WorldWideScience

Sample records for specifically detected dc-sign

  1. Mannosyl Glycodendritic Structure Inhibits DC-SIGN-Mediated Ebola Virus Infection in cis and in trans

    OpenAIRE

    Lasala, Fátima; Arce, Eva; Otero, Joaquín R.; Rojo, Javier; Delgado, Rafael

    2003-01-01

    We have designed a glycodendritic structure, BH30sucMan, that blocks the interaction between dendritic cell-specific intercellular adhesion molecule 3-grabbing nonintegrin (DC-SIGN) and Ebola virus (EBOV) envelope. BH30sucMan inhibits DC-SIGN-mediated EBOV infection at nanomolar concentrations. BH30sucMan may counteract important steps of the infective process of EBOV and, potentially, of microorganisms shown to exploit DC-SIGN for cell entry and infection.

  2. Mannosyl Glycodendritic Structure Inhibits DC-SIGN-Mediated Ebola Virus Infection in cis and in trans

    Science.gov (United States)

    Lasala, Fátima; Arce, Eva; Otero, Joaquín R.; Rojo, Javier; Delgado, Rafael

    2003-01-01

    We have designed a glycodendritic structure, BH30sucMan, that blocks the interaction between dendritic cell-specific intercellular adhesion molecule 3-grabbing nonintegrin (DC-SIGN) and Ebola virus (EBOV) envelope. BH30sucMan inhibits DC-SIGN-mediated EBOV infection at nanomolar concentrations. BH30sucMan may counteract important steps of the infective process of EBOV and, potentially, of microorganisms shown to exploit DC-SIGN for cell entry and infection. PMID:14638512

  3. Distribution of dendritic cells expressing dendritic cell-specific ICAM-3-grabbing non-integrin (DC-SIGN, CD209): Morphological analysis using a novel Photoshop-aided multiple immunohistochemistry technique.

    Science.gov (United States)

    Masuda, Akihiro; Nishikawa, Toshio

    2014-08-01

    The distribution of dendritic cells (DCs) expressing DC-specific ICAM-3-grabbing non-integrin (DC-SIGN, CD209) and the morphological interaction of DC-SIGN⁺ DCs with other cells, especially B cells, in tonsillar and other lymphoid tissues were investigated by multiple immunohistochemistry (IHC) using the graphics editing program Photoshop, which enabled staining with 4 or more antibodies in formalin-fixed paraffin sections. Images obtained by repetition of conventional IHC using diaminobenzidine color development in a tissue section were processed on Photoshop for multiple staining. DC-SIGN⁺ DCs were present in the area around the lymphoid follicles and formed a DC-SIGN⁺ DC-rich area, and these cells contacted not only T cells, fascin⁺ DCs, and blood vessels but also several subsets of B cells simultaneously, including naïve and memory B cells. DC-SIGN⁺ DCs may play an important role in the regulation of the immune response mediated by not only T cells but also B cells. The multiple IHC method introduced in the present study is a simple and useful method for analyzing details of complex structures. Because this method can be applied to routinely processed paraffin sections with conventional IHC with diaminobenzidine, it can be applied to a wide variety of archival specimens.

  4. Rapid, directed transport of DC-SIGN clusters in the plasma membrane.

    Science.gov (United States)

    Liu, Ping; Weinreb, Violetta; Ridilla, Marc; Betts, Laurie; Patel, Pratik; de Silva, Aravinda M; Thompson, Nancy L; Jacobson, Ken

    2017-11-01

    C-type lectins, including dendritic cell-specific intercellular adhesion molecule-3-grabbing nonintegrin (DC-SIGN), are all-purpose pathogen receptors that exist in nanoclusters in plasma membranes of dendritic cells. A small fraction of these clusters, obvious from the videos, can undergo rapid, directed transport in the plane of the plasma membrane at average speeds of more than 1 μm/s in both dendritic cells and MX DC-SIGN murine fibroblasts ectopically expressing DC-SIGN. Surprisingly, instantaneous speeds can be considerably greater. In MX DC-SIGN cells, many cluster trajectories are colinear with microtubules that reside close to the ventral membrane, and the microtubule-depolymerizing drug, nocodazole, markedly reduced the areal density of directed movement trajectories, suggesting a microtubule motor-driven transport mechanism; by contrast, latrunculin A, which affects the actin network, did not depress this movement. Rapid, retrograde movement of DC-SIGN may be an efficient mechanism for bringing bound pathogen on the leading edge and projections of dendritic cells to the perinuclear region for internalization and processing. Dengue virus bound to DC-SIGN on dendritic projections was rapidly transported toward the cell center. The existence of this movement within the plasma membrane points to an unexpected lateral transport mechanism in mammalian cells and challenges our current concepts of cortex-membrane interactions.

  5. Lewis X component in human milk binds DC-SIGN and inhibits HIV-1 transfer to CD4(+) T lymphocytes

    NARCIS (Netherlands)

    Naarding, Marloes A.; Ludwig, Irene S.; Groot, Fedde; Berkhout, Ben; Geijtenbeek, Teunis B. H.; Pollakis, Georgios; Paxton, William A.

    2005-01-01

    DC-specific ICAM3-grabbing non-integrin (DC-SIGN), which is expressed on DCs, can interact with a variety of pathogens such as HIV-1, hepatitis C, Ebola, cytomegalovirus, Dengue virus, Mycobacterium, Leisbmania, and Candida albicans. We demonstrate that human milk can inhibit the DC-SIGN-mediated

  6. Rhesus macaque and chimpanzee DC-SIGN act as HIV/SIV gp120 trans-receptors, similar to human DC-SIGN

    NARCIS (Netherlands)

    Geijtenbeek, T. B.; Koopman, G.; van Duijnhoven, G. C.; van Vliet, S. J.; van Schijndel, A. C.; Engering, A.; Heeney, J. L.; van Kooyk, Y.

    2001-01-01

    Dendritic cells (DC) have been implicated in the pathogenesis of both human and simian immunodeficiency viruses (HIV and SIV, respectively). The DC-specific HIV-1 trans-receptor DC-SIGN is thought to be essential for viral dissemination by DC. Abundant expression in lymphoid tissues also implies a

  7. Human milk blocks DC-SIGN - pathogen interaction via MUC1

    Directory of Open Access Journals (Sweden)

    Nathalie eKoning

    2015-03-01

    Full Text Available Beneficial effects of breastfeeding are well-recognized and include both immediate neonatal protection against pathogens, as well as long term protection against allergies and autoimmune diseases. Although several proteins have been identified to have anti-viral or anti-bacterial effects like secretory IgA or lactoferrin, the mechanisms of immune modulation are not fully understood. Recent studies identified important beneficial effects of glycans in human milk, such as those expressed in oligosaccharides or on glycoproteins. Glycans are recognized by the carbohydrate receptors C-type lectins on DC and specific tissue macrophages, which exert important functions in immune modulation and immune homeostasis. A well-characterized C-type lectin is DC-SIGN, which binds terminal fucose. The present study shows that in human milk, MUC1 is the major milk glycoprotein that binds to the lectin domain of DC-SIGN and prevents pathogen interaction through the presence of Lewis x-type oligosaccharides. Surprisingly, this was specific for human milk, as formula, bovine or camel milk did not show any presence of proteins that interacted with DC-SIGN. The expression of DC-SIGN is found in young infants along the entire gastro-intestinal tract. Our data thus suggest the importance of human milk glycoproteins for blocking pathogen interaction to DC in young children. Moreover, a potential benefit of human milk later in life in shaping the infants immune system through DC-SIGN cannot be ruled out.

  8. Branched oligosaccharide structures on HBV prevent interaction with both DC-SIGN and L-SIGN

    NARCIS (Netherlands)

    Op den Brouw, M. L.; de Jong, M. A. W. P.; Ludwig, I. S.; van der Molen, R. G.; Janssen, H. L. A.; Geijtenbeek, T. B. H.; Woltman, A. M.

    2008-01-01

    Hepatitis B virus (HBV) is a DNA virus that infects the liver as primary target. Currently, a high affinity receptor for HBV is still unknown. The dendritic cell specific C-type lectin DC-SIGN is involved in pathogen recognition through mannose and fucose containing carbohydrates leading to the

  9. Polymeric mannosides prevent DC-SIGN-mediated cell-infection by cytomegalovirus.

    Science.gov (United States)

    Brument, S; Cheneau, C; Brissonnet, Y; Deniaud, D; Halary, F; Gouin, S G

    2017-09-20

    Human cytomegalovirus (HCMV) is a beta-herpesvirus with a high prevalence in the population. HCMV is asymptomatic for immunocompetent adults but is a leading cause of morbidity for new born and immunocompromised patients. It was recently shown that the envelope glycoprotein B (gB) of HCMV interacts with the Dendritic Cell-Specific ICAM-3 Grabbing Non integrin (DC-SIGN) to infect the host. In this work we developed a set of DC-SIGN blockers based on mono-, di-, tetra and polyvalent mannosides. The multivalent mannosides were designed to interact with the carbohydrate recognition domains of DC-SIGN in a chelate or bind and recapture process, and represent the first chemical antiadhesives of HCMV reported so far. Polymeric dextrans coated with triazolylheptylmannoside (THM) ligands were highly potent, blocking the gB and DC-SIGN interaction at nanomolar concentrations. The compounds were further assessed for their ability to prevent the DC-SIGN mediated HCMV infection of dendritic cells. A dextran polymer coated with an average of 902 THM ligands showed an outstanding effect in blocking the HCMV trans-infection with IC 50 values down to the picomolar range (nanomolar when expressed in THM concentration). Each THM moiety on the polymer surpassed the antiadhesive effect of the methylmannoside reference by more than four orders of magnitude. The compound proved non-cytotoxic at the high concentration of 2 mM and therefore represents an interesting antiadhesive candidate against HCMV and potentially against other virus hijacking dendritic cells to infect the host.

  10. AFM force spectroscopy reveals how subtle structural differences affect the interaction strength between Candida albicans and DC-SIGN.

    Science.gov (United States)

    te Riet, Joost; Reinieren-Beeren, Inge; Figdor, Carl G; Cambi, Alessandra

    2015-11-01

    The fungus Candida albicans is the most common cause of mycotic infections in immunocompromised hosts. Little is known about the initial interactions between Candida and immune cell receptors, such as the C-type lectin dendritic cell-specific intracellular cell adhesion molecule-3 (ICAM-3)-grabbing non-integrin (DC-SIGN), because a detailed characterization at the structural level is lacking. DC-SIGN recognizes specific Candida-associated molecular patterns, that is, mannan structures present in the cell wall of Candida. The molecular recognition mechanism is however poorly understood. We postulated that small differences in mannan-branching may result in considerable differences in the binding affinity. Here, we exploit atomic force microscope-based dynamic force spectroscopy with single Candida cells to gain better insight in the carbohydrate recognition capacity of DC-SIGN. We demonstrate that slight differences in the N-mannan structure of Candida, that is, the absence or presence of a phosphomannan side chain, results in differences in the recognition by DC-SIGN as follows: (i) it contributes to the compliance of the outer cell wall of Candida, and (ii) its presence results in a higher binding energy of 1.6 kB T. The single-bond affinity of tetrameric DC-SIGN for wild-type C. albicans is ~10.7 kB T and a dissociation constant kD of 23 μM, which is relatively strong compared with other carbohydrate-protein interactions described in the literature. In conclusion, this study shows that DC-SIGN specifically recognizes mannan patterns on C. albicans with high affinity. Knowledge on the binding pocket of DC-SIGN and its pathogenic ligands will lead to a better understanding of how fungal-associated carbohydrate structures are recognized by receptors of the immune system and can ultimately contribute to the development of new anti-fungal drugs. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Neisseria meningitidis expressing lgtB lipopolysaccharide targets DC-SIGN and modulates dendritic cell function.

    Science.gov (United States)

    Steeghs, Liana; van Vliet, Sandra J; Uronen-Hansson, Heli; van Mourik, Andries; Engering, Anneke; Sanchez-Hernandez, Martha; Klein, Nigel; Callard, Robin; van Putten, Jos P M; van der Ley, Peter; van Kooyk, Yvette; van de Winkel, Jan G J

    2006-02-01

    Neisseria meningitidis lipopolysaccharide (LPS) has been identified as a major determinant of dendritic cell (DC) function. Here we report that one of a series of meningococcal mutants with defined truncations in the lacto-N-neotetraose outer core of the LPS exhibited unique strong adhesion and internalization properties towards DC. These properties were mediated by interaction of the GlcNAc(beta1-3)-Gal(beta1-4)-Glc-R oligosaccharide outer core of lgtB LPS with the dendritic-cell-specific ICAM-3 grabbing non-integrin (DC-SIGN) lectin receptor. Activation of DC-SIGN with this novel oligosaccharide ligand skewed T-cell responses driven by DC towards T helper type 1 activity. Thus, the use of lgtB LPS may provide a powerful instrument to selectively induce the desired arm of the immune response and potentially increase vaccine efficacy.

  12. Sequencing of DC-SIGN promoter indicates an association between promoter variation and risk of nasopharyngeal carcinoma in cantonese

    Directory of Open Access Journals (Sweden)

    Liu Wen-Sheng

    2010-11-01

    Full Text Available Abstract Background The dendritic cell-specific intercellular adhesion molecule 3 grabbing non-integrin (DC-SIGN is an important pathogen recognition receptor of the innate immune system. DC-SIGN promoter variants play important role in the susceptibility to various infectious diseases. Nasopharyngeal carcinoma (NPC is a malignancy that is common in southern China and whether DC-SIGN promoter variants have effects on susceptibility to NPC is still unknown. The aim of this study is to ascertain the potential involvement of DC-SIGN promoter single nucleotide polymorphisms (SNPs in NPC susceptibility. Methods We conducted a case control study based on Cantonese population including 444 NPC patients and 464 controls matched on age and sex. The 1041 bp of DC-SIGN promoter region was directly sequenced for all samples. Sequence alignment and SNP search were inspected using DNAStar analysis programs and haplotype frequencies were estimated in Haploview V 4.0. The associations between the SNPs and the risk of NPC were analyzed using chi-square test and non-conditional logistic regression analysis with SPSS 13.0 software. Results A total of six variants were observed in the DC-SIGN promoter region and DC-SIGN -139 GG and -939 AA were significantly associated with NPC risk with adjusted Odds Ratios (ORs of 2.10 (95% confidence interval [CI] = 1.23-3.59; P = 0.006 and 2.52 (1.29-4.93; P = 0.007 respectively and subjects carrying the risk allele DC-SIGN -871 G had 1.47-fold (95% CI = 1.14-1.90 increased risks of developing NPC (P = 0.003. Haplotype analysis revealed that h1 'AAAG' was significantly associated with protection against NPC (OR = 0.69; P = 0.0002 and the association was still significant when using 1000 permutation test runs (P = 0.001. Conclusions Our study indicated that DC-SIGN promoter variants appear to be involved in the susceptibility to NPC and the detailed mechanism of this effect need further studies.

  13. Interaction and inhibition of dengue envelope glycoprotein with mammalian receptor DC-sign, an in-silico approach.

    Directory of Open Access Journals (Sweden)

    Masaud Shah

    Full Text Available Membrane fusion is the central molecular event during the entry of enveloped viruses into cells. The critical agents of this process are viral surface proteins, primed to facilitate cell bilayer fusion. The important role of Dendritic-cell-specific ICAM3-grabbing non-integrin (DC-SIGN in Dengue virus transmission makes it an attractive target to interfere with Dengue virus Propagation. Receptor mediated endocytosis allows the entry of virions due to the presence of endosomal membranes and low pH-induced fusion of the virus. DC-SIGN is the best characterized molecule among the candidate protein receptors and is able to mediate infection with the four serotypes of dengue virus (DENV. Unrestrained pair wise docking was used for the interaction of dengue envelope protein with DC-SIGN and monoclonal antibody 2G12. Pre-processed the PDB coordinates of dengue envelope glycoprotein and other candidate proteins were prepared and energy minimized through AMBER99 force field distributed in MOE software. Protein-protein interaction server, ZDOCK was used to find molecular interaction among the candidate proteins. Based on these interactions it was found that antibody successfully blocks the glycosylation site ASN 67 and other conserved residues present at DC-SIGN-Den-E complex interface. In order to know for certain, the exact location of the antibody in the envelope protein, co-crystallize of the envelope protein with these compounds is needed so that their exact docking locations can be identified with respect to our results.

