WorldWideScience

Sample records for spectrophotometric uv detection

  1. Validated UV-Spectrophotometric Methods for Determination of Gemifloxacin Mesylate in Pharmaceutical Tablet Dosage Forms

    Directory of Open Access Journals (Sweden)

    R. Rote Ambadas

    2010-01-01

    Full Text Available Two simple, economic and accurate UV spectrophotometric methods have been developed for determination of gemifloxacin mesylate in pharmaceutical tablet formulation. The first UV-spectrophotometric method depends upon the measurement of absorption at the wavelength 263.8 nm. In second area under curve method the wavelength range for detection was selected from 268.5-258.5 nm. Beer’s law was obeyed in the range of 2 to 12 μgmL-1 for both the methods. The proposed methods was validated statistically and applied successfully to determination of gemifloxacin mesylate in pharmaceutical formulation.

  2. Validation of HPLC and UV spectrophotometric methods for the determination of meropenem in pharmaceutical dosage form.

    Science.gov (United States)

    Mendez, Andreas S L; Steppe, Martin; Schapoval, Elfrides E S

    2003-12-04

    A high-performance liquid chromatographic method and a UV spectrophotometric method for the quantitative determination of meropenem, a highly active carbapenem antibiotic, in powder for injection were developed in present work. The parameters linearity, precision, accuracy, specificity, robustness, limit of detection and limit of quantitation were studied according to International Conference on Harmonization guidelines. Chromatography was carried out by reversed-phase technique on an RP-18 column with a mobile phase composed of 30 mM monobasic phosphate buffer and acetonitrile (90:10; v/v), adjusted to pH 3.0 with orthophosphoric acid. The UV spectrophotometric method was performed at 298 nm. The samples were prepared in water and the stability of meropenem in aqueous solution at 4 and 25 degrees C was studied. The results were satisfactory with good stability after 24 h at 4 degrees C. Statistical analysis by Student's t-test showed no significant difference between the results obtained by the two methods. The proposed methods are highly sensitive, precise and accurate and can be used for the reliable quantitation of meropenem in pharmaceutical dosage form.

  3. Development and Validation of a UV Spectrophotometric and a RP-HPLC Methods for Moexipril Hydrochloride in Pure Form and Pharmaceutical Dosage Form

    International Nuclear Information System (INIS)

    Mastiholimath, V.S.; Gupte, P.P.; Mannur, V.S.

    2012-01-01

    A simple and reliable UV spectrophotometric and high-performance liquid chromatography (HPLC) methods were developed and validated for Moexipril hydrochloride in pure form and pharmaceutical dosage form. The RP-HPLC method was developed on agilant eclipse C 18 , (150 mm x 4.6 mm, 5 μm) with a mobile phase gradient system of 60 % (methanol:acetonitrile (70:30 % v/v)) : 40 % 20 mM ammonium acetate buffer pH 4.5 (v/v) and UV spectrophotometric method was developed in phosphate buffer pH 6.8. The effluent was monitored by SPD-M20A, prominence PDA detector at 210 nm. Calibration curve was linear over the concentration range of 10-35 μg/ml and 1-9 μg/ml for RP-HPLC and UV with a regression coefficient of 0.999. For RP-HPLC method Inter-day and intra-day precision % RSD values were found to be 1.00078 % and 1.49408 % respectively. For UV method 0.73386 % to 1.44111 % for inter day 0.453864 to 1.15542 intra-day precision. Recovery of Moexipril hydrochloride was found to be in the range of 99.8538 % to 101.5614 % and 100.5297586 % to 100.6431587 % for UV and RP-HPLC respectively. The limits of detection (LOD) and quantification (LOQ) for HPLC were 0.98969 and 2.99907 μg/ml, respectively. The developed RP-HPLC and UV spectrophotometric method was successfully applied for the quantitative determination of Moexipril hydrochloride in pharmaceutical dosage. (author)

  4. UV Spectrophotometric Method for Determination of Cinitapride in Pure and its Solid Dosage Form

    Directory of Open Access Journals (Sweden)

    B. Thangabalan

    2009-01-01

    Full Text Available A new, rapid, precise, accurate and sensitive analytical method was developed for the UV spectrophotometric assay of cinitapride (CTP. The drug obeyed the Beer's law and showed good correlation. It showed absorption maxima at 260 nm in methanol. The linearity was observed between 5-40 µg mL-1. The results of analysis were validated by recovery studies. The recovery was more than 99%. The proposed method is the only method available for spectrophotometric determination of the drug. It is simple, precise, sensitive and reproducible and can be used for the routine quality control testing of the marketed formulations.

  5. Simultaneous determination of atorvastatin calcium and olmesartan medoxomil in a pharmaceutical formulation by reversed phase high-performance liquid chromatography, high-performance thin-layer chromatography, and UV spectrophotometric methods.

    Science.gov (United States)

    Soni, Hiral; Kothari, Charmy; Khatri, Deepak; Mehta, Priti

    2014-01-01

    Validated RP-HPLC, HPTLC, and UV spectrophotometric methods have been developed for the simultaneous determination of atorvastatin calcium (ATV) and olmesartan medoxomil (OLM) in a pharmaceutical formulation. The RP-HPLC separation was achieved on a Kromasil C18 column (250 x 4.6 mm, 5 microm particle size) using 0.01 M potassium dihydrogen o-phosphate (pH 4 adjusted with o-phosphoric acid)-acetonitrile (50 + 50, v/v) as the mobile phase at a flow rate of 1.5 mL/min. Quantification was achieved by UV detection at 276 nm. The HPTLC separation was achieved on precoated silica gel 60F254 plates using chloroform-methanol-acetonitrile (4 + 2+ 4, v/v/v) mobile phase. Quantification was achieved with UV detection at 276 nm. The UV-Vis spectrophotometric method was based on the simultaneous equation method that involves measurement of absorbance at two wavelengths, i.e., 255 nm (lambda max of OLM) and 246.2 nm (lambda max of ATV) in methanol. All three methods were validated as per International Conference on Harmonization guidelines. The proposed methods were simple, precise, accurate, and applicable for the simultaneous determination of ATV and OLM in a marketed formulation. The results obtained by applying the proposed methods were statistically analyzed and were found satisfactory.

  6. Outlier detection in UV/Vis spectrophotometric data

    NARCIS (Netherlands)

    Lepot, M.J.; Aubin, Jean Baptiste; Clemens, F.H.L.R.; Mašić, Alma

    2017-01-01

    UV/Vis spectrophotometers have been used to monitor water quality since the early 2000s. Calibration of these devices requires sampling campaigns to elaborate relations between recorded spectra and measured concentrations. In order to build robust calibration data sets, several spectra must be

  7. Acceptability criteria for linear dependence in validating UV-spectrophotometric methods of quantitative determination in forensic and toxicological analysis

    Directory of Open Access Journals (Sweden)

    L. Yu. Klimenko

    2014-08-01

    Full Text Available Introduction. This article is the result of authors’ research in the field of development of the approaches to validation of quantitative determination methods for purposes of forensic and toxicological analysis and devoted to the problem of acceptability criteria formation for validation parameter «linearity/calibration model». The aim of research. The purpose of this paper is to analyse the present approaches to acceptability estimation of the calibration model chosen for method description according to the requirements of the international guidances, to form the own approaches to acceptability estimation of the linear dependence when carrying out the validation of UV-spectrophotometric methods of quantitative determination for forensic and toxicological analysis. Materials and methods. UV-spectrophotometric method of doxylamine quantitative determination in blood. Results. The approaches to acceptability estimation of calibration models when carrying out the validation of bioanalytical methods is stated in international papers, namely «Guidance for Industry: Bioanalytical method validation» (U.S. FDA, 2001, «Standard Practices for Method Validation in Forensic Toxicology» (SWGTOX, 2012, «Guidance for the Validation of Analytical Methodology and Calibration of Equipment used for Testing of Illicit Drugs in Seized Materials and Biological Specimens» (UNODC, 2009 and «Guideline on validation of bioanalytical methods» (ЕМА, 2011 have been analysed. It has been suggested to be guided by domestic developments in the field of validation of analysis methods for medicines and, particularly, by the approaches to validation methods in the variant of the calibration curve method for forming the acceptability criteria of the obtained linear dependences when carrying out the validation of UV-spectrophotometric methods of quantitative determination for forensic and toxicological analysis. The choice of the method of calibration curve is

  8. Development and validation of RP-HPLC and UV-spectrophotometric methods for rapid simultaneous estimation of amlodipine and benazepril in pure and fixed dose combination

    Directory of Open Access Journals (Sweden)

    Abhi Kavathia

    2017-05-01

    Full Text Available High-performance liquid chromatographic (HPLC and UV spectrophotometric methods were developed and validated for the quantitative determination of amlodipine besylate (AM and benazepril hydrochloride (BZ. Different analytical performance parameters such as linearity, precision, accuracy, specificity, limit of detection (LOD and limit of quantification (LOQ were determined according to International Conference on Harmonization ICH Q2B guidelines. The RP-HPLC method was developed by the isocratic technique on a reversed-phase Shodex C-18 5e column. The retention time for AM and BZ was 4.43 min and 5.70 min respectively. The UV spectrophotometric determinations were performed at 237 nm and 366 nm for AM and at 237 nm for BZ. Correlation between absorbance of AM at 237 nm and 366 nm was established and based on developed correlation equation estimation of BZ at 237 nm was carried out. The linearity of the calibration curves for each analyte in the desired concentration range was good (r2 > 0.999 by both the HPLC and UV methods. The method showed good reproducibility and recovery with percent relative standard deviation less than 5%. Moreover, the accuracy and precision obtained with HPLC co-related well with the UV method which implied that UV spectroscopy can be a cheap, reliable and less time consuming alternative for chromatographic analysis. The proposed methods are highly sensitive, precise and accurate and hence successfully applied for determining the assay and in vitro dissolution of a marketed formulation.

  9. Development and Validation of UV Spectrophotometric Method For Determination of Bisoprolol Fumarate in Bulk and Pharmaceutical Dosage Forms

    Directory of Open Access Journals (Sweden)

    Shahinaz Mohammed

    2017-10-01

    Full Text Available In this study a simple, accurate and precise UV- spectrophotometric method was developed for the estimation of bisoprolol fumarate (BF in bulk and tablet dosage form. The method was based on measurement of absorbance of BF aqueous solution at 225 nm. Validation was conducted in accordance to ICH guidelines. The calibration curve was linear in the concentration range 5.0-30.0 µg/mL with correlation coefficient not less than 0.996. The limit of detection and limit of quantification were 0.22 μg/ml and 0.66 μg/ml, respectively. Intraday and intermediate precision of the developed method were reflected by the low RSD% values (1.19 and 0.854, respectively. The recovery percentage was 100.6 ± 0.6%, n=3. The proposed method was applied for the assay of BF in three different brands.

  10. Chlorine Dioxide-Iodide-Methyl Acetoacetate Oscillation Reaction Investigated by UV-Vis and Online FTIR Spectrophotometric Method

    Directory of Open Access Journals (Sweden)

    Laishun Shi

    2012-01-01

    Full Text Available In order to study the chemical oscillatory behavior and mechanism of a new chlorine dioxide-iodide ion-methyl acetoacetate reaction system, a series of experiments were done by using UV-Vis and online FTIR spectrophotometric method. The initial concentrations of methyl acetoacetate, chlorine dioxide, potassium iodide, and sulfuric acid and the pH value have great influence on the oscillation observed at wavelength of 289 nm. There is a preoscillatory or induction period, and the amplitude and the number of oscillations are associated with the initial concentration of reactants. The equations for the triiodide ion reaction rate changing with reaction time and the initial concentrations in the oscillation stage were obtained. Oscillation reaction can be accelerated by increasing temperature. The apparent activation energies in terms of the induction period and the oscillation period were 26.02 KJ/mol and 17.65 KJ/mol, respectively. The intermediates were detected by the online FTIR analysis. Based upon the experimental data in this work and in the literature, a plausible reaction mechanism was proposed for the oscillation reaction.

  11. Development of Vanadometric System for Spectrophotometric ...

    African Journals Online (AJOL)

    rugged, and compares well with some complex methods for assay of timolol maleate in ... 3-[[4-(4-morpholinyl)-1, 2, 5-thiadiazol-3-yl] oxy]- ... preparation methods, costly reagents, expertise ..... chemical characterization, UV spectrophotometric.

  12. Spectrophotometric Determination of Ezetimibe

    Directory of Open Access Journals (Sweden)

    P. Baby Sudha Lakshmi

    2010-01-01

    Full Text Available Two simple, sensitive, selective and accurate spectro-photometric methods (Method A and Method B for the determination of eztimibe in bulk drug and pharmaceutical formulations (tablets have been described. Method A and B are based on the redox/complex formation reaction of drug with 1,10-phenanthroline and hexacyano-ferrate(III in presence of ferric chloride to form coloured chromogens exhibiting λmax at 510 and 740 nm respectively. The results of analysis for the two methods have been validated statistically and by recovery studies. The results are compared with those obtained using UV spectrophotometric method in alcohol at 231.7 nm.

  13. Second derivative spectrophotometric determination of ...

    African Journals Online (AJOL)

    Hemn

    2013-11-13

    Nov 13, 2013 ... olanzapine in pharmaceutical formulation.Int.J.ChemTech. Res.2(1):756-761. Stanisz B, Paszun S, Lesniak M (2009). Validation of UV derivative spectrophotometric method for determination of benazepril hydrochloride in tablets and evaluation of its stability.ActaPoloniaePharmaceutica-Drug Research.

  14. Validated UV-spectrophotometric method for the evaluation of the efficacy of makeup remover.

    Science.gov (United States)

    Charoennit, P; Lourith, N

    2012-04-01

    A UV-spectrophotometric method for the analysis of makeup remover was developed and validated according to ICH guidelines. Three makeup removers for which the main ingredients consisted of vegetable oil (A), mineral oil and silicone (B) and mineral oil and water (C) were sampled in this study. Ethanol was the optimal solvent because it did not interfere with the maximum absorbance of the liquid foundation at 250 nm. The linearity was determined over a range of makeup concentrations from 0.540 to 1.412 mg mL⁻¹ (R² = 0.9977). The accuracy of this method was determined by analysing low, intermediate and high concentrations of the liquid foundation and gave 78.59-91.57% recoveries with a relative standard deviation of makeup remover efficacy. © 2011 The Authors. ICS © 2011 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  15. Novel and validated titrimetric method for determination of selected angiotensin-II-receptor antagonists in pharmaceutical preparations and its comparison with UV spectrophotometric determination

    Directory of Open Access Journals (Sweden)

    Shrikant H. Patil

    2012-12-01

    Full Text Available A novel and simple titrimetric method for determination of commonly used angiotensin-II-receptor antagonists (ARA-IIs is developed and validated. The direct acid base titration of four ARA-IIs, namely eprosartan mesylate, irbesartan, telmisartan and valsartan, was carried out in the mixture of ethanol:water (1:1 as solvent using standardized sodium hydroxide aqueous solution as titrant, either visually using phenolphthalein as an indicator or potentiometrically using combined pH electrode. The method was found to be accurate and precise, having relative standard deviation of less than 2% for all ARA-IIs studied. Also, it was shown that the method could be successfully applied to the assay of commercial pharmaceuticals containing the above-mentioned ARA-IIs. The validity of the method was tested by the recovery studies of standard addition to pharmaceuticals and the results were found to be satisfactory. Results obtained by this method were found to be in good agreement with those obtained by UV spectrophotometric method. For UV spectrophotometric analysis ethanol was used as a solvent and wavelength of 233 nm, 246 nm, 296 nm, and 250 nm was selected for determination of eprosartan mesylate, irbesartan, telmisartan, and valsartan respectively. The proposed titrimetric method is simple, rapid, convenient and sufficiently precise for quality control purposes. Keywords: Angiotensin-II-receptor antagonists, Titrimetric assay, UV spectrophotometry, Validation

  16. Spectrophotometric Determination of Cilostazol in Tablet Dosage Form

    African Journals Online (AJOL)

    Erah

    Purpose: To develop simple, rapid and selective spectrophotometric methods for ... Conclusion: These validated methods may be useful for routine analysis of cilostazol ... Keywords: Cilostazol tablets, UV spectrophotometry, Linear regression ...

  17. Development and Validation of UV-Visible Spectrophotometric Methods for Simultaneous Estimation of Thiocolchicoside and Dexketoprofen in Bulk and Tablet Dosage Form

    OpenAIRE

    M. T. Harde; S. B. Jadhav; D. L. Dharam; P. D. Chaudhari

    2012-01-01

    Development and validation of two simple, accurate, precise and economical UV Spectrophotometric methods for simultaneous estimation of Thiocolchicoside and Dexketoprofen in bulk and in tablet dosage form. The methods employed were Method-1 Absorbance correction method and Method-2 First order derivative spectroscopic method. In method-1 Absorbance is measured at two wavelengths 370nm at which Dexketoprofen has no absorbance and 255nm at which both the drug have considerable absorbance. In me...

  18. THE DETERMINATION OF BUPROPION HYDROCHLORIDE IN PHARMACEUTICAL DOSAGE FORMS BY ORIGINAL UV- AND SECOND DERIVATIVE UV SPECTROPHOTOMETRY, POTENTIOMETRIC AND CONDUCTOMETRIC METHODS

    Directory of Open Access Journals (Sweden)

    Duygu YENİCELİ

    2010-08-01

    Full Text Available Spectrophotometric, potentiometric and conductometric methods are developed for the determination of bupropion hydrochloride (BLIP in pharmaceutical tablets. For the first method, original UV-spectrophotometry, 252 nm was determined as the optimum wavelength and used for the determinations. For the other method, second derivative UV spectrophotometry, the absorbances were measured at 217.4 and 221.8 nm and the distance between these extremum values was determined according to peak to peak method. Two spectrophotometric methods were validated over the concentration range of 5.72 - 20.03 ug/mL. The limit of detection and limit of quantitation values of original UV-spectrophotometry were 0.75 ug/mL and 2.28 jug/mL. Also, these parameters were determined as 0.23 ug/mL and 0.68 ug/mL respectively, for the second derivative UV spectrophotometry. Developed methods were fully validated and the applicability of the methods for the determination of BUP in pharmaceuticals were demonstrated. Also, simple potentiometric and conductometric methods were developed and the applicability of these methods were demonstrated. The results of four analytical methods were compared with ANOVA test and no significant difference was found statistically. As a result, the developed methods could be proposed to the rutin content analysis to be simple, cheap, accurate, and precise

  19. Effects of UV radiation on the UV-VIS absorption spectra of the EAGLE's medium components

    International Nuclear Information System (INIS)

    Bollmann, G.; Redmann, K.

    1990-01-01

    The impact of ultraviolet light on uv/vis absorption spectra of selected individual components of the cell breeding medium according to Eagle (MEM) was investigated. The strongest alterations of light absorption were detected in L-phenylalanin, L-tyrosin and L-tryptophane. Thus, the absorption behaviour of the Eagle (MEM) medium changed post radiationem may be attributed to spectrophotometric alterations of absorption in aromatic amino acids. The results are discussed with regard to the effect on the surface charge of erythrocytes. (author)

  20. Different Spectrophotometric and Chromatographic Methods for Determination of Mepivacaine and Its Toxic Impurity.

    Science.gov (United States)

    Abdelwahab, Nada S; Fared, Nehal F; Elagawany, Mohamed; Abdelmomen, Esraa H

    2017-09-01

    Stability-indicating spectrophotometric, TLC-densitometric, and ultra-performance LC (UPLC) methods were developed for the determination of mepivacaine HCl (MEP) in the presence of its toxic impurity, 2,6-dimethylanaline (DMA). Different spectrophotometric methods were developed for the determination of MEP and DMA. In a dual-wavelength method combined with direct spectrophotometric measurement, the absorbance difference between 221.4 and 240 nm was used for MEP measurements, whereas the absorbance at 283 nm was used for measuring DMA in the binary mixture. In the second-derivative method, amplitudes at 272.2 and 232.6 nm were recorded and used for the determination of MEP and DMA, respectively. The developed TLC-densitometric method depended on chromatographic separation using silica gel 60 F254 TLC plates as a stationary phase and methanol-water-acetic acid (9 + 1 + 0.1, v/v/v) as a developing system, with UV scanning at 230 nm. The developed UPLC method depended on separation using a C18 column (250 × 4.6 mm id, 5 μm particle size) as a stationary phase and acetonitrile-water (40 + 60, v/v; pH 4 with phosphoric acid) as a mobile phase at a flow rate of 0.4 mL/min, with UV detection at 215 nm. The chromatographic run time was approximately 1 min. The proposed methods were validated with respect to International Conference on Harmonization guidelines regarding precision, accuracy, ruggedness, robustness, and specificity.

  1. Uric acid detection using uv-vis spectrometer

    Science.gov (United States)

    Norazmi, N.; Rasad, Z. R. Abdul; Mohamad, M.; Manap, H.

    2017-10-01

    The aim of this research is to detect uric acid (UA) concentration using Ultraviolet-Visible (UV-Vis) spectrometer in the Ultraviolet (UV) region. Absorption technique was proposed to detect different uric acid concentrations and its UV absorption wavelength. Current practices commonly take a lot of times or require complicated structures for the detection process. By this proposed spectroscopic technique, every concentration can be detected and interpreted into an absorbance value at a constant wavelength peak in the UV region. This is due to the chemical characteristics belong to the uric acid since it has a particular absorption cross-section, σ which can be calculated using Beer’s Lambert law formula. The detection performance was displayed using Spectrasuite sofware. It showed fast time response about 3 seconds. The experiment proved that the concentrations of uric acid were successfully detected using UV-Vis spectrometer at a constant absorption UV wavelength, 294.46 nm in a low time response. Even by an artificial sample of uric acid, it successfully displayed a close value as the ones reported with the use of the medical sample. It is applicable in the medical field and can be implemented in the future for earlier detection of abnormal concentration of uric acid.

  2. Spectrophotometric Determination of Cilostazol in Tablet Dosage Form

    African Journals Online (AJOL)

    Purpose: To develop simple, rapid and selective spectrophotometric methods for the determination of cilostazol in tablet dosage form. Methods: Cilostazol was dissolved in 50 % methanol and its absorbance was scanned by ultraviolet (UV) spectrophotometry. Both linear regression equation and standard absorptivity were ...

  3. EVALUATING THE ACCUMULATION TREND OF L-DOPA IN DARK-GERMINATED SEEDS AND SUSPENSION CULTURES OF Phaseolus vulgaris L. BY AN EFFICIENT UV-SPECTROPHOTOMETRIC METHOD

    Directory of Open Access Journals (Sweden)

    Samira Rahmani-Nezhad

    Full Text Available Seed germination and plant cell cultures provide an alternative mean for producing secondary metabolites. The present study is an attempt to evaluate the effect of seed dark germination and some elicitors and precursors on the production of L-DOPA in Phaseolus vulgaris L. Callus cultured on Murashige and Skoog medium supplemented with various concentrations of different plant growth regulators. L-DOPA produced was quantified by UV-spectrophotometric method. In this study, a user-friendly, quick, and economical UV-spectrophotometric method was described to determine L-DOPA content in extracts from 33 biotypes of Phaseolus vulgaris L. The method is based on the nitrosation of L-DOPA to form a yellow solution and then formation of a red solution by adding base which is measurable at 470 nm. According to our statistical studies, this method showed high efficiency and selectivity for quantitative determination of L-DOPA in herbal extracts from dried plant seeds, dark-germinated seeds and callus cultures. L-DOPA content in dark-germinated seeds and suspension cultures increased significantly to approximately several-fold compared to the control. The implication from this study is that elicitor treatment and precursor feeding of Phaseolus vulgaris L. can significantly improve the parkinson’s relevant L-DOPA content.

  4. Chemometrics-Assisted UV Spectrophotometric and RP-HPLC Methods for the Simultaneous Determination of Tolperisone Hydrochloride and Diclofenac Sodium in their Combined Pharmaceutical Formulation.

    Science.gov (United States)

    Gohel, Nikunj Rameshbhai; Patel, Bhavin Kiritbhai; Parmar, Vijaykumar Kunvarji

    2013-01-01

    Chemometrics-assisted UV spectrophotometric and RP-HPLC methods are presented for the simultaneous determination of tolperisone hydrochloride (TOL) and diclofenac sodium (DIC) from their combined pharmaceutical dosage form. Chemometric methods are based on principal component regression and partial least-square regression models. Two sets of standard mixtures, calibration sets, and validation sets were prepared. Both models were optimized to quantify each drug in the mixture using the information included in the UV absorption spectra of the appropriate solution in the range 241-290 nm with the intervals λ = 1 nm at 50 wavelengths. The optimized models were successfully applied to the simultaneous determination of these drugs in synthetic mixture and pharmaceutical formulation. In addition, an HPLC method was developed using a reversed-phase C18 column at ambient temperature with a mobile phase consisting of methanol:acetonitrile:water (60:30:10 v/v/v), pH-adjusted to 3.0, with UV detection at 275 nm. The methods were validated in terms of linearity, accuracy, precision, sensitivity, specificity, and robustness in the range of 3-30 μg/mL for TOL and 1-10 μg/mL for DIC. The robustness of the HPLC method was tested using an experimental design approach. The developed HPLC method, and the PCR and PLS models were used to determine the amount of TOL and DIC in tablets. The data obtained from the PCR and PLS models were not significantly different from those obtained from the HPLC method at 95% confidence limit.

  5. Spectrophotometric determination of some metal ions using hydrazones

    International Nuclear Information System (INIS)

    Mohammed, M. S.

    2000-05-01

    In this research many starting materials were prepared, like methyl salicylate and salicylic acid hydrazide from which different derivatives of hydrazones were synthesized by coupling with carbonyl compounds like benzil monoxime and benzil mono hydrazone which are prepared and others like salicylaldehyde and benzoin. The hydrazones that were synthesized are salicylaldehyde salicylic acid hydrazone, benzoin salicylic acid hydrazone, benzil mono hydrazone salicylic acid hydrazone and benzil monoxime salicylic acid hydrazone. These reagents were determined by different methods, IR spectrophotometric determination, the nitrogen content method and melting point determination. These hydrazones act as ligands for determination of some metal ions by making different coloured complexes that were prepared for eight hydrazones with eight metal ions U (VI), Fe (II), Fe (III), Co (II), V (II), Mo (VI), Ni (II) and Cu (II). These complexes were determined by ultraviolet and visible spectrophotometer (UV/VIS) to detect their absorbance and wavelengths (λ max). The two hydrazones salicylaldehyde salicylic acid-hydrazone and benzoin salicylic acid hydrazone, were selected for determination of five metal ions (Fe (II), Fe (III), U (VI), Ni (II) and Cu (II)), using two micelles sodium n-dodecyl sulphate and pyridinium hexa decyl bromide mono hydrate. Their absorbance and wavelengths were detected using UV/VIS spectrophotometer. (Author)

  6. A Spectrophotometric Method for the Determination of Ramipril in ...

    African Journals Online (AJOL)

    A Spectrophotometric Method for the Determination of Ramipril in Solid Dosage Forms. ... Tropical Journal of Pharmaceutical Research ... Methods: UV spectrophotometry was used to develop and validate a simple method for the assay of ramipril in solid dosage form at λmax of 210 nm, as per International Conference on ...

  7. Liquid chromatographic and spectrophotometric methods for the determination of erythromycin stearate and trimethoprim in tablets

    Directory of Open Access Journals (Sweden)

    Sonia T. Hassib

    2011-12-01

    Full Text Available Simple, accurate and precise reversed-phase liquid chromatographic (LC and spectrophotometric methods have been developed and validated for the determination of erythromycin stearate (ERS and trimethoprim (TMP in mixture. In LC method, chromatographic separation was achieved on a Symmetry® Waters C18 column (150 × 4.6 mm, 5 μm based on isocratic elution using a mobile phase consisting of potassium dihydrogen phosphate buffer pH (9:acetonitrile:water (25:100:50, v/v/v at a flow rate of 1.6 ml min−1 with UV detection at 210 nm for ERS and 280 nm for TMP. Besides, two spectrophotometric methods were applied after reaction with perchloric acid (12 M which gives a colored product with ERS. Then, the spectral interference between the colored product of ERS and TMP was resolved by either ratio spectra derivative spectrophotometry in the first spectrophotometric method or chemometric techniques, namely classical least-squares (CLS, principal component regression (PCR and partial least-squares regression (PLS in the second spectrophotometric method. The results were statistically compared using one-way analysis of variance (ANOVA. The methods developed were satisfactorily applied to the analysis of the pharmaceutical preparation containing the two drugs and proved to be specific and accurate for the quality control of the cited drugs in pharmaceutical dosage forms.

  8. Using Spectrophotometric Titrations To Characterize Humic Acid Reactivity at Environmental Concentrations

    International Nuclear Information System (INIS)

    Janot, N.; Benedetti, M. F.; Janot, N.; Reiller, P. E.; Korshin, G. V.

    2010-01-01

    Potentiometric titration is a common method to characterize dissolved organic matter (DOM) reactivity. Because of the sensitivity of pH electrodes, it is necessary to work with very high DOM (≥1 g/L) concentrations that are unrealistic compared to those found in natural waters (0. 1 to 100 mg/L). To obtain proton binding data for concentrations closer to environmental values, spectroscopic titration methodology is a viable alternative to traditional potentiometric titrations. Spectrophotometric titrations and UV visible spectra of a diluted solution of purified Aldrich humic acid (5 mg(DOC)/L) are used to estimate changes in proton binding moieties as function of pH and ionic strength after calculation of differential absorbance spectra variations. After electrostatic correction of spectrophotometric data, there is a linear operational correlation between spectrophotometric and potentiometric data which can be used as a transfer function between the two properties. Spectrophotometric titrations are then used to determine the changes of humic acid protonation after adsorption onto alpha-alumina. (authors)

  9. Using Spectrophotometric Titrations To Characterize Humic Acid Reactivity at Environmental Concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Janot, N.; Benedetti, M. F. [Univ Paris Diderot, Lab Geochim Eaux, UMR CNRS 7154, IPGP, F-75025 Paris 13 (France); Janot, N.; Reiller, P. E. [CE Saclay, CEA DEN DANS DPC SECR, Lab Speciat Radionucleides and Mol, F-91191 Gif Sur Yvette (France); Korshin, G. V. [Univ Washington, Dept Civil and Environm Engn, Seattle, WA 98195 (United States)

    2010-07-01

    Potentiometric titration is a common method to characterize dissolved organic matter (DOM) reactivity. Because of the sensitivity of pH electrodes, it is necessary to work with very high DOM ({>=}1 g/L) concentrations that are unrealistic compared to those found in natural waters (0. 1 to 100 mg/L). To obtain proton binding data for concentrations closer to environmental values, spectroscopic titration methodology is a viable alternative to traditional potentiometric titrations. Spectrophotometric titrations and UV visible spectra of a diluted solution of purified Aldrich humic acid (5 mg(DOC)/L) are used to estimate changes in proton binding moieties as function of pH and ionic strength after calculation of differential absorbance spectra variations. After electrostatic correction of spectrophotometric data, there is a linear operational correlation between spectrophotometric and potentiometric data which can be used as a transfer function between the two properties. Spectrophotometric titrations are then used to determine the changes of humic acid protonation after adsorption onto alpha-alumina. (authors)

  10. A fast determination of nitrate in rain and surface waters by means of UV spectrophotometry

    International Nuclear Information System (INIS)

    Slanina, J.; Lingerak, W.A.; Bergman, L.

    1976-01-01

    Organic substances are the main interference in the direct U.V. spectrophotometric determination of nitrate at 210 nm. An active carbon filter (Filopur) is therefore proposed which adsorbs all organic interferences. With this filter the U.V. spectrophotometric method gives the same results as the Na-salicylate method. The reproducibility is generally better than 5%. One determination takes 50 s. (orig.) [de

  11. Determination of Nitrite and Nitrate in Natural Waters Using Flow Injection with Spectrophotometric Detection

    International Nuclear Information System (INIS)

    Yaqoob, M.; Nabi, A.

    2013-01-01

    A simple and sensitive flow injection spectrophotometric method is reported for the room temperature determination of nitrite and nitrate based on the Griess reaction and a copperised cadmium column for reduction of nitrate. Calibration graphs were linear over the range 2 - 1000 micro g N L /sup -1/ (R2 = 0.9997 and 0.9999, n = 9) with a limit of detection (3 s.d.) of 1.0 micro g N L and relative standard deviations (n = 10) of 0.9 and 1.2% for 50 micro g N L nitrite and nitrate respectively. The sample throughput was 50 h. The effect of reagent concentrations, physical parameters (flow rate, sample volume, reaction coil and copperised cadmium column length) and the potential interferences are reported. The effect of salinity on the blank and on the determination of nitrite and nitrate are also presented. The method was applied to natural waters (rainwater, freshwater and estuarine water) and the results for nitrite + nitrate (140 - 7310 micro g N L/sup -1/) were not significantly different (95% confidence interval) from results obtained using a segmented flow analyser reference method with spectrophotometric detection. (author)

  12. Development and Validation of Eco-Friendly Liquid Chromatographic and Spectrophotometric Methods for Simultaneous Determination of Coformulated Drugs: Phenylephrine Hydrochloride and Prednisolone Acetate.

    Science.gov (United States)

    Mostafa, Nadia M; Elsayed, Ghada M; Hassan, Nagiba Y; El Mously, Dina A

    2017-11-01

    Five simple, sensitive, and eco-friendly LC and UV spectrophotometric methods have been developed for the simultaneous determination of phenylephrine hydrochloride (PHE) and prednisolone acetate (PRD) in their combined dosage form. The first method was reversed-phase (RP) LC using methanol-water-heptane-1-sulfonic acid sodium salt (75 + 25 + 0.1, v/v/w) as a mobile phase. Separation was achieved using an XSelect HSS reversed-phase C18 analytical column (250 × 4.6 mm, 5µm). The flow rate was 1.0 mL/min and UV detection was done at 230 nm. Quantification was achieved over the concentration ranges of 5-50 µg/mL for PHE and 2-90 µg/mL for PRD. Four spectrophotometric methods were proposed, namely dual wavelength, first derivative of ratio spectra, ratio difference, and mean-centering of ratio spectra. Linearity was observed in the concentration ranges of 10-120 and 5-35 µg/mL for PHE and PRD, respectively, for the spectrophotometric methods. Green solvents were used in the proposed methods because they play a vital role in the analytical methods' influence on the environment. The suggested methods were validated regarding linearity, accuracy, and precision according to the International Conference on Harmonization guidelines, with satisfactory results. These methods could be used as harmless substitutes for routine analysis of the mentioned drugs, with no interference from excipients.

  13. Development and validation of a UV-spectrophotometric method for the determination of pheniramine maleate and its stability studies

    Science.gov (United States)

    Raghu, M. S.; Basavaiah, K.; Ramesh, P. J.; Abdulrahman, Sameer A. M.; Vinay, K. B.

    2012-03-01

    A sensitive, precise, and cost-effective UV-spectrophotometric method is described for the determination of pheniramine maleate (PAM) in bulk drug and tablets. The method is based on the measurement of absorbance of a PAM solution in 0.1 N HCl at 264 nm. As per the International Conference on Harmonization (ICH) guidelines, the method was validated for linearity, accuracy, precision, limits of detection (LOD) and quantification (LOQ), and robustness and ruggedness. A linear relationship between absorbance and concentration of PAM in the range of 2-40 μg/ml with a correlation coefficient (r) of 0.9998 was obtained. The LOD and LOQ values were found to be 0.18 and 0.39 μg/ml PAM, respectively. The precision of the method was satisfactory: the value of relative standard deviation (RSD) did not exceed 3.47%. The proposed method was applied successfully to the determination of PAM in tablets with good accuracy and precision. Percentages of the label claims ranged from 101.8 to 102.01% with the standard deviation (SD) from 0.64 to 0.72%. The accuracy of the method was further ascertained by recovery studies via a standard addition procedure. In addition, the forced degradation of PAM was conducted in accordance with the ICH guidelines. Acidic and basic hydrolysis, thermal stress, peroxide, and photolytic degradation were used to assess the stability-indicating power of the method. A substantial degradation was observed during oxidative and alkaline degradations. No degradation was observed under other stress conditions.

  14. Comparison of HPLC, UV spectrophotometry and potentiometric titration methods for the determination of lumefantrine in pharmaceutical products.

    Science.gov (United States)

    da Costa César, Isabela; Nogueira, Fernando Henrique Andrade; Pianetti, Gérson Antônio

    2008-09-10

    This paper describes the development and evaluation of a HPLC, UV spectrophotometry and potentiometric titration methods to quantify lumefantrine in raw materials and tablets. HPLC analyses were carried out using a Symmetry C(18) column and a mobile phase composed of methanol and 0.05% trifluoroacetic acid (80:20), with a flow rate of 1.0ml/min and UV detection at 335nm. For the spectrophotometric analyses, methanol was used as solvent and the wavelength of 335nm was selected for the detection. Non-aqueous titration of lumefantrine was carried out using perchloric acid as titrant and glacial acetic acid/acetic anhydride as solvent. The end point was potentiometrically determined. The three evaluated methods showed to be adequate to quantify lumefantrine in raw materials, while HPLC and UV methods presented the most reliable results for the analyses of tablets.

  15. Synthesis of charge transfer complex of chloranilic acid as acceptor with p-nitroaniline as donor: Crystallographic, UV-visible spectrophotometric and antimicrobial studies

    Science.gov (United States)

    Zulkarnain; Khan, Ishaat M.; Ahmad, Afaq; Miyan, Lal; Ahmad, Musheer; Azizc, Nafe

    2017-08-01

    The charge transfer interaction between p-nitroaniline (PNA) and chloranilic (CAA) acid was studied spectrophotometrically in methanol at different temperatures within the range 298-328 K. This experimental work explores the nature of charge-transfer interactions that play a significant role in chemistry and biology. Structure of synthesized charge transfer (CT) complex was investigated by different technique such as X-ray crystallography, FTIR, 1HNMR, UV-visible spectroscopy, XRD and TGA-DTA, which indicates the presence of N+sbnd Hrbd2bd O- bond between donor and acceptor moieties. Spectrophotometric studies of CT complexes were carried out in methanol at different temperatures to estimate thermodynamic parameters such as formation constant (KCT), molar absorptivity (εCT), free energy change (ΔG), enthalpy change (ΔH), resonance energy (RN), oscillator strength (f), transition dipole moment (μEN) and interaction energy (ECT) were also calculated. The effect of temperatures on all the parameters was studied in methanol. 1:1 stoichiometric of CT-complex was ascertained by Benesi-Hildebrand plots giving straight line, which are good agreement with other analysis. Synthesized CT complex was screened for its antimicrobial activity such as antibacterial activity against two gram-positive bacteria, Staphylococcus aureus and bacillus subtilis and two gram negative bacteria Escherichia coli and pseudomonas aeruginosa, and antifungal activity against fungi Fusarium oxysporum, and Aspergillus flavus.

  16. Optimization, Validation and Application of Spectrophotometric ...

    African Journals Online (AJOL)

    ... 3Research Center of Food and Drug Evaluation, Wuhan University, Wuhan 430071, ... Methods: Spectrophotometric HMG-CoA reductase detection in male Wistar ... protein expression in various regulatory ... reagents were analytical grade.

  17. REVIEW ARTICLE: Spectrophotometric applications of digital signal processing

    Science.gov (United States)

    Morawski, Roman Z.

    2006-09-01

    Spectrophotometry is more and more often the method of choice not only in analysis of (bio)chemical substances, but also in the identification of physical properties of various objects and their classification. The applications of spectrophotometry include such diversified tasks as monitoring of optical telecommunications links, assessment of eating quality of food, forensic classification of papers, biometric identification of individuals, detection of insect infestation of seeds and classification of textiles. In all those applications, large numbers of data, generated by spectrophotometers, are processed by various digital means in order to extract measurement information. The main objective of this paper is to review the state-of-the-art methodology for digital signal processing (DSP) when applied to data provided by spectrophotometric transducers and spectrophotometers. First, a general methodology of DSP applications in spectrophotometry, based on DSP-oriented models of spectrophotometric data, is outlined. Then, the most important classes of DSP methods for processing spectrophotometric data—the methods for DSP-aided calibration of spectrophotometric instrumentation, the methods for the estimation of spectra on the basis of spectrophotometric data, the methods for the estimation of spectrum-related measurands on the basis of spectrophotometric data—are presented. Finally, the methods for preprocessing and postprocessing of spectrophotometric data are overviewed. Throughout the review, the applications of DSP are illustrated with numerous examples related to broadly understood spectrophotometry.

  18. Rapid visual and spectrophotometric nitrite detection by cyclometalated ruthenium complex.

    Science.gov (United States)

    Lo, Hoi-Shing; Lo, Ka-Wai; Yeung, Chi-Fung; Wong, Chun-Yuen

    2017-10-16

    Quantitative determination of nitrite ion (NO 2 - ) is of great importance in environmental and clinical investigations. A rapid visual and spectrophotometric assay for NO 2 - detection was developed based on a newly designed ruthenium complex, [Ru(npy)([9]aneS3)(CO)](ClO 4 ) (denoted as RuNPY; npy = 2-(1-naphthyl)pyridine, [9]aneS3 = 1,4,7-trithiacyclononane). This complex traps NO + produced in acidified NO 2 - solution, and yields observable color change within 1 min at room temperature. The assay features excellent dynamic range (1-840 μmol L -1 ) and high selectivity, and its limit of detection (0.39 μmol L -1 ) is also well below the guideline values for drinking water recommended by WHO and U.S. EPA. Practical use of this assay in tap water and human urine was successfully demonstrated. Overall, the rapidity and selectivity of this assay overcome the problems suffered by the commonly used modified Griess assays for nitrite determination. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Capillary electrophoresis hyphenated with UV-native-laser induced fluorescence detection (CE/UV-native-LIF).

    Science.gov (United States)

    Couderc, François; Ong-Meang, Varravaddheay; Poinsot, Véréna

    2017-01-01

    Native laser-induced fluorescence using UV lasers associated to CE offers now a large related literature, for now 30 years. The main works have been performed using very expensive Ar-ion lasers emitting at 257 and 275 nm. They are not affordable for routine analyses, but have numerous applications such as protein, catecholamine, and indolamine analysis. Some other lasers such as HeCd 325 nm have been used but only for few applications. Diode lasers, emitting at 266 nm, cheaper, are extensively used for the same topics, even if the obtained sensitivity is lower than the one observed using the costly UV-Ar-ion lasers. This review presents various CE or microchips applications and different UV lasers used for the excitation of native fluorescence. We showed that CE/Native UV laser induced fluorescence detection is very sensitive for detection as well as small aromatic biomolecules than proteins containing Trp and Tyr amino acids. Moreover, it is a simple way to analyze biomolecules without derivatization. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Enhanced UV light detection using wavelength-shifting properties of Silicon nanoparticles

    International Nuclear Information System (INIS)

    Magill, S.; Xie, J.; Nayfeh, M.; Fizari, M.; Malloy, J.; Maximenko, Y.; Yu, H.

    2015-01-01

    Detection of UV photons is becoming increasingly necessary with the use of noble gases and liquids in elementary particle experiments. Cerenkov light in crystals and glasses, scintillation light in neutrino, dark matter, and rare decay experiments all require sensitivity to UV photons. New sensor materials are needed that can directly detect UV photons and/or absorb UV photons and re-emit light in the visible range measurable by existing photosensors. It has been shown that silicon nanoparticles are sensitive to UV light in a wavelength range around ∼ 200 nm. UV light is absorbed and re-emitted at wavelengths in the visible range depending on the size of the nanoparticles. Initial tests of the wavelength-shifting properties of silicon nanoparticles are presented here that indicate by placing a film of nanoparticles in front of a standard visible-wavelength detecting photosensor, the response of the sensor is significantly enhanced at wavelengths < 320 nm

  1. On-line Speciation of Cr(III) and Cr(VI) by Flow Injection Analysis With Spectrophotometric Detection and Chemometrics

    DEFF Research Database (Denmark)

    Diacu, Elena; Andersen, Jens Enevold Thaulov

    2003-01-01

    A flow injection system has been developed, for on-line speciation. of Cr(III) and Cr(VI) by the Diphenylcarbazide (DPC) method with H2O2 oxidation followed by spectrophotometric detection at the 550 nm wavelength. The data thus obtained were subjected to a chemometric analysis (PLS), which showe...

  2. Electrophoresis microchip with integrated waveguides for simultaneous native UV fluorescence and absorbance detection

    DEFF Research Database (Denmark)

    Ohlsson, Pelle Daniel; Sala, Olga Ordeig; Mogensen, Klaus Bo

    2009-01-01

    Simultaneous label-free detection of UV absorbance and native UV-excited fluorescence in an electrophoresis microchip is presented. UV transparent integrated waveguides launch light at a wavelength of 254 nm from a mercury lamp along the length of a 1-mm. long detection cell. Transmitted UV light...

  3. Performance Evaluation of Monolith Based Immobilized Acetylcholinesterase Flow-Through Reactor for Copper(II Determination with Spectrophotometric Detection

    Directory of Open Access Journals (Sweden)

    Parawee Rattanakit

    2014-01-01

    Full Text Available A monolith based immobilized acetylcholinesterase (AChE flow-through reactor has been developed for the determination of copper(II using flow injection spectrophotometric system. The bioreactor was prepared inside a microcapillary column by in situ polymerization of butyl methacrylate, ethylene dimethacrylate, and 2,2-dimethoxy-1,2-diphynyletane-1-one in the presence of 1-decanol, followed by vinyl azlactone functionalization and AChE immobilization. The behavior of AChE before and after being immobilized on the monolith was evaluated by kinetic parameters from Lineweaver and Burk equation. The detection was based on measuring inhibition effect on the enzymatic activity of AChE by copper(II using Ellman’s reaction with spectrophotometric detection at 410 nm. The linear range of the calibration graph was obtained over the range of 0.02–3.00 mg L−1. The detection limit, defined as 10% inhibition (I10, was found to be 0.04 mg L−1. The repeatability was 3.35 % (n=5 for 1.00 mg L−1 of copper(II. The proposed method was applied to the determination of copper(II in natural water samples with sampling rate of 4 h−1.

  4. Spectrophotometric measurement of calcium carbonate saturation states in seawater.

    Science.gov (United States)

    Easley, Regina A; Patsavas, Mark C; Byrne, Robert H; Liu, Xuewu; Feely, Richard A; Mathis, Jeremy T

    2013-02-05

    Measurements of ocean pH and carbonate ion concentrations in the North Pacific and Arctic Oceans were used to determine calcium carbonate saturation states (Ω(CaCO(3))) from spectrophotometric methods alone. Total carbonate ion concentrations, [CO(3)(2-)](T), were for the first time at sea directly measured using Pb(II) UV absorbance spectra. The basis of the method is given by the following: [formula see text] where (CO(3))β(1) is the PbCO(3)(0) formation constant, e(i) are molar absorptivity ratios, and R = (250)A/(234)A (ratio of absorbances measured at 250 and 234 nm). On the basis of shipboard and laboratory Pb(II) data and complementary carbon-system measurements, the experimental parameters were determined to be (25 °C) the following: [formula see text]. The resulting mean difference between the shipboard spectrophotometric and conventional determinations of [CO(3)(2-)](T) was ±2.03 μmol kg(-1). The shipboard analytical precision of the Pb(II) method was ∼1.71 μmol kg(-1) (2.28%). Spectrophotometric [CO(3)(2-)](T) and pH(T) were then combined to calculate Ω(CaCO(3)). For the case of aragonite, 95% of the spectrophotometric aragonite saturation states (Ω(Aspec)) were within ±0.06 of the conventionally calculated values (Ω(Acalc)) when 0.5 ≤ Ω(A) ≤ 2.0. When Ω(A) > 2.0, 95% of the Ω(Aspec) values were within ±0.18 of Ω(Acalc). Our shipboard experience indicates that spectrophotometric determinations of [CO(3)(2-)](T) and Ω(CaCO(3)) are straightforward, fast, and precise. The method yields high-quality measurements of two important, rapidly changing aspects of ocean chemistry and offers capabilities suitable for long-term automated in situ monitoring.

  5. Multi-wavelength spectrophotometric analysis for detection of xanthochromia in cerebrospinal fluid and accuracy for the diagnosis of subarachnoid hemorrhage.

    Science.gov (United States)

    Smith, Andrew; Wu, Alan H B; Lynch, Kara L; Ko, Nerissa; Grenache, David G

    2013-09-23

    Cerebrospinal fluid (CSF) was examined for bilirubin, an important indicator for diagnosis of subarachnoid hemorrhage (SAH). A multi-wavelength (340, 415, and 460 nm) spectrophotometric assay was developed for the quantitative measurement of bilirubin in CSF, enabling the mathematical correction for absorbance of hemoglobin and proteins. Bilirubin and hemoglobin results were correlated to HPLC and a standard colorimetric assay, respectively. A subset of samples was sent for an absorbance reading at 450 nm following baseline correction. The multi-wavelength bilirubin assay was validated on 70 patients with confirmed SAH and 70 patients with neurologic symptoms who ruled out for SAH. The multi-wavelength spectrophometric assay demonstrated no interferences due to proteins (albumin) up to 30 g/l or oxyhemoglobin up to 260 mg/l. The assay limit of detection was 0.2 mg/l, linear to 20 mg/l, and CVs ranged from 1 to 6% at bilirubin concentrations of 0.84 and 2.1mg/l. The spectrophotometric assay correlated to HPLC and the colorimetric assay for bilirubin and hemoglobin, respectively. Results also correlated to the absorbance method (with removal of samples with high hemoglobin and proteins). The area under the ROC curve for diagnosis of SAH was 0.971 and 0.954 for the HPLC and spectrophotometric assay, respectively. At a cutoff of 0.2mg/l, the clinical specificity was 100% for both assays, and the clinical sensitivity was 94.3% and 88.6% for SAH for the HPLC and spectrophotometric asays, respectively. The multi-wavelength spectrophotometric assay is an objective alternative to visual inspection, HPLC, and absorbance for CSF bilirubin. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Highly Sensitive Detection of UV Radiation Using a Uranium Coordination Polymer.

    Science.gov (United States)

    Liu, Wei; Dai, Xing; Xie, Jian; Silver, Mark A; Zhang, Duo; Wang, Yanlong; Cai, Yawen; Diwu, Juan; Wang, Jian; Zhou, Ruhong; Chai, Zhifang; Wang, Shuao

    2018-02-07

    The accurate detection of UV radiation is required in a wide range of chemical industries and environmental or biological related applications. Conventional methods taking advantage of semiconductor photodetectors suffer from several drawbacks such as sophisticated synthesis and manufacturing procedure, not being able to measure the accumulated UV dosage as well as high defect density in the material. Searching for new strategies or materials serving as precise UV dosage sensor with extremely low detection limit is still highly desirable. In this work, a radiation resistant uranium coordination polymer [UO 2 (L)(DMF)] (L = 5-nitroisophthalic acid, DMF = N,N-dimethylformamide, denoted as compound 1) was successfully synthesized through mild solvothermal method and investigated as a unique UV probe with the detection limit of 2.4 × 10 -7 J. On the basis of the UV dosage dependent luminescence spectra, EPR analysis, single crystal structure investigation, and the DFT calculation, the UV-induced radical quenching mechanism was confirmed. Importantly, the generated radicals are of significant stability which offers the opportunity for measuring the accumulated UV radiation dosage. Furthermore, the powder material of compound 1 was further upgraded into membrane material without loss in luminescence intensity to investigate the real application potentials. To the best of our knowledge, compound 1 represents the most sensitive coordination polymer based UV dosage probe reported to date.

  7. Second derivative spectrophotometric determination of ...

    African Journals Online (AJOL)

    A new, simple, rapid, wide applicable range and reliable second derivative spectrophotometric method has been developed for determination of cyclophosphamide (CP) in bulk and pharmaceutical dosage forms. Calibration graph is linear in the concentration range of 25 - 200 μg/ml of CP with 10 μg/ml of detection limit and ...

  8. Determination of Modafinil in Tablet Formulation Using Three New Validated Spectrophotometric Methods

    International Nuclear Information System (INIS)

    Basniwal, P.K.; Jain, D.; Basniwal, P.K.

    2014-01-01

    In this study, three new UV spectrophotometric methods viz. linear regression equation (LRE), standard absorptivity (SA) and first order derivative (FOD) method were developed and validated for determination of modafinil in tablet form. The Beer-Lamberts law was obeyed as linear in the range of 10-50 μg/ mL and all the methods were validated for linearity, accuracy, precision and robustness. These methods were successfully applied for assay of modafinil drug content in tablets in the range of 100.20 - 100.42 %, 100.11 - 100.58 % and 100.25 - 100.34 %, respectively with acceptable standard deviation (less than two) for all the methods. The validated spectrophotometric methods may be successfully applied for assay, dissolution studies, bio-equivalence studies as well as routine analysis in pharmaceutical industries. (author)

  9. Measurement of Capsaicinoids in Chiltepin Hot Pepper: A Comparison Study between Spectrophotometric Method and High Performance Liquid Chromatography Analysis

    Directory of Open Access Journals (Sweden)

    Alberto González-Zamora

    2015-01-01

    Full Text Available Direct spectrophotometric determination of capsaicinoids content in Chiltepin pepper was investigated as a possible alternative to HPLC analysis. Capsaicinoids were extracted from Chiltepin in red ripe and green fruit with acetonitrile and evaluated quantitatively using the HPLC method with capsaicin and dihydrocapsaicin standards. Three samples of different treatment were analyzed for their capsaicinoids content successfully by these methods. HPLC-DAD revealed that capsaicin, dihydrocapsaicin, and nordihydrocapsaicin comprised up to 98% of total capsaicinoids detected. The absorbance of the diluted samples was read on a spectrophotometer at 215–300 nm and monitored at 280 nm. We report herein the comparison between traditional UV assays and HPLC-DAD methods for the determination of the molar absorptivity coefficient of capsaicin (ε280=3,410 and ε280=3,720 M−1 cm−1 and dihydrocapsaicin (ε280=4,175 and ε280=4,350 M−1 cm−1, respectively. Statistical comparisons were performed using the regression analyses (ordinary linear regression and Deming regression and Bland-Altman analysis. Comparative data for pungency was determined spectrophotometrically and by HPLC on samples ranging from 29.55 to 129 mg/g with a correlation of 0.91. These results indicate that the two methods significantly agree. The described spectrophotometric method can be routinely used for total capsaicinoids analysis and quality control in agricultural and pharmaceutical analysis.

  10. Airborne pipeline leak detection: UV or IR?

    Science.gov (United States)

    Babin, François; Gravel, Jean-François; Allard, Martin

    2016-05-01

    This paper presents a study of different approaches to the measurement of the above ground vapor plume created by the spill caused by a small 0.1 l/min (or less) leak in an underground liquid petroleum pipeline. The scenarios are those for the measurement from an airborne platform. The usual approach is that of IR absorption, but in the case of liquid petroleum products, there are drawbacks that will be discussed, especially when using alkanes to detect a leak. The optical measurements studied include UV enhanced Raman lidar, UV fluorescence lidar and IR absorption path integrated lidars. The breadboards used for testing the different approaches will be described along with the set-ups for leak simulation. Although IR absorption would intuitively be the most sensitive, it is shown that UV-Raman could be an alternative. When using the very broad alkane signature in the IR, the varying ground spectral reflectance are a problem. It is also determined that integrated path measurements are preferred, the UV enhanced Raman measurements showing that the vapor plume stays very close to the ground.

  11. Modeling systematic errors: polychromatic sources of Beer-Lambert deviations in HPLC/UV and nonchromatographic spectrophotometric assays.

    Science.gov (United States)

    Galli, C

    2001-07-01

    It is well established that the use of polychromatic radiation in spectrophotometric assays leads to excursions from the Beer-Lambert limit. This Note models the resulting systematic error as a function of assay spectral width, slope of molecular extinction coefficient, and analyte concentration. The theoretical calculations are compared with recent experimental results; a parameter is introduced which can be used to estimate the magnitude of the systematic error in both chromatographic and nonchromatographic spectrophotometric assays. It is important to realize that the polychromatic radiation employed in common laboratory equipment can yield assay errors up to approximately 4%, even at absorption levels generally considered 'safe' (i.e. absorption <1). Thus careful consideration of instrumental spectral width, analyte concentration, and slope of molecular extinction coefficient is required to ensure robust analytical methods.

  12. Flow injection methods for the determination of a-tocopherol with spectrophotometric detection

    International Nuclear Information System (INIS)

    Rishi, L.; Waseem, A.; Yaqoob, M.; Nabi, A.; Jadoon, S.

    2011-01-01

    The present paper describes flow injection procedures for a-tocopherol determination in pharmaceuticals and infant milk powder based on spectrophotometric detection. These two procedures are based on the reduction of iron(III) to iron(II) and of Mo(Vi) to Mo(V) by a-tocopherol and subsequent formation of iron(II)-o-phenanthroline, and phospho molybdenum complexes which were monitored at 510 and 695 nm respectively. Calibration graphs were linear over the concentration range of 0.21-43 mu g/mL for iron(III) and 0.25-10 mu g/mL for Mo(Vi) reduction methods respectively. The limits of detection (3s) of 0.05 and 0.1 mu g/mL with sample throughput of 30 and 50/h respectively were obtained. The relative standard deviations of 1.2- 3.8% (n = 4) was achieved in the concentration range studied. The developed methods were applied to pharmaceuticals and infant milk powders and the results obtained were compared with official method and no significant difference between these methods was observed at 95% confidence level. (author)

  13. Characterization of acid-base properties of unstable drugs using a continuous-flow system with UV-vis spectrophotometric detection.

    Science.gov (United States)

    Argemí, Anna; Saurina, Javier

    2007-08-15

    In this paper, we propose a continuous-flow system for the study of the acid-base characteristics of unstable drugs. 5-Azacytidine has been selected as a first model of unstable compound, which progressively decomposes in aqueous solutions. Besides, other compounds undergoing hydrolysis and oxidation side reactions have been also analyzed to explore the performance of the method. In comparison with conventional batch titrations, the drug decomposition can be minimized by the continuous renewal of the analyte solution. The composition of the buffer mixture is varied on-line during the process from successive changes in the flow rates of acid and basic stock solutions. As a result, the pH value of the test solution is varied in a controlled manner in the range of 1-13. Multivariate curve resolution based on alternating least squares has been used to extract relevant information concerning the acid-base properties of analytes. Results from the continuous-flow system have been compared with those obtained, using batch spectrophotometric titrations, and in the case of fast degradations, the performance of the proposed procedure has been superior.

  14. Development of an indirect spectrophotometric method for ...

    African Journals Online (AJOL)

    A simple and rapid indirect spectrophotometric method for determination of ... of the colored product was measured at 405 nm and pH 3 against a reagent blank. ... The limit of detection and quantification were found to be 0.20±0.03 and ...

  15. An Electrochromatography Chip with Integrated Waveguides for UV Absorbance Detection

    DEFF Research Database (Denmark)

    Gustafsson, Omar; Mogensen, Klaus Bo; Ohlsson, Pelle Daniel

    2008-01-01

    A silicon-based microchip for electrochromatographic separations is presented. Apart from a microfluidic network, the microchip has integrated UV-transparent waveguides for detection and integrated couplers for optical fibers on the chip, yielding the most complete chromatography microchip to date...... to the waveguides. The entire oxidized silicon microchip structure is sealed with a glass lid. Reversed phase electrochromatographic separation of three neutral compounds is demonstrated using UV absorbance detection at 254 nm. Baseline separation of the analytes is achieved in less than two minutes....

  16. Detection of Fish Bones in Cod Fillets by UV Illumination.

    Science.gov (United States)

    Wang, Sheng; Nian, Rui; Cao, Limin; Sui, Jianxin; Lin, Hong

    2015-07-01

    The presence of fish bones is now regarded as an important hazard in fishery products, and there is increasing demand for new analytical techniques to control it more effectively. Here, the fluorescent properties of cod bones under UV illumination were investigated, and the maximal wavelengths for excitation and emission were determined to be 320 nm and 515 nm, respectively, demonstrating significantly different fluorescence characteristics and much higher fluorescence intensity compared to those of fillet muscles. Based on the results, UV fluorescence-assisted candling for the detection of bones in fishery products was developed for the first time. Using cod fillets as samples, the detection ratio of this technique was calculated as 90.86%, significantly higher than that of traditional candling under daylight (76.78%). Moreover, the working efficiency of the new technique was about 26% higher than that of the traditional method. A UV fluorescence imaging framework was also developed, and a method for automatic identification of the fish bones in the cod fillets based on the linear discriminant analysis proposed by Fisher was preliminarily realized, but the detection ratio was demonstrated to be relatively poor compared to those of candling techniques. These results allow us to suggest UV-based methods as new and promising approaches for routine monitoring of bones in fishery products.

  17. Effects of Vinification Techniques Combined with UV-C Irradiation on Phenolic Contents of Red Wines.

    Science.gov (United States)

    Tahmaz, Hande; Söylemezoğlu, Gökhan

    2017-06-01

    Red wines are typically high in phenolic and antioxidant capacity and both of which can be increased by vinification techniques. This study employed 3 vinification techniques to assess the increase in phenolic compounds and antioxidant capacity. Wines were obtained from Boğazkere grape cultivar by techniques of classical maceration, cold maceration combined with ultraviolet light (UV) irradiation, and thermovinification combined with UV irradiation and changes in phenolic contents were examined. Total phenolic and anthocyanin contents and trolox equivalent antioxidant capacity of wines were measured spectrophotometrically and phenolic contents (+)-catechin, (-)-epicatechin, rutin, quercetin, trans-resveratrol, and cis-resveratrol were measured by High Pressure Liquid Chromatography with Diode Array Detection (HPLC-DAD). As a result of the study, the highest phenolic content except for quercetin was measured in the wines obtained by thermovinification combined with UV irradiation. We demonstrated that the highest phenolic compounds with health effect, total phenolic compounds, total anthocyanin, and antioxidant activity were obtained from thermovinification with UV-C treatment than classical wine making. © 2017 Institute of Food Technologists®.

  18. Design of autotrack detecting instrument for solar UV radiation

    Science.gov (United States)

    Xia, Jiangtao; Mao, Xiaoli; Zhao, Jing

    2009-11-01

    In order to autotrack the object and detect the solar UV index, a reliable real-time high-precise instrument is proposed in this paper. This instrument involves two subsystems: the autotrack and detecting modules. The autotrack module consists of four-quadrant photo detector, multi-channel signal processing circuit and precise stepping system. The detecting module designed for dada measurement and acquisition is made up of the ultraviolet sensor UV460 and high precision A/D converter MAX1162. The key component of the entire instrument is ultralow-power microprocessor MSP430 which is used for entire system controlling and data processing. The lower system of autotracking and measurement is communicated with upper PC computer by RS232 module. In the experiment, the tracking precision of two-dimensional motion revolving stage is calibrated to be less than 0.05°. Experimental results indicate that the system designed could realize the precise autotracking and detecting function well, and the measure precision of system has reached the desirable target.

  19. Determination of pK(a) of felodipine using UV-Visible spectroscopy.

    Science.gov (United States)

    Pandey, M M; Jaipal, A; Kumar, A; Malik, R; Charde, S Y

    2013-11-01

    In the present study, for the first time, experimental pKa value of felodipine is reported. Dissociation constant, pKa, is one of the very important physicochemical properties of drugs. It is of paramount significance from the perspective of pharmaceutical analysis and dosage form design. The method used for the pKa determination of felodipine was essentially a UV-Visible spectrophotometric method. The spectrophotometric method for the pKa determination was opted by acknowledging the established fact that spectrophotometric determination of pKa produces most precise values. The pKa of felodipine was found to be 5.07. Furthermore, the ruggedness of the determined value is also validated in this study in order to produce exact pKa of the felodipine. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Thermo-optical Characterization of Photothermal Optical Phase Shift Detection in Extended-Nano Channels and UV Detection of Biomolecules.

    Science.gov (United States)

    Shimizu, Hisashi; Miyawaki, Naoya; Asano, Yoshihiro; Mawatari, Kazuma; Kitamori, Takehiko

    2017-06-06

    The expansion of microfluidics research to nanofluidics requires absolutely sensitive and universal detection methods. Photothermal detection, which utilizes optical absorption and nonradiative relaxation, is promising for the sensitive detection of nonlabeled biomolecules in nanofluidic channels. We have previously developed a photothermal optical phase shift (POPS) detection method to detect nonfluorescent molecules sensitively, while a rapid decrease of the sensitivity in nanochannels and the introduction of an ultraviolet (UV) excitation system were issues to be addressed. In the present study, our primary aim is to characterize the POPS signal in terms of the thermo-optical properties and quantitatively evaluate the causes for the decrease in sensitivity. The UV excitation system is then introduced into the POPS detector to realize the sensitive detection of nonlabeled biomolecules. The UV-POPS detection system is designed and constructed from scratch based on a symmetric microscope. The results of simulations and experiments reveal that the sensitivity decreases due to a reduction of the detection volume, dissipation of the heat, and cancellation of the changes in the refractive indices. Finally, determination of the concentration of a nonlabeled protein (bovine serum albumin) is performed in a very thin 900 nm deep nanochannel. As a result, the limit of detection (LOD) is 2.3 μM (600 molecules in the 440 attoliter detection volume), which is as low as that previously obtained for our visible POPS detector. UV-POPS detection is thus expected be a powerful technique for the study of biomolecules, including DNAs and proteins confined in nanofluidic channels.

  1. CATALYTIC KINETIC SPECTROPHOTOMETRIC DETERMINATION ...

    African Journals Online (AJOL)

    Preferred Customer

    acetylchlorophosphonazo(CPApA) by hydrogen peroxide in 0.10 M phosphoric acid. A novel catalytic kinetic-spectrophotometric method is proposed for the determination of copper based on this principle. Copper(II) can be determined spectrophotometrically ...

  2. Simultaneous spectrophotometric determination of trace copper, nickel, and cobalt ions in water samples using solid phase extraction coupled with partial least squares approaches

    Science.gov (United States)

    Guo, Yugao; Zhao, He; Han, Yelin; Liu, Xia; Guan, Shan; Zhang, Qingyin; Bian, Xihui

    2017-02-01

    A simultaneous spectrophotometric determination method for trace heavy metal ions based on solid-phase extraction coupled with partial least squares approaches was developed. In the proposed method, trace metal ions in aqueous samples were adsorbed by cation exchange fibers and desorbed by acidic solution from the fibers. After the ion preconcentration process, the enriched solution was detected by ultraviolet and visible spectrophotometer (UV-Vis). Then, the concentration of heavy metal ions were quantified by analyzing ultraviolet and visible spectrum with the help of partial least squares (PLS) approaches. Under the optimal conditions of operation time, flow rate and detection parameters, the overlapped absorption peaks of mixed ions were obtained. The experimental data showed that the concentration, which can be calculated through chemometrics method, of each metal ion increased significantly. The heavy metal ions can be enriched more than 80-fold. The limits of detection (LOD) for the target analytes of copper ions (Cu2 +), cobalt ions (Co2 +) and nickel ions (Ni2 +) mixture was 0.10 μg L- 1, 0.15 μg L- 1 and 0.13 μg L- 1, respectively. The relative standard deviations (RSD) were less than 5%. The performance of the solid-phase extraction can enrich the ions efficiently and the combined method of spectrophotometric detection and PLS can evaluate the ions concentration accurately. The work proposed here is an interesting and promising attempt for the trace ions determination in water samples and will have much more applied field.

  3. A new innovative spectrophotometric method for the simultaneous determination of sofosbuvir and ledipasvir

    Science.gov (United States)

    Mansour, Fotouh R.

    2018-01-01

    A new innovative spectrophotometric method is developed to determine the concentration ratios in binary mixtures by determining the zero crossing point in the first derivative of the gross curve. This relationship can be applied if the part of the UV spectrum of substance Y, that intersects with the overlaid spectra of substance X is straight. By plotting the intersection wavelength against the concentration ratio (Cx/Cy), a straight line was obtained with a co-efficient of determination equals 0.9999. As an application, simultaneous determination of sofosbuvir and ledipasvir in their binary mixtures was performed using two methods; a direct UV spectrophotometric method for determination of ledipasvir at 333 nm, and the new "wavelength-intersection ratio" method for determination of sofosbuvir. In the wavelength-intersection ratio method, different mixtures of sofosbuvir and ledipasvir containing different concentration ratios were prepared; the zero crossing point of the first derivative curve in the range 285 to 295 nm were determined for each mixture. An absorbance shift in the intersection was obtained with the change in the concentration ratio (sofosbuvir/ledipasvir). When the concentration ratio was plotted against the intersection wavelength, a straight line was obtained with a coefficient of determination of 0.9992. The direct method was linear in the range 3 to 18 μg/mL while the wavelength-intersection ratio method was linear in the range 11-110 μg/mL. The limits of detection were determined and found to be 0.5 and 3 μg/mL for ledipasvir and sofosbuvir, respectively. The accuracy and repeatability of the two methods were tested. The mean %recovery was found to be 100.19% and 100.75% for ledipasvir and sofosbuvir, respectively. The relative standard deviation was 0.57 for ledipasvir and 1.79 for sofosbuvir. The intermediate precision was also checked, the coefficients of variation for sofosbuvir and ledipasvir measurements between days did not exceed 1.88%.

  4. Spectrophotometric and Spectrofluorimetric Studies on Azilsartan Medoxomil and Chlorthalidone to be Utilized in Their Determination in Pharmaceuticals

    Directory of Open Access Journals (Sweden)

    Walid M. Ebeid

    2014-01-01

    Full Text Available The recently approved angiotensin II receptor blocker, azilsartan medoxomil (AZL, was determined spectrophotometrically and spectrofluorimetrically in its combination with chlorthalidone (CLT in their combined dosage form. The UV-spectrophotometric technique depends on simultaneous measurement of the first derivative spectra for AZL and CLT at 286 and 257 nm, respectively, in methanol. The spectrofluorimetric technique depends on measurement of the fourth derivative of the synchronous spectra intensities of AZL in presence of CLT at 298 nm in methanol. The effects of different solvents on spectrophotometric and spectrofluorimetric responses were studied. For, the spectrofluorimetric study, the effect of pH and micelle-assisted fluorescence enhancement were also studied. Linearity, accuracy, and precision were found to be satisfactory over the concentration ranges of 8-50 μg mL −1 and 2-20 μg mL −1 for AZL and CLT, respectively, in the spectrophotometric method as well as 0.01-0.08 μg mL −1 for AZL in the spectrofluorimetric method. The methods were successfully applied for the determination of the studied drugs in their co-formulated tablets. The developed methods are inexpensive and simple for the quality control and routine analysis of the cited drugs in bulk and in pharmaceuticals.

  5. Study on the Spectrophotometric Detection of Free Fatty Acids in Palm Oil Utilizing Enzymatic Reactions

    Directory of Open Access Journals (Sweden)

    Nur Hidayah Azeman

    2015-07-01

    Full Text Available In this paper, a comprehensive study has been made on the detection of free fatty acids (FFAs in palm oil via an optical technique based on enzymatic aminolysis reactions. FFAs in crude palm oil (CPO were converted into fatty hydroxamic acids (FHAs in a biphasic lipid/aqueous medium in the presence of immobilized lipase. The colored compound formed after complexation between FHA and vanadium (V ion solution was proportional to the FFA content in the CPO samples and was analyzed using a spectrophotometric method. In order to develop a rapid detection system, the parameters involved in the aminolysis process were studied. The utilization of immobilized lipase as catalyst during the aminolysis process offers simplicity in the product isolation and the possibility of conducting the process under extreme reaction conditions. A good agreement was found between the developed method using immobilized Thermomyces lanuginose lipase as catalyst for the aminolysis process and the Malaysian Palm Oil Board (MPOB standard titration method (R2 = 0.9453.

  6. [Application of HPLC-UV method for aripiprazole determination in serum].

    Science.gov (United States)

    Synowiec, Anna; Gomółka, Ewa; Zyss, Tomasz; Zieba, Andrzej; Florek, Ewa; Piekoszewski, Wojciech

    2012-01-01

    Aripiprazole is a new drug applied in schizophrenia treatment. There are not strict indications for aripiprazole therapeutic drug monitoring. Despite, serum aripiprazole measuring would help control the drug doses effectiveness. The drug monitoring can eliminate overdosing, adverse effects and let control proper drug ingestion. The aim of the paper was to develop a simple method for aripiprazole determination in serum for therapeutic drug monitoring. High performance liquid chromatography with spectrophotometric detection (HPLC-UV) was used. Resolution was performed on LC-8 column; moving phase was solution 0,025M trimethylammonium buffer: acetonitrile (62:38). Isocratic flow was 1,2 ml/min; internal standard (IS) was promazine; monitored wavelength was lambda=214 nm. The validation parameters were: limits of linearity (LOL) 100-800 ng/ml, limit of detection (LOD) 10 ng/ml, limit of quantity (LOQ) 100 ng/ml. Coefficient of variation (CV) describing accuracy and precision didn't cross 10%. The method was useful for therapeutic drug monitoring in serum of patients treated with aripiprazole.

