WorldWideScience

Sample records for spect preclinical studies

  1. Preclinical imaging characteristics and quantification of Platinum-195m SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Aalbersberg, E.A.; Wit-van der Veen, B.J. de; Vegt, E.; Vogel, Wouter V. [The Netherlands Cancer Institute (NKI-AVL), Department of Nuclear Medicine, Amsterdam (Netherlands); Zwaagstra, O.; Codee-van der Schilden, K. [Nuclear Research and Consultancy Group (NRG), Petten (Netherlands)

    2017-08-15

    In vivo biodistribution imaging of platinum-based compounds may allow better patient selection for treatment with chemo(radio)therapy. Radiolabeling with Platinum-195m ({sup 195m}Pt) allows SPECT imaging, without altering the chemical structure or biological activity of the compound. We have assessed the feasibility of {sup 195m}Pt SPECT imaging in mice, with the aim to determine the image quality and accuracy of quantification for current preclinical imaging equipment. Enriched (>96%) {sup 194}Pt was irradiated in the High Flux Reactor (HFR) in Petten, The Netherlands (NRG). A 0.05 M HCl {sup 195m}Pt-solution with a specific activity of 33 MBq/mg was obtained. Image quality was assessed for the NanoSPECT/CT (Bioscan Inc., Washington DC, USA) and U-SPECT{sup +}/CT (MILabs BV, Utrecht, the Netherlands) scanners. A radioactivity-filled rod phantom (rod diameter 0.85-1.7 mm) filled with 1 MBq {sup 195m}Pt was scanned with different acquisition durations (10-120 min). Four healthy mice were injected intravenously with 3-4 MBq {sup 195m}Pt. Mouse images were acquired with the NanoSPECT for 120 min at 0, 2, 4, or 24 h after injection. Organs were delineated to quantify {sup 195m}Pt concentrations. Immediately after scanning, the mice were sacrificed, and the platinum concentration was determined in organs using a gamma counter and graphite furnace - atomic absorption spectroscopy (GF-AAS) as reference standards. A 30-min acquisition of the phantom provided visually adequate image quality for both scanners. The smallest visible rods were 0.95 mm in diameter on the NanoSPECT and 0.85 mm in diameter on the U-SPECT{sup +}. The image quality in mice was visually adequate. Uptake was seen in the kidneys with excretion to the bladder, and in the liver, blood, and intestine. No uptake was seen in the brain. The Spearman correlation between SPECT and gamma counter was 0.92, between SPECT and GF-AAS it was 0.84, and between GF-AAS and gamma counter it was0.97 (all p < 0

  2. Initial Investigation of preclinical integrated SPECT and MR imaging.

    Science.gov (United States)

    Hamamura, Mark J; Ha, Seunghoon; Roeck, Werner W; Wagenaar, Douglas J; Meier, Dirk; Patt, Bradley E; Nalcioglu, Orhan

    2010-02-01

    Single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high-spatial resolution anatomical information as well as complementary functional information. In this study, we utilized a dual modality SPECT/MRI (MRSPECT) system to investigate the integration of SPECT and MRI for improved image accuracy. The MRSPECT system consisted of a cadmium-zinc-telluride (CZT) nuclear radiation detector interfaced with a specialized radiofrequency (RF) coil that was placed within a whole-body 4 T MRI system. The importance of proper corrections for non-uniform detector sensitivity and Lorentz force effects was demonstrated. MRI data were utilized for attenuation correction (AC) of the nuclear projection data and optimized Wiener filtering of the SPECT reconstruction for improved image accuracy. Finally, simultaneous dual-imaging of a nude mouse was performed to demonstrated the utility of co-registration for accurate localization of a radioactive source.

  3. [Studies of biologic activation associated with molecular receptor increase and tumor response in ChL6/L6 protocol patients; Studies in phantoms; Quantitative SPECT; Preclinical studies; and Clinical studies]. DOE annual report, 1994-95

    International Nuclear Information System (INIS)

    DeNardo, S.J.

    1995-01-01

    The authors describe results which have not yet been published from their associated studies listed in the title. For the first, they discuss Lym-1 single chain genetically engineered molecules, analysis of molecular genetic coded messages to enhance tumor response, and human dosimetry and therapeutic human use radiopharmaceuticals. Studies in phantoms includes a discussion of planar image quantitation, counts coincidence correction, organ studies, tumor studies, and 90 Y quantitation with Bremsstrahlung imaging. The study on SPECT discusses attenuation correction and scatter correction. Preclinical studies investigated uptake of 90 Y-BrE-3 in mice using autoradiography. Clinical studies discuss image quantitation verses counts from biopsy samples, S factors for radiation dose calculation, 67 Cu imaging studies for lymphoma cancer, and 111 In MoAb imaging studies for breast cancer to predict 90 Y MoAb therapy

  4. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    Science.gov (United States)

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  5. Preclinical studies of dendrimer prodrugs.

    Science.gov (United States)

    Kojima, Chie

    2015-01-01

    Dendrimers are synthetic macromolecules with well-defined structures bearing a wide variety of functional groups on their periphery. These groups can be used to conjugate bioactive molecules such as drugs, ligands and imaging agents. Dendrimer prodrugs can be used to improve the water solubility and pharmacokinetic properties of the corresponding free drugs. This article summarizes preclinical studies pertaining to the use of drug-dendrimer conjugates as dendrimer prodrugs for the treatments of various diseases, including cancer and inflammatory diseases. A wide range of anticancer drugs have been conjugated to dendrimers via biodegradable linkers. The side effects of the parent drugs can be markedly reduced using dendrimer prodrugs, with some drugs showing improved efficacy. Anti-inflammatory agents have also been conjugated to dendrimers and used to treat a number of inflammatory diseases. Drug-dendrimer conjugates are preferable to drug-dendrimer complexes, where the use of degradable linkers is critical to the release of the drug. Polyethylene glycol and/or ligands can be added to a dendrimer prodrug, which is useful for the targeting of affected tissues. Imaging probes can also be incorporated into dendrimer prodrugs for the simultaneous delivery of therapeutic and diagnostic agents as 'theranostics.'

  6. Ventilation-perfused studies using SPECT

    International Nuclear Information System (INIS)

    Zwijnenburg, A.

    1989-01-01

    A method for the quantitative analysis of ventilation-perfusion SPECT studies is decribed and an effort is made to evaluate its usefullness. The technical details of the emthod are described. In the the transaxial reconstructions of the tomographic studies the contour of the lungs is detected and regional values of lung volume, ventilation, perfusion and ventilation-perfusion ratios are calculated. The method is operator independent. The lung volume calculations from the SPECT studies are validated by comparing them with lung volume measurements using the helium dilution technique. A good correlation (r=0.91) was found between the two volumes. SPECT volume was greater than the volume measured with helium dilution, which was attributed to non-gas-containing structures in the. lungs. The use of ventilation-perfusion ratio SPECT is described to evaluate the effect of ionizing radiation on the lungs in patients treated with mantle field irradiation for Hodgkin's disease. Perfusion changes appear as early as 2 months after the start of irradiation. Ventilation changes appear later and relatively minor. No changes are seen outside the radiation portals. The ventilation-perfusion inequality in pulmonary sarcoidosis is treated. It is suggested that the decrease D LCO in these patients may be partly due to an even distribution of ventilation perfusion ratios. An effort is made to establish the properties of a new tracer used for the assessment of the metabolic function of the pulmonary endothelium. The lung uptake of I-123 IMP mimics the distribution of a perfusion tracer and it is suggested that this tracer may be useful for the early detection of pulmonary vascular damage, even when blood flow is still intact. Some aspects of the use of Kr-81m as a ventilation tracer are discussed as well as the effect of noise on Kr-81m SPECT reconstructions. (author). 146 refs.; 39 figs.; 8 tabs

  7. Neuropharmacological studies with SPECT in neuropsychiatric disorders

    Energy Technology Data Exchange (ETDEWEB)

    Heinz, Andreas; Jones, Douglas W.; Raedler, Thomas; Coppola, Richard; Knable, Michael B.; Weinberger, Daniel R. E-mail: weinberd@intra.nimh.nih.gov

    2000-10-01

    The last decade saw a rapid development of single photon emission computed tomography (SPECT) from a tool to assess cerebral blood flow to the study of specific neurotransmitter systems. Because of the relatively long half-life of SPECT radioisotopes, it is practical to measure the availability of neuroreceptors and transporters in conditions approaching equilibrium. The cost-efficiency of SPECT allowed studies in relatively large samples of patients with various neuropsychiatric disorders. We have applied this approach in studies of dopaminergic, serotonergic, and muscarinergic neurotransmission in patients with dementia, extrapyramidal disorders, schizophrenia, and alcoholism. No simple associations were observed between a single defect in one neurotransmitter system and a certain neuropsychiatric disease. Instead, complex dysfunction of several neurotransmitter systems in multiple, partially connected brain circuits have been implicated. Treatment effects also have been characterized. Microdialysis and neurotransmitter depletion studies showed that most radioligands and endogenous neurotransmitters compete for binding at receptors and transporters. Future research directions include the assessment of endogenous neurotransmitter concentrations measured by depletion studies and of genetic effects on neuroreceptor and transporter expression.

  8. Neuropharmacological studies with SPECT in neuropsychiatric disorders

    International Nuclear Information System (INIS)

    Heinz, Andreas; Jones, Douglas W.; Raedler, Thomas; Coppola, Richard; Knable, Michael B.; Weinberger, Daniel R.

    2000-01-01

    The last decade saw a rapid development of single photon emission computed tomography (SPECT) from a tool to assess cerebral blood flow to the study of specific neurotransmitter systems. Because of the relatively long half-life of SPECT radioisotopes, it is practical to measure the availability of neuroreceptors and transporters in conditions approaching equilibrium. The cost-efficiency of SPECT allowed studies in relatively large samples of patients with various neuropsychiatric disorders. We have applied this approach in studies of dopaminergic, serotonergic, and muscarinergic neurotransmission in patients with dementia, extrapyramidal disorders, schizophrenia, and alcoholism. No simple associations were observed between a single defect in one neurotransmitter system and a certain neuropsychiatric disease. Instead, complex dysfunction of several neurotransmitter systems in multiple, partially connected brain circuits have been implicated. Treatment effects also have been characterized. Microdialysis and neurotransmitter depletion studies showed that most radioligands and endogenous neurotransmitters compete for binding at receptors and transporters. Future research directions include the assessment of endogenous neurotransmitter concentrations measured by depletion studies and of genetic effects on neuroreceptor and transporter expression

  9. Review of SPECT collimator selection, optimization, and fabrication for clinical and preclinical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Van Audenhaege, Karen, E-mail: karen.vanaudenhaege@ugent.be; Van Holen, Roel; Vandenberghe, Stefaan; Vanhove, Christian [Department of Electronics and Information Systems, MEDISIP-IBiTech, Ghent University–iMinds Medical IT, De Pintelaan 185 block B/5, Ghent B-9000 (Belgium); Metzler, Scott D. [Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Moore, Stephen C. [Division of Nuclear Medicine, Department of Radiology, Brigham and Women’s Hospital and Harvard Medical School, 75 Francis Street, Boston, Massachusetts 02115 (United States)

    2015-08-15

    In single photon emission computed tomography, the choice of the collimator has a major impact on the sensitivity and resolution of the system. Traditional parallel-hole and fan-beam collimators used in clinical practice, for example, have a relatively poor sensitivity and subcentimeter spatial resolution, while in small-animal imaging, pinhole collimators are used to obtain submillimeter resolution and multiple pinholes are often combined to increase sensitivity. This paper reviews methods for production, sensitivity maximization, and task-based optimization of collimation for both clinical and preclinical imaging applications. New opportunities for improved collimation are now arising primarily because of (i) new collimator-production techniques and (ii) detectors with improved intrinsic spatial resolution that have recently become available. These new technologies are expected to impact the design of collimators in the future. The authors also discuss concepts like septal penetration, high-resolution applications, multiplexing, sampling completeness, and adaptive systems, and the authors conclude with an example of an optimization study for a parallel-hole, fan-beam, cone-beam, and multiple-pinhole collimator for different applications.

  10. Simulation study of the second-generation MR-compatible SPECT system based on the inverted compound-eye gamma camera design

    Science.gov (United States)

    Lai, Xiaochun; Meng, Ling-Jian

    2018-02-01

    In this paper, we present simulation studies for the second-generation MRI compatible SPECT system, MRC-SPECT-II, based on an inverted compound eye (ICE) gamma camera concept. The MRC-SPECT-II system consists of a total of 1536 independent micro-pinhole-camera-elements (MCEs) distributed in a ring with an inner diameter of 6 cm. This system provides a FOV of 1 cm diameter and a peak geometrical efficiency of approximately 1.3% (the typical levels of 0.1%-0.01% found in modern pre-clinical SPECT instrumentations), while maintaining a sub-500 μm spatial resolution. Compared to the first-generation MRC-SPECT system (MRC-SPECT-I) (Cai 2014 Nucl. Instrum. Methods Phys. Res. A 734 147-51) developed in our lab, the MRC-SPECT-II system offers a similar resolution with dramatically improved sensitivity and greatly reduced physical dimension. The latter should allow the system to be placed inside most clinical and pre-clinical MRI scanners for high-performance simultaneous MRI and SPECT imaging.

  11. SP-ECT imaging and its physical study

    International Nuclear Information System (INIS)

    Kinoshita, Fujimi

    1983-01-01

    Recently, more than a hundred hospitals are provided with SPECT system for clinical examination in Japan. However, a standardization of measuring method and performance test of the systems is ont yet made. We have been studying some basic problems of SPECT system with special phantoms originaly designed by ourselves. We got a conclusion that a standardized phantom is necessary for comparing performances between SPECT systems. In clinical experiences with 3,332 cases, we think that SPECT image combined with conventional image presents much more informations for accurate diagnosis, especially in brain, bone and tumor imagings. Synthesized image of SPECT and XCT, double tracer image and transmission image are useful to visualize the body contour and the clinical diagnosis. (author)

  12. Recommendations for Benchmarking Preclinical Studies of Nanomedicines.

    Science.gov (United States)

    Dawidczyk, Charlene M; Russell, Luisa M; Searson, Peter C

    2015-10-01

    Nanoparticle-based delivery systems provide new opportunities to overcome the limitations associated with traditional small-molecule drug therapy for cancer and to achieve both therapeutic and diagnostic functions in the same platform. Preclinical trials are generally designed to assess therapeutic potential and not to optimize the design of the delivery platform. Consequently, progress in developing design rules for cancer nanomedicines has been slow, hindering progress in the field. Despite the large number of preclinical trials, several factors restrict comparison and benchmarking of different platforms, including variability in experimental design, reporting of results, and the lack of quantitative data. To solve this problem, we review the variables involved in the design of preclinical trials and propose a protocol for benchmarking that we recommend be included in in vivo preclinical studies of drug-delivery platforms for cancer therapy. This strategy will contribute to building the scientific knowledge base that enables development of design rules and accelerates the translation of new technologies. ©2015 American Association for Cancer Research.

  13. Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging

    International Nuclear Information System (INIS)

    Magota, Keiichi; Kubo, Naoki; Kuge, Yuji; Nishijima, Ken-ichi; Zhao, Songji; Tamaki, Nagara

    2011-01-01

    We investigated the performance of the Inveon small-animal PET/SPECT/CT system and compared the imaging capabilities of the SPECT and PET components. For SPECT, the energy resolution, tomographic spatial resolution and system sensitivity were evaluated with a 99m Tc solution using a single pinhole collimator. For PET, the spatial resolution, absolute sensitivity, scatter fraction and peak noise equivalent count were evaluated. Phantoms and a normal rat were scanned to compare the imaging capabilities of SPECT and PET. The SPECT spatial resolution was 0.84 mm full-width at half-maximum (FWHM) at a radius of rotation of 25 mm using a 0.5-mm pinhole aperture collimator, while the PET spatial resolution was 1.63 mm FWHM at the centre. The SPECT system sensitivity at a radius of rotation of 25 mm was 35.3 cps/MBq (4 x 10 -3 %) using the 0.5-mm pinhole aperture, while the PET absolute sensitivity was 3.2% for 350-650 keV and 3.432 ns. Accordingly, the volume sensitivity of PET was three orders of magnitude higher than that of SPECT. This integrated PET/SPECT/CT system showed high performance with excellent spatial resolution for SPECT and sensitivity for PET. Based on the tracer availability and system performance, SPECT and PET have complementary roles in multimodality small-animal imaging. (orig.)

  14. Preclinical Studies for Cartilage Repair

    Science.gov (United States)

    Hurtig, Mark B.; Buschmann, Michael D.; Fortier, Lisa A.; Hoemann, Caroline D.; Hunziker, Ernst B.; Jurvelin, Jukka S.; Mainil-Varlet, Pierre; McIlwraith, C. Wayne; Sah, Robert L.; Whiteside, Robert A.

    2011-01-01

    Investigational devices for articular cartilage repair or replacement are considered to be significant risk devices by regulatory bodies. Therefore animal models are needed to provide proof of efficacy and safety prior to clinical testing. The financial commitment and regulatory steps needed to bring a new technology to clinical use can be major obstacles, so the implementation of highly predictive animal models is a pressing issue. Until recently, a reductionist approach using acute chondral defects in immature laboratory species, particularly the rabbit, was considered adequate; however, if successful and timely translation from animal models to regulatory approval and clinical use is the goal, a step-wise development using laboratory animals for screening and early development work followed by larger species such as the goat, sheep and horse for late development and pivotal studies is recommended. Such animals must have fully organized and mature cartilage. Both acute and chronic chondral defects can be used but the later are more like the lesions found in patients and may be more predictive. Quantitative and qualitative outcome measures such as macroscopic appearance, histology, biochemistry, functional imaging, and biomechanical testing of cartilage, provide reliable data to support investment decisions and subsequent applications to regulatory bodies for clinical trials. No one model or species can be considered ideal for pivotal studies, but the larger animal species are recommended for pivotal studies. Larger species such as the horse, goat and pig also allow arthroscopic delivery, and press-fit or sutured implant fixation in thick cartilage as well as second look arthroscopies and biopsy procedures. PMID:26069576

  15. SPECT and PET imaging of angiogenesis and arteriogenesis in pre-clinical models of myocardial ischemia and peripheral vascular disease

    Energy Technology Data Exchange (ETDEWEB)

    Hendrikx, Geert [Maastricht University Medical Centre MUMC+, Department of Nuclear Medicine, Postbox 5800, Maastricht (Netherlands); Maastricht University, Cardiovascular Research Institute Maastricht (CARIM), Maastricht (Netherlands); Voeoe, Stefan [Maastricht University Medical Centre MUMC+, Department of Nuclear Medicine, Postbox 5800, Maastricht (Netherlands); Bauwens, Matthias [Maastricht University Medical Centre MUMC+, Department of Nuclear Medicine, Postbox 5800, Maastricht (Netherlands); Maastricht University, School of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht (Netherlands); Post, Mark J. [Maastricht University, Department of Physiology, Maastricht (Netherlands); Maastricht University, Cardiovascular Research Institute Maastricht (CARIM), Maastricht (Netherlands); Mottaghy, Felix M. [Maastricht University Medical Centre MUMC+, Department of Nuclear Medicine, Postbox 5800, Maastricht (Netherlands); University Hospital, RWTH Aachen University, Department of Nuclear Medicine, Aachen (Germany)

    2016-12-15

    The extent of neovascularization determines the clinical outcome of coronary artery disease and other occlusive cardiovascular disorders. Monitoring of neovascularization is therefore highly important. This review article will elaborately discuss preclinical studies aimed at validating new nuclear angiogenesis and arteriogenesis tracers. Additionally, we will briefly address possible obstacles that should be considered when designing an arteriogenesis radiotracer. A structured medline search was the base of this review, which gives an overview on different radiopharmaceuticals that have been evaluated in preclinical models. Neovascularization is a collective term used to indicate different processes such as angiogenesis and arteriogenesis. However, while it is assumed that sensitive detection through nuclear imaging will facilitate translation of successful therapeutic interventions in preclinical models to the bedside, we still lack specific tracers for neovascularization imaging. Most nuclear imaging research to date has focused on angiogenesis, leaving nuclear arteriogenesis imaging largely overlooked. Although angiogenesis is the process which is best understood, there is no scarcity in theoretical targets for arteriogenesis imaging. (orig.)

  16. The use of SPECT in the study of depression

    International Nuclear Information System (INIS)

    Yu Jing; The Second Affiliated Hospital of Dalian Medical Univ., Dalian; Tang Yiyuan

    2007-01-01

    Functional imaging is an effective methods in the study of psychological disturbances. The SPECT imaging methods commonly used in the study of depression are cerebral blood flow imaging, cerebral metabolic imaging and neuroreceptor imaging, which reflect the cerebral blood perfusion, cerebral metabolism, and the distribution and function of neuroreceptors respectively. The techniques in data processing include and statistical parametric mapping. This review summarizes the feature of the imaging and data processing methods, the manifestation of SPECT images in depressive patients, the brain region with abnormal blood flow and the findings in neuroreceptor imaging; analyzes the problems in current reports and prospects future studies. (authors)

  17. Simultaneous acquisition of (99m)Tc- and (123)I-labeled radiotracers using a preclinical SPECT scanner with CZT detectors.

    Science.gov (United States)

    Kobayashi, Masato; Matsunari, Ichiro; Nishi, Kodai; Mizutani, Asuka; Miyazaki, Yoshiharu; Ogai, Kazuhiro; Sugama, Jyunko; Shiba, Kazuhiro; Kawai, Keiichi; Kinuya, Seigo

    2016-05-01

    Simultaneous acquisition of (99m)Tc and (123)I was evaluated using a preclinical SPECT scanner with cadmium zinc telluride (CZT)-based detectors. 10-ml cylindrical syringes contained about 37 MBq (99m)Tc-tetrofosmin ((99m)Tc-TF) or 37 MBq (123)I-15-(p-iodophenyl)-3R,S-methyl pentadecanoic acid ((123)I-BMIPP) were used to assess the relationship between these SPECT radioactive counts and radioactivity. Two 10-ml syringes contained 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP to assess the influence of (99m)Tc upscatter and (123)I downscatter, respectively. A rat-sized cylindrical phantom also contained both 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. The two 10-ml syringes and phantom were scanned using a pinhole collimator for rats. Myocardial infarction model rats were examined using 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. Two 1-ml syringes contained 105 MBq (99m)Tc-labeled hexamethylpropyleneamine oxime ((99m)Tc-HMPAO) and 35 MBq (123)I-labeled N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl) nortropane ((123)I-FP-CIT). The two 1-ml syringes were scanned using a pinhole collimator for mice. Normal mice were examined using 105 MBq (99m)Tc-HMPAO and 35 MBq (123)I-FP-CIT. The relationship between SPECT radioactive counts and radioactivity was excellent. Downscatter contamination of (123)I-BMIPP exhibited fewer radioactive counts for 300 MBq (99m)Tc-TF without scatter correction (SC) in 125-150 keV. There was no upscatter contamination of (99m)Tc-TF in 150-175 keV. In the rat-sized phantom, the radioactive count ratio decreased to 4.0 % for 300 MBq (99m)Tc-TF without SC in 125-150 keV. In the rats, myocardial images and radioactive counts of (99m)Tc-TF with the dual tracer were identical to those of the (99m)Tc-TF single injection. Downscatter contamination of (123)I-FP-CIT was 4.2 % without SC in 125-150 keV. In the first injection of (99m)Tc-HMPAO and second injection of (123)I-FP-CIT, brain images and radioactive counts

  18. Usefulness of CT based SPECT Fusion Image in the lung Disease : Preliminary Study

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Lyu, Kwang Yeul; Kim, Tae Hyung; Shin, Ji Yun

    2012-01-01

    Recently, SPECT/CT system has been applied to many diseases, however, the application is not extensively applied at pulmonary disease. Especially, in case that, the pulmonary embolisms suspect at the CT images, SPECT is performed. For the accurate diagnosis, SPECT/CT tests are subsequently undergoing. However, without SPECT/CT, there are some limitations to apply these procedures. With SPECT/CT, although, most of the examination performed after CT. Moreover, such a test procedures generate unnecessary dual irradiation problem to the patient. In this study, we evaluated the amount of unnecessary irradiation, and the usefulness of fusion images of pulmonary disease, which independently acquired from SPECT and CT. Using NEMA PhantomTM (NU2-2001), SPECT and CT scan were performed for fusion images. From June 2011 to September 2010, 10 patients who didn't have other personal history, except lung disease were selected (male: 7, female: 3, mean age: 65.3±12.7). In both clinical patient and phantom data, the fusion images scored higher than SPECT and CT images. The fusion images, which is combined with pulmonary vessel images from CT and functional images from SPECT, can increase the detection possibility in detecting pulmonary embolism in the resin of lung parenchyma. It is sure that performing SPECT and CT in integral SPECT/CT system were better. However, we believe this protocol can give more informative data to have more accurate diagnosis in the hospital without integral SPECT/CT system.

  19. Brain SPECT

    International Nuclear Information System (INIS)

    Feistel, H.

    1991-01-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG) [de

  20. Preparation and preclinical pharmacological study on a novel bone imaging agent 99mTc-EMIDP

    International Nuclear Information System (INIS)

    Lin Jianguo; Luo Shineng; Chen Chuanqing; Qiu Ling; Wang Yan; Cheng Wen; Ye Wanzhong; Xia Yongmei

    2010-01-01

    A novel zoledronic acid (ZL) derivative, 1-hydroxy-2-(2-ethyl-4-methyl-1H-imidazol-1-yl)ethane-1,1-diyldiphosphonic acid (EMIDP), was prepared and labeled with 99m Tc successfully in a high labeling yield and good stability in vitro. The preclinical pharmacological properties of 99m Tc-EMIDP were investigated and compared with 99m Tc-MDP and 99m Tc-ZL. The studies of biodistribution in mice and SPECT bone imaging of the rabbit suggest that 99m Tc-EMIDP has highly selective uptake in the skeletal system and rapid clearance in the soft tissues. The present findings indicate that 99m Tc-EMIDP holds great potential for bone scintigraphy.

  1. Study partners should be required in preclinical Alzheimer's disease trials.

    Science.gov (United States)

    Grill, Joshua D; Karlawish, Jason

    2017-12-06

    In an effort to intervene earlier in Alzheimer's disease (AD), clinical trials are testing promising candidate therapies in preclinical disease. Preclinical AD trial participants are cognitively normal, functionally independent, and autonomous decision-makers. Yet, like AD dementia trials, preclinical trials require dual enrollment of a participant and a knowledgeable informant, or study partner. The requirement of dyadic enrollment is a barrier to recruitment and may present unique ethical challenges. Despite these limitations, the requirement should continue. Study partners may be essential to ensure participant safety and wellbeing, including overcoming distress related to biomarker disclosure and minimizing risk for catastrophic reactions and suicide. The requirement may maximize participant retention and ensure data integrity, including that study partners are the source of data that will ultimately instruct whether a new treatment has a clinical benefit and meaningful impact on the population health burden associated with AD. Finally, study partners are needed to ensure the scientific and clinical value of trials. Preclinical AD will represent a new model of care, in which persons with no symptoms are informed of probable cognitive decline and eventual dementia. The rationale for early diagnosis in symptomatic AD is equally applicable in preclinical AD-to minimize risk, maximize quality of life, and ensure optimal planning and communication. Family members and other sources of support will likely be essential to the goals of this new model of care for preclinical AD patients and trials must instruct this clinical practice.

  2. Study of cerebrovascular diseases and SPECT with 99mTc HMPAO

    International Nuclear Information System (INIS)

    Collazo de la Maza, A.; Borron Molinos, M.; Barroso, E.

    1997-01-01

    Thirty eight patients with Cerebrovascular disease, that had suffered a Thrombotic brain infraction, demonstrated by Computed electroencephalogram or Brain Mapping (BM) and Computerized Tomography (CT) were investigated with '99' '9' 'm' Tc HM-PAO brain SPECT. Their ages ranged from 37 to 73 years old, 18 males and 20 female. Some of them were followed up with these diagnostic methods. The acquisition and processing of the SPECT studies were donw with a SOPHY DS7 Gamma Camera. The results showed that the global diagnostic sensibility of the SPECT was 79%. The sensibility of SPECT in the Acute stage was 75 %, CT 57% and BM 92%. In Steady stage we found a high positivity of SPECT with 83 %, Ct 66% and BM 66%. In the Recuperation Stage SPECT was 77%, CT 66% and 45%. Some phenomenon like the Luxury Perfusion and Diaschisis were studied and it is possible to found some prognostic relation

  3. Molecular imaging agents for SPECT (and SPECT/CT)

    International Nuclear Information System (INIS)

    Gnanasegaran, Gopinath; Ballinger, James R.

    2014-01-01

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  4. Molecular imaging agents for SPECT (and SPECT/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Gnanasegaran, Gopinath [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); Ballinger, James R. [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom)

    2014-05-15

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  5. Study of regional cerebral blood flow SPECT imaging for sudden sensorineural deafness

    International Nuclear Information System (INIS)

    Xie Changhui; Kui Xixiao; Xiong Qibin; Wen Hui; Xie Jiabiao

    1998-01-01

    Purpose: To study the clinical value of regional cerebral blood flow (rCBF) SPECT imaging for sudden sensorineural deafness (SSD). Methods: 10 normal persons, 19 conductive deafness and 31 SSD patients were examined by rCBF SPECT imaging, and compared with X CT at the same time. All SSD patients were followed up for 6∼12 months with repeated rCBF SPECT imaging. Results: 1) The radioactivity of diseased and normal horizontal temporal gyrus ratio (T/NT) in SSD patients was the lowest among three groups (P < 0.01). 2) The sensitivity (80.6%) and accurate rate (88.3%) of rCBF SPECT imaging in SSD patients were much higher than those of CT (3.2% and 50%, P < 0.01). 3) There was a significant correlation between degree of deafness and T/NT in SSD patients. 4) Good prognosis of SSD patients with normal rCBF SPECT was found. 5) The rCBF SPECT had close concordance between rCBF SPECT imaging and clinical prognosis (84.6%). Conclusions: rCBF SPECT imaging was superior to X CT in diagnosis of SSD and played an important clinical role

  6. Perspective: Recommendations for benchmarking pre-clinical studies of nanomedicines

    Science.gov (United States)

    Dawidczyk, Charlene M.; Russell, Luisa M.; Searson, Peter C.

    2015-01-01

    Nanoparticle-based delivery systems provide new opportunities to overcome the limitations associated with traditional small molecule drug therapy for cancer, and to achieve both therapeutic and diagnostic functions in the same platform. Pre-clinical trials are generally designed to assess therapeutic potential and not to optimize the design of the delivery platform. Consequently, progress in developing design rules for cancer nanomedicines has been slow, hindering progress in the field. Despite the large number of pre-clinical trials, several factors restrict comparison and benchmarking of different platforms, including variability in experimental design, reporting of results, and the lack of quantitative data. To solve this problem, we review the variables involved in the design of pre-clinical trials and propose a protocol for benchmarking that we recommend be included in in vivo pre-clinical studies of drug delivery platforms for cancer therapy. This strategy will contribute to building the scientific knowledge base that enables development of design rules and accelerates the translation of new technologies. PMID:26249177

  7. USHERING IN THE STUDY AND TREATMENT OF PRECLINICAL ALZHEIMER DISEASE

    Science.gov (United States)

    Langbaum, Jessica B.S.; Fleisher, Adam S.; Chen, Kewei; Ayutyanont, Napatkamon; Lopera, Francisco; Quiroz, Yakeel T.; Caselli, Richard J.; Tariot, Pierre N.; Reiman, Eric M.

    2014-01-01

    Researchers have begun to characterize the subtle biological and cognitive processes that precede the clinical onset of Alzheimer disease (AD), and to set the stage for accelerated evaluation of experimental treatments to delay the onset, reduce the risk of or completely prevent clinical decline. Here, we provide an overview of the experimental strategies, and brain imaging and cerebrospinal fluid biomarker measures that are used in early detection and tracking of AD, highlighting at-risk individuals who could be suitable for preclinical monitoring. We discuss how these advances have contributed to reconceptualization of AD as a sequence of biological changes that occur during progression from preclinical AD, to mild cognitive impairment and finally dementia, and we review recently proposed research criteria for preclinical AD. Advances in the study of preclinical AD have driven the recognition that efficacy of at least some AD therapies may depend on initiation of treatment before clinical manifestation of disease, leading to a new era of AD prevention research. PMID:23752908

  8. Pre-evaluation study in SPECT images using a phantom

    International Nuclear Information System (INIS)

    Rebelo, Marina de Sa; Furuie, Sergio Shiguemi; Abe, Rubens; Moura, Lincoln

    1996-01-01

    An alternative solution for the reconstruction of SPECT images using a Poisson Noise Model is presented. The proposed algorithm was applied on a real phantom and compared to the standard clinical procedures. Results have shown that the proposed method improves the quality of the SPECT images

  9. Study on SPECT image for children with cerebral infarction

    International Nuclear Information System (INIS)

    Xie Wenhuang; Xie Zhichun; Chen Yucai; Lin Haoxue; Zheng Aidong; Xie Hui

    1998-01-01

    To explore the diagnostic value of SPECT image for children with cerebral infarction (CCI), comparative research was made on 26 cases undergoing regional cerebral perfusion (rCP) image between SPECT imaging and CT scanning. The results showed that the rCP in the infarct and its distant area was decreased. The positive rate of SPECT and CT were 92.3% (24/26) and 84.5% (22/26) respectively. The difference was not significant (P = 0.67, P>0.05). But, the positive rate of SPECT image 2 days after onset in 9 CCI was 100% (9/9), significantly higher than 55.6% (5/9) in CT scanning (P = 0.04, P<0.05). These findings suggested that the SPECT imaging is a sensitive method for the early diagnosis of CCI, and also helpful for observation of the therapeutic effect and evaluation of the prognosis

  10. Radioiodination of central nerves system dopamine D2 receptor imaging agent. IBZM preparation and preclinical study

    International Nuclear Information System (INIS)

    Lin Yansong; Lin Xiangtong; Hu Mingyang; Pan Shangren; Wang Bocheng

    1996-01-01

    To study preparation of central nerves system dopamine D2 imaging agent 131 I-IBZM and its preclinical investigation, peracetic acid was used as the oxidant for preparing radioiodinated 125 I-IBZM and 131 I-IBZM, D2 binding properties of IBZM were examined by in vitro binding saturation analysis, rat whole body and regional brain biodistribution, rat brain autoradiography and rabbit SPECT static imaging, etc. The results are: 1. The radiolabelling yields of 125 I-IBZM and 131 I-IBZM were 84.18% +- 3.06% and 78.50% +- 3.47%. The radiochemical purity were over 95% after being isolated by HPLC; and were over 90% after being isolated by organic extraction. 2. Scatchard plot of D2 receptor saturation binding analysis showed: K d = 0.53 +- 0.06 nmol/L, B max = 466.45 +- 45.88 fmol/mg protein. 3. The rat brain autoradiography and analysis showed that there was high 125 I-IBZM uptake in striatal area 2 hr after injection, the striatal/cerebellum ratio was 6.22 +- 0.48; the high 125 -IBZM uptake can be blocked by haloperidol--a special dopamine D2 receptor antagonist. 4. 131 I-IBZM rat biodistribution and rabbit SPECT planar imaging showed good initial brain uptake and retention, the initial uptake of rat brain was 1.893 +- 0.147% ID/g at 2 min and 1.044 +- 0.135% ID/g at 60 min. The results showed that the radioiodinated IBZM had high affinity, saturation and specificity to rat's and rabbit's central nerves system dopamine D2 receptors

  11. Radioiodination of central nerves system dopamine D2 receptor imaging agent. IBZM preparation and preclinical study

    Energy Technology Data Exchange (ETDEWEB)

    Yansong, Lin; Xiangtong, Lin; Mingyang, Hu; Shangren, Pan; Bocheng, Wang [Huashan Hospital of Shanghai Medical Univ., Shanghai (China)

    1996-11-01

    To study preparation of central nerves system dopamine D2 imaging agent {sup 131}I-IBZM and its preclinical investigation, peracetic acid was used as the oxidant for preparing radioiodinated {sup 125}I-IBZM and {sup 131}I-IBZM, D2 binding properties of IBZM were examined by in vitro binding saturation analysis, rat whole body and regional brain biodistribution, rat brain autoradiography and rabbit SPECT static imaging, etc. The results are: 1. The radiolabelling yields of {sup 125}I-IBZM and {sup 131}I-IBZM were 84.18% +- 3.06% and 78.50% +- 3.47%. The radiochemical purity were over 95% after being isolated by HPLC; and were over 90% after being isolated by organic extraction. 2. Scatchard plot of D2 receptor saturation binding analysis showed: K{sub d} = 0.53 +- 0.06 nmol/L, B{sub max} = 466.45 +- 45.88 fmol/mg protein. 3. The rat brain autoradiography and analysis showed that there was high {sup 125}I-IBZM uptake in striatal area 2 hr after injection, the striatal/cerebellum ratio was 6.22 +- 0.48; the high {sup 125}-IBZM uptake can be blocked by haloperidol--a special dopamine D2 receptor antagonist. 4. {sup 131}I-IBZM rat biodistribution and rabbit SPECT planar imaging showed good initial brain uptake and retention, the initial uptake of rat brain was 1.893 +- 0.147% ID/g at 2 min and 1.044 +- 0.135% ID/g at 60 min. The results showed that the radioiodinated IBZM had high affinity, saturation and specificity to rat`s and rabbit`s central nerves system dopamine D2 receptors.

  12. Preclinical studies on gadolinium neutron capture therapy

    International Nuclear Information System (INIS)

    Akine, Yasuyuki

    1994-01-01

    Gadolinium neutron capture therapy is based on radiations (photons and electrons) produced in the tumor by a nuclear reaction between gadolinium and lower-energy neutrons. Studies with Chinese hamster cells have shown that the radiation effect resulting from gadolinium neutron capture reactions is mostly of low LET and that released electrons are the significant component in the over-all dose. Biological dosimetry revealed that the dose does not seem to increase in proportion to the gadolinium concentration, leading to a conclusion that there is a range of gadolinium concentrations most efficient for gadolinium neutron capture therapy. The in vivo studies with transplantable tumors in mice and rabbits have revealed that close contact between gadolinium and the cell is not necessarily required for cell inactivation and that gadolinium delivery selective to tumors is crucial. The results show that the potential of gadolinium neutron capture therapy as a therapeutic modality appears very promising. (author)

  13. Recent Developments in Instrumentation for Pre-Clinical Imaging Studies

    International Nuclear Information System (INIS)

    Meikle, S.R.

    2002-01-01

    Full text: Recent advances in imaging instrumentation have led to a variety of tomograph designs for dedicated pre clinical imaging of laboratory animals. These advances make it possible to image and quantify the kinetics of radiolabelled pharmaceuticals in a wide range of animal models from rodents to non-human primates. Applications include evaluation of promising new radiopharmaceuticals, study of the molecular origins of human disease and evaluation of new forms of therapy. These applications and advances in instrumentation are equally applicable to positron emitters and single photon emitters. This paper provides an overview of recent advances which have led to the current state-of-the-art in pre clinical imaging. The common inorganic scintillators that have been used for SPECT and PET, including some of the promising materials recently studied. The current crystal of choice for SPECT imaging is NaI(Tl) because of its high light output and density which make it well suited to imaging photons in the 100-200 keV range. However, NaI(Tl) has the disadvantage that it must be hermetically sealed to prevent absorption of moisture from the environment. Therefore, investigators have explored a number of alternative inorganic crystals, including CsI(Tl) and cerium-doped yttrium aluminium perovskite (YAP), as well as solid state detectors such as cadmium zinc telluride (CZT). Many of the crystals used in SPECT have also been tried for PET, including NaI(Tl) and YAP. However these crystals have lower stopping power than BGO and NaI(Tl) is also relatively slow. A very promising scintillator for PET is cerium-doped lutetium oxyorthosilicate (LSO) (1) which has similar stopping power to BGO and relatively high light output and fast decay. The first PET scanner to use LSO was the UCLA animal scanner, microPET, which also makes use of a number of other new technologies and unique design features. Recently, improvements in multi-anode and crossed wire position sensitive

  14. [sup 99m]Tc-ECD SPECT study in dementia and aphasia

    Energy Technology Data Exchange (ETDEWEB)

    Kuwabara, Yasuo; Ichiya, Yuichi; Otsuka, Makoto; Sasaki, Masayuki; Akashi, Yuko; Fukumura, Toshimitsu; Yoshida, Tsuyoshi; Masuda, Kouji; Ichimiya, Atsushi (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1993-09-01

    We studied clinical significance of [sup 99m]Tc-L,L,-ethyl cysteine dimer ([sup 99m]Tc-ECD) SPECT study in dementia and aphasia, and compared it with [sup 99m]Tc-HMPAO SPECT study. The subjects consisted of 13 patients, including 10 patients with dementia and 3 patients with aphasia. Hypoperfusion areas were detected in 5 out of 10 patients with dementia and 2 out of 3 patients with aphasia in [sup 99m]Tc-ECD SPECT, and in 4 out of 10 patients with dementia and all of 3 patients with aphasia in [sup 99m]Tc-HMPAO SPECT. The count rate ratios in [sup 99m]Tc-ECD and [sup 99m]Tc-HMPAO SPECT were correlated well with each other, and the contrast of the [sup 99m]Tc-ECD SPECT image was equivalent or slightly higher as compared with [sup 99m]Tc-HMPAO. Therefore, [sup 99m]Tc-ECD SPECT study was considered to be useful for the evaluation of cerebral perfusion in dementia and aphasia. (author).

  15. 99mTc-ECD SPECT study in dementia and aphasia

    International Nuclear Information System (INIS)

    Kuwabara, Yasuo; Ichiya, Yuichi; Otsuka, Makoto; Sasaki, Masayuki; Akashi, Yuko; Fukumura, Toshimitsu; Yoshida, Tsuyoshi; Masuda, Kouji; Ichimiya, Atsushi

    1993-01-01

    We studied clinical significance of 99m Tc-L,L,-ethyl cysteine dimer ( 99m Tc-ECD) SPECT study in dementia and aphasia, and compared it with 99m Tc-HMPAO SPECT study. The subjects consisted of 13 patients, including 10 patients with dementia and 3 patients with aphasia. Hypoperfusion areas were detected in 5 out of 10 patients with dementia and 2 out of 3 patients with aphasia in 99m Tc-ECD SPECT, and in 4 out of 10 patients with dementia and all of 3 patients with aphasia in 99m Tc-HMPAO SPECT. The count rate ratios in 99m Tc-ECD and 99m Tc-HMPAO SPECT were correlated well with each other, and the contrast of the 99m Tc-ECD SPECT image was equivalent or slightly higher as compared with 99m Tc-HMPAO. Therefore, 99m Tc-ECD SPECT study was considered to be useful for the evaluation of cerebral perfusion in dementia and aphasia. (author)

  16. Ibrutinib brain distribution: a preclinical study.

    Science.gov (United States)

    Goldwirt, Lauriane; Beccaria, Kevin; Ple, Alain; Sauvageon, Hélène; Mourah, Samia

    2018-04-01

    Central nervous system (CNS) dissemination occurs in 4.1% of mantle cell lymphoma (MCL) patients and clinically significant CNS involvement in chronic lymphocytic leukemia (CLL) patients reaches 4%. Ibrutinib, an orally administered Bruton's tyrosine kinase (BTK) inhibitor, has shown substantial activity in CLL or MCL patients with CNS localization, and in primary central nervous system lymphoma (PCNSL). The drug efficacy to treat primary or secondary CNS impairments relies on its brain distribution through the blood-brain barrier (BBB), the aim of the present work was to study the brain distribution of ibrutinib using an in vivo mice model. Brain and plasma pharmacokinetics of ibrutinib were assessed in a healthy Swiss mice model. Brain accumulation of ibrutinib was evaluated through an escalation single-dose study and a multiple-dose study in whole brain and in its specific anatomic structures. Ibrutinib plasma and brain quantification was performed using a validated liquid-chromatography mass tandem spectrometry method. Maximal concentration of ibrutinib in plasma and brain were close thus showing that ibrutinib rapidly crosses the BBB in 0.29 h (0.2-0.32 h) [median (min-max)]. Ibrutinib brain exposure was also correlated to the dose, and correlated to plasma exposure. AUC 0-t brain to AUC 0-t plasma ratio average for ibrutinib was found to reach 0.7 and ibrutinib accumulates in the ventricle area. The high level of ibrutinib brain distribution supports the clinical efficacy of this drug in CNS localization of MCL, CLL or PCNSL.

  17. Motor activation SPECT for the neurosurgical diseases. Examination protocol and basic study

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Hiroshi; Kawaguchi, Shoichiro; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    1999-07-01

    We examined and analyzed the region activated by the unilateral finger opposition task using motor activation single photon emission computed tomography (M-SPECT). M-SPECT studies were carried out on 11 cases, all of whom were normal volunteers (mean age: 49.4 years), none of whom showed any abnormal findings on magnetic resonance images (MRIs) or any neurological abnormalities. The SPECT images for each case were superimposed on the MRIs using Image Fusion Software. The result of the M-SPECT study was expressed as positive or negative. The cases with a marked increase of blood flow in the sensori-motor cortex during the finger opposition task were categorized as positive, and those cases showing no marked increase of blood flow were categorized as negative. Among 11 patients, 10 cases (90.9%) showed positive M-SPECT findings, and the eleventh case showed negative M-SPECT findings. The asymmetry index (AI) was calculated on the sensorio-motor cortex in the SPECT images before and after motor activation, with the 10 cases with positive M-SPECT having an AI before motor activation of 0.99{+-}0.06 (mean{+-}standard deviation) and an AI after motor activation of 1.14{+-}0.07. This change was statistically significant (p<0.05). In the single case categorized as negative, the AI before motor activation was 1.04, and the AI after motor activation was 1.01. There was no significant difference of AI values between the resting and motor activation stages. The positive M-SPECT was seen in 90.9% of the normal volunteer series using a visual inspection method. In these cases, the blood flow in the sensorio-motor cortex significantly increased after application of the finger opposition task using the semi-quantitative method. (author)

  18. A SPECT study in internal carotid artery occlusion: Discrepancies between flow image and neurologic deficits

    International Nuclear Information System (INIS)

    Moriwaki, H.; Hougaku, H.; Matsuda, I.; Kusunoki, M.; Shirai, J.

    1989-01-01

    A SPECT (single photon emission computed tomography) study in internal carotid artery (ICA) occlusion was performed in 6 patients. The validity of iodoamphetamine (IMP) SPECT study in the evaluation of cerebral blood flow (CBF) or neurologic function is still controversial. In this study, the authors showed several cases in whom SPECT images of brain were not compatible with their neurologic deficits. In 2 typical cases, a large low-density area was observed in the non-dominant hemisphere in computed tomography (CT) scan, but no apparent motor-sensory deficits in left limbs were present. In these patients, SPECT study also revealed flow reduction in the affected side of the brain. So there was a possibility that an IMP brain image could not always reflect CBF, which maintains neurologic function of the brain

  19. Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols

    International Nuclear Information System (INIS)

    Verger, Antoine; Karcher, Gilles; Djaballah, Wassila; Fourquet, Nicolas; Rouzet, Francois; Le Guludec, Dominique; Koehl, Gregoire; Roch, Veronique; Imbert, Laetitia; Poussier, Sylvain; Fay, Renaud; Marie, Pierre-Yves

    2013-01-01

    The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity. The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving 201 Tl (n = 120) or 99m Tc-sestamibi injected at low dose at stress ( 99m Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ( 99m Tc-High; rest/stress 1-day or 2-day protocol; n = 46). Each Anger SPECT scan was followed by a high-speed CZT SPECT scan (2 to 4 min). Agreement rates between CZT and Anger SPECT were good irrespective of the study protocol (for abnormal SPECT, 201 Tl 92 %, 99m Tc-Low 86 %, 99m Tc-High 98 %), although quality scores were much higher for CZT SPECT with all study protocols. Overall correlations were high for the extent of myocardial infarction (r = 0.80) and a little lower for ischaemic areas (r = 0.72), the latter being larger on Anger SPECT (p 201 Tl or 99m Tc-Low group and in whom stress myocardial counts were particularly low with Anger SPECT (228 ± 101 kcounts) and dramatically enhanced with CZT SPECT (+279 ± 251 %). Concordance between the results of CZT and Anger SPECT is good regardless of study protocol and especially when excluding obese patients who have low-count Anger SPECT and for whom myocardial counts are dramatically enhanced on CZT SPECT. (orig.)

  20. Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols

    Energy Technology Data Exchange (ETDEWEB)

    Verger, Antoine; Karcher, Gilles [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Djaballah, Wassila [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); INSERM U947, Nancy (France); Fourquet, Nicolas [Clinique Pasteur, Toulouse (France); Rouzet, Francois; Le Guludec, Dominique [AP-HP, Hopital Bichat, Department of Nuclear Medicine, Paris (France); INSERM U 773 Inserm and Denis Diderot University, Paris (France); Koehl, Gregoire; Roch, Veronique [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Imbert, Laetitia [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Centre Alexis Vautrin, Department of Radiotherapy, Vandoeuvre (France); Poussier, Sylvain [INSERM U947, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); Fay, Renaud [INSERM, Centre d' Investigation Clinique CIC-P 9501, Nancy (France); Marie, Pierre-Yves [CHU-Nancy, Department of Nuclear Medicine, Nancy (France); Nancyclotep Experimental Imaging Platform, Nancy (France); INSERM U961, Nancy (France); Hopital de Brabois, CHU-Nancy, Medecine Nucleaire, Vandoeuvre-les-Nancy (France)

    2013-03-15

    The results of stress myocardial perfusion SPECT could be enhanced by new cadmium-zinc-telluride (CZT) cameras, although differences compared to the results with conventional Anger cameras remain poorly known for most study protocols. This study was aimed at comparing the results of CZT and Anger SPECT according to various study protocols while taking into account the influence of obesity. The study population, which was from three different institutions equipped with identical CZT cameras, comprised 276 patients referred for study using protocols involving {sup 201}Tl (n = 120) or {sup 99m}Tc-sestamibi injected at low dose at stress ({sup 99m}Tc-Low; stress/rest 1-day protocol; n = 110) or at high dose at stress ({sup 99m}Tc-High; rest/stress 1-day or 2-day protocol; n = 46). Each Anger SPECT scan was followed by a high-speed CZT SPECT scan (2 to 4 min). Agreement rates between CZT and Anger SPECT were good irrespective of the study protocol (for abnormal SPECT, {sup 201}Tl 92 %, {sup 99m}Tc-Low 86 %, {sup 99m}Tc-High 98 %), although quality scores were much higher for CZT SPECT with all study protocols. Overall correlations were high for the extent of myocardial infarction (r = 0.80) and a little lower for ischaemic areas (r = 0.72), the latter being larger on Anger SPECT (p < 0.001). This larger extent was mainly observed in 50 obese patients who were in the {sup 201}Tl or {sup 99m}Tc-Low group and in whom stress myocardial counts were particularly low with Anger SPECT (228 {+-} 101 kcounts) and dramatically enhanced with CZT SPECT (+279 {+-} 251 %). Concordance between the results of CZT and Anger SPECT is good regardless of study protocol and especially when excluding obese patients who have low-count Anger SPECT and for whom myocardial counts are dramatically enhanced on CZT SPECT. (orig.)

  1. Episodic aphasia associated with tumor active multiple sclerosis: a correlative SPECT study utilising image fusion

    International Nuclear Information System (INIS)

    Roff, G.; Campbell, A.; Lawn, N.; Henderson, A.; McCarthy, M.; Lenzo, N.

    2003-01-01

    Full text: Cerebral perfusion imaging is a common technique to assess cerebral perfusion and metabolism. It can complement anatomical imaging in assessing a number of neurological conditions. At times it can better define the clinical manifestations of a disease process than anatomical imaging alone. We present a clinical case whereby cerebral SPECT imaging helped define the physiological reason for intermittent aphasia in a patient with tumor active multiple sclerotic white matter plaques. Cerebral SPECT studies were performed during a period of aphasia and when the patient had recovered. We utilised subtraction analyses and image fusion techniques to better define the changes seen on SPECT. We discuss the neuroanatomical relationship of aphasia and the automatic fusion technique that allows accurate co-registration of the MRI and SPECT data. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  2. Risk assessment after coronary angioplasty with SPECT myocardial perfusion studies

    International Nuclear Information System (INIS)

    Camilletti, Jorge A.; Erriest, Juan; Mele, Anibal A.

    2007-01-01

    The chest pain can be use for stratifying the risk of the patients after coronary angioplasty. Nevertheless this strategy has shown to have a low accuracy in the detection of restenosis and myocardial ischemia. Aims: To establish the usefulness of the SPECT studies in the risk stratification after the coronary angioplasty. Evaluate the incidence of silent ischemia or symptomatic, and its impact on the prognosis. Method: There were included 107 patients (p) submitted to a gated SPECT between the year of the coronary angioplasty. The analysis of the images was performed according to different scores (SSS, SRS, SDS). These data was correlated with the symptoms of the patients. We define group 1 (G1) as the asymptomatic without ischemia (n 59p), group 2 (G2) as silent ischemia (n = 28p) and group 3 (G3) as symptomatic with ischemia (n = 20p). A clinical follow-up was done in search of events (target vessel revascularization, unstable angina, AMI and death). Results: Significant differences were not observed in the clinical variables between the different groups. The SSS was lower in the G1 compare with G2 and G3 (p 0.0001) and was similar between the last two, p = NS (SSS: G1: 2.2 ± 4.9; G2: 7.6 ± 5.9; G3: 9.5 ± 6.8). The SDS was greater in G3 vs. G1 and G2, p = 0.0001, and greater in G2 vs. G1, p = 0.0001 (SDS: G1: 0; G2: 4.8 ± 3.5; G3: 7.2 ± 6.5). No differences where observed in the SRS between the three groups. In the follow-up the total percentage of events was lesser when compare the G1 with the G2 and G3 (G1: 3.3%; G2 and G3: 18.7%; p 0.02). The percentage of annual events of the G3 symptomatic with ischemia (11.03%) and G2 silent ischemia (4.04%) did not present differences (p 0.7). When the events of the G2 (4.04%) were compared with the G1 (1.24%) we observed a trend to major frequency of events in the G2 (p = 0.6). Conclusions: The presence of myocardial ischemia after coronary angioplasty is a determinant of the prognosis. Nevertheless, the extension

  3. Melatonin and breast cancer: Evidences from preclinical and human studies.

    Science.gov (United States)

    Kubatka, Peter; Zubor, Pavol; Busselberg, Dietrich; Kwon, Taeg Kyu; Adamek, Mariusz; Petrovic, Daniel; Opatrilova, Radka; Gazdikova, Katarina; Caprnda, Martin; Rodrigo, Luis; Danko, Jan; Kruzliak, Peter

    2018-02-01

    The breast cancer affects women with high mortality and morbidity worldwide. The risk is highest in the most developed world but also is markedly rising in the developing countries. It is well documented that melatonin has a significant anti-tumor activities demonstrated on various cancer types in a plethora of preclinical studies. In breast cancer, melatonin is capable to disrupt estrogen-dependent cell signaling, resulting in a reduction of estrogen-stimulated cells, moreover, it's obvious neuro-immunomodulatory effect in organism was described. Several prospective studies have demonstrated the inverse correlation between melatonin metabolites and the risk of breast cancer. This correlation was confirmed by observational studies that found lower melatonin levels in breast cancer patients. Moreover, clinical studies have showed that circadian disruption of melatonin synthesis, specifically night shift work, is linked to increased breast cancer risk. In this regard, proper light/dark exposure with more selective use of light at night along with oral supplementation of melatonin may have benefits for high-risk women. The results of current preclinical studies, the mechanism of action, and clinical efficacy of melatonin in breast cancer are reviewed in this paper. Melatonin alone or in combined administration seems to be appropriate drug for the treatment of early stages of breast cancer with documented low toxicity over a wide range of doses. These and other issues are also discussed. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. The effect of education on rCBF changes in Alzheimer's disease: a longitudinal SPECT study

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Sato, Tomohiko; Shimizu, Soichiro; Kanetaka, Hidekazu; Iwamoto, Toshihiko; Koizumi, Kiyoshi

    2008-01-01

    To determine the relationship of differing levels of education on regional cerebral blood flow (rCBF) in patients with Alzheimer's disease (AD). Fifty-three patients with AD followed-up for an average of 36 months were divided into the high-educated group (HE, ≥12 years of schooling) and low-educated group (LE, 123 I]-iodoamphetamine and the SPECT data were analyzed by 3D-stereotactic surface projections. At initial evaluation, the HE group had greater rCBF deficits in the parietotemporal regions than did the LE group, even though both groups had comparable MMSE and FAST scores. When compared with initial SPECT, follow-up SPECT showed a significant rCBF reduction in widespread regions, including the frontal, parietal, temporal, and limbic lobes of the HE group, while it a significant rCBF reduction in scattered and small regions of the parietotemporal, cingulate, and occipital areas of the LE group, as the HE group had faster cognitive and functional decline than the LE group. The HE group showed lower rCBF at initial SPECT than the LE group, suggesting more advanced AD pathology. As a result, the HE group demonstrated a more extensive and severe reduction of rCBF on follow-up SPECT in association with faster cognitive and functional decline than the LE group. Our SPECT study provides stronger support for the cognitive reserve effects of education in AD. (orig.)

  5. Perfusion study in the pulmonary hilar region by SPECT

    International Nuclear Information System (INIS)

    Satoh, Katashi; Tanabe, Masatada; Kawase, Yoshiro

    1990-01-01

    Alveoli in the hilar region comprise the peripheral area containing daughter branches from subsegmental or one more divisional peripheral bronchi. Pulmonary perfusion in hilar region was examined by SPECT (single photon emission CT) in ten normal volunteers. ROI (region of interest) in the axial images were set in the hilar region, the upper, middle and lower lung fields with 10.8 mm thickness. Counts/one pixel (C/P) were calculated in these ROI. There was a tendency of C/P increase from upper to lower lung field. And there were no significant differences in C/P increase between hilar region and other axial fields. In the chronic obstructive pulmonary diseases, however, ventilation studies in the previous reports using Xe dynamic CT or PET (positron emission tomography) showed differences between outer region and hilar region. This method will be expected to evaluate the pulmonary perfusion not only in the whole lung but in different lung areas, including the hilar region in the chronic obstructive pulmonary diseases. (author)

  6. The SPECT tracer [123I]ADAM binds selectively to serotonin transporters: a double-blind, placebo-controlled study in healthy young men

    International Nuclear Information System (INIS)

    Giessen, Elsmarieke van de; Booij, Jan

    2010-01-01

    The tracer 123 I-2-([2-({dimethylamino}methyl)phenyl]thio)-5-iodophenylamine ([ 123 I]ADAM) has been developed to image serotonin transporters (SERTs) with SPECT. Preclinical studies have shown that [ 123 I]ADAM binds selectively to SERTs. Moreover, initial human studies have shown that [ 123 I]ADAM binding could be blocked by selective serotonin reuptake inhibitors (SSRIs). However, in humans it has not been proven that [ 123 I]ADAM binds selectively to SERTs. We examined the in vivo availability of SERTs in 12 healthy young volunteers 5 h after bolus injection of [ 123 I]ADAM. To evaluate the selectivity of binding, four participants were pretreated (double-blinded design) with placebo, four with paroxetine (20 mg) and four with the dopamine/norepinephrine blocker methylphenidate (20 mg). SPECT studies were performed on a brain-dedicated system (Neurofocus), and the SPECT images were coregistered with individual MR scans of the brain. ADAM binding in SERT-rich brain areas and cerebellar cortex (representing non-specific binding) was assessed by drawing regions of interest (ROIs) on the individual MR images. Specific to non-specific ratios were used as the outcome measure. We found that specific to non-specific ratios were statistically significantly lower in paroxetine-pretreated participants than in placebo- or methylphenidate-pretreated participants. No such difference was found between groups pretreated with placebo or methylphenidate. Our preliminary findings suggest that [ 123 I]ADAM binds selectively to SERTs in human brain. (orig.)

  7. The preclinical pharmacological study of dopamine transporter imaging agnet (99mTc)trodat-1

    International Nuclear Information System (INIS)

    Fang, P.; Wan, W.; Wu, C.; Liu, Z.; Wang, T.; Chen, S.; Chen, Z.; Zhou, X.

    2000-01-01

    To develop 99m Tc labeled dopamine transporter (DAT) imaging agent 99m Tc-TRODAT-1 (TRODAT-1:2 β-[[N,N'-bis(2-mercaptoethyl)ethylenediamino]methl], 3 β-(4-chlorophenyl)tropane], used in SPECT, for evaluating changes of DAT in patients with Parkinson's disease(PD). Using Stannous as reducing agent, and the present of Na-glucoheptonate, 99m Tc-TRODAT-1 was successfully prepared. Preclinical pharmacological studies have been performed in rats. C57BL mice, normal and PD model monkeys and volunteers. Radiochemical purity of 99m Tc-TRODAT-1 was over 90%, and stable for 6 hours. The specific uptake in striatum was significantly diminished from 3.45 to 0.12 at 3 h by pretreated rats with a dose of competing DAT ligand β-CIT (1 mg/kg). Autoradiographic images in C57BL mice shows that the specific uptake has a good linear relationship with the quantity of neural-toxin (MPTP) which was given to the animals (r=0.9792). Images of normal monkey's brain exhibited excellent localization in basal ganglia region, where dopamine neurons were concentrated, and the ratios of ST/CB were 1.56-2.0. In hemiparkinsonian model monkeys, the ratio of normal ST/CB and lesioned ST/CB were 1.56 and 0.94, respectively. Brain image studies in volunteers indicated that uptake and retention in the basal ganglia, the ratio of normal striatal to lesioned one was 1.15 measured by SPECT imaging at 2 h. The result of images was consistent with the clinical symptoms. Above-mentioned results showed that 99m Tc-TRODAT-1 can be accumulated in the striatal area, where DAT are concentrated, high quality images were obtained. It is suggested that 99m Tc-TRODAT-1 might turn to be a safe and effective tracer for monitoring the change in DAT associated with various neurodegenerative diseases

  8. Cerebral fat embolism studied with MRI and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, E. (Dept. of Neurology, Hacettepe Univ. School of Medicine, Ankara (Turkey)); Namer, I.J. (Inst. of Biophysics, Faculty of Medicine, Louis Pasteur Univ., Strasbourg (France)); Saribas, O. (Dept. of Neurology, Hacettepe Univ. School of Medicine, Ankara (Turkey)); Aras, T. (Dept. of Nuclear Medicine, Hacettepe Univ. School of Medicine Ankara (Turkey)); Tan, E. (Dept. of Neurology, Hacettepe Univ. School of Medicine, Ankara (Turkey)); Bekdik, C. (Dept. of Nuclear Medicine, Hacettepe Univ. School of Medicine Ankara (Turkey)); Zileli, T. (Dept. of Neurology, Hacettepe Univ. School of Medicine, Ankara (Turkey))

    1993-03-01

    In a patient with fat embolism to the brain CT showed no abnormality. MRI performed after recovery from coma, when the patient had aphasia and quadriparesis, demonstrated multiple high signal abnormalities in the white matter on both T1- and T2-weighted images. HMPAO-SPECT showed left-sided hypoperfusion which resolved in parallel with clinical improvement 1 month later. (orig.)

  9. A Comparative Study of SPECT, q-EEG and CT in Patients with Mild, Acute Head Trauma

    International Nuclear Information System (INIS)

    Lee, Suk Ho; Kim, Jin Seok; Moon, Hee Seung

    1993-01-01

    Functional cerebral impairments have been verified objectively by brain SPECT and q-EEG (quantitative electroencephalography). Microcerebral circulatory defects without anatomical changes cannot be detected by the brain CT or MRI. Brain SPECT using 99m Tc-HMPAO (Hexamethyl propyleneamine oxime) as a key radioisotope may be accepted as the useful method for identifying functional cerebral impairments. We studied 25 patients with mild head trauma to define whether the SPECT was helpful in detecting cerebral impairment. The SPECT was positive in 23 patients out of 25, q-EEG positive in 16 patients and brain CT was positive in 3 cases. SPECT and q-EEG were more sensitive than CT. SPECT would be more useful method than brain CT to investigate cerebral function after head injury

  10. Preliminary study for small animal preclinical hadrontherapy facility

    Energy Technology Data Exchange (ETDEWEB)

    Russo, G. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Pisciotta, P., E-mail: pietro.pisciotta@ibfm.cnr.it [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy); Cirrone, G.A.P.; Romano, F. [National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy); Cammarata, F.; Marchese, V.; Forte, G.I.; Lamia, D.; Minafra, L.; Bravatá, V. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Acquaviva, R. [University of Catania, Catania (Italy); Gilardi, M.C. [Institute of Molecular Bioimaging and Physiology, IBFM CNR-LATO, Cefalú (Italy); Cuttone, G. [National Institute for Nuclear Physics, Laboratori Nazionali del Sud, INFN-LNS, Catania (Italy)

    2017-02-21

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  11. Preliminary study for small animal preclinical hadrontherapy facility

    Science.gov (United States)

    Russo, G.; Pisciotta, P.; Cirrone, G. A. P.; Romano, F.; Cammarata, F.; Marchese, V.; Forte, G. I.; Lamia, D.; Minafra, L.; Bravatá, V.; Acquaviva, R.; Gilardi, M. C.; Cuttone, G.

    2017-02-01

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  12. Preliminary study for small animal preclinical hadrontherapy facility

    International Nuclear Information System (INIS)

    Russo, G.; Pisciotta, P.; Cirrone, G.A.P.; Romano, F.; Cammarata, F.; Marchese, V.; Forte, G.I.; Lamia, D.; Minafra, L.; Bravatá, V.; Acquaviva, R.; Gilardi, M.C.; Cuttone, G.

    2017-01-01

    Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and

  13. Preclinical and clinical safety studies on DNA vaccines.

    NARCIS (Netherlands)

    Schalk, Johanna A C; Mooi, Frits R; Berbers, Guy A M; Aerts, Leon A G J M van; Ovelgönne, Hans; Kimman, Tjeerd G

    2007-01-01

    DNA vaccines are based on the transfer of genetic material, encoding an antigen, to the cells of the vaccine recipient. Despite high expectations of DNA vaccines as a result of promising preclinical data their clinical utility remains unproven. However, much data is gathered in preclinical and

  14. Paradoxical motion of interventricular septum on Tc-99m MIBI gated SPECT study

    International Nuclear Information System (INIS)

    Ergun, E.L.; Erbas, B.; Beylergil, V.; Demirturk, O.S.; Pasaoglu, I.

    2004-01-01

    After uncomplicated cardiac surgery, abnormal motion of the interventricular septum is frequently observed. The interventricular septum has often been found to display dyskinetic, or paradoxical motion by echocardiographic studies. This study was undertaken to describe instances of paradoxical motion of interventricular septum on Tc-99m MIBI gated SPECT studies in patients after coronary artery by pass graft surgery. Tc-99m MIBI gated SPECT in conjunction with stress myocardial perfusion SPECT was performed in 18 patients who had history of cardiac bypass graft surgery. Paradoxical motion of the interventricular septum was defined visually from Tc-99m MIBI gated SPECT. Perfusion of the interventricular septum was examined from myocardial perfusion images in the same study. Paradoxical motion of the interventricular septum was observed in 4 patients (22%). The interventricular septum was normally perfused in all patients. It was concluded that paradoxical motion of the interventricular septum in patients who had a history of cardiac by-pass graft surgery is not an uncommon finding and it can be observed with gated SPECT. The exact mechanism of this phenomenon is not well-known. A normal perfusion in interventricular wall helps to discriminate this situation from a real abnormality. (author)

  15. Usefulness of MRI and SPECT studies in evaluating the lesion of aphasia

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Kobayashi, Yasutaka; Arai, Hisayuki; Hatano, Nobuyoshi; Yamaguchi, Katsuhiko; Katsunuma, Hideyo (Tokyo Medical Coll. (Japan))

    1990-06-01

    Since the introduction of CT scanning, correlations between neuropsychological findings and anatomical lesions have been studied. Anatomical studies by CT scans may, however, be misleading in delineating the extent of lesions in aphasia. We have carried out MRI (magnetic resonance imaging) and SPECT (single photon emission CT) examinations in 15 aphasic patients with cerebrovascular disease and discussed the usefulness of these studies. Compared to CT scan, MRI or SPECT studies were considered to be very useful in 8 of 15 patients. The useful points of these studies were: (1) easy detection of lesions with undetectable damages on CT, (2) demonstration of functional abnormalities in areas adjacent or distant from cerebrovascular lesions, and (3) precise definition of topographical abnormalities because of the three-dimensional imaging capability of MRI. As MRI or SPECT may define the actual extent of lesions and show areas of functional abnormality, these studies are useful and necessary in the assessment of lesions causing aphasia. (author).

  16. Usefulness of MRI and SPECT studies in evaluating the lesion of aphasia

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Kobayashi, Yasutaka; Arai, Hisayuki; Hatano, Nobuyoshi; Yamaguchi, Katsuhiko; Katsunuma, Hideyo

    1990-01-01

    Since the introduction of CT scanning, correlations between neuropsychological findings and anatomical lesions have been studied. Anatomical studies by CT scans may, however, be misleading in delineating the extent of lesions in aphasia. We have carried out MRI (magnetic resonance imaging) and SPECT (single photon emission CT) examinations in 15 aphasic patients with cerebrovascular disease and discussed the usefulness of these studies. Compared to CT scan, MRI or SPECT studies were considered to be very useful in 8 of 15 patients. The useful points of these studies were: 1) easy detection of lesions with undetectable damages on CT, 2) demonstration of functional abnormalities in areas adjacent or distant from cerebrovascular lesions, and 3) precise definition of topographical abnormalities because of the three-dimensional imaging capability of MRI. As MRI or SPECT may define the actual extent of lesions and show areas of functional abnormality, these studies are useful and necessary in the assessment of lesions causing aphasia. (author)

  17. Preclinical pharmacological studies of 99Tcm-TRODAT-1 as a dopamine transporter imaging agent

    International Nuclear Information System (INIS)

    Fang Ping; Wan Weixing; Liu Zhenguo; Wu Chunying; Chen Shengdi; Chen Zhengping; Zhou Xiang; Ji Shuren

    2001-01-01

    Objective: To develop a 99 Tc m labelled dopamine transporter (DAT) imaging agent, 99 Tc m -TRODAT-1 [TRODAT-1: 2β-([N,N'-bis(2-mercaptoethyl) ethylene diamino] methyl), 3β-(4-chlorophenyl) tropane], for evaluating the variation of DAT in patients with Parkinson's disease. Methods: 99 Tc m -TRODAT-1 was successfully prepared on a kit basis. Preclinical pharmacological studies were performed in rats, mice, rabbits, monkeys and a volunteer with diagnosed Parkinson disease (PD). Results: Radiochemical purity of 99 Tc m -TRODAT-1 was over 90%, and remained stable for 6 hours. The specific uptake in striatum was significantly diminished, from 3.45 to 0.12 at 2 h by pretreating rats with a dose of DAT competing ligand, β-CIT [1 mg/kg, 2β-carbomethoxy-3β-(4-iodophenyl) tropane]. Blood clearance kinetics was studied in rabbits, and the initial half-life was of 1.2 min, the elimination half-life was of 368 min. Images of normal monkey's brain exhibited an excellent accumulation in basal ganglia region, where dopamine neurons were concentrated. In hemi parkinsonism model monkeys, the ratio of normal ST/CB and lesioned ST/CB were 1.56 and 0.94, respectively. Brain imaging studies in volunteer indicated that uptake and retention in the basal ganglia, the ratio of normal striatal uptake to lesioned one's was 1.15 measured by SPECT imaging at 2 h. The result of imaging was conformable with his clinical symptoms. Conclusions: The stable, neutral and lipophilic complex, 99 Tc m -TRODAT-1, can be accumulated in the striatal area, where DAT is concentrated, high quality images can be obtained. It suggests that 99 Tc m -TRODAT-1 might be a safe and effective tracer for monitoring the variation in DAT which is associated with various neurodegenerative diseases

  18. Resveratrol: A review of preclinical studies for human cancer prevention

    International Nuclear Information System (INIS)

    Athar, Mohammad; Back, Jung Ho; Tang Xiuwei; Kim, Kwang Ho; Kopelovich, Levy; Bickers, David R.; Kim, Arianna L.

    2007-01-01

    The search for novel and effective cancer chemopreventive agents has led to the identification of various naturally occurring compounds one of which is resveratrol (trans-3,4',5-trihydroxystilbene), a phytoalexin derived from the skin of grapes and other fruits. Resveratrol is known to have potent anti-inflammatory and antioxidant effects and to inhibit platelet aggregation and the growth of a variety of cancer cells. Its potential chemopreventive and chemotherapeutic activities have been demonstrated in all three stages of carcinogenesis (initiation, promotion, and progression), in both chemically and UVB-induced skin carcinogenesis in mice, as well as in various murine models of human cancers. Evidence from numerous in vitro and in vivo studies has confirmed its ability to modulate various targets and signaling pathways. This review discusses the current preclinical and mechanistic data available and assesses resveratrol's anticancer effects to support its potential as an anticancer agent in human populations

  19. Comparative study of FDG-PET and sestamibi-SPECT in the diagnosis of secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Higuchi, T.; Ozawa, K.; Oriuchi, N.; Khan, N.; Endo, K.; Otake, H.; Matsubara, K.

    2002-01-01

    Aim: FDG-PET is reported to be more accurate in preoperative localization of hyper functioning parathyroid gland of primary hyperparathyroidism in comparison with sestamibi-SPECT by Neumann et al. However, its usefulness in the diagnosis of secondary hyperparathyroidism has not been reported yet. In this study, we've performed the direct comparison of the usefulness of FDG-PET and sestamibi-SPECT in the detection of abnormal parathyroid tissue in the patients of secondary hyperparathyroidism under hemodilysis. Material and Methods: One primary and 5 secondary hyperparathyroidism patients underwent FDG-PET and sestamibi-SPECT. After overnight fasting, 300 to 400 MBq of FDG was intravenously injected, followed by whole body PET image acquisition after 50 minutes. In the same day before FDG-PET, 600 MBq of sestamibi was injected and early and delayed planar image and delayed SPECT image has been obtained. Visual interpretation of the abnormal parathyroid uptake has been performed by 2 experienced nuclear physician independently. Results: In the secondary cases, FDG-PET shows no hyper functioning gland in all 5 cases, whereas sestamibi-SPECT shows 8 hyper functioning glands. In contrast, hyper functioning gland of the primary hyperparathyroidism case has been clearly visualized only by FDG-PET. Conclusion: Although FDG-PET is very useful in detecting hyper functioning gland in primary hyperparathyroidism, it is not useful in secondary hyperparathyroidism. Further pathological analysis about the different glucose metabolism of primary and secondary hyper functioning gland should be added in the future study

  20. A new method for quantification of pulmonary thallium uptake in myocardial SPECT studies

    International Nuclear Information System (INIS)

    Mannting, F.

    1990-01-01

    Quantified pulmonary thallium 201 (Tl) uptake was assessed in 32 normal people and 66 patients with suspected coronary artery disease (CAD) by a new method utilizing SPECT acquisition data. In 26 subjects pulmonary uptake was assessed with both SPECT and planar techniques. Pulmonary/myocardial (PM) ratios for the whole right lung (PM1) and for the upper left lung (PM2) were computed and compared with stress test, coronary angiography, radionuclide angiography (ERNA), and quantified Tl SPECT results. Excellent correlation between pulmonary uptake assessed by planar and SPECT technique was disclosed (r=0.92). The PM ratio (PM1/PM2) sensitivity and specificity in patients with CAD was 88%/92% and 60%/70%, for predicting perfusion abnormalities 90%/87% and 88%/88%, and an inverse correlation to LVEF was found (r=-0.40/r=-0.37, P<0.01). Significant correlations to coronary angiography findings (r=0.54/r=0.49, P<0.001) and to number of vessel territories with abnormal perfusion (r=0.70/r=0.69, P<0.001) were seen. Thus, pulmonary Tl uptake can be assessed in SPECT studies. The new method's discriminative ability seems higher than that of the standard planar technique currently employed. Positive correlations to coronary angiography findings and even stronger ones to perfusion abnormalities were observed. (orig.)

