of trials needed to achieve performance stability of the Timed Up & Go (TUG) test using a standardized walking aid in patients with hip fracture who are allowed full weight bearing (FWB)....

  18. Acquisition of Co metal from spent lithium-ion battery using emulsion liquid membrane technology and emulsion stability test

    Science.gov (United States)

    Yuliusman; Wulandari, P. T.; Amiliana, R. A.; Huda, M.; Kusumadewi, F. A.

    2018-03-01

    Lithium-ion batteries are the most common type to be used as energy source in mobile phone. The amount of lithium-ion battery wastes is approximated by 200 – 500 ton/year. In one lithium-ion battery, there are 5 – 20% of cobalt metal, depend on the manufacturer. One of the way to recover a valuable metal from waste is leaching process then continued with extraction, which is the aim of this study. Spent lithium-ion batteries will be characterized with EDX and AAS, the result will show the amount of cobalt metal with form of LiCoO2 in the cathode. Hydrochloric acid concentration used is 4 M, temperature 80°C, and reaction time 1 hour. This study will discuss the emulsion stability test on emulsion liquid membrane. The purpose of emulsion stability test in this study was to determine optimum concentration of surfactant and extractant to produce a stable emulsion. Surfactant and extractant used were SPAN 80 and Cyanex 272 respectively with both concentrations varied. Membrane and feed phase ratios used in this experiment was 1 : 2. The optimum results of this study were SPAN 80 concentrations of 10% w/v and Cyanex 272 0.7 M.

  19. Results from Carbon Dioxide Washout Testing Using a Suited Manikin Test Apparatus with a Space Suit Ventilation Test Loop

    Science.gov (United States)

    Chullen, Cinda; Conger, Bruce; McMillin, Summer; Vonau, Walt; Kanne, Bryan; Korona, Adam; Swickrath, Mike

    2016-01-01

    NASA is developing an advanced portable life support system (PLSS) to meet the needs of a new NASA advanced space suit. The PLSS is one of the most critical aspects of the space suit providing the necessary oxygen, ventilation, and thermal protection for an astronaut performing a spacewalk. The ventilation subsystem in the PLSS must provide sufficient carbon dioxide (CO2) removal and ensure that the CO2 is washed away from the oronasal region of the astronaut. CO2 washout is a term used to describe the mechanism by which CO2 levels are controlled within the helmet to limit the concentration of CO2 inhaled by the astronaut. Accumulation of CO2 in the helmet or throughout the ventilation loop could cause the suited astronaut to experience hypercapnia (excessive carbon dioxide in the blood). A suited manikin test apparatus (SMTA) integrated with a space suit ventilation test loop was designed, developed, and assembled at NASA in order to experimentally validate adequate CO2 removal throughout the PLSS ventilation subsystem and to quantify CO2 washout performance under various conditions. The test results from this integrated system will be used to validate analytical models and augment human testing. This paper presents the system integration of the PLSS ventilation test loop with the SMTA including the newly developed regenerative Rapid Cycle Amine component used for CO2 removal and tidal breathing capability to emulate the human. The testing and analytical results of the integrated system are presented along with future work.

  20. Using GPS to determine vehicle attitude - USS Yorktown test results

    Science.gov (United States)

    Kruczynski, Leonard R.; Li, Pui C.; Evans, Alan G.; Hermann, Bruce R.

    Prototype GPS orientation equipment was tested aboard the USS Yorktown, a U.S. Navy guided missile cruiser, to demonstrate that GPS could be used to determine orientation on a moving vessel. Initialization, integer maintenance, and accuracy in a real-time dynamic environment were addressed. The tests confirmed GPS-based real-time orientation determination, provided real-world data to exercise enhanced orientation algorithms, and identified equipment improvements that will make GPS a viable source of vehicle attitude in addition to GPS's superior positioning capabilities.

  1. Performance of CREAM Calorimeter Results of Beam Tests

    CERN Document Server

    Ahn, H S; Beatty, J J; Bigongiari, G; Castellina, A; Childers, J T; Conklin, N B; Coutu, S; Duvernois, M A; Ganel, O; Han, J H; Hyun, H J; Kang, T G; Kim, H J; Kim, K C; Kim, M Y; Kim, T; Kim, Y J; Lee, J K; Lee, M H; Lutz, L; Maestro, P; Malinine, A; Marrocchesi, P S; Mognet, S I; Nam, S W; Nutter, S; Park, N H; Park, H; Seo, E S; Sina, R; Syed, S; Song, C; Swordy, S; Wu, J; Yang, J; Zhang, H Q; Zei, R; Zinn, S Y

    2005-01-01

    The Cosmic Ray Energetics And Mass (CREAM), a balloon-borne experiment, is under preparation for a flight in Antarctica at the end of 2004. CREAM is planned to measure the energy spectrum and composition of cosmic rays directly at energies between 1 TeV and 1000 TeV. Incident particle energies will be measured by a transition radiation detector and a sampling calorimeter. The calorimeter was constructed at the University of Maryland and tested at CERN in 2003. Performance of the calorimeter during the beam tests is reported.

  2. Linking soil permeability and soil aggregate stability with root development: a pots experiment (preliminary results)

    Science.gov (United States)

    Vergani, Chiara; Graf, Frank; Gerber, Werner

    2015-04-01

    Quantifying and monitoring the contribution of vegetation to the stability of the slopes is a key issue for implementing effective soil bioengineering measures. This topic is being widely investigated both from the hydrological and mechanical point of view. Nevertheless, due to the high variability of the biological components, we are still far from a comprehensive understanding of the role of plants in slope stabilization, especially if the different succession phases and the temporal development of vegetation is considered. Graf et al., 2014, found within the scope of aggregate stability investigations that the root length per soil volume of alder specimen grown for 20 weeks under laboratory conditions is comparable to the one of 20 years old vegetation in the field. This means that already relatively short time scales can provide meaningful information at least for the first stage of colonization of soil bioengineering measures, which is also the most critical. In the present study we analyzed the effect of root growth on two soil properties critical to evaluate the performance of vegetation in restoring and re-stabilizing slopes: permeability and soil aggregate stability. We set up a laboratory experiment in order to work under controlled conditions and limit as much as possible the natural variability. Alnus incana was selected as the study species as it is widely used in restoration projects in the Alps, also because of its capacity to fix nitrogen and its symbiosis with both ecto and arbuscular mycorrhizal fungi. After the first month of growth in germination pots, we planted one specimen each in big quasi cylindrical pots of 34 cm diameter and 35 cm height. The pots were filled with the soil fraction smaller than 10 mm coming from an oven dried moraine collected in a subalpine landslide area (Hexenrübi catchment, central Switzerland). The targeted dry unit weight was 16 kN/m3. The plants have been maintained at a daily temperature of 25°C and relative

  3. Preliminary irradiation test results from the Yankee Atomic Electric Company reactor vessel test irradiation program

    International Nuclear Information System (INIS)

    Biemiller, E.C.; Fyfitch, Stephen; Campbell, C.A.

    1994-01-01

    The Yankee Atomic Electric Company test irradiation program was implemented to characterize the irradiation response of representative Yankee Rowe reactor vessel beltline plate materials and to remove uncertainties in the analysis of existing irradiation data on the Yankee Rowe reactor vessel steel. Plate materials each containing 0.24 w/o copper, but different nickel contents at 0.63 w/o and 0.19 w/o, were heat treated to simulate the Yankee vessel heat treatment (austenitized at 982 o C (1800 o F)) and to simulate Regulatory Guide 1.99 database materials (austenitized at 871 o C (1600 o F)). These heat treatments produced different microstructures so the effect of microstructure on irradiation damage sensitivity could be tested. Because the nickel content of the test plates varied and the copper level was constant, the effect of nickel on irradiation embrittlement was also tested. Correlation monitor material, HSST-02, was included in the program to benchmark the Ford Nuclear Reactor (University of Michigan Test Reactor) which had never been used before for this type of irradiation program. Materials taken from plate surface locations (versus 1/4 T) were included to test whether or not the improved toughness properties of the plate surface layer, resulting from the rapid quench, are maintained after irradiation. If the improved properties are maintained, pressurized thermal shock calculations could utilize this margin. Finally, for one experiment, irradiations were conducted at two irradiation temperatures (260 o C and 288 o C) to determine the effect of irradiation temperature on embrittlement. (Author)

  4. Designs and test results for three new rotational sensors

    Czech Academy of Sciences Publication Activity Database

    Jedlička, Petr; Kozák, Jan; Evans, J. R.; Hutt, C. R.

