WorldWideScience

Sample records for spect thallium imaging

  1. Effect of maintenance oral theophylline on dipyridamole-thallium-201 myocardial imaging using SPECT and dipyridamole-induced hemodynamic changes

    International Nuclear Information System (INIS)

    Daley, P.J.; Mahn, T.H.; Zielonka, J.S.; Krubsack, A.J.; Akhtar, R.; Bamrah, V.S.

    1988-01-01

    To evaluate the effect of maintenance oral theophylline therapy on the diagnostic efficacy of dipyridamole-thallium-201 single photon emission computed tomography (SPECT) imaging for coronary artery disease, dipyridamole-thallium-201 SPECT imaging was performed in eight men with documented coronary artery disease before initiation of theophylline treatment and repeated while these patients were receiving therapeutic doses of oral theophylline. Before theophylline treatment, intravenous dipyridamole caused a significant increase in heart rate, decrease in blood pressure, angina in seven of eight patients, and ST segment depression in four of eight patients. While they were being treated with theophylline, none of the patients had angina or ST segment depression, and there were no hemodynamic changes with intravenous dipyridamole. Before theophylline treatment, dipyridamole-thallium-201 SPECT imaging showed reversible perfusion defects in myocardial segments supplied by stenotic coronary arteries. With theophylline treatment, dipyridamole-thallium-201 SPECT showed total absence of reversible perfusion defects. Treatment with theophylline markedly reduced the diagnostic accuracy of dipyridamole-thallium-201 imaging for coronary artery disease

  2. Tc99m-Tetrofosmin and Thallium-201 SPECT imaging of pituitary tumors: Preliminary results

    International Nuclear Information System (INIS)

    Yarman, S.; Mudun, A.

    2002-01-01

    Aim: It has been reported that pituitary adenomas accumulate Thallium -201(Tl-201), Tc99m-sestamibi and In111-Octreotide. These agents maybe useful in the diagnosis and follow-up of pituitary adenomas. Tc99m-tetrofosmin also has been shown as an tumor seeking agent in various tumors. The aim of this study is to evaluate the accumulation of Tc99m-tetrofosmin in pituitary adenomas and compare the results to Tl-201 SPECT. Methods: We performed Tc99m-Tetrofosmin and Tl-201 SPECT imaging on 5 patients (pts) with pituitary tumors, 3 patients with acromegaly, 1 patient with macro prolactinoma, and 1 patient with nonfunctional tumor (1 female, 4 male, age range: 26-50). SPECT imaging of cranium were obtained 20 min after intravenous injection of 111 MBq Tl-201 and 555 MBq Tc99m-Tetrofosmin on different days with a dual head gamma camera. All but one patient had surgical therapy. One patient had medical treatment. One patient had post surgical imaging with both Tetrofosmin and Tl-201 and 2 pts had only with Thallium. Semiquantitative analysis were performed by calculating tumor to background ratio from the mean counts of the created ROI's. Results: All adenomas showed prominent uptake with both Thallium and Tetrofosmin. The mean tumor to background ratios were 2.3 (range: 1.2-4.29) with Thallium and 3.57 (range: 1.6-6.86) with Tetrofosmin. Post therapy images showed no significant uptake in pituitary region with both agents in 2 patients. Post therapy mean Thallium uptake ratio in 3 pts was 1.64. One patient with acromegaly showed no decrease in thallium uptake, but showed some decrease in tetrofosmin uptake. Conclusion: Although our patient number is limited, these preliminary results indicate that Tc99m-tetrofosmin has also strong affinity for pituitary adenomas as does Thallium, either the adenoma is functioning or non-functioning. It may have a potential value to evaluate the response to therapy

  3. Peritoneal fluid causing inferior attenuation on SPECT thallium-201 myocardial imaging in women

    International Nuclear Information System (INIS)

    Rab, S.T.; Alazraki, N.P.; Guertler-Krawczynska, E.

    1988-01-01

    On SPECT thallium images, myocardial left ventricular (LV) anterior wall attenuation due to breast tissue is common in women. In contrast, in men, inferior wall counts are normally decreased compared to anterior counts. The purpose of this report is to describe cases of inferior wall attenuation of counts in women caused by peritoneal fluid, not myocardial disease. Twelve consecutive SPECT thallium myocardial studies performed in women on peritoneal dialysis, being evaluated for kidney transplant, were included in this study. For all studies, 3.5 mCi 201Tl were injected intravenously. Thirty-two images were acquired over 180 degrees (45 degrees RAO progressing to 45 degrees LPO) at 40 sec per stop. SPECT images were reviewed in short axis, horizontal long and vertical long axes. Data were also displayed in bullseye format with quantitative comparison to gender-matched normal files. Ten of 12 female patients studied had inferior wall defects on images, confirmed by bullseye display. All patients had approximately 2 liters of peritoneal fluid. Review of planar rotational views showed diaphragm elevation and fluid margin attenuations affecting left ventricular inferior wall. Thus, peritoneal fluid is a cause of inferior attenuation on 201Tl cardiac imaging

  4. Clinical evaluation of stress thallium spect in ischemic heart disease

    International Nuclear Information System (INIS)

    Sui, Osamu; Kimura, Nazuna; Soeki; Takeshi; Takeichi, Naoki; Shinohara, Hisanori; Tamura, Yoshiyuki; Fukuda, Nobuo

    1997-01-01

    Thallium SPECT was performed in patients with significant coronary artery stenosis, 67 cases were after maximal exercise and 74 cases were during coronary vasodilation induced by ATP (adenosine triphosphate) infusion. In patients suspected of angina pectoris, the sensitivity, specificity and predictive accuracy for detection of coronary artery disease (CAD) were 88%, 78% and 82% for exercise SPECT, and 100%, 72% and 84% for ATP SPECT studies, respectively. In patients with old myocardial infarction, these were 73%, 100% and 88% for exercise SPECT and 71%, 100% and 81% for ATP SPECT. These were 75%, 49% and 60% for treadmill exercise test in the patient group including both angina and myocardial infarction. For detection of diseased vessels, the diagnostic accuracy for left anterior descending artery and right coronary artery lesions was almost equal for ATP and exercise SPECT study, but ATP SPECT study was more sensitive than exercise SPECT study in detection of left circumflex artery lesions. ATP as well as exercise SPECT studies occasionally gave false positive results in patients with single-vessel disease. ATP as well as exercise SPECT studies underestimated the severity of multi-vessel disease. In general, the results of ATP SPECT imaging were highly concordant with the results of exercise SPECT imaging. ATP stress thallium SPECT imaging provided a safe and highly accurate diagnostic tool for detection of CAD. (author)

  5. Rapid gated Thallium-201 perfusion SPECT - clinically feasible?

    International Nuclear Information System (INIS)

    Wadhwa, S.S.; Mansberg, R.; Fernandes, V.B.; Wilkinson, D.; Abatti, D.

    1998-01-01

    Full text: Standard dose energy window optimised Thallium-201 (Tl-201) SPECT has about half the counts of a standard dose from Technetium-99m Sestamibi (Tc99m-Mibi) gated perfusion SPECT. This study investigates the clinical feasibility of rapid energy window optimised Tl-201 gated perfusion SPECT (gated-TI) and compares quantitative left ventricular ejection fraction (LVEF) and visually assessed image quality for wall motion and thickening to analogous values obtained from Tc99m-Mibi gated perfusion SPECT (gated - mibi). Methods: We studied 60 patients with a rest gated Tl-201 SPECT (100 MBq, 77KeV peak, 34% window, 20 sec/projection) followed by a post stress gated Sestamibi SPECT (1GBq, 140KeV, 20% window, 20 sec/projection) separate dual isotope protocol. LVEF quantitation was performed using commercially available software (SPECTEF, General Electric). Visual grading of image quality for wall thickening and motion was performed using a three-point scale (excellent, good and poor). Results: LVEF for gated Tl-201 SPECT was 59.6 ± 12.0% (Mean ± SD). LVEF for gated Sestamibi SPECT was 60.4 ±11.4% (Mean ± SD). These were not significantly different (P=0.27, T-Test). There was good correlation (r=0.9) between gated-TI and gated-mibi LVEF values. The quality of gated-Tl images was ranked as excellent, good and poor in 12, 50 and 38% of the patients respectively. Image quality was better in gated-mibi SPECT, with ratings of 12, 62 and 26% respectively. Conclusion: Rapid gated Thallium-201 acquisition with energy window optimisation can be effectively performed on majority of patients and offers the opportunity to assess not only myocardial perfusion and function, as with Technetium based agents, but also viability using a single day one isotope protocol

  6. Comparison of diagnostic value of coronary artery disease between ATP-stress and exercise-stress thallium myocardial SPECT images

    International Nuclear Information System (INIS)

    Suzuki, Shigeo

    1994-01-01

    A study was made between adenosine triphosphate disodium (ATP)-stress thallium myocardial scintigrams and exercise-stress scintigrams to compare their respective extents and degree of defects. The subjects of the study were 33 ischemic heart disease patients, who received ATP stress and treadmill exercise stress with a mean interval of 25 days. ATP was infused for 5 minutes with an infusion rate of 0.16 or 0.18 mg per kg of body weight per minute. Thallium was injected three minutes after infusion. The percent-defect index (percentage of the extent and degree of the defects for all 33 patients), was calculated with visual scoring using a five-zone myocardial division method and semi-quantitative four-grade representation method for both the ATP and exercise SPECT images. The extent of the defects in ATP- and exercise-stress images was 51.5% and 44.2%, and that in redistribution images was 36.4% and 33.9%, respectively. The degree of defects in ATP- and exercise-stress images was 35.8% and 32.3%, while that in redistribution images was 20.8% and 17.2%, respectively (p=NS in all cases). In conclusion, the image quality of thallium SPECT with ATP stress was equivalent that of exercise stress, indicating identical diagnostic values for coronary lesions. (author)

  7. [Performance of Thallium 201 rest-redistribution spect to predict viability in recent myocardial infarction].

    Science.gov (United States)

    Coll, Claudia; González, Patricio; Massardo, Teresa; Sierralta, Paulina; Humeres, Pamela; Jofré, Josefina; Yovanovich, Jorge; Aramburú, Ivonne; Brugère, Solange; Chamorro, Hernán; Ramírez, Alfredo; Kunstmann, Sonia; López, Héctor

    2002-03-01

    The detection of viability after acute myocardial infarction is primordial to select the most appropriate therapy, to decrease cardiac events and abnormal remodeling. Thallium201 SPECT is one of the radionuclide techniques used to detect viability. To evaluate the use of Thallium201 rest-redistribution SPECT to detect myocardial viability in reperfused patients after a recent myocardial infarction. Forty one patients with up to of 24 days of evolution of a myocardial infarction were studied. All had angiographically demonstrated coronary artery disease and were subjected to a successful thrombolysis, angioplasty or bypass grafting. SPECT Thallium201 images were acquired at rest and after 4 h of redistribution. These results were compared with variations in wall motion score, studied at baseline and after 3 or 4 months with echocardiography. The sensitivity of rest-redistribution Thallium201 SPECT, to predict recovery of wall motion was 91% when patient analysis was performed and 79% when segmental analysis was done in the culprit region. The figures for specificity were 56 and 73% respectively. Rest-distribution Thallium201 SPECT has an excellent sensitivity to predict myocardial viability in recent myocardial infarction. The data obtained in this study is similar to that reported for chronic coronary artery disease.

  8. Biphasic thallium 201 SPECT-imaging for the noninvasive diagnosis of myocardial perfusion abnormalities in a child with Kawasaki disease--a case report

    International Nuclear Information System (INIS)

    Hausdorf, G.; Nienaber, C.A.; Spielman, R.P.

    1988-01-01

    The mucocutaneous lymph node syndrome (Kawasaki disease) is of increasing importance for the pediatric cardiologist, for coronary aneurysms with the potential of thrombosis and subsequent stenosis can develop in the course of the disease. The authors report a 2 1/2-year-old female child in whom, fourteen months after the acute phase of Kawasaki disease, myocardial infarction occurred. Biphasic thallium 201 SPECT-imaging using dipyridamole depicted anterior wall ischemia and inferolateral infarction. This case demonstrates that noninvasive vasodilation-redistribution thallium 201 SPECT-imaging has the potential to predict reversible myocardial perfusion defects and myocardial necrosis, even in small infants with Kawasaki disease

  9. IQ-SPECT for thallium-201 myocardial perfusion imaging: effect of normal databases on quantification.

    Science.gov (United States)

    Konishi, Takahiro; Nakajima, Kenichi; Okuda, Koichi; Yoneyama, Hiroto; Matsuo, Shinro; Shibutani, Takayuki; Onoguchi, Masahisa; Kinuya, Seigo

    2017-07-01

    Although IQ-single-photon emission computed tomography (SPECT) provides rapid acquisition and attenuation-corrected images, the unique technology may create characteristic distribution different from the conventional imaging. This study aimed to compare the diagnostic performance of IQ-SPECT using Japanese normal databases (NDBs) with that of the conventional SPECT for thallium-201 ( 201 Tl) myocardial perfusion imaging (MPI). A total of 36 patients underwent 1-day 201 Tl adenosine stress-rest MPI. Images were acquired with IQ-SPECT at approximately one-quarter of the standard time of conventional SPECT. Projection data acquired with the IQ-SPECT system were reconstructed via an ordered subset conjugate gradient minimizer method with or without scatter and attenuation correction (SCAC). Projection data obtained using the conventional SPECT were reconstructed via a filtered back projection method without SCAC. The summed stress score (SSS) was calculated using NDBs created by the Japanese Society of Nuclear Medicine working group, and scores were compared between IQ-SPECT and conventional SPECT using the acquisition condition-matched NDBs. The diagnostic performance of the methods for the detection of coronary artery disease was also compared. SSSs were 6.6 ± 8.2 for the conventional SPECT, 6.6 ± 9.4 for IQ-SPECT without SCAC, and 6.5 ± 9.7 for IQ-SPECT with SCAC (p = n.s. for each comparison). The SSS showed a strong positive correlation between conventional SPECT and IQ-SPECT (r = 0.921 and p IQ-SPECT with and without SCAC was also good (r = 0.907 and p IQ-SPECT without SCAC; and 88.5, 86.8, and 87.3%, respectively, for IQ-SPECT with SCAC, respectively. The area under the curve obtained via receiver operating characteristic analysis were 0.77, 0.80, and 0.86 for conventional SPECT, IQ-SPECT without SCAC, and IQ-SPECT with SCAC, respectively (p = n.s. for each comparison). When appropriate NDBs were used, the diagnostic performance of 201 Tl IQ-SPECT

  10. Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT/CT: IQ-SPECT versus conventional protocols in normal subjects.

    Science.gov (United States)

    Matsuo, Shinro; Nakajima, Kenichi; Onoguchi, Masahisa; Wakabayash, Hiroshi; Okuda, Koichi; Kinuya, Seigo

    2015-06-01

    A novel multifocal collimator, IQ-SPECT (Siemens) consists of SMARTZOOM, cardio-centric and 3D iterative SPECT reconstruction and makes it possible to perform MPI scans in a short time. The aims are to delineate the normal uptake in thallium-201 ((201)Tl) SPECT in each acquisition method and to compare the distribution between new and conventional protocol, especially in patients with normal imaging. Forty patients (eight women, mean age of 75 years) who underwent myocardial perfusion imaging were included in the study. All patients underwent one-day protocol perfusion scan after an adenosine-stress test and at rest after administering (201)Tl and showed normal results. Acquisition was performed on a Symbia T6 equipped with a conventional dual-headed gamma camera system (Siemens ECAM) and with a multifocal SMARTZOOM collimator. Imaging was performed with a conventional system followed by IQ-SPECT/computed tomography (CT). Reconstruction was performed with or without X-ray CT-derived attenuation correction (AC). Two nuclear physicians blinded to clinical information interpreted all myocardial perfusion images. A semi-quantitative myocardial perfusion was analyzed by a 17-segment model with a 5-point visual scoring. The uptake of each segment was measured and left ventricular functions were analyzed by QPS software. IQ-SPECT provided good or excellent image quality. The quality of IQ-SPECT images without AC was similar to those of conventional LEHR study. Mid-inferior defect score (0.3 ± 0.5) in the conventional LEHR study was increased significantly in IQ-SPECT with AC (0 ± 0). IQ-SPECT with AC improved the mid-inferior decreased perfusion shown in conventional images. The apical tracer count in IQ-SPECT with AC was decreased compared to that in LEHR (0.1 ± 0.3 vs. 0.5 ± 0.7, p IQ-SPECT was significantly higher than that from the LEHR collimator (p = 0.0009). The images of IQ-SPECT acquired in a short time are equivalent to that of conventional LEHR

  11. Characteristics of images of angiographically proven normal coronary arteries acquired by adenosine-stress thallium-201 myocardial perfusion SPECT/CT-IQ[Symbol: see text]SPECT with CT attenuation correction changed stepwise.

    Science.gov (United States)

    Takahashi, Teruyuki; Tanaka, Haruki; Kozono, Nami; Tanakamaru, Yoshiki; Idei, Naomi; Ohashi, Norihiko; Ohtsubo, Hideki; Okada, Takenori; Yasunobu, Yuji; Kaseda, Shunichi

    2015-04-01

    Although several studies have shown the diagnostic and prognostic value of CT-based attenuation correction (AC) of single photon emission computed tomography (SPECT) images for diagnosing coronary artery disease (CAD), this issue remains a matter of debate. To clarify the characteristics of CT-AC SPECT images that might potentially improve diagnostic performance, we analyzed images acquired using adenosine-stress thallium-201 myocardial perfusion SPECT/CT equipped with IQ[Symbol: see text]SPECT (SPECT/CT-IQ[Symbol: see text]SPECT) from patients with angiographically proven normal coronary arteries after changing the CT attenuation correction (CT-AC) in a stepwise manner. We enrolled 72 patients (Male 36, Female 36) with normal coronary arteries according to findings of invasive coronary angiography or CT-angiography within three months after a SPECT/CT study. Projection images were reconstructed at CT-AC values of (-), 40, 60, 80 and 100 % using a CT number conversion program according to our definition and analyzed using polar maps according to sex. CT attenuation corrected segments were located from the mid- and apical-inferior spread through the mid- and apical-septal regions and finally to the basal-anterior and basal- and mid-lateral regions in males, and from the mid-inferior region through the mid-septal and mid-anterior, and mid-lateral regions in females as the CT-AC values increased. Segments with maximal mean counts shifted from the apical-anterior to mid-anterolateral region under both stress and rest conditions in males, whereas such segments shifted from the apical-septal to the mid-anteroseptal region under both stress and rest conditions in females. We clarified which part of the myocardium and to which degree CT-AC affects it in adenosine-stress thallium-201 myocardial perfusion SPECT/CT-IQ[Symbol: see text]SPECT images by changing the CT-AC value stepwise. We also identified sex-specific shifts of segments with maximal mean counts that changed as

  12. Submaximal exercise thallium-201 SPECT for assessment of interventional therapy in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Stewart, R.E.; Kander, N.; Juni, J.E.; Ellis, S.G.; O'Neill, W.W.; Schork, M.A.; Topol, E.J.; Schwaiger, M.

    1991-01-01

    Submaximal thallium-201 stress testing has been shown to provide important diagnostic and prognostic information in patients with acute myocardial infarction. The purpose of this investigation was to evaluate the diagnostic value of early submaximal stress testing and thallium-201 single photon emission computed tomography (SPECT) after interventional therapy. Scintigraphic results from 56 patients with infarctions, who underwent acute thrombolytic therapy, angioplasty, or both, were compared with late (6 weeks) functional outcome as assessed by radionuclide ventriculography and with results of discharge coronary angiography. A linear correlation was found between the extent of thallium-201 SPECT perfusion defect and late ventricular function (r = 0.74, p less than 0.01). Forty-two percent of patients with large SPECT perfusion defects had normal left ventricular ejection fractions, suggesting an overestimation of infarct size by early imaging. Sensitivity and specificity of thallium-201 SPECT for detection of coronary artery stenosis in noninfarct territories was 57% and 46%, respectively, indicating limited diagnostic definition of extent of underlying coronary artery disease. Results of follow-up coronary angiography showed a significant relationship between the size of the initial perfusion defect and early restenosis or reocclusion of the infarct artery. Thus the extent of early thallium-201 perfusion defects correlates with late functional outcome but appears to overestimate the degree of injury. Submaximal thallium-201 stress testing allows only limited characterization of underlying coronary artery disease. Early assessment of infarct size may identify a patient population at high risk for reocclusion of the infarct artery

  13. 201Thallium SPECT, accuracy in astrocytoma diagnosis and treatment evaluation

    International Nuclear Information System (INIS)

    Kaellen, K.

    1999-10-01

    The aims of the studies included in this thesis were: - to investigate the reliability of 201 Thallium single photon emission computed tomography. Tl SPECT for preoperative diagnosis and histological staging of malignant astrocytomas in comparison with CT; - to develop a method for quantification of cerebral thallium uptake, and to evaluate the quantitative measurement in comparison with CT, for astrocytoma treatment follow-up purposes; - to compare quantitative Tl SPECT and proton magnetic resonance spectroscopy (H-MRS) with conventional MR imaging for astrocytoma monitoring, and to evaluate associations between change of morphological tumour characteristics during treatment and changes of cerebral thallium uptake and metabolic ratios. Results and conclusions: - High TI-index, calculated as a ratio comparing tumour uptake to uptake in the contralateral hemisphere, is an indicator of highly malignant astrocytoma. Differentiation between the high-grade astrocytomas, the low-grade astrocytomas, and infectious lesions is only partial, with an overlap of Tl-indexes between these groups. High-grade astrocytomas that do not show contrast enhancement on CT, and astrocytomas with central necrosis and moderate ring-enhancement, tend to be underestimated when evaluated by Tl-index calculation. Tl SPECT is not a reliable method for non-invasive tumour staging among the group of highly malignant astrocytomas. - Quantification of cerebral TI-uptake, defining the volume of viable tumour tissue, is a new method for astrocytoma chemotherapy monitoring. Results suggest that the method provides prognostic information, and information of treatment efficacy, at an earlier stage than CT. - We did not find a higher accuracy of quantitative Tl SPECT than of MR for monitoring purposes and our results indicated that treatment induced MR changes were interrelated with TI-uptake variations. - Multi-voxel H-MRS was difficult to apply for astrocytoma treatment monitoring, due to the anatomical

  14. Brain lesion analysis using three-dimensional SPECT imaging

    International Nuclear Information System (INIS)

    Shibata, Iekado; Onagi, Atsuo; Kuroki, Takao

    1995-01-01

    A three-headed gamma camera (PRISM 3000) is capable to scan the protocol of early dynamic SPECT and to analyze two radioisotopes at the same time. We have framed three-dimensional brain SPECT images for several brain diseases by using the Application Visualization System (AVS). We carried out volume measurements in brain tumors and/or AVMs by applying this methodology. Thallium-201 and/or 123I-IMP were used for brain SPECT imaging. The dynamic scan protocol was changed in accordance with the given disease. The protocol for brain tumors was derived from a preliminary comparative study with thallium-201 and 123I-IMP that had suggested a disparity in the detection of brain tumors and the differentiation between tumor tissue and normal brain. The three-dimension SPECT image represented the brain tumor or AVM in a striking fashion, and the changes with respect to tumor or AVM after radiosurgery or embolization were understood readily. (author)

  15. Correction for patient and organ movement in SPECT: application to exercise thallium-201 cardiac imaging

    International Nuclear Information System (INIS)

    Geckle, W.J.; Frank, T.L.; Links, J.M.; Becker, L.C.

    1988-01-01

    We describe a technique for correction of artifacts in exercise 201 Tl single photon emission computed tomography (SPECT) images arising from abrupt or gradual translational movement of the heart during acquisition. The procedure involves the tracking of the center of the heart in serial projection images using an algorithm which we call diverging squares. Each projection image is then realigned in the x-y plane so that the heart center conforms to the projected position of a fixed point in space. The shifted projections are reconstructed using the normal filtered backprojection algorithm. In validation studies, the motion correction procedure successfully eliminated movement artifacts in a heart phantom. Image quality was also improved in over one-half of 36 exercise thallium patient studies. The corrected images had smoother and more continuous left ventricular walls, greater clarity of the left ventricular cavity, and reduced streak artifacts. Rest injected or redistribution images, however, were often made worse, due to reduced heart to liver activity ratios and poor tracking of the heart center. Analysis of curves of heart position versus projection angle suggests that translation of the heart is common during imaging after exercise, and results from both abrupt patient movements, and a gradual upward shift of the heart. Our motion correction technique appears to represent a promising new approach for elimination of movement artifacts and enhancement of resolution in exercise 201 Tl cardiac SPECT images

  16. A clinical study of thallium-201 SPECT in the diagnostic imaging of oral squamous cell carcinomas

    International Nuclear Information System (INIS)

    Satoh, Hitoshi

    2003-01-01

    Recently the usefulness of thallium 201 chloride (201Tl) as a tumor imaging agent for various tumors has been reported. However, the application of 201Tl SPECT to oral squamous cell carcinomas has not been established. The purpose of this study is to investigate the usefulness of 201Tl SPECT in the assessment of malignancy or in the differential diagnosis of oral squamous cell carcinomas from inflammatory diseases. Thirty-two patients with 33 primary oral squamous cell carcinomas and 4 patients with inflammatory disease were studied. SPECT images were acquired 15 minutes (early image) and 3 hours (delayed image) after the intravenous injection with 74 MBq 201Tl, and then early uptake ratio (ER), delayed uptake ratio (DR), and retention index (RI) were measured. The relations between these parameters and the size, the site, the degree of differentiation and the mode of invasion of the primary tumor were analyzed statistically. 201Tl SPECT correctly identified 32 of the 33 tumors, with 32 patients having oral squamous cell carcinoma, making the positive rate 97%. Significant negative correlation was observed between RI and major or minor axis of tumors; therefore, this study revealed that RI was influenced by the size of a tumor. In comparison with the average value of RI according to histopathological diagnosis, there was statistically significant difference (p=0.011) between carcinomas (0.80±0.16, n=30) and inflammatory diseases (0.58±0.04, n=4); thus, it was supposed that differential diagnosis between them could be possible. About the tumors with the range of minor-axis 20 mm-40 mm for little influence of tumor size to the RI, the tendency to decrease for the RI of well-differentiated group or low-invasive group was seen. For oral squamous cell carcinomas, 201Tl SPECT had a high positive rate. The application was suggested for use in the differential diagnosis between inflammatory disease and carcinomas, where clinical usefulness could be expected. (author)

  17. Comparison of 18F-FDG PET and 201 thallium chloride SPECT in the evaluation of cerebral glioma prior to surgery

    International Nuclear Information System (INIS)

    Poon, A.M.T.; Cher, L.; Berlangieri, S.U.; Fabinyi, G.; Tochon-Danguy, H.; Chan, J.G.; Scott, A.M.

    2000-01-01

    Full text: The purpose of the study was to compare the accuracy of 18 F-FDG PET and 201 Tl SPECT in detecting and grading primary cerebral glioma through comparison to surgical pathology. A total of 33 patients with primary cerebral glioma had 35 18 F-FDG PET/ 201 Tl SPECT scans prior to surgery. Pre-operative 18 F -FDG PET and 201 Tl SPECT studies were reviewed and compared with histologic tumour grade. Radiological comparisons were also performed when pre-operative studies were available. 17/18 patients with glioblastoma multiforme demonstrated hypermetabolic lesions on 18 F-FDG PET scan and increased thallium uptake on SPECT scan. Increased 18 F -FDG and thallium uptake were also demonstrated in patients with anaplastic astrocytoma, gemistocytic astrocytoma, and one biopsy which was difficult to grade because of small biopsy sample and co-existing radiation necrosis. In general, low grade gliomas had reduced 18 F -FDG uptake and normal thallium uptake (6/7, where two patients had tumour with hypermetabolic and hypometabolic regions). MRI correctly identified 4/7 patients with low to intermediate grade glioma. Pilocytic astrocytoma, protoplastic astrocytoma and oligoastrocytoma all demonstrated hypometabolic PET activity and normal thallium uptake. In conclusion, 18 F-FDG PET and 201 Tl SPECT are very sensitive in pre-operative prediction of high grade glioma. In low grade tumour, 201 Tl SPECT appeared to be less useful in the absence of breakdown of the blood brain barrier. MR imaging accurately identified the presence of tumour but was less accurate in determining the grade of tumour. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  18. Thallium imaging in management of post-revascularization patients

    International Nuclear Information System (INIS)

    Alazraki, N.; Krawczynska, E.

    1996-01-01

    The role of myocardial perfusion imaging in the evaluation of post revascularization patients has not been well defined. Published data with special emphasis on the results from the Emory Angioplasty versus Surgery Trial (EAST) indicate that the frequency of adverse cardiac events (death, MI, repeat revascularization) following PTCA or CABG is equal in symptomatic and asymptomatic patients with ischemic thallium defects. Current American Heart Association Guidelines recommend radionuclide studies only in symptomatic patients. Recently reported data support the need for non invasive testing in asymptomatic as well as symptomatic patients at 1 year postrevascularization. Prognostic variables including transient and permanent left ventricular dilatation and thallium lung uptake in addition to stress perfusion defect reversibility on myocardial thallium SPECT scans are important prognostic indicators in post revascularization patients

  19. Does supplementation of contrast MR imaging with thallium-201 brain SPECT improve differentiation between benign and malignant ring-like contrast-enhanced cerebral lesions?

    International Nuclear Information System (INIS)

    Kita, Tamotsu; Hayashi, Katsumi; Yamamoto, Masayoshi; Kawauchi, Toshio; Sakata, Ikuko; Iwasaki, Yoshie; Kosuda, Shigeru

    2007-01-01

    The objective of this study was to determine whether thallium-201 ( 201 Tl) brain single photon emission computed tomography (SPECT) could supplement magnetic resonance (MR) imaging diagnostic information by visual comparison of two separate data sets from patients with ring-like contrast-enhanced cerebral lesions. A combination of MR imaging and 201 Tl brain SPECT sets obtained from 13 patients (10 men, 3 women) ranging in age from 26 years to 86 years (mean 61.0 years) were retrospectively reviewed. A total of 12 patients had a solitary lesion, and the others had multiple lesions. All but two intracranial foci were pathologically confirmed. The final diagnoses were six glioblastomas, two cerebral metastases from lung cancer, and one each of abscess, resolving hematoma, primary central nervous system lymphoma, toxoplasmosis, and radiation necrosis. The two separate image formats (MR images and SPECT) were shown to ten readers with practical experience. All of the MR images for each patient were shown to each reader first. After interpreting them, the readers were shown the SPECT images. Images were scored in terms of how benign or malignant the foci were on a 5-point scale from ''definitely benign'' to ''definitely malignant.'' The improvement in the performance of all ten readers was from 67.7% to 93.8% in mean accuracy (P=0.0028) and from 0.730 to 0.971 in mean Az value (P=0.0069) after they were shown the 201 Tl brain SPECT images. 201 Tl brain SPECT should substantially increase confidence in the diagnosis of intracranial lesions with ring-like contrast enhancement when MR imaging does not permit differentiation between benign and malignant disease. (author)

  20. Quantitation of postexercise lung thallium-201 uptake during single photon emission computed tomography

    International Nuclear Information System (INIS)

    Kahn, J.K.; Carry, M.M.; McGhie, I.; Pippin, J.J.; Akers, M.S.; Corbett, J.R.

    1989-01-01

    To test the hypothesis that analysis of lung thallium uptake measured during single photon emission computed tomography (SPECT) yields supplementary clinical information as reported for planar imaging, quantitative analysis of lung thallium uptake following maximal exercise was performed in 40 clinically normal subjects (Group 1) and 15 angiographically normal subjects (Group 2). Lung thallium uptake was measured from anterior projection images using a ratio of heart-to-lung activities. Seventy subjects with coronary artery disease (CAD) (Group 3) determined by angiography (greater than or equal to 70% luminal stenosis) underwent thallium perfusion SPECT. Thirty-nine percent of these subjects had multivessel and 61% had single vessel CAD. Lung thallium uptake was elevated in 47 of 70 (67%) Group 3 subjects. Group 3 subjects with elevated lung thallium uptake did not differ from Group 3 subjects with normal lung thallium uptake with respect to extent or distribution of coronary artery disease, left ventricular function, or severity of myocardial ischemia as determined by exercise and redistribution thallium SPECT. Thus, the measurement of thallium lung uptake from anterior projection images obtained during SPECT frequently identifies patients with CAD, but it may not provide supplementary information regarding the extent of myocardial ischemia or ventricular dysfunction

  1. Myocardial viability assessment with dynamic low-dose iodine-123-iodophenylpentadecanoic acid metabolic imaging: comparison with myocardial biopsy and reinjection SPECT thallium after myocardial infarction.

    Science.gov (United States)

    Murray, G L; Schad, N C; Magill, H L; Vander Zwaag, R

    1994-04-01

    Aggressive cardiac revascularization requires recognition of stunned and hibernating myocardium, and cost considerations may well govern the technique used. Dynamic low-dose (1 mCi) [123I]iodophenylpentadecanoic acid (IPPA) metabolic imaging is a potential alternative to PET using either 18FDG or 15O-water. Resting IPPA images were obtained from patients with severe ischemic cardiomyopathy, and transmural myocardial biopsies were obtained during coronary bypass surgery to confirm viability. Thirty-nine of 43 (91%) biopsies confirmed the results of the IPPA images with a sensitivity for viability of 33/36 (92%) and a specificity of 6/7 (86%). Postoperatively, wall motion improved in 80% of IPPA-viable, dysfunctional segments. Furthermore, when compared to reinjection thallium (SPECT-TI) scans after myocardial infarction, IPPA-SPECT-TI concordance occurred in 27/35 (77%) (K = 0.536, p = 0.0003). Similar to PET, IPPA demonstrated more viability than SPECT-TI, 26/35 (74%) versus 18/35 (51%) (p = 0.047). Metabolic IPPA cardiac viability imaging is a safe, inexpensive technique that may be a useful alternative to PET.

  2. Differential diagnosis in patients with ring-like thallium-201 uptake in brain SPECT

    International Nuclear Information System (INIS)

    Kinuya, Keiko; Ohashi, Masahiro; Itoh, Syotaro

    2002-01-01

    This study was performed to investigate lesions with ring-like thallium-201 ( 201 Tl) uptake and to determine whether SPECT provides any information in differential diagnosis. A total of 244 201 Tl SPECT images were reviewed. In each study, early (15 min postinjection) and late (3 hr) brain SPECT images were obtained with 111 MBq of 201 Tl. The early uptake ratio (ER; lesion to normal brain average count ratio) and the late uptake ratio (LR) and the L/E ratio (ratio of LR to ER) were calculated. Ring-like uptake was observed in pre-therapeutic 26 SPECT images, including ten glioblastoma multiformes (ER, 3.45±0.64; LR, 2.74±0.54; L/E ratio 0.80±0.13), five meningiomas (6.48±2.34; 4.41±1.41; 0.72±0.19), four metastatic lung cancers (3.47±1.23; 2.40±0.98; 0.70±0.14), four brain abscesses (2.48±1.06; 1.59±0.30; 0.78±0.15), one invasive lesion of squamous cell carcinoma from the ethmoid sinus (1.54; 1.52; 0.99), one medulloblastoma (3.53; 3.52; 1.00) and one hematoma (3.32; 2.36; 0.71). The ER of meningioma was significantly higher than those of glioblastoma multiforme (p 201 Tl SPECT has still difficulty in differentiating abscess from brain tumor. (author)

  3. Cerebral blood flow imaging with thallium-201 diethyldithiocarbamate SPECT

    NARCIS (Netherlands)

    van Royen, E. A.; de Bruïne, J. F.; Hill, T. C.; Vyth, A.; Limburg, M.; Byse, B. L.; O'Leary, D. H.; de Jong, J. M.; Hijdra, A.; van der Schoot, J. B.

    1987-01-01

    Thallium-201 diethyldithiocarbamate ([201TI]DDC) was studied in humans as an agent for cerebral blood flow imaging. Brain uptake proved to be complete 90 sec after injection with no appreciable washout or redistribution for hours. Intracarotid injection suggested an almost 100% extraction during the

  4. Usefulness of isoproterenol stress thallium-201 myocardial single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Watanabe, Shigeyuki; Ajisaka, Ryuichi; Masuoka, Takeshi

    1990-01-01

    Twenty patients complaining of chest pain were referred for isoproterenol stress thallium-201 myocardial single photon emission computed tomography (ISO-SPECT). The findings were compared with those obtained from isoproterenol stress ECG testing (ISO-ECG) and exercise SPECT (EX-SPECT). Isoproterenol was iv injected in a dose of 0.02 μg/kg/min. The amount was continuously increased until limited by chest pain, ST depression, and/or determined heart rate criteria. The patients were scanned immediately and three hours after giving isoproterenol. Transient hypoperfusion was regarded as myocardial ischemia. Washout rate, obtained from circumferential profile analysis on the short axis SPECT images, was expressed by Bull's eye display. Fifteen patients with angiographically significant stenosis of 75% or greater were diagnosed as having coronary artery disease (CAD). The other five patients had normal coronary artery (NC). In diagnosing CAD, ISO-ECG and ISO-SPECT had a sensitivity of 80% and 92%, respectively. Because the NC group had negative findings for redistribution on ISO-SPECT, the specificy of ISO-SPECT seemed to be high. For multi-vessel disease, redistribution on ISO-SPECT tended to underestimate coronary lesions. The underestimation was, however, corrected by calculating washout rate. For evaluable 11 patients undergoing concurrent EX-SPECT, ISP-SPECT was equivalent or superior to EX-SPECT in diagnostic sensitivity. None of the patients had severe side effects of isoproterenol, except for some having arrhythmia. The results indicated that ISO-SPECT is a safe, high sensitive diagnostic approach that is comparable to Ex-SPECT. (N.K.)

  5. {sup 201}Thallium SPECT, accuracy in astrocytoma diagnosis and treatment evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kaellen, K

    1999-10-01

    The aims of the studies included in this thesis were: - to investigate the reliability of {sup 201}Thallium single photon emission computed tomography. Tl SPECT for preoperative diagnosis and histological staging of malignant astrocytomas in comparison with CT; - to develop a method for quantification of cerebral thallium uptake, and to evaluate the quantitative measurement in comparison with CT, for astrocytoma treatment follow-up purposes; - to compare quantitative Tl SPECT and proton magnetic resonance spectroscopy (H-MRS) with conventional MR imagingfor astrocytoma monitoring, and to evaluate associations between change of morphological tumour characteristics during treatment and changes of cerebral thallium uptake and metabolic ratios. Results and conclusions: - High TI-index, calculated as a ratio comparing tumour uptake to uptake in the contralateral hemisphere, is an indicator of highly malignant astrocytoma. Differentiation between the high-grade astrocytomas, the low-grade astrocytomas, and infectious lesions is only partial, with an overlap of Tl-indexes between these groups. High-grade astrocytomas that do not show contrast enhancement on CT, and astrocytomas with central necrosis and moderate ring-enhancement, tend to be underestimated when evaluated by Tl-index calculation. Tl SPECT is not a reliable method for non-invasive tumour staging among the group of highly malignant astrocytomas. - Quantification of cerebral TI-uptake, defining the volume of viable tumour tissue, is a new method for astrocytoma chemotherapy monitoring. Results suggest that the method provides prognostic information, and information of treatment efficacy, at an earlier stage than CT. - We did not find a higher accuracy of quantitative Tl SPECT than of MR for monitoring purposes and our results indicated that treatment induced MR changes were interrelated with TI-uptake variations. - Multi-voxel H-MRS was difficult to apply for astrocytoma treatment monitoring, due to the

  6. Prone versus supine thallium myocardial SPECT: A method to decrease artifactual inferior wall defects

    International Nuclear Information System (INIS)

    Segall, G.M.; Davis, M.J.

    1989-01-01

    Artifactual inferior wall defects as a result of diaphragmatic attenuation of activity are a frequent source of error in thallium myocardial single photon emission computed tomography (SPECT) studies. Thirty-four patients and 11 clinically normal volunteers were studied prospectively to see if specificity of inferior wall defects for right coronary artery disease could be improved by scanning patients prone versus supine. All individuals were scanned both prone and supine, in random order, following symptom limited treadmill exercise. Images were acquired at 3 degrees steps, 25 sec per frame, in a 180 degrees elliptical orbit always beginning in the 45 degrees right anterior oblique position relative to the patient. Polar maps generated from the short axis slices were used to calculate the average regional activity. The prone studies showed consistently higher inferior wall activity compared to the supine studies on both the exercise (182 +/- 22 vs. 160 +/- 23, p less than or equal to 0.001) and 4-hr delay studies (183 +/- 20 vs. 175 +/- 21, p less than or equal to 0.001). Prone imaging resulted in a significantly higher specificity for RCA disease compared to supine imaging (90% vs. 66%, p less than 0.05) with an improvement in accuracy from 71% to 82%. Sensitivity, specificity, and accuracy for left anterior descending and left circumflex artery disease were not significantly affected by patient position during imaging. All patients having SPECT thallium myocardial perfusion studies should be imaged prone to minimize artifactual inferior wall defects and improve accuracy

  7. Quantification of reversible perfusion abnormality using exercise-stress thallium SPECT before and after coronary revascularization

    International Nuclear Information System (INIS)

    Nagao, Kazuhiko; Nakata, Tomoaki; Tsuchihashi, Kazufumi

    1994-01-01

    Reversible myocardial perfusion abnormality was quantified by bull's eye and unfolded surface mapping methods in exercise thallium SPECT before and after coronary revascularization in 47 patients with angina pectoris, including 34 patients with previous myocardial infarction (PMI) and 13 with effort angina (AP). There was no difference in the incidence or extent of myocardial ischemia between the 2 groups before revascularization. However, the ischemic scores were significantly smaller in PMI group preoperatively than the reductions of the ischemic scores after revascularization. The ischemic scores, preoperatively estimated reversible perfusion abnormality was 32%, 69% and 48% of the improvement of the ischemic score (extent score, severity score, and ischemic area, respectively). Using the 3 ischemic scores, the improvement of perfusion abnormality was well predicted in 70-89% of AP patients but 35-57% of PMI patients. Thus, quantitative analysis in stress thallium SPECT is useful for detecting myocardial ischemia and evaluating the effect of coronary revascularization. However, about a half of myocardial viability was underestimated in one third of PMI patients by the conventional exercise-stress thallium SPECT study. (author)

  8. Thallium brain SPECT and MRI correlation in the evaluation of tumour recurrence versus radiation necrosis

    International Nuclear Information System (INIS)

    Robins, P.D.; Mahoney, D.S.; Mullan, B.P.

    2000-01-01

    Full text: This study compares different methods of determining thallium tumour uptake indices. Correlation with MR was performed to evaluate features that may affect the thallium index (TI) and to improve specificity for differentiation of recurrent tumor from radiation necrosis. 23 patients who had received radiotherapy for a brain neoplasm were included. The TI was determined using three different methods including large and small regions-of-interest (ROI). The concordance between the thallium SPECT and MRI was assessed. The effect of central necrosis on the different thallium indices derived was evaluated. 18 patients were determined to have recurrent tumor and five had inactive disease. The optimal TI cut-off values was statistically delivered and sensitivity and specificity was 78-94% and 80% respectively for cut-off values between 2.0 and 2.6 depending on the method used to calculate the TI. When compared with MRI, the majority of SPECT abnormalities correlated well with location and degree of uptake and enhancement. Seven cases showed central necrosis and the degree of necrosis had less effect on the TI when a small ROI was used in these cases. In conclusion thallium brain SPECT is a sensitive technique for detecting recurrent tumour. When performing semi-quantitative assessment of thallium uptake, a smaller ROI over the most intense area of uptake will reduce the underestimation of the TI in the presence of necrosis and a Tl cut-off value of 2.6 gave optimal accuracy using this method. Correlation with MRI aids in localization, particularly where there is anatomic distortion and enables more accurate analysis of these lesions by avoiding areas of necrosis. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  9. Qualification of viable myocardium in the infarcted area by dual isotope In-111 antimyosin Fab and thallium SPECT imaging

    International Nuclear Information System (INIS)

    Mitani, Isao; Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kouhei; Kumita, Shin-ichirou; Oka, Hisatsugu; Haze, Kazuo; Nonoki, Hiroshi

    1991-01-01

    Dual isotope In-111 antimyosin (AM) Fab and thallium SPECT imaging was performed in 33 patients with acute myocardial infarction. Thirteen patients in whom coronary reperfusion could successfully be achieved at the acute stage had higher AM uptake parameters, including AM SCORE, AM AREA, and SCORE/AREA, and the maximum CPK value than the other 20 patients. Left ventricular ejection fraction had a stronger correlation with AM AREA than with AM SCORE (0.601 vs 0.387). Overlap phenomenon was seen in 18 patients (55%). In 28 patients followed up with coronary arteriography, 10 patients had a ≥75% coronary stenosis in the infarct-related vessel; 5 of these 10 had ischemic events. In 13 patients undergoing subsequent thallium-201 scintigraphy at rest, 6 (46%) were found to have marked reduction of perfusion defect (the improved group). Regarding thallium-201 DEFECT SCORE early after the onset of myocardial infarction, there was no significant difference between the aforementioned improved group (15±5) and the non-improved group (17±7). However, In-111 AM uptake in the infarct area was smaller in the improved group than the non-improved group, which means that the infarcted area did not become necrotic early after the onset of myocardial infarction. This may have been responsible for the improvement of perfusion defect in cases of myocardial infarction. (N.K.)

  10. Dipyridamole thallium imaging

    International Nuclear Information System (INIS)

    Beer, S.G.; Heo, J.; Iskandrian, A.S.

    1991-01-01

    Dipyridamole cardiac imaging is a useful alternative to exercise stress testing in the evaluation of patients with ischemic heart disease. Intravenous dipyridamole has been approved recently for clinical use. Oral dipyridamole is widely available. The hemodynamic effects of dipyridamole include an increase in coronary blood flow in excess of the increase in myocardial oxygen consumption and cardiac output. The quality of the thallium images is better or similar to that of exercise thallium images. The optimal dose of intravenous dipyridamole is 0.56 mg/kg and the optimal oral dose is 300-375 mg, although higher doses may be necessary in some patients. The sensitivity and specificity of dipyridamole-thallium imaging, whether intravenous or oral, have been shown in a number of studies to be quite adequate and comparable to that achieved during exercise thallium imaging. Dipyridamole-thallium imaging has also been useful in identifying high-risk patients undergoing major elective vascular surgery. The relative merits of dipyridamole imaging versus exercise testing after acute myocardial infarction require further studies.83 references

  11. Thallium-201 single photon emission computed tomography (SPECT) in patients with Duchenne's progressive muscular dystrophy. A histopathologic correlation study

    International Nuclear Information System (INIS)

    Nishimura, Toru; Yanagisawa, Atsuo; Sakata, Konomi; Shimoyama, Katsuya; Yoshino, Hideaki; Ishikawa, Kyozo; Sakata, Hitomi; Ishihara, Tadayuki

    2001-01-01

    The pathomorphologic mechanism responsible for abnormal perfusion imaging during thallium-201 myocardial single photon emission computed tomography ( 201 Tl-SPECT) in patients with Duchenne's progressive muscular dystrophy (DMD) was investigated. Hearts from 7 patients with DMD were evaluated histopathologically at autopsy and the results correlated with findings on initial and delayed resting 201 Tl-SPECT images. The location of segments with perfusion defects correlated with the histopathologically abnormal segments in the hearts. Both the extent and degree of myocardial fibrosis were severe, especially in the posterolateral segment of the left ventricle. Severe transmural fibrosis and severe fatty infiltration were common in segments with perfusion defects. In areas of redistribution, the degree of fibrosis appeared to be greater than in areas of normal perfusion; and intermuscular edema was prominent. Thus, the degree and extent of perfusion defects detected by 201 Tl-SPECT were compatible with the histopathology. The presence of the redistribution phenomenon may indicate ongoing fibrosis. Initial and delayed resting 201 Tl-SPECT images can predict the site and progress of myocardial degeneration in patients with DMD. (author)

  12. Studies about the stress transaxial myocardium tomography with thallium -201

    International Nuclear Information System (INIS)

    Rocha Pantoja, M. da.

    1987-01-01

    Since the time of earliest applications of SPECT technology to Thallium-201 myocardial perfusion imaging, there has been no agreement as to what constitutes the best procedures to follow in order to achieve the theoretical advantages of SPECT to diagnose coronary artery disease. The purpose of these studies are to show the results of experimental and clinical investigations, that, have helped to resolve most of some controversies. Myocardial perfusion SPECT with Thallium-201 is clinically useful procedure that is readily applicable for routine clinical application provided correct techniques are utilized. (author)

  13. Assessment of myocardial viability by dynamic tomographic iodine 123 iodophenylpentadecanoic acid imaging: comparison with rest-redistribution thallium 201 imaging.

    Science.gov (United States)

    Iskandrian, A S; Powers, J; Cave, V; Wasserleben, V; Cassell, D; Heo, J

    1995-01-01

    This study examined the ability of dynamic 123I-labeled iodophenylpentadecanoic acid (IPPA) imaging to detect myocardial viability in patients with left ventricular (LV) dysfunction caused by coronary artery disease. Serial 180-degree single-photon emission computed tomographic (SPECT) images (five sets, 8 minutes each) were obtained starting 4 minutes after injection of 2 to 6 mCi 123I at rest in 21 patients with LV dysfunction (ejection fraction [EF] 34% +/- 11%). The segmental uptake was compared with that of rest-redistribution 201Tl images (20 segments/study). The number of perfusion defects (reversible and fixed) was similar by IPPA and thallium (11 +/- 5 vs 10 +/- 5 segments/patient; difference not significant). There was agreement between IPPA and thallium for presence or absence (kappa = 0.78 +/- 0.03) and nature (reversible, mild fixed, or severe fixed) of perfusion defects (kappa = 0.54 +/- 0.04). However, there were more reversible IPPA defects than reversible thallium defects (7 +/- 4 vs 3 +/- 4 segments/patient; p = 0.001). In 14 patients the EF (by gated pool imaging) improved after coronary revascularization from 33% +/- 11% to 39% +/- 12% (p = 0.002). The number of reversible IPPA defects was greater in the seven patients who had improvement in EF than in the patients without such improvement (10 +/- 4 vs 5 +/- 4 segments/patient; p = 0.075). 123I-labeled IPPA SPECT imaging is a promising new technique for assessment of viability. Reversible defects predict recovery of LV dysfunction after coronary revascularization.

  14. Intravenous dipyridamole thallium-201 SPECT imaging in patients with left bundle branch block

    International Nuclear Information System (INIS)

    Rockett, J.F.; Wood, W.C.; Moinuddin, M.; Loveless, V.; Parrish, B.

    1990-01-01

    Tl-201 exercise imaging in patients with left bundle branch block (LBBB) has proven to be indeterminate for significant left anterior descending (LAD) coronary artery stenosis because of the presence of immediate septal perfusion defects with redistribution on delayed images in almost all cases. Tl-201 redistribution occurs regardless of the presence or absence of LAD stenosis. Nineteen patients having LBBB were evaluated with dipyridamole Tl-201 SPECT. Fourteen of these subjects had normal dipyridamole Tl-201 SPECT imaging. Three patients had normal coronary angiograms. None of the remaining 11 patients with normal dipyridamole Tl-201 SPECT images was found to have clinical coronary artery disease in a 5-11 month follow-up period. Five patients had abnormal septal perfusion. Four underwent coronary angiography. One had a significant LAD stenosis. The single patient with septal redistribution who refused to undergo coronary angiography died shortly thereafter of clinical coronary artery disease. This preliminary work suggests that dipyridamole Tl-201 SPECT may be more useful for excluding LAD stenosis in patients with LBBB than Tl-201 exercise imaging

  15. Occult primary tumors of the head and neck: accuracy of thallium 201 single-photon emission computed tomography and computed tomography and/or magnetic resonance imaging

    NARCIS (Netherlands)

    van Veen, S. A.; Balm, A. J.; Valdés Olmos, R. A.; Hoefnagel, C. A.; Hilgers, F. J.; Tan, I. B.; Pameijer, F. A.

    2001-01-01

    To determine the accuracy of thallium 201 single-photon emission computed tomography (thallium SPECT) and computed tomography and/or magnetic resonance imaging (CT/MRI) in the detection of occult primary tumors of the head and neck. Study of diagnostic tests. National Cancer Institute, Amsterdam,

  16. Differential diagnosis in patients with ring-like thallium-201 uptake in brain SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kinuya, Keiko; Ohashi, Masahiro; Itoh, Syotaro [Tonami General Hospital, Toyama (Japan)] (and others)

    2002-09-01

    This study was performed to investigate lesions with ring-like thallium-201 ({sup 201}Tl) uptake and to determine whether SPECT provides any information in differential diagnosis. A total of 244 {sup 201}Tl SPECT images were reviewed. In each study, early (15 min postinjection) and late (3 hr) brain SPECT images were obtained with 111 MBq of {sup 201}Tl. The early uptake ratio (ER; lesion to normal brain average count ratio) and the late uptake ratio (LR) and the L/E ratio (ratio of LR to ER) were calculated. Ring-like uptake was observed in pre-therapeutic 26 SPECT images, including ten glioblastoma multiformes (ER, 3.45{+-}0.64; LR, 2.74{+-}0.54; L/E ratio 0.80{+-}0.13), five meningiomas (6.48{+-}2.34; 4.41{+-}1.41; 0.72{+-}0.19), four metastatic lung cancers (3.47{+-}1.23; 2.40{+-}0.98; 0.70{+-}0.14), four brain abscesses (2.48{+-}1.06; 1.59{+-}0.30; 0.78{+-}0.15), one invasive lesion of squamous cell carcinoma from the ethmoid sinus (1.54; 1.52; 0.99), one medulloblastoma (3.53; 3.52; 1.00) and one hematoma (3.32; 2.36; 0.71). The ER of meningioma was significantly higher than those of glioblastoma multiforme (p<0.0005), metastatic lung cancer (p<0.005) and brain abscess (p<0.0005). There were no significant differences among these three entities. The LR of meningioma was significantly higher than those of glioblastoma multiforme (p<0.005), metastatic lung cancer (p<0.005) and brain abscess (p<0.0001). The LR of brain abscess was significantly lower than that of glioblastoma multiforme (p<0.05). The L/E ratio could not differentiate these four entities. High ER and high LR in a lesion with ring-like uptake is likely an indicator of meningioma. The LR of brain abscess was significantly lower than that of glioblastoma multiforme, but {sup 201}Tl SPECT has still difficulty in differentiating abscess from brain tumor. (author)

  17. Comparison of exercise radionuclide angiography with thallium SPECT imaging for detection of significant narrowing of the left circumflex coronary artery

    International Nuclear Information System (INIS)

    Dilsizian, V.; Perrone-Filardi, P.; Cannon, R.O. III; Freedman, N.M.; Bacharach, S.L.; Bonow, R.O.

    1991-01-01

    Although quantitation of exercise thallium tomograms has enhanced the noninvasive diagnosis and localization of coronary artery disease, the detection of stenosis of the left circumflex coronary artery remains suboptimal. Because posterolateral regional wall motion during exercise is well assessed by radionuclide angiography, this study determined whether regional dysfunction of the posterolateral wall during exercise radionuclide angiography is more sensitive in identifying left circumflex disease than thallium perfusion abnormalities assessed by single-photon emission computed tomography (SPECT). One hundred ten consecutive patients with CAD were studied, of whom 70 had a significant stenosis of the left circumflex coronary artery or a major obtuse marginal branch. Both regional function and segmental thallium activity of the posterolateral wall were assessed using visual and quantitative analysis. Left ventricular regional function was assessed objectively by dividing the left ventricular region of interest into 20 sectors; the 8 sectors corresponding to the posterolateral free wall were used to assess function in the left circumflex artery distribution. Similarly, using circumferential profile analysis of short-axis thallium tomograms, left ventricular myocardial activity was subdivided into 64 sectors; the 16 sectors corresponding to the posterolateral region were used to assess thallium perfusion abnormalities in the left circumflex artery territory. Qualitative posterolateral wall motion analysis detected 76% of patients with left circumflex coronary artery stenosis, with a specificity of 83%, compared with only 44% by qualitative thallium tomography (p less than 0.001) and a specificity of 92%

  18. Thallium-201 single photon emission computed tomography (SPECT) in patients with Duchenne's progressive muscular dystrophy. A histopathologic correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Toru; Yanagisawa, Atsuo; Sakata, Konomi; Shimoyama, Katsuya; Yoshino, Hideaki; Ishikawa, Kyozo [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine; Sakata, Hitomi; Ishihara, Tadayuki

    2001-02-01

    The pathomorphologic mechanism responsible for abnormal perfusion imaging during thallium-201 myocardial single photon emission computed tomography ({sup 201}Tl-SPECT) in patients with Duchenne's progressive muscular dystrophy (DMD) was investigated. Hearts from 7 patients with DMD were evaluated histopathologically at autopsy and the results correlated with findings on initial and delayed resting {sup 201}Tl-SPECT images. The location of segments with perfusion defects correlated with the histopathologically abnormal segments in the hearts. Both the extent and degree of myocardial fibrosis were severe, especially in the posterolateral segment of the left ventricle. Severe transmural fibrosis and severe fatty infiltration were common in segments with perfusion defects. In areas of redistribution, the degree of fibrosis appeared to be greater than in areas of normal perfusion; and intermuscular edema was prominent. Thus, the degree and extent of perfusion defects detected by {sup 201}Tl-SPECT were compatible with the histopathology. The presence of the redistribution phenomenon may indicate ongoing fibrosis. Initial and delayed resting {sup 201}Tl-SPECT images can predict the site and progress of myocardial degeneration in patients with DMD. (author)

  19. Noninvasive quantification of myocardial perfusion heterogeneity by Markovian analysis in SPECT nuclear imaging

    International Nuclear Information System (INIS)

    Pons, G.

    2011-01-01

    Cardiovascular diseases are the leading cause of mortality worldwide, and third of these deaths are caused by coronary artery disease and rupture of vulnerable atherosclerotic plaques. The heterogeneous alteration of the coronary microcirculation is an early phenomenon associated with many cardiovascular risk factors that can strongly predict the subsequent development of coronary artery disease, and lead to the appearance of myocardial perfusion heterogeneity. Nuclear medicine allows the study of myocardial perfusion in clinical routine through scintigraphic scans performed after injection of a radioactive tracer of coronary blood flow. Analysis of scintigraphic perfusion images currently allows the detection of myocardial ischemia, but the ability of the technique to measure the perfusion heterogeneity in apparently normally perfused areas is unknown. The first part of this thesis focuses on a retrospective clinical study to determine the feasibility of myocardial perfusion heterogeneity quantification measured by Thallium-201 single photon emission computed tomography (SPECT) in diabetic patients compared with healthy subjects. The clinical study has demonstrated the ability of routine thallium-201 SPECT imaging to quantify greater myocardial perfusion heterogeneity in diabetic patients compared with normal subjects. The second part of this thesis tests the hypothesis that the myocardial perfusion heterogeneity could be quantified in small animal SPECT imaging by Thallium-201 and/or Technetium-99m-MIBI in an experimental study using two animal models of diabetes, and is correlated with histological changes. The lack of difference in myocardial perfusion heterogeneity between control and diabetic animals suggests that animal models are poorly suited, or that the technology currently available does not seem satisfactory to obtain similar results as the clinical study. (author)

  20. Identification of viable myocardium in patients with chronic coronary artery disease and left ventricular dysfunction. Comparison of thallium scintigraphy with reinjection and PET imaging with 18F-fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Bonow, R.O.; Dilsizian, V.; Cuocolo, A.; Bacharach, S.L.

    1991-01-01

    In patients with chronic coronary artery disease and left ventricular dysfunction, the distinction between ventricular dysfunction arising from myocardial fibrosis and ischemic, but viable, myocardium has important clinical implications. By positron emission tomography (PET), enhanced fluorine-18-labeled fluorodeoxyglucose (FDG) uptake in myocardial segments with impaired function and reduced blood flow is evidence of myocardial viability. Reinjection of thallium-201 at rest immediately after stress-redistribution imaging may also provide evidence of myocardial viability by demonstrating thallium uptake in regions with apparently irreversible defects. To compare these two methods, we studied 16 patients with chronic coronary artery disease and left ventricular dysfunction, all of whom had irreversible defects on standard exercise-redistribution thallium single-photon emission computed tomography (SPECT) imaging. Thallium was reinjected immediately after the redistribution study, and SPECT images were reacquired. The patients also underwent PET imaging with FDG and oxygen-15-labeled water. A total of 432 myocardial segments were analyzed from comparable transaxial tomograms, of which 166 (38%) had irreversible thallium defects on redistribution images before reinjection. FDG uptake was demonstrated in 121 (73%) of these irreversible defects. Irreversible defects were then subgrouped according to the degree of thallium activity, relative to peak activity in normal regions. Irreversible defects with only mild (60-85% of peak activity) or moderate (50-59% of peak) reduction in thallium activity were considered viable on the basis of FDG uptake in 91% and 84% of these segments, respectively. In contrast, in irreversible defects with severe reduction in thallium activity (less than 50% of peak), FDG uptake was present in 51% of segments

  1. Comparison of conventional and cadmium-zinc-telluride single-photon emission computed tomography for analysis of thallium-201 myocardial perfusion imaging: an exploratory study in normal databases for different ethnicities.

    Science.gov (United States)

    Ishihara, Masaru; Onoguchi, Masahisa; Taniguchi, Yasuyo; Shibutani, Takayuki

    2017-12-01

    The aim of this study was to clarify the differences in thallium-201-chloride (thallium-201) myocardial perfusion imaging (MPI) scans evaluated by conventional anger-type single-photon emission computed tomography (conventional SPECT) versus cadmium-zinc-telluride SPECT (CZT SPECT) imaging in normal databases for different ethnic groups. MPI scans from 81 consecutive Japanese patients were examined using conventional SPECT and CZT SPECT and analyzed with the pre-installed quantitative perfusion SPECT (QPS) software. We compared the summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) for the two SPECT devices. For a normal MPI reference, we usually use Japanese databases for MPI created by the Japanese Society of Nuclear Medicine, which can be used with conventional SPECT but not with CZT SPECT. In this study, we used new Japanese normal databases constructed in our institution to compare conventional and CZT SPECT. Compared with conventional SPECT, CZT SPECT showed lower SSS (p < 0.001), SRS (p = 0.001), and SDS (p = 0.189) using the pre-installed SPECT database. In contrast, CZT SPECT showed no significant difference from conventional SPECT in QPS analysis using the normal databases from our institution. Myocardial perfusion analyses by CZT SPECT should be evaluated using normal databases based on the ethnic group being evaluated.

  2. Effects of cross talk on dual energy SPECT imaging between 123I-BMIPP and 201Tl

    International Nuclear Information System (INIS)

    Morita, Masato; Narita, Hitoshi; Yamamoto, Juro; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru

    1994-01-01

    The study was undertaken to determine how much cross talk influences the visual assessment of dual energy single photon emission computed tomographic (SPECT) images with iodine 123 beta-methyl-p-iodophenylpentadecanoic acid (I-123 BMIPP) and thallium-201 in 15 patients with acute myocardial infarction. After single SPECT with I-123 BMIPP was undertaken, simultaneous dual SPECT with I-123 BMIPP and Tl-201 were undertaken in all patients. Three patients also underwent single SPECT with Tl-201. I-123 BMIPP and Tl-201 uptake was graded in four-score for the comparison between single and dual SPECT images. There was good correlation between dual energy SPECT and both single I-123 BMIPP SPECT (pS=0.97) and single Tl-201 SPECT (pS=0.59). Uptake scores were increased on dual energy SPECT, compared with single I-123 SPECT (8 out of 132 segments) and single Tl-201 SPECT (12 out of 36 segments). Overall, there was a comparatively well correlation between single SEPCT with either I-123 BMIPP or Tl-201 and dual energy SPECT images. However, one tracer uptake sometimes increased in the other tracer defect areas. This was noticeable when I-123 BMIPP exerted an effect on Tl-201. (N.K.)

  3. Assessment of olfactory nerve by SPECT-MRI image with nasal thallium-201 administration in patients with olfactory impairments in comparison to healthy volunteers.

    Directory of Open Access Journals (Sweden)

    Hideaki Shiga

    Full Text Available PURPOSE: The aim of this study was to assess whether migration of thallium-201 ((201Tl to the olfactory bulb were reduced in patients with olfactory impairments in comparison to healthy volunteers after nasal administration of (201Tl. PROCEDURES: 10 healthy volunteers and 21 patients enrolled in the study (19 males and 12 females; 26-71 years old. The causes of olfactory dysfunction in the patients were head trauma (n = 7, upper respiratory tract infection (n = 7, and chronic rhinosinusitis (n = 7. (201TlCl was administered unilaterally to the olfactory cleft, and SPECT-CT was conducted 24 h later. Separate MRI images were merged with the SPECT images. (201Tl olfactory migration was also correlated with the volume of the olfactory bulb determined from MRI images, as well as with odor recognition thresholds measured by using T&T olfactometry. RESULTS: Nasal (201Tl migration to the olfactory bulb was significantly lower in the olfactory-impaired patients than in healthy volunteers. The migration of (201Tl to the olfactory bulb was significantly correlated with odor recognition thresholds obtained with T&T olfactometry and correlated with the volume of the olfactory bulb determined from MRI images when all subjects were included. CONCLUSIONS: Assessment of the (201Tl migration to the olfactory bulb was the new method for the evaluation of the olfactory nerve connectivity in patients with impaired olfaction.

  4. The significance of resting thallium-201 delayed SPECT for assessing viability of infarcted regions

    International Nuclear Information System (INIS)

    Mori, Takao; Yamabe, Hiroshi; Yoshida, Hiroyuki; Maeda, Kazumi; Fukuzaki, Hisashi

    1991-01-01

    Thirty-eight patients with old myocardial infarction (OMI) and 35 patients with effort angina pectoris (EAP) underwent resting thallium-201 (Tl) SPECT one week after exercise (Ex) Tl SPECT. On the basis of both resting and Ex Tl SPECT scans, OMI patients were divided into 3 groups: those who had Tl redistribution (RD) on Ex images and the same perfusion defect (PD) on both resting and Ex delayed images (n=12, Group 1); those who had a lower PD on resting delayed images than Ex delayed images (n=15, Group 2); and those who had no Tl RD on Ex images in spite of the same PD on both resting and EX delayed images (n=11, Group 3). EAP patients were divided into Group 1 (n=18) in whom no PD was seen on Ex delayed image and Group 2 (n=17) in whom PD was not seen on Ex delayed images either, but seen on resting delayed images. EX images showed higher pulmonary artery wedge pressure in Group 2 than Group 1 of both OMI and EAP patients (27±7 mmHg vs 15±6 mmHg for OMI patients; 22±6 mmHg vs 12±7 mmHg for EAP patients). For PD, Tl uptake rate on Ex initial images was higher in Group 1 than Gorup 2 of both OMI and EAP patients (63±7% vs 55±9% for OMI patients; 72±7% vs 65±9% for EAP patients). Resting delayed images for OMI patients showed the highest Tl uptake rate in Group 1 (78±7%), followed by Group 2 (74±8%) and then Group 3 (41±10%). In the group of OMI patients, the incidence of akinetic or dyskinetic wall motion on left ventriculography was the highest in Group 3 (85.7%), followed by Group 2 (52.2%) and Group 1 (24.3%). OMI patients, as well as EAP patients, had lower PD on resting delayed images than EX delayed images. Thus, severer ischemia may be associated with stress and infarcted areas may not involve viable muscle when Tl PD is decreased on resting delayed images. (N.K.)

  5. Time sequential single photon emission computed tomography studies in brain tumour using thallium-201

    International Nuclear Information System (INIS)

    Ueda, Takashi; Kaji, Yasuhiro; Wakisaka, Shinichiro; Watanabe, Katsushi; Hoshi, Hiroaki; Jinnouchi, Seishi; Futami, Shigemi

    1993-01-01

    Time sequential single photon emission computed tomography (SPECT) studies using thallium-201 were performed in 25 patients with brain tumours to evaluate the kinetics of thallium in the tumour and the biological malignancy grade preoperatively. After acquisition and reconstruction of SPECT data from 1 min post injection to 48 h (1, 2, 3, 4, 5, 6, 7, 8, 9, 10 and 15-20 min, followed by 4-6, 24 and 48 h), the thallium uptake ratio in the tumour versus the homologous contralateral area of the brain was calculated and compared with findings of X-ray CT, magnetic resonance imaging, cerebral angiography and histological investigations. Early uptake of thallium in tumours was related to tumour vascularity and the disruption of the blood-brain barrier. High and rapid uptake and slow reduction of thallium indicated a hypervascular malignant tumour; however, high and rapid uptake but rapid reduction of thallium indicated a hypervascular benign tumour, such as meningioma. Hypovascular and benign tumours tended to show low uptake and slow reduction of thallium. Long-lasting retention or uptake of thallium indicates tumour malignancy. (orig.)

  6. Diagnostic value of thallium-201 myocardial perfusion IQ-SPECT without and with computed tomography-based attenuation correction to predict clinically significant and insignificant fractional flow reserve

    Science.gov (United States)

    Tanaka, Haruki; Takahashi, Teruyuki; Ohashi, Norihiko; Tanaka, Koichi; Okada, Takenori; Kihara, Yasuki

    2017-01-01

    Abstract The aim of this study was to clarify the predictive value of fractional flow reserve (FFR) determined by myocardial perfusion imaging (MPI) using thallium (Tl)-201 IQ-SPECT without and with computed tomography-based attenuation correction (CT-AC) for patients with stable coronary artery disease (CAD). We assessed 212 angiographically identified diseased vessels using adenosine-stress Tl-201 MPI-IQ-SPECT/CT in 84 consecutive, prospectively identified patients with stable CAD. We compared the FFR in 136 of the 212 diseased vessels using visual semiquantitative interpretations of corresponding territories on MPI-IQ-SPECT images without and with CT-AC. FFR inversely correlated most accurately with regional summed difference scores (rSDS) in images without and with CT-AC (r = −0.584 and r = −0.568, respectively, both P system can predict FFR at an optimal cut-off of <0.80, and we propose a novel application of CT-AC to MPI-IQ-SPECT for predicting clinically significant and insignificant FFR even in nonobese patients. PMID:29390486

  7. Effects of cross talk on dual energy SPECT imaging between [sup 123]I-BMIPP and [sup 201]Tl

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Masato; Narita, Hitoshi; Yamamoto, Juro; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru (Hyogo College of Medicine, Nishinomiya (Japan))

    1994-01-01

    The study was undertaken to determine how much cross talk influences the visual assessment of dual energy single photon emission computed tomographic (SPECT) images with iodine 123 beta-methyl-p-iodophenylpentadecanoic acid (I-123 BMIPP) and thallium-201 in 15 patients with acute myocardial infarction. After single SPECT with I-123 BMIPP was undertaken, simultaneous dual SPECT with I-123 BMIPP and Tl-201 were undertaken in all patients. Three patients also underwent single SPECT with Tl-201. I-123 BMIPP and Tl-201 uptake was graded in four-score for the comparison between single and dual SPECT images. There was good correlation between dual energy SPECT and both single I-123 BMIPP SPECT (pS=0.97) and single Tl-201 SPECT (pS=0.59). Uptake scores were increased on dual energy SPECT, compared with single I-123 SPECT (8 out of 132 segments) and single Tl-201 SPECT (12 out of 36 segments). Overall, there was a comparatively well correlation between single SEPCT with either I-123 BMIPP or Tl-201 and dual energy SPECT images. However, one tracer uptake sometimes increased in the other tracer defect areas. This was noticeable when I-123 BMIPP exerted an effect on Tl-201. (N.K.).

  8. A new method for quantification of pulmonary thallium uptake in myocardial SPECT studies

    International Nuclear Information System (INIS)

    Mannting, F.

    1990-01-01

    Quantified pulmonary thallium 201 (Tl) uptake was assessed in 32 normal people and 66 patients with suspected coronary artery disease (CAD) by a new method utilizing SPECT acquisition data. In 26 subjects pulmonary uptake was assessed with both SPECT and planar techniques. Pulmonary/myocardial (PM) ratios for the whole right lung (PM1) and for the upper left lung (PM2) were computed and compared with stress test, coronary angiography, radionuclide angiography (ERNA), and quantified Tl SPECT results. Excellent correlation between pulmonary uptake assessed by planar and SPECT technique was disclosed (r=0.92). The PM ratio (PM1/PM2) sensitivity and specificity in patients with CAD was 88%/92% and 60%/70%, for predicting perfusion abnormalities 90%/87% and 88%/88%, and an inverse correlation to LVEF was found (r=-0.40/r=-0.37, P<0.01). Significant correlations to coronary angiography findings (r=0.54/r=0.49, P<0.001) and to number of vessel territories with abnormal perfusion (r=0.70/r=0.69, P<0.001) were seen. Thus, pulmonary Tl uptake can be assessed in SPECT studies. The new method's discriminative ability seems higher than that of the standard planar technique currently employed. Positive correlations to coronary angiography findings and even stronger ones to perfusion abnormalities were observed. (orig.)

  9. Diagnostic value of thallium-201 myocardial perfusion IQ-SPECT without and with computed tomography-based attenuation correction to predict clinically significant and insignificant fractional flow reserve: A single-center prospective study.

    Science.gov (United States)

    Tanaka, Haruki; Takahashi, Teruyuki; Ohashi, Norihiko; Tanaka, Koichi; Okada, Takenori; Kihara, Yasuki

    2017-12-01

    The aim of this study was to clarify the predictive value of fractional flow reserve (FFR) determined by myocardial perfusion imaging (MPI) using thallium (Tl)-201 IQ-SPECT without and with computed tomography-based attenuation correction (CT-AC) for patients with stable coronary artery disease (CAD).We assessed 212 angiographically identified diseased vessels using adenosine-stress Tl-201 MPI-IQ-SPECT/CT in 84 consecutive, prospectively identified patients with stable CAD. We compared the FFR in 136 of the 212 diseased vessels using visual semiquantitative interpretations of corresponding territories on MPI-IQ-SPECT images without and with CT-AC.FFR inversely correlated most accurately with regional summed difference scores (rSDS) in images without and with CT-AC (r = -0.584 and r = -0.568, respectively, both P system can predict FFR at an optimal cut-off of reserved.

  10. Retention index of thallium-201 single photon emission computerised tomography (SPECT) as an indicator of metastasis in adenocarcinoma of the lung.

    Science.gov (United States)

    Takekawa, H.; Itoh, K.; Abe, S.; Ogura, S.; Isobe, H.; Sukou, N.; Furudate, M.; Kawakami, Y.

    1994-01-01

    We examined the relationship between the retention of thallium-201 (201Tl) on a delayed scan and the metastatic potential of adenocarcinomas of the lung. We studied 43 patients with adenocarcinoma of the lung and divided them into two groups according to the presence or absence of lymph node metastasis. 201Tl single photon emission computerised tomography (SPECT) was conducted twice: 15 min (early scan) and 120 min (delayed scan) after intravenous injection of 3 mCi of 201Tl chloride. We calculated the retention index in order to evaluate the degree of 201Tl retention in the primary tumour. The retention indices were significantly higher in the group that was positive for lymph node metastasis than in the negative group. In adenocarcinomas with high metastatic potential, 201Tl SPECT demonstrated slow washout or increased retention on the delayed scan. The retention index of 201Tl SPECT is a useful indicator of metastatic potential, thereby facilitating the prediction of prognosis, and provides insight into the relationship between 201Tl uptake and malignancy. This is the first report demonstrating a significant relationship between the retention of 201Tl SPECT and lymph node metastasis. Images Figure 1 PMID:8054281

  11. Clinical implications of diffuse slow washout of thallium-201 in exercise stress myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru (Sumitomo Hospital, Osaka (Japan))

    1991-07-01

    Clinical implications of diffuse slow washout of thallium-201 (DSWO) in exercise-redistribution myocardial SPECT were studied. Thallium-201 washout rate was calculated by Bull's-eye method. DSWO was defined as having abnormal thallium-201 washout rate (<30% per 3 hours) in more than two thirds of each coronary artery (CA) area. Of 974 patients whose exercise heart rate exceeded 120/min, 51 (5.2%) showed DSWO and coronary angiography was performed in 43. Twenty-three patients (53%) showed triple vessel disease (3VD), 8 (19%) showed single or double vessel disease (1VD/2VD) and 12 (28%) showed normal CA. Patients with normal CA consisted of 6 patients with hypertrophic cardiomyopathy (HCM), 5 with hypertension (HT) and one with electrocardiographic abnormality only. The cause of DSWO were assessed from the history of effort angina (EA) and congestive heart failure (CHF), delayed fill-in of the perfusion defect and the ratio of lung to heart thallium-201 activity (L/M) at exercise as an indicator of the left ventricular (LV) function. High prevalence of EA (74%), high incidence of scintigraphic delayed fill-in (83%) and normal L/M suggested diffuse LV ischemia as the cause of DSWO in 3VD. On the other hand in patients with 1VD/2VD, LV dysfunction at exercise was considered as the cause of DSWO because of low prevalence of EA (13%) and scintigraphic delayed fill-in (13%)(p<0.01, p<0.005 each vs 3VD), and high L/M (p<0.001 vs 3VD) and high prevalence of CHF (38%, NS). In patients with HCM LV ischemia at small vessel levels was assumed as the cause of DSWO from the high incidence of EA (83%) and delayed fill-in (50%), low L/M and normal CA. In cases of HTLV dysfunction and/or LV ischemia at the small vessel levels were considered as the cause of DSWO. Thus, it was concluded that DSWO is a noteworthy finding in exercise stress myocardial imaging. (author).

  12. Assessment of congenital heart disease by a thallium-201 SPECT study in children

    International Nuclear Information System (INIS)

    Ishii, Iwao; Nakajima, Kenichi; Taki, Junichi; Taniguchi, Mitsuru; Bunko, Hisashi; Tonami, Norihisa; Hisada, Kinichi; Ohno, Takashi

    1993-01-01

    The characteristics of correlation between the right-to-left ventricular systolic pressure ratios (RVp/LVp) and the thallium-201 right-to-left ventricular ( 201 Tl R/L) count ratios was investigated in children with various congenital heart diseases. High-resolution three-headed SPECT system equipped with either parallel-hole or fan-beam collimators was used. In a total of 102 patients, the correlation between RVp/LVp and 201 Tl R/L average count ratios was good in both planar (r=0.89, p=0.0001) and SPECT studies (r=0.80, p=0.0001). Quantitative analysis of myocardial uptake by SPECT demonstrated the characteristic pattern of each disease as well as the differences in the right ventricular overload types. When the linear regression analysis was performed in each heart disease, ventricular septal defect showed most excellent correlation. Complex heart anomalies also showed positive correlation (r=0.51, p=0.05) with RVp/LVp, and it can be used to estimate right ventricular pressure. After surgical treatment of tetralogy of Fallot and pulmonary stenosis, the decrease of 201 Tl R/L count ratio was in accordance with improvement of right ventricular overload. We conclude that 201 Tl SPECT study can be a good indicator for estimation of right ventricular pressure. (author)

  13. Brain SPECT with Tl-201 DDC

    International Nuclear Information System (INIS)

    Bruine, J.F. de.

    1988-01-01

    The development, animal and human experiments and the first clinical results of a new blood flow tracer thallium-201 diethyldithiocarbamate (Tl-201 DDC) are discussed for functional brain imaging with single-photon emission computed tomography (SPECT). 325 refs.; 43 figs.; 22 tabs

  14. Safety and feasibility of thallium-201 myocardial SPECT with intravenous infusion of disodium adenosine triphosphate (ATP) in the diagnosis of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Pai, Moon Sun; Park, Chan H.; Yoon, Seok Nam; Kim, Won; Kim, Han Soo [College of Medicine, Ajou Univ., Suwon (Korea, Republic of)

    1998-08-01

    ATP (adenosine triphosphate) is a potent coronary vasodilator with a rapid onset of action and a very short half-life. Myocardial perfusion scintigraphy with intravenous ATP has not yet bee sufficiently proven in the diagnosis, follow-up, and risk stratification of coronary artery disease. The purpose of this study was to evaluate the safety, feasibility and diagnostic accuracy of pharmacologic stress thallium-102 myocardial SPECT using an intravenous ATP infusion in patients with suspected coronary artery disease. Thallium-201 myocardial SPECT in 319 patients with suspected coronary artery disease were performed after the infusion of ATP (0.08 mg/min for 6 min). The adverse effects were carefully monitored. Coronary angiography was also performed within 3 weeks. Although 76.5% of he patients had some adverse effects, they were transient, mild, and well tolerated. In all patients, the ATP infusion protocol was completed and only 2 patients required aminophylline. The adverse effects were dyspnea in 63%, headache in 31%, flushing in 21%, chest pain in 14% and abdominal discomfort in 5% of the patients. The sensitivity and specificity were 80% and 90% respectively. Thallium-201 myocardial SPECT after 6 min-infusion of ATP at a rate of 0.08 mg/kg/min is safe and has a diagnostic value in detecting coronary artery disease.

  15. Safety and feasibility of thallium-201 myocardial SPECT with intravenous infusion of disodium adenosine triphosphate (ATP) in the diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Pai, Moon Sun; Park, Chan H.; Yoon, Seok Nam; Kim, Won; Kim, Han Soo

    1998-01-01

    ATP (adenosine triphosphate) is a potent coronary vasodilator with a rapid onset of action and a very short half-life. Myocardial perfusion scintigraphy with intravenous ATP has not yet bee sufficiently proven in the diagnosis, follow-up, and risk stratification of coronary artery disease. The purpose of this study was to evaluate the safety, feasibility and diagnostic accuracy of pharmacologic stress thallium-102 myocardial SPECT using an intravenous ATP infusion in patients with suspected coronary artery disease. Thallium-201 myocardial SPECT in 319 patients with suspected coronary artery disease were performed after the infusion of ATP (0.08 mg/min for 6 min). The adverse effects were carefully monitored. Coronary angiography was also performed within 3 weeks. Although 76.5% of he patients had some adverse effects, they were transient, mild, and well tolerated. In all patients, the ATP infusion protocol was completed and only 2 patients required aminophylline. The adverse effects were dyspnea in 63%, headache in 31%, flushing in 21%, chest pain in 14% and abdominal discomfort in 5% of the patients. The sensitivity and specificity were 80% and 90% respectively. Thallium-201 myocardial SPECT after 6 min-infusion of ATP at a rate of 0.08 mg/kg/min is safe and has a diagnostic value in detecting coronary artery disease

  16. Dipyridamole thallium imaging may not be a reliable screening test for coronary artery disease in patients undergoing vascular surgery

    International Nuclear Information System (INIS)

    Marwick, T.H.; Underwood, D.A.

    1990-01-01

    Dipyridamole thallium imaging has been proposed for cardiac risk stratification in patients undergoing peripheral vascular surgery. The purpose of this study was to define the benefit of this investigation in routine preoperative evaluation of these patients. The outcome of 86 patients undergoing vascular surgery procedures was examined in light of preoperative clinical assessment and dipyridamole SPECT thallium imaging (DST). Fifty-one patients (59%) were considered at high risk on clinical grounds, and 22 patients (26%) had perfusion defects. Ten patients suffered a perioperative coronary event, including unstable angina, myocardial infarction, or cardiac death. Seven of the patients with such events were among the 51 clinically high-risk subjects (14%). Three perioperative events occurred in the group of 19 patients with positive DST images who underwent surgery (16%), but the DST test failed to identify 7 patients who suffered coronary events. The frequency of abnormal thallium imaging was similar to the prevalence of angiographically significant coronary disease reported previously at this center, but considerably less than the rate of abnormal thallium imaging in past studies of vascular surgery patients. The application of the test to a low to moderate risk population is probably responsible for its lower predictive accuracy for coronary events. DST is not an ideal routine noninvasive technique for risk stratification in patients undergoing vascular surgery

  17. Thallium-201 infusion imaging

    International Nuclear Information System (INIS)

    Alazraki, N.; Kralios, A.; Wooten, W.W.