  7. A Sensitive Validated Spectrophotometric Method for the Determination of Flucloxacillin Sodium

    Directory of Open Access Journals (Sweden)

    R. Singh Gujral

    2009-01-01

    Full Text Available A simple and sensitive spectrophotometric method has been proposed for the determination of flucloxacillin sodium. The determination method is based on charge transfer complexation reaction of the drug with iodine in methanol-dichloromethane medium. The absorbance was measured at 362 nm against the reagent blank. Under optimized experimental conditions, Beer's law is obeyed in the concentration ranges 1-9 μg/mL for flucloxacillin. The method was validated for specificity, linearity, precision, accuracy. The degree of linearity of the calibration curves, the percent recoveries, limit of detection and quantitation for the spectrophotometric method were determined. No interferences could be observed from the additives commonly present in the pharmaceutical formulations. The method was successfully applied for in vitro determination of human urine samples with low RSD value. This is simple, specific, accurate and sensitive spectrophotometric method.

  8. Detection of UV Pulse from Insulators and Application in Estimating the Conditions of Insulators

    Science.gov (United States)

    Wang, Jingang; Chong, Junlong; Yang, Jie

    2014-10-01

    Solar radiation in the band of 240-280 nm is absorbed by the ozone layer in the atmosphere, and corona discharges from high-voltage apparatus emit in air mainly in the 230-405 nm range of ultraviolet (UV), so the band of 240-280 nm is called UV Solar Blind Band. When the insulators in a string deteriorate or are contaminated, the voltage distribution along the string will change, which causes the electric fields in the vicinity of insulators change and corona discharge intensifies. An UV pulse detection method to check the conditions of insulators is presented based on detecting the UV pulse among the corona discharge, then it can be confirmed that whether there exist faulty insulators and whether the surface contamination of insulators is severe for the safe operation of power systems. An UV-I Insulator Detector has been developed, and both laboratory tests and field tests have been carried out which demonstrates the practical viability of UV-I Insulator Detector for online monitoring.

  9. Development of HPLC and UV spectrophotometric methods for the determination of ascorbic acid using hydroxypropyl-β-cyclodextrin and triethanolamine as photostabilizing agents

    International Nuclear Information System (INIS)

    Garnero, Claudia; Longhi, Marcela

    2010-01-01

    In this study, the effect of complex formation with triethanolamine (TEA) alone and in combination with hydroxypropyl-β-cyclodextrin (HP-β-CD) on the photostability of ascorbic acid was evaluated for exposure to artificial and diffuse daylight. The first-order rate constants for the photodegradation reactions were determined. The data obtained showed that these complexes strongly reduced the photodegradation process with an 11- and 35-fold increase in the photostability of ascorbic acid, depending of the ligand concentration and the irradiation source. The multicomponent complex gave a significantly better stabilization for exposure to light than TEA alone. Due to the fact that the complexation extended the exposure of ascorbic acid to light (without molecular changes), UV spectrophotometric and reversed phase high performance liquid chromatographic (HPLC) methods were developed for the quantitative determination of the vitamin in pure form and in pharmaceutical preparations. These methods were statistically validated, all the validation parameters were found to be within the acceptance range. These results demonstrate that the proposed methods are suitable for the quality control of ascorbic acid, providing simple, rapid, precise, accurate and convenient approaches for routine analysis of bulk drug and pharmaceutical formulations.

  10. An electrochromatography chip with integrated waveguides for UV absorbance detection

    International Nuclear Information System (INIS)

    Gustafsson, O; Mogensen, K B; Ohlsson, P D; Kutter, J P; Liu, Y; Jacobson, S C

    2008-01-01

    A silicon-based microchip for electrochromatographic separations is presented. Apart from a microfluidic network, the microchip has integrated UV-transparent waveguides for detection and integrated couplers for optical fibers on the chip, yielding the most complete chromatography microchip to date in terms of the integration of optical components. The microfluidic network and the optical components are fabricated in a single etching step in silicon and subsequently thermally oxidized. The separation column consists of a regular array of microfabricated solid support structures with a monolayer of an octylsilane covalently bonded to the surfaces to provide chromatographic interaction. The chip features a 1 mm long U-shaped detection cell and planar silicon dioxide waveguides that couple light to and from the detection cell. Microfabricated on-chip fiber couplers assure perfect alignment of optical fibers to the waveguides. The entire oxidized silicon microchip structure is sealed with a glass lid. Reversed phase electrochromatographic separation of three neutral compounds is demonstrated using UV absorbance detection at 254 nm. Baseline separation of the analytes is achieved in less than two minutes

  11. Spectrophotometric Analysis of Caffeine

    Directory of Open Access Journals (Sweden)

    Showkat Ahmad Bhawani

    2015-01-01

    Full Text Available The nature of caffeine reveals that it is a bitter white crystalline alkaloid. It is a common ingredient in a variety of drinks (soft and energy drinks and is also used in combination with various medicines. In order to maintain the optimum level of caffeine, various spectrophotometric methods have been developed. The monitoring of caffeine is very important aspect because of its consumption in higher doses that can lead to various physiological disorders. This paper incorporates various spectrophotometric methods used in the analysis of caffeine in various environmental samples such as pharmaceuticals, soft and energy drinks, tea, and coffee. A range of spectrophotometric methodologies including chemometric techniques and derivatization of spectra have been used to analyse the caffeine.

  12. UV-visible spectroscopy as an alternative to liquid chromatography for determination of everolimus in surfactant-containing dissolution media: a useful approach based on solid-phase extraction.

    Science.gov (United States)

    Kamberi, Marika; Tran, Thu-Ngoc

    2012-11-01

    High-throughput 96-well solid phase extraction (SPE) plate with C-18 reversed phase sorbent followed by UV-visible (UV-Vis) microplate reader was applied to the analysis of hydrophobic drugs in surfactant-containing dissolution media, which are often used to evaluate the in-vitro drug release of drug eluting stents (DES). Everolimus and dissolution medium containing Triton X-405 were selected as representatives, and the appropriate SPE conditions (adsorption, washing and elution) were investigated to obtain a practical and reliable sample clean-up. It was shown that the developed SPE procedure was capable of removing interfering components (Triton X-405 and its impurities), allowing for an accurate automated spectrophotometric analysis to be performed. The proposed UV-Vis spectrophotometric method yielded equivalent results compared to a classical LC analysis method. Linear regression analysis indicated that both methods have the ability to obtain test results that are directly proportional to the concentration of analyte in the sample within the selected range of 1.0-10 μg/ml for everolimus, with a coefficient of correlation (r(2)) value of >0.998 and standard deviation of the residuals (Syx) of UV-Vis spectrophotometric method and from 98 to 102 for the HPLC method, respectively. The 95% CI of the mean recovery for the UV-Vis spectrophotometric method was 99-102% and for the HPLC method was 99-101%. No statistical difference was found between the mean recoveries of the methods (p=0.42). Hence the methods are free from interference due to Triton and other chemicals present in the dissolution medium. The variation in the amount of everolimus estimated by UV-Vis spectrophotometric and HPLC methods was ≤3.5%, and the drug release profiles obtained by both methods were found to be equivalent by evaluation with two-one-sided t-test (two-tailed, p=0.62; mean of differences, 0.17; 95% CI, 0.62-0.96) and similarity factor f2 (f2 value, 87). The excellent conformity of

  13. Colorimetric detection of ammonia using smartphones based on localized surface plasmon resonance of silver nanoparticles.

    Science.gov (United States)

    Amirjani, Amirmostafa; Fatmehsari, Davoud Haghshenas

    2018-01-01

    In this work, a rapid and straightforward method was developed for colorimetric determination of ammonia using smartphones. The mechanisms is based on the manipulation of the surface plasmon band of silver nanoparticles (AgNPs) via the formation of Ag (NH 3 ) 2 + complex. This complex decreases the amount of AgNPs in the solution and consequently, the color intensity of the colloidal system decreases. Not only the variation in color intensity of the solution can be tracked by a UV-vis spectrophotometer, but also a smartphone can be employed to monitor the color intensity variation by RGB analysis. Ammonia, in the concentration range of 10-1000mgL -1 , was successfully measured spectrophotometrically (UV-vis spectrophotometer) and colorimetrically (RGB measurement) with the detection limit of 180 and 200mgL -1 , respectively. Linear relationships were also developed for both methods. Also, the response time of the developed colorimetric sensor was around 20s. Both of the colorimetric and spectrophotometric methods showed a reliable performance for determination of ammonia in the real samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Changes in epicuticular flavonoids and photosynthetic pigments as a plant response to UV-B radiation

    Energy Technology Data Exchange (ETDEWEB)

    Cuadra, P.; Harborne, J. B. [Universidad de Magallances, Punta Arenas (Chile)

    1996-07-01

    Treatment of Gnaphalium vira-vira plants with UV-B radiation caused changes in plant growth and in plant chemistry. The leaf surface contained two O-methylated flavones, araneol and 7-O-methylaraneol. HPLC analysis showed that 20 days of UV-B radiation increased the synthesis of 7-O-methylaraneol at the expense of araneol. Spectrophotometric analysis of the photosynthetic pigments showed that UV-B radiation also increases the pigment content in treated plants. Another U V alteration is epidermal hair damage, as observed in SEM pictures of treated leaves. This combination of physiological and phytochemical effects may be interpreted as a plant response to UV-B stress.

  15. Changes in epicuticular flavonoids and photosynthetic pigments as a plant response to UV-B radiation

    International Nuclear Information System (INIS)

    Cuadra, P.; Harborne, J.B.

    1996-01-01

    Treatment of Gnaphalium vira-vira plants with UV-B radiation caused changes in plant growth and in plant chemistry. The leaf surface contained two O-methylated flavones, araneol and 7-O-methylaraneol. HPLC analysis showed that 20 days of UV-B radiation increased the synthesis of 7-O-methylaraneol at the expense of araneol. Spectrophotometric analysis of the photosynthetic pigments showed that UV-B radiation also increases the pigment content in treated plants. Another U V alteration is epidermal hair damage, as observed in SEM pictures of treated leaves. This combination of physiological and phytochemical effects may be interpreted as a plant response to UV-B stress

  16. Spectrophotometric titration of zirconium in siliceous materials

    International Nuclear Information System (INIS)

    Sugawara, K.F.; Su, Y.-S.; Strzegowski, W.R.

    1978-01-01

    An accurate and selective complexometric titration procedure based upon a spectrophotometrically detected end-point has been developed for the determination of zirconium in glasses, glass-ceramics and refractories. A p-bromomandelic acid separation step for zirconium imparts excellent selectivity to the procedure. The method is particularly important for the 1 to 5% concentration range where a simple, accurate and selective method for the determination of zirconium has been lacking. (author)

  17. 110 1*Atkuru Veera Venkata Naga Krishna Sunil Kumar, 2Chandra ...

    African Journals Online (AJOL)

    of VDL in biological fluids. These include HPLC with amperometry detection [3], HPLC with UV detection [4], HPLC with fluorescence detection. [5], LC-MS [6,7], GC-MS [8,9] and square-wave adsorption ... stability indicating liquid chromatography with. UV detection ... in drug analysis and the spectrophotometric methods ...

  18. A multisyringe flow injection method for the determination of thorium in water samples using spectrophotometric detection

    International Nuclear Information System (INIS)

    Guzman-Mar, J.L.; Aracely Hernandez-Ramirez; Lopez-Chuken, U.J.; Lopez-de-Alba, P.L.; Victor Cerda

    2011-01-01

    A fast and simple multisyringe flow injection analysis (MSFIA) method for routine determination of thorium in water samples was developed. The methodology was based on the complexation reaction of thorium with arsenazo (III) at pH 2.0. Thorium concentrations were spectrophotometrically detected at 665 nm. Under optimal conditions, Beer's law was obeyed over the range from 0.2 to 4.5 μg mL -1 thorium, a 3σ detection limit of 0.05 μg mL -1 , and a 10σ quantification limit of 0.2 μg mL -1 were obtained. The relative standard deviations (RSD, %) at 0.5, 2.5 and 4.5 μg mL -1 was 2.8, 1.5 and 0.8%, respectively (n = 10). It was found that most of the common metal ions and anions did not interfere with the thorium determination. The proposed method was successfully applied to its analysis in various water samples. (author)

  19. Indications of Segmental Flow in Straight Pipes by Flow Injection with Spectrophotometric Detection

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    2000-01-01

    A procedure of spectrophotometric analysis of fluid flow in pipes is described and its performance is tested on three different dye compounds. The procedure follows measurement and mathematical de-convolution of the signal with an exponential function that is associated with molecular diffusion. ...

  20. Ultra-violet Spectrophotometric Determination of Caffeine in Soft and Energy Drinks Available in Yenagoa, Nigeria

    OpenAIRE

    Amos-Tautua; W. Bamidele Martin; E.R.E. Diepreye

    2014-01-01

    This study was carried out to determine the pH and levels of caffeine in eight brands of carbonated and energy drinks available in local market in Yenagoa, Nigeria. Quantitative analysis of caffeine was performed by a simple and fast standard UV spectrophotometric method, using carbon tetrachloride as the extracting solvent. Results showed that the pH of the beverages were slightly acidic ranging from 5.92-6.44. The minimum caffeine level was observed in the carbonated soft drink Coca Cola (4...

  1. The Comparison Of Silicon Analysis For The Uranium Silicide Fuel Using Spectrophotometrical And Gravimetrical Methods

    International Nuclear Information System (INIS)

    Putro, P. K.; Suripto, A.; Putra, S.; Gunanjar

    1996-01-01

    The analysis of silicon content in the uranium silicide fuel spectro-photometrical and gravimetrical method have been performed. The nitrous oxide-acetylene was used in the atomic absorption spectrophotometry (AAS) on the wave length of 251.6 nm, and the mixture of ammonium hepta molybdate complexes and SnC1 2 as reductor were applied during analysis by UV-VIS spectrophotometry (UV-VIS) on the wave length of 757.5 mm. The reagent of HCLO 4 and HNO 3 were used for determining Si content by gravimetrical methods. The results of this comparison is as follows: the accuracy result is around 96.37 % + 0.24 % for the Si concentration up to 300 ppm (the AAS), is 138.60 % = 0.43 % for the Si concentration range between 0.1-1.5 ppm (UV-VIS), and is 51.13 % + 0.8 % for 1 gram of Si (gravimetry). The results also show that the lowest analytical error is obtained by AAS method

  2. Estimation of citicoline sodium in tablets by difference spectrophotometric method

    Directory of Open Access Journals (Sweden)

    Sagar Suman Panda

    2013-01-01

    Full Text Available Aim: The present work deals with development and validation of a novel, precise, and accurate spectrophotometric method for the estimation of citicoline sodium (CTS in tablets. This spectrophotometric method is based on the principle that CTS shows two different forms that differs in the absorption spectra in basic and acidic medium. Materials and Methods: The present work was being carried out on Shimadzu 1800 Double Beam UV-visible spectrophotometer. Difference spectra were generated using 10 mm quartz cells over the range of 200-400 nm. Solvents used were 0.1 M NaOH and 0.1 M HCl. Results: The maxima and minima in the difference spectra of CTS were found to be 239 nm and 283 nm, respectively. Amplitude was calculated from the maxima and minima of spectrum. The drug follows linearity in the range of 1-50 μ/ml (R 2 = 0.999. The average % recovery from the tablet formulation was found to be 98.47%. The method was validated as per International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use: ICH Q2(R1 Validation of Analytical Procedures: Text and Methodology guidelines. Conclusion: This method is simple and inexpensive. Hence it can be applied for determination of the drug in pharmaceutical dosage forms.

  3. Enhanced UV light detection using a p-terphenyl wavelength shifter

    Science.gov (United States)

    Joosten, S.; Kaczanowicz, E.; Ungaro, M.; Rehfuss, M.; Johnston, K.; Meziani, Z.-E.

    2017-10-01

    UV-glass photomultiplier tubes (PMTs) have poor photon detection efficiency for wavelengths below 300 nm due to the opaqueness of the window material. Costly quartz PMTs could be used to enhance the efficiency below 300 nm. A less expensive solution that dramatically improves this efficiency is the application of a thin film of a p-terphenyl (PT) wavelength shifter on UV-glass PMTs. This improvement was quantified for Photonis XP4500B PMTs for wavelengths between 200 nm and 400 nm. The gain factor ranges up to 5 . 4 ± 0 . 5 at a wavelength of 215 nm, with a material load of 110 ± 10 μg /cm2 (894 nm). The wavelength shifter was found to be fully transparent for wavelengths greater than 300 nm. The resulting gain in detection efficiency, when used in a typical C̆erenkov counter, was estimated to be of the order of 40%. Consistent coating quality was assured by a rapid gain testing procedure using narrow-band UV LEDs. Based on these results, 200 Photonis XP4500B PMTs were treated with PT for the upgraded low-threshold C̆erenkov counter (LTCC) to be used in the CEBAF Large Acceptance Spectrometer upgraded detector (CLAS12) at the Thomas Jefferson National Accelerator Facility.

  4. Spectrophotometric method of the determination of gold (III) by using imipramine hydrochloride and promethazine hydrochloride

    International Nuclear Information System (INIS)

    Dembinski, B.; Kurzawa, M.; Szydlowska-Czerniak, A.

    2003-01-01

    Imipramine hydrochloride (IPM.HCl) and promethazine hydrochloride (PMT-HCl) were used for the spectrophotometric determination of gold (III) in the aqueous solution. The halides complexes of gold (III) created a coloured coupling with the studied drugs which were extractable in chloroform. These new compounds were characterized by IR,UV-VIS spectra and thermal and elemental analysis. Rapid and sensitive spectrophotometric method for the determination of gold (III) in the aqueous solution is described. The absorbance was found to be linear function of the gold (III) concentration in the range from 0.2 to 20 x10/sup -1/ mg. The ratio of complex (AuX/sub 4/) to the organic cation from drug in the obtained compounds was determined as 1:1. The method was satisfactorily applied to the analysis of gold (III). A great advantage of the proposed method is that the trace amounts of gold (III) can also be examined. (author)

  5. Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection

    Science.gov (United States)

    Aslam, Shahid; Herrero, Federico A.; Sigwarth, John; Goldsman, Neil; Akturk, Akin

    2010-01-01

    The proposed device is capable of counting ultraviolet (UV) photons, is compatible for inclusion into space instruments, and has applications as deep- UV detectors for calibration systems, curing systems, and crack detection. The device is based on a Separate Absorption and Charge Multiplication (SACM) structure. It is based on aluminum gallium nitride (AlGaN) absorber on a silicon carbide APD (avalanche photodiode). The AlGaN layer absorbs incident UV photons and injects photogenerated carriers into an underlying SiC APD that is operated in Geiger mode and provides current multiplication via avalanche breakdown. The solid-state detector is capable of sensing 100-to-365-nanometer wavelength radiation at a flux level as low as 6 photons/pixel/s. Advantages include, visible-light blindness, operation in harsh environments (e.g., high temperatures), deep-UV detection response, high gain, and Geiger mode operation at low voltage. Furthermore, the device can also be designed in array formats, e.g., linear arrays or 2D arrays (micropixels inside a superpixel).

  6. Simultaneous Spectrophotometric Determination of Valsartan and ...

    African Journals Online (AJOL)

    Purpose: To develop a direct, simple and extraction-free spectrophotometric method for the simultaneous estimation of valsartan and ezetimibe in pharmaceuticals. Methods: A spectrophotometric method for the determination of valsartan and ezetimibe was developed using acidic dyes, namely, bromophenol blue (BPB) ...

  7. Rapid and specific spectrophotometric and RP-HPLC methods for the determination of ascorbic acid in fruits juices and in human plasma

    International Nuclear Information System (INIS)

    Arayne, M.S.; Bibi, Z.; Sultana, N.

    2009-01-01

    Ascorbic acid (AA) is one of the most important water soluble vitamin in the human diet, present naturally in a wide range of foods, especially fruits and vegetables. The objective of this study was to develop a rapid, sensitive and specific method for the determination of ascorbic acid (vitamin C) from a variety of sources like fresh fruits or from human plasma using spectrophotometric technique or by RP-HPLC. Initially, estimation of vitamin C was carried out spectrophotometrically as UV spectroscopy is a trusted technique to monitor small quantities of drugs and vitamins. The assay was linear over the concentration range of 0.05-100 mi cro g/mL/sup -I/. In the second procedure, we attempted to separate and quantitate ascorbic acid from fruit juices as well as from human plasma by RP-HPLC with UV detection. This has been possible because of the diversity of columns and conditions of analysis available. Chromatographic separation was successfully achieved on a pre-packed Kromasil 100, C/sub 18/ (5 macro m 25 x 0.46) column using acetonitrile water (60:40; v/v) as mobile phase at a flow rate of 0.75 mL/sup -min/ and effluent monitored at 265 nm. The assay was also linear over the concentration range of 0.05-100 micro g/mL/sub -1/, with recovery ranging from 99.0-100.0 % and intra and inter day CV <3 % when applied to the analysis of ascorbic acid from fruit juice available in Pakistan at the time of study Grape fruit, malta, mosami, sweetlemon, fruiter, lemon, lime, custard apple, orange, lemon, guava and papaya juice were found to be very rich in as ascorbic acid, while chikoo, pear, apricot, peach, carrot and some other fruits were found to be poor sources of ascorbic acid. (author)

  8. Detecting Kerogen as a Biosignature Using Colocated UV Time-Gated Raman and Fluorescence Spectroscopy.

    Science.gov (United States)

    Shkolyar, Svetlana; Eshelman, Evan J; Farmer, Jack D; Hamilton, David; Daly, Michael G; Youngbull, Cody

    2018-04-01

    The Mars 2020 mission will analyze samples in situ and identify any that could have preserved biosignatures in ancient habitable environments for later return to Earth. Highest priority targeted samples include aqueously formed sedimentary lithologies. On Earth, such lithologies can contain fossil biosignatures as aromatic carbon (kerogen). In this study, we analyzed nonextracted kerogen in a diverse suite of natural, complex samples using colocated UV excitation (266 nm) time-gated (UV-TG) Raman and laser-induced fluorescence spectroscopies. We interrogated kerogen and its host matrix in samples to (1) explore the capabilities of UV-TG Raman and fluorescence spectroscopies for detecting kerogen in high-priority targets in the search for possible biosignatures on Mars; (2) assess the effectiveness of time gating and UV laser wavelength in reducing fluorescence in Raman spectra; and (3) identify sample-specific issues that could challenge rover-based identifications of kerogen using UV-TG Raman spectroscopy. We found that ungated UV Raman spectroscopy is suited to identify diagnostic kerogen Raman bands without interfering fluorescence and that UV fluorescence spectroscopy is suited to identify kerogen. These results highlight the value of combining colocated Raman and fluorescence spectroscopies, similar to those obtainable by SHERLOC on Mars 2020, to strengthen the confidence of kerogen detection as a potential biosignature in complex natural samples. Key Words: Raman spectroscopy-Laser-induced fluorescence spectroscopy-Mars Sample Return-Mars 2020 mission-Kerogen-Biosignatures. Astrobiology 18, 431-453.

  9. Effects of UV light and chromium ions on wood flavonoids

    International Nuclear Information System (INIS)

    Molnárné Hamvas, L.; Németh, K.; Stipta, J.

    2003-01-01

    The individual and simultaneous effect of UV light and chromium ions was investigated by spectrophotometric methods on inert surfaces impregnated with quercetin or robinetin. The UV-VIS spectra of the silica gel plates impregnated with these flavonoids were modified characteristically after irradiating ultraviolet light. Even a half an hour of irradiation has caused irreversible changes in the molecule structure. A certain chemical - presumably complexation - was concluded from the change of spectral bands assigned to flavonoids when impregnated with chromic ions. Hexavalent chromium caused more complex changes in the absorption spectra. The differences in the spectra could indicate either the oxidation and decomposition of flavonoids, or some kind of coordination process and the reduction of hexavalent chromium. The simultaneous application of UV light and chromium ions caused more pronounced effects. The complexation process between chromium(III) and flavonoid was completed

  10. Building up a database of spectro-photometric standard stars from the UV to the near-IR: A status report

    NARCIS (Netherlands)

    Vernet, J.; Kerber, F.; Saitta, F.; Mainieri, V.; D'Odorico, S.; Lidman, C.; Mason, E.; Bohlin, R.C.; Rauch, T.; Ivanov, V.D.; Smette, A.; Walsh, J.R.; Fosbury, R.A.E.; Goldoni, P.; Groot, P.; Hammer, F.; Horrobin, M.; Kaper, L.; Kjaergaard-Rasmussen, P.; Pallavicini, R.; Royer, F.

    2008-01-01

    We present a project aimed at establishing a set of 12 spectro-photometric standards over a wide wavelength range from 320 to 2500 nm. Currently no such set of standard stars covering the near-IR is available. Our strategy is to extend the useful range of existing well-established optical flux

  11. SPECTROPHOTOMETRIC DETERMINATION OF CHLOROPHYLLS AND CAROTENOIDS. AN EFFECT OF SONICATION AND SAMPLE PROCESSING

    Directory of Open Access Journals (Sweden)

    Jana Braniša

    2014-02-01

    Full Text Available Chlorophylls and carotenoids are abundant pigments in plants, algae and cyanobacteria. In this study we verified the applicability of two previously developed UV-vis spectrophotometric methods for simultaneous quantitative determination of chlorophylls (a, b and carotenoids (lycopene, β-carotene or total carotenoids. The pigments were extracted from the strawberries, apricots and raspberries in both the acetone-water and acetone-hexane mixtures. Based on the statistical evaluation of the results the combination of mechanical disruption and sonication of fruit samples seems to be a suitable way to improve the pigment extraction efficiency from fruits in both types of solvents. In the case of apricot and raspberry fruit extracts the amount of chlorophylls and carotenoids calculated from the proposed equations was comparable to those published by other authors. However, the spectrophotometric determination of β-carotene content in strawberry acetone-hexane extract appeared to be problematic mainly due to the fact that carotenoids exhibited overlapping chlorophyll absorption bands. Overlap of bands leads to the negative values calculated from the proposed equation for the β-carotene content. The results indicate the limitations in use of the proposed set of equations for plant samples with comparable amounts of studied pigments.

  12. UV Radiation Detection Using Optical Sensor Based on Eu3+ Doped PMMA

    Directory of Open Access Journals (Sweden)

    Miluski Piotr

    2016-12-01

    Full Text Available Progress in UV treatment applications requires new compact and sensor constructions. In the paper a hybrid (organic-inorganic rare-earth-based polymeric UV sensor construction is proposed. The efficient luminescence of poly(methyl methacrylate (PMMA matrix doped by europium was used for testing the optical sensor (optrode construction. The europium complex assures effective luminescence in the visible range with well determined multi-peak spectrum emission enabling construction of the optrode. The fabricated UV optical fibre sensor was used for determination of Nd:YAG laser intensity measurements at the third harmonic (355 nm in the radiation power range 5.0-34.0 mW. The multi-peak luminescence spectrum was used for optimization of the measurement formula. The composition of luminescent peak intensity enables to increase the slope of sensitivity up to −2.8 mW-1. The obtained results and advantages of the optical fibre construction enable to apply it in numerous UV detection systems.

  13. Spectrophotometric Methods for the Assay of Fluvoxamine Using Chromogenic Reagents

    Directory of Open Access Journals (Sweden)

    V. Annapurna

    2010-01-01

    Full Text Available Simple, accurate and reproducible UV-Visible spectrophotometric methods were established for the assay of FXA based on the oxidative coupling and condensation reactions. Condensation and coupling of the FXA with Ninhydrin-Ascorbic acid is proposed in method A. Method B includes complexation of FXA with cobalt thiocyanate. The ligating property of FXA with sodium nitro prusside is incorporated in method C. The optical characteristics such as Beers law limits, molar absorptivity and Sandell’s sensitivity for the methods (A-C are given. Regression analysis using the method of least squares was made to evaluate the slope(b, intercept(a and correlation coefficient (r and standard error of estimation (Se for each system. Determination of FXA in bulk form and in pharmaceutical formulations were also incorporated.

  14. Development of microwave assisted spectrophotometric method for the determination of glucose

    Science.gov (United States)

    Ali, Asif; Hussain, Zahid; Arain, Muhammad Balal; Shah, Nasrullah; Khan, Khalid Mohammad; Gulab, Hussain; Zada, Amir

    2016-01-01

    A spectrophotometric method was developed based on the microwave assisted synthesis of Maillard product. Various conditions of the reaction were optimized by varying the relative concentration of the reagents, operating temperature and volume of solutions used in the reaction in the microwave synthesizer. The absorbance of the microwave synthesized Maillard product was measured in the range of 360-740 nm using UV-Visible spectrophotometer. Based on the maximum absorbance, 370 nm was selected as the optimum wave length for further studies. The LOD and LOQ of glucose was found 3.08 μg mL- 1 and 9.33 μg mL- 1 with standard deviation of ± 0.05. The developed method was also applicable to urine sample.

  15. Study of noninvasive detection of latent fingerprints using UV laser

    Science.gov (United States)

    Li, Hong-xia; Cao, Jing; Niu, Jie-qing; Huang, Yun-gang; Mao, Lin-jie; Chen, Jing-rong

    2011-06-01

    Latent fingerprints present a considerable challenge in forensics, and noninvasive procedure that captures a digital image of the latent fingerprints is significant in the field of criminal investigation. The capability of photography technologies using 266nm UV Nd:YAG solid state laser as excitation light source to provide detailed images of unprocessed latent fingerprints is demonstrated. Unprocessed latent fingerprints were developed on various non-absorbent and absorbing substrates. According to the special absorption, reflection, scattering and fluorescence characterization of the various residues in fingerprints (fatty acid ester, protein, and carbosylic acid salts etc) to the UV light to weaken or eliminate the background disturbance and increase the brightness contrast of fingerprints with the background, and using 266nm UV laser as excitation light source, fresh and old latent fingerprints on the surface of four types of non-absorbent objects as magazine cover, glass, back of cellphone, wood desktop paintwork and two types of absorbing objects as manila envelope, notebook paper were noninvasive detected and appeared through reflection photography and fluorescence photography technologies, and the results meet the fingerprint identification requirements in forensic science.

  16. Stand-off detection of chemicals by UV Raman spectroscopy

    International Nuclear Information System (INIS)

    Wu, Ming; Ray, Mark; Hang Fung, K.; Ruckman, Mark W.; Harder, David; Sedlacek, Arthur J. III

    2000-01-01

    Experimental results are reported on a mobile, stand-alone, solar-blind ultraviolet (UV) Raman lidar system for the stand-off detection and identification of liquid and solid targets at ranges of hundreds of meters. The lidar is a coaxial system capable of performing range-resolved measurements of gases and aerosols, as well as solids and liquids. The transmitter is a flash lamp pumped 30 Hz Nd:YAG laser with quadrupled output at 266 nm. The receiver subsystem is comprised of a 40 cm Cassegrain telescope, a holographic UV edge filter for suppressing the elastic channel, a 0.46 m Czerny-Turner spectrometer, and a time gated intensified charge-coupled device (CCD) detector. The rejection of elastic light scattering by the edge filter is better than one part in 10 5 , while the transmittance 500 cm-1 to the red of the laser line is greater than 50%. Raman data are shown for selected solids, neat liquids, and mixtures down to the level of 1% volume ratio. On the basis of the strength of the Raman returns, a stand-off detection limit of ∼500 g/m2 for liquid spills of common solvents at the range of one half of a kilometer is possible. (c) 2000 Society for Applied Spectroscopy

  17. In situ, rapid, and temporally resolved measurements of cellulase adsorption onto lignocellulosic substrates by UV-vis spectrophotometry

    Science.gov (United States)

    Hao Liu; J. Y. Zhu; X. S. Chai

    2011-01-01

    This study demonstrated two in situ UV-vis spectrophotometric methods for rapid and temporally resolved measurements of cellulase adsorption onto cellulosic and lignocellulosic substrates during enzymatic hydrolysis. The cellulase protein absorption peak at 280 nm was used for quantification. The spectral interferences from light scattering by small fibers (fines) and...

  18. Regulation of the subunit composition of plastidic glutamine synthetase of the wild-type and of the phytochrome-deficient aurea mutant of tomato by blue/UV-A- or by UV-B-light

    International Nuclear Information System (INIS)

    Migge, A.; Carrayol, E.; Hirel, B.; Lohmann, M.; Meya, G.; Becker, T.W.

    1998-01-01

    The photomorphogenetic aurea mutant of tomato severely deficient in spectrophotometrically active phytochromes was used to study the light-regulation of the single-copy nuclear gene encoding plastidic glutamine synthetase (GS-2; EC 6.1.3.2). The de-etiolation of dark-grown aurea mutant seedling cotyledons showed an obligatory dependency on blue light. A limited red light-responsiveness of etiolated aurea cotyledons is, however, retained as seen by the stimulation of both the GS-2 transcript and protein level in the cotyledons of aurea seedlings during growth in red light. The subunits of the octameric GS-2 enzyme were represented by polypeptides with similar electrophoretic mobilities (polypeptides a) in etiolated wild-type or aurea mutant cotyledons. GS-2 proteins with similar apparent molecular masses were also seen in the cotyledons of red light-grown aurea mutant seedlings. In contrast, GS-2 polypeptides with different apparent molecular masses (polypeptides a and b) were detected in the cotyledons of wild-type seedlings grown in red light. This difference indicates that the (post-translational) modification of tomato GS-2 subunit composition is mediated by the photoreceptor phytochrome. The illumination of etiolated wild-type or aurea cotyledons with UV-A- or UV-B-light light resulted in an increase in both the GS-2 transcript and protein level. Following illumination of etiolated wild-type seedlings with UV-A-light, the relative proportion of the GS-2 polypeptides a and b was similar than upon irradiation with blue light but different than after exposure to UV-B- or red light. This result suggests the involvement of a blue/ UV-A-light-specific photoreceptor in the regulation of tomato GS-2 subunit composition. (author)

  19. Building-up a database of spectro-photometric standards from the UV to the NIR

    Science.gov (United States)

    Vernet, J.; Kerber, F.; Mainieri, V.; Rauch, T.; Saitta, F.; D'Odorico, S.; Bohlin, R.; Ivanov, V.; Lidman, C.; Mason, E.; Smette, A.; Walsh, J.; Fosbury, R.; Goldoni, P.; Groot, P.; Hammer, F.; Kaper, L.; Horrobin, M.; Kjaergaard-Rasmussen, P.; Royer, F.

    2010-11-01

    We present results of a project aimed at establishing a set of 12 spectro-photometric standards over a wide wavelength range from 320 to 2500 nm. Currently no such set of standard stars covering the near-IR is available. Our strategy is to extend the useful range of existing well-established optical flux standards (Oke 1990, Hamuy et al. 1992, 1994) into the near-IR by means of integral field spectroscopy with SINFONI at the VLT combined with state-of-the-art white dwarf stellar atmospheric models (TMAP, Holberg et al. 2008). As a solid reference, we use two primary HST standard white dwarfs GD71 and GD153 and one HST secondary standard BD+17 4708. The data were collected through an ESO “Observatory Programme” over ~40 nights between February 2007 and September 2008.

  20. Spectrophotometric determination of procainamide hydrochloride using sodium periodate

    OpenAIRE

    Al-Tamrah, S.; Al-Abbad, S.

    2015-01-01

    A simple spectrophotometric method has been described for the determination of procainamide hydrochloride. The method is based on the oxidation of procainamide hydrochloride by sodium periodate in the presence of sulfuric acid and measurement of the absorbance of the violet color formed at 531 nm. Parameters affecting the reaction were studied and conditions were optimized. Linear calibration graph was obtained from 50 to 700 μg ml−1 of procainamide hydrochloride and the limit of detection wa...

  1. Analysis of pharmaceutical impurities using multi-heartcutting 2D LC coupled with UV-charged aerosol MS detection.

    Science.gov (United States)

    Zhang, Kelly; Li, Yi; Tsang, Midco; Chetwyn, Nik P

    2013-09-01

    To overcome challenges in HPLC impurity analysis of pharmaceuticals, we developed an automated online multi-heartcutting 2D HPLC system with hyphenated UV-charged aerosol MS detection. The first dimension has a primary column and the second dimension has six orthogonal columns to enhance flexibility and selectivity. The two dimensions were interfaced by a pair of switching valves equipped with six trapping loops that allow multi-heartcutting of peaks of interest in the first dimension and also allow "peak parking." The hyphenated UV-charged aerosol MS detection provides comprehensive detection for compounds with and without UV chromophores, organics, and inorganics. It also provides structural information for impurity identification. A hidden degradation product that co-eluted with the drug main peak was revealed by RP × RP separation and thus enabled the stability-indicating method development. A poorly retained polar component with no UV chromophores was analyzed by RP × hydrophilic interaction liquid chromatography separation with charged aerosol detection. Furthermore, using this system, the structures of low-level impurities separated by a method using nonvolatile phosphate buffer were identified and tracked by MS in the second dimension. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Ultraviolet spectroscopy and metal ions detection

    International Nuclear Information System (INIS)

    Chaudry, M.A.

    1995-01-01

    The spectrochemical analysis is based on the interaction of radiation with the chemical species and depends on their nature, having pi, sigma or electrons, or d and f electrons, UV. Visible spectrophotometry has been used extensively in the detection and determination of both organics and inorganics. In UV detection the sensitivity is proportional to the bath length and the excitation coefficient of the given sample. It may be insensitive to many species unless these are converted to UV, absorbing derivatives. The technique has been applied for the monitoring of the effluents from HPLC, as chlorides or other complexes of various elements in this article the utility of HCl as reagent for the spectrophotometric determination of the metal ions like Al(III), As(III,IV), Ba(II), Cd(II), Ca(II) Ce(III), Cs(i), Cr(III,VI), Co(II), Cu(II), Dy(III), Eu(III), Gd(III), Au(III), Hf(IV), Ho(III), In(III), Fe(III), La(III), Pb(II), Lu (III), Mg(II), Mn(II), Hg(II), Mo(VI), Ni(II), Pd(II), Pt(IV), K(I), Pr(III), Re(VII), Ru(IV), Sm(III), Sc(III), Ag(I), Sr(II) Te(III), Th(IV), Sn(II,IV), Ti(III,IV), W(VI), U(VI), V(IV,V), Yb(III), Zn(II) AND Zr(IV) Ions i.e. for meta ions from d of the most of these metal ions has been found sufficient permit their detection in HPLC. Their molar absorptive have also been reported. Reference has also been provided to post column derivatization of some metal ions from d and f block elements for their detection in HPLC. (author) 12 figs.; 6 tabs.; 27 refs

  3. A CCD-based system for the detection of DNA in electrophoresis gels by UV absorption

    International Nuclear Information System (INIS)

    Mahon, A.R.; MacDonald, J.H.; Mainwood, A.; Ott, R.J.

    1999-01-01

    A method and apparatus for the detection and quantification of large fragments of unlabelled nucleic acids in agarose gels is presented. The technique is based on ultraviolet (UV) absorption by nucleotides. A deuterium source illuminates individual sample lanes of an electrophoresis gel via an array of optical fibres. As DNA bands pass through the illuminated region of the gel the amount of UV light transmitted is reduced because of absorption by the DNA. During electrophoresis the regions of DNA are detected on-line using a UV-sensitive charge coupled device (CCD). As the absorption coefficient is proportional to the mass of DNA the technique is inherently quantitative. The mass of DNA in a region of the gel is approximately proportional to the integrated signal in the corresponding section of the CCD image. This system currently has a detection limit of less than 1.25 ng compared with 2-10 ng for the most popular conventional technique, ethidium bromide (EtBr) staining. In addition the DNA sample remains in its native state. The removal of the carcinogenic dye from the detection procedure greatly reduces associated biological hazards. (author)

  4. Sequential capillary electrophoresis analysis using optically gated sample injection and UV/vis detection.

    Science.gov (United States)

    Liu, Xiaoxia; Tian, Miaomiao; Camara, Mohamed Amara; Guo, Liping; Yang, Li

    2015-10-01

    We present sequential CE analysis of amino acids and L-asparaginase-catalyzed enzyme reaction, by combing the on-line derivatization, optically gated (OG) injection and commercial-available UV-Vis detection. Various experimental conditions for sequential OG-UV/vis CE analysis were investigated and optimized by analyzing a standard mixture of amino acids. High reproducibility of the sequential CE analysis was demonstrated with RSD values (n = 20) of 2.23, 2.57, and 0.70% for peak heights, peak areas, and migration times, respectively, and the LOD of 5.0 μM (for asparagine) and 2.0 μM (for aspartic acid) were obtained. With the application of the OG-UV/vis CE analysis, sequential online CE enzyme assay of L-asparaginase-catalyzed enzyme reaction was carried out by automatically and continuously monitoring the substrate consumption and the product formation every 12 s from the beginning to the end of the reaction. The Michaelis constants for the reaction were obtained and were found to be in good agreement with the results of traditional off-line enzyme assays. The study demonstrated the feasibility and reliability of integrating the OG injection with UV/vis detection for sequential online CE analysis, which could be of potential value for online monitoring various chemical reaction and bioprocesses. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Spectrophotometric characterization of hemozoin as a malaria biomarker

    Science.gov (United States)

    Silva, Ivo; Lima, Rui; Minas, Graça.; Catarino, Susana O.

    2017-08-01

    Malaria is a parasitic disease with more than a billion people worldwide at risk of contraction. The disease is predominantly widespread in regions with precarious healthcare conditions and resources. Despite the several available malaria diagnostic methods, only two are predominantly used in the field in malaria-endemic countries: microscopy and rapid diagnostic tests. In this work, an alternative diagnostic system is proposed, based on optical absorption spectrophotometry. The main objective of this paper is the spectrophotometric study of hemozoin as a malaria biomarker, since it is a sub-product of the malaria infection. The optical absorbance of hemoglobin and hemozoin solutions in purified water was measured in the visible spectrum range using a spectrophotometric setup. The results showed main absorbance peaks at 540 nm and 574 nm for hemoglobin, and at 672 nm for hemozoin. The tests performed in aqueous solutions have shown that both hemoglobin and synthetic hemozoin, when alone in solution, were detected by absorbance, with sensitivity of 0.05 g/L, and with a high linearity (R2> 0.92 for all wavelength peaks). Furthermore, it was found that the whole blood and the hemoglobin spectra have similar absorption peaks. By combining whole blood and synthetic hemozoin solutions, it was proved that both the hemozoin and the hemoglobin absorbance peaks could still be detected by spectrophotometry. For instance, in polydimethylsiloxane wells, the proposed method was able to detect hemozoin in whole blood samples for optical paths as low as 3 mm in cylindrical wells, thus proving the capability for this method's miniaturization. With this work, it is possible to conclude that hemozoin is a viable candidate as a biomarker for malaria detection by optical absorption spectrophotometry and also, that an autonomous, fully integrated and low cost miniaturized system, based on such a principle, could provide an efficient diagnosis of malaria.

  6. COMPARATIVE ANALYSIS OF UV-C AND UV-B RADIATION INFLUENCE ON PLANT OBJECTS

    Directory of Open Access Journals (Sweden)

    О. Міхєєв

    2011-04-01

    Full Text Available General aim of work – comparative research of temporal regularities of growth processes of pea,that was grown under normal conditions and with application of UV-C and UV-B irradiation ofstem part, and also detection of irradiation dose relations to parameter of root and stem part sproutsgrowth rate of Aronis pea. Research subject of UV-C and UV-B irradiation influence on dynamicsof plant growth parameters in each set of experiments was alteration of growth rate, pecularities ofgrowth dynamics in different conditions of experiment, detection of UV-C and UV-B irradiationdoses range, that stimulate or inhibit growth parameters of pea sprouts. The investigation resulted indetermination 1,3 times higher efficiency of UV-V irradiation comparing to UV-B irradiation.Reaction of root didn’t depend on the type of UV-radiation

  7. Detection Range Estimation of UV Spectral Band Laser Radar

    Directory of Open Access Journals (Sweden)

    V. A. Gorodnichev

    2014-01-01

    Full Text Available Recently, has come into existence an interest in the systems operating in the ultra-violet (UF band of wavelengths, which use other spectral information (coefficients of reflection or radiation in UF range about location objects, than laser systems in the visible, near or average infrared bands. Thus, a point is not only to receive additional (in another spectral range information on location objects. Laser radiation in the UF spectral band of 0.315 – 0.4 microns is safer than laser radiation with the wavelengths of 0.38 – 1.4 microns.The work presents a comparative estimation of the detection systems range of laser radars in the UV and visible spectral bands for the following wavelengths of radiation:- UF band: 0.266 microns (the fourth harmonic of YAG-laser activated by neodymium ions, 0.308 microns (the XeCl-excimer laser, 0.355 microns (the third harmonic of YAG-laser activated by neodymium ions;- visible band: 0.532 microns (the second harmonic of YAG-laser activated by neodymium ions.Results of calculations show that for the horizontal pathway in the terrestrial atmosphere at the selected radiation wavelengths a detection range is in the range of 2510m – 5690 m.The maximum range of detection corresponds to the visible spectral band. A sweep range decreases with transition to the UF band. This is caused by the fact that with transition to the UF band there is a rise of atmosphere attenuation (generally, because of absorption by ozone, this effect being smoothed by reducing background radiation.In the UF band a wavelength of 0.355 microns is the most acceptable. For this wavelength a detection range is about 1,5 times less (in comparison with the visible band of 0.532 microns. However, this is the much more eye-safe wavelength. With transition to the UV band a detection range decreases not that much and can be compensated by changing parameters of transmitting or receiving channels of laser radar.

  8. Poling of UV-written Waveguides

    DEFF Research Database (Denmark)

    Arentoft, Jesper; Kristensen, Martin; Hübner, Jörg

    1999-01-01

    We report poling of UV-written silica waveguides. Thermal poling induces an electro-optic coefficient of 0.05 pm/V. We also demonstrate simultaneous UV-writing and UV-poling. No measurable decay in the induced electro-optic effect was detected after nine months......We report poling of UV-written silica waveguides. Thermal poling induces an electro-optic coefficient of 0.05 pm/V. We also demonstrate simultaneous UV-writing and UV-poling. No measurable decay in the induced electro-optic effect was detected after nine months...

  9. Design of simple UV Spectrophotometric and HPLC methods for assay of artesunate and amodiaquine in fixed dose tablet formulations

    International Nuclear Information System (INIS)

    Ashie, Agatha Dei

    2013-07-01

    Artesunate and Amodiaquine combination is one of the first line drugs for the treatment of uncomplicated malaria. To prevent treatment failures and emergence of resistant strains of the Plasmodium parasite, patients are entreated to comply with treatment regimens. Thus fixed dose tablet formulations came as a relieve to patients, ensuring proper compliance as the number of tablets to be taken was reduced. It is therefore important to develop simple methods of assay for these formulations to ensure that quality drugs are available and to prevent resistance to these drugs. This thesis describes Ultraviolet (UV) and High Performance Liquid Chromatographic (HPLC) methods of assay for Artesunate (AS) and Amodiaduine Hydrochloride (AMQ) in fixed dose tablet formulations. The UV absorption spectroscopy was used to establish a wavelength of maximum absorption and the Beer’s plot generated. At 339nm, Amodiaquine Hydrochloride was assayed accurately in methanol with a high r"2 value of 0.998, an intra and inter day precision of Relative Standard Deviation (RSD) of 1.52% and 1.86% respectively. The Beer’s plot was obeyed in a concentration range of 3.5 - 24.8(µg/mL). The limit of detection and limit of quantification was 1.23(µg/mL) and 3.73(µg/mL) respectively. However the UV method could not be used to assay AS simultaneously with AMQ. A mobile phase of 60% acetonitrile and 40% of 0.05% trifluoroacetic acid, flow rate of 1ml/min, wavelength of detection of 225nm and a C_1_8 stationary phase are the parameters for the HPLC method. The r"2 for the HPLC method was 0.996 and 0.995 for Amodiaquine hydrochloride and Artesunate respectively. The intra and inter day precision were 1.07% and 1.42% respectively. The limit of detection and limit of quantification were 0.015%w/v and 0.0465%w/v for Amodiaquine hydrochloride and 0.054%w/v and 0.019%w/v for Artesunate respectively. The concentration ranges were 0.01 - 0.16%w/v for Amodiaquine hydrochloride and 0.01 – 0.2%w/v for

  10. Detection of silver nanoparticles in seawater at ppb levels using UV-visible spectrophotometry with long path cells.

    Science.gov (United States)

    Lodeiro, Pablo; Achterberg, Eric P; El-Shahawi, Mohammad S

    2017-03-01

    Silver nanoparticles (AgNPs) are emerging contaminants that are difficult to detect in natural waters. UV-visible spectrophotometry is a simple technique that allows detection of AgNPs through analysis of their characteristic surface plasmon resonance band. The detection limit for nanoparticles using up to 10cm path length cuvettes with UV-visible spectrophotometry is in the 0.1-10ppm range. This detection limit is insufficiently low to observe AgNPs in natural environments. Here we show how the use of capillary cells with an optical path length up to 200cm, forms an excellent technique for rapid detection and quantification of non-aggregated AgNPs at ppb concentrations in complex natural matrices such as seawater. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. UV Absorption Spectroscopy in Water-Filled Antiresonant Hollow Core Fibers for Pharmaceutical Detection.

    Science.gov (United States)

    Nissen, Mona; Doherty, Brenda; Hamperl, Jonas; Kobelke, Jens; Weber, Karina; Henkel, Thomas; Schmidt, Markus A

    2018-02-06

    Due to a worldwide increased use of pharmaceuticals and, in particular, antibiotics, a growing number of these substance residues now contaminate natural water resources and drinking supplies. This triggers a considerable demand for low-cost, high-sensitivity methods for monitoring water quality. Since many biological substances exhibit strong and characteristic absorption features at wavelengths shorter than 300 nm, UV spectroscopy presents a suitable approach for the quantitative identification of such water-contaminating species. However, current UV spectroscopic devices often show limited light-matter interaction lengths, demand sophisticated and bulky experimental infrastructure which is not compatible with microfluidics, and leave large fractions of the sample analyte unused. Here, we introduce the concept of UV spectroscopy in liquid-filled anti-resonant hollow core fibers, with large core diameters and lengths of approximately 1 m, as a means to overcome such limitations. This extended light-matter interaction length principally improves the concentration detection limit by two orders of magnitude while using almost the entire sample volume-that is three orders of magnitude smaller compared to cuvette based approaches. By integrating the fibers into an optofluidic chip environment and operating within the lowest experimentally feasible transmission band, concentrations of the application-relevant pharmaceutical substances, sulfamethoxazole (SMX) and sodium salicylate (SS), were detectable down to 0.1 µM (26 ppb) and 0.4 µM (64 ppb), respectively, with the potential to reach significantly lower detection limits for further device integration.

  12. UV Absorption Spectroscopy in Water-Filled Antiresonant Hollow Core Fibers for Pharmaceutical Detection

    Directory of Open Access Journals (Sweden)

    Mona Nissen

    2018-02-01

    Full Text Available Due to a worldwide increased use of pharmaceuticals and, in particular, antibiotics, a growing number of these substance residues now contaminate natural water resources and drinking supplies. This triggers a considerable demand for low-cost, high-sensitivity methods for monitoring water quality. Since many biological substances exhibit strong and characteristic absorption features at wavelengths shorter than 300 nm, UV spectroscopy presents a suitable approach for the quantitative identification of such water-contaminating species. However, current UV spectroscopic devices often show limited light-matter interaction lengths, demand sophisticated and bulky experimental infrastructure which is not compatible with microfluidics, and leave large fractions of the sample analyte unused. Here, we introduce the concept of UV spectroscopy in liquid-filled anti-resonant hollow core fibers, with large core diameters and lengths of approximately 1 m, as a means to overcome such limitations. This extended light-matter interaction length principally improves the concentration detection limit by two orders of magnitude while using almost the entire sample volume—that is three orders of magnitude smaller compared to cuvette based approaches. By integrating the fibers into an optofluidic chip environment and operating within the lowest experimentally feasible transmission band, concentrations of the application-relevant pharmaceutical substances, sulfamethoxazole (SMX and sodium salicylate (SS, were detectable down to 0.1 µM (26 ppb and 0.4 µM (64 ppb, respectively, with the potential to reach significantly lower detection limits for further device integration.

  13. Spectrophotometric determination of the sulfhydryl containing drug mesna

    Directory of Open Access Journals (Sweden)

    Rim S. Haggag

    2016-06-01

    Full Text Available Four simple and sensitive spectrophotometric methods were developed for the determination of the sulfhydryl containing drug mesna (MSN. Methods I and II rely on nucleophilic aromatic substitution reactions using two UV tagging reagents namely: 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl for method I and 2,4-dinitrofluorobenzene (DNFB for method II. Both reactions took place in alkaline buffered medium and the obtained yellowish products were measured at 414 and 332 nm for methods I and II, respectively. Methods III and IV are indirect spectrophotometric methods based on the suppressive effect of MSN on the absorption of two ternary complex systems which are composed of 1,10-phenanthroline, silver and eosin for method III and 1,10-phenanthroline, silver and bromopyrogallol red for method IV. The decrease in absorbance of the ternary complexes was measured at 547 and 635 nm for methods III and IV, respectively. All the experimental parameters affecting these reactions were carefully studied and optimized. The methods were validated as per the ICH guidelines. The methods were applicable in the linearity ranges 4–18 μg/mL for method I, 4–16 μg/mL for method II, 0.25–2.25 μg/mL for method III and 0.25–1.75 μg/mL for method IV. The proposed methods were successfully applied for the analysis of MSN in its commercial ampoules and no interference was encountered from the present excipients as indicated by the satisfactory percentage recoveries. The results obtained were in a good agreement with those obtained from a previously published method of the investigated drug.

  14. Performance Analysis of Si-Based Ultra-Shallow Junction Photodiodes for UV Radiation Detection

    NARCIS (Netherlands)

    Shi, L.

    2013-01-01

    This thesis presents a performance investigation of newly-developed ultra-shallow junction photodiodes (PureB-diodes) for ultraviolet (UV) radiation detection. The photodiodes are fabricated by pure boron chemical vapor deposition (PureB CVD) technology, which can provide nanometer-thin boron

  15. Spectrophotometric Methods for Simultaneous Determination of Oxytetracycline HCl and Flunixin Meglumine in Their Veterinary Pharmaceutical Formulation

    Directory of Open Access Journals (Sweden)

    Hanan A. Merey

    2017-01-01

    Full Text Available Four precise, accurate, selective, and sensitive UV-spectrophotometric methods were developed and validated for the simultaneous determination of a binary mixture of Oxytetracycline HCl (OXY and Flunixin Meglumine (FLU. The first method, dual wavelength (DW, depends on measuring the difference in absorbance (ΔA 273.4–327 nm for the determination of OXY where FLU is zero while FLU is determined at ΔA 251.7–275.7 nm. The second method, first-derivative spectrophotometric method (1D, depends on measuring the peak amplitude of the first derivative selectively at 377 and 266.7 nm for the determination of OXY and FLU, respectively. The third method, ratio difference method, depends on the difference in amplitudes of the ratio spectra at ΔP 286.5–324.8 nm and ΔP 249.6–286.3 nm for the determination of OXY and FLU, respectively. The fourth method, first derivative of ratio spectra method (1DD, depends on measuring the amplitude peak to peak of the first derivative of ratio spectra at 296.7 to 369 nm and 259.1 to 304.7 nm for the determination of OXY and FLU, respectively. Different factors affecting the applied spectrophotometric methods were studied. The proposed methods were validated according to ICH guidelines. Satisfactory results were obtained for determination of both drugs in laboratory prepared mixture and pharmaceutical dosage form. The developed methods are compared favourably with the official ones.

  16. SHARDS: a spectro-photometric analysis of distant red and dead massive galaxies

    Science.gov (United States)

    Pérez-González, P. G.; Cava, A.; The Shards Team

    2013-05-01

    SHARDS, an ESO/GTC Large Program, is an ultra-deep (26.5 mag) spectro-photometric survey carried out with GTC/OSIRIS and designed to select and study massive passively evolving galaxies at z= 1.0--2.5 in the GOODS-N field. The survey uses a set of 24 medium band filters (FWHM ˜15 nm) covering the 500--950 nm spectral range. Our observing strategy has been planned to detect, for z>1 sources, the prominent Mg absorption feature (at rest-frame ˜280 nm), a distinctive, necessary, and sufficient feature of evolved stellar populations (older than 0.5 Gyr). These observations are being used to: (1) construct for the first time an unbiased sample of high-z quiescent galaxies, which extends to fainter magnitudes the samples selected with color techniques and spectroscopic surveys; (2) derive accurate ages and stellar masses based on robust measurements of spectral features such as the Mg(UV) or D(4000) indices; (3) measure their redshift with an accuracy Δ z/(1+z)<0.02; and (4) study emission-line galaxies (starbursts and AGN) up to very high redshifts. The well-sampled optical SEDs provided by SHARDS for all sources in the GOODS-N field are a valuable complement for current and future surveys carried out with other telescopes (e.g., Spitzer, HST, and Herschel).

  17. Development and Validation of UV Spectrophotometric Method For Estimation of Dolutegravir Sodium in Tablet Dosage Form

    International Nuclear Information System (INIS)

    Balasaheb, B.G.

    2015-01-01

    A simple, rapid, precise and accurate spectrophotometric method has been developed for quantitative analysis of Dolutegravir sodium in tablet formulations. The initial stock solution of Dolutegravir sodium was prepared in methanol solvent and subsequent dilution was done in water. The standard solution of Dolutegravir sodium in water showed maximum absorption at wavelength 259.80 nm. The drug obeyed Beer-Lamberts law in the concentration range of 5-40 μg/ mL with coefficient of correlation (R"2) was 0.9992. The method was validated as per the ICH guidelines. The developed method can be adopted in routine analysis of Dolutegravir sodium in bulk or tablet dosage form and it involves relatively low cost solvents and no complex extraction techniques. (author)

  18. THE DETECTION RATE OF EARLY UV EMISSION FROM SUPERNOVAE: A DEDICATED GALEX/PTF SURVEY AND CALIBRATED THEORETICAL ESTIMATES

    Energy Technology Data Exchange (ETDEWEB)

    Ganot, Noam; Gal-Yam, Avishay; Ofek, Eran O.; Sagiv, Ilan; Waxman, Eli; Lapid, Ofer [Department of Particle Physics and Astrophysics, Faculty of Physics, The Weizmann Institute of Science, Rehovot 76100 (Israel); Kulkarni, Shrinivas R.; Kasliwal, Mansi M. [Cahill Center for Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Ben-Ami, Sagi [Smithsonian Astrophysical Observatory, Harvard-Smithsonian Ctr. for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Chelouche, Doron; Rafter, Stephen [Physics Department, Faculty of Natural Sciences, University of Haifa, 31905 Haifa (Israel); Behar, Ehud; Laor, Ari [Physics Department, Technion Israel Institute of Technology, 32000 Haifa (Israel); Poznanski, Dovi; Nakar, Ehud; Maoz, Dan [School of Physics and Astronomy, Tel Aviv University, 69978 Tel Aviv (Israel); Trakhtenbrot, Benny [Institute for Astronomy, ETH Zurich, Wolfgang-Pauli-Strasse 27 Zurich 8093 (Switzerland); Neill, James D.; Barlow, Thomas A.; Martin, Christofer D., E-mail: noam.ganot@gmail.com [California Institute of Technology, 1200 East California Boulevard, MC 278-17, Pasadena, CA 91125 (United States); Collaboration: ULTRASAT Science Team; WTTH consortium; GALEX Science Team; Palomar Transient Factory; and others

    2016-03-20

    The radius and surface composition of an exploding massive star, as well as the explosion energy per unit mass, can be measured using early UV observations of core-collapse supernovae (SNe). We present the first results from a simultaneous GALEX/PTF search for early ultraviolet (UV) emission from SNe. Six SNe II and one Type II superluminous SN (SLSN-II) are clearly detected in the GALEX near-UV (NUV) data. We compare our detection rate with theoretical estimates based on early, shock-cooling UV light curves calculated from models that fit existing Swift and GALEX observations well, combined with volumetric SN rates. We find that our observations are in good agreement with calculated rates assuming that red supergiants (RSGs) explode with fiducial radii of 500 R{sub ⊙}, explosion energies of 10{sup 51} erg, and ejecta masses of 10 M{sub ⊙}. Exploding blue supergiants and Wolf–Rayet stars are poorly constrained. We describe how such observations can be used to derive the progenitor radius, surface composition, and explosion energy per unit mass of such SN events, and we demonstrate why UV observations are critical for such measurements. We use the fiducial RSG parameters to estimate the detection rate of SNe during the shock-cooling phase (<1 day after explosion) for several ground-based surveys (PTF, ZTF, and LSST). We show that the proposed wide-field UV explorer ULTRASAT mission is expected to find >85 SNe per year (∼0.5 SN per deg{sup 2}), independent of host galaxy extinction, down to an NUV detection limit of 21.5 mag AB. Our pilot GALEX/PTF project thus convincingly demonstrates that a dedicated, systematic SN survey at the NUV band is a compelling method to study how massive stars end their life.

  19. Spectrophotometric analysis of irradiated spices

    Energy Technology Data Exchange (ETDEWEB)

    Josimovic, L; Cudina, I

    1987-01-01

    Seven different spices (thyme, cinnamon, coriander, caraway, pimento, paprika, black pepper) were treated by gamma radiation at an absorbed dose of 10 kGy, and the effect on chemical quality was determined. The effects of this dose were assessed by spectrophotometric analysis of some water-soluble constituents of spices (carbohydrates; carbonyl compounds) and on the content of water-insoluble steam-volatile oils. The colour of paprika and the content of piperine in pepper held in different packaging materials were measured in unirradiated and irradiated samples as a function of storage time. In all cases irradiation does not bring about any distinct qualitative or quantitative chemical changes based on spectrophotometric analysis of spice extracts.

  20. Application of spectrophotometric, densitometric, and HPLC techniques as stability indicating methods for determination of Zaleplon in pharmaceutical preparations

    Science.gov (United States)

    Metwally, Fadia H.; Abdelkawy, M.; Abdelwahab, Nada S.

    2007-12-01

    Spectrophotometric, spectrodensitometric and HPLC are stability indicating methods described for determination of Zaleplon in pure and dosage forms. As Zaleplon is easily degradable, the proposed techniques in this manuscript are adopted for its determination in presence of its alkaline degradation product, namely N-[4-(3-cyano-pyrazolo[1,5a]pyridin-7-yl)-phenyl]- N-ethyl-acetamide. These approaches are successfully applied to quantify Zaleplon using the information included in the absorption spectra of appropriate solutions. The second derivative (D 2) spectrophotometric method, allows determination of Zaleplon without interference of its degradate at 235.2 nm using 0.01N HCl as a solvent with obedience to Beer's law over a concentration range of 1-10 μg ml -1 with mean percentage recovery 100.24 ± 0.86%. The first derivative of the ratio spectra ( 1DD) based on the simultaneous use of ( 1DD) and measurement at 241.8 nm using the same solvent and over the same concentration range as (D 2) spectrophotometric method, with mean percentage recovery 99.9 ± 1.07%. The spectrodensitometric analysis allows the separation and quantitation of Zaleplon from its degradate on silica gel plates using chloroform:acetone:ammonia solution (9:1:0.2 by volume) as a mobile phase. This method depends on quantitave densitometric evaluation of thin layer chromatogram of Zaleplon at 338 nm over a concentration range of 0.2-1 μg band -1, with mean percentage recovery 99.73 ± 1.35. Also a reversed-phase liquid chromatographic method using 5-C8 (22 cm × 4.6 mm i.d. 5 μm particle size) column was described and validated for quantitation of Zaleplon using acetonitrile:deionised water (35:65, v/v) as a mobile phase using Paracetamol as internal standard and a flow rate of 1.5 ml min -1 with UV detection of the effluent at 232 nm at ambient temperature over a concentration range of 2-20 μg ml -1 with mean percentage recovery 100.19 ± 1.15%. The insignificance difference of the proposed

  1. Capillary electrophoresis method with UV-detection for analysis of free amino acids concentrations in food.

    Science.gov (United States)

    Omar, Mei Musa Ali; Elbashir, Abdalla Ahmed; Schmitz, Oliver J

    2017-01-01

    Simple and inexpensive capillary electrophoresis with UV-detection method (CE-UV) was optimized and validated for determination of six amino acids namely (alanine, asparagine, glutamine, proline, serine and valine) for Sudanese food. Amino acids in the samples were derivatized with 4-chloro-7-nitro-2,1,3-benzoxadiazole (NBD-Cl) prior to CE-UV analysis. Labeling reaction conditions (100mM borate buffer at pH 8.5, labeling reaction time 60min, temperature 70°C and NBD-Cl concentration 40mM) were systematically investigated. The optimal conditions for the separation were 100mM borate buffer at pH 9.7 and detected at 475nm. The method was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), precision (repeatability) (RSD%) and accuracy (recovery). Good linearity was achieved for all amino acids (r(2)>0.9981) in the concentration range of 2.5-40mg/L. The LODs in the range of 0.32-0.56mg/L were obtained. Recoveries of amino acids ranging from 85% to 108%, (n=3) were obtained. The validated method was successfully applied for the determination of amino acids for Sudanese food samples. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Contribution to Casein Determination by UV Spectrophotometry

    Directory of Open Access Journals (Sweden)

    Stefanescu Raluca

    2017-12-01

    Full Text Available In the present paper, the interaction between copper ions and proteins is presented, in order to elaborate a simple and rapid spectrophotometric assay of casein in milk. Under alkaline conditions, copper ions form the biuret complex with the proteins, which can be used in protein determination. Although very specific, the biuret method is less sensitive. Using insoluble copper phosphate, casein is able to extract copper ions, with which it forms the biuret complex, while either the complex or copper ions could be determined in the ultraviolet range. Indeed, an increased absorbance of biuret complex at 215 nm was found. Nevertheless, copper ions can be determined in UV as well, their concentration being proportional to that of casein. When used tetraglycine instead casein, mass spectrometric measurements at pH higher than 11 revealed the formation of complexes with many copper ions bound to each peptide bond-containing molecule. Nevertheless, on diluting the biuret solution the complex may dissociate leading to very complex UV spectra that should be further studied.

  3. 340nm UV LED excitation in time-resolved fluorescence system for europium-based immunoassays detection

    OpenAIRE

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2017-01-01

    In immunoassay analyzers for in-vitro diagnostics, Xenon flash lamps have been widely used as excitation light sources. Recent advancements in UV LED technology and its advantages over the flash lamps such as smaller footprint, better wall-plug efficiency, narrow emission spectrum, and no significant afterglow, have made them attractive light sources for gated detection systems. In this paper, we report on the implementation of a 340 nm UV LED based time-resolved fluorescence system based on ...

  4. Extraction of phenolic compounds from extra virgin olive oil by a natural deep eutectic solvent: Data on UV absorption of the extracts.

    Science.gov (United States)

    Paradiso, Vito Michele; Clemente, Antonia; Summo, Carmine; Pasqualone, Antonella; Caponio, Francesco

    2016-09-01

    This data article refers to the paper "Towards green analysis of virgin olive oil phenolic compounds: extraction by a natural deep eutectic solvent and direct spectrophotometric detection" [1]. A deep eutectic solvent (DES) based on lactic acid and glucose was used as green solvent for phenolic compounds. Eight standard phenolic compounds were solubilized in the DES. Then, a set of extra virgin olive oil (EVOO) samples (n=65) were submitted to liquid-liquid extraction by the DES. The standard solutions and the extracts were analyzed by UV spectrophotometry. This article reports the spectral data of both the standard solutions and the 65 extracts, as well as the total phenolic content of the corresponding oils, assessed by the Folin-Ciocalteu assay.

  5. Quantitation of underivatized branched-chain amino acids in sport nutritional supplements by capillary electrophoresis with direct or indirect UV absorbance detection.

    Science.gov (United States)

    Qiu, Jun; Wang, Jinhao; Xu, Zhongqi; Liu, Huiqing; Ren, Jie

    2017-01-01

    The branched-chain amino acids (BCAAs) including leucine (Leu), isoleucine (Ile) and valine (Val) play a pivotal role in the human body. Herein, we developed capillary electrophoresis (CE) coupled with conventional UV detector to quantify underivatized BCAAs in two kinds of sport nutritional supplements. For direct UV detection at 195 nm, the BCAAs (Leu, two enantiomers of Ile and Val) were separated in a background electrolyte (BGE) consisting of 40.0 mmol/L sodium tetraborate, and 40.0 mmol/L β-cyclodextrin (β-CD) at pH 10.2. In addition, the indirect UV detection at 264 nm was achieved in a BGE of 2.0 mmol/L Na2HPO4, 10.0 mmol/L p-aminosalicylic acid (PAS) as UV absorbing probe, and 40.0 mmol/L β-CD at pH 12.2. The β-CD significantly benefited the isomeric separation of Leu, L- and D-Ile. The optimal conditions allowed the LODs (limit of detections) of direct and indirect UV absorption detection to be tens μmol/L level, which was comparable to the reported CE inline derivatization method. The RSDs (relative standard deviations) of migration time and peak area were less than 0.91% and 3.66% (n = 6). Finally, CE with indirect UV detection method was applied for the quantitation of BCAAs in two commercial sport nutritional supplements, and good recovery and precision were obtained. Such simple CE method without tedious derivatization process is feasible of quality control and efficacy evaluation of the supplemental proteins.

  6. Quantitation of underivatized branched-chain amino acids in sport nutritional supplements by capillary electrophoresis with direct or indirect UV absorbance detection.

    Directory of Open Access Journals (Sweden)

    Jun Qiu

    Full Text Available The branched-chain amino acids (BCAAs including leucine (Leu, isoleucine (Ile and valine (Val play a pivotal role in the human body. Herein, we developed capillary electrophoresis (CE coupled with conventional UV detector to quantify underivatized BCAAs in two kinds of sport nutritional supplements. For direct UV detection at 195 nm, the BCAAs (Leu, two enantiomers of Ile and Val were separated in a background electrolyte (BGE consisting of 40.0 mmol/L sodium tetraborate, and 40.0 mmol/L β-cyclodextrin (β-CD at pH 10.2. In addition, the indirect UV detection at 264 nm was achieved in a BGE of 2.0 mmol/L Na2HPO4, 10.0 mmol/L p-aminosalicylic acid (PAS as UV absorbing probe, and 40.0 mmol/L β-CD at pH 12.2. The β-CD significantly benefited the isomeric separation of Leu, L- and D-Ile. The optimal conditions allowed the LODs (limit of detections of direct and indirect UV absorption detection to be tens μmol/L level, which was comparable to the reported CE inline derivatization method. The RSDs (relative standard deviations of migration time and peak area were less than 0.91% and 3.66% (n = 6. Finally, CE with indirect UV detection method was applied for the quantitation of BCAAs in two commercial sport nutritional supplements, and good recovery and precision were obtained. Such simple CE method without tedious derivatization process is feasible of quality control and efficacy evaluation of the supplemental proteins.

  7. Colloidal silver nanoparticles prepared by UV-light induced citrate reduction technique for the quantitative detection of uric acid

    Science.gov (United States)

    Maity, Anupam; Panda, Sovan Kumar

    2018-04-01

    Reddish-yellow color colloid consisting of silver nanoparticles (Ag NPs) has been synthesized by reducing aqueous AgNO3 solution by photo-induced citrate reduction technique under UV light. As prepared colloid exhibits single and intense plasmonic absorption peak in the violet region of the visible spectra with the peak centered at 405 nm. The NPs are fine and spherical with diameter ranging from 5 to 10 nm. These colloidal NPs have been used for the quantitative detection of uric acid by UV-VIS spectroscopy. A linear red shifting of the characteristics Plasmonic absorption peak of Ag NPs is observed with uric acid concentration. Uric acid can be detected by UV-VIS spectroscopy down to 5 nM limit using the prepared colloid.