  14. Identification and molecular profiling of DC-SIGN-like from big belly seahorse (Hippocampus abdominalis) inferring its potential relevancy in host immunity.

    Science.gov (United States)

    Jo, Eunyoung; Elvitigala, Don Anushka Sandaruwan; Wan, Qiang; Oh, Minyoung; Oh, Chulhong; Lee, Jehee

    2017-12-01

    Dendritic-cell-specific ICAM-3-grabbing non-integrin (DC-SIGN) is a C-type lectin that functions as a pattern recognition receptor by recognizing pathogen-associated molecular patterns (PAMPs). It is also involved in various events of the dendritic cell (DC) life cycle, such as DC migration, antigen capture and presentation, and T cell priming. In this study, a DC-SIGN-like gene from the big belly seahorse Hippocampus abdominalis (designated as ShDCS-like) was identified and molecularly characterized. The putative, complete ORF was found to be 1368 bp in length, encoding a protein of 462 amino acids with a molecular mass of 52.6 kDa and a theoretical isoelectric point of 8.26. The deduced amino acid sequence contains a single carbohydrate recognition domain (CRD), in which six conserved cysteine residues and two Ca 2+ -binding site motifs (QPN, WND) were identified. Based on pairwise sequence analysis, ShDCS-like exhibits the highest amino acid identity (94.6%) and similarity (97.4%) with DC-SIGN-like counterpart from tiger tail seahorse Hippocampus comes. Quantitative real-time PCR revealed that ShDCS-like mRNA is transcribed universally in all tissues examined, but with abundance in kidney and gill tissues. The basal mRNA expression of ShDCS-like was modulated in blood cell, kidney, gill and liver tissues in response to the stimulation of healthy fish with lipopolysaccharides (LPS), Edwardsiella tarda, or Streptococcus iniae. Moreover, recombinant ShDCS-like-CRD domain exhibited detectable agglutination activity against different bacteria. Collectively, these results suggest that ShDCS-like may potentially involve in immune function in big belly seahorses. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. N-Glycans on the Rift Valley Fever Virus Envelope Glycoproteins Gn and Gc Redundantly Support Viral Infection via DC-SIGN

    Science.gov (United States)

    Phoenix, Inaia; Nishiyama, Shoko; Lokugamage, Nandadeva; Hill, Terence E.; Huante, Matthew B.; Slack, Olga A.L.; Carpio, Victor H.; Freiberg, Alexander N.; Ikegami, Tetsuro

    2016-01-01

    Rift Valley fever is a mosquito-transmitted, zoonotic disease that infects humans and ruminants. Dendritic cell specific intercellular adhesion molecule 3 (ICAM-3) grabbing non-integrin (DC-SIGN) acts as a receptor for members of the phlebovirus genus. The Rift Valley fever virus (RVFV) glycoproteins (Gn/Gc) encode five putative N-glycan sequons (asparagine (N)–any amino acid (X)–serine (S)/threonine (T)) at positions: N438 (Gn), and N794, N829, N1035, and N1077 (Gc). The N-glycosylation profile and significance in viral infection via DC-SIGN have not been elucidated. Gc N-glycosylation was first evaluated by using Gc asparagine (N) to glutamine (Q) mutants. Subsequently, we generated a series of recombinant RVFV MP-12 strain mutants, which encode N-to-Q mutations, and the infectivity of each mutant in Jurkat cells stably expressing DC-SIGN was evaluated. Results showed that Gc N794, N1035, and N1077 were N-glycosylated but N829 was not. Gc N1077 was heterogeneously N-glycosylated. RVFV Gc made two distinct N-glycoforms: “Gc-large” and “Gc-small”, and N1077 was responsible for “Gc-large” band. RVFV showed increased infection of cells expressing DC-SIGN compared to cells lacking DC-SIGN. Infection via DC-SIGN was increased in the presence of either Gn N438 or Gc N1077. Our study showed that N-glycans on the Gc and Gn surface glycoproteins redundantly support RVFV infection via DC-SIGN. PMID:27223297

  16. Role of the carbohydrate-binding sites of griffithsin in the prevention of DC-SIGN-mediated capture and transmission of HIV-1.

    Directory of Open Access Journals (Sweden)

    Bart Hoorelbeke

    Full Text Available BACKGROUND: The glycan-targeting C-type DC-SIGN lectin receptor is implicated in the transmission of the human immunodeficiency virus (HIV by binding the virus and transferring the captured HIV-1 to CD4(+ T lymphocytes. Carbohydrate binding agents (CBAs have been reported to block HIV-1 infection. We have now investigated the potent mannose-specific anti-HIV CBA griffithsin (GRFT on its ability to inhibit the capture of HIV-1 to DC-SIGN, its DC-SIGN-directed transmission to CD4(+ T-lymphocytes and the role of the three carbohydrate-binding sites (CBS of GRFT in these processes. FINDINGS: GRFT inhibited HIV-1(IIIB infection of CEM and HIV-1(NL4.3 infection of C8166 CD4(+ T-lymphocytes at an EC50 of 0.059 and 0.444 nM, respectively. The single mutant CBS variants of GRFT (in which a key Asp in one of the CBS was mutated to Ala were about ∼20 to 60-fold less potent to prevent HIV-1 infection and ∼20 to 90-fold less potent to inhibit syncytia formation in co-cultures of persistently HIV-1 infected HuT-78 and uninfected C8166 CD4(+ T-lymphocytes. GRFT prevents DC-SIGN-mediated virus capture and HIV-1 transmission to CD4(+ T-lymphocytes at an EC50 of 1.5 nM and 0.012 nM, respectively. Surface plasmon resonance (SPR studies revealed that wild-type GRFT efficiently blocked the binding between DC-SIGN and immobilized gp120, whereas the point mutant CBS variants of GRFT were ∼10- to 15-fold less efficient. SPR-analysis also demonstrated that wild-type GRFT and its single mutant CBS variants have the capacity to expel bound gp120 from the gp120-DC-SIGN complex in a dose dependent manner, a property that was not observed for HHA, another mannose-specific potent anti-HIV-1 CBA. CONCLUSION: GRFT is inhibitory against HIV gp120 binding to DC-SIGN, efficiently prevents DC-SIGN-mediated transfer of HIV-1 to CD4(+ T-lymphocytes and is able to expel gp120 from the gp120-DC-SIGN complex. Functionally intact CBS of GRFT are important for the optimal action of

  17. The lectins griffithsin, cyanovirin-N and scytovirin inhibit HIV-1 binding to the DC-SIGN receptor and transfer to CD4+ cells

    CSIR Research Space (South Africa)

    Alexandre, Kabamba B

    2012-02-01

    Full Text Available It is generally believed that during the sexual transmission of HIV-1, the glycan-specific DC-SIGN receptor binds the virus and mediates its transfer to CD4(+) cells. The lectins griffithsin (GRFT), cyanovirin-N (CV-N) and scytovirin (SVN) inhibit...

  18. Bile salt-stimulated lipase from human milk binds DC-SIGN and inhibits human immunodeficiency virus type 1 transfer to CD4+ T cells

    NARCIS (Netherlands)

    Naarding, Marloes A.; Dirac, Annette M.; Ludwig, Irene S.; Speijer, Dave; Lindquist, Susanne; Vestman, Eva-Lotta; Stax, Martijn J.; Geijtenbeek, Teunis B. H.; Pollakis, Georgios; Hernell, Olle; Paxton, William A.

    2006-01-01

    A wide range of pathogens, including human immunodeficiency virus type 1 (HIV-1), hepatitis C virus, Ebola virus, cytomegalovirus, dengue virus, Mycobacterium, Leishmania, and Helicobacter pylori, can interact with dendritic cell (DC)-specific ICAM3-grabbing nonintegrin (DC-SIGN), expressed on DCs

  19. Simian virus 40 inhibits differentiation and maturation of rhesus macaque DC-SIGN+-dendritic cells

    Directory of Open Access Journals (Sweden)

    Changyong G

    2010-09-01

    Full Text Available Abstract Dendritic cells (DC are the initiators and modulators of the immune responses. Some species of pathogenic microorganisms have developed immune evasion strategies by controlling antigen presentation function of DC. Simian virus 40 (SV40 is a DNA tumor virus of rhesus monkey origin. It can induce cell transformation and tumorigenesis in many vertebrate species, but often causes no visible effects and persists as a latent infection in rhesus monkeys under natural conditions. To investigate the interaction between SV40 and rhesus monkey DC, rhesus monkey peripheral blood monocyte-derived DC were induced using recombinant human Interleukin-4 (rhIL-4 and infective SV40, the phenotype and function of DC-specific intracellular adhesion molecule-3 grabbing nonintegrin (DC-SIGN+ DC were analyzed by flow cytometry (FCM and mixed lymphocyte reaction (MLR. Results showed that SV40 can down-regulate the expression of CD83 and CD86 on DC and impair DC-induced activation of T cell proliferation. These findings suggest that SV40 might also cause immune suppression by influencing differentiation and maturation of DC.

  20. S-layer proteins from Lactobacillus sp. inhibit bacterial infection by blockage of DC-SIGN cell receptor.

    Science.gov (United States)

    Prado Acosta, Mariano; Ruzal, Sandra M; Cordo, Sandra M

    2016-11-01

    Many species of Lactobacillus sp. possess Surface(s) layer proteins in their envelope. Among other important characteristics S-layer from Lactobacillus acidophilus binds to the cellular receptor DC-SIGN (Dendritic Cell-Specific Intercellular adhesion molecule-3-Grabbing Non-integrin; CD209), which is involved in adhesion and infection of several families of bacteria. In this report we investigate the activity of new S-layer proteins from the Lactobacillus family (Lactobacillus acidophilus, Lactobacillus brevis, Lactobacillus helveticus and Lactobacillus kefiri) over the infection of representative microorganisms important to human health. After the treatment of DC-SIGN expressing cells with these proteins, we were able to diminish bacterial infection by up to 79% in both gram negative and mycobacterial models. We discovered that pre-treatment of the bacteria with S-layers from Lactobacillus acidophilus and Lactobacillus brevis reduced bacteria viability but also prevent infection by the pathogenic bacteria. We also proved the importance of the glycosylation of the S-layer from Lactobacillus kefiri in the binding to the receptor and thus inhibition of infection. This novel characteristic of the S-layers proteins may contribute to the already reported pathogen exclusion activity for these Lactobacillus probiotic strains; and might be also considered as a novel enzymatic antimicrobial agents to inhibit bacterial infection and entry to host cells. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Identification of Multiple Druggable Secondary Sites by Fragment Screening against DC-SIGN.

    Science.gov (United States)

    Aretz, Jonas; Baukmann, Hannes; Shanina, Elena; Hanske, Jonas; Wawrzinek, Robert; Zapol'skii, Viktor A; Seeberger, Peter H; Kaufmann, Dieter E; Rademacher, Christoph

    2017-06-12

    DC-SIGN is a cell-surface receptor for several pathogenic threats, such as HIV, Ebola virus, or Mycobacterium tuberculosis. Multiple attempts to develop inhibitors of the underlying carbohydrate-protein interactions have been undertaken in the past fifteen years. Still, drug-like DC-SIGN ligands are sparse, which is most likely due to its hydrophilic, solvent-exposed carbohydrate-binding site. Herein, we report on a parallel fragment screening against DC-SIGN applying SPR and a reporter displacement assay, which complements previous screenings using 19 F NMR spectroscopy and chemical fragment microarrays. Hit validation by SPR and 1 H- 15 N HSQC NMR spectroscopy revealed that although no fragment bound in the primary carbohydrate site, five secondary sites are available to harbor drug-like molecules. Building on key interactions of the reported fragment hits, these pockets will be targeted in future approaches to accelerate the development of DC-SIGN inhibitors. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Nanoscale organization of the pathogen receptor DC-SIGN mapped by single-molecule high-resolution fluorescence microscopy.

    NARCIS (Netherlands)

    Bakker, B.I. de; Lange, F. de; Cambi, A.; Korterik, J.P.; Dijk, E.M. van; Hulst, N.F. van; Figdor, C.G.; Garcia-Parajo, M.F.

    2007-01-01

    DC-SIGN, a C-type lectin exclusively expressed on dendritic cells (DCs), plays an important role in pathogen recognition by binding with high affinity to a large variety of microorganisms. Recent experimental evidence points to a direct relation between the function of DC-SIGN as a viral receptor

  3. Nanoscale organization of the pathogen receptor DC-SIGN mapped by single-molecule high-resolution flourescence microscopy

    NARCIS (Netherlands)

    de Bakker, B.I.; de Lange, Frank; Cambi, Alessandra; Cambi, A.; Korterik, Jeroen P.; van Dijk, E.M.H.P.; van Hulst, N.F.; Figdor, Carl; Garcia Parajo, M.F.

    2007-01-01

    DC-SIGN, a C-type lectin exclusively expressed on dendritic cells (DCs), plays an important role in pathogen recognition by binding with high affinity to a large variety of microorganisms. Recent experimental evidence points to a direct relation between the function of DC-SIGN as a viral receptor

  4. DC-SIGN mediates avian H5N1 influenza virus infection in cis and in trans

    International Nuclear Information System (INIS)

    Wang, S.-F.; Huang, Jason C.; Lee, Y.-M.; Liu, S.-J.; Chan, Yu-Jiun; Chau, Y.-P.; Chong, P.; Chen, Y.-M.A.

    2008-01-01

    DC-SIGN, a C-type lectin receptor expressed in dendritic cells (DCs), has been identified as a receptor for human immunodeficiency virus type 1, hepatitis C virus, Ebola virus, cytomegalovirus, dengue virus, and the SARS coronavirus. We used H5N1 pseudotyped and reverse-genetics (RG) virus particles to study their ability to bind with DC-SIGN. Electronic microscopy and functional assay results indicate that pseudotyped viruses containing both HA and NA proteins express hemagglutination and are capable of infecting cells expressing α-2,3-linked sialic acid receptors. Results from a capture assay show that DC-SIGN-expressing cells (including B-THP-1/DC-SIGN and T-THP-1/DC-SIGN) and peripheral blood dendritic cells are capable of transferring H5N1 pseudotyped and RG virus particles to target cells; this action can be blocked by anti-DC-SIGN monoclonal antibodies. In summary, (a) DC-SIGN acts as a capture or attachment molecule for avian H5N1 virus, and (b) DC-SIGN mediates infections in cis and in trans

  5. Colorectal mucus binds DC-SIGN and inhibits HIV-1 trans-infection of CD4+ T-lymphocytes.

    Directory of Open Access Journals (Sweden)

    Martijn J Stax

    Full Text Available Bodily secretions, including breast milk and semen, contain factors that modulate HIV-1 infection. Since anal intercourse caries one of the highest risks for HIV-1 transmission, our aim was to determine whether colorectal mucus (CM also contains factors interfering with HIV-1 infection and replication. CM from a number of individuals was collected and tested for the capacity to bind DC-SIGN and inhibit HIV-1 cis- or trans-infection of CD4+ T-lymphocytes. To this end, a DC-SIGN binding ELISA, a gp140 trimer competition ELISA and HIV-1 capture/ transfer assays were utilized. Subsequently we aimed to identify the DC-SIGN binding component through biochemical characterization and mass spectrometry analysis. CM was shown to bind DC-SIGN and competes with HIV-1 gp140 trimer for binding. Pre-incubation of Raji-DC-SIGN cells or immature dendritic cells (iDCs with CM potently inhibits DC-SIGN mediated trans-infection of CD4+ T-lymphocytes with CCR5 and CXCR4 using HIV-1 strains, while no effect on direct infection is observed. Preliminary biochemical characterization demonstrates that the component seems to be large (>100kDa, heat and proteinase K resistant, binds in a α1-3 mannose independent manner and is highly variant between individuals. Immunoprecipitation using DC-SIGN-Fc coated agarose beads followed by mass spectrometry indicated lactoferrin (fragments and its receptor (intelectin-1 as candidates. Using ELISA we showed that lactoferrin levels within CM correlate with DC-SIGN binding capacity. In conclusion, CM can bind the C-type lectin DC-SIGN and block HIV-1 trans-infection of both CCR5 and CXCR4 using HIV-1 strains. Furthermore, our data indicate that lactoferrin is a DC-SIGN binding component of CM. These results indicate that CM has the potential to interfere with pathogen transmission and modulate immune responses at the colorectal mucosa.