    1988-01-01

    To test the accuracy of Thallium-201 coronary artery infusion imaging of the earth during rapid changes in blood flow through a major coronary artery, the author performed a study in dogs correlating electromagnetic flow probe recordings with 201 Tl scintillation camera acquisitions. Hyperemic vascular response was produced experimentally in a major coronary artery by occlusion and release interventions which altered flow from baseline to zero during occlusion (20 seconds), followed by rapid flow increases approaching three times baseline immediately upon release of the occlusion. Flow returned to the baseline level within 60 seconds following release. Flow was also altered in a controlled fashion by other interventions. Recordings of Thallium uptake in the myocardium were displayed as a time histogram (counts per second squared vs time) which correlated very closely with electromagnetic flow probe recordings of flow (R=o.82-0.97). These experiments demonstrate a high degree of accuracy in Thallium infusion imaging to detect rapid changes in flow through a major coronary artery

  18. Effect of eating on thallium myocardial imaging

    International Nuclear Information System (INIS)

    Wilson, R.A.; Sullivan, P.J.; Okada, R.D.; Boucher, C.A.; Morris, C.; Pohost, G.M.; Strauss, H.W.

    1986-01-01

    To determine if eating between initial and delayed thallium images alters the appearance of the delayed thallium scan, a prospective study was performed; 184 subjects sent for routine thallium imaging were randomized into two groups, those who ate a meal high in carbohydrates between initial and delayed thallium myocardial images (n = 106), and those who fasted (n = 78). The 201 Tl images were interpreted in blinded fashion for global myocardial and pulmonary clearance of 201 Tl myocardial defects. The eating group had a significantly lower incidence of transient myocardial defects compared to the noneating group (7 percent vs 18 percent, respectively; p less than 0.05). The time between initial and delayed images and the incidence of exercise-induced ischemic ST-segment depression or pathologic Q waves on the electrocardiogram were not significantly different between the two groups. These data suggest that eating a high-carbohydrate meal between initial and delayed 201 Tl images causes increased 201 Tl myocardial clearance rates and may alter 201 Tl myocardial redistribution over time

  19. New SPECT and PET Radiopharmaceuticals for Imaging Cardiovascular Disease

    Directory of Open Access Journals (Sweden)

    Oyebola O. Sogbein

    2014-01-01

    Full Text Available Nuclear cardiology has experienced exponential growth within the past four decades with converging capacity to diagnose and influence management of a variety of cardiovascular diseases. Single photon emission computed tomography (SPECT myocardial perfusion imaging (MPI with technetium-99m radiotracers or thallium-201 has dominated the field; however new hardware and software designs that optimize image quality with reduced radiation exposure are fuelling a resurgence of interest at the preclinical and clinical levels to expand beyond MPI. Other imaging modalities including positron emission tomography (PET and magnetic resonance imaging (MRI continue to emerge as powerful players with an expanded capacity to diagnose a variety of cardiac conditions. At the forefront of this resurgence is the development of novel target vectors based on an enhanced understanding of the underlying pathophysiological process in the subcellular domain. Molecular imaging with novel radiopharmaceuticals engineered to target a specific subcellular process has the capacity to improve diagnostic accuracy and deliver enhanced prognostic information to alter management. This paper, while not comprehensive, will review the recent advancements in radiotracer development for SPECT and PET MPI, autonomic dysfunction, apoptosis, atherosclerotic plaques, metabolism, and viability. The relevant radiochemistry and preclinical and clinical development in addition to molecular imaging with emerging modalities such as cardiac MRI and PET-MR will be discussed.

  20. Measurement of infarct size and percentage myocardium infarcted in a dog preparation with single photon-emission computed tomography, thallium-201, and indium 111-monoclonal antimyosin Fab

    International Nuclear Information System (INIS)

    Johnson, L.L.; Lerrick, K.S.; Coromilas, J.

    1987-01-01

    Single photon-emission tomography (SPECT) and indium 111-labeled monoclonal antimyosin Fab fragments were used to measure myocardial infarct size in 12 dogs, six subjected to balloon catheter-induced coronary artery occlusion for 6 hr (late reperfusion) and six subjected to occlusion with reperfusion at 2 hr (early reperfusion). Tomographic imaging was performed 24 hr after the intravenous injection of labeled Fab fragments with the use of a dual-head SPECT camera with medium-energy collimators. Immediately after the first tomographic scan, thallium-201 was injected into nine of 12 dogs and imaging was repeated. Estimated infarct size in grams was calculated from transaxially reconstructed, normalized, and background-corrected indium SPECT images with the use of a threshold technique for edge detection. Estimated noninfarcted myocardium in grams was calculated from obliquely reconstructed thallium SPECT images by a similar method. The animals were killed and infarct size in grams and true infarct size as a percentage of total left ventricular myocardial volume were measured by triphenyl tetrazolium chloride staining. Estimated infarct size from indium SPECT images showed an excellent correlation with true infarct size (r = .95, SEE = 4.1 g). Estimated percentage myocardium infarcted was calculated by dividing estimated infarct size from indium images by the sum of estimated infarct size plus estimated noninfarcted myocardium obtained from thallium images. Correlation between the estimated percentage of myocardium infarcted and true percentage of myocardium infarcted was excellent

  1. Prediction of 6-year prognosis for cardiac event by thallium-201 single-photon emission computed tomography (SPECT) with treadmill exercise test

    International Nuclear Information System (INIS)

    Hayashi, Katsumi; Ohsuzu, Fumitaka; Kosuda, Shigeru; Nakamura, Haruo

    1997-01-01

    To examine thallium-201 single-photon emission computed tomography (SPECT) with a treadmill exercise test can predict the long-term prognosis of patients with coronary artery disease, 95 patients (71 men, 24 women) who underwent a treadmill exercise test with thallium-201 SPECT from April to December 1986 were followed for 6 years. Three short-axis slices at the apical, mid- and basal-level were selected, and each slice was divided into eight segments. Each segment count was assigned a score according to the count range in the slice (score 0, count range 76-100%; 1, 51-75%; 2, 26-50%; 3, 1-25%; 4, 0%) by evaluating the mean value of the slice. The total Tl defect score of each segment in 3 slices was summed (ΣTl defect score). The 'early ΣTl defect score' was the ΣTl defect score 5 min after treadmill exercise, and the 'late ΣTl defect score' was ΣTl defect score measured 4 h after treadmill exercise. Cardiac events occurred in 27 of the 95 patients: cardiac death 3; myocardial infarction 1; percutaneous transluminal angioplasty 16; coronary artery bypass graft 5; congestive heart failure 3. Univariate analysis showed that previous myocardial infarction (p<0.01), exercise work load (p<0.05), early ΣTl defect score (p<0.0l) and late ΣTl defect score (p<0.01) were independent predictors of the prognosis. These results suggest that thallium-201 SPECT with the treadmill exercise test could be applicable and useful to predict long term prognosis. (author)

  2. Thallium-201 stress imaging in hypertensive patients

    International Nuclear Information System (INIS)

    Schulman, D.S.; Francis, C.K.; Black, H.R.; Wackers, F.J.

    1987-01-01

    To assess the potential effect of hypertension on the results of thallium-201 stress imaging in patients with chest pain, 272 thallium-201 stress tests performed in 133 hypertensive patients and 139 normotensive patients over a 1-year period were reviewed. Normotensive and hypertensive patients were similar in age, gender distribution, prevalence of cardiac risk factors (tobacco smoking, hyperlipidemia, and diabetes mellitus), medications, and clinical symptoms of coronary disease. Electrocardiographic criteria for left ventricular hypertrophy were present in 16 hypertensive patients. Stepwise probability analysis was used to determine the likelihood of coronary artery disease for each patient. In patients with mid to high likelihood of coronary disease (greater than 25% probability), abnormal thallium-201 stress images were present in 54 of 60 (90%) hypertensive patients compared with 51 of 64 (80%) normotensive patients. However, in 73 patients with a low likelihood of coronary disease (less than or equal to 25% probability), abnormal thallium-201 stress images were present in 21 patients (29%) of the hypertensive group compared with only 5 of 75 (7%) of the normotensive patients (p less than 0.001). These findings suggest that in patients with a mid to high likelihood of coronary artery disease, coexistent hypertension does not affect the results of thallium-201 exercise stress testing. However, in patients with a low likelihood of coronary artery disease, abnormal thallium-201 stress images are obtained more frequently in hypertensive patients than in normotensive patients

  3. Myocardial perfusion imaging with Technetium-99m Sestamibi and Thallium-201. Results of the phase III clinical trial

    International Nuclear Information System (INIS)

    Giering, L.; Haber, S.; Joseph, J.L.; Neacy, W.

    1998-01-01

    Full text: Technetium-99m-Sestamibi (MIBI) has been compared to 201 TI and coronary angiography in a large Phase III clinical trial to assess diagnostic accuracy. Exercise and rest planar (P) and SPECT (S) MIBI, and exercise and redistribution thallium-201 studies were performed in 150 healthy volunteers and 396 patients (379 males; mean age 51.3 years). Prior myocardial infarction was present in 50% of the patients. Sensitivity and specificity for angiographically defined cardiovascular diseases - CAD (>70% stenosis) for planar imaging was 90.3% and 81.3% for MIBI and 91.6% and 50.0% for 201 TI. Agreement was 88.7% MIBI and 84.0% for 201 TI. For SPECT imaging, sensitivity and specificity were 95.1% and 46.0% for MIBI and 92.3% and 39.7% for 201 TI. Agreement was 80.0% for MIBI and 76.1% for 201 TI. Tomographic normality rates were 91.4% and 92.9% for MIBI and 201 TI. Agreement for characterisation of defect type by MIBI and 201 TI SPECT was 82.5%. In females, sensitivity was comparable for both agents. Specificity of MIBI planar and SPECT imaging was higher then for 201 TI (P: 90.9% v. 66.7%; S: 76.2% v. 61.9%). The improved imaging characteristics of MIBI results in better diagnostic confidence when interpreting myocardial perfusion studies especially in women and obese patients

  4. The use of thallium-201 scintigraphy in the assessment and management of bone and soft tissue tumours

    International Nuclear Information System (INIS)

    Jong, I.; Schlicht, S.M.; Smith, P.; J Slavin; Powell, G.; Choong, P.F.M.

    2004-01-01

    Introduction: Thallium-201 scintigraphy is routinely performed on all patients presenting to the bone and soft tissue sarcoma service at St. Vincent's Hospital Melbourne. Methods: As part of the multimodality approach to patients presenting to the service, Thallium-201 planar images are obtained at 30 minutes following a resting injection of tracer with delayed planar and where possible SPECT images at 4 hours. Uptake is qualitatively assessed using adjacent muscle uptake at the time of the scan. All thallium-201 scans are read in conjunction with the correlative structural images performed. Results: High grade bone and soft tissue sarcomas typically show significant retention of tracer relative to background activity and adjacent anatomically structures. Benign lesions may show early activity but typically washout on the delayed images. However, some lesions may show marked thallium-201 activity which will be discussed. At our institution the thallium-201 scans are used for assessment of metabolic activity and tumour grade, planning of image guided pre-treatment biopsies and monitoring of treatment response particularly following radiotherapy. Conclusion: Thallium-201 scintigraphy plays a vital role in assessment and management of bone and soft tissue tumours at our institution. (authors)

  5. 5 years prognostic value of dipyridamole-thallium myocardial imaging

    International Nuclear Information System (INIS)

    Yang Yifeng; Qian Zhonghao; Jiang Changying

    1993-01-01

    A prognostic study of dipyridamole-thallium myocardial imaging was conducted with the use of logistic regression. Over a 5 years follow-up period, cardiac events occurred in 13 patients within the 41 patients tested, death in 5 and myocardial infarction in 8. The results of this study indicates that dipyridamole-thallium imaging has significant prognostic utility and that an abnormal scan increased the relative risk for the development of subsequent myocardial infarction or cardiac death (O.R. 18.54). The presence of transient multiple thallium defects further increased the risk of a cardiac event. In conclusion , intravenous dipyridamole thallium imaging is a potentially useful diagnostic test to determine the presence and severity of coronary diseases, and this noninvasive method is also beneficial for prognosis

  6. Clinical utility and problem of thallium myocardial imaging after coronary angioplasty

    International Nuclear Information System (INIS)

    Konishi, Tokuji; Tamai, Takuya; Nakamura, Mashio; Miyahara, Masatoshi; Isaka, Naoki; Nakano, Takeshi.

    1995-01-01

    The purpose of this study was twofold: (1) to assess the value and limits of stress thallium myocardial imaging in the diagnosis of reclosure after percutaneous transluminal coronary angioplasty (PTCA) and (2) to determine how myocardial viability, as determined on thallium imaging, influenced the therapeutic option. In study 1, 117 segments, which were treated with PTCA, were examined. Of 52 segments that showed thallium defects, 27 were treated with repeated PTCA. Of the other 25 segments, 12 were found to be reclosed. On the other hand, 65 other segments showed redistribution on thallium imaging, and 60 of these had no reclosure. The remaining 5 segments that were reclosed reflected no evidence of myocardial viability. These findings suggest that coronary arteriography may omitted when redistribution is seen on stress thallium imaging after PTCA. The population in Study 2 included 39 patients who were diagnosed as having myocardial necrosis on thallium imaging. In 22 of these patients, thallium findings ruled out coronary revascularization. One other patient did not undergo coronary revascularization because of technical problems. Thus, the remaining 16 patients were treated with coronary revascularization combined with bypass surgery for necrotic zones (n=10) or with PTCA for preserved collateral circulation (n=6). For necrotic zones evidenced on thallium imaging, factors other than necrosis were considered in determining coronary revascularization. (N.K.)

  7. Evaluation of usefulness of thallium-201-SPECT and CT images in differential diagnosis between organizing pneumonia and primary lung cancer

    International Nuclear Information System (INIS)

    Nakamura, Kazuhiko; Fujiwara, Yoshio; Ogawa, Hirofumi; Nakano, Kenji; Ogawa, Toshihide

    2007-01-01

    We tried differential diagnosis between organizing pneumonia and primary lung cancer using CT and 201 Tl single photon emission computed tomography (SPECT) images. CT images were estimated margin, air space consolidation, air bronchogram, ground-glass attenuation, spicula and indentation of the lesions. 201 Tl SPECT images were evaluated early and delayed lesion-to-normal contralateral lung uptake ratio (ER and DR) and retention index (RI). Clearness of margin and ground-glass attenuation of CT images of organizing pneumonia were significant different from those of primary lung cancer. On the other hand, DR and RI of organizing pneumonia were significant lower than those of primary lung cancer. We emphasized that 201 Tl SPECT was useful to evaluate differential diagnosis between organizing pneumonia and primary lung cancer. (author)

  8. Left ventricular aneurysm in short axis: a comparison of magnetic resonance, ultrasound and thallium-201 SPECT images

    International Nuclear Information System (INIS)

    Ahmad, M.; Johnson, R.F. Jr.; Fawcett, H.D.; Schreiber, M.H.

    1987-01-01

    Short axis magnetic resonance images of a left ventricular aneurysm were compared to similar views obtained by echocardiography and by thallium-201 single photon emission computed tomography. Images of the dyskinetic left ventricular apex and the contractile left ventricular base were analyzed and compared. Unlike the previously reported orthogonal plane magnetic resonance images, short axis imaging provided representative and quantitative information in views comparable to those obtained by standard noninvasive imaging techniques. These data indicate that short axis magnetic resonance imaging is capable of identifying and sizing the aneurysmal and the residual segments of the left ventricle. The findings may be of prognostic value in patients with left ventricular aneurysm

  9. Brain scintigraphy (SPECT) using 201thallium in patients with primary tumors of the brain

    International Nuclear Information System (INIS)

    Barzen, G.; Schubert, C.; Richter, W.; Calder, D.; Eichstaedt, H.; Felix, R.; Baerwald, M.

    1992-01-01

    We evaluated the role of thallium 201 Single-Photon-Emission-Computed-Tomography (SPECT) in diagnosis, differential diagnosis and follow-up of 33 patients with primary brain tumors. 27 of 33 lesions were detectable by Tl-201-SPECT because only two of eight low-grade (grade 1 and 2) astrocytomas showed Tl-201 accumulation up to a tumor to nontumor ratio of 2.6. High grade (grade 3 and 4) astrocytomas showed Tl-201 accumulation in the range of 2.2 up to 13.0 and were different from low-grade astrocytomas. Noninvasive grading of astrocytomas is therefore possible, whereas differential diagnosis of oligodendrogliomas and astrocytomas or meningeomas was not possible with Tl-201. In the follow-up of six patients, we could demonstrate, that tumor progression is correlated with increasing and tumor regression with decreasing Tl-201 accumulations. This functional changings proceed morphological findings in CT. But vanishing of Tl-201 accumulation during therapy does not mean vanishing of tumor as could be demonstrated by follow-up. (orig.) [de

  10. Thallium reinjection after stress-redistribution imaging. Does 24-hour delayed imaging after reinjection enhance detection of viable myocardium

    International Nuclear Information System (INIS)

    Dilsizian, V.; Smeltzer, W.R.; Freedman, N.M.; Dextras, R.; Bonow, R.O.

    1991-01-01

    Thallium reinjection immediately after conventional stress-redistribution imaging improves the detection of viable myocardium, as many myocardial regions with apparently 'irreversible' thallium defects on standard 3-4-hour redistribution images manifest enhanced thallium uptake after reinjection. Because the 10-minute period between reinjection and imaging may be too short, the present study was designed to determine whether 24-hour imaging after thallium reinjection provides additional information regarding myocardial viability beyond that obtained by imaging shortly after reinjection. We studied 50 patients with chronic stable coronary artery disease undergoing exercise thallium tomography, radionuclide angiography, and coronary arteriography. Immediately after the 3-4-hour redistribution images were obtained, 1 mCi thallium was injected at rest, and images were reacquired at 10 minutes and 24 hours after reinjection. The stress, redistribution, reinjection, and 24-hour images were then analyzed qualitatively and quantitatively. Of the 127 abnormal myocardial regions on the stress images, 55 had persistent defects on redistribution images by qualitative analysis, of which 25 (45%) demonstrated improved thallium uptake after reinjection. At the 24-hour study, 23 of the 25 regions (92%) with previously improved thallium uptake by reinjection showed no further improvement. Similarly, of the 30 regions determined to have irreversible defects after reinjection, 29 (97%) remained irreversible on 24-hour images. These findings were confirmed by the quantitative analysis. The mean normalized thallium activity in regions with enhanced thallium activity after reinjection increased from 57 +/- 13% on redistribution studies to 70 +/- 14% after reinjection but did not change at 24 hours (71 +/- 14%)

  11. Prognostic implications of normal exercise thallium 201 images

    International Nuclear Information System (INIS)

    Wahl, J.M.; Hakki, A.H.; Iskandrian, A.S.

    1985-01-01

    A study was made of 455 patients (mean age, 51 years) in whom exercise thallium 201 scintigrams performed for suspected coronary artery disease were normal. Of those, 322 (71%) had typical or atypical angina pectoris and 68% achieved 85% or more maximal predicted heart rate. The exercise ECGs were abnormal in 68 patients (15%), normal in 229 (50%), and inconclusive in 158 (35%). Ventricular arrhythmias occurred during exercise in 194 patients (43%). After a mean follow-up period of 14 months, four patients had had cardiac events, sudden cardiac death in one and nonfatal myocardial infarctions in three. None of the four patients had abnormal exercise ECGs. Two had typical and two had atypical angina pectoris. Normal exercise thallium 201 images identify patients at a low risk for future cardiac events (0.8% per year), patients with abnormal exercise ECGs but normal thallium images have good prognoses, and exercise thallium 201 imaging is a better prognostic predictor than treadmill exercise testing alone, because of the high incidence of inconclusive exercise ECGs and the good prognosis in patients with abnormal exercise ECGs

  12. Preoperative evaluation of cardiac risk using dobutamine-thallium imaging in vascular surgery

    International Nuclear Information System (INIS)

    Zellner, J.L.; Elliott, B.M.; Robison, J.G.; Hendrix, G.H.; Spicer, K.M.

    1990-01-01

    Coronary artery disease is frequently present in patients undergoing evaluation for reconstructive peripheral vascular surgery. Dobutamine-thallium imaging has been shown to be a reliable and sensitive noninvasive method for the detection of significant coronary artery disease. Eighty-seven candidates for vascular reconstruction underwent dobutamine-thallium imaging. Forty-eight patients had an abnormal dobutamine-thallium scan. Twenty-two patients had infarct only, while 26 had reversible ischemia demonstrated on dobutamine-thallium imaging. Fourteen of 26 patients with reversible ischemia underwent cardiac catheterization and 11 showed significant coronary artery disease. Seven patients underwent preoperative coronary bypass grafting or angioplasty. There were no postoperative myocardial events in this group. Three patients were denied surgery on the basis of unreconstructible coronary artery disease, and one patient refused further intervention. Ten patients with reversible myocardial ischemia on dobutamine-thallium imaging underwent vascular surgical reconstruction without coronary revascularization and suffered a 40% incidence of postoperative myocardial ischemic events. Five patients were denied surgery because of presumed significant coronary artery disease on the basis of the dobutamine-thallium imaging and clinical evaluation alone. Thirty-nine patients with normal dobutamine-thallium scans underwent vascular reconstructive surgery with a 5% incidence of postoperative myocardial ischemia. Dobutamine-thallium imaging is a sensitive and reliable screening method which identifies those patients with coronary artery disease who are at high risk for perioperative myocardial ischemia following peripheral vascular surgery

  13. Clinical usefulness of the technetium-99m/thallium-201 overlap on simultaneous dual SPECT in reperfusion after thrombolytic therapy for acute myocardial infarction

    International Nuclear Information System (INIS)

    Suzuki, Kazuo

    2002-01-01

    In this study, the clinical usefulness of the technetium-99m/thallium-201 ( 99m Tc-PYP/ 201 Tl-Cl) overlap on simultaneous dual SPECT in reperfusion after thrombolytic therapy for acute myocardial infarction was evaluated. The subjects were 14 patients with acute myocardial infarction who had not had myocardial infarction. All patients had chest pain that persisted more than 1 hour and showed electrocardiographic ST elevation. Myocardial scintigraphy was performed on the 4th day of the attack, at 81±35 hours after reperfusion on average. Three hours 50 min after intravenous injection of 740 Mbq 99m Tc-PYP, 111 Mbq 201 Tl-Cl was intravenously injected, and simultaneous dual SPECT was performed after 10 min. In all short axis SPECT image which showed 99m Tc-PYP accumulation, the area of 99m Tc-PYP accumulation (Tc hot), the overlap area of 99m Tc-PYP and 201 Tl-Cl accumulation (overlap), and the total area of 99m Tc-PYP and 201 Tl-Cl accumulation in the short axis SPECT images were calculated. The relationships between these parameters and the peak creatinine kinase (CK), changes in wall motion abnormalities observed by M-mode echocardiography, and the 4-hour delayed image by 201 Tl-Cl exercise scintigraphy performed about one month after the attack were evaluated. The results were both parameters of overlap/Tc hot and overlap/total were negatively correlated with the peak CK, overlap/Tc hot and overlap/total were positively correlated with wall motion scores ratio (WMSR), and overlap/Tc hot was positively correlated with Tl uptake (d)/Tc hot, and the acute overlap region was evaluated to be viable cardiac muscles one month after the attack. These results demonstrated that the 99m Tc-PYP/ 201 Tl-Cl overlap on simultaneous dual SPECT in reperfusion after thrombolytic therapy for acute myocardial infarction indicates the presence of viable cardiac muscles, showing that this method is useful for judgment of the effects of reperfusion. (author)

  14. Molecular imaging agents for SPECT (and SPECT/CT)

    International Nuclear Information System (INIS)

    Gnanasegaran, Gopinath; Ballinger, James R.

    2014-01-01

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  15. Molecular imaging agents for SPECT (and SPECT/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Gnanasegaran, Gopinath [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); Ballinger, James R. [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom)

    2014-05-15

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  16. Thallium-201 myocardial imaging in the detection of coronary artery disease

    International Nuclear Information System (INIS)

    McKillop, J.H.; Murray, R.G.; Turner, J.G.; Gray, H.W.; Bessent, R.G.; Lorimer, A.R.; Greig, W.R.

    1978-01-01

    Thallium-201 myocardial imaging can detect abnormalities of myocardial perfusion. Visual interpretation of the images is complicated by some inhomogeneity of tracer uptake normally present. Using a quantitative approach we have established the regional variation of Thallium-201 uptake present in 23 normal controls and applied the same technique to 49 patients who had undergone selective coronary arteriography with left ventriculography because of chest pain. Half of the patients with significant coronary artery disease had abnormal rest Thallium-201 images, usually corresponding to areas of abnormal wall motion at ventriculography. Stress Thallium-201 images were abnormal in over 90% of patients with coronary artery disease. The stress image abnormalities and the arteriographic lesions correlated well in most patients with single and double vessel disease but in triple vessel disease the correspondence between the two studies was poor. Two of a group of patients with normal coronary arteriograms had abnormal Thallium-201 images due to other myocardial pathology. Our technique was highly sensitive in the non-invasive detection of significant coronary artery disease in a group of patients with chest pain. A small number of positive studies were also encountered due to other myocardial disorders. (author)

  17. Serial Myocardial Imaging after a Single Dose of Thallium-201

    Directory of Open Access Journals (Sweden)

    Takahiko Kamata

    2014-10-01

    Full Text Available Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocardial viability, but also the dynamic changes in myocardial perfusion during angioplasty. Thallium-201 images after exercise showed a perfusion defect in the inferior wall, with a trivial redistribution 3 hours after the exercise and a marked improvement 24 hours later. Coronary angiography, performed 27 hours after exercise scintigraphy, showed severe stenosis in the right coronary artery. Guidewire crossing of the lesion interrupted the antegrade flow, which was restored after balloon dilation and stent implantation. Thallium-201 images, 2 hours after angioplasty (i.e., 30 hours after exercise, showed a decreased tracer uptake in the inferior wall, which improved the next day (i.e., 48 hours after exercise. Cardiac biomarkers were negative in the clinical course.

  18. Late reversibility of tomographic myocardial thallium-201 defects: an accurate marker of myocardial viability

    International Nuclear Information System (INIS)

    Kiat, H.; Berman, D.S.; Maddahi, J.; De Yang, L.; Van Train, K.; Rozanski, A.; Friedman, J.

    1988-01-01

    Twenty-one patients were studied who underwent thallium-201 stress-redistribution single photon emission computed tomography (SPECT) both before and after coronary artery bypass grafting (n = 15) or transluminal coronary angioplasty (n = 6). All patients underwent thallium imaging 15 min, 4 h and late (18 to 72 h) after stress as part of the preintervention thallium-201 scintigram. In a total of 201 tomographic myocardial segments with definite post-stress thallium-201 perfusion defects in which the relevant coronary arteries were subsequently successfully reperfused, the 4 h redistribution images did not predict the postintervention scintigraphic improvement: 67 (85%) of the 79 4 h reversible as well as 88 (72%) of the 122 4 h nonreversible segments improved (p = NS). The 18 to 72 h late redistribution images effectively subcategorized the 4 h nonreversible segments with respect to postintervention scintigraphic improvement: 70 (95%) of the 74 late reversible segments improved after intervention, whereas only 18 (37%) of the 48 late nonreversible segments improved (p less than 0.0001). The frequency of late reversible defects and the frequency of postrevascularization improvement of late nonreversible defects are probably overestimated by this study because of referral biases. The cardiac counts and target to background ratios from late redistribution studies resulted in satisfactory cardiac images for visual interpretation. For optimal assessment of the extent of viable myocardium by thallium-201 scintigraphic studies, late redistribution imaging should be performed when nonreversible defects are observed on 4 h redistribution images

  19. Brain SPECT in children

    International Nuclear Information System (INIS)

    Guyot, M.; Baulieu, J.L.

    1996-01-01

    Brain SPECT in child involves specific trends regarding the patient cooperation, irradiation, resolution and especially interpretation because of the rapid scintigraphic modifications related to the brain maturation. In a general nuclear medicine department, child brain SPECT represents about 2 % of the activity. The choice indications are the perfusion children: thallium and MIBI in brain tumours, pharmacological and neuropsychological interventions. In the future, brain dedicated detectors and new radiopharmaceuticals will promote the development of brain SPECT in children. (author)

  20. SP-ECT imaging and its physical study

    International Nuclear Information System (INIS)

    Kinoshita, Fujimi

    1983-01-01

    Recently, more than a hundred hospitals are provided with SPECT system for clinical examination in Japan. However, a standardization of measuring method and performance test of the systems is ont yet made. We have been studying some basic problems of SPECT system with special phantoms originaly designed by ourselves. We got a conclusion that a standardized phantom is necessary for comparing performances between SPECT systems. In clinical experiences with 3,332 cases, we think that SPECT image combined with conventional image presents much more informations for accurate diagnosis, especially in brain, bone and tumor imagings. Synthesized image of SPECT and XCT, double tracer image and transmission image are useful to visualize the body contour and the clinical diagnosis. (author)

  1. SPECT and PET imaging in epilepsy

    International Nuclear Information System (INIS)

    Semah, F.

    2007-01-01

    Positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging are very useful for the management of patients with medically refractory partial epilepsy. Presurgical evaluation of patients with medically refractory partial epilepsy often included PET imaging using FDG. The use of SPECT in these patients adds some more information and gives the clinicians the possibility of having ictal imaging. Furthermore, PET and SPECT imaging are performed to better understand the pathophysiology of epilepsy. (authors)

  2. Evaluation of myocardial damage in Duchenne's muscular dystrophy with thallium-201 myocardial SPECT

    International Nuclear Information System (INIS)

    Tamura, Takuhisa; Shibuya, Noritoshi; Hashiba, Kunitake; Oku, Yasuhiko; Mori, Hideki; Yano, Katsusuke.

    1993-01-01

    Myocardial damage and cardiopulmonary functions in patients with Duchenne's muscular dystrophy (DMD) were assessed using thallium-201 myocardial single-photon emission computed tomography (SPECT) and technetium-99m multigated radionuclide angiography. Twenty-five patients with DMD were divided into 4 groups according to percent of perfusion defect (%PD) calculated by the bull's-eye method and age. PD was detected in 24 (96.0%) of 25 patients with DMD, and it spread from the left ventricular lateral wall to the anterior wall and/or interventricular septum. PD was detected even in a 6-year-old DMD boy. Patients in Group I (%PD≥10% and age<15 years old) were shown to have a higher risk of left-sided heart failure without respiratory failure. Patients in Group II (%PD≥10 and age≥15) showed decreased pulmonary function and worsened arterial blood gas values as compared with Group IV (%PD<10 and age≥15). There was no significant difference in cardiac function among the 4 groups. It is postulated that myocardial damage in Group II patients is dependent primarily on a deficiency of dystrophin and on chronic respiratory failure, and that some of them are at risk of cardiopulmonary failure. It is concluded that myocardial SPECT is useful for the early diagnosis of myocardial damage and evaluation of cardiopulmonary function in DMD patients. (author)

  3. Brain spect imaging

    International Nuclear Information System (INIS)

    Lee, R.G.L.; Hill, T.C.; Holman, B.L.

    1989-01-01

    This paper discusses how the rapid development of single-photon radiopharmaceuticals has given new life to tomographic brain imaging in nuclear medicine. Further developments in radiopharmaceuticals and refinements in neuro-SPECT (single-photon emission computed tomography) instrumentation should help to reinstate brain scintigraphy as an important part of neurologic diagnosis. SPECT of the brain evolved from experimentation using prototype instrumentation during the early 1960s. Although tomographic studies provided superior diagnostic accuracy when compared to planar techniques, the arrival of X-ray CT of the head resulted in the rapid demise of technetium brain imaging

  4. Comparison of exercise electrocardiography and quantitative thallium imaging for one-vessel coronary artery disease

    International Nuclear Information System (INIS)

    Kaul, S.; Kiess, M.; Liu, P.; Guiney, T.E.; Pohost, G.M.; Okada, R.D.; Boucher, C.A.

    1985-01-01

    The relative value of exercise electrocardiography and computer analyzed thallium-201 imaging was compared in 124 patients with 1-vessel coronary artery disease (CAD). Of these, 78 had left anterior descending (LAD), 32 right and 14 left circumflex (LC) CAD. In patients with no previous myocardial infarction (MI), thallium imaging was more sensitive than the electrocardiogram (78% vs 64%, p less than 0.01), but in patients with previous MI, sensitivity was similar. Further, thallium imaging was more sensitive only in LAD and LC disease. Redistribution was compared with ST-segment depression as a marker of ischemia. Only in patients with prior MI (76% vs 44%, p less than 0.01) and only in LC and right CAD did redistribution occur more often than ST depression. Thallium imaging was more accurate in localizing stenoses than the electrocardiogram (p less than 0.001), but did not always correctly predict coronary anatomy. Septal thallium defects were associated with LAD disease in 84%, inferior defects with right CAD in 40% and posterolateral lesion defects with LC CAD in 22%. The results indicate the overall superiority of thallium imaging in 1-vessel CAD compared with exercise electrocardiography; however, there is a wide spectrum of extent and location of perfusion defects associated with each coronary artery. Thallium imaging complements coronary angiography by demonstrating the functional impact of CAD on myocardial perfusion

  5. Thallium-201 imaging in children with osteogenic sarcoma

    International Nuclear Information System (INIS)

    Parker, M.K.; Koutsiofi, M.; Rossleigh, M.A.

    2003-01-01

    Full text: Thallium(Tl)-201 scintigraphy has been utilised in the imaging of a variety of tumours. This study evaluates its usefulness in children with osteogenic sarcoma. Five patients (3 male, 2 female) whose ages ranged from 11 to 15 years were investigated. Each child underwent a baseline 201 Tl study at diagnosis to determine the initial avidity of the tumour and a follow up study following chemotherapy, just prior to surgical excision, to assess tumour response to chemotherapy. This tumour response was confirmed by histopathological examination of the operative specimen. 201 Tl scintigraphy was undertaken 20 minutes following the intravenous administration of a weight adjusted dose of 201 Tl (minimum dose 20 MBq, adult dose 120 MBq). Whole body studies as well as planar images of the primary tumour were performed. All primary tumours were thallium avid on the baseline study. On the follow-up examination after therapy, a variety of patterns of uptake were seen and these correlated with the pathological findings. In one patient, complete loss of thallium accumulation following treatment corresponded to 100% tumour necrosis histologically. In another patient, persistent thallium uptake in the tumour following chemotherapy correlated with viable tumour cells on pathology and this patient died of his disease. In the other 3 patients, intermediate grade thallium appearances were demonstrated. In conclusion, 201 Tl scintigraphy is an excellent marker of osteogenic sarcoma and follow-up studies after chemotherapy accurately reflect residual tumour activity when correlated with histology. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  6. Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?

    Science.gov (United States)

    Froeling, Vera; Heimann, Uwe; Huebner, Ralf-Harto; Kroencke, Thomas J; Maurer, Martin H; Doellinger, Felix; Geisel, Dominik; Hamm, Bernd; Brenner, Winfried; Schreiter, Nils F

    2015-07-01

    To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.

  7. Exercise thallium imaging in patients with diabetes mellitus. Prognostic implications

    International Nuclear Information System (INIS)

    Felsher, J.; Meissner, M.D.; Hakki, A.H.; Heo, J.; Kane-Marsch, S.; Iskandrian, A.S.

    1987-01-01

    We used exercise thallium 201 imaging in 123 patients with diabetes mellitus (77 men and 46 women, aged 56 +/- 8 years), 75% of whom had angina pectoris (typical or atypical). During exercise testing, 18 patients (15%) had angina pectoris, 28 (23%) had ischemic ST changes, and 69 (56%) had abnormal thallium images. During follow-up (up to 36 months), there were 12 cardiac events; four patients died of cardiac causes and eight had nonfatal acute myocardial infarction. Univariate and multivariate survival analysis identified two independent predictors of cardiac events: the event rate was significantly less in patients with normal images and exercise heart rate over 120 beats per minute than in patients with abnormal images and exercise heart rate of 120 beats per minute or less (0% vs 22%). The patients with abnormal images or exercise heart rate of 120 beats per minute or less had an intermediate event rate (11.5%). Furthermore, two of the 54 patients with normal images and ten of 69 patients with abnormal images had subsequent cardiac events. Thus, exercise thallium imaging is useful in risk stratification in patients with diabetes mellitus

  8. The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.

    Science.gov (United States)

    Okudan, Berna; Smitherman, Thomas C

    2004-06-01

    Myocardial perfusion scintigraphy is an established method in cardiology for the diagnosis and evaluation of coronary artery disease (CAD). Thallium-201 and Tc-99m sestamibi myocardial perfusion imaging has been widely accepted as non-invasive diagnostic procedure for detection of CAD, risk stratification and myocardial viability assessment. But, standard Tl-201 redistribution and same day or 2-day rest/stress Tc-99m sestamibi protocols are time-consuming. Hence, the dual isotope rest thallium-201/stress technetium-99m sestamibi gated single-photon emission tomography protocol has gained increasing popularity for these applications. Combining the use of thallium-201 with technetium-99m agents permits optimal image resolution and simultaneous assessment of viability. Dual-isotope imaging may be separate or simultaneous acquisition set-up. The more rapid completion of these studies is appreciated as an advantage by patients, technologists, interpreting and referring physicians, nurses and hospital management. Simultaneous imaging has the potential advantages of precise pixel registration and artifacts, if present, are identical in both thallium and sestamibi, and require only one set of imaging. Also, there are some disadvantages of spillover of activity from the Tc-99m to the Tl-201 window. Fortunately, despite this problem it can be overcome. Separate acquisition dual isotope also has some disadvantages. Difference in defect resolution in attenuation and scatter between T-201 and Tc-99m sestamibi potentially results in interpretation problems. But, studies about cost-effectiveness of dual isotope imaging showed that some selective elimination of the rest studies may decrease the cost of the nuclear procedures and should be considered in the current care health system.

  9. Thallium-201 myocardial perfusion imaging during adenosine-induced coronary vasodilation in patients with ischemic heart disease

    International Nuclear Information System (INIS)

    Takeishi, Yasuchika; Chiba, Junya; Abe, Shinya

    1992-01-01

    Thallium-201 ( 201 Tl) myocardial perfusion imaging during adenosine infusion was performed in consecutive 55 patients with suspected coronary artery disease. Adenosine was infused intravenously at a rate of 0.14 mg/kg/min for 6 minutes and a dose of 111 MBq of 201 Tl was administered in a separate vein at the end of third minutes of infusion. Myocardial SPECT imaging was begun 5 minutes and 3 hours after the end of adenosine infusion. For evaluating the presence of perfusion defects, 2 short axis images at the basal and spical levels and a vertical long axis image at the mid left ventricle were used. The regions with decreased 201 Tl uptake were assessed semi-quantitatively. Adenosine infusion caused a slight reduction in systolic blood pressure and an increase in heart rate. The rate pressure products increased slightly (9314±2377 vs. 10360±2148, p 201 Tl myocardial imaging during adenosine infusion was considered to be safe and useful for evaluating the patients with ischemic heart disease. (author)

  10. Enhanced detection of ischemic but viable myocardium by the reinjection of thallium after stress-redistribution imaging

    International Nuclear Information System (INIS)

    Dilsizian, V.; Rocco, T.P.; Freedman, N.M.; Leon, M.B.; Bonow, R.O.

    1990-01-01

    The identification of ischemic but viable myocardium by thallium exercise scintigraphy is often imprecise, since many of the perfusion defects that develop in ischemic myocardium during exercise do not fill in on subsequent redistribution images. We hypothesized that a second injection of thallium given after the redistribution images were taken might improve the detection of ischemic but viable myocardium. We studied 100 patients with coronary artery disease, using thallium exercise tomographic imaging and radionuclide angiography. Patients received 2 mCi of thallium intravenously during exercise, redistribution imaging was performed three to four hours later, and a second dose of 1 mCi of thallium was injected at rest immediately thereafter. The three sets of images (stress, redistribution, and reinjection) were then analyzed. Ninety-two of the 100 patients had exercise-induced perfusion defects. Of the 260 abnormal myocardial regions identified by stress imaging, 85 (33 percent) appeared to be irreversible on redistribution imaging three to four hours later. However, 42 of these apparently irreversible defects (49 percent) demonstrated improved or normal thallium uptake after the second injection of thallium, with an increase in mean regional uptake from 56 +/- 12 percent on redistribution studies to 64 +/- 10 percent on reinjection imaging (P less than 0.001). Twenty patients were restudied three to six months after coronary angioplasty. Of the 15 myocardial regions with defects on redistribution studies that were identified as viable by reinjection studies before angioplasty, 13 (87 percent) had normal thallium uptake and improved regional wall motion after angioplasty. In contrast, all eight regions with persistent defects on reinjection imaging before angioplasty had abnormal thallium uptake and abnormal regional wall motion after angioplasty

  11. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  12. SPECT/CT workflow and imaging protocols

    International Nuclear Information System (INIS)

    Beckers, Catherine; Hustinx, Roland

    2014-01-01

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  13. Preoperative evaluation of myocardial viability by thallium-201 imaging in patients with old myocardial infarction who underwent coronary revascularization

    International Nuclear Information System (INIS)

    Naruse, Hitoshi; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Miyamoto, Takashi; Fukuchi, Minoru

    1992-01-01

    The myocardial uptake and redistribution in thallium scintigraphy and the regional wall motion by echocardiography were evaluated by a semi-quantitative method in 42 patients who previously had myocardial infarction (50 target vessels) and underwent coronary revascularization. The aim of this study was to elucidate the significance of the initial image, delayed image and redistribution on thallium-201 scintigraphy for clinical diagnosis of the myocardial viability. As a semi-quantitative analysis, we used a bull's-eye display for thallium image and centerline method for echocardiographic wall motion, and compared the results before and after revascularization. As a result, the thallium grade improved postoperatively in all 17 areas which preoperatively had showed redistribution, and also in 11 of the 32 areas without preoperative redistribution. The sensitivity, specificity and accuracy of preoperative thallium redistribution for predicting myocardial viability were 61%, 100% and 78%, respectively, when the postoperative improvement in the thallium grade was used as the standard. The postoperative probability of improvement in the thallium grade increased in proportion to the preoperative grade (delayed image)(p<0.01). There was no correlation between the preoperative thallium delayed image and postoperative improvement in wall motion. Postoperative improvement in thallium image and wall motion could not be predicted from the preoperative wall motion. Thus, postoperative improvement in thallium images can be anticipated if redistribution is present on the preoperative thallium image, and the preoperative thallium delayed image is useful for predicting myocardial viability. Improvement in wall motion could not be predicted preoperatively by these methods. (author)

  14. Clinical assessment of SPECT/CT co-registration image fusion

    International Nuclear Information System (INIS)

    Zhou Wen; Luan Zhaosheng; Peng Yong

    2004-01-01

    Objective: Study the methodology of the SPECT/CT co-registration image fusion, and Assessment the Clinical application value. Method: 172 patients who underwent SPECT/CT image fusion during 2001-2003 were studied, 119 men, 53 women. 51 patients underwent 18FDG image +CT, 26 patients underwent 99m Tc-RBC Liver pool image +CT, 43 patients underwent 99mTc-MDP Bone image +CT, 18 patients underwent 99m Tc-MAA Lung perfusion image +CT. The machine is Millium VG SPECT of GE Company. All patients have been taken three steps image: X-ray survey, X-ray transmission and nuclear emission image (Including planer imaging, SPECT or 18 F-FDG of dual head camera) without changing the position of the patients. We reconstruct the emission image with X-ray map and do reconstruction, 18FDG with COSEM and 99mTc with OSEM. Then combine the transmission image and the reconstructed emission image. We use different process parameters in deferent image methods. The accurate rate of SPECT/CT image fusion were statistics, and compare their accurate with that of single nuclear emission image. Results: The nuclear image which have been reconstructed by X-ray attenuation and OSEM are apparent better than pre-reconstructed. The post-reconstructed emission images have no scatter lines around the organs. The outline between different issues is more clear than before. The validity of All post-reconstructed images is better than pre-reconstructed. SPECT/CT image fusion make localization have worthy bases. 138 patients, the accuracy of SPECT/CT image fusion is 91.3% (126/138), whereas 60(88.2%) were found through SPECT/CT image fusion, There are significant difference between them(P 99m Tc- RBC-SPECT +CT image fusion, but 21 of them were inspected by emission image. In BONE 99m Tc -MDP-SPECT +CT image fusion, 4 patients' removed bone(1-6 months after surgery) and their relay with normal bone had activity, their morphologic and density in CT were different from normal bones. 11 of 20 patients who could

  15. Assessment of congenital heart disease by a thallium-201 SPECT study in children; Accuracy of estimated right to left ventricular pressure ratio

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Iwao; Nakajima, Kenichi; Taki, Junichi; Taniguchi, Mitsuru; Bunko, Hisashi; Tonami, Norihisa; Hisada, Kinichi; Ohno, Takashi (Kanazawa Univ. (Japan). School of Medicine)

    1993-01-01

    The characteristics of correlation between the right-to-left ventricular systolic pressure ratios (RVp/LVp) and the thallium-201 right-to-left ventricular ([sup 201]Tl R/L) count ratios was investigated in children with various congenital heart diseases. High-resolution three-headed SPECT system equipped with either parallel-hole or fan-beam collimators was used. In a total of 102 patients, the correlation between RVp/LVp and [sup 201]Tl R/L average count ratios was good in both planar (r=0.89, p=0.0001) and SPECT studies (r=0.80, p=0.0001). Quantitative analysis of myocardial uptake by SPECT demonstrated the characteristic pattern of each disease as well as the differences in the right ventricular overload types. When the linear regression analysis was performed in each heart disease, ventricular septal defect showed most excellent correlation. Complex heart anomalies also showed positive correlation (r=0.51, p=0.05) with RVp/LVp, and it can be used to estimate right ventricular pressure. After surgical treatment of tetralogy of Fallot and pulmonary stenosis, the decrease of [sup 201]Tl R/L count ratio was in accordance with improvement of right ventricular overload. We conclude that [sup 201]Tl SPECT study can be a good indicator for estimation of right ventricular pressure. (author).

  16. Correlation between gadolinium-diethylenetriaminepentaacetic acid contrast enhancement and thallium-201 chloride uptake in pediatric brainstem glioma.

    Science.gov (United States)

    Maria, B L; Drane, W B; Quisling, R J; Hoang, K B

    1997-09-01

    We previously showed that thallium-201 (201Tl) chloride is accumulated in over 75% of brain tumors, including brainstem gliomas. The imaging of 201Tl with single photon emission computed tomography (SPECT) may require an abnormal increase in permeability of tumor vessels to allow penetration of the blood-brain barrier. To test this hypothesis, we evaluated the correlation between gadolinium enhancement and the degree of 201Tl uptake on SPECT and the contributions of either gadolinium enhancement or 201Tl uptake to the prognosis in children with brainstem gliomas. Forty-two sets of paired SPECT scans and magnetic resonance imaging (MRI) scans were obtained longitudinally in 13 cases. Altogether, 31 of 42 pairs (74%) of scans showed concordance between the presence of gadolinium enhancement and 201Tl uptake. There were no cases that demonstrated 201Tl uptake but lacked gadolinium enhancement. The results indicate that 201Tl SPECT is of value primarily when brainstem tumors have vessels that are demonstrably permeable to gadolinium, prior to or as a result of radiotherapy.

  17. Evaluation of myocardial damage in Duchenne's muscular dystrophy with thallium-201 myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Takuhisa; Shibuya, Noritoshi (Kawatana National Hospital, Nagasaki (Japan)); Hashiba, Kunitake; Oku, Yasuhiko; Mori, Hideki; Yano, Katsusuke

    1993-01-01

    Myocardial damage and cardiopulmonary functions in patients with Duchenne's muscular dystrophy (DMD) were assessed using thallium-201 myocardial single-photon emission computed tomography (SPECT) and technetium-99m multigated radionuclide angiography. Twenty-five patients with DMD were divided into 4 groups according to percent of perfusion defect (%PD) calculated by the bull's-eye method and age. PD was detected in 24 (96.0%) of 25 patients with DMD, and it spread from the left ventricular lateral wall to the anterior wall and/or interventricular septum. PD was detected even in a 6-year-old DMD boy. Patients in Group I (%PD[>=]10% and age<15 years old) were shown to have a higher risk of left-sided heart failure without respiratory failure. Patients in Group II (%PD[>=]10 and age[>=]15) showed decreased pulmonary function and worsened arterial blood gas values as compared with Group IV (%PD<10 and age[>=]15). There was no significant difference in cardiac function among the 4 groups. It is postulated that myocardial damage in Group II patients is dependent primarily on a deficiency of dystrophin and on chronic respiratory failure, and that some of them are at risk of cardiopulmonary failure. It is concluded that myocardial SPECT is useful for the early diagnosis of myocardial damage and evaluation of cardiopulmonary function in DMD patients. (author).

  18. Evaluation of pulmonary emphysema by the fused image of CT image and ventilation SPECT image

    International Nuclear Information System (INIS)

    Okuda, Ituko; Maruno, Hiromasa; Mori, Kazuaki; Kohno, Tadashi; Kokubo, Takashi

    2007-01-01

    We evaluated pulmonary emphysema using a diagnostic device that could obtain a CT image, a ventilation single photon emission computed tomography (SPECT) image and a lung perfusion SPECT image in one examination. The fused image made from the CT image and SPECT image had very little position gap between images, and the precision was high. From the fused image, we were able to detect the areas in which emphysematous change was the most marked in the CT image, while the accumulation decrease was most remarkable in the ventilation SPECT image. Thus it was possible to obtain an accurate status of pulmonary emphysema, and our method was regarded as a useful technique. (author)

  19. Myocardial imaging in coronary heart disease with radionuclides, with emphasis on thallium-201

    Energy Technology Data Exchange (ETDEWEB)

    Wackers, F J.Th.; Sokole, E B; Samson, G; van der Schoot, J B; Wellens, H J.J. [Amsterdam Univ. (Netherlands). Academisch Ziekenhuis

    1976-09-01

    During the past few years there has been an increasing interest in cardiology for myocardial imaging with radionuclides. At present the experience with both negative (thallium-201) and positive (sup(99m)Tc-pyrophosphate) imaging of myocardial infarction is increasing rapidly. Since 1974, over 1100 patient studies with thallium-201 were performed. In this article a survey is presented of experience with thallium-201 in patients with acute and chronic coronary artery disease. In patients with acute myocardial infarction data from studies with sup(99m)Tc-pyrophosphate will be discussed as well.

  20. A small-animal imaging system capable of multipinhole circular/helical SPECT and parallel-hole SPECT

    International Nuclear Information System (INIS)

    Qian Jianguo; Bradley, Eric L.; Majewski, Stan; Popov, Vladimir; Saha, Margaret S.; Smith, Mark F.; Weisenberger, Andrew G.; Welsh, Robert E.

    2008-01-01

    We have designed and built a small-animal single-photon emission computed tomography (SPECT) imaging system equipped with parallel-hole and multipinhole collimators and capable of circular or helical SPECT. Copper-beryllium parallel-hole collimators suitable for imaging the ∼35 keV photons from the decay of 125 I have been built and installed to achieve useful spatial resolution over a range of object-detector distances and to reduce imaging time on our dual-detector array. To address the resolution limitations in the parallel-hole SPECT and the sensitivity and limited field of view of single-pinhole SPECT, we have incorporated multipinhole circular and helical SPECT in addition to expanding the parallel-hole SPECT capabilities. The pinhole SPECT system is based on a 110 mm diameter circular detector equipped with a pixellated NaI(Tl) scintillator array (1x1x5 mm 3 /pixel). The helical trajectory is accomplished by two stepping motors controlling the rotation of the detector-support gantry and displacement of the animal bed along the axis of rotation of the gantry. Results obtained in SPECT studies of various phantoms show an enlarged field of view, very good resolution and improved sensitivity using multipinhole circular or helical SPECT. Collimators with one, three and five, 1-mm-diameter pinholes have been implemented and compared in these tests. Our objective is to develop a system on which one may readily select a suitable mode of either parallel-hole SPECT or pinhole circular or helical SPECT for a variety of small animal imaging applications

  1. Computer-assisted superimposition of magnetic resonance and high-resolution technetium-99m-HMPAO and thallium-201 SPECT images of the brain

    International Nuclear Information System (INIS)

    Holman, B.L.; Zimmerman, R.E.; Johnson, K.A.; Carvalho, P.A.; Schwartz, R.B.; Loeffler, J.S.; Alexander, E.; Pelizzari, C.A.; Chen, G.T.

    1991-01-01

    A method for registering three-dimensional CT, MR, and PET data sets that require no special patient immobilization or other precise positioning measures was adapted to high-resolution SPECT and MRI and was applied in 14 subjects [five normal volunteers, four patients with dementia (Alzheimer's disease), two patients with recurrent glioblastoma, and three patients with focal lesions (stroke, arachnoid cyst and head trauma)]. T2-weighted axial magnetic resonance images and transaxial 99mTc-HMPAO and 201Tl images acquired with an annular gamma camera were merged using an objective registration (translation, rotation and rescaling) program. In the normal subjects and patients with dementia and focal lesions, focal areas of high uptake corresponded to gray matter structures. Focal lesions observed on MRI corresponded to perfusion defects on SPECT. In the patients who had undergone surgical resection of glioblastoma followed by interstitial brachytherapy, increased 201Tl corresponding to recurrent tumor could be localized from the superimposed images. The method was evaluated by measuring the residuals in all subjects and translational errors due to superimposition of deep structures in the 12 subjects with normal thalamic anatomy and 99mTc-HMPAO uptake. This method for superimposing magnetic resonance and high-resolution SPECT images of the brain is a useful technique for correlating regional function with brain anatomy

  2. Sex differences in the tracer distribution on stress thallium-201 imaging, (1)

    International Nuclear Information System (INIS)

    Tamaki, Nagara; Koda, Hideki; Adachi, Yukihide; Sugihara, Takao; Kato, Mihoko; Tanaka, Nobuyuki; Tamari, Kimimasa.

    1988-01-01

    To determine the sex differences in the tracer distribution on stress thallium-201 imaging, the studies of 18 normal males and 18 normal females were subjected to quantitative circumferential profile analysis in each projection image. Although the exercise duration was shorter in females (11±3 min) than in males (14±3 min) (p<0.01), the peak heart rate, peak systolic pressure and the lung-to-myocardial count ratio were similar between them. The averaged profile curves in female showed a significant reduction in tracer uptake in anterior and upper septal regions, particularly in the study of lateral view, which may be attributed to breast attenuation. In addition, the percent washout of thallium in 3 hours was higher in females (48±8%) than in males (43±7%) (p<0.01), particularly in the study of anterior view. We conclude that important differences in the pattern of thallium uptake and washout between males and females should be considered for interpretation of stress thallium imaging. (author)

  3. SPECT data acquisition and image reconstruction in a stationary small animal SPECT/MRI system

    Science.gov (United States)

    Xu, Jingyan; Chen, Si; Yu, Jianhua; Meier, Dirk; Wagenaar, Douglas J.; Patt, Bradley E.; Tsui, Benjamin M. W.

    2010-04-01

    The goal of the study was to investigate data acquisition strategies and image reconstruction methods for a stationary SPECT insert that can operate inside an MRI scanner with a 12 cm bore diameter for simultaneous SPECT/MRI imaging of small animals. The SPECT insert consists of 3 octagonal rings of 8 MR-compatible CZT detectors per ring surrounding a multi-pinhole (MPH) collimator sleeve. Each pinhole is constructed to project the field-of-view (FOV) to one CZT detector. All 24 pinholes are focused to a cylindrical FOV of 25 mm in diameter and 34 mm in length. The data acquisition strategies we evaluated were optional collimator rotations to improve tomographic sampling; and the image reconstruction methods were iterative ML-EM with and without compensation for the geometric response function (GRF) of the MPH collimator. For this purpose, we developed an analytic simulator that calculates the system matrix with the GRF models of the MPH collimator. The simulator was used to generate projection data of a digital rod phantom with pinhole aperture sizes of 1 mm and 2 mm and with different collimator rotation patterns. Iterative ML-EM reconstruction with and without GRF compensation were used to reconstruct the projection data from the central ring of 8 detectors only, and from all 24 detectors. Our results indicated that without GRF compensation and at the default design of 24 projection views, the reconstructed images had significant artifacts. Accurate GRF compensation substantially improved the reconstructed image resolution and reduced image artifacts. With accurate GRF compensation, useful reconstructed images can be obtained using 24 projection views only. This last finding potentially enables dynamic SPECT (and/or MRI) studies in small animals, one of many possible application areas of the SPECT/MRI system. Further research efforts are warranted including experimentally measuring the system matrix for improved geometrical accuracy, incorporating the co

  4. Determination of cardiac risk by dipyridamole-thallium imaging before peripheral vascular surgery

    International Nuclear Information System (INIS)

    Boucher, C.A.; Brewster, D.C.; Darling, R.C.; Okada, R.D.; Strauss, H.W.; Pohost, G.M.

    1985-01-01

    To evaluate the severity of coronary artery disease in patients with severe peripheral vascular disease requiring surgery, preoperative dipyridamole-thallium imaging was performed in 54 stable patients with suspected coronary artery disease. Of the 54 patients, 48 had peripheral vascular surgery as scheduled without coronary angiography, of whom 8 (17 per cent) had postoperative cardiac ischemic events. The occurrence of these eight cardiac events could not have been predicted preoperatively by any clinical factors but did correlate with the presence of thallium redistribution. Eight of 16 patients with thallium redistribution had cardiac events, whereas there were no such events in 32 patients whose thallium scan either was normal or showed only persistent defects (P less than 0.0001). Six other patients also had thallium redistribution but underwent coronary angiography before vascular surgery. All had severe multivessel coronary artery disease, and four underwent coronary bypass surgery followed by uncomplicated peripheral vascular surgery. These data suggest that patients without thallium redistribution are at a low risk for postoperative ischemic events and may proceed to have vascular surgery. Patients with redistribution have a high incidence of postoperative ischemic events and should be considered for preoperative coronary angiography and myocardial revascularization in an effort to avoid postoperative myocardial ischemia and to improve survival. Dipyridamole-thallium imaging is superior to clinical assessment and is safer and less expensive than coronary angiography for the determination of cardiac risk

  5. Myocardial infarction after dipyridamole-assisted thallium-201 imaging

    International Nuclear Information System (INIS)

    Biddle, P.; Lanspa, T.J.; Mohiuddin, S.M.; Malesker, M.A.; Hilleman, D.E.

    1989-01-01

    A 77-year-old woman with suspected coronary artery disease underwent an oral dipyridamole/thallium-201 myocardial imaging study. Approximately 75 minutes after ingestion of dipyridamole 300 mg suspension, the patient developed chest pain, hypotension, nausea, and diaphoresis. An electrocardiogram revealed ST-T wave changes suggestive of inferior ischemia. Appropriate therapeutic measures, including aminophylline and nitroglycerin, were instituted. Delayed thallium images revealed reversible ischemia in the anteroseptal and posterobasal regions with a fixed defect in the inferobasal region. Cardiac enzyme studies were also indicative of acute myocardial injury. The patient subsequently underwent coronary arteriography and four-vessel coronary artery bypass grafting and was discharged without further complication. This report raises concerns about the potential danger of dipyridamole in patients with severe coronary artery stenosis and collateral circulation. Prophylactic aminophylline should be considered in these patients

  6. Serial thallium-201 imaging after dipyridamole for coronary disease detection: quantitative analysis using myocardial clearance

    International Nuclear Information System (INIS)

    Okada, R.D.; Dai, Y.H.; Boucher, C.A.; Pohost, G.M.

    1984-01-01

    After dipyridamole, canine studies have demonstrated a slower rate of myocardial thallium-201 clearance from zones distal to a coronary artery stenosis compared to normal zones. To determine if criteria based on canine myocardial thallium-201 clearance rates could be applied clinically, 40 patients with and 26 patients without coronary artery disease (CAD) had serial thallium-201 images obtained for 2 to 5 hours after dipyridamole. Regions of interest were manually placed over six left ventricular segments in two projections for each of three imaging times. The myocardial thallium-201 clearance rate was calculated for each of the six segments and, using the clearance rate criterion found in canine studies, was considered abnormal if less than 6.5%/hr. Using this criterion alone, 22 of 26 patients (85%) without CAD had normal and 30 of 40 patients (75%) with CAD had abnormal myocardial thallium-201 clearance rates. A quantitative analysis of regional inhomogeneity in tracer distribution (normal was greater than or equal to 25% difference between segments) was negative in 24 of 26 patients (92%) without CAD and positive in 20 of 40 patients (50%) with CAD. When both clearance rate and regional inhomogeneity were considered, 21 of 26 patients (81%) without CAD had negative and 36 of 40 patients (90%) with CAD had positive results. Thus, post-dipyridamole myocardial clearance rate criteria derived from canine studies can be applied to clinical thallium imaging. Quantitative analysis of serial thallium-201 images after dipyridamole is optimized by using myocardial thallium-201 clearance rates. Such an approach is independent of regional inhomogeneities in tracer distribution

  7. SPECT imaging with resolution recovery

    International Nuclear Information System (INIS)

    Bronnikov, A. V.

    2011-01-01

    Single-photon emission computed tomography (SPECT) is a method of choice for imaging spatial distributions of radioisotopes. Many applications of this method are found in nuclear industry, medicine, and biomedical research. We study mathematical modeling of a micro-SPECT system by using a point-spread function (PSF) and implement an OSEM-based iterative algorithm for image reconstruction with resolution recovery. Unlike other known implementations of the OSEM algorithm, we apply en efficient computation scheme based on a useful approximation of the PSF, which ensures relatively fast computations. The proposed approach can be applied with the data acquired with any type of collimators, including parallel-beam fan-beam, cone-beam and pinhole collimators. Experimental results obtained with a micro SPECT system demonstrate high efficiency of resolution recovery. (authors)

  8. Lung uptake of thallium-201 on resting myocardial imaging in assessment of pulmonary edema

    Energy Technology Data Exchange (ETDEWEB)

    Tamaki, N.; Yonekura, Y.; Yamamoto, K. (Kyoto Univ. (Japan). Hospital)

    1981-03-01

    We have noted increased lung uptake of thallium-201 on resting myocardial images in patients with congestive heart failure. To evaluate this phenomenon, lung uptake of thallium on resting myocardial imaging was examined in 328 patients with various cardiovascular diseases. Increased lung uptake was observed in 117 cases (78%) with myocardial infarction, 32 (37%) with angina pectoris, 6 (27%) with hypertensive heart disease, 7 (30%) with hypertrophic cardiomyopathy, 6 (100%) with congestive cardiomyopathy, 11 (100%) with valvular heart disease, and 7 (71%) with congenital heart disease, however, only one (5%) of normal subjects revealed increased uptake. Left ventricular ejection fraction was evaluated in 32 cases with ischemic heart disease on the same day and it was significantly decreased as the lung uptake of thallium increased. Increased thallium activity in the lung seemed to be another noninvasive marker of lift heart failure in ischemic heart disease. Lung uptake of thallium was compared with pulmonary congestive signs on chest X-ray in 29 cases. The uptake was well correlated with the degree of pulmonary edema, and thallium myocardial image revealed remarkably increased lung uptake in all the patients accompanied with pulmonary interstitial edema on chest X-ray. Therefore, this phenomenon will demonstrate pulmonary edema, since thallium may be extracted to the increased interstitial distribution space of the lung as well as the myocardium in a patient with pulmonary edema. We conclude that thallium myocardial scintigraphy is useful not only in identification and localization of myocardial ischemia or infarction, but also in evaluation of pulmonary edema at the same time.

  9. Lung uptake of thallium-201 on resting myocardial imaging in assessment of pulmonary edema

    International Nuclear Information System (INIS)

    Tamaki, Nagara; Yonekura, Yoshiharu; Yamamoto, Kazutaka

    1981-01-01

    We have noted increased lung uptake of thallium-201 on resting myocardial images in patients with congestive heart failure. To evaluate this phenomenon, lung uptake of thallium on resting myocardial imaging was examined in 328 patients with various cardiovascular diseases. Increased lung uptake was observed in 117 cases (78%) with myocardial infarction, 32 (37%) with angina pectoris, 6 (27%) with hypertensive heart disease, 7 (30%) with hypertrophic cardiomyopathy, 6 (100%) with congestive cardiomyopathy, 11 (100%) with valvular heart disease, and 7 (71%) with congenital heart disease, however, only one (5%) of normal subjects revealed increased uptake. Left ventricular ejection fraction was evaluated in 32 cases with ischemic heart disease on the same day and it was significantly decreased as the lung uptake of thallium increased. Increased thallium activity in the lung seemed to be another noninvasive marker of lift heart failure in ischemic heart disease. Lung uptake of thallium was compared with pulmonary congestive signs on chest X-ray in 29 cases. The uptake was well correlated with the degree of pulmonary edema, and thallium myocardial image revealed remarkably increased lung uptake in all the patients accompanied with pulmonary interstitial edema on chest X-ray. Therefore, this phenomenon will demonstrate pulmonary edema, since thallium may be extracted to the increased interstitial distribution space of the lung as well as the myocardium in a patient with pulmonary edema. We conclude that thallium myocardial scintigraphy is useful not only in identification and localization of myocardial ischemia or infarction, but also in evaluation of pulmonary edema at the same time. (author)

  10. assessment of the clinical role of simultaneous 99mTc-MIBI and 201Tl dual-isotopic myocardial perfusion SPECT imaging in the patients wit hypertension

    International Nuclear Information System (INIS)

    Xie Wenhui; Zhang Lihua; Hu Shilong; Yang Shunfang; Zeng Jun

    2004-01-01

    Objective: To study the clinical role of Simultaneous rest technetium-99m sestamibi ( 99m Tc-MIBI) and stress thallium-201 (201Tl) Dual-isotopic myocardial perfusion SPECT imaging in the patients with hypertension. Methods: 116 patients with high blood pressure underwent simultaneous dual-isotopic myocardial perfusion SPECT imaging with 99m Tc-MIBI and 201Tl. 99m Tc-MIBI was injected at rest, 15 min later dobutamine was instilled into vein begin with 5 mg/kg/min, before and after instilling the base ECG, blood pressure, heart rate was recorded. when the maximal dose of Dobutamine was achieved, thallium-201 was injected, the dual-isotopic simultaneously SPECT imagine was performed. The stress and rest imagine was obtained. After tomographic reconstruction, the images were interpreted by two experienced observers without previous knowledge of results of other studies. Coronary angiography was performed in two weeks. All of 116 patients were found normal. Results: (1) All of 116 patients with high blood pressure were divided as three group by the course of disease: A group ( 20 year), 15. The heart/lung ratios of A, B, C group were 2.651±0.246, 2.546±0.231, 2.490±0.36 (mean±SD)respectively, no significant difference was noted among three group. Normal heart/lung ratios is 2.50±0.28 among of control group of 20. (2) The overall sensitivity for the dual-isotopic simultaneously myocardial SPECT imagine of high blood pressure was 46.55%(54/116). (3) Anterior, lateral, inferior, apex, interventricular septal segment were regarded as a whole segment, 111 segments display abnormal 201Tl uptake. 63, 30, 18 segments were in A, B, C group respectively, and no significant difference was noted among three group. 4 85 segments reveal reduced stressing 201Tl uptake and no typical redistribution was observed in the delay 201Tl imagines. 20, 24, 14, 12, 15 segments were in anterior, lateral, inferior, apex, interventricular septal segment respectively. 26 segments display

  11. Myocardial viability assessed by Tl-201 SPECT. Redistribution versus reinjection

    International Nuclear Information System (INIS)

    Chalela, William Azem; Pimentel, Flavio Ferrarini de Oliveira; Uchida, Augusto Hiroshi; Bottega, Augusto; Ramires, Jose Antonio Franchine; Izaki, Marisa; Moraes, Aguinaldo Pereira; Soares Junior, Jose; Giorgi, Maria C. Pinto; Moffa, Paulo Jorge; Bellotti, Giovanni; Giovanni Guido Cerri; Meneghetti, Jose Claudio

    1994-01-01

    The purpose of this study was to verify if a third series of images acquired by reinjection thallium-201, 24 h after conventional myocardial perfusion with the radioisotope, improves the identification of myocardial viability segments. The methods: we studied 30 patients, mean age 57.7 ±9.4 years, with old myocardial infarction using thallium (Tl)-201 SPECT, and we obtained three series of images (stress, redistribution after 4 h and reinjection after 24 h. Cardiac images were divided in 5 segments (apical, lateral, anterior, septal and inferior) and each one received a value by a score system according to the Tl-201 myocardial uptake (0=normal uptake; 1=mild hypoperfusion; 2=moderate hypoperfusion; 3=severe hypoperfusion or no myocardial uptake). We considered viable myocardium when the uptake of Tl-201 in the segment related to te myocardial infarction increases at least 1 point in two different axis of Tl-201 SPECT. The results: seven (23,3%) patients demonstrated increase of Tl-201 uptake only at reinjection images, showing a high efficacy of the method. Nine (30%) patients showed persistent hypoperfusion at all series of images suggesting only fibrosis in the are related to the infarction. Fourteen (46,7%) patients showed increase of Tl-201 concentration at redistribution images; among these patients, six showed improvement of myocardial uptake at reinjection. This condition was interpreted as regional chronic ischemic process: hibernating myocardium. The conclusion was that Tl-201 hypoperfusion at redistribution images without significant changes in relation to the stress images do not represent fibrosis at all. The reinjection technic was better than conventional redistribution in the detection of viable myocardium. This data allows a better therapeutic orientation. (author)

  12. Decrease in the ability to detect elevated lung thallium due to delay in commencing imaging after exercise

    International Nuclear Information System (INIS)

    Rothendler, J.A.; Boucher, C.A.; Strauss, H.W.; Pohost, G.M.; Okada, R.D.

    1985-01-01

    Post-exercise elevation of the lung/myocardial thallium ratio and a high lung clearance rate between initial and delayed images have been reported to be markers for exercise-induced left ventricular (LV) dysfunction associated with coronary artery disease (CAD). The authors performed thallium exercise tests on 60 patients, 42 with CAD, in order to determine the effect of delaying initial imaging on detection of elevated lung thallium. In addition to images obtained at 2 minutes and at 2 hours after exercise, 18-minute images were also obtained to simulate such a delay. Because of rapid isotope clearance in those with initially elevated lung activity, there was decreased sensitivity of both the initial lung/myocardial ratio and lung thallium clearance for detecting CAD, using the 18-minute image as the initial post exercise study. They conclude that initial imaging should be done in the anterior view early after exercise to optimize detection of elevated lung thallium

  13. Role of exercise thallium 201 imaging in decision making

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Segal, B.L.; Frankl, W.S.; Kane-Marsch, S.; Unger, J.

    1986-01-01

    This prospective study examined the impact of results of exercise thallium 201 imaging on the estimation of probability of coronary artery disease (CAD) and patient management among cardiologists and internists in our institution. Before exercise testing, the probability of CAD in the 100 patients enrolled in this study was considered low in 31, intermediate in 28, and high in 41 patients. The probability of CAD after exercise thallium imaging was different in four patients (10%) in the high group, 22 patients (79%) in the intermediate group, and three patients (10%) in the low group. Further, the results of exercise testing resulted in changes in patient management in 29 patients (71%) in the high group, 26 patients (93%) in the intermediate group, and 16 patients (52%) in the low group. Overall, the management changed in 71% of the patients. This change included changes in medications, physical activity, frequency of office visits, need for cardiac catheterization, and need for coronary arterial bypass grafting. Thus, exercise thallium imaging is useful in clinical decision making: the diagnostic certainty is improved in patients with intermediate pretest probability of CAD; and some degree of change in patient management is observed, even in patients in whom the probability of CAD is not altered

  14. Differentiation of malignant glioma and metastatic brain tumor by thallium-201 single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, Yasuhiro; Kuwana, Nobumasa; Noji, Masato; Tosa, Junichi [Yokohama Minami Kyosai Hospital (Japan)

    1994-09-01

    The use of superdelayed thallium-201 single photon emission computed tomography ([sup 201]Tl SPECT) for differentiating malignant gliomas from cerebral metastases was investigated in 23 patients (7 with meningioma, 6 with glioma, 7 with cerebral metastasis, 1 with each of neurinoma, abscess, and necrosis). 4 mCi of [sup 201]Tl was injected intravenously, and gamma camera scans were performed after 10 minutes and 4, 24, 72, and 96 hours (superdelayed scan). The mean thallium index of meningiomas was significantly higher than those of gliomas and cerebral metastases after 10 minutes, while the mean thallium indices of meningiomas and gliomas were significantly higher than those of cerebral metastases after 96 hours. The combination of early and superdelayed [sup 201]Tl SPECT may be useful in differentiating malignant gliomas from cerebral metastases. (author).

  15. Technical approach to improvement of SPECT images

    International Nuclear Information System (INIS)

    Fukukita, Hiroyoshi

    1985-01-01

    At present, a large number of SPECT systems are being widely used in Japan, hence, it is reasonable for us to know the physical and imaging characteristics of these SPECT devices, and also to recommend the optimum utility of SPECT systems. For this reason, a survey respect of characteristics of the commercialy available SPECT devices was carried out. In addition to this, various factors which have significant influence over SPECT image quality, such as, data acquisition matrix, reconstruction filter, γ-ray attenuation correction and daily quality control procedure, were also investigated. The materials used for this study are PET/SPECT phantom, Alderson liver phantom filled with Tc-99m solution, and either LFOV-E or ZLC-7500 interfaced to Scintipac 2400 minicomputer with 256 K byte of memory. Following are the results of this study. 1) The suitable data acquisition procedure was 128 x 128 matrix for linear sampling and approximately 64 views for angular sampling. 2) Reconstructed image using pre-processing filter with Wiener and Butterworth filters provided high quality image as compared with the Ramp filter. 3) Weighted backprojection method (WBP) proposed by Tanaka was superior to other methods, such as Sorenson method and Chang method in the object with non-uniform distribution of radionuclide. 4) It was found that uniformity correction of gamma camera and precise adjustment of the center of rotation are most important to maintain the images with a high quality. (author)

  16. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  17. The clinical use of brain SPECT imaging in neuropsychiatry

    International Nuclear Information System (INIS)

    Amen, Daniel G; Wu, Joseph C; Carmichael, Blake

    2003-01-01

    This article reviews the literature on brain SPECT imaging in brain trauma, dementia, and temporal lobe epilepsy. Brain SPECT allows clinicians the ability to view cerebral areas of healthy, low, and excessive perfusion. This information can be correlated with what is known about the function or dysfunction of each area. SPECT has a number of advantages over other imaging techniques, including wider availability, lower cost, and high quality resolution with multi-headed cameras. There are a number of issues that compromise the effective use of SPECT, including low quality of some imaging cameras, and variability of image rendering and readings (Au)

  18. Prevalence and correlates of increased lung/heart ratio of thallium-201 during dipyridamole stress imaging for suspected coronary artery disease

    International Nuclear Information System (INIS)

    Villanueva, F.S.; Kaul, S.; Smith, W.H.; Watson, D.D.; Varma, S.K.; Beller, G.A.

    1990-01-01

    There is little information concerning the prevalence and clinical correlates of increased pulmonary thallium-201 uptake during dipyridamole thallium-201 stress imaging. Accordingly, the clinical characteristics and quantitative thallium-201 findings were correlated with quantitative lung/heart thallium-201 ratio in 87 patients undergoing dipyridamole thallium-201 stress testing. Nineteen patients (22%) had an elevated ratio (greater than 0.51). These patients were more likely to have had an infarction, to be taking beta blockers, and have a lower rate-pressure product after dipyridamole administration than those with a normal ratio (p less than 0.03). An elevated ratio was associated with a greater likelihood of initial, redistribution and persistent defects, as well as left ventricular cavity dilatation on thallium-201 imaging (p less than 0.05). In addition, the number of myocardial segments demonstrating initial, redistribution and persistent defects was also greater in patients with increased ratios (p less than 0.03). Multivariate analysis demonstrated that the presence of redistribution and left ventricular cavity dilatation were the most significant correlates of lung/heart thallium-201 ratio. It is concluded that the prevalence of increased lung/heart thallium-201 ratio with dipyridamole thallium-201 stress imaging is similar to that seen with exercise stress imaging. As with exercise thallium-201 imaging, increased pulmonary thallium-201 uptake may be a marker of functionally more significant coronary artery disease

  19. Comparative study of thallium-201 single-photon emission computed tomography and electrocardiography in Duchenne and other types of muscular dystrophy

    International Nuclear Information System (INIS)

    Yamamoto, S.; Matsushima, H.; Suzuki, A.; Sotobata, I.; Indo, T.; Matsuoka, Y.

    1988-01-01

    Single-photon emission computed tomography (SPECT) using thallium-201 was compared with 12-lead electrocardiography (ECG) in patients with Duchenne (29), facioscapulohumeral (7), limb-girdle (6) and myotonic (5) dystrophies, by dividing the left ventricular (LV) wall into 5 segments. SPECT showed thallium defects (37 patients, mostly in the posteroapical wall), malrotation (23), apical aneurysm (5) and dilatation (7). ECG showed abnormal QRS (36 patients), particularly as a posterolateral pattern (13). Both methods of assessment were normal in only 7 patients. The Duchenne type frequently showed both a thallium defect (particularly in the posteroapical wall) and an abnormal QRS (predominantly in the posterolateral wall); the 3 other types showed abnormalities over the 5 LV wall segments in both tests. The percent of agreement between the 2 tests was 64, 66, 70, 72 and 72 for the lateral, apical, anteroseptal, posterior and inferior walls, respectively. The 2 tests were discordant in 31% of the LV wall, with SPECT (+) but ECG (-) in 21% (mostly in the apicoinferior wall) and SPECT (-) but ECG (+) in 10% (mostly in the lateral wall). Some patients showed large SPECT hypoperfusion despite minimal electrocardiographic changes. ECG thus appeared to underestimate LV fibrosis and to reflect posteroapical rather than posterolateral dystrophy in its posterolateral QRS pattern. In this disease, extensive SPECT hypoperfusion was also shown, irrespective of clinical subtype and skeletal involvement

  20. Stereotactic radiosurgery planning with ictal SPECT images

    International Nuclear Information System (INIS)

    Ackerly, T.; RMIT University, Bundoora, VIC; Geso, M.; O'Keefe, G.; Smith, R.

    2004-01-01

    This paper is motivated by a clinical requirement to utilise ictal SPECT images for target localisation in stereotactic radiosurgery treatment planning using the xknife system which only supports CT and MRI images. To achieve this, the SPECT images were converted from raw (pixel data only) format into a part 10 compliant DICOM CT fileset. The minimum requirements for the recasting of a raw format image as DICOM CT or MRI data set are described in detail. The method can be applied to the importation of raw format images into any radiotherapy treatment planning system that supports CT or MRI import. It is demonstrated that the combination of the low spatial resolution SPECT images, depicting functional information, with high spatial resolution MRI images, which show the structural information, is suitable for stereotactic radiosurgery treatment planning. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  1. Study on SPECT image for children with cerebral infarction

    International Nuclear Information System (INIS)

    Xie Wenhuang; Xie Zhichun; Chen Yucai; Lin Haoxue; Zheng Aidong; Xie Hui

    1998-01-01

    To explore the diagnostic value of SPECT image for children with cerebral infarction (CCI), comparative research was made on 26 cases undergoing regional cerebral perfusion (rCP) image between SPECT imaging and CT scanning. The results showed that the rCP in the infarct and its distant area was decreased. The positive rate of SPECT and CT were 92.3% (24/26) and 84.5% (22/26) respectively. The difference was not significant (P = 0.67, P>0.05). But, the positive rate of SPECT image 2 days after onset in 9 CCI was 100% (9/9), significantly higher than 55.6% (5/9) in CT scanning (P = 0.04, P<0.05). These findings suggested that the SPECT imaging is a sensitive method for the early diagnosis of CCI, and also helpful for observation of the therapeutic effect and evaluation of the prognosis

  2. Diagnostic role of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for early and atypical bone metastases.

    Science.gov (United States)

    Chen, Xiao-Liang; Li, Qian; Cao, Lin; Jiang, Shi-Xi

    2014-01-01

    The bone metastasis appeared early before the bone imaging for most of the above patients. (99)Tc(m)-MDP ((99)Tc(m) marked methylene diphosphonate) bone imaging could diagnosis the bone metastasis with highly sensitivity, but with lower specificity. The aim of this study is to explore the diagnostic value of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for the early period atypical bone metastases. 15 to 30 mCi (99)Tc(m)-MDP was intravenously injected to the 34 malignant patients diagnosed as doubtful early bone metastases. SPECT, CT and SPECT/CT images were captured and analyzed consequently. For the patients diagnosed as early period atypical bone metastases by SPECT/CT, combining the SPECT/CT and MRI together as the SPECT/MRI integrated image. The obtained SPECT/MRI image was analyzed and compared with the pathogenic results of patients. The results indicated that 34 early period doubtful metastatic focus, including 34 SPECT positive focus, 17 focus without special changes by using CT method, 11 bone metastases focus by using SPECT/CT method, 23 doubtful bone metastases focus, 8 doubtful bone metastases focus, 14 doubtful bone metastases focus and 2 focus without clear image. Totally, SPECT/CT combined with SPECT/MRI method diagnosed 30 bone metastatic focus and 4 doubtfully metastatic focus. In conclusion, (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging shows a higher diagnostic value for the early period bone metastases, which also enhances the diagnostic accuracy rate.

  3. Brain imaging during seizure: ictal brain SPECT

    International Nuclear Information System (INIS)

    Kottamasu, Sambasiva Rao

    1997-01-01

    The role of single photon computed tomography (SPECT) in presurgical localization of medically intractable complex partial epilepsy (CPE) in children is reviewed. 99m Technetium neurolite, a newer lipophylic agent with a high first pass brain extraction and little or no redistribution is injected during a seizure, while the child is monitored with a video recording and continuous EEG and SPECT imaging is performed in the next 1-3 hours with the images representing regional cerebral profusion at the time of injection. On SPECT studies performed with radiopharmaceutical injected during a seizure, ictal focus is generally hypervascular. Other findings on ictal brain SPECT include hypoperfusion of adjacent cerebral cortex and white matter, hyperperfusion of contralateral motor cortex, hyperperfusion of ipsilateral basal ganglia and thalamus, brain stem and contralateral cerebellum. Ictal brain SPECT is non-invasive, cost effective and highly sensitive for localization of epileptic focus in patients with intractable CPE. (author)

  4. Computer interpretation of thallium SPECT studies based on neural network analysis

    Science.gov (United States)

    Wang, David C.; Karvelis, K. C.

    1991-06-01

    A class of artificial intelligence (Al) programs known as neural networks are well suited to pattern recognition. A neural network is trained rather than programmed to recognize patterns. This differs from "expert system" Al programs in that it is not following an extensive set of rules determined by the programmer, but rather bases its decision on a gestalt interpretation of the image. The "bullseye" images from cardiac stress thallium tests performed on 50 male patients, as well as several simulated images were used to train the network. The network was able to accurately classify all patients in the training set. The network was then tested against 50 unknown patients and was able to correctly categorize 77% of the areas of ischemia and 92% of the areas of infarction. While not yet matching the ability of a trained physician, the neural network shows great promise in this area and has potential application in other areas of medical imaging.

  5. Computer interpretation of thallium SPECT studies based on neural network analysis

    International Nuclear Information System (INIS)

    Wang, D.C.; Karvelis, K.C.