  8. Flow analysis methods for the direct ultra-violet spectrophotometric measurement of nitrate and total nitrogen in freshwaters

    Energy Technology Data Exchange (ETDEWEB)

    Gentle, Brady S.; Ellis, Peter S.; Grace, Michael R. [Water Studies Centre, School of Chemistry, Monash University, Victoria 3800 (Australia); McKelvie, Ian D., E-mail: iandm@unimelb.edu.au [School of Chemistry, University of Melbourne, Victoria 3010 (Australia); School of Geography, Earth and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL4 8AA (United Kingdom)

    2011-10-17

    Highlights: {yields} Second derivative UV spectrophotometry has been used to determine nitrate and total N using flow analysis techniques. {yields} A simple flow system with a single-reflection flow-through cell was used for the UV measurement of nitrate. {yields} Total N was determined after on-line UV photooxidation with alkaline peroxodisulfate. {yields} Analyses carried out using the developed flow systems show a high degree of agreement with comparative analyses. {yields} This method requires no colorimetric reagents and eliminates the requirement for a toxic cadmium reduction column. - Abstract: Second derivative ultra-violet spectrophotometric methods are described for the measurement of nitrate and total nitrogen in freshwaters using flow analysis techniques. A simple flow system consisting of a peristaltic pump and a single-reflection flow-through cell was used for the measurement of nitrate. Quantification of total nitrogen using alkaline peroxodisulfate photo-digestion was achieved by incorporating an ultra-violet photo-reactor, a hollow-fibre filter and a debubbler into the flow system. The nitrate system featured a limit of detection of 0.04 mg N L{sup -1}, 0.4%RSD (1 mg N L{sup -1} as nitrate, n = 10), a coefficient of determination (R{sup 2}) of 0.9995 over the calibration range 0.0-2.0 mg N L{sup -1}, and a data acquisition time of 1.5 s per spectrum. The total nitrogen system featured a limit of detection of 0.05 mg N L{sup -1}, 1%RSD (1 mg N L{sup -1} as ammonium chloride, n = 10), a coefficient of determination of 0.9989 over the calibration range 0.0-2.0 mg N L{sup -1}, and a throughput of 5 sample h{sup -1} measured in triplicate. Digestions of five model nitrogen compounds returned recoveries of >88%. Determinations carried out using the developed systems show a high degree of agreement with data obtained using reference methods. These methods require no colorimetric reagents and eliminate the requirement for a toxic cadmium reduction column

  9. Flow analysis methods for the direct ultra-violet spectrophotometric measurement of nitrate and total nitrogen in freshwaters

    International Nuclear Information System (INIS)

    Gentle, Brady S.; Ellis, Peter S.; Grace, Michael R.; McKelvie, Ian D.

    2011-01-01

    Highlights: → Second derivative UV spectrophotometry has been used to determine nitrate and total N using flow analysis techniques. → A simple flow system with a single-reflection flow-through cell was used for the UV measurement of nitrate. → Total N was determined after on-line UV photooxidation with alkaline peroxodisulfate. → Analyses carried out using the developed flow systems show a high degree of agreement with comparative analyses. → This method requires no colorimetric reagents and eliminates the requirement for a toxic cadmium reduction column. - Abstract: Second derivative ultra-violet spectrophotometric methods are described for the measurement of nitrate and total nitrogen in freshwaters using flow analysis techniques. A simple flow system consisting of a peristaltic pump and a single-reflection flow-through cell was used for the measurement of nitrate. Quantification of total nitrogen using alkaline peroxodisulfate photo-digestion was achieved by incorporating an ultra-violet photo-reactor, a hollow-fibre filter and a debubbler into the flow system. The nitrate system featured a limit of detection of 0.04 mg N L -1 , 0.4%RSD (1 mg N L -1 as nitrate, n = 10), a coefficient of determination (R 2 ) of 0.9995 over the calibration range 0.0-2.0 mg N L -1 , and a data acquisition time of 1.5 s per spectrum. The total nitrogen system featured a limit of detection of 0.05 mg N L -1 , 1%RSD (1 mg N L -1 as ammonium chloride, n = 10), a coefficient of determination of 0.9989 over the calibration range 0.0-2.0 mg N L -1 , and a throughput of 5 sample h -1 measured in triplicate. Digestions of five model nitrogen compounds returned recoveries of >88%. Determinations carried out using the developed systems show a high degree of agreement with data obtained using reference methods. These methods require no colorimetric reagents and eliminate the requirement for a toxic cadmium reduction column. The overlap of chloride and nitrate spectra in seawater is

  10. Spectrophotometric Determination of Zinc Using 7-(4-Nitrophenylazo-8-Hydroxyquinoline-5-Sulfonic Acid

    Directory of Open Access Journals (Sweden)

    Korn Maria das Graças Andrade

    1999-01-01

    Full Text Available A sensitive and selective spectrophotometric method is proposed for the rapid determination of zinc(II using an 8-hydroxyquinoline derivative, 7-(4-nitrophenylazo-8-hydroxyquinoline-5-sulfonic acid (p-NIAZOXS, as a new spectrophotometric reagent. The reaction between the p-NIAZOXS and zinc(II is instantaneous at pH 9.2 (borax buffer and the absorbance remains stable for over 24 h. The method allows the determination of zinc over the range of 0.05-1.0 mug mL-1 with a molar absorptivity of 3.75x10(4 L mol-1 cm-1 and features a detection limit of 15 ng mL-1. The proposed method has been successfully applied to the determination of zinc in several pharmaceutical preparations and copper alloys. The precision (R.S.D. < 2% and the accuracy obtained were satisfactory.

  11. Two-photon excited UV fluorescence for protein crystal detection

    International Nuclear Information System (INIS)

    Madden, Jeremy T.; DeWalt, Emma L.; Simpson, Garth J.

    2011-01-01

    Complementary measurements using SONICC and TPE-UVF allow the sensitive and selective detection of protein crystals. Two-photon excited ultraviolet fluorescence (TPE-UVF) microscopy is explored for sensitive protein-crystal detection as a complement to second-order nonlinear optical imaging of chiral crystals (SONICC). Like conventional ultraviolet fluorescence (UVF), TPE-UVF generates image contrast based on the intrinsic fluorescence of aromatic residues, generally producing higher fluorescence emission within crystals than the mother liquor by nature of the higher local protein concentration. However, TPE-UVF has several advantages over conventional UVF, including (i) insensitivity to optical scattering, allowing imaging in turbid matrices, (ii) direct compatibility with conventional optical plates and windows by using visible light for excitation, (iii) elimination of potentially damaging out-of-plane UV excitation, (iv) improved signal to noise through background reduction from out-of-plane excitation and (v) relatively simple integration into instrumentation developed for SONICC

  12. Quantification of protein concentration using UV absorbance and Coomassie dyes.

    Science.gov (United States)

    Noble, James E

    2014-01-01

    The measurement of a solubilized protein concentration in solution is an important assay in biochemistry research and development labs for applications ranging from enzymatic studies to providing data for biopharmaceutical lot release. Spectrophotometric protein quantification assays are methods that use UV and visible spectroscopy to rapidly determine the concentration of protein, relative to a standard, or using an assigned extinction coefficient. Where multiple samples need measurement, and/or the sample volume and concentration is limited, preparations of the Coomassie dye commonly known as the Bradford assay can be used. © 2014 Elsevier Inc. All rights reserved.

  13. UV Spectrophotometric Method for theEstimation of Itopride Hydrochloride in Pharmaceutical Formulation

    OpenAIRE

    K. R. Gupta; R. R. Joshi; R. B. Chawla; S. G. Wadodkar

    2010-01-01

    Three simple, precise and economical UV methods have been developed for the estimation of itopride hydrochloride in pharmaceutical formulations. Itopride hydrochloride in distilled water shows the maximum absorbance at 258.0 nm (Method A) and in first order derivative spectra of the same shows sharp peak at 247.0 nm, when n = 1 (Method B). Method C utilises area under curve (AUC) in the wavelength range from 262.0-254.0 nm for analysis of itopride hydrochloride. The drug was found to obey Bee...

  14. Detection of Organic Matter in Greenland Ice Cores by Deep-UV Fluorescence

    Science.gov (United States)

    Willis, M.; Malaska, M.; Wanger, G.; Bhartia, R.; Eshelman, E.; Abbey, W.; Priscu, J. C.

    2017-12-01

    The Greenland Ice Sheet is an Earthly analog for icy ocean worlds in the outer Solar System. Future missions to such worlds including Europa, Enceladus, and Titan may potentially include spectroscopic instrumentation to examine the surface/subsurface. The primary goal of our research is to test deep UV/Raman systems for in the situ detection and localization of organics in ice. As part of this effort we used a deep-UV fluorescence instrument able to detect naturally fluorescent biological materials such as aromatic molecules found in proteins and whole cells. We correlated these data with more traditional downstream analyses of organic material in natural ices. Supraglacial ice cores (2-4 m) were collected from several sites on the southwest outlet of the Greenland Ice Sheet using a 14-cm fluid-free mechanical coring system. Repeat spectral mapping data were initially collected longitudinally on uncut core sections. Cores were then cut into 2 cm thick sections along the longitudinal axis, slowly melted and analyzed for total organic carbon (TOC), total dissolved nitrogen (TDN), and bacterial density. These data reveal a spatial correlation between organic matter concentration, cell density, and the deep UV fluorescence maps. Our results provide a profile of the organics embedded within the ice from the top surface into the glacial subsurface, and the TOC:TDN data from the clean interior of the cores are indicative of a biological origin. This work provides a background dataset for future work to characterize organic carbon in the Greenland Ice Sheet and validation of novel instrumentation for in situ data collection on icy bodies.

  15. Spectrophotometric Investigations of Macrolide Antibiotics: A Brief Review

    Directory of Open Access Journals (Sweden)

    Mrudul R. Keskar

    2015-01-01

    Full Text Available Macrolides, one of the most commonly used class of antibiotics, are a group of drugs produced by Streptomyces species. They belong to the polyketide class of natural products. Their activity is due to the presence of a large macrolide lactone ring with deoxy sugar moieties. They are protein synthesis inhibitors and broad-spectrum antibiotics, active against both gram-positive and gram-negative bacteria. Different analytical techniques have been reported for the determination of macrolides such as chromatographic methods, flow injection methods, spectrofluorometric methods, spectrophotometric methods, and capillary electrophoresis methods. Among these methods, spectrophotometric methods are sensitive and cost effective for the analysis of various antibiotics in pharmaceutical formulations as well as biological samples. This article reviews different spectrophotometric methods for the determination of macrolide antibiotics.

  16. Effect of fungal mycelia on the HPLC-UV and UV-vis spectrophotometric assessment of mycelium-bound epoxide hydrolase using glycidyl phenyl ether.

    Science.gov (United States)

    Dolcet, Marta M; Torres, Mercè; Canela, Ramon

    2016-06-25

    The use of mycelia as biocatalysts has technical and economic advantages. However, there are several difficulties in obtaining accurate results in mycelium-catalysed reactions. Firstly, sample extraction, indispensable because of the presence of mycelia, can bring into the extract components with a similar structure to that of the analyte of interest; secondly, mycelia can influence the recovery of the analyte. We prepared calibration standards of 3-phenoxy-1,2-propanediol (PPD) in the pure solvent and in the presence of mycelia (spiked before or after extraction) from five fungi (Aspergillus niger, Aspergillus tubingensis, Penicillium aurantiogriseum, Penicillium sp. and Aspergillus terreus). The quantification of PPD was carried out by HPLC-UV and UV-vis spectrophotometry. The manuscript shows that the last method is as accurate as the HPLC method. However, the colorimetric method led to a higher data throughput, which allowed the study of more samples in a shorter time. Matrix effects were evaluated visually from the plotted calibration data and statistically by simultaneously comparing the intercept and slope of calibration curves performed with solvent, post-extraction spiked standards and pre-extraction spiked standards. Significant differences were found between the post- and pre-extraction spiked matrix-matched functions. Pre-extraction spiked matrix-matched functions based on A. tubingensis mycelia, selected as the reference, were validated and used to compensate for low recoveries. These validated functions were successfully applied to the quantification of PPD achieved during the hydrolysis of glycidyl phenyl ether by mycelium-bound epoxide hydrolases and equivalent hydrolysis yields were determined by HPLC-UV and UV-vis spectrophotometry. This study may serve as starting point to implement matrix effects evaluation when mycelium-bound epoxide hydrolases are studied. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Conformation of L-Tyrosine Studied by Fluorescence-Detected UV-UV and IR-UV Double-Resonance Spectroscopy

    OpenAIRE

    Inokuchi, Yoshiya; Kobayashi, Yusuke; Ito, Takafumi; Ebata, Takayuki

    2007-01-01

    The laser-induced fluorescence spectrum of jet-cooled L-tyrosine exhibits more than 20 vibronic bands in the 35450-35750 cm-1 region. We attribute these bands to eight conformers by using results of UV-UV hole-burning spectroscopy. These isomers are classified into four groups; each group consists of two rotational isomers that have a similar side-chain conformation but different orientations of the phenolic OH. The splitting of band origins of rotational isomers is 31, 21, 5, and 0 cm-1 for ...

  18. Spectrophotometric determination of procainamide hydrochloride using sodium periodate

    Directory of Open Access Journals (Sweden)

    S. Al-Tamrah

    2015-09-01

    Full Text Available A simple spectrophotometric method has been described for the determination of procainamide hydrochloride. The method is based on the oxidation of procainamide hydrochloride by sodium periodate in the presence of sulfuric acid and measurement of the absorbance of the violet color formed at 531 nm. Parameters affecting the reaction were studied and conditions were optimized. Linear calibration graph was obtained from 50 to 700 μg ml−1 of procainamide hydrochloride and the limit of detection was 25 μg ml−1. The method was successfully applied for the determination of procainamide hydrochloride in pharmaceutical preparation.

  19. Protective effects of polyamines against UV-A and UV-B illumination in Physcia semipinnata thalli

    Directory of Open Access Journals (Sweden)

    Esmer Işıl

    2017-04-01

    Full Text Available The damage to DNA induced by UV-A and UV-B and protective effects of the polyamines putrescine (put, spermidine (spd and spermine (spm were investigated on the lichen Physcia semipinnata in the present study. Our results suggest that significant alterations of the photosynthetic quantum yield ratio occurred in response to increased UV-A and UV-B exposure time. The photosynthetic quantum yield ratio gradually decreased in P. semipinnata following exposure to UV-A and UV-B. Physcia semipinnata thalli which were treated with a polyamine in a concentration of 1 mM were not affected by UV-A exposure for 72 h. In the case of UV-B treatment, the protective polyamine dosage was 0.25 mM. We also used the random amplified polymorphic DNA (RAPD technique to detect DNA damage. The main changes observed in the RAPD profiles, which were obtained using 12 RAPD primers, were the appearance or disappearance of different bands and variation of their intensities. The use of at least three different primers allowed detection of specific band patterns in both UV-A- and UV-B-exposed samples treated with polyamines as compared to untreated ones.

  20. Males do not see only red: UV wavelengths and male territorial aggression in the three-spined stickleback ( Gasterosteus aculeatus)

    Science.gov (United States)

    Rick, Ingolf P.; Bakker, Theo C. M.

    2008-07-01

    Animal colour signals serve important functions in intraspecific interactions, including species recognition, mate choice and agonistic behaviour. An increasing interest concerns ultraviolet (UV) wavelengths, for instance studies on the effect of UV in mating decisions. More recently, some studies also established that UV signals affect intrasexual interactions. We studied the role of UV during aggressive encounters between male three-spined sticklebacks ( Gasterosteus aculeatus), a species in which UV has an effect on female and male mate choice and shoaling behaviour. To that aim, we compared the aggressive response of a territorial male to male intruders, either seen in UV-including (UV+) or UV-lacking (UV-) conditions. Our prediction was that, if UV wavelengths are used in male-male competition, a territorial male should show less competitive behaviour towards an intruder representing a lower threat, i.e. the one presented without UV light. Male sticklebacks showed significantly lower levels of aggression towards male opponents lacking an UV component to their coloration than male opponents possessing this colour component. Discrimination was not influenced by a difference in brightness between the UV+ and UV- stimuli. Finally, we present some reflectance-spectrophotometrical data of two skin regions (cheek and abdomen) of the experimental males and analysed relationships between colorimetric variables, body variables and behaviour. Our study emphasises that UV visual cues are of importance in different communicational tasks in the three-spined stickleback.

  1. New Spectrophotometric and Conductometric Methods for Macrolide Antibiotics Determination in Pure and Pharmaceutical Dosage Forms Using Rose Bengal

    Directory of Open Access Journals (Sweden)

    Rania A. Sayed

    2013-01-01

    Full Text Available Two Simple, accurate, precise, and rapid spectrophotometric and conductometric methods were developed for the estimation of erythromycin thiocyanate (I, clarithromycin (II, and azithromycin dihydrate (III in both pure and pharmaceutical dosage forms. The spectrophotometric procedure depends on the reaction of rose bengal and copper with the cited drugs to form stable ternary complexes which are extractable with methylene chloride, and the absorbances were measured at 558, 557, and 560 nm for (I, (II, and (III, respectively. The conductometric method depends on the formation of an ion-pair complex between the studied drug and rose bengal. For the spectrophotometric method, Beer's law was obeyed. The correlation coefficient ( for the studied drugs was found to be 0.9999. The molar absorptivity (, Sandell’s sensitivity, limit of detection (LOD, and limit of quantification (LOQ were also calculated. The proposed methods were successfully applied for the determination of certain pharmaceutical dosage forms containing the studied drugs

  2. Textile UV detector with 2,3,5-triphenyltetrazolium chloride as an active compound

    International Nuclear Information System (INIS)

    Kozicki, Marek; Sasiadek, Elzbieta

    2011-01-01

    In this paper, results on the construction of a new flat textile-based UV light dosimeter are reported. As a textile support polyamide woven fabric was chosen, which was surface-modified with 2,3,5-triphenyltetrazolium chloride (TTC). At first, spectrophotometric and dynamic laser light scattering results on the steady-state UV irradiation of aqueous TTC solutions in the presence of oxygen are discussed. If irradiated, TTC converts to the corresponding formazan molecules of red colour. The size and size distribution of the particles is related to the absorbed radiation and pH of the solution. When TTC molecules reside on polyamide textile, UV irradiation causes a colour change from white to deep red. The tinge intensity depends on the absorbed energy per unit surface area. On this basis, the calibration parameters of the detectors, such as dose sensitivity, dose range, quasi-linear dose range, were calculated. Furthermore, the improvement of the dosimeters' resistance to atmospheric conditions was achieved and assessed through washing fastness tests. Finally, the detectors were proved to be adequate for measurements of the 2D distribution of absorbed UV energy. A simple method of UV dose distribution measurements was proposed. The textile-based systems show promise as dosimeters.

  3. Incipient fault diagnosis of power transformers using optical spectro-photometric technique

    Science.gov (United States)

    Hussain, K.; Karmakar, Subrata

    2015-06-01

    Power transformers are the vital equipment in the network of power generation, transmission and distribution. Mineral oil in oil-filled transformers plays very important role as far as electrical insulation for the winding and cooling of the transformer is concerned. As transformers are always under the influence of electrical and thermal stresses, incipient faults like partial discharge, sparking and arcing take place. As a result, mineral oil deteriorates there by premature failure of the transformer occurs causing huge losses in terms of revenue and assets. Therefore, the transformer health condition has to be monitored continuously. The Dissolved Gas Analysis (DGA) is being extensively used for this purpose, but it has some drawbacks like it needs carrier gas, regular instrument calibration, etc. To overcome these drawbacks, Ultraviolet (UV) -Visible and Fourier Transform Infrared (FTIR) Spectro-photometric techniques are used as diagnostic tools for investigating the degraded transformer oil affected by electrical, mechanical and thermal stresses. The technique has several advantages over the conventional DGA technique.

  4. Differential spectrophotometric determination of plutonium

    International Nuclear Information System (INIS)

    Lecat, J.

    1980-01-01

    Differential spectrophotometric method is used for determination of plutonium reduced to oxydation state III+ by ascorbic acid, at 560 nm. Concentration of solutions is 4 g/l and accuracy of the method is better than 0,3% [fr

  5. UV light induced photodegradation of organic dye by ZnO nanocatalysts

    International Nuclear Information System (INIS)

    Sumesh, C. K.; Patel, Bhavin; Parekh, Kinnari

    2013-01-01

    Ultraviolet light induced photocatalytic activity of ZnO nanocatalyst prepared using a wet chemical precipitation route and mineralization of the methyl orange (MO) dye has been carried out in a photocatalytic reactor. The degradation of the MO was monitored spectrophotometrically and showed a decolorization efficiency of 92% after nine hours of irradiation in the MO-ZnO/UV light system. The blue shifting of maximum peak position of the MO and the formation of extra peak at 247 nm during irradiation time advances revealed that MO degrades in the form of intermediates during the photocatalytic process.

  6. Adverse Effects of UV-B Radiation on Plants Growing at Schirmacher Oasis, East Antarctica.

    Science.gov (United States)

    Singh, Jaswant; Singh, Rudra P

    2014-01-01

    This study aimed to assess the impacts of ultraviolet-B (UV-B) radiation over a 28-day period on the levels of pigments of Umbilicaria aprina and Bryum argenteum growing in field. The depletion of stratospheric ozone is most prominent over Antarctica, which receives more UV-B radiation than most other parts of the planet. Although UV-B radiation adversely affects all flora, Antarctic plants are better equipped to survive the damaging effects of UV-B owing to defenses provided by UV-B absorbing compounds and other screening pigments. The UV-B radiations and daily average ozone values were measured by sun photometer and the photosynthetic pigments were analyzed by the standard spectrophotometric methods of exposed and unexposed selected plants. The daily average atmospheric ozone values were recorded from 5 January to 2 February 2008. The maximum daily average for ozone (310.7 Dobson Units (DU)) was recorded on 10 January 2008. On that day, average UV-B spectral irradiances were 0.016, 0.071, and 0.186 W m(-2) at wavelengths of 305, 312, and 320 nm, respectively. The minimum daily average ozone value (278.6 DU) was recorded on 31 January 2008. On that day, average UV-B spectral irradiances were 0.018, 0.085, and 0.210 W m(-2) at wavelengths of 305, 312, and 320 nm, respectively. Our results concludes that following prolonged UV-B exposure, total chlorophyll levels decreased gradually in both species, whereas levels of UV-B absorbing compounds, phenolics, and carotenoids gradually increased.

  7. DETERMINATION OF PROTOPINE IN FUMARIA DENSIFLORA DC. BY TLC- DENSITOMETRIC AND SPECTROPHOTOMETRIC METHOD

    OpenAIRE

    FAFAL, Tuğçe; ÖNÜR, Mustafa Ali

    2007-01-01

    The isoquinoline alkaloid protopine in Fumaria densiflora DC. (Fumariaceae) was quantitatively determined by TLC-densitometry and spectrophotometry. In TLC-densitometry two different solvent systems as toluene : chloroform : methanol : % 25 ammonium hydroxide (5:3:1:1) and cyclohexane : diethylamine (9:1) were used and protopine was detected as 0.351 and 0.352 % respectively. The content of protopine in Fumaria densiflora DC. was estimated as 0.366 % in spectrophotometric method. The quantita...

  8. From thermometric to spectrophotometric kinetic-catalytic methods of analysis. A review.

    Science.gov (United States)

    Cerdà, Víctor; González, Alba; Danchana, Kaewta

    2017-05-15

    Kinetic-catalytic analytical methods have proved to be very easy and highly sensitive strategies for chemical analysis, that rely on simple instrumentation [1,2]. Molecular absorption spectrophotometry is commonly used as the detection technique. However, other detection systems, like electrochemical or thermometric ones, offer some interesting possibilities since they are not affected by the color or turbidity of the samples. In this review some initial experience with thermometric kinetic-catalytic methods is described, up to our current experience exploiting spectrophotometric flow techniques to automate this kind of reactions, including the use of integrated chips. Procedures for determination of inorganic and organic species in organic and inorganic matrices are presented. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. UV Radiation and Visible Light Induce hsp70 Gene Expression in the Antarctic Psychrophilic Ciliate Euplotes focardii.

    Science.gov (United States)

    Fulgentini, Lorenzo; Passini, Valerio; Colombetti, Giuliano; Miceli, Cristina; La Terza, Antonietta; Marangoni, Roberto

    2015-08-01

    The psychrophilic ciliate Euplotes focardii inhabits the shallow marine coastal sediments of Antarctica, where, over millions of years of evolution, it has reached a strict molecular adaptation to such a constant-temperature environment (about -2 °C). This long evolution at sub-zero temperatures has made E. focardii unable to respond to heat stress with the activation of its heat shock protein (hsp) 70 genes. These genes can, however, be expressed in response to other stresses, like the oxidative one, thus indicating that the molecular adaptation has exclusively altered the heat stress signaling pathways, while it has preserved hsp70 gene activation in response to other environmental stressors. Since radiative stress has proved to be affine to oxidative stress in several organisms, we investigated the capability of UV radiation to induce hsp70 transcription. E. focardii cell cultures were exposed to several different irradiation regimes, ranging from visible only to a mixture of visible, UV-A and UV-B. The irradiation values of each spectral band have been set to be comparable with those recorded in a typical Antarctic spring. Using Northern blot analysis, we measured the expression level of hsp70 immediately after irradiation (0-h-labeled samples), 1 h, and 2 h from the end of the irradiation. Surprisingly, our results showed that besides UV radiation, the visible light was also able to induce hsp70 expression in E. focardii. Moreover, spectrophotometric measurements have revealed no detectable endogenous pigments in E. focardii, making it difficult to propose a possible explanation for the visible light induction of its hsp70 genes. Further research is needed to conclusively clarify this point.

  10. Spectrophotometric observations of very low ionization HII regions in the LMC

    International Nuclear Information System (INIS)

    Pena, M.; Ruiz, M.T.; Rubio, M.

    1987-01-01

    Optical spectrophotometric observations of 17 very low ionization HII regions of the LMC are reported. Physical conditions and chemical composition of these objects are derived from the emission line intensities. The average chemical abundances obtained are: log O/H=8.49+-0.08, log N/H=6.91+-0.07 and log S/H=6.89+-0.10. We do not find evidence of any composition gradient in the LMC. The HII regions in the vicinity of the detected molecular cloud complexes show higher nebular reddening. (Author)

  11. CIEF separation, UV detection, and quantification of ampholytic antibiotics and bacteria from different matrices

    Czech Academy of Sciences Publication Activity Database

    Horká, Marie; Vykydalová, Marie; Růžička, F.; Šalplachta, Jiří; Holá, V.; Dvořáčková, M.; Kubesová, Anna; Šlais, Karel

    2014-01-01

    Roč. 406, č. 25 (2014), s. 6285-6296 ISSN 1618-2642 R&D Projects: GA MV VG20112015021 Institutional support: RVO:68081715 Keywords : capillary isoelectric focusing with UV detection * ampholytic antibiotics * Staphylococcus epidermidis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.436, year: 2014 http://hdl.handle.net/11104/0236550

  12. CIEF separation, UV detection, and quantification of ampholytic antibiotics and bacteria from different matrices

    Czech Academy of Sciences Publication Activity Database

    Horká, Marie; Vykydalová, Marie; Růžička, F.; Šalplachta, Jiří; Holá, V.; Dvořáčková, M.; Kubesová, Anna; Šlais, Karel

    Roč. 406 , č. 25 (2014), s. 6285-6296 ISSN 1618-2642 R&D Projects: GA MV VG20112015021 Institutional support: RVO:68081715 Keywords : capillary isoelectric focusing with UV detection * ampholytic antibiotics * Staphylococcus epidermidis Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.436, year: 2014 http://hdl.handle.net/11104/0236550

  13. Spectrophotometric determination of association constant

    DEFF Research Database (Denmark)

    2016-01-01

    Least-squares 'Systematic Trial-and-Error Procedure' (STEP) for spectrophotometric evaluation of association constant (equilibrium constant) K and molar absorption coefficient E for a 1:1 molecular complex, A + B = C, with error analysis according to Conrow et al. (1964). An analysis of the Charge...

  14. Validation of a spectrophotometric method to determine ciprofibrate content in tablets

    Directory of Open Access Journals (Sweden)

    Guilherme Nobre Lima do Nascimento

    2011-03-01

    Full Text Available Ciprofibrate is a drug indicated in cases of hypertriglyceridemia and mixed hyperlipidemia, but no monographs are available in official compendia for the analysis of this substance in tablets. The objective of this work was to develop and validate a spectrophotometric method for routine analysis of ciprofibrate in tablets. In this study, commercial and standard ciprofibrate were used, as well as placebo in absolute ethanol, analyzed by UV spectrophotometer. All tests followed the rules of Resolution RE-899, 2003. The results showed that the developed and validated method offers low cost, easy implementation, precision and accuracy, and may be included in the routine of quality control laboratories.O ciprofibrato é um fármaco indicado em casos de hipertrigliceridemia e hiperlipidemia mista, mas não há monografias em compêndios oficiais para a análise desta substância em comprimidos. O objetivo deste trabalho é desenvolver e validar um método espectrofotométrico para análise de rotina de ciprofibrato em comprimidos. Neste estudo foram empregados ciprofibrato comercial, padrão e placebo em etanol absoluto, analisadas por espectrofotometria UV. Todos os testes seguiram as regras da Resolução RE- 899, 2003. Os resultados mostraram que o método desenvolvido e validado apresenta baixo custo, fácil implementação, precisão e exatidão e pode ser incluído em rotina de laboratórios de controle de qualidade.

  15. Assessment of repeatability of composition of perfumed waters by high-performance liquid chromatography combined with numerical data analysis based on cluster analysis (HPLC UV/VIS - CA).

    Science.gov (United States)

    Ruzik, L; Obarski, N; Papierz, A; Mojski, M

    2015-06-01

    High-performance liquid chromatography (HPLC) with UV/VIS spectrophotometric detection combined with the chemometric method of cluster analysis (CA) was used for the assessment of repeatability of composition of nine types of perfumed waters. In addition, the chromatographic method of separating components of the perfume waters under analysis was subjected to an optimization procedure. The chromatograms thus obtained were used as sources of data for the chemometric method of cluster analysis (CA). The result was a classification of a set comprising 39 perfumed water samples with a similar composition at a specified level of probability (level of agglomeration). A comparison of the classification with the manufacturer's declarations reveals a good degree of consistency and demonstrates similarity between samples in different classes. A combination of the chromatographic method with cluster analysis (HPLC UV/VIS - CA) makes it possible to quickly assess the repeatability of composition of perfumed waters at selected levels of probability. © 2014 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  16. A simple method for determination of carmine in food samples based on cloud point extraction and spectrophotometric detection.

    Science.gov (United States)

    Heydari, Rouhollah; Hosseini, Mohammad; Zarabi, Sanaz

    2015-01-01

    In this paper, a simple and cost effective method was developed for extraction and pre-concentration of carmine in food samples by using cloud point extraction (CPE) prior to its spectrophotometric determination. Carmine was extracted from aqueous solution using Triton X-100 as extracting solvent. The effects of main parameters such as solution pH, surfactant and salt concentrations, incubation time and temperature were investigated and optimized. Calibration graph was linear in the range of 0.04-5.0 μg mL(-1) of carmine in the initial solution with regression coefficient of 0.9995. The limit of detection (LOD) and limit of quantification were 0.012 and 0.04 μg mL(-1), respectively. Relative standard deviation (RSD) at low concentration level (0.05 μg mL(-1)) of carmine was 4.8% (n=7). Recovery values in different concentration levels were in the range of 93.7-105.8%. The obtained results demonstrate the proposed method can be applied satisfactory to determine the carmine in food samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Sensitive spectrophotometric determination of ascorbic acid in drugs and foods using surface plasmon resonance band of silver nanoparticles

    Directory of Open Access Journals (Sweden)

    Kobra Zarei

    2015-12-01

    Full Text Available A simple and sensitive procedure was proposed for spectrophotometric determination of ascorbic acid. It was found that the reduction of Ag+ to silver nanoparticles (Ag-NPs by ascorbic acid in the presence of polyvinylpyrrolidone (PVP as a stabilizing agent produce very intense surface plasmon resonance peak of Ag-NPs. The plasmon absorbance of the Ag-NPs at λ = 440 nm allows the quantitative spectrophotometric detection of the ascorbic acid. The calibration curve was linear with concentration of ascorbic acid in the range of 0.5–60 μM. The detection limit was obtained as 0.08 μM. The influence of potential interfering substances on the determination of ascorbic acid was studied. The proposed method was successfully applied for the determination of ascorbic acid in some powdered drink mixtures, commercial orange juice, natural orange juice, vitamin C injection, effervescent tablet, and multivitamin tablet.

  18. TOWARD A NETWORK OF FAINT DA WHITE DWARFS AS HIGH-PRECISION SPECTROPHOTOMETRIC STANDARDS

    Energy Technology Data Exchange (ETDEWEB)

    Narayan, G.; Matheson, T.; Saha, A.; Claver, J. [National Optical Astronomy Observatory, 950 North Cherry Avenue, Tucson, AZ 85719 (United States); Axelrod, T.; Olszewski, E. [University of Arizona, Steward Observatory, 933 North Cherry Avenue, Tucson, AZ 85721 (United States); Holberg, J. B. [University of Arizona, Lunar and Planetary Laboratory, 1629 East University Boulevard, Tucson, AZ 85721 (United States); Stubbs, C. W. [Department of Physics, Harvard University, 17 Oxford Street, Cambridge, MA 02138 (United States); Bohlin, R. C.; Deustua, S.; Rest, A., E-mail: gnarayan@noao.edu [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States)

    2016-05-10

    We present the initial results from a program aimed at establishing a network of hot DA white dwarfs to serve as spectrophotometric standards for present and future wide-field surveys. These stars span the equatorial zone and are faint enough to be conveniently observed throughout the year with large-aperture telescopes. The spectra of these white dwarfs are analyzed in order to generate a non-local-thermodynamic-equilibrium model atmosphere normalized to Hubble Space Telescope colors, including adjustments for wavelength-dependent interstellar extinction. Once established, this standard star network will serve ground-based observatories in both hemispheres as well as space-based instrumentation from the UV to the near IR. We demonstrate the effectiveness of this concept and show how two different approaches to the problem using somewhat different assumptions produce equivalent results. We discuss the lessons learned and the resulting corrective actions applied to our program.

  19. A comparison of the determination and speciation of inorganic arsenic using general HPLC methodology with UV, MS and MS/MS detection.

    Science.gov (United States)

    Gilmartin, Gregory; Gingrich, Diane

    2018-04-15

    The determination and speciation of arsenic in natural resources such as drinking water and agricultural soils has been a growing concern in recent years due to its many toxicological effects [1-3]. To speciate and quantitate concentrations of arsenic, typically an ion chromatograph (IC) interfaced to an inductively coupled plasma mass spectrometer (ICP-MS) is employed [4-9]. This methodology may be very robust and sensitive, but it is expensive and not as ubiquitous as high performance liquid chromatography (HPLC) with ultraviolet (UV) absorbance detection or electrospray ionization mass spectrometry (ESI-MS). Anion exchange chromatography is a well-documented means of speciating arsenite (As(III), As 2 O 3 ) and arsenate (As(V), AsO 4 ) using UV [10], conductivity [11], or ESI-MS detection [12,13]. This paper demonstrates the utilization of common liquid chromatographic instrumentation to speciate and determines inorganic Arsenic compounds using UV or MS via selected ion recording (SIR) or multiple reaction monitoring (MRM) detection. This paper describes the analysis of arsenite and arsenate samples prepared using both deionized and ground water. The limit of quantitation for the techniques described in this paper for samples spiked in ground water were 454 ppb (As(III)) and 562 ppb (As(V)) for UV detection, 45.4 ppb (As(III)) and 56.2 ppb (As(V)) for SIR detection, and 4.54 ppb (As(III)) and 5.62 ppb (As(V)) for MRM detection. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Antioxidant enzymes expression in Pseudomonas aeruginosa exposed to UV-C radiation.

    Science.gov (United States)

    Salma, Kloula Ben Ghorbal; Lobna, Maalej; Sana, Khefacha; Kalthoum, Chourabi; Imene, Ouzari; Abdelwaheb, Chatti

    2016-07-01

    It was well known that, UV-C irradiation increase considerably the reactive oxygen species (ROS) levels in eukaryotic and prokaryotic organisms. In the enzymatic ROS-scavenging pathways, superoxide dismutase (SOD), Catalase (CAT), and peroxidase (POX) were developed to deal with oxidative stress. In this study, we investigated the effects of UV-C radiations on antioxidant enzymes (catalase, superoxide dismutase, and peroxidases) expression in Pseudomonas aeruginosa. Catalase, superoxide dismutase, and peroxidases activities were determined spectrophotometrically. Isozymes of superoxide dismutase were revealed by native gel activity staining method. Lipid peroxidation was determined by measuring malondialdehyde formation. Our results showed that superoxide dismutase, catalase and peroxidase activities exhibited a gradual increase during the exposure time (30 min). However, the superoxide dismutase activity was maximized at 15 min. Native gel activity staining assays showed the presence of three superoxide dismutase isozymes. The iron-cofactored isoform activity was altered after exposure to UV-C stress. These finding suggest that catalase and peroxidase enzymes have the same importance toward UV-C rays at shorter and longer exposure times and this may confer additional protection to superoxide dismutase from damage caused by lipid peroxidation. Moreover, our data demonstrate the significant role of the antioxidant system in the resistance of this important human pathogen. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Separation and spectrophotometric determination of elements

    International Nuclear Information System (INIS)

    Marczenko, Z.

    1986-01-01

    This book is a useful text intended as a reference for the laboratory that is either involved in spectrophotometric analysis or requires separations prior to analysis by any method. It attempts to cover a diverse series of topics in fewer than 700 pages. Part I of the book covers general topics such as separation schemes (solvent extraction, precipitation, volatility, ion exchange), principles and instrumentation used for spectrophotometry, and color reagents in only 119 pages. Entire books have been written on each of those subjects. The author must therefore resort to extensive referencing to cover each subject adequately. Part II, Methods for Separation and Determination of Individual Elements, discusses all elements - both nonmetals and metals and major procedures for the separation and spectrophotometric determination of each element are adequately covered

  2. Validação de método analítico espectrofotométrico UV para determinação de ácido úsnico em lipossomas Validation of a UV-spectrophotometric analytical method for the determination of usnic acid in liposomes

    Directory of Open Access Journals (Sweden)

    Marigilson Pontes de Siqueira-Moura

    2008-12-01

    Full Text Available O ácido úsnico (AU é um composto de origem liquênica e tem demonstrado importantes atividades biológicas, tais como: antitumoral, antimicrobiano, antiviral, antiproliferativo e antiinflamatório. Os lipossomas são vesículas lipídicas contendo espaço aquoso interno e têm sido utilizados como carreadores coloidais de fármacos, principalmente na terapêutica de câncer e infecções bacterianas e fúngicas. O objetivo desse trabalho foi desenvolver e validar um método espectrofotométrico UV para determinação de ácido úsnico em lipossomas. Os parâmetros de validação linearidade, precisão, exatidão, robustez, limites de detecção e quantificação foram determinados segundo diretrizes internacionais de padronização e Farmacopéia Americana. A faixa de linearidade foi de 3 a 15 µg.mL-1, a equação de regressão: absorbância = 0,070 x [AU] (µg.mL-1 + 0,013 e r = 0,9997. A repetibilidade (coeficiente de variação do método foi 1,96% e a precisão intermediária indicou que a diferença entre as médias foi estatisticamente insignificante (P The secondary lichen metabolite usnic acid [2,6-diacetyl-7,9-dihydroxy-8,9b-dimethyl-1,3(2H,9bH-dibenzofuran] has demonstrated pharmacological potential activities such as antitumor, antimicrobial, antiviral, antiproliferative, and anti-inflammatory. Liposomes are vesicles composed of phospholipid bilayers surrounding aqueous compartments and they have been used as colloidal drug carriers. The aim of this study was to develop and validate a quantitative UV spectrophotometric method for determination of usnic acid in liposomal formulations. The validation parameters were assessed according to The International Conference on Harmonization (ICH and American Pharmacopoeia guidelines. The linearity range was of 3-15 µg.mL-1, regression equation: absorbance = 0.070 x UA concentration (µg.mL-1 + 0.013, and r = 0.9997. The repeatability (relative standard deviation of the method was 1.96% and

  3. Extractive Spectrophotometric Determination of Omeprazole in ...

    African Journals Online (AJOL)

    Erah

    Abstract. Purpose: To develop a simple, rapid and selective method for the extractive spectrophotometric determination of .... The colour intensity of the organic layer had shown a very .... considerable attention for quantitative analyses of many ...

  4. Spectrophotometric determination of eflornithine hydrochloride ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a spectrophotometric method for the quantitative determination of eflornithine hydrochloride as a pure compound and in pharmaceutical formulations. Methods: The method involved the reaction of the target compound with vanillin reagent at specific pH 5.6 to produce a green reddish color ...

  5. Spectrophotometric Determination of Eflornithine Hydrochloride ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a spectrophotometric method for the quantitative determination of eflornithine hydrochloride as a pure compound and in pharmaceutical formulations. Methods: The method involved the reaction of the target compound with vanillin reagent at specific pH. 5.6 to produce a green reddish color ...

  6. Extractive spectrophotometric determination of molybdenum using p-chloroisonitroso acetophenone hydrazone

    International Nuclear Information System (INIS)

    Lokhande, R.S.; Agashe, A.P.; Hundiwale, D.G.

    2001-01-01

    Separation technique like solvent extraction can be advantageously employed for the determination of metals at low concentration in micrograms using spectrophotometric methods. Hydrazoxine has been used for the extraction and spectrophotometric determination of metals at trace level as well as for the studies of transition metals in complex form. In the present paper, solvent extraction technique has been used to develop methods for the separation and spectrophotometric determination of Mo(VI) with p-chloroisonitroso acetophenone hydrazone was extracted into chloroform from aqueous solution in the pH range 8 to 8.5. The absorption maxima was also tried for the extracted species and Beer's law was also studied for its applicability. In this, interference from the foreign ion has also been examined. (author)

  7. Drosophila TRPA1 isoforms detect UV light via photochemical production of H2O2

    Science.gov (United States)

    Guntur, Ananya R.; Gu, Pengyu; Takle, Kendra; Chen, Jingyi; Xiang, Yang; Yang, Chung-Hui

    2015-01-01

    The transient receptor potential A1 (TRPA1) channel is an evolutionarily conserved detector of temperature and irritant chemicals. Here, we show that two specific isoforms of TRPA1 in Drosophila are H2O2 sensitive and that they can detect strong UV light via sensing light-induced production of H2O2. We found that ectopic expression of these H2O2-sensitive Drosophila TRPA1 (dTRPA1) isoforms conferred UV sensitivity to light-insensitive HEK293 cells and Drosophila neurons, whereas expressing the H2O2-insensitive isoform did not. Curiously, when expressed in one specific group of motor neurons in adult flies, the H2O2-sensitive dTRPA1 isoforms were as competent as the blue light-gated channelrhodopsin-2 in triggering motor output in response to light. We found that the corpus cardiacum (CC) cells, a group of neuroendocrine cells that produce the adipokinetic hormone (AKH) in the larval ring gland endogenously express these H2O2-sensitive dTRPA1 isoforms and that they are UV sensitive. Sensitivity of CC cells required dTRPA1 and H2O2 production but not conventional phototransduction molecules. Our results suggest that specific isoforms of dTRPA1 can sense UV light via photochemical production of H2O2. We speculate that UV sensitivity conferred by these isoforms in CC cells may allow young larvae to activate stress response—a function of CC cells—when they encounter strong UV, an aversive stimulus for young larvae. PMID:26443856

  8. Detection of Outliers and Imputing of Missing Values for Water Quality UV-VIS Absorbance Time Series

    OpenAIRE

    Plazas-Nossa, Leonardo; Ávila Angulo, Miguel Antonio; Torres, Andrés

    2017-01-01

    Context:The UV-Vis absorbance collection using online optical captors for water quality detection may yield outliers and/or missing values. Therefore, pre-processing to correct these anomalies is required to improve the analysis of monitoring data. The aim of this study is to propose a method to detect outliers as well as to fill-in the gaps in time series. Method:Outliers are detected using Winsorising procedure and the application of the Discrete Fourier Transform (DFT) and the Inverse of F...

  9. UV Spectrophotometric Method for theEstimation of Itopride Hydrochloride in Pharmaceutical Formulation

    Directory of Open Access Journals (Sweden)

    K. R. Gupta

    2010-01-01

    Full Text Available Three simple, precise and economical UV methods have been developed for the estimation of itopride hydrochloride in pharmaceutical formulations. Itopride hydrochloride in distilled water shows the maximum absorbance at 258.0 nm (Method A and in first order derivative spectra of the same shows sharp peak at 247.0 nm, when n = 1 (Method B. Method C utilises area under curve (AUC in the wavelength range from 262.0-254.0 nm for analysis of itopride hydrochloride. The drug was found to obey Beer-Lambert’s law in the concentration range of 5-50 μg/mL for all three proposed methods. Results of the analysis were validated statistically and recovery studies were found to be satisfactory.

  10. CVD diamond sensor for UV-photon detection

    CERN Document Server

    Periale, L; Gervino, G; Lamarina, A M; Palmisano, C; Periale, R; Picchi, P

    2012-01-01

    A new generation of UV photosensors, based on single crystal Chemical Vapour Deposition (CVD) diamonds to work optically coupled with large volume two-phase liquid-Ar (LAr) or liquid-Xe (LXe) detectors nowadays under design for the next generation of WIMPs experiments, is under development. Preliminary tests and first calibrations show these devices can have better performance than the existing UV sensitive detectors (higher photosensitivity and better signal-to-noise ratio). I-V characteristics, dark current measurements, linearity response to X-ray irradiation, and alpha-particle energy resolution are reported and discussed. (C) 2011 Elsevier B.V. All rights reserved.

  11. Analysis of Poly-β-Hydroxybutyrate in Rhizobium japonicum Bacteroids by Ion-Exclusion High-Pressure Liquid Chromatography and UV Detection

    Science.gov (United States)

    Karr, Dale B.; Waters, James K.; Emerich, David W.

    1983-01-01

    Ion-exclusion high-pressure liquid chromatography (HPLC) was used to measure poly-β-hydroxybutyrate (PHB) in Rhizobium japonicum bacteroids. The products in the acid digest of PHB-containing material were fractionated by HPLC on Aminex HPX-87H ion-exclusion resin for organic acid analysis. Crotonic acid formed from PHB during acid digestion was detected by its intense absorbance at 210 nm. The Aminex-HPLC method provides a rapid and simple chromatographic technique for routine analysis of organic acids. Results of PHB analysis by Aminex-HPLC were confirmed by gas chromatography and spectrophotometric analysis. PMID:16346443

  12. Reactivation of UV- and γ-irradiated herpes virus in UV- and X-irradiated CV-1 cells

    International Nuclear Information System (INIS)

    Takimoto, K.; Niwa, O.; Sugahara, T.

    1982-01-01

    Enhanced reactivation of UV- and γ-irradiated herpes virus was investigated by the plaque assay on CV-1 monkey kidney monolayer cells irradiated with UV light or X-rays. Both UV- and X-irradiated CV-1 cells showed enhancement of survival of UV-irradiated virus, while little or no enhancement was detected for γ-irradiated virus assayed on UV- or X-irradiated cells. The enhanced reactivation of UV-irradiated virus was greater when virus infection was delayed 24 or 48 h, than for infection immediately following the irradiation of cells. Thus the UV- or X-irradiated CV-1 cells are able to enhance the repair of UV damaged herpes virus DNA, but not of γ-ray damaged ones. (author)

  13. Enhanced detection of nitrogen dioxide via combined heating and pulsed UV operation of indium oxide nano-octahedra

    Directory of Open Access Journals (Sweden)

    Oriol Gonzalez

    2016-10-01

    Full Text Available We report on the use of combined heating and pulsed UV light activation of indium oxide gas sensors for enhancing their performance in the detection of nitrogen dioxide in air. Indium oxide nano-octahedra were synthesized at high temperature (900 °C via vapour-phase transport and screen-printed onto alumina transducers that comprised interdigitated electrodes and a heating resistor. Compared to the standard, constant temperature operation of the sensor, mild heating (e.g., 100 °C together with pulsed UV light irradiation employing a commercially available, 325 nm UV diode (square, 1 min period, 15 mA drive current signal, results in an up to 80-fold enhancement in sensitivity to nitrogen dioxide. Furthermore, this combined operation method allows for making savings in power consumption that range from 35% to over 80%. These results are achieved by exploiting the dynamics of sensor response under pulsed UV light, which convey important information for the quantitative analysis of nitrogen dioxide.

  14. Enhanced detection of nitrogen dioxide via combined heating and pulsed UV operation of indium oxide nano-octahedra.

    Science.gov (United States)

    Gonzalez, Oriol; Roso, Sergio; Vilanova, Xavier; Llobet, Eduard

    2016-01-01

    We report on the use of combined heating and pulsed UV light activation of indium oxide gas sensors for enhancing their performance in the detection of nitrogen dioxide in air. Indium oxide nano-octahedra were synthesized at high temperature (900 °C) via vapour-phase transport and screen-printed onto alumina transducers that comprised interdigitated electrodes and a heating resistor. Compared to the standard, constant temperature operation of the sensor, mild heating (e.g., 100 °C) together with pulsed UV light irradiation employing a commercially available, 325 nm UV diode (square, 1 min period, 15 mA drive current signal), results in an up to 80-fold enhancement in sensitivity to nitrogen dioxide. Furthermore, this combined operation method allows for making savings in power consumption that range from 35% to over 80%. These results are achieved by exploiting the dynamics of sensor response under pulsed UV light, which convey important information for the quantitative analysis of nitrogen dioxide.

  15. Spectrophotometric determination of volautile inorganic hydrides in binary gaseous mixtures

    International Nuclear Information System (INIS)

    Rezchikov, V.G.; Skachkova, I.N.; Kuznetsova, T.S.; Khrushcheva, V.V.

    1985-01-01

    A study was made on possibility of single and continuons analysis of binary mixtures (hydride-gas) for the content of volatile inorganic hydrides (VIH) from absorption spectra in the 185-280 nm band. Dependences of the percentage of VIH transmission on the wavelength are presented. It is shown that the maximum of their absorption depends on the element-hydrogen the bond length and binding energy. Detection limit for boron hydride was established to be n x 10 -3 % vol at 185-190 nm wavelength. Technique for spectrophotometric hydride determination in binary mixtures with hydrogen, argon, helium was developed. The technique provides the continuous control of gaseous mixture composition

  16. Extraction spectrophotometric analyzer

    International Nuclear Information System (INIS)

    Batik, J.; Vitha, F.

    1985-01-01

    Automation is discussed of extraction spectrophotometric determination of uranium in a solution. Uranium is extracted from accompanying elements in an HCl medium with a solution of tributyl phosphate in benzene. The determination is performed by measuring absorbance at 655 nm in a single-phase ethanol-water-benzene-tributyl phosphate medium. The design is described of an analyzer consisting of an analytical unit and a control unit. The analyzer performance promises increased productivity of labour, improved operating and hygiene conditions, and mainly more accurate results of analyses. (J.C.)

  17. Determination of loratadine in pharmaceuticals by a spectrophotometric method

    Directory of Open Access Journals (Sweden)

    Pavalache Georgeta

    2015-06-01

    Full Text Available The spectrophotometric method for determination of loratadine using tetraiodomercurate has been applied in various pharmaceutical formulations. The results confirmed that recovery value is optimum and the method is valid, thus it can be used in quality control and evaluation of loratadine tablets, oral formulations of mixed composition, oral solutions, etc. The method is easy and simple to apply, does not require complicated equipment and spectrophotometric reading time is reduced, which allows a large number of analyzes in a relatively short time.

  18. Kinetic spectrophotometric determination of some fluoroquinolone ...

    African Journals Online (AJOL)

    A simple and sensitive kinetic spectrophotometric method was developed for the determination of some fluoroquinolonea antibiotics; gemifloxacin mesylate, moxifloxacin hydrochloride and gatifloxacin in bulk and in pharmaceutical preparations. The method is based upon a kinetic investigation of the oxidation reaction of ...

  19. Kinetic Spectrophotometric Determination of Trace Amounts of Sulfide

    Energy Technology Data Exchange (ETDEWEB)

    Barzegar, Mohsen [Tarbiat Modarres University, Tehran (Iran, Islamic Republic of); Jabbari, Ali [K. N. Toosi University, Tehran (Iran, Islamic Republic of); Esmaeili, Majid [Razi University, Kermanshah (Iran, Islamic Republic of)

    2003-09-15

    A method for the determination of trace amount of sulfide based on the addition reaction of sulfide with methyl green at pH 7.5 and 25 .deg. C is described. The reaction is monitored spectrophotometrically by measuring the decrease in absorbance of the dyestuff at 637 nm by the initial rate and fixed time method. The calibration graph is linear in the range 30-1200 ppb. The theoretical limit of detection was 0.014 ppm. Seven replicate analysis of a sample solution containing 0.70 ppm sulfide gave a relative standard deviation of 1.5%. The interfering effects of various ions on sulfide determination have been reported and procedures for removal of interference have been described. The proposed method was applied successfully to the determination of sulfide in tap and wastewater samples.

  20. Kinetic Spectrophotometric Determination of Trace Amounts of Sulfide

    International Nuclear Information System (INIS)

    Barzegar, Mohsen; Jabbari, Ali; Esmaeili, Majid

    2003-01-01

    A method for the determination of trace amount of sulfide based on the addition reaction of sulfide with methyl green at pH 7.5 and 25 .deg. C is described. The reaction is monitored spectrophotometrically by measuring the decrease in absorbance of the dyestuff at 637 nm by the initial rate and fixed time method. The calibration graph is linear in the range 30-1200 ppb. The theoretical limit of detection was 0.014 ppm. Seven replicate analysis of a sample solution containing 0.70 ppm sulfide gave a relative standard deviation of 1.5%. The interfering effects of various ions on sulfide determination have been reported and procedures for removal of interference have been described. The proposed method was applied successfully to the determination of sulfide in tap and wastewater samples

  1. Diurnal changes in epidermal UV transmittance of plants in naturally high UV environments.

    Science.gov (United States)

    Barnes, Paul W; Flint, Stephan D; Slusser, James R; Gao, Wei; Ryel, Ronald J

    2008-06-01

    Studies were conducted on three herbaceous plant species growing in naturally high solar UV environments in the subalpine of Mauna Kea, Hawaii, USA, to determine if diurnal changes in epidermal UV transmittance (T(UV)) occur in these species, and to test whether manipulation of the solar radiation regime could alter these diurnal patterns. Additional field studies were conducted at Logan, Utah, USA, to determine if solar UV was causing diurnal T(UV) changes and to evaluate the relationship between diurnal changes in T(UV) and UV-absorbing pigments. Under clear skies, T(UV), as measured with a UV-A-pulse amplitude modulation fluorometer for leaves of Verbascum thapsus and Oenothera stricta growing in native soils and Vicia faba growing in pots, was highest at predawn and sunset and lowest at midday. These patterns in T(UV) closely tracked diurnal changes in solar radiation and were the result of correlated changes in fluorescence induced by UV-A and blue radiation but not photochemical efficiency (F(v)/F(m)) or initial fluorescence yield (F(o)). The magnitude of the midday reduction in T(UV) was greater for young leaves than for older leaves of Verbascum. Imposition of artificial shade eliminated the diurnal changes in T(UV) in Verbascum, but reduction in solar UV had no effect on diurnal T(UV) changes in Vicia. In Vicia, the diurnal changes in T(UV) occurred without detectable changes in the concentration of whole-leaf UV-absorbing compounds. Results suggest that plants actively control diurnal changes in UV shielding, and these changes occur in response to signals other than solar UV; however, the underlying mechanisms responsible for rapid changes in T(UV) remain unclear.

  2. New development of spectrophotometric analysis of thorium

    International Nuclear Information System (INIS)

    Yang Xiangzhen

    1992-01-01

    This review covers new development of spectrophotometric determination of thorium since 1980's. The methods include general spectrophotometry, double wavelength spectrophotometry, catalytic spectrophotometry, total differential spectrophotometry, derivative spectrophotometry and fluorescent spectrophotometry, etc

  3. Stopped-flow injection spectrophotometric method for determination of chlorate in soil

    Directory of Open Access Journals (Sweden)

    Jaroon Jakmunee

    2008-06-01

    Full Text Available A stopped-flow injection (FI spectrophotometric procedure based on iodometric reaction for the determination of chlorate has been developed. Standard/sample was injected into a stream of potassium iodide solution and then merged with a stream of hydrochloric acid solution to produce triiodide. By stopping the flow while the sample zone is being in a mixing coil, a slow reaction of chlorate with iodide in acidic medium was promoted to proceed with minimal dispersion of the triiodide product zone. When the flow started again, a concentrated product zone was pushed into a flow cell and a signal profile due to light absorption of the product was recorded. Employing a lab-built semi-automatic stopped-FI analyser, the analysis can be performed with higher degree of automation and low chemical consumption. Linear calibration graph in the range of 5-50 mg ClO3- L-1 was obtained, with detection limit of 1.4 mg ClO3- L-1. Relative standard deviation of 2.2% (30 mg ClO3- L-1, n=10 and sample throughput of about 20 h-1 were achieved. The system was applied to soil samples and validated by batch spectrophotometric and standard titrimetric methods.

  4. Spectrophotometric determination of Fe(II) in Geological Materials by Using Ferrozine as Cromogenic Reagent

    International Nuclear Information System (INIS)

    Sanchez, D. M.; Martin, R.; Marin, J.; Morante, R.; Gutierrez, L.; Bayon, A.

    1999-12-01

    A rapid and sensitive spectrophotometric method for the determination of labile ferrous iron in geological materials is described. Samples are treated by boiling with hydrochloric acid for 60 min. in an atmosphere of carbon dioxide. Systematic erroneous results due to high concentrations of ferric iron are resolved. The limit of detection for the method was 0.02% of FeO. International standard granites analysed by the proposed method showed recoveries ranged from 81-102%. (Author) 9 refs

  5. Spectrophotometric determination of uranium using quercetin

    International Nuclear Information System (INIS)

    Barros, A.R.

    1972-10-01

    A spectrophotometric method for quantitative determination of uranium, using a flavone (quercetin) as complexing agent, is described. The method is based on the reaction between uranyl ion and alcoholic solution of quercetin with a complex formation of intense yellow color. (M.C.L.) [pt

  6. Headspace single-drop microextraction coupled to microvolume UV-vis spectrophotometry for iodine determination

    International Nuclear Information System (INIS)

    Pena-Pereira, Francisco; Lavilla, Isela; Bendicho, Carlos

    2009-01-01

    Headspace single-drop microextraction has been combined with microvolume UV-vis spectrophotometry for iodine determination. Matrix separation and preconcentration of iodide following in situ volatile iodine generation and extraction into a microdrop of N,N'-dimethylformamide is performed. An exhaustive characterization of the microextraction system and the experimental variables affecting iodine generation from iodide was carried out. The procedure employed consisted of exposing 2.5 μL of N,N'-dimethylformamide to the headspace of a 10 mL acidic (H 2 SO 4 2 mol L -1 ) aqueous solution containing 1.7 mol L -1 Na 2 SO 4 for 7 min. Addition of 1 mL of H 2 O 2 1 mol L -1 for in situ iodine generation was performed. The limit of detection was determined as 0.69 μg L -1 . The repeatability, expressed as relative standard deviation, was 4.7% (n = 6). The calibration working range was from 5 to 200 μg L -1 (r 2 = 0.9991). The large preconcentration factor obtained, ca. 623 in only 7 min, compensate for the 10-fold loss in sensitivity caused by the decreased optical path, which results in improved detection limits as compared to spectrophotometric measurements carried out with conventional sample cells. The method was successfully applied to the determination of iodine in water, pharmaceutical and food samples

  7. Spectrophotometric Determination Of Heavy Metals In Cosmetics

    African Journals Online (AJOL)

    ISSN 1597-6343. Spectrophotometric Determination Of Heavy Metals In Cosmetics ... analysed using atomic absorption spectrophotometer – coupled with a hydride ... presence of arsenic (As), mercury (Hg), cadmium (Cd) and lead. (Pb) in ...

  8. Spectrophotometric Analysis of Phosphoric Acid Leakage in High-Temperature Phosphoric Acid-Doped Polybenzimidazole Membrane Fuel Cell Application

    Directory of Open Access Journals (Sweden)

    Seungyoon Han

    2016-01-01

    Full Text Available High-temperature proton exchange membrane fuel cells (HT-PEMFCs utilize a phosphoric acid- (PA- doped polybenzimidazole (PBI membrane as a polymer electrolyte. The PA concentration in the membrane can affect fuel cell performance, as a significant amount of PA can leak from the membrane electrode assembly (MEA by dissolution in discharged water, which is a byproduct of cell operation. Spectrophotometric analysis of PA leakage in PA-doped polybenzimidazole membrane fuel cells is described here. This spectrophotometric analysis is based on measurement of absorption of an ion pair formed by phosphomolybdic anions and the cationoid color reagent. Different color reagents were tested based on PA detection sensitivity, stability of the formed color, and accuracy with respect to the amount of PA measured. This method allows for nondestructive analysis and monitoring of PA leakage during HT-PEMFCs operation.

  9. Development of Ultraviolet Spectrophotometric Method for Analysis ...

    African Journals Online (AJOL)

    HP

    Method for Analysis of Lornoxicam in Solid Dosage. Forms. Sunit Kumar Sahoo ... testing. Mean recovery was 100.82 % for tablets. Low values of % RSD indicate .... Saharty E, Refaat YS, Khateeb ME. Stability-. Indicating. Spectrophotometric.

  10. Autofluorescence of pigmented skin lesions using a pulsed UV laser with synchronized detection: clinical results

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Svenmarker, Pontus; Tidemand-Lichtenberg, Peter

    2010-01-01

    signal, which may in turn produce high contrast images that improve diagnosis, even in the presence of ambient room light. The synchronized set-up utilizes a compact, diode pumped, pulsed UV laser at 355 nm which is coupled to a CCD camera and a liquid crystal tunable filter. The excitation and image......We report preliminary clinical results of autofluorescence imaging of malignant and benign skin lesions, using pulsed 355 nm laser excitation with synchronized detection. The novel synchronized detection system allows high signal-to-noise ratio to be achieved in the resulting autofluorescence...

  11. Spectrophotometric determination of fluoride with alizarin complexone

    Energy Technology Data Exchange (ETDEWEB)

    Marczenko, Z; Lenarczyk, L [Politechnika Warszawska (Poland)

    1976-01-01

    The modification of direct spectrophotometric method of fluoride determination by alizarin complexone has been developed. It was shown that the lanthanum alizarin complexone chelate is more convenient than that of cerium (3). The influence of acetone, dioxane and dimethyl sulphoxide in water solution on the increase of sensitivity of the method and the rate of colour reaction has been determined. The optimal pH ranges for the reaction with lanthanum and cerium (3) have been estimated. Some amines having a large molecule are useful for extraction of blue fluoride complex with isobutanol. Dioctylamine was applied in a new extraction spectrophotometric procedure of fluoride determination. Conditions in reagent have been established. Both variants of the method have been applied to the fluoride determination in several chemicals. The obtained results show a good precision and accuracy.

  12. Organic conjugated small molecule materials based optical probe for rapid, colorimetric and UV-vis spectral detection of phosphorylated protein in placental tissue.

    Science.gov (United States)

    Wang, Yanfang; Yang, Na; Liu, Yi

    2018-04-05

    A novel organic small molecule with D-Pi-A structure was prepared, which was found to be a promising colorimetric and ratiometric UV-vis spetral probe for detection of phosphorylated proteins with the help of tetravalent zirconium ion. Such optical probe based on chromophore WYF-1 shows a rapid response (within 10s) and high selectivity and sensitivity for phosphorylated proteins, giving distinct colorimetric and ratiometric UV-vis changes at 720 and 560nm. The detection limit for phosphorylated proteins was estimated to be 100nM. In addition, detection of phosphorylated proteins in placental tissue samples with this probe was successfully applied, which indicates that this probe holds great potential for phosphorylated proteins detection. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Detection of olive oil adulteration by low-field NMR relaxometry and UV-Vis spectroscopy upon mixing olive oil with various edible oils

    Directory of Open Access Journals (Sweden)

    S. Ok

    2017-03-01

    Full Text Available Adulteration of olive oil using unhealthy substitutes is considered a threat for public health. Low-field (LF proton (1H nuclear magnetic resonance (NMR relaxometry and ultra-violet (UV visible spectroscopy are used to detect adulteration of olive oil. Three different olive oil with different oleoyl acyl contents were mixed with almond, castor, corn, and sesame oils with three volumetric ratios, respectively. In addition, Arbequina olive oil was mixed with canola, flax, grape seed, peanut, soybean, and sunflower seed oils with three volumetric ratios. Transverse magnetization relaxation time (T2 curves were fitted with bi-exponential decaying functions. T2 times of each mixture of olive oils and castor oils, and olive oils and corn oils changed systematically as a function of volumetric ratio. To detect the adulteration in the mixtures with almond and sesame oils, both LF 1H NMR relaxometry and UV-Vis spectroscopy were needed, where UV-Vis-spectroscopy detected the adulteration qualitatively. In the mixtures of Arbequina olive oil and flax, peanut, soybean, and sunflower seed oils, both T21 and T22 values became longer systematically as the content of the olive oil was decreased. The unique UV-Vis maximum absorbance of flax oil at 320.0 nm shows the adulteration of olive oil qualitatively.

  14. Detection of olive oil adulteration by low-field NMR relaxometry and UV-Vis spectroscopy upon mixing olive oil with various edible oils

    International Nuclear Information System (INIS)

    Ok, S.

    2017-01-01

    Adulteration of olive oil using unhealthy substitutes is considered a threat for public health. Low-field (LF) proton (1H) nuclear magnetic resonance (NMR) relaxometry and ultra-violet (UV) visible spectroscopy are used to detect adulteration of olive oil. Three different olive oil with different oleoyl acyl contents were mixed with almond, castor, corn, and sesame oils with three volumetric ratios, respectively. In addition, Arbequina olive oil was mixed with canola, flax, grape seed, peanut, soybean, and sunflower seed oils with three volumetric ratios. Transverse magnetization relaxation time (T2) curves were fitted with bi-exponential decaying functions. T2 times of each mixture of olive oils and castor oils, and olive oils and corn oils changed systematically as a function of volumetric ratio. To detect the adulteration in the mixtures with almond and sesame oils, both LF 1H NMR relaxometry and UV-Vis spectroscopy were needed, where UV-Vis-spectroscopy detected the adulteration qualitatively. In the mixtures of Arbequina olive oil and flax, peanut, soybean, and sunflower seed oils, both T21 and T22 values became longer systematically as the content of the olive oil was decreased. The unique UV-Vis maximum absorbance of flax oil at 320.0 nm shows the adulteration of olive oil qualitatively. [es

  15. Effect of far-UV and near-UV radiation on the cell surface charge of the protozoan Tritrichomonas foetus

    Energy Technology Data Exchange (ETDEWEB)

    Silva Filho, F C; Elias, C A; Souza, W de

    1986-05-01

    Cell electrophoresis was used to detect the effect of far-UV or near-UV radiation on the cell surface charge of the pathogenic protozoan Tritrichomonas foetus. Either far-UV or near-UV radiation interfered with the surface charge of T. foetus at fluences which inhibited cell growth by 50%. Both UV-radiations induced a significant decrease on surface charge of T. foetus, as evaluated by measurement of its electrophoretic mobility (EPM). Determinations of EPM of protozoa in solution of low ionic strength indicated that the decrease in the EPM induced by far-UV is much less pronounced that that observed for near-UV or control cells.

  16. Effect of far-UV and near-UV radiation on the cell surface charge of the protozoan Tritrichomonas foetus

    International Nuclear Information System (INIS)

    Silva Filho, F.C.; Elias, C.A.; Souza, W. de

    1986-01-01

    Cell electrophoresis was used to detect the effect of far-UV or near-UV radiation on the cell surface charge of the pathogenic protozoan Tritrichomonas foetus. Either far-UV or near-UV radiation interfered with the surface charge of T. foetus at fluences which inhibited cell growth by 50%. Both UV-radiations induced a significant decrease on surface charge of T. foetus, as evaluated by measurement of its electrophoretic mobility (EPM). Determinations of EPM of protozoa in solution of low ionic strength indicated that the decrease in the EPM induced by far-UV is much less pronounced that that observed for near-UV or control cells. (author)

  17. A new optical sensor for spectrophotometric determination of uranium (VI) and thorium (IV) in acidic medium

    Energy Technology Data Exchange (ETDEWEB)

    Elhefnawy, O.A. [Nuclear and Radiological Regulatory Authority (NRRA), Cairo (Egypt). Nuclear Safeguards and Physical Protection Dept.

    2017-07-01

    A spectrophotometric method was developed for U(VI) and Th(IV) determination in acidic medium by using proposed optical sensor. This sensor is base on the complexation reaction of the ionophore midodrine hydrochloride (L) with U(VI)/Th(IV) in plasticized (o-NPOE) high molecular weight (PVC). Several parameters such as effect of acidic medium, response time and sensor compositions were studied. The determination of the complexes stoichiometry was also studied using Job's method. The complexes stoichiometry were measured at the absorbance spectra 302 nm and the results were found to be 1:1 for both complexes U(VI)-L and Th(IV)-L. The complexation reaction was extremely rapid at room temperature; it takes 5, 10 min to complete the complexation reaction in U(VI) and Th(IV), respectively. Under the optimum conditions the calibration curves of U(VI)/Th(IV) determination, have good linearity at different acidic medium nitric, sulfuric, and phosphoric acids with low detection and quantification limits. The accuracy and precision studies proved that the proposed optical sensor is valid and qualified for U(VI)/Th(IV) spectrophotometric determination in different acidic medium. The selectivity of the proposed optical sensor was studied. The proposed optical sensor was applied successfully for U(VI)/Th(IV) determination in research and development (R and D) nuclear waste samples with satisfactory results. A comparative study of the proposed optical sensor with other previous spectrophotometric sensors for U(VI)/Th(IV) determination, proved the high efficiency of the proposed optical sensor, that it presents wide linear range and low detection limit. The proposed optical sensor could be applied for a quantitative determination of U(VI)/Th(IV) in acidic waste samples.

  18. A new optical sensor for spectrophotometric determination of uranium (VI) and thorium (IV) in acidic medium

    International Nuclear Information System (INIS)

    Elhefnawy, O.A.

    2017-01-01

    A spectrophotometric method was developed for U(VI) and Th(IV) determination in acidic medium by using proposed optical sensor. This sensor is base on the complexation reaction of the ionophore midodrine hydrochloride (L) with U(VI)/Th(IV) in plasticized (o-NPOE) high molecular weight (PVC). Several parameters such as effect of acidic medium, response time and sensor compositions were studied. The determination of the complexes stoichiometry was also studied using Job's method. The complexes stoichiometry were measured at the absorbance spectra 302 nm and the results were found to be 1:1 for both complexes U(VI)-L and Th(IV)-L. The complexation reaction was extremely rapid at room temperature; it takes 5, 10 min to complete the complexation reaction in U(VI) and Th(IV), respectively. Under the optimum conditions the calibration curves of U(VI)/Th(IV) determination, have good linearity at different acidic medium nitric, sulfuric, and phosphoric acids with low detection and quantification limits. The accuracy and precision studies proved that the proposed optical sensor is valid and qualified for U(VI)/Th(IV) spectrophotometric determination in different acidic medium. The selectivity of the proposed optical sensor was studied. The proposed optical sensor was applied successfully for U(VI)/Th(IV) determination in research and development (R and D) nuclear waste samples with satisfactory results. A comparative study of the proposed optical sensor with other previous spectrophotometric sensors for U(VI)/Th(IV) determination, proved the high efficiency of the proposed optical sensor, that it presents wide linear range and low detection limit. The proposed optical sensor could be applied for a quantitative determination of U(VI)/Th(IV) in acidic waste samples.

  19. Uranium fluorides analysis. Titanium spectrophotometric determination

    International Nuclear Information System (INIS)

    Anon.

    Titanium determination in uranium hexafluoride in the range 0.7 to 100 microgrammes after transformation of uranium fluoride in sulfate. Titanium is separated by extraction with N-benzoylphenylhydroxylamine, reextracted by hydrochloric-hydrofluoric acid. The complex titanium-N-benzoylphenylhydroxylamine is extracted by chloroform. Spectrophotometric determination at 400 nm [fr

  20. Spectrophotometric determination of triclosan in personal care products

    Science.gov (United States)

    Lu, Huihui; Ma, Hongbing; Tao, Guanhong

    2009-09-01

    A spectrophotometric method for the determination of triclosan in personal care products was proposed. It was based on the reaction of sodium nitrite with p-sulfanilic acid in an acidic medium to form diazonium ion, with which triclosan further formed an azo compound in an alkaline medium. The resulting yellow colored product has a maximum absorption at 452 nm. A good linear relationship ( r = 0.9999) was obtained in the range of 0-30 mg L -1 triclosan. A detection limit of 0.079 g L -1 was achieved and the relative standard deviation was 0.24% ( n = 11) at 14 mg L -1 triclosan. The proposed method has been applied to the analyses of triclosan in several personal care products and the results were in good agreement with those obtained by high-performance liquid chromatography.

