WorldWideScience

Sample records for spirometric measurements fvc

  1. Chronic Obstructive Pulmonary Disease as Measured By FEVl, FVC ...

    African Journals Online (AJOL)

    In both subjects and control groups, we assessed ventilatory function using a vitalograph spirometer to measure FEVl, FVC, andFEVl/FVC ratio. Results: Amongst the control group, various respiratory symptoms were prevalent in 0-2% of subjects, while impaired FEVl and FVC values suggestive of an obstructive ventilatory ...

  2. A novel scoring system to measure radiographic abnormalities and related spirometric values in cured pulmonary tuberculosis.

    Directory of Open Access Journals (Sweden)

    Renata Báez-Saldaña

    Full Text Available BACKGROUND: Despite chemotherapy, patients with cured pulmonary tuberculosis may result in lung functional impairment. OBJECTIVE: To evaluate a novel scoring system based on the degree of radiographic abnormalities and related spirometric values in patients with cured pulmonary tuberculosis. METHODS: One hundred and twenty seven patients with cured pulmonary tuberculosis were prospectively enrolled in a referral hospital specializing in respiratory diseases. Spirometry was performed and the extent of radiographic abnormalities was evaluated twice by each of two readers to generate a novel quantitative score. Scoring reproducibility was analyzed by the intra-class correlation coefficient (ICC and the Bland-Altman method. Multiple linear regression models were performed to assess the association of the extent of radiographic abnormalities with spirometric values. RESULTS: The intra-observer agreement for scoring of radiographic abnormalities (SRA showed an ICC of 0.81 (CI:95%, 0.67-0.95 and 0.78 (CI:95%, 0.65-0.92, for reader 1 and 2, respectively. Inter-observer reproducibility for the first measurement was 0.83 (CI:95%, 0.71-0.95, and for the second measurement was 0.74 (CI:95%, 0.58-0.90. The Bland-Altman analysis of the intra-observer agreement showed a mean bias of 0.87% and -0.55% and an inter-observer agreement of -0.35% and -1.78%, indicating a minor average systematic variability. After adjustment for age, gender, height, smoking status, pack-years of smoking, and degree of dyspnea, the scoring degree of radiographic abnormalities was significantly and negatively associated with absolute and percent predicted values of FVC: -0.07 (CI:95%, -0.01 to -0.04; -2.48 (CI:95%, -3.45 to -1.50; and FEV1 -0.07 (CI:95%, -0.10 to -0.05; -2.92 (CI:95%, -3.87 to -1.97 respectively, in the patients studied. CONCLUSION: The extent of radiographic abnormalities, as evaluated through our novel scoring system, was inversely associated with spirometric values

  3. A Novel Scoring System to Measure Radiographic Abnormalities and Related Spirometric Values in Cured Pulmonary Tuberculosis

    Science.gov (United States)

    Báez-Saldaña, Renata; López-Arteaga, Yesenia; Bizarrón-Muro, Alma; Ferreira-Guerrero, Elizabeth; Ferreyra-Reyes, Leticia; Delgado-Sánchez, Guadalupe; Cruz-Hervert, Luis Pablo; Mongua-Rodríguez, Norma; García-García, Lourdes

    2013-01-01

    Background Despite chemotherapy, patients with cured pulmonary tuberculosis may result in lung functional impairment. Objective To evaluate a novel scoring system based on the degree of radiographic abnormalities and related spirometric values in patients with cured pulmonary tuberculosis. Methods One hundred and twenty seven patients with cured pulmonary tuberculosis were prospectively enrolled in a referral hospital specializing in respiratory diseases. Spirometry was performed and the extent of radiographic abnormalities was evaluated twice by each of two readers to generate a novel quantitative score. Scoring reproducibility was analyzed by the intra-class correlation coefficient (ICC) and the Bland-Altman method. Multiple linear regression models were performed to assess the association of the extent of radiographic abnormalities with spirometric values. Results The intra-observer agreement for scoring of radiographic abnormalities (SRA) showed an ICC of 0.81 (CI:95%, 0.67–0.95) and 0.78 (CI:95%, 0.65–0.92), for reader 1 and 2, respectively. Inter-observer reproducibility for the first measurement was 0.83 (CI:95%, 0.71–0.95), and for the second measurement was 0.74 (CI:95%, 0.58–0.90). The Bland-Altman analysis of the intra-observer agreement showed a mean bias of 0.87% and -0.55% and an inter-observer agreement of -0.35% and -1.78%, indicating a minor average systematic variability. After adjustment for age, gender, height, smoking status, pack-years of smoking, and degree of dyspnea, the scoring degree of radiographic abnormalities was significantly and negatively associated with absolute and percent predicted values of FVC: -0.07 (CI:95%, -0.01 to -0.04); -2.48 (CI:95%, -3.45 to -1.50); and FEV1 -0.07 (CI:95%, -0.10 to -0.05); -2.92 (CI:95%, -3.87 to -1.97) respectively, in the patients studied. Conclusion The extent of radiographic abnormalities, as evaluated through our novel scoring system, was inversely associated with spirometric values, and

  4. A genome-wide association study identifies risk loci for spirometric measures among smokers of European and African ancestry.

    Science.gov (United States)

    Lutz, Sharon M; Cho, Michael H; Young, Kendra; Hersh, Craig P; Castaldi, Peter J; McDonald, Merry-Lynn; Regan, Elizabeth; Mattheisen, Manuel; DeMeo, Dawn L; Parker, Margaret; Foreman, Marilyn; Make, Barry J; Jensen, Robert L; Casaburi, Richard; Lomas, David A; Bhatt, Surya P; Bakke, Per; Gulsvik, Amund; Crapo, James D; Beaty, Terri H; Laird, Nan M; Lange, Christoph; Hokanson, John E; Silverman, Edwin K

    2015-12-03

    Pulmonary function decline is a major contributor to morbidity and mortality among smokers. Post bronchodilator FEV1 and FEV1/FVC ratio are considered the standard assessment of airflow obstruction. We performed a genome-wide association study (GWAS) in 9919 current and former smokers in the COPDGene study (6659 non-Hispanic Whites [NHW] and 3260 African Americans [AA]) to identify associations with spirometric measures (post-bronchodilator FEV1 and FEV1/FVC). We also conducted meta-analysis of FEV1 and FEV1/FVC GWAS in the COPDGene, ECLIPSE, and GenKOLS cohorts (total n = 13,532). Among NHW in the COPDGene cohort, both measures of pulmonary function were significantly associated with SNPs at the 15q25 locus [containing CHRNA3/5, AGPHD1, IREB2, CHRNB4] (lowest p-value = 2.17 × 10(-11)), and FEV1/FVC was associated with a genomic region on chromosome 4 [upstream of HHIP] (lowest p-value = 5.94 × 10(-10)); both regions have been previously associated with COPD. For the meta-analysis, in addition to confirming associations to the regions near CHRNA3/5 and HHIP, genome-wide significant associations were identified for FEV1 on chromosome 1 [TGFB2] (p-value = 8.99 × 10(-9)), 9 [DBH] (p-value = 9.69 × 10(-9)) and 19 [CYP2A6/7] (p-value = 3.49 × 10(-8)) and for FEV1/FVC on chromosome 1 [TGFB2] (p-value = 8.99 × 10(-9)), 4 [FAM13A] (p-value = 3.88 × 10(-12)), 11 [MMP3/12] (p-value = 3.29 × 10(-10)) and 14 [RIN3] (p-value = 5.64 × 10(-9)). In a large genome-wide association study of lung function in smokers, we found genome-wide significant associations at several previously described loci with lung function or COPD. We additionally identified a novel genome-wide significant locus with FEV1 on chromosome 9 [DBH] in a meta-analysis of three study populations.

  5. A 2-year follow-up of spirometric parameters in workers of a tile and ceramic industry, Yazd, southeastern Iran.

    Science.gov (United States)

    Mehrparvar, A H; Mirmohammadi, S J; Mostaghaci, M; Davari, M H; Hashemi, S H

    2013-04-01

    Respiratory diseases cause a considerable amount of morbidity and mortality in the world. Pulmonary function tests are important measures for the diagnosis and management of respiratory disorders. Workers in tile and ceramic industry are exposed to high amounts of respiratory pollutants. To identify the changes in spirometric parameters in a 2-year period among tile and ceramic workers in Yazd and compare it with a control group. The study was conducted in 5 tile and ceramic factories selected by cluster sampling between 2009 and 2011 in Yazd, southeastern Iran. Demographic data and spirometric parameters of participants were recorded. Spirometric parameters were significantly reduced during the 2 years. The largest decrease was observed in FVC (≈500 mL) in ball-mill and grinding after 2 years. Decrease in all spirometric parameters was significantly higher in industrial workers than office workers. Respiratory exposure in tile and ceramic industry can significantly affect pulmonary function tests.

  6. Correlation of six minute walk test with spirometric indices in chronic obstructive pulmonary disease patients: A tertiary care hospital experience

    Directory of Open Access Journals (Sweden)

    Abhijit Kundu

    2015-01-01

    Full Text Available Background: Six-minute walk test (6MWT is a simple, objective, reproducible test which correlated well with different spirometric indices, and thus able to predict severity of chronic obstructive pulmonary disease (COPD and can replace spirometry in resource poor set-up. Aims and Objectives: To find out correlation between spirometric indices (forced expiratory volume in 1 s (FEV 1 , forced vital capacity (FVC, and peak expiratory flow rate (PEFR and 6-minute walk distance (6MWD in COPD patients, and thus to assess whether 6MWT can replace spirometry. Settings and Design: Institution based cross-sectional observational study. Materials and Methods: Eighty patients of COPD (diagnosis confirmed by Global Initiative for Chronic Obstructive Lung Disease (GOLD 2010 criteria were enrolled for the study after applying exclusion criteria. All patients underwent spirometric measurement of FEV 1 , FVC, PEFR, and ratio of FEV 1 and FVC and test repeated after bronchodilation by 200-400 μg of salbutamol. 6MWT was performed following American Thoracic Society (ATS protocol of 6MWT and distance was measured in meters. Results: We found significant linear correlation of 6MWT with post-FEV 1 (r = 0.478, P < 0.001, post-FVC (r = 0.454, P < 0.001, and post-PEFR (r = 0.408, P < 0.001, but no correlation with FEV 1 /FVC (r = 0.250, P = 0.025. We also found significant correlation of 6MWT with BODE (body mass index (BMI, airway obstruction, dyspnea, and exercise capacity index (r = −0.419, P < 0.001. Conclusions: 6MWT can be a useful replacement of spirometry in assessment of severity of COPD.

  7. Examination of relationship between 30 second wingate test performance and spirometric respiratory functions in young adults

    Directory of Open Access Journals (Sweden)

    C Arslan

    2009-07-01

    Full Text Available Objective: This work has been planed to investigate whether the correlation between one of the important component of the sports performance spirometric respiratory function (SRF and 30 s Wingate Test (WT parameters of young adults who have different physical fitness level. Materials and Methods: This work included a total of 166 subjects those are 98 young boys (20.30±1.93 and 68 young girls (19.65±2.18. The subjects were divided into two groups namely regular exercises group (EG who make a regular exercises during 4.0±1.50 years and sedentary groups (SG. Both group’s subjects have similar age, height, weight and body mass index (BMI kg/m2. All the subjects were performed spirometric respiratory function test and WT power performance test. Statistical analyses were performed by SPSS computer program and the groups were compared to each other by using Independent Samples t test calculation and the correlation relation levels were calculated by using linear regression analysis. Results: In the view of physical peculiarities, it has not been found any difference between research groups that EG and SG (P>0.05. In the meaning of the measured spirometric respiratory functions and WT power performance, with the advantage of making regular sports, according to SG groups, the boys and girls EG groups showed differences (P<0.05. The correlational relationship between the spirometric and WT power parameters; it has been observed significant correlation between peak power (PP, mean power (MP, peak power/weight (PP/Wkg, mean power/weight (MP/Wkg form WT parameters and VC, FVC, FEV1, FEV1/FVC (% FEF25-75, PEF and MVV form respiration function (P<0.05 and P<0.001. On the other hand, it has not been found any significant correlation between WT anaerobic fatigue index (AFI % and respiratory functions (P<0.05. Conclusion: In this work, the tested spirometric respiratory functions have got an active role in the WT power parameters. It has been confirmed that

  8. Measures of bronchodilator response of FEV1, FVC and SVC in a Swedish general population sample aged 50–64 years, the SCAPIS Pilot Study

    Directory of Open Access Journals (Sweden)

    Torén K

    2017-03-01

    Full Text Available K Torén,1 B Bake,1 A-C Olin,1 G Engström,2 A Blomberg,3 J Vikgren,4 J Hedner,5 J Brandberg,4 HL Persson,6,7 CM Sköld,8 A Rosengren,9 G Bergström,9 C Janson10 1Section of Occupational and Environmental Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, 2Department of Clinical Science, Lund University, Malmö, 3Division of Medicine/Respiratory Medicine, Department of Public Health and Clinical Medicine, Umeå University, Umeå, 4Department of Radiology, Institute of Clinical Sciences, 5Department of Internal Medicine/Lung Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, 6Department of Respiratory Medicine, 7Department of Medicine and Health Sciences, Linköping University, Linköping, 8Respiratory Medicine Unit, Department of Medicine Solna, Centre for Molecular Medicine, Karolinska Institutet, Stockholm, 9Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, 10Department of Medical Sciences, Clinical Physiology and Lung, Allergy and Sleep Research, Uppsala University, Uppsala, Sweden Background: Data are lacking from general population studies on how to define changes in lung function after bronchodilation. This study aimed to analyze different measures of bronchodilator response of forced expiratory volume in 1 second (FEV1, forced vital capacity (FVC and slow vital capacity (SVC. Materials and methods: Data were derived from the Swedish Cardiopulmonary Bioimage Study (SCAPIS Pilot study. This analysis comprised 1,050 participants aged 50–64 years from the general population. Participants were investigated using a questionnaire, and FEV1, FVC and SVC were recorded before and 15 minutes after inhalation of 400 µg of salbutamol. A bronchodilator response was defined as the relative change from baseline value expressed as the difference in units of percent predicted normal

  9. The Evaluation of Relationship between Spirometric Disorders and Methyl methacrylate in Dental Laboratories Personnel

    Directory of Open Access Journals (Sweden)

    E. Nadi

    2010-04-01

    Full Text Available Introduction & Objective: Methyl methacrylate (MMA, as a monomer of acrylic resin that has a wide variety of usages in denture fabrication, is considered as an air pollution indicator in the laboratories. Occupational exposure to these compound vapors can cause respiratory hypersensitivity, occupational asthma, eye and skin irritation and Allergic Contact Dermatitis (ACD. Therefore control of MMA exposure may promote the personnel’s health. The aim of this study was to determine the relationship between spirometric disorders and methyl methacrylate in dental laboratories personnel.. Materials & Methods: In this case control study, exposure of time-weighted average (TWA and short-term exposure level (STEL were measured with MMA vapors in 39 randomly selected male employee (case group in 25 denture fabrication laboratories in Hamadan city. The air samples were collected by sorbent tubes containing chromosorb (XAD2( and analyzed by gas chromatograph equipped with FID detector based on NIOSH method. In addition 30 men whitout occupational exposure to air pollutants (control group were selected to compare the variation of spirometric parameters. Spirometric parameters of the case and control groups such as FVC, FEV1, FEV1/FVC and FEF25-75 were measured by Vitalograph spirometer (model: 2120 on ATS method, after the standard questionnaire of respiratory diseases had been completed during an interview and medical examination..Results: The mean of MMA concentration was 132.87 ± 220.67 ppm for STEL and 1.95 ± 3.59 ppm for TWA.The relationship between MMA concentration in the STEL and TWA exposures was significant (P<0.05 and the relationship between MMA concentration and ventilation was significant just for STEL. In this study no relationship between MMA concentration and spirometric parameters in both STEL and TWA exposures was found. Also there was no significant difference between spirometric parameters of the case group and normal values of the

  10. The Effects of Ramadan Intermittent Fasting (RIF) on Spirometric Data of Stable COPD Patients: A Pilot Study.

    Science.gov (United States)

    Zouari, Hajer; Latiri, Imed; Mahjoub, Mohamed; Boussarsar, Mohamed; Benzarti, Mohamed; Abdelghani, Ahmed; Ben Saad, Helmi

    2018-03-01

    No previous study has raised the effects of RIF on lung function data of chronic obstructive pulmonary disease (COPD) patients. The objective of the present study was to assess the effects of RIF on spirometric data measured in male patients with a stable COPD. Sixteen patients with stable COPD (mean ± SD of age: 64 ± 7 years) who fasted during Ramadan volunteered to the study. Three sessions (Before-R, End-R, and After-R) were selected for spirometry tests that were consistently performed 2.5-4.5 hr before fasting break. Assessment sessions comprised: forced vital capacity (FVC), 1st s forced expiratory volume (FEV 1 ), FEV 1 /FVC, peak expiratory flow (PEF), maximal mid-expiratory flow (MMEF), and forced expiratory flow rate at the x% of FVC to be exhaled (FEFx%). A reversibility test was performed only during the Before-Ramadan session. Spirometric data were expressed in percentages of local reference values. Findings were analyzed by applying repeated measures analysis of variance. The mean ± SD of the postbronchodilator FEV 1 /FVC ratio and the FEV 1 were, respectively, 0.52 ± 0.14 and 48 ± 19%. The mean ± SD of FEV 1 (Before-R: 47 ± 19, End-R: 45 ± 18, After-R: 44 ± 19%), FVC (Before-R: 73 ± 18, End-R: 71 ± 16, After-R: 69 ± 17%), FEV 1 /FVC (Before-R: 67 ± 16, End-R: 66 ± 16, After-R: 65 ± 16%), PEF (Before-R: 46 ± 19, End-R: 47 ± 22, After-R: 45 ± 21%), MMEF (Before-R: 19 ± 10, End-R: 18 ± 8, After-R: 18 ± 9%), FEF 25% (Before-R: 16 ± 6, End-R: 16 ± 5, After-R: 15 ± 5%), FEF 50% (Before-R: 21 ± 14, End-R: 20 ± 12, After-R: 20 ± 12%) and FEF 75% (Before-R: 27 ± 19, End-R: 27 ± 19, After-R: 27 ± 19%) were not significantly influenced by RIF. RIF did not bring about any significant changes in the spirometric data of stable COPD male patients fasting the 2016 holy month of Ramadan.

  11. Study of computerized spirometric parameters of traffic police personnel of Saurashtra region, Gujarat, India.

    Science.gov (United States)

    Makwana, Amit H; Solanki, Jayesh D; Gokhale, Pradnya A; Mehta, Hemant B; Shah, Chinmay J; Gadhavi, Bhakti P

    2015-01-01

    Air pollution due to road traffic is a serious health hazard and air quality crisis in cities is mainly due to vehicular emission. Thus the persons who are continuously exposed are at an increased risk. The study was carried out to evaluate the extent of impairment in lung function in traffic police personnel compared to matched unexposed control group. A cross-sectional study was conducted to measure the spirometric parameters of 100 traffic police personnel, aged 20-55 years, working in Saurashtra region, as compared to matched control group, consisting of 100 unexposed males. Measurement of lung volumes and capacities was done with SPIROEXCEL. The statistical analysis was carried out with Graph pad instat 3. Traffic police personnel had significantly declined forced vital capacity (FVC), forced expiratory volume in one second (FEV 1), slow vital capacity (SVC) and maximum voluntary ventilation (MVV) when compared with predictive normal values, which is probably due to exposure to vehicular exhaust. Comparison of test values between groups showed significantly reduced FVC, MVV and increased FEV1/FVC ratio and insignificantly declined FEV1 and SVC in cases as compared to controls. Traffic personnel with longer duration of exposure showed significantly reduced lung functions than those with shorter duration. Smokers showed lower test values as compared to non-smokers with significance only in unexposed group. The effect of pollution by vehicular exhausts may be responsible for these pulmonary function impairments and traffic police personnel should be offered personal protective or preventive measures.

  12. A Simple Measure to Assess Hyperinflation and Air Trapping: 1-Forced Expiratory Volume in Three Second / Forced Vital Capacity

    Directory of Open Access Journals (Sweden)

    Sermin Börekçi

    2017-04-01

    Full Text Available Background: Several recent studies have suggested that 1 minus-forced expiratory volume expired in 3 seconds / forced vital capacity (1-FEV3/FVC may be an indicator of distal airway obstruction and a promising measure to evaluate small airways dysfunction. Aims: To investigate the associations of 1-FEV3/FVC with the spirometric measures and lung volumes that assess small airways dysfunction and reflects hyperinflation and air trapping. Study Design: Retrospective cross-sectional study. Methods: Retrospective assessment of a total of 1110 cases who underwent body plethysmographic lung volume estimations between a time span from 2005 to 2012. Patients were assigned into two groups: firstly by FEV1/FVC (FEV1/FVC <70% vs. FEV1/FVC ≥70%; secondly by FEV3/FVC < lower limits of normal (LLN (FEV3/FVC < LLN vs. FEV3/FVC ≥ LLN. Spirometric indices and lung volumes measured by whole-body plethysmography were compared in groups. Also the correlation of spirometric indices with measured lung volumes were assessed in the whole-study population and in subgroups stratified according to FEV1/FVC and FEV3/FVC. Results: Six hundred seven (54.7% were male and 503 (45.3% were female, with a mean age of 52.5±15.6 years. Mean FEV3/FVC and 1-FEV3/FVC were 87.05%, 12.95%, respectively. The mean 1-FEV3/FVC was 4.9% in the FEV1/FVC ≥70% group (n=644 vs. 24.1% in the FEV1/FVC <70% group (n=466. A positive correlation was found between 1-FEV3/FVC and residual volume (r=0.70; p<0.0001, functional residual capacity-pleth (r=0.61; p<0.0001, and total lung capacity (r=0.47; p<0.0001. 1-FEV3/FVC was negatively correlated with forced expiratory flow25-75 (r=−0.84; p<0.0001. The upper limit of 95% confidence interval for 1-FEV3/FVC was 13.7%. 1-FEV3/FVC showed significant correlations with parameters of air trapping and hyperinflation measured by whole-body plethysmography. Importantly, these correlations were higher in study participants with FEV1/FVC <70% or FEV3/FVC

  13. Study of computerized spirometric parameters of traffic police personnel of Saurashtra region, Gujarat, India

    Directory of Open Access Journals (Sweden)

    Amit H Makwana

    2015-01-01

    Full Text Available Background and Objectives: Air pollution due to road traffic is a serious health hazard and air quality crisis in cities is mainly due to vehicular emission. Thus the persons who are continuously exposed are at an increased risk. The study was carried out to evaluate the extent of impairment in lung function in traffic police personnel compared to matched unexposed control group. Materials and Methods: A cross-sectional study was conducted to measure the spirometric parameters of 100 traffic police personnel, aged 20-55 years, working in Saurashtra region, as compared to matched control group, consisting of 100 unexposed males. Measurement of lung volumes and capacities was done with SPIROEXCEL. The statistical analysis was carried out with Graph pad instat 3. Results: Traffic police personnel had significantly declined forced vital capacity (FVC, forced expiratory volume in one second (FEV 1, slow vital capacity (SVC and maximum voluntary ventilation (MVV when compared with predictive normal values, which is probably due to exposure to vehicular exhaust. Comparison of test values between groups showed significantly reduced FVC, MVV and increased FEV1/FVC ratio and insignificantly declined FEV1 and SVC in cases as compared to controls. Traffic personnel with longer duration of exposure showed significantly reduced lung functions than those with shorter duration. Smokers showed lower test values as compared to non-smokers with significance only in unexposed group. Conclusion: The effect of pollution by vehicular exhausts may be responsible for these pulmonary function impairments and traffic police personnel should be offered personal protective or preventive measures.

  14. Determinants of spirometric abnormalities among silicotic patients in Hong Kong.

    Science.gov (United States)

    Leung, Chi C; Chang, Kwok C; Law, Wing S; Yew, Wing W; Tam, Cheuk M; Chan, Chi K; Wong, Man Y

    2005-09-01

    Silicosis is the second commonest notified occupational disease in Hong Kong. To characterize the determinants of spirometric abnormalities in silicosis. The spirometric patterns of consecutive silicotic patients on confirmation by the Pneumoconiosis Medical Board from 1991 to 2002 were correlated with demographic characteristics, occupational history, smoking history, tuberculosis (TB) history and radiographic features by univariate and multiple regression analyses. Of 1576 silicotic patients included, 55.6% showed normal spirometry, 28.5% normal forced vital capacity (FVC>or=80% predicted) but reduced forced expiratory ratio (FERjob type, history of TB, size of lung nodules and progressive massive fibrosis (PMF) were all significantly associated with airflow limitation on univariate analysis (all P<0.05), while sex and profusion of nodules were not. Only age, cigarette pack-years, history of TB, size of lung nodules and PMF remained as significant independent predictors of airflow obstruction in multiple logistic regression analysis. After controlling for airflow obstruction, only shorter exposure duration, history of TB and profusion of nodules were significant independent predictors of reduced FVC. As well as age, history of TB, cigarette pack-years, PMF and nodule size contributed comparable effects to airflow obstruction in multiple linear regression analyses, while profusion of nodules was the strongest factor for reduced vital capacity. In an occupational compensation setting, disease indices and history of tuberculosis are independent predictors of both airflow obstruction and reduced vital capacity for silicotic patients.

  15. Spirometric reference values for Hopi Native American children ages 4-13 years.

    Science.gov (United States)

    Arnall, David A; Nelson, Arnold G; Hearon, Christopher M; Interpreter, Christina; Kanuho, Verdell

    2016-04-01

    Spirometry is the most important tool in diagnosing pulmonary disease and is the most frequently performed pulmonary function test. Respiratory disease is also one of the greatest causes for morbidity and mortality on the Hopi Nation, but no specific reference equations exist for this unique population. The purpose of this study was to determine if population reference equations were necessary for these children and, if needed, to create new age and race-specific pulmonary nomograms for Hopi children. Two hundred and ninety-two healthy children, ages 4-13 years, attending Hopi Nation elementary schools in Arizona, were asked to perform spirometry for a full battery of pulmonary volumes and capacities of which the following were analyzed: forced vital capacity (FVC), forced expiratory volume in 1 sec (FEV1 ), FEV1 % (FEV1 /FVC), FEF25-75% and peak expiratory flow rate (PEFR). Spirometric data from Navajo children living in the same geographical region as the Hopi children were compared as well as spirometric data from common reference values used for other ethnic groups in the USA. Spirometry tests from 165 girls and 127 boys met American Thoracic Society quality control standards. We found that the natural log of height, body mass and age were significant predictors of FEV1 , FVC, and FEF25-75% in the gender-specific models and that lung function values all increased with height and age as expected. The predictions using the equations derived for Navajo, Caucasian, Mexican-American, African-American youth were significantly different (P ≤ 0.05) from the predictions derived from the Hopi equations for all of the variables across both genders, with the exceptions of Hopi versus Navajo FEV1 /FVC in the males and Hopi versus Caucasians FEF25-75% in the females. Thus it would appear for this population important to have specific formulae to provide more accurate reference values. © 2015 Wiley Periodicals, Inc.

  16. Genome-wide linkage analysis of bronchodilator responsiveness and post-bronchodilator spirometric phenotypes in chronic obstructive pulmonary disease

    NARCIS (Netherlands)

    Palmer, LJ; Celedon, JC; Chapman, HA; Speizer, FE; Weiss, ST; Silverman, EK

    2003-01-01

    Chronic obstructive pulmonary disease (COPD) is a common, complex disease associated with significant and increasing morbidity and mortality. The cardinal feature of COPD is persistent airflow obstruction, measured by reductions in quantitative spirometric indices including forced expiratory volume

  17. Change in FVC and survival in chronic fibrotic hypersensitivity pneumonitis.

    Science.gov (United States)

    Gimenez, Andrea; Storrer, Karin; Kuranishi, Lilian; Soares, Maria Raquel; Ferreira, Rimarcs Gomes; Pereira, Carlos A C

    2018-04-01

    The predictive value of the decline in FVC by ≥10% on survival in patients with fibrotic hypersensitivity pneumonitis is unknown. Of 112 patients included, 66 (59%) had surgical lung biopsies. Patients with ≥10% decline in predicted FVC after 6-12 months had a significantly increased risk of all-cause mortality (median survival 53 months, 95% CI 37 to 69 vs 139 months, 95% CI 66 to 212 months, p=0.007). On multivariate analysis remained associated with increasing mortality: decline in FVC by ≥10% (HR 4.13, 95% CI 1.96 to 8.70, p=0.005), lower FVC% (HR 1.03, 95% CI 1.01 to 1.05, p=0.003) and with decreasing mortality improvement with antigen avoidance (HR 0.18, 95% CI 0.04 to 0.77, p=0.021). © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  18. Sleep pattern in patients with Chronic Obstructive Pulmonary Disease and correlation among gasometric, spirometric, and polysomnographic variables

    Directory of Open Access Journals (Sweden)

    Santos Carlos Eduardo Ventura Gaio dos

    2003-01-01

    Full Text Available OBJECTIVE: There are few studies on chronic obstructive pulmonary disease (COPD establishing differences between the functional parameters of the disease and sleep variables. The aim of the study was to describe the sleep pattern of these patients and to correlate spirometric, gasometric and polysomnographic variables. METHODS: Transversal study using COPD patients submitted to spirometry, arterial gasometry, and polysomnography. RESULTS: 21 male patients were studied with average age = 67 ± 9; 7 ± 4 average points in the Epworth sleepiness scale, average Tiffenau's index (FEV1/FVC = 54 ± 13.0%, average PaO2 = 68 ± 11 mmHg, average PaCO2 = 37 ± 6 mmHg. Sleep efficiency decreased (65 ± 16% with the reduction of slow wave sleep (8 ± 9% and rapid eye movement (REM sleep (15 ± 8%. Average T90 was 43 ± 41%. Average apnea-hypopnea index (AHI = 3 ± 5/h, where two patients (9.5% presented obstructive sleep apnea. A significant correlation was observed between PaO2 and T90 (p < 0.01, PaCO2 and T90 (p < 0.05, and AHI and the cardiac rate during REM (p < 0.01. A higher number of arousals and stage change was observed. There was no linear correlation between spirometric and polysomnographic variables. CONCLUSION: Poor sleep quality of these patients was characterized by low sleep efficiency, high number of awakenings and shift of stages. There were no correlations between the spirometric and polysomnographic variables.

  19. Overweight effect on spirometric parameters in adolescents undergoing exercise.

    Science.gov (United States)

    Costa, Rayana de Oliveira; Silva, Juliana Pereira; Lacerda, Eliana Mattos; Dias, Rodrigo; Pezolato, Vitor Alexandre; Silva, Carlos Alberto da; Krinski, Kleverton; Correia, Marco Aurélio de Valois; Cieslak, Fabrício

    2016-01-01

    To evaluate effects of overweight on spirometric parameters in adolescents who underwent bronchial provocation test for exercise. We included 71 male adolescents. The diagnosis of asthma was done based on participants' clinical history and on the International Study Questionnaire Asthma and Allergies in Childhood, and the diagnosis of obesity was based on body mass index above 95th percentile. The bronchospasm induced by exercise was assessed using the run-walk test on a treadmill for eight minutes. The decrease in forced expiratory volume in one second > or equal to 10% before exercise was considered positive, and to calculate the intensity in exercise-induced bronchospasm we measured the maximum percentage of forced expiratory volume in one second and above the curve area. Data analysis was carried out using the Mann-Whitney U test and Friedman test (ANOVA), followed by Wilcoxon test (padolescentes submetidos ao teste de broncoprovocação por exercício. Participaram do estudo 71 adolescentes do sexo masculino. O diagnóstico de asma foi obtido por meio de histórico clínico e do questionário International Study of Asthma and Allergies in Childhood, e o de obesidade, pelo índice de massa corporal acima do percentil 95. Para avaliar o broncoespasmo induzido pelo exercício, utilizou-se o teste correr/caminhar em esteira ergométrica, com duração de 8 minutos, considerando positivo se diminuição do volume expiratório forçado no primeiro segundo >10% do valor pré-exercício e, para a intensidade do broncoespasmo induzido pelo exercício, foram utilizados o cálculo da queda percentual máxima do volume expiratório forçado no primeiro segundo e a área acima da curva. A análise dos dados foi realizada pelo teste U Mann-Whitney e pela ANOVA de Friedman, seguido do teste de Wilcoxon (padolescentes obesos. O excesso de peso pode influenciar no aumento da frequência de broncoespasmo induzido pelo exercício em adolescentes não asmáticos, quando

  20. Improved air trapping evaluation in chest computed tomography in children with cystic fibrosis using real-time spirometric monitoring and biofeedback.

    Science.gov (United States)

    Kongstad, Thomas; Buchvald, Frederik F; Green, Kent; Lindblad, Anders; Robinson, Terry E; Nielsen, Kim G

    2013-12-01

    The quality of chest Computed Tomography (CT) images in children is dependent upon a sufficient breath hold during CT scanning. This study evaluates the influence of spirometric breath hold monitoring with biofeedback software on inspiratory and expiratory chest CT lung density measures, and on trapped air (TA) scoring in children with cystic fibrosis (CF). This is important because TA is an important component of early and progressive CF lung disease. A cross sectional comparison study was completed for chest CT imaging in two cohorts of CF children with comparable disease severity, using spirometric breath hold monitoring and biofeedback software (Copenhagen (COP)) or unmonitored breath hold manoeuvres (Gothenburg (GOT)). Inspiratory-expiratory lung density differences were calculated, and TA was scored to assess the difference between the two cohorts. Eighty-four chest CTs were evaluated. Mean (95%CI) change in inspiratory-expiratory lung density differences was 436 Hounsfield Units (HU) (408 to 464) in the COP cohort with spirometric breath hold monitoring versus 229 HU (188 to 269) in the GOT cohort with unmonitored breath hold manoeuvres (pchildren with comparable CF lung disease, spirometric breath hold monitoring during examination yielded a large difference in lung volume between inhalation and exhalation, and allowed for a significantly greater measured change in lung density and TA score, compared to unmonitored breath hold maneuvers. This has implications to the clinical use of chest CT, especially in children with early CF lung disease. Copyright © 2013 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  1. FEV1 is a better predictor of mortality than FVC: the PLATINO cohort study.

    Directory of Open Access Journals (Sweden)

    Ana Maria B Menezes

    Full Text Available To determine whether the presence of chronic obstructive lung disease (COPD and reduction of lung function parameters were predictors of mortality in a cohort.Population based cohorts were followed in Montevideo, Santiago and Sao Paulo during 5, 6 and 9 years, respectively. Outcomes included all-cause, cardiovascular, respiratory and cancer mortality; exposures were COPD, forced expiratory volume in one second (FEV1 and forced vital capacity (FVC. Cox regression was used for analyses. Sensitivity, specificity, positive and negative predictive values, receiver operator characteristics curves and Youden's index were calculated.Main causes of death were cardiovascular, respiratory and cancer. Baseline COPD was associated with overall mortality (HR = 1.43 for FEV1/FVCFVC was not associated with overall mortality. For most COPD criteria sensitivity was low and specificity high. The area under the curve for FEV1 was greater than for FVC for overall and cardiovascular mortality.COPD and low FEV1 are important predictors for overall and cardiovascular mortality in Latin America.

  2. FEV1 is a better predictor of mortality than FVC: the PLATINO cohort study.

    Science.gov (United States)

    Menezes, Ana Maria B; Pérez-Padilla, Rogelio; Wehrmeister, Fernando César; Lopez-Varela, Maria Victorina; Muiño, Adriana; Valdivia, Gonzalo; Lisboa, Carmen; Jardim, José Roberto B; de Oca, Maria Montes; Talamo, Carlos; Bielemann, Renata; Gazzotti, Mariana; Laurenti, Ruy; Celli, Bartolomé; Victora, Cesar G

    2014-01-01

    To determine whether the presence of chronic obstructive lung disease (COPD) and reduction of lung function parameters were predictors of mortality in a cohort. Population based cohorts were followed in Montevideo, Santiago and Sao Paulo during 5, 6 and 9 years, respectively. Outcomes included all-cause, cardiovascular, respiratory and cancer mortality; exposures were COPD, forced expiratory volume in one second (FEV1) and forced vital capacity (FVC). Cox regression was used for analyses. Sensitivity, specificity, positive and negative predictive values, receiver operator characteristics curves and Youden's index were calculated. Main causes of death were cardiovascular, respiratory and cancer. Baseline COPD was associated with overall mortality (HR = 1.43 for FEV1/FVCFVC was not associated with overall mortality. For most COPD criteria sensitivity was low and specificity high. The area under the curve for FEV1 was greater than for FVC for overall and cardiovascular mortality. COPD and low FEV1 are important predictors for overall and cardiovascular mortality in Latin America.

  3. Asymptomatic tracheal MALT lymphoma discovered on spirometric findings presenting with elevated respiratory resistance.

    Science.gov (United States)

    Kadota, Naoki; Shinohara, Tsutomu; Machida, Hisanori; Nakanishi, Hirofumi; Suehiro, Fumie; Toda, Hiroko; Yoshino, Tadashi; Ogushi, Fumitaka

    2015-06-06

    Central airway obstruction (CAO) may be caused by various etiologies. However, conventional chest X-rays are rarely diagnostic for patients with CAO. We here described a 64-year-old asymptomatic female with tracheal mucosa-associated lymphoid tissue lymphoma discovered on spirometric findings during a complete physical examination. The plateau of forced expiratory flow was consistent with CAO. A decreased peak expiratory flow rate was noted at least 3 years before the diagnosis, and was attributed to an insufficient effort by the patient. Impulse oscillometric measurements, which were taken during quiet breathing and were effort-independent, suggested elevated respiratory resistance. These abnormalities completely disappeared after radiation therapy. The addition of impulse oscillometry to spirometry may be useful for screening CAO in routine health examinations.

  4. The Short-Term Effect of Chest Physiotherapy on Spirometric Indices in Chemical Warfare Victims Exposed to Mustard Gas

    Directory of Open Access Journals (Sweden)

    A Abedi

    2008-12-01

    Full Text Available ABCTRACT Introduction & Objective: Chronic respiratory diseases are the most prevalent late sequels of sulfur mustard gas injury among Iranian chemical warfare victims. Chest physiotherapy is one of the useful methods in care, cure and infection prevention of these patients. The aim of this study was to determine the short-term effect of chest physiotherapy on spirometric indices in chemical warfare victims exposed to sulfur mustard gas. Materials & Methods: In this study, 27 of the chemical warfare victims with respiratory diseases were selected. Chest physiotherapy including postural drainage percussion and vibration were used in four positions for all patients. Pulmonary function test (PFT was obtained before (baseline, immediately and 20 minute after the chest physiotherapy. The SPSS software was used for the data analysis of the collected data. Results: Results of this study showed the significant effect (p<0.01 of chest physiotherapy upon forced expiratory volume in first second (FEV1 (baseline mean, 44.19 immediately after intervention mean 47.3 and 20 minute after intervention mean 48.3 and forced vital capacity (FVC (baseline mean, 69.37 immediately after intervention mean, 73.67 20 minute after intervention 75.74. Chest physiotherapy had significant effect (p<0.01 in asthmatic bronchitis group and also had significant effect (p<0.05 in both severe and moderate groups. Conclusion: Chest physiotherapy was able to improve pulmonary function test indices in chemical warfare victims suffering from respiratory problems. The effect on asthmatic bronchitis group, as well as both severe and moderate groups, was significant.

  5. WE-DE-209-03: Spirometric Motion Management System

    Energy Technology Data Exchange (ETDEWEB)

    Hadley, S. [The University of Michigan (United States)

    2016-06-15

    Breast radiation therapy is associated with some risk of lung toxicity as well as cardiac toxicity for left-sided cases. Radiation doses to the lung and heart can be reduced by using the deep inspiration breath hold (DIBH) technique, in which the patient is simulated and treated during the deep inspiration phase of the breathing cycle. During DIBH, the heart is usually displaced posteriorly, inferiorly, and to the right, effectively expanding the distance between the heart and the breast/chest wall. As a result, the distance between the medial treatment field border and heart/lung is increased. Also, in a majority of DIBH patients, the air drawn into the thoracic cavity increases the total lung volume. The DIBH was discussed by an AAPM Task Group 10 years ago in the AAPM TG 76 report. However, DIBH is still not the standard of care in many clinics, which may be partially due to challenges associated with its implementation. Therefore, this seccion will focus primarily on how to clinically implement four different DIBH techniques: (1) Active Breathing Control, (2) Spirometric Motion Management, (3) 3D Surface Image-Guided, and (4) Self-held Breath Control with Respiratory Monitoring and Feedback Guidance. Learning Objectives: Describe the physical displacement of the heart and the change in lung volume during DIBH and discuss dosimetric consequences of those changes. Provide an overview of the technical aspects. Describe work flow for patient simulation and treatment. Give an overview of commissioning and routine. Provide practical tips for clinical implementation.

  6. WE-DE-209-03: Spirometric Motion Management System

    International Nuclear Information System (INIS)

    Hadley, S.

    2016-01-01

    Breast radiation therapy is associated with some risk of lung toxicity as well as cardiac toxicity for left-sided cases. Radiation doses to the lung and heart can be reduced by using the deep inspiration breath hold (DIBH) technique, in which the patient is simulated and treated during the deep inspiration phase of the breathing cycle. During DIBH, the heart is usually displaced posteriorly, inferiorly, and to the right, effectively expanding the distance between the heart and the breast/chest wall. As a result, the distance between the medial treatment field border and heart/lung is increased. Also, in a majority of DIBH patients, the air drawn into the thoracic cavity increases the total lung volume. The DIBH was discussed by an AAPM Task Group 10 years ago in the AAPM TG 76 report. However, DIBH is still not the standard of care in many clinics, which may be partially due to challenges associated with its implementation. Therefore, this seccion will focus primarily on how to clinically implement four different DIBH techniques: (1) Active Breathing Control, (2) Spirometric Motion Management, (3) 3D Surface Image-Guided, and (4) Self-held Breath Control with Respiratory Monitoring and Feedback Guidance. Learning Objectives: Describe the physical displacement of the heart and the change in lung volume during DIBH and discuss dosimetric consequences of those changes. Provide an overview of the technical aspects. Describe work flow for patient simulation and treatment. Give an overview of commissioning and routine. Provide practical tips for clinical implementation.

  7. Emergency department spirometric volume and base deficit delineate risk for torso injury in stable patients

    Directory of Open Access Journals (Sweden)

    Sipe Eilynn K

    2004-01-01

    Full Text Available Abstract Background We sought to determine torso injury rates and sensitivities associated with fluid-positive abdominal ultrasound, metabolic acidosis (increased base deficit and lactate, and impaired pulmonary physiology (decreased spirometric volume and PaO2/FiO2. Methods Level I trauma center prospective pilot and post-pilot study (2000–2001 of stable patients. Increased base deficit was 2.5 mmol/L in ethanol-negative and ≥ 3.0 mmol/L in ethanol-positive patients. Decreased PaO2/FiO2 was Results Of 215 patients, 66 (30.7% had a torso injury (abdominal/pelvic injury n = 35 and/or thoracic injury n = 43. Glasgow Coma Scale score was 14.8 ± 0.5 (13–15. Torso injury rates and sensitivities were: abdominal ultrasound negative and normal base deficit, lactate, PaO2/FiO2, and spirometric volume – 0.0% & 0.0%; normal base deficit and normal spirometric volume – 4.2% & 4.5%; chest/abdominal soft tissue injury – 37.8% & 47.0%; increased lactate – 39.7% & 47.0%; increased base deficit – 41.3% & 75.8%; increased base deficit and/or decreased spirometric volume – 43.8% & 95.5%; decreased PaO2/FiO2 – 48.9% & 33.3%; positive abdominal ultrasound – 62.5% & 7.6%; decreased spirometric volume – 73.4% & 71.2%; increased base deficit and decreased spirometric volume – 82.9% & 51.5%. Conclusions Trauma patients with normal base deficit and spirometric volume are unlikely to have a torso injury. Patients with increased base deficit or lactate, decreased spirometric volume, decreased PaO2/FiO2, or positive FAST have substantial risk for torso injury. Increased base deficit and/or decreased spirometric volume are highly sensitive for torso injury. Base deficit and spirometric volume values are readily available and increase or decrease the suspicion for torso injury.

  8. Improved air trapping evaluation in chest computed tomography in children with cystic fibrosis using real-time spirometric monitoring and biofeedback

    DEFF Research Database (Denmark)

    Kongstad, Thomas; Buchvald, Frederik F; Green, Kent

    2013-01-01

    CTs were evaluated. Mean (95%CI) change in inspiratory-expiratory lung density differences was 436 Hounsfield Units (HU) (408 to 464) in the COP cohort with spirometric breath hold monitoring versus 229 HU (188 to 269) in the GOT cohort with unmonitored breath hold manoeuvres (p...BACKGROUND: The quality of chest Computed Tomography (CT) images in children is dependent upon a sufficient breath hold during CT scanning. This study evaluates the influence of spirometric breath hold monitoring with biofeedback software on inspiratory and expiratory chest CT lung density measures......, and on trapped air (TA) scoring in children with cystic fibrosis (CF). This is important because TA is an important component of early and progressive CF lung disease. METHODS: A cross sectional comparison study was completed for chest CT imaging in two cohorts of CF children with comparable disease severity...

  9. Relationship of Muscle Mass Determined by DEXA with Spirometric Results in Healthy Individuals.

    Science.gov (United States)

    Martín Holguera, Rafael; Turrión Nieves, Ana Isabel; Rodríguez Torres, Rosa; Alonso, María Concepción

    2017-07-01

    Muscle mass maybe a determining factor in the variability of spirometry results in individuals of the same sex and age who have similar anthropometric characteristics. The aim of this study was to determine the association between spirometric results from healthy individuals and their muscle mass assessed by dual energy X-ray absorptiometry (DEXA). A sample of 161 women and 144 men, all healthy non-smokers, was studied. Ages ranged from18 to77years. For each subject, spirometry results and total and regional lean mass values obtained by full body DEXA were recorded. A descriptive analysis of the variables and a regression analysis were performed to study the relationship between spirometric variables and lean body mass, correcting for age and body mass index (BMI). In both sexes all muscle mass variables correlated positively and significantly with spirometric variables, and to a greater extent in men. After partial adjustment of correlations by age and BMI, the factor which best explains the spirometric variables is the total lean body mass in men, and trunk lean body mass in women. In men, muscle mass in the lower extremities is most closely associated with spirometric results. In women, it is the muscle mass of the trunk. In both sexes muscle mass mainly affects FEV 1 . Copyright © 2016 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Prediction of Spirometric Forced Expiratory Volume (FEV1) Data Using Support Vector Regression

    Science.gov (United States)

    Kavitha, A.; Sujatha, C. M.; Ramakrishnan, S.

    2010-01-01

    In this work, prediction of forced expiratory volume in 1 second (FEV1) in pulmonary function test is carried out using the spirometer and support vector regression analysis. Pulmonary function data are measured with flow volume spirometer from volunteers (N=175) using a standard data acquisition protocol. The acquired data are then used to predict FEV1. Support vector machines with polynomial kernel function with four different orders were employed to predict the values of FEV1. The performance is evaluated by computing the average prediction accuracy for normal and abnormal cases. Results show that support vector machines are capable of predicting FEV1 in both normal and abnormal cases and the average prediction accuracy for normal subjects was higher than that of abnormal subjects. Accuracy in prediction was found to be high for a regularization constant of C=10. Since FEV1 is the most significant parameter in the analysis of spirometric data, it appears that this method of assessment is useful in diagnosing the pulmonary abnormalities with incomplete data and data with poor recording.

  11. Medidas espirométricas em pessoas eutróficas e obesas nas posições ortostática, sentada e deitada Spirometric values of obese and non-obese subjects on orthostatic, sitting and supine positions

    Directory of Open Access Journals (Sweden)

    Nilsa Cristina Domingos-Benício

    2004-04-01

    Full Text Available OBJETIVO: Alguns autores demonstraram que a obesidade gera restrição pulmonar, levando a uma redução dos volumes pulmonares. Entretanto, ainda existem controvérsias acerca da existência dessa restrição e do possível mecanismo responsável por essa alteração. Frente a isso, esse estudo teve como objetivo avaliar a influência do excesso de peso corporal na espirometria, em três diferentes posições corporais, avaliado pelo Índice de Massa Corpórea (IMC, percentual de gordura e relação cintura/quadril. MÉTODOS: Quarenta e seis universitários sedentários, com idades entre 20 e 40 anos, foram avaliados e distribuídos em cinco grupos, de acordo com o IMC. Os voluntários foram submetidos ao exame físico e à mensuração das pregas cutâneas e da circunferência da cintura e do quadril. CVF, VEF1 e VEF1/CVF foram avaliados em três diferentes posições - sentado, deitado e em pé. RESULTADOS: Quando comparados os valores obtidos e previstos entre os grupos, nenhuma diferença estatisticamente significante foi detectada. Quando comparadas as posições corporais, a posição deitada apresentou valores menores que as posições sentado e em pé (pBACKGROUND: It is possible that obesity could lead to pulmonary restriction with decreasing lung volumes. However, controversies about this restriction and its etiology still exist. Thus, the purpose of this report was to evaluate the effects of body weigh excess on spirometry, on three different body positions, evaluated by Body Mass Index (BMI, percentage of fatness and the ratio of abdominal girth to hip breadth (AG/HB. METHODS: Forty-six sedentary volunteers, with ages between 20 and 40 years, were studied and distributed on five groups, based on BMI. Skin fold thickness and ratio of abdominal girth to hip breadth (AG/HB of the volunteers were measured. FVC, FEV1 and ratio of FEV1 to FVC were measured on three different body positions - sitting, supine and orthostatic positions

  12. Reliability of FEV1/FEV6 to Diagnose Airflow Obstruction Compared with FEV1/FVC: The PLATINO Longitudinal Study

    Science.gov (United States)

    Perez-Padilla, Rogelio; Wehrmeister, Fernando C.; Celli, Bartolome R.; Lopez-Varela, Maria Victorina; Montes de Oca, Maria; Muiño, Adriana; Talamo, Carlos; Jardim, Jose R.; Valdivia, Gonzalo; Lisboa, Carmen; Menezes, Ana Maria B.

    2013-01-01

    QUESTION A 6-second spirometry test is easier than full exhalations. We compared the reliability of the ratio of the Forced expiratory volume in 1 second/Forced expiratory volume in 6 seconds (FEV1/FEV6) to the ratio of the FEV1/Forced vital capacity (FEV1/FVC) for the detection of airway obstruction. METHODS The PLATINO population-based survey in individuals aged 40 years and over designed to estimate the prevalence of post-Bronchodilator airway obstruction repeated for the same study participants after 5–9 years in three Latin-American cities. RESULTS Using the FEV1/FVCFVC correlated strongly with changes in the FET of the tests (R2 0.92) unlike the prevalence based on a low FEV1/FEV6 (R2 = 0.40). CONCLUSION The FEV1/FEV6 is a more reliable index than FEV1/FVC because FVC varies with the duration of the forced exhalation. Reporting FET and FEV1/FEV6FVC-derived indices. PMID:23936297

  13. Reliability of FEV1/FEV6 to diagnose airflow obstruction compared with FEV1/FVC: the PLATINO longitudinal study.

    Directory of Open Access Journals (Sweden)

    Rogelio Perez-Padilla

    Full Text Available QUESTION: A 6-second spirometry test is easier than full exhalations. We compared the reliability of the ratio of the Forced expiratory volume in 1 second/Forced expiratory volume in 6 seconds (FEV1/FEV6 to the ratio of the FEV1/Forced vital capacity (FEV1/FVC for the detection of airway obstruction. METHODS: The PLATINO population-based survey in individuals aged 40 years and over designed to estimate the prevalence of post-Bronchodilator airway obstruction repeated for the same study participants after 5-9 years in three Latin-American cities. RESULTS: Using the FEV1/FVCFVC correlated strongly with changes in the FET of the tests (R(2 0.92 unlike the prevalence based on a low FEV1/FEV6 (R(2 =0.40. CONCLUSION: The FEV1/FEV6 is a more reliable index than FEV1/FVC because FVC varies with the duration of the forced exhalation. Reporting FET and FEV1/FEV6FVC-derived indices.

  14. Relationships of methacholine and adenosine 5'-monophosphate (AMP) responsiveness to the postbronchodilator FEV₁/FVC ratio in children with asthma.

    Science.gov (United States)

    Suh, Dong In; Choi, Sun Hee; Lee, Ju Kyung; Kim, Jin-Tack; Koh, Young Yull

    2011-05-01

    Airway remodeling has been assumed to cause bronchial hyperresponsiveness (BHR). A low postbronchodilator FEV₁/FVC ratio has been suggested to be a functional surrogate marker of airway remodeling in asthma. BHR is commonly assessed by bronchial challenges using direct or indirect stimuli. The aim of this study was to compare BHR to methacholine and adenosine 5'-monophosphate (AMP) with regard to their relationship with a marker of airway remodeling in children with asthma. Methacholine and AMP challenge tests were performed in 129 children with asthma, aged 12 years, and a provocative concentration causing a 20% fall in FEV₁ (PC₂₀) was calculated for each challenge. All subjects also underwent pre- and postbronchodilator spirometry. A postbronchodilator FEV₁/FVC ratio below the lower limits of normal was used as a marker of airway remodeling. A low postbronchodilator FEV₁/FVC ratio was found in 17 subjects (13.2%). These subjects had a significantly lower methacholine PC₂₀ (geometric mean: 0.63 mg/mL, range of 1 SD: 0.17-2.29) than those (n = 112) with a normal postbronchodilator FEV₁/FVC ratio (2.42 mg/mL, 0.57-10.32, p = .000), whereas AMP PC₂₀ was similar between the two groups (22.1 mg/mL, 3.9-125.9 vs. 27.7 mg/mL, 4.2-183.5, p = .231). In the whole group of subjects, methacholine PC₂₀, but not AMP PC₂₀, correlated significantly with the postbronchodilator FEV₁/FVC ratio (r = 0.340, p = .000, and r = 0.056, p = .526, respectively). Our results provide evidence, though indirect, that BHR to methacholine is related to airway remodeling in children with asthma and suggest that BHR to methacholine may be a better marker of airway remodeling than BHR to AMP.

  15. Padrões ventilatórios na espirometria em pacientes adolescentes e adultos com fibrose cística Respiratory patterns in spirometric tests of adolescents and adults with cystic fibrosis

    Directory of Open Access Journals (Sweden)

    Bruna Ziegler

    2009-09-01

    Full Text Available OBJETIVO: Avaliar os padrões dos distúrbios ventilatórios observados na espirometria em pacientes com fibrose cística (FC e suas relações com a gravidade funcional e com o comportamento dos fluxos máximos expiratórios a baixos volumes. MÉTODOS: Estudo transversal e retrospectivo, incluindo pacientes adolescentes e adultos com FC. Todos os pacientes foram submetidos à espirometria. Os pacientes foram classificados como tendo função ventilatória preservada, distúrbio ventilatório obstrutivo (DVO, DVO com CVF reduzida, sugestivo de distúrbio ventilatório restritivo (DVR ou distúrbio ventilatório combinado (DVC. Os fluxos máximos expiratórios a baixos volumes foram avaliados utilizando-se FEF25-75%, FEF75%e FEF75%/CVF. O grupo controle incluiu 65 indivíduos normais, também submetidos à espirometria. RESULTADOS: Foram incluídos 65 pacientes no grupo de estudo: 8 (12,3% com função pulmonar preservada, 18 (27,7% com DVO, 24 (36,9% com DVO com CVF reduzida, 5 (7,7% com padrão sugestivo de DVR e 10 (15,4% com DVC. O VEF1 foi significativamente menor nos grupos DVO com CVF reduzida e DVC, comparados com os outros grupos (p OBJECTIVE: To evaluate spirometric patterns of respiratory disorders and their relationship with functional severity and maximal expiratory flows at low lung volumes in patients with cystic fibrosis (CF. METHODS: A retrospective cross-sectional study including adolescents and adults with CF. All of the patients were submitted to spirometry. Patients were classified as having preserved respiratory function, obstructive lung disease (OLD, OLD with reduced FVC, presumptive restrictive lung disease (RLD or mixed obstructive and restrictive lung disease (MORLD. Maximal expiratory flows at low lung volumes were assessed using FEF25-75%, FEF75% and FEF75%/FVC. We included 65 normal subjects, also submitted to spirometry, as a control group. RESULTS: The study group included 65 patients: 8 (12.3% with preserved lung

  16. Spirometric reference values in urban children in Madagascar: poverty is a risk factor for low lung function.

    Science.gov (United States)

    Wolff, Peter Th; Arison, Lala; Rahajamiakatra, Abel; Raserijaona, Francis; Niggemann, Bodo

    2014-01-01

    Studies about children with respiratory diseases in Africa are impeded by the dearth of reliable data for the vast majority of countries on the continent. This study was conducted to establish representative reference values, therefore allowing a more accurate evaluation of lung function in Malagasy children. One thousand two hundred thirty-six students from three public and five private schools aged 8-12 years were recruited. A total of 1,093 children were healthy, had a valid lung function measurement and were thus deemed evaluable for this study. Lung function data were collected on consecutive days in Antananarivo, Madagascar's capital, using spirometry and a modified International Study of Asthma and Allergies in Childhood (ISAAC) questionnaire. The lung volumes found were substantially lower compared to Caucasian and African equations. The mean Z-score (Stanojevic) for the forced vital capacity (FVC) found was -1.45 and -0.93 for the forced expiratory volume in 1 sec (FEV1) with significant differences between private and public schools (FVC: P = 0.0023, FEV1: P = 0.0004). The equations established for school children in Madagascar's capital Antananarivo showed lung function values were lower than reference values for the same age group seen not only in European, but also in African American and African children. The unique ethnicity of the Malagasy people, which combines Southeast-Asian with substantial African influences, the heavy burden of pollution and poverty may explain these differences. © 2013 Wiley Periodicals, Inc.

  17. Effects of Ramadan Fasting on Spirometric Values and Clinical Symptoms in Asthmatic Patients

    Directory of Open Access Journals (Sweden)

    Abdolreza Norouzy

    2013-07-01

    Full Text Available Introduction: Ramadan is the 9th Islamic lunar month during which Muslims avoid eating and drinking from sunrise to sunset. The effect of Ramadan intermittent fasting on asthma control is controversial. The aim of this study was to investigate the effects of Ramadan fasting on the spirometric variables and clinical symptoms on well-controlled asthmatic patients during Ramadan. Material and Methods: a cohort study was conducted in Mashhad, Khorasan Razavi, Iran. Twenty-nine (19 females and 10 males well-controlled asthmatic patients aged 47 (12 years completed the study. The average duration of fasting was 26.5 days. Assessment of spirometric variables (daily peak expiratory flow, peak expiratory flow variability, peak expiratory flow home monitoring as well as asthma clinical symptoms including dyspnea, cough, wheezing, and chest tightness were carried out. Results: No significant changes in clinical symptoms were reported in asthmatic patients at the end of Ramadan fasting. Among spirometric variables, only peak expiratory flow improved after Ramadan (p <0.05. There was a reduction in the mean peak expiratory flow variability from 13% at the first week of fasting to 10% at the fourth week (p <0.05. Conclusion: In well-controlled asthmatic patients, Ramadan fasting resulted in improvement in peak expiratory flow and peak expiratory flow variability.