    1991-01-01

    This paper reports that a class of artificial intelligence (AI) programs known as neural-networks are well suited to pattern recognition. A neural network is trained rather than programmed to recognize patterns. This differs from expert system AI programs in that it is not following an extensive set of rules determined by the programmer, but rather bases its decision on a gestalt interpretation of the image. The bullseye images from cardiac stress thallium tests performed on 50 male patients, as well as several simulated images were used to train the network. The network was able to accurately classify all patients in the training set. The network was then tested against 50 unknown patients and was able to correctly categorize 77% of the areas of ischemia and 92% of the areas of infarction. While not yet matching the ability of the trained physician, the neural network shows great promise in this area and has potential application in other areas of medical imaging

  6. A serial changes of thallium-201 myocardial images in a patient with nontransmural myocardial infarction

    International Nuclear Information System (INIS)

    Tanaka, Takeshi; Itoh, Yukiyoshi; Takayama, Yasuo

    1986-01-01

    A 66 year old man had suffered from inferior myocardial infarction one year ago and then suffered from effort angina. Recently rest angina attack frequently occurred and he was admitted because of angina attack refractory to TNG. The patient was diagnosed as broad nontransmural infarction. A serial thallium-201 myocardial imagings at rest and thallium-201 lung uptake imagings were performed and some interesting findings were obtained as followings. Myocardial imagings on 3rd day after admission showed no significant deffect, however EF was 34 %. Immediately after severe ischemic attack marked defect was noted at posterolateral region and ECG showed prominent precordial ST depression without accompanying significant ST change in II, III, aVF. On 3rd day after severe attack under hemodynamically and electrocardiographically stable state posterolateral defect improved, though still persisted. EF was 28 %. On 3rd day postop no marked defects were noted in myocardial imagings, so posterolateral defect at rest after severe ischemic attack was proved to be transient defect. In this case thallium-201 lung uptake was not noted before attack. Immediately after severe attack thallium lung uptake increased and maximal uptake was noted at basal zone of lung, however in chest X-P typical butterfly shadow was noted at upper zone of lung. On 3rd day after severe attack hemodynamics improved and butterfly shadow ceased, though thallium lung uptake increased and noted at upper zone of lung. After operation thallium lung uptake improved. (J.P.N.)

  7. A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

    Science.gov (United States)

    Sciammarella, Maria; Shrestha, Uttam M; Seo, Youngho; Gullberg, Grant T; Botvinick, Elias H

    2017-08-03

    SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of 99m Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image

  8. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  9. Resting technetium-99m methoxyisobutylisonitrile cardiac imaging in chronic coronary artery disease: comparison with rest-redistribution thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Cuocolo, A.; Maurea, S.; Pace, L.; Nicolai, E.; Nappi, A.; Imbriaco, M.; Trimarco, B.; Salvatore, M.

    1993-01-01

    We studied 19 patients with angiographically proven coronary artery disease and left ventricular dysfunction (ejection fraction 33%±8%) by resting technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) and rest-redistribution thallium-201 cardiac imaging. Thallium and 99m Tc-MIBI studies were visually analysed. Of 285 segments, 203 (71%) had normal thallium uptake, 48 (17%) showed reversible thallium defects and 34 (12%) showed irreversible thallium defects. Of these 34 irreversible thallium defects, 19 (56%) were moderate and 15 (44%) were severe. Of the corresponding 285 segments, 200 (70%) had normal 99m Tc-MIBI uptake, while 37 (13%) showed moderate and 48 (17%) showed severe reduction of MIBI uptake. Myocardial segmental agreement for regional uptake score between initial thallium and resting 99m Tc-MIBI images was 90% (κ=0.78). Segmental agreement between delayed thallium and resting 99m Tc-MIBI images was 77% (κ=0.44). In particular, in 26 (9%) segments 99m Tc-MIBI uptake was severely reduced while delayed thallium uptake was normal or only moderately reduced. These data suggest that although rest-redistribution thallium and resting 99m Tc-MIBI cardiac imaging provide concordant results in the majority of myocardial segments, some segments with severely reduced resting 99m Tc-MIBI uptake may contain viable but hypoperfused myocardium. Thus, conclusions on myocardial viability based on 99m Tc-MIBI uptake should be made with caution in chronic coronary artery disease. (orig.)

  10. Assessment of viability by quantitative evaluation of 24h-redistribution in 201-thallium myocardial scintigraphy (SPECT): A comparative study versus clinical follow-up after revascularisation

    International Nuclear Information System (INIS)

    Stirner, H.; Spreng, M.; Picker, D.; Pfafferott, C.

    1992-01-01

    Results of regional quantitative assessment of 24h-redistribution in routinely performed Thallium myocardial scintigraphy (SPECT) were compared to findings of coronary angiography/ventriculography and/or echocardiography as well as clinical status 6 months after revascularisation in up to now 34 patients. In respect of positive and negative predictive values evaluation of 24h-redistribution behaves best (81/100%) compared to perfusion and 3h-redistribution alone. Performing an additional 24h-study gives a gain of at least 80% of diagnostic information. (orig.) [de

  11. Brain Perfusion SPECT Imaging in Sturge - Weber Syndrome : Comparison with MR Imaging

    International Nuclear Information System (INIS)

    Ryu, Jin Sook; Choi, Yun Young; Moon, Dae Hyuk; Yang, Seoung Oh; Ko, Tae Sung; Yoo, Shi Joon; Lee, Hee Kyung

    1996-01-01

    The purpose of this study was evaluate the characteristic perfusion changes in patients with Sturge-Weber syndrome by comparison of the findings of brain MR images and perfusion SPECT images. 99m Tc-HMPAO or 99m Tc-ECD interictal brain SPECTs were performed on 5 pediatric patients with Struge-Weber syndrome within 2 weeks after MR imaging. Brain SPECTs of three patients without calcification showed diminished perfusion in the affected area on MR image. A 3 month-old patient without brain atrophy or calcification demonstrated paradoxical hyperperfusion in the affected hemisphere, and follow-up perfusion SPECT revealed decreased perfusion in the same area. The other patient with advanced calcified lesion and atrophy on MR image showed diffusely decreased perfusion in the affected hemisphere, but a focal area of increased perfusion was also noted in the ipsilateral temporal lobe on SPECT. In conclusion, brain perfusion of the affected area of Sturge-Weber syndrome patients was usually diminished, but early or advanced patients may show paradoxical diffuse or focal hyperperfusion in the affected hemisphere. Further studies are needed for better understanding of these perfusion changes and pathophysiology of Struge-Weber syndrome.

  12. Volume and planar gated cardiac magnetic resonance imaging: a correlative study of normal anatomy with Thallium-201 SPECT and cadaver sections

    International Nuclear Information System (INIS)

    Go, R.T.; MacIntyre, W.J.; Yeung, H.N.

    1984-01-01

    Magnetic resonance (MR) gated cardiac imaging was performed in ten subjects using a prototype 0.15-T resistive magnet imaging system. Volume and planar imaging techniques utilizing saturation recovery, proton TI-weighted relaxation time pulse sequences produced images of the heart and great vessels with exquisite anatomic detail that showed excellent correlation with cadaver sections of the heart. The left ventricular myocardial segments also showed excellent correlation with cadaver sections of the heart. The left ventricular myocardial segments also showed excellent correlation with the thallium-201 cardiac single photon emission computed tomography images. Volume acquisition allowed postprocessing selection of tomographic sections in various orientations to optimize visualization of a particular structure of interest. The excellent spatial and contrast resolution afforded by MR volume imaging, which does not involve the use of ionizing radiation and iodinated contrast material, should assure it a significant role in the diagnostic assessment of the cardiovascular system

  13. Attenuation correction of myocardial SPECT images with X-ray CT. Effects of registration errors between X-ray CT and SPECT

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Murase, Kenya; Mochizuki, Teruhito; Motomura, Nobutoku

    2002-01-01

    Attenuation correction with an X-ray CT image is a new method to correct attenuation on SPECT imaging, but the effect of the registration errors between CT and SPECT images is unclear. In this study, we investigated the effects of the registration errors on myocardial SPECT, analyzing data from a phantom and a human volunteer. Registerion (fusion) of the X-ray CT and SPECT images was done with standard packaged software in three dimensional fashion, by using linked transaxial, coronal and sagittal images. In the phantom study, and X-ray CT image was shifted 1 to 3 pixels on the x, y and z axes, and rotated 6 degrees clockwise. Attenuation correction maps generated from each misaligned X-ray CT image were used to reconstruct misaligned SPECT images of the phantom filled with 201 Tl. In a human volunteer, X-ray CT was acquired in different conditions (during inspiration vs. expiration). CT values were transferred to an attenuation constant by using straight lines; an attenuation constant of 0/cm in the air (CT value=-1,000 HU) and that of 0.150/cm in water (CT value=0 HU). For comparison, attenuation correction with transmission CT (TCT) data and an external γ-ray source ( 99m Tc) was also applied to reconstruct SPECT images. Simulated breast attenuation with a breast attachment, and inferior wall attenuation were properly corrected by means of the attenuation correction map generated from X-ray CT. As pixel shift increased, deviation of the SPECT images increased in misaligned images in the phantom study. In the human study, SPECT images were affected by the scan conditions of the X-ray CT. Attenuation correction of myocardial SPECT with an X-ray CT image is a simple and potentially beneficial method for clinical use, but accurate registration of the X-ray CT to SPECT image is essential for satisfactory attenuation correction. (author)

  14. Skeletal scintigraphy and SPECT/CT in orthopedic imaging; Knochenszintigrafie und SPECT/CT bei orthopaedischen Fragestellungen

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, B.; Walter, M.; Krause, T. [Inselspital Bern (Switzerland). Universitaetsklinik fuer Nuklearmedizin

    2011-03-15

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  15. SPECT-T1-201 cardiac imaging

    International Nuclear Information System (INIS)

    Berman, D.S.

    1986-01-01

    Topics of discussion include: limitations of planar thallium-201 imaging; tomographic acquisition protocol; quantitative analysis involving slice selection, circumferential profile generation, comparison to normal limits and polar display of results; sensitivity and specificity; sources of error involving patient motion and upward creep; and clinical applications

  16. Myocardial perfusion SPECT imaging in patients with myocardial bridging

    International Nuclear Information System (INIS)

    Fang Wei; Qiu Hong; Yang Weixian; Wang Feng; He Zuoxiang

    2008-01-01

    Objective: Stress myocardial perfusion SPECT imaging was used to assess myocardial ischemia in patients with myocardial bridging. Methods: Ninety-six patients with myocardial bridging of the left anterior descending artery documented by coronary angiography were included in this study. All under- went exercise or pharmacological stress myocardial perfusion SPECT assessing myocardial ischemia. None had prior myocardial infarction. One year follow-up by telephone interview was performed in all patients. Results The mean stenotic severity of systolic phase on angiography was (65 ± 19)%. In the SPECT study, 20 of 96 (20.8%) patients showed abnormal perfusion. This percentage was significantly higher than that of stress electrocardiogram (ECG). The higher positive rate of SPECT perfusion images was showed in the group of patients with severe systolic narrowing (≥75%) than that with mild-to-moderate systolic narrowing (50% vs 6.3%, P<0.001). The prevalence of abnormal image was significantly higher in ELDERLY PEOPLE; patients with STT change on rest ECG than in those with normal rest ECG (54.2% vs 9.7%, P<0.001). During follow-up, one patient with abnormal SPECT perfusion image sustained angina and accepted percutaneous coronary intervention, and no cardiac event occurred in patients with normal images. Conclusions: Stress myocardial perfusion SPECT imaging can be used effectively for assessing myocardial ischemia and has potential prognostic value for patients with myocardial bridging. (authors)

  17. Evaluation of Tl-201 SPECT imaging findings in prostate cancer

    Directory of Open Access Journals (Sweden)

    Sinem Ozyurt

    2015-07-01

    Full Text Available Objectives: To compare with histopathological findings the findings of prostate cancer imaging by SPECT method using Tl-201 as a tumor seeking agent. Methods: The study comprised 59 patients (age range 51-79 years, mean age 65.3 ± 6.8 years who were planned to have transrectal ultrasonography (TRUS-guided biopsies due to suspicion of prostate cancer between April 2011 and September 2011. Early planar, late planar and SPECT images were obtained for all patients. Scintigraphic evaluation was made in relation to uptake presence and patterns in the visual assessment and to Tumor/Background (T/Bg ratios for both planar and SPECT images in the quantitative assessment. Histopathological findings were compatible with benign etiology in 36 (61% patients and malign etiology in 23 (39% patients. Additionally, comparisons were made to evaluate the relationships between uptake patterns,total PSA values and Gleason scores. Results: A statistically significant difference was found between the benign and malignant groups in terms of uptake in planar and SPECT images and T/Bg ratios and PSA values. No statistically significant difference was found between uptake patterns of planar and SPECT images and Gleason scores in the malignant group. Conclusions: SPECT images were superior to planar images in the comparative assessment. Tl-201 SPECT imaging can provide an additional contribution to clinical practice in the diagnosis of prostate cancer and it can be used in selected patients.

  18. Skeletal scintigraphy and SPECT/CT in orthopedic imaging

    International Nuclear Information System (INIS)

    Klaeser, B.; Walter, M.; Krause, T.

    2011-01-01

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  19. Thallium-201 myocardial imaging in evaluation of asymptomatic individuals with ischaemic ST segment depression on exercise electrocardiogram

    International Nuclear Information System (INIS)

    Caralis, D.G.; Bailey, I.; Kennedy, H.L.; Pitt, B.

    1979-01-01

    This study showed that asymptomatic adults with normal physical examination, normal resting electrocardiogram, and normal routine laboratory evaluation who had a positive exercise electrocardiogram and abnormal exercise thallium-201 myocardial image had a very high probability of angiographically significant coronary artery disease. If, on the other hand, the exercise electrocardiogram was positive for 'ischaemic' ST segment changes, but the exercise thallium image was normal, the probability for coronary disease was low. The exercise electrocardiogram combined with thallium-201 myocardial image are safe non-invasive methods which can be performed on an out-patient basis. (author)

  20. Preclinical imaging characteristics and quantification of Platinum-195m SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Aalbersberg, E.A.; Wit-van der Veen, B.J. de; Vegt, E.; Vogel, Wouter V. [The Netherlands Cancer Institute (NKI-AVL), Department of Nuclear Medicine, Amsterdam (Netherlands); Zwaagstra, O.; Codee-van der Schilden, K. [Nuclear Research and Consultancy Group (NRG), Petten (Netherlands)

    2017-08-15

    In vivo biodistribution imaging of platinum-based compounds may allow better patient selection for treatment with chemo(radio)therapy. Radiolabeling with Platinum-195m ({sup 195m}Pt) allows SPECT imaging, without altering the chemical structure or biological activity of the compound. We have assessed the feasibility of {sup 195m}Pt SPECT imaging in mice, with the aim to determine the image quality and accuracy of quantification for current preclinical imaging equipment. Enriched (>96%) {sup 194}Pt was irradiated in the High Flux Reactor (HFR) in Petten, The Netherlands (NRG). A 0.05 M HCl {sup 195m}Pt-solution with a specific activity of 33 MBq/mg was obtained. Image quality was assessed for the NanoSPECT/CT (Bioscan Inc., Washington DC, USA) and U-SPECT{sup +}/CT (MILabs BV, Utrecht, the Netherlands) scanners. A radioactivity-filled rod phantom (rod diameter 0.85-1.7 mm) filled with 1 MBq {sup 195m}Pt was scanned with different acquisition durations (10-120 min). Four healthy mice were injected intravenously with 3-4 MBq {sup 195m}Pt. Mouse images were acquired with the NanoSPECT for 120 min at 0, 2, 4, or 24 h after injection. Organs were delineated to quantify {sup 195m}Pt concentrations. Immediately after scanning, the mice were sacrificed, and the platinum concentration was determined in organs using a gamma counter and graphite furnace - atomic absorption spectroscopy (GF-AAS) as reference standards. A 30-min acquisition of the phantom provided visually adequate image quality for both scanners. The smallest visible rods were 0.95 mm in diameter on the NanoSPECT and 0.85 mm in diameter on the U-SPECT{sup +}. The image quality in mice was visually adequate. Uptake was seen in the kidneys with excretion to the bladder, and in the liver, blood, and intestine. No uptake was seen in the brain. The Spearman correlation between SPECT and gamma counter was 0.92, between SPECT and GF-AAS it was 0.84, and between GF-AAS and gamma counter it was0.97 (all p < 0

  1. Evaluation of initial uptake and redistribution on stress thallium-201 myocardial perfusion images in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Watanabe, Yoshihiko; Tonooka, Ichiroh; Kanaya, Tohru; Tsuiki, Kai; Yasui, Shouji.

    1984-01-01

    Stress thallium-201 myocardial perfusion imaging was performed on 29 patients with previous myocardial infarction and 29 patients with angina pectoris at exercise to evaluate thallium-201 kinetics in ischemic heart disease. Four views of thallium-201 images (right anterior oblique, antero-posterior, left anterior oblique and left lateral views) were obtained at 5 min after treadmill exercise with administration of 2 mCi of thallium-201 chloride (initial image) and at 3 hours later (delayed image). Myocardial images were divided into 6 segments (anterior, lateral, inferior, posterior, apical and septal segments) and initial uptake (IU) and redistribution index (RDI, the ratio of the maximal washout rate to a washout rate in each segment) were calculated in order to assess the relations of thallium-201 kinetics to wall motion abnormality and coronary artery stenosis. In myocardial infarction, IU and RDI were decreased in proportion to the severity of wall motion abnormality and coronary artery stenosis. Contrarily, in angina pectoris, IU was decreased but RDI was increased proportionally to the severity of coronary arterial stenosis. In conclusion, IU and redistribution of thallium-201 were affected essentially by both the grade of coronary arterial stenosis and the amount of residual viable heart muscle in patients with ischemic myocardial disease. (author)

  2. Fusion of SPECT/TC images: Usefulness and benefits in degenerative spinal cord pathology

    International Nuclear Information System (INIS)

    Ocampo, Monica; Ucros, Gonzalo; Bermudez, Sonia; Morillo, Anibal; Rodriguez, Andres

    2005-01-01

    The objectives are to compare CT and SPECT bone scintigraphy evaluated independently with SPECT-CT fusion images in patients with known degenerative spinal pathology. To demonstrate the clinical usefulness of CT and SPECT fusion images. Materials and methods: Thirty-one patients with suspected degenerative spinal disease were evaluated with thin-slice, non-angled helical CT and bone scintigrams with single photon emission computed tomography (SPECT), both with multiplanar reconstructions within a 24-hour period After independent evaluation by a nuclear medicine specialist and a radiologist, multimodality image fusion software was used to merge the CT and SPECT studies and a final consensus interpretation of the combined images was obtained. Results: Thirty-two SPECT bone scintigraphy images, helical CT studies and SPECT-CT fusion images were obtained for 31 patients with degenerative spinal disease. The results of the bone scintigraphy and CT scans were in agreement in 17 pairs of studies (53.12%). In these studies image fusion did not provide additional information on the location or extension of the lesions. In 11 of the study pairs (34.2%), the information obtained was not in agreement between scintigraphy and CT studies: CT images demonstrated several abnormalities, whereas the SPECT images showed only one dominant lesion, or the SPECT images did not provide enough information for anatomical localization. In these cases image fusion helped establish the precise localization of the most clinically significant lesion, which matched the lesion with the greatest uptake. In 4 studies (12.5%) the CT and SPECT images were not in agreement: CT and SPECT images showed different information (normal scintigraphy, abnormal CT), thus leading to inconclusive fusion images. Conclusion: The use of CT-SPECT fusion images in degenerative spinal disease allows for the integration of anatomic detail with physiologic and functional information. CT-SPECT fusion improves the

  3. Usefulness of rest-redistribution on thallium myocardial scintigraphy in patients with acute myocardial infarction by SPECT; Analysis by bull's eye and unfolded map images

    Energy Technology Data Exchange (ETDEWEB)

    Tahara, Yorio; Taya, Makoto; Sasaki, Akira; Nishimura, Tooru; Shimoyama, Katsuya; Mizuno, Haruyoshi; Ono, Akifumi; Okada, Michio; Ishikawa, Kyozo (Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine)

    1990-01-01

    The purpose of this study was to clarify the clinical significance of rest-redistribution in myocardial scintigraphy (SPECT) in acute myocardial infarction (AMI). 30 patients with AMI within one week after the onset of attack were studied. SPECT images were obtained 10 min and 3hrs after injection of {sup 201}Tl. Bull's eye images and unfolded map images were prepared. A {sup 201}Tl uptake was studied at the infarct and non-infarct sites. Exercise SPECT and radionuclide angiography were performed in all patients one month after the onset of AMI, and the findings were compared with clinical and coronary angiographic (CAG) findings. Redistribution of Tl at rest was observed at the infarct sites in 9 of the 30 patients. Redistribution at rest was observed at the non-infarct sites in 8 patients. Redistribution at rest was observed during exercise SPECT one month after the onset of AMI in patients with redistribution at rest in the acute phase. In patients with redistribution at rest at the infarct site, left ventricular ejection fraction (EF) improved one month after the onset of AMI ({Delta}EF>5%), but it decreased slightly during exercise. Wall motion at the infarct site was not much impaired in patients who showed redistribution at rest at the infarct site. Angina pectoris and recurrence of myocardial infarction were observed more frequently on SPECT, but no characteristic findings were obtained on CAG in those with redistribution at rest. In conclusion, cardiac function and wall motion at the infarct site are better preserved in patients with redistribution of Tl at rest on SPECT in the acute stage of myocardial infarction, as compared with patients having fixed defects, but the EF decrease slightly during exercise and the frequency of post-infarction angina is greater in those patients. Resting SPECT in AMI is considered to provide useful information for predicting cardiac function and the clinical course following myocardial infarction. (author).

  4. Multimodality imaging: transfer and fusion of SPECT and MRI data

    International Nuclear Information System (INIS)

    Knesaurek, K.

    1994-01-01

    Image fusion is a technique which offers the best of both worlds. It unites the two basic types of medical images: functional body images(PET or SPECT scans), which provide physiological information, and structural images (CT or MRI), which provide an anatomic map of the body. Control-point based registration technique was developed and used. Tc-99m point sources were used as external markers in SPECT studies while, for MRI and CT imaging only anatomic landmarks were used as a control points. The MRI images were acquired on GE Signa 1.2 system and CT data on a GE 9800 scanner. SPECT studies were performed 1h after intravenous injection of the 740 MBq of the Tc-99m-HMPAO on the triple-headed TRIONIX gamma camera. B-spline and bilinear interpolation were used for the rotation, scaling and translation of the images. In the process of creation of a single composite image, in order to retain information from the individual images, MRI (or CT) image was scaled to one color range and a SPECT image to another. In some situations the MRI image was kept black-and-white while the SPECT image was pasted on top of it in 'opaque' mode. Most errors which propagate through the matching process are due to sample size, imperfection of the acquisition system, noise and interpolations used. Accuracy of the registration was investigated by SPECT-CT study performed on a phantom study. The results has shown that accuracy of the matching process is better, or at worse, equal to 2 mm. (author)

  5. Rest/exercise thallium myocardial perfusion imaging: a new and rapid technique to evaluate coronary artery disease

    International Nuclear Information System (INIS)

    Segall, G.M.; Zipkin, R.E.; Stanford Univ., CA

    1993-01-01

    Twenty-six patients underwent conventional exercise/4-h redistribution thallium myocardial perfusion imaging as well as rest/exercise imaging on different days. For the rest/exercise study, patients were inmaged 10 min after receiving 1 mCi thallium at rest. The resting study was immediately followed by symptom-limited treadmill exercise. Patients were injected with 2 mCi thallium at peak exercise and imaged 10 min later. The entire rest/exercise study was completed in 2 h. There was a high degree of correlation between the two studies. Of the 130 segments analysed, 84 were normal and 46 were abnormal by exercise/redistribution imaging whereas 88 were normal and 42 were abnormal by rest/exercise imaging. Among the 14 patients who had coronary arteriography, both exercise/redistribution and rest/exercise imaging correctly identified 23/35 segments as abnormal (sensitivity [pi003] 66% and 34/35 segments as normal (specificity=97%). Furthermore, abnormal segments were more likely to be reversible on the rest/exercise study. The results suggest that the accuracy of rest/exercise thallium imaging is equal to conventional exercise/redistribution imaging in the evaluation of coronary artery disease. The significant time economy and possible improvement in assessing myocardial viability are important potential advantages of this new technique. (Author)

  6. Sequential SPECT/CT imaging starting with stress SPECT in patients with left bundle branch block suspected for coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Engbers, Elsemiek M.; Mouden, Mohamed [Isala, Department of Cardiology, Zwolle (Netherlands); Isala, Department of Nuclear Medicine, Zwolle (Netherlands); Timmer, Jorik R.; Ottervanger, Jan Paul [Isala, Department of Cardiology, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala, Department of Nuclear Medicine, Zwolle (Netherlands)

    2017-01-15

    To investigate the impact of left bundle branch block (LBBB) on sequential single photon emission computed tomography (SPECT)/ CT imaging starting with stress-first SPECT. Consecutive symptomatic low- to intermediate-risk patients without a history of coronary artery disease (CAD) referred for SPECT/CT were included from an observational registry. If stress SPECT was abnormal, additional rest SPECT and, if feasible, coronary CT angiography (CCTA) were acquired. Of the 5,018 patients, 218 (4.3 %) demonstrated LBBB. Patients with LBBB were slightly older than patients without LBBB (65±12 vs. 61±11 years, p<0.001). Stress SPECT was more frequently abnormal in patients with LBBB (82 % vs. 46 %, p<0.001). After reviewing stress and rest images, SPECT was normal in 43 % of the patients with LBBB, compared to 77 % of the patients without LBBB (p<0.001). Sixty-four of the 124 patients with LBBB and abnormal stress-rest SPECT underwent CCTA (52 %), which could exclude obstructive CAD in 46 of the patients (72 %). Sequential SPECT/CT imaging starting with stress SPECT is not the optimal imaging protocol in patients with LBBB, as the majority of these patients have potentially false-positive stress SPECT. First-line testing using CCTA may be more appropriate in low- to intermediate-risk patients with LBBB. (orig.)

  7. Quantitative thallium-201 single-photon emission computed tomography during maximal pharmacologic coronary vasodilation with adenosine for assessing coronary artery disease

    International Nuclear Information System (INIS)

    Nishimura, S.; Mahmarian, J.J.; Boyce, T.M.; Verani, M.S.

    1991-01-01

    The diagnostic value of maximal pharmacologic coronary vasodilation with intravenously administered adenosine in conjunction with thallium-201 single-photon emission computed tomography (SPECT) for detection of coronary artery disease was investigated in 101 consecutive patients who had concomitant coronary arteriography. Tomographic images were assessed visually and from computer-quantified polar maps of the thallium-201 distribution. Significant coronary artery disease, defined as greater than 50% luminal diameter stenosis, was present in 70 patients. The sensitivity for detecting patients with coronary artery disease using quantitative analysis was 87% in the total group, 82% in patients without myocardial infarction and 96% in those with prior myocardial infarction; the specificity was 90%. The sensitivity for diagnosing coronary artery disease in patients without infarction with single-, double-and triple-vessel disease was 76%, 86% and 90%, respectively. All individual stenoses were identified in 68% of patients with double-vessel disease and in 65% of those with triple-vessel disease. The extent of the perfusion defects, as quantified by polar maps, was directly related to the extent of coronary artery disease. In conclusion, quantitative thallium-201 SPECT during adenosine infusion has high sensitivity and specificity for diagnosing the presence of coronary artery disease, localizing the anatomic site of coronary stenosis and identifying the majority of affected vascular regions in patients with multivessel involvement

  8. Filters in 2D and 3D Cardiac SPECT Image Processing

    Directory of Open Access Journals (Sweden)

    Maria Lyra

    2014-01-01

    Full Text Available Nuclear cardiac imaging is a noninvasive, sensitive method providing information on cardiac structure and physiology. Single photon emission tomography (SPECT evaluates myocardial perfusion, viability, and function and is widely used in clinical routine. The quality of the tomographic image is a key for accurate diagnosis. Image filtering, a mathematical processing, compensates for loss of detail in an image while reducing image noise, and it can improve the image resolution and limit the degradation of the image. SPECT images are then reconstructed, either by filter back projection (FBP analytical technique or iteratively, by algebraic methods. The aim of this study is to review filters in cardiac 2D, 3D, and 4D SPECT applications and how these affect the image quality mirroring the diagnostic accuracy of SPECT images. Several filters, including the Hanning, Butterworth, and Parzen filters, were evaluated in combination with the two reconstruction methods as well as with a specified MatLab program. Results showed that for both 3D and 4D cardiac SPECT the Butterworth filter, for different critical frequencies and orders, produced the best results. Between the two reconstruction methods, the iterative one might be more appropriate for cardiac SPECT, since it improves lesion detectability due to the significant improvement of image contrast.

  9. SPECT/CT imaging in general orthopedic practice.

    Science.gov (United States)

    Scharf, Stephen

    2009-09-01

    The availability of hybrid devices that combine the latest single-photon emission computed tomography (SPECT) imaging technology with multislice computed tomography (CT) scanning has allowed us to detect subtle, nonspecific abnormalities on bone scans and interpret them as specific focal areas of pathology. Abnormalities in the spine can be separated into those caused by pars fractures, facet joint arthritis, or osteophyte formation on vertebral bodies. Compression fractures can be distinguished from severe degenerative disease, both of which can cause intense activity across the spine on either planar or SPECT imaging. Localizing activity in patients who have had spinal fusion can provide tremendous insight into the causes of therapeutic failures. Infections of the spine now can be diagnosed with gallium SPECT/CT, despite the fact that gallium has long been abandoned because of its failure to detect spine infection on either planar or SPECT imaging. Small focal abnormalities in the feet and ankles can be localized well enough to make specific orthopedic diagnoses on the basis of their location. Moreover, when radiographic imaging provides equivocal or inadequate information, SPECT/CT can provide a road map for further diagnostic studies and has been invaluable in planning surgery. Our ability to localize activity within a bone or at an articular surface has allowed us to distinguish between fractures and joint disease. Increased activity associated with congenital anomalies, such as tarsal coalition and Bertolotti's syndrome have allowed us to understand the pathophysiology of these conditions, to confirm them as the cause of the patient's symptoms, and to provide information that is useful in determining appropriate clinical management. As our experience broadens, SPECT/CT will undoubtedly become an important tool in the evaluation and management of a wider variety of orthopedic patients.

  10. Role of SPECT imaging in symptomatic posterior element lumbar stress injuries

    Directory of Open Access Journals (Sweden)

    Debnath U

    2005-01-01

    Full Text Available Background : Diagnosis of stress injuries of spine is very difficult with conventional radiography. Methods : In a observational study, 132 subjects were recruited (between 8 and 38 years of age, who had lumbar spondylolysis or posterior element stress injuries. All these patients underwent clinical examination followed by plain X-rays, planar bone scintigraphy and SPECT (single photon emission computerised tomography. SPECT scans can identify the posterior element lumbar stress injuries earlier than other imaging modalities. As the lesions evolve and the completed spondylolysis becomes chronic, the SPECT scans tend to revert to normal even though healing of the defect has not occurred. The aim of the study was to determine the time lag after which SPECT imaging tends to be negative. We divided the patients into two groups, one SPECT positive group and the other SPECT negative group. Pre treatment background variables such as age, gender, back pain in extension or flexion, sporting activities, time of onset of symptoms, Oswestry Disability Index (ODI were used in a univariate logistic regression model to find the strong predictors of positive SPECT imaging results. Determinants of positivity versus negativity of SPECT were identified by discriminant analysis using multivariate logistic regression. Results : Seventy nine patients had positive SPECT scans whereas 53 patients had negative SPECT scans. Bilateral increased uptake was more common than unilateral uptake. Increased uptake at the L5 lumbar spine was more common (70% in SPECT positive group. Low back pain in extension was significantly more common in SPECT positive subjects. Active sporting individuals had higher probability of having a positive SPECT scan. The mean time lag from the onset of low back pain to SPECT imaging was 7 months in SPECT positive group and 25 months in the SPECT negative group. Multivariate analysis predicted that there is a significant difference in positivity of

  11. Comparison of cone beam SPECT with conventional SPECT by means of cardiac-thorax phantom

    International Nuclear Information System (INIS)

    McGrath, M.A.; Manglos, S.H.

    1989-01-01

    Because of poor energy characteristics of Tl-201 used for myocardial perfusion imaging, the high sensitivity of cone-beam collimation is highly desirable. Using a cardiac-thorax phantom, the authors have compared single photon emission computed tomographic (SPECT) images obtained with a cone-beam collimator to those from a parallel hole collimator commonly used for thallium studies. A water-filled circular phantom with a cardiac insert was imaged. The myocardial shell was filled with Tl-201 (220 μCi). Two solid inserts within the myocardium simulated perfusion defects. The phantom ignores truncation effects in this preliminary experiment. For the authors' collimator, the resolution was designed to be similar to the authors' all-purpose, parallel-hole collimator at 10 cm. The focal length was 50 cm. The experimental protocol was chosen to be similar to their clinical protocol. A filtered back projection algorithm was used for cone-beam data. The same algorithm was used for the parallel-hole data, but with focal length set to infinity

  12. Usefulness of CT based SPECT Fusion Image in the lung Disease : Preliminary Study

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Lyu, Kwang Yeul; Kim, Tae Hyung; Shin, Ji Yun

    2012-01-01

    Recently, SPECT/CT system has been applied to many diseases, however, the application is not extensively applied at pulmonary disease. Especially, in case that, the pulmonary embolisms suspect at the CT images, SPECT is performed. For the accurate diagnosis, SPECT/CT tests are subsequently undergoing. However, without SPECT/CT, there are some limitations to apply these procedures. With SPECT/CT, although, most of the examination performed after CT. Moreover, such a test procedures generate unnecessary dual irradiation problem to the patient. In this study, we evaluated the amount of unnecessary irradiation, and the usefulness of fusion images of pulmonary disease, which independently acquired from SPECT and CT. Using NEMA PhantomTM (NU2-2001), SPECT and CT scan were performed for fusion images. From June 2011 to September 2010, 10 patients who didn't have other personal history, except lung disease were selected (male: 7, female: 3, mean age: 65.3±12.7). In both clinical patient and phantom data, the fusion images scored higher than SPECT and CT images. The fusion images, which is combined with pulmonary vessel images from CT and functional images from SPECT, can increase the detection possibility in detecting pulmonary embolism in the resin of lung parenchyma. It is sure that performing SPECT and CT in integral SPECT/CT system were better. However, we believe this protocol can give more informative data to have more accurate diagnosis in the hospital without integral SPECT/CT system.

  13. Clinical applications of SPECT/CT in imaging the extremities

    International Nuclear Information System (INIS)

    Huellner, Martin W.; Strobel, Klaus

    2014-01-01

    Today, SPECT/CT is increasingly used and available in the majority of larger nuclear medicine departments. Several applications of SPECT/CT as a supplement to or replacement for traditional conventional bone scintigraphy have been established in recent years. SPECT/CT of the upper and lower extremities is valuable in many conditions with abnormal bone turnover due to trauma, inflammation, infection, degeneration or tumour. SPECT/CT is often used in patients if conventional radiographs are insufficient, if MR image quality is impaired due to metal implants or in patients with contraindications to MR. In complex joints such as those in the foot and wrist, SPECT/CT provides exact anatomical correlation of pathological uptake. In many cases SPECT increases the sensitivity and CT the specificity of the study, increasing confidence in the final diagnosis compared to planar images alone. The CT protocol should be adapted to the clinical question and may vary from very low-dose (e.g. attenuation correction only), to low-dose for anatomical correlation, to normal-dose protocols enabling precise anatomical resolution. The aim of this review is to give an overview of SPECT/CT imaging of the extremities with a focus on the hand and wrist, knee and foot, and for evaluation of patients after joint arthroplasty. (orig.)

  14. Clinical applications of SPECT/CT in imaging the extremities

    Energy Technology Data Exchange (ETDEWEB)

    Huellner, Martin W. [University Hospital Zurich, Department of Medical Radiology, Division of Nuclear Medicine, Zurich (Switzerland); Strobel, Klaus [Lucerne Cantonal Hospital, Department of Nuclear Medicine and Radiology, Lucerne (Switzerland)

    2014-05-15

    Today, SPECT/CT is increasingly used and available in the majority of larger nuclear medicine departments. Several applications of SPECT/CT as a supplement to or replacement for traditional conventional bone scintigraphy have been established in recent years. SPECT/CT of the upper and lower extremities is valuable in many conditions with abnormal bone turnover due to trauma, inflammation, infection, degeneration or tumour. SPECT/CT is often used in patients if conventional radiographs are insufficient, if MR image quality is impaired due to metal implants or in patients with contraindications to MR. In complex joints such as those in the foot and wrist, SPECT/CT provides exact anatomical correlation of pathological uptake. In many cases SPECT increases the sensitivity and CT the specificity of the study, increasing confidence in the final diagnosis compared to planar images alone. The CT protocol should be adapted to the clinical question and may vary from very low-dose (e.g. attenuation correction only), to low-dose for anatomical correlation, to normal-dose protocols enabling precise anatomical resolution. The aim of this review is to give an overview of SPECT/CT imaging of the extremities with a focus on the hand and wrist, knee and foot, and for evaluation of patients after joint arthroplasty. (orig.)

  15. Monte Carlo simulation of PET and SPECT imaging of {sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiko, E-mail: takahsr@hs.med.kyushu-u.ac.jp; Sasaki, Masayuki [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Himuro, Kazuhiko; Yamashita, Yasuo; Komiya, Isao [Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Baba, Shingo [Department of Clinical Radiology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)

    2015-04-15

    Purpose: Yittrium-90 ({sup 90}Y) is traditionally thought of as a pure beta emitter, and is used in targeted radionuclide therapy, with imaging performed using bremsstrahlung single-photon emission computed tomography (SPECT). However, because {sup 90}Y also emits positrons through internal pair production with a very small branching ratio, positron emission tomography (PET) imaging is also available. Because of the insufficient image quality of {sup 90}Y bremsstrahlung SPECT, PET imaging has been suggested as an alternative. In this paper, the authors present the Monte Carlo-based simulation–reconstruction framework for {sup 90}Y to comprehensively analyze the PET and SPECT imaging techniques and to quantitatively consider the disadvantages associated with them. Methods: Our PET and SPECT simulation modules were developed using Monte Carlo simulation of Electrons and Photons (MCEP), developed by Dr. S. Uehara. PET code (MCEP-PET) generates a sinogram, and reconstructs the tomography image using a time-of-flight ordered subset expectation maximization (TOF-OSEM) algorithm with attenuation compensation. To evaluate MCEP-PET, simulated results of {sup 18}F PET imaging were compared with the experimental results. The results confirmed that MCEP-PET can simulate the experimental results very well. The SPECT code (MCEP-SPECT) models the collimator and NaI detector system, and generates the projection images and projection data. To save the computational time, the authors adopt the prerecorded {sup 90}Y bremsstrahlung photon data calculated by MCEP. The projection data are also reconstructed using the OSEM algorithm. The authors simulated PET and SPECT images of a water phantom containing six hot spheres filled with different concentrations of {sup 90}Y without background activity. The amount of activity was 163 MBq, with an acquisition time of 40 min. Results: The simulated {sup 90}Y-PET image accurately simulated the experimental results. PET image is visually

  16. Study of regional cerebral blood flow SPECT imaging for sudden sensorineural deafness

    International Nuclear Information System (INIS)

    Xie Changhui; Kui Xixiao; Xiong Qibin; Wen Hui; Xie Jiabiao

    1998-01-01

    Purpose: To study the clinical value of regional cerebral blood flow (rCBF) SPECT imaging for sudden sensorineural deafness (SSD). Methods: 10 normal persons, 19 conductive deafness and 31 SSD patients were examined by rCBF SPECT imaging, and compared with X CT at the same time. All SSD patients were followed up for 6∼12 months with repeated rCBF SPECT imaging. Results: 1) The radioactivity of diseased and normal horizontal temporal gyrus ratio (T/NT) in SSD patients was the lowest among three groups (P < 0.01). 2) The sensitivity (80.6%) and accurate rate (88.3%) of rCBF SPECT imaging in SSD patients were much higher than those of CT (3.2% and 50%, P < 0.01). 3) There was a significant correlation between degree of deafness and T/NT in SSD patients. 4) Good prognosis of SSD patients with normal rCBF SPECT was found. 5) The rCBF SPECT had close concordance between rCBF SPECT imaging and clinical prognosis (84.6%). Conclusions: rCBF SPECT imaging was superior to X CT in diagnosis of SSD and played an important clinical role

  17. Initial Investigation of preclinical integrated SPECT and MR imaging.

    Science.gov (United States)

    Hamamura, Mark J; Ha, Seunghoon; Roeck, Werner W; Wagenaar, Douglas J; Meier, Dirk; Patt, Bradley E; Nalcioglu, Orhan

    2010-02-01

    Single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high-spatial resolution anatomical information as well as complementary functional information. In this study, we utilized a dual modality SPECT/MRI (MRSPECT) system to investigate the integration of SPECT and MRI for improved image accuracy. The MRSPECT system consisted of a cadmium-zinc-telluride (CZT) nuclear radiation detector interfaced with a specialized radiofrequency (RF) coil that was placed within a whole-body 4 T MRI system. The importance of proper corrections for non-uniform detector sensitivity and Lorentz force effects was demonstrated. MRI data were utilized for attenuation correction (AC) of the nuclear projection data and optimized Wiener filtering of the SPECT reconstruction for improved image accuracy. Finally, simultaneous dual-imaging of a nude mouse was performed to demonstrated the utility of co-registration for accurate localization of a radioactive source.

  18. Clinical usefulness of hyperventilation-loaded SPECT in coronary artery disease

    International Nuclear Information System (INIS)

    Taya, Makoto

    1994-01-01

    The purpose of this study was twofold: (1) to assess the clinical usefulness of hyperventilation-loaded Tl-201 myocardial single photon emission computed tomography (HV-SPECT) in detecting coronary spasm; and (2) to correlate coronary spasm with ischemic heart diseases. A total of 138 patients were examined. They were divided into Group 1 of a total of 69 patients with chest pain at rest, consisting of 25 with vasospastic angina and 44 with atypical chest pain; Group 2 of 37 patients with angina pectoris; and Group 3 of 32 patients with myocardial infarction. In Group I, HV-SPECT was positive in 96% (24/25) for vasospastic angina and 50% (22/44) for atypical angina pectoris. When thallium defect scores 2 or more were interpreted as a decreased thallium uptake, Tl-201 HV-SPECT had a sensitivity of 72%, a specificity of 93%, and an accuracy of 85.6% in diagnosing vasospastic angina. In Group 2, HV-SPECT showed a significantly higher positive rate in patients with resting angina pectoris than those with effort angina pectoris (69% vs 22%). In Group 3, HV-SPECT was a positive rate of 53%. When Nifedipine was administered, the positive cases turned to be negative in 47%. HV-SPECT proved to be useful as a noninvasive method for diagnosing coronary spasm. Coronary spasm was suggested to be present in ischemic heart disease other than vasospastic angina and atypical chest pain. (N.K.)

  19. Comparison of arbutamine stress and treadmill exercise thallium-201 SPECT: Hemodynamics, safety profile and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Kiat, H.; Berman, D.S. [Cedars-Sinai Medical Centre, Los Angeles, California, LA (United States)

    1998-02-01

    Full text: Arbutamine (ARB), a new pharmacologic stress agent with enhanced chronotropic property compared to dobutamine, was compared with treadmill (TM) exercise testing (Ex) in a multicenter study using thallium-201 (Tl) SPECT. Of the total of 184 patients who underwent ARB, 69 also had TM stress and quantitative coronary angiography. Fifty-eight patients with a low pretest likelihood of CAD also underwent ARB study for evaluation of test specificity (normalcy rate). Tl scans were scored by a central laboratory using a 20 segment (seg)/scan visual analysis (5 point system: 0=normal, 4-absent uptake). Maximum heart rate (HR) by ARB and Ex was 122 vs 141 bpm (p<0.05). Mean %HR change from baseline was similar (79% vs 82%, respectively, p=ns). Maximum systolic BP for ARB and Ex was 173 vs 175 mmHg, and mean % change from baseline was 24% vs 28% (p=ns). Sensitivity for detecting CAD (270% stenosis) by ARB Tl was 94% and 97% by Ex Tl (p=ns). Stress Tl SPECT segmental agreement for presence of defect between ARB and Ex was 92% (kappa=0.8, p<0.001). Exact segmental stress Tl score (0-4 grading) agreement was 83 % (kappa=0.7, p<0.001). Among 346 segs with stress defects by both ARB and Ex defect reversibility agreement was 86% (kappa=0.7, p<0.001). The normalcy rate for ARB TI-SPECT among patients with a low likelihood of CAD was 90%. Adverse events were mostly mild (tremor: 23%, flushing: 10%, headache: 10%, paraesthesia: 8%, dizziness: 8%, hot flushes: 4%). Arrhythimia of clinical concern occurred in 8% (10/122) of ARB patients who had cardiac catheterisation and in 1.4% (1/69) of patients who had stress Tl. Of all 184 patients with ARB stress, ARB was discontinued due to arrhythmia in 7(5%) and 1 patient had IV Metoprolol for frequent ventricular couplets. Sustained arrhythmias were not observed

  20. Comparison of arbutamine stress and treadmill exercise thallium-201 SPECT: Hemodynamics, safety profile and diagnostic accuracy

    International Nuclear Information System (INIS)

    Kiat, H.; Berman, D.S.

    1998-01-01

    Full text: Arbutamine (ARB), a new pharmacologic stress agent with enhanced chronotropic property compared to dobutamine, was compared with treadmill (TM) exercise testing (Ex) in a multicenter study using thallium-201 (Tl) SPECT. Of the total of 184 patients who underwent ARB, 69 also had TM stress and quantitative coronary angiography. Fifty-eight patients with a low pretest likelihood of CAD also underwent ARB study for evaluation of test specificity (normalcy rate). Tl scans were scored by a central laboratory using a 20 segment (seg)/scan visual analysis (5 point system: 0=normal, 4-absent uptake). Maximum heart rate (HR) by ARB and Ex was 122 vs 141 bpm (p<0.05. Mean %HR change from baseline was similar (79% vs 82%, respectively, p=ns). Maximum systolic BP for ARB and Ex was 173 vs 175 mmHg, and mean % change from baseline was 24% vs 28% (p=ns). Sensitivity for detecting CAD (270% stenosis) by ARB Tl was 94% and 97% by Ex Tl (p=ns). Stress Tl SPECT segmental agreement for presence of defect between ARB and Ex was 92% (kappa=0.8, p<0.001). Exact segmental stress Tl score (0-4 grading) agreement was 83 % (kappa=0.7, p<0.001). Among 346 segs with stress defects by both ARB and Ex defect reversibility agreement was 86% (kappa=0.7, p<0.001). The normalcy rate for ARB TI-SPECT among patients with a low likelihood of CAD was 90%. Adverse events were mostly mild (tremor: 23%, flushing: 10%, headache: 10%, paraesthesia: 8%, dizziness: 8%, hot flushes: 4%). Arrhythimia of clinical concern occurred in 8% (10/122) of ARB patients who had cardiac catheterisation and in 1.4% (1/69) of patients who had stress Tl. Of all 184 patients with ARB stress, ARB was discontinued due to arrhythmia in 7(5%) and 1 patient had IV Metoprolol for frequent ventricular couplets. Sustained arrhythmias were not observed

  1. Novel SPECT Technologies and Approaches in Cardiac Imaging

    Directory of Open Access Journals (Sweden)

    Piotr Slomka

    2016-12-01

    Full Text Available Recent novel approaches in myocardial perfusion single photon emission CT (SPECT have been facilitated by new dedicated high-efficiency hardware with solid-state detectors and optimized collimators. New protocols include very low-dose (1 mSv stress-only, two-position imaging to mitigate attenuation artifacts, and simultaneous dual-isotope imaging. Attenuation correction can be performed by specialized low-dose systems or by previously obtained CT coronary calcium scans. Hybrid protocols using CT angiography have been proposed. Image quality improvements have been demonstrated by novel reconstructions and motion correction. Fast SPECT acquisition facilitates dynamic flow and early function measurements. Image processing algorithms have become automated with virtually unsupervised extraction of quantitative imaging variables. This automation facilitates integration with clinical variables derived by machine learning to predict patient outcome or diagnosis. In this review, we describe new imaging protocols made possible by the new hardware developments. We also discuss several novel software approaches for the quantification and interpretation of myocardial perfusion SPECT scans.

  2. Problems in the optimum display of SPECT images

    International Nuclear Information System (INIS)

    Fielding, S.L.

    1988-01-01

    The instrumentation, computer hardware and software, and the image display system are all very important in the production of diagnostically useful SPECT images. Acquisition and processing parameters are discussed which can affect the quality of SPECT images. Regular quality control of the gamma camera and computer is important to keep the artifacts due to instrumentation to a minimum. The choice of reconstruction method will depend on the statistics in the study. The paper has shown that for high count rate studies, a high pass filter can be used to enhance the reconstructions. For lower count rate studies, pre-filtering is useful and the data can be reconstructed into thicker slices to reduce the effect of image noise. Finally, the optimum display for the images must be chosen, so that the information contained in the SPECT data can be easily perceived by the clinician. (orig.) [de

  3. Evaluation of thallium-201 imaging in nontransmural ischemia and infarction

    International Nuclear Information System (INIS)

    Haidar, B.; Oldewurtel, H.A.; Moschos, C.B.; Lee, W.K.; Regan, T.J.

    1981-01-01

    To assess the validity of thallium-201 myocardial imaging in the diagnosis of nontransmural ischemia and infarction, the proximal left anterior descending coronary artery was partially occluded for 60 minutes with a balloon-tip catheter in intact anesthetized dogs in a basal state or during atrial pacing. In vivo scintigrams of myocardium were compared with those obtained in the isolated heart and in the incised ventricle spread flat. None of the animals with partial occlusion with or without pacing demonstrated abnormal scintiscans in vivo. Removal of background by isolating the heart increased positive images to 30%; positive images were associated with an isotope count ratio between ischemic and normal muscle of less than 0.67. Removal of superimposed nonischemic muscle in the heart enface increased image detection after pacing to 11 of 15. Since animals with subendocardial scar failed to demonstrate a cold area in vivo, unfavorable geometry as well as extent and degree of ischemia appear to be important. Thus, thallium radioactivity in superimposed and adjacent myocardium, as well as background, may limit the detection of nontransmural ischemia and scar

  4. Complexity and accuracy of image registration methods in SPECT-guided radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yin, L S; Duzenli, C; Moiseenko, V [Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC, V6T 1Z1 (Canada); Tang, L; Hamarneh, G [Computing Science, Simon Fraser University, 9400 TASC1, Burnaby, BC, V5A 1S6 (Canada); Gill, B [Medical Physics, Vancouver Cancer Centre, BC Cancer Agency, 600 West 10th Ave, Vancouver, BC, V5Z 4E6 (Canada); Celler, A; Shcherbinin, S [Department of Radiology, University of British Columbia, 828 West 10th Ave, Vancouver, BC, V5Z 1L8 (Canada); Fua, T F; Thompson, A; Sheehan, F [Radiation Oncology, Vancouver Cancer Centre, BC Cancer Agency, 600 West 10th Ave, Vancouver, BC, V5Z 4E6 (Canada); Liu, M [Radiation Oncology, Fraser Valley Cancer Centre, BC Cancer Agency, 13750 9th Ave, Surrey, BC, V3V 1Z2 (Canada)], E-mail: lyin@bccancer.bc.ca

    2010-01-07

    The use of functional imaging in radiotherapy treatment (RT) planning requires accurate co-registration of functional imaging scans to CT scans. We evaluated six methods of image registration for use in SPECT-guided radiotherapy treatment planning. Methods varied in complexity from 3D affine transform based on control points to diffeomorphic demons and level set non-rigid registration. Ten lung cancer patients underwent perfusion SPECT-scans prior to their radiotherapy. CT images from a hybrid SPECT/CT scanner were registered to a planning CT, and then the same transformation was applied to the SPECT images. According to registration evaluation measures computed based on the intensity difference between the registered CT images or based on target registration error, non-rigid registrations provided a higher degree of accuracy than rigid methods. However, due to the irregularities in some of the obtained deformation fields, warping the SPECT using these fields may result in unacceptable changes to the SPECT intensity distribution that would preclude use in RT planning. Moreover, the differences between intensity histograms in the original and registered SPECT image sets were the largest for diffeomorphic demons and level set methods. In conclusion, the use of intensity-based validation measures alone is not sufficient for SPECT/CT registration for RTTP. It was also found that the proper evaluation of image registration requires the use of several accuracy metrics.

  5. Exercise-induced thallium-201 myocardial perfusion defects in angina pectoris without significant coronary artery stenosis

    International Nuclear Information System (INIS)

    Nakazato, Masayasu; Maruoka, Yuji; Sunagawa, Osahiko; Kinjo, Kunihiko; Tomori, Masayuki; Fukiyama, Koshiro

    1990-01-01

    We performed exercise thallium-201 myocardial scintigraphy in 32 patients with angina pectoris to study the incidence of perfusion defects, who had no significant organic stenosis on coronary angiography. None of them had myocardial infarction or cardiomyopathy. Thallium-201 myocardial scintigraphy and 12-lead ECG recording were performed during supine bicycle ergometer exercise. Perfusion defects in thallium-201 scintigrams in SPECT images were assessed during visual analysis by two observers. In the coronary angiograms obtained during intravenous infusion of nitroglycerin, the luminal diameter of 75% stenosis or less in the AHA classification was regarded as an insignificant organic stenosis. Myocardial perfusion defects in the thallium-201 scintigrams were detected in eight (25%) of the 32 patients. Six of these eight patients had variant angina documented during spontaneous attacks with ST elevations in standard 12-lead ECGs. Perfusion defects were demonstrated at the inferior or infero-posterior regions in six patients, one of whom had concomitant anteroseptal defect. The defects were not always accompanied by chest pain. All but one patient demonstrating inferior or inferoposterior defects showed ST depression in leads II, III and aV F on their ECGs, corresponding to inferior wall ischemia. The exception was a case with right bundle branch block. Thus, 25% of the patients with angina pectoris, who had no evidence of significant organic stenosis on their coronary angiograms, exhibited exercise-induced perfusion defects in their thallium-201 scintigrams. Coronary spasms might have caused myocardial ischemia in these patients. (author)

  6. Development of a new statistical evaluation method for brain SPECT images

    International Nuclear Information System (INIS)

    Kawashima, Ryuta; Sato, Kazunori; Ito, Hiroshi; Koyama, Masamichi; Goto, Ryoui; Yoshioka, Seiro; Ono, Shuichi; Sato, Tachio; Fukuda, Hiroshi

    1996-01-01

    The purpose of this study was to develop a new statistical evaluation method for brain SPECT images. First, we made normal brain image databases using 99m Tc-ECD and SPECT in 10 normal subjects as described previously. Each SPECT images were globally normalized and anatomically standardized to the standard brain shape using Human Brain Atlas (HBA) of Roland et al. and each subject's X-CT. Then, mean and SD images were calculated voxel by voxel. For the next step, 99m Tc-ECD SPECT images of a patient were obtained, and global normalization and anatomical standardization were performed as the same way. Then, a statistical map was calculated as following voxel by voxel; (P-Mean)/SDx10+50, where P, mean and SD indicate voxel value of patient, mean and SD images of normal databases, respectively. We found this statistical map was helpful for clinical diagnosis of brain SPECT studies. (author)

  7. Pre-evaluation study in SPECT images using a phantom

    International Nuclear Information System (INIS)

    Rebelo, Marina de Sa; Furuie, Sergio Shiguemi; Abe, Rubens; Moura, Lincoln

    1996-01-01

    An alternative solution for the reconstruction of SPECT images using a Poisson Noise Model is presented. The proposed algorithm was applied on a real phantom and compared to the standard clinical procedures. Results have shown that the proposed method improves the quality of the SPECT images

  8. SPECT versus planar bone radionuclide imaging in the detection of spondylolysis

    International Nuclear Information System (INIS)

    Whitten, C.G.; El-Khoury, G.Y.; Chang, P.J.; Seabold, J.E.; Found, E.M.; Renfrew, D.L.

    1991-01-01

    This paper evaluates the relative performance and ease of interpretation of SPECT versus planar radionuclide bone imaging in the detection of spondylolysis. The authors studied all patients presenting with back pain suggestive of spondylolysis from November 1989 to January 1991 who underwent bone scanning; patients underwent both planar and SPECT imaging. The planar and SPECT images were randomly mixed and independently interpreted by four observers for presence or absence of spondylolysis and ease of interpretation for each scan. Receiver operating characteristic (ROC) and analysis of variance (ANOVA) were used. Of 72 patients, 19 had confirmed spondylolysis, and 53 did not. While ROC analysis showed that SPECT performed slightly better than planar imaging for all four observers, the difference was not statistically significant. ANOVA results suggest that planar imaging was significantly easier to use than SPECT and that ease of use was strongly correlated with the observer's confidence in the diagnosis

  9. Preoperative evaluation of malignancy of glioma by thallium-201 SPECT, proton MRS and 18F-fluorodeoxy-glucose PET

    International Nuclear Information System (INIS)

    Ito, Tamio; Nakagawara, Jyoji; Sasaki, Takehiko; Nakamura, Hirohiko; Tsukamoto, Eriko

    2005-01-01

    We studied preoperative malignancy evaluation of glioma by thallium-201 SPECT (T1-SPECT), proton MRS (MRS) and 18F-fluorodeoxy-glucose PET (FDG-PET). Twenty-seven patients with astrocytic tumors (diffuse astrocytoma (A): 8, anaplastic astrocytoma (AA): 10, glioblastoma (GB): 9) were retrospectively studied. FDG-PET was assessed as the visual metabolic grading scale (MG Scale) in 9 cases. The Tl index was expressed as the count rate of the tumor site to the count rate over the contralateral normal region in 25 cases. MRS was evaluated as the metabolite ratios of choline/creatine (Cho/Cr) and Cho/N-acetylaspartate (NAA), and as the presence of lactate and lipid metabolites in 23 cases. As the malignancy grade of the glioma rises, so too did the MG Scale of FDG-PET and Tl index (PET MG Scale (A: Grade (Gr). 1; 2 cases, Gr.2; 2 cases, AA: Gr.1; 1 case, Gr.2; 1 case, GB: Gr.2; 2 cases, Gr.3; 1 case), Tl index: A:129±0.22, AA: 1.97±0.44, GB: 342±1.38). Metabolite ratios of Cho/Cr and Cho/NAA in the high-grade gliomas were higher than those in the low-grade gliomas, however, those of GB were lower than those of AA, maybe due to difficulty in the spectroscopic voxel selection (Cho/Cr: A:1.86, AA: 2.96, GB: 2.73, Cho/NAA: A: 2.90, AA: 6.37, GB: 5.57). Both lactate and lipids presented in the high-grade glioma cases. Proliferative potential as measured by MIB-1 index mostly correlated with the Tl index significantly (p=0.0002). We were able to evaluate the malignancy grade of gliomas preoperatively by using FDG-PET, Tl-SPECT and MRS, however, we also need to understand the pitfalls of each of these examinations respectively (author)

  10. SPECT imaging of cardiac reporter gene expression in living rabbits

    International Nuclear Information System (INIS)

    Liu Ying; Lan Xiaoli; Zhang Liang; Wu Tao; Jiang Rifeng; Zhang Yongxue

    2009-01-01

    This work is to demonstrate feasibility of imaging the expression of herpes simplex virus 1-thymidine kinase (HSVI-tk) reporter gene in rabbits myocardium by using the reporter probe 131 I-2'-fluoro-2'-deoxy-l-β-D-arabinofuranosyl-5-iodouracil ( 131 I-FIAU) and SPECT. Rabbits of the study group received intramyocardial injection of Ad5-tk and control group received aseptic saline injection. Two sets of experiments were performed on the study group. Rabbits of the 1st set were injected with 131 I-FIAU 600 μCi at Day 2 after intramyocardial transfection of Ad5-tk in 1xl0 9 , 5x10 8 , 1x10 8 , 5x10 7 and 1x10 7 pfu, and heart SPECT imaging was done at different hours. Rabbits of the 2nd were transferred various titers of Ad5-tk (1x10 9 , 5x10 8 , 1x10 8 , 5x10 7 , 1x10 7 pfu) to determine the threshold and optimal viral titer needed for detection of gene expression. Two days later, 131 I-FIAU was injected and heart SPECT imaging was performed at 6, 24 and 48 h, before killing them for gamma counting of the hearts. Reverse transcription-polymerase chain reaction (RT-PCR) was used to verify the transferred HSVI-tk gene expression. Semi-quantitative analysis derived of region of interest (ROI) of SPECT images and RT-PCR images was performed and the relationship of SPECT images with ex vivo gamma counting and mRNA level were evaluated. SPECT images conformed 131 I-FIAU accumulation in rabbits injected with Ad5-tk in the anterolateral wall. The optimal images quality was obtained at 24-48 h for different viral titers. The highest radioactivity in the focal myocardium was seen at 6 h, and then declined with time. The threshold was 5x10 7 pfu of virus titer. The result could be set better in 1-5x10 8 pfu by SPECT analysis and gamma counting. ROI-derived semi-quantitative study on SPECT images correlated well with ex vivo gamma counting and mRNA levels from RT-PCR analysis. The HSVI-tk/ 131 I-FIAU reporter gene/reporter probe system is feasible for cardiac SPECT reporter

  11. Prognostic value of thallium-201 myocardial perfusion imaging in patients with unstable angina who respond to medical treatment

    International Nuclear Information System (INIS)

    Brown, K.A.

    1991-01-01

    Although the prognostic value of thallium-201 imaging is well established, its ability to risk stratify patients who present with unstable angina is unclear. Fifty-two consecutive patients admitted with unstable angina who responded to medical treatment and underwent stress thallium-201 imaging within 1 week of discharge were studied. Patients were followed up for 39 +/- 11 months. Cardiac events included cardiac death (n = 3), nonfatal myocardial infarction (n = 4) and admission for unstable angina or revascularization (n = 17). The ability of thallium-201 data (redistribution, fixed defects, normal) to predict cardiac events was compared with clinical data (age, gender, prior myocardial infarction, anginal syndrome, rest and stress electrocardiogram) and cardiac catheterization data using logistic regression. Thallium-201 redistribution was the only significant predictor of cardiac death or nonfatal myocardial infarction (p less than 0.05). The number of myocardial segments with thallium-201 redistribution (p less than 0.0005) and a history of prior myocardial infarction (p less than 0.05) were the only significant predictors of all cardiac events. Cardiac death or nonfatal myocardial infarction occurred more frequently in patients with thallium-201 redistribution (6 [26%] of 23) than in those without redistribution (1 [3%] of 29, p less than 0.05). Similarly, total cardiac events developed more frequently in patients with thallium-201 redistribution (p less than 0.001). Stress thallium-201 imaging has important prognostic value in patients admitted with unstable angina who respond to medical therapy and can identify subgroups at high versus low risk for future cardiac events

  12. Transient mitral regurgitation: An adjunctive sign of myocardial ischemia during dipyridamole-thallium imaging

    International Nuclear Information System (INIS)

    Lette, J.; Gagnon, A.; Lapointe, J.; Cerino, M.

    1989-01-01

    A patient developed transient exacerbation of a mitral insufficiency murmur and a reversible posterior wall perfusion defect during dipyridamole-thallium imaging. Coronary angiography showed significant stenoses of both the right and the circumflex coronary arteries that supply the posterior papillary muscle. Cardiac auscultation for transient mitral incompetence, a sign of reversible papillary muscle dysfunction, is a simple and practical adjunctive test for myocardial ischemia during dipyridamole-thallium imaging. It may confirm that an isolated reversible posterior wall myocardial perfusion defect is truly ischemic in nature as opposed to an artifact resulting from attenuation by the diaphragm

  13. Single-cell resolution mapping of neuronal damage in acute focal cerebral ischemia using thallium autometallography.

    Science.gov (United States)

    Stöber, Franziska; Baldauf, Kathrin; Ziabreva, Iryna; Harhausen, Denise; Zille, Marietta; Neubert, Jenni; Reymann, Klaus G; Scheich, Henning; Dirnagl, Ulrich; Schröder, Ulrich H; Wunder, Andreas; Goldschmidt, Jürgen

    2014-01-01

    Neuronal damage shortly after onset or after brief episodes of cerebral ischemia has remained difficult to assess with clinical and preclinical imaging techniques as well as with microscopical methods. We here show, in rodent models of middle cerebral artery occlusion (MCAO), that neuronal damage in acute focal cerebral ischemia can be mapped with single-cell resolution using thallium autometallography (TlAMG), a histochemical technique for the detection of the K(+)-probe thallium (Tl(+)) in the brain. We intravenously injected rats and mice with thallium diethyldithiocarbamate (TlDDC), a lipophilic chelate complex that releases Tl(+) after crossing the blood-brain barrier. We found, within the territories of the affected arteries, areas of markedly reduced neuronal Tl(+) uptake in all animals at all time points studied ranging from 15 minutes to 24 hours after MCAO. In large lesions at early time points, areas with neuronal and astrocytic Tl(+) uptake below thresholds of detection were surrounded by putative penumbral zones with preserved but diminished Tl(+) uptake. At 24 hours, the areas of reduced Tl(+)uptake matched with areas delineated by established markers of neuronal damage. The results suggest the use of (201)TlDDC for preclinical and clinical single-photon emission computed tomography (SPECT) imaging of hyperacute alterations in brain K(+) metabolism and prediction of tissue viability in cerebral ischemia.

  14. The usefulness of preoperative exercise stress myocardial single photon emission CT with thallium-201 to predict the responses to coronary revascularization

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Minamino, Takazoh; Katoh, Osamu; Higashino, Yorihiko.

    1989-01-01

    To evaluate the usefulness of preoperative exercise stress (Ex) myocardial single photon emission CT (SPECT) with thallium-201 to predict the responses to coronary revascularization (CRV), Ex-SPECT's were obtained in 42 patients with coronary artery disease (CAD). In 34 patients angioplasty was performed and in 18 patients coronary bypass surgery was undergone. Before and after CVR, Ex-SPECT's were obtained both at immediately after Ex (Initial) and 3 hours later (RD) by the rotating gamma camera. Initial images before CRV showed definite perfusion defects (+3) in 76 myocardial segments. Perfusion abnormalities at RD images were graded into (+3 to 0) by visual interpretation. '+3' indicated fixed defect and '0' indicated no perfusion abnormality. At RD images 17 segments showed fixed defect and 59 segments showed improved perfusion more than one grade. After CRV, all 59 segments with improved perfusion at RD images showed improvement of perfusion in comparison with initial images before CRV. Out of 17 segments with fixed defect before CRV, 14 segments showed perfusion defect with +3, while 3 segments showed improved perfusion after CRV. These 3 segments had ECG evidence of myocardial infarction. In these 3 segments, Ex-SPECT's before CRV showed abnormally low myocardial Tl washout rate (WOR) despite they indicated fixed defect visually. On the contrary, other 14 segments with fixed defect showed normal WOR before CRV. In conclusion, visually interpreted Ex-SPECT's before CRV predict the myocardial perfusion after CRV in most of cases. In a small number (especially infarction segments) Ex-SPECT's before CRV cannot predict the improvement of myocardial perfusion after CRV by visual inspection, but WOR abnormality before CRV is useful to prospect their results. (author)

  15. Radiotracers for SPECT imaging. Current scenario and future prospects

    International Nuclear Information System (INIS)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S.

    2012-01-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [ 123 I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [ 123 I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also makes them more

  16. Radiotracers for SPECT imaging. Current scenario and future prospects

    Energy Technology Data Exchange (ETDEWEB)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S. [GE Healthcare Medical Diagnostics, John F. Welch Technology Center, Bangalore (India).; Bhalla, R.; Pickett, R.; Luthra, S.K. [GE Healthcare Medical Diagnostics, The Grove Centre, Amersham (United Kingdom)

    2012-07-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [{sup 123}I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [{sup 123}I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also

  17. Prognostic value of intravenous dipyridamole thallium imaging in patients with diabetes mellitus considered for renal transplantation

    International Nuclear Information System (INIS)

    Camp, A.D.; Garvin, P.J.; Hoff, J.; Marsh, J.; Byers, S.L.; Chaitman, B.R.

    1990-01-01

    Patients with diabetes and end-stage renal failure are known to have a high risk for cardiac morbidity and mortality associated with renal transplantation. The most efficient method to determine preoperative cardiac risk has not been established. To determine the effectiveness of intravenous dipyridamole thallium imaging in predicting cardiac events, 40 diabetic renal transplant candidates were studied preoperatively in a prospective trial. The study group consisted of 40 patients whose average age was 42 years (range 27 to 64); 34 (85%) were hypertensive and 21 (53%) were cigarette smokers. Cardiac history included chest pain in 6 patients and prior myocardial infarction in 3 patients. Dipyridamole thallium imaging showed reversible defects in 9 patients, fixed defects in 8 patients and normal scans in 23 patients. Dipyridamole thallium imaging was performed using 0.56 mg/kg of dipyridamole infused intravenously over 4 minutes. Cardiac events occurred only in patients with reversible thallium defects, of which there were 6. Of these 6 patients, 3 had cardiac events before transplantation and 3 had them in the early postoperative phase (within 6 weeks of surgery). Of 21 patients who underwent renal transplantation, 3 had cardiac events within 6 weeks of transplantation. The average duration of follow-up was 11 months (range 1 to 21). Thus, dipyridamole thallium imaging is an effective method of identifying renal transplant candidates likely to develop cardiac complications. Routine coronary angiography may not be necessary to screen all renal transplant candidates for coronary artery disease before surgery

  18. Atlas of Skeletal SPECT/CT Clinical Images

    International Nuclear Information System (INIS)

    2016-01-01

    The atlas focuses specifically on single photon emission computed tomography/computed tomography (SPECT/CT) in musculoskeletal imaging, and thus illustrates the inherent advantages of the combination of the metabolic and anatomical component in a single procedure. In addition, the atlas provides information on the usefulness of several sets of specific indications. The publication, which serves more as a training tool rather than a textbook, will help to further integrate the SPECT and CT experience in clinical practice by presenting a series of typical cases with many different patterns of SPECT/CT seen in bone scintigraphy

  19. Thallium-201 myocardial perfusion imaging during transient coronary occlusion at the time of PTCA

    International Nuclear Information System (INIS)

    Nakagawa, Tatsuya; Sugihara, Hiroki; Inagaki, Suetsugu

    1989-01-01

    To evaluate myocardial perfusion during transient coronary arterial occlusion, thallium-201 was administered intravenously during percutaneous transluminall coronary angioplasty (PTCA) in 12 patients with effort angina, and the resulting perfusion images were compared with those of exercise stress obtained before PTCA. Thallium-201 was injected at the last inflation of an angioplastic baloon and occlusion was maintained for 60 to 90 sec. Three projections of planar images were obtained immediately after PTCA, using a portable gamma camera in an angiography room. These perfusion images obtained during PTCA and exercise were visually interpreted and compared. Myocardial perfusion defects due to the responsible vessel occlusion were observed at early imaging after PTCA, and were fully redistributed three hrs post injection. In 10 patients without angiographically imaged collateral vessels, there were no significatn differences in perfusion between images during PTCA and during exercise. Two patients whose collaterals were observed during coronary angiography before PTCA had higher perfusion scores during PTCA than during exercise. We concluded that intravenous injection of thallium-201 during PTCA is a useful means for assessing alteration of myocardial perfusion due to transient coronary occlusion without increasing the risk of angioplastic procedures, and that it provides more precise information about the jeopardized myocardium, perfused by antegrade blood flow. (author)

  20. Diagnostic accuracy of 201thallium-SPECT and 18F-FDG-PET in the clinical assessment of glioma recurrence

    International Nuclear Information System (INIS)

    Gomez-Rio, Manuel; Rodriguez-Fernandez, Antonio; Ramos-Font, Carlos; Lopez-Ramirez, Escarlata; Llamas-Elvira, Jose M.

    2008-01-01

    Reliable differential diagnosis between tumour recurrence and treatment-induced lesions is required to take advantage of new therapeutic approaches to recurrent gliomas. Structural imaging methods offer a high sensitivity but a low specificity, which might be improved by neurofunctional imaging. This study aimed to test the hypothesis that incorporation of 18-fluoro-deoxy-glucose positron emission tomography (FDG-PET) increases the accuracy of this differential diagnosis obtained with 201 Tl chloride-single-photon emission computed tomography ( 201 Tl-SPECT). Seventy-six patients (mean age 47.72 ± 16.19 years) under suspicion of glioma recurrence, 42% with low-grade and 58% with high-grade lesions, were studied by 201 Tl-SPECT and FDG-PET, reporting results under blinded conditions using visual analysis. Tumour was confirmed by histological confirmation (23 patients) or clinical and structural neuroimaging follow-up (mean of 2.6 years). This population had a high disease prevalence (72%). Globally, highest sensitivity was obtained using 201 Tl-SPECT assessed with MRI (96%) and highest specificity using FDG-PET + MRI (95%). FDG-PET appeared slightly better for confirming tumour recurrence, whereas 201 Tl-SPECT was superior for ruling out possible recurrence (disease present in 38% of FDG-PET negative explorations). In the high-grade subgroup, there were no false-positive examinations (specificity: 100%), but sensitivity differed among techniques ( 201 Tl-SPECT: 94%; 201 Tl-SPECT + MRI: 97%; FDG-PET + MRI: 83%). In the low-grade subgroup, 201 Tl-SPECT+ MRI showed highest sensitivity (95%) and lowest posttest negative probability (9%); FDG-PET + MRI offered highest specificity (92%) with a posttest negative probability of 35%. FDG-PET does not clearly improve the diagnostic accuracy of 201 Tl-SPECT, which appears to be a more appropriate examination for the diagnosis of possible brain tumour recurrence, especially for ruling it out. (orig.)

  1. Clinical course of cor pulmonale investigated after an interval of one year by thallium-201 myocardial SPECT scintigraphy

    International Nuclear Information System (INIS)

    Yamaoka, Shimpachi; Nishimura, Kouichi; Kuno, Kenshi; Yonekura, Yoshiharu; Koide, Harutoshi.

    1988-01-01

    Cor pulmonale was evaluated in 13 patients with chronic lung disease by thallium-201 myocardial SPECT scintigraphy together with pulmonary function tests and right heart catheterization. One year later, we performed this scintigraphy again to investigate the clinical course of the cor pulmonale. In 6 of 13 patients with respiratory failure (Pao 2 less than 60 Torr), a remarkable progression in cor pulmonale was noted after one year, despite outpatient oxygen therapy. If the patients were admitted because of acute exacerbation of respiratory failure, the cor pulmonale was found to have worsened. In contrast, patients with acute exacerbation due to respiratory infection or causes other than respiratory failure, showed little change in cor pulmonale. Although patients with a marked progression of cor pulmonale tended to have poor pulmonary function data and elevated pulmonary arterial pressure, the clinical course of cor pulmonale could not be predicted from the initial pulmonary function tests or right heart catheterization. (author)

  2. Dipyridamole thallium imaging for detecting cardiac involvement in patients with systemic sclerosis (scleroderma)

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Yoshio; Matsubara, Noboru; Tani, Akihiro; Morozumi, Takakazu; Hori, Masatsugu; Kitabatake, Akira; Kamada, Takenobu; Kimura, Kazufumi; Kozuka, Takahiro (Osaka Univ. (Japan). Faculty of Medicine)

    1990-02-01

    Dipyridamole thallium-201 imaging was carried out in 21 patients with progressive systemic sclerosis (PSS) to assess its value in detecting impaired myocardium and coronary microcirculation associated with PSS. Depending upon the degree of cardiac function, the patients were classified as having either ejection fraction of 50% or more (Group I, n=17) or less than 50% (Group II, n=4). In Group I, four patients had transient defect in which perfusion defects were seen on early images but not seen on delayed images; three had reverse redistribution in which defects were not seen on early images but seen on delayed images; and three had persistent defects which were seen on both early and delayed images. A decreased washout of thallium-201 was seen in 9 patients. In an analysis of both perfusion defects and washout rate, 13 patients (76%) in Group I were found to have abnormal findings. This suggests that disturbed coronary microcirculation or impaired myocardium may frequently develop even when EF is normal. All of the patients categorized as having a decreased cardiac function (Group II) had perfusion defect, suggesting the presence of myocardial fibrosis. In PSS, deterioration of cardiac function seemed to be associated with progression of myocardial fibrosis. Dipyridamole thallium imaging may be a sensitive method for detecting cardiac lesions in PSS. It also has the potential for detecting decreased coronary flow reserve or slightly impaired myocardium even without decreased EF. (N.K.).

  3. Onboard functional and molecular imaging: A design investigation for robotic multipinhole SPECT

    International Nuclear Information System (INIS)

    Bowsher, James; Giles, William; Yin, Fang-Fang; Yan, Susu; Roper, Justin

    2014-01-01

    Purpose: Onboard imaging—currently performed primarily by x-ray transmission modalities—is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single photon emission computed tomography (SPECT), are premier modalities for molecular imaging. The purpose of this study is to investigate a robotic multipinhole approach to onboard SPECT. Methods: Computer-aided design (CAD) studies were performed to assess the feasibility of maneuvering a robotic SPECT system about a patient in position for radiation therapy. In order to obtain fast, high-quality SPECT images, a 49-pinhole SPECT camera was designed which provides high sensitivity to photons emitted from an imaging region of interest. This multipinhole system was investigated by computer-simulation studies. Seventeen hot spots 10 and 7 mm in diameter were placed in the breast region of a supine female phantom. Hot spot activity concentration was six times that of background. For the 49-pinhole camera and a reference, more conventional, broad field-of-view (FOV) SPECT system, projection data were computer simulated for 4-min scans and SPECT images were reconstructed. Hot-spot localization was evaluated using a nonprewhitening forced-choice numerical observer. Results: The CAD simulation studies found that robots could maneuver SPECT cameras about patients in position for radiation therapy. In the imaging studies, most hot spots were apparent in the 49-pinhole images. Average localization errors for 10-mm- and 7-mm-diameter hot spots were 0.4 and 1.7 mm, respectively, for the 49-pinhole system, and 3.1 and 5.7 mm, respectively, for the reference broad-FOV system. Conclusions: A robot could maneuver a multipinhole SPECT system about a patient in position for radiation therapy. The system could provide onboard functional and molecular imaging with 4-min

  4. Onboard functional and molecular imaging: A design investigation for robotic multipinhole SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Bowsher, James, E-mail: james.bowsher@duke.edu; Giles, William; Yin, Fang-Fang [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27710 (United States); Yan, Susu [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27710 (United States); Roper, Justin [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710 (United States)

    2014-01-15

    Purpose: Onboard imaging—currently performed primarily by x-ray transmission modalities—is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single photon emission computed tomography (SPECT), are premier modalities for molecular imaging. The purpose of this study is to investigate a robotic multipinhole approach to onboard SPECT. Methods: Computer-aided design (CAD) studies were performed to assess the feasibility of maneuvering a robotic SPECT system about a patient in position for radiation therapy. In order to obtain fast, high-quality SPECT images, a 49-pinhole SPECT camera was designed which provides high sensitivity to photons emitted from an imaging region of interest. This multipinhole system was investigated by computer-simulation studies. Seventeen hot spots 10 and 7 mm in diameter were placed in the breast region of a supine female phantom. Hot spot activity concentration was six times that of background. For the 49-pinhole camera and a reference, more conventional, broad field-of-view (FOV) SPECT system, projection data were computer simulated for 4-min scans and SPECT images were reconstructed. Hot-spot localization was evaluated using a nonprewhitening forced-choice numerical observer. Results: The CAD simulation studies found that robots could maneuver SPECT cameras about patients in position for radiation therapy. In the imaging studies, most hot spots were apparent in the 49-pinhole images. Average localization errors for 10-mm- and 7-mm-diameter hot spots were 0.4 and 1.7 mm, respectively, for the 49-pinhole system, and 3.1 and 5.7 mm, respectively, for the reference broad-FOV system. Conclusions: A robot could maneuver a multipinhole SPECT system about a patient in position for radiation therapy. The system could provide onboard functional and molecular imaging with 4-min

  5. High resolution SPECT imaging for visualization of intratumoral heterogeneity using a SPECT/CT scanner dedicated for small animal imaging

    International Nuclear Information System (INIS)

    Umeda, Izumi O.; Tani, Kotaro; Tsuda, Keisuke

    2012-01-01

    Tumor interiors are never homogeneous and in vivo visualization of intratumoral heterogeneity would be an innovation that contributes to improved cancer therapy. But, conventional nuclear medicine tests have failed to visualize heterogeneity in vivo because of limited spatial resolution. Recently developed single photon emission computed tomographic (SPECT) scanners dedicated for small animal imaging are of interest due to their excellent spatial resolution of 111 In and simulations of actual small animal imaging. The optimal conditions obtained were validated by in vivo imaging of sarcoma 180-bearing mice. Larger number of counts must be obtained within limited acquisition time to visualize tumor heterogeneity in vivo in animal imaging, compared to cases that simply detect tumors. At an acquisition time of 30 min, better image quality was obtained with pinhole apertures diameter of 1.4 mm than of 1.0 mm. The obtained best spatial resolution was 1.3 mm, it was acceptable for our purpose, though a little worse than the best possible performance of the scanner (1.0 mm). Additionally, the reconstruction parameters, such as noise suppression, voxel size, and iteration/subset number, needed to be optimized under the limited conditions and were different from those found under the ideal condition. The minimal radioactivity concentration for visualization of heterogeneous tumor interiors was estimated to be as high as 0.2-0.5 MBq/mL. Liposomes containing 111 In met this requirement and were administered to tumor-bearing mice. SPECT imaging successfully showed heterogeneous 111 In distribution within the tumors in vivo with good spatial resolution. A threshold of 0.2 MBq/g for clear visualization of tumor heterogeneity was validated. Autoradiograms obtained ex vivo of excised tumors confirmed that the in vivo SPECT images accurately depicted the heterogeneous intratumoral accumulation of liposomes. Intratumoral heterogeneity was successfully visualized under the optimized

  6. Usefulness of Ga-67 citrate whole body imaging, chest spot imaging, and chest SPECT in sarcoidosis

    International Nuclear Information System (INIS)

    Ueno, Kyoichi; Nishi, Koichi; Namura, Masanobu; Kawashima, Yoshio; Kurumaya, Hiroshi

    1999-01-01

    To assess the sensitivity, and the relative role of Ga-67 whole body, chest spot imaging, and chest SPECT, we retrospectively studied 34 cases of sarcoidosis (24 biopsy proven, 10 clinically diagnosed) with Ga-67 (111 MBq), and compared the results of lung (25 cases), muscle (25 cases), skin (3 cases), and myocardial (2 cases) biopsies. Ga-67 chest SPECT (single photon emission CT) were done in 17 cases with Siemens MultiSPECT3. Ga-67 planar imaging visualized only 2 of 12 (16.7%) lung biopsy-positive cases, 5 of 12 (41.6%) muscle biopsy-positive cases, 2 of 3 (66.7%) skin biopsy-positive cases. However, Ga-67 imaging revealed the lesions in 1 of 9 (11.1%) of muscle biopsy-negative cases, in 2 of 3 (66.7%) of skin biopsy-negative cases, and in 1 of 2 myocardial biopsy-negative cases. Ga-67 chest SPECT visualized 14 hilar lymphadenopathy (LN), 3 supraclavicular LN, and 1 myocardial sarcoidosis. Although both SPECT, and planar spot imaging detected the lesions equally, the former showed them more clearly. Compared with various biopsies, the sensitivity of Ga-67 imaging was not so high. However, Ga-67 imaging is non-invasive, easy to perform the whole body imaging, and can detect the activity of the lesions. Ga-67 SPECT showed clear imaging of the hilar, mediastinal LN, and potentially fatal myocardial sarcoidosis. (author)

  7. Quantification of leg muscle perfusion using thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Oshima, M.; Akanabe, H.; Sakuma, S.; Yano, T.; Nishikimi, N.; Shionoya, S.