    2012-01-01

    Roč. 16, č. 4 (2012), s. 639-647 ISSN 1383-4649 R&D Projects: GA MŠk(CZ) ME10008 Institutional research plan: CEZ:AV0Z30120515 Keywords : rotational seismology * seismometry * instrument testing * instrument design Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 1.388, year: 2012

  5. The Mark III vertex chamber and prototype test results

    International Nuclear Information System (INIS)

    Grab, C.

    1987-07-01

    A vertex chamber has been constructed for use in the Mark III experiment. The chamber is positioned inside the current main drift chamber and will be used to trigger data collection, to aid in vertex reconstruction, and to improve the momentum resolution. This paper discusses the chamber's construction and performance and tests of the prototype

  6. Acquired intolerance to organic solvents and results of vestibular testing

    Energy Technology Data Exchange (ETDEWEB)

    Gyntelberg, F.; Vesterhauge, S.; Fog, P.; Isager, H.; Zillstorff, K.

    1986-01-01

    Among 160 consecutive patients referred to the Clinic of Occupational Medicine, Rigshospitalet, for symptoms connected with exposure to organic solvents, 20 exhibited symptoms of acquired intolerance to minor amounts of organic solvents. Later, an additional 30 consecutive patients with symptoms of acquired intolerance were included, yielding a total of 43 men and 7 women. The characteristics of the clinical syndrome described are complaints of dizziness, nausea, and weakness after exposure to minimal solvent vapor concentrations. After having tolerated long-term occupational exposure to moderate or high air concentrations of various organic solvents, the patients became intolerant within a short period of time. Since dizziness was a frequent complaint, we tried to obtain a measure of the patients' complaints using vestibular tests. As a diagnostic test the combined vestibular tests had a sensitivity of 0.55 and a specificity of 0.87. No differences between patients with and without intolerance could be detected by the vestibular tests used. We conclude that acquired intolerance to organic solvents is a new but characteristic and easily recognizable syndrome, often with severe consequences for the patient's working ability.

  7. Aggregating Polytomous DIF Results over Multiple Test Administrations

    Science.gov (United States)

    Zwick, Rebecca; Ye, Lei; Isham, Steven

    2018-01-01

    In typical differential item functioning (DIF) assessments, an item's DIF status is not influenced by its status in previous test administrations. An item that has shown DIF at multiple administrations may be treated the same way as an item that has shown DIF in only the most recent administration. Therefore, much useful information about the…

  8. Results of Laboratory Testing of Advanced Power Strips

    Energy Technology Data Exchange (ETDEWEB)

    Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-08-01

    Presented at the ACEEE Summer Study on Energy Efficiency in Buildings on August 12-17, 2012, this presentation reports on laboratory tests of 20 currently available advanced power strip products, which reduce wasteful electricity use of miscellaneous electric loads in buildings.

  9. TEST RESULTS FOR FUEL CELL OPERATION ON ANAEROBIC DIGESTER GAS

    Science.gov (United States)

    EPA, in conjunction with ONSI Corp., embarked on a project to define, design, test, and assess a fuel cell energy recovery system for application at anaerobic digester waste water (sewage) treatment plants. Anaerobic digester gas (ADG) is produced at these plants during the proce...

  10. Results of Caisson Breakwater Tests in Multidirectional Breaking Seas

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter

    In extension of the work done at the Hydraulics and Coastal Engineering Laboratory, Dept. of Civil Engineering, Aalborg University, Denmark, described in Grønbech et al., 1997, laboratory tests has been performed investigating wave loading and overtopping on caisson breakwaters in multidirectional...

  11. Preliminary test results for analogy experiment methodology developments

    International Nuclear Information System (INIS)

    Ko, Sang Hyuk; Chung, Bum Jin

    2005-01-01

    Expanded use of hydrogen as an energy carrier could help address concerns about global climate change and energy security. Hydrogen can be derived from a variety of domestically available primary sources such as fossil fuels, renewables, and nuclear power. The idea of hydrogen production by using the heat from nuclear power, HTGR (High-Temperature Gas-cooled Reactor), seems to be promising. The knowledge of detailed heat transfer phenomena in gaseous phase emerges as an important factor for HTGR, where buoyancy force plays a significant role. Large and expensive test facilities are to be constructed to assess the detailed mixed convection phenomena. However, using the analogy concept, a simple and cheap test facility could replace those. This study explores the feasibility of the idea

  12. Results of experiments in the THIBO II test section

    International Nuclear Information System (INIS)

    Bojarsky, E.; Deckers, H.; Lehning, H.; Piel, D.; Reiser, H.; Schmidt, L.

    1989-10-01

    It was possible to prove in 1988 in the course of the THIBO I experiments; that under certain operating conditions thermohydraulically induced rod damaging oscillations may occur in sodium cooled Mark II fuel elements. Since May 1989 another THIBO II test series has been performed in a new test section of the sodium loop of the IMF III. The area of the coolant channel was reduced to approximately half its previous surface so that the thermohydraulic conditions come very close to those prevailing in the KNK II reactor. The experiments have shown that even with minor sodium enthalpy raises and low rating, respectively, motions of the fuel pins can be induced. This applies also in cases where the clearance of the pin in the spacer has been set to realistically low values

  13. Results from the average power laser experiment photocathode injector test

    International Nuclear Information System (INIS)

    Dowell, D.H.; Bethel, S.Z.; Friddell, K.D.

    1995-01-01

    Tests of the electron beam injector for the Boeing/Los Alamos Average Power Laser Experiment (APLE) have demonstrated first time operation of a photocathode RF gun accelerator at 25% duty factor. This exceeds previous photocathode operation by three orders of magnitude. The success of these tests was dependent upon the development of reliable and efficient photocathode preparation and processing. This paper describes the fabrication details for photocathodes with quantum efficiencies up to 12% which were used during electron beam operation. Measurements of photocathode lifetime as it depends upon the presence of water vapor are also presented. Observations of photocathode quantum efficiency rejuvenation and extended lifetime in the RF cavities are described. The importance of these effects upon photocathode lifetime during high average power operation are discussed. ((orig.))

  14. Test beam results of LHCb scintillating fibre tracker prototypes

    Energy Technology Data Exchange (ETDEWEB)

    Bachmann, Sebastian; Comerma, Albert; Gerick, David; Hansmann-Menzemer, Stephanie; Kecke, Matthieu; Leverington, Blake; Mazorra de Cos, Jose; Mitzel, Dominik; Neuner, Max; Uwer, Ulrich; Han, Xiaoxue [Physikalisches Institut, Universitaet Heidelberg (Germany); Collaboration: LHCb-Collaboration

    2016-07-01

    During the Long Shutdown 2 of the LHC, the LHCb detector will undergo a major upgrade to meet the challenges of running at a higher luminosity. The current Inner and Outer Tracking system will not be sufficient to deal with the envisaged increased detector occupancy and higher radiation levels and will be replaced by a single tracking detector based on 0.250 mm diameter plastic scintillating fibres. The fibres are wound to multilayer ribbons 2.4 m long and read out by 128 channel silicon photomultiplier arrays. The Scintillating Fibre (SciFi) tracker will cover a total active area of 360 m{sup 2}, arranged in 12 layers. The performances of prototype modules having 6 and 8 layers of fibre have been tested at the SPS at CERN. This talk focuses on basic properties of the prototype modules such as spatial resolution, single hit efficiency and light yield measured during the test beam campaigns in 2015.

  15. Sublimator Driven Coldplate Engineering Development Unit Test Results

    Science.gov (United States)

    Sheth, Rubik B.; Stephan, Ryan A.; Leimkuehler, Thomas O.