  18. Effects of Ramadan fasting on spirometric values and clinical symptoms in asthmatic patients

    Directory of Open Access Journals (Sweden)

    Abdolreza Norouzy

    2013-03-01

    Full Text Available Introduction: Ramadan is the 9th  Islamic lunar month during which Muslims avoid eating and drinking from sunrise to sunset.  The effect of Ramadan intermittent fasting on asthma control is controversial.  The aim of this study was to investigate the effects of Ramadan fasting on the spirometric variables and clinical symptoms on well-controlled asthmatic patients during Ramadan. Material and Methods: a cohort study was conducted in Mashhad, Khorasan Razavi, Iran. Twenty-nine (19 females and 10 males well-controlled asthmatic patients aged 47 (12 years completed the study.  The average duration of fasting was 26.5 days. Assessment of spirometric variables (daily peak expiratory flow, peak expiratory flow variability, peak expiratory flow home monitoring as well as asthma clinical symptoms including dyspnea, cough, wheezing, and chest tightness were carried out. Results: No significant changes in clinical symptoms were reported in asthmatic patients at the end of Ramadan fasting.  Among spirometric variables, only peak expiratory flow improved after Ramadan (p

  19. Ventilation/perfusion SPECT in chronic obstructive pulmonary disease: an evaluation by reference to symptoms, spirometric lung function and emphysema, as assessed with HRCT

    Energy Technology Data Exchange (ETDEWEB)

    Joegi, Jonas; Bajc, Marika [Lund University, Skaane University Hospital, Department of Clinical Physiology, Institution of Clinical Sciences, Lund (Sweden); Ekberg, Marie [Lund University, Skaane University Hospital, Department of Respiratory Medicine and Allergology, Institution of Clinical Sciences, Lund (Sweden); Jonson, Bjoern [Lund University, Department of Clinical Physiology, Institution of Clinical Sciences, Lund (Sweden); Bozovic, Gracijela [Lund University, Skaane University Hospital, Department of Radiology, Institution of Clinical Sciences, Lund (Sweden)

    2011-07-15

    Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation which is not fully reversible. Despite the heterogeneity of COPD, its diagnosis and staging is currently based solely on forced expiratory volume in 1 s (FEV{sub 1}). FEV{sub 1} does not explain the underlying pathophysiology of airflow limitation. The relationship between FEV{sub 1}, symptoms and emphysema extent is weak. Better diagnostic tools are needed to define COPD. Tomographic lung scintigraphy [ventilation/perfusion single photon emission tomography (V/P SPECT)] visualizes regional V and P. In COPD, relations between V/P SPECT, spirometry, high-resolution computed tomography (HRCT) and symptoms have been insufficiently studied. The aim of this study was to investigate how lung function imaging and obstructive disease grading undertaken using V/P SPECT correlate with symptoms, spirometric lung function and degree of emphysema assessed with HRCT in patients with COPD. Thirty patients with stable COPD were evaluated with the Medical Research Council dyspnoea questionnaire (MRC) and the clinical COPD questionnaire (CCQ). Spirometry was performed. The extent of emphysema was assessed using HRCT. V/P SPECT was used to assess V/P patterns, total reduction in lung function and degree of obstructive disease. The total reduction in lung function and degree of obstructive disease, assessed with V/P SPECT, significantly correlated with emphysema extent (r = 0.66-0.69, p < 0.0001) and spirometric lung function (r = 0.62-0.74, p < 0.0005). The correlation between emphysema extent and spirometric lung function was weaker. No correlation between MRC, CCQ and objective measurements was found. V/P SPECT is sensitive to early changes in COPD. V/P SPECT also has the possibility to identify comorbid disease. V/P SPECT findings show a significant correlation with emphysema extent and spirometric lung function. We therefore recommend that scintigraphic signs of COPD, whenever found, should be

  20. Ventilation/perfusion SPECT in chronic obstructive pulmonary disease: an evaluation by reference to symptoms, spirometric lung function and emphysema, as assessed with HRCT

    International Nuclear Information System (INIS)

    Joegi, Jonas; Bajc, Marika; Ekberg, Marie; Jonson, Bjoern; Bozovic, Gracijela

    2011-01-01

    Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation which is not fully reversible. Despite the heterogeneity of COPD, its diagnosis and staging is currently based solely on forced expiratory volume in 1 s (FEV 1 ). FEV 1 does not explain the underlying pathophysiology of airflow limitation. The relationship between FEV 1 , symptoms and emphysema extent is weak. Better diagnostic tools are needed to define COPD. Tomographic lung scintigraphy [ventilation/perfusion single photon emission tomography (V/P SPECT)] visualizes regional V and P. In COPD, relations between V/P SPECT, spirometry, high-resolution computed tomography (HRCT) and symptoms have been insufficiently studied. The aim of this study was to investigate how lung function imaging and obstructive disease grading undertaken using V/P SPECT correlate with symptoms, spirometric lung function and degree of emphysema assessed with HRCT in patients with COPD. Thirty patients with stable COPD were evaluated with the Medical Research Council dyspnoea questionnaire (MRC) and the clinical COPD questionnaire (CCQ). Spirometry was performed. The extent of emphysema was assessed using HRCT. V/P SPECT was used to assess V/P patterns, total reduction in lung function and degree of obstructive disease. The total reduction in lung function and degree of obstructive disease, assessed with V/P SPECT, significantly correlated with emphysema extent (r = 0.66-0.69, p < 0.0001) and spirometric lung function (r = 0.62-0.74, p < 0.0005). The correlation between emphysema extent and spirometric lung function was weaker. No correlation between MRC, CCQ and objective measurements was found. V/P SPECT is sensitive to early changes in COPD. V/P SPECT also has the possibility to identify comorbid disease. V/P SPECT findings show a significant correlation with emphysema extent and spirometric lung function. We therefore recommend that scintigraphic signs of COPD, whenever found, should be reported. V

  1. Subjects with Discordant Airways Obstruction: Lost between Spirometric Definitions of COPD

    Directory of Open Access Journals (Sweden)

    Bernd Lamprecht

    2011-01-01

    Full Text Available Background. Since the FEV1/FVC ratio declines with age, using the fixed ratio of 0.70 leads to overdiagnosis of COPD in older populations and underdiagnosis among young adults. Objective. To evaluate whether discordant obstructive cases (FEV1/FVC < 0.70 but ≥LLN are a healthy population or have clinical features that would place them at increased risk. Methods. We used post-bronchodilator spirometry data from the population-based Austrian Burden of Obstructive Lung Disease (BOLD study. Those with post-bronchodilator FEV1/FVC ratio FVC ratio ≥LLN but <0.70 were defined as discordant obstructive cases. Results. Discordant obstructive cases were more likely to be older, male and never-smokers. Additionally they had less respiratory symptoms and less severe impairment of FEV1. However, discordant obstructive cases reported significantly more often a diagnosis of heart disease than subjects with normal lung function (27.2% vs 7.3%, P=.015. Conclusion. The clinical profile of discordant obstructive cases includes potentially important comorbid disease.

  2. Fibrose cística em adultos: aspectos clínicos e espirométricos Cystic fibrosis in adults clinical and spirometric aspects

    Directory of Open Access Journals (Sweden)

    Antônio Carlos M. Lemos

    2004-02-01

    data of patients with CF diagnosed in adulthood (over 16 years of age in Bahia, Brazil. METHODS: Twenty-eight patients with cystic fibrosis diagnosed in adulthood were evaluated at the Reference Center of Cystic Fibrosis of the state of Bahia. Variables of interest were age, gender, race, body mass index (BMI, sputum culture, presence of sinusitis and bronchiectasis, spirometric tests with the best values performed for forced expiratory volume in the first second (% FEV1, forced vital capacity (FVC and response to bronchodilators. RESULTS: Mean age of diagnosis was 31.1 ± 12.4 years. Of the patients, 53.4% were black and mulattos and the mean BMI was 18.7 ± 3.0 kg/m2. P. aeruginosa was present in 12 (43% of the total patients. The mean percentages ± SD of FVC and FEV1 were 58.9 ± 21.6% and 44.1 ± 23%, respectively. In the group of patients with presence of P. aeruginosa in the sputum cultures mean of the spirometry parameters were lower than those of the P. aeruginosa-free group. However, this difference achieved a statistically significant difference (p = 0.0007 only in FVC. CONCLUSIONS: In agreement with many authors, this study strengthen the point of view that CF must be investigated in patients with recurrent infections, sinusitis and bronchiectasis even in adulthood. Values of the percentages of FVC and FEV1 in relation to those foreseen were lower in patients bearers of P.aeruginosa thereby showing a higher deterioration of the pulmonary function.

  3. Dependent lung opacity at thin-section CT: evaluation by spirometrically-gated CT of the influence of lung volume

    International Nuclear Information System (INIS)

    Lee, Ki Nam; Yoon, Seong Kuk; Sohn, Choon Hee; Choi, Pil Jo; Webb, W. Richard

    2002-01-01

    To evaluate the influence of lung volume on dependent lung opacity seen at thin-section CT. In thirteen healthy volunteers, thin-section CT scans were performed at three levels (upper, mid, and lower portion of the lung) and at different lung volumes (10, 30, 50, and 100% vital capacity), using spirometric gated CT. Using a three-point scale, two radiologists determined whether dependent opacity was present, and estimated its degree. Regional lung attenuation at a level 2 cm above the diaphragm was determined using semiautomatic segmentation, and the diameter of a branch of the right lower posterior basal segmental artery was measured at each different vital capacity. At all three anatomic levels, dependent opacity occurred significantly more often at lower vital capacities (10, 30%) than at 100% vital capacity (p = 0.001). Visually estimated dependent opacity was significantly related to regional lung attenuation (p < 0.0001), which in dependent areas progressively increased as vital capacity decreased (p < 0.0001). The presence of dependent opacity and regional lung attenuation of a dependent area correlated significantly with increased diameter of a segmental arterial branch (r = 0.493 and p = 0.0002; r = 0.486 and p 0.0003, respectively). Visual estimation and CT measurements of dependent opacity obtained by semiautomatic segmentation are significantly influenced by lung volume and are related to vascular diameter

  4. FEV 1 , FVC, FEV 1 /FVVC as predictors of rhinitis among saw mill ...

    African Journals Online (AJOL)

    Data on sociodemographic variables, symptoms of rhinitis, etc was obtained using a modified semi structured British medical research council questionnaire while respiratory function data was measured using a spirometry. Result: A total of 400 responds comprising of 200 saw mill workers and 200 controls participated in ...

  5. Validity and interpretation of spirometric recordings to diagnose COPD in UK primary care

    Directory of Open Access Journals (Sweden)

    Rothnie KJ

    2017-06-01

    Full Text Available Kieran J Rothnie,1,2 Joht S Chandan,3,4 Harry G Goss,4,5 Hana Müllerová,6 Jennifer K Quint1,2 1Respiratory Epidemiology, Occupational Medicine and Public Health, National Heart and Lung Institute, Imperial College London, 2Faculty of Epidemiology and Population Health, London School of Hygiene and Tropical Medicine, London, 3Queen Elizabeth Hospital Birmingham, University Hospitals Birmingham, Birmingham, 4Medical School, Faculty of Medical Sciences, University College London, 5Jersey General Hospital, St Helier, Jersey, 6Respiratory Epidemiology, GlaxoSmithKline R&D, Uxbridge, UK Background: The diagnosis of COPD is dependent upon clinical judgment and confirmation of the presence of airflow obstruction using spirometry. Spirometry is now routinely available; however, spirometry incorrectly performed or interpreted can lead to misdiagnosis. We aimed to determine whether spirometry undertaken in primary care for patients suspected to have COPD was of sufficient quality and whether their spirometry was correctly interpreted.Methods: Two chest physicians re-read all spirometric readings for both quality of the procedure and interpretation, received as a part of COPD validation studies using data from the Clinical Practice Research Datalink (CPRD. We then used logistic regression to investigate predictors of correct interpretation.Results: Spirometry traces were obtained for 306 patients, of which 221 (72.2% were conducted in primary care. Of those conducted in primary care, 98.6% (n=218 of spirometry traces were of adequate quality. Of those traces that were of adequate quality and conducted in primary care, and in whom a general practitioner (GP diagnosis of COPD had been made, 72.5% (n=218 were consistent with obstruction. Historical records for asthma diagnosis significantly decreased odds of correct interpretation.Conclusion: The quality of the spirometry procedure undertaken in primary care is high. However, this was not reflected in the

  6. Comparison of the Influence of Different Rehabilitation Programmes on Clinical, Spirometric and Spiroergometric Parameters in Patients with Multiple Sclerosis

    Czech Academy of Sciences Publication Activity Database

    Řasová, K.; Havrdová, E.; Brandejský, P.; Zálišová, M.; Foubíková, B.; Martinková, Patrícia

    2006-01-01

    Roč. 12, č. 2 (2006), s. 227-234 ISSN 1352-4585 Source of funding: V - iné verejné zdroje Keywords : aerobic training * fatigue * multiple sclerosis * neurorehabilitation * spirometric and spiroergometric parameters Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 2.773, year: 2006

  7. SPIROMETRIC RESPONSE TO OZONE (O3) IN YOUNG ADULTS AS A FUNCTION OF BODY MAASS INDEX (BMI)

    Science.gov (United States)

    Recent studies in murine models of obesity have shown enhanced responsiveness to ozone in obese vs. lean mice. To assess whether previous human ozone exposure data from our laboratory support an effect of BMI on the spirometric response to ozone we analyzed the post-O3 percent de...

  8. Spirometrically gated /sup 133/Xe ventilation imaging and phase analysis for assessment of regional lung function

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Tomio (Kanto Teishin Hospital, Tokyo (Japan))

    1984-10-01

    The purpose of this study is to develop the technique of performing spirometrically gated /sup 133/Xe ventilation imaging and to evaluate its clinical usefulness for the assessment of regional ventilatory function in various lung diseases. Patients rebreathed /sup 133/Xe gas through the system with constant rates signaled by a metronome. The trigger signals from the patients were recorded in a minicomputer for 60 respiratory cycles simultaneously with posterior lung images. Functional images (phase analysis images) indicating phase and amplitude of regional ventilation were constructed by the first harmonic Fourier analysis. Materials included 13 normal volunteers and patients with COPD (24), lung cancer (5), pulmonary embolism (4) and others (20). In normal controls, phase analysis images before respiratory motion correction revealed gradual decrease in amplitude from base to apex with uniform phase distribution. The amplitude and phase distribution after respiratory motion correction became even more uniform. In patients with COPD, phase analysis images showed asymmetrical and irregular amplitude distribution with non-uniform phase distribution. The standard deviation (S.D.) of phase histogram correlated well with FEVsub(1.0)% (r=0.71, p < 0.001) and down slope of flow-volume curve (r=0.55, p < 0.001), and less prominently with %VC (r=0.42, p < 0.01). Mean S.D. in patients with COPD (12.3 +- 6.5 degree, mean+-1 s.d.) was significantly larger than in normal controls (6.3 +- 1.5). Amplitude profile curve analysis revealed 83% sensitivity for the detection of abnormal spirometric respiratory function test. Data aquisition and processing of present method are rapid and easy to perform. The phase analysis of the gated ventilation images should prove useful in the clinical evaluation of patients with uneven ventilation such as COPD.

  9. Spirometrically gated 133Xe ventilation imaging and phase analysis for assessment of regional lung function

    International Nuclear Information System (INIS)

    Inoue, Tomio

    1984-01-01

    The purpose of this study is to develop the technique of performing spirometrically gated 133 Xe ventilation imaging and to evaluate its clinical usefulness for the assessmentof regional ventilatory function in various lung diseases. Patients rebreathe d 133 Xe gas through the system with constant rates signaled by a metronom. The trigger signals from the patients were recorded in a minicomputer for 60 respiratory cycles simultaneously with posterior lung images. Functional images (phase analysis images) indicating phase and amplitude of regional ventilation were constructed by the first harmonic Fourier analysis. Materials included 13 normal volunteers and patients with COPD (24), lung cancer (5), pulmonary embolism (4) and others (20). In normal controls, phase analysis images before respiratory motion correction revealed gradual decrease in amplitude from base to apex with uniform phase distribution. The amplitude and phase distribution after respiratory motion correction became even more uniform. In patients with COPD, phase analysis images showed asymmetrical and irregular amplitude distribution with non-uniform phase distribution. The standard deviation (S.D.) of phase histogram correlated well with FEVsub(1.0)% (r=0.71, p<0.001) and down slope of flowvolume curve (r=0.55, p<0.001), and less prominently with %VC (r=0.42, p<0.01). Mean S.D. in patients with COPD (12.3+-6.5 degree, mean+-1 s.d.) was significantly larger than in normal controls (6.3+-1.5). Amplitude profile curve analysis revealed 83% sensitivity for the detection of abnormal spirometric respiratory function test. Data aquisition and processing of present method are rapid and easy to perform. The phase analysis of the gated ventilation images should prove useful in the clinical evaluation of patients with uneven ventilation such as COPD. (J.P.N.)

  10. Spirometric assessment of lung transplant patients: one year follow-up

    Directory of Open Access Journals (Sweden)

    Paulo M. Pêgo-Fernandes

    2009-06-01

    Full Text Available OBJECTIVE: The purpose of this study was to compare spirometry data between patients who underwent single-lung or double-lung transplantation the first year after transplantation. INTRODUCTION: Lung transplantation, which was initially described as an experimental method in 1963, has become a therapeutic option for patients with advanced pulmonary diseases due to improvements in organ conservation, surgical technique, immunosuppressive therapy and treatment of post-operative infections. METHODS: We retrospectively reviewed the records of the 39 patients who received lung transplantation in our institution between August 2003 and August 2006. Twenty-nine patients survived one year post-transplantation, and all of them were followed. RESULTS: The increase in lung function in the double-lung transplant group was more substantial than that of the single-lung transplant group, exhibiting a statistical difference from the 1st month in both the forced expiratory volume in one second (FEV1 and the forced vital capacity (FVC in comparison to the pre-transplant values (p <0.05. Comparison between double-lung transplant and single lung-transplant groups of emphysema patients demonstrated a significant difference in lung function beginning in the 3rd month after transplantation. DISCUSSION: The analyses of the whole group of transplant recipients and the sub-group of emphysema patients suggest the superiority of bilateral transplant over the unilateral alternative. Although the pre-transplant values of lung function were worse in the double-lung group, this difference was no longer significant in the subsequent months after surgery. CONCLUSION: Although both groups demonstrated functional improvement after transplantation, there was a clear tendency to greater improvement in FVC and FEV1 in the bilateral transplant group. Among our subjects, double-lung transplantation improved lung function.

  11. [Estimation of volume of pleural fluid and its impact on spirometrical parameters].

    Science.gov (United States)

    Karwat, Krzysztof; Przybyłowski, Tadeusz; Bielicki, Piotr; Hildebrand, Katarzyna; Nowacka-Mazurek, Magdalena; Nasiłowski, Jacek; Rubinsztajn, Renata; Chazan, Ryszarda

    2014-03-01

    In the course of various diseases, there is an accumulation of fluid in the pleural cavities. Pleural fluid accumulation causes thoracic volume expansion and reduction of volume lungs, leading to formation of restrictive disorders. The aim of the study was to estimate the volume of pleural fluid by ultrasonography and to search for the relationship between pleural fluid volume and spirometrical parameters. The study involved 46 patients (26 men, 20 women) aged 65.7 +/- 14 years with pleural effusions who underwent thoracentesis. Thoracentesis was preceded by ultrasonography of the pleura, spirometry test and plethysmography. The volume of the pleural fluid was calculated with the Goecke' and Schwerk' (GS) or Padykuła (P) equations. The obtained values were compared with the actual evacuated volume. The median volume of the removed pleural fluid was 950 ml. Both underestimated the evacuated volume (the median volume 539 ml for GS and 648 ml for P, respectively). Pleural fluid removal resulted in a statistically significant improvement in VC (increase 0.20 +/- 0.35 ; p Pleural fluid removal causes a significant improvement in lung function parameters. The analyzed equations for fluid volume calculation do not correlate with the actual volume.

  12. The measurement of 99mTc-DTPA pulmonary clearance in normals, asymptomatic smokers and diabetic patients

    International Nuclear Information System (INIS)

    Kim, In Ju; Kim, Seong Jang; Kim, Yong Ki; Kim, Yun Seong; Lee, Min Ki; Park, Soon Kew

    1998-01-01

    We measured pulmonary epithelial permeability by 99m Tc-DTPA radioaerosol clearance in patients with diabetes and correlated with the presence of microangiopathy to understand the pathophysiology of pulmonary microangiopathy and evaluate 99m Tc-DTPA radioaerosol clearance as a diagnostic test to assess pulmonary microangiopathy. We performed 99m Tc-DTPA radioaerosol scan in 10 normal subjects, 10 asymptomatic smokers, 20 diabetic patients without history of smoking (10 with microangiopathy, 10 without microangiopathy). 99m Tc-DTPA clearance half-time (T 1/2 ) was calculated, then compared with the result of chest radiography and pulmonary function test. Chest radiography and pulmonary function test were normal in all subjects. There were no significant difference of clinical or laboratory characteristics between these groups except age. The diabetic patients with microangiophaty were significantly older (p 1/2 of normal subjects and asymptomatic smokers were significantly different (65.2±23.7 min vs 39.6±9.8 min, p 1/2 was 90.5±46.5 min and significantly delayed when compared with those of normals and asymptomatic smokers (p 1/2 of diabetic patients without microangiopathy, 70.0±12.7 min, was not significantly different from those of normals or asymptomatic smokers (p>0.05). No significant correlation was found between the T 1/2 and spirometric parameters including DLco, FVC, FEV 1 , FEV 1 /FVC (%) and FEF 25-75% in all subjects, and between the T 1/2 and duration of diabetes in diabetic patients. Eventhough the influence of age can't be excluded, delayed 99m Tc-DTPA clearance half-time (T 1/2 ) in diabetic patients with microangiopathy indicates decreased pulmonary capillary permeability as one of the pathophysiologic results of pulmonary microangiopaththy. Further studies are needed in larger number of age matched control and diabetic patients to evaluate the diagnostic efficacy

  13. Cut-off value of FEV1/FEV6 as a surrogate for FEV1/FVC for detecting airway obstruction in a Korean population

    Directory of Open Access Journals (Sweden)

    Chung KS

    2016-08-01

    Full Text Available Kyung Soo Chung,1,2 Ji Ye Jung,1,2 Moo Suk Park,1,2 Young Sam Kim,1,2 Se Kyu Kim,1,2 Joon Chang,1,2 Joo Han Song1,2 1Division of Pulmonology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea; 2Institute of Chest Disease, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea Background: Forced expiratory volume in 1 second (FEV1/forced expiratory volume in 6 seconds (FEV6 has been proposed as an alternative to FEV1/forced vital capacity (FVC for detecting airway obstruction. A fixed cut-off value for FEV1/FEV6 in a Korean population is lacking. We investigated a fixed cut-off for FEV1/FEV6 as a surrogate for FEV1/FVC for detecting airway obstruction.Materials and methods: We used data obtained in the 5 years of the Fifth and Sixth Korean National Health and Nutrition Examination Survey. A total of 14,978 participants aged ≥40 years who underwent spirometry adequately were the study cohort. “Airway obstruction” was a fixed cut-off FEV1/FVC <70% according to the Global Initiative for Chronic Obstructive Lung Disease guidelines. We also used European Respiratory Society/Global Lung Initiative 2012 equations for the FEV1/FVC lower limit of normal.Results: Among the 14,978 participants (43.5% male, 56.5% female; mean age: 56.9 years for men and 57.0 years for women, 14.0% had obstructive lung function according to a fixed cut-off FEV1/FVC <70%. Optimal FEV1/FEV6 cut-off for predicting FEV1/FVC <70% was 75% using receiver operating characteristic curve analyses (area under receiver operating characteristic curve =0.989, 95% confidence interval 0.987–0.990. This fixed cut-off of FEV1/FEV6 showed 93.8% sensitivity, 94.8% specificity, 74.7% positive predictive value, 98.9% negative predictive value, and 0.8 Cohen’s kappa coefficient. When compared with FEV1/FVC < lower limit of normal, FEV1/FEV6 <75% tended to over-diagnose airflow limitation (just like a fixed cut

  14. Childhood asthma and spirometric indices are associated with polymorphic markers of two vitamin D 25-hydroxylase genes.

    Science.gov (United States)

    Leung, Ting Fan; Wang, Susan Shuxin; Tang, Man Fung; Kong, Alice Pik-Shan; Sy, Hing Yee; Hon, Kam Lun; Chan, Juliana Chung-ngor; Wong, Gary Wing-kin

    2015-06-01

    Polymorphic markers of vitamin D pathway genes have been associated with asthma traits in different White populations. This study investigated the relationship between asthma phenotypes and single nucleotide polymorphisms (SNPs) of vitamin D receptor (VDR), vitamin D binding protein (GC), two 25-hydroxylases (CYP2R1 and CYP27A1), and 1α-hydroxylase (CYP27B1) in Hong Kong Chinese children. 23 SNPs of the five vitamin D pathway genes were successfully genotyped in 914 asthmatic children and 1231 non-allergic controls. Genotypic and haplotypic associations with asthma phenotypes (diagnosis, spirometric indices, total IgE, and eosinophil percentage) were analyzed by multivariate regression. Generalized multifactor dimensionality reduction was used to detect epistatic interactions between SNPs for asthma phenotypes. Several SNPs of CYP27A1, CYP27B1, GC, and CYP2R1 were associated with asthma or spirometric indices, although only the association between FEV1 and CYP2R1 rs7935792 passed Bonferroni correction (p = 2.73 × 10(-4) ). Patients with CC genotype of rs7935792 had higher FEV1 than those with the other two genotypes. Asthma was also associated with TT haplotype of CYP27A1 and AGGATA haplotype of CYP2R1 (p = 0.021 and 0.024, respectively). Besides, strong association was found between FEV1 and GATAG of CYP2R1 (β = 13.37, p = 4.83 × 10(-4) ). GMDR failed to identify any 2-locus to 4-locus interaction that modulated asthma or spirometric indices. Several SNPs and haplotypes of CYP2R1 are associated with asthma diagnosis and FEV1 in children. Asthma is also modestly associated with a CYP27A1 haplotype. These two 25-hydroxylase genes may be genetic determinants for asthma phenotypes in children. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Asynchrony in respiratory movements between the pulmonary lobes in patients with COPD: continuous measurement of lung density by 4-dimensional dynamic-ventilation CT

    Directory of Open Access Journals (Sweden)

    Yamashiro T

    2017-07-01

    Full Text Available Tsuneo Yamashiro,1 Hiroshi Moriya,2 Shin Matsuoka,3 Yukihiro Nagatani,4 Maho Tsubakimoto,1 Nanae Tsuchiya,1 Sadayuki Murayama1 On behalf of the ACTIve Study Group 1Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Nishihara, Okinawa, Japan; 2Department of Radiology, Ohara General Hospital, Fukushima-City, Fukushima, Japan; 3Department of Radiology, St Marianna University School of Medicine, Kawasaki, Kanagawa, Japan; 4Department of Radiology, Shiga University of Medical Science, Otsu, Shiga, Japan Purpose: Four-dimensional dynamic-ventilation CT imaging demonstrates continuous movement of the lung. The aim of this study was to assess the correlation between interlobar synchrony in lung density and spirometric values in COPD patients and smokers, by measuring the continuous changes in lung density during respiration on the dynamic-ventilation CT. Materials and methods: Thirty-two smokers, including ten with COPD, underwent dynamic-ventilation CT during free breathing. CT data were continuously reconstructed every 0.5 sec. Mean lung density (MLD of the five lobes (right upper [RU], right middle [RM], right lower [RL], left upper [LU], and left lower [LL] was continuously measured by commercially available software using a fixed volume of volume of interest which was placed and tracked on a single designated point in each lobe. Concordance between the MLD time curves of six pairs of lung lobes (RU-RL, RU-RM, RM-RL, LU-LL, RU-LU, and RL-LL lobes was expressed by cross-correlation coefficients. The relationship between these cross-correlation coefficients and the forced expiratory volume in one second/forced vital capacity (FEV1.0/FVC values was assessed by Spearman rank correlation analysis. Results: In all six pairs of the pulmonary lobes, the cross-correlation coefficients of the two MLD curves were significantly positively correlated with FEV1.0/FVC (ρ =0.60–0.73, P<0.001. The mean value of the six

  16. Whole-lung volume and density in spirometrically-gated inspiratory and expiratory CT in systemic sclerosis: correlation with static volumes at pulmonary function tests.

    Science.gov (United States)

    Camiciottoli, G; Diciotti, S; Bartolucci, M; Orlandi, I; Bigazzi, F; Matucci-Cerinic, M; Pistolesi, M; Mascalchi, M

    2013-03-01

    Spiral low-dose computed tomography (LDCT) permits to measure whole-lung volume and density in a single breath-hold. To evaluate the agreement between static lung volumes measured with LDCT and pulmonary function test (PFT) and the correlation between the LDCT volumes and lung density in restrictive lung disease. Patients with Systemic Sclerosis (SSc) with (n = 24) and without (n = 16) pulmonary involvement on sequential thin-section CT and patients with chronic obstructive pulmonary disease (COPD)(n = 29) underwent spirometrically-gated LDCT at 90% and 10% of vital capacity to measure inspiratory and expiratory lung volumes and mean lung attenuation (MLA). Total lung capacity and residual volume were measured the same day of CT. Inspiratory [95% limits of agreement (95% LoA)--43.8% and 39.2%] and expiratory (95% LoA -45.8% and 37.1%) lung volumes measured on LDCT and PFT showed poor agreement in SSc patients with pulmonary involvement, whereas they were in substantial agreement (inspiratory 95% LoA -14.1% and 16.1%; expiratory 95% LoA -13.5% and 23%) in SSc patients without pulmonary involvement and in inspiratory scans only (95% LoA -23.1% and 20.9%) of COPD patients. Inspiratory and expiratory LDCT volumes, MLA and their deltas differentiated both SSc patients with or without pulmonary involvement from COPD patients. LDCT lung volumes and density were not correlated in SSc patients with pulmonary involvement, whereas they did correlate in SSc without pulmonary involvement and in COPD patients. In restrictive lung disease due to SSc there is poor agreement between static lung volumes measured using LDCT and PFT and the relationship between volume and density values on CT is altered.

  17. A randomized study of contingency management and spirometric lung age for motivating smoking cessation among injection drug users.

    Science.gov (United States)

    Drummond, Michael B; Astemborski, Jacquie; Lambert, Allison A; Goldberg, Scott; Stitzer, Maxine L; Merlo, Christian A; Rand, Cynthia S; Wise, Robert A; Kirk, Gregory D

    2014-07-28

    Even after quitting illicit drugs, tobacco abuse remains a major cause of morbidity and mortality in former injection drug users. An important unmet need in this population is to have effective interventions that can be used in the context of community based care. Contingency management, where a patient receives a monetary incentive for healthy behavior choices, and incorporation of individual counseling regarding spirometric "lung age" (the age of an average healthy individual with similar spirometry) have been shown to improve cessation rates in some populations. The efficacy of these interventions on improving smoking cessation rates has not been studied among current and former injection drug users. In a randomized, factorial design study, we recruited 100 active smokers from an ongoing cohort study of current and former injection drug users to assess the impact of contingency management and spirometric lung age on smoking cessation. The primary outcome was 6-month biologically-confirmed smoking cessation comparing contingency management, spirometric lung age or both to usual care. Secondary outcomes included differences in self-reported and biologically-confirmed cessation at interim visits, number of visits attended and quit attempts, smoking rates at interim visits, and changes in Fagerstrom score and self-efficacy. Six-month biologically-confirmed smoking cessations rates were 4% usual care, 0% lung age, 14% contingency management and 0% for combined lung age and contingency management (p = 0.13). There were no differences in secondary endpoints comparing the four interventions or when pooling the lung age groups. Comparing contingency management to non-contingency management, 6-month cessation rates were not different (7% vs. 2%; p = 0.36), but total number of visits with exhaled carbon monoxide-confirmed abstinence were higher for contingency management than non-contingency management participants (0.38 vs. 0.06; p = 0.03), and more contingency management

  18. Optimal clinical time for reliable measurement of transcutaneous CO2 with ear probes: counterbalancing overshoot and the vasodilatation effect.

    Science.gov (United States)

    Domingo, Christian; Canturri, Elisa; Moreno, Amalia; Espuelas, Humildad; Vigil, Laura; Luján, Manel

    2010-01-01

    To determine the optimal clinical reading time for the transcutaneous measurement of oxygen saturation (SpO(2)) and transcutaneous CO(2) (TcPCO(2)) in awake spontaneously breathing individuals, considering the overshoot phenomenon (transient overestimation of arterial PaCO(2)). EXPERIMENTAL SECTION: Observational study of 91 (75 men) individuals undergoing forced spirometry, measurement of SpO(2) and TcPCO(2) with the SenTec monitor every two minutes until minute 20 and arterial blood gas (ABG) analysis. Overshoot severity: (a) mild (0.1-1.9 mm Hg); (b) moderate (2-4.9 mm Hg); (c) severe: (>5 mm Hg). The mean difference was calculated for SpO(2) and TcPCO(2) and arterial values of PaCO(2) and SpO(2). The intraclass correlation coefficient (ICC) between monitor readings and blood values was calculated as a measure of agreement. The mean age was 63.1 ± 11.8 years. Spirometric values: FVC: 75.4 ± 6.2%; FEV(1): 72.9 ± 23.9%; FEV(1)/FVC: 70 ± 15.5%. ABG: PaO(2): 82.6 ± 13.2; PaCO(2): 39.9.1 ± 4.8 mmHg; SaO(2): 95.3 ± 4.4%. Overshoot analysis: overshoot was mild in 33 (36.3%) patients, moderate in 20 (22%) and severe in nine (10%); no overshoot was observed in 29 (31%) patients. The lowest mean differences between arterial blood gas and TcPCO(2) was -0.57 mmHg at minute 10, although the highest ICC was obtained at minutes 12 and 14 (>0.8). The overshoot lost its influence after minute 12. For SpO(2), measurements were reliable at minute 2. The optimal clinical reading measurement recommended for the ear lobe TcPCO(2) measurement ranges between minute 12 and 14. The SpO(2) measurement can be performed at minute 2.

  19. Optimal Clinical Time for Reliable Measurement of Transcutaneous CO2 with Ear Probes: Counterbalancing Overshoot and the Vasodilatation Effect

    Directory of Open Access Journals (Sweden)

    Manel Luján

    2010-01-01

    Full Text Available OBJECTIVES: To determine the optimal clinical reading time for the transcutaneous measurement of oxygen saturation (SpO and transcutaneous CO2 (TcPCO2 in awake spontaneously breathing individuals, considering the overshoot phenomenon (transient overestimation of arterial PaCO2. EXPERIMENTAL SECTION: Observational study of 91 (75 men individuals undergoing forced spirometry, measurement of SpO2 and TcPCO2 with the SenTec monitor every two minutes until minute 20 and arterial blood gas (ABG analysis. Overshoot severity: (a mild (0.1–1.9 mm Hg; (b moderate (2–4.9 mm Hg; (c severe: (>5 mm Hg. The mean difference was calculated for SpO2 and TcPCO2 and arterial values of PaCO2 and SpO2. The intraclass correlation coefficient (ICC between monitor readings and blood values was calculated as a measure of agreement. RESULTS: The mean age was 63.1 ± 11.8 years. Spirometric values: FVC: 75.4 ± 6.2%; FEV1: 72.9 ± 23.9%; FEV1/FVC: 70 ± 15.5%. ABG: PaO2: 82.6 ± 13.2; PaCO2: 39.9.1 ± 4.8 mmHg; SaO2: 95.3 ± 4.4%. Overshoot analysis: overshoot was mild in 33 (36.3% patients, moderate in 20 (22% and severe in nine (10%; no overshoot was observed in 29 (31% patients. The lowest mean differences between arterial blood gas and TcPCO2 was –0.57 mmHg at minute 10, although the highest ICC was obtained at minutes 12 and 14 (>0.8. The overshoot lost its influence after minute 12. For SpO2, measurements were reliable at minute 2. CONCLUSIONS: The optimal clinical reading measurement recommended for the ear lobe TcPCO2 measurement ranges between minute 12 and 14. The SpO2 measurement can be performed at minute 2.

  20. Optimal Clinical Time for Reliable Measurement of Transcutaneous CO2 with Ear Probes: Counterbalancing Overshoot and the Vasodilatation Effect

    Science.gov (United States)

    Domingo, Christian; Canturri, Elisa; Moreno, Amalia; Espuelas, Humildad; Vigil, Laura; Luján, Manel

    2010-01-01

    OBJECTIVES: To determine the optimal clinical reading time for the transcutaneous measurement of oxygen saturation (SpO2) and transcutaneous CO2 (TcPCO2) in awake spontaneously breathing individuals, considering the overshoot phenomenon (transient overestimation of arterial PaCO2). EXPERIMENTAL SECTION: Observational study of 91 (75 men) individuals undergoing forced spirometry, measurement of SpO2 and TcPCO2 with the SenTec monitor every two minutes until minute 20 and arterial blood gas (ABG) analysis. Overshoot severity: (a) mild (0.1–1.9 mm Hg); (b) moderate (2–4.9 mm Hg); (c) severe: (>5 mm Hg). The mean difference was calculated for SpO2 and TcPCO2 and arterial values of PaCO2 and SpO2. The intraclass correlation coefficient (ICC) between monitor readings and blood values was calculated as a measure of agreement. RESULTS: The mean age was 63.1 ± 11.8 years. Spirometric values: FVC: 75.4 ± 6.2%; FEV1: 72.9 ± 23.9%; FEV1/FVC: 70 ± 15.5%. ABG: PaO2: 82.6 ± 13.2; PaCO2: 39.9.1 ± 4.8 mmHg; SaO2: 95.3 ± 4.4%. Overshoot analysis: overshoot was mild in 33 (36.3%) patients, moderate in 20 (22%) and severe in nine (10%); no overshoot was observed in 29 (31%) patients. The lowest mean differences between arterial blood gas and TcPCO2 was −0.57 mmHg at minute 10, although the highest ICC was obtained at minutes 12 and 14 (>0.8). The overshoot lost its influence after minute 12. For SpO2, measurements were reliable at minute 2. CONCLUSIONS: The optimal clinical reading measurement recommended for the ear lobe TcPCO2 measurement ranges between minute 12 and 14. The SpO2 measurement can be performed at minute 2. PMID:22315552

  1. Spirometric and hygienic criteria in recognition of occupational COPD in Poland - A retrospective analysis of medical records.

    Science.gov (United States)

    Kleniewska, Aneta; Walusiak-Skorupa, Jolanta; Lipińska-Ojrzanowska, Agnieszka; Szcześniak, Kamila; Wiszniewska, Marta

    2018-01-07

    Chronic obstructive pulmonary disease (COPD) may be work-related. It has been estimated that 15% of the population burden of COPD is attributable to occupational exposure. However, in Poland COPD is rarely recognized as an occupational disease. The aim of the study has been to analyze the causes of the low prevalence of work-related COPD in the context of the existing criteria as well as to analyze which part of the assessment - clinical or hygienic one - is responsible for such a low rate of occupational COPD recognitions. The study group included 150 patients hospitalized with a suspicion of occupational COPD. Each patient underwent a clinical examination, spirometry and reversibility test using bronchodilator. Moreover, hygienic evaluation of work conditions was performed in all the considered cases. In the case of the patients who fulfilled the criteria for COPD diagnosis in accordance with the Global Initiative for Chronic Obstructive Lung Disease (GOLD) occupational origins of the disease, the disease was not recognized because 24.1% of the individuals did not meet spirometric criteria included in a definition of COPD in the Polish list of occupational diseases, while 27.8% of the individuals did not fulfill the criterion of a documented exposure to dusts and irritant gases. None of these criteria was fulfilled by 42.6% of the patients. In our country, both clinical and hygienic criteria result in limitations in recognition of occupational COPD. There is the need to establish new guidelines for the recognition of COPD as a compensable disease in Poland. Int J Occup Med Environ Health 2018;31(2):139-150. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  2. Radiotherapy of lung cancer: the inspiration breath hold with a spirometric monitoring

    International Nuclear Information System (INIS)

    Garcia, R.; Oozeer, R.; Le Thanh, H.; Chastel, D.; Doyen, J.C.; Chauvet, B.; Reboul, F.

    2002-01-01

    A CT acquisition during a free breathing examination generates images of poor quality. It creates an uncertainty on the reconstructed gross tumour volume and dose distribution. The aim of this study is to test the feasibility of a breath hold method applied in all preparation and treatment days. Five patients received a thoracic radiotherapy with the benefit of this procedure. The breathing of the patient was measured with a spirometer. The patient was coached to reproduce a constant level of breath-hold in a deep inspiration. Video glasses helped the patients to fix the breath-hold at the reference level. The patients followed the coaching during preparation and treatment, without any difficulty. The better quality of the CT reconstructed images resulted in an easier contouring. No movements of the gross tumour volume lead to a better coverage. The deep breath hold decreased the volume of irradiated lung. This method improves the reproducibility of the thoracic irradiation. The decrease of irradiated lung volume offers prospects in dose escalation and intensity modulation radiotherapy. (authors)

  3. Spirometric abnormalities associated with chronic bronchitis, asthma, and airway hyperresponsiveness among boilermaker construction workers

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, R.; Eisen, E,A,; Pothier, L,; Lewis, D,; Bledsoe, T,; Christiani, D.C. [Harvard University, Boston, MA (United States). School of Public Health

    2002-06-01

    In a 2-year longitudinal study of boilermaker construction workers, authors found a significant association between working at oil-fired, coal-fired, and gas-fired industries during the past year and reduced lung function. In the present study, authors investigated whether chronic bronchitis, asthma, or baseline methacholine airway responsiveness can explain the heterogeneity in lung function response to boilermaker work. Exposure was assessed with a work history questionnaire. Spirometry was performed annually to assess lung function. A generalized estimating equation approach was used to account for the repeated-measures design. One hundred eighteen boilermakers participated in the study. Self-reported history of chronic bronchitis and asthma were associated with a larger FEV1 reduction in response to workplace exposure at coal-fired and gas-fired industries. Although a high prevalence (39%) of airway hyperresponsiveness (provocative concentration of methacholine causing a 20% fall in FEVI of {lt} 8 mg/mL) among boilermakers was found, there was no consistent pattern of effect modification by airway responsiveness. Conclusions: Although chronic bronchitis and asthma were associated with a greater loss in lung function in response to hours worked as a boilermaker, and therefore they acted as effect modifiers of the exposure-lung function relationship, airway hyperresponsiveness did not. However, the high prevalence of airway hyperresponsiveness found in the cohort may be a primary consequence of long-term workplace exposure among boilermakers.

  4. Oscillometric and spirometric bronchodilator response in preschool children with and without asthma

    Science.gov (United States)

    Shin, Youn Ho; Jang, Sun Jung; Yoon, Jung Won; Jee, Hye Mi; Choi, Sun Hee; Yum, Hye Yung; Warburton, David; Han, Man Yong

    2012-01-01

    BACKGROUND: Bronchodilator responses (BDR) are routinely used in the diagnosis and management of asthma; however, their acceptability and repeatability have not been evaluated using quality control criteria for preschool children. OBJECTIVES: To compare conventional spirometry with an impulse oscillometry system (IOS) in healthy and asthmatic preschool children. METHODS: Data from 30 asthmatic children and 29 controls (two to six years of age) who underwent IOS and spirometry before and after salbutamol administration were analyzed. RESULTS: Stable asthmatic subjects significantly differed versus controls in their spirometry-assessed BDR (forced expiratory volume in 1 s [FEV1], forced vital capacity and forced expiratory flow at 25% to 75% of forced vital capacity) as well as their IOS-assessed BDR (respiratory resistance at 5 Hz [Rrs5], respiratory reactance at 5 Hz and area under the reactance curve). However, comparisons based on the area under the ROC curve for ΔFEV1 % initial versus ΔRrs5 % initial were 0.82 (95% CI 0.71 to 0.93) and 0.75 (95% CI 0.62 to 0.87), respectively. Moreover, the sensitivity and specificity for ΔFEV1 ≥9% were 0.53 and 0.93, respectively. Importantly, sensitivity increased to 0.63 when either ΔFEV1 ≥9% or ΔRrs5 ≥29% was considered as an additional criterion for the diagnosis of asthma. CONCLUSION: The accuracy of asthma diagnosis in preschool children may be increased by combining spirometry with IOS when measuring BDR. PMID:22891189

  5. The Concave Shape of the Forced Expiratory Flow-Volume Curve in 3 Seconds Is a Practical Surrogate of FEV1/FVC for the Diagnosis of Airway Limitation in Inadequate Spirometry.

    Science.gov (United States)

    Li, Hao; Liu, Chunhong; Zhang, Yi; Xiao, Wei

    2017-03-01

    Spirometry is important for the differential diagnosis of dyspnea. However, some patients cannot exhale for ≥6 s to achieve the American Thoracic Society/European Respiratory Society criteria. The aim of this study was to demonstrate the reliability of a new parameter that quantifies the degree of concavity in the first 3 s to define airway limitation as a surrogate for the FEV 1 /FVC. Four hundred spirometry test results were selected through complete random sampling. The new parameter, termed the AUC 3 /AT 3 , was calculated as the area under the descending limb of the expiratory flow-volume curve before the end of the first 3 s (AUC 3 ) divided by the area of the triangle before the end of the first 3 s (AT 3 ). The AUC 3 /AT 3 was compared with the FEV 1 /FVC using Pearson's correlation analysis. The level of agreement between the AUC 3 /AT 3 and the FEV 1 /FVC in the detection of airway obstruction was analyzed using the kappa statistic. We also compared the diagnostic accuracy of the new index with that of the FEV 1 /forced expiratory volume in the first 3 s (FEV 3 ). There was a strong correlation (r = 0.88, P < .001) between the AUC 3 /AT 3 and the FEV 1 /FVC. There was also strong agreement between the AUC 3 /AT 3 and the FEV 1 /FVC in the detection of obstruction with kappa indices of 0.72 (Global Initiative for Chronic Obstructive Lung Disease [GOLD] criterion) and 0.67 (lower limit of normal criterion), and these values were greater than those obtained for the FEV 1 /FEV 3 . The AUC 3 /AT 3 also exhibited acceptable sensitivity, specificity, positive predictive value, and negative predictive value. The diagnostic accuracies of the AUC 3 /AT 3 were 86.3% (GOLD criterion) and 83.8% (lower limit of normal criterion), which were greater than the 76.0 and 74.0% obtained for the FEV 1 /FEV 3 , respectively. The AUC 3 /AT 3 can be utilized as a surrogate parameter for the FEV 1 /FVC when patients cannot complete a 6-s expiratory effort. Additionally, the

  6. Comparison of the fixed ratio and the Z-score of FEV1/FVC in the elderly population: a long-term mortality analysis from the Third National Health and Nutritional Examination Survey.

    Science.gov (United States)

    Oh, Dong Kyu; Baek, Seunghee; Lee, Sei Won; Lee, Jae Seung; Lee, Sang-Do; Oh, Yeon-Mok

    2018-01-01

    Despite the ongoing intense debate on the definition of airflow limitation by spirometry in the elderly population, there have only been few studies comparing the fixed ratio and the Z -score of forced expiratory volume in 1 second (FEV 1 )/forced vital capacity (FVC) in terms of long-term mortalities. In this study, we aimed to identify the proper method for accurately defining the airflow limitation in terms of long-term mortality prediction in the elderly population. Data were collected from the Third National Health and Nutrition Examination Survey in the US. Non-Hispanic Caucasians aged 65-80 years were included. The receiver operating characteristic (ROC) curves of both methods were plotted and compared for 10-year all-cause, respiratory, and COPD mortalities. Of 1,331 subjects, the mean age was 71.7 years and 805 (60.5%) were males. For the 10-year all-cause mortality, the area under the curve (AUC) of the fixed ratio was significantly greater than that of the Z -score of FEV 1 /FVC, but both showed poor prediction performance (0.633 vs 0.616, p ratio and the Z -score of FEV 1 /FVC showed comparable prediction performance with greater AUCs (0.784 vs 0.778, p =0.160, and 0.896 vs 0.896, p =0.971, respectively). Interestingly, the conventional cutoff of 0.7 in the fixed ratio was consistently higher than the optimal for the 10-year all-cause, respiratory, and COPD mortalities (0.70 vs 0.69, 0.62, and 0.61, respectively), whereas that of -1.64 in the Z -score of FEV 1 /FVC was consistently lower than the optimal cutoff (-1.64 vs -1.31, -1.47, and -1.41, respectively). In the elderly population, both the fixed ratio and the Z -score of FEV 1 /FVC showed comparable prediction performance for the 10-year respiratory and COPD mortalities. However, the conventional cutoff of neither 0.70 in the fixed ratio nor -1.64 in the Z -score of FEV 1 /FVC was optimal for predicting the long-term mortalities.

  7. Study of respiratory function in the elderly with different nutritional and cognitive status and functional ability assessed by plethysmographic and spirometric parameters.

    Science.gov (United States)

    De Filippi, Francesco; Tana, Francesco; Vanzati, Simona; Balzarini, Barbara; Galetti, Giuseppe

    2003-01-01

    From a sample of 265 elderly subjects (age 80.2 +/- 6.8 years) admitted to a geriatric care unit, free from cardiac and respiratory diseases, with normal chest X-ray and gas analysis, 53 subjects were selected and their respiratory functions (assessed by spirometric parameters and airway resistance 'Raw') were studied to correlate them with nutritional status, cognitive impairment, independence in everyday life activities and mood disorders, assessed, respectively, by the Mini Nutritional Assessment, rapid Mini Mental State test (MMSr), activities of daily living (ADL), instrumental activities of daily living (IADL) evaluation, Barthel Index and Cornell Depression Scale. The enrolled subjects were able to perform normally a forced expiration, although most of them committed errors in this test, according to the American Thoracic Society (ATS) criteria. Thus, about 32% started at lung volume0.12 s); in 62% of the subjects expiration time was too short and in 58% the terminal plateau was nutritional status did not seem to have any influence on spirometric performance; MMSr score was related to compliance with ATS criteria for acceptability of the forced manoeuvre; mental and mood disorders, nutritional conditions and disability did not seem to have any influence on error rates. Our data show that our geriatric enrolled patients were able to perform an imperfect, often unfinished, but acceptable forced expiration; dynamic index values were related to disability, while the errors in starting the test were related to the mental conditions.

  8. Body posture and pulmonary function in mouth and nose breathing children: cross-sectional study

    Directory of Open Access Journals (Sweden)

    Jovana de Moura Milanesi

    Full Text Available Abstract Introduction: Mouth breathing can lead to changes in body posture and pulmonary function. However, the consequences are still inconclusive and a number of studies are controversial. Objective: Evaluate and correlate spirometric parameters and postural measures in mouth breathing children, and compare them to nose breathers. Methods: two groups of 6 to 12 year-old children were evaluated: mouth breathers (MB, n = 55 and nose breathers (NB, n = 45. Spirometry and body posture analysis using photogrammetry (SAPo 0.68® v were carried out. The following spirometric measures were evaluated: peak expiratory flow (PEF, forced expiratory volume in 1 second (FEV1, forced vital capacity (FVC, FEV1/FVC ratio (% and forced expiratory flow between 25% and 75% of FVC (FEF 25-75%. Biophotogrammetric measures analyzed were: horizontal alignment of acromions (HAA and anterior superior iliac spine (HAASIS, Charpy angle, horizontal alignment of the head (HAH, cervical lordosis (CL, thoracic kyphosis (TK, lumbar lordosis (LL, cervical distance (CD and lumbar distance (LD. Results: There were no intergroup differences in spirometric and postural variables. Positive and moderate correlations were found between CL and CD measures with PEF, FEV1, FVC and FEF 25-75%, while weak correlations were observed between lumbar lordosis and PEF, FEV1 and FVC. Conclusion: The breathing mode had no influence on postural and respiratory measures. However, greater forward head posture, with smaller cervical lordosis, was related to higher lung volumes and flows in both groups.

  9. Canadian prediction equations of spirometric lung function for Caucasian adults 20 to 90 years of age: Results from the Canadian Obstructive Lung Disease (COLD) study and the Lung Health Canadian Environment (LHCE) study

    DEFF Research Database (Denmark)

    Tan, Wan C; Bourbeau, J; Hernandez, P

    2011-01-01

    BACKGROUND: Currently, no reference or normative values for spirometry based on a randomly selected Canadian population exist. OBJECTIVE: The aim of the present analysis was to construct spirometric reference values for Canadian adults 20 to 90 years of age by combining data collected from health...

  10. Spiroergometric and Spirometric Parameters in Patients with Multiple Sclerosis: Are there any Links between these Parameters and Fatigue, Depression, Neurological Impairment, Disability, Handicap and Quality of Life in Multiple Sclerosis?

    Czech Academy of Sciences Publication Activity Database

    Řasová, K.; Brandejský, P.; Havrdová, E.; Zálišová, M.; Rexová, Patrícia

    2005-01-01

    Roč. 11, - (2005), s. 213-221 ISSN 1352-4585 Grant - others:GA UK(CZ) 1641/2002-IV-GA UK Institutional research plan: CEZ:AV0Z10300504 Keywords : fatigue * multiple sclerosis * spirometric and spiroergometric parameters Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 2.832, year: 2005

  11. Comparison of the fixed ratio and the Z-score of FEV1/FVC in the elderly population: a long-term mortality analysis from the Third National Health and Nutritional Examination Survey

    Directory of Open Access Journals (Sweden)

    Oh DK

    2018-03-01

    Full Text Available Dong Kyu Oh,1 Seunghee Baek,2 Sei Won Lee,1 Jae Seung Lee,1 Sang-Do Lee,1 Yeon-Mok Oh1 1Department of Pulmonary and Critical Care Medicine, Clinical Research Center for Chronic Obstructive Airway Diseases, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea; 2Department of Clinical Epidemiology and Biostatistics, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea Background and objective: Despite the ongoing intense debate on the definition of airflow limitation by spirometry in the elderly population, there have only been few studies comparing the fixed ratio and the Z-score of forced expiratory volume in 1 second (FEV1/forced vital capacity (FVC in terms of long-term mortalities. In this study, we aimed to identify the proper method for accurately defining the airflow limitation in terms of long-term mortality prediction in the elderly population. Methods: Data were collected from the Third National Health and Nutrition Examination Survey in the US. Non-Hispanic Caucasians aged 65–80 years were included. The receiver operating characteristic (ROC curves of both methods were plotted and compared for 10-year all-cause, respiratory, and COPD mortalities. Results: Of 1,331 subjects, the mean age was 71.7 years and 805 (60.5% were males. For the 10-year all-cause mortality, the area under the curve (AUC of the fixed ratio was significantly greater than that of the Z-score of FEV1/FVC, but both showed poor prediction performance (0.633 vs 0.616, p<0.001. For the 10-year respiratory and COPD mortalities, both the fixed ratio and the Z-score of FEV1/FVC showed comparable prediction performance with greater AUCs (0.784 vs 0.778, p=0.160, and 0.896 vs 0.896, p=0.971, respectively. Interestingly, the conventional cutoff of 0.7 in the fixed ratio was consistently higher than the optimal for the 10-year all-cause, respiratory, and COPD mortalities (0.70 vs 0.69, 0.62, and 0.61, respectively

  12. Gender differences in first and secondhand smoke exposure, spirometric lung function and cardiometabolic health in the old order Amish: A novel population without female smoking.

    Science.gov (United States)

    Reed, Robert M; Dransfield, Mark T; Eberlein, Michael; Miller, Michael; Netzer, Giora; Pavlovich, Mary; Pollin, Toni I; Scharf, Steven M; Shuldiner, Alan R; Sin, Don; Mitchell, Braxton D

    2017-01-01

    Due to their relatively homogeneous lifestyle and living environment, the Amish offer a novel opportunity to study the health associations of tobacco smoke exposure, particularly secondhand smoke. We hypothesized that secondhand smoke exposure is associated with worse pulmonary and cardiometabolic health. We examined cross-sectional data on 3568 Amish study participants, including tobacco use and secondhand smoke exposure from family members included in the study. Thirty-four percent of Amish men reported ever smoking. Of this proportion, 64% used cigars, 46% cigarettes, and 21% pipes. Less than 1% of women reported ever smoking. Smoking was associated with lower spirometric lung function, higher body mass index, lower HDL cholesterol, higher heart rate, lower ankle-brachial index, and larger aortic diameter in men. A greater number of sources of secondhand smoke exposure (defined from the total of spouses, parents, and siblings who smoke) was associated with higher body mass index (p = 0.03) and with higher fasting glucose in men (p = 0.01), but not in women (p = 0.007 for sex*secondhand smoke interaction). Secondhand smoke exposure was also associated with reduced HDL cholesterol only in women (p = 0.002) and a lower heart rate only in men (p = 0.006). Smoking habits among the Old Order Amish are notable for the absence of female participation and a high proportion of cigar and pipe use. Smoking is associated with decreased spirometric indices of lung function and increased cardiovascular risk in this population and secondhand smoke exposure is associated with a greater burden of risk factors for cardiovascular disease. Sex differences in correlations could reflect differences in exposure patterns, mechanisms, or susceptibilities.

  13. Flow-volume loops measured with electrical impedance tomography in pediatric patients with asthma.

    Science.gov (United States)

    Ngo, Chuong; Dippel, Falk; Tenbrock, Klaus; Leonhardt, Steffen; Lehmann, Sylvia

    2018-05-01

    Electrical impedance tomography (EIT) provides information on global and regional ventilation during tidal breathing and mechanical ventilation. During forced expiration maneuvers, the linearity of EIT and spirometric data has been documented in healthy persons. The present study investigates the potential diagnostic use of EIT in pediatric patients with asthma. EIT and spirometry were performed in 58 children with asthma (average age ± SD: 11.86 ± 3.13 years), and 58 healthy controls (average age ± SD: 12.12 ± 2.9 years). The correlation between EIT data and simultaneously acquired spirometric data were tested for FEV 1 , FEV 0.5 , MEF 75 , MEF 50 , and MEF 25 . Binary classification tests were performed for the EIT-derived Tiffeneau index FEV 1 /FVC and the bronchodilator test index ΔFEV 1 . Average flow-volume (FV) loops were generated for patients with pathologic spirometry to demonstrate the feasibility of EIT for graphic diagnosis of asthma. Spirometry and global EIT-based FV loops showed a strong correlation (P  0.9 in FEV 1 and FEV 0.5 ). In all criteria, the binary classification tests yielded high specificity (>93%), a high positive predictive value (≥75%) and a high negative predictive value (>80%), while sensitivity was higher in ΔFEV 1 (86.67%) and lower in FEV 1 /FVC (25% and 35.29%). A typical concave shape of the EIT-derived average FV loops was observed for asthmatic children with improvement after bronchospasmolysis. Global FV loops derived from EIT correlate well with spirometry. Positive bronchospasmolysis can be observed in EIT-derived FV loops. Flow-volume loops originated from EIT have a potential to visualize pulmonary function. © 2018 Wiley Periodicals, Inc.