    1989-01-01

    The purpose of this study is to quantify leg muscle perfusion with 201 Tl single photon emission computed tomography (SPECT). Six normal controls and 21 patients with peripheral arterial disease underwent this examination. Thallium-201 leg SPECT of both stress and redistribution was performed using a dual-headed digital gamma camera. Each slice of transverse images was normalized with pixels and whole-body counts. In normal controls, the activity of posterior tibial muscle components was significantly higher than that of anterior tibial muscle components (p less than 0.001). In 14 components, where patients had insignificant lesions, profile curves were normal in 10 (71%). In 62 components, where patients had arteriographically significant lesions, stress profile curves were abnormal in 57 (92%) compared with normal controls. Approximately, in half (28/62) components which had significant lesions, profile curves showed redistribution after 3 hr compared with normal redistribution curves. In three patients who underwent successful bypass graftings, the activity of each muscle component returned to a normal range

  8. Brain SPECT in children; Explorations scintigraphiques en neurologie et psychiatrie de l`enfant

    Energy Technology Data Exchange (ETDEWEB)

    Guyot, M. [Hopital Pellegrin, 33 - Bordeaux (France); Baulieu, J.L. [Hopital Bretonneau, 37 - Tours (France)

    1996-12-31

    Brain SPECT in child involves specific trends regarding the patient cooperation, irradiation, resolution and especially interpretation because of the rapid scintigraphic modifications related to the brain maturation. In a general nuclear medicine department, child brain SPECT represents about 2 % of the activity. The choice indications are the perfusion children: thallium and MIBI in brain tumours, pharmacological and neuropsychological interventions. In the future, brain dedicated detectors and new radiopharmaceuticals will promote the development of brain SPECT in children. (author). 18 refs.

  9. The pacing stress test: thallium-201 myocardial imaging after atrial pacing. Diagnostic value in detecting coronary artery disease compared with exercise testing

    International Nuclear Information System (INIS)

    Heller, G.V.; Aroesty, J.M.; Parker, J.A.; McKay, R.G.; Silverman, K.J.; Als, A.V.; Come, P.C.; Kolodny, G.M.; Grossman, W.

    1984-01-01

    Many patients suspected of having coronary artery disease are unable to undergo adequate exercise testing. An alternate stress, pacing tachycardia, has been shown to produce electrocardiographic changes that are as sensitive and specific as those observed during exercise testing. To compare thallium-201 imaging after atrial pacing stress with thallium imaging after exercise stress, 22 patients undergoing cardiac catheterization were studied with both standard exercise thallium imaging and pacing thallium imaging. Positive ischemic electrocardiographic changes (greater than 1 mm ST segment depression) were noted in 11 of 16 patients with coronary artery disease during exercise, and in 15 of the 16 patients during atrial pacing. One of six patients with normal or trivial coronary artery disease had a positive electrocardiogram with each test. Exercise thallium imaging was positive in 13 of 16 patients with coronary artery disease compared with 15 of 16 patients during atrial pacing. Three of six patients without coronary artery disease had a positive scan with exercise testing, and two of these same patients developed a positive scan with atrial pacing. Of those patients with coronary artery disease and an abnormal scan, 85% showed redistribution with exercise testing compared with 87% during atrial pacing. Segment by segment comparison of thallium imaging after either atrial pacing or exercise showed that there was a good correlation of the location and severity of the thallium defects (r . 0.83, p . 0.0001, Spearman rank correlation). It is concluded that the location and presence of both fixed and transient thallium defects after atrial pacing are closely correlated with the findings after exercise testing

  10. Asymmetrically thickened posterior wall is associated with decline of ejection fraction after stress on adenosine stress/rest thallium-201 gated myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bom Sahn; Lee, Won Woo; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Kim, Sang Eun [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    2004-07-01

    LV parameters (LVEF. ESVI and EDVI) on adenosine stress/rest thallium-201 gated myocardial SPECT (gSPECT) are various from stress to rest. We investigated the reason why they were various in patients without coronary artery disease. Seventy-one patients(M:F=32:39, age 58.1{+-}9.7yrs), who underwent gSPECT and coronary angiography (CAG) due to chest pain or preoperative evaluation were included. CAG results were normal or insignificant. Exclusion criteria were atrial fibrillation, thyroid disease, primary cardiomyopathy, myocardial bridge, LBBB, MI, and valvular heart disease. Patients were calssified into 3 groups by EF difference ({delta}EF=rest-stress EF) on gSPECT : group1 ({delta}EF{>=}10), group2 (0 {<=}{delta}EF<10), and group3 ({delta}EF<0). LV parameters on gSPECT and thicknesses of IVS (interventricular septum) and LVPW (left ventricular posterior wall) on echocardiography were compared among the 3 groups. Myocardial perfusion status were normal or mild reversible/persistent perfusion defect in 76.1% (54/71). LVEFs at stress were not different among all 3 groups : 59.3{+-}8.54% in group 1 (61.3{+-}10.22% in group 2 and 64.8{+-}7.58% in group 3 (p>0.05). But LVEF at rest was smaller in group 3 (58.7{+-}8.38%) than the other groups (72.5{+-}8.77% in group1 and 66.7{+-}10.6% in group2) (p<0.01). EDVIs and ESVI at stress were larger than those at rest in all groups (p<0.05) except ESVI in group 3 (16.2{+-}6.21ml at stress and 17.5{+-}6.41ml at rest, p<0.01), and that was attributed to EF<0 in group 3. In echocardiographical analysis, group 3 had significantly increased wall thickness of LVPW (10.7{+-}1.2mm versus 9.4{+-}1.6mm, p=0.01) and decreased wall thickness ratio of IVS/LVPW (0.963{+-}0.102 versus 1.048{+-}0.104, p=0.035) than group 1. In patients without coronary artery disease, LVEF, EDVI and ESVI on gSPECT were various and decline of LVEF from stress to rest was caused by unnormalized ESVI . Asymmetrically thickened LVPW may play a crucial role and

  11. Compensation of Cross-Contamination in Simultaneous 201Tl/99mTc Myocardial Perfusion SPECT Imaging

    Directory of Open Access Journals (Sweden)

    Faraz Kalantari

    2009-12-01

    Full Text Available Introduction: It is a common protocol to use 201Tl for the rest and 99mTc for the stress cardiac SPECT imaging. Theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. However, a potential limitation is the cross-contamination of scattered photons from 99mTc and collimator X-rays into the 201Tl energy window. We used a middle energy window method to correct this cross-contamination. Material and Methods: Using NCAT, a typical software torso phantom was generated. An extremely thin line source of 99mTc activity was placed inside the cardiac region of the phantom and no activity in the other parts.  The SimSET Monte Carlo simulator was used to image the phantom in different energy windows. To find the relationship between projections in different energy windows, deconvolution theory was used. We investigated the ability of the suggested functions in three steps: Monte Carlo simulation, phantom experiment and clinical study. In the last step, SPECT images of eleven patients who had angiographic data were acquired in different energy windows. All of these images were compared by determining the contrast between a defect or left ventricle cavity and the myocardium. Results: We found a new 2D kernel which had an exponential pattern with a much higher center. This function was used for modeling 99mTc down scatter distribution from the middle window image. X-ray distribution in the 201Tl window was also modeled as the 99mTc photopeak image convolved by a Gaussian function. Significant improvements in the contrasts of the simultaneous dual 201Tl images were found in each step before and after reconstruction. In comparison with other similar methods, better results were acquired using our suggested functions. Conclusion: Our results showed contrast improvement in thallium images after correction, however, many other parameters should be evaluated for clinical approaches. There are many

  12. Is SPECT useful in imaging of abdominal inflammatory processes using 99mTc-HMPAO-WBCs?

    International Nuclear Information System (INIS)

    Smole, M.S.; Stantic, T.S.; Fettich, J.F.

    2002-01-01

    Aim: The aim of the study is to determine whether SPECT gives additional information in the assessment of inflammation of the abdominal region with labelled white blood cells as compared with usual planar imaging. Patients And Methods: SPECT and planar imaging was performed in 26 patients with suspected inflammatory process in the abdomen, within three hours after injection of autologous white blood cells labelled with 99m Tc HMPAO. Planar images where acquired as static spot images using high resolution low energy collimator on 256 x 256 matrix. SPECT was performed using the same collimator on 128 x 128 matrix in 128 projections. Filtered back projection was used for reconstruction and volume rendering was performed. Results: The lesions in the abdomen were classified as jejunum, colon ascendents, colon transversum, colon descendents, sigmoid, and lesions outside GIT. All lesions, which were seen on planar images, except one, were also seen on SPECT. Five equivocal lesions seen on planar images were reconfirmed as pathological on SPECT. Additionally SPECT revealed three lesions not seen on planar images. Fourteen lesions were seen by both imaging techniques. All together SPECT improved diagnostic accuracy of 99m Tc - HMPAO - WBC scintigraphy in 7/28 patients. Conclusion: more inflammatory lesions in the abdomen are revealed by SPECT and volume rendering, than by planar imaging equivocal lesions seen on planar images can be characterised as positive or negative by SPECT. SPECT artefacts can cause possible false positive results; therefore usual planar imaging cannot be omitted if SPECT is performed

  13. Clinical applications of SPECT/CT: New hybrid nuclear medicine imaging system

    International Nuclear Information System (INIS)

    2008-08-01

    Interest in multimodality imaging shows no sign of subsiding. New tracers are spreading out the spectrum of clinical applications and innovative technological solutions are preparing the way for yet more modality marriages: hybrid imaging. Single photon emission computed tomography (SPECT) has enabled the evaluation of disease processes based on functional and metabolic information of organs and cells. Integration of X ray computed tomography (CT) into SPECT has recently emerged as a brilliant diagnostic tool in medical imaging, where anatomical details may delineate functional and metabolic information. SPECT/CT has proven to be valuable in oncology. For example, in the case of a patient with metastatic thyroid cancer, neither SPECT nor CT alone could identify the site of malignancy. SPECT/CT, a hybrid image, precisely identified where the surgeon should operate. However SPECT/CT is not just advantageous in oncology. It may also be used as a one-stop-shop for various diseases. Clinical applications with SPECT/CT have started and expanded in developed countries. It has been reported that moving from SPECT alone to SPECT/CT could change diagnoses in 30% of cases. Large numbers of people could therefore benefit from this shift all over the world. This report presents an overview of clinical applications of SPECT/CT and a relevant source of information for nuclear medicine physicians, radiologists and clinical practitioners. This information may also be useful for decision making when allocating resources dedicated to the health care system, a critical issue that is especially important for the development of nuclear medicine in developing countries. In this regard, the IAEA may be heavily involved in the promotion of programmes aimed at the IAEA's coordinated research projects and Technical Cooperation projects

  14. Diagnosis and staging of breast cancer by SPECT images fused with CT images

    International Nuclear Information System (INIS)

    Li Yanjing; Zhu Qiaomei

    2007-01-01

    Objective: To evaluate the TNM staging value of 99mTc-MIBI scintimammotraphy with SPECT-CT images fusing for the diagnosis of breast cancer. Methods: 10 patients with breast cancer underwent scintimammography with 99mTc-MIBI, and SPECT images were fused with CT images. Images were compared with final diagnosis confirmed by histopathology. Results: Of the 19 breast cancer patients, one case of invasive ductal carcinoma showed false-negative. Among 18 cases of positive lesions, axillary metastases were involved in 10, supraclavicular nodes were also defined in 3, para-sternum nodes were involved in 2, 2 were missed and 1 cases without metastatic node. The axillary lymph nodes were divided into three levels with respect to their position relative to the pectoralis minor muscle by fused images. Conclusion: 99mTc-MIBI scintimammotraphy combined with SPECT-CT images fusing is of some clinical value in TNM staging of breast cancer. (authors)

  15. Imaging fusion (SPECT/CT) in degenerative disease of spine

    International Nuclear Information System (INIS)

    Bernal, P.; Ucros, G.; Bermudez, S.; Ocampo, M.

    2007-01-01

    Full text: Objective: To determine the utility of Fusion Imaging SPECT/CT in degenerative pathology of the spine and to establish the impact of the use of fusion imaging in spinal pain due to degenerative changes of the spine. Materials and methods: 44 Patients (M=21, F=23) average age of 63 years and with degenerative pathology of spine were sent to Diagnosis Imaging department in FSFB. Bone scintigraphy (SPECT), CT of spine (cervical: 30%, Lumbar 70%) and fusion imaging were performed in all of them. Bone scintigraphy was carried out in a gamma camera Siemens Diacam double head attached to ESOFT computer. The images were acquired in matrix 128 x 128, 20 seg/imag, 64 images. CT of spine was performed same day or two days after in Helycoidal Siemens somatom emotion CT. The fusion was done in a Dicom workstation in sagital, axial and coronal reconstruction. The findings were evaluated by 2 Nuclear Medicine physicians and 2 radiologists of the staff of FSFB in an independent way. Results: Bone scan (SPECT) and CT of 44 patients were evaluated. CT showed facet joint osteoarthrities in 27 (61.3%) patients, uncovertebral joint arthrosis in 7 (15.9%), bulging disc in 9(20.4%), spinal nucleus lesion in 7(15.9%), osteophytes in 9 (20.4%), spinal foraminal stenosis in 7 (15.9%), spondylolysis/spondylolisthesis in 4 (9%). Bone scan showed facet joint osteoarthrities in 29 (65.9%), uncovertebral joint arthrosis in 4 (9%), osteophytes in 9 (20.4%) and normal 3 (6.8%). The imaging fusion showed coincidence findings (main lesion in CT with high uptake in scintigraphy) in 34 patients (77.2%) and no coincidence in 10 (22.8%). In 15 (34.09%) patients the fusion provided additional information. The analysis of the findings of CT and SPECT showed similar results in most of the cases and the fusion didn't provide additional information but it allowed to confirm the findings but when the findings didn't match where the CT showed several findings and SPECT only one area with high uptake

  16. Clinical value of SPECT/CT imaging in the diagnosis of bone metastasis

    International Nuclear Information System (INIS)

    Wang Xinhua; Zhao Yanping; Lu Haijian; Dong Zhanfei

    2010-01-01

    Objective: To evaluate the clinical value of 99 Tc m -methylene diphosphonic acid (MDP) SPECT/CT imaging for the diagnosis of bone metastasis. Methods: Patients suspected for bone metastasis and with bone pain of unknown origin were included in this study (n=237). All cases underwent SPECT and CT imaging at 180 min after 99 Tc m -MDP injection. Diagnosis was confirmed by pathology (n=21), more than 2 kinds of radiologieal imaging (MRI, CT, X-ray) (n=106), and clinical follow up in 2 years (n=110). χ 2 -test was used to compare the results of planar and SPECT/CT imaging using SAS 6.12 software. Results: In 237 patients, planar imaging of 142 cases matched the final diagnosis in which 72 had benign lesions and 70 had bone metastases. The definite coincidence rate was 95.30% (142/149). SPECT/CT imaging of 224 cases matched the final diagnosis in which 104 had benign lesions and 120 cases diagnosed as bone metastases. The coincidence and definite coincidence rates were 94.51% (224/237), and 99.48% (192/193). Difference in the definite coincidence rate between planar and SPECT/CT imaging was statistically significant (χ 2 = 5.37, P=0.024). Conclusion: SPECT/CT imaging is valuable for accurate localization of osseous pathology and for improvement of diagnosing bone metastasis. (authors)

  17. Intracoronary thallium-201 scintigraphy after thrombolytic therapy for acute myocardial infarction compared with 10 and 100 day intravenous thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Heller, G.V.; Parker, J.A.; Silverman, K.J.; Royal, H.D.; Kolodny, G.M.; Paulin, S.; Braunwald, E.; Markis, J.E.

    1987-01-01

    Thallium-201 imaging has been utilized to estimate myocardial salvage after thrombolytic therapy for acute myocardial infarction. However, results from recent animal studies have suggested that as a result of reactive hyperemia and delayed necrosis, thallium-201 imaging may overestimate myocardial salvage. To determine whether early overestimation of salvage occurs in humans, intracoronary thallium-201 scans 1 hour after thrombolytic therapy were compared with intravenous thallium-201 scans obtained approximately 10 and 100 days after myocardial infarction in 29 patients. In 10 patients with angiographic evidence of coronary reperfusion, immediate improvement in thallium defects and no interim clinical events, there was no change in imaging in the follow-up studies. Of nine patients with coronary reperfusion but no initial improvement of perfusion defects, none showed worsening of defects in the follow-up images. Six of these patients demonstrated subsequent improvement at either 10 or 100 days after infarction. Seven of 10 patients with neither early evidence of reperfusion nor improvement in perfusion defects had improvement of infarct-related perfusion defects, and none showed worsening. In conclusion, serial scanning at 10 and 100 days after infarction in patients with no subsequent clinical events showed no worsening of the perfusion image compared with images obtained in acute studies. Therefore, there is no evidence that thallium-201 imaging performed early in patients with acute myocardial infarction overestimates improvement

  18. Comparison of SPECT and whole-body planar imaging in radioimmunoscintigraphy with Tc-labeled antibodies

    International Nuclear Information System (INIS)

    Lacic, K.; Bokulic, T.; Lukac, J.; Dakovic, N.; Kusic, Z.

    1994-01-01

    The authors of some recent clinical studies suggested 20-24 hours SPECT imaging as a mandatory procedure in radioimmunoscintigraphy with Tc-labeled antibodies. The aim of our study was to compare whole-body (WB) planar imaging versus SPECT as well as 4-6 hours SPECT to 20-24 hours one. For this purpose we analyzed 33 lesions in 12 postsurgical patients with colorectal carcinoma. Each patient received intravenously 0.5-1.0 mg anti-CEA BW 431/26 murine monoclonal IgG-antibodies labeled with Tc-99m (814-1110 MBq). WB and SPECT imaging were performed at 4-6 and 20-24 hours post infusion. 20-24 hours WB scan imaged more 'hot' and less 'cold' lesions than 4-6 hours one. SPECT scan showed significantly more lesions than WB scan. 20-24 hours SPECT scan detected more 'hot' lesions than 4-6 hours SPECT. At the same time the number of 'cold' lesions decreased in 20-24 hours SPECT in comparison to 4-6 hours one. As a conclusion we can say that our results suggest a superiority of SPECT imaging in comparison to WB scan. Except that, in our opinion performing of a 20-24 hours SPECT scan in radioimmunoscintigraphy with Tc-labeled antibodies should be mandatory. (author)

  19. Comparison of SPECT and whole-body planar imaging in radioimmunoscintigraphy with Tc-labeled antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Lacic, K; Bokulic, T; Lukac, J; Dakovic, N; Kusic, Z [Clinical Hospital Sestre Milosrdnice, Zagreb (Croatia). Dept. of Oncology and Nuclear Medicine

    1994-10-01

    The authors of some recent clinical studies suggested 20-24 hours SPECT imaging as a mandatory procedure in radioimmunoscintigraphy with Tc-labeled antibodies. The aim of our study was to compare whole-body (WB) planar imaging versus SPECT as well as 4-6 hours SPECT to 20-24 hours one. For this purpose we analyzed 33 lesions in 12 postsurgical patients with colorectal carcinoma. Each patient received intravenously 0.5-1.0 mg anti-CEA BW 431/26 murine monoclonal IgG-antibodies labeled with Tc-99m (814-1110 MBq). WB and SPECT imaging were performed at 4-6 and 20-24 hours post infusion. 20-24 hours WB scan imaged more `hot` and less `cold` lesions than 4-6 hours one. SPECT scan showed significantly more lesions than WB scan. 20-24 hours SPECT scan detected more `hot` lesions than 4-6 hours SPECT. At the same time the number of `cold` lesions decreased in 20-24 hours SPECT in comparison to 4-6 hours one. As a conclusion we can say that our results suggest a superiority of SPECT imaging in comparison to WB scan. Except that, in our opinion performing of a 20-24 hours SPECT scan in radioimmunoscintigraphy with Tc-labeled antibodies should be mandatory. (author).

  20. Implications of CT noise and artifacts for quantitative 99mTc SPECT/CT imaging

    International Nuclear Information System (INIS)

    Hulme, K. W.; Kappadath, S. C.

    2014-01-01

    Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI vol = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in 99m Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI vol = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ 140 keV on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed 99m Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect

  1. Pulmonary function-morphologic relationships assessed by SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi

    2012-01-01

    Pulmonary single photon emission computed tomography-computed tomography (SPECT-CT) fusion images provide objective and comprehensive assessment of pulmonary function and morphology relationships at cross-sectional lungs. This article reviewed the noteworthy findings of lung pathophysiology in wide-spectral lung disorders, which have been revealed on SPECT-CT fusion images in 8 years of experience. The fusion images confirmed the fundamental pathophysiologic appearance of lung low CT attenuation caused by airway obstruction-induced hypoxic vasoconstriction and that caused by direct pulmonary arterial obstruction as in acute pulmonary thromboembolism (PTE). The fusion images showed better correlation of lung perfusion distribution with lung CT attenuation changes at lung mosaic CT attenuation (MCA) compared with regional ventilation in the wide-spectral lung disorders, indicating that lung heterogeneous perfusion distribution may be a dominant mechanism of MCA on CT. SPECT-CT angiography fusion images revealed occasional dissociation between lung perfusion defects and intravascular clots in acute PTE, indicating the importance of assessment of actual effect of intravascular colts on peripheral lung perfusion. Perfusion SPECT-CT fusion images revealed the characteristic and preferential location of pulmonary infarction in acute PTE. The fusion images showed occasional unexpected perfusion defects in normal lung areas on CT in chronic obstructive pulmonary diseases and interstitial lung diseases, indicating the ability of perfusion SPECT superior to CT for detection of mild lesions in these disorders. The fusion images showed frequent ''steal phenomenon''-induced perfusion defects extending to the surrounding normal lung of arteriovenous fistulas and those at normal lungs on CT in hepatopulmonary syndrome. Comprehensive assessment of lung function-CT morphology on fusion images will lead to more profound understanding of lung pathophysiology in wide-spectral lung

  2. Arm exercise-thallium imaging testing for the detection of coronary artery disease

    International Nuclear Information System (INIS)

    Balady, G.J.; Weiner, D.A.; Rothendler, J.A.; Ryan, T.J.

    1987-01-01

    Patients with lower limb impairment are often unable to undergo a standard bicycle or treadmill test for the evaluation of coronary artery disease. To establish an alternative method of testing, 50 subjects (aged 56 +/- 10 years) performed arm ergometry testing in conjunction with myocardial thallium scintigraphy. All underwent coronary angiography; significant coronary artery disease (greater than or equal to 70% stenosis) in at least one vessel was present in 41 (82%) of the 50 patients. Thallium scintigraphy was found to have an 83% sensitivity and 78% specificity for detecting coronary disease, compared with a sensitivity and specificity of 54% (p less than 0.01) and 67% (p = NS), respectively, for exercise electrocardiography. In the subgroup of 23 patients who had no prior myocardial infarction or left bundle branch block and were not taking digitalis, thallium scintigraphy had a sensitivity of 80% versus 50% for exercise electrocardiography. Scintigraphy yielded a sensitivity of 84, 74 and 90% for one, two and three vessel disease, respectively. Noninvasive arm ergometry exercise-thallium imaging testing appears to be reliable and useful and should be considered in the evaluation of coronary artery disease in patients with lower limb impairment

  3. The characteristics of SPECT images in childhood benign partial epilepsy

    International Nuclear Information System (INIS)

    Jia Shaowei; Liao Jianxiang; Liu Xiaoyan; Zheng Xiyuan; Qin Jiong; Pan Zhongyun; Zuo Qihua

    1998-01-01

    Purpose: To investigate childhood benign partial epilepsy (BPE) with SPECT. Methods: Double SPECT imaging was performed on 21 cases of BPE at the stage of wake (interval spike discharge) and sleep (spike discharge), under EEG monitoring. The transverse images were reconstructed after digital image subtraction. The quantitative analysis was conducted with brain flow change rate (BFCR) % mathematical model. Results: EEG monitoring demonstrated approximately normal background of 21 cases of BPE during the stage of wake, and spike discharge frequency markedly increased during the stage of sleep, 117 foci were showed by SPeCT in cases of BPE, and the average was 5.6 +- 1.6 foci/case. The characteristics of SPECT transverse images were 1) multiple foci of mirror, 2) mostly seen in Rolandic region, 3) circular symbol, 4) the radioactivity in foci decreased during the stage of wake (interval spike discharge) and increased during the stage of sleep (spike discharge). The concordance of SPECT and EEG was 93.1% (109/117 foci). The BFCR% of all epileptogenic foci exceeded normal limit (99% confidence interval). There was no correlation between the spike discharge frequency and BFCR% (r = 0.45, P>0.05). Conclusions: Regional cerebral blood flow and function were abnormal during the epileptogenic foci were discharging abnormally in BPE

  4. Pinhole SPECT: high resolution imaging of brain tumours in small laboratory animals

    International Nuclear Information System (INIS)

    Franceschim, M.; Bokulic, T.; Kusic, Z.; Strand, S.E.; Erlandsson, K.

    1994-01-01

    The performance properties of pinhole SPECT and the application of this technology to evaluate radionuclide uptake in brain in small laboratory animals were investigated. System sensitivity and spatial resolution measurements of a rotating scintillation camera system were made for a low energy pinhole collimator equipped with 2.0 mm aperture pinhole insert. Projection data were acquired at 4 degree increments over 360 degrees in the step and shoot mode using a 4.5 cm radius of rotation. Pinhole planar and SPECT imaging were obtained to evaluate regional uptake of Tl-201, Tc-99m-MIBI, Tc-99m-HMPAO and Tc-99m-DTPA in tumor and control regions of the brain in a primary brain tumor model in Fisher 344 rats. Pinhole SPECT images were reconstructed using a modified cone- beam algorithm developed from a two dimensional fan-beam filtered backprojection algorithm. The reconstructed transaxial resolution of 2.8 FWHM and system sensitivity of 0.086 c/s/kBq with the 2.0 mm pinhole collimator aperture were measured. Tumor to non-tumor uptake ratios at 19-28 days post tumor cell inoculation varied by a factor > 20:1 on SPECT images. Pinhole SPECT provides an important new approach for performing high resolution imaging: the resolution properties of pinhole SPECT are superior to those which have been achieved with conventional SPECT or PET imaging technologies. (author)

  5. Serial thallium-201 myocardial imaging after dipyridamole infusion: diagnostic utility in detecting coronary stenoses and relationship to regional wall motion

    International Nuclear Information System (INIS)

    Leppo, J.; Boucher, C.A.; Okada, R.D.; Newell, J.B.; Strauss, H.W.; Pohost, G.M.

    1982-01-01

    After a 4-minute i.v. dipyridamole infusion, 0.14 mg/kg/min, serial thallium-201 scans were obtained in 60 patients undergoing cardia catheterization. Forty patients had significant (greater than or equal to50% stenosis) coronary artery disease (CAD), and 20 patients had normal coronary arteries or trivial lesions. The images were graded qualitatively for thallium activity by three observers. Sensitivity was 93% (37 of 40) and specificity was 80% (16 of 20). The sensitivity and specificity of the thallium-201 study were not affected by the extent of CAD, the presence of Q waves, or propranolol therapy. Twenty-seven of 37 patients who had initial defects (73%) had complete thallium redistribution of one or more defects. Patient-by-patient anlaysis using a regression model of all patients showed that the fate of a segmental thallium defect predicted abnormal wall motion by angiography better than ECG Q waves. The presence of propranolol therapy or collaterals did not significantly affect the thallium redistribution results. It is concluded that qualitative interpretation by multiple observers of thallium images after dipyridamole infusion is a highly sensitive and specific test for CAD. After dipyridamole, as with exercise stress, the extent of thallium redistribution is related to the degree of myocardial wall motion abnormality

  6. Individual patient dosimetry using quantitative SPECT imaging

    International Nuclear Information System (INIS)

    Gonzalez, J.; Oliva, J.; Baum, R.; Fisher, S.

    2002-01-01

    An approach is described to provide individual patient dosimetry for routine clinical use. Accurate quantitative SPECT imaging was achieved using appropriate methods. The volume of interest (VOI) was defined semi-automatically using a fixed threshold value obtained from phantom studies. The calibration factor to convert the voxel counts from SPECT images into activity values was determine from calibrated point source using the same threshold value as in phantom studies. From selected radionuclide the dose within and outside a sphere of voxel dimension at different distances was computed through dose point-kernels to obtain a discrete absorbed dose kernel representation around the volume source with uniform activity distribution. The spatial activity distribution from SPECT imaging was convolved with this kernel representation using the discrete Fourier transform method to yield three-dimensional absorbed dose rate distribution. The accuracy of dose rates calculation was validated by software phantoms. The absorbed dose was determined by integration of the dose rate distribution for each volume of interest (VOI). Parameters for treatment optimization such as dose rate volume histograms and dose rate statistic are provided. A patient example was used to illustrate our dosimetric calculations

  7. The current status of SPECT or SPECT/CT in South Korea

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Ik Dong; Choi, Eun Kyung; Chung, Yong An [Dept. of Radiology, Incheon Saint Mary' s HospitalThe Catholic University of Korea, Incheon (Korea, Republic of)

    2017-06-15

    The first step to nuclear medicine in Korea started with introduction of the gamma camera in 1969. Although planar images with the gamma camera give important functional information, they have the limitations that result from 2-dimensional images. Single-photon emission computed tomography (SPECT) due to its 3-dimensional image acquisition is superior to earlier planar gamma imaging in image resolution and diagnostic accuracy. As demand for a hybrid functional and anatomical imaging device has increased, integrated SPECT/CT systems have been used. In Korea, SPECT/CT was for the first time installed in 2003. SPECT/CT can eliminate many possible pitfalls on SPECT-alone images, making better attenuation correction and thereby improving image quality. Therefore, SPECT/CT is clinically preferred in many hospitals in various aspects. More recently, additional SPECT/CT images taken from the region with equivocal uptake on planar images have been helpful in making precise interpretation as part of their clinical workup in postoperative thyroid cancer patients. SPECT and SPECT/CT have various advantages, but its clinical application has gradually decreased in recent few years. While some researchers investigated the myocardial blood flow with cardiac PET using F-18 FDG or N-13 ammonia, myocardial perfusion SPECT is, at present, the radionuclide imaging study of choice for the risk stratification and guiding therapy in the coronary artery disease patients in Korea. New diagnostic radiopharmaceuticals for AD have received increasing attention; nevertheless, brain SPECT will remain the most reliable modality evaluating cerebral perfusion.

  8. The group study of diagnostic efficacy of cerebro-vascular disease by I-123 IMP SPECT images obtained with ring type SPECT scanner

    International Nuclear Information System (INIS)

    Machida, Kikuo; Honda, Norinari; Matsumoto, Toru

    1991-01-01

    We performed two image reading experiments in order to investigate the diagnostic capability of I-123 IMP SPECT obtained by the ring type SPECT scanner in cerebro-vascular disease. Fourteen physicians diagnosed SPECT images of 55 cases with reference to clinical neurological information, first without brain XCT images and second with XCT images. Each physician detected perfusion defects and redistributions of I-123 IMP and assigned a confidence level of abnormality for these SPECT findings by means of five rating method. From results obtained by ROC analysis, we concluded as follows. (1) Generally, I-123 IMP SPECT is a stable diagnostic modality in the diagnosis of cerebro-vascular disease and the image reading of XCT had no effects on the diagnosis of SPECT on the whole of physician. (2) However, there were unnegligible differences among individuals in the detectability of findings and the effect of XCT image reading. (3) Detectability of redistribution of I-123 IMP was lower than that of perfusion defect and inter-observer variation in the diagnostic performance for redistribution was larger than that of perfusion defect. The results suggest that it is necessary to standardize diagnostic criteria among physicians for redistribution of I-123 IMP. (author)

  9. Frameless image registration of X-ray CT and SPECT by volume matching

    International Nuclear Information System (INIS)

    Tanaka, Yuko; Kihara, Tomohiko; Yui, Nobuharu; Kinoshita, Fujimi; Kamimura, Yoshitsugu; Yamada, Yoshifumi.

    1998-01-01

    Image registration of functional (SPECT) and morphological (X-ray CT/MRI) images is studied in order to improve the accuracy and the quantity of the image diagnosis. We have developed a new frameless registration method of X-ray CT and SPECT image using transmission CT image acquired for absorption correction of SPECT images. This is the automated registration method and calculates the transformation matrix between the two coordinate systems of image data by the optimization method. This registration method is based on the similar physical property of X-ray CT and transmission CT image. The three-dimensional overlap of the bone region is used for image matching. We verified by a phantom test that it can provide a good result of within two millimeters error. We also evaluated visually the accuracy of the registration method by the application study of SPECT, X-ray CT, and transmission CT head images. This method can be carried out accurately without any frames. We expect this registration method becomes an efficient tool to improve image diagnosis and medical treatment. (author)

  10. The effect of Compton scattering on quantitative SPECT imaging

    International Nuclear Information System (INIS)

    Beck, J.W.; Jaszczak, R.J.; Starmer, C.F.

    1982-01-01

    A Monte Carlo code has been developed to simulate the response of a SPECT system. The accuracy of the code has been verified and has been used in this research to study and illustrate the effects of Compton scatter on quantitative SPECT measurements. The effects of Compton scattered radiation on gamma camera response have been discussed by several authors, and will be extended to rotating gamma camera SPECT systems. The unique feature of this research includes the pictorial illustration of the Compton scattered and the unscattered components of the photopeak data on SPECT imaging by simulating phantom studies with and without Compton scatter

  11. Evaluation of myocardial involvement in Duchenne progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Yamamoto, Shuhei; Okada, Mitsuhiro

    1983-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. The qualitative analysis was performed in anterior, 3 left anterior oblique and left lateral projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in LV posterolateral or posterior walls (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle changes or thoracic deformities assessed by transmission computed tomography. Slightly increased thallium-201 activity in RV free wall and lungs was shown in nine and one patient, respectively. The extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. The myocardial scintigraphic changes were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies in 2 to 3 years. It was concluded that the thallium myocardial perfusion imaging was a useful clinical technique to evaluate the cardiomyopathy in Duchenne progressive muscular dystrophy. (author)

  12. Evaluation of myocardial involvement in Duchenne progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Naoki; Yamamoto, Shuhei; Okada, Mitsuhiro (Nagoya Univ. (Japan). Faculty of Medicine)

    1983-12-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. The qualitative analysis was performed in anterior, 3 left anterior oblique and left lateral projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in LV posterolateral or posterior walls (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle changes or thoracic deformities assessed by transmission computed tomography. Slightly increased thallium-201 activity in RV free wall and lungs was shown in nine and one patient, respectively. The extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. The myocardial scintigraphic changes were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies in 2 to 3 years. It was concluded that the thallium myocardial perfusion imaging was a useful clinical technique to evaluate the cardiomyopathy in Duchenne progressive muscular dystrophy.

  13. Cortical region of interest definition on SPECT brain images using X-ray CT registration

    Energy Technology Data Exchange (ETDEWEB)

    Tzourio, N.; Sutton, D. (Commissariat a l' Energie Atomique, Orsay (France). Service Hospitalier Frederic Joliot); Joliot, M. (Commissariat a l' Energie Atomique, Orsay (France). Service Hospitalier Frederic Joliot INSERM, Orsay (France)); Mazoyer, B.M. (Commissariat a l' Energie Atomique, Orsay (France). Service Hospitalier Frederic Joliot Antenne d' Information Medicale, C.H.U. Bichat, Paris (France)); Charlot, V. (Hopital Louis Mourier, Colombes (France). Service de Psychiatrie); Salamon, G. (CHU La Timone, Marseille (France). Service de Neuroradiologie)

    1992-11-01

    We present a method for brain single photon emission computed tomography (SPECT) analysis based on individual registration of anatomical (CT) and functional ([sup 133]Xe regional cerebral blood flow) images and on the definition of three-dimensional functional regions of interest. Registration of CT and SPECT is performed through adjustment of CT-defined cortex limits to the SPECT image. Regions are defined by sectioning a cortical ribbon on the CT images, copied over the SPECT images and pooled through slices to give 3D cortical regions of interest. The proposed method shows good intra- and interobserver reproducibility (regional intraclass correlation coefficient [approx equal]0.98), and good accuracy in terms of repositioning ([approx equal]3.5 mm) as compared to the SPECT image resolution (14 mm). The method should be particularly useful for analysing SPECT studies when variations in brain anatomy (normal or abnormal) must be accounted for. (orig.).

  14. Performance of Thallium-201 Electrocardiography-gated Myocardial Perfusion Single Photon Emission Computed Tomography to Assess Left Ventricular Function

    Directory of Open Access Journals (Sweden)

    Guang-Uei Hung

    2005-05-01

    Full Text Available This study evaluated the performance of gated single photon emission computed tomography (SPECT with thallium-201 (201Tl in assessing left ventricular ejection fraction (LVEF, end-diastolic volume (EDV, and end-systolic volume (ESV in Taiwanese by determining repeatability and correlation with two-dimensional (2D echocardiography. A total of 18 patients underwent two sequential gated SPECT acquisitions within 30 minutes in the resting state to assess repeatability. Another 28 patients who underwent gated SPECT and 2D echocardiography within 7 days were included for comparison. The two sequential measurements were well correlated with respect to LVEF, EDV, and ESV (r = 0.97, 0.95, and 0.97, respectively, all p < 0.0001. Bland-Altman analysis revealed that two standard deviations of the absolute difference between the two sequential measurements for LVEF, EDV, and ESV were 6.4%, 16.8 mL, and 8.6 mL, respectively. For LVEF, EDV, and ESV, correlations between redistribution 201Tl-gated SPECT and echocardiography were also excellent (all r = 0.83, p < 0.0001. LVEF was similar with 201Tl-gated SPECT and echocardiography, but EDV and ESV were significantly higher with echocardiography (p < 0.05. Our study revealed that 201Tl-gated SPECT has high repeatability and excellent correlation with echocardiography for the assessment of LVEF and volumes in Taiwanese. These results support the clinical application of gated SPECT in routine 201Tl myocardial perfusion imaging in Taiwanese.

  15. Exercise thallium-201 imaging in complete left bundle branch block and the prevalence of septal perfusion defects

    International Nuclear Information System (INIS)

    Jazmati, B.; Sadaniantz, A.; Emaus, S.P.; Heller, G.V.

    1991-01-01

    To determine the prevalence of septal defects in a generalized referral population, the records of 93 consecutive patients with complete left bundle branch block (BBB) who underwent symptom-limited treadmill exercise testing with thallium-201 myocardial imaging over a 3-year period were reviewed. Segmental analysis of the planar thallium-201 images was performed in a blinded fashion with agreement by consensus. Computerized quantitative analysis of the images also was independently performed, and was correlated with the visual interpretations. Forty-seven patients (51%) had normal images, and 46 (49%) had defects of greater than or equal to 2 segments. In the abnormal studies, only 13 patients (14% of the total population) had septal defects, while a much higher number of patients, 33 (39%), had inferior or apical defects, or both. Coronary angiography was performed in 6 patients with septal defects: Significant narrowing of the left anterior descending coronary artery was found in 4 patients, a narrowed right coronary artery was found in 1, and normal coronary arteries were seen in the other patient. In conclusion, whereas previous studies have suggested a high percentage of false-positive septal defects in patients with left BBB, this study demonstrates a low prevalence (14%) of septal defects in a large population of unselected patients presenting for exercise thallium-201 imaging. Therefore, exercise thallium-201 imaging remains a useful procedure for evaluating patients with complete left BBB

  16. Hybrid SPECT/CT imaging in neurology.

    Science.gov (United States)

    Ciarmiello, Andrea; Giovannini, Elisabetta; Meniconi, Martina; Cuccurullo, Vincenzo; Gaeta, Maria Chiara

    2014-01-01

    In recent years, the SPECT/CT hybrid modality has led to a rapid development of imaging techniques in nuclear medicine, opening new perspectives for imaging staff and patients as well. However, while, the clinical role of positron emission tomography-computed tomography (PET-CT) is well consolidated, the diffusion and the consequent value of single-photon emission tomography-computed tomography (SPECT-CT) has yet to be weighed, Hence, there is a need for a careful analysis, comparing the "potential" benefits of the hybrid modality with the "established" ones of the standalone machine. The aim of this article is to analyze the impact of this hybrid tool on the diagnosis of diseases of the central nervous system, comparing strengths and weaknesses of both modalities through the use of SWOT analysis.

  17. Benign versus malignant osseous lesions in spine: differentiation by means of bone SPECT/CT fused image

    International Nuclear Information System (INIS)

    Yao Zhiming; Qu Wanying

    2004-01-01

    This study compared the efficiency of SPECT-CT fused image with planar bone scan, bone SPECT and CT in differentiating malignant from benign lesions and detecting metastases to the spine. Methods. Total 144 patients with spinal lesions underwent planar bone scan (WB), single photon tomography (SPECT), CT and SPECT-CT fused image by a SPECT/CT system. The malignant or benign nature of lesions was proved by radiological Methods, histological findings, 6-24 month follow-up, or all of these. The diagnostic results was divided into 4 types, i.e., normal, benign, doubtful malignant and malignant. Results. There were 137 malignant and 252 benign lesions in 144 patients, respectively. The percentages of doubtful malignant diagnosed by WB, SPECT, CT and fused image are 22.6%, 5.1%, 9.5% and 0%, respectively, p < 0.01-0.001, except for the comparison between the percentages of SPECT and CT. Sensitivities in detection of malignant lesions by WB, SPECT, CT and fused image are 75.2%, 94.2%, 96.6% and 99.3%, respectively, P < 0.001, excepting for the comparisons between those of SPECT and CT, and between those of CT and fused image. The sensitivities m detection of benign lesions by WB, SPECT, CT and fused image are, 56.7%, 86.5%, 90.1% and 96.8%, respectively, P < 0.005 - 0.001, excepting for the comparison between those of SPECT and CT. The specificities in detection of maliganant lesions by WB, SPECT, CT and fused image are 70.6%, 88.9%, 97.2% and 97.6%, respectively, P < 0.001, excepting for the comparison between those of CT and fused image. Conclusion. Bone SPECT-CT fused image has highest diagnostic and differentiating diagnostic values in detection of spinal abnormalities over the planar bone scanning and SPECT. The CT by present SPECT/CT system can complement planar bone scanning and SPECT and is clinically valuable in detection of spinal abnormalities. (authors)

  18. A methodology for generating normal and pathological brain perfusion SPECT images for evaluation of MRI/SPECT fusion methods: application in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Grova, C [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Jannin, P [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Biraben, A [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Buvat, I [INSERM U494, CHU Pitie Salpetriere, Paris (France); Benali, H [INSERM U494, CHU Pitie Salpetriere, Paris (France); Bernard, A M [Service de Medecine Nucleaire, Centre Eugene Marquis, Rennes (France); Scarabin, J M [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Gibaud, B [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France)

    2003-12-21

    Quantitative evaluation of brain MRI/SPECT fusion methods for normal and in particular pathological datasets is difficult, due to the frequent lack of relevant ground truth. We propose a methodology to generate MRI and SPECT datasets dedicated to the evaluation of MRI/SPECT fusion methods and illustrate the method when dealing with ictal SPECT. The method consists in generating normal or pathological SPECT data perfectly aligned with a high-resolution 3D T1-weighted MRI using realistic Monte Carlo simulations that closely reproduce the response of a SPECT imaging system. Anatomical input data for the SPECT simulations are obtained from this 3D T1-weighted MRI, while functional input data result from an inter-individual analysis of anatomically standardized SPECT data. The method makes it possible to control the 'brain perfusion' function by proposing a theoretical model of brain perfusion from measurements performed on real SPECT images. Our method provides an absolute gold standard for assessing MRI/SPECT registration method accuracy since, by construction, the SPECT data are perfectly registered with the MRI data. The proposed methodology has been applied to create a theoretical model of normal brain perfusion and ictal brain perfusion characteristic of mesial temporal lobe epilepsy. To approach realistic and unbiased perfusion models, real SPECT data were corrected for uniform attenuation, scatter and partial volume effect. An anatomic standardization was used to account for anatomic variability between subjects. Realistic simulations of normal and ictal SPECT deduced from these perfusion models are presented. The comparison of real and simulated SPECT images showed relative differences in regional activity concentration of less than 20% in most anatomical structures, for both normal and ictal data, suggesting realistic models of perfusion distributions for evaluation purposes. Inter-hemispheric asymmetry coefficients measured on simulated data were

  19. The impact of exercise myocardial perfusion SPECT imaging on the selection of patients for coronary angiography

    International Nuclear Information System (INIS)

    Song Liping; He Zuoxiang; Liu Xiujie; Shi Rongfang; Liu Yunzhong; Tian Yueqin; Zhang Xiaoli; Qin Xuewen; Chen Jilin; Gao Runlin

    2001-01-01

    Objective: Exercise 99 Tc m -MIBI myocardial perfusion SPECT is accurate for the diagnosis of coronary artery disease (CAD). This study assessed the impact of exercise myocardial perfusion imaging on the selection of patients for coronary angiography. Methods: 2188 consecutive patients who underwent exercise myocardial perfusion SPECT in authors' department in 1999 were retrospectively analyzed. Among them, 1807 were men, 381 women (average age: 53.5 +- 7.2 years). Overall, exercise myocardial SPECT was normal in 1731 patients, abnormal in 359 cases, and equivocal in 98 patients. There were 141 patients who underwent CAG within 60 days after myocardial SPECT. Results: Overall, 12% of the patients with abnormal SPECT imaging underwent coronary angiography, but only 5% of the patients with a normal SPECT imaging did (P < 0.001). Among these 141 patients who underwent coronary angiography, significant coronary stenosis was present in 91% of the patients who had had an abnormal SPECT imaging, but only 8% of those who had had a normal SPECT imaging (P < 0.001). In those patients who underwent coronary angiography, revascularization rate was 25% for the patients with abnormal SPECT imaging, but only 1% for the patients with a normal SPECT imaging. Conclusion: The results of exercise myocardial perfusion SPECT have a significant impact on the selection of patients for coronary angiography and revascularization

  20. Thallium 201 scintigraphy of the myocardium. A bibliographical survey for image optimisation

    International Nuclear Information System (INIS)

    Chatelier, Luc.

    1979-01-01

    At the request of a Nuclear Medicine Service we compiled a review of the literature on thallium 201 myocardium scintigraphy in order to define the optimum parameters for image acquisition; included also are the bibliograhical references of studies on the sensitivities, specificities and accuracies of this technique as compared with electrocardiography in the diagnosis and evaluation of ischemic heart diseases. This examination seems to have a part to play at all stages in the evaluation of ischemic heart diseases, whether for the detection (ischemia) emergency handling (thrombosis) or post-surgical checking (permeability of an aorto-coronary transplant) of these diseases, the great frequency and gravity of which have no longer to be proved. This study covers the whole period since thallium scintigraphy began (1970) until June 1978. Thallium seems to have a great future in cardiology and may be even in other fields since its use is quoted (in only a few publications as yet) for brain, kidney and pancreas scintigraphy [fr

  1. Adaptive Angular Sampling for SPECT Imaging

    OpenAIRE

    Li, Nan; Meng, Ling-Jian

    2011-01-01

    This paper presents an analytical approach for performing adaptive angular sampling in single photon emission computed tomography (SPECT) imaging. It allows for a rapid determination of the optimum sampling strategy that minimizes image variance in regions-of-interest (ROIs). The proposed method consists of three key components: (a) a set of close-form equations for evaluating image variance and resolution attainable with a given sampling strategy, (b) a gradient-based algor...

  2. Simultaneous maximal exercise radionuclide angiography and thallium stress perfusion imaging

    International Nuclear Information System (INIS)

    Narahara, K.A.; Mena, I.; Maublant, J.C.; Brizendine, M.; Criley, J.M.

    1984-01-01

    Gold-195m is a new ultra-short-lived radionuclide that can be used for cardiac studies. Accurate, reproducible ejection fraction and ventricular wall motion studies can be obtained from first-transit angiography using commercially available imaging and image-processing equipment. The short half-life of gold-195m (30.5 seconds) makes simultaneous dual isotope imaging possible and substantially reduces the radiation exposure from the isotope angiography. The feasibility and possible benefits of performing dual radionuclide studies were evaluated during a single exercise stress test in 24 subjects with known coronary artery disease (CAD) and in 20 normal volunteers. High-quality first-transit angiograms were obtained in all subjects. An 83% sensitivity and 95% specificity for detecting CAD with thallium-201 imaging was noted in this investigation, suggesting that its diagnostic accuracy was not altered by simultaneous dual isotone imaging. When segmental left ventricular (LV) wall motion was compared with thallium-201 perfusion imaging, divergent results were noted in 15 of 44 subjects. An analysis of the ejection fraction (EF) results at rest and stress provided additional information that could be useful in assessing the clinical significance of such differences in segmental wall motion and perfusion. Simultaneous dual isotope imaging appears to be appropriate for situations in which both LV perfusion and function require evaluation. The use of gold-195m allows such information to be obtained from a single exercise test and can thereby reduce the cost and time required for noninvasive evaluations of patients for CAD

  3. Influence of void on image quality of industrial SPECT

    International Nuclear Information System (INIS)

    Park, J G; Jung, S H; Kim, J B; Moon, J; Kim, C H

    2013-01-01

    Industrial single photon emission computed tomography (SPECT) is a promising technique to determine the dynamic behavior of industrial process media and has been developed in the Korea Atomic Energy Research Institute. The present study evaluated the influence of a void, which is presence in multiphase reactors of industrial process, on the image quality of an industrial SPECT. The results are very encouraging; that is, the performance of the industrial SPECT system is little influenced by the presence of a void, which means that industrial SPECT is an appropriate tool to estimate the dynamic characteristics of the process media in a water-air phase bubble column with a static gas sparger

  4. 3D composite image, 3D MRI, 3D SPECT, hydrocephalus

    International Nuclear Information System (INIS)

    Mito, T.; Shibata, I.; Sugo, N.; Takano, M.; Takahashi, H.

    2002-01-01

    The three-dimensional (3D)SPECT imaging technique we have studied and published for the past several years is an analytical tool that permits visual expression of the cerebral circulation profile in various cerebral diseases. The greatest drawback of SPECT is that the limitation on precision of spacial resolution makes intracranial localization impossible. In 3D SPECT imaging, intracranial volume and morphology may vary with the threshold established. To solve this problem, we have produced complimentarily combined SPECT and helical-CT 3D images by means of general-purpose visualization software for intracranial localization. In hydrocephalus, however, the key subject to be studied is the profile of cerebral circulation around the ventricles of the brain. This suggests that, for displaying the cerebral ventricles in three dimensions, CT is a difficult technique whereas MRI is more useful. For this reason, we attempted to establish the profile of cerebral circulation around the cerebral ventricles by the production of combined 3D images of SPECT and MRI. In patients who had shunt surgery for hydrocephalus, a difference between pre- and postoperative cerebral circulation profiles was assessed by a voxel distribution curve, 3D SPECT images, and combined 3D SPECT and MRI images. As the shunt system in this study, an Orbis-Sigma valve of the automatic cerebrospinal fluid volume adjustment type was used in place of the variable pressure type Medos valve currently in use, because this device requires frequent changes in pressure and a change in pressure may be detected after MRI procedure. The SPECT apparatus used was PRISM3000 of the three-detector type, and 123I-IMP was used as the radionuclide in a dose of 222 MBq. MRI data were collected with an MAGNEXa+2 with a magnetic flux density of 0.5 tesla under the following conditions: field echo; TR 50 msec; TE, 10 msec; flip, 30ueK; 1 NEX; FOV, 23 cm; 1-mm slices; and gapless. 3D images are produced on the workstation TITAN

  5. Thallium-201 myocardial imaging during coronary vasodilation induced by oral dipyridamole

    International Nuclear Information System (INIS)

    Gould, K.L.; Sorenson, S.G.; Albro, P.; Caldwell, J.H.; Chaudhuri, T.; Hamilton, G.W.

    1986-01-01

    Myocardial perfusion imaging of 201 TI injected during maximum exercise has been an important diagnostic tool for coronary artery disease. Pharmacologic coronary vasodilation by i.v. infusion of dipyridamole may be used in lieu of exercise stress for purposes of diagnostic perfusion imaging. However, i.v. dipyridamole is not currently available from commercial sources for widespread routine use. Accordingly, this study was carried out in order to determine whether high dose, oral dipyridamole would be useful as a coronary vasodilator for purposes of diagnostic perfusion imaging. Fifty-eight patients undergoing diagnostic coronary arteriography also had myocardial perfusion imaging with 201TI under conditions of rest, maximum exercise stress, and high dose oral dipyridamole. Of those patients who had a defect on exercise thallium images, 75% also had a perfusion defect on thallium images after high dose oral dipyridamole. These results indicate that oral dipyridamole causes sufficient coronary arteriolar vasodilation and increase of coronary flow in nonstenotic arteries to identify perfusion defects comparable to those seen on maximum exercise stress in at least 75% of cases. In 25% of patients with exercise defects, no perfusion defect was seen after oral dipyridamole. Thus, oral dipyridamole is a potent coronary vasodilator, comparable to exercise stress in most cases, but in a minority of patients may not be comparable to exercise stress

  6. Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Eun Jung; Cho, Ihn Ho [Yeungnam University Hospital, Daegu (Korea, Republic of); Kang, Won Jun [Yonsei University Hospital, Seoul (Korea, Republic of); Kim, Seong Min [Chungnam National University Medical School and Hospital, Daejeon (Korea, Republic of); Won, Kyoung Sook [Keomyung University Dongsan Hospital, Daegu (Korea, Republic of); Lim, Seok Tae [Chonbuk National University Medical School and Hospital, Jeonju (Korea, Republic of); Hwang, Kyung Hoon [Gachon University Gil Hospital, Incheon (Korea, Republic of); Lee, Byeong Il; Bom, Hee Seung [Chonnam National University Medical School and Hospital, Gwangju (Korea, Republic of)

    2009-12-15

    Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Forty-eight patients (M:F=26:22, Age: 63.3{+-}10.4 years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

  7. Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study.

    Directory of Open Access Journals (Sweden)

    Oliver S Grosser

    Full Text Available Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT or positron emission tomography (PET with computed tomography (CT. Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR on the image quality of the low-dose CT images.Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88 and the contrast-to-noise ratio (CNR was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04. In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001.In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality.

  8. State-of-the-art of small animal imaging with high-resolution SPECT

    International Nuclear Information System (INIS)

    Nikolaus, S.; Wirrwar, A.; Antke, C.; Kley, K.; Mueller, H.W.

    2005-01-01

    During the recent years, in vivo imaging of small animals using SPECT has become of growing relevance. Along with the development of dedicated high-resolution small animal SPECT cameras, an increasing number of conventional clinical scanners has been equipped with single or multipinhole collimators. This paper reviews the small animal tomographs, which are operating at present and compares their performance characteristics. Furthermore, we describe the in vivo imaging studies, which have been performed so far with the individual scanners and survey current approaches to optimize molecular imaging with small animal SPECT. (orig.)

  9. DMSA SPECT imaging using oblique reconstruction in a paediatric population - benefits and technical considerations

    International Nuclear Information System (INIS)

    Parsons, G.; Ford, M.; Crisp, J.; Bernard, E.; Howman-Giles, R.

    1997-01-01

    Full text: DMSA renal scans are frequently requested for the diagnosis and follow-up of acute pyelonephritis and cortical scarring. This study was designed to:- 1. evaluate oblique reconstruction of DMSA SPECT over standard plane reconstruction and planar imaging; and 2. report on the technical aspects important in obtaining high quality DMSA SPECT, particularly in neonates. Over seven months, 210/231 (91 %) of DMSA scans were performed with SPECT on children from age nine days to 16 years, the median age being 2.5 years. 65 patients (31 %) were under one year and 39 (18%) were under six months. Planar and SPECT imaging with standard plane reconstruction and oblique reorientation was performed on the Siemens triple-headed gamma camera. High quality SPECT images were obtained on the smallest babies using a paediatric palette, and were of comparable quality to those of older children. At the time of reporting, the nuclear medicine physician assessed the diagnostic value of the three types of date presented: (1) planar images; (2) standard plane SPECT reconstruction; and (3) oblique SPECT reconstruction. Cortical defects were identified separately for upper, middle and lower poles. Three physicians concluded that high quality SPECT is superior to planar images when assessing the renal cortex. In addition, oblique reorientation is superior to standard reconstruction, particularly at the upper and lower poles. SPECT is now performed routinely on patients of all ages, and the oblique sagittal and coronal reorientation is now used in place of the standard reconstruction

  10. Evaluation of image reconstruction methods for 123I-MIBG-SPECT. A rank-order study

    International Nuclear Information System (INIS)

    Soederberg, Marcus; Mattsson, Soeren; Oddstig, Jenny; Uusijaervi-Lizana, Helena; Leide-Svegborn, Sigrid; Valind, Sven; Thorsson, Ola; Garpered, Sabine; Prautzsch, Tilmann; Tischenko, Oleg

    2012-01-01

    Background: There is an opportunity to improve the image quality and lesion detectability in single photon emission computed tomography (SPECT) by choosing an appropriate reconstruction method and optimal parameters for the reconstruction. Purpose: To optimize the use of the Flash 3D reconstruction algorithm in terms of equivalent iteration (EI) number (number of subsets times the number of iterations) and to compare with two recently developed reconstruction algorithms ReSPECT and orthogonal polynomial expansion on disc (OPED) for application on 123 I-metaiodobenzylguanidine (MIBG)-SPECT. Material and Methods: Eleven adult patients underwent SPECT 4 h and 14 patients 24 h after injection of approximately 200 MBq 123 I-MIBG using a Siemens Symbia T6 SPECT/CT. Images were reconstructed from raw data using the Flash 3D algorithm at eight different EI numbers. The images were ranked by three experienced nuclear medicine physicians according to their overall impression of the image quality. The obtained optimal images were then compared in one further visual comparison with images reconstructed using the ReSPECT and OPED algorithms. Results: The optimal EI number for Flash 3D was determined to be 32 for acquisition 4 h and 24 h after injection. The average rank order (best first) for the different reconstructions for acquisition after 4 h was: Flash 3D 32 > ReSPECT > Flash 3D 64 > OPED, and after 24 h: Flash 3D 16 > ReSPECT > Flash 3D 32 > OPED. A fair level of inter-observer agreement concerning optimal EI number and reconstruction algorithm was obtained, which may be explained by the different individual preferences of what is appropriate image quality. Conclusion: Using Siemens Symbia T6 SPECT/CT and specified acquisition parameters, Flash 3D 32 (4 h) and Flash 3D 16 (24 h), followed by ReSPECT, were assessed to be the preferable reconstruction algorithms in visual assessment of 123 I-MIBG images

  11. The clinical application of SPECT myocardial perfusion imaging with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Dong Weiyu

    1992-01-01

    This paper reported 182 SPECT myocardial perfusion images with China made 99m Tc-MIBI and were compared with ECG and UCG. The sensitivity of SPECT in ischemic were 91.2% and was higher than ECG (74.9%)and UCG (61.8%) (P < 0.01). And its specificity, accuracy and positive predictive rate were 78.3%, 90% and 97% respectively. Besides 9 cases have reverse distribution after exercise and rest images. In some ICD patients had shown their SPECT images, the perfusion defects in exercise as well as in rest image

  12. SPECT/CT imaging in children with papillary thyroid carcinoma

    International Nuclear Information System (INIS)

    Kim, Hwa-Young; Gelfand, Michael J.; Sharp, Susan E.

    2011-01-01

    SPECT/CT improves localization of single photon-emitting radiopharmaceuticals. To determine the utility of SPECT/CT in children with papillary thyroid carcinoma. 20 SPECT/CT and planar studies were reviewed in 13 children with papillary thyroid carcinoma after total thyroidectomy. Seven studies used I-123 and 13 used I-131, after elevating TSH by T4 deprivation or intramuscular thyrotropin alfa. Eight children had one study and five children had two to four studies. Studies were performed at initial post-total thyroidectomy evaluation, follow-up and after I-131 treatment doses. SPECT/CT was performed with a diagnostic-quality CT unit in 13 studies and a localization-only CT unit in 7. Stimulated thyroglobulin was measured (except in 2 cases with anti-thyroglobulin antibodies). In 13 studies, neck activity was present but poorly localized on planar imaging; all foci of uptake were precisely localized by SPECT/CT. Two additional foci of neck uptake were found on SPECT/CT. SPECT/CT differentiated high neck uptake from facial activity. In six studies (four children), neck uptake was identified as benign by SPECT/CT (three thyroglossal duct remnants, one skin contamination, two by precise anatomical CT localization). In two children, SPECT/CT supported a decision not to treat with I-131. When SPECT/CT was unable to identify focal uptake as benign, stimulated thyroglobulin measurements were valuable. In three of 13 studies with neck uptake, SPECT/CT provided no useful additional information. SPECT/CT precisely localizes neck iodine uptake. In small numbers of patients, treatment is affected. SPECT/CT should be used when available in thyroid carcinoma patients. (orig.)

  13. Improvements in SPECT technology for cerebral imaging

    International Nuclear Information System (INIS)

    Esser, P.D.

    1985-01-01

    Advancement in three major areas of SPECT (single photon emission computed tomography) technology have resulted in improved image quality for cerebral studies. In the first area, single-crystal camera electronics, extensive use of microprocessors, custom digital circuitry, an data bus architecture have allowed precise external control of all gantry motions and improved signal processing. The new digital circuitry permits energy, uniformity, and linearity corrections to be an integral part of the processing electronics. Calibration of these correlations is controlled by algorithms stored in the camera's memory. The second area of improved SPECT technology is camera collimation and related imaging techniques. In this area, system resolution has been improved without loss of sensitivity by decreasing the air gap between patient and collimator surface. Since cerebral studies characteristically image high-contrast regions less than 1 cm in size, image quality has been improved by increasing collimator resolution even at the expense of sensitivity. Increased resolution also improved image contrast for studies using 123 I-labeled pharmaceuticals with 3% to 4% 124 I contamination. 65 references

  14. Technetium SPECT agents for imaging heart and brain

    International Nuclear Information System (INIS)

    Linder, K.E.

    1990-01-01

    One major goal of radiopharmaceutical research has been the development of technetium-based perfusion tracers for SPECT imaging of the heart and brain. The recent clinical introduction of the technetium complexes HM-PAO, ECD and DMG-2MP for brain imaging, and of CDO-MEB and MIBI for heart imaging promises to revolutionize the field of nuclear medicine. All of these agents appear to localize in the target tissue in proportion to blood flow, but their mechanisms of localization and/or retention may differ quite widely. In this talk, a survey of the new technetium SPECT agents will be presented. The inorganic and biological chemistry of these complexes, mechanisms of uptake and retention, QSAR studies, and potential clinical applications are discussed

  15. Bull's-eye map of myocardial perfusion MR imaging. Comparison with SPECT

    International Nuclear Information System (INIS)

    Nomura, Yukihiro; Nanjo, Shuji; Yamazaki, Junichi; Yoshikawa, Kohki; Inoue, Yusuke

    2003-01-01

    When diagnosing heart disease, chest roentgenograms, ultrasonography, single-photon emission computed tomography (SPECT), and coronary arteriography are usually performed. Magnetic resonance (MR) imaging is not widely used for evaluating heart disease. Recent technological progress has allowed high quality images of the heart to be reliably obtained. A routine MR study taking about 30-40 minutes can provide a large amount of diagnostic information, such as cardiac structure, function, perfusion, and myocardial viability. The analysis software that can offer Bull's-eye maps from myocardial perfusion images has recently become commercially available. In this study, the characteristics of Bull's-eye mapping of MR imaging is compared with that of Bull's-eye mapping of SPECT using the same heart phantom. The difference in the image quality of the Bull's-eye maps was evaluated among the receiver coils of MR imaging. On Bull's-eye maps from both MR imaging and SPECT, decreased signal intensity was noted in the posterolateral wall. The degree of decrease in the signal of the MR imaging was more prominent than of SPECT. The decrease was severe for the general-purpose receive-only flexible (GPFLEX) coil, moderate for the cardiac and TORSO coil, and slight for the body coil. In the selection of a coil, it is necessary to take into consideration the trade-off between the distribution of signal intensity and the signal-to-noise ratio (SNR). (author)

  16. Metabolic imaging using SPECT

    International Nuclear Information System (INIS)

    Taki, Junichi; Matsunari, Ichiro

    2007-01-01

    In normal condition, the heart obtains more than two-thirds of its energy from the oxidative metabolism of long chain fatty acids, although a wide variety of substrates such as glucose, lactate, ketone bodies and amino acids are also utilised. In ischaemic myocardium, on the other hand, oxidative metabolism of free fatty acid is suppressed and anaerobic glucose metabolism plays a major role in residual oxidative metabolism. Therefore, metabolic imaging can be an important technique for the assessment of various cardiac diseases and conditions. In SPECT, several iodinated fatty acid traces have been introduced and studied. Of these, 123 I-labelled 15-(p-iodophenyl)3-R, S-methylpentadecanoic acid (BMIPP) has been the most commonly used tracer in clinical studies, especially in some of the European countries and Japan. In this review article, several fatty acid tracers for SPECT are characterised, and the mechanism of uptake and clinical utility of BMIPP are discussed in detail. (orig.)

  17. Quantification of the right ventricular wall using stress myocardial emission computed tomography with thallium-201 in normal subjects

    International Nuclear Information System (INIS)

    Akanabe, Hiroshi; Oshima, Motoo; Sakuma, Sadayuki; Yamamoto, Shuhei; Kawai, Naoki; Sotobata, Iwao

    1985-01-01

    Although many studies of quantitative analysis of left ventricular myocardial wall (LVMW) have been reported using stress thallium-201 (Tl-201), few reports of right ventricular myocardial wall (RVMW) have been estimated. In this study we determined whether single photon emission computed tomography (SPECT) with Tl-201 could accurately define normal range of RVMW in normal subjects. Twelve persons who have no valvular disease, nor coronary artery disease were included in this study. Stress SPECT study was reconstructed to make a short axial images of ventricles. RVMW and LVMW were flagged by mamual. Each ventricle was divided into 36 parts at every 10 degree. Relative activity counts in each ventricle were calculated as a percent counts of maximum counts in left ventricle. The normal range of RVMW with stress SPECT was as follows: anterior wall (33.2 +- 11.4 %, mean +- 2 standard deviation, -62.7 +- 18.4 %), free wall (30.1 +- 12.4 % - 38.5 +- 8.8 %), inferior wall (40.4 +- 7.8 % - 60.0 +- 21.4 %), septal wall (65.2 +- 17.2 % - 71.1 +- 14.2 %). Above the results, SPECT with Tl-201 can accurately define the normal range of RVMW, and this method is usefull to quantify the degree of ischemia and hypertrophy in RVMW. (author)

  18. Clinical usefulness of 123I-labeled 15-iodophenyl 3-methyl pentadecanoic acid (BMIPP) myocardial SPECT in coronary artery disease

    International Nuclear Information System (INIS)

    Ito, Kazuki

    1998-01-01

    123 I-BMIPP (BMIPP) myocardial SPECT was carried out in 22 patients with acute myocardial infarction, in 20 patients with unstable angina pectoris, in 80 patients with effort angina pectoris and in 25 patients with vasospastic angina pectoris. In a study of patients with acute myocardial infarction, BMIPP uptake was less than thallium perfusion in areas of myocardial infarction. Such discordant BMIPP/thallium uptake was often observed in areas with recanalized arteries, and in those with abnormal wall motion. In the areas showing discordant BMIPP/thallium uptake, the wall motion abnormalities improved in the chronic phase after recanalization therapy. Therefore, the discordant BMIPP/thallium uptake might represent asynergic but viable regions, and might be valuable in predicting the improvement of wall motion abnormalities. In a study of patients with unstable angina pectoris, the severity of regional wall motion abnormality was significantly correlated with severity of BMIPP uptake. BMIPP imaging well visualized the culprit regions in patients with unstable angina pectoris. In a study of patients with effort angina pectoris, the abnormal BMIPP images were associated with severe coronary artery stenosis of more than 90% and with multivessel stenosis. BMIPP imaging could detect patients with functionally severe coronary artery disease and help to guide coronary angioplasty in patients with effort angina. In a study of patients with vasospastic angina pectoris, metabolic abnormality assessed by BMIPP was associated with left ventricular asynergy and spastic regions. Those abnormalities also correlated inversely with the period from the last attack, and improved after medical treatment. (K.H.)

  19. Triangular SPECT system for 3-D total organ volume imaging: Design concept and preliminary imaging results

    International Nuclear Information System (INIS)

    Lim, C.B.; Anderson, J.; Covic, J.

    1985-01-01

    SPECT systems based on 2-D detectors for projection data collection and filtered back-projection image reconstruction have the potential for true 3-D imaging, providing contiguous slice images in any orientation. Anger camera-based SPECT systems have the natural advantage supporting planar imaging clinical procedures. However, current systems suffer from two drawbacks; poor utilization of emitted photons, and inadequate system design for SPECT. A SPECT system consisting of three rectangular cameras with radial translation would offer the variable cylindrical FOV of 25 cm to 40 cm diameter allowing close detector access to the object. This system would provide optimized imaging for both brain and body organs in terms of sensitivity and resolution. For brain imaging a tight detector triangle with fan beam collimation, matching detector UFOV to the head, allows full 2 π utilization of emitted photons, resulting in >4 times sensitivity increase over the single detector system. Minification of intrinsic detector resolution in fan beam collimation further improves system resolution. For body organ imaging the three detectors with parallel hole collimators, rotating in non-circular orbit, provide both improved resolution and three-fold sensitivity increase. Practical challenges lie in ensuring perfect image overlap from three detectors without resolution degradation and artifact generation in order to benefit from the above improvements. An experimental system has been developed to test the above imaging concept and we have successfully demonstrated the superior image quality of the overlapped images. Design concept will be presented with preliminary imaging results

  20. Prognostic importance of silent myocardial ischemia detected by intravenous dipyridamole thallium myocardial imaging in asymptomatic patients with coronary artery disease

    International Nuclear Information System (INIS)

    Younis, L.T.; Byers, S.; Shaw, L.; Barth, G.; Goodgold, H.; Chaitman, B.R.

    1989-01-01

    One hundred seven asymptomatic patients who underwent intravenous dipyridamole thallium imaging were evaluated to determine prognostic indicators of subsequent cardiac events over an average follow-up period of 14 +/- 10 months. Univariate analysis of 18 clinical, scintigraphic and angiographic variables revealed that a reversible thallium defect, a combined fixed and reversible thallium defect, number of segmental thallium defects and extent of coronary artery disease were significant predictors of subsequent cardiac events. Of the 13 patients who died or had a nonfatal infarction, 12 had a reversible thallium defect. Stepwise logistic regression analysis selected a reversible thallium defect as the only significant predictor of cardiac events. When death or myocardial infarction was the outcome variable, a combined fixed and reversible thallium defect was the only predictor of outcome. In patients without previous myocardial infarction, the cardiac event rate was significantly greater in those with an abnormal versus normal thallium scan (55% versus 12%, p less than 0.001). Thus, intravenous dipyridamole thallium scintigraphy is a useful noninvasive test to risk stratify asymptomatic patients with coronary artery disease. A reversible thallium defect most likely indicates silent myocardial ischemia in a sizable fraction of patients in this clinical subset and is associated with an unfavorable prognosis

  1. Infective endocarditis detection through SPECT/CT images digital processing

    Science.gov (United States)

    Moreno, Albino; Valdés, Raquel; Jiménez, Luis; Vallejo, Enrique; Hernández, Salvador; Soto, Gabriel

    2014-03-01

    Infective endocarditis (IE) is a difficult-to-diagnose pathology, since its manifestation in patients is highly variable. In this work, it was proposed a semiautomatic algorithm based on SPECT images digital processing for the detection of IE using a CT images volume as a spatial reference. The heart/lung rate was calculated using the SPECT images information. There were no statistically significant differences between the heart/lung rates values of a group of patients diagnosed with IE (2.62+/-0.47) and a group of healthy or control subjects (2.84+/-0.68). However, it is necessary to increase the study sample of both the individuals diagnosed with IE and the control group subjects, as well as to improve the images quality.

  2. Thoracic and abdominal SPECT imaging in systemic amyloidosis in identifying multiorgan involvement

    International Nuclear Information System (INIS)

    Wellman, H.N.; Benson, M.D.; Park, H.M.; Siddiqui, A.R.; Krepshaw, J.D.

    1988-01-01

    Thirty-three patients with systemic amyloidosis have been studied. Thoracic single photon emission computed tomography (SPECT) for myocardial involvement and skeletal imaging were performed with Tc-99m PYP, and abdominal SPECT with TcS colloid. Myocardial wall involvement was easily discernible with SPECT in 17 cases, and in many with normal ultrasonography. PYP uptake was also observed in liver (five patients), kidneys (four patients), and soft tissues (two patients). Most patients had widespread degenerative joint disease. With TcS colloid, intrinsic liver abnormalities were found in four patients, hepatomegaly in seven, and splenic infiltration in two. Nuclear SPECT and planar imaging characterize the distribution of systemic amyloidosis in organs, distribution not readily identified with other diagnostic modalities

  3. Impact of SPECT/CT in imaging inflammation and infection; Wertigkeit der SPECT/CT fuer die nuklearmedizinische Entzuendungsdiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Linke, R. [Klinikum Bremen-Mitte, Bremen (Germany). Klinik fuer Nuklearmedizin; Kuwert, T. [Erlangen-Nuernberg Univ., Erlangen (Germany). Nuklearmedizinische Klinik mit Poliklinik

    2011-03-15

    Even today infection remains a significant concern, and the diagnosis and localization of infectious foci is an important health issue. As an established infection-imaging modality, nuclear medicine plays a vital health-care role in the diagnosis and subsequent effective treatment of this condition. Several techniques in nuclear medicine significantly aid infection diagnosis, including triple-phase bone scanning, {sup 18}F-FDG-PET and imaging with {sup 111}In-oxine-, {sup 99m}Tc-HMPAO-labeled leukocytes. Each radiopharmaceutical has specific advantages and disadvantages that makes it suitable to diagnose different infectious processes (e.g., soft-tissue sepsis, inflammatory bowel disease, osteomyelitis, occult fever, fever of unknown origin, and infections commonly found in immuno-compromised patients). However, their clinical applications may be limited by the relatively low spatial resolution and the lack of anatomic landmarks of a highly specific tracer with only scarce background uptake to use as a framework for orientation. Anatomic imaging modalities such as CT provide a high-quality assessment of structural abnormalities related to infection, but these structural abnormalities may be unspecific. Furthermore, to detect infection before anatomical changes are present, functional imaging could have some advantages over anatomical imaging. Scintigraphic studies have demonstrated high sensitivity and specificity to an infectious process. Diagnosis and precise delineation of infection may be challenging in certain clinical scenarios, rendering decisions concerning further patient management difficult. The SPECT/CT-technology combines the acquisition of SPECT and CT data with the same imaging device enabling perfect overlay of anatomical and functional images. SPECT/CT imaging data has been shown to be beneficial for many clinical settings such as indeterminate findings in bone scintigraphy, orthopaedic disorders, endocrine, and neuroendocrine tumors. Therefore

  4. Two-dimensional filtering of SPECT images using the Metz and Wiener filters

    International Nuclear Information System (INIS)

    King, M.A.; Schwinger, R.B.; Penney, B.C.; Doherty, P.W.

    1984-01-01

    Presently, single photon emission computed tomographic (SPECT) images are usually reconstructed by arbitrarily selecting a one-dimensional ''window'' function for use in reconstruction. A better method would be to automatically choose among a family of two-dimensional image restoration filters in such a way as to produce ''optimum'' image quality. Two-dimensional image processing techniques offer the advantages of a larger statistical sampling of the data for better noise reduction, and two-dimensional image deconvolution to correct for blurring during acquisition. An investigation of two such ''optimal'' digital image restoration techniques (the count-dependent Metz filter and the Wiener filter) was made. They were applied both as two-dimensional ''window'' functions for preprocessing SPECT images, and for filtering reconstructed images. Their performance was compared by measuring image contrast and per cent fractional standard deviation (% FSD) in multiple-acquisitions of the Jaszczak SPECT phantom at two different count levels. A statistically significant increase in image contrast and decrease in % FSD was observed with these techniques when compared to the results of reconstruction with a ramp filter. The adaptability of the techniques was manifested in a lesser % reduction in % FSD at the high count level coupled with a greater enhancement in image contrast. Using an array processor, processing time was 0.2 sec per image for the Metz filter and 3 sec for the Wiener filter. It is concluded that two-dimensional digital image restoration with these techniques can produce a significant increase in SPECT image quality

  5. Evaluation of image reconstruction methods for {sup 123}I-MIBG-SPECT. A rank-order study

    Energy Technology Data Exchange (ETDEWEB)

    Soederberg, Marcus; Mattsson, Soeren; Oddstig, Jenny; Uusijaervi-Lizana, Helena; Leide-Svegborn, Sigrid [Medical Radiation Physics, Dept. of Clinical Sciences Malmoe, Lund Univ., Skaane Univ. Hospital, Malmoe (Sweden)], e-mail: marcus.soderberg@med.lu.se; Valind, Sven; Thorsson, Ola; Garpered, Sabine [Dept. of Clinical Physiology, Skaane Univ. Hospital, Malmoe (Sweden); Prautzsch, Tilmann [Scivis wissenschaftlice Bildverarbeitung GmbH, Goettingen (Germany); Tischenko, Oleg [Research Unit Medical Radiation Physics and Diagnostics (AMSD), Helmholtz Zentrum Muenchen (Germany); German Research Center for Environmental Health, Neuherberg (Germany)

    2012-09-15

    Background: There is an opportunity to improve the image quality and lesion detectability in single photon emission computed tomography (SPECT) by choosing an appropriate reconstruction method and optimal parameters for the reconstruction. Purpose: To optimize the use of the Flash 3D reconstruction algorithm in terms of equivalent iteration (EI) number (number of subsets times the number of iterations) and to compare with two recently developed reconstruction algorithms ReSPECT and orthogonal polynomial expansion on disc (OPED) for application on {sup 123}I-metaiodobenzylguanidine (MIBG)-SPECT. Material and Methods: Eleven adult patients underwent SPECT 4 h and 14 patients 24 h after injection of approximately 200 MBq {sup 123}I-MIBG using a Siemens Symbia T6 SPECT/CT. Images were reconstructed from raw data using the Flash 3D algorithm at eight different EI numbers. The images were ranked by three experienced nuclear medicine physicians according to their overall impression of the image quality. The obtained optimal images were then compared in one further visual comparison with images reconstructed using the ReSPECT and OPED algorithms. Results: The optimal EI number for Flash 3D was determined to be 32 for acquisition 4 h and 24 h after injection. The average rank order (best first) for the different reconstructions for acquisition after 4 h was: Flash 3D{sub 32} > ReSPECT > Flash 3D{sub 64} > OPED, and after 24 h: Flash 3D{sub 16} > ReSPECT > Flash 3D{sub 32} > OPED. A fair level of inter-observer agreement concerning optimal EI number and reconstruction algorithm was obtained, which may be explained by the different individual preferences of what is appropriate image quality. Conclusion: Using Siemens Symbia T6 SPECT/CT and specified acquisition parameters, Flash 3D{sub 32} (4 h) and Flash 3D{sub 16} (24 h), followed by ReSPECT, were assessed to be the preferable reconstruction algorithms in visual assessment of {sup 123}I-MIBG images.

  6. Assessment of the significance of coronary collateral vessel by using thallium-201 myocardial imaging

    International Nuclear Information System (INIS)

    Kanoh, Yasushi; Shiotani, Hideyuki; Fukuzaki, Hisashi; Maeda, Kazumi.

    1988-01-01

    For functional assessment of coronary collateral vessels, twenty-three patients with effort angina pectoris who had total coronary obstruction were studied. The patients were divided depending on the degree of development of collateral vessels into two groups, i.e. good collateral group I (n = 13) and poor collateral group II (n = 10). Thallium-201 scan was performed immediately (Ex-1 image), 20 minutes (Ex-2 image) after exercise and after nitroglycerin administration (NTG image) respectively. In all images, the relative percent activity of thallium-201 in the collateral-dependent ischemic area to the normal myocardium were calculated and were compaired between two groups. Relative percent activities in group I and II were as follows : Ex-1 image ; 75.8 ± 3.5 % vs. 77.2 ± 2.9 % (NS), Ex-2 images ; 85.3 ± 4.5 % vs. 79.3 ± 3.9 % (p < 0.005), NTG image ; 97.3 ± 3.1 % vs. 96.4 ± 5.2 % (NS). From these results, it was elucidated that good collateral induced early partial redistribution in its perfusion area, suggesting that good collateral circulation may provide rapid recovery from myocardial ischemia. (author)

  7. Thallium-201 myocardial imaging during pharmacologic coronary vasodilation: comparison of oral and intravenous administration of dipyridamole

    International Nuclear Information System (INIS)

    Taillefer, R.; Lette, J.; Phaneuf, D.C.; Leveille, J.; Lemire, F.; Essiambre, R.

    1986-01-01

    Although the diagnostic utility of thallium-201 myocardial imaging after dipyridamole infusion is well established, the intravenous form of the drug is not yet commercially available in North America. Fifty patients referred for coronary angiography were prospectively studied. Within a 2 week period, each patient underwent cardiac catheterization and thallium-201 myocardial imaging after both oral and intravenous dipyridamole administration. For the oral protocol, patients were randomly assigned to treatment with either 200 or 400 mg of dipyridamole in tablet form. Coronary artery stenoses of 70% or greater were considered significant. For the 25 patients who received a 200 mg oral dose of dipyridamole, the scintigraphic study showed perfusion defects in 65% of patients with significant coronary artery disease after the oral dose and in 85% of patients after the intravenous dose. For the 25 patients who received a 400 mg oral dose, the sensitivity of the scintigram was 84% after the oral dose and 79% after the intravenous dose. Except for headache and nausea, side effects were less severe and less frequent with oral (either 200 or 400 mg) than with intravenous dipyridamole. Because of the delayed and variable absorption of dipyridamole tablets, the oral studies required a longer period of medical supervision (45 to 60 minutes), and aminophylline was empirically administered after completion of the first set of thallium-201 images. It is concluded from this study that thallium-201 myocardial imaging after coronary vasodilation with a 400 mg oral dose of dipyridamole is a safe, widely available and reliable alternative for the evaluation of coronary artery disease in patients unable to achieve an adequate exercise level on stress testing

  8. Upward creep of the heart: A frequent source of false-positive reversible defects during thallium-201 stress-redistribution SPECT

    International Nuclear Information System (INIS)

    Friedman, J.; Van Train, K.; Maddahi, J.; Rozanski, A.; Prigent, F.; Bietendorf, J.; Waxman, A.; Berman, D.S.

    1989-01-01

    A new cause of artifactual 201 Tl defects on single photon emission computed tomography (SPECT) termed upward creep of the heart is described. In 102 consecutive patients undergoing 201 Tl SPECT, 30 (29%) demonstrated upward creep defined by an upward movement of the heart of greater than or equal to 2 pixels during acquisition. In 45 consecutive patients with a less than 5% likelihood of coronary artery disease, 17 (38%) had upward creep. Of these nine had reversible 201 Tl defects localized to the inferior and basal inferoseptal walls, while none of the 28 without upward creep had defects. The 17 low likelihood patients with upward creep had longer exercise duration and higher peak heart rate than those without upward creep. In five additional low likelihood patients with upward creep in whom imaging was immediately repeated, the upward creep pattern disappeared on the repeated images. After we changed our test protocol to begin imaging 15 min postexercise, only five (14%) of 36 low likelihood patients tested demonstrated upward creep. Upward creep is probably related to a transient increase in mean total lung volume early following exhaustive exercise, resulting in a mean lower position of the diaphragm (and thus the heart) at the beginning of imaging. The frequency of this source of false-positive 201 Tl studies can be reduced by delaying SPECT acquisition until 15 min postexercise

  9. In vivo SPECT reporter gene imaging of regulatory T cells.

    Directory of Open Access Journals (Sweden)

    Ehsan Sharif-Paghaleh

    Full Text Available Regulatory T cells (Tregs were identified several years ago and are key in controlling autoimmune diseases and limiting immune responses to foreign antigens, including alloantigens. In vivo imaging techniques including intravital microscopy as well as whole body imaging using bioluminescence probes have contributed to the understanding of in vivo Treg function, their mechanisms of action and target cells. Imaging of the human sodium/iodide symporter via Single Photon Emission Computed Tomography (SPECT has been used to image various cell types in vivo. It has several advantages over the aforementioned imaging techniques including high sensitivity, it allows non-invasive whole body studies of viable cell migration and localisation of cells over time and lastly it may offer the possibility to be translated to the clinic. This study addresses whether SPECT/CT imaging can be used to visualise the migratory pattern of Tregs in vivo. Treg lines derived from CD4(+CD25(+FoxP3(+ cells were retrovirally transduced with a construct encoding for the human Sodium Iodide Symporter (NIS and the fluorescent protein mCherry and stimulated with autologous DCs. NIS expressing self-specific Tregs were specifically radiolabelled in vitro with Technetium-99m pertechnetate ((99mTcO(4(- and exposure of these cells to radioactivity did not affect cell viability, phenotype or function. In addition adoptively transferred Treg-NIS cells were imaged in vivo in C57BL/6 (BL/6 mice by SPECT/CT using (99mTcO(4(-. After 24 hours NIS expressing Tregs were observed in the spleen and their localisation was further confirmed by organ biodistribution studies and flow cytometry analysis. The data presented here suggests that SPECT/CT imaging can be utilised in preclinical imaging studies of adoptively transferred Tregs without affecting Treg function and viability thereby allowing longitudinal studies within disease models.