  6. Colorectal mucus binds DC-SIGN and inhibits HIV-1 trans-infection of CD4+ T-lymphocytes.

    Science.gov (United States)

    Stax, Martijn J; Mouser, Emily E I M; van Montfort, Thijs; Sanders, Rogier W; de Vries, Henry J C; Dekker, Henk L; Herrera, Carolina; Speijer, Dave; Pollakis, Georgios; Paxton, William A

    2015-01-01

    Bodily secretions, including breast milk and semen, contain factors that modulate HIV-1 infection. Since anal intercourse caries one of the highest risks for HIV-1 transmission, our aim was to determine whether colorectal mucus (CM) also contains factors interfering with HIV-1 infection and replication. CM from a number of individuals was collected and tested for the capacity to bind DC-SIGN and inhibit HIV-1 cis- or trans-infection of CD4+ T-lymphocytes. To this end, a DC-SIGN binding ELISA, a gp140 trimer competition ELISA and HIV-1 capture/ transfer assays were utilized. Subsequently we aimed to identify the DC-SIGN binding component through biochemical characterization and mass spectrometry analysis. CM was shown to bind DC-SIGN and competes with HIV-1 gp140 trimer for binding. Pre-incubation of Raji-DC-SIGN cells or immature dendritic cells (iDCs) with CM potently inhibits DC-SIGN mediated trans-infection of CD4+ T-lymphocytes with CCR5 and CXCR4 using HIV-1 strains, while no effect on direct infection is observed. Preliminary biochemical characterization demonstrates that the component seems to be large (>100kDa), heat and proteinase K resistant, binds in a α1-3 mannose independent manner and is highly variant between individuals. Immunoprecipitation using DC-SIGN-Fc coated agarose beads followed by mass spectrometry indicated lactoferrin (fragments) and its receptor (intelectin-1) as candidates. Using ELISA we showed that lactoferrin levels within CM correlate with DC-SIGN binding capacity. In conclusion, CM can bind the C-type lectin DC-SIGN and block HIV-1 trans-infection of both CCR5 and CXCR4 using HIV-1 strains. Furthermore, our data indicate that lactoferrin is a DC-SIGN binding component of CM. These results indicate that CM has the potential to interfere with pathogen transmission and modulate immune responses at the colorectal mucosa.

  7. Expression of the dendritic cell-associated C-type lectin DC-SIGN by inflammatory matrix metalloproteinase-producing macrophages in rheumatoid arthritis synovium and interaction with intercellular adhesion molecule 3-positive T cells.

    NARCIS (Netherlands)

    Lent, P.L.E.M. van; Figdor, C.G.; Barrera Rico, P.; Ginkel, K. van; Sloetjes, A.W.; Berg, W.B. van den; Torensma, R.

    2003-01-01

    OBJECTIVE: To determine whether matrix metalloproteinase (MMP)-producing inflammatory macrophages in the synovium of rheumatoid arthritis (RA) patients express the novel dendritic cell (DC)-specific C-type lectin DC-SIGN and whether this expression is associated with the presence of naive T cells

  8. Porphyromonas gingivalis evasion of autophagy and intracellular killing by human myeloid dendritic cells involves DC-SIGN-TLR2 crosstalk.

    Science.gov (United States)

    El-Awady, Ahmed R; Miles, Brodie; Scisci, Elizabeth; Kurago, Zoya B; Palani, Chithra D; Arce, Roger M; Waller, Jennifer L; Genco, Caroline A; Slocum, Connie; Manning, Matthew; Schoenlein, Patricia V; Cutler, Christopher W

    2015-02-01

    Signaling via pattern recognition receptors (PRRs) expressed on professional antigen presenting cells, such as dendritic cells (DCs), is crucial to the fate of engulfed microbes. Among the many PRRs expressed by DCs are Toll-like receptors (TLRs) and C-type lectins such as DC-SIGN. DC-SIGN is targeted by several major human pathogens for immune-evasion, although its role in intracellular routing of pathogens to autophagosomes is poorly understood. Here we examined the role of DC-SIGN and TLRs in evasion of autophagy and survival of Porphyromonas gingivalis in human monocyte-derived DCs (MoDCs). We employed a panel of P. gingivalis isogenic fimbriae deficient strains with defined defects in Mfa-1 fimbriae, a DC-SIGN ligand, and FimA fimbriae, a TLR2 agonist. Our results show that DC-SIGN dependent uptake of Mfa1+P. gingivalis strains by MoDCs resulted in lower intracellular killing and higher intracellular content of P. gingivalis. Moreover, Mfa1+P. gingivalis was mostly contained within single membrane vesicles, where it survived intracellularly. Survival was decreased by activation of TLR2 and/or autophagy. Mfa1+P. gingivalis strain did not induce significant levels of Rab5, LC3-II, and LAMP1. In contrast, P. gingivalis uptake through a DC-SIGN independent manner was associated with early endosomal routing through Rab5, increased LC3-II and LAMP-1, as well as the formation of double membrane intracellular phagophores, a characteristic feature of autophagy. These results suggest that selective engagement of DC-SIGN by Mfa-1+P. gingivalis promotes evasion of antibacterial autophagy and lysosome fusion, resulting in intracellular persistence in myeloid DCs; however TLR2 activation can overcome autophagy evasion and pathogen persistence in DCs.

  9. Associations of DC-SIGN (CD209) promoter -336G/A polymorphism (rs4804803) with dengue infection: A systematic review and meta-analysis.

    Science.gov (United States)

    Pabalan, Noel; Chaisri, Suwit; Tabunhan, Sompong; Phumyen, Achara; Jarjanazi, Hamdi; Steiner, Theodore S

    2018-01-01

    Dengue virus entry into a host is associated with a cell surface protein, DC-SIGN (dendritic cell-specific intercellular adhesion molecule-3 grabbing non-integrin). A common CD209-336G/A (rs4804803) polymorphism in DC-SIGN may affect severity of dengue virus infection (DEN) and incidence of dengue fever (DF) or the more severe dengue hemorrhagic fever (DHF). However, the reported associations of these two outcomes and CD-209 have been inconsistent, which prompted a meta-analysis to obtain more precise estimates. A literature search yielded seven case-control studies. We calculated pooled odds ratios (OR) and 95% confidence intervals using standard genetic models. Outlier treatment examined sources of potential heterogeneity. Subgroup analysis was performed for ethnicity and age. All significant outcomes for association indicating reduced risk were pegged at P=0.007-0.05. In the homozygous and recessive models, these were observed in the overall analysis (OR 0.52-0.55), and subgroups of South/Central Americans (OR 0.30-0.32) and school-age children (OR 0.44) in the DHF analysis as well as the codominant model among Asians in DF (OR 0.59). These significant outcomes are strengthened by their non-heterogeneity (P>0.10) and robustness of the effects. Most pooled effects in DF and DEN were variable. The DC-SIGN -336G/A polymorphism significantly affects DHF and DF incidence with the effect more pronounced in certain analyzed patient subgroups. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Inefficient HIV-1 trans infection of CD4+ T cells by macrophages from HIV-1 nonprogressors is associated with altered membrane cholesterol and DC-SIGN.

    Science.gov (United States)

    DeLucia, Diana C; Rinaldo, Charles R; Rappocciolo, Giovanna

    2018-04-11

    Professional antigen presenting cells (APC: myeloid dendritic cells (DC) and macrophages (MΦ); B lymphocytes) mediate highly efficient HIV-1 infection of CD4 + T cells, termed trans infection, that could contribute to HIV-1 pathogenesis. We have previously shown that lower cholesterol content in DC and B lymphocytes is associated with a lack of HIV-1 trans infection in HIV-1 infected nonprogressors (NP). Here we assessed whether HIV-1 trans infection mediated by another major APC, MΦ, is deficient in NP due to altered cholesterol metabolism. When comparing healthy HIV-1 seronegatives (SN), rapid progressors (PR), and NP, we found that monocyte-derived MΦ from NP did not mediate HIV-1 trans infection of autologous CD4 + T cells, in contrast to efficient trans infection mediated by SN and PR MΦ. MΦ trans infection efficiency was directly associated with the number of DC-specific intercellular adhesion molecule-3-grabbing non-integrin (DC-SIGN)-expressing MΦ. Significantly fewer NP MΦ expressed DC-SIGN. Unesterified (free) cholesterol in MΦ cell membranes and lipid rafting was significantly lower in NP than PR, as well as virus internalization in early endosomes. Furthermore, simvastatin (SIMV), decreased the subpopulation of DC-SIGN + MΦ, as well as MΦ cis and trans infection. Notably, SIMV decreased cell membrane cholesterol and led to lipid raft dissociation, effectively mimicking the incompetent APC trans infection environment characteristic of NP. Our data support that DC-SIGN and membrane cholesterol are central to MΦ trans infection, and a lack of these limits HIV-1 disease progression. Targeting the ability of MΦ to drive HIV-1 dissemination in trans could enhance HIV-1 therapeutic strategies. IMPORTANCE Despite the success of combination anti-retroviral therapy, neither a vaccine nor a cure for HIV infection has been developed, demonstrating a need for novel prophylactic and therapeutic strategies. Here we show that efficiency of macrophage (M

  11. Polyvalent C-glycomimetics based on L-fucose or D-mannose as potent DC-SIGN antagonists

    Czech Academy of Sciences Publication Activity Database

    Bertolotti, B.; Sutkeviciute, I.; Ambrosini, M.; Ribeiro-Viana, R.; Rojo, J.; Fieschi, F.; Dvořáková, H.; Kašáková, M.; Parkan, K.; Hlaváčková, M.; Nováková, Kateřina; Moravcová, J.

    2017-01-01

    Roč. 15, č. 18 (2017), s. 3995-4004 ISSN 1477-0520 Institutional support: RVO:61388963 Keywords : glycomimetics * DC_SIGN * antagonist Subject RIV: CC - Organic Chemistry OBOR OECD: Organic chemistry Impact factor: 3.564, year: 2016

  12. DNA and protein co-administration induces tolerogenic dendritic cells through DC-SIGN mediated negative signals.

    Science.gov (United States)

    Li, Jinyao; Geng, Shuang; Liu, Xiuping; Liu, Hu; Jin, Huali; Liu, Chang-Gong; Wang, Bin

    2013-10-01

    We previously demonstrated that DNA and protein co-administration induced differentiation of immature dendritic cells (iDCs) into CD11c(+)CD40(low)IL-10(+) regulatory DCs (DCregs) via the caveolin-1 (Cav-1) -mediated signal pathway. Here, we demonstrate that production of IL-10 and the low expression of CD40 play a critical role in the subsequent induction of regulatory T cells (Tregs) by the DCregs. We observed that DNA and protein were co-localized with DC-SIGN in caveolae and early lysosomes in the treated DCs, as indicated by co-localization with Cav-1 and EEA-1 compartment markers. DNA and protein also co-localized with LAMP-2. Gene-array analysis of gene expression showed that more than a thousand genes were significantly changed by the DC co-treatment with DNA + protein compared with controls. Notably, the level of DC-SIGN expression was dramatically upregulated in pOVA + OVA co-treated DCs. The expression levels of Rho and Rho GNEF, the down-stream molecules of DC-SIGN mediated signal pathway, were also greatly upregulated. Further, the level of TLR9, the traditional DNA receptor, was significantly downregulated. These results suggest that DC-SIGN as the potential receptor for DNA and protein might trigger the negative pathway to contribute the induction of DCreg combining with Cav-1 mediated negative signal pathway.

  13. The neck region of the C-type lectin DC-SIGN regulates its surface spatiotemporal organization and virus-binding capacity on antigen presenting cells

    NARCIS (Netherlands)

    Manzo, C.; Torreno-Pina, J.A.; Joosten, B.; Reinieren-Beeren, I.; Gualda, E.J.; Loza-Alvarez, P.; Figdor, Carl; Garcia Parajo, M.F.; Cambi, A.

    2012-01-01

    The C-type lectin DC-SIGN expressed on dendritic cells (DCs) facilitates capture and internalization of a plethora of different pathogens. Although it is known that DC-SIGN organizes in nanoclusters at the surface of DCs, the molecular mechanisms responsible for this well defined nanopatterning and

  14. The Neck Region of the C-type Lectin DC-SIGN Regulates Its Surface Spatiotemporal Organization and Virus-binding Capacity on Antigen-presenting Cells

    NARCIS (Netherlands)

    Manzo, C.; Torreno-Pina, J.A.; Joosten, B.; Reinieren-Beeren, I.; Gualda, E.J.; Loza-Alvarez, P.; Figdor, C.G.; Garcia-Parajo, M.F.; Cambi, A.

    2012-01-01

    The C-type lectin DC-SIGN expressed on dendritic cells (DCs) facilitates capture and internalization of a plethora of different pathogens. Although it is known that DC-SIGN organizes in nanoclusters at the surface of DCs, the molecular mechanisms responsible for this well defined nanopatterning and

  15. DC-SIGN neck domain is a pH-sensor controlling oligomerization: SAXS and hydrodynamic studies of extracellular domain.

    Science.gov (United States)

    Tabarani, Georges; Thépaut, Michel; Stroebel, David; Ebel, Christine; Vivès, Corinne; Vachette, Patrice; Durand, Dominique; Fieschi, Franck

    2009-08-07

    DC-SIGN is a C-type lectin receptor of dendritic cells and is involved in the early stages of numerous infectious diseases. DC-SIGN is organized into a tetramer enabling multivalent interaction with pathogens. Once formed, the DC-SIGN-pathogen complex can be internalized into compartments of increasing acidity. We have studied the pH dependence of the oligomerization state and conformation of the entire extracellular domain and neck region. We present evidence for equilibrium between the monomeric and tetrameric states of the extracellular domain, which exhibits a marked dependence with respect to both pH and ionic strength. Using solution x-ray scattering we have obtained a molecular envelope of the extracellular domain in which a model has been built. Our results highlight the central role of the neck domain in the pH-sensitive control of the oligomerization state, in the extended conformation of the protein, and in carbohydrate recognition domain organization and presentation. This work opens new insight into the molecular mechanism of ligand release and points to new avenues to block the first step of this important infection pathway.

  16. DC-SIGN (CD209), pentraxin 3 and vitamin D receptor gene variants associate with pulmonary tuberculosis risk in West Africans

    DEFF Research Database (Denmark)

    Olesen, R; Wejse, C; Velez, D R

    2007-01-01

    We investigated the role of DC-SIGN (CD209), long pentraxin 3 (PTX3) and vitamin D receptor (VDR) gene single nucleotide polymorphisms (SNPs) in susceptibility to pulmonary tuberculosis (TB) in 321 TB cases and 347 healthy controls from Guinea-Bissau. Five additional, functionally relevant SNPs...... within toll-like receptors (TLRs) 2, 4 and 9 were typed but found, when polymorphic, not to affect host vulnerability to pulmonary TB. We did not replicate an association between SNPs in the DC-SIGN promoter and TB. However, we found that two polymorphisms, one in DC-SIGN and one in VDR, were associated...

  17. DC-SIGN activation mediates the differential effects of SAP and CRP on the innate immune system and inhibits fibrosis in mice.

    Science.gov (United States)

    Cox, Nehemiah; Pilling, Darrell; Gomer, Richard H

    2015-07-07

    Fibrosis is caused by scar tissue formation in internal organs and is associated with 45% of deaths in the United States. Two closely related human serum proteins, serum amyloid P (SAP) and C-reactive protein (CRP), strongly affect fibrosis. In multiple animal models, and in Phase 1 and Phase 2 clinical trials, SAP affects several aspects of the innate immune system to reduce fibrosis, whereas CRP appears to potentiate fibrosis. However, SAP and CRP bind the same Fcγ receptors (FcγR) with similar affinities, and why SAP and CRP have opposing effects is unknown. Here, we report that SAP but not CRP binds the receptor DC-SIGN (SIGN-R1) to affect the innate immune system, and that FcγR are not necessary for SAP function. A polycyclic aminothiazole DC-SIGN ligand and anti-DC-SIGN antibodies mimic SAP effects in vitro. In mice, the aminothiazole reduces neutrophil accumulation in a model of acute lung inflammation and, at 0.001 mg/kg, alleviates pulmonary fibrosis by increasing levels of the immunosuppressant IL-10. DC-SIGN (SIGN-R1) is present on mouse lung epithelial cells, and SAP and the aminothiazole potentiate IL-10 production from these cells. Our data suggest that SAP activates DC-SIGN to regulate the innate immune system differently from CRP, and that DC-SIGN is a target for antifibrotics.

  18. R5 human immunodeficiency virus type 1 with efficient DC-SIGN use is not selected for early after birth in vertically infected children.