    2010-01-01

    The Sublimator Driven Coldplate (SDC) is a unique piece of thermal control hardware that has several advantages over a traditional thermal control scheme. The principal advantage is the possible elimination of a pumped fluid loop, potentially increasing reliability and reducing complexity while saving both mass and power. Because the SDC requires a consumable feedwater, it can only be used for short mission durations. Additionally, the SDC is ideal for a vehicle with small transport distances and low heat rejection requirements. An SDC Engineering Development Unit was designed and fabricated. Performance tests were performed in a vacuum chamber to quantify and assess the performance of the SDC. The test data was then used to develop correlated thermal math models. Nonetheless, an Integrated Sublimator Driven Coldplate (ISDC) concept is being developed. The ISDC couples a coolant loop with the previously described SDC hardware. This combination allows the SDC to be used as a traditional coldplate during long mission phases and provides for dissimilar system redundancy

  16. The Aluminum Ship Evaluation Model (ASEM) Static Test Results

    Science.gov (United States)

    1983-12-01

    At each load frame, one starboard hydraulic acuator or jack and one or two keel jacks (coupled with closed-loop, feedback system load cells) were used...zero, system lock and unlock, and lateral offset. Each test was performed enough times to establish repeatable linear strain response with load. A...to obtain the strain readings. The linearity in load versus strain response and, thus, the basic stress sensitivities (numbers of pounds per square

  17. 1-g model loading tests: methods and results

    Czech Academy of Sciences Publication Activity Database

    Feda, Jaroslav

    1999-01-01

    Roč. 2, č. 4 (1999), s. 371-381 ISSN 1436-6517. [Int.Conf. on Soil - Structure Interaction in Urban Civ. Engineering. Darmstadt, 08.10.1999-09.10.1999] R&D Projects: GA MŠk OC C7.10 Keywords : shallow foundation * model tests * sandy subsoil * bearing capacity * subsoil failure * volume deformation Subject RIV: JM - Building Engineering

  18. Test result of on-line coal ash content meter

    Energy Technology Data Exchange (ETDEWEB)

    Onodera, Jiro

    1988-10-25

    A two-line permeation type coal ash content meter was tested in on-line measurement. The used coal ash content meter irradiates gamma rays from A/sub m/ and C/sub s/, radioactive isotopes, to coal layer on the belt conveyer, continuously detects each of those gamma rays in permeation intensity by the scintillation counter, and digitally indicates the ash content indication value through the signal processing. At the coal quarrying stage by the low ash content coal preparation belt conveyer, test sample was collected at all times, and the relation of its ash content with the gamma ray intensity was investigated. In ash content range of 15 to 35%, an assumed error of 1.3% was obtained. The standardized intensity of gamma rays, as varying due to the thickness of belt, ambient temperature of detector and other factors, must be periodically tested in accuracy. Against sample, large in variance in water and vapor content, the adjustment by the water content meter is required. Further in case of the variance in H atom in coal, and Ca and Fe atoms in ash, as the mass damping coefficient varies against the Am gamma rays, it is advisable to apply, to each individual brend, the ash content calculation purpose regression formula. 8 references, 5 figures, 1 table.

  19. Low-speed wind tunnel test results of the Canard Rotor/Wing concept

    Science.gov (United States)

    Bass, Steven M.; Thompson, Thomas L.; Rutherford, John W.; Swanson, Stephen

    1993-01-01

    The Canard Rotor/Wing (CRW), a high-speed rotorcraft concept, was tested at the National Aeronautics and Space Administration (NASA) Ames Research Center's 40- by 80-Foot Wind Tunnel in Mountain View, California. The 1/5-scale model was tested to identify certain low-speed, fixed-wing, aerodynamic characteristics of the configuration and investigate the effectiveness of two empennages, an H-Tail and a T-Tail. The paper addresses the principal test objectives and the results achieved in the wind tunnel test. These are summarized as: i) drag build-up and differences between the H-Tail and T-Tail configuration, ii) longitudinal stability of the H-Tail and T-Tail configurations in the conversion and cruise modes, iii) control derivatives for the canard and elevator in the conversion and cruise modes, iv) aerodynamic characteristics of varying the rotor/wing azimuth position, and v) canard and tail lift/trim capability for conversion conditions.

  20. Multi-Mission Earth Vehicle Subsonic Dynamic Stability Testing and Analyses

    Science.gov (United States)

    Glaab, Louis J.; Fremaux, C. Michael

    2013-01-01

    Multi-Mission Earth Entry Vehicles (MMEEVs) are blunt-body vehicles designed with the purpose of transporting payloads from outer space to the surface of the Earth. To achieve high-reliability and minimum weight, MMEEVs avoid use of limited-reliability systems, such as parachutes, retro-rockets, and reaction control systems and rely on the natural aerodynamic stability of the vehicle throughout the Entry, Descent, and Landing (EDL) phase of flight. The Multi-Mission Systems Analysis for Planetary Entry (M-SAPE) parametric design tool is used to facilitate the design of MMEEVs for an array of missions and develop and visualize the trade space. Testing in NASA Langley?s Vertical Spin Tunnel (VST) was conducted to significantly improve M-SAPE?s subsonic aerodynamic models. Vehicle size and shape can be driven by entry flight path angle and speed, thermal protection system performance, terminal velocity limitations, payload mass and density, among other design parameters. The objectives of the VST testing were to define usable subsonic center of gravity limits, and aerodynamic parameters for 6-degree-of-freedom (6-DOF) simulations, for a range of MMEEV designs. The range of MMEEVs tested was from 1.8m down to 1.2m diameter. A backshell extender provided the ability to test a design with a much larger payload for the 1.2m MMEEV.

  1. Small-Scale Water Ingression and Crust Strength Tests (SSWICS) SSWICS-6 test data report: thermal hydraulic results, Rev. 0

    International Nuclear Information System (INIS)

    Lomperski, S.; Farmer, M.T.; Kilsdonk, D.; Aeschlimann, B.

    2011-01-01

    The Melt Attack and Coolability Experiments (MACE) program at Argonne National Laboratory addressed the issue of the ability of water to cool and thermally stabilize a molten core/concrete interaction (MCCI) when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. However, due to the integral nature of these tests, several questions regarding the crust freezing behavior could not be adequately resolved. These questions include: (1) To what extent does water ingression into the crust increase the melt quench rate above the conduction-limited rate and how is this affected by melt composition and system pressure? (2) What is the fracture strength of the corium crust when subjected to a thermal-mechanical load and how does it depend upon the melt composition? A series of separate-effects experiments are being conducted to address these issues. The first employs an apparatus designed to measure the quench rate of a pool of corium (∼ φ 30 cm; up to 20 cm deep). The main parameter to be varied in these quench tests is the melt composition since it is thought to have a critical influence on the crust cracking behavior which, in turn, alters quench rate. The issue of crust strength is being addressed with a second apparatus designed to mechanically load the crust produced by the quench tests. This apparatus measures the fracture strength of the crust while it is either at room temperature or above, the latter state being achieved with a heating element placed below the crust. The two apparatuses used to measure the melt quench rate and crust strength are jointly referred to as SSWICS (Small-Scale Water Ingression and Crust Strength). This report describes results of the sixth water ingression test, designated SSWICS-6. This test investigated

  2. Laboratory and test beam results from a large-area silicon drift detector

    CERN Document Server

    Bonvicini, V; Giubellino, P; Gregorio, A; Idzik, M; Kolojvari, A A; Montaño-Zetina, L M; Nouais, D; Petta, C; Rashevsky, A; Randazzo, N; Reito, S; Tosello, F; Vacchi, A; Vinogradov, L I; Zampa, N

    2000-01-01

    A very large-area (6.75*8 cm/sup 2/) silicon drift detector with integrated high-voltage divider has been designed, produced and fully characterised in the laboratory by means of ad hoc designed MOS injection electrodes. The detector is of the "butterfly" type, the sensitive area being subdivided into two regions with a maximum drift length of 3.3 cm. The device was also tested in a pion beam (at the CERN PS) tagged by means of a microstrip detector telescope. Bipolar VLSI front-end cells featuring a noise of 250 e/sup -/ RMS at 0 pF with a slope of 40 e/sup -//pF have been used to read out the signals. The detector showed an excellent stability and featured the expected characteristics. Some preliminary results will be presented. (12 refs).