  14. SHORT COMMUNICATION: Reduction of Spirometric Lung Function Tests in Habitually Smoking Healthy Young Adults: It’s Correlation with Pack Years

    Directory of Open Access Journals (Sweden)

    Sumangala M Patil

    2012-01-01

    Full Text Available Background: Adolescent smoking and the subsequent health problems are a major concern today. However there are very few studies done on spirometric lung functions and its relation with pack years in young adult habitual smokers who are apparently healthy. Aims and Objectives: The present study is undertaken to assess the change in lung functions in apparently healthy young adult habitual smokers compared to their age matched controls. Materials and Methods: A random sample of apparently healthy young adult habitual smokers (n=40 and nonsmokers (n=40 between age group17-35 years with history suggesting of pack years of 2-10 years were selected from students & employee’s of B.L.D.E.U’s Sri B.M. Patil Medical College,Hospital & Research Centre Bijapur (Karnataka, India. Spirometric lung functions recorded were forced expiratory volume in one second (FEV1, FEV1%, Peak expiratory flow rate (PEFR and Maximal expiratory pressure (MEP. Results: The results suggested that inapparently healthy habitual smokers there was significant decrease in FEV1 (L (-13.34%, p<0.001, FEV1 % (-10.76%, p<0.001, PEFR (-45.26%, p<0.0001 and MEP (-35.51%, p<0.0001 compared to nonsmokers and decrease in FEV1 was negatively correlated withpack years in smokers (r2=0.063, p=0.001. Reduced lung functions and negative correlation to pack years may be attributed todecreased airway diameter & reflex broncho- constriction in response to inhaled smoke particles. Conclusions: In conclusion young adulthabitual smokers who were apparently healthy are more prone for respiratory dysfunction than their nonsmoker counterparts. FEV1 reduction in relation to pack years acts as an important determinant for detecting lung dysfunction in the early stage of the disease. As the risk of having smoking related diseases depends mainly on number of pack years, it is suggested that quitting smoking earliest helps to get greatest health benefits in apparently healthy young adult habitual smokers.

  15. Genetic Influences on Pulmonary Function: A Large Sample Twin Study

    DEFF Research Database (Denmark)

    Ingebrigtsen, Truls S; Thomsen, Simon F; van der Sluis, Sophie

    2011-01-01

    Heritability of forced expiratory volume in one second (FEV(1)), forced vital capacity (FVC), and peak expiratory flow (PEF) has not been previously addressed in large twin studies. We evaluated the genetic contribution to individual differences observed in FEV(1), FVC, and PEF using data from...... the largest population-based twin study on spirometry. Specially trained lay interviewers with previous experience in spirometric measurements tested 4,314 Danish twins (individuals), 46-68 years of age, in their homes using a hand-held spirometer, and their flow-volume curves were evaluated. Modern variance...

  16. Validity of physician-diagnosed COPD in relation to spirometric definitions of COPD in a general population aged 50–64 years – the SCAPIS pilot study

    Directory of Open Access Journals (Sweden)

    Torén K

    2017-08-01

    Full Text Available Kjell Torén,1,2 Nicola Murgia,1,2 Anna-Carin Olin,1 Jan Hedner,3 John Brandberg,4 Annika Rosengren,5 Göran Bergström51Section of Occupational and Environmental Medicine, Sahlgrenska Academy, University of Gothenburg, Sweden; 2Section of Occupational Medicine, Respiratory Diseases and Toxicology, University of Perugia, Italy; 3Department of Medicine/Lung Medicine, Sahlgrenska Academy, University of Gothenburg, 4Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, 5Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Sweden Background: In epidemiological studies, items about physician-diagnosed COPD are often used. There is a lack of validation and standardization of these items.Materials and methods: In a general population-based study, 1,050 subjects completed a questionnaire and performed spirometry, including forced expiratory volume in 1 second (FEV1 and forced vital capacity (FVC after inhalation of 400 µg of salbutamol. COPD was defined as the ratio of FEV1/FVC <0.7 after bronchodilation. Physician-diagnosed COPD was defined as an affirmative answer to the single item: “Have you ever had COPD diagnosed by a physician?”, physician-diagnosed COPD/emphysema as an affirmative answer to any of the two single items; “Have you ever had COPD diagnosed by a physician?” or “Have you ever been told by a physician that you have emphysema?”, physician-diagnosed chronic bronchitis as an affirmative answer to; “Have you ever been told by a physician that you have chronic bronchitis?” and physician-diagnosed COPD, emphysema or chronic bronchitis was defined as an affirmative answer to either of the three items above.Results: For the single item about physician-diagnosed COPD, the sensitivity was around 0.11 and the specificity was almost 0.99 in relation to COPD. The sensitivity of the combined items about COPD

  17. O efeito da obesidade sobre parâmetros espirométricos em adolescentes submetidos à broncoprovocação por exercício = The effect of obesity on spirometric parameters in adolescents subjected to exercise bronchoprovocation

    Directory of Open Access Journals (Sweden)

    Fabrício Cieslak

    2010-01-01

    Full Text Available O objetivo deste estudo foi avaliar o efeito da obesidade sobre parâmetros espirométricos em adolescentes submetidos ao teste de broncoprovocação por exercício físico. Estudo transversal, descritivo e correlacional, composto por 15 adolescentes, de ambos os sexos. O diagnóstico de asma foi realizado por meio de histórico clínico e questionário ISAAC, e a obesidade, pelo IMC acima do percentil 95. Utilizou-se o teste de broncoprovocação com exercício físico para avaliação da asma induzida pelo exercício (AIE, considerando-se positiva a diminuição do volume expiratório forçado no primeiro segundo (VEF1 > 10% do valor pré-exercício e a intensidade da AIE foi calculada pela queda percentual máxima do VEF1 (% Quedamáx VEF1. Foram utilizados o teste t independente ou U de Mann-Whitney e a correlação de Spearman rho (p The objective of this study was to evaluate the effect of obesity on spirometric parameters in adolescents subjected to a physical exercise bronchoprovocation test. It was a cross-sectional, descriptive and correlational study composed of 15 adolescents of both genders. The diagnosis of asthma was made by clinical history and ISAAC questionnaire, and obesity by BMI above the 95th percentile. The bronchoprovocation test with physical exercise was used for assessment of exercise induced asthma (EIA, considering positive a decrease in forced expiratory volume in one second (FEV1 > 10% of pre-exercise, and the intensity was calculated by the EIA maximum percentage fall in FEV1 (% Fallmax FEV1. We used the independent t test or Mann-Whitney U test and the Spearman rho correlation (p < 0.05. Significant differences were found between asthmatics and non-asthmatics to % Fallmax FEV1 (p = 0.034. There was a negative moderate relationship to Fallmax FEV1 with leukocytes, and % Fallmax FEV1 with leukocytes. It can be concluded that the spirometric variables presented moderated correlation with the systemic inflammation of

  18. Chronic tuberculous empyema: relationships between preoperative CT findings and postoperative improvement measured by pulmonary function testing

    International Nuclear Information System (INIS)

    Kim, D.J.; Im, J.-G.; Goo, J.M.; Lee, H.J.; You, S.Y.; Song, J.W.

    2005-01-01

    AIMS: To evaluate whether preoperative computed tomography (CT) findings correlate with postoperative improvements in forced vital capacity (FVC) and forced expiratory volume during 1 s (FEV1) in persons who have undergone unilateral decortication because of unilateral chronic tuberculous empyema. METHODS: A retrospective study was carried out of 67 individuals who had undergone decortication because of chronic tuberculous empyema between January 1996 and December 2000. Of these, 13 subjects who had had preoperative chest CT and preoperative and postoperative pulmonary function tests (PFTs) were included in the investigation. On preoperative CT, the degree of volume reduction of the affected side was compared with that of the contralateral normal lung. The relative volume of empyema was calculated by dividing the volume occupied by the empyema by the sum of the total volume of the ipsilateral lung and the empyema volume. The thicknesses of pleura and extrapleural fat in the involved hemithorax were measured by CT at their thickest points, and the degree of atelectasis adjacent to the empyema in the diseased lung was assessed and classified. These five CT parameters and the ages of the patients were compared with preoperative and postoperative FVC and FEV1 changes. RESULTS: A significant negative correlation was found between FVC changes and the relative volume of the affected lung (FVC: p=0.039, RS=-0.58). FVC and FEV1 were found to be significantly and positively correlated with the relative volume of the empyema (FVC: p=0.005, RS=0.72; FEV1: p=0.014, RS=0.66) and the degree of atelectasis (FVC: p=0.007, RS=0.71; FEV1: p=0.029, RS=0.60) by Spearman's nonparametric correlation test. Other CT parameters and the ages of the patients were not found to be correlated with PFT changes. CONCLUSION: The relative volume of the affected side, the relative volume of empyema and the degree of atelectasis can predict improvements in FVC and FEV1 after decortication in patients

  19. Effects of equipment and technique on peak flow measurements

    Directory of Open Access Journals (Sweden)

    O'Driscoll B Ronan

    2006-06-01

    Full Text Available Abstract Background Different lung function equipment and different respiratory manoeuvres may produce different Peak Expiratory Flow (PEF results. Although the PEF is the most common lung function test, there have been few studies of these effects and no previous study has evaluated both factors in a single group of patients. Methods We studied 36 subjects (PEF range 80–570 l/min. All patients recorded PEF measurements using a short rapid expiration following maximal inspiration (PEF technique or a forced maximal expiration to residual volume (FVC technique. Measurements were made using a Wright's peak flow meter, a turbine spirometer and a Fleisch pneumotachograph spirometer. Results The mean PEF was 8.7% higher when the PEF technique was used (compared with FVC technique, p Conclusion Peak flow measurements are affected by the instruction given and by the device and Peak Flow scale used. Patient management decisions should not be based on PEF measurement made on different instruments.

  20. Association between Traffic Air Pollution and Reduced Forced Vital Capacity: A Study Using Personal Monitors for Outdoor Workers.

    Directory of Open Access Journals (Sweden)

    Ubiratan Paula Santos

    Full Text Available The effects of outdoor air pollution on lung function in adults are still controversial.Evaluate the effects of exposure to different levels of traffic-generated PM2.5 on workers' lung functions in São Paulo, Brazil.To cover a wide range of exposures, 101 non-smoking workers from three occupations (taxi drivers, traffic controllers, and forest rangers were selected for the study. After clinical evaluation, the participants were scheduled to attend four consecutive weekly visits in which they received a 24-hour personal PM2.5 sampler and had lung function tests measured on the following day. The association between the spirometric variables and the averaged PM2.5 levels was assessed using robust regression models adjusted for age, waist circumference, time at the job, daily work hours, diabetes or hypertension and former smoking habits.Relative to workers in the lowest exposed group (all measures 39.6 μg/m3 showed a reduction of predicted FVC (-12.2%; CI 95%: [-20.0% to -4.4%], a marginal reduction of predicted FEV1 (-9.1%; CI 95%: [-19.1% to 0.9%] and an increase of predicted FEF25-75%/FVC (14.9%; CI 95%: [2.9% to 26.8%] without changes of FEV1/FVC.Exposure to vehicular traffic air pollution is associated with a small but significant reduction of FVC without a reduction of FEV1/FVC.

  1. Effectiveness of regular reporting of spirometric results combined with a smoking cessation advice by a primary care physician on smoking quit rate in adult smokers: a randomized controlled trial. ESPIROTAB study

    Directory of Open Access Journals (Sweden)

    Martínez-González Silvia

    2011-06-01

    Full Text Available Abstract Background Undiagnosed airflow limitation is common in the general population and is associated with impaired health and functional status. Smoking is the most important risk factor for this condition. Although primary care practitioners see most adult smokers, few currently have spirometers or regularly order spirometry tests in these patients. Brief medical advice has shown to be effective in modifying smoking habits in a large number of smokers but only a small proportion remain abstinent after one year. The aim of this study is to evaluate the effectiveness of regular reporting of spirometric results combined with a smoking cessation advice by a primary care physician on smoking quit rate in adult smokers. Methods/design Intervention study with a randomized two arms in 5 primary care centres. A total of 485 smokers over the age of 18 years consulting their primary care physician will be recruited. On the selection visit all participants will undergo a spirometry, peak expiratory flow rate, test of smoking dependence, test of motivation for giving up smoking and a questionnaire on socio-demographic data. Thereafter an appointment will be made to give the participants brief structured advice to give up smoking combined with a detailed discussion on the results of the spirometry. After this, the patients will be randomised and given appointment for follow up visits at 3, 6, 12 and 24 months. Both arms will receive brief structured advice and a detailed discussion of the spirometry results at visit 0. The control group will only be given brief structured advice about giving up smoking on the follow up. Cessation of smoking will be tested with the carbon monoxide test. Discussion Early identification of functional pulmonary abnormalities in asymptomatic patients or in those with little respiratory symptomatology may provide "ideal educational opportunities". These opportunities may increase the success of efforts to give up smoking and

  2. Urinary Dialkyl Phosphate Concentrations and Lung Function Parameters in Adolescents and Adults: Results from the Canadian Health Measures Survey.

    Science.gov (United States)

    Ye, Ming; Beach, Jeremy; Martin, Jonathan W; Senthilselvan, Ambikaipakan

    2016-04-01

    Epidemiological studies have reported associations between lung function parameters and organophosphate (OP) pesticide exposures in agricultural occupations, but to our knowledge associations have not been evaluated in general populations. We examined associations between OP metabolite dialkyl phosphates (DAPs) and lung function using data from the Canadian Health Measures Survey (CHMS) Cycle 1. Forced vital capacity (FVC), forced expiratory volume in 1 sec (FEV1), FEV1/FVC ratio, and forced expiratory flow between 25% and 75% of FVC (FEF25%-75%) were measured for 4,446 CHMS participants. Urinary concentrations of six DAP metabolites (DMP, DMTP, DMDTP, DEP, DETP, and DEDTP), smoking status, and other predictors of lung function were also measured in the CHMS-Cycle 1. Multiple linear regression analyses were used to examine the relationship between total DAP concentrations (ΣDAPs) and lung function in adolescents (12-19 years) and adults (20-79 years). In adults, estimates from multiple regression analyses suggested that a 1-unit increase on natural logarithmic scale (171% increase on the original scale) in the creatinine-corrected urinary concentration (nanomoles per gram creatinine) of ΣDAP was associated with a 32.6-mL (95% CI: -57.2, -8.1) reduction in FVC, 32.6-mL (95% CI: -59.0, -6.3) reduction in FEV1, 0.2% (95% CI: -0.6, 0.2) reduction in FEV1/FVC ratio, and 53.1-mL/sec (95% CI: -113.9, 7.7) reduction in FEF25%-75%. In adolescents, associations between ΣDAP and FEV1 were closer to the null and positive for FVC, whereas associations with FEV1/FVC and FEF25%-75% were negative, as in adults. However, none of the associations were significant in adolescents. The negative association between ΣDAP and lung function in adult participants suggests a detrimental effect of OP pesticides on lung function in the adult general population. Further studies using prospective designs are warranted to confirm the findings reported in this study. Ye M, Beach J, Martin JW

  3. Clearance of technetium-99m-labeled DTPA in hyperthyroidism without clinical evidence of lung disease, and relation to pulmonary function

    International Nuclear Information System (INIS)

    Guldiken, S.; Tugrul, A.; Altiay, G.; Hacimahmutoglu, S.; Durmus-Altun, G.

    2005-01-01

    The mechanisms of dyspnea and exercise intolerance have not been fully elucidated. We aimed to investigate the clearance rate of technetium-99m diethyltriaminepentaaceticacid (Tc-99m DTPA) from lungs in hyperthyroid patients without clinical evidence of lung disease and to explore the interactions between their Tc-99m DTPA radioaerosol lung scintigraphy, spirometric measurements, and the levels of thyroid hormones. We studied 19 hyperthyroid patients and 16 sex- and age-matched controls. Thyroid hormone levels were assessed. Spirometric lung function tests, diffusing capacity of the lung for carbon monoxide (DLCO) and the clearance rate of Tc-99m DTPA were performed in all participants. Ratio of DLCO value to the alveolar ventilation (DLCO/VA) and the means of half-time (T 1/2 ) of Tc-99m DTPA clearance rate, which were used to evaluate alveolar-capillary membrane permeability, were calculated. There were no statistical differences between spirometric parameters (vital capacity (VC), force vital capacity (FVC), one second forced expiratory volume (FEV 1 )/FVC, mean forced expiratory flow during the middle of FVC (FEF 25-75)) of the two groups (p>0.05). Although the mean FEV 1 level was significantly lower in the hyperthyroid patients than the control subjects (p 1 was only less than 80 percent of the predicted value. No significant difference in the means of DLCO, DLCO/VA or T 1/2 values of Tc-99m DTPA clearance was observed between the two groups (p>0.05). In hyperthyroid patients, there was a positive relation between DLCO/VA, DLCO/VA% and T 1/2 values of Tc-99m DTPA clearance (p 1/2 values of Tc-99m DTPA clearance in hyperthyroid group (p>0.05). We conclude that increased thyroid hormones have no effect on permeability of alveolar-capillary membrane in hyperthyroid patients. (author)

  4. Measurement of tidal volume using respiratory ultrasonic plethysmography in anaesthetized, mechanically ventilated horses.

    Science.gov (United States)

    Russold, Elena; Ambrisko, Tamas D; Schramel, Johannes P; Auer, Ulrike; Van Den Hoven, Rene; Moens, Yves P

    2013-01-01

    To compare tidal volume estimations obtained from Respiratory Ultrasonic Plethysmography (RUP) with simultaneous spirometric measurements in anaesthetized, mechanically ventilated horses. Prospective randomized experimental study. Five experimental horses. Five horses were anaesthetized twice (1 week apart) in random order in lateral and in dorsal recumbency. Nine ventilation modes (treatments) were scheduled in random order (each lasting 4 minutes) applying combinations of different tidal volumes (8, 10, 12 mL kg(-1)) and positive end-expiratory pressures (PEEP) (0, 10, 20 cm H(2)O). Baseline ventilation mode (tidal volume=15 mL kg(-1), PEEP=0 cm H(2)O) was applied for 4 minutes between all treatments. Spirometry and RUP data were downloaded to personal computers. Linear regression analyses (RUP versus spirometric tidal volume) were performed using different subsets of data. Additonally RUP was calibrated against spirometry using a regression equation for all RUP signal values (thoracic, abdominal and combined) with all data collectively and also by an individually determined best regression equation (highest R(2)) for each experiment (horse versus recumbency) separately. Agreement between methods was assessed with Bland-Altman analyses. The highest correlation of RUP and spirometric tidal volume (R(2)=0.81) was found with the combined RUP signal in horses in lateral recumbency and ventilated without PEEP. The bias ±2 SD was 0±2.66 L when RUP was calibrated for collective data, but decreased to 0±0.87 L when RUP was calibrated with individual data. A possible use of RUP for tidal volume measurement during IPPV needs individual calibration to obtain limits of agreement within ±20%. © 2012 The Authors. Veterinary Anaesthesia and Analgesia. © 2012 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.

  5. Measurement

    NARCIS (Netherlands)

    Boumans, M.; Durlauf, S.N.; Blume, L.E.

    2008-01-01

    Measurement theory takes measurement as the assignment of numbers to properties of an empirical system so that a homomorphism between the system and a numerical system is established. To avoid operationalism, two approaches can be distinguished. In the axiomatic approach it is asserted that if the

  6. Comparação da variação de resposta ao broncodilatador através da espirometria em portadores de asma ou doença pulmonar obstrutiva crônica Comparison of spirometric changes in the response to bronchodilators of patients with asthma or chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Isabella Correia Silvestri

    2008-09-01

    Full Text Available OBJETIVO: O diagnóstico diferencial entre asma e doença pulmonar obstrutiva crônica (DPOC através da resposta aos broncodilatadores inalatórios na espirometria ainda é controverso. O objetivo deste estudo foi detectar quais variáveis espirométricas melhor diferenciam asma de DPOC. MÉTODOS: Estudo retrospectivo realizado entre abril de 2004 e janeiro de 2006, comparando-se os parâmetros espirométricos de 103 pacientes asmáticos, não fumantes, com os de 108 pacientes portadores de DPOC, fumantes de mais de 10 anos-maço. Todos os pacientes tinham mais de 40 anos e apresentavam doença estável no momento do exame. RESULTADOS: O volume expiratório forçado no primeiro segundo (VEF1 pré-broncodilatador foi igual nos dois grupos (VEF1 = 51%, mas os portadores de DPOC eram mais velhos (66 ± 9 anos vs. 59 ± 11 anos, p 10% constitui o melhor parâmetro espirométrico para diferenciar asma de DPOC.OBJECTIVE: Making the differential diagnosis between asthma and chronic obstructive pulmonary disease (COPD based on the response to inhaled bronchodilators by means of spirometry is controversial. The objective of this study was to identify the most useful spirometric variables in order to distinguish between asthma and COPD. METHODS: Retrospective study conducted from April of 2004 to January of 2006, comparing the spirometric parameters of 103 nonsmoking patients with asthma to those of 108 patients with COPD who were smokers for more than 10 pack-years. All of the patients included in the study were older than 40 and presented stable disease at the time of the test. RESULTS:Initial forced expiratory volume in one second (FEV1 was the same in the two groups (pre-bronchodilator VEF1 = 51%. However, patients with COPD were older (66 ± 9 years vs. 59 ± 11 years, p 10% is the best spirometric parameter to distinguish asthma from COPD.

  7. Validation of Global Lung Function Initiative and All Ages Reference Equations for Forced Spirometry in Healthy Spanish Preschoolers.

    Science.gov (United States)

    Martín de Vicente, Carlos; de Mir Messa, Inés; Rovira Amigo, Sandra; Torrent Vernetta, Alba; Gartner, Silvia; Iglesias Serrano, Ignacio; Carrascosa Lezcano, Antonio; Moreno Galdó, Antonio

    2018-01-01

    Recent publication of multi-ethnic spirometry reference equations for subjects aged from 3-95 years aim to avoid age-related discontinuities and provide a worldwide standard for interpreting spirometric test results. To assess the agreement of the Global Lung Function Initiative (GLI-2012) and All ages (FEV 0.5 ) reference equations with the Spanish preschool lung function data. To verify the appropriateness of these reference values for clinical use in Spanish preschool children. Spirometric measurements were obtained from children aged 3 to 6 years attending 10 randomly selected schools in Barcelona (Spain). Stanojevic's quality control criteria were applied. Z-scores were calculated for the spirometry outcomes based on the GLI equations. If the z-score (mean) of each parameter was close to 0, with a maximum variance of ± 0.5 from the mean and a standard deviation of 1, the GLI-2012 equations would be applicable in our population. Of 543 children recruited, 405 (74.6%) were 'healthy', and of these, 380 were Caucasians. Of these 380, 81.6% (169 females, 141 males) performed technically acceptable and reproducible maneuvers to assess FEVt, and 69.5% achieved a clear end-expiratory plateau. Z-scores for FVC, FEV 1 , FEV 1 /FVC, FEV 0.75 , FEV 0.75 /FVC, FEV 0.5 , FEF 75 and FEF 25-75 all fell within ± 0.5, except for FEV 1 /FVC (0.53 z-scores). GLI equations are appropriate for Spanish preschool children. These data provide further evidence to support widespread application of the GLI reference equations. Copyright © 2017 SEPAR. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Measuring $\

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Jessica Sarah [Univ. of Cambridge (United Kingdom)

    2011-01-01

    The MINOS Experiment consists of two steel-scintillator calorimeters, sampling the long baseline NuMI muon neutrino beam. It was designed to make a precise measurement of the ‘atmospheric’ neutrino mixing parameters, Δm2 atm. and sin2 (2 atm.). The Near Detector measures the initial spectrum of the neutrino beam 1km from the production target, and the Far Detector, at a distance of 735 km, measures the impact of oscillations in the neutrino energy spectrum. Work performed to validate the quality of the data collected by the Near Detector is presented as part of this thesis. This thesis primarily details the results of a vμ disappearance analysis, and presents a new sophisticated fitting software framework, which employs a maximum likelihood method to extract the best fit oscillation parameters. The software is entirely decoupled from the extrapolation procedure between the detectors, and is capable of fitting multiple event samples (defined by the selections applied) in parallel, and any combination of energy dependent and independent sources of systematic error. Two techniques to improve the sensitivity of the oscillation measurement were also developed. The inclusion of information on the energy resolution of the neutrino events results in a significant improvement in the allowed region for the oscillation parameters. The degree to which sin2 (2θ )= 1.0 could be disfavoured with the exposure of the current dataset if the true mixing angle was non-maximal, was also investigated, with an improved neutrino energy reconstruction for very low energy events. The best fit oscillation parameters, obtained by the fitting software and incorporating resolution information were: | Δm2| = 2.32+0.12 -0.08×10-3 eV2 and sin2 (2θ ) > 0.90(90% C.L.). The analysis provides the current world best measurement of the atmospheric neutrino mass

  9. The association between anthropometric measures and lung function in a population-based study of Canadian adults.

    Science.gov (United States)

    Rowe, A; Hernandez, P; Kuhle, S; Kirkland, S

    2017-10-01

    Decreased lung function has health impacts beyond diagnosable lung disease. It is therefore important to understand the factors that may influence even small changes in lung function including obesity, physical fitness and physical activity. The aim of this study was to determine the anthropometric measure most useful in examining the association with lung function and to determine how physical activity and physical fitness influence this association. The current study used cross-sectional data on 4662 adults aged 40-79 years from the Canadian Health Measures Survey Cycles 1 and 2. Linear regression models were used to examine the association between the anthropometric and lung function measures (forced expiratory volume in 1 s [FEV 1 ] and forced vital capacity [FVC]); R 2 values were compared among models. Physical fitness and physical activity terms were added to the models and potential confounding was assessed. Models using sum of 5 skinfolds and waist circumference consistently had the highest R 2 values for FEV 1 and FVC, while models using body mass index consistently had among the lowest R 2 values for FEV 1 and FVC and for men and women. Physical activity and physical fitness were confounders of the relationships between waist circumference and the lung function measures. Waist circumference remained a significant predictor of FVC but not FEV 1 after adjustment for physical activity or physical fitness. Waist circumference is an important predictor of lung function. Physical activity and physical fitness should be considered as potential confounders of the relationship between anthropometric measures and lung function. Copyright © 2017. Published by Elsevier Ltd.

  10. Efecto del pedaleo de brazos sobre el sistema cardiorrespiratorio de las personas con tetraplejia. (Effect of armcrank pedaling on the cardiorespiratory system of the people with tetraplegia.

    Directory of Open Access Journals (Sweden)

    Gabriel Brizuela Costa

    2010-10-01

    Full Text Available Resumen Objetivos: Determinar el efecto de un programa de entrenamiento de pedaleo de brazos (PB estacionario, sobre el sistema cardiorrespiratorio de personas con tetraplejia. Método: Se estudiaron 11 participantes con tetraplejia por lesión medular (LM de origen traumático a niveles entre C4 y C6. Se midieron variables espirométricas (VC, FVC y MVV y de Variabilidad de la Frecuencia Cardíaca VFC (HR, STDHR, RMSSD, LF, HF y HRVPOWER, antes y después de 8 semanas de entrenamiento. Resultados: Todas las variables mostraron cambios significativos (p Abstract Objective: The aim of the study was to determine the effect, in subjects with tetraplejia, of a stationary armcrank pedaling (AP training program on their cardiorespiratory system. Method: 11 participants with tetraplegia, originated by traumatic spinal cord injury (SCI at levels between C4 and C6, were included in the study. Spirometric (VC, FVC and MVV and Heart Rate Variability (HRV indices (HR, STDHR, RMSSD, LF, HF, HRVPOWER were measured before and after an 8 weeks of armcrank pedaling training program. Results: Spirometric and HRV variables showed changes (p

  11. Virtual respiratory system for interactive e-learning of spirometry

    Directory of Open Access Journals (Sweden)

    W. Tomalak

    2008-04-01

    Full Text Available Progress in computer simulation technology offers new possibilities for modern medicine. On one hand – virtual organs can help to create animal or human models for research, on the other hand – e-learning or distant learning through Internet is now possible. The aim of our work was to create a system for interactive learning of spirometry (SILS, enabling students or physicians to observe spirometric measurements (flow-volume modified by setting level and kind of abnormalities within the respiratory system. SILS is based on a virtual respiratory system presented previously in several papers. Its main features are: separation of the lungs and chest; anatomical division of the lungs; division of airway resistance into transmural pressure dependent (Rp and lung volume dependent (Rv parts. The one mathematical formula that represents Rp describes both flow limitation (forced expiration and dependence of Raw on lungs volume (small airflows. The output of system are spirometric parameters (as FEV1, FVC, FEV1%FVC and a flow–volume loop constructed according to results of simulation of forced expiration for the chosen abnormality kind and level. As a result – this system may be used in teaching process in medical schools and postgraduate education. We offer access to a basic version of SILS for students and physicians at: www.spirometry.ibib.waw.pl and www.zpigichp.edu.pl. As we expect feedback from users, it is possible to modify user interface or model features to comply with users' requests.

  12. Lower lung function associates with cessation of menstruation: UK Biobank data.

    Science.gov (United States)

    Amaral, André F S; Strachan, David P; Gómez Real, Francisco; Burney, Peter G J; Jarvis, Deborah L

    2016-11-01

    Little is known about the effect of cessation of menstruation on lung function. The aims of the study were to examine the association of lung function with natural and surgical cessation of menstruation, and assess whether lower lung function is associated with earlier age at cessation of menstruation.The study was performed in 141 076 women from the UK Biobank, who had provided acceptable and reproducible spirometry measurements and information on menstrual status. The associations of lung function (forced vital capacity (FVC), forced expiratory volume in 1 s (FEV 1 ), spirometric restriction (FVC menstruation and age at cessation of menstruation were assessed using regression analysis.Women who had natural cessation of menstruation showed a lower FVC (-42 mL; 95% CI -53- -30) and FEV 1 (-34 mL; 95% CI -43- -24) and higher risk of spirometric restriction (adjusted odds ratio 1.27; 95% CI 1.18-1.37) than women still menstruating. These associations were stronger in women who had had a hysterectomy and/or oophorectomy. The earlier the natural cessation of menstruation, the lower the lung function. There was no clear association of lung function with age at hysterectomy and/or oophorectomy. Airflow obstruction was not associated with cessation of menstruation.Lower lung function associates with cessation of menstruation, especially if it occurs early in life. Copyright ©ERS 2016.

  13. Computed tomography measurement of rib cage morphometry in emphysema.

    Directory of Open Access Journals (Sweden)

    Nicola Sverzellati

    Full Text Available BACKGROUND: Factors determining the shape of the human rib cage are not completely understood. We aimed to quantify the contribution of anthropometric and COPD-related changes to rib cage variability in adult cigarette smokers. METHODS: Rib cage diameters and areas (calculated from the inner surface of the rib cage in 816 smokers with or without COPD, were evaluated at three anatomical levels using computed tomography (CT. CTs were analyzed with software, which allows quantification of total emphysema (emphysema%. The relationship between rib cage measurements and anthropometric factors, lung function indices, and %emphysema were tested using linear regression models. RESULTS: A model that included gender, age, BMI, emphysema%, forced expiratory volume in one second (FEV1%, and forced vital capacity (FVC% fit best with the rib cage measurements (R(2 = 64% for the rib cage area variation at the lower anatomical level. Gender had the biggest impact on rib cage diameter and area (105.3 cm(2; 95% CI: 111.7 to 98.8 for male lower area. Emphysema% was responsible for an increase in size of upper and middle CT areas (up to 5.4 cm(2; 95% CI: 3.0 to 7.8 for an emphysema increase of 5%. Lower rib cage areas decreased as FVC% decreased (5.1 cm(2; 95% CI: 2.5 to 7.6 for 10 percentage points of FVC variation. CONCLUSIONS: This study demonstrates that simple CT measurements can predict rib cage morphometric variability and also highlight relationships between rib cage morphometry and emphysema.

  14. O efeito da obesidade sobre parâmetros espirométricos em adolescentes submetidos à broncoprovocação por exercício - DOI: 10.4025/actascihealthsci.v32i1.6476 The effect of obesity on spirometric parameters in adolescents subjected to exercise bronchoprovocation - DOI: 10.4025/actascihealthsci.v32i1.6476

    Directory of Open Access Journals (Sweden)

    Rosana Bento Radominski

    2009-12-01

    Full Text Available O objetivo deste estudo foi avaliar o efeito da obesidade sobre parâmetros espirométricos em adolescentes submetidos ao teste de broncoprovocação por exercício físico. Estudo transversal, descritivo e correlacional, composto por 15 adolescentes, de ambos os sexos. O diagnóstico de asma foi realizado por meio de histórico clínico e questionário ISAAC, e a obesidade, pelo IMC acima do percentil 95. Utilizou-se o teste de broncoprovocação com exercício físico para avaliação da asma induzida pelo exercício (AIE, considerando-se positiva a diminuição do volume expiratório forçado no primeiro segundo (VEF1 > 10% do valor pré-exercício e a intensidade da AIE foi calculada pela queda percentual máxima do VEF1 (% QuedaMax VEF1. Foram utilizados o teste t independente ou U de Mann-Whitney e a correlação de Spearman rho (p máx VEF1 (p = 0,034. Houve relação moderada negativa para a QuedaMax VEF1 com os leucócitos, e do % QuedaMax VEF1 com os leucócitos. Pode-se concluir que as variáveis espirométricas apresentam moderada correlação com as inflamações sistêmicas da obesidade. Palavras-chave: adolescente; asma induzida pelo exercício; obesidade.The objective of this study was to evaluate the effect of obesity on spirometric parameters in adolescents subjected to a physical exercise bronchoprovocation test. It was a cross-sectional, descriptive and correlational study composed of 15 adolescents of both genders. The diagnosis of asthma was made by clinical history and ISAAC questionnaire, and obesity by BMI above the 95th percentile. The bronchoprovocation test with physical exercise was used for assessment of exercise induced asthma (EIA, considering positive a decrease in forced expiratory volume in one second (FEV1 > 10% of pre-exercise, and the intensity was calculated by the EIA maximum percentage fall in FEV1 (% Fallmax FEV1. We used the independent t test or Mann-Whitney U test and the Spearman rho correlation (p 1

  15. Diagnosing asthma in general practice with portable exhaled nitric oxide measurement – results of a prospective diagnostic study

    Directory of Open Access Journals (Sweden)

    Laux Gunter

    2009-03-01

    Full Text Available Abstract Background To evaluate the sensitivity, specificity and predictive values of fractional exhaled nitric oxide (FENO for the diagnosis of asthma in general practice. Methods Prospective diagnostic study with 160 patients attending 10 general practices for the first time with complaints suspicious of obstructive airway disease (OAD. Patients were referred to a lung function laboratory for diagnostic investigation. The index test was FENO measured with a portable FENO analyser based on electrochemical sensor. The reference standard was the Tiffeneau ratio (FEV1/VC as received by spirometric manoeuvre and/or results of bronchial provocation. Bronchial provocation with methacholine was performed to determine bronchial hyper-responsiveness (BHR in the event of inconclusive spirometric results. Results 88 (55% were female; their average age was 43.9 years. 75 (46.9% patients had asthma, 25 (15.6% had COPD, 8 (5.0% had an overlap of COPD and asthma, and 52 (32.5% had no OAD. At a cut-off level of 46 parts per billion (ppb (n = 30; 18.8%, sensitivity was 32% (95%CI 23–43%, specificity 93% (95%CI 85–97%, positive predictive value (PPV 80% (95%CI 63–91%, negative predictive value (NPV 61% (95%CI 52–69% when compared with a 20% fall in FEV1 from the baseline value (PC20 after inhaling methacholine concentration ≤ 16 mg/ml. At 76 ppb (n = 11; 6.9% specificity was 100% (95%CI 96–100% and PPV was 100% (95%CI 72–100. At a cut-off level of 12 ppb (n = 34; 21.3%, sensitivity was 90% (95%CI 79–95%, specificity 25% (95%CI 17–34%, PPV 40% (95%CI 32–50, NPV 81% (95%CI 64–91% when compared with a 20% fall of FEV1 after inhaling methacholine concentration ≤ 4 mg/ml. Three patients with unsuspicious spirometric results have to be tested with FENO to save one bronchial provocation test. Conclusion Asthma could be ruled in with FENO > 46 ppb. Mild and moderate to severe asthma could be ruled out with FENO ≤ 12 ppb. FENO measurement with

  16. Influence of the diving wetsuit on standard spirometry

    NARCIS (Netherlands)

    Schellart, Nico A. M.; Sterk, Wouter

    2016-01-01

    INTRODUCTION A well-fitting wetsuit exerts a pressure on the body that may influence spirometry. This pressure is expected to reduce the forced vital capacity (FVC) due to hampered inspiration. Since the shape of the spirometric flow curve should not be changed by the pressure effects of the

  17. High body mass index and risk of exacerbations and pneumonias in individuals with chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Çolak, Yunus; Afzal, Shoaib; Lange, Peter

    2016-01-01

    descent, aged 20-100 years, from the Copenhagen General Population Study, for FTO (rs9939609), MC4R (rs17782313) and TMEM18 (rs6548238), and created an allele score. A total of 10 883 individuals had spirometric COPD with forced expiratory volume in 1 s (FEV1) / forced vital capacity (FVC)

  18. Comparison of forced expiratory spirometric flow changes following ...

    African Journals Online (AJOL)

    Group B received intrathecal anaesthesia 15 mgs of bupivacaine with 0.5 ml of normal saline and Group BF received 15 mgs of bupivacaine with 0.5 ml of fentanyl (25 μg) intrathecally. The patients were instructed about the performance of the spirometry on the previous evening of the surgery. Forced vital capacity, forced ...

  19. Predictive equations for spirometric reference values in a healthy ...

    African Journals Online (AJOL)

    men and 98 women were selected to the reference value group. ... adult population in Dar es Salaam, Tanzania, and compare these equations to already ... which has proven to be suitable in field work as it operates on batteries and requires no ..... thought to be partly due to difference in body build and that Blacks have ...

  20. Efficacy of lung ventilation scintigram and exercise pulmonary hemodynamic measurement to evaluate operability for pulmonary resection

    International Nuclear Information System (INIS)

    Kaneda, Masanori; Hayashi, Takashi; Hiraiwa, Takane; Sakai, Takashi; Namikawa, Shoji; Kusakawa, Minoru.

    1989-01-01

    Preoperative evaluation of patients with lung cancer should include data concerning both resectability and operability. Operability addresses the question how much pulmonary tissue can be safely removed. The purpose of this study is to demonstrate an efficacy of the lung ventilation scintigram and measurement of exercise change in pulmonary hemodynamic parameters by detecting respiratory and circulatory reserve of pulmonary function. Predicted postoperative forced vital capacity (FVC) were calculated from the data of lung scintigram and preoperative spirometry by means of subsegmental formula. Accuracy of prediction was confirmed by spirometry 6 months after the operation. Correlation coefficient between predicted value and actually measured one was R=0.95, and simple regression formula was y=0.98x-10.4. It was recommended that the lower limit should be setted at 40% by the calculated postoperative %FVC. Exercise test were performed by means of bicycle ergometer with the measurement of pulmonary arterial pressure and cardiac output. Pulmonary arterial resistance index (PARI) were also calculated. In younger group rise of pulmonary arterial pressure during exercise was gentle, and PARI was settled between 150 to 200 in high output state. But in older group rise of pulmonary aerial pressure was steep and PARI was over 200 in some cases, just like the case of COLD. It should be recommended to set the upper limit of PARI at 400 in maximum exercise. (author)

  1. Measurement of lung volume by lung perfusion scanning using SPECT and prediction of postoperative respiratory function

    International Nuclear Information System (INIS)

    Andou, Akio; Shimizu, Nobuyosi; Maruyama, Shuichiro

    1992-01-01

    Measurement of lung volume by lung perfusion scanning using single photon emission computed tomography (SPECT) and its usefulness for the prediction of respiratory function after lung resection were investigated. The lung volumes calculated in 5 patients by SPECT (threshold level 20%) using 99m Tc-macroaggregated albumin (MAA), related very closely to the actually measured lung volumes. This results prompted us to calculate the total lung volume and the volume of the lobe to be resected in 18 patients with lung cancer by SPECT. Based on the data obtained, postoperative respiratory function was predicted. The predicted values of forced vital capacity (FVC), forced expiratory volume (FEV 1.0 ), and maximum vital volume (MVV) showed closer correlations with the actually measured postoperative values (FVC, FEV 1.0 , MVV : r=0.944, r=0.917, r=0.795 respectively), than the values predicted by the ordinary lung perfusion scanning. This method facilitates more detailed evaluation of local lung function on a lobe-by-lobe basis, and can be applied clinically to predict postoperative respiratory function. (author)

  2. Linearity of electrical impedance tomography during maximum effort breathing and forced expiration maneuvers.

    Science.gov (United States)

    Ngo, Chuong; Leonhardt, Steffen; Zhang, Tony; Lüken, Markus; Misgeld, Berno; Vollmer, Thomas; Tenbrock, Klaus; Lehmann, Sylvia

    2017-01-01

    Electrical impedance tomography (EIT) provides global and regional information about ventilation by means of relative changes in electrical impedance measured with electrodes placed around the thorax. In combination with lung function tests, e.g. spirometry and body plethysmography, regional information about lung ventilation can be achieved. Impedance changes strictly correlate with lung volume during tidal breathing and mechanical ventilation. Initial studies presumed a correlation also during forced expiration maneuvers. To quantify the validity of this correlation in extreme lung volume changes during forced breathing, a measurement system was set up and applied on seven lung-healthy volunteers. Simultaneous measurements of changes in lung volume using EIT imaging and pneumotachography were obtained with different breathing patterns. Data was divided into a synchronizing phase (spontaneous breathing) and a test phase (maximum effort breathing and forced maneuvers). The EIT impedance changes correlate strictly with spirometric data during slow breathing with increasing and maximum effort ([Formula: see text]) and during forced expiration maneuvers ([Formula: see text]). Strong correlations in spirometric volume parameters [Formula: see text] ([Formula: see text]), [Formula: see text]/FVC ([Formula: see text]), and flow parameters PEF, [Formula: see text], [Formula: see text], [Formula: see text] ([Formula: see text]) were observed. According to the linearity during forced expiration maneuvers, EIT can be used during pulmonary function testing in combination with spirometry for visualisation of regional lung ventilation.

  3. Increase in prevalence and severity of asthma in young adults in Copenhagen

    DEFF Research Database (Denmark)

    Hansen, Ejvind Frausing; Rappeport, Y; Vestbo, Jørgen

    2000-01-01

    BACKGROUND: It is the general impression that the prevalence of asthma has increased during recent decades. A study was undertaken to investigate asthma prevalence, respiratory symptoms, and lung function in young adults in the City of Copenhagen 15 years apart. METHODS: Men and women aged 20......-35 years were sampled from the general population living in a defined area of central Copenhagen. The first examination took place in 1976-8 and comprised 1034 subjects (response rate 67.2%). A new sample comprising 1104 subjects (response rate 62.6%) from exactly the same area was examined 15 years later...... in 1991-4. All participants answered a questionnaire on respiratory symptoms and diseases and performed spirometric tests with measurement of forced expiratory volume in one second (FEV(1)) and forced vital capacity (FVC). RESULTS: The prevalence of self-reported asthma increased from 1.5% in the first...

  4. Evaluation of three scales of dyspnea in chronic obstructive pulmonary disease

    International Nuclear Information System (INIS)

    Chhabra, S K; Gupta, A K; Khuma, M Z

    2009-01-01

    The Modified Medical Research Council (MMRC) scale, baseline dyspnea index (BDI) and the oxygen cost diagram (OCD) are widely used tools for evaluation of limitation of activities due to dyspnea in patients with chronic obstructive pulmonary disease (COPD). There is, however, limited information on how these relate with each other and with multiple parameters of physiological impairment. To study the interrelationships between MMRC, BDI and OCD scales of dyspnea and their correlation with multiple measures of physiological impairment. A retrospective analysis of pooled data of 88 male patients with COPD (GOLD stages 2, 3 and 4) was carried out. Dyspnea was evaluated using the MMRC, BDI and OCD scales. Physiological impairment was assessed by spirometry (FVC % predicted and FEV 1 % predicted), arterial blood gas (ABG) analysis and measurement of the 6-min walk distance (6MWD). The interrelationships between MMRC, BDI and OCD scales were moderately strong. The BDI and OCD scores had strong correlations with ABG abnormalities, weak correlations with spirometric parameters but none with 6MWD. MMRC grades were significantly associated with BDI and OCD scores but did not show clear associations with spirometric parameters, ABG abnormalities and 6MWD. The MMRC grades of dyspnea and the BDI and OCD scales are moderately interrelated. While the BDI and OCD scales have significant associations with parameters of physiological impairment, the MMRC scale does not. (author)

  5. In vitro validation of a Pitot-based flow meter for the measurement of respiratory volume and flow in large animal anaesthesia.

    Science.gov (United States)

    Moens, Yves P S; Gootjes, Peter; Ionita, Jean-Claude; Heinonen, Erkki; Schatzmann, Urs

    2009-05-01

    To remodel and validate commercially available monitors and their Pitot tube-based flow sensors for use in large animals, using in vitro techniques. Prospective, in vitro experiment. Both the original and the remodelled sensor were studied with a reference flow generator. Measurements were taken of the static flow-pressure relationship and linearity of the flow signal. Sensor airway resistance was calculated. Following recalibration of the host monitor, volumes ranging from 1 to 7 L were generated by a calibration syringe, and bias and precision of spirometric volume was determined. Where manual recalibration was not available, a conversion factor for volume measurement was determined. The influence of gas composition mixture and peak flow on the conversion factor was studied. Both the original and the remodelled sensor showed similar static flow-pressure relationships and linearity of the flow signal. Mean bias (%) of displayed values compared with the reference volume of 3, 5 and 7 L varied between -0.4% and +2.4%, and this was significantly smaller than that for 1 L (4.8% to +5.0%). Conversion factors for 3, 5 and 7 L were very similar (mean 6.00 +/- 0.2, range 5.91-6.06) and were not significantly influenced by the gas mixture used. Increasing peak flow caused a small decrease in the conversion factor. Volume measurement error and conversion factors for inspiration and expiration were close to identity. The combination of the host monitor with the remodelled flow sensor allowed accurate in vitro measurement of flows and volumes in a range expected during large animal anaesthesia. This combination has potential as a reliable spirometric monitor for use during large animal anaesthesia.

  6. Cyst-based measurements for assessing lymphangioleiomyomatosis in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lo, P., E-mail: pechinlo@mednet.edu.ucla; Brown, M. S.; Kim, H.; Kim, H.; Goldin, J. G. [Center for Computer Vision and Imaging Biomarkers, Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California 90024 (United States); Argula, R.; Strange, C. [Division of Pulmonary and Critical Care Medicine, Medical University of South Carolina, Charleston, South Carolina 29425 (United States)

    2015-05-15

    Purpose: To investigate the efficacy of a new family of measurements made on individual pulmonary cysts extracted from computed tomography (CT) for assessing the severity of lymphangioleiomyomatosis (LAM). Methods: CT images were analyzed using thresholding to identify a cystic region of interest from chest CT of LAM patients. Individual cysts were then extracted from the cystic region by the watershed algorithm, which separates individual cysts based on subtle edges within the cystic regions. A family of measurements were then computed, which quantify the amount, distribution, and boundary appearance of the cysts. Sequential floating feature selection was used to select a small subset of features for quantification of the severity of LAM. Adjusted R{sup 2} from multiple linear regression and R{sup 2} from linear regression against measurements from spirometry were used to compare the performance of our proposed measurements with currently used density based CT measurements in the literature, namely, the relative area measure and the D measure. Results: Volumetric CT data, performed at total lung capacity and residual volume, from a total of 49 subjects enrolled in the MILES trial were used in our study. Our proposed measures had adjusted R{sup 2} ranging from 0.42 to 0.59 when regressing against the spirometry measures, with p < 0.05. For previously used density based CT measurements in the literature, the best R{sup 2} was 0.46 (for only one instance), with the majority being lower than 0.3 or p > 0.05. Conclusions: The proposed family of CT-based cyst measurements have better correlation with spirometric measures than previously used density based CT measurements. They show potential as a sensitive tool for quantitatively assessing the severity of LAM.

  7. Association between lung function in adults and plasma DDT and DDE levels: results from the Canadian Health Measures Survey.

    Science.gov (United States)

    Ye, Ming; Beach, Jeremy; Martin, Jonathan W; Senthilselvan, Ambikaipakan

    2015-05-01

    Although DDT [1,1,1-trichloro-2,2-bis(4-chlorophenyl)ethane] has been banned in many countries since the 1970s, it may still pose a risk to human respiratory health. In agriculture, DDT exposures have been associated with asthma and chronic bronchitis. However, little is known about the effect of DDT on lung function. We used data on 1,696 participants 20-79 years of age from the Canadian Health Measures Survey (CHMS) and conducted multiple regression analysis to estimate associations between plasma p,p´-DDT/DDE and lung function. Almost all participants (> 99.0%) had detectable concentrations of plasma p,p´-DDE, but only 10.0% had detectable p,p´-DDT. Participants with detectable p,p´-DDT had significantly lower mean FVC (difference = 311 mL; 95% CI: -492, -130; p = 0.003) and FEV1 (difference = 232 mL; 95% CI: -408, -55; p = 0.015) than those without. A 100-ng/g lipid increase in plasma p,p´-DDE was associated with an 18.8-mL decrease in mean FVC (95% CI: -29, -9) and an 11.8-mL decrease in mean FEV1 (95% CI: -21, -3). Neither exposure was associated with FEV1/FVC ratio or FEF25%-75%. DDT exposures, which may have occurred decades ago, were still detectable among Canadians. Plasma DDT and DDE were negatively associated with lung function parameters. Additional research on the potential effects of DDT use on lung function is warranted.

  8. Effect of Recumbent Body Positions on Dynamic Lung Function Parameters in Healthy Young Subjects.

    Science.gov (United States)

    Pal, Arvind Kumar; Tiwari, Sunita; Verma, Dileep Kumar

    2017-05-01

    The change in body position can alter pulmonary functions parameters, therefore it is important to understand the physiological basis of these alteration. Ideally, spirometry is done in sitting position until the subject is unable to do so. Hospitalized patients often assume recumbent body positions irrespective of underlying pathology. Hence, need arises to find out best recumbent body positions for the benefit of these patients to make breathing comfortable for them. The aim of this study was to find out whether the change from the supine position to crook lying and Fowler's position (45° dorsal elevation) causes change in spirometric parameters. The present work was carried out at Department of Physiology, King George's Medical University, Lucknow. A total 131 apparently healthy individuals were enrolled in this cross-sectional study. Lung function was assessed using a PC-based spirometer according to American Thoracic Society guideline in the supine, crook lying and Fowler's position (45° dorsal elevation). The study consisted of 131 subjects (male 66%, female 34%), with mean age of 20.15±2.71 years and BMI 21.20±3.28 Kg/m 2 . Repeated measures ANOVA with post hoc Bonferroni test was used to compare the mean values between each body position. Compared with the other two positions, Fowler's position showed significantly (p<0.05) higher values for FVC, FEV 1 , PEF, FEF 25-75% . Recumbent body position influences spirometric parameters in young healthy subjects. We demonstrated that spirometric values are higher in the Fowler's position than in the supine or crook lying position. The results of this study will help in the selection of the best alternative position for the spirometry in bed ridden patients.

  9. BMI, waist circumference at 8 and 12 years of age and FVC and FEV

    NARCIS (Netherlands)

    M.B.M. Bekkers (Marga); A.H. Wijga (Alet); U. Gehring (Ulrike); G.H. Koppelman (Gerard); J.C. de Jongste (Johan); H.A. Smit (Henriëtte); B. Brunekreef (Bert)

    2015-01-01

    textabstractBackground: In adults, overweight is associated with reduced lung function, in children evidence on this association is conflicting. We examined the association of body mass index (BMI) and waist circumference (WC) at age 12, and of persistently (at ages 8 and 12 years) high BMI and

  10. BMI, waist circumference at 8 and 12 years of age and FVC and FEV

    NARCIS (Netherlands)

    Bekkers, Marga B.; Wijga, Alet H.; Gehring, Ulrike; Koppelman, Gerard H.; de Jongste, Johan C.; Smit, Henriette A.; Brunekreef, Bert

    2015-01-01

    Background: In adults, overweight is associated with reduced lung function, in children evidence on this association is conflicting. We examined the association of body mass index (BMI) and waist circumference (WC) at age 12, and of persistently (at ages 8 and 12 years) high BMI and large WC, with

  11. Chronic adaptations of lung function in breath-hold diving fishermen

    Directory of Open Access Journals (Sweden)

    Cristiane Diniz

    2014-04-01

    Full Text Available Objectives: The aim of this study was to verify and analyze the existence of chronic adaptations of lung function in freediving fishermen whose occupation is artisanal fishing. Material and Methods: This was a cross-sectional study involving 11 breath-hold diving fishermen and 10 non-breath-hold diving fishermen (control from the village of Bitupitá in the municipality of Barroquinha (Ceará - Brazil. Anthropometric measurements, chest and abdominal circumferences as well as spirometric and respiratory muscle strength tests were conducted according to the specifications of the American Thoracic Society/European Respiratory Society (ATS/ERS. In order to compare the measured values versus the predicted values, Student t test was used in the case of parametric test and Wilcoxon test in the case of nonparametric test. To compare the inter-group means Student t test was used for parametric test and Mann-Whitney test for the nonparametric one. The level of significance was set at α = 5%. Results: The forced vital capacity (FVC (4.9±0.6 l vs. 4.3±0.4 l and forced expiratory volume in 1 s (FEV1 (4.0±0.5 l vs. 3.6±0.3 l were, respectively, higher in the group of divers compared to the control group (p ≤ 0.05. Furthermore, in the group of free divers, the measured FVC, FEV1 and FEV1/FVC ratios were significantly greater than the predicted ones. No differences were found between the measured respiratory pressures. Conclusions: These results indicate that breath-hold diving seems to produce chronic adaptations of the respiratory system, resulting in elevated lung volumes with no airway obstruction.

  12. Effects of occupational exposures and smoking on lung function in tile factory workers.

    Science.gov (United States)

    Jaakkola, Maritta S; Sripaiboonkij, Penpatra; Jaakkola, Jouni J K

    2011-02-01

    The aims of this study were to investigate the relations of occupational exposures in tile industry to lung function and to evaluate potential interaction between smoking and tile dust exposure containing silica. A cross-sectional study of 232 workers (response rate 100%) in a tile factory and 76 office workers (response rate 73%) from four factories in Thailand was conducted in 2006-2007. Participants answered a questionnaire and performed spirometry. Factory workers had lower spirometric functions than office workers, especially those with high dust exposure. There was a dose-response relation between duration of dust exposure and FEV1 and FVC, the adjusted effect of ≥ 21 years of exposure on FEV1 being -240 ml (-100 to -380) and on FVC -300 ml (-140 to -460). The adverse effect of dust on lung function was larger in current smokers suggesting synergism between smoking and tile dust exposure. This study provides evidence that long-term exposure to dust in tile industry is related to lung function reduction. There was a suggestion of synergistic effect between dust exposure and smoking. Tile factories should consider measures to reduce dust exposure and arrange spirometry surveillance for workers with such exposure. Smoking cessation should be promoted to prevent harmful effects of occupational tile dust exposure.

  13. Direct assessment of lung function in COPD using CT densitometric measures

    International Nuclear Information System (INIS)

    Gu, Suicheng; Leader, Joseph; Gur, David; Pu, Jiantao; Zheng, Bin; Chen, Qihang; Sciurba, Frank; Kminski, Naftali

    2014-01-01

    To investigate whether lung function in patients with chronic obstructive pulmonary disease (COPD) can be directly predicted using CT densitometric measures and assess the underlying prediction errors as compared with the traditional spirometry-based measures. A total of 600 CT examinations were collected from a COPD study. In addition to the entire lung volume, the extent of emphysema depicted in each CT examination was quantified using density mask analysis (densitometry). The partial least square regression was used for constructing the prediction model, where a repeated random split-sample validation was employed. For each split, we randomly selected 400 CT exams for training (regression) purpose and the remaining 200 exams for assessing performance in prediction of lung function (e.g., FEV1 and FEV1/FVC) and disease severity. The absolute and percentage errors as well as their standard deviations were computed. The averaged percentage errors in prediction of FEV1, FEV1/FVC%, TLC, RV/TLC% and DLco% predicted were 33%, 17%, 9%, 18% and 23%, respectively. When classifying the exams in terms of disease severity grades using the CT measures, 37% of the subjects were correctly classified with no error and 83% of the exams were either correctly classified or classified into immediate neighboring categories. The linear weighted kappa and quadratic weighted kappa were 0.54 (moderate agreement) and 0.72 (substantial agreement), respectively. Despite the existence of certain prediction errors in quantitative assessment of lung function, the CT densitometric measures could be used to relatively reliably classify disease severity grade of COPD patients in terms of GOLD. (paper)

  14. Peripheral airway impairment measured by oscillometry predicts loss of asthma control in children.

    Science.gov (United States)

    Shi, Yixin; Aledia, Anna S; Galant, Stanley P; George, Steven C

    2013-03-01

    We previously showed that impulse oscillometry (IOS) indices of peripheral airway function are associated with asthma control in children. However, little data exist on whether dysfunction in the peripheral airways can predict loss of asthma control. We sought to determine the utility of peripheral airway impairment, as measured by IOS, in predicting loss of asthma control in children. Fifty-four children (age, 7-17 years) with controlled asthma were enrolled in the study. Spirometric and IOS indices of airway function were obtained at baseline and at a follow-up visit 8 to 12 weeks later. Physicians who were blinded to the IOS measurements assessed asthma control (National Asthma Education and Prevention Program guidelines) on both visits and prescribed no medication change between visits. Thirty-eight (70%) patients maintained asthma control between 2 visits (group C-C), and 16 patients had asthma that became uncontrolled on the follow-up visit (group C-UC). There was no difference in baseline spirometric results between the C-C and C-UC groups, except for FEV1/forced vital capacity ratio (86% vs 82%, respectively; P IOS results, including resistance of the respiratory system at 5 Hz (R5; 6.4 vs 4.3 cm H2O · L(-1) · s), frequency dependence of resistance (difference of R5 and resistance of the respiratory system at 20 Hz [R5-20]; 2.0 vs 0.7 cm H2O · L(-1) · s), and reactance area (13.1 vs 4.1 cm H2O · L(-1)), of group C-UC were significantly higher than those of group C-C (P operating characteristic analysis showed baseline R5-20 and reactance area effectively predicted asthma control status at the follow-up visit (area under the curve, 0.91 and 0.90). Children with controlled asthma who have increased peripheral airway IOS indices are at risk of losing asthma control. Copyright © 2012 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  15. Impact of active and passive smoking as risk factors for asthma and COPD in women presenting to primary care in Syria: first report by the WHO-GARD survey group.