  1. Semi-automatic detection and correction of body organ motion, particularly cardiac motion in SPECT studies

    International Nuclear Information System (INIS)

    Quintana, J.C.; Caceres, F.; Vargas, P.

    2002-01-01

    Aim: Detect patient motion during SPECT imaging. Material and Method: SPECT study is carried out on a patient's body organ, such as the heart, and frame of image data are thereby acquired. The image data in these frames are subjected to a series of mappings and computations, from which frame containing a significant quantity of organ motion can be identified. Quantification of motion occurs by shifting some of the mapped data within a predetermined range, and selecting that data shift which minimizes the magnitude of a motion sensitive mathematical function. The sensitive mathematical function is constructed from all set of image frames using the pixel data within a region covering the body organ. Using cine display of planar image data, the operator defines the working region by marking two points, which define two horizontal lines covering the area of the body organ. This is the only operator intervention. The mathematical function integrates pixel data from all set of image frames and therefore does not use derivatives which may cause distortion in noisy data. Moreover, as a global function, this method is superior than that using frame-to-frame cross-correlation function to identify motion between adjacent frames. Using standard image processing software, the method was implemented computationally. Ten SPECT studies with movement (Sestamibi cardiac studies and 99m-ECD brain SPECT studies) were selected plus two others with no movement. The acquisition SPECT protocol for the cardiac study was as follow: Step and shoot mode, non-circular orbit, 64 stops 20s each, 64x64x16 matrix and LEHR colimator. For the brain SPECT, 128 stops over 360 0 were used. Artificial vertical displacements (±1-2 pixels) over several frames were introduced in those studies with no movement to simulate patient motion. Results: The method was successfully tested in all cases and was capable to recognize SPECT studies with no body motion as well as those with body motion (both from the

  2. 99mTc-MIBI-SPECT-studies in the evaluation of brain tumors

    International Nuclear Information System (INIS)

    Ambrus, E.; Pavics, L.; Gruenwald, F.; Barath, B.; Tiszlavicz, L.; Bender, H.; Menzel, C.; Almasi, L.; Lang, J.; Bodosi, M.; Biersack, H.J.; Csernay, L.

    1994-01-01

    Brain SPECT studies were performed 5 and 60 minutes after 99m Tc-MIBI administration in 41 patients with brain tumors confirmed by CT and surgical removal (13 meningeomas, 8 astrocytomas grades I-III, 10 glioblastomas, 10 metastases). 99m Tc-MIBI uptake was found in 32 out of 41 brain tumors. According to the semiquantitative SPECT analysis, the tumor/non tumor radios revealed a statistically significant difference in the early tracer uptake between meningeomas and astrocytomas (+4.73±2.91 vs -1.75±0.75, p 99m Tc-MIBI uptake and its changes with time. We concluded that the combination of an early and late 99m Tc-MIBI brain SPECT may be helpful in the non invasive histological classification of brain tumors and the determination of the grade of theirs malignancy. (orig.) [de

  3. sup 123 I-IMP SPECT study on patients with amnestic syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Abe, Shinei; Arai, Hisayuki; Takasaki, Masaru; Suzuki, Takanari; Abe, Kimihiko; Amino, Saburo [Tokyo Medical Coll. (Japan)

    1992-06-01

    Regional cerebral blood flow was studied using single photon emission CT (SPECT) with {sup 123}I-IMP to elucidate the pathophysiology of amnesia. Four patients with amnestic syndrome diagnosed by DSM-III-R criteria were investigated. SPECT images demonstrated definite hypoperfusion of the temporoparietal lobe and relative sparing of motorsensory and occipital cortices in two out of four patients. Since these abnormalities of regional cerebral blood flow have been considered to be characteristic findings in dementia of the Alzheimer type, two patients with temporoparietal hypoperfusion are suggested to manifest the early stage of dementia of the Alzheimer type. Our observations suggest that {sup 123}I-IMP SPECT is an useful madality in the diagnosis of the early stage of dementia of the Alzheimer type, especially in patients with only memory impairment. (author).

  4. 123I-IMP SPECT study on patients with amnestic syndrome

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Abe, Shinei; Arai, Hisayuki; Takasaki, Masaru; Suzuki, Takanari; Abe, Kimihiko; Amino, Saburo

    1992-01-01

    Regional cerebral blood flow was studied using single photon emission CT (SPECT) with 123 I-IMP to elucidate the pathophysiology of amnesia. Four patients with amnestic syndrome diagnosed by DSM-III-R criteria were investigated. SPECT images demonstrated definite hypoperfusion of the temporoparietal lobe and relative sparing of motorsensory and occipital cortices in two out of four patients. Since these abnormalities of regional cerebral blood flow have been considered to be characteristic findings in dementia of the Alzheimer type, two patients with temporoparietal hypoperfusion are suggested to manifest the early stage of dementia of the Alzheimer type. Our observations suggest that 123 I-IMP SPECT is an useful madality in the diagnosis of the early stage of dementia of the Alzheimer type, especially in patients with only memory impairment. (author)

  5. Feasibility study of a novel general purpose CZT-based digital SPECT camera: initial clinical results.

    Science.gov (United States)

    Goshen, Elinor; Beilin, Leonid; Stern, Eli; Kenig, Tal; Goldkorn, Ronen; Ben-Haim, Simona

    2018-03-14

    The performance of a prototype novel digital single-photon emission computed tomography (SPECT) camera with multiple pixelated CZT detectors and high sensitivity collimators (Digital SPECT; Valiance X12 prototype, Molecular Dynamics) was evaluated in various clinical settings. Images obtained in the prototype system were compared to images from an analog camera fitted with high-resolution collimators. Clinical feasibility, image quality, and diagnostic performance of the prototype were evaluated in 36 SPECT studies in 35 patients including bone (n = 21), brain (n = 5), lung perfusion (n = 3), and parathyroid (n = 3) and one study each of sentinel node and labeled white blood cells. Images were graded on a scale of 1-4 for sharpness, contrast, overall quality, and diagnostic confidence. Digital CZT SPECT provided a statistically significant improvement in sharpness and contrast in clinical cases (mean score of 3.79 ± 0.61 vs. 3.26 ± 0.50 and 3.92 ± 0.29 vs. 3.34 ± 0.47 respectively, p < 0.001 for both). Overall image quality was slightly higher for the digital SPECT but not statistically significant (3.74 vs. 3.66). CZT SPECT provided significantly improved image sharpness and contrast compared to the analog system in the clinical settings evaluated. Further studies will evaluate the diagnostic performance of the system in large patient cohorts in additional clinical settings.

  6. SPECT/CT co-registration of nuclear medicine studies and technologists: challenges and victories

    International Nuclear Information System (INIS)

    Cameron, P.J.

    2002-01-01

    Full text: A dual modality SPECT/CT gamma camera was installed in the Department of Nuclear Medicine at Fremantle Hospital, WA in 2000. The challenges were satisfying the requirements of the Radiological Advisory Council of WA with respect to room modifications and presence of a radiographer during CT acquisitions and once installation was complete, learning to operate the camera in dual modality mode. The victories are making CT/SPECT acquisitions a simple and routine procedure and the impact of the co-registered studies in both diagnostic and therapeutic applications in our practice. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  7. Preliminary results of SPECT studies with 99mTc-HMPAO in endogenous psychoses

    International Nuclear Information System (INIS)

    Wilhelm, K.R.; Georgi, P.; Schroeder, J.; Henningsen, H.; Sauer, H.

    1989-01-01

    18 psychopharmacologically treated patients (7 schizophrenics, 5 schizoaffectives, 6 depressives) were studied using 99m Tc-HMPAO-SPECT of the brain. The regional cerebral blood flow was measured in three transversal sections (infra-/supraventricular, ventricular) within 6 regions of interest (ROI) respectively (one frontal, one parietal and one occipital in each hemisphere). Corresponding ROIs of the same section in each hemisphere were compared. In the schizophrenics there was a significantly reduced perfusion in the left frontal region of the infraventricular and ventricular section (p 99m Tc-HMPAO-SPECT may be helpful in finding cerebral abnormalities in endogenous psychoses. (orig.) [de

  8. Marchiafava-Bignami disease: a case studied with brain magnetic resonance and SPECT

    International Nuclear Information System (INIS)

    Cardozo Oliver, J.; Casas Parera, Ignacio; Libere, G.; Malagold, S.

    2006-01-01

    Objective: To show the correlation between brain magnetic resonance images (MRI) and single-photon-emission computed tomography (SPECT) in a patient with Marchiafava-Bignami (MB) disease. Background: MB disease is a rare disorder associated with chronic alcoholism. It is characterized by symmetric demyelination of corpus callosum (CC) and adjacent white matter. These lesions can be demonstrated both by computed tomography or/and MRI. Scarce information is available about MRI and SPECT according to the research done. Design/methods: A 79-year-old white man with a history of excessive alcohol consumption (predominantly wine) was admitted to our Institute. A decrease in his physical activity was evidenced in the two years prior to admission and in the last twelve months progressive dementia with hallucinations and severe apathy developed. On admission neurologic examination showed papillae pale in both eyes, left hearing loss, action tremor of upper limbs and proximal hyporeflexia with distal arreflexia of all four limbs was observed. Affectation of higher cortical functions was evident. Cerebrospinal fluid was normal and serology for syphilis and HIV were negative. Both renal and hepatic functions were normal. Brain MRI and SPECT were performed. The patient died 70 days after diagnosis of MB disease. Results: MRI scans of the brain showed multiple hyperintense T2-weighted lesions in white matter and basal ganglia. Cortical atrophy, especially in the fronto-temporal areas, and a CC thickness reduction were also observed. Sagittal view showed an irregular cavitation in the genu of the CC, hypointense and hyperintense on T1 and T2-weighted images respectively. The SPECT showed an abnormal low perfusion on both frontal lobes, left temporo-parietal lobes and right basal ganglia. Conclusion: The clinical features and MRI were consistent with the diagnosis of MB disease. MRI and SPECT studies showed the connection between the lesion in the CC and bilateral cortical

  9. Voxel Based Analysis of Surgical Revascularization for Moyamoya Disease: Pre- and Postoperative SPECT Studies.

    Directory of Open Access Journals (Sweden)

    Yasutaka Fushimi

    Full Text Available Moyamoya disease (MMD is a chronic, progressive, cerebrovascular occlusive disease that causes abnormal enlargement of collateral pathways (moyamoya vessels in the region of the basal ganglia and thalamus. Cerebral revascularization procedures remain the preferred treatment for patients with MMD, improving the compromised cerebral blood flow (CBF. However, voxel based analysis (VBA of revascularization surgery for MMD based on data from pre- and postoperative data has not been established. The latest algorithm called as Diffeomorphic Anatomical Registration Through Exponentiated Lie Algebra (DARTEL has been introduced for VBA as the function of statistical parametric mapping (SPM8, and improved registration has been achieved by SPM8 with DARTEL. In this study, VBA was conducted to evaluate pre- and postoperative single photon emission computed tomography (SPECT images for MMD by SPM8 with DARTEL algorithm, and the results were compared with those from SPM8 without DARTEL (a conventional method. Thirty-two patients with MMD who underwent superficial temporal artery-middle cerebral artery (STA-MCA bypass surgery as the first surgery were included and all patients underwent pre- and postoperative 3D T1-weighted imaging and SPECT. Pre- and postoperative SPECT images were registered to 3D T1-weighted images, then VBA was conducted. Postoperative SPECT showed more statistically increased CBF areas in the bypassed side cerebral hemisphere by using SPM8 with DARTEL (58,989 voxels; P<0.001, and increased ratio of CBF after operation was less than 15%. Meanwhile, postoperative SPECT showed less CBF increased areas by SPM8 without DARTEL. In conclusion, VBA was conducted for patients with MMD, and SPM8 with DARTEL revealed that postoperative SPECT showed statistically significant CBF increases over a relatively large area and with at most 15% increase ratio.

  10. Comparative analysis of MR imaging, Ictal SPECT and EEG in temporal lobe epilepsy: a prospective IAEA multi-center study

    Energy Technology Data Exchange (ETDEWEB)

    Zaknun, John J. [University Hospital of Innsbruck, Department of Nuclear Medicine, Innsbruck (Austria); International Atomic Energy Agency (IAEA), Nuclear Medicine Section, Division of Human Health, Vienna (Austria); IAEA, Nuclear Medicine Section, Division of Human Health, Wagramer Strasse 5, P.O. Box 100, Wien (Austria); Bal, Chandrasekhar [All India Institute of Medical Sciences, Department of Nuclear Medicine, New Delhi (India); Maes, Alex [Katholieke Universiteit Leuven, Leuven (Belgium); AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); Tepmongkol, Supatporn [Chulalongkorn University, Nuclear Medicine Division, Department of Radiology, Bangkok (Thailand); Vazquez, Silvia [Instituto de Investigaciones Neurologicas, FLENI, Department of Radiology, Buenos Aires (Argentina); Dupont, Patrick [Katholieke Universiteit Leuven, Leuven (Belgium); Dondi, Maurizio [Ospedale Maggiore, Department of Nuclear Medicine, Bologna (Italy); International Atomic Energy Agency (IAEA), Nuclear Medicine Section, Division of Human Health, Vienna (Austria)

    2008-01-15

    MR imaging, ictal single-photon emission CT (SPECT) and ictal EEG play important roles in the presurgical localization of epileptic foci. This multi-center study was established to investigate whether the complementary role of perfusion SPECT, MRI and EEG for presurgical localization of temporal lobe epilepsy could be confirmed in a prospective setting involving centers from India, Thailand, Italy and Argentina. We studied 74 patients who underwent interictal and ictal EEG, interictal and ictal SPECT and MRI before surgery of the temporal lobe. In all but three patients, histology was reported. The clinical outcome was assessed using Engel's classification. Sensitivity values of all imaging modalities were calculated, and the add-on value of SPECT was assessed. Outcome (Engel's classification) in 74 patients was class I, 89%; class II, 7%; class III, 3%; and IV, 1%. Regarding the localization of seizure origin, sensitivity was 84% for ictal SPECT, 70% for ictal EEG, 86% for MRI, 55% for interictal SPECT and 40% for interictal EEG. Add-on value of ictal SPECT was shown by its ability to correctly localize 17/22 (77%) of the seizure foci missed by ictal EEG and 8/10 (80%) of the seizure foci not detected by MRI. This prospective multi-center trial, involving centers from different parts of the world, confirms that ictal perfusion SPECT is an effective diagnostic modality for correctly identifying seizure origin in temporal lobe epilepsy, providing complementary information to ictal EEG and MRI. (orig.)

  11. Comparative analysis of MR imaging, Ictal SPECT and EEG in temporal lobe epilepsy: a prospective IAEA multi-center study

    International Nuclear Information System (INIS)

    Zaknun, John J.; Bal, Chandrasekhar; Maes, Alex; Tepmongkol, Supatporn; Vazquez, Silvia; Dupont, Patrick; Dondi, Maurizio

    2008-01-01

    MR imaging, ictal single-photon emission CT (SPECT) and ictal EEG play important roles in the presurgical localization of epileptic foci. This multi-center study was established to investigate whether the complementary role of perfusion SPECT, MRI and EEG for presurgical localization of temporal lobe epilepsy could be confirmed in a prospective setting involving centers from India, Thailand, Italy and Argentina. We studied 74 patients who underwent interictal and ictal EEG, interictal and ictal SPECT and MRI before surgery of the temporal lobe. In all but three patients, histology was reported. The clinical outcome was assessed using Engel's classification. Sensitivity values of all imaging modalities were calculated, and the add-on value of SPECT was assessed. Outcome (Engel's classification) in 74 patients was class I, 89%; class II, 7%; class III, 3%; and IV, 1%. Regarding the localization of seizure origin, sensitivity was 84% for ictal SPECT, 70% for ictal EEG, 86% for MRI, 55% for interictal SPECT and 40% for interictal EEG. Add-on value of ictal SPECT was shown by its ability to correctly localize 17/22 (77%) of the seizure foci missed by ictal EEG and 8/10 (80%) of the seizure foci not detected by MRI. This prospective multi-center trial, involving centers from different parts of the world, confirms that ictal perfusion SPECT is an effective diagnostic modality for correctly identifying seizure origin in temporal lobe epilepsy, providing complementary information to ictal EEG and MRI. (orig.)

  12. Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study

    International Nuclear Information System (INIS)

    Genovesi, Dario; Giorgetti, Assuero; Gimelli, Alessia; Kusch, Annette; D'Aragona Tagliavia, Irene; Casagranda, Mirta; Marzullo, Paolo; Cannizzaro, Giorgio; Giubbini, Raffaele; Bertagna, Francesco; Fagioli, Giorgio; Rossi, Massimiliano; Romeo, Annadina; Bertolaccini, Pietro; Bonini, Rita

    2011-01-01

    In clinical myocardial single photon emission computed tomography (SPECT), attenuation artefacts may cause a loss of specificity in the identification of diseased vessels that can be corrected by means of gated SPECT (GSPECT) acquisition or CT attenuation correction (AC). The purpose of this multicentre study was to assess the impact of GSPECT and AC on the diagnostic performance of myocardial scintigraphy, according to patient's sex, body mass index (BMI) and site of coronary artery disease (CAD). We studied a group of 104 patients who underwent coronary angiography within 1 month before or after the SPECT study. Patients with a BMI > 27 were considered ''overweight''. Attenuation-corrected and standard GSPECT early images were randomly interpreted by three readers blinded to the clinical data. In the whole group, GSPECT and AC showed a diagnostic accuracy of 86.5% (sensitivity 82%, specificity 93%) and 77% (sensitivity 75.4%, specificity 81.4%), respectively (p < 0.05). In women, when anterior ischaemia was matched with CAD, AC failed to show any increase in specificity (AC 63.6% vs GSPECT 63.6%) with evident loss of sensitivity (AC 72.7% vs GSPECT 90.9%). AC significantly improved SPECT specificity in the identification of right CAD in overweight men (AC 100% vs GSPECT 66.7%, p <0.05). AC improved specificity in the evaluation of right CAD in overweight men. In the other evaluable subgroups specificity was not significantly affected while sensitivity was frequently reduced. (orig.)

  13. Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study

    Energy Technology Data Exchange (ETDEWEB)

    Genovesi, Dario; Giorgetti, Assuero; Gimelli, Alessia; Kusch, Annette; D' Aragona Tagliavia, Irene; Casagranda, Mirta; Marzullo, Paolo [Fondazione CNR-Regione Toscana ' ' G. Monasterio' ' , Nuclear Medicine, Pisa (Italy); Cannizzaro, Giorgio [A.O.V. Cervello, Nuclear Medicine, Palermo (Italy); Giubbini, Raffaele; Bertagna, Francesco [Spedali Civili, Nuclear Medicine, Brescia (Italy); Fagioli, Giorgio; Rossi, Massimiliano; Romeo, Annadina [Ospedale Maggiore, Nuclear Medicine, Bologna (Italy); Bertolaccini, Pietro; Bonini, Rita [Ospedale SS Giacomo e Cristoforo, Nuclear Medicine, Massa (Italy)

    2011-10-15

    In clinical myocardial single photon emission computed tomography (SPECT), attenuation artefacts may cause a loss of specificity in the identification of diseased vessels that can be corrected by means of gated SPECT (GSPECT) acquisition or CT attenuation correction (AC). The purpose of this multicentre study was to assess the impact of GSPECT and AC on the diagnostic performance of myocardial scintigraphy, according to patient's sex, body mass index (BMI) and site of coronary artery disease (CAD). We studied a group of 104 patients who underwent coronary angiography within 1 month before or after the SPECT study. Patients with a BMI > 27 were considered ''overweight''. Attenuation-corrected and standard GSPECT early images were randomly interpreted by three readers blinded to the clinical data. In the whole group, GSPECT and AC showed a diagnostic accuracy of 86.5% (sensitivity 82%, specificity 93%) and 77% (sensitivity 75.4%, specificity 81.4%), respectively (p < 0.05). In women, when anterior ischaemia was matched with CAD, AC failed to show any increase in specificity (AC 63.6% vs GSPECT 63.6%) with evident loss of sensitivity (AC 72.7% vs GSPECT 90.9%). AC significantly improved SPECT specificity in the identification of right CAD in overweight men (AC 100% vs GSPECT 66.7%, p <0.05). AC improved specificity in the evaluation of right CAD in overweight men. In the other evaluable subgroups specificity was not significantly affected while sensitivity was frequently reduced. (orig.)

  14. Contribution of subtraction ictal SPECT coregistered to MRI to epilepsy surgery. A multicenter study

    International Nuclear Information System (INIS)

    Matsuda, Hiroshi; Matsuda, Kazumi; Nakamura, Fumihiro

    2009-01-01

    A multicenter prospective study was performed to assess the additional value of a subtraction ictal single photon emission computed tomography (SPECT) coregistered to MRI (SISCOM) technique to traditional side-by-side comparison of ictal- and interictal SPECT images in epilepsy surgery. One hundred and twenty-three patients with temporal and extratemporal lobe epilepsy who had undergone epilepsy surgery after evaluation of scalp ictal and interictal electroencephalogram (EEG), MRI, and ictal and interictal SPECT scans were followed up in terms of postsurgical outcome for a period of at least 1 year. Three reviewers localized the epileptogenic focus using ictal and interictal SPECT images first by side-by-side comparison and subsequently by SISCOM. Concordance of the localization of the epileptogenic focus by SPECT diagnosis with the surgical site and inter-observer agreement between reviewers was compared between side-by-side comparison and SISCOM. Logistic regression analysis was performed in predicting the surgical outcome with the dependent variable being the achievement of a good postsurgical outcome and the independent variables using the SISCOM, side-by-side comparison of ictal and interictal SPECT images, MRI, and scalp ictal EEG. The SISCOM presented better concordance in extratemporal lobe epilepsy and less concordance in temporal lobe epilepsy than side-by-side comparison. Inter-observer concordance was higher in SISCOM than in side-by-side comparison. Much higher concordance of the epileptogenic focus by SPECT diagnosis with the surgical site was obtained in patients with good surgical outcome than in those with poor surgical outcome. These differences in concordance between good and poor surgical outcomes were greater in SISCOM than in side-by-side comparison. Logistic regression analysis showed the highest odds ratio of 12.391 (95% confidence interval; 3.319, 46.254) by SISCOM evaluation for concordance of the epileptogenic focus with the surgical site

  15. Novel technology to prepare oral formulations for preclinical safety studies.

    Science.gov (United States)

    Niwa, Toshiyuki; Hashimoto, Naofumi

    2008-02-28

    A novel method to prepare oral formulations, normally suspended dosage form, for preclinical safety studies in animals has been developed using a rotation/revolution mixer. Small hard balls made of zirconia were added to the mixing process to evaluate effectiveness in making a high quality suspension. The driving with balls loaded in the cylindrical container (vessel) of the mixer was quite efficient in dispersing and milling the particles of the active pharmaceutical ingredient (API) in an aqueous medium. The API powder and a small amount of oral aqueous medium (vehicle) were successfully mixed by the spinning motion of the balls in the vessel as though the paste-like suspension was kneaded with a mortar and pestle. It was found that the milled suspension with the mean size of 10-20microm could be prepared, in addition finer milling of less than 10microm could be achieved by selecting the material of vessel. Optimum driving conditions including mixing time, size and quantity of balls, and the standard operational procedure was established using compounds varying in physicochemical properties. The particle size and quantitative analysis by HPLC showed that the resultant suspension was well-milled and highly homogeneous with the nearly intended concentration of API. The proposed method established by this experiment could be applied to the actual safety studies in the real preparation scale of oral suspension.

  16. Improving treatment of neurodevelopmental disorders: recommendations based on preclinical studies.

    Science.gov (United States)

    Homberg, Judith R; Kyzar, Evan J; Stewart, Adam Michael; Nguyen, Michael; Poudel, Manoj K; Echevarria, David J; Collier, Adam D; Gaikwad, Siddharth; Klimenko, Viktor M; Norton, William; Pittman, Julian; Nakamura, Shun; Koshiba, Mamiko; Yamanouchi, Hideo; Apryatin, Sergey A; Scattoni, Maria Luisa; Diamond, David M; Ullmann, Jeremy F P; Parker, Matthew O; Brown, Richard E; Song, Cai; Kalueff, Allan V

    2016-01-01

    Neurodevelopmental disorders (NDDs) are common and severely debilitating. Their chronic nature and reliance on both genetic and environmental factors makes studying NDDs and their treatment a challenging task. Herein, the authors discuss the neurobiological mechanisms of NDDs, and present recommendations on their translational research and therapy, outlined by the International Stress and Behavior Society. Various drugs currently prescribed to treat NDDs also represent a highly diverse group. Acting on various neurotransmitter and physiological systems, these drugs often lack specificity of action, and are commonly used to treat multiple other psychiatric conditions. There has also been relatively little progress in the development of novel medications to treat NDDs. Based on clinical, preclinical and translational models of NDDs, our recommendations cover a wide range of methodological approaches and conceptual strategies. To improve pharmacotherapy and drug discovery for NDDs, we need a stronger emphasis on targeting multiple endophenotypes, a better dissection of genetic/epigenetic factors or "hidden heritability," and a careful consideration of potential developmental/trophic roles of brain neurotransmitters. The validity of animal NDD models can be improved through discovery of novel (behavioral, physiological and neuroimaging) biomarkers, applying proper environmental enrichment, widening the spectrum of model organisms, targeting developmental trajectories of NDD-related behaviors and comorbid conditions beyond traditional NDDs. While these recommendations cannot be addressed all in once, our increased understanding of NDD pathobiology may trigger innovative cross-disciplinary research expanding beyond traditional methods and concepts.

  17. Validation of a method for accurate and highly reproducible quantification of brain dopamine transporter SPECT studies

    DEFF Research Database (Denmark)

    Jensen, Peter S; Ziebell, Morten; Skouboe, Glenna

    2011-01-01

    In nuclear medicine brain imaging, it is important to delineate regions of interest (ROIs) so that the outcome is both accurate and reproducible. The purpose of this study was to validate a new time-saving algorithm (DATquan) for accurate and reproducible quantification of the striatal dopamine t...... transporter (DAT) with appropriate radioligands and SPECT and without the need for structural brain scanning....

  18. Assessment of congenital heart disease by a thallium-201 SPECT study in children

    International Nuclear Information System (INIS)

    Ishii, Iwao; Nakajima, Kenichi; Taki, Junichi; Taniguchi, Mitsuru; Bunko, Hisashi; Tonami, Norihisa; Hisada, Kinichi; Ohno, Takashi

    1993-01-01

    The characteristics of correlation between the right-to-left ventricular systolic pressure ratios (RVp/LVp) and the thallium-201 right-to-left ventricular ( 201 Tl R/L) count ratios was investigated in children with various congenital heart diseases. High-resolution three-headed SPECT system equipped with either parallel-hole or fan-beam collimators was used. In a total of 102 patients, the correlation between RVp/LVp and 201 Tl R/L average count ratios was good in both planar (r=0.89, p=0.0001) and SPECT studies (r=0.80, p=0.0001). Quantitative analysis of myocardial uptake by SPECT demonstrated the characteristic pattern of each disease as well as the differences in the right ventricular overload types. When the linear regression analysis was performed in each heart disease, ventricular septal defect showed most excellent correlation. Complex heart anomalies also showed positive correlation (r=0.51, p=0.05) with RVp/LVp, and it can be used to estimate right ventricular pressure. After surgical treatment of tetralogy of Fallot and pulmonary stenosis, the decrease of 201 Tl R/L count ratio was in accordance with improvement of right ventricular overload. We conclude that 201 Tl SPECT study can be a good indicator for estimation of right ventricular pressure. (author)

  19. Determination of hyperactive areas of Cortex Cerebri with using brain SPECT study

    International Nuclear Information System (INIS)

    Stepien, A.; Pawlus, J.; Wasilewska-Radwanska, M.

    2004-01-01

    The aim of this study was the assessment of the ability to apply of SPECT technique to determination of hyperactive areas of cortex cerebri. Analysis included 50 patients (mean aged 44 - 58). Brain SPECT scanning was performed after 1 hour after the intravenous injection of 740 MBq of ethylcisteinate dimmer labeled 99m Technetium (99mTc-ECD) with the use one-head gamma camera with a low-energy, ultra-high resolution collimator. Qualitative and quantitative analysis was performed using specialised software. In 20 cases normal biodistribution of the radiotracer was observed (hyperactive areas in cerebellum and occiput). In patients with psychiatric and neurological disturbances hyperactive areas were visualized in 25 cases in temporal lobes, in 4 cases in parietal lobes and in 1 patient in frontal area and basal ganglia. It is concluded that a number of factors limit the wide-scale use of SPECT, including the sophistication of imaging equipment (single-head cameras are inferior to the newer multihead units) and the experience of the physicians interpreting the scans and utilizing the data. In many diseases physicians do not know which areas of the patient's brain according disorders. Brain SPECT study can be a very useful tool to evaluation of hyperactive areas of cortex cerebri. This technique visualization of cortex cerebri completes standard analysis of disorders of brain activity

  20. Quantitative study on lung volume and lung perfusion using SPECT and CT in thoracal tumors

    International Nuclear Information System (INIS)

    Beyer-Enke, S.A.; Goerich, J.; Strauss, L.G.

    1988-01-01

    22 patients with space occupying lesions in the thoracal region were investigated by computer tomography and by perfusion scintigraphy using SPECT. In order to evaluate the CT images quantitatively, the lung volume was determined using approximation method and compared with the perfusion in the SPECT study. For this, anatomically equivalent transaxial SPECT slices had been coordinated to the CT slices. Between the determined lung volumes and the activity in the ocrresponding layers, a statistically significant correlation was found. It could be shown that the stronger perfusion, frequently observed at the right side of the healthy lung, may be explained by an higher volume of the right pulmonary lobe. Whereas in benign displacing processes the relation activity to volume was similar to the one of the healthy lung, a strongly reduced perfusion together with inconspicuous lung volumes became apparent with malignant tumors. In addition to the great morphological evidence of CT and SPECT studies, additional informations regarding the dignity of displacing processes may be derived from the quantitative evaluation of both methods. (orig.) [de

  1. Preclinical properties and human in vivo assessment of 123 I-ABC577 as a novel SPECT agent for imaging amyloid-β

    Science.gov (United States)

    Okumura, Yuki; Kobayashi, Ryohei; Onishi, Takako; Shoyama, Yoshinari; Barret, Olivier; Alagille, David; Jennings, Danna; Marek, Kenneth; Seibyl, John; Tamagnan, Gilles; Tanaka, Akihiro; Shirakami, Yoshifumi

    2016-01-01

    Abstract Non-invasive imaging of amyloid-β in the brain, a hallmark of Alzheimer’s disease, may support earlier and more accurate diagnosis of the disease. In this study, we assessed the novel single photon emission computed tomography tracer 123 I-ABC577 as a potential imaging biomarker for amyloid-β in the brain. The radio-iodinated imidazopyridine derivative 123 I-ABC577 was designed as a candidate for a novel amyloid-β imaging agent. The binding affinity of 123 I-ABC577 for amyloid-β was evaluated by saturation binding assay and in vitro autoradiography using post-mortem Alzheimer’s disease brain tissue. Biodistribution experiments using normal rats were performed to evaluate the biokinetics of 123 I-ABC577. Furthermore, to validate 123 I-ABC577 as a biomarker for Alzheimer’s disease, we performed a clinical study to compare the brain uptake of 123 I-ABC577 in three patients with Alzheimer’s disease and three healthy control subjects. 123 I-ABC577 binding was quantified by use of the standardized uptake value ratio, which was calculated for the cortex using the cerebellum as a reference region. Standardized uptake value ratio images were visually scored as positive or negative. As a result, 123 I-ABC577 showed high binding affinity for amyloid-β and desirable pharmacokinetics in the preclinical studies. In the clinical study, 123 I-ABC577 was an effective marker for discriminating patients with Alzheimer’s disease from healthy control subjects based on visual images or the ratio of cortical-to-cerebellar binding. In patients with Alzheimer’s disease, 123 I-ABC577 demonstrated clear retention in cortical regions known to accumulate amyloid, such as the frontal cortex, temporal cortex, and posterior cingulate. In contrast, less, more diffuse, and non-specific uptake without localization to these key regions was observed in healthy controls. At 150 min after injection, the cortical standardized uptake value ratio increased by ∼60% in patients

  2. A crowdsourcing model for creating preclinical medical education study tools.

    Science.gov (United States)

    Bow, Hansen C; Dattilo, Jonathan R; Jonas, Andrea M; Lehmann, Christoph U

    2013-06-01

    During their preclinical course work, medical students must memorize and recall substantial amounts of information. Recent trends in medical education emphasize collaboration through team-based learning. In the technology world, the trend toward collaboration has been characterized by the crowdsourcing movement. In 2011, the authors developed an innovative approach to team-based learning that combined students' use of flashcards to master large volumes of content with a crowdsourcing model, using a simple informatics system to enable those students to share in the effort of generating concise, high-yield study materials. The authors used Google Drive and developed a simple Java software program that enabled students to simultaneously access and edit sets of questions and answers in the form of flashcards. Through this crowdsourcing model, medical students in the class of 2014 at the Johns Hopkins University School of Medicine created a database of over 16,000 questions that corresponded to the Genes to Society basic science curriculum. An analysis of exam scores revealed that students in the class of 2014 outperformed those in the class of 2013, who did not have access to the flashcard system, and a survey of students demonstrated that users were generally satisfied with the system and found it a valuable study tool. In this article, the authors describe the development and implementation of their crowdsourcing model for creating study materials, emphasize its simplicity and user-friendliness, describe its impact on students' exam performance, and discuss how students in any educational discipline could implement a similar model of collaborative learning.

  3. Determination of optimum filter in myocardial SPECT: A phantom study

    International Nuclear Information System (INIS)

    Takavar, A.; Shamsipour, Gh.; Sohrabi, M.; Eftekhari, M.

    2004-01-01

    Background: In myocardial perfusion SPECT images are degraded by photon attenuation, the distance-dependent collimator, detector response and photons scatter. Filters greatly affect quality of nuclear medicine images. Materials and Methods: A phantom simulating heart left ventricle was built. About 1mCi of 99m Tc was injected into the phantom. Images was taken from this phantom. Some filters including Parzen, Hamming, Hanning, Butter worth and Gaussian were exerted on the phantom images. By defining some criteria such as contrast, signal to noise ratio, and defect size detectability, the best filter can be determined. Results: 0.325 Nyquist frequency and 0.5 nq was obtained as the optimum cut off frequencies respectively for hamming and handing filters. Order 11, cut off 0.45 Nq and order 20 cut off 0.5 Nq obtained optimum respectively for Butter worth and Gaussian filters. Conclusion: The optimum member of every filter's family was obtained

  4. A new method for brain functional study using Tc-99m HMPAO SPECT

    International Nuclear Information System (INIS)

    Momose, Toshimitsu; Kosaka, Noboru; Nishikawa, Junichi; Ohtake, Tohru; Watanabe, Toshiaki; Iio, Masahiro

    1989-01-01

    The distribution of 99m Tc-HMPAO in brain is in proportion to regional cerebral blood flow (rCBF) and can be interpreted as functional mapping. To evaluate local changes in CBF during neuropsychological testing, we developed a new subtraction method using HMPAO and SPECT. With patients resting, 15 mCi of HMPAO was injected and the first acquisition was performed, lasting a total of 10 minutes. Soon after the end of the first scan, patients were requested to undergo Buschke's memory test or to repeat words or numbers (repetition test). During the task, an additional 15 mCi of HMPAO was injected using the same position as in the first scan, and a second acquisition was started. A functional image was made by subtracting the image in the first scan from that in the second. In two patients with transient global amnesia and two normal controls, Buschke's memory test was performed in combination with SPECT. A relative increase in activity was seen in the thalamus, subthalamic area, hippocampus, and some cortial areas, apparently reflecting local functional change induced by the memory task. In two patients with moderate Alzheimer's disease with severe memory loss, no increase was detected in these areas. In one patient with aphasia, the repetition test with SPECT was correlated with the WADA test and dichotic listening test, and good agreement was obtained. In conclusion, our new SPECT technique is useful in detecting alterations in rCBF during mental activity and can be applied to neurophysiological studies. (author)

  5. Brain SPECT. SPECT in der Gehirndiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Feistel, H. (Erlangen-Nuernberg Univ., Erlangen (Germany). Nuklearmedizinische Klinik mit Poliklinik)

    1991-12-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG).

  6. Preclinical studies for increasing radiation response of malignant brain tumours

    International Nuclear Information System (INIS)

    Kalia, Vijay K.; Kumari, Kalyani; Sai Shyam; George, Jennifer; Shobha, A.G.; Chandrasekhar Sagar, B.K.; Lal, Jagath

    2013-01-01

    Malignant gliomas are the most common among the CNS cancers. Standard treatment for these tumours - comprises of surgery, followed by Radiotherapy (RT). Combination of Temozolomide (TMZ) increases survival, but hematological toxicities are also increased as compared to RT alone. The median survival depends on grade and location of tumour, as well as the age of the patient. Grade IV gliomas (GSMs) are third leading cause of cancer induced death in the age group of 15 to 34 years. Therefore, it is important to carry out further preclinical studies to develop more effective treatment of malignant gliomas. The present studies were carried out on different established malignant glioma cell lines. (U373MG) as well as primary monolayer cultures derived from biopsies obtained from patients with malignant gliomas. Exponentially growing cells were exposed to TMZ, Lonidamine (LND) (in 0.1% DMSO), or 2-Deoxy-D-Glucose (2-DG, aqueous solution) - with or without 60 Co-Gamma-rays (1- 2 Gy). The drugs were removed 4 hours after irradiation and the cultures were processed further for different assays of damage. Short term (4 h) treatments with TMZ 20 μM, LND 100 μM or their combination; did not induce micronuclei formation in the unirradiated cultures of U373MG cells. However, radiation (2 Gy) induced micronuclei was significantly increased by drug treatments. In primary cultures from different tumours, TMZ (≤ 10 μM) or 2-DG (1 mM), or gamma-irradiation (1-2 Gy) induced micronuclei and/ or apoptosis. The effects, however, varied in different tumours. These data show that clinically achievable, very low concentrations of these drugs could induce cellular damage and death; and increase radiosensitivity of malignant gliomas. Therefore, adjuvants like Lonidamine and 2-DG, with non-overlapping toxicities, could optimize treatment of malignant gliomas, by reducing the side effects of radio-chemotherapy. (author)

  7. Compton camera study for high efficiency SPECT and benchmark with Anger system

    Science.gov (United States)

    Fontana, M.; Dauvergne, D.; Létang, J. M.; Ley, J.-L.; Testa, É.

    2017-12-01

    Single photon emission computed tomography (SPECT) is at present one of the major techniques for non-invasive diagnostics in nuclear medicine. The clinical routine is mostly based on collimated cameras, originally proposed by Hal Anger. Due to the presence of mechanical collimation, detection efficiency and energy acceptance are limited and fixed by the system’s geometrical features. In order to overcome these limitations, the application of Compton cameras for SPECT has been investigated for several years. In this study we compare a commercial SPECT-Anger device, the General Electric HealthCare Infinia system with a High Energy General Purpose (HEGP) collimator, and the Compton camera prototype under development by the French collaboration CLaRyS, through Monte Carlo simulations (GATE—GEANT4 Application for Tomographic Emission—version 7.1 and GEANT4 version 9.6, respectively). Given the possible introduction of new radio-emitters at higher energies intrinsically allowed by the Compton camera detection principle, the two detectors are exposed to point-like sources at increasing primary gamma energies, from actual isotopes already suggested for nuclear medicine applications. The Compton camera prototype is first characterized for SPECT application by studying the main parameters affecting its imaging performance: detector energy resolution and random coincidence rate. The two detector performances are then compared in terms of radial event distribution, detection efficiency and final image, obtained by gamma transmission analysis for the Anger system, and with an iterative List Mode-Maximum Likelihood Expectation Maximization (LM-MLEM) algorithm for the Compton reconstruction. The results show for the Compton camera a detection efficiency increased by a factor larger than an order of magnitude with respect to the Anger camera, associated with an enhanced spatial resolution for energies beyond 500 keV. We discuss the advantages of Compton camera application

  8. Functional brain imaging study in patients with anxiety disorders using SPECT

    International Nuclear Information System (INIS)

    Sun Da; Zhan Hongwei; Liu Hongbiao; Li Huichun

    2005-01-01

    Objective: To evaluate the changes of brain function in patients with anxiety disorders. Methods: Regional cerebral perfusion was investigated using SPECT in 65 patients with anxiety disorders dragnosed according to the fourth edition of the diagnostic and statistical manual of mental disorder (DSMTD) criteria and in a matched control group of 21 healthy volunteers. 65 cases of the patients were further divided into: drug treated group (31 patients) and non-drug treated group (34 patients). The mean ages of the patients and the controls were (39.2±26.1) and (34.4±9.7) years, respectively. The severity of the anxiety was assessed using the 17-item Hamilton Anxiety scale (mean: 24.8±5.5 and 24.7±7.5, respectively). After administration of 740-925 MBq 99 Tc m -ethylene cysteinate direct (ECD) brain SPECT image study was performed. For the semi- quantitative analysis of the data, the ratios of the mean counts/pixel in the different cerebral regions of interest (ROI) to that of cerebellum were calculated respectively as a regional perfusion index (RPI). Some patients had a repeated SPECT after three months of treatment. Results: 93.8% (61/65) patients had relative hypoperfusions in some cerebral regions. Compared with the control group, the patients had a significant decrease of regional cerebral blood flow (rCBF) in the bilateral frontal lobes, paralimbic system, temporal lobes and basal ganglia. The course of disease had negatively correlated with the changes of rCBF in both groups of patients. Follow-up SPECT study demonstrated increased rCBF related with the symptomatic improvement. Conclusions: Patients with anxiety disorders had profound dysfunction of the frontal and temporal cortices, and was closely related to the symptom and therapy. 99 Tc m -ECD brain SPECT may offer the most accurate assessment of response to therapy. . (authors)

  9. The SPECT tracer [{sup 123}I]ADAM binds selectively to serotonin transporters: a double-blind, placebo-controlled study in healthy young men

    Energy Technology Data Exchange (ETDEWEB)

    Giessen, Elsmarieke van de [University of Amsterdam, Academic Medical Center, Graduate School Neurosciences Amsterdam, Department of Nuclear Medicine, Amsterdam (Netherlands); Booij, Jan [University of Amsterdam, Academic Medical Center, Graduate School Neurosciences Amsterdam, Department of Nuclear Medicine, Amsterdam (Netherlands); University of Amsterdam, Academic Medical Center, Department of Nuclear Medicine, F2-236, Amsterdam (Netherlands)

    2010-08-15

    The tracer {sup 123}I-2-([2-({l_brace}dimethylamino{r_brace}methyl)phenyl]thio)-5-iodophenylamine ([{sup 123}I]ADAM) has been developed to image serotonin transporters (SERTs) with SPECT. Preclinical studies have shown that [{sup 123}I]ADAM binds selectively to SERTs. Moreover, initial human studies have shown that [{sup 123}I]ADAM binding could be blocked by selective serotonin reuptake inhibitors (SSRIs). However, in humans it has not been proven that [{sup 123}I]ADAM binds selectively to SERTs. We examined the in vivo availability of SERTs in 12 healthy young volunteers 5 h after bolus injection of [{sup 123}I]ADAM. To evaluate the selectivity of binding, four participants were pretreated (double-blinded design) with placebo, four with paroxetine (20 mg) and four with the dopamine/norepinephrine blocker methylphenidate (20 mg). SPECT studies were performed on a brain-dedicated system (Neurofocus), and the SPECT images were coregistered with individual MR scans of the brain. ADAM binding in SERT-rich brain areas and cerebellar cortex (representing non-specific binding) was assessed by drawing regions of interest (ROIs) on the individual MR images. Specific to non-specific ratios were used as the outcome measure. We found that specific to non-specific ratios were statistically significantly lower in paroxetine-pretreated participants than in placebo- or methylphenidate-pretreated participants. No such difference was found between groups pretreated with placebo or methylphenidate. Our preliminary findings suggest that [{sup 123}I]ADAM binds selectively to SERTs in human brain. (orig.)

  10. Preclinical experimental stress studies: protocols, assessment and comparison.

    Science.gov (United States)

    Bali, Anjana; Jaggi, Amteshwar Singh

    2015-01-05

    Stress is a state of threatened homeostasis during which a variety of adaptive processes are activated to produce physiological and behavioral changes. Preclinical models are pivotal for understanding these physiological or pathophysiological changes in the body in response to stress. Furthermore, these models are also important for the development of novel pharmacological agents for stress management. The well described preclinical stress models include immobilization, restraint, electric foot shock and social isolation stress. Stress assessment in animals is done at the behavioral level using open field, social interaction, hole board test; at the biochemical level by measuring plasma corticosterone and ACTH; at the physiological level by measuring food intake, body weight, adrenal gland weight and gastric ulceration. Furthermore the comparison between different stressors including electric foot shock, immobilization and cold stressor is described in terms of intensity, hormonal release, protein changes in brain, adaptation and sleep pattern. This present review describes these preclinical stress protocols, and stress assessment at different levels. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    Science.gov (United States)

    Winant, Celeste D.; Aparici, Carina Mari; Zelnik, Yuval R.; Reutter, Bryan W.; Sitek, Arkadiusz; Bacharach, Stephen L.; Gullberg, Grant T.

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94Tc-methoxyisobutylisonitrile (94Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K1. For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99mTc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal maximum

  12. Investigation of dynamic SPECT measurements of the arterial input function in human subjects using simulation, phantom and human studies

    International Nuclear Information System (INIS)

    Winant, Celeste D; Aparici, Carina Mari; Bacharach, Stephen L; Gullberg, Grant T; Zelnik, Yuval R; Reutter, Bryan W; Sitek, Arkadiusz

    2012-01-01

    Computer simulations, a phantom study and a human study were performed to determine whether a slowly rotating single-photon computed emission tomography (SPECT) system could provide accurate arterial input functions for quantification of myocardial perfusion imaging using kinetic models. The errors induced by data inconsistency associated with imaging with slow camera rotation during tracer injection were evaluated with an approach called SPECT/P (dynamic SPECT from positron emission tomography (PET)) and SPECT/D (dynamic SPECT from database of SPECT phantom projections). SPECT/P simulated SPECT-like dynamic projections using reprojections of reconstructed dynamic 94 Tc-methoxyisobutylisonitrile ( 94 Tc-MIBI) PET images acquired in three human subjects (1 min infusion). This approach was used to evaluate the accuracy of estimating myocardial wash-in rate parameters K 1 for rotation speeds providing 180° of projection data every 27 or 54 s. Blood input and myocardium tissue time-activity curves (TACs) were estimated using spatiotemporal splines. These were fit to a one-compartment perfusion model to obtain wash-in rate parameters K 1 . For the second method (SPECT/D), an anthropomorphic cardiac torso phantom was used to create real SPECT dynamic projection data of a tracer distribution derived from 94 Tc-MIBI PET scans in the blood pool, myocardium, liver and background. This method introduced attenuation, collimation and scatter into the modeling of dynamic SPECT projections. Both approaches were used to evaluate the accuracy of estimating myocardial wash-in parameters for rotation speeds providing 180° of projection data every 27 and 54 s. Dynamic cardiac SPECT was also performed in a human subject at rest using a hybrid SPECT/CT scanner. Dynamic measurements of 99m Tc-tetrofosmin in the myocardium were obtained using an infusion time of 2 min. Blood input, myocardium tissue and liver TACs were estimated using the same spatiotemporal splines. The spatiotemporal

  13. Standard Operating Procedures (SOPs) for Evaluating the Heart in Preclinical Studies of Duchenne Muscular Dystrophy.

    Science.gov (United States)

    Duan, Dongsheng; Rafael-Fortney, Jill A; Blain, Alison; Kass, David A; McNally, Elizabeth M; Metzger, Joseph M; Spurney, Christopher F; Kinnett, Kathi

    2016-02-01

    A recent working group meeting focused on contemporary cardiac issues in Duchenne muscular dystrophy (DMD) was hosted by the National Heart, Lung, and Blood Institute in collaboration with the Parent Project Muscular Dystrophy. An outcome of this meeting was to provide freely available detailed protocols for preclinical animal studies. The goal of these protocols is to improve the quality and reproducibility of cardiac preclinical studies aimed at developing new therapeutics for the prevention and treatment of DMD cardiomyopathy.

  14. Reduced hypothalamic blood flow after radiation treatment of nasopharyngeal cancer: SPECT studies in 34 patients

    International Nuclear Information System (INIS)

    Chieng, P.U.; Huang, T.S.; Chang, C.C.; Chong, P.N.; Tien, R.D.; Su, C.T.

    1991-01-01

    To determine the effect of cranial irradiation on hypothalamic blood flow, the authors performed 44 regional cerebral blood flow studies with 99mTc hexamethyl propyleneamine oxime (HMPAO) single-photon emission CT (SPECT) on four normal volunteers and 34 patients with pathologically proved nasopharyngeal cancer. Twenty-three men and 15 women, 30-65 years old, were divided into four study groups: group 1 served as a control and consisted of four normal volunteers and six patients studied prior to cranial irradiation; group 2 patients had cranial irradiation half a year before the SPECT study (n = 12, one from group 1); group 3 patients were irradiated 1 year before the study (n = 13, three from group 1 and two from group 2); and group 4 patients were irradiated at least 5 years before SPECT imaging (n = 9). Six patients were studied twice. Quantification of the 99mTc-HMPAO brain SPECT studies was done separately by three radiologists to obtain the hypothalamus/occipital (H/O) and hypothalamus/parasagittal (H/P) ratios. Endocrinologic studies were performed in all cases and the hypothalamus-thyrotroph-thyroid, hypothalamus-gonadotroph-testis (ovary), hypothalamus-lactotroph, hypothalamus-somatotroph, and hypothalamus-corticotroph-adrenal axes were evaluated separately. They determined that regional hypothalamic blood flow was reduced after cranial irradiation in patients with nasopharyngeal cancer. The H/O ratio of groups 3 and 4 did not differ from that of group 2 (one-half year after cranial irradiation). The H/O ratio was significantly reduced 6 months and 1 year after cranial irradiation; mean ± SD = 0.5801 ± 0.0829 (p less than .025), 0.5725 ± 0.0791 (p less than .01) versus 0.6477 ± 0.0458 before cranial irradiation, respectively

  15. Task Equivalence for Model and Human-Observer Comparisons in SPECT Localization Studies

    Science.gov (United States)

    Sen, Anando; Kalantari, Faraz; Gifford, Howard C.

    2016-06-01

    While mathematical model observers are intended for efficient assessment of medical imaging systems, their findings should be relevant for human observers as the primary clinical end users. We have investigated whether pursuing equivalence between the model and human-observer tasks can help ensure this goal. A localization receiver operating characteristic (LROC) study tested prostate lesion detection in simulated In-111 SPECT imaging with anthropomorphic phantoms. The test images were 2D slices extracted from reconstructed volumes. The iterative ordered sets expectation-maximization (OSEM) reconstruction algorithm was used with Gaussian postsmoothing. Variations in the number of iterations and the level of postfiltering defined the test strategies in the study. Human-observer performance was compared with that of a visual-search (VS) observer, a scanning channelized Hotelling observer, and a scanning channelized nonprewhitening (CNPW) observer. These model observers were applied with precise information about the target regions of interest (ROIs). ROI knowledge was a study variable for the human observers. In one study format, the humans read the SPECT image alone. With a dual-modality format, the SPECT image was presented alongside an anatomical image slice extracted from the density map of the phantom. Performance was scored by area under the LROC curve. The human observers performed significantly better with the dual-modality format, and correlation with the model observers was also improved. Given the human-observer data from the SPECT study format, the Pearson correlation coefficients for the model observers were 0.58 (VS), -0.12 (CH), and -0.23 (CNPW). The respective coefficients based on the human-observer data from the dual-modality study were 0.72, 0.27, and -0.11. These results point towards the continued development of the VS observer for enhancing task equivalence in model-observer studies.

  16. The EEG, CT and Tc-99m HMPAO SPECT study in patients with epilepsy

    International Nuclear Information System (INIS)

    Tovuudorj, A.; Tsagaankhuu, G.; Onkhuudai, P.; Tsevelmaa, L.; Sereegotov, E.; Enkhtuya, B.

    2007-01-01

    Full text: We have put an objective of studying the EEG and neuroimaging diagnostic indexes (CT, SPECT) in patients with partial seizures during interictal period. Methods: In our study a total of 35 cases were included (20 male and 15 females). In EEG studies we used the diagnostics methodology elaborated by L.R.Zenkov (1996) and in SPECT study by Payne JK (1991) and in CT investigation by Chermissan V.M (2001). Results: By EEG study the cases of interictal period of partial seizure were mostly revealed in the form of sharp waves in temporal lobe (47.62.5%). By CT study the 18 (51.4 ± 2.5 %) cases of partial seizure with normal index, 12 (34.3 ± 1.8 %) cases with dilatation of ventricles and 5 (14.3 ± 2.1%) cases of cerebral atrophy. In SPECT investigation we identified 8 (22.81.8%) cases with normal brain blood flow supply and 27 (77.2 2.0%) cases with variable degrees of hypoperfusion (AI) in the temporal lobe was reaching 233.9% (p<0.01). Conclusion: 1. On EEG analysis during interictal period of partial seizures, there were prevailing sharp-waves (47.6 ± 2.5%) at temporal location of a hemispheres. 2. The brain CT investigation during epilepsy mostly revealed the normal indexes 3. By analyzing brain SPECT during the interictal period of seizures, there were prevailing hypoperfusion degrees (AI) of blood flow to reach 23.0 ± 3.9%. (author)

  17. In vivo tomographic study of cerebral blood perfusion with SPECT in hemiparkinsonian monkeys

    International Nuclear Information System (INIS)

    Chen Shengdi; Xu Delong

    1994-01-01

    The authors present data on the utility of functional brain imaging with 99m Tc-ECD and SPECT in the study of MPTP induced hemiparkinsonism in monkeys. Injection of MPTP into the right common carotid artery of 10 rhesus monkeys produced hemiparkinsonism in the contralateral limbs which responded to antiparkinsonian medication. The unilateral neurotoxicity of the MPTP treated side was confirmed biochemically by marked reduction of DA contents in the nigrostriatum and histologically by selective neuronal loss in the substantia nigra. These monkeys with hemiparkinsonism were studied with SPECT using 99m Tc-ECD as perfusion marker. The results of brain scanning showed that the cerebral blood perfusion of MPTP treated side was significantly depleted 20∼90 days after MPTP intoxication, and returned to normal 8 months after perfusion. The experiment indicates that abnormal cerebral blood perfusion is involved in the course of parkinsonian pathophysiology

  18. A comparative study of attenuation correction algorithms in single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Murase, Kenya; Itoh, Hisao; Mogami, Hiroshi; Ishine, Masashiro; Kawamura, Masashi; Iio, Atsushi; Hamamoto, Ken

    1987-01-01

    A computer based simulation method was developed to assess the relative effectiveness and availability of various attenuation compensation algorithms in single photon emission computed tomography (SPECT). The effect of the nonuniformity of attenuation coefficient distribution in the body, the errors in determining a body contour and the statistical noise on reconstruction accuracy and the computation time in using the algorithms were studied. The algorithms were classified into three groups: precorrection, post correction and iterative correction methods. Furthermore, a hybrid method was devised by combining several methods. This study will be useful for understanding the characteristics limitations and strengths of the algorithms and searching for a practical correction method for photon attenuation in SPECT. (orig.)

  19. Study of 123I-IMP SPECT on diabetic patients

    International Nuclear Information System (INIS)

    Kinoshita, Ikuo; Takeo, Goh; Iwanaga, Keisuke; Uotani, Shigeo; Nakamura, Minoru; Sohda, Masanori; Ohe, Haruto; Toshimitsu, Takashi; Ohe, Nobuharu

    1991-01-01

    The involvement of peripheral nerves and nerve roots often leads to neurological manifestations which have frequently been described in association with diabetes mellitus. Whether there is any specific involvement of the central nervous system in this process has yet to be determined. Recently, many reports have suggested that significant neurophysiologic abnormalities in the central nervous system can sometimes be found in diabetic patients. In order to accurately examine the existence of central nervous system involvement in patients with diabetes mellitus, comparisons of 123 I-IMP (IMP) washout rates were made between normal adults (n=19, average age 43.3 years) and diabetic patients (n=23, average age 43.3 years), and these results were graphically demonstrated by color images. Early images were obtained 30 minutes after intravenous injection, while delayed images were made 4 hours after injection. The IMP washout rate was obtained by subtracting the values of the delayed image with the early image. The standard deviation (SD) of the IMP washout rate for each patient was compared to the averaged SD obtained from healthy adults. After calculating the deviation from SD levels of healthy adults, we made an image of the patient's IMP washout rates. These images were divided into seven degrees (I, II: normal, III, IV: borderline, V∼VII: abnormal) and the ratio of each degree was expressed by a histogram in each cerebral hemisphere as the washout rate index. In 23 diabetic subjects, seven patients were found to be borderline while sixteen patients were abnormal. These impairments were not related either to the presence of diabetic triopathy or the duration of disease. By utilising such a noninvasive method, we were able to accurately evaluate the extent of diabetic central neuropathy. Therefore this subtraction method, which uses the specificity of IMP SPECT, is thus considered to be highly useful for broad clinical application. (author)

  20. SPECT/CT versus MRI in patients with nonspecific pain of the hand and wrist - a pilot study

    International Nuclear Information System (INIS)

    Huellner, Martin W.; Buerkert, Alexander; Schleich, Florian S.; Strobel, Klaus; Veit-Haibach, Patrick; Schuerch, Maja; Hug, Urs; Wartburg, Urs von

    2012-01-01

    Hand and wrist pain is a diagnostic challenge for hand surgeons and radiologists due to the complex anatomy of the involved small structures. The American College of Radiology recommends MRI as the study of choice in patients with chronic wrist pain if radiographs are negative. Lately, state-of-the-art SPECT/CT systems have been introduced and may help in the diagnosis of this selected indication. This retrospective study included 21 patients with nonspecific pain of the hand/wrist. The diagnosis of nonspecific wrist pain was made by the referring hand surgeon based on patient history, clinical examination, plain radiography and clinical guidelines. All patients received planar early-phase imaging and late-phase SPECT/CT imaging as well as MRI. Lesions were divided into major (causative) and minor (not causative) pathologies according to clinical follow-up. Furthermore, oedema-like bone marrow changes seen on MRI were compared with focally increased tracer uptake seen on SPECT/CT images. MRI yielded a quite high sensitivity (0.86), but a low specificity (0.20). In contrast, SPECT/CT yielded a high specificity (1.00) and a low sensitivity (0.71). Oedema-like bone marrow changes were detected in 15 lesions in 11 patients. In ten lesions with bone marrow oedema on MRI, foci of elevated tracer uptake were detected on SPECT/CT. Overall, MRI was more sensitive, but SPECT/CT was more specific in the evaluation of causative pathologies. In this initial comparison, SPECT/CT showed higher specificity than MRI in the evaluation of causative pathologies in patients with nonspecific wrist pain. However, MRI was more sensitive. Thus, SPECT/CT was shown to be a useful problem-solving tool in the diagnostic work-up of these patients. (orig.)

  1. A preliminary study of neuroSPECT evaluation of patients with post-traumatic smell impairment

    International Nuclear Information System (INIS)

    Eftekhari, Mohammad; Assadi, Majid; Kazemi, Majid; Saghari, Mohsen; Esfahani, Armaghan Fard; Sichani, Babak Fallahi; Gholamrezanezhad, Ali; Beiki, Davood

    2005-01-01

    Most olfactory testings are subjective and since they depend upon the patients' response, they are prone to false positive results. The aim of this study was to use quantitative brain perfusion SPECT in order to detect possible areas of brain activation in response to odorant stimulation in patients with post-traumatic impaired smell in comparison to a group of normal subjects. Fourteen patients with post-traumatic impaired smell and ten healthy controls were entered in this prospective study. All subjects underwent brain SPECT after intravenous injection of 740-MBq 99m Tc-ECD and 48 hours later, the same procedure was repeated following olfactory stimulus (vanilla powder). In most of seven regions of interest (Orbital Frontal Cortex, Inferior Frontal Pole, Superior Frontal Pole, Posterior Superior Frontal Lobe, Parasagittal Area, Occipital Pole, and Cerebellar area) the post-stimulation quantitative values show increased cortical perfusion being more pronounced in normal volunteers than the anosmic patients (except cerebellar areas and the right occipital pole). Maximal activation was observed in orbitofrontal regions (right+ 25.45% and left +25.47%). Brain SPECT is a valuable imaging technique in the assessment of post-traumatic anosmia and could be competitive as an alternative to other imaging techniques, especially when functional MRI is unavailable or unsuitable. However, this procedure may benefit from complementary MRI or CT anatomical imaging

  2. Multi-centre evaluation of accuracy and reproducibility of planar and SPECT image quantification. An IAEA phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, Brian E. [National Institute of Standards and Technology, Gaithersburg, MD (United States); Grosev, Darko [Univ. Hospital Centre Zagreb (Croatia); Buvat, Irene [Service Hospitalier Frederic Joliot, Paris (France); and others

    2017-08-01

    Accurate quantitation of activity provides the basis for internal dosimetry of targeted radionuclide therapies. This study investigated quantitative imaging capabilities at sites with a variety of experience and equipment and assessed levels of errors in activity quantitation in Single-Photon Emission Computed Tomography (SPECT) and planar imaging. Participants from 9 countries took part in a comparison in which planar, SPECT and SPECT with X ray computed tomography (SPECT-CT) imaging were used to quantify activities of four epoxy-filled cylinders containing {sup 133}Ba, which was chosen as a surrogate for {sup 131}I. The sources, with nominal volumes of 2, 4, 6 and 23 mL, were calibrated for {sup 133}Ba activity by the National Institute of Standards and Technology, but the activity was initially unknown to the participants. Imaging was performed in a cylindrical phantom filled with water. Two trials were carried out in which the participants first estimated the activities using their local standard protocols, and then repeated the measurements using a standardized acquisition and analysis protocol. Finally, processing of the imaging data from the second trial was repeated by a single centre using a fixed protocol. In the first trial, the activities were underestimated by about 15% with planar imaging. SPECT with Chang's first order attenuation correction (Chang-AC) and SPECT-CT overestimated the activity by about 10%. The second trial showed moderate improvements in accuracy and variability. Planar imaging was subject to methodological errors, e.g., in the use of a transmission scan for attenuation correction. The use of Chang-AC was subject to variability from the definition of phantom contours. The project demonstrated the need for training and standardized protocols to achieve good levels of quantitative accuracy and precision in a multicentre setting. Absolute quantification of simple objects with no background was possible with the strictest protocol to

  3. A new method for brain functional study using Tc-99m HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Toshimitsu; Kosaka, Noboru; Nishikawa, Junichi; Ohtake, Tohru; Watanabe, Toshiaki; Iio, Masahiro (Tokyo Univ. (Japan). Faculty of Medicine)

    1989-04-01

    The distribution of {sup 99m}Tc-HMPAO in brain is in proportion to regional cerebral blood flow (rCBF) and can be interpreted as functional mapping. To evaluate local changes in CBF during neuropsychological testing, we developed a new subtraction method using HMPAO and SPECT. With patients resting, 15 mCi of HMPAO was injected and the first acquisition was performed, lasting a total of 10 minutes. Soon after the end of the first scan, patients were requested to undergo Buschke's memory test or to repeat words or numbers (repetition test). During the task, an additional 15 mCi of HMPAO was injected using the same position as in the first scan, and a second acquisition was started. A functional image was made by subtracting the image in the first scan from that in the second. In two patients with transient global amnesia and two normal controls, Buschke's memory test was performed in combination with SPECT. A relative increase in activity was seen in the thalamus, subthalamic area, hippocampus, and some cortial areas, apparently reflecting local functional change induced by the memory task. In two patients with moderate Alzheimer's disease with severe memory loss, no increase was detected in these areas. In one patient with aphasia, the repetition test with SPECT was correlated with the WADA test and dichotic listening test, and good agreement was obtained. In conclusion, our new SPECT technique is useful in detecting alterations in rCBF during mental activity and can be applied to neurophysiological studies. (author).

  4. Decreased cerebral blood flow and prognosis of Alzheimer's disease. A multicenter HMPAO-SPECT study

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Hashikawa, Kazuo; Fukuyama, Hidenao

    2007-01-01

    The purpose of this study was to determine the usefulness of brain perfusion single photon emission computed tomography (SPECT) for evaluating the severity and progression of Alzheimer's disease (AD). Eighty-four AD patients were included. At entry, 99m Tc-HMPAO-SPECT, the Mini Mental State Examination (MMSE), Mental Function Impairment Scale (MENFIS), and the Raven Colored Progression Matrix (RCPM) were performed for all 84 patients. During the follow-up periods, two individual MMSE evaluations in 34 patients, two MENFIS evaluations in 30 patients, and two RCPM evaluations in 20 patients were performed. Based on the regions of decreased cerebral blood flow demonstrated on three-dimensional stereotactic surface projection (3D-SSP) images of SPECT, the cases were classified as type A (no decrease), type B (decreased blood flow in the parietal or temporal lobe), type C (decreased blood flow in the frontal lobe and parietal or temporal lobe), type Pc (decreased blood flow in posterior cingulate gyrus only), and ''other types''. The types of decreased blood flow, scores on neuropsychological evaluations, and symptom progression were analyzed. The MENFIS, MMSE, and RCPM scores were poorest in type C patients at entry. The degree of decrease of these scores during the follow-up periods was also greatest in type C. The greatest difference between patients with and without rapid progression in SPECT data of the mild AD patients (MMSE score≥24) was in the frontal lobe. Decreased blood flow in the frontal lobe of AD patients is correlated not only with reduced cognitive function at the time of the evaluation but with rapid progression in the subsequent clinical course. (author)

  5. Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study

    Directory of Open Access Journals (Sweden)

    Banari Bahnamiri Sh

    2015-03-01

    Full Text Available Background: Obtaining high quality images in Single Photon Emission Tomography (SPECT device is the most important goal in nuclear medicine. Because if image quality is low, the possibility of making a mistake in diagnosing and treating the patient will rise. Studying effective factors in spatial resolution of imaging systems is thus deemed to be vital. One of the most important factors in SPECT imaging in nuclear medicine is the use of an appropriate collimator for a certain radiopharmaceutical feature in order to create the best image as it can be effective in the quantity of Full Width at Half Maximum (FWHM which is the main parameter in spatial resolution. Method: In this research, the simulation of the detector and collimator of SPECT imaging device, Model HD3 made by Philips Co. and the investigation of important factors on the collimator were carried out using MCNP-4c code. Results: The results of the experimental measurments and simulation calculations revealed a relative difference of less than 5% leading to the confirmation of the accuracy of conducted simulation MCNP code calculation. Conclusion: This is the first essential step in the design and modelling of new collimators used for creating high quality images in nuclear medicine

  6. Quantification of 99mTc-MIBI lung uptake in myocardial SPECT studies

    International Nuclear Information System (INIS)

    Qu Wanying; Lu Zhenping; Zhou Ying; He Qin

    1996-01-01

    To assess the significance of 99m Tc-MIBI lung uptake during myocardial SPECT studies in the evaluation of left ventricular dysfunction. 42 control subjects and 65 patients with coronary artery disease (CAD) were investigated with 99m Tc-MIBI myocardial SPECT and radionuclide ventriculography (RNV) within 1 week. The lung-to-heart ratios (LHR) both at rest and exercise were calculated from the anterior projection of the SPECT image sets. The left ventricular ejection fraction (LVEF) was determined using RNV. In the control group, a significant decrease in LHR was observed during exercise (P<0.01). The CAD group showed significantly high LHR values both at rest and exercise. A negative correlation was observed between LHR values and LVEF at rest (r -0.6234, P<0.001) and exercise (r = -0.6113, P<0.001). LHR both at rest and exercise are significantly correlated with LVEF and may be useful in the evaluation of left ventricular function

  7. Dopamine transporter imaging with [I-123]IPT SPECT in normal controls and Parkinson's patients: Feasibility study of a simplified SPECT scan protocol

    International Nuclear Information System (INIS)

    Kim, H. J.; Bong, J. K.; Nam, K. P.; Yang, S. O.; Moon, D. H.; Ryu, J. S.; Lee, H. K.

    1997-01-01

    [I-123]IPT has been used to measure changes in dopamine trasnporters with Parkinson's patients (PP). However, 2 hrs of imaging time without movement of patient's head partially limits its widespread use in routine clinical SPECT protocol. The purpose of this study was to evaluate the feasibility of a simplified IPT SPECT scan protocol using three 10 min scan data obtained at 0-10, 55-65, and 110-120 min postinjection and compared to current protocol using 23 scans obtained from O-120 min to quantify dopamine transporter binding in normal controls (NC) and PP. IPT labeled with 6.74±0.88mCi of I-123 was intravenously injected into 12 NC (age: 41±9) and 22 PP (age : 55±8) and the 5 min dynamic SPECT data were acquired for 2 hrs with Trionix triple-headed SPECT camera. SPECT images were reconstructed and attenuation corrected. [I-123] IPT quickly penetratd the blood-brain barrier and began to Ioacalize higher concentrations at the basal ganglia at 20 min after injection. The transporter parameter was measured using a variation of graphical analysis (VGA) and area ratio method (ARM) that derive the distribution volume ratios (R v =V 3 /V 2 for VGA, R A =V 3 /V 2 for ARM ) from multiple scan data without blood data, R v ' and R A ' measured from three 10 min scan data and compared with R v and R A measured from 23 scans for both NC and PP, (R v ', R v ') or NC and PP were (1.83±0.29, 2.21±0.34) and (0.63±0.34, 0.77±0.31), respectively. (R v ', R A ) for NC and PP were (1.11±0.22, 1.62±0.28) and (0.43±0.21, 0.65±0.24), respectively, Both (R v ', R v ) and (R A ', R A ) for NC were clearly separated from those for PP. R' v and R' A underestimated R v and R A by 18.4% and 33.5%, respectively, but R v ' and R A ' showed excellent correlations with R v (r=0.95) and R A (r=0.97), respectively. The results indicate that the three 10 min scan protocol may be feasible and allows us to differentiate dopamine transporter parameters in PP from those in NC

  8. The effect of learning styles and study behavior on success of preclinical students in pharmacology.

    Science.gov (United States)

    Asci, Halil; Kulac, Esin; Sezik, Mekin; Cankara, F Nihan; Cicek, Ekrem

    2016-01-01

    To evaluate the effect of learning styles and study behaviors on preclinical medical students' pharmacology exam scores in a non-Western setting. Grasha-Reichmann Student Learning Study Scale and a modified Study Behavior Inventory were used to assess learning styles and study behaviors of preclinical medical students (n = 87). Logistic regression models were used to evaluate the independent effect of gender, age, learning style, and study behavior on pharmacology success. Collaborative (40%) and competitive (27%) dominant learning styles were frequent in the cohort. The most common study behavior subcategories were study reading (40%) and general study habits (38%). Adequate listening and note-taking skills were associated with pharmacology success, whereas students with adequate writing skills had lower exam scores. These effects were independent of gender. Preclinical medical students' study behaviors are independent predictive factors for short-term pharmacology success.

  9. Functional brain imaging with SPECT in normal again and dementia. Methodological, pathophysiological, and diagnostic aspects

    International Nuclear Information System (INIS)

    Waldemar, G.

    1996-03-01

    New developments in instrumentation, radiochemistry, and data analysis, particularly the introduction of 99m Tc-labeled brain-retained tracers for perfusion studies, have opened up a new era of single photon emission computed tomography (SPECT). In this review critical methodological issues relating to the SPECT instrument, the radioactive tracers, the scanning procedure, the data analysis and interpretation of data, and subject selection are discussed together with the changes in regional cerebral blood flow (rCBF) observed in normal aging. An overview is given of the topography and the pathophysiological and diagnostic significance of focal rCBF deficits in Alzheimer's disease and in other dementia disorders, in which SPECT is capable of early or preclinical disease detection. In Alzheimer's disease, the diagnostic sensitivity and specificity of focal rCBF deficits measured with SPECT and brain-retained tracers are very high, in particular when combined with medial temporal lob atrophy on CT. Together with neuropsychological testing, SPECT serves to map the topography of brain dysfunction. Thus, in the clinical setting, SPECT provides information that is supplemental to that obtained in other studies. Future applications include neuroreceptor studies and treatment studies, in which SPECT may serve as a diagnostic aid in the selection of patients and as a potential mean for monitoring treatment effects. Although positron emission tomography is the best characterized tool for addressing some of these clinical and research issues in dementia, only the less expensive and technically simpler SPECT technique will have the potential of being available as a screening diagnostic instrument in the clinical setting. It is concluded that, properly approached, functional brain imaging with SPECT represents an important tool in the diagnosis, management, and research of dementia disorders. (au) 251 refs

  10. A clinical study of thallium-201 SPECT in the diagnostic imaging of oral squamous cell carcinomas

    International Nuclear Information System (INIS)

    Satoh, Hitoshi

    2003-01-01

    Recently the usefulness of thallium 201 chloride (201Tl) as a tumor imaging agent for various tumors has been reported. However, the application of 201Tl SPECT to oral squamous cell carcinomas has not been established. The purpose of this study is to investigate the usefulness of 201Tl SPECT in the assessment of malignancy or in the differential diagnosis of oral squamous cell carcinomas from inflammatory diseases. Thirty-two patients with 33 primary oral squamous cell carcinomas and 4 patients with inflammatory disease were studied. SPECT images were acquired 15 minutes (early image) and 3 hours (delayed image) after the intravenous injection with 74 MBq 201Tl, and then early uptake ratio (ER), delayed uptake ratio (DR), and retention index (RI) were measured. The relations between these parameters and the size, the site, the degree of differentiation and the mode of invasion of the primary tumor were analyzed statistically. 201Tl SPECT correctly identified 32 of the 33 tumors, with 32 patients having oral squamous cell carcinoma, making the positive rate 97%. Significant negative correlation was observed between RI and major or minor axis of tumors; therefore, this study revealed that RI was influenced by the size of a tumor. In comparison with the average value of RI according to histopathological diagnosis, there was statistically significant difference (p=0.011) between carcinomas (0.80±0.16, n=30) and inflammatory diseases (0.58±0.04, n=4); thus, it was supposed that differential diagnosis between them could be possible. About the tumors with the range of minor-axis 20 mm-40 mm for little influence of tumor size to the RI, the tendency to decrease for the RI of well-differentiated group or low-invasive group was seen. For oral squamous cell carcinomas, 201Tl SPECT had a high positive rate. The application was suggested for use in the differential diagnosis between inflammatory disease and carcinomas, where clinical usefulness could be expected. (author)

  11. Reproducibility of preclinical animal research improves with heterogeneity of study samples

    Science.gov (United States)

    Vogt, Lucile; Sena, Emily S.; Würbel, Hanno

    2018-01-01

    Single-laboratory studies conducted under highly standardized conditions are the gold standard in preclinical animal research. Using simulations based on 440 preclinical studies across 13 different interventions in animal models of stroke, myocardial infarction, and breast cancer, we compared the accuracy of effect size estimates between single-laboratory and multi-laboratory study designs. Single-laboratory studies generally failed to predict effect size accurately, and larger sample sizes rendered effect size estimates even less accurate. By contrast, multi-laboratory designs including as few as 2 to 4 laboratories increased coverage probability by up to 42 percentage points without a need for larger sample sizes. These findings demonstrate that within-study standardization is a major cause of poor reproducibility. More representative study samples are required to improve the external validity and reproducibility of preclinical animal research and to prevent wasting animals and resources for inconclusive research. PMID:29470495

  12. Is 16-frame really superior to 8-frame gated SPECT for the assessment of left ventricular volumes and ejection fraction? Comparison of two simultaneously acquired gated SPECT studies

    International Nuclear Information System (INIS)

    Montelatici, Giulia; Sciagra, Roberto; Passeri, Alessandro; Dona, Manjola; Pupi, Alberto

    2008-01-01

    Conflicting data exist about the difference between 8- and 16-frame gated single-photon emission computed tomography (SPECT) left ventricular volumes and ejection fraction (EF); moreover, the influence of framing on detection of stress-induced functional changes is unknown. In 133 patients, two separate gated SPECT studies, one with 8 and one with 16 frames, were simultaneously acquired during a single gantry orbit using dedicated software. In 33 of 133 patients, two additional studies (with 8 and 16 frames, respectively) were acquired using arrhythmia rejection. Left ventricular EF and volumes were calculated using the QGS software. Stress-induced ischemia was identified on summed perfusion images. Arrhythmia-rejection did not influence volumes and EF independently of framing rate. Using data without arrhythmia-rejection, there was a significant difference in volumes and EF between 8 and 16 frames both in resting and post-stress gated SPECT. However, the difference was small: 2.6% for resting and 2.8% for post-stress EF. Both using 8 and 16 frames, there were significantly larger volumes and lower EF in patients with than without stress-induced ischemia. A stress-induced decrease >5 EF units was observed in 26 of 133 patients using 8 and in 23 of 133 using 16 frames, respectively, with finding agreement in 19 patients. Comparing two simultaneously acquired studies, the use of 16 instead of 8 frames has minor and predictable influence on functional data. Furthermore, there are no differences in the detection of stress-induced functional changes. The advantage of 16 over 8 frames in the daily clinical practice appears questionable. (orig.)