    Science.gov (United States)

    Borggren, Marie; Navér, Lars; Casper, Charlotte; Ehrnst, Anneka; Jansson, Marianne

    2013-04-01

    The binding of human immunodeficiency virus (HIV) to C-type lectin receptors may result in either enhanced trans-infection of T-cells or virus degradation. We have investigated the efficacy of HIV-1 utilization of DC-SIGN, a C-type lectin receptor, in the setting of intrauterine or intrapartum mother-to-child transmission (MTCT). Viruses isolated from HIV-1-infected mothers at delivery and from their vertically infected children both shortly after birth and later during the progression of the disease were analysed for their use of DC-SIGN, binding and ability to trans-infect. DC-SIGN use of a child's earlier virus isolate tended to be reduced as compared with that of the corresponding maternal isolate. Furthermore, the children's later isolate displayed enhanced DC-SIGN utilization compared with that of the corresponding earlier virus. These results were also supported in head-to-head competition assays and suggest that HIV-1 variants displaying efficient DC-SIGN use are not selected for during intrauterine or intrapartum MTCT. However, viruses with increased DC-SIGN use may evolve later in paediatric HIV-1 infections.

  19. Insights into molecular recognition of LewisX mimics by DC-SIGN using NMR and molecular modelling

    International Nuclear Information System (INIS)

    Guzzi, C.; Angulo, J.; Rojo, J.; Nieto, P.M.; Doro, F.; Bernardi, A.; Thepaut, M.; Fieschi, F.; Thepaut, M.; Fieschi, F.

    2011-01-01

    In this work, we have studied in detail the binding of two α-fucosyl-amide-based mimics of Lewis X to DC-SIGN ECD (ECD = extracellular domain) using STD NMR and docking. We have concluded that the binding mode occurs mainly through the fucose moiety, in the same way as Lewis X . Similarly to other mimics containing mannose or fucose previously studied, we have shown that both compounds bind to DC-SIGN ECD in a multimodal fashion. In this case, the main contact is the interaction of two hydroxyl groups one equatorial and the other one axial (O3 and O4) of the fucose with the Ca 2+ as Lewis X and similarly to mannose-containing mimics (in this case the interacting groups are both in the equatorial position). Finally, we have measured the K D of one mimic that was 0.4 mM. Competitive STD NMR experiments indicate that the aromatic moiety provides additional binding contacts that increase the affinity. (authors)

  20. Polymorphisms in DC-SIGN and L-SIGN genes are associated with HIV-1 vertical transmission in a Northeastern Brazilian population.

    Science.gov (United States)

    da Silva, Ronaldo Celerino; Segat, Ludovica; Zanin, Valentina; Arraes, Luiz Claudio; Crovella, Sergio

    2012-11-01

    DC-SIGN and L-SIGN are receptors expressed on specialized macrophages in decidua, (Hofbauer and placental capillary endothelial cells), known to interact with several pathogens, including HIV-1. To disclose the possible involvement of these molecules in the susceptibility to HIV vertical transmission, we analyzed DC-SIGN and L-SIGN gene single nucleotide polymorphisms (SNPs) in 192 HIV-1 positive children and 58 HIV-1 negative children all born to HIV-1 positive mothers, as well as 96 healthy uninfected children not exposed to HIV-1, all from Northeast Brazil. The frequency of three SNPs in the DC-SIGN promoter (-139G>A, -201G>T and -336A>G) were significantly different when comparing HIV positive children with HIV-1 exposed uninfected children, indicating an association with susceptibility to HIV-1 vertical transmission. This genetic association suggests that DC-SIGN molecule may play a role in susceptibility to HIV-1 infection through vertical transmission. Copyright © 2012 American Society for Histocompatibility and Immunogenetics. Published by Elsevier Inc. All rights reserved.

  1. AFM force spectroscopy reveals how subtle structural differences affect the interaction strength between Candida albicans and DC-SIGN

    NARCIS (Netherlands)

    Riet, J. te; Reinieren-Beeren, I.M.J.; Figdor, C.G.; Cambi, A.

    2015-01-01

    The fungus Candida albicans is the most common cause of mycotic infections in immunocompromised hosts. Little is known about the initial interactions between Candida and immune cell receptors, such as the C-type lectin dendritic cell-specific intracellular cell adhesion molecule-3 (ICAM-3)-grabbing

  2. Specific detection of proteins using Nanomechanical resonators

    DEFF Research Database (Denmark)

    Fischer, Lee MacKenzie; Wright, V.A.; Guthy, C.

    2008-01-01

    of probes onto their surfaces in order to enable the specificity of the detection. Such nanoresonator-based specific detection of proteins is here reported using streptavidin as target system, and immobilized biotin as probe. Nanomechanical resonators resistant to stiction were first realized from silicon...... carbonitride using a novel fabrication method. Vapor-phase deposition of mercaptopropyl trimethoxysilane was performed, and an added mass of 2.22 +/- 0.07 fg/mu m(2) was measured. This linker molecule was used to attach biotin onto the devices, enabling the specific detection of streptavidin. A mass of 3.6 fg....../mu m(2) was attributed to the added streptavidin, corresponding to one molecule per 27 nm(2). The specificity of this recognition was confirmed by exposing the devices to a solution of streptavidin that was already saturated with biotin. An additional negative control was also performed by also...

  3. Binding of HIV-1 gp120 to DC-SIGN promotes ASK-1-dependent activation-induced apoptosis of human dendritic cells.

    Directory of Open Access Journals (Sweden)

    Yongxiong Chen

    2013-01-01

    Full Text Available During disease progression to AIDS, HIV-1 infected individuals become increasingly immunosuppressed and susceptible to opportunistic infections. It has also been demonstrated that multiple subsets of dendritic cells (DC, including DC-SIGN⁺ cells, become significantly depleted in the blood and lymphoid tissues of AIDS patients, which may contribute to the failure in initiating effective host immune responses. The mechanism for DC depletion, however, is unclear. It is also known that vast quantities of viral envelope protein gp120 are shed from maturing HIV-1 virions and form circulating immune complexes in the serum of HIV-1-infected individuals, but the pathological role of gp120 in HIV-1 pathogenesis remains elusive. Here we describe a previously unrecognized mechanism of DC death in chronic HIV-1 infection, in which ligation of DC-SIGN by gp120 sensitizes DC to undergo accelerated apoptosis in response to a variety of activation stimuli. The cultured monocyte-derived DC and also freshly-isolated DC-SIGN⁺ blood DC that were exposed to either cross-linked recombinant gp120 or immune-complex gp120 in HIV⁺ serum underwent considerable apoptosis after CD40 ligation or exposure to bacterial lipopolysaccharide (LPS or pro-inflammatory cytokines such as TNFα and IL-1β. Furthermore, circulating DC-SIGN⁺ DC that were isolated directly from HIV-1⁺ individuals had actually been pre-sensitized by serum gp120 for activation-induced exorbitant apoptosis. In all cases the DC apoptosis was substantially inhibited by DC-SIGN blockade. Finally, we showed that accelerated DC apoptosis was a direct consequence of excessive activation of the pro-apoptotic molecule ASK-1 and transfection of siRNA against ASK-1 significantly prevented the activation-induced excessive DC death. Our study discloses a previously unknown mechanism of immune modulation by envelope protein gp120, provides new insights into HIV immunopathogenesis, and suggests potential

  4. COMPARATIVE STUDY ON SPECIFIC AND EARLY DETECTION ...

    African Journals Online (AJOL)

    The objective of this study was to compare the sensitivity and specificity of smear and culture methods with rapid serological EIA myco kits manufactured by Omega diagnostics, for the early detection of Mycobacterium tuberculosis (MTB) complex. Sera from various categories of smear and culture results were compared ...

  5. Human dendritic cell DC-SIGN and TLR-2 mediate complementary immune regulatory activities in response to Lactobacillus rhamnosus JB-1.

    Directory of Open Access Journals (Sweden)

    Patrycja Konieczna

    Full Text Available The microbiota is required for optimal host development and ongoing immune homeostasis. Lactobacilli are common inhabitants of the mammalian large intestine and immunoregulatory effects have been described for certain, but not all, strains. The mechanisms underpinning these protective effects are beginning to be elucidated. One such protective organism is Lactobacillus rhamnosus JB-1 (Lb. rhamnosus JB-1. Lb. murinus has no such anti-inflammatory protective effects and was used as a comparator organism. Human monocyte-derived dendritic cells (MDDCs were co-incubated with bacteria and analysed over time for bacterial adhesion and intracellular processing, costimulatory molecule expression, cytokine secretion and induction of lymphocyte polarization. Neutralising antibodies were utilized to identify the responsible MDDC receptors. Lb. rhamnosus JB-1 adhered to MDDCs, but internalization and intracellular processing was significantly delayed, compared to Lb. murinus which was rapidly internalized and processed. Lb. murinus induced CD80 and CD86 expression, accompanied by high levels of cytokine secretion, while Lb. rhamnosus JB-1 was a poor inducer of costimulatory molecule expression and cytokine secretion. Lb. rhamnosus JB-1 primed MDDCs induced Foxp3 expression in autologous lymphocytes, while Lb. murinus primed MDDCs induced Foxp3, T-bet and Ror-γt expression. DC-SIGN was required for Lb. rhamnosus JB-1 adhesion and influenced IL-12 secretion, while TLR-2 influenced IL-10 and IL-12 secretion. Here we demonstrate that the delayed kinetics of bacterial processing by MDDCs correlates with MDDC activation and stimulation of lymphocytes. Thus, inhibition or delay of intracellular processing may be a novel strategy by which certain commensals may avoid the induction of proinflammatory responses.

  6. Human Dendritic Cell DC-SIGN and TLR-2 Mediate Complementary Immune Regulatory Activities in Response to Lactobacillus rhamnosus JB-1

    Science.gov (United States)

    Konieczna, Patrycja; Schiavi, Elisa; Ziegler, Mario; Groeger, David; Healy, Selena; Grant, Ray; O’Mahony, Liam

    2015-01-01

    The microbiota is required for optimal host development and ongoing immune homeostasis. Lactobacilli are common inhabitants of the mammalian large intestine and immunoregulatory effects have been described for certain, but not all, strains. The mechanisms underpinning these protective effects are beginning to be elucidated. One such protective organism is Lactobacillus rhamnosus JB-1 (Lb. rhamnosus JB-1). Lb. murinus has no such anti-inflammatory protective effects and was used as a comparator organism. Human monocyte-derived dendritic cells (MDDCs) were co-incubated with bacteria and analysed over time for bacterial adhesion and intracellular processing, costimulatory molecule expression, cytokine secretion and induction of lymphocyte polarization. Neutralising antibodies were utilized to identify the responsible MDDC receptors. Lb. rhamnosus JB-1 adhered to MDDCs, but internalization and intracellular processing was significantly delayed, compared to Lb. murinus which was rapidly internalized and processed. Lb. murinus induced CD80 and CD86 expression, accompanied by high levels of cytokine secretion, while Lb. rhamnosus JB-1 was a poor inducer of costimulatory molecule expression and cytokine secretion. Lb. rhamnosus JB-1 primed MDDCs induced Foxp3 expression in autologous lymphocytes, while Lb. murinus primed MDDCs induced Foxp3, T-bet and Ror-γt expression. DC-SIGN was required for Lb. rhamnosus JB-1 adhesion and influenced IL-12 secretion, while TLR-2 influenced IL-10 and IL-12 secretion. Here we demonstrate that the delayed kinetics of bacterial processing by MDDCs correlates with MDDC activation and stimulation of lymphocytes. Thus, inhibition or delay of intracellular processing may be a novel strategy by which certain commensals may avoid the induction of proinflammatory responses. PMID:25816321

  7. Human dendritic cell DC-SIGN and TLR-2 mediate complementary immune regulatory activities in response to Lactobacillus rhamnosus JB-1.

    Science.gov (United States)

    Konieczna, Patrycja; Schiavi, Elisa; Ziegler, Mario; Groeger, David; Healy, Selena; Grant, Ray; O'Mahony, Liam

    2015-01-01

    The microbiota is required for optimal host development and ongoing immune homeostasis. Lactobacilli are common inhabitants of the mammalian large intestine and immunoregulatory effects have been described for certain, but not all, strains. The mechanisms underpinning these protective effects are beginning to be elucidated. One such protective organism is Lactobacillus rhamnosus JB-1 (Lb. rhamnosus JB-1). Lb. murinus has no such anti-inflammatory protective effects and was used as a comparator organism. Human monocyte-derived dendritic cells (MDDCs) were co-incubated with bacteria and analysed over time for bacterial adhesion and intracellular processing, costimulatory molecule expression, cytokine secretion and induction of lymphocyte polarization. Neutralising antibodies were utilized to identify the responsible MDDC receptors. Lb. rhamnosus JB-1 adhered to MDDCs, but internalization and intracellular processing was significantly delayed, compared to Lb. murinus which was rapidly internalized and processed. Lb. murinus induced CD80 and CD86 expression, accompanied by high levels of cytokine secretion, while Lb. rhamnosus JB-1 was a poor inducer of costimulatory molecule expression and cytokine secretion. Lb. rhamnosus JB-1 primed MDDCs induced Foxp3 expression in autologous lymphocytes, while Lb. murinus primed MDDCs induced Foxp3, T-bet and Ror-γt expression. DC-SIGN was required for Lb. rhamnosus JB-1 adhesion and influenced IL-12 secretion, while TLR-2 influenced IL-10 and IL-12 secretion. Here we demonstrate that the delayed kinetics of bacterial processing by MDDCs correlates with MDDC activation and stimulation of lymphocytes. Thus, inhibition or delay of intracellular processing may be a novel strategy by which certain commensals may avoid the induction of proinflammatory responses.

  8. Prostatic specific antigen for prostate cancer detection

    Directory of Open Access Journals (Sweden)

    Lucas Nogueira

    2009-10-01

    Full Text Available Prostate-specific antigen (PSA has been used for prostate cancer detection since 1994. PSA testing has revolutionized our ability to diagnose, treat, and follow-up patients. In the last two decades, PSA screening has led to a substantial increase in the incidence of prostate cancer (PC. This increased detection caused the incidence of advanced-stage disease to decrease at a dramatic rate, and most newly diagnosed PC today are localized tumors with a high probability of cure. PSA screening is associated with a 75% reduction in the proportion of men who now present with metastatic disease and a 32.5% reduction in the age-adjusted prostate cancer mortality rate through 2003. Although PSA is not a perfect marker, PSA testing has limited specificity for prostate cancer detection, and its appropriate clinical application remains a topic of debate. Due to its widespread use and increased over-detection, the result has been the occurrence of over-treatment of indolent cancers. Accordingly, several variations as regards PSA measurement have emerged as useful adjuncts for prostate cancer screening. These procedures take into consideration additional factors, such as the proportion of different PSA isoforms (free PSA, complexed PSA, pro-PSA and B PSA, the prostate volume (PSA density, and the rate of change in PSA levels over time (PSA velocity or PSA doubling time. The history and evidence underlying each of these parameters are reviewed in the following article.

  9. Prostatic specific antigen for prostate cancer detection.

    Science.gov (United States)

    Nogueira, Lucas; Corradi, Renato; Eastham, James A

    2009-01-01

    Prostate-specific antigen (PSA) has been used for prostate cancer detection since 1994. PSA testing has revolutionized our ability to diagnose, treat, and follow-up patients. In the last two decades, PSA screening has led to a substantial increase in the incidence of prostate cancer (PC). This increased detection caused the incidence of advanced-stage disease to decrease at a dramatic rate, and most newly diagnosed PC today are localized tumors with a high probability of cure. PSA screening is associated with a 75% reduction in the proportion of men who now present with metastatic disease and a 32.5% reduction in the age-adjusted prostate cancer mortality rate through 2003. Although PSA is not a perfect marker, PSA testing has limited specificity for prostate cancer detection, and its appropriate clinical application remains a topic of debate. Due to its widespread use and increased over-detection, the result has been the occurrence of over-treatment of indolent cancers. Accordingly, several variations as regards PSA measurement have emerged as useful adjuncts for prostate cancer screening. These procedures take into consideration additional factors, such as the proportion of different PSA isoforms (free PSA, complexed PSA, pro-PSA and B PSA), the prostate volume (PSA density), and the rate of change in PSA levels over time (PSA velocity or PSA doubling time). The history and evidence underlying each of these parameters are reviewed in the following article.