    Science.gov (United States)

    Mohammad, Yousser; Shaaban, Rafea; Al-Zahab, Bassam Abou; Khaltaev, Nikolai; Bousquet, Jean; Dubaybo, Basim

    2013-01-01

    The burden of chronic respiratory disease (CRD) is alarming. International studies suggest that women with CRD are undersurveyed and underdiagnosed by physicians worldwide. It is unclear what the prevalence of CRD is in the general population of Syria, particularly among women, since there has never been a survey on CRD in this nation. The purpose of this study was to investigate the impact of different patterns of smoking on CRD in women. We extracted data on smoking patterns and outcome in women from the Global Alliance Against Chronic Respiratory Diseases survey. Using spirometric measurements before and after the use of inhaled bronchodilators, we tracked the frequency of CRD in females active and passive narghile or cigarette smokers presenting to primary care. We administered the questionnaire to 788 randomly selected females seen during 1 week in the fiscal year 2009-2010 in 22 primary care centers in six different regions of Syria. Inclusion criteria were age >6 years, presenting for any medical complaint. In this cross-sectional study, three groups of female subjects were evaluated: active smokers of cigarettes, active smokers of narghiles, and passive smokers of either cigarettes or narghiles. These three groups were compared to a control group of female subjects not exposed to active or passive smoking. Exposure to active cigarette smoke but not narghile smoke was associated with doctor-diagnosed chronic obstructive pulmonary disease (COPD). However, neither cigarette nor narghile active smoking was associated with increased incidence of spirometrically diagnosed COPD. Paradoxically, exposure to passive smoking of either cigarettes or narghiles resulted in association with airway obstruction, defined as forced expiratory volume in 1 second (FEV1)/forced vital capacity (FVC) < 70% according to the Global initiative for chronic Obstructive Lung Disease criteria; association with FEV1 < 80% predicted, evidencing moderate to severe GOLD spirometric grade

  16. Instrument development in the measurement of unsupported arm exercise endurance in normal adult subjects.

    Science.gov (United States)

    Breslin, E H; Adams, E; Lutz, A; Roy, C

    1993-06-01

    Many daily activities, from basic grooming to employment tasks, require adequate unsupported arm endurance (UAE). We developed an electromechanical device to measure UAE endurance. The purpose of this study was to standardize the instrument for two rates of arm motion, moderate and slow, in 18 normal adult subjects (FEVI = 3.7L +/- .78, FVC = 4.2L +/- .74, FEV1/FVC = 1.1 +/- .08). Exercise endurance limits, and the following metabolic, ventilatory, and sensation responses were determined at rest prior to exercise and at end-exercise limits for both rates of UAE:minute ventilation (Ve), tidal volume (VT), respiratory rate (RR), duty cycle (Ti/Ttot), oxygen uptake (VO2), carbon dioxide production (VCO2), inspiratory flow (VT/Ti), heart rate (HR), and visual analog scale measurements (VAS) of dyspnea (D), respiratory effort (RE), and arm fatigue (AF). Significance increases from baseline rest were shown at the endurance limits for both rates of UAE in: VO2, VCO2, Ve, VT, RR, VT/Ti, HR, VAS-D, VAS-RE, and VAS-AF. There were no changes in Ti/Ttot and SaO2 with UAE. Peak VO2, RR, Ve, VT/Ti, and VAS-D with moderate exercise were significantly greater than slow UAE; and there was a trend increase in peak HR for moderate as opposed to slow rate UAE. Despite these differences, the endurance time between the two rates of UAE were similar. These data provide standards against which UAE in COPD can be evaluated.

  17. [The diagnosis of COPD is recommendation dependent].

    Science.gov (United States)

    Ben Saad, Helmi; Ben Amor, Leila; Ben Mdella, Samia; Ghannouchi, Ines; Ben Essghair, Mejda; Bougmiza, Iheb; Garrouche, Abdelhamid; Rouatbi, Naceur; Rouatbi, Sonia

    2014-07-01

    Different spirometric criteria are recommended to diagnosis chronic obstructive pulmonary disease (COPD): -American Thoracic Society/European Respiratory Society (ATS/ERS), Global initiative for chronic Obstructive Lung Disease (GOLD): a post bronchodilator (PBD) ratio between the 1st second Forced Expiratory Volume and Forced Vital Capacity (FEV1/FVC) guidelines are used for defining the disease. This forms a barrier to early diagnosis, affects public health decisions and wrong planning strategies.

  18. What quantum measurements measure

    Science.gov (United States)

    Griffiths, Robert B.

    2017-09-01

    A solution to the second measurement problem, determining what prior microscopic properties can be inferred from measurement outcomes ("pointer positions"), is worked out for projective and generalized (POVM) measurements, using consistent histories. The result supports the idea that equipment properly designed and calibrated reveals the properties it was designed to measure. Applications include Einstein's hemisphere and Wheeler's delayed choice paradoxes, and a method for analyzing weak measurements without recourse to weak values. Quantum measurements are noncontextual in the original sense employed by Bell and Mermin: if [A ,B ]=[A ,C ]=0 ,[B ,C ]≠0 , the outcome of an A measurement does not depend on whether it is measured with B or with C . An application to Bohm's model of the Einstein-Podolsky-Rosen situation suggests that a faulty understanding of quantum measurements is at the root of this paradox.

  19. Quality of Life and Bronchial Hyper-Responsiveness in Subjects With Bronchiectasis: Validation of the Seattle Obstructive Lung Disease Questionnaire in Bronchiectasis.

    Science.gov (United States)

    Bulcun, Emel; Arslan, Mesut; Ekici, Aydanur; Ekici, Mehmet

    2015-11-01

    Bronchiectasis can adversely affect quality of life. However, the tests examining quality of life in bronchiectasis are not sufficient. We examined the validity of a measure designed for COPD, the Seattle Obstructive Lung Disease Questionnaire (SOLQ), in bronchiectasis. In addition, we aimed to compare the quality of life of subjects with bronchiectasis and bronchial hyper-responsiveness with that of those without to identify the effective factors. We studied 78 subjects with clinically stable bronchiectasis and 41 healthy controls matched for age and sex. Subjects were assessed by the SOLQ. A detailed history, physical examination, the Medical Outcomes Study 36-Item Short Form questionnaire, the Hospital Anxiety and Depression Scale, and spirometric measurements were obtained. Cronbach α coefficients, which reflected internal consistency, were >0.70 for all SOLQ components except for treatment satisfaction. SOLQ component scores correlated with all of the component scores of the Medical Outcomes Study 36-Item Short Form questionnaire and the Hospital Anxiety and Depression Scale, confirming their concurrent validity. All SOLQ scores correlated positively with percent-of-predicted FEV1, whereas the physical function, treatment satisfaction, and emotional function correlated negatively with the exacerbation frequency in Pearson analysis. Emotional and physical functions were positively associated with percent-of-predicted FEV1 in linear regression analysis. Compared with subjects without bronchial hyper-responsiveness, those with bronchial hyper-responsiveness had lower FEV1/FVC and more exacerbations/y. Compared with bronchiectasis subjects without bronchial hyper-responsiveness, those with bronchial hyper-responsiveness had significantly lower SOLQ, physical function, and coping skills scores but not emotional function and treatment satisfaction. The SOLQ is a valid instrument for determining quality of life in subjects with bronchiectasis. Subjects with

  20. Impact of forced vital capacity loss on survival after the onset of chronic lung allograft dysfunction.

    Science.gov (United States)

    Todd, Jamie L; Jain, Rahil; Pavlisko, Elizabeth N; Finlen Copeland, C Ashley; Reynolds, John M; Snyder, Laurie D; Palmer, Scott M

    2014-01-15

    Emerging evidence suggests a restrictive phenotype of chronic lung allograft dysfunction (CLAD) exists; however, the optimal approach to its diagnosis and clinical significance is uncertain. To evaluate the hypothesis that spirometric indices more suggestive of a restrictive ventilatory defect, such as loss of FVC, identify patients with distinct clinical, radiographic, and pathologic features, including worse survival. Retrospective, single-center analysis of 566 consecutive first bilateral lung recipients transplanted over a 12-year period. A total of 216 patients developed CLAD during follow-up. CLAD was categorized at its onset into discrete physiologic groups based on spirometric criteria. Imaging and histologic studies were reviewed when available. Survival after CLAD diagnosis was assessed using Kaplan-Meier and Cox proportional hazards models. Among patients with CLAD, 30% demonstrated an FVC decrement at its onset. These patients were more likely to be female, have radiographic alveolar or interstitial changes, and histologic findings of interstitial fibrosis. Patients with FVC decline at CLAD onset had significantly worse survival after CLAD when compared with those with preserved FVC (P model including baseline demographic and clinical factors (P < 0.0001; adjusted hazard ratio, 2.73; 95% confidence interval, 1.86-4.04). At CLAD onset, a subset of patients demonstrating physiology more suggestive of restriction experience worse clinical outcomes. Further study of the biologic mechanisms underlying CLAD phenotypes is critical to improving long-term survival after lung transplantation.

  1. Respiratory muscle hemodynamic and metabolic adaptations to 16 weeks of training in varsity soccer players: near-infrared spectroscopy measurements during lung function tests (Conference Presentation)

    Science.gov (United States)

    Harris, R. Luke; Grob, Tanya; Sandhu, Komal; Schwab, Timothy

    2017-02-01

    The purpose of this study was to test the hypothesis that mobile, wireless near-infrared spectroscopy (NIRS) instruments can be used during standard lung function tests to measure adaptations in respiratory muscle metabolism over weeks to months. In eight varsity soccer players at 0 weeks and after 16 weeks of routine training, commercially available mobile, wireless NIRS instruments were used to measure oxygenation and hemodynamics in the sternocleidomastoid (SCM, accessory inspiration muscle). During maximal expiratory pressure (MEP) and forced vital capacity (FVC) maneuvers we determined peak or antipeak changes relative to baseline in oxygenation and hemodynamics: Δ%Sat (muscle oxygen saturation), ΔtHb (total hemoglobin), ΔO2Hb (oxygenated hemoglobin), and ΔHHb (deoxygenated hemoglobin). Subjects reported that the average training load was 13.3 h/week during the 16 study weeks, compared to 10.4 h/week during 12 prior weeks. After 16 weeks of training compared to 0 weeks we found statistically significant increases in SCM Δ%Sat (57.7%), ΔtHb (55.3%), and ΔO2Hb (56.7%) during MEP maneuvers, and in SCM Δ%Sat (64.8%), ΔtHb (29.4%), and ΔO2Hb (51.6%) during FVC maneuvers. Our data provide preliminary evidence that NIRS measurements during standard lung function tests are sufficiently sensitive to detect improvements or declines in respiratory muscle metabolism over periods of weeks to months due to training, disease, and rehabilitation exercise.

  2. Reference values of fractional excretion of exhaled nitric oxide among non-smokers and current smokers.

    Science.gov (United States)

    Torén, Kjell; Murgia, Nicola; Schiöler, Linus; Bake, Björn; Olin, Anna-Carin

    2017-08-25

    Fractional exhaled nitric oxide (FE NO ) is used to assess of airway inflammation; diagnose asthma and monitor adherence to advised therapy. Reliable and accurate reference values for FE NO are needed for both non-smoking and current smoking adults in the clinical setting. The present study was performed to establish reference adult FE NO values among never-smokers, former smokers and current smokers. FE NO was measured in 5265 subjects aged 25-75 years in a general-population study, using a chemiluminescence (Niox ™) analyser according to the guidelines of the American Thoracic Society and the European Respiratory Society. Atopy was based on the presence of immunoglobulin E (IgE) antibodies to common inhalant allergens (measured using Phadiatop® test). Spirometry without bronchodilation was performed and forced vital capacity (FVC), forced expired volume in 1 s (FEV 1 ) and the ratio of FEV 1 to FVC values were obtained. After excluding subjects with asthma, chronic bronchitis, spirometric airway obstruction and current cold, 3378 subjects remained. Equations for predictions of FE NO values were modelled using nonparametric regression models. FE NO levels were similar in never-smokers and former smokers, and these two groups were therefore merged into a group termed "non-smokers". Reference equations, including the 5th and 95th percentiles, were generated for female and male non-smokers, based on age, height and atopy. Regression models for current smokers were unstable. Hence, the proposed reference values for current smokers are based on the univariate distribution of FE NO and fixed cut-off limits. Reference values for FE NO among respiratory healthy non-smokers should be outlined stratified for gender using individual reference values. For current smokers separate cut-off limits are proposed.

  3. [Factors impacting the growth and nutritional status of cystic fibrosis patients younger than 10 years of age who did not undergo neonatal screening].

    Science.gov (United States)

    Hortencio, Taís Daiene Russo; Nogueira, Roberto José Negrão; Marson, Fernando Augusto de Lima; Hessel, Gabriel; Ribeiro, José Dirceu; Ribeiro, Antônio Fernando

    2015-01-01

    The aim of this study was to evaluate by clinical and laboratory parameters how cystic fibrosis (CF) affects growth and nutritional status of children who were undergoing CF treatment but did not receive newborn screening. A historical cohort study of 52 CF patients younger than 10 years of age were followed in a reference center in Campinas, Southeast Brazil. Anthropometric measurements were abstracted from medical records until March/2010, when neonatal screening program was implemented. Between September/2009 and March/2010, parental height of the 52 CF patients were also measured. Regarding nutritional status, four patients had Z-scores ≤ -2 for height/age (H/A) and body mass index/age (BMI/A). The following variables were associated with improved H/A ratio: fewer hospitalizations, longer time from first appointment to diagnosis, longer time from birth to diagnosis and later onset of respiratory disease. Forced vital capacity [FVC(%)], forced expiratory flow between 25-75% of FVC [FEF25-75(%)], forced expiratory volume in the first second [FEV1(%)], gestational age, birth weight and early respiratory symptoms were associated with IMC/A. Greater number of hospitalizations, diagnosis delay and early onset of respiratory disease had a negative impact on growth. Lower spirometric values, lower gestational age, lower birth weight, and early onset of respiratory symptoms had negative impact on nutritional status. Malnutrition was observed in 7.7% of cases, but 23% of children had nutritional risk. Copyright © 2014 Associação de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  4. The effect of time-of-day and chest physiotherapy on multiple breath washout measures in children with clinically stable cystic fibrosis.

    Science.gov (United States)

    Voldby, Christian; Green, Kent; Rosthøj, Susanne; Kongstad, Thomas; Philipsen, Lue; Buchvald, Frederik; Skov, Marianne; Pressler, Tania; Gustafsson, Per; Nielsen, Kim G

    2018-01-01

    In this pilot study we investigated daytime variation of multiple breath nitrogen washout (N2MBW) measures in children with clinically stable cystic fibrosis. To our knowledge the effect of time-of-day on multiple breath washout measures in patients with cystic fibrosis has not previously been reported. Furthermore, we assessed the influence of chest physiotherapy on N2MBW measures. Ten school children with cystic fibrosis performed N2MBW followed by spirometry and plethysmography in the morning and afternoon at three visits that were one month apart. Chest physiotherapy was performed immediately before the afternoon measurements at visit 2 and immediately before morning and afternoon measurements at visit 3. The influence of time-of-day and chest physiotherapy on the measures was evaluated using linear mixed models. There were adequate quality data from 8 children with median age (range) 9.6 (6.0; 15.1) years. Baseline lung clearance index (LCI) (range) was 9.0 (7.1; 13.0) and baseline FEV1% predicted was 97.5 (78.5; 117.9). No N2MBW measures were significantly influenced by time-of-day or chest physiotherapy. LCI (95% confidence interval) decreased non-significantly 0.05 (-0.32; 0.22) during the day and increased non-significantly 0.08 (-0.26; 0.42) after chest physiotherapy. All spirometric measures were unaffected by time-of-day and chest physiotherapy. For plethysmographic measures FRCpleth decreased significantly (pphysiotherapy performed immediately prior to N2MBW had no consistent or significant influence on N2MBW measures. However, we emphasize that further studies of the effect of both daytime variation and the effect of chest physiotherapy on multiple breath washout measures are warranted.

  5. Lung volumes identify an at-risk group in persons with prolonged secondhand tobacco smoke exposure but without overt airflow obstruction.

    Science.gov (United States)

    Arjomandi, Mehrdad; Zeng, Siyang; Geerts, Jeroen; Stiner, Rachel K; Bos, Bruce; van Koeverden, Ian; Keene, Jason; Elicker, Brett; Blanc, Paul D; Gold, Warren M

    2018-01-01

    Exposure to secondhand smoke (SHS) is associated with occult obstructive lung disease as evident by abnormal airflow indices representing small airway disease despite having preserved spirometry (normal forced expiratory volume in 1 s-to-forced vital capacity ratio, FEV 1 /FVC). The significance of lung volumes that reflect air trapping in the presence of preserved spirometry is unclear. To investigate whether lung volumes representing air trapping could determine susceptibility to respiratory morbidity in people with SHS exposure but without spirometric chronic obstructive pulmonary disease, we examined a cohort of 256 subjects with prolonged occupational SHS exposure and preserved spirometry. We elicited symptom prevalence by structured questionnaires, examined functional capacity (maximum oxygen uptake, VO 2max ) by exercise testing, and estimated associations of those outcomes with air trapping (plethysmography-measured residual volume-to-total lung capacity ratio, RV/TLC), and progressive air trapping with exertion (increase in fraction of tidal breathing that is flow limited on expiration during exercise (per cent of expiratory flow limitation, %EFL)). RV/TLC was within the predicted normal limits, but was highly variable spanning 22%±13% and 16%±8% across the increments of FEV 1 /FVC and FEV 1 , respectively. Respiratory complaints were prevalent (50.4%) with the most common symptom being ≥2 episodes of cough per year (44.5%). Higher RV/TLC was associated with higher OR of reporting respiratory symptoms (n=256; r 2 =0.03; p=0.011) and lower VO 2max (n=179; r 2 =0.47; p=0.013), and %EFL was negatively associated with VO 2max (n=32; r 2 =0.40; p=0.017). In those at risk for obstruction due to SHS exposure but with preserved spirometry, higher RV/TLC identifies a subgroup with increased respiratory symptoms and lower exercise capacity.

  6. Comparison between actual and predicted postoperative stair-climbing test, walk test and spirometric values in patients undergoing lung resection Comparação dos testes de escada, caminhada e espirometria preditos com os obtidos no pós-operatório de ressecções pulmonares

    Directory of Open Access Journals (Sweden)

    Marcos Vinícius Cataneo Pancieri

    2010-12-01

    Full Text Available PURPOSE: To assess whether the tests - Forced Expiratory Volume at one second (FEV1, 6-minute walk test (6MWT and stair-climbing test (SCT showed proportional changes after the resection of functioning lung. METHODS: Candidates for pulmonary resection were included. Spirometry, 6MWT and SCT were performed preoperatively (pre and at least 3 months after surgery (pos. SCT was performed on a staircase with a total ascent height of 12.16m. The time taken to climb the total height the fastest possible was defined as stair-climbing time (SCt. Number of functioning segments lost, was used to calculated predicted postoperative (ppo tests values. Pre, ppo and pos values for each test were compared. Data were analyzed by repeated-measure ANOVA with significance level set at 5%. RESULTS: A total of 40 patients were enrolled. Pulmonary resection results ranged from gain of 2 functioning segments to loss of 9. Pre, ppo and pos values were the following: preFEV1 = 2.6±0.8L, ppo FEV1 =2.3±0.8L, and pos FEV1=2.3±0.8L, (pre FEV1 > ppo FEV1 = pos FEV1; pre6MWT = 604±63m, ppo6MWT= 529±103m, pos6MWT= 599±74m (pre6MWT = pos6MWT > ppo6MWT; preSCt = 32.9±7.6s, ppoSCt = 37.8±12.1s, posSCt = 33.7±8.5s (preSCt = posSCt OBJETIVO: Verificar se os testes: Volume Expiratório Forçado no 1º segundo (VEF1, Teste de Caminhada de 6 minutos (TC6 e Teste de Escada (TE se alteram proporcionalmente ao pulmão funcionante ressecado. MÉTODOS: Foram incluídos pacientes candidatos a toracotomia para ressecção pulmonar. No pré-operatório (pré e no mínimo três meses após a cirurgia (pós, realizaram espirometria, TC6 e TE. O TE foi realizado em escada com 12,16m de altura. O tempo para subir todos os degraus o mais rápido possível foi chamado tempo de escada (tTE. Os cálculos dos valores dos testes preditos para o pós-operatório (ppo foram realizados conforme o número de segmentos funcionantes perdidos. Os valores pré, ppo e pós foram comparados entre si para

  7. Measures of the inflammatory response in cryptogenic fibrosing alveolitis

    International Nuclear Information System (INIS)

    Pantin, C.F.; Valind, S.O.; Sweatman, M.; Lawrence, R.; Rhodes, C.G.; Brudin, L.; Britten, A.; Hughes, J.M.; Turner-Warwick, M.

    1988-01-01

    Cryptogenic fibrosing alveolitis (CFA) is characterized by interstitial fibrosis and parenchymal inflammation. Eleven patients with CFA (10 proved by lung biopsy) were followed over 2 yr using clinical symptoms, radiographic change, and pulmonary function tests to adjust their treatment. Lung lavage, positron camera (PET) measurements of regional extravascular lung density (Dev), pulmonary blood volume (Vb), and the metabolic rate for 18F-deoxyglucose (MRglc), clearance of 99mTc-diethylenetriaminepentacetate (99mTc-DTPA) aerosol, and lung uptake of 67Ga were measured initially and at the end of the first year to give a profile of the inflammatory response. Compared with normal subjects, there was an increased percentage of neutrophils and eosinophils in the lung lavage, increased Dev (p less than 0.002) with no significant difference in Vb, increased MRglc (p less than 0.02), 99mTc-DTPA clearance (p less than 0.002), and 67Ga uptake (p less than 0.02). The smallest increases in Dev were seen in the two patients with most destruction shown by lung biopsy. There were inverse correlations between Dev and both FVC and TLC, but a direct correlation between Vb and transfer factor. 99mTc-DTPA clearance changed concordantly with clinical status and radiographic and respiratory function changes during the first year. If glucose utilization (MRglc) remained in the normal range between the initial and first yearly assessment, the patient improved or remained stable during the second year as shown by clinical status and radiographic and respiratory function measurements. If it rose or remained high, the patient's condition deteriorated

  8. Clinical Utility of Additional Measurement of Total Lung Capacity in Diagnosing Obstructive Lung Disease in Subjects With Restrictive Pattern of Spirometry.

    Science.gov (United States)

    Lee, Hyun; Chang, Boksoon; Kim, Kyunga; Song, Won Jun; Chon, Hae Ri; Kang, Hyung Koo; Kim, Jung Soo; Jeong, Byeong-Ho; Oh, Yeon-Mok; Koh, Won-Jung; Park, Hye Yun

    2016-04-01

    Total lung capacity (TLC), forced expiratory flow between 25 and 75% (FEF25-75%), peak expiratory flow (PEF), or post-bronchodilator volume response is recommended to detect obstructive abnormalities in the lung. The present study was performed to evaluate the usefulness of these pulmonary function test (PFT) parameters to diagnose obstructive lung disease in subjects with a restrictive pattern of spirometry. A retrospective study was conducted in 64 subjects with a restrictive pattern of spirometry (normal FEV1/FVC and low FVC) out of 3,030 patients who underwent all pre- and post-bronchodilator spirometry and lung volume measurement between April 2008 and December 2010. After subjects were clinically classified into those with obstructive lung disease, restrictive lung disease, and mixed lung disease, the agreements between the clinical diagnosis and PFT classification according to TLC, FEF(25-75%), PEF, and post-bronchodilator response criteria were compared. Of 64 subjects, 18 (28.1%) were classified with obstructive lung disease, 39 (60.9%) had restrictive lung disease, 1 (1.6%) had mixed lung disease, and 6 (9.4%) had no clinical lung disease. Among the 58 subjects with clinical lung disease, 22 (37.9%), 37 (63.8%), 33 (56.9%), and 3 (5.2%) were classified as having obstructive pattern based on TLC, FEF25-75%, PEF, and post-bronchodilator response criteria, respectively. The kappa coefficients for the agreement between the clinical classification and PFT classification using TLC, FEF25-75%, PEF, and post-bronchodilator response criteria in 58 subjects were 0.59, 0.18, 0.17, and spirometry, when obstructive lung disease is clinically suspected. Copyright © 2016 by Daedalus Enterprises.

  9. PIKO-6® vs. forced spirometry in asthmatic children.

    Science.gov (United States)

    Gochicoa-Rangel, Laura; Larios-Castañeda, Pablo José; Miguel-Reyes, José Luis; Briseño, David Martínez; Flores-Campos, Roberto; Sáenz-López, Juan Arturo; Torre-Bouscoulet, Luis

    2014-12-01

    The PIKO-6® is an electronic device that measures forced expiratory volume at seconds 1 (FEV1) and 6 (FEV6) of a forced vital capacity (FVC) maneuver. This device could aid in diagnosing obstructive respiratory diseases. To determine the concordance of FEV1, FEV6, and the FEV1/FEV6 quotient achieved with PIKO-6® versus spirometric values from asthmatic patients, and compare results with measures from healthy children. A cross-sectional study with asthmatic and healthy 6-to-14-year-old children, all of whom performed a forced spirometry as well as a PIKO-6® test. The study included 82 subjects (58 asthmatics, 24 healthy children). Except for the functional parameters, the basal characteristics of the two groups were similar. The concordance correlation coefficient (CCC) for FEV1 was 0.938 (P spirometry was lower in patients with partially controlled or uncontrolled asthma compared to controlled or healthy children. The broad limits of agreement show that the FEV1, FEV6, and FEV1/FEV6 obtained with the PIKO-6® are not interchangeable with spirometry results. Longitudinal evaluations of asthma patients are necessary to assess the utility of PIKO-6®. © 2014 Wiley Periodicals, Inc.

  10. Leukotriene-B4 concentrations in exhaled breath condensate and lung function after thirty minutes of breathing technically dried compressed air.

    Science.gov (United States)

    Neubauer, Birger; Struck, Niclas; Mutzbauer, Till S; Schotte, Ulrich; Langfeldt, Norbert; Tetzlaff, Kay

    2002-01-01

    In previous studies it had been shown that leukotriene-B4 [LTB4] concentrations in the exhaled breath mirror the inflammatory activity of the airways if the respiratory tract has been exposed to occupational hazards. In diving the respiratory tract is exposed to cold and dry air and the nasopharynx, as the site of breathing-gas warming and humidification, is bypassed. The aim of the present study was to obtain LTB4-concentrations in the exhaled breath and spirometric data of 17 healthy subjects before and after thirty minutes of technically dried air breathing at normobar ambient pressure. The exhaled breath was collected non-invasively, via a permanently cooled expiration tube. The condensate was measured by a standard enzyme immunoassay for LTB4. Lung function values (FVC, FEV1, MEF 25, MEF 50) were simultaneously obtained by spirometry. The measured pre- and post-exposure LTB4- concentrations as well as the lung function values were in the normal range. The present data gave no evidence for any inflammatory activity in the subjects' airways after thirty minutes breathing technically dried air.

  11. Cardio-respiratory response of young adult Indian male subjects to stress: Effects of progressive muscle relaxation

    Directory of Open Access Journals (Sweden)

    Arunima Chaudhuri

    2014-01-01

    Full Text Available Background: Stress and anxiety have become an integral part of our lives. Of late, this has resulted in the increase in incidence of hypertension and coronary heart disease. Objectives: To assess the effect of progressive muscle relaxation (PMR on young adult males and its role in the modulation of cardio-respiratory response on exposure to stress. Materials and Methods: This prospective cross-sectional study was conducted in a tertiary care referral hospital. Undergraduate male students under stress were chosen for the study. Fasting blood samples were drawn to analyze sugar and lipid profile, followed by anthropometric measurements and ECG. In the resting condition, blood pressure, pulse rate, and spirometric parameters; forced vital capacities (FVC, and forced expiratory volume in 1 sec (FEV 1 % were measured. Then, they were made to exercise with bicycle ergometer and post exercise, the vital parameters were recorded. All subjects were given a training of Jacobson′s Progressive Muscular Relaxation and asked to practice this technique for 3 months. All parameters were re-evaluated. Results: Significant decreases in resting heart rate, systolic blood pressure and diastolic blood pressure, total cholesterol, triglyceride, and low density lipoprotein (LDL cholesterol levels of subjects were seen after PMR training. Exercise-induced rise in heart rate and blood pressure were also significantly less in subjects following PMR training. Conclusion: Progressive muscle relaxation helps in modulation of heart rate, blood pressure, and lipid profile in healthy normal adult male individuals.

  12. Poor sleep quality has an adverse effect on childhood asthma control and lung function measures.

    Science.gov (United States)

    Sheen, Youn Ho; Choi, Sun Hee; Jang, Sun Jung; Baek, Ji Hyeon; Jee, Hye Mi; Kim, Mi Ae; Chae, Kyu Young; Han, Man Yong

    2017-08-01

    It is unclear as to whether sleep respiratory breathing disorder (SRBD) is a risk factor for uncontrolled asthma in children. The aim of this study was therefore to investigate whether SRBD may have an adverse effect on childhood asthma control and lung function measures. This was a cross-sectional study of 220 children with well-controlled (n = 108), partly controlled (n = 92), and uncontrolled asthma (n = 20) according to the Global Initiative for Asthma guideline. SRBD was assessed using the Pediatric Sleep Questionnaire (PSQ). The association of SRBD with partly controlled/uncontrolled asthma was investigated on multivariate logistic regression analysis. Of 220 children with asthma, 43 (19.6%) had SRBD: well-controlled, 16.7% (18/108); partly controlled, 21.7% (20/92); and uncontrolled, 25.0% (5/20; P = 0.54). There was a significant difference in forced expiratory volume in 1 s/forced vital capacity (FEV 1 /FVC; P = 0.007) and childhood asthma control test (C-ACT) score (P asthma control status, but not in PSQ score (P = 0.18). Children with obstructive sleep apnea (PSQ >0.33) had a lower C-ACT score compared with controls (PSQ ≤0.33; 19.6 ± 5.1 vs 22.0 ± 4.2, P = 0.002). PSQ score was negatively correlated with FEV 1 /FVC (r = -0.16, P = 0.02). On multivariate logistic regression analysis, high PSQ score increased the odds of having partly controlled/uncontrolled asthma by 9.12 (95% CI: 1.04-79.72, P = 0.046) after adjusting for confounding factors. SRBD is an independent risk factor for partly controlled/uncontrolled asthma and has an adverse effect on lung function measures in children. Further research is warranted to determine whether the improvement of sleep quality may also enhance level of asthma control and lung function in children. © 2017 Japan Pediatric Society.

  13. Smoking and spirometric values in third year medical students: cross-sectional study

    OpenAIRE

    10.5867/medwave.2015.03.6124; Mariela Edith Beligoy; Yessica Vanesa Lima; Pablo Federico Barissi

    2015-01-01

    OBJETIVO El presente estudio tiene por objetivo conocer la frecuencia de tabaquismo y su relación con los indicadores de la función respiratoria, además de los hábitos y las actitudes respecto al consumo de cigarrillos en estudiantes de tercer año de la carrera de Medicina del Instituto Universitario de Ciencias de la Salud, Fundación Héctor A. Barceló, sede Santo Tomé, Corrientes, Argentina. MÉTODOS Estudio de corte transversal y analítico, con estudiantes de tercer año de la carre...

  14. The Evaluation of Relationship between Spirometric Disorders and Methyl methacrylate in Dental Laboratories Personnel

    OpenAIRE

    E. Nadi; M.J. Asari; A. Zamanian

    2010-01-01

    Introduction & Objective: Methyl methacrylate (MMA), as a monomer of acrylic resin that has a wide variety of usages in denture fabrication, is considered as an air pollution indicator in the laboratories. Occupational exposure to these compound vapors can cause respiratory hypersensitivity, occupational asthma, eye and skin irritation and Allergic Contact Dermatitis (ACD). Therefore control of MMA exposure may promote the personnel’s health. The aim of this study was to determine the relati...

  15. SPIROMETRIC EVALUATION OF LUNG FUNCTION OF COAL WORKERS WORKING AT MACH (BOLAN DISTRICT)

    OpenAIRE

    Ghulam Sarwar, Muhammad Younis, Shafi Muhammad, Tanzeel Ahmed*, Muhammad Siddique, Bashir Ahmed, Munir Ahmed, Jahanzaib

    2017-01-01

    To evaluate the coal dust effect on lung function among coal workers and non-coal workers. This was case-control study. The 144 male coal workers and non-coal workers, 20-50 years more than one year of working skill were selected. Study was carried out in the Mach, Bolan district in Balochistan, Pakistan. The Spirometer and selfdesigned survey form were used. The interview was accompanied and information was documented in the survey form and Spirometry was done for coal workers and non-coal w...

  16. Smoking and spirometric values in third year medical students: cross-sectional study

    Directory of Open Access Journals (Sweden)

    10.5867/medwave.2015.03.6124

    2015-04-01

    Full Text Available OBJETIVO El presente estudio tiene por objetivo conocer la frecuencia de tabaquismo y su relación con los indicadores de la función respiratoria, además de los hábitos y las actitudes respecto al consumo de cigarrillos en estudiantes de tercer año de la carrera de Medicina del Instituto Universitario de Ciencias de la Salud, Fundación Héctor A. Barceló, sede Santo Tomé, Corrientes, Argentina. MÉTODOS Estudio de corte transversal y analítico, con estudiantes de tercer año de la carrera de Medicina, durante las dos primeras semanas de octubre de 2014. Se agruparon en fumadores y no fumadores realizándose la espirometría mediante espirómetro computarizado Flowmax 2, según los parámetros de la Asociación Americana de Tórax. Se aplicó un cuestionario con 36 preguntas incluyendo el test de Fagerström. RESULTADOS En los 227 alumnos se observó una edad promedio de 22,5 ± 3,81 años siendo el 52,9% mujeres y el 47,1% varones. El 26,4% eran fumadores con predominio de varones y con un mayor consumo de cigarrillos que las mujeres. Un 5% de los fumadores presentó patrón espirométrico obstructivo con una asociación significativa (p = 0,017 entre el fumar y la alteración espirométrica. El 25% de los varones y el 8,4% de las mujeres, presentaron un grado de dependencia física media o alta al tabaco. El 18,6% de los no fumadores habían dejado de fumar desde hace un año o más principalmente para mejorar su salud. CONCLUSIÓNES Es importante incentivar a los estudiantes a dejar de fumar, así como la toma de conciencia de que fumar cerca de otras personas o estar cerca de fumadores es perjudicial para la salud. El futuro médico debe conocer las consecuencias asociadas al hábito de fumar y la importancia de prevenir y concientizar a los pacientes actuando como modelo a seguir desde los inicios en sus estudios de la Medicina.

  17. Oscillometric and Spirometric Bronchodilator Response in Preschool Children with and without Asthma

    Directory of Open Access Journals (Sweden)

    Youn Ho Shin

    2012-01-01

    Full Text Available BACKGROUND: Bronchodilator responses (BDR are routinely used in the diagnosis and management of asthma; however, their acceptability and repeatability have not been evaluated using quality control criteria for preschool children.

  18. Correlation of ultra-low dose chest CT findings with physiologic measures of asbestosis

    Energy Technology Data Exchange (ETDEWEB)

    Manners, David [Sir Charles Gairdner Hospital, Department of Respiratory Medicine, Nedlands, WA (Australia); Wong, Patrick; Murray, Conor; Teh, Joelin [Royal Perth Hospital, Department of Diagnostic Imaging, Perth (Australia); Kwok, Yi Jin [Sir Charles Gairdner Hospital, Department of Diagnostic Imaging, Nedlands, WA (Australia); De Klerk, Nick; Franklin, Peter [University of Western Australia, School of Population Health, Perth, WA (Australia); Alfonso, Helman; Reid, Alison [Curtin University, School of Public Health, Perth, WA (Australia); Musk, A.W.B. [Sir Charles Gairdner Hospital, Department of Respiratory Medicine, Nedlands, WA (Australia); University of Western Australia, School of Population Health, Perth, WA (Australia); University of Western Australia, School of Medicine and Pharmacology, Perth, WA (Australia); Brims, Fraser J.H. [Sir Charles Gairdner Hospital, Department of Respiratory Medicine, Nedlands, WA (Australia); University of Western Australia, School of Population Health, Perth, WA (Australia); Curtin University, Curtin Medical School, Perth (Australia)

    2017-08-15

    The correlation between ultra low dose computed tomography (ULDCT)-detected parenchymal lung changes and pulmonary function abnormalities is not well described. This study aimed to determine the relationship between ULDCT-detected interstitial lung disease (ILD) and measures of pulmonary function in an asbestos-exposed population. Two thoracic radiologists independently categorised prone ULDCT scans from 143 participants for ILD appearances as absent (score 0), probable (1) or definite (2) without knowledge of asbestos exposure or lung function. Pulmonary function measures included spirometry and diffusing capacity to carbon monoxide (DLCO). Participants were 92% male with a median age of 73.0 years. CT dose index volume was between 0.6 and 1.8 mGy. Probable or definite ILD was reported in 63 (44.1%) participants. Inter-observer agreement was good (k = 0.613, p < 0.001). There was a statistically significant correlation between the ILD score and both forced expiratory volume in 1 second (FEV{sub 1}) and forced vital capacity (FVC) (r = -0.17, p = 0.04 and r = -0.20, p = 0.02). There was a strong correlation between ILD score and DLCO (r = -0.34, p < 0.0001). Changes consistent with ILD on ULDCT correlate well with corresponding reductions in gas transfer, similar to standard CT. In asbestos-exposed populations, ULDCT may be adequate to detect radiological changes consistent with asbestosis. (orig.)

  19. Correlation of ultra-low dose chest CT findings with physiologic measures of asbestosis

    International Nuclear Information System (INIS)

    Manners, David; Wong, Patrick; Murray, Conor; Teh, Joelin; Kwok, Yi Jin; De Klerk, Nick; Franklin, Peter; Alfonso, Helman; Reid, Alison; Musk, A.W.B.; Brims, Fraser J.H.

    2017-01-01

    The correlation between ultra low dose computed tomography (ULDCT)-detected parenchymal lung changes and pulmonary function abnormalities is not well described. This study aimed to determine the relationship between ULDCT-detected interstitial lung disease (ILD) and measures of pulmonary function in an asbestos-exposed population. Two thoracic radiologists independently categorised prone ULDCT scans from 143 participants for ILD appearances as absent (score 0), probable (1) or definite (2) without knowledge of asbestos exposure or lung function. Pulmonary function measures included spirometry and diffusing capacity to carbon monoxide (DLCO). Participants were 92% male with a median age of 73.0 years. CT dose index volume was between 0.6 and 1.8 mGy. Probable or definite ILD was reported in 63 (44.1%) participants. Inter-observer agreement was good (k = 0.613, p < 0.001). There was a statistically significant correlation between the ILD score and both forced expiratory volume in 1 second (FEV 1 ) and forced vital capacity (FVC) (r = -0.17, p = 0.04 and r = -0.20, p = 0.02). There was a strong correlation between ILD score and DLCO (r = -0.34, p < 0.0001). Changes consistent with ILD on ULDCT correlate well with corresponding reductions in gas transfer, similar to standard CT. In asbestos-exposed populations, ULDCT may be adequate to detect radiological changes consistent with asbestosis. (orig.)

  20. Emphysema in heavy smokers with normal chest radiography

    International Nuclear Information System (INIS)

    Sashidhar, K.; Monga, S.; Suri, S.; Gulati, M.; Gupta, D.

    2002-01-01

    Purpose: To determine the severity and extent of emphysema in heavy smokers by high-resolution CT (HRCT) and to correlate the findings with spirometric tests (STs) and symptomatology. Material and Methods: Fifty adult smokers with a mean age of 53 years with a smoking history of more than 30 pack years and normal chest radiographs underwent HRCT of the chest and ST (FEV1, FEV1/FVC, PEFR). Among these, 22 had symptoms of pulmonary disease and 28 were asymptomatic. Quantification of emphysema was done using a density mask program and the visual scoring method. The results were correlated with ST and symptomatology. Results: 58% (29 out of 50) of the subjects had significant emphysema on HRCT. Eleven out of 15 with normal ST showed emphysema on HRCT while 2 with airflow obstruction on ST showed normal CT scores. 14% (4 out of 28) asymptomatic subjects had severe emphysema compared to 64% of symptomatic subjects. Emphysematous changes were predominantly seen in upper lung zones in 48% of the patients while in 52% it was distributed equally in both upper and lower zones. The number of pack years of smoking showed a positive correlation with CT scores. The correlation between HRCT scores and ST was statistically significant. Conclusion: A significant number of asymptomatic and clinically undiagnosed smokers tend to have significant emphysema. HRCT helps in early detection of disease and thus helps implementation of preventive measures

  1. Comparative assessment of respiratory and other occupational health effects among elementary workers.

    Science.gov (United States)

    Hamid, Almas; Saleem, Wajeeha; Yaqub, Ghazala; Ghauri, Moin Ud Din

    2017-12-14

    This study was conducted to assess hazards faced by elementary workers. A questionnaire survey and a respiratory function test (spirometry) were carried out on 150 respondents. Major hazards identified related to sharp objects, heavy weight lifting, thermally harsh conditions, working at height, whole body vibration, chemicals, pathogens, increased noise levels and confined space entry. Workers suffered from upper and lower respiratory disorder symptoms, digestive problems, optical and musculoskeletal issues, etc. Spirometric measurement showed obstructive lung disorders to be highest among construction workers (CW) (48%) followed by sanitation workers (SW) (32%) and solid waste pickers (SWP) (28%). Restrictive lung pattern was dominant among SW (56%) followed by SWP (46%) and CW (42%). The observed FEV 1 /FVC in diseased SWP, SW and CW ranged from 51 to 96%, from 52 to 98% and from 31 to 99% respectively while observed mean FEV 1 was 2.15, 1.79 and 1.70 L, respectively. The study findings show that occupational exposure can significantly influence respiratory system impairment and contribute to other ailments among elementary workers. The study recommends use of appropriate protective equipment and regular medical examination for early recognition of any health risk so that timely interventions for effective management may be undertaken.

  2. Variability in childhood allergy and asthma across ethnicity, language, and residency duration in El Paso, Texas: a cross-sectional study.

    Science.gov (United States)

    Svendsen, Erik R; Gonzales, Melissa; Ross, Mary; Neas, Lucas M

    2009-12-08

    We evaluated the impact of migration to the USA-Mexico border city of El Paso, Texas (USA), parental language preference, and Hispanic ethnicity on childhood asthma to differentiate between its social and environmental determinants. Allergy and asthma prevalence was surveyed among 9797 fourth and fifth grade children enrolled in the El Paso Independent School District. Parents completed a respiratory health questionnaire, in either English or Spanish, and a sub-sample of children received spirometry testing at their school. Here we report asthma and allergy outcomes across ethnicity and El Paso residency duration. Asthma and allergy prevalence increased with longer duration of El Paso residency independent of ethnicity and preferred language. Compared with immigrants who arrived in El Paso after entering first grade (18%), lifelong El Paso residents (68%) had more prevalent allergy (OR, 1.72; 95% CI, 1.32 - 2.24), prevalent asthma (OR, 1.75; 95% CI, 1.24 - 2.46), and current asthma (OR, 2.01; 95% CI, 1.37 - 2.95). Spirometric measurements (FEV1/FVC and FEF25-75) also declined with increasing duration of El Paso residency (0.16% and 0.35% annual reduction, respectively). These findings suggest that a community-wide environmental exposure in El Paso, delayed pulmonary development, or increased health of immigrants may be associated with allergy and asthma development in children raised there.

  3. Air pollution and fuel vapour induced changes in lung functions: are fuel handlers safe?

    Science.gov (United States)

    Chawla, Anuj; Lavania, A K

    2008-01-01

    Automobile exhaust derived air pollutants have become a major health hazard. Coupled with the inhalation of fuel vapour, as occurs in petrol station workers, this may lead to significant impairment of lung function. Spirometric lung functions were studied in 58 petrol station workers to examine this possibility. The forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), forced expiratory flow 25%-75% (FEF25-75) and peak expiratory flow (PEF) were recorded and analysed separately for smokers and non-smokers. The workers were divided into 5 groups for analysis of data based on the number of years of work in the petrol pumps. Outdoor air analysis was also carried out. The FVC, FEV1 and PEF declined significantly with increasing years of work in petrol stations in both smokers and non-smokers. Smoking as an independent variable was found to affect the FEV1 significantly but not FVC or PEF. The FEF25-75 was found to be the most affected spirometric value with a significant reduction with increasing years of work. Smoking as such did not affect it. Oxides of nitrogen (NOx), suspended particulate matter (SPM) and particulate matter less than 10 microns (PM10) in outdoor air were higher than the national ambient air quality standards. Exposure to automobile exhaust and fuel vapour impairs lung function in a time-dependent manner. Cigarette smoking appears to accelerate the decline.

  4. The recent multi-ethnic global lung initiative 2012 (GLI2012) reference values don't reflect contemporary adult's North African spirometry.

    Science.gov (United States)

    Ben Saad, Helmi; El Attar, Mohamed Nour; Hadj Mabrouk, Khaoula; Ben Abdelaziz, Ahmed; Abdelghani, Ahmed; Bousarssar, Mohamed; Limam, Khélifa; Maatoug, Chiraz; Bouslah, Hmida; Charrada, Ameur; Rouatbi, Sonia

    2013-12-01

    The applicability of the recent multi-ethnic reference equations derived by the ERS Global Lung Initiative (ERS/GLI) in interpreting spirometry data in North African adult subjects has not been studied. To ascertain how well the recent ERS/GLI reference equations fit contemporary adult Tunisian spirometric data. Spirometric data were recorded from 1192 consecutive spirometry procedures in adults aged 18-60 years. Reference values and lower limits of normality (LLN) were calculated using the local and the ERS/GLI reference equations. Applied definitions: large airway obstructive ventilatory defect (LAOVD): FEV1/FVC contemporary Tunisian spirometry. Using Tunisian reference equations, 71.31%, 6.71% and 19.04% of spirometry records were interpreted as normal, and as having, LAOVD and TRVD, respectively. Using the ERS/GLI reference equations, these figures were respectively, 85.82%, 4.19% and 8.39%. The mean ± SD Z-scores for the contemporary healthy North African subject's data were -0.55 ± 0.87 for FEV1, -0.62 ± 0.86 for FVC and 0.10 ± 0.73 for FEV1/FVC. The present study don't recommend the use of the recent ERS/GLI reference equations to interpret spirometry in North African adult population. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Importance measures

    International Nuclear Information System (INIS)

    Gomez Cobo, A.

    1997-01-01

    The presentation discusses the following: general concepts of importance measures; example fault tree, used to illustrate importance measures; Birnbaum's structural importance; criticality importance; Fussel-Vesely importance; upgrading function; risk achievement worth; risk reduction worth

  6. Formative (measurement)

    NARCIS (Netherlands)

    Fassott, G.; Henseler, Jörg; Cooper, C.; Lee, N.; Farrell, A.

    2015-01-01

    When using measurement models with multiple indicators, researchers need to decide about the epistemic relationship between the latent variable and its indicators. In this article, we describe the nature, the estimation, the characteristics, and the validity assessment of formative measurement

  7. Measurement evaluation

    CERN Document Server

    Boros, A

    1990-01-01

    The information obtained about a measured object is called ``crude'' measurement information and must be related to the conditions under which the measurement took place. Using ``crude'' measurement information as a starting point, evaluation produces physically correctly interpreted data with their estimated (or corrected) error. Although a number of works deal with the evaluation of measurements, they either appeared a long time ago or serve essentially different aims. This book gives a comprehensive and current overview on the basic principles, aids, devices, and methods in the eval

  8. Childhood-onset asthma in smokers. association between CT measures of airway size, lung function, and chronic airflow obstruction.

    Science.gov (United States)

    Diaz, Alejandro A; Hardin, Megan E; Come, Carolyn E; San José Estépar, Raúl; Ross, James C; Kurugol, Sila; Okajima, Yuka; Han, MeiLan K; Kim, Victor; Ramsdell, Joe; Silverman, Edwin K; Crapo, James D; Lynch, David A; Make, Barry; Barr, R Graham; Hersh, Craig P; Washko, George R

    2014-11-01

    Asthma is associated with chronic airflow obstruction. Our goal was to assess the association of computed tomographic measures of airway wall volume and lumen volume with the FEV1 and chronic airflow obstruction in smokers with childhood-onset asthma. We analyzed clinical, lung function, and volumetric computed tomographic airway volume data from 7,266 smokers, including 590 with childhood-onset asthma. Small wall volume and small lumen volume of segmental airways were defined as measures 1 SD below the mean. We assessed the association between small wall volume, small lumen volume, FEV1, and chronic airflow obstruction (post-bronchodilator FEV1/FVC ratio childhood-onset asthma, those with childhood-onset asthma had smaller wall volume and lumen volume (P childhood-onset asthma, those with the smallest wall volume and lumen volume had the lowest FEV1 and greatest odds of chronic airflow obstruction. A similar tendency was seen in those without childhood-onset asthma. When comparing these two groups, both small wall volume and small lumen volume were more strongly associated with FEV1 and chronic airflow obstruction among subjects with childhood-asthma in multivariate models. In smokers with childhood-onset asthma, smaller airways are associated with reduced lung function and chronic airflow obstruction. Clinical trial registered with www.clinicaltrials.gov (NCT00608764).

  9. Quantum measurement

    CERN Document Server

    Busch, Paul; Pellonpää, Juha-Pekka; Ylinen, Kari

    2016-01-01

    This is a book about the Hilbert space formulation of quantum mechanics and its measurement theory. It contains a synopsis of what became of the Mathematical Foundations of Quantum Mechanics since von Neumann’s classic treatise with this title. Fundamental non-classical features of quantum mechanics—indeterminacy and incompatibility of observables, unavoidable measurement disturbance, entanglement, nonlocality—are explicated and analysed using the tools of operational quantum theory. The book is divided into four parts: 1. Mathematics provides a systematic exposition of the Hilbert space and operator theoretic tools and relevant measure and integration theory leading to the Naimark and Stinespring dilation theorems; 2. Elements develops the basic concepts of quantum mechanics and measurement theory with a focus on the notion of approximate joint measurability; 3. Realisations offers in-depth studies of the fundamental observables of quantum mechanics and some of their measurement implementations; and 4....

  10. Measurement Uncertainty

    Science.gov (United States)

    Koch, Michael

    Measurement uncertainty is one of the key issues in quality assurance. It became increasingly important for analytical chemistry laboratories with the accreditation to ISO/IEC 17025. The uncertainty of a measurement is the most important criterion for the decision whether a measurement result is fit for purpose. It also delivers help for the decision whether a specification limit is exceeded or not. Estimation of measurement uncertainty often is not trivial. Several strategies have been developed for this purpose that will shortly be described in this chapter. In addition the different possibilities to take into account the uncertainty in compliance assessment are explained.

  11. The Glittre-ADL test reflects functional performance measured by physical activities of daily living in patients with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Manuela Karloh

    2016-01-01

    Full Text Available ABSTRACT Background The Glittre-ADL test (TGlittre is a valid and reliable test for the evaluation of functional capacity and involves multiple physical activities of daily living (PADL, which are known to be troublesome to patients with Chronic Obstructive Pulmonary Disease (COPD. However, it is still unknown if this test is also able to reflect the functional performance of patients with COPD. Objective To investigate whether the TGlittre reflects the functional performance of COPD patients and whether the necessary time to complete the TGlittre and the PADL varies according to disease severity. Method Thirty-eight patients with COPD (age 65, SD=7 years; forced expiratory volume in the first second 41.3, SD=15.2% predicted underwent anthropometric and lung function assessments and were submitted to the TGlittre and PADL measurement. Results TGlittre performance correlated significantly (p<0.05 with PADL variables, such as time sitting (r=0.50, walking (r=-0.46, number of steps taken (r=–0.53, walking movement intensity (r=–0.66, walking energy expenditure (r=-0.50, and total energy expenditure (r=–0.33. TGlittre performance was not significantly different in patients among the Global Initiative for COPD (GOLD spirometric stages, but walking and sitting time were significantly lower and greater, respectively, in severe and very severe patients compared to those with moderate disease (p<0.05. Conclusion The performance on the TGlittre correlates with walking and sitting time and other real life PADL measurements. The severity of the disease is associated with the differences in the level of physical activity in daily life more than in functional capacity.

  12. Measuring Colour

    CERN Document Server

    Hunt, R W G

    2011-01-01

    The classic authority on colour measurement now fully revised and updated with the latest CIE recommendations The measurement of colour is of major importance in many commercial applications, such as the textile, paint, and foodstuff industries; as well as having a significant role in the lighting, paper, printing, cosmetic, plastics, glass, chemical, photographic, television, transport, and communication industries. Building upon the success of earlier editions, the 4th edition of Measuring Colour has been updated throughout with new chapters on colour rendering by light sources; colorimetry

  13. Mechanical measurements

    CERN Document Server

    Venkateshan, S P

    2015-01-01

    The first edition of this book was co-published by Ane Books India, and CRC Press in 2008. This second edition is an enlarged version of the web course developed by the author at IIT Madras, and also a modified and augmented version of the earlier book.  Major additions/modifications presented are in the treatment of errors in measurement, temperature measurement, measurement of thermo-physical properties, and data manipulation. Many new worked examples have been introduced in this new and updated second edition. 

  14. Horizon measures

    KAUST Repository

    Zhang, Eugene

    2016-11-28

    In this paper we seek to answer the following question: where do contour lines and visible contour lines (silhouette) tend to occur in a 3D surface. Our study leads to two novel shape descriptors, the horizon measure and the visible horizon measure, which we apply to the visualization of 3D shapes including archeological artifacts. In addition to introducing the shape descriptors, we also provide a closed-form formula for the horizon measure based on classical spherical geometry. To compute the visible horizon measure, which depends on the exact computation of the surface visibility function, we instead of provide an image-based approach which can process a model with high complexity within a few minutes.

  15. Lifetime measurements

    International Nuclear Information System (INIS)

    Poletti, A.R.

    1976-01-01

    Recent developments in experimental methods of measuring the lifetimes of excited nuclear states is reviewed in three main areas. (a) Doppler Shift Attenuation Measurements (DSAM) Times: 10 -14 - 10 -11 sec.; (b) Recoil Distance Measurements (RDM) Times: 10 -9 - 10 -12 sec.; (c) Direct Electronic Timing Times: down to 10 -10 sec.; A measurement of an excited state lifetime can answer a large number of different questions. Two examples are discussed: (a) The determination of the lifetime of an isomeric transition in 93 Tc and its use in determining an upper limit for the magnitude of the parity non-conserving matrix element - /Hsub(PN)/17/2 + >. (b) The dependence of the strength of M2 transitions on isospin in nuclei in the 1dsub(3/2) -1fsub(7/2) region. (author)

  16. MEASURING CIRCUIT

    Science.gov (United States)

    Mahoney, J.R.

    1963-01-29

    A measuring and balancing arrangement for mass spectrometers permits the ready determination of isotopic ratios and mole and weight percentages by employing a selection of amplifier input resistors to vary sensitivity in a bridge arrangement. (AEC)

  17. Measuring colour

    National Research Council Canada - National Science Library

    Hunt, R. W. G; Pointer, Michael, Ph. D

    2011-01-01

    ... industries.Building upon the success of earlier editions, the 4th edition of [start italics]Measuring Colour[end italics] has been updated throughout with new chapters on colour rendering by light sources...

  18. Diversity Measures

    Directory of Open Access Journals (Sweden)

    MSc. Mentor Ademaj

    2012-06-01

    Full Text Available Diversity measures are a type of non-criminal measures foreseen in the Chapter IV of the Code of Juvenile Justice, which may be imposed on juvenile perpetrators of criminal acts. These measures can be applied in cases of minor offenses, for which is foreseen the criminal sanction with a fine or imprisonment up to three years or for criminal offenses committed by negligence for which is foreseen the sentence up to five years of imprisonment, except those cases that result in death. With the imposition of these measures is intended to prevent criminal proceedings against juveniles whenever is possible, rehabilitation and reintegration of juvenile in his/her community and the prevention of recidivist behaviour. Competent authority to impose them is the public prosecutor, the juvenile judge and juvenile court. And they are executed by the Kosovo Correctional Service.

  19. Lifetime measurements

    International Nuclear Information System (INIS)

    Fossan, D.B.; Warburton, E.K.

    1974-01-01

    Lifetime measurements are discussed, concentrating on the electronic technique, the recoil distance method (RDM), and the Doppler shift attenuation method (DSAM). A brief review of several indirect timing techniques is given, and their specific advantages and applicability are considered. The relationship between lifetimes of nuclear states and the nuclear structure information obtained from them is examined. A short discussion of channeling and microwave methods of lifetime measurement is presented. (23 figures, 171 references) (U.S.)

  20. Anthropomorphic measurements

    International Nuclear Information System (INIS)

    Wang, J.

    1998-01-01

    Based on decisions taken during the Research Coordination Meetings in Mito City 1988 and Bombay 1991, the participants were requested to provide data on physical measurement parameters of body height, body weight, sitting height, head circumference, neck circumference, chest circumference, chest width and chest depth which represented the age groups as newborn, 1 year, 5 years, 10 years, 15 years and adult 20-50 years. Accordingly, physical measurement data was obtained by participants from 9 countries

  1. Against 'measurement'

    International Nuclear Information System (INIS)

    Bell, John

    1990-01-01

    This author of this article rails against the term ''measurement'' as it is commonly used in quantum mechanics. Many terms such as this are full of common place, everyday associations which are entirely inappropriate to the quantum world and lead to misunderstanding even amongst physicists. Measurement implies, at least for laboratory experiments, that the complexities of the real world have been simplified to the minimum number of variables. This can never be so for quantum mechanics where the act of measurement is intrinsic to the result, where even the mind of the observer plays a part. Three books on quantum mechanics are reviewed in an attempt to present a more precise comprehension of the meaning inside quantum mechanics. (UK)

  2. Measurements of

    CERN Document Server

    Angerami, Aaron; The ATLAS collaboration

    2018-01-01

    A measurement is presented of $\\gamma \\gamma \\rightarrow \\mu^{+} \\mu^{-}$ in Pb+Pb collisions recorded by the ATLAS detector at the LHC at $\\sqrt{s_{\\mathrm{NN}}}=5.02$ TeV with an integrated luminosity of 0.49 nb$^{-1}$. The angular and transverse momentum correlations between the muons are measured as a function of collision centrality. The lepton pairs are produced from $\\gamma \\gamma$ through the interaction of the large electromagnetic fields of the nuclei. The contribution from background sources of muon pairs is removed using a template fit method. In peripheral collisions, the muons exhibit a strong back-to-back correlation consistent with previous measurements of muon pair production in ultra-peripheral collisions. The angular correlations are observed to broaden significantly in central collisions. The modifications are qualitatively consistent with rescattering of the muons while passing through the hot matter produced in the collision.

  3. Microwave Measurements

    CERN Document Server

    Skinner, A D

    2007-01-01

    The IET has organised training courses on microwave measurements since 1983, at which experts have lectured on modern developments. Their lecture notes were first published in book form in 1985 and then again in 1989, and they have proved popular for many years with a readership beyond those who attended the courses. The purpose of this third edition of the lecture notes is to bring the latest techniques in microwave measurements to this wider audience. The book begins with a survey of the theory of current microwave circuits and continues with a description of the techniques for the measureme

  4. SAFETY MEASURES

    CERN Multimedia

    Relations with the Host States Service; Tel. 75152

    2001-01-01

    Following the recent terrorist attacks, the French authorities have introduced increased-vigilance measures («Vigipirate renforcé») as part of their prevention of terrorism campaign and have expressed the wish to extend these measures to the French part of the CERN site. The Organization has acceded to this request with the understanding that its international status will be respectd and has granted the French Gendarmerie right of access to the Prévessin site and to the LEP/LHC sites on French territory.

  5. Measuring anhedonia

    DEFF Research Database (Denmark)

    Rømer Thomsen, Kristine

    2015-01-01

    about pleasure, which is often, but not always accessible to conscious awareness." (Rømer Thomsen et al., 2015). This framework is in line with Treadway and Zald's (2011) proposal to differentiate between motivational and consummatory types of anhedonia, and stresses the need to combine traditional self......-report measures with behavioral measures or procedures. In time, this approach may lead to improved clinical assessment and treatment. In line with our reconceptualization, increasing evidence suggests that reward processing deficits are not restricted to impaired hedonic impact in major psychiatric disorders...