  3. Stability Test of Partially Purified Bromelain from Pineapple (Ananas comosus (L.) Merr) Core Extract in Artificial Stomach Fluid

    Science.gov (United States)

    Setiasih, S.; Adimas, A. Ch. D.; Dzikria, V.; Hudiyono, S.

    2018-01-01

    This study aimed to isolate and purify bromelain from pineapple core (Ananascomosus (L.) Merr) accompanied by a stability test of its enzyme activity in artificial gastric juice. Purification steps start with fractionation by a precipitation method were carried out stepwise using several concentration of ammonium sulfate salt, followed by dialysis prosess and ion exchange chromatography on DEAE-cellulose column. Each step of purification produced an increasing specific activity in enzyme fraction, starting with crude extract, respectively: 0.276 U/mg; 14.591 U/mg; and 16.05 U/mg. Bromelain fraction with the highest level of purity was obtained in 50-80% ammonium sulphate fraction after dialyzed in the amount of 58.15 times compared to the crude extract. Further purification of the enzyme by DEAE-cellulose column produced bromelain which had a purity level 160-fold compared to crude enzyme. The result of bromelain stability test in artificial stomach juice by milk clotting units assay bromelain fraction have proteolytic activity in clotting milk substrate. Exposing bromelain fraction in artificial stomach juice which gave the highest core bromelain proteolytic activity was achieved at estimated volume of 0.4-0.5 mL. Exposure in a period of reaction time to artificial stomach juice that contained pepsin showed relatively stable proteolytic activity in the first 4 hours.

  4. Resolve. Version 2.5: Flammable Gas Accident Analysis Tool Acceptance Test Plan and Test Results

    International Nuclear Information System (INIS)

    LAVENDER, J.C.

    2000-01-01

    RESOLVE. Version 2 .5 is designed to quantify the risk and uncertainty of combustion accidents in double-shell tanks (DSTs) and single-shell tanks (SSTs). The purpose of the acceptance testing is to ensure that all of the options and features of the computer code run; to verify that the calculated results are consistent with each other; and to evaluate the effects of the changes to the parameter values on the frequency and consequence trends associated with flammable gas deflagrations or detonations

  5. Hanford 100-D Area Biostimulation Treatability Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Truex, Michael J.; Vermeul, Vincent R.; Fritz, Brad G.; Mackley, Rob D.; Mendoza, Donaldo P.; Elmore, Rebecca P.; Mitroshkov, Alexandre V.; Sklarew, Deborah S.; Johnson, Christian D.; Oostrom, Martinus; Newcomer, Darrell R.; Brockman, Fred J.; Bilskis, Christina L.; Hubbard, Susan S.; Peterson, John E.; Williams, Kenneth H.; Gasperikova, E.; Ajo-Franklin, J.

    2009-09-30

    Pacific Northwest National Laboratory conducted a treatability test designed to demonstrate that in situ biostimulation can be applied to help meet cleanup goals in the Hanford Site 100-D Area. In situ biostimulation has been extensively researched and applied for aquifer remediation over the last 20 years for various contaminants. In situ biostimulation, in the context of this project, is the process of amending an aquifer with a substrate that induces growth and/or activity of indigenous bacteria for the purpose of inducing a desired reaction. For application at the 100-D Area, the purpose of biostimulation is to induce reduction of chromate, nitrate, and oxygen to remove these compounds from the groundwater. The in situ biostimulation technology is intended to provide supplemental treatment upgradient of the In Situ Redox Manipulation (ISRM) barrier previously installed in the Hanford 100-D Area and thereby increase the longevity of the ISRM barrier. Substrates for the treatability test were selected to provide information about two general approaches for establishing and maintaining an in situ permeable reactive barrier based on biological reactions, i.e., a biobarrier. These approaches included 1) use of a soluble (miscible) substrate that is relatively easy to distribute over a large areal extent, is inexpensive, and is expected to have moderate longevity; and 2) use of an immiscible substrate that can be distributed over a reasonable areal extent at a moderate cost and is expected to have increased longevity.

  6. Aging test results of an asphalt membrane liner

    International Nuclear Information System (INIS)

    Buelt, J.L.; Barnes, S.M.

    1983-07-01

    The objective of the asphalt aging study described in this report was to determine the expected performance lifetime of a catalytically airblown asphalt membrane as a seepage barrier for inactive uranium mill tailings. The study, conducted by Pacific Northwest Laboratory for the Department of Energy's Uranium Mill Tailings Remedial Action Program, showed through chemical compatibility tests that the asphalt membrane is well suited for this purpose. The chemical compatibility tests were designed to accelerate the aging reactions in the asphalt and to determine the accelerated aging effect. Higher temperatures and oxygen concentrations proved to be effective acceleration parameters. By infrared spectral analysis, the asphalt was determined to have undergone 7 years of equivalent aging in a 3-month period when exposed to 40 0 C and 1.7 atm oxygen pressure. However, the extent of aging was limited to a maximum penetration of 0.5% of the total liner thickness. It was concluded that the liner could be expected to be effective as a seepage barrier for at least 1000 years before the entire thickness of the liner would be degraded

  7. Short-Term Test Results: Multifamily Home Energy Efficiency Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Lyons, J.

    2013-01-01

    Multifamily deep energy retrofits (DERs) represent great potential for energy savings, while also providing valuable insights on research-generated efficiency measures, cost-effectiveness metrics, and risk factor strategies for the multifamily housing industry. The Bay Ridge project is comprised of a base scope retrofit with a goal of achieving 30% savings (relative to pre-retrofit), and a DER scope with a goal of 50% savings (relative to pre-retrofit). The base scope has been applied to the entire complex, except for one 12-unit building which underwent the DER scope. Findings from the implementation, commissioning, and short-term testing at Bay Ridge include air infiltration reductions of greater than 60% in the DER building; a hybrid heat pump system with a Savings to Investment Ratio (SIR) > 1 (relative to a high efficiency furnace) which also provides the resident with added incentive for energy savings; and duct leakage reductions of > 60% using an aerosolized duct sealing approach. Despite being a moderate rehab instead of a gut rehab, the Bay Ridge DER is currently projected to achieve energy savings ≥ 50% compared to pre-retrofit, and the short-term testing supports this estimate.

  8. Test results of lithium pool-air reaction suppression systems

    International Nuclear Information System (INIS)

    Jeppson, D.W.

    1987-02-01

    Engineered reaction suppression systems were demonstrated to be effective in suppressing lithium pool-air reactions for lithium quantities up to 100 kg. Lithium pool-air reaction suppression system tests were conducted to evaluate suppression system effectiveness for potential use in fusion facilities in mitigating consequences of postulated lithium spills. Small-scale perforated and sacrificial cover plate suppression systems with delayed inert gas purging proved effective in controlling the lithium-air interaction for lithium quantities near 15 kg at initial temperatures up to 450 0 C. A large-scale suppression system with a sacrificial cover, a diverter plate, an inert gas atmosphere, and remotely retrievable catch pans proved effective in controlling lithium pool-air interaction for a 100-kg lithium discharge at an initial temperature of 550 0 C. This suppression system limited the maximum pool temperature to about 600 0 C less than that expected for a similar lithium pool-air reaction without a suppression system. Lithium aerosol release from this large-scale suppression system was a factor of about 10,000 less than that expected for a lithium pool-air reaction with no suppression system. Remote retrieval techniques for lithium cleanup, such as (1) in-place lithium siphoning and overhead crane dismantling, and (2) lithium catch pan removal by use of an overhead crane, were demonstrated as part of this large-scale test

  9. System test results from the GNC experiments on the PRISMA in-orbit test bed

    Science.gov (United States)

    Bodin, Per; Noteborn, Ron; Larsson, Robin; Chasset, Camille

    2011-04-01

    The PRISMA in-orbit test bed will demonstrate guidance, navigation, and control strategies for spacecraft formation flying and rendezvous. The project is funded by the Swedish National Space Board and the prime contractor is the Swedish Space Corporation. The project is further supported by the German Aerospace Center, the Technical University of Denmark, and the French Space Agency. PRISMA was launched on June 15, 2010 and after three weeks of operations, all on-board systems and units have passed an initial commissioning phase. Separation of the two PRISMA satellites from each other is expected by mid-August 2010. PRISMA consists of two spacecraft: MAIN and TARGET. The MAIN spacecraft has full orbit control capability while TARGET is attitude controlled only. The Swedish Space Corporation is responsible for three groups of guidance, navigation, and control experiments. These experiments include GPS- and vision-based formation flying during which the spacecraft will fly in passive as well as forced motion. The three experiments are: autonomous formation flying, proximity operations with final approach/recede maneuvers, and autonomous rendezvous. This paper presents system test results from two of these experiments as obtained with the flight-ready system. The system tests consist of a series of simulations performed on the flight model spacecraft with a large amount of hardware in the loop.