  10. Interest of hybrid SPECT-CT imaging for diagnosis of infection

    International Nuclear Information System (INIS)

    Riviere, A.; Farid, K.; Guyot, M.; Jeandot, R.; Allard, M.; Fernandez, P.; Clermont, H. de; Dauchy, F.; Dupon, M.; Fernandez, P.

    2008-01-01

    Single-Photon Emission Computed Tomography-Computerized Tomography (SPECT-CT) is a new hybrid technique which offers new diagnostic capabilities in daily nuclear medicine practice. This technique not only allows to acquire merged anatomic and functional images in the same time, but also, it increases sensitivity and accuracy of SPECT thanks to attenuation and scattering corrections got from transmission data. Until now, SPECT-CT data have been mainly obtained in oncology and cardiology, but now, many authors use it in many scan studies and particularly for infectious diseases. In inflammatory bowel diseases, SPECT-CT seems to increase diagnostic performances and to modify management of many patients. In suspected vascular sepsis, SPECT-CT could increase sensitivity of white blood cell scintigraphy but also its specificity thanks to spatial resolution of CT. In osteo-articular sepsis, SPECT-CT has the advantage to distinguish osteomyelitis from soft tissue infection and to guide biopsies. Nevertheless, in the light of PET-CT works, SPECT-CT development will probably modify nuclear medicine practice and many studies have to be conducted to highlight consensual procedure guidelines. (authors)

  11. Two-dimensional Doppler echocardiographic correlation of dipyridamole-thallium stress testing with isometric handgrip

    International Nuclear Information System (INIS)

    Whitfield, S.; Aurigemma, G.; Pape, L.; Leppo, J.

    1991-01-01

    To determine how frequently new wall-motion abnormalities that are indicative of ischemia accompany thallium redistribution, 47 consecutive patients underwent two-dimensional, echocardiography during routine dipyridamole-thallium stress testing. A secondary aim of the study was to determine whether the addition of isometric handgrip exercises to the standard dipyridamole imaging protocol increased the frequency of wall-motion abnormalities or thallium redistribution. Echocardiograms and thallium scans were independently interpreted, and wall-motion abnormalities that appeared with dipyridamole, handgrip exercise, or both were compared with results of thallium imaging. Five of 24 patients with thallium redistribution had new wall-motion abnormalities, and the extent (number of segments) of thallium redistribution in these five patients was significantly greater than in those who did not have well-motion abnormalities (p less than 0.03). The addition of isometric handgrip exercises to the imaging protocol did not distinguish between patients with and without new wall-motion abnormalities or thallium redistribution. Thus new wall-motion abnormalities infrequently accompany thallium redistribution in routine dipyridamole stress testing in spite of the addition of handgrip exercises, but when new wall-motion abnormalities are present, they are associated with a greater area of thallium redistribution

  12. Assessment of smoking-induced impairment of pulmonary perfusion using three-dimensional SPECT images

    Energy Technology Data Exchange (ETDEWEB)

    Miyasaka, Takashi [Toho Univ., Tokyo (Japan). School of Medicine

    1997-09-01

    The effects of smoking on ventilation-perfusion lung scintigrams were investigated. The subjects comprised 40 healthy males (28 smokers and 12 nonsmokers) without a history of cardiopulmonary disease and with normal chest radiographs. After acquisition of planar images of ventilation lung scintigrams with 370 MBq of {sup 133}Xe gas, planar images and SPECT images of pulmonary perfusion flow were obtained using 185 MBq of {sup 99m}Tc-MAA. Planar imaging showed perfusion defects in only 5 smokers. In contrast, 16 subjects were found to have perfusion defects on SPECT images (p<0.05), indicating the usefulness of SPECT images in detecting minor vascular damage of the lung. Although perfusion defects were common in the smokers (p<0.05), their relationship to the BRINKMAN index was uncertain. The perfusion defects found in the smokers were nonsegmental and commonly involved the right upper lobe. Ventilation scans revealed only delayed washout of {sup 133}Xe in 4 smokers, suggesting that smoking-induced abnormal perfusion on SPECT appears earlier than impaired ventilation on scintigrams. (author)

  13. HMPAO-SPECT during epileptic seizures: Early and late images

    International Nuclear Information System (INIS)

    Overbeck, B.; Gruenwald, F.; Bockisch, A.; Biersack, H.J.; Reinke, U.; Gratz, K.F.

    1990-01-01

    For presurgical evaluation of epilepsy a 44-year old patient with complex-partial seizures underwent HMPAO-SPECT. The morphology of the seizures, the MRI-scan, psychometry and ictal as well as interictal EEGs showed a left temporal origin of the seizures. Early images were obtained 20 min and late images 24 h following injection. On both scans a marked hyperperfusion was observed in the left temporal area. A crossed cerebellar diaschisis was also seen on both SPECTs. It could be shown that during ictal examinations there is no bloodflow-dependent wash-out from brain tissue. (orig.) [de

  14. Improvement of image quality using interpolated projection data estimation method in SPECT

    International Nuclear Information System (INIS)

    Takaki, Akihiro; Soma, Tsutomu; Murase, Kenya; Kojima, Akihiro; Asao, Kimie; Kamada, Shinya; Matsumoto, Masanori

    2009-01-01

    General data acquisition for single photon emission computed tomography (SPECT) is performed in 90 or 60 directions, with a coarse pitch of approximately 4-6 deg for a rotation of 360 deg or 180 deg, using a gamma camera. No data between adjacent projections will be sampled under these circumstances. The aim of the study was to develop a method to improve SPECT image quality by generating lacking projection data through interpolation of data obtained with a coarse pitch such as 6 deg. The projection data set at each individual degree in 360 directions was generated by a weighted average interpolation method from the projection data acquired with a coarse sampling angle (interpolated projection data estimation processing method, IPDE method). The IPDE method was applied to the numerical digital phantom data, actual phantom data and clinical brain data with Tc-99m ethyle cysteinate dimer (ECD). All SPECT images were reconstructed by the filtered back-projection method and compared with the original SPECT images. The results confirmed that streak artifacts decreased by apparently increasing a sampling number in SPECT after interpolation and also improved signal-to-noise (S/N) ratio of the root mean square uncertainty value. Furthermore, the normalized mean square error values, compared with standard images, had similar ones after interpolation. Moreover, the contrast and concentration ratios increased their effects after interpolation. These results indicate that effective improvement of image quality can be expected with interpolation. Thus, image quality and the ability to depict images can be improved while maintaining the present acquisition time and image quality. In addition, this can be achieved more effectively than at present even if the acquisition time is reduced. (author)

  15. Quantitative thallium-201 myocardial imaging in assessing right ventricular pressure in patients with congenital heart defects

    International Nuclear Information System (INIS)

    Rabinovitch, M.; Fischer, K.C.; Treves, S.

    1981-01-01

    Thallium-201 myocardial scintigraphy was performed in patients with congenital heart defects to determine whether, by quantification of right ventricular isotope uptake, one could assess the degree of right ventricular hypertrophy and so predict the level of right ventricular pressure. It is shown that quantitative analysis of myocardial imaging with thallium-201 is of use clinically in patients with congenital heart defects, in assessing the severity of pulmonary stenosis or the presence of pulmonary artery hypertension. (author)

  16. Pixel based statistical analysis of differences between lung SPECT images: methodological aspects

    International Nuclear Information System (INIS)

    Bendada, S.; Rocchisani, J.L.M.; Moretti, J.L.

    2002-01-01

    The statistical parametric mapping method is applied in Neurology for activation studies. We had adapted this powerful method on Lungs SPECT to help for the diagnosis and the follow-up of pulmonary embolism and other lung diseases. The SPECT slices of pairs of examination were normalized thanks to the total acquired counts, reconstruction background subtracted, smoothed and realigned. A parametric image of statistical differences was finally computed. We had thus obtained a 3D image showing regions of improved or altered region under treatment. A tuning of the various parameters could lead to more accurate image. This new approach of lung SPECT processing appears to be a promising useful tool for the physician. (author)

  17. Establishment study of the in vivo imaging analysis with small animal imaging modalities (micro-PET and micro-SPECT/CT) for bio-drug development

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Beomsu; Park, Sanghyeon; Park, Jeonghoon; Jo, Sungkee; Jung, Uhee; Kim, Seolwha; Lee, Yunjong; Choi, Daeseong

    2011-01-15

    In this study, we established the image acquisition and analysis procedures of micro-PET, SPECT/CT using the experimental animal (mouse) for the development of imaging assessment method for the bio-drug. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with {sup 99m}Tc-MDP, DMSA, and {sup 18}F-FDG. SPECT imaging studies using 3 types of pinhole collimators. 5-MWB collimator was used for SPECT image study. To study whole-body distribution, {sup 99m}Tc-MDP SPECT image study was performed. We obtained the fine distribution image. And the CT images was obtained to provide the anatomical information. And then these two types images are fused. To study specific organ uptake, we examined {sup 99}mTc-DMSA SPECT/CT imaging study. We also performed the PET image study using U87MG tumor bearing mice and {sup 18}F-FDG. The overnight fasting, warming and anesthesia with 2% isoflurane pretreatment enhance the tumor image through reducing the background uptake including brown fat, harderian gland and skeletal muscles. Also we got the governmental approval for use of x-ray generator for CT and radioisotopes as sealed and open source. We prepared the draft of process procedure for the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug.

  18. Establishment study of the in vivo imaging analysis with small animal imaging modalities (micro-PET and micro-SPECT/CT) for bio-drug development

    International Nuclear Information System (INIS)

    Jang, Beomsu; Park, Sanghyeon; Park, Jeonghoon; Jo, Sungkee; Jung, Uhee; Kim, Seolwha; Lee, Yunjong; Choi, Daeseong

    2011-01-01

    In this study, we established the image acquisition and analysis procedures of micro-PET, SPECT/CT using the experimental animal (mouse) for the development of imaging assessment method for the bio-drug. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with 99m Tc-MDP, DMSA, and 18 F-FDG. SPECT imaging studies using 3 types of pinhole collimators. 5-MWB collimator was used for SPECT image study. To study whole-body distribution, 99m Tc-MDP SPECT image study was performed. We obtained the fine distribution image. And the CT images was obtained to provide the anatomical information. And then these two types images are fused. To study specific organ uptake, we examined 99 mTc-DMSA SPECT/CT imaging study. We also performed the PET image study using U87MG tumor bearing mice and 18 F-FDG. The overnight fasting, warming and anesthesia with 2% isoflurane pretreatment enhance the tumor image through reducing the background uptake including brown fat, harderian gland and skeletal muscles. Also we got the governmental approval for use of x-ray generator for CT and radioisotopes as sealed and open source. We prepared the draft of process procedure for the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug

  19. Diagnostic evaluation of brain SPECT imaging in diseases of nervous system

    Energy Technology Data Exchange (ETDEWEB)

    Yongsheng, Jiang; Chengmo, Zhu; Jixian, Zhang; Weijia, Tian [Shanghai Second Medical Univ. (China). Ruijing Hospital

    1992-11-01

    The dynamic distributions of home made ECD and the Amersham brain SPECT imaging agent 'Ceretec' in normal person as well as their diagnostic use in diseases of nervous system were investigated. Semi-quantitative analysis combined with direct observation was more accurate for the diagnosis. Aside from cerebrovascular diseases, SPECT brain imaging has its unique value for the diagnosis of transient ischemic attack, Alzheimer disease, multiple ischemic dementia and epilepsy etc.

  20. SPECT/CT image fusion with 99mTc-HYNIC-TOC in the oncological diagnostic

    International Nuclear Information System (INIS)

    Haeusler, F.

    2006-07-01

    Neuroendocrine tumours displaying somatostatin receptors have been successfully visualized with somatostatin receptor imaging. The aim of this retrospective study was to evaluate the value of anatomical-functional image fusion. Image fusion means the combined transmission and emission tomography (computed tomography (CT)) and single-photon emission computed tomography (SPECT) ) and was analyzed in comparison with SPECT and CT alone. Fifty-three patients (30 men and 23 women; mean age 55,9 years; range: 20-82 years) with suspected or known endocrine tumours were studied. The patients were referred to image fusion because of staging of newly diagnosed tumours (14) or biochemically/clinically suspected neuroendocrine tumour (20) or follow-up studies after therapy (19). The patients were studied with SPECT at 2 and 4 hours after injection of 400 MBq of 99mTc-EDDA-HYNIC-Tyr3-octreotide using a dual-detector scintillation camera. The CT was performed on one of the following two days. For both investigations the patients were fixed in an individualized vacuum mattress to guarantee exactly the same position. SPECT and SPECT/CT showed an equivalent scan result in 35 patients (66 %), discrepancies were found in 18 cases (34 %). After image fusion the scan result was true-positive in 27 patients ( 50.9 %) and true-negative in 25 patients (47.2 %). One patient with multiple small liver metastases escaped SPECT as well as image fusion and was so false-negative. The frequency of equivocal and probable lesion characterization was reduced by 11.6% (12 to 0) with PET/CT in comparison with PET or CT alone. The frequency of definite lesion characterization was increased by 11.6% (91 to 103). SPECT/CT affected the clinical management in 21 patients (40 %). The results of this study indicate that SPECT/CT is a valuable tool for the assessment of neuroendocrine tumours. SPECT/CT is better than SPECT or CT alone and it allows a more precise staging and determination of prognosis and

  1. Comparison of technetium 99m methoxy isobutyl isonitrile and thallium 201 for evaluation of coronary artery disease by planar and tomographic methods

    International Nuclear Information System (INIS)

    Kiat, H.; Maddahi, J.; Roy, L.T.; Van Train, K.; Friedman, J.; Resser, K.; Berman, D.S.

    1989-01-01

    To compare stress/rest technetium 99m methoxy isobutyl isonitrile (Tc-MIBI) with stress redistribution thallium 201(T1-201) myocardial perfusion imaging, 36 patients were studied by single photon emission computerized tomography (SPECT) and planar methods. For SPECT, overall sensitivities for identification of patients with coronary artery disease were 93% (14/15) by Tc-MIBI and 80% (12/15) by TI-201 (p = NS). For planar methods, overall sensitivities were 73% (11/15) by both TI-201 and Tc-MIBI. Overall specificity was 75% (3/4 patients with normal coronary arteries) for both tracers with SPECT and Tc-MIBI by planar imaging and was 50% for planar TI-201 (p = NS). The normalcy rates for overall identification of coronary artery disease were determined in 17 patients with a low likelihood of disease. For SPECT, normalcy rates were 100% by Tc-MIBI and 77% by TI-201 (p = NS). For planar, they were 94% by Tc-MIBI and 88% by TI-201 (p = NS). Vessel sensitivities in the 35 stenosed coronary arteries (greater than or equal to 50% stenosis) for SPECT were 87% by Tc-MIBI and 77% by TI-201 (p = NS). For planar, the vessel sensitivities were 60% by Tc-MIBI and 54% by TI-201 (p = NS). For both tracers, the SPECT vessel sensitivities were significantly higher (p less than 0.005) than planar vessel sensitivities. The vessel specificities in 22 coronary vessels with less than 50% stenosis were 86% by SPECT Tc-MIBI and TI-201, 80% by planar Tc-MIBI and 73% by planar TI-201 (p = NS, SPECT vs planar, Tc-MIBI vs TI-201). Regarding myocardial segmental agreement, for the presence of stress defects the agreement was 91% for the 720 SPECT segments and 95% for the 540 planar segments. For severity of stress defects based on semiquantitative visual scoring, the exact agreement was 87% for SPECT and 80% for planar

  2. Thallium kinetics in rat cardiac transplant rejection

    International Nuclear Information System (INIS)

    Barak, J.H.; LaRaia, P.J.; Boucher, C.A.; Fallon, J.T.; Buckley, M.J.

    1988-01-01

    Cardiac transplant rejection is a very complex process involving both cellular and vascular injury. Recently, thallium imaging has been used to assess acute transplant rejection. It has been suggested that changes in thallium kinetics might be a sensitive indicator of transplant rejection. Accordingly, thallium kinetics were assessed in vivo in acute untreated rat heterotopic (cervical) transplant rejection. Male Lewis rats weighing 225-250 g received heterotopic heart transplants from syngeneic Lewis rats (group A; n = 13), or allogeneic Brown Norway rats (group B; n = 11). Rats were imaged serially on the 2nd and the 7th postoperative days. Serial cardiac thallium content was determined utilizing data collected every 150 sec for 2 hr. The data were fit to a monoexponential curve and the decay rate constant (/sec) derived. By day 7 all group B hearts had histological evidence of severe acute rejection, and demonstrated decreased global contraction. Group A hearts showed normal histology and contractility. However, thallium uptakes and washout of the two groups were the same. Peak thallium uptake of group B was +/- 3758 1166 counts compared with 3553 +/- 950 counts in the control group A (P = 0.6395); The 2-hr percentage of washout was 12.1 +/- 1.04 compared with 12.1 +/- 9.3 (P = 1.0000); and the decay constant was -0.00002065 +/- 0.00001799 compared with -0.00002202 +/- 0.00001508 (P = 0.8409). These data indicate that in vivo global thallium kinetics are preserved during mild-to-severe acute transplant rejection. These findings suggest that the complex cellular and extracellular processes of acute rejection limit the usefulness of thallium kinetics in the detection of acute transplant rejection

  3. Comparison of planar images and SPECT with bayesean preprocessing for the demonstration of facial anatomy and craniomandibular disorders

    International Nuclear Information System (INIS)

    Kircos, L.T.; Ortendahl, D.A.; Hattner, R.S.; Faulkner, D.; Taylor, R.L.

    1984-01-01

    Craniomandiublar disorders involving the facial anatomy may be difficult to demonstrate in planar images. Although bone scanning is generally more sensitive than radiography, facial bone anatomy is complex and focal areas of increased or decreased radiotracer may become obscured by overlapping structures in planar images. Thus SPECT appears ideally suited to examination of the facial skeleton. A series of patients with craniomandibular disorders of unknown origin were imaged using 20 mCi Tc-99m MDP. Planar and SPECT (Siemens 7500 ZLC Orbiter) images were obtained four hours after injection. The SPECT images were reconstructed with a filtered back-projection algorithm. In order to improve image contrast and resolution in SPECT images, the rotation views were pre-processed with a Bayesean deblurring algorithm which has previously been show to offer improved contrast and resolution in planar images. SPECT images using the pre-processed rotation views were obtained and compared to the SPECT images without pre-processing and the planar images. TMJ arthropathy involving either the glenoid fossa or the mandibular condyle, orthopedic changes involving the mandible or maxilla, localized dental pathosis, as well as changes in structures peripheral to the facial skeleton were identified. Bayesean pre-processed SPECT depicted the facial skeleton more clearly as well as providing a more obvious demonstration of the bony changes associated with craniomandibular disorders than either planar images or SPECT without pre-processing

  4. [Application of GVF snake model in segmentation of whole body bone SPECT image].

    Science.gov (United States)

    Zhu, Chunmei; Tian, Lianfang; Chen, Ping; Wang, Lifei; Ye, Guangchun; Mao, Zongyuan

    2008-02-01

    Limited by the imaging principle of whole body bone SPECT image, the gray value of bladder area is quite high, which affects the image's brightness, contrast and readability. In the meantime, the similarity between bladder area and focus makes it difficult for some images to be segmented automatically. In this paper, an improved Snake model, GVF Snake, is adopted to automatically segment bladder area, preparing for further processing of whole body bone SPECT images.

  5. Stereotactic imaging for radiotherapy: accuracy of CT, MRI, PET and SPECT

    International Nuclear Information System (INIS)

    Karger, Christian P; Hipp, Peter; Henze, Marcus; Echner, Gernot; Hoess, Angelika; Schad, Lothar; Hartmann, Guenther H

    2003-01-01

    CT, MRI, PET and SPECT provide complementary information for treatment planning in stereotactic radiotherapy. Stereotactic correlation of these images requires commissioning tests to confirm the localization accuracy of each modality. A phantom was developed to measure the accuracy of stereotactic localization for CT, MRI, PET and SPECT in the head and neck region. To this end, the stereotactically measured coordinates of structures within the phantom were compared with their mechanically defined coordinates. For MRI, PET and SPECT, measurements were performed using two different devices. For MRI, T1- and T2-weighted imaging sequences were applied. For each measurement, the mean radial deviation in space between the stereotactically measured and mechanically defined position of target points was determined. For CT, the mean radial deviation was 0.4 ± 0.2 mm. For MRI, the mean deviations ranged between 0.7 ± 0.2 mm and 1.4 ± 0.5 mm, depending on the MRI device and the imaging sequence. For PET, mean deviations of 1.1 ± 0.5 mm and 2.4 ± 0.3 mm were obtained. The mean deviations for SPECT were 1.6 ± 0.5 mm and 2.0 ± 0.6 mm. The phantom is well suited to determine the accuracy of stereotactic localization with CT, MRI, PET and SPECT in the head and neck region. The obtained accuracy is well below the physical resolution for CT, PET and SPECT, and of comparable magnitude for MRI. Since the localization accuracy may be device dependent, results obtained at one device cannot be generalized to others

  6. High-resolution brain SPECT imaging by combination of parallel and tilted detector heads.

    Science.gov (United States)

    Suzuki, Atsuro; Takeuchi, Wataru; Ishitsu, Takafumi; Morimoto, Yuichi; Kobashi, Keiji; Ueno, Yuichiro

    2015-10-01

    To improve the spatial resolution of brain single-photon emission computed tomography (SPECT), we propose a new brain SPECT system in which the detector heads are tilted towards the rotation axis so that they are closer to the brain. In addition, parallel detector heads are used to obtain the complete projection data set. We evaluated this parallel and tilted detector head system (PT-SPECT) in simulations. In the simulation study, the tilt angle of the detector heads relative to the axis was 45°. The distance from the collimator surface of the parallel detector heads to the axis was 130 mm. The distance from the collimator surface of the tilted detector heads to the origin on the axis was 110 mm. A CdTe semiconductor panel with a 1.4 mm detector pitch and a parallel-hole collimator were employed in both types of detector head. A line source phantom, cold-rod brain-shaped phantom, and cerebral blood flow phantom were evaluated. The projection data were generated by forward-projection of the phantom images using physics models, and Poisson noise at clinical levels was applied to the projection data. The ordered-subsets expectation maximization algorithm with physics models was used. We also evaluated conventional SPECT using four parallel detector heads for the sake of comparison. The evaluation of the line source phantom showed that the transaxial FWHM in the central slice for conventional SPECT ranged from 6.1 to 8.5 mm, while that for PT-SPECT ranged from 5.3 to 6.9 mm. The cold-rod brain-shaped phantom image showed that conventional SPECT could visualize up to 8-mm-diameter rods. By contrast, PT-SPECT could visualize up to 6-mm-diameter rods in upper slices of a cerebrum. The cerebral blood flow phantom image showed that the PT-SPECT system provided higher resolution at the thalamus and caudate nucleus as well as at the longitudinal fissure of the cerebrum compared with conventional SPECT. PT-SPECT provides improved image resolution at not only upper but also at

  7. Application of SPECT/CT imaging in the diagnosis of benign diseases

    International Nuclear Information System (INIS)

    Garcheva, M.; Demirev, A.

    2014-01-01

    The application of recently introduced hybrid nuclear medicine methods gains importance in a variety of clinical fields, mainly because of the unique combination between functional and anatomical data provided by those methods and their capability for a precise localization of pathological processes. Single photon emission computed tomography, combined with computed tomography (SPECT/CT) is one of those methods. Its role in nuclear cardiology is important, because it provides quick attenuation correction and calculates the calcium score. In nuclear endocrinology SPECT/CT participates in thyroid and parathyroid examinations, especially in cases, where there is a need for localization of ectopic parathyroid or thyroid tissue. In nuclear pulmonology, one of the best ways to attribute certain changes seen on the SPECT, to the zone of interest on the CT, is to study the fused images obtained from the SPECT/ CT scanner. In cases of suspected infection and inflammation, fused images are indispensable for accurate localization of the involved tissue (structure) and for discrimination between normal/abnormal uptake. Careful reading of the CT component (even low-dose) is related (in 10% of cases) to clinically important incidental findings: effusions, tumors, metastases or lymph node pathology. SPECT/CT increases the specificity of the examinations and improves significantly the localization of pathological processes. It provides additional information, shortens the diagnostic algorithm and influences the extent of surgical procedures. In many hybrid examinations the preferred CT component is a low-dose one, without considerable radiation exposure. The opportunity to combine nuclear medicine techniques and contrast CT images, aiming at better diagnosis needs further development. SPECT/CT provides important additional information and more accurate diagnostics in patients with benign diseases. (authors) Key words: SPECT/CT. BENIGN DISEASES

  8. Myocardial Infarction Area Quantification using High-Resolution SPECT Images in Rats

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Luciano Fonseca Lemos de [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Mejia, Jorge [Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto, SP (Brazil); Carvalho, Eduardo Elias Vieira de; Lataro, Renata Maria; Frassetto, Sarita Nasbine [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Fazan, Rubens Jr.; Salgado, Hélio Cesar [Departamento de Fisiologia, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Galvis-Alonso, Orfa Yineth [Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto, SP (Brazil); Simões, Marcus Vinícius, E-mail: msimoes@fmrp.usp.br [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2013-07-15

    Imaging techniques enable in vivo sequential assessment of the morphology and function of animal organs in experimental models. We developed a device for high-resolution single photon emission computed tomography (SPECT) imaging based on an adapted pinhole collimator. To determine the accuracy of this system for quantification of myocardial infarct area in rats. Thirteen male Wistar rats (250 g) underwent experimental myocardial infarction by occlusion of the left coronary artery. After 4 weeks, SPECT images were acquired 1.5 hours after intravenous injection of 555 MBq of 99mTc-Sestamibi. The tomographic reconstruction was performed by using specially developed software based on the Maximum Likelihood algorithm. The analysis of the data included the correlation between the area of perfusion defects detected by scintigraphy and extent of myocardial fibrosis assessed by histology. The images showed a high target organ/background ratio with adequate visualization of the left ventricular walls and cavity. All animals presenting infarction areas were correctly identified by the perfusion images. There was no difference of the infarct area as measured by SPECT (21.1 ± 21.2%) and by histology (21.7 ± 22.0%; p=0.45). There was a strong correlation between individual values of the area of infarction measured by these two methods. The developed system presented adequate spatial resolution and high accuracy for the detection and quantification of myocardial infarction areas, consisting in a low cost and versatile option for high-resolution SPECT imaging of small rodents.

  9. Gold-195m first-pass radionuclide ventriculography, thallium-201 single-photon emission CT, and 12-lead ECG stress testing as a combined procedure

    International Nuclear Information System (INIS)

    Kipper, S.L.; Ashburn, W.L.; Norris, S.L.; Rimkus, D.S.; Dillon, W.A.

    1985-01-01

    Graded, sequential, rest/exercise, gold-195m, first-pass ventriculography and thallium-201 (Tl-201) single-photon emission computed tomography (SPECT) were performed simultaneously during a single, electrocardiograph-monitored, bicycle stress test in 24 individuals. The technical aspects and logistics involved in performing this combined radionuclide study are stressed in this preliminary report. Fourteen healthy volunteers each had a normal left ventricular ejection fraction and wall-motion response, along with normal T1-201 perfusion and washout, as determined by both visual and quantitative analysis of the tomographic sections. Each of ten patients with coronary artery disease had at least one abnormality of these parameters. The authors suggest that it is technically feasible to evaluate both cardiac function and myocardial perfusion simultaneously by combing Au-195m ventriculography and Tl-201 SPECT imaging into a single, noninvasive, diagnostic package

  10. SPECT/CT imaging in bone scintigraphy of a case of clavicular osteoma

    International Nuclear Information System (INIS)

    Yamamoto, Yuka; Nishiyama, Yoshihiro

    2014-01-01

    Osteoma is a benign bone-forming tumor that usually arises in the craniofacial bones and rarely in the long bones. Clavicular involvement is extremely rare. We report a 51-year-old woman with osteoma of the left clavicle. Radiograph of the left shoulder showed a well-defined lobulated blastic mass in the proximal and mid-portion of the left clavicle. Bone scintigraphy was performed 4 hours after an intravenous injection of Tc-99m hydroxymethylene diphosphonate (HMDP). Whole-body image showed a focus of intensely increased uptake in the clavicle. Single photon emission computed tomography / computed tomography (SPECT/CT) images were also acquired and clearly showed intense uptake at the tumor site. Integrated SPECT/CT imaging supplies both functional and anatomic information about bone the SPECT imaging improves sensitivity compared with planar imaging, the CT imaging provides precise localization of the abnormal uptake, and information on the shape and structure of the abnormalities improves the specificity of the diagnosis

  11. Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging

    International Nuclear Information System (INIS)

    Magota, Keiichi; Kubo, Naoki; Kuge, Yuji; Nishijima, Ken-ichi; Zhao, Songji; Tamaki, Nagara

    2011-01-01

    We investigated the performance of the Inveon small-animal PET/SPECT/CT system and compared the imaging capabilities of the SPECT and PET components. For SPECT, the energy resolution, tomographic spatial resolution and system sensitivity were evaluated with a 99m Tc solution using a single pinhole collimator. For PET, the spatial resolution, absolute sensitivity, scatter fraction and peak noise equivalent count were evaluated. Phantoms and a normal rat were scanned to compare the imaging capabilities of SPECT and PET. The SPECT spatial resolution was 0.84 mm full-width at half-maximum (FWHM) at a radius of rotation of 25 mm using a 0.5-mm pinhole aperture collimator, while the PET spatial resolution was 1.63 mm FWHM at the centre. The SPECT system sensitivity at a radius of rotation of 25 mm was 35.3 cps/MBq (4 x 10 -3 %) using the 0.5-mm pinhole aperture, while the PET absolute sensitivity was 3.2% for 350-650 keV and 3.432 ns. Accordingly, the volume sensitivity of PET was three orders of magnitude higher than that of SPECT. This integrated PET/SPECT/CT system showed high performance with excellent spatial resolution for SPECT and sensitivity for PET. Based on the tracer availability and system performance, SPECT and PET have complementary roles in multimodality small-animal imaging. (orig.)

  12. Usefulness of Thallium Scan for Differential Diagnosis of Breast Mass

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Sang Kyun; Yum, Ha Yong; Lee, Chung Han; Choi, Kyung Hyun [Kosin University College of Medicine, Pusan (Korea, Republic of)

    1994-07-15

    The purpose of this study is to evaluate thallium scanning as a potential test in differentiating malignant from benign lesions of breast. Thirty-one female patients underwent thallium scan of the breast. After intravenous injection of 74-111 MBq(2-3 mCi)of thallium-201, anterior and lateral images were obtained. We compared thallium scans with pathological results. Of 11 patients with breast cancers, 10 cases (90.9%) were detected using thallium scan. Thallium scan obtained in one patient who had breast cancer but received several cycles of chemotherapy did not show thallium uptake. The smallest detectable cancer was 1.5 cm in diameter. In contrast, there is no thallium accumulation in breasts of 17 of 20 patients with benign disease (85%), Three cases of 13 fibrocystic disease show thallium uptake in their breast. In conclusion, thallium scan is an effective test in differentiating benign from malignant lesion.

  13. Usefulness of Thallium Scan for Differential Diagnosis of Breast Mass

    International Nuclear Information System (INIS)

    Bae, Sang Kyun; Yum, Ha Yong; Lee, Chung Han; Choi, Kyung Hyun

    1994-01-01

    The purpose of this study is to evaluate thallium scanning as a potential test in differentiating malignant from benign lesions of breast. Thirty-one female patients underwent thallium scan of the breast. After intravenous injection of 74-111 MBq(2-3 mCi)of thallium-201, anterior and lateral images were obtained. We compared thallium scans with pathological results. Of 11 patients with breast cancers, 10 cases (90.9%) were detected using thallium scan. Thallium scan obtained in one patient who had breast cancer but received several cycles of chemotherapy did not show thallium uptake. The smallest detectable cancer was 1.5 cm in diameter. In contrast, there is no thallium accumulation in breasts of 17 of 20 patients with benign disease (85%), Three cases of 13 fibrocystic disease show thallium uptake in their breast. In conclusion, thallium scan is an effective test in differentiating benign from malignant lesion.

  14. Chest Pain with Normal Thallium-201 Myocardial Perfusion Image – Is It Really Normal?

    Science.gov (United States)

    Liu, Pang-Yen; Lin, Wen-Yu; Lin, Li-Fan; Lin, Chin-Sheng; Lin, Wei-Shiang; Cheng, Shu-Meng; Yang, Shih-Ping; Liou, Jun-Ting

    2016-01-01

    Background Thallium-201 myocardial perfusion image (MPI) is commonly used to detect coronary artery disease in patients with chest pain. Although a normal thallium-201 MPI result is generally considered to be a good prognosis and further coronary angiogram is not recommended, there are still a few patients who suffer from unexpected acute coronary events. The aim of this study was to investigate the clinical prognosis in patients with normal thallium-201 MPI. Methods From January 2006 to August 2012, a total 22,003 patients undergoing thallium-201 MPI in one tertiary center were screened. Of these, 8092 patients had normal results and were investigated retrospectively. During follow-up, 54 patients underwent coronary angiogram because of refractory typical angina pectoris or unexpected acute coronary events. These 54 patients were divided into 2 groups: group I consisted of 26 (48.1%) patients with angiography-proven significant coronary artery stenosis, and group II consisted of 28 (51.9%) patients without significant stenosis. Results Patients in group I had a higher prevalence of prior coronary stenting and electrocardiographic features of ST depression compared with patients in group II. The multivariate analysis demonstrated that both prior coronary stenting and ST depression were risk predictors of unexpected acute coronary events in the patients with normal thallium-201 MPI [odds ratio (OR), 5.93; 95% confidence interval (CI): 1.03-34.06, p = 0.05 and OR, 7.10; 95% CI: 1.28-39.51, p = 0.03,respectively]. Conclusions Although there is a low incidence of unexpected acute coronary events in patients with chest pain and normal thallium-201 MPI, physicians should be aware of the potentials risk in certain patients in this specific population. PMID:27274174

  15. Evaluation of myocardial involvement in Duchenne's progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Sotobata, Iwao; Okada, Mitsuhiro

    1985-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. A qualitative analysis was performed from five projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in the LV posterolateral or posterior wall (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle involvements or thoracic deformities assessed by transmission computed tomography. Extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. Progression of the myocardial scintigraphic abnormalities were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies over 2 to 3 years. It was concluded that thallium myocardial perfusion imaging is a useful clinical technique to assess myocardial involvement in Duchenne's progressive muscular dystrophy. (author)

  16. Diagnosis of Alzheimer's disease using brain perfusion SPECT and MR imaging: which modality achieves better diagnostic accuracy?

    International Nuclear Information System (INIS)

    Kubota, Takao; Ushijima, Yo; Yamada, Kei; Okuyama, Chio; Kizu, Osamu; Nishimura, Tsunehiko

    2005-01-01

    The purpose of this study was to compare the accuracy of MR imaging and brain perfusion single-photon emission tomography (SPECT) in diagnosing Alzheimer's disease (AD). The transaxial section display of brain perfusion SPECT, three-dimensional stereotactic surface projection (3D-SSP) SPECT image sets, thin-section MR imaging of the hippocampus and perfusion MR imaging were evaluated in 66 subjects comprising 35 AD patients and 31 subjects without AD. SPECT and MR imaging were visually interpreted by two experts and two novices, and the diagnostic ability of each modality was evaluated by receiver operating characteristic (ROC) analysis. In the experts' interpretations, there was no significant difference in the area under the ROC curve (A z ) between 3D-SSP and thin-section MR imaging, whereas the A z of transaxial SPECT display was significantly lower than that of 3D-SSP (3D-SSP: 0.97, thin-section MR imaging: 0.96, transaxial SPECT: 0.91), and the A z of perfusion MR imaging was lowest (0.63). The sensitivity and specificity of each modality were, respectively, 80.0% and 96.8% for 3D-SSP, 77.1% and 96.8% for thin-section MR imaging, 60.0% and 93.5% for transaxial SPECT display and 34.3% and 100% for perfusion MR imaging. In the novices' interpretations, the A z , sensitivity and specificity of 3D-SSP were superior to those of thin-section MR imaging. Thin-section hippocampal MR imaging and 3D-SSP image sets had potentially equivalent value for the diagnosis of AD, and they were superior to transaxial SPECT display and perfusion MR imaging. For avoidance of the effect of interpreters' experience on image evaluation, 3D-SSP appears to be optimal. (orig.)

  17. Pseudonormalization of transmitral flow pattern during exercise thallium-201 imaging in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Shiota, Takahiro; Sakamoto, Tsuguya; Takenaka, Katsu; Amano, Keiko; Amano, Wataru; Igarashi, Tsutomu; Otake, Takeshi; Sugimoto, Tsuneaki

    1993-01-01

    This study was undertaken to assess the usefulness of Doppler parameters and transmitral blood velocity for detecting abnormalities of left ventricular diastolic function during low-level exercise thallium-201 imaging. The study population consisted of 16 thallium perfusion defect patients with coronary artery disease (mean 61±8 years) and 21 age-matched control subjects (mean 55±5 years) without any thallium perfusion defect. Of the 16 thallium perfusion defect patients, 12 were examined by coronary arteriography, of whom single vessel coronary artery disease was seen in 2 and multivessel coronary artery disease in 10. Patients with mitral regurgitant murmurs were excluded from the study. Peak mitral blood flow velocity was measured in early diastole (E) and during atrial systole (A) and the A/E ratio was calculated. The changes in blood pressure and heart rate after low-level exercise were not significantly different between control and thallium perfusion defect groups. The A/E ratio increased slightly in control subjects from 93±14% at baseline to 100±15% during low-level exercise (p<0.05), whereas in patients with thallium perfusion defect, it decreased significantly from 119±33% at baseline to 92±23% during low-level exercise (p<0.01). Thus pseudonormalization of the A/E ratio during low-level exercise may be valuable in the evaluation of patients with severe or multivessel coronary artery disease. (author)

  18. Persistent chest pain following oral dipyridamole for thallium 201 myocardial imaging

    International Nuclear Information System (INIS)

    Kwai, A.H.; Jacobson, A.F.; McIntyre, K.M.; Williams, W.H.; Tow, D.E.

    1990-01-01

    A patient was admitted to the hospital with acute chest pain. After acute myocardial infarction was ruled out, he underwent a stress thallium 201 scintigraphy using oral dipyridamole and developed persistent angina with sedimentation time segement elevation. This complication has not been reported previously. It is recommended that appropriate intervention be available if severe ischemia develops following administration of dipyridamole for diagnostic imaging. (orig.)

  19. Safety and diagnostic accuracy of dipyridamole-thallium imaging in the elderly

    International Nuclear Information System (INIS)

    Lam, J.Y.; Chaitman, B.R.; Glaenzer, M.; Byers, S.; Fite, J.; Shah, Y.; Goodgold, H.; Samuels, L.

    1988-01-01

    The noninvasive diagnosis of coronary artery disease in the elderly can occasionally be difficult. Intravenous dipyridamole-thallium imaging is a potentially useful diagnostic test to determine presence and severity of coronary disease; however, the safety of the procedure has not been determined in an older population. The side effect profile and frequency of severe ischemic responses after 0.56 mg/kg of intravenous dipyridamole were compared in 101 patients greater than or equal to 70 years old and 236 patients less than 70 years old. There were no side effects in 64% and 62% of patients greater than or equal to 70 and less than 70 years old, respectively (p = NS). Among the 337 patients tested, there were no complications of myocardial infarction or death. The most common cardiac side effect was chest pain, which occurred in 21 (21%) of the 101 patients aged greater than or equal to 70 years and in 64 (27%) of the 236 patients less than 70 years (p = NS). Aminophylline was required to reverse cardiac or noncardiac side effects in 15 (15%) and 36 (15%) of the patients greater than or equal to 70 and less than 70 years old, respectively (p = NS). A severe ischemic response occurred in 2% and 2.5% of patients greater than or equal to 70 and less than 70 years old, respectively (p = NS). The sensitivity of intravenous dipyridamole-thallium imaging for obstructive coronary artery disease was 86% (25 of 29) and 83% (68 of 82) in older and younger patients, respectively (p = NS); the specificity was 75% (6 of 8) and 70% (16 of 23), respectively (p = NS). Thus, intravenous dipyridamole-thallium imaging is a safe noninvasive method for assessment of older patients with obstructive coronary disease; its side effect profile and diagnostic accuracy are similar to those seen in younger patients. The technique is associated with severe ischemic responses in only a small minority of patients

  20. Starting up stress thallium cardiac imaging services.

    Science.gov (United States)

    Owens, R G; Neubecker, J S

    1992-01-01

    This paper presents an evaluation of alternative methods for a hospital to establish stress thallium cardiac imaging services at a group of physicians' office. Volume-cost-profit analysis, break-even analysis and capital budgeting techniques were used to determine the most feasible method from a financial perspective without sacrificing quality of services. The main focus of this evaluation centers upon three alternative methods of procuring an imaging camera: (1) purchasing a new camera, (2) purchasing used equipment, or (3) leasing a new camera. Budgeted income statements were constructed using relevant revenue and cost information for each alternative. The payback period, net present value and the internal rate of return for each method of procuring a camera was computed. In addition, the break-even point was also determined for each alternative. After the analysis was completed, it was concluded that the method of choice, without sacrificing quality of service delivery, was that of purchasing a used camera.

  1. Visualization of atrial myocardium with thallium-201: case report

    International Nuclear Information System (INIS)

    Cowley, M.J.; Coghlan, H.C.; Logic, J.R.

    1977-01-01

    An adult patient evaluated for cyanotic congenital heart disease was found to have pulmonary atresia with intact ventricular septum, hypoplastic right ventricle, and right atrial enlargement. Thallium-201 myocardial imaging before surgical correction showed thallium activity in the right atrium. Following the establishment of a conduit from the right atrium to pulmonary artery, the right-atrial thallium uptake was even more prominent

  2. Measurement of heterogeneous distribution on technegas SPECT images by three-dimensional fractal analysis

    International Nuclear Information System (INIS)

    Nagao, Michinobu; Murase, Kenya

    2002-01-01

    This review article describes a method for quantifying heterogeneous distribution on Technegas ( 99m Tc-carbon particle radioaerosol) SPECT images by three-dimensional fractal analysis (3D-FA). Technegas SPECT was performed to quantify the severity of pulmonary emphysema. We delineated the SPECT images by using five cut-offs (15, 20, 25, 30 and 35% of the maximal voxel radioactivity), and measured the total number of voxels in the areas surrounded by the contours obtained with each cut-off level. We calculated fractal dimensions from the relationship between the total number of voxels and the cut-off levels transformed into natural logarithms. The fractal dimension derived from 3D-FA is the relative and objective measurement, which can assess the heterogeneous distribution on Technegas SPECT images. The fractal dimension strongly correlate pulmonary function in patients with emphysema and well documented the overall and regional severity of emphysema. (author)

  3. Episodic aphasia associated with tumor active multiple sclerosis: a correlative SPECT study utilising image fusion

    International Nuclear Information System (INIS)

    Roff, G.; Campbell, A.; Lawn, N.; Henderson, A.; McCarthy, M.; Lenzo, N.

    2003-01-01

    Full text: Cerebral perfusion imaging is a common technique to assess cerebral perfusion and metabolism. It can complement anatomical imaging in assessing a number of neurological conditions. At times it can better define the clinical manifestations of a disease process than anatomical imaging alone. We present a clinical case whereby cerebral SPECT imaging helped define the physiological reason for intermittent aphasia in a patient with tumor active multiple sclerotic white matter plaques. Cerebral SPECT studies were performed during a period of aphasia and when the patient had recovered. We utilised subtraction analyses and image fusion techniques to better define the changes seen on SPECT. We discuss the neuroanatomical relationship of aphasia and the automatic fusion technique that allows accurate co-registration of the MRI and SPECT data. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  4. Behaviors of cost functions in image registration between 201Tl brain tumor single-photon emission computed tomography and magnetic resonance images

    International Nuclear Information System (INIS)

    Soma, Tsutomu; Takaki, Akihiro; Teraoka, Satomi; Ishikawa, Yasushi; Murase, Kenya; Koizumi, Kiyoshi

    2008-01-01

    We studied the behaviors of cost functions in the registration of thallium-201 ( 201 Tl) brain tumor single-photon emission computed tomography (SPECT) and magnetic resonance (MR) images, as the similarity index of image positioning. A marker for image registration [technetium-99m ( 99m Tc) point source] was attached at three sites on the heads of 13 patients with brain tumor, from whom 42 sets of 99m Tc- 201 Tl SPECT (the dual-isotope acquisition) and MR images were obtained. The 201 Tl SPECT and MR images were manually registered according to the markers. From the positions where the two images were registered, the position of the 201 Tl SPECT was moved to examine the behaviors of the three cost functions, i.e., ratio image uniformity (RIU), mutual information (MI), and normalized MI (NMI). The cost functions MI and NMI reached the maximum at positions adjacent to those where the SPECT and MR images were manually registered. As for the accuracy of image registration in terms of the cost functions MI and NMI, on average, the images were accurately registered within 3 deg of rotation around the X-, Y-, and Z-axes, and within 1.5 mm (within 2 pixels), 3 mm (within 3 pixels), and 4 mm (within 1 slice) of translation to the X-, Y-, and Z-axes, respectively. In terms of rotation around the Z-axis, the cost function RIU reached the minimum at positions where the manual registration of the two images was substantially inadequate. The MI and NMI were suitable cost functions in the registration of 201 Tl SPECT and MR images. The behavior of the RIU, in contrast, was unstable, being unsuitable as an index of image registration. (author)

  5. Prediction of left ventricular functional recovery in patients with acute myocardial infarction using single photon emission computed tomography with thallium-201 and iodine-123-beta-methyl-p-iodophenyl-pentadecanoic acid

    International Nuclear Information System (INIS)

    Hashimoto, Akiyoshi; Nakata, Tomoaki; Nagao, Kazuhiko

    1995-01-01

    The relationships between myocardial perfusion, fatty acid metabolism, and cardiac function were investigated using dual single photon emission computed tomography (SPECT) with thallium and iodine-123-β-methyl-p-iodophenyl-pentadecanoic acid ( 123 I-BMIPP) during the acute ( 10±1 days) and recovery (60±14 days) phases in 29 patients with acute myocardial infarction. There were 18 patients who underwent successful primary coronary angioplasty (PTCA group) and 11 patients who received conservative therapy (non PTCA group). Thallium and BMIPP uptakes were scored visually by a 4-point system and left ventricular ejection fraction (LVEF) was calculated by radionuclide ventriculography. Although significant positive correlations between thallium and 123 I-BMIPP scores were observed during both phases, BMIPP scores were significantly lower than thallium scores in both acute and recovery phases in the PTCA group. No significant difference in thallium and 123 I-BMIPP scores was observed at the recovery phase in the non PTCA group. LVEF significantly correlated with thallium and 123 I-BMIPP scores in both phases in the PTCA group. Furthermore, the difference between thallium and 123 I-BMIPP scores during the acute phase significantly correlated with the improvement of LVEF during the follow-up period in the PTCA group (y=0.92x-0.77, r=0.65, p 123 I-BMIPP SPECT is increased by reperfusion therapy and persists at least until the recovery phase of myocardial infarction. The recovery of left ventricular function depends on the extent of the mismatched uptake, indicating a predictor for functional recovery following acute myocardial infarction. (author)

  6. A hardware investigation of robotic SPECT for functional and molecular imaging onboard radiation therapy systems

    International Nuclear Information System (INIS)

    Yan, Susu; Tough, MengHeng; Bowsher, James; Yin, Fang-Fang; Cheng, Lin

    2014-01-01

    Purpose: To construct a robotic SPECT system and to demonstrate its capability to image a thorax phantom on a radiation therapy flat-top couch, as a step toward onboard functional and molecular imaging in radiation therapy. Methods: A robotic SPECT imaging system was constructed utilizing a gamma camera detector (Digirad 2020tc) and a robot (KUKA KR150 L110 robot). An imaging study was performed with a phantom (PET CT Phantom TM ), which includes five spheres of 10, 13, 17, 22, and 28 mm diameters. The phantom was placed on a flat-top couch. SPECT projections were acquired either with a parallel-hole collimator or a single-pinhole collimator, both without background in the phantom and with background at 1/10th the sphere activity concentration. The imaging trajectories of parallel-hole and pinhole collimated detectors spanned 180° and 228°, respectively. The pinhole detector viewed an off-centered spherical common volume which encompassed the 28 and 22 mm spheres. The common volume for parallel-hole system was centered at the phantom which encompassed all five spheres in the phantom. The maneuverability of the robotic system was tested by navigating the detector to trace the phantom and flat-top table while avoiding collision and maintaining the closest possible proximity to the common volume. The robot base and tool coordinates were used for image reconstruction. Results: The robotic SPECT system was able to maneuver parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector radius of rotation. Without background, all five spheres were visible in the reconstructed parallel-hole image, while four spheres, all except the smallest one, were visible in the reconstructed pinhole image. With background, three spheres of 17, 22, and 28 mm diameters were readily observed with the parallel-hole imaging, and the targeted spheres (22 and 28 mm diameters) were readily observed in the pinhole

  7. Dual myocardial single photon emission computed tomography (SPECT) using thallium-201 and I-123-β-methyl-i-pentadecanoic acid in patients with Duchenne's progressive muscular dystrophy

    International Nuclear Information System (INIS)

    Shimoyama, Katsuya

    1999-01-01

    Dual single photon emission computed tomography (SPECT) was performed in 31 patients with Duchenne's progressive muscular dystrophy (DMD) using 123 I-β-methyl pentadecanoic acid (BMIPP) for myocardial fatty acid metabolism and 201 thallium (Tl)-chloride for myocardial perfusion. The left ventricle was divided into 9 segments, and accumulation of the radiotracers was assessed visually for each segment to calculate defect score for each tracer. There was some degree of decrease in myocardial accumulation of both tracers in all DMD patients. Reduced accumulation was most common at the apex (BMIPP: 67%, Tl: 63%), followed by the posterior wall, lateral wall, and anterior wall. On the other hand, reduced accumulation was less common at the septum. BMIPP showed a higher accumulation than Tl in all segments but the septum. When BMIPP defect score was larger than Tl defect score, BMIPP defect score tended to increase during 4 years follow-up (p Tl defect score revealed a slight fibrosis or normal myocardium. It can be concluded that the dual SPECT myocardial scintigraphy using BMIPP and Tl provides accurate information about disease progression of the heart in patients with DMD by detecting abnormalities of the myocardial metabolism of each substance, thereby enabling the assessment of left ventricular function. (author)

  8. SPECT and PET Serve as Molecular Imaging Techniques and in Vivo Biomarkers for Brain Metastases

    Science.gov (United States)

    Palumbo, Barbara; Buresta, Tommaso; Nuvoli, Susanna; Spanu, Angela; Schillaci, Orazio; Fravolini, Mario Luca; Palumbo, Isabella

    2014-01-01

    Nuclear medicine techniques (single photon emission computerized tomography, SPECT, and positron emission tomography, PET) represent molecular imaging tools, able to provide in vivo biomarkers of different diseases. To investigate brain tumours and metastases many different radiopharmaceuticals imaged by SPECT and PET can be used. In this review the main and most promising radiopharmaceuticals available to detect brain metastases are reported. Furthermore the diagnostic contribution of the combination of SPECT and PET data with radiological findings (magnetic resonance imaging, MRI) is discussed. PMID:24897023

  9. Thallium-201 myocardial imaging in acute-myocardial infarction

    International Nuclear Information System (INIS)

    Wackers, F.J.Th.; Lie, K.I.; Sokole, E.B.; Wellens, H.J.J.; Samson, G.; Schoot, J.B. van der

    1980-01-01

    Thallium-201 scintigraphy has proven to be an early and highly sensitive technique to detect myocardial perfusion abnormalities in patients with acute myocardial infarction. During the early phase of acute myocardial infarction, patients may be hemodynamically and electrically unstable. Therefore, scintigraphy is performed preferably at the bed side in the Coronary Care Unit using a mobile gamma camera. Additionally, in order to shorten imaging time in these often critically ill patients, the authors recommend injecting no less than 2 mCi of 201 Tl. Using this dosage, the imaging time per view will be approximately five minutes. Routinely, three views are taken: the first view is a supine 45 0 left-anterior-oblique view, followed by a supine anterior view and finally a left-lateral view, the latter with the patient turned on the right side. (Auth.)

  10. Examination of attenuation correction method for cerebral blood Flow SPECT Using MR imaging

    International Nuclear Information System (INIS)

    Mizuno, Takashi; Takahashi, Masaaki

    2009-01-01

    Authors developed a software for attenuation correction using MR imaging (MRAC) (Toshiba Med. System Engineer.) based on the idea that precision of AC could be improved by the head contour in MRI T2-weighted images (T2WI) obtained before 123 I-iofetamine (IMP) single photon emission computed tomography (SPECT) for cerebral blood flow (CBF) measurement. In the present study, this MRAC was retrospectively evaluated by comparison with the previous standard AC methods derived from transmission CT (TCT) and X-CT which overcoming the problem of sinogram threshold Chang method but still having cost and patient exposure issues. MRAC was essentially performed in the Toshiba GMS5500/PI processor where 3D registration was conducted with images of SPECT and MRI of the same patient. The gamma camera for 123 I-IMP SPECT and 99m TcO 4 - TCT was Toshiba 3-detector GCA9300A equipped with the above processor for MRAC and with low energy high resolution (LEHR) fan beam collimator. Machines for MRI and CT were Siemens-Asahi Meditech. MAGNETOM Symphony 1.5T and SOMATOM plus4, respectively. MRAC was examined in 8 patients with images of T1WI, TCT and SPECT, and in 18 of T2WI, CT and SPECT. Evaluation was made by comparison of attenuation coefficients (μ) by the 4 methods. As a result, the present MRAC was found to be closer to AC by TCT and CT than by the Chang method since MRAC, due to exact imaging of the head contour, was independent on radiation count, and was thought to be useful for improving the precision of CBF SPECT. (K.T.)

  11. Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease

    DEFF Research Database (Denmark)

    George, Richard T; Mehra, Vishal C; Chen, Marcus Y

    2014-01-01

    %, respectively, for SPECT. CONCLUSION: The overall performance of myocardial CT perfusion imaging in the diagnosis of anatomic CAD (stenosis ≥50%), as demonstrated with the Az, was higher than that of SPECT and was driven in part by the higher sensitivity for left main and multivessel disease.......PURPOSE: To compare the diagnostic performance of myocardial computed tomographic (CT) perfusion imaging and single photon emission computed tomography (SPECT) perfusion imaging in the diagnosis of anatomically significant coronary artery disease (CAD) as depicted at invasive coronary angiography....... MATERIALS AND METHODS: This study was approved by the institutional review board. Written informed consent was obtained from all patients. Sixteen centers enrolled 381 patients from November 2009 to July 2011. Patients underwent rest and adenosine stress CT perfusion imaging and rest and either exercise...

  12. Nontraumatic femoral head necrosis. Classification of bone scintigraphic findings and diagnostic value of SPECT following planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Minoshima, Satoshi; Uchida, Yoshitaka; Anzai, Yoshimi; Uno, Kimiichi; Arimizu, Noboru [Chiba Univ. (Japan). School of Medicine

    1994-09-01

    This study was conducted to determine bone scintigraphic findings in nontraumatic femoral head avascular necrosis and diagnostic value of SPECT imaging following a conventional planar imaging. Forty-three femoral heads in twenty-six cases with idiopathic femoral head necrosis (n=2), systemic lupus erythematosus (n=22), aplastic anemia (n=1), and renal transplantation (n=1) were studied. The diagnosis for femoral head necrosis was based on magnetic resonance imaging as well as other diagnostic studies in all cases. Scintigraphic findings of planar and SPECT images were classified into six categories: normal (N); cold or decrease (C); partial increase with cold or decrease (PH+C); ring-like increase with a cold center (RH+C); partial increase (PH); diffuse and/or irregular increase (DH). Avascular necrosis was confirmed in twenty-four femoral heads, in which planar and SPECT images showed scintigraphic findings of N (n=3, 2), C (n=1, 3), PH+C (n=2, 8), RH+C (n=2, 3), PH (n=9, 2), and DH (n=7, 6), respectively. Femoral heads without avascular necrosis demonstrated planar and SPECT findings of N (n=16, 12), C (n=0, 6), and DH (n=3, 1), respectively. When considering C, PH+C, and RH+C as diagnostic findings for avascular necrosis, sensitivities of planar and SPECT images were 21% and 58%, and specificities were 100% and 68%, respectively. In nineteen femoral heads with normal planar findings (N), SPECT correctly identified avascular necrosis in two femoral heads and misidentified six normal femoral heads as avascular necrosis. In nineteen femoral heads with nondiagnostic abnormalities (PH, DH), SPECT correctly identified avascular necrosis in seven femoral heads and showed no false positive. Diagnostic planar findings in five femoral heads were concordant with SPECT diagnosis. These results indicate that SPECT imaging is most valuable when planar images show nondiagnostic abnormalities based on the proposed classification of scintigraphic findings. (author).

  13. Nontraumatic femoral head necrosis. Classification of bone scintigraphic findings and diagnostic value of SPECT following planar imaging

    International Nuclear Information System (INIS)

    Minoshima, Satoshi; Uchida, Yoshitaka; Anzai, Yoshimi; Uno, Kimiichi; Arimizu, Noboru

    1994-01-01

    This study was conducted to determine bone scintigraphic findings in nontraumatic femoral head avascular necrosis and diagnostic value of SPECT imaging following a conventional planar imaging. Forty-three femoral heads in twenty-six cases with idiopathic femoral head necrosis (n=2), systemic lupus erythematosus (n=22), aplastic anemia (n=1), and renal transplantation (n=1) were studied. The diagnosis for femoral head necrosis was based on magnetic resonance imaging as well as other diagnostic studies in all cases. Scintigraphic findings of planar and SPECT images were classified into six categories: normal (N); cold or decrease (C); partial increase with cold or decrease (PH+C); ring-like increase with a cold center (RH+C); partial increase (PH); diffuse and/or irregular increase (DH). Avascular necrosis was confirmed in twenty-four femoral heads, in which planar and SPECT images showed scintigraphic findings of N (n=3, 2), C (n=1, 3), PH+C (n=2, 8), RH+C (n=2, 3), PH (n=9, 2), and DH (n=7, 6), respectively. Femoral heads without avascular necrosis demonstrated planar and SPECT findings of N (n=16, 12), C (n=0, 6), and DH (n=3, 1), respectively. When considering C, PH+C, and RH+C as diagnostic findings for avascular necrosis, sensitivities of planar and SPECT images were 21% and 58%, and specificities were 100% and 68%, respectively. In nineteen femoral heads with normal planar findings (N), SPECT correctly identified avascular necrosis in two femoral heads and misidentified six normal femoral heads as avascular necrosis. In nineteen femoral heads with nondiagnostic abnormalities (PH, DH), SPECT correctly identified avascular necrosis in seven femoral heads and showed no false positive. Diagnostic planar findings in five femoral heads were concordant with SPECT diagnosis. These results indicate that SPECT imaging is most valuable when planar images show nondiagnostic abnormalities based on the proposed classification of scintigraphic findings. (author)

  14. SPECT and PET Serve as Molecular Imaging Techniques and in Vivo Biomarkers for Brain Metastases

    Directory of Open Access Journals (Sweden)

    Barbara Palumbo

    2014-06-01

    Full Text Available Nuclear medicine techniques (single photon emission computerized tomography, SPECT, and positron emission tomography, PET represent molecular imaging tools, able to provide in vivo biomarkers of different diseases. To investigate brain tumours and metastases many different radiopharmaceuticals imaged by SPECT and PET can be used. In this review the main and most promising radiopharmaceuticals available to detect brain metastases are reported. Furthermore the diagnostic contribution of the combination of SPECT and PET data with radiological findings (magnetic resonance imaging, MRI is discussed.

  15. Precise fusion of MRI and dual energy 111In WBC/99mTc HDP SPECT/CT in the diabetic foot using companion CT: an example of SPECT/MRI imaging

    International Nuclear Information System (INIS)

    Knešaurek, K.; Heiba, S.; Kolker, D.; Vatti, S.

    2015-01-01

    The purpose of our study was to correctly fuse MRI and SPECT 111 In WBC and 99m Tc HDP images using companion CT images. The fused images could be used to assess proper surgical approach in treatment of the diabetic foot. Nine patients who had dual energy 111 In WBC/ 99 m Tc HDP SPECT/CT and MRI studies within a week were investigated in an ongoing project. A GE Infinia SPECT/CT camera and Siemens MAGNETOM 1.5T MR system were used in this study. First, the MRI and corresponding CT images were coregistrated using a transformation based on normalized mutual information. The transformation was saved and used for MRI and 111 In WBC/ 99 m Tc HDP SPECT fusion. A Jaszczak phantom study was also performed in order to estimate accuracy of MRI/ SPECT fusion. The Jaszczak phantom study with 3.7 MBq 111 In hot sphere showed that MRI/SPECT alignment using the approach described above produced registration with 0.7±0.4 mm accuracy in all three dimensions (3D). The nine clinical cases were visually evaluated and showed 1-2 mm 3D fusion accuracy. MRI provides almost perfect anatomy of soft tissue and bony structures but it may exaggerate the extent of infection. 111 In WBC/ 99 m Tc HDP SPECT imaging is more accurate for infection detection but lacks anatomical reference. Combination of these images proved an essential adjunct to diagnosis. A clinical utility of the approach is illustrated in two clinical examples. In conclusion, the CT in dual energy 111 In WBC/ 99 m Tc HDP SPECT/CT studies can be used to accurately fuse and compare 111 In WBC/ 99 m Tc HDP SPECT and MRI images of the diabetic foot. This can significantly help in conservative treatment planning and limb salvage procedures in treatment of diabetic foot infections.

  16. Preliminary application of brain perfusion SPECT imaging in schizophrenia

    International Nuclear Information System (INIS)

    Wu Zhixing; Guo Chanliu; Li Xingbao; Liang Rongxiang; Zhao Jun; Yan Tingxiu

    1996-01-01

    The clinical value of 99m Tc-ECD brain perfusion SPECT imaging was evaluated in patients with schizophrenia. 32 patients with schizophrenia and 21 normal controls were analyzed with 99m Tc-ECD SPECT. 93.8% (30/32) of the patients showed decreased regional cerebral blood flow (rCBF). There was normal rCBF in controls. In the patient group rCBF decreased significantly in bilateral frontal lobes, left temporal lobe and right basal ganglion. The rCBF of left temporal lobe was significantly lower than that of right temporal lobe. The decreasing rCBF was not significantly related to previous treatment and duration of illness. 99m Tc-ECD SPECT is useful for the study and diagnosis of patients with schizophrenia

  17. Design and evaluation of a mobile bedside PET/SPECT imaging system

    Science.gov (United States)

    Studenski, Matthew Thomas

    Patients confined to an intensive care unit, the emergency room, or a surgical suite are managed without nuclear medicine procedures such as positron emission tomography (PET) or single photon emission computed tomography (SPECT). These studies have diagnostic value which can greatly benefit the physician's treatment of the patient but require that the patient is moved to a scanner. This dissertation examines the feasibility of an economical PET/SPECT system that can be brought to the bedside of an immobile patient for imaging. We chose to focus on cardiac SPECT imaging including perfusion imaging using 99mTc tracers and viability imaging using 18F tracers first because of problems arising from positioning a detector beneath a patient's bed, a requirement for the opposed detector orientation in PET imaging. Second, SPECT imaging acquiring over the anterior 180 degrees of the patient results in reduced attenuation effects due to the heart's location in the anterior portion of the body. Four studies were done to assess the clinical feasibility of the mobile system; 1) the performance of the system was evaluated in SPECT mode at both 140 keV (99mTc tracers) and 511 keV (positron emitting tracers), 2) a dynamic cardiac phantom was used to develop and test image acquisition and processing methods for the system at both energies, 3) a high energy pinhole collimator was designed to reduce the effects of high energy photon penetration through the parallel hole collimator, and 4) we estimated the radiation dose to persons that would be in the vicinity of a patient to ensure that the effective dose is below the regulatory limit. With these studies, we show that the mobile system provides an economical means of bringing nuclear medicine to an immobile patient while staying below the regulatory dose limit to other persons. The system performed well at both 140 keV and 511 keV and provided viable images of a phantom myocardium at both energies. The system does not achieve the

  18. Reversible wall motion abnormality on adenosine stress/rest thallium-201 gated myocardial SPECT is an independent predictor of coronary artery disease

    International Nuclear Information System (INIS)

    Park, Eun Kyung; Lee, Won Woo; So, Young; Eo, Jae Seon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Kim, Sang Eun; Kim, Cheol Ho; Lee, Sang Woo

    2004-01-01

    As early as 10 minutes after adenosine stress, immediate post-stress wall motion (ipsWM) can be evaluated on adenosine stress/rest TI-201 gated SPECT (gSPECT). To widen application of TI-201 in gated SPECT, we investigated image quality, LV parameters (EF, EDV, and ESV) reproducibility, and diagnostic competency of gSPECT regarding ipsWM evaluation Myocardial perfusion and wall motion were evaluated by 5-point scoring system in 20-segment model. Image quality was assessed using weighted Kappa (Kw) for inter-and intra-observer agreements of wall motion scores (n=49). Reproducibility was examined through repeated acquisition (n=31). Diagnostic competency was evaluated versus coronary angiography (CAG) and multivariate logistic regression analysis was performed to identify significant predictors of coronary artery disease (CAD) among stress abnormal perfusion (SSSp), stress abnormal wall motion (SSSwm), and reversible abnormal wall motion (SDSwm) (n=60). Kw for ipsWM was significantly better than that for rest regarding inter- (0.717 vs 0.489) and intra-observer agreements (0.792 vs 0.688) (p<0.05). 2SD for ipsWM was smaller than that for rest at EF (8.6% vs 10.7%) and ESV (6.0ml vs 8.4ml). Sensitivities of SSSp, SSSwm, and SDSwm were 63.3% (19/30), 63.3% (19/30), and 43.3% (13/30) and specificities 83.3% (25/30), 83.3% (25/30), and 86.7% (26/30), respectively. By multivariate analysis, SSSp (p=0.013) and SDSwm (p=0.039) remained significant predictors. Additionally, SSSwm or SDSwm could find undetected CAD in 54.5% (6/11) of patients with normal perfusion. TI-201 can be successfully applied to gated SPECT for ipsWM evaluation. Moreover, reversible wall motion abnormality on gSPECT is an independent predictor of significant CAD

  19. Brain perfusion SPECT imaging before and during the acetazolamide test using sup 99m Tc-HMPAO

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Hiroshi; Higashi, Sotaro; Kinuya, Keiko; Tsuji, Shiro; Sumiya, Hisashi; Hisada, Kinichi; Yamashita, Junkoh (Kanazawa Univ. (Japan). School of Medicine)

    1990-05-01

    A new method using brain perfusion {sup 99m}Tc-HMPAO SPECT imaging was developed for evaluating cerebral perfusion reserve by the acetazolamide test with a short period. The first SPECT study was carried out for 13.5 min to obtain SPECT images at the resting state after 3 min postinjection of 555 MBq (15 mCi) of {sup 99m}Tc-HMPAO. At the same time as the start of the first SPECT study, 1 g of acetazolamide was intravenously injected. Immediately after the stop of the 1st SPECT study, 925 MBq (25 mCi) of {sup 99m}Tc-HMPAO from the same vial as in the first study was additionally injected. Three minutes later the second SPECT study was carried out for 10 min. After reconstruction the tomographic images in the first study were subtracted from the images in the second study to obtain those during the acetazolamide test after correction of the time differences in data acquisition between the two studies. This subtraction technique gives independent brain perfusion SPECT images before and during the acetazolamide test. Besides, the regional flow changes during the test were quantitatively analyzed. In conclusion this method seems to be practically useful for evaluating regional brain perfusion before and during drug treatments as a consecutive study with a short period of approximately 30 min. (author).

  20. Serial assessment of myocardial thallium perfusion and fatty acid utilization in spontaneously hypertensive rats

    International Nuclear Information System (INIS)

    Sago, Masayoshi; Nishimura, Tsunehiko

    1989-01-01

    To evaluate the advantage of free fatty acid imaging on the detection of hypertrophied myocardium, we compared sequentially myocardial thallium and BMIPP (15-(p-iodophenyl)-3-(R,S)-methyl pentadecanoic acid) distribution in spontaneously hypertensive rat (SHR) using dual tracer autoradiography and in vivo pin-hole imaging. Autoradiography and pin-hole imaging showed uniform myocardial distribution of BMIPP and thallium within less than 27 weeks age SHR. In 40 weeks age SHR, thallium myocardial distribution showed uniform, however, BMIPP had focal decrease. Quantitative analysis of pin-hole images showed that myocardial BMIPP and thallium uptake ratio decreased according to the ages of SHR. Our data suggest that hypertension is associated with uniform myocardial perfusion and focal alternation in the substrate used for the performance of myocardial work. Based on the above autoradiographic and in vivo pin-hole imagings, I-123 BMIPP imaging may have a potential for early detection on hypertrophic myocardium compared to thallium perfusion in clinically hypertensive patients. (author)

  1. SPECT brain perfusion imaging in mild traumatic brain injury

    International Nuclear Information System (INIS)

    Li Juan; Liu Baojun; Zhao Feng; He Lirong; Xia Yucheng

    2003-01-01

    Objective: To study the clinical value of SPECT brain perfusion imaging after mild traumatic brain injury and to evaluate the mechanism of brain blood flow changes in the brain traumatic symptoms. Methods: SPECT 99 Tc m -ethylene cysteinate dimer (ECD) brain perfusion imaging was performed on 39 patients with normal consciousness and normal computed tomography. The study was performed on 23 patients within 3 months after the accidental injury and on 16 patients at more than 3 months post-injury. The cerebellum was used as the reference site (100% maximum value). Any decrease in cerebral perfusion in cortex or basal ganglia to below 70%, or even to below 50% in the medial temporal lobe, compared to the cerebellar reference was considered abnormal. Results: The results of 23 patients (59%) were abnormal. Among them, 20 patients showed 74 focal lesions with an average of 3.7 per patient (15 studies performed within 3 months and 8 studies performed more than 3 months after injury). The remaining 3 showed diffuse hypoperfusion (two at the early stage and one at more than 3 months after the injury). The 13 abnormal studies performed at the early stage showed 58 lesions (average, 4.5 per patient), whereas there was a reduction to an average of 2.3 per patient in the 7 patients (total 16 lesions) at more than 3 months post-injury. In the 20 patients with focal lesions, mainly the following regions were involved: frontal lobes 43.2% (32/74), basal ganglia 24.3% (18/74) and temporal lobes 17.6% (13/74). Conclusions: 1) SPECT brain perfusion imaging is more sensitive than computed tomography in detecting brain lesions of mild traumatic brain injury. 2) SPECT brain perfusion imaging is more sensitive at early stage than at late stage after injury. 3) The most common complaints were headache, dizziness, memory deficit. The patients without loss of consciousness may present brain hypoperfusion, too. 4) The changes may explain a neurological component of the patient symptoms in

  2. Design and evaluation of corn starch-bonded Rhizophora spp. particleboard phantoms for SPECT/CT imaging

    Science.gov (United States)

    Hamid, Puteri Nor Khatijah Abd; Yusof, Mohd Fahmi Mohd; Aziz Tajuddin, Abd; Hashim, Rokiah; Zainon, Rafidah

    2018-01-01

    The aim of this study was to design and evaluate of corn starch-bonded Rhizophora spp. particleboards as phantom for SPECT/CT imaging. The phantom was designed according to the Jaszczak phantom commonly used in SPECT imaging with dimension of 22 cm diameter and 18 cm length. Six inserts with different diameter were made for insertion of vials filled with 1.6 µCi/ml of 99mTc unsealed source. The particleboard phantom was scanned using SPECT/CT imaging protocol. The contrast of each vial for particleboards phantom were calculated based on the ratio of counts in radionuclide volume and phantom background and compared to Perspex® and water phantom. The results showed that contrast values for each vial in particleboard phantomis near to 1.0 and in good agreement with Perspex® and water phantoms as common phantom materials for SPECT/CT. The paired sample t-test result showed no significant difference of contrast values between images in particleboard phantoms and that in water. The overall results showed the potential of corn starch-bonded Rhizophora spp. as phantom for quality control and dosimetry works in SPECT/CT imaging.

  3. of Hypoxia-Inducible Factor-1α Activity by the Fusion of High-Resolution SPECT and Morphological Imaging Tests

    Directory of Open Access Journals (Sweden)

    Hirofumi Fujii

    2012-01-01

    Full Text Available Purpose. We aimed to clearly visualize heterogeneous distribution of hypoxia-inducible factor 1α (HIF activity in tumor tissues in vivo. Methods. We synthesized of 125I-IPOS, a 125I labeled chimeric protein probe, that would visualize HIF activity. The biodistribution of 125I-IPOS in FM3A tumor-bearing mice was evaluated. Then, the intratumoral localization of this probe was observed by autoradiography, and it was compared with histopathological findings. The distribution of 125I-IPOS in tumors was imaged by a small animal SPECT/CT scanner. The obtained in vivo SPECT-CT fusion images were compared with ex vivo images of excised tumors. Fusion imaging with MRI was also examined. Results. 125I-IPOS well accumulated in FM3A tumors. The intratumoral distribution of 125I-IPOS by autoradiography was quite heterogeneous, and it partially overlapped with that of pimonidazole. High-resolution SPECT-CT fusion images successfully demonstrated the heterogeneity of 125I-IPOS distribution inside tumors. SPECT-MRI fusion images could give more detailed information about the intratumoral distribution of 125I-IPOS. Conclusion. High-resolution SPECT images successfully demonstrated heterogeneous intratumoral distribution of 125I-IPOS. SPECT-CT fusion images, more favorably SPECT-MRI fusion images, would be useful to understand the features of heterogeneous intratumoral expression of HIF activity in vivo.

  4. Enhanced Diagnosis of Coronary Artery Disease in Women by Dobutamine Thallium-201 ST-Segment/Heart Rate Slope and Thallium-201 Myocardial SPECT

    Directory of Open Access Journals (Sweden)

    Dong-Feng Yeih

    2007-10-01

    Conclusion: Dobutamine ST/HR slope is less sensitive and less accurate than Tl-201 SPECT for detecting CAD in women. However, it adds diagnostic benefit to Tl-201 SPECT with only a little extra calculation.

  5. Registration of SPECT, PET and/or X-ray CT images in patients with lung cancer

    International Nuclear Information System (INIS)

    Uemura, K.; Toyama, H.; Miyamoto, T.; Yoshikawa, K.; Mori, Y.

    2002-01-01

    Aim: In order to evaluate the therapeutic gain of heavy ion therapy performed on patients with lung cancer, the regional pulmonary functions and the amount of radio tracer accumulation to the tumor, we are investigated by using the region of interest based on anatomical information obtained from X-ray CT. There are many registration techniques for brain images, but not so much for the other organ images that we have studied registration of chest SPECT, PET and/or X-ray CT images. Materials and Methods: Perfusion, ventilation and blood pool images with Tc 99m labeled radiopharmaceuticals and SPECT, tumor images with 11 C-methionine and PET and X-ray CT scans were performed on several patients with lung cancer before and after heavy ion therapy. The registrations of SPECT-CT, PET-CT and CT-CT were performed by using AMIR (Automatic Multimodality Image Registration), which was developed by Babak et al. for registration of brain images. In a case of SPECT-CT registration, each of the three functional images was registered to the X-ray CT image, and the accuracy of each registration was compared. In the studies of PET-CT registration, the transmission images and X-ray CT images were registered at first, because the 11 C-methionine PET images bear little resemblance to the underlying anatomical images. Next, the emission images were realigned by using the same registration parameters. The X-ray CT images obtained from a single subject at the different time were registered to the first X-ray CT images, respectively. Results: In the SPECT-CT registration, the blood pool-CT registration is the best among three SPECT images in visual inspection by radiologists. In the PET-CT registration, the Transmission-CT registrations got good results. Therefore, Emission-CT registrations also got good results. In the CT-CT registration, the X-ray CT images obtained from a single subject at the different time were superimposed well each other except for lower lobe. As the results, it was

  6. Geometric Calibration and Image Reconstruction for a Segmented Slant-Hole Stationary Cardiac SPECT System.

    Science.gov (United States)

    Mao, Yanfei; Yu, Zhicong; Zeng, Gengsheng L

    2015-06-01

    A dedicated stationary cardiac single-photon emission computed tomography (SPECT) system with a novel segmented slant-hole collimator has been developed. The goal of this paper is to calibrate this new imaging geometry with a point source. Unlike the commercially available dedicated cardiac SPECT systems, which are specialized and can be used only to image the heart, our proposed cardiac system is based on a conventional SPECT system but with a segmented slant-hole collimator replacing the collimator. For a dual-head SPECT system, 2 segmented collimators, each with 7 sections, are arranged in an L-shaped configuration such that they can produce a complete cardiac SPECT image with only one gantry position. A calibration method was developed to estimate the geometric parameters of each collimator section as well as the detector rotation radius, under the assumption that the point source location is calculated using the central-section data. With a point source located off the rotation axis, geometric parameters for each collimator section can be estimated independently. The parameters estimated individually are further improved by a joint objective function that uses all collimator sections simultaneously and incorporates the collimator symmetry information. Estimation results and images reconstructed from estimated parameters are presented for both simulated and real data acquired from a prototype collimator. The calibration accuracy was validated by computer simulations with an error of about 0.1° for the slant angles and about 1 mm for the rotation radius. Reconstructions of a heart-insert phantom did not show any image artifacts of inaccurate geometric parameters. Compared with the detector's intrinsic resolution, the estimation error is small and can be ignored. Therefore, the accuracy of the calibration is sufficient for cardiac SPECT imaging. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  7. Optimization of Butterworth filter for brain SPECT imaging

    International Nuclear Information System (INIS)

    Minoshima, Satoshi; Maruno, Hirotaka; Yui, Nobuharu

    1993-01-01

    A method has been described to optimize the cutoff frequency of the Butterworth filter for brain SPECT imaging. Since a computer simulation study has demonstrated that separation between an object signal and the random noise in projection images in a spatial-frequency domain is influenced by the total number of counts, the cutoff frequency of the Butterworth filter should be optimized for individual subjects according to total counts in a study. To reveal the relationship between the optimal cutoff frequencies and total counts in brain SPECT study, we used a normal volunteer and 99m Tc hexamethyl-propyleneamine oxime (HMPAO) to obtain projection sets with different total counts. High quality images were created from a projection set with an acquisition time of 300-seconds per projection. The filter was optimized by calculating mean square errors from high quality images visually inspecting filtered reconstructed images. Dependence between total counts and optimal cutoff frequencies was clearly demonstrated in a nomogram. Using this nomogram, the optimal cutoff frequency for each study can be estimated from total counts, maximizing visual image quality. The results suggest that the cutoff frequency of Butterworth filter should be determined by referring to total counts in each study. (author)

  8. Evaluating performance of a pixel array semiconductor SPECT system for small animal imaging

    International Nuclear Information System (INIS)

    Kubo, Naoki; Zhao, Songji; Fujiki, Yutaka

    2005-01-01

    Small animal imaging has recently been focused on basic nuclear medicine. We have designed and built a small animal SPECT imaging system using a semiconductor camera and a newly designed collimator. We assess the performance of this system for small object imaging. We employed an MGC 1500 (Acrorad Co.) camera including a CdTe semiconductor. The pixel size was 1.4 mm/pixel. We designed and produced a parallel-hole collimator with 20-mm hole length. Our SPECT system consisted of a semiconductor camera with the subject holder set on an electric rotating stage controlled by a computer. We compared this system with a conventional small animal SPECT system comprising a SPECT-2000H scanner with four Anger type cameras and pinhole collimators. The count rate linearity for estimation of the scatter was evaluated for a pie-chart phantom containing different concentrations of 99m Tc. We measured the full width half maximum (FWHM) of the 99m Tc SPECT line source along with scatter. The system volume sensitivity was examined using a flood source phantom which was 35 mm long with a 32-mm inside diameter. Additionally, an in vivo myocardial perfusion SPECT study was performed with a rat. With regards to energy resolution, the semiconductor camera (5.6%) was superior to the conventional Anger type camera (9.8%). In the count rate linearity evaluation, the regression lines of the SPECT values were y=0.019x+0.031 (r 2 =0.999) for our system and y=0.018x+0.060 (r 2 =0.997) for the conventional system. Thus, the scatter count using the semiconductor camera was less than that using the conventional camera. FWHMs of our system and the conventional system were 2.9±0.1 and 2.0±0.1 mm, respectively. Moreover, the system volume sensitivity of our system [0.51 kcps/(MBq/ml)/cm] was superior to that of the conventional system [0.44 kcps/(MBq/ml)/cm]. Our system provided clear images of the rat myocardium, sufficient for practical use in small animal imaging. Our SPECT system, utilizing a

  9. Assessment of technetium-99m technegas scintigraphy for ventilatory impairment in pulmonary emphysema. Comparison of planar and SPECT images

    International Nuclear Information System (INIS)

    Satoh, Katashi; Tanabe, Masatada; Takahashi, Kazue

    1997-01-01

    Pulmonary emphysema can be diagnosed easily by X-ray CT (CT) as a low attenuation area. Recently Tc-99m-Technegas (Technegas) has been used for ventilation scintigraphy. The present study was undertaken to assess the usefulness of planar and SPECT images by using Technegas scintigraphy in patients with pulmonary emphysema. Technegas scintigraphy, CT and pulmonary function tests were performed in 20 patients (males, age 32-78 years). We classified the findings of Technegas images into 4 grades. Comparing planar and SPECT images of Technegas, more detailed findings were shown by SPECT than by planar images in mild cases (6 cases, 30%). In more severe cases, findings of SPECT and planar images were equivalent (14 cases, 70%). The degree of abnormal findings obtained by SPECT was equivalent to that obtained by CT in severe cases (6 cases, 30%). SPECT should be excluded in advanced stages as indicated by planar images. (author)

  10. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    Energy Technology Data Exchange (ETDEWEB)

    Golestani, Reza; Dierckx, Rudi A.J.O. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Wu, Chao [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Tio, Rene A. [University Medical Center Groningen, Thorax Center, Department of Cardiology, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Zeebregts, Clark J. [University Medical Center Groningen, Department of Surgery, Division of Vascular Surgery, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Petrov, Artiom D. [University of California, Irvine, Division of Cardiology, School of Medicine, Irvine, California (United States); Beekman, Freek J. [University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Section Radiation Detection and Medical Imaging, Delft (Netherlands); MILabs, Utrecht (Netherlands); Boersma, Hendrikus H. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Department of Clinical and Hospital Pharmacy, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Slart, Riemer H.J.A. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands)

    2010-09-15

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  11. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    International Nuclear Information System (INIS)

    Golestani, Reza; Dierckx, Rudi A.J.O.; Wu, Chao; Tio, Rene A.; Zeebregts, Clark J.; Petrov, Artiom D.; Beekman, Freek J.; Boersma, Hendrikus H.; Slart, Riemer H.J.A.