  6. Measuring Globalization

    OpenAIRE

    Andersen, Torben M.; Herbertsson, Tryggvi Thor

    2003-01-01

    The multivariate technique of factor analysis is used to combine several indicators of economic integration and international transactions into a single measure or index of globalization. The index is an alternative to the simple measure of openness based on trade, and it produces a ranking of countries over time for 23 OECD countries. Ireland is ranked as the most globalized country during the 1990?s, while the UK was at the top during the 1980?s. Some of the most notable changes in the rank...

  7. Radioactivity measurement

    International Nuclear Information System (INIS)

    Bohme, R.F.; Lazerson, M.M.

    1984-01-01

    A problem with ore sorting arrangements is that radiation is difficult to measure accurately while particles are moving at speed past the detector. This is particulary so when dealing with ores such as gold ores which have weak emissions. A method of measuring radioactive emissions from moving radioactive material includes the steps of shielding the radiation detector(s) so that the angle of acceptance of the receptor surface is restricted, and further shielding the shielded portion of the detector with a second material which is less radiation emissive than the material of the first shield. This second shield is between the first shield and the detector

  8. AMS measurements

    International Nuclear Information System (INIS)

    Lawson, E.M.

    1999-01-01

    Accelerator mass spectrometry (AMS) ia an ultrasensitive analysis technique using a system based on a nuclear particle accelerator and its beam transport system to detect and measure individual 14 C ions.. In AMS a 14 C abundance is obtained by comparing the measurement rates of 14 C and 13 C ions. This is not as simple as it sounds. The enormous difference in the numbers of the two isotopes makes it very hard to uniquely detect 14 C ions. For modern samples, those with the most 14 C, some 10 10 13 C ions leave the source for every 14 C ion. However, the use of an accelerator and various high energy techniques makes it possible to the detect the 14 C and to reject the 13 C. in order to achieve this high rejection efficiency the injection magnet is set to transmit only one isotope, namely 14 C. However, a subsequent measurement of 13 C must be made. The number and the rate of arrival of 13 C ions is such that individual ions cannot be measured, instead a 13 C current is measured in a Faraday cup. It is possible to alternate the injection magnet field between that to transmit 14 C and that to transmit 13 C. This method is known as slow cycling but suffers from significant dead (not useful) periods while the magnet field is changed and stabilises. Furthermore and more significantly, during this dead time changes in ion source output may occur distorting the 14 C/ 13 C ratio. We instead employ a method known as fast cycling which involves rapidly increasing the energy of the 13 C ions as they enter the injection magnet. This is achieved by the use of a high voltage (6.7 kV) pulser. We can also inject 12 C by this method although a 14.7 kV pulse is required. The switching time from one carbon isotope to another is only a fraction of a millisecond in this fast cycling method. Hence one has quasi-simultaneous measurement of 14 C and 13 C. Measurements of the 14 C/ 13 C ratio from a sample are always compared to the same ratio from an internationally accepted standard

  9. Air pollution and environmental risk factors for altered lung function among adult women of an urban slum area of Delhi: A prevalence study.

    Science.gov (United States)

    Arora, Shweta; Rasania, S K; Bachani, D; Gandhi, Asha; Chhabra, S K

    2018-01-01

    Household and ambient air pollution are jointly responsible for about 7 million premature deaths annually. Women living in slums, with unhealthy environment, both indoors and outdoors, particularly those living close to industrial and/or vehicular pollution zones due to multiple sources of air pollution, are at the higher risk of having impaired lung function tests. The aim of this study was to estimate the prevalence of abnormal lung functions and to identify the environmental risk factors associated with them among adult women of 18-59 years. A total of 550 women aged 18-59 years were approached in a representative urban slum. Five hundred consented to participate and 299 had prebronchodilator spirometry satisfying ATS standards. House visits to assess environmental conditions were conducted to determine their association with forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC). Chi-square test was used to test the association of risk factors with lung functions. ANOVA was used to test the association of mean values of FEV1 and FVC with age. Out of 299 participants with acceptable spirometric curves, 5% had reduced FEV1/FVC ratio than the normal and 26.8% and 17.4% had lower values than predicted for FVC and FEV1, respectively. Altered lung function was related to age, tobacco smoking, and history of respiratory disease. Both ambient and household air pollution have a deleterious pulmonary effect on long-term women residents of a representative urban slum in Delhi.

  10. Measuring Trust

    OpenAIRE

    Glaeser, Edward Ludwig; Laibson, David I.; Scheinkman, Jose A.; Soutter, Christine L.

    2000-01-01

    We combine two experiments and a survey to measure trust and trustworthiness—two key components of social capital. Standard attitudinal survey questions about trust predict trustworthy behavior in our experiments much better than they predict trusting behavior. Trusting behavior in the experiments is predicted by past trusting behavior outside of the experiments. When individuals are closer socially, both trust and trustworthiness rise. Trustworthiness declines when partners are of differen...

  11. Radiation measurement

    International Nuclear Information System (INIS)

    Go, Sung Jin; Kim, Seung Guk; No, Gyeong Seok; Park, Myeong Hwan; Ann, Bong Seon

    1998-03-01

    This book explains technical terms about radiation measurement, which are radiation, radiation quantity and unit such as prefix of international unit, unit for defence purposes of radiation, coefficient of radiation and interaction, kinds and principles of radiation detector, ionization chamber, G-M counter, G-M tube, proportional counter, scintillation detector, semiconductor radiation detector, thermoluminescence dosimeter, PLD, others detector, radiation monitor, neutron detector, calibration of radiation detector, statistics of counting value, activation analysis and electronics circuit of radiation detector.

  12. Measuring phase with Stokes measurements

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2014-07-01

    Full Text Available Measurements Angela Dudley1, Giovanni Milione2, Robert Alfano2 and Andrew Forbes1. 1 CSIR National Laser Centre, Pretoria, South Africa. 2 Institute for Ultrafast Spectroscopy and Lasers, Physics Department, City College of New York,160 Convent Ave., New...

  13. Chest wall stabilization and reconstruction: short and long-term results 5 years after the introduction of a new titanium plates system.

    Science.gov (United States)

    De Palma, Angela; Sollitto, Francesco; Loizzi, Domenico; Di Gennaro, Francesco; Scarascia, Daniele; Carlucci, Annalisa; Giudice, Giuseppe; Armenio, Andrea; Ludovico, Rossana; Loizzi, Michele

    2016-03-01

    We report short and long-term results with the dedicated Synthes(®) titanium plates system, introduced 5 years ago, for chest wall stabilization and reconstruction. We retrospectively analyzed (January 2010 to December 2014) 27 consecutive patients (22 males, 5 females; range 16-83 years, median age 60 years), treated with this system: primary [3] and secondary [8] chest wall tumor; flail chest [5]; multiple ribs fractures [5]; sternal dehiscence-diastasis [3]; sternal fracture [1]; sternoclavicular joint dislocation [1]; Poland syndrome [1]. Short-term results were evaluated as: operating time, post-operative morbidity, mortality, hospital stay; long-term results as: survival, plates-related morbidity, spirometric values, chest pain [measured with Verbal Rating Scale (VRS) and SF12 standard V1 questionnaire]. Each patient received from 1 to 10 (median 2) titanium plates/splints; median operating time was 150 min (range: 115-430 min). Post-operative course: 15 patients (55.6%) uneventful, 10 (37%) minor complications, 2 (7.4%) major complications; no post-operative mortality. Median post-operative hospital stay was 13 days (range: 5-129 days). At a median follow-up of 20 months (range: 1-59 months), 21 patients (78%) were alive, 6 (22%) died. Three patients presented long-term plates-related morbidity: plates rupture [2], pin plate dislodgment [1]; two required a second surgical look. One-year from surgery median spirometric values were: FVC 3.31 L (90%), FEV1 2.46 L (78%), DLCO 20.9 mL/mmHg/min (76%). On 21 alive patients, 7 (33.3%) reported no pain (VRS score 0), 10 (47.6%) mild (score 2), 4 (19.1%) moderate (score 4), no-one severe (score >4); 15 (71.5%) reported none or mild, 6 (28.5%) moderate pain influencing quality of life. An optimal chest wall stabilization and reconstruction was achieved with the Synthes(®) titanium plates system, with minimal morbidity, no post-operative mortality, acceptable operating time and post-operative hospital stay. Long

  14. A new approach to assess COPD by identifying lung function break-points

    Directory of Open Access Journals (Sweden)

    Eriksson G

    2015-10-01

    Full Text Available Göran Eriksson,1,* Linnea Jarenbäck,1,* Stefan Peterson,2 Jaro Ankerst,1 Leif Bjermer,1 Ellen Tufvesson11Respiratory Medicine and Allergology, Department of Clinical Sciences, Lund University, 2Regional Cancer Center South, Skåne University Hospital, Lund, Sweden*These authors contributed equally to this workPurpose: COPD is a progressive disease, which can take different routes, leading to great heterogeneity. The aim of the post-hoc analysis reported here was to perform continuous analyses of advanced lung function measurements, using linear and nonlinear regressions.Patients and methods: Fifty-one COPD patients with mild to very severe disease (Global Initiative for Chronic Obstructive Lung Disease [GOLD] Stages I–IV and 41 healthy smokers were investigated post-bronchodilation by flow-volume spirometry, body plethysmography, diffusion capacity testing, and impulse oscillometry. The relationship between COPD severity, based on forced expiratory volume in 1 second (FEV1, and different lung function parameters was analyzed by flexible nonparametric method, linear regression, and segmented linear regression with break-points.Results: Most lung function parameters were nonlinear in relation to spirometric severity. Parameters related to volume (residual volume, functional residual capacity, total lung capacity, diffusion capacity [diffusion capacity of the lung for carbon monoxide], diffusion capacity of the lung for carbon monoxide/alveolar volume and reactance (reactance area and reactance at 5Hz were segmented with break-points at 60%–70% of FEV1. FEV1/forced vital capacity (FVC and resonance frequency had break-points around 80% of FEV1, while many resistance parameters had break-points below 40%. The slopes in percent predicted differed; resistance at 5 Hz minus resistance at 20 Hz had a linear slope change of -5.3 per unit FEV1, while residual volume had no slope change above and -3.3 change per unit FEV1 below its break-point of 61

  15. Measuring circuits

    CERN Document Server

    Graf, Rudolf F

    1996-01-01

    This series of circuits provides designers with a quick source for measuring circuits. Why waste time paging through huge encyclopedias when you can choose the topic you need and select any of the specialized circuits sorted by application?This book in the series has 250-300 practical, ready-to-use circuit designs, with schematics and brief explanations of circuit operation. The original source for each circuit is listed in an appendix, making it easy to obtain additional information.Ready-to-use circuits.Grouped by application for easy look-up.Circuit source listings

  16. Measuring progress

    DEFF Research Database (Denmark)

    Wahlberg, Ayo

    2007-01-01

    In recent years, sociological examinations of genetics, therapeutic cloning, neuroscience and tissue engineering have suggested that 'life itself' is currently being transformed through technique with profound implications for the ways in which we understand and govern ourselves and others...... in much the same way that mortality rates, life expectancy or morbidity rates can. By analysing the concrete ways in which human progress has been globally measured and taxonomised in the past two centuries or so, I will show how global stratifications of countries according to their states...

  17. Nuclear measurements

    International Nuclear Information System (INIS)

    Schenkel, R.

    2005-01-01

    Nuclear measurements play a fundamental role in the development of nuclear technology and the assurance of its peaceful use. They are also required in many non-power nuclear applications such as in nuclear medicine, agriculture, environmental protection, etc. This presentation will show examples of most recent advances in measurement methodology or technology in the areas described below. The Generation IV International Forum has selected six innovative reactor systems as candidates for a next generation of sustainable, economic and safe nuclear energy systems. The choice of the best options relies heavily on the availability of accurate nuclear data that can only be obtained, in an international effort, using highly specialised facilities. Significant efforts are being directed towards the partitioning and transmutation of highly active nuclear waste. Different concepts involving fast reactors or accelerator-driven systems are being studied in view of their transmutation capabilities. State of the art equipment has been developed to assess basic properties of nuclear fuel at very high burn-up; some fine examples of this work will be shown. Physical and chemical methods play a crucial role in the detection and identification of radioisotopes used in various stages of the nuclear fuel cycle. Radiation measurement techniques are used, for example, to monitor the quantities of uranium, plutonium and other actinide elements in fuel enrichment and reprocessing facilities. Another field of application of physical and chemical methods is the characterisation of nuclear material seized from illicit trafficking. Seized material has to be analysed in order to obtain clues on its origin and intended use and to prevent diversion of nuclear material from the same source in the future. A recent highlight in basic physics relates to nuclear fission and transmutation with high intensity lasers. Ultra-fast high intensity lasers can produce high energy (tens of MeV) photons through

  18. BMI, waist circumference at 8 and 12 years of age and FVC and FEV1 at 12 years of age; the PIAMA birth cohort study

    NARCIS (Netherlands)

    Bekkers, Marga B; Wijga, Alet H; Gehring, Ulrike; Koppelman, Gerard H; de Jongste, Johan C; Smit, Henriette A; Brunekreef, Bert

    2015-01-01

    BACKGROUND: In adults, overweight is associated with reduced lung function, in children evidence on this association is conflicting. We examined the association of body mass index (BMI) and waist circumference (WC) at age 12, and of persistently (at ages 8 and 12 years) high BMI and large WC, with

  19. Measuring Quality

    DEFF Research Database (Denmark)

    Næsby, Torben

    local differences in the quality of day care facilities in Denmark (Nordahl et al, 2012; Hansen et al, 2016) and also that we in fact have little knowledge of whether the desired politically determined targets are being met or not and what the quality is really like. In order to measure the quality......The Danish Day Care Facilities Act (2015), which provides the curriculum on which day care education is based, does not stipulate very clearly what children should learn and therefore how educational processes in preschools should be organised. This means that we must accept that there are large...... of preschool in Denmark a new research project using the ECERS 3 instrument has been launched. This could capture quality from a global quality standard’s perspective, building the basis for a further investigation of practice in Danish early childhood provisions and centers in a more narrow approach...

  20. The role of endotoxin in grain dust-induced lung disease.

    Science.gov (United States)

    Schwartz, D A; Thorne, P S; Yagla, S J; Burmeister, L F; Olenchock, S A; Watt, J L; Quinn, T J

    1995-08-01

    To identify the role of endotoxin in grain dust-induced lung disease, we conducted a population-based, cross-sectional investigation among grain handlers and postal workers. The study subjects were selected by randomly sampling all grain facilities and post offices within 100 miles of Iowa City. Our study population consisted of 410 grain workers and 201 postal workers. Grain workers were found to be exposed to higher concentrations of airborne dust (p = 0.0001) and endotoxin (p = 0.0001) when compared with postal workers. Grain workers had a significantly higher prevalence of work-related (cough, phlegm, wheezing, chest tightness, and dyspnea) and chronic (usual cough or phlegm production) respiratory symptoms than postal workers. Moreover, after controlling for age, gender, and cigarette smoking status, work-related respiratory symptoms were strongly associated with the concentration of endotoxin in the bioaerosol in the work setting. The concentration of total dust in the bioaerosol was marginally related to these respiratory problems. After controlling for age, gender, and cigarette smoking status, grain workers were found to have reduced spirometric measures of airflow (FEV1, FEV1/FVC, and FEF25-75) and enhanced airway reactivity to inhaled histamine when compared with postal workers. Although the total dust concentration in the work environment appeared to have little effect on these measures of airflow obstruction, higher concentrations of endotoxin in the bioaerosol were associated with diminished measures of airflow and enhanced bronchial reactivity. Our results indicate that the concentration of endotoxin in the bioaerosol may be particularly important in the development of grain dust-induced lung disease.

  1. Changes in pulmonary function after definitive radiotherapy for NSCLC

    DEFF Research Database (Denmark)

    Schytte, Tine; Bentzen, Søren M; Brink, Carsten

    2015-01-01

    a negative impact on FVC. Long-term FEV1 and FVC were analyzed using linear regression. Treatment year and V60 had a significant impact on loss of FEV1. V60 had a significant impact on FVC changes. CONCLUSION: In this study, early PF change reached a plateau at 6months after the start of radiotherapy......INTRODUCTION: The objective of this study was to identify factors associated with early and long-term pulmonary function (PF) changes after definitive radiotherapy for NSCLC patients. PF was measured by spirometry i.e. forced expiratory volume in 1s (FEV1), and forced vital capacity (FVC...

  2. Computational fluid dynamics in the assessment of patients' postoperative status after glottis-widening surgery.

    Science.gov (United States)

    Marków, Magdalena; Janecki, Daniel; Orecka, Bogusława; Misiołek, Maciej; Warmuziński, Krzysztof

    2017-09-01

    Computational fluid dynamics (CFD), a rapidly developing instrument with a number of practical applications, allows calculation and visualization of the changing parameters of airflow in the upper respiratory tract. The aim of this study was to demonstrate the advantages of CFD as an instrument for noninvasive tests of the larynx in patients who had undergone surgical treatment due to bilateral vocal fold paralysis. Surface measurements of the glottic space were made during maximum adduction of the vocal folds. Additionally, the following spirometric parameters were determined: forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), and peak expiratory flow (PEF) rate. Based on the measurements, commercial mesh generation software was used to develop a geometrical model of the glottic space. The computations were carried out using a general purpose CFD code. The analysis included patients who were surgically treated for BVFP in the authors' department between 1999 and 2012. The study group consisted of 22 women (91.67%) and 2 men (8.33%). It was observed that the pressure drop calculated for free breathing depends on the area of the glottis and is independent of its shape. Importantly, for areas below approx. 40 mm2, a sudden rise occurred in the resistance to flow; for the smallest glottic areas studied, the pressure drop was almost 6 times higher than for an area of 40 mm2. Consequently, in cases of areas below 40 mm2 even minor enlargement of the glottic opening can lead to a marked improvement in breathing comfort. Computational fluid dynamics is a useful method for calculating and visualizing the changing parameters of airflow in the upper respiratory tract.

  3. Comparison and Validation of Long Time Serial Global GEOV1 and Regional Australian MODIS Fractional Vegetation Cover Products Over the Australian Continent

    Directory of Open Access Journals (Sweden)

    Yanling Ding

    2015-05-01

    Full Text Available Fractional vegetation cover (FVC is one of the most critical parameters in monitoring vegetation status. Comprehensive assessment of the FVC products is critical for their improvement and use in land surface models. This study investigates the performances of two major long time serial FVC products: GEOV1 and Australian MODIS. The spatial and temporal consistencies of these products were compared during the 2000–2012 period over the main biome types across the Australian continent. Their accuracies were validated by 443 FVC in-situ measurements during the 2011–2012 period. Our results show that there are strong correlations between the GEOV1 and Australian MODIS FVC products over the main Australian continent while they exhibit large differences and uncertainties in the coastal regions covered by dense forests. GEOV1 and Australian MODIS describe similar seasonal variations over the main biome types with differences in magnitude, while Australian MODIS exhibit unstable temporal variations over grasslands and shifted seasonal variations over evergreen broadleaf forests. The GEOV1 and Australian MODIS products overestimate FVC values over the biome types with high vegetation density and underestimate FVC in sparsely vegetated areas and grasslands. Overall, the GEOV1 and Australian MODIS FVC products agree with in-situ FVC values with a RMSE around 0.10 over the Australian continent.

  4. The impact of different spirometric definitions on the prevalence of airway obstruction and their association with respiratory symptoms

    DEFF Research Database (Denmark)

    Meteran, Howraman; Miller, Martin R; Thomsen, Simon Francis

    2017-01-01

    The fixed ratio criterion of forced expiratory volume in 1 s/forced vital capacity <0.70 for diagnosing airway obstruction may overdiagnose the condition, particularly in the elderly, so the lower limit of normal (LLN) is recommended as the most appropriate criterion. Our aim was to compare LLN v...

  5. Impact of air quality in Kuala Lumpur on human lung function

    International Nuclear Information System (INIS)

    Noor, H.; Mohammad, F.; Othman, Z.; Rashid, N.; Johan, R.; Awang, M.; Jaafar, Abu-Bakar

    1998-01-01

    In Malaysia, the 1997 haze was the worst air pollution episode ever experienced by the country. The polluted air consists of various of various gases and aerosols including nitrogen dioxide and particulate matter (PM/sub 10/). A spirometry study on lung function of traffic policemen (n=45) in KL showed a correlation between lung volumes and the concentration of NO/sub 2/ they were directly exposed to (0.014 ppm) The controls were UPM students and staff (n=23, non-smokers) of the same age group exposed to 0.005 ppm. There were significant reductions (unpaired t-test, p<0.05) in FVC compared to control (2.84++0.12 vs. e. 21+-0.16), FEV (2.54+-0.12 vs 3.04+-0.13), FEV/sub 1/ % (84.14+-2.09 vs 92.02+-1.36) and FEF/sub 25-75 %/ (3.23+-0.26 vs 4.50 +0.35), indicative of obstructions that may occur in both the large and smaller airways. In addition, higher percentage of respiratory symptoms were reported in the study subjects, the highest was continuous coughs (32% vs. 9%). Another study was done on school children in KL and Negri Sembilan, who were exposed to PM/sub 10/ of 103.27 mu g/m/sup 3/ and 47.35 mu g /m/sup 3/ respectively. Spirometric measurements show significant reductions in VC and FVC for boys compared to control (32% vs 3.25+-0.43 and 2.64+-0.48 v 2.94+-0.52, respectively) indicating signs of airways obstruction and lung restriction. Respiratory symptoms were also higher in the study subjects. The highest is chest tightness (63.18% in female, 35.19% in male) and breathing difficulties (53.05%) and 22.08% respectively) compared to controls. Conclusion made from the two studies was; exposure to 0.014 ppm of NO/sub 2/ and 103.27 mu g/m-3 of PM/sub 10/ correlates with reduced human lung function and increased respiratory symptoms due to obstruction of airways and restriction of the lung. (author)

  6. Influência da adequação postural em cadeira de rodas na função respiratória de pacientes com amiotrofia espinhal tipo II Influence of wheelchair positioning aids on the respiratory function of patients with type II spinal muscular atrophy

    Directory of Open Access Journals (Sweden)

    Luanda André Collange

    2009-09-01

    Full Text Available Este estudo visou determinar a influência da adequação postural em cadeira de rodas na função respiratória de pacientes com amiotrofia espinhal tipo II (AME. Doze pacientes (idades entre 7 e 24 anos com diagnóstico de AME II, confirmado por achados clínicos e análise genética, participaram do estudo. Os parâmetros respiratórios - volume minuto (VM, volume corrente (VC, capacidade vital forçada (CVF, pressões inspiratória (PImáx e expiratória (PEmáx máximas e pico de fluxo expiratório (PFE - na cadeira de rodas individual, com adaptações, e em uma cadeira de rodas padrão, isto é, sem reclinação ou inclinação. Os resultados mostram valores melhores estatisticamente significativos de todos os parâmetros respiratórios (VM, p=0,002; VC, p=0,003; CVF, p=0,017; PImáx, p=0,002; PEmáx, p=0,006; e PFE, p=0,007 nas medidas tomadas na cadeira adaptada para a postura adequada. Os resultados permitem concluir que a adequação postural em cadeira de rodas influencia positivamente a função respiratória de pacientes com AME tipo II.This study aimed at determining the influence of adequate wheelchair positioning aids on the respiratory function in spinal muscular atrophy (SMA type II patients. Twelve patients (aged 7 to 24 with SMA diagnosed by clinical findings and confirmed by genetic analysis, who owned wheelchairs with positioning aids, underwent spirometric assessment - as to minute volume (MV, tidal volume (TV, forced vital capacity (FVC, maximum inspiratory (IPmax and expiratory (EPmax pressures, and peak expiratory flow (PEF - both on their own wheelchair and on a standard wheelchair with no recline or tilt. Results show significantly better values in all assessed parameters (MV, p=0.002; TV, p=0.003; FVC, p=0.017; IPmax, p=0.002, EPmax, p=0.006; and PEF, p=0.007 of measures taken at the patient's own chair, with positioning aids. These results allow for concluding that wheelchair positioning aids may positively

  7. Electricity electron measurement

    International Nuclear Information System (INIS)

    Kim, Sang Jin; Sung, Rak Jin

    1985-11-01

    This book deals with measurement of electricity and electron. It is divided into fourteen chapters, which depicts basic of electricity measurement, unit and standard, important electron circuit for measurement, instrument of electricity, impedance measurement, power and power amount measurement, frequency and time measurement, waveform measurement, record instrument and direct viewing instrument, super high frequency measurement, digital measurement on analog-digital convert, magnetic measurement on classification by principle of measurement, measurement of electricity application with principle sensors and systematization of measurement.

  8. The newest precision measurement

    International Nuclear Information System (INIS)

    Lee, Jing Gu; Lee, Jong Dae

    1974-05-01

    This book introduces basic of precision measurement, measurement of length, limit gauge, measurement of angles, measurement of surface roughness, measurement of shapes and locations, measurement of outline, measurement of external and internal thread, gear testing, accuracy inspection of machine tools, three dimension coordinate measuring machine, digitalisation of precision measurement, automation of precision measurement, measurement of cutting tools, measurement using laser, and point of choosing length measuring instrument.

  9. Spirometry Reference Equations from the HCHS/SOL (Hispanic Community Health Study/Study of Latinos).

    Science.gov (United States)

    LaVange, Lisa; Davis, Sonia M; Hankinson, John; Enright, Paul; Wilson, Rebbecca; Barr, R Graham; Aldrich, Thomas K; Kalhan, Ravi; Lemus, Hector; Ni, Ai; Smith, Lewis J; Talavera, Gregory A

    2017-10-15

    Accurate reference values for spirometry are important because the results are used for diagnosing common chronic lung diseases such as asthma and chronic obstructive pulmonary disease, estimating physiologic impairment, and predicting all-cause mortality. Reference equations have been established for Mexican Americans but not for others with Hispanic/Latino backgrounds. To develop spirometry reference equations for adult Hispanic/Latino background groups in the United States. The HCHS/SOL (Hispanic Community Health Study/Study of Latinos) recruited a population-based probability sample of 16,415 Hispanics/Latinos aged 18-74 years living in the Bronx, Chicago, Miami, and San Diego. Participants self-identified as being of Puerto Rican, Cuban, Dominican, Mexican, or Central or South American background. Spirometry was performed using standardized methods with central quality control monitoring. Spirometric measures from a subset of 6,425 never-smoking participants without respiratory symptoms or disease were modeled as a function of sex, age, height, and Hispanic/Latino background to produce background-specific reference equations for the predicted value and lower limit of normal. Dominican and Puerto Rican Americans had substantially lower predicted and lower limit of normal values for FVC and FEV 1 than those in other Hispanic/Latino background groups and also than Mexican American values from NHANES III (Third National Health and Nutrition Examination Survey). For patients of Dominican and Puerto Rican background who present with pulmonary symptoms in clinical practice, use of background-specific spirometry reference equations may provide more appropriate predicted and lower limit of normal values, enabling more accurate diagnoses of abnormality and physiologic impairment.

  10. Six minute walk test in respiratory diseases: A university hospital experience

    Directory of Open Access Journals (Sweden)

    Al Ameri Hatem

    2006-01-01

    Full Text Available BACKGROUND: Six minutes walk test (6MWT, is a sub-maximal exercise test, used as a clinical indicator of the functional capacity, in patients with cardiopulmonary diseases. Its safety, validity, reliability and its correlation with several physiological instruments, are well studied. However, there are no published data on 6MWT, in the Saudi population. We are reviewing our experience with 6MWT and assessing its safety and its correlation with pulmonary function variables, in patients with pulmonary diseases, in our local population. MATERIALS AND METHODS: We consecutively studied patients with pulmonary diseases, who underwent 6MWT and pulmonary function test in King Khalid University Hospital, from June 2003 to December 2004. The 6MWTs were conducted according to the American Thoracic Society guidelines. Spirometry, lung volumes and diffusion capacity measurements were correlated with the absolute walked distance. RESULTS: One hundred and twenty nine tests were performed. All patients were of the Saudi community (59% female, with mean age of 43±15 years. Out of 129 patients, 65 patients had proven respiratory diagnosis. In all patients, the test were performed with no serious complications. The six minute walk distance (6MWD had correlation with patient′s height (r=+0.40, P < 0.001, but not with patients′ weight, BMI, borg scale, or oxygen saturation. The 6MWD correlated significantly with Dlco (r=+0.52, P < 0.01, FVC (r=+0.46, r< 0.001 and had a weaker relation with FEV1 (r=+0.31, P < 0.05. The test had no significant correlation with lung volumetric parameters (TLC, FRC and RV. CONCLUSION: 6MWT is simple and safe test in evaluating patients with chronic pulmonary diseases in the Saudi population. In our study, 6MWD showed correlation with spirometric parameters and diffusion capacity. Further studies are needed to evaluate 6MWT in a more homogenous patients′ population.

  11. Cross sectional analysis of respiratory symptoms in an injection drug user cohort: the impact of obstructive lung disease and HIV

    Directory of Open Access Journals (Sweden)

    Mehta Shruti H

    2010-05-01

    Full Text Available Abstract Background Injection drug use is associated with an increased risk of human immunodeficiency virus (HIV infection and with obstructive lung diseases (OLD. Understanding how HIV and OLD may impact respiratory symptoms among injection drug users (IDUs is important to adequately care for this high-risk population. We characterized the independent and joint effects of HIV and OLD on respiratory symptoms of a cohort of inner-city IDUs. Methods Demographics, risk behavior and spirometric measurements were collected from a cross-sectional analysis of the Acquired Immunodeficiency Syndrome Link to the IntraVenous Experience study, an observational cohort of IDUs followed in Baltimore, MD since 1988. Participants completed a modified American Thoracic Society respiratory questionnaire and the Medical Research Council (MRC dyspnea score to assess respiratory symptoms of cough, phlegm, wheezing and dyspnea. Results Of 974 participants, 835 (86% were current smokers and 288 (29.6% were HIV-infected. The prevalence of OLD (FEV1/FVC ≤ 0.70 was 15.5%, and did not differ by HIV status. OLD, but not HIV, was associated with increased frequency of reported respiratory symptoms. There was a combined effect of OLD and HIV on worsening of MRC scores. OLD and HIV were independently associated with an increased odds of reporting an MRC ≥ 2 (OR 1.83 [95%CI 1.23-2.73] and 1.50 [95%CI 1.08-2.09], respectively. COPD, but not HIV, was independently associated with reporting an MRC ≥ 3 (OR 2.25 [95%CI 1.43-3.54] and 1.29 [95%CI 0.87-1.91], respectively. Conclusions While HIV does not worsen cough, phlegm or wheezing, HIV significantly increases moderate but not severe dyspnea in individuals of similar OLD status. Incorporating the MRC score into routine evaluation of IDUs at risk for OLD and HIV provides better assessment than cough, phlegm and wheezing alone.

  12. Exposure to occupational dust and changes in pulmonary function among cobblestone paving workers of Jimma, Ethiopia

    Directory of Open Access Journals (Sweden)

    Kalkidan Abate Hassen

    2014-01-01

    Full Text Available The classic diseases of "dusty" occupations may be on decline, but they are not yet extinct. Studies have found associations between changes in ambient particulate air pollution and increased cardiorespiratory morbidity and mortality. A cross-sectional comparative study design was employed on 127 male nonsmoker cobblestone paving workers and 194 matched employed office workers as a reference in order to assess changes in pulmonary function related to dust exposure among cobblestone road paving workers of Jimma zone, Ethiopia. Data was collected using structured questionnaires and spirometric measurements after ethical clearance was obtained. Data was analyzed using unpaired t-tests to examine the differences between the groups. P-values equal or less than 0.05 were considered statistically significant; odds were calculated at a 95% confidence interval. Cobblestone road paving workers had significantly higher odds of respiratory symptoms, dry cough (p < 0.05, cough (p < 0.01 and sore throat (p< 0.001 compared to the reference. The FEV1 for workers exposed to cobblestone road paving workers ranged between 3.12 - 4.73 L, with a mean of 3.96 ± 0.6 L, significantly lower than the reference groups who had a range of 3.3 - 4.78 L and a mean of 4.01 ± 0.6 L (p < 0.05. The mean value of the ratio of FEV1/FVC was significantly decreased in the cobblestone road paving workers compared to the controls (87.2 (SD 4.3 v 89.5 (SD 5.4, p = 0.01. In conclusion, the study revealed clear evidence of the need for health education and for the promotion of activities directed towards mitigating respiratory hazards in order to foster a safe and healthy work environment.

  13. Practical precision measurement

    International Nuclear Information System (INIS)

    Kwak, Ho Chan; Lee, Hui Jun

    1999-01-01

    This book introduces basic knowledge of precision measurement, measurement of length, precision measurement of minor diameter, measurement of angles, measurement of surface roughness, three dimensional measurement, measurement of locations and shapes, measurement of screw, gear testing, cutting tools testing, rolling bearing testing, and measurement of digitalisation. It covers height gauge, how to test surface roughness, measurement of plan and straightness, external and internal thread testing, gear tooth measurement, milling cutter, tab, rotation precision measurement, and optical transducer.

  14. Dietary Intake of Flavonoids and Ventilatory Function in European Adults: A GA2LEN Study

    Directory of Open Access Journals (Sweden)

    Vanessa Garcia-Larsen

    2018-01-01

    Full Text Available Background: Flavonoids exert anti-inflammatory properties and modulate oxidative stress in vitro, suggesting a protective effect on lung function, but epidemiological studies examining this association are scarce. Methods: A stratified random sample was drawn from the GA2LEN screening survey, in which 55,000 adults aged 15 to 75 answered a questionnaire on respiratory symptoms. Post-bronchodilator spirometry was obtained from 2850 subjects. Forced vital capacity (FVC, the ratio between the forced exhaled volume in 1 second (FEV1 and FVC (FEV1/FVC, FVC below lower limit of normal (FVC < LLN, and FEV1/FVC < LLN were calculated. Intake of the six main subclasses of flavonoids was estimated using the GA2LEN Food Frequency Questionnaire. Adjusted associations between outcomes and each subclass of flavonoids were examined with multivariate regressions. Simes’ procedure was used to test for multiple comparisons. Results: A total of 2599 subjects had valid lung function and dietary data. A lower prevalence of FVC < LLN (airway restriction was observed in those with higher total flavonoid (adjusted odds ratio (aOR, higher vs. lowest quintile intake 0.58; 95% Confidence Interval (CI 0.36, 0.94, and pro-anthocyanidin intakes (aOR 0.47; 95% CI 0.27, 0.81. A higher FEV1/FVC was associated with higher intakes of total flavonoids and pro-anthocyanidins (adjusted correlation coefficient (a β-coeff 0.33; 0.10, 0.57 and a β-coeff 0.44; 95% CI 0.19, 0.69, respectively. After Simes’ procedure, the statistical significance of each of these associations was attenuated but remained below 0.05, with the exception of total flavonoids and airway restriction. Conclusions: This population-based study in European adults provides cross-sectional evidence of a positive association of total flavonoid intake and pro-anthocyanidins and ventilatory function, and a negative association with spirometric restriction in European adults.

  15. Can Serum Surfactant Protein D or CC-Chemokine Ligand 18 Predict Outcome of Interstitial Lung Disease in Patients with Early Systemic Sclerosis?

    Science.gov (United States)

    Elhaj, Mona; Charles, Julio; Pedroza, Claudia; Liu, Xiaochun; Zhou, Xiaodong; Estrada-Y-Martin, Rosa M.; Gonzalez, Emilio B.; Lewis, Dorothy E.; Draeger, Hilda T.; Kim, Sarah; Arnett, Frank C.; Mayes, Maureen D.; Assassi, Shervin

    2013-01-01

    Objective To examine the predictive significance of 2 pneumoproteins, surfactant protein D (SP-D) and CC-chemokine ligand 18 (CCL18), for the course of systemic sclerosis (SSc)-related interstitial lung disease. Methods The pneumoproteins were determined in the baseline plasma samples of 266 patients with early SSc enrolled in the GENISOS observational cohort. They also were measured in 83 followup patient samples. Pulmonary function tests were obtained annually. The primary outcome was decline in forced vital capacity (FVC percentage predicted) over time. The predictive significance for longterm change in FVC was investigated by a joint analysis of longitudinal measurements (sequentially obtained FVC percentage predicted) and survival data. Results SP-D and CCL18 levels were both higher in patients with SSc than in matched controls (p < 0.001 and p = 0.015, respectively). Baseline SP-D levels correlated with lower concomitantly obtained FVC (r = −0.27, p < 0.001), but did not predict the short-term decline in FVC at 1 year followup visit or its longterm decline rate. CCL18 showed a significant correlation with steeper short-term decline in FVC (p = 0.049), but was not a predictor of its longterm decline rate. Similarly, a composite score of SP-D and CCL18 was a significant predictor of short-term decline in FVC but did not predict its longterm decline rate. Further, the longitudinal change in these 2 pneumoproteins did not correlate with the concomitant percentage change in FVC. Conclusion SP-D correlated with concomitantly obtained FVC, while CCL18 was a predictor of short-term decline in FVC. However, neither SP-D nor CCL18 was a longterm predictor of FVC course in patients with early SSc. PMID:23588945

  16. Efeito da obesidade na função ventilatória Impact of obesity on ventilatory function

    Directory of Open Access Journals (Sweden)

    Perran Boran

    2007-04-01

    of excess body weight, with no history of asthma or other atopic diseases were studied and compared to a control group of 50 normal weight children controlled for age and sex. The mean age of patients was 9.7±2.5 years (7 to 15 years. Anthropometric measurements and spirometry were performed in all subjects. Forced vital capacity (FVC and forced expiratory volume in 1 second (FEV1 were used as measures of ventilatory function. RESULTS: There were no significant differences in FEV1%, FVC% and FEV1%/FVC% by study group (p > 0.05. Only three patients had obstructive abnormalities documented on their pulmonary function tests (two had moderately severe and one had mild obstructive abnormalities. No correlation was observed between pulmonary function parameters and anthropometric measurements. CONCLUSION: These data demonstrate that pulmonary function test parameters of the mildly obese children were similar to those of the normal weight children. Anthropometric measurements had no significant effect on spirometric measurements in children as they did on adults.

  17. Measure and dimension functions: measurability and densities

    Science.gov (United States)

    Mattila, Pertti; Mauldin, R. Daniel

    1997-01-01

    During the past several years, new types of geometric measure and dimension have been introduced; the packing measure and dimension, see [Su], [Tr] and [TT1]. These notions are playing an increasingly prevalent role in various aspects of dynamics and measure theory. Packing measure is a sort of dual of Hausdorff measure in that it is defined in terms of packings rather than coverings. However, in contrast to Hausdorff measure, the usual definition of packing measure requires two limiting procedures, first the construction of a premeasure and then a second standard limiting process to obtain the measure. This makes packing measure somewhat delicate to deal with. The question arises as to whether there is some simpler method for defining packing measure and dimension. In this paper, we find a basic limitation on this possibility. We do this by determining the descriptive set-theoretic complexity of the packing functions. Whereas the Hausdorff dimension function on the space of compact sets is Borel measurable, the packing dimension function is not. On the other hand, we show that the packing dimension functions are measurable with respect to the [sigma]-algebra generated by the analytic sets. Thus, the usual sorts of measurability properties used in connection with Hausdorff measure, for example measures of sections and projections, remain true for packing measure.

  18. Vital capacity and COPD: the Swedish CArdioPulmonary bioImage Study (SCAPIS

    Directory of Open Access Journals (Sweden)

    Torén K

    2016-05-01

    Full Text Available Kjell Torén,1 Anna-Carin Olin,1 Anne Lindberg,2 Jenny Vikgren,3 Linus Schiöler,1 John Brandberg,3 Åse Johnsson,3 Gunnar Engström,4 H Lennart Persson,5 Magnus Sköld,6 Jan Hedner,7 Eva Lindberg,8 Andrei Malinovschi,8 Eeva Piitulainen,9 Per Wollmer,9 Annika Rosengren,10 Christer Janson,8 Anders Blomberg,2 Göran Bergström10 1Section of Occupational and Environmental Medicine, Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, 2Department of Public Health and Clinical Medicine, Division of Medicine/Respiratory Medicine, Umeå University, Umeå, 3Department of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, 4Department of Clinical Science, Malmö, Lund University, Lund, 5Department of Respiratory Medicine and Department of Medicine and Health Sciences, Linköping University, Linköping, 6Respiratory Medicine Unit, Department of Medicine Solna, Center for Molecular Medicine, Karolinska Institutet, Stockholm, 7Department of Internal Medicine/Lung Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, 8Department of Medical Sciences, Clinical Physiology and Respiratory, Allergy and Sleep Research, Uppsala University, Uppsala, 9Department of Translational Medicine, Lund University, Malmö, 10Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden Background: Spirometric diagnosis of chronic obstructive pulmonary disease (COPD is based on the ratio of forced expiratory volume in 1 second (FEV1/vital capacity (VC, either as a fixed value <0.7 or below the lower limit of normal (LLN. Forced vital capacity (FVC is a proxy for VC. The first aim was to compare the use of FVC and VC, assessed as the highest value of FVC or slow vital capacity (SVC, when assessing the FEV1/VC ratio in a general population

  19. Influence of Anti-TNF and Disease Modifying Antirheumatic Drugs Therapy on Pulmonary Forced Vital Capacity Associated to Ankylosing Spondylitis: A 2-Year Follow-Up Observational Study

    Directory of Open Access Journals (Sweden)

    Alberto Daniel Rocha-Muñoz

    2015-01-01

    Full Text Available Objective. To evaluate the effect of anti-TNF agents plus synthetic disease modifying antirheumatic drugs (DMARDs versus DMARDs alone for ankylosing spondylitis (AS with reduced pulmonary function vital capacity (FVC%. Methods. In an observational study, we included AS who had FVC% <80% at baseline. Twenty patients were taking DMARDs and 16 received anti-TNF + DMARDs. Outcome measures: changes in FVC%, BASDAI, BASFI, 6-minute walk test (6MWT, Borg scale after 6MWT, and St. George’s Respiratory Questionnaire at 24 months. Results. Both DMARDs and anti-TNF + DMARDs groups had similar baseline values in FVC%. Significant improvement was achieved with anti-TNF + DMARDs in FVC%, at 24 months, when compared to DMARDs alone (P=0.04. Similarly, patients in anti-TNF + DMARDs group had greater improvement in BASDAI, BASFI, Borg scale, and 6MWT when compared to DMARDs alone. After 2 years of follow-up, 14/16 (87.5% in the anti-TNF + DMARDs group achieved the primary outcome: FVC% ≥80%, compared with 11/20 (55% in the DMARDs group (P=0.04. Conclusions. Patients with anti-TNF + DMARDs had a greater improvement in FVC% and cardiopulmonary scales at 24 months compared with DMARDs. This preliminary study supports the fact that anti-TNF agents may offer additional benefits compared to DMARDs in patients with AS who have reduced FVC%.

  20. Pulmonary function in women: comparative analysis of conventional versus single-port laparoscopic cholecystectomy

    Directory of Open Access Journals (Sweden)

    MARISA DE CARVALHO BORGES

    2018-05-01

    Full Text Available ABSTRACT Objective: to evaluate the pulmonary function of women submitted to conventional and single-port laparoscopic cholecystectomy. Methods: forty women with symptomatic cholelithiasis, aged 18 to 70 years, participated in the study. We divided the patients into two groups: 21 patients underwent conventional laparoscopic cholecystectomy, and 19, single-port laparoscopic cholecystectomy. We assessed pulmonary function through forced vital capacity (FVC, forced expiratory volume in the first second (FEV1, and the FEV1/FVC ratio, measured before and 24 hours after the procedure. Results: in both groups, FVC and FEV1 were lower in the postoperative period than those obtained in the preoperative period, with a greater reduction in the group undergoing conventional laparoscopic cholecystectomy. Regarding the FEV1/FVC (% values, there was no statistically significant difference in any of the groups or times analyzed. Conclusion: there was a greater decline in FVC and FEV1 in the postoperative group of patients submitted to conventional laparoscopic cholecystectomy.

  1. Basic pulmonary function tests in pig farmers

    Directory of Open Access Journals (Sweden)

    Đuričić Slaviša M.

    2004-01-01

    absence of important alterations in the basic spirometric measures in this and the majority of the previous studies suggests that early airway injuries may not be readily apparent using spirometric measures of lung function. CONCLUSION In contrast to other world studies, our study comprised an important number of women farmers, but alterations associated to sex were not found. To asses the lung function in these pig farmers after several years may be of great importance.

  2. Comparison of five portable peak flow meters.

    Science.gov (United States)

    Takara, Glaucia Nency; Ruas, Gualberto; Pessoa, Bruna Varanda; Jamami, Luciana Kawakami; Di Lorenzo, Valéria Amorim Pires; Jamami, Mauricio

    2010-05-01

    To compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone, Assess, Galemed, Personal Best and Vitalograph peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (pmeters were 428 (263-688 L/min), 450 (350-800 L/min), 420 (310-720 L/min), 380 (300-735 L/min), 400 (310-685 L/min) and 415 (335-610 L/min), respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone(R) (pmeters. There was no agreement between the spirometric values and the five PEF meters. The results suggest that the values recorded from Galemed meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  3. Lost in interpretation: should the highest VC value be used to calculate the FEV1/VC ratio?

    Directory of Open Access Journals (Sweden)

    Fortis S

    2016-09-01

    Full Text Available Spyridon FortisDepartment of Medicine, Division of Pulmonary, Critical Care and Occupational Medicine, University of Iowa, Iowa City, IA, USAAirflow obstruction or obstructive ventilatory defect (OVD is defined as low forced expiratory volume in 1 second (FEV1 to vital capacity (VC ratio. VC can be measured in various ways, and the definition of “low FEV1/VC” ratio varies.     VC can be measured during forced expiration before bronchodilators (forced vital capacity [FVC] and after bronchodilators (post-FVC, and during slow expiration (slow vital capacity [SVC] and during inspiration (inspiratory vital capacity [IVC]. Theoretically, in a healthy person, VC values should be the same regardless of the maneuver used. Nevertheless, SVC is usually larger than FVC except in patients with no OVD and body mass index <25 kg/m2.1 In obstructive lung diseases, FVC may be reduced, which may result in an increase of FEV1/FVC ratio and misdiagnosis.2 For that reason, American Thoracic Society–European Respiratory Society recommends using SVC or IVC to calculate the FEV1/VC ratio.2 Approximately, 10% of smokers have FEV1% predicted <80% and FEV1/FVC >70%, a pattern known as preserved ratio impaired spirometry.3 Of all the subjects with FVC below the lower limit of normal (LLN and FEV1/FVC > LLN, only 64% have restriction in lung volumes. The rest 36% have a nonspecific Pulmonary Function Test pattern.4 Approximately, 15% of patients with this nonspecific PFT pattern develop OVD in follow-up PFTs.4 It is possible that a portion of patients with obstructive lung disease remain underdiagnosed when FVC is used to compute FEV1/FVC ratio.View the original paper by Torén and colleagues.

  4. Measuring probe for measurement of local velocities

    International Nuclear Information System (INIS)

    Casal, V.; Arnold, G.; Kirchner, R.; Kussmaul, H.; Miller, H.

    1988-03-01

    The report describes a method for measurement of local velocities. It bases on the detection of the propagation of a temperature pulse induced into the fluid. The method can also be applied in flowing liquid metals with superimposed magnetic field; in this case common measuring principles fail application. The measuring system discussed consists of, a measuring head, a heating system, amplifiers and a PC. The latter performs process operation, data sampling, and evaluation of velocity. The measuring head itself includes a miniaturized heater (as a pulse marker) heated by the heating system in a short pulse, and a number of thermocouples (sensors) for detection of signals. The design, construction, and examination of a developed measuring device is described. (orig.) [de

  5. MEASURE FOR MEASURE: A THRICE TOLD TALE

    Directory of Open Access Journals (Sweden)

    HALIMAH MOHAMED ALI

    2009-01-01

    Full Text Available This paper argues that Measure for Measure is a difficult play to perform because it has problematic themes, especially the theme of sexuality, that clash with the way of life and thinking of contemporary society. As such, any director who chooses to stage it must consider these difficulties and how to present them in a natural manner without making the audience feel that the whole production is contrived. The directors of the two major productions discussed in this paper tried their best to present a Measure for Measure that would be acceptable to the modern society. It is evident that there are many interpretations of the Duke and Isabella's characters and also of Isabella's reaction to the Duke's proposal at the end of the play. It can be concluded that no interpretation is wrong because each actor or director brings with him his own reading of the play, and every reading has been influenced by other performances and textual criticisms. Since Measure for Measure is a thematically rich play, it should not be confined to a single interpretation. The different performances of Measure for Measure have proven that theatre is experimental as well as ageless. Because it is a brilliant play with a myriad of interpretations, Measure for Measure will not cease to be a favourite for directors in times to come. It is not wrong to predict that fans of Shakespeare in general and of Measure for Measure in particular can look forward to many more productions.For experienced Shakespeare observers all performances are thrice-told tales. The perceiving eye absorbs the performance even as the mind's eye attends to the text. Both are augmented by the inner ear buzzing with those other voices, both critical and dramatic, carried by the observer into the theatre.(Crowl, Samuel 1992: 3

  6. Measuring transformers in energy measurement technology

    International Nuclear Information System (INIS)

    Vock, E.

    2009-01-01

    This article takes a look at the use of measurement transformers in energy measurement installations in the light of electricity market liberalisation. Such equipment is quoted as being long living and capital-intensive. Increasing requirements on the installation of measurement equipment between partners in a liberalised market are examined. The requirements placed by electricity market legislation on the systems for the various grid voltage levels are discussed. Both current and voltage measurement transformers are looked at and the requirements placed on their accuracy are discussed in detail.

  7. The organizational measurement manual

    National Research Council Canada - National Science Library

    Wealleans, David

    2001-01-01

    ... Relationship of process to strategic measurements Summary 37 36Contents 19/10/2000 1:23 pm Page vi vi THE ORGANIZATIONAL MEASUREMENT MANUAL 4 PART 2 ESTABLISHING A PROCESS MEASUREMENT PROGRAMME...

  8. Measurements on Hearing

    DEFF Research Database (Denmark)

    Poulsen, Torben

    1996-01-01

    Background material for measurements of hearing for grammar school pupils. The note gives the necessary background for the exercise 'Measurement on Hearing'. The topics comprise sound and decibel, the ear, basic psychoacoustics, hearing threshold, audiometric measurement methods, speech and speech...

  9. Software product quality measurement

    OpenAIRE

    Godliauskas, Eimantas

    2016-01-01

    This paper analyses Ruby product quality measures, suggesting three new measures for Ruby product quality measurement tool Rubocop to measure Ruby product quality characteristics defined in ISO 2502n standard series. This paper consists of four main chapters. The first chapter gives a brief view of software product quality and software product quality measurement. The second chapter analyses object oriented quality measures. The third chapter gives a brief view of the most popular Ruby qualit...

  10. Semiconductor Electrical Measurements Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Semiconductor Electrical Measurements Laboratory is a research laboratory which complements the Optical Measurements Laboratory. The laboratory provides for Hall...

  11. Reconsidering formative measurement.

    Science.gov (United States)

    Howell, Roy D; Breivik, Einar; Wilcox, James B

    2007-06-01

    The relationship between observable responses and the latent constructs they are purported to measure has received considerable attention recently, with particular focus on what has become known as formative measurement. This alternative to reflective measurement in the area of theory-testing research is examined in the context of the potential for interpretational confounding and a construct's ability to function as a point variable within a larger model. Although these issues have been addressed in the traditional reflective measurement context, the authors suggest that they are particularly relevant in evaluating formative measurement models. On the basis of this analysis, the authors conclude that formative measurement is not an equally attractive alternative to reflective measurement and that whenever possible, in developing new measures or choosing among alternative existing measures, researchers should opt for reflective measurement. In addition, the authors provide guidelines for researchers dealing with existing formative measures. Copyright 2007 APA, all rights reserved.

  12. Perspectives on Measurement Instruction.

    Science.gov (United States)

    Airasian, Peter W.

    1991-01-01

    This paper seeks to identify ways of making measurement more relevant to classroom teachers, and making classroom realities more apparent to measurement specialists. Measurement elements of teacher education textbooks and courses, nontraditional assessment topics, informal classroom measurement techniques, terminological issues, and three types of…

  13. Can Virtue Be Measured?

    Science.gov (United States)

    Curren, Randall; Kotzee, Ben

    2014-01-01

    This article explores some general considerations bearing on the question of whether virtue can be measured. What is moral virtue? What are measurement and evaluation, and what do they presuppose about the nature of what is measured or evaluated? What are the prospective contexts of, and purposes for, measuring or evaluating virtue, and how would…

  14. Measuring Infant Memory.

    Science.gov (United States)

    Bogartz, Richard S.

    1996-01-01

    Reviews three response rate measures (in a baseline measurement, immediately after acquisition, and at a long-term retention test) of infant memory that are used in experiments involving infants' conditioned kicking. Compares these measures to a new measure, the fraction of kicking rate remaining after the retention interval. Explains the…

  15. Measuring thermal neutron characteristics

    International Nuclear Information System (INIS)

    Johnstone, C.W.; Jacobson, L.A.

    1983-01-01

    A method for providing a background-compensated measurement of the level of inducted radiation within an earth formation is claimed. The formation is irradiated with a discrete burst of neutrons and the level of radiation in the formation measured. The level of background radiation is then measured. An average level of both measurements is obtained

  16. Radon flux measurement methodologies

    International Nuclear Information System (INIS)

    Nielson, K.K.; Rogers, V.C.

    1984-01-01

    Five methods for measuring radon fluxes are evaluated: the accumulator can, a small charcoal sampler, a large-area charcoal sampler, the ''Big Louie'' charcoal sampler, and the charcoal tent sampler. An experimental comparison of the five flux measurement techniques was also conducted. Excellent agreement was obtained between the measured radon fluxes and fluxes predicted from radium and emanation measurements

  17. Measurement of communication

    International Nuclear Information System (INIS)

    1998-08-01

    This book is one of series of information communication, which deals with measurement of communication. It is divided into six chapters. The contents are foundation of measurement with classification and principle, Basic measurement on current, voltage, electric resistance, power and impedance, measurement of communication line with way by L3 tester, BW tester and pulse tester, measurement of optical fiber cable of equipment and method, Test and measurement of information communication equipment about test of modulator and use, measurement of cable broadcasting equipment on transmission level and main transmission equipment.

  18. Inspector measurement verification activities

    International Nuclear Information System (INIS)

    George, R.S.; Crouch, R.

    e most difficult and complex activity facing a safeguards inspector involves the verification of measurements and the performance of the measurement system. Remeasurement is the key to measurement verification activities. Remeasurerements using the facility's measurement system provide the bulk of the data needed for determining the performance of the measurement system. Remeasurements by reference laboratories are also important for evaluation of the measurement system and determination of systematic errors. The use of these measurement verification activities in conjunction with accepted inventory verification practices provides a better basis for accepting or rejecting an inventory. (U.S.)

  19. Broadband Radiometric LED Measurements

    OpenAIRE

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-01-01

    At present, broadband radiometric measurements of LEDs with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(��) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irr...

  20. Temperature Measurements in the Magnetic Measurement Facility

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Zachary

    2010-12-13

    Several key LCLS undulator parameter values depend strongly on temperature primarily because of the permanent magnet material the undulators are constructed with. The undulators will be tuned to have specific parameter values in the Magnetic Measurement Facility (MMF). Consequently, it is necessary for the temperature of the MMF to remain fairly constant. Requirements on undulator temperature have been established. When in use, the undulator temperature will be in the range 20.0 {+-} 0.2 C. In the MMF, the undulator tuning will be done at 20.0 {+-} 0.1 C. For special studies, the MMF temperature set point can be changed to a value between 18 C and 23 C with stability of {+-}0.1 C. In order to ensure that the MMF temperature requirements are met, the MMF must have a system to measure temperatures. The accuracy of the MMF temperature measurement system must be better than the {+-}0.1 C undulator tuning temperature tolerance, and is taken to be {+-}0.01 C. The temperature measurement system for the MMF is under construction. It is similar to a prototype system we built two years ago in the Sector 10 alignment lab at SLAC. At that time, our goal was to measure the lab temperature to {+-}0.1 C. The system has worked well for two years and has maintained its accuracy. For the MMF system, we propose better sensors and a more extensive calibration program to achieve the factor of 10 increase in accuracy. In this note we describe the measurement system under construction. We motivate our choice of system components and give an overview of the system. Most of the software for the system has been written and will be discussed. We discuss error sources in temperature measurements and show how these errors have been dealt with. The calibration system is described in detail. All the LCLS undulators must be tuned in the Magnetic Measurement Facility at the same temperature to within {+-}0.1 C. In order to ensure this, we are building a system to measure the temperature of the

  1. Power Curve Measurements REWS

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Vesth, Allan

    This report describes the power curve measurements carried out on a given wind turbine in a chosen period. The measurements were carried out following the measurement procedure in the draft of IEC 61400-12-1 Ed.2 [1], with some deviations mostly regarding uncertainty calculation. Here, the refere......This report describes the power curve measurements carried out on a given wind turbine in a chosen period. The measurements were carried out following the measurement procedure in the draft of IEC 61400-12-1 Ed.2 [1], with some deviations mostly regarding uncertainty calculation. Here......, the reference wind speed used in the power curve is the equivalent wind speed obtained from lidar measurements at several heights between lower and upper blade tip, in combination with a hub height meteorological mast. The measurements have been performed using DTU’s measurement equipment, the analysis...