  1. SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF MONTELUKAST SODIUM AND BAMBUTEROL HYDROCHLORIDE IN TABLETS

    OpenAIRE

    Patel Satish A; Patel Dhara J; Patel Natavarlal J.

    2011-01-01

    The present manuscript describe simple, sensitive, rapid, accurate, precise and economical first derivative spectrophotometric method for the simultaneous determination of montelukast sodium and bambuterol hydrochloride in combined tablet dosage form. The derivative spectrophotometric method was based on the determination of both the drugs at their respective zero crossing point (ZCP). The first order derivative spectra was obtained in chloroform and the determinations were made at 241 nm (ZC...

  2. Spectrophotometric determination of proteins associated with ...

    African Journals Online (AJOL)

    Twenty six Aeromonas isolates from fishes, poultry and humans in Zaria were quantified for total soluble proteins (enzymes) profiles in January, 2007 by spectrophotometric (Biuret) method. Isolates were grown on Brain Heart Infusion (BHI) broth, they were incubated at 370C and centrifuged at 1,000 g/dl using harous ...

  3. Spectrophotometric determination of uranium by previous extraction chromatography separation in polimetalic mineral, phosphorites and technological licours

    International Nuclear Information System (INIS)

    Moreno Bermudez, J.; Cabrera Quevedo, C.; Alfonso Mendez, L.; Rodriguez Aguilera, M.

    1994-01-01

    The development of an analytical procedure for spectrophotometric determination of uranium in polimetalic mineral, phosphorites and technological licours is described. The method is based on the previous separation of interfering elements by extraction chromatography and on spectrophotometric determination of uranium (IV) with arsenazo III in concentrated hydrochloric acid. Tributyl phosphate impregnate on politetrafluoroethylene is used as stationary phase and 5.5 M nitric acid is used as movie phase. The influence of matrix-component elements was studies. The development procedure was applied to real samples, being the results compared with those obtained by other well established analytical methods like gamma-spectrometry, laser fluorimetric, spectrophotometry previous uranium separation by liquid liquid extraction and anion exchange. The reproducibility is evaluated and the detection limited has been established for each studied matrix. A procedure for correcting the thorium interference has been developed for samples with a Th/ 3U8O higher than 0.2

  4. A New Technique for Quantitative Determination of Dexamethasone in Pharmaceutical and Biological Samples Using Kinetic Spectrophotometric Method

    Directory of Open Access Journals (Sweden)

    Ali Mohammad Akhoundi-Khalafi

    2015-01-01

    Full Text Available Dexamethasone is a type of steroidal medications that is prescribed in many cases. In this study, a new reaction system using kinetic spectrophotometric method for quantitative determination of dexamethasone is proposed. The method is based on the catalytic effect of dexamethasone on the oxidation of Orange G by bromate in acidic media. The change in absorbance as a criterion of the oxidation reaction progress was followed spectrophotometrically. To obtain the maximum sensitivity, the effective reaction variables were optimized. Under optimized experimental conditions, calibration graph was linear over the range 0.2–54.0 mg L−1. The calculated detection limit (3sb/m was 0.14 mg L−1 for six replicate determinations of blank signal. The interfering effect of various species was also investigated. The present method was successfully applied for the determination of dexamethasone in pharmaceutical and biological samples satisfactorily.

  5. Verification of spectrophotometric method for nitrate analysis in water samples

    Science.gov (United States)

    Kurniawati, Puji; Gusrianti, Reny; Dwisiwi, Bledug Bernanti; Purbaningtias, Tri Esti; Wiyantoko, Bayu

    2017-12-01

    The aim of this research was to verify the spectrophotometric method to analyze nitrate in water samples using APHA 2012 Section 4500 NO3-B method. The verification parameters used were: linearity, method detection limit, level of quantitation, level of linearity, accuracy and precision. Linearity was obtained by using 0 to 50 mg/L nitrate standard solution and the correlation coefficient of standard calibration linear regression equation was 0.9981. The method detection limit (MDL) was defined as 0,1294 mg/L and limit of quantitation (LOQ) was 0,4117 mg/L. The result of a level of linearity (LOL) was 50 mg/L and nitrate concentration 10 to 50 mg/L was linear with a level of confidence was 99%. The accuracy was determined through recovery value was 109.1907%. The precision value was observed using % relative standard deviation (%RSD) from repeatability and its result was 1.0886%. The tested performance criteria showed that the methodology was verified under the laboratory conditions.

  6. Deep UV emitting scintillators for alpha and beta particle detection

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Y. [Department of Physics and Astronomy, University of Georgia, Athens, GA 30606 (United States); Jia, D.D.; Lewis, L.A. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Feofilov, S.P. [A.F. Ioffe Physical-Technical Institute, St. Petersburg, 194021 (Russian Federation); Meltzer, R.S., E-mail: rmeltzer@physast.uga.ed [Department of Physics and Astronomy, University of Georgia, Athens, GA 30606 (United States)

    2011-03-21

    Several deep UV emitting scintillators, whose emission falls in the solar blind region of the spectrum (200-280 nm), are described and their scintillator properties are characterized. They include LaPO{sub 4}:Pr, YPO{sub 4}:Pr, YAlO{sub 3}:Pr, Pr(PO{sub 3}){sub 3}, YPO{sub 4}:Bi and ScPO{sub 4}. These materials would facilitate the detection of ionizing radiation in open areas, even during the daylight hours, and could be used to support large area surveys that monitor for the presence of ionization radiation due, for example, to system leaks or transfer contamination. These materials can be used in the form of powders, thin films or paints for radiation detection. They are characterized for both beta radiation using electron beams (2-35 keV) and {sup 137}Cs and alpha radiations using {sup 241}Am sources. Their absolute light yields are estimated and are compared to that of Y{sub 2}SiO{sub 5}:Ce. Their light yields decrease as a function of electron energy but at 10 keV they approach 8000 ph/MeV.

  7. SPECTROPHOTOMETRIC DETERMINATION OF NITRITE BY ITS ...

    African Journals Online (AJOL)

    Preferred Customer

    sources of nitrite include intensive use of chemical nitrogenous fertilizers, ... The current paper describes another kinetic spectrophotometric method for determination of ... s at λmax = 570 nm (allowing a lag time of 5 s) against water as reference. ... samples and the total amount of the analyte was estimated by applying the ...

  8. Validation of different spectrophotometric methods for determination of vildagliptin and metformin in binary mixture

    Science.gov (United States)

    Abdel-Ghany, Maha F.; Abdel-Aziz, Omar; Ayad, Miriam F.; Tadros, Mariam M.

    New, simple, specific, accurate, precise and reproducible spectrophotometric methods have been developed and subsequently validated for determination of vildagliptin (VLG) and metformin (MET) in binary mixture. Zero order spectrophotometric method was the first method used for determination of MET in the range of 2-12 μg mL-1 by measuring the absorbance at 237.6 nm. The second method was derivative spectrophotometric technique; utilized for determination of MET at 247.4 nm, in the range of 1-12 μg mL-1. Derivative ratio spectrophotometric method was the third technique; used for determination of VLG in the range of 4-24 μg mL-1 at 265.8 nm. Fourth and fifth methods adopted for determination of VLG in the range of 4-24 μg mL-1; were ratio subtraction and mean centering spectrophotometric methods, respectively. All the results were statistically compared with the reported methods, using one-way analysis of variance (ANOVA). The developed methods were satisfactorily applied to analysis of the investigated drugs and proved to be specific and accurate for quality control of them in pharmaceutical dosage forms.

  9. Spectrophotometric reading of EUCAST antifungal susceptibility testing of Aspergillus fumigatus

    DEFF Research Database (Denmark)

    Meletiadis, J.; Leth Mortensen, K.; Verweij, P. E.

    2017-01-01

    with spectrophotometrically determined MICs and essential (±1 twofold dilution) and categorical (susceptible/intermediate/resistant or wild-type/non-wild-type) agreement was calculated. Spectrophotometric data were analysed with regression analysis using the Emax model, and the effective concentration corresponding to 5% (EC......5) was estimated. Results Using the 5% cut-off, high essential (92%–97%) and categorical (93%–99%) agreement (

  10. Batch and flow-injection methods for the spectrophotometric determination of olanzapine

    Energy Technology Data Exchange (ETDEWEB)

    Jasinska, A.; Nalewajko, E

    2004-04-22

    An indirect batch spectrophotometric and direct flow-injection (FI) visible spectrophotometric methods have been developed for the determination of the novel anti-psychotic drug olanzapine (OLA). The batch method is based on the oxidation of olanzapine by a known excess of potassium hexacyanoferrate(III) in the presence of the mixture of sulphuric and phosphoric acids (1:1 (v/v)). The absorbance of unreacted oxidant is measured at 425 nm. The absorbance decreases linearly with increasing concentration of the assayed drug. The FI method with detection at 540 nm is based on the direct oxidation of olanzapine one of two oxidants, cerium(IV) sulphate or potassium hexacyanoferrate(III) in acidic medium. The calibration graph were linear over the range of 2.5-40 {mu}g ml{sup -1} in the batch method and 0.05-300 and 0.5-250 {mu}g ml{sup -1} in the FI methods, used cerium (IV) sulphate and potassium hexacyanoferrate (III) respectively. Both FI methods gave similar results in terms of precision and accuracy. The relative standard deviation (R.S.D.), was <1%. The accuracy, obtained from recovery experiments, was 97.9-99.4%. The batch method gave slightly higher R.S.D. values (up to 2.3%) and lower values of accuracy (the recovery was between 96.5 and 96.6%). The methods developed were applied to the determination of olanzapine in a pharmaceutical product.

  11. Study on the Solid Phase Extraction and Spectrophotometric ...

    African Journals Online (AJOL)

    NJD

    Spectrophotometric Determination of Mercury in Water and. Biological ... 1Department of Chemistry, Yunnan University, Kunming, 650091, P.R. China. 2Department of ... (such as higher enrichment factor, reduced contamination of the.

  12. Final LDRD report : development of advanced UV light emitters and biological agent detection strategies.

    Energy Technology Data Exchange (ETDEWEB)

    Figiel, Jeffrey James; Crawford, Mary Hagerott; Banas, Michael Anthony; Farrow, Darcie; Armstrong, Andrew M.; Serkland, Darwin Keith; Allerman, Andrew Alan; Schmitt, Randal L.

    2007-12-01

    We present the results of a three year LDRD project which has focused on the development of novel, compact, ultraviolet solid-state sources and fluorescence-based sensing platforms that apply such devices to the sensing of biological and nuclear materials. We describe our development of 270-280 nm AlGaN-based semiconductor UV LEDs with performance suitable for evaluation in biosensor platforms as well as our development efforts towards the realization of a 340 nm AlGaN-based laser diode technology. We further review our sensor development efforts, including evaluation of the efficacy of using modulated LED excitation and phase sensitive detection techniques for fluorescence detection of bio molecules and uranyl-containing compounds.

  13. PCA-based algorithm for calibration of spectrophotometric analysers of food

    International Nuclear Information System (INIS)

    Morawski, Roman Z; Miekina, Andrzej

    2013-01-01

    Spectrophotometric analysers of food, being instruments for determination of the composition of food products and ingredients, are today of growing importance for food industry, as well as for food distributors and consumers. Their metrological performance significantly depends of the numerical performance of available means for spectrophotometric data processing; in particular – the means for calibration of analysers. In this paper, a new algorithm for this purpose is proposed, viz. the algorithm using principal components analysis (PCA). It is almost as efficient as PLS-based algorithms of calibration, but much simpler

  14. Visible and UV photo-detection in ZnO nanostructured thin films via simple tuning of solution method.

    Science.gov (United States)

    Khokhra, Richa; Bharti, Bandna; Lee, Heung-No; Kumar, Rajesh

    2017-11-08

    This study demonstrates significant visible light photo-detection capability of pristine ZnO nanostructure thin films possessing substantially high percentage of oxygen vacancies [Formula: see text] and zinc interstitials [Formula: see text], introduced by simple tuning of economical solution method. The demonstrated visible light photo-detection capability, in addition to the inherent UV light detection ability of ZnO, shows great dependency of [Formula: see text] and [Formula: see text] with the nanostructure morphology. The dependency was evaluated by analyzing the presence/percentage of [Formula: see text] and [Formula: see text] using photoluminescence (PL) and X-ray photoelectron spectroscopy (XPS) measurements. Morphologies of ZnO viz. nanoparticles (NPs), nanosheets (NSs) and nanoflowers (NFs), as a result of tuning of synthesis method contended different concentrations of defects, demonstrated different photo-detection capabilities in the form of a thin film photodetector. The photo-detection capability was investigated under different light excitations (UV; 380~420 nm, white ; λ > 420 nm and green; 490~570 nm). The as fabricated NSs photodetector possessing comparatively intermediate percentage of [Formula: see text] ~ 47.7% and [Formula: see text] ~ 13.8% exhibited superior performance than that of NPs and NFs photodetectors, and ever reported photodetectors fabricated by using pristine ZnO nanostructures in thin film architecture. The adopted low cost and simplest approach makes the pristine ZnO-NSs applicable for wide-wavelength applications in optoelectronic devices.

  15. Application of UV-Vis spectrophotometric and chemiluminescent methods for the evaluation of the antioxidant action of curcumin

    Czech Academy of Sciences Publication Activity Database

    Stanchev, Stancho; Pencheva, I.; Konstantinov, S.; Obreshkova, D.; Hadjimitova, V.

    2012-01-01

    Roč. 77, č. 8 (2012), s. 1063-1069 ISSN 0352-5139 Institutional research plan: CEZ:AV0Z40550506 Keywords : curcumin * antioxidant * UV-Vis spectrophotometry * DNA complexation * chemiluminescence Subject RIV: CC - Organic Chemistry Impact factor: 0.912, year: 2012

  16. Development of a Direct Spectrophotometric and Chemometric Method for Determining Food Dye Concentrations.

    Science.gov (United States)

    Arroz, Erin; Jordan, Michael; Dumancas, Gerard G

    2017-07-01

    An ultraviolet visible (UV-Vis) spectrophotometric and partial least squares (PLS) chemometric method was developed for the simultaneous determination of erythrosine B (red), Brilliant Blue, and tartrazine (yellow) dyes. A training set (n = 64) was generated using a full factorial design and its accuracy was tested in a test set (n = 13) using a Box-Behnken design. The test set garnered a root mean square error (RMSE) of 1.79 × 10 -7 for blue, 4.59 × 10 -7 for red, and 1.13 × 10 -6 for yellow dyes. The relatively small RMSE suggests only a small difference between predicted versus measured concentrations, demonstrating the accuracy of our model. The relative error of prediction (REP) for the test set were 11.73%, 19.52%, 19.38%, for blue, red, and yellow dyes, respectively. A comparable overlay between the actual candy samples and their replicated synthetic spectra were also obtained indicating the model as a potentially accurate method for determining concentrations of dyes in food samples.

  17. Spectrophotometric and spectrofluorimetric methods for determination of certain biologically active phenolic drugs in their bulk powders and different pharmaceutical formulations

    Science.gov (United States)

    Omar, Mahmoud A.; Badr El-Din, Kalid M.; Salem, Hesham; Abdelmageed, Osama H.

    2018-03-01

    Two simple and sensitive spectrophotometric and spectrofluorimetric methods for the determination of terbutaline sulfate, fenoterol hydrobromide, etilefrine hydrochloride, isoxsuprine hydrochloride, ethamsylate, doxycycline hyclate have been developed. Both methods were based on the oxidation of the cited drugs with cerium (IV) in acid medium. The spectrophotometric method was based on measurement of the absorbance difference (ΔA), which represents the excess cerium (IV), at 317 nm for each drug. On the other hand, the spectrofluorimetric method was based on measurement of the fluorescent of the produced cerium (III) at emission wavelength 354 nm (λexcitation = 255 nm) for the concentrations studied for each drug. For both methods, the variables affecting the reactions were carefully investigated and the conditions were optimized. Linear relationships were found between either ΔA or the fluorescent of the produced cerium (III) values and the concentration of the studied drugs in a general concentration range of 2.0-24.0 μg mL- 1, 20.0-24.0 ng mL- 1 with good correlation coefficients in the following range 0.9990-0.9999, 0.9990-0.9993 for spectrophotometric and spectrofluorimetric methods respectively. The limits of detection and quantitation of spectrophotometric method were found in general concentration range 0.190-0.787 and 0.634-2.624 μg mL- 1respectively. For spectrofluorimetric method, the limits of detection and quantitation were found in general concentration range 4.77-9.52 and 15.91-31.74 ng mL- 1 respectively. The stoichiometry of the reaction was determined, and the reactions pathways were postulated. The analytical performance of the methods, in terms of accuracy and precision, were statistically validated and the results obtained were satisfactory. The methods have been successfully applied to the determination of the cited drugs in their commercial pharmaceutical formulations. Statistical comparison of the results with the reference methods

  18. Preparation, Characterization, and UV Irradiation of Mars Soil Analogues Under Simulated Martian Conditions to Support Detection of Molecular Biomarkers

    Science.gov (United States)

    Fornaro, T.; Brucato, J. R.; ten Kate, I. L.; Siljeström, S.; Steele, A.; Cody, G. D.; Hazen, R. M.

    2018-04-01

    We present laboratory activities of preparation, characterization, and UV irradiation processing of Mars soil analogues, which are key to support both in situ exploration and sample return missions devoted to detection of molecular biomarkers on Mars.

  19. AN APPLICATION OF FLOW INJECTION ANALYSIS WITH GAS DIFFUSION AND SPECTROPHOTOMETRIC DETECTION FOR THE MONITORING OF DISSOLVED SULPHIDE CONCENTRATION IN ENVIRONMENTAL SAMPLES

    Directory of Open Access Journals (Sweden)

    Malwina Cykowska

    2014-10-01

    Full Text Available The monitoring of the concentration of sulphide is very important from the environment point of view because of high toxicity of hydrogen sulphide. What is more hydrogen sulphide is an important pollution indicator. In many cases the determination of sulphide is very difficult due to complicated matrix of some environmental samples, which causes that most analytical methods cannot be used. Flow injection analysis allows to avoid matrix problem what makes it suitable for a wide range of applications in analytical laboratories. In this paper determination of dissolved sulphide in environmental samples by gas-diffusion flow injection analysis with spectrophotometric detection was presented. Used gas-diffusion separation ensures the elimination of interferences caused by sample matrix and gives the ability of determination of sulphides in coloured and turbid samples. Studies to optimize the measurement conditions and to determine the value of the validation parameters (e.g. limit of detection, limit of quantification, precision, accuracy were carried out. Obtained results confirm the usefulness of the method for monitoring the concentration of dissolved sulphides in water and waste water. Full automation and work in a closed system greatly reduces time of analysis, minimizes consumption of sample and reagents and increases safety of analyst’s work.

  20. DLLME-spectrophotometric determination of glyphosate residue in legumes.

    Science.gov (United States)

    Çetin, Emine; Şahan, Serkan; Ülgen, Ahmet; Şahin, Uğur

    2017-09-01

    A new separation and pre-concentration method for spectrophotometric determination of glyphosate herbicide was developed. Glyphosate was converted into dithiocarbamic acid with CS 2 , followed by copper in the presence of ammonia to promote complex formation. This complex was collected in a CH 2 Cl 2 organic drop and absorbance measured at 435nm. The analytical parameters, such as the amount of NH 3 , Cu(II) and CS 2 , type of extraction solutions, and the ratio of dispersive and organic liquids were optimized. The calibration curve was linear in the range 0.5-10mgl -1 . The limits of detection and quantification were calculated from 3s to 10s criterions as 0.21mgl -1 and 0.70mgl -1 , respectively. The developed method was applied to legume samples with the satisfactory recovery values of 98±4-102±3%. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. New potentiometric and spectrophotometric methods for the determination of dextromethorphan in pharmaceutical preparations.

    Science.gov (United States)

    Elmosallamy, Mohamed A F; Amin, Alaa S

    2014-01-01

    New, simple and convenient potentiometric and spectrophotometric methods are described for the determination of dextromethorphan hydrobromide (DXM) in pharmaceutical preparations. The potentiometric technique is based on developing a potentiometric sensor incorporating the dextromethorphan tetrakis(p-chlorophenyl)borate ion-pair complex as an electroactive species in a plasticized PVC matrix membrane with o-nitophenyl octyl ether or dioctyl phthalate. The sensor shows a rapid near Nernstian response of over 1 × 10(-5) - 1 × 10(-2) mol L(-1) dextromethorphan in the pH range of 3.0 - 9.0. The detection limit is 2 × 10(-6) mol L(-1) DXM and the response time is instantaneous (2 s). The proposed spectrophotometric technique involves the reaction of DXM with eriochrom black T (EBT) to form an ion-associate complex. Solvent extraction is used to improve the selectivity of the method. The optimal extraction and reaction conditions have been studied, and the analytical characteristics of the method have been obtained. Linearity is obeyed in the range of 7.37 - 73.7 × 10(-5) mol L(-1) DXM, and the detection limit of the method is 1.29 × 10(-5) mol L(-1). The relative standard deviation (RSD) and relative error for six replicate measurements of 3.685 × 10(-4) mol L(-1) are 0.672 and 0.855%, respectively. The interference effect of some excepients has also been tested. The drug contents in pharmaceutical preparations were successfully determined by the proposed methods by applying the standard-addition technique.

  2. APPLICATION OF UV-SPECTROPHOTOMETRY FOR THE QUANTITATIVE DETERMINATION OF CAPTOPRIL IN DRUG

    Directory of Open Access Journals (Sweden)

    Yu. V. Monaykina

    2015-04-01

    Full Text Available Introduction. In this paper the simple, rapid and sensitive assay method for the quantitative determination of captopril in two new pharmaceutical formulations (suppositories and nasal gel is proposed. Analysis was performed directly by using zero-order UV spectrophotometry. It is known from the special literature that the chromatographic techniques used for captopril assay require the expensive equipment and are rather time consuming. Therefore UV spectrophotometry is preferable due to its accuracy, sensitivity and simplicity. The aim of this study was to develop and validate a new, simple, rapid, precise and accurate UV spectrophotometric method for the quantitative determination of captopril in suppositories and nasal gel. Materials and methods. The objects of the study were the new drug formulations of captopril, namely 0,05 suppositories and 2,5% nasal gel developed by the scientists of The Chair of Technology of Drugs ofZaporozhye State Medical University. Distilled water was used as the solvent, working standard sample of captopril was used as a reference standard. Analytical equipment: spectrophotometer Specord 200, electronic balance ABT-120-5DM, measuring glassware of class A. Assay procedure: An accurately weighed sample of gel (0,4000 –0,8000 g or one suppository was dissolved in distilled water and filtered into a volumetric flask (50,00 ml for gel and 250,0 ml for suppository . Then the solution was brought to the mark with the same solvent and stirred. 1,00 ml of the resulting solution was transferred into a 25,00 ml volumetric flask and brought to the mark with distilled water. Absorbance was measured at a wavelength of 203 nm on the blank of a solvent. The parallel measurement with 1,00 ml of 0,03% captopril standard solution was carried out. The content of active substance was calculated according to standard formulas. Results. The suggested procedure was successfully applied for the analysis of two new pharmaceutical

  3. Spectrophotometric Determination of Nitrate in Vegetables Using ...

    African Journals Online (AJOL)

    DR. MIKE HORSFALL

    ABSTRACT: A rapid and sensitive spectrophotometric method for the determination of nitrate in vegetables is described. The method is based on the measurement of the absorbance of yellow sodium nitrophenoxide formed via the reaction of phenol with the vegetable-based nitrate in presence of sulphuric acid.

  4. Spectrophotometric Methods for the Determination of Ketoconazole ...

    African Journals Online (AJOL)

    Spectrophotometric Methods for the Determination of Ketoconazole in Pharmaceutical Dosage Forms. ... Tropical Journal of Pharmaceutical Research ... Methods: The first method (A) was based on the oxidation of the studied drug by a known excess of cerium (IV) as an oxidizing agent and subsequent determination of ...

  5. Spectrophotometric Determination of Trimipramine in Tablet Dosage ...

    African Journals Online (AJOL)

    Purpose: To develop and validate simple, rapid and sensitive spectrophotometric procedures for determination of trimipramine in tablet dosage form. Methods: The methods were based on the interaction of trimipramine as n-electron donor with the ο-acceptor, iodine and various π-acceptors, namely: chloranil (CH), ...

  6. Spectrophotometric determination of trace and ultratrace levels of boron in silicon and chlorosilane samples

    International Nuclear Information System (INIS)

    Chen, J.S.; Lin, H.M.; Yang, M.H.

    1991-01-01

    Spectrophotometric methods for the determination of boron in the low μg/g and ng/g range in high-purity silicon and dichloro- and trichlorosilanes were investigated in detail. The procedures established involve dissolution of silicon samples and the hydrolyzed products of chlorosilane samples in hydrofluoric acid-containing reagents followed by evaporation of the silicon matrix as H 2 SiF 6 . The boron retained in the treated sample solution was then determined by a spectrophotometric method using carminic acid as a chromatic reagent. Special effort has been paid to the control of the analytical blank and reproducible determination of boron. The results indicate that addition of mannitol and proper control of the evaporation process are effective in preventing volatilization of boron during the evaporation of silicon matrix and can thus attain high recovery of boron and reproducible analysis. Through meticulous control of the analytical blank and experimental conditions, the limit of detection for boron determination with the established method can be as low as ng/g levels. Application of the methods to the determination of boron in various stages of purification of silicon and trichlorosilane as well as in borophosphosilicate film was conducted. (orig.)

  7. Spectrophotometric Determination of Doxycycline Hyclate in Pure and Capsule using Diazotization Reaction

    Directory of Open Access Journals (Sweden)

    Ruba Fahmi Abbas

    2017-07-01

    Full Text Available A sensitive spectrophotometric method has been developed for the determination of Doxycycline hyclate (DCH as pure and  capsule forms. This method is based on diazotization of primary amine group of benzocaine with sodium nitrite in hydrochloric acid medium; the formed diazonium salt is then reacted with DCH in sodium hydroxide medium, to form yellow – orange Azo dye. Beer's law is obeyed in the concentration rang 16-34mg. ml-1 at 480 nm with detection limit LOD and molar absorptivity Є were found to be 0.418 mg.ml-1 and 2.214× 10+4 L.mol-1.cm-1, respectively.

  8. Quantifying tropical peatland dissolved organic carbon (DOC) using UV-visible spectroscopy.

    Science.gov (United States)

    Cook, Sarah; Peacock, Mike; Evans, Chris D; Page, Susan E; Whelan, Mick J; Gauci, Vincent; Kho, Lip Khoon

    2017-05-15

    UV-visible spectroscopy has been shown to be a useful technique for determining dissolved organic carbon (DOC) concentrations. However, at present we are unaware of any studies in the literature that have investigated the suitability of this approach for tropical DOC water samples from any tropical peatlands, although some work has been performed in other tropical environments. We used water samples from two oil palm estates in Sarawak, Malaysia to: i) investigate the suitability of both single and two-wavelength proxies for tropical DOC determination; ii) develop a calibration dataset and set of parameters to calculate DOC concentrations indirectly; iii) provide tropical researchers with guidance on the best spectrophotometric approaches to use in future analyses of DOC. Both single and two-wavelength model approaches performed well with no one model significantly outperforming the other. The predictive ability of the models suggests that UV-visible spectroscopy is both a viable and low cost method for rapidly analyzing DOC in water samples immediately post-collection, which can be important when working at remote field sites with access to only basic laboratory facilities. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. A spectrophotometric study of cerium IV and chromium VI species in nuclear fuel reprocessing process streams

    International Nuclear Information System (INIS)

    Nickson, I D; Boxall, C; Jackson, A; Whillock, G O H

    2010-01-01

    Nuclear fuel reprocessing schemes such as PUREX and UREX utilise HNO 3 media. An understanding of the corrosion of process engineering materials such as stainless steel in such media is a major concern for the nuclear industry. Two key species are cerium and chromium which, as Ce(IV), Cr(VI), may act as corrosion accelerants. An on-line analytical technique for these quantities would be useful for determining the relationship between corrosion rate and [Ce(IV)] and [Cr(VI)]. Consequently, a strategy for simultaneous quantification of Ce(IV), Cr(VI) and Cr(III) in the presence of other ions found in average burn-up Magnox / PWR fuel reprocessing stream (Fe, Mg, Nd, Al) is being developed. This involves simultaneous UV-vis absorbance measurement at 620, 540, 450 nm, wavelengths where Ce and Cr absorb but other ions do not. Mixed solutions of Cr(VI) and Ce(IV) are found to present higher absorbance values at 540 nm than those predicted from absorbances recorded from single component solutions of those ions. This is attributed to the formation of a 3:1 Cr(VI)-Ce(IV) complex and we report on the complexation and UV-visible spectrophotometric characteristics of this species. To the best of our knowledge this is the first experimental study of this complex in aqueous nitric acid solution systems.

  10. SPECTROPHOTOMETRIC DETERMINATION OF ACETYLCYSTEINE IN PHARMACEUTICAL FORMULATIONS USING 2,3-DICHLORO-1,4-NAPTHOQUINONE

    Directory of Open Access Journals (Sweden)

    A. O. Donchenko

    2015-04-01

    Full Text Available The aim of research was the development and validation ofspectrophotometric method foracetylcysteine assay in pharmaceutical formulations.Тhe proposed method is based on the reaction with 2,3-dichloro-1,4-naphthoquinone and the formation of colored products that exhibit absorption maxima at 425 nm. Introduction Many analytical methods have been published for acetylcysteine assay in pharmaceutical formulations as high-performance liquid chromatography (HPLC, fluorimetry and chemiluminescence. Some of these methods are time consuming or require expensive equipment. Other published methods suffer from lack of selectivity and sensitivity. Spectrophotometry is the most widely used technique in pharmaceutical analysis because it is simple, economic, and easily available to most quality control laboratories. In the present work, we propose a simple and accurate spectrophotometric method for acetylcysteine assay in pharmaceutical formulations. Materials and Methods Reagents: Reference standard acetylcysteinesubstance; 2,3-dichloro-1,4-naphthoquinone. All chemicals and solvents were of analytical grade. DMFA was used as a solvent. Pharmaceutical preparations:powder for oral solution «ACC 200» 200 mgseries number50026151 (Salutas Pharma CmbH, Germany; effervescent tablets «Fluimucil» 600 mg (Zambon S.P.A., Italy and «ACC LONG» 600 mg (Salutas Pharma CmbH, Germany series numbers 321284 and DH2740; solution for injections «Fluimucil» 100 mg/ml (Zambon S.P.A., Italyseries number28002492. Solutions: Acetylcysteine stock solution (0,16%; DMFAsolution of 2,3-dichloro-1,4-naphthoquinone (4%. Equipment Analytical balance (ABT-120-5DM; UV-VIS spectrophotometer (Specord 200; water bath (MemmertWNB 7-45;quartz cells. Results Acetylcysteine was determined using a spectrophotometric method based on the reaction with 2,3-dichloro-1,4-naphthoquinone to form yellow colored reaction products with absorption maxima at 425 nm. The effect of reaction time and

  11. Photostabilization of butyl methoxydibenzoylmethane (Avobenzone) and ethylhexyl methoxycinnamate by bis-ethylhexyloxyphenol methoxyphenyl triazine (Tinosorb S), a new UV broadband filter.

    Science.gov (United States)

    Chatelain, E; Gabard, B

    2001-09-01

    It is now well documented that chronic UVA exposure induces damage to human skin. Therefore, modern sunscreens should not only provide protection from both UVB and UVA radiation but also maintain this protection during the entire period of exposure to the sun. UVA filters, however, are rare and not sufficiently photostable. We investigated the effect of the introduction of a new UV filter, bis-ethylhexyloxyphenol methoxyphenyl triazine (Tinosorb S), in oil in water sunscreen formulations on the photostability of butyl methoxydibenzoylmethane (Avobenzone [AVB]) after irradiation with an optically filtered Xenon arc source (UV irradiance adjusted at 1 mean effective dose [MED]/min). With spectrophotometrical methods to assess the sun protection factor (SPF) and UVA ratio and chromatographical methods to determine the amount of UV filters recovered after irradiation we showed that Tinosorb S prevented the photodegradation of AVB in a concentration-dependent way, leading to a sustained SPF and UVA ratio even after irradiation with doses of up to 30 MED. Since AVB was shown to destabilize ethylhexyl methoxycinnamate (EHM) we tested the effect of Tinosorb S in sunscreens containing this UV filter combination. Here too Tinosorb S showed photoprotective properties toward both UV filters. Thus, Tinosorb S can be used successfully to improve the photostability and efficiency of sunscreens containing AVB and EHM.

  12. Influence of uranyl dibutylphosphate on the UV/VIS spectrophotometric online monitoring of uranium in tributylphosphate/hydrocarbon solvent

    International Nuclear Information System (INIS)

    Creech, E.T.; Rutenberg, A.C.; Smithwick, R.W.; Seals, R.D.

    1984-01-01

    In the uranium recovery process at the Y-12 Plant uranium is recovered from aqueous uranyl solutions by extraction into a solvent consisting of 30% tributylphosphate (TBP) and 70% hydrocarbon solvent. Within this process the uranium is continuously monitored by a UV/VIS absorbance measurement of the uranyl/tributylphosphate complex in the organic phase. The uranium is then further extracted from the organic phase to a final water phase. Dibutylphosphate (DBP), which is a decomposition product of TBP, builds up in the organic solvent. A very strong complex of uranyl/dibutylphosphate is formed which cannot be extracted into the aqueous phase. Prior to this work the uranyl/dibutylphosphate complex absorbance was assumed to be the same as the uranyl tributylphosphate complex. To determine the effect of the presence of uranyl/dibutylphosphate on the continuous UV/VIS monitor required (a) the purification of commercial dibutylphosphate, (b) the synthesis, and (c) the characterization of uranyl/dibutylphosphate

  13. The New World Observer: Scientific rationale for detecting biomarkers between the UV and near infrared

    Science.gov (United States)

    Seager, S.; Wilkinson, E.; Cash, W.

    2003-12-01

    The New World Observer(NWO) is a distributed instrument concept designed for UV/visible wavelength spectroscopy of extrasolar planets and was submitted in response to the NASA "Vision Mission" announcement of opportunity. NWO is essentially a pinhole camera where the "pinhole" and the "detector" are separate, formation flying spacecraft separated by ˜180,000 km. The size of the "pinhole" and distance from the "detector" spacecraft are optimized for isolating the image of an Earth-like planet from it's parent star at the focal plane and minimizing the time necessary to acquire a low-resolution spectrum of the planet. We present the scientific rationale behind observing in the UV/visible/near-IR portion of the electromagnetic spectrum and simulations of potential spectra. We discuss the biomarkers that exist from UV wavelengths through 2 microns, including, but not limited to, water, oxygen, ozone, nitrous oxide, and methane, and possible interpretations that can be derived from detections of these biomarkers. Also discussed are the effects of vegetation, weather, and planetary rotation. Simulations of observed spectra assume different instrument configurations and explore the sensitivity of NWO to a variety of biomarkers. Ultimately, the simulations demonstrate the power of the NWO concept for acquiring high quality spectra of Earth-like planets out to tens of parsecs.

  14. Spectrophotometric and Voltammetric Studies on the Interaction of ...

    African Journals Online (AJOL)

    0.84V(vs. SCE) also changed correspondingly without change of the peak potential, which also indicated that the binding reaction had taken place. Under the selected conditions a new spectrophotometric analytical method was established for ...

  15. 340nm UV LED excitation in time-resolved fluorescence system for europium-based immunoassays detection

    DEFF Research Database (Denmark)

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter

    2017-01-01

    In immunoassay analyzers for in-vitro diagnostics, Xenon flash lamps have been widely used as excitation light sources. Recent advancements in UV LED technology and its advantages over the flash lamps such as smaller footprint, better wall-plug efficiency, narrow emission spectrum......, and no significant afterglow, have made them attractive light sources for gated detection systems. In this paper, we report on the implementation of a 340 nm UV LED based time-resolved fluorescence system based on europium chelate as a fluorescent marker. The system performance was tested with the immunoassay based...... on the cardiac marker, TnI. The same signal-to-noise ratio as for the flash lamp based system was obtained, operating the LED below specified maximum current. The background counts of the system and its main contributors were measured and analyzed. The background of the system of the LED based unit was improved...

  16. Development and Application of Kinetic Spectrophotometric Method ...

    African Journals Online (AJOL)

    Purpose: To develop an improved kinetic-spectrophotometric procedure for the determination of metronidazole (MNZ) in pharmaceutical formulations. Methods: The method is based on oxidation reaction of MNZ by hydrogen peroxide in the presence of Fe(II) ions at pH 4.5 (acetate buffer). The reaction was monitored ...

  17. Titrimetric and Spectrophotometric Determination of Metaprolol tartrate in Pharmaceuticals Using N-Bromosuccinimide

    OpenAIRE

    K. Basavaiah; B. C. Somashekar

    2007-01-01

    One titrimetric and two spectrophotometric methods are presented for the assay of metaprolol tartrate (MPT) in bulk drug and in tablets. The methods employ N-bromosuccinimide (NBS) as the oxidimetric reagent and two dyes, methyl orange and indigo carmine as spectrophotometric reagents. In titrimetry, an acidified solution of MPT is treated with a known excess amount of NBS and after a definite time, the unreacted oxidant is determined by iodometric back titration. Spectrophotometry involve...

  18. Spectrophotometric determination of nitrite by its catalytic effect on the oxidation of congo red with bromate

    Directory of Open Access Journals (Sweden)

    Zenovia Moldovan

    2012-08-01

    Full Text Available A novel simple, sensitive and rapid kinetic-spectrophotometric method for the determination of trace amounts of nitrite is proposed. The method is based on its catalytic effect on the oxidation of congo red (CR by potassium bromate in acidic solution. The oxidation reaction is monitored spectrophotometrically by measuring the decrease in the absorbance of CR at a suitable λmax = 570 nm for the first 10–40 s from the start of the reaction. Under the optimum experimental conditions (sulfuric acid, 0.3 M; CR, 0.75Χ10-4 M; potassium bromate, 5Χ10-4 M and 25 oC, nitrite can be determined in the range of 0.015–0.75 µg mL−1 with the detection limit of 0.006 µg mL−1. The relative standard deviation of five replicate determination of 0.25 µg mL−1 nitrite was 2.5%. The proposed method was applied satisfactorily to the determination of nitrite in spiked drinking water samples.DOI: http://dx.doi.org/10.4314/bcse.v26i2.1

  19. Simultaneous Determination of 14 Phenolic Compounds in Grape Canes by HPLC-DAD-UV Using Wavelength Switching Detection

    Directory of Open Access Journals (Sweden)

    Ang Zhang

    2013-11-01

    Full Text Available The paper described a novel chromatographic method for the simultaneous determination of phenolic compounds such as gallic, protocatechuic, vanillic, caffeic, syringic, p-coumaric and salicylic acid, (+-catechin, (‒-epicatechin, rutin, morin, quercetin, coumarin and trans-resveratrol at their maximum absorbance wavelengths (MAW employing reverse-phase high performance liquid chromatography combined with DAD and UV detection via detection wavelength switching. The method was based on MAW acquisition by DAD and quantification by UV. The separation process was performed on a Shim-Pack VP-ODS C18 column (250 mm × 4.6 mm, 5 μm held at 30 °C, utilizing 3.0% acetic acid and acetonitrile as mobile phase at a flow rate of 0.8 mL/min in the gradient elution mode. The method was fully validated in terms of linearity (r2 > 0.9990, 10‒350 mg/L, precision (both intra-day and inter-day RSD < 4.22%, accuracy (97.31%‒104.66%, specificity, robustness (0.59% < RSD < 2.86%, limit of detection and quantification. The switching method significantly improved the sensitivities of most phenolics studied in comparison with the standard constant wavelength detection (280 nm. The proposed method has been successfully applied to the determination of 14 phenolic compounds in 89 varieties of one-year-old Chinese grape one-year-canes. Grape canes contain many phenolics, especially trans-resveratrol, (‒-epicatechin, and (+-catechin.

  20. Effects of UV radiation on freshwater metazooplankton

    International Nuclear Information System (INIS)

    Tartarotti, B.

    1999-06-01

    There is evidence that fluxes of solar ultraviolet-B radiation (UV-B, 290-320 nm) are increasing over wide parts of the earth's surface due to stratospheric ozone depletion. UV radiation (290-400 nm) can have damaging effects on biomolecules and cell components that are common to most living organisms. The aim of this thesis is to gain a more thorough understanding of the potential impacts of solar radiation on freshwater metazooplankton. To detect UV-vulnerability in zooplankton populations dominating the zooplankton community of two clear-water, high mountain lakes located one in the Austrian Alps and another in the Chilean Andes, the survival of two copepod species was studied. The organisms were exposed to a 10- to 100-fold increase in UV-B radiation compared to those levels found at their natural, maximum daytime distribution. Both species vertically migrate and are pigmented. UV-absorbing compounds with a maximum absorption at ∼334 nm were also detected. Cyclops abyssorum tatricus, a common cyclopoid copepod species of Alpine lakes, was highly resistant to UV-B radiation and no significant lethal effect was observed. The calanoid copepod Boeckella gracilipes, frequent in Andean lakes, had a mortality ∼5 times higher in the treatment receiving full sunlight than in the UV-B excluded treatment (3.2 %) only when exposed for 70 h. The resistance of B. gracilipes was higher than that reported in the literature for the same species suggesting the existence of intraspecific differences in UV sensitivity. Survival, fecundity and development of the zooplankton community of a clear-water, high elevation Andean lake (33 o S) were studied with mesocosms experiments after prolonged UV exposure (48 days). When exposed to full sunlight, the population of the cladoceran Chydorus sphaericus and the rotifer Lepadella ovalis were strongly inhibited by UV-B, whereas both species were resistant to UV-A radiation. Conversely, UV-B radiation had no effect on the survival of the

  1. Detection, fate and inactivation of pathogenic norovirus employing settlement and UV treatment in wastewater treatment facilities

    International Nuclear Information System (INIS)

    Barrett, M.; Fitzhenry, K.; O'Flaherty, V.; Dore, W.; Keaveney, S.; Cormican, M.; Rowan, N.; Clifford, E.

    2016-01-01

    It is accepted that discharged wastewaters can be a significant source of pathogenic viruses in receiving water bodies contributing to pollution and may in turn enter the human food chain and pose a risk to human health, thus norovirus (NoV) is often a predominant cause of gastroenteritis globally. Working with NoV poses particular challenges as it cannot be readily identified and detection by molecular methods does not assess infectivity. It has been proposed that the infectivity of NoV may be modelled through the use of an alternative virus; F-specific RNA (FRNA) bacteriophages; GA genotype and other FRNA bacteriophages have been used as a surrogate in studies of NoV inactivation. This study investigated the efficiency of novel pulsed ultraviolet irradiation and low pressure ultraviolet irradiation as a potential pathogen inactivation system for NoV and FRNA bacteriophage (GA) in secondary treated wastewaters. The role of UV dose and the impact of suspended solids concentration on removal efficiency were also examined. The study also investigated the role of settlement processes in wastewater treatment plants in removing NoV. While NoV inactivation could not be determined it was found that at a maximum UV dose of 6.9 J/cm"2 (6900 mJ/cm"2) an average 2.4 log removal of FRNA bacteriophage (GA) was observed; indicating the potential need for high UV doses to remove NoV if FRNA bacteriophage prove a suitable indicator for NoV. The study found that increasing concentrations of suspended solids impacted on PUV efficiency however, it appears the extent of the impact may be site specific. Furthermore, the study found that settlement processes can play a significant role in the removal of FRNA bacteriophage, thus potentially NoV. - Highlights: • Effectiveness of low pressure UV and novel high-intensity pulsed UV disinfection in NoVs removal. • Reduction of FRNA bacteriophage was seen in clarified wastewater after settling. • Adsorption of viral particles to solids

  2. Detection, fate and inactivation of pathogenic norovirus employing settlement and UV treatment in wastewater treatment facilities

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, M. [Microbial Ecology Laboratory, Microbiology, School of Natural sciences, National University of Ireland Galway (Ireland); Ryan Institute, National University of Ireland Galway (Ireland); College of Engineering and Informatics, National University of Ireland Galway (Ireland); Fitzhenry, K. [Ryan Institute, National University of Ireland Galway (Ireland); College of Engineering and Informatics, National University of Ireland Galway (Ireland); O' Flaherty, V. [Microbial Ecology Laboratory, Microbiology, School of Natural sciences, National University of Ireland Galway (Ireland); Ryan Institute, National University of Ireland Galway (Ireland); Dore, W.; Keaveney, S. [Marine Institute, Galway (Ireland); Cormican, M. [Ryan Institute, National University of Ireland Galway (Ireland); Centre for Health from Environment, Ryan Institute, National University of Ireland Galway (Ireland); Rowan, N. [Bioscience Research Institute, Athlone Institute of Technology (Ireland); Clifford, E., E-mail: eoghan.clifford@nuigalway.ie [Ryan Institute, National University of Ireland Galway (Ireland); College of Engineering and Informatics, National University of Ireland Galway (Ireland)

    2016-10-15

    It is accepted that discharged wastewaters can be a significant source of pathogenic viruses in receiving water bodies contributing to pollution and may in turn enter the human food chain and pose a risk to human health, thus norovirus (NoV) is often a predominant cause of gastroenteritis globally. Working with NoV poses particular challenges as it cannot be readily identified and detection by molecular methods does not assess infectivity. It has been proposed that the infectivity of NoV may be modelled through the use of an alternative virus; F-specific RNA (FRNA) bacteriophages; GA genotype and other FRNA bacteriophages have been used as a surrogate in studies of NoV inactivation. This study investigated the efficiency of novel pulsed ultraviolet irradiation and low pressure ultraviolet irradiation as a potential pathogen inactivation system for NoV and FRNA bacteriophage (GA) in secondary treated wastewaters. The role of UV dose and the impact of suspended solids concentration on removal efficiency were also examined. The study also investigated the role of settlement processes in wastewater treatment plants in removing NoV. While NoV inactivation could not be determined it was found that at a maximum UV dose of 6.9 J/cm{sup 2} (6900 mJ/cm{sup 2}) an average 2.4 log removal of FRNA bacteriophage (GA) was observed; indicating the potential need for high UV doses to remove NoV if FRNA bacteriophage prove a suitable indicator for NoV. The study found that increasing concentrations of suspended solids impacted on PUV efficiency however, it appears the extent of the impact may be site specific. Furthermore, the study found that settlement processes can play a significant role in the removal of FRNA bacteriophage, thus potentially NoV. - Highlights: • Effectiveness of low pressure UV and novel high-intensity pulsed UV disinfection in NoVs removal. • Reduction of FRNA bacteriophage was seen in clarified wastewater after settling. • Adsorption of viral particles

  3. Determination of lisinopril in pharmaceuticals by a kinetic spectrophotometric method

    Directory of Open Access Journals (Sweden)

    Čakar Mira

    2012-01-01

    Full Text Available A kinetic spectrophotometric method for determination of lisinopril in pharmaceuticals has been developed. The method is based on activator action of lisinopril on Cu(II ions catalysing the oxidation of nile blue A with hydrogen peroxide in borate buffer (pH 9.3. A decrease of the absorbance was recorded at 635 nm for 5 min at 25°C. The linearity was established applying the tangent method within the concentration range of lisinopril from 0.8-6.4 μg mL-1, the detection and quantification limits being 0.158 μg mL-1 and 0.480 μg mL-1, respectively. The method has been successfully applied in three brands of tablets containing lisinopril alone or in combination with hydrochlorothiazide.

  4. Simultaneous quantitative determination of paracetamol and tramadol in tablet formulation using UV spectrophotometry and chemometric methods

    Science.gov (United States)

    Glavanović, Siniša; Glavanović, Marija; Tomišić, Vladislav

    2016-03-01

    The UV spectrophotometric methods for simultaneous quantitative determination of paracetamol and tramadol in paracetamol-tramadol tablets were developed. The spectrophotometric data obtained were processed by means of partial least squares (PLS) and genetic algorithm coupled with PLS (GA-PLS) methods in order to determine the content of active substances in the tablets. The results gained by chemometric processing of the spectroscopic data were statistically compared with those obtained by means of validated ultra-high performance liquid chromatographic (UHPLC) method. The accuracy and precision of data obtained by the developed chemometric models were verified by analysing the synthetic mixture of drugs, and by calculating recovery as well as relative standard error (RSE). A statistically good agreement was found between the amounts of paracetamol determined using PLS and GA-PLS algorithms, and that obtained by UHPLC analysis, whereas for tramadol GA-PLS results were proven to be more reliable compared to those of PLS. The simplest and the most accurate and precise models were constructed by using the PLS method for paracetamol (mean recovery 99.5%, RSE 0.89%) and the GA-PLS method for tramadol (mean recovery 99.4%, RSE 1.69%).

  5. Sensitive flow-injection spectrophotometric analysis of bromopride

    Science.gov (United States)

    Lima, Liliane Spazzapam; Weinert, Patrícia Los; Pezza, Leonardo; Pezza, Helena Redigolo

    2014-12-01

    A flow injection spectrophotometric procedure employing merging zones is proposed for direct bromopride determination in pharmaceutical formulations and biological fluids. The proposed method is based on the reaction between bromopride and p-dimethylaminocinnamaldehyde (p-DAC) in acid medium, in the presence of sodium dodecyl sulfate (SDS), resulting in formation of a violet product (λmax = 565 nm). Experimental design methodologies were used to optimize the experimental conditions. The Beer-Lambert law was obeyed in a bromopride concentration range of 3.63 × 10-7 to 2.90 × 10-5 mol L-1, with a correlation coefficient (r) of 0.9999. The limits of detection and quantification were 1.07 × 10-7 and 3.57 × 10-7 mol L-1, respectively. The proposed method was successfully applied to the determination of bromopride in pharmaceuticals and human urine, and recoveries of the drug from these media were in the ranges 99.6-101.2% and 98.6-102.1%, respectively. This new flow injection procedure does not require any sample pretreatment steps.

  6. Rapid and direct spectrophotometric method for kinetics studies and routine assay of peroxidase based on aniline diazo substrates.

    Science.gov (United States)

    Mirazizi, Fatemeh; Bahrami, Azita; Haghbeen, Kamahldin; Shahbani Zahiri, Hossein; Bakavoli, Mehdi; Legge, Raymond L

    2016-12-01

    Peroxidases are ubiquitous enzymes that play an important role in living organisms. Current spectrophotometrically based peroxidase assay methods are based on the production of chromophoric substances at the end of the enzymatic reaction. The ambiguity regarding the formation and identity of the final chromophoric product and its possible reactions with other molecules have raised concerns about the accuracy of these methods. This can be of serious concern in inhibition studies. A novel spectrophotometric assay for peroxidase, based on direct measurement of a soluble aniline diazo substrate, is introduced. In addition to the routine assays, this method can be used in comprehensive kinetics studies. 4-[(4-Sulfophenyl)azo]aniline (λmax = 390 nm, ɛ = 32 880 M(-1) cm(-1) at pH 4.5 to 9) was introduced for routine assay of peroxidase. This compound is commercially available and is indexed as a food dye. Using this method, a detection limit of 0.05 nmol mL(-1) was achieved for peroxidase.

  7. Titanium Analysis of Ilmenite Bangka by Spectrophotometric Method Using Perhidrol

    International Nuclear Information System (INIS)

    Rusydi-S

    2004-01-01

    Determination of titanium by spectrofotometric method using perhydrol has been done. The purpose of experiment is to find out the condition of titanium analysis of ilmenite by spectrophotometric method. The experiment parameter e c. analysis condition include the Ti-perhydrol complex spectrum, acidity of complex, perhydrol concentration, linearity, influence of anion, limit detection, interfere elements, application of the method using 40 SRM Standard and analysis for ilmenite samples. Result of experiments are spectrum of Ti-perhydrol complex at 410 nm, acidity of complex is the H 2 SO 4 2 M, perhydrol concentration is 0,24 %, the curve calibration is linier at 1-80 ppm, anion of PO 4 , NO 3 , Cl, CO 3 not be influence until 2000 ppm, limit detection is 0,30 ppm and Mo, V is interfere. The method which was aplicated to 40 SRM standard, shown that the content of Ti is 1580 ppm while the standard is 1600 ppm, and the content of Ti from ilmenite high grade samples is 31,46 % and low grade is 13,55 %. (author)

  8. UV SPECTROPHOTOMETRY APPLICATION FOR QUANTITATIVE DETERMINATION OF VINPOCETINE IN DRUG FORMULATIONS

    Directory of Open Access Journals (Sweden)

    J. V. Monaykina

    2014-12-01

    Full Text Available Introduction. In this paper simple, rapid and sensitive assay methods for quantitative determination of vinpocetine in two new drug formulations (suppositories and nasal cream are proposed. Analysis has been performed directly by using zero-order UV spectrophotometry. It is known from the special literature that the chromatographic techniques used for vinpocetine assay require expensive equipment and are rather time consuming. Therefore UV spectrophotometry is preferable due to its accuracy and simplicity. The object of this study was to develop new, simple, rapid, precise and accurate UV spectrophotometric procedure for the quantitative determination of vinpocetine in suppositories and nasal cream and evaluation of some validation characteristics of the methods. Materials and methods. The objects of the study were the new drug formulations of vinpocetine, namely 0,01 suppositories and 0,5% nasal cream developed by the scientists of The Chair of Technology of Drugs of Zaporizhzhia State Medical University. Distilled water and 0.05M HCl were used as the solvents, working standard sample of vinpocetine was used as a reference standard. Analytical equipment: spectrophotometer Specord 200, electronic balance ABT-120-5DM, measuring glassware of class A. Assay procedure: An accurately weighed sample of cream (1,200 – 2,000 g or one suppository was dissolved in 0.05M HCl and filtered into a 50,00 ml volumetric flask. Then the solution was brought to the mark with the same solvent and stirred. 3,00 ml or 4,00 ml of the resulting solutions (for suppositories or cream respectively were transferred into a 25,00 ml volumetric flask and brought to the mark with distilled water. Absorbance was measured at a wavelength of 272 nm on the blank of distilled water. The parallel measurement with 1,00 ml of 0,064% vinpocetine standard solution was carried out. The content of active substance was calculated according to standard formulas. Results. The suggested

  9. Development of a flow method for the determination of phosphate in estuarine and freshwaters-Comparison of flow cells in spectrophotometric sequential injection analysis

    International Nuclear Information System (INIS)

    Mesquita, Raquel B.R.; Ferreira, M. Teresa S.O.B.; Toth, Ildiko V.; Bordalo, Adriano A.; McKelvie, Ian D.; Rangel, Antonio O.S.S.

    2011-01-01

    Highlights: → Sequential injection determination of phosphate in estuarine and freshwaters. → Alternative spectrophotometric flow cells are compared. → Minimization of schlieren effect was assessed. → Proposed method can cope with wide salinity ranges. → Multi-reflective cell shows clear advantages. - Abstract: A sequential injection system with dual analytical line was developed and applied in the comparison of two different detection systems viz; a conventional spectrophotometer with a commercial flow cell, and a multi-reflective flow cell coupled with a photometric detector under the same experimental conditions. The study was based on the spectrophotometric determination of phosphate using the molybdenum-blue chemistry. The two alternative flow cells were compared in terms of their response to variation of sample salinity, susceptibility to interferences and to refractive index changes. The developed method was applied to the determination of phosphate in natural waters (estuarine, river, well and ground waters). The achieved detection limit (0.007 μM PO 4 3- ) is consistent with the requirement of the target water samples, and a wide quantification range (0.024-9.5 μM) was achieved using both detection systems.

  10. Development of a flow method for the determination of phosphate in estuarine and freshwaters-Comparison of flow cells in spectrophotometric sequential injection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mesquita, Raquel B.R. [CBQF/Escola Superior de Biotecnologia, Universidade Catolica Portuguesa, R. Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal); Laboratory of Hydrobiology, Institute of Biomedical Sciences Abel Salazar (ICBAS) and Institute of Marine Research (CIIMAR), Universidade do Porto, Lg. Abel Salazar 2, 4099-003 Porto (Portugal); Ferreira, M. Teresa S.O.B. [CBQF/Escola Superior de Biotecnologia, Universidade Catolica Portuguesa, R. Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal); Toth, Ildiko V. [REQUIMTE, Departamento de Quimica, Faculdade de Farmacia, Universidade de Porto, Rua Anibal Cunha, 164, 4050-047 Porto (Portugal); Bordalo, Adriano A. [Laboratory of Hydrobiology, Institute of Biomedical Sciences Abel Salazar (ICBAS) and Institute of Marine Research (CIIMAR), Universidade do Porto, Lg. Abel Salazar 2, 4099-003 Porto (Portugal); McKelvie, Ian D. [School of Chemistry, University of Melbourne, Victoria 3010 (Australia); Rangel, Antonio O.S.S., E-mail: aorangel@esb.ucp.pt [CBQF/Escola Superior de Biotecnologia, Universidade Catolica Portuguesa, R. Dr. Antonio Bernardino de Almeida, 4200-072 Porto (Portugal)

    2011-09-02

    Highlights: {yields} Sequential injection determination of phosphate in estuarine and freshwaters. {yields} Alternative spectrophotometric flow cells are compared. {yields} Minimization of schlieren effect was assessed. {yields} Proposed method can cope with wide salinity ranges. {yields} Multi-reflective cell shows clear advantages. - Abstract: A sequential injection system with dual analytical line was developed and applied in the comparison of two different detection systems viz; a conventional spectrophotometer with a commercial flow cell, and a multi-reflective flow cell coupled with a photometric detector under the same experimental conditions. The study was based on the spectrophotometric determination of phosphate using the molybdenum-blue chemistry. The two alternative flow cells were compared in terms of their response to variation of sample salinity, susceptibility to interferences and to refractive index changes. The developed method was applied to the determination of phosphate in natural waters (estuarine, river, well and ground waters). The achieved detection limit (0.007 {mu}M PO{sub 4}{sup 3-}) is consistent with the requirement of the target water samples, and a wide quantification range (0.024-9.5 {mu}M) was achieved using both detection systems.

  11. Highly sensitive spectrophotometric kinetic determination of vanadium by catalysis of the gallic acid-bromate reaction

    International Nuclear Information System (INIS)

    Fukasawa, Tsutomu; Kawakubo, Susumu; Yamanouchi, Tatsuo

    1985-01-01

    Conditions are described for improving the speed and sensitivity of this catalytic determination of vanadium. The reaction of 0.018 M gallic acid with 0.96 M sodium bromate at pH 3.8 and double-beam spectrophotometric measurement at 380 nm are recommended. The highest practical sensitivity at 22-30 0 C was ca. 40 pg for an absorbance change of 0.0005, 50 times better than previously. The detection limit was ca. 0.5 ng of vanadium. Reaction at 50 0 C gave even better sensitivity. (Auth.)

  12. Spectrophotometric Quantification of Flavonoids in Herbal Material, Crude Extract, and Fractions from Leaves of Eugenia uniflora Linn.

    Science.gov (United States)

    Ramos, Rhayanne T M; Bezerra, Isabelle C F; Ferreira, Magda R A; Soares, Luiz Alberto Lira

    2017-01-01

    The traditional use of Eugenia uniflora L. ("Pitanga") is reported due to several properties, which have often been related to its flavonoid content. The aim was to evaluate analytical procedures for quantification of total flavonoids content (TFCs) by ultraviolet-visible (UV-Vis) spectrophotometry in the herbal material (HM), crude extract (CE), and fractions from leaves of E. uniflora . The method for quantification of flavonoids after complexation with aluminum chloride (AlCl 3 ) was evaluated: amount of sample (0.25-1.5 g); solvent (40%-80% ethanol); reaction time and AlCl 3 concentration (2.5%-7.5%). The procedures by direct dilution (DD) and after acid hydrolysis (AH) were used and validated for HM and CE and applied to the aqueous fraction (AqF), hexane fraction, and ethyl acetate fractions (EAF). The ideal conditions of analysis were ethanol 80% as solvent; 0.5 g of sample; λmax of 408 (DD) and 425 nm (AH); 25 min after addition of AlCl 3 5%. The procedures validated for standards and samples showed linearity ( R 2 > 0.99) with limit of detection and limit of quantification between 0.01 and 0.17 mg/mL (rutin and quercetin); and 0.03 and 0.09 mg/mL (quercetin), for DD and AH, respectively. The procedures were accurate (detect, practice, and repair 90%), and stable under robustness conditions (luminosity, storage, reagents, and equipment). The TFCs in AqF and EAF were 0.65 g% and 17.72 g%, calculated as rutin. UV-Vis methods for quantification of TFC in HM, CE, and fractions from leaves of E. uniflora were suitably validated. Regarding the analysis of fractions, the EAF achieved enrichment of about nine times in the content of flavonoids. The total flavonoids content (TFCs) of herbal material, crude extract, and fractions from Eugenia uniflora can be quantified by ultraviolet-visibleThe spectrophotometric methods (direct dilution and acid hydrolysis) were reproducible and able to quantify TFC in raw material and derivatives from leaves of E. uniflora Higher

  13. Self-assembly of nitrogen-doped carbon nanoparticles: a new ratiometric UV-vis optical sensor for the highly sensitive and selective detection of Hg(2+) in aqueous solution.

    Science.gov (United States)

    Ruan, Yudi; Wu, Lie; Jiang, Xiue

    2016-05-23

    Water-soluble nitrogen-doped carbon nanoparticles (N-CNPs) prepared by the one-step hydrothermal treatment of uric acid were found to show ratiometric changes in their UV-vis spectra due to Hg(2+)-mediated self-assembly. For the first time, such a property was developed into a UV-vis optical sensor for detecting Hg(2+) in aqueous solutions with high sensitively and selectively (detection limit = 1.4 nM). More importantly, this novel sensor exhibits a higher linear sensitivity over a wider concentration range compared with the fluorescence sensor based on the same N-CNPs. This work opens an exciting new avenue to explore the use of carbon nanoparticles in constructing UV-vis optical sensors for the detection of metal ions and the use of carbon nanoparticles as a new building block to self-assemble into superlattices.

  14. Spectrophotometric determination of copper with ascorbic acid

    International Nuclear Information System (INIS)

    Majeed, A.; Mustafa, M.M.; Asma, R.N.; Sareecha, N.

    1996-01-01

    Copper has been determined spectrophotometrically by using ascorbic acid as a chromagenic reagent. The complex formed in basic medium is measured for its absorbance at 340 n.m. Interference for 23 cations and 9 anions has also been checked. Effect of pH, time, temperature, ammonia, reagent concentration and interferents has been report. (author)

  15. Spectrophotometric determination of copper with ascorbic acid

    Energy Technology Data Exchange (ETDEWEB)

    Majeed, A; Mustafa, M M; Asma, R N; Sareecha, N [Islamia Univ., Bahawalpur (Pakistan). Chemistry Dept.

    1996-06-01

    Copper has been determined spectrophotometrically by using ascorbic acid as a chromagenic reagent. The complex formed in basic medium is measured for its absorbance at 340 n.m. Interference for 23 cations and 9 anions has also been checked. Effect of pH, time, temperature, ammonia, reagent concentration and interferents has been report. (author).

  16. Investigation of the use of FXG gel dosimeter for UV radiation detection

    International Nuclear Information System (INIS)

    Bero, M.; Abu Kassem, I.

    2009-02-01

    The radio-chromic chemical radiation dosimeter is well known type of detectors that have been used in the measurement application of radiation dose resulting for ionizing radiation such as γ and X-rays. The detector materials consist of mainly water with added gelatin powder that gives the detector its solid shape. Other chemicals sensitive to radiation are also added to form the Ferrous-sulfate Xylenol-orange Gelatin gel detector (FXG). Ionizing radiation effects appears as an increase in the optical absorbance within a defined range of wavelengths located in the visible region of the light spectrum. These visible changes in the materials optical characteristic as a result of radiation exposure is proportional to the radiation absorbed dose at certain wave lengths. Ultraviolet radiation was found to produce similar effects in the FXG detector materials; hence we suggested studying the UV effects in details. It is known that UV radiation carry relatively high quantum energies big enough to enhance important chemical and biological reactions in some exposed medium. This study examines the most important properties required for the FXG detector to be used as a UV monitoring system that is capable of measuring the absorbed UV radiation dose. The study also works on finding chemical detector structure that is easy to be used for simulating the UV interactions with human body. It has been shown that the optical absorbance of standard size FXG samples increases linearly with the exposure time to UV radiation produced by a sun simulator source, when the beam is filtered to produces exposure similar to that found in nature. However, the UV effects are also influenced by the applied UV radiation spectrum used for irradiation as well as the thicknesses of the FXG materials.(authors)

  17. 340 nm pulsed UV LED system for europium-based time-resolved fluorescence detection of immunoassays

    OpenAIRE

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Petersen, Paul Michael; Pedersen, Christian

    2016-01-01

    We report on the design, development and investigation of an optical system based on UV light emitting diode (LED) excitation at 340 nm for time-resolved fluorescence detection of immunoassays. The system was tested to measure cardiac marker Troponin I with a concentration of 200 ng/L in immunoassay. The signal-to-noise ratio was comparable to state-of-the-art Xenon flash lamp based unit with equal excitation energy and without overdriving the LED. We performed a comparative study of the flas...

  18. Liquid-liquid microextraction in a multicommuted flow system for direct spectrophotometric determination of iodine value in biodiesel.

    Science.gov (United States)

    Pereira, Andréia C; Rocha, Fábio R P

    2014-06-04

    A flow-based procedure was developed for the direct spectrophotometric determination of the iodine value (IV) in biodiesel. The procedure was based on the microextraction/reaction of unsaturated compounds with triiodide ions in an aqueous medium by inserting the reagent solution between the aliquots of biodiesel without any pretreatment. The interaction occurred through the biodiesel film formed on the inner walls of the hydrophobic tube used as the reactor and at the aqueous/biodiesel interfaces. The spectrophotometric detection was based on the discoloration of the I3(-) reagent in the aqueous phase by using a glass tube coupled to a fiber-optic spectrophotometer as the detection cell. Reference solutions were prepared by dilution of biodiesel samples with previously determined IV in hexane. The analytical response was linear for IV from 13 to 135 g I2/100 g with a detection limit of 5 g I2/100 g. A coefficient of variation of 1.7% (n=10) and a sampling rate of 108 determinations per hour were achieved by consuming 224 μL of the sample and 200 μg of I2 per determination. The slopes of analytical curves obtained with three different biodiesel samples were in agreement (variations in slopes lower than 3.1%), thus indicating an absence of any matrix effects. Results for biodiesel samples from different sources agreed with the volumetric official procedure at the 95% confidence level. The proposed procedure is therefore a simple, fast, and reliable alternative for estimating the iodine value of biodiesel. Copyright © 2014. Published by Elsevier B.V.

  19. Spectrophotometric titrations: Application to the determination of some elements in uranium solutions

    International Nuclear Information System (INIS)

    L'Her, M.

    1967-01-01

    The aim of this work is the application of spectrophotometric titrations to the analysis of uranium-containing solutions. We have been led to examine the general principles involved in these titrations, and we give a brief outline of these principles. In the first part we deal therefore with spectrophotometric titrations from a general point of view, examining their fundamental principle, their practical execution as well as the various possibilities of the method. The advantage of the titration are examined, in particular that of lending itself simultaneous determination of two species. The possibility of applying these spectrophotometric titrations to the analysis of uranium-containing solutions is the subject of the second part of this report: the dosage of a few species in uranium (VI) solutions is described. To this second part is added an experimental appendix consisting of a description of the apparatus, as well as of the operational techniques used for certain titrations, in particular those involving solutions containing uranium. (author) [fr

  20. Using the Transient Response of WO3 Nanoneedles under Pulsed UV Light in the Detection of NH3 and NO2

    Directory of Open Access Journals (Sweden)

    Oriol Gonzalez

    2018-04-01

    Full Text Available Here we report on the use of pulsed UV light for activating the gas sensing response of metal oxides. Under pulsed UV light, the resistance of metal oxides presents a ripple due to light-induced transient adsorption and desorption phenomena. This methodology has been applied to tungsten oxide nanoneedle gas sensors operated either at room temperature or under mild heating (50 °C or 100 °C. It has been found that by analyzing the rate of resistance change caused by pulsed UV light, a fast determination of gas concentration is achieved (ten-fold improvement in response time. The technique is useful for detecting both oxidizing (NO2 and reducing (NH3 gases, even in the presence of different levels of ambient humidity. Room temperature operated sensors under pulsed UV light show good response towards ammonia and nitrogen dioxide at low power consumption levels. Increasing their operating temperature to 50 °C or 100 °C has the effect of further increasing sensitivity.

  1. SHARDS: An Optical Spectro-photometric Survey of Distant Galaxies

    Science.gov (United States)

    Pérez-González, Pablo G.; Cava, Antonio; Barro, Guillermo; Villar, Víctor; Cardiel, Nicolás; Ferreras, Ignacio; Rodríguez-Espinosa, José Miguel; Alonso-Herrero, Almudena; Balcells, Marc; Cenarro, Javier; Cepa, Jordi; Charlot, Stéphane; Cimatti, Andrea; Conselice, Christopher J.; Daddi, Emmanuele; Donley, Jennifer; Elbaz, David; Espino, Néstor; Gallego, Jesús; Gobat, R.; González-Martín, Omaira; Guzmán, Rafael; Hernán-Caballero, Antonio; Muñoz-Tuñón, Casiana; Renzini, Alvio; Rodríguez-Zaurín, Javier; Tresse, Laurence; Trujillo, Ignacio; Zamorano, Jaime

    2013-01-01

    We present the Survey for High-z Absorption Red and Dead Sources (SHARDS), an ESO/GTC Large Program carried out using the OSIRIS instrument on the 10.4 m Gran Telescopio Canarias (GTC). SHARDS is an ultra-deep optical spectro-photometric survey of the GOODS-N field covering 130 arcmin2 at wavelengths between 500 and 950 nm with 24 contiguous medium-band filters (providing a spectral resolution R ~ 50). The data reach an AB magnitude of 26.5 (at least at a 3σ level) with sub-arcsec seeing in all bands. SHARDS' main goal is to obtain accurate physical properties of intermediate- and high-z galaxies using well-sampled optical spectral energy distributions (SEDs) with sufficient spectral resolution to measure absorption and emission features, whose analysis will provide reliable stellar population and active galactic nucleus (AGN) parameters. Among the different populations of high-z galaxies, SHARDS' principal targets are massive quiescent galaxies at z > 1, whose existence is one of the major challenges facing current hierarchical models of galaxy formation. In this paper, we outline the observational strategy and include a detailed discussion of the special reduction and calibration procedures which should be applied to the GTC/OSIRIS data. An assessment of the SHARDS data quality is also performed. We present science demonstration results on the detection and study of emission-line galaxies (star-forming objects and AGNs) at z = 0-5. We also analyze the SEDs for a sample of 27 quiescent massive galaxies with spectroscopic redshifts in the range 1.0 UV-to-MIR SEDs of the massive quiescent galaxies at z = 1.0-1.4 are well described by an exponentially decaying star formation history with scale τ = 100-200 Myr, age around 1.5-2.0 Gyr, solar or slightly sub-solar metallicity, and moderate extinction, A(V) ~ 0.5 mag. We also find that galaxies with masses above M* are typically older than lighter galaxies, as expected in a downsizing scenario of galaxy formation. This

  2. Development and Validation of Spectrophotometric Methods for the Determination of Rasagiline in Pharmaceutical Preparations

    Directory of Open Access Journals (Sweden)

    Serife Evrim Kepekci Tekkeli

    2013-01-01

    Full Text Available This study presents three simple, rapid, and accurate spectrophotometric methods for the determination of Rasagiline (RSG in pharmaceutical preparations. The determination procedures depend on the reaction of RSG with chloranilic acid for method A, tetrachloro-1,4-benzoquinone for method B, and 7,7,8,8-tetracyanoquinodimethane for method C. The colored products were quantitated spectrophotometrically at 524, 535, and 843 nm for methods A, B, and C, respectively. Different variables affecting the reaction were optimized. Linearity ranges of the methods with good correlation coefficients (0.9988–0.9996 were observed as 25–300 µg mL−1, 25–350 µg mL−1, and 50–500 µg mL−1 for methods A, B, and C, respectively. The formation of products takes place through different mechanisms. The sites of interaction were confirmed by elemental analysis using IR and 1H-NMR spectroscopy. The validation of the methods was carried out in terms of specificity, linearity, accuracy, precision, robustness, limit of detection, and limit of quantitation. No interference was observed from concomitants usually present in dosage forms. The methods were applied successfully to the determination of RSG in pharmaceutical preparations.

  3. Detection of microbial contamination in platelets

    Science.gov (United States)

    Berg, Tracy L.; Leparc, German; Huffman, Debra E.; Gennaccaro, Angela L.; Garcia-Lopez, Alicia; Klungness, Greta; Stephans, Christie; Garcia-Rubio, Luis H.