  13. Interictal Spect with Tc-99m ECD studies in migraine patients. Role of Spect in the diagnosis of migraine with ura in headache-free periods

    International Nuclear Information System (INIS)

    Gonzalez, F.M.; Martinez, J.J.; Bermudez, M.C.; Fernandez, B.; Delgado, J.; Martin, A.; Padilla, O.; Nieto, R.

    2002-01-01

    Aim: The migraine is one of the neurological alterations more frequent provoking a discharge morbility and big inconveniences the one that endures it. The presence of brain perfusion abnormalities during the pain-free intervals of migraine even is fueling of controversies being so numerous the supporters of its existence as whom they deny it. This study was aimed at assessing the presence of cerebral perfusion abnormalities also during the interictal phase and the role of SPECT with Tc99 ECD on diagnosis of this migrainous patients. Materials And Methods: We studied 20 patients (16 woman and 4 man) with diagnose of migraine with aura during a periods without headache and 20 apareaded controls for age and sex of this patients.Was realized brain spect with 925 MBq Tc99m-ECD on a two heads rotating gamma camera (Piker Axis) equipped with a fan-beam collimator. The images were reconstructed using a filter Mezt and presented in courts in the three axes and reconstruction in three dimensions and later they were analyzed by two observers. Results: We found 14 of the patients (70%) with images of focal hypoperfusion with clear interhemispheric asymmetry while on control groups only two have this find (10%) being this difference statistically significant. The part of the brain more affected was the occipital one, though also they predominated over the more widespread hipocaptations. Conclusion: The brain Spect is a useful technology to identify the patients with migraine, being able to be used in the periods without pain. The boss of perfusion in the patients is the located hypoperfusion and is significantly different from that of the controls, It can be explained by an impaired regional cerebral vascular autoregulation may exist even during headache-free intervals in patients suffering from migraine. Future studies must be realized to determine if it exists relation between the zone of hypoperfusion and the type of present symptomatology in the aura

  14. Novel epigenetic target therapy for prostate cancer: a preclinical study.

    Directory of Open Access Journals (Sweden)

    Ilaria Naldi

    Full Text Available Epigenetic events are critical contributors to the pathogenesis of cancer, and targeting epigenetic mechanisms represents a novel strategy in anticancer therapy. Classic demethylating agents, such as 5-Aza-2'-deoxycytidine (Decitabine, hold the potential for reprograming somatic cancer cells demonstrating high therapeutic efficacy in haematological malignancies. On the other hand, epigenetic treatment of solid tumours often gives rise to undesired cytotoxic side effects. Appropriate delivery systems able to enrich Decitabine at the site of action and improve its bioavailability would reduce the incidence of toxicity on healthy tissues. In this work we provide preclinical evidences of a safe, versatile and efficient targeted epigenetic therapy to treat hormone sensitive (LNCap and hormone refractory (DU145 prostate cancers. A novel Decitabine formulation, based on the use of engineered erythrocyte (Erythro-Magneto-Hemagglutinin Virosomes, EMHVs drug delivery system (DDS carrying this drug, has been refined. Inside the EMHVs, the drug was shielded from the environment and phosphorylated in its active form. The novel magnetic EMHV DDS, endowed with fusogenic protein, improved the stability of the carried drug and exhibited a high efficiency in confining its delivery at the site of action in vivo by applying an external static magnetic field. Here we show that Decitabine loaded into EMHVs induces a significant tumour mass reduction in prostate cancer xenograft models at a concentration, which is seven hundred times lower than the therapeutic dose, suggesting an improved pharmacokinetics/pharmacodynamics of drug. These results are relevant for and discussed in light of developing personalised autologous therapies and innovative clinical approach for the treatment of solid tumours.

  15. Novel epigenetic target therapy for prostate cancer: a preclinical study.

    Science.gov (United States)

    Naldi, Ilaria; Taranta, Monia; Gherardini, Lisa; Pelosi, Gualtiero; Viglione, Federica; Grimaldi, Settimio; Pani, Luca; Cinti, Caterina

    2014-01-01

    Epigenetic events are critical contributors to the pathogenesis of cancer, and targeting epigenetic mechanisms represents a novel strategy in anticancer therapy. Classic demethylating agents, such as 5-Aza-2'-deoxycytidine (Decitabine), hold the potential for reprograming somatic cancer cells demonstrating high therapeutic efficacy in haematological malignancies. On the other hand, epigenetic treatment of solid tumours often gives rise to undesired cytotoxic side effects. Appropriate delivery systems able to enrich Decitabine at the site of action and improve its bioavailability would reduce the incidence of toxicity on healthy tissues. In this work we provide preclinical evidences of a safe, versatile and efficient targeted epigenetic therapy to treat hormone sensitive (LNCap) and hormone refractory (DU145) prostate cancers. A novel Decitabine formulation, based on the use of engineered erythrocyte (Erythro-Magneto-Hemagglutinin Virosomes, EMHVs) drug delivery system (DDS) carrying this drug, has been refined. Inside the EMHVs, the drug was shielded from the environment and phosphorylated in its active form. The novel magnetic EMHV DDS, endowed with fusogenic protein, improved the stability of the carried drug and exhibited a high efficiency in confining its delivery at the site of action in vivo by applying an external static magnetic field. Here we show that Decitabine loaded into EMHVs induces a significant tumour mass reduction in prostate cancer xenograft models at a concentration, which is seven hundred times lower than the therapeutic dose, suggesting an improved pharmacokinetics/pharmacodynamics of drug. These results are relevant for and discussed in light of developing personalised autologous therapies and innovative clinical approach for the treatment of solid tumours.

  16. Tissue Engineering of the Urethra: A Systematic Review and Meta-analysis of Preclinical and Clinical Studies.

    Science.gov (United States)

    Versteegden, Luuk R M; de Jonge, Paul K J D; IntHout, Joanna; van Kuppevelt, Toin H; Oosterwijk, Egbert; Feitz, Wout F J; de Vries, Rob B M; Daamen, Willeke F

    2017-10-01

    Urethra repair by tissue engineering has been extensively studied in laboratory animals and patients, but is not routinely used in clinical practice. To systematically investigate preclinical and clinical evidence of the efficacy of tissue engineering for urethra repair in order to stimulate translation of preclinical studies to the clinic. A systematic search strategy was applied in PubMed and EMBASE. Studies were independently screened for relevance by two reviewers, resulting in 80 preclinical and 23 clinical studies of which 63 and 13 were selected for meta-analysis to assess side effects, functionality, and study completion. Analyses for preclinical and clinical studies were performed separately. Full circumferential and inlay procedures were assessed independently. Evaluated parameters included seeding of cells and type of biomaterial. Meta-analysis revealed that cell seeding significantly reduced the probability of encountering side effects in preclinical studies. Remarkably though, cells were only sparsely used in the clinic (4/23 studies) and showed no significant reduction of side effects. ln 21 out of 23 clinical studies, decellularized templates were used, while in preclinical studies other biomaterials showed promising outcomes as well. No direct comparison to current clinical practice could be made due to the limited number of randomized controlled studies. Due to a lack of controlled (pre)clinical studies, the efficacy of tissue engineering for urethra repair could not be determined. Meta-analysis outcome measures were similar to current treatment options described in literature. Surprisingly, it appeared that favorable preclinical results, that is inclusion of cells, were not translated to the clinic. Improved (pre)clinical study designs may enhance clinical translation. We reviewed all available literature on urethral tissue engineering to assess the efficacy in preclinical and clinical studies. We show that improvements to (pre)clinical study

  17. Preliminary study on the head-injury by using SPECT with 99mTc-HMPAO

    International Nuclear Information System (INIS)

    Guan Yihui; Liu Yongchang; Lin Xiangtong

    1994-01-01

    After the acute period of head trauma some cases of patients may have some symptoms, such as headache, poor memory, vertigo, et al. In this study, among 42 patients most of whom had normal CT or MRI abnormal findings of brain perfusion imaging were seen in 33 patients (78.6%). Multiple perfusion defects were observed in some patients (13/42). These indicate that the head-injury syndrome is closely related to brain blood perfusion. authors' conclusion is that the brain SPECT is able to find out the etiology of head injury syndrome

  18. A clinical study in elderly patients with Parkinson's disease using MRI and SPECT

    International Nuclear Information System (INIS)

    Umahara, Takahiko; Iwamoto, Toshihiko; Takasaki, Masaru; Katsunuma, Hideyo

    1991-01-01

    Parkinson's disease (PD) is often associated with dementia in elderly patients, and sometimes PD coexists with senile dementia of the Alzheimer type (SDAT) or cerebrovascular disease (CVD) in the elderly. However, since there are few previous clinical studies on the coincidence of, or relationship between PD and CVD, the authors evaluated these aspects in 34 elderly patients with PD using MRI and SPECT. All the patients were over 70 years old. The diagnosis of PD was based on the presence of three symptons (resting tremor, cogwheel rigidity and bradikinesia) which are characteristic of PD, and the effectiveness of L-DOPA therapy. We therefore believe that patients with vascular Parkinsonism were excluded from our study. In 34 cases, 24 (71%) had MRI evidence of CVD (mainly the lacunar state). In the 10 cases who had no CVD, 2 (20%) had severe dementia and the decrease of regional cerebral blood flow (rCBF) in the temporal and parietal lobes bilaterally correlated with the SPECT findings commonly found in SDAT. A comparison of the rCBF and the results of Hasegawa's dementia score (HDS) (verbal intelligence score) was made between the patients with PD associated with CVD and the patients with PD who had no CVD and no SPECT findings which correlated with SDAT. The rCBF in the frontal lobes and the results of the HDS of the former group were significantly lower than those of the latter. As mentioned above, elderly patients with PD often had CVD, leading to dementia. We also pointed out the difficulty in making a differential diagnosis between PD with CVD and vascular Parkinsonism, and the necessity of whether or not the concept of 'mixed type Parkinsonism' should be considered. (author)

  19. Perfusion SPECT studies with mapping of Brodmann areas in differentiating Alzheimer's disease from frontotemporal degeneration syndromes.

    Science.gov (United States)

    Valotassiou, Varvara; Papatriantafyllou, John; Sifakis, Nikolaos; Tzavara, Chara; Tsougos, Ioannis; Kapsalaki, Eftychia; Hadjigeorgiou, George; Georgoulias, Panagiotis

    2012-12-01

    The aim of this study was to evaluate the contribution of brain perfusion single-photon emission computed tomography (SPECT) studies with mapping of Brodmann areas (BAs) in the differential diagnosis between Alzheimer's disease (AD) and frontotemporal degeneration (FTLD) syndromes. Thirty-nine patients with AD and 73 patients with FTLD syndromes [behavioural variant FTLD (bvFTLD); language variant FTLD (lvFTLD), including semantic dementia (SD) and progressive nonfluent aphasia (PNFA); and corticobasal degeneration (CBD)/progressive supranuclear palsy (PSP) syndromes] underwent brain perfusion SPECT. The NeuroGam software was used for the semiquantitative evaluation of perfusion in BAs of the left (L) and right (R) hemispheres. Compared with those in AD patients, BAs with statistically significant hypoperfusion were found in the prefrontal, orbitofrontal and cingulated cortices and Broca's areas of FTLD and bvFTLD patients; in the temporal and prefrontal cortices and Broca's areas of lvFTLD patients; in the left temporal gyrus of SD patients; in premotor and supplementary motor, prefrontal, orbitofrontal, temporal and anterior cingulated cortices and Broca's areas of PNFA patients; and in the prefrontal, temporal, posterior cingulated and primary and secondary visual cortices of CBD/PSP patients. BA 46R could differentiate AD patients from FTLD and bvFTLD patients; 21L and 25L were found to be independent predictors for lvFTLD in comparison with AD, and 25R, 21L and 23R could differentiate AD patients from PNFA, SD and CBD/PSP patients, respectively. Brain perfusion SPECT with BA mapping in AD and FTLD patients could improve the definition of brain areas that are specifically implicated in these disorders, resulting in a more accurate differential diagnosis.

  20. Optimisation of quantitative lung SPECT applied to mild COPD: a software phantom simulation study.

    Science.gov (United States)

    Norberg, Pernilla; Olsson, Anna; Alm Carlsson, Gudrun; Sandborg, Michael; Gustafsson, Agnetha

    2015-01-01

    The amount of inhomogeneities in a (99m)Tc Technegas single-photon emission computed tomography (SPECT) lung image, caused by reduced ventilation in lung regions affected by chronic obstructive pulmonary disease (COPD), is correlated to disease advancement. A quantitative analysis method, the CVT method, measuring these inhomogeneities was proposed in earlier work. To detect mild COPD, which is a difficult task, optimised parameter values are needed. In this work, the CVT method was optimised with respect to the parameter values of acquisition, reconstruction and analysis. The ordered subset expectation maximisation (OSEM) algorithm was used for reconstructing the lung SPECT images. As a first step towards clinical application of the CVT method in detecting mild COPD, this study was based on simulated SPECT images of an advanced anthropomorphic lung software phantom including respiratory and cardiac motion, where the mild COPD lung had an overall ventilation reduction of 5%. The best separation between healthy and mild COPD lung images as determined using the CVT measure of ventilation inhomogeneity and 125 MBq (99m)Tc was obtained using a low-energy high-resolution collimator (LEHR) and a power 6 Butterworth post-filter with a cutoff frequency of 0.6 to 0.7 cm(-1). Sixty-four reconstruction updates and a small kernel size should be used when the whole lung is analysed, and for the reduced lung a greater number of updates and a larger kernel size are needed. A LEHR collimator and 125 (99m)Tc MBq together with an optimal combination of cutoff frequency, number of updates and kernel size, gave the best result. Suboptimal selections of either cutoff frequency, number of updates and kernel size will reduce the imaging system's ability to detect mild COPD in the lung phantom.

  1. Significance of postoperative crossed cerebellar hypoperfusion in patients with cerebral hyperperfusion following carotid endarterectomy: SPECT study

    Energy Technology Data Exchange (ETDEWEB)

    Ogasawara, Kuniaki; Kobayashi, Masakazu; Suga, Yasunori; Chida, Kohei; Saito, Hideo; Komoribayashi, Nobukazu; Otawara, Yasunari; Ogawa, Akira [Iwate Medical University, Department of Neurosurgery, Morioka (Japan); Iwate Medical University, Cyclotron Research Center, Morioka (Japan)

    2008-01-15

    Cerebral hyperperfusion after carotid endarterectomy (CEA) results in cerebral hyperperfusion syndrome and cognitive impairment. The goal of the present study was to clarify the clinical significance of postoperative crossed cerebellar hypoperfusion (CCH) in patients with cerebral hyperperfusion after CEA by assessing brain perfusion with single-photon emission computed tomography (SPECT). Brain perfusion was quantitatively measured using SPECT and the [{sup 123}I]N-isopropyl-p-iodoamphetamine-autoradiography method before and immediately after CEA and on the third postoperative day in 80 patients with ipsilateral internal carotid artery stenosis ({>=}70%). Postoperative CCH was determined by differences between asymmetry of perfusion in bilateral cerebellar hemispheres before and after CEA. Neuropsychological testing was also performed preoperatively and at the first postoperative month. Eleven patients developed cerebral hyperperfusion (cerebral blood flow increase of {>=}100% compared with preoperative values) on SPECT imaging performed immediately after CEA. In seven of these patients, CCH was observed on the third postoperative day. All three patients with hyperperfusion syndrome exhibited cerebral hyperperfusion and CCH on the third postoperative day and developed postoperative cognitive impairment. Of the eight patients with asymptomatic hyperperfusion, four exhibited CCH despite resolution of cerebral hyperperfusion on the third postoperative day, and three of these patients experienced postoperative cognitive impairment. In contrast, four patients without postoperative CCH did not experience postoperative cognitive impairment. The presence of postoperative CCH with concomitant cerebral hyperperfusion reflects the development of hyperperfusion syndrome. Further, the presence of postoperative CCH in patients with cerebral hyperperfusion following CEA suggests development of postoperative cognitive impairment, even when asymptomatic. (orig.)

  2. Significance of postoperative crossed cerebellar hypoperfusion in patients with cerebral hyperperfusion following carotid endarterectomy: SPECT study

    International Nuclear Information System (INIS)

    Ogasawara, Kuniaki; Kobayashi, Masakazu; Suga, Yasunori; Chida, Kohei; Saito, Hideo; Komoribayashi, Nobukazu; Otawara, Yasunari; Ogawa, Akira

    2008-01-01

    Cerebral hyperperfusion after carotid endarterectomy (CEA) results in cerebral hyperperfusion syndrome and cognitive impairment. The goal of the present study was to clarify the clinical significance of postoperative crossed cerebellar hypoperfusion (CCH) in patients with cerebral hyperperfusion after CEA by assessing brain perfusion with single-photon emission computed tomography (SPECT). Brain perfusion was quantitatively measured using SPECT and the [ 123 I]N-isopropyl-p-iodoamphetamine-autoradiography method before and immediately after CEA and on the third postoperative day in 80 patients with ipsilateral internal carotid artery stenosis (≥70%). Postoperative CCH was determined by differences between asymmetry of perfusion in bilateral cerebellar hemispheres before and after CEA. Neuropsychological testing was also performed preoperatively and at the first postoperative month. Eleven patients developed cerebral hyperperfusion (cerebral blood flow increase of ≥100% compared with preoperative values) on SPECT imaging performed immediately after CEA. In seven of these patients, CCH was observed on the third postoperative day. All three patients with hyperperfusion syndrome exhibited cerebral hyperperfusion and CCH on the third postoperative day and developed postoperative cognitive impairment. Of the eight patients with asymptomatic hyperperfusion, four exhibited CCH despite resolution of cerebral hyperperfusion on the third postoperative day, and three of these patients experienced postoperative cognitive impairment. In contrast, four patients without postoperative CCH did not experience postoperative cognitive impairment. The presence of postoperative CCH with concomitant cerebral hyperperfusion reflects the development of hyperperfusion syndrome. Further, the presence of postoperative CCH in patients with cerebral hyperperfusion following CEA suggests development of postoperative cognitive impairment, even when asymptomatic. (orig.)

  3. Reduced brain perfusion in basal forebrain associated with cognitive decline in Alzheimer's diseases: a Tc-99m HMPAO SPECT study

    International Nuclear Information System (INIS)

    Lee, M.C.; Kang, H.; Kang, E.; Lee, J.S.; Lee, D.S.; Lee, D.W.; Cho, M.J.

    2002-01-01

    Aim: Reduction of regional cerebral blood flow (rCBF) in various cerebral regions and decline of cognitive function have been reported in Alzheimer's disease (AD) patients. The aim of this study was to identify the brain areas showing correlation between longitudinal changes of rCBFs and decline of general mental function, measured by Mini-Mental State Examination (MMSE) in probable Alzheimer's disease patients. Materials and Methods: Nine probable AD patients according to NINCDS-ADRDA criteria and DSM-IV were studied with Tc-99m HMPAO SPECT at an initial point and at the follow-up after a period of average 1.8 year. MMSE score was obtained in both occasions (average MMSE 16.4 at initial study; average MMSE = 8.1 at follow-up). Single SPECT was performed in 30 age-matched normal controls. Each SPECT image was normalized to the cerebellar activity. Using statistical parametric mapping (SPM99), correlation was analyzed between individual changes in rCBF of two SPECT scans and the MMSE scores at the time of each study in AD patients. In addition, the SPECT images of the initial study and the follow-up study were compared with SPECT images of the age-matched normal group respectively. Results: Significant correlation between longitudinal changes of rCBFs and MMSE scores was found in left basal forebrain region including substantia innominata (x, y, z = -24, 16, -23; P < .05, corrected). Within a short follow-up period of 1.8 years, cerebral hypoperfusion extended to various cortical regions from bilateral temporo-parietal to bilateral frontal regions and cingulate cortex, compared to normal controls. Conclusion: The decline of cognitive function in individual AD patients was correlated with rCBF reduction in left basal forebrain. This finding supports the cholinergic hypothesis of AD since hypoperfusion in basal forebrain region might indicate deterioration of cholinergic neurons in nucleus basalis of Meynert or substantia innominata

  4. 123I-IMP single photon emission computed tomography (SPECT) study in childhood epilepsy

    International Nuclear Information System (INIS)

    Hara, Masafumi; Shimomura, Osamu; Kojima, Akihiro; Izunaga, Hiroshi; Tomiguchi, Seiji; Hirota, Yoshihisa; Taku, Keiichi; Miike, Teruhisa; Takahashi, Mutsumasa

    1990-01-01

    N-isopropyl-p[ 123 I]-iodoamphetamine (IMP) single photon emission computed tomography (SPECT), X-ray computed tomography (X-CT) and magnetic resonance imaging (MRI) were performed in 18 children with idiopathic seizures. In children with idiopathic seizures SPECT identified abnormal lesions in the highest rate (50%) compared with X-CT (11%) and MRI (13%), but the findings of SPECT poorly correlated with the foci on electroencephalography (EEG). Idiopathic epilepsy with abnormal uptake on SPECT was refractory to medical treatments and frequently associated with mental and/or developmental retardation. Perfusion defects identified on SPECT probably influenced the development of the brains in children. IMP SPECT is useful in the diagnosis and medical treatment in children with seizures. (author)

  5. Cerebral blood flow and volume in sympton-free migraineurs: A SPECT study

    International Nuclear Information System (INIS)

    Maini, C.L.; Turco, G.L.; Castellano, G.; Podio, V.; Cornaglia, G.; Liboni, W.; Chianale, G.

    1990-01-01

    Both CBF and BCV were evaluated by gamma-camera SPECT in 14 patients with classic migraine, all studied while symptom-free. Nuclear data were correlated with CT and MRI. A decreased regional CBF was observed in 13 of the 14 patients. The decreased perfusion was localized in the frontal lobe in 6 patients, the temporal lobe in one, the parietal lobe in 11 and the occipital lobe in 5 patients. The parieto-occipital cortex was involved more often than the frontal cortex; the association of hypoperfusion with parieto-occipital cortex was quite high. The right parieto-occipital regions were affected more often than the left ones. Regional CBV was increased in 8 patients. There was good topographical concordance between decreased CBF and increased CBV, but the increase of CBV was in general more evident at the periphery of the hypoperfusion. It is of interest that the only patient with a normal CBF study had a pathological CBV study. Apparently, CBF derangements are very common in symptom-free patients with classic migraine, a CBF decrease being often accompanied by a CBV increase. In these patients both CT and MRI have a lower diagnostic yield than SPECT. (orig.) [de

  6. Cerebral blood flow and volume in sympton-free migraineurs: A SPECT study

    Energy Technology Data Exchange (ETDEWEB)

    Maini, C.L. (Ancona Univ. (Italy). Chair of Nuclear Medicine); Turco, G.L.; Castellano, G.; Podio, V.; Cornaglia, G. (Turin Univ. (Italy). Chair of Nuclear Medicine); Liboni, W.; Chianale, G. (Turin Univ. (Italy). Dept. of Neurology)

    1990-11-01

    Both CBF and BCV were evaluated by gamma-camera SPECT in 14 patients with classic migraine, all studied while symptom-free. Nuclear data were correlated with CT and MRI. A decreased regional CBF was observed in 13 of the 14 patients. The decreased perfusion was localized in the frontal lobe in 6 patients, the temporal lobe in one, the parietal lobe in 11 and the occipital lobe in 5 patients. The parieto-occipital cortex was involved more often than the frontal cortex; the association of hypoperfusion with parieto-occipital cortex was quite high. The right parieto-occipital regions were affected more often than the left ones. Regional CBV was increased in 8 patients. There was good topographical concordance between decreased CBF and increased CBV, but the increase of CBV was in general more evident at the periphery of the hypoperfusion. It is of interest that the only patient with a normal CBF study had a pathological CBV study. Apparently, CBF derangements are very common in symptom-free patients with classic migraine, a CBF decrease being often accompanied by a CBV increase. In these patients both CT and MRI have a lower diagnostic yield than SPECT. (orig.).

  7. Autoradiography study and SPECT imaging of reporter gene HSV1-tk expression in heart

    Energy Technology Data Exchange (ETDEWEB)

    Lan Xiaoli [Department of Nuclear Medicine, Union Hospital, Tongji Medical College of Huazhong University of Science and Technology, Hubei Province Key Laboratory of Molecular Imaging, Wuhan, Hubei Province, 430022 (China)], E-mail: LXL730724@hotmail.com; Liu Ying; He Yong; Wu Tao; Zhang Binqing; Gao Zairong; An Rui [Department of Nuclear Medicine, Union Hospital, Tongji Medical College of Huazhong University of Science and Technology, Hubei Province Key Laboratory of Molecular Imaging, Wuhan, Hubei Province, 430022 (China); Zhang Yongxue [Department of Nuclear Medicine, Union Hospital, Tongji Medical College of Huazhong University of Science and Technology, Hubei Province Key Laboratory of Molecular Imaging, Wuhan, Hubei Province, 430022 (China)], E-mail: zhyx1229@163.com

    2010-04-15

    Aim: To demonstrate the feasibility and optimal conditions of imaging herpes simplex virus 1-thymidine kinase (HSV1-tk) gene transferred into hearts with {sup 131}I-2'-fluoro-2'-deoxy-1-{beta}-D-arabinofuranosyl-5-iodouracil ({sup 131}I-FIAU) using autoradiography (ARG) and single photon emission computed tomography (SPECT) in animal models. Methods: HSV1-tk inserted into adenovirus vector (Ad5-tk) and adenovirus (Ad5-null) was prepared. Rats or rabbits were divided into a study group receiving intramyocardial injection of Ad5-tk, and a control group receiving Ad-null injection. In the study group of rats, two sets of experiments, time-course study and dose-dependence study, were performed. In time-course experiments, rats were injected with {sup 131}I-FIAU on Days 1, 2, 3, 5 and 7, after transfection of 1x10{sup 8} pfu Ad5-tk, to study the feasibility and suitable time course for reporter gene imaging. In dose-dependence study, various titers of Ad5-tk (5x10{sup 8}, 1x10{sup 8}, 5x10{sup 7} and 1x10{sup 7} pfu) were used to determine the threshold and optimal viral titer needed for detection of gene expression. The gamma counts of hearts were measured. The rat myocardium was analyzed by ARG and reverse transcriptase-polymerase chain reaction (RT-PCR). SPECT whole-body planar imaging and cardiac tomographic imaging were performed in the rabbit models. Results: From the ARG images, rats injected with Ad5-tk showed significant {sup 131}I-FIAU activity in the anterolateral wall compared with background signals seen in the control Ad5-null rats. In time-course study, the highest radioactivity in the focal myocardium could be seen on Day 1, and then progressively declined with time. In dose-dependence study, the level of {sup 131}I-FIAU accumulation in the transfected myocardium declined with the decrease of Ad viral titers. From the ARG analysis and gamma counting, the threshold viral titer was 5x10{sup 7} pfu, and the optimal Ad titer was 1x10{sup 8} pfu

  8. Feasibility of a CdTe-based SPECT for high-resolution low-dose small animal imaging: a Monte Carlo simulation study

    International Nuclear Information System (INIS)

    Park, S-J; Yu, A R; Lee, Y-J; Kim, Y-S; Kim, H-J

    2014-01-01

    Dedicated single-photon-emission computed tomography (SPECT) systems based on pixelated semiconductors such as cadmium telluride (CdTe) are in development to study small animal models of human disease. In an effort to develop a high-resolution, low-dose system for small animal imaging, we compared a CdTe-based SPECT system and a conventional NaI(Tl)-based SPECT system in terms of spatial resolution, sensitivity, contrast, and contrast-to-noise ratio (CNR). In addition, we investigated the radiation absorbed dose and calculated a figure of merit (FOM) for both SPECT systems. Using the conventional NaI(Tl)-based SPECT system, we achieved a spatial resolution of 1.66 mm at a 30 mm source-to-collimator distance, and a resolution of 2.4-mm hot-rods. Using the newly-developed CdTe-based SPECT system, we achieved a spatial resolution of 1.32 mm FWHM at a 30 mm source-to-collimator distance, and a resolution of 1.7-mm hot-rods. The sensitivities at a 30 mm source-to-collimator distance were 115.73 counts/sec/MBq and 83.38 counts/sec/MBq for the CdTe-based SPECT and conventional NaI(Tl)-based SPECT systems, respectively. To compare quantitative measurements in the mouse brain, we calculated the CNR for images from both systems. The CNR from the CdTe-based SPECT system was 4.41, while that from the conventional NaI(Tl)-based SPECT system was 3.11 when the injected striatal dose was 160 Bq/voxel. The CNR increased as a function of injected dose in both systems. The FOM of the CdTe-based SPECT system was superior to that of the conventional NaI(Tl)-based SPECT system, and the highest FOM was achieved with the CdTe-based SPECT at a dose of 40 Bq/voxel injected into the striatum. Thus, a CdTe-based SPECT system showed significant improvement in performance compared with a conventional system in terms of spatial resolution, sensitivity, and CNR, while reducing the radiation dose to the small animal subject. Herein, we discuss the feasibility of a CdTe-based SPECT system for high

  9. Study on the usefulness of whole body SPECT coronal image, MIP image in 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Kawamura, Seiji

    2002-01-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with 67 Ga-citrate ( 67 Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  10. Preoperative diagnosis of orbital cavernous hemangioma: a 99mTc-RBC SPECT study.

    Science.gov (United States)

    Burroni, Luca; Borsari, Giulia; Pichierri, Patrizia; Polito, Ennio; Toscano, Olga; Grassetto, Gaia; Al-Nahhas, Adil; Rubello, Domenico; Vattimo, Angelo Giuseppe

    2012-11-01

    This study aimed to describe 99mTc-labeled RBC scintigraphy as a diagnostic method for orbital cavernous hemangiomas and to evaluate this diagnostic tool according to surgical outcomes. Fifty-five patients with clinical and radiological (US, CT, and/or MRI) suspicion of unilateral cavernous hemangioma of the orbit underwent 99mTc-RBC SPECT study.Qualitative and semiquantitative evaluations were performed, and results were statistically analyzed. SPECT images showed focal uptake in the orbital mass in 36 of 55 patients. Nineteen patients had a negative scintigraphic pattern, with concordance of early and late absence of uptake of 99mTc-RBC.Our procedure showed 100% sensitivity and 88.9% specificity for the diagnosis of orbital cavernous hemangioma, with a positive predictive value of 90.9% and a negative predictive value of 100%. 99mTc-RBC imaging is safe, easy to perform, and highly accurate in providing adequate clinical and surgical management. As a noninvasive and highly specific method for diagnosing orbital hemangioma, 99mTc-RBC scintigraphy can avoid more invasive imaging or biopsy.

  11. Technical issues relating to the statistical parametric mapping of brain SPECT studies

    International Nuclear Information System (INIS)

    Hatton, R.L.; Cordato, N.; Hutton, B.F.; Lau, Y.H.; Evans, S.G.

    2000-01-01

    Full text: Statistical Parametric Mapping (SPM) is a software tool designed for the statistical analysis of functional neuro images, specifically Positron Emission Tomography and functional Magnetic Resonance Imaging, and more recently SPECT. This review examines some problems associated with the analysis of SPECT. A comparison of a patient group with normal studies revealed factors that could influence results, some that commonly occur, others that require further exploration. To optimise the differences between two groups of subjects, both spatial variability and differences in global activity must be minimised. The choice and effectiveness of co registration method and approach to normalisation of activity concentration can affect the optimisation. A small number of subject scans were identified as possessing truncated data resulting in edge effects that could adversely influence the analysis. Other problems included unusual areas of significance possibly related to reconstruction methods and the geometry associated with nonparallel collimators. Areas of extra cerebral significance are a point of concern - and may result from scatter effects, or mis registration. Difficulties in patient positioning, due to postural limitations, can lead to resolution differences. SPM has been used to assess areas of statistical significance arising from these technical factors, as opposed to areas of true clinical significance when comparing subject groups. This contributes to a better understanding of the effects of technical factors so that these may be eliminated, minimised, or incorporated in the study design. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  12. Stem Cells for Cartilage Repair: Preclinical Studies and Insights in Translational Animal Models and Outcome Measures

    Directory of Open Access Journals (Sweden)

    Melissa Lo Monaco

    2018-01-01

    Full Text Available Due to the restricted intrinsic capacity of resident chondrocytes to regenerate the lost cartilage postinjury, stem cell-based therapies have been proposed as a novel therapeutic approach for cartilage repair. Moreover, stem cell-based therapies using mesenchymal stem cells (MSCs or induced pluripotent stem cells (iPSCs have been used successfully in preclinical and clinical settings. Despite these promising reports, the exact mechanisms underlying stem cell-mediated cartilage repair remain uncertain. Stem cells can contribute to cartilage repair via chondrogenic differentiation, via immunomodulation, or by the production of paracrine factors and extracellular vesicles. But before novel cell-based therapies for cartilage repair can be introduced into the clinic, rigorous testing in preclinical animal models is required. Preclinical models used in regenerative cartilage studies include murine, lapine, caprine, ovine, porcine, canine, and equine models, each associated with its specific advantages and limitations. This review presents a summary of recent in vitro data and from in vivo preclinical studies justifying the use of MSCs and iPSCs in cartilage tissue engineering. Moreover, the advantages and disadvantages of utilizing small and large animals will be discussed, while also describing suitable outcome measures for evaluating cartilage repair.

  13. Stem Cells for Cartilage Repair: Preclinical Studies and Insights in Translational Animal Models and Outcome Measures.

    Science.gov (United States)

    Lo Monaco, Melissa; Merckx, Greet; Ratajczak, Jessica; Gervois, Pascal; Hilkens, Petra; Clegg, Peter; Bronckaers, Annelies; Vandeweerd, Jean-Michel; Lambrichts, Ivo

    2018-01-01

    Due to the restricted intrinsic capacity of resident chondrocytes to regenerate the lost cartilage postinjury, stem cell-based therapies have been proposed as a novel therapeutic approach for cartilage repair. Moreover, stem cell-based therapies using mesenchymal stem cells (MSCs) or induced pluripotent stem cells (iPSCs) have been used successfully in preclinical and clinical settings. Despite these promising reports, the exact mechanisms underlying stem cell-mediated cartilage repair remain uncertain. Stem cells can contribute to cartilage repair via chondrogenic differentiation, via immunomodulation, or by the production of paracrine factors and extracellular vesicles. But before novel cell-based therapies for cartilage repair can be introduced into the clinic, rigorous testing in preclinical animal models is required. Preclinical models used in regenerative cartilage studies include murine, lapine, caprine, ovine, porcine, canine, and equine models, each associated with its specific advantages and limitations. This review presents a summary of recent in vitro data and from in vivo preclinical studies justifying the use of MSCs and iPSCs in cartilage tissue engineering. Moreover, the advantages and disadvantages of utilizing small and large animals will be discussed, while also describing suitable outcome measures for evaluating cartilage repair.

  14. Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study.

    Directory of Open Access Journals (Sweden)

    Oliver S Grosser

    Full Text Available Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT or positron emission tomography (PET with computed tomography (CT. Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR on the image quality of the low-dose CT images.Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88 and the contrast-to-noise ratio (CNR was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04. In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001.In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality.

  15. 123I-IMP SPECT studies in schizophrenia and atypical psychosis

    International Nuclear Information System (INIS)

    Hayashi, Takuji; Suga, Hidemichi

    1993-01-01

    According to the classification of Mitsuda, 23 patients with endogenous psychosis aged 40 years or younger, presenting with hallucination and delusion, were classified as having schizophrenia (n=12) or atypical psychosis (n=11). These patients were studied by single photon emission computed tomography (SPECT) with N-isopropyl-p-I-123-iodoamphetamine (I-123 IMP). Sixteen healthy persons served as controls. Early and delayed SPECT images were obtained 30 min and 4 hr, respectively, after intravenous injection of I-123 IMP. The group of schizophrenic patients had markedly decreased uptake of I-123 in the basal ganglia, as well as the right temporal and left occipital areas on both early and delayed images. In the group of atypical psychosis patients, however, decreased uptake of I-123 was noted in both the right basal ganglia and left occipital area on early images, but none of such findings were seen on delayed images. Regarding the uptake ratio in the frontal area on both early and delayed images, there were significant differences between the two groups. These findings have important implications for the different etiology of both disease types: not only functional disturbance in the frontal area but also irreversible changes may be involved in the occurrence of schizophrenia, and functional disturbance particularly in the right basal ganglia may be involved in the occurrence of atypical psychosis. (N.K.)

  16. 123I-β-CIT SPECT imaging study in early Parkinson's disease

    International Nuclear Information System (INIS)

    Li Peiyong

    1998-01-01

    Purpose: To investigate the loss of dopamine transporters in hemi-Parkinson's disease (PD) using 123 I-β-CIT/SPECT. Methods: Seven patients with hemi-Parkinson's disease and 7 age- and sex- matched healthy subjects were studied by 123 I-β-CIT/SPECT. Striatal specific uptake of 123 I-β-CIT was calculated in the ratio of striatal uptake to cerebellar uptake. Results: Mean striatal specific uptake of 123 I-β-CIT in healthy subjects was 3.0 +- 0.5 and 5.5 +- 0.6 at 3h and 18h after injection. Striatal specific uptake in contralateral to the clinical symptom side was 2.0 +- 0.8 and 3.1 +- 0.4; in ipsilateral striatum was 2.3 +- 0.4 and 4.0 +- 0.5. There was a significant reduction of striatal tracer uptake in PD patients compared to the controls. Patient age correlated with the reduction in contralateral striatum but did not correlate with that in ipsilateral striatum. Conclusions: Striatal dopamine transporters bilaterally lost in early PD patients. 123 I-β-CIT uptake in contralateral striatum was reduced more severely than in ipsilateral striatum

  17. [sup 123]I-IMP SPECT studies in schizophrenia and atypical psychosis

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Takuji; Suga, Hidemichi (Aichi Medical University, Nagakute (Japan))

    1993-05-01

    According to the classification of Mitsuda, 23 patients with endogenous psychosis aged 40 years or younger, presenting with hallucination and delusion, were classified as having schizophrenia (n=12) or atypical psychosis (n=11). These patients were studied by single photon emission computed tomography (SPECT) with N-isopropyl-p-I-123-iodoamphetamine (I-123 IMP). Sixteen healthy persons served as controls. Early and delayed SPECT images were obtained 30 min and 4 hr, respectively, after intravenous injection of I-123 IMP. The group of schizophrenic patients had markedly decreased uptake of I-123 in the basal ganglia, as well as the right temporal and left occipital areas on both early and delayed images. In the group of atypical psychosis patients, however, decreased uptake of I-123 was noted in both the right basal ganglia and left occipital area on early images, but none of such findings were seen on delayed images. Regarding the uptake ratio in the frontal area on both early and delayed images, there were significant differences between the two groups. These findings have important implications for the different etiology of both disease types: not only functional disturbance in the frontal area but also irreversible changes may be involved in the occurrence of schizophrenia, and functional disturbance particularly in the right basal ganglia may be involved in the occurrence of atypical psychosis. (N.K.).

  18. Dopamine transporter imaging with [{sup 123}I]FP-CIT SPECT: potential effects of drugs

    Energy Technology Data Exchange (ETDEWEB)

    Booij, Jan [University of Amsterdam, Department of Nuclear Medicine, Academic Medical Center, Amsterdam (Netherlands); Kemp, Paul [Southampton University Hospitals Trust, Department of Nuclear Medicine, Southampton (United Kingdom)

    2008-02-15

    [{sup 123}I]N-{omega}-fluoropropyl-2{beta}-carbomethoxy-3{beta}-{l_brace}4-iodophenyl{r_brace}nortropane ([{sup 123}I]FP-CIT) single photon emission computed tomography (SPECT) is a frequently and routinely used technique to detect or exclude dopaminergic degeneration by imaging the dopamine transporter (DAT) in parkinsonian and demented patients. This technique is also used in scientific studies in humans, as well as in preclinical studies to assess the availability of DAT binding in the striatum. In routine clinical studies, but also in scientific studies, patients are frequently on medication and sometimes even use drugs of abuse. Moreover, in preclinical studies, animals will be anesthetized. Prescribed drugs, drugs of abuse, and anesthetics may influence the visual interpretation and/or quantification of [{sup 123}I]FP-CIT SPECT scans. Here, we discuss the basic principle of how drugs and anesthetics might influence the visual interpretation and/or quantification of [{sup 123}I]FP-CIT SPECT scans. We also review drugs which are likely to have a significant influence on the visual interpretation and/or quantification of [{sup 123}I]FP-CIT SPECT scans. Additionally, we discuss the evidence as to whether frequently prescribed drugs in parkinsonian and demented patients may have an influence on the visual interpretation and/or quantification of [{sup 123}I]FP-CIT SPECT scans. Finally, we discuss our recommendations as to which drugs should be ideally withdrawn before performing a [{sup 123}I]FP-CIT SPECT scan for routine clinical purposes. The decision to withdraw any medication must always be made by the specialist in charge of the patient's care and taking into account the pros and cons of doing so. (orig.)

  19. Dopamine transporter imaging with [123I]FP-CIT SPECT: potential effects of drugs

    International Nuclear Information System (INIS)

    Booij, Jan; Kemp, Paul

    2008-01-01

    [ 123 I]N-ω-fluoropropyl-2β-carbomethoxy-3β-{4-iodophenyl}nortropane ([ 123 I]FP-CIT) single photon emission computed tomography (SPECT) is a frequently and routinely used technique to detect or exclude dopaminergic degeneration by imaging the dopamine transporter (DAT) in parkinsonian and demented patients. This technique is also used in scientific studies in humans, as well as in preclinical studies to assess the availability of DAT binding in the striatum. In routine clinical studies, but also in scientific studies, patients are frequently on medication and sometimes even use drugs of abuse. Moreover, in preclinical studies, animals will be anesthetized. Prescribed drugs, drugs of abuse, and anesthetics may influence the visual interpretation and/or quantification of [ 123 I]FP-CIT SPECT scans. Here, we discuss the basic principle of how drugs and anesthetics might influence the visual interpretation and/or quantification of [ 123 I]FP-CIT SPECT scans. We also review drugs which are likely to have a significant influence on the visual interpretation and/or quantification of [ 123 I]FP-CIT SPECT scans. Additionally, we discuss the evidence as to whether frequently prescribed drugs in parkinsonian and demented patients may have an influence on the visual interpretation and/or quantification of [ 123 I]FP-CIT SPECT scans. Finally, we discuss our recommendations as to which drugs should be ideally withdrawn before performing a [ 123 I]FP-CIT SPECT scan for routine clinical purposes. The decision to withdraw any medication must always be made by the specialist in charge of the patient's care and taking into account the pros and cons of doing so. (orig.)

  20. The development of neural stimulators: a review of preclinical safety and efficacy studies.

    Science.gov (United States)

    Shepherd, Robert K; Villalobos, Joel; Burns, Owen; Nayagam, David

    2018-05-14

    Given the rapid expansion of the field of neural stimulation and the rigorous regulatory approval requirements required before these devices can be applied clinically, it is important that there is clarity around conducting preclinical safety and efficacy studies required for the development of this technology. The present review examines basic design principles associated with the development of a safe neural stimulator and describes the suite of preclinical safety studies that need to be considered when taking a device to clinical trial. Neural stimulators are active implantable devices that provide therapeutic intervention, sensory feedback or improved motor control via electrical stimulation of neural or neuro-muscular tissue in response to trauma or disease. Because of their complexity, regulatory bodies classify these devices in the highest risk category (Class III), and they are therefore required to go through a rigorous regulatory approval process before progressing to market. The successful development of these devices is achieved through close collaboration across disciplines including engineers, scientists and a surgical/clinical team, and the adherence to clear design principles. Preclinical studies form one of several key components in the development pathway from concept to product release of neural stimulators. Importantly, these studies provide iterative feedback in order to optimise the final design of the device. Key components of any preclinical evaluation include: in vitro studies that are focussed on device reliability and include accelerated testing under highly controlled environments; in vivo studies using animal models of the disease or injury in order to assess safety and, given an appropriate animal model, the efficacy of the technology under both passive and electrically active conditions; and human cadaver and ex vivo studies designed to ensure the device's form factor conforms to human anatomy, to optimise the surgical approach and to

  1. Radiosynthesis, evaluation and preclinical studies of a new 5HT2A radioligand

    International Nuclear Information System (INIS)

    Mertens, J.; Terriere, D.; Baeken, C.; D'Haenan, H.; Flamen, P.; Bossuyt, A.; Leysen, J.

    1998-01-01

    123 I-5-I-R91150, a radioiodinated analogue of R91150 (a ligand (antagonist) of Janssen Research Foundation), showing high affinity and selectivity for 5HT 2A receptors, was developed as a potential in vivo 5HT 2A receptor tracer for SPECT. The applied radiochemistry, whereby the radioiodine was substituted on the 5 - position of the benzamide ring, allowed to obtain the tracer with high specific activity and high purity. In vitro and in vivo rat studies revealed that the new tracer bound reversibly with the required high affinity (Kd=0.1 nM) and high selectivity (a factor ranging from 10000 to at least 50 vis a vis other receptors) to 5HT 2A receptors. In young normal subjects the major part of the 123 I-5-I-R91150 radioactivity in the brain is present in cortical areas. Cortical area to cerebellum activity ratio reaches an equilibrium value of about 1.8 around 90 min. till 4 hours p.i.. This binding was specific and reversible. The cortical activity reflects a distribution in the brain similar to that of the mapping of 5HT 2A receptors from post mortem studies. These findings suggested that 123 I-5-I-R91150 allows imaging and quantitative estimation with SPECT and could be used for further clinical studies. The radiobromine analogue was synthetised as a potential PET tracer. (author)

  2. Effect of bypass on the motor activation SPECT compared to the acetazolamide SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Shoichiro; Iwahashi, Hideaki; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    2002-03-01

    The authors evaluated and analyzed motor activation single photon emission computed tomography (M-SPECT) in ischemic cerebrovascular disease compared to resting and acetazolamide (ACZ) activated SPECT studies. Seventeen cases with STA-MCA bypass performed for ischemic cerebrovascular disease were examined. The SPECT studies consisting of resting, ACZ activation, and motor activation stages were performed before bypass, at 1 month, and 3 months after bypass. The result of the M-SPECT was expressed as negative or positive. Before bypass: In all 17 cases, SPECT studies of the affected side showed reduction of resting cerebral blood flow (CBF) and reduction of cerebrovascular reserve capacity (CVRC). Eight cases were positive in the M-SPECT study. One week after bypass: The resting CBF increased in seven cases. Four showed preoperative positive M-SPECT. Eight cases showed improvement of the CVRC. Twelve cases were positive in M-SPECT, and two were negative in the preoperative M-SPECT. Three months after bypass: Thirteen cases showed improvement in the resting CBF, and fourteen cases showed improvement of the CVRC. Fourteen cases were positive in the M-SPECT, and among these, 6 were negative in the preoperative M-SPECT. There was a discrepancy between the improvement in CVRC and M-SPECT. M-SPECT study can provide information about the degree of hemodynamic compromise and effect of bypass surgery. (author)

  3. Effect of bypass on the motor activation SPECT compared to the acetazolamide SPECT

    International Nuclear Information System (INIS)

    Kawaguchi, Shoichiro; Iwahashi, Hideaki; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    2002-01-01

    The authors evaluated and analyzed motor activation single photon emission computed tomography (M-SPECT) in ischemic cerebrovascular disease compared to resting and acetazolamide (ACZ) activated SPECT studies. Seventeen cases with STA-MCA bypass performed for ischemic cerebrovascular disease were examined. The SPECT studies consisting of resting, ACZ activation, and motor activation stages were performed before bypass, at 1 month, and 3 months after bypass. The result of the M-SPECT was expressed as negative or positive. Before bypass: In all 17 cases, SPECT studies of the affected side showed reduction of resting cerebral blood flow (CBF) and reduction of cerebrovascular reserve capacity (CVRC). Eight cases were positive in the M-SPECT study. One week after bypass: The resting CBF increased in seven cases. Four showed preoperative positive M-SPECT. Eight cases showed improvement of the CVRC. Twelve cases were positive in M-SPECT, and two were negative in the preoperative M-SPECT. Three months after bypass: Thirteen cases showed improvement in the resting CBF, and fourteen cases showed improvement of the CVRC. Fourteen cases were positive in the M-SPECT, and among these, 6 were negative in the preoperative M-SPECT. There was a discrepancy between the improvement in CVRC and M-SPECT. M-SPECT study can provide information about the degree of hemodynamic compromise and effect of bypass surgery. (author)

  4. Delayed reflow of an ischemic infarct after spontaneous thrombolysis studied by CBF tomography using SPECT and Tc-99m HMPAO

    DEFF Research Database (Denmark)

    Companioni, J M; Lassen, N A; Tfelt-Hansen, P

    1991-01-01

    A patient with a large ischemic infarct in the left middle cerebral artery territory was studied six times in the acute/subacute phase by cerebral blood flow (CBF) tomography using Tc-99m-HMPAO. The SPECT instrument used was a brain dedicated highly sensitive four-camera system (TOMOMATIC 232...

  5. Establishment study of the in vivo imaging analysis with small animal imaging modalities (micro-PET and micro-SPECT/CT) for bio-drug development

    International Nuclear Information System (INIS)

    Jang, Beomsu; Park, Sanghyeon; Park, Jeonghoon; Jo, Sungkee; Jung, Uhee; Kim, Seolwha; Lee, Yunjong; Choi, Daeseong

    2011-01-01

    In this study, we established the image acquisition and analysis procedures of micro-PET, SPECT/CT using the experimental animal (mouse) for the development of imaging assessment method for the bio-drug. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with 99m Tc-MDP, DMSA, and 18 F-FDG. SPECT imaging studies using 3 types of pinhole collimators. 5-MWB collimator was used for SPECT image study. To study whole-body distribution, 99m Tc-MDP SPECT image study was performed. We obtained the fine distribution image. And the CT images was obtained to provide the anatomical information. And then these two types images are fused. To study specific organ uptake, we examined 99 mTc-DMSA SPECT/CT imaging study. We also performed the PET image study using U87MG tumor bearing mice and 18 F-FDG. The overnight fasting, warming and anesthesia with 2% isoflurane pretreatment enhance the tumor image through reducing the background uptake including brown fat, harderian gland and skeletal muscles. Also we got the governmental approval for use of x-ray generator for CT and radioisotopes as sealed and open source. We prepared the draft of process procedure for the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug

  6. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    Energy Technology Data Exchange (ETDEWEB)

    Golestani, Reza; Dierckx, Rudi A.J.O. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Wu, Chao [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Tio, Rene A. [University Medical Center Groningen, Thorax Center, Department of Cardiology, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Zeebregts, Clark J. [University Medical Center Groningen, Department of Surgery, Division of Vascular Surgery, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Petrov, Artiom D. [University of California, Irvine, Division of Cardiology, School of Medicine, Irvine, California (United States); Beekman, Freek J. [University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Section Radiation Detection and Medical Imaging, Delft (Netherlands); MILabs, Utrecht (Netherlands); Boersma, Hendrikus H. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Department of Clinical and Hospital Pharmacy, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Slart, Riemer H.J.A. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands)

    2010-09-15

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  7. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    International Nuclear Information System (INIS)

    Golestani, Reza; Dierckx, Rudi A.J.O.; Wu, Chao; Tio, Rene A.; Zeebregts, Clark J.; Petrov, Artiom D.; Beekman, Freek J.; Boersma, Hendrikus H.; Slart, Riemer H.J.A.

    2010-01-01

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  8. Quantitative study of 99mTc-Technegas SPECT for ventilatory impairment in pulmonary emphysema. Regional distribution. Correlation of SPECT with pulmonary function test

    International Nuclear Information System (INIS)

    Satoh, Katashi; Mitani, Masahiro; Yamamoto, Yuka; Nishiyama, Yoshihiro; Ohkawa, Motoomi

    2003-01-01

    99m Tc-Technegas scintigraphy is used for evaluation of abnormality of ventilation in pulmonary emphysema. Although the abnormality of ventilation distribution is very easy to find, there is not an objective index. The evaluation is subjective and different by each radiologist. It was also difficult to compare each cases and the clinical course in the same case. The present study for quantitative evaluation has proved that excellent correlations is obtained between the mean voxel values of the lung and stage classification. Furthermore, a correlation is observed between the mean and forced expiratory volume in 1 second (FEV 1.0 )%. These data indicate that quantitative analysis of SPECT seem to be useful to classify the clinical stage and compare the each cases. And respiratory function decreases as much as chronic pulmonary emphysema exists in the lower lung field. (author)

  9. Comparison between CT perfusion and Tc-99m ECD SPECT in the assessment of cerebrovascular reserve: a case study

    International Nuclear Information System (INIS)

    Crouch, J.; Wood, C.; Campbell, A.; McCarthy, M.; Dunne, M.; Bynevelt, M.; Lenzo, N.

    2003-01-01

    Full text: Brain perfusion is sensitively assessed by cerebral SPECT imaging utilising perfusion agents such as Tc-99m HMPAO and Tc-99m ethyl cysteinate dimer (ECD). Positron emission tomography can accurately assess and quantify brain perfusion and MRI can also be used for perfusion assessment. Both MRI and PET however are currently limited by cost and availability. A new technique utilising CT with contrast has been developed to assess and quantitate cerebral perfusion. The technique utilises arterial input information and deconvolution analysis to develop quantifiable measures of perfusion and contrast transit. The technique has been validated for acute stroke assessment and is being assessed for other possible applications. We present a case study comparison of this technique with cerebral SPECT perfusion using Tc-99m ECD in the assessment of cerebrovasular reserve. In each case, the CT and SPECT studies were performed pre- and post-acetazolamide and the SPECT study was statistically compared with a normal database utilising an automated brain perfusion statistical analysis package (NeurostatT). We discuss the correlation found between techniques, their strengths, weaknesses and possible future roles. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  10. Spinal Cord Tolerance in the Age of Spinal Radiosurgery: Lessons From Preclinical Studies

    International Nuclear Information System (INIS)

    Medin, Paul M.; Boike, Thomas P.

    2011-01-01

    Clinical implementation of spinal radiosurgery has increased rapidly in recent years, but little is known regarding human spinal cord tolerance to single-fraction irradiation. In contrast, preclinical studies in single-fraction spinal cord tolerance have been ongoing since the 1970s. The influences of field length, dose rate, inhomogeneous dose distributions, and reirradiation have all been investigated. This review summarizes literature regarding single-fraction spinal cord tolerance in preclinical models with an emphasis on practical clinical significance. The outcomes of studies that incorporate uniform irradiation are surprisingly consistent among multiple small- and large-animal models. Extensive investigation of inhomogeneous dose distributions in the rat has demonstrated a significant dose-volume effect while preliminary results from one pig study are contradictory. Preclinical spinal cord dose-volume studies indicate that dose distribution is more critical than the volume irradiated suggesting that neither dose-volume histogram analysis nor absolute volume constraints are effective in predicting complications. Reirradiation data are sparse, but results from guinea pig, rat, and pig studies are consistent with the hypothesis that the spinal cord possesses a large capacity for repair. The mechanisms behind the phenomena observed in spinal cord studies are not readily explained and the ability of dose response models to predict outcomes is variable underscoring the need for further investigation. Animal studies provide insight into the phenomena and mechanisms of radiosensitivity but the true significance of animal studies can only be discovered through clinical trials.

  11. Improving treatment of neurodevelopmental disorders: recommendations based on preclinical studies

    NARCIS (Netherlands)

    Homberg, J.R.; Kyzar, E.J.; Stewart, A.M.; Nguyen, M; Poudel, M.K.; Echevarria, D.J.; Collier, A.D.; Gaikwad, S.; Klimenko, V.M.; Norton, W.; Pittman, J.; Nakamura, S.; Koshiba, M.; Yamanouchi, H.; Apryatin, S.A.; Scattoni, M.L.; Diamond, D.M.; Ullmann, J.F.; Parker, M.O.; Brown, R.E.; Song, C.; Kalueff, A.V.

    2016-01-01

    INTRODUCTION: Neurodevelopmental disorders (NDDs) are common and severely debilitating. Their chronic nature and reliance on both genetic and environmental factors makes studying NDDs and their treatment a challenging task. AREAS COVERED: Herein, the authors discuss the neurobiological mechanisms of

  12. Evaluation of image reconstruction methods for 123I-MIBG-SPECT. A rank-order study

    International Nuclear Information System (INIS)

    Soederberg, Marcus; Mattsson, Soeren; Oddstig, Jenny; Uusijaervi-Lizana, Helena; Leide-Svegborn, Sigrid; Valind, Sven; Thorsson, Ola; Garpered, Sabine; Prautzsch, Tilmann; Tischenko, Oleg

    2012-01-01

    Background: There is an opportunity to improve the image quality and lesion detectability in single photon emission computed tomography (SPECT) by choosing an appropriate reconstruction method and optimal parameters for the reconstruction. Purpose: To optimize the use of the Flash 3D reconstruction algorithm in terms of equivalent iteration (EI) number (number of subsets times the number of iterations) and to compare with two recently developed reconstruction algorithms ReSPECT and orthogonal polynomial expansion on disc (OPED) for application on 123 I-metaiodobenzylguanidine (MIBG)-SPECT. Material and Methods: Eleven adult patients underwent SPECT 4 h and 14 patients 24 h after injection of approximately 200 MBq 123 I-MIBG using a Siemens Symbia T6 SPECT/CT. Images were reconstructed from raw data using the Flash 3D algorithm at eight different EI numbers. The images were ranked by three experienced nuclear medicine physicians according to their overall impression of the image quality. The obtained optimal images were then compared in one further visual comparison with images reconstructed using the ReSPECT and OPED algorithms. Results: The optimal EI number for Flash 3D was determined to be 32 for acquisition 4 h and 24 h after injection. The average rank order (best first) for the different reconstructions for acquisition after 4 h was: Flash 3D 32 > ReSPECT > Flash 3D 64 > OPED, and after 24 h: Flash 3D 16 > ReSPECT > Flash 3D 32 > OPED. A fair level of inter-observer agreement concerning optimal EI number and reconstruction algorithm was obtained, which may be explained by the different individual preferences of what is appropriate image quality. Conclusion: Using Siemens Symbia T6 SPECT/CT and specified acquisition parameters, Flash 3D 32 (4 h) and Flash 3D 16 (24 h), followed by ReSPECT, were assessed to be the preferable reconstruction algorithms in visual assessment of 123 I-MIBG images

  13. Factors influencing the approaches to studying of preclinical and clinical students and postgraduate trainees

    Directory of Open Access Journals (Sweden)

    Samarasekera Dharmabandu N

    2011-05-01

    Full Text Available Abstract Background Students can be classified into three categories depending on their approaches to studying; namely, deep approach (DA, strategic approach (SA and surface apathetic or superficial approach (SAA. The aim of this study was to identify factors affecting the approaches to studying among Sri Lankan medical undergraduates and post graduate trainees and to analyze the change in the pattern of study skills with time and experience. Method Pre-clinical and clinical students of the Faculty of Medicine, University of Colombo and postgraduate trainees in Surgery at the National Hospital of Sri Lanka were invited to complete the Approaches and Study Skills Inventory for Students (ASSIST questionnaire. Results A total of 187 pre clinical (M: F = 96:91, 124 clinical (M: F = 61:63 and 53 post graduate trainees (M: F = 50:3 participated in the study. Approaches of male and female students were similar. SA was significantly affected by age among the preclinical students (p = 0.01, but not in other groups. Among pre-clinical students, males preferred a teacher who supported understanding (p = 0.04 but females preferred a passive transmission of information (p Conclusion Different factors affect the approach to studying in different groups but these explain only a small fraction of the variance observed.

  14. Preclinical Studies of a Kidney Safe Iodinated Contrast Agent.

    Science.gov (United States)

    Rowe, Elizabeth S; Rowe, Vernon D; Biswas, Sangita; Mosher, Gerold; Insisienmay, Lovella; Ozias, Marlies K; Gralinski, Michael R; Hunter, John; Barnett, James S

    2016-09-01

    Contrast-induced acute kidney injury (CI-AKI) is a serious complication of the use of iodinated contrast agents. This problem is particularly acute in interventional neurology and interventional cardiology, probably due to the intra-arterial route of injection, high contrast volumes, and preexisting risk factors of these patients. In an attempt to develop a contrast agent that is less damaging to the kidneys, we have studied the effects of adding a small amount of the substituted cyclodextrin, sulfobutyl-ether-β-cyclodextrin (SBECD), to iohexol in rodent models of renal toxicity. Renally compromised mice and rats were injected with iohexol and iohexol-SBECD via the tail vein. The renal pathology, creatinine clearance, and survival benefits of iohexol-SBECD were studied. The safety of direct intra-arterial injection of the iohexol-SBECD formulation was studied in a dog heart model system. Mechanism of action studies in cell culture model using a human kidney cell line was performed using flow cytometry. Nephrotoxicity was significantly reduced using iohexol-SBECD compared to iohexol alone, at mole ratios of iohexol:SBECD of 1:0.025. SBECD increased survival from 50% to 88% in a rat survival study. In the dog heart model, iohexol-SBECD was safe. Cell culture studies suggest that SBECD interferes with the early stages of contrast-induced apoptosis in a human renal cell line. We have shown that the addition of a small amount of SBECD (one molecule of SBECD per 40 iohexol molecules) significantly protects rodent kidneys from CI-AKI. Further development of this new formulation of iodinated contrast is warranted. © 2016 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  15. Reproducibility and replicability of rodent phenotyping in preclinical studies

    NARCIS (Netherlands)

    Kafkafi, Neri; Agassi, Joseph; Chesler, Elissa J.; Crabbe, John C.; Crusio, Wim E.; Eilam, David; Gerlai, Robert; Golani, Ilan; Gomez-Marin, Alex; Heller, Ruth; Iraqi, Fuad; Jaljuli, Iman; Karp, Natasha A.; Morgan, Hugh; Nicholson, George; Pfaff, Donald W.; Richter, S. Helene; Stark, Philip B.; Stiedl, Oliver; Stodden, Victoria; Tarantino, Lisa M.; Tucci, Valter; Valdar, William; Williams, Robert W.; Würbel, Hanno; Benjamini, Yoav

    The scientific community is increasingly concerned with the proportion of published “discoveries” that are not replicated in subsequent studies. The field of rodent behavioral phenotyping was one of the first to raise this concern, and to relate it to other methodological issues: the complex

  16. Evaluation of reconstruction techniques in regional cerebral blood flow SPECT using trade-off plots: a Monte Carlo study.

    Science.gov (United States)

    Olsson, Anna; Arlig, Asa; Carlsson, Gudrun Alm; Gustafsson, Agnetha

    2007-09-01

    The image quality of single photon emission computed tomography (SPECT) depends on the reconstruction algorithm used. The purpose of the present study was to evaluate parameters in ordered subset expectation maximization (OSEM) and to compare systematically with filtered back-projection (FBP) for reconstruction of regional cerebral blood flow (rCBF) SPECT, incorporating attenuation and scatter correction. The evaluation was based on the trade-off between contrast recovery and statistical noise using different sizes of subsets, number of iterations and filter parameters. Monte Carlo simulated SPECT studies of a digital human brain phantom were used. The contrast recovery was calculated as measured contrast divided by true contrast. Statistical noise in the reconstructed images was calculated as the coefficient of variation in pixel values. A constant contrast level was reached above 195 equivalent maximum likelihood expectation maximization iterations. The choice of subset size was not crucial as long as there were > or = 2 projections per subset. The OSEM reconstruction was found to give 5-14% higher contrast recovery than FBP for all clinically relevant noise levels in rCBF SPECT. The Butterworth filter, power 6, achieved the highest stable contrast recovery level at all clinically relevant noise levels. The cut-off frequency should be chosen according to the noise level accepted in the image. Trade-off plots are shown to be a practical way of deciding the number of iterations and subset size for the OSEM reconstruction and can be used for other examination types in nuclear medicine.

  17. Intradermal Inactivated Poliovirus Vaccine: A Preclinical Dose-Finding Study

    OpenAIRE

    Kouiavskaia, Diana; Mirochnitchenko, Olga; Dragunsky, Eugenia; Kochba, Efrat; Levin, Yotam; Troy, Stephanie; Chumakov, Konstantin

    2014-01-01

    Intradermal delivery of vaccines has been shown to result in dose sparing. We tested the ability of fractional doses of inactivated poliovirus vaccine (IPV) delivered intradermally to induce levels of serum poliovirus-neutralizing antibodies similar to immunization through the intramuscular route. Immunogenicity of fractional doses of IPV was studied by comparing intramuscular and intradermal immunization of Wistar rats using NanoPass MicronJet600 microneedles. Intradermal delivery of partial...

  18. Quantitative evaluation in tumor SPECT and the effect of tumor size. Fundamental study with phantom

    International Nuclear Information System (INIS)

    Togawa, Takashi; Yui, Nobuharu; Kinoshita, Fujimi; Yanagisawa, Masamichi

    1997-01-01

    An experimental study with phantoms was performed in order to evaluate the effect of the tumor volume on the quantitative estimation in tumor SPECT. The ratio of mean count/pixel in the phantom to that of the background (T/N ratio) was well correlated with the size of the phantom; even when the concentration of the Tc-99m O 4 - solution of globular phantoms with diameters of 29, 37 and 46 mm was constant, the greater the size of the phantom, the higher was the T/N ratio. This study showed that we should understand that the T/N ratio was certainly affected by the reduction of the tumor size itself whenever we evaluate treatment response or assess tumor viability after treatment by reference to the T/N ratio. (author)

  19. Prevalence of incidental or unexpected findings on low-dose CT performed during routine SPECT/CT nuclear medicine studies

    International Nuclear Information System (INIS)

    Yap, Kelvin Kwok-Ho; Sutherland, Tom; Shafik-Eid, Raymond; Taubman, Kim; Schlicht, Stephen; Ramaseshan, Ganeshan

    2015-01-01

    In nuclear medicine, single-photon-emission computed tomography (SPECT) is often combined with ‘simultaneous’ low-dose CT (LDCT) to provide complementary anatomical and functional correlation. As a consequence, numerous incidental and unexpected findings may be detected on LDCT. Recognition of these findings and appropriate determination of their relevance can add to the utility of SPECT/CT. We aimed to evaluate the prevalence and categorise the relevance of incidental and unexpected findings on LDCT scans performed as part of routine SPECT/CT studies. All available LDCT scans performed as part of SPECT/CT studies at St. Vincent's Hospital Melbourne in the year 2013 were retrospectively reviewed. Two qualified radiologists independently reviewed the studies and any previous available imaging and categorised any detected incidental findings. A total of 2447 LDCT studies were reviewed. The relevance of the findings was classified according to a modified version of a scale used in the Colonography Reporting and Data System: E1 = normal or normal variant (28.0%); E2 = clinically unimportant (63.5%); E3 = likely unimportant or incompletely characterised (6.2%); E4 = potentially important (2.5%). Imaging specialists need to be cognisant of incidental and unexpected findings present on LDCT studies performed as part of SPECT/CT. Appropriate categorisation of findings and communication of potentially important findings to referring clinicians should form part of routine practice. The overall prevalence of potentially significant incidental and unexpected findings in our series was 8.7% (E3, 6.2%; E4, 2.5%) and was comparable to rates in other published imaging series.

  20. Laparoscopic kidney orthotopic transplant: preclinical study in the pig model.

    Science.gov (United States)

    He, B; Musk, G C; Mou, L; Waneck, G L; Delriviere, L

    2013-06-01

    Laparoscopic surgery has rapidly expanded in clinical practice replacing conventional open surgery over the last three decades. Laparoscopic donor nephrectomy has been favored due to its multiple benefits. The aim of this study was to explore the safety and feasibility of kidney transplantation by a laparoscopic technique in a pig model. The study was approved by the university animal ethics committee. Eight female pigs (Sus Scrofra, weighing 45-50 kg) were divided into 2 groups: group I included 4 animals that underwent laparoscopic kidney orthotopic transplantation on the left side. The right kidney was remained functional in situ. The pigs recovered and were observed for 1 week. In the 4 hosts group II pigs underwent a laparoscopic kidney transplantation on the left side. With simultaneous clipping of the right ureter. After recovery, the pigs were observed for 4 weeks. A laparotomy for examination was performed prior to euthanasia. All 4 group I pigs survived for 1 week. The laparotomy showed normal graft perfusion with wall patent renal artery and vein as well as satisfactory urine output upon transection of ureter in 3 hosts. Renal artery stenosis occurred in one pig. In The Immediate kidney graft function was achieved in 3 group II pigs. The fourth died following extubation due to laryngospasm despite a functional graft. The average creatinine levels were 195.5 μmol/L on day 3; 224.5 μmol/L at week 1; 127 μmol/L at week 2; 182.7 umol/L at week 3; and 154.7 umol/L at week 4. Laparoscopic kidney transplantation was feasible and safe in a pig model with immediate graft function. This study will provide further evidence to support application of laparoscopic technique to human kidney transplant. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. SPECT in psychiatry

    International Nuclear Information System (INIS)

    Kasper, S.; Gruenwald, F.; Walter, H.; Klemm, E.; Podreka, I.; Biersack, H.J.

    1994-01-01

    In the last fifteen years different attempts have been undertaken to understand the biological basis of major psychiatric disorders. One important tool to determine patterns of brain dysfunction is single emission computed tomography (SPECT). Whereas SPECT investigations are already a valuable diagnostic instrument for the diagnosis of dementia of the Alzheimer Type (DAT) there have not been consistent findings that can be referred to as specific for any other particular psychiatric diagnostic entity. Nevertheless, SPECT studies have been able to demonstrate evidence of brain dysfunction in patients with schizophrenia, depression, anxiety disorders, and substance abuse in which other methods showed no clear abnormality of brain function. Our manuscript reviews the data which are currently available in the literature and stresses the need for further studies, especially for prediction and monitoring psychiatric treatment modalities. (orig.) [de

  2. Association of taxanes and radiotherapy: preclinical and clinical studies

    International Nuclear Information System (INIS)

    Hennequin, C.

    2004-01-01

    Taxanes (paclitaxel and docetaxel) stabilized microtubules against depolymerization, and inhibit their function. Their radiosensitizing properties have been discovered more than 10 years ago; they synchronized tumor cells in G2/M phase, the most radiosensitive portion of the cell cycle. Other radiosensitizing mechanisms have been also discussed, as reoxygenation, promotion of radio-apoptosis and anti-angiogenic cooperation. Many phase I and II studies have been performed, essentially in bronchus and head and neck carcinomas. In lung cancer, paclitaxel was delivered weekly at a dose of 60 mg/m 2 . Many studies combined cisplatin or carbo-platin with paclitaxel, demonstrating that this combination is feasible and efficient. Only one phase III trial was reported; after two cycles of chemotherapy for inoperable lung cancers, radiotherapy was delivered, with or without paclitaxel radiosensitization: a benefit in disease-free survival was observed for the combination arm. In head and neck carcinomas, concomitant association of cisplatin, paclitaxel and radiation was feasible and showed promising results. Clinical trials with docetaxel are in progress. (author)

  3. Pre- and postsynaptic dopamine SPECT in the early phase of idiopathic parkinsonism: a population-based study

    Energy Technology Data Exchange (ETDEWEB)

    Jakobson, Mo Susanna; Riklund, Katrine [Umeaa University, Department of Radiation Sciences, Diagnostic Radiology, Umeaa (Sweden); Linder, Jan; Forsgren, Lars [Umeaa University, Department of Pharmacology and Clinical Neuroscience, Neurology, Umeaa (Sweden); Larsson, Anne; Johansson, Lennart [Umeaa University, Department of Radiation Sciences, Radiation Physics, Umeaa (Sweden)

    2010-11-15

    The aim of this study was to assess the diagnostic contribution of pre- and postsynaptic dopamine SPECT in drug-naive patients with early idiopathic parkinsonism and to investigate possible differences between idiopathic Parkinson's disease (PD) and atypical parkinsonian syndromes (APS) and possible differences in motor subtypes of parkinsonism. A group of 128 newly diagnosed idiopathic parkinsonian patients and 48 healthy controls was studied. Presynaptic baseline SPECT with {sup 123}I-FP-CIT was performed in all patients and in 120 patients also a baseline postsynaptic SPECT with {sup 123}I-IBZM. Clinical diagnoses were reassessed after 12 months. Presynaptic uptake in the putamen and caudate was significantly reduced in patients compared to controls. Presynaptic uptake ratios were not different between PD patients and patients with APS, and postsynaptic uptake in APS was not significantly reduced compared to PD or controls. In half of the APS patients both pre- and postsynaptic uptake ratios were reduced on the same side in the striatum. Impaired motor performance was associated with decreased presynaptic uptake in the putamen in PD. The postural instability and gait difficulty (PIGD) subtype of PD had lower presynaptic uptake ratios than patients with tremor-dominated (TD) symptoms. Not only presynaptic putamen uptake ratios, but also caudate ratios were reduced in a majority of the patients in our study. At baseline scan, i.e. in an early stage of the disease, the accuracy of excluding APS in the whole study population was 85% using a combination of pre- and postsynaptic SPECT. Already at baseline, lower presynaptic SPECT ratios were seen in PD with PIGD at onset compared to those with TD subtype. (orig.)

  4. Intradermal inactivated poliovirus vaccine: a preclinical dose-finding study.

    Science.gov (United States)

    Kouiavskaia, Diana; Mirochnitchenko, Olga; Dragunsky, Eugenia; Kochba, Efrat; Levin, Yotam; Troy, Stephanie; Chumakov, Konstantin

    2015-05-01

    Intradermal delivery of vaccines has been shown to result in dose sparing. We tested the ability of fractional doses of inactivated poliovirus vaccine (IPV) delivered intradermally to induce levels of serum poliovirus-neutralizing antibodies similar to immunization through the intramuscular route. Immunogenicity of fractional doses of IPV was studied by comparing intramuscular and intradermal immunization of Wistar rats using NanoPass MicronJet600 microneedles. Intradermal delivery of partial vaccine doses induced antibodies at titers comparable to those after immunization with full human dose delivered intramuscularly. The results suggest that intradermal delivery of IPV may lead to dose-sparing effect and reduction of the vaccination cost. Published by Oxford University Press on behalf of the Infectious Diseases Society of America 2014. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  5. Cocoa Diet and Antibody Immune Response in Preclinical Studies

    Directory of Open Access Journals (Sweden)

    Mariona Camps-Bossacoma

    2017-06-01

    Full Text Available The ability of cocoa to interact with the immune system in vitro and in vivo has been described. In the latter context, a cocoa-enriched diet in healthy rats was able to modify the immune system’s functionality. This fact could be observed in the composition and functionality of lymphoid tissues, such as the thymus, spleen, and lymph nodes. Consequently, immune effector mechanisms, such as antibody synthesis, were modified. A cocoa-enriched diet in young rats was able to attenuate the serum levels of immunoglobulin (Ig G, IgM, and IgA and also the intestinal IgM and IgA secretion. Moreover, in immunized rats, the intake of cocoa decreased specific IgG1, IgG2a, IgG2c, and IgM concentrations in serum. This immune-regulator potential was then tested in disease models in which antibodies play a pathogenic role. A cocoa-enriched diet was able to partially prevent the synthesis of autoantibodies in a model of autoimmune arthritis in rats and was also able to protect against IgE and T helper 2-related antibody synthesis in two rat models of allergy. Likewise, a cocoa-enriched diet prevented an oral sensitization process in young rats. In this review, we will focus on the influence of cocoa on the acquired branch of the immune function. Therefore, we will focus on how a cocoa diet influences lymphocyte function both in the systemic and intestinal immune system. Likewise, its potential role in preventing some antibody-induced immune diseases is also included. Although further studies must characterize the particular cocoa components responsible for such effects and nutritional studies in humans need to be carried out, cocoa has potential as a nutraceutical agent in some hypersensitivity status.