  2. Vessel size measurements in angiograms: Manual measurements

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Dmochowski, Jacek; Nazareth, Daryl P.; Miskolczi, Laszlo; Nemes, Balazs; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2003-01-01

    Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical practice, choosing to indicate the edges of vessels and catheters to determine sizes and calibrate magnifications, i.e., manual measurements. Thus, we undertook an investigation of the accuracy and precision of vessel sizes calculated from manually indicated edges of vessels. Manual measurements were performed by three neuroradiologists and three physicists. Vessel sizes ranged from 0.1-3.0 mm in simulation studies and 0.3-6.4 mm in phantom studies. Simulation resolution functions had full-widths-at-half-maximum (FWHM) ranging from 0.0 to 0.5 mm. Phantom studies were performed with 4.5 in., 6 in., 9 in., and 12 in. image intensifier modes, magnification factor = 1, with and without zooming. The accuracy and reproducibility of the measurements ranged from 0.1 to 0.2 mm, depending on vessel size, resolution, and pixel size, and zoom. These results indicate that manual measurements may have accuracies comparable to automated techniques for vessels with sizes greater than 1 mm, but that automated techniques which take into account the resolution function should be used for vessels with sizes smaller than 1 mm

  3. Anatomical pulmonary magnetic resonance imaging segmentation for regional structure-function measurements of asthma

    Energy Technology Data Exchange (ETDEWEB)

    Guo, F. [Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5B7 (Canada); Graduate Program in Biomedical Engineering, University of Western Ontario, London, Ontario N6A 5B9 (Canada); Svenningsen, S.; Eddy, R. L.; Capaldi, D. P. I.; Sheikh, K. [Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5B7 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada); Fenster, A.; Parraga, G., E-mail: gparraga@robarts.ca [Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5B7 (Canada); Graduate Program in Biomedical Engineering, University of Western Ontario, London, Ontario N6A 5B9 (Canada); Department of Medical Biophysics, University of Western Ontario, London, Ontario N6A 5C1 (Canada)

    2016-06-15

    in a randomized dataset, on five occasions, five consecutive days in a row. Segmentation accuracy was evaluated using the Dice-similarity-coefficient (DSC) of the segmented thoracic cavity with comparison to five-rounds of manual segmentation by an expert observer. The authors also evaluated the root-mean-squared-error (RMSE) of the Euclidean distance between lung surfaces, the absolute, and percent volume error. Reproducibility was measured using the coefficient of variation (CoV) and intraclass correlation coefficient (ICC) for two observers who repeated segmentation measurements five-times. Results: For five well-controlled asthmatics, forced expiratory volume in 1 s (FEV{sub 1})/forced vital capacity (FVC) was 83% ± 7% and FEV{sub 1} was 86 ± 9%{sub pred}. For 15 severe, poorly controlled asthmatics, FEV{sub 1}/FV C = 66% ± 17% and FEV{sub 1} = 72 ± 27%{sub pred}. The DSC for algorithm and manual segmentation was 91% ± 3%, 92% ± 2% and 91% ± 2% for the left, right, and whole lung, respectively. RMSE was 4.0 ± 1.0 mm for each of the left, right, and whole lung. The absolute (percent) volume errors were 0.1 l (∼6%) for each of right and left lung and ∼0.2 l (∼6%) for whole lung. Intra- and inter-CoV (ICC) were <0.5% (>0.91%) for DSC and <4.5% (>0.93%) for RMSE. While segmentation required 10 s including ∼6 s for user interaction, the smallest detectable difference was 0.24 l for algorithm measurements which was similar to manual measurements. Conclusions: This lung segmentation approach provided the necessary and sufficient precision and accuracy required for research and clinical studies.

  4. Some mass measurement problems

    International Nuclear Information System (INIS)

    Merritt, J.S.

    1976-01-01

    Concerning the problem of determining the thickness of a target, an uncomplicated approach is to measure its mass and area and take the quotient. This paper examines the mass measurement aspect of such an approach. (author)

  5. Developing Effective Performance Measures

    Science.gov (United States)

    2014-10-14

    University When Performance Measurement Goes Bad Laziness Vanity Narcissism Too Many Pettiness Inanity 52 Developing Effective...Kasunic, October 14, 2014 © 2014 Carnegie Mellon University Narcissism Measuring performance from the organization’s point of view, rather than from

  6. AEROSOL AND GAS MEASUREMENT

    Science.gov (United States)

    Measurements provide fundamental information for evaluating and managing the impact of aerosols on air quality. Specific measurements of aerosol concentration and their physical and chemical properties are required by different users to meet different user-community needs. Befo...

  7. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Older Adults Overcoming Barriers Measuring Physical Activity Intensity Target Heart Rate & Estimated Maximum Heart Rate Perceived Exertion ( ... a heavy backpack Other Methods of Measuring Intensity Target Heart Rate and Estimated Maximum Heart Rate Perceived ...

  8. Estimation of measurement variances

    International Nuclear Information System (INIS)

    Jaech, J.L.

    1984-01-01

    The estimation of measurement error parameters in safeguards systems is discussed. Both systematic and random errors are considered. A simple analysis of variances to characterize the measurement error structure with biases varying over time is presented

  9. Emissions & Measurements - Black Carbon

    Science.gov (United States)

    Emissions and Measurement (EM) research activities performed within the National Risk Management Research Lab NRMRL) of EPA's Office of Research and Development (ORD) support measurement and laboratory analysis approaches to accurately characterize source emissions, and near sour...

  10. How Is PTSD Measured?

    Science.gov (United States)

    ... Public » Is it PTSD? » How is PTSD Measured? PTSD: National Center for PTSD Menu Menu PTSD PTSD Home For the Public ... code here Enter ZIP code here How is PTSD Measured? Public This section is for Veterans, General ...

  11. In praise of measurement

    International Nuclear Information System (INIS)

    Mermin, D.N.

    2005-01-01

    Full text: A quantum computer provides a toy universe in which to reexamine many aspects of quantum mechanics and quantum metaphysics. In particular measurement, against which John Bell unleashed one of his most elegant polemics, plays a transparent role. Since all measurements can be constructed out of identical 1-Qbit measurement gates, such obscurity as there is in the notion of measurement reduces to the obscurity, if any, of the elementary 1-Qbit gate. The 1-Qbit measurement gate is insufficiently celebrated. Without it the quantum computer has, in Abner Shimony's admirable words, 'no foreign policy'. Without it no computation has been done. without it no computation can begin. Without it there can be no error correction. Measurement takes coherence away but measurement also gives coherence. Praised be measurement. (author)

  12. Structural Measures - Hospital

    Data.gov (United States)

    U.S. Department of Health & Human Services — A list of hospitals and the structural measures they report. A structural measure reflects the environment in which hospitals care for patients, for example, whether...

  13. MDS Quality Measures

    Data.gov (United States)

    U.S. Department of Health & Human Services — A list of the quality measures displayed on Nursing Home Compare, excluding Measures of Rehospitalization, Emergency Room Visit, and Community Discharge. Each row...

  14. Measuring Pollution Prevention

    Science.gov (United States)

    Measuring results is an essential component of any successful P2 program and is one way to determine the success of a technical assistance or training effort. This page introduces the concept of P2 measurement.

  15. Reference values for spirometry in preschool children.

    Science.gov (United States)

    Burity, Edjane F; Pereira, Carlos A C; Rizzo, José A; Brito, Murilo C A; Sarinho, Emanuel S C

    2013-01-01

    Reference values for lung function tests differ in samples from different countries, including values for preschoolers. The main objective of this study was to derive reference values in this population. A prospective study was conducted through a questionnaire applied to 425 preschool children aged 3 to 6 years, from schools and day-care centers in a metropolitan city in Brazil. Children were selected by simple random sampling from the aforementioned schools. Peak expiratory flow (PEF), forced vital capacity (FVC), forced expiratory volumes (FEV1, FEV0.50), forced expiratory flow (FEF25-75) and FEV1/FVC, FEV0.5/FVC and FEF25-75/FVC ratios were evaluated. Of the 425 children enrolled, 321 (75.6%) underwent the tests. Of these, 135 (42.0%) showed acceptable results with full expiratory curves and thus were included in the regression analysis to define the reference values. Height and gender significantly influenced FVC values through linear and logarithmic regression analysis. In males, R(2) increased with the logarithmic model for FVC and FEV1, but the linear model was retained for its simplicity. The lower limits were calculated by measuring the fifth percentile residues. Full expiratory curves are more difficult to obtain in preschoolers. In addition to height, gender also influences the measures of FVC and FEV1. Reference values were defined for spirometry in preschool children in this population, which are applicable to similar populations. Copyright © 2013 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  16. Respiratory symptoms, spirometry, and oxidant air pollution in nonsmoking adults

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, C.A.; Hudson, A.R.; Clauson, J.L.; Knelson, J.H.

    1972-01-01

    Comparison of 197 nonsmokers (Seventh Day Adventists) residing in the San Gabriel Valley (high oxidant) with 244 living in San Diego area (similar pollution but with lower oxidant) is discussed. Study was conducted in winter when differences between the two areas were negligible and thus when irreversible effects could be detected. Some unusual findings included: an unexpectedly low chronic bronchitis prevalence rate of 1.77% as compared with the general population, a greater prevalence of chronic bronchitis in women in both areas (not significant), and no effect of socio-economic status. Comparison of pulmonary function using VC, FEV, MEF, peak flow, time constant, and FVC showed no differences between the two groups. The annual mean oxidant level is about the same in both areas and may have influenced spirometric values more than oxidant peaks. Also, these tests may not have been sufficiently sensitive.

  17. Spectrum and network measurements

    CERN Document Server

    Witte, Robert A

    2014-01-01

    This new edition of Spectrum and Network Measurements enables readers to understand the basic theory, relate it to measured results, and apply it when creating new designs. This comprehensive treatment of frequency domain measurements successfully consolidates all the pertinent theory into one text. It covers the theory and practice of spectrum and network measurements in electronic systems. It also provides thorough coverage of Fourier analysis, transmission lines, intermodulation distortion, signal-to-noise ratio and S-parameters.

  18. Temperature measuring device

    International Nuclear Information System (INIS)

    Brixy, H.

    1977-01-01

    The temperature measuring device is equipped with an electric resistor installed within a metal shroud tube so as to be insulated from it, the noise voltage of which resistor is fed to a measuring unit. The measuring junctions of one or two thermocouples are connected with the electric resistor and the legs of one or both thermocouples can be connected to the measuring unit by means of a switch. (orig.) [de

  19. Power Curve Measurements FGW

    DEFF Research Database (Denmark)

    Georgieva Yankova, Ginka; Federici, Paolo

    This report describes power curve measurements carried out on a given turbine in a chosen period. The measurements are carried out in accordance to IEC 61400-12-1 Ed. 1 and FGW Teil 2.......This report describes power curve measurements carried out on a given turbine in a chosen period. The measurements are carried out in accordance to IEC 61400-12-1 Ed. 1 and FGW Teil 2....

  20. Strain measurement technique

    International Nuclear Information System (INIS)

    1987-01-01

    The 10 contributions are concerned with selected areas of application, such as strain measurements in wood, rubber/metal compounds, sets of strain measurements on buildings, reinforced concrete structures without gaps, pipes buried in the ground and measurements of pressure fluctuations. To increase the availability and safety of plant, stress analyses were made on gas turbine rotors with HT-DMS or capacitive HT-DMS (high temperature strain measurements). (DG) [de

  1. Foundations of measurement

    CERN Document Server

    Suppes, Patrick

    1989-01-01

    Foundations of Measurement offers the most coherently organized treatment of the topics and issues central to measurement. Much of the research involved has been scattered over several decades and a multitude of journals--available in many instances only to specialties. With the publication of Volumes two and three of this important work, Foundations of Measurement is the most comprehensive presentation in the area of measurement.

  2. Reconsidering Formative Measurement

    Science.gov (United States)

    Howell, Roy D.; Breivik, Einar; Wilcox, James B.

    2007-01-01

    The relationship between observable responses and the latent constructs they are purported to measure has received considerable attention recently, with particular focus on what has become known as formative measurement. This alternative to reflective measurement in the area of theory-testing research is examined in the context of the potential…

  3. Power Curve Measurements

    DEFF Research Database (Denmark)

    Federici, Paolo; Kock, Carsten Weber

    This report describes the power curve measurements performed with a nacelle LIDAR on a given wind turbine in a wind farm and during a chosen measurement period. The measurements and analysis are carried out in accordance to the guidelines in the procedure “DTU Wind Energy-E-0019” [1]. The reporting...

  4. Power Curve Measurements, FGW

    DEFF Research Database (Denmark)

    Vesth, Allan; Kock, Carsten Weber

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...... analyze of power performance of the turbine....

  5. Power Curve Measurements

    DEFF Research Database (Denmark)

    Federici, Paolo; Vesth, Allan

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...... analyze of power performance of the turbine....

  6. Power Curve Measurements

    DEFF Research Database (Denmark)

    Villanueva, Héctor; Gómez Arranz, Paula

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...... analyze of power performance of the turbine...

  7. Standards for holdup measurement

    International Nuclear Information System (INIS)

    Zucker, M.S.

    1982-01-01

    Holdup measurement, needed for material balance, depend intensively on standards and on interpretation of the calibration procedure. More than other measurements, the calibration procedure using the standard becomes part of the standard. Standards practical for field use and calibration techniques have been developed. While accuracy in holdup measurements is comparatively poor, avoidance of bias is a necessary goal

  8. Coating thickness measurement

    International Nuclear Information System (INIS)

    1976-12-01

    The standard specifies measurements of the coating thickness, which make use of beta backscattering and/or x-ray fluorescence. For commonly used combinations of coating material and base material the appropriate measuring ranges and radionuclides to be used are given for continuous as well as for discontinuous measurements

  9. Measuring agricultural policy bias

    DEFF Research Database (Denmark)

    Jensen, Henning Tarp; Robinson, Sherman; Tarp, Finn

    2010-01-01

    Measurement is a key issue in the literature on price incentive bias induced by trade policy. We introduce a general equilibrium measure of the relative effective rate of protection, which generalizes earlier protection measures. For our fifteen sample countries, results indicate that the agricul...

  10. Power Curve Measurements FGW

    DEFF Research Database (Denmark)

    Federici, Paolo; Kock, Carsten Weber

    The report describes power curve measurements carried out on a given wind turbine. The measurements are carried out in accordance to Ref. [1]. A site calibration has been carried out; see Ref. [2], and the measured flow correction factors for different wind directions are used in the present...... analyze of power performance of the turbine...

  11. Estimation of measurement variances

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    In the previous two sessions, it was assumed that the measurement error variances were known quantities when the variances of the safeguards indices were calculated. These known quantities are actually estimates based on historical data and on data generated by the measurement program. Session 34 discusses how measurement error parameters are estimated for different situations. The various error types are considered. The purpose of the session is to enable participants to: (1) estimate systematic error variances from standard data; (2) estimate random error variances from data as replicate measurement data; (3) perform a simple analysis of variances to characterize the measurement error structure when biases vary over time

  12. Measure and integration theory

    CERN Document Server

    Burckel, Robert B

    2001-01-01

    This book gives a straightforward introduction to the field as it is nowadays required in many branches of analysis and especially in probability theory. The first three chapters (Measure Theory, Integration Theory, Product Measures) basically follow the clear and approved exposition given in the author's earlier book on ""Probability Theory and Measure Theory"". Special emphasis is laid on a complete discussion of the transformation of measures and integration with respect to the product measure, convergence theorems, parameter depending integrals, as well as the Radon-Nikodym theorem. The fi

  13. Precision electroweak measurements

    International Nuclear Information System (INIS)

    Demarteau, M.

    1996-11-01

    Recent electroweak precision measurements fro e + e - and p anti p colliders are presented. Some emphasis is placed on the recent developments in the heavy flavor sector. The measurements are compared to predictions from the Standard Model of electroweak interactions. All results are found to be consistent with the Standard Model. The indirect constraint on the top quark mass from all measurements is in excellent agreement with the direct m t measurements. Using the world's electroweak data in conjunction with the current measurement of the top quark mass, the constraints on the Higgs' mass are discussed

  14. Measurement of true density

    International Nuclear Information System (INIS)

    Carr-Brion, K.G.; Keen, E.F.

    1982-01-01

    System for determining the true density of a fluent mixture such as a liquid slurry, containing entrained gas, such as air comprises a restriction in pipe through which at least a part of the mixture is passed. Density measuring means such as gamma-ray detectors and source measure the apparent density of the mixture before and after its passage through the restriction. Solid-state pressure measuring devices are arranged to measure the pressure in the mixture before and after its passage through the restriction. Calculating means, such as a programmed microprocessor, determine the true density from these measurements using relationships given in the description. (author)

  15. Coordinate measuring machines

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo

    This document is used in connection with three exercises of 2 hours duration as a part of the course GEOMETRICAL METROLOGY AND MACHINE TESTING. The exercises concern three aspects of coordinate measuring: 1) Measuring and verification of tolerances on coordinate measuring machines, 2) Traceabilit...... and uncertainty during coordinate measurements, 3) Digitalisation and Reverse Engineering. This document contains a short description of each step in the exercise and schemes with room for taking notes of the results.......This document is used in connection with three exercises of 2 hours duration as a part of the course GEOMETRICAL METROLOGY AND MACHINE TESTING. The exercises concern three aspects of coordinate measuring: 1) Measuring and verification of tolerances on coordinate measuring machines, 2) Traceability...

  16. Comparison of five portable peak flow meters

    Directory of Open Access Journals (Sweden)

    Glaucia Nency Takara

    2010-01-01

    Full Text Available OBJECTIVE: To compare the measurements of spirometric peak expiratory flow (PEF from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. METHODS: Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (p<0.05, Spearman's correlation test and Bland-Altman's agreement test. RESULTS: The median and interquartile ranges for the spirometric values and the Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® meters were 428 (263-688 L/min, 450 (350-800 L/min, 420 (310-720 L/min, 380 (300-735 L/min, 400 (310-685 L/min and 415 (335-610 L/min, respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone® (p<0.001 and Galemed ® (p<0.01 meters. There was no agreement between the spirometric values and the five PEF meters. CONCLUSIONS: The results suggest that the values recorded from Galemed® meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone® meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  17. Planimetric determination of lung volume

    International Nuclear Information System (INIS)

    Bieber, M.; Maurer, H.J.

    1984-01-01

    The total volume of the lungs was determined by digital planimetry in 102 patients with emphysema and 33 normal controls aged between 30 and 79 years. The results were compared with the findings obtained from spirometric measurements. Mean values showed a significant relationship to age, body size and body surface. Planimetrically determined lung volume did not show a linear relationship with age, but increased after 60 years. Beyong 60 years, spirometric findings were lower because of an increase in the number of patients with emphysema. The results have shown that digital planimetry is a useful addition to spirometry. (orig.) [de

  18. Performance Measurement und Environmental Performance Measurement

    OpenAIRE

    Sturm, Anke

    2000-01-01

    Die Zielsetzung der vorliegenden Dissertationsschrift besteht in der Entwicklung einer systematisierten Vorgehensweise, eines Controllingmodells, zur unternehmensinternen Umweltleistungsmessung. Das entwickelte Environmental Performance Measurement (EPM)-Modell umfaßt die fünf Stufen Festlegung der Ziele der Umweltleistungsmessung (1. Stufe), Erfassung der Umwelteinflüsse nach der ökologischen Erfolgsspaltung (2. Stufe), Bewertung der Umwelteinflüsse auf der Grundlage des qualitätszielbezogen...

  19. Spirometry of healthy adult South African men

    African Journals Online (AJOL)

    1996-07-07

    Jul 7, 1996 ... radiographic screening process was used to identify a healthy population ... significantly lower values than the Autolink for FVC measurements despite .... t Medical Instrumentation. ATS '" American ... Quality control. Biological ...

  20. Measurement control program

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    A measurement control program for the model plant is described. The discussion includes the technical basis for such a program, the application of measurement control principles to each measurement, and the use of special experiments to estimate measurement error parameters for difficult-to-measure materials. The discussion also describes the statistical aspects of the program, and the documentation procedures used to record, maintain, and process the basic data. The purpose of the session is to enable participants to: (1) understand the criteria for this type of a measurement control program; (2) understand the kinds of physical standards required for the various measurement processes, e.g., weighing, analytical, NDA; (3) understand the need for and importance of a measurement control program; (4) understand the need for special experiments to provide an improved basis for the measurement of difficult-to-measure materials; (5) understand the general scope of the program's statistical aspects; and (6) understand the basis and scope of the documentation procedures

  1. Genetic and Environmental Influences on Pulmonary Function and Muscle Strength: The Chinese Twin Study of Aging

    DEFF Research Database (Denmark)

    Tian, Xiaocao; Xu, Chunsheng; Wu, Yili

    2017-01-01

    Genetic and environmental influences on predictors of decline in daily functioning, including forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), handgrip, and five-times-sit-to-stand test (FTSST), have not been addressed in the aging Chinese population. We performed classical twin...... was moderate for FEV1, handgrip, and FTSST (55-60%) but insignificant for FVC. Only FVC showed moderate control, with shared environmental factors accounting for about 50% of the total variance. In contrast, all measures of pulmonary function and muscle strength showed modest influences from the unique...

  2. Obstructive lung disease as a complication in post pulmonary TB

    Science.gov (United States)

    Tarigan, A. P.; Pandia, P.; Eyanoer, P.; Tina, D.; Pratama, R.; Fresia, A.; Tamara; Silvanna

    2018-03-01

    The case of post TB is a problem that arises in the community. Pulmonary tuberculosis (TB) can affect lung function. Therefore, we evaluated impaired pulmonary function in subjects with diagnosed prior pulmonary TB. A Case Series study, pulmonary function test was performed in subjects with a history of pulmonary tuberculosis; aged ≥18 years were included. Exclusion criteria was a subject who had asthma, obesity, abnormal thorax and smoking history. We measured FEV1 and FVC to evaluate pulmonary function. Airflow obstruction was FEV1/FVC%pulmonary TB, 5 subjects (23%) had airflow obstruction with FEV1/FVC% value pulmonary TB.

  3. Meta-analyses of genome-wide association studies identify multiple loci associated with pulmonary function

    NARCIS (Netherlands)

    D.B. Hancock (Dana); M. Eijgelsheim (Mark); J.B. Wilk (Jemma); S.A. Gharib (Sina); L.R. Loehr (Laura); K. Marciante (Kristin); N. Franceschini (Nora); Y.M.T.A. van Durme; T.H. Chen; R.G. Barr (Graham); M.B. Schabath (Matthew); D.J. Couper (David); G.G. Brusselle (Guy); B.M. Psaty (Bruce); P. Tikka-Kleemola (Päivi); J.I. Rotter (Jerome); A.G. Uitterlinden (André); A. Hofman (Albert); N.M. Punjabi (Naresh); F. Rivadeneira Ramirez (Fernando); A.C. Morrison (Alanna); P.L. Enright (Paul); K.E. North (Kari); S.R. Heckbert (Susan); T. Lumley (Thomas); B.H.Ch. Stricker (Bruno); G.T. O'Connor (George); S.J. London (Stephanie)

    2010-01-01

    textabstractSpirometric measures of lung function are heritable traits that reflect respiratory health and predict morbidity and mortality. We meta-analyzed genome-wide association studies for two clinically important lung-function measures: forced expiratory volume in the first second (FEV1) and

  4. Positive Rates and Factors Associated with Abnormal Lung Function of Greenhouse Workers in China: A Cross-Sectional Study.

    Science.gov (United States)

    Zhu, Xiaojun; Gao, Panjun; Gu, Yishuo; Xiao, Pei; Liu, Mengxuan; Chen, Juan; Cen, Yacai; Ma, Wenjun; Li, Tao

    2017-08-24

    Since the number of greenhouse workers are increasing in China, this observational cross-sectional study was designed to evaluate lung function and discuss the potential risk factors, to provide evidence in the surveillance of greenhouse workers' health. 678 greenhouse workers in Gansu Province, China were enrolled. A questionnaire which included demographic and occupational information was used. Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 s (FEV₁), and FEV₁:FVC ratios (FEV₁/FVC), maximal expiratory flow after 50% of the FVC has not been exhaled (MEF 50 ), maximal expiratory flow after 25% of the FVC has not been exhaled (MEF 25 ) and maximal mid-expiratory flow curve (MMEF) were measured as lung function indicators. The mean values and standard deviations (SDs) of VC% predicted, FVC% predicted, FEV₁% predicted and FEV₁/FVC ratio were 106.07 ± 13.36, 107.60 ± 13.95, 97.19 ± 14.80 and 89.76 ± 10.78 respectively. The positive rates of above four and abnormal lung ventilation function were 2.9%, 2.8%, 11.2%, 4.6% and 6.5% respectively. Gender, age, BMI and number of greenhouses owned were influence factors of lung ventilation function ( p greenhouses owned were influence factors for small airway function ( p greenhouse might influence lung function of the workers. Small airway function indicators could be used as priority indicators for the surveillance of greenhouse workers' health.

  5. Evaluation of accountability measurements

    International Nuclear Information System (INIS)

    Cacic, C.G.

    1988-01-01

    The New Brunswick Laboratory (NBL) is programmatically responsible to the U.S. Department of Energy (DOE) Office of Safeguards and Security (OSS) for providing independent review and evaluation of accountability measurement technology in DOE nuclear facilities. This function is addressed in part through the NBL Safegaurds Measurement Evaluation (SME) Program. The SME Program utilizes both on-site review of measurement methods along with material-specific measurement evaluation studies to provide information concerning the adequacy of subject accountability measurements. This paper reviews SME Program activities for the 1986-87 time period, with emphasis on noted improvements in measurement capabilities. Continued evolution of the SME Program to respond to changing safeguards concerns is discussed

  6. Sport-specific influences on respiratory patterns in elite athletes.

    Science.gov (United States)

    Durmic, Tijana; Lazovic, Biljana; Djelic, Marina; Lazic, Jelena Suzic; Zikic, Dejan; Zugic, Vladimir; Dekleva, Milica; Mazic, Sanja

    2015-01-01

    To examine differences in lung function among sports that are of a similar nature and to determine which anthropometric/demographic characteristics correlate with lung volumes and flows. This was a cross-sectional study involving elite male athletes (N = 150; mean age, 21  4 years) engaging in one of four different sports, classified according to the type and intensity of exercise involved. All athletes underwent full anthropometric assessment and pulmonary function testing (spirometry). Across all age groups and sport types, the elite athletes showed spirometric values that were significantly higher than the reference values. We found that the values for FVC, FEV1, vital capacity, and maximal voluntary ventilation were higher in water polo players than in players of the other sports evaluated (p respiratory system. That knowledge is particularly important when athletes present with respiratory symptoms such as dyspnea, cough, and wheezing. Because sports medicine physicians use predicted (reference) values for spirometric parameters, the risk that the severity of restrictive disease or airway obstruction will be underestimated might be greater for athletes.

  7. Efficiency of lung ventilation for people performing wind instruments.

    Science.gov (United States)

    Brzęk, Anna; Famuła, Anna; Kowalczyk, Anna; Plinta, Ryszard

    Wind instruments musicians are particularly prone to excessive respiratory efforts. Prolonged wind instruments performing may lead to changes in respiratory tracts and thus to respiratory muscles overload. It may result in decreasing lung tissue pliability and, as a consequence, in emphysema. Aim of the research has been to describe basic spirometric parameters for wind players and causes of potential changes. Slow and forced spirometry with the use of Micro Lab Viasys (Micro Medical, Great Britain) was conducted on 31 wind musicians (group A). A survey concerning playing time and frequency, weight of instruments, and education on diaphragmatic breathing was conducted. The control group included 34 healthy persons at similar age (group B). The results were statistically described using Excel and Statistica programmes. The respiratory parameters were within the range of physiological norms and forced expiratory volume in 1 s to forced vital capacity (FEV1/FVC) exceeded in both groups the values of 100%. Forced vital capacity and expiratory vital capacity (EVC) values were significantly lower in the group of musicians than in the control group (p wind instrument. Spirometric parameters relative to standards may prove a good respiratory capacity. Peak expiratory flow (PEF) and FEV1 may indicate that a proper technique of respiration during performance was acquired. The length of time when performing wind instrument may influence parameters of dynamic spirometry. Med Pr 2016;67(4):427-433. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  8. Diagnostic Instability and Reversals of Chronic Obstructive Pulmonary Disease Diagnosis in Individuals with Mild to Moderate Airflow Obstruction.

    Science.gov (United States)

    Aaron, Shawn D; Tan, Wan C; Bourbeau, Jean; Sin, Don D; Loves, Robyn H; MacNeil, Jenna; Whitmore, George A

    2017-08-01

    Chronic obstructive pulmonary disease (COPD) is a chronic, progressive disease, and reversal of COPD diagnosis is thought to be uncommon. To determine whether a spirometric diagnosis of mild or moderate COPD is subject to variability and potential error. We examined two prospective cohort studies that enrolled subjects with mild to moderate post-bronchodilator airflow obstruction. The Lung Health Study (n = 5,861 subjects; study duration, 5 yr) and the Canadian Cohort of Obstructive Lung Disease (CanCOLD) study (n = 1,551 subjects; study duration, 4 yr) were examined to determine frequencies of (1) diagnostic instability, represented by how often patients initially met criteria for a spirometric diagnosis of COPD but then crossed the diagnostic threshold to normal and then crossed back to COPD over a series of annual visits, or vice versa; and (2) diagnostic reversals, defined as how often an individual's COPD diagnosis at the study outset reversed to normal by the end of the study. Diagnostic instability was common and occurred in 19.5% of the Lung Health Study subjects and 6.4% of the CanCOLD subjects. Diagnostic reversals of COPD from the beginning to the end of the study period occurred in 12.6% and 27.2% of subjects in the Lung Health Study and CanCOLD study, respectively. The risk of diagnostic instability was greatest for subjects whose baseline FEV 1 /FVC value was closest to the diagnostic threshold, and the risk of diagnostic reversal was greatest for subjects who quit smoking during the study. A single post-bronchodilator spirometric assessment may not be reliable for diagnosing COPD in patients with mild to moderate airflow obstruction at baseline.

  9. An approach to measurement

    International Nuclear Information System (INIS)

    Gudder, S.P.

    1984-01-01

    A new approach to measurement theory is presented. The definition of measurement is motivated by direct laboratory procedures as they are carried out in practice. The theory is developed within the quantum logic framework. The work clarifies an important problem in the quantum logic approach; namely, where the Hilbert space comes from. The relationship between measurements and observables is considered, and a Hilbert space embedding theorem is presented. Charge systems are also discussed. (author)

  10. Decoherence and quantum measurements

    CERN Document Server

    Namiki, Mikio; Pascazio, Saverio

    1997-01-01

    The quantum measurement problem is one of the most fascinating and challenging topics in physics both theoretically and experimentally. It involves deep questions and the use of very sophisticated and elegant techniques. After analyzing the fundamental principles of quantum mechanics and of the Copenhagen interpretation, this book reviews the most important approaches to the measurement problem and rigorously reformulates the "collapse of the wave function" by measurement, as a dephasing process quantitatively characterized by an order parameter (called the decoherence parameter), according to

  11. Betatron tune measurement

    International Nuclear Information System (INIS)

    Dinev, D.

    2001-01-01

    On the basis of the comparative review of the methods for the betatron tune measurement in cyclic accelerators of synchrotrons type, the research of these methods is carried out from the point of view of their applicability to Nuclotron. Both methods using measurement of the statistical fluctuations of the beam current (Schottky noise) and methods using coherent beam excitation have been discussed. The emphasis is on the final results of importance for the tune measurement practice. Signal processing is briefly discussed too

  12. Broadband radiometric LED measurements

    Science.gov (United States)

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-09-01

    At present, broadband radiometric LED measurements with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed.

  13. Radioisotope measurement system

    International Nuclear Information System (INIS)

    Villanueva Ruibal, Jose

    2007-01-01

    A radioisotope measurement system installed at L.M.R. (Ezeiza Atomic Center of CNEA) allows the measurement of nuclear activity from a wide range of radioisotopes. It permits to characterize a broad range of radioisotopes at several activity levels. The measurement hardware as well as the driving software have been developed and constructed at the Dept. of Instrumentation and Control. The work outlines the system's conformation and its operating concept, describes design characteristics, construction and the error treatment, comments assay results and supplies use advices. Measuring tests carried out employing different radionuclides confirmed the system performing satisfactorily and with friendly operation. (author) [es

  14. Aperture area measurement facility

    Data.gov (United States)

    Federal Laboratory Consortium — NIST has established an absolute aperture area measurement facility for circular and near-circular apertures use in radiometric instruments. The facility consists of...

  15. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Healthy Weight Breastfeeding Micronutrient Malnutrition State and Local Programs Measuring Physical Activity Intensity Recommend on Facebook Tweet Share Compartir For more help with what ...

  16. Atmospheric Measurements Laboratory (AML)

    Data.gov (United States)

    Federal Laboratory Consortium — The Atmospheric Measurements Laboratory (AML) is one of the nation's leading research facilities for understanding aerosols, clouds, and their interactions. The AML...

  17. Semiconductor Laser Measurements Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Semiconductor Laser Measurements Laboratory is equipped to investigate and characterize the lasing properties of semiconductor diode lasers. Lasing features such...

  18. The attribute measurement technique

    International Nuclear Information System (INIS)

    MacArthur, Duncan W.; Langner, Diana; Smith, Morag; Thron, Jonathan; Razinkov, Sergey; Livke, Alexander

    2010-01-01

    Any verification measurement performed on potentially classified nuclear material must satisfy two seemingly contradictory constraints. First and foremost, no classified information can be released. At the same time, the monitoring party must have confidence in the veracity of the measurement. An information barrier (IB) is included in the measurement system to protect the potentially classified information while allowing sufficient information transfer to occur for the monitoring party to gain confidence that the material being measured is consistent with the host's declarations, concerning that material. The attribute measurement technique incorporates an IB and addresses both concerns by measuring several attributes of the nuclear material and displaying unclassified results through green (indicating that the material does possess the specified attribute) and red (indicating that the material does not possess the specified attribute) lights. The attribute measurement technique has been implemented in the AVNG, an attribute measuring system described in other presentations at this conference. In this presentation, we will discuss four techniques used in the AVNG: (1) the 1B, (2) the attribute measurement technique, (3) the use of open and secure modes to increase confidence in the displayed results, and (4) the joint design as a method for addressing both host and monitor needs.

  19. Measuring School Contexts

    Directory of Open Access Journals (Sweden)

    Chandra L. Muller PhD

    2015-11-01

    Full Text Available This article describes issues in measuring school contexts with an eye toward understanding students’ experiences and outcomes. I begin with an overview of the conceptual underpinnings related to measuring contexts, briefly describe the initiatives at the National Center for Education Statistics to measure school contexts, and identify possible gaps in those initiatives that if filled could provide valuable new data for researchers. Next, I discuss new approaches and opportunities for measurement, and special considerations related to diverse populations and youth development. I conclude with recommendations for future priorities.

  20. Luminosity measurement at AMY

    International Nuclear Information System (INIS)

    Kurihara, Y.

    1995-01-01

    A precise measurement of a luminosity is required by experiments with high statistics. The largest sources of a systematic error of a luminosity measurement are an alignment of the tube chambers which measure a polar angle of Bhabha events and a higher order correction for the Bhabha cross section calculation. We describe a resent study for these uncertainties and how to reduce the systematic errors from these sources. The total systematic error of the luminosity measurement of 1.8% can be reduced to 1.0% by this study. (author)

  1. Young Measures and Compactness in Measure Spaces

    CERN Document Server

    Florescu, Liviu C

    2012-01-01

    Many problems in science can be formulated in the language of optimization theory, in which case an optimal solution or the best response to a particular situation is required. In situations of interest, such classical optimal solutions are lacking, or at least, the existence of such solutions is far from easy to prove. So, non-convex optimization problems may not possess a classical solution because approximate solutions typically show rapid oscillations. This phenomenon requires the extension of such problems' solution often constructed by means of Young measures. This book is written to int

  2. Regularities of Multifractal Measures

    Indian Academy of Sciences (India)

    First, we prove the decomposition theorem for the regularities of multifractal Hausdorff measure and packing measure in R R d . This decomposition theorem enables us to split a set into regular and irregular parts, so that we can analyze each separately, and recombine them without affecting density properties. Next, we ...

  3. Similarity Measure of Graphs

    Directory of Open Access Journals (Sweden)

    Amine Labriji

    2017-07-01

    Full Text Available The topic of identifying the similarity of graphs was considered as highly recommended research field in the Web semantic, artificial intelligence, the shape recognition and information research. One of the fundamental problems of graph databases is finding similar graphs to a graph query. Existing approaches dealing with this problem are usually based on the nodes and arcs of the two graphs, regardless of parental semantic links. For instance, a common connection is not identified as being part of the similarity of two graphs in cases like two graphs without common concepts, the measure of similarity based on the union of two graphs, or the one based on the notion of maximum common sub-graph (SCM, or the distance of edition of graphs. This leads to an inadequate situation in the context of information research. To overcome this problem, we suggest a new measure of similarity between graphs, based on the similarity measure of Wu and Palmer. We have shown that this new measure satisfies the properties of a measure of similarities and we applied this new measure on examples. The results show that our measure provides a run time with a gain of time compared to existing approaches. In addition, we compared the relevance of the similarity values obtained, it appears that this new graphs measure is advantageous and  offers a contribution to solving the problem mentioned above.

  4. Measures of Pleasures

    NARCIS (Netherlands)

    S.J. Magala (Slawomir)

    2002-01-01

    textabstractMeasuring culture originated in cultural anthropology, but all social sciences contributed to comparative cultural studies. Tracing critical approaches towards a measurement of cultural values one is bound to strip the biases and stereotypes bare and to invade numerous academic fiefs.

  5. Measuring Mobile Phone Use

    DEFF Research Database (Denmark)

    Boase, Jeff; Ling, Richard

    2013-01-01

    In this paper we examine how well two types of self-report measures adequately operationalize frequency of mobile phone use by comparing them to server log data. Our self-report measures of voice and SMS text messaging activity are drawn from a nationally representative survey of adults living...

  6. Mechanical Measurements Laboratory

    CERN Multimedia

    Maximilien Brice

    2007-01-01

    The CERN mechanical measurements team check the sensors on one of the ATLAS inner detector end-caps using high precision measurement equipment. Remote checks like this must be made on these sensitive detector components before they can be transported to make sure that all systems are working correctly.

  7. Auditing measurement control programs

    International Nuclear Information System (INIS)

    Roberts, F.P.; Brouns, R.J.

    1979-10-01

    Requirements and a general procedure for auditing measurement control programs used in special nuclear material accounting are discussed. The areas of measurement control that need to be examined are discussed and a suggested checklist is included to assist in the preparation and performance of the audit

  8. Measuring Relational Reasoning

    Science.gov (United States)

    Alexander, Patricia A.; Dumas, Denis; Grossnickle, Emily M.; List, Alexandra; Firetto, Carla M.

    2016-01-01

    Relational reasoning is the foundational cognitive ability to discern meaningful patterns within an informational stream, but its reliable and valid measurement remains problematic. In this investigation, the measurement of relational reasoning unfolded in three stages. Stage 1 entailed the establishment of a research-based conceptualization of…

  9. Measurement of surface roughness

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo

    This document is used in connection with two 3 hours laboratory exercises that are part of the course GEOMETRICAL METROLOGY AND MACHINE TESTING. The laboratories include a demonstration of the function of roughness measuring instruments plus a series of exercises illustrating roughness measurement...

  10. Measuring regional authority

    NARCIS (Netherlands)

    Marks, G.W.; Hooghe, E.A.E.B.; Schakel, A.H.

    2008-01-01

    This article sets out a conceptual basis for measuring regional authority and engages basic measurement issues. Regional authority is disaggregated into two domains (self-rule and shared rule) and these are operationalised in eight dimensions. The article concludes by examining the robustness of

  11. Meteorological measurements. Chapter 3

    Science.gov (United States)

    David Y. Hollinger

    2008-01-01

    Environmental measurements are useful for detecting climatic trends, understanding how the environment influences biological processes, and as input to ecosystem models. Landscape-scale monitoring requires a suite of environmental measures for all of these purposes, including air and soil temperature, humidity, wind speed, precipitation and soil moisture, and different...

  12. Metrology Measurement Capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Glen E. Gronniger

    2007-10-02

    This document contains descriptions of Federal Manufacturing & Technologies (FM&T) Metrology capabilities, traceability flow charts, and the measurement uncertainty of each measurement capability. Metrology provides NIST traceable precision measurements or equipment calibration for a wide variety of parameters, ranges, and state-of-the-art uncertainties. Metrology laboratories conform to the requirements of the Department of Energy Development and Production Manual Chapter 13.2, ANSI/ISO/IEC ANSI/ISO/IEC 17025:2005, and ANSI/NCSL Z540-1. FM&T Metrology laboratories are accredited by NVLAP for the parameters, ranges, and uncertainties listed in the specific scope of accreditation under NVLAP Lab code 200108-0. See the Internet at http://ts.nist.gov/Standards/scopes/2001080.pdf. These parameters are summarized. The Honeywell Federal Manufacturing & Technologies (FM&T) Metrology Department has developed measurement technology and calibration capability in four major fields of measurement: (1) Mechanical; (2) Environmental, Gas, Liquid; (3) Electrical (DC, AC, RF/Microwave); and (4) Optical and Radiation. Metrology Engineering provides the expertise to develop measurement capabilities for virtually any type of measurement in the fields listed above. A strong audit function has been developed to provide a means to evaluate the calibration programs of our suppliers and internal calibration organizations. Evaluation includes measurement audits and technical surveys.

  13. Low Absorbance Measurements

    Science.gov (United States)

    Harris, T. D.; Williams, A. M.

    1983-10-01

    The application of low absorption measurements to dilute solute determination requires specific instrumental characteristics. The use of laser intracavity absorption and thermal lens calorimetry to measure concentration is shown. The specific operating parameters that determine sensitivity are delineated along with the limits different measurement strategies impose. Finally areas of improvement in components that would result in improve sensitivity, accuracy, and reliability are discussed. During the past decade, a large number of methods have been developed for measuring the light absorbed by transparent materials. These include measurements on gases, liquids, and solids. The activity has been prompted by a variety of applications and a similar variety of disciplines. In Table 1 some representative examples of these methods is shown along with their published detection limits.1 It is clear that extraordinarily small absorbances can be measured. Most of the methods can be conveniently divided into two groups. These groups are those that measure the transmission of the sample and those that measure the light absorbed by the sample. The light absorbed methods are calorimetric in character. The advantages and disadvantages of each method varies depending on the principal application for which they were developed. The most prevalent motivation has been to characterize the bulk optical properties of transparent materials. Two examples are the development of extremely transparent glasses for use as fiber optic materials and the development of substrates for high power laser operation.

  14. Dynamics via measurability

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available Generators f for σ -algebras can be used to view the dynamics of an invertible measurable transformation T in terms of the range values of f ∘ T . Such generators are the norm rather than the exception. Related measurable and quantitative methods of estimating a function from the behavior of ergodic averages are also discussed.

  15. Global Precipitation Measurement Poster

    Science.gov (United States)

    Azarbarzin, Art

    2010-01-01

    This poster presents an overview of the Global Precipitation Measurement (GPM) constellation of satellites which are designed to measure the Earth's precipitation. It includes the schedule of launches for the various satellites in the constellation, and the coverage of the constellation, It also reviews the mission capabilities, and the mission science objectives.

  16. Measuring internet skills

    NARCIS (Netherlands)

    van Deursen, Alexander Johannes Aloysius Maria; van Dijk, Johannes A.G.M.

    2010-01-01

    Research that considers Internet skills often lacks theoretical justifications and does not go beyond basic button knowledge. There is a strong need for a measurement framework that can guide future research. In this article, operational definitions for measuring Internet skills are proposed,

  17. Measurement in Sustainable Building

    DEFF Research Database (Denmark)

    Hale, Lara

    2018-01-01

    Measurement is a necessary aspect of planning and constructing buildings. However, recent attempts to integrate the social dimension of sustainable building into building design and specifications demand measurement of non-technical qualities, such as well-being. The Active House Alliance, in lieu...... and continued provision of sustainable buildings to market demand....

  18. Measuring bothersome menopausal symptoms

    DEFF Research Database (Denmark)

    Lund, Kamma Sundgaard; Siersma, Volkert Dirk; Christensen, Karl Bang

    2018-01-01

    BACKGROUND: The experience of menopausal symptoms is common and an adequate patient-reported outcome measure is crucial in studies where women are treated for these symptoms. The aims of this study were to identify a patient-reported outcome measure for bothersome menopausal symptoms and, in the ...

  19. Measuring Authoritative Teaching

    Science.gov (United States)

    Ertesvag, Sigrun K.

    2011-01-01

    High quality measurements are important to evaluate interventions. The study reports on the development of a measurement to investigate authoritative teaching understood as a two-dimensional construct of warmth and control. Through the application of confirmatory factor analysis (CFA) and structural equation modelling (SEM) the factor structure…

  20. Measuring innovative work behaviour

    NARCIS (Netherlands)

    de Jong, J.; den Hartog, D.

    2010-01-01

    Both scientists and practitioners emphasize the importance of innovative work behaviour (IWB) of individual employees for organizational success, but the measurement of IWB is still at an evolutionary stage. This article is concerned with developed a measure of IWB with four potential dimensions:

  1. Measuring News Media Literacy

    Science.gov (United States)

    Maksl, Adam; Ashley, Seth; Craft, Stephanie

    2015-01-01

    News media literacy refers to the knowledge and motivations needed to identify and engage with journalism. This study measured levels of news media literacy among 500 teenagers using a new scale measure based on Potter's model of media literacy and adapted to news media specifically. The adapted model posits that news media literate individuals…

  2. Measures of Biochemical Sociology

    Science.gov (United States)

    Snell, Joel; Marsh, Mitchell

    2008-01-01

    In a previous article, the authors introduced a new sub field in sociology that we labeled "biochemical sociology." We introduced the definition of a sociology that encompasses sociological measures, psychological measures, and biological indicators Snell & Marsh (2003). In this article, we want to demonstrate a research strategy that would assess…

  3. Measures of Student Growth

    Science.gov (United States)

    Texas Education Agency, 2016

    2016-01-01

    Beginning in the 2017-2018 school year, appraisal systems in Texas, whether the state-recommended system or a locally developed system, will need to include a measure of student growth at the individual teacher level. Student growth measures how much a student progresses academically during his or her time with a particular teacher. It takes into…

  4. Measuring irradiation creep

    International Nuclear Information System (INIS)

    Pelah, I.

    1981-03-01

    Simulation of fusion-neutron induced damage by beams of light ions is discussed. It is suggested that accelerated creep measurements to determine ''end of life'' of materials may be done by the application of thermal treatment and thermal creep measurements. (author)

  5. Aerial measurements in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Winkelmann, I.; Thomas, M.; Buchroeder, H.; Brummer, C. [Federal Office for Radiation Protection, Berlin (Germany); Carloff, G. [German Federal Border Police, Grenzschutz-Fliegergruppe, Sankt Augustin (Germany)

    1997-12-31

    Aerial measurements were performed to determine the {sup 137}Cs soil contamination in a given region to detect unknown radiation sources and to assess their activity. For these measurements a computerized gamma ray spectrometer, equipped with a high purity Ge-semiconductor detector and a 12 l volume Nal(Tl)-detector was used. HPGe-detector measurements from different altitudes over area I were done to test and re-calibrate the aerial measuring system. The known {sup 137}Cs contamination of (50.7 {+-} 5.2) kBq m{sup -2} could be confirmed by the measured value of (57 {+-} 10) kBq m{sup -2}. the Nal(Tl)-detector was re-calibrated at that site for further {sup 137}Cs measurements over area II. The area II was surveyed from an altitude of about 70 m and at a parallel line distance of 150 m at an flying speed of 100 km h{sup -1} to determine the {sup 137}Cs soil contamination. The measuring time was two seconds for the Nal(Tl)-detector. For the spectra measured with the HPGe-detector, a measuring time of 30 s each was chosen. From the Nal(Tl)-measurements, a mean {sup 137}Cs value of (60 {+-} 20) kBq m{sup -2} was determined with a maximum value of 90 kBq m{sup -2}. The corresponding values measured by HPGe-detector were (70 {+-} 20) kBq m{sup -2} and 120 kBq m{sup -2}, respectively. For the evaluation of the HPGe-spectra a depth distribution parameter {alpha}/{rho} = (0.44 {+-} 0.21) cm{sup 2} g{sup -1} for {sup 137}Cs was used measured from soil samples. From data measured with the Nal(Tl)-detector during flights over area III, three{sup 60}Co-sources and one {sup 137}Cs source could be detected, localized and their activity assessed. By HPGe-detector measurements, only scattered {sup 192}lr radiation was registered. (au).

  6. Aerial measurements in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Winkelmann, I; Thomas, M; Buchroeder, H; Brummer, C [Federal Office for Radiation Protection, Berlin (Germany); Carloff, G [German Federal Border Police, Grenzschutz-Fliegergruppe, Sankt Augustin (Germany)

    1998-12-31

    Aerial measurements were performed to determine the {sup 137}Cs soil contamination in a given region to detect unknown radiation sources and to assess their activity. For these measurements a computerized gamma ray spectrometer, equipped with a high purity Ge-semiconductor detector and a 12 l volume Nal(Tl)-detector was used. HPGe-detector measurements from different altitudes over area I were done to test and re-calibrate the aerial measuring system. The known {sup 137}Cs contamination of (50.7 {+-} 5.2) kBq m{sup -2} could be confirmed by the measured value of (57 {+-} 10) kBq m{sup -2}. the Nal(Tl)-detector was re-calibrated at that site for further {sup 137}Cs measurements over area II. The area II was surveyed from an altitude of about 70 m and at a parallel line distance of 150 m at an flying speed of 100 km h{sup -1} to determine the {sup 137}Cs soil contamination. The measuring time was two seconds for the Nal(Tl)-detector. For the spectra measured with the HPGe-detector, a measuring time of 30 s each was chosen. From the Nal(Tl)-measurements, a mean {sup 137}Cs value of (60 {+-} 20) kBq m{sup -2} was determined with a maximum value of 90 kBq m{sup -2}. The corresponding values measured by HPGe-detector were (70 {+-} 20) kBq m{sup -2} and 120 kBq m{sup -2}, respectively. For the evaluation of the HPGe-spectra a depth distribution parameter {alpha}/{rho} = (0.44 {+-} 0.21) cm{sup 2} g{sup -1} for {sup 137}Cs was used measured from soil samples. From data measured with the Nal(Tl)-detector during flights over area III, three{sup 60}Co-sources and one {sup 137}Cs source could be detected, localized and their activity assessed. By HPGe-detector measurements, only scattered {sup 192}lr radiation was registered. (au).

  7. Dose measurements in mammography

    International Nuclear Information System (INIS)

    Kainberger, F.; Kallinger, W.

    1977-01-01

    Dose measurements at the mamma during mammography were carried out in the form of direct measurement with thermoluminescent dosimetry. Measurement was done for the in- and outcoming doses at the mamma, the dose exposure of the sternal region and the scattered rays above the symphysis, the latter as parameter for the genetic radiation exposure. As expected, the dose of the smooth radiation used for mammography showed a strong decrease at the outcome point in comparison with the income point. Surprisingly high was the scattered radiation in the sternal region. A corresponding protection by lead plates could be taken into consideration. Extremely low is the scattered radiation above the symphysis. Even measurements with the very sensitive calcium fluoride dosimeters did not reveal any practically important dose in the symphysis region. Most measurement values remained below the determinable dose of 0.3mR. Some maximal values varied in the range of 3-1 mR. (orig.) [de

  8. Solar cell efficiency measurements

    International Nuclear Information System (INIS)

    Ostoja, P.

    1989-01-01

    Solar cells (and solar modules) have to be tested for their performance by means of sound reliable measurement procedures. The need for such measurements arises at various stages of research, of production, and of photovoltaic systems sizing and dimensioning. In fact, accurate measurements are necessary to the researcher, who studies new materials and new processes, to the manufacturer, who has to control his product and, finally, to the user, who needs sound measurements, in order to be in a position to make effective decisions about what kink of product will be needed and with what critical characteristics. In short, standard measurements that allow cells and modules to be characterized serve as a common language, allowing effective communication about products and requirements. 3 refs

  9. Measurement environments and testing

    Science.gov (United States)

    Marvin, A. C.

    1991-06-01

    The various methods used to assess both the emission (interference generation) performance of electronic equipment and the immunity of electronic equipment to external electromagnetic interference are described. The measurement methods attempt to simulate realistic operating conditions for the equipment being tested, yet at the same time they must be repeatable and practical to operate. This has led to the development of a variety of test methods, each of which has its limitations. Concentration is on the most common measurement methods such as open-field test sites, screened enclosures and transverse electromagnetic (TEM) cells. The physical justification for the methods, their limitations, and measurement precision are described. Ways of relating similar measurements made by different methods are discussed, and some thoughts on future measurement improvements are presented.

  10. Standardization of radon measurements

    International Nuclear Information System (INIS)

    Matuszek, J.M.; Hutchinson, J.A.; Lance, B.H.; Virgil, M.G.; Mahoney, R.J.

    1988-01-01

    Radon escaping from soil into homes appears to present the single greatest source of radiation exposure that most people will ever face. Measurement protocols for the relatively inert gas inextricably link the method of collection with the counting of the specimen. The most commonly used methods depend on the measurement of dislocation sites on plastic α-track detectors or on the adsorption of radon onto activated charcoal for subsequent counting of the γ-rays produced by decay of the radon progeny. The uncertainties inherent to the radon-measurement methods used commercially in the United States are far greater than those for measurements of other environmental radionuclides. The results of this preliminary study raise doubts as to whether existing proficiency-testing programs can provide assurance that radon-measurement methods are representative of actual conditions in any dwelling. 17 refs., 1 figs., 4 tabs

  11. Measurement uncertainty and probability

    CERN Document Server

    Willink, Robin

    2013-01-01

    A measurement result is incomplete without a statement of its 'uncertainty' or 'margin of error'. But what does this statement actually tell us? By examining the practical meaning of probability, this book discusses what is meant by a '95 percent interval of measurement uncertainty', and how such an interval can be calculated. The book argues that the concept of an unknown 'target value' is essential if probability is to be used as a tool for evaluating measurement uncertainty. It uses statistical concepts, such as a conditional confidence interval, to present 'extended' classical methods for evaluating measurement uncertainty. The use of the Monte Carlo principle for the simulation of experiments is described. Useful for researchers and graduate students, the book also discusses other philosophies relating to the evaluation of measurement uncertainty. It employs clear notation and language to avoid the confusion that exists in this controversial field of science.

  12. ORDERED WEIGHTED DISTANCE MEASURE

    Institute of Scientific and Technical Information of China (English)

    Zeshui XU; Jian CHEN

    2008-01-01

    The aim of this paper is to develop an ordered weighted distance (OWD) measure, which is thegeneralization of some widely used distance measures, including the normalized Hamming distance, the normalized Euclidean distance, the normalized geometric distance, the max distance, the median distance and the min distance, etc. Moreover, the ordered weighted averaging operator, the generalized ordered weighted aggregation operator, the ordered weighted geometric operator, the averaging operator, the geometric mean operator, the ordered weighted square root operator, the square root operator, the max operator, the median operator and the min operator axe also the special cases of the OWD measure. Some methods depending on the input arguments are given to determine the weights associated with the OWD measure. The prominent characteristic of the OWD measure is that it can relieve (or intensify) the influence of unduly large or unduly small deviations on the aggregation results by assigning them low (or high) weights. This desirable characteristic makes the OWD measure very suitable to be used in many actual fields, including group decision making, medical diagnosis, data mining, and pattern recognition, etc. Finally, based on the OWD measure, we develop a group decision making approach, and illustrate it with a numerical example.

  13. DOAS urban pollution measurements

    International Nuclear Information System (INIS)

    Stevens, R.K.; Vossler, T.L.

    1991-01-01

    This paper reports that during July and August of 1990, a differential optical absorption spectrometer (DOAS) made by OPSIS Inc., was used to measure gaseous air pollutants over three separate open paths in Atlanta, GA. Over path 1 and path 2, ozone (O 3 ), sulfur dioxide (SO 2 ), nitrogen dioxide (NO 2 ), nitrous acid (HNO 2 ), formaldehyde (HCHO), benzene, toluene, and o-xylene were measured. Nitric oxide (NO) and ammonia (NH 3 ) were monitored over path 3 (143 m). The data quality and data capture depended on the compound being measured and the path over which it was measured. Data quality criteria for each compound were chosen such that the average relative standard deviation would be less than 25%. Data capture ranged from 43% for o-xylene for path 1 to 95% for ozone for path 2. Benzene, toluene, and o-xylene concentrations measured over path 2, which crossed over an interstate highway, were higher than concentrations measured over path 1, implicating emissions from vehicles on the highway as a significant source of these compounds. Federal Reference Method (FRM) instruments were located near the DOAS light receivers and measurements of O 3 , NO 2 , and NO were made concurrently with the DOAS. Correlation coefficients greater than 0.85 were obtained between the DOAS and FRM's; however, there was a difference between the mean values obtained by the two methods for O 3 and NO. A gas chromatograph for measuring volatile organic compounds was operated next to the FRM's. Correlation coefficients of about 0.66 were obtained between the DOAS and GC measurements of benzene and o-xylene

  14. Mathematics and Measurement.

    Science.gov (United States)

    Boisvert, R F; Donahue, M J; Lozier, D W; McMichael, R; Rust, B W

    2001-01-01

    In this paper we describe the role that mathematics plays in measurement science at NIST. We first survey the history behind NIST's current work in this area, starting with the NBS Math Tables project of the 1930s. We then provide examples of more recent efforts in the application of mathematics to measurement science, including the solution of ill-posed inverse problems, characterization of the accuracy of software for micromagnetic modeling, and in the development and dissemination of mathematical reference data. Finally, we comment on emerging issues in measurement science to which mathematicians will devote their energies in coming years.

  15. Nuclear lifetime measurement

    International Nuclear Information System (INIS)

    Guillaume, Georges

    Three direct techniques of lifetime measurement are emphasized: electronic methods and two methods based on the Doppler effect (the recoil distance methods or RDM, the Doppler shift attenuation methods or DSAM). Said direct methods are concerned with the direct measurement of the radioactive decay constants of nuclear excited states. They allow lifetimes of nucleus bound states whose deexcitations occur by electromagnetic transitions, to be determined. Other methods for measuring lifetimes are also examined: microwave techniques and those involving the blocking effect in crystals (direct methods) and also various indirect methods of obtaining lifetimes (γ resonance scattering, capture reactions, inelastic electron and nucleus scattering, and Coulomb deexcitation) [fr

  16. Spectroelectrochemical Instrument Measures TOC

    Science.gov (United States)

    Kounaves, Sam

    2011-01-01

    A spectroelectrochemical instrument has been developed for measuring the total organic carbon (TOC) content of an aqueous solution. Measurements of TOC are frequently performed in environmental, clinical, and industrial settings. Until now, techniques for performing such measurements have included, various ly, the use of hazardous reagents, ultraviolet light, or ovens, to promote reactions in which the carbon contents are oxidized. The instrument now being developed is intended to be a safer, more economical means of oxidizing organic carbon and determining the TOC levels of aqueous solutions and for providing a low power/mass unit for use in planetary missions.

  17. Measurement of weak radioactivity

    CERN Document Server

    Theodorsson , P

    1996-01-01

    This book is intended for scientists engaged in the measurement of weak alpha, beta, and gamma active samples; in health physics, environmental control, nuclear geophysics, tracer work, radiocarbon dating etc. It describes the underlying principles of radiation measurement and the detectors used. It also covers the sources of background, analyzes their effect on the detector and discusses economic ways to reduce the background. The most important types of low-level counting systems and the measurement of some of the more important radioisotopes are described here. In cases where more than one type can be used, the selection of the most suitable system is shown.

  18. Measurement of plasma parameters

    International Nuclear Information System (INIS)

    1999-01-01

    The physics issues of the measurements of the plasma properties necessary to provide both the control and science data for achieving the goals of the ITER device are discussed. The assessment of the requirements for these measurements is first discussed, together with priorities that relate to the experimental program. Subsequently, some of the proposed measurement techniques, the plasma diagnostics, are described with particular emphasis on their implementation on ITER and their capability to meet the requirements. A judgement on the present status of the diagnostic program on ITER is provided with some indication of the research and development program necessary to demonstrate viability of techniques or their implementation. (author)

  19. Measurements of smoke

    International Nuclear Information System (INIS)

    Bakker, F.P.; Geusebroek, M.; Kos, G.P.A.; Van Egmond, B.F.

    2005-02-01

    For Euromate measurements are performed at 21 December 2004, in order to characterize their new smoking chamber 'rookabri S+G2'. At location gas analysis and particle measurements are performed. A number of off-line sampled organic smoke trace compounds were analysed at our laboratory. Sampling and measurements were performed at different smoke levels with 0, 2, 4 and 6 smoking volunteers. The smoke-abri is a specially designed space for smokers in which the environment is cleared from tobacco smoke and odor [nl

  20. Refractive index based measurements

    DEFF Research Database (Denmark)

    2014-01-01

    In a method for performing a refractive index based measurement of a property of a fluid such as chemical composition or temperature by observing an apparent angular shift in an interference fringe pattern produced by back or forward scattering interferometry, ambiguities in the measurement caused...... by the apparent shift being consistent with one of a number of numerical possibilities for the real shift which differ by 2n are resolved by combining measurements performed on the same sample using light paths therethrough of differing lengths....