  10. Buoyancy-driven instability in a vertical cylinder: Binary fluids with Soret effect. I - General theory and stationary stability results

    Science.gov (United States)

    Hardin, G. R.; Sani, R. L.; Henry, D.; Roux, B.

    1990-01-01

    The buoyancy-driven instability of a monocomponent or binary fluid completely contained in a vertical circular cylinder is investigated, including the influence of the Soret effect for the binary mixture. The Boussinesq approximation is used, and the resulting linear stability problem is solved using a Galerkin technique. The analysis considers fluid mixtures ranging from gases to liquid metals. The flow structure is found to depend strongly on both the cylinder aspect ratio and the magnitude of the Soret effect. The predicted stability limits are shown to agree closely with experimental observations.

  11. BWR stability analysis: methodology of the stability analysis and results of PSI for the NEA/NCR benchmark task; SWR Stabilitaetsanalyse: Methodik der Stabilitaetsanalyse und PSI-Ergebnisse zur NEA/NCR Benchmarkaufgabe

    Energy Technology Data Exchange (ETDEWEB)

    Hennig, D.; Nechvatal, L. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1996-09-01

    The report describes the PSI stability analysis methodology and the validation of this methodology based on the international OECD/NEA BWR stability benchmark task. In the frame of this work, the stability properties of some operation points of the NPP Ringhals 1 have been analysed and compared with the experimental results. (author) figs., tabs., 45 refs.

  12. Results of Laboratory Testing of Advanced Power Strips: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Earle, L.; Sparn, B.

    2012-08-01

    This paper describes the results of a laboratory investigation to evaluate the technical performance of advanced power strip (APS) devices when subjected to a range of home entertainment center and home office usage scenarios.

  13. Research results on productivity stabilization by ultrasonic camera (plant with membrane ceramic elements during vine processing

    Directory of Open Access Journals (Sweden)

    V. T. Antufyev

    2016-01-01

    Full Text Available The article describes solutions to the problems of declining productivity of ceramic membrane elements for wine processing on the final manufacturing phase. A relative stabilization of filtration velocity, venting efficiency and wine lightening were experimentally confirmed during contacts with oscillation waves of ultrasonic transmitter on the ceramic filter. Which significantly reduced the cost of various preservatives to increase periods storage. To study the processes of wine processing by the proposed method it was made an experimental installation on the basis of pilot machine MRp-1/2 for bottling of quiet liquids and an ultrasonic device "Volna– M" UZTA-1/22-OM with a firmly, waveguide which transmits sound, fixed filter frame on the ultrasound emitter. To stabilize the performance of ultrasonic units with ceramic membrane elements without quality deterioration of wines it was empirically determined rational parameters of power of ultrasound input and pressure in the system. The given derived dependencies and graphs allow to define the time of relatively stable operating filter regime. It was revealed a significant cost reduction on filtration, as it allows escape from the contamination of the product by various preservatives, and increasing of storage duration in a sealed container during aseptic filling without a thermal sterilization. Ultrasonic emitter contact by superposition wave vibrations on the ceramic filter increases not only the efficiency of gas removal, but also improves the organoleptic characteristics, stabilizes the filters, improves their productivity. Gas removal creates unfavorable conditions for development of the yeast, which in turn increases the shelf life of semisweet wine.

  14. Stability of the offset V-osteotomy. Test jig development and saw bone model assessment.

    Science.gov (United States)

    Gonda, Elizabeth; Bauer, Gary R; Hillstrom, Howard J; Song, Jinsup; Cho, Helen H; Lundberg, Lori A

    2002-02-01

    In the offset V-bunionectomy used for hallux valgus repair, both the Kalish and the Vogler variations have a long dorsal arm, but the apex is more distal in the Kalish procedure. This study investigated the effect that pin orientation and location of the osteotomy apex have on weightbearing stability. The authors studied saw bone models that were loaded to failure in an Instron 4201 materials testing machine and, in addition, designed, fabricated, and used a unique jig assembly to help minimize data variability. Statistically significant differences were found between the surgical techniques and pin orientations: the Kalish osteotomy was stronger than the Vogler procedure, and in both osteotomies, the plantarly directed Kirschner wire orientation was stronger than the dorsally directed orientation.

  15. Testing baseline stability of some neutron monitors in Europe, Africa, and Asia

    Science.gov (United States)

    Ahluwalia, H. S.; Ygbuhay, R. C.

    2013-06-01

    For six decades, the global network of neutron monitors (NMs) has provided a continuous stream of very valuable data to the heliophysics community, leading to many insights into the myriad modes of charged particle transport in the tangled magnetic fields that permeate the 3D heliosphere. Earlier, Ahluwalia and Ygbuhay (2012) reported on the drifts in some high latitude NM counting rates in the American zone. We continue our enquiry by testing the stability of the counting rate baselines of some NMs operating in Europe, Africa, and Asia. The data from these detectors have been extremely valuable for the short-term time variation studies, but caution is advised in using the data for long-term studies from NMs with baselines that are drifting for cause(s) unknown.

  16. Use of Small-Angle Neutron Scattering in Testing the Stability of Ferrofluids

    CERN Document Server

    Balasoiu, M; Avdeev, M V; Aksenov, V L; Khokhryakov, A A; Bica, L D; Hasegan, D; Török, G; Rosta, L

    2004-01-01

    Stability of ferrofluids - colloidal solutions of magnetic particles covered with surfactants - is the main characteristic that determines the possibility to exploit ferrofluids in different industrial and biomedical applications. Small-angle neutron scattering (SANS) can be effectively used to reveal the aggregation and its change with time in ferrofluids under the action of magnetic field. Despite the fact that in most cases the detailed description of scattering is complicated, one can judge whether a ferrofluid is stable or not by simple analysis of changes in the mean scattering intensity. The advantages of SANS are that industrial samples can be tested without any additional modifications, as well as the real-time experiments with any magnetic load can be easily performed. Examples for a number of ferrofluids are given.

  17. A Stability Result for Stochastic Differential Equations Driven by Fractional Brownian Motions

    Directory of Open Access Journals (Sweden)

    Bruno Saussereau

    2012-01-01

    Full Text Available We study the stability of the solutions of stochastic differential equations driven by fractional Brownian motions with Hurst parameter greater than half. We prove that when the initial conditions, the drift, and the diffusion coefficients as well as the fractional Brownian motions converge in a suitable sense, then the sequence of the solutions of the corresponding equations converge in Hölder norm to the solution of a stochastic differential equation. The limit equation is driven by the limit fractional Brownian motion and its coefficients are the limits of the sequence of the coefficients.

  18. Filtration Understanding: FY10 Testing Results and Filtration Model Update

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, Richard C.; Billing, Justin M.; Burns, Carolyn A.; Peterson, Reid A.; Russell, Renee L.; Schonewill, Philip P.; Shimskey, Rick W.

    2011-04-04

    This document completes the requirements of Milestone 2-4, Final Report of FY10 Testing, discussed in the scope of work outlined in the EM31 task plan WP-2.3.6-2010-1. The focus of task WP 2.3.6 is to improve the U.S. Department of Energy’s (DOE’s) understanding of filtration operations for high-level waste (HLW) to improve filtration and cleaning efficiencies, thereby increasing process throughput and reducing the Na demand (through acid neutralization). Developing the cleaning/backpulsing requirements will produce much more efficient operations for both the Hanford Tank Waste Treatment and Immobilization Plant (WTP) and the Savannah River Site (SRS), thereby significantly increasing throughput by limiting cleaning cycles. The scope of this work is to develop the understanding of filter fouling to allow developing this cleaning/backpulsing strategy.