    2005-03-01

    In the United States, approximately 100 patients develop fatal sepsis associated with platelet transfusions every year. Current culture methods take 24-48 hours to acquire results, which in turn decrease the shelf life of platelets. Many of the microorganisms that contaminate platelets can replicate easily at room temperature, which is the necessary storage temperature to keep platelets functional. Therefore, there is a need for in-situ quality control assessment of the platelet quality. For this purpose, a real time spectrophotometric technique has been developed. The Spectral Acquisition Processing Detection (SAPD) method, comprised of a UV-vis spectrophotometer and modeling algorithms, is a rapid method that can be performed prior to platelet transfusion to decrease the risk of bacterial infection to patients. The SAPD method has been used to determine changes in cell suspensions, based on size, shape, chemical composition and internal structure. Changes in these cell characteristics can in turn be used to determine microbial contamination, platelet aging and other physiologic changes. Detection limits of this method for platelet suspensions seeded with bacterial contaminants were identified to be less than 100 cfu/ml of sample. Bacterial counts below 1000 cfu/ml are not considered clinically significant. The SAPD method can provide real-time identification of bacterial contamination of platelets affording patients an increased level of safety without causing undue strain on laboratory budgets or personnel while increasing the time frame that platelets can be used by dramatically shortening contaminant detection time.

  4. Micellar modified spectrophotometric determination of nitrobenzenes based upon reduction with tin(II), diazotisation and coupling with the Bratton-Marshall reagent.

    Science.gov (United States)

    Escrig-Tena, I; Alvarez Rodríguez, L; Esteve-Romero, J; García-Alvarez-Coque, M C

    1998-09-01

    Nitrobenzenes, such as the antibiotic chloramphenicol, the vasodilator nicardipine, and the herbicides dinitramin, dinobuton, fenitrothion, methylparathion, oxyfluorfen, parathion, pendimethalin, quintozene, and trifluralin, were determined by using a spectrophotometric method in the visible region (540 nm). The method was based on the reduction of the nitrobenzenes to arylamines with tin(II) chloride, diazotisation of the arylamines and coupling of the diazonium ions with the Bratton-Marshall reagent. The two latter reactions were performed in a micellar medium of sodium dodecyl sulphate. The linear calibration range was 2x10(-6) to 7x10(-5) M (r>0.999), with limits of detection in the 10(-7) M level, which is 2-6 fold lower with respect to the corresponding spectrophotometric procedure in non-micellar medium. The procedure was applied to the analysis of the compounds in commercial preparations (pharmaceuticals and herbicide formulations) and in water samples, with good recoveries.

  5. Multivariate curve resolution of incomplete fused multiset data from chromatographic and spectrophotometric analyses for drug photostability studies

    International Nuclear Information System (INIS)

    Luca, Michele De; Ragno, Gaetano; Ioele, Giuseppina; Tauler, Romà

    2014-01-01

    Highlights: • A new MCR-ALS algorithm is proposed for the analysis of incomplete fused multiset. • Resolution of the data allowed the description of amiloride kinetic photodegradation. • The new MCR-ALS algorithm can be easily applied to other drugs and chemicals. - Abstract: An advanced and powerful chemometric approach is proposed for the analysis of incomplete multiset data obtained by fusion of hyphenated liquid chromatographic DAD/MS data with UV spectrophotometric data from acid–base titration and kinetic degradation experiments. Column- and row-wise augmented data blocks were combined and simultaneously processed by means of a new version of the multivariate curve resolution-alternating least squares (MCR-ALS) technique, including the simultaneous analysis of incomplete multiset data from different instrumental techniques. The proposed procedure was applied to the detailed study of the kinetic photodegradation process of the amiloride (AML) drug. All chemical species involved in the degradation and equilibrium reactions were resolved and the pH dependent kinetic pathway described

  6. Multivariate curve resolution of incomplete fused multiset data from chromatographic and spectrophotometric analyses for drug photostability studies

    Energy Technology Data Exchange (ETDEWEB)

    Luca, Michele De, E-mail: michele.deluca@unical.it [Department of Pharmacy, Health and Nutritional Sciences, University of Calabria, Via P. Bucci, Rende, CS 87036 (Italy); Ragno, Gaetano; Ioele, Giuseppina [Department of Pharmacy, Health and Nutritional Sciences, University of Calabria, Via P. Bucci, Rende, CS 87036 (Italy); Tauler, Romà [Department of Environmental Chemistry, IDAEA-CSIC, C/Jordi Girona, 18-26, Barcelona 08034 (Spain)

    2014-07-21

    Highlights: • A new MCR-ALS algorithm is proposed for the analysis of incomplete fused multiset. • Resolution of the data allowed the description of amiloride kinetic photodegradation. • The new MCR-ALS algorithm can be easily applied to other drugs and chemicals. - Abstract: An advanced and powerful chemometric approach is proposed for the analysis of incomplete multiset data obtained by fusion of hyphenated liquid chromatographic DAD/MS data with UV spectrophotometric data from acid–base titration and kinetic degradation experiments. Column- and row-wise augmented data blocks were combined and simultaneously processed by means of a new version of the multivariate curve resolution-alternating least squares (MCR-ALS) technique, including the simultaneous analysis of incomplete multiset data from different instrumental techniques. The proposed procedure was applied to the detailed study of the kinetic photodegradation process of the amiloride (AML) drug. All chemical species involved in the degradation and equilibrium reactions were resolved and the pH dependent kinetic pathway described.

  7. Inactivation of Bacterial Spores and Vegetative Bacterial Cells by Interaction with ZnO-Fe2O3 Nanoparticles and UV Radiation

    Directory of Open Access Journals (Sweden)

    José Luis Sánchez-Salas

    2017-09-01

    Full Text Available ZnO-Fe2O3 nanoparticles (ZnO-Fe NPs were synthesized and characterized by scanning electron microscopy (SEM, energy dispersive X-ray spectroscopy (EDS and dynamic light scattering (DLS. The generation of chemical reactive hydroxyl radicals (•OH was measured spectrophotometrically (UV-Vis by monitoring of p-nitrosodimethylaniline (pNDA bleaching. Inactivation of E. coli and B. subtilis spores in the presence of different concentrations of ZnO-Fe NPs, under UV365nm or visible radiation, was evaluated. We observed the best results under visible light, of which inactivation of E. coli of about 90% was accomplished in 30 minutes, while B. subtilis inactivation close to 90% was achieved in 120 minutes. These results indicate that the prepared photocatalytic systems are promising for improving water quality by reducing the viability of water-borne microorganisms, including bacterial spores.

  8. Effect of UV-A and UV-B irradiation on the metabolic profile of aqueous humor in rabbits analyzed by 1H NMR spectroscopy.

    Science.gov (United States)

    Tessem, May-Britt; Bathen, Tone F; Cejková, Jitka; Midelfart, Anna

    2005-03-01

    This study was conducted to investigate metabolic changes in aqueous humor from rabbit eyes exposed to either UV-A or -B radiation, by using (1)H nuclear magnetic resonance (NMR) spectroscopy and unsupervised pattern recognition methods. Both eyes of adult albino rabbits were irradiated with UV-A (366 nm, 0.589 J/cm(2)) or UV-B (312 nm, 1.667 J/cm(2)) radiation for 8 minutes, once a day for 5 days. Three days after the last irradiation, samples of aqueous humor were aspirated, and the metabolic profiles analyzed with (1)H NMR spectroscopy. The metabolic concentrations in the exposed and control materials were statistically analyzed and compared, with multivariate methods and one-way ANOVA. UV-B radiation caused statistically significant alterations of betaine, glucose, ascorbate, valine, isoleucine, and formate in the rabbit aqueous humor. By using principal component analysis, the UV-B-irradiated samples were clearly separated from the UV-A-irradiated samples and the control group. No significant metabolic changes were detected in UV-A-irradiated samples. This study demonstrates the potential of using unsupervised pattern recognition methods to extract valuable metabolic information from complex (1)H NMR spectra. UV-B irradiation of rabbit eyes led to significant metabolic changes in the aqueous humor detected 3 days after the last exposure.

  9. Swift detections of the flaring blazar GAIA 18ayp (PKS 2333-415) in X-rays and the UV

    Science.gov (United States)

    Grupe, Dirk; Komossa, S.; Angioni, R.; Schartel, N.

    2018-04-01

    We report Swift observations of the z=1.41 QSO GAIA 18ayp (PKS 2333-415) which was detected by GAIA in an optically flaring state on 2018-April-14. Swift observed GAIA 18ayp on 2018 April 23 for a total of 1.4 ks. The QSO is clearly detected in X-rays and the UV. The X-ray position found using the enhanced XRT position (Goad et al. 2007, Evans et al. 2009) is RA-2000 = 23 36 34.1, Dec-2000 = -41 15 21.4 with an uncertainty of 3.0".

  10. Effects of UV irradiation and UV/chlorine co-exposure on natural organic matter in water

    International Nuclear Information System (INIS)

    Liu, Wei; Zhang, Zaili; Yang, Xin; Xu, Yiyue; Liang, Yongmei

    2012-01-01

    The effects of co-exposure to ultraviolet (UV) irradiation (with either low- or medium-pressure UV lamps) and free chlorine (chloramine) at practical relevant conditions on changes in natural organic matter (NOM) properties were investigated using four waters. The changes were characterized using the specific disinfection by-product formation potential (SDBPFP), specific total organic halogen formation potential (STOXFP), differential UV absorbance (∆UVA), and size-exclusion chromatography (SEC). The results for exposure to UV irradiation alone and for samples with no exposure were also obtained. The SDBPFPs in all UV-irradiated NOM waters observed were higher than those of non-irradiated samples. UV irradiation led to increases in STOXFPs as a result of chlorination, but no changes, or only small decreases, from chloramination. UV irradiation alone led to positive ∆UVA spectra of the four NOM waters; co-exposure to UV and chlorine gave larger negative ∆UVA spectra than those obtained by chlorine exposure alone. No obvious changes in SEC results were observed for samples only irradiated with UV light; co-exposure gave no detectable changes in the abundances of small fractions for exposure to chlorine only. Both UV photooxidation and photocatalytic oxidation appear to affect the reactivity of the NOM toward subsequent chlorination, and the magnitude of the changes is generally greater for medium-pressure lamps than for low-pressure lamps. These results suggest that applying UV disinfection technology to a particular source may not always be disinfection by-product-problem-free, and the interactions between UV light, chlorine, and NOM may need to be considered. - Highlights: ► We discussed the effects of co-exposure to UV light and chlorine on properties of natural organic matters in waters. ► UV irradiation led to increases in SDBPFP and STOXFP of NOM waters from chlorination. ► We suggest that applying an UV disinfection technology to a particular

  11. Validation of a high-performance liquid chromatographic method with UV detection for the determination of ethopabate residues in poultry liver.

    Science.gov (United States)

    Granja, Rodrigo H M M; Niño, Alfredo M Montes; Zucchetti, Roberto A M; Niño, Rosario E Montes; Salerno, Alessandro G

    2008-01-01

    Ethopabate is frequently used in the prophylaxis and treatment of coccidiosis in poultry. Residues of this drug in food present a potential risk to consumers. A simple, rapid, and sensitive column high-performance liquid chromatographic (HPLC) method with UV detection for determination of ethopabate in poultry liver is presented. The drug is extracted with acetonitrile. After evaporation, the residue is dissolved with an acetone-hexane mixture and cleaned up by solid-phase extraction using Florisil columns. The analyte is then eluted with methanol. LC analysis is carried out on a C18 5 microm Gemini column, 15 cm x 4.6 mm. Ethopabate is quantified by means of UV detection at 270 nm. Parameters such as decision limit, detection capability, precision, recovery, ruggedness, and measurement uncertainty were calculated according to method validation guidelines provided in 2002/657/EC and ISO/IEC 17025:2005. Decision limit and detection capability were determined to be 2 and 3 microg/kg, respectively. Average recoveries from poultry samples fortified with 10, 15, and 20 microg/kg levels of ethopabate were 100-105%. A complete statistical analysis was performed on the results obtained, including an estimation of the method uncertainty. The method is to be implemented into Brazil's residue monitoring and control program for ethopabate.

  12. Liquid–liquid microextraction in a multicommuted flow system for direct spectrophotometric determination of iodine value in biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Andréia C.; Rocha, Fábio R.P., E-mail: frprocha@cena.usp.br

    2014-06-01

    Highlights: • First flow-based procedure for iodine value determination in biodiesel. • Simple, fast and reliable procedure. • Detection without sample pretreatment or phase separation. • Liquid–liquid microextraction with low sample and reagent volumes. • Avoid toxic reagents and organic solvent used in the reference procedure. Abstract: A flow-based procedure was developed for the direct spectrophotometric determination of the iodine value (IV) in biodiesel. The procedure was based on the microextraction/reaction of unsaturated compounds with triiodide ions in an aqueous medium by inserting the reagent solution between the aliquots of biodiesel without any pretreatment. The interaction occurred through the biodiesel film formed on the inner walls of the hydrophobic tube used as the reactor and at the aqueous/biodiesel interfaces. The spectrophotometric detection was based on the discoloration of the I₃⁻ reagent in the aqueous phase by using a glass tube coupled to a fiber-optic spectrophotometer as the detection cell. Reference solutions were prepared by dilution of biodiesel samples with previously determined IV in hexane. The analytical response was linear for IV from 13 to 135 g I₂/100 g with a detection limit of 5 g I₂/100 g. A coefficient of variation of 1.7% (n = 10) and a sampling rate of 108 determinations per hour were achieved by consuming 224 μL of the sample and 200 μg of I₂ per determination. The slopes of analytical curves obtained with three different biodiesel samples were in agreement (variations in slopes lower than 3.1%), thus indicating an absence of any matrix effects. Results for biodiesel samples from different sources agreed with the volumetric official procedure at the 95% confidence level. The proposed procedure is therefore a simple, fast, and reliable alternative for estimating the iodine value of biodiesel.

  13. Liquid–liquid microextraction in a multicommuted flow system for direct spectrophotometric determination of iodine value in biodiesel

    International Nuclear Information System (INIS)

    Pereira, Andréia C.; Rocha, Fábio R.P.

    2014-01-01

    Highlights: • First flow-based procedure for iodine value determination in biodiesel. • Simple, fast and reliable procedure. • Detection without sample pretreatment or phase separation. • Liquid–liquid microextraction with low sample and reagent volumes. • Avoid toxic reagents and organic solvent used in the reference procedure. - Abstract: A flow-based procedure was developed for the direct spectrophotometric determination of the iodine value (IV) in biodiesel. The procedure was based on the microextraction/reaction of unsaturated compounds with triiodide ions in an aqueous medium by inserting the reagent solution between the aliquots of biodiesel without any pretreatment. The interaction occurred through the biodiesel film formed on the inner walls of the hydrophobic tube used as the reactor and at the aqueous/biodiesel interfaces. The spectrophotometric detection was based on the discoloration of the I 3 − reagent in the aqueous phase by using a glass tube coupled to a fiber-optic spectrophotometer as the detection cell. Reference solutions were prepared by dilution of biodiesel samples with previously determined IV in hexane. The analytical response was linear for IV from 13 to 135 g I 2 /100 g with a detection limit of 5 g I 2 /100 g. A coefficient of variation of 1.7% (n = 10) and a sampling rate of 108 determinations per hour were achieved by consuming 224 μL of the sample and 200 μg of I 2 per determination. The slopes of analytical curves obtained with three different biodiesel samples were in agreement (variations in slopes lower than 3.1%), thus indicating an absence of any matrix effects. Results for biodiesel samples from different sources agreed with the volumetric official procedure at the 95% confidence level. The proposed procedure is therefore a simple, fast, and reliable alternative for estimating the iodine value of biodiesel

  14. Spectrophotometric determination of pizotefin maleate in pure form ...

    African Journals Online (AJOL)

    Two simple, quick and sensitive methods were described for the spectrophotometric determination of pizotefin maleate (PZT) either in pure form or pharmaceutical form (tablets). The methods were based on the reaction of pizotefin maleate as 'n' electron donor with chloranilic acid (p-CLA) and 7,7,8 ...

  15. The determination of levofloxacin by flow injection analysis using UV detection, potentiometry, and conductometry in pharmaceutical preparations.

    Science.gov (United States)

    Altiokka, G; Atkosar, Z; Can, N O

    2002-10-15

    A flow injection analysis (FIA) using UV detection, potentiometry and conductometry for levofloxacin (LVF) are described in this study. The best solvent system was found to consist of 0.2 M acetate buffer at pH 3 having 10% MeOH. A flow rate of 1 ml min(-1) was pumped and active material was detected at 288 nm. The detection limit (LOD) and limit of quantification (LOQ) for FIA were calculated to be 3 x 10(-7) M (S/N = 3) and 1 x 10(-7) M (S/N = 10), respectively. In the analysis of tablets, the RSD values were found to be 0.83, 0.98 and 0.99 for FIA, potentiometric and conductometric methods, respectively. Copyright 2002 Elsevier Science B.V.

  16. Extraction-spectrophotometric method for silicon determination in high-purity substances. 1. Silicon determination in tellurium

    Energy Technology Data Exchange (ETDEWEB)

    Shaburova, V P; Yudelevich, I G [AN SSSR, Novosibirsk (USSR). Inst. Neorganicheskoj Khimii

    1989-01-01

    The extraction-spectrophotometric method for silicon determination in tellurium based on extraction isolation of the base by tributyl phosphate from hydrochloride solutions and with addition of HNO/sub 3/ and spectrophotometric silicon determination using malachite green is developed. The method permits to determine 2x10/sup -1/-3x10/sup -4/ % Si.

  17. Characterization of antibodies specific for UV-damaged DNA by ELISA

    Energy Technology Data Exchange (ETDEWEB)

    Eggset, G; Volden, G; Krokan, H

    1987-04-01

    The specificity of affinity purified antibodies raised against UV-irradiated DNA was examined using an enzyme-linked immunosorbent assay. DNA irradiated with UV doses higher than needed for saturation with pyrimidine dimers bound increasing amounts of antibody. Photosensitized DNA, containing high amounts of pyrimidine dimers, showed very poor binding of antibody. When UV-irradiated DNA was given a second dose of 340-nm UV light, the binding of antibodies was inhibited. Taken together, this indicates a major specificity for (6-4)-photoproducts, which are photochemically reversed by UV light in the 340-nm region. The antibodies also showed little but detectable binding to pyrimidine glycols produced in DNA by oxidation with OsO/sub 4/. Previously, we have used these antibodies for the detection of UV-induced DNA damage and its repair in human skin in vivo. These findings indicate that (6-4)-photoproducts, considered highly mutagenic, are repaired in human skin.

  18. Characterization of antibodies specific for UV-damaged DNA by ELISA

    International Nuclear Information System (INIS)

    Eggset, G.; Volden, G.; Krokan, H.; Norsk Hydro Research Centre, Porsgrunn

    1987-01-01

    The specificity of affinity purified antibodies raised against UV-irradiated DNA was examined using an enzyme-linked immunosorbent assay. DNA irradiated with UV doses higher than needed for saturation with pyrimidine dimers bound increasing amounts of antibody. Photosensitized DNA, containing high amounts of pyrimidine dimers, showed very poor binding of antibody. When UV-irradiated DNA was given a second dose of 340-nm UV light, the binding of antibodies was inhibited. Taken together, this indicates a major specificity for (6-4)-photoproducts, which are photochemically reversed by UV light in the 340-nm region. The antibodies also showed little but detectable binding to pyrimidine glycols produced in DNA by oxidation with OsO 4 . Previously, we have used these antibodies for the detection of UV-induced DNA damage and its repair in human skin in vivo. These findings indicate that (6-4)-photoproducts, considered highly mutagenic, are repaired in human skin. (author)

  19. Validated spectrophotometric methods for determination of Alendronate sodium in tablets through nucleophilic aromatic substitution reactions

    Directory of Open Access Journals (Sweden)

    Walash Mohamed I

    2012-04-01

    Full Text Available Abstract Background Alendronate (ALD is a member of the bisphosphonate family which is used for the treatment of osteoporosis, bone metastasis, Paget's disease, hypocalcaemia associated with malignancy and other conditions that feature bone fragility. ALD is a non-chromophoric compound so its determination by conventional spectrophotometric methods is not possible. So two derivatization reactions were proposed for determination of ALD through the reaction with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl and 2,4-dinitrofluorobenzene (DNFB as chromogenic derivatizing reagents. Results Three simple and sensitive spectrophotometric methods are described for the determination of ALD. Method I is based on the reaction of ALD with NBD-Cl. Method II involved heat-catalyzed derivatization of ALD with DNFB, while, Method III is based on micellar-catalyzed reaction of the studied drug with DNFB at room temperature. The reactions products were measured at 472, 378 and 374 nm, for methods I, II and III, respectively. Beer's law was obeyed over the concentration ranges of 1.0-20.0, 4.0-40.0 and 1.5-30.0 μg/mL with lower limits of detection of 0.09, 1.06 and 0.06 μg/mL for Methods I, II and III, respectively. The proposed methods were applied for quantitation of the studied drug in its pure form with mean percentage recoveries of 100.47 ± 1.12, 100.17 ± 1.21 and 99.23 ± 1.26 for Methods I, II and III, respectively. Moreover the proposed methods were successfully applied for determination of ALD in different tablets. Proposals of the reactions pathways have been postulated. Conclusion The proposed spectrophotometric methods provided sensitive, specific and inexpensive analytical procedures for determination of the non-chromophoric drug alendronate either per se or in its tablet dosage forms without interference from common excipients. Graphical abstract

  20. Yonsei Evolutionary Population Synthesis (YEPS). II. Spectro-photometric Evolution of Helium-enhanced Stellar Populations

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Chul; Yoon, Suk-Jin; Lee, Young-Wook, E-mail: chulchung@yonsei.ac.kr, E-mail: sjyoon0691@yonsei.ac.kr [Center for Galaxy Evolution Research, Yonsei University, Seoul 03722 (Korea, Republic of)

    2017-06-20

    The discovery of multiple stellar populations in Milky Way globular clusters (GCs) has stimulated various follow-up studies on helium-enhanced stellar populations. Here we present the evolutionary population synthesis models for the spectro-photometric evolution of simple stellar populations (SSPs) with varying initial helium abundance ( Y {sub ini}). We show that Y {sub ini} brings about dramatic changes in spectro-photometric properties of SSPs. Like the normal-helium SSPs, the integrated spectro-photometric evolution of helium-enhanced SSPs is also dependent on metallicity and age for a given Y {sub ini}. We discuss the implications and prospects for the helium-enhanced populations in relation to the second-generation populations found in the Milky Way GCs. All of the models are available at http://web.yonsei.ac.kr/cosmic/data/YEPS.htm.

  1. Yonsei Evolutionary Population Synthesis (YEPS). II. Spectro-photometric Evolution of Helium-enhanced Stellar Populations

    International Nuclear Information System (INIS)

    Chung, Chul; Yoon, Suk-Jin; Lee, Young-Wook

    2017-01-01

    The discovery of multiple stellar populations in Milky Way globular clusters (GCs) has stimulated various follow-up studies on helium-enhanced stellar populations. Here we present the evolutionary population synthesis models for the spectro-photometric evolution of simple stellar populations (SSPs) with varying initial helium abundance ( Y ini ). We show that Y ini brings about dramatic changes in spectro-photometric properties of SSPs. Like the normal-helium SSPs, the integrated spectro-photometric evolution of helium-enhanced SSPs is also dependent on metallicity and age for a given Y ini . We discuss the implications and prospects for the helium-enhanced populations in relation to the second-generation populations found in the Milky Way GCs. All of the models are available at http://web.yonsei.ac.kr/cosmic/data/YEPS.htm.

  2. Direct DOC and nitrate determination in water using dual pathlength and second derivative UV spectrophotometry.

    Science.gov (United States)

    Causse, Jean; Thomas, Olivier; Jung, Aude-Valérie; Thomas, Marie-Florence

    2017-01-01

    UV spectrophotometry is largely used for water and wastewater quality monitoring. The measurement/estimation of specific and aggregate parameters such as nitrate and dissolved organic carbon (DOC) is possible with UV spectra exploitation, from 2 to multi wavelengths calibration. However, if nitrate determination from UV absorbance is known, major optical interferences linked to the presence of suspended solids, colloids or dissolved organic matter limit the relevance of UV measurement for DOC assessment. A new method based on UV spectrophotometric measurement of raw samples (without filtration) coupling a dual pathlength for spectra acquisition and the second derivative exploitation of the signal is proposed in this work. The determination of nitrate concentration is carried out from the second derivative of the absorbance at 226 nm corresponding at the inflexion point of nitrate signal decrease. A short optical pathlength can be used considering the strong absorption of nitrate ion around 210 nm. For DOC concentration determination the second derivative absorbance at 295 nm is proposed after nitrate correction. Organic matter absorbing slightly in the 270-330 nm window, a long optical pathlength must be selected in order to increase the sensitivity. The method was tested on several hundred of samples from small rivers of two agricultural watersheds located in Brittany, France, taken during dry and wet periods. The comparison between the proposed method and the standardised procedures for nitrate and DOC measurement gave a good adjustment for both parameters for ranges of 2-100 mg/L NO3 and 1-30 mg/L DOC. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. The “UV-route” to Search for Blue Straggler Stars in Globular Clusters: First Results from the HST UV Legacy Survey

    Energy Technology Data Exchange (ETDEWEB)

    Raso, S.; Ferraro, F. R.; Lanzoni, B. [Department of Physics and Astronomy, University of Bologna, Viale Berti Pichat, 6/2, Bologna (Italy); Dalessandro, E. [INAF Osservatorio Astronomico di Bologna, Via Ranzani 1, Bologna (Italy); Nardiello, D. [Department of Physics and Astronomy Galileo Galilei, University of Padova, Vicolo dell’Osservatorio 3, I-35122 Padova (Italy); Bellini, A. [Space Telescope Science Institute, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Vesperini, E. [Department of Astronomy, Indiana University, Bloomington, IN, 47401 (United States)

    2017-04-10

    We used data from the Hubble Space Telescope UV Legacy Survey of Galactic Globular Clusters to select the Blue Straggler Star (BSS) population in four intermediate/high density systems (namely NGC 2808, NGC 6388, NGC 6541, and NGC 7078) through a “UV-guided search.” This procedure consists of using the F275W images in each cluster to construct the master list of detected sources, and then force it to the images acquired in the other filters. Such an approach optimizes the detection of relatively hot stars and allows the detection of a complete sample of BSSs even in the central region of high-density clusters, because the light from the bright cool giants, which dominates the optical emission in old stellar systems, is sensibly reduced at UV wavelengths. Our UV-guided selections of BSSs have been compared to the samples obtained in previous, optical-driven surveys, clearly demonstrating the efficiency of the UV approach. In each cluster we also measured the parameter A {sup +}, defined as the area enclosed between the cumulative radial distribution of BSSs and that of a reference population, which traces the level of BSS central segregation and the level of dynamical evolution suffered by the system. The values measured for the four clusters studied in this paper nicely fall along the dynamical sequence recently presented for a sample of 25 clusters.

  4. Method development for arsenic analysis by modification in spectrophotometric technique

    Directory of Open Access Journals (Sweden)

    M. A. Tahir

    2012-01-01

    Full Text Available Arsenic is a non-metallic constituent, present naturally in groundwater due to some minerals and rocks. Arsenic is not geologically uncommon and occurs in natural water as arsenate and arsenite. Additionally, arsenic may occur from industrial discharges or insecticide application. World Health Organization (WHO and Pakistan Standard Quality Control Authority have recommended a permissible limit of 10 ppb for arsenic in drinking water. Arsenic at lower concentrations can be determined in water by using high tech instruments like the Atomic Absorption Spectrometer (hydride generation. Because arsenic concentration at low limits of 1 ppb can not be determined easily with simple spectrophotometric technique, the spectrophotometric technique using silver diethyldithiocarbamate was modified to achieve better results, up to the extent of 1 ppb arsenic concentration.

  5. Spectrophotometric and Refractometric Determination of Total Protein in Avian Plasma

    Directory of Open Access Journals (Sweden)

    Rodica Căpriță

    2013-10-01

    Full Text Available The aim of this study was to compare the total protein values obtained in heparin plasma of chickens by a spectrophotometric technique (biuret method, and the values obtained on the same day in the same samples by refractometry. The results obtained by refractometry (average value 2.638±0.153g% were higher than those obtained by the spectrophotometric method (average value 2.441±0.181g%. There was a low correlation (r = 0.6709 between the total protein values, determined with both methods. Protein is the major determinant of plasma refractive index, but glucose contributes too. The refractometric method is not recommended in chickens for the determination of total protein, because avian blood glucose concentration averages about twice than in mammalian blood.

  6. Extraction of phenolic compounds from extra virgin olive oil by a natural deep eutectic solvent: Data on UV absorption of the extracts

    Directory of Open Access Journals (Sweden)

    Vito Michele Paradiso

    2016-09-01

    Full Text Available This data article refers to the paper “Towards green analysis of virgin olive oil phenolic compounds: extraction by a natural deep eutectic solvent and direct spectrophotometric detection” [1]. A deep eutectic solvent (DES based on lactic acid and glucose was used as green solvent for phenolic compounds. Eight standard phenolic compounds were solubilized in the DES. Then, a set of extra virgin olive oil (EVOO samples (n=65 were submitted to liquid–liquid extraction by the DES. The standard solutions and the extracts were analyzed by UV spectrophotometry. This article reports the spectral data of both the standard solutions and the 65 extracts, as well as the total phenolic content of the corresponding oils, assessed by the Folin–Ciocalteu assay. Keywords: Natural deep eutectic solvents, Extra virgin olive oil, Phenolic compounds, UV spectrophotometry

  7. Detection of Outliers and Imputing of Missing Values for Water Quality UV-VIS Absorbance Time Series

    Directory of Open Access Journals (Sweden)

    Leonardo Plazas-Nossa

    2017-01-01

    Full Text Available Context: The UV-Vis absorbance collection using online optical captors for water quality detection may yield outliers and/or missing values. Therefore, data pre-processing is a necessary pre-requisite to monitoring data processing. Thus, the aim of this study is to propose a method that detects and removes outliers as well as fills gaps in time series. Method: Outliers are detected using Winsorising procedure and the application of the Discrete Fourier Transform (DFT and the Inverse of Fast Fourier Transform (IFFT to complete the time series. Together, these tools were used to analyse a case study comprising three sites in Colombia ((i Bogotá D.C. Salitre-WWTP (Waste Water Treatment Plant, influent; (ii Bogotá D.C. Gibraltar Pumping Station (GPS; and, (iii Itagüí, San Fernando-WWTP, influent (Medellín metropolitan area analysed via UV-Vis (Ultraviolet and Visible spectra. Results: Outlier detection with the proposed method obtained promising results when window parameter values are small and self-similar, despite that the three time series exhibited different sizes and behaviours. The DFT allowed to process different length gaps having missing values. To assess the validity of the proposed method, continuous subsets (a section of the absorbance time series without outlier or missing values were removed from the original time series obtaining an average 12% error rate in the three testing time series. Conclusions: The application of the DFT and the IFFT, using the 10% most important harmonics of useful values, can be useful for its later use in different applications, specifically for time series of water quality and quantity in urban sewer systems. One potential application would be the analysis of dry weather interesting to rain events, a feat achieved by detecting values that correspond to unusual behaviour in a time series. Additionally, the result hints at the potential of the method in correcting other hydrologic time series.

  8. Spectrophotometric and theoretical studies on the determination of ...

    African Journals Online (AJOL)

    Purpose: To develop a simple and cost effective spectrophotometric method for the ... species exhibited absorption maxima at 410 and 479 nm for the two systems in ... etilefrine in plasma and urine in pharmacokinetic ... In this work, the interactions of ET with BCG and ... prepared where the total volume of investigated.

  9. Investigation of Drug–Polymer Compatibility Using Chemometric-Assisted UV-Spectrophotometry

    Directory of Open Access Journals (Sweden)

    Amir Ibrahim Mohamed

    2017-01-01

    Full Text Available A simple chemometric-assisted UV-spectrophotometric method was used to study the compatibility of clindamycin hydrochloride (HC1 with two commonly used natural controlled-release polymers, alginate (Ag and chitosan (Ch. Standard mixtures containing 1:1, 1:2, and 1:0.5 w/w drug–polymer ratios were prepared and UV scanned. A calibration model was developed with partial least square (PLS regression analysis for each polymer separately. Then, test mixtures containing 1:1 w/w drug–polymer ratios with different sets of drug concentrations were prepared. These were UV scanned initially and after three and seven days of storage at 25 °C. Using the calibration model, the drug recovery percent was estimated and a decrease in concentration of 10% or more from initial concentration was considered to indicate instability. PLS models with PC3 (for Ag and PC2 (for Ch showed a good correlation between actual and found values with root mean square error of cross validation (RMSECV of 0.00284 and 0.01228, and calibration coefficient (R2 values of 0.996 and 0.942, respectively. The average drug recovery percent after three and seven days was 98.1 ± 2.9 and 95.4 ± 4.0 (for Ag, and 97.3 ± 2.1 and 91.4 ± 3.8 (for Ch, which suggests more drug compatibility with an Ag than a Ch polymer. Conventional techniques including DSC, XRD, FTIR, and in vitro minimum inhibitory concentration (MIC for (1:1 drug–polymer mixtures were also performed to confirm clindamycin compatibility with Ag and Ch polymers.

  10. [Spectrophotometric and HPLC evaluation of ceftazidime stability].

    Science.gov (United States)

    Palade, B; Cioroiu, B; Lazăr, Doina; Corciovă, Andreia; Lazăr, M I

    2010-01-01

    In this paper we followed up the stability of ceftazidime, raw material used in drug industry. Matherials and methods: We used three spectrophotometric methods based on ceftazidime property to form complexes with p-chloranilic acid (ac. p-CA), 3-methylbenzothiazolin-2-on hydrazone (MBTH) and N-(1-naphtil) etilendiamine (NEDA) and a chromatographic method (HPLC). Our results revealed that the substances analyzed maintained minimum content allowable.

  11. Salicylate-spectrophotometric determination of inorganic monochloramine

    International Nuclear Information System (INIS)

    Tao Hui; Chen Zhonglin; Li Xing; Yang Yanling; Li Guibai

    2008-01-01

    On the basis of classical Berthelot reaction, a simple salicylate-spectrophotometric method was developed for quantitative determination of inorganic monochloramine in water samples. With the catalysis of disodium pentacyanonitrosylferrate(III), inorganic monochloramine reacts with salicylate in equimolar to produce indophenol compound which has an intense absorption at 703 nm. Parameters that influence method performance, such as pH, dosage of salicylate and nitroprussiate and reaction time, were modified to enhance the method performance. By using this method, inorganic monochloramine can be distinguished from organic chloramines and other inorganic chlorine species, such as free chlorine, dichloramine, and trichloramine. The molar absorptivities of the final products formed by these compounds are below ±3% of inorganic monochloramine, because of the α-N in them have only one exchangeable hydrogen atom, and cannot react with salicylate to produce the indophenol compound. The upper concentrations of typical ions that do not interfere with the inorganic monochloramine determination are also tested to be much higher than that mostly encountered in actual water treatment. Case study demonstrates that the results obtained from this method are lower than DPD-titrimetric method because the organic chloramines formed by chlorination of organic nitrogenous compounds give no response in the newly established method. And the result measured by salicylate-spectrophotometric method is coincident with theoretical calculation

  12. The effect of UV-B and UV-C radiation on Hibiscus leaves determined by ultraweak luminescence and fluorescence induction [chlorophyll fluorescence induction, ultraweak luminescence

    International Nuclear Information System (INIS)

    Panagopoulos, I.; Bornman, J.F.; Björn, L.O.

    1989-01-01

    The effects of UV-C (254 nm) and UV-B (280-320 nm) on chlorophyll fluorescence induction and ultraweak luminescence (UL) in detached leaves of Hibiscus rosa-sinensis L. were investigated. UL from leaves exposed to UV-B and UV-C radiation reached a maximum 72 h after irradiation. In both cases most of the light was of a wavelength over 600 nm. An increase in the percentage of long wavelength light with time was detected. UV radiation increased peroxidase activity, which also reached a maximum 72 h after irradiation. UV-B and UV-C both reduced variable chlorophyll fluorescence. No effect on the amount of chlorophyll or UV screening pigments was observed with the short-term irradiation used in this investigation. (author)

  13. Effect of bilirubin on the spectrophotometric and radionuclide assay for serum angiotensin-converting enzyme

    International Nuclear Information System (INIS)

    Saxe, A.W.; Hollinger, M.A.; Essam, T.

    1986-01-01

    The effect of bilirubin on serum angiotensin-converting enzyme (ACE) activity was studied with spectrophotometric and radionuclide assays. In the spectrophotometric assay addition of bilirubin to normal serum from dog, mouse, and human produced a dose-related inhibition of ACE activity. A 50% decrease in human ACE activity was produced by the addition of approximately 250 mg/L in vitro. Serum from icteric patients with elevated bilirubin was also associated with a reduction in ACE activity in the spectrophotometric assay. A 50% decrease in ACE activity in these samples was associated with a serum bilirubin of approximately 220 mg/L. In the radionuclide assay, however, addition of bilirubin to normal human serum failed to reduce measured ACE activity. The use of a radionuclide assay for serum ACE in clinical samples offers the advantage of less interference from serum bilirubin

  14. Spectrophotometric, colorimetric and visually detection of Pseudomonas aeruginosa ETA gene based gold nanoparticles DNA probe and endonuclease enzyme

    Science.gov (United States)

    Amini, Bahram; Kamali, Mehdi; Salouti, Mojtaba; Yaghmaei, Parichehreh

    2018-06-01

    Colorimetric DNA detection is preferred over other methods for clinical molecular diagnosis because it does not require expensive equipment. In the present study, the colorimetric method based on gold nanoparticles (GNPs) and endonuclease enzyme was used for the detection of P. aeruginosa ETA gene. Firstly, the primers and probe for P. aeruginosa exotoxin A (ETA) gene were designed and checked for specificity by the PCR method. Then, GNPs were synthesized using the citrate reduction method and conjugated with the prepared probe to develop the new nano-biosensor. Next, the extracted target DNA of the bacteria was added to GNP-probe complex to check its efficacy for P. aeruginosa ETA gene diagnosis. A decrease in absorbance was seen when GNP-probe-target DNA cleaved into the small fragments of BamHI endonuclease due to the weakened electrostatic interaction between GNPs and the shortened DNA. The right shift of the absorbance peak from 530 to 562 nm occurred after adding the endonuclease. It was measured using a UV-VIS absorption spectroscopy that indicates the existence of the P. aeruginosa ETA gene. Sensitivity was determined in the presence of different concentrations of target DNA of P. aeruginosa. The results obtained from the optimized conditions showed that the absorbance value has linear correlation with concentration of target DNA (R: 0.9850) in the range of 10-50 ng mL-1 with the limit detection of 9.899 ng mL-1. Thus, the specificity of the new method for detection of P. aeruginosa was established in comparison with other bacteria. Additionally, the designed assay was quantitatively applied to detect the P. aeruginosa ETA gene from 103 to 108 CFU mL-1 in real samples with a detection limit of 320 CFU mL-1.

  15. A novel method for spectrophotometric determination of pregabalin in pure form and in capsules

    Directory of Open Access Journals (Sweden)

    Gaur Prateek

    2011-10-01

    Full Text Available Abstract Background Pregabalin, a γ-amino-n-butyric acid derivative, is an antiepileptic drug not yet official in any pharmacopeia and development of analytical procedures for this drug in bulk/formulation forms is a necessity. We herein, report a new, simple, extraction free, cost effective, sensitive and reproducible spectrophotometric method for the determination of the pregabalin. Results Pregabalin, as a primary amine was reacted with ninhydrin in phosphate buffer pH 7.4 to form blue violet colored chromogen which could be measured spectrophotometrically at λmax 402.6 nm. The method was validated with respect to linearity, accuracy, precision and robustness. The method showed linearity in a wide concentration range of 50-1000 μg mL-1 with good correlation coefficient (0.992. The limits of assays detection was found to be 6.0 μg mL-1 and quantitation limit was 20.0 μg mL-1. The suggested method was applied to the determination of the drug in capsules. No interference could be observed from the additives in the capsules. The percentage recovery was found to be 100.43 ± 1.24. Conclusion The developed method was successfully validated and applied to the determination of pregabalin in bulk and pharmaceutical formulations without any interference from common excipients. Hence, this method can be potentially useful for routine laboratory analysis of pregabalin.

  16. Effect of uvs1, uvs2 and xrs mutations on the radiosensitivity and the induced mitotic recombination frequency in diploid yeast cells

    International Nuclear Information System (INIS)

    Suslova, N.G.; Fedorova, I.V.; Zheleznyakova, N.Yu.

    1975-01-01

    The influence of the loci of radiosensitivity uvs1, uvs2, and xrs in the homozygous state at the diploid level on the sensitivity to UV and ionizing radiation and induced mitotic recombination was studied in the yeast Sacch. cerevisiae. Hypersensitivity to UV irradiation was detected in the diploids uvs2 uvs2 xrs xrs in comparision with the corresponding control. The diploid uvs1 uvs1 uvs2 uvs2 does not differ in UV sensitivity from the diploid uvs1 uvs1 UVS2 UVS2. These facts demonstrate that the uvs1 and uvs2 mutations, on the one hand, and the xrs mutations, on the other, normally control different pathways of elimination of UV-induced damages. It was shown that the diploid uvs2 uvs2 xrs3 xrs3 is far more sensitive to the lethal action of x rays than the control diploid UVS2 UVS2 xrs3 xrs3. Consequently, the mutations uvs2 and xrs3 block different modes of repair of damages induced by ionizing radiation. In all the double-mutant diploids, the frequency of mitotic recombination induced by UV rays increases sharply in comparison with that of the radioresistant diploids UVS UVS XRS XRS and the UV-sensitive diploids uvs2 uvs2 XRS XRS. Possible causes of the observed phenomenon are discussed. It was established that in a diploid homozygous for the loci uvs2 xrs5, the frequency of mitotic recombination induced by x rays increases extremely sharply. This fact confirms the hypothesis that the gene product of the locus uvs2 participates in the repair of DNA after the action of ionizing radiation. (author)

  17. New simple spectrophotometric assay of total carotenes in margarines

    NARCIS (Netherlands)

    Luterotti, S.; Bicanic, D.D.; Pozgaj, R.

    2006-01-01

    Direct and reliable spectrophotometric method for assaying total carotenes (TC) in margarines with the minimum of sample manipulation is proposed. For the first time saponification step used in determination of carotenes in margarines was omitted leading to a substantial cost saving and reduction of

  18. Study of imidaclopride removal from aqueous solution by adsorption onto granular activated carbon using an on-line spectrophotometric analysis system

    International Nuclear Information System (INIS)

    Daneshvar, N.; Aber, S.; Khani, A.; Khataee, A.R.

    2007-01-01

    The removal of imidaclopride as a pesticide by granular activated carbon (GAC) and its adsorption kinetics were studied at different pH values and temperatures. In all experiments, the amount of GAC and initial concentration of imidaclopride were 2 g and 25 ppm, respectively. The adsorption process was followed by an on-line spectrophotometric analysis system, which consisted of UV-spectrophotometer, a designed absorption cell, peristaltic pump and special glassy reactor. The effect of pH and temperature on adsorption was studied over 90 min adsorption periods. The obtained data were treated according to various kinetic models. The results showed that second order model was the most suitable one on the overall. The our results also showed that the adsorption rate constants for first order, second order and intraparticle diffusion models followed decreasing order: pH = 7 > 4 > 10 > 1, T = 25 > 35 > 45 > 55 deg. C

  19. Study of imidaclopride removal from aqueous solution by adsorption onto granular activated carbon using an on-line spectrophotometric analysis system

    Energy Technology Data Exchange (ETDEWEB)

    Daneshvar, N. [Water and Wastewater Treatment Research Laboratory, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz (Iran, Islamic Republic of)]. E-mail: nezam_daneshvar@yahoo.com; Aber, S. [Water and Wastewater Treatment Research Laboratory, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz (Iran, Islamic Republic of)]. E-mail: soheil_aber@yahoo.com; Khani, A. [Water and Wastewater Treatment Research Laboratory, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz (Iran, Islamic Republic of)]. E-mail: alikhani_chemwt@yahoo.com; Khataee, A.R. [Water and Wastewater Treatment Research Laboratory, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz (Iran, Islamic Republic of)]. E-mail: ar_khataee@yahoo.com

    2007-06-01

    The removal of imidaclopride as a pesticide by granular activated carbon (GAC) and its adsorption kinetics were studied at different pH values and temperatures. In all experiments, the amount of GAC and initial concentration of imidaclopride were 2 g and 25 ppm, respectively. The adsorption process was followed by an on-line spectrophotometric analysis system, which consisted of UV-spectrophotometer, a designed absorption cell, peristaltic pump and special glassy reactor. The effect of pH and temperature on adsorption was studied over 90 min adsorption periods. The obtained data were treated according to various kinetic models. The results showed that second order model was the most suitable one on the overall. The our results also showed that the adsorption rate constants for first order, second order and intraparticle diffusion models followed decreasing order: pH = 7 > 4 > 10 > 1, T = 25 > 35 > 45 > 55 deg. C.

  20. Degradation of sulfamethoxazole by UV, UV/H2O2 and UV/persulfate (PDS): Formation of oxidation products and effect of bicarbonate.

    Science.gov (United States)

    Yang, Yi; Lu, Xinglin; Jiang, Jin; Ma, Jun; Liu, Guanqi; Cao, Ying; Liu, Weili; Li, Juan; Pang, Suyan; Kong, Xiujuan; Luo, Congwei

    2017-07-01

    The frequent detection of sulfamethoxazole (SMX) in wastewater and surface waters gives rise of concerns about their ecotoxicological effects and potential risks to induce antibacterial resistant genes. UV/hydrogen peroxide (UV/H 2 O 2 ) and UV/persulfate (UV/PDS) advanced oxidation processes have been demonstrated to be effective for the elimination of SMX, but there is still a need for a deeper understanding of product formations. In this study, we identified and compared the transformation products of SMX in UV, UV/H 2 O 2 and UV/PDS processes. Because of the electrophilic nature of SO 4 - , the second-order rate constant for the reaction of sulfate radical (SO 4 - ) with the anionic form of SMX was higher than that with the neutral form, while hydroxyl radical (OH) exhibited comparable reactivity to both forms. The direct photolysis of SMX predominately occurred through cleavage of the NS bond, rearrangement of the isoxazole ring, and hydroxylation mechanisms. Hydroxylation was the dominant pathway for the reaction of OH with SMX. SO 4 - favored attack on NH 2 group of SMX to generate a nitro derivative and dimeric products. The presence of bicarbonate in UV/H 2 O 2 inhibited the formation of hydroxylated products, but promoted the formation of the nitro derivative and the dimeric products. In UV/PDS, bicarbonate increased the formation of the nitro derivative and the dimeric products, but decreased the formation of the hydroxylated dimeric products. The different effect of bicarbonate on transformation products in UV/H 2 O 2 vs. UV/PDS suggested that carbonate radical (CO 3 - ) oxidized SMX through the electron transfer mechanism similar to SO 4 - but with less oxidation capacity. Additionally, SO 4 - and CO 3 - exhibited higher reactivity to the oxazole ring than the isoxazole ring of SMX. Ecotoxicity of transformation products was estimated by ECOSAR program based on the quantitative structure-activity relationship analysis as well as by experiments using

  1. Enzymatic determination of photoproducts in DNA molecules damaged by UV radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kleibl, K; Brozmanova, J [Slovenska Akademia Vied, Bratislava (Czechoslovakia). Ustav Experimentalnej Onkologie

    1981-01-01

    Two basic analytical procedures are described for the detection of photoproducts in UV-irradiated DNA. In the former, the selective release of thymine dimers of the cyclobutane type (TT) from the UV-irradiated DNA during excision repair can be measured by chromatographic analysis of radioactive DNA hydrolysis products. The technique allows studying TT irrespective of other products. It is only reliable for UV doses higher than 5 Jm/sup -2/. In the latter, a Micrococcus luteus extract containing specific enzymes, ie., endonucleases, for the repair of UV-induced damage of DNA is used for the enzyme determination of pyrimidine dimers. The endonucleotide analysis of DNA damage can be applied both in vitro and in vivo. In the in-vitro detection, the efficacy of photoproduct determination attains almost 100% while in the in-vivo detection it ranges between 30% and 70% in dependence on the method used. 31 references are given.

  2. NEW SPECTROPHOTOMETRIC METHOD WITH KMnO 4 FOR ...

    African Journals Online (AJOL)

    The new method, an instrument-based and simple experimental procedure involves the reaction of the hypochlorite with arsenious oxide (As2O3) (pH 6.5) followed by the coupled reaction of residual As2O3 with permanganate at acidic pH. A titration procedure is described and spectrophotometric method is designed using ...

  3. Comparative evaluation of UV/VIS and HPLC analytical methodologies applied for quantification of flavonoids from leaves of Bauhinia forficata

    Directory of Open Access Journals (Sweden)

    Graziella S. Marques

    2012-12-01

    Full Text Available Spectrophotometric determinations (direct dilution or after acid hydrolysis of flavonoid content in leaves of Bauhinia forficata Link, Fabaceae, from two different regions from Brazil were compared with contents of kaempferitrin quantified by HPLC analysis. The absence of kaempferitrin peak in one sample denotes the risk of LC-method failure. On the other hand, the both spectrophotometric assays showed satisfactory performance and do not underwent influence from absence of kaempferitrin. Since several flavonoids are present in the herbal material, different content of flavonoids were observed for each analytical procedure. However, a strong positive association could be detected among methods (R²>0.99. Although a conversion factor should be adopted to compare procedures, the data showed that the spectrophotometric methods remain as an important tool for analysis of complex matrices such herbal drugs, notably when there aren't any pharmacological or chemical marker established for the species. Moreover, it's possible to suggest that the techniques studied in this work exhibit similar performance under the conditions employed. Nevertheless, before the adoption of kaempferitrin as an analytical marker by HPLC for Bauhinia species, the pharmacological knowledge should be better developed. In this cases, the use of spectrophotometric assay provide higher assurance of the reproducibility of the efficacy and safety.

  4. Comparative evaluation of UV/VIS and HPLC analytical methodologies applied for quantification of flavonoids from leaves of Bauhinia forficata

    Directory of Open Access Journals (Sweden)

    Graziella S. Marques

    2013-02-01

    Full Text Available Spectrophotometric determinations (direct dilution or after acid hydrolysis of flavonoid content in leaves of Bauhinia forficata Link, Fabaceae, from two different regions from Brazil were compared with contents of kaempferitrin quantified by HPLC analysis. The absence of kaempferitrin peak in one sample denotes the risk of LC-method failure. On the other hand, the both spectrophotometric assays showed satisfactory performance and do not underwent influence from absence of kaempferitrin. Since several flavonoids are present in the herbal material, different content of flavonoids were observed for each analytical procedure. However, a strong positive association could be detected among methods (R²>0.99. Although a conversion factor should be adopted to compare procedures, the data showed that the spectrophotometric methods remain as an important tool for analysis of complex matrices such herbal drugs, notably when there aren't any pharmacological or chemical marker established for the species. Moreover, it's possible to suggest that the techniques studied in this work exhibit similar performance under the conditions employed. Nevertheless, before the adoption of kaempferitrin as an analytical marker by HPLC for Bauhinia species, the pharmacological knowledge should be better developed. In this cases, the use of spectrophotometric assay provide higher assurance of the reproducibility of the efficacy and safety.

  5. Online in-tube microextractor coupled with UV-Vis spectrophotometer for bisphenol A detection.

    Science.gov (United States)

    Poorahong, Sujittra; Thammakhet, Chongdee; Thavarungkul, Panote; Kanatharana, Proespichaya

    2013-01-01

    A simple and high extraction efficiency online in-tube microextractor (ITME) was developed for bisphenol A (BPA) detection in water samples. The ITME was fabricated by a stepwise electrodeposition of polyaniline, polyethylene glycol and polydimethylsiloxane composite (CPANI) inside a silico-steel tube. The obtained ITME coupled with UV-Vis detection at 278 nm was investigated. By this method, the extraction and pre-concentration of BPA in water were carried out in a single step. Under optimum conditions, the system provided a linear dynamic range of 0.1 to 100 μM with a limit of detection of 20 nM (S/N ≥3). A single in-tube microextractor had a good stability of more than 60 consecutive injections for 10.0 μM BPA with a relative standard deviation of less than 4%. Moreover, a good tube-to-tube reproducibility and precision were obtained. The system was applied to detect BPA in water samples from six brands of baby bottles and the results showed good agreement with those obtained from the conventional GC-MS method. Acceptable percentage recoveries from the spiked water samples were obtained, ranging from 83-102% for this new method compared with 73-107% for the GC-MS standard method. This new in-tube CPANI microextractor provided an excellent extraction efficiency and a good reproducibility. In addition, it can also be easily applied for the analysis of other polar organic compounds contaminated in water sample.

  6. DNA metabolism in peripheral lymphocytes of UV-B wholebody irradiated men

    International Nuclear Information System (INIS)

    Klein, W.; Kocsis, F.; Altmann, H.

    1983-02-01

    Healthy probands were UV-B irradiated and different times after the treatment blood was taken and lymphocytes were isolated. Semiconservative DNA-synthesis was enhanced after 4 in vivo expositions. DNA repair replication in lymphocytes after in vitro UV-C damage was initially increased in UV-B wholebody irradiated people. With nucleoidsedimentation DNA strand breaks after in vivo UV-B irradiation were detected. (Author) [de

  7. Spectrophotometric determination of nitrite based on its catalytic effect on the reaction of nuclear fast red and potassium bromate

    Directory of Open Access Journals (Sweden)

    HASSAN ZAVVAR MOUSAVI

    2009-08-01

    Full Text Available A highly selective and sensitive catalytic spectrophotometric method was developed for the determination of nitrite in water samples. The method is based on its catalytic effect on the nuclear fast red–potassium bromate redox reaction in acidic medium. The reaction was followed spectrophotometrically by measuring the change in the absorbance at 518 nm of nuclear fast red 5 min after initiation of the reaction. In this study, the experimental parameters were optimized and the effects of other cations and anions on the determination of nitrite were examined. The calibration graph was linear in the range 2.0–45 µg mL-1 of nitrite. The relative standard deviations for the determination of 15 and 30 µg mL-1 of nitrite were 3.1 and 1.75 %, respectively (n = 8. The detection limit calculated from three times the standard deviation of the blank 3Sb was 0.7 µg mL-1. The method was successfully applied to the determination of nitrite in spiked tap, natural and wastewater samples.

  8. High-Performance Visible-Blind UV Phototransistors Based on n-Type Naphthalene Diimide Nanomaterials.

    Science.gov (United States)

    Song, Inho; Lee, Seung-Chul; Shang, Xiaobo; Ahn, Jaeyong; Jung, Hoon-Joo; Jeong, Chan-Uk; Kim, Sang-Wook; Yoon, Woojin; Yun, Hoseop; Kwon, O-Pil; Oh, Joon Hak

    2018-04-11

    This study investigates the performance of single-crystalline nanomaterials of wide-band gap naphthalene diimide (NDI) derivatives with methylene-bridged aromatic side chains. Such materials are found to be easily used as high-performance, visible-blind near-UV light detectors. NDI single-crystalline nanoribbons are assembled using a simple solution-based process (without solvent-inclusion problems), which is then applied to organic phototransistors (OPTs). Such OPTs exhibit excellent n-channel transistor characteristics, including an average electron mobility of 1.7 cm 2 V -1 s -1 , sensitive UV detection properties with a detection limit of ∼1 μW cm -2 , millisecond-level responses, and detectivity as high as 10 15 Jones, demonstrating the highly sensitive organic visible-blind UV detectors. The high performance of our OPTs originates from the large face-to-face π-π stacking area between the NDI semiconducting cores, which is facilitated by methylene-bridged aromatic side chains. Interestingly, NDI-based nanoribbon OPTs exhibit a distinct visible-blind near-UV detection with an identical detection limit, even under intense visible light illumination (for example, 10 4 times higher intensity than UV light intensity). Our findings demonstrate that wide-band gap NDI-based nanomaterials are highly promising for developing high-performance visible-blind UV photodetectors. Such photodetectors could potentially be used for various applications including environmental and health-monitoring systems.

  9. Determination of phenol in locally grown fruits and vegetable by spectrophotometric method

    International Nuclear Information System (INIS)

    Iqbal, M.; Khan, F.A.; Farooqui, Z.H.; Ifrahim, A.F.K.

    2005-01-01

    Spectrophotometric method for the determination of phenol in the sample of locally grown fruits apple, pear, sweet orange and vegetable radish of Quetta, Hyderabad and Nawabshah are described juices from these fruits and vegetable were squeezed, filtered and decolorized with charcoal. The antipyrine dye formed by reaction between phenol and 4-aminoantipyrine was analyzed. The calibration graphs were prepared in the range of 0.5 to 4 ppm of phenol. Phenol in apple, pear and sweet orange was found to be in the range of 1-1.2 ppm and in radish was found to be 0.5 ppm. Possible source of organic pollutant were pointed out and were discussed. Limits of detection of the method was investigated and was found to be 0.2 mu g/ml

  10. The Aspergillus uvsH gene encodes a product homologous to yeast RAD18 and Neurospora UVS-2.

    Science.gov (United States)

    Yoon, J H; Lee, B J; Kang, H S

    1995-07-28

    The uvsH DNA repair gene of Aspergillus nidulans has been cloned by complementation of the uvsH77 mutation with a cosmid library containing genomic DNA inserts from a wild-type strain. Methylmethane sulfonate (MMS)-resistant transformants were obtained on medium containing 0.01% MMS, to which uvsH mutants exhibit high sensitivity. Retransformation of uvsH77 mutants with the rescued cosmids from the MMS-resistant transformants resulted in restoration of both UV and MMS resistance to wild-type levels. Nucleotide sequence analysis of the genomic DNA and cDNA of the uvsH gene shows that it has an open reading frame (ORF) of 1329 bp, interrupted by two introns of 51 and 61 bp. A 2.4 kb transcript of the uvsH gene was detected by Northern blot analysis. Primer extension analysis revealed that transcription starts at 31 bp upstream from the translation initiation codon. This gene encodes a predicted polypeptide of 443 amino acids, which has two unique zinc finger motifs. The proposed polypeptide displays 39% identity to the Neurospora crassa UVS-2 protein and 24% identity to the Saccharomyces cerevisiae RAD18 protein. The sequence similarity is particularly high in three domains. One zinc finger (RING finger) motif is located in the first domain close to the N-terminus. The other zinc finger motif is in the second domain. In the third domain, the mutation sites in both the uvsH77 and uvsH304 alleles were identified.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Ultrasensitive, simple and solvent-free micro-assay for determining sulphite preservatives (E220-228) in foods by HS-SDME and UV-vis micro-spectrophotometry.

    Science.gov (United States)

    Gómez-Otero, E; Costas, M; Lavilla, I; Bendicho, C

    2014-03-01

    A new method based on headspace single-drop microextraction in combination with UV-vis micro-spectrophotometry has been developed for the ultrasensitive determination of banned sulphite preservatives (E220-228) in fruits and vegetables. Sample acidification was used for SO2 generation, which is collected onto a 5,5'-dithiobis-(2-nitrobenzoic acid) microdrop for spectrophotometric measurement. A careful study of this reaction was necessary, including conditions for SO2 generation from different sulphating salts, drop pH, 5,5'-dithiobis-(2-nitrobenzoic acid) concentration and potential interference effects. Variables influencing mass transfer (stirring, sample volume and addition of salt) and microextraction time were also studied. A simple sulphite extraction was carried out, and problems caused by oxidation during the extraction process were addressed. A high enrichment factor (380) allows the determination of low levels of free SO2 in fruits and vegetables (limit of detection 0.06 μg g(-1), limit of quantification 0.2 μg g(-1)) with an adequate precision (repeatability, relative standard deviation 5 %). In addition, the sulphiting process was studied through the monitoring of residual SO2 in a vegetal sample, thus showing the importance of a sensitive tool for SO2 detection at low levels.

  12. The response of human skin commensal bacteria as a reflection of UV radiation: UV-B decreases porphyrin production.

    Directory of Open Access Journals (Sweden)

    Yanhan Wang

    Full Text Available Recent global radiation fears reflect the urgent need for a new modality that can simply determine if people are in a radiation risk of developing cancer and other illnesses. Ultraviolet (UV radiation has been thought to be the major risk factor for most skin cancers. Although various biomarkers derived from the responses of human cells have been revealed, detection of these biomarkers is cumbersome, probably requires taking live human tissues, and varies significantly depending on human immune status. Here we hypothesize that the reaction of Propionibacterium acnes (P. acnes, a human resident skin commensal, to UV radiation can serve as early surrogate markers for radiation risk because the bacteria are immediately responsive to radiation. In addition, the bacteria can be readily accessible and exposed to the same field of radiation as human body. To test our hypothesis, P. acnes was exposed to UV-B radiation. The production of porphyrins in P. acnes was significantly reduced with increasing doses of UV-B. The porphyrin reduction can be detected in both P. acnes and human skin bacterial isolates. Exposure of UV-B to P. acnes- inoculated mice led to a significant decrease in porphyrin production in a single colony of P. acnes and simultaneously induced the formation of cyclobutane pyrimidine dimers (CPD in the epidermal layers of mouse skin. Mass spectrometric analysis via a linear trap quadrupole (LTQ-Orbitrap XL showed that five peptides including an internal peptide (THLPTGIVVSCQNER of a peptide chain release factor 2 (RF2 were oxidized by UV-B. Seven peptides including three internal peptides of 60 kDa chaperonin 1 were de-oxidized by UV-B. When compared to UV-B, gamma radiation also decreased the porphyrin production of P. acnes in a dose-dependent manner, but induced a different signature of protein oxidation/de-oxidation. We highlight that uncovering response of skin microbiome to radiation will facilitate the development of pre

  13. The response of human skin commensal bacteria as a reflection of UV radiation: UV-B decreases porphyrin production.

    Science.gov (United States)

    Wang, Yanhan; Zhu, Wenhong; Shu, Muya; Jiang, Yong; Gallo, Richard L; Liu, Yu-Tsueng; Huang, Chun-Ming

    2012-01-01

    Recent global radiation fears reflect the urgent need for a new modality that can simply determine if people are in a radiation risk of developing cancer and other illnesses. Ultraviolet (UV) radiation has been thought to be the major risk factor for most skin cancers. Although various biomarkers derived from the responses of human cells have been revealed, detection of these biomarkers is cumbersome, probably requires taking live human tissues, and varies significantly depending on human immune status. Here we hypothesize that the reaction of Propionibacterium acnes (P. acnes), a human resident skin commensal, to UV radiation can serve as early surrogate markers for radiation risk because the bacteria are immediately responsive to radiation. In addition, the bacteria can be readily accessible and exposed to the same field of radiation as human body. To test our hypothesis, P. acnes was exposed to UV-B radiation. The production of porphyrins in P. acnes was significantly reduced with increasing doses of UV-B. The porphyrin reduction can be detected in both P. acnes and human skin bacterial isolates. Exposure of UV-B to P. acnes- inoculated mice led to a significant decrease in porphyrin production in a single colony of P. acnes and simultaneously induced the formation of cyclobutane pyrimidine dimers (CPD) in the epidermal layers of mouse skin. Mass spectrometric analysis via a linear trap quadrupole (LTQ)-Orbitrap XL showed that five peptides including an internal peptide (THLPTGIVVSCQNER) of a peptide chain release factor 2 (RF2) were oxidized by UV-B. Seven peptides including three internal peptides of 60 kDa chaperonin 1 were de-oxidized by UV-B. When compared to UV-B, gamma radiation also decreased the porphyrin production of P. acnes in a dose-dependent manner, but induced a different signature of protein oxidation/de-oxidation. We highlight that uncovering response of skin microbiome to radiation will facilitate the development of pre-symptomatic diagnosis

  14. Determination of ammonium in river water and sewage samples by capillary zone electrophoresis with direct UV detection.

    Science.gov (United States)

    Fukushi, Keiichi; Ito, Hideyuki; Kimura, Kenichi; Yokota, Kuriko; Saito, Keiitsu; Chayama, Kenji; Takeda, Sahori; Wakida, Shin-ichi

    2006-02-17

    We developed capillary zone electrophoresis (CZE) with direct UV detection for determination of ammonium in environmental water samples. Ammonium in the samples was partly converted into ammonia in the alkaline background electrolyte (BGE) during migration and was detected by molecular absorption of ammonia at 190 nm in approximately 7 min. The limit of detection (LOD) for ammonium was 0.24 mg/l (as nitrogen) at a signal-to-noise ratio of three. The respective values of the relative standard deviation (RSD) of peak area, peak height, and migration time for ammonium were 2.1, 1.8, and 0.46%. Major alkali and alkaline earth metal ions coexisting in the samples did not interfere with ammonium determination by the proposed method. The proposed method determined ammonium in surface water and sewage samples. The results were compared to those obtained using ion chromatography (IC).

  15. 340nm UV LED excitation in time-resolved fluorescence system for europium-based immunoassays detection

    Science.gov (United States)

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2017-02-01

    In immunoassay analyzers for in-vitro diagnostics, Xenon flash lamps have been widely used as excitation light sources. Recent advancements in UV LED technology and its advantages over the flash lamps such as smaller footprint, better wall-plug efficiency, narrow emission spectrum, and no significant afterglow, have made them attractive light sources for gated detection systems. In this paper, we report on the implementation of a 340 nm UV LED based time-resolved fluorescence system based on europium chelate as a fluorescent marker. The system performance was tested with the immunoassay based on the cardiac marker, TnI. The same signal-to-noise ratio as for the flash lamp based system was obtained, operating the LED below specified maximum current. The background counts of the system and its main contributors were measured and analyzed. The background of the system of the LED based unit was improved by 39% compared to that of the Xenon flash lamp based unit, due to the LEDs narrower emission spectrum and longer pulse width. Key parameters of the LED system are discussed to further optimize the signal-to-noise ratio and signal-to-background, and hence the sensitivity of the instrument.

  16. Eliminating amino acid interference during spectrophotometric NH4+ analysis

    NARCIS (Netherlands)

    Ros, G.H.; Leeuwen, van A.G.; Temminghoff, E.J.M.

    2011-01-01

    Amino acids can interfere with NH4+ in spectrophotometric NH4+ determination hampering accurate quantification of the fate of NH4+ and dissolved organic N in soils. Serious interference has been reported for soils rich in organic matter, and for soils that have been fumigated, oven-dried or

  17. Comparison of spectrophotometric and radioisotopic methods for the assay of Rubisco in ozone-treated plants

    International Nuclear Information System (INIS)

    Reid, C.D.; Tissue, D.T.; Fiscus, E.L.; Strain, B.R.

    1997-01-01

    Radioisotopic and spectrophotometric assays for ribulose-1,5-bisphosphate carboxylase/oxygenase (Rubisco) initial and final activities and Rubisco content were compared in plants chronically exposed to ozone (O 3 ) in a greenhouse and the field. In a greenhouse experiment, Glycine max was treated in exposure chambers with either charcoal-filtered air (CF air) or 100 nl O 3 l -1 for 6 h daily during vegetative growth. Samples were collected after 7 days of exposure. In a field experiment, G. max was treated in open-top chambers with either CF air or non-filtered air with O 3 added at 1.5 times ambient O 3 for 12 h daily. Average daily O 3 concentrations were 21 and 92 nl l -1 in the CF and O 3 treatments, respectively. Samples were collected during vegetative and reproductive growth. Both assays generally yielded comparable Rubisco initial and final activities for greenhouse-grown plants regardless of the O 3 treatment. However for field-grown plants, Rubisco initial and final activities average 15 and 23% lower when assayed by the spectrophotometric rather than the radioisotopic method. For Rubisco content estimated by the spectrophotometric method, lower values for the regression of Rubisco activity vs concentration of carboxyarabinitol-1.5-bisphosphate were observed in O 3- than in CF-treated plants. Both assays yielded comparable Rubisco contents in the greenhouse and in the field although the variation was larger with the spectrophotometric method in field-grown plants. Growth conditions, field vs greenhouse, were more critical to the spectrophotometric assay performance than the O 3 treatments for measurement of Rubisco activity and content. (au) 40 refs

  18. Application of different spectrophotometric methods for simultaneous determination of elbasvir and grazoprevir in pharmaceutical preparation

    Science.gov (United States)

    Attia, Khalid A. M.; El-Abasawi, Nasr M.; El-Olemy, Ahmed; Abdelazim, Ahmed H.

    2018-01-01

    The first three UV spectrophotometric methods have been developed of simultaneous determination of two new FDA approved drugs namely; elbasvir and grazoprevir in their combined pharmaceutical dosage form. These methods include simultaneous equation, partial least squares with and without variable selection procedure (genetic algorithm). For simultaneous equation method, the absorbance values at 369 (λmax of elbasvir) and 253 nm (λmax of grazoprevir) have been selected for the formation of two simultaneous equations required for the mathematical processing and quantitative analysis of the studied drugs. Alternatively, the partial least squares with and without variable selection procedure (genetic algorithm) have been applied in the spectra analysis because the synchronous inclusion of many unreal wavelengths rather than by using a single or dual wavelength which greatly increases the precision and predictive ability of the methods. Successfully assay of the drugs in their pharmaceutical formulation has been done by the proposed methods. Statistically comparative analysis for the obtained results with the manufacturing methods has been performed. It is noteworthy to mention that there was no significant difference between the proposed methods and the manufacturing one with respect to the validation parameters.

  19. Covalent bindings in proteins following UV-C irradiation

    International Nuclear Information System (INIS)

    Diezel, W.; Meffert, H.; Soennichsen, N.; Reinicke, C.

    1980-01-01

    Following a UV-C irradiation of catalase cross-linked catalase subunits could be detected by sodium dodecylsulfate gel electrophoresis. The subunits of aldolase were not cross-linked. The origin of covalent bindings in the catalase molecule is suggested to be effected by a free radical chain reaction induced by the heme component of catalase after UV-C irradiation. (author)

  20. Spectrophotometric determination of aluminium in steel with xylenol orange

    International Nuclear Information System (INIS)

    Majeed, A.; Javed, N.; Khan, M.S.

    1996-01-01

    Spectrophotometric determination of Aluminium in steel based on colour reaction between Aluminium and xylenol orange has been carried out. Red coloured complex formed in weak acidic solution is measured for its absorbance at 550 nm. The various optimum experimental conditions for Aluminium xylenol orange (Al-Xo) complex have been studied. (author)

  1. Spectrophotometrical investigation of the NGC 3359 galaxy

    International Nuclear Information System (INIS)

    Burenkov, A.N.; Khchikyan, Eh.E.; AN Armyanskoj SSR, Byurakan. Astrofizicheskaya Observatoriya)

    1986-01-01

    Results of detailed spectrophotometrical investigations of NGC 3353, carried out with 6 m telescope of SAO Academy of Sciences of the USSR are presented (dispersion approximately 65 A/mm). Four separate condensations, the brightest of which is Mark 35, are studied. In the spectrum of Mark 35 the emission lines for Hsub(α) to H 12 , HeI lambda lambda 7065, 6678, 5876, 4922, 4472, 3820 and forbidden lines [01]lambda lambdas 6300/64, [02] lambda 3727, [03] lambda lambda 5007, 4959, 4363, [Ne3] lambda 3869, [N2] lambda lambda 6584/48, [S2] lambda lambda 6717/31, [S3] lambda 6310, [Ar3] lambda 7136 are detected. In the second central condensation, called ''nucleus'', emission lines are weaker and beginning with Hsub(β) the absorption components appear which become stronger in the late members of Balmer lines. The forbidden lines in the nucleus are strong: [Ne3], [O3], [O2], [S2][N2]. The relative intensities and equivalent widths of emission lines as well as the chemical composition of Mark 35 and ''nucleus'' are estimated. Both condensations according to their physical properties look like superassociations. It has been concluded that the source of excitation are young stars. NGC 3353 is probably the net of superassociations

  2. CUVE - Cubesat UV Experiment: Unveil Venus' UV Absorber with Cubesat UV Mapping Spectrometer

    Science.gov (United States)

    Cottini, V.; Aslam, S.; D'Aversa, E.; Glaze, L.; Gorius, N.; Hewagama, T.; Ignatiev, N.; Piccioni, G.