  6. A study of full width at half maximum (FWHM) according to the filter's cut off level in SPECT camera

    International Nuclear Information System (INIS)

    Park, Soung Ock; Kwon, Soo Il

    2003-01-01

    Filtering is necessary to reduce statistical noise and to increase image quality in SPECT images. Noises controlled by low-pass filter designed to suppress high spatial frequency in SPECT image. Most SPECT filter function control the degree of high frequency suppression by choosing a cut off frequency. The location of cut off frequency determines the affect image noise and spatial resolution. If select the low cut off frequency, its provide good noise suppression but insufficient image quantity and high cut off frequencies increase the image resolution but insufficient noise suppression. The purpose of this study was to determines the optimum cut off level with comparison of FWHM according to cut off level in each filters-Band-limited, Sheep-logan, Sheep-logan Hanning, Generalized Hamming, Low pass cosine, Parazen and Butterworth filter in SPECT camera. We recorded image along the X, Y, Z-axis with 99m TcO 4 point source and measured FWHM by use profile curve. We find averaged length is 9.16 mm ∼ 18.14 mm of FWHM in X, Y, and Z-axis, and Band-limited and Generalized Hamming filters measures 9.16 mm at 0.7 cycle/pixel cut off frequency

  7. Basic study for the purpose of developing a quantitative "6"7Ga-SPECT measurement method

    International Nuclear Information System (INIS)

    Nakanishi, Kensuke; Sakata, Reiki; Takaki, Akihiro; Ito, Shigeki; Nakasone, Yutaka; Kadota, Masataka

    2017-01-01

    "6"7Ga-single photon emission computed tomography (SPECT) images vary according to the imaging time and image display methods. The calculation of an index, such as the standardized uptake value used in positron emission tomography, from "6"7Ga-SPECT images would enable the accurate evaluation of the region of accumulation. The purpose of this study was to elucidate the conversion formula, the lower detection limit (LDL), and recovery coefficient (RC) for quantifying the radiation concentration in the "6"7Ga accumulation site. After chronologically obtaining SPECT/CT images at a radiation concentration of 1.0-442.4 kBq/mL with 27 bottles (diameter: 48 mm ,100 mL), the radiation concentration conversion formula was calculated using the successive approximation reconstruction method. The conversion coefficient was then calculated from the relationship between the count rate and the radiation concentration, and the LDL was determined. To compensate for the partial volume effect, the recovery curve was calculated using the mean SPECT count for six bottles (diameter: 9 ,18 , 29, 38, 48, and 94 mm). There was a linear relationship between the radiation concentration and the count rate with a good correlation (r=0.99). The LDL was 1.0 kBq/mL. The recovery curve reached a plateau at a diameter of at least 48 mm. The calculation of the absorbed dose index was possible using the radiation concentration conversion formula and the RC. (author)

  8. Curcumin-Artemisinin Coamorphous Solid: Xenograft Model Preclinical Study

    Directory of Open Access Journals (Sweden)

    M. K. Chaitanya Mannava

    2018-01-01

    Full Text Available Curcumin is a natural compound present in Indian spice turmeric. It has diverse pharmacological action but low oral solubility and bioavailability continue to limit its use as a drug. With the aim of improving the bioavailability of Curcumin (CUR, we evaluated Curcumin-Pyrogallol (CUR-PYR cocrystal and Curcumin-Artemisinin (CUR-ART coamorphous solid. Both of these solid forms exhibited superior dissolution and pharmacokinetic behavior compared to pure CUR, which is practically insoluble in water. CUR-ART coamorphous solid showed two fold higher bioavailability than CUR-PYR cocrystal (at 200 mg/kg oral dose. Moreover, in simulated gastric and intestinal fluids (SGF and SIF, CUR-ART is stable up to 3 and 12 h, respectively. In addition, CUR-PYR and CUR-ART showed no adverse effects in toxicology studies (10 times higher dose at 2000 mg/kg. CUR-ART showed higher therapeutic effect and inhibited approximately 62% of tumor growth at 100 mg/kg oral dosage of CUR in xenograft models, which is equal to the positive control drug, doxorubicin (2 mg/kg by i.v. administration.

  9. Reproducibility and replicability of rodent phenotyping in preclinical studies.

    Science.gov (United States)

    Kafkafi, Neri; Agassi, Joseph; Chesler, Elissa J; Crabbe, John C; Crusio, Wim E; Eilam, David; Gerlai, Robert; Golani, Ilan; Gomez-Marin, Alex; Heller, Ruth; Iraqi, Fuad; Jaljuli, Iman; Karp, Natasha A; Morgan, Hugh; Nicholson, George; Pfaff, Donald W; Richter, S Helene; Stark, Philip B; Stiedl, Oliver; Stodden, Victoria; Tarantino, Lisa M; Tucci, Valter; Valdar, William; Williams, Robert W; Würbel, Hanno; Benjamini, Yoav

    2018-04-01

    The scientific community is increasingly concerned with the proportion of published "discoveries" that are not replicated in subsequent studies. The field of rodent behavioral phenotyping was one of the first to raise this concern, and to relate it to other methodological issues: the complex interaction between genotype and environment; the definitions of behavioral constructs; and the use of laboratory mice and rats as model species for investigating human health and disease mechanisms. In January 2015, researchers from various disciplines gathered at Tel Aviv University to discuss these issues. The general consensus was that the issue is prevalent and of concern, and should be addressed at the statistical, methodological and policy levels, but is not so severe as to call into question the validity and the usefulness of model organisms as a whole. Well-organized community efforts, coupled with improved data and metadata sharing, have a key role in identifying specific problems and promoting effective solutions. Replicability is closely related to validity, may affect generalizability and translation of findings, and has important ethical implications. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. A study of preclinical myocardial damage in diabetes mellitus

    International Nuclear Information System (INIS)

    Mizuno, Sumio

    1986-01-01

    The scintigrams were evaluated by visual and circumferential profile analysis. In addition, mechanocardiography (MCG) and functional tests of the autonomic nerves were done. Coronary angiography and left ventriculography (LVG) were performed in 22 patients having cardiac symptoms. Of 61 patients, 20 (32, 8 %) showed perfusion defects in the scintigram (positive cases), consisting of 5 with stress-induced defect and 15 with fixed defect. The scintigrams in 41 patients showed normal perfusion of thallium (negative cases). The positive cases had more severe diabetic complications and longer duration of diabetes compared with the negative cases. The positive cases were incident to the treatment with insulin or oral drugs. Both systolic time intervals (STIs) in MCG and coefficients of variation of heart rate (CV) decreased in the diabetics, particularly in the positive cases. However, the decrement of STIs and CV was not significantly different in quantity between positive and negative cases; results therefore suggest that these two parameters may not correlate directly with the perfusion defects on Tl-201 scintigraphy. Twenty-two patients, 9 positive and 13 negative cases, had undergone cardiac catheterization, and showed normal coronary angiograms. On hemodynamic study, an ejection fraction decreased more in the positive cases than in the negative cases. The 13 negative cases showed normal wall motion in the LVG. Seven of the 9 positive cases, however, showed local hypokinetic wall motion. Abnormalities of the LVG corresponded to findings of the scintigram, i. e., perfusion defects or decrement of washout rate. On circumferential profile analysis, the mean washout rate of the whole heart decreased only in the positive cases. (J.P.N.)

  11. Learning style preferences: A study of pre-clinical medical students in Barbados

    OpenAIRE

    OJEH, NKEMCHO; SOBERS-GRANNUM, NATASHA; GAUR, UMA; UDUPA, ALAYA; MAJUMDER, MD.ANWARUL AZIM

    2017-01-01

    Introduction: Educators need to be aware of different learning styles to effectively tailor instructional strategies and methods to cater to the students’ learning needs and support a conductive learning environment. The VARK [an acronym for visual (V), aural (A), read/write (R) and kinesthetic (K)] instrument is a useful model to assess learning styles. The aim of this study was to use the VARK questionnaire to determine the learning styles of pre-clinical medical students in order to compar...

  12. The study of I-123-IMP-SPECT before and after surgery for craniosynostosis

    International Nuclear Information System (INIS)

    Satoh, Motohiro; Ishikawa, Nobuyoshi; Enomoto, Takao; Takeda, Tohru; Yoshizawa, Takashi; Nose, Tadao.

    1990-01-01

    Single photon emission computed tomography with N-isopropyl-p-[I-123]iodoamphetamine was performed in 13 cases of craniosynostosis before and after surgery. Of 13 cases, 8 cases (62%) showed focal low perfusion area on preoperative study. Four of seven cases (57%) with brachycephaly showed low perfusion areas in either of frontal lobes, occipital lobes, and cerebellum. Besides, two patients with scaphocephaly and one with plagiocephaly showed low perfusion area in the unilateral cerebral hemisphere. Two Crouzon disease cases showed no focal low perfusion area, but an Apert disease showed low perfusion areas in both frontal lobes, cerebellum, as well as left occipital lobe. Corresponding CT and MRI showed no focal abnormality in any of these cases. These low perfusion areas were diminished or disappeared after surgical treatment in 6 cases (75%). We conclude that the I-123-IMP-SPECT is considered to be a useful index for the evaluation of functional recovery after surgery in cases of craniosynostosis. (author)

  13. Normal anatomy of lung perfusion SPECT scintigraphy

    International Nuclear Information System (INIS)

    Moskowitz, G.W.; Levy, L.M.

    1987-01-01

    Ten patients studies for possible pulmonary embolic disease had normal lung perfusion planar and SPECT scintigraphy. A computer program was developed to superimpose the CT scans on corresponding SPECT images. Superimposition of CT scans on corresponding SPECT transaxial cross-sectional images, when available, provides the needed definition and relationships of adjacent organs. SPECT transaxial sections provide clear anatomic definition of perfusion defects without foreground and background lung tissue superimposed. The location, shape, and size of the perfusion defects can be readily assessed by SPECT. An algorithm was developed for the differentiation of abnormal pulmonary perfusion patterns from normal structures on variation

  14. Thymoquinone as a Potential Adjuvant Therapy for Cancer Treatment: Evidence from Preclinical Studies

    Directory of Open Access Journals (Sweden)

    A.G.M. Mostofa

    2017-06-01

    Full Text Available Thymoquinone (TQ, the main bioactive component of Nigella sativa, has been found to exhibit anticancer effects in numerous preclinical studies. Due to its multitargeting nature, TQ interferes in a wide range of tumorigenic processes and counteracts carcinogenesis, malignant growth, invasion, migration, and angiogenesis. Moreover, TQ can specifically sensitize tumor cells toward conventional cancer treatments (e.g., radiotherapy, chemotherapy, and immunotherapy and simultaneously minimize therapy-associated toxic effects in normal cells. In this review, we summarized the adjuvant potential of TQ as observed in various in vitro and in vivo animal models and discussed the pharmacological properties of TQ to rationalize its supplementary role in potentiating the efficacy of standard therapeutic modalities namely surgery, radiotherapy, chemotherapy, and immunotherapy. Altogether, we suggest further comprehensive evaluation of TQ in preclinical and clinical levels to delineate its implied utility as a novel complementary adjuvant therapy for cancer treatment.

  15. Exploratory study of factors related to educational scores of first preclinical year medical students.

    Science.gov (United States)

    Sitticharoon, Chantacha; Srisuma, Sorachai; Kanavitoon, Sawita; Summachiwakij, Sarayut

    2014-03-01

    The relationships among the scores of major subjects taught in the first preclinical year of a Thai medical school, previous academic achievements, and daily life activities are rarely explored. We therefore performed an exploratory study identifying various factors possibly related to the educational scores of these medical students. Questionnaires were sent out to all first preclinical year medical students, with 79.8% being returned (245/307 questionnaires). Positive correlations were revealed between the premedical year grade point average (pre-MD GPA) and anatomy, physiology, and biochemistry scores (R = 0.664, 0.521, and 0.653, respectively, P student satisfaction with anatomy, the percentage of expected reading, monthly earnings, reading after class and near exam time, and duration of sleeping periods near exam time (R = 0.773, R(2) = 0.598, P student satisfaction with biochemistry, and exam performance expectations (R = 0.794, R(2) = 0.630, P satisfaction.

  16. CT-based attenuation correction and resolution compensation for I-123 IMP brain SPECT normal database: a multicenter phantom study.

    Science.gov (United States)

    Inui, Yoshitaka; Ichihara, Takashi; Uno, Masaki; Ishiguro, Masanobu; Ito, Kengo; Kato, Katsuhiko; Sakuma, Hajime; Okazawa, Hidehiko; Toyama, Hiroshi

    2018-03-19

    Statistical image analysis of brain SPECT images has improved diagnostic accuracy for brain disorders. However, the results of statistical analysis vary depending on the institution even when they use a common normal database (NDB), due to different intrinsic spatial resolutions or correction methods. The present study aimed to evaluate the correction of spatial resolution differences between equipment and examine the differences in skull bone attenuation to construct a common NDB for use in multicenter settings. The proposed acquisition and processing protocols were those routinely used at each participating center with additional triple energy window (TEW) scatter correction (SC) and computed tomography (CT) based attenuation correction (CTAC). A multicenter phantom study was conducted on six imaging systems in five centers, with either single photon emission computed tomography (SPECT) or SPECT/CT, and two brain phantoms. The gray/white matter I-123 activity ratio in the brain phantoms was 4, and they were enclosed in either an artificial adult male skull, 1300 Hounsfield units (HU), a female skull, 850 HU, or an acrylic cover. The cut-off frequency of the Butterworth filters was adjusted so that the spatial resolution was unified to a 17.9 mm full width at half maximum (FWHM), that of the lowest resolution system. The gray-to-white matter count ratios were measured from SPECT images and compared with the actual activity ratio. In addition, mean, standard deviation and coefficient of variation images were calculated after normalization and anatomical standardization to evaluate the variability of the NDB. The gray-to-white matter count ratio error without SC and attenuation correction (AC) was significantly larger for higher bone densities (p correction. The proposed protocol showed potential for constructing an appropriate common NDB from SPECT images with SC, AC and spatial resolution compensation.

  17. Studies of Nicotinic Receptors in Non-human Primates Using PET and SPECT

    International Nuclear Information System (INIS)

    Kassiou, M.; University of Sydney,

    2002-01-01

    Full text: Observations of abnormalities in the densities of nicotinic acetylcholine receptors (nAChRs) in the brains of smokers and patients with various CNS disorders has suggested that noninvasive imaging and quantification of nAChRs using PET and SPECT would be useful. This offers further the understanding of the involvement of these receptors in these conditions as well as insight into their role in the normal functioning of the brain. As a prelude to human studies, newly developed PET and SPECT radioligands are first evaluated in animals to determine their suitability for clinical imaging. In the neurosciences the most widespread application of PET and SPECT in animal imaging has been in the study of non-human primates. The larger animals allow the performance of quantitative imaging to be achieved on conventional clinical human scanners. The use of non-human primates for imaging nAChRs in models of Parkinson's disease and smoking is described below. Nicotinic acetylcholine receptors have been implicated in PD's since it has been demonstrated postmortem that cortical nAChRs are reduced and parallel the increase in dementia that occurs in PD patients. In experimental animals it has shown that nicotine protects against MPTP-induced degeneration. MPTP degeneration representing the most widely used and validated animal model of PD. Also, a number of studies have indicated that smokers have a lower than expected incidence of PD, suggesting a protective effect of nicotine. In order to study nAChRs using PET we have developed [ 76 Br]bromoepibatidine. This work was carried out at the Service Hospitalier Frederic Joliot, Orsay France as part of the France-Australia collaboration. In papio papio baboon the brain uptake of [ 76 Br]bromoepibatidine was high with preferential localisation in the thalamus. The [ 76 Br]bromoepibatidine uptake is consistent with the known cerebral nAChR distribution in primates. The radioactivity in thalamus, striatum and cortices was

  18. A comparative study of perfusion CT and 99mTc-Hmpao spect measurement to assess cerebrovascular reserve capacity in patients with internal carotid artery occlusion

    Directory of Open Access Journals (Sweden)

    Eicker S

    2011-11-01

    Full Text Available Abstract Background and purpose Patients with internal carotid artery (ICA occlusion can demonstrate impaired cerebral vascular reserve (CVR. The detection of CVR using single photon emission CT (SPECT is nowadays widely accepted as a predictor in the diagnostic pathway in patients considered for cerebral revascularization. Recently perfusion CT (PCT gained widely acceptance in stroke imaging The present study was aimed at comparing the results of perfusion CT (PCT and 99mTc-HMPAO SPECT with acetazolamide challenge in patients with ICA occlusion. Methods 13 patients were included in the prospective evaluation. Both PCT and 99mTc-HMPAO SPECT were performed before and after the administration of acetazolamide. In detail, regional cerebral blood flow (rCBF, regional cerebral blood volume (rCBV, adapted time to peak (Tmax and mean transit times (MTT were compared with SPECT data. Results 99mTc-HMPAO SPECT demonstrated an impairment of CVR in six patients. A preserved CVR was present in seven patients. All patients with impaired CVR proven by SPECT had a delayed MTT (mean +2.98 s and a delayed Tmax (mean + 5.9 s, (both p Conclusion The prospective study demonstrated a highly significant correlation of perfusion parameters as' detected by 99mTc-HMPAO SPECT and the Tmax as detected by PCT in patients with ICA occlusion. Therefore this easy-to-perform technique seems to be an adequate method for the evaluation of cerebral perfusion in patients with ICA occlusion.

  19. Brain spect imaging

    International Nuclear Information System (INIS)

    Lee, R.G.L.; Hill, T.C.; Holman, B.L.

    1989-01-01

    This paper discusses how the rapid development of single-photon radiopharmaceuticals has given new life to tomographic brain imaging in nuclear medicine. Further developments in radiopharmaceuticals and refinements in neuro-SPECT (single-photon emission computed tomography) instrumentation should help to reinstate brain scintigraphy as an important part of neurologic diagnosis. SPECT of the brain evolved from experimentation using prototype instrumentation during the early 1960s. Although tomographic studies provided superior diagnostic accuracy when compared to planar techniques, the arrival of X-ray CT of the head resulted in the rapid demise of technetium brain imaging

  20. Brain SPECT study of detrusor overactivity and healthy men in urine withholding

    International Nuclear Information System (INIS)

    Yin Yafu; Li Xuena; Li Yaming; Noriyuki Shuke; Atsutaka Okizaki; Junichi Sato; Tamio Aburano

    2009-01-01

    The aim of the study is to identify the brain areas, which control the bladder storage by 99 Tc m -HMPAO SPECT with Neurological Statistical Image Analysis Software (NEUROSTAT). SPECT were performed on twenty-five patients with some storage symptoms of lower urinary tract, among which nineteen patients were with detrusor overactivity (DO) (Group II) and six patients were with normal detrusor function (Group III), and fifteen healthy volunteers (Group I). All the subjects were male and right-handed, and were scanned twice under two conditions: resting state and urine withholding state. NEUROSTAT was adopted to analyze the difference in rCBF between groups and states. The results were displayed on Z-score images at a significance threshold of P<0.05 with correction for multiple comparisons. No region reached significant threshold in comparison of Group II and III in resting state. There were significant increases in tracer activity in bilateral inferior frontal gyri and the right middle temporal gyrus in urine withholding state as compared with resting state in Group I and III (P<0.05 with correction for multiple comparisons, the corresponding Z value was more than 4.476 for Group I, more than 4.414 for Group III). Among the regions,the right inferior frontal gyrus was distinctly prominent at both Z-score and the extent. In Group II, only the left middle temporal gyrus and middle frontal gyrus were activated significantly in urine withholding state as compared with resting (P<0.05 with correction for multiple comparisons, the corresponding Z value was more than 4.35). The results indicated that bilateral inferior frontal gyri and the right middle temporal gyrus associated with the control of bladder storage.Especially, the right inferior frontal gyrus played a more important role in cerebral control of bladder storage, inhibiting the contraction of detrusor in urine storage. (authors)

  1. Quantitative spectral K-edge imaging in preclinical photon-counting x-ray computed tomography.

    Science.gov (United States)

    de Vries, Anke; Roessl, Ewald; Kneepkens, Esther; Thran, Axel; Brendel, Bernhard; Martens, Gerhard; Proska, Roland; Nicolay, Klaas; Grüll, Holger

    2015-04-01

    The objective of this study was to investigate the feasibility and the accuracy of spectral computed tomography (spectral CT) to determine the tissue concentrations and localization of high-attenuation, iodine-based contrast agents in mice. Iodine tissue concentrations determined with spectral CT are compared with concentrations measured with single-photon emission computed tomography (SPECT) and inductively coupled plasma mass spectrometry (ICP-MS). All animal procedures were performed according to the US National Institutes of Health principles of laboratory animal care and were approved by the ethical review committee of Maastricht, The Netherlands. Healthy Swiss mice (n = 4) were injected with an iodinated emulsion radiolabeled with indium as multimodal contrast agent for CT and SPECT. The CT and SPECT scans were acquired using a dedicated small-animal SPECT/CT system. Subsequently, scans were performed with a preclinical spectral CT scanner equipped with a photon-counting detector and 6 energy threshold levels. Quantitative data analysis of SPECT and spectral CT scans were obtained using 3-dimensional volumes-of-interest drawing methods. The ICP-MS on dissected organs was performed to determine iodine uptake per organ and was compared with the amounts determined from spectral CT and SPECT. Iodine concentrations obtained with image-processed spectral CT data correlated well with data obtained either with noninvasive SPECT imaging (slope = 0.96, r = 0.75) or with ICP-MS (slope = 0.99, r = 0.89) in tissue samples. This preclinical proof-of-concept study shows the in vivo quantification of iodine concentrations in tissues using spectral CT. Our multimodal imaging approach with spectral CT and SPECT using radiolabeled iodinated emulsions together with ICP-based quantification allows a direct comparison of all methods. Benchmarked against ICP-MS data, spectral CT in the present implementation shows a slight underestimation of organ iodine concentrations compared

  2. The group study of diagnostic efficacy of cerebro-vascular disease by I-123 IMP SPECT images obtained with ring type SPECT scanner

    International Nuclear Information System (INIS)

    Machida, Kikuo; Honda, Norinari; Matsumoto, Toru

    1991-01-01

    We performed two image reading experiments in order to investigate the diagnostic capability of I-123 IMP SPECT obtained by the ring type SPECT scanner in cerebro-vascular disease. Fourteen physicians diagnosed SPECT images of 55 cases with reference to clinical neurological information, first without brain XCT images and second with XCT images. Each physician detected perfusion defects and redistributions of I-123 IMP and assigned a confidence level of abnormality for these SPECT findings by means of five rating method. From results obtained by ROC analysis, we concluded as follows. (1) Generally, I-123 IMP SPECT is a stable diagnostic modality in the diagnosis of cerebro-vascular disease and the image reading of XCT had no effects on the diagnosis of SPECT on the whole of physician. (2) However, there were unnegligible differences among individuals in the detectability of findings and the effect of XCT image reading. (3) Detectability of redistribution of I-123 IMP was lower than that of perfusion defect and inter-observer variation in the diagnostic performance for redistribution was larger than that of perfusion defect. The results suggest that it is necessary to standardize diagnostic criteria among physicians for redistribution of I-123 IMP. (author)

  3. Simulated Design Strategies for SPECT Collimators to Reduce the Eddy Currents Induced by MRI Gradient Fields

    Science.gov (United States)

    Samoudi, Amine M.; Van Audenhaege, Karen; Vermeeren, Günter; Verhoyen, Gregory; Martens, Luc; Van Holen, Roel; Joseph, Wout

    2015-10-01

    Combining single photon emission computed tomography (SPECT) with magnetic resonance imaging (MRI) requires the insertion of highly conductive SPECT collimators inside the MRI scanner, resulting in an induced eddy current disturbing the combined system. We reduced the eddy currents due to the insert of a novel tungsten collimator inside transverse and longitudinal gradient coils. The collimator was produced with metal additive manufacturing, that is part of a microSPECT insert for a preclinical SPECT/MRI scanner. We characterized the induced magnetic field due to the gradient field and adapted the collimators to reduce the induced eddy currents. We modeled the x-, y-, and z-gradient coil and the different collimator designs and simulated them with FEKO, a three-dimensional method of moments / finite element methods (MoM/FEM) full-wave simulation tool. We used a time analysis approach to generate the pulsed magnetic field gradient. Simulation results show that the maximum induced field can be reduced by 50.82% in the final design bringing the maximum induced magnetic field to less than 2% of the applied gradient for all the gradient coils. The numerical model was validated with measurements and was proposed as a tool for studying the effect of a SPECT collimator within the MRI gradient coils.

  4. Development of PET and SPECT radiopharmaceuticals to study multi-drug resistance (MDR)

    International Nuclear Information System (INIS)

    Katsififs, A.; Dikic, B.; Greguric, I.; Knott, R.; Mattner, F.

    2002-01-01

    Full text: Cellular resistance or Multidrug Resistance (MDR) to cytotoxic agents is the major cause of treatment failure in many human cancers. P-glycoprotein (Pgp), a Mr 17,0000 transmembrane protein and Multi Resistance Protein (MRP) are two proteins that are over expressed and confer resistance to a large number of chemotherapeutic agents by enhancing their extracellular transport. P-glycoprotein is expressed at a relative high level in treated and untreated human malignant tumours, including renal, colonic, adrenal, hepatocellular carcinoma and a considerable percentage of breast carcinomas. 99m Tc-Sestamibi, a lipophilic cationic complex is a transport substrate for Pgp. In clinical studies of human neoplasms it was found that tumour uptake and clearance of this tracer correlate with Pgp expression and may be used for the phenotypic assessment of MDR. However, new tracers with better substrate specificity for Pgp and other drug transporters would greatly assist in optimising chemotherapeutic treatment and improving patient management by predicting tumour response to therapy and to assist in the development of antagonists, which may reverse or halt MDR. The aim of this project is therefore to develop PET and SPECT radiopharmaceuticals with improved affinity and selectivity for Pgp and MRP for the clinical evaluation of MDR in cancer patients. To optimise cellular transport characteristics, a number of chemical families that have been found to be substrates of Pgp and other drug efflux pumps, will be investigated. In the first instance, a series of drugs based on the flavonol natural product, Quercetin will be developed, screened for MDR and radiolabelled with PET and SPECT isotopes. Quercetin and related flavonol derivatives have been selected for this project because of their moderate to good affinity for Pgp. With the assistance of molecular modeling and in vitro studies, structural modification will be undertaken to improve the specificity and affinity for

  5. 99mTc MDP SPECT-CT-Based Modified Mirels Classification for Evaluation of Risk of Fracture in Skeletal Metastasis: A Pilot Study.

    Science.gov (United States)

    Riaz, Saima; Bashir, Humayun; Niazi, Imran Khalid; Butt, Sumera; Qamar, Faisal

    2018-06-01

    Mirels' scoring system quantifies the risk of sustaining a pathologic fracture in osseous metastases of weight bearing long bones. Conventional Mirels' scoring is based on radiographs. Our pilot study proposes Tc MDP bone SPECT-CT based modified Mirels' scoring system and its comparison with conventional Mirels' scoring. Cortical lysis was noted in 8(24%) by SPECT-CT versus 2 (6.3%) on X-rays. Additional SPECT-CT parameters were; circumferential involvement [1/4 (31%), 1/2 (3%), 3/4 (37.5%), 4/4 (28%)] and extra-osseous soft tissue [3%]. Our pilot study suggests the potential role of SPECT-CT in predicting risk of fracture in osseous metastases.

  6. Small Molecular TRAIL Inducer ONC201 Induces Death in Lung Cancer Cells: A Preclinical Study

    OpenAIRE

    Feng, Yuan; Zhou, Jihong; Li, Zhanhua; Jiang, Ying; Zhou, Ying

    2016-01-01

    Tumor necrosis factor (TNF)-related apoptosis-inducing ligand (TRAIL) selectively targets cancer cells. The present preclinical study investigated the anti-cancer efficiency of ONC201, a first-in-class small molecule TRAIL inducer, in lung cancer cells. We showed that ONC201 was cytotoxic and anti-proliferative in both established (A549 and H460 lines) and primary human lung cancer cells. It was yet non-cytotoxic to normal lung epithelial cells. Further, ONC201 induced exogenous apoptosis act...

  7. Study on the primary visual cortex of visually impaired subjects by means of 123I-IMP SPECT and MRI

    International Nuclear Information System (INIS)

    Ishikawa, Nobuyoshi; Satou, Motohiro; Takeda, Tohoru; Itai, Yuji; Nishijo, Kazushi.

    1995-01-01

    We conducted a study of rCBF in the primary visual cortex of visually impaired subjects who have not been subjected to external stimulation for a long period, by means of 123 I-IMP SPECT and MRI. The four subjects had lost their sight due to brain tumors (n=2), glaucoma (n=1) and trauma (n=1). 123 I-IMP SPECT showed no differences between the visually impaired group and a visually sound control group on visual analysis as well as semiquantitative analysis. MRI of the visually impaired subjects showed no organic changes, such as atrophy, in the occipital cortex. In conclusion, visually impaired subjects have no decrease in rCBF and no anatomical changes in the primary visual cortex. (author)

  8. A quantitative study of brain perfusion patterns of 99mTc-ECD SPECT in children with developmental disabilities

    International Nuclear Information System (INIS)

    Hirano, Keiko; Aiba, Hideo; Oguro, Katsuhiko

    2004-01-01

    The aim of this study was to investigate the relationship between developmental disabilities and brain perfusion patterns. We performed technetium-99m-ethylcysteinate dimer ( 99m Tc-ECD) single photon emission computed tomography (SPECT) in 30 children with neurological disorders using the Patlak plot method. In children without developmental disabilities, the distribution of regional cortical perfusion evolved in relation to brain maturation. At one month of age, there was a predominant uptake in the perirolandic cortex. Radionuclide uptake in both the parietal and occipital cortices became evident by three months. Uptake in the temporal and frontal cortex increased by 6 and 11 months, respectively. Brain perfusion showed a pattern similar to that of adults by two years of age at the latest. In children with developmental disabilities, developmental changes of brain perfusion were delayed compared to normally developing children. Brain SPECT is a useful tool to assess the brain maturation in children with developmental disabilities. (author)

  9. Plant-based medicines for anxiety disorders, Part 1: a review of preclinical studies.

    Science.gov (United States)

    Sarris, Jerome; McIntyre, Erica; Camfield, David A

    2013-03-01

    Research in the area of herbal psychopharmacology has revealed a variety of promising medicines that may provide benefit in the treatment of general anxiety and specific anxiety disorders. However, a comprehensive review of plant-based anxiolytics has been absent to date. This article (part 1) reviews herbal medicines for which only preclinical investigations for anxiolytic activity have been performed. In part 2, we review herbal medicines for which there have been clinical investigations for anxiolytic activity. An open-ended, language-restricted (English) search of MEDLINE (PubMed), CINAHL, Scopus and the Cochrane Library databases was conducted (up to 28 October 2012) using specific search criteria to identify herbal medicines that have been investigated for anxiolytic activity. This search of the literature revealed 1,525 papers, from which 53 herbal medicines were included in the full review (having at least one study using the whole plant extract). Of these plants, 21 had human clinical trial evidence (reviewed in part 2), with another 32 having solely preclinical studies (reviewed here in part 1). Preclinical evidence of anxiolytic activity (without human clinical trials) was found for Albizia julibrissin, Sonchus oleraceus, Uncaria rhynchophylla, Stachys lavandulifolia, Cecropia glazioui, Magnolia spp., Eschscholzia californica, Erythrina spp., Annona spp., Rubus brasiliensis, Apocynum venetum, Nauclea latifolia, Equisetum arvense, Tilia spp., Securidaca longepedunculata, Achillea millefolium, Leea indica, Juncus effusus, Coriandrum sativum, Eurycoma longifolia, Turnera diffusa, Euphorbia hirta, Justicia spp., Crocus sativus, Aloysia polystachya, Albies pindrow, Casimiroa edulis, Davilla rugosa, Gastrodia elata, Sphaerathus indicus, Zizyphus jujuba and Panax ginseng. Common mechanisms of action for the majority of botanicals reviewed primarily involve GABA, either via direct receptor binding or ionic channel or cell membrane modulation; GABA transaminase

  10. Dopaminergic dysfunction and psychiatric symptoms in movement disorders: a 123I-FP-CIT SPECT study

    International Nuclear Information System (INIS)

    Di Giuda, Daniela; Cocciolillo, Fabrizio; Bruno, Isabella; Giordano, Alessandro; Camardese, Giovanni; Pucci, Lorella; Janiri, Luigi; Bentivoglio, Anna Rita; Guidubaldi, Arianna; Fasano, Alfonso

    2012-01-01

    Psychiatric symptoms frequently occur in patients with movement disorders. They are not a mere reaction to chronic disability, but most likely due to a combination of psychosocial factors and biochemical dysfunction underlying the movement disorder. We assessed dopamine transporter (DAT) availability by means of 123 I-FP-CIT SPECT, and motor and psychiatric features in patients with Parkinson's disease, primary dystonia and essential tremor, exploring the association between SPECT findings and symptom severity. Enrolled in the study were 21 patients with Parkinson's disease, 14 patients with primary dystonia and 15 patients with essential tremor. The severity of depression symptoms was assessed using the Hamilton depression rating scale, anxiety levels using the Hamilton anxiety rating scale and hedonic tone impairment using the Snaith-Hamilton pleasure scale. Specific 123 I-FP-CIT binding in the caudate and putamen was calculated based on ROI analysis. The control group included 17 healthy subjects. As expected, DAT availability was significantly decreased in patients with Parkinson's disease, whereas in essential tremor and dystonia patients it did not differ from that observed in the control group. In Parkinson's disease patients, an inverse correlation between severity of depression symptoms and DAT availability in the left caudate was found (r = -0.63, p = 0.002). In essential tremor patients, levels of anxiety symptoms were inversely correlated with DAT availability in the left caudate (r = -0.69, p = 0.004). In dystonia patients, the severities of both anxiety and depression symptoms were inversely associated with DAT availability in the left putamen (r = -0.71, p = 0.004, and r = -0.75, p = 0.002, respectively). There were no correlations between psychometric scores and 123 I-FP-CIT uptake ratios in healthy subjects. We found association between presynaptic dopaminergic function and affective symptoms in different movement disorders. Interestingly, the

  11. Benzodiazepine receptor and cerebral blood flow in early Alzheimer's disease. SPECT study using 123I-Iomazenil and 123I-IMP

    International Nuclear Information System (INIS)

    Kitamura, Shin; Koshi, Yasuhiko; Komiyama, Tasuku; Sakayori, Osamu; Komaba, Yuichi; Ohyama, Masashi; Mishina, Masahiro; Tsuganesawa, Toshikazu; Terashi, Akiro

    1996-01-01

    This study was designed to investigate benzodiazepine receptors (BZR) and cerebral blood flow (CBF) in patients with early Alzheimer's disease. Imaging of BZR and measurement of CBF were performed by SPECT using 123 I-Iomazenil (IMZ) and 123 I-IMP respectively, in seven patients with early Alzheimer's disease and five patients with unilateral left cerebral infarction as controls. The values for the normal cerebral hemisphere (ratio to the contralateral cerebellum) in patients with cerebral infarction were adopted as control values. In patients with Alzheimer's disease, the CBF (ratio to cerebellum) decreased significantly in the frontal cortex and the parietal cortex compared with the control values. There was no significant difference in late IMZ SPECT counts (ratio to cerebellum) and washout (the ratio of late-to-early IMZ SPECT counts) between patients with Alzheimer's disease and the controls. However, the late IMZ SPECT counts and washout decreased in one patient with moderate dementia. There was a significant correlation between the severity of dementia and the late IMZ SPECT counts in the temporal cortex and the parietal cortex. These results suggest that benzodiazepine binding sites are relatively well preserved in patients with early Alzheimer's disease, and reduction of the CBF is caused by neuronal dysfunction rather than by neuronal loss. IMZ SPECT study is useful and necessary for clarifying the pathophysiological state in Alzheimer's disease. (author)

  12. Effects of video game playing on cerebral blood flow in young adults: a SPECT study.

    Science.gov (United States)

    Chou, Yuan-Hwa; Yang, Bang-Hung; Hsu, Ju-Wei; Wang, Shyh-Jen; Lin, Chun-Lung; Huang, Kai-Lin; Chien Chang, Alice; Lee, Shin-Min

    2013-04-30

    To study the impact of video game playing on the human brain, the effects of two video games playing on cerebral blood flow (CBF) in young adults were determined. Thirty healthy subjects comprising 18 males and 12 females who were familiar with video game playing were recruited. Each subject underwent three sessions of single photon emission computed tomography (SPECT) with a bolus injection of 20 mCi (99m)Tc ECD IV to measure their CBF. The first measurement was performed as baseline, the second and third measurements were performed after playing two different video games for 30 min, respectively. Statistic parametric mapping (SPM2) with Matlab 6.5 implemented on a personal computer was used for image analysis. CBF was significantly decreased in the prefrontal cortex and significantly increased in the temporal and occipital cortices after both video games playing. Furthermore, decreased CBF in the anterior cingulate cortex (ACC) which was significantly correlated with the number of killed characters was found after the violent game playing. The major finding of hypo-perfusion in prefrontal regions after video game playing is consistent with a previous study showing reduced or abnormal prefrontal cortex functions after video game playing. The second finding of decreased CBF in the ACC after playing the violent video game provides support for a previous hypothesis that the ACC might play a role in regulating violent behavior. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. Evaluation of penetration and scattering components in conventional pinhole SPECT: phantom studies using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Deloar, Hossain M; Watabe, Hiroshi; Aoi, Toshiyuki; Iida, Hidehiro

    2003-01-01

    In quantitative pinhole SPECT, photon penetration through the collimator edges (penetration), and photon scattering by the object (object scatter) and collimator (collimator scatter) have not been investigated rigorously. Monte Carlo simulation was used to evaluate these three physical processes for different tungsten knife-edge pinhole collimators using uniform, hotspot and donut phantoms filled with 201 Tl, 99m Tc, 123 I and 131 I solutions. For the hotspot phantom, the penetration levels with respect to total counts for a 1 mm pinhole aperture were 78%, 28% and 23% for 131 I, 123 I and 99m Tc, respectively. For a 2 mm aperture, these values were 65% for 131 I, 16% for 123 I and 12% for 99m Tc. For all pinholes, 201 Tl penetration was less than 4%. The evaluated scatter (from object and collimator) with a hotspot phantom for the 1 mm pinhole was 24%, 16%, 18% and 13% for 201 Tl, 99m Tc, 123 I and 131 I, respectively. Summation of the object and collimator scatter for the uniform phantom was approximately 20% higher than that for the hotspot phantom. Significant counts due to penetration and object and collimator scatter in the reconstructed image were observed inside the core of the donut phantom. The collimator scatter can be neglected for all isotopes used in this study except for 131 I. Object scatter correction for all radionuclides used in this study is necessary and correction for the penetration contribution is necessary for all radionuclides but 201 Tl

  14. A SPECT study of language and brain reorganization three years after pediatric brain injury.

    Science.gov (United States)

    Chiu Wong, Stephanie B; Chapman, Sandra B; Cook, Lois G; Anand, Raksha; Gamino, Jacquelyn F; Devous, Michael D

    2006-01-01

    Using single photon emission computed tomography (SPECT), we investigated brain plasticity in children 3 years after sustaining a severe traumatic brain injury (TBI). First, we assessed brain perfusion patterns (i.e., the extent of brain blood flow to regions of the brain) at rest in eight children who suffered severe TBI as compared to perfusion patterns in eight normally developing children. Second, we examined differences in perfusion between children with severe TBI who showed good versus poor recovery in complex discourse skills. Specifically, the children were asked to produce and abstract core meaning for two stories in the form of a lesson. Inconsistent with our predictions, children with severe TBI showed areas of increased perfusion as compared to normally developing controls. Adult studies have shown the reverse pattern with TBI associated with reduced perfusion. With regard to the second aim and consistent with previously identified brain-discourse relations, we found a strong positive association between perfusion in right frontal regions and discourse abstraction abilities, with higher perfusion linked to better discourse outcomes and lower perfusion linked to poorer discourse outcomes. Furthermore, brain-discourse patterns of increased perfusion in left frontal regions were associated with lower discourse abstraction ability. The results are discussed in terms of how brain changes may represent adaptive and maladaptive plasticity. The findings offer direction for future studies of brain plasticity in response to neurocognitive treatments.

  15. Cerebral perfusion changes in traumatic diffuse brain injury. IMP SPECT studies

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Kawashima, Ryuta; Fukuda, Hiroshi; Ishii, Kiyoshi; Onuma, Takehide.

    1997-01-01

    Diffuse brain injury (DBI) is characterized by axonal degeneration and neuronal damage which cause diffuse brain atrophy. We have investigated the time course of abnormalities in cerebral perfusion distribution in cases of DBI by using Iodine-123-IMP SPECT, and the relationship to the appearance of diffuse brain atrophy. SPECT scans were performed on eight patients with diffuse brain injury due to closed cranial trauma in acute and chronic stages. All patients showed abnormalities in cerebral perfusion with decreases in perfusion, even in non-depicted regions on MRI, and the affected areas varied throughout the period of observation. Diffuse brain atrophy appeared in all patients. In some patients, diffuse brain atrophy was observed at or just after the time when the maximum number of lesions on SPECT were seen. The abnormalities in cerebral perfusion in cases of DBI might therefore be related to axonal degeneration and neuronal damage which causes diffuse brain atrophy. (author)

  16. Upregulated GABA Inhibitory Function in ADHD Children with Child Behavior Checklist–Dysregulation Profile: 123I-Iomazenil SPECT Study

    Science.gov (United States)

    Nagamitsu, Shinichiro; Yamashita, Yushiro; Tanigawa, Hitoshi; Chiba, Hiromi; Kaida, Hayato; Ishibashi, Masatoshi; Kakuma, Tatsuyuki; Croarkin, Paul E.; Matsuishi, Toyojiro

    2015-01-01

    The child behavior checklist–dysregulation profile (CBCL–DP) refers to a pattern of elevated scores on the attention problems, aggression, and anxiety/depression subscales of the child behavior checklist. The aim of the present study was to investigate the potential role of GABA inhibitory neurons in children with attention deficit/hyperactivity disorder (ADHD) and dysregulation assessed with a dimensional measure. Brain single photon emission computed tomography (SPECT) was performed in 35 children with ADHD using 123I-iomazenil, which binds with high affinity to benzodiazepine receptors. Iomazenil binding activities were assessed with respect to the presence or absence of a threshold CBCL–DP (a score ≥210 for the sum of the three subscales: Attention Problems, Aggression, and Anxiety/Depression). We then attempted to identify which CBCL–DP subscale explained the most variance with respect to SPECT data, using “age,” “sex,” and “history of maltreatment” as covariates. Significantly higher iomazenil binding activity was seen in the posterior cingulate cortex (PCC) of ADHD children with a significant CBCL–DP. The Anxiety/Depression subscale on the CBCL had significant effects on higher iomazenil binding activity in the left superior frontal, middle frontal, and temporal regions, as well as in the PCC. The present brain SPECT findings suggest that GABAergic inhibitory neurons may play an important role in the neurobiology of the CBCL–DP, in children with ADHD. PMID:26082729

  17. In vivo SPECT reporter gene imaging of regulatory T cells.

    Directory of Open Access Journals (Sweden)

    Ehsan Sharif-Paghaleh

    Full Text Available Regulatory T cells (Tregs were identified several years ago and are key in controlling autoimmune diseases and limiting immune responses to foreign antigens, including alloantigens. In vivo imaging techniques including intravital microscopy as well as whole body imaging using bioluminescence probes have contributed to the understanding of in vivo Treg function, their mechanisms of action and target cells. Imaging of the human sodium/iodide symporter via Single Photon Emission Computed Tomography (SPECT has been used to image various cell types in vivo. It has several advantages over the aforementioned imaging techniques including high sensitivity, it allows non-invasive whole body studies of viable cell migration and localisation of cells over time and lastly it may offer the possibility to be translated to the clinic. This study addresses whether SPECT/CT imaging can be used to visualise the migratory pattern of Tregs in vivo. Treg lines derived from CD4(+CD25(+FoxP3(+ cells were retrovirally transduced with a construct encoding for the human Sodium Iodide Symporter (NIS and the fluorescent protein mCherry and stimulated with autologous DCs. NIS expressing self-specific Tregs were specifically radiolabelled in vitro with Technetium-99m pertechnetate ((99mTcO(4(- and exposure of these cells to radioactivity did not affect cell viability, phenotype or function. In addition adoptively transferred Treg-NIS cells were imaged in vivo in C57BL/6 (BL/6 mice by SPECT/CT using (99mTcO(4(-. After 24 hours NIS expressing Tregs were observed in the spleen and their localisation was further confirmed by organ biodistribution studies and flow cytometry analysis. The data presented here suggests that SPECT/CT imaging can be utilised in preclinical imaging studies of adoptively transferred Tregs without affecting Treg function and viability thereby allowing longitudinal studies within disease models.

  18. Dynamic study on cerebral perfusion of the pentylenetetrazol kindling cats by SPECT

    International Nuclear Information System (INIS)

    Hou Min; Liu Xingdang; Wang Kaiyan

    2004-01-01

    Objective: To learn the change of cerebral perfusion in the pentylenetetrazol kindling cats during the development of epilepsy. Methods: firstly, we performed 12 basic 99m Tc- ethyl cysteinate dimmer (ECD) SPECT as auto-control before the cats were made into epileptic models. Then, according to seizure level of epileptic model, SPECT was performed when the cats began to seizure in the form of facial tic(level 1), nodding spasm (level 2), limb tonic seizures (level 3) and generalized tonic-clonic seizures(level 4). At the same time, we detected the EEG at each level of seizure in order to contrast with SPECT findings. Results:There is no abnormal SPECT finding of cats before using PTZ. The SPECT at each level of kindling: hyperperfusion in forehead and basal ganglia at level 1; more evident hyperperfusion in forehead at level 2; the hyperperfusion in forehead being weakened and another hyperperfusion appearing in deep parietal lobe at level 3; the hyperperfusion in forehead disappearing and the hyperfusion in deep parietal lobe becoming more obvious and a hypoperfusion beside it appearing at level 4. As the time going on, the hyperperfusion disappeared completely and the hypoperfusion became more and more clear. The SPECT findings are coincided with EEG findings. Conclusion: 1. During the kindling of cats, a regional hyperperfusion appeared in the cats' brain: at the stage of focal seizure, the cerebral perfusion increased in forehead and ganglia; at the stage of generalized seizure, the hyperperfusion region gradually moved from forehead to deep parietal lobe. 2. Once the model animal was completely kindled, there would be a fixed hypoperfusion region instead, which may be the epileptic focus. (authors)

  19. Visuo-Spatial Imagery Impairment in Posterior Cortical Atrophy: A Cognitive and SPECT Study

    Directory of Open Access Journals (Sweden)

    Simona Gardini

    2011-01-01

    Full Text Available This study investigated the cognitive profile and the cerebral perfusion pattern in a highly educated 70 year old gentleman with posterior cortical atrophy (PCA. Visuo-perceptual abilities, spatial memory, spatial representation and navigation, visuo-spatial mental imagery, semantic and episodic-autobiographical memory were assessed. Regional cerebral blood flow (rCBF was imaged with SPECT. Cognitive testing showed visual-perceptual impairment, apperceptive visual and landmark agnosia, topographical disorientation with way-finding deficits, impaired map learning and poor mental image generation. Semantic memory was normal, while episodic-autobiographical memory was impaired. Reduced rCBF was found mainly in the right hemisphere, in the precentral gyrus, posterior cingulate and middle temporal gyri, cuneus and precuneus, in the left superior temporal and lingual gyri and in the parahippocampus bilaterally. Hypoperfusion in occipito-parietal regions was associated with visuo-spatial deficits, whereas deficits in visuo-spatial mental imagery might reflect dysfunction related to hypoperfusion in the parahippocampus and precuneus, structures which are responsible for spatial and imagery processing. Dissociating performance between preserved semantic memory and poor episodic-autobiographical recall is consistent with a pattern of normal perfusion in frontal and anterior temporal regions but abnormal rCBF in the parahippocampi. The present findings indicate that PCA involves visuo-spatial imagery deficits and provide further validation to current neuro-cognitive models of spatial representation and topographical disorientation.

  20. PET AND SPECT STUDIES IN CHILDREN WITH HEMISPHERIC LOW-GRADE GLIOMAS

    Science.gov (United States)

    Juhász, Csaba; Bosnyák, Edit

    2016-01-01

    Molecular imaging is playing an increasing role in the pre-treatment evaluation of low-grade gliomas. While glucose positron emission tomography (PET) can be helpful to differentiate low-grade from high-grade tumors, PET imaging with amino acid radiotracers has several advantages, such as better differentiation between tumors and non-tumorous lesions, optimized biopsy targeting and improved detection of tumor recurrence. This review provides a brief overview of single photon emission computed tomography (SPECT) studies followed by a more detailed review of clinical applications of glucose and amino acid PET imaging in low-grade hemispheric gliomas. We discuss key differences in the performance of the most commonly utilized PET radiotracers and highlight the advantage of PET/MRI fusion to obtain optimal information about tumor extent, heterogeneity and metabolism. Recent data also suggest that simultaneous acquisition of PET/MR images and the combination of advanced MRI techniques with quantitative PET can further improve the pre- and post-treatment evaluation of pediatric brain tumors. PMID:27659825

  1. Culturated rat cerebral cortex explants and their application in the study of SPECT scan radiopharaceuticals

    International Nuclear Information System (INIS)

    Jong, B.M. de.

    1989-01-01

    In this thesis mechanics that result in the distinct localization of radiopharmaceuticals within the brain have been investigated. In order to 'get more insight' in uptake and binding of radiopharmaceuticals bu brain tissue, use has been made of the tissue culture technique. Tissue culture privides the opportunity of doing experiments with brain tissue under stable conditions, in the absence of a blood-brain barrier, and without interference by cerebral blood flow. The present thesis is presented in two sections. The first part focusses on longterm culture of 'organotypic' cerebral neocortex tissue, obtained from neonatal rat brain and explanted into a chemically defined medium. Procedures were developed which enabled culturing of this tissue without the occurence of central necrosis and with the preservation of a characteristic histiotypic organization. Morphological characteristics of the cultures were described and measured at various ages in vitro. In the second part, the cultures were used to study mechanisms that might contribute to the tissue uptake of radiopharmaceuticals which are in clinical use for SPECT brain imaging. (author). 369 refs.; 50 figs.; 13 tabs

  2. A study of 99mTc-HM-PAO brain SPECT in the senile parkinson's disease

    International Nuclear Information System (INIS)

    Chen Wenxin; Lin Xiangtong; Song Wenzhong; Liu Yongchang

    1996-01-01

    Thirty-three cases of senile Parkinson's disease (PD) imaged by 99m Tc-HM-PAO brain SPECT were reported. 66.7% of the patients had cortical hypoperfusion and 18.2% showed asymmetrical hypoperfusion in the basal ganglia. Such a finding was not related with the Hoehn-Yahr stage and the laterality of motor symptoms. If complicated with dementia, the SPECT brain imaging showed similar pattern in Alzheimer's disease with diffuse hypoperfusion in cortical area reflecting widespread pathological changes in tremor paralysis

  3. U-SPECT-BioFluo : An integrated radionuclide, bioluminescence, and fluorescence imaging platform

    NARCIS (Netherlands)

    Van Oosterom, M.N.; Kreuger, R.; Buckle, T.; Mahn, W.A.; Bunschoten, A.; Josephson, L.; Van Leeuwen, F.W.B.; Beekman, F.J.

    2014-01-01

    Background: In vivo bioluminescence, fluorescence, and single-photon emission computed tomography (SPECT) imaging provide complementary information about biological processes. However, to date these signatures are evaluated separately on individual preclinical systems. In this paper, we introduce a

  4. Polymeric micelles for ocular drug delivery: From structural frameworks to recent preclinical studies.

    Science.gov (United States)

    Mandal, Abhirup; Bisht, Rohit; Rupenthal, Ilva D; Mitra, Ashim K

    2017-02-28

    Effective intraocular drug delivery poses a major challenge due to the presence of various elimination mechanisms and physiological barriers that result in low ocular bioavailability after topical application. Over the past decades, polymeric micelles have emerged as one of the most promising drug delivery platforms for the management of ocular diseases affecting the anterior (dry eye syndrome) and posterior (age-related macular degeneration, diabetic retinopathy and glaucoma) segments of the eye. Promising preclinical efficacy results from both in-vitro and in-vivo animal studies have led to their steady progression through clinical trials. The mucoadhesive nature of these polymeric micelles results in enhanced contact with the ocular surface while their small size allows better tissue penetration. Most importantly, being highly water soluble, these polymeric micelles generate clear aqueous solutions which allows easy application in the form of eye drops without any vision interference. Enhanced stability, larger cargo capacity, non-toxicity, ease of surface modification and controlled drug release are additional advantages with polymeric micelles. Finally, simple and cost effective fabrication techniques render their industrial acceptance relatively high. This review summarizes structural frameworks, methods of preparation, physicochemical properties, patented inventions and recent advances of these micelles as effective carriers for ocular drug delivery highlighting their performance in preclinical studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Preclinical Safety Studies of Enadenotucirev, a Chimeric Group B Human-Specific Oncolytic Adenovirus

    Directory of Open Access Journals (Sweden)

    Sam Illingworth

    2017-06-01

    Full Text Available Enadenotucirev is an oncolytic group B adenovirus identified by a process of bio-selection for the ability to selectively propagate in and rapidly kill carcinoma cells. It is resistant to inactivation by human blood components, potentially enabling intravenous dosing in patients with metastatic cancer. However, there are no known permissive animal models described for group B adenoviruses that could facilitate a conventional approach to preclinical safety studies. In this manuscript, we describe our tailored preclinical strategy designed to evaluate the key biological properties of enadenotucirev. As enadenotucirev does not replicate in animal cells, a panel of primary human cells was used to evaluate enadenotucirev replication selectivity in vitro, demonstrating that virus genome levels were >100-fold lower in normal cells relative to tumor cells. Acute intravenous tolerability in mice was used to assess virus particle-mediated toxicology and effects on innate immunity. These studies showed that particle toxicity could be ameliorated by dose fractionation, using an initial dose of virus to condition the host such that cytokine responses to subsequent doses were significantly attenuated. This, in turn, supported the initiation of a phase I intravenous clinical trial with a starting dose of 1 × 1010 virus particles given on days 1, 3, and 5.

  6. Biological basis of sex differences in drug abuse: preclinical and clinical studies.

    Science.gov (United States)

    Lynch, Wendy J; Roth, Megan E; Carroll, Marilyn E

    2002-11-01

    The recent focus on drug abuse in women has brought attention to numerous differences between women and men. In this review, we discuss both preclinical and clinical findings of sex differences in drug abuse as well as mechanisms that may underlie these differences. Recent evidence suggests that the progression to dependence and abuse may differ between women and men; thus, different prevention and treatment strategies may be required. Similar sex differences in drug sensitivity and self-administration have been reported in laboratory animal studies. Females appear to be more vulnerable than males to the reinforcing effects of psychostimulants, opiates, and nicotine during many phases of the addiction process (e.g. acquisition, maintenance, dysregulation-escalation, relapse). Male and female animals differ in their behavioral, neurological, and pharmacological responses to drugs. Although the role of sex in the mechanisms of drug action remains unclear, preclinical and clinical studies indicate that ovarian hormones, particularly estrogen, play a role in producing sex differences in drug abuse. Future research is necessary to provide information on how to design more effective drug abuse treatment programs and resources that are sex specific.

  7. Establishment study of the in vivo imaging analysis with small animal imaging modalities (micro-PET and micro-SPECT/CT) for bio-drug development

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Beomsu; Park, Sanghyeon; Park, Jeonghoon; Jo, Sungkee; Jung, Uhee; Kim, Seolwha; Lee, Yunjong; Choi, Daeseong

    2011-01-15

    In this study, we established the image acquisition and analysis procedures of micro-PET, SPECT/CT using the experimental animal (mouse) for the development of imaging assessment method for the bio-drug. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with {sup 99m}Tc-MDP, DMSA, and {sup 18}F-FDG. SPECT imaging studies using 3 types of pinhole collimators. 5-MWB collimator was used for SPECT image study. To study whole-body distribution, {sup 99m}Tc-MDP SPECT image study was performed. We obtained the fine distribution image. And the CT images was obtained to provide the anatomical information. And then these two types images are fused. To study specific organ uptake, we examined {sup 99}mTc-DMSA SPECT/CT imaging study. We also performed the PET image study using U87MG tumor bearing mice and {sup 18}F-FDG. The overnight fasting, warming and anesthesia with 2% isoflurane pretreatment enhance the tumor image through reducing the background uptake including brown fat, harderian gland and skeletal muscles. Also we got the governmental approval for use of x-ray generator for CT and radioisotopes as sealed and open source. We prepared the draft of process procedure for the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug.

  8. The current status of SPECT or SPECT/CT in South Korea

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Ik Dong; Choi, Eun Kyung; Chung, Yong An [Dept. of Radiology, Incheon Saint Mary' s HospitalThe Catholic University of Korea, Incheon (Korea, Republic of)

    2017-06-15

    The first step to nuclear medicine in Korea started with introduction of the gamma camera in 1969. Although planar images with the gamma camera give important functional information, they have the limitations that result from 2-dimensional images. Single-photon emission computed tomography (SPECT) due to its 3-dimensional image acquisition is superior to earlier planar gamma imaging in image resolution and diagnostic accuracy. As demand for a hybrid functional and anatomical imaging device has increased, integrated SPECT/CT systems have been used. In Korea, SPECT/CT was for the first time installed in 2003. SPECT/CT can eliminate many possible pitfalls on SPECT-alone images, making better attenuation correction and thereby improving image quality. Therefore, SPECT/CT is clinically preferred in many hospitals in various aspects. More recently, additional SPECT/CT images taken from the region with equivocal uptake on planar images have been helpful in making precise interpretation as part of their clinical workup in postoperative thyroid cancer patients. SPECT and SPECT/CT have various advantages, but its clinical application has gradually decreased in recent few years. While some researchers investigated the myocardial blood flow with cardiac PET using F-18 FDG or N-13 ammonia, myocardial perfusion SPECT is, at present, the radionuclide imaging study of choice for the risk stratification and guiding therapy in the coronary artery disease patients in Korea. New diagnostic radiopharmaceuticals for AD have received increasing attention; nevertheless, brain SPECT will remain the most reliable modality evaluating cerebral perfusion.

  9. Comparative analysis of the sensitivity of the scanner rSPECT: using GAMOS: a Geant4-based framework

    International Nuclear Information System (INIS)

    Martinez Turtos, Rosana; Diaz Garcia, Angelina; Abreu Alfonso, Yamiel; Arteche, Jossue; Leyva Pernia, Diana

    2012-01-01

    The molecular imaging of cellular processes in vivo using preclinical animal studies and SPECT technique is one of the main reasons for the design of new devices with high spatial resolution. As an auxiliary tool, Monte Carlo simulation has allowed the characterization and optimization of those medical imaging systems effectively. At present there is a new simulation framework called GAMOS (GEANT4-based Architecture for Medicine-Oriented Simulations); which code, libraries and particle transport method correspond to those developed by GEANT4 and contains specific applications for nuclear medicine. This tool has been already validated for PET technique by comparison with experimental data, while not yet been done the correct evaluation of GAMOS for SPECT systems. Present work have demonstrated the potential of GAMOS in obtaining simulated realistic data using this nuclear imaging technique. For this purpose, simulation of a novel installation 'rSPECT' ,dedicated to the study of rodents, has been done. The study comprises the collimation and detection geometries and the fundamental characteristics of the previous published experimental measurements for rSPECT installation. Studies have been done using 99mTc and 20% energy window. Sensitivity values obtained by simulation revealed an acceptable agreement with experimental values. Therefore we can conclude that simulation results have shown good agreement with the real data. This fact allowed to estimate the behavior of the new GEANT4 simulation platform 'GAMOS' in SPECT applications and have demonstrated the feasibility of reproducing experimental data. (author)

  10. Dopamine transporter density by [99mTc]-TRODAT-1 SPECT and neurocognitive performance - a preliminary pilot study

    International Nuclear Information System (INIS)

    Shih, Ming C; Amaro, Edson Jr; Souza, Sayuri de E

    2006-01-01

    Introduction: Cognitive deficits are associated with functional impairment as well as with poor quality of life in Parkinson's disease (PD). The main brain alteration in PD is a progressive loss of nigrostriatal dopamine neurons. Both animal and human studies have demonstrated that basal ganglia dopamine system is important for cognitive and motor functioning. Dopamine transporter (DAT) PET and SPECT radiotracers have been successfully used to estimate, in vivo, dopamine neuronal loss in humans. Objectives: The present study is aimed to examine the relationship between cognitive impairment and striatal dopamine neuronal loss, as estimated by [ 99m Tc]-TRODAT-1 SPECT in PD patients. Methods: Fifteen PD patients were scanned with [ 99m Tc]-TRODAT-1 SPECT (Dual-Head-SPECT Hwakeye, GE). SPECT images were reconstructed with FBP and Butterworth filter 0,40c/px order 10. Regions of interest (ROIs) were striatum (STR) and occipital lobe (BKG nonspecific binding) and were delineated in 3-mm transaxials slices analyzed according to this formula BP=([STR-BKG]/BKG), where BP is the striatal DAT binding potential. Neurocognitive tests, including the Rey Auditory Verbal Learning Test, Wisconsin Card Sorting Test, Ravens Progressive Matrices, Digit Span and Tavis 3, were applied to all subjects by trained neuropsychologists. Results: Striatal DAT binding potential (BP) was negatively correlated with the RAVLT tests 4 (R= 0.57, p≤0.05) and 5 (R=0.57, p≤0.05), which evaluate verbal learning. Striatal DAT BP was also negatively correlated with the WCST learning item (R=0.54, p≤0.05) and the Tavis 3 items, action error (R=0.52, p≤0.05) and number of correct responses (R=0.47, p≤0.05). Conclusions: Although preliminary, the present findings suggest that striatal DAT loss is associated with a poorer performance on verbal learning and cognitive flexibility tasks. These results are in line with a previous study that examined healthy volunteers and found a relationship between

  11. Advanced Pre-clinical Research Approaches and Models to Studying Pediatric Anesthetic Neurotoxicity

    Directory of Open Access Journals (Sweden)

    Cheng eWang

    2012-10-01

    Full Text Available Advances in pediatric and obstetric surgery have resulted in an increase in the duration and complexity of anesthetic procedures. A great deal of concern has recently arisen regarding the safety of anesthesia in infants and children. Because of obvious limitations, it is not possible to thoroughly explore the effects of anesthetic agents on neurons in vivo in human infants or children. However, the availability of some advanced pre-clinical research approaches and models, such as imaging technology both in vitro and in vivo, stem cell and nonhuman primate experimental models, have provided potentially invaluable tools for examining the developmental effects of anesthetic agents. This review discusses the potential application of some sophisticaled research approaches, e.g., calcium imaging, in stem cell-derived in vitro models, especially human embryonic neural stem cells, along with their capacity for proliferation and their potential for differentiation, to dissect relevant mechanisms underlying the etiology of the neurotoxicity associated with developmental exposures to anesthetic agents. Also, this review attempts to discuss several advantages for using the developing rhesus monkey models (in vivo, when combined with dynamic molecular imaging approaches, in addressing critical issues related to the topic of pediatric sedation/anesthesia. These include the relationships between anesthetic-induced neurotoxicity, dose response, time-course and developmental stage at time of exposure (in vivo studies, serving to provide the most expeditious platform toward decreasing the uncertainty in extrapolating pre-clinical data to the human condition.

  12. Clinical evaluation of stress thallium spect in ischemic heart disease

    International Nuclear Information System (INIS)

    Sui, Osamu; Kimura, Nazuna; Soeki; Takeshi; Takeichi, Naoki; Shinohara, Hisanori; Tamura, Yoshiyuki; Fukuda, Nobuo

    1997-01-01

    Thallium SPECT was performed in patients with significant coronary artery stenosis, 67 cases were after maximal exercise and 74 cases were during coronary vasodilation induced by ATP (adenosine triphosphate) infusion. In patients suspected of angina pectoris, the sensitivity, specificity and predictive accuracy for detection of coronary artery disease (CAD) were 88%, 78% and 82% for exercise SPECT, and 100%, 72% and 84% for ATP SPECT studies, respectively. In patients with old myocardial infarction, these were 73%, 100% and 88% for exercise SPECT and 71%, 100% and 81% for ATP SPECT. These were 75%, 49% and 60% for treadmill exercise test in the patient group including both angina and myocardial infarction. For detection of diseased vessels, the diagnostic accuracy for left anterior descending artery and right coronary artery lesions was almost equal for ATP and exercise SPECT study, but ATP SPECT study was more sensitive than exercise SPECT study in detection of left circumflex artery lesions. ATP as well as exercise SPECT studies occasionally gave false positive results in patients with single-vessel disease. ATP as well as exercise SPECT studies underestimated the severity of multi-vessel disease. In general, the results of ATP SPECT imaging were highly concordant with the results of exercise SPECT imaging. ATP stress thallium SPECT imaging provided a safe and highly accurate diagnostic tool for detection of CAD. (author)

  13. Subendocardial versus transmural ischaemia in myocardial perfusion SPECT--a Monte Carlo study

    DEFF Research Database (Denmark)

    Bartosik, Jolanta; El-Ali, Henrik Hussein; Nilsson, Ulf

    2006-01-01

    Myocardial perfusion imaging with single-photon emission computed tomography (SPECT) is useful for the evaluation of patients with known or suspected coronary artery disease. Parameters of interest are the reduction in the blood perfusion (severity) and the lesion volume (extent). The aim of this...

  14. Study of factors affecting thyroid volume determination by SPECT and preliminary clinical application

    International Nuclear Information System (INIS)

    Chen Yan

    1992-01-01

    Volumes of 7 thyroid phantoms (12-113.4 ml) and 25 thyroids of hyperthyroid patients were determined using TOSHIBA GCA-901A SPECT scanner. Accuracy of calculated volumes was strongly affected by the spatial resolution, total counts of acquisition and the threshold of background subtraction which depended on the thyroid size and the type of collimator used

  15. SPECT myocardial blood flow quantitation toward clinical use: a comparative study with {sup 13}N-Ammonia PET myocardial blood flow quantitation

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Bailing [University of Missouri-Columbia, Nuclear Science and Engineering Institute, Columbia, Missouri (United States); Hu, Lien-Hsin; Yang, Bang-Hung; Ting, Chien-Hsin; Huang, Wen-Sheng [Taipei Veterans General Hospital, Department of Nuclear Medicine, Taipei (China); Chen, Lung-Ching [Shin Kong Wu-Ho Su Memorial Hospital, Division of Cardiology, Taipei (China); Chen, Yen-Kung [Shin Kong Wu-Ho Su Memorial Hospital, Department of Nuclear Medicine, Taipei (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Changhua (China); Wu, Tao-Cheng [National Yang-Ming University, Cardiovascular Research Center, Taipei (China)

    2017-01-15

    The aim of this study was to evaluate the accuracy of myocardial blood flow (MBF) quantitation of {sup 99m}Tc-Sestamibi (MIBI) single photon emission computed tomography (SPECT) compared with {sup 13}N-Ammonia (NH3) position emission tomography (PET) on the same cohorts. Recent advances of SPECT technologies have been applied to develop MBF quantitation as a promising tool to diagnose coronary artery disease (CAD) for areas where PET MBF quantitation is not available. However, whether the SPECT approach can achieve the same level of accuracy as the PET approach for clinical use still needs further investigations. Twelve healthy volunteers (HVT) and 16 clinical patients with CAD received both MIBI SPECT and NH3 PET flow scans. Dynamic SPECT images acquired with high temporary resolution were fully corrected for physical factors and processed to quantify K1 using the standard compartmental modeling. Human MIBI tracer extraction fraction (EF) was determined by comparing MIBI K1 and NH3 flow on the HVT group and then used to convert flow values from K1 for all subjects. MIBI and NH3 flow values were systematically compared to validate the SPECT approach. The human MIBI EF was determined as [1.0-0.816*exp(-0.267/MBF)]. Global and regional MBF and myocardial flow reserve (MFR) of MIBI SPECT and NH3 PET were highly correlated for all subjects (global R{sup 2}: MBF = 0.92, MFR = 0.78; regional R{sup 2}: MBF ≥ 0.88, MFR ≥ 0.71). No significant differences for rest flow, stress flow, and MFR between these two approaches were observed (All p ≥ 0.088). Bland-Altman plots overall revealed small bias between MIBI SPECT and NH3 PET (global: ΔMBF = -0.03Lml/min/g, ΔMFR = 0.07; regional: ΔMBF = -0.07 - 0.06, ΔMFR = -0.02 - 0.22). Quantitation with SPECT technologies can be accurate to measure myocardial blood flow as PET quantitation while comprehensive imaging factors of SPECT to derive the variability between these two approaches were fully addressed and corrected

  16. SPECT myocardial blood flow quantitation toward clinical use: a comparative study with "1"3N-Ammonia PET myocardial blood flow quantitation

    International Nuclear Information System (INIS)

    Hsu, Bailing; Hu, Lien-Hsin; Yang, Bang-Hung; Ting, Chien-Hsin; Huang, Wen-Sheng; Chen, Lung-Ching; Chen, Yen-Kung; Hung, Guang-Uei; Wu, Tao-Cheng

    2017-01-01

    The aim of this study was to evaluate the accuracy of myocardial blood flow (MBF) quantitation of "9"9"mTc-Sestamibi (MIBI) single photon emission computed tomography (SPECT) compared with "1"3N-Ammonia (NH3) position emission tomography (PET) on the same cohorts. Recent advances of SPECT technologies have been applied to develop MBF quantitation as a promising tool to diagnose coronary artery disease (CAD) for areas where PET MBF quantitation is not available. However, whether the SPECT approach can achieve the same level of accuracy as the PET approach for clinical use still needs further investigations. Twelve healthy volunteers (HVT) and 16 clinical patients with CAD received both MIBI SPECT and NH3 PET flow scans. Dynamic SPECT images acquired with high temporary resolution were fully corrected for physical factors and processed to quantify K1 using the standard compartmental modeling. Human MIBI tracer extraction fraction (EF) was determined by comparing MIBI K1 and NH3 flow on the HVT group and then used to convert flow values from K1 for all subjects. MIBI and NH3 flow values were systematically compared to validate the SPECT approach. The human MIBI EF was determined as [1.0-0.816*exp(-0.267/MBF)]. Global and regional MBF and myocardial flow reserve (MFR) of MIBI SPECT and NH3 PET were highly correlated for all subjects (global R"2: MBF = 0.92, MFR = 0.78; regional R"2: MBF ≥ 0.88, MFR ≥ 0.71). No significant differences for rest flow, stress flow, and MFR between these two approaches were observed (All p ≥ 0.088). Bland-Altman plots overall revealed small bias between MIBI SPECT and NH3 PET (global: ΔMBF = -0.03Lml/min/g, ΔMFR = 0.07; regional: ΔMBF = -0.07 - 0.06, ΔMFR = -0.02 - 0.22). Quantitation with SPECT technologies can be accurate to measure myocardial blood flow as PET quantitation while comprehensive imaging factors of SPECT to derive the variability between these two approaches were fully addressed and corrected. (orig.)

  17. HMPAO-SPECT in cerebral seizures

    International Nuclear Information System (INIS)

    Gruenwald, F.; Bockisch, A.; Reichmann, K.; Ammari, B.; Hotze, A.; Biersack, H.J.; Durwen, H.; Buelau, P.; Elger, C.E.; Rohde, A.; Penin, H.

    1988-01-01

    In nine patients with suspected psychogenic seizures and in three patients with proven epileptic seizures HMPAO-SPECT was performed prior to and during seizure. In the patients with lateron-proven psychogenic seizures no, or only slight, changes of regional cerebral blood flow were found. Patients with proven epilepsy revealed partly normal findings interictally but during seizure a markedly increased circumscript blood flow was found in all patients. Even though PET is superior to SPECT with respect to spatial resolution, in the diagnosis of seizures HMPAO-SPECT has the advantage of enabling injection of the tracer during the seizure and the performance of the SPECT study subsequently. (orig.) [de

  18. Mnemonic activation by SPECT

    International Nuclear Information System (INIS)

    Migneco, O.; Darcourt, J.; Benoit, M; Malandain, G.; Thirion, J.P.; Robert, Ph.; Vidal, R.; Desvignes, Ph.; Benoliel, J.; Ayache, N.; Bussiere, F.

    1997-01-01

    Data of literature show that SPECT is able to detect cerebral activations induced by sensory-motor stimuli. The facts are not clearly established in what concerns the cognitive activations the amplitude of which is lower. We have studied an activation paradigm such as the Grober and Bruschke test which implies the long term explicit memory. It comprises a visual presentation of words followed by their indexed recall. By using a two-day protocol, 2 SPECTs were achieved in 4 healthy right-handed voluntaries as follows: one of activation (A) and one of control (B). The fifth subject benefited by a SPECT B and of an MRI. The injection for the examination A has been done during the indexed recall stage and for the examination B at the moment when the patient repeated several times the same 3 words. The SPECT data were collected 1 hour after the injection of 370 MBq of ECD making use of a 3-head camera equipped with UHR fan collimators and ending by a LMH on the reconstructed images of 8 mm. The MRI has been achieved by means of a Signa 1.5 Tesla magnet. The SPECT A and B of the subjects 1 to 4 were matched elastically to that of the subject 5 and that of the subject 5 was rigidly matched on its MRI. In this way the individual activation cards of the 4 subjects could be averaged and superimposed on the MRI of the 5. subject. One observes an internal temporal activation (maximal activation of left tonsil, +25% and right uncus, +23%) and a right cingulum activation (maximal activation, +25%), in agreement with the neuro-physiological data. The elastic matching makes possible the inter-subject averaging, what increases the signal-to-noise ratio of activation. The inter-modality rigid matching facilitates the anatomical localisation of the activation site. With these adapted tools, the cognitive activation is thus possible by SPECT and opens perspectives for early diagnosis of neurological troubles, namely of Alzheimer's disease

  19. Metabolic imaging using SPECT

    International Nuclear Information System (INIS)

    Taki, Junichi; Matsunari, Ichiro

    2007-01-01

    In normal condition, the heart obtains more than two-thirds of its energy from the oxidative metabolism of long chain fatty acids, although a wide variety of substrates such as glucose, lactate, ketone bodies and amino acids are also utilised. In ischaemic myocardium, on the other hand, oxidative metabolism of free fatty acid is suppressed and anaerobic glucose metabolism plays a major role in residual oxidative metabolism. Therefore, metabolic imaging can be an important technique for the assessment of various cardiac diseases and conditions. In SPECT, several iodinated fatty acid traces have been introduced and studied. Of these, 123 I-labelled 15-(p-iodophenyl)3-R, S-methylpentadecanoic acid (BMIPP) has been the most commonly used tracer in clinical studies, especially in some of the European countries and Japan. In this review article, several fatty acid tracers for SPECT are characterised, and the mechanism of uptake and clinical utility of BMIPP are discussed in detail. (orig.)

  20. Diagnoses behind patients with hard-to-classify tremor and normal DaT-SPECT: A clinical follow up study

    OpenAIRE

    Manuel eMenéndez-González; Manuel eMenéndez-González; Manuel eMenéndez-González; Francisco eTavares; Nahla eZeidan; José M Salas-Pacheco; Oscar eArias-Carrión

    2014-01-01

    The [123I]ioflupane - a dopamine transporter radioligand - SPECT (DaT-SPECT) has proven to be useful in the differential diagnosis of tremor. Here, we investigate the diagnoses behind patients with hard-to-classify tremor and normal DaT-SPECT. Therefore, 30 patients with tremor and normal DaT-SPECT were followed up for 2 years. In 18 cases we were able to make a diagnosis. The residual 12 patients underwent a second DaT-SPECT, were then followed for additional 12 months and thereafter the dia...