  10. Molecules for Fluorescence Detection of Specific Chemicals

    Science.gov (United States)

    Fedor, Steve

    2008-01-01

    A family of fluorescent dye molecules has been developed for use in on-off fluorescence detection of specific chemicals. By themselves, these molecules do not fluoresce. However, when exposed to certain chemical analytes in liquid or vapor forms, they do fluoresce (see figure). These compounds are amenable to fixation on or in a variety of substrates for use in fluorescence-based detection devices: they can be chemically modified to anchor them to porous or non-porous solid supports or can be incorporated into polymer films. Potential applications for these compounds include detection of chemical warfare agents, sensing of acidity or alkalinity, and fluorescent tagging of proteins in pharmaceutical research and development. These molecules could also be exploited for use as two-photon materials for photodynamic therapy in the treatment of certain cancers and other diseases. A molecule in this family consists of a fluorescent core (such as an anthracene or pyrene) attached to two end groups that, when the dye is excited by absorption of light, transfer an electron to the core, thereby quenching the fluorescence. The end groups can be engineered so that they react chemically with certain analytes. Upon reaction, electrons on the end groups are no longer available for transfer to the core and, consequently, the fluorescence from the core is no longer quenched. The chemoselectivity of these molecules can be changed by changing the end groups. For example, aniline end groups afford a capability for sensing acids or acid halides (including those contained in chemical warfare agents). Pyridine or bipyridyl end groups would enable sensing of metal ions. Other chemicals that can be selectively detected through suitable choice of end groups include glucose and proteins. Moreover, the fluorescent cores can be changed to alter light-absorption and -emission characteristics: anthracene cores fluoresce at wavelengths around 500 nm, whereas perylene cores absorb and emit at

  11. Tumor specific glycoproteins and method for detecting tumorigenic cancers

    International Nuclear Information System (INIS)

    Davidson, E.A.; Bolmer, S.D.

    1981-01-01

    The detection of tumour specific glycoproteins (TSGP) in human sera often indicates the presence of a malignant tumour in a patient. The distinguishing characteristics of TSGP isolated from the blood sera of cancer patients are described in detail together with methods of TSGP isolation and purification. Details are also given of radioimmunoassay techniques capable of detecting very low levels of serum TSGP with high specificity. (U.K.)

  12. Allele-Specific DNA Methylation Detection by Pyrosequencing®

    DEFF Research Database (Denmark)

    Kristensen, Lasse Sommer; Johansen, Jens Vilstrup; Grønbæk, Kirsten

    2015-01-01

    DNA methylation is an epigenetic modification that plays important roles in healthy as well as diseased cells, by influencing the transcription of genes. In spite the fact that human somatic cells are diploid, most of the currently available methods for the study of DNA methylation do not provide......-effective protocol for allele-specific DNA methylation detection based on Pyrosequencing(®) of methylation-specific PCR (MSP) products including a single nucleotide polymorphism (SNP) within the amplicon....

  13. Specific detection of Aspergillus fumigatus in sputum sample of ...

    African Journals Online (AJOL)

    We developed a two-step PCR assay that specifically amplifies a region of the 18S rRNA gene that is highly conserved in Aspergillus fumigatus. This assay allows direct and rapid detection of down to 10 fg of Aspergillus fumigatus DNA corresponding to 1 to 5 colony forming unit (CFU) per ml of sputum sample of pulmonary ...

  14. Chromosome-specific staining to detect genetic rearrangements

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Joe W.; Pinkel, Daniel; Tkachuk, Douglas; Westbrook, Carol

    2013-04-09

    Methods and compositions for staining based upon nucleic acid sequence that employ nucleic acid probes are provided. Said methods produce staining patterns that can be tailored for specific cytogenetic analyzes. Said probes are appropriate for in situ hybridization and stain both interphase and metaphase chromosomal material with reliable signals. The nucleic acid probes are typically of a complexity greater than 50 kb, the complexity depending upon the cytogenetic application. Methods and reagents are provided for the detection of genetic rearrangements. Probes and test kits are provided for use in detecting genetic rearrangements, particularly for use in tumor cytogenetics, in the detection of disease related loci, specifically cancer, such as chronic myelogenous leukemia (CML) and for biological dosimetry. Methods and reagents are described for cytogenetic research, for the differentiation of cytogenetically similar but genetically different diseases, and for many prognostic and diagnostic applications.

  15. Improved patient specific seizure detection during pre-surgical evaluation.

    LENUS (Irish Health Repository)

    Chua, Eric C-P

    2011-04-01

    There is considerable interest in improved off-line automated seizure detection methods that will decrease the workload of EEG monitoring units. Subject-specific approaches have been demonstrated to perform better than subject-independent ones. However, for pre-surgical diagnostics, the traditional method of obtaining a priori data to train subject-specific classifiers is not practical. We present an alternative method that works by adapting the threshold of a subject-independent to a specific subject based on feedback from the user.

  16. Investigation of contactless detection using a giant magnetoresistance sensor for detecting prostate specific antigen.

    Science.gov (United States)

    Sun, Xuecheng; Zhi, Shaotao; Lei, Chong; Zhou, Yong

    2016-08-01

    This paper presents a contactless detection method for detecting prostate specific antigen with a giant magnetoresistance sensor. In contactless detection case, the prostate specific antigen sample preparation was separated from the sensor that prevented the sensor from being immersed in chemical solvents, and made the sensor implementing in immediately reuse without wash. Experimental results showed that applied an external magnetic field in a range of 50 Oe to 90 Oe, Dynabeads with a concentration as low as 0.1 μg/mL can be detected by this system and could give an approximate quantitation to the logarithmic of Dynabeads concentration. Sandwich immunoassay was employed for preparing PSA samples. The PSA capture was implemented on a gold film modified with a self-assembled monolayer and using biotinylated secondary antibody against PSA and streptavidinylated Dynabeads. With DC magnetic field in the range of 50 to 90 Oe, PSA can be detected with a detection limit as low as 0.1 ng/mL. Samples spiked with different concentrations of PSA can be distinguished clearly. Due to the contactless detection method, the detection system exhibited advantages such as convenient manipulation, reusable, inexpensive, small weight. So, this detection method was a promising candidate in biomarker detection, especially in point of care detection.

  17. A printed electronic platform for the specific detection of biomolecules

    Science.gov (United States)

    Doumbia, A.; Webb, M.; Turner, M. L.; Behrendt, J. M.; Wilson, R.

    2017-08-01

    The rapid detection of disease specific biomarkers in a clinically relevant range using a low-cost sensor can facilitate the development of individual treatment plans for a given patient, known as precision, personalized or genomic medicine. In the recent decade Electrolyte-Gated Organic Field Effect Transistors (EGOFETs), a subtype of OFETs where the dielectric is replaced by an electrolyte, have attracted a great deal of attention for sensing applications. This is due to their capacity to operate at low voltage (market are not yet achieved. In this contribution, we describe the development of a stable and reproducible EGOFET sensor that is able to detect biomolecules selectively in real-time. Facile and scalable techniques are used to prepare arrays of these devices. The selectivity of individual EGOFETs is investigated by immobilization of specific ligands to the target molecule of interest on the gate electrode within a microfluidic flow cell.

  18. Detection of site specific glycosylation in proteins using flow cytometry†

    Science.gov (United States)

    Jayakumar, Deepak; Marathe, Dhananjay D.; Neelamegham, Sriram

    2009-01-01

    We tested the possibility that it is possible to express unique peptide probes on cell surfaces and detect site-specific glycosylation on these peptides using flow cytometry. Such development can enhance the application of flow cytometry to detect and quantify post-translational modifications in proteins. To this end, the N-terminal section of the human leukocyte glycoprotein PSGL-1 (P-selectin glycoprotein ligand-1) was modified to contain a poly-histidine tag followed by a proteolytic cleavage site. Amino acids preceding the cleavage site have a single O-linked glycosylation site. The recombinant protein called PSGL-1 (HT) was expressed on the surface of two mammalian cell lines, CHO and HL-60, using a lentiviral delivery approach. Results demonstrate that the N-terminal portion of PSGL-1 (HT) can be released from these cells by protease, and the resulting peptide can be readily captured and detected using cytometry-bead assays. Using this strategy, the peptide was immunoprecipitated onto beads bearing mAbs against either the poly-histidine sequence or the human PSGL-1. The carbohydrate epitope associated with the released peptide was detected using HECA-452 and CSLEX-1, monoclonal antibodies that recognize the sialyl Lewis-X epitope. Finally, the peptide released from cells could be separated and enriched using nickel chelate beads. Overall, such an approach that combines recombinant protein expression with flow cytometry, may be useful to quantify changes in site-specific glycosylation for basic science and clinical applications. PMID:19735085

  19. Sensitive, Fast, and Specific Immunoassays for Methyltestosterone Detection

    Directory of Open Access Journals (Sweden)

    Na Kong

    2015-04-01

    Full Text Available An indirect competitive enzyme-linked immunosorbent assay (icELISA and an immunochromatographic strip assay using a highly specific monoclonal antibody, were developed to detect methyltestosterone (MT residues in animal feed. The optimized icELISA had a half-inhibition concentration value of 0.26 ng/mL and a limit of detection value of 0.045 ng/mL. There was no cross-reactivity with eight analogues, revealing high specificity for MT. Based on icELISA results, the recovery rate of MT in animal feed was 82.4%–100.6%. The results were in accordance with those obtained by gas chromatography-mass spectrometry. The developed immunochromatographic strip assay, as the first report for MT detection, had a visual cut-off value of 1 ng/mL in PBS, 2.5 ng/g in fish feed, and 2.5 ng/g in pig feed. Therefore, these immunoassays are useful and fast tools for MT residue detection in animal feed.

  20. Recent development of fluorescent imaging for specific detection of tumors

    International Nuclear Information System (INIS)

    Nakata, Eiji; Morii, Takashi; Uto, Yoshihiro; Hori, Hitoshi

    2011-01-01

    Increasing recent studies on fluorescent imaging for specific detection of tumors are described here on strategies of molecular targeting, metabolic specificity and hypoxic circumstance. There is described an instance of a conjugate of antibody and pH-activable fluorescent ligand, which specifically binds to the tumor cells, is internalized in the cellular lysozomes where their pH is low, and then is activated to become fluorescent only in viable tumor cells. For the case of metabolic specificity, excessive loading of the precursor (5-aminolevulinic acid) of protoporphyrin IX (ppIX), due to their low activity to convert ppIX to heme B, results in making tumors observable in red as ppIX emits fluorescence (red, 585 nm) when excited by blue ray of 410 nm. Similarly, imaging with indocyanine green which is accumulated in hepatoma cells is reported in success in detection of small lesion and metastasis when the dye is administered during operation. Reductive reactions exceed in tumor hypoxic conditions, of which feature is usable for imaging. Conjugates of nitroimidazole and fluorescent dye are reported to successfully image tumors by nitro reduction. Authors' UTX-12 is a non-fluorescent nitroaromatic derivative of pH-sensitive fluorescent dye seminaphtharhodafluor (SNARF), and is designed for the nitro group, the hypoxia-responding sensor, to be reduced in tumor hypoxic conditions and then for the aromatic moiety to be cleaved to release free SNARF. Use of hypoxia-inducible factor-1 (HIF-1) for imaging has been also reported in many. As above, studies on fluorescent imaging for specific detection of tumors are mostly at fundamental step but its future is conceivably promising along with advances in other technology like fluorescent endoscopy and multimodal imaging. (author)

  1. Micro solid-phase radioimmunoassay for detection of herpesvirus type-specific antibody: specificity and sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Adler-Storthz, K.; Matson, D.O.; Adam, E.; Dreesman, G.R. (Baylor Univ., Houston, TX (USA). Coll. of Medicine)

    1983-02-01

    The specificity and sensitivity of a micro solid-phase radioimmunoassay (micro-SPRIA) that detects type-specific IgG antibody to herpes simplex virus types 1 and 2 (HSV1 and HSV2) were evaluated. Glycoproteins VP123 (molecular weight, 123,000) of HSV1 and VP119 (molecular weight, 119,000) of HSV2 were found to display the greatest degree of antigenic type-specificity of several HSV antigens tested with the micro-SPRIA technique. When testing a group of sera, negative for anti-HSV antibodies by microneutralization, in the micro-SPRIA, a range of negative reactivities was noted, suggesting that cut-points should be determined for each antigen preparation. The micro-SPRIA detected appropriate antibody activity in patients with recurrent infection and a marked agreement was noted in comparison to detection of anti-HSV antibodies measured with the microneutralization test. The type-specificity of the micro-SPRIA was substantiated by the independence of test results using VP119 and VP123 antigens for a random group of positive sera. The assay is rapid, specific, and sensitive and allows the testing of multiple serum samples with a standardized set of reagents.

  2. Specific and ultrasensitive ciprofloxacin detection by responsive photonic crystal sensor

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Rong; Wang, Yong [Department of Chemistry, School of Science, Tianjin University, Tianjin 300072 (China); Yu, Li-Ping, E-mail: lipingyu@tju.edu.cn [Department of Chemistry, School of Science, Tianjin University, Tianjin 300072 (China); State Key Laboratory of Medicinal Chemical Biology, Nankai University, Tianjin 300071 (China)

    2014-09-15

    Highlights: • Sensor was designed by integrating complexes into responsive photonic crystal. • Ternary tryptophan–zinc(II)–ciprofloxacin complexes were chosen for sensing. • Excellent sensing of ciprofloxacin was achieved in aqueous media. - Abstract: A new approach for specific and ultrasensitive measurement of ciprofloxacin has been developed by integrating ternary complexes into responsive photonic crystal (RPC). Tryptophan was first immobilized within the polyacrylamide hydrogel substrates of RPC. The determination of ciprofloxacin was via the existence of zinc(II) ions that function as a ‘bridge’ to form specific tryptophan–zinc(II)–ciprofloxacin complexes step by step, which resulted in a stepwise red-shift of the diffraction wavelength. A maximum wavelength shift from 798 to 870 nm for ciprofloxacin was observed when the RPC film was immersed in 10{sup −4} M ciprofloxacin. A linear relationship has been obtained between the Δλ of diffraction peak and logarithm of ciprofloxacin concentration at pH 5.0 in the range of 10{sup −10} to 10{sup −4} M. And the least detectable concentration in present work is about 5 × 10{sup −11} M. The results demonstrated that the as-designed ternary complexes-based RPC sensor exhibited high sensitivity, satisfactory specificity and excellent recoverability for sensing of ciprofloxacin in aqueous media and were validated by detecting ciprofloxacin in the eye-drop sample.

  3. Detection of mutations in genes by specific LNA primers

    DEFF Research Database (Denmark)

    2001-01-01

    acid (LNA). LNA oligomers obey the Watson-Crick base-pairing rules and form duplexes that are significantly more stable than similar duplexes formed by DNA. The "allele-specific" LNA-containing oligonucleotides wherein the LNA nucleotide(s) are found at the 3' position can be extended by means......The present invention relates to a method of detecting variant nucleic acid whose nucleotide sequence differs from one another at a single (or more) position(s). The method uses a set of chimeric oligonucleotides containing DNA monomers and monomers of a novel class of DNA analogues, locked nucleic...

  4. Unsupervised behaviour-specific dictionary learning for abnormal event detection

    DEFF Research Database (Denmark)

    Ren, Huamin; Liu, Weifeng; Olsen, Søren Ingvor

    2015-01-01

    the training data is only a small proportion of the surveillance data. Therefore, we propose behavior-specific dictionaries (BSD) through unsupervised learning, pursuing atoms from the same type of behavior to represent one behavior dictionary. To further improve the dictionary by introducing information from...... potential infrequent normal patterns, we refine the dictionary by searching ‘missed atoms’ that have compact coefficients. Experimental results show that our BSD algorithm outperforms state-of-the-art dictionaries in abnormal event detection on the public UCSD dataset. Moreover, BSD has less false alarms...