  1. Cardiac output measurement

    Directory of Open Access Journals (Sweden)

    Andreja Möller Petrun

    2014-02-01

    Full Text Available In recent years, developments in the measuring of cardiac output and other haemodynamic variables are focused on the so-called minimally invasive methods. The aim of these methods is to simplify the management of high-risk and haemodynamically unstable patients. Due to the need of invasive approach and the possibility of serious complications the use of pulmonary artery catheter has decreased. This article describes the methods for measuring cardiac output, which are based on volume measurement (Fick method, indicator dilution method, pulse wave analysis, Doppler effect, and electrical bioimpedance.

  2. RF impedance measurement calibration

    International Nuclear Information System (INIS)

    Matthews, P.J.; Song, J.J.

    1993-01-01

    The intent of this note is not to explain all of the available calibration methods in detail. Instead, we will focus on the calibration methods of interest for RF impedance coupling measurements and attempt to explain: (1). The standards and measurements necessary for the various calibration techniques. (2). The advantages and disadvantages of each technique. (3). The mathematical manipulations that need to be applied to the measured standards and devices. (4). An outline of the steps needed for writing a calibration routine that operated from a remote computer. For further details of the various techniques presented in this note, the reader should consult the references

  3. Parameter measurement of target

    International Nuclear Information System (INIS)

    Gao Dangzhong

    2001-01-01

    The progress of parameter measurement of target (ICF-15) in 1999 are presented, including the design and contract of the microsphere equator profiler, the precise air bearing manufacturing, high-resolution X-ray image of multi-layer shells and the X-ray photos processed with special image and data software, some plastic shells measured in precision of 0.3 μm, the high-resolution observation and photograph system of 'dew-point method', special fixture of target and its temperature distribution measuring, the dew-point temperature and fuel gas pressure of shells measuring with internal pressure of 5 - 15 (x10 5 ) Pa D 2 and wall thickness of 1.5∼3 μm

  4. Bioelectric Signal Measuring System

    Science.gov (United States)

    Guadarrama-Santana, A.; Pólo-Parada, L.; García-Valenzuela, A.

    2015-01-01

    We describe a low noise measuring system based on interdigitated electrodes for sensing bioelectrical signals. The system registers differential voltage measurements in order of microvolts. The base noise during measurements was in nanovolts and thus, the sensing signals presented a very good signal to noise ratio. An excitation voltage of 1Vrms with 10 KHz frequency was applied to an interdigitated capacitive sensor without a material under test and to a mirror device simultaneously. The output signals of both devices was then subtracted in order to obtain an initial reference value near cero volts and reduce parasitic capacitances due to the electronics, wiring and system hardware as well. The response of the measuring system was characterized by monitoring temporal bioelectrical signals in real time of biological materials such as embryo chicken heart cells and bovine suprarenal gland cells.

  5. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... using relative intensity, people pay attention to how physical activity affects their heart rate and breathing. The talk test is a simple way to measure relative intensity. ...

  6. Measuring Entrepreneurial Ecosystems

    NARCIS (Netherlands)

    Stam, F.C.

    How can entrepreneurial ecosystems and productive entrepreneurship can be traced empirically and how is entrepreneurship related to entrepreneurial ecosystems. The analyses in this chapter show the value of taking a systems view on the context of entrepreneurship. We measure entrepreneurial

  7. Dilepton Measurements with CERES

    Energy Technology Data Exchange (ETDEWEB)

    Marin,A.; Rehak, P. et al.

    2007-07-09

    We report on dilepton measurements for central Pb on Au collisions at the top CERN SPS energy with the upgraded CERES experiment. The dilepton mass spectrum of 2000 data with improved mass resolution shows an enhancement over the expectation from hadron decays that is well described by a model including a strong broadening of the {rho} spectral function. The measured excess yield excludes the dropping mass scenario. We also report on the {phi} meson measured simultaneously both in the K{sup +}K{sup -} and in the dilepton decay channel for the first time in high energy heavy-ion collisions. An excellent agreement is found between the rapidity densities and the shape of the measured transverse momentum spectrum. The data rule out a possible enhancement of the {phi} yield in the leptonic over hadronic channel by a factor larger than 1.6 at 95% CL. CERES results are in agreement with NA49 results.

  8. Measure Evaluation Dataverse

    Data.gov (United States)

    US Agency for International Development — The MEASURE Evaluation Dataverse is a collection of innovative evaluation data sets assembled in order to increase the evidence-base on program impact and evaluate...

  9. Littoral Measurements Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Barny units measure ocean currents and sea surface heights on continental shelves and in ocean straits. SEPTR units are similar to Barnys but also record...

  10. Measurement of leached hulls

    International Nuclear Information System (INIS)

    Reilly, T.D.

    1979-07-01

    Leached hulls are the short lengths of fuel rod cladding and fuel element hardware which constitute a major waste product of a reprocessing plant employing a chop-and-leach head-end process. The small, undissolved fuel residue (0.1 to 1.0% of original fuel content) which is discarded with this waste must be measured for safeguards, material accountability, and process control reasons. This report gives a critical analysis of hull measurement techniques involving the analysis of fission product gamma rays, spontaneous fission neutrons from curium, and delayed neutron activation. Major emphasis is given to the measurement of 2186-keV gamma rays from 144 Ce-- 144 Pr. A detailed description of typical leached hull characteristics is presented at the beginning of the report. An extensive review of experience gained from existing hull measurement systems in the United Kingdom, France, Japan, Germany, Italy, and the United States is presented

  11. Statistical Measures of Marksmanship

    National Research Council Canada - National Science Library

    Johnson, Richard

    2001-01-01

    .... This report describes objective statistical procedures to measure both rifle marksmanship accuracy, the proximity of an array of shots to the center of mass of a target, and marksmanship precision...

  12. Pulse holographic measurement techniques

    International Nuclear Information System (INIS)

    Kim, Cheol Jung; Baik, Seong Hoon; Hong, Seok Kyung; Kim, Jeong Moog; Kim, Duk Hyun

    1992-01-01

    With the development of laser, remote inspection techniques using laser have been growing on. The inspection and measurement techniques by pulse holography are well-established technique for precise measurement, and widely used in various fields of industry now. In nuclear industry, this technology is practically used because holographic inspection is remote, noncontact, and precise measurement technique. In relation to remote inspection technology in nuclear industry, state-of-the art of pulse HNDT (Holographic non-destructive testing) and holographic measurement techniques are examined. First of all, the fundamental principles as well as practical problems for applications are briefly described. The fields of pulse holography have been divided into the HNDT, flow visualization and distribution study, and other application techniques. Additionally holographic particle study, bubble chamber holography, and applications to other visualization techniques are described. Lastly, the current status for the researches and applications of pulse holography to nuclear industry which are carried out actively in Europe and USA, is described. (Author)

  13. Measurement theory for engineers

    CERN Document Server

    Gertsbakh, Ilya

    2003-01-01

    The emphasis of this textbook is on industrial applications of Statistical Measurement Theory. It deals with the principal issues of measurement theory, is concise and intelligibly written, and to a wide extent self-contained. Difficult theoretical issues are separated from the mainstream presentation. Each topic starts with an informal introduction followed by an example, the rigorous problem formulation, solution method, and a detailed numerical solution. Each chapter concludes with a set of exercises of increasing difficulty, mostly with solutions. The book is meant as a text for graduate students and a reference for researchers and industrial experts specializing in measurement and measurement data analysis for quality control, quality engineering and industrial process improvement using statistical methods. Knowledge of calculus and fundamental probability and statistics is required for the understanding of its contents.

  14. Measuring Agricultural Bias

    DEFF Research Database (Denmark)

    Jensen, Henning Tarp; Robinson, Sherman; Tarp, Finn

    The measurement issue is the key issue in the literature on trade policy-induced agri-cultural price incentive bias. This paper introduces a general equilibrium effective rate of protection (GE-ERP) measure, which extends and generalizes earlier partial equilibrium nominal protection measures...... shares and intersectoral linkages - are crucial for determining the sign and magnitude of trade policy bias. The GE-ERP measure is therefore uniquely suited to capture the full impact of trade policies on agricultural price incentives. A Monte Carlo procedure confirms that the results are robust....... For the 15 sample countries, the results indicate that the agricultural price incentive bias, which was generally perceived to exist during the 1980s, was largely eliminated during the 1990s. The results also demonstrate that general equilibrium effects and country-specific characteristics - including trade...

  15. Environmental Measurements and Modeling

    Science.gov (United States)

    Environmental measurement is any data collection activity involving the assessment of chemical, physical, or biological factors in the environment which affect human health. Learn more about these programs and tools that aid in environmental decisions

  16. Polar measurements on profiles

    Energy Technology Data Exchange (ETDEWEB)

    Althaus, D.

    1985-03-01

    Wind tunnel models with a profile depth of t=0.5 m were measured in a laminar wind tunnel by the usual measuring processes. The profile resistance was determined by integration along the width of span. The smooth profiles were examined at Re=0.7/1.0 and 1.5 million. At Re=1.0 million, the position of the changeover points were determined with a stethoscope. Also at this Reynolds number measurements were taken with a trip wire of d=2 mm diameter, directly on the profile nose. The tables contain the co-ordinates of the profiles, the contours, the theoretical speed distributions for 4 different angles of attack, the csub(a)-csub(w) polar measurements and changeover points, and the torque coefficients around the t/4 point. (BR).

  17. Acceleration measurements in JEM

    International Nuclear Information System (INIS)

    Ikeda, Toshitami; Murakami, Keiji

    2000-01-01

    Since summer in 1996, National Space Development Agency of Japan (NASDA) has continued a concept study for a microgravity measurement apparatus (MMA) to be installed in the Japanese Experiment Module (JEM). The concept study was finished in 1998, and then we have been proceeding for a basic design. For experiments conducted with some of NASDA payloads in JEM-PM (Pressurized Module), measuring detailed microgravity environment was required. In addition, experiments to be performed with payload equipment attached on the JEM-EF (Exposed Facility) are requiring for obtaining the microgravity measurement data. Thus, we are adding some modification to the concept design of MMA in order to make the common hardware available for measurement of both environment in the JEM-PM and that of the JEM-EF. In this paper, the current development status of Japanese payloads and the modified concept of the MMA are introduced

  18. Essentials of measure theory

    CERN Document Server

    Kubrusly, Carlos S

    2015-01-01

    Classical in its approach, this textbook is thoughtfully designed and composed in two parts. Part I is meant for a one-semester beginning graduate course in measure theory, proposing an “abstract” approach to measure and integration, where the classical concrete cases of Lebesgue measure and Lebesgue integral are presented as an important particular case of general theory. Part II of the text is more advanced and is addressed to a more experienced reader. The material is designed to cover another one-semester graduate course subsequent to a first course, dealing with measure and integration in topological spaces. The final section of each chapter in Part I presents problems that are integral to each chapter, the majority of which consist of auxiliary results, extensions of the theory, examples, and counterexamples. Problems which are highly theoretical have accompanying hints. The last section of each chapter of Part II consists of Additional Propositions containing auxiliary and complementary results. Th...

  19. Control Measure Dataset

    Data.gov (United States)

    U.S. Environmental Protection Agency — The EPA Control Measure Dataset is a collection of documents describing air pollution control available to regulated facilities for the control and abatement of air...

  20. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Local Programs Measuring Physical Activity Intensity Recommend on Facebook Tweet Share Compartir For more help with what ... RSS ABOUT About CDC Jobs Funding LEGAL Policies Privacy FOIA No Fear Act OIG 1600 Clifton Road ...

  1. Gas flowrate measurements

    International Nuclear Information System (INIS)

    Boure, Madeleine.

    1978-05-01

    The main types of gas flowmeters, especially those which are used for laboratory measurements are reviewed. Modeling, design recommendations, calibration methods and expected accuracy are discussed for each flowmeter. Different types and trademarks are given in two tables [fr

  2. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Compartir For more help with what counts as aerobic activity, watch this video: Windows Media Player, 4: ... ways to understand and measure the intensity of aerobic activity: relative intensity and absolute intensity. Relative Intensity ...

  3. Soliton microcomb range measurement

    Science.gov (United States)

    Suh, Myoung-Gyun; Vahala, Kerry J.

    2018-02-01

    Laser-based range measurement systems are important in many application areas, including autonomous vehicles, robotics, manufacturing, formation flying of satellites, and basic science. Coherent laser ranging systems using dual-frequency combs provide an unprecedented combination of long range, high precision, and fast update rate. We report dual-comb distance measurement using chip-based soliton microcombs. A single pump laser was used to generate dual-frequency combs within a single microresonator as counterpropagating solitons. We demonstrated time-of-flight measurement with 200-nanometer precision at an averaging time of 500 milliseconds within a range ambiguity of 16 millimeters. Measurements at distances up to 25 meters with much lower precision were also performed. Our chip-based source is an important step toward miniature dual-comb laser ranging systems that are suitable for photonic integration.

  4. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Physical Activity Basics Needs for Adults Needs for Children What Counts Needs for Older Adults Needs for ... Adding Physical Activity to Your Life Activities for Children Activities for Older Adults Overcoming Barriers Measuring Physical ...

  5. Measuring what's missing

    DEFF Research Database (Denmark)

    Jones, Edward Samuel

    2016-01-01

    mass. Using the UNDP's Human Development Index, the empirical performance of such coverage metrics are compared to alternative measures of convergence. The former are advantageous -- they provide probabilistic estimates of simulation coverage and permit calculation of strict bounds on estimates...

  6. Wearable 3D measurement

    Science.gov (United States)

    Manabe, Yoshitsugu; Imura, Masataka; Tsuchiya, Masanobu; Yasumuro, Yoshihiro; Chihara, Kunihiro

    2003-01-01

    Wearable 3D measurement realizes to acquire 3D information of an objects or an environment using a wearable computer. Recently, we can send voice and sound as well as pictures by mobile phone in Japan. Moreover it will become easy to capture and send data of short movie by it. On the other hand, the computers become compact and high performance. And it can easy connect to Internet by wireless LAN. Near future, we can use the wearable computer always and everywhere. So we will be able to send the three-dimensional data that is measured by wearable computer as a next new data. This paper proposes the measurement method and system of three-dimensional data of an object with the using of wearable computer. This method uses slit light projection for 3D measurement and user"s motion instead of scanning system.

  7. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Adults Need More Physical Activity MMWR Data Highlights State Indicator Report on Physical Activity, 2014 Recommendations & Guidelines ... Activity Overweight & Obesity Healthy Weight Breastfeeding Micronutrient Malnutrition State and Local Programs Measuring Physical Activity Intensity Recommend ...

  8. Measuring multifactor productivity growth

    Czech Academy of Sciences Publication Activity Database

    Wölfl, A.; Hájková, Dana

    -, 2007/5 (2007), s. 1-45 Institutional research plan: CEZ:AV0Z70850503 Keywords : multifactor productivity growth * GDP growth * measuring Subject RIV: AH - Economics http://www.oecd.org/dataoecd/61/17/39522985.pdf

  9. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... 10 miles per hour or faster Jumping rope Heavy gardening (continuous digging or hoeing) Hiking uphill or with a heavy backpack Other Methods of Measuring Intensity Target Heart ...

  10. Health System Measurement Project

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Health System Measurement Project tracks government data on critical U.S. health system indicators. The website presents national trend data as well as detailed...

  11. Uncertainty and measurement

    International Nuclear Information System (INIS)

    Landsberg, P.T.

    1990-01-01

    This paper explores how the quantum mechanics uncertainty relation can be considered to result from measurements. A distinction is drawn between the uncertainties obtained by scrutinising experiments and the standard deviation type of uncertainty definition used in quantum formalism. (UK)

  12. Improvement by GQM measurement

    NARCIS (Netherlands)

    Solingen, van D.M.; Veenendaal, van E.P.W.M.; Trienekens, J.; Veenendaal, van E.

    1997-01-01

    Software development is a discipline with specific management difficulties. Collecting relevant data during development is a way to overcome these difficulties. Such data collectionfor software development is termed ‘Software Measurement’. Software measurement is a poweiful aid to quality

  13. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Adults Needs for Children What Counts Needs for Older Adults Needs for Pregnant or Postpartum Women Physical Activity & ... to Your Life Activities for Children Activities for Older Adults Overcoming Barriers Measuring Physical Activity Intensity Target Heart ...

  14. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Hiking uphill or with a heavy backpack Other Methods of Measuring Intensity Target Heart Rate and Estimated ... Help: How do I view different file formats (PDF, DOC, PPT, MPEG) on this site? Adobe PDF ...

  15. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Hiking uphill or with a heavy backpack Other Methods of Measuring Intensity Target Heart Rate and Estimated ... YouTube Instagram Listen Watch RSS ABOUT About CDC Jobs Funding LEGAL Policies Privacy FOIA No Fear Act ...

  16. Performance Measurement at Universities

    DEFF Research Database (Denmark)

    Lueg, Klarissa

    2014-01-01

    This paper proposes empirical approaches to testing the reliability, validity, and organizational effectiveness of student evaluations of teaching (SET) as a performance measurement instrument in knowledge management at the institutional level of universities. Departing from Weber’s concept...

  17. Measuring Physical Activity Intensity

    Medline Plus

    Full Text Available ... Measuring Intensity Target Heart Rate and Estimated Maximum Heart Rate Perceived Exertion (Borg Rating of Perceived Exertion Scale) Get Email Updates To receive email updates about this page, enter your email ... ...

  18. Dilepton measurements with CERES

    CERN Document Server

    Marin, A; Agakichiev, G; Andronic, A; Antonczyk, D; Appelshäuser, H; Bielcíkováe, V; Biel, J; Braun-Munzinger, P; Busch, O; Cherlin, A; Damjanovic, S; Dietel, T; Dietrich, L; Drees, A; Esumi, S I; Filimonov, K; Fomenko, K; Fraenkel, Zeev; Garabatos, C; Glässel, P; Hering, G; Holeczek, J; Kalisky, M; Kniege, S; Kushpil, V; Ludolphs, W; Maas, A; Milosevic, J; Miskowiec, D; Ortega, R; Panebratsev, Yu A; Petchenova, O; Petracek, V; Ploskon, M; Radomski, S; Rak, J; Ravinovich, I; Rehak, P; Sako, H; Schmitz, W; Schuchmann, S; Sedykh, S; Shimansky, S; Soualah, R; Stachel, J; Sumbera, M; Tilsner, H; Tserruya, Itzhak; Tsiledakis, G; Wessels, J P; Wienold, T; Wurm, J P; Yurevich, S; Yurevich, V

    2008-01-01

    We report on dilepton measurements for central Pb on Au collisions at the top CERN SPS energy with the upgraded CERES experiment. The dilepton mass spectrum of 2000 data with improved mass resolution shows an enhancement over the expectation from hadron decays that is well described by a model including a strong broadening of the $\\rho$ spectral function. The measured excess yield excludes the dropping mass scenario. We also report on the $\\phi$ meson measured simultaneously both in the $K^+K^-$ and in the dilepton decay channel for the first time in high energy heavy-ion collisions. An excellent agreement is found between the rapidity densities and the shape of the measured tranverse momentum spectrum. The data rule out a possible enhancement of the $\\phi$ yield in the leptonic over hadronic channel by a factor larger than 1.6 at 95% CL. CERES results are in agreement with NA49 results.

  19. Theory of Effectiveness Measurement

    National Research Council Canada - National Science Library

    Bullock, Richard K

    2006-01-01

    Effectiveness measures provide decision makers feedback on the impact of deliberate actions and affect critical issues such as allocation of scarce resources, as well as whether to maintain or change existing strategy...

  20. Photovoltaic spectral responsivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Emery, K.; Dunlavy, D.; Field, H.; Moriarty, T. [National Renewable Energy Lab., Golden, CO (United States)

    1998-09-01

    This paper discusses the various elemental random and nonrandom error sources in typical spectral responsivity measurement systems. The authors focus specifically on the filter and grating monochrometer-based spectral responsivity measurement systems used by the Photovoltaic (PV) performance characterization team at NREL. A variety of subtle measurement errors can occur that arise from a finite photo-current response time, bandwidth of the monochromatic light, waveform of the monochromatic light, and spatial uniformity of the monochromatic and bias lights; the errors depend on the light source, PV technology, and measurement system. The quantum efficiency can be a function of he voltage bias, light bias level, and, for some structures, the spectral content of the bias light or location on the PV device. This paper compares the advantages and problems associated with semiconductor-detector-based calibrations and pyroelectric-detector-based calibrations. Different current-to-voltage conversion and ac photo-current detection strategies employed at NREL are compared and contrasted.

  1. Nuclear measurements in industry

    International Nuclear Information System (INIS)

    Rozsa, S.

    1989-01-01

    In this book the author provides a description of nuclear measurements in industry, covering the physical principles, methods, instruments and equipment, and industrial applications. One of the great advantages of industrial nuclear measurements is that their use ensures the optimum use of raw material. The increasing cost of raw materials makes it essential to adhere strictly to the standards and prescriptions related to the product and this is possible only by the application of continuous and accurate measurements. As a result, the importance of nuclear instruments is rapidly growing particularly in fields where the application of alternative methods is not possible. This is illustrated by several practical examples described in the book. Similarly important are nuclear measuring the process control equipment which serve to optimize the use of energy in industrial processes

  2. Wake field measurements

    International Nuclear Information System (INIS)

    Palumbo, L.

    1989-01-01

    In this paper the concept of Wakefields and Machine Impedance are introduced. Several measurements technique of these quantities either in the laboratory before installation or from beam observation are presented

  3. Tomographic multiphase flow measurement

    International Nuclear Information System (INIS)

    Sætre, C.; Johansen, G.A.; Tjugum, S.A.

    2012-01-01

    Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain (). These are related to reducing measurement uncertainties arising from variations in the flow regime, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. This work focuses on the first two issues using multi gamma beam (MGB) measurements for identification of the type of flow regime. Further gamma ray tomographic measurements are used for reference of the gas/liquid distribution. For the MGB method one Am-241 source with principal emission at 59.5 keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second is positioned to the side so that this beam is close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the flow pattern, i.e. the instantaneous cross-sectional gas-liquid distribution. The measurement setup also includes Compton scattering measurements, which can provide information about the changes in the water salinity for flow segments with high water liquid ratio and low gas fractions. By measuring the transmitted intensity in short time slots (<100ms), rapid regime variations are revealed. From this we can select the time sections suitable for salinity measurements. Since the salinity variations change at the time scale of hours, a running average can be performed to increase the accuracy of the measurements. Recent results of this work will be presented here. - Highlights: ► Multiphase flow gas-fraction and flow regime measurements by multi gamma ray beams. ► High-speed gamma ray tomograph as reference for the flow pattern and gas fraction. ► Dual modality

  4. Tomographic multiphase flow measurement

    Energy Technology Data Exchange (ETDEWEB)

    Saetre, C., E-mail: camilla@ift.uib.no [Department of Physics and Technology, University of Bergen (Norway); Michelsen Centre for Industrial Measurement Science and Technology (Norway); Johansen, G.A. [Department of Physics and Technology, University of Bergen (Norway); Michelsen Centre for Industrial Measurement Science and Technology (Norway); Tjugum, S.A. [Michelsen Centre for Industrial Measurement Science and Technology (Norway); Roxar Flow Measurement, Bergen (Norway)

    2012-07-15

    Measurement of multiphase flow of gas, oil and water is not at all trivial and in spite of considerable achievements over the past two decades, important challenges remain (). These are related to reducing measurement uncertainties arising from variations in the flow regime, improving long term stability and developing new means for calibration, adjustment and verification of the multiphase flow meters. This work focuses on the first two issues using multi gamma beam (MGB) measurements for identification of the type of flow regime. Further gamma ray tomographic measurements are used for reference of the gas/liquid distribution. For the MGB method one Am-241 source with principal emission at 59.5 keV is used because this relatively low energy enables efficient collimation and thereby shaping of the beams, as well as compact detectors. One detector is placed diametrically opposite the source whereas the second is positioned to the side so that this beam is close to the pipe wall. The principle is then straight forward to compare the measured intensities of these detectors and through that identify the flow pattern, i.e. the instantaneous cross-sectional gas-liquid distribution. The measurement setup also includes Compton scattering measurements, which can provide information about the changes in the water salinity for flow segments with high water liquid ratio and low gas fractions. By measuring the transmitted intensity in short time slots (<100ms), rapid regime variations are revealed. From this we can select the time sections suitable for salinity measurements. Since the salinity variations change at the time scale of hours, a running average can be performed to increase the accuracy of the measurements. Recent results of this work will be presented here. - Highlights: Black-Right-Pointing-Pointer Multiphase flow gas-fraction and flow regime measurements by multi gamma ray beams. Black-Right-Pointing-Pointer High-speed gamma ray tomograph as reference for the flow

  5. Measuring Entrepreneurial Ecosystems

    OpenAIRE

    Stam, F.C.

    2017-01-01

    How can entrepreneurial ecosystems and productive entrepreneurship can be traced empirically and how is entrepreneurship related to entrepreneurial ecosystems. The analyses in this chapter show the value of taking a systems view on the context of entrepreneurship. We measure entrepreneurial ecosystem elements and use these to compose an entrepreneurial ecosystem index. Next, we measure the output of entrepreneurial ecosystems with different indicators of high-growth firms. We use the 12 provi...

  6. Safeguards and physics measurements

    Energy Technology Data Exchange (ETDEWEB)

    Carchon, R

    2002-04-01

    SCK-CEN's programme on safeguards and physics measurements involves gamma and neutron dosimetry, calibrations and irradiations, electronic support, metrology of various samples including internal contamination of human beings, of waste barrels and of fissile materials, neutron activation analysis, and radioisotope source preparation. The document reports on the main activities and achievements of the sections 'Instrumentation, Calibration and Dosimetry' and 'Safeguards and Nuclear Physics Measurements'.

  7. Lebesgue measure and gambling

    International Nuclear Information System (INIS)

    Kanovei, V G; Linton, Tom; Uspensky, Vladimir A

    2008-01-01

    Lebesgue measure of point sets is characterized in terms of the existence of various strategies in a certain coin-flipping game. 'Rational' and 'discrete' modifications of this game are investigated. We prove that if one of the players has a winning strategy in a game of this type depending on a given set P subset or equal [0,1], then this set is measurable. Bibliography: 11 titles.

  8. Lebesgue measure and gambling

    Science.gov (United States)

    Kanoveĭ, V. G.; Linton, Tom; Uspensky, Vladimir A.

    2008-12-01

    Lebesgue measure of point sets is characterized in terms of the existence of various strategies in a certain coin-flipping game. 'Rational' and 'discrete' modifications of this game are investigated. We prove that if one of the players has a winning strategy in a game of this type depending on a given set P\\subseteq \\lbrack 0,1 \\rbrack , then this set is measurable. Bibliography: 11 titles.

  9. Modulated Current Drive Measurements

    International Nuclear Information System (INIS)

    Petty, C.C.; Lohr, J.; Luce, T.C.; Prater, R.; Cox, W.A.; Forest, C.B.; Jayakumar, R.J.; Makowski, M.A.

    2005-01-01

    A new measurement approach is presented which directly determines the noninductive current profile from the periodic response of the motional Stark effect (MSE) signals to the slow modulation of the external current drive source. A Fourier transform of the poloidal magnetic flux diffusion equation is used to analyze the MSE data. An example of this measurement technique is shown using modulated electron cyclotron current drive (ECCD) discharges from the DIII-D tokamak

  10. Measurement of optical glasses

    International Nuclear Information System (INIS)

    Nicolau-Rebigan, S.

    1978-11-01

    The possibilities of measurement of the optical glasses parameters needed in building optical devices especially in lasers devices are presented. In the first chapter the general features of the main optical glasses as well as the modalities of obtaining them are given. Chapter two defines the optical glass parameters, and the third chapter describes the measuring methods of the optical glass parameters. Finally, the conclusions which point out the utilization of this paper are presented. (author)

  11. Measuring fluid pressure

    International Nuclear Information System (INIS)

    Lee, A.S.

    1978-01-01

    A method and apparatus are described for measuring the pressure of a fluid having characteristics that make it unsuitable for connection directly to a pressure gauge. The method is particularly suitable for the periodic measurement of the pressure of a supply of liquid Na to Na-lubricated bearings of pumps for pumping Na from a reservoir to the bearing via a filter, the reservoir being contained in a closed vessel containing an inert blanket gas, such as Ar, above the Na. (UK)

  12. Radiation dose measurements

    International Nuclear Information System (INIS)

    1960-01-01

    About 200 scientists from 28 countries and 5 international organizations met at a symposium on radiation dosimetry held by the International Atomic Energy Agency in June 1960. The aim of the symposium was not so much the description of a large number of measuring instruments as a discussion of the methods used, with special emphasis on those problems which had become important in the context of recent developments, such as the measurement of mixed or very large doses

  13. Temperature measurement and control

    CERN Document Server

    Leigh, JR

    1988-01-01

    This book treats the theory and practice of temperature measurement and control and important related topics such as energy management and air pollution. There are no specific prerequisites for the book although a knowledge of elementary control theory could be useful. The first half of the book is an application oriented survey of temperature measurement techniques and devices. The second half is concerned mainly with temperature control in both simple and complex situations.

  14. Safeguards and physics measurements

    International Nuclear Information System (INIS)

    Carchon, R.

    2002-01-01

    SCK-CEN's programme on safeguards and physics measurements involves gamma and neutron dosimetry, calibrations and irradiations, electronic support, metrology of various samples including internal contamination of human beings, of waste barrels and of fissile materials, neutron activation analysis, and radioisotope source preparation. The document reports on the main activities and achievements of the sections 'Instrumentation, Calibration and Dosimetry' and 'Safeguards and Nuclear Physics Measurements'

  15. 4. Measuring technique

    International Nuclear Information System (INIS)

    2006-01-01

    It is noted that in nuclear medicine a most widely the scintillation detectors are applying. Action of these detectors is based on registration of light flares in visible and ultraviolet field arising in scintillator under ionizing radiation action. In the chapter following subchapters are included: gamma-spectrometer and gamma radiation detectors; counter of whole body; measuring of accumulated activity (uptake measurements); scanner; scintillation chamber; single-photon emission computed tomography; positron emission computed tomography; magnet resonance tomography; computer technique, images making

  16. Soil conservation measures: exercises

    OpenAIRE

    Figueiredo, Tomás de; Fonseca, Felícia

    2009-01-01

    Exercises proposed under the topic of Soil Conservation Measures addresses to the design of structural measure, namely waterways in the context of a soil conservation plan. However, to get a better insight on the actual meaning of soil loss as a resource loss, a prior exercise is proposed to students. It concerns calculations of soil loss due to sheet (interrill) erosion and to gully erosion, and allows the perception through realistic number of the impact of these mechanism...

  17. Thermal power measurement apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Thermal power measurements are important in nuclear power plants, fossil-fuel plants and other closed loop systems such as heat exchangers and chemical reactors. The main object of this invention is to determine the enthalpy of a fluid using only acoustically determined sound speed and correlating the speed with enthalpy. An enthalpy change is measured between two points in the fluid flow: the apparatus is described in detail. (U.K.)

  18. Pressure Measurement Systems

    Science.gov (United States)

    1990-01-01

    System 8400 is an advanced system for measurement of gas and liquid pressure, along with a variety of other parameters, including voltage, frequency and digital inputs. System 8400 offers exceptionally high speed data acquisition through parallel processing, and its modular design allows expansion from a relatively inexpensive entry level system by the addition of modular Input Units that can be installed or removed in minutes. Douglas Juanarena was on the team of engineers that developed a new technology known as ESP (electronically scanned pressure). The Langley ESP measurement system was based on miniature integrated circuit pressure-sensing transducers that communicated pressure information to a minicomputer. In 1977, Juanarena formed PSI to exploit the NASA technology. In 1978 he left Langley, obtained a NASA license for the technology, introduced the first commercial product, the 780B pressure measurement system. PSI developed a pressure scanner for automation of industrial processes. Now in its second design generation, the DPT-6400 is capable of making 2,000 measurements a second and has 64 channels by addition of slave units. New system 8400 represents PSI's bid to further exploit the 600 million U.S. industrial pressure measurement market. It is geared to provide a turnkey solution to physical measurement.

  19. Precision lifetime measurements

    International Nuclear Information System (INIS)

    Tanner, C.E.

    1994-01-01

    Precision measurements of atomic lifetimes provide important information necessary for testing atomic theory. The authors employ resonant laser excitation of a fast atomic beam to measure excited state lifetimes by observing the decay-in-flight of the emitted fluorescence. A similar technique was used by Gaupp, et al., who reported measurements with precisions of less than 0.2%. Their program includes lifetime measurements of the low lying p states in alkali and alkali like systems. Motivation for this work comes from a need to test the atomic many-body-perturbation theory (MBPT) that is necessary for interpretation of parity nonconservation experiments in atomic cesium. The authors have measured the cesium 6p 2 P 1/2 and 6p 2 P 3/2 state lifetimes to be 34.934±0.094 ns and 30.499±0.070 ns respectively. With minor changes to the apparatus, they have extended their measurements to include the lithium 2p 2 P 1/2 and 2p 2 P 3/2 states

  20. Measurement quality assurance

    International Nuclear Information System (INIS)

    Eisenhower, E.H.

    1988-01-01

    The quality of a radiation protection program can be no better than the quality of the measurements made to support it. In many cases, that quality is unknown and is merely implied on the basis of a calibration of a measuring instrument. If that calibration is inappropriate or is performed improperly, the measurement result will be inaccurate and misleading. Assurance of measurement quality can be achieved if appropriate procedures are followed, including periodic quality control actions that demonstrate adequate performance. Several national measurement quality assurance (MQA) programs are operational or under development in specific areas. They employ secondary standards laboratories that provide a high-quality link between the National Bureau of Standards and measurements made at the field use level. The procedures followed by these secondary laboratories to achieve MQA will be described, as well as plans for similar future programs. A growing general national interest in quality assurance, combined with strong specific motivations for MQA in the area of ionizing radiation, will provide continued demand for appropriate national programs. Such programs must, however, employ procedures that are cost effective and must be developed with participation by all affected parties

  1. Critique of protective measurements

    International Nuclear Information System (INIS)

    Hari Dass, N.D.; Qureshi, T.

    1999-01-01

    The recently proposed idea of open-quotes protectiveclose quotes measurement of a quantum state is critically examined, and generalized. Earlier criticisms of the idea are discussed, and their relevance to the proposal assessed. Several constraints on measuring apparatus required by open-quotes protectiveclose quotes measurements are discussed, with emphasis on how they may restrict their experimental feasibility. Though open-quotes protectiveclose quotes measurements result in an unchanged system state and a shift of the pointer proportional to the expectation value of the measured observable in the system state, the actual reading of the pointer position gives rise to several subtleties. We propose several schemes for reading the pointer position, both when the apparatus is treated as a classical system as well as when its quantum aspects are taken into account, that address these issues. The tiny entanglement which is always present due to deviation from extreme adiabaticity in realistic situations is argued to be the weakest aspect of the proposal. Because of this, one can never perform a protective measurement on a single quantum system with absolute certainty. This clearly precludes an ontological status for the wave function. Several other conceptual issues are also discussed. copyright 1999 The American Physical Society

  2. Measure problem in cosmology

    International Nuclear Information System (INIS)

    Gibbons, G. W.; Turok, Neil

    2008-01-01

    The Hamiltonian structure of general relativity provides a natural canonical measure on the space of all classical universes, i.e., the multiverse. We review this construction and show how one can visualize the measure in terms of a 'magnetic flux' of solutions through phase space. Previous studies identified a divergence in the measure, which we observe to be due to the dilatation invariance of flat Friedmann-Lemaitre-Robertson-Walker universes. We show that the divergence is removed if we identify universes which are so flat they cannot be observationally distinguished. The resulting measure is independent of time and of the choice of coordinates on the space of fields. We further show that, for some quantities of interest, the measure is very insensitive to the details of how the identification is made. One such quantity is the probability of inflation in simple scalar field models. We find that, according to our implementation of the canonical measure, the probability for N e-folds of inflation in single-field, slow-roll models is suppressed by of order exp(-3N) and we discuss the implications of this result.

  3. Radiation ray measuring device

    International Nuclear Information System (INIS)

    Maekawa, Tatsuyuki; Ida, Masaki.

    1997-01-01

    The present invention provides a chained-radiation ray monitoring system which can be applied to an actual monitoring system of a nuclear power plant or the like. Namely, this device comprises a plurality of scintillation detectors. Each of the detectors has two light take-out ports for emitting light corresponding to radiation rays irradiated from the object of the measurement to optical fibers. In addition, incident light from the optical fiber by way of one of the light take-out optical ports is transmitted to the other of the ports and sent from the other optical port to the fibers. Plurality sets of measuring systems are provided in which each of the detectors are disposed corresponding to a plurality of objects to be measured. A signal processing device is (1) connected with optical fibers of plurality sets of measuring systems in conjunction, (2) detects the optical pulses inputted from the optical fibers to identify the detector from which the optical pulses are sent and (3) measures the amount of radiation rays detected by the identified detector. As a result, the device of the present invention can form a measuring system with redundancy. (I.S.)

  4. Lead Thickness Measurements

    International Nuclear Information System (INIS)

    Rucinski, R.

    1998-01-01

    The preshower lead thickness applied to the outside of D-Zero's superconducting solenoid vacuum shell was measured at the time of application. This engineering documents those thickness measurements. The lead was ordered in sheets 0.09375-inch and 0.0625-inch thick. The tolerance on thickness was specified to be +/- 0.003-inch. The sheets all were within that thickness tolerance. The nomenclature for each sheet was designated 1T, 1B, 2T, 2B where the numeral designates it's location in the wrap and 'T' or 'B' is short for 'top' or 'bottom' half of the solenoid. Micrometer measurements were taken at six locations around the perimeter of each sheet. The width,length, and weight of each piece was then measured. Using an assumed pure lead density of 0.40974 lb/in 3 , an average sheet thickness was calculated and compared to the perimeter thickness measurements. In every case, the calculated average thickness was a few mils thinner than the perimeter measurements. The ratio was constant, 0.98. This discrepancy is likely due to the assumed pure lead density. It is not felt that the perimeter is thicker than the center regions. The data suggests that the physical thickness of the sheets is uniform to +/- 0.0015-inch.

  5. Measurement of short bunches

    International Nuclear Information System (INIS)

    Wang, D.X.

    1996-01-01

    In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson Lab are presented. At Jefferson Lab, bunch lengths as short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented. (author)

  6. Measurement of short bunches

    International Nuclear Information System (INIS)

    Wang, D.X.

    1996-01-01

    In recent years, there has been increasing interest in short electron bunches for different applications such as short wavelength FELs, linear colliders, and advanced accelerators such as laser or plasma wakefield accelerators. One would like to meet various requirements such as high peak current, low momentum spread, high luminosity, small ratio of bunch length to plasma wavelength, and accurate timing. Meanwhile, recent development and advances in RF photoinjectors and various bunching schemes make it possible to generate very short electron bunches. Measuring the longitudinal profile and monitoring bunch length are critical to understand the bunching process and longitudinal beam dynamics, and to commission and operate such short bunch machines. In this paper, several commonly used measurement techniques for subpicosecond bunches and their relative advantages and disadvantages are discussed. As examples, bunch length related measurements at Jefferson lab are presented. At Jefferson Lab, bunch lengths s short as 84 fs have been systematically measured using a zero-phasing technique. A highly sensitive Coherent Synchrotron Radiation (CSR) detector has been developed to noninvasively monitor bunch length for low charge bunches. Phase transfer function measurements provide a means of correcting RF phase drifts and reproducing RF phases to within a couple of tenths of a degree. The measurement results are in excellent agreement with simulations. A comprehensive bunch length control scheme is presented

  7. Semiautomatic assessment of respiratory motion in dynamic MRI. Comparison with simultaneously acquired spirometry

    Energy Technology Data Exchange (ETDEWEB)

    Tetzlaff, R.; Eichinger, M.; Puderbach, M. [Radiologie, Deutsches Krebsforschungszentrum, Heidelberg (Germany); Schoebinger, M.; Meinzer, H.P. [Medizinische und Biologische Informatik, Deutsches Krebsforschungszentrum, Heidelberg (Germany); Kauczor, H.U. [Diagnostische Radiologie, Radiologische Universitaetsklinik, Heidelberg (Germany)

    2008-11-15

    Purpose: supplementing global spirometry with regional information could allow for earlier and more specific diagnosis of lung disease. Dynamic magnetic resonance imaging (dMRI) makes it possible to derive functional parameters from the visualization of the pulmonary motion of single lungs. The aim of this study was to compare high temporal resolution measurements of left and right thoracic diameters to simultaneously acquired spirometry. Materials and methods: 10 healthy volunteers underwent 2-dimensional dMRI of both lungs at 1.5 T. Spirometry was performed simultaneously with an MRI-compatible spirometer. Thoracic diameters were measured semiautomatically and compared to simultaneously measured spirometric volumes. A dMRI surrogate for the Tiffeneau Index was compared to the spirometric Tiffeneau. Results: The volume-time and flow-volume curves from dMRI were very similar to the spirometric curves. The semiautomatically measured diameters correlated well with the spirometric volumes (r > = 0.8, p < 10-15). Agreement between the methods at full temporal resolution was not as convincing (width of 95% limits of agreement interval up to 56%). Good agreement was found between the Tiffenau surrogate and spirometry (width of 95% limits of agreement interval of 14.5%). (orig.)

  8. Semiautomatic assessment of respiratory motion in dynamic MRI. Comparison with simultaneously acquired spirometry

    International Nuclear Information System (INIS)

    Tetzlaff, R.; Eichinger, M.; Puderbach, M.; Schoebinger, M.; Meinzer, H.P.; Kauczor, H.U.

    2008-01-01

    Purpose: supplementing global spirometry with regional information could allow for earlier and more specific diagnosis of lung disease. Dynamic magnetic resonance imaging (dMRI) makes it possible to derive functional parameters from the visualization of the pulmonary motion of single lungs. The aim of this study was to compare high temporal resolution measurements of left and right thoracic diameters to simultaneously acquired spirometry. Materials and methods: 10 healthy volunteers underwent 2-dimensional dMRI of both lungs at 1.5 T. Spirometry was performed simultaneously with an MRI-compatible spirometer. Thoracic diameters were measured semiautomatically and compared to simultaneously measured spirometric volumes. A dMRI surrogate for the Tiffeneau Index was compared to the spirometric Tiffeneau. Results: The volume-time and flow-volume curves from dMRI were very similar to the spirometric curves. The semiautomatically measured diameters correlated well with the spirometric volumes (r > = 0.8, p < 10-15). Agreement between the methods at full temporal resolution was not as convincing (width of 95% limits of agreement interval up to 56%). Good agreement was found between the Tiffenau surrogate and spirometry (width of 95% limits of agreement interval of 14.5%). (orig.)

  9. Thermal Testing Measurements Report

    Energy Technology Data Exchange (ETDEWEB)

    R. Wagner

    2002-09-26

    The purpose of the Thermal Testing Measurements Report (Scientific Analysis Report) is to document, in one report, the comprehensive set of measurements taken within the Yucca Mountain Project Thermal Testing Program since its inception in 1996. Currently, the testing performed and measurements collected are either scattered in many level 3 and level 4 milestone reports or, in the case of the ongoing Drift Scale Test, mostly documented in eight informal progress reports. Documentation in existing reports is uneven in level of detail and quality. Furthermore, while all the data collected within the Yucca Mountain Site Characterization Project (YMP) Thermal Testing Program have been submitted periodically to the Technical Data Management System (TDMS), the data structure--several incremental submittals, and documentation formats--are such that the data are often not user-friendly except to those who acquired and processed the data. The documentation in this report is intended to make data collected within the YMP Thermal Testing Program readily usable to end users, such as those representing the Performance Assessment Project, Repository Design Project, and Engineered Systems Sub-Project. Since either detailed level 3 and level 4 reports exist or the measurements are straightforward, only brief discussions are provided for each data set. These brief discussions for different data sets are intended to impart a clear sense of applicability of data, so that they will be used properly within the context of measurement uncertainty. This approach also keeps this report to a manageable size, an important consideration because the report encompasses nearly all measurements for three long-term thermal tests. As appropriate, thermal testing data currently residing in the TDMS have been reorganized and reformatted from cumbersome, user-unfriendly Input-Data Tracking Numbers (DTNs) into a new set of Output-DTNs. These Output-DTNs provide a readily usable data structure

  10. Optical fuel spray measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hillamo, H.

    2011-07-01

    Diesel fuel sprays, including fuel/air mixing and the physics of two-phase jet formation, are discussed in the thesis. The fuel/air mixing strongly affects emissions formation in spray combustion processes where the local combustion conditions dictate the emission formation. This study comprises optical measurements both in pressurized spray test rigs and in a running engine.The studied fuel injection was arranged with a common rail injection system and the injectors were operated with a solenoid-based injection valve. Both marine and heavy-duty diesel engine injectors were used in the study. Optical fuel spray measurements were carried out with a laser-based double-framing camera system. This kind of equipments is usually used for flow field measurements with Particle Image Velocimetry technique (PIV) as well as for backlight imaging. Fundamental fuel spray properties and spray formation were studied in spray test rigs. These measurements involved studies of mixing, atomization, and the flow field. Test rig measurements were used to study the effect of individual injection parameters and component designs. Measurements of the fuel spray flow field, spray penetration, spray tip velocity, spray angle, spray structure, droplet accumulation, and droplet size estimates are shown. Measurement campaign in a running optically accessible large-bore medium-speed engine was also carried out. The results from engine tests were compared with equivalent test rig measurements, as well as computational results, to evaluate the level of understanding of sprays. It was shown that transient spray has an acceleration and a deceleration phase. Successive flow field measurements (PIV) in optically dense diesel spray resulted in local and average velocity data of diesel sprays. Processing fuel spray generates a flow field to surrounding gas and entrainment of surrounding gas into fuel jet was also seen at the sides of the spray. Laser sheet imaging revealed the inner structure of diesel

  11. Grid-Enabled Measures

    Science.gov (United States)

    Moser, Richard P.; Hesse, Bradford W.; Shaikh, Abdul R.; Courtney, Paul; Morgan, Glen; Augustson, Erik; Kobrin, Sarah; Levin, Kerry; Helba, Cynthia; Garner, David; Dunn, Marsha; Coa, Kisha

    2011-01-01

    Scientists are taking advantage of the Internet and collaborative web technology to accelerate discovery in a massively connected, participative environment —a phenomenon referred to by some as Science 2.0. As a new way of doing science, this phenomenon has the potential to push science forward in a more efficient manner than was previously possible. The Grid-Enabled Measures (GEM) database has been conceptualized as an instantiation of Science 2.0 principles by the National Cancer Institute with two overarching goals: (1) Promote the use of standardized measures, which are tied to theoretically based constructs; and (2) Facilitate the ability to share harmonized data resulting from the use of standardized measures. This is done by creating an online venue connected to the Cancer Biomedical Informatics Grid (caBIG®) where a virtual community of researchers can collaborate together and come to consensus on measures by rating, commenting and viewing meta-data about the measures and associated constructs. This paper will describe the web 2.0 principles on which the GEM database is based, describe its functionality, and discuss some of the important issues involved with creating the GEM database, such as the role of mutually agreed-on ontologies (i.e., knowledge categories and the relationships among these categories— for data sharing). PMID:21521586

  12. Measurements of fireball onset

    Science.gov (United States)

    Scheiner, Brett; Barnat, Edward V.; Baalrud, Scott D.; Hopkins, Matthew M.; Yee, Benjamin T.

    2018-04-01

    Laser-based measurements of the characteristic features of fireball onset and stabilization in response to a stepped voltage applied to an anode immersed in a low pressure (100 mTorr) helium afterglow are reported. These include spatial and temporal evolution of metastable species, electron density, and electric field magnitude as measured by planar laser induced fluorescence, laser-collision induced fluorescence, and laser-induced fluorescence-dip spectroscopy, respectively. These measurements are found to be in qualitative agreement with recent particle-in-cell simulations and theoretical models [Scheiner et al., Phys. Plasmas 24, 113520 (2017)]. The measurements validate the simulations and models in which fireball onset was predicted to follow from the trapping of electrons born from electron impact ionization within a potential well created by a buildup of ions in the sheath. The experimental measurements also demonstrate transient features following the onset that were not present in previous simulations. New simulation results are presented which demonstrate that these features are associated with the abruptness of the voltage step used to initiate fireball onset. An abrupt step in the anode bias causes rapid displacement of ions and an associated plasma potential response following the sheath and fireball expansion.

  13. Neutron fluence measurements

    International Nuclear Information System (INIS)

    1970-01-01

    For research reactor work dealing with such subjects as radiation effects on solids and such disciplines as radiochemistry and radiobiology, the radiation dose or neutron fluence is an essential parameter in evaluating results. Unfortunately it is very difficult to determine. Even when the measurements have been accurate, it is difficult to compare results obtained in different experiments because present methods do not always reflect the dependence of spectra or of different types of radiation on the induced processes. After considering the recommendations of three IAEA Panels, on 'In-pile dosimetry' held in July 1964, on 'Neutron fluence measurements' in October 1965, and on 'In-pile dosimetry' in November 1966, the Agency established a Working Group on Reactor Radiation Measurements. This group consisted of eleven experts from ten different Member States and two staff members of the Agency. In the measurement of energy absorbed by materials from neutrons and gamma rays, there are various reports and reviews scattered throughout the literature. The group, however, considered that the time was ripe for all relevant information to be evaluated and gathered together in the form of a practical guide, with the aim of promoting consistency in the measurement and reporting of reactor radiation. The group arranged for the material to be divided into two manuals, which are expected to be useful both for experienced workers and for beginners

  14. Inmate punishments: Disciplinary measures

    Directory of Open Access Journals (Sweden)

    Milić Ivan D.

    2016-01-01

    Full Text Available After the verdict has become formal and enforceable, and the defendant a convict, sentence execution procedure follows. If the defendant is sentenced to prison, the next step to be taken is the referral institution for execution of sentence of imprisonment. Rules of conduct in the institutions for execution of imprisonment are strictly regulated by legislation governing the rights and obligations of prisoners. Conducts that are prohibited in institutions shall be prescribed as a disciplinary offense, and appropriate disciplinary measures are to be imposed. The subject of this paper are disciplinary measures stipulated by the Law on Execution of Criminal Sanctions of the Republic of Serbia. The paper gives an overview of five disciplinary measures that can be imposed for serious or minor disciplinary offenses. In particular, author focuses his attention to indicating that the imposition and execution of disciplinary measures, are not regulated by Law in the best possible way, so that, in practice, certain problems arise in the application of these measures.

  15. Measuring past a micron...

    CERN Multimedia

    Anaïs Schaeffer

    2011-01-01

    Infinity: That is the name of the new ultra-precision machine used by CERN's Metrology Service to measure the copper components for the CLIC accelerating structures. This project is the result of a collaboration between CLIC and the EN Department. Curious to find out more? Read on because there’ll be an opportunity for you to get a very close look at Infinity!    Infinity, the new, ultra-precise, measuring machine, is currently in operation at the CERN Metrology Service. The CLIC (Compact LInear Collider) radiofrequency structures will operate under very high electric fields (100 MV/m). They should be manufactured within minimal mechanical tolerances. To validate the quality of these components, they have to be measured with a precision that far exceeds the machining tolerances, i.e. 0.3 microns. No “ordinary” measuring machine can achieve this precision, but Infinity, the newly developed high-precision three-dimensional measuring machine i...

  16. The performance measurement manifesto.

    Science.gov (United States)

    Eccles, R G

    1991-01-01

    The leading indicators of business performance cannot be found in financial data alone. Quality, customer satisfaction, innovation, market share--metrics like these often reflect a company's economic condition and growth prospects better than its reported earnings do. Depending on an accounting department to reveal a company's future will leave it hopelessly mired in the past. More and more managers are changing their company's performance measurement systems to track nonfinancial measures and reinforce new competitive strategies. Five activities are essential: developing an information architecture; putting the technology in place to support this architecture; aligning bonuses and other incentives with the new system; drawing on outside resources; and designing an internal process to ensure the other four activities occur. New technologies and more sophisticated databases have made the change to nonfinancial performance measurement systems possible and economically feasible. Industry and trade associations, consulting firms, and public accounting firms that already have well-developed methods for assessing market share and other performance metrics can add to the revolution's momentum--as well as profit from the business opportunities it presents. Every company will have its own key measures and distinctive process for implementing the change. But making it happen will always require careful preparation, perseverance, and the conviction of the CEO that it must be carried through. When one leading company can demonstrate the long-term advantage of its superior performance on quality or innovation or any other nonfinancial measure, it will change the rules for all its rivals forever.

  17. Thermal Properties Measurement Report

    Energy Technology Data Exchange (ETDEWEB)

    Carmack, Jon [Idaho National Lab. (INL), Idaho Falls, ID (United States); Braase, Lori [Idaho National Lab. (INL), Idaho Falls, ID (United States); Papesch, Cynthia [Idaho National Lab. (INL), Idaho Falls, ID (United States); Hurley, David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Tonks, Michael [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Yongfeng [Idaho National Lab. (INL), Idaho Falls, ID (United States); Gofryk, Krzysztof [Idaho National Lab. (INL), Idaho Falls, ID (United States); Harp, Jason [Idaho National Lab. (INL), Idaho Falls, ID (United States); Fielding, Randy [Idaho National Lab. (INL), Idaho Falls, ID (United States); Knight, Collin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Meyer, Mitch [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-08-01

    The Thermal Properties Measurement Report summarizes the research, development, installation, and initial use of significant experimental thermal property characterization capabilities at the INL in FY 2015. These new capabilities were used to characterize a U3Si2 (candidate Accident Tolerant) fuel sample fabricated at the INL. The ability to perform measurements at various length scales is important and provides additional data that is not currently in the literature. However, the real value of the data will be in accomplishing a phenomenological understanding of the thermal conductivity in fuels and the ties to predictive modeling. Thus, the MARMOT advanced modeling and simulation capability was utilized to illustrate how the microstructural data can be modeled and compared with bulk characterization data. A scientific method was established for thermal property measurement capability on irradiated nuclear fuel samples, which will be installed in the Irradiated Material Characterization Laboratory (IMCL).

  18. Challenge Measurements For Authentication

    International Nuclear Information System (INIS)

    Pitts, W. Karl

    2009-01-01

    Authentication of systems with an information barrier that protects sensitive information is difficult; in particular, the information barrier can allow a hidden switch to be implemented by the system fabricator and operator. The hidden switch is the operator's ability to subvert the measurement system and force it to produce a desired and false result. It is usually discussed in the context of an attribute measurement in which a faked item is presented in place of a real item regulated by an agreement, with the driving motivation being the ability to preserve a stock of valuable items. In simple terms, the hidden switch enables a shell game with assets, and the information barrier protects the switch. This presentation outlines challenge measurements that could be used to detect the implementation of a hidden switch and assist the authentication process.

  19. Electrochemical thermodynamic measurement system

    Science.gov (United States)

    Reynier, Yvan [Meylan, FR; Yazami, Rachid [Los Angeles, CA; Fultz, Brent T [Pasadena, CA

    2009-09-29

    The present invention provides systems and methods for accurately characterizing thermodynamic and materials properties of electrodes and electrochemical energy storage and conversion systems. Systems and methods of the present invention are configured for simultaneously collecting a suite of measurements characterizing a plurality of interconnected electrochemical and thermodynamic parameters relating to the electrode reaction state of advancement, voltage and temperature. Enhanced sensitivity provided by the present methods and systems combined with measurement conditions that reflect thermodynamically stabilized electrode conditions allow very accurate measurement of thermodynamic parameters, including state functions such as the Gibbs free energy, enthalpy and entropy of electrode/electrochemical cell reactions, that enable prediction of important performance attributes of electrode materials and electrochemical systems, such as the energy, power density, current rate and the cycle life of an electrochemical cell.

  20. Temperature measurement device

    International Nuclear Information System (INIS)

    Fournier, Christian; Lions, Noel.

    1975-01-01

    The present invention relates to a temperature measuring system that can be applied in particular to monitoring the temperature of the cooling liquid metal of the outlet of the core assemblies of a fast reactor. Said device combines a long hollow metallic pole, at least partially dipped into the liquid metal and constituting a first thermocouple junction between said pole, and two metallic conductors of different nature, joined at one of their ends to constitute the second thermocouple junction. Said conductors suitably insulated are arranged inside a sheath. Said sheath made of the same metals as the pole extends inside the latter and is connected with the pole through a soldered joint. Said reliable system permits an instantaneous measurement of a quantity representing the variations in the recorded temperature and a measurement of the mean surrounding temperature that can be direcly used as a reference for calibrating the first one [fr

  1. Measuring Social Capital

    DEFF Research Database (Denmark)

    Svendsen, Gert Tinggaard; Bjørnskov, Christian

    2007-01-01

    How to construct a robust measure of social capital? This paper contains two contributions. The first is an attempt to establish a broad social capital measure based on four indicators, the Freedom House Index, an index of perceived corruption from Transparency International, and scores on civic...... participation and generalized trust. This measure is then applied by comparing the level of social capital in 25 countries from Western and Eastern Europe. Our nine cluster analysis shows that Switzerland has the highest score, followed by the Netherlands and Scandinavia. At the other end of the continuum we...... find post-communist countries and Southern Italy. The findings for this specific sample suggest that institutions matter for social capital and the relationship between decentralization and social capital emerges as a promising line of inquiry. Thus, the highest scoring countries in the sample may...

  2. Neutron beam measurement dosimetry

    International Nuclear Information System (INIS)

    Amaro, C.R.

    1995-01-01

    This report describes animal dosimetry studies and phantom measurements. During 1994, 12 dogs were irradiated at BMRR as part of a 4 fraction dose tolerance study. The animals were first infused with BSH and irradiated daily for 4 consecutive days. BNL irradiated 2 beagles as part of their dose tolerance study using BPA fructose. In addition, a dog at WSU was irradiated at BMRR after an infusion of BPA fructose. During 1994, the INEL BNCT dosimetry team measured neutron flux and gamma dose profiles in two phantoms exposed to the epithermal neutron beam at the BMRR. These measurements were performed as a preparatory step to the commencement of human clinical trials in progress at the BMRR

  3. Enterprise performance measurement systems

    Directory of Open Access Journals (Sweden)

    Milija Bogavac

    2014-10-01

    Full Text Available Performance measurement systems are an extremely important part of the control and management actions, because in this way a company can determine its business potential, its market power, potential and current level of business efficiency. The significance of measurement consists in influencing the relationship between the results of reproduction (total volume of production, value of production, total revenue and profit and investments to achieve these results (factors of production spending and hiring capital in order to achieve the highest possible quality of the economy. (The relationship between the results of reproduction and investment to achieve them quantitatively determines economic success as the quality of the economy. Measuring performance allows the identification of the economic resources the company has, so looking at the key factors that affect its performance can help to determine the appropriate course of action.