  19. Test Beam Results with a Full Size sTGC

    CERN Document Server

    Rettie, Sebastien; The ATLAS collaboration

    2014-01-01

    The forthcoming LHC upgrade to high luminosity will increase the background rate in the forward region of the ATLAS Muon Spectrometer (composed of three Big Wheels (BW) and a Small Wheel (SW) on each side of the detector) by approximately a factor of five. With such a rate some of the present Muon Spectrometer detectors in the SW region will produce fake triggers and will therefore be replaced by a New Small Wheel (NSW) composed of small Thin Gap Chamber (sTGC) and Micromegas planes. The aim of the detectors is to reach 100 micrometers position resolution and an online muon track reconstruction with better than 1 mrad precision. A full size sTGC quadruplet has been constructed and equipped with the first prototype of the dedicated front end electronics (VMM1). The performance of the sTGC quadruplet at the Fermilab test beam facility is presented here.

  20. Design and test results of the AMS RICH detector

    CERN Document Server

    Casadei, D.

    2002-01-01

    The AMS-02 detector will operate for at least 3 years on the International Space Station, measuring cosmic ray spectra at about 400 km above sea level over a wide range of geomagnetic latitude. The proximity focusing ring imaging \\v{C}erenkov counter of AMS-02 will measure the particle velocity $\\beta$ with $\\approx 0.1%$ uncertainty, making possible to discriminate Beryllium isotopes up to about 15 GeV/nucl. In addition its charge measurement will allow to study the elemental composition of cosmic rays up to Iron. A prototype of the RICH detector was tested with cosmic rays and on a ion beam accelerated by SPS, at CERN (October 2002).

  1. Short-Term Test Results. Multifamily Home Energy Efficiency Retrofit

    Energy Technology Data Exchange (ETDEWEB)

    Lyons, James [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States)

    2013-01-01

    Multifamily deep energy retrofits (DERs) represent great potential for energy savings, while also providing valuable insights on research-generated efficiency measures, cost-effectiveness metrics, and risk factor strategies for the multifamily housing industry. This report describes the Bay Ridge project, a base scope retrofit with a goal of achieving 30% savings (relative to pre-retrofit), and a DER scope with a goal of 50% savings (relative to pre-retrofit). Findings from the short-term testing at Bay Ridge include air infiltration reductions of greater than 60% in the DER building; a hybrid heat pump system with a Savings to Investment Ratio (SIR) > 1 (relative to a high efficiency furnace) which also provides the resident with added incentive for energy savings; and duct leakage reductions of > 60% using an aerosolized duct sealing approach.

  2. Test results, Industrial Solar Technology parabolic trough solar collector

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, V.E. [EG and G MSI, Albuquerque, NM (United States); Evans, L.R.; Matthews, C.W. [Sandia National Labs., Albuquerque, NM (United States)

    1995-11-01

    Sandia National Laboratories and Industrial Solar Technology are cost-sharing development of advanced parabolic trough technology. As part of this effort, several configurations of an IST solar collector were tested to determine the collector efficiency and thermal losses with black chrome and black nickel receiver selective coatings, combined with aluminized film and silver film reflectors, using standard Pyrex{reg_sign} and anti-reflective coated Pyrex{reg_sign} glass receiver envelopes. The development effort has been successful, producing an advanced collector with 77% optical efficiency, using silver-film reflectors, a black nickel receiver coating, and a solgel anti-reflective glass receiver envelope. For each receiver configuration, performance equations were empirically derived relating collector efficiency and thermal losses to the operating temperature. Finally, equations were derived showing collector performance as a function of input insolation value, incident angle, and operating temperature.

  3. Dφ vertex drift chamber construction and test results

    International Nuclear Information System (INIS)

    Clark, A.R.; Goozen, F.; Grudberg, P.; Klopfenstein, C.; Kerth, L.T.; Loken, S.C.; Oltman, E.; Strovink, M.; Trippe, T.G.

    1991-05-01

    A jet-cell based vertex chamber has been built for the D OE experiment at Fermilab and operated in a test beam there. Low drift velocity and diffusion properties were achieved using CO 2 (95%)-ethane(5%) at atmospheric pressure. The drift velocity is found to be consistent with [9.74+8.68(|E|-1.25)] μm/nsec where E is the electric field strength in (kV/cm < |E| z 1.6 kV/cm.) An intrinsic spatial resolution of 60 μm or better for drift distances greater than 2 mm is measured. The track pair efficiency is estimated to be better than 90% for separations greater than 630 μm. 8 refs., 6 figs., 1 tab

  4. EarthCube - Results of Test Governance in Geoscience Cyberinfrastructure

    Science.gov (United States)

    Davis, R.; Allison, M. L.; Keane, C. M.; Robinson, E.

    2016-12-01

    In September 2016, the EarthCube Test Enterprise Governance Project completed its three-year long process to engage the community and test a demonstration governing organization with the goal of facilitating a community-led process on designing and developing a geoscience cyberinfrastructure to transform geoscience research. The EarthCube initiative is making an important transition from creating a coherent community towards adoption and implemention of technologies that can serve scientists working in and across many domains. The emerging concept of a "system of systems" approach to cyberinfrastructure architecture is a critical concept in the EarthCube program, but has not been fully defined. Recommendations from an NSF-appointed Advisory Committee include: a. developing a succinct definition of EarthCube; b. changing the community-elected governance approach towards structured rather than consensus-driven decision-making; c. restructuring the process to articulate program solicitations; and d. producing an effective implementation roadmap. These are seen as prerequisites to adoption of best practices, system concepts, and evolving to a production track. The EarthCube governing body is preparing responses to the Advisory Committee findings and recommendations with a target delivery date of late 2016 but broader involvement may be warranted. We conclude that there is ample justification to continue evolving to a governance framework that facilitates convergence on a system architecture that guides EarthCube activities and plays an influential role in making operational the EarthCube vision of cyberinfrastructure for the geosciences. There is widespread community expectation for support of a multiyear EarthCube governing effort to put into practice the science, technical, and organizational plans that are continuing to emerge. However, the active participants in EarthCube represent a small sub-set of the larger population of geoscientists.

  5. Formulation, stability testing, and analytical characterization of melatonin-based preparation for clinical trial

    Directory of Open Access Journals (Sweden)

    Samira Filali

    2017-08-01

    Full Text Available A new institutional clinical trial assessed the improvement of sleep disorders in 40 children with autism treated by immediate-release melatonin formulation in different regimens (0.5 mg, 2 mg, and 6 mg daily for one month. The objectives of present study were to (i prepare low-dose melatonin hard capsules for pediatric use controlled by two complementary methods and (ii carry out a stability study in order to determine a use-by-date. Validation of preparation process was claimed as ascertained by mass uniformity of hard capsules. Multicomponent analysis by attenuated total reflectance Fourier transformed infrared (ATR-FTIR of melatonin/microcrystalline cellulose mixture allowed to identify and quantify relative content of active pharmaceutical ingredients and excipients. Absolute melatonin content analysis by high performance liquid chromatography in 0.5 mg and 6 mg melatonin capsules was 93.6%±4.1% and 98.7%±6.9% of theoretical value, respectively. Forced degradation study showed a good separation of melatonin and its degradation products. The capability of the method was 15, confirming a risk of false negative <0.01%. Stability test and dissolution test were compliant over 18 months of storage with European Pharmacopoeia. Preparation of melatonin hard capsules was completed manually and melatonin in hard capsules was stable for 18 months, in spite of low doses of active ingredient. ATR-FTIR offers a real alternative to HPLC for quality control of high-dose melatonin hard capsules before the release of clinical batches.