    2010-01-01

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  12. IRIS Toxicological Review of Thallium and Compounds ...

    Science.gov (United States)

    Thallium compounds are used in the semiconductor industry, the manufacture of optic lenses and low-melting glass, low-temperature thermometers, alloys, electronic devices, mercury lamps, fireworks, and imitation germs, and clinically as an imaging agent in the diagnosis of certain tumors. EPA's assessment of noncancer health effects and carcinogenic potential of thallium compounds was last prepared and added to the IRIS database between 1988 and 1990. The IRIS program is preparing an assessment that will incorporate current health effects information available for thallium and compounds, and current risk assessment methods. The IRIS assessment for thallium compounds will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physiochemical and toxicokinetic properties of a chemical, and its toxicity in humans and experimental systems. The assessment will present reference values for the noncancer effects of thallium compounds (RfD and Rfc), and a cancer assessment. The Toxicological Review and IRIS Summary have been subject to Agency review, Interagency review, and external scientific peer review. The final product will reflect the Agency opinion on the overall toxicity of thallium and compounds. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for thallium and compounds. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effec

  13. Patient motion correction for single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Geckle, W.J.; Becker, L.C.; Links, J.M.; Frank, T.

    1986-01-01

    An investigation has been conducted to develop and validate techniques for the correction of projection images in SPECT studies of the myocardium subject to misalignment due to voluntary patient motion. The problem is frequently encountered due to the uncomfortable position the patient must assume during the 30 minutes required to obtain a 180 degree set of projection images. The reconstruction of misaligned projections can lead to troublesome artifacts in reconstructed images and degrade the diagnostic potential of the procedure. Significant improvement in the quality of heart reconstructions has been realized with the implementation of an algorithm to provide detection of and correction for patient motion. Normal, involuntary motion is not corrected for, however, since such movement is below the spatial resolution of the thallium imaging system under study. The algorithm is based on a comparison of the positions of an object in a set of projection images to the known, sinusoidal trajectory of an off-axis fixed point in space. Projection alignment, therefore, is achieved by shifting the position of a point or set of points in a projection image to the sinusoid of a fixed position in space

  14. High-resolution single photon planar and spect imaging of brain and neck employing a system of two co-registered opposed gamma imaging heads

    Science.gov (United States)

    Majewski, Stanislaw [Yorktown, VA; Proffitt, James [Newport News, VA

    2011-12-06

    A compact, mobile, dedicated SPECT brain imager that can be easily moved to the patient to provide in-situ imaging, especially when the patient cannot be moved to the Nuclear Medicine imaging center. As a result of the widespread availability of single photon labeled biomarkers, the SPECT brain imager can be used in many locations, including remote locations away from medical centers. The SPECT imager improves the detection of gamma emission from the patient's head and neck area with a large field of view. Two identical lightweight gamma imaging detector heads are mounted to a rotating gantry and precisely mechanically co-registered to each other at 180 degrees. A unique imaging algorithm combines the co-registered images from the detector heads and provides several SPECT tomographic reconstructions of the imaged object thereby improving the diagnostic quality especially in the case of imaging requiring higher spatial resolution and sensitivity at the same time.

  15. Molecular Imaging of Hydrolytic Enzymes Using PET and SPECT.

    Science.gov (United States)

    Rempel, Brian P; Price, Eric W; Phenix, Christopher P

    2017-01-01

    Hydrolytic enzymes are a large class of biological catalysts that play a vital role in a plethora of critical biochemical processes required to maintain human health. However, the expression and/or activity of these important enzymes can change in many different diseases and therefore represent exciting targets for the development of positron emission tomography (PET) and single-photon emission computed tomography (SPECT) radiotracers. This review focuses on recently reported radiolabeled substrates, reversible inhibitors, and irreversible inhibitors investigated as PET and SPECT tracers for imaging hydrolytic enzymes. By learning from the most successful examples of tracer development for hydrolytic enzymes, it appears that an early focus on careful enzyme kinetics and cell-based studies are key factors for identifying potentially useful new molecular imaging agents.

  16. Left ventricular dilatation and pulmonary thallium uptake after single-photon emission computer tomography using thallium-201 during adenosine-induced coronary hyperemia

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Heo, J.; Nguyen, T.; Lyons, E.; Paugh, E.

    1990-01-01

    This study examined the implications of left ventricular (LV) dilatation and increased pulmonary thallium uptake during adenosine-induced coronary hyperemia. The lung-to-heart thallium ratio in the initial images was significantly higher in patients with coronary artery disease (CAD) than normal subjects; 0.48 +/- 0.16 in 3-vessel disease (n = 16), 0.43 +/- 0.10 in 2-vessel disease (n = 20), 0.43 +/- 0.08 in 1-vessel disease (n = 16) and 0.36 +/- 0.05 in normal subjects (n = 7) (p less than 0.001, 0.09 and 0.06, respectively). There was a significant correlation between the severity and the extent of the perfusion abnormality (determined from the polar maps) and the lung-to-heart thallium ratio (r = 0.51 and 0.52, respectively, p less than 0.0002). There was also a significant correlation between lung thallium washout and lung-to-heart thallium ratio (r = 0.42, p = 0.0009) and peak heart rate (r = -0.49, p less than 0.0001). The LV dilatation was mostly due to an increase in cavity dimension (30% increase) and to a lesser extent (6% increase) due to increase in LV size. (The cavity dimensions were measured from the short-axis slices at the midventricular level in the initial and delayed images). The dilation was seen in patients with CAD but not in the normal subjects. These changes correlated with the extent and severity of the thallium perfusion abnormality. Thus, adenosine-induced coronary hyperemia may cause LV dilation and increased lung thallium uptake on the basis of subendocardial ischemia

  17. Simultaneous thallium-201/technetium-99m pyrophosphate tomography in patients with acute myocardial infarction: comparison of rotational SPECT and seven pinhole tomography

    International Nuclear Information System (INIS)

    Krause, T.; Schuemichen, C.; Beck, A.; Moser, E.; Zeiher, A.

    1992-01-01

    Simultaneous Tl-201/Tc-99m pyrophosphate (PPi) tomography was compared to Tc-99m PPi tomography and rotational SPECT (SPECT) was compared to seven pinhole tomography (9-PHT), respectively, in 19 patients with acute myocardial infarction (AMI). The results were correlated to electrocardiographic and angiographic findings. With Tl-201/Tc-99, PPi, all infarctions were detected and site of infarction was determined, independent of the tomographic technique used. There was no significant difference between the two acquisition techniques 7-PHT and SPECT concerning spatial extent of Tc-99m PPi accumulation and the uptake ratio. However, using only Tc-99m PPi without Tl-201 as anatomical marker, SPECT detected 15/19 infarctions. In 7 of these 15 cases infarction site was correctly determined. 7-PHT detected 11/19 and site was correctly determined in 9/11 infarctions. Myocardial infarctions which failed diagnosis using Tc-99m PPi alone showed significantly smaller spatial extent of Tc-99m PPi accumulation and necrosis to blood pool ratio was lower as assessed by Tl201/Tc-99m PPi tomography. In conclusions, tomography using simultaneous Tl-201/Tc-99m PPi imaging is a reliable technique for diagnosis and localization of AMI. For this reason, results obtained with SPECT and 7-PHT are comparable. Independent of the tomographic technique used, combined imaging is superior to Tc-99m PPi alone without Tl-201 as additional anatomical marker (orig./MG) [de

  18. Dipyridamole thallium-201 single-photon emission computed tomography for prediction of perioperative cardiac events in patients with arteriosclerosis obliterans undergoing vascular surgery

    International Nuclear Information System (INIS)

    Ziyang, Huang; Komori, Sadayoshi; Sawanobori, Takao

    1998-01-01

    The aim of the study was to determine whether or not dipyridamole thallium-201 single-photon emission computed tomography ( 201 Tl-SPECT) has significant additive value for predicting perioperative cardiac events in patients with arteriosclerosis obliterans (ASO) undergoing vascular surgery. Routine preoperative 201 Tl-SPECT was performed in 106 consecutive patients with ASO (age 68±8.9 years; 91 men and 15 women). The frequency of reversible defects in a clinical high-risk group (n=44) was significantly higher than in a low-risk group (n=62; 55% vs 24%, p 201 Tl-SPECT data to clinical risk-stratified patients with ASO allows better prediction of perioperative cardiac events. (author)

  19. The cardiomyopathy in Friedreich's ataxia: isotopic ventriculography and myocardial imaging with thallium-201

    International Nuclear Information System (INIS)

    Therriault, L.; Lamoureux, G.; Cote, M.; Plourde, G.; Lemieux, B.

    1984-01-01

    Myocardial scanning after the intravenous administration of Thallium 201 was used to evaluate regional myocardial perfusion in 14 patients with Friedreich's ataxia. Isotopic ventriculography was also used to assess left ventricular contractility. Myocardial images in patients with Friedreich's ataxia were found to be precociously abnormal irrespective of the degree of neurological impairment or of the severity of myocardial hypertrophy

  20. Small animal SPECT and its place in the matrix of molecular imaging technologies

    International Nuclear Information System (INIS)

    Meikle, Steven R; Kench, Peter; Kassiou, Michael; Banati, Richard B

    2005-01-01

    Molecular imaging refers to the use of non-invasive imaging techniques to detect signals that originate from molecules, often in the form of an injected tracer, and observe their interaction with a specific cellular target in vivo. Differences in the underlying physical principles of these measurement techniques determine the sensitivity, specificity and length of possible observation of the signal, characteristics that have to be traded off according to the biological question under study. Here, we describe the specific characteristics of single photon emission computed tomography (SPECT) relative to other molecular imaging technologies. SPECT is based on the tracer principle and external radiation detection. It is capable of measuring the biodistribution of minute ( -10 molar) concentrations of radio-labelled biomolecules in vivo with sub-millimetre resolution and quantifying the molecular kinetic processes in which they participate. Like some other imaging techniques, SPECT was originally developed for human use and was subsequently adapted for imaging small laboratory animals at high spatial resolution for basic and translational research. Its unique capabilities include (i) the ability to image endogenous ligands such as peptides and antibodies due to the relative ease of labelling these molecules with technetium or iodine (ii) the ability to measure relatively slow kinetic processes (compared with positron emission tomography, for example) due to the long half-life of the commonly used isotopes and (iii) the ability to probe two or more molecular pathways simultaneously by detecting isotopes with different emission energies. In this paper, we review the technology developments and design tradeoffs that led to the current state-of-the-art in SPECT small animal scanning and describe the position SPECT occupies within the matrix of molecular imaging technologies. (topical review)

  1. SPECT imaging of 131I (364 keV): importance of collimation

    International Nuclear Information System (INIS)

    Clarke, L.P.; Saw, C.B.; Leong, L.K.; Serafini, A.N.

    1985-01-01

    A low sensitivity medium energy collimator (LSMEC) designed with thick septa and long bore (theoretical leakage 131 I for a SPECT system operated in both planar and tomographic imaging modes. The collimator was designed to minimize the influence of photon penetration on spatial resolution, in particular the resolution index FWTM. Overall spatial resolution for the planar imaging mode at 10 cm from the collimator face was found to be 11.6 mm FWHM and 21.6 mm FWTM. The corresponding transverse plane and slice thickness resolution was of the order of 17 mm FWHM and 31 mm FWTM, for a radius of rotation of 16 cm. A SPECT resolution phantom was imaged. Two quadrants of cold rods were well resolved, with rod dimensions of 16 and 12.7 mm respectively, the resolution being comparable to that obtained using 99 Tcsup(m) (140 keV) and a low-energy high-resolution collimator. NEMA sensitivity obtained was 75 cpm/μCi 131 I. The resolution measurements obtained suggest that this collimator should be useful for SPECT imaging with 131 I in either radioimmunoimaging or radioimmunotherapy. (author)

  2. SPECT in psychiatry. SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Barocka, A. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Feistel, H. (Nuklearmedizinische Klinik, Erlangen (Germany)); Ebert, D. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Lungershausen, E. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany))

    1993-08-13

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D[sub 2] and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.)

  3. GATE simulation of a new design of pinhole SPECT system for small animal brain imaging

    International Nuclear Information System (INIS)

    Ozsahin, D. Uzun; Bläckberg, L.; Fakhri, G. El; Sabet, H.

    2017-01-01

    Small animal SPECT imaging has gained an increased interest over the past decade since it is an excellent tool for developing new drugs and tracers. Therefore, there is a huge effort on the development of cost-effective SPECT detectors with high capabilities. The aim of this study is to simulate the performance characteristics of new designs for a cost effective, stationary SPECT system dedicated to small animal imaging with a focus on mice brain. The conceptual design of this SPECT system platform, Stationary Small Animal SSA-SPECT, is to use many pixelated CsI:TI detector modules with 0.4 mm × 0.4 mm pixels in order to achieve excellent intrinsic detector resolution where each module is backed by a single pinhole collimator with 0.3 mm hole diameter. In this work, we present the simulation results of four variations of the SSA-SPECT platform where the number of detector modules and FOV size is varied while keeping the detector size and collimator hole size constant. Using the NEMA NU-4 protocol, we performed spatial resolution, sensitivity, image quality simulations followed by a Derenzo-like phantom evaluation. The results suggest that all four SSA-SPECT systems can provide better than 0.063% system sensitivity and < 1.5 mm FWHM spatial resolution without resolution recovery or other correction techniques. Specifically, SSA-SPECT-1 showed a system sensitivity of 0.09% in combination with 1.1 mm FWHM spatial resolution.

  4. Exercise thallium-201 scintigraphy in evaluating aortocoronary bypass surgery

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Haaz, W.; Segal, B.L.; Kane, S.A.

    1981-01-01

    Thirty patients with recurrent symptoms after aortocoronary bypass graft surgery underwent angiography as well as exercise thallium 201 imaging. Exercise imaging has been shown to be highly specific (100 percent in our study) in evaluating patients after bypass surgery. Patients with complete revascularization have normal thallium 201 images. Similarly, exercise-induced defects are seen only in the presence of incomplete revascularization. There are patients, however, with incomplete revascularization with normal exercise images, but these generally limited to the right coronary artery or the diagonal vessels or their grafts

  5. A Silicon SPECT System for Molecular Imaging of the Mouse Brain.

    Science.gov (United States)

    Shokouhi, Sepideh; Fritz, Mark A; McDonald, Benjamin S; Durko, Heather L; Furenlid, Lars R; Wilson, Donald W; Peterson, Todd E

    2007-01-01

    We previously demonstrated the feasibility of using silicon double-sided strip detectors (DSSDs) for SPECT imaging of the activity distribution of iodine-125 using a 300-micrometer thick detector. Based on this experience, we now have developed fully customized silicon DSSDs and associated readout electronics with the intent of developing a multi-pinhole SPECT system. Each DSSD has a 60.4 mm × 60.4 mm active area and is 1 mm thick. The strip pitch is 59 micrometers, and the readout of the 1024 strips on each side gives rise to a detector with over one million pixels. Combining four high-resolution DSSDs into a SPECT system offers an unprecedented space-bandwidth product for the imaging of single-photon emitters. The system consists of two camera heads with two silicon detectors stacked one behind the other in each head. The collimator has a focused pinhole system with cylindrical-shaped pinholes that are laser-drilled in a 250 μm tungsten plate. The unique ability to collect projection data at two magnifications simultaneously allows for multiplexed data at high resolution to be combined with lower magnification data with little or no multiplexing. With the current multi-pinhole collimator design, our SPECT system will be capable of offering high spatial resolution, sensitivity and angular sampling for small field-of-view applications, such as molecular imaging of the mouse brain.

  6. Quality control of analogue to digital conversion circuitry for artefact-free SPECT imaging

    International Nuclear Information System (INIS)

    Gillen, G.J.; Elliott, A.T.

    1992-01-01

    A simple method for the objective, quantitative assessment of analogue to digital conversion (ADC) differential linearity has been developed for SPECT imaging. The analytical approach uses the fact that a differential non-linearity in the ADC will produce a non-uniformity in the digitized image which has a well defined periodicity. This can be most clearly demonstrated in the frequency space domain by determining the Fourier transform of a thick profile which is taken through the centre of a flood field image. The accuracy of the method permits deteriorations in the performance of ADCs to be detected well before significant reductions in SPECT image quality are produced. The availability of a quantitative measure of ADC performance, which can be tested objectively using a simple data acquisition method, is of value in the specification, acceptance testing and general quality control of gamma camera SPECT systems. (author)

  7. Thallium-201 myocardial imaging in young adults with anomalous left coronary artery arising from the pulmonary artery

    International Nuclear Information System (INIS)

    Moodie, D.S.; Cook, S.A.; Gill, C.C.; Napoli, C.A.

    1980-01-01

    Anomalous origin of the left coronary artery from the pulmonary artery (Bland-Garland-White syndrome) may produce myocardial ischemia, infarction, and frequently death in infancy. Some patients, however, develop satisfactory coronary artery collaterals and are relatively asymptomatic into adulthood. Very little is known about their myocardial perfusion patterns. We studied three young adults with this condition using stress thallium-201 myocardial imaging. Electrocardiograms in two patients demonstrated old arterolateral myocardial infarctions. Preoperative stress exercise tests were positive in all three patients. Marked perfusion abnormalities were found in the proximal anterolateral wall in all patients, and one patient also had a posterolateral defect. Postoperatively, all stress tests returned to normal. Thallium imaging demonstrated improvement in ischemic areas, but old scars persisted

  8. Ictal and interictal SPECT imaging of 8 patients with symptomatic partial epilepsy

    International Nuclear Information System (INIS)

    Motooka, Hiromichi

    1993-01-01

    Although epileptic discharges such as spike, spike and wave complex, sharp wave, and sharp and wave complex can be recorded by interictal scalp electroencephalography (EEG) in many patients with epilepsy, recent studies have demonstrated that no epileptic discharges can be recorded by interictal and ictal scalp EEGs in some patients who clinically exhibit epileptic seizures. Accordingly scalp EEG is not always helpful for diagnosing epilepsy or identifying the epileptic foci in the brain in these patients. Recently, studies using single photon emission computed tomography (SPECT) have been performed for patients with epilepsy and evidence that epileptic foci can be identified by changes in the regional cerebral blood flow (rCBF) seen on SPECT scanning have been accumulated. In the present study, therefore, 8 patients with medically intractable partial seizures were simultaneously or independently investigated by the recordings of scalp EEG and SPECT scanning during the interictal and ictal period. N-isopropyl-p[ 123 I]-iodoamphetamine ( 123 I-IMP) was used for SPECT scanning for 7 patients and 99m Tc-d,l-hexamethyl-propyleneamineoxime ( 99m Tc-HMPAO) for 1 patient. An increase in rCBF (hyperperfusion) or decrease in rCBF (hypoperfusion) were found in 4 patients by interictal SPECT imaging and in all patients by ictal SPECT imaging although epileptic discharges were observed in 3 patients by interictal scalp EEG and 5 patients by ictal scalp EEG. The findings of the present study indicate that ictal SPECT scanning is more useful for diagnosing epilepsy and identifying the epileptic foci in the brain than ictal scalp EEG. (author)

  9. Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3-dimensional brain phantom

    International Nuclear Information System (INIS)

    Akamatsu, Mana; Yamashita, Yasuo; Akamatsu, Go; Tsutsui, Yuji; Ohya, Nobuyoshi; Nakamura, Yasuhiko; Sasaki, Masayuki

    2014-01-01

    The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123 I brain SPECT obtained by the hybrid SPECT/CT device. We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray matter, white matter and bone regions. It was filled with 123 I solution (20.1 kBq/mL) in the gray matter region and with K 2 HPO 4 in the bone region. The SPECT/CT data were acquired by the hybrid SPECT/CT device. SPECT images were reconstructed by using filtered back projection with uniform attenuation correction (FBP-uAC), 3D ordered-subsets expectation-maximization with uniform AC (3D-OSEM-uAC) and 3D OSEM with CT-based non-uniform AC (3D-OSEM-CTAC). We evaluated the differences in the radioactivity distributions among these reconstruction methods using a 3D digital phantom, which was developed from CT images of the 3D brain phantom, as a reference. The normalized mean square error (NMSE) and regional radioactivity were calculated to evaluate the similarity of SPECT images to the 3D digital phantom. The NMSE values were 0.0811 in FBP-uAC, 0.0914 in 3D-OSEM-uAC and 0.0766 in 3D-OSEM-CTAC. The regional radioactivity of FBP-uAC was 11.5% lower in the middle cerebral artery territory, and that of 3D-OSEM-uAC was 5.8% higher in the anterior cerebral artery territory, compared with the digital phantom. On the other hand, that of 3D-OSEM-CTAC was 1.8% lower in all brain areas. By using the hybrid SPECT/CT device, the brain SPECT reconstructed by 3D-OSEM with CT attenuation correction can provide an accurate assessment of the distribution of brain radioactivity

  10. Preoperative localization of epileptic foci with SPECT brain perfusion imaging, electrocorticography, surgery and pathology

    International Nuclear Information System (INIS)

    Jia Shaowei; Xu Wengui; Chen Hongyan; Weng Yongmei; Yang Pinghua

    2002-01-01

    Objective: The value of preoperative localization of epileptic foci with SPECT brain perfusion imaging was investigated. Methods: The study population consisted of 23 patients with intractable partial seizures which was difficult to control with anticonvulsant for long period. In order to preoperatively locate the epileptic foci, double SPECT brain perfusion imaging was performed during interictal and ictal stage. The foci were confirmed with electrocorticography (EcoG), surgery and pathology. Results: The author checked with EcoG the foci shown by SPECT, 23 patients had all typical spike discharge. The regions of radioactivity increase in ictal matched with the abnormal electrical activity areas that EcoG showed. The spike wave originated in the corresponding cerebrum cortex instead of hyperplastic and adherent arachnoid or tumor itself. Conclusions: SPECT brain perfusion imaging contributes to distinguishing location, size, perfusion and functioning of epileptogenic foci, and has some directive function on to making out a treatment programme at preoperation

  11. Diagnostic value of transient dilatation of the left ventricle in negative dipyridamole-thallium imaging

    International Nuclear Information System (INIS)

    Seo, Hiromi; Doi, Y.L.; Yonezawa, Yoshihiro; Chikamori, Taishiro; Yamada, Mitsutoshi; Ozawa, Toshio

    1994-01-01

    To evaluate the diagnostic value of a transient dilatation of the left ventricle during dipyridamole-thallium imaging (DTI) for detecting significant coronary artery disease (CAD) in patients with negative DTI results, 81 consecutive patients were studied. Twenty one patients (26%) had CAD and 60 patients had normal coronary anatomy (NCA). The initial/delayed ratio of the left ventricular dimension, which was measured as the distance between the 2 peaks of a count profile curve on a 45deg left anterior oblique planar image, was defined as the dilatation ratio (DR) of the left ventricle. Patients with CAD had a higher incidence of chest pain after dipyridamole infusion (35 vs 13%; p 1.03) when it was greater than the mean +2 standard deviations of the DR in NCA patients. Seventy-six percent of CAD patients had an abnormal DR. A stepwise discriminant analysis revealed that an abnormal DR alone had the same ability to predict CAD (sensitivity 76%, specificity 98%, chi-square 80.9, p 1.03) is a highly specific marker for detecting CAD, even in patients with negative dipyridamole-thallium imaging. (author)

  12. Examination of statistical noise in SPECT image and sampling pitch

    International Nuclear Information System (INIS)

    Takaki, Akihiro; Soma, Tsutomu; Murase, Kenya; Watanabe, Hiroyuki; Murakami, Tomonori; Kawakami, Kazunori; Teraoka, Satomi; Kojima, Akihiro; Matsumoto, Masanori

    2008-01-01

    Statistical noise in single photon emission computed tomography (SPECT) image was examined for its relation with total count and with sampling pitch by simulation and phantom experiment to obtain their projection data under defined conditions. The former SPECT simulation was performed on assumption of a virtual, homogeneous water column (20 cm diameter) as an absorbing mass. In the latter, used were 3D-Hoffman brain phantom (Data Spectrum Corp.) filled with 370 MBq of 99m Tc-pertechnetate solution and a facing 2-detector SPECT machine with a low-energy/high-resolution collimator, E-CAM (Siemens). Projected data by the two methods were reconstructed through the filtered back projection to make each transaxial image. The noise was evaluated by vision, by their root mean square uncertainty calculated from average count and standard deviation (SD) in the region of interest (ROI) defined in reconstructed images and by normalized mean squares calculated from the difference between the reference image obtained with common sampling pitch to and all of obtained slices of, the simulation and phantom. As a conclusion, the pitch was recommended to be set in the machine as to approximating the value calculated by the sampling theorem, though the projection counts per one angular direction were smaller with the same total time of data acquisition. (R.T.)

  13. Performance evaluation of a compact PET/SPECT/CT tri-modality system for small animal imaging applications

    International Nuclear Information System (INIS)

    Wei, Qingyang; Wang, Shi; Ma, Tianyu; Wu, Jing; Liu, Hui; Xu, Tianpeng; Xia, Yan; Fan, Peng; Lyu, Zhenlei; Liu, Yaqiang

    2015-01-01

    PET, SPECT and CT imaging techniques are widely used in preclinical small animal imaging applications. In this paper, we present a compact small animal PET/SPECT/CT tri-modality system. A dual-functional, shared detector design is implemented which enables PET and SPECT imaging with a same LYSO ring detector. A multi-pinhole collimator is mounted on the system and inserted into the detector ring in SPECT imaging mode. A cone-beam CT consisting of a micro focus X-ray tube and a CMOS detector is implemented. The detailed design and the performance evaluations are reported in this paper. In PET imaging mode, the measured NEMA based spatial resolution is 2.12 mm (FWHM), and the sensitivity at the central field of view (CFOV) is 3.2%. The FOV size is 50 mm (∅)×100 mm (L). The SPECT has a spatial resolution of 1.32 mm (FWHM) and an average sensitivity of 0.031% at the center axial, and a 30 mm (∅)×90 mm (L) FOV. The CT spatial resolution is 8.32 lp/mm @10%MTF, and the contrast discrimination function value is 2.06% with 1.5 mm size cubic box object. In conclusion, a compact, tri-modality PET/SPECT/CT system was successfully built with low cost and high performance

  14. TU-A-12A-02: Novel Lung Ventilation Imaging with Single Energy CT After Single Inhalation of Xenon: Comparison with SPECT Ventilation Images

    Energy Technology Data Exchange (ETDEWEB)

    Negahdar, M [Stanford University School of Medicine, Stanford, CA (United States); Yamamoto, T [UC Davis School of Medicine, Sacramento, CA (United States); Shultz, D; Gable, L; Shan, X; Mittra, E; Loo, B; Maxim, P [Stanford University, Stanford, CA (United States); Diehn, M [Stanford University, Palo Alto, CA (United States)

    2014-06-15

    Purpose: We propose a novel lung functional imaging method to determine the spatial distribution of xenon (Xe) gas in a single inhalation as a measure of regional ventilation. We compare Xe-CT ventilation to single-photon emission CT (SPECT) ventilation, which is the current clinical reference. Regional lung ventilation information may be useful for the diagnosis and monitoring of pulmonary diseases such as COPD, radiotherapy planning, and assessing the progression of toxicity after radiation therapy. Methods: In an IRB-approved clinical study, Xe-CT and SPECT ventilation scans were acquired for three patients including one patient with severe emphysema and two lung cancer patients treated with radiotherapy. For Xe- CT, we acquired two breath-hold single energy CT images of the entire lung with inspiration of 100% O2 and a mixture of 70% Xe and 30% O2, respectively. A video biofeedback system was used to achieve reproducible breath-holds. We used deformable image registration to align the breathhold images with each other to accurately subtract them, producing a map of the distribution of Xe as a surrogate of lung ventilation. We divided each lung into twelve parts and correlated the Hounsfield unit (HU) enhancement at each part with the SPECT ventilation count of the corresponding part of the lung. Results: The mean of the Pearson linear correlation coefficient values between the Xe-CT and ventilation SPECT count for all three patients were 0.62 (p<0.01). The Xe-CT image had a higher resolution than SPECT, and did not show central airway deposition artifacts that were present in the SPECT image. Conclusion: We developed a rapid, safe, clinically practical, and potentially widely accessible method for regional lung functional imaging. We demonstrated strong correlations between the Xe-CT ventilation image and SPECT ventilation image as the clinical reference. This ongoing study will investigate more patients to confirm this finding.

  15. TU-A-12A-02: Novel Lung Ventilation Imaging with Single Energy CT After Single Inhalation of Xenon: Comparison with SPECT Ventilation Images

    International Nuclear Information System (INIS)

    Negahdar, M; Yamamoto, T; Shultz, D; Gable, L; Shan, X; Mittra, E; Loo, B; Maxim, P; Diehn, M

    2014-01-01

    Purpose: We propose a novel lung functional imaging method to determine the spatial distribution of xenon (Xe) gas in a single inhalation as a measure of regional ventilation. We compare Xe-CT ventilation to single-photon emission CT (SPECT) ventilation, which is the current clinical reference. Regional lung ventilation information may be useful for the diagnosis and monitoring of pulmonary diseases such as COPD, radiotherapy planning, and assessing the progression of toxicity after radiation therapy. Methods: In an IRB-approved clinical study, Xe-CT and SPECT ventilation scans were acquired for three patients including one patient with severe emphysema and two lung cancer patients treated with radiotherapy. For Xe- CT, we acquired two breath-hold single energy CT images of the entire lung with inspiration of 100% O2 and a mixture of 70% Xe and 30% O2, respectively. A video biofeedback system was used to achieve reproducible breath-holds. We used deformable image registration to align the breathhold images with each other to accurately subtract them, producing a map of the distribution of Xe as a surrogate of lung ventilation. We divided each lung into twelve parts and correlated the Hounsfield unit (HU) enhancement at each part with the SPECT ventilation count of the corresponding part of the lung. Results: The mean of the Pearson linear correlation coefficient values between the Xe-CT and ventilation SPECT count for all three patients were 0.62 (p<0.01). The Xe-CT image had a higher resolution than SPECT, and did not show central airway deposition artifacts that were present in the SPECT image. Conclusion: We developed a rapid, safe, clinically practical, and potentially widely accessible method for regional lung functional imaging. We demonstrated strong correlations between the Xe-CT ventilation image and SPECT ventilation image as the clinical reference. This ongoing study will investigate more patients to confirm this finding

  16. Noninvasive external cardiac pacing for thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Feldman, M.D.; Warren, S.E.; Gervino, E.V.

    1988-01-01

    Improvements in noninvasive external cardiac pacing have led to a technique with reliable electrical capture and tolerable patient discomfort. To assess the use of this modality of pacing in combination with thallium scintigraphy as a noninvasive pacing stress test, we applied simultaneous noninvasive cardiac pacing, hemodynamic monitoring, and thallium-201 scintigraphy in 14 patients undergoing cardiac catheterization for chest pain syndromes. Two patients had normal coronary arteries, while the remaining 12 had significant coronary artery disease. Thallium scintigraphic responses to pacing were compared to routine exercise thallium stress testing in nine of these 14 patients. All patients were noninvasively paced to more than 85% of the age-predicted maximum heart rate. Twelve patients demonstrated reversible thallium defects, which corresponded in 11 cases to significant lesions seen on coronary angiography. Of nine patients who underwent both pacing and exercise thallium stress tests, comparable maximal rate-pressure products were achieved. Moreover, thallium imaging at peak pacing and during delayed views did not differ significantly from exercise thallium scintigraphy. A limiting factor associated with the technique was local patient discomfort, which occurred to some degree in all patients. We conclude that noninvasive external cardiac pacing together with thallium scintigraphy is capable of detecting significant coronary artery disease and may be comparable to routine exercise thallium stress testing. This new modality of stress testing could be useful in patients unable to undergo the exercise required for standard exercise tolerance testing, particularly if improvements in the technology can be found to reduce further the local discomfort

  17. Clinical significance of exercise induced ST segment depression after successful percutaneous transluminal coronary angioplasty

    International Nuclear Information System (INIS)

    Aoki, Toshikazu; Konishi, Tokuji; Futagami, Yasuo

    1989-01-01

    To evaluate the clinical significance of ST segment depression during repeated Treadmill exercise after successful PTCA, Thallium-201 SPECT was performed. The Thallium-201 SPECT was performed before, one week after and 3-6 months after PTCA. All thirty-five patients had one vessel disease and positive Thallium-201 exercise test. During follow-up period for 3-6 months, 11 of 35 patients had persistent ST segment depression. Restenosis of dilated coronary lesion was demonstrated in 6 of 11 patients. In another 3 of 35 patients, exercise induced ST segment depression was disappered during follow-up Treadmill exercise. In 14 patients with persistent or transient ST segment depression after PTCA, Thallium-201 SPECT demonstrated transient ischemia in 5 of 6 patients with restenosis. In other 8 patients without restenosis, SPECT images did not demonstrate myocardial ischemia and coronary arteriographic findings could not verify side branch stenosis or intimal dissection which might cause myocardial ischemia. The etiology of ST segment depression after successful PTCA in one vessel disease is not produced by exercise induced myocardial ischemia but still unknown mechanisms may be present. (author)

  18. Imaging of gene expression in live pancreatic islet cell lines using dual-isotope SPECT.

    Science.gov (United States)

    Tai, Joo Ho; Nguyen, Binh; Wells, R Glenn; Kovacs, Michael S; McGirr, Rebecca; Prato, Frank S; Morgan, Timothy G; Dhanvantari, Savita

    2008-01-01

    We are combining nuclear medicine with molecular biology to establish a sensitive, quantitative, and tomographic method with which to detect gene expression in pancreatic islet cells in vivo. Dual-isotope SPECT can be used to image multiple molecular events simultaneously, and coregistration of SPECT and CT images enables visualization of reporter gene expression in the correct anatomic context. We have engineered pancreatic islet cell lines for imaging with SPECT/CT after transplantation under the kidney capsule. INS-1 832/13 and alphaTC1-6 cells were stably transfected with a herpes simplex virus type 1-thymidine kinase-green fluorescent protein (HSV1-thymidine kinase-GFP) fusion construct (tkgfp). After clonal selection, radiolabel uptake was determined by incubation with 5-(131)I-iodo-1-(2-deoxy-2-fluoro-beta-d-arabinofuranosyl)uracil ((131)I-FIAU) (alphaTC1-6 cells) or (123)I-FIAU (INS-1 832/13 cells). For the first set of in vivo experiments, SPECT was conducted after alphaTC1-6/tkgfp cells had been labeled with either (131)I-FIAU or (111)In-tropolone and transplanted under the left kidney capsule of CD1 mice. Reconstructed SPECT images were coregistered to CT. In a second study using simultaneous acquisition dual-isotope SPECT, INS-1 832/13 clone 9 cells were labeled with (111)In-tropolone before transplantation. Mice were then systemically administered (123)I-FIAU and data for both (131)I and (111)In were acquired simultaneously. alphaTC1-6/tkgfp cells showed a 15-fold greater uptake of (131)I-FIAU, and INS-1/tkgfp cells showed a 12-fold greater uptake of (123)I-FIAU, compared with that of wild-type cells. After transplantation under the kidney capsule, both reporter gene expression and location of cells could be visualized in vivo with dual-isotope SPECT. Immunohistochemistry confirmed the presence of glucagon- and insulin-positive cells at the site of transplantation. Dual-isotope SPECT is a promising method to detect gene expression in and location of

  19. Exercise thallium testing in ventricular preexcitation

    Energy Technology Data Exchange (ETDEWEB)

    Archer, S.; Gornick, C.; Grund, F.; Shafer, R.; Weir, E.K.

    1987-05-01

    Ventricular preexcitation, as seen in Wolff-Parkinson-White syndrome, results in a high frequency of positive exercise electrocardiographic responses. Why this occurs is unknown but is not believed to reflect myocardial ischemia. Exercise thallium testing is often used for noninvasive assessment of coronary artery disease in patients with conditions known to result in false-positive electrocardiographic responses. To assess the effects of ventricular preexcitation on exercise thallium testing, 8 men (aged 42 +/- 4 years) with this finding were studied. No subject had signs or symptoms of coronary artery disease. Subjects exercised on a bicycle ergometer to a double product of 26,000 +/- 2,000 (+/- standard error of mean). All but one of the subjects had at least 1 mm of ST-segment depression. Tests were terminated because of fatigue or dyspnea and no patient had chest pain. Thallium test results were abnormal in 5 patients, 2 of whom had stress defects as well as abnormally delayed thallium washout. One of these subjects had normal coronary arteries on angiography with a negative ergonovine challenge, and both had normal exercise radionuclide ventriculographic studies. Delayed thallium washout was noted in 3 of the subjects with ventricular preexcitation and normal stress images. This study suggests that exercise thallium testing is frequently abnormal in subjects with ventricular preexcitation. Ventricular preexcitation may cause dyssynergy of ventricular activation, which could alter myocardial thallium handling, much as occurs with left bundle branch block. Exercise radionuclide ventriculography may be a better test for noninvasive assessment of coronary artery disease in patients with ventricular preexcitation.

  20. Exercise thallium testing in ventricular preexcitation

    International Nuclear Information System (INIS)

    Archer, S.; Gornick, C.; Grund, F.; Shafer, R.; Weir, E.K.

    1987-01-01

    Ventricular preexcitation, as seen in Wolff-Parkinson-White syndrome, results in a high frequency of positive exercise electrocardiographic responses. Why this occurs is unknown but is not believed to reflect myocardial ischemia. Exercise thallium testing is often used for noninvasive assessment of coronary artery disease in patients with conditions known to result in false-positive electrocardiographic responses. To assess the effects of ventricular preexcitation on exercise thallium testing, 8 men (aged 42 +/- 4 years) with this finding were studied. No subject had signs or symptoms of coronary artery disease. Subjects exercised on a bicycle ergometer to a double product of 26,000 +/- 2,000 (+/- standard error of mean). All but one of the subjects had at least 1 mm of ST-segment depression. Tests were terminated because of fatigue or dyspnea and no patient had chest pain. Thallium test results were abnormal in 5 patients, 2 of whom had stress defects as well as abnormally delayed thallium washout. One of these subjects had normal coronary arteries on angiography with a negative ergonovine challenge, and both had normal exercise radionuclide ventriculographic studies. Delayed thallium washout was noted in 3 of the subjects with ventricular preexcitation and normal stress images. This study suggests that exercise thallium testing is frequently abnormal in subjects with ventricular preexcitation. Ventricular preexcitation may cause dyssynergy of ventricular activation, which could alter myocardial thallium handling, much as occurs with left bundle branch block. Exercise radionuclide ventriculography may be a better test for noninvasive assessment of coronary artery disease in patients with ventricular preexcitation

  1. Clinical features and 123I-FP-CIT SPECT imaging in drug-induced parkinsonism and Parkinson's disease

    International Nuclear Information System (INIS)

    Diaz-Corrales, Francisco J.; Escobar-Delgado, Teresa; Sanz-Viedma, Salome; Garcia-Solis, David; Mir, Pablo

    2010-01-01

    To determine clinical predictors and accuracy of 123 I-FP-CIT SPECT imaging in the differentiation of drug-induced parkinsonism (DIP) and Parkinson's disease (PD). Several clinical features and 123 I-FP-CIT SPECT images in 32 patients with DIP, 25 patients with PD unmasked by antidopaminergic drugs (PDu) and 22 patients with PD without a previous history of antidopaminergic treatment (PDc) were retrospectively evaluated. DIP and PD shared all clinical features except symmetry of parkinsonian signs which was more frequently observed in patients with DIP (46.9%) than in patients with PDu (16.0%, p 123 I-FP-CIT SPECT images were normal in 29 patients with DIP (90.6%) and abnormal in all patients with PD, and this imaging technique showed high levels of accuracy. DIP and PD are difficult to differentiate based on clinical signs. The precision of clinical diagnosis could be reliably enhanced by 123 I-FP-CIT SPECT imaging. (orig.)

  2. Evaluation of myocardial fatty acid metabolism in the area of fill-in after thallium reinjection in patients with prior myocardial infarction

    International Nuclear Information System (INIS)

    Matsunari, Ichiro; Fujino, Susumu; Nishikawa, Takahiro; Ichiyanagi, Kenji; Taki, Junichi; Nakajima, Kenichi; Tonami, Norihisa; Hisada, Kinichi.

    1995-01-01

    Myocardial fatty acid utilization in the area with thallium fill-in after reinjection was assessed using 123 I-labeled 15-(p-iodophenyl) 3R, S-methylpentadecanoic acid (BMIPP). We studied 22 patients with prior myocardial infarction that revealed persistent defects on standard exercise-redistribution thallium imaging. In each patient, exercise-redistribution-reinjection thallium imaging was performed. Within two weeks of the thallium study, resting BMIPP imaging was performed 20 min after injection of BMIPP (148 MBq). Following qualitative analysis of the obtained thallium and BMIPP images, quantitative analysis was performed on the basis of relative regional uptake. Of 199 myocardial segments that showed persistent defects on exercise-redistribution images, 73 segments showed apparent fill-in on the reinjection images (fill-in positive), and the remaining 126 segments did not (fill-in negative). When BMIPP images were compared with the corresponding thallium reinjection images, reduced BMIPP uptake compared with thallium was frequently observed in the area of fill-in positive segments (65 of 73 segments, 89%). Quantitative analysis also showed decrease in BMIPP activity compared to thallium activity in the area of fill-in (49.7±16.1 vs. 65.8±16.0%, p<0.001). In contrast, only 24 of the 126 fill-in negative segments (19%) showed lower BMIPP uptake than thallium. These results suggest that impaired fatty acid utilization in the area of thallium new fill-in after reinjection already exists at resting condition. Thus, BMIPP imaging combined with exercise-redistribution-reinjection thallium imaging provides insights to understanding fatty acid utilization in ischemic but viable myocardium identified by thallium reinjection in patients with prior myocardial infarction. (author)

  3. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs

    International Nuclear Information System (INIS)

    Mejia, J.; Reis, M.A.; Miranda, A.C.C.; Batista, I.R.; Barboza, M.R.F.; Shih, M.C.; Fu, G.; Chen, C.T.; Meng, L.J.; Bressan, R.A.; Amaro, E. Jr

    2013-01-01

    The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s -1 ·MBq -1 were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging 99m Tc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using 99m Tc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity

  4. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs

    Energy Technology Data Exchange (ETDEWEB)

    Mejia, J. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Reis, M.A. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Laboratório Interdisciplinar de Neurociências Clínicas, Departamento de Psiquiatria, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Miranda, A.C.C. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Batista, I.R. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Laboratório Interdisciplinar de Neurociências Clínicas, Departamento de Psiquiatria, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Barboza, M.R.F.; Shih, M.C. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Fu, G. [GE Global Research, Schenectady, NY (United States); Chen, C.T. [Department of Radiology, University of Chicago, Chicago, IL (United States); Meng, L.J. [Department of Nuclear, Plasma and Radiological Engineering, University of Illinois, Urbana-Champaign, IL (United States); Bressan, R.A. [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil); Laboratório Interdisciplinar de Neurociências Clínicas, Departamento de Psiquiatria, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Amaro, E. Jr [Hospital Israelita Albert Einstein, Instituto do Cérebro, São Paulo, SP (Brazil)

    2013-11-06

    The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s{sup -1}·MBq{sup -1} were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging {sup 99m}Tc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using {sup 99m}Tc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.

  5. Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs

    Directory of Open Access Journals (Sweden)

    J. Mejia

    2013-11-01

    Full Text Available The single photon emission microscope (SPEM is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD. Collimators have 300- and 450-µm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 µm and a sensitivity of 21.6 counts·s-1·MBq-1 were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging 99mTc sources. Images of the thyroid, heart, lungs, and bones of mice were registered using 99mTc-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.

  6. Resting functional imaging tools (MRS, SPECT, PET and PCT).

    Science.gov (United States)

    Van Der Naalt, J

    2015-01-01

    Functional imaging includes imaging techniques that provide information about the metabolic and hemodynamic status of the brain. Most commonly applied functional imaging techniques in patients with traumatic brain injury (TBI) include magnetic resonance spectroscopy (MRS), single photon emission computed tomography (SPECT), positron emission tomography (PET) and perfusion CT (PCT). These imaging modalities are used to determine the extent of injury, to provide information for the prediction of outcome, and to assess evidence of cerebral ischemia. In TBI, secondary brain damage mainly comprises ischemia and is present in more than 80% of fatal cases with traumatic brain injury (Graham et al., 1989; Bouma et al., 1991; Coles et al., 2004). In particular, while SPECT measures cerebral perfusion and MRS determines metabolism, PET is able to assess both perfusion and cerebral metabolism. This chapter will describe the application of these techniques in traumatic brain injury separately for the major groups of severity comprising the mild and moderate to severe group. The application in TBI and potential difficulties of each technique is described. The use of imaging techniques in children will be separately outlined. © 2015 Elsevier B.V. All rights reserved.

  7. Feasibility of Stereo-Infrared Tracking to Monitor Patient Motion During Cardiac SPECT Imaging

    OpenAIRE

    Beach, Richard D.; Pretorius, P. Hendrik; Boening, Guido; Bruyant, Philippe P.; Feng, Bing; Fulton, Roger R.; Gennert, Michael A.; Nadella, Suman; King, Michael A.

    2004-01-01

    Patient motion during cardiac SPECT imaging can cause diagnostic imaging artifacts. We investigated the feasibility of monitoring patient motion using the Polaris motion-tracking system. This system uses passive infrared reflection from small spheres to provide real-time position data with vendor stated 0.35 mm accuracy and 0.2 mm repeatability. In our configuration, the Polaris system views through the SPECT gantry toward the patient's head. List-mode event data was temporally synchronized w...

  8. Swimming clusters in thallium-rich liquid caesium-thallium alloys

    NARCIS (Netherlands)

    van der Aart, SA; van der Lugt, W; Badyal, YS; Verkerk, P

    The purpose of the work presented here is to obtain structural information on thallium-rich caesium-thallium alloys by means of neutron diffraction. The alloys exhibit a long-range (>1 nm) superstructure. This range increases with the thallium content. The results are interpreted with the help of a

  9. Multi-centre evaluation of accuracy and reproducibility of planar and SPECT image quantification. An IAEA phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, Brian E. [National Institute of Standards and Technology, Gaithersburg, MD (United States); Grosev, Darko [Univ. Hospital Centre Zagreb (Croatia); Buvat, Irene [Service Hospitalier Frederic Joliot, Paris (France); and others

    2017-08-01

    Accurate quantitation of activity provides the basis for internal dosimetry of targeted radionuclide therapies. This study investigated quantitative imaging capabilities at sites with a variety of experience and equipment and assessed levels of errors in activity quantitation in Single-Photon Emission Computed Tomography (SPECT) and planar imaging. Participants from 9 countries took part in a comparison in which planar, SPECT and SPECT with X ray computed tomography (SPECT-CT) imaging were used to quantify activities of four epoxy-filled cylinders containing {sup 133}Ba, which was chosen as a surrogate for {sup 131}I. The sources, with nominal volumes of 2, 4, 6 and 23 mL, were calibrated for {sup 133}Ba activity by the National Institute of Standards and Technology, but the activity was initially unknown to the participants. Imaging was performed in a cylindrical phantom filled with water. Two trials were carried out in which the participants first estimated the activities using their local standard protocols, and then repeated the measurements using a standardized acquisition and analysis protocol. Finally, processing of the imaging data from the second trial was repeated by a single centre using a fixed protocol. In the first trial, the activities were underestimated by about 15% with planar imaging. SPECT with Chang's first order attenuation correction (Chang-AC) and SPECT-CT overestimated the activity by about 10%. The second trial showed moderate improvements in accuracy and variability. Planar imaging was subject to methodological errors, e.g., in the use of a transmission scan for attenuation correction. The use of Chang-AC was subject to variability from the definition of phantom contours. The project demonstrated the need for training and standardized protocols to achieve good levels of quantitative accuracy and precision in a multicentre setting. Absolute quantification of simple objects with no background was possible with the strictest protocol to

  10. Serial assessment of left ventricular function in various patient groups with Tl-201 gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Wei Lingge; Kadoya, Masumi; Momose, Mitsuhiro; Kurozumi, Masahiro; Matsushita, Tsuyoshi; Yamada, Akira

    2007-01-01

    The present study was performed to assess stress-related left ventricular (LV) function variations in various patient groups and to determine if they were affected by sex or the type of stress experienced. We used thallium (Tl)-201 gated myocardial perfusion single-photon emission computed tomography (SPECT) for the analysis. A total of 270 patients were examined by electrocardiography-gated myocardial perfusion SPECT imaging to assess LV function. After injection of Tl-201 at a dose of 111 MBq at peak stress, SPECT scans were acquired at 10 min (after stress) and 3 h (rest) after injection on a three-headed camera. In the normal perfusion group, the mean LV ejection fraction (LVEF) was significantly higher, and both the end-diastolic volume index (EDVI) and end-systolic volume index (ESVI) were significantly lower in women than in men (P<0.05). Poststress stunning occurred in 29 of 98 patients (30.0%) in the ischemia group and in 42 of 90 patients (46.7%) in the fixed group. There was a significant difference in poststress stunning between bicycle ergometer stress and dipyridamole stress (P<0.05). In patients with normal perfusion, LVEF, EDVI, and ESVI determined by gated Tl-201 SPECT should be corrected for sex. In addition, the influence of the type of stress should be considered when assessing stress-related LV function variations. (author)

  11. Clinical application of SPECT in adrenal imaging with iodine-131 6 beta-iodomethyl-19-norcholesterol

    International Nuclear Information System (INIS)

    Ishimura, J.; Kawanaka, M.; Fukuchi, M.

    1989-01-01

    Forty-one patients with or without adrenocortical disorders were studied to evaluate the clinical usefulness of SPECT in adrenal imaging with I-131 Adosterol. In the SPECT images from this study, all glands with either normally functioning or hyperfunctioning adrenal cortices could be detected, while those glands with hypofunctioning adrenal cortices could not be detected. Particularly in transaxial and sagittal slices, the adrenal gland was identified posteriorly and was clearly distinguished from the gallbladder. In preliminary results using SPECT by a standard method, uptake in 68 detectable glands ranged from 1.7% to 4.9% in four glands with Cushing's syndrome, from 1.1% to 1.3% in seven glands with primary aldosteronism, and were distributed below 1.0% in the remaining glands with normally functioning adrenal cortices. These data show that it is possible to evaluate the adrenocortical functioning status simply by analyzing the SPECT images of the adrenal

  12. First results in postoperative functional imaging of parathyroid tissue with thallium-201-chloride

    International Nuclear Information System (INIS)

    Schwartz, K.D.; Michael, R.; Karsten, U.; Pietsch, P.; Brietzke, W.; Tredt, H.J.; Dabels, J.; Labes, K.

    1984-01-01

    On account of diagnostic uncertainties Se-75-methionine failed to become accepted clinically for detecting parathyroid adenomas. But recent reports in the literature suggested satisfactory results to be achieved with a double-nuclide technique using Thallium-201-chloride for parathyroid imaging. Data of 6 patients were evaluated to shed light on the usefulness of radio-Thallium for postoperative functional imaging of heterotopic parathyroid tissue. Analogous studies using Se-75-methionine had previously been carried out by other authors. Early results suggest the method to have clinical relavance. Four patients with cubital vein parathormone levels that were higher on the grafted versus the ungrafted side were found to have significantly elevated Tl-201 uptake in the region of the surgical scar on the forearm. Two patients with no or little difference in PTH concentrations between the 2 sides showed no or at best some slight activity increase. The place of this method as an alternative to differential cubital vein parathormone assaying still remains to be established. In view of the poor cubital veins of dialysis patients it appears to hold promises for assessing the function of parathyroid grafts in the forearm. (Author)

  13. Effect of exercise supplementation on dipyridamole thallium-201 image quality

    International Nuclear Information System (INIS)

    Stern, S.; Greenberg, I.D.; Corne, R.

    1991-01-01

    To determine the effect of different types of exercise supplementation on dipyridamole thallium image quality, 78 patients were prospectively randomized to one of three protocols: dipyridamole infusion alone, dipyridamole supplemented with isometric handgrip, and dipyridamole with low-level treadmill exercise. Heart-to-lung, heart-to-liver, and heart-to-adjacent infradiaphragmatic activity ratios were generated from anterior images acquired immediately following the test. Additionally, heart-to-total infradiaphragmatic activity was graded semiquantitatively. Results showed a significantly higher ratio of heart to subdiaphragmatic activity in the treadmill group as compared with dipyridamole alone (p less than 0.001) and dipyridamole supplemented with isometric handgrip exercise (p less than 0.001). No significant difference was observed between patients receiving the dipyridamole infusion, and dipyridamole supplemented with isometric handgrip exercise. The authors conclude that low-level treadmill exercise supplementation of dipyridamole infusion is an effective means of improving image quality. Supplementation with isometric handgrip does not improve image quality over dipyridamole alone

  14. Triple Detector SPECT Imaging with 99mTc-DMSA in Adult Patients with Urinary Tract Infection

    International Nuclear Information System (INIS)

    Ryu, Jin Sook; Bea, Woon Gyu; Moon, Dae Hyuk; Lee, Myung Hae; Kim, Soon Bae; Park, Su Kil; Park, Jung Sik; Hong, Chang Gi; Cho, Kyung Sik

    1992-01-01

    Although early diagnosis of urinary tract infection is important, the radiologic evaluation is still controversial because of the low sensitivity and the lack of cost-effectiveness. This study was carried out to evaluate the clinical utility of high resolution triple head 99m Tc-DMSA SPECT imaging in urinary tract infection. We prospectively performed 99m Tc-DMSA planar and SPECT imaging, ultrasound of kidney (US), intravenous pyelography (IVP) and voiding cystourethrography (VCU) in all 60 adult patients with UTI [26 with first episode of acute pyelonephritis (APN), 22 with recurrent APN, and 12 persistent asymptomatic pyuria] and 25 normal persons. To assess reversibility of the renal cortical defect (RCD), 99m Tc-DMSA SPECT was repeated 1 to 8 months later in those patients with abnormal initial findings. Overall detection rate of 99m Tc-DMSA SPECT imaging was 83% (50/60), but planar, US, IVP and VCU showed abnormal findings in 68%, 28%, 32% and 13%, respectively. 25 out of 27 patients with normal or single RCD were all normal in other radiological studies. Only two patients showed vesicoureteral reflux (VUR) on VCU (grade I) and mild hydronephrosis on IVP. But, high proportion of those with multiple RCD showed abnormal findings on US (17/33), IVP (18/33), and VCU (7/33): 67% in any of these 3 studies. Especially, 3 out 7 patients with VUR showed multiple RCD on 99m Tc-DMSA SPECT without any abnormality on IVP or US. 25 normal persons showed normal findings in all studies except one false positive finding on 99m Tc-DMSA SPECT imaging. Follow-up 99m Tc-DMSA SPECT was done in 28 patients (13 with single RCD, 15 with multiple RCD). All 13 patients with single RCD showed improvement. Those with multiple RCD presented improvement in 4, no change in 10, and aggravation in 1 on follow-up studies. With these results, we conclude: 1) 99m Tc-DMSA SPECT imaging is superior to planar imaging, US, IVP or VCU in detection of renal lesion in urinary tract infection. 99m Tc

  15. [Segmentation of whole body bone SPECT image based on BP neural network].

    Science.gov (United States)

    Zhu, Chunmei; Tian, Lianfang; Chen, Ping; He, Yuanlie; Wang, Lifei; Ye, Guangchun; Mao, Zongyuan

    2007-10-01

    In this paper, BP neural network is used to segment whole body bone SPECT image so that the lesion area can be recognized automatically. For the uncertain characteristics of SPECT images, it is hard to achieve good segmentation result if only the BP neural network is employed. Therefore, the segmentation process is divided into three steps: first, the optimal gray threshold segmentation method is employed for preprocessing, then BP neural network is used to roughly identify the lesions, and finally template match method and symmetry-removing program are adopted to delete the wrongly recognized areas.

  16. Physiological imaging with PET and SPECT in Dementia

    Energy Technology Data Exchange (ETDEWEB)

    Jagust, W.J. (California Univ., San Francisco, CA (United States). Dept. of Neurology Lawrence Berkeley Lab., CA (United States))

    1989-10-01

    Dementia is a medical problem of increasingly obvious importance. The most common cause of dementia, Alzheimer's disease (AD) accounts for at least 50% of all cases of dementia, with multi-infarct dementia the next most common cause of the syndrome. While the accuracy of diagnosis of AD may range from 80 to 90%, there is currently no laboratory test to confirm the diagnosis. Functional imaging techniques such as positron emission tomography (PET) and single photon emission computed tomography (SPECT) offer diagnostic advantages since brain function is unequivocally disturbed in all dementing illnesses. Both PET and SPECT have been utilized in the study of dementia. While both techniques rely on principles of emission tomography to produce three dimensional maps of injected radiotracers, the differences between positron and single photon emission have important consequences for the practical applications of the two procedures. This briefly reviews the technical differences between PET and SPECT, and discusses how both techniques have been used in our laboratory to elucidate the pathophysiology of dementia. 32 refs., 2 figs.

  17. Physiological imaging with PET and SPECT in Dementia

    International Nuclear Information System (INIS)

    Jagust, W.J.

    1989-10-01

    Dementia is a medical problem of increasingly obvious importance. The most common cause of dementia, Alzheimer's disease (AD) accounts for at least 50% of all cases of dementia, with multi-infarct dementia the next most common cause of the syndrome. While the accuracy of diagnosis of AD may range from 80 to 90%, there is currently no laboratory test to confirm the diagnosis. Functional imaging techniques such as positron emission tomography (PET) and single photon emission computed tomography (SPECT) offer diagnostic advantages since brain function is unequivocally disturbed in all dementing illnesses. Both PET and SPECT have been utilized in the study of dementia. While both techniques rely on principles of emission tomography to produce three dimensional maps of injected radiotracers, the differences between positron and single photon emission have important consequences for the practical applications of the two procedures. This briefly reviews the technical differences between PET and SPECT, and discusses how both techniques have been used in our laboratory to elucidate the pathophysiology of dementia. 32 refs., 2 figs

  18. Assessment of anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema with breath-hold SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Iwanaga, Hideyuki; Hayashi, Noriko; Seto, Akiko; Matsunaga, Naofumi

    2008-01-01

    Anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema was assessed on deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images. Subjects were 38 patients with pulmonary emphysema and 11 non-smoker controls, who successfully underwent DIBrH and non-BrH perfusion SPECT using a dual-headed SPECT system during the period between January 2004 and June 2006. DIBrH SPECT was three-dimensionally co-registered with DIBrH CT to comprehend the relationship between lung perfusion defects and CT low attenuation areas (LAA). By comparing the appearance of lung perfusion on DIBrH with non-BrH SPECT, the correlation with the rate constant for the alveolar-capillary transfer of carbon monoxide (DLCO/VA) was compared between perfusion abnormalities on these SPECTs and LAA on CT. DIBrH SPECT provided fairly uniform perfusion in controls, but significantly enhanced perfusion heterogeneity when compared with non-BrH SPECT in pulmonary emphysema patients (P<0.001). The reliable DIBrH SPECT-CT fusion images confirmed more extended perfusion defects than LAA on CT in majority (73%) of patients. Perfusion abnormalities on DIBrH SPECT were more closely correlated with DLCO/VA than LAA on CT (P<0.05). DIBrH SPECT identifies affected lungs with perfusion abnormality better than does non-BrH SPECT in pulmonary emphysema. DIBrH SPECT-CT fusion images are useful for more accurately localizing affected lungs than morphologic CT alone in this disease. (author)

  19. A novel computer-assisted image analysis of [123I]β-CIT SPECT images improves the diagnostic accuracy of parkinsonian disorders

    International Nuclear Information System (INIS)

    Goebel, Georg; Seppi, Klaus; Wenning, Gregor K.; Poewe, Werner; Scherfler, Christoph; Donnemiller, Eveline; Warwitz, Boris; Virgolini, Irene

    2011-01-01

    The purpose of this study was to develop an observer-independent algorithm for the correct classification of dopamine transporter SPECT images as Parkinson's disease (PD), multiple system atrophy parkinson variant (MSA-P), progressive supranuclear palsy (PSP) or normal. A total of 60 subjects with clinically probable PD (n = 15), MSA-P (n = 15) and PSP (n = 15), and 15 age-matched healthy volunteers, were studied with the dopamine transporter ligand [ 123 I]β-CIT. Parametric images of the specific-to-nondisplaceable equilibrium partition coefficient (BP ND ) were generated. Following a voxel-wise ANOVA, cut-off values were calculated from the voxel values of the resulting six post-hoc t-test maps. The percentages of the volume of an individual BP ND image remaining below and above the cut-off values were determined. The higher percentage of image volume from all six cut-off matrices was used to classify an individual's image. For validation, the algorithm was compared to a conventional region of interest analysis. The predictive diagnostic accuracy of the algorithm in the correct assignment of a [ 123 I]β-CIT SPECT image was 83.3% and increased to 93.3% on merging the MSA-P and PSP groups. In contrast the multinomial logistic regression of mean region of interest values of the caudate, putamen and midbrain revealed a diagnostic accuracy of 71.7%. In contrast to a rater-driven approach, this novel method was superior in classifying [ 123 I]β-CIT-SPECT images as one of four diagnostic entities. In combination with the investigator-driven visual assessment of SPECT images, this clinical decision support tool would help to improve the diagnostic yield of [ 123 I]β-CIT SPECT in patients presenting with parkinsonism at their initial visit. (orig.)

  20. A novel computer-assisted image analysis of [123I]β-CIT SPECT images improves the diagnostic accuracy of parkinsonian disorders.

    Science.gov (United States)

    Goebel, Georg; Seppi, Klaus; Donnemiller, Eveline; Warwitz, Boris; Wenning, Gregor K; Virgolini, Irene; Poewe, Werner; Scherfler, Christoph

    2011-04-01

    The purpose of this study was to develop an observer-independent algorithm for the correct classification of dopamine transporter SPECT images as Parkinson's disease (PD), multiple system atrophy parkinson variant (MSA-P), progressive supranuclear palsy (PSP) or normal. A total of 60 subjects with clinically probable PD (n = 15), MSA-P (n = 15) and PSP (n = 15), and 15 age-matched healthy volunteers, were studied with the dopamine transporter ligand [(123)I]β-CIT. Parametric images of the specific-to-nondisplaceable equilibrium partition coefficient (BP(ND)) were generated. Following a voxel-wise ANOVA, cut-off values were calculated from the voxel values of the resulting six post-hoc t-test maps. The percentages of the volume of an individual BP(ND) image remaining below and above the cut-off values were determined. The higher percentage of image volume from all six cut-off matrices was used to classify an individual's image. For validation, the algorithm was compared to a conventional region of interest analysis. The predictive diagnostic accuracy of the algorithm in the correct assignment of a [(123)I]β-CIT SPECT image was 83.3% and increased to 93.3% on merging the MSA-P and PSP groups. In contrast the multinomial logistic regression of mean region of interest values of the caudate, putamen and midbrain revealed a diagnostic accuracy of 71.7%. In contrast to a rater-driven approach, this novel method was superior in classifying [(123)I]β-CIT-SPECT images as one of four diagnostic entities. In combination with the investigator-driven visual assessment of SPECT images, this clinical decision support tool would help to improve the diagnostic yield of [(123)I]β-CIT SPECT in patients presenting with parkinsonism at their initial visit.

  1. Clinical application of SPECT in adrenal imaging with iodine-131 6 beta-iodomethyl-19-norcholesterol

    Energy Technology Data Exchange (ETDEWEB)

    Ishimura, J.; Kawanaka, M.; Fukuchi, M.

    1989-04-01

    Forty-one patients with or without adrenocortical disorders were studied to evaluate the clinical usefulness of SPECT in adrenal imaging with I-131 Adosterol. In the SPECT images from this study, all glands with either normally functioning or hyperfunctioning adrenal cortices could be detected, while those glands with hypofunctioning adrenal cortices could not be detected. Particularly in transaxial and sagittal slices, the adrenal gland was identified posteriorly and was clearly distinguished from the gallbladder. In preliminary results using SPECT by a standard method, uptake in 68 detectable glands ranged from 1.7% to 4.9% in four glands with Cushing's syndrome, from 1.1% to 1.3% in seven glands with primary aldosteronism, and were distributed below 1.0% in the remaining glands with normally functioning adrenal cortices. These data show that it is possible to evaluate the adrenocortical functioning status simply by analyzing the SPECT images of the adrenal.

  2. Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study

    Directory of Open Access Journals (Sweden)

    Banari Bahnamiri Sh

    2015-03-01

    Full Text Available Background: Obtaining high quality images in Single Photon Emission Tomography (SPECT device is the most important goal in nuclear medicine. Because if image quality is low, the possibility of making a mistake in diagnosing and treating the patient will rise. Studying effective factors in spatial resolution of imaging systems is thus deemed to be vital. One of the most important factors in SPECT imaging in nuclear medicine is the use of an appropriate collimator for a certain radiopharmaceutical feature in order to create the best image as it can be effective in the quantity of Full Width at Half Maximum (FWHM which is the main parameter in spatial resolution. Method: In this research, the simulation of the detector and collimator of SPECT imaging device, Model HD3 made by Philips Co. and the investigation of important factors on the collimator were carried out using MCNP-4c code. Results: The results of the experimental measurments and simulation calculations revealed a relative difference of less than 5% leading to the confirmation of the accuracy of conducted simulation MCNP code calculation. Conclusion: This is the first essential step in the design and modelling of new collimators used for creating high quality images in nuclear medicine

  3. Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Caobelli, Federico; Thackeray, James T.; Bengel, Frank M. [Medizinische Hochschule Hannover, Klinik fuer Nuklearmedizin, Hannover (Germany); Soffientini, Alberto; Pizzocaro, Claudio; Guerra, Ugo Paolo [Fondazione Poliambulanza, Department of Nuclear Medicine, Brescia (Italy)

    2015-11-15

    IQ-SPECT, an add-on to general purpose cameras based on multifocal collimation, can reduce myocardial perfusion imaging (MPI) acquisition times to one-fourth that of standard procedures (to 12 s/view). In a phantom study, a reduction of the acquisition time to one-eighth of the standard time (to 6 s/view) was demonstrated as feasible. It remains unclear whether such a reduction could be extended to clinical practice. Fifty patients with suspected or diagnosed CAD underwent a 2-day stress-rest {sup 99m}Tc-sestamibi MPI protocol. Two consecutive SPECT acquisitions (6 and 12 s/view) were performed. Electrocardiogram-gated images were reconstructed with and without attenuation correction (AC). Polar maps were generated and visually scored by two blinded observers for image quality and perfusion in 17 segments. Global and regional summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) were determined. Left ventricular volumes and ejection fraction were calculated based on automated contour detection. Image quality was scored higher with the 12 s/view acquisition, both with and without AC. Summed scores were statistically comparable between the 6 s/view and the 12 s/view acquisition, both globally and in individual coronary territories (e.g. in images with AC, SSS were 6.6 ± 8.3 and 6.2 ± 8.2 with 6 s and 12 s/view, respectively, p = 0.10; SRS were 3.9 ± 5.6 and 3.5 ± 5.3, respectively, p = 0.19; and SDS were 2.8 ± 5.7 and 2.6 ± 5.7, respectively, p = 0.59). Both acquisitions allowed MPI-based diagnosis of CAD in 25 of the 50 patients (with AC). Calculated end-diastolic volume (EDV) and end-systolic volume (ESV) were modestly higher with the 6 s/view acquisition than with the 12 s/view acquisition (EDV +4.8 ml at rest and +3.7 ml after stress, p = 0.003; ESV +4.1 ml at rest and +2.6 ml after stress, p = 0.01), whereas the ejection fraction did not differ (-1.2 % at rest, p = 0.20, and -0.9 % after stress, p = 0.27). Image quality and

  4. Towards adapting a normal patient database for SPECT brain perfusion imaging

    International Nuclear Information System (INIS)

    Smith, N D; Soleimani, M; Mitchell, C N; Holmes, R B; Evans, M J; Cade, S C

    2012-01-01

    Single-photon emission computerized tomography (SPECT) is a tool which can be used to image perfusion in the brain. Clinicians can use such images to help diagnose dementias such as Alzheimer's disease. Due to the intrinsic stochasticity in the photon imaging system, some form of statistical comparison of an individual image with a 'normal' patient database gives a clinician additional confidence in interpreting the image. Due to the variations between SPECT camera systems, ideally a normal patient database is required for each individual system. However, cost or ethical considerations often prohibit the collection of such a database for each new camera system. Some method of adapting existing normal patient databases to new camera systems would be beneficial. This paper introduces a method which may be regarded as a 'first-pass' attempt based on 2-norm regularization and a codebook of discrete spatially stationary convolutional kernels. Some preliminary illustrative results are presented, together with discussion on limitations and possible improvements

  5. Simultaneous low level treadmill exercise and intravenous dipyridamole stress thallium imaging

    International Nuclear Information System (INIS)

    Casale, P.N.; Guiney, T.E.; Strauss, H.W.; Boucher, C.A.

    1988-01-01

    Intravenous dipyridamole-thallium imaging unmasks ischemia in patients unable to exercise adequately. However, some of these patients can perform limited exercise, which, if added, may provide useful information. Treadmill exercise combined with dipyridamole-thallium imaging was performed in 100 patients and results compared with those of 100 other blindly age- and sex-matched patients who received dipyridamole alone. Exercise began after completion of the dipyridamole infusion. Mean +/- 1 standard deviation peak heart rate (109 +/- 19 vs 83 +/- 12 beats/min, p less than 0.0001) and peak systolic and diastolic blood pressure (146 +/- 28/77 +/- 14 vs 125 +/- 24/68 +/- 11 mm Hg, p less than 0.0001) were higher in the exercise group compared with the nonexercise group. There was no difference in the occurrence of chest pain, but more patients in the exercise group developed ST-segment depression (26 vs 12%, p less than 0.0001). The exercise group had fewer noncardiac side effects (4 vs 12%, p less than 0.01) and a higher target (heart) to background (liver) count ratio (2.1 +/- 0.7 vs 1.2 +/- 0.3; p less than 0.01), due to fewer liver counts. There were no deaths, myocardial infarctions or sustained arrhythmias in either group. Combined treadmill exercise and dipyridamole testing is safe, associated with fewer noncardiac side effects, a higher target to background ratio and a higher incidence of clinical electrocardiographic ischemia than dipyridamole alone. Therefore, it is recommended whenever possible

  6. Initial experience with SPECT imaging of the brain using I-123 p-iodoamphetamine in focal epilepsy

    International Nuclear Information System (INIS)

    La Manna, M.M.; Sussman, N.M.; Harner, R.N.; Kaplan, L.R.; Hershey, B.L.; Bernstein, D.R.; Parker, J.A.; Wolodzko, J.G.; Popky, G.L.

    1986-01-01

    Twenty-three patients with complex partial seizures refractory to medical treatment were examined with routine electroencephalography (EEG), closed-circuit television EEG (CCTV-EEG), CT and MR imaging, neuropsychological tests, and interictal single photon emission CT with I-123 rho-iodoamphetamine (IMP SPECT). In three patients CT and MR imaging results correlated with the epileptogenic foci as identified on CCTV-EEG. In 21 patients SPECT identified areas of focal reduction in tracer uptake that correlated with the epileptogenic focus identified on CCTV-EEG. In addition, SPECT disclosed other areas of neurologic dysfunction as elicited on neuropsychological tests. Thus, IMP SPECT is a useful tool for localizing epileptogenic foci and their associated dynamic deficits

  7. Clinical results with beta-methyl-p-(123I)iodophenylpentadecanoic acid, single-photon emission computed tomography in cardiac disease.

    Science.gov (United States)

    Nishimura, T; Uehara, T; Shimonagata, T; Nagata, S; Haze, K

    1994-01-01

    This study was undertaken to evaluate the relationships, between myocardial perfusion and metabolism. Simultaneous beta-methyl-p(123I)iodophenylpentadecanoic acid (123I-BMIPP) and thallium 201 myocardial single-photon emission computed tomography (SPECT) were performed in 25 patients with myocardial infarction (group A) and 16 patients with hypertrophic cardiomyopathy (group B). The severity scores of 123I-BMIPP and 201Tl myocardial SPECT images were evaluated semiquantitatively by segmental analysis. In Group A, dissociations between thallium- and 123I-BMIPP-imaged defects were frequently observed in patients with successful reperfusion compared with those with no reperfusion and those with reinfarction. In four patients with successful reperfusion, repeated 123I-BMIPP and 201Tl myocardial SPECT showed gradual improvement of the 123I-BMIPP severity score compared with the thallium severity score. In group B, dissociations between thallium- and 123I-BMIPP-imaged defects were also demonstrated in hypertrophic myocardium. In addition, nonhypertrophic myocardium also had decreased 123I-BMIPP uptake. In groups A and B, 123I-BMIPP severity scores correlated well with left ventricular function compared with thallium severity scores. These findings indicate that 123I-BMIPP is a suitable agent for the assessment of functional integrity, because left ventricular wall motion is energy dependent and 123I-BMIPP may reflect an aspect of myocardial energy production. This agent may be useful for the early detection and patient management of various heart diseases as an alternative to positron emission tomographic study.

  8. Automatic lung segmentation in functional SPECT images using active shape models trained on reference lung shapes from CT.

    Science.gov (United States)

    Cheimariotis, Grigorios-Aris; Al-Mashat, Mariam; Haris, Kostas; Aletras, Anthony H; Jögi, Jonas; Bajc, Marika; Maglaveras, Nicolaos; Heiberg, Einar

    2018-02-01

    Image segmentation is an essential step in quantifying the extent of reduced or absent lung function. The aim of this study is to develop and validate a new tool for automatic segmentation of lungs in ventilation and perfusion SPECT images and compare automatic and manual SPECT lung segmentations with reference computed tomography (CT) volumes. A total of 77 subjects (69 patients with obstructive lung disease, and 8 subjects without apparent perfusion of ventilation loss) performed low-dose CT followed by ventilation/perfusion (V/P) SPECT examination in a hybrid gamma camera system. In the training phase, lung shapes from the 57 anatomical low-dose CT images were used to construct two active shape models (right lung and left lung) which were then used for image segmentation. The algorithm was validated in 20 patients, comparing its results to reference delineation of corresponding CT images, and by comparing automatic segmentation to manual delineations in SPECT images. The Dice coefficient between automatic SPECT delineations and manual SPECT delineations were 0.83 ± 0.04% for the right and 0.82 ± 0.05% for the left lung. There was statistically significant difference between reference volumes from CT and automatic delineations for the right (R = 0.53, p = 0.02) and left lung (R = 0.69, p automatic quantification of wide range of measurements.

  9. A SPECT study in internal carotid artery occlusion: Discrepancies between flow image and neurologic deficits

    International Nuclear Information System (INIS)

    Moriwaki, H.; Hougaku, H.; Matsuda, I.; Kusunoki, M.; Shirai, J.

    1989-01-01

    A SPECT (single photon emission computed tomography) study in internal carotid artery (ICA) occlusion was performed in 6 patients. The validity of iodoamphetamine (IMP) SPECT study in the evaluation of cerebral blood flow (CBF) or neurologic function is still controversial. In this study, the authors showed several cases in whom SPECT images of brain were not compatible with their neurologic deficits. In 2 typical cases, a large low-density area was observed in the non-dominant hemisphere in computed tomography (CT) scan, but no apparent motor-sensory deficits in left limbs were present. In these patients, SPECT study also revealed flow reduction in the affected side of the brain. So there was a possibility that an IMP brain image could not always reflect CBF, which maintains neurologic function of the brain

  10. SPECT Imaging as a Tool for Testing and Challenging Assumptions About Transport in Porous Media

    Science.gov (United States)

    Moysey, S. M.; DeVol, T. A.; Tornai, M. P.

    2014-12-01

    Medical imaging has shown promise for unraveling the influence of physical, chemical and biological processes on contaminant transport. Micro-CT scans, for instance, are increasingly utilized to image the pore-scale structure of rocks and soils, which can subsequently be used within modeling studies. A disadvantage of micro-CT, however, is that this imaging modality does not directly detect contaminants. In contrast, Single Photon Emission Computed Tomography (SPECT) can provide the three-dimensional distribution of gamma emitting materials and is thus ideal for imaging the transport of radionuclides. SPECT is of particular interest as a tool for both directly imaging the behavior of long-lived radionuclides of interest, e.g., 99Tc and 137Cs, as well as monitoring shorter-lived isotopes as in-situ tracers of flow and biogeochemical processes. We demonstrate the potential of combining CT and SPECT imaging to improve the mechanistic understanding of flow and transport processes within a heterogeneous porous medium. In the experiment, a column was packed with 0.2mm glass beads with a cylindrical zone of 2mm glass beads embedded near the outlet; this region could be readily identified within the CT images. The column was injected with a pulse of NaCl solution spiked with 99mTcO4- and monitored using SPECT while aliquots of the effluent were used to analyze the breakthrough of both solutes. The breakthrough curves could be approximately replicated by a one-dimensional transport model, but the SPECT data revealed that the tracers migrated around the inclusion of larger beads. Although the zone of large-diameter beads was expected to act as a preferential pathway, the observed behavior could only be replicated in numerical transport simulations if this region was treated as a low-permeability zone relative to the rest of the column. This simple experiment demonstrates the potential of SPECT for investigating flow and transport phenomena within a porous medium.

  11. Myocardial imaging with thallium-201: an experimental model for analysis of the true myocardial and background image components

    International Nuclear Information System (INIS)

    Narahara, K.A.; Hamilton, G.W.; Williams, D.L.; Gould, K.L.

    1977-01-01

    The true myocardial and background components of a resting thallium-201 myocardial image were determined in an experimental dog model. True background was determined by imaging after the heart had been removed and replaced with a water-filled balloon of equal size and shape. In all studies, the background estimated from the region surrounding the heart exceeded true background activity. Furthermore, the relationship between true myocardial background and that estimated from the pericardiac region was inconsistent. Background estimates based on the activity surrounding the heart were not accurate predictors of true background activity

  12. Intravenous dipyridamole thallium-201 SPECT imaging methodology, applications, and interpretations

    International Nuclear Information System (INIS)

    Rockett, J.F.; Magill, H.L.; Loveless, V.S.; Murray, G.L.

    1990-01-01

    Dipyridamole TI-201 imaging is an ideal alternative to exercise TI-201 scintigraphy in patients who are unwilling or unable to perform maximum exercise stress. The use of intravenous dipyridamole, alone or in combination with exercise, has not been approved for clinical practice by the Food and Drug Administration. Once approval is granted, the test will become a widely used and important component of the cardiac work-up. The indications, methodology, side effects, and utility of dipyridamole cardiac imaging in the clinical setting are discussed and a variety of examples presented.59 references

  13. Tardily accelerated neurologic deterioration in two-step thallium intoxication.

    Science.gov (United States)

    Kuroda, Hiroshi; Mukai, Yoshiyuki; Nishiyama, Shuhei; Takeshita, Takayuki; Tateyama, Maki; Takeda, Atsushi; Aoki, Masashi

    2016-12-01

    Thallium intoxication was reported in cases with accidental ingestion, suicide attempt, and criminal adulteration. Reported cases were mostly one-time ingestion, therefore, the clinical course of divisional ingestion has not been fully known. Here, we report a case with two-step thallium intoxication manifesting as tardily accelerated neurologic deterioration. A 16-year-old adolescent was cryptically poisoned with thallium sulfate twice at an interval of 52days. After the first ingestion, neurologic symptoms including visual loss, myalgia, and weakness in legs developed about 40days after the development of acute gastrointestinal symptoms and alopecia. After the second ingestion, neurologic symptoms deteriorated rapidly and severely without gastrointestinal or cutaneous symptoms. Brain magnetic resonance imaging exhibited bilateral optic nerve atrophy. Nerve conduction studies revealed severe peripheral neuropathies in legs. Thallium intoxication was confirmed by an increase in urine thallium egestion. Most of the neurologic manifestations ameliorated in two years, but the visual loss persisted. The source of thallium ingestion was unraveled afterward because a murder suspect in another homicidal assault confessed the forepast adulteration. This discriminating clinical course may be attributable to the cumulative neurotoxicity due to the longer washout-time of thallium in the nervous system than other organs. It is noteworthy that the divisional thallium intoxication may manifest as progressive optic and peripheral neuropathy without gastrointestinal or cutaneous symptoms. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Assessment of vascularization within hydroxyapatite ocular implant by bone scintigraphy: compartive analysis of planar and SPECT imaging

    International Nuclear Information System (INIS)

    Lim, Seok Tae; Sohn, Myung Hee; Park, Soon Ah

    1999-01-01

    Complete fibrovascular ingrowth within the hydroxyapatite ocular implant is necessary for peg drilling which is performed to prevent infection and to provide motility to the ocular prosthesis. We compared planar bone scintigraphy and SPECT for the evaluation of the vascularization within hydroxyapatite ocular implants. Seventeen patients (M:F=12:5, mean age: 50.4±17.5 years) who had received a coralline hydroxyapatite ocular implant after enucleation surgery were enrolled. Patients underwent Tc-99m MDP planar bone and SPECT imaging by dual head gamma camera after their implant surgery (interval: 197±81 days). Uptake on planar and SPECT images was graded visually as less than (grade 1), equal to (grade 2), and greater than (grade 3) nasal bridge activity. Quantitative ratio of implanted to non-implanted intraorbital activity was also measured. Vascularization within hydroxyapatite implants was confirmed by slit lamp examination and ocular movement. All but three patients were considered to be vascularized within hydroxyapatite implants. In visual analysis of planar image and SPECT, grade 1 was noted in 9/18 (50%) and 6/18 (33%), respectively. Grade 2 pattern 7/18 (39%) and 4/18 (22%), and grade 3 pattern was 2/18 (11%) and 8/18 (44%) respectively. When grade 2 or 3 was considered to be positive for vascularization, the sensitivity of planar and SPECT imaging were 60% (9/15) and 80% (12/15), respectively. In 3 patients with incomplete vascularization, both planar and SPECT showed grade 1 uptake. The orbital activity ratios on planar imaging were not significantly different between complete and incomplete vascularization (1.96±9.87 vs 1.17±0.08 , p>0.05), however, it was significantly higher on SPECT in patients with complete vascularization (8.44±5.45 vs 2.20±0.87, p<0.05). In the assessment of fibrovascular ingrowth within ocular implants by Tc-99m MDP bone scintigraphy, SPECT image appears to be more effective than planar scintigraphy

  15. Study on localization diagnosis with SPECT rCBF image in childhood epilepsy: in comparison with EEG and MRI findings

    International Nuclear Information System (INIS)

    Wu Meiqian; Tang Jihong; Wu Jinchang; Shi Yizhen

    1999-01-01

    Objective: To evaluate the diagnostic value of SPECT rCBF imaging in localization of childhood epileptic foci. Methods: rCBF imaging was performed in 74 epileptic patients not in seizure and 10 epileptic patients right in seizure. EEG was performed in 84, MRI in 67 of the subjects mentioned above. All the results of three modalities were compared with each other. Results: The highest positive rate (82.14%) was found in SPECT rCBF imaging, the positive rate in EEG or MRI was 71.43 or 47.76%. The epileptic foci localized by EEG (60 abnormalities) and by MRI (32 abnormalities) were 70.59% or 58.82% in concordance with those by SPECT, respectively. Conclusions: SPECT rCBF imaging is a sensitive and effective method for epileptic foci localization. It may have some advantages over EEG and MRI in detecting and localizing epileptic foci. However, abnormal SPECT areas may cover some abnormalities which do not belong to epileptic category. A combination of these three methods (SPECT, EEG and MRI) will improve the positive rate and accuracy for localizing

  16. Risk stratification of patients with hypertension using exercise thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Kane, S.