  1. Feasibility study on BNCT-SPECT using a CdTe detector

    International Nuclear Information System (INIS)

    Murata, Isao; Mukai, Taiki; Ito, Masao; Miyamaru, Hiroyuki; Yoshida, Shigeo

    2011-01-01

    There is no doubt that boron neutron capture therapy (BNCT) is a promising cancer therapy in the near future. At present, one of the severest problems to solve is monitoring of the treatment effect during neutron irradiation. It is known to be difficult in real time. So far, activation foils, small detectors and so on were used to measure the thermal neutron fluence in a certain place of the tumor. The dose distribution is thus estimated from the measured result and prediction with a transport code. In the present study, 478 keV gamma-rays emitted from the excited state of 7 Li produced by 10 B(n,α) 7 Li reaction are directly measured to realize real time monitoring of the treatment effect of BNCT. In this paper, the result of the feasibility study carried out using a Monte Carlo transport code is summarized. We used CdTe detectors with a quite narrow collimator to obtain a BNCT image keeping good spatial resolution. The intensity of capture gamma-rays of 2223 keV produced by 1 H(n,γ) 2 H reaction is very much higher than that of 478 keV. We thus adjusted the detector efficiency by selecting an appropriate thickness so as to optimize the efficiency ratio between 478 and 2223 keV. From the result of the detector response calculation, in case of 20 mm thick CdTe detector with the collimator of 2 mm in diameter, sufficient net count of ∼1000 for 478 keV in 30 min. was realized. It means an efficient and high-resolution BNCT-SPECT image could be obtained. (author)

  2. Regional cerebral blood flow studies with single photon emission computed tomography (SPECT); Clinical experiences, possibilities. Regionalis agyi veratfolyas vizsgalata egyfotonos emissios computer tomographiaval (SPECT); Klinikai tapasztalatok, lehetoesegek

    Energy Technology Data Exchange (ETDEWEB)

    Pavics, Laszlo; Csernay, Laszlo; Doczi, Tamas; Lang, Jenoe; Blaho, Gabor; Janka, Zoltan; Bodosi, Mihaly [Szegedi Orvostudomanyi Egyetem, Szeged (Hungary)

    1990-01-07

    Clinical experiences based on regional cerebral blood flow investigations with {sup 99m}Tc hexamethylpropyleneamin-oxime (HMPAO) SPECT in 164 patients are reported. The pharmacokinetics of the {sup 99m}Tc HMPAO are summarized, and the important indications of the investigations are interpreted in case reports (stroke, surgical solution of intracavernous aneurysm, Alzheimer and multiinfarct types of dementia). The literature data suggest that the diagnostic possibilities with this method are advantageous, even in other diseases. (author) 36 refs.; 7 figs.

  3. Resistance vs resilience to Alzheimer disease: Clarifying terminology for preclinical studies.

    Science.gov (United States)

    Arenaza-Urquijo, Eider M; Vemuri, Prashanthi

    2018-04-10

    Preventing or delaying Alzheimer disease (AD) through lifestyle interventions will come from a better understanding of the mechanistic underpinnings of (1) why a significant proportion of elderly remain cognitively normal with AD pathologies (ADP), i.e., amyloid or tau; and (2) why some elderly individuals do not have significant ADP. In the last decades, concepts such as brain reserve, cognitive reserve, and more recently brain maintenance have been proposed along with more general notions such as (neuro)protection and compensation. It is currently unclear how to effectively apply these concepts in the new field of preclinical AD specifically separating the 2 distinct mechanisms of coping with pathology vs avoiding pathology. We propose a simplistic conceptual framework that builds on existing concepts using the nomenclature of resistance in the context of avoiding pathology, i.e., remaining cognitively normal without significant ADP, and resilience in the context of coping with pathology, i.e., remaining cognitively normal despite significant ADP. In the context of preclinical AD studies, we (1) define these concepts and provide recommendations (and common scenarios) for their use; (2) discuss how to employ this terminology in the context of investigating mechanisms and factors; (3) highlight the complementarity and clarity they provide to existing concepts; and (4) discuss different study designs and methodologies. The application of the proposed framework for framing hypotheses, study design, and interpretation of results and mechanisms can provide a consistent framework and nomenclature for researchers to reach consensus on identifying factors that may prevent ADP or delay the onset of cognitive impairment. © 2018 American Academy of Neurology.

  4. Preclinical Cancer Chemoprevention Studies Using Animal Model of Inflammation-Associated Colorectal Carcinogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Takuji [Cytopatholgy Division, Tohkai Cytopathology Institute, Cancer Research and Prevention (TCI-CaRP), 5-1-2 Minami-uzura, Gifu 500-8285 (Japan); Department of Tumor Pathology, Gifu University Graduate School of Medicine, 1-1 Yanagido, Gifu 501-1194 (Japan)

    2012-07-16

    Inflammation is involved in all stages of carcinogenesis. Inflammatory bowel disease, such as ulcerative colitis and Crohn’s disease is a longstanding inflammatory disease of intestine with increased risk for colorectal cancer (CRC). Several molecular events involved in chronic inflammatory process are reported to contribute to multi-step carcinogenesis of CRC in the inflamed colon. They include over-production of free radicals, reactive oxygen and nitrogen species, up-regulation of inflammatory enzymes in arachidonic acid biosynthesis pathway, up-regulation of certain cytokines, and intestinal immune system dysfunction. In this article, firstly I briefly introduce our experimental animal models where colorectal neoplasms rapidly develop in the inflamed colorectum. Secondary, data on preclinical cancer chemoprevention studies of inflammation-associated colon carcinogenesis by morin, bezafibrate, and valproic acid, using this novel inflammation-related colorectal carcinogenesis model is described.

  5. Value of shared preclinical safety studies - The eTOX database.

    Science.gov (United States)

    Briggs, Katharine; Barber, Chris; Cases, Montserrat; Marc, Philippe; Steger-Hartmann, Thomas

    2015-01-01

    A first analysis of a database of shared preclinical safety data for 1214 small molecule drugs and drug candidates extracted from 3970 reports donated by thirteen pharmaceutical companies for the eTOX project (www.etoxproject.eu) is presented. Species, duration of exposure and administration route data were analysed to assess if large enough subsets of homogenous data are available for building in silico predictive models. Prevalence of treatment related effects for the different types of findings recorded were analysed. The eTOX ontology was used to determine the most common treatment-related clinical chemistry and histopathology findings reported in the database. The data were then mined to evaluate sensitivity of established in vivo biomarkers for liver toxicity risk assessment. The value of the database to inform other drug development projects during early drug development is illustrated by a case study.

  6. Preclinical Studies of Chemotherapy Using Histone Deacetylase Inhibitors in Endometrial Cancer

    Directory of Open Access Journals (Sweden)

    Noriyuki Takai

    2010-01-01

    Full Text Available Because epigenetic alterations are believed to be involved in the repression of tumor suppressor genes and promotion of tumorigenesis in endometrial cancers, novel compounds endowed with a histone deacetylase (HDAC inhibitory activity are an attractive therapeutic approach. In this review, we discuss the biologic and therapeutic effects of HDAC inhibitors (HDACIs in treating endometrial cancer. HDACIs were able to mediate inhibition of cell growth, cell cycle arrest, apoptosis, and the expression of genes related to the malignant phenotype in a variety of endometrial cancer cell lines. Furthermore, HDACIs were able to induce the accumulation of acetylated histones in the chromatin of the p21WAF1 gene in human endometrial carcinoma cells. In xenograft models, some HDACIs have demonstrated antitumor activity with only few side effects. In this review, we discuss the biologic and therapeutic effects of HDACIs in treating endometrial cancer, with a special focus on preclinical studies.

  7. Preclinical animal acute toxicity studies of new developed MRI contrast agent based on gadolinium

    Science.gov (United States)

    Nam, I. F.; Zhuk, V. V.

    2015-04-01

    Acute toxicity test of new developed MRI contrast agent based on disodium salt of gadopentetic acid complex were carried out on Mus musculus and Sprague Dawley rats according to guidelines of preclinical studies [1]. Groups of six animals each were selected for experiment. Death and clinical symptoms of animals were recorded during 14 days. As a result the maximum tolerated dose (MTD) for female mice is 2.8 mM/kg of body weight, male mice - 1.4 mM/kg, female rats - 2.8 mM/kg, male rats - 5.6 mM/kg of body weight. No Observed Adverse Effect Dose (NOAEL) for female mice is 1.4 mM/kg, male mice - 0.7 mM/kg, male and female rats - 0.7 mM/kg. According to experimental data new developed MRI contrast agent based on Gd-DTPA complex is low-toxic.

  8. Collimator and energy window optimization for 90Y bremsstrahlung SPECT imaging: A SIMIND Monte Carlo study

    International Nuclear Information System (INIS)

    Roshan, Hoda Rezaei; Mahmoudian, Babak; Gharepapagh, Esmaeil; Azarm, Ahmadreza; Pirayesh Islamian, Jalil

    2016-01-01

    Treatment efficacy of radioembolization using Yttrium-90 ( 90 Y) microspheres is assessed by the 90 Y bremsstrahlung single photon emission computed tomography (SPECT) imaging following radioembolization. The radioisotopic image has the potential of providing reliable activity map of 90 Y microspheres distribution. One of the main reasons of the poor image quality in 90 Y bremsstrahlung SPECT imaging is the continuous and broad energy spectrum of the related bremsstrahlung photons. Furthermore, collimator geometry plays an impressive role in the spatial resolution, sensitivity and image contrast. Due to the relatively poor quality of the 90 Y bremsstrahlung SPECT images, we intend to optimize the medium-energy (ME) parallel-hole collimator and energy window. The Siemens e.cam gamma camera equipped with a ME collimator and a voxelized phantom was simulated by the SImulating Medical Imaging Nuclear Detectors (SIMIND) program. We used the SIMIND Monte Carlo program to generate the 90 Y bremsstrahlung SPECT projection of the digital Jaszczak phantom. The phantom consist of the six hot spheres ranging from 9.5 to 31.8 mm in diameter, which are used to evaluate the image contrast. In order to assess the effect of the energy window on the image contrast, three energy windows ranging from 60 to 160 KeV, 160 to 400 KeV, and 60 to 400 KeV were set on a 90 Y bremsstrahlung spectrum. As well, the effect of the hole diameter of a ME collimator on the image contrast and bremsstrahlung spectrum were investigated. For the fixed collimator and septa thickness values (3.28 cm and 1.14 mm, respectively), a hole diameter range (2.35–3.3 mm) was chosen based on the appropriate balance between the spatial resolution and sensitivity. The optimal energy window for 90 Y bremsstrahlung SPECT imaging was extended energy window from 60 to 400 KeV. Besides, The optimal value of the hole diameter of ME collimator was obtained 3.3 mm. Geometry of the ME parallel-hole collimator and energy

  9. Design of common software for quality control of SPECT

    International Nuclear Information System (INIS)

    Li Xiaohua; Gao Ruzhen; Chen Shengzu

    1993-01-01

    The goal of this study is to design a common testing system for SPECT quality control according to NEMA standard. Using the system, the performances of different types of SPECT can be tested, so that the acceptance testing, performance comparing and routine quality control for SPECT can be normalized. The system was based on IBM PC series of microcomputer. Testing data are acquired from various types of SPECT, then transferred into IBM PC through interface and tested with an unique testing program. Two parts were included: interface and SPECT testing program. It emphatically studied the managing program of RS232 interface, designing skills and the mathematic patterns of SPECT testing program. The system which was composed of 11 subroutines can be used to measure the performances for both gamma camera and SPECT. The system was tested on OMEGA 500/MCS 560 SPECT and the results showed that it is effective, accurate and easy to use

  10. Usefulness of rate of increase in SPECT counts in one-day method of N-isopropyl-4-iodoamphetamine [123I] SPECT studies at rest and after acetazolamide challenge using a method for estimating time-dependent distribution at rest

    International Nuclear Information System (INIS)

    Kawamura, Yoshifumi; Ashizaki, Michio; Saida, Shoko; Sugimoto, Hideharu

    2008-01-01

    When N-isopropyl-4-iodoamphetamine ( 123 I-IMP) single-photon emission computed tomography (SPECT) studies at rest and after acetazolamide (ACZ) challenge are conducted in a day, the time-dependent change in IMP in the brain at rest should be estimated accurately. We devised the method and investigated whether our one-day method for measuring the rate of increase in SPECT counts allowed reduction in the acquisition time. Sequential, 5-min SPECT scans were performed. We estimated the time-dependent change in the brain using the change in slopes of two linear equations derived from the first three SPECT counts. For the one-day method, ACZ was administered 15 min or 20 min after IMP administration. The second IMP was administered 10 min after ACZ administration. Time-dependent changes in the brain were classified into 13 patterns when estimation was started at 5 min after IMP administration and 6 patterns when estimation was started at 10 min, and fitting coefficients were determined. The correlation between actual measurements at 37.5 min and estimates was high with a correlation coefficient of 0.99 or greater. Rates of increase obtained from 20-min data were highly correlated with those obtained from 15-min or 10-min data (r=0.97 or greater). In patients with unilateral cerebrovascular disease, the rate of increase on the unaffected side was 44.4±10.9% when ACZ was administered 15 min later and 48.0±16.0% when ACZ was administered 20 min later, and the rates of increase with different timings of administration were not significantly different. The examination time may be reduced from 50 min to 45 min or 40 min as needed. The rate of increase was not influenced by the time frame for determination or the timing of ACZ administration. These findings suggest that our estimation method is accurate and versatile. (author)

  11. Technetium-99m HM-PAO-SPECT study of regional cerebral perfusion in early Alzheimer's disease

    International Nuclear Information System (INIS)

    Perani, D.; Di Piero, V.; Vallar, G.

    1988-01-01

    Regional cerebral perfusion was evaluated by single photon emission computed tomography (SPECT) using technetium-99m hexamethylpropyleneamine oxime ([/sup 99m/Tc]HM-PAO) in sixteen patients with Alzheimer's disease (AD) in early clinical phase and in 16 healthy elderly controls. In all patients transmission computed tomography (TCT) and/or magnetic resonance imaging (MRI) did not show focal brain abnormalities. Relative to normal subjects, AD patients showed significant reductions in cortical/cerebellar activity ratio: cortical perfusion was globally depressed with the largest reductions in frontal and posterior temporo-parietal cortices. Asymmetries of relative perfusion between cerebral hemispheres were also demonstrated when language was affected or visuospatial functions were unevenly impaired. In patients with early AD, SPECT provides functional information to be compared with clinical and psychometric data

  12. A clinical study in elderly patients with Parkinson's disease using MRI and SPECT; Parkinson's disease and the lacunar state

    Energy Technology Data Exchange (ETDEWEB)

    Umahara, Takahiko; Iwamoto, Toshihiko; Takasaki, Masaru; Katsunuma, Hideyo [Tokyo Medical Coll. (Japan)

    1991-11-01

    Parkinson's disease (PD) is often associated with dementia in elderly patients, and sometimes PD coexists with senile dementia of the Alzheimer type (SDAT) or cerebrovascular disease (CVD) in the elderly. However, since there are few previous clinical studies on the coincidence of, or relationship between PD and CVD, the authors evaluated these aspects in 34 elderly patients with PD using MRI and SPECT. All the patients were over 70 years old. The diagnosis of PD was based on the presence of three symptons (resting tremor, cogwheel rigidity and bradikinesia) which are characteristic of PD, and the effectiveness of L-DOPA therapy. We therefore believe that patients with vascular Parkinsonism were excluded from our study. In 34 cases, 24 (71%) had MRI evidence of CVD (mainly the lacunar state). In the 10 cases who had no CVD, 2 (20%) had severe dementia and the decrease of regional cerebral blood flow (rCBF) in the temporal and parietal lobes bilaterally correlated with the SPECT findings commonly found in SDAT. A comparison of the rCBF and the results of Hasegawa's dementia score (HDS) (verbal intelligence score) was made between the patients with PD associated with CVD and the patients with PD who had no CVD and no SPECT findings which correlated with SDAT. The rCBF in the frontal lobes and the results of the HDS of the former group were significantly lower than those of the latter. As mentioned above, elderly patients with PD often had CVD, leading to dementia. We also pointed out the difficulty in making a differential diagnosis between PD with CVD and vascular Parkinsonism, and the necessity of whether or not the concept of 'mixed type Parkinsonism' should be considered. (author).

  13. 99mTc-HMPAO SPECT thalamic blood flow study in migraine

    International Nuclear Information System (INIS)

    Zhang Zhijian; Steiner, T.J.

    1995-01-01

    The changes of blood flow in the thalamic of migraineurs by 99m Tc-HMPAO SPECT imaging are investigated. 60 cases with migraine were performed by Novo 810 high-resolution SPECT 30 minutes after injection of 99m Tc-HMPAO. The quantitative analysis of SPECT data was based on the irregular ROI% uptake normalized to total slice method. There were significantly increased mean % uptake values in migraine with aura (259.1 +-17.1), and more significantly in those who experienced hemisensory symptoms and hemiparesis during aura (263.8 +- 17.2), compared to that of migraine without aura (249.1 +- 14.9), but there were not statistically significant difference between migraine with only visual disturbance during aura (255.1 +- 16.4) and without aura. The possible explanations for the increased mean % uptake values in migraineurs who experienced hemisensory symptoms and hemiparesis during aura are: (1) the reactive postischemic hyperemia. (2) excepting thalamus, the regional blood flow was decreased. (3) the secondary phenomenon to the various neurogenic and chemical stimuli

  14. The study of low level laser irradiation therapy on brain infarction with SPECT

    Institute of Scientific and Technical Information of China (English)

    Xiao Xuechang; Jia Shaowei; Zleng Xiyuan

    2000-01-01

    Objective: Effect of rCBF and brain function on ILIB treating brain infarction will be investigated by SPECT brain perfusion imaging. Method: 3 1 patients with brain infarction, 17 patients were treated by ILIB on standard pharmaceutial treatment. SPECT brain perfusion imaging was performed before and after ILIB therapy with comparison of oneself. They were quantified with BFCR% model effect during ILIB in 14 patients were observed. Result: ILIB 30 rnme SPECT showed the improvement of rCBF and cerebral function in 14 patients with brain infarction, and in 17 patients locus were prominence than mirror regions att er ILIB therapy, both are higher singnitficant difference ( t=4.4052, P<0.0001 ), but mirror regions were not singnificant difference before and after ILIB (t=1.6995, P>0.05). BFCR% quantitative results of locus were higher mirror regions, and higher singnificant difference (t=4.5278 p<0.0001 )。 Conclusion: ILIB can improve the rCBF and cerebral function of patients with brain infarction, and provoke function of brain cells. Some new evidence was provided for ILIB treatment of cerebral ischemia

  15. The study of brain dopamine transporter 99Tcm-TRODAT-1 SPECT imaging

    International Nuclear Information System (INIS)

    Yang Jian; Su Min; Liu Xiuqian; Liang Weijuan; Zhao Bin; Xu Zhien

    2006-01-01

    Objective: To investigate the distribution character of 99 Tc m -2β-[N, N'-bis (2-mercaptoethyl) ethylenediamino] methyl, 3β-(4-chlorophenyl) tropane (TRODAT-1) in basal ganglia and the diagnostic value of SPECT imaging in Parkinson' s disease (PD). Methods: 99 Tc m -TRODAT-l SPECT imaging was performed in 30 PD patients and 16 age-matched healthy volunteers. Two semiquantitative analysis methods were used: (1)Striatum(ST)/cerebellum (CB) uptake ratio (ST/CB) was calculated by regions of interest (ROIs) in three transverse and sagittal slice. (2) ROIs were drawn manually on six subregions of both basal ganglia and also CB and occipital region(OC) as reference, and the corresponding uptake ratio of ROI/(OC + CB/2) was calculated. Results: The ST/CB in transverse and sagittal slice for the left and right were 1.55 ± 0.15, 1.58 ± 0.14 and 1.62 ± 0.17, 1.69 ± 0.16 respectively in healthy volunteers. The ST/CB and ROI/(OC + CB/2) in the basal ganglia of PD patients were significantly less than those of healthy volunteers (P 99 Tc m -TRODAT-1 SPECT imaging is an effective method in diagnosis of PD. (authors)

  16. Feasibility study of segmented-parallel-hole collimator for stationary cardiac SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Yanfei [Utah Univ., Salt Lake City, UT (United States). Center for Advanced Imaging Research (UCAIR); Utah Univ., Salt Lake City, UT (United States). Dept. of Bioengineering; Zeng, Gengsheng L. [Utah Univ., Salt Lake City, UT (United States). Center for Advanced Imaging Research (UCAIR)

    2011-07-01

    The goal of this research is to propose a stationary cardiac SPECT system using the segmented parallel-beam collimator and to perform some computer simulations to test the feasibility. A stationary system has a benefit of acquiring temporally consistent projections. The most challenging issue in building a stationary system is to provide sufficient projection view-angles. A 2-detector, multi-segment collimator system with 14 view-angles over 180 in the transaxial direction and 3 view-angles in the axial directions was designed, where the two detectors are configured 90 apart in an L-shape. We applied the parallel-beam imaging geometry and used segmented parallel-hole collimator to acquire SPECT data. To improve the system condition due to data truncation, we measured more rays within the field-of-view (FOV) of the detector by using a relatively small detector bin-size. In image reconstruction, we used the maximum-likelihood expectation-maximization (ML-EM) algorithm. The criterion for evaluating the system is the summed pixel-to-pixel distance that measures the discrepancy between the 3D gold-standard image and the reconstructed 3D region of interest (ROI) with truncated data. Effects of limited number of view-angles, data truncation, varying body habitus, attenuation, and noise were considered in the system design. As a result, our segmented-parallel-beam stationary cardiac SPECT system is able to acquire sufficient data for cardiac imaging and has a high sensitivity gain. (orig.)

  17. Influence of attenuation correction and reconstruction techniques on the detection of hypoperfused lesions in brain SPECT studies

    International Nuclear Information System (INIS)

    Ghoorun, S.; Groenewald, W.A.; Baete, K.; Nuyts, J.; Dupont, P.

    2004-01-01

    Full text: Aim: To study the influence of attenuation correction and the reconstruction technique on the detection of hypoperfused lesions in brain SPECT imaging, Material and Methods: A simulation experiment was used in which the effects of attenuation and reconstruction were decoupled, A high resolution SPECT phantom was constructed using the BrainWeb database, In this phantom, activity values were assigned to grey and white matter (ratio 4:1) and scaled to obtain counts of the same magnitude as in clinical practice, The true attenuation map was generated by assigning attenuation coefficients to each tissue class (grey and white matter, cerebral spinal fluid, skull, soft and fatty tissue and air) to create a non-uniform attenuation map, The uniform attenuation map was calculated using an attenuation coefficient of 0.15 cm-1, Hypoperfused lesions of varying intensities and sizes were added. The phantom was then projected as typical SPECT projection data, taking into account attenuation and collimator blurring with the addition of Poisson noise, The projection data was reconstructed using four different methods of reconstruction: (1) filtered backprojection (FBP) with the uniform attenuation map; (2) FBP using the true attenuation map; (3) ordered subset expectation maximization (OSEM) (equivalent to 423 iterations) with a uniform attenuation map; and (4) OSEM with a true attenuation map. Different Gaussian postsmooth kernels were applied to the reconstructed images. Results: The analysis of the reconstructed data was performed using figures of merit such as signal to noise ratio (SNR), bias and variance. The results illustrated that uniform attenuation correction offered slight deterioration (less than 2%) with regard to SNR when compared to the ideal attenuation map. which in reality is not known. The iterative techniques produced superior signal to noise ratios (increase of 5 - 20 % depending on the lesion and the postsmooth) in comparison to the FBP methods

  18. A study of cerebral circulation in elderly patients with dementia using sup 123 I-IMP SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Arai, Hisayuki [Tokyo Medical Coll. (Japan)

    1991-03-01

    In order to elucidate the pathogenesis of senile dementia of Alzheimer type (SDAT) and multi-infarct dementia (MID), 18 age-matched controls, 22 SDAT cases, 10 MID cases, and 15 multiple infarction without dementia (MI) cases, totaling 65 cases, were enrolled into a study of cerebral blood flow using single photon emission CT (SPECT) with N-isopropyl-p-({sup 123}I)iodoamphetamine (IMP). The diagnosis of dementia was made based on the clinical history, findings of brain CT, MRI, and Hachinski's ischemic score. Lateral asymmetric perfusion was evaluated by using the asymmetry index (AI). Quantitative cerebral blood flow was analyzed by using the venous blood sampling method with IMP SPECT. Cerebral infarction, ischemic changes, and brain atrophy were diagnosed by CT and MRI. mCBF values were significantly lower in SDAT and MID than in those of controls, while rCBF values were lowest at the frontal lobes in MID and at the parietal lobes in SDAT. Hasegawa's dementia score was correlated with the rCBF at the frontal lobes in MID. In MID, there was a greater number of infarction, and atrophic changes were significantly remarkable, while the rCBF values were significantly lower at the frontal lobes compared to the MI group. Multi-variate analysis suggested that among the factors contributing to MID, brain atrophy was most relevant to dementia. In SDAT, rCBF values showed the most lateral asymmetry at the parietal lobes, the least, at the occipital lobes. The lateral asymmetry of the cerebral blood flow at the parietal lobes showed an association with clinical symptoms. There was a negative coefficiency between the cerebellum and the cerebral hemisphere in the evaluation of lateral asymmetry. These results suggest that rCBF estimation by IMP SPECT is useful in the differential diagnosis between MID and SDAT, and may also contribute to the classification of these two diseases. (author).

  19. Evaluation of the quality of picture in studies of sect brain acquired with various collimators; Evaluacion de la calidad de imagen en estudios de spect cerebral adquiridos con distintos colimadores

    Energy Technology Data Exchange (ETDEWEB)

    Moran Velasco, V.; Prieto Azcarete, E.; Barbes Fernandez, B.; Sancho rodriguez, L.; Ribelles Segura, M. J.; Richter echevarria, J. A.; Arbizu Lostao, J.; Marti-Climent, J. M.

    2015-07-01

    On the practice clinic , the performance of the systems SPECT depends on in large measurement of the quality of image. The goal of East study was evaluate how affect the parameters of reconstruction of studies SPECT of perfusion brain acquired with a collimator of holes parallel (LEHR) and other of holes in fan (Fan-Beam). (Author)

  20. Preclinical pharmacological study on I-ADAM as a serotonin transporter ligand

    International Nuclear Information System (INIS)

    Wu Chunying; Lu Chunxiong; Jiang Quanfu; Zou Meifen; Chen Zhengping; Wang Songpei; Li Xiaomin; Zhang Tongxing; Zhu Junqing; Lin Xiangtong

    2004-01-01

    Objective: To evaluate the new ligand: I-2-( (22( (dimethylamino) methyl) phenyl) thio)-5- iodophenylamine (ADAM) as a serotonin imaging agent. Methods: Biological evaluations were performed in rats and mice. Results: Biodistribution studies in rats showed that the initial uptake of 131 I-ADAM in the brain was high (1.087%ID/organ at 2 min postinjection), and consistently displayed the highest binding (between 60-240 min postinjection) in hypothalamus, a region with the highest density of serotonin transporter (SERT). The specific binding [(TPCB)-1] of 131 I-ADAM in hypothalamus was 2.94, 3.03 and 3.09 at 60, 120 and 240 min postinjection, respectively. The (TPCB)-1 was significantly blocked by pretreatment with Paroxetine, which is known as a serotonin site reuptake inhibitor, while another nonselective competing drug, Ketanserin, showed no blocking effect. The rat brain autoradiography and analysis showed that there was high 131 I-ADAM uptake in hypothalamus, the ratio of hypothalamus/cerebellum was significantly reduced from 7.94 ± 0.39 to 1.30 ± 0.56 by pretreatment with Paroxetine at 60 min postinjection. Blood clearance kinetics was studied in rats, and the initial half-life of 13.79 min and late half-life of 357.14 min were obtained. The kinetic equation was: C=3.6147·e -0.0725t + 1.0413 e -0.0028t . The thyroid uptake was 0.009 and 1.421% ID/organ at 2 min and 120 min postinjection, respectively, suggesting that in vivo deiodination maybe the major route of metabolism. Toxicity trial showed that the dose per kilogram administered to mice was 1000 times greater than that to human beings, assuming a body-weight of 50 kg. Conclusion: These data suggest that 131 I-ADAM may be useful for SPECT imaging of SERT binding sits in the brain. (authors)

  1. Tissue Engineering of the Urethra: A Systematic Review and Meta-analysis of Preclinical and Clinical Studies

    NARCIS (Netherlands)

    Versteegden, L.R.; Jonge, P. de; Hout, J. in't; Kuppevelt, T.H. van; Oosterwijk, E.; Feitz, W.F.J.; Vries, R.B.M. de; Daamen, W.F.

    2017-01-01

    CONTEXT: Urethra repair by tissue engineering has been extensively studied in laboratory animals and patients, but is not routinely used in clinical practice. OBJECTIVE: To systematically investigate preclinical and clinical evidence of the efficacy of tissue engineering for urethra repair in order

  2. A Giant Hepatic Hemangioma Complicated by Kasabach-Merritt Syndrome: Findings of Tc-99m RBC Scintigraphy and SPECT Including a Total Body Blood Pool Imaging Study

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Myung Hee; Jeong, Hwan Jeong; Lim, Seok Tae; Kim, Dong Wook; Yim, Chang Yeol [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2009-02-15

    Kasabach-Merritt syndrome (KMS) consists of thrombocytopenia, microangiopathic hemolytic anemia, and localized consumption coagulopathy that develops within vascular hemangioma. This syndrome may also be associated with occult hemangiomas located at various sites. Tc-99m RBC scintigraphy and SPECT have proven to be reliable for confirming or excluding hemangioma. Total body blood pool imaging study during the scintigraphy also provides a means of screening for occult lesions. The authors report the case of a 29-year-old man who presented with a giant hepatic hemangioma complicated by KMS, and underwent Tc-99m RBC scintigraphy and SPECT including a total body blood pool imaging study.

  3. Regional cerebral blood flow and metabolism in patients with transient global amnesia. A study using SPECT and {sup 1}H-MRS

    Energy Technology Data Exchange (ETDEWEB)

    Ishihara, Tetsuya; Hirata, Koichi; Tatsumoto, Muneto; Yamazaki, Kaoru [Dokkyo Univ., Tochigi (Japan). School of Medicine; Sato, Toshihiko

    1997-06-01

    In 13 patients with transient global amnesia (TGA), we studied the clinical course and changes over time by means of imaging techniques such as SPECT. MRI, and proton MR spectroscopy ({sup 1}H-MRS). In the case of SPECT, a cerebral blood flow decrease at the time center of the temporal lobe persisted at least for more than one month. In many patients, no abnormal signs were found on MRI. Despite the presence of intracranial impairment of energy metabolism, no evidence of cerebral ischemia was obtained using {sup 1}H-MRS at the acute and subacute stages. There were thus discrepancies between the symptoms and the findings of SPECT as well as the findings of {sup 1}H-MRS. These data suggest that TGA may not necessarily be caused by cerebra1 ischemia. (author)

  4. Regional cerebral blood flow and metabolism in patients with transient global amnesia. A study using SPECT and 1H-MRS

    International Nuclear Information System (INIS)

    Ishihara, Tetsuya; Hirata, Koichi; Tatsumoto, Muneto; Yamazaki, Kaoru; Sato, Toshihiko.

    1997-01-01

    In 13 patients with transient global amnesia (TGA), we studied the clinical course and changes over time by means of imaging techniques such as SPECT. MRI, and proton MR spectroscopy ( 1 H-MRS). In the case of SPECT, a cerebral blood flow decrease at the time center of the temporal lobe persisted at least for more than one month. In many patients, no abnormal signs were found on MRI. Despite the presence of intracranial impairment of energy metabolism, no evidence of cerebral ischemia was obtained using 1 H-MRS at the acute and subacute stages. There were thus discrepancies between the symptoms and the findings of SPECT as well as the findings of 1 H-MRS. These data suggest that TGA may not necessarily be caused by cerebra1 ischemia. (author)

  5. Automatic construction of 3D-ASM intensity models by simulating image acquisition: application to myocardial gated SPECT studies.

    Science.gov (United States)

    Tobon-Gomez, Catalina; Butakoff, Constantine; Aguade, Santiago; Sukno, Federico; Moragas, Gloria; Frangi, Alejandro F

    2008-11-01

    Active shape models bear a great promise for model-based medical image analysis. Their practical use, though, is undermined due to the need to train such models on large image databases. Automatic building of point distribution models (PDMs) has been successfully addressed and a number of autolandmarking techniques are currently available. However, the need for strategies to automatically build intensity models around each landmark has been largely overlooked in the literature. This work demonstrates the potential of creating intensity models automatically by simulating image generation. We show that it is possible to reuse a 3D PDM built from computed tomography (CT) to segment gated single photon emission computed tomography (gSPECT) studies. Training is performed on a realistic virtual population where image acquisition and formation have been modeled using the SIMIND Monte Carlo simulator and ASPIRE image reconstruction software, respectively. The dataset comprised 208 digital phantoms (4D-NCAT) and 20 clinical studies. The evaluation is accomplished by comparing point-to-surface and volume errors against a proper gold standard. Results show that gSPECT studies can be successfully segmented by models trained under this scheme with subvoxel accuracy. The accuracy in estimated LV function parameters, such as end diastolic volume, end systolic volume, and ejection fraction, ranged from 90.0% to 94.5% for the virtual population and from 87.0% to 89.5% for the clinical population.

  6. Prediction of functional recovery after revascularization using quantitative gated myocardial perfusion SPECT: a multi-center cohort study in Japan

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Tamaki, Nagara; Kuwabara, Yoichi; Kawano, Masaya; Matsunari, Ichiro; Taki, Junichi; Nishimura, Shigeyuki; Yamashina, Akira; Ishida, Yoshio; Tomoike, Hitonobu

    2008-01-01

    Prediction of left ventricular functional recovery is important after myocardial infarction. The impact of quantitative perfusion and motion analyses with gated single-photon emission computed tomography (SPECT) on predictive ability has not been clearly defined in multi-center studies. A total of 252 patients with recent myocardial infarction (n = 74) and old myocardial infarction (n = 175) were registered from 25 institutions. All patients underwent resting gated SPECT using 99m Tc-hexakis-2-methoxy-isobutyl isonitrile (MIBI) and repeated the study after revascularization after an average follow-up period of 132 ± 81 days. Visual and quantitative assessment of perfusion and wall motion were performed in 5,040 segments. Non-gated segmental percent uptake and end-systolic (ES) percent uptake were good predictors of wall motion recovery and significantly differed between improved and non-improved groups (66 ± 17% and 55 ± 18%, p 99m Tc-MIBI uptake provided a useful predictor of wall motion improvement. Application of quantitative approach with non-gated and ES percent uptake enhanced predictive accuracy over visual analysis particularly in a multi-center study. (orig.)

  7. Preliminary Experience with Small Animal SPECT Imaging on Clinical Gamma Cameras

    Directory of Open Access Journals (Sweden)

    P. Aguiar

    2014-01-01

    Full Text Available The traditional lack of techniques suitable for in vivo imaging has induced a great interest in molecular imaging for preclinical research. Nevertheless, its use spreads slowly due to the difficulties in justifying the high cost of the current dedicated preclinical scanners. An alternative for lowering the costs is to repurpose old clinical gamma cameras to be used for preclinical imaging. In this paper we assess the performance of a portable device, that is, working coupled to a single-head clinical gamma camera, and we present our preliminary experience in several small animal applications. Our findings, based on phantom experiments and animal studies, provided an image quality, in terms of contrast-noise trade-off, comparable to dedicated preclinical pinhole-based scanners. We feel that our portable device offers an opportunity for recycling the widespread availability of clinical gamma cameras in nuclear medicine departments to be used in small animal SPECT imaging and we hope that it can contribute to spreading the use of preclinical imaging within institutions on tight budgets.

  8. Cognitive and emotional behavioural changes associated with methylphenidate treatment: a review of preclinical studies.

    Science.gov (United States)

    Britton, Gabrielle B

    2012-02-01

    There is evidence from animal studies that repeated exposure to methylphenidate (MPH), a widely used psychostimulant for the treatment of attention deficit hyperactivity disorder (ADHD), produces behavioural, structural and neurochemical changes that persist long after drug administration has ended. However, the translational utility of much of this work is compromised by the use of drug doses and routes of administration that produce plasma and brain MPH levels that fall outside the clinical range, i.e. experimental parameters more relevant to drug abuse than ADHD. We used PubMed to identify pre-clinical studies that employed repeated MPH administration at low doses in young rodents and examined long-term effects on cognition, emotion, and brain structure and function. A review of this work suggests that repeated MPH treatment during early development can modify a number of cognitive, behavioural and brain processes, but these are reduced when low therapeutic doses are employed. Moreover, MPH sites of action extend beyond those implicated in ADHD. Studies that combined neurobiological and behavioural approaches provide important insights into the mechanisms underlying MPH-produced effects on cognitive and behavioural processes, which may be relevant to MPH therapeutic efficacy. There is an emerging consensus that pharmacological treatment of childhood psychiatric disorders produces persistent neuroadaptations, highlighting the need for studies that assess long-term effects of early developmental pharmacotherapy. In this regard, studies that mimic clinical therapy with rodents are useful experimental approaches for defining the behavioural and neural plasticity associated with stimulant therapy in paediatric populations.

  9. Study on the usefulness of whole body SPECT coronal image, MIP image in {sup 67}Ga scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Seiji [Kurume Univ., Fukuoka (Japan). Hospital; Ishibashi, Masatoshi; Kurata, Seiji; Morita, Seiichirou; Hayabuchi, Naofumi [Kurume Univ., Fukuoka (Japan). School of Medicine; Fukushima, Shigehiro [Kyushu Inst. of Design, Fukuoka (Japan). Graduate School of Auditory and Visual Communication Sciences; Umezaki, Noriyoshi [Daiichi Coll. of Pharmaceutical Sciences, Fukuoka (Japan)

    2002-05-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with {sup 67}Ga-citrate ({sup 67}Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  10. A comparison between the conventional manual ROI method and an automatic algorithm for semiquantitative analysis of SPECT studies

    International Nuclear Information System (INIS)

    Pagan, L; Novi, B; Guidarelli, G; Tranfaglia, C; Galli, S; Lucchi, G; Fagioli, G

    2011-01-01

    In this study, the performance of a free software for automatic segmentation of striatal SPECT brain studies (BasGanV2 - www.aimn.it) and a standard manual Region Of Interest (ROI) method were compared. The anthropomorphic Alderson RSD phantom, filled with solutions at different concentration of 123 I-FP-CIT with Caudate-Putamen to Background ratios between 1 and 8.7 and Caudate to Putamen ratios between 1 and 2, was imaged on a Philips-Irix triple head gamma camera. Images were reconstructed using filtered back-projection and processed with both BasGanV2, that provides normalized striatal uptake values on volumetric anatomical ROIs, and a manual method, based on average counts per voxel in ROIs drawn in a three-slice section. Caudate-Putamen/Background and Caudate/Putamen ratios obtained with the two methods were compared with true experimental ratios. Good correlation was found for each method; BasGanV2, however, has higher R index (BasGan R mean = 0.95, p mean = 0.89, p 123 I-FP-CIT SPECT data with, moreover, the advantage of the availability of a control subject's database.

  11. CCD-camera-based diffuse optical tomography to study ischemic stroke in preclinical rat models

    Science.gov (United States)

    Lin, Zi-Jing; Niu, Haijing; Liu, Yueming; Su, Jianzhong; Liu, Hanli

    2011-02-01

    Stroke, due to ischemia or hemorrhage, is the neurological deficit of cerebrovasculature and is the third leading cause of death in the United States. More than 80 percent of stroke patients are ischemic stroke due to blockage of artery in the brain by thrombosis or arterial embolism. Hence, development of an imaging technique to image or monitor the cerebral ischemia and effect of anti-stoke therapy is more than necessary. Near infrared (NIR) optical tomographic technique has a great potential to be utilized as a non-invasive image tool (due to its low cost and portability) to image the embedded abnormal tissue, such as a dysfunctional area caused by ischemia. Moreover, NIR tomographic techniques have been successively demonstrated in the studies of cerebro-vascular hemodynamics and brain injury. As compared to a fiberbased diffuse optical tomographic system, a CCD-camera-based system is more suitable for pre-clinical animal studies due to its simpler setup and lower cost. In this study, we have utilized the CCD-camera-based technique to image the embedded inclusions based on tissue-phantom experimental data. Then, we are able to obtain good reconstructed images by two recently developed algorithms: (1) depth compensation algorithm (DCA) and (2) globally convergent method (GCM). In this study, we will demonstrate the volumetric tomographic reconstructed results taken from tissuephantom; the latter has a great potential to determine and monitor the effect of anti-stroke therapies.

  12. Review of Preclinical and Clinical Studies of Bone Marrow-Derived Cell Therapies for Intracerebral Hemorrhage

    Directory of Open Access Journals (Sweden)

    Paulo Henrique Rosado-de-Castro

    2016-01-01

    Full Text Available Stroke is the second leading cause of mortality worldwide, causing millions of deaths annually, and is also a major cause of disability-adjusted life years. Hemorrhagic stroke accounts for approximately 10 to 27% of all cases and has a fatality rate of about 50% in the first 30 days, with limited treatment possibilities. In the past two decades, the therapeutic potential of bone marrow-derived cells (particularly mesenchymal stem cells and mononuclear cells has been intensively investigated in preclinical models of different neurological diseases, including models of intracerebral hemorrhage and subarachnoid hemorrhage. More recently, clinical studies, most of them small, unblinded, and nonrandomized, have suggested that the therapy with bone marrow-derived cells is safe and feasible in patients with ischemic or hemorrhagic stroke. This review discusses the available evidence on the use of bone marrow-derived cells to treat hemorrhagic strokes. Distinctive properties of animal studies are analyzed, including study design, cell dose, administration route, therapeutic time window, and possible mechanisms of action. Furthermore, clinical trials are also reviewed and discussed, with the objective of improving future studies in the field.

  13. Learning style preferences: A study of pre-clinical medical students in Barbados

    Science.gov (United States)

    OJEH, NKEMCHO; SOBERS-GRANNUM, NATASHA; GAUR, UMA; UDUPA, ALAYA; MAJUMDER, MD.ANWARUL AZIM

    2017-01-01

    Introduction: Educators need to be aware of different learning styles to effectively tailor instructional strategies and methods to cater to the students’ learning needs and support a conductive learning environment. The VARK [an acronym for visual (V), aural (A), read/write (R) and kinesthetic (K)] instrument is a useful model to assess learning styles. The aim of this study was to use the VARK questionnaire to determine the learning styles of pre-clinical medical students in order to compare the perceived and assessed learning style preferences, assess gender differences in learning style preferences, and determine whether any relationships exists between awareness of learning styles and academic grades, age, gender and learning modality. Methods: The VARK questionnaire was administered to pre-clinical students taking a variety of courses in the first three years of the undergraduate MB BS degree programme at the Faculty of Medical Sciences, The University of the West Indies, Cave Hill Campus, Barbados in 2014. Results: The majority of the students were multimodal learners with no differences observed between males (59.5%) and females (60.0%), with tetramodal being the most common. Read/write (33.8%) followed by kinesthetic (32.5%) were the most common learning style preferences. The sensory modality preference for females was read/write (34.2%) and for males it was kinesthetic (40.5%). Significant differences were observed between the perceived and assessed learning style preferences with a majority of visual and read/write learners correctly matching their perceived to their actual learning styles. Awareness of learning styles was associated with learning modality but not with academic performance, age or gender. Overall, 60.7% of high achievers used multimodal learning compared to 56.9% low achievers. Conclusion: The findings from this study indicated that the VARK tool was useful in gathering information about different learning styles, and might assist

  14. Learning style preferences: A study of pre-clinical medical students in Barbados.

    Science.gov (United States)

    Ojeh, Nkemcho; Sobers-Grannum, Natasha; Gaur, Uma; Udupa, Alaya; Majumder, Md Anwarul Azim

    2017-10-01

    Educators need to be aware of different learning styles to effectively tailor instructional strategies and methods to cater to the students' learning needs and support a conductive learning environment. The VARK [an acronym for visual (V), aural (A), read/write (R) and kinesthetic (K)] instrument is a useful model to assess learning styles. The aim of this study was to use the VARK questionnaire to determine the learning styles of pre-clinical medical students in order to compare the perceived and assessed learning style preferences, assess gender differences in learning style preferences, and determine whether any relationships exists between awareness of learning styles and academic grades, age, gender and learning modality. The VARK questionnaire was administered to pre-clinical students taking a variety of courses in the first three years of the undergraduate MB BS degree programme at the Faculty of Medical Sciences, The University of the West Indies, Cave Hill Campus, Barbados in 2014. The majority of the students were multimodal learners with no differences observed between males (59.5%) and females (60.0%), with tetramodal being the most common. Read/write (33.8%) followed by kinesthetic (32.5%) were the most common learning style preferences. The sensory modality preference for females was read/write (34.2%) and for males it was kinesthetic (40.5%). Significant differences were observed between the perceived and assessed learning style preferences with a majority of visual and read/write learners correctly matching their perceived to their actual learning styles. Awareness of learning styles was associated with learning modality but not with academic performance, age or gender. Overall, 60.7% of high achievers used multimodal learning compared to 56.9% low achievers. The findings from this study indicated that the VARK tool was useful in gathering information about different learning styles, and might assist educators in designing blended teaching

  15. Learning style preferences: A study of Pre-clinical Medical Students in Barbados

    Directory of Open Access Journals (Sweden)

    NKEMCHO OJEH

    2017-10-01

    Full Text Available Introduction: Educators need to be aware of different learning styles to effectively tailor instructional strategies and methods to cater to the students’ learning needs and support a conductive learning environment. The VARK [an acronym for visual (V, aural (A, read/write (R and kinesthetic (K] instrument is a useful model to assess learning styles. The aim of this study was to use the VARK questionnaire to determine the learning styles of pre-clinical medical students in order to compare the perceived and assessed learning style preferences, assess gender differences in learning style preferences, and determine whether any relationships exists between awareness of learning styles and academic grades, age, gender and learning modality. Methods: The VARK questionnaire was administered to preclinical students taking a variety of courses in the first three years of the undergraduate MB BS degree programme at the Faculty of Medical Sciences, The University of the West Indies, Cave Hill Campus, Barbados in 2014. Results: The majority of the students were multimodal learners with no differences observed between males (59.5% and females (60.0%, with tetramodal being the most common. Read/write (33.8% followed by kinesthetic (32.5% were the most common learning style preferences. The sensory modality preference for females was read/write (34.2% and for males it was kinesthetic (40.5%. Significant differences were observed between the perceived and assessed learning style preferences with a majority of visual and read/write learners correctly matching their perceived to their actual learning styles. Awareness of learning styles was associated with learning modality but not with academic performance, age or gender. Overall, 60.7% of high achievers used multimodal learning compared to 56.9% low achievers. Conclusion: The findings from this study indicated that the VARK tool was useful in gathering information about different learning styles, and might

  16. JAK2 inhibitor therapy in myeloproliferative disorders: rationale, preclinical studies and ongoing clinical trials.

    Science.gov (United States)

    Pardanani, A

    2008-01-01

    The recent identification of somatic mutations such as JAK2V617F that deregulate Janus kinase (JAK)-signal transducer and activator of transcription signaling has spurred development of orally bioavailable small-molecule inhibitors that selectively target JAK2 kinase as an approach to pathogenesis-directed therapy of myeloproliferative disorders (MPD). In pre-clinical studies, these compounds inhibit JAK2V617F-mediated cell growth at nanomolar concentrations, and in vivo therapeutic efficacy has been demonstrated in mouse models of JAK2V617F-induced disease. In addition, ex vivo growth of progenitor cells from MPD patients harboring JAK2V617F or MPLW515L/K mutations is also potently inhibited. JAK2 inhibitors currently in clinical trials can be grouped into those designed to primarily target JAK2 kinase (JAK2-selective) and those originally developed for non-MPD indications, but that nevertheless have significant JAK2-inhibitory activity (non-JAK2 selective). This article discusses the rationale for using JAK2 inhibitors for the treatment of MPD, as well as relevant aspects of clinical trial development for these patients. For instance, which group of MPD patients is appropriate for initial Phase I studies? Should JAK2V617F-negative MPD patients be included in the initial studies? What are the likely consequences of 'off-target' JAK3 and wild-type JAK2 inhibition? How should treatment responses be monitored?

  17. Small Molecular TRAIL Inducer ONC201 Induces Death in Lung Cancer Cells: A Preclinical Study.

    Science.gov (United States)

    Feng, Yuan; Zhou, Jihong; Li, Zhanhua; Jiang, Ying; Zhou, Ying

    2016-01-01

    Tumor necrosis factor (TNF)-related apoptosis-inducing ligand (TRAIL) selectively targets cancer cells. The present preclinical study investigated the anti-cancer efficiency of ONC201, a first-in-class small molecule TRAIL inducer, in lung cancer cells. We showed that ONC201 was cytotoxic and anti-proliferative in both established (A549 and H460 lines) and primary human lung cancer cells. It was yet non-cytotoxic to normal lung epithelial cells. Further, ONC201 induced exogenous apoptosis activation in lung cancer cells, which was evidenced by TRAIL/death receptor-5 (DR5) induction and caspase-8 activation. The caspase-8 inhibitor or TRAIL/DR5 siRNA knockdown alleviated ONC201's cytotoxicity against lung cancer cells. Molecularly, ONC201 in-activated Akt-S6K1 and Erk signalings in lung cancer cells, causing Foxo3a nuclear translocation. For the in vivo studies, intraperitoneal injection of ONC201 at well-tolerated doses significantly inhibited xenografted A549 tumor growth in severe combined immunodeficient (SCID) mice. Further, ONC201 administration induced TRAIL/DR5 expression, yet inactivated Akt-S6K1 and Erk in tumor tissues. These results of the study demonstrates the potent anti-lung cancer activity by ONC201.

  18. Small Molecular TRAIL Inducer ONC201 Induces Death in Lung Cancer Cells: A Preclinical Study.

    Directory of Open Access Journals (Sweden)

    Yuan Feng

    Full Text Available Tumor necrosis factor (TNF-related apoptosis-inducing ligand (TRAIL selectively targets cancer cells. The present preclinical study investigated the anti-cancer efficiency of ONC201, a first-in-class small molecule TRAIL inducer, in lung cancer cells. We showed that ONC201 was cytotoxic and anti-proliferative in both established (A549 and H460 lines and primary human lung cancer cells. It was yet non-cytotoxic to normal lung epithelial cells. Further, ONC201 induced exogenous apoptosis activation in lung cancer cells, which was evidenced by TRAIL/death receptor-5 (DR5 induction and caspase-8 activation. The caspase-8 inhibitor or TRAIL/DR5 siRNA knockdown alleviated ONC201's cytotoxicity against lung cancer cells. Molecularly, ONC201 in-activated Akt-S6K1 and Erk signalings in lung cancer cells, causing Foxo3a nuclear translocation. For the in vivo studies, intraperitoneal injection of ONC201 at well-tolerated doses significantly inhibited xenografted A549 tumor growth in severe combined immunodeficient (SCID mice. Further, ONC201 administration induced TRAIL/DR5 expression, yet inactivated Akt-S6K1 and Erk in tumor tissues. These results of the study demonstrates the potent anti-lung cancer activity by ONC201.

  19. SPECT/CT and pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Jann [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); The Faroese National Hospital, Department of Medicine, Torshavn (Faroe Islands); Gutte, Henrik [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Herlev Hospital, Copenhagen University Hospital, Department of Radiology, Copenhagen (Denmark); University of Copenhagen, Cluster for Molecular Imaging, Faculty of Health Sciences, Copenhagen (Denmark)

    2014-05-15

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar technique for diagnosing PE. SPECT has been shown to have fewer indeterminate results and a higher diagnostic value. The latest improvement is the combination of a low-dose CT scan with a V/P SPECT scan in a hybrid tomograph. In a study comparing CTPA, planar scintigraphy and SPECT alone, SPECT/CT had the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume coverage per rotation and faster rotation. Furthermore, the dual energy CT technique is a promising modality that can provide functional imaging in combination with anatomical information. Newer high-end CT scanners and SPECT systems are able to visualize smaller subsegmental emboli. However, consensus is lacking regarding the clinical impact and treatment. In the present review, SPECT and SPECT in combination with low-dose CT, CTPA and dual energy CT are discussed in the context of diagnosing PE. (orig.)

  20. Prospective study of p-[{sup 123}I]iodo-L-phenylalanine and SPECT for the evaluation of newly diagnosed cerebral lesions: specific confirmation of glioma

    Energy Technology Data Exchange (ETDEWEB)

    Hellwig, Dirk; Schaefer, Andrea; Farmakis, Georgios; Grgic, Aleksandar; Kirsch, Carl-Martin [Saarland University Medical Center, Department of Nuclear Medicine, Homburg/Saar (Germany); Ketter, Ralf; Moringlane, Jean R.; Steudel, Wolf-Ingo [Saarland University Medical Center, Department of Neurosurgery, Homburg (Germany); Romeike, Bernd F.M. [Saarland University Medical Center, Institute of Neuropathology, Homburg (Germany); Friedrich-Schiller-University, Department of Neuropathology, Jena (Germany); Samnick, Samuel [Saarland University Medical Center, Department of Nuclear Medicine, Homburg/Saar (Germany); University of Wuerzburg, Department of Nuclear Medicine, Wuerzburg (Germany)

    2010-12-15

    The differentiation between gliomas, metastases and gliotic or inflammatory lesions by imaging techniques remains a challenge. Gliomas frequently exhibit increased uptake of radiolabelled amino acids and are thus amenable to PET or SPECT imaging. Recently, p-[{sup 123}I]iodo-L-phenylalanine (IPA) was validated for the visualization of glioma by SPECT and received orphan drug status. Here we investigated its diagnostic performance for differentiating indeterminate brain lesions. This prospective open study included 67 patients with newly diagnosed brain lesions suspicious for glioma (34 without and 33 with contrast enhancement in the MRI scan). Patients received 250 MBq IPA intravenously after overnight fasting. SPECT images at 30 min and 3 h post-injection were iteratively reconstructed and visually interpreted after image fusion with an MRI brain scan (fluid-attenuated inversion recovery sequence or T1-weighted contrast-enhanced image). Findings were correlated with results of stereotactic or open biopsies or serial imaging. Twenty-seven low-grade (2 WHO I, 25 WHO II) and 24 high-grade gliomas (1 WHO III, 23 WHO IV), 3 metastases originating from lung cancer as well as 13 non-neoplastic lesions were proven. All non-neoplastic lesions and all metastases were negative with IPA SPECT. Forty gliomas were true-positive (TP) and 11 false-negative (FN) findings (8 WHO II, 1 WHO III, 2 WHO IV) occurred. There were no false-positive (FP) findings. For the differentiation of primary brain tumours and non-neoplastic lesions, sensitivity and specificity were 78 and 100%. In 34 lesions without contrast enhancement in MRI, IPA SPECT resulted in 17 TP, 8 true-negative, 9 FN and no FP findings (sensitivity 65%, specificity 100%). In patients with suspected glioma, IPA SPECT shows a high specificity, but especially in low-grade gliomas FN findings may occur. Due to the high positive predictive value a positive finding allows a suspected glioma to be confirmed. (orig.)

  1. The study on regional brain blood flow in the patients with Parkinson's disease using 99Tcm-ECD SPECT

    International Nuclear Information System (INIS)

    Sun Da; Ye Xiaojuan; Zhan Hongwei; Xu Wei; Bao Chengkan

    2010-01-01

    Purpose The aim of this study is to evaluate the changes of brain blood floe in patients with Parkinson's disease (PD) and to investigate the clinical characteristics of the patients with PD correlate with rCBF. Methods: Regional cerebral perfusion was investigated using SPECT in 34 patients with PD . The mean ages of the patients were 56.61±11.04 Years old. The course of disease in most patients was from 1 to over 20 years. Results: 94.1 per cent of patients (32/3) had a significant decrease of rCBF in the basal ganglia, frontal lobes, temporal lobes and thalamus. Parietal and occipital cortex were involved in some patients. The decrease of rCBF in the basal ganglia is unilateral in most patients with PD. There were over 3 brain regions that Conclusion: According to our results, patients with PD had decreased rCBF in the basal ganglia, frontal and temporal cortices. These may reflect a fundamental feature of clinical neuropathophysiology in PD. 99 Tc m -ECD SPECT imaging is helpful to the diagnosis of PD and may help investigate the potential pathophysiology of PD. (authors)

  2. Examination performances of German and international medical students in the preclinical studying-term--a descriptive study.

    Science.gov (United States)

    Huhn, D; Resch, F; Duelli, R; Möltner, A; Huber, J; Karimian Jazi, K; Amr, A; Eckart, W; Herzog, W; Nikendei, C

    2014-01-01

    Medical students with a migration background face several specific problems during their studies. International surveys show first indications that this group of students performs worse in written, oral or practical exams. However, so far, nothing is known about the performance of international students in written pre-clinical tests as well as in pre-clinical State Examinations for German-speaking countries. A descriptive, retrospective analysis of the exam performances of medical students in the pre-clinical part of their studies was conducted at the Faculty of Medicine of Heidelberg in for the year 2012. Performance in written tests of the final exams in the second (N=276), third (N=292) and fourth semester (N=285) were compared between German students, students from EU countries and students from non-EU countries. Same comparison was drawn for the performance in the oral exam of the First State Examination in the period from 2009 - 2012 (N=1137). German students performed significantly better than students with a non-EU migration background both in all written exams and in the oral State Examination (all pstudents with an EU migration background was significantly better than that of students with a non-EU background in the written exam at the end of the third and fourth semester (pstudents completed the oral exam of the First State Examination significantly earlier than students with a non-EU migration background (students with a country of origin outside of the European Union has to be seen as a high-risk group among students with a migration background. For this group, there is an urgent need for early support to prepare for written and oral examinations.

  3. Examination performances of German and international medical students in the preclinical studying-term – A descriptive study

    Science.gov (United States)

    Huhn, D.; Resch, F.; Duelli, R.; Möltner, A.; Huber, J.; Karimian Jazi, K.; Amr, A.; Eckart, W.; Herzog, W.; Nikendei, C.

    2014-01-01

    Introduction: Medical students with a migration background face several specific problems during their studies. International surveys show first indications that this group of students performs worse in written, oral or practical exams. However, so far, nothing is known about the performance of international students in written pre-clinical tests as well as in pre-clinical State Examinations for German-speaking countries. Method: A descriptive, retrospective analysis of the exam performances of medical students in the pre-clinical part of their studies was conducted at the Faculty of Medicine of Heidelberg in for the year 2012. Performance in written tests of the final exams in the second (N=276), third (N=292) and fourth semester (N=285) were compared between German students, students from EU countries and students from non-EU countries. Same comparison was drawn for the performance in the oral exam of the First State Examination in the period from 2009 - 2012 (N=1137). Results: German students performed significantly better than students with a non-EU migration background both in all written exams and in the oral State Examination (all pstudents with an EU migration background was significantly better than that of students with a non-EU background in the written exam at the end of the third and fourth semester (pstudents completed the oral exam of the First State Examination significantly earlier than students with a non-EU migration background (students with a country of origin outside of the European Union has to be seen as a high-risk group among students with a migration background. For this group, there is an urgent need for early support to prepare for written and oral examinations. PMID:25228931

  4. Organ volume estimation using SPECT

    CERN Document Server

    Zaidi, H

    1996-01-01

    Knowledge of in vivo thyroid volume has both diagnostic and therapeutic importance and could lead to a more precise quantification of absolute activity contained in the thyroid gland. In order to improve single-photon emission computed tomography (SPECT) quantitation, attenuation correction was performed according to Chang's algorithm. The dual-window method was used for scatter subtraction. We used a Monte Carlo simulation of the SPECT system to accurately determine the scatter multiplier factor k. Volume estimation using SPECT was performed by summing up the volume elements (voxels) lying within the contour of the object, determined by a fixed threshold and the gray level histogram (GLH) method. Thyroid phantom and patient studies were performed and the influence of 1) fixed thresholding, 2) automatic thresholding, 3) attenuation, 4) scatter, and 5) reconstruction filter were investigated. This study shows that accurate volume estimation of the thyroid gland is feasible when accurate corrections are perform...

  5. Preclinical studies on toxicity, antitumour activity and pharmacokinetics of cisplatin and three recently developed derivatives.

    Science.gov (United States)

    Lelieveld, P; Van der Vijgh, W J; Veldhuizen, R W; Van Velzen, D; Van Putten, L M; Atassi, G; Danguy, A

    1984-08-01

    Preclinical studies were performed in mice, rats and dogs of cis-diamminedichloroplatinum(II) (CDDP) and its derivatives cis-1,1-di(aminomethyl) cyclohexane platinum(II) sulphate (TNO-6), cis-diammine-1,1-cyclobutanedicarboxylate platinum(II) (CBDCA) and cis-dichloro, trans-dihydroxybis-isopropylamine platinum(IV) (CHIP). In mice toxicity and antitumour activity were determined. All three derivatives were at least as toxic as CDDP for haemopoietic stem cells and were less active than CDDP against the mouse tumours leukaemia L1210 and osteosarcoma C22LR. Toxicology studies in rats revealed no renal toxicity after a single dose of TNO-6. Fractionated doses of TNO-6 and CBDCA did cause renal toxicity but less than CDDP. CHIP produced little or no kidney damage. In dogs, TNO-6 (1.5 mg/kg) produced more severe kidney damage--although this was reversible--than CDDP (2 mg/kg). Half-lives of distribution were 4.0-5.1 min for TNO-6 and 9.7 min for CDDP, while half-lives of elimination were 3.6-6.6 days and 5.9 days respectively. Plasma levels, normalized for the dose, were at least two times higher after TNO-6 than after CDDP. Twelve weeks after drug administration, plasma levels were undetectable, while tissue concentrations could still be measured. The platinum concentration in kidney cortex was higher after CDDP than after TNO-6.

  6. MR guided spatial normalization of SPECT scans

    International Nuclear Information System (INIS)

    Crouch, B.; Barnden, L.R.; Kwiatek, R.

    2010-01-01

    Full text: In SPECT population studies where magnetic resonance (MR) scans are also available, the higher resolution of the MR scans allows for an improved spatial normalization of the SPECT scans. In this approach, the SPECT images are first coregistered to their corresponding MR images by a linear (affine) transformation which is calculated using SPM's mutual information maximization algorithm. Non-linear spatial normalization maps are then computed either directly from the MR scans using SPM's built in spatial normalization algorithm, or, from segmented TI MR images using DARTEL, an advanced diffeomorphism based spatial normalization algorithm. We compare these MR based methods to standard SPECT based spatial normalization for a population of 27 fibromyalgia patients and 25 healthy controls with spin echo T 1 scans. We identify significant perfusion deficits in prefrontal white matter in FM patients, with the DARTEL based spatial normalization procedure yielding stronger statistics than the standard SPECT based spatial normalization. (author)

  7. Brain imaging during seizure: ictal brain SPECT

    International Nuclear Information System (INIS)

    Kottamasu, Sambasiva Rao

    1997-01-01

    The role of single photon computed tomography (SPECT) in presurgical localization of medically intractable complex partial epilepsy (CPE) in children is reviewed. 99m Technetium neurolite, a newer lipophylic agent with a high first pass brain extraction and little or no redistribution is injected during a seizure, while the child is monitored with a video recording and continuous EEG and SPECT imaging is performed in the next 1-3 hours with the images representing regional cerebral profusion at the time of injection. On SPECT studies performed with radiopharmaceutical injected during a seizure, ictal focus is generally hypervascular. Other findings on ictal brain SPECT include hypoperfusion of adjacent cerebral cortex and white matter, hyperperfusion of contralateral motor cortex, hyperperfusion of ipsilateral basal ganglia and thalamus, brain stem and contralateral cerebellum. Ictal brain SPECT is non-invasive, cost effective and highly sensitive for localization of epileptic focus in patients with intractable CPE. (author)

  8. Direct comparison study between FDG-PET and IMP-SPECT for diagnosing Alzheimer's disease using 3D-SSP analysis in the same patients

    International Nuclear Information System (INIS)

    Nihashi, Takashi; Hayasaka, Kazumasa; Yatsuya, Hiroshi

    2007-01-01

    The purpose of this study was to evaluate and compare the diagnostic ability of 2-[ 18 F]-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) and N-isopropyl-p- 123 I iodoamphetamine single photon emission computed tomography (IMP-SPECT) using three-dimensional stereotactic surface projections (3D-SSP) in patients with moderate Alzheimer's disease (AD). FDG-PET and IMP-SPECT were performed within 3 months in 14 patients with probable moderate AD. Z-score maps of FDG-PET and IMP-SPECT images of a patient were obtained by comparison with data obtained from control subjects. Four expert physicians evaluated and graded the glucose hypometabolism and regional cerebral blood flow (rCBF), focusing in particular on the posterior cingulate gyri/precunei and parietotemporal regions, and determined the reliability for AD. Receiver operating characteristic (ROC) curves were applied to the results for clarification. To evaluate the correlation between two modalities, the regions of interest (ROIs) were set in the posterior cingulate gyri/precunei and parietotemporal region on 3D-SSP images, and mean Z-values were calculated. No significant difference was observed in the area under the ROC curve (AUC) between FDG-PET and IMP-SPECT images (FDG-PET 0.95, IMP-SPECT 0.94). However, a significant difference (P<0.05) was observed in the AUC for the posterior cingulate gyri/precuneus (FDG-PET 0.94, IMP-SPECT 0.81). The sensitivity and specificity of each modality were 86%, and 97% for FDG-PET and 70% and 100% for IMP-SPECT. We could find no significant difference between FDG-PET and IMP-SPECT in terms of diagnosing moderate AD using 3D-SSP. There was a high correlation between the two modalities in the parietotemporal region (Spearman's r=0.82, P<0.001). The correlation in the posterior cingulate gyri/precunei region was lower than that in the parietotemporal region (Spearman's r=0.63, P<0.016). (author)

  9. Pre and post operative evaluation of the perfusion reserve by acetazolamide 99mTc-HMPAO SPECT in patients with chronic occlusive cerebral arteries. A comparative study with PET

    International Nuclear Information System (INIS)

    Kuwabara, Yasuo; Ichiya, Yuichi; Sasaki, Masayuki; Akashi, Yuko; Yoshida, Tsuyoshi; Fukumura, Toshimitsu; Masuda, Kouji; Fujii, Kiyotaka; Fukui, Masashi

    1994-01-01

    We studied the pre and post-operative perfusion reserve using Diamox 99m Tc-HMPAO SPECT in 7 patients with chronic occlusive cerebral arteries and then compared the results with PET. STAMCA anastomosis was performed on 5 patients, while a carotid endarterectomy was done on 2 patients. The cerebral blood flow, the vascular response to CO 2 or Diamox, the oxygen extraction fraction and transit time (CBV/CBF) were measured by PET. In the pre-operative state, the visual evaluations for hypoperfusion area at rest agreed in 5 out of 7 patients in HMPAO SPECT and PET studies. In the remaining 2 patients, hypoperfusion areas were only detected in the PET study. The pre-operative evaluation of perfusion reserve agreed in 2 patients. In the remaining 5 patients, 3 patients showed definite positive (++) in PET and positive (+) in HMPAO SPECT, and one patient showed positive (+) in PET and negative (-) in HMPAO SPECT. The post-operative change of hypoperfusion areas well agreed in HMPAO SPECT and PET studies. However, the change of perfusion reserve was underestimated in HMPAO SPECT compared with PET. In the semiquantitative and quantitative analyses, the count rate ratios (affected/unaffected side) in HMPAO SPECT were apparently higher than those of CBF in PET. The postoperative change of the count rate ratios in HMPAO SPECT were smaller than those of CBF in PET. There was no significant correlation between the change in the ratio of the HMPAO SPECT after the administration of Diamox and the oxygen extraction fraction, and it was thus thought to be impossible to predict the areas with an increased oxygen extraction fraction. Thus, Diamox HMPAO SPECT may underestimate the areas of hypoperfusion or decrease in perfusion reserve when compared with PET. We should consider these limitations in the evaluation of pre and post operative cerebral hemodynamics. (author)

  10. SPECT imaging with resolution recovery

    International Nuclear Information System (INIS)

    Bronnikov, A. V.

    2011-01-01

    Single-photon emission computed tomography (SPECT) is a method of choice for imaging spatial distributions of radioisotopes. Many applications of this method are found in nuclear industry, medicine, and biomedical research. We study mathematical modeling of a micro-SPECT system by using a point-spread function (PSF) and implement an OSEM-based iterative algorithm for image reconstruction with resolution recovery. Unlike other known implementations of the OSEM algorithm, we apply en efficient computation scheme based on a useful approximation of the PSF, which ensures relatively fast computations. The proposed approach can be applied with the data acquired with any type of collimators, including parallel-beam fan-beam, cone-beam and pinhole collimators. Experimental results obtained with a micro SPECT system demonstrate high efficiency of resolution recovery. (authors)

  11. Copper-64 Dichloride as Theranostic Agent for Glioblastoma Multiforme: A Preclinical Study

    Directory of Open Access Journals (Sweden)

    Cristina Ferrari

    2015-01-01

    Full Text Available Glioblastoma multiforme (GBM is the most common primary malignant brain tumor in adults with a median survival time less than one year. To date, there are only a limited number of effective agents available for GBM therapy and this does not seem to add much survival advantage over the conventional approach based on surgery and radiotherapy. Therefore, the development of novel therapeutic approaches to GBM is essential and those based on radionuclide therapy could be of significant clinical impact. Experimental evidence has clearly demonstrated that cancer cells have a particularly high fractional content of copper inside the nucleus compared to normal cells. This behavior can be conveniently exploited both for diagnosis and for delivering therapeutic payloads (theranostic of the radionuclide copper-64 into the nucleus of cancerous cells by intravenous administration of its simplest chemical form as dichloride salt [64Cu]CuCl2. To evaluate the potential theranostic role of [64Cu]CuCl2 in GBM, the present work reports results from a preclinical study carried out in a xenografted GBM tumor mouse model. Biodistribution data of this new agent were collected using a small-animal PET tomograph. Subsequently, groups of tumor implanted nude mice were treated with [64Cu]CuCl2 to simulate single- and multiple-dose therapy protocols, and results were analyzed to estimate therapeutic efficacy.

  12. A Patient-Derived Xenograft Model of Parameningeal Embryonal Rhabdomyosarcoma for Preclinical Studies

    Directory of Open Access Journals (Sweden)

    Jody E. Hooper

    2015-01-01

    Full Text Available Embryonal rhabdomyosarcoma (eRMS is one of the most common soft tissue sarcomas in children and adolescents. Parameningeal eRMS is a variant that is often more difficult to treat than eRMS occurring at other sites. A 14-year-old female with persistent headaches and rapid weight loss was diagnosed with parameningeal eRMS. She progressed and died despite chemotherapy with vincristine, actinomycin-D, and cyclophosphamide plus 50.4 Gy radiation therapy to the primary tumor site. Tumor specimens were acquired by rapid autopsy and tumor tissue was transplanted into immunodeficient mice to create a patient-derived xenograft (PDX animal model. As autopsy specimens had an ALK R1181C mutation, PDX tumor bearing animals were treated with the pan-kinase inhibitor lestaurtinib but demonstrated no decrease in tumor growth, suggesting that single agent kinase inhibitor therapy may be insufficient in similar cases. This unique parameningeal eRMS PDX model is publicly available for preclinical study.

  13. Modeling Acute Traumatic Hemorrhagic Shock Injury: Challenges and Guidelines for Preclinical Studies.

    Science.gov (United States)

    Tremoleda, Jordi L; Watts, Sarah A; Reynolds, Penny S; Thiemermann, Christoph; Brohi, Karim

    2017-12-01

    Trauma is responsible for a large proportion of the world's burden of disease, and is by far the biggest killer of young adults. Hemorrhage is the leading cause of preventable death and its effects are directly correlated with the incidence multi-organ failure in survivors. Trauma research is challenging due to patient heterogeneity, limited randomized controlled trials, and in vitro studies that fail to mimic the systemic injury response. Preclinical research remains essential for mechanistic and therapeutic discovery. Yet modeling the multifaceted nature of traumatic injury poses important experimental and welfare challenges associated with the onset of injury and prehospital and intra-operative care, the limited inter-species validation of coagulation profiles, the use of anesthesia/analgesia, and its impact on the systemic response to trauma; and the challenge of sustaining intensive care in recovery models. Proper model selection depends on the purpose of a given model and the criteria by which the experimental readouts will be clinically relevant. Such complexity warrants further refinement of experimental methodology and outcome measures to improve its clinical efficacy, while ensuring animal well-being. We review the experimental methodologies currently used for modeling traumatic hemorrhagic shock and addressing their impact on clinical translation. The aim of the review is to improve transparency and form a consensus when reporting methodology in trauma modeling.

  14. Dopamine transporter imaging in the aged rat: a [123I]FP-CIT SPECT study

    International Nuclear Information System (INIS)

    Niñerola-Baizán, Aida; Rojas, Santiago; Roé-Vellvé, Núria; Lomeña, Francisco; Ros, Domènec

    2015-01-01

    Introduction: Rodent models are extensively used to assess the biochemical and physiological changes associated with aging. They play a major role in the development of therapies for age-related pathologies such as Parkinson's disease. To validate the usefulness of these animal models in aging or age-related disease research, the consistency of cerebral aging processes across species must be evaluated. The dopaminergic system seems particularly susceptible to the aging process. One of the results of this susceptibility is a decline in striatal dopamine transporter (DAT) availability. Methods: We sought to ascertain whether similar age changes could be detected in-vivo in rats, using molecular imaging techniques such as single photon emission computed tomography (SPECT) with [ 123 I]FP-CIT. Results: A significant decrease of 17.21% in the striatal specific uptake ratio was observed in the aged rats with respect to the young control group. Conclusions: Our findings suggest that age-related degeneration in the nigrostriatal track is similar in humans and rats, which supports the use of this animal in models to evaluate the effect of aging on the dopaminergic system. Advances in Knowledge and Implications for patient Care: Our findings indicate that age-related degeneration in the nigrostriatal track is similar in humans and rats and that these changes can be monitored in vivo using small animal SPECT with [ 123 I]FP-CIT, which could facilitate the translational research in rat models of age related disorders of dopaminergic system

  15. Radiopharmaceuticals for SPECT cancer detection

    Energy Technology Data Exchange (ETDEWEB)

    Chernov, V. I., E-mail: chernov@oncology.tomsk.ru; Medvedeva, A. A., E-mail: tickayaAA@oncology.tomsk.ru; Zelchan, R. V., E-mail: r.zelchan@yandex.ru; Sinilkin, I. G., E-mail: sinilkinig@oncology.tomsk.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation); Stasyuk, E. S.; Larionova, L. A. [Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation); Slonimskaya, E. M.; Choynzonov, E. L. [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation)

    2016-08-02

    The purpose of the study was to assess the efficacy of single photon emission computed tomography (SPECT) with {sup 199}Tl and {sup 99}mTc-MIBI in the detection of breast, laryngeal and hypopharyngeal cancers. A total of 220 patients were included into the study: 120 patients with breast lesions (100 patients with breast cancer and 20 patients with benign breast tumors) and 100 patients with laryngeal/hypopharyngeal diseases (80 patients with laryngeal/hypopharyngeal cancer and 20 patients with benign laryngeal/hypopharyngeal lesions). No abnormal {sup 199}Tl uptake was seen in all patients with benign breast and laryngeal lesions, indicating a 100% specificity of {sup 199}Tl SPECT. In the breast cancer patients, the increased {sup 199}Tl uptake in the breast was visualized in 94.8% patients, {sup 99m}Tc-MIBI—in 93.4% patients. The increased {sup 199}Tl uptake in axillary lymph nodes was detected in 60% patients, and {sup 99m}Tc-MIBI—in 93.1% patients. In patients with laryngeal/hypopharyngeal cancer, the sensitivity of SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI was 95%. The {sup 199}Tl SPECT sensitivity in identification of regional lymph node metastases in the patients with laryngeal/hypopharyngeal cancer was 75% and the {sup 99m}Tc-MIBI SPECT sensitivity was 17%. The data obtained showed that SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI can be used as one of the additional imaging methods in detection of tumors.