  6. Absence of fks1p in lager brewing yeast results in aberrant cell wall composition and improved beer flavor stability.

    Science.gov (United States)

    Wang, Jin-jing; Xu, Wei-na; Li, Xin'er; Li, Jia; Li, Qi

    2014-06-01

    The flavor stability during storage is very important to the freshness and shelf life of beer. However, beer fermented with a yeast strain which is prone to autolyze will significantly affect the flavor of product. In this study, the gene encoding β-1,3-glucan synthetase catalytic subunit (fks1) of the lager yeast was destroyed via self-clone strategy. β-1,3-glucan is the principle cell wall component, so fks1 disruption caused a decrease in β-1,3-glucan level and increase in chitin level in cell wall, resulting in the increased cell wall thickness. Comparing with wild-type strain, the mutant strain had 39.9 and 63.41 % less leakage of octanoic acid and decanoic acid which would significantly affect the flavor of beer during storage. Moreover, the results of European Brewery Convention tube fermentation test showed that the genetic manipulation to the industrial brewing yeast helped with the anti-staling ability, rather than affecting the fermentation ability. The thiobarbituric acid value reduced by 65.59 %, and the resistant staling value increased by 26.56 %. Moreover, the anti-staling index of the beer fermented with mutant strain increased by 2.64-fold than that from wild-type strain respectively. China has the most production and consumption of beer around the world, so the quality of beer has a significant impact on Chinese beer industry. The result of this study could help with the improvement of the quality of beer in China as well as around the world.

  7. Results of Edge Scatter Testing for a Starshade Mission

    Science.gov (United States)

    Smith, Daniel; Casement, L. Suzanne; Ellis, Scott; Stover, John; Warwick, Steve

    2017-01-01

    In the field of exoplanet detection and characterization, the use of a starshade, an external occulter in front of a telescope at large separations, has been identified as one of the highly promising methods to achieve the necessary high contrast imagery. Control of scattered sunlight from the edges of the starshade into the telescope has been identified as one of the key technology development areas in order to make the starshade feasible. Modeling of the scattered light has resulted in very different results so a campaign of experimentation with edge samples was undertaken to attempt to understand the discrepancies.Here, we present our results from the measurement of select samples of materials which would be suitable for manufacturing the starshade edge, and related models. We have focused on coating metallic samples for ease of fabrication: Titanium, Aluminum, and a Beryllium Copper alloy. Using standard machine shop methods, we fabricated samples which had sharp edges with radius of curvature (RoC) between 15 and 20 μm. We then had these samples coated by two suppliers to evaluate how well these coating types would conform to the edge and provide scatter suppression. The results of scatter measurements of these coated edge samples are presented. These scatter results have been incorporated into a new geometrical model in FRED which includes the details of the starshade mechanical model. This model predicts both the magnitude and distribution of the scattered sunlight in the image plane of a nominal telescope. We present these results, including a first effort at modeling the Solar System at 10 pc as seen by this mission architecture.

  8. Hot-Fire Test Results of an Oxygen/RP-2 Multi-Element Oxidizer-Rich Staged-Combustion Integrated Test Article

    Science.gov (United States)

    Hulka, J. R.; Protz, C. S.; Garcia, C. P.; Casiano, M. J.; Parton, J. A.

    2016-01-01

    As part of the Combustion Stability Tool Development project funded by the Air Force Space and Missile Systems Center, the NASA Marshall Space Flight Center was contracted to assemble and hot-fire test a multi-element integrated test article demonstrating combustion characteristics of an oxygen/hydrocarbon propellant oxidizer-rich staged-combustion engine thrust chamber. Such a test article simulates flow through the main injectors of oxygen/kerosene oxidizer-rich staged combustion engines such as the Russian RD-180 or NK-33 engines, or future U.S.-built engine systems such as the Aerojet-Rocketdyne AR-1 engine or the Hydrocarbon Boost program demonstration engine. For the thrust chamber assembly of the test article, several configurations of new main injectors, using relatively conventional gas-centered swirl coaxial injector elements, were designed and fabricated. The design and fabrication of these main injectors are described in a companion paper at this JANNAF meeting. New ablative combustion chambers were fabricated based on hardware previously used at NASA for testing at similar size and pressure. An existing oxygen/RP-1 oxidizer-rich subscale preburner injector from a previous NASA-funded program, along with existing and new inter-connecting hot gas duct hardware, were used to supply the oxidizer-rich combustion products to the oxidizer circuit of the main injector of the thrust chamber. Results from independent hot-fire tests of the preburner injector in a combustion chamber with a sonic throat are described in companion papers at this JANNAF conference. The resulting integrated test article - which includes the preburner, inter-connecting hot gas duct, main injector, and ablative combustion chamber - was assembled at Test Stand 116 at the East Test Area of the NASA Marshall Space Flight Center. The test article was well instrumented with static and dynamic pressure, temperature, and acceleration sensors to allow the collected data to be used for

  9. Translating laboratory compaction test results to field scale

    NARCIS (Netherlands)

    Roholl, J.A.; Thienen-Visser, K. van; Breunese, J.N.

    2016-01-01

    In recent studies on the surface subsidence caused by hydrocarbon recovery of the Groningen gas field, the predicted subsidence is overestimated if results of compaction experiments are not corrected by an empirical `upscaling factor'. In order to find an explanation for this `upscaling factor', an

  10. Results of testing improved traditional technique to reduce farmers ...

    African Journals Online (AJOL)

    The weather conditions and crop seasons seem not to be associated with monkeys' crop raiding behaviour in Uluguru Mountains. Therefore, the preliminary results suggest that the use of trained dogs in farms is cheap and can save up to 61.5 % of the current crop losses.al, 1998). The Mountains have outstanding various ...

  11. Up scaling and test results of an advanced Fresnel greenhouse

    NARCIS (Netherlands)

    B.A.J. van Tuijl; H.J.J. Janssen; H.F. de Zwart; Piet Sonneveld; Gert-Jan Swinkels

    2012-01-01

    A greenhouse with Fresnel lenses in the south facing roof and a receiver for concentrated Photovoltaics with water cooling (CPVT system) will result in electrical and thermal energy output from the solar energy excess entering a greenhouse. The PV system converts about half of the direct radiation

  12. VEGETABLE OILS AS SUBSTITUTION FOR DIESEL OIL Test results ...

    African Journals Online (AJOL)

    One result of the esterification process is that the viscosity is reduced to values which also occur with diesel oil. Similarly, the noteable differences between ..... Castor oil may be ot special int.erest 88 it is contrary to other vegetable oila eoluble in alcohol in all proportions and at room temperature. Hence alcohol could be ...

  13. Stability Tests of Positive Fractional Continuous-time Linear Systems with Delays

    Directory of Open Access Journals (Sweden)

    Tadeusz Kaczorek

    2013-06-01

    Full Text Available Necessary and sufficient conditions for the asymptotic stability of positive fractional continuous-time linear systems with many delays are established. It is shown that: 1 the asymptotic stability of the positive fractional system is independent of their delays, 2 the checking of the asymptotic stability of the positive fractional systems with delays can be reduced to checking of the asymptotic stability of positive standard linear systems without delays.

  14. ANNALS EXPRESS: Evaluation of sample stability for a quantitative faecal immunochemical test and comparison of two sample collection approaches.

    Science.gov (United States)

    Mellen, Samantha; de Ferrars, Maria; Chapman, Claire Louise; Bevan, Sarah; Turvill, James; Turnock, Daniel Charles

    2018-01-01

    Faecal immunochemical testing (FIT) is increasingly being used to triage symptomatic patients for suspected colorectal cancer. However, there are limited data on the effect of pre-analytical factors on faecal haemoglobin (f-Hb) when measured by FIT. The aim of this work was to evaluate the stability of f-Hb in faeces and to compare two methods of f-Hb sampling for FIT. Six patients provided faeces for f-Hb measurement which were transferred into specialised collection devices at baseline and at 1, 2, 3 and 7 days after storage at either room temperature or 4°C. A total of 137 patients returned both faeces transferred into the specialised collection device and faeces in a standard collection pot. A quantitative immunoturbidometric method was used to measure f-Hb and results were compared categorically. Discrepant results were assessed against diagnosis. f-Hb concentration declined rapidly within a day of storage at room temperature but results remained ⩾10 µg Hb/ g faeces in 5/6 patients after two days. An f-Hb result ⩾10 µg Hb/ g faeces was obtained in 4/6 patients after storage for seven days at 4⁰C. Results obtained when patients used specialised collection devices were significantly different to results obtained when faeces was transferred into the specialised collection device in the laboratory. There is considerable heterogeneity in f-Hb sample stability therefore samples should be transferred rapidly into specialised collection devices to prevent false negative results. Use of collection devices by patients can lead to false positive results compared to their use in a laboratory.