  5. Real-time prostate-specific antigen detection with prostate-specific antigen imprinted capacitive biosensors

    Energy Technology Data Exchange (ETDEWEB)

    Ertürk, Gizem [Department of Biotechnology, Lund University, Lund (Sweden); Department of Biology, Hacettepe University, Ankara (Turkey); Hedström, Martin [Department of Biotechnology, Lund University, Lund (Sweden); CapSenze HB, Medicon Village, SE-223 63 Lund (Sweden); Tümer, M. Aşkın [Department of Biology, Hacettepe University, Ankara (Turkey); Denizli, Adil [Department of Chemistry, Hacettepe University, Ankara (Turkey); Mattiasson, Bo, E-mail: Bo.Mattiasson@biotek.lu.se [Department of Biotechnology, Lund University, Lund (Sweden); CapSenze HB, Medicon Village, SE-223 63 Lund (Sweden)

    2015-09-03

    Prostate specific antigen (PSA) is a valuable biomarker for early detection of prostate cancer, the third most common cancer in men. Ultrasensitive detection of PSA is crucial to screen the prostate cancer in an early stage and to detect the recurrence of the disease after treatment. In this report, microcontact-PSA imprinted (PSA-MIP) capacitive biosensor chip was developed for real-time, highly sensitive and selective detection of PSA. PSA-MIP electrodes were prepared in the presence of methacrylic acid (MAA) as the functional monomer and ethylene glycol dimethacrylate (EGDMA) as the cross-linker via UV polymerization. Immobilized Anti-PSA antibodies on electrodes (Anti-PSA) for capacitance measurements were also prepared to compare the detection performances of both methods. The electrodes were characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM) and cyclic voltammetry (CV) and real-time PSA detection was performed with standard PSA solutions in the concentration range of 10 fg mL{sup −1}–100 ng mL{sup −1}. The detection limits were found as 8.0 × 10{sup −5} ng mL{sup −1} (16 × 10{sup −17} M) and 6.0 × 10{sup −4} ng mL{sup −1} (12 × 10{sup −16} M) for PSA-MIP and Anti-PSA electrodes, respectively. Selectivity studies were performed against HSA and IgG and selectivity coefficients were calculated. PSA detection was also carried out from diluted human serum samples and finally, reproducibility of the electrodes was tested. The results are promising and show that when the sensitivity of the capacitive system is combined with the selectivity and reproducibility of the microcontact-imprinting procedure, the resulting system might be used successfully for real-time detection of various analytes even in very low concentrations. - Highlights: • Microcontact imprinting method was used for preparing the sensor chip for capacitive biosensing. • High sensitivity was obtained. • Good selectivity was

  6. Real-time prostate-specific antigen detection with prostate-specific antigen imprinted capacitive biosensors

    International Nuclear Information System (INIS)

    Ertürk, Gizem; Hedström, Martin; Tümer, M. Aşkın; Denizli, Adil; Mattiasson, Bo

    2015-01-01

    Prostate specific antigen (PSA) is a valuable biomarker for early detection of prostate cancer, the third most common cancer in men. Ultrasensitive detection of PSA is crucial to screen the prostate cancer in an early stage and to detect the recurrence of the disease after treatment. In this report, microcontact-PSA imprinted (PSA-MIP) capacitive biosensor chip was developed for real-time, highly sensitive and selective detection of PSA. PSA-MIP electrodes were prepared in the presence of methacrylic acid (MAA) as the functional monomer and ethylene glycol dimethacrylate (EGDMA) as the cross-linker via UV polymerization. Immobilized Anti-PSA antibodies on electrodes (Anti-PSA) for capacitance measurements were also prepared to compare the detection performances of both methods. The electrodes were characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM) and cyclic voltammetry (CV) and real-time PSA detection was performed with standard PSA solutions in the concentration range of 10 fg mL"−"1–100 ng mL"−"1. The detection limits were found as 8.0 × 10"−"5 ng mL"−"1 (16 × 10"−"1"7 M) and 6.0 × 10"−"4 ng mL"−"1 (12 × 10"−"1"6 M) for PSA-MIP and Anti-PSA electrodes, respectively. Selectivity studies were performed against HSA and IgG and selectivity coefficients were calculated. PSA detection was also carried out from diluted human serum samples and finally, reproducibility of the electrodes was tested. The results are promising and show that when the sensitivity of the capacitive system is combined with the selectivity and reproducibility of the microcontact-imprinting procedure, the resulting system might be used successfully for real-time detection of various analytes even in very low concentrations. - Highlights: • Microcontact imprinting method was used for preparing the sensor chip for capacitive biosensing. • High sensitivity was obtained. • Good selectivity was demonstrated. • Stability of

  7. Detection and specifity of class specific antibodies to whole bacteria cells using a solid phase radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Czerkinsky, C.; Rees, A.S.; Bergimeier, L.A.; Challacombe, S.J. (Guy' s Hospital Medical and Dental Schools, London (UK))

    1983-07-01

    A solid phase radioimmunoassay has been developed which can be used for the detection of isotype specific antibodies to whole bacteria and other particulate antigens, and is applicable to a variety of species. Bacteria are bound to the solid phase by the use either of antibodies, or of methyl glyoxal. Both methods result in a sensitive and reproducible assay, and bacteria do not appear to desorb from the solid phase. The specificity of antibodies to whole bacteria was examined by absorption of antisera with various species of bacteria and retesting, or by determining the binding of antisera to various bacteria bound to the solid phase. Both methods revealed specificity for the bacteria examined. Inhibition studies showed that antibodies to Streptococcus mutans whole cells could be inhibited by purified cell surface antigens glucosyltransferase and antigen I/II, but only minimally by lipoteichoic acid, c polysaccharide or dextran. In murine antisera antibodies of the IgG, IgM, and IgA classes could be detected at amounts of less than 1 ng/ml.

  8. Statistical text classifier to detect specific type of medical incidents.

    Science.gov (United States)

    Wong, Zoie Shui-Yee; Akiyama, Masanori

    2013-01-01

    WHO Patient Safety has put focus to increase the coherence and expressiveness of patient safety classification with the foundation of International Classification for Patient Safety (ICPS). Text classification and statistical approaches has showed to be successful to identifysafety problems in the Aviation industryusing incident text information. It has been challenging to comprehend the taxonomy of medical incidents in a structured manner. Independent reporting mechanisms for patient safety incidents have been established in the UK, Canada, Australia, Japan, Hong Kong etc. This research demonstrates the potential to construct statistical text classifiers to detect specific type of medical incidents using incident text data. An illustrative example for classifying look-alike sound-alike (LASA) medication incidents using structured text from 227 advisories related to medication errors from Global Patient Safety Alerts (GPSA) is shown in this poster presentation. The classifier was built using logistic regression model. ROC curve and the AUC value indicated that this is a satisfactory good model.

  9. Can hyperspectral remote sensing detect species specific biochemicals?

    Science.gov (United States)

    Discrimination of a few plants scattered among many plants is a goal common to detection of agricultural weeds and invasive species. Detection of clandestinely grown Cannabis sativa L. is in many ways a special case of weed detection. Remote sensing technology provides an automated, computer based,...

  10. A simple and sensitive fluorescent probe for specific detection of ...

    Indian Academy of Sciences (India)

    Yan-Fei Kang

    A fluorescent probe, with simplicity of structure and convenience of synthesis, is capable of detecting ... Yan-Fei Kang et al. .... Pastore A, Federici G, Bertini E and Ptemonte F 2003 ... Urano Y 2010 New Strategies for Fluorescent Probe.

  11. Sensitivity and Specificity of Cystatin C in Detecting Early Renal ...

    African Journals Online (AJOL)

    Purpose: To determine the cutoff point of cystatin C for the detection of renal impairment in hypertensive pregnancies. Methods: A cross-sectional study was conducted in an antenatal clinic and ward at Hospital Universiti Sains Malaysia, Kelantan, Malaysia from January 2009 until January 2010. Sixty four pregnant patients ...

  12. Sensitivity and Specificity of Cystatin C in Detecting Early Renal ...

    African Journals Online (AJOL)

    trimester since it maximizes the value of sensitivity and specificity. Keywords: Cystatin C ... Recruitment was done on patients that meet the inclusion and exclusion ... mm Hg. CKD stage was defined based on creatinine clearance value.

  13. New radionuclide specific laboratory detection system for metallurgical industry

    International Nuclear Information System (INIS)

    Burianova, L.; Solc, J.; Dryak, P.; Moser, H.; Branger, T.; Garcia-Torano, E.; Peyres, V.; Capogni, M.; Luca, A.; Vodenik, B.; Oliveira, C.; Portugal, L.; Tzika, F.; Lutter, G.; Szucs, L.; Dziel, T.; Burda, O.; Dirk, A.; Martinkovic, J.; Sliskonen, T.; Mattila, A.

    2014-01-01

    One of the main outputs of the European Metrology Research Programme (EMRP) project 'Ionising radiation metrology for the metallurgical industry' (MetroMetal) was the recommendation on a novel spectrometric detection system optimized for the measurement of radioactivity in metallurgical samples. The recommended system, prototypes of which were constructed at two project partner's laboratories, was characterized by using Monte Carlo (MC) simulations. Six different MC codes were used to model the system and a range of cylindrical samples of cast steel, slag and fume dust. The samples' shape, density, and elemental composition were the same as the ones of the calibration standards developed within the project to provide traceability to end-users. The MC models were used to calculate full-energy peak and total detection efficiencies as well as true coincidence summing correction (TCSC) factors for selected radionuclides of interest in the metallurgical industry: 60 Co, 137 Cs, 192 Ir, 214 Bi, 214 Pb, and 208 Tl. The MC codes were compared to each other on the basis of the calculated detection efficiencies and TCSC factors. In addition, a 'Procedural guide for calculation of TCSC factors for samples in metallurgical industry' was developed for end-users. The TCSC factors reached in certain cases up to 32% showing that the summing effects are of high importance in the close measurement geometries met in routine analysis of metallurgical samples. (authors)

  14. Detection of an occult hepatocellular carcinoma using ultrasound with liver-specific microbubbles

    International Nuclear Information System (INIS)

    Harvey, Christopher J.; Lim, Adrian K.P.; Blomley, Martin J.K.; Cosgrove, David O.; Taylor-Robinson, Simon D.; Gedroyc, Wladyslaw M.W.

    2002-01-01

    The radiological surveillance of cirrhosis to detect the development of hepatocellular carcinoma (HCC) is problematic because no highly sensitive and specific imaging investigation is available. Ultrasound is typically the first modality used but is less accurate than other imaging modalities. We report the first case of a patient with cirrhosis in whom US imaging with liver-specific microbubbles detected an HCC prior to its detection by MR. The use of liver-specific microbubble US contrast agents is an exciting development in the detection of HCC in chronic liver disease and may help to rectify some of the shortcomings of US. (orig.)

  15. High Specificity of Quantitative Methylation-Specific PCR Analysis for MGMT Promoter Hypermethylation Detection in Gliomas

    Directory of Open Access Journals (Sweden)

    Paola Parrella

    2009-01-01

    Full Text Available Normal brain tissue from 28 individuals and 50 glioma samples were analyzed by real-time Quantitative Methylation-Specific PCR (QMSP. Data from this analysis were compared with results obtained on the same samples by MSP. QMSP analysis demonstrated a statistically significant difference in both methylation level (P=.000009 Mann Whitney Test and frequencies (P=.0000007, Z-test in tumour samples as compared with normal brain tissues. Although QMSP and MSP showed similar sensitivity, the specificity of QMSP analysis was significantly higher (93%; CI95%: 84%–100% as compared with MSP (64%; 95%CI: 46%–82%. Our results suggest that QMSP analysis may represent a powerful tool to identify glioma patients that will benefit from alkylating agents chemotherapy.

  16. Neighbor Detection Induces Organ-Specific Transcriptomes, Revealing Patterns Underlying Hypocotyl-Specific Growth.

    Science.gov (United States)

    Kohnen, Markus V; Schmid-Siegert, Emanuel; Trevisan, Martine; Petrolati, Laure Allenbach; Sénéchal, Fabien; Müller-Moulé, Patricia; Maloof, Julin; Xenarios, Ioannis; Fankhauser, Christian

    2016-12-01

    In response to neighbor proximity, plants increase the growth of specific organs (e.g., hypocotyls) to enhance access to sunlight. Shade enhances the activity of Phytochrome Interacting Factors (PIFs) by releasing these bHLH transcription factors from phytochrome B-mediated inhibition. PIFs promote elongation by inducing auxin production in cotyledons. In order to elucidate spatiotemporal aspects of the neighbor proximity response, we separately analyzed gene expression patterns in the major light-sensing organ (cotyledons) and in rapidly elongating hypocotyls of Arabidopsis thaliana PIFs initiate transcriptional reprogramming in both organs within 15 min, comprising regulated expression of several early auxin response genes. This suggests that hypocotyl growth is elicited by both local and distal auxin signals. We show that cotyledon-derived auxin is both necessary and sufficient to initiate hypocotyl growth, but we also provide evidence for the functional importance of the local PIF-induced response. With time, the transcriptional response diverges increasingly between organs. We identify genes whose differential expression may underlie organ-specific elongation. Finally, we uncover a growth promotion gene expression signature shared between different developmentally regulated growth processes and responses to the environment in different organs. © 2016 American Society of Plant Biologists. All rights reserved.

  17. Preparation of genosensor for detection of specific DNA sequence of the hepatitis B virus

    International Nuclear Information System (INIS)

    Honorato Castro, Ana C.; França, Erick G.; Paula, Lucas F. de; Soares, Marcia M.C.N.; Goulart, Luiz R.; Madurro, João M.; Brito-Madurro, Ana G.

    2014-01-01

    Graphical abstract: - Highlights: • Specific oligonucleotide detection for hepatitis B based on poly-4-aminophenol matrix. • Electrochemical detection of the gene specific using ethidium bromide as indicator. • The detection limit was 2.61 nmol L −1 , with a correlation coefficient of 0.998 (n = 3). • The system discriminates three-base mismatches and non-complementary target. - Abstract: An electrochemical genosensor was constructed for detection of specific DNA sequence of the hepatitis B virus, based on graphite electrodes modified with poly(4-aminophenol) and incorporating a specific oligonucleotide probe. The modified electrode containing the probe was evaluated by differential pulse voltammetry, before and after incubation with the complementary oligonucleotide target. Detection was performed by monitoring oxidizable DNA bases (direct detection) or using ethidium bromide as indicator of the hybridization process (indirect detection). The device showed a detection limit for the oligonucleotide target of 2.61 nmol L −1 . Indirect detection using ethidium bromide was promising in discriminating mismatches, which is a very desirable attribute for detection of disease-related point mutations. In addition, it was possible to observe differences between hybridized and non-hybridized surfaces by atomic force microscopy

  18. Preparation of genosensor for detection of specific DNA sequence of the hepatitis B virus

    Energy Technology Data Exchange (ETDEWEB)

    Honorato Castro, Ana C.; França, Erick G. [Institute of Genetics and Biochemistry, Federal University of Uberlândia, Uberlândia (Brazil); Paula, Lucas F. de [Institute of Chemistry, Federal University of Uberlândia, Uberlândia (Brazil); Soares, Marcia M.C.N. [Adolfo Lutz Institute, Regional Laboratory in São José do Rio Preto (Brazil); Goulart, Luiz R. [Institute of Genetics and Biochemistry, Federal University of Uberlândia, Uberlândia (Brazil); Madurro, João M. [Institute of Chemistry, Federal University of Uberlândia, Uberlândia (Brazil); Brito-Madurro, Ana G., E-mail: agbrito@iqufu.ufu.br [Institute of Genetics and Biochemistry, Federal University of Uberlândia, Uberlândia (Brazil)

    2014-09-30

    Graphical abstract: - Highlights: • Specific oligonucleotide detection for hepatitis B based on poly-4-aminophenol matrix. • Electrochemical detection of the gene specific using ethidium bromide as indicator. • The detection limit was 2.61 nmol L{sup −1}, with a correlation coefficient of 0.998 (n = 3). • The system discriminates three-base mismatches and non-complementary target. - Abstract: An electrochemical genosensor was constructed for detection of specific DNA sequence of the hepatitis B virus, based on graphite electrodes modified with poly(4-aminophenol) and incorporating a specific oligonucleotide probe. The modified electrode containing the probe was evaluated by differential pulse voltammetry, before and after incubation with the complementary oligonucleotide target. Detection was performed by monitoring oxidizable DNA bases (direct detection) or using ethidium bromide as indicator of the hybridization process (indirect detection). The device showed a detection limit for the oligonucleotide target of 2.61 nmol L{sup −1}. Indirect detection using ethidium bromide was promising in discriminating mismatches, which is a very desirable attribute for detection of disease-related point mutations. In addition, it was possible to observe differences between hybridized and non-hybridized surfaces by atomic force microscopy.

  19. Preparation of genosensor for detection of specific DNA sequence of the hepatitis B virus

    Science.gov (United States)

    Honorato Castro, Ana C.; França, Erick G.; de Paula, Lucas F.; Soares, Marcia M. C. N.; Goulart, Luiz R.; Madurro, João M.; Brito-Madurro, Ana G.