    1985-01-01

    Hypertension (HT) is an important risk factor in coronary heart disease (CHD) and cardiac morbidity and mortality. This study examined the value of clinical, ECG, exercise (EX) and thallium-201 imaging descriptors that identify patients (pts) with HT at high risk. The 337 pts in the study underwent EX thallium-201 testing for evaluation of chest pain due to suspected or proven CHD. The mean age was 55 years, of whom 79% were still on active anti-HT therapy at the time of the study. The EX thallium scintigrams were evaluated qualitatively and quantitively using circumferential profile analysis. The scans were abnormal in 162 pts (48%) and reversible perfusion defects were present in 106 of the 162 pts (65%). At a folllowup fo up to 74 months, (15 +- 9 mean +- SD), 11 pts had hard cardiac events: 2 died of cardiac causes and 9 had non-fatal acute myocardial infractions. There were no significant differences between those with and without events in age, EX heart rate and double product, EX duration, blood pressure and EX ECG changes. Univariate and multivariate survival analysis (Cox regression model) of important clinical, ECG, EX and thallium variables, identified the presence of abnormal EX images as the only predictor of outcome. (X/sup 2/ = 5.4, p< 0.02). No other variable provided additional prognostic information. Actuarial life table analysis showed that pts with abnormal images had significantly more events than those with normal images (p = 0.008, Mantel-Cox). Thus, EX thallium imaging is useful in risk stratification in pts with HT. The presence of abnormal images identify a subgroup at high risk for future events

  17. Thallium-201 accumulation in cerebral candidiasis: Unexpected finding on SPECT

    International Nuclear Information System (INIS)

    Tonami, N.; Matsuda, H.; Ooba, H.; Yokoyama, K.; Hisada, K.; Ikeda, K.; Yamashita, J.

    1990-01-01

    The authors present an unexpected finding of Tl-201 uptake in the intracerebral lesions due to candidiasis. SPECT demonstrated the extent of the lesions and a high target-to-background ratio. The regions where abnormal Tl-201 accumulation was seen were nearly consistent with CT scans of those enhanced by a contrast agent. After treatment, most of the abnormal Tl-201 accumulation disappeared

  18. Thallium-201 accumulation in cerebral candidiasis: Unexpected finding on SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tonami, N.; Matsuda, H.; Ooba, H.; Yokoyama, K.; Hisada, K.; Ikeda, K.; Yamashita, J. (Kanazawa Univ. (Japan))

    1990-06-01

    The authors present an unexpected finding of Tl-201 uptake in the intracerebral lesions due to candidiasis. SPECT demonstrated the extent of the lesions and a high target-to-background ratio. The regions where abnormal Tl-201 accumulation was seen were nearly consistent with CT scans of those enhanced by a contrast agent. After treatment, most of the abnormal Tl-201 accumulation disappeared.

  19. The parallel implementation of a backpropagation neural network and its applicability to SPECT image reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kerr, John Patrick [Iowa State Univ., Ames, IA (United States)

    1992-01-01

    The objective of this study was to determine the feasibility of using an Artificial Neural Network (ANN), in particular a backpropagation ANN, to improve the speed and quality of the reconstruction of three-dimensional SPECT (single photon emission computed tomography) images. In addition, since the processing elements (PE)s in each layer of an ANN are independent of each other, the speed and efficiency of the neural network architecture could be better optimized by implementing the ANN on a massively parallel computer. The specific goals of this research were: to implement a fully interconnected backpropagation neural network on a serial computer and a SIMD parallel computer, to identify any reduction in the time required to train these networks on the parallel machine versus the serial machine, to determine if these neural networks can learn to recognize SPECT data by training them on a section of an actual SPECT image, and to determine from the knowledge obtained in this research if full SPECT image reconstruction by an ANN implemented on a parallel computer is feasible both in time required to train the network, and in quality of the images reconstructed.

  20. Methods of thallium-201 preparation from proton irradiated thallium targets

    International Nuclear Information System (INIS)

    Kozlova, M.D.; Sevast'yanova, A.S.; Malinin, A.B.; Kurenkov, N.V.

    1989-01-01

    Two methods of thallium-201 preparation from Tl-targets irradiated by protons: oxidation-extraction (1) and extraction (2) - are developed. At first radioactive lead is separated from the target material - thallium macroquantities during ∼32 hours, then thallium-201 was separated from residual activity of lead radioisotopes and transformed it into the necessary chemical formula. The 1st and 2nd methods differ from each other by the 1st stage of target retreatment; only extraction was used to separate radioactive lead in the 2nd method. The target was solved in H 2 SO 4 . The 1st method permits to separate thallium-201 with chemical yield not less than 90 %, the 2nd one - higher than 95 %. Volumetric activity of thallium-201 prepared is more than 55 MBq/ml. 5 refs

  1. Mechanisms of thallium-201 accumulation to thyroid gland

    International Nuclear Information System (INIS)

    Kishida, Toshihiro

    1987-01-01

    In this study 91 patients with goiter were scintigraphed for the duration of 84 minutes after intravenous administration of thallium-201 by digital γ camera lined to computer data system. Regions of interest (ROIs) were assigned for thyroid tumor, normal thyroid and back ground, and time-activity curves (TACs) were generated from these ROIs. Na + , K + -ATPase activity of microsome fraction from thyroid tumor and the normal thyroid glands was determined. The first 15 minutes accumulation of each ROI was determined as the early accumulation of thallium-201 for tumor and the normal thyroid glands. Papillary and follicular carcinomas, showing the high accumulation of thallium-201, had high activity of Na + , K + -ATPase. Microfollicular adenomas had high activity of Na + , K + -ATPase and demonstrated intense accumulation of thallium-201. However, colloid adenoma had a similar level of Na + , K + -ATPase activity to that of the normal thyroid glands and did not demonstrate radionuclide accumulation. Consequently, radionuclide accumulation in thallium-201 thyroid scintigraphy was closely correlated to Na + , K + -ATPase activity of thyroid tumor. Thyroid blood flow was measured by hydrogen gas clearance method. Thyroid blood flow of papillary carcinoma was smaller, as compared with normal thyroid blood flow. TAC of papillary carcinoma showed flattening. Thallium-201 accumulation in early image was also found to correspond to thyroid blood flow. From this study we can conclude that mechanisms of thallium-201 accumulation in a thyroid tumor depends on Na + , K + -ATPase activity and thyroid blood flow. Washout of TAC in thallium-201 scintigraphy appears dependent on blood flow of a thyroid nodule. (author)

  2. A novel computer-assisted image analysis of [{sup 123}I]{beta}-CIT SPECT images improves the diagnostic accuracy of parkinsonian disorders

    Energy Technology Data Exchange (ETDEWEB)

    Goebel, Georg [Innsbruck Medical University, Department of Medical Statistics, Informatics and Health Economics, Innsbruck (Austria); Seppi, Klaus; Wenning, Gregor K.; Poewe, Werner; Scherfler, Christoph [Innsbruck Medical University, Department of Neurology, Innsbruck (Austria); Donnemiller, Eveline; Warwitz, Boris; Virgolini, Irene [Innsbruck Medical University, Department of Nuclear Medicine, Innsbruck (Austria)

    2011-04-15

    The purpose of this study was to develop an observer-independent algorithm for the correct classification of dopamine transporter SPECT images as Parkinson's disease (PD), multiple system atrophy parkinson variant (MSA-P), progressive supranuclear palsy (PSP) or normal. A total of 60 subjects with clinically probable PD (n = 15), MSA-P (n = 15) and PSP (n = 15), and 15 age-matched healthy volunteers, were studied with the dopamine transporter ligand [{sup 123}I]{beta}-CIT. Parametric images of the specific-to-nondisplaceable equilibrium partition coefficient (BP{sub ND}) were generated. Following a voxel-wise ANOVA, cut-off values were calculated from the voxel values of the resulting six post-hoc t-test maps. The percentages of the volume of an individual BP{sub ND} image remaining below and above the cut-off values were determined. The higher percentage of image volume from all six cut-off matrices was used to classify an individual's image. For validation, the algorithm was compared to a conventional region of interest analysis. The predictive diagnostic accuracy of the algorithm in the correct assignment of a [{sup 123}I]{beta}-CIT SPECT image was 83.3% and increased to 93.3% on merging the MSA-P and PSP groups. In contrast the multinomial logistic regression of mean region of interest values of the caudate, putamen and midbrain revealed a diagnostic accuracy of 71.7%. In contrast to a rater-driven approach, this novel method was superior in classifying [{sup 123}I]{beta}-CIT-SPECT images as one of four diagnostic entities. In combination with the investigator-driven visual assessment of SPECT images, this clinical decision support tool would help to improve the diagnostic yield of [{sup 123}I]{beta}-CIT SPECT in patients presenting with parkinsonism at their initial visit. (orig.)

  3. Reverse redistribution on planar thallium scintigraphy: relationship to resting thallium uptake and long-term outcome

    International Nuclear Information System (INIS)

    Dey, H.M.; Soufer, R.

    1995-01-01

    Reverse redistribution (RR) of thallium-201 has been associated with both acute and healed myocardial infarction, and with recent thrombolysis. The physiologic basis for RR in coronary artery disease (CAD) is unclear but may be related to an admixture of viable and scarred myocardium within the RR segment. We performed thallium reinjection imaging at rest to better characterize RR defects in patients with chronic CAD. We found enhanced uptake of 201 Tl in 52% of RR segments after reinjection, consistent with significant regional viability that was not evident on redistribution images. We then used a logistic multiple regression analysis to determine whether RR alone or in combination with other scintigraphic findings could predict patient outcome. The results showed that severe RR was an independent predictor of patient outcome. We conclude that RR may have prognostic significance in chronic CAD. (orig.)

  4. Utility of thallium-201 and iodine-123 metaiodobenzylguanidine in the scintigraphic detection of neuroendocrine neoplasia

    International Nuclear Information System (INIS)

    Montravers, F.; Coutris, G.; Sarda, L.; Mensch, B.; Talbot, J.N.

    1993-01-01

    In order to determine whether the association of the two markers is able to improve the detection of neuroendocrine lesions, 137 sctinigraphic examinations using MIBG and thallium were performed in 101 patients referred for suspicion or follow-up of neuroendocrine tumours. Thallium chloride was first injected (1 MBq/kg), images being acquired about 20 min after injection; 123 I-MIBG (4 MBq/kg) was then injected and images acquired 5 and 24 h later. In patients with phaeochromocytoma or neuroblastoma, thallium scintigraphy appeared of little help since no tumoural site was discovered by thallium accumulation alone. In contrast, thallium examination seemed of interest in the detection of paraganglioma and MTC, the association of the two radiopharmaceuticals increasing the number of detected sites. (orig./MTG)

  5. Kit formulated asialoglycoprotein receptor targeting tracer based on copolymer for liver SPECT imaging

    International Nuclear Information System (INIS)

    Liu, Chang; Guo, Zhide; Zhang, Pu; Song, Manli; Zhao, Zuoquan; Wu, Xiaowei; Zhang, Xianzhong

    2014-01-01

    Introduction: Specific targeting of galactose-carrying molecule to ASGP-R in normal hepatocytes has been demonstrated before. In this study, galactosyl polystyrene was synthesized from controllable ratio of functional monomers and radio-labelled with 99m Tc by formulated kit for SPECT imaging of hepatic function. Methods: p(VLA-co-VNI)(46:54) was synthesized by free-radical copolymerization initiated by AIBN, purified by dialysis, lyophilized to kit with Tricine and TPPTS as co-ligands for 99m Tc labeling. Radiotracer 99m Tc-p(VLA-co-VNI)(46:54)(Tricine)(TPPTS) was prepared and evaluated by in vitro stability, in vivo metabolism, ex vivo biodistribution and microSPECT/CT imaging in normal KM mice. MicroSPECT/CT and microMRI imaging were also performed in C57BL/b6 mice with xenograft hepatic carcinoma for hepatic function evaluation. Results: 99m Tc-p(VLA-co-VNI)(46:54)(Tricine)(TPPTS) was obtained in high radio chemical purity (RCP) (> 99%) by using instant kit without further purification and excellent in vitro and in vivo stability. The result of biodistribution showed that liver had high uptake (90.49 ± 10.68 ID%/g) at 30 min after injection and was blocked significantly by cold copolymer. MicroSPECT imaging in normal KM mice at 1 h and 4 h after injection showed good liver retention and targeting properties. Significant defect of activity was observed in the tumor site which was confirmed by MRI imaging. Conclusion: 99m Tc-p(VLA-co-VNI)(46:54)(Tricine)(TPPTS) with lower ratio of targeting moiety has no observable effect on the specific binding affinity and liver uptake. This makes it possible to introduce more imaging units for multi-modality imaging. Furthermore, the instant kit preparation of 99m Tc-labeling provides great potential for the evaluation of hepatocyte function in clinical application

  6. Comparison of rest and exercise thallium-201 kinetics in man and implications for quantitation

    International Nuclear Information System (INIS)

    Freeman, M.R.; Kanwar, N.; Armstrong, P.W.

    1989-01-01

    To develop a technique for quantitative analysis of resting thallium scintigrams, an understanding of thallium kinetics at rest is required. This study evaluates in normal man the thallium distribution and washout rates of thallium at rest and compares these findings to similar data obtained during exercise. The thallium half-life in normal resting myocardium is significantly longer than after exercise, 10.2 +/- 1.4 hours versus 3.9 +/- 0.3 hours (P less than .01). Differences in resting thallium half-life exist between the anterior, 45 degrees left anterior oblique (LAO), and 70 degrees LAO views and are 11.4 +/- 1.0, 10.6 +/- 1.0, 8.8 +/- 0.7 hours, respectively (all significantly different from each other by ANOVA, P less than or equal to .01); these differences are related to the imaging sequence. After exercise, the thallium half-life also varies according to imaging sequence, but in the opposite direction; i.e., anterior, 45 degrees LAO, and 70 degrees LAO views are 3.6 +/- 0.1, 3.9 +/- 0.3, 4.2 +/- 0.3 hours, respectively (P less than or equal to .01). Since imaging sequence and time of acquisition at rest and exercise were similar, this finding may be related to earlier maximal uptake of thallium after exercise as compared to rest. There are also significant segmental differences in thallium half-life at rest in the 45 degrees LAO view (9.8 +/- 0.9, septal vs. 11.0 +/- 0.9, posterolateral, P less than .01) and 70 degrees LAO view (8.3 +/- 0.4, anteroseptal vs. 9.2 +/- 0.6, inferior, P less than or equal to .01)

  7. Brain SPECT. SPECT in der Gehirndiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Feistel, H. (Erlangen-Nuernberg Univ., Erlangen (Germany). Nuklearmedizinische Klinik mit Poliklinik)

    1991-12-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG).

  8. Vestibularis-schwannomers diagnostik og vaekst bedømt ved SPECT kombineret med TL-201 Thallium

    DEFF Research Database (Denmark)

    Charabi, S; Lassen, N A; Jacobsen, G K

    1999-01-01

    The value of SPECT scanning in diagnosis and growth potential of vestibular schwannoma (VS) was investigated in a series of 29 patients. SPECT demonstrated all tumours > 0.8 cm3, but had limitations as a diagnostic modality of small intracanalicular tumours, when compared to gadolinium DTPA...

  9. Technetium-99m-labelled red blood cell imaging in the diagnosis of hepatic haemangiomas: the role of SPECT/CT with a hybrid camera

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio; Danieli, Roberta; Manni, Carlo; Capoccetti, Francesca; Simonetti, Giovanni [Department of Biopathology and Diagnostic Imaging, University ' ' Tor Vergata' ' , Rome (Italy)

    2004-07-01

    Delayed liver single-photon emission computed tomography (SPECT) after {sup 99m}Tc red blood cell (RBC) labelling is helpful in detecting hepatic haemangiomas; however, diagnosis can be difficult when lesions are situated adjacent to structures like the inferior vena cava, the heart or hepatic vessels, where blood activity persists. The aims of this study were to evaluate the usefulness of RBC SPECT and transmission computed tomography (RBC SPECT/CT) performed simultaneously with a hybrid imaging system for correct characterisation of hepatic lesions in patients with suspected haemangioma, and to assess the additional value of fused images compared with SPECT alone. Twelve patients with 24 liver lesions were studied. The acquisitions of both anatomical (CT) and functional (SPECT) data were performed during a single session. SPECT images were first interpreted alone and then re-evaluated after adding the transmission anatomical maps. Image fusion was successful in all patients, with perfect correspondence between SPECT and CT data, allowing the precise anatomical localisation of sites of increased blood pool activity. SPECT/CT had a significant impact on results in four patients (33.3%) with four lesions defined as indeterminate on SPECT images, accurately characterising the hot spot foci located near vascular structures. In conclusion, RBC SPECT/CT imaging using this hybrid SPECT/CT system is feasible and useful in the identification or exclusion of suspected hepatic haemangiomas located near regions with high vascular activity. (orig.)

  10. Value of Tc-99m HMPAO SPECT imaging in patients with TIA or acute stroke and normal CT

    International Nuclear Information System (INIS)

    Koster, K.; Brass, L.M.; Hoffer, P.B.; Gottschalk, A.; Smith, E.O.; Rehm, P.K.

    1988-01-01

    To determine the value of Tc-99m HMPAO single photon emission CT (SPECT) imaging, 51 patients with transient, acute, or chronic cerebrovascular disease were studied. Seventeen patients presented with recent transient ischemic attack (TIA) or acute stroke and underwent SPECT imaging and CT within 72 hours of presentation. SPECT image interpretation was independent of clinical history and CT findings. Four patients with acute stroke and eight patients with TIA had normal CT findings. All patients with acute stroke (three nonlacunar, one lacunar infarct) and three of eight patients with TIA also showed perfusion abnormalities on Tc-99m HMPAO scans. Thus, Tc-99m HMPAO SPECT may be useful in the early diagnosis and subtype determination of acute stroke and in the evaluation of TIA

  11. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  12. Comparison of the distribution of some thallium chemical species in mice

    International Nuclear Information System (INIS)

    Petitjean, Francoise.

    Scintigraphic images obtained after injection of radioactive thallium show a strong uptake on the kidneys but also on the intestines, which means that quantitative interpretation of the kidney images is troubled by the superposition of these organs. This study is an attempt to find a chemical form of thallium tending less to fix on the intestinal mucous membrane but keeping its affinity for the medullary zone of the kidney. Various agents forming stable complexes with the metal were investigated. Radiothallium is generally used in the chemical form of monovalent thallium chloride. However the degree of oxidation I is unsuitable for stable complex formation and therefore trivalent thallium was also used. Separation of Tl(I) and Tl(III) with ion exchange resin showed the instability of trivalent chloride at low concentration and when the solution is more than 2 hours old the trivalent thallium solutions injected are 10 -5 M. Calculation of the complex formation constants revealed the absence or formation of monovalent thallium complexes. In all monovalent thallium solutions (with or without carrier, with EDTA or HEDTA) the predominant chemical species is Tl + . In the case of trivalent thallium three solutions with carrier were used; the predominant species is TlCl 6 3- when the solution contains Cl - and EDTA and TlEDTA when Cl - , NO 3 - and EDTA are present. These solutions were injected intraveinously into mice in order to study the radiothallium distribution in the kidney and intestine by comparison with that of TlCl while the chemical species varied from one preparation to another no great difference in the radiothallium distribution was observed [fr

  13. Molecular imaging of cancer using PET and SPECT

    DEFF Research Database (Denmark)

    Kjaer, Andreas

    2006-01-01

    for molecular imaging of cancer. Especially the possibility of a quick transfer of methods developed in animals to patients (translational research) is an important strength. This article will briefly discuss the newest applications and their importance and perspective in relation to the shift in paradigm......Molecular imaging allows for the study of molecular and cellular events in the living intact organism. The nuclear medicine methodologies of positron emission tomography (PET) and single photon emission computer tomography (SPECT) posses several advantages, which make them particularly suited...

  14. A Silicon SPECT System for Molecular Imaging of the Mouse Brain

    OpenAIRE

    Shokouhi, Sepideh; Fritz, Mark A.; McDonald, Benjamin S.; Durko, Heather L.; Furenlid, Lars R.; Wilson, Donald W.; Peterson, Todd E.

    2007-01-01

    We previously demonstrated the feasibility of using silicon double-sided strip detectors (DSSDs) for SPECT imaging of the activity distribution of iodine-125 using a 300-micrometer thick detector. Based on this experience, we now have developed fully customized silicon DSSDs and associated readout electronics with the intent of developing a multi-pinhole SPECT system. Each DSSD has a 60.4 mm × 60.4 mm active area and is 1 mm thick. The strip pitch is 59 micrometers, and the readout of the 102...

  15. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  16. Automated Analysis of 123I-beta-CIT SPECT Images with Statistical Probabilistic Anatomical Mapping

    International Nuclear Information System (INIS)

    Eo, Jae Seon; Lee, Hoyoung; Lee, Jae Sung; Kim, Yu Kyung; Jeon, Bumseok; Lee, Dong Soo

    2014-01-01

    Population-based statistical probabilistic anatomical maps have been used to generate probabilistic volumes of interest for analyzing perfusion and metabolic brain imaging. We investigated the feasibility of automated analysis for dopamine transporter images using this technique and evaluated striatal binding potentials in Parkinson's disease and Wilson's disease. We analyzed 2β-Carbomethoxy-3β-(4- 123 I-iodophenyl)tropane ( 123 I-beta-CIT) SPECT images acquired from 26 people with Parkinson's disease (M:F=11:15,mean age=49±12 years), 9 people with Wilson's disease (M: F=6:3, mean age=26±11 years) and 17 normal controls (M:F=5:12, mean age=39±16 years). A SPECT template was created using striatal statistical probabilistic map images. All images were spatially normalized onto the template, and probability-weighted regional counts in striatal structures were estimated. The binding potential was calculated using the ratio of specific and nonspecific binding activities at equilibrium. Voxel-based comparisons between groups were also performed using statistical parametric mapping. Qualitative assessment showed that spatial normalizations of the SPECT images were successful for all images. The striatal binding potentials of participants with Parkinson's disease and Wilson's disease were significantly lower than those of normal controls. Statistical parametric mapping analysis found statistically significant differences only in striatal regions in both disease groups compared to controls. We successfully evaluated the regional 123 I-beta-CIT distribution using the SPECT template and probabilistic map data automatically. This procedure allows an objective and quantitative comparison of the binding potential, which in this case showed a significantly decreased binding potential in the striata of patients with Parkinson's disease or Wilson's disease

  17. Collimator and energy window optimization for 90Y bremsstrahlung SPECT imaging: A SIMIND Monte Carlo study

    International Nuclear Information System (INIS)

    Roshan, Hoda Rezaei; Mahmoudian, Babak; Gharepapagh, Esmaeil; Azarm, Ahmadreza; Pirayesh Islamian, Jalil

    2016-01-01

    Treatment efficacy of radioembolization using Yttrium-90 ( 90 Y) microspheres is assessed by the 90 Y bremsstrahlung single photon emission computed tomography (SPECT) imaging following radioembolization. The radioisotopic image has the potential of providing reliable activity map of 90 Y microspheres distribution. One of the main reasons of the poor image quality in 90 Y bremsstrahlung SPECT imaging is the continuous and broad energy spectrum of the related bremsstrahlung photons. Furthermore, collimator geometry plays an impressive role in the spatial resolution, sensitivity and image contrast. Due to the relatively poor quality of the 90 Y bremsstrahlung SPECT images, we intend to optimize the medium-energy (ME) parallel-hole collimator and energy window. The Siemens e.cam gamma camera equipped with a ME collimator and a voxelized phantom was simulated by the SImulating Medical Imaging Nuclear Detectors (SIMIND) program. We used the SIMIND Monte Carlo program to generate the 90 Y bremsstrahlung SPECT projection of the digital Jaszczak phantom. The phantom consist of the six hot spheres ranging from 9.5 to 31.8 mm in diameter, which are used to evaluate the image contrast. In order to assess the effect of the energy window on the image contrast, three energy windows ranging from 60 to 160 KeV, 160 to 400 KeV, and 60 to 400 KeV were set on a 90 Y bremsstrahlung spectrum. As well, the effect of the hole diameter of a ME collimator on the image contrast and bremsstrahlung spectrum were investigated. For the fixed collimator and septa thickness values (3.28 cm and 1.14 mm, respectively), a hole diameter range (2.35–3.3 mm) was chosen based on the appropriate balance between the spatial resolution and sensitivity. The optimal energy window for 90 Y bremsstrahlung SPECT imaging was extended energy window from 60 to 400 KeV. Besides, The optimal value of the hole diameter of ME collimator was obtained 3.3 mm. Geometry of the ME parallel-hole collimator and energy

  18. Comparative methods for quantifying thyroid volume using planar imaging and SPECT

    International Nuclear Information System (INIS)

    Zaidi, H.

    1996-01-01

    Thyroid volume determination using planar imaging is a procedure often performed in routine nuclear medicine, but is hampered by several physical difficulties, in particular by structures which overlie or underlie the organ of interest. SPECT enables improved accuracy over planar imaging in the determination of the volume since it is derived from the 3-D data rather than from a 2-D projection with a certain geometric assumption regarding the thyroid configuration. By using the phantoms of known volume, it was possible to estimate the accuracy of 3 different methods of determining thyroid volume from planar imaging used in clinical routine. The experimental results demonstrate that compared with conventional scintigraphy, thyroid phantom volumes were most accurately determined with SPECT when attenuation and scatter corrections are performed which allows accurate radiation dosimetry in humans without the need for assumptions on organ size or concentrations. Poster 181. (author)

  19. SPECT/CT Fusion in the Diagnosis of Hyperparathyroidism

    International Nuclear Information System (INIS)

    Monzen, Yoshio; Tamura, Akihisa; Okazaki, Hajime; Kurose, Taichi; Kobayashi, Masayuki; Kuraoka, Masatsugu

    2015-01-01

    In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/ computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) were imaged 15 and 120 minutes after the intravenous injection of technetium99m-methoxyisobutylisonitrile ( 99m Tc-MIBI). All patients underwent surgery and 5 parathyroid adenomas and 10 hyperplastic glands were detected. Pathologic findings were correlated with imaging results. The SPECT/CT fusion images were able to detect all parathyroid adenomas even with the greatest axial diameter of 0.6 cm. Planar scintigraphy and SPECT imaging could not detect parathyroid adenomas with an axial diameter of 1.0 to 1.2 cm. Four out of 10 (40%) hyperplastic parathyroid glands were diagnosed, using planar and SPECT imaging and 5 out of 10 (50%) hyperplastic parathyroid glands were localized, using SPECT/CT fusion images. SPECT/CT fusion imaging is a more useful tool for localization of parathyroid lesions, particularly parathyroid adenomas, in comparison with planar and or SPECT imaging

  20. Effect of post-myocardial infarction streptokinase (sk) therapy, on myocardial viability - evaluation with thallium-201 single photon emission computed tomography (TL-201 SPECT)

    International Nuclear Information System (INIS)

    Shaikh, M.S.; Raza, M.; Kayani, A.M.; Fazal, I.

    2011-01-01

    To evaluate the effect of post-myocardial infarction Streptokinase therapy on myocardial viability, employing Thallium-201 single photon emission computed tomography (TL-201 SPECT). Design: Retrospective, experimental study. Place and duration of study: The Nuclear Cardiology Department, Armed Forces Institute of Cardiology / National Institute of Heart Diseases, Rawalpindi, from 1 April, 2009 to 31 October, 2009. Patients and Methods: Male patients, who had suffered from acute myocardial infarction (AMI), in an area supplied by the left anterior descending (LAD) artery, had infarct-related electrocardiogram (ECG) changes and received or did not receive Streptokinase therapy, were included. Those with a normal ECG, or history of revascularisation, or non-ST elevation MI, or more than one MIs, were excluded. The patients were divided into groups 1 (who received Streptokinase) and 2 (who did not receive Streptokinase). Each group contained 42 patients and all underwent scintigraphic viability study through intravenous injection of 3.0 mCi (123 MBq) of TL-201, followed by rest-redistribution SPECT imaging on a dual head, dedicated cardiac gamma camera system (Philips Cardio MD). Emory's cardiac toolbox and AutoQUANT were used for data processing and quantitative estimation of viable myocardium. Empirical scores from 0 to 2 were assigned to each of the scans, in the order of increasing viability, and these were compared across the two groups. Result: Group 1 contained 42 patients (age range = 38 to 80 years, mean = 53.98 +- 11.26 years), in whom empirical viability scoring was done. Score 0 was seen in 2 patients, score 1 was seen in 15 patients and score 2 was seen in 25 patients form this group. Group 2 also contained 42 patients (age range = 38 to 80 years, mean = 56.71 +- 9.05 years), in whom viability score of 0 was seen in 3 patients, score 1 was seen in 11 patients and score 2 was seen in 28 patients form this group. Age difference between the two groups was

  1. Significance of exercise-induced ST segment depression in patients with myocardial infarction involving the left circumflex artery. Evaluation by exercise thallium-201 myocardial single photon emission computed tomography

    International Nuclear Information System (INIS)

    Koitabashi, Norimichi; Toyama, Takuji; Hoshizaki, Hiroshi

    2000-01-01

    The significance of exercise-induced ST segment depression in patients with left circumflex artery involvement was investigated by comparing exercise electrocardiography with exercise thallium-201 single photon emission computed tomography (Tl-SPECT) and the wall motion estimated by left ventriculography. Tl-SPECT and exercise electrocardiography were simultaneously performed in 51 patients with left circumflex artery involvement (angina pectoris 30, myocardial infarction 21). In patients with myocardial infarction, exercise-induced ST depression was frequently found in the V 2 , V 3 and V 4 leads. In patients with angina pectoris, ST depression was frequently found in the II, III, aV F , V 5 and V 6 leads. There was no obvious difference in the leads of ST depression in patients with myocardial infarction with ischemia and without ischemia on Tl-SPECT images. In patients with myocardial infarction, the lateral wall motion of the infarcted area evaluated by left ventriculography was more significantly impaired in the patients with ST depression than without ST depression (p<0.01). Exercise-induced ST depression in the precordial leads possibly reflects wall motion abnormality rather than ischemia in the lateral infarcted myocardium. (author)

  2. Utility of SPECT imaging for determination of vertebral metastases in patients with known primary tumors

    International Nuclear Information System (INIS)

    Bushnell, D.L.; Kahn, D.; Huston, B.; Bevering, C.G.

    1995-01-01

    Determining the etiology of a focal lesion seen on bone scan in patients with primary tumors usually requires the use of other imaging procedures or biopsy. Single positron emission computed tomography (SPECT) with high resolution multidetector systems can localize the specific site of a vertebral lesion and in this way potentially differentiate between benign and metastatic disease. SPECT images of the lower thoracic and lumbar spine were reviewed for lesion location and intensity by two experienced interpreters. Follow-up data were adequate to ascertain the cause of 71 lesions seen on SPECT in 29 patients. Twenty-six of these lesions were not seen on planar images. Of the 71 lesions, 44 were benign and 27 metastatic. Of the 15 lesions where the pedicle was involved, 11 were found to metastatic. There were a total of 14 facet lesions, 9 of which were present in vertebra with no lesions at sites other than the facets. All 9 of these isolated facet lesions turned out to be benign. Lesion intensity did not distinguish benign from malignant disease. We conclude that SPECT imaging is useful in determining the etiology of focal lesions seen on bone scan in patients with a known primary tumor referred for evaluation of metastatic disease. (orig.)

  3. Prognostic value of dipyridamole thallium scintigraphy for evaluation of ischemic heart disease

    International Nuclear Information System (INIS)

    Hendel, R.C.; Layden, J.J.; Leppo, J.A.

    1990-01-01

    Exercise testing alone or in combination with thallium scintigraphy has significant prognostic value. In contrast, dipyridamole thallium imaging is not dependent on patients achieving adequate levels of exercise, but no long-term prognostic studies have been reported. Accordingly, imaging results of 516 consecutive patients referred for dipyridamole thallium studies were correlated with subsequent cardiac events, death (n = 23) and myocardial infarction (n = 43) over a mean follow-up period of 21 months. Patients with a history of congestive heart failure, prior myocardial infarction, diabetes mellitus or abnormal scans were significantly more likely to have a cardiac event (p less than 0.03). With use of logistic regression analysis, an abnormal scan was an independent and significant predictor of subsequent myocardial infarction or cardiac death and increased the relative risk of any event more than threefold. The presence of redistribution on thallium scanning further increased the risk of a cardiac event. Survival analysis demonstrated a significant difference between patients with an abnormal or normal thallium scan over a 30 month period. In conclusion, dipyridamole thallium scintigraphy demonstrates prognostic value in a large unselected population and may be an adequate clinical alternative to physiologic exercise testing in the evaluation of coronary heart disease

  4. Detection of coronary artery disease using 12-lead electrocardiogram and simultaneous dual myocardial imaging with iodine-123-β-methyl iodophenyl-pentadecanoic acid (BMIPP) and thallium-201 in patients with unstable angina

    International Nuclear Information System (INIS)

    Saitoh, Makoto; Hasegawa, Koh; Hasegawa, Kazuo; Kondoh, Teruo; Yanagawa, Tetsuo.

    1995-01-01

    We investigated the usefulness of 12-lead electrocardiogram and simultaneous single-photon emission computed tomography (SPECT) with 123 I-β-methyl iodophenyl-pentadecanoic acid (BMIPP) and thallium-201 ( 201 Tl) for detecting coronary artery disease (CAD) in 54 consecutive patients with unstable angina. Discordant BMIPP uptake was defined as less 123 I-BMIPP uptake than 201 Tl uptake in 123 I-BMIPP/ 201 Tl dual SPECT. In the detection of CAD, ischemic electrocardiographic change during anginal attack had high sensitivity and low specificity, while discordant BMIPP finding had low sensitivity and high specificity. In patients showing ST depression during anginal attack, discordant BMIPP uptake showed high sensitivity and high specificity for detecting CAD. In conclusion, both 12-lead electrocardiogram during anginal attack and discordant BMIPP uptake are useful in detecting CAD in patients with unstable angina. (author)

  5. Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT

    International Nuclear Information System (INIS)

    Matsutomo, Norikazu; Nagaki, Akio; Sasaki, Masayuki

    2014-01-01

    IQ-SPECT is an advanced high-speed SPECT modality for myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQ-SPECT with conventional SPECT in terms of performance, based on standard clinical protocols. In addition, we examined the concordance between conventional and IQ-SPECT in patients with coronary artery disease (CAD). Fifty-three patients, undergoing rest-gated MPI for the evaluation of known or suspected CAD, were enrolled in this study. In each patient, conventional SPECT ( 99m Tc-tetrofosmin, 9.6 min and 201 Tl, 12.9 min) was performed, immediately followed by IQ-SPECT, using a short acquisition time (4.3 min for 99m Tc-tetrofosmin and 6.2 min for 201 Tl). A quantitative analysis was performed on an MPI polar map, using a 20-segment model of the left ventricle. An automated analysis by gated SPECT was carried out to determine the left ventricular volume and function including end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF). The degree of concordance between conventional SPECT and IQ-SPECT images was evaluated according to linear regression and Bland-Altman analyses. The segmental percent uptake exhibited a significant correlation between IQ-SPECT and conventional SPECT (P<0.05). The mean differences in 99m Tc-tetrofosmin studies were 1.1±6.6% (apex), 2.8±5.7% (anterior wall), 2.9±6.2% (septal wall), 4.9±6.7% (lateral wall), and 1.8±5.6% (inferior wall). Meanwhile, regarding the 201 Tl-SPECT studies, these values were 1.6±6.9%, 2.0±6.6%, 2.1±5.9%, 3.3±7.2%, and 2.4±5.8%, respectively. Although the mean LVEF in IQ-SPECT tended to be higher than that observed in conventional SPECT (conventional SPECT=64.8±11.8% and IQ-SPECT=68.3±12.1% for 99m Tc-tetrofosmin; conventional SPECT= 56.0±11.7% and IQ-SPECT=61.5±12.2% for 201 Tl), quantitative parameters were not significantly different between

  6. Fusion imaging of computed tomographic pulmonary angiography and SPECT ventilation/perfusion scintigraphy: initial experience and potential benefit

    International Nuclear Information System (INIS)

    Harris, Benjamin; Bailey, Dale; Roach, Paul; Bailey, Elizabeth; King, Gregory

    2007-01-01

    The objective of this study was to examine the feasibility of fusing ventilation and perfusion data from single-photon emission computed tomography (SPECT) ventilation perfusion (V/Q) scintigraphy together with computed tomographic pulmonary angiography (CTPA) data. We sought to determine the accuracy of this fusion process. In addition, we correlated the findings of this technique with the final clinical diagnosis. Thirty consecutive patients (17 female, 13 male) who had undergone both CTPA and SPECT V/Q scintigraphy during their admission for investigation of potential pulmonary embolism were identified retrospectively. Image datasets from these two modalities were co-registered and fused using commercial software. Accuracy of the fusion process was determined subjectively by correlation between modalities of the anatomical boundaries and co-existent pleuro-parenchymal abnormalities. In all 30 cases, SPECT V/Q images were accurately fused with CTPA images. An automated registration algorithm was sufficient alone in 23 cases (77%). Additional linear z-axis scaling was applied in seven cases. There was accurate topographical co-localisation of vascular, parenchymal and pleural disease on the fused images. Nine patients who had positive CTPA performed as an initial investigation had co-localised perfusion defects on the subsequent fused CTPA/SPECT images. Three of the 11 V/Q scans initially reported as intermediate could be reinterpreted as low probability owing to co-localisation of defects with parenchymal or pleural pathology. Accurate fusion of SPECT V/Q scintigraphy to CTPA images is possible. This technique may be clinically useful in patients who have non-diagnostic initial investigations or in whom corroborative imaging is sought. (orig.)

  7. Applications of SPECT imaging of dopaminergic neurotransmission in neuropsychiatric disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kugaya, Akira; Fujita, Masahiro; Innis, R.B. [Yale Univ., New Haven, CT (United States). School of Medicine

    2000-02-01

    Single photon emission computed tomography (SPECT) tracers selective for pre- and post-synaptic targets have allowed measurements of several aspects of dopaminergic (DA) neurotransmission. In this article, we will first review our DA transporter imaging in Parkinson's disease. We have developed the in vivo dopamine transporter (DAT) imaging with [{sup 123}I]{beta}-CIT ((1R)-2{beta}-Carbomethoxy-3{beta}-(4-iodophenyl)tropane). This method showed that patients with Parkinson's disease have markedly reduced DAT levels in striatum, which correlated with disease severity and disease progression. Second, we applied DA imaging techniques in patients with schizophrenia. Using amphetamine as a releaser of DA, we observed the enhanced DA release, which was measured by imaging D2 receptors with [{sup 123}I]IBZM (iodobenzamide), in schizophrenics. Further we developed the measurement of basal synaptic DA levels by AMPT (alpha-methyl-paratyrosine)-induced unmasking of D2 receptors. Finally, we expanded our techniques to the measurement of extrastriatal DA receptors using [{sup 123}I]epidepride. The findings suggest that SPECT is a useful technique to measure DA transmission in human brain and may further our understanding of the pathophysiology of neuropsychiatric disorders. (author)

  8. Cervical SPECT Camera for Parathyroid Imaging

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2012-08-31

    Primary hyperparathyroidism characterized by one or more enlarged parathyroid glands has become one of the most common endocrine diseases in the world affecting about 1 per 1000 in the United States. Standard treatment is highly invasive exploratory neck surgery called Parathyroidectomy. The surgery has a notable mortality rate because of the close proximity to vital structures. The move to minimally invasive parathyroidectomy is hampered by the lack of high resolution pre-surgical imaging techniques that can accurately localize the parathyroid with respect to surrounding structures. We propose to develop a dedicated ultra-high resolution (~ 1 mm) and high sensitivity (10x conventional camera) cervical scintigraphic imaging device. It will be based on a multiple pinhole-camera SPECT system comprising a novel solid state CZT detector that offers the required performance. The overall system will be configured to fit around the neck and comfortably image a patient.

  9. Role of exercise thallium-201 myocardial perfusion scintigraphy in predicting prognosis in suspected coronary artery disease

    International Nuclear Information System (INIS)

    Koss, J.H.; Kobren, S.M.; Grunwald, A.M.; Bodenheimer, M.M.

    1987-01-01

    While exercise thallium imaging has improved sensitivity and specificity for detection of coronary artery disease (CAD), its predictive value for morbid cardiac events is unclear. Of 532 consecutive patients who underwent exercise thallium imaging, follow-up was complete in 515 (97%) after an average of 36 months (range 31 to 48). Two hundred six patients had an abnormal exercise thallium response and 309 had a normal response. Twenty morbid cardiac events occurred (13 deaths and 7 acute myocardial infarctions [AMI]). Of the 13 patients who died, 12 had abnormal thallium results. Overall, 5.8% of the patients with abnormal thallium results died, in contrast to 0.3% of patients with normal results. Of the 7 patients who had a nonfatal AMI, 3 had abnormal exercise thallium results. Moreover, similar proportions of patients (1.4% and 1.3%) with normal and abnormal exercise thallium results had nonfatal AMI. Presence or absence of pathologic Q waves and inclusion of exercise electrocardiographic results did not significantly alter the results. Thus, although a normal exercise thallium response significantly reduces the likelihood of cardiovascular death, its predictive value for nonfatal AMI is limited. Moreover, the relatively low event rate for patients with a positive exercise thallium response further limits its prognostic value

  10. Thallium-201 exercise myocardial imaging to evaluate myocardial perfusion after coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Hirzel, H.O.; Nuesch, K.; Sialer, G.; Horst, W.; Krayenbuehl, H.P.

    1980-01-01

    To assess the usefulness of thallium-201 exercise scintigraphy in evaluating myocardial perfusion after coronary artery bypass surgery, imaging was performed after submaximal bicycle ergometry and at rest in 54 patients before and within 24 +- 10 (SD) weeks after operation. Scintigraphy identified 8 out of 20 patients who were symptom free after operation and showed normal exercise electrocardiograms as still having exercise-induced ischaemia and thus as having not truly benefited from the surgical intervention. In contrast, improvement in perfusion was documented in 17 out of 31 patients despite further complaints of chest pain and persistence of a pathological exercise electrocardiogram in 6 of them. Bypass graft patency rate paralleled the scintigraphic findings in the 35 patients who were restudied arteriographically. It was concluded that thallium-201 exercise scintigraphy is a useful technique to document changes in regional perfusion after surgery and is definitely superior to the clinical evaluation of patients including the exercise electrocardiogram. (author)

  11. Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator

    International Nuclear Information System (INIS)

    Du, Yong; Frey, Eric C; Bhattacharya, Manojeet

    2014-01-01

    Simultaneous dual-radionuclide myocardial perfusion/innervation SPECT imaging can provide important information about the mismatch between scar tissue and denervated regions. The Siemens IQ-SPECT system developed for cardiac imaging uses a multifocal SMARTZOOM collimator to achieve a four-fold sensitivity for the cardiac region, compared to a typical parallel-hole low-energy high-resolution collimator, but without the data truncation that can result with conventional converging-beam collimators. The increased sensitivity allows shorter image acquisition times or reduced patient dose, making IQ-SPECT ideal for simultaneous dual-radionuclide SPECT, where reduced administrated activity is desirable in order to reduce patient radiation exposure. However, crosstalk is a major factor affecting the image quality in dual-radionuclide imaging. In this work we developed a model-based method that can estimate and compensate for the crosstalk in IQ-SPECT data. The crosstalk model takes into account interactions in the object and collimator-detector system. Scatter in the object was modeled using the effective source scatter estimation technique (ESSE), previously developed to model scatter with parallel-hole collimators. The geometric collimator-detector response was analytically modeled in the IQ-SPECT projector. The estimated crosstalk was then compensated for in an iterative reconstruction process. The new method was validated with data from both Monte Carlo simulations and physical phantom experiments. The results showed that the estimated crosstalk was in good agreement with simulated and measured results. After model-based compensation the images from simultaneous dual-radionuclide acquisitions were similar in quality to those from single-radionuclide acquisitions that did not have crosstalk contamination. The proposed model-based method can be used to improve simultaneous dual-radionuclide images acquired using IQ-SPECT. This work also demonstrates that ESSE scatter

  12. Analysis of the degree of pulmonary thallium washout after exercise in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Levy, R.; Rozanski, A.; Berman, D.S.; Garcia, E.; Van Train, K.; Maddahi, J.; Swan, H.J.

    1983-01-01

    An abnormal increase in pulmonary thallium activity may be visualized on post-stress thallium images in patients with coronary artery disease. Because this increased pulmonary thallium activity usually disappears by the time of redistribution imaging, this study was designed to assess whether measurement of the degree of pulmonary thallium washout between stress and redistribution might improve the detection of increased pulmonary thallium activity in patients with coronary artery disease. Quantitative analysis revealed abnormal (that is, greater than 2 standard deviations of normal values) pulmonary thallium washouts in 59 (64%) of 92 patients with coronary artery disease, but in only 2 (25%) of 8 subjects with angiographically normal arteries (p less than 0.06). By comparison, the visual analysis of pulmonary thallium washout and use of initial pulmonary to myocardial thallium ratio were significantly (p less than 0.05) less sensitive in detecting abnormality in patients with coronary artery disease. Abnormal pulmonary thallium washout was related to both the anatomic extent and functional severity of disease: it occurred with greatest frequency in patients with multivessel disease and in those with exercise-induced left ventricular dysfunction (p less than 0.005). When added to the quantitative analysis of myocardial scintigraphy, the analysis of pulmonary thallium washout increased the detection of coronary artery disease from 84 to 93% (p less than 0.05), but the sample size was too small to assess specificity

  13. Influence of peak exercise heart rate on normal thallium-201 myocardial clearance

    International Nuclear Information System (INIS)

    Kaul, S.; Chesler, D.A.; Pohost, G.M.; Strauss, H.W.; Okada, R.D.; Boucher, C.A.

    1986-01-01

    Measurement of myocardial clearance rates between initial and delayed images is a major justification for adding computer quantification to the interpretation of exercise 201 TI images. To clarify the range of normal thallium clearance and its relationship to the level of exercise achieved, exercise thallium images in 89 normal subjects were analyzed: 45 asymptomatic subjects with less than 1% probability of coronary artery disease (CAD) (Group I), and 44 patients with chest pain found to have no significant CAD on angiography (Group II). Mean initial regional thallium uptake was similar in the two groups, but myocardial thallium clearance (mean +/- 1 s.d.) was slower in Group II, expressed as a longer half-life in the myocardium (8.2 +/- 7.6 hr compared with 3.4 +/- 0.7 hr p less than 0.001). Analysis of variance using ten clinical and exercise variables as covariates showed that the slower clearance in Group II was related to a lower peak exercise heart rate (HR) (154 +/- 27 compared with 183 +/- 11, respectively, p less than 0.001). By linear regression analysis, a decrease in peak HR of 1 beat/min was associated with a slower thallium clearance (longer half-life) of 0.05 hr. Using this formula, the clearance value in each patient was then corrected for peak exercise heart rate by decreasing measured clearance by 0.05 hr multiplied by the amount peak exercise heart rate which was below 183 (the mean value in Group I). There were no differences in the corrected clearance between the two groups. We conclude that thallium myocardial clearance after exercise is related in part to factors other than the presence of CAD, being slower when peak exercise HR is lower. Therefore, thallium clearance rates alone uncorrected for peak exercise heart rate should be used with caution when diagnosing CAD

  14. Detection of viability by percent thallium uptake with conventional thallium scintigraphy

    International Nuclear Information System (INIS)

    Imai, Kamon; Araki, Yasushi; Horiuchi, Kou-ichi; Yumikura, Sei; Saito, Satoshi; Ozawa, Yukio; Kan-matsuse, Katsuo; Hagiwara, Kazuo.

    1994-01-01

    Thallium myocardial scintigraphy (TMS) is used for diagnosis of viability in infarcted myocardium before coronary revascularization. Underestimation of viability by TMS has been reported by many investigators. To evaluate viability precisely, thallium re-injection method or 24 hour delayed imaging is performed. However, these techniques are not convenient and are difficult to perform in clinical practice. Percent T1-uptake method was developed for predicting myocardial viability. To evaluate usefulness of this method, TMS was performed before and after PTCA in 23 patients with myocardial infarction. Left ventricle was divided into 3 layers, then each layer was divided into 4 segments (12 segments in total). Forth three segments showed recovery of perfusion on TMS after PTCA. Viability in infarcted myocardium is predicted by 1) redistribution (RD), 2) %T1-uptake≥45% on the image immediately after exercise (TE), and 3) %T1-uptake≥45% on delayed image (TD). Sensitivity was RD: 60%, TE: 90% and TD: 95% (p<0.001 vs. RD). Specificity was RD: 74%, TE: 68%, and TD: 60% (NS). Predictive accuracy (PA) was RD: 69%, TE: 77%, TD: 73% (NS). Compared with RD, %T1-uptake, either TE or TD, increased sensitivity with slightly improved PA, but decreased specificity slightly. Therefore %T1-uptake would be a sensitive and useful predictor to find patients who are most likely to benefit from re-vascularization. (author)

  15. Initial experience with SPECT imaging of the brain using I-123 p-iodoamphetamine in focal epilepsy

    International Nuclear Information System (INIS)

    LaManna, M.M.; Sussman, N.M.; Harner, R.N.

    1989-01-01

    Nineteen patients with complex partial seizures refractory to medical treatment were examined with routine electroencephalography (EEG), video EEG monitoring, computed tomography or magnetic resonance imaging, neuropsychological tests and interictal single photon emission computed tomography (SPECT) with I-123 iodoamphetamine (INT). In 18 patients, SPECT identified areas of focal reduction in tracer uptake that correlated with the epileptogenic focus identified on the EEG. In addition, SPECT disclosed other areas of neurologic dysfunction as elicited on neuropsychological tests. Thus, IMP SPECT is a useful tool for localizing epileptogenic foci and their associated dynamic deficits

  16. Clinical Utility of SPECT/CT Imaging Post-Radioiodine Therapy: Does It Enhance Patient Management in Thyroid Cancer?

    Science.gov (United States)

    Hassan, Fahim U; Mohan, Hosahalli K

    2015-12-01

    The aim of this study was to evaluate post-therapy iodine-131 single-photon emission computed tomography/computed tomography ((131)I-SPECT/CT) imaging in comparison to conventional planar (131)I whole-body imaging, and to assess its clinical impact on the management of patients. We retrospectively reviewed planar (131)I whole-body and (131)I-SPECT/CT imaging findings in 67 patients who underwent (131)I therapy for thyroid cancer. Two nuclear medicine physicians reviewed the scans independently. The foci of increased tracer uptake were identified in the neck, thorax and elsewhere. Within the neck, the foci of (131)I-increased uptake were graded qualitatively as probable or definite uptake in thyroid remnants and probable or definite uptake in the lymph nodes. Serum thyroglobulin level, histopathology and other imaging findings served as the reference standard. Of the 67 patients, 57 (85%) had radioiodine avid disease and 10 (15%) demonstrated non-radioiodine avid disease. Overall, post-therapy (131)I-SPECT/CT downstaged lymph node staging in 10 patients and upstaged it in 4 patients. This translated into a change of management for 9/57 (16%) patients with radioiodine avid disease. A change of management was observed in 5/10 patients with non-radioiodine avid disease confirmed in the post-(131)I-SPECT/CT study. Additionally, clinically significant findings such as incidental lung cancer, symptomatic pleural effusion and consolidation were also diagnosed in both groups of patients. In patients with thyroid cancer, (131)I-SPECT/CT is a valuable addition to standard post-therapy planar imaging. SPECT/CT also improved diagnostic confidence and provided crucial clinical information leading to change of management for a significant number of these patients.

  17. SPECT in psychiatry

    International Nuclear Information System (INIS)

    Barocka, A.; Feistel, H.; Ebert, D.; Lungershausen, E.

    1993-01-01

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D 2 and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.) [de

  18. Comparison of thallium-201 and gallium-67 scintigraphy in soft tissue and bone marrow multiple myeloma: a case report

    International Nuclear Information System (INIS)

    Roach, P.J.; Arthur, C.K.

    1997-01-01

    A 68 year old female was referred for assessment of multiple myeloma. A large myelomatous infiltrate involving the left triceps muscle showed avid uptake on both thallium-201 and gallium-67 scintigraphy. Following radiotherapy, imaging with both radiopharmaceuticals showed resolution of disease; however, tumour recurrence in the bone marrow was seen only on thallium-201 imaging. This observation suggests that while soft-tissue myleoma shows similar appearances on thallium-201 and gallium-67 scintigraphy, both at baseline and following therapy, gallium-67 may not demonstrate bone marrow infiltration which is visualized on thallium-201 imaging. Therefore, thallium-201 appears to be superior to gallium-67 in evaluation of patients with multiple myeloma when soft tissues and bone marrow are involved. 17 refs., 3 figs

  19. Myocardial rest iodine-123-β-methyl-iodophenyl-pentadecanoic acid scintigraphy compared with dipyridamole stress thallium-201 scintigraphy in unstable angina

    International Nuclear Information System (INIS)

    Misumi, Ikuo; Kimura, Yoshihiro; Hokamura, Youichi; Yamabe, Hiroshige; Ueno, Kazuhiro

    1998-01-01

    Twelve patients with stable angina and 12 patients with unstable angina underwent rest iodine-123-β-methyl-iodophenyl-pentadecanoic acid (BMIPP), dipyridamole stress thallium scintigraphy and delayed thallium scintigraphy. In stable angina, sensitivity for detecting ischemic segments was higher in dipyridamole thallium (74%) than rest BMIPP (48%) images (p<0.05), but there was no significant difference between the 2 images in unstable angina. In unstable angina, the incidence of segments with higher defect scores on BMIPP images than on delayed thallium images and the opposite pattern was 27 and 5 (p<0.01). In stable angina, there was no difference. The mean defect score on BMIPP (6.3±5.6) was higher than that on delayed thallium scintigraphy (2.9±2.7) and it was almost the same as on the initial dipyridamole stress test (6.5±5.2). In conclusion, BMIPP scintigraphy is safer and may be as useful in detecting myocardial ischemia in patients with unstable angina as thallium scintigraphy. (author)

  20. Thallium-201 scintigraphy for bone and soft tissue tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tokuumi, Yuji; Tsuchiya, Hiroyuki; Sunayama, Chiaki; Matsuda, Eizo; Asada, Naohiro; Taki, Junichi; Sumiya, Hisashi; Miyauchi, Tsutomu; Tomita, Katsuro [Kanazawa Univ. (Japan). School of Medicine

    1995-05-01

    This study was undertaken to assess the usefulness of thallium-201 scintigraphy in bone and soft tissue tumors. Pre-therapy scintigraphy was undertaken in a total of 136 patients with histologically confirmed diagnosis, consisting of 74 with malignant bone and soft tissue tumors, 39 with benign ones, 12 with diseases analogous to tumors, and 11 others. Thallium activity was graded on a scale of 0-4: 0=background activity, 1=equivocal activity, 2=definitive activity, but less than myocardium, 3=definite activity equal to myocardium, and 4=activity greater than myocardium. In the group of malignant tumors, thallium-201 uptake was found in 80%, although it was low for chondrosarcoma (2/8) and malignant Schwannoma (one/3). The group of benign tumors, however, showed it in only 41%, being restricted to those with giant cell tumors, chondroblastoma, fibromatosis, and osteoid osteoma. Thallium-201 uptake was also found in all 8 patients with metastatic tumors. In 23 patients undergoing thallium imaging before and after chemotherapy, scintigraphic findings revealed a high correlation with histopathological findings. Thus, thallium-201 scintigraphy may be potentially used to distinguish malignant from benign bone and soft tissue tumors, except for a few histopathological cases, as well as to determine loco-regional metastases and response to chemotherapy. (N.K.).

  1. The study of brain dopamine transporter 99Tcm-TRODAT-1 SPECT imaging

    International Nuclear Information System (INIS)

    Yang Jian; Su Min; Liu Xiuqian; Liang Weijuan; Zhao Bin; Xu Zhien

    2006-01-01

    Objective: To investigate the distribution character of 99 Tc m -2β-[N, N'-bis (2-mercaptoethyl) ethylenediamino] methyl, 3β-(4-chlorophenyl) tropane (TRODAT-1) in basal ganglia and the diagnostic value of SPECT imaging in Parkinson' s disease (PD). Methods: 99 Tc m -TRODAT-l SPECT imaging was performed in 30 PD patients and 16 age-matched healthy volunteers. Two semiquantitative analysis methods were used: (1)Striatum(ST)/cerebellum (CB) uptake ratio (ST/CB) was calculated by regions of interest (ROIs) in three transverse and sagittal slice. (2) ROIs were drawn manually on six subregions of both basal ganglia and also CB and occipital region(OC) as reference, and the corresponding uptake ratio of ROI/(OC + CB/2) was calculated. Results: The ST/CB in transverse and sagittal slice for the left and right were 1.55 ± 0.15, 1.58 ± 0.14 and 1.62 ± 0.17, 1.69 ± 0.16 respectively in healthy volunteers. The ST/CB and ROI/(OC + CB/2) in the basal ganglia of PD patients were significantly less than those of healthy volunteers (P 99 Tc m -TRODAT-1 SPECT imaging is an effective method in diagnosis of PD. (authors)

  2. Kit formulated asialoglycoprotein receptor targeting tracer based on copolymer for liver SPECT imaging.

    Science.gov (United States)

    Liu, Chang; Guo, Zhide; Zhang, Pu; Song, Manli; Zhao, Zuoquan; Wu, Xiaowei; Zhang, Xianzhong

    2014-08-01

    Specific targeting of galactose-carrying molecule to ASGP-R in normal hepatocytes has been demonstrated before. In this study, galactosyl polystyrene was synthesized from controllable ratio of functional monomers and radio-labelled with (99m)Tc by formulated kit for SPECT imaging of hepatic function. p(VLA-co-VNI)(46:54) was synthesized by free-radical copolymerization initiated by AIBN, purified by dialysis, lyophilized to kit with Tricine and TPPTS as co-ligands for (99m)Tc labeling. Radiotracer (99m)Tc-p(VLA-co-VNI)(46:54)(Tricine)(TPPTS) was prepared and evaluated by in vitro stability, in vivo metabolism, ex vivo biodistribution and microSPECT/CT imaging in normal KM mice. MicroSPECT/CT and microMRI imaging were also performed in C57BL/b6 mice with xenograft hepatic carcinoma for hepatic function evaluation. (99m)Tc-p(VLA-co-VNI)(46:54)(Tricine)(TPPTS) was obtained in high radio chemical purity (RCP) (>99%) by using instant kit without further purification and excellent in vitro and in vivo stability. The result of biodistribution showed that liver had high uptake (90.49±10.68 ID%/g) at 30 min after injection and was blocked significantly by cold copolymer. MicroSPECT imaging in normal KM mice at 1h and 4h after injection showed good liver retention and targeting properties. Significant defect of activity was observed in the tumor site which was confirmed by MRI imaging. (99m)Tc-p(VLA-co-VNI)(46:54)(Tricine)(TPPTS) with lower ratio of targeting moiety has no observable effect on the specific binding affinity and liver uptake. This makes it possible to introduce more imaging units for multi-modality imaging. Furthermore, the instant kit preparation of (99m)Tc-labeling provides great potential for the evaluation of hepatocyte function in clinical application. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Present assessment of myocardial viability by nuclear imaging.

    Science.gov (United States)

    Saha, G B; MacIntyre, W J; Brunken, R C; Go, R T; Raja, S; Wong, C O; Chen, E Q

    1996-10-01

    Prospective delineation of viable from nonviable myocardium in patients with coronary artery disease in an important factor in deciding whether a patient should be revascularized or treated medically. Two common techniques--single-photon emission computed tomography (SPECT) and positron-emission computed tomography (PET)--are used in nuclear medicine using various radiopharmaceuticals for the detection of myocardial viability in patients. Thallium-201 (201Tl) and technetium-99m (99mTc)-sestamibi are the common radiopharmaceuticals used in different protocols using SPECT, whereas fluoride-18 (18F)-fluorodeoxyglucose (FDG) and rubidium-82 (82Rb) are most widely used in PET. The SPECT protocols involve stress/redistribution, stress/redistribution/reinjection, and rest/redistribution imaging techniques. Many studies have compared the results of 201Tl and (99mTc)-sestamibi SPECT with those of FDG PET; in some studies, concordant results have been found between delayed thallium and FDG results, indicating that 201Tl, although considered a perfusion agent, shows myocardial viability. Discordant results in a number of studies have been found between sestamibi and FDG, suggesting that the efficacy of sestamibi as a viability marker has yet to be established. Radiolabeled fatty acids such as iodine-123 (123I)-para-iodophenylpentadecanoic acid and carbon-11 (11C)-palmitic acid have been used for the assessment of myocardial viability with limited success. 11C-labeled acetate is a good marker of oxidative metabolism in the heart and has been used to predict the reversibility of wall motion abnormalities. (18F)-FDG is considered the marker of choice for myocardial viability, although variable results are obtained under different physiological conditions. Detection of myocardial viability can be greatly improved by developing new equipment and radiopharmaceuticals of better quality.

  4. Automated MicroSPECT/MicroCT Image Analysis of the Mouse Thyroid Gland.

    Science.gov (United States)

    Cheng, Peng; Hollingsworth, Brynn; Scarberry, Daniel; Shen, Daniel H; Powell, Kimerly; Smart, Sean C; Beech, John; Sheng, Xiaochao; Kirschner, Lawrence S; Menq, Chia-Hsiang; Jhiang, Sissy M

    2017-11-01

    The ability of thyroid follicular cells to take up iodine enables the use of radioactive iodine (RAI) for imaging and targeted killing of RAI-avid thyroid cancer following thyroidectomy. To facilitate identifying novel strategies to improve 131 I therapeutic efficacy for patients with RAI refractory disease, it is desired to optimize image acquisition and analysis for preclinical mouse models of thyroid cancer. A customized mouse cradle was designed and used for microSPECT/CT image acquisition at 1 hour (t1) and 24 hours (t24) post injection of 123 I, which mainly reflect RAI influx/efflux equilibrium and RAI retention in the thyroid, respectively. FVB/N mice with normal thyroid glands and TgBRAF V600E mice with thyroid tumors were imaged. In-house CTViewer software was developed to streamline image analysis with new capabilities, along with display of 3D voxel-based 123 I gamma photon intensity in MATLAB. The customized mouse cradle facilitates consistent tissue configuration among image acquisitions such that rigid body registration can be applied to align serial images of the same mouse via the in-house CTViewer software. CTViewer is designed specifically to streamline SPECT/CT image analysis with functions tailored to quantify thyroid radioiodine uptake. Automatic segmentation of thyroid volumes of interest (VOI) from adjacent salivary glands in t1 images is enabled by superimposing the thyroid VOI from the t24 image onto the corresponding aligned t1 image. The extent of heterogeneity in 123 I accumulation within thyroid VOIs can be visualized by 3D display of voxel-based 123 I gamma photon intensity. MicroSPECT/CT image acquisition and analysis for thyroidal RAI uptake is greatly improved by the cradle and the CTViewer software, respectively. Furthermore, the approach of superimposing thyroid VOIs from t24 images to select thyroid VOIs on corresponding aligned t1 images can be applied to studies in which the target tissue has differential radiotracer retention

  5. Determination of Three-Dimensional Left Ventricle Motion to Analyze Ventricular Dyssyncrony in SPECT Images

    DEFF Research Database (Denmark)

    de Sá Rebelo, Marina; Aarre, Ann Kirstine Hummelgaard; Clemmesen, Karen-Louise

    2010-01-01

    A method to compute three-dimension (3D) left ventricle (LV) motion and its color coded visualization scheme for the qualitative analysis in SPECT images is proposed. It is used to investigate some aspects of Cardiac Resynchronization Therapy (CRT). The method was applied to 3D gated-SPECT images...... sets from normal subjects and patients with severe Idiopathic Heart Failure, before and after CRT. Color coded visualization maps representing the LV regional motion showed significant difference between patients and normal subjects. Moreover, they indicated a difference between the two groups...

  6. TH-C-17A-06: A Hardware Implementation and Evaluation of Robotic SPECT: Toward Molecular Imaging Onboard Radiation Therapy Machines

    International Nuclear Information System (INIS)

    Yan, S; Touch, M; Bowsher, J; Yin, F; Cheng, L

    2014-01-01

    Purpose: To construct a robotic SPECT system and demonstrate its capability to image a thorax phantom on a radiation therapy flat-top couch. The system has potential for on-board functional and molecular imaging in radiation therapy. Methods: A robotic SPECT imaging system was developed utilizing a Digirad 2020tc detector and a KUKA KR150-L110 robot. An imaging study was performed with the PET CT Phantom, which includes 5 spheres: 10, 13, 17, 22 and 28 mm in diameter. Sphere-tobackground concentration ratio was 6:1 of Tc99m. The phantom was placed on a flat-top couch. SPECT projections were acquired with a parallel-hole collimator and a single pinhole collimator. The robotic system navigated the detector tracing the flat-top table to maintain the closest possible proximity to the phantom. For image reconstruction, detector trajectories were described by six parameters: radius-of-rotation, x and z detector shifts, and detector rotation θ, tilt ϕ and twist γ. These six parameters were obtained from the robotic system by calibrating the robot base and tool coordinates. Results: The robotic SPECT system was able to maneuver parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector-to-COR (center-ofrotation) distance. In acquisitions with background at 1/6th sphere activity concentration, photopeak contamination was heavy, yet the 17, 22, and 28 mm diameter spheres were readily observed with the parallel hole imaging, and the single, targeted sphere (28 mm diameter) was readily observed in the pinhole region-of-interest (ROI) imaging. Conclusion: Onboard SPECT could be achieved by a robot maneuvering a SPECT detector about patients in position for radiation therapy on a flat-top couch. The robot inherent coordinate frame could be an effective means to estimate detector pose for use in SPECT image reconstruction. PHS/NIH/NCI grant R21-CA156390-01A1

  7. The effect of acquisition interval and spatial resolution on dynamic cardiac imaging with a stationary SPECT camera

    International Nuclear Information System (INIS)

    Roberts, J; Maddula, R; Clackdoyle, R; DiBella, E; Fu, Z

    2007-01-01

    The current SPECT scanning paradigm that acquires images by slow rotation of multiple detectors in body-contoured orbits around the patient is not suited to the rapid collection of tomographically complete data. During rapid image acquisition, mechanical and patient safety constraints limit the detector orbit to circular paths at increased distances from the patient, resulting in decreased spatial resolution. We consider a novel dynamic rotating slant-hole (DyRoSH) SPECT camera that can collect full tomographic data every 2 s, employing three stationary detectors mounted with slant-hole collimators that rotate at 30 rpm. Because the detectors are stationary, they can be placed much closer to the patient than is possible with conventional SPECT systems. We propose that the decoupling of the detector position from the mechanics of rapid image acquisition offers an additional degree of freedom which can be used to improve accuracy in measured kinetic parameter estimates. With simulations and list-mode reconstructions, we consider the effects of different acquisition intervals on dynamic cardiac imaging, comparing a conventional three detector SPECT system with the proposed DyRoSH SPECT system. Kinetic parameters of a two-compartment model of myocardial perfusion for technetium-99m-teboroxime were estimated. When compared to a conventional SPECT scanner for the same acquisition periods, the proposed DyRoSH system shows equivalent or reduced bias or standard deviation values for the kinetic parameter estimates. The DyRoSH camera with a 2 s acquisition period does not show any improvement compared to a DyRoSH camera with a 10 s acquisition period

  8. The effect of acquisition interval and spatial resolution on dynamic cardiac imaging with a stationary SPECT camera

    Science.gov (United States)

    Roberts, J.; Maddula, R.; Clackdoyle, R.; Di Bella, E.; Fu, Z.

    2007-08-01

    The current SPECT scanning paradigm that acquires images by slow rotation of multiple detectors in body-contoured orbits around the patient is not suited to the rapid collection of tomographically complete data. During rapid image acquisition, mechanical and patient safety constraints limit the detector orbit to circular paths at increased distances from the patient, resulting in decreased spatial resolution. We consider a novel dynamic rotating slant-hole (DyRoSH) SPECT camera that can collect full tomographic data every 2 s, employing three stationary detectors mounted with slant-hole collimators that rotate at 30 rpm. Because the detectors are stationary, they can be placed much closer to the patient than is possible with conventional SPECT systems. We propose that the decoupling of the detector position from the mechanics of rapid image acquisition offers an additional degree of freedom which can be used to improve accuracy in measured kinetic parameter estimates. With simulations and list-mode reconstructions, we consider the effects of different acquisition intervals on dynamic cardiac imaging, comparing a conventional three detector SPECT system with the proposed DyRoSH SPECT system. Kinetic parameters of a two-compartment model of myocardial perfusion for technetium-99m-teboroxime were estimated. When compared to a conventional SPECT scanner for the same acquisition periods, the proposed DyRoSH system shows equivalent or reduced bias or standard deviation values for the kinetic parameter estimates. The DyRoSH camera with a 2 s acquisition period does not show any improvement compared to a DyRoSH camera with a 10 s acquisition period.

  9. Objective evaluation of reconstruction methods for quantitative SPECT imaging in the absence of ground truth.

    Science.gov (United States)

    Jha, Abhinav K; Song, Na; Caffo, Brian; Frey, Eric C

    2015-04-13

    Quantitative single-photon emission computed tomography (SPECT) imaging is emerging as an important tool in clinical studies and biomedical research. There is thus a need for optimization and evaluation of systems and algorithms that are being developed for quantitative SPECT imaging. An appropriate objective method to evaluate these systems is by comparing their performance in the end task that is required in quantitative SPECT imaging, such as estimating the mean activity concentration in a volume of interest (VOI) in a patient image. This objective evaluation can be performed if the true value of the estimated parameter is known, i.e. we have a gold standard. However, very rarely is this gold standard known in human studies. Thus, no-gold-standard techniques to optimize and evaluate systems and algorithms in the absence of gold standard are required. In this work, we developed a no-gold-standard technique to objectively evaluate reconstruction methods used in quantitative SPECT when the parameter to be estimated is the mean activity concentration in a VOI. We studied the performance of the technique with realistic simulated image data generated from an object database consisting of five phantom anatomies with all possible combinations of five sets of organ uptakes, where each anatomy consisted of eight different organ VOIs. Results indicate that the method provided accurate ranking of the reconstruction methods. We also demonstrated the application of consistency checks to test the no-gold-standard output.

  10. Incremental value of 99mTc-HYNIC-TOC SPECT/CT over whole-body planar scintigraphy and SPECT in patients with neuroendocrine tumours.

    Science.gov (United States)

    Trogrlic, Mate; Težak, Stanko

    2017-06-12

    The aim of this study was to evaluate the additional value of 99m Tc-HYNIC-TOC SPECT/CT over planar whole-body (WB) scintigraphy and SPECT alone in the detection and accurate localisation of neuroendocrine tumour (NET) lesions. This study included 65 patients with a definitive histological diagnosis of NET prior to scintigraphy. Planar WB scintigraphy, SPECT, and SPECT/CT images were acquired at 4 h post-administration of 670 MBq 99m Tc-HYNIC-TOC. Additional SPECT images at 10 min after tracer administration were also acquired. Clinical and imaging follow-up findings were considered as the reference standards (minimum follow-up period, 15 months). Patient and lesion-based analyses of the efficacies of the imaging modalities were performed. While 38 patients exhibited metastasis of NETs, 27 presented no evidence of metastasis. Upon patient-based analysis, the sensitivity and specificity of SPECT/CT were found to be 88.9 and 79.3 %, respectively. The diagnostic accuracies of WB scintigraphy, 4h-SPECT, and SPECT/CT were 72.3, 73.8, and 84.6 %, respectively. The area under curve (AUC) value for SPECT/CT (0.84) was the highest, followed by those for 4h-SPECT (0.75) and WB scintigraphy (0.74). The accuracy and AUC values of SPECT/CT were significantly better compared to those of WB scintigraphy (p < 0.001), 10 min-SPECT (p < 0.001), and 4 h-SPECT (p = 0.001). The findings of SPECT/CT led to the change in treatment plan of 11 patients (16.9 %). The sensitivity and diagnostic accuracy of SPECT/CT in the evaluation of NET lesions outperforms planar WB imaging or SPECT alone.

  11. Ocular melanoma: Detection using iodine-123-iodoamphetamine and SPECT imaging

    International Nuclear Information System (INIS)

    Dewey, S.H.; Leonard, J.C.

    1990-01-01

    Uptake of iodine-123-iodoamphetamine has been demonstrated in malignant melanoma using planar imaging techniques and has been used to detect an ocular melanoma at 12 hr postinjection. Using SPECT technique, an ocular melanoma is identified in a 64-yr-old male at 1 hr postinjection

  12. Intracoronary thallium-201 assessment of thrombolysis in acute myocardial infarction: a technique for imaging thallium distribution before and after therapy

    International Nuclear Information System (INIS)

    Parker, J.A.; Markis, J.E.; Silverman, K.J.

    1982-01-01

    Intracoronary administration of streptokinase during the acute phase of myocardial infarction results in recanalization of the occluded coronary artery in a high percentage of patients. A technique is developed to investigate the acute effect of thrombolysis on the perfusion to viable myocardium using intracoronary administration of thallium-201. With intracoronary administration a very small initial dose of thallium can be used. Thus, a second scan can be performed after therapy, using a normal dose with only minimal contribution from the baseline study

  13. Comparison of electrocardiography and thallium-201 myocardial scintigraphy for the detection of ergonovine-induced coronary artery spasm: angiographic correlation

    International Nuclear Information System (INIS)

    Shanes, J.G.; Pavel, D.; Blend, M.

    1987-01-01

    This study was performed to determine the sensitivity of thallium imaging vs ECG monitoring for detecting coronary artery spasm noninvasively following intravenous ergonovine administration as compared to simultaneous coronary angiography. Thirty-two patients with insignificant coronary artery disease and chest pain underwent 12-lead ECG monitoring, thallium imaging, and coronary arteriography following the administration of 0.05, 0.1, 0.2, and 0.3 mg of ergonovine given 5 minutes apart or until chest pain occurred. One minute following the last dose of ergonovine, 2.5 mCi of thallium-201 was injected intravenously, and a final ECG was recorded and repeat coronary arteriography performed. Within 10 minutes following the injection of thallium, imaging was performed in the 40-degree and 70-degree left anterior oblique and anterior projections. The ECG, thallium study, and coronary arteriogram were read blindly and results were compared. The ECG, angiogram, and thallium study were read as positive if the following occurred, respectively: greater than or equal to 1 mm ST segment elevation, depression, or T wave reversal; greater than 50% vessel narrowing,; and reversible perfusion defect. Five patients were excluded from analysis because of either catheter-induced spasm, suboptimal thallium studies, or protocol violations. Of the 27 patients included for analysis, six had chest pain, five had a positive angiogram, five had a positive thallium study, and one had a positive ECG. The sensitivity of thallium vs ECG monitoring was 80% vs 25%, and the accuracy was 92% vs 80%. We conclude that thallium imaging greatly increases the noninvasive detection of ergonovine-induced coronary spasm as compared with the ECG with no loss of accuracy

  14. Use of images of ictal-inter-ictal SPECT subtraction superimposed on MRI in pharmaco-resistant partial epilepsies in infants

    International Nuclear Information System (INIS)

    Vera, P.; Kaminska, A.; Cieuta, C.; Mangin, F.; Frouin, V.; Dulac, O.; Chiron, C.

    1997-01-01

    To study the significance of ictal SPECT in the pre-surgical examination of infant epilepsies we have explored 16 infants aged 3 months to 18 years presenting partial pharmaco-resistant epilepsy. All of them have had an ictal SPECT under EEG - video recording than, two days after, an inter-ictal SPECT coupled to a 3D cerebral MRI. The perfusion tracer, the 99m Tc - ECD, was injected in average at 15 seconds after the outset of crisis. The image processing implied a matching of the two SPECT examinations by a 3D rigid superposition method, a normalization and than a inter-ictal-ictal image subtraction. Finally, the subtraction was matched and superimposed on the MRI. The SPECT subtraction image showed one or several centres of ictal hyper-output in 15 patients, while the separated visual ictal and inter-ictal images were contributory in 8 cases only. The 16. infant presented very short crises (<10 sec). In the cases when the outset point of crises could be established clinically (12 cases) and/or on EEG (8 cases) a hyper-output of concordant localization was recorded. In 5 infants who have had an electrocorticography, a concordance was obtained in all the cases except in an infant having very short crises the subtraction image did not show hyper-output. These preliminary results show that the ictal - inter-ictal SPECT subtraction images, adjusted on MRI, appears to be reliable in detecting the outset point of crises in infants and at the same time useful in guiding the positioning of intra-cranial electrodes prior to surgery intervention

  15. Evaluation of the parameters of SPECT images for yttrium-90 in radiosinoviorthesis; Avaliação dos parâmetros de aquisição de imagens SPECT para ítrio-90 em radiosinoviortese

    Energy Technology Data Exchange (ETDEWEB)

    Toledo, B.C. de; Sáa, L.V. de, E-mail: bruce.de.toledo@gmail.com [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Física Médica; Ramos, S.M.; Coelho, F.A.; Thomas, S.; Souza, S.A. de; Pinheiro, M.A. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Hospital Universitário Clementino Fraga Filho

    2017-07-01

    Introduction: the evaluation of the distribution of radioactive material in the articulation by SPECT images after radiosinoviorthesis (RSO) can guarantee the efficacy of this therapy. However, Bremsstrahlung image quality has major limitations, necessitating studies on SPECT image acquisition parameters and yttrium-90 image reconstruction methods. Methods: SPECT images were obtained from an acrylic simulator containing four cylindrical inserts to simulate capturing lesions. The images were obtained with collimators of high, medium and low (HEGP, MEGP and LEHR) energy; 130 keV power window, 70% width and 64 x 64 matrix. The reconstruction methods used were: FBP and OSEM with different filters. Results: 45 results found. The images obtained with the MEGP and HEGP collimators presented better results than those obtained with the LEHR collimator. The OSEM reconstructions were superior when the MEGP and HEGP collimators were used. Conclusions: The acquisition of yttrium-90 SPECT images with MEGP collimators showed higher sensitivity, whereas those obtained with HEPG collimators presented lower noise. The image reconstruction methods have relevant importance in the image quality, showing a significant difference between the FBP and OSEM reconstructions and between the filters used.

  16. Usefulness of semiquantitative analysis of dipyridamole-thallium-201 redistribution for improving risk stratification before vascular surgery

    International Nuclear Information System (INIS)

    Levinson, J.R.; Boucher, C.A.; Coley, C.M.; Guiney, T.E.; Strauss, H.W.; Eagle, K.A.

    1990-01-01

    Preoperative dipyridamole-thallium-201 scanning is sensitive in identifying patients prone to ischemic cardiac complications after vascular surgery, but most patients with redistribution do not have an event after surgery. Therefore, its positive predictive value is limited. To determine which patients with thallium redistribution are at highest risk, dipyridamole-thallium-201 images were interpreted semiquantitatively. Sixty-two consecutive patients with redistribution on preoperative dipyridamole-thallium-201 planar imaging studies were identified. Each thallium scan was then analyzed independently by 2 observers for the number of myocardial segments out of 15, the number of thallium views out of 3 and the number of coronary artery territories with redistribution. Seventeen patients (27%) had postoperative ischemic events, including unstable angina pectoris, ischemic pulmonary edema, myocardial infarction and cardiac death. Thallium predictors of ischemic operative complications included thallium redistribution greater than or equal to 4 myocardial segments (p = 0.03), greater than or equal to 2 of the 3 planar views (p = 0.005) and greater than or equal to 2 coronary territories (p = 0.007). No patient with redistribution in only 1 view had an ischemic event (0 of 15). Thus, determining the extent of redistribution by dipyridamole-thallium-201 scanning improves risk stratification before vascular surgery. Patients with greater numbers of myocardial segments and greater numbers of coronary territories showing thallium-201 redistribution are at higher risk for ischemic cardiac complications. In contrast, when the extent of thallium redistribution is limited, there is a lower risk despite the presence of redistribution

  17. Clinical application of cardiac SPECT

    International Nuclear Information System (INIS)

    Nishimura, Shigeyuki

    1999-01-01

    Single-photon emission computed tomography (SPECT) has replaced planar imaging techniques for myocardial scintigraphy. Thallium-201 was the dominant agent employed for myocardial perfusion imaging. Today new technetium-99m labelled radionuclides have been used as excellent alternatives to 201 Tl for detection of coronary artery disease, prognostification, and even assessment of myocardial viability. Pharmacologic stress imaging using either dipyridamole, adenosine or dobutamine is a substitute for exercise stress. Accurate determination of myocardial viability is vitally important for clinical decision making for patients with LV dysfunction who will most benefit from revascularization. Stunned and hibernated myocardium may result in profound regional LTV dysfunction in absence of necrosis. The various approach such as stress-redistribution-reinjection imaging, rest-redistribution imaging and stress-redistribution-24 hours delayed imaging has been utilized to assess myocardial viability with 201 Tl. Quantitative assessment of 99m Tc MIBI uptake reflect the degree of viability. 123 I-Metaiodobenzylguanidine (MIBG), an analog of norepinephrine, has been used for scintigraphic assessment of regional cardiac adrenergic innervation. Cardiac sympathetic denervation, assessed by 123 I-MIBG, due to ischemia in non-Q myocardial infarction and unstable angina has been shown. Quantitative cardiac MIBG scintigram was shown to have prognostic value in patients with severe congestive heart failure. 23 I-BMIPP (ρ-methyl-iodophenyl pentadecanoic acid) has been used to assess myocardial fatty acid utilization. BMIPP has the memory function of ischemia in unstable angina, since decreased BMIPP uptake persists several days after ischemic episode. Nuclear cardiology in Japan has experienced an expansion in the techniques including use of new radionuclides, 99m Tc perfusion agents, 123 I-MIBG and 23 I-BMIPP and in associated clinical application to the various cardiac diseases

  18. Thallium poisoning. Diagnosis may be elusive but alopecia is the clue.

    Science.gov (United States)

    Moore, D; House, I; Dixon, A

    1993-01-01

    Thallium is a heavy metal whose salts are used in some rodent poisons and in the manufacture of optical lenses, semiconductors, scintillation counters, low temperature thermometers, and switching devices, green coloured fireworks, and imitation jewelery, and as chemical catalysts. In clinical practice thallium isotopes are used in cardiac scanning, but the use of thallium salts to treat scalp ringworm was abandoned earlier this century because of their toxicity. The sale of thallium in Britain is strictly licensed because of its toxicity and potential for use in murder, which is helped by the fact that thallous salts are colourless, tasteless, and odorless. The more water soluble salts (such as thallium sulphate, acetate, or carbonate) have higher toxicity, and although the toxic dose is variable most deaths occur after the ingestion of 10-15 mg/kg of soluble salt. Most cases of thallium toxicity occur after oral ingestion but severe toxicity has been reported after inhalation of contaminated dust from pyrite burners, in zinc and lead smelting, and in the manufacture of cadmium, after dermal absorption through protective rubber gloves, and after snorting what was thought to be cocaine. The elimination half time of thallium is between 1.7 and 30 days depending on the time since, and chronicity of, ingestion. The elimination time phases are apparent and because of the long terminal elimination half time thallium may act as a cumulative poison. We present two cases of thallium poisoning with intent to kill. Images FIG 3 PMID:8518684

  19. Evaluation of Tourette's syndrome by 99Tcm-TRODAT-1 SPECT imaging

    International Nuclear Information System (INIS)

    Dong Feng; Liu Hong; Meng Zhaowei; Tan Jian; Zhang Benshu

    2011-01-01

    Objective: To observe dopamine transporter (DAT) binding capacity using 99 Tc m -TRODAT-1 in drug-naive patients with Tourette's syndrome (TS) on SPECT imaging, and explore possible correlations between 99 Tc m -TRODAT-1 uptake ratio and TS patient's age, disease duration, and tic severity. Methods: Eighteen drug-naive TS patients, male 14, female 4, as well as 8 age- and gender-matched healthy subjects were recruited. Brain SPECT imaging was performed 2. 5 h after intravenous injection of 11.1 - 14.8 MBq/kg 99 Tc m -TRODAT-1. ROI was drawn on the striatum including its sub-regions of caudate and putamen, with cerebellum as the background. Striatum/cerebellum ratio was calculated. Comparisons of the ratios between TS patients and controls were carried out by independent-sample t-test. Pearson correlation analysis was performed between DAT uptake ratios of striatum and patients' age, disease duration, tic severity. Results: Compared with the control, higher symmetrically striatum uptake of 99 Tc m -TRODAT-1 in TS patients was observed (2.17±0.23 vs 1.87±0.24, t=2.957, P 0.05)and tic severity(r=0.345, P>0.05) scores were not significantly correlated with specific uptake ratios measured in the striatum. But there was significant negative correlation between disease duration and the specific uptake ratios (r=-0.483, P 99 Tc m -TRODAT-1 SPECT imaging may play an adjuvant role for initial evaluation of untreated TS. (authors)

  20. Prognostic value of gated 201Tl myocardial perfusion SPECT imaging in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Li Zicheng; Chen Xiaoming; Xu Hao

    2006-01-01

    Objective: To study the prognostic value of gated 201 Tl myocardial perfusion SPECT imaging in patients with coronary artery disease and assessment of therapy strategy for the individual patient. Methods: Eighty-four patients underwent rest and exercise stress 201 Tl gated myocardial perfusion SPECT imaging and were followed up for (32.92 ± 16.77) months. Images were studied using 17 segments and 1 to 4 scoring. Global summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS=SSS-SRS) were also calculated. Post-stress and rest ejection fraction (EF) were automatically measured. Results: Nine cardiac events occurred (3.90% per year). SSS, SDS, SRS and EF were the independent predictors of cardiac events (P 201 Tl myocardial perfusion SPECT imaging can provide prognostic assessment for the patients with coronary artery disease and guide in selection of therapeutic strategy. Among all of the indices SSS is the best predictors of cardiac events. (authors)

  1. SPECT imaging of D2 dopamine receptors and endogenous dopamine release in mice

    International Nuclear Information System (INIS)

    Jongen, Cynthia; Bruin, Kora de; Booij, Jan; Beekman, Freek

    2008-01-01

    The dopamine D 2 receptor (D2R) is important in the mediation of addiction. [ 123 I]iodobenzamide (IBZM), a SPECT ligand for the D2R, has been used for in vivo studies of D2R availability in humans, monkeys, and rats. Although mouse models are important in the study of addiction, [ 123 I]IBZM has not been used in mice SPECT studies. This study evaluates the use of [ 123 I]IBZM for measuring D2R availability in mice. Pharmacokinetics of [ 123 I]IBZM in mice were studied with pinhole SPECT imaging after intravenous (i.v.) injection of [ 123 I]IBZM (20, 40, and 70 MBq). In addition, the ability to measure the release of endogenous dopamine after amphetamine administration with [ 123 I]IBZM SPECT was investigated. Thirdly, i.v. administration, the standard route of administration, and intraperitoneal (i.p.) administration of [ 123 I]IBZM were compared. Specific binding of [ 123 I]IBZM within the mouse striatum could be clearly visualized with SPECT. Peak specific striatal binding ratios were reached around 90 min post-injection. After amphetamine administration, the specific binding ratios of [ 123 I]IBZM decreased significantly (-27.2%; n=6; p=0.046). Intravenous administration of [ 123 I]IBZM led to significantly higher specific binding than i.p. administration of the same dose. However, we found that i.v. administration of a dose of 70 MBq [ 123 I]IBZM might result in acute ethanol intoxication because ethanol is used as a preparative aid for the routine production of [ 123 I]IBZM. Imaging of D2R availability and endogenous dopamine release in mice is feasible using [ 123 I]IBZM single pinhole SPECT. Using commercially produced [ 123 I]IBZM, a dose of 40 MBq injected i.v. can be recommended. (orig.)