  15. Results of zinc injection test for Hamaoka Unit-1

    International Nuclear Information System (INIS)

    Kani, K.; Masuda, H.; Hayashi, Y.; Sudo, S.; Yamazaki, K.

    1998-01-01

    A zinc injection test was preformed at Hamaoka Nuclear Power Station Unit-1 for suppressing radiation dose rate on primary coolant recirculation piping after the replacement of piping. Zinc ion was injected by using injection system where Depleted Zinc Oxide was dissolved in carbonated water. Controllability of the system was sufficient to maintain concentration of zinc in primary water. The concentration of zinc in the primary coolant was controlled from 1 ppb to 5 ppb gradually. The increasing trend of concentration of Co-60 in the coolant was suppressed at zinc concentration of 3 ppb. It is evaluated that the deposition coefficient of Co-60 onto the surface of primary coolant recirculation piping was suppressed to one-third of previous cycle in average, and one-fourth of that just before injection start at zinc concentration of 5 ppb. We concluded that zinc injection is effective for suppressing dose rate on the primary coolant piping and no adverse effect occurs by zinc injection up to 5 ppb in the primary coolant. (J.P.N.)

  16. Results of field testing of waste forms using lysimeters

    International Nuclear Information System (INIS)

    McConnell, J.W. Jr.; Rogers, R.D.

    1988-01-01

    The purpose of the field testing task, using lysimeter arrays, is to expose samples of solidified resin waste to the actual physical, chemical, and microbiological conditions of disposal enviroment. Wastes used in the experiment include a mixture of synthetic organic ion exchange resins and a mixture of organic exchange resins and an inorganic zeolite. Solidification agents used to produce the 4.8-by 7.6-cm cylindrical waste forms used in the study were Portland Type I-II cement and Dow vinyl ester-styrene. Seven of these waste forms were stacked end-to-end and inserted into each lysimeter to provide a 1-L volume. There are 10 lysimeters, 5 at ORNL and 5 at ANL-E. Lysimeters used in this study were designed to be self-contained units which will be disposed at the termination of the 20-year study. Each is a 0.91-by 3.12-m right-circular cylinder divided into an upper compartment, which contains fill material, waste forms, and instrumentation, and an empty lower compartment, which collects leachate. Four lysimeters at each site are filled with soil, while a fifth (used as a control) is filled with inert silica oxide sand. Instrumentation within each lysimeter includes porous cup soil-water samplers and soil moisture/temperature probes. The probes are connected to an on-site data acquisition and storage system (DAS) which also collects data from a field meteorological station located at each site. 9 refs

  17. Veggie Hardware Validation Test Preliminary Results and Lessons Learned

    Science.gov (United States)

    Massa, Gioia D.; Dufour, Nicole F.; Smith, T. M.

    2014-01-01

    The Veggie hardware validation test, VEG-01, was conducted on the International Space Station during Expeditions 39 and 40 from May through June of 2014. The Veggie hardware and the VEG-01 experiment payload were launched to station aboard the SpaceX-3 resupply mission in April, 2014. Veggie was installed in an Expedite-the-Processing-of-Experiments-to-Space-Station (ExPRESS) rack in the Columbus module, and the VEG-01 validation test was initiated. Veggie installation was successful, and power was supplied to the unit. The hardware was programmed and the root mat reservoir and plant pillows were installed without issue. As expected, a small amount of growth media was observed in the sealed bags which enclosed the plant pillows when they were destowed. Astronaut Steve Swanson used the wet/dry vacuum to clean up the escaped particles. Water insertion or priming the first plant pillow was unsuccessful as an issue prevented water movement through the quick disconnect. All subsequent pillows were successfully primed, and the initial pillow was replaced with a backup pillow and successfully primed. Six pillows were primed, but only five pillows had plants which germinated. After about a week and a half it was observed that plants were not growing well and that pillow wicks were dry. This indicated that the reservoir was not supplying sufficient water to the pillows via wicking, and so the team reverted to an operational fix which added water directly to the plant pillows. Direct watering of the pillows led to a recovery in several of the stressed plants; a couple of which did not recover. An important lesson learned involved Veggie's bellows. The bellows tended to float and interfere with operations when opened, so Steve secured them to the baseplate during plant tending operations. Due to the perceived intensity of the LED lights, the crew found it challenging to both work under the lights and read crew procedures on their computer. Although the lights are not a safety

  18. DIRECT PHOTOGRAMMETRY USING UAV: TESTS AND FIRST RESULTS

    Directory of Open Access Journals (Sweden)

    F. Chiabrando

    2013-08-01

    Full Text Available In recent years, the quality of high resolution acquisition platforms for geomatic applications has decidedly increased, especially in the performance of the sensors devoted to image acquisition. The small size of these new sensors combined with the increase in resolution allows them to be easily mounted onto Unmanned Aerial Vehicles (UAVs; in particular, calibrated, very-high-resolution digital cameras for photogrammetric purposes such as digital terrain model (DTM and digital surface model (DSM extraction, orthophotos, and map realization have been used. In this case, the UAV performance allows a high quality product to be obtained, considering the pixel size and the accuracy of the DTM/DSM which could be obtained with automatic procedures. Several navigation sensors (GPS/GNSS and IMU-MEMS are embedded into UAVs in order to realize autonomous flight. The quality of these sensors, in terms of accuracy, depends on the model of UAV and its purpose. The navigation solution (position and attitude is estimated by the internal UAV sensor and can be employed to directly georeference the images, in order to produce an quick and easy description and analysis of the overlooked area. This is a good condition for semi-automatic procedures using a bundle-block photogrammetric approach. But is it possible to realize a direct photogrammetry? And what are the limits? Several tests were carried out over different areas and in different conditions using three different UAVs belonging to the Geomatics group of the Politecnico di Torino. In this paper, an investigation of the limits of some commercial UAVs is reported, defining a dedicated procedure to valuate their performance, especially considering the use of UAVs for direct photogrammetry.

  19. Results from tests of TFL Hydragard sampling loop

    International Nuclear Information System (INIS)

    Steimke, J.L.

    1995-03-01

    When the Defense Waste Processing Facility (DWPF) is operational, processed radioactive sludge will be transferred in batches to the Slurry Mix Evaporator (SME), where glass frit will be added and the contents concentrated by boiling. Batches of the slurry mixture are transferred from the SME to the Melter Feed Tank (MFT). Hydragard reg-sign sampling systems are used on the SME and the MFT for collecting slurry samples in vials for chemical analysis. An accurate replica of the Hydragard sampling system was built and tested in the thermal Fluids Laboratory (TFL) to determine the hydragard accuracy. It was determined that the original Hydragard valve frequently drew a non-representative sample stream through the sample vial that ranged from frit enriched to frit depleted. The Hydragard valve was modified by moving the plunger and its seat backwards so that the outer surface of the plunger was flush with the inside diameter of the transfer line when the valve was open. The slurry flowing through the vial accurately represented the composition of the slurry in the reservoir for two types of slurries, different dilution factors, a range of transfer flows and a range of vial flows. It was then found that the 15 ml of slurry left in the vial when the Hydragard valve was closed, which is what will be analyzed at DWPF, had a lower ratio of frit to sludge as characterized by the lithium to iron ratio than the slurry flowing through it. The reason for these differences is not understood at this time but it is recommended that additional experimentation be performed with the TFL Hydragard loop to determine the cause

  20. Advanced Rooftop Control (ARC) Retrofit: Field-Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Weimin; Katipamula, Srinivas; Ngo, Hung; Underhill, Ronald M.; Taasevigen, Danny J.; Lutes, Robert G.

    2013-07-31

    The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.