    2017-09-01

    Our Venus mission concept Cubesat UV Experiment (CUVE) is one of ten proposals selected for funding by the NASA PSDS3 Program - Planetary Science Deep Space SmallSat Studies. CUVE concept is to insert a CubeSat spacecraft into a Venusian orbit and perform remote sensing of the UV spectral region using a high spectral resolution point spectrometer to resolve UV molecular bands, observe nightglow, and characterize the unidentified main UV absorber. The UV spectrometer is complemented by an imaging UV camera with multiple bands in the UV absorber main band range for contextual imaging. CUVE Science Objectives are: the nature of the "Unknown" UV-absorber; the abundances and distributions of SO2 and SO at and above Venus's cloud tops and their correlation with the UV absorber; the atmospheric dynamics at the cloud tops, structure of upper clouds and wind measurements from cloud-tracking; the nightglow emissions: NO, CO, O2. This mission will therefore be an excellent platform to study Venus' cloud top atmospheric properties where the UV absorption drives the planet's energy balance. CUVE would complement past, current and future Venus missions with conventional spacecraft, and address critical science questions cost effectively.

  3. THE SPECTROPHOTOMETRIC DETERMINATION OF NITRITES WITH N,N-DIETHYLANILINE

    Directory of Open Access Journals (Sweden)

    O. S. Pogrebnyak

    2015-11-01

    Full Text Available A new spectrophotometric method for nitrite determination was proposed. The method is based on the measurement of absorbance of the N,N-diethylaniline nitrosation product at 475 nm in the hydrochloric acid medium. The optimum concentrations and the influence of various conditions on the determination sensitivity have been determined. The detection limit (blank + 3s for nitrite is 0.98 mg∙L–1 where sis the standard deviation of blank estimation. The linearity range of the calibration graph was over 1.0–100 mg∙L–1 of  nitrite (sr≤ 0.029, n = 8. The metrological characteristics of the procedure were checked by means of method of additives on the control samples and natural waters. The relative error did not exceed 0.06 for nitrite determination on the control samples. The effect of foreign ions in nitrite determination of 1,0∙10−3 mol∙L–1 has been studied. The proposed procedure is simple  and suitable for nitrite determination in various objects.

  4. uvsI mutants defective in UV mutagenesis define a fourth epistatic group of uvs genes in Aspergillus.

    Science.gov (United States)

    Chae, S K; Kafer, E

    1993-01-01

    Three UV-sensitive mutations of A. nidulans, uvsI, uvsJ and uvsA, were tested for epistatic relationships with members of the previously established groups, here called the "UvsF", "UvsC", and "UvsB" groups. uvsI mutants are defective for spontaneous and induced reversion of certain point mutations and differ also for other properties from previously analyzed uvs types. They are very sensitive to the killing effects of UV-light and 4-NQO (4-nitro-quinoline-N-oxide) but not to MMS (methylmethane sulfonate). When double- and single-mutant uvs strains were compared for sensitivity to these three agents, synergistic or additive effects were found for uvsI with all members of the three groups. The uvsI gene may therefore represent a fourth epistatic group, possibly involved in mutagenic repair. On the other hand, uvsJ was clearly epistatic with members of the UvsF group and fitted well into this group also by phenotype. The uvsA gene was tentatively assigned to the UvsC group. uvsA showed epistatic interactions with uvsC in all tests, and like UvsC-group mutants is UV-sensitive mainly in dividing cells. However, the uvsA mutation does not cause the defects in recombination and UV mutagenesis typical for this group.

  5. AlN ceramics as a detector for UV exposure

    International Nuclear Information System (INIS)

    Trinkler, L.; Berzina, B.; Boetter-Jensen, L.; Christensen, P.; Palcevskis, E.

    1999-01-01

    AlN-Y 2 O 3 ceramics is proposed for application in the field of UV detection and dosimetry. Both thermoluminescence (TL) and optically stimulated luminescence (OSL) signals from the material have been studied after exposure to UV light. AlN-Y 2 O 3 ceramics demonstrates very high sensitivity to UV light over a broad spectral region. The TL is characterized by a linear dose dependence over a large range. The fading rate of the UV-induced TL and OSL signals on storage at room temperature is lower than in the case of exposure to ionizing irradiation. (au)

  6. Analysis of biologically active oxyprenylated phenylpropanoids in Tea tree oil using selective solid-phase extraction with UHPLC-PDA detection.

    Science.gov (United States)

    Scotti, Luca; Genovese, Salvatore; Bucciarelli, Tonino; Martini, Filippo; Epifano, Francesco; Fiorito, Serena; Preziuso, Francesca; Taddeo, Vito Alessandro

    2018-05-30

    An efficient analytical strategy based on different extraction methods of biologically active naturally occurring oxyprenylated umbelliferone and ferulic acid derivatives 7-isopentenyloxycoumarin, auraptene, umbelliprenin, boropinic acid, and 4'-geranyloxyferulic acid and quantification by UHPLC with spectrophotometric (UV/Vis) detection from Tea tree oil is reported. Absorption of the pure oil on Al 2 O 3 (Brockmann activity II) prior washing the resulting solid with MeOH and treatment of this latter with CH 2 Cl 2 resulted the best extraction methodology in terms of yields of oxyprenylated secondary metabolites. Among the five O-prenylphenylpropanoids herein under investigation auraptene and umbelliprenin were never detected while 4'-geranyloxyferulic acid was the most abundant compound resulting from all the three extraction methods employed. The UHPLC analytical methodology set up in the present study resulted to be an effective and versatile technique for the simultaneous characterization and quantification of prenyloxyphenylpropanoids in Tea tree oil and applicable to other complex matrices from the plant kingdom. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. The research on a novel type of the solar-blind UV head-mounted displays

    Science.gov (United States)

    Zhao, Shun-long

    2011-08-01

    Ultraviolet technology of detecting is playing a more and more important role in the field of civil application, especially in the corona discharge detection, in modern society. Now the UV imaging detector is one of the most important equipments in power equipment flaws detection. And the modern head-mounted displays (HMDs) have shown the applications in the fields of military, industry production, medical treatment, entertainment, 3D visualization, education and training. We applied the system of head-mounted displays to the UV image detection, and a novel type of head-mounted displays is presented: the solar-blind UV head-mounted displays. And the structure is given. By the solar-blind UV head-mounted displays, a real-time, isometric and visible image of the corona discharge is correctly displayed upon the background scene where it exists. The user will see the visible image of the corona discharge on the real scene rather than on a small screen. Then the user can easily find out the power equipment flaws and repair them. Compared with the traditional UV imaging detector, the introducing of the HMDs simplifies the structure of the whole system. The original visible spectrum optical system is replaced by the eye in the solar-blind UV head-mounted displays. And the optical image fusion technology would be used rather than the digital image fusion system which is necessary in traditional UV imaging detector. That means the visible spectrum optical system and digital image fusion system are not necessary. This makes the whole system cheaper than the traditional UV imaging detector. Another advantage of the solar-blind UV head-mounted displays is that the two hands of user will be free. So while observing the corona discharge the user can do some things about it. Therefore the solar-blind UV head-mounted displays can make the corona discharge expose itself to the user in a better way, and it will play an important role in corona detection in the future.

  8. Degradation of Organic UV filters in Chlorinated Seawater Swimming Pools: Transformation Pathways and Bromoform Formation.

    Science.gov (United States)

    Manasfi, Tarek; Coulomb, Bruno; Ravier, Sylvain; Boudenne, Jean-Luc

    2017-12-05

    Organic ultraviolet (UV) filters are used in sunscreens and other personal-care products to protect against harmful effects of exposure to UV solar radiation. Little is known about the fate of UV filters in seawater swimming pools disinfected with chlorine. The present study investigated the occurrence and fate of five commonly used organic UV filters, namely dioxybenzone, oxybenzone, avobenzone, 2-ethylhexyl-4-methoxycinnamate, and octocrylene, in chlorinated seawater swimming pools. Pool samples were collected to monitor the variation of UV filter concentrations during pool opening hours. Furthermore, laboratory-controlled chlorination experiments were conducted in seawater spiked with UV filters to investigate the reactivity of UV filters. Extracts of chlorination reaction samples were analyzed using high-resolution mass spectrometry and electron-capture detection to identify the potentially formed byproducts. In the collected pool samples, all the UV filters except dioxybenzone were detected. Chlorination reactions showed that only octocrylene was stable in chlorinated seawater. The four reactive UV filters generated brominated transformation products and disinfection byproducts. This formation of brominated products resulted from reactions between the reactive UV filters and bromine, which is formed rapidly when chlorine is added to seawater. Based on the identified byproducts, the transformation pathways of the reactive UV filters were proposed for the first time. Bromoform was generated by all the reactive UV filters at different yields. Bromal hydrate was also detected as one of the byproducts generated by oxybenzone and dioxybenzone.

  9. Monoclonal antibodies reactive with common tumor antigens on UV-induced tumors also react with hyperplastic UV-irradiated skin

    International Nuclear Information System (INIS)

    Spellman, C.W.; Beauchamp, D.A.

    1986-01-01

    Most murine skin tumors induced by ultraviolet light (UVB, 280-340 nm) can be successfully transplanted only into syngeneic hosts that have received subcarcinogenic doses of UVB. The tumor susceptible state is long-lived and mediated by T suppressor cells that control effector responses against common antigens on UV-induced tumors. Because antigen specific suppression arises prior to the appearance of a tumor, questions arise about the source of the original antigen. They have previously reported transplantation studies indicating that UV-irradiated skin is antigenically cross-reactive with UV-induced tumors. They now report on flow cytometry analyses showing that a series of MoAb reactive with common antigens expressed by UV-induced tumors are also reactive on cells from UV-irradiated skin. Various antigens appear at different times in the UV irradiation scheme, and some persist while others are transient. They speculate that the common antigens detected may be the ones to which functional suppression is directed. If true, these results suggest that successful tumors need not escape host defenses to emerge. Rather, tumors may arise and grow progressively if they express antigens that cross-react with specificities to which the host has previously mounted a suppressive response

  10. Kinetic Spectrophotometric Determination of Certain Cephalosporins in Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    Mahmoud A. Omar

    2009-01-01

    Full Text Available A simple, reliable, and sensitive kinetic spectrophotometric method was developed for determination of eight cephalosporin antibiotics, namely, Cefotaxime sodium, Cephapirin sodium, Cephradine dihydrate, Cephalexin monohydrate, Ceftazidime pentahydrate, Cefazoline sodium, Ceftriaxone sodium, and Cefuroxime sodium. The method depends on oxidation of each of studied drugs with alkaline potassium permanganate. The reaction is followed spectrophotometrically by measuring the rate of change of absorbance at 610 nm. The initial rate and fixed time (at 3 minutes methods are utilized for construction of calibration graphs to determine the concentration of the studied drugs. The calibration graphs are linear in the concentration ranges 5–15 g mL−1 and 5–25 g mL−1 using the initial rate and fixed time methods, respectively. The results are validated statistically and checked through recovery studies. The method has been successfully applied for the determination of the studied cephalosporins in commercial dosage forms. Statistical comparisons of the results with the reference methods show the excellent agreement and indicate no significant difference in accuracy and precision.

  11. Removal of binary azo dyes from water by UV-irradiated degradation in TiO2 suspensions

    International Nuclear Information System (INIS)

    Juang, Ruey-Shin; Lin, Su-Hsia; Hsueh, Pei-Ying

    2010-01-01

    Photodegradation and mineralization of single and binary Acid Orange 7 (AO7) and Reactive Red 2 (RR2) under UV irradiation in TiO 2 suspensions was examined. Experiments were conducted as a function of initial pH, TiO 2 dose, and initial dye concentration. First-order derivative spectrophotometric method was used to simultaneously analyze AO7 and RR2 in binary solutions. The Langmuir-Hinshelwood kinetic model was applied to evaluate and compare the apparent rate constants for the photodegradation of both dyes in single and binary solutions. It was shown that photodegradation of both dyes in binary solution was slower than those in single solution under comparable conditions. Moreover, the difference between the apparent rate constants of RR2 and AO7 became smaller in contrast to the cases of single solutions. After 20-min UV irradiation with 0.5 g/L TiO 2 , complete removal of single 0.086 mM AO7 and 0.086 mM RR2 at pH 6.8 was obtained, but only 60% and 45% of binary 0.086 mM AO7 and 0.086 mM RR2 was removed, respectively.

  12. Environmental occurrence and distribution of organic UV stabilizers and UV filters in the sediment of Chinese Bohai and Yellow Seas.

    Science.gov (United States)

    Apel, Christina; Tang, Jianhui; Ebinghaus, Ralf

    2018-04-01

    Organic UV stabilizers and UV filters are applied to industrial materials and cosmetics worldwide. In plastics they prevent photo-induced degradation, while in cosmetics they protect human skin against harmful effects of UV radiation. This study reports on the occurrence and distribution of organic UV stabilizers and UV filters in the surface sediment of the Chinese Bohai and Yellow Seas for the first time. In total, 16 out of 21 analyzed substances were positively detected. Concentrations ranged from sub-ng/g dw to low ng/g dw. The highest concentration of 25 ng/g dw was found for octocrylene (OC) in the Laizhou Bay. In the study area, characteristic composition profiles could be identified. In Korea Bay, the dominating substances were OC and ethylhexyl salicylate (EHS). All other analytes were below their method quantification limit (MQL). Around the Shandong Peninsula, highest concentrations of benzotriazole derivatives were observed in this study with octrizole (UV-329) as the predominant compound, reaching concentrations of 6.09 ng/g dw. The distribution pattern of UV-329 and bumetrizole (UV-326) were related (Pearson correlation coefficient r > 0.98, p « 0.01 around the Shandong Peninsula), indicating an identical input pathway and similar environmental behavior. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Extraction-spectrophotometric method for silicon determination in high-purity substances. 2. Silicon determination in cadmium

    Energy Technology Data Exchange (ETDEWEB)

    Yudelevich, I G; Shaburova, V P; Shamrina, L V [AN SSSR, Novosibirsk (USSR). Inst. Neorganicheskoj Khimii

    1989-01-01

    Cadmium extraction by tributyl phosphate and trialkylbenzylammonium chloride (TABAC) depending on acid (HCl, HI), extracting agent concentration, volume of aqueous and organic phases, number of extraction steps is investigated. On the basis of the obtained results the spectrophotometric method for silicon determination in cadmium and CdCl/sub 2/ using malachite green with preliminary extraction of the base by the TABAC from HCl solutions. The method detection limit is 3.9x10/sup -4/ % Si with respect to initial cadmium sample of 100 mg and 7.8x10/sup -5/ % with respect to 0.5 g of CdCl/sub 2/. The relative standard deviation is S/sub r/-0.07-0.13.

  14. Spectrophotometric Determination of Iron(II and Cobalt(II by Direct, Derivative, and Simultaneous Methods Using 2-Hydroxy-1-Naphthaldehyde-p-Hydroxybenzoichydrazone

    Directory of Open Access Journals (Sweden)

    V. S. Anusuya Devi

    2012-01-01

    Full Text Available Optimized and validated spectrophotometric methods have been proposed for the determination of iron and cobalt individually and simultaneously. 2-hydroxy-1-naphthaldehyde-p-hydroxybenzoichydrazone (HNAHBH reacts with iron(II and cobalt(II to form reddish-brown and yellow-coloured [Fe(II-HNAHBH] and [Co(II-HNAHBH] complexes, respectively. The maximum absorbance of these complexes was found at 405 nm and 425 nm, respectively. For [Fe(II-HNAHBH], Beer’s law is obeyed over the concentration range of 0.055–1.373 μg mL−1 with a detection limit of 0.095 μg mL−1 and molar absorptivity ɛ, 5.6 × 104 L mol−1 cm−1. [Co(II-HNAHBH] complex obeys Beer’s law in 0.118–3.534 μg mL−1 range with a detection limit of 0.04 μg mL−1 and molar absorptivity, ɛ of 2.3 × 104 L mol−1 cm−1. Highly sensitive and selective first-, second- and third-order derivative methods are described for the determination of iron and cobalt. A simultaneous second-order derivative spectrophotometric method is proposed for the determination of these metals. All the proposed methods are successfully employed in the analysis of various biological, water, and alloy samples for the determination of iron and cobalt content.

  15. Spectrophotometric method for the determination of thorium in UO2 pellets

    International Nuclear Information System (INIS)

    Acosta L, E.

    1995-04-01

    This report presents a procedure with the description of the spectrophotometric method for the determination of the thorium element in uranium products including powders and pellets of uranium dioxide. Quantities can be determined starting from 1 ppm. (Author)

  16. A Method Based on Ultrasound-assisted Solidification of Floating Drop Microextraction Technique for the Spectrophotometric Determination of Curcumin in Turmeric Powder

    Directory of Open Access Journals (Sweden)

    Abbas Afkhami

    2017-06-01

    Full Text Available A method based on the ultrasound-assisted solidification of floating drop microextraction technique was developed for the spectrophotometric and spectrofluorimetric determination of curcumin in turmeric powder. In this work a small volume of an organic solvent was floated on the surface of an aqueous solution. After sonication the organic solvent is solidified and separated. The effect of extraction parameters such as type and the volume of organic solvent, temperature, salt addition and exposure time, on the extraction recovery was investigated and optimized. Finally, the method droplet was used for the determination of analyte. Under the optimum extraction conditions, a linear range of 0.006–30 μg mL-1 and a relative standard deviation (RSD of 2.72% for curcumin wasachieved. Limits of detection of 7 and 2 ng mL-1 curcumin was obtained for the spectrophotometric and spectrofluometric methods, respectively. The obtained results show that the application of this method can be successful for the analysis of curcumin in turmeric powder samples.

  17. UV Observations of Atomic Oxygen in the Cusp Region

    Science.gov (United States)

    Fritz, B.; Lessard, M.; Dymond, K.; Kenward, D. R.; Lynch, K. A.; Clemmons, J. H.; Hecht, J. H.; Hysell, D. L.; Crowley, G.

    2017-12-01

    The Rocket Experiment for Neutral Upwelling (RENU) 2 launched into the dayside cusp on 13 December, 2015. The sounding rocket payload carried a comprehensive suite of particle, field, and remote sensing instruments to characterize the thermosphere in a region where pockets of enhanced neutral density have been detected [Lühr et al, 2004]. An ultraviolet photomultiplier tube (UV PMT) was oriented to look along the magnetic field line and remotely detect neutral atomic oxygen (OI) above the payload. The UV PMT measured a clear enhancement as the payload descended through a poleward moving auroral form, an indicator of structure in both altitude and latitude. Context for the UV PMT measurement is provided by the Special Sensor Ultraviolet Imager (SSULI) instrument on the Defense Meteorological Space Program (DMSP) satellite, which also measured OI as it passed through the cusp. UV tomography of SSULI observations produces a two-dimensional cross-section of volumetric emission rates in the high-latitude thermosphere prior to the RENU 2 flight. The volume emission rate may then be inverted to produce a profile of neutral density in the thermosphere. A similar technique is used to interpret the UV PMT measurement and determine structure in the thermosphere as RENU 2 descended through the cusp.

  18. Spectrophotometric determination of metals in Pakistani and foreign brand cigarette tobacco

    International Nuclear Information System (INIS)

    Ikram, M.; Rauf, M.A.; Ali, S.; Iqbal, M.

    2001-01-01

    Tobacco smoking and related uses are major cause of various diseases in human beings. In the present study forty one various brands of cigarettes from Pakistan, United States, United Kingdom and Japan have been selected for determination of iron, nickel and copper spectrophotometrically. The concentration of Fe, Ni and Cu in tobacco of each forty-one brands of national and foreign brands cigarette is given in this article. The spectrophotometric determination of Fe, Ni and Cu in forty one brands of national and foreign cigarettes reveals that the concentrations of these metals depends on different conditions, such as soil condition, fertilizer and sprays during the tobacco growth. However, Cigarette manufacturing companies could have a significant role in their concentration levels. The results obtained by this technique are in good agreement with the reported literature values. (A.B.)

  19. Single Photon Counting UV Solar-Blind Detectors Using Silicon and III-Nitride Materials

    Science.gov (United States)

    Nikzad, Shouleh; Hoenk, Michael; Jewell, April D.; Hennessy, John J.; Carver, Alexander G.; Jones, Todd J.; Goodsall, Timothy M.; Hamden, Erika T.; Suvarna, Puneet; Bulmer, J.; Shahedipour-Sandvik, F.; Charbon, Edoardo; Padmanabhan, Preethi; Hancock, Bruce; Bell, L. Douglas

    2016-01-01

    Ultraviolet (UV) studies in astronomy, cosmology, planetary studies, biological and medical applications often require precision detection of faint objects and in many cases require photon-counting detection. We present an overview of two approaches for achieving photon counting in the UV. The first approach involves UV enhancement of photon-counting silicon detectors, including electron multiplying charge-coupled devices and avalanche photodiodes. The approach used here employs molecular beam epitaxy for delta doping and superlattice doping for surface passivation and high UV quantum efficiency. Additional UV enhancements include antireflection (AR) and solar-blind UV bandpass coatings prepared by atomic layer deposition. Quantum efficiency (QE) measurements show QE > 50% in the 100–300 nm range for detectors with simple AR coatings, and QE ≅ 80% at ~206 nm has been shown when more complex AR coatings are used. The second approach is based on avalanche photodiodes in III-nitride materials with high QE and intrinsic solar blindness. PMID:27338399

  20. UV Deprivation Influences Social UV Preference in Juvenile Sticklebacks

    Directory of Open Access Journals (Sweden)

    Ricarda Modarressie

    2015-05-01

    Full Text Available Social aggregations occur in many different animal taxa and mainly result from non-random assortment. Investigating factors that shape and maintain the composition of social aggregations are among others a main topic for understanding ecological speciation processes. Aggregation decisions are mediated by olfactory and visual cues, which in many animals are extended into the UV part of the electromagnetic spectrum. Here, we were interested in developmental plasticity of social preferences with respect to UV radiation in aquatic organisms. Specifically, we tested whether different lighting environments with respect to UV wavelengths during early life stages influence the shoaling preference in juvenile threespine sticklebacks (Gasterosteus aculeatus. Family (full-sibling groups were split and reared under UV-lacking (UV- and UV-present (UV+ lighting conditions. Subsequent shoal choice experiments, in which test fish from both rearing conditions could simultaneously choose between a shoal seen behind a UV-blocking (UV- and a shoal seen behind a UV-transmitting (UV+ filter, revealed a significant effect of lighting condition during rearing on association preference. Test fish that had been deprived of UV spent significantly more time near the UV- shoal compared to the test fish reared under full-spectrum lighting conditions. The results are discussed with respect to plasticity of the visual system and environmental lighting conditions.

  1. Simultaneous determination of ammonia, dimethylamine, trimethylamine and trimethylamine-N-oxide in fish extracts by capillary electrophoresis with indirect UV-detection

    DEFF Research Database (Denmark)

    Timm Heinrich, Maike; Jørgensen, Bo

    2002-01-01

    A capillary electrophoretic method with indirect UV detection is described for simultaneous determination of ammonia, dimethylamine (DMA), trimethylamine (TMA) and trimethylamine-N- oxide (TMAO) in aqueous extracts of fish, A buffer consisting of 4 mM formic acid, 5 mM copper(II)sulfate and 3 m......M. The detection limit for ammonia, DMA, TMA, and TMAO was less than 0.04 mM, corresponding to 2 mg nitrogen per 100 g fish. As an extra benefit, the method also provided a quantitative determination of potassium, sodium, calcium and magnesium ions. (C) 2002 Elsevier Science Ltd. All rights reserved....

  2. Spectrophotometric studies of transcurium element halides and oxyhalides in the solid state

    International Nuclear Information System (INIS)

    Young, J.P.; Haire, R.G.; Fellows, R. L.; Peterson, J.R.

    1978-01-01

    The present state of a microscale spectrophotometric technique is described. The application of spectrophotometry to transcurium elements (Bk, Cf, Es) requires some rather specialized microtechniques for the following reasons: only small amounts of these elements are available; their radioactivity makes the use of μg-sized samples desirable; and spectral study of solids requires thin samples. A schematic diagram of the microscope-spectrophotometer used for spectrophotometric study of the transcurium element compounds is shown. The spectrophotometer, of local design, consists of two microscopes equipped with Cassegrainian reflecting microscope objective lenses, a quartz field lens, and a Jarrell Ash 1/2 meter scanning monochromator equipped with a 1180 line/mm grating blazed at 4000 A. The photomultiplier used in this system is an S-1 type RCA 7102 operated at approximately -50 deg C. This grating-photomultiplier combination provides a continuous response free of discontinuities over the useful wavelength range of the system from 3000 to 11 000 A. The microscope-spectrophotometer is a single beam instrument. Each spectral trace is registered as photomultiplier current on a strip chart recorder. In order to obtain true absorption spectra, however, the output from the photometer is also simultaneously digitized for on-line processing. The unique advantages of applying both spectrophotometric and X-ray powder diffraction methods on the sample, in order to identify and characterize newly synthesized compounds, are also discussed. (T.G.)

  3. Determination of phenyl-N-methylcarbamates and their hydrolysis products in water, using solid-phase extraction and reversed-phase liquid chromatography with UV and electrospray mass spectrometric detection

    International Nuclear Information System (INIS)

    El Atrache, L.L.; Sabbah, S.

    2003-01-01

    In this study, eight phenyl-N-methylcarbamates (PNMCs) were considered. Reversed-phase LC was set up for UV and mass spectrometry (MS) detection mode. Gradient elution was used, and the mobile phase was composed of acetonitrile and water. UV-vis was performed at 220 nm. The method was tested with different reversed-phase columns. Comparison between chromatographic parameters: retention time (t R ), resolution (R S ), and selectivity (α) was established. Hydrolysis kinetics of three of the PNMCs were reported. The major hydrolysis products were determined by LC-UV, and the effect of pH on hydrolysis was also studied. Also, chromatographic separation of a mixture of PNMCs and four of their hydrolysis products was carried out. The preconcentration of 12 studied solutes was realized by solid-phase extraction. C18 extraction cartridges of 1 g were used to extract solutes from a 100 mL volume of tap and surface water spiked at 10 μg/L. The recoveries were, respectively, between 68-86% and 62-83% with relative a standard deviation of less than 11%. Limits of detection (LODs) and limits of quantitation (LOQs) ranged, respectively, from 1-4 μg/L and from 4-10 μg/L. Since standard UV detection does not provide adequate selectivity for water samples, an electrospray (ES)-MS instrument equipped with a triple quadrupole mass filter was used. MS data acquisition was performed by a time-scheduled, selected-ion monitoring (SIM) program. Limits of quantitation gave values between 0.1-0.5 μg/L. (author)

  4. Spectrophotometric determination of nicradipine and isradipine in pharmaceutical formulations

    Directory of Open Access Journals (Sweden)

    S. M. Al-Ghannam

    2009-05-01

    Full Text Available A sensitive spectrophotometric method was developed for the determination of some 1,4-dihydropyridine compounds namely, nicardipine and isradipine either in pure form or in pharmaceutical preparations. The method is based on the reduction of nicardipine and isradipine with zinc powder and calcium chloride followed by further reduction with sodium pentacyanoaminoferrate (II to give violet and red products having the absorbance maximum at 546 and 539 nm with nicardipine and isradipine, respectively. Beer’s law was obeyed over the concentration range 8.0–180 μg/ml with the detection limit of 1.67 μg/ml for nicardipine and 8.0–110 μg/ml with the detection limit of 1.748 μg/ml for isradipine. The analytical parameters and their effects on the reported methods were investigated. The molar absorptivity, quantization limit, standard deviation of intercept (Sa, standard deviation of slope (Sb and standard deviation of the residuals (Sy/x were calculated. The composition of the result compounds were found 1:1 for nicardipine and 1:2 for isradipine by Job’s method and the conditional stability constant (Kf and the free energy changes (ΔG were calculated for compounds formed. The proposed method was applied successfully for the determination of nicardipine and isradipine in their dosage forms. The results obtained were in good agreement with those obtained using the reference or official methods. A proposal of the reaction pathway was presented.

  5. Kinetic spectrophotometric method for the determination of perindopril erbumine in pure and commercial dosage forms

    Directory of Open Access Journals (Sweden)

    Nafisur Rahman

    2017-02-01

    Full Text Available A kinetic spectrophotometric method has been developed for the determination of perindopril erbumine in pure and commercial dosage forms. The method is based on the reaction of drug with potassium permanganate in alkaline medium at room temperature (30 ± 1 °C. The reaction was followed spectrophotometrically by measuring the increase in absorbance with time at 603 nm and the initial rate, fixed time (at 8.0 min and equilibrium time (at 90.0 min methods were adopted for constructing the calibration graphs. All the calibration graphs are linear in the concentration range of 5.0–50.0 μg/ml. The limits of detection for initial rate, fixed time and equilibrium time methods were 0.752, 0.882 and 1.091 μg/ml, respectively. The activation parameters such as Ea, ΔH‡, ΔS‡ and ΔG‡ were also determined for the reaction and found to be 60.93 kJ/mol, 56.45 kJ/mol, 74.16 J/K mol and −6.53 kJ/mol, respectively. The variables were optimized and the proposed methods are validated as per ICH guidelines. The method has been further applied to the determination of perindopril erbumine in commercial dosage forms. The analytical results of the proposed methods when compared with those of the reference method show no significant difference in accuracy and precision and have acceptable bias.

  6. Determination of benzodiazepines in beverages using green extraction methods and capillary HPLC-UV detection.

    Science.gov (United States)

    Piergiovanni, Maurizio; Cappiello, Achille; Famiglini, Giorgio; Termopoli, Veronica; Palma, Pierangela

    2018-05-30

    Dispersive liquid-liquid microextraction with and without ultrasound assistance (DLLME, UA-DLLME) and microextraction with packed sorbent (MEPS) methods for the extraction and determination of eight different benzodiazepines (BDZ) (chlordiazepoxide, flurazepam, bromazepam, oxazepam, lorazepam, clobazam, clonazepam, and flunitrazepam) in three commercial non-alcoholic and light alcoholic beverages were optimized and compared. Benzodiazepines are frequently used for their extensive diffusion and strong numbing effect in drug-facilitated crimes (DFC). The tiny small amount of sample required for DLLME and MEPS extraction makes them very suitable for specimens collected at the crime scene of DFCs. Microextraction techniques are of increasing interest thanks to their accordance to green analytical chemistry (GAC) guidelines providing good recovery values. Ultrasound assistance (UA-DLLME) was used to investigate whether this type of energy can improve the recoveries of the analytes. Analyses of the extracts were performed with reverse-phase capillary high-performance liquid chromatography with UV detection (HPLC - UV), thanks to low environmental impact, robustness, diffusion, and affordability. Recovery percentages at three different concentrations in the three beverages were between 14.30% and 103.28% with intraday and interday RSD lower than ±2.78%. The same samples were extracted using a MEPS protocol, and the results were compared with those obtained with DLLME. MEPS gave recoveries between 20.90% and 101.88% for all matrices showing a better performance than DLLME at higher concentrations, though lower recoveries were observed with diluted samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Luteolin as reactive oxygen generator by X-ray and UV irradiation

    Science.gov (United States)

    Toyama, Michiru; Mori, Takashi; Takahashi, Junko; Iwahashi, Hitoshi

    2018-05-01

    Non-toxic X-ray-responsive substances can be used in the radiosensitization of cancer, like porphyrin mediated radiotherapy. However, most X-ray-responsive substances are toxic. To find novel non-toxic X-ray-responsive substances, we studied the X-ray and UV reactivity of 40 non-toxic compounds extracted from plants. Dihydroethidium was used as an indicator to detect reactive oxygen species (ROS) generated by the compounds under X-ray or UV irradiation. We found that 13 of the investigated compounds generated ROS under X-ray irradiation and 17 generated ROS under UV irradiation. Only 4 substances generated ROS under both X-ray and UV. In particular, luteolin exhibited the highest activity among the investigated compounds; therefore, the ROS generated by luteolin were thoroughly characterized. To identify the ROS, we employed a combination of ROS detection reagents and their quenchers. O2·- generation by luteolin was monitored using dihydroethidium and superoxide dismutase (as an O2·- quencher). OH· and 1O2 generation was determined using aminophenyl fluorescein with ethanol (OH· quencher) and Singlet Oxygen Sensor Green® with NaN3 (1O2 quencher), respectively. Generation of O2·- under X-ray and UV irradiation was observed; however, no OH· or 1O2 was detected. The production of ROS from luteolin is surprising, because luteolin is a well-known antioxidant.

  8. Compatible validated spectrofluorimetric and spectrophotometric methods for determination of vildagliptin and saxagliptin by factorial design experiments

    Science.gov (United States)

    Abdel-Aziz, Omar; Ayad, Miriam F.; Tadros, Mariam M.

    2015-04-01

    Simple, selective and reproducible spectrofluorimetric and spectrophotometric methods have been developed for the determination of vildagliptin and saxagliptin in bulk and their pharmaceutical dosage forms. The first proposed spectrofluorimetric method is based on the dansylation reaction of the amino group of vildagliptin with dansyl chloride to form a highly fluorescent product. The formed product was measured spectrofluorimetrically at 455 nm after excitation at 345 nm. Beer's law was obeyed in a concentration range of 100-600 μg ml-1. The second proposed spectrophotometric method is based on the charge transfer complex of saxagliptin with tetrachloro-1,4-benzoquinone (p-chloranil). The formed charge transfer complex was measured spectrophotometrically at 530 nm. Beer's law was obeyed in a concentration range of 100-850 μg ml-1. The third proposed spectrophotometric method is based on the condensation reaction of the primary amino group of saxagliptin with formaldehyde and acetyl acetone to form a yellow colored product known as Hantzsch reaction, measured at 342.5 nm. Beer's law was obeyed in a concentration range of 50-300 μg ml-1. All the variables were studied to optimize the reactions' conditions using factorial design. The developed methods were validated and proved to be specific and accurate for quality control of vildagliptin and saxagliptin in their pharmaceutical dosage forms.

  9. Spectrophotometric assay of creatinine in human serum sample

    Directory of Open Access Journals (Sweden)

    Avinash Krishnegowda

    2017-05-01

    Full Text Available A new spectrophotometric method for the analysis of creatinine concentration in human serum samples is developed. The method explores the oxidation of p-methylamino phenol sulfate (Metol in the presence of copper sulfate and creatinine which yields an intense violet colored species with maximum absorbance at 530 nm. The calibration graph of creatinine by fixed time assay ranged from 4.4 to 620 μM. Recovery of creatinine in human serum samples varied from 101% to 106%. Limit of detection and limit of quantification were 0.145 μM and 0.487 μM respectively. Sandell’s sensitivity was 0.112 μg cm−2 and molar absorptivity was 0.101 × 104 L mol−1 cm−1. Within day precision was 2.5–4.8% and day-to-day precision range was 3.2–7.8%. The robustness and ruggedness of the method expressed in RSD values ranged from 0.78% to 2.12% and 1.32% to 3.46% respectively, suggesting that the developed method was rugged. This method provides good sensitivity and is comparable to standard Jaffe’s method with comparatively less interference from foreign substances.

  10. Spectrophotometric determination of total lactones in Andrographis paniculata Nees

    Directory of Open Access Journals (Sweden)

    Napaporn Jantakun

    2005-11-01

    Full Text Available A spectrophotometric method for determination of total lactones in Andrographis paniculata was established by using dinitrobenzoic acid and potassium hydroxide solutions as colour forming agents. The absorbance of the solution was determined at 536 nm. The linearity range was 12-72 × 10-6 g.ml-1. The detection limit was 1.2 μg, the quantitation limit was 4.23 μg. The intraday variation had an average of slope 6082.97 g.ml-1, % RSD 0.10; an average intercept 0.2786, %RSD 3.66 (n=3. The interday variation had an average of 6146 g.ml-1 with the %RSD of 6.30 and an average intercept 0.2628, %RSD 4.95 (n=4. The coefficients of determination were 0.998-0.999. The total lactones content, calculated as andrographolide, determined by this method was 8.61±0.52% (n=4 and by the official method, Thai Herbal Pharmacopoeia, was 8.12±0.34% (n=2. The results of the two methods do not differ significantly at P=0.05 (P(|t|>0.903 = 0.53

  11. Interaction betwen Lead and Bone Protein to Affect Bone Calcium Level Using UV-Vis Spectroscopy

    Science.gov (United States)

    Noor, Z.; Azharuddin, A.; Aflanie, I.; Kania, N.; Suhartono, E.

    2018-05-01

    This present study aim to evaluate the interactions between lead (Pb) and with bone protein by UV-Vis approach. In addition, this prsent study also aim to investigate the effect of Pb on bone calcium (Ca) level. The present study was a true experimental study design to examine the impact of Pb exposure in bone of male rats (Rattus novergicus). The study involved 5 groups, P1 was the control group, while the other (P2-P5) were the case group with exposure of Pb in different concentration within 4 weeks. At the end of the exposure, the interaction between Pb and protein was determined using UV-Vis spectrophotometric method, and the Ca level was determined using permanganometric method. The results shows that that there is an interaction between Pb and bone protein. The result also shows that the value of the binding constant of Protein-Pb is 32.71. It means Pb have an high affinity to bind with bone protein, which promote a further reaction to induced the release of bone Ca from the bone protein. In conclusion, this present study found an obvious relationship between Pb and bone protein which promote a further reaction to increase the releasing of bone calcium.

  12. The application of HPLC with on-line coupled UV/MS-biochemical detection for isolation of an acetylcholinesterase inhibitor from Narcissus 'Sir Winston Churchill'

    NARCIS (Netherlands)

    Ingkaninan, K.; Hazekamp, A.; de Best, C.M.; Irth, H.; Tjaden, U.R.; van der Heijden, R.; van der Greef, J.; Verpoorte, R.

    2000-01-01

    An HPLC with on-line coupled UV/MS-biochemical detection method for acetylcholinesterase (AChE) inhibitors in natural sources has been developed. The potential of this method is shown by the isolation of a new AChE inhibitor from the alcoholic extract of Narcissus 'Sir Winston Churchill'. Combining

  13. Oxidation by-products and ecotoxicity assessment during the photodegradation of fenofibric acid in aqueous solution with UV and UV/H{sub 2}O{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Santiago, Javier [Department of Chemical Engineering, University of Alcala, E-28771 Alcala de Henares (Spain); Agueera, Ana; Mar Gomez-Ramos, Maria del [Department of Analytical Chemistry, University of Almeria, E-04010 Almeria (Spain); Fernandez Alba, Amadeo R. [Department of Analytical Chemistry, University of Almeria, E-04010 Almeria (Spain); Advanced Study Institute of Madrid, IMDEA-Agua, Parque Cientifico Tecnologico, E-28805 Alcala de Henares, Madrid (Spain); Garcia-Calvo, Eloy [Department of Chemical Engineering, University of Alcala, E-28771 Alcala de Henares (Spain); Advanced Study Institute of Madrid, IMDEA-Agua, Parque Cientifico Tecnologico, E-28805 Alcala de Henares, Madrid (Spain); Rosal, Roberto, E-mail: roberto.rosal@uah.es [Department of Chemical Engineering, University of Alcala, E-28771 Alcala de Henares (Spain); Advanced Study Institute of Madrid, IMDEA-Agua, Parque Cientifico Tecnologico, E-28805 Alcala de Henares, Madrid (Spain)

    2011-10-30

    Highlights: {yields} UV and UV/H{sub 2}O{sub 2} photolysis of fenofibric acid. {yields} Identification of reaction intermediates using exact mass measurements. {yields} UV/H{sub 2}O{sub 2} removed toxicity towards Pseudokirchneriella subcapitata. {yields} Irradiated samples contain a number of chlorinated products. - Abstract: The degradation of an aqueous solution of fenofibric acid was investigated using ultraviolet (UV) photolysis and UV/H{sub 2}O{sub 2} with a low-pressure mercury lamp. We obtained quantum yields at different temperatures and the rate constant for the reaction of fenofibric acid with hydroxyl radicals. The maximum radical exposure per fluence ratio obtained was 1.4 x 10{sup -10} M L{sup -1} mW{sup -1}. Several reaction intermediates were detected by means of exact mass measurements performed by liquid chromatography coupled to quadrupole-time-of-flight mass spectrometry (LC-ESI-QTOF-MS). UV and UV/H{sub 2}O{sub 2} pathways involve the decarboxylation of fenofibric acid to 4-chloro-4'-(1-hydroxy-1-methylethyl)benzophenone and other minor products, predominantly chlorinated aromatics. We detected several intermediates from reactions with hydroxyl radicals and some lower molecular weight products from the scission of the carbonyl carbon-to-aromatic-carbon bond. We recorded high toxicity in UV irradiated samples for the growth of Pseudokirchneriella subcapitata even after the total depletion of fenofibric acid; this was probably due to the presence of chlorinated aromatics. A degree of toxicity reappeared in highly irradiated UV/H{sub 2}O{sub 2} samples, probably because of the formation of ring-opening products. The degree of mineralization was closely related to that of dechlorination and reached values of over 50% after 3-4 min before stabilizing thereafter.

  14. Immuno-magnetic beads-based extraction-capillary zone electrophoresis-deep UV laser-induced fluorescence analysis of erythropoietin.

    Science.gov (United States)

    Wang, Heye; Dou, Peng; Lü, Chenchen; Liu, Zhen

    2012-07-13

    Erythropoietin (EPO) is an important glycoprotein hormone. Recombinant human EPO (rhEPO) is an important therapeutic drug and can be also used as doping reagent in sports. The analysis of EPO glycoforms in pharmaceutical and sports areas greatly challenges analytical scientists from several aspects, among which sensitive detection and effective and facile sample preparation are two essential issues. Herein, we investigated new possibilities for these two aspects. Deep UV laser-induced fluorescence detection (deep UV-LIF) was established to detect the intrinsic fluorescence of EPO while an immuno-magnetic beads-based extraction (IMBE) was developed to specifically extract EPO glycoforms. Combined with capillary zone electrophoresis (CZE), CZE-deep UV-LIF allows high resolution glycoform profiling with improved sensitivity. The detection sensitivity was improved by one order of magnitude as compared with UV absorbance detection. An additional advantage is that the original glycoform distribution can be completely preserved because no fluorescent labeling is needed. By combining IMBE with CZE-deep UV-LIF, the overall detection sensitivity was 1.5 × 10⁻⁸ mol/L, which was enhanced by two orders of magnitude relative to conventional CZE with UV absorbance detection. It is applicable to the analysis of pharmaceutical preparations of EPO, but the sensitivity is insufficient for the anti-doping analysis of EPO in blood and urine. IMBE can be straightforward and effective approach for sample preparation. However, antibodies with high specificity were the key for application to urine samples because some urinary proteins can severely interfere the immuno-extraction. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Two-photon excitation in chip electrophoresis enabling label-free fluorescence detection in non-UV transparent full-body polymer chips.

    Science.gov (United States)

    Geissler, David; Belder, Detlev

    2015-12-01

    One of the most commonly employed detection methods in microfluidic research is fluorescence detection, due to its ease of integration and excellent sensitivity. Many analytes though do not show luminescence when excited in the visible light spectrum, require suitable dyes. Deep-ultraviolet (UV) excitation (electrophoresis of small aromatic compounds. Various polymers, such as poly(methyl methacrylate), cyclic olefin polymer, and copolymer as well as poly(dimethylsiloxane) were investigated and compared with respect to achievable LOD and ruggedness against photodamage. To demonstrate the applicability of the technique, the method was also applied to the determination of serotonin and tryptamine in fruit samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. A PLS-based extractive spectrophotometric method for simultaneous determination of carbamazepine and carbamazepine-10,11-epoxide in plasma and comparison with HPLC

    Science.gov (United States)

    Hemmateenejad, Bahram; Rezaei, Zahra; Khabnadideh, Soghra; Saffari, Maryam

    2007-11-01

    Carbamazepine (CBZ) undergoes enzyme biotransformation through epoxidation with the formation of its metabolite, carbamazepine-10,11-epoxide (CBZE). A simple chemometrics-assisted spectrophotometric method has been proposed for simultaneous determination of CBZ and CBZE in plasma. A liquid extraction procedure was operated to separate the analytes from plasma, and the UV absorbance spectra of the resultant solutions were subjected to partial least squares (PLS) regression. The optimum number of PLS latent variables was selected according to the PRESS values of leave-one-out cross-validation. A HPLC method was also employed for comparison. The respective mean recoveries for analysis of CBZ and CBZE in synthetic mixtures were 102.57 (±0.25)% and 103.00 (±0.09)% for PLS and 99.40 (±0.15)% and 102.20 (±0.02)%. The concentrations of CBZ and CBZE were also determined in five patients using the PLS and HPLC methods. The results showed that the data obtained by PLS were comparable with those obtained by HPLC method.

  17. Occurrence and fate of benzotriazoles UV filters in a typical residential wastewater treatment plant in Harbin, China.

    Science.gov (United States)

    Zhao, Xue; Zhang, Zi-Feng; Xu, Lei; Liu, Li-Yan; Song, Wei-Wei; Zhu, Fu-Jie; Li, Yi-Fan; Ma, Wan-Li

    2017-08-01

    Benzotriazoles (BTs) UV filters are widely used as ultraviolet absorbents for our daily products, which received increasing attention in the past decades. Residential wastewater treatment plant (WWTP) is both an important sink for wastewater and a key pollution source for receiving water for these chemicals. In this study, pretreatment and gas chromatography-tandem mass spectrometry analysis method were developed to determine the occurrence and fate of 9 BTs UV filters in wastewater and sludge from the WWTP with anaerobic-oxic treatment process (A/O) and biological aerated filter treatment process (BAF). Totally, 81 wastewater samples and 11 sludge samples were collected in four seasons. In wastewater, UV-326 and UV-329 were frequently detected, while the highest mean concentrations were detected for UV-234 and UV-329. The concentrations were in the range of UV filters was >85% in A/O process and 60-77% in BAF process except for UV-350, which was more difficult to remove with lower removal efficiencies of 33.3% for both A/O and BAF. All the target chemicals except for UV-320 were detected in sludge samples with the mean concentration ranging from 0.90 ng/g to 303.39 ng/g. There was no significant difference with concentrations and removal efficiency among different seasons. Higher detection frequency and concentration of BTs UV filters in downstream of the receiving water system indicated the contribution of effluent of the WWTP. Compared with other rivers, the lower concentrations in surface water in the Songhua River indicated light pollution status with of BTs UV filters. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. OPTIMIZING CONDITIONS FOR SPECTROPHOTOMETRIC DETERMINATION OF TOTAL POLYPHENOLS IN WINES USING FOLIN-CIOCALTEU REAGENT

    Directory of Open Access Journals (Sweden)

    Daniel Bajčan

    2013-02-01

    Full Text Available Wine is a complex beverage that obtains its properties mainly due to synergistic effect of alcohol, organic acids, arbohydrates, as well as the phenolic and aromatic substances. At present days, we can observe an increased interest in the study of polyphenols in wines that have antioxidant, antimicrobial, anti-inflammatory, anti-cancer and many other beneficial effects. Moderate and regular consumption of the red wine especially, with a high content of phenolic compounds, has a beneficial effect on human health. The aim of this work was to optimize conditions for spectrophotometric determination of total polyphenols in winwas to optimize conditions for spectrophotometric determination of total polyphenols in winwas to optimize conditions for spectrophotometric determination of total polyphenols in winwas to optimize conditions for pectrophotometric determination of total polyphenols in wine using Folin-Ciocaulteu reagent. Based on several studies, in order to minimize chemical use and optimize analysis time, we have proposed a method for the determination of total polyphenols using 0.25 ml Folin-Ciocaulteu reagent, 3 ml of 20% Na2CO3 solution and time of coloring complex 1.5 hour. We f

  19. Spectrophotometric method for quantitative determination of triclabendazole in bulk and pharmaceutical

    Directory of Open Access Journals (Sweden)

    Alankar Shrivastava

    2011-01-01

    Full Text Available Background: Triclabendazole (TCBZ, 6-chloro-5(2-3 dichlorophenoxy-2-methyl thio-benzimidazole, an halogenated benzimidazole (BZD thiol derivative, shows high efficacy against both the immature and mature stages of Fasciola hepatica in sheep and cattle, which is a differential feature compared to other available trematodicidal drugs. As a consequence of its excellent activity against the liver fluke, it has been extensively used and this has inevitably promoted the selection of TCBZ-resistant populations, which is now a worrying problem in several areas of the world. We propose simple ultraviolet spectrophotometric method for the estimation of triclabendazole in 0.1 methanolic HCl for the estimation of the drug. Method was validated as per ICH guidelines. Materials and Methods: Spectral absorbance measurements were made on Shimadzu UV-1800 with 10 mm matched quartz cells and dilutions were made in 0.1 M methanolic HCl. Results: The LOD and LOQ of triclabendazole at 305 nm were found to be 0.068434 and 2.73×10-4 μg/ml respectively. The calibration was linear in the range of 1-10 μg/ml. Analytical parameters such as stability, selectivity, accuracy, and precision have been established for the method in Endex and Fasinex tablets and evaluated statistically to assess the application of the method. Conclusion: Method passes all parameters with in desirable limits and found to be simple, stable, sensitive, reproducible, and accurate for the routine analysis of the drug in pharmaceutical formulations and in pharmaceutical investigations involving triclabendazole.

  20. An Overview of Analytical Determination of Diltiazem, Cimetidine, Ranitidine, and Famotidine by UV Spectrophotometry and HPLC Technique

    Directory of Open Access Journals (Sweden)

    Nighat Shafi

    2013-01-01

    Full Text Available This review article recapitulates the analytical methods for the quantitative determinations of diltiazem and three H2 receptor antagonists (cimetidine, ranitidine, and famotidine by one of the spectroscopic technique (UV spectrophotometery and separation technique such as high-performance liquid chromatography (HPLC. The clinical and pharmaceutical analysis of these drugs requires effective analytical procedures for quality control, pharmaceutical dosage formulations, and biological fluids. An extensive survey of the literature published in various analytical and pharmaceutical chemistry-related journals has been compiled in its review. A synopsis of reported spectrophotometric and high-performance liquid chromatographic methods for individual drug is integrated. This appraisal illustrates that majority of the HPLC methods reviewed are based on the quantitative analysis of drugs in biological fluids, and they are appropriate for therapeutic drug monitoring purpose.

  1. Observation of the Crab Nebula with cosmic rays in the UV, or 'gamma astronomy at the moonlight'

    International Nuclear Information System (INIS)

    Sarazin, Xavier

    1994-01-01

    The aim of ARTEMIS (Antimatter Research Through the Earth Moon Ion Spectrometer) is to detect extragalactic antimatter at Very High (TeV) Energies in cosmic rays. The Earth's magnetic field is used as deflector of these ions, the moon serves as an absorber, and the atmosphere as a giant calorimeter. The cosmic rays are detected by Cerenkov imaging in the atmosphere. This Cerenkov flash must be detected in the UV because of the presence of moonlight, necessitating the construction of a novel UV camera. This is the first time Cerenkov imaging has been performed in the UV. The Crab Nebula, which has become a reference source for Very High Energy Gamma-ray Astronomy, enabled evaluation of the UV method in low moonlight. Our detection of a signal from the Crab validates, on the one hand, the Cerenkov imaging technique in the UV and, on the other hand, offers the possibility of uninterrupted nightly observations of a source, regardless of the moon's phase. (author) [fr

  2. Evaluation of Global Genomic DNA Methylation in Human Whole Blood by Capillary Electrophoresis UV Detection

    Directory of Open Access Journals (Sweden)

    Angelo Zinellu

    2017-01-01

    Full Text Available Alterations in global DNA methylation are implicated in various pathophysiological processes. The development of simple and quick, yet robust, methods to assess DNA methylation is required to facilitate its measurement and interpretation in clinical practice. We describe a highly sensitive and reproducible capillary electrophoresis method with UV detection for the separation and detection of cytosine and methylcytosine, after formic acid hydrolysis of DNA extracted from human whole blood. Hydrolysed samples were dried and resuspended with water and directly injected into the capillary without sample derivatization procedures. The use of a run buffer containing 50 mmol/L BIS-TRIS propane (BTP phosphate buffer at pH 3.25 and 60 mmol/L sodium acetate buffer at pH 3.60 (4 : 1, v/v allowed full analyte identification within 11 min. Precision tests indicated an elevated reproducibility with an interassay CV of 1.98% when starting from 2 μg of the extracted DNA. The method was successfully tested by measuring the DNA methylation degree both in healthy volunteers and in reference calf thymus DNA.

  3. Spectrophotometric determination of silica in water. Low range

    International Nuclear Information System (INIS)

    Acosta L, E.

    1992-07-01

    The spectrophotometric method for the determination of the silica element in water, demineralized water, raw waters, laundry waters, waters treated with ion exchange resins and sea waters is described. This method covers the determination of the silica element in the interval from 20 to 1000 μg/l on 50 ml. of base sample. These limits its can be variable if the size of the used aliquot one is changed for the final determination of the silica element. (Author)

  4. Presence of UV-endonuclease sensitive sites in daughter DNA of UV-irradiated mammalian cells

    International Nuclear Information System (INIS)

    D'Ambrosio, S.; Setlow, R.B.

    1978-02-01

    Asynchronous Chinese hamster cells were irradiated with 10 Jm -2 uv radiation and 0.25 to 4 hours later pulse-labeled with [ 3 H]thymidine. Cells synchronized by shaking off mitotic and G 1 cells were irradiated in either the G 1 -phase or S-phase of the cell cycle and pulse-labeled with [ 3 H]thymidine in the S-phase. After a 12 to 14 hour chase in unlabeled medium, the DNA was extracted, incubated with Micrococcus luteus uv-endonuclease and sedimented in alkaline sucrose. The number of endonuclease sensitive sites decreased as the time between uv irradiation and pulse-labeling of daughter DNA increased. Further, there were significantly less endonuclease sensitive sites in the daughter DNA from cells irradiated in the G 1 -phase than in the S-phase. These data indicate that very few, if any, dimers are transferred from parental DNA to daughter DNA and that the dimers detected in daughter DNA may be due to the irradiation of replicating daughter DNA before labeling

  5. A UV-Vis photoacoustic spectrophotometer.

    Science.gov (United States)

    Wiegand, Joseph R; Mathews, L Dalila; Smith, Geoffrey D

    2014-06-17

    A novel photoacoustic spectrophotometer (PAS) for the measurement of gas-phase and aerosol absorption over the UV-visible region of the spectrum is described. Light from a broadband Hg arc lamp is filtered in eight separate bands from 300 to 700 nm using bandpass interference filters (centered at 301 nm, 314 nm, 364 nm, 405 nm, 436 nm, 546 nm, 578 and 687 nm) and modulated with an optical chopper before entering the photoacoustic cell. All wavelength bands feature a 20-s detection limit of better than 3.0 Mm(-1) with the exception of the lower-intensity 687 nm band for which it is 10.2 Mm(-1). Validation measurements of gas-phase acetone and nigrosin aerosol absorption cross sections at several wavelengths demonstrate agreement to within 10% with those measured previously (for acetone) and those predicted by Mie theory (for nigrosin). The PAS instrument is used to measure the UV-visible absorption spectrum of ambient aerosol demonstrating a dramatic increase in the UV region with absorption increasing by 300% from 405 to 301 nm. This type of measurement throughout the UV-visible region and free from artifacts associated with filter-based methods has not been possible previously, and we demonstrate its promise for classifying and quantifying different types of light-absorbing ambient particles.

  6. Alanine dosimetry using a spectrophotometric ferric-xylenol orange complex readout

    International Nuclear Information System (INIS)

    Laere, K. van; Buysse, J.; Berkvens, P.

    1989-01-01

    The spectrophotometric dosimetric method using the indirect oxidation of ferrous ions after dissolution of irradiated DL-and L-alanine has been thoroughly investigated with respect to its composition, read-out procedure and dose-response. Optimal concentration of 0.10 N H 2 SO 4 , 0.2 mM xylenol orange and 0.2 mM Fe 2+ were found, giving an absorption maximum at 547 nm. Standardization of chemical processing procedures allows a reproducibility better than 0.5%. The useful dose range has been extended to 0.03-12 kGy by means of slightly different read-out procedure. The quantitative concept of ''indirect yield'', G id , was introduced for this procedure as a measure of the indirect oxidation capacity of the radicals. It was found to be G id,0 (Fe 3+ ) 7.1 ions/100 eV transferred into the alanine. The spectrophotometric readout combines the highly advantageous use of alanine as a dosemeter with the straightforwardness, accuracy and low costs of the chemical procedure. (author)

  7. Identification of antimycotic drugs transformation products upon UV exposure

    Energy Technology Data Exchange (ETDEWEB)

    Casado, Jorge; Rodríguez, Isaac, E-mail: isaac.rodriguez@usc.es; Ramil, María; Cela, Rafael

    2015-05-30

    Highlights: • Evaluation of antimycotic drugs UV stabilities in model supports. • Simultaneous detection of precursor drugs and transformation products. • Transformation products identification from their scan, accurate MS/MS spectra. • Directed search of identified transformation products in sand and soil samples. • Preliminary toxicity estimations. - Abstract: The reactivity of three imidazolic, environmental persistent antimycotic drugs (clotrimazole, CTZ; ketoconazole, KTZ; and miconazole, MCZ) upon exposure to ultraviolet (UV) radiation is discussed. First, precursor compounds were immobilized in a silicone support which was further exposed to UV light at two different wavelengths: 254 and 365 nm. After solvent desorption, degradation kinetics of the precursor pharmaceuticals, identification of the arising transformation products (TPs) and evaluation of their time-course were investigated by liquid chromatography (LC) with quadrupole time-of-flight (QTOF) mass spectrometry (MS) detection. The three antimycotics displayed similar stabilities when exposed to 254 nm light; however, CTZ was significantly more stable than MCZ and KTZ when irradiated with the 365 nm lamp. TPs identified in silicone supports resulted from de-chlorination, cleavage, intra-molecular cyclization and hydroxylation reactions. Many of these species were also detected when exposing other solid matrices, such as sand and agricultural soil, previously spiked with target compounds, to UV light. The 50% estimated lethal concentration, calculated using the 48-h Daphnia magna test, for the two main TPs of CTZ and MCZ, at both wavelengths, were lower than those corresponding to the precursor drugs.

  8. Identification of antimycotic drugs transformation products upon UV exposure

    International Nuclear Information System (INIS)

    Casado, Jorge; Rodríguez, Isaac; Ramil, María; Cela, Rafael

    2015-01-01

    Highlights: • Evaluation of antimycotic drugs UV stabilities in model supports. • Simultaneous detection of precursor drugs and transformation products. • Transformation products identification from their scan, accurate MS/MS spectra. • Directed search of identified transformation products in sand and soil samples. • Preliminary toxicity estimations. - Abstract: The reactivity of three imidazolic, environmental persistent antimycotic drugs (clotrimazole, CTZ; ketoconazole, KTZ; and miconazole, MCZ) upon exposure to ultraviolet (UV) radiation is discussed. First, precursor compounds were immobilized in a silicone support which was further exposed to UV light at two different wavelengths: 254 and 365 nm. After solvent desorption, degradation kinetics of the precursor pharmaceuticals, identification of the arising transformation products (TPs) and evaluation of their time-course were investigated by liquid chromatography (LC) with quadrupole time-of-flight (QTOF) mass spectrometry (MS) detection. The three antimycotics displayed similar stabilities when exposed to 254 nm light; however, CTZ was significantly more stable than MCZ and KTZ when irradiated with the 365 nm lamp. TPs identified in silicone supports resulted from de-chlorination, cleavage, intra-molecular cyclization and hydroxylation reactions. Many of these species were also detected when exposing other solid matrices, such as sand and agricultural soil, previously spiked with target compounds, to UV light. The 50% estimated lethal concentration, calculated using the 48-h Daphnia magna test, for the two main TPs of CTZ and MCZ, at both wavelengths, were lower than those corresponding to the precursor drugs

  9. Determination of flavonoids in cultivated sugarcane leaves, bagasse, juice and in transgenic sugarcane by liquid chromatography-UV detection.

    Science.gov (United States)

    Colombo, Renata; Lanças, Fernando M; Yariwake, Janete H

    2006-01-20

    A high-performance liquid chromatography (HPLC) method with photo-diode array (DAD) detection was developed to separate and quantify flavonoids in sugarcane leaves and bagasse (= the crushed sugarcane refuse from juice extraction), and in sugarcane juice. Sugarcane flavonoids consist of a complex mixture of aglycones and glycosides (including flavonolignan glycosides), and the HPLC-UV method herein proposed is suitable for their quantification as total flavonoids. This method was applied to analyze samples of cultivated sugarcane, commercial juice and transgenic sugarcane leaves. Sugarcane leaves proved a promising source of flavonoids: an average of 1.10 mg of total flavonoids/g plant material was found in fresh leaves. Moreover, the flavonoid content of sugarcane juice (0.6 mg/mL) is comparable to other food sources of flavonoids previously reported. Transgenic sugarcane leaves ("Bowman-Birk" and "Kunitz") were compared with non-modified ("control") plant samples using the proposed HPLC-UV method, which indicated that the content of total flavonoids in transgenic plants is different from that in non-modified sugarcane.

  10. SHARDS: AN OPTICAL SPECTRO-PHOTOMETRIC SURVEY OF DISTANT GALAXIES

    International Nuclear Information System (INIS)

    Pérez-González, Pablo G.; Cava, Antonio; Barro, Guillermo; Villar, Víctor; Cardiel, Nicolás; Espino, Néstor; Gallego, Jesús; Ferreras, Ignacio; Rodríguez-Espinosa, José Miguel; Balcells, Marc; Cepa, Jordi; Alonso-Herrero, Almudena; Cenarro, Javier; Charlot, Stéphane; Cimatti, Andrea; Conselice, Christopher J.; Daddi, Emmanuele; Elbaz, David; Donley, Jennifer; Gobat, R.

    2013-01-01

    We present the Survey for High-z Absorption Red and Dead Sources (SHARDS), an ESO/GTC Large Program carried out using the OSIRIS instrument on the 10.4 m Gran Telescopio Canarias (GTC). SHARDS is an ultra-deep optical spectro-photometric survey of the GOODS-N field covering 130 arcmin 2 at wavelengths between 500 and 950 nm with 24 contiguous medium-band filters (providing a spectral resolution R ∼ 50). The data reach an AB magnitude of 26.5 (at least at a 3σ level) with sub-arcsec seeing in all bands. SHARDS' main goal is to obtain accurate physical properties of intermediate- and high-z galaxies using well-sampled optical spectral energy distributions (SEDs) with sufficient spectral resolution to measure absorption and emission features, whose analysis will provide reliable stellar population and active galactic nucleus (AGN) parameters. Among the different populations of high-z galaxies, SHARDS' principal targets are massive quiescent galaxies at z > 1, whose existence is one of the major challenges facing current hierarchical models of galaxy formation. In this paper, we outline the observational strategy and include a detailed discussion of the special reduction and calibration procedures which should be applied to the GTC/OSIRIS data. An assessment of the SHARDS data quality is also performed. We present science demonstration results on the detection and study of emission-line galaxies (star-forming objects and AGNs) at z = 0-5. We also analyze the SEDs for a sample of 27 quiescent massive galaxies with spectroscopic redshifts in the range 1.0 < z ∼< 1.4. We discuss the improvements introduced by the SHARDS data set in the analysis of their star formation history and stellar properties. We discuss the systematics arising from the use of different stellar population libraries, typical in this kind of study. Averaging the results from the different libraries, we find that the UV-to-MIR SEDs of the massive quiescent galaxies at z = 1.0-1.4 are well

  11. SHARDS: AN OPTICAL SPECTRO-PHOTOMETRIC SURVEY OF DISTANT GALAXIES

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Gonzalez, Pablo G.; Cava, Antonio; Barro, Guillermo; Villar, Victor; Cardiel, Nicolas; Espino, Nestor; Gallego, Jesus [Departamento de Astrofisica, Facultad de CC. Fisicas, Universidad Complutense de Madrid, E-28040 Madrid (Spain); Ferreras, Ignacio [Mullard Space Science Laboratory, University College London, Holmbury St Mary, Dorking, Surrey RH5 6NT (United Kingdom); Rodriguez-Espinosa, Jose Miguel; Balcells, Marc; Cepa, Jordi [Instituto de Astrofisica de Canarias, E-38200 La Laguna, Tenerife (Spain); Alonso-Herrero, Almudena [Instituto de Fisica de Cantabria, CSIC-Universidad de Cantabria, E-39005 Santander (Spain); Cenarro, Javier [Centro de Estudios de Fisica del Cosmos de Aragon, Plaza San Juan 1, Planta 2, E-44001 Teruel (Spain); Charlot, Stephane [Institut d' Astrophysique de Paris, CNRS, Universite Pierre and Marie Curie, UMR 7095, 98bis bd Arago, F-75014 Paris (France); Cimatti, Andrea [Dipartimento di Astronomia, Universita degli Studi di Bologna, I-40127 Bologna (Italy); Conselice, Christopher J. [School of Physics and Astronomy, University of Nottingham, Nottingham NG7 2RD (United Kingdom); Daddi, Emmanuele; Elbaz, David [CEA, Laboratoire AIM, Irfu/SAp, F-91191 Gif-sur-Yvette (France); Donley, Jennifer [Los Alamos National Laboratory, Los Alamos, NM (United States); Gobat, R. [Laboratoire AIM-Paris-Saclay, CEA/DSM-CNRS-Universite Paris Diderot, Irfu/Service d' Astrophysique, CEA Saclay, Orme des Merisiers, F-91191 Gif-sur-Yvette (France); and others

    2013-01-01

    We present the Survey for High-z Absorption Red and Dead Sources (SHARDS), an ESO/GTC Large Program carried out using the OSIRIS instrument on the 10.4 m Gran Telescopio Canarias (GTC). SHARDS is an ultra-deep optical spectro-photometric survey of the GOODS-N field covering 130 arcmin{sup 2} at wavelengths between 500 and 950 nm with 24 contiguous medium-band filters (providing a spectral resolution R {approx} 50). The data reach an AB magnitude of 26.5 (at least at a 3{sigma} level) with sub-arcsec seeing in all bands. SHARDS' main goal is to obtain accurate physical properties of intermediate- and high-z galaxies using well-sampled optical spectral energy distributions (SEDs) with sufficient spectral resolution to measure absorption and emission features, whose analysis will provide reliable stellar population and active galactic nucleus (AGN) parameters. Among the different populations of high-z galaxies, SHARDS' principal targets are massive quiescent galaxies at z > 1, whose existence is one of the major challenges facing current hierarchical models of galaxy formation. In this paper, we outline the observational strategy and include a detailed discussion of the special reduction and calibration procedures which should be applied to the GTC/OSIRIS data. An assessment of the SHARDS data quality is also performed. We present science demonstration results on the detection and study of emission-line galaxies (star-forming objects and AGNs) at z = 0-5. We also analyze the SEDs for a sample of 27 quiescent massive galaxies with spectroscopic redshifts in the range 1.0 < z {approx}< 1.4. We discuss the improvements introduced by the SHARDS data set in the analysis of their star formation history and stellar properties. We discuss the systematics arising from the use of different stellar population libraries, typical in this kind of study. Averaging the results from the different libraries, we find that the UV-to-MIR SEDs of the massive quiescent galaxies at

  12. Extractive spectrophotometric determination of thorium

    International Nuclear Information System (INIS)

    Venkatesan, M.; Gopalakrishnan, V.; Ramanujam, A.; Nadkarni, M.N.

    1981-01-01

    An extractive spectrophotometric method has been standardized for the analysis of 0.2 to 1.6 milligrams of thorium present in nitric acid solutions. The method involves the extraction of thorium from nitric acid solutions into 0.5 M thenoyl trifluoro acetone (HTTA) in benzene and its direct estimation from the organic extract by spectrophotometry as Thoron colour complex. In this method, interference due to iron upto 5 milligrams can be suppressed by adding ascorbic acid in the ratio of 1:2 prior to HTTA extraction. Uranium(VI) does not interefere even when present in 2000 times the amount of thorium. Plutonium and cerium do not interfere at one milligram level whereas zirconium interferes in this method. The overall error variation and precision of this method has been determined to be +- 3.5%. (author)

  13. Spectrophotometric calibration system for DECam

    Science.gov (United States)

    Rheault, J.-P.; DePoy, D. L.; Marshall, J. L.; Prochaska, T.; Allen, R.; Wise, J.; Martin, E.; Williams, P.

    2012-09-01

    We describe a spectrophotometric calibration system that is being implemented as part of the DES DECam project at the Blanco 4 meter at CTIO. Our calibration system uses a 1nm wide tunable source to measure the instrumental response function of the telescope optics and detector from 300nm up to 1100nm. This calibration will be performed regularly to monitor any change in the transmission function of the telescope during the 5 year survey. The system consists of a monochromator based tunable light source that provides illumination on a dome flat that is monitored by calibrated photodiodes that allow us to measure the telescope throughput as a function of wavelength. Our system has a peak output power of 2 mW, equivalent to a flux of approximately 800 photons/s/pixel on DECam.

  14. Preconcentration of Sn (II) using the methylene blue on the activated carbon and its determination by spectrophotometry method.

    Science.gov (United States)

    Khodadoust, Saeid; Cham Kouri, Narges

    2014-04-05

    A simple and accurate spectrophotometric method for determination of trace amounts of Sn (II) ion in soil sample was developed by using the methylene blue (MB) in the presence of activated carbon (AC) as the adsorbent Solid Phase Extraction (SPE) of Sn (II) and then determined by UV-Vis. The Beer's law is obeyed over the concentration range of 1-80ngmL(-1) of Sn (II) with the detection limits of 0.34ngmL(-1). The influence of type and volume of eluent, concentration of MB, pH, and amount of AC on sensitivity of spectrophotometric method were optimized. The method has been successfully applied for Sn (II) ion determination in soil sample. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Determination of cyanide by a highly sensitive indirect spectrophotometric method.

    Science.gov (United States)

    Blanco, M; Maspoch, S

    1984-01-01

    Complexation of Pd(2+) with cyanide inhibits the extraction of the palladium complex of 5-phenylazo-8-aminoquinoline. This effect is used for the indirect spectrophotometric determination of cyanide at the mug level. Cyanide in industrial waste water and in sea-water is determined after distillation as HCN from the sample and collection in sodium hydroxide solution.

  16. Spectrophotometric investigation into iodine-electron donor systems at low temperature

    International Nuclear Information System (INIS)

    Gorodyskij, V.A.; Morachevskij, A.A.

    1978-01-01

    Iodine-sec. butanol (n-donor) and iodine - hexene - 1 (π-donor) have been investigated for the first time by the spectrophotometric method in the wide temeprature range (77-293 K). The existence of complexes with a charge transfer of the type, which is characterized by the long-wave absorption band in electron spectra, is determined in the systems

  17. UV-induced structural changes in chromatin

    International Nuclear Information System (INIS)

    Lang, H.; Zimmer, C.; Vengerov, Yu.Yu.

    1985-01-01

    UV-induced structural alterations of chromatin were studied by means of CD, electron microscopic, and gel electrophoretic measurements. The results indicate that chromatin undergoes serious structural changes after irradiation even at very low fluences. In the low fluence range the structural transitions from the higher ordered chromatin structure to the unfolded state occur without detectable changes in the content of histone H1 and of the core histones. Histone H1 disappears only at fluences above 10 kJ/m 2 . Furthermore, DNA in chromatin is much more sensitive against UV-irradiation and shows a higher degree of strand scission relative to free DNA. While fragmentation in free DNA occurs at fluences above 15 kJ/m 2 , it occurs even at 5.5 kJ/m 2 in the case of chromatin. The biological meaning of the observed UV-induced structural alterations of chromatin is discussed. (author)

  18. Structural elucidation and estimation of the acute toxicity of the major UV-visible photoproduct of fludioxonil - detection in both skin and flesh samples of grape.

    Science.gov (United States)

    Lassalle, Yannick; Nicol, Édith; Genty, Christophe; Bourcier, Sophie; Bouchonnet, Stéphane

    2015-06-01

    Ultraviolet (UV)-visible irradiation of fludioxonil was investigated with two photoreactors using either a mercury or xenon vapor lamp. In both cases, it led to the formation of only one photoproduct in significant amount: 2-(2,2-difluorobenzo[d][1,3]dioxol-4-yl)-2-(nitrosomethylene)-4-oxobutanenitrile, which has been characterized using Liquid Chromatography - High Resolution - Tandem Mass Spectrometry (LC-HR-MS/MS) coupling. A photolysis pathway has been proposed to rationalize its formation in degassed water. In vitro bioassays on Vibrio fischeri bacteria showed that UV-vis irradiation of an aqueous solution of fludioxonil significantly increases its toxicity. Because no other by-product was detected in significant amount, the photoproduct mentioned above may be considered mainly responsible for this increase in toxicity. Grape berries treated with a 50 ppm aqueous solution of fludioxonil were submitted to UV-visible irradiation under laboratory conditions. The fungicide and photoproduct were detected in both skin and flesh of berries, even after they have been rinsed with water. The ability of the photoproduct to pass through the fruit skin is comparable with that of fludioxonil. These results are of concern for consumers because they mean that water tap rinsing does not lead to efficient removing of both compounds. Copyright © 2015 John Wiley & Sons, Ltd.