    2014-09-01

    An electrochemical genosensor was constructed for detection of specific DNA sequence of the hepatitis B virus, based on graphite electrodes modified with poly(4-aminophenol) and incorporating a specific oligonucleotide probe. The modified electrode containing the probe was evaluated by differential pulse voltammetry, before and after incubation with the complementary oligonucleotide target. Detection was performed by monitoring oxidizable DNA bases (direct detection) or using ethidium bromide as indicator of the hybridization process (indirect detection). The device showed a detection limit for the oligonucleotide target of 2.61 nmol L-1. Indirect detection using ethidium bromide was promising in discriminating mismatches, which is a very desirable attribute for detection of disease-related point mutations. In addition, it was possible to observe differences between hybridized and non-hybridized surfaces by atomic force microscopy.

  20. Chimeric antigen receptor (CAR-specific monoclonal antibody to detect CD19-specific T cells in clinical trials.

    Directory of Open Access Journals (Sweden)

    Bipulendu Jena

    Full Text Available Clinical trials targeting CD19 on B-cell malignancies are underway with encouraging anti-tumor responses. Most infuse T cells genetically modified to express a chimeric antigen receptor (CAR with specificity derived from the scFv region of a CD19-specific mouse monoclonal antibody (mAb, clone FMC63. We describe a novel anti-idiotype monoclonal antibody (mAb to detect CD19-specific CAR(+ T cells before and after their adoptive transfer. This mouse mAb was generated by immunizing with a cellular vaccine expressing the antigen-recognition domain of FMC63. The specificity of the mAb (clone no. 136.20.1 was confined to the scFv region of the CAR as validated by inhibiting CAR-dependent lysis of CD19(+ tumor targets. This clone can be used to detect CD19-specific CAR(+ T cells in peripheral blood mononuclear cells at a sensitivity of 1∶1,000. In clinical settings the mAb is used to inform on the immunophenotype and persistence of administered CD19-specific T cells. Thus, our CD19-specific CAR mAb (clone no. 136.20.1 will be useful to investigators implementing CD19-specific CAR(+ T cells to treat B-lineage malignancies. The methodology described to develop a CAR-specific anti-idiotypic mAb could be extended to other gene therapy trials targeting different tumor associated antigens in the context of CAR-based adoptive T-cell therapy.

  1. Objective measures for detecting the auditory brainstem response: comparisons of specificity, sensitivity and detection time

    DEFF Research Database (Denmark)

    Chesnaye, M. A.; Bell, S. L.; Harte, J. M.

    2018-01-01

    of the Hotelling's T-2 test (applied in either time or frequency domain), two versions of the modified q-sample uniform scores test and both the Fsp and Fmp, which were evaluated using both conventional F-distributions with assumed degrees of freedom and a bootstrap approach. Study sample: Data consisted of click......-level when evaluating statistical significance using the bootstrap approach, as opposed to using conventional F-distributions. The FPRs of the remaining methods were slightly higher than expected. Conclusions: In this work, Hotelling's T-2 outperformed the alternative methods for automatically detecting ABRs......-evoked ABRs and recordings of EEG background activity from 12 to 17 normal hearing adults, respectively. Results: An overall advantage in sensitivity and detection time was demonstrated for the Hotelling's T-2 test. The false-positive rates (FPRs) of the Fsp and Fmp were also closer to the nominal alpha...

  2. Development of specific primers for the detection of HVA1 from ...

    African Journals Online (AJOL)

    African Journal of Biotechnology ... Detection methods are usually based on amplification of the target transgene. ... Since there exist a high homology between the barley HVA1 gene and the wheat gene, development of a specific sets of ...

  3. Technical specifications manual for the MARK-1 pulsed ionizing radiation detection system

    International Nuclear Information System (INIS)

    Lawrence, R.S.; Harker, Y.D.; Jones, J.L.; Hoggan, J.M.

    1993-03-01

    The MARK-1 detection system was developed by the Idaho National Engineering Laboratory for the US Department of Energy Office of Arms Control and Nonproliferation. The completely portable system was designed for the detection and analysis of intense photon emissions from pulsed ionizing radiation sources. This manual presents the technical design specifications for the MARK-1 detection system and was written primarily to assist the support or service technician in the service, calibration, and repair of the system. The manual presents the general detection system theory, the MARK-1 component design specifications, the acquisition and control software, the data processing sequence, and the system calibration procedure. A second manual entitled: Volume 2: Operations Manual for the MARK-1 Pulsed Ionizing Radiation Detection System (USDOE Report WINCO-1108, September 1992) provides a general operational description of the MARK-1 detection system. The Operations Manual was written primarily to assist the field operator in system operations and analysis of the data

  4. Technical specifications manual for the MARK-1 pulsed ionizing radiation detection system. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, R.S.; Harker, Y.D.; Jones, J.L.; Hoggan, J.M.

    1993-03-01

    The MARK-1 detection system was developed by the Idaho National Engineering Laboratory for the US Department of Energy Office of Arms Control and Nonproliferation. The completely portable system was designed for the detection and analysis of intense photon emissions from pulsed ionizing radiation sources. This manual presents the technical design specifications for the MARK-1 detection system and was written primarily to assist the support or service technician in the service, calibration, and repair of the system. The manual presents the general detection system theory, the MARK-1 component design specifications, the acquisition and control software, the data processing sequence, and the system calibration procedure. A second manual entitled: Volume 2: Operations Manual for the MARK-1 Pulsed Ionizing Radiation Detection System (USDOE Report WINCO-1108, September 1992) provides a general operational description of the MARK-1 detection system. The Operations Manual was written primarily to assist the field operator in system operations and analysis of the data.

  5. Shape anisotropy enhanced optomagnetic measurement for prostate-specific antigen detection via magnetic chain formation

    DEFF Research Database (Denmark)

    Tian, Bo; Wetterskog, Erik; Qiu, Zhen

    2017-01-01

    anisotropy), and directly increasing the optomagnetic signal (via optical shape anisotropy). We achieve a limit of detection (LOD) of 5.5 pM (0.82 ng/mL) for the detection of a model multivalent molecule, biotinylated anti-streptavidin, in PBS. For the measurements of prostate-specific antigen (PSA) in 50...

  6. Flow-based detection of IPv6-specific network layer attacks

    NARCIS (Netherlands)

    Hendriks, Luuk; Velan, Petr; de O. Schmidt, Ricardo; de Boer, Pieter-Tjerk; Pras, Aiko; Tuncer, Daphne; Koch, Robert; Badonne, Rémi; Stiller, Burkhard

    2017-01-01

    With a vastly different header format, IPv6 introduces new vulnerabilities not possible in IPv4, potentially requiring new detection algorithms. While many attacks specific to IPv6 have proven to be possible and are described in the literature, no detection solutions for these attacks have been

  7. Impedance-Based Miniaturized Biosensor for Ultrasensitive and Fast Prostate-Specific Antigen Detection

    Directory of Open Access Journals (Sweden)

    Ganna Chornokur

    2011-01-01

    Full Text Available This paper reports the successful fabrication of an impedance-based miniaturized biosensor and its application for ultrasensitive Prostate-Specific Antigen (PSA detection in standard and real human plasma solution, spiked with different PSA concentrations. The sensor was fabricated using photolithographic techniques, while monoclonal antibodies specific to human PSA were used as primary capture antibodies. Electrochemical impedance spectroscopy (EIS was employed as a detection technique. The sensor exhibited a detection limit of 1 pg/ml for PSA with minimal nonspecific binding (NSB. This detection limit is an order of magnitude lower than commercial PSA ELISA assays available on the market. The sensor can be easily modified into an array for the detection of other biomolecules of interest, enabling accurate, ultrasensitive, and inexpensive point-of-care sensing technologies.

  8. Specific PCR-based detection of Alternaria helianthi

    DEFF Research Database (Denmark)

    Udayashankar, A.C.; Nayaka, S. Chandra; Archana, B.

    2012-01-01

    Alternaria helianthi is an important seed-borne pathogenic fungus responsible for blight disease in sunflower. The current detection methods, which are based on culture and morphological identification, are time-consuming, laborious and are not always reliable. A PCR-based diagnostic method...... tested. The detection limit of the PCR method was of 10 pg from template DNA. The primers could also detect the pathogen in infected sunflower seed. This species-specific PCR method provides a quick, simple, powerful and reliable alternative to conventional methods in the detection and identification...

  9. The detection and specifity of class specific antibodies to whole bacteria cells using a solid phase radioimmunoassay

    International Nuclear Information System (INIS)

    Czerkinsky, C.; Rees, A.S.; Bergimeier, L.A.; Challacombe, S.J.

    1983-01-01

    A solid phase radioimmunoassay has been developed which can be used for the detection of isotype specific antibodies to whole bacteria and other particulate antigens, and is applicable to a variety of species. Bacteria are bound to the solid phase by the use either of antibodies, or of methyl glyoxal. Both methods result in a sensitive and reproducible assay, and bacteria do not appear to desorb from the solid phase. The specificity of antibodies to whole bacteria was examined by absorption of antisera with various species of bacteria and retesting, or by determining the binding of antisera to various bacteria bound to the solid phase. Both methods revealed specificity for the bacteria examined. Inhibition studies showed that antibodies to Streptococcus mutans whole cells could be inhibited by purified cell surface antigens glucosyltransferase and antigen I/II, but only minimally by lipoteichoic acid, c polysaccharide or dextran. In murine antisera antibodies of the IgG, IgM, and IgA classes could be detected at amounts of less than 1 ng/ml. (author)

  10. New concepts of fluorescent probes for specific detection of DNA sequences: bis-modified oligonucleotides in excimer and exciplex detection.

    Science.gov (United States)

    Gbaj, A; Bichenkova, Ev; Walsh, L; Savage, He; Sardarian, Ar; Etchells, Ll; Gulati, A; Hawisa, S; Douglas, Kt

    2009-12-01

    The detection of single base mismatches in DNA is important for diagnostics, treatment of genetic diseases, and identification of single nucleotide polymorphisms. Highly sensitive, specific assays are needed to investigate genetic samples from patients. The use of a simple fluorescent nucleoside analogue in detection of DNA sequence and point mutations by hybridisation in solution is described in this study. The 5'-bispyrene and 3'-naphthalene oligonucleotide probes form an exciplex on hybridisation to target in water and the 5'-bispyrene oligonucleotide alone is an adequate probe to determine concentration of target present. It was also indicated that this system has a potential to identify mismatches and insertions. The aim of this work was to investigate experimental structures and conditions that permit strong exciplex emission for nucleic acid detectors, and show how such exciplexes can register the presence of mismatches as required in SNP analysis. This study revealed that the hybridisation of 5'-bispyrenyl fluorophore to a DNA target results in formation of a fluorescent probe with high signal intensity change and specificity for detecting a complementary target in a homogeneous system. Detection of SNP mutations using this split-probe system is a highly specific, simple, and accessible method to meet the rigorous requirements of pharmacogenomic studies. Thus, it is possible for the system to act as SNP detectors and it shows promise for future applications in genetic testing.

  11. Radioimmunoassay for the detection of virus-specific IgA antibodies in saliva

    International Nuclear Information System (INIS)

    Friedman, M.G.

    1982-01-01

    The use of a sensitive and versatile radioimmunoassay (RIA) for detection of mumps-specific IgA and measles-specific IgA in unconcentrated saliva samples is described. The samples were obtained either by expectoration or by swabbing of the oral cavity, with or without stimulation of secretion, and were inactivated and clarified before testing. Mumps-specific IgA antibodies were detected as early as one day after onset of illness and peaked at 1-2 weeks after onset. Measles-specific salivary IgA antibodies were detected in 15-month old children 2-3 weeks after immunization. These results suggest that the RIA technique may be useful for early diagnosis of viral infections and for confirmation of response to immunization without the need for a blood sample, as well as for the study of the secretory immune response in very young and older subjects. (Auth.)

  12. An Energy efficient application specific integrated circuit for electrocardiogram feature detection and its potential for ambulatory cardiovascular disease detection.

    Science.gov (United States)

    Jain, Sanjeev Kumar; Bhaumik, Basabi

    2016-03-01

    A novel algorithm based on forward search is developed for real-time electrocardiogram (ECG) signal processing and implemented in application specific integrated circuit (ASIC) for QRS complex related cardiovascular disease diagnosis. The authors have evaluated their algorithm using MIT-BIH database and achieve sensitivity of 99.86% and specificity of 99.93% for QRS complex peak detection. In this Letter, Physionet PTB diagnostic ECG database is used for QRS complex related disease detection. An ASIC for cardiovascular disease detection is fabricated using 130-nm CMOS high-speed process technology. The area of the ASIC is 0.5 mm(2). The power dissipation is 1.73 μW at the operating frequency of 1 kHz with a supply voltage of 0.6 V. The output from the ASIC is fed to their Android application that generates diagnostic report and can be sent to a cardiologist through email. Their ASIC result shows average failed detection rate of 0.16% for six leads data of 290 patients in PTB diagnostic ECG database. They also have implemented a low-leakage version of their ASIC. The ASIC dissipates only 45 pJ with a supply voltage of 0.9 V. Their proposed ASIC is most suitable for energy efficient telemetry cardiovascular disease detection system.

  13. A novel SERRS sandwich-hybridization assay to detect specific DNA target.

    Directory of Open Access Journals (Sweden)

    Cécile Feuillie

    Full Text Available In this study, we have applied Surface Enhanced Resonance Raman Scattering (SERRS technology to the specific detection of DNA. We present an innovative SERRS sandwich-hybridization assay that allows specific DNA detection without any enzymatic amplification, such as is the case with Polymerase Chain Reaction (PCR. In some substrates, such as ancient or processed remains, enzymatic amplification fails due to DNA alteration (degradation, chemical modification or to the presence of inhibitors. Consequently, the development of a non-enzymatic method, allowing specific DNA detection, could avoid long, expensive and inconclusive amplification trials. Here, we report the proof of concept of a SERRS sandwich-hybridization assay that leads to the detection of a specific chamois DNA. This SERRS assay reveals its potential as a non-enzymatic alternative technology to DNA amplification methods (particularly the PCR method with several applications for species detection. As the amount and type of damage highly depend on the preservation conditions, the present SERRS assay would enlarge the range of samples suitable for DNA analysis and ultimately would provide exciting new opportunities for the investigation of ancient DNA in the fields of evolutionary biology and molecular ecology, and of altered DNA in food frauds detection and forensics.

  14. Rapid and specific detection of Asian- and African-lineage Zika viruses

    Science.gov (United States)

    Chotiwan, Nunya; Brewster, Connie D.; Magalhaes, Tereza; Weger-Lucarelli, James; Duggal, Nisha K.; Rückert, Claudia; Nguyen, Chilinh; Garcia Luna, Selene M.; Fauver, Joseph R.; Andre, Barb; Gray, Meg; Black, William C.; Kading, Rebekah C.; Ebel, Gregory D.; Kuan, Guillermina; Balmaseda, Angel; Jaenisch, Thomas; Marques, Ernesto T. A.; Brault, Aaron C.; Harris, Eva; Foy, Brian D.; Quackenbush, Sandra L.; Perera, Rushika; Rovnak, Joel

    2017-01-01

    Understanding the dynamics of Zika virus transmission and formulating rational strategies for its control require precise diagnostic tools that are also appropriate for resource-poor environments. We have developed a rapid and sensitive loop-mediated isothermal amplification (LAMP) assay that distinguishes Zika viruses of Asian and African lineages. The assay does not detect chikungunya virus or flaviviruses such as dengue, yellow fever, or West Nile viruses. The assay conditions allowed direct detection of Zika virus RNA in cultured infected cells; in mosquitoes; in virus-spiked samples of human blood, plasma, saliva, urine, and semen; and in infected patient serum, plasma, and semen samples without the need for RNA isolation or reverse transcription. The assay offers rapid, specific, sensitive, and inexpensive detection of the Asian-lineage Zika virus strain that is currently circulating in the Western hemisphere, and can also detect the African-lineage Zika virus strain using separate, specific primers. PMID:28469032

  15. New Concepts of Fluorescent Probes for Specific Detection of DNA Sequences: Bis-Modified Oligonucleotides in Excimer and Exciplex Detection

    Directory of Open Access Journals (Sweden)

    Gbaj A

    2009-01-01

    Full Text Available The detection of single base mismatches in DNA is important for diagnostics, treatment of genetic diseases, and identification of single nucleotide polymorphisms. Highly sensitive, specific assays are needed to investigate genetic samples from patients. The use of a simple fluorescent nucleoside analogue in detection of DNA sequence and point mutations by hybridisation in solution is described in this study. The 5’-bispyrene and 3’-naphthalene oligonucleotide probes form an exciplex on hybridisation to target in water and the 5’-bispyrene oligonucleotide alone is an adequate probe to determine concentration of target present. It was also indicated that this system has a potential to identify mismatches and insertions. The aim of this work was to investigate experimental structures and conditions that permit strong exciplex emission for nucleic acid detectors, and show how such exciplexes can register the presence of mismatches as required in SNP analysis. This study revealed that the hybridisation of 5'-bispyrenyl fluorophore to a DNA target results in formation of a fluorescent probe with high signal intensity change and specificity for detecting a complementary target in a homogeneous system. Detection of SNP mutations using this split-probe system is a highly specific, simple, and accessible method to meet the rigorous requirements of pharmacogenomic studies. Thus, it is possible for the system to act as SNP detectors and it shows promise for future applications in genetic testing.