  2. A parallel Monte Carlo code for planar and SPECT imaging: implementation, verification and applications in (131)I SPECT.

    Science.gov (United States)

    Dewaraja, Yuni K; Ljungberg, Michael; Majumdar, Amitava; Bose, Abhijit; Koral, Kenneth F

    2002-02-01

    This paper reports the implementation of the SIMIND Monte Carlo code on an IBM SP2 distributed memory parallel computer. Basic aspects of running Monte Carlo particle transport calculations on parallel architectures are described. Our parallelization is based on equally partitioning photons among the processors and uses the Message Passing Interface (MPI) library for interprocessor communication and the Scalable Parallel Random Number Generator (SPRNG) to generate uncorrelated random number streams. These parallelization techniques are also applicable to other distributed memory architectures. A linear increase in computing speed with the number of processors is demonstrated for up to 32 processors. This speed-up is especially significant in Single Photon Emission Computed Tomography (SPECT) simulations involving higher energy photon emitters, where explicit modeling of the phantom and collimator is required. For (131)I, the accuracy of the parallel code is demonstrated by comparing simulated and experimental SPECT images from a heart/thorax phantom. Clinically realistic SPECT simulations using the voxel-man phantom are carried out to assess scatter and attenuation correction.

  3. Economic and biological costs of cardiac imaging

    Directory of Open Access Journals (Sweden)

    Picano Eugenio

    2005-05-01

    Full Text Available Abstract Medical imaging market consists of several billion tests per year worldwide. Out of these, at least one third are cardiovascular procedures. Keeping in mind that each test represents a cost, often a risk, and a diagnostic hypothesis, we can agree that every unnecessary and unjustifiable test is one test too many. Small individual costs, risks, and wastes multiplied by billions of examinations per year represent an important population, society and environmental burden. Unfortunately, the appropriateness of cardiac imaging is extra-ordinarily low and there is little awareness in patients and physicians of differential costs, radiological doses, and long term risks of different imaging modalities. For a resting cardiac imaging test, being the average cost (not charges of an echocardiogram equal to 1 (as a cost comparator, the cost of a CT is 3.1x, of a SPECT 3.27x, of a Cardiovascular Magnetic Resonance imaging 5.51x, of a PET 14.03x, and of a right and left heart catheterization 19.96x. For stress cardiac imaging, compared with the treadmill exercise test equal to 1 (as a cost comparator, the cost of stress echocardiography is 2.1x and of a stress SPECT scintigraphy is 5.7x. Biohazards and downstream long-term costs linked to radiation-induced oncogenesis should also be considered. The radiation exposure is absent in echo and magnetic resonance, and corresponds to 500 chest x rays for a sestamibi cardiac stress scan and to 1150 chest x rays for a thallium scan. The corresponding extra-risk in a lifetime of fatal cancer is 1 in 2000 exposed patients for a sestamibi stress and 1 in 1000 for a thallium scan. Increased awareness of economic, biologic, and environmental costs of cardiac imaging will hopefully lead to greater appropriateness, wisdom and prudence from both the prescriber and the practitioner. In this way, the sustainability of cardiac imaging will eventually improve.

  4. Image viewing station for MR and SPECT : using personal computer

    International Nuclear Information System (INIS)

    Yim, Byung Il; Jeong, Eun Kee; Suh, Jin Suck; Kim, Myeong Joon

    1996-01-01

    Macro language was programmed to analyze and process on Macintosh personal computers, GEMR images digitally transferred from the MR main computer, with special interest in the interpretation of information such as patients data and imaging parameters under each image header. By this method, raw data(files) of certain patients may be digitally stored on a hard disk or CD ROM, and the quantitative analysis, interpretation and display is possible. Patients and images were randomly selected 4.X MR images were transferred through FTP using the ethernet network. 5.X and SPECT images were transferred using floppy diskettes. To process transferred images, an freely distributed software for Macintosh namely NIH Image, with its macro language, was used to import images and translate header information. To identify necessary information, a separate window named I nfo=txt , was made for each image series. MacLC, Centris650, and PowerMac6100/CD, 7100/CD, 8100/CD models with 256 color and RAM over 8Mbyte were used. Different versions of MR images and SPECT images were displayed simultaneously and a separate window named 'info-txt' was used to show all necessary information(name of the patient, unit number, date, TR, TE, FOV etc.). Additional information(diagnosis, pathologic report etc.) was stored in another text box in 'info-txt'. The size of the file for each image plane was about 149Kbytes and the images were stored in a step-like file folders. 4.X and 5.X GE Signa 1.5T images were successfully processed with Macintosh computer and NIH Image. This result may be applied to many fields and there is hope of a broader area of application with the linkage of NIH Image and a database program

  5. Slow late myocardial clearance of thallium: a characteristic phenomenon in coronary artery disease

    International Nuclear Information System (INIS)

    Sklar, J.; Kirch, D.; Johnson, T.; Hasegawa, B.; Peck, S.; Steele, P.

    1982-01-01

    Researchers extended the quantitative seven-pinhole method to follow the dynamics of thallium redistribution after exercise. Researchers observed a pattern of slow late thallium clearance that appears to be characteristic of myocardium supplied by obstructed coronary arteries. In 28 subjects, quantitative thallium scintigrams and blood samples for thallium concentration were taken immediately, 2 hours and 4 hours after maximal treadmill exercise. Twenty subjects had coronary artery disease (CAD) and eight were normal. The rate of thallium clearance from the blood (TCB) was compared with the rate of thallium clearance from each segmental region of myocardium between the 2- and 4-hour images. In seven of the eight normal subjects, TCM exceeded TCB in all regions of all images. Seventeen of the 20 CAD patients had at least one region where TCM was less than TCB. Of the 13 patients with multivessel CAD 11 had multiple regions with TCM less than TCB. Using this criterion, we detected 31 of 39 obstructed coronary arteries. Of the 37 regions that were abnormal by this analysis, 30 corresponded to obstructed coronary arteries. In contrast, while conventional circumferential count profile analysis also was abnormal in 17 of the 20 CAD patients, it diagnosed multivessel CAD in only five of the 13 patients that had it. These results show that slow late thallium clearance from myocardium is characteristic of regions of myocardium supplied by diseased coronary arteries and that observation of this phenomenon may improve diagnostic sensitivity for the presence of multivessel CAD

  6. Simultaneous reconstruction and segmentation for dynamic SPECT imaging

    International Nuclear Information System (INIS)

    Burger, Martin; Rossmanith, Carolin; Zhang, Xiaoqun

    2016-01-01

    This work deals with the reconstruction of dynamic images that incorporate characteristic dynamics in certain subregions, as arising for the kinetics of many tracers in emission tomography (SPECT, PET). We make use of a basis function approach for the unknown tracer concentration by assuming that the region of interest can be divided into subregions with spatially constant concentration curves. Applying a regularised variational framework reminiscent of the Chan-Vese model for image segmentation we simultaneously reconstruct both the labelling functions of the subregions as well as the subconcentrations within each region. Our particular focus is on applications in SPECT with the Poisson noise model, resulting in a Kullback–Leibler data fidelity in the variational approach. We present a detailed analysis of the proposed variational model and prove existence of minimisers as well as error estimates. The latter apply to a more general class of problems and generalise existing results in literature since we deal with a nonlinear forward operator and a nonquadratic data fidelity. A computational algorithm based on alternating minimisation and splitting techniques is developed for the solution of the problem and tested on appropriately designed synthetic data sets. For those we compare the results to those of standard EM reconstructions and investigate the effects of Poisson noise in the data. (paper)

  7. Response analysis for an approximate 3-D image reconstruction in cone-beam SPECT

    International Nuclear Information System (INIS)

    Murayama, Hideo; Nohara, Norimasa

    1991-01-01

    Cone-beam single photon emission computed tomography (SPECT) offers the potential for a large increase in sensitivity as compared with parallel hole or fan-beam collimation. Three-dimensional image reconstruction was approximately accomplished by backprojecting filtered projections using a two-dimensional fan-beam algorithm. The cone-beam projection data were formed from mathematical phantoms as analytically derived line integrals of the density. In order to reduce the processing time, the filtered projections were backprojected into each plane parallel to the circle on which the focal point moved. Discrepancy of source position and degradation of resolution were investigated by computer simulation in three-dimensional image space. The results obtained suggest that, the nearer to the central plane or the axis of rotation, the less image degradation is performed. By introducing a parameter of angular difference between the focal point and a fixed point in the image space during rotation, degradation of the reconstructed image can be estimated for any cone-beam SPECT system. (author)

  8. Analysis of CT and PET/SPECT images for dosimetry calculation

    International Nuclear Information System (INIS)

    Massicano, Felipe; Massicano, Adriana V.F.; Silva, Natanael Gomes da; Cintra, Felipe Belonsi; Yoriyaz, Helio; Carvalho, Rodrigo Mueller de

    2009-01-01

    Computer images are routinely used in diagnostic centers and hospitals. In particular in the field of Nuclear Medicine they help in the diagnosis and planning therapy against cancer. In the case of the planning therapy the quantifying the distribution of dose in patients is very important, because it provides an estimate of the dose in the tumor and healthy tissues, allowing a greater understanding on the response and toxicity caused by this dose. The aim of this study is to analyze both kinds of images: CT and PET/SPECT and their potential utilization for dosimetry calculation. PET or SPECT images were analyzed using a Gamma Camera, brand Medis, model Nuclide-TH/22 through image acquisition of scanned phantoms containing a known activity inside their volume so that a relationship between the number of counts for each voxel in the image and the real activity will be constructed. The heterogeneous organism patient's is specified from the computed tomography (CT) through number of Hounsfield. However, there is not a simple correlation to convert Hounsfield numbers into material tissues, therefore, in this work we developed a software in Java to convert Hounsfield numbers in mass density. Moreover, the software provides a map of tissues and a text file containing the elemental weights to be used by the Monte Carlo transport code MCNP5 to perform dose calculations. (author)

  9. Multi-pinhole collimator design for small-object imaging with SiliSPECT: a high-resolution SPECT

    International Nuclear Information System (INIS)

    Shokouhi, S; Peterson, T E; Metzler, S D; Wilson, D W

    2009-01-01

    We have designed a multi-pinhole collimator for a dual-headed, stationary SPECT system that incorporates high-resolution silicon double-sided strip detectors. The compact camera design of our system enables imaging at source-collimator distances between 20 and 30 mm. Our analytical calculations show that using knife-edge pinholes with small-opening angles or cylindrically shaped pinholes in a focused, multi-pinhole configuration in combination with this camera geometry can generate narrow sensitivity profiles across the field of view that can be useful for imaging small objects at high sensitivity and resolution. The current prototype system uses two collimators each containing 127 cylindrically shaped pinholes that are focused toward a target volume. Our goal is imaging objects such as a mouse brain, which could find potential applications in molecular imaging.

  10. Software-based hybrid perfusion SPECT/CT provides diagnostic accuracy when other pulmonary embolism imaging is indeterminate

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Nishant; Xie, Karen; Mar, Winnie; Anderson, Thomas M.; Carney, Benjamin; Mehta, Nikhil; Machado, Roberto; Blend, Michael J.; Lu, Yang [University of Illinois Hospital and Health Sciences System, Chicago (Korea, Republic of)

    2015-12-15

    To investigate the diagnostic performance of perfusion single-photon emission computed tomography/computed tomography (Q-SPECT/CT) in patients suspected to have pulmonary embolism (PE) but with indeterminate computed tomographic pulmonary angiography (CTPA) or planar ventilation/perfusion (V/Q) scans. This retrospective study included two groups of patients. Group I consisted of 49 patients with nondiagnostic CTPA. These 49 patients underwent subsequent V/Q scans. Further Q-SPECTs were obtained in patients with indeterminate planar images and fused with existing CTPA. Group II consisted of 182 non-CTPA patients with indeterminate V/Q scans. These 182 patients underwent further Q-SPECT and separate noncontrast low-dose CT chest. Fusion Q-SPECT/CT scans were obtained through FDA-approved software and interpreted according to published criteria as positive, negative, or indeterminate for PE. Upon retrospective analyses, the final diagnosis was made using composite reference standards including all available clinical and imaging information for at least 6-month follow-up. In group I patients, 1 was positive, 24 were negative, and another 24 (49 %, 24/49) were indeterminate. In the subsequent 24 Q-SPECT/CTPAs, 4 were positive, 19 were negative, and 1 was indeterminate (4.2 %, 1/24). In group II patients, 9 (4.9 %, 9/182) were indeterminate, 33 were positive, and 140 were negative. The combined nondiagnostic rate for Q-SPECT/CT was only 4.9 % (10/206). There was six false-negative and one false-positive Q-SPECT/CT examinations. The sensitivity, specificity, and positive and negative predictive value of Q-SPECT/CT were 85.7 % (36/42), 99.4 % (153/154), 97.3 % (36/37) and 96.2 % (153/159), respectively. Q-SPECT/CT improves the diagnostic rate with promising accuracy in diagnosing PE that yields a satisfactory clinical verdict, especially when the CTPA and planar V/Q scan are indeterminate.

  11. Effects of attenuation map accuracy on attenuation-corrected micro-SPECT images

    NARCIS (Netherlands)

    Wu, C.; Gratama van Andel, H.A.; Laverman, P.; Boerman, O.C.; Beekman, F.J.

    2013-01-01

    Background In single-photon emission computed tomography (SPECT), attenuation of photon flux in tissue affects quantitative accuracy of reconstructed images. Attenuation maps derived from X-ray computed tomography (CT) can be employed for attenuation correction. The attenuation coefficients as well

  12. Clinical features and {sup 123}I-FP-CIT SPECT imaging in drug-induced parkinsonism and Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Diaz-Corrales, Francisco J.; Escobar-Delgado, Teresa [Hospital Universitario Virgen del Rocio/CSIC/Universidad de Sevilla, Unidad de Trastornos del Movimiento, Servicio de Neurologia, Instituto de Biomedicina de Sevilla, Seville (Spain); Sanz-Viedma, Salome [Hospital Universitario Virgen del Rocio, Unidad Diagnostica de Medicina Nuclear, Seville (Spain); Garcia-Solis, David [Hospital Universitario Virgen del Rocio, Unidad Diagnostica de Medicina Nuclear, Seville (Spain); Centro de Investigacion Biomedica en Red sobre Enfermedades Neurodegenerativas (CIBERNED), Seville (Spain); Mir, Pablo [Hospital Universitario Virgen del Rocio/CSIC/Universidad de Sevilla, Unidad de Trastornos del Movimiento, Servicio de Neurologia, Instituto de Biomedicina de Sevilla, Seville (Spain); Centro de Investigacion Biomedica en Red sobre Enfermedades Neurodegenerativas (CIBERNED), Seville (Spain); Hospital Universitario Virgen del Rocio, Unidad de Trastornos del Movimiento. Servicio de Neurologia, Seville (Spain)

    2010-03-15

    To determine clinical predictors and accuracy of {sup 123}I-FP-CIT SPECT imaging in the differentiation of drug-induced parkinsonism (DIP) and Parkinson's disease (PD). Several clinical features and {sup 123}I-FP-CIT SPECT images in 32 patients with DIP, 25 patients with PD unmasked by antidopaminergic drugs (PDu) and 22 patients with PD without a previous history of antidopaminergic treatment (PDc) were retrospectively evaluated. DIP and PD shared all clinical features except symmetry of parkinsonian signs which was more frequently observed in patients with DIP (46.9%) than in patients with PDu (16.0%, p<0.05) or PDc (4.5%, p<0.01). Qualitatively {sup 123}I-FP-CIT SPECT images were normal in 29 patients with DIP (90.6%) and abnormal in all patients with PD, and this imaging technique showed high levels of accuracy. DIP and PD are difficult to differentiate based on clinical signs. The precision of clinical diagnosis could be reliably enhanced by {sup 123}I-FP-CIT SPECT imaging. (orig.)

  13. Quantitative assessment of thallium myocardial washout rate: Importance of peak heart rate and lung thallium uptake in defining normal values

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Kozuka, Takahiro; Saito, Muneyasu; Sumiyoshi, Tetsuya; National Cardiovascular Center, Suita, Osaka

    1987-01-01

    Traditionally, the results of exercise thallium scintigraphy were interpreted by transient defect analysis using initial and delayed images. Recently, washout rate analysis has been used for the relative quantification of exercise thallium scintigraphy. A diffuse slow washout from all myocardial regions has been defined as the indicator of extensive coronary artery disease. However, slow washout has occasionally been observed in normal cases and in healthy myocardial segments which are not supplied by a stenosed artery in patients with single or double vessel disease. We evaluate the factors influencing washout rate in 100 normal patients and 63 patients with angina pectoris (33 cases of single vessel disease and 30 cases of double vessel disease). The washout rates were calculated using circumferential profile analysis. In normal patients, washout rate was closely related to peak heart rate (r=0.72) and inversely related to lung thallium uptake (r=-0.56). A diffuse slow washout was observed in seven (7%) of 100 normal patients, six (18%) of 33 cases of single vessel disease and eight (24%) of 30 cases of double vessel disease. The patients with diffuse slow washout showed significantly higher lung thallium uptake values and lower peak heart rates than those without diffuse slow washout (P<0.01). Thus, this false positive slow washout should be considered in the interpretation of quantitative exercise thallium scintigraphy. (orig.)

  14. Imaging of D2 dopamine receptors of patients with Parkinson's disease using SPECT and 131I-IBZM

    International Nuclear Information System (INIS)

    Zhang Wei; Wang Jian; Jiang Yuping; Lu Chuanzhen

    2001-01-01

    Objective: To evaluate the usefulness of SPECT with 131 I-IBZM in imaging of D 2 Dopamine receptors in patients with Parkinson's disease (PD). Methods: Six patients which early unmedicated PD, six patients with moderate or advanced PD treated with long-term oral L-Dopa and Four control subjects were investigated with SPECT using 131 I-IBZM as dopamine receptor ligand. The ratio of basal ganglia to occipital cortex (BG/OC) and ratio of basal ganglia to frontal cortex (BG/FC) were calculated as semiquantitative parameter of striatal D 2 dopamine receptor's function. Results: The SPECT images revealed high uptake of IBZM in the basal ganglia. In the early unmedicated PD group, the BG/PC and BG/FC rates were significantly higher in the striatum contralateral to the parkinsonism. In the moderate or advanced PD group, no significant differences were observed bilaterally, and the BG/OC and the BG/FC rates in this group was lower than those of the control. Conclusion: 131 I-IBZM with SPECT imaging is useful in evaluating patients with Parkinson's disease

  15. Prognostic value of exercise thallium-201 imaging in patients presenting for evaluation of chest pain

    International Nuclear Information System (INIS)

    Brown, K.A.; Boucher, C.A.; Okada, R.D.; Guiney, T.E.; Newell, J.B.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Accurate prognostic information is important in determining optimal management of patients presenting for evaluation of chest pain. In this study, the ability of exercise thallium-201 myocardial imaging to predict future cardiac events (cardiovascular death or nonfatal myocardial infarction) was correlated with clinical, coronary and left ventricular angiographic and exercise electrocardiographic data in 139 consecutive, nonsurgically managed patients followed-up over a 3 to 5 year period (mean follow-up, 3.7 +/- 0.9), using a logistic regression analysis. Among patients without prior myocardial infarction (100 of 139), the number of myocardial segments with transient thallium-201 defects was the only statistically significant predictor of future cardiac events when all patient variables were evaluated. Among patients with myocardial infarction before evaluation (39 of 139), angiographic ejection fraction was the only significant predictor of future cardiac events when all variables were considered. This study suggests an approach to evaluate the risk of future cardiac events in patients with possible ischemic heart disease

  16. The assessment of whole body bone SPECT in oncology

    International Nuclear Information System (INIS)

    Scortechini, Shonika

    2009-01-01

    Full text: Objectives: To assess the significance and practicability of oncology whole body bone SPECT as part of the standard skeletal survey and its impact on the traditional planar whole body bone imaging protocol. Method: Three consenting oncology patients were injected with a standard adult dose of Tc-99m MOP. Delayed Imaging of whole body sweep and SPECT acquisitions were performed on a Siemens Symbia T6. The patient was positioned supine with arms down with a SPECT scan length covering vortex to thighs. SPECT data was reconstructed and a single whole body zipped file created. Normal SPECT slices along with a cine/MIP of the zipped data were created for review. Results: Both image data sets were reviewed to assess if SPECT provided any further diagnostic clinical information not apparent in planer imaging. In our limited review, whole body SPECT did not add extra value to the planar whole body scans performed; it did however demonstrate vertebral involvement with greater resolution. The processing software and system limitations in seamlessly knitting data sets (creating image artefacts) was a major limiting factor in not pursuing further studies. Conclusion: Both imaging techniques offer differing advantages and limitations, however due to image artefact in the triple knitted SPECT approach with current software technology, it cannot be substituted for whole body imaging at this time.

  17. Normal anatomy of lung perfusion SPECT scintigraphy

    International Nuclear Information System (INIS)

    Moskowitz, G.W.; Levy, L.M.

    1987-01-01

    Ten patients studies for possible pulmonary embolic disease had normal lung perfusion planar and SPECT scintigraphy. A computer program was developed to superimpose the CT scans on corresponding SPECT images. Superimposition of CT scans on corresponding SPECT transaxial cross-sectional images, when available, provides the needed definition and relationships of adjacent organs. SPECT transaxial sections provide clear anatomic definition of perfusion defects without foreground and background lung tissue superimposed. The location, shape, and size of the perfusion defects can be readily assessed by SPECT. An algorithm was developed for the differentiation of abnormal pulmonary perfusion patterns from normal structures on variation

  18. Practical reconstruction protocol for quantitative 90Y bremsstrahlung SPECT/CT

    International Nuclear Information System (INIS)

    Siman, W.; Mikell, J. K.; Kappadath, S. C.

    2016-01-01

    Purpose: To develop a practical background compensation (BC) technique to improve quantitative 90 Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. Methods: All images were acquired using medium-energy collimation in six energy windows (EWs), ranging from 70 to 410 keV. The EWs were determined based on the signal-to-background ratio in planar images of an acrylic phantom of different thicknesses (2–16 cm) positioned below a 90 Y source and set at different distances (15–35 cm) from a gamma camera. The authors adapted the widely used EW-based scatter-correction technique by modeling the BC as scaled images. The BC EW was determined empirically in SPECT/CT studies using an IEC phantom based on the sphere activity recovery and residual activity in the cold lung insert. The scaling factor was calculated from 20 clinical planar 90 Y images. Reconstruction parameters were optimized in the same SPECT images for improved image quantification and contrast. A count-to-activity calibration factor was calculated from 30 clinical 90 Y images. Results: The authors found that the most appropriate imaging EW range was 90–125 keV. BC was modeled as 0.53× images in the EW of 310–410 keV. The background-compensated clinical images had higher image contrast than uncompensated images. The maximum deviation of their SPECT calibration in clinical studies was lowest (<10%) for SPECT with attenuation correction (AC) and SPECT with AC + BC. Using the proposed SPECT-with-AC + BC reconstruction protocol, the authors found that the recovery coefficient of a 37-mm sphere (in a 10-mm volume of interest) increased from 39% to 90% and that the residual activity in the lung insert decreased from 44% to 14% over that of SPECT images with AC alone. Conclusions: The proposed EW-based BC model was developed for 90 Y bremsstrahlung imaging. SPECT with AC + BC gave improved lesion detectability and activity

  19. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    International Nuclear Information System (INIS)

    Suga, K.; Yasuhiko, K.; Iwanaga, H.; Tokuda, O.; Matsunaga, N.

    2009-01-01

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  20. Functional Mechanism of Lung Mosaic CT Attenuation: Assessment with Deep-Inspiration Breath-Hold Perfusion SPECT-CT Fusion Imaging and Non-Breath-Hold Technegas SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Suga, K.; Yasuhiko, K. (Dept. of Radiology, St. Hill Hospital, Ube, Yamaguchi (Japan)); Iwanaga, H.; Tokuda, O.; Matsunaga, N. (Dept. of Radiology, Yamaguchi Univ. School of Medicine, Ube, Yamaguchi (Japan))

    2009-01-15

    Background: The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. Purpose: To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Material and Methods: Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. Results: On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Conclusion: Although further validation is

  1. Functional mechanism of lung mosaic CT attenuation: assessment with deep-inspiration breath-hold perfusion SPECT-CT fusion imaging and non-breath-hold Technegas SPECT.

    Science.gov (United States)

    Suga, K; Yasuhiko, K; Iwanaga, H; Tokuda, O; Matsunaga, N

    2009-01-01

    The functional mechanism of lung mosaic computed tomography attenuation (MCA) in pulmonary vascular disease (PVD) and obstructive airway disease (OAD) has not yet been fully clarified. To clarify the mechanism of MCA in these diseases by assessing the relationship between regional lung function and CT attenuation change at MCA sites with the use of automated deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images and non-breath-hold Technegas SPECT. Subjects were 42 PVD patients (31 pulmonary thromboembolism, four primary/two secondary pulmonary hypertension, and five Takayasu arteritis), 12 OAD patients (five acute asthma, four obliterative bronchiolitis, and three bronchiectasis), and 12 normal controls, all of whom had MCA on DIBrH CT. The relationship between regional lung function and CT attenuation change at the lung slices with MCA was assessed using DIBrH perfusion SPECT-CT fusion images and non-breath-hold Technegas SPECT. The severity of perfusion defects with or without MCA was quantified by regions-of-interest analysis. On DIBrH CT and perfusion SPECT, in contrast to no noticeable CT attenuation abnormality and fairly uniform perfusion in controls, 60 MCA and 274 perfusion defects in PVD patients, and 18 MCA and 61 defects in OAD patients were identified, with a total of 77 ventilation defects on Technegas SPECT in all patients. SPECT-CT correlation showed that, throughout the 78 MCA sites of all patients, lung perfusion was persistently decreased at low CT attenuation and preserved at intervening high CT attenuation, while lung ventilation was poorly correlated with CT attenuation change. The radioactivity ratios of reduced perfusion and the intervening preserved perfusion at the 78 perfusion defects with MCA were significantly lower than those at the remaining 257 defects without MCA (P<0.0001). Although further validation is required, our results indicate that heterogeneous pulmonary arterial

  2. The clinical role of thallium-201 scintigraphy in the management and prognosis of coronary artery disease

    International Nuclear Information System (INIS)

    Gammage, M.D.; Murray, D.P.; Rafiqi, E.; Murray, R.G.

    1984-01-01

    To determine the clinical impact of thallium-201 scintigraphy in coronary artery disease, the indications, diagnostic yield and contribution to patient management were reviewed retrospectively in 103 patients referred for routine investigations. Exercise and redistribution image data were collected in multiple projections and interpreted by visual and semi-quantitative means. A segmental image defect was accepted as indicating the presence of coronary artery disease. Thallium-201 scintigraphy was performed as a diagnostic procedure in 71 patients (69%) who had equivocal evidence of coronary artery disease. In 57 (80%) of these patients, thallium-201 scintigraphy was normal and 53 (75%) were spared diagnostic coronary arteriography. Despite normal thallium-201 scintigrams, arteriography was performed in 4 patients with persisting symptoms and demonstrated normal vessels in 2 patients and single vessel disease in 2 patients. Conversely, arteriography was normal in 2 of 14 patients (14%) with unequivocal image defects. Thallium-201 scintigraphy was performed as a functional complement to coronary arteriography in 32 patients, influencing the decision for coronary surgery in 10, for angioplasty in 4 and against surgery in 2. Myocardial ischaemia was confirmed in 8 and refuted in 8 patients with questionable arteriographic coronary disease. Positive management decisions were taken as a result of thallium-201 scintigraphy in 80 of these 103 patients (78%). These data confirm the vital role of thallium-201 scintigraphy in the evaluation and management of patients with suspected and proven coronary artery disease. (orig.)

  3. Feasibility of a CdTe-based SPECT for high-resolution low-dose small animal imaging: a Monte Carlo simulation study

    International Nuclear Information System (INIS)

    Park, S-J; Yu, A R; Lee, Y-J; Kim, Y-S; Kim, H-J

    2014-01-01

    Dedicated single-photon-emission computed tomography (SPECT) systems based on pixelated semiconductors such as cadmium telluride (CdTe) are in development to study small animal models of human disease. In an effort to develop a high-resolution, low-dose system for small animal imaging, we compared a CdTe-based SPECT system and a conventional NaI(Tl)-based SPECT system in terms of spatial resolution, sensitivity, contrast, and contrast-to-noise ratio (CNR). In addition, we investigated the radiation absorbed dose and calculated a figure of merit (FOM) for both SPECT systems. Using the conventional NaI(Tl)-based SPECT system, we achieved a spatial resolution of 1.66 mm at a 30 mm source-to-collimator distance, and a resolution of 2.4-mm hot-rods. Using the newly-developed CdTe-based SPECT system, we achieved a spatial resolution of 1.32 mm FWHM at a 30 mm source-to-collimator distance, and a resolution of 1.7-mm hot-rods. The sensitivities at a 30 mm source-to-collimator distance were 115.73 counts/sec/MBq and 83.38 counts/sec/MBq for the CdTe-based SPECT and conventional NaI(Tl)-based SPECT systems, respectively. To compare quantitative measurements in the mouse brain, we calculated the CNR for images from both systems. The CNR from the CdTe-based SPECT system was 4.41, while that from the conventional NaI(Tl)-based SPECT system was 3.11 when the injected striatal dose was 160 Bq/voxel. The CNR increased as a function of injected dose in both systems. The FOM of the CdTe-based SPECT system was superior to that of the conventional NaI(Tl)-based SPECT system, and the highest FOM was achieved with the CdTe-based SPECT at a dose of 40 Bq/voxel injected into the striatum. Thus, a CdTe-based SPECT system showed significant improvement in performance compared with a conventional system in terms of spatial resolution, sensitivity, and CNR, while reducing the radiation dose to the small animal subject. Herein, we discuss the feasibility of a CdTe-based SPECT system for high

  4. Assessment of left ventricular performance by ECG-gated SPECT. Comparison with magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tadamura, Eiji; Inubushi, Masayuki; Kubo, Shigeto; Matsumoto, Keiichi; Yokoyama, Hiroshi; Fujita, Toru; Konishi, Junji [Kyoto Univ. (Japan). Faculty of Medicine

    1999-10-01

    In the measurement of a left ventricular volume, MIBI-QGS was compared with MRI. Because it became clear by the experiment using phantom that a volume calculated with QGS was smaller than the actual volume, data of clinical study were corrected. Subjects were 20 patients with coronary artery disease. Fourteen patients had anamnesis of myocardial infarct. ECG-gated SPECT was performed one hour after intravenous injection of MIBI (600 MBq) in rest. End diastolic volume (EDV), end systolic volume (ESV) and ejection fraction (EF) were calculated using QGS. Cine-MR image was obtained by using MR system of 1.5 Tesla within 1 week after SPECT. A condition was as follows; segmented k-space gradient echo with view sharing, TR=11 ms, TE=1.4 ms, flip angle 20 degree, field of view 32 cm, matrix 256 x 196, 8 lines per segment. LVEF, ESV and EF were analysed by Bland-Altman method, and the difference between MIBI-gated-SPECT and MRI was no problem. Horizontal dislocation image and vertical major axis dislocation image were provided. Minor axis crossing images of 10-12 slice were also filmed in order to cover all left ventricles. As a result, availability of MIBI-QGS became clear. Some factors which produces the measurement error are examined. (K.H.)

  5. Quantitative assessment of 201TlCl myocardial SPECT

    International Nuclear Information System (INIS)

    Uehara, Toshiisa

    1987-01-01

    Clinical evaluation of the quantitative analysis of Tl-201 myocardial tomography by SPECT (Single Photon Emission Computed Tomography) was performed in comparison with visual evaluation. The method of quantitative analysis has been already reported in our previous paper. In this study, the program of re-standardization in the case of lateral myocardial infarction was added. This program was useful mainly for the evaluation of lesions in the left circumflex coronary artery. Regarding the degree of diagnostic accuracy of myocardial infarction in general, quantitative evaluation of myocardial SPECT images was highest followed by visual evaluation of myocardial SPECT images, and visual evaluation of myocardial planar images. However, in the case of anterior myocardial infarction, visual evaluation of myocardial SPECT images has almost the same detectability as quantitative evaluation of myocardial SPECT images. In the case of infero-posterior myocardial infarction, quantitative evaluation was superior to visual evaluation. As for specificity, quantitative evaluation of SPECT images was slightly inferior to visual evaluation of SPECT images. An infarction map was made by quantitative analysis and this enabled us to determine the infarction site, extent and degree according to easily recognizable patterns. As a result, the responsible coronary artery lesion could be inferred correctly and the calculated infarction score could be correlated with the residual left ventricular function after myocardial infarction. (author)

  6. Unsuspected Widespread Cardiac Sarcoma in a Child

    OpenAIRE

    Spieth, Michael E.; Kasner, Darcy I.; Prasannan, Latha

    2003-01-01

    The case of a patient with an undifferentiated metastatic cardiac sarcoma is presented. A thallium-201 tumor study was performed to evaluate lung nodules. Thallium-201 chloride was injected intravenously and whole body images, as well as single photon emission computer tomography (SPECT) imaging of the chest, were obtained and reconstructed. They were displayed in three planes and then reconstructed again in cardiac planes. Multiple unsuspected metastases were found in the lower extremities. ...

  7. Evaluating microvascular obstruction after acute myocardial infarction using cardiac magnetic resonance imaging and 201-thallium and 99m-technetium pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Onishi, Takayuki; Kobayashi, Isshi; Onishi, Yuko; Kawashima, Tomoyuki; Muramoto, Hirotaka; Nakamura, Hiroaki; Nagata, Yasutoshi; Umezawa, Shigeo; Niwa, Akihiro

    2010-01-01

    Few studies have compared the ability of cardiac magnetic resonance (CMR) with that of scintigraphy using 201-thallium (201-Tl) and 99m-technetium pyrophosphate (99m-Tc PYP) to evaluate microvascular obstructions (MOs). In the present study the relationship between the scintigraphic and CMR characteristics of MOs after acute myocardial infarction (MI) was examined. The 14 patients (age 69±8 years, 11 males) underwent 201-Tl/99m-Tc PYP single photon emission computed tomography (SPECT) 7±3 days, initial CMR 16±12 days, and follow-up CMR 193±20 days after a reperfused first acute MI. Each image was analyzed using a 17-segment model. Segmental extent of delayed enhancement (DE), wall motion (WM) and degree of 201-Tl uptake were scored in 238 segments. Of 91 MI segments, MO was recognized in 22 (25%) segments on CMR. WM was significantly better in proportion to 201-Tl uptake (P=0.01) in MO segments. All 8 MO segments with WM improvement at follow-up had 99m-Tc PYP uptake, although only 3 (21%) of 14 MO segments that did not show WM improvement at follow-up had 99m-Tc PYP uptake (P=0.001). 99m-Tc PYP and 201-Tl scintigraphy have the potential to predict WM status and improvement of the MO region after reperfused acute MI. (author)

  8. Radionuclide cisternography: SPECT and 3D-rendering. Radionuklidzisternographie: SPECT- und 3D-Technik

    Energy Technology Data Exchange (ETDEWEB)

    Henkes, H; Huber, G; Piepgras, U [Universitaet des Saarlandes, Homburg/Saar (Germany, F.R.). Abt. fuer Neuroradiologie; Hierholzer, J [Freie Univ. Berlin (Germany, F.R.). Strahlenklinik und Poliklinik; Cordes, M [British Columbia Univ., Vancouver, BC (Canada). Belzberg Lab. of Neuroscience

    1991-10-01

    Radionuclide cisternography is indicated in the clinical work-up for hydrocephalus, when searching for CSF leaks, and when testing whether or not intracranial cystic lesions are communicating with the adjacent subarachnoid space. This paper demonstrates the feasibility and diagnostic value of SPECT and subsequent 3D surface rendering in addition to conventional rectilinear CSF imaging in eight patients. Planar images allowed the evaluation of CSF circulation and the detection of CSF fistula. They were advantageous in examinations 48 h after application of {sup 111}In-DTPA. SPECT scans, generated 4-24 h after tracer application, were superior in the delineation of basal cisterns, especially in early scans; this was helpful in patients with pooling due to CSF fistula and in cystic lesions near the skull base. A major drawback was the limited image quality of delayed scans, when the SPECT data were degraded by a low count rate. 3D surface rendering was easily feasible from SPECT data and yielded high quality images. The presentation of the spatial distribution of nuclide-contaminated CSF proved especially helpful in the area of the basal cisterns. (orig.).

  9. Disappearance of myocardial perfusion defects on prone SPECT imaging: Comparison with cardiac magnetic resonance imaging in patients without established coronary artery disease

    Directory of Open Access Journals (Sweden)

    Hedén Bo

    2009-08-01

    Full Text Available Abstract Background It is of great clinical importance to exclude myocardial infarction in patients with suspected coronary artery disease who do not have stress-induced ischemia. The diagnostic use of myocardial perfusion single-photon emission computed tomography (SPECT in this situation is sometimes complicated by attenuation artifacts that mimic myocardial infarction. Imaging in the prone position has been suggested as a method to overcome this problem. Methods In this study, 52 patients without known prior infarction and no stress-induced ischemia on SPECT imaging were examined in both supine and prone position. The results were compared with cardiac magnetic resonance imaging (CMR with delayed-enhancement technique to confirm or exclude myocardial infarction. Results There were 63 defects in supine-position images, 37 of which disappeared in the prone position. None of the 37 defects were associated with myocardial infarction by CMR, indicating that all of them represented attenuation artifacts. Of the remaining 26 defects that did not disappear on prone imaging, myocardial infarction was confirmed by CMR in 2; the remaining 24 had no sign of ischemic infarction but 2 had other kinds of myocardial injuries. In 3 patients, SPECT failed to detect small scars identified by CMR. Conclusion Perfusion defects in the supine position that disappeared in the prone position were caused by attenuation, not myocardial infarction. Hence, imaging in the prone position can help to rule out ischemic heart disease for some patients admitted for SPECT with suspected but not documented ischemic heart disease. This would indicate a better prognosis and prevent unnecessary further investigations and treatment.

  10. SPECT I-123 iodoamphetamine brain imaging

    International Nuclear Information System (INIS)

    Tikofsky, R.S.; Liebman, A.; Hellman, R.S.; Collier, B.D.; Voslar, A.M.

    1988-01-01

    SPECT/IMP studies of 100 patients with a presumptive diagnosis of dementia were performed with a rotating gamma camera 15-20 minutes after intravenous injection of 3.5 mCi of IMP. Of these studies, 43 were interpreted as normal for age; 28 demonstrated decreased but not absent activity bilaterally in posterior parietal/occipital regions (consistent with Alzheimer-type dementia); 28 showed unilateral abnormalities in regional cerebral blood flow consistent with cerebrovascular disease; and one had mixed findings. Based on SPECT/IMP results, further diagnostic testing and/or management would be altered for 72% of patients, suggesting that SPECT/IMP provides valuable data, not available on clinical examination, to guide the evaluation and management of demented patients

  11. SYNCHROTRON X-RAY ABSORPTION-EDGE COMPUTED MICROTOMOGRAPHY IMAGING OF THALLIUM COMPARTMENTALIZATION IN IBERIS INTERMEDIA

    Science.gov (United States)

    Thallium (TI) is an extremely toxic metal which, due to its similarities to K, is readily taken up by plants. Thallium is efficiently hyperaccumulated in Iberis intermedia as TI(I). Distribution and compartmentalization of TI in I. intermedia is highes...

  12. Prediction of cardiac events in patients with transient left ventricle dilation on stress myocardial perfusion SPECT images

    International Nuclear Information System (INIS)

    Fukuda, Hiroshi; Moroi, Masao

    2005-01-01

    The purpose of this study was to investigate cardiac events in patients with transient left ventricle (LV) dilation on stress myocardial perfusion single-photon emission computed tomography images (MPI). Consecutive patients (n=53, 31 males, mean age 71 years) with transient LV dilation on thallium-201 stress MPI (treadmill: 21, pharmacologic: 32) were followed for 17 months. Follow-up time was censored at the occurrence of cardiac death, congestive heart failure, acute coronary syndrome, or revascularization. Images were scored and then the summed stress score (SSS), summed rest score, and summed difference score were calculated. Cardiac death occurred in 3 patients, hospitalization occurred in 8 patients, and revascularization occurred in 20 patients. The combined cardiac event rate was 59% (76% for exercise stress vs 47% for pharmacologic stress, p=0.034.). Cox regression analysis demonstrated that a combination of higher SSS and slow washout rate was the best predictor of cardiac events (hazard ratio=3.3, p=0.029). A high cardiac event rate is associated with transient LV dilation on thallium-201 stress MPI. The event rate is particularly high for exercise stress MPI. Furthermore, a combination of the SSS and thallium-201 slow washout is the best predictor of cardiac events in patients with transient LV dilation. (author)

  13. Assessment of vascularity and permeability in brain tumor using SPECT and [sup 99m]Tc-DTPA-human serum albumin in relation to [sup 201]Tl SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawara, Jyoji; Fukuoka, Seiji; Takahashi, Shuhei; Takahashi, Masaaki; Satoh, Katsuyasu; Suematsu, Katsumi; Nakamura, Jun-ichi (Nakamura Memorial Hospital, Sapporo (Japan))

    1994-02-01

    Single photon emission computed tomography (SPECT) using technetium-99m-DTPA-human serum albumin ([sup 99m]Tc-HSA-D) and thallium-201 chloride ([sup 201]Tl) was simultaneously performed on 25 patients with brain tumors; 10 with brain metastasis, 8 with astrocytoma (Gr. 3) and 7 with meningioma. The early image was obtained 10 minutes after [sup 99m]Tc-HSA-D (740 MBq) injection, and the delayed image was taken 5 hours after the injection. HSA-D index, based on the ratio of [sup 99m]Tc-HSA-D uptake in the tumor versus the cortical area, was calculated on each image, and compared with Tl index (tumor/contralateral cerebrum ratio). HSA-D delayed index was significantly greater than HSA-D early index in all tumor types (p<0.05 by the Wilcoxon ranked sign test). Linear correlation between HSA-D early index and HSA-D delayed index was significant in astrocytoma (GR. 3) (p<0.01) and meningioma (p<0.001), and a linear correlation between HSA-D delayed index and Tl index was significant in astrocytoma (Gr. 3) (p<0.05). It is concluded that HSA-D early index and delayed index could reflect tumor vascularity and permeability, respectively, and provide supplementary information for Tl index. (author).

  14. Clinical features and applications of thallium-201. With reference to scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige

    1988-12-01

    Thallium-201 is not only used widely in myocardial imaging but also has a great potential in other various nuclear medicine imaging studies. This paper presents clinical features and applications of thallium-201, focusing on clinical trials with thallium-201 at the Shinshu University School of Medicine. Thallium-201 myocardial scintigraphy offers information on (1) ventricular position and morphology, (2) hypertrophy or dilatation of the left ventricle, (3) hypertrophy or dilatation of the right ventricle, (4) site and extent of myocardial ischemia and infarct, (5) myocardial blood flow, (6) pulmonary congestion or interstitial pulmonary edema, and (7) pericardial effusion. It can be used in the following evaluation or diagnosis: (1) acute or old myocardial infarction, (2) angina pectoris, (3) treatment strategy or prognosis of ischemic heart disease, (4) treatment strategy or observation of bypass graft or drug therapy, (5) hypertrophic or dilated idiopathic cardiomyopathy, (6) myocardial lesions induced by sarcoidosis, collagen disease, and neuro-muscular disease, (7) ventricular hypertrophy and pulmonary edema, and (9) pericarditis, pericardial effusion, and systolic pericarditis associated with underlying disease. The significance of tumor, liver, bone marrow scintigraphies is also referred to. (Namekawa, K) 69 refs.

  15. Brain SPECT

    International Nuclear Information System (INIS)

    Feistel, H.

    1991-01-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG) [de

  16. Assessing the fate and toxicity of Thallium I and Thallium III to three aquatic organisms.

    Science.gov (United States)

    Rickwood, C J; King, M; Huntsman-Mapila, P

    2015-05-01

    Thallium has been shown to significantly increase in both water and aquatic biota after exposure to metal mine effluent, however, there is a lack of knowledge as to its fate and effect in the aquatic environment. The objectives of this project were to assess (1) fate of thallium by conducting speciation analysis and determining the influence of water quality on toxicity and (2) effects of thallium (I) and (III) on three aquatic species; the algae, Pseudokirchneriella subcapitata, the invertebrate Ceriodaphnia dubia and the vertebrate Pimephales promelas. Speciation analysis proved challenging with poor recovery of thallium (I), however analysis with solutions >125μg/L revealed that over a 7-d period, recovery of thallium (III) was less than 15%, suggesting that the majority of thallium (III) was converted to Thallium (I). It was only in fresh solutions where recovery of Thallium (III) was greater than 80%. The lowest IC25s generated during our effects assessment for both Thallium (I) and (III) were more than 10-fold greater than the highest concentration recorded in receiving environments (8μg/L) and more than 100-fold greater than the current guideline (0.8μg/L). To assess the influence of water quality on thallium toxicity, the concentrations of both potassium and calcium were reduced in dilution water. When potassium was reduced for both C. dubia and P. subcapitata tests, the lowest IC25 generated was 5-fold higher than the current guideline, but within the range of concentrations reported in receiving environments for both Thallium (I) and (III). When calcium was reduced in dilution water, toxicity only increased in the Tl (III) tests with C. dubia; the IC25 for Tl(III), similar to the exposures conducted with reduced potassium, was within the range of total thallium concentrations reported in the receiving environment. Without an accurate, repeatable method to assess thallium speciation at low concentrations it is not possible to draw any firm conclusions

  17. A new reconstruction strategy for image improvement in pinhole SPECT

    International Nuclear Information System (INIS)

    Zeniya, Tsutomu; Watabe, Hiroshi; Kim, Kyeong Min; Teramoto, Noboru; Hayashi, Takuya; Iida, Hidehiro; Aoi, Toshiyuki; Sohlberg, Antti; Kudo, Hiroyuki

    2004-01-01

    Pinhole single-photon emission computed tomography (SPECT) is able to provide information on the biodistribution of several radioligands in small laboratory animals, but has limitations associated with non-uniform spatial resolution or axial blurring. We have hypothesised that this blurring is due to incompleteness of the projection data acquired by a single circular pinhole orbit, and have evaluated a new strategy for accurate image reconstruction with better spatial resolution uniformity. A pinhole SPECT system using two circular orbits and a dedicated three-dimensional ordered subsets expectation maximisation (3D-OSEM) reconstruction method were developed. In this system, not the camera but the object rotates, and the two orbits are at 90 and 45 relative to the object's axis. This system satisfies Tuy's condition, and is thus able to provide complete data for 3D pinhole SPECT reconstruction within the whole field of view (FOV). To evaluate this system, a series of experiments was carried out using a multiple-disk phantom filled with 99m Tc solution. The feasibility of the proposed method for small animal imaging was tested with a mouse bone study using 99m Tc-hydroxymethylene diphosphonate. Feldkamp's filtered back-projection (FBP) method and the 3D-OSEM method were applied to these data sets, and the visual and statistical properties were examined. Axial blurring, which was still visible at the edge of the FOV even after applying the conventional 3D-OSEM instead of FBP for single-orbit data, was not visible after application of 3D-OSEM using two-orbit data. 3D-OSEM using two-orbit data dramatically reduced the resolution non-uniformity and statistical noise, and also demonstrated considerably better image quality in the mouse scan. This system may be of use in quantitative assessment of bio-physiological functions in small animals. (orig.)

  18. Comparison of early thallium-201 scintigraphy and gated blood pool imaging for predicting mortality in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Becker, L.C.; Silverman, K.J.; Bulkley, B.H.; Kallman, C.H.; Mellits, E.D.; Weisfeldt, M.

    1983-01-01

    The extent of abnormality in early thallium-201 and gated cardiac blood pool scintigrams has been reported to be useful for predicting mortality in patients with acute myocardial infarction (AMI). To compare the two techniques, 91 patients admitted consecutively with evident or strongly suspected AMI underwent both imaging studies within 15 hours of the onset of symptoms. Patients with pulmonary edema or shock were excluded. AMI developed in 84% of patients, and 6-month mortality for the entire group was 16%. A thallium defect score of 7.0 or greater identified a subgroup of 14 patients with 64% 6-month mortality rate. Similarly, a left ventricular ejection fraction of 35% or less identified a high-risk subgroup of 10 patients with a 6-month mortality of 60%. Mortality in the remaining patients was 8% for thallium score less than 7 and 11% for ejection fraction greater than 35%. The mortality rate was highest among patients who had concordant high-risk scintigrams (five of six, 83%), lowest in those with concordant low-risk studies (five of 64, 8%) and intermediate in those with discordant results (four of 11, 36%). Of a number of clinical variables, only the appearance of Q waves, peak creatine kinase greater than 1000 IU/I, and history of infarction were significantly associated with mortality. High-risk thallium or blood pool scintigraphic results were significantly more predictive and a thallium score of 7 or greater was more sensitive for detecting nonsurvivors than ejection fraction 35% or less at a similar level of specificity

  19. Advantages of hybrid SPECT-CT imaging in preoperative localization of parathyroid glands in a patient with secondary hyperparathyroidism. A case report

    International Nuclear Information System (INIS)

    Cytawa, Wojciech; Teodorczyk, Jacek; Lass, Piotr

    2013-01-01

    Secondary hyperparathyroidism is a frequent complication of chronic renal failure. Patients resistant to pharmacotherapy are candidates for parathyroidectomy. Invasiveness of surgical treatment can be minimized by precise preoperative localization of parathyroid glands. Imaging modalities routinely used for this purpose are ultrasonography and MIBI-Tc99m scintigraphy. Our case report shows advantages of co-registered computer tomography and conventional SPECT imaging (SPECT/CT) in a patient with advanced secondary hyperparathyroidism successfully treated with surgery. Hybrid SPECT/CT parathyroid imaging enables better surgical planning and is superior to conventional scintigraphy

  20. Cerebral arteriovenous malformations. the relationship between clinical related events and rCBF SPECT imaging

    International Nuclear Information System (INIS)

    Sun Bo; Shi Xiangen

    1996-01-01

    To evaluate the relationship between clinical related events and rCBF SPECT imaging in patients with arteriovenous malformations (AVMs), the radioactive counting difference between normal and lesion site was divided by regional pixel considered as ischemic index (II). II was measured in 20 AVM cases and compared with patients' age, sex,neurological history and the size of lesions. The degree of rCBF reduction correlated with clinical neurological manifestation and showed no significant relationship with the age, sex and size of malformed vessels. II in patients with seizures was higher than that in patients with hemorrhage. The rCBF SPECT imaging may be useful for evaluation of the hemodynamics in AVMs

  1. Evaluation of pancreatic cancers using thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Kume, Norihiko; Suga, Kazuyoshi; Nishigauchi, Kazuya; Uchisako, Hiromichi; Sugano, Ayame; Fujita, Takeshi; Nakanishi, Takashi; Hamasaki, Tatsunori; Suzuki, Takashi

    1995-01-01

    Radionuclide study has not been frequently applied to pancreatic cancers because of the absence of suitable radiopharmaceuticals for their positive depiction. We evaluated thallium-201 chloride ( 201 T1) SPECT for the investigation of pancreatic cancers. The subjects included 24 patients with pancreatic cancer, seven with benign disorders and 10 controls. Each patient fasted prior to the examination for more than 12 hr, and 201 T1 SPECT was obtained 10 min after the injection of 148-222 MBq of 201 T1. When the boundary of tumor uptake of 201 T1 was unclear because of the adjacent physiological liver activity, subtracted SPECT using 99m Tc-phytate was performed to clarify it. 201 T1 did not accumulate in the pancreas of the controls. In contrast, of the 24 pancreatic cancers, 21 demonstrated positive uptake, for a sensitivity rate of 87.5%, and the mean tumor/liver ratio was 0.76±0.16 (range, 0.58-1.28). Abnormal uptake was also noted in three of the seven benign disorders, but with a comparatively lower lesion/liver ratio (range, 0.35-0.51). 201 T1 activity per mg tissue in the resected specimens of two patients with pancreatic cancer revealed higher activity in the tumor than in normal parenchyma. 201 T1 uptake in the five conservatively treated pancreatic cancers showed alteration similar to the serum level of tumor markers. These results suggest that 201 T1 SPECT may have clinical potential for investigating pancreatic cancers as well as for the monitoring of treatment effect. (author)

  2. Present and future of the hybrid imaging method SPECT/CT

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2013-01-01

    Full text: Introduction: Based on the data in the literature and on our 4 year clinical experience applied for the first time in our country hybrid imaging - single photon emission tomography combined with computed tomography (SPECT / CT) it is clear that to obtain comprehensive information about the function and structure of the studied organ; the time for the diagnosis and thus the start of adequate treatment become shorter. The resulting scintigraphic image is with better quality due to CT correction of ‘diffusion’ gamma radiation, which leads to greater diagnostic accuracy. What you will learn: complex imaging method is used mainly in the field of endocrinology, cardiology, oncology, orthopedics, pulmology, neurology, and neurosurgery. It can be prove a given disease by visualization and localization of the organ lesions and determine the stage of the tumor process, to plan the type of subsequent treatment, to follow the effects of the therapy, and to predict the effect of an interventional or miniinvasive surgical procedure. Discussion: The result of the application of the hybrid imaging method is a change in the interpretation of more than half of the studied patients and in the treatment in more than a quarter of them. Conclusion: The clinical indications for SPECT/CT, and evidence of increased diagnostic accuracy compared with self- administered scintigraphic or CT methods are continuous expanded

  3. Improved image quality for asymmetric double-focal cone-beam SPECT

    International Nuclear Information System (INIS)

    Cao, Z.J.; Tsui, B.M.W.

    1993-01-01

    To optimize both spatial resolution and detection efficiency in brain SPECT imaging using a rectangular camera, an asymmetric double-focal cone-beam collimator is proposed with the focal points located near the base plane of the patient's head. To fit the entire head into the field-of-view of the collimator with dimensions of 50cmx40cm and at a radius-of-rotation of 15 cm, the focal lengths of the collimator are 55 and 70 cm, respectively, in the transverse and axial directions. With this geometry, the artifacts in the reconstructed image produced by the Feldkamp algorithm are more severe compared to those in a symmetric cone-beam geometry, due to the larger vertex angle between the top of the head and the base plane. To improve the reconstructed image quality, a fully three-dimensional (3D) reconstruction algorithm developed previously for single-focal cone-beam SPECT was extended to the asymmetric double-focal cone-beam geometry. The algorithm involves nonstationary 2D filtering and a reprojection technique for estimation of the missing data caused by a single-orbit cone-beam geometry. The results from simulation studies with the 3D Defrise slab phantom demonstrated that the fully 3D algorithm provided a much improved image quality in terms of reduced slice-to-slice cross talks and shape elongation compared to that produced by the conventional Feldkamp algorithm

  4. Use of quantitative SPECT/CT reconstruction in 99mTc-sestamibi imaging of patients with renal masses.

    Science.gov (United States)

    Jones, Krystyna M; Solnes, Lilja B; Rowe, Steven P; Gorin, Michael A; Sheikhbahaei, Sara; Fung, George; Frey, Eric C; Allaf, Mohamad E; Du, Yong; Javadi, Mehrbod S

    2018-02-01

    Technetium-99m ( 99m Tc)-sestamibi single-photon emission computed tomography/computed tomography (SPECT/CT) has previously been shown to allow for the accurate differentiation of benign renal oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) apart from other malignant renal tumor histologies, with oncocytomas/HOCTs showing high uptake and renal cell carcinoma (RCC) showing low uptake based on uptake ratios from non-quantitative single-photon emission computed tomography (SPECT) reconstructions. However, in this study, several tumors fell close to the uptake ratio cutoff, likely due to limitations in conventional SPECT/CT reconstruction methods. We hypothesized that application of quantitative SPECT/CT (QSPECT) reconstruction methods developed by our group would provide more robust separation of hot and cold lesions, serving as an imaging framework on which quantitative biomarkers can be validated for evaluation of renal masses with 99m Tc-sestamibi. Single-photon emission computed tomography data were reconstructed using the clinical Flash 3D reconstruction and QSPECT methods. Two blinded readers then characterized each tumor as hot or cold. Semi-quantitative uptake ratios were calculated by dividing lesion activity by background renal activity for both Flash 3D and QSPECT reconstructions. The difference between median (mean) hot and cold tumor uptake ratios measured 0.655 (0.73) with the QSPECT method and 0.624 (0.67) with the conventional method, resulting in increased separation between hot and cold tumors. Sub-analysis of 7 lesions near the separation point showed a higher absolute difference (0.16) between QPSECT and Flash 3D mean uptake ratios compared to the remaining lesions. Our finding of improved separation between uptake ratios of hot and cold lesions using QSPECT reconstruction lays the foundation for additional quantitative SPECT techniques such as SPECT-UV in the setting of renal 99m Tc-sestamibi and other SPECT/CT exams. With robust

  5. Study on the usefulness of whole body SPECT coronal image, MIP image in 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Kawamura, Seiji

    2002-01-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with 67 Ga-citrate ( 67 Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  6. Technical Considerations of Phosphorous-32 Bremsstrahlung SPECT Imaging after Radio embolization of Hepatic Tumors: A Clinical Assessment with a Review of Imaging Parameters

    International Nuclear Information System (INIS)

    Pirayesh, E.; Amoui, M.; Khorrami, M.; Akhlaghpoor, Sh.; Tolooee, Sh.; PoorBeigi, H.; Sheibani, Sh.; Assadi, M.

    2014-01-01

    Bremsstrahlung (BS) imaging during radio embolization (RE) confirms the deposition of radiotracer in hepatic/extrahepatic tumors. The aim of this study is to demonstrate '3 2 P images and to optimize the imaging parameters. Materials and Methods. Thirty-nine patients with variable types of hepatic tumors, treated with the intra-arterial injection of 32 P, were included. All patients underwent BS SPECT imaging 24-72 h after tracer administration, using low energy high resolution (LEHR) (18 patients) or medium energy general purpose (MEGP) (21 patients) collimators. A grading scale from 1 to 4 was used to express the compatibility of the 32 P images with those obtained from CT/MRI. Results. Although the image quality obtained with the MEGP collimator was visually and quantitatively better than with the LEHR (76% concordance score versus 71%, resp.), there was no statistically significant difference between them. Conclusion. The MEGP collimator is the first choice for BS SPECT imaging. However, if the collimator change is time consuming (as in a busy center) or an MEGP collimator is not available, the LEHR collimator could be practical with acceptable images, especially in a SPECT study. In addition, BS imaging is a useful method to confirm the proper distribution of radiotherapeutic agents and has good correlation with anatomical findings.

  7. Assessment of the sources of error affecting the quantitative accuracy of SPECT imaging in small animals

    Energy Technology Data Exchange (ETDEWEB)

    Joint Graduate Group in Bioengineering, University of California, San Francisco and University of California, Berkeley; Department of Radiology, University of California; Gullberg, Grant T; Hwang, Andrew B.; Franc, Benjamin L.; Gullberg, Grant T.; Hasegawa, Bruce H.

    2008-02-15

    Small animal SPECT imaging systems have multiple potential applications in biomedical research. Whereas SPECT data are commonly interpreted qualitatively in a clinical setting, the ability to accurately quantify measurements will increase the utility of the SPECT data for laboratory measurements involving small animals. In this work, we assess the effect of photon attenuation, scatter and partial volume errors on the quantitative accuracy of small animal SPECT measurements, first with Monte Carlo simulation and then confirmed with experimental measurements. The simulations modeled the imaging geometry of a commercially available small animal SPECT system. We simulated the imaging of a radioactive source within a cylinder of water, and reconstructed the projection data using iterative reconstruction algorithms. The size of the source and the size of the surrounding cylinder were varied to evaluate the effects of photon attenuation and scatter on quantitative accuracy. We found that photon attenuation can reduce the measured concentration of radioactivity in a volume of interest in the center of a rat-sized cylinder of water by up to 50percent when imaging with iodine-125, and up to 25percent when imaging with technetium-99m. When imaging with iodine-125, the scatter-to-primary ratio can reach up to approximately 30percent, and can cause overestimation of the radioactivity concentration when reconstructing data with attenuation correction. We varied the size of the source to evaluate partial volume errors, which we found to be a strong function of the size of the volume of interest and the spatial resolution. These errors can result in large (>50percent) changes in the measured amount of radioactivity. The simulation results were compared with and found to agree with experimental measurements. The inclusion of attenuation correction in the reconstruction algorithm improved quantitative accuracy. We also found that an improvement of the spatial resolution through the

  8. Myocardial uptake and clearance of thallium-201 in normal subjects: comparison of dipyridamole-induced hyperemia with exercise stress

    International Nuclear Information System (INIS)

    Ruddy, T.D.; Gill, J.B.; Finkelstein, D.M.; Strauss, H.W.; McKusick, K.A.; Okada, R.D.; Boucher, C.A.

    1987-01-01

    Thallium-201 uptake and clearance after dipyridamole infusion may differ from that after exercise stress because the hemodynamic effects of these two interventions are different. In this study of normal volunteers, thallium kinetics after dipyridamole (n = 13) were determined from three serial image sets (early, intermediate and delayed) and from serial blood samples and compared with thallium kinetics after exercise (n = 15). Absolute myocardial thallium uptake was greater after dipyridamole compared with exercise (p less than 0.0001), although the relative myocardial distribution was similar. The myocardial clearance (%/h) of thallium was slower after dipyridamole than it was after exercise. Comparing dipyridamole and exercise, the differences in clearance were large from the early to the intermediate image (anterior, -11 +/- 17 versus 24 +/- 5, p = 0.0005; 50 degrees left anterior oblique, -7 +/- 11 versus 15 +/- 8, p = 0.004; 70 degrees left anterior oblique, 3 +/- 9 versus 21 +/- 6, p = 0.001). In contrast, the differences in clearance were small from the intermediate to the delayed image (anterior, 15 +/- 4 versus 20 +/- 2, p = 0.025; 50 degrees left anterior oblique, 15 +/- 4 versus 19 +/- 3, p = 0.13; 70 degrees left anterior oblique, 15 +/- 3 versus 18 +/- 2, p = 0.047). Thallium uptake and clearance in the liver, splanchnic region and spleen were greater after dipyridamole (p less than 0.001). Blood thallium levels were greater after dipyridamole (p less than 0.05) and cleared more slowly (p = 0.07). Thus, myocardial thallium-201 uptake and clearance after dipyridamole infusion differ from thallium kinetics after exercise. This difference is, in part, related to associated differences in extracardiac and blood kinetics. Diagnostic criteria for the detection of abnormal thallium-201 clearance must be specific for the type of intervention

  9. U-SPECT-BioFluo : An integrated radionuclide, bioluminescence, and fluorescence imaging platform

    NARCIS (Netherlands)

    Van Oosterom, M.N.; Kreuger, R.; Buckle, T.; Mahn, W.A.; Bunschoten, A.; Josephson, L.; Van Leeuwen, F.W.B.; Beekman, F.J.

    2014-01-01

    Background: In vivo bioluminescence, fluorescence, and single-photon emission computed tomography (SPECT) imaging provide complementary information about biological processes. However, to date these signatures are evaluated separately on individual preclinical systems. In this paper, we introduce a

  10. Usefulness of corregistration and post-processing of MR and interictal SPECT images for localization of epileptogenic focus in children – preliminary report

    International Nuclear Information System (INIS)

    Miśko, Jolanta; Jurkiewicz, Elżbieta; Bekiesińska-Figatowska, Monika; Kamińska, Anna; Bachański, Zbigniew; Chełstowska, Sylwia; Walecki, Jerzy

    2011-01-01

    Children with focal epilepsy unresponsive to anticonvulsant therapy may become surgical candidates. Inter-ictal SPECT (SPECT-IN) studies demonstrate an area of hypoperfusion within the seizure focus in up to 50% of patients. The goal of this study was to evaluate the usefulness of corregistration of MR and SPECT-IN images for localization of the epileptogenic focus. Brain MRI and SPECT-IN were performed in 20 children (mean age 9.5). We found multifocal (3–6 perfusion deficits in 10 patients) or diffuse perfusion deficits (lobar) in all patients. In fused MR and SPECT images we evaluated average activity in volumes-of-interest (VOIs) outlined in each gray matter region with deficits. Average VOI activity below average total brain activity with at least 15% difference to the mirror VOI in the brain cortex on the opposite side of was considered as “true” perfusion deficit (TPD). In all children from our group, MRI and SPECT-IN image fusion and evaluation of TPD allowed to verify most of multifocal or diffuse deficits: in each of 12 patients we found 1 TPD, in each of 6 patients 2 TPD and in each of 2 patients 3 TPD. In 8 patients with 2 or 3 TPD we used scalp EEG or ictal SPECT for identification of one probable location of epileptogenic focus. In children with refractory focal epilepsy, image fusion of MRI and SPECT-IN with evaluation of TPD has potential clinical utility in localization of epileptogenic focus

  11. An automatic MRI/SPECT registration algorithm using image intensity and anatomical feature as matching characters: application on the evaluation of Parkinson's disease

    International Nuclear Information System (INIS)

    Lee, J.-D.; Huang, C.-H.; Weng, Y.-H.; Lin, K.-J.; Chen, C.-T.

    2007-01-01

    Single-photon emission computed tomography (SPECT) of dopamine transporters with 99m Tc-TRODAT-1 has recently been proposed to offer valuable information in assessing the functionality of dopaminergic systems. Magnetic resonance imaging (MRI) and SPECT imaging are important in the noninvasive examination of dopamine concentration in vivo. Therefore, this investigation presents an automated MRI/SPECT image registration algorithm based on a new similarity metric. This similarity metric combines anatomical features that are characterized by specific binding, the mean count per voxel in putamens and caudate nuclei, and the distribution of image intensity that is characterized by normalized mutual information (NMI). A preprocess, a novel two-cluster SPECT normalization algorithm, is also presented for MRI/SPECT registration. Clinical MRI/SPECT data from 18 healthy subjects and 13 Parkinson's disease (PD) patients are involved to validate the performance of the proposed algorithms. An appropriate color map, such as 'rainbow,' for image display enables the two-cluster SPECT normalization algorithm to provide clinically meaningful visual contrast. The proposed registration scheme reduces target registration error from >7 mm for conventional registration algorithm based on NMI to approximately 4 mm. The error in the specific/nonspecific 99m Tc-TRODAT-1 binding ratio, which is employed as a quantitative measure of TRODAT receptor binding, is also reduced from 0.45±0.22 to 0.08±0.06 among healthy subjects and from 0.28±0.18 to 0.12±0.09 among PD patients

  12. SPECT imaging of D{sub 2} dopamine receptors and endogenous dopamine release in mice

    Energy Technology Data Exchange (ETDEWEB)

    Jongen, Cynthia [University Medical Center Utrecht, Image Sciences Institute, Q0S.459, P.O. Box 85500, Utrecht (Netherlands); Bruin, Kora de; Booij, Jan [University of Amsterdam, Academic Medical Center, Department of Nuclear Medicine, Amsterdam (Netherlands); Beekman, Freek [University Medical Center Utrecht, Image Sciences Institute, Q0S.459, P.O. Box 85500, Utrecht (Netherlands); University Medical Center Utrecht, Department of Neuroscience and Pharmacology, Utrecht (Netherlands); Technical University Delft, Department R3, Section Radiation, Detection and Matter, Delft (Netherlands)

    2008-09-15

    The dopamine D{sub 2} receptor (D2R) is important in the mediation of addiction. [{sup 123}I]iodobenzamide (IBZM), a SPECT ligand for the D2R, has been used for in vivo studies of D2R availability in humans, monkeys, and rats. Although mouse models are important in the study of addiction, [{sup 123}I]IBZM has not been used in mice SPECT studies. This study evaluates the use of [{sup 123}I]IBZM for measuring D2R availability in mice. Pharmacokinetics of [{sup 123}I]IBZM in mice were studied with pinhole SPECT imaging after intravenous (i.v.) injection of [{sup 123}I]IBZM (20, 40, and 70 MBq). In addition, the ability to measure the release of endogenous dopamine after amphetamine administration with [{sup 123}I]IBZM SPECT was investigated. Thirdly, i.v. administration, the standard route of administration, and intraperitoneal (i.p.) administration of [{sup 123}I]IBZM were compared. Specific binding of [{sup 123}I]IBZM within the mouse striatum could be clearly visualized with SPECT. Peak specific striatal binding ratios were reached around 90 min post-injection. After amphetamine administration, the specific binding ratios of [{sup 123}I]IBZM decreased significantly (-27.2%; n=6; p=0.046). Intravenous administration of [{sup 123}I]IBZM led to significantly higher specific binding than i.p. administration of the same dose. However, we found that i.v. administration of a dose of 70 MBq [{sup 123}I]IBZM might result in acute ethanol intoxication because ethanol is used as a preparative aid for the routine production of [{sup 123}I]IBZM. Imaging of D2R availability and endogenous dopamine release in mice is feasible using [{sup 123}I]IBZM single pinhole SPECT. Using commercially produced [{sup 123}I]IBZM, a dose of 40 MBq injected i.v. can be recommended. (orig.)

  13. Prognostic value of normal stress-only myocardial perfusion imaging: a comparison between conventional and CZT-based SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yokota, Shu; Ottervanger, Jan Paul; Timmer, Jorik R. [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Mouden, Mohamed; Engbers, Elsemiek [Isala Hospital, Department of Cardiology, Zwolle (Netherlands); Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala Hospital, Department of Nuclear Medicine, Zwolle (Netherlands)

    2016-02-15

    Single photon emission computed tomography (SPECT) myocardial perfusion imaging has proven to have prognostic importance in patients with suspected stable coronary artery disease (CAD). The recently introduced ultrafast cadmium zinc telluride (CZT)-based gamma cameras have been associated with less equivocal findings and more normal interpretations, allowing stress-only imaging to be performed more often. However, it is yet unclear whether normal stress-only CZT SPECT has comparable prognostic value as normally interpreted stress-only conventional SPECT. The study population consisted of 1,650 consecutive patients without known CAD with normal stress-only myocardial perfusion results with either conventional (n = 362) or CZT SPECT (n = 1,288). The incidence of major adverse cardiac events (MACE, all-cause death, non-fatal myocardial infarction and/or coronary revascularization) was compared between the conventional SPECT and CZT SPECT groups. Multivariable analyses using the Cox model were used to adjust for differences in baseline variables. Patients scanned with CZT were less often male (33 vs 39 %), had less often hypercholesterolaemia (41 vs 50 %) and had more often a family history of CAD (57 vs 49 %). At a median follow-up time of 37 months (interquartile range 28-45 months) MACE occurred in 68 patients. The incidence of MACE was 1.5 %/year in the CZT group, compared to 2.0 %/year in the conventional group (p = 0.08). After multivariate analyses, there was a trend to a lower incidence of MACE in the CZT SPECT group (hazard ratio 0.61, 95 % confidence interval 0.35-1.04, p = 0.07). The prognostic value of normal stress-only CZT SPECT is at least comparable and may be even better than that of normal conventional stress SPECT. (orig.)

  14. Assessment of left ventricular function by thallium-201 quantitative gated cardiac SPECT

    International Nuclear Information System (INIS)

    Baba, Akira; Hano, Takuzo; Ohmori, Hisashi; Ibata, Masayo; Kawabe, Tetsuya; Kubo, Takashi; Kimura, Keizo; Nishio, Ichiro

    2002-01-01

    Present study was designed to evaluate the accuracy of the measurement of left ventricular volume by quantitative gated SPECT (QGS) software using 201 Tl and the effect of cutoff frequency of Butterworth prereconstruction filter on the calculation of volume. The RH-2 type cardiac phantom and 20 patients with ischemic heart disease were studied. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were calculated by the QGS software using the various frequency of Butterworth filter. These parameters were evaluated by Simpson's method using left ventriculography (LVG). The volume of the phantom calculated by QGS was under-estimated by 14%. In the clinical study, EDV and ESV measured by QGS were smaller than those obtained from LVG by 10%. When the cutoff frequency of Butterworth filter was 0.43 cycles/cm, the values measured by QGS were best correlated with those by LVG (EDV: r=0.80, p 201 Tl quantitative gated cardiac SPECT can estimate myocardial ischemia and left ventricular function simultaneously. (author)

  15. SPECT/CT and pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Jann [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); The Faroese National Hospital, Department of Medicine, Torshavn (Faroe Islands); Gutte, Henrik [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Herlev Hospital, Copenhagen University Hospital, Department of Radiology, Copenhagen (Denmark); University of Copenhagen, Cluster for Molecular Imaging, Faculty of Health Sciences, Copenhagen (Denmark)

    2014-05-15

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar technique for diagnosing PE. SPECT has been shown to have fewer indeterminate results and a higher diagnostic value. The latest improvement is the combination of a low-dose CT scan with a V/P SPECT scan in a hybrid tomograph. In a study comparing CTPA, planar scintigraphy and SPECT alone, SPECT/CT had the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume coverage per rotation and faster rotation. Furthermore, the dual energy CT technique is a promising modality that can provide functional imaging in combination with anatomical information. Newer high-end CT scanners and SPECT systems are able to visualize smaller subsegmental emboli. However, consensus is lacking regarding the clinical impact and treatment. In the present review, SPECT and SPECT in combination with low-dose CT, CTPA and dual energy CT are discussed in the context of diagnosing PE. (orig.)

  16. Practical reconstruction protocol for quantitative {sup 90}Y bremsstrahlung SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Siman, W.; Mikell, J. K.; Kappadath, S. C., E-mail: skappadath@mdanderson.org [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas 77030 (United States)

    2016-09-15

    Purpose: To develop a practical background compensation (BC) technique to improve quantitative {sup 90}Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. Methods: All images were acquired using medium-energy collimation in six energy windows (EWs), ranging from 70 to 410 keV. The EWs were determined based on the signal-to-background ratio in planar images of an acrylic phantom of different thicknesses (2–16 cm) positioned below a {sup 90}Y source and set at different distances (15–35 cm) from a gamma camera. The authors adapted the widely used EW-based scatter-correction technique by modeling the BC as scaled images. The BC EW was determined empirically in SPECT/CT studies using an IEC phantom based on the sphere activity recovery and residual activity in the cold lung insert. The scaling factor was calculated from 20 clinical planar {sup 90}Y images. Reconstruction parameters were optimized in the same SPECT images for improved image quantification and contrast. A count-to-activity calibration factor was calculated from 30 clinical {sup 90}Y images. Results: The authors found that the most appropriate imaging EW range was 90–125 keV. BC was modeled as 0.53× images in the EW of 310–410 keV. The background-compensated clinical images had higher image contrast than uncompensated images. The maximum deviation of their SPECT calibration in clinical studies was lowest (<10%) for SPECT with attenuation correction (AC) and SPECT with AC + BC. Using the proposed SPECT-with-AC + BC reconstruction protocol, the authors found that the recovery coefficient of a 37-mm sphere (in a 10-mm volume of interest) increased from 39% to 90% and that the residual activity in the lung insert decreased from 44% to 14% over that of SPECT images with AC alone. Conclusions: The proposed EW-based BC model was developed for {sup 90}Y bremsstrahlung imaging. SPECT with AC + BC gave improved lesion

  17. Preoperative imaging in primary hyperparathyroidism. Role of thallium-technetium subtraction scintigraphy

    International Nuclear Information System (INIS)

    Foster, G.S.; Bekerman, C.; Blend, M.J.; Byrom, E.; Pinsky, S.M.

    1989-01-01

    Primary hyperparathyroidism, although often silent clinically, may lead to significant morbidity if it remains untreated. In more than 95% of all cases the cause is a parathyroid adenoma or glandular hyperplasia. Regression of disease follows successful surgical excision of the abnormal parathyroid gland. Recurrent or persistent hyperparathyroidism is most commonly caused by solitary adenomas, which may have an ectopic location. Preoperative localization of lesions may improve postoperative cure rates and decrease morbidity. Thallium T1 201 chloride-technetium Tc 99m pertechnetate subtraction scintigraphy was performed on 15 patients with primary hyperparathyroidism. The sensitivity and specificity for detection of abnormal glands were 90% and 95%, respectively. False-positive or false-negative results were minimize by strict adherence to a protocol and by the use of well-defined diagnostic criteria. Because of the superior sensitivity and specificity, this modality should be the primary imaging method of choice for preoperative evaluation of primary hyperparathyroidism. The relative role of other imaging modalities is also discussed. 31 references

  18. The early diagnostic value of oral acetazolamide load combined with SPECT rCBF imaging in patients with transient ischemia attack in brain

    International Nuclear Information System (INIS)

    Liu Xintong; Zheng Zhiping; Qiao Suixian; Tang Anwu

    2001-01-01

    Objective: In order to assess the diagnostic value of acetazolamide (ACZ) combined with rCBF-SPECT imaging in patients with transient ischemia attack (TIA). Methods: SPECT imaging was performed before and after oral ACZ with visual and semiquantitative analysis of the images. Blood gas analysis was done before and after ACZ administration either. Results: After ACZ loading, in normal group, 99 Tc m -ECD was distributed symmetrically on correspondent parts of the brain and rCBF was generally increased. The blood pH was decreased and blood PCO 2 was increased, respectively in TIA group, the positive rate of hypoperfusion foci on SPECT images were increased from 5/6 to 6/6 in symptomatic patients and from 60% to 92% in asymptomatic patients. The total positive rate was 93%. Conclusion: Oral ACZ before SPECT imaging is a simple, reliable way for early diagnosis in patients with TIA

  19. I-123 Iofetamine SPECT scan in children with neurological disorders

    International Nuclear Information System (INIS)

    Flamini, J.R.; Konkol, R.J.; Wells, R.G.; Sty, J.R.

    1990-01-01

    I-123 Iofetamine (IMP) single photon emission computed tomography (SPECT) imaging of the brain in 42 patients (ages 14 days to 23 years) was compared with other localizing studies in children with neurological diseases. All had an EEG and at least one imaging study of the brain (computed tomography (CT) or magnetic resonance imaging (MRI), or both). Seventy-eight percent of the patients had an EEG within 24-72 hours of the IMP-SPECT scan. Thirty-five (83%) had a history of seizures, and the remainder had other neurological conditions without a history of seizures. In most cases, a normal EEG reading with normal CT or MRI result predicted a normal SPECT study. When the EEG was abnormal the majority of the IMP-SPECT scans were abnormal and localized the abnormality to the same region. A comparison with CT and MRI showed that structural abnormalities involving the cortex were usually well demonstrated with IMP-SPECT imaging. Structural lesions confined to the white matter were generally not detectable with IMP-SPECT. In a few cases, SPECT scans revealed abnormalities in deep brain areas not identified by EEG. IMP-SPECT imaging is a valuable technique for the detection and localization of abnormal cerebral metabolic activity in children with seizure disorders. A correlation with CT or MRI is essential for proper interpretation of abnormalities detected with IMP SPECT imaging

  20. Creation and evaluation of complementary composite three-dimensional image in various brain diseases. An application of three-dimensional brain SPECT image and three-dimensional CT image

    International Nuclear Information System (INIS)

    Seiki, Yoshikatsu; Shibata, Iekado; Mito, Toshiaki; Sugo, Nobuo

    2000-01-01

    The purpose of this study was to develop 3D composite images for use in functional and anatomical evaluation of various cerebral pathologies. Imaging studies were performed in normal volunteers, patients with hydrocephalus and patients with brain tumor (meningioma and metastatic tumor) using a three-detector SPECT system (Prism 3000) and helical CT scanner (Xvigor). 123 I-IMP was used in normal volunteers and patients with hydrocephalus, and 201 TLCL in patients with brain tumor. An Application Visualization System-Medical Viewer (AVS-MV) was used on a workstation (Titan 2) to generate 3D images. A new program was developed by synthesizing surface rendering and volume rendering techniques. The clinical effects of shunt operations were successfully evaluated in patients with hydrocephalus by means of translucent 3D images of the deep brain. Changes in the hypoperfusion area around the cerebral ventricle were compared with morphological changes in the cerebral ventricle on CT. In addition to the information concerning the characteristics of brain tumors and surrounding edemas, hemodynamic changes and changeable hypoperfusion areas around the tumors were visualized on 3D composite CT and SPECT images. A new method of generating 3D composite images of CT and SPECT was developed by combining graphic data from different systems on the same workstation. Complementary 3D composite images facilitated quantitative analysis of brain volume and functional analysis in various brain diseases. (author)