  19. A New Spectrophotometric Method for Determination of Selenium in Cosmetic and Pharmaceutical Preparations after Preconcentration with Cloud Point Extraction

    Directory of Open Access Journals (Sweden)

    Mohammad Hosein Soruraddin

    2011-01-01

    Full Text Available A simple, rapid, and sensitive spectrophotometric method for the determination of trace amounts of selenium (IV was described. In this method, all selenium spices reduced to selenium (IV using 6 M HCl. Cloud point extraction was applied as a preconcentration method for spectrophotometric determination of selenium (IV in aqueous solution. The proposed method is based on the complexation of Selenium (IV with dithizone at pH < 1 in micellar medium (Triton X-100. After complexation with dithizone, the analyte was quantitatively extracted to the surfactant-rich phase by centrifugation and diluted to 5 mL with methanol. Since the absorption maxima of the complex (424 nm and dithizone (434 nm overlap, hence, the corrected absorbance, Acorr, was used to overcome the problem. With regard to the preconcentration, the tested parameters were the pH of the extraction, the concentration of the surfactant, the concentration of dithizone, and equilibration temperature and time. The detection limit is 4.4 ng mL-1; the relative standard deviation for six replicate measurements is 2.18% for 50 ng mL-1 of selenium. The procedure was applied successfully to the determination of selenium in two kinds of pharmaceutical samples.

  20. Two UV colours of the central part of M 31

    Science.gov (United States)

    Deharveng, J. M.; Laget, M.; Monnet, G.; Vuillemin, A.

    1976-01-01

    Two photographs of the galaxy M 31 have been obtained in the far UV with a Faust rocket experiment and in the near UV with the S 183 experiment aboard Skylab. Only the central part of the galaxy is detected. Reductions provide both the energy received and the angular area over M 31 from which it is emitted. The UV flux is brighter than expected from extrapolation of the visible spectrum. The distribution below 300 A is rather flat and different from previous OAO-2 observations. These results, combined with Lyman continuum flux evaluation, are used to discuss the temperature and the age of the stars which may be responsible for this anomalous UV distribution.

  1. Thorium spectrophotometric analysis with high precision

    International Nuclear Information System (INIS)

    Palmieri, H.E.L.

    1983-06-01

    An accurate and precise determination of thorium is proposed. Precision of about 0,1% is required for the determination of macroquantities of thorium processed. After an extensive literature search concerning this subject, spectrophotometric titration has been chosen, using disodium ethylenediaminetetraacetate (EDTA) solution and alizarin S as indicator. In order to obtain such a precision, an amount of 0,025 M EDTA solution precisely measured has been added and the titration was completed with less than 5 ml of 0,0025 M EDTA solution. It is usual to locate the end-point graphically, by plotting added titrant versus absorbance. The non-linear minimum square fit, using the Fletcher e Powell's minimization process and a computer program. (author)

  2. Occurrence and fate of benzotriazoles UV filters in a typical residential wastewater treatment plant in Harbin, China

    International Nuclear Information System (INIS)

    Zhao, Xue; Zhang, Zi-Feng; Xu, Lei; Liu, Li-Yan; Song, Wei-Wei; Zhu, Fu-Jie; Li, Yi-Fan; Ma, Wan-Li

    2017-01-01

    Benzotriazoles (BTs) UV filters are widely used as ultraviolet absorbents for our daily products, which received increasing attention in the past decades. Residential wastewater treatment plant (WWTP) is both an important sink for wastewater and a key pollution source for receiving water for these chemicals. In this study, pretreatment and gas chromatography-tandem mass spectrometry analysis method were developed to determine the occurrence and fate of 9 BTs UV filters in wastewater and sludge from the WWTP with anaerobic-oxic treatment process (A/O) and biological aerated filter treatment process (BAF). Totally, 81 wastewater samples and 11 sludge samples were collected in four seasons. In wastewater, UV-326 and UV-329 were frequently detected, while the highest mean concentrations were detected for UV-234 and UV-329. The concentrations were in the range of UV filters was >85% in A/O process and 60–77% in BAF process except for UV-350, which was more difficult to remove with lower removal efficiencies of 33.3% for both A/O and BAF. All the target chemicals except for UV-320 were detected in sludge samples with the mean concentration ranging from 0.90 ng/g to 303.39 ng/g. There was no significant difference with concentrations and removal efficiency among different seasons. Higher detection frequency and concentration of BTs UV filters in downstream of the receiving water system indicated the contribution of effluent of the WWTP. Compared with other rivers, the lower concentrations in surface water in the Songhua River indicated light pollution status with of BTs UV filters. - Highlights: • UV-234 and UV-329 were the predominated compounds in residential wastewater. • The A/O treatment process had higher removal effect than the BAF treatment process. • Removal efficiency of UV filters was not significantly influenced by season changes. • Effluent from the WWTP was not the

  3. The development of a new inhibition kinetic spectrophotometric method for determination of phenylhydrazine

    Directory of Open Access Journals (Sweden)

    VIOLETA D. MITIC

    2005-07-01

    Full Text Available Anew sensitive kinetic method has been developed for the determination of trace amounts of phenylhydrazine in the range of 1.08×10-7 to 1.08×10-6 g/cm3. The detection limit of this method is 0.008 mg/cm3, based on the 3Sb criterion. Themethod is based on the inhibitory effect of phenylhydrazine on the oxidation of Victoria Blue 4-R by KBrO3. The reaction was monitored spectrophotometrically at 596.3 nm. The method development includes the optimization of the reagent concentration and temperature. The kinetic parameters of the reaction are reported and a rate equation is suggested. The effects of certain foreign ions upon the reaction rate were determined for the assessment of the selectivity of the method. The new developedmethod was found to have fairly good selectivity, sensitivity, simplicity and rapidity.

  4. Characterisation of extracts of Hypericum perforatum L. using an on-line HPLC system with UV/visible and fluorescence detection prior to and after photochemical conversion of the effluent

    DEFF Research Database (Denmark)

    Jensen, A. G.; Cornett, Claus; Gudiksen, L.

    2000-01-01

    was illuminated with UV light at 254 nm for 1 min. The apparent content of hypericins was dependent on the mode of detection, and it is therefore of importance to state carefully the mode of detection in any analytical method in order to use the method for reproducible standardisation procedures. Copyright (C...

  5. Evaluating UV-C LED disinfection performance and ...

    Science.gov (United States)

    This study evaluated ultraviolet (UV) light emitting diodes (LEDs) emitting at 260 nm, 280 nm, and the combination of 260|280 nm together for their efficacy at inactivating Escherichia. coli, MS2 coliphage, human adenovirus type 2 (HAdV2), and Bacillus pumilus spores; research included an evaluation of genomic damage. Inactivation by the LEDs was compared with the efficacy of conventional UV sources, the low-pressure (LP) and medium-pressure (MP) mercury vapor lamps. The work also calculated the electrical energy per order of reduction of the microorganisms by the five UV sources.For E. coli, all five UV sources yielded similar inactivation rates. For MS2 coliphage, the 260 nm LED was most effective. For HAdV2 and B. pumilus, the MP UV lamp was significantly more effective than the LP UV and UVC LED sources. When considering electrical energy per order of reduction, the LP UV lamp was the most efficient for E. coli and MS2, and the MPUV and LPUV were equally efficient for HAdV2 and B. pumilus spores. Among the UVC LEDs, the 280 nm LED unit required the least energy per log reduction of E. coli and HAdV2. The 280 nm and 260|280 nm LED units were equally efficient per log reduction of B. pumilus spores, and the 260 nm LED unit required the lowest energy per order of reduction of MS2 coliphage. The combination of the 260 nm and 280 nm UV LED wavelengths was also evaluated for potential synergistic effects. No dual-wavelength synergy was detected for inactivation of

  6. Single-cell gel electrophoresis applied to the analysis of UV-C damage and its repair in human cells

    International Nuclear Information System (INIS)

    Gedik, C.M.; Collins, A.R.; Ewen, S.W.B.

    1992-01-01

    The authors have adapted procedure of single cell gel electrophoresis (SCGE) for studying DNA damage and repair induced by UV-C-radiation, using HeLa cells. UV-C itself does not induce DNA breakage, and though cellular repair of UV-C damage produces DNA breaks as intermediates, these are too short-lived to be detected by SCGE. Incubation of UV-C-irradiated cells with the DNA synthesis inhibitor aphidicolin causes accumulation of incomplete repair sites to a level readily detected by SCGE even after doses as low as 0.5 J m -2 and incubation for as little as 5 min. The authors also studied UV-C-dependent incision, repair synthesis and ligation in permeable cells. Finally, key incubated permeable cells, after UV-C-irradiation, with exogenous UV endonuclease, examined consequent breaks both by SCGE and by alkaline unwinding to express results of the electrophoretic method in terms of DNA break frequencies. The sensitivity of the SCGE technique can thus be estimated; as few as 0.1 DNA breaks per 10 9 daltons are detected. (Author)

  7. Detection of Explosives on Surfaces Using UV Raman Spectroscopy: Effect of Substrate Color

    Science.gov (United States)

    2017-10-01

    257.23-nm excitation (25 mW at the laser) using 2.5-s integration time and 100 accumulations. Each spectrum is offset by 400 counts from the one...tens of meters have been reported. The testing of UV Raman spectroscopy systems for standoff UV Raman spectroscopy has been generally limited to bare...SP2500A 500-mm focal length monochromator and a PIXIS 400 × 3048 pixel charge-coupled device (CCD) camera (Princeton Instruments, Trenton, NJ). An

  8. Antibodies to uv light denatured DNA in systemic lupus erythematosus: detection by filter radioimmunoassay and clinical correlations

    Energy Technology Data Exchange (ETDEWEB)

    Davis, P; Russell, A S; Percy, J S

    1976-12-01

    Antibodies to ultraviolet light denatured DNA (UV DNA) have been measured in patients with systemic lupus erythematosus (SLE) and normal subjects, using a millipore filter radioimmunoassay. High levels of UV DNA binding were only found in patients with SLE. The presence of UV DNA antibodies correlated well with the presence of native DNA antibodies, although immunodiffusion studies and inhibition techniques showed these antibodies to be immunologically distinct in many cases. Forty-one percent of the SLE patients had had photosensitivity at some stage of their disease, but there was a poor correlation between this symptom and the presence of UV DNA antibodies. Although UV DNA is known to be a potent immunogen, none of the results from this study suggests that antibodies to UV DNA are more than another example of the broad spectrum of antinuclear antibodies seen in SLE.

  9. SPECTROPHOTOMETRIC, ATOMIC ABSORPTION AND CONDUCTOMETRIC ANALYSIS OF TRAMADOL HYDROCHLORIDE

    Directory of Open Access Journals (Sweden)

    Sara M. Anis

    2011-09-01

    Full Text Available Six simple and sensitive spectroscopic and conductometric procedures (A-F were developed for the determination of tramadol hydrochloride. Methods A, B and C are based on the reaction of cobalt (II thiocyanate with tramadol to form a stable ternary complex, which could be measured by spectrophotometric (method A, atomic absorption (method B or conductometric (method C procedures. Methods D and E depend on the reaction of molybdenum thiocyanate with tramadol to form a stable ternary complex, measured by spectrophotometric means (method D or by atomic absorption procedures (method E, while method F depends on the formation of an ion pair complex between the studied drug and bromothymol blue which is extractable into methylene chloride. Tramadol hydrochloride could be assayed in the range of 80-560 and 40-–220 μg ml-1, 1-15 mg ml-1 and 2.5-22.5, 1.25-11.25 and 5-22 μg ml-1 using methods A,B,C,D,E and F, respectively. Various experimental conditions were studied. The results obtained showed good recoveries. The proposed procedures were applied successfully to the analysis of tramadol in its pharmaceutical preparations and the results were favorably comparable with the official method.

  10. A simple Ultraviolet spectrophotometric method for the determination of etoricoxib in dosage formulations

    Directory of Open Access Journals (Sweden)

    Shipra Singh

    2012-01-01

    Full Text Available The present study was undertaken to develop a validated, rapid, simple, and low-cost ultraviolet (UV spectrophotometric method for estimating Etoricoxib (ETX in pharmaceutical formulations. The analysis was performed on λ max 233 nm using 0.1 M HCl as blank/diluent. The proposed method was validated on International Conference on Harmonization (ICH guidelines including parameters as linearity, accuracy, precision, reproducibility, and specificity. The proposed method was also used to access the content of the ETX in two commercial brands of Indian market. Beer′s law was obeyed in concentration range of 0.1-0.5 μg/ml, and the regression equation was Y = 0.418x + 0.018. The mean accuracy values for 0.1 μg/ml and 0.2 μg/ml concentration of ETX were found to be 99.76 ± 0.52% and 99.12 ± 0.84, respectively, and relative standard deviation (RSD of interday and intraday was less than 2%. The developed method was suitable and specific to the analysis of ETX even in the presence of common excipients. The method was applied on two different marketed brands and ETX contents were 98.5 ± 0.56 and 99.33 ± 0.44, respectively, of labeled claim. The proposed method was validated as per ICH guidelines and statistically good results were obtained. This method can be employed for routine analysis of ETX in bulk and commercial formulations.

  11. A simple Ultraviolet spectrophotometric method for the determination of etoricoxib in dosage formulations.

    Directory of Open Access Journals (Sweden)

    S Singh

    2012-01-01

    Full Text Available The present study was undertaken to develop a validated, rapid, simple, and low-cost ultraviolet (UV spectrophotometric method for estimating Etoricoxib (ETX in pharmaceutical formulations. The analysis was performed on Î max 233 nm using 0.1 M HCl as blank/diluent. The proposed method was validated on International Conference on Harmonization (ICH guidelines including parameters as linearity, accuracy, precision, reproducibility, and specificity. The proposed method was also used to access the content of the ETX in two commercial brands of Indian market. Beer′s law was obeyed in concentration range of 0.1-0.5 μg/ml, and the regression equation was Y = 0.418x + 0.018. The mean accuracy values for 0.1 μg/ml and 0.2 μg/ml concentration of ETX were found to be 99.76 ± 0.52% and 99.12 ± 0.84, respectively, and relative standard deviation (RSD of interday and intraday was less than 2%. The developed method was suitable and specific to the analysis of ETX even in the presence of common excipients. The method was applied on two different marketed brands and ETX contents were 98.5 ± 0.56 and 99.33 ± 0.44, respectively, of labeled claim. The proposed method was validated as per ICH guidelines and statistically good results were obtained. This method can be employed for routine analysis of ETX in bulk and commercial formulations.

  12. Simultaneous in-line concentration for spectrophotometric determination of cations and anions

    Directory of Open Access Journals (Sweden)

    Rocha Fábio R. P

    2004-01-01

    Full Text Available A flow system is proposed for simultaneous in-line concentration of cations and anions. A sliding-bar commutator was employed to insert an anion and a cation exchange column into a flowing sample stream for serial retention of the analytes. In the injector alternative position, different solutions flowed through the columns for parallel elution of the species in different analytical paths. Three-way solenoid valves allowed the intermittent reagent introduction in the sample zones. Signals were measured by employing two flow-through LED-based detectors. The simultaneous retention of the sample zones in coiled reactors can be also performed to increase the residence time and the analyte conversion rate. The analytical potentiality was demonstrated by the in-line concentration of ammonium and phosphate followed by spectrophotometric detection. For a 90 s loading time, the sampling rate was estimated as 40 determinations per hour, which is three-fold higher than the obtained without performing the tasks simultaneously. Enrichment factors of 8.0 and 18 were estimated for phosphate and ammonium, respectively, yielding detection limits of 1 mg L-1 PO4(3- and 1 mg L-1 NH4+ (99.7% confidence level. The reagent consumption was lower than 2 mg per determination. Results for freshwater samples agreed with the obtained by reference APHA procedures at the 95% confidence level.

  13. Determination of vegetable tannins in tannery wastewater using RP-HPLC-technique with UV- and EC-detection; Bestimmung vegetabiler Gerbstoffe in Gerbereiabwasser unter Einsatz der RP-HPLC-Technik mit UV- und EC-Detektion

    Energy Technology Data Exchange (ETDEWEB)

    Zywicki, B.; Reemtsma, T.; Jekel, M. [Technische Univ. Berlin (Germany). Fachgebiet Wasserreinhaltung

    2001-07-01

    Numerous types of inorganic and organic environmental pollutants are encountered in leather tannery effluents. For reduction of the environmental impact of leather tanneries the substitution of chromium tanning agents by natural organic tanning agents (vegetable tannins) is discussed. The use of vegetable tannins leads to an elevated dissolved organic carbon content (DOC) in tannery effluent, even after biological treatment. Vegetable tannins may also be used as retanning agents, but they may, then interfere with precipitation of chromium. Therefore, an analytical method had to be established to estimate the total amount of vegetable tanning agents in the complex matrix of tannery wastewater. The analytical strategy for the determination of vegetable tannins in tannery effluents is to degrade the polyphenolic compounds by acid hydrolysis and to detect the resulting specific monomeric subunit gallic acid by RP-HPLC-technique with UV- and electrochemical detection (EC-detection). (orig.)

  14. A simple spectrophotometric determination of trace amounts of vanadium using thionin

    Directory of Open Access Journals (Sweden)

    Tom Cherian

    2005-12-01

    Full Text Available A simple and sensitive spectrophotometric method has been developed for the determination of trace amounts of vanadium using thionin as a chromogenic reagent. The proposed method is based on the reaction of vanadium(V with potassium iodide in acid medium to liberate iodine, which bleaches the violet colour of thionin and is measured at 600 nm. This decrease in absorbance is directly proportional to the vanadium(V concentration and obeys Beer's law in the range of 0.2-10 μgmL-1 of V(V. The molar absorptivity, Sandell's sensitivity, detection limit and quantitation limit of the method were found to be 2.298 x 104 Lmol-1cm-1, 0.52 x 10-2 μgcm-2, 0.035 μgmL-1 and 0.11 μgmL-1, respectively. The optimum reaction conditions and other analytical conditions were evaluated. The effect of interfering ions on the determination is described. The developed method has been successfully applied to the analysis of the vanadium in synthetic and alloy samples.

  15. A sensitive spectrophotometric determination of nitrogen dioxide in the working atmosphere

    Directory of Open Access Journals (Sweden)

    Prachi Parmar

    2009-12-01

    Full Text Available In the present investigation, a simple and sensitive spectrophotometric method for the determination of nitrogen dioxide in various environmental samples is described. Nitrogen dioxide in air was fixed as nitrite ion in alkaline sodium arsenite absorbing solution. The nitrite formed was diazotized with p−aminoacetophenone in acidic medium which was subsequently coupled with phloroglucinol to give yellow−orange dye in alkaline medium having an absorption maximum at 420 nm. Beer’s law was obeyed in the range of 0.008 − 0.12 μg mL-1 of nitrogen dioxide and has a molar absorptivity of 2.875 x 105 L mol-1 cm-1. Optimum reaction conditions for diazotization, full colour development and the effect of variables like temperature, time and pH have been studied. Detailed studies to check the collection efficiency and NO2:NO2- stoichiometric ratio has been carried out. The reaction has been successfully applied for the detection of nitrogen dioxide in cigarette smoke, scooter exhaust, and workroom air.

  16. 340 nm pulsed UV LED system for europium-based time-resolved fluorescence detection of immunoassays

    DEFF Research Database (Denmark)

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter

    2016-01-01

    We report on the design, development and investigation of an optical system based on UV light emitting diode (LED) excitation at 340 nm for time-resolved fluorescence detection of immunoassays. The system was tested to measure cardiac marker Troponin I with a concentration of 200 ng....../L in immunoassay. The signal-to-noise ratio was comparable to state-of-the-art Xenon flash lamp based unit with equal excitation energy and without overdriving the LED. We performed a comparative study of the flash lamp and the LED based system and discussed temporal, spatial, and spectral features of the LED...... excitation for time-resolved fluorimetry. Optimization of the suggested key parameters of the LED promises significant increase of the signal-to-noise ratio and hence of the sensitivity of immunoassay systems....

  17. 340 nm pulsed UV LED system for europium-based time-resolved fluorescence detection of immunoassays.

    Science.gov (United States)

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Petersen, Paul Michael; Pedersen, Christian

    2016-09-19

    We report on the design, development and investigation of an optical system based on UV light emitting diode (LED) excitation at 340 nm for time-resolved fluorescence detection of immunoassays. The system was tested to measure cardiac marker Troponin I with a concentration of 200 ng/L in immunoassay. The signal-to-noise ratio was comparable to state-of-the-art Xenon flash lamp based unit with equal excitation energy and without overdriving the LED. We performed a comparative study of the flash lamp and the LED based system and discussed temporal, spatial, and spectral features of the LED excitation for time-resolved fluorimetry. Optimization of the suggested key parameters of the LED promises significant increase of the signal-to-noise ratio and hence of the sensitivity of immunoassay systems.

  18. Spectrophotometric determination of trace uranium in phosphate ore samples from kurum and uro areas, Nuba mountains, Sudan

    International Nuclear Information System (INIS)

    Mohamed, A. A.; Ali, A. H.; Altayeb, M. A. H.

    2004-01-01

    A method was proposed for the spectrophotometric determination of uranium content in phosphate ores. the method is based on the use of nitrogen (v) acid for leaching the rock, and treatment with ammonium carbonate solution, whereby uranium (Vi) is kept in solution as its carbonate complex. The ion-exchange technique was used for the recovery of uranium. Uranium was determined spectrophotometrically by measurement of the absorbance of the yellow uranium (Vi)-8-hydroxyquinolate complex at λ 425 nm. The procedure was used for the determination of trace uranium content in 30 phosphate ore samples collected from Kurun and Uro areas in Nuba mountains in Sudan. X-ray fluorescence technique was employed for the assessment of the method used. The spectrophotometric method results show a high similarity with those obtained by XRF technique. This agreement indicates that the procedure proposed here has been successfully applied for the determination of uranium in phosphate ores. (Author)

  19. Spectro-photometric determination of niobium in Nb-Ti alloy using in-situ separation of Ti by masking with H3PO4

    International Nuclear Information System (INIS)

    Ghosh, Prasun; Dutta, M.; Jat, J.R.; Reddy, G.B.; Balaji Rao, Y.; Subba Rao, Y.

    2016-01-01

    The present paper details a simple procedure for the determination of Nb content in Nb-Ti alloy. The method involves dissolution of alloy in mixture of HNO 3 and HF followed by fuming with H 2 SO 4 . Subsequently, solution is taken for UV-Vis Spectro-photometric measurement after addition of Conc. H 3 PO 4 and H 2 O 2 . Hydrogen peroxide is added as coloring agent. Hydrogen peroxide (H 2 O 2 ) is known to form yellow color peroxo complex with both Niobium and Titanium in sulfuric acid medium and thus Ti will interfere with Nb in absorbance measurement. In view of this practical difficulty, in-situ separation of Ti during measurement has been resorted by masking Ti using Conc. H 3 PO 4 . Standard synthetic sample solution of Nb-Ti was prepared having Niobium and titanium in the ratio of 60:40, 50:50 and 40:60. Quantitative measurement of Niobium was carried out by UV-Visible spectrophotometer at 365 nm. The interference of titanium is prominent from the obtained Niobium concentration. Different ratios of H 3 PO 4 and H 2 SO 4 tried to arrive at optimum ratio to eliminate titanium interference and results are as shown. Quantitative measurement of Niobium was carried out at 355 nm as absorption maxima shifted from 365 nm to 355 nm in presence of phosphoric acid. Results show a good agreement with synthetic standard at 80:20 sulfuric to phosphoric acid ratio

  20. Spectrophotometric determination of thorium using arsenazo III in water

    International Nuclear Information System (INIS)

    Rio, M.A.P. do; Godoy, J.M. de.

    1985-01-01

    A spectrophotometric determination of thorium with arsenazo III (1,8 dihidroxynaphtaline - 3,6 sulfanic acid - 2,7 bis (azo-2) - phenil argonic acid) was carried out aiming to analyse this element in water. In order to eliminate possible interferences, a coprecipitation with lantanium fluoride was used followed by an extration with 0,2 M TTA (tenoil-trifluor - aceton) / Benzen. The results showed a good agreement with the ones obtained by alfa-spectrometry. (Author) [pt

  1. Spectrophotometric determination of dopaminergic drugs used for Parkinson's disease, cabergoline and ropinirole, in pharmaceutical preparations.

    Science.gov (United States)

    Onal, Armağan; Cağlar, Sena

    2007-04-01

    Simple and reproducible spectrophotometric methods have been developed for determination of dopaminergic drugs used for Parkinson's disease, cabergoline (CAB) and ropinirole hydrochloride (ROP), in pharmaceutical preparations. The methods are based on the reactions between the studied drug substances and ion-pair agents [methyl orange (MO), bromocresol green (BCG) and bromophenol blue (BPB)] producing yellow colored ion-pair complexes in acidic buffers, after extracting in dichloromethane, which are spectrophotometrically determined at the appropriate wavelength of ion-pair complexes. Beer's law was obeyed within the concentration range from 1.0 to 35 microg ml(-1). The developed methods were applied successfully for the determination of these drugs in tablets.

  2. Kinetic spectrophotometric determination of trace amounts of selenium and vanadium

    Energy Technology Data Exchange (ETDEWEB)

    Safavi, A.; Sedghy, H.R.; Shams, E. [Dept. of Chemistry, Shiraz Univ. (Iran)

    1999-11-01

    A sensitive kinetic spectrophotometric method has been developed for the determination of Se(IV) over the range of 45 to 4000 ng in 10 mL of solution. The method is based on the catalytic effect of Se(IV) on the reduction reaction of bromate by hydrazinium dichloride, with subsequent reaction of Ponceau S with products of the above reaction (chlorine and bromine), causing color changing of Ponceau S. Method development includes optimization of time interval for measurement of slope, pH, reagents concentration, and temperature. The optimized conditions yielded a theoretical detection limit of 33 ng/10 mL of solution of Se(IV). The interfering effects were studied and removed. The method was applied to the determination of selenium in spiked water, Kjeldahl tablet, selenium tablet, and shampoo. Vanadium(V) has an inhibition effect on the catalyzed reaction of bromate and hydrazine by selenium. Using this effect, V(V) can be determined in the range of 70 to 2500 ng in 10 mL of solution. The optimization procedure includes pH and selenium concentration. An extraction method was used for interference removal. The method was applied to the determination of vanadium in petroleum. (orig.)

  3. Autofluorescence of pigmented skin lesions using a pulsed UV laser with synchronized detection: clinical results

    Science.gov (United States)

    Cheng, Haynes P. H.; Svenmarker, Pontus; Xie, Haiyan; Tidemand-Lichtenberg, Peter; Jensen, Ole B.; Bendsoe, Niels; Svanberg, Katarina; Petersen, Paul Michael; Pedersen, Christian; Andersson-Engels, Stefan; Andersen, Peter E.

    2010-04-01

    We report preliminary clinical results of autofluorescence imaging of malignant and benign skin lesions, using pulsed 355 nm laser excitation with synchronized detection. The novel synchronized detection system allows high signal-tonoise ratio to be achieved in the resulting autofluorescence signal, which may in turn produce high contrast images that improve diagnosis, even in the presence of ambient room light. The synchronized set-up utilizes a compact, diode pumped, pulsed UV laser at 355 nm which is coupled to a CCD camera and a liquid crystal tunable filter. The excitation and image capture is sampled at 5 kHz and the resulting autofluorescence is captured with the liquid crystal filter cycling through seven wavelengths between 420 nm and 580 nm. The clinical study targets pigmented skin lesions and evaluates the prospects of using autofluorescence as a possible means in differentiating malignant and benign skin tumors. Up to now, sixteen patients have participated in the clinical study. The autofluorescence images, averaged over the exposure time of one second, will be presented along with histopathological results. Initial survey of the images show good contrast and diagnostic results show promising agreement based on the histopathological results.

  4. AAS and spectrophotometric determination of propranolol HCl and metoprolol tartrate.

    Science.gov (United States)

    El-Ries, M A; Abou Attia, F M; Ibrahim, S A

    2000-12-15

    Two simple and accurate spectrophotometric methods are described for the determination of propranolol hydrochloride (I) and metoprolol tartrate (II). The methods are based on the reaction of each drug as a secondary amine: (a) with carbon disulphide, the formed complex extracted into iso-butyl methyl ketone (IBMK) after chelation with Cu(II) ions at pH 7.5, followed by measuring the absorbance at 435.4 nm or indirectly for the drug by flame atomic absorption spectrophotometry (AAS). The calibration graph is linear up to 40 and 60 microg ml(-1) with apparent molar absorptivities of 6.89 x 10(3) and 1.08 x 104 l mol(-1) cm(-1) and correlation coefficients of 0.9994 and 0.9995 for propranolol and metoprolol, respectively; (b) with pi-acceptors, tetracyanoethylene (TCNE), or chloranilic acid (CLA) to give highly coloured complex species. The coloured products are quantitated spectrophotometrically at 415 or 510 nm for the two drugs with TCNE and CLA, respectively, and obey Beer's Law with RSD less than 2.0. The methods were applied to the determination of these drugs in pharmaceutical preparation without interferences.

  5. Detection and repair of a UV-induced photosensitive lesion in the DNA of human cells

    International Nuclear Information System (INIS)

    Francis, A.A.; Regan, J.D.

    1986-01-01

    Irradiation with UV light results in damage to the DNA of human cells. The most numerous lesions are pyrimidine dimers; however, other lesions are known to occur and may contribute to the overall deleterious effect of UV irradiation. The authors have observed evidence of a UV-induced lesion other than pyrimidine dimers in the DNA of human cells by measuring DNA strand breaks induced by irradiating with 313-nm light following UV (254-nm) irradiation. The data suggest that, in normal cells, the lesion responsible for this effect is rapidly repaired or altered; whereas, in xeroderma pigmentosum variant cells it seems to remain unchanged. Some change apparently occurs in the DNA of xeroderma pigmentosum group A cells which results in an increase in photolability. These data indicate a deficiency in DNA repair of xeroderma pigmentosum variant cells as well as in xeroderma pigmentosum group A cells. (Auth.)

  6. Quality assessment of solar UV irradiance measured with array spectroradiometers

    Science.gov (United States)

    Egli, Luca; Gröbner, Julian; Hülsen, Gregor; Bachmann, Luciano; Blumthaler, Mario; Dubard, Jimmy; Khazova, Marina; Kift, Richard; Hoogendijk, Kees; Serrano, Antonio; Smedley, Andrew; Vilaplana, José-Manuel

    2016-04-01

    The reliable quantification of ultraviolet (UV) radiation at the earth's surface requires accurate measurements of spectral global solar UV irradiance in order to determine the UV exposure to human skin and to understand long-term trends in this parameter. Array spectroradiometers (ASRMs) are small, light, robust and cost-effective instruments, and are increasingly used for spectral irradiance measurements. Within the European EMRP ENV03 project "Solar UV", new devices, guidelines and characterization methods have been developed to improve solar UV measurements with ASRMs, and support to the end user community has been provided. In order to assess the quality of 14 end user ASRMs, a solar UV intercomparison was held on the measurement platform of the World Radiation Center (PMOD/WRC) in Davos, Switzerland, from 10 to 17 July 2014. The results of the blind intercomparison revealed that ASRMs, currently used for solar UV measurements, show a large variation in the quality of their solar UV measurements. Most of the instruments overestimate the erythema-weighted UV index - in particular at large solar zenith angles - due to stray light contribution in the UV-B range. The spectral analysis of global solar UV irradiance further supported the finding that the uncertainties in the UV-B range are very large due to stray light contribution in this wavelength range. In summary, the UV index may be detected by some commercially available ASRMs within 5 % compared to the world reference spectroradiometer, if well characterized and calibrated, but only for a limited range of solar zenith angles. Generally, the tested instruments are not yet suitable for solar UV measurements for the entire range between 290 and 400 nm under all atmospheric conditions.

  7. Single Chip EUV, VUV and Deep UV Photodetector System with Integrated Amplifier, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We here propose the development and fabrication of an integrated sensor device capable of detecting across a wide band of UV radiation, from extreme UV (1 to 50 nm)...

  8. Reichardt's dye and its reactions with the alkylating agents 4-chloro-1-butanol, ethyl methanesulfonate, 1-bromobutane and Fast Red B - a potentially useful reagent for the detection of genotoxic impurities in pharmaceuticals.

    Science.gov (United States)

    Corrigan, Damion K; Whitcombe, Michael J; McCrossen, Sean; Piletsky, Sergey

    2009-04-01

    Alkylating agents are potentially genotoxic impurities that may be present in drug products. These impurities occur in pharmaceuticals as by-products from the synthetic steps involved in drug production, as impurities in starting materials or from in-situ reactions that take place in the final drug product. Currently, analysis for genotoxic impurities is typically carried out using either HPLC/MS or GC/MS. These techniques require specialist expertise, have long analysis times and often use sample clean-up procedures. Reichardt's dye is well known for its solvatochromic properties. In this paper the dye's ability to undergo alkylation is reported. The reaction between Reichardt's dye and alkylating agents such as 4-chloro-1-butanol and ethyl methanesulfonate was monitored spectrophotometrically at 618 nm in acetonitrile and 624 nm in N,N-dimethylformamide. Changes in absorption were observed using low levels of alkylating agent (5-10 parts per million). Alkylation of the dye with 4-chloro-1-butanol and ethyl methanesulfonate was confirmed. Reichardt's dye, and its changing UV absorption, was examined in the presence of paracetamol (10 and 100 mg/ml). Whilst the alkylation-induced changes in UV absorption were not as pronounced as with standard solutions, detection of alkylation was still possible. Using standard solutions and in the presence of a drug matrix, Reichardt's dye shows promise as a reagent for detection of low levels of industrially important alkylating agents.

  9. Determination of the acidity constants of neutral red and bromocresol green by solution scanometric method and comparison with spectrophotometric results

    Directory of Open Access Journals (Sweden)

    Ardeshir Shokrollahi

    2016-03-01

    The method is based on scanning cells containing the indicator solution with a scanner, and analyzing the color of each cell with a software written in visual basic (VB 6 media to red, green and blue values. The cells were made by making holes in the Plexiglas® sheet. Also, the acidity constants of the neutral red and bromocresol green indicators were studied with spectrophotometrically. HypSpec program has been applied for the estimation of pKa values based on spectrophotometric data. The agreement between obtained pKa values by solution scanometric, spectrophotometric method and values reported in the literature demonstrates the utility of the method here used. Also the HySS 2009 program was applied for drawing of the corresponding distribution diagrams.

  10. [Photoionization ion mobility spectrometry (UV-IMS) for the isomeric volatile organic compounds].

    Science.gov (United States)

    Li, Hu; Niu, Wen-qi; Wang, Hong-mei; Huang, Chao-qun; Jiang, Hai-he; Chu, Yan-nan

    2012-01-01

    The construction and performance study is reported for a newly developed ultraviolet photoionization ion mobility spectrometry (UV-IMS). In the present paper, an UV-IMS technique was firstly developed to detect eleven isomeric volatile organic compounds including the differences in the structure of carbon chain, the style of function group and the position of function group. Their reduced mobility values were determined and increased in this order: linears alcohols homemade UV-IMS was around ppb-ppm.

  11. Sensitive spectrophotometric determination of aceclofenac following azo dye formation with 4-carboxyl-2,6-dinitrobenzene diazonium ion.

    Science.gov (United States)

    Aderibigbe, Segun A; Adegoke, Olajire A; Idowu, Olakunle S; Olaleye, Sefiu O

    2012-01-01

    The study is a description of a sensitive spectrophotometric determination of aceclofenac following azo dye formation with 4-carboxyl-2,6-dinitrobenzenediazonium ion (CDNBD). Spot test and thin layer chromatography revealed the formation of a new compound distinct from CDNBD and aceclofenac. Optimization studies established a reaction time of 5 min at 30 degrees C after vortex mixing the drug/CDNBD for 10 s. An absorption maximum of 430 nm was selected as analytical wavelength. A linear response was observed over 1.2-4.8 μg/mL of aceclofenac with a correlation coefficient of 0.9983 and the drug combined with CDNBD at stoichiometric ratio of 2 : 1. The method has a limit of detection of 0.403 μg/mL, limit of quantitation of 1.22 μg/mL and is reproducible over a three day assessment. The method gave Sandell's sensitivity of 3.279 ng/cm2. Intra- and inter-day accuracies (in terms of errors) were less than 6% while precisions were of the order of 0.03-1.89% (RSD). The developed spectrophotometric method is of equivalent accuracy (p > 0.05) with British Pharmacopoeia, 2010 potentiometric method. It has the advantages of speed, simplicity, sensitivity and more affordable instrumentation and could found application as a rapid and sensitive analytical method of aceclofenac. It is the first described method by azo dye derivatization for the analysis of aceclofenac in bulk samples and dosage forms.

  12. Spectrophotometric determination and thermodynamic studies of the charge transfer complexation of emedastine difumarate with some π-acceptors

    Directory of Open Access Journals (Sweden)

    Abdel-Raeq A. Sawsan

    2017-05-01

    Full Text Available Spectrophotometric procedures were presented for the determination of antihistaminic drug, emedastine difumarate. The methods are based on the charge transfer complexation reaction of the drug with π-acceptors; 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ, chloranilic acid (CA and 7,7,8,8-tetracyanoquinodimethane (TCNQ. Different charge-transfer complexes and colored radical anions were obtained. The formations of the colored complexes were utilized in the development of simple, rapid and accurate spectrophotometric methods for the analysis of emedastine in drug substance and products. Under the optimum reaction conditions, linear relationships with good correlation coefficients (0.9996–0.9999 were found between the absorbance at the relevant maxima and the concentrations of emedastine in the range of 0.8–200 μg mL−1. The limits of detection ranged from 0.06 to 0.76 μg mL−1. The molar absorptivities and association constants for the colored complexes were evaluated using the Benesi–Hildebrand equation. The free energy change (ΔG° and the enthalpy of formation (ΔH° as well as the entropy (ΔS° were also determined. The methods were successfully applied to analyze the drug formulation with mean recovery percentages ± RSD% of 100.04 ± 0.59–100.22 ± 0.72. The results were compared favorably with the official and reported methods.

  13. Complexation equilibria and spectrophotometric determination of iron(III) with 1-amino-4-hydroxyanthraquinone.

    Science.gov (United States)

    Abu-Bakr, M S; Sedaira, H; Hashem, E Y

    1994-10-01

    The complex equilibria of iron(III) with 1-amino-4-hydroxyanthraquinone (AMHA) were studied spectrophotometrically in 40% (v/v) ethanol and an ionic strength of 0.1M (NaClO(4)). The complexation reactions were demonstrated and characterized using graphical logarithmic analysis of the absorbance-pH graphs. A simple, rapid, selective and sensitive method for the spectrophotometric determination of trace amounts of Fe(III) is developed based on the formation of Fe(AMHA) complex at pH 2.5 (lambda(max) = 640 nm, epsilon approximately = 2.1 x 10(4) L. mol(-1) . cm(-1)) in the presence of a large number of foreign ions. Interferences caused by palladium(II) was masked by the addition of cyanide ions. The method has been applied to the determination of iron in some synthetic samples and polymetallic iron ores.

  14. Advances in analytical methods and occurrence of organic UV-filters in the environment — A review

    International Nuclear Information System (INIS)

    Ramos, Sara; Homem, Vera; Alves, Arminda; Santos, Lúcia

    2015-01-01

    UV-filters are a group of compounds designed mainly to protect skin against UVA and UVB radiation, but they are also included in plastics, furniture, etc., to protect products from light damage. Their massive use in sunscreens for skin protection has been increasing due to the awareness of the chronic and acute effects of UV radiation. Some organic UV-filters have raised significant concerns in the past few years for their continuous usage, persistent input and potential threat to ecological environment and human health. UV-filters end up in wastewater and because wastewater treatment plants are not efficient in removing them, lipophilic compounds tend to sorb onto sludge and hydrophilics end up in river water, contaminating the existing biota. To better understand the risk associated with UV-filters in the environment a thorough review regarding their physicochemical properties, toxicity and environmental degradation, analytical methods and their occurrence was conducted. Higher UV-filter concentrations were found in rivers, reaching 0.3 mg/L for the most studied family, the benzophenone derivatives. Concentrations in the ng to μg/L range were also detected for the p-aminobenzoic acid, cinnamate, crylene and benzoyl methane derivatives in lake and sea water. Although at lower levels (few ng/L), UV-filters were also found in tap and groundwater. Swimming pool water is also a sink for UV-filters and its chlorine by-products, at the μg/L range, highlighting the benzophenone and benzimidazole derivatives. Soils and sediments are not frequently studied, but concentrations in the μg/L range have already been found especially for the benzophenone and crylene derivatives. Aquatic biota is frequently studied and UV-filters are found in the ng/g-dw range with higher values for fish and mussels. It has been concluded that more information regarding UV-filter degradation studies both in water and sediments is necessary and environmental occurrences should be monitored more

  15. Advances in analytical methods and occurrence of organic UV-filters in the environment — A review

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Sara; Homem, Vera, E-mail: vhomem@fe.up.pt; Alves, Arminda; Santos, Lúcia

    2015-09-01

    UV-filters are a group of compounds designed mainly to protect skin against UVA and UVB radiation, but they are also included in plastics, furniture, etc., to protect products from light damage. Their massive use in sunscreens for skin protection has been increasing due to the awareness of the chronic and acute effects of UV radiation. Some organic UV-filters have raised significant concerns in the past few years for their continuous usage, persistent input and potential threat to ecological environment and human health. UV-filters end up in wastewater and because wastewater treatment plants are not efficient in removing them, lipophilic compounds tend to sorb onto sludge and hydrophilics end up in river water, contaminating the existing biota. To better understand the risk associated with UV-filters in the environment a thorough review regarding their physicochemical properties, toxicity and environmental degradation, analytical methods and their occurrence was conducted. Higher UV-filter concentrations were found in rivers, reaching 0.3 mg/L for the most studied family, the benzophenone derivatives. Concentrations in the ng to μg/L range were also detected for the p-aminobenzoic acid, cinnamate, crylene and benzoyl methane derivatives in lake and sea water. Although at lower levels (few ng/L), UV-filters were also found in tap and groundwater. Swimming pool water is also a sink for UV-filters and its chlorine by-products, at the μg/L range, highlighting the benzophenone and benzimidazole derivatives. Soils and sediments are not frequently studied, but concentrations in the μg/L range have already been found especially for the benzophenone and crylene derivatives. Aquatic biota is frequently studied and UV-filters are found in the ng/g-dw range with higher values for fish and mussels. It has been concluded that more information regarding UV-filter degradation studies both in water and sediments is necessary and environmental occurrences should be monitored more

  16. Zeolite - a possible substitute of silica gel in spectrophotometric determination of uranium?

    International Nuclear Information System (INIS)

    Foeldesova, M; Dillinger, P.

    2006-01-01

    Zeolites sorption abilities differ from the ones of the silica gel, which is normally used for uranium determination by spectrophotometric method. The difference is obvious mainly in the case of zeolites chemically modified with 1 or 2 mol/L NaOH solution. Absorbances measured using these zeolites on an radioactive water samples were 4 to 4.2 times bigger than the ones with silica gel. This avoids a use of one universal calibration curve for experimental data evaluation. Within delivered experimental data only a calibration curve for silica gel was provided. Its application to zeolites caused substantial misinterpretation of the results. Calculational construction of individual calibration curves made at this work shaw, that zeolites have a potential to replace the silica gel. This possibility is necessary to confirm by more experiments. Better sorption abilities of the modified zeolites would be utilized to reduce the lower limit for uranium determination by spectrophotometric method. (authors)

  17. Liquid chromatographic and ultraviolet spectrophotometric determination of bevantolol and hydrochlorothiazide in feeds.

    Science.gov (United States)

    Spurlock, C H; Schneider, H G

    1984-01-01

    Separate assay methods have been developed for the 2 components of an 80 + 20 drug blend of bevantolol and hydrochlorothiazide (HCT) in admixtures with animal feed. Drug/diet admixtures are extracted with methanol for reverse phase ion-pair liquid chromatographic (LC) assay of bevantolol, and with acetonitrile for ultraviolet spectrophotometric assay of HCT. Bevantolol, a cardioselective beta blocker, is separated from soluble feed components with an RP-18 column, using methanol-water-acetic acid (60 + 40 + 1) containing 0. 005M octane-sulfonic acid, sodium salt, as ion-pairing reagent. HCT is determined spectrophotometrically in acetonitrile extracts, using a suitable blank extract as reference. Average recovery of HCT from an admixture of 0.5 mg blend/g diet is 94.5% +/- 4.3 RSD and at 2.0 mg/g, 101.5% +/- 3.5 RSD. Bevantolol recovery from the same admixtures is 101.8% +/- 2.7 RSD and 99.0% +/- 3.5 RSD, respectively, using the method as described.

  18. Simultaneous spectrophotometric determination of uranium and zirconium using cloud point extraction and multivariate methods

    International Nuclear Information System (INIS)

    Ghasemi, Jahan B.; Hashemi, Beshare; Shamsipur, Mojtaba

    2012-01-01

    A cloud point extraction (CPE) process using the nonionic surfactant Triton X-114 to simultaneous extraction and spectrophotometric determination of uranium and zirconium from aqueous solution using partial least squares (PLS) regression is investigated. The method is based on the complexation reaction of these cations with Alizarin Red S (ARS) and subsequent micelle-mediated extraction of products. The chemical parameters affecting the separation phase and detection process were studied and optimized. Under the optimum experimental conditions (i.e. pH 5.2, Triton X-114 = 0.20%, equilibrium time 10 min and cloud point 45 C), calibration graphs were linear in the range of 0.01-3 mg L -1 with detection limits of 2.0 and 0.80 μg L -1 for U and Zr, respectively. The experimental calibration set was composed of 16 sample solutions using an orthogonal design for two component mixtures. The root mean square error of predictions (RMSEPs) for U and Zr were 0.0907 and 0.1117, respectively. The interference effect of some anions and cations was also tested. The method was applied to the simultaneous determination of U and Zr in water samples.

  19. Spectrophotometric retinal oximetry in pigs

    DEFF Research Database (Denmark)

    Traustason, Sindri; Kiilgaard, Jens Folke; Karlsson, Robert

    2013-01-01

    PURPOSE: To assess the validity of spectrophotometric retinal oximetry, by comparison to blood gas analysis and intra-vitreal measurements of partial pressure of oxygen (pO2). METHODS: Female domestic pigs were used for all experiments (n=8). Oxygen fraction in inspired air was changed using...... a mixture of room air, pure oxygen and pure nitrogen, ranging from 5% to 100% oxygen. Femoral arterial blood gas analysis and retinal oximetry was performed at each level of inspiratory oxygen fraction. Retinal oximetry was performed using a commercial instrument, the Oxymap Retinal Oximeter T1 (Oxymap ehf...... arterial oxygen saturation and the optical density ratio over retinal arteries revealed an approximately linear relationship (R(2) = 0.74, p = 3.4 x 10(-9)). In order to test the validity of applying the arterial calibration to veins, we compared non-invasive oximetry measurements to invasive pO2...

  20. Comparative study on the selectivity of various spectrophotometric techniques for the determination of binary mixture of fenbendazole and rafoxanide.

    Science.gov (United States)

    Saad, Ahmed S; Attia, Ali K; Alaraki, Manal S; Elzanfaly, Eman S

    2015-11-05

    Five different spectrophotometric methods were applied for simultaneous determination of fenbendazole and rafoxanide in their binary mixture; namely first derivative, derivative ratio, ratio difference, dual wavelength and H-point standard addition spectrophotometric methods. Different factors affecting each of the applied spectrophotometric methods were studied and the selectivity of the applied methods was compared. The applied methods were validated as per the ICH guidelines and good accuracy; specificity and precision were proven within the concentration range of 5-50 μg/mL for both drugs. Statistical analysis using one-way ANOVA proved no significant differences among the proposed methods for the determination of the two drugs. The proposed methods successfully determined both drugs in laboratory prepared and commercially available binary mixtures, and were found applicable for the routine analysis in quality control laboratories. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. UV Visibility of Moderate-Redshift Giant Elliptical Galaxies

    Directory of Open Access Journals (Sweden)

    Myung-Hyun Rhee

    1998-06-01

    Full Text Available We show quantitatively whether giant elliptical galaxies would be visible at far UV wavelengths if they were placed at moderate redshift of 0.4-0.5. On the basis of simple cosmological tests, we conclude that giant elliptical galaxies can be detectable upto the redshift of 0.4-0.5 in the proposed GALEX (Galaxy Evolution Explorer Deep Imaging Survey. We also show that obtaining UV color index such as m_1550 - V from upcoming GALEX and SDSS (Sloan Digital Sky Survey observations should be feasible.

  2. Dual-wavelength β-correction spectrophotometric determination of trace concentrations of cyanide ions based on the nucleophilic addition of cyanide to imine group of the new reagent 4-hydroxy-3-(2-oxoindolin-3-ylideneamino)-2-thioxo-2H-1,3-thiazin-6(3H)-one

    International Nuclear Information System (INIS)

    Hamza, A.; Bashammakh, A.S.; Al-Sibaai, A.A.; Al-Saidi, H.M.; El-Shahawi, M.S.

    2010-01-01

    A simple, fast, low cost and sensitive direct β-correction spectrophotometric assay of cyanide ions based on its reaction with the reagent 4-hydroxy-3-(2-oxoindolin-3-ylideneamino)-2-thioxo-2H-1, 3-thiazin-6(3H)-one, abbreviated as HOTT in aqueous media of pH 7-10 is described. The electronic spectrum of the produced brown-red colored species showed well defined and sharp peak at λ max = 466 nm. The effective molar absorptivity for the produced cyano compound was 2.5 x 10 4 L mol -1 cm -1 . Beer's law and Ringbom's plots were obeyed in the concentration range 0.05-2.0 and 0.30-1.5 μg mL -1 cyanide ions, respectively. The proposed method offers 16.0 and 50.3 μg L -1 lower limits of detection (LOD) and quantification (LOQ) of the cyanide ion, respectively. The analytical utility of the method for the analysis of cyanide ions in tap and drinking water samples was demonstrated and the results were compared successfully with the conventional cyanide ion selective electrode. The short time response and the detection by the naked eye make the method available for the detection and quantitative determination of cyanide in a variety of samples e.g. fresh and drinking water. Moreover, the structure of the produced colored species was determined with the aid of spectroscopic measurements (UV-Vis, IR, 1 H and 13 C NMR) and elemental analysis.

  3. Spectrophotometric Method for the Determination of Atmospheric Cr Pollution as a Factor to Accelerated Corrosion

    Directory of Open Access Journals (Sweden)

    Dereje Homa

    2017-01-01

    Full Text Available The effect of Cr(VI pollution on the corrosion rate of corrugated iron roof samples collected from tanning industry areas was investigated through simulated laboratory exposure and spectrophotometric detection of Cr(III deposit as a product of the reaction. The total level of Cr detected in the samples ranged from 113.892 ± 0.17 ppm to 53.05 ± 0.243 ppm and showed increasing trend as sampling sites get closer to the tannery and in the direction of tannery effluent stream. The laboratory exposure of a newly manufactured material to a simulated condition showed a relatively faster corrosion rate in the presence of Cr(VI with concomitant deposition of Cr(III under pH control. A significant (P = 0.05 increase in the corrosion rate was also recorded when exposing scratched or stress cracked samples. A coupled redox process where Cr(VI is reduced to a stable, immobile, and insoluble Cr(III accompanying corrosion of the iron is proposed as a possible mechanism leading to the elevated deposition of the latter on the materials. In conclusion, the increased deposits of Cr detected in the corrugated iron roof samples collected from tanning industry zones suggested possible atmospheric Cr pollution as a factor to the accelerated corrosion of the materials.

  4. Spectrophotometric Method for the Determination of Atmospheric Cr Pollution as a Factor to Accelerated Corrosion.

    Science.gov (United States)

    Homa, Dereje; Haile, Ermias; Washe, Alemayehu P

    2017-01-01

    The effect of Cr(VI) pollution on the corrosion rate of corrugated iron roof samples collected from tanning industry areas was investigated through simulated laboratory exposure and spectrophotometric detection of Cr(III) deposit as a product of the reaction. The total level of Cr detected in the samples ranged from 113.892 ± 0.17 ppm to 53.05 ± 0.243 ppm and showed increasing trend as sampling sites get closer to the tannery and in the direction of tannery effluent stream. The laboratory exposure of a newly manufactured material to a simulated condition showed a relatively faster corrosion rate in the presence of Cr(VI) with concomitant deposition of Cr(III) under pH control. A significant ( P = 0.05) increase in the corrosion rate was also recorded when exposing scratched or stress cracked samples. A coupled redox process where Cr(VI) is reduced to a stable, immobile, and insoluble Cr(III) accompanying corrosion of the iron is proposed as a possible mechanism leading to the elevated deposition of the latter on the materials. In conclusion, the increased deposits of Cr detected in the corrugated iron roof samples collected from tanning industry zones suggested possible atmospheric Cr pollution as a factor to the accelerated corrosion of the materials.

  5. A study of pH-dependent photodegradation of amiloride by a multivariate curve resolution approach to combined kinetic and acid-base titration UV data.

    Science.gov (United States)

    De Luca, Michele; Ioele, Giuseppina; Mas, Sílvia; Tauler, Romà; Ragno, Gaetano

    2012-11-21

    Amiloride photostability at different pH values was studied in depth by applying Multivariate Curve Resolution Alternating Least Squares (MCR-ALS) to the UV spectrophotometric data from drug solutions exposed to stressing irradiation. Resolution of all degradation photoproducts was possible by simultaneous spectrophotometric analysis of kinetic photodegradation and acid-base titration experiments. Amiloride photodegradation showed to be strongly dependent on pH. Two hard modelling constraints were sequentially used in MCR-ALS for the unambiguous resolution of all the species involved in the photodegradation process. An amiloride acid-base system was defined by using the equilibrium constraint, and the photodegradation pathway was modelled taking into account the kinetic constraint. The simultaneous analysis of photodegradation and titration experiments revealed the presence of eight different species, which were differently distributed according to pH and time. Concentration profiles of all the species as well as their pure spectra were resolved and kinetic rate constants were estimated. The values of rate constants changed with pH and under alkaline conditions the degradation pathway and photoproducts also changed. These results were compared to those obtained by LC-MS analysis from drug photodegradation experiments. MS analysis allowed the identification of up to five species and showed the simultaneous presence of more than one acid-base equilibrium.

  6. Spectrophotometric determination of Sn+2 in lyophilized kit for labeling with 99mTc

    International Nuclear Information System (INIS)

    Araujo, Elaine Bortoleti; Sampel, Carolina Judith; Melo, Ivani Bortoleti; Okamoto, Miriam R.Y; Silva, Constancia P.G

    2004-01-01

    The preparation of 99 mTc labeled radiopharmaceuticals depends on the reduction of the technetium pertechnetate, commonly by stannous chloride (SnCl 2 ). The determination of the Sn +2 contents in the lyophilized preparations represents an important quality control procedure that may be applied to the process and to the final product. The objective os this work is the optimization of an spectrophotometric assay to the determination os Sn +2 contents in a citrate-stannous lyophilized kit for 99 mTc labeling. The spectrophotometric methodology employed is based in the colour development when Sn +2 reacts with sodium molybdate in the presence of potasium thiocyanate in chloridric medium. The colourfull reaction studied showed high stability after 60 minutes of the mixtures preparation. The sequence of reagents introduction in the reaction mixture was determinant to the assay. The molibdenium-stannous-tiocianate sequence produces calibration curves with good correlations (R2 ≥ 0.99). The concentrations of the molibdenium solution was also studied, in order to determine a ideal concentration for the Sn +2 range. The spectrophotometric method studied was usefull to the determination of Sn +2 content in different batches of citrate-stannous preparations. The method was fast and easy and can be applied to different stages of the production process, in order to guarantee the content of Sn +2 in the preparations (Au)

  7. Covalent dimerization of ribulose bisphosphate carboxylase subunits by UV radiation

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, R.M.B. [Universidade Tecnica, Lisbon (Portugal). Inst. Superior de Agronomia]|[Universidade Nova de Lisboa, Oeiras (Portugal). Instituto de Tecnologia Quimica e Biologica; Franco, E.; Teixeira, A.R.N. [Universidade Tecnica, Lisbon (Portugal). Inst. Superior de Agronomia

    1996-08-15

    The effect of UV radiation (UV-A, UV-B and UV-C) on ribulose bisphosphate carboxylase from a variety of plant species was examined. The exposition of plant leaves or the pure enzyme to UV radiation produced a UV-dependent accumulation of a 65 kDa polypeptide (P65). Different approaches were utilized to elucidate the origin and structure of P65: electrophoretic and fluorographic analyses of {sup 35}S-labelled ribulose biphosphate carboxylase exposed to UV radiation and immunological experiments using antibodies specific for P65, for the large and small subunits of ribulose biphosphate carboxylase and for high-molecular-mass aggregates of the enzyme. These studies revealed that P65 is a dimer, formed by the covalent, non-disulphide linkage of one small subunit with one large subunit of ribulose biphosphate carboxylase. For short periods of time (<1 h), the amount of P65 formed increased with the duration of the exposure to the UV radiation and with the energy of the radiation applied. Prolonged exposure to UV radiation (1-6 h) resulted in the formation of high-molecular-mass aggregates of ribulose biphosphate carboxylase. Formation of P65 was shown to depend on the native state of the protein, was stimulated by inhibitors of enzyme activity, and was inhibited by activators of enzyme activity. A UV-independent accumulation of P65 was also achieved by the in vitro incubation of plant crude extracts. However, the UV-dependent and the UV-independent formation of P65 seemed to occur by distinct molecular mechanisms. The UV-dependent accumulation of P65 was immunologically detected in all species examined, including Lemna minor, Arum italicum, Brassica oleracea, Triticum aestivum, Zea mays, Pisum sativum and Phaseolus vulgaris, suggesting that it may constitute a universal response to UV radiation, common to all photosynthetic tissues. (Author).

  8. Covalent dimerization of ribulose bisphosphate carboxylase subunits by UV radiation

    International Nuclear Information System (INIS)

    Ferreira, R.M.B.; Universidade Nova de Lisboa, Oeiras; Franco, E.; Teixeira, A.R.N.

    1996-01-01

    The effect of UV radiation (UV-A, UV-B and UV-C) on ribulose bisphosphate carboxylase from a variety of plant species was examined. The exposition of plant leaves or the pure enzyme to UV radiation produced a UV-dependent accumulation of a 65 kDa polypeptide (P65). Different approaches were utilized to elucidate the origin and structure of P65: electrophoretic and fluorographic analyses of 35 S-labelled ribulose biphosphate carboxylase exposed to UV radiation and immunological experiments using antibodies specific for P65, for the large and small subunits of ribulose biphosphate carboxylase and for high-molecular-mass aggregates of the enzyme. These studies revealed that P65 is a dimer, formed by the covalent, non-disulphide linkage of one small subunit with one large subunit of ribulose biphosphate carboxylase. For short periods of time (<1 h), the amount of P65 formed increased with the duration of the exposure to the UV radiation and with the energy of the radiation applied. Prolonged exposure to UV radiation (1-6 h) resulted in the formation of high-molecular-mass aggregates of ribulose biphosphate carboxylase. Formation of P65 was shown to depend on the native state of the protein, was stimulated by inhibitors of enzyme activity, and was inhibited by activators of enzyme activity. A UV-independent accumulation of P65 was also achieved by the in vitro incubation of plant crude extracts. However, the UV-dependent and the UV-independent formation of P65 seemed to occur by distinct molecular mechanisms. The UV-dependent accumulation of P65 was immunologically detected in all species examined, including Lemna minor, Arum italicum, Brassica oleracea, Triticum aestivum, Zea mays, Pisum sativum and Phaseolus vulgaris, suggesting that it may constitute a universal response to UV radiation, common to all photosynthetic tissues. (Author)

  9. Rapid determination of chromium(VI) in electroplating waste water by use of a spectrophotometric flow injection system.

    Science.gov (United States)

    Yuan, Dong; Fu, Dayou; Wang, Rong; Yuan, Jigang

    2008-11-01

    A new rapid and sensitive FI method is reported for spectrophotometric determination of trace chromium(VI) in electroplating waste water. The method is based on the reaction of Cr(VI) with sodium diphenylamine sulfonate (DPH) in acidic medium to form a purple complex (lambda(max) = 550 nm). Under the optimized conditions, the calibration curve is linear in the range 0.04-3.8 microg ml(-1) at a sampling rate of 30 h(-1). The detection limit of the method is 0.0217 microg ml(-1), and the relative standard deviation is 1.1% for eight determinations of 2 microg ml(-1) Cr(VI). The proposed method was applied to the determination of chromium in electroplating waste water with satisfactory results.

  10. Cloud point extraction, preconcentration and spectrophotometric determination of nickel in water samples using dimethylglyoxime

    Directory of Open Access Journals (Sweden)

    Morteza Bahram

    2013-01-01

    Full Text Available A new and simple method for the preconcentration and spectrophotometric determination of trace amounts of nickel was developed by cloud point extraction (CPE. In the proposed work, dimethylglyoxime (DMG was used as the chelating agent and Triton X-114 was selected as a non-ionic surfactant for CPE. The parameters affecting the cloud point extraction including the pH of sample solution, concentration of the chelating agent and surfactant, equilibration temperature and time were optimized. Under the optimum conditions, the calibration graph was linear in the range of 10-150 ng mL-1 with a detection limit of 4 ng mL-1. The relative standard deviation for 9 replicates of 100 ng mL-1 Ni(II was 1.04%. The interference effect of some anions and cations was studied. The method was applied to the determination of Ni(II in water samples with satisfactory results.

  11. UV-enhanced reactivation of minute-virus-of-mice: stimulation of a late step in the viral life cycle

    International Nuclear Information System (INIS)

    Rommelaere, J.; Vos, J.-M.; Cornelis, J.J.

    1981-01-01

    UV-enhanced reactivation of minute-virus-of-mice (MVM), an autonomous parvovirus, was studied in parasynchronous mouse A9 cells. The survival of UV-irradiated MVM is increased in cells which have been UV-irradiated prior to infection. UV-enhanced reactivation can be explained neither by facilitated plaque detection on UV-treated indicator cells, nor by altered kinetics of virus production by UV-irradiated cells. No effect of the multiplicity of infection on virus survival was detected in unirradiated or irradiated cells. The magnitude of UV-enhanced reactivation is a direct exponential function of the UV dose administered to the virus while virus survival is inversely proportional to the UV dosage. The expression of UV-enhanced reactivation can be activated in cells arrested in G 0 , it requires de novo protein synthesis and it is maximal when cells are irradiated 30 h before the onset of viral DNA replication. Early phases of the viral cycle, such as adsorption to cellular receptors, migration to the nucleus and uncoating were not affected by cell irradiation and are unlikely targets of the UV-enhanced reactivation function(s). These results, together with the single-strandedness of the viral genome, strongly suggest that the step stimulated in UV-irradiated cells functions concomitant with, or subsequent to, viral DNA replication. (author)

  12. Laser-based optical activity detection of amino acids and proteins

    Energy Technology Data Exchange (ETDEWEB)

    Reitsma, B.H.

    1987-08-01

    The optical activity detector (OAD) for HPLC is a selective detector for optically active substances including amino acids and proteins. Four free amino acids were resolved using cation-exchange chromatography followed by detection with refractive index detector (RI) for proline and threonine and the OAD to an ultraviolet absorbance detector (uv) for tyrosine and phenylalanine. Amino acid detection by refractive index is not sensitive and uv absorbance detects only three amino acids. Derivatization of amino acids to make them detectable by uv absorbance enhances the applicability of OA/uv for the determination of enantiomeric ratios. The separation of 16 dansyl-L-amino acids by RP-HPLC with detection by OA/uv is illustrated. Calculation of the specific rotation of 22 dansyl-L-amino acids shows that derivatization enhances the OA detectability of some amino acids but degrades that of others. RP-HPLC of proteins is a rapidly developing technique. Several researchers have reported the detection of multiple peaks when a pure protein is subjected to HPLC under certain conditions. These multiple peaks have been determined to be different conformations of the same protein. Since proteins are optically active, OA is a suitable detector. The RP-HPLC separation of conformers of soybean trypsin inhibitor is illustrated. Detection by OA/uv provides insights from the chromatogram unavailable from uv absorbance detection alone. In addition, identification of impurities is simplified with OA/uv. Specific rotations of the separated protein fractions show no significant change accompanying change in conformation. 163 refs., 13 figs., 9 tabs.

  13. Spectrophotometric Determination of Metoprolol Tartrate in Pharmaceutical Dosage Forms on Complex Formation with Cu(II

    Directory of Open Access Journals (Sweden)

    Mustafa Cesme

    2011-06-01

    Full Text Available A new, simple, sensitive and accurate spectrophotometric method has been developed for the assay of metoprolol tartrate (MPT, which is based on the complexation of drug with copper(II [Cu(II] at pH 6.0, using Britton-Robinson buffer solution, to produce a blue adduct. The latter has a maximum absorbance at 675 nm and obeys Beer’s law within the concentration range 8.5-70 mg/mL. Regression analysis of the calibration data showed a good correlation coefficient (r = 0.998 with a limit of detection of 5.56 mg/mL. The proposed procedure has been successfully applied to the determination of this drug in its tablets. In addition, the spectral data and stability constant for the binuclear copper(II complex of MPT (Cu2MPT2Cl2 have been reported.

  14. Spectrophotometric determination of zirconium with Chrome Azurol s in aqueous streams of nuclear fuel reprocessing

    International Nuclear Information System (INIS)

    Ganesh, S.; Velavendan, P.; Pandey, N.K.; Kamachi Mudali, U.; Natarajan, R.

    2014-01-01

    A sensitive and reproducible spectrophotometric method for the determination of zirconium is developed. The method is based on the formation of stable bluish violet colour complex with Chrome Azurol S (CAS) with maximum absorption at 598 nm. The complex formed obeys Beer's law in the range of 1-7 μg/mL. Under optimum conditions, the sensitivity of the proposed method, (i.e. the detection limit), molar absorptivity and Sandell's sensitivity values are 2.42 μg/mL, 3.93 x10 3 L.Mol -1 .cm -1 and 2.54 x 10 -4 μg/cm 2 respectively. Relative standard deviation is less than 2% and correlation coefficient is 0.997. The present method is highly sensitive, selective, rapid and simple. It can be applied for the direct determination of zirconium in environmental, industrial, water and nuclear reprocessing samples. (author)

  15. Validation of quantitative analysis method for triamcinolone in ternary complexes by UV-Vis spectrophotometry

    Directory of Open Access Journals (Sweden)

    GEORGE DARLOS A. AQUINO

    2011-06-01

    Full Text Available Triamcinolone (TRI, a drug widely used in the treatment of ocular inflammatory diseases, is practically insoluble in water, which limits its use in eye drops. Cyclodextrins (CDs have been used to increase the solubility or dissolution rate of drugs. The purpose of the present study was to validate a UV-Vis spectrophotometric method for quantitative analysis of TRI in inclusion complexes with beta-cyclodextrin (B-CD associated with triethanolamine (TEA (ternary complex. The proposed analytical method was validated with respect to the parameters established by the Brazilian regulatory National Agency of Sanitary Monitoring (ANVISA. The analytical measurements of absorbance were made at 242nm, at room temperature, in a 1-cm path-length cuvette. The precision and accuracy studies were performed at five concentration levels (4, 8, 12, 18 and 20μg.mL-1. The B-CD associated with TEA did not provoke any alteration in the photochemical behavior of TRI. The results for the measured analytical parameters showed the success of the method. The standard curve was linear (r2 > 0.999 in the concentration range from 2 to 24 μg.mL-1. The method achieved good precision levels in the inter-day (relative standard deviation-RSD <3.4% and reproducibility (RSD <3.8% tests. The accuracy was about 80% and the pH changes introduced in the robustness study did not reveal any relevant interference at any of the studied concentrations. The experimental results demonstrate a simple, rapid and affordable UV-Vis spectrophotometric method that could be applied to the quantitation of TRI in this ternary complex. Keywords: Validation. Triamcinolone. Beta-cyclodextrin. UV- Vis spectrophotometry. Ternary complexes. RESUMO Validação de método de análise quantitativa para a triancinolona a partir de complexo ternário por espectrofotometria de UV-Vis A triancinolona (TRI é um fármaco amplamente utilizado no tratamento de doenças inflamatórias do globo ocular e

  16. Determination of Efavirenz in Human Dried Blood Spots by Reversed-Phase High Performance Liquid Chromatography with UV Detection

    Science.gov (United States)

    Hoffman, Justin T; Rossi, Steven S; Espina-Quinto, Rowena; Letendre, Scott; Capparelli, Edmund V

    2013-01-01

    Background Previously published methods for determination of efavirenz (EFV) in human dried blood spots (DBS) employ costly and complex liquid chromatography/mass spectrometry. We describe the validation and evaluation of a simple and inexpensive high-performance liquid chromatography (HPLC) method for EFV quantification in human DBS and dried plasma spots (DPS), using ultraviolet (UV) detection appropriate for resource-limited settings. Methods 100μl of heparinized whole blood or plasma were spotted onto blood collection cards, dried, punched, and eluted. Eluates are injected onto a C-18 reversed phase HPLC column. EFV is separated isocratically using a potassium phosphate and ACN mobile phase. UV detection is at 245nm. Quantitation is by use of external calibration standards. Following validation, the method was evaluated using whole blood and plasma from HIV-positive patients undergoing EFV therapy. Results Mean recovery of drug from dried blood spots is 91.5%. The method is linear over the validated concentration range of 0.3125 – 20.0μg/mL. A good correlation (Spearman r=0.96) between paired plasma and DBS EFV concentrations from the clinical samples was observed, and hematocrit level was not found to be a significant determinant of the EFV DBS level. The mean observed CDBS/Cplasma ratio was 0.68. A good correlation (Spearman r=0.96) between paired plasma and DPS EFV concentrations from the clinical samples was observed. The mean percent deviation of DPS samples from plasma samples is 1.68%. Conclusions Dried whole blood spot or dried plasma spot sampling is well suited for monitoring EFV therapy in resource limited settings, particularly when high sensitivity is not essential. PMID:23503446

  17. Spectrophotometric-isotope dilution determination of arsenic in soils and rock

    Science.gov (United States)

    Brown, F.W.; Simon, F.O.; Greenland, L.P.

    1975-01-01

    Arsenic in soil and rock samples may be determined in part-per-million concentrations using a radiochemical-isotope dilution method. Arsenic in the sample plus added As76 tracer is separated as arsine and determined spectrophotometrically as a molybdenum blue complex. The As76 activity in the absorbing solution allows corrections for chemical losses. A lower limit of 1 ppm is determinate in a 0.5-g sample.

  18. Spectrophotometric determination of plutonium with chlorophosphonazo III in n-pentanol

    International Nuclear Information System (INIS)

    Saponara, N.M.; Marsh, S.F.

    1982-03-01

    Microgram amounts of plutonium are measured spectrophotometrically as the plutonium-chlorophosphonazo III complex after extraction into n-pentanol from 1.5 M HCl. The relative standard deviation is 1.5% for the range of 2.5 to 17.5 μg. The tolerance is excellent for many metals and nonmetals present in nuclear fuel-cycle materials. A preceding anion-exchange-column separation increases tolerance for certain metals and nonmetals

  19. Physiological bases for detecting and predicting photoinhibition of aquatic photosynthesis by PAR and UV radiation

    International Nuclear Information System (INIS)

    Neale, P.J.; Cullen, J.J.; Lesser, M.P.; Melis, A.

    1993-01-01

    stress is usually time dependent (12, 36); the light history of the cells must be known to specify the overall effect. The established method for measuring phytoplankton production, photosynthetic incorporation of 14 C into organic carbon during a12-24 h bottle incubation, may seriously misrepresent irradiance regimes actually experienced by phytoplankton in situ. Further discussion of the interaction of photoinhibition and mixing can be found in (36).We propose that an integrated modeling-sampling approach is needed to define the effects of irradiance stress on productivity in situ. The model should incorporate an optical specification of the underwater irradiance environment, abiological weighting function to account for the wavelength-dependence of photoinhibition of photosynthesis, and a response function of biological action during vertical mixing to account for the differences between static incubations and natural movements of phytoplankton. Recently, excellent progress has been made toward defining the individual components of this model (See also Cullen and Neale, this volume). To verify the model, we need to detect reliably the occurrence of irradiance stress in situ. This is the sampling side of the integrated approach. In particular, we would like to differentiate between the effects of PAR and UV. We propose that such detection can be accomplished by indicator assays (or ''diagnostic markers''). Such assays would involve little or no incubation of samples, so that the measurement corresponds as closely as possible to the physiological state of the phytoplankton at time of sampling.Our objective here is to review selected aspects of irradiance stress at biophysical and molecular levels, and then proceed to examine how that information can be used to design indicator assays of irradiance stress for phytoplankton photosynthesis in situ. The effects of PAR and UV at the cellular level and the use of in vivo fluorescence and molecular probes

  20. Spectrophotometric methods for determining noble metals

    International Nuclear Information System (INIS)

    Gur'eva, R.F.; Savvin, S.B.