  16. Facilitating healthcare decisions by assessing the certainty in the evidence from preclinical animal studies

    Science.gov (United States)

    Hooijmans, Carlijn R.; de Vries, Rob B. M.; Ritskes-Hoitinga, Merel; Rovers, Maroeska M.; Leeflang, Mariska M.; IntHout, Joanna; Wever, Kimberley E.; Hooft, Lotty; de Beer, Hans; Kuijpers, Ton; Macleod, Malcolm R.; Sena, Emily S.; ter Riet, Gerben; Morgan, Rebecca L.; Thayer, Kristina A.; Rooney, Andrew A.; Guyatt, Gordon H.; Schünemann, Holger J.

    2018-01-01

    Laboratory animal studies are used in a wide range of human health related research areas, such as basic biomedical research, drug research, experimental surgery and environmental health. The results of these studies can be used to inform decisions regarding clinical research in humans, for example the decision to proceed to clinical trials. If the research question relates to potential harms with no expectation of benefit (e.g., toxicology), studies in experimental animals may provide the only relevant or controlled data and directly inform clinical management decisions. Systematic reviews and meta-analyses are important tools to provide robust and informative evidence summaries of these animal studies. Rating how certain we are about the evidence could provide important information about the translational probability of findings in experimental animal studies to clinical practice and probably improve it. Evidence summaries and certainty in the evidence ratings could also be used (1) to support selection of interventions with best therapeutic potential to be tested in clinical trials, (2) to justify a regulatory decision limiting human exposure (to drug or toxin), or to (3) support decisions on the utility of further animal experiments. The Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) approach is the most widely used framework to rate the certainty in the evidence and strength of health care recommendations. Here we present how the GRADE approach could be used to rate the certainty in the evidence of preclinical animal studies in the context of therapeutic interventions. We also discuss the methodological challenges that we identified, and for which further work is needed. Examples are defining the importance of consistency within and across animal species and using GRADE’s indirectness domain as a tool to predict translation from animal models to humans. PMID:29324741

  17. Facilitating healthcare decisions by assessing the certainty in the evidence from preclinical animal studies.

    Science.gov (United States)

    Hooijmans, Carlijn R; de Vries, Rob B M; Ritskes-Hoitinga, Merel; Rovers, Maroeska M; Leeflang, Mariska M; IntHout, Joanna; Wever, Kimberley E; Hooft, Lotty; de Beer, Hans; Kuijpers, Ton; Macleod, Malcolm R; Sena, Emily S; Ter Riet, Gerben; Morgan, Rebecca L; Thayer, Kristina A; Rooney, Andrew A; Guyatt, Gordon H; Schünemann, Holger J; Langendam, Miranda W

    2018-01-01

    Laboratory animal studies are used in a wide range of human health related research areas, such as basic biomedical research, drug research, experimental surgery and environmental health. The results of these studies can be used to inform decisions regarding clinical research in humans, for example the decision to proceed to clinical trials. If the research question relates to potential harms with no expectation of benefit (e.g., toxicology), studies in experimental animals may provide the only relevant or controlled data and directly inform clinical management decisions. Systematic reviews and meta-analyses are important tools to provide robust and informative evidence summaries of these animal studies. Rating how certain we are about the evidence could provide important information about the translational probability of findings in experimental animal studies to clinical practice and probably improve it. Evidence summaries and certainty in the evidence ratings could also be used (1) to support selection of interventions with best therapeutic potential to be tested in clinical trials, (2) to justify a regulatory decision limiting human exposure (to drug or toxin), or to (3) support decisions on the utility of further animal experiments. The Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) approach is the most widely used framework to rate the certainty in the evidence and strength of health care recommendations. Here we present how the GRADE approach could be used to rate the certainty in the evidence of preclinical animal studies in the context of therapeutic interventions. We also discuss the methodological challenges that we identified, and for which further work is needed. Examples are defining the importance of consistency within and across animal species and using GRADE's indirectness domain as a tool to predict translation from animal models to humans.

  18. Motor activation SPECT for the neurosurgical diseases. Clinical application

    International Nuclear Information System (INIS)

    Noguchi, Hiroshi; Kawaguchi, Shoichiro; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    1999-01-01

    We evaluated and analyzed the motor activation single photon emission computed tomography (M-SPECT) findings on patients with ischemic cerebrovascular diseases (CVD). The M-SPECT studies were carried out on 91 patients with ischemic cerebrovascular diseases. The M-SPECT study was performed using the finger opposition task in each case. The SPECT images were superimposed on the magnetic resonance images (MRIs) for each case using Image Fusion Software. The result of the M-SPECT was expressed as positive or negative. The cases with a marked increase of blood flow in the sensorio-motor cortex after the finger opposition task were categorized as positive, and those cases showing no marked increase of blood flow were categorized as negative. Among the 91 cases examined, 53 (58%) were categorized as positive in the M-SPECT study. Among the negative M-SPECT cases treated with revascularization surgery, there were some cases showing positive M-SPECT results postoperatively. The cases without any revascularization surgery did not change the M-SPECT findings in each during the follow-up period. The M-SPECT procedure for examining intracranial lesions could provide the cortical localization of the motor function. The M-SPECT procedure in the ischemic CVDs contributes to knowledge about the choices of treatment and the evaluation of the treatment result. (author)

  19. Motor activation SPECT for the neurosurgical diseases. Clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Hiroshi; Kawaguchi, Shoichiro; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    1999-08-01

    We evaluated and analyzed the motor activation single photon emission computed tomography (M-SPECT) findings on patients with ischemic cerebrovascular diseases (CVD). The M-SPECT studies were carried out on 91 patients with ischemic cerebrovascular diseases. The M-SPECT study was performed using the finger opposition task in each case. The SPECT images were superimposed on the magnetic resonance images (MRIs) for each case using Image Fusion Software. The result of the M-SPECT was expressed as positive or negative. The cases with a marked increase of blood flow in the sensorio-motor cortex after the finger opposition task were categorized as positive, and those cases showing no marked increase of blood flow were categorized as negative. Among the 91 cases examined, 53 (58%) were categorized as positive in the M-SPECT study. Among the negative M-SPECT cases treated with revascularization surgery, there were some cases showing positive M-SPECT results postoperatively. The cases without any revascularization surgery did not change the M-SPECT findings in each during the follow-up period. The M-SPECT procedure for examining intracranial lesions could provide the cortical localization of the motor function. The M-SPECT procedure in the ischemic CVDs contributes to knowledge about the choices of treatment and the evaluation of the treatment result. (author)

  20. Diagnoses behind patients with hard-to-classify tremor and normal DaT-SPECT: A clinical follow up study

    Directory of Open Access Journals (Sweden)

    Manuel eMenéndez-González

    2014-04-01

    Full Text Available The [123I]ioflupane - a dopamine transporter radioligand - SPECT (DaT-SPECT has proven to be useful in the differential diagnosis of tremor. Here, we investigate the diagnoses behind patients with hard-to-classify tremor and normal DaT-SPECT. Therefore, 30 patients with tremor and normal DaT-SPECT were followed up for 2 years. In 18 cases we were able to make a diagnosis. The residual 12 patients underwent a second DaT-SPECT, were then followed for additional 12 months and thereafter the diagnosis was reconsidered again. The final diagnoses included cases of essential tremor, dystonic tremor, multisystem atrophy, vascular parkinsonism, progressive supranuclear palsy, corticobasal degeneration, fragile X–associated tremor ataxia syndrome, psychogenic parkinsonism, iatrogenic parkinsonism and Parkinson’s disease. However, for 6 patients the diagnosis remained uncertain. Larger series are needed to better establish the relative frequency of the different conditions behind these cases.

  1. Diagnoses behind patients with hard-to-classify tremor and normal DaT-SPECT: a clinical follow up study.

    Science.gov (United States)

    Menéndez-González, Manuel; Tavares, Francisco; Zeidan, Nahla; Salas-Pacheco, José M; Arias-Carrión, Oscar

    2014-01-01

    The [(123)I]ioflupane-a dopamine transporter radioligand-SPECT (DaT-SPECT) has proven to be useful in the differential diagnosis of tremor. Here, we investigate the diagnoses behind patients with hard-to-classify tremor and normal DaT-SPECT. Therefore, 30 patients with tremor and normal DaT-SPECT were followed up for 2 years. In 18 cases we were able to make a diagnosis. The residual 12 patients underwent a second DaT-SPECT, were then followed for additional 12 months and thereafter the diagnosis was reconsidered again. The final diagnoses included cases of essential tremor, dystonic tremor, multisystem atrophy, vascular parkinsonism, progressive supranuclear palsy, corticobasal degeneration, fragile X-associated tremor ataxia syndrome, psychogenic parkinsonism, iatrogenic parkinsonism and Parkinson's disease. However, for 6 patients the diagnosis remained uncertain. Larger series are needed to better establish the relative frequency of the different conditions behind these cases.

  2. SPECT in psychiatry. SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Barocka, A. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Feistel, H. (Nuklearmedizinische Klinik, Erlangen (Germany)); Ebert, D. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Lungershausen, E. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany))

    1993-08-13

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D[sub 2] and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.)

  3. Varenicline increases in vivo striatal dopamine D2/3 receptor binding: an ultra-high-resolution pinhole [123I]IBZM SPECT study in rats

    International Nuclear Information System (INIS)

    Crunelle, Cleo L.; Wit, Tim C. de; Bruin, Kora de; Ramakers, Ruud M.; Have, Frans van der; Beekman, Freek J.; Brink, Wim van den; Booij, Jan

    2012-01-01

    Introduction: Ex vivo storage phosphor imaging rat studies reported increased brain dopamine D 2/3 receptor (DRD 2/3 ) availability following treatment with varenicline, a nicotinergic drug. However, ex vivo studies can only be performed using cross-sectional designs. Small-animal imaging offers the opportunity to perform serial assessments. We evaluated whether high-resolution pinhole single photon emission computed tomography (SPECT) imaging in rats was able to reproduce previous ex vivo findings. Methods: Rats were imaged for baseline striatal DRD 2/3 availability using ultra-high-resolution pinhole SPECT (U-SPECT-II) and [ 123 I]IBZM as a radiotracer, and randomized to varenicline (n=7; 2 mg/kg) or saline (n=7). Following 2 weeks of treatment, a second scan was acquired. Results: Significantly increased striatal DRD 2/3 availability was found following varenicline treatment compared to saline (time⁎treatment effect): posttreatment difference in binding potential between groups corrected for initial baseline differences was 2.039 (P=.022), indicating a large effect size (d=1.48). Conclusions: Ultra-high-resolution pinhole SPECT can be used to assess varenicline-induced changes in DRD 2/3 availability in small laboratory animals over time. Future small-animal studies should include imaging techniques to enable repeated within-subjects measurements and reduce the amount of animals.

  4. Prognostic study of cardiac events in Japanese high risk hemodialysis patients using I-BMIPP-SPECT: B-SAFE study design.

    Science.gov (United States)

    Hasebe, Naoyuki; Moroi, Masao; Nishimura, Masato; Hara, Kazuhiro; Hase, Hiroki; Hashimoto, Akiyoshi; Kumita, Shinichiro; Haze, Kazuo; Momose, Mitsuru; Nagai, Yoji; Sugimoto, Tokuichiro; Kusano, Eiji; Akiba, Takashi; Nakata, Tomoaki; Nishimura, Tsunehiko; Tamaki, Nagara; Kikuchi, Kenjiro

    2008-12-01

    Cardiovascular disease is the leading cause of morbidity and mortality in patients undergoing hemodialysis. Such patients frequently develop complications such as asymptomatic coronary artery disease (CAD). Accordingly, CAD must ideally be diagnosed at an early stage to improve prognosis. Although myocardial perfusion single photon emission computed tomography (SPECT) is valuable for diagnosing CAD, the stress test is not always applicable to patients on hemodialysis. Thus, we proposed a multicenter, prospective cohort study called "B-SAFE" to investigate the applicability of resting (123)I-labeled beta-methyl-iodophenylpentadecanoic acid ((123)I-BMIPP)-SPECT will be used to diagnose cardiac disease and evaluate the prognosis of hemodialysis patients by imaging myocardial fatty acid metabolism. B-SAFE began enrolling patients from June 2006 at 48 facilities. We performed (123)I-BMIPP-SPECT on 702 hemodialysis patients with risk factors for CAD until 30 November 2007 and plan to follow up for three years. The primary endpoints will be cardiac death and sudden death. This study should end in 2010.

  5. Miltefosine Lipid Nanocapsules for Single Dose Oral Treatment of Schistosomiasis Mansoni: A Preclinical Study.

    Directory of Open Access Journals (Sweden)

    Maha M Eissa

    Full Text Available Miltefosine (MFS is an alkylphosphocholine used for the local treatment of cutaneous metastases of breast cancer and oral therapy of visceral leishmaniasis. Recently, the drug was reported in in vitro and preclinical studies to exert significant activity against different developmental stages of schistosomiasis mansoni, a widespread chronic neglected tropical disease (NTD. This justified MFS repurposing as a potential antischistosomal drug. However, five consecutive daily 20 mg/kg doses were needed for the treatment of schistosomiasis mansoni in mice. The present study aims at enhancing MFS efficacy to allow for a single 20mg/kg oral dose therapy using a nanotechnological approach based on lipid nanocapsules (LNCs as oral nanovectors. MFS was incorporated in LNCs both as membrane-active structural alkylphospholipid component and active antischistosomal agent. MFS-LNC formulations showed high entrapment efficiency (EE%, good colloidal properties, sustained release pattern and physical stability. Further, LNCs generally decreased MFS-induced erythrocyte hemolytic activity used as surrogate indicator of membrane activity. While MFS-free LNCs exerted no antischistosomal effect, statistically significant enhancement was observed with all MFS-LNC formulations. A maximum effect was achieved with MFS-LNCs incorporating CTAB as positive charge imparting agent or oleic acid as membrane permeabilizer. Reduction of worm load, ameliorated liver pathology and extensive damage of the worm tegument provided evidence for formulation-related efficacy enhancement. Non-compartmental analysis of pharmacokinetic data obtained in rats indicated independence of antischistosomal activity on systemic drug exposure, suggesting possible gut uptake of the stable LNCs and targeting of the fluke tegument which was verified by SEM. The study findings put forward MFS-LNCs as unique oral nanovectors combining the bioactivity of MFS and biopharmaceutical advantages of LNCs

  6. Reconstitution of immunodeficient SCID/beige mice with human cells: Applications in preclinical studies

    International Nuclear Information System (INIS)

    Thomsen, Mogens; Galvani, Sylvain; Canivet, Cindy; Kamar, Nassim; Boehler, Torsten

    2008-01-01

    Experimental studies of the in vivo behaviour of human cells and tissues have become possible with the development of immunodeficient mice strains. Such mice accept readily allogeneic or xenogeneic grafts, including grafts of human cells or tissues, without rejection. In this review we describe different immunodeficient mouse strains that have been used for reconstitution by human immune cells. We subsequently go through the experience that we and others have had with reconstitution, and mention the adverse effects, in particular xenogeneic graft versus host reactions. The use of haematopoietic stem cells avoids such reactions but the immunological reconstitution may take several months. We then report the use of immunodeficient mice for the study of chronic vascular rejection of human mesenteric arteries due to cellular or humoral alloreaction. We have shown that SCID/beige mice grafted with a human artery at the place of the aorta developed a thickening of the intima of the human artery after 5-6 weeks, when they were reconstituted with spleen cells from another human donor. The thickening is mainly due to a proliferation of smooth muscle cells. The same type of lesion developed if they received injection of antibodies towards HLA class I antigens. The arteries of the mouse did not develop any lesion. The arterial lesions closely resembled those seen after clinical organ transplantation. Mice that received spleen cells from the same human donor developed little or no lesions. An important aspect of this experimental transplantation model is the possibility to test drugs that may be used in clinical transplantation. In recent experiments we have shown that novel immunosuppressive drugs can inhibit the hyperproliferation of smooth muscle cells in vitro. Preclinical testing in reconstituted SCID/beige mice grafted with human arteries will permit the evaluation of the potential use of these drugs to prevent chronic vascular rejection. The model also allows

  7. Iterative reconstruction or filtered backprojection for semi-quantitative assessment of dopamine D2 receptor SPECT studies?

    International Nuclear Information System (INIS)

    Koch, Walter; Suessmair, Christine; Tatsch, Klaus; Poepperl, Gabriele

    2011-01-01

    In routine clinical practice striatal dopamine D 2 receptor binding is generally assessed using data reconstructed by filtered backprojection (FBP). The aim of this study was to investigate the use of an iterative reconstruction algorithm (ordered subset expectation maximization, OSEM) and to assess whether it may provide comparable or even better results than those obtained by standard FBP. In 56 patients with parkinsonian syndromes, single photon emission computed tomography (SPECT) scans were acquired 2 h after i.v. application of 185 MBq [ 123 I]iodobenzamide (IBZM) using a triple-head gamma camera (Siemens MS 3). The scans were reconstructed both by FBP and OSEM (3 iterations, 8 subsets) and filtered using a Butterworth filter. After attenuation correction the studies were automatically fitted to a mean template with a corresponding 3-D volume of interest (VOI) map covering striatum (S), caudate (C), putamen (P) and several reference VOIs using BRASS software. Visual assessment of the fitted studies suggests a better separation between C and P in studies reconstructed by OSEM than FBP. Unspecific background activity appears more homogeneous after iterative reconstruction. The correlation shows a good accordance of dopamine receptor binding using FBP and OSEM (intra-class correlation coefficients S: 0.87; C: 0.88; P: 0.84). Receiver-operating characteristic (ROC) analyses show comparable diagnostic power of OSEM and FBP in the differentiation between idiopathic parkinsonian syndrome (IPS) and non-IPS. Iterative reconstruction of IBZM SPECT studies for assessment of the D 2 receptors is feasible in routine clinical practice. Close correlations between FBP and OSEM data suggest that iteratively reconstructed IBZM studies allow reliable quantification of dopamine receptor binding even though a gain in diagnostic power could not be demonstrated. (orig.)

  8. Evaluation of usefulness of bone SPECT for lumbar spondylolysis

    International Nuclear Information System (INIS)

    Watanabe, Osamu; Hashimoto, Manabu; Tomura, Noriaki; Watarai, Jiro

    2002-01-01

    The purpose of this study was to evaluate the usefulness of 99m Tc-MDP SPECT (bone SPECT) for lumbar spondylolysis. We analyzed 11 cases with 17 lesions. All cases were compared using plain radiography, computed tomography (CT), planar bone scintigraphy (PBS), and bone SPECT. Four lesions that showed a wide defect on CT were negative on bone SPECT and may have been chronic lesions. Thirteen lesions that were positive on bone SPECT were narrow or showed no defect on CT and may have been early lesions. Two cases showed no defect on CT but were positive on bone SPECT, and one of them progressed to bilateral spondylolysis after one year. This may have been a very early lesion. Thus bone SPECT is useful for the diagnosis of lumbar spondylolysis, especially in its early stage. (author)

  9. Evaluation of usefulness of bone SPECT for lumbar spondylolysis

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Osamu; Hashimoto, Manabu; Tomura, Noriaki; Watarai, Jiro [Akita Univ. (Japan). School of Medicine

    2002-07-01

    The purpose of this study was to evaluate the usefulness of {sup 99m}Tc-MDP SPECT (bone SPECT) for lumbar spondylolysis. We analyzed 11 cases with 17 lesions. All cases were compared using plain radiography, computed tomography (CT), planar bone scintigraphy (PBS), and bone SPECT. Four lesions that showed a wide defect on CT were negative on bone SPECT and may have been chronic lesions. Thirteen lesions that were positive on bone SPECT were narrow or showed no defect on CT and may have been early lesions. Two cases showed no defect on CT but were positive on bone SPECT, and one of them progressed to bilateral spondylolysis after one year. This may have been a very early lesion. Thus bone SPECT is useful for the diagnosis of lumbar spondylolysis, especially in its early stage. (author)

  10. Assessment of congenital heart disease by a thallium-201 SPECT study in children; Accuracy of estimated right to left ventricular pressure ratio

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Iwao; Nakajima, Kenichi; Taki, Junichi; Taniguchi, Mitsuru; Bunko, Hisashi; Tonami, Norihisa; Hisada, Kinichi; Ohno, Takashi (Kanazawa Univ. (Japan). School of Medicine)

    1993-01-01

    The characteristics of correlation between the right-to-left ventricular systolic pressure ratios (RVp/LVp) and the thallium-201 right-to-left ventricular ([sup 201]Tl R/L) count ratios was investigated in children with various congenital heart diseases. High-resolution three-headed SPECT system equipped with either parallel-hole or fan-beam collimators was used. In a total of 102 patients, the correlation between RVp/LVp and [sup 201]Tl R/L average count ratios was good in both planar (r=0.89, p=0.0001) and SPECT studies (r=0.80, p=0.0001). Quantitative analysis of myocardial uptake by SPECT demonstrated the characteristic pattern of each disease as well as the differences in the right ventricular overload types. When the linear regression analysis was performed in each heart disease, ventricular septal defect showed most excellent correlation. Complex heart anomalies also showed positive correlation (r=0.51, p=0.05) with RVp/LVp, and it can be used to estimate right ventricular pressure. After surgical treatment of tetralogy of Fallot and pulmonary stenosis, the decrease of [sup 201]Tl R/L count ratio was in accordance with improvement of right ventricular overload. We conclude that [sup 201]Tl SPECT study can be a good indicator for estimation of right ventricular pressure. (author).

  11. A study of acetazolamide-induced changes in cerebral blood flow using {sup 99m}Tc HMPAO SPECT in patients with cerebrovascular disease

    Energy Technology Data Exchange (ETDEWEB)

    Asenbaum, S. [Neurological Clinic, Univ. Vienna (Austria); Reinprecht, A. [Neurosurgical Clinic, Univ. Vienna (Austria); Bruecke, T. [Neurological Clinic, Univ. Vienna (Austria); Wenger, S. [Neurological Clinic, Univ. Vienna (Austria); Podreka, I. [Neurological Clinic, Univ. Vienna (Austria); Deecke, L. [Neurological Clinic, Univ. Vienna (Austria)

    1995-01-01

    For semiquantification of SPECT studies we tried to calculate cerebral {sup 99m}Tc-HMPAO uptake related to injected dose and estimated brain volume. The method was applied to SPECT investigations of 27 patients who had a least one ischaemic attack and a confirmed 80-100% stenosis of the corresponding internal carotid artery (ICA). Vascular reactivity was tested by parenteral administration of acetazolamide (AZ). Increase in HMPAO uptake after AZ was evident in both hemispheres, although the increase (AZ effect) was significantly lower in the affected hemisphere (+24% versus +28%). No interhemispheric uptake differences were seen in patients with largely normal SPECT studies, although local asymmetries in HMPAO deposition were visible. Patients with low density lesions on CT and with a well-demarcated lesion in the same location on SPECT revealed interhemispheric uptake differences, with lower uptake on the affected side. This was not due solely to alterations in the lesion, but also to reduced HMPAO uptake and AZ effect in the surrounding area. The AZ effect showed no correlation with angiographic findings, indicating no major haemodynamic influence of the ICA stenosis on cerebral hemisphere perfusion. Calculated cerebral HMPAO uptake changes after AZ administration were in good accordance with absolute cerebral blood flow measurements, and made interindividual comparisons possible. However, as changes in the area around an infarct or local reduction in vascular reserve may not be reproduced adequately by uptake calculations, visual inspection is still necessary. (orig.)

  12. Effect of streptozotocin-induced diabetes on left ventricular function in adult rats: an in vivo Pinhole Gated SPECT study

    Directory of Open Access Journals (Sweden)

    Weytjens Caroline

    2007-10-01

    Full Text Available Abstract Background Recent studies have suggested that diabetes mellitus (DM may cause left ventricular (LV dysfunction directly resulting in increased susceptibility to heart failure. Using pinhole collimators and advances in data processing, gated SPECT was recently adapted to image the rat heart. The present study was aimed to assess this new imaging technique for quantifying LV function and remodeling from the Streptozotocin (STZ rat model compared to controls. Methods Twenty one rats were randomly assigned to control or diabetic group. Six months after the induction of diabetes by STZ, Pinhole 99 m Tc-sestamibi gated SPECT was performed for determining rat LV volumes and function. Post-mortem histopathologic analysis was performed to evaluate the determinant of LV remodeling in this model. Results After six months, the normalized to body weight LV End-systolic volume was significantly different in diabetic rats compared to controls (0.46 ± 0.02 vs 0.33 ± 0.03 μL/g; p = 0.01. The normalized LV End-diastolic volume was also different in both groups (1.51 ± 0.03 vs 0.88 ± 0.05 μL/g; p = 0.001 and the normalized stroke volume was significantly higher in STZ-rats (1.05 ± 0.02 vs 0.54 ± 0.06 μL/g; p = 0.001. The muscular fibers were thinner at histology in the diabetic rats (0.44 ± 0.07 vs 0.32 ± 0.06 AU; p = 0.01. Conclusion Pinhole 99 m Tc-sestamibi gated SPECT can successfully be applied for the evaluation of cardiac function and remodeling in STZ-induced diabetic rats. In this model, LV volumes were significantly changed compared to a control population, leading to a LV dysfunction. These findings were consistent with the histopathological abnormalities. Finally, these data further suggest the presence of diabetes cardiomyopathy.

  13. Evaluation of cerebral metabolism in patients with unilateral carotid stenosis by proton MR spectroscopy: a correlative study with cerebral hemodynamics by acetazolamide stress brain perfusion SPECT (acz-SPECT)

    International Nuclear Information System (INIS)

    Kim, Jae Seung; Kim, Geun Eun; Lee, Jeong Hee; Kim, Do Gyun; Kim, Sang Tae; Lee, Hee Kyung

    2001-01-01

    Carotid stenosis may lead not only to cerebral hemodynamic compromise but also cerebral metabolic changes without overt infarction. To investigate the brain metabolic changes as a result of hemodynamic compromise in pts with carotid stenosis, we compared the changes in metabolism of the gray and white matter detected by proton MRS with cortical hemodynamics measured by Acz-SPECT. We prospectively studied symptomatic 18 pts (M/F=15/3, mean ages: 64.4y) with unilateral carotid stenosis. All pts underwent Acz-SPECT and MRS with 3 days. rCBF and rCVR of MCA territory were assessed by Acz-SPECT. Hemodynamic compromise was graded as stage 0 (normal rCBF and rCVR), stage 1 (normal rCBF and reduced rCVR), and stage 2( reduced rCBF and rCVR). Brain metabolism was assessed by measuring the peaks of N-acetyl aspartate (NAA), choline (Cho), and the sum of creatine and phosphocreatine (Cr) from noninfarcted white matter in the both centrum semiovales and gray matter in both MCA territories. On Acz-SPECT, 7 pts showed stage 2 were significantly lower than in pts with stage 0 (p<0.01). The asymmetric ratio of NAA/Cr in pts with state 2 was also significantly lower than in pts with stage 1(p<0.05). The asymmetric ratio of Cho/Cr was increased as hemodynamic stage increased but the differences were not statistically significant among 3 stages. In cortical gray matter, the asymmetric ratios of NAA/Cho and NAA/Cr were decreased statistically significant among 3 stages. In cortical gray matter, the asymmetric ratios of NAA/Cho and NAA/Cr were decreased and that of Cho/Cr was increased as hemodynamic stage increased. However, these differences were not statistically significant among 3 stages. The asymmetric ratios of NAA/Cho of centrum semiovale in pts with reduced rCBF and/or reduced rCVR were lower than in pts with normal perfusion. Our results indicate the metabolic changes detected by proton MRS in patients with carotid stenosis reflect a hemodynamic compromised state

  14. Characteristics of Effective Simulation (Preclinical) Teachers as Identified by Dental Students: A Qualitative Study.

    Science.gov (United States)

    McAndrew, Maureen; Mucciolo, Thomas W; Jahangiri, Leila

    2016-11-01

    The aim of this qualitative research study was to identify and categorize criteria for simulation teacher quality preferences as reported by dental students. Second-year dental students at New York University College of Dentistry in 2015 were given a two-question, open-ended survey asking what qualities they liked most and least in a simulation or preclinical teacher. Responses were collected until data saturation was reached. Key words in the responses were identified and coded based on similar relationships and then were grouped into defined categories. A total of 168 respondents out of the target group of 363 students (46.3%) provided 1,062 written comments. Three core themes-character, competence, and communication-emerged from 16 defined categories, which were validated using references from the educational literature. The theme of character encompassed eight of the defined categories (motivation, available, caring, patience, professionalism, empathy, fairness, and happiness) and accounted for 50% of the total student responses. The theme of competence comprised five categories (expertise, knowledgeable, efficient, skillful, and effective) and represented 34% of all responses. The communication theme covered the remaining three categories (feedback, approachable, and interpersonal communication) and contained 17% of the responses. Positive and negative comments in the category of motivation accounted for 11.2% of all student responses. Expertise was the next highest category with 9.3% of the responses, followed closely by 9.1% in the category of available. Among these students, the top five attributes of simulation teachers were motivation, expertise, available, caring, and feedback. While the study did not attempt to correlate these findings with improved student performance, the results can be used in the development of assessment tools for faculty and targeted faculty development programs.

  15. PET and SPECT of neurobiological systems

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Gent Univ. (Belgium). Dept. of Nuclear Medicine; Otte, Andreas [Univ. of Applied Sciences, Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-04-01

    Addresses a variety of aspects of neurotransmission in the brain. Details the latest results in probe development. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT of Neurobiological Systems combines the expertise of renowned authors whose dedication to the development of novel probes and techniques for the investigation of neurobiological systems has achieved international recognition. Various aspects of neurotransmission in the brain are discussed, such as visualization and quantification of (more than 20 different) neuroreceptors, neuroinflammatory markers, transporters, and enzymes as well as neurotransmitter synthesis, ?-amyloid deposition, cerebral blood flow, and the metabolic rate of glucose. The latest results in probe development are also detailed. Most chapters are written jointly by radiochemists and nuclear medicine specialists to ensure a multidisciplinary approach. This state of the art compendium will be valuable to anyone in the field of clinical or preclinical neuroscience, from the radiochemist and radiologist/nuclear medicine specialist to the interested neurobiologist and general practitioner. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences. Other volumes focus on PET and SPECT in psychiatry and PET and SPECT in neurology''.

  16. Osseointegration in osteoporotic-like condition: A systematic review of preclinical studies.

    Science.gov (United States)

    Dereka, X; Calciolari, E; Donos, N; Mardas, N

    2018-05-30

    Osteoporosis is one of the most common skeletal disorders affecting a significant percentage of people worldwide. Research data suggested that systemic diseases such as osteoporosis could act as risk factors for osseointegration, jeopardizing the healing process and thus the predictability of dental implant success on compromised patients. It is well accepted that preclinical studies in animal models reproducing the osteoporotic condition are one of the most important stages in the research of new biomaterials and therapeutic modalities. The aim of this systematic review was to investigate whether osteoporosis compromises dental implant osseointegration in experimental osteoporotic-like conditions. A 3-stage systematic literature research was conducted in MEDLINE via OVID and EMBASE up to and including March 2017. Experimental studies reporting on dental implant osseointegration on different osteoporotic animal models were assessed. The studies had to report on the percentage of bone-to-implant contact (%BIC) as the primary outcome. ARRIVE guidelines for reporting on animal research were applied to evaluate the methodological quality and risk of bias of the studies. Fifty-seven studies met the inclusion criteria and were assessed qualitatively. The most adopted animal model was the rat. A variability of %BIC values was observed, ranging from 30% to 99% and from 26% to 94% for the healthy and osteoporotic group, respectively. The great majority (47) of the included studies concluded that estrogen deficiency significantly affects BIC values, 9 studies stated that it was not possible to observe statistical differences in BIC between ovariectomized and healthy groups and 1 study did not provide a comparison between the healthy and osteoporotic group. Owing to the great heterogeneity in implant surface, study design, observation time-points, site of implant placement and reported outcomes, a meta-analysis could not be performed. An overall high risk of bias was observed

  17. SPECT imaging of dopaminergic system: a preliminary study of nine patients with clinically uncertain Parkinsonism

    International Nuclear Information System (INIS)

    Dey, S. K.; Gopinath, G.; Buscombe, J. R.

    2004-01-01

    Parkinsonism is the result of various neuro degenerative disorders, the common and related causes are Parkinson's disease (PD), multiple system atrophy (MSA) and progressive supranuclear palsy (PSP). In each of these three causes, there is degeneration of presynaptic neurons in corpus striatum. Nine patients having clinically uncertain parkinsonian symptoms undergone brain SPECT imaging using the tracer (I-123 Ioflupane) that binds to dopamine transporter (DaT) in the pre-synaptic nerve terminals in basal ganglia. There was significantly decreased tracer uptake in the tail (putamen) portion of basal ganglia in five patients confirming presence of presynaptic neuro degeneration and reported as parkinsonism. Three patients revealed normal tracer uptake with one equivocal result. DaT imaging can effectively confirm parkinsonism and discriminate from normal subjects as well as other clinical simulators like essential tremor and dopa-responsive dystonia where no neuro degeneration occur.(author)

  18. A study of full width at half maximum (FWHM) according to the filter's cut off level in SPECT camera

    Energy Technology Data Exchange (ETDEWEB)

    Park, Soung Ock [Dongnam Health College, Suwon (Korea, Republic of); Kwon, Soo Il [Kyonggi University, Suwon (Korea, Republic of)

    2003-06-15

    Filtering is necessary to reduce statistical noise and to increase image quality in SPECT images. Noises controlled by low-pass filter designed to suppress high spatial frequency in SPECT image. Most SPECT filter function control the degree of high frequency suppression by choosing a cut off frequency. The location of cut off frequency determines the affect image noise and spatial resolution. If select the low cut off frequency, its provide good noise suppression but insufficient image quantity and high cut off frequencies increase the image resolution but insufficient noise suppression. The purpose of this study was to determines the optimum cut off level with comparison of FWHM according to cut off level in each filters-Band-limited, Sheep-logan, Sheep-logan Hanning, Generalized Hamming, Low pass cosine, Parazen and Butterworth filter in SPECT camera. We recorded image along the X, Y, Z-axis with {sup 99m}TcO{sub 4} point source and measured FWHM by use profile curve. We find averaged length is 9.16 mm {approx} 18.14 mm of FWHM in X, Y, and Z-axis, and Band-limited and Generalized Hamming filters measures 9.16 mm at 0.7 cycle/pixel cut off frequency.

  19. An MRI and SPECT study of frozen gait without other manifestations of parkinsonism in the elderly

    International Nuclear Information System (INIS)

    Umahara, Takahiko; Kano, Hiroko; Iwamoto, Toshihiko; Katsunuma, Hideyo; Tachikawa, Kotaro; Tachikawa, Sinzo.

    1991-01-01

    The authors have sometimes experienced cases of frozen gait without any other manifestations of parkinsonisms in the elderly, so we examined these cases using MR imaging and SPECT imaging. The group with frozen gait (4 cases, aged 78 to 82 years) which failed to respond to L-dopa therapy, had no limb-kinetic apraxia or frontal signs, but did exhibit 'kinesie paradoxale'. The clinical symptoms of case 4 were consistent with so-called 'pure akinesia'. CT findings in this group failed to elucidate the pathogenesis of frozen gait. MR imaging of all of the cases except for the case of pure akinesia (case 4) revealed a high signal intensity areas in subcortical lesions (especially the frontal area). Case 4 had only a few spotty high-signal intensity areas. We then compared 6 cases which have the same lesions (on MRI) as cases 1∼3 without frozen gait in cases 1∼3 using 123 I-IMP SPECT. Relatively low accumulation of radionuclide in the frontal area was observed in these cases. Case 4 had a slightly low perfusion area in the frontal lobe. However in the patient treated with L-threo-DOPS, accumulation of radionuclide in the frontal area increased slightly after L-threo-DOPS therapy. It appears that one of the reasons for frozen gait in the elderly is incomplete infarct of the subcortical white matter with a low perfusion area in the frontal cortex. Furthermore, in some cases of frozen gait it is difficult to distinguish between cases with white matter disorders and cases of pure akinesia on the basis of clinical symptons and CT alone. (author)

  20. Clinical study on postoperative steroid hormon replacement for preclinical Cushing's syndrome

    International Nuclear Information System (INIS)

    Furuta, Nozomu; Koide, Haruhisa; Sasaki, Hiroshi; Miki, Jun; Kimura, Takahiro; Egawa, Shin

    2009-01-01

    Diagnostic criteria for preclinical Cushing's syndrome (PCS) were reported in 1996. However, requirement of postoperative steroid hormone replacement is still controversial issue. In this study, we observed recent surgical cases retrospectively and evaluate the use of postoperative steroid hormone replacement. Eighteen patients with PCS underwent surgery from 1997 to 2007 in Jikei University Hospital. Thirteen of them received postoperative steroid hormone replacement. We investigated preoperative hormone activity by 131 I-adosterol scintigraphy and suppression of adrenocorticotropic hormone (ACTH) and evaluated the requirement of postoperative steroid hormone replacement. Preoperative serum cortisol was normal range in all patients. Serum ACTH was suppressed in 10 of them (56%). In 131 I-adosterol scintigraphy, accumulation in ipsilateral side was observed in all patients. Accumulation in contralateral side was observed in 13 patients whose serum ACTH had tendency to be suppressed. Mean period of steroid hormone replacement was 19.8 weeks. Patients with lower preoperative ACTH tended to require longer period until withdrawal of steroid hormone replacement. In addition, patients received steroid hormone replacement with higher starting dose significantly required longer period. Three of them had complications during tapering of steroid hormone. Postoperative adrenal insufficiency is important issue as postoperative management of PCS patients whose function of contralateral adrenal or pituitary gland is suppressed. 131 I-adosterol scintigraphy and preoperative serum ACTH were important factors to evaluate the requirement of postoperative steroid hormone replacement. Especially, patients with low preoperative serum ACTH tended to require long duration of postoperative steroid hormone replacement. On the other hand, patients with accumulation of contralateral side in 131 I-adosterol scintigraphy and without suppression of serum ACTH may not require steroid hormone

  1. Relationship between pre-reconstruction filter and accuracy of registration software based on mutual-information maximization. A study of SPECT-MR brain phantom images

    International Nuclear Information System (INIS)

    Mito, Suzuko; Magota, Keiichi; Arai, Hiroshi; Omote, Hidehiko; Katsuura, Hidenori; Suzuki, Kotaro; Kubo Naoki

    2005-01-01

    Image registration technique is becoming an increasingly important tool in SPECT. Recently, software based on mutual-information maximization has been developed for automatic multimodality image registration. The accuracy of the software is important for its application to image registration. During SPECT reconstruction, the projection data are pre-filtered in order to reduce Poisson noise, commonly using a Butterworth filter. We have investigated the dependence of the absolute accuracy of MRI-SPECT registration on the cut-off frequencies of a range of Butterworth filters. This study used a 3D Hoffman phantom (Model No. 9000, Data-spectrum Co.). For the reference volume, an magnetization prepared rapid gradient echo (MPRage) sequence was performed on a Vision MRI (Siemence, 1.5 T). For the floating volumes, SPECT data of a phantom including 99m Tc 85 kBq/mL were acquired by a GCA-9300 (Toshiba Medical Systems Co.). During SPECT, the orbito-meatal (OM) line of the phantom was tilted by 5 deg and 15 deg to mimic the incline of a patient's head. The projection data were pre-filtered with Butterworth filters (cut-off frequency varying between 0.24 to 0.94 cycles/cm in 0.02 steps, order 8). The automated registrations were performed using iNRT β version software (Nihon Medi. Co.) and the rotation angles of SPECT for registration were noted. In this study, the registrations of all SPECT data were successful. Graphs of registration rotation angles against cut-off frequencies were scattered and showed no correlation between the two. The registration rotation angles ranged with changing cut-off frequency from -0.4 deg to +3.8 deg at a 5 deg tilt and from +12.7 deg to +19.6 deg at a 15 deg tilt. The registration rotation angles showed variation even for slight differences in cut-off frequencies. The absolute errors were a few degrees for any cut-off frequency. Regardless of the cut-off frequency, automatic registration using this software provides similar results. (author)

  2. Synthesis of iodine-123 labelled analogues of imidazenil and ethyl-imidazenil for studying benzodiazepine receptors using SPECT

    International Nuclear Information System (INIS)

    Katsifis, A.; Mattner, F.; Dikic, B.; Najdovski, L.; Kassiou, M.

    1996-01-01

    The [ 123 I]iodinated analogues of the benzodiazepine receptor partial agonist imidazenil and N-ethyl imidazenil have been synthesised for the study of the central benzodiazepine receptor using SPECT. [ 123 I]Iodomidazenil and [ 123 I]N-ethyliodoimidazenil were prepared by nucleophilic bromine-iodine exchange in acetic acid at 150 o . The products were purified by semi-preparative reverse-phase HPLC with average radiochemical yields of 80% in a total synthesis time of 80 minutes. The specific activity was determined to be greater than 2500 Ci/mmol. The radiochemical and chemical purity assessed by radio-TLC and HPLC were found to be 98%. Alternatively, iododestannylation reactions via the trimethyltin precursors with Na[ 123 I] in the presence of Chloramine-T or peracetic acid resulted in yields of only 20-25% with the bulk of activity being lost as volatile methyl [ 123 I]iodide. (author)

  3. SPECT of the brain: Present and future

    International Nuclear Information System (INIS)

    Fazio, F.; Lenzi, G.L.

    1986-01-01

    In both PET and SPECT, most of the studies and the models have been addressed to two organs: brain and heart. So far, brain has certainly been investigated more. The several comparisons between planar scintigraphy and SPECT, between X-ray TCT and SPECT, and also between PET and SPECT, have tended to consider SPECT a cheap but scarcely useful tool for a nuclear medicine section. Again the authors feel that this is due to the fact that SPECT is really a ''physiological tomography'', with little known about its physiology or how it is measured. Thus the present state of the art of SPECT of the brain is characterized by a collection of data and reports on brain imaging and by a slowly growing basic understanding of the utilized modes. The introduction of a new brain-imaging radiopharmaceutical is immediately signaled by its ''first clinical application'' without parallel studies on the kinetics, the metabolic degradation, and the real suitability of the molecule as a tracer for measurement of regional CBF. Only a few attempts seek to narrow this discussion between clinic and biology, and the authors like to emphasize the need for nuclear medicine people to dedicate more time and effort

  4. Gated-SPECT myocardial scintigraphy in left bundle branch block: A study in patients with and without coronary artery disease

    International Nuclear Information System (INIS)

    Falcao, A.M.; Moffa, P.J.; Chalela, W.A.; Soares, J.; Oliveira, C.G.; Kreling, J.C.; Ferreira, B.A.; Uchida, A.H.; Meneghetti, J.C.

    2002-01-01

    Introduction: Myocardial perfusion scintigraphy (MPS) is a non-invasive method helpful for evaluating coronary heart disease. In left bundle branch block (LBBB), the myocardial scintigraphy frequently reveals septal abnormalities in the absence of coronary artery disease (CAD) and gives rise to 'false-positive' results in patients (pts) with suspected CAD. The purpose of this study was to assess the diagnostic role of ECG-gated SPECT in pts with complete LBBB, with and without known CAD. Methods. This study included 46 pts, 29 women (63%), with mean age 63.8 ± 11.6yr, divided into two groups: Group 1 (n=21 pts) with LBBB and CAD angiographically confirmed and Group 2 (n=25 pts) with LBBB and normal coronangiography. All pts underwent MPS at rest and two stress tests - dipyridamole (DIP) and treadmill exercise test (ET) with Bruce protocol. Myocardial perfusion, wall motility and wall thickening were analyzed qualitatively by consensus of two observers in anterior, septal, inferior, lateral and apical myocardial segments. Scores were attributed to: perfusion as normal, reversible or fixed defects; motility as normal, hypokinesia, akinesia or dyskinesia and thickening if present or absent. The left ventricle ejection fraction (LVEF) was automatically calculated from the ECG-gated SPECT. Results: The comparative analysis between groups 1 and 2 for both stresses (DIP and ET) for the parameters analyzed in the myocardial segments are presented: LVEF at rest, ET and DIP show statistically significant differences between groups 1 and 2 (p<0.0001). Conclusion: In the anterior and septal segments, only septal thickening was capable of differentiating between LBBB with and without CAD, independent of the kind of stress. In the other segments there was no influence of disturbance conduction for the perfusion analysis

  5. Contrasted study on the opening degree of blood-brain barriier after radiation therapy with SPECT and MRI

    International Nuclear Information System (INIS)

    Zhang Qing; Sun Aihua; Hu Yun; Zhang Li; Ye Hengguang

    2004-01-01

    The blood-brain barrier(BBB) is the largest barrier responsible for preventing direct contact between chemotherapeutic drugs in blood and tumors in brain, the permeability of BBB incease at different degree after brain irradiation in clinical brain tumors radiotherapy. Methods: In our study, 26 patients with metastatic brain tumors(21 cases in pr/mary lung carcinoma, 5 cases in breast carcinoma) were accepted the full brain irradiation. The detructive effects of radiation on the BBB were determined by the 99mTc-DTPA SPECT and the concentration ratio of methotrexate(MTX) in cerebrospinal fluid(CSF) and blood, the brain MRI before and after radiotherapy were retrospective contrasted study with SPECT. Results: the degree of destructive effect on the BBB was directly proportional to radiation doses. After a dose of 20Gy radiation to brain, the permeability of BBB inceased markedly(P<0.01). But in cases the dexamethasone(DXM) was administrated to decease the brain edema during radiotherapy, the permeability inceased less than that in patients without DXM(P<0.05). Conclutions: After 20Gy irradiation, the BBB would gradually open. At this time, chemotherapy is the best choice to improving the therapeutic effect. Dexamethasone was found to cause the decease in BBB permeability but no significant remission of brain edema. So, if the combination of radiotherapy and chemotherapy in treatment of metastatic brain tumors will be plan, the dexamethasone may be not used in expecting to deceasing the side effect and that no affecting the therapeutic effect. (authors)

  6. Brain SPECT in children

    International Nuclear Information System (INIS)

    Guyot, M.; Baulieu, J.L.

    1996-01-01

    Brain SPECT in child involves specific trends regarding the patient cooperation, irradiation, resolution and especially interpretation because of the rapid scintigraphic modifications related to the brain maturation. In a general nuclear medicine department, child brain SPECT represents about 2 % of the activity. The choice indications are the perfusion children: thallium and MIBI in brain tumours, pharmacological and neuropsychological interventions. In the future, brain dedicated detectors and new radiopharmaceuticals will promote the development of brain SPECT in children. (author)

  7. Clinical value of SPECT/CT in the painful total knee arthroplasty (TKA): a prospective study in a consecutive series of 100 TKA

    Energy Technology Data Exchange (ETDEWEB)

    Hirschmann, Michael T. [Kantonsspital Baselland (Bruderholz, Liestal, Laufen), Department of Orthopaedic Surgery and Traumatology, Bruderholz (Switzerland); Amsler, Felix [Amsler Consulting, Basel (Switzerland); Rasch, Helmut [Kantonsspital Baselland, Institute of Radiology and Nuclear Medicine, Bruderholz (Switzerland)

    2015-11-15

    Bone single photon emission computed tomography (SPECT)/CT is considered as beneficial in unhappy patients with pain, stiffness or swelling after total knee arthroplasty (TKA). The purpose of this study was to identify typical patterns of bone tracer uptake (BTU), distribution and intensity values in patients after TKA. The above findings were correlated with the type and fixation of TKA, the time from TKA and intraoperative findings at revision surgery. A total of 100 knees of 84 consecutive patients (mean age ± SD 70 ± 11 years) after TKA with persistent knee pain were prospectively included. All patients underwent clinical examination, standardized radiographs and {sup 99m}Tc-hydroxymethane diphosphonate (HDP) SPECT/CT as part of a routine diagnostic algorithm. The diagnosis before and after SPECT/CT and final treatment were recorded. TKA component position was determined on 3-D reconstructed images. Intensity and anatomical distribution of BTU was determined. Maximum intensity values were recorded as well as ratios in relation to the proximal midshaft of the femur. Univariate analyses (chi-square test, Pearson's correlation and t test for independent samples) were performed (p < 0.05). SPECT/CT changed the clinical diagnosis and final treatment in 85/100 (85 %) knees. Intraoperative findings confirmed the preoperative SPECT/CT diagnosis in 32/33 knees (97 %). TKA loosening as well as progression of patellofemoral osteoarthritis (OA) was correctly diagnosed in 100 % of knees. Typical patterns of BTU for specific pathologies were identified. Loose femoral TKA components significantly correlated with increased BTU at the lateral femoral regions (p < 0.05). Loose tibial TKA components significantly correlated with increased BTU at all tibial regions (p < 0.05) and around the tibial peg (p > 0.01). The diagnostic benefits of SPECT/CT in patients after TKA have been proven. Typical pathology-related BTU patterns were identified, which will improve reporting

  8. Clinical value of SPECT/CT in the painful total knee arthroplasty (TKA): a prospective study in a consecutive series of 100 TKA

    International Nuclear Information System (INIS)

    Hirschmann, Michael T.; Amsler, Felix; Rasch, Helmut

    2015-01-01

    Bone single photon emission computed tomography (SPECT)/CT is considered as beneficial in unhappy patients with pain, stiffness or swelling after total knee arthroplasty (TKA). The purpose of this study was to identify typical patterns of bone tracer uptake (BTU), distribution and intensity values in patients after TKA. The above findings were correlated with the type and fixation of TKA, the time from TKA and intraoperative findings at revision surgery. A total of 100 knees of 84 consecutive patients (mean age ± SD 70 ± 11 years) after TKA with persistent knee pain were prospectively included. All patients underwent clinical examination, standardized radiographs and 99m Tc-hydroxymethane diphosphonate (HDP) SPECT/CT as part of a routine diagnostic algorithm. The diagnosis before and after SPECT/CT and final treatment were recorded. TKA component position was determined on 3-D reconstructed images. Intensity and anatomical distribution of BTU was determined. Maximum intensity values were recorded as well as ratios in relation to the proximal midshaft of the femur. Univariate analyses (chi-square test, Pearson's correlation and t test for independent samples) were performed (p < 0.05). SPECT/CT changed the clinical diagnosis and final treatment in 85/100 (85 %) knees. Intraoperative findings confirmed the preoperative SPECT/CT diagnosis in 32/33 knees (97 %). TKA loosening as well as progression of patellofemoral osteoarthritis (OA) was correctly diagnosed in 100 % of knees. Typical patterns of BTU for specific pathologies were identified. Loose femoral TKA components significantly correlated with increased BTU at the lateral femoral regions (p < 0.05). Loose tibial TKA components significantly correlated with increased BTU at all tibial regions (p < 0.05) and around the tibial peg (p > 0.01). The diagnostic benefits of SPECT/CT in patients after TKA have been proven. Typical pathology-related BTU patterns were identified, which will improve reporting quality

  9. SPECT/CT imaging in children with papillary thyroid carcinoma

    International Nuclear Information System (INIS)

    Kim, Hwa-Young; Gelfand, Michael J.; Sharp, Susan E.

    2011-01-01

    SPECT/CT improves localization of single photon-emitting radiopharmaceuticals. To determine the utility of SPECT/CT in children with papillary thyroid carcinoma. 20 SPECT/CT and planar studies were reviewed in 13 children with papillary thyroid carcinoma after total thyroidectomy. Seven studies used I-123 and 13 used I-131, after elevating TSH by T4 deprivation or intramuscular thyrotropin alfa. Eight children had one study and five children had two to four studies. Studies were performed at initial post-total thyroidectomy evaluation, follow-up and after I-131 treatment doses. SPECT/CT was performed with a diagnostic-quality CT unit in 13 studies and a localization-only CT unit in 7. Stimulated thyroglobulin was measured (except in 2 cases with anti-thyroglobulin antibodies). In 13 studies, neck activity was present but poorly localized on planar imaging; all foci of uptake were precisely localized by SPECT/CT. Two additional foci of neck uptake were found on SPECT/CT. SPECT/CT differentiated high neck uptake from facial activity. In six studies (four children), neck uptake was identified as benign by SPECT/CT (three thyroglossal duct remnants, one skin contamination, two by precise anatomical CT localization). In two children, SPECT/CT supported a decision not to treat with I-131. When SPECT/CT was unable to identify focal uptake as benign, stimulated thyroglobulin measurements were valuable. In three of 13 studies with neck uptake, SPECT/CT provided no useful additional information. SPECT/CT precisely localizes neck iodine uptake. In small numbers of patients, treatment is affected. SPECT/CT should be used when available in thyroid carcinoma patients. (orig.)

  10. Contralateral thalamic hypoperfusion on brain perfusion SPECT

    International Nuclear Information System (INIS)

    Lee, Seok Mo; Bae, Sang Kyun; Yoo, Kyung Moo; Yum, Ha Yong

    2000-01-01

    Brain perfusion single photon emission computed tomography (SPECT) is useful for the localization of cerebrovascular lesion and sometimes reveals more definite lesion than radiologic imaging modality such as CT or MRI does. The purpose of this study was to evaluate the diagnostic usefulness of brain perfusion SPECT in patients with hemisensory impairment. Thirteen consecutive patients (M:F= 8:5, mean age = 48) who has hemisensory impairment were included. Brain perfusion SPECT was performed after intravenous injection of 1110 MBq of Tc-99m ECD. The images were obtained using a dual-head gamma camera with ultra-high resolution collimator. Semiquantitative analysis was performed after placing multiple ROIs on cerebral cortex, basal ganglia, thalamus and cerebellum. There were 10 patients with left hemisensory impairment and 3 patients with right-sided symptom. Only 2 patients revealed abnormal signal change in the thalamus on MRI. But brain perfusion SPECT showed decreased perfusion in the thalamus in 9 patients. Six patients among 10 patients with left hemisensory impairment revealed decreased perfusion in the contralateral thalamus on brain SPECT. The other 4 patients revealed no abnormality. Two patients among 3 patients with right hemisensory impairment also showed decreased perfusion in the contralateral thalamus on brain SPECT. One patients with right hemisensory impairment showed ipsilateral perfusion decrease. Two patients who had follow-up brain perfusion SEPCT after treatment revealed normalization of perfusion in the thalamus. Brain perfusion SPECT might be a useful tool in diagnosing patients with hemisensory impairment

  11. Mechanism study of recovery from aphasia with 99Tcm-ECD SPECT brain imaging after oral reading test

    International Nuclear Information System (INIS)

    Chen Jian; Xu Hao; Wang Hong; Chen Zhuoming; Wu Qiulian

    2007-01-01

    Objective: There may be two mechanisms for recovery from aphasia----repair of dam- aged left hemisphere language network and(or) activation of compensatory areas in right hemisphere. It is, however, still controversial on which mechanism plays a more important role. The goal of this study was to compare the regional cerebral blood flow (rCBF) between baseline and during oral reading in aphasic patients who had shown definite recovery from a focal lesion in left hemisphere. It also aimed at exploring the role of the two hemispheres in recovery from aphasia, thus providing theoretic basis for rehabilitation therapy. Methods: Baseline and oral reading 99 Tc m -ethylcysteinate dimer (ECD) brain SPECT imaging were performed in 7 patients with aphasia separately in one-day interval. Semi-quantitative analysis of rCBF was conducted on 26 symmetrical ROIs in bilateral hemispheres on the transverse slices. The rCBF was estimated by the ratio of the counts per pixel of each ROI to the average counts per pixel of the whole encephalon. The change in blood flow was represented by the difference in rCBF between oral reading and baseline. Results: The activated perfusion pattern of brain region was different in all 7 aphasic patients. In 5 of the 7 patients, whose reading capacity were relatively preserved, the brain perfusion pattern was mainly left lateralized, while the other two patients who had poor performance in reading showed bilateral activation foci with fight-sided dominance. Conclusion: Oral reading activated SPECT brain imaging may be a useful tool for monitoring the progress of speech recovery in the treatment of aphasic patients. (authors)

  12. Preclinical safety, pharmacokinetics, pharmacodynamics, and biodistribution studies with Ad35K++ protein: a novel rituximab cotherapeutic

    Directory of Open Access Journals (Sweden)

    Maximilian Richter

    2016-01-01

    Full Text Available Rituximab is a mouse/human chimeric monoclonal antibody targeted toward CD20. It is efficient as first-line therapy of CD20-positive B-cell malignancies. However, a large fraction of treated patients relapse with rituximab-resistant disease. So far, only modest progress has been made in treatment options for rituximab refractory patients. One of the mechanisms for rituximab resistance involves the upregulation of CD46, which is a key cell surface protein that blocks the activation of complement. We have recently developed a technology that depletes CD46 from the cell surface and thereby sensitizes tumor cells to complement-dependent cytotoxicity. This technology is based on a small recombinant protein, Ad35K++ that binds with high affinity to CD46. In preliminary studies using a 6 × histidinyl tagged protein, we had demonstrated that intravenous Ad35K++ injection in combination with rituximab was safe and increased rituximab-mediated killing of CD20-positive target cells in mice and nonhuman primates (NHPs. The presence of the tag, while allowing for easy purification by Ni-NTA chromatography, has the potential to increase the immunogenicity of the recombinant protein. For clinical application, we therefore developed an Ad35K++ protein without His-tag. In the present study, we performed preclinical studies in two animal species (mice and NHPs with this protein demonstrating its safety and efficacy. These studies estimated the Ad35K++ dose range and treatment regimen to be used in patients. Furthermore, we showed that intravenous Ad35K++ injection triggers the shedding of the CD46 extracellular domain in xenograft mouse tumor models and in macaques. Shed serum CD46 can be measured in the serum and can potentially be used as a pharmacodynamic marker for monitoring Ad35K++ activity in patient undergoing treatment with this agent. These studies create the basis for an investigational new drug application for the use of Ad35K++ in combination with

  13. In question: the scientific value of preclinical safety pharmacology and toxicology studies with cell-based therapies

    Directory of Open Access Journals (Sweden)

    Christiane Broichhausen

    2014-01-01

    Full Text Available A new cell-based medicinal product containing human regulatory macrophages, known as Mreg_UKR, has been developed and conforms to expectations of a therapeutic drug. Here, Mreg_UKR was subjected to pharmacokinetic, safety pharmacology, and toxicological testing, which identified no adverse reactions. These results would normally be interpreted as evidence of the probable clinical safety of Mreg_UKR; however, we contend that, owing to their uncertain biological relevance, our data do not fully support this conclusion. This leads us to question whether there is adequate scientific justification for preclinical safety testing of similar novel cell-based medicinal products using animal models. In earlier work, two patients were treated with regulatory macrophages prior to kidney transplantation. In our opinion, the absence of acute or chronic adverse effects in these cases is the most convincing available evidence of the likely safety of Mreg_UKR in future recipients. On this basis, we consider that safety information from previous clinical investigations of related cell products should carry greater weight than preclinical data when evaluating the safety profile of novel cell-based medicinal products. By extension, we argue that omitting extensive preclinical safety studies before conducting small-scale exploratory clinical investigations of novel cell-based medicinal products data may be justifiable in some instances.

  14. Sex differences in the vulnerability to drug abuse: a review of preclinical studies.

    Science.gov (United States)

    Roth, Megan E; Cosgrove, Kelly P; Carroll, Marilyn E

    2004-10-01

    Clinical and preclinical findings indicate that males and females differ on several aspects of drug reinforcement. Females are more vulnerable than males during transition periods of drug use that are characteristic of drug addiction and relapse. Females are also more sensitive than males to the reinforcing effects of stimulants. It has been suggested that ovarian hormones contribute to the mechanisms of action underlying these sex differences. This review examines the preclinical literature on sex differences and ovarian hormonal influences on drug self-administration in animals. It summarizes the findings on the effects of these variables during different phases of drug addiction. Possible differences in the mechanisms of action of drugs of abuse due to interactions with sex differences or ovarian hormonal factors are considered. The animal literature on sex differences in drug abuse treatment effectiveness is also discussed.

  15. Stem Cells for Cartilage Repair: Preclinical Studies and Insights in Translational Animal Models and Outcome Measures

    OpenAIRE

    Lo Monaco, Melissa; Merckx, Greet; Ratajczak, Jessica; Gervois, Pascal; Hilkens, Petra; Clegg, Peter; Bronckaers, Annelies; Vandeweerd, Jean-Michel; Lambrichts, Ivo

    2018-01-01

    Due to the restricted intrinsic capacity of resident chondrocytes to regenerate the lost cartilage postinjury, stem cell-based therapies have been proposed as a novel therapeutic approach for cartilage repair. Moreover, stem cell-based therapies using mesenchymal stem cells (MSCs) or induced pluripotent stem cells (iPSCs) have been used successfully in preclinical and clinical settings. Despite these promising reports, the exact mechanisms underlying stem cell-mediated cartilage repair remain...

  16. Impact of diet restriction in the management of diabetes: evidences from preclinical studies.

    Science.gov (United States)

    Krishan, Pawan; Bedi, Onkar; Rani, Monika

    2018-03-01

    The inappropriate dietary habits lead to the onset of age-related pathologies which include diabetes and cardiovascular ailments. Dietary restriction and nutritional therapy play an important role in the prevention of these chronic ailments. Preclinical research provides a basis for the therapeutic exploration of new dietary interventions for the clinical trials to potentiate the scientific management of diabetes and its related complications which further help in translating these nutritional improvements from bench to bedside. Within the same context, numerous therapeutically proved preclinical dietary interventions like high-fiber diet, caloric restriction, soy isoflavone-containing diets, etc., have shown the promising results for the management of diabetes and the associated complications. The focus of the present review is to highlight the various preclinical evidences of diet restriction for the management of diabetes and which will be helpful for enlightening the new ideas of nutritional therapy for future research exploration. In addition, some potential approaches are also discussed which are associated with various nutritional interventions to combat progressive diabetes and the associated disorders. Graphical abstract ᅟ.

  17. Evaluation of focused multipolar stimulation for cochlear implants: a preclinical safety study

    Science.gov (United States)

    Shepherd, Robert K.; Wise, Andrew K.; Enke, Ya Lang; Carter, Paul M.; Fallon, James B.

    2017-08-01

    Objective. Cochlear implants (CIs) have a limited number of independent stimulation channels due to the highly conductive nature of the fluid-filled cochlea. Attempts to develop highly focused stimulation to improve speech perception in CI users includes the use of simultaneous stimulation via multiple current sources. Focused multipolar (FMP) stimulation is an example of this approach and has been shown to reduce interaction between stimulating channels. However, compared with conventional biphasic current pulses generated from a single current source, FMP is a complex stimulus that includes extended periods of stimulation before charge recovery is achieved, raising questions on whether chronic stimulation with this strategy is safe. The present study evaluated the long-term safety of intracochlear stimulation using FMP in a preclinical animal model of profound deafness. Approach. Six cats were bilaterally implanted with scala tympani electrode arrays two months after deafening, and received continuous unilateral FMP stimulation at levels that evoked a behavioural response for periods of up to 182 d. Electrode impedance, electrically-evoked compound action potentials (ECAPs) and auditory brainstem responses (EABRs) were monitored periodically over the course of the stimulation program from both the stimulated and contralateral control cochleae. On completion of the stimulation program cochleae were examined histologically and the electrode arrays were evaluated for evidence of platinum (Pt) corrosion. Main results. There was no significant difference in electrode impedance between control and chronically stimulated electrodes following long-term FMP stimulation. Moreover, there was no significant difference between ECAP and EABR thresholds evoked from control or stimulated cochleae at either the onset of stimulation or at completion of the stimulation program. Chronic FMP stimulation had no effect on spiral ganglion neuron (SGN) survival when compared with

  18. Improving gastric cancer preclinical studies using diverse in vitro and in vivo model systems

    International Nuclear Information System (INIS)

    Chang, Hae Ryung; Park, Hee Seo; Ahn, Young Zoo; Nam, Seungyoon; Jung, Hae Rim; Park, Sungjin; Lee, Sang Jin; Balch, Curt; Powis, Garth; Ku, Ja-Lok; Kim, Yon Hui

    2016-01-01

    “Biomarker-driven targeted therapy,” the practice of tailoring patients’ treatment to the expression/activity levels of disease-specific genes/proteins, remains challenging. For example, while the anti-ERBB2 monoclonal antibody, trastuzumab, was first developed using well-characterized, diverse in vitro breast cancer models (and is now a standard adjuvant therapy for ERBB2-positive breast cancer patients), trastuzumab approval for ERBB2-positive gastric cancer was largely based on preclinical studies of a single cell line, NCI-N87. Ensuing clinical trials revealed only modest patient efficacy, and many ERBB2-positive gastric cancer (GC) patients failed to respond at all (i.e., were inherently recalcitrant), or succumbed to acquired resistance. To assess mechanisms underlying GC insensitivity to ERBB2 therapies, we established a diverse panel of GC cells, differing in ERBB2 expression levels, for comprehensive in vitro and in vivo characterization. For higher throughput assays of ERBB2 DNA and protein levels, we compared the concordance of various laboratory quantification methods, including those of in vitro and in vivo genetic anomalies (FISH and SISH) and xenograft protein expression (Western blot vs. IHC), of both cell and xenograft (tissue-sectioned) microarrays. The biomarker assessment methods strongly agreed, as did correlation between RNA and protein expression. However, although ERBB2 genomic anomalies showed good in vitro vs. in vivo correlation, we observed striking differences in protein expression between cultured cells and mouse xenografts (even within the same GC cell type). Via our unique pathway analysis, we delineated a signaling network, in addition to specific pathways/biological processes, emanating from the ERBB2 signaling cascade, as a potential useful target of clinical treatment. Integrated analysis of public data from gastric tumors revealed frequent (10 – 20 %) amplification of the genes NFKBIE, PTK2, and PIK3CA, each of which

  19. Dementia, preclinical studies in neurodegeneration and its potential for translational medicine in SouthAmerica

    Directory of Open Access Journals (Sweden)

    Gloria Patricia Cardona Gomez

    2016-12-01

    Full Text Available Latin-American people with dementia will increase in a 368% in 2050, higher than USA and Europe. In addition, to sporadic dementia type Alzheimer and vascular dementia progression after Cerebrovascular disease, the statistics are increased in Colombia by specific populations affected with pure neurodegenerative and vascular dementias like autosomical dominant familial Alzheimer´s disease and CADASIL. In spite of the enormous human and economical effort and investment, neither sporadic nor genetic kinds of dementia progression have been prevented or blocked yet. Currently, exist several animal models that partially solve the understanding of the neurodegenerative etiopathogenesis and its treatment. However, when the potential therapies are translated to humans, those do not work or present a limited action. Main difficulties are the diverse comorbility associated to the cause and/or several affected brain regions, reducing the efficacy of some therapies which are limited to a tissue-specific action or modulating a kind of neurotransmission. Global investigation suggests that a general prevention could be achieved with the improvement in the quality of lifestyle, including healthy diet, physical and mental activity, and avoiding mechanical or chemical pro-inflammatory events in an early stage in the most of non-communicable diseases. In this review, we present some molecular targets and preclinical studies in animal models to propose strategies that could be useful in a future translation to prevent or block neurodegeneration: One is gene therapy silencing pathogenic genes in critical brain areas where excitotoxicity arise and spread. Another is to take advantage of the natural source and its wide biodiversity of natural products some of them identified by the blocking and prevention of neurodegeneration. On the other side, the casuistic of pure dementias in the Latin-American region give an exceptional opportunity to understand the pathogenesis

  20. Study on localization diagnosis with SPECT rCBF image in childhood epilepsy: in comparison with EEG and MRI findings

    International Nuclear Information System (INIS)

    Wu Meiqian; Tang Jihong; Wu Jinchang; Shi Yizhen

    1999-01-01

    Objective: To evaluate the diagnostic value of SPECT rCBF imaging in localization of childhood epileptic foci. Methods: rCBF imaging was performed in 74 epileptic patients not in seizure and 10 epileptic patients right in seizure. EEG was performed in 84, MRI in 67 of the subjects mentioned above. All the results of three modalities were compared with each other. Results: The highest positive rate (82.14%) was found in SPECT rCBF imaging, the positive rate in EEG or MRI was 71.43 or 47.76%. The epileptic foci localized by EEG (60 abnormalities) and by MRI (32 abnormalities) were 70.59% or 58.82% in concordance with those by SPECT, respectively. Conclusions: SPECT rCBF imaging is a sensitive and effective method for epileptic foci localization. It may have some advantages over EEG and MRI in detecting and localizing epileptic foci. However, abnormal SPECT areas may cover some abnormalities which do not belong to epileptic category. A combination of these three methods (SPECT, EEG and MRI) will improve the positive rate and accuracy for localizing

  1. Brain SPECT imaging in temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Krausz, Y.; Yaffe, S.; Atlan, H.; Cohen, D.; Konstantini, S.; Meiner, Z.

    1991-01-01

    Temporal lobe epilepsy is diagnosed by clinical symptoms and signs and by localization of an epileptogenic focus. A brain SPECT study of two patients with temporal lobe epilepsy, using 99m Tc-HMPAO, was used to demonstrate a perfusion abnormality in the temporal lobe, while brain CT and MRI were non-contributory. The electroencephalogram, though abnormal, did not localize the diseased area. The potential role of the SPECT study in diagnosis and localization of temporal lobe epilepsy is discussed. (orig.)

  2. Slowly progressive fluent aphasia; Clinical features and an imaging study including MRI, SPECT and PET

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Yasuhisa; Momose, Toshimitsu; Watanabe, Toshiaki; Ishikawa, Takashi; Iwata, Makoto (Tokyo Univ. (Japan). Faculty of Medicine); Bando, Mitsuaki

    1991-05-01

    Three patients with slowly progressive fluent aphasia are reported. One of the patients presented with memory disturbance. They were characterized clinically by having selective deficits in vocabulary, which resulted in impairment of confrontation naming, and auditory comprehension. MRI showed an atrophy not only in the left temporal lobe (including the superior, middle and inferior temporal gyri), hippocampus, parahippocampual gyrus, and fusiform gyrus, but also in the left parietal lobe. I-123 IMP SPECT and F-18 FDG PET were used to determine regional cerebral blood flow and regional cerebral metabolic rate, respectively. In addition to the decreased tracer uptake in the left temporal and/or parietal lobe, a decreased uptake was seen in the bilateral basal ganglia, the inner side of the temporal lobe (including the bilateral hippocampus), the right anterior temporal lobe, and the left thalamus. These findings may deny the previous thought that lesions are localized in slowly progressive fluent aphasia. Furthermore, noticeable difficulty in naming, i.e., patients unable to recognize the right answer, are considered attributable to widespread lesions from the whole left temporal lobe, including the hippocampus, to the right temporal lobe. (N.K.).

  3. A study of reconstruction accuracy for a cardiac SPECT system with multi-segmental collimation

    International Nuclear Information System (INIS)

    Yu, D.C.; Chang, W.; Pan, T.S.

    1996-01-01

    To improve the geometric efficiency of cardiac SPECT imaging, we have previously proposed to use a ring geometry and a multi-segmental collimation. The proposed collimation consists of multiple parallel collimators with most of the segments focused on a small central region, where the patient heart should be positioned. This scheme provides an significantly increased detection efficiency for the central region, but at the expense of reduced efficiency for the surrounding background. We have used computer simulations to evaluate the implication of this scheme on the accuracy of the reconstructed cardiac images. Two imaging situations were simulated, one with the heart well placed in the center, the other with the heart shifted outward and partially outside the central region; a neighboring high uptake liver was also simulated. The images were reconstructed with ML-EM and OS-EM methods using a complete attenuation map. The results indicate the deviation caused by truncation is not significant and is not strongly dependent on the activity of the liver when the heart is well positioned within the central region. The distribution of activity in the myocardium reconstructed with ML-EM or OS-EM is not sensitive to the noisy projections sampled from the background. When the heart is positioned improperly, the image reconstructed from the hybrid emission (a combination of high-count projections through the central region and low-count background projections) can restore the activity for the myocardium with increased noise variances in the section outside the central region

  4. Experimental determination of the weighting factor for the energy window subtraction-based downscatter correction for I-123 in brain SPECT studies

    DEFF Research Database (Denmark)

    de Nijs, Robin; Holm, Søren; Thomsen, Gerda

    2010-01-01

    Correction for downscatter in I-123 SPECT can be performed by the subtraction of a secondary energy window from the main window, as in the triple-energy window method. This is potentially noise sensitive. For studies with limited amount of counts (e.g. dynamic studies), a broad subtraction window...... were investigated in this study. Energy windows with a width of 32 keV were centered at 159 keV and 200 keV. The weighting factor was measured both with an I-123 point source and in a dopamine transporter brain SPECT study in 10 human subjects (5 healthy subjects and 5 patients) by minimizing...... the background outside the head. Weighting factors ranged from 1.11 to 1.13 for the point source and from 1.16 to 1.18 for human subjects. Point source measurements revealed no position dependence. After correction, the measured specific binding ratio (image contrast) increased significantly for healthy subjects...

  5. Evaluation of image reconstruction methods for {sup 123}I-MIBG-SPECT. A rank-order study

    Energy Technology Data Exchange (ETDEWEB)

    Soederberg, Marcus; Mattsson, Soeren; Oddstig, Jenny; Uusijaervi-Lizana, Helena; Leide-Svegborn, Sigrid [Medical Radiation Physics, Dept. of Clinical Sciences Malmoe, Lund Univ., Skaane Univ. Hospital, Malmoe (Sweden)], e-mail: marcus.soderberg@med.lu.se; Valind, Sven; Thorsson, Ola; Garpered, Sabine [Dept. of Clinical Physiology, Skaane Univ. Hospital, Malmoe (Sweden); Prautzsch, Tilmann [Scivis wissenschaftlice Bildverarbeitung GmbH, Goettingen (Germany); Tischenko, Oleg [Research Unit Medical Radiation Physics and Diagnostics (AMSD), Helmholtz Zentrum Muenchen (Germany); German Research Center for Environmental Health, Neuherberg (Germany)

    2012-09-15

    Background: There is an opportunity to improve the image quality and lesion detectability in single photon emission computed tomography (SPECT) by choosing an appropriate reconstruction method and optimal parameters for the reconstruction. Purpose: To optimize the use of the Flash 3D reconstruction algorithm in terms of equivalent iteration (EI) number (number of subsets times the number of iterations) and to compare with two recently developed reconstruction algorithms ReSPECT and orthogonal polynomial expansion on disc (OPED) for application on {sup 123}I-metaiodobenzylguanidine (MIBG)-SPECT. Material and Methods: Eleven adult patients underwent SPECT 4 h and 14 patients 24 h after injection of approximately 200 MBq {sup 123}I-MIBG using a Siemens Symbia T6 SPECT/CT. Images were reconstructed from raw data using the Flash 3D algorithm at eight different EI numbers. The images were ranked by three experienced nuclear medicine physicians according to their overall impression of the image quality. The obtained optimal images were then compared in one further visual comparison with images reconstructed using the ReSPECT and OPED algorithms. Results: The optimal EI number for Flash 3D was determined to be 32 for acquisition 4 h and 24 h after injection. The average rank order (best first) for the different reconstructions for acquisition after 4 h was: Flash 3D{sub 32} > ReSPECT > Flash 3D{sub 64} > OPED, and after 24 h: Flash 3D{sub 16} > ReSPECT > Flash 3D{sub 32} > OPED. A fair level of inter-observer agreement concerning optimal EI number and reconstruction algorithm was obtained, which may be explained by the different individual preferences of what is appropriate image quality. Conclusion: Using Siemens Symbia T6 SPECT/CT and specified acquisition parameters, Flash 3D{sub 32} (4 h) and Flash 3D{sub 16} (24 h), followed by ReSPECT, were assessed to be the preferable reconstruction algorithms in visual assessment of {sup 123}I-MIBG images.