  4. Enhanced Microfluidic Electromagnetic Measurements

    Science.gov (United States)

    Giovangrandi, Laurent (Inventor); Ricco, Antonio J. (Inventor); Kovacs, Gregory (Inventor)

    2015-01-01

    Techniques for enhanced microfluidic impedance spectroscopy include causing a core fluid to flow into a channel between two sheath flows of one or more sheath fluids different from the core fluid. Flow in the channel is laminar. A dielectric constant of a fluid constituting either sheath flow is much less than a dielectric constant of the core fluid. Electrical impedance is measured in the channel between at least a first pair of electrodes. In some embodiments, enhanced optical measurements include causing a core fluid to flow into a channel between two sheath flows of one or more sheath fluids different from the core fluid. An optical index of refraction of a fluid constituting either sheath flow is much less than an optical index of refraction of the core fluid. An optical property is measured in the channel.

  5. Structural power flow measurement

    Energy Technology Data Exchange (ETDEWEB)

    Falter, K.J.; Keltie, R.F.

    1988-12-01

    Previous investigations of structural power flow through beam-like structures resulted in some unexplained anomalies in the calculated data. In order to develop structural power flow measurement as a viable technique for machine tool design, the causes of these anomalies needed to be found. Once found, techniques for eliminating the errors could be developed. Error sources were found in the experimental apparatus itself as well as in the instrumentation. Although flexural waves are the carriers of power in the experimental apparatus, at some frequencies longitudinal waves were excited which were picked up by the accelerometers and altered power measurements. Errors were found in the phase and gain response of the sensors and amplifiers used for measurement. A transfer function correction technique was employed to compensate for these instrumentation errors.

  6. Production measurements at LHCb

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00392425

    2017-01-01

    The $\\text{LHC}b$ detector, with its excellent momentum resolution and flexible trigger strategy, is ideally suited for measuring heavy quark and quarkonia production properties. In addition, the new system of forward shower counters installed upstream and downstream has begun to be used, therefore the experiment is being suited to measure central exclusive production. The $\\text{LHC}b$ measurements of inclusive and differential cross-sections of the production of $J/\\psi$ resonance and $J/\\psi$ pairs, as well bottom quarks and $Z^0$ boson, based on Run 2 datasets are summarized. Finally, results on the prompt production of open charm hadrons and the exclusive production of charmonium are discussed.

  7. Traceability and Measurement Uncertainty

    DEFF Research Database (Denmark)

    Tosello, Guido; De Chiffre, Leonardo

    2004-01-01

    . The project partnership aims (composed by 7 partners in 5 countries, thus covering a real European spread in high tech production technology) to develop and implement an advanced e-learning system that integrates contributions from quite different disciplines into a user-centred approach that strictly....... Machine tool testing 9. The role of manufacturing metrology for QM 10. Inspection planning 11. Quality management of measurements incl. Documentation 12. Advanced manufacturing measurement technology The present report (which represents the section 2 - Traceability and Measurement Uncertainty – of the e-learning......This report is made as a part of the project ‘Metro-E-Learn: European e-Learning in Manufacturing Metrology’, an EU project under the program SOCRATES MINERVA (ODL and ICT in Education), Contract No: 101434-CP-1-2002-1-DE-MINERVA, coordinated by Friedrich-Alexander-University Erlangen...

  8. Post Fukushima measures

    International Nuclear Information System (INIS)

    Mehra, V.K.

    2014-01-01

    'Stress test' of all nuclear power plants initiated in European Union examines robustness of the plant against extreme natural events coupled with loss of all electric power supplies and ultimate heat sink and ineffective counter measures. 'Complementary Safety Measures' suggested by the French Regulatory Authority have enhanced scope of the assessment of resistance to extreme natural events to all nuclear facilities. A truncated system of equipment and systems hardened against extreme events would evolve from such an exercise so that possibility of radioactive release and evacuation of people does not rise again. Computer simulation of the accident at Fukushima Dai-ichi plant was initiated almost simultaneously with the accident. Apart from bench marking the analysis programs, such an exercise will help in quantitative implementation of counter measures and identification of research areas. Additional regulatory requirements are being proposed to prevent core damage or containment failure and to suppress dispersal of radioactive materials

  9. Measuring efficiency in logistics

    Directory of Open Access Journals (Sweden)

    Milan Milovan Andrejić

    2013-06-01

    Full Text Available Dynamic market and environmental changes greatly affect operating of logistics systems. Logistics systems have to realize their activities and processes in an efficient way. The main objective of this paper is to analyze different aspects of efficiency measurement in logistics and to propose appropriate models of measurement. Measuring efficiency in logistics is a complex process that requires consideration of all subsystems, processes and activities as well as the impact of various financial, operational, environmental, quality and other factors. The proposed models have a basis in the Data Envelopment Analysis method. They could help managers in decision making and corrective actions processes. The tests and results of the model show the importance of input and output variables selection.

  10. Measurement of complex surfaces

    International Nuclear Information System (INIS)

    Brown, G.M.

    1993-05-01

    Several of the components used in coil fabrication involve complex surfaces and dimensions that are not well suited to measurements using conventional dimensional measuring equipment. Some relatively simple techniques that are in use in the SSCL Magnet Systems Division (MSD) for incoming inspection will be described, with discussion of their suitability for specific applications. Components that are submitted for MSD Quality Assurance (QA) dimensional inspection may be divided into two distinct categories; the first category involves components for which there is an approved drawing and for which all nominal dimensions are known; the second category involves parts for which 'reverse engineering' is required, the part is available but there are no available drawings or dimensions. This second category typically occurs during development of coil end parts and coil turn filler parts where it is necessary to manually shape the part and then measure it to develop the information required to prepare a drawing for the part

  11. Measuring ambivalence to science

    Science.gov (United States)

    Gardner, P. L.

    Ambivalence is a psychological state in which a person holds mixed feelings (positive and negative) towards some psychological object. Standard methods of attitude measurement, such as Likert and semantic differential scales, ignore the possibility of ambivalence; ambivalent responses cannot be distinguished from neutral ones. This neglect arises out of an assumption that positive and negative affects towards a particular psychological object are bipolar, i.e., unidimensional in opposite directions. This assumption is frequently untenable. Conventional item statistics and measures of test internal consistency are ineffective as checks on this assumption; it is possible for a scale to be multidimensional and still display apparent internal consistency. Factor analysis is a more effective procedure. Methods of measuring ambivalence are suggested, and implications for research are discussed.

  12. The measurement of sparkle

    Science.gov (United States)

    Ferrero, A.; Bayón, S.

    2015-04-01

    Sparkle is a non-uniform texture effect consisting of very bright spots distributed on a dark surround. To date the only commercially-available instrument able to quantify sparkle is BYK-mac. This instrument allows sparkle parameters to be obtained, which should correlate with the visual experience. However, the measurands corresponding to these parameters are not clearly defined and they cannot be measured by any other instruments. In this article, we describe a procedure to measure quantities of well-defined sparkle measurands. We present experimental results at a combination of well-distributed illumination/viewing geometries within the incident plane. From this study, four descriptors are derived which may be correlated with visual attributes of sparkle. Finally, the procedure to estimate the perceived sparkle at any given surround luminance from the measured sparkle quantities is explained.

  13. B meson lifetime measurement

    International Nuclear Information System (INIS)

    Piccolo, M.

    1989-01-01

    The lifetime of hadrons containing b-quark has been the subject of extensive experimental work and theoretical speculation; its importance is due to implications on some of the fundamental parameters of the Standard Model, such as the top quark mass and the mixing angles. Since the pioneer measurements of the MAC and MARK II collaborations at PEP in 1983 the progress has been impressive; but many issues still remain open and await further study. In this paper the field's present status is discussed. An overview of the theoretical motivations for this measurements in the Standard Model framework is done. Then the experimental techniques used are reviewed, emphasizing the most recent measurements. A comparison of the results obtained is done and systematic errors are discussed. In conclusion there are some remarks on the further developments foreseen in the near future

  14. Measuring marketing effectiveness.

    Science.gov (United States)

    Gluckman, J; Michaelis, T

    1987-09-01

    The most frequent question about the marketing function in hospitals today is, What are we getting for our money? To answer this, marketing directors must convince the board first of the need for marketing, then of marketing's effectiveness. To measure marketing effectiveness, some basic needs are a staff, equipment, cooperation between departments, utilization data, and a research budget. Some steps to be followed include developing a marketing data base--consisting of demographic projections, demand projections, and market share--testing a marketing strategy through experimentation, documenting the expected results and measurement techniques, and calculating the expected return on investments. In dealing with those "impossible-to-measure" cases, such as a physician who is not advertising but finds that a competitor is, a decision tree can help determine whether to advertise and how much to spend by indicating what the return on investment might be.

  15. Workload measurement: diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nuss, Wayne [The Prince Charles Hospital, Chermside, QLD (Australia). Dept. of Medical Imaging

    1993-06-01

    Departments of medical imaging, as with many other service departments in the health industry, are being asked to develop performance indicators. No longer are they assured that annual budget allocations will be forthcoming without justification or some output measurement indicators that will substantiate a claim for a reasonable share of resources. The human resource is the most valuable and the most expensive to any department. This paper provides a brief overview of the research and implementation of a radiographer workload measurement system that was commenced in the Brisbane North Health Region. 2 refs., 10 tabs.

  16. Probability and Measure

    CERN Document Server

    Billingsley, Patrick

    2012-01-01

    Praise for the Third Edition "It is, as far as I'm concerned, among the best books in math ever written....if you are a mathematician and want to have the top reference in probability, this is it." (Amazon.com, January 2006) A complete and comprehensive classic in probability and measure theory Probability and Measure, Anniversary Edition by Patrick Billingsley celebrates the achievements and advancements that have made this book a classic in its field for the past 35 years. Now re-issued in a new style and format, but with the reliable content that the third edition was revered for, this

  17. Preventive measures for emergencies?

    International Nuclear Information System (INIS)

    Calliess, J.

    1990-01-01

    The meeting discussed the new provisions for civil defense on account of the amended Disaster Control Act which had been recently adopted by the Lower House of Parliament. In 6 working groups it was discussed how appropriate and sensible the attempt is to make provisions for civil defence in order to protect the population, and how adequate legislative measures are in the face of true threat and var scenarios. Ethical aspects and aspects of international law were considered, as well as the role of public health and free charitable institutions concering preventive measures in emergencies. (orig. HSCH) [de

  18. Measuring depth in boreholes

    International Nuclear Information System (INIS)

    Hodson, G.M.

    1979-01-01

    This invention relates to a method of determining the depth of rock strata and other features of a borehole. It may be employed with particular advantage when access to the top of the borehole is difficult, for example in underwater operations. A radioactive marker, such as a source of gamma rays, is positioned near the top of the riser of a sub-sea wellhead structure. A radiation detector is lowered between the marker and a radioactive stratum and the length of line supplied is measured on the floating platform. This enables the depth of the stratum to be measured irrespective of tidal variations of the height of the platform. (U.K.)

  19. Rectenna array measurement results

    Science.gov (United States)

    Dickinson, R. M.

    1980-01-01

    The measured performance characteristics of a rectenna array are reviewed and compared to the performance of a single element. It is shown that the performance may be extrapolated from the individual element to that of the collection of elements. Techniques for current and voltage combining were demonstrated. The array performance as a function of various operating parameters is characterized and techniques for overvoltage protection and automatic fault clearing in the array demonstrated. A method for detecting failed elements also exists. Instrumentation for deriving performance effectiveness is described. Measured harmonic radiation patterns and fundamental frequency scattered patterns for a low level illumination rectenna array are presented.

  20. Productivity and Performance Measurement

    DEFF Research Database (Denmark)

    Hald, Kim Sundtoft; Spring, Martin

    This study explores conceptually how performance measurement as discussed in the literature, enables or constrains the ability to manage and improve productivity. It uses an inter-disciplinary literature review to identify five areas of concern relating productivity accounting to the ability...... to improve productivity: “Productivity representation”; “productivity incentives”, “productivity intervention”; “productivity trade-off or synergy” and “productivity strategy and context”. The paper discusses these areas of concern and expands our knowledge of how productivity and performance measurement...

  1. Temperature measurement device

    International Nuclear Information System (INIS)

    Oltman, B.G.; Eckerman, K.F.; Romberg, G.P.; Prepejchal, W.

    1975-01-01

    Thermoluminescent dosimeter (TLD) material is exposed to a known amount of radiation and then exposed to the environment where temperature measurements are to be taken. After a predetermined time period, the TLD material is read in a known manner to determine the amount of radiation energy remaining in the TLD material. The difference between the energy originally stored by irradiation and that remaining after exposure to the temperature ofthe environment is a measure of the average temperature of the environment during the exposure. (U.S.)

  2. Fission gas measuring technology

    International Nuclear Information System (INIS)

    Lee, Hyung Kwon; Kim, Eun Ka; Hwang, Yong Hwa; Lee, Eun Pyo; Chun, Yong Bum; Seo, Ki Seog; Park, Dea Gyu; Chu, Yong Sun; Ahn, Sang Bok.

    1998-02-01

    Safety and economy of nuclear plant are greatly affected by the integrity of nuclear fuels during irradiation reactor core. A series of post-irradiation examination (PIE) including non-destructive and destructive test is to be conducted to evaluate and characterize the nuclear performance. In this report, a principle of the examination equipment to measure and analyse fission gases existing nuclear fuels were described and features of the component and device consisting the fission gas measuring equipment are investigated. (author). 4 refs., 2 tabs., 6 figs

  3. Fission gas measuring technology

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyung Kwon; Kim, Eun Ka; Hwang, Yong Hwa; Lee, Eun Pyo; Chun, Yong Bum; Seo, Ki Seog; Park, Dea Gyu; Chu, Yong Sun; Ahn, Sang Bok

    1998-02-01

    Safety and economy of nuclear plant are greatly affected by the integrity of nuclear fuels during irradiation reactor core. A series of post-irradiation examination (PIE) including non-destructive and destructive test is to be conducted to evaluate and characterize the nuclear performance. In this report, a principle of the examination equipment to measure and analyse fission gases existing nuclear fuels were described and features of the component and device consisting the fission gas measuring equipment are investigated. (author). 4 refs., 2 tabs., 6 figs.

  4. Residual-stress measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ezeilo, A N; Webster, G A [Imperial College, London (United Kingdom); Webster, P J [Salford Univ. (United Kingdom)

    1997-04-01

    Because neutrons can penetrate distances of up to 50 mm in most engineering materials, this makes them unique for establishing residual-stress distributions non-destructively. D1A is particularly suited for through-surface measurements as it does not suffer from instrumental surface aberrations commonly found on multidetector instruments, while D20 is best for fast internal-strain scanning. Two examples for residual-stress measurements in a shot-peened material, and in a weld are presented to demonstrate the attractive features of both instruments. (author).

  5. Creep Measurement Video Extensometer

    Science.gov (United States)

    Jaster, Mark; Vickerman, Mary; Padula, Santo, II; Juhas, John

    2011-01-01

    Understanding material behavior under load is critical to the efficient and accurate design of advanced aircraft and spacecraft. Technologies such as the one disclosed here allow accurate creep measurements to be taken automatically, reducing error. The goal was to develop a non-contact, automated system capable of capturing images that could subsequently be processed to obtain the strain characteristics of these materials during deformation, while maintaining adequate resolution to capture the true deformation response of the material. The measurement system comprises a high-resolution digital camera, computer, and software that work collectively to interpret the image.

  6. Intercalibration of transuranic measurements

    International Nuclear Information System (INIS)

    Fukai, R.; Ballestra, S.; Thein, M.

    1982-01-01

    One of the major objectives of the coordinated research programme on Transuranic Cycling Behaviour in the Marine Environment has been to achieve the comparability of the measurement results among the laboratories from different countries participating in the programme. In order to fulfil this objective, the intercalibration exercises of transuranic measurements using sea water and sediment samples were organized by the Monaco Laboratory within the duration of the programme in 1979-1981. The sediment and sea water samples were collected respectively by the Bhabha Atomic Research Centre of India and the Hydrographic Institute of the Federal Republic of Germany. In the present report the results of these intercalibration exercises are surveyed

  7. Geometric multipartite entanglement measures

    International Nuclear Information System (INIS)

    Paz-Silva, Gerardo A.; Reina, John H.

    2007-01-01

    Within the framework of constructions for quantifying entanglement, we build a natural scenario for the assembly of multipartite entanglement measures based on Hopf bundle-like mappings obtained through Clifford algebra representations. Then, given the non-factorizability of an arbitrary two-qubit density matrix, we give an alternate quantity that allows the construction of two types of entanglement measures based on their arithmetical and geometrical averages over all pairs of qubits in a register of size N, and thus fully characterize its degree and type of entanglement. We find that such an arithmetical average is both additive and strongly super additive

  8. Measuring your radon risk

    International Nuclear Information System (INIS)

    Mackmurdo, R.

    1994-01-01

    In its annual report for 1992/93, the NRPB has warned that tens of thousands of UK employees may be exposed to high levels of radon at work. In addition to those who work underground, employees at risk of radon-induced lung cancer are typically those who spend long periods indoors. This article reviews the implications for all employers especially those in low or unknown levels of radon who resist taking measurements in the belief that by not measuring, they are not liable. (UK)

  9. Measuring pollution prevention

    International Nuclear Information System (INIS)

    Stephan, D.G.; Bridges, J.S.

    1992-01-01

    To assess progress in pollution prevention, estimates or measurements of the amounts of pollution actually prevented have to be made. Such estimates or measurements tell us how far we have come and, possibly, how much farther there is to go in utilizing pollution prevention as a tool for improving environmental quality. They can, theoretically, be used to assess progress on a scale ranging from the individual facility or even the individual process or activity generation wastes to scale as large as a geographical area such as a county, a state or even the United States as a whole. 3 refs

  10. Measuring green jobs?

    DEFF Research Database (Denmark)

    Zandersen, Marianne; Martinsen, Louise

    2012-01-01

    The report reviews the different initiatives aiming to measure aspects of “green” sectors, jobs and technologies. The report discusses whether the statistics collected under the present initiatives aimed at measuring these aspects increase insights into the fundamental questions motivating...... the initiatives. An alternative framework is suggested, as it appears fundamentally impossible to make consistent frameworks for a division of the economy into “green” and “non-green” activities. The analysis has been carried out during the period September 2011 – March 2012 by Vista Analysis AS, Gaia Consulting...

  11. Simulations with complex measure

    International Nuclear Information System (INIS)

    Markham, J.K.; Kieu, T.D.

    1997-01-01

    A method is proposed to handle the sign problem in the simulation of systems having indefinite or complex-valued measures. In general, this new approach, which is based on renormalisation blocking, is shown to yield statistical errors smaller that the crude Monte Carlo method using absolute values of the original measures. The improved method is applied to the 2D Ising model with temperature generalised to take on complex values. It is also adapted to implement Monte Carlo Renormalisation Group calculations of the magnetic and thermal critical exponents. 10 refs., 4 tabs., 7 figs

  12. Transverse betatron tune measurements

    International Nuclear Information System (INIS)

    Serio, M.

    1989-01-01

    In this paper the concept of the betatron tune and the techniques to measure it are discussed. The smooth approximation is introduced along with the terminology of betatron oscillations, phase advance and tune. Single particle and beam spectra in the presence of synchro-betatron oscillations are treated with emphasis on the consequences of sampling the beam position. After a general presentation of various kinds of beam position monitors and transverse kickers, the time domain and frequency domain analysis of the beam response to a transverse excitation are discussed and several methods and applications of the tune measurements are listed

  13. [Playing of wind instruments is associated with an obstructive pattern in the spirometry of adolescents with a good aerobic resistance capacity].

    Science.gov (United States)

    Granell, Javier; Granell, Jose; Ruiz, Diana; Tapias, Jose A

    2011-03-01

    There is controversy in the medical literature regarding the beneficial or detrimental effects of playing wind musical instruments on the respiratory system. The aim of this study is to analyse this relationship, taking the physical condition of the subjects into consideration. Cross-sectional observational study. Public institution with coordinated medium grade musical instruction and primary and secondary education. Young performers (between 13 and 17 years). We collected basic epidemiological parameters (gender, age, weight, size, heath status), and each subject underwent a fitness test ("course navette" cardiorespiratory fitness test) and a forced spirometry. We included 90 students, 53 females and 37 males. Thirty two were wind instrument players and 58 studied other instruments. The two groups were homogeneous with respect to gender, age and body mass index. The maximum oxygen uptake showed no significant difference (P=0.255), further demonstrating an adequate level of fitness compared to the general population. FVC was normal and similar in both groups (P=0.197). The FEV(1) percentage and the FEV(1)/FVC ratio were significantly lower (Pstudy of wind instruments was associated with an obstructive spirometric pattern in young musicians with a normal level of physical fitness. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  14. Liquid metal level measurement

    International Nuclear Information System (INIS)

    Hale, J.C.; Leyland, K.S.

    1982-01-01

    A liquid metal level indicator is described which can be used to measure, in a stainless steel tank, the level of a nuclear reactor coolant such as sodium. The instrument, which is based on the eddy current induction effect, gives readings over substantially the full depth of the tank and indicates the sense of change of level. (U.K.)

  15. Health Physics Measurements Services

    Energy Technology Data Exchange (ETDEWEB)

    Carchon, R

    2001-04-01

    SCK-CEN's programme on health physics measurements includes various activities in dosimetry, calibration , instrumentation , gamma-ray spectrometry, whole body counting , the preparation of standard sources, non-destructive assay and the maintenance of Euratom Fork detectors. Main achievements in these topical areas in 2000 are summarised.

  16. Dialogue scanning measuring systems

    International Nuclear Information System (INIS)

    Borodyuk, V.P.; Shkundenkov, V.N.

    1985-01-01

    The main developments of scanning measuring systems intended for mass precision processsing of films in nuclear physics problems and in related fields are reviewed. A special attention is paid to the problem of creation of dialogue systems which permit to simlify the development of control computer software

  17. NSR superstring measures revisited

    International Nuclear Information System (INIS)

    Morozov, A.

    2008-01-01

    Review of remarkable progress in evaluation of NSR superstring measures, originated by E.D'Hoker and D.Phong. These recent results are presented in the old-fashioned form, what allows to highlight the options which have been overlooked in original considerations in late 1980's.

  18. Fire protection measures

    International Nuclear Information System (INIS)

    Bittner

    1997-01-01

    The presentation could only show a very brief overview of the analysis results of a wide study of the existing fire protection situation at Mochovce. As far not already done the next steps will be the selection of the final suppliers of the different measures, the detailed design and the implementation of the measures. As part of the further assistance in fire protection EUCOM will perform compliance checks of the DD and implementation and assist EMO for raising problems. Especially during the implementation of the measures the belonging quality checks have a high priority. Assuming that the implementation of measures will be in accordance with with the study results and the relevant basic design requirements it can be stated that safety level concerning fire protection will be in accordance with international requirement like IAEA 50 SG D2. The next step of our work will be the delta analysis for 2 unit and the relevant basic design as far as there are differences to unit 1. (author)

  19. Connectivity measures: a review

    Czech Academy of Sciences Publication Activity Database

    Kindlmann, Pavel; Burel, F.

    2008-01-01

    Roč. 23, č. 1 (2008), s. 879-890 ISSN 0921-2973 R&D Projects: GA MŠk LC06073; GA AV ČR(CZ) IAA6087301 Institutional research plan: CEZ:AV0Z60870520 Keywords : Conservation biology * Habitat fragmentation * Landscape connectivity * Measures * Species extinction Subject RIV: EH - Ecology, Behaviour Impact factor: 2.453, year: 2008

  20. Measures for speed management.

    NARCIS (Netherlands)

    2009-01-01

    Measures for speed management are essential for limiting the negative effects of driving too fast and at inappropriate speeds. To begin with, safe and credible speed limits need to be determined. Dynamic and variable speed limits that take into account the current circumstances, such as weather

  1. Measuring Cultural Diversity

    DEFF Research Database (Denmark)

    Patsiurko, Natalka; Campbell, John L.; Hall, John A.

    2012-01-01

    Many claim that national economic success depends upon cultural homogeneity. We collect new time-series data and develop new measures of ethnic, linguistic and religious fractionalization for the OECD countries. We show that cultural diversity may vary by type across countries and over short peri...

  2. Position measuring device

    International Nuclear Information System (INIS)

    Maeda, Kazuyuki; Takahashi, Shuichi; Maruyama, Mayumi

    1998-01-01

    The present invention provides a device capable of measuring accurate position and distance easily even at places where operator can not easily access, such as cell facilities for vitrifying radioactive wastes. Referring to a case of the vitrifying cell, an objective equipment settled in the cell is photographed by a photographing device. The image is stored in a position measuring device by way of an image input device. After several years, when the objective equipment is exchanged, a new objective equipment is photographed by a photographing device. The image is also stored in the position measuring device. The position measuring device compares the data of both of the images on the basis of pixel unit. Based on the image of the equipment before the exchange as a reference, extent of the displacement of the installation position of the equipment on the image after the exchange caused by installation error and manufacturing error is determined to decide the position of the equipment after exchange relative to the equipment before exchange. (I.S.)

  3. Radiation flux measuring device

    International Nuclear Information System (INIS)

    Corte, E.; Maitra, P.

    1977-01-01

    A radiation flux measuring device is described which employs a differential pair of transistors, the output of which is maintained constant, connected to a radiation detector. Means connected to the differential pair produce a signal representing the log of the a-c component of the radiation detector, thereby providing a signal representing the true root mean square logarithmic output. 3 claims, 2 figures

  4. Measurements for municipalities 2007

    NARCIS (Netherlands)

    B. Kuhry; J.J.J. Jonker; with participation of M. Ras

    2007-01-01

    Original title: Maten voor gemeenten 2007. Measurements for municipalities 2007 presents a national picture of the performance delivered by local authorities and the costs of doing so. The analyses relate to the period 2000-2005. This is the fifth time this quantitative and integrated picture

  5. Measurements for municipalities 2006

    NARCIS (Netherlands)

    B. Kuhry; J.J.J. Jonker; with cooperation of Bureau Zenc

    2006-01-01

    Original title: Maten voor gemeenten 2006. Measurements for municipalities 2006 (Maten voor gemeenten 2006) presents a national picture of the performance delivered by local authorities and the costs of doing so. The analyses relate to the period 1999-2004. This is the fourth time

  6. EBRII cask characterization measurements

    International Nuclear Information System (INIS)

    Haggard, D.L.; Brackenbush, L.W.

    1996-01-01

    This report describes the measurements performed to provide the radionuclide content and verify the stated mass of special nuclear material (SNM) in Experimental Breeder Reactor EBRII casks stored in Trench 1, Burial Ground 4C, 218-WAC 200 West Area. this information is needed to characterize the curie content of each cask and the total curies in the storage area. Gamma assay techniques typically employed for nondestructive assay (NDA) were used to determine the gamma-emitting isotopes in each cask, which were fission and activation products from the spent fuel. Passive neutron counting was selected to verify the stated plutonium content because the fission and activation products masked any gamma emissions from plutonium. The fast neutrons emitted by plutonium are highly penetrating and easily detected through several inches of shielding. A slab neutron detector containing five 3 He proportional counters was used to determine the neutron emission rates and estimate the mass of plutonium present. The measurements followed the methods and procedures routinely used for nuclear waste assay and safeguard measurements. The measured neutron yields confirmed the declared plutonium content for the fuel elements, with the exception of several casks that contained recycled plutonium or americium target material. In these casks, the 244 Cm content masked the neutron emissions from any plutonium. For these casks, the plutonium content was estimated by correlation with the 244 Cm neutron emissions

  7. Electromagnetic distance measurement

    CERN Document Server

    1967-01-01

    This book brings together the work of forty-eight geodesists from twenty-five countries. They discuss various new electromagnetic distance measurement (EDM) instruments - among them the Tellurometer, Geodimeter, and air- and satellite-borne systems - and investigate the complex sources of error.

  8. Measuring Firm Performance

    DEFF Research Database (Denmark)

    Assaf, A. George; Josiassen, Alexander; Gillen, David

    2014-01-01

    Set in the airport industry, this paper measures firm performance using both desirable and bad outputs (i.e. airport delays). We first estimate a model that does not include the bad outputs and then a model that includes bad outputs. The results show important differences in the efficiency...

  9. Measuring the chargino parameters

    Indian Academy of Sciences (India)

    by measuring the cross-sections with polarized beams at e+e- collider ... is given by the fundamental SUSY parameters: the SU(2) gaugino mass Е¾, the higgsino .... two points in the plane which are symmetric under the interchange ¾Д ° ¾К.

  10. Measurement of Humidity

    NARCIS (Netherlands)

    Regtien, Paulus P.L.

    2005-01-01

    The project COMET provides a multimedia training package for metrology and measurement. The package is developed by a consortium of 10 institutes from 7 European countries. It consists of 31 modules, each dealing with a particular aspect of metrology, and is available in English, German, French and

  11. Customer satisfaction measurement

    Directory of Open Access Journals (Sweden)

    Maričić Branko R.

    2012-01-01

    Full Text Available Customer satisfaction is important in business management as a basis for long-term profitability of a single line of products and services and the company as a whole. Customer satisfaction in modern market conditions is characterized by a large number of alternatives that can satisfy the same need or desire of consumers, and are a prerequisite for the retention, loyalty, and positive verbal communication between companies and vendors on one hand and consumers on the other. Companies are investing more and more investment and management efforts in improving customer satisfaction. Improving customer satisfaction and its measurement involves the taking of appropriate marketing strategies and tactics, as well as corrective measures. This paper presents the well-known attempts to measure customers' satisfaction at the macro and micro level of marketing analysis. The index of consumer satisfaction is an important indicator of achieved quality and market performance of companies and can be measured on a micro and macro level. National customer satisfaction indexes are useful framework for analyzing the competitiveness of national economies, industries and individual companies and are used for a variety of other aspects of observation and analysis. Standardization of consumer satisfaction indexes in different countries allows comparability of the data, giving a new quality of analysis in the era of globalization and internationalization of business.

  12. AA magnet measurement team

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    Quickly improvised measurement equipment for the AA (Antiproton Accumulator) was all the tight schedule permitted, but the high motivation of the team made up for the lack of convenience. From left to right: Roy Billinge (Joint AA Project Leader, the other one was Simon van der Meer); Bruno Autin, Brian Pincott, Colin Johnson.

  13. Measuring Neurotic Behavior.

    Science.gov (United States)

    Blai, Boris, Jr.

    An exploratory study concerned with the measurement of perseveration, or persistence, as a personality variable was based on the work of G.V. Hamilton, an early investigator in the field. Persistently maladaptive behavior was hypothesized to be a chief characteristic of neurosis. An experimental problem-solving situation was designed to…

  14. Measured attenuation correction methods

    International Nuclear Information System (INIS)

    Ostertag, H.; Kuebler, W.K.; Doll, J.; Lorenz, W.J.

    1989-01-01

    Accurate attenuation correction is a prerequisite for the determination of exact local radioactivity concentrations in positron emission tomography. Attenuation correction factors range from 4-5 in brain studies to 50-100 in whole body measurements. This report gives an overview of the different methods of determining the attenuation correction factors by transmission measurements using an external positron emitting source. The long-lived generator nuclide 68 Ge/ 68 Ga is commonly used for this purpose. The additional patient dose from the transmission source is usually a small fraction of the dose due to the subsequent emission measurement. Ring-shaped transmission sources as well as rotating point or line sources are employed in modern positron tomographs. By masking a rotating line or point source, random and scattered events in the transmission scans can be effectively suppressed. The problems of measured attenuation correction are discussed: Transmission/emission mismatch, random and scattered event contamination, counting statistics, transmission/emission scatter compensation, transmission scan after administration of activity to the patient. By using a double masking technique simultaneous emission and transmission scans become feasible. (orig.)

  15. Comparing Harmonic Similarity Measures

    NARCIS (Netherlands)

    de Haas, W.B.; Robine, M.; Hanna, P.; Veltkamp, R.C.; Wiering, F.

    2010-01-01

    We present an overview of the most recent developments in polyphonic music retrieval and an experiment in which we compare two harmonic similarity measures. In contrast to earlier work, in this paper we specifically focus on the symbolic chord description as the primary musical representation and

  16. Measurement Science and Training.

    Science.gov (United States)

    Bunderson, C. Victor

    The need for training and retraining is a central element in current discussions about the economy of the United States. This paper is designed to introduce training practitioners to some new concepts about how measurement science can provide a new framework for assessing progress and can add new discipline to the development, implementation, and…

  17. Fuzzy measures and integrals

    Czech Academy of Sciences Publication Activity Database

    Mesiar, Radko

    2005-01-01

    Roč. 28, č. 156 (2005), s. 365-370 ISSN 0165-0114 R&D Projects: GA ČR(CZ) GA402/04/1026 Institutional research plan: CEZ:AV0Z10750506 Keywords : fuzzy measures * fuzzy integral * regular fuzzy integral Subject RIV: BA - General Mathematics Impact factor: 1.039, year: 2005

  18. Precision measurements in supersymmetry

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Johnathan Lee [Stanford Univ., CA (United States)

    1995-05-01

    Supersymmetry is a promising framework in which to explore extensions of the standard model. If candidates for supersymmetric particles are found, precision measurements of their properties will then be of paramount importance. The prospects for such measurements and their implications are the subject of this thesis. If charginos are produced at the LEP II collider, they are likely to be one of the few available supersymmetric signals for many years. The author considers the possibility of determining fundamental supersymmetry parameters in such a scenario. The study is complicated by the dependence of observables on a large number of these parameters. He proposes a straightforward procedure for disentangling these dependences and demonstrate its effectiveness by presenting a number of case studies at representative points in parameter space. In addition to determining the properties of supersymmetric particles, precision measurements may also be used to establish that newly-discovered particles are, in fact, supersymmetric. Supersymmetry predicts quantitative relations among the couplings and masses of superparticles. The author discusses tests of such relations at a future e{sup +}e{sup {minus}} linear collider, using measurements that exploit the availability of polarizable beams. Stringent tests of supersymmetry from chargino production are demonstrated in two representative cases, and fermion and neutralino processes are also discussed.

  19. Measuring Normative Risk Preferences

    NARCIS (Netherlands)

    G.A.G. Alserda (Gosse)

    2017-01-01

    textabstractThe results of eliciting risk preferences depend on the elicitation method. Different methods of measuring the same variable tend to produce different results. This raises the question whether normative risk preferences can be elicited at all. Using two types of manipulation, I assess

  20. Inclusion: Conceptualization and measurement

    NARCIS (Netherlands)

    Jansen, W.S.; Otten, S.; Van der Zee, K.I.; Jans, L.

    2014-01-01

    n the present research, we introduced a conceptual framework of inclusion and subsequently used this as a starting point to develop and validate a scale to measure perceptions of inclusion. Departing from existing work on inclusion and complementing this with theoretical insights from optimal

  1. Inclusion : Conceptualization and measurement

    NARCIS (Netherlands)

    Jansen, Wiebren S.; Otten, Sabine; van der Zee, Karen I.; Jans, Lise

    In the present research, we introduced a conceptual framework of inclusion and subsequently used this as a starting point to develop and validate a scale to measure perceptions of inclusion. Departing from existing work on inclusion and complementing this with theoretical insights from optimal

  2. Inclusion: Conceptualization and measurement

    NARCIS (Netherlands)

    Jansens, Wiebren S.; Otten, Sabine; van der Zee, Karen; Jans, Lise

    2014-01-01

    In the present research, we introduced a conceptual framework of inclusion and subsequently used this as a starting point to develop and validate a scale to measure perceptions of inclusion. Departing from existing work on inclusion and complementing this with theoretical insights from optimal

  3. Temperature measurements by thermocouples

    International Nuclear Information System (INIS)

    Liermann, J.

    1975-01-01

    The measurement of a temperature (whatever the type of transducer used) raises three problems: the choice of transducer; where it should be placed; how it should be fixed and protected. These are the three main points examined, after a brief description of the most commonly used thermocouples [fr

  4. Health Physics Measurements Services

    International Nuclear Information System (INIS)

    Carchon, R.

    2001-01-01

    SCK-CEN's programme on health physics measurements includes various activities in dosimetry, calibration , instrumentation , gamma-ray spectrometry, whole body counting , the preparation of standard sources, non-destructive assay and the maintenance of Euratom Fork detectors. Main achievements in these topical areas in 2000 are summarised

  5. Measure Guideline: Ventilation Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Springer, D. [Alliance for Residential Building Innovation (ARBI), David, CA (United States); Dakin, B. [Alliance for Residential Building Innovation (ARBI), David, CA (United States); German, A. [Alliance for Residential Building Innovation (ARBI), David, CA (United States)

    2012-04-01

    The purpose of this measure guideline is to provide information on a cost-effective solution for reducing cooling system energy and demand in homes located in hot-dry and cold-dry climates. This guideline provides a prescriptive approach that outlines qualification criteria, selection considerations, and design and installation procedures.

  6. Refractive index based measurements

    DEFF Research Database (Denmark)

    2014-01-01

    In a method for performing a refractive index based measurement of a property of a fluid such as chemical composition or temperature, a chirp in the local spatial frequency of interference fringes of an interference pattern is reduced by mathematical manipulation of the recorded light intensity...

  7. Measurement and Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Kirkham, Harold

    2018-01-02

    This is a chapter for a book called the Standard Handbook for Electrical Engineering. Though it is not obvious from the title, the book deals mainly with power engineering. The first chapter (not mine) is about the fundamental quantities used in measurement. This chapter is about the process and the instrumentation.

  8. First Measurement of $\

    Energy Technology Data Exchange (ETDEWEB)

    Palomino Gallo, Jose Luis [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro (Brazil)

    2012-12-01

    Understanding of the $\\pi^0$ production via anti-neutrino-nucleus charged current interaction in the neutrino energy region of 1-10 GeV is essential for neutrino oscillation experiments. In this thesis, we present a measurement of charged current $\\pi^0$ production from anti-muon neutrinos scattering on a polystyrene scintillator (CH) target in the MINER$\

  9. Benchmarking and Performance Measurement.

    Science.gov (United States)

    Town, J. Stephen

    This paper defines benchmarking and its relationship to quality management, describes a project which applied the technique in a library context, and explores the relationship between performance measurement and benchmarking. Numerous benchmarking methods contain similar elements: deciding what to benchmark; identifying partners; gathering…

  10. Measures against nuclear accidents

    International Nuclear Information System (INIS)

    1992-01-01

    A select committee appointed by the Norwegian Ministry of Social Affairs put forward proposals concerning measures for the improvement of radiation protection preparedness in Norway. On the basis on an assessment of the potential radiation accident threat, the report examines the process of response, and identifies the organizational and management factors that influence that process

  11. EDITORIAL: Microwave Moisture Measurements

    Science.gov (United States)

    Kaatze, Udo; Kupfer, Klaus; Hübner, Christof

    2007-04-01

    Microwave moisture measurements refer to a methodology by which the water content of materials is non-invasively determined using electromagnetic fields of radio and microwave frequencies. Being the omnipresent liquid on our planet, water occurs as a component in most materials and often exercises a significant influence on their properties. Precise measurements of the water content are thus extremely useful in pure sciences, particularly in biochemistry and biophysics. They are likewise important in many agricultural, technical and industrial fields. Applications are broad and diverse, and include the quality assessment of foodstuffs, the determination of water content in paper, cardboard and textile production, the monitoring of moisture in sands, gravels, soils and constructions, as well as the measurement of water admixtures to coal and crude oil in reservoirs and in pipelines. Microwave moisture measurements and evaluations require insights in various disciplines, such as materials science, dielectrics, the physical chemistry of water, electrodynamics and microwave techniques. The cooperation of experts from the different fields of science is thus necessary for the efficient development of this complex discipline. In order to advance cooperation the Workshop on Electromagnetic Wave Interaction with Water and Moist Substances was held in 1993 in Atlanta. It initiated a series of international conferences, of which the last one was held in 2005 in Weimar. The meeting brought together 130 scientists and engineers from all over the world. This special issue presents a collection of some selected papers that were given at the event. The papers cover most topics of the conference, featuring dielectric properties of aqueous materials, electromagnetic wave interactions, measurement methods and sensors, and various applications. The special issue is dedicated to Dr Andrzej W Kraszewski, who died in July 2006 after a distinguished career of 48 years in the research of

  12. Strategic Measures of Teacher Performance

    Science.gov (United States)

    Milanowski, Anthony

    2011-01-01

    Managing the human capital in education requires measuring teacher performance. To measure performance, administrators need to combine measures of practice with measures of outcomes, such as value-added measures, and three measurement systems are needed: classroom observations, performance assessments or work samples, and classroom walkthroughs.…

  13. Deposition Measurements in NSTX

    Science.gov (United States)

    Skinner, C. H.; Kugel, H. W.; Hogan, J. T.; Wampler, W. R.

    2004-11-01

    Two quartz microbalances have been used to record deposition on the National Spherical Torus Experiment. The experimental configuration mimics a typical diagnostic window or mirror. An RS232 link was used to acquire the quartz crystal frequency and the deposited thickness was recorded continuously with 0.01 nm resolution. Nuclear Reaction Analysis of the deposit was consistent with the measurement of the total deposited mass from the change in crystal frequency. We will present measurements of the variation of deposition with plasma conditions. The transport of carbon impurities in NSTX has been modelled with the BBQ code. Preliminary calculations indicated a negligible fraction of carbon generated at the divertor plates in quiescent discharges directly reaches the outer wall, and that transient events are responsible for the deposition.

  14. Measuring domestic water use

    DEFF Research Database (Denmark)

    Tamason, Charlotte C.; Bessias, Sophia; Villada, Adriana

    2016-01-01

    Objective: To present a systematic review of methods for measuring domestic water use in settings where water meters cannot be used. Methods: We systematically searched EMBASE, PubMed, Water Intelligence Online, Water Engineering and Development Center, IEEExplore, Scielo, and Science Direct...... databases for articles that reported methodologies for measuring water use at the household level where water metering infrastructure was absent or incomplete. A narrative review explored similarities and differences between the included studies and provide recommendations for future research in water use....... Results: A total of 21 studies were included in the review. Methods ranged from single-day to 14-consecutive-day visits, and water use recall ranged from 12 h to 7 days. Data were collected using questionnaires, observations or both. Many studies only collected information on water that was carried...

  15. Photothermal measurements of superconductors

    International Nuclear Information System (INIS)

    Kino, G.S.; Wu, X.D.; Kapitulnik, A.; Fishman, I.

    1993-01-01

    The authors have developed a new photothermal technique to investigate electronic phase transitions of high temperature superconductors. The phase shift of the thermal wave yields the anisotropic thermal diffusivity coefficient of the sample. The amplitude of the photothermal signal is sensitive to electronic phase transitions of the second kind. The technique is completely noncontacting and nondestructive, and is well suited to measure small and fragile single-crystal high-T c superconductors. The measurements give good agreement with fluctuation theory near the transition temperature. They have studied diffusion in, and superconducting fluctuations of, single crystals of YBa 2 Cu 3 O 7-δ and Bi 2 Sr 2 CaCu 2 O 8 . Both systems show fluctuation effects beyond Gaussian fluctuations. While YBa 2 Cu 3 O 7-δ behaves as a three-dimensional anisotropic superconductor, results on Bi 2 Sr 2 CaCu 2 O 8 indicate strong two-dimensional effects

  16. Coating thickness measuring device

    International Nuclear Information System (INIS)

    Joffe, B.B.; Sawyer, B.E.; Spongr, J.J.

    1984-01-01

    A device especially adapted for measuring the thickness of coatings on small, complexly-shaped parts, such as, for example, electronic connectors, electronic contacts, or the like. The device includes a source of beta radiation and a radiation detector whereby backscatter of the radiation from the coated part can be detected and the thickness of the coating ascertained. The radiation source and detector are positioned in overlying relationship to the coated part and a microscope is provided to accurately position the device with respect to the part. Means are provided to control the rate of descent of the radiation source and radiation detector from its suspended position to its operating position and the resulting impact it makes with the coated part to thereby promote uniformity of readings from operator to operator, and also to avoid excessive impact with the part, thereby improving accuracy of measurement and eliminating damage to the parts

  17. External Measures of Cognition

    Directory of Open Access Journals (Sweden)

    Osvaldo eCairo

    2011-10-01

    Full Text Available The human brain is undoubtedly the most impressive, complex and intricate organ that has evolved over time. It is also probably the least understood, and for that reason, the one that is currently attracting the most attention. In fact, the number of comparative analyses that focus on the evolution of brain size in Homo sapiens and other species has increased dramatically in recent years. In neuroscience, no other issue has generated so much interest and been the topic of so many heated debates as the difference in brain size between socially defined population groups, both its connotations and implications. For over a century, external measures of cognition have been related to intelligence. However, it is still unclear whether these measures actually correspond to cognitive abilities. In summary, this paper must be reviewed with this premise in mind.

  18. Measuring Idiosyncratic Risk

    DEFF Research Database (Denmark)

    Sunesen, Eva Rytter

    This paper offers two refinements of the traditional risk measure based on the volatility of growth. First, we condition GDP growth on structural characteristics of the host country that move only slowly and therefore can be partly predicted by an investor. Second, we adjust conditional risk...... for the systematic components due to the global and regional interdependence between alternative investment locations. The decomposition of conditional risk into its systematic and idiosyncratic components reveals that not only are African countries on average characterised by a larger conditional risk than Asian...... and Latin American countries, but the idiosyncratic risk factor also represents a larger share than in other developing countries. As a final contribution, we search the empirical literature on foreign direct investment and risk in order to determine which of the suggested risk measures provide the best...

  19. Measurement by phase severance

    International Nuclear Information System (INIS)

    Noyes, H.P.

    1987-03-01

    It is claimed that the measurement process is more accurately described by ''quasi-local phase severance'' than by ''wave function collapse''. The approach starts from the observation that the usual route to quantum mechanics starting from the Hamilton-Jacobi equations throws away half the degrees of freedom, namely, the classical initial state parameters. To overcome this difficulty, the full set of Hamilton-Jacobi equations is interpreted as operator equations acting on a state vector. The measurement theory presented is based on the conventional S-matrix boundary condition of N/sub A/ free particles in the distant past and N/sub B/ free particles in the distant future and taking the usual free particle wave functions, multiplied by phase factors

  20. Three measures of longevity

    DEFF Research Database (Denmark)

    Canudas-Romo, Vladimir

    2010-01-01

    at birth increased from a level of 44 years in Sweden in 1840 to 82 years in Japan in 2005. The record median age at death shows increasing patterns similar to those observed in life expectancy at birth. However, the record modal age at death changes very little until the second half of the twentieth......This article examines the trend over time in the measures of "typical" longevity experienced by members of a population: life expectancy at birth, and the median and modal ages at death. The article also analyzes trends in record values observed for all three measures. The record life expectancy...... time from a dominance of child mortality reductions to a dominance of adult mortality reductions, which became evident by studying trends in the record modal age at death....

  1. Measuring children's food preferences

    DEFF Research Database (Denmark)

    Olsen, Annemarie; Kildegaard, Heidi; Gabrielsen, Gorm

    2012-01-01

    The aim of this study is to investigate if children’s food preferences can be reliable measured by using pictures of foods presented on a computer screen in a conjoint layout.We investigate reproducibility (test–retest) and infer validity by comparison with traditional hedonic evaluations...... juices (tangible products), chosen to span the preference spectrum, were hedonically evaluated for appearance and taste. Finally, an actual product choice was performed by having the children choose between two buns and two juices.Results showed that the computer evaluationswith pictures of foods...... provided reproducible information about the children’s visual food preferences, which were in concordance with both hedonic measures and products choices, and can thus be considered valid....

  2. Heat flux microsensor measurements

    Science.gov (United States)

    Terrell, J. P.; Hager, J. M.; Onishi, S.; Diller, T. E.

    1992-01-01

    A thin-film heat flux sensor has been fabricated on a stainless steel substrate. The thermocouple elements of the heat flux sensor were nickel and nichrome, and the temperature resistance sensor was platinum. The completed heat flux microsensor was calibrated at the AEDC radiation facility. The gage output was linear with heat flux with no apparent temperature effect on sensitivity. The gage was used for heat flux measurements at the NASA Langley Vitiated Air Test Facility. Vitiated air was expanded to Mach 3.0 and hydrogen fuel was injected. Measurements were made on the wall of a diverging duct downstream of the injector during all stages of the hydrogen combustion tests. Because the wall and the gage were not actively cooled, the wall temperature reached over 1000 C (1900 F) during the most severe test.

  3. Why measure patient satisfaction?

    Science.gov (United States)

    Riskind, Patty; Fossey, Leslie; Brill, Kari

    2011-01-01

    A practice that consistently and continuously measures patient perceptions will be more efficient and effective in its daily operations. With pay-for-performance requirements on the horizon and consumer rating sites already publicizing impressions from physician encounters, a practice needs to know how it is performing through the eyes of the patients. Azalea Orthopedics has used patient feedback to coach its physicians on better patient communication. The Orthopaedic Institute has used patient satisfaction results to reduce wait times and measure the return on investment from its marketing efforts. Patient survey results that are put to work can enhance the efficiency and effectiveness of practice operations as well as position the practice for increased profitability.

  4. Measuring European selves

    DEFF Research Database (Denmark)

    Antalikova, Radka

    Taking the perspective of cross-cultural psychology, the current thesis sets out to investigate self in a European context. For this purpose, the thesis first thoroughly reviews the most prominent conceptualizations of self in cross-cultural psychology, specifically focusing on disentangling...... the term interdependence. Thereafter, the thesis critically examines the most common measures of self and appropriates some of these measures for use in the current empirical study. More concretely, the current study compares self-descriptions and autobiographical memories of individuals from post......-Communist Europe and Scandinavia. The study’s results exemplify participants’ interdependence, whether in the form of their relational and group self-descriptions or their autobiographical memories recalled to different interpersonal cue words. On the whole, the current thesis contributes with novel data...

  5. Measuring waste prevention.

    Science.gov (United States)

    Zorpas, Antonis A; Lasaridi, Katia

    2013-05-01

    The Waste Framework Directive (WFD-2008/98/EC) has set clear waste prevention procedures, including reporting, reviewing, monitoring and evaluating. Based on the WFD, the European Commission and will offer support to Member States on how to develop waste prevention programmes through guidelines and information sharing on best practices. Monitoring and evaluating waste prevention activities are critical, as they constitute the main tools to enable policy makers, at the national and local level, to build their strategic plans and ensure that waste prevention initiatives are effective and deliver behaviour change. However, how one can measure something that is not there, remains an important and unresolved research question. The paper reviews and attempts to evaluate the methods that are being used for measuring waste prevention and the impact of relevant implemented activities at the household level, as the available data is still limited. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. High frequency energy measurements

    International Nuclear Information System (INIS)

    Stotlar, S.C.

    1981-01-01

    High-frequency (> 100 MHz) energy measurements present special problems to the experimenter. Environment or available electronics often limit the applicability of a given detector type. The physical properties of many detectors are frequency dependent and in some cases, the physical effect employed can be frequency dependent. State-of-the-art measurements generally involve a detection scheme in association with high-speed electronics and a method of data recording. Events can be single or repetitive shot requiring real time, sampling, or digitizing data recording. Potential modification of the pulse by the detector and the associated electronics should not be overlooked. This presentation will review typical applications, methods of choosing a detector, and high-speed detectors. Special considerations and limitations of some applications and devices will be described

  7. Refractive index based measurements

    DEFF Research Database (Denmark)

    2014-01-01

    A refractive index based measurement of a property of a fluid is measured in an apparatus comprising a variable wavelength coherent light source (16), a sample chamber (12), a wavelength controller (24), a light sensor (20), a data recorder (26) and a computation apparatus (28), by - directing...... coherent light having a wavelength along an input light path, - producing scattering of said light from each of a plurality of interfaces within said apparatus including interfaces between said fluid and a surface bounding said fluid, said scattering producing an interference pattern formed by said...... scattered light, - cyclically varying the wavelength of said light in said input light path over a 1 nm to 20nm wide range of wavelengths a rate of from 10Hz to 50 KHz, - recording variation of intensity of the interfering light with change in wavelength of the light at an angle of observation...

  8. Infrared Measurement Variability Analysis.

    Science.gov (United States)

    1980-09-01

    collecting optics of the measurement system. The first equation for tile blackbody experiment has the form 4.0 pim _ Ae W ,T) r(X,D) 3.5 pm - 4.0 pm JrD2 f3.5...potential for noise reduction by identifying and reducing contributing system effects. The measurement variance ott . of an infinite population of possible...irradiance can be written 4.0 pm I r()A A+ A ) 2 4.0 X C1(, = W(XT + AT)d 3.5 pim I since c + Af =2 r +Ar I Using the two expressions juSt devclopCd

  9. Measuring mandibular ridge reduction

    International Nuclear Information System (INIS)

    Steen, W.H.A.

    1984-01-01

    This thesis investigates the mandibular reduction in height of complete denture wearers and overdenture wearers. To follow this reduction in the anterior region as well as in the lateral sections of the mandible, an accurate and reproducible measuring method is a prerequisite. A radiologic technique offers the best chance. A survey is given of the literature concerning the resorption process after the extraction of teeth. An oblique cephalometric radiographic technique is introduced as a promising method to measure mandibular ridge reduction. The reproducibility and the accuracy of the technique are determined. The reproducibility in the positioning of the mandible is improved by the introduction of a mandibular support which permits a precise repositioning of the edentulous jaw, even after long periods of investigation. (Auth.)

  10. Measurement of radioactivity

    International Nuclear Information System (INIS)

    1960-01-01

    Intensive research has been going on in many countries to remove the uncertainties and to develop and perfect the methods of measuring the absolute value of the activity of a radionuclide. The importance of this research would be obvious in the context of the rapidly growing use of radioisotopes all over the world. The use of radionuclides had increased not only in regard to the variety of applications but also in respect of the quantities involved. Until recently these uses had been confined to a few scientifically advanced countries but now they were spreading to more and more countries of the world. Development in this direction was bound to continue, and this increased the importance of improving the measuring methods. The Scientific Advisory Committee of IAEA had expressed the view that it was important to attempt a synthesis of the experience in this field gained in different countries. The Vienna symposium was meant to serve that purpose

  11. Improvements in measuring apparatus

    International Nuclear Information System (INIS)

    Casey, W.

    1976-01-01

    Measuring apparatus is described that is suitable for gauging the wall profiles of downwardly extending channels in nuclear reactors, but which is equally applicable to channels such as pipe bores and conduits in other types of plant. The apparatus comprises a probe carrying a measuring transducer giving an electrical output. The probe support may be moved stepwise along the channel along a track between end members. An electrical conductor is provided for transmitting the electrical output of the transducer to an indicator located remote from the probe. The probe support may consist of a cable attached at one end to a winding drum, and incorporating an electrical conductor connected to the transducer. Channel engaging means are provided on the probe that permits free upward movement of the probe when the latter is suspended by the cable and moves into gripping engagement with the channel wall when the tension in the cable is relaxed. (U.K.)

  12. Radiation measuring instrument

    International Nuclear Information System (INIS)

    Genrich, V.

    1985-01-01

    A highly sensitive and compactly structured radiation measuring instrument for detecting ionizing radiation, in particular for measuring dose rates and contamination. The laminar structure of the associated counter tube, using only a few, simple plastic parts and a highly elastic counter wire, makes it possible to use the simplest manufacturing techniques. The service life of the counter tube construction, which is completely and permanently sealed and filled with gas, is expected to be more than 12 years. The described counter tube can be adapted in optimal fashion to the available space in a pocket instrument if it is used in combination with a specialized high-voltage generator which is low in interference voltage and with a pulse evaluation circuit having a means of compensating for interference voltage

  13. AMOS Seeing Quality Measurements.

    Science.gov (United States)

    1976-01-01

    Measurement Atmosphere Turbulence Propagation Observatory Acoustic Sounder Maui Optical Station Astronomy Microthermal Probe TEAL BLUE Degradation...presence of the site structures. Instruments used were an acoustic sounder (to probe the altitudes of 100 to 1000 ft), fine- wire microthermal probes...responsibility during the experiment for the microthermal probes. The report itself, while compiled and edited at RADC, may be considered as coming from

  14. On convex complexity measures

    Czech Academy of Sciences Publication Activity Database

    Hrubeš, P.; Jukna, S.; Kulikov, A.; Pudlák, Pavel

    2010-01-01

    Roč. 411, 16-18 (2010), s. 1842-1854 ISSN 0304-3975 R&D Projects: GA AV ČR IAA1019401 Institutional research plan: CEZ:AV0Z10190503 Keywords : boolean formula * complexity measure * combinatorial rectangle * convexity Subject RIV: BA - General Mathematics Impact factor: 0.838, year: 2010 http://www.sciencedirect.com/science/article/pii/S0304397510000885

  15. Measuring Systemic Risk

    DEFF Research Database (Denmark)

    Acharya, Viral V.; Heje Pedersen, Lasse; Philippon, Thomas

    2017-01-01

    We present an economic model of systemic risk in which undercapitalization of the financial sector as a whole is assumed to harm the real economy, leading to a systemic risk externality. Each financial institution’s contribution to systemic risk can be measured as its systemic expected shortfall...... of components of SES to predict emerging systemic risk during the financial crisis of 2007–2009....

  16. A power measuring device

    International Nuclear Information System (INIS)

    As, R. van.

    1985-01-01

    As a part of the klystron test facility of the Dutch NIKHEF-K accelerator, a sensitive power measuring device has been built. The high-frequency power of a klystron is stored in a water-cooled dummy load. Using a microcomputer, the increase of the water temperature and the water flow rate are transformed to a digital indication of the klystron power. (Auth.)

  17. Measurement in quantum physics

    International Nuclear Information System (INIS)

    Danos, M.; Kieu, T.D.; Columbia Univ., New York, NY

    1997-01-01

    The conceptual problems in quantum mechanics - including the collapse of the wave functions, the particle-wave duality, the meaning of measurement-arise from the need to ascribe particle character to the wave function, which describes only the wave aspects. It is demonstrated that all these problems can be resolved when working instead with quantum fields, which have both wave and particle character. The predictions of quantum physics, including Bell's inequalities, remain unchanged from the standard treatments of quantum mechanics. 16 refs

  18. Uniqueness in time measurement

    International Nuclear Information System (INIS)

    Lorenzen, P.

    1981-01-01

    According to P. Janich a clock is defined as an apparatus in which a point ( hand ) is moving uniformly on a straight line ( path ). For the definition of uniformly first the scaling (as a constant ratio of velocities) is defined without clocks. Thereafter the uniqueness of the time measurement can be proved using the prove of scaling of all clocks. But the uniqueness can be defined without scaling, as it is pointed out here. (orig.) [de

  19. Geometric measure theory

    CERN Document Server

    Waerden, B

    1996-01-01

    From the reviews: "... Federer's timely and beautiful book indeed fills the need for a comprehensive treatise on geometric measure theory, and his detailed exposition leads from the foundations of the theory to the most recent discoveries. ... The author writes with a distinctive style which is both natural and powerfully economical in treating a complicated subject. This book is a major treatise in mathematics and is essential in the working library of the modern analyst." Bulletin of the London Mathematical Society.

  20. Temperature measuring device

    Energy Technology Data Exchange (ETDEWEB)

    Lauf, R.J.; Bible, D.W.; Sohns, C.W.

    1999-10-19

    Systems and methods are described for a wireless instrumented silicon wafer that can measure temperatures at various points and transmit those temperature readings to an external receiver. The device has particular utility in the processing of semiconductor wafers, where it can be used to map thermal uniformity on hot plates, cold plates, spin bowl chucks, etc. without the inconvenience of wires or the inevitable thermal perturbations attendant with them.