    2002-01-01

    The main trends of the development of spectrophotometric methods for determining noble metals (NMs) including ruthenium are considered. One of these trends is the synthesis and study of new, highly sensitive and selective organic reagents for determining NMs in solutions and solid phase. Another trend is the search for and developing of new methodological approaches (techniques) and color reactions, including those that involve modified and immobilized reagents. The third trend includes the improvement of equipment and automation. It is shown that the present-day spectrophotometry can provide the determination of NMs in samples with concentrations from several to 10 -4 % (photometry and differential photometry) and down to 10 -7 % (test and sorption-spectroscopic methods based on photometry and diffuse-reflectance spectroscopy, including the use of chromaticity functions) [ru

  1. A rapid and reliable determination of doxycycline hyclate by HPLC with UV detection in pharmaceutical samples

    Directory of Open Access Journals (Sweden)

    SNEZANA S. MITIC

    2008-06-01

    Full Text Available An accurate, sensitive and reproducible high performance liquid chromatographic (HPLC method for the quantification of doxycycline hyclate in pharmaceutical samples has been developed and validated. The drug and the standard were eluted from a Lichrosorb RP-8 (250 mm´4.6 mm, 10 mm particle size at 20 °C with a mobile phase consisting of methanol, acetonitrile and 0.010 M aqueous solution of oxalic acid (2:3:5, v/v/v. The flow rate was 1.25 ml min-1. A UV detector set at 350 nm was used to monitor the effluent. Each analysis required no longer than 4 min. The limits of detection and quantification were 1.15 and 3.84 μg ml-1, respectively. Recoveries for different concentrations ranged from 99.58 to 101.93 %.

  2. Flame Spectrophotometric Determination of Strontium in Water and Biological Material

    Energy Technology Data Exchange (ETDEWEB)

    Joensson, G

    1964-10-15

    A flame spectrophotometric method has been developed for the determination of strontium in biological material and water samples. Strontium is determined in the presence of calcium at a wavelength of 4607 A. The intensity of the strontium emission from the sample is increased if n-butanol is added to a solution of the sample in water. With a 6 vol% solution of n-butanol in water, an optimum intensity of 3.5 times that obtained with pure water solution is obtained. Anions and alkali metals which might interfere with the flame spectrophotometric determination are separated from the sample by a simple ion exchange operation. The method allows determination of strontium in solutions down to 0.1{mu}g/ml. In this case the standard deviation is 3.1 % and with a strontium concentration of 1 {mu}g/ml the deviation is 0.9 %. This method has been used for the determination of strontium in samples of varying composition such as bone, meat and skin from fishes, samples of human bones, shell-fish, milk, and water, in which case Sr quantities of 5{mu}g were determined with an analytical error of less than 5 % and Sr{sub q}uantities greater than 10 {mu}g with an error of less than 3 %.

  3. Flame Spectrophotometric Determination of Strontium in Water and Biological Material

    International Nuclear Information System (INIS)

    Joensson, G.

    1964-10-01

    A flame spectrophotometric method has been developed for the determination of strontium in biological material and water samples. Strontium is determined in the presence of calcium at a wavelength of 4607 A. The intensity of the strontium emission from the sample is increased if n-butanol is added to a solution of the sample in water. With a 6 vol% solution of n-butanol in water, an optimum intensity of 3.5 times that obtained with pure water solution is obtained. Anions and alkali metals which might interfere with the flame spectrophotometric determination are separated from the sample by a simple ion exchange operation. The method allows determination of strontium in solutions down to 0.1μg/ml. In this case the standard deviation is 3.1 % and with a strontium concentration of 1 μg/ml the deviation is 0.9 %. This method has been used for the determination of strontium in samples of varying composition such as bone, meat and skin from fishes, samples of human bones, shell-fish, milk, and water, in which case Sr quantities of 5μg were determined with an analytical error of less than 5 % and Sr q uantities greater than 10 μg with an error of less than 3 %

  4. Polarographic, spectrophotometric and coulometric studies of MoO=4 in H2SO4

    International Nuclear Information System (INIS)

    Tokoro, R.; Bertotti, M.

    1990-01-01

    This study characterizes the polarographic process of Mo O sup(=) sub(4) in H sub(2)SO sub(4) medium, determining which species is responsible by catalytic cycle. Spectrophotometric and coulometric studies are also described. (author)

  5. Solar ultraviolet light potentiates stannous chloride effects as a DNA damaging agent: a spectrophotometrical study

    International Nuclear Information System (INIS)

    Mattos, J.C.P. de; Bernardo-Filho, M.; Leitao, A.C.; Caldeira-de-Araujo, A.; Lage, C.; Leitao, A.C.

    1997-01-01

    Full text. Stannous chloride (Sn Cl 2 ) is a reducing agent widely used to reduce 99m Tc in several radio pharmaceuticals compounds. In spite of being used in nuclear medicine, its genotoxic effects are under investigation in our laboratory. In E. coli, Sn Cl 2 has been shown to have lethal and mutagenic effects, which are thought to occur mainly via active oxygen species. In order to detect some possible direct influence of Sn Cl 2 on nucleic acid, DNA, nucleotides and isolated bases were allowed to react with S N Cl 2 in an in vitro system and the effects analyzed spectro photometrically. Since Sn Cl 2 absorbs light in the UV region, we expected that UV could modify the Sn Cl 2 effects on DNA. Our results indicate that: a. Sn Cl 2 or UV (312 nm, 10 5 J/m 2 ) alone caused only slight alterations in the 260-nm absorption peak of supercoiled plasmid DNA (p U C 9.1); b. Sn Cl 2 + UV (312 nm, 10 5 J/m 2 ) led DNA (p U C 9.1) to a complete loss of its characteristic absorption in the 260-nm region; and c. when reacting with isolated A T P or T T P, Sn Cl 2 + UV (312 nm, 5 x 10 4 J/m 2 ) caused a significant decrease in their 260-nm absorption peaks, as compared to Sn CL 2 alone. Put together, our results indicate that Sn Cl 2 effects are potentiated by the action of solar UV light

  6. Spectrophotometric observations of symbiotic stars

    International Nuclear Information System (INIS)

    Ipatov, A.P.; Yudin, B.F.

    1985-01-01

    The data of spectrophotometric observations of symbiotic stars Z And, AX Per, CI Cyg, BF Cyg, YY Her, V 443 Her, AG Dra, AG Peg, AS 296, EG And, V 1016 Cyg, and HM Sge are presented. The spectral range of observations is 3300-7500 A, resolution is 50 A. The data obtained allowed to reveal specific characteristics inherent to the radiation of symbiotic stars and to estimate the parameters of their individual components. Analysis of the spectra of symbiotic stars in the range of 1300-7500 A wavelengths suggests a hypothesis, according to which a hot source in the Rayleigh - Jeans spectral range has a less steep inclination in the energy distribution, than a black-body one. A disk, formed during cold star substance accretion through an internal Lagrangian point onto a denser component of the system, can play the role of the source. In this case one manages to obtain the energy distribution in the symbiotic star spectrum consistent with the observed distribution

  7. SPECTROPHOTOMETRIC ASSESSMENT OF FERRIC REDUCING POWER OF THE INSTANT COFFEE

    OpenAIRE

    Tsiupko, T. G.; Tishchenko, E. A.; Voronova, O. B.

    2016-01-01

    The methods of antioxidant activity determination of foodstuffs using different indicator systems were discussed. The investigation of ferric reducing power (FRP) of coffee and its individual phenolic components such as chlorogenic (CGA), caffeic (СА), ferulic (FA), gallic (GA), vanillic (VA), protocatechuic (PCA) and uric (UA) acids as well as quercetin (Qu) and catechol (C) using the spectrophotometric method with Fe(III) - o-Phen indicator system was carried out. It was shown that the sens...

  8. Comparative study of the formation of brominated disinfection byproducts in UV/persulfate and UV/H2O2 oxidation processes in the presence of bromide.

    Science.gov (United States)

    Wang, Lu; Ji, Yuefei; Lu, Junhe; Kong, Deyang; Yin, Xiaoming; Zhou, Quansuo

    2017-10-01

    The objective of this research was to compare the transformation of Br - and formation of brominated byproducts in UV/persulfate (PS) and UV/H 2 O 2 processes. It was revealed that Br - was efficiently transformed to free bromine which reacted with humic acid (HA) or dihydroxybenzoic acid resulting in the formation of brominated byproducts such as bromoacetic acids (BAAs) in UV/PS system. In contrast, no free bromine and brominated byproducts could be detected in UV/H 2 O 2 system, although the oxidization of Br - was evident. We presumed that the oxidation of Br - by hydroxyl radicals led to the formation of bromine radicals. However, the bromine radical species could be immediately reduced back to Br - by H 2 O 2 before coupling to each other to form free bromine, which explains the undetection of free bromine and BAAs in UV/H 2 O 2 . In addition to free bromine, we found that the phenolic functionalities in HA molecules, which served as the principal reactive sites for free chlorine attack, could be in situ generated when HA was exposed to free radicals. This study demonstrates that UV/H 2 O 2 is more suitable than UV/PS for the treatment of environmental matrices containing Br - . Graphical abstract Graphical abstract.

  9. Evaluation of Combined Peracetic acid and UV treatment for ...

    Science.gov (United States)

    The current study evaluates the effectiveness of the combined application of Peracetic acid and ultraviolet radiation as alternative disinfectant agents to the traditional chlorination of wastewater effluents. Various pathogens (E. coli, enterococci and fecal coliforms) were evaluated in the study. Four experiments were conducted using low to high PAA levels and UV dosages. E. coli and enterococci were resistant to low to moderate PAA dosage (0.5- 1 mg/L). These microbes can be removed effectively at high PAA dosage (2.5 mg/L) with 30 min contact time. Fecal coliforms were completely inactivated even at a low PAA dose of 0.7 mg/L. E. coli was more susceptible to UV disinfection than enterococci at low UV dosages. Enterococci required at least 40 mJ/cm2 for 2.5 log inactivation. In combined PAA + UV treatment, low UV intensities between 7 – 40 mJ/cm2 showed poor disinfection performance at a low PAA concentration of 1.5 mg/L. High UV intensities of 120 and 60 mJ/cm2 inactivated all the pathogens to below detection levels even at low to moderate PAA (0.7 mg/L and 1 mg/L) pretreatment concentration. Combined PAA + UV treatment at 1 mg/L (for 15 and 30 min contact time) + 120 and 60 mJ/cm2 did not show any regrowth of microbes, whereas PAA only disinfection with 15 min contact time showed regrowth of enterococci and fecal coliforms. UV only disinfection showed E. coli regrowth. • This pilot scale study was designed for providing necessary parameter optimization

  10. Analysis of Protein by Spectrophotometric and Computer Colour Based Intensity Method from Stem of Pea (Pisum sativum at Different Stages

    Directory of Open Access Journals (Sweden)

    Afsheen Mushtaque Shah

    2010-12-01

    Full Text Available In this study proteins were analyzed from pea plants at three different growth stages of stem by spectrophotometric i.e Lowry and Bradford quantitative methods and computer colour intensity based method. Though Spectrophotometric methods are regarded as classical methods, we report an alternate computer based method which gave comparable results. Computer software was developed the for protein analysis which is easier, time and money saving method as compared to the classical methods.

  11. Assessment of interplay between UV wavelengths, material surfaces and food residues in open surface hygiene validation

    DEFF Research Database (Denmark)

    Abban, Stephen; Jakobsen, Mogens; Jespersen, Lene

    2014-01-01

    The use of UV-visible radiation for detecting invisible residue on different surfaces as a means of validating cleanliness was investigated. Wavelengths at 365, 395, 435, 445, 470 and 490 nm from a monochromator were used to detect residues of beef, chicken, apple, mango and skim milk. These were....... It is important when UV-systems are used as real-time tools for assessing cleanliness of surfaces that the surface materials being illuminated are taken into account in the choice of lamp wavelength, in addition to expected residue. This will ensure higher confidence in results during the use of UV-light for real...

  12. Spectrophotometric study of holmium complexation in KOH solutions at 25 Deg C

    International Nuclear Information System (INIS)

    Stepanchikova, S.A.; Bitejkina, R.P.

    2006-01-01

    Complexation of Ho 3+ in solutions of HoCl 3 and KOH at 25 Deg C is studied by indicator spectrophotometric method. Within the range of pH 9.25-10.10 and μ≤4 x 10 -4 stability constants of Ho 3+ hydroxocomplexes are measured and are extrapolated on zero ion strength [ru

  13. Determination of cyanide by an indirect spectrophotometric method using 5-Br-PADAP.

    Science.gov (United States)

    Fu-Sheng, W; Yu-Qin, L; Fang, Y; Nai-Kui, S

    1981-09-01

    Complexation of Ni(2+) with cyanide inhibits its colour reaction with 5-Br-PADAP and this reaction is used in the spectrophotometric determination of cyanide at the ug level. Cyanide in industrial waste waters is determined after an initial transfer as hydrogen cyanide from the sample into sodium hydroxide solution with a stream of air.

  14. Plant responses to UV-B irradiation are modified by UV-A irradiation

    International Nuclear Information System (INIS)

    Middleton, E.M.; Teramura, A.H.

    1993-01-01

    The increasing UV-B radiation (0.28-0.32 μm) reaching the earth's surface is an important concern. Plant response in artificial UV-B irradiation studies has been difficult to assess, especially regarding photosynthetic pigments, because the fluorescent lamps also produce UV-A (0.32-0.40μm) radiation which is involved with blue light in pigment synthesis. Both UV-A and UV-B irradiances were controlled in two glasshouse experiments conducted under relatively high PPFD (> 1300μmol m -2 s -1 ) at two biologically effective daily UV-B irradiances (10.7 and 14.1 kJ m -2 ); UV-A irradiances were matched in Controls (∼5, 9 kJ m -2 ). Normal, chlorophyll-deficient, and flavonoid-deficient isolines of soybean cultivar, Clark, were utilized. Many growth/ pigment variables exhibited a statistically significant interaction between light quality and quantity: in general, UV-A radiation moderated the damaging effects of UV-B radiation. Regression analyses demonstrated that a single negative function related photosynthetic efficiency to carotenoid Content (r 2 =0.73, P≤0.001), implying a open-quotes costclose quotes in maintaining carotenoids for photoprotection. A stomatal limitation to photosynthesis was verified and carotenoid content was correlated with UV-B absorbing compound levels, in UV-B irradiated plants

  15. Spectrophotometric determination of low levels arsenic species in beverages after ion-pairing vortex-assisted cloud-point extraction with acridine red.

    Science.gov (United States)

    Altunay, Nail; Gürkan, Ramazan; Kır, Ufuk

    2016-01-01

    A new, low-cost, micellar-sensitive and selective spectrophotometric method was developed for the determination of inorganic arsenic (As) species in beverage samples. Vortex-assisted cloud-point extraction (VA-CPE) was used for the efficient pre-concentration of As(V) in the selected samples. The method is based on selective and sensitive ion-pairing of As(V) with acridine red (ARH(+)) in the presence of pyrogallol and sequential extraction into the micellar phase of Triton X-45 at pH 6.0. Under the optimised conditions, the calibration curve was highly linear in the range of 0.8-280 µg l(-1) for As(V). The limits of detection and quantification of the method were 0.25 and 0.83 µg l(-1), respectively. The method was successfully applied to the determination of trace As in the pre-treated and digested samples under microwave and ultrasonic power. As(V) and total As levels in the samples were spectrophotometrically determined after pre-concentration with VA-CPE at 494 nm before and after oxidation with acidic KMnO4. The As(III) levels were calculated from the difference between As(V) and total As levels. The accuracy of the method was demonstrated by analysis of two certified reference materials (CRMs) where the measured values for As were statistically within the 95% confidence limit for the certified values.

  16. TITRIMETRIC AND SENSITIVE SPECTRO-PHOTOMETRIC METHODS FOR THE ASSAY OF QUETIAPINE FUMARATE IN PHARMACEUTICAL FORMULATIONS

    Directory of Open Access Journals (Sweden)

    Nagaraju Rajendraprasad

    2011-03-01

    Full Text Available Quetiapine fumarate (QTF is a selective monoaminergic antagonist with high affinity for the serotonin Type 2 (5HT2, and dopamine type 2 (D2 receptors. Titrimetric and spectrophotometric assay of quetiapine fumarate (QTF using perchloric acid and acetic acid as reagents are described. The first method (method A is a non-aqueous titrimetric method and is based on the titration of QTF in glacial acetic acid with 0.01 M acetous perchloric acid using crystal violet as indicator. In the second method (method B, QTF has been measured in 0.1M acetic acid spectrophotometrically at a wavelength of 222 nm. The titri¬metric method was applicable over the range of 2.0–20.0 mg of QTF. The reac¬tion stoichiometry of 1:3 is obtained which served as the basis for calculation. In spectrophotometry, Beer’s law was obeyed over the concentration range of 1.25–15.0 µg mL-1. The linear regression equation of the calibration graph was A = 0.0115 + 0.0673c with a regression coefficient (r of 0.9986 (n = 7. The apparent molar absorptivity was calculated to be 4.25104 L mol-1cm-1 and the Sandell sensitivity was 0.0145 µg cm-2. The limits of detection (LOD and quantification (LOQ calculated as per the ICH guidelines were 0.07 and 0.21 µg mL-1, respectively. Accuracy and precision of the assays were determined by computing the intra-day and inter-day variations at three different levels of QTF. The intra-day and inter-day relative standard deviation (%RSD were in the range of 0.99–2.88 and 1.65–2.32%, for method A and B, respectively, with an acceptable percentage relative error (%RE < 2%. The methods were successfully applied to the determination of QTF in two different brands of tablets with good accuracy and precision and without detectable interference by excipients. The methods have demonstrated to be simple and easy to apply in routine usage and do not need any costly instrumentation. Therefore, the proposed procedures are advantageous and can be

  17. Are UV photolysis and UV/H2O2 process efficient to treat estrogens in waters? Chemical and biological assessment at pilot scale.

    Science.gov (United States)

    Cédat, Bruno; de Brauer, Christine; Métivier, Hélène; Dumont, Nathalie; Tutundjan, Renaud

    2016-09-01

    In this study, UV based treatments were implemented at pilot scale to assess their ability to remove hormones from treated wastewater, especially with the view to equip small and medium size Wastewater Treatment Plants (WTPs). To this end, the degradation of a mixture of estrogenic hormones (Estrone (E1), β-Estradiol (E2), and 17α-Ethinyl Estradiol (EE2)) in waters by UV photolysis and UV/H2O2 process was investigated in real conditions. A particular attention was paid at designing a well validated laboratory scale pilot in order to optimise oxidant concentrations and UV fluence. A Low pressure lamp (254 nm) was used in a flow through commercial reactor. The effects of water matrices (drinking water and treated wastewater) and H2O2 concentrations (10, 40, and 90 mg/L) on the pilot efficiency were first determined. Only E1 could be partially degraded by UV photolysis whereas hormones were all well removed by UV/H2O2 process in both matrices. The second part of the study focused on a chemical and biological assessment of UV photolysis and UV/H2O2 process (30 and 50 mg/L). Degradation rate constants of hormones as well as changes in estrogenic activity (YES bioassay) and toxicity (Vibrio fischeri) were followed at the same time. UV photolysis could not remove neither estrogens nor estrogenic activity at relevant UV fluence in waters. However 80% of initial estrogenic compounds and estrogenic activity could be removed from treated wastewater by combining UV fluence of 423 and 520 mJ/cm(2) with 50 and 30 mg/L of H2O2, respectively. No high estrogenic or toxic by-products were detected by the two bioassays following UV photolysis or UV/H2O2 process. Operating costs were estimated for a full scale pilot. H2O2 was the major cost. By combining the appropriate concentration of H2O2 and UV fluence, it could be possible to design a cost effective treatment for treating estrogens in small and medium size WTPs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Microbial UV fluence-response assessment using a novel UV-LED collimated beam system.

    Science.gov (United States)

    Bowker, Colleen; Sain, Amanda; Shatalov, Max; Ducoste, Joel

    2011-02-01

    A research study has been performed to determine the ultraviolet (UV) fluence-response of several target non-pathogenic microorganisms to UV light emitting diodes (UV-LEDs) by performing collimated beam tests. UV-LEDs do not contain toxic mercury, offer design flexibility due to their small size, and have a longer operational life than mercury lamps. Comsol Multiphysics was utilized to create an optimal UV-LED collimated beam design based on number and spacing of UV-LEDs and distance of the sample from the light source while minimizing the overall cost. The optimized UV-LED collimated beam apparatus and a low-pressure mercury lamp collimated beam apparatus were used to determine the UV fluence-response of three surrogate microorganisms (Escherichia coli, MS-2, T7) to 255 nm UV-LEDs, 275 nm UV-LEDs, and 254 nm low-pressure mercury lamps. Irradiation by low-pressure mercury lamps produced greater E. coli and MS-2 inactivation than 255 nm and 275 nm UV-LEDs and similar T7 inactivation to irradiation by 275 nm UV-LEDs. The 275 nm UV-LEDs produced more efficient T7 and E. coli inactivation than 255 nm UV-LEDs while both 255 nm and 275 nm UV-LEDs produced comparable microbial inactivation for MS-2. Differences may have been caused by a departure from the time-dose reciprocity law due to microbial repair mechanisms. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. A Facile, Nonreactive Hydrogen Peroxide (H2O2) Detection Method Enabled by Ion Chromatography with UV Detector.

    Science.gov (United States)

    Song, Mingrui; Wang, Junli; Chen, Baiyang; Wang, Lei

    2017-11-07

    Hydrogen peroxide (H 2 O 2 ) is ubiquitous in the natural environment, and it is now widely used for pollutant control in water and wastewater treatment processes. However, current analytical methods for H 2 O 2 inevitably require reactions between H 2 O 2 and other reactants to yield signals and are thus likely subjective to the interferences of coexisting colored, oxidative, and reductive compounds. In order to overcome these barriers, we herein for the first time propose to analyze H 2 O 2 by ion chromatography (IC) using an ultraviolet (UV) detector. The proposal is based on two principles: first, that H 2 O 2 can deprotonate to hydroperoxyl ion (HO 2 - ) when eluent pH is higher than the acid-dissociation coefficient of H 2 O 2 (pK a = 11.6); and second, that after separation from other compounds via IC column, H 2 O 2 can be quantified by a UV detector. Under favorable operating conditions, this method has successfully achieved acceptable recoveries (>91%) of H 2 O 2 dosed to ultrapure and natural waters, a calibration curve with R 2 > 0.99 for a wide range of H 2 O 2 concentrations from 0.1 to 50 mg/L and a method detection limit of 0.027 mg/L. In addition, this approach was shown to be capable of distinguishing H 2 O 2 from anions (e.g., fluoride and chloride) and organics (e.g., glycolate) and monochloramine, suggesting that it is insensitive to many neighboring compounds as long as they do not react quickly with H 2 O 2 . Hence, this study proves the combination of IC and UV detector a facile and reliable method for H 2 O 2 measurement.

  20. Biobased Nanoparticles for Broadband UV Protection with Photostabilized UV Filters

    NARCIS (Netherlands)

    Hayden, D.R.|info:eu-repo/dai/nl/412640694; Imhof, A.|info:eu-repo/dai/nl/145641600; Velikov, K. P.|info:eu-repo/dai/nl/239483472

    2016-01-01

    Sunscreens rely on multiple compounds to provide effective and safe protection against UV radiation. UV filters in sunscreens, in particular, provide broadband UV protection but are heavily linked to adverse health effects due to the generation of carcinogenic skin-damaging reactive oxygen species

  1. Highly Selective and Sensitized Spectrophotometric Determination of Iron (3) Following Potentiometric Study

    International Nuclear Information System (INIS)

    Shokrollahi, A.; Ghaedi, M.; Rajabi, H.R.

    2007-01-01

    A simple, selective and sensitized spectrophotometric method for determination of trace amounts of Fe 3+ ion in tap and waste water solutions has been described. The spectrophotometric determination of Fe 3+ ion using Ferron in the presence of N,N-Dodecy trimethylammonium bromide (DTAB) has been carried out. The Beer's law is obeyed over the concentration range of 0.05-2.6 μg mL -1 of Fe 3+ ion with the relative standard deviation (RSD %) 3 L mol -1 cm -1 . Potentiometric pH titration has been used for prediction of protonation constants of ferron, and evaluating its stoichiometry and respective stability constant with Fe 3+ ion. As it is obvious the most likely species of ferron alone and its complexes are LH (log=7.64), LH 2 (logK=10.52), LH 3 (logK=11.74) and ML 2 (logβ= 23.68), ML 3 (logβ23.68), ML 3 H (logβ= 23.68), ML 3 H 2 (logβ= 23.68) and ML(OH) 2 (logβ=23.68) respectively

  2. Spectrophotometric determination of chlorthalidone in pharmaceutical formulations using different order derivative methods

    Directory of Open Access Journals (Sweden)

    Narmeen S. Abdullah

    2017-05-01

    Full Text Available Simple, repaid and accurate zero-, first- and second-order derivative spectrophotometric methods have been developed for determination of chlorthalidone (CLT in commercially available tablets. Normal spectrophotometric scan (zero order shows maximum absorbance at 276 nm in methanol solution and a good linearity in the range of 10.0–75.0 μg/mL. Linear relations using first (D1 and second (D2 order derivative methods were obtained at 278 and 288 nm for D1 and 286 and 292 nm for D2.The calibration curves were constructed in the range of 1.0–25.0 μg/mL for D1 (R = 0.998 and D2 (R = 0.999. Different analytical validations were determined (accuracy, precision, specificity, recovery, stability and robustness to demonstrate its suitability for routine quality control labs. All the developed methods were successfully applied to a tablet formulation and the results were compared statistically with each other and with those obtained by the HPLC reference method.

  3. UV-induced transcription from the human immunodeficiency virus type 1 (HIV-1) long terminal repeat and UV-induced secretion of an extracellular factor that induces HIV-1 transcription in nonirradiated cells

    International Nuclear Information System (INIS)

    Stein, B.; Kraemer, M.R.; Rahmsdorf, H.J.; Ponta, H.; Herrlich, P.

    1989-01-01

    UV irradiation, but not visible sunlight, induces the transcription of human immunodeficiency virus type 1 (HIV-1). Chimeric constructs carrying all or parts of the HIV-1 long terminal repeat linked to an indicator gene were transfected into HeLa cells or murine and human T-cell lines, and their response to irradiation was tested. The cis-acting element conferring UV responsiveness is identical to the sequence binding transcription factor NF kappa B. UV irradiation enhances NF kappa B binding activity as assayed by gel retardation experiments. Interestingly, the requirement for UV irradiation can be replaced by cocultivation of transfected cells with UV-irradiated nontransfected (HIV-1-negative) cells. A UV-induced extracellular protein factor is detected in the culture medium conditioned by UV-treated cells. The factor is produced upon UV irradiation by several murine and human cell lines, including HeLa, Molt-4, and Jurkat, and acts on several cells. These data suggest that the UV response of keratinocytes in human skin can be magnified and spread to deeper layers that are more shielded, including the Langerhans cells, and that this indirect UV response may contribute to the activation of HIV-1 in humans

  4. A nanosilver-based spectrophotometric method for determination of malachite green in surface water samples.

    Science.gov (United States)

    Sahraei, R; Farmany, A; Mortazavi, S S; Noorizadeh, H

    2013-07-01

    A new spectrophotometric method is reported for the determination of nanomolar level of malachite green in surface water samples. The method is based on the catalytic effect of silver nanoparticles on the oxidation of malachite green by hexacyanoferrate (III) in acetate-acetic acid medium. The absorbance is measured at 610 nm with the fixed-time method. Under the optimum conditions, the linear range was 8.0 × 10(-9)-2.0 × 10(-7) mol L(-1) malachite green with a correlation coefficient of 0.996. The limit of detection (S/N = 3) was 2.0 × 10(-9) mol L(-1). Relative standard deviation for ten replicate determinations of 1.0 × 10(-8) mol L(-1) malachite green was 1.86%. The method is featured with good accuracy and reproducibility for malachite green determination in surface water samples without any pre-concentration and separation step.

  5. Soft, stretchable, epidermal sensor with integrated electronics and photochemistry for measuring personal UV exposures.

    Science.gov (United States)

    Shi, Yunzhou; Manco, Megan; Moyal, Dominique; Huppert, Gil; Araki, Hitoshi; Banks, Anthony; Joshi, Hemant; McKenzie, Richard; Seewald, Alex; Griffin, Guy; Sen-Gupta, Ellora; Wright, Donald; Bastien, Philippe; Valceschini, Florent; Seité, Sophie; Wright, John A; Ghaffari, Roozbeh; Rogers, John; Balooch, Guive; Pielak, Rafal M

    2018-01-01

    Excessive ultraviolet (UV) radiation induces acute and chronic effects on the skin, eye and immune system. Personalized monitoring of UV radiation is thus paramount to measure the extent of personal sun exposure, which could vary with environment, lifestyle, and sunscreen use. Here, we demonstrate an ultralow modulus, stretchable, skin-mounted UV patch that measures personal UV doses. The patch contains functional layers of ultrathin stretchable electronics and a photosensitive patterned dye that reacts to UV radiation. Color changes in the photosensitive dyes correspond to UV radiation intensity and are analyzed with a smartphone camera. A software application has feature recognition, lighting condition correction, and quantification algorithms that detect and quantify changes in color. These color changes are then correlated with corresponding shifts in UV dose, and compared to existing UV dose risk levels. The soft mechanics of the UV patch allow for multi-day wear in the presence of sunscreen and water. Two evaluation studies serve to demonstrate the utility of the UV patch during daily activities with and without sunscreen application.

  6. Soft, stretchable, epidermal sensor with integrated electronics and photochemistry for measuring personal UV exposures

    Science.gov (United States)

    Shi, Yunzhou; Manco, Megan; Moyal, Dominique; Huppert, Gil; Araki, Hitoshi; Banks, Anthony; Joshi, Hemant; McKenzie, Richard; Seewald, Alex; Griffin, Guy; Sen-Gupta, Ellora; Wright, Donald; Bastien, Philippe; Valceschini, Florent; Seité, Sophie; Wright, John A.; Ghaffari, Roozbeh; Rogers, John; Balooch, Guive

    2018-01-01

    Excessive ultraviolet (UV) radiation induces acute and chronic effects on the skin, eye and immune system. Personalized monitoring of UV radiation is thus paramount to measure the extent of personal sun exposure, which could vary with environment, lifestyle, and sunscreen use. Here, we demonstrate an ultralow modulus, stretchable, skin-mounted UV patch that measures personal UV doses. The patch contains functional layers of ultrathin stretchable electronics and a photosensitive patterned dye that reacts to UV radiation. Color changes in the photosensitive dyes correspond to UV radiation intensity and are analyzed with a smartphone camera. A software application has feature recognition, lighting condition correction, and quantification algorithms that detect and quantify changes in color. These color changes are then correlated with corresponding shifts in UV dose, and compared to existing UV dose risk levels. The soft mechanics of the UV patch allow for multi-day wear in the presence of sunscreen and water. Two evaluation studies serve to demonstrate the utility of the UV patch during daily activities with and without sunscreen application. PMID:29293664

  7. Soft, stretchable, epidermal sensor with integrated electronics and photochemistry for measuring personal UV exposures.

    Directory of Open Access Journals (Sweden)

    Yunzhou Shi

    Full Text Available Excessive ultraviolet (UV radiation induces acute and chronic effects on the skin, eye and immune system. Personalized monitoring of UV radiation is thus paramount to measure the extent of personal sun exposure, which could vary with environment, lifestyle, and sunscreen use. Here, we demonstrate an ultralow modulus, stretchable, skin-mounted UV patch that measures personal UV doses. The patch contains functional layers of ultrathin stretchable electronics and a photosensitive patterned dye that reacts to UV radiation. Color changes in the photosensitive dyes correspond to UV radiation intensity and are analyzed with a smartphone camera. A software application has feature recognition, lighting condition correction, and quantification algorithms that detect and quantify changes in color. These color changes are then correlated with corresponding shifts in UV dose, and compared to existing UV dose risk levels. The soft mechanics of the UV patch allow for multi-day wear in the presence of sunscreen and water. Two evaluation studies serve to demonstrate the utility of the UV patch during daily activities with and without sunscreen application.

  8. Effects of UV-B radiation on the isoflavone accumulation and physiological-biochemical changes of soybean during germination: Physiological-biochemical change of germinated soybean induced by UV-B.

    Science.gov (United States)

    Ma, Meng; Wang, Pei; Yang, Runqiang; Gu, Zhenxin

    2018-06-01

    In this study, the effects of UV-B radiation on the isoflavones accumulation, physiological and nutritional quality, water status, and characteristics of proteins in germinated soybeans were investigated. The results showed that isoflavones content in soybeans increased with appropriate intensity and time of UV-B radiation and decreased with excessive treatment. Fresh weight, length, free amino acids, reducing sugar contents and bulk water (T 23 ) in germinated soybeans decreased with increasing radiation time, indicating that UV-B inhibited the growth and nutrients metabolism of soybean during germination. Cell damage was detected in germinated soybeans with excessive UV-B radiation, as shown by the black spots in cotyledons and the increased intercellular water determined by LF-NMR. Germination resulted in an increase in random coil structures, while UV-B radiation induced no obvious changes in FT-IR spectrum and protein conformation of soybeans. Both UV-B radiation and germination caused the increase in soluble proteins, especially in 1.0-75.0 kDa fraction. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. ZnO UV photodetector with controllable quality factor and photosensitivity

    Directory of Open Access Journals (Sweden)

    L. C. Campos

    2013-02-01

    Full Text Available ZnO nanowires have an enormous potential for applications as ultra-violet (UV photodetectors. Their mechanism of photocurrent generation is intimately related with the presence of surface states where considerable efforts, such as surface chemical modifications, have been pursued to improve their photodetection capabilities. In this work, we report a step further in this direction demonstrating that the relative photosensitivity and quality factor (Q factor of the photodetector are entirely tunable by an applied gate voltage. This mechanism enables UV photodetection selectivity ranging from wavelengths from tens of nanometers (full width at half maximum - FWHM down to a narrow detection of 3 nm. Such control paves the way for novel applications, especially related to the detection of elements that have very sharp luminescence.

  10. Image registration for a UV-Visible dual-band imaging system

    Science.gov (United States)

    Chen, Tao; Yuan, Shuang; Li, Jianping; Xing, Sheng; Zhang, Honglong; Dong, Yuming; Chen, Liangpei; Liu, Peng; Jiao, Guohua

    2018-06-01

    The detection of corona discharge is an effective way for early fault diagnosis of power equipment. UV-Visible dual-band imaging can detect and locate corona discharge spot at all-weather condition. In this study, we introduce an image registration protocol for this dual-band imaging system. The protocol consists of UV image denoising and affine transformation model establishment. We report the algorithm details of UV image preprocessing, affine transformation model establishment and relevant experiments for verification of their feasibility. The denoising algorithm was based on a correlation operation between raw UV images, a continuous mask and the transformation model was established by using corner feature and a statistical method. Finally, an image fusion test was carried out to verify the accuracy of affine transformation model. It has proved the average position displacement error between corona discharge and equipment fault at different distances in a 2.5m-20 m range are 1.34 mm and 1.92 mm in the horizontal and vertical directions, respectively, which are precise enough for most industrial applications. The resultant protocol is not only expected to improve the efficiency and accuracy of such imaging system for locating corona discharge spot, but also supposed to provide a more generalized reference for the calibration of various dual-band imaging systems in practice.

  11. Studies of aluminium nitride ceramics for application in UV dosimetry

    DEFF Research Database (Denmark)

    Trinkler, L.; Bøtter-Jensen, L.; Christensen, P.

    2000-01-01

    The study is reported of the ceramic material AlN-Y2O3 as a potential luminescence dosemeter for the detection of UV radiation. Both the thermoluminescence and the optically stimulated luminescence properties of the material have been studied after exposure to UV radiation and compared with those...... of the widely used dosemeter material Al2O3:C. It has been shown that AlN-Y2O3 ceramics exhibit three orders of magnitude higher sensitivity to UV radiation than does Al2O3,:C over a broad spectral region. The thermoluminescence from AlN-Y2O3 is characterised by linear dose dependence over a wide range....... The fading characteristics of the UV-induced thermoluminescence and optically stimulated luminescence signals with storage time at room temperature were found to be a drawback, but still lower than those induced after exposure to ionising radiation....

  12. Spectrophotometric determination of fluorides in water with Hach equipment

    International Nuclear Information System (INIS)

    Acosta L, E.

    1994-11-01

    The spectrophotometric method for the determination of the fluoride ion in water, demineralized water, raw waters, laundry waters and waters treated with ion exchange resins , using the technique and the SPADNS coloring indicated in the operation manual of the Hach equipment is described. This method covers the determination of the fluoride ion in the range from 0 to 2 mg/l on 25 ml. of radioactive base sample. These limits can be variable if the size of the used aliquot one is changed for the final determination of the fluoride ion. (Author)

  13. Flavonoids are systemically induced by UV-B in Zea mays

    International Nuclear Information System (INIS)

    Tossi, V.E.; Lamattina, L.; Cassia, R.

    2009-01-01

    Flavonoid concentration is increased by UV-B irradiation, but it is unknown if this is a local or systemic response. Nitric oxide (NO) is a diffusible molecule involved in the UV-B response. NO regulates the expression of chalcone synthase (CHS), a key enzyme in the synthesis of flavonoids. The aim of this work was to determine if maize flavonoids are local or systemically induced by UV-B, and what is the participation of NO in this response. We have used maize seedlings where the second leaf was sprayed with H 2 O or cPTIO (a NO scavenger), and then completely covered (C), partially covered (P) or uncovered (U) before to be UV-B irradiated. The results show a 60% increase in the NO concentration of U, 42% in P and 35% in C respectively. Flavonoid concentration increased 90% in C, 70% in P and 40% in U. Flavonoid concentration was reduced when leaves were pretreated with cPTIO before the UV-B irradiation. RT-PCR shows that CHS was up-regulated by UV-B in U, P and C, but downregulated with cPTIO. We have analyzed the subcellular localization of flavonoid and NO in UV-B irradiated plants. Flavonoid localization was coincident with the NO presence in the irradiated surface of the leaves and flavonoids were detected in vesicles. These results indicate that flavonoids are systemically induced by UV-B in a NO-related mechanism. (authors)

  14. Simultaneous determination of the brand new two-drug combination for the treatment of hepatitis C: Sofosbuvir/ledipasvir using smart spectrophotometric methods manipulating ratio spectra

    Science.gov (United States)

    Eissa, Maya S.

    2017-08-01

    In this work, various sensitive and selective spectrophotometric methods were first introduced for the simultaneous determination of sofosbuvir and ledipasvir in their binary mixture without preliminary separation. Ledipasvir was determined simply by zero-order spectrophotometric method at its λmax = 333.0 nm in a linear range of 2.5-30.0 μg/ml without any interference of sofosbuvir even in low or high concentrations and with mean percentage recovery of 100.05 ± 0.632. Sofosbuvir can be quantitatively estimated by one of the following smart spectrophotometric methods based on ratio spectra developed for the resolution of the overlapped spectra of their binary mixture; ratio difference spectrophotometric method (RD) by computing the difference between the amplitudes of sofosbuvir ratio spectra at 228 nm and 270 nm, first derivative (DD1) of ratio spectra by measuring the sum of amplitude of trough and peak at 265 nm and 277 nm, respectively, ratio subtraction (RS) spectrophotometric method in which sofosbuvir can be successfully determined at its λmax = 261.0 nm and mean centering (MC) of ratio spectra by measuring the mean centering values at 270 nm. All of the above mentioned spectrophotometric methods can estimate sofosbuvir in a linear range of 7.5-90.0 μg/ml with mean percentage recoveries of 100.57 ± 0.810, 99.92 ± 0.759, 99.51 ± 0.475 and 100.75 ± 0.672, respectively. These methods were successfully applied to the analysis of their combined dosage form and bulk powder. The adopted methods were also validated as per ICH guidelines and statistically compared to an in-house HPLC method.

  15. UV filters bioaccumulation in fish from Iberian river basins

    Energy Technology Data Exchange (ETDEWEB)

    Gago-Ferrero, Pablo [Dept. of Environmental Chemistry, Institute of Environmental Assessment and Water Research (IDAEA), Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, E-08034 Barcelona (Spain); Laboratory of Analytical Chemistry, Department of Chemistry, National and Kapodistrian University of Athens, Panepistimiopolis, 15771 Athens (Greece); Díaz-Cruz, M. Silvia, E-mail: sdcqam@cid.csic.es [Dept. of Environmental Chemistry, Institute of Environmental Assessment and Water Research (IDAEA), Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, E-08034 Barcelona (Spain); Barceló, Damià [Dept. of Environmental Chemistry, Institute of Environmental Assessment and Water Research (IDAEA), Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, E-08034 Barcelona (Spain); Catalan Institute for Water Research (ICRA), Parc Científic i Tecnològic de la Universitat de Girona, C/ Emili Grahit, 101 Edifici H2O, E-17003 Girona (Spain)

    2015-06-15

    The occurrence of eight organic UV filters (UV-Fs) was assessed in fish from four Iberian river basins. This group of compounds is extensively used in cosmetic products and other industrial goods to avoid the damaging effects of UV radiation, and has been found to be ubiquitous contaminants in the aquatic ecosystem. In particular, fish are considered by the scientific community to be the most feasible organism for contamination monitoring in aquatic ecosystems. Despite that, studies on the bioaccumulation of UV-F are scarce. In this study fish samples from four Iberian river basins under high anthropogenic pressure were analysed by liquid chromatography–tandem mass spectrometry (HPLC–MS/MS). Benzophenone-3 (BP3), ethylhexyl methoxycinnamate (EHMC), 4-methylbenzylidene camphor (4MBC) and octocrylene (OC) were the predominant pollutants in the fish samples, with concentrations in the range of ng/g dry weight (d.w.). The results indicated that most polluted area corresponded to Guadalquivir River basin, where maximum concentrations were found for EHMC (241.7 ng/g d.w.). Sediments from this river basin were also analysed. Lower values were observed in relation to fish for OC and EHMC, ranging from below the limits of detection to 23 ng/g d.w. Accumulation levels of UV-F in the fish were used to calculate biota-sediment accumulation factors (BSAFs). These values were always below 1, in the range of 0.04–0.3, indicating that the target UV-Fs are excreted by fish only to some extent. The fact that the highest concentrations were determined in predators suggests that biomagnification of UV-F may take place along the freshwater food web. - Highlights: • First evidence of UV filters in fish from Iberian rivers • Biota-sediment accumulation factors (BSAFs) were always below 1. • Predator species presented higher UV-F concentrations suggesting trophic magnification.

  16. UV filters bioaccumulation in fish from Iberian river basins

    International Nuclear Information System (INIS)

    Gago-Ferrero, Pablo; Díaz-Cruz, M. Silvia; Barceló, Damià

    2015-01-01

    The occurrence of eight organic UV filters (UV-Fs) was assessed in fish from four Iberian river basins. This group of compounds is extensively used in cosmetic products and other industrial goods to avoid the damaging effects of UV radiation, and has been found to be ubiquitous contaminants in the aquatic ecosystem. In particular, fish are considered by the scientific community to be the most feasible organism for contamination monitoring in aquatic ecosystems. Despite that, studies on the bioaccumulation of UV-F are scarce. In this study fish samples from four Iberian river basins under high anthropogenic pressure were analysed by liquid chromatography–tandem mass spectrometry (HPLC–MS/MS). Benzophenone-3 (BP3), ethylhexyl methoxycinnamate (EHMC), 4-methylbenzylidene camphor (4MBC) and octocrylene (OC) were the predominant pollutants in the fish samples, with concentrations in the range of ng/g dry weight (d.w.). The results indicated that most polluted area corresponded to Guadalquivir River basin, where maximum concentrations were found for EHMC (241.7 ng/g d.w.). Sediments from this river basin were also analysed. Lower values were observed in relation to fish for OC and EHMC, ranging from below the limits of detection to 23 ng/g d.w. Accumulation levels of UV-F in the fish were used to calculate biota-sediment accumulation factors (BSAFs). These values were always below 1, in the range of 0.04–0.3, indicating that the target UV-Fs are excreted by fish only to some extent. The fact that the highest concentrations were determined in predators suggests that biomagnification of UV-F may take place along the freshwater food web. - Highlights: • First evidence of UV filters in fish from Iberian rivers • Biota-sediment accumulation factors (BSAFs) were always below 1. • Predator species presented higher UV-F concentrations suggesting trophic magnification

  17. Observational Evidence Linking Interstellar UV Absorption to PAH Molecules

    Energy Technology Data Exchange (ETDEWEB)

    Blasberger, Avi; Behar, Ehud; Perets, Hagai B. [Department of Physics, Technion (Israel); Brosch, Noah [The Wise Observatory and School of Physics and Astronomy, Tel Aviv University (Israel); Tielens, Alexander G. G. M. [Leiden Observatory, Leiden University (Netherlands)

    2017-02-20

    The 2175 Å UV extinction feature was discovered in the mid-1960s, yet its physical origin remains poorly understood. One suggestion is absorption by polycyclic aromatic hydrocarbon (PAH) molecules, which is supported by theoretical molecular structure computations and by laboratory experiments. PAHs are positively detected by their 3.3, 6.2, 7.7, 8.6, 11.3, and 12.7 μ m IR emission bands, which are specified by their modes of vibration. A definitive empirical link between the 2175 Å UV extinction and the IR PAH emission bands, however, is still missing. We present a new sample of hot stars that have both 2175 Å absorption and IR PAH emission. We find significant shifts of the central wavelength of the UV absorption feature, up to 2350 Å, but predominantly in stars that also have IR PAH emission. These UV shifts depend on stellar temperature in a fashion that is similar to the shifts of the 6.2 and 7.7 μ m IR PAH bands, that is, the features are increasingly more redshifted as the stellar temperature decreases, but only below ∼15 kK. Above 15 kK both UV and IR features retain their nominal values. Moreover, we find a suggestive correlation between the UV and IR shifts. We hypothesize that these similar dependences of both the UV and IR features on stellar temperature hint at a common origin of the two in PAH molecules and may establish the missing link between the UV and IR observations. We further suggest that the shifts depend on molecular size, and that the critical temperature of ∼15 kK above which no shifts are observed is related to the onset of UV-driven hot-star winds and their associated shocks.

  18. Observational Evidence Linking Interstellar UV Absorption to PAH Molecules

    International Nuclear Information System (INIS)

    Blasberger, Avi; Behar, Ehud; Perets, Hagai B.; Brosch, Noah; Tielens, Alexander G. G. M.

    2017-01-01

    The 2175 Å UV extinction feature was discovered in the mid-1960s, yet its physical origin remains poorly understood. One suggestion is absorption by polycyclic aromatic hydrocarbon (PAH) molecules, which is supported by theoretical molecular structure computations and by laboratory experiments. PAHs are positively detected by their 3.3, 6.2, 7.7, 8.6, 11.3, and 12.7 μ m IR emission bands, which are specified by their modes of vibration. A definitive empirical link between the 2175 Å UV extinction and the IR PAH emission bands, however, is still missing. We present a new sample of hot stars that have both 2175 Å absorption and IR PAH emission. We find significant shifts of the central wavelength of the UV absorption feature, up to 2350 Å, but predominantly in stars that also have IR PAH emission. These UV shifts depend on stellar temperature in a fashion that is similar to the shifts of the 6.2 and 7.7 μ m IR PAH bands, that is, the features are increasingly more redshifted as the stellar temperature decreases, but only below ∼15 kK. Above 15 kK both UV and IR features retain their nominal values. Moreover, we find a suggestive correlation between the UV and IR shifts. We hypothesize that these similar dependences of both the UV and IR features on stellar temperature hint at a common origin of the two in PAH molecules and may establish the missing link between the UV and IR observations. We further suggest that the shifts depend on molecular size, and that the critical temperature of ∼15 kK above which no shifts are observed is related to the onset of UV-driven hot-star winds and their associated shocks.

  19. Comparison of various liquid chromatographic methods involving UV and atmospheric pressure chemical ionization mass spectrometric detection for the efficient trace analysis of phenylurea herbicides in various types of water samples.

    Science.gov (United States)

    van der Heeft, E; Dijkman, E; Baumann, R A; Hogendoorn, E A

    2000-05-19

    The performance of mass spectrometric (MS) detection and UV detection in combination with reversed-phase liquid chromatography without and with the use of coupled column RPLC (LC-LC) has been compared for the trace analysis of phenylurea herbicides in environmental waters. The selected samples of this comparative study originated from an inter-laboratory study. For both detection modes, a 50 mm x 4.6 mm I.D. column and a 100 mm x 4.6 mm I.D. column packed with 3 microm C18 were used as the first (C-1) and second (C-2) column, respectively. Atmospheric pressure chemical ionization mass spectrometry was performed on a magnetic sector instrument. The LC-LC-MS analysis was carried out on-line by means of direct large volume (11.7 ml) injection (LVI). The performance of both on-line (LVI, 4 ml of sample) and off-line LC-LC-UV (244 nm) analysis was investigated. The latter procedure consisted of a solid-phase extraction (SPE) of 250 ml of water sample on a 500 mg C18 cartridge. The comparative study showed that LC-LC-MS is more selective then LC-LC-UV and, in most cases, more sensitive. The LVI-LC-LC-MS approach combines direct quantification and confirmation of most of the analytes down to a level of 0.01 microg/l in water samples in less then 30 min. As regards LC-LC-UV, the off-line method appeared to be a more viable approach in comparison with the on-line procedure. This method allows the screening of phenylurea's in various types of water samples down to a level of at least 0.05 microg/l. On-line analysis with LVI provided marginal sensitivity (limits of detection of about 0.1 microg/l) and selectivity was sometimes less in case of surface water samples. Both the on-line LVI-LC-LC-MS method and the LC-LC-UV method using off-line SPE were validated by analysing a series of real-life reference samples. These samples were part of an inter-laboratory test and contained residues of herbicides ranging from 0.02 to 0.8 microg/l. Beside good correlation between the methods

  20. Evaluation of electrochemical, UV/VIS and Raman spectroelectrochemical detection of Naratriptan with screen-printed electrodes.

    Science.gov (United States)

    Hernández, Carla Navarro; Martín-Yerga, Daniel; González-García, María Begoña; Hernández-Santos, David; Fanjul-Bolado, Pablo

    2018-02-01

    Naratriptan, active pharmaceutical ingredient with antimigraine activity was electrochemically detected in untreated screen-printed carbon electrodes (SPCEs). Cyclic voltammetry and differential pulse voltammetry were used to carry out quantitative analysis of this molecule (in a Britton-Robinson buffer solution at pH 3.0) through its irreversible oxidation (diffusion controlled) at a potential of +0.75V (vs. Ag pseudoreference electrode). Naratriptan oxidation product is an indole based dimer with a yellowish colour (maximum absorption at 320nm) so UV-VIS spectroelectrochemistry technique was used for the very first time as an in situ characterization and quantification technique for this molecule. A reflection configuration approach allowed its measurement over the untreated carbon based electrode. Finally, time resolved Raman Spectroelectrochemistry is used as a powerful technique to carry out qualitative and quantitative analysis of Naratriptan. Electrochemically treated silver screen-printed electrodes are shown as easy to use and cost-effective SERS substrates for the analysis of Naratriptan. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Gamma-ray detection with an UV-enhanced photodiode and scintillation crystals emitting at short wavelengths

    International Nuclear Information System (INIS)

    Johansen, G.A.

    1997-01-01

    A low-noise ion implanted photodiode with high spectral response in the deep blue/UV region has been tested as read-out device for scintillation crystals with matching emission spectra (YAP(Ce), GSO(Ce), BGO and CsI(Tl)). This gamma-ray detector concept is attractive in many industrial applications where compactness, reliability and ambient temperature operation are important. The results show that the amount of detected scintillation light energy falls rapidly off as the wavelength of the scintillation light decreases. It is concluded that the dynamic spectral response of the photodiode, due to increasing carrier collection times, is considerably less than the DC response at short wavelengths. The diode is not useful in pulse mode operation with scintillation crystals emitting at wavelengths below about 400 nm. For read-out of CsI(Tl) with 661.6 keV gamma-radiation, however, the photodiode concept shows better energy resolution (7.1%) than other detectors. (orig.)

  2. The spectrophotometric determination of boron in tourmalines

    Directory of Open Access Journals (Sweden)

    LJILJANA JAKSIC

    2005-02-01

    Full Text Available A procedure for the spectrophotometric determination of macro amounts of boron in tourmaline with azomethine H is described. The used tourmaline concentrate was obtained by magnetic separation and heavy-liquids purification of the schorl zone of pegmatite or granite aplite. The samples of tourmaline were decomposed by fusion with anhydrous sodium carbonate and taken up in dilute hydrochloric acid. The interfering effects of iron and aluminium were eliminated by masking with an EDTA – NTA solution. After pH adjustment, the boron was reacted with azomethine H and the absorbance of the obtained coloured complex was measured at 415 nm. The results are compared with those obtained by other procedures. The relative error of the determination was less than 3 %.

  3. Determinação de proteínas totais via espectrofometria: vantagens e desvantagens dos métodos existentes Determination of total protein by spectrophotometry: advantages and disadvantages of proposed methods

    Directory of Open Access Journals (Sweden)

    Dimas A. M. Zaia

    1998-11-01

    Full Text Available Spectrophotometric determination of total protein is used in several areas such as clinical analysis, food science and technology, biochemistry, protein chemistry, physiology. Five spectrophotometric methods are mostly used: biuret, Lowry, Bradford, Smith and UV absorption. In this review a general overview of these methods is presented (interferences, applications; other methodologies are also discussed.

  4. DNA damage caused by UV- and near UV-irradiation

    International Nuclear Information System (INIS)

    Ohnishi, Takeo

    1986-01-01

    Much work with mutants deficient in DNA repair has been performed concerning UV-induced DNA damage under the condition where there is no artificial stimulation. In an attempt to infer the effects of solar wavelengths, the outcome of the work is discussed in terms of cellular radiation sensitivity, unscheduled DNA synthesis, and mutation induction, leading to the conclusion that some DNA damage occurs even by irradiation of the shorter wavelength light (270 - 315 nm) and is repaired by excision repair. It has been thought to date that pyrimidine dimer (PD) plays the most important role in UV-induced DNA damage, followed by (6 - 4) photoproducts. As for DNA damage induced by near UV irradiation, the yield of DNA single-strand breaks and of DNA-protein crosslinking, other than PD, is considered. The DNA-protein crosslinking has proved to be induced by irradiation at any wavelength of UV ranging from 260 to 425 nm. Near UV irradiation causes the inhibition of cell proliferation to take place. (Namekawa, K.)

  5. Piezo-Phototronic Enhanced UV Sensing Based on a Nanowire Photodetector Array.

    Science.gov (United States)

    Han, Xun; Du, Weiming; Yu, Ruomeng; Pan, Caofeng; Wang, Zhong Lin

    2015-12-22

    A large array of Schottky UV photodetectors (PDs) based on vertical aligned ZnO nanowires is achieved. By introducing the piezo-phototronic effect, the performance of the PD array is enhanced up to seven times in photoreponsivity, six times in sensitivity, and 2.8 times in detection limit. The UV PD array may have applications in optoelectronic systems, adaptive optical computing, and communication. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. In situ spectrophotometric measurement of dissolved inorganic carbon in seawater

    Science.gov (United States)

    Liua, Xuewu; Byrne, Robert H.; Adornato, Lori; Yates, Kimberly K.; Kaltenbacher, Eric; Ding, Xiaoling; Yang, Bo

    2013-01-01

    Autonomous in situ sensors are needed to document the effects of today’s rapid ocean uptake of atmospheric carbon dioxide (e.g., ocean acidification). General environmental conditions (e.g., biofouling, turbidity) and carbon-specific conditions (e.g., wide diel variations) present significant challenges to acquiring long-term measurements of dissolved inorganic carbon (DIC) with satisfactory accuracy and resolution. SEAS-DIC is a new in situ instrument designed to provide calibrated, high-frequency, long-term measurements of DIC in marine and fresh waters. Sample water is first acidified to convert all DIC to carbon dioxide (CO2). The sample and a known reagent solution are then equilibrated across a gas-permeable membrane. Spectrophotometric measurement of reagent pH can thereby determine the sample DIC over a wide dynamic range, with inherent calibration provided by the pH indicator’s molecular characteristics. Field trials indicate that SEAS-DIC performs well in biofouling and turbid waters, with a DIC accuracy and precision of ∼2 μmol kg–1 and a measurement rate of approximately once per minute. The acidic reagent protects the sensor cell from biofouling, and the gas-permeable membrane excludes particulates from the optical path. This instrument, the first spectrophotometric system capable of automated in situ DIC measurements, positions DIC to become a key parameter for in situ CO2-system characterizations.

  7. Evaluation of the Esthetic Properties of Developmental Defects of Enamel: A Spectrophotometric Clinical Study

    Directory of Open Access Journals (Sweden)

    Fabrizio Guerra

    2015-01-01

    Full Text Available Objectives. Detailed clinical quantification of optical properties of developmental defect of enamel is possible with spectrophotometric evaluation. Developmental defects of enamel (DDE are daily encountered in clinical practice. DDE are an alteration in quality and quantity of the enamel, caused by disruption and/or damage to the enamel organ during amelogenesis. Methods. Several clinical indices have been developed to categorize enamel defects based on their nature, appearance, microscopic features, or cause. A sample of 39 permanent teeth presenting DDE on labial surface was examined using the DDE Modified Index and SpectroShade evaluation. The spectrophotometric approach quantifies L* (luminosity, a* (quantity of green-red, and b* (quantity of blue-yellow of different DDE. Conclusions. SpectroShade evaluation of the optical properties of the enamel defect enhances clinical understanding of severity and extent of the defect and characterizes the enamel alteration in terms of color discrepancy and surface characterization.

  8. Dopantless Diodes for Efficient Mid/deep UV LEDs and Lasers - Topic 4.2 Optoelectronics

    Science.gov (United States)

    2017-09-12

    UVB/UVC solid state emitters is a rapidly growing market – UV curing of adhesives – Water disinfection – Chemical Agent detection • Replacement of...recombination • Electron leakage • Junction heating ~3.5× EL in TJ LEDS ~2× EL @ 180 A/cm2 DC measurements; 0.1mm×0.1mm 29 Increased wall plug efficiency 0...market – UV curing of adhesives – Water disinfection – Chemical Agent detection • Replacement of bulky, toxic Hg arc lamps • Applications require high

  9. Removal of pharmaceutically active compounds from synthetic and real aqueous mixtures and simultaneous disinfection by supported TiO2/UV-A, H2O2/UV-A, and TiO2/H2O2/UV-A processes.

    Science.gov (United States)

    Bosio, Morgana; Satyro, Suéllen; Bassin, João Paulo; Saggioro, Enrico; Dezotti, Márcia

    2018-05-01

    Pharmaceutically active compounds are carried into aquatic bodies along with domestic sewage, industrial and agricultural wastewater discharges. Psychotropic drugs, which can be toxic to the biota, have been detected in natural waters in different parts of the world. Conventional water treatments, such as activated sludge, do not properly remove these recalcitrant substances, so the development of processes able to eliminate these compounds becomes very important. Advanced oxidation processes are considered clean technologies, capable of achieving high rates of organic compounds degradation, and can be an efficient alternative to conventional treatments. In this study, the degradation of alprazolam, clonazepam, diazepam, lorazepam, and carbamazepine was evaluated through TiO 2 /UV-A, H 2 O 2 /UV-A, and TiO 2 /H 2 O 2 /UV-A, using sunlight and artificial irradiation. While using TiO 2 in suspension, best results were found at [TiO 2 ] = 0.1 g L -1 . H 2 O 2 /UV-A displayed better results under acidic conditions, achieving from 60 to 80% of removal. When WWTP was used, degradation decreased around 50% for both processes, TiO 2 /UV-A and H 2 O 2 /UV-A, indicating a strong matrix effect. The combination of both processes was shown to be an adequate approach, since removal increased up to 90%. H 2 O 2 /UV-A was used for disinfecting the aqueous matrices, while mineralization was obtained by TiO 2 -photocatalysis.

  10. RNA synthesis during germination of UV-irradiated Dictyostelium discoideum spores

    International Nuclear Information System (INIS)

    Okaichi, Kumio

    1987-01-01

    UV irradiation to the spores of Dictyostelium discoideum NC4 resulted in a more prolonged delay of amoeba-emergence from swollen spores with increasing UV fluence. During the germination, an inhibition of total RNA synthesis and a shift of stage of maximum RNA synthesis to the later period were observed. The maximum poly(A) + RNA synthetic activity was found on an early stage of amoeba-emergence prior about 1 h to the beginning of rRNA synthesis in unirradiated spore germination; but, in UV-irradiated spore germination, the stage of maximum poly(A) + RNA synthesis shifted to the later stage of germination with increasing UV fluence. A decreased synthesis of poly(A) + RNA and a severe inhibition of rRNA synthesis were observed on UV-irradiated and germinated spores, but no significant inhibition of 4 - 5 S RNA synthesis was detected. Actinomycin D suppressed almost completely the rRNA synthesis of emerged amoebae but the drug apparently did not affect the emergence of amoebae at any stage of germination. It was postulated that the delay of amoeba-emergence in UV-irradiated spore must be mainly due to the shift of the stage of maximum synthesis of poly(A) + RNA to the later stage of germination. (author)

  11. Applying UV cameras for SO2 detection to distant or optically thick volcanic plumes

    Science.gov (United States)

    Kern, Christoph; Werner, Cynthia; Elias, Tamar; Sutton, A. Jeff; Lübcke, Peter

    2013-01-01

    Ultraviolet (UV) camera systems represent an exciting new technology for measuring two dimensional sulfur dioxide (SO2) distributions in volcanic plumes. The high frame rate of the cameras allows the retrieval of SO2 emission rates at time scales of 1 Hz or higher, thus allowing the investigation of high-frequency signals and making integrated and comparative studies with other high-data-rate volcano monitoring techniques possible. One drawback of the technique, however, is the limited spectral information recorded by the imaging systems. Here, a framework for simulating the sensitivity of UV cameras to various SO2 distributions is introduced. Both the wavelength-dependent transmittance of the optical imaging system and the radiative transfer in the atmosphere are modeled. The framework is then applied to study the behavior of different optical setups and used to simulate the response of these instruments to volcanic plumes containing varying SO2 and aerosol abundances located at various distances from the sensor. Results show that UV radiative transfer in and around distant and/or optically thick plumes typically leads to a lower sensitivity to SO2 than expected when assuming a standard Beer–Lambert absorption model. Furthermore, camera response is often non-linear in SO2 and dependent on distance to the plume and plume aerosol optical thickness and single scatter albedo. The model results are compared with camera measurements made at Kilauea Volcano (Hawaii) and a method for integrating moderate resolution differential optical absorption spectroscopy data with UV imagery to retrieve improved SO2 column densities is discussed.

  12. Pollution patterns and underlying relationships of benzophenone-type UV-filters in wastewater treatment plants and their receiving surface water.

    Science.gov (United States)

    Wu, Ming-Hong; Li, Jian; Xu, Gang; Ma, Luo-Dan; Li, Jia-Jun; Li, Jin-Song; Tang, Liang

    2018-05-15

    The environmental behaviors of emerging pollutants, benzophenone-type UV filters (BP-UV filters) and their derivatives were investigated in four wastewater treatment plants (WWTPs), and their receiving surface waters in Shanghai. The concentration level of selected BP-UV filters in the WWTPs was detected from ngL -1 to μgL -1 . BP (621-951ngL -1 ) and BP-3 (841-1.32 × 10 3 ngL -1 ) were the most abundant and highest detection frequency individuals among the target BP-UV filters in influents, whereas BP (198-400ngL -1 ), BP-4 (93.3-288ngL -1 ) and BP-3 (146-258ngL -1 ) were predominant in effluents. BP-UV filters cannot be completely removed and the total removal efficiency varied widely (-456% to 100%) during the treatment process. It can be inferred that the usage of BP and BP-3 are higher than other BP-UV filters in the study area. The lowest and highest levels were BP-2 (ND-7.66ngL -1 ) and BP-3 (68.5-5.01 × 10 3 ng L -1 ) in the receiving surface water, respectively. Interestingly, the seasonal variation of BP-3 is larger than those of other BP-UV filters in surface water from Shanghai. There is no obvious pollution pattern of BP-UV filters in the surface water from the cosmetic factory area. The correlation analysis of BP-UV filters between WWTPs effluents and nearby downstream water samples suggested that BP-UV filters emitted from some WWTPs might be the main source of receiving surface water. Preliminary risk assessment indicated that the levels of BP-UV filters detected by the effluent posed medium to high risk to fish as well as other aquatic organisms. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Expression of UV-irradiated adenovirus in normal and UV-sensitive Chinese hamster ovary cells

    International Nuclear Information System (INIS)

    Rainbow, A.J.

    1985-01-01

    The chinese hamster ovary (CHO) cell mutants UV-20, UV-24, and UV-41 are abnormally sensitive to UV and harbour various defects lin their ability to repair cellular DNA. This study has examined the expression of UV-irradiated AD2 in these cells. HCR of UV-irradiated Ad2, as measured by viral structural antigen (Vag) formation or progeny production, was found to be similar for the normal and the UV-sensitive CHO strains. UV-irradiation of Ad2 (1200 J/m/sup 2/) resulted in a delay of Vag expression of 18 hours in normal human fibroblasts, which is thought to reflect the time required for removal of UV-induced lesions from the DNA before viral DNA synthesis can proceed. However, a similar UV-irradiation of Ad2 did not result in a delay of Vag expression for infection of CHO cells, suggesting that UV-induced lesions in Ad2 DNA do not inhibit its replication in CHO cells. These results indicate a fundamental difference in the processing of UV-irradiated AD2-DNA in CHO as compared to human cells

  14. An analytical method for determination of fullerenes and functionalized fullerenes in soils with high performance liquid chromatography and UV detection

    International Nuclear Information System (INIS)

    Carboni, Andrea; Emke, Erik; Parsons, John R.; Kalbitz, Karsten; Voogt, Pim de

    2014-01-01

    Graphical abstract: -- Highlights: •A total of eight fullerenes can be analyzed in a single run with HPLC-UV. •The method allows the analysis of fullerenes in soil at relatively low concentrations. •The method developed is robust, highly reproducible and relatively efficient. •The method can be applied to the study of the environmental fate and toxicology of fullerenes. -- Abstract: Fullerenes are carbon-based nanomaterials expected to play a major role in emerging nanotechnology and produced at an increasing rate for industrial and household applications. In the last decade a number of novel compounds (i.e. fullerene derivatives) is being introduced into the market and specific analytical methods are needed for analytical purposes as well as environmental and safety issues. In the present work eight fullerenes (C60 and C70) and functionalized fullerenes (C60 and C70 exohedral-derivatives) were selected and a novel liquid chromatographic method was developed for their analysis with UV absorption as a method of detection. The resulting HPLC-UV method is the first one suitable for the analysis of all eight compounds. This method was applied for the analysis of fullerenes added to clayish, sandy and loess top-soils at concentrations of 20, 10 and 5 μg kg −1 and extracted with a combination of sonication and shaking extraction. The analytical method limits of detection (LoD) and limits of quantification (LoQ) were in the range of 6–10 μg L −1 and 15–24 μg L −1 respectively for the analytical solutions. The extraction from soil was highly reproducible with recoveries ranging from 47 ± 5 to 71 ± 4% whereas LoD and LoQ for all soils tested were of 3 μg kg −1 and 10 μg kg −1 respectively. No significant difference in the extraction performance was observed depending of the different soil matrices and between the different concentrations. The developed method can be applied for the study of the fate and toxicity of fullerenes in complex matrices

  15. Immune response to UV-induced tumors: mediation of progressor tumor rejection by natural killer cells

    International Nuclear Information System (INIS)

    Streeter, P.R.; Fortner, G.W.

    1986-01-01

    Skin tumors induced in mice by chronic ultraviolet (UV) irradiation are highly antigenic and can induce a state of transplantation immunity in syngeneic animals. In the present study, the authors compared the in vitro cytolytic activity of splenic lymphocytes from mice immunized with either regressor or progressor UV-tumors. The results of this comparison implicated tumor-specific cytolytic T (Tc) lymphocytes in rejection of regressor UV-tumors, and revealed that immunization with the progressor UV-tumor 2237 failed to elicit detectable levels of progressor tumor-specific Tc cells even as the tumors rejected. Following in vitro resensitization of spleen cells from either regressor or progressor tumor immune animals, the authors found NK-like lymphocytes with anti-tumor activity. As the authors had not detected cells with this activity in splenic lymphocyte preparations prior to in vitro resensitization, the authors examined lymphocytes from the local tumor environment during the course of progressor tumor rejection for this activity. This analysis revealed NK lymphocytes exhibiting significant levels of cytolytic activity against UV-tumors. These results implicate NK cells as potential effector cells in the rejection of progressor UV-tumors by immune animals, and suggests that these cells may be regulated by T lymphocytes

  16. Índice UV

    Science.gov (United States)

    Información general sobre el Índice UV que proporciona un pronóstico del riesgo esperado de sobreexposición a la radiación ultravioleta (UV) del sol. El índice UV va acompañado de recomendaciones para protegerse del sol.

  17. Spectral dependence of some UV-B and UV-C responses of Tetrahymena pyriformis irradiated with dye laser generated UV

    International Nuclear Information System (INIS)

    Calkins, John; Colley, Ed; Wheeler, John; Kentucky Univ., Lexington

    1987-01-01

    We have generated UV-B and UV-C radiations using a flashlamp driven tunable dye laser combined with frequency doubling crystals. Using this novel UV source, we have investigated lethality and its modification by growth phase, photoreactivation and caffeine in Tetrahymena pyriformis at 254 nm and from 260-315 nm in 5 nm steps. From the observed responses we have constructed action spectra for lethality, with or without caffeine (a repair inhibitor) and under conditions of photoreactivation. We have also estimated quantum efficiencies for these responses. Our observations suggest that complex changes in response occur at several wavelengths over the UV-C and UV-B regions. (author)

  18. Readout of the UFFO Slewing Mirror Telescope to detect UV/optical photons from Gamma-Ray Bursts

    DEFF Research Database (Denmark)

    Kim, J. E.; Lim, H.; Nam, J. W.

    2013-01-01

    plane detector of Intensified Charge-Coupled Device (ICCD). The ICCD is sensitive to UV/optical photons of 200–650 nm in wavelength by using a UV-enhanced S20 photocathode and amplifies photoelectrons at a gain of 104–106 in double Micro-Channel Plates. These photons are read out by a Kodak KAI-0340...

  19. DNA repair synthesis in human skin exposed to ultraviolet radiation used in PUVA (psoralen and UV-A) therapy for psoriasis

    International Nuclear Information System (INIS)

    Bishop, S.C.

    1979-01-01

    The ultraviolet radiation used in psoralen and UV-A (PUVA) therapy stimulated DNA repair activity in normal human skin and in the uninvolved skin from psoriatic patients. The activity detected by autoradiography increased linearly with exposure time. No stimulation was observed when the UV-B component was removed from the incident radiation by filtration through glass. Therefore UV-B damage to DNA was found responsible for the activity detected following exposure to the unfiltered PUVA light source. (author)

  20. High precision spectrophotometric analysis of thorium

    International Nuclear Information System (INIS)

    Palmieri, H.E.L.

    1984-01-01

    An accurate and precise determination of thorium is proposed. Precision of about 0,1% is required for the determination of macroquantities of thorium when processed. After an extensive literature search concerning this subject, spectrophotometric titration has been chosen, using dissodium ethylenediaminetetraacetate (EDTA) solution and alizarin-S as indicator. In order to obtain such a precision, an amount of 0,025 M EDTA solution precisely measured has been added and the titration was completed with less than 5 ml of 0,0025 M EDTA solution. It is usual to locate the end-point graphically, by plotting added titrant versus absorbance. The non-linear minimum square fit, using the Fletcher e Powell's minimization process and a computer programme. Besides the equivalence point, other parameters of titration were determined: the indicator concentration, the absorbance of the metal-indicator complex, and the stability constants of the metal-indicator and the metal-EDTA complexes. (Author) [pt