  6. Questionnaire survey of SPECT studies after the supply shortage of Tc-99m and model analysis concerning earnings and expenditure of generator use

    International Nuclear Information System (INIS)

    Kinoshita, Ryo; Kosuda, Shigeru; Koike, Katsumi; Arai, Takashi

    2012-01-01

    A questionnaire survey was conducted to evaluate decrease in SPECT studies and its causes after the cessation of long supply shortage of 99 Mo/ 99 mTc generators. Of the replies by the chief nuclear medicine technologists, no necessity for 99 Mo/ 99 mTc generator use or for domestic supply of 99 mTc unexpectedly accounted for 25% and 46%, respectively. Generator use leads to an additional profit by 8654 yen per patient, compared to purchase of commercially available 99 mTc-labeled kits. It is essential to install a 99 Mo/ 99 mTc generator to perform emergency SPECT studies, increase a profit in hospital management, reduction of financial issues in patients, and pediatric studies. This adverse circumstance, however, may provide a good opportunity to instruct nuclear medicine specialists to be aware of the importance mentioned above in medical meetings. (author)

  7. Evaluation of Efficacy of Bone Scan With SPECT/CT in the Management of Low Back Pain: A Study Supported by Differential Diagnostic Local Anesthetic Blocks.

    Science.gov (United States)

    Jain, Anuj; Jain, Suruchi; Agarwal, Anil; Gambhir, Sanjay; Shamshery, Chetna; Agarwal, Amita

    2015-12-01

    Conventional radiologic modalities provide details only about the anatomic aspect of the various structures of the spine. Frequently the structures that show abnormal morphology may not be the cause of low back pain (LBP). Functional imaging in the form of bone scan along with single photon emission computerized tomography (SPECT/CT) may be helpful in identifying structures causing pain, whether morphologically normal or not. The objective of this study is to evaluate the role of bone scan with SPECT/CT in management of patients with LBP. This is randomized double-blinded controlled study performed on 80 patients with LBP aged 20 to 80 years, ASA physical status I to III. Patients were randomized into bone scan and control groups consisting of 40 patients each. On the basis of the clinical features and radiologic findings a clinical diagnosis was made. After making a clinical diagnosis, the patients in bone scan group were subjected to bone scan with SPECT/CT. On the basis of the finding of the bone scan and SPECT/CT, a new working diagnosis was made and intervention was performed according to the new working diagnosis. Diagnostic blocks in the control group were given based on clinical diagnosis. Controlled comparative diagnostic blocks were performed with local anesthetic. The pain score just after the diagnostic block and at the time of discharge (approximately 4 h later) was recorded; the pain relief was recorded in percentage. In both the groups, sacroilitis was the most common diagnosis followed by facet joint arthropathy. The number of patients obtaining pain relief of >50% was significantly higher in the bone scan-positive group as compared with the control group. Three new clinical conditions were identified in the bone scan group. These conditions were multiple myeloma, avascular necrosis of the femoral head, and ankylosing spondylitis. Bone scan with SPECT/CT was found to complement the clinical workup of patients with LBP. Inclusion of bone scan with

  8. Preclinical studies of lymphographic applilcation of 99mTc-dextrans of different molecular weight

    International Nuclear Information System (INIS)

    Lamka, J.; Kvetina, J.; Kafka, P.

    1986-01-01

    In a preclinical investigation on rabbits the distribution was tested of dextrans of two molecular weights (40,000 and 70,000) with regard to their use as a carrier in indirect lymphography. The tests showed that both 99m Tc-dextrans achieve high ratios of lymph/blood levels. It is suggested that for clinical work it is better to use dextran with a molecular weight of 70,000 than that with a molecular weight of 40,000. (author)

  9. Insights From Pre-Clinical and Clinical Studies on the Role of Innate Inflammation in Atherosclerosis Regression

    Directory of Open Access Journals (Sweden)

    Karishma Rahman

    2018-05-01

    Full Text Available Atherosclerosis, the underlying cause of coronary artery (CAD and other cardiovascular diseases, is initiated by macrophage-mediated immune responses to lipoprotein and cholesterol accumulation in artery walls, which result in the formation of plaques. Unlike at other sites of inflammation, the immune response becomes maladaptive and inflammation fails to resolve. The most common treatment for reducing the risk from atherosclerosis is low density lipoprotein cholesterol (LDL-C lowering. Studies have shown, however, that while significant lowering of LDL-C reduces the risk of heart attacks to some degree, there is still residual risk for the majority of the population. We and others have observed “residual inflammatory risk” of atherosclerosis after plasma cholesterol lowering in pre-clinical studies, and that this phenomenon is clinically relevant has been dramatically reinforced by the recent Canakinumab Anti-inflammatory Thrombosis Outcomes Study (CANTOS trial. This review will summarize the role of the innate immune system, specifically macrophages, in atherosclerosis progression and regression, as well as the pre-clinical and clinical models that have provided significant insights into molecular pathways involved in the resolution of plaque inflammation and plaque regression. Partnered with clinical studies that can be envisioned in the post-CANTOS period, including progress in developing targeted plaque therapies, we expect that pre-clinical studies advancing on the path summarized in this review, already revealing key mechanisms, will continue to be essential contributors to achieve the goals of dampening plaque inflammation and inducing its resolution in order to maximize the therapeutic benefits of conventional risk factor modifications, such as LDL-C lowering.

  10. Comparative Plasma Exposure and Lung Distribution of Two Human Use Commercial Azithromycin Formulations Assessed in Murine Model: A Preclinical Study

    OpenAIRE

    Rivulgo, Virginia Margarita; Sparo, Mónica; Ceci, Mónica; Fumuso, Elida; Confalonieri, Alejandra; Delpech, Gastón; Sanchez Bruni, Sergio Fabian

    2016-01-01

    Azithromycin(AZM)therapeutic failure and relapses of patients treated with generic -35 formulations have been observed in clinical practice.The main goal of this research was 36 to compare in a pre-clinical study the serum exposure and lung tissue concentrationof 37 two commercial formulations AZM-based in murine model. The current study involved 38 264 healthy Balb-C.Mice were divided in two groups (n=44): Animals of Group A 39 (Reference Formulation ?R-) were orally treated with AZM suspens...

  11. A quantitative analysis of statistical power identifies obesity end points for improved in vivo preclinical study design.

    Science.gov (United States)

    Selimkhanov, J; Thompson, W C; Guo, J; Hall, K D; Musante, C J

    2017-08-01

    The design of well-powered in vivo preclinical studies is a key element in building the knowledge of disease physiology for the purpose of identifying and effectively testing potential antiobesity drug targets. However, as a result of the complexity of the obese phenotype, there is limited understanding of the variability within and between study animals of macroscopic end points such as food intake and body composition. This, combined with limitations inherent in the measurement of certain end points, presents challenges to study design that can have significant consequences for an antiobesity program. Here, we analyze a large, longitudinal study of mouse food intake and body composition during diet perturbation to quantify the variability and interaction of the key metabolic end points. To demonstrate how conclusions can change as a function of study size, we show that a simulated preclinical study properly powered for one end point may lead to false conclusions based on secondary end points. We then propose the guidelines for end point selection and study size estimation under different conditions to facilitate proper power calculation for a more successful in vivo study design.

  12. Threats to validity in the design and conduct of preclinical efficacy studies: a systematic review of guidelines for in vivo animal experiments.

    Directory of Open Access Journals (Sweden)

    Valerie C Henderson

    Full Text Available The vast majority of medical interventions introduced into clinical development prove unsafe or ineffective. One prominent explanation for the dismal success rate is flawed preclinical research. We conducted a systematic review of preclinical research guidelines and organized recommendations according to the type of validity threat (internal, construct, or external or programmatic research activity they primarily address.We searched MEDLINE, Google Scholar, Google, and the EQUATOR Network website for all preclinical guideline documents published up to April 9, 2013 that addressed the design and conduct of in vivo animal experiments aimed at supporting clinical translation. To be eligible, documents had to provide guidance on the design or execution of preclinical animal experiments and represent the aggregated consensus of four or more investigators. Data from included guidelines were independently extracted by two individuals for discrete recommendations on the design and implementation of preclinical efficacy studies. These recommendations were then organized according to the type of validity threat they addressed. A total of 2,029 citations were identified through our search strategy. From these, we identified 26 guidelines that met our eligibility criteria--most of which were directed at neurological or cerebrovascular drug development. Together, these guidelines offered 55 different recommendations. Some of the most common recommendations included performance of a power calculation to determine sample size, randomized treatment allocation, and characterization of disease phenotype in the animal model prior to experimentation.By identifying the most recurrent recommendations among preclinical guidelines, we provide a starting point for developing preclinical guidelines in other disease domains. We also provide a basis for the study and evaluation of preclinical research practice. Please see later in the article for the Editors' Summary.

  13. Threats to validity in the design and conduct of preclinical efficacy studies: a systematic review of guidelines for in vivo animal experiments.

    Science.gov (United States)

    Henderson, Valerie C; Kimmelman, Jonathan; Fergusson, Dean; Grimshaw, Jeremy M; Hackam, Dan G

    2013-01-01

    The vast majority of medical interventions introduced into clinical development prove unsafe or ineffective. One prominent explanation for the dismal success rate is flawed preclinical research. We conducted a systematic review of preclinical research guidelines and organized recommendations according to the type of validity threat (internal, construct, or external) or programmatic research activity they primarily address. We searched MEDLINE, Google Scholar, Google, and the EQUATOR Network website for all preclinical guideline documents published up to April 9, 2013 that addressed the design and conduct of in vivo animal experiments aimed at supporting clinical translation. To be eligible, documents had to provide guidance on the design or execution of preclinical animal experiments and represent the aggregated consensus of four or more investigators. Data from included guidelines were independently extracted by two individuals for discrete recommendations on the design and implementation of preclinical efficacy studies. These recommendations were then organized according to the type of validity threat they addressed. A total of 2,029 citations were identified through our search strategy. From these, we identified 26 guidelines that met our eligibility criteria--most of which were directed at neurological or cerebrovascular drug development. Together, these guidelines offered 55 different recommendations. Some of the most common recommendations included performance of a power calculation to determine sample size, randomized treatment allocation, and characterization of disease phenotype in the animal model prior to experimentation. By identifying the most recurrent recommendations among preclinical guidelines, we provide a starting point for developing preclinical guidelines in other disease domains. We also provide a basis for the study and evaluation of preclinical research practice. Please see later in the article for the Editors' Summary.

  14. Quantitative gated SPECT- a comparative study of two algorithms for parameters of perfusion and LV function

    International Nuclear Information System (INIS)

    Ali, A.Z.

    2007-01-01

    Full text: Aim: To compare the perfusion and LV function parameters as quantified by 4D-MSPECT and ECT in the same patient group and a qualitative comparison of the reconstructed slices by two different experts. Materials and methods: Thirty-one consecutive patients underwent gated myocardial perfusion SPECT using a two-day protocol. The gated and ungated data were reconstructed by back projection method. Quantitative analysis was performed on the same set of reconstructed slices by 4D-MSPECT and Emory Cardiac Tool Box. The reconstructed slices were read qualitatively by two different experts on their respective systems. Polar map and functional analysis was performed in both softwares and the results were compared. Results: The concordance between the two experts qualitatively was seen in 78/93(84%) coronary territories. The polar map defects were comparable in LAD (r-value of 0.87) and LCX (r-value of 0.76) territories whereas RCA defects (r-value of 0.04) were not at all correlating. The defect severity showed concordance in 68/93 (73%) coronary territories. There was concordance between 4DMSPECT and the qualitative interpretation in 84/93 (90%) coronary territories whereas ECT showed concordance in only 70/93(75%) coronary territories. The overall sensitivity is marginally higher for ECT (100% vs. 96%) but the overall specificity is much higher with 4 DMSPECT (88% vs. 65%). ESV showed good correlation(r=0.94) of the two softwares with no significant difference in means. EDV and LVEF although had good correlation(r = 0.96 and 0.89) showed high difference in means (p<0.01). Conclusion: Between 4D-MSPECT and ECT, 4D-MSPECT is marginally superior to ECT with reference to qualitative interpretation in view of better specificity. The LVEF values between the two softwares should also not be used interchangeably. (author)

  15. Study of sup 123 I-IMP SPECT on diabetic patients

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Ikuo; Takeo, Goh; Iwanaga, Keisuke; Uotani, Shigeo; Nakamura, Minoru; Sohda, Masanori; Ohe, Haruto; Toshimitsu, Takashi; Ohe, Nobuharu (Yahata City Hospital, Kitakyushu, Fukuoka (Japan))

    1991-07-01

    The involvement of peripheral nerves and nerve roots often leads to neurological manifestations which have frequently been described in association with diabetes mellitus. Whether there is any specific involvement of the central nervous system in this process has yet to be determined. Recently, many reports have suggested that significant neurophysiologic abnormalities in the central nervous system can sometimes be found in diabetic patients. In order to accurately examine the existence of central nervous system involvement in patients with diabetes mellitus, comparisons of {sup 123}I-IMP (IMP) washout rates were made between normal adults (n=19, average age 43.3 years) and diabetic patients (n=23, average age 43.3 years), and these results were graphically demonstrated by color images. Early images were obtained 30 minutes after intravenous injection, while delayed images were made 4 hours after injection. The IMP washout rate was obtained by subtracting the values of the delayed image with the early image. The standard deviation (SD) of the IMP washout rate for each patient was compared to the averaged SD obtained from healthy adults. After calculating the deviation from SD levels of healthy adults, we made an image of the patient's IMP washout rates. These images were divided into seven degrees (I, II: normal, III, IV: borderline, V{approx}VII: abnormal) and the ratio of each degree was expressed by a histogram in each cerebral hemisphere as the washout rate index. In 23 diabetic subjects, seven patients were found to be borderline while sixteen patients were abnormal. These impairments were not related either to the presence of diabetic triopathy or the duration of disease. By utilising such a noninvasive method, we were able to accurately evaluate the extent of diabetic central neuropathy. Therefore this subtraction method, which uses the specificity of IMP SPECT, is thus considered to be highly useful for broad clinical application. (author).

  16. Combined study of 99mTc-HMPAO SPECT and computerized electroencephalographic topography (CET) in patients with medically refractory complex partial epilepsy

    International Nuclear Information System (INIS)

    Rodrigues, M.; Botelho, M.M.; Fonseca, A.T.; Peter, J.P.; Pimentel, T.; Vieira, M.R.

    1996-01-01

    For successful surgery for drug-resistant partial epilepsy the site of the seizure focus needs to be known exactly. The purpose of this study was to compare the evaluation of the regional cerebral blood flow (rCBF) (localization and degree of disturbances) by 99m Tc-hexamethylpropylene-amineoxime (HMPAO) single photon emission computed tomography (SPECT) with computerized electroencephalographic topography (CET) and transmission computed X-ray tomography (CT) in partial epilepsy. The study included 20 patients with medically refractory complex partial seizures. Of the 20 patients included, 15 were studied interictally, four ictally and one in both states, interictally and ictally. 99m Tc-HMPAO SPECT detected rCBF changes in 95% of the patients. Interictal studies demonstrated focal areas of hypoperfusion in 93% of the patients. Ictal studies demonstrated an area of hyperperfusion in all patients. Blood flow disturbances in deeper structures of the brain, such as basal ganglia, could be detected. The areas with abnormal 99m Tc-HMPAO uptake were concordant, in localization, with CET in 85% of the patients. Abnormal data with CT scans were found in only 45% of the patients. Focal lesions were found in 20% of the patients by CT scans. 99m Tc-HMPAO SPECT combined with CET may be a useful screening procedure prior to referral for invasive diagnostic procedures in future management of patients with medically refractory complex partial seizures. (author)

  17. The Area Method and the Table-Look-Up Method for 123I Epidepride SPECT Studies of Dopamine D2 Receptors

    DEFF Research Database (Denmark)

    Videbæk, Charlotte; Pindborg, Lars; Haldin, C

    1998-01-01

    Videbæk, C., Pinborg, L.H., Lassen, A., Halldin, C., Swahn, C-G., Yndgaard, S., Paulson, O.B. and Lassen, N.A. The Area Method and the Table-Look-Up Method for 123I Epidepride SPECT Studies of Dopamine D2 Receptors Abstract in Neuroimage 5(4), A21 Neurobiology Research Unit, Rigshospitalet, DENMA....... Dept of Nuclear Medicine, Bispebjerg Hospital, DENMARK. Dept of Anaesthesia, Rigshospitalet, DENMARK. Pept. Of Psych and Psyc. Karolinska Hospital, SVERIGE...

  18. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  19. Technical approach to improvement of SPECT images

    International Nuclear Information System (INIS)

    Fukukita, Hiroyoshi

    1985-01-01

    At present, a large number of SPECT systems are being widely used in Japan, hence, it is reasonable for us to know the physical and imaging characteristics of these SPECT devices, and also to recommend the optimum utility of SPECT systems. For this reason, a survey respect of characteristics of the commercialy available SPECT devices was carried out. In addition to this, various factors which have significant influence over SPECT image quality, such as, data acquisition matrix, reconstruction filter, γ-ray attenuation correction and daily quality control procedure, were also investigated. The materials used for this study are PET/SPECT phantom, Alderson liver phantom filled with Tc-99m solution, and either LFOV-E or ZLC-7500 interfaced to Scintipac 2400 minicomputer with 256 K byte of memory. Following are the results of this study. 1) The suitable data acquisition procedure was 128 x 128 matrix for linear sampling and approximately 64 views for angular sampling. 2) Reconstructed image using pre-processing filter with Wiener and Butterworth filters provided high quality image as compared with the Ramp filter. 3) Weighted backprojection method (WBP) proposed by Tanaka was superior to other methods, such as Sorenson method and Chang method in the object with non-uniform distribution of radionuclide. 4) It was found that uniformity correction of gamma camera and precise adjustment of the center of rotation are most important to maintain the images with a high quality. (author)

  20. 99mTc-HMPAO-SPECT in the diagnosis of senile dementia of Alzheimer's type - a study under clinical routine conditions

    International Nuclear Information System (INIS)

    Stoppe, G.; Staedt, J.; Schuetze, R.; Kunert, H.J.; Ruether, E.; Koegler, A.; Sandrock, D.; Emrich, D.

    1995-01-01

    This study was designed to evaluate whether investigations of cerebral blood flow can be a helpful diagnostic tool in the differential diagnosis between (senile) dementia of Alzheimer's type [(S)DAT] and geriatric depression with cognitive impairment. Under clinical routine conditions we performed Single Photon Emission Computed Tomography (SPECT) using 99m Tc-Hexamethylpropyleneamine Oxime (HMPAO) in 23 patients with (S)DAT (14 f, 9 m; mean age 68.9 y), 17 patients with geriatric depression (9 f, 8 m; mean age 66.4 y) and 12 age-matched controls (9 f, 3 m; mean age 69.2 y). Semiquantitative analysis (corticocerebellar ratios) of eight different regions of interest (ROI) revealed a significantly ( p 99m Tc-HMPAO SPECT is a valuable additional tool in the differential diagnosis of depression and dementia in the elderly. (author)

  1. Clinical significance of diffuse slow washout pattern (DSWO) on the exercise stress 201Tl SPECT myocardial imaging: Correlative study with influencing factors

    International Nuclear Information System (INIS)

    Wang Qian; Fumiko Nakanishi; Shusuke Sone

    1994-01-01

    DSWO shown on the Bull's eye images was found in 98 of 1234 patients suspected of having coronary artery disease and examined with 201 Tl myocardial SPECT imaging. 48 of these 98 patients underwent coronary arteriography. Comparison studies were performed between Bull's eye SPECT image, coronary arteriography and laboratory data. DSWO was found in 11 cases with single vessel disease (1VD), 18 cases with double vessel disease (2VD) and 21 cases with triple vessel disease (3VD). Three of 58 cases with stenosis of a cardiomyopathy. In the CAD group, DSWO appeared frequently accompanying hypertension, hyperlipemia and diabetes mellitus. These complications tended to increase in patients with 1VD and the stenosis less than 75%

  2. The effect of Compton scattering on quantitative SPECT imaging

    International Nuclear Information System (INIS)

    Beck, J.W.; Jaszczak, R.J.; Starmer, C.F.

    1982-01-01

    A Monte Carlo code has been developed to simulate the response of a SPECT system. The accuracy of the code has been verified and has been used in this research to study and illustrate the effects of Compton scatter on quantitative SPECT measurements. The effects of Compton scattered radiation on gamma camera response have been discussed by several authors, and will be extended to rotating gamma camera SPECT systems. The unique feature of this research includes the pictorial illustration of the Compton scattered and the unscattered components of the photopeak data on SPECT imaging by simulating phantom studies with and without Compton scatter

  3. Development of a high-resolution detection module for the INSERT SPECT/MRI system

    Energy Technology Data Exchange (ETDEWEB)

    Busca, Paolo; Fiorini, Carlo; Butt, Arslan D; Occhipinti, Michele; Quaglia, Riccardo; Trigilio, Paolo [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Via Golgi 40, 20133 Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano, Via Celoria 16, 20133 Milano (Italy); Nemeth, Gabor; Major, Peter; Bukki, Tamas; Nagy, Kalman [Mediso Medical Imaging Systems, Alsotorokvesz 14, H-1022 Budapest (Hungary); Piemonte, Claudio; Ferri, Alessandro; Gola, Alberto [Fondazione Bruno Kessler (FBK), Via Sommarive, 18, 38123 Trento (Italy); Rieger, Jan [MRI.TOOLS GmbH, Robert-Roessle-Str. 10, 13125 Berlin (Germany); Niendorf, Thoralf [MRI.TOOLS GmbH, Robert-Roessle-Str. 10, 13125 Berlin (Germany); Berlin Ultrahigh Field Facility (B.UniversityF.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin (Germany)

    2014-07-29

    A new multi-modality imaging tool is under development in the framework of the INSERT (Integrated SPECT/MRI for Enhanced Stratification in Radio-chemo Therapy) project, supported by the European Community. The final goal is to develop a custom SPECT apparatus that can be used as an insert for commercially available MRI systems. INSERT is expected to offer more effective and earlier diagnosis with potentially better outcome in survival for the treatment of brain tumors, primarily glioma. Two SPECT prototypes are being developed, one dedicated to preclinical imaging (7 and 9.4 T), the second one dedicated to clinical imaging (3 T).

  4. Development of a high-resolution detection module for the INSERT SPECT/MRI system

    International Nuclear Information System (INIS)

    Busca, Paolo; Fiorini, Carlo; Butt, Arslan D; Occhipinti, Michele; Quaglia, Riccardo; Trigilio, Paolo; Nemeth, Gabor; Major, Peter; Bukki, Tamas; Nagy, Kalman; Piemonte, Claudio; Ferri, Alessandro; Gola, Alberto; Rieger, Jan; Niendorf, Thoralf

    2014-01-01

    A new multi-modality imaging tool is under development in the framework of the INSERT (Integrated SPECT/MRI for Enhanced Stratification in Radio-chemo Therapy) project, supported by the European Community. The final goal is to develop a custom SPECT apparatus that can be used as an insert for commercially available MRI systems. INSERT is expected to offer more effective and earlier diagnosis with potentially better outcome in survival for the treatment of brain tumors, primarily glioma. Two SPECT prototypes are being developed, one dedicated to preclinical imaging (7 and 9.4 T), the second one dedicated to clinical imaging (3 T).

  5. Prognostic study of risk stratification among Japanese patients with ischemic heart disease using gated myocardial perfusion SPECT: J-ACCESS study

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Nakajima, Kenichi; Kusuoka, Hideo; Yamashina, Akira; Nishimura, Shigeyuki

    2008-01-01

    Although the prognostic value of myocardial perfusion imaging using gated single photon emission computed tomography (SPECT) for predicting major cardiac events has been evaluated, little is known about the relevance of this procedure to the Japanese population. A total of 4,031 consecutive Japanese patients with suspected or confirmed ischemic heart diseases were registered at 117 hospitals in the Japanese Assessment of Cardiac Events and Survival Study by Quantitative Gated SPECT investigation. Gated stress/rest myocardial perfusion SPECT was performed and the patients were followed up for 3 years. Segmental perfusion scores and quantitative gated SPECT results were calculated. Major cardiac events were defined as cardiac death, nonfatal myocardial infarction, and severe heart failure. During the 3-year follow-up, cardiac death (n = 57) and nonfatal myocardial infarction (n = 39) occurred in 96 patients (2.4%/3 years) when hard events were the endpoints. When severe heart failure was included as an endpoint, major cardiac events that developed in 175 patients (4.3%/3 years) comprised cardiac death (n = 45), nonfatal myocardial infarction (n = 37), and severe heart failure (n = 93). Normal and severely abnormal summed stress score values were associated with low (2.31%/3 years) and high (9.21%/3 years) rates of major cardiac events, respectively. Rates of major cardiac events were significantly higher in patients with ejection fraction (EF) <45% than in those with EF 45% or higher (16.55 vs 2.94%/3 years; P < 0.001). The incidence of major cardiac events within 3 years was also significantly higher among patients with high end-systolic volumes. The major event rates were similar among nondiabetic patients with and diabetic patients without prior myocardial infarction at 5.06% and 5.73%/3 years, respectively. Cardiac event rates were significantly lower in the Japanese than in the USA and European populations. However, large myocardial perfusion defects and

  6. Effect of linearization correction on statistical parametric mapping (SPM). A 99mTc-HMPAO brain perfusion SPECT study in mild Alzheimer's disease

    International Nuclear Information System (INIS)

    Ansar, A.B.; Osaki, Yasuhiro; Kazui, Hiroaki

    2006-01-01

    Statistical parametric mapping (SPM) was employed to investigate the regional decline in cerebral blood flow (rCBF) as measured by 99m Tc-hexamethyl propylene amine oxime (HMPAO) single photon emission computed tomography (SPECT) in mild Alzheimer's disease (AD). However, the role of the post reconstruction image processing on the interpretation of SPM, which detects rCBF pattern, has not been precisely studied. We performed 99m Tc-HMPAO SPECT in mild AD patients and analyzed the effect of linearization correction for washout of the tracer on the detectability of abnormal perfusion. Eleven mild AD (National Institute of Neurological and Communicative Disorders and National Institute of Radiological Sciences (NINCDS-ADRDA), male/female, 5/6; mean±SD age, 70.6±6.2 years; mean±SD mini-mental state examination score, 23.9±3.41; clinical dementia rating score, 1) and eleven normal control subjects (male/female, 4/7; mean±SD age, 66.8±8.4 years) were enrolled in this study. 99m Tc-HMPAO SPECT was performed with a four-head rotating gamma camera. We employed linearization uncorrected (LU) and linearization corrected (LC) images for the patients and controls. The pattern of hypoperfusion in mild AD on LU and LC images was detected by SPM99 applying the same image standardization and analytical parameters. A statistical inter image-group analysis (LU vs. LC) was also performed. Clear differences were observed between the interpretation of SPM with LU and LC images. Significant hypoperfusion in mild AD was found on the LU images in the left posterior cingulate gyrus, right precuneus, left hippocampus, left uncus, and left superior temporal gyrus (cluster level, corrected p 99m Tc-HMPAO SPECT with or without linearization correction, which should be carefully evaluated when interpreting the pattern of rCBF changes in mild Alzheimer's disease. (author)

  7. Lymphoscintigraphy and SPECT/CT in multicentric and multifocal breast cancer: does each tumour have a separate drainage pattern? Results of a Dutch multicentre study (MULTISENT)

    Energy Technology Data Exchange (ETDEWEB)

    Brouwer, O.R. [Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Netherlands Cancer Institute, Amsterdam (Netherlands); Antoni van Leeuwenhoekhospital, Amsterdam (Netherlands); Vermeeren, L.; Valdes Olmos, R.A. [Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Netherlands Cancer Institute, Amsterdam (Netherlands); Ploeg, I.M.C. van der; Rutgers, E.J.T.; Oldenburg, H.S.A. [Antoni van Leeuwenhoek Hospital, Department of Surgery, Netherlands Cancer Institute, Amsterdam (Netherlands); Loo, C.E. [Antoni van Leeuwenhoek Hospital, Department of Radiology, Netherlands Cancer Institute, Amsterdam (Netherlands); Pereira-Bouda, L.M.; Smit, F. [Rijnland Hospital, Department of Nuclear Medicine, Leiderdorp (Netherlands); Neijenhuis, P. [Rijnland Hospital, Department of Surgery, Leiderdorp (Netherlands); Vrouenraets, B.C. [Sint Lucas Andreas Hospital, Department of Surgery, Amsterdam (Netherlands); Sivro-Prndelj, F. [Sint Lucas Andreas Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Jap-a-Joe, S.M.; Borgstein, P.J. [Onze Lieve Vrouwe Gasthuis, Department of Nuclear Medicine, Amsterdam (Netherlands)

    2012-07-15

    To investigate whether lymphoscintigraphy and SPECT/CT after intralesional injection of radiopharmaceutical into each tumour separately in patients with multiple malignancies in one breast yields additional sentinel nodes compared to intralesional injection of the largest tumour only. Patients were included prospectively at four centres in The Netherlands. Lymphatic flow was studied using planar lymphoscintigraphy and SPECT/CT until 4 h after administration of {sup 99m}Tc-nanocolloid in the largest tumour. Subsequently, the smaller tumour(s) was injected intratumorally followed by the same imaging sequence. Sentinel nodes were intraoperatively localized using a gamma ray detection probe and vital blue dye. Included in the study were 50 patients. Additional lymphatic drainage was depicted after the second and/or third injection in 32 patients (64 %). Comparison of planar images and SPECT/CT images after consecutive injections enabled visualization of the number and location of additional sentinel nodes (32 axillary, 11 internal mammary chain, 2 intramammary, and 1 interpectoral. A sentinel node contained metastases in 17 patients (34 %)). In five patients with a tumour-positive node in the axilla that was visualized after the first injection, an additional involved axillary node was found after the second injection. In two patients, isolated tumour cells were found in sentinel nodes that were only visualized after the second injection, whilst the sentinel nodes identified after the first injection were tumour-negative. Lymphoscintigraphy and SPECT/CT after consecutive intratumoral injections of tracer enable lymphatic mapping of each tumour separately in patients with multiple malignancies within one breast. The high incidence of additional sentinel nodes draining from tumours other than the largest one suggests that separate tumour-related tracer injections may be a more accurate approach to mapping and sampling of sentinel nodes in patients with multicentric or

  8. Lymphoscintigraphy and SPECT/CT in multicentric and multifocal breast cancer: does each tumour have a separate drainage pattern? Results of a Dutch multicentre study (MULTISENT).

    Science.gov (United States)

    Brouwer, O R; Vermeeren, L; van der Ploeg, I M C; Valdés Olmos, R A; Loo, C E; Pereira-Bouda, L M; Smit, F; Neijenhuis, P; Vrouenraets, B C; Sivro-Prndelj, F; Jap-a-Joe, S M; Borgstein, P J; Rutgers, E J Th; Oldenburg, H S A

    2012-07-01

    To investigate whether lymphoscintigraphy and SPECT/CT after intralesional injection of radiopharmaceutical into each tumour separately in patients with multiple malignancies in one breast yields additional sentinel nodes compared to intralesional injection of the largest tumour only. Patients were included prospectively at four centres in The Netherlands. Lymphatic flow was studied using planar lymphoscintigraphy and SPECT/CT until 4 h after administration of (99m)Tc-nanocolloid in the largest tumour. Subsequently, the smaller tumour(s) was injected intratumorally followed by the same imaging sequence. Sentinel nodes were intraoperatively localized using a gamma ray detection probe and vital blue dye. Included in the study were 50 patients. Additional lymphatic drainage was depicted after the second and/or third injection in 32 patients (64%). Comparison of planar images and SPECT/CT images after consecutive injections enabled visualization of the number and location of additional sentinel nodes (32 axillary, 11 internal mammary chain, 2 intramammary, and 1 interpectoral. A sentinel node contained metastases in 17 patients (34%). In five patients with a tumour-positive node in the axilla that was visualized after the first injection, an additional involved axillary node was found after the second injection. In two patients, isolated tumour cells were found in sentinel nodes that were only visualized after the second injection, whilst the sentinel nodes identified after the first injection were tumour-negative. Lymphoscintigraphy and SPECT/CT after consecutive intratumoral injections of tracer enable lymphatic mapping of each tumour separately in patients with multiple malignancies within one breast. The high incidence of additional sentinel nodes draining from tumours other than the largest one suggests that separate tumour-related tracer injections may be a more accurate approach to mapping and sampling of sentinel nodes in patients with multicentric or

  9. Diagnostic value of asymmetric striatal D2 receptor upregulation in Parkinson's disease: an [123I]IBZM and [123I]FP-CIT SPECT study

    International Nuclear Information System (INIS)

    Verstappen, C.C.P.; Bloem, B.R.; Haaxma, C.A.; Horstink, M.W.I.M.; Oyen, W.J.G.

    2007-01-01

    Striatal postsynaptic D 2 receptors in Parkinson's disease (PD) are thought to be upregulated in the first years of the disease, especially contralateral to the clinically most affected side. The aim of this study was to evaluate whether the highest striatal D 2 binding is found contralateral to the most affected side in PD, and whether this upregulation can be used as a diagnostic tool. Cross-sectional survey was undertaken of 81 patients with clinically asymmetric PD, without antiparkinsonian drugs and with a disease duration of ≤5 years and 26 age-matched controls. Striatal D 2 binding was assessed with [ 123 I]IBZM SPECT, and severity of the presynaptic dopaminergic lesion with [ 123 I]FP-CIT SPECT. The mean striato-occipital ratio of [ 123 I]IBZM binding was significantly higher in PD patients (1.56 ±0.09) than in controls (1.53 ±0.06). In PD patients, higher values were found contralateral to the clinically most affected side (1.57 ±0.09 vs 1.55 ±0.10 ipsilaterally), suggesting D 2 receptor upregulation, and the reverse was seen using [ 123 I]FP-CIT SPECT. However, on an individual basis only 56% of PD patients showed this upregulation. Our study confirms asymmetric D 2 receptor upregulation in PD. However, the sensitivity of contralateral higher striatal [ 123 I]IBZM binding is only 56%. Therefore, the presence of contralateral higher striatal IBZM binding has insufficient diagnostic accuracy for PD, and PD cannot be excluded in patients with parkinsonism and no contralateral upregulation of D 2 receptors, assessed with [ 123 I]IBZM SPECT. (orig.)

  10. Measuring SSRI occupancy of SERT using the novel tracer [{sup 123}I]ADAM: a SPECT validation study

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, Kjell; Lui, Dominic; Townsend, Caroline E.; Ell, Peter J. [Middlesex Hospital, Institute of Nuclear Medicine, University College London, London (United Kingdom); Sivananthan, Tharani; Mu, Song; Lucas, Richard [Lilly Research Centre, Eli Lilly and Company, Windlesham, Surrey (United Kingdom); Spezzi, Andrea; Warrington, Steven [Central Middlesex Hospital, Hammersmith Medicines Research, London (United Kingdom)

    2005-11-01

    Serotonergic brain regions play a crucial role in the modulation of emotion, and serotonergic dysfunction may contribute to several neurological disorders. [{sup 123}I]ADAM is a novel SPECT tracer which binds with high affinity to serotonin transporters (SERT). The objective of this study was to compare different methods for the quantification of tracer binding and to develop a simplified single-scan protocol for this tracer, as well as to investigate its potential for characterisation of the transporter occupancy versus plasma concentration curve of a selective serotonin re-uptake inhibitor (SSRI). Dynamic SPECT scans were performed on 16 healthy volunteers after administration of {proportional_to}150 MBq [{sup 123}I]ADAM. Data were acquired from the time of injection until {proportional_to}5.5 h after injection in 30- or 45-min sessions. Each subject was scanned twice: with and without pre-treatment with the SSRI citalopram in various dosage regimens. The plasma concentration of citalopram (C{sub p}) was determined from venous samples. Images were reconstructed by filtered back-projection with scatter and attenuation correction. Tracer binding was quantified for midbrain, striatum and thalamus using cerebellum as a reference region. Quantification was done by kinetic modelling, graphical analysis and multi-linear regression, as well as by the ratio method, with binding potential (BP{sub 2}) as the outcome measure. The SERT occupancy by citalopram was determined relative to the baseline scan for each subject, and the occupancy versus C{sub p} curve was fitted with the E{sub max} model. The highest binding of [{sup 123}I]ADAM was in midbrain (mean baseline BP{sub 2}{+-}SD=1.31{+-}0.29), with lower binding in thalamus (0.79{+-}0.16) and striatum (0.66{+-}0.13). There was good agreement between BP{sub 2} values obtained by different quantification methods. Using the ratio method, the best agreement with kinetic modelling was obtained with data from the time interval

  11. Dopaminergic dysfunction and psychiatric symptoms in movement disorders: a {sup 123}I-FP-CIT SPECT study

    Energy Technology Data Exchange (ETDEWEB)

    Di Giuda, Daniela; Cocciolillo, Fabrizio; Bruno, Isabella; Giordano, Alessandro [Universita Cattolica del Sacro Cuore, Istituto di Medicina Nucleare, Rome (Italy); Camardese, Giovanni; Pucci, Lorella; Janiri, Luigi [Universita Cattolica del Sacro Cuore, Istituto di Psichiatria e Psicologia, Rome (Italy); Bentivoglio, Anna Rita; Guidubaldi, Arianna [Universita Cattolica del Sacro Cuore, Istituto di Neurologia, Rome (Italy); Fasano, Alfonso [Universita Cattolica del Sacro Cuore, Istituto di Neurologia, Rome (Italy); AFaR-Associazione Fatebenefratelli per la Ricerca, Rome (Italy)

    2012-12-15

    Psychiatric symptoms frequently occur in patients with movement disorders. They are not a mere reaction to chronic disability, but most likely due to a combination of psychosocial factors and biochemical dysfunction underlying the movement disorder. We assessed dopamine transporter (DAT) availability by means of {sup 123}I-FP-CIT SPECT, and motor and psychiatric features in patients with Parkinson's disease, primary dystonia and essential tremor, exploring the association between SPECT findings and symptom severity. Enrolled in the study were 21 patients with Parkinson's disease, 14 patients with primary dystonia and 15 patients with essential tremor. The severity of depression symptoms was assessed using the Hamilton depression rating scale, anxiety levels using the Hamilton anxiety rating scale and hedonic tone impairment using the Snaith-Hamilton pleasure scale. Specific {sup 123}I-FP-CIT binding in the caudate and putamen was calculated based on ROI analysis. The control group included 17 healthy subjects. As expected, DAT availability was significantly decreased in patients with Parkinson's disease, whereas in essential tremor and dystonia patients it did not differ from that observed in the control group. In Parkinson's disease patients, an inverse correlation between severity of depression symptoms and DAT availability in the left caudate was found (r = -0.63, p = 0.002). In essential tremor patients, levels of anxiety symptoms were inversely correlated with DAT availability in the left caudate (r = -0.69, p = 0.004). In dystonia patients, the severities of both anxiety and depression symptoms were inversely associated with DAT availability in the left putamen (r = -0.71, p = 0.004, and r = -0.75, p = 0.002, respectively). There were no correlations between psychometric scores and {sup 123}I-FP-CIT uptake ratios in healthy subjects. We found association between presynaptic dopaminergic function and affective symptoms in different movement

  12. Measuring SSRI occupancy of SERT using the novel tracer [123I]ADAM: a SPECT validation study

    International Nuclear Information System (INIS)

    Erlandsson, Kjell; Lui, Dominic; Townsend, Caroline E.; Ell, Peter J.; Sivananthan, Tharani; Mu, Song; Lucas, Richard; Spezzi, Andrea; Warrington, Steven

    2005-01-01

    Serotonergic brain regions play a crucial role in the modulation of emotion, and serotonergic dysfunction may contribute to several neurological disorders. [ 123 I]ADAM is a novel SPECT tracer which binds with high affinity to serotonin transporters (SERT). The objective of this study was to compare different methods for the quantification of tracer binding and to develop a simplified single-scan protocol for this tracer, as well as to investigate its potential for characterisation of the transporter occupancy versus plasma concentration curve of a selective serotonin re-uptake inhibitor (SSRI). Dynamic SPECT scans were performed on 16 healthy volunteers after administration of ∝150 MBq [ 123 I]ADAM. Data were acquired from the time of injection until ∝5.5 h after injection in 30- or 45-min sessions. Each subject was scanned twice: with and without pre-treatment with the SSRI citalopram in various dosage regimens. The plasma concentration of citalopram (C p ) was determined from venous samples. Images were reconstructed by filtered back-projection with scatter and attenuation correction. Tracer binding was quantified for midbrain, striatum and thalamus using cerebellum as a reference region. Quantification was done by kinetic modelling, graphical analysis and multi-linear regression, as well as by the ratio method, with binding potential (BP 2 ) as the outcome measure. The SERT occupancy by citalopram was determined relative to the baseline scan for each subject, and the occupancy versus C p curve was fitted with the E max model. The highest binding of [ 123 I]ADAM was in midbrain (mean baseline BP 2 ±SD=1.31±0.29), with lower binding in thalamus (0.79±0.16) and striatum (0.66±0.13). There was good agreement between BP 2 values obtained by different quantification methods. Using the ratio method, the best agreement with kinetic modelling was obtained with data from the time interval [200,260] min after injection. The fitting of the midbrain occupancy curve

  13. Cerebral control of bladder storage in patients with detrusor overactivity: An activation study using SPECT with NEUROSTAT

    International Nuclear Information System (INIS)

    Yafu, Y.; Li, X.; Li, Y.

    2007-01-01

    Full text: The aim of this study was to identify the brain areas which control the bladder storage in the patients with detrusor overactivity (DO) and those without DO by 99mTc-hexamethylpropylene amine oxime (99mTc-HMPAO) SPECT with Neurological Statistical Image Analysis Software (NEUROSTAT). Methods: SPECT scans were performed on fifteen healthy volunteers (Group I) and twenty-five patients with some storage symptoms of lower urinary tract, among whom nineteen patients were with DO (Group II) and six patients were with normal detrusor function (Group III). All the subjects were male and right-handed. Each subject was scanned twice without movement in a supine position. 444MBq and 555MBq 99mTc- HMPAO were separately injected intravenously under the following two conditions: resting state with empty bladder and urine withholding state with full bladder. The final image during urine withholding was obtained by subtracting the first scan data from the second. NEUROSTAT was adopted to analyze the difference in rCBF between groups in resting state and to analyze the change in rCBF between urine withholding and resting states in each group. The results were displayed on Z-score images at a significance threshold of P < 0.05 with correction for multiple comparisons. Results: No region reached significant threshold in comparison of Group II and Group III in resting state, although Group II and III , as compared with Group I, showed decreases in tracer activity in superior temporal gyrus, medial frontal gyrus, inferior frontal gyrus, anterior cingulate and cingulate gyrus. There were significant increases in tracer activity in bilateral inferior frontal gyri and the right middle temporal gyrus in urine withholding state as compared with resting state in Group III. Among the regions, the right inferior frontal gyrus was distinctly prominent at both Z-score and the extent. In Group II, the regions that were activated significantly in Group III did not reach significant

  14. Incremental value of 99mTc-HYNIC-TOC SPECT/CT over whole-body planar scintigraphy and SPECT in patients with neuroendocrine tumours.

    Science.gov (United States)

    Trogrlic, Mate; Težak, Stanko

    2017-06-12

    The aim of this study was to evaluate the additional value of 99m Tc-HYNIC-TOC SPECT/CT over planar whole-body (WB) scintigraphy and SPECT alone in the detection and accurate localisation of neuroendocrine tumour (NET) lesions. This study included 65 patients with a definitive histological diagnosis of NET prior to scintigraphy. Planar WB scintigraphy, SPECT, and SPECT/CT images were acquired at 4 h post-administration of 670 MBq 99m Tc-HYNIC-TOC. Additional SPECT images at 10 min after tracer administration were also acquired. Clinical and imaging follow-up findings were considered as the reference standards (minimum follow-up period, 15 months). Patient and lesion-based analyses of the efficacies of the imaging modalities were performed. While 38 patients exhibited metastasis of NETs, 27 presented no evidence of metastasis. Upon patient-based analysis, the sensitivity and specificity of SPECT/CT were found to be 88.9 and 79.3 %, respectively. The diagnostic accuracies of WB scintigraphy, 4h-SPECT, and SPECT/CT were 72.3, 73.8, and 84.6 %, respectively. The area under curve (AUC) value for SPECT/CT (0.84) was the highest, followed by those for 4h-SPECT (0.75) and WB scintigraphy (0.74). The accuracy and AUC values of SPECT/CT were significantly better compared to those of WB scintigraphy (p < 0.001), 10 min-SPECT (p < 0.001), and 4 h-SPECT (p = 0.001). The findings of SPECT/CT led to the change in treatment plan of 11 patients (16.9 %). The sensitivity and diagnostic accuracy of SPECT/CT in the evaluation of NET lesions outperforms planar WB imaging or SPECT alone.

  15. SPECT in psychiatry

    International Nuclear Information System (INIS)

    Barocka, A.; Feistel, H.; Ebert, D.; Lungershausen, E.

    1993-01-01

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D 2 and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.) [de

  16. I-123 Iofetamine SPECT scan in children with neurological disorders

    International Nuclear Information System (INIS)

    Flamini, J.R.; Konkol, R.J.; Wells, R.G.; Sty, J.R.

    1990-01-01

    I-123 Iofetamine (IMP) single photon emission computed tomography (SPECT) imaging of the brain in 42 patients (ages 14 days to 23 years) was compared with other localizing studies in children with neurological diseases. All had an EEG and at least one imaging study of the brain (computed tomography (CT) or magnetic resonance imaging (MRI), or both). Seventy-eight percent of the patients had an EEG within 24-72 hours of the IMP-SPECT scan. Thirty-five (83%) had a history of seizures, and the remainder had other neurological conditions without a history of seizures. In most cases, a normal EEG reading with normal CT or MRI result predicted a normal SPECT study. When the EEG was abnormal the majority of the IMP-SPECT scans were abnormal and localized the abnormality to the same region. A comparison with CT and MRI showed that structural abnormalities involving the cortex were usually well demonstrated with IMP-SPECT imaging. Structural lesions confined to the white matter were generally not detectable with IMP-SPECT. In a few cases, SPECT scans revealed abnormalities in deep brain areas not identified by EEG. IMP-SPECT imaging is a valuable technique for the detection and localization of abnormal cerebral metabolic activity in children with seizure disorders. A correlation with CT or MRI is essential for proper interpretation of abnormalities detected with IMP SPECT imaging

  17. Preclinical and phase I studies of monoclonal antibodies in melanoma: Application to boron neutron capture therapy of melanoma

    International Nuclear Information System (INIS)

    Hersey, P.

    1989-01-01

    Monoclonal antibodies (MAbs) provide an attractive method of selectively localizing sufficient boron atoms around tumour cells to capture neutrons. Assuming that 10(8)-10(10) 10B atoms are needed for one capture event and that 10(3)-10(4) atoms can be coupled to each antibody molecule, then 10(5)-10(6) antibody molecules gathered on an individual cell will destroy that cell. Binding to normal tissues, on the other hand, would need to be at least 20-fold less than that to tumour tissues to avoid toxic effects of neutrons on surrounding tissues. Preclinical studies in animals show that several MAbs may bind to melanoma cells in sufficient quantities in vitro to localize the required amount of boron per cell. Whether this will occur in vivo, however, may depend not only on antigen density but a variety of other properties of the tumour cells and MAbs. These include the Ig class and affinity of the antibody and whether the antibody is internalized into the tumour cell. The ratio of uptake between tumour and normal tissue is governed by such factors as the percentage of tumour cells within a tumour expressing the antigen and whether the MAb react with normal tissues. Use of Fab or F(ab)2 preparations of the MAb may increase the uptake ratio by preventing uptake of MAb by cells with Fc receptors. In contrast to preclinical animal studies, tumour/normal tissue uptake ratios in phase I studies in humans have been disappointingly low.80 references

  18. {alpha}4 {beta}2 nicotinic acetylcholine receptor in Alzheimer's disease and mild cognitive impairment: a study with 5-[I-123]iodo-A-85380 SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Eun Kyung; Kim, Yu Kyeong; Kim, Sang Yun; Kim, Sang Eun [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    2007-07-01

    It has been reported that the number of neuronal nicotinic acetylcholine receptors (nAChRs) is decreased in Alzheimer's disease (AD) and the degree of cholinergic deficit is correlated with cognitive impairment. We examined neuronal nAChR distribution of AD patients using 5-[I-123]iodo-A85380 (5-IA) SPECT and correlated it with the pattern of cerebral glucose metabolic impairment and the severity of cognitive impairment. Five clinically diagnosed AD patients, 5 amnestic mild cognitive impairment (MCI) patients, and 10 age- and sex-matched healthy controls were studied with 5-IA SPECT and brain FDG PET. 5-IA SPECT was performed for 30 min at 120 min after radiotracer injection. FDG PET was done within one month interval. Neuropsychological tests were done for cognitive evaluation. A nAChR parameter DV was calculated in brain regions using cerebellum as reference tissue. All scan images were analyzed using SPM2 and ANOVA was done for group comparison. P value less than 0.005 was considered significant. 5-IA SPECT images of AD patients revealed significantly reduced nAChR distribution in the anterior cingulate cortex, striatum, and the left temporal cortex. MCI patients demonstrated decreased receptor distribution mainly in the subcortical areas. Cortical nAChR distribution showed correlation with cortical glucose metabolism and subcortical with that of posterior cingulate cortex (PCC). Episodic memory and semantic verbal fluency showed significant correlation with nAChR distribution of periventricular white matter (PVWM), visuospatial function evaluated with RCFT with that of PCC, left temporoparietal cortex, and frontal lobe white matter, and MMSE with that of PVWM, frontal cortex, and striatum. These data demonstrate reduction of nAChR distribution in patients with AD, which has significant correlation with cerebral glucose metabolism and cognitive impairment. It might be useful for diagnosis of AD, and for monitoring individualized treatments targeted at nAChRs.

  19. α4 β2 nicotinic acetylcholine receptor in Alzheimer's disease and mild cognitive impairment: a study with 5-[I-123]iodo-A-85380 SPECT

    International Nuclear Information System (INIS)

    Park, Eun Kyung; Kim, Yu Kyeong; Kim, Sang Yun; Kim, Sang Eun

    2007-01-01

    It has been reported that the number of neuronal nicotinic acetylcholine receptors (nAChRs) is decreased in Alzheimer's disease (AD) and the degree of cholinergic deficit is correlated with cognitive impairment. We examined neuronal nAChR distribution of AD patients using 5-[I-123]iodo-A85380 (5-IA) SPECT and correlated it with the pattern of cerebral glucose metabolic impairment and the severity of cognitive impairment. Five clinically diagnosed AD patients, 5 amnestic mild cognitive impairment (MCI) patients, and 10 age- and sex-matched healthy controls were studied with 5-IA SPECT and brain FDG PET. 5-IA SPECT was performed for 30 min at 120 min after radiotracer injection. FDG PET was done within one month interval. Neuropsychological tests were done for cognitive evaluation. A nAChR parameter DV was calculated in brain regions using cerebellum as reference tissue. All scan images were analyzed using SPM2 and ANOVA was done for group comparison. P value less than 0.005 was considered significant. 5-IA SPECT images of AD patients revealed significantly reduced nAChR distribution in the anterior cingulate cortex, striatum, and the left temporal cortex. MCI patients demonstrated decreased receptor distribution mainly in the subcortical areas. Cortical nAChR distribution showed correlation with cortical glucose metabolism and subcortical with that of posterior cingulate cortex (PCC). Episodic memory and semantic verbal fluency showed significant correlation with nAChR distribution of periventricular white matter (PVWM), visuospatial function evaluated with RCFT with that of PCC, left temporoparietal cortex, and frontal lobe white matter, and MMSE with that of PVWM, frontal cortex, and striatum. These data demonstrate reduction of nAChR distribution in patients with AD, which has significant correlation with cerebral glucose metabolism and cognitive impairment. It might be useful for diagnosis of AD, and for monitoring individualized treatments targeted at nAChRs

  20. Y-90 SPECT ML image reconstruction with a new model for tissue-dependent bremsstrahlung production using CT information: a proof-of-concept study

    Science.gov (United States)

    Lim, Hongki; Fessler, Jeffrey A.; Wilderman, Scott J.; Brooks, Allen F.; Dewaraja, Yuni K.

    2018-06-01

    While the yield of positrons used in Y-90 PET is independent of tissue media, Y-90 SPECT imaging is complicated by the tissue dependence of bremsstrahlung photon generation. The probability of bremsstrahlung production is proportional to the square of the atomic number of the medium. Hence, the same amount of activity in different tissue regions of the body will produce different numbers of bremsstrahlung photons. Existing reconstruction methods disregard this tissue-dependency, potentially impacting both qualitative and quantitative imaging of heterogeneous regions of the body such as bone with marrow cavities. In this proof-of-concept study, we propose a new maximum-likelihood method that incorporates bremsstrahlung generation probabilities into the system matrix, enabling images of the desired Y-90 distribution to be reconstructed instead of the ‘bremsstrahlung distribution’ that is obtained with existing methods. The tissue-dependent probabilities are generated by Monte Carlo simulation while bone volume fractions for each SPECT voxel are obtained from co-registered CT. First, we demonstrate the tissue dependency in a SPECT/CT imaging experiment with Y-90 in bone equivalent solution and water. Visually, the proposed reconstruction approach better matched the true image and the Y-90 PET image than the standard bremsstrahlung reconstruction approach. An XCAT phantom simulation including bone and marrow regions also demonstrated better agreement with the true image using the proposed reconstruction method. Quantitatively, compared with the standard reconstruction, the new method improved estimation of the liquid bone:water activity concentration ratio by 40% in the SPECT measurement and the cortical bone:marrow activity concentration ratio by 58% in the XCAT simulation.

  1. A pilot study of SPECT/CT-based mixed-reality navigation towards the sentinel node in patients with melanoma or Merkel cell carcinoma of a lower extremity.

    Science.gov (United States)

    van den Berg, Nynke S; Engelen, Thijs; Brouwer, Oscar R; Mathéron, Hanna M; Valdés-Olmos, Renato A; Nieweg, Omgo E; van Leeuwen, Fijs W B

    2016-08-01

    To explore the feasibility of an intraoperative navigation technology based on preoperatively acquired single photon emission computed tomography combined with computed tomography (SPECT/CT) images during sentinel node (SN) biopsy in patients with melanoma or Merkel cell carcinoma. Patients with a melanoma (n=4) or Merkel cell carcinoma (n=1) of a lower extremity scheduled for wide re-excision of the primary lesion site and SN biopsy were studied. Following a Tc-nanocolloid injection and lymphoscintigraphy, SPECT/CT images were acquired with a reference target (ReTp) fixed on the leg or the iliac spine. Intraoperatively, a sterile ReTp was placed at the same site to enable SPECT/CT-based mixed-reality navigation of a gamma ray detection probe also containing a reference target (ReTgp).The accuracy of the navigation procedure was determined in the coronal plane (x, y-axis) by measuring the discrepancy between standard gamma probe-based SN localization and mixed-reality-based navigation to the SN. To determine the depth accuracy (z-axis), the depth estimation provided by the navigation system was compared to the skin surface-to-node distance measured in the computed tomography component of the SPECT/CT images. In four of five patients, it was possible to navigate towards the preoperatively defined SN. The average navigational error was 8.0 mm in the sagittal direction and 8.5 mm in the coronal direction. Intraoperative sterile ReTp positioning and tissue movement during surgery exerted a distinct influence on the accuracy of navigation. Intraoperative navigation during melanoma or Merkel cell carcinoma surgery is feasible and can provide the surgeon with an interactive 3D roadmap towards the SN or SNs in the groin. However, further technical optimization of the modality is required before this technology can become routine practice.

  2. A method for comparing intra-tumoural radioactivity uptake heterogeneity in preclinical positron emission tomography studies

    International Nuclear Information System (INIS)

    Grafström, Jonas; Ahlzén, Hanna-Stina; Stone-Elander, Sharon

    2015-01-01

    Non-uniformity influences the interpretation of nuclear medicine based images and consequently their use in treatment planning and monitoring. However, no standardised method for evaluating and ranking heterogeneity exists. Here, we have developed a general algorithm that provides a ranking and a visualisation of the heterogeneity in small animal positron emission tomography (PET) images. The code of the algorithm was written using the Matrix Laboratory software (MATLAB). Parameters known to influence the heterogeneity (distances between deviating peaks, gradients and size compensations) were incorporated into the algorithm. All data matrices were mathematically constructed in the same format with the aim of maintaining overview and control. Histograms visualising the spread and frequency of contributions to the heterogeneity were also generated. The construction of the algorithm was tested using mathematically generated matrices and by varying post-processing parameters. It was subsequently applied in comparisons of radiotracer uptake in preclinical images in human head and neck carcinoma and endothelial and ovarian carcinoma xenografts. Using the developed algorithm, entire tissue volumes could be assessed and gradients could be handled in an indirect manner. Similar-sized volumes could be compared without modifying the algorithm. Analyses of the distribution of different tracers gave results that were generally in accordance with single plane preclinical images, indicating that it could appropriately handle comparisons of targeting vs. non-targeting tracers and also for different target levels. Altering the reconstruction algorithm, pixel size, tumour ROI volumes and lower cut-off limits affected the calculated heterogeneity factors in expected directions but did not reverse conclusions about which tumour was more or less heterogeneous. The algorithm constructed is an objective and potentially user-friendly tool for one-to-one comparisons of heterogeneity in

  3. A method for comparing intra-tumoural radioactivity uptake heterogeneity in preclinical positron emission tomography studies

    Energy Technology Data Exchange (ETDEWEB)

    Grafström, Jonas; Ahlzén, Hanna-Stina [Division of Biochemistry, Department of Medical Biochemistry and Biophysics, Karolinska Institutet, SE-17177 Stockholm (Sweden); Stone-Elander, Sharon [Department of Clinical Neuroscience, Karolinska Institutet, SE-17176 Stockholm (Sweden); PET Radiochemistry, Neuroradiology Department, Karolinska University Hospital, SE-17176 Stockholm (Sweden)

    2015-09-08

    Non-uniformity influences the interpretation of nuclear medicine based images and consequently their use in treatment planning and monitoring. However, no standardised method for evaluating and ranking heterogeneity exists. Here, we have developed a general algorithm that provides a ranking and a visualisation of the heterogeneity in small animal positron emission tomography (PET) images. The code of the algorithm was written using the Matrix Laboratory software (MATLAB). Parameters known to influence the heterogeneity (distances between deviating peaks, gradients and size compensations) were incorporated into the algorithm. All data matrices were mathematically constructed in the same format with the aim of maintaining overview and control. Histograms visualising the spread and frequency of contributions to the heterogeneity were also generated. The construction of the algorithm was tested using mathematically generated matrices and by varying post-processing parameters. It was subsequently applied in comparisons of radiotracer uptake in preclinical images in human head and neck carcinoma and endothelial and ovarian carcinoma xenografts. Using the developed algorithm, entire tissue volumes could be assessed and gradients could be handled in an indirect manner. Similar-sized volumes could be compared without modifying the algorithm. Analyses of the distribution of different tracers gave results that were generally in accordance with single plane preclinical images, indicating that it could appropriately handle comparisons of targeting vs. non-targeting tracers and also for different target levels. Altering the reconstruction algorithm, pixel size, tumour ROI volumes and lower cut-off limits affected the calculated heterogeneity factors in expected directions but did not reverse conclusions about which tumour was more or less heterogeneous. The algorithm constructed is an objective and potentially user-friendly tool for one-to-one comparisons of heterogeneity in

  4. High-throughput high-volume nuclear imaging for preclinical in vivo compound screening§.

    Science.gov (United States)

    Macholl, Sven; Finucane, Ciara M; Hesterman, Jacob; Mather, Stephen J; Pauplis, Rachel; Scully, Deirdre; Sosabowski, Jane K; Jouannot, Erwan

    2017-12-01

    Preclinical single-photon emission computed tomography (SPECT)/CT imaging studies are hampered by low throughput, hence are found typically within small volume feasibility studies. Here, imaging and image analysis procedures are presented that allow profiling of a large volume of radiolabelled compounds within a reasonably short total study time. Particular emphasis was put on quality control (QC) and on fast and unbiased image analysis. 2-3 His-tagged proteins were simultaneously radiolabelled by 99m Tc-tricarbonyl methodology and injected intravenously (20 nmol/kg; 100 MBq; n = 3) into patient-derived xenograft (PDX) mouse models. Whole-body SPECT/CT images of 3 mice simultaneously were acquired 1, 4, and 24 h post-injection, extended to 48 h and/or by 0-2 h dynamic SPECT for pre-selected compounds. Organ uptake was quantified by automated multi-atlas and manual segmentations. Data were plotted automatically, quality controlled and stored on a collaborative image management platform. Ex vivo uptake data were collected semi-automatically and analysis performed as for imaging data. >500 single animal SPECT images were acquired for 25 proteins over 5 weeks, eventually generating >3500 ROI and >1000 items of tissue data. SPECT/CT images clearly visualized uptake in tumour and other tissues even at 48 h post-injection. Intersubject uptake variability was typically 13% (coefficient of variation, COV). Imaging results correlated well with ex vivo data. The large data set of tumour, background and systemic uptake/clearance data from 75 mice for 25 compounds allows identification of compounds of interest. The number of animals required was reduced considerably by longitudinal imaging compared to dissection experiments. All experimental work and analyses were accomplished within 3 months expected to be compatible with drug development programmes. QC along all workflow steps, blinding of the imaging contract research organization to compound properties and

  5. Influence of void on image quality of industrial SPECT

    International Nuclear Information System (INIS)

    Park, J G; Jung, S H; Kim, J B; Moon, J; Kim, C H

    2013-01-01

    Industrial single photon emission computed tomography (SPECT) is a promising technique to determine the dynamic behavior of industrial process media and has been developed in the Korea Atomic Energy Research Institute. The present study evaluated the influence of a void, which is presence in multiphase reactors of industrial process, on the image quality of an industrial SPECT. The results are very encouraging; that is, the performance of the industrial SPECT system is little influenced by the presence of a void, which means that industrial SPECT is an appropriate tool to estimate the dynamic characteristics of the process media in a water-air phase bubble column with a static gas sparger

  6. Upregulated GABA inhibitory function in AD/HD children with Child Behavior Checklist–Dysregulation Profile: 123I-iomazenil SPECT study

    Directory of Open Access Journals (Sweden)

    Shinichiro eNagamitsu

    2015-06-01

    Full Text Available The Child Behavior Checklist–Dysregulation Profile (CBCL-DP refers to a pattern of elevated scores on the Attention Problems, Aggression, and Anxiety/Depression subscales of the Child Behavior Checklist. The aim of the present study was to investigate the potential role of GABA inhibitory neurons in children with attention deficit/hyperactivity disorder (AD/HD and dysregulation assessed with a dimensional measure. Brain single photon emission computed tomography (SPECT was performed in 35 children with AD/HD using 123I-iomazenil, which binds with high affinity to benzodiazepine receptors. Iomazenil binding activities were assessed with respect to the presence or absence of a threshold CBCL-DP (a score ≥210 for the sum of the three subscales Attention Problems, Aggression, and Anxiety/Depression. We then attempted to identify which CBCL-DP subscale explained the most variance with respect to SPECT data, using age, sex, and history of maltreatment as covariates. Significantly higher iomazenil binding activity was seen in the posterior cingulate cortex (PCC of AD/HD children with a significant CBCL-DP. The Anxiety/Depression subscale on the CBCL had significant effects on higher iomazenil binding activity in the left superior frontal, middle frontal, and temporal regions, as well as in the PCC. The present brain SPECT findings suggest that GABAergic inhibitory neurons may play an important role in the neurobiology of the CBCL-DP, in children with ADHD.

  7. Predictive value of dorso-lateral prefrontal connectivity for rTMS response in treatment-resistant depression: A brain perfusion SPECT study.

    Science.gov (United States)

    Richieri, Raphaëlle; Verger, Antoine; Boyer, Laurent; Boucekine, Mohamed; David, Anthony; Lançon, Christophe; Cermolacce, Michel; Guedj, Eric

    2018-05-18

    Previous clinical trials have suggested that repetitive transcranial magnetic stimulation (rTMS) has a significant antidepressant effect in patients with treatment resistant depression (TRD). However, results remain heterogeneous with many patients without effective response. The aim of this SPECT study was to determine before treatment the predictive value of the connectivity of the stimulated area on further rTMS response in patients with TRD. Fifty-eight TRD patients performed a brain perfusion SPECT before high frequency rTMS of the left dorsolateral prefrontal cortex (DLPFC). A voxel based-analysis was achieved to compare connectivity of the left DLPFC in responders and non-responders using inter-regional correlations (p left DLPFC and the right cerebellum in comparison to non-responders, independently of age, gender, severity of depression, and severity of treatment resistance. The area under the curve for the combination of these two SPECT clusters to predict rTMS response was 0.756 (p left DLPFC predicts rTMS response before treatment. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  8. Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

    Energy Technology Data Exchange (ETDEWEB)

    Razali, Azhani Mohd, E-mail: azhani@nuclearmalaysia.gov.my; Abdullah, Jaafar, E-mail: jaafar@nuclearmalaysia.gov.my [Plant Assessment Technology (PAT) Group, Industrial Technology Division, Malaysian Nuclear Agency, Bangi, 43000 Kajang (Malaysia)

    2015-04-29

    Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

  9. Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

    International Nuclear Information System (INIS)

    Razali, Azhani Mohd; Abdullah, Jaafar

    2015-01-01

    Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm

  10. Image reconstruction of single photon emission computed tomography (SPECT) on a pebble bed reactor (PBR) using expectation maximization and exact inversion algorithms: Comparison study by means of numerical phantom

    Science.gov (United States)

    Razali, Azhani Mohd; Abdullah, Jaafar

    2015-04-01

    Single Photon Emission Computed Tomography (SPECT) is a well-known imaging technique used in medical application, and it is part of medical imaging modalities that made the diagnosis and treatment of disease possible. However, SPECT technique is not only limited to the medical sector. Many works are carried out to adapt the same concept by using high-energy photon emission to diagnose process malfunctions in critical industrial systems such as in chemical reaction engineering research laboratories, as well as in oil and gas, petrochemical and petrochemical refining industries. Motivated by vast applications of SPECT technique, this work attempts to study the application of SPECT on a Pebble Bed Reactor (PBR) using numerical phantom of pebbles inside the PBR core. From the cross-sectional images obtained from SPECT, the behavior of pebbles inside the core can be analyzed for further improvement of the PBR design. As the quality of the reconstructed image is largely dependent on the algorithm used, this work aims to compare two image reconstruction algorithms for SPECT, namely the Expectation Maximization Algorithm and the Exact Inversion Formula. The results obtained from the Exact Inversion Formula showed better image contrast and sharpness, and shorter computational time compared to the Expectation Maximization Algorithm.

  11. Focused ultrasound-induced blood-brain barrier opening to enhance temozolomide delivery for glioblastoma treatment: a preclinical study.

    Directory of Open Access Journals (Sweden)

    Kuo-Chen Wei

    Full Text Available The purpose of this study is to assess the preclinical therapeutic efficacy of magnetic resonance imaging (MRI-monitored focused ultrasound (FUS-induced blood-brain barrier (BBB disruption to enhance Temozolomide (TMZ delivery for improving Glioblastoma Multiforme (GBM treatment. MRI-monitored FUS with microbubbles was used to transcranially disrupt the BBB in brains of Fisher rats implanted with 9L glioma cells. FUS-BBB opening was spectrophotometrically determined by leakage of dyes into the brain, and TMZ was quantitated in cerebrospinal fluid (CSF and plasma by LC-MS\\MS. The effects of treatment on tumor progression (by MRI, animal survival and brain tissue histology were investigated. Results demonstrated that FUS-BBB opening increased the local accumulation of dyes in brain parenchyma by 3.8-/2.1-fold in normal/tumor tissues. Compared to TMZ alone, combined FUS treatment increased the TMZ CSF/plasma ratio from 22.7% to 38.6%, reduced the 7-day tumor progression ratio from 24.03 to 5.06, and extended the median survival from 20 to 23 days. In conclusion, this study provided preclinical evidence that FUS BBB-opening increased the local concentration of TMZ to improve the control of tumor progression and animal survival, suggesting its clinical potential for improving current brain tumor treatment.

  12. Impact of a Differential Learning Approach on Practical Exam Performance: A Controlled Study in a Preclinical Dental Course.

    Science.gov (United States)

    Pabel, Sven-Olav; Pabel, Anne-Kathrin; Schmickler, Jan; Schulz, Xenia; Wiegand, Annette

    2017-09-01

    The aim of this study was to evaluate if differential learning in a preclinical dental course impacted the performance of dental students in a practical exam (preparation of a gold partial crown) immediately after the training session and 20 weeks later compared to conventional learning. This controlled study was performed in a preclinical course in operative dentistry at a dental school in Germany. Third-year students were trained in preparing gold partial crowns by using either the conventional learning (n=41) or the differential learning approach (n=32). The differential learning approach consisted of 20 movement exercises with a continuous change of movement execution during the learning session, while the conventional learning approach was mainly based on repetition, a methodological series of exercises, and correction of preparations during the training phase. Practical exams were performed immediately after the training session (T1) and 20 weeks later (T2, retention test). Preparations were rated by four independent and blinded examiners. At T1, no significant difference between the performance (exam passed) of the two groups was detected (conventional learning: 54.3%, differential learning: 68.0%). At T2, significantly more students passed the exam when trained by the differential learning approach (68.8%) than by the conventional learning approach (18.9%). Interrater reliability was moderate (Kappa: 0.57, T1) or substantial (Kappa: 0.67, T2), respectively. These results suggest that a differential learning approach can increase the manual skills of dental students.

  13. Contribution of micro-scanner in the preclinical study of hepatic and pancreatic cancer treatments in rat

    International Nuclear Information System (INIS)

    Youssef Azer Akladios, Cherif

    2010-01-01

    Animal experimentation is an unavoidable step in preclinical studies and relies on small animals. In vivo imaging constitutes a precious tool giving information on anatomy, biochemistry, physiology, genetic, pharmacology, while saving cell and tissue integrities of investigated animals. It opens wide the scientific perspective in the field of biological development, physiopathology of diseases, as well as in oncology, from early diagnosis to cancer treatment. This thesis had demonstrated the relevance of micro-scanner in the longitudinal follow up and the management of ortho-topic models of hepatic and pancreatic carcinoma in the rat. For both of these cancers, known to be very poorly or even non curable, there is an urgent need of research on the bases of their onco-genesis as of investigation of the resulting new therapeutic routes. The results of our thesis suggest a role for micro-CT in the preclinical evaluation of their emerging therapies. As far as animal experiment is concerned, in vivo micro-scanner imaging permits, beside a reduction in the number of experimental animals, to establish new (imaging) end-points allowing experiment ending before any sign of animal suffering. It fulfils the main requirements of animal experiment. (author) [fr

  14. Inter-observer variation of diagnosis of Alzheimer's disease by SPECT

    International Nuclear Information System (INIS)

    Oshima, Motoo; Machida, Kikuo; Koizumi, Kiyoshi

    2001-01-01

    SPECT shows characteristic distribution in Alzheimer's disease. The purpose of this study is to define inter-observer variations in the diagnosis of Alzheimer's disease. Fifty-seven patients, included 19 Alzheimer's disease were collected from four institutions. Five-graded score was used to interprete SPECT in 18 regions. Ten nuclear medicine physicians interpreted SPECT referred with MMSE and clinical information. Among 57 cases 19 Alzheimer's disease were selected in this study. Statistics were performed between SPECT score and MMSE score. In conclusion, inter-observer variation is present in SPECT interpretation. There was a good correlation SPECT and MMSE with proper brain SPECT physicians. They are superior to in the interpretation not only resident, but other specialists. Education in the interpretation of brain SPECT looks important. (author)

  15. Frequencies and implications of discordant findings of interictal SPECT and itcal SPECT in patients with intractable epilepsy

    International Nuclear Information System (INIS)

    Lee, D. S.; Lee, S. K.; Jeong, J. K.; Lee, M. C.; Ko, C. S.

    1997-01-01

    Interictal SPECT could be used at best as a reference image to ictal SPECT, and cause sometimes confusion if it had given unexplained discordant findings from ictal SPECT. We investigated implications of discordant findings which occurred in 26 among 268 which found their epileptogenic zones using ictal EEG and/or operative outcome. Sensitivity of interictal SPECT was only 36%. Among these 268, 69 patients had no structural lesions on MR, 14 of whom had decreased perfusion on interictal SPECT (8 trues and 6 falses (adjacent or contralateral)). Structural lesion were found in 199 on MR, 103 of whom had decreased perfusion (89 trues and 14 falses). Among 26 having discordant cases, 10 interictal SPECT were proved wrong after operation and/or invasive EEG and the other 16 were on speculation using PET and ictal EEG. Ictal hyperperfusion was observed in 14 patients in these interictal SPECT. Six ictal studies were found postictal accompanied by contralateral propagation or not. Two patients had dual pathology, and the remaining 2 unknown. Interictal SPECT was done on the 2nd day after ictal study(24), the 3rd day (18), the 4th day(16), the 5th day (23). Four among 24 interictal studies (17%) of the 2nd day and the other 4 among 57 of 3rd to 5th day revealed ictal hyperperfusion on interictal SPECT. Six interictal studies (2.7% among 221) acquired on the indifferent day showed also ictal hyperperfusion. We could suggest that the next day is not desirable for interictal SPECT after ictal study, as ictal hyperperfusion on interictal study confounded more than postictal findings of ictal SPECT in the discrete localization than reassuring ictal study

  16. Frequencies and implications of discordant findings of interictal SPECT and itcal SPECT in patients with intractable epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D S; Lee, S K; Jeong, J K; Lee, M C; Ko, C S [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    1997-07-01

    Interictal SPECT could be used at best as a reference image to ictal SPECT, and cause sometimes confusion if it had given unexplained discordant findings from ictal SPECT. We investigated implications of discordant findings which occurred in 26 among 268 which found their epileptogenic zones using ictal EEG and/or operative outcome. Sensitivity of interictal SPECT was only 36%. Among these 268, 69 patients had no structural lesions on MR, 14 of whom had decreased perfusion on interictal SPECT (8 trues and 6 falses (adjacent or contralateral)). Structural lesion were found in 199 on MR, 103 of whom had decreased perfusion (89 trues and 14 falses). Among 26 having discordant cases, 10 interictal SPECT were proved wrong after operation and/or invasive EEG and the other 16 were on speculation using PET and ictal EEG. Ictal hyperperfusion was observed in 14 patients in these interictal SPECT. Six ictal studies were found postictal accompanied by contralateral propagation or not. Two patients had dual pathology, and the remaining 2 unknown. Interictal SPECT was done on the 2nd day after ictal study(24), the 3rd day (18), the 4th day(16), the 5th day (23). Four among 24 interictal studies (17%) of the 2nd day and the other 4 among 57 of 3rd to 5th day revealed ictal hyperperfusion on interictal SPECT. Six interictal studies (2.7% among 221) acquired on the indifferent day showed also ictal hyperperfusion. We could suggest that the next day is not desirable for interictal SPECT after ictal study, as ictal hyperperfusion on interictal study confounded more than postictal findings of ictal SPECT in the discrete localization than reassuring ictal study.

  17. Thallium-201 single photon emission computed tomography (SPECT) in patients with Duchenne's progressive muscular dystrophy. A histopathologic correlation study

    International Nuclear Information System (INIS)

    Nishimura, Toru; Yanagisawa, Atsuo; Sakata, Konomi; Shimoyama, Katsuya; Yoshino, Hideaki; Ishikawa, Kyozo; Sakata, Hitomi; Ishihara, Tadayuki

    2001-01-01

    The pathomorphologic mechanism responsible for abnormal perfusion imaging during thallium-201 myocardial single photon emission computed tomography ( 201 Tl-SPECT) in patients with Duchenne's progressive muscular dystrophy (DMD) was investigated. Hearts from 7 patients with DMD were evaluated histopathologically at autopsy and the results correlated with findings on initial and delayed resting 201 Tl-SPECT images. The location of segments with perfusion defects correlated with the histopathologically abnormal segments in the hearts. Both the extent and degree of myocardial fibrosis were severe, especially in the posterolateral segment of the left ventricle. Severe transmural fibrosis and severe fatty infiltration were common in segments with perfusion defects. In areas of redistribution, the degree of fibrosis appeared to be greater than in areas of normal perfusion; and intermuscular edema was prominent. Thus, the degree and extent of perfusion defects detected by 201 Tl-SPECT were compatible with the histopathology. The presence of the redistribution phenomenon may indicate ongoing fibrosis. Initial and delayed resting 201 Tl-SPECT images can predict the site and progress of myocardial degeneration in patients with DMD. (author)

  18. Applications of the Preclinical Molecular Imaging in Biomedicine: Gene Therapy

    International Nuclear Information System (INIS)

    Collantes, M.; Peñuelas, I.

    2014-01-01

    Gene therapy constitutes a promising option for efficient and targeted treatment of several inherited disorders. Imaging techniques using ionizing radiation as PET or SPECT are used for non-invasive monitoring of the distribution and kinetics of vector-mediated gene expression. In this review the main reporter gene/reporter probe strategies are summarized, as well as the contribution of preclinical models to the development of this new imaging modality previously to its application in clinical arena. [es

  19. Effect of Previous Irradiation on Vascular Thrombosis of Microsurgical Anastomosis: A Preclinical Study in Rats

    Science.gov (United States)

    Gallardo-Calero, Irene; López-Fernández, Alba; Romagosa, Cleofe; Vergés, Ramona; Aguirre-Canyadell, Marius; Soldado, Francisco; Velez, Roberto

    2016-01-01

    Background: The objective of the present investigation was to compare the effect of neoadjuvant irradiation on the microvascular anastomosis in cervical bundle using an experimental model in rats. Methods: One hundred forty male Sprague–Dawley rats were allocated into 4 groups: group I, control, arterial microanastomosis; group II, control, venous microanastomosis; group III, arterial microanastomosis with previous irradiation (20 Gy); and group IV, venous microanastomosis with previous irradiation (20 Gy). Clinical parameters, technical values of anastomosis, patency, and histopathological parameters were evaluated. Results: Irradiated groups (III and IV) and vein anastomosis groups (II and IV) showed significantly increased technical difficulties. Group IV showed significantly reduced patency rates (7/35) when compared with the control group (0/35). Radiotherapy significantly decreased the patency rates of the vein (7/35) when compared with the artery (1/35). Groups III and IV showed significantly reduced number of endothelial cells and also showed the presence of intimal thickening and adventitial fibrosis as compared with the control group. Conclusion: Neoadjuvant radiotherapy reduces the viability of the venous anastomosis in a preclinical rat model with a significant increase in the incidence of vein thrombosis. PMID:27975009

  20. Preclinical studies on [{sup 11}C]MPDX for mapping adenosine A{sub 1} receptors by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ishiwata, Kiichi; Kimura, Yuichi; Oda, Keiichi; Kawamura, Kazunori; Ishii, Kenji; Senda, Michio [Tokyo Metropolitan Inst. of Gerontology (Japan). Positron Medical Center; Nariai, Tadashi; Wakabayashi, Shinichi [Tokyo Medical and Dental Univ. (Japan). School of Medicine; Shimada, Junichi [Kyowa Hakko Kogyo Co. Ltd., Tokyo (Japan). Pharmaceutical Research Inst.

    2002-09-01

    In previous in vivo studies with mice, rats and cats, we have demonstrated that [{sup 11}C]MPDX ([1-methyl-{sup 11}C]8-dicyclopropylmethyl-1-methyl-3-propylxanthine) is a potential radioligand for mapping adenosine A{sub 1} receptors of the brain by positron emission tomography (PET). In the present study, we performed a preclinical study. The radiation absorbed-dose by [{sup 11}C]MPDX in humans estimated from the tissue distribution in mice was low enough for clinical use, and the acute toxicity and mutagenicity of MPDX were not found. The monkey brain was clearly visualized by PET with [{sup 11}C]MPDX. We have concluded that [{sup 11}C]MPDX is suitable for mapping adenosine A{sub 1} receptors in the human brain by PET. (author)

  1. A systematic review of methodology applied during preclinical anesthetic neurotoxicity studies: important issues and lessons relevant to the design of future clinical research.

    Science.gov (United States)

    Disma, Nicola; Mondardini, Maria C; Terrando, Niccolò; Absalom, Anthony R; Bilotta, Federico

    2016-01-01

    Preclinical evidence suggests that anesthetic agents harm the developing brain thereby causing long-term neurocognitive impairments. It is not clear if these findings apply to humans, and retrospective epidemiological studies thus far have failed to show definitive evidence that anesthetic agents are harmful to the developing human brain. The aim of this systematic review was to summarize the preclinical studies published over the past decade, with a focus on methodological issues, to facilitate the comparison between different preclinical studies and inform better design of future trials. The literature search identified 941 articles related to the topic of neurotoxicity. As the primary aim of this systematic review was to compare methodologies applied in animal studies to inform future trials, we excluded a priori all articles focused on putative mechanism of neurotoxicity and the neuroprotective agents. Forty-seven preclinical studies were finally included in this review. Methods used in these studies were highly heterogeneous-animals were exposed to anesthetic agents at different developmental stages, in various doses and in various combinations with other drugs, and overall showed diverse toxicity profiles. Physiological monitoring and maintenance of physiological homeostasis was variable and the use of cognitive tests was generally limited to assessment of specific brain areas, with restricted translational relevance to humans. Comparison between studies is thus complicated by this heterogeneous methodology and the relevance of the combined body of literature to humans remains uncertain. Future preclinical studies should use better standardized methodologies to facilitate transferability of findings from preclinical into clinical science. © 2015 John Wiley & Sons Ltd.

  2. [Classification of results of studying blood plasma with laser correlation spectroscopy based on semiotics of preclinical and clinical states].

    Science.gov (United States)

    Ternovoĭ, K S; Kryzhanovskiĭ, G N; Musiĭchuk, Iu I; Noskin, L A; Klopov, N V; Noskin, V A; Starodub, N F

    1998-01-01

    The usage of laser correlation spectroscopy for verification of preclinical and clinical states is substantiated. Developed "semiotic" classifier for solving the problems of preclinical and clinical states is presented. The substantiation of biological algorithms as well as the mathematical support and software for the proposed classifier for the data of laser correlation spectroscopy of blood plasma are presented.

  3. Preclinical characterization of three transient receptor potential vanilloid receptor 1 antagonists for early use in human intradermal microdose analgesic studies.

    Science.gov (United States)

    Sjögren, E; Halldin, M M; Stålberg, O; Sundgren-Andersson, A K

    2018-05-01

    The transient receptor potential vanilloid receptor 1 (TRPV1) is a nonselective cation channel involved in the mediation of peripheral pain to the central nervous system. As such, the TRPV1 is an accessible molecular target that lends itself well to the understanding of nociceptive signalling. This study encompasses preclinical investigations of three molecules with the prospect to establish them as suitable analgesic model compounds in human intradermal pain relief studies. The inhibitory effectiveness was evaluated by means of in vitro assays, TRPV1 expressing Chinese hamster ovary cells (CHO-K1) and rat dorsal root ganglion cultures in fluorescent imaging plate reader and whole cell patch clamp systems, as well as in vivo by capsaicin-evoked pain-related behavioural response studies in rat. Secondary pharmacology, pharmacokinetics and preclinical safety were also assessed. In vitro, all three compounds were effective at inhibiting capsaicin-activated TRPV1. The concentration producing 50% inhibition (IC 50 ) determined was in the range of 3-32 nmol/L and 10-501 nmol/L using CHO-K1 and dorsal root ganglion cultures, respectively. In vivo, all compounds showed dose-dependent reduction in capsaicin-evoked pain-related behavioural responses in rat. None of the three compounds displayed any significant activity on any of the secondary targets tested. The compounds were also shown to be safe from a toxicological, drug metabolism and pharmacokinetic perspective, for usage in microgram doses in the human skin. The investigated model compounds displayed ideal compound characteristics as pharmacological and translational tools to address efficacy on the human native TRPV1 target in human skin in situ. This work details the pharmaceutical work-up of three TRPV1-active investigational compounds, to obtain regulatory approval, for subsequent use in humans. This fast and cost-effective preclinical development path may impact research beyond the pain management area, as

  4. Evaluation of the diagnostic performance of SPECT coupled to tomodensitometry (SPECT-CT) in the daily practice of bone scintigraphy at the Nuclear Medical station of Nancy

    International Nuclear Information System (INIS)

    Netter, F.; Journo, A.; Mayer, J.C.; Grandpierre, S.; Daragon, N.; Karcher, G.; Olivier, P.; Scigliano, S.

    2008-01-01

    Objective: The purpose of our study was to evaluate the diagnostic performance of SPECT coupled to computed axial tomography (SPECT- CT) in our daily practice of bone scintigraphy. Subjects and methods: SPECT- CT obtained as a complement to the planar bone scintigraphy in 39 patients were studied. Each type of image was retrospectively read by two different observers: a nuclear medicine physician who was unaware of SPECT- CT results analysed planar bone scintigraphy, a second one who was unaware of planar bone scintigraphy results analysed SPECT- CT images. In this population of patients, 17 patients were addressed in an oncologic setting. The 22 other patients were addressed for pain of indeterminate origin without neoplastic context. Results: In 13% of the cases, SPECT- CT specified the precise location of increased uptake foci seen on planar bone scintigraphy. In 38% of cases, SPECT- CT confirmed a diagnosis suspected by the planar bone scintigraphy. In 10% of cases, SPECT- CT established a diagnosis that was uncertain with planar bone scintigraphy. In 26% of cases, SPECT- CT brought no additional information. Finally in 3% of cases, SPECT- CT proved to be more sensitive than planar images. Conclusion: Our study demonstrates the utility of SPECT- CT in the daily practice of bone scintigraphy, this complementary imaging study benefited to 74% of our patients. (authors)

  5. [Preclinical study of immunocorrection action of the sum of active substances of Coluria geoides (Pall.) Ledeb. (Rosaceae)].

    Science.gov (United States)

    Dutova, S V; Karpova, M R; Myadelets, M A; Myasnaya, N V; Sherstoboev, E Yu

    2015-01-01

    A preclinical study of the immunocorrection action of the sum of active substances isolated from ethereal-oil plants Coluria geoides (Pall.) Ledeb. (Rosaceae family) with respect to experimental immunodeficiency showed that preparations relieve symptoms of immunodeficiency caused by the administration of cyclophosphan: suppressed synthesis of anti-erythrocyte antibodies (agglutinine) and proliferative processes in the spleen. Under the influence of C. geoides preparations, the absolute numbers of cariocytes and antibody forming cells in spleen significantly increased (compared to the group of animals with experimental immunodeficiency) and in some cases reached the background level. The drugs studied produced a more pronounced stimulating effect on the synthesis of specific immunoglobulins and proliferation of antibody forming cells of spleen as compared to the effect of Echinacea tincture. Preparation C-2 (extract from underground organs and grass of C. geoides obtained by percolation method with 70% ethanol) is most promising for in-depth research and the development of new effective drugs with immunocorrecting properties.

  6. Brain perfusion SPECT in the mouse: normal pattern according to gender and age.

    Science.gov (United States)

    Apostolova, Ivayla; Wunder, Andreas; Dirnagl, Ulrich; Michel, Roger; Stemmer, Nina; Lukas, Mathias; Derlin, Thorsten; Gregor-Mamoudou, Betina; Goldschmidt, Jürgen; Brenner, Winfried; Buchert, Ralph

    2012-12-01

    Regional cerebral blood flow (rCBF) is a useful surrogate marker of neuronal activity and a parameter of primary interest in the diagnosis of many diseases. The increasing use of mouse models spawns the demand for in vivo measurement of rCBF in the mouse. Small animal SPECT provides excellent spatial resolution at adequate sensitivity and is therefore a promising tool for imaging the mouse brain. This study evaluates the feasibility of mouse brain perfusion SPECT and assesses the regional pattern of normal Tc-99m-HMPAO uptake and the impact of age and gender. Whole-brain kinetics was compared between Tc-99m-HMPAO and Tc-99m-ECD using rapid dynamic planar scans in 10 mice. Assessment of the regional uptake pattern was restricted to the more suitable tracer, HMPAO. Two HMPAO SPECTs were performed in 18 juvenile mice aged 7.5 ± 1.5weeks, and in the same animals at young adulthood, 19.1 ± 4.0 weeks (nanoSPECT/CTplus, general purpose mouse apertures: 1.2kcps/MBq, 0.7mm FWHM). The 3-D MRI Digital Atlas Database of an adult C57BL/6J mouse brain was used for region-of-interest (ROI) analysis. SPECT images were stereotactically normalized using SPM8 and a custom made, left-right symmetric HMPAO template in atlas space. For testing lateral asymmetry, each SPECT was left-right flipped prior to stereotactical normalization. Flipped and unflipped SPECTs were compared by paired testing. Peak brain uptake was similar for ECD and HMPAO: 1.8 ± 0.2 and 2.1 ± 0.6 %ID (p=0.357). Washout after the peak was much faster for ECD than for HMPAO: 24 ± 7min vs. 4.6 ± 1.7h (p=0.001). The general linear model for repeated measures with gender as an intersubject factor revealed an increase in relative HMPAO uptake with age in the neocortex (p=0.018) and the hippocampus (p=0.012). A decrease was detected in the midbrain (p=0.025). Lateral asymmetry, with HMPAO uptake larger in the left hemisphere, was detected primarily in the neocortex, both at juvenile age (asymmetry index AI=2.7 ± 1

  7. Electrocardiographic-gated dual-isotope simultaneous acquisition SPECT using 18F-FDG and 99mTc-sestamibi to assess myocardial viability and function in a single study

    International Nuclear Information System (INIS)

    Matsunari, Ichiro; Matsudaira, Masamichi; Hisada, Kinichi; Kanayama, Sugako; Yoneyama, Tatsuya; Nakajima, Kenichi; Taki, Junichi; Tonami, Norihisa; Nekolla, Stephan G.

    2005-01-01

    Dual-isotope simultaneous acquisition single-photon emission computed tomography (DISA SPECT) with 18 F-fluorodeoxyglucose (FDG) and 99m Tc-sestamibi appears attractive for the detection of viable myocardium because it permits simultaneous assessment of glucose utilisation and perfusion. Another potential benefit of this approach is that the measurement of left ventricular (LV) function may be possible by ECG gating. The aim of this study was to test the hypothesis that both myocardial viability and LV function can be assessed by a single ECG-gated 18 F-FDG/ 99m Tc-sestamibi DISA SPECT study, based on comparison with 18 F-FDG/ 13 N-ammonia positron emission tomography (PET) and magnetic resonance imaging (MRI) as reference techniques. Thirty-three patients with prior myocardial infarction underwent ECG-gated 18 F-FDG/ 99m Tc-sestamibi DISA SPECT and 18 F-FDG/ 13 N-ammonia PET on a single day. Of these, 25 patients also underwent cine-MRI to assess LV function. The LV myocardium was divided into nine regions, and each region was classified as viable or scar using a semiquantitative visual scoring system as well as quantitative analysis. The global and regional LV function measured by gated SPECT was compared with the results of MRI. There was good agreement in respect of viability (90-96%, κ0.74-0.85) between DISA SPECT and PET by either visual or quantitative analysis. Furthermore, although both global and regional LV function measured by gated SPECT agreed with those by MRI, 99m Tc-sestamibi showed a closer correlation with MRI than did 18 F-FDG. In conclusion, ECG-gated DISA SPECT provides information on myocardial viability, as well as global and regional LV function, similar to that obtained by PET and MRI. (orig.)

  8. Design Studies of a CZT-based Detector Combined with a Pixel-Geometry-Matching Collimator for SPECT Imaging.

    Science.gov (United States)

    Weng, Fenghua; Bagchi, Srijeeta; Huang, Qiu; Seo, Youngho

    2013-10-01

    Single Photon Emission Computed Tomography (SPECT) suffers limited efficiency due to the need for collimators. Collimator properties largely decide the data statistics and image quality. Various materials and configurations of collimators have been investigated in many years. The main thrust of our study is to evaluate the design of pixel-geometry-matching collimators to investigate their potential performances using Geant4 Monte Carlo simulations. Here, a pixel-geometry-matching collimator is defined as a collimator which is divided into the same number of pixels as the detector's and the center of each pixel in the collimator is a one-to-one correspondence to that in the detector. The detector is made of Cadmium Zinc Telluride (CZT), which is one of the most promising materials for applications to detect hard X-rays and γ -rays due to its ability to obtain good energy resolution and high light output at room temperature. For our current project, we have designed a large-area, CZT-based gamma camera (20.192 cm×20.192 cm) with a small pixel pitch (1.60 mm). The detector is pixelated and hence the intrinsic resolution can be as small as the size of the pixel. Materials of collimator, collimator hole geometry, detection efficiency, and spatial resolution of the CZT detector combined with the pixel-matching collimator were calculated and analyzed under different conditions. From the simulation studies, we found that such a camera using rectangular holes has promising imaging characteristics in terms of spatial resolution, detection efficiency, and energy resolution.

  9. Analysis of machine perfusion benefits in kidney grafts: a preclinical study

    Directory of Open Access Journals (Sweden)

    Eugene Michel

    2011-01-01

    Full Text Available Abstract Background Machine perfusion (MP has potential benefits for marginal organs such as from deceased from cardiac death donors (DCD. However, there is still no consensus on MP benefits. We aimed to determine machine perfusion benefits on kidney grafts. Methods We evaluated kidney grafts preserved in ViaspanUW or KPS solutions either by CS or MP, in a DCD pig model (60 min warm ischemia + 24 h hypothermic preservation. Endpoints were: function recovery, quality of function during follow up (3 month, inflammation, fibrosis, animal survival. Results ViaspanUW-CS animals did not recover function, while in other groups early follow up showed similar values for kidney function. Alanine peptidase and β-NAG activities in the urine were higher in CS than in MP groups. Oxydative stress was lower in KPS-MP animals. Histology was improved by MP over CS. Survival was 0% in ViaspanUW-CS and 60% in other groups. Chronic inflammation, epithelial-to-mesenchymal transition and fibrosis were lowest in KPS-MP, followed by KPS-CS and ViaspanUW-MP. Conclusions With ViaspanUW, effects of MP are obvious as only MP kidney recovered function and allowed survival. With KPS, the benefits of MP over CS are not directly obvious in the early follow up period and only histological analysis, urinary tubular enzymes and red/ox status was discriminating. Chronic follow-up was more conclusive, with a clear superiority of MP over CS, independently of the solution used. KPS was proven superior to ViaspanUW in each preservation method in terms of function and outcome. In our pre-clinical animal model of DCD transplantation, MP offers critical benefits.

  10. Anti-Inflammatory Strategies in Intrahepatic Islet Transplantation: A Comparative Study in Preclinical Models.

    Science.gov (United States)

    Citro, Antonio; Cantarelli, Elisa; Pellegrini, Silvia; Dugnani, Erica; Piemonti, Lorenzo

    2018-02-01

    The identification of pathway(s) playing a pivotal role in peritransplant detrimental inflammatory events represents the crucial step toward a better management and outcome of pancreatic islet transplanted patients. Recently, we selected the CXCR1/2 inhibition as a relevant strategy in enhancing pancreatic islet survival after transplantation. Here, the most clinically used anti-inflammatory compounds (IL1-receptor antagonist, steroids, and TNF-α inhibitor) alone or in combination with a CXCR1/2 inhibitor were evaluated in their ability to improve engraftment or delay graft rejection. To rule out bias related to transplantation site, we used well-established preclinical syngeneic (250 C57BL/6 equivalent islets in C57BL/6) and allogeneic (400 Balb/c equivalent islets in C57BL6) intrahepatic islet transplantation platforms. In mice, we confirmed that targeting the CXCR1/2 pathway is crucial in preserving islet function and improving engraftment. In the allogeneic setting, CXCR1/2 inhibitor alone could reduce the overall recruitment of transplant-induced leukocytes and significantly prolong the time to graft rejection both as a single agent and in combination with immunosuppression. No other anti-inflammatory compounds tested (IL1-receptor antagonist, steroids, and TNF-α inhibitor) alone or in combination with CXCR1/2 inhibitor improve islet engraftment and significantly delay graft rejection in the presence of MMF + FK-506 immunosuppressive treatment. These findings indicate that only the CXCR1/2-mediated axis plays a crucial role in controlling the islet damage and should be a target for intervention to improve the efficiency of islet transplantation.

  11. Feature tracking CMR reveals abnormal strain in preclinical arrhythmogenic right ventricular dysplasia/ cardiomyopathy: a multisoftware feasibility and clinical implementation study.

    Science.gov (United States)

    Bourfiss, Mimount; Vigneault, Davis M; Aliyari Ghasebeh, Mounes; Murray, Brittney; James, Cynthia A; Tichnell, Crystal; Mohamed Hoesein, Firdaus A; Zimmerman, Stefan L; Kamel, Ihab R; Calkins, Hugh; Tandri, Harikrishna; Velthuis, Birgitta K; Bluemke, David A; Te Riele, Anneline S J M

    2017-09-01

    Regional right ventricular (RV) dysfunction is the hallmark of Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy (ARVD/C), but is currently only qualitatively evaluated in the clinical setting. Feature Tracking Cardiovascular Magnetic Resonance (FT-CMR) is a novel quantitative method that uses cine CMR to calculate strain values. However, most prior FT-CMR studies in ARVD/C have focused on global RV strain using different software methods, complicating implementation of FT-CMR in clinical practice. We aimed to assess the clinical value of global and regional strain using FT-CMR in ARVD/C and to determine differences between commercially available FT-CMR software packages. We analyzed cine CMR images of 110 subjects (39 overt ARVD/C [mutation+/phenotype+], 40 preclinical ARVD/C [mutation+/phenotype-] and 31 control) for global and regional (subtricuspid, anterior, apical) RV strain in the horizontal longitudinal axis using four FT-CMR software methods (Multimodality Tissue Tracking, TomTec, Medis and Circle Cardiovascular Imaging). Intersoftware agreement was assessed using Bland Altman plots. For global strain, all methods showed reduced strain in overt ARVD/C patients compared to control subjects (p  0.275). For regional strain, overt ARVD/C patients showed reduced strain compared to control subjects in all segments which reached statistical significance in the subtricuspid region for all software methods (p < 0.037), in the anterior wall for two methods (p < 0.005) and in the apex for one method (p = 0.012). Preclinical subjects showed abnormal subtricuspid strain compared to control subjects using one of the software methods (p = 0.009). Agreement between software methods for absolute strain values was low (Intraclass Correlation Coefficient = 0.373). Despite large intersoftware variability of FT-CMR derived strain values, all four software methods distinguished overt ARVD/C patients from control subjects by both global and subtricuspid

  12. Bioengineered Temporomandibular Joint Disk Implants: Study Protocol for a Two-Phase Exploratory Randomized Preclinical Pilot Trial in 18 Black Merino Sheep (TEMPOJIMS)

    Science.gov (United States)

    Monje, Florencio Gil; González-García, Raúl; Little, Christopher B; Mónico, Lisete; Pinho, Mário; Santos, Fábio Abade; Carrapiço, Belmira; Gonçalves, Sandra Cavaco; Morouço, Pedro; Alves, Nuno; Moura, Carla; Wang, Yadong; Jeffries, Eric; Gao, Jin; Sousa, Rita; Neto, Lia Lucas; Caldeira, Daniel; Salvado, Francisco

    2017-01-01

    Background Preclinical trials are essential to test efficacious options to substitute the temporomandibular joint (TMJ) disk. The contemporary absence of an ideal treatment for patients with severe TMJ disorders can be related to difficulties concerning the appropriate study design to conduct preclinical trials in the TMJ field. These difficulties can be associated with the use of heterogeneous animal models, the use of the contralateral TMJ as control, the absence of rigorous randomized controlled preclinical trials with blinded outcomes assessors, and difficulties involving multidisciplinary teams. Objective This study aims to develop a new, reproducible, and effective study design for preclinical research in the TMJ domain, obtaining rigorous data related to (1) identify the impact of bilateral discectomy in black Merino sheep, (2) identify the impact of bilateral discopexy in black Merino sheep, and (3) identify the impact of three different bioengineering TMJ discs in black Merino sheep. Methods A two-phase exploratory randomized controlled preclinical trial with blinded outcomes is proposed. In the first phase, nine sheep are randomized into three different surgical bilateral procedures: bilateral discectomy, bilateral discopexy, and sham surgery. In the second phase, nine sheep are randomized to bilaterally test three different TMJ bioengineering disk implants. The primary outcome is the histological gradation of TMJ. Secondary outcomes are imaging changes, absolute masticatory time, ruminant time per cycle, ruminant kinetics, ruminant area, and sheep weight. Results Previous preclinical studies in this field have used the contralateral unoperated side as a control, different animal models ranging from mice to a canine model, with nonrandomized, nonblinded and uncontrolled study designs and limited outcomes measures. The main goal of this exploratory preclinical protocol is to set a new standard for future preclinical trials in oromaxillofacial surgery

  13. Cranberries and Cancer: An Update of Preclinical Studies Evaluating the Cancer Inhibitory Potential of Cranberry and Cranberry Derived Constituents

    Directory of Open Access Journals (Sweden)

    Katherine M. Weh

    2016-08-01

    Full Text Available Cranberries are rich in bioactive constituents reported to influence a variety of health benefits, ranging from improved immune function and decreased infections to reduced cardiovascular disease and more recently cancer inhibition. A review of cranberry research targeting cancer revealed positive effects of cranberries or cranberry derived constituents against 17 different cancers utilizing a variety of in vitro techniques, whereas in vivo studies supported the inhibitory action of cranberries toward cancers of the esophagus, stomach, colon, bladder, prostate, glioblastoma and lymphoma. Mechanisms of cranberry-linked cancer inhibition include cellular death induction via apoptosis, necrosis and autophagy; reduction of cellular proliferation; alterations in reactive oxygen species; and modification of cytokine and signal transduction pathways. Given the emerging positive preclinical effects of cranberries, future clinical directions targeting cancer or premalignancy in high risk cohorts should be considered.

  14. Advances in breast cancer treatment and prevention: preclinical studies on aromatase inhibitors and new selective estrogen receptor modulators (SERMs)

    International Nuclear Information System (INIS)

    Schiff, Rachel; Chamness, Gary C; Brown, Powel H

    2003-01-01

    Intensive basic and clinical research over the past 20 years has yielded crucial molecular understanding into how estrogen and the estrogen receptor act to regulate breast cancer and has led to the development of more effective, less toxic, and safer hormonal therapy agents for breast cancer management and prevention. Selective potent aromatase inhibitors are now challenging the hitherto gold standard of hormonal therapy, the selective estrogen-receptor modulator tamoxifen. Furthermore, new selective estrogen-receptor modulators such as arzoxifene, currently under clinical development, offer the possibility of selecting one with a more ideal pharmacological profile for treatment and prevention of breast cancer. Two recent studies in preclinical model systems that evaluate mechanisms of action of these new drugs and suggestions about their optimal clinical use are discussed

  15. A new mathematical approach for the estimation of the AUC and its variability under different experimental designs in preclinical studies.

    Science.gov (United States)

    Navarro-Fontestad, Carmen; González-Álvarez, Isabel; Fernández-Teruel, Carlos; Bermejo, Marival; Casabó, Vicente Germán

    2012-01-01

    The aim of the present work was to develop a new mathematical method for estimating the area under the curve (AUC) and its variability that could be applied in different preclinical experimental designs and amenable to be implemented in standard calculation worksheets. In order to assess the usefulness of the new approach, different experimental scenarios were studied and the results were compared with those obtained with commonly used software: WinNonlin® and Phoenix WinNonlin®. The results do not show statistical differences among the AUC values obtained by both procedures, but the new method appears to be a better estimator of the AUC standard error, measured as the coverage of 95% confidence interval. In this way, the new proposed method demonstrates to be as useful as WinNonlin® software when it was applicable. Copyright © 2011 John Wiley & Sons, Ltd.

  16. SPECT in psychiatry; Die Bedeutung der Hirn-SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Kasper, S [Universitaetsklinik fuer Psychiatrie, Wien (Austria); Gruenwald, F [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin; Danos, P [Psychiatrische Universitaetsklinik, Bonn (Germany); Walter, H [Universitaetsklinik fuer Psychiatrie, Wien (Austria); Klemm, E [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin; Bruecke, T [Universitaetsklinik fuer Neurologie, Wien (Austria); Podreka, I [Universitaetsklinik fuer Neurologie, Wien (Austria); Biersack, H J [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin

    1994-10-01

    In the last fifteen years different attempts have been undertaken to understand the biological basis of major psychiatric disorders. One important tool to determine patterns of brain dysfunction is single emission computed tomography (SPECT). Whereas SPECT investigations are already a valuable diagnostic instrument for the diagnosis of dementia of the Alzheimer Type (DAT) there have not been consistent findings that can be referred to as specific for any other particular psychiatric diagnostic entity. Nevertheless, SPECT studies have been able to demonstrate evidence of brain dysfunction in patients with schizophrenia, depression, anxiety disorders, and substance abuse in which other methods showed no clear abnormality of brain function. Our manuscript reviews the data which are currently available in the literature and stresses the need for further studies, especially for prediction and monitoring psychiatric treatment modalities. (orig.) [Deutsch] In den vergangenen 15 Jahren wurde durch verschiedene methodologische Ansaetze versucht, die biologischen Ursachen psychiatrischer Erkrankungen naeher zu erforschen. Als eine bedeutende Methode hat sich dabei die Single-Photonen-Emissions-Computertomographie (SPECT) herausgestellt. Waehrend die SPECT-Untersuchungen bereits Eingang in die Routinediagnostik bei Demenzen vom Alzheimer-Typ gefunden haben, konnten fuer weitere psychiatrische Erkrankungen noch keine eindeutigen Befunde etabliert werden. Mit der SPECT-Methode ist es jedoch gelungen, funktionelle Veraenderungen des Gehirns von psychiatrischen Erkrankungen darzustellen, wie z.B. Schizophrenie, Depression, Angsterkrankungen bzw. Substanzmissbrauch. In Forschungsprotokollen wird durch die SPECT-Methode versucht, abzuklaeren, inwieweit es moeglich ist, innerhalb der Erkrankungsentitaeten psychiatrischer Erkrankungen oder auch diese uebergreifend eine Subklassifizierung zu finden und evtl. Gehirnsysteme ausfindig zu machen, die mit einer spezifischen

  17. Noninvasive evaluation of ischemic stroke with SPECT

    International Nuclear Information System (INIS)

    Gomez, C.R.; Malik, M.M.; Gomez, S.M.; Wingkun, E.C.

    1988-01-01

    Technetium Tc 99m DTPA single photon emission computerized tomography (SPECT) brain scans of 20 patients with acute ischemic stroke were reviewed retrospectively and compared with clinical and radiologic (CT) data. Fourteen of the patients had abnormal SPECT studies. The abnormal findings were demonstrated by static views in eight patients, by the flow study in one patient, and by both sets of images in the other five patients. All abnormalities correlated with the clinical syndrome of presentation, and only two of the patients had no corresponding lesions on CT. Of the six patients with normal SPECT scans, two had abnormal CT studies, and in the other four, no lesions were shown at all. The ability of /sup 99m/Tc DTPA SPECT to display cerebral infarctions appears to be, at best, comparable to that of CT. SPECT also provides qualitative information regarding flow dynamics in the affected hemisphere of some patients (6/20 in our review). This, we believe, represents the objective demonstration of the preexisting insufficient collateral flow in the hemisphere at risk for ischemic stroke

  18. The consequences of a new software package for the quantification of gated-SPECT myocardial perfusion studies

    International Nuclear Information System (INIS)

    Veen, Berlinda J. van der; Dibbets-Schneider, Petra; Stokkel, Marcel P.M.; Scholte, Arthur J.

    2010-01-01

    Semiquantitative analysis of myocardial perfusion scintigraphy (MPS) has reduced inter- and intraobserver variability, and enables researchers to compare parameters in the same patient over time, or between groups of patients. There are several software packages available that are designed to process MPS data and quantify parameters. In this study the performances of two systems, quantitative gated SPECT (QGS) and 4D-MSPECT, in the processing of clinical patient data and phantom data were compared. The clinical MPS data of 148 consecutive patients were analysed using QGS and 4D-MSPECT to determine the end-diastolic volume, end-systolic volume and left ventricular ejection fraction. Patients were divided into groups based on gender, body mass index, heart size, stressor type and defect type. The AGATE dynamic heart phantom was used to provide reference values for the left ventricular ejection fraction. Although the correlations were excellent (correlation coefficients 0.886 to 0.980) for all parameters, significant differences (p < 0.001) were found between the systems. Bland-Altman plots indicated that 4D-MSPECT provided overall higher values of all parameters than QGS. These differences between the systems were not significant in patients with a small heart (end-diastolic volume <70 ml). Other clinical factors had no direct influence on the relationship. Additionally, the phantom data indicated good linear responses of both systems. The discrepancies between these software packages were clinically relevant, and influenced by heart size. The possibility of such discrepancies should be taken into account when a new quantitative software system is introduced, or when multiple software systems are used in the same institution. (orig.)

  19. Changes in cerebral blood flow after cognitive behavior therapy in patients with panic disorder: a SPECT study

    Directory of Open Access Journals (Sweden)

    Seo HJ

    2014-04-01

    Full Text Available Ho-Jun Seo,1 Young Hee Choi,2 Yong-An Chung,3 Wangku Rho,1 Jeong-Ho Chae11Department of Psychiatry, College of Medicine, The Catholic University of Korea, Seoul, South Korea; 2Metta Institute of Cognitive Behavior Therapy, Seoul, South Korea; 3Department of Radiology, Nuclear Medicine, College of Medicine, The Catholic University of Korea, Seoul, South KoreaAim: Inconsistent results continue to be reported in studies that examine the neural correlates of cognitive behavioral therapy (CBT in patients with panic disorder. We examined the changes in regional cerebral blood flow (rCBF associated with the alleviation of anxiety by CBT in panic patients.Methods: The change in rCBF and clinical symptoms before and after CBT were assessed using single photon emission computed tomography and various clinical measures were analyzed.Results: Fourteen subjects who completed CBT showed significant improvements in symptoms on clinical measures, including the Panic and Agoraphobic Scale and the Anxiety Sensitivity Index-Revised. After CBT, increased rCBF was detected in the left postcentral gyrus (BA 43, left precentral gyrus (BA 4, and left inferior frontal gyrus (BA 9 and BA 47, whereas decreased rCBF was detected in the left pons. Correlation analysis of the association between the changes in rCBF and changes in each clinical measure did not show significant results.Conclusion: We found changes in the rCBF associated with the successful completion of CBT. The present findings may help clarify the effects of CBT on changes in brain activity in panic disorder.Keyword: single photon emission computed tomography (SPECT, anxiety, neural correlate, brain activity

  20. [99mTc]/[123I] Simultaneous dual-isotope brain striatum phantom SPECT study: preparing for simultaneous [99mTc]TRODAT-1/[123I]-IBZM pre- and post-synaptic dopamine imaging

    International Nuclear Information System (INIS)

    Kao, PF; Hsu, HT; Tzen, KY; Wey, SP

    2004-01-01

    Introduction: The brain dopamine transporters (DAT) and dopamine D2 receptors are implicated in all kinds of movement disorders. Both sites are also targets for drug treatment, Therefore, brain dopamine system is important in both basic and clinical neurological researches. Kung HF et al. developed [ 99m Tc]TRODAT-l for DAT and [ 123 I]IBZM for D2 receptor SPECT imaging in living human brain. In this work, the possibility of doing [ 99m Tc]TRODAT-1/[ 123 I]IBZM simultaneous dual-isotope SPECT for both DAT/D2 receptor imaging was studied. The SPECT acquisition protocol, the percent of 99m Tc/ 123 I energy cross contamination, and the reproducibility of striatal /background ratios were studied with a striatal phantom to confirm the accuracy of 99m Tc/ 123 I dual-isotope simultaneous SPECT technique. Materials and Methods: In each set of experiment, the 4 striatum (target) chambers and the rest of the brain (background) were filled with solutions containing 99m Tc only, 123 I only, and both isotopes. Several sets of experiment with different target/background ratios were tested. For SPECT image acquisition, a triple-head gamma camera equipp with high resolution fan-beam collimators (Siemens Multi-SPECT3). Energy window settings of a 15% centered window at 140KeV for 99m Tc and a 10% asymmetric window with a lower bound at 159KeV for 123 I were used. After filtered backprojection and Chang's attenuation correction, regions of interest were defined at the bilateral basal ganglia and occipital areas. The reproducibility of counting activity and the different target/background ratios from each isotope were observed. Results: The results of the study revealed that the energy crossed contaminations from I-123 into Tc- 99m and vice verse were 22±12.4 % and 0.4±1.0 %, respectively. The correlation of striatum/background ratios between single isotope and simultaneous was excellent (R2 = 0.99). The success of this simultaneous dual-isotope SPECT technique is suggestive of the

  1. Translational reciprocity: bridging the gap between preclinical studies and clinical treatment of stress effects on the adolescent brain.

    Science.gov (United States)

    Neigh, G N; Ritschel, L A; Kilpela, L S; Harrell, C S; Bourke, C H

    2013-09-26

    The genetic, biological, and environmental backgrounds of an organism fundamentally influence the balance between risk and resilience to stress. Sex, age, and environment transact with responses to trauma in ways that can mitigate or exacerbate the likelihood that post-traumatic stress disorder will develop. Translational approaches to modeling affective disorders in animals will ultimately provide novel treatments and a better understanding of the neurobiological underpinnings behind these debilitating disorders. The extant literature on trauma/stress has focused predominately on limbic and cortical structures that innervate the hypothalamic-pituitary-adrenal axis and influence glucocorticoid-mediated negative feedback. It is through these neuroendocrine pathways that a self-perpetuating fear memory can propagate the long-term effects of early life trauma. Recent work incorporating translational approaches has provided novel pathways that can be influenced by early life stress, such as the glucocorticoid receptor chaperones, including FKBP51. Animal models of stress have differing effects on behavior and endocrine pathways; however, complete models replicating clinical characteristics of risk and resilience have not been rigorously studied. This review discusses a four-factor model that considers the importance of studying both risk and resilience in understanding the developmental response to trauma/stress. Consideration of the multifactorial nature of clinical populations in the design of preclinical models and the application of preclinical findings to clinical treatment approaches comprise the core of translational reciprocity, which is discussed in the context of the four-factor model. Copyright © 2012 IBRO. Published by Elsevier Ltd. All rights reserved.

  2. A comparative study on PET and SPECT image formation systems for a proper scanner choice in a considered PET center

    International Nuclear Information System (INIS)

    Santos, G.R. dos; Oliveira, A. de; Oliveira, C.L. de

    2001-01-01

    Full text: In the last twenty years, the conjunction of technology and research had provided exceptional conditions for improvements on the quality of life, specially on nuclear medicine. In this area, the developed technology is being applied, making available better diagnoses and therapy to a variety of diseases. Since then the short-lived radionuclides were available only in the large physics research centers. The increasing clinical applications have led to the rapid rise in the number of compact cyclotrons throughout the world. All medical cyclotrons currently are suitable for sustaining programs for PET research and clinical application. To date, up to 122 medical cyclotrons have been established worldwide, and Brazil is about to install a new dedicated cyclotron (RDS111 from CTI), to its first PET Center, in Rio de Janeiro. Also the number of scanners worldwide has increased, mainly those based on the positrons emission and annihilation. The better result gotten in the final contrast of the object imposes a comparative study and analysis of the image formation process, either in a system based on a Single Photon Emission Computerized Tomography (SPECT), as well as on Positron Emission Tomography (PET.) This comparative study should at least follow same increasing rates of the new devices with technological advances. That kind of study can be helpful on the decision of what type of scan should be the proper one, to a PET Center, on a specific region. Obviously, many other parameters are involved in that decision, and this discussion and analyses are the main subject of the present work. The objective is to make available a realistic comparative scenario. Many of the new devices have been introduced making progresses. As an example, in the new PET scanners, the reduction of examination time, and the remarkable improvement on the diagnoses based on images. As a consequence, we have a broadening on application, better performance, and making possible the

  3. Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology

    Science.gov (United States)

    Erlandsson, Kjell; Kacperski, Krzysztof; van Gramberg, Dean; Hutton, Brian F.

    2009-05-01

    D-SPECT (Spectrum Dynamics, Israel) is a novel SPECT system for cardiac perfusion studies. Based on CZT detectors, region-centric scanning, high-sensitivity collimators and resolution recovery, it offers potential advantages over conventional systems. A series of measurements were made on a β-version D-SPECT system in order to evaluate its performance in terms of energy resolution, scatter fraction, sensitivity, count rate capability and resolution. Corresponding measurements were also done on a conventional SPECT system (CS) for comparison. The energy resolution of the D-SPECT system at 140 keV was 5.5% (CS: 9.25%), the scatter fraction 30% (CS: 34%), the planar sensitivity 398 s-1 MBq-1 per head (99mTc, 10 cm) (CS: 72 s-1 MBq-1), and the tomographic sensitivity in the heart region was in the range 647-1107 s-1 MBq-1 (CS: 141 s-1 MBq-1). The count rate increased linearly with increasing activity up to 1.44 M s-1. The intrinsic resolution was equal to the pixel size, 2.46 mm (CS: 3.8 mm). The average reconstructed resolution using the standard clinical filter was 12.5 mm (CS: 13.7 mm). The D-SPECT has superior sensitivity to that of a conventional system with similar spatial resolution. It also has excellent energy resolution and count rate characteristics, which should prove useful in dynamic and dual radionuclide studies.

  4. SPECT studies of the dopamine transporters in subclinical and clinical hemi-parkinsonism monkeys with 99Tcm-TRODAT-1

    International Nuclear Information System (INIS)

    Bian Yanzhu; Liu Huaijun; Feng Jue; Wei Qiang; Li Jinfu; Liu Guozhang

    2004-01-01

    Objective: To investigate the values of 99 Tc m -2β-((N,N'-bis (2-mercap-toethyl) ethylene diamino) methyl), 3β-(4-chlorophenyl)tropane, ( 99 Tc m -TRODAT-1) dopamine transporter (DAT) SPECT in diagnosis of subclinical Parkinson's disease. Methods: 4 healthy monkeys without auto-rotation were recruited and were marked as M1, M2, M3, M4 respectively. The whole body scan was done on M1 and M2 after 99 Tc m -TRODAT-1 555 MBq injection of vein. The radioactivity distribution ratio of each organ at various time points was calculated by region of interest (ROI) technique. 99 Tc m -TRODAT-1 SPECT imaging were obtained on M1 and M2 at various time point after 99 Tc m -TRODAT-1 555-740 MBq injection of vein. Striatum/cerebellum radioactivity ratios were calculated by ROI technique on 4 transverse imaging. Striatum/cerebellum radioactivity ratio represents striatum DAT function. Subclinical hemi-parkinsonism monkeys were founded on Ml-M4 by given MPTP 0.3 mg/Kg through right internal carotid artery, Clinical hemi-pakinsonism monkeys were founded on M2-M4 by given MPTP 0.7 mg/Kg through right internal carotid artery for second time. Subclinical and clinical hemi-parkinsonism monkeys were accepted 99 Tc m -TRODAT-1 DAT SPECT, striatum DAT functions were evaluated by ROI technique respectively. Results: The major radioactivity was excreted by the hepatobiliary system. The optimal imaging time for 99m Tc-TRODAT-1 SPECT was 3 hours post injection. In subclinical hemi-parkinsonism monkeys, right striatum DAT function was lower than left (1.33+0.08,1.59+0.07,P 99 Tc m -TRODAT-1 DAT SPECT can explore the subclinical DAT function changes in hemi- parkinsonism monkeys. 99 Tc m -TRODAT-1 DAT SPECT is a useful method for early diagnosis of subclinical PD. Conclusions: 11 C-Raclopride was first synthesised in our country as a D2R PET agent. The striatum D2R functions had no changes in subclinial PD. The striatum D2R functions upregulated in clinial PD. (authors)

  5. Brain SPECT in childhood

    International Nuclear Information System (INIS)

    Tranquart, F.; Saliba, E.; Prunier, C.; Baulieu, F.; Besnard, J.C.; Guilloteau, D.; Baulieu, J.L.

    2001-01-01

    The modalities and the indications of perfusion and neurotransmission SPECT in childhood are presented. The perfusion as well as neurotransmission tracers have not yet authorization for use in children; they have to be used by prescription of magistral preparation or in research protocols. The radioprotection rules have to be strictly respected. The most frequent indication of perfusion SPECT is pharmacologically resistant epilepsy; the ictal SPECT before surgery allows the localization of the epileptogenic focus. Other indications are relevant in the prognosis of neonatal anoxia and encephalitis. In psychiatric disorders, especially in autism, the interest is the physiopathological approach of the brain dysfunctions. The neurotransmission SPECT is emerging as a consequence of the development of new radiotracer, as the dopaminergic system ligands. The decrease of the dopamine D2 receptors in the striatum can be imaged and quantified in the neonate. The lesions of dopamine system seem to be a consequence of the neonatal hypoxia-ischemia and it is predictive of motor sequelae. Brain SPECT should become a routine examination in child neurologic and psychiatric disorders. (authors)

  6. SPECT in patients with cortical visual loss.

    Science.gov (United States)

    Silverman, I E; Galetta, S L; Gray, L G; Moster, M; Atlas, S W; Maurer, A H; Alavi, A

    1993-09-01

    Single-photon emission computed tomography (SPECT) with 99mTc-hexamethylpropyleneamine oxime (HMPAO) was used to investigate changes in cerebral blood flow in seven patients with cortical visual impairment. Traumatic brain injury (TBI) was the cause of cortical damage in two patients, cerebral ischemia in two patients and carbon monoxide (CO) poisoning, status epilepticus and Alzheimer's Disease (AD) each in three separate patients. The SPECT scans of the seven patients were compared to T2-weighted magnetic resonance image (MRI) scans of the brain to determine the correlation between functional and anatomical findings. In six of the seven patients, the qualitative interpretation of the SPECT studies supported the clinical findings (i.e., the visual field defect) by revealing altered regional cerebral blood flow (rCBF) in the appropriate regions of the visual pathway. MR scans in all of the patients, on the other hand, were either normal or disclosed smaller lesions than those detected by SPECT. We conclude that SPECT may reveal altered rCBF in patients with cortical visual impairment of various etiologies, even when MRI studies are normal or nondiagnostic.

  7. A small-animal imaging system capable of multipinhole circular/helical SPECT and parallel-hole SPECT

    International Nuclear Information System (INIS)

    Qian Jianguo; Bradley, Eric L.; Majewski, Stan; Popov, Vladimir; Saha, Margaret S.; Smith, Mark F.; Weisenberger, Andrew G.; Welsh, Robert E.

    2008-01-01

    We have designed and built a small-animal single-photon emission computed tomography (SPECT) imaging system equipped with parallel-hole and multipinhole collimators and capable of circular or helical SPECT. Copper-beryllium parallel-hole collimators suitable for imaging the ∼35 keV photons from the decay of 125 I have been built and installed to achieve useful spatial resolution over a range of object-detector distances and to reduce imaging time on our dual-detector array. To address the resolution limitations in the parallel-hole SPECT and the sensitivity and limited field of view of single-pinhole SPECT, we have incorporated multipinhole circular and helical SPECT in addition to expanding the parallel-hole SPECT capabilities. The pinhole SPECT system is based on a 110 mm diameter circular detector equipped with a pixellated NaI(Tl) scintillator array (1x1x5 mm 3 /pixel). The helical trajectory is accomplished by two stepping motors controlling the rotation of the detector-support gantry and displacement of the animal bed along the axis of rotation of the gantry. Results obtained in SPECT studies of various phantoms show an enlarged field of view, very good resolution and improved sensitivity using multipinhole circular or helical SPECT. Collimators with one, three and five, 1-mm-diameter pinholes have been implemented and compared in these tests. Our objective is to develop a system on which one may readily select a suitable mode of either parallel-hole SPECT or pinhole circular or helical SPECT for a variety of small animal imaging applications

  8. PET/SPECT/CT multimodal imaging in a transgenic mouse model of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Boisgard, R.; Alberini, J.L.; Jego, B.; Siquier, K.; Theze, B.; Guillermet, S.; Tavitian, B. [Service Hospitalier Frederic Joliot, Institut d' Imagerie BioMedicale, CEA, 91 - Orsay (France); Inserm, U803, 91 - Orsay (France)

    2008-02-15

    Background. - In the therapy monitoring of breast cancer, conventional imaging methods include ultrasound, mammography, CT and MRI, which are essentially based on tumor size modifications. However these modifications represent a late consequence of the biological response and fail to differentiate scar or necrotic tissue from residual viable tumoral tissue. Therefore, a current objective is to develop tools able to predict early response to treatment. Positron Emission Tomography (PET) and Single Photon Emission Computerized Tomography (SPECT) are imaging modalities able to provide extremely sensitive quantitative molecular data and are widely used in humans and animals. Results. - Mammary epithelial cells of female transgenic mice expressing the polyoma middle T onco-protein (Py M.T.), undergo four distinct stages of tumour progression, from pre malignant to malignant stages. Stages are identifiable in the mammary tissue and can lead to the development of distant metastases Longitudinal studies by dynamic whole body acquisitions by multimodal imaging including PET, SPECT and Computed Tomography (CT) allow following the tumoral evolution in Py M.T. mice in comparison with the histopathological analysis. At four weeks of age, mammary hyperplasia was identified by histopathology, but no abnormalities were found by palpation or detected by PET with 2-deoxy-2-[{sup 18}F]fluoro-D-glucose. Such as in some human mammary cancers, the sodium iodide sym-porter (N.I.S.) in tumoral mammary epithelial cells is expressed in this mouse model. In order to investigate the expression of N.I.S. in the Py M.T. mice mammary tumours, [{sup 99m}Tc]TcO{sub 4} imaging was performed with a dedicated SPECT/CT system camera (B.I.O.S.P.A.C.E. Gamma Imager/CT). Local uptake of [{sup 99m}Tc]TcO{sub 4} was detected as early as four weeks of age. The efficacy of chemotherapy was evaluated in this mouse model using a conventional regimen (Doxorubicine, 100 mg/ kg) administered weekly from nine to

  9. SPECT in Focal Epilepsies

    Directory of Open Access Journals (Sweden)

    Roderick Duncan

    2000-01-01

    Full Text Available Brain perfusion changes during seizures were first observed in the 1930s. Single Photon Emission Computed Tomography (SPECT was developed in the 1970s, and tracers suitable for the imaging of regional cerebral perfusion (rCP became available in the 1980s. The method was first used to study rCP in the interictal phase, and this showed areas of low perfusion in a proportion of cases, mainly in patients with temporal lobe epilepsies. However, the trapping paradigm of tracers such as hexamethyl propyleneamine oxime (HMPAO provided a practicable method of studying changes in rCP during seizures, and a literature was established in the late 1980s and early 1990s showing a typical sequence of changes during and after seizures of mesial temporal lobe origin; the ictal phase was associated with large increases in perfusion throughout the temporal lobe, with first the lateral, then the mesial temporal lobe becoming hypoperfused in the postictal phase. Activation and inhibition of other structures, such as the basal ganglia and frontal cortex, were also seen. Studies of seizures originating elsewhere in the brain have shown a variety of patterns of change, according to the structures involved. These changes have been used practically to aid the process of localisation of the epileptogenic zone so that epilepsy surgery can be planned.

  10. Use of a collaborative tool to simplify the outsourcing of preclinical safety studies: an insight into the AstraZeneca-Charles River Laboratories strategic relationship.

    Science.gov (United States)

    Martin, Frederic D C; Benjamin, Amanda; MacLean, Ruth; Hollinshead, David M; Landqvist, Claire

    2017-12-01

    In 2012, AstraZeneca entered into a strategic relationship with Charles River Laboratories whereby preclinical safety packages comprising safety pharmacology, toxicology, formulation analysis, in vivo ADME, bioanalysis and pharmacokinetics studies are outsourced. New processes were put in place to ensure seamless workflows with the aim of accelerating the delivery of new medicines to patients. Here, we describe in more detail the AstraZeneca preclinical safety outsourcing model and the way in which a collaborative tool has helped to translate the processes in AstraZeneca and Charles River Laboratories into simpler integrated workflows that are efficient and visible across the two companies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Two-Dimensional High Definition Versus Three-Dimensional Endoscopy in Endonasal Skull Base Surgery: A Comparative Preclinical Study.

    Science.gov (United States)

    Rampinelli, Vittorio; Doglietto, Francesco; Mattavelli, Davide; Qiu, Jimmy; Raffetti, Elena; Schreiber, Alberto; Villaret, Andrea Bolzoni; Kucharczyk, Walter; Donato, Francesco; Fontanella, Marco Maria; Nicolai, Piero

    2017-09-01

    Three-dimensional (3D) endoscopy has been recently introduced in endonasal skull base surgery. Only a relatively limited number of studies have compared it to 2-dimensional, high definition technology. The objective was to compare, in a preclinical setting for endonasal endoscopic surgery, the surgical maneuverability of 2-dimensional, high definition and 3D endoscopy. A group of 68 volunteers, novice and experienced surgeons, were asked to perform 2 tasks, namely simulating grasping and dissection surgical maneuvers, in a model of the nasal cavities. Time to complete the tasks was recorded. A questionnaire to investigate subjective feelings during tasks was filled by each participant. In 25 subjects, the surgeons' movements were continuously tracked by a magnetic-based neuronavigator coupled with dedicated software (ApproachViewer, part of GTx-UHN) and the recorded trajectories were analyzed by comparing jitter, sum of square differences, and funnel index. Total execution time was significantly lower with 3D technology (P < 0.05) in beginners and experts. Questionnaires showed that beginners preferred 3D endoscopy more frequently than experts. A minority (14%) of beginners experienced discomfort with 3D endoscopy. Analysis of jitter showed a trend toward increased effectiveness of surgical maneuvers with 3D endoscopy. Sum of square differences and funnel index analyses documented better values with 3D endoscopy in experts. In a preclinical setting for endonasal skull base surgery, 3D technology appears to confer an advantage in terms of time of execution and precision of surgical maneuvers. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Is lecture dead? A preliminary study of medical students' evaluation of teaching methods in the preclinical curriculum.

    Science.gov (United States)

    Zinski, Anne; Blackwell, Kristina T C Panizzi Woodley; Belue, F Mike; Brooks, William S

    2017-09-22

    To investigate medical students' perceptions of lecture and non-lecture-based instructional methods and compare preferences for use and quantity of each during preclinical training. We administered a survey to first- and second-year undergraduate medical students at the University of Alabama School of Medicine in Birmingham, Alabama, USA aimed to evaluate preferred instructional methods.  Using a cross-sectional study design, Likert scale ratings and student rankings were used to determine preferences among lecture, laboratory, team-based learning, simulation, small group case-based learning, large group case-based learning, patient presentation, and peer teaching. We calculated mean ratings for each instructional method and used chi-square tests to compare proportions of first- and second-year cohorts who ranked each in their top 5 preferred methods. Among participating students, lecture (M=3.6, SD=1.0), team based learning (M=4.2, SD=1.0), simulation (M=4.0, SD=1.0), small group case-based learning (M=3.8, SD=1.0), laboratory (M=3.6, SD=1.0), and patient presentation (M=3.8, SD=0.9) received higher scores than other instructional methods. Overall, second-year students ranked lecture lower (χ 2 (1, N=120) =16.33, p<0.0001) and patient presentation higher (χ 2 (1, N=120) =3.75, p=0.05) than first-year students. While clinically-oriented teaching methods were preferred by second-year medical students, lecture-based instruction was popular among first-year students. Results warrant further investigation to determine the ideal balance of didactic methods in undergraduate medical education, specifically curricula that employ patient-oriented instruction during the second preclinical year.

  13. Cerebral blood flow of patients with age-associated memory impairment and the early stage of Alzheimer`s disease. A study by SPECT using the ARG method

    Energy Technology Data Exchange (ETDEWEB)

    Ishiwata, Akiko; Kitamura, Shin; Nagazumi, Atushi; Terashi, Akiro [Nippon Medical School, Tokyo (Japan)

    1998-04-01

    In order to further understand the pathology of Alzheimer`s disease (AD), we have utilized image analysis in diagnosing the early stages of AD in patients with cognitive disorders. CT and MRI, however, have not been feasible since only atrophy is seen and it is difficult to differentiate the changes in AD from age associated changes. In this study we tried to determine whether regional cerebral blood flow (rCBF) measurements using single photon emission CT (SPECT) are feasible for the early diagnosis of AD. Regional CBF (rCBF) was measured using SPECT in three subject groups: Age-associated memory impairment (AAMI, n=9), mild AD (n=16), and normal aged patients (mean age=68.3; n=20). The subjects were then observed for three years. The region of interest (ROI) for the medial temporal lobe was set at OM-30deg to cover the maximum area of the hippocampus. The absolute values of rCBF in the frontal, temporal, and parietal lobes and the cerebellum were significantly lower in the mild AD subjects than in the normal aged subjects. A significant decrease in rCBF was also seen in the medial temporal lobe in both the AD and the AAMI subjects compared to the normal controls. During the three years of follow up, no cases of dementia were seen in the AAMI subjects. However, there were two patients who appeared to have difficulty in adapting to daily life due to amnesia, one with a decrease in rCBF of the medial temporal lobe on the second SPECT, and the other showing a low rCBF the first time. This study suggests that AAMI subjects may comprise both AD and normal subjects. Therefore a more prospective study is needed. (author)

  14. Cerebral blood flow of patients with age-associated memory impairment and the early stage of Alzheimer's disease. A study by SPECT using the ARG method

    International Nuclear Information System (INIS)

    Ishiwata, Akiko; Kitamura, Shin; Nagazumi, Atushi; Terashi, Akiro

    1998-01-01

    In order to further understand the pathology of Alzheimer's disease (AD), we have utilized image analysis in diagnosing the early stages of AD in patients with cognitive disorders. CT and MRI, however, have not been feasible since only atrophy is seen and it is difficult to differentiate the changes in AD from age associated changes. In this study we tried to determine whether regional cerebral blood flow (rCBF) measurements using single photon emission CT (SPECT) are feasible for the early diagnosis of AD. Regional CBF (rCBF) was measured using SPECT in three subject groups: Age-associated memory impairment (AAMI, n=9), mild AD (n=16), and normal aged patients (mean age=68.3; n=20). The subjects were then observed for three years. The region of interest (ROI) for the medial temporal lobe was set at OM-30deg to cover the maximum area of the hippocampus. The absolute values of rCBF in the frontal, temporal, and parietal lobes and the cerebellum were significantly lower in the mild AD subjects than in the normal aged subjects. A significant decrease in rCBF was also seen in the medial temporal lobe in both the AD and the AAMI subjects compared to the normal controls. During the three years of follow up, no cases of dementia were seen in the AAMI subjects. However, there were two patients who appeared to have difficulty in adapting to daily life due to amnesia, one with a decrease in rCBF of the medial temporal lobe on the second SPECT, and the other showing a low rCBF the first time. This study suggests that AAMI subjects may comprise both AD and normal subjects. Therefore a more prospective study is needed. (author)

  15. Cerebral blood flow of the non-affected brain in patients with malignant brain tumors as studied by SPECT

    International Nuclear Information System (INIS)

    Araki, Yuzo; Imao, Yukinori; Hirata, Toshifumi; Ando, Takashi; Sakai, Noboru; Yamada, Hiroshi

    1990-01-01

    In 40 patients (age range, 20-69 years) receiving radiation and chemotherapy for brain tumors, the mean cerebral blood flow (mCBF) in the non-affected area has been examined by single photon emission CT (SPECT) with Xe-133. Forty volunteers (age range, 25-82 years) served as controls. Although mCBF during external irradiation was transiently increased, it was significantly decreased at 3 months after beginning of external irradiation compared with that in the control group. Factors responsible for the decrease in mCBF were radiation doses, lesion volume, the degree of cerebral atrophy, and age; this was more pronounced when chemotherapy such as ACNU was combined with radiation. A decreased mCBF was independent of intraoperative radiation combined with external radiation and either local or whole brain irradiation. SPECT with Xe-133 was useful in determining minute changes in cerebral blood flow that precedes parenchymal brain damage. (N.K.)

  16. Applications of cerebral SPECT

    Energy Technology Data Exchange (ETDEWEB)

    McArthur, C., E-mail: claire.mcarthur@nhs.net [Department of Neuroradiology, Institute of Neurological Sciences, Glasgow (United Kingdom); Jampana, R.; Patterson, J.; Hadley, D. [Department of Neuroradiology, Institute of Neurological Sciences, Glasgow (United Kingdom)

    2011-07-15

    Single-photon emission computed tomography (SPECT) can provide three-dimensional functional images of the brain following the injection of one of a series of radiopharmaceuticals that crosses the blood-brain barrier and distributes according to cerebral perfusion, neurotransmitter, or cell density. Applications include differentiating between the dementias, evaluating cerebrovascular disease, preoperative localization of epileptogenic foci, diagnosing movement disorders, and evaluation of intracerebral tumours, while also proving a useful research tool. Unlike positronemission tomography (PET), SPECT imaging is widely available and can be performed in any department that has access to a rotating gamma camera. The purpose of this review is to demonstrate the utility of cerebral SPECT and increase awareness of its role in the investigation of neurological and psychiatric disorders.

  17. Ictal cerebral perfusion patterns in partial epilepsy: SPECT subtraction

    International Nuclear Information System (INIS)

    Lee, Hyang Woon; Hong, Seung Bong; Tae, Woo Suk; Kim, Sang Eun; Seo, Dae Won; Jeong, Seung Cheol; Yi, Ji Young; Hong, Seung Chyul

    2000-01-01

    To investigate the various ictal perfusion patterns and find the relationships between clinical factors and different perfusion patterns. Interictal and ictal SPECT and SPECT subtraction were performed in 61 patients with partial epilepsy. Both positive images showing ictal hyperperfusion and negative images revealing ictal hypoperfusion were obtained by SPECT subtraction. The ictal perfusion patterns of subtracted SPECT were classified into focal hyperperfusion, hyperperfusion-plus, combined hyperperfusion-hypoperfusion, and focal hypoperfusion only. The concordance rates with epileptic focus were 91.8% in combined analysis of ictal hyperperfusion and hypoperfusion images of subtracted SPECT, 85.2% in hyperperfusion images only of subtracted SPECT, and 68.9% in conventional ictal SPECT analysis. Ictal hypoperfusion occurred less frequently in temporal lobe epilepsy (TLE) than extratemporal lobe epilepsy. Mesial temporal hyperperfusion alone was seen only in mesial TLE while lateral temporal hyperperfusion alone was observed only in neocortical TLE. Hippocampal sclerosis had much lower incidence of ictal hypoperfusion than any other pathology. Some patients showed ictal hypoperfusion at epileptic focus with ictal hyperperfusion in the neighboring brain regions where ictal discharges propagated. Hypoperfusion as well as hyperperfusion in ictal SPECT should be considered for localizing epileptic focus. Although the mechanism of ictal hypoperfusion could be an intra-ictal early exhaustion of seizure focus or a steal phenomenon by the propagation of ictal discharges to adjacent brain areas, further study is needed to elucidate it.=20

  18. Ictal cerebral perfusion patterns in partial epilepsy: SPECT subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyang Woon; Hong, Seung Bong; Tae, Woo Suk; Kim, Sang Eun; Seo, Dae Won; Jeong, Seung Cheol; Yi, Ji Young; Hong, Seung Chyul [Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)

    2000-06-01

    To investigate the various ictal perfusion patterns and find the relationships between clinical factors and different perfusion patterns. Interictal and ictal SPECT and SPECT subtraction were performed in 61 patients with partial epilepsy. Both positive images showing ictal hyperperfusion and negative images revealing ictal hypoperfusion were obtained by SPECT subtraction. The ictal perfusion patterns of subtracted SPECT were classified into focal hyperperfusion, hyperperfusion-plus, combined hyperperfusion-hypoperfusion, and focal hypoperfusion only. The concordance rates with epileptic focus were 91.8% in combined analysis of ictal hyperperfusion and hypoperfusion images of subtracted SPECT, 85.2% in hyperperfusion images only of subtracted SPECT, and 68.9% in conventional ictal SPECT analysis. Ictal hypoperfusion occurred less frequently in temporal lobe epilepsy (TLE) than extratemporal lobe epilepsy. Mesial temporal hyperperfusion alone was seen only in mesial TLE while lateral temporal hyperperfusion alone was observed only in neocortical TLE. Hippocampal sclerosis had much lower incidence of ictal hypoperfusion than any other pathology. Some patients showed ictal hypoperfusion at epileptic focus with ictal hyperperfusion in the neighboring brain regions where ictal discharges propagated. Hypoperfusion as well as hyperperfusion in ictal SPECT should be considered for localizing epileptic focus. Although the mechanism of ictal hypoperfusion could be an intra-ictal early exhaustion of seizure focus or a steal phenomenon by the propagation of ictal discharges to adjacent brain areas, further study is needed to elucidate it.

  19. The assessment of whole body bone SPECT in oncology

    International Nuclear Information System (INIS)

    Scortechini, Shonika

    2009-01-01

    Full text: Objectives: To assess the significance and practicability of oncology whole body bone SPECT as part of the standard skeletal survey and its impact on the traditional planar whole body bone imaging protocol. Method: Three consenting oncology patients were injected with a standard adult dose of Tc-99m MOP. Delayed Imaging of whole body sweep and SPECT acquisitions were performed on a Siemens Symbia T6. The patient was positioned supine with arms down with a SPECT scan length covering vortex to thighs. SPECT data was reconstructed and a single whole body zipped file created. Normal SPECT slices along with a cine/MIP of the zipped data were created for review. Results: Both image data sets were reviewed to assess if SPECT provided any further diagnostic clinical information not apparent in planer imaging. In our limited review, whole body SPECT did not add extra value to the planar whole body scans performed; it did however demonstrate vertebral involvement with greater resolution. The processing software and system limitations in seamlessly knitting data sets (creating image artefacts) was a major limiting factor in not pursuing further studies. Conclusion: Both imaging techniques offer differing advantages and limitations, however due to image artefact in the triple knitted SPECT approach with current software technology, it cannot be substituted for whole body imaging at this time.

  20. Assessment of viability by quantitative evaluation of 24h-redistribution in 201-thallium myocardial scintigraphy (SPECT): A comparative study versus clinical follow-up after revascularisation

    International Nuclear Information System (INIS)

    Stirner, H.; Spreng, M.; Picker, D.; Pfafferott, C.

    1992-01-01

    Results of regional quantitative assessment of 24h-redistribution in routinely performed Thallium myocardial scintigraphy (SPECT) were compared to findings of coronary angiography/ventriculography and/or echocardiography as well as clinical status 6 months after revascularisation in up to now 34 patients. In respect of positive and negative predictive values evaluation of 24h-redistribution behaves best (81/100%) compared to perfusion and 3h-redistribution alone. Performing an additional 24h-study gives a gain of at least 80% of diagnostic information. (orig.) [de

  1. Regional cerebral blood flow in children with autism spectrum disorders: a quantitative 99mTc-ECD brain SPECT study with statistical parametric mapping evaluation

    Institute of Scientific and Technical Information of China (English)

    YANG Wen-han; JING Jin; XIU Li-juan; CHENG Mu-hua; WANG Xin; BAO Peng; WANG Qing-xiong

    2011-01-01

    Background Autism spectrum disorders (ASD), which include autism, asperger syndrome (AS) and pervasive developmental disorder-not otherwise specified (PDD-NOS), are devastating neurodevelopmental disorders of childhood resulting in deficits in social interaction, repetitive patterns of behaviors, and restricted interests and activities. Single photon emission computed tomography (SPECT) is a common technique used to measure regional cerebral blood flow (rCBF). Several studies have measured rCBF in children with ASD using SPECT, however, findings are discordant. In addition, the majority of subjects used in these studies were autistic. In this study, we aimed to investigate changes in rCBF in children with ASD using SPECT.Methods A Technetium-99m-ethyl cysteinate dimmer (99mTc-ECD) brain SPECT study was performed on an ASD group consisting of 23 children (3 girls and 20 boys; mean age (7.2±3.0) years) who were diagnosed according to Diagnostic and Statistical Manual of Mental Disorders, 4th edition (DSM-Ⅳ) criteria and an age-matched control group with 8children (1 girl and 7 boys, mean age (5.5±2.4) years). Image data were evaluated with Statistical Parametric Mapping,5th version (SPM5). A Student's t test for unpaired data was used to compare rCBF and asymmetry in the autism and corresponding control group. The covariance analysis, taking age as covariance, was performed between the ASD and control group.Results There was a significant reduction in rCBF in the bilateral frontal lobe (frontal poles, arcula frontal gyrus) and the bilateral basal ganglia in the autism group, and a reduction in the bilateral frontal, temporal, parietal, legumina nucleus and cerebellum in the AS group compared to the control. In addition, asymmetry of hemispheric hypoperfusion in the ASD group was observed. Inner-group comparison analysis revealed that rCBF decreased significantly in the bilateral frontal lobe (42.7%), basal nucleus (24.9%) and temporal lobe (22.8%) in the autism

  2. The study of ictal brain SPECT during seizures induced by clonidine and sleep-deprivation in patients with epilepsy

    International Nuclear Information System (INIS)

    Wang Xiaohui; Chen Xuehong; Wang Zhengjiang; Liu Jiangyan; Feng Jianzhong; Ye Jiang; Zhao Li

    2010-01-01

    Objective: To evaluate the feasibility and clinical value of combined clonidine and sleep-deprivation induced seizures for ictal brain SPECT imaging in patients with epilepsy. Methods: Fifty-two epilepsy patients were given oral clonidine plus sleep-deprivation to induce seizures with video-electroencephalogram (VEEG) monitoring. Forty-seven patients were selected as control group, whose seizures were induced by sleep-deprivation only. 99 Tc m -ethylcysteinate dimer (ECD) was injected within 30 s since a clinical sign and/or a typical EEG discharge of epilepsy was recognized. Brain SPECT was performed 30 min after 99 Tc m -ECD injection. χ 2 -test was performed by using software SPSS 10.0. Results: One to two hr after oral intake of clonidine plus sleep-deprivation, 75% (39/52) patients were induced seizures, including 92.3% (36/39) with subclinical seizures and 7.7% (3/39) with clinical seizures. Ictal brain SPECT localized the lesions with high uptake of 99 Tc m -ECD in 37 (94.9%) patients. In control group, 38.3% (18/47) were induced epileptic seizures, including 77.8% (14/18) with subclinical seizures and 22.2% (4/18) with clinical seizures. The induction rate of epileptic seizures in clonidine plus sleep-deprivation group was significantly higher than that of control group (χ 2 = 13.614, P 2 = 1.253, P>0.05). Conclusions: The combination of oral intake of clonidine and sleep-deprivation could increase the induction rate of epileptic seizures and it is effective for epilepsy SPECT imaging. (authors)

  3. Quantification of dopaminergic neurotransmission SPECT studies with 123I-labelled radioligands. A comparison between different imaging systems and data acquisition protocols using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Crespo, Cristina; Aguiar, Pablo; Gallego, Judith; Cot, Albert; Falcon, Carles; Ros, Domenec; Bullich, Santiago; Pareto, Deborah; Sempau, Josep; Lomena, Francisco; Calvino, Francisco; Pavia, Javier

    2008-01-01

    123 I-labelled radioligands are commonly used for single-photon emission computed tomography (SPECT) imaging of the dopaminergic system to study the dopamine transporter binding. The aim of this work was to compare the quantitative capabilities of two different SPECT systems through Monte Carlo (MC) simulation. The SimSET MC code was employed to generate simulated projections of a numerical phantom for two gamma cameras equipped with a parallel and a fan-beam collimator, respectively. A fully 3D iterative reconstruction algorithm was used to compensate for attenuation, the spatially variant point spread function (PSF) and scatter. A post-reconstruction partial volume effect (PVE) compensation was also developed. For both systems, the correction for all degradations and PVE compensation resulted in recovery factors of the theoretical specific uptake ratio (SUR) close to 100%. For a SUR value of 4, the recovered SUR for the parallel imaging system was 33% for a reconstruction without corrections (OSEM), 45% for a reconstruction with attenuation correction (OSEM-A), 56% for a 3D reconstruction with attenuation and PSF corrections (OSEM-AP), 68% for OSEM-AP with scatter correction (OSEM-APS) and 97% for OSEM-APS plus PVE compensation (OSEM-APSV). For the fan-beam imaging system, the recovered SUR was 41% without corrections, 55% for OSEM-A, 65% for OSEM-AP, 75% for OSEM-APS and 102% for OSEM-APSV. Our findings indicate that the correction for degradations increases the quantification accuracy, with PVE compensation playing a major role in the SUR quantification. The proposed methodology allows us to reach similar SUR values for different SPECT systems, thereby allowing a reliable standardisation in multicentric studies. (orig.)

  4. Quantification of dopaminergic neurotransmission SPECT studies with {sup 123}I-labelled radioligands. A comparison between different imaging systems and data acquisition protocols using Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Crespo, Cristina; Aguiar, Pablo [Universitat de Barcelona - IDIBAPS, Unitat de Biofisica i Bioenginyeria, Departament de Ciencies Fisiologiques I, Facultat de Medicina, Barcelona (Spain); Gallego, Judith [Universitat Politecnica de Catalunya, Institut de Tecniques Energetiques, Barcelona (Spain); Institut de Bioenginyeria de Catalunya, Barcelona (Spain); Cot, Albert [Universitat de Barcelona - IDIBAPS, Unitat de Biofisica i Bioenginyeria, Departament de Ciencies Fisiologiques I, Facultat de Medicina, Barcelona (Spain); Universitat Politecnica de Catalunya, Seccio d' Enginyeria Nuclear, Departament de Fisica i Enginyeria Nuclear, Barcelona (Spain); Falcon, Carles; Ros, Domenec [Universitat de Barcelona - IDIBAPS, Unitat de Biofisica i Bioenginyeria, Departament de Ciencies Fisiologiques I, Facultat de Medicina, Barcelona (Spain); CIBER en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona (Spain); Bullich, Santiago [Hospital del Mar, Center for Imaging in Psychiatry, CRC-MAR, Barcelona (Spain); Pareto, Deborah [CIBER en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona (Spain); PRBB, Institut d' Alta Tecnologia, Barcelona (Spain); Sempau, Josep [Universitat Politecnica de Catalunya, Institut de Tecniques Energetiques, Barcelona (Spain); CIBER en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona (Spain); Lomena, Francisco [IDIBAPS, Servei de Medicina Nuclear, Hospital Clinic, Barcelona (Spain); Calvino, Francisco [Universitat Politecnica de Catalunya, Institut de Tecniques Energetiques, Barcelona (Spain); Universitat Politecnica de Catalunya, Seccio d' Enginyeria Nuclear, Departament de Fisica i Enginyeria Nuclear, Barcelona (Spain); Pavia, Javier [CIBER en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Barcelona (Spain); IDIBAPS, Servei de Medicina Nuclear, Hospital Clinic, Barcelona (Spain)

    2008-07-15

    {sup 123}I-labelled radioligands are commonly used for single-photon emission computed tomography (SPECT) imaging of the dopaminergic system to study the dopamine transporter binding. The aim of this work was to compare the quantitative capabilities of two different SPECT systems through Monte Carlo (MC) simulation. The SimSET MC code was employed to generate simulated projections of a numerical phantom for two gamma cameras equipped with a parallel and a fan-beam collimator, respectively. A fully 3D iterative reconstruction algorithm was used to compensate for attenuation, the spatially variant point spread function (PSF) and scatter. A post-reconstruction partial volume effect (PVE) compensation was also developed. For both systems, the correction for all degradations and PVE compensation resulted in recovery factors of the theoretical specific uptake ratio (SUR) close to 100%. For a SUR value of 4, the recovered SUR for the parallel imaging system was 33% for a reconstruction without corrections (OSEM), 45% for a reconstruction with attenuation correction (OSEM-A), 56% for a 3D reconstruction with attenuation and PSF corrections (OSEM-AP), 68% for OSEM-AP with scatter correction (OSEM-APS) and 97% for OSEM-APS plus PVE compensation (OSEM-APSV). For the fan-beam imaging system, the recovered SUR was 41% without corrections, 55% for OSEM-A, 65% for OSEM-AP, 75% for OSEM-APS and 102% for OSEM-APSV. Our findings indicate that the correction for degradations increases the quantification accuracy, with PVE compensation playing a major role in the SUR quantification. The proposed methodology allows us to reach similar SUR values for different SPECT systems, thereby allowing a reliable standardisation in mu