  16. Species-specific optical genosensors for the detection of mycotoxigenic Fusarium fungi in food samples

    International Nuclear Information System (INIS)

    Peltomaa, Riikka; Vaghini, Silvia; Patiño, Belén; Benito-Peña, Elena; Moreno-Bondi, María C.

    2016-01-01

    Plant-pathogenic Fusarium species, Fusarium verticillioides and Fusarium proliferatum, are the major producers of fumonisins which are one of the most common mycotoxins found in maize. Herein, we report the development of specific and sensitive genosensors for detecting these two closely related Fusarium species in food samples. The sensors are based on species-specific capture and detection probes, which bind to the intergenic spacer region of rDNA (IGS). Oligonucleotide functionalized magnetic microbeads are used to capture the target DNA which is then detected using biotinylated detection probes and a streptavidin-coupled label. The developed genosensors had detection limits of 1.8 pM and 3.0 pM for F. proliferatum and F. verticillioides, respectively, using synthetic DNA targets. Furthermore, the biosensors were used to analyze natural fungal contamination of commercial maize samples. After amplification of the genomic DNA the sensors detected the presence of the fungi, in accordance with previous results obtained with PCR. No cross-reactivity between F. verticillioides and F. proliferatum, or other fungi species tested, was observed. The developed biosensors can provide a valuable tool to evaluate the potential for mycotoxin contamination in conditions where detection of mycotoxins directly is challenging. - Highlights: • Optical genosensors detect fumonisin producing Fusarium species in maize samples. • Oligonucleotide probes designed on the intergenic spacer region of rDNA can distinguish between closely related species. • Sandwich hybridization assay with magnetic microbeads allows species-specific detection of Fusarium spp. directly from PCR.

  17. Species-specific optical genosensors for the detection of mycotoxigenic Fusarium fungi in food samples

    Energy Technology Data Exchange (ETDEWEB)

    Peltomaa, Riikka; Vaghini, Silvia [Department of Analytical Chemistry, Faculty of Chemistry, Complutense University, Ciudad Universitaria s/n, Madrid 28040 (Spain); Patiño, Belén [Department of Microbiology III, Faculty of Biology, Complutense University, Ciudad Universitaria s/n, Madrid 28040 (Spain); Benito-Peña, Elena, E-mail: elenabp@ucm.es [Department of Analytical Chemistry, Faculty of Chemistry, Complutense University, Ciudad Universitaria s/n, Madrid 28040 (Spain); Moreno-Bondi, María C., E-mail: mcmbondi@ucm.es [Department of Analytical Chemistry, Faculty of Chemistry, Complutense University, Ciudad Universitaria s/n, Madrid 28040 (Spain)

    2016-09-07

    Plant-pathogenic Fusarium species, Fusarium verticillioides and Fusarium proliferatum, are the major producers of fumonisins which are one of the most common mycotoxins found in maize. Herein, we report the development of specific and sensitive genosensors for detecting these two closely related Fusarium species in food samples. The sensors are based on species-specific capture and detection probes, which bind to the intergenic spacer region of rDNA (IGS). Oligonucleotide functionalized magnetic microbeads are used to capture the target DNA which is then detected using biotinylated detection probes and a streptavidin-coupled label. The developed genosensors had detection limits of 1.8 pM and 3.0 pM for F. proliferatum and F. verticillioides, respectively, using synthetic DNA targets. Furthermore, the biosensors were used to analyze natural fungal contamination of commercial maize samples. After amplification of the genomic DNA the sensors detected the presence of the fungi, in accordance with previous results obtained with PCR. No cross-reactivity between F. verticillioides and F. proliferatum, or other fungi species tested, was observed. The developed biosensors can provide a valuable tool to evaluate the potential for mycotoxin contamination in conditions where detection of mycotoxins directly is challenging. - Highlights: • Optical genosensors detect fumonisin producing Fusarium species in maize samples. • Oligonucleotide probes designed on the intergenic spacer region of rDNA can distinguish between closely related species. • Sandwich hybridization assay with magnetic microbeads allows species-specific detection of Fusarium spp. directly from PCR.

  18. Subnanomole detection and quantitation of high specific activity 32P-nucleotides

    International Nuclear Information System (INIS)

    Coniglio, C.; Pappas, G.; Gill, W.J.; Kashdan, M.; Maniscalco, M.

    1991-01-01

    Microbore liquid chromatography utilizes conventional HPLC and ultraviolet detection principles to determine subnanomole mass quantities of biologically significant molecules. This system takes advantage of specifically designed microflow equipment to analyze ultraviolet absorbing species at the picomole range. 32P-labeled nucleotides are examples of compounds routinely used at picomole quantities that are extremely difficult to accurately quantify using standard mass measurement techniques. The procedure described in this paper has the capability of measuring nucleotides down to 10 pmol using commercially available microbore ultraviolet detection equipment. The technique can be used to accurately measure the specific activity of as little as 10 microCi of an aqueous 32P-nucleotide solution

  19. Screening DNA chip and event-specific multiplex PCR detection methods for biotech crops.

    Science.gov (United States)

    Lee, Seong-Hun

    2014-11-01

    There are about 80 biotech crop events that have been approved by safety assessment in Korea. They have been controlled by genetically modified organism (GMO) and living modified organism (LMO) labeling systems. The DNA-based detection method has been used as an efficient scientific management tool. Recently, the multiplex polymerase chain reaction (PCR) and DNA chip have been developed as simultaneous detection methods for several biotech crops' events. The event-specific multiplex PCR method was developed to detect five biotech maize events: MIR604, Event 3272, LY 038, MON 88017 and DAS-59122-7. The specificity was confirmed and the sensitivity was 0.5%. The screening DNA chip was developed from four endogenous genes of soybean, maize, cotton and canola respectively along with two regulatory elements and seven genes: P35S, tNOS, pat, bar, epsps1, epsps2, pmi, cry1Ac and cry3B. The specificity was confirmed and the sensitivity was 0.5% for four crops' 12 events: one soybean, six maize, three cotton and two canola events. The multiplex PCR and DNA chip can be available for screening, gene-specific and event-specific analysis of biotech crops as efficient detection methods by saving on workload and time. © 2014 Society of Chemical Industry. © 2014 Society of Chemical Industry.

  20. Radioimmunoassay for detection of VP1 specific neutralizing antibodies of foot and mouse disease virus

    International Nuclear Information System (INIS)

    Patzer, E.J.; Jackson, M.L.; Moore, D.M.

    1985-01-01

    A solid-phase radioimmunoassay was developed for the detection of antibodies against a specific region of the VP1 protein of the A24 and O1 serotypes of foot and mouth disease virus. The antibody titers from the radioimmunoassay showed a positive correlation with neutralizing antibody titers determined by a mouse protection assay. The specificity of the assay resides in the peptide used as antigen. The assay is rapid, reproducible and does not require the use of whole virions. (orig.)

  1. Barium enema and endoscopy for the detection of colorectal neoplasia: Sensitivity, specificity, complications and its determinants

    International Nuclear Information System (INIS)

    Zwart, Ingrid M. de; Griffioen, Gerrit; Shaw, M. Pertaap Chandie; Lamers, Cornelis B.H.W.; Roos, Albert de

    2001-01-01

    AIM: To analyse sensitivity, specificity and complication rate of endoscopy, and barium enema for the detection of colorectal neoplasia. MATERIALS AND METHODS: A MEDLINE search was performed (1980-2000) directed at the endoscopic and radiologic literature on barium enema. Articles were selected based on the type of study, availability of sensitivity and specificity values in sizeable patient groups, and reports on complications. Sixty articles were included in the analysis. RESULTS: Endoscopy proved to have superior sensitivity for polyps in patients at high-risk for colorectal neoplasia. The role of endoscopy and radiology in average-risk screening populations is not known. Sensitivity and specificity rates ranged widely, probably due to bias. For the detection of small polyps endoscopy has superior performance, whereas sensitivity is similar for endoscopy and barium enema for the detection of larger (>1 cm) polyps and tumours. Overall, endoscopy is associated with a higher complication rate. CONCLUSION: Endoscopy is the preferred detection method in high-risk patients. The role of endoscopy and radiology in a screening setting requires evaluation. This review provides the test characteristics of endoscopy and radiology which are relevant for a cost-effectiveness analysis. Double-contrast barium enema may play an important role for screening purposes, owing to its good sensitivity for detecting larger (>1 cm) polyps and its lack of major complications. Zwart, I.M. de et al. (2001)

  2. Epitope specificity determines pathogenicity and detectability in ANCA-associated vasculitis

    Science.gov (United States)

    ABSTRACT BACKGROUND Anti-neutrophil cytoplasmic autoantibodies (ANCA) specific for myeloperoxidase (MPO) or proteinase 3 (PR3) are detectable in >90% of patients with ANCA-associated vasculitis (AAV). ANCA titers do not correlate well with disease activity. In vivo and in vi...

  3. Development of an Enzyme Linked Immunosorbent Assay to Detect Chicken Parvovirus Specific Antibodies

    Science.gov (United States)

    Here we report the development and application of an enzyme linked immunosorbent assay to detect parvovirus-specific antibodies in chicken sera. We used an approach previously described for other parvoviruses to clone and express viral structural proteins in insect cells from recombinant baculovirus...

  4. Taxon-specific PCR primers to detect two inconspicuous arbuscular mycorrhizal fungi from temperate agricultural grassland

    NARCIS (Netherlands)

    Gamper, H.A.; Leuchtmann, A.

    2007-01-01

    Taxon-specific polymerase chain reaction (PCR) primers enable detection of arbuscular mycorrhizal fungi (AMF, Glomeromycota) in plant roots where the fungi lack discriminative morphological and biochemical characters. We designed and validated pairs of new PCR primers targeted to the flanking

  5. Development of a dipstick assay for detection of Leishmania-specific canine antibodies

    NARCIS (Netherlands)

    Schallig, Henk D. F. H.; Cardoso, Luís; Hommers, Marieke; Kroon, Nel; Belling, Guus; Rodrigues, Manuela; Semião-Santos, Saul J.; Vetter, Hans

    2004-01-01

    A dipstick assay, based on Leishmania infantum antigen, for the rapid detection of Leishmania-specific antibodies in canine serum samples was developed and evaluated. After determination of optimal dipstick test conditions, test performance was compared with two existing serological tests, i.e., the

  6. Evaluation of six immunoassays for detection of dengue virus-specific immunoglobulin M and G antibodies

    NARCIS (Netherlands)

    J. Groen (Jan); P. Koraka (Penelope); J. Velzing (Jans); C. Copra (Cederick); A.D.M.E. Osterhaus (Albert)

    2000-01-01

    textabstractThe performance of six commercially available immunoassay systems for the detection of dengue virus-specific immunoglobulin M (IgM) and IgG antibodies in serum was evaluated. These included two IgM and IgG enzyme immunoassays (EIA) from MRL Laboratories and PanBio, a rapid

  7. Specific and selective target detection of supra-genome 21 Mers Salmonella via silicon nanowires biosensor

    Science.gov (United States)

    Mustafa, Mohammad Razif Bin; Dhahi, Th S.; Ehfaed, Nuri. A. K. H.; Adam, Tijjani; Hashim, U.; Azizah, N.; Mohammed, Mohammed; Noriman, N. Z.

    2017-09-01

    The nano structure based on silicon can be surface modified to be used as label-free biosensors that allow real-time measurements. The silicon nanowire surface was functionalized using 3-aminopropyltrimethoxysilane (APTES), which functions as a facilitator to immobilize biomolecules on the silicon nanowire surface. The process is simple, economical; this will pave the way for point-of-care applications. However, the surface modification and subsequent detection mechanism still not clear. Thus, study proposed step by step process of silicon nano surface modification and its possible in specific and selective target detection of Supra-genome 21 Mers Salmonella. The device captured the molecule with precisely; the approach took the advantages of strong binding chemistry created between APTES and biomolecule. The results indicated how modifications of the nanowires provide sensing capability with strong surface chemistries that can lead to specific and selective target detection.

  8. Species-specific audio detection: a comparison of three template-based detection algorithms using random forests

    Directory of Open Access Journals (Sweden)

    Carlos J. Corrada Bravo

    2017-04-01

    Full Text Available We developed a web-based cloud-hosted system that allow users to archive, listen, visualize, and annotate recordings. The system also provides tools to convert these annotations into datasets that can be used to train a computer to detect the presence or absence of a species. The algorithm used by the system was selected after comparing the accuracy and efficiency of three variants of a template-based detection. The algorithm computes a similarity vector by comparing a template of a species call with time increments across the spectrogram. Statistical features are extracted from this vector and used as input for a Random Forest classifier that predicts presence or absence of the species in the recording. The fastest algorithm variant had the highest average accuracy and specificity; therefore, it was implemented in the ARBIMON web-based system.

  9. [A novel TaqMan® MGB probe for specifically detecting Streptococcus mutans].

    Science.gov (United States)

    Zheng, Hui; Lin, Jiu-Xiang; DU, Ning; Chen, Feng

    2013-10-18

    To design a new TaqMan® MGB probe for improving the specificity of Streptococcus mutans's detection. We extracted six DNA samples from different streptococcal strains for PCR reaction. Conventional nested PCR and TaqMan® MGB real-time PCR were applied independently. The first round of nested PCR was carried out with the bacterial universal primers, while a second PCR was conducted by using primers specific for the 16S rRNA gene of Streptococcus mutans. The TaqMan® MGB probe for Streptococcus mutans was designed from sequence analyses, and the primers were the same as nested PCR. Streptococcus mutans DNA with 2.5 mg/L was sequentially diluted at 5-fold intervals to 0.16 μg/L. Standard DNA samples were used to generate standard curves by TaqMan® MGB real-time PCR. In the nested PCR, the primers specific for Streptococcus mutans also detected Streptococcus gordonii with visible band of 282 bp, giving false-positive results. In the TaqMan® MGB real-time PCR reaction, only Streptococcus mutans was detected. The detection limitation of TaqMan® MGB real-time PCR for Streptococcus mutans 16S rRNA gene was 20 μg/L. We designed a new TaqMan® MGB probe, and successfully set up a PCR based method for detecting oral Streptococcus mutans. TaqMan® MGB real-time PCR is a both specific and sensitive bacterial detection method.

  10. Indirect micro-immunofluorescence test for detecting type-specific antibodies to herpes simplex virus.

    Science.gov (United States)

    Forsey, T; Darougar, S

    1980-02-01

    A rapid indirect micro-immunofluorescence test capable of detecting and differentiating type-specific antibodies to herpes simplex virus is described. The test proved highly sensitive and, in 80 patients with active herpes ocular infection, antibody was detected in 94%. No anti-herpes antibody was detected in a control group of 20 patients with adenovirus infections. Testing of animal sera prepared against herpes simplex virus types 1 and 2 and of human sera from cases of ocular and genital herpes infections showed that the test can differentiate antibodies to the infecting serotypes. Specimens of whole blood, taken by fingerprick, and eye secretions, both collected on cellulose sponges, could be tested by indirect micro-immunofluorescence. Anti-herpes IgG, IgM, and IgA can also be detected.

  11. Highly specific detection of genetic modification events using an enzyme-linked probe hybridization chip.

    Science.gov (United States)

    Zhang, M Z; Zhang, X F; Chen, X M; Chen, X; Wu, S; Xu, L L

    2015-08-10

    The enzyme-linked probe hybridization chip utilizes a method based on ligase-hybridizing probe chip technology, with the principle of using thio-primers for protection against enzyme digestion, and using lambda DNA exonuclease to cut multiple PCR products obtained from the sample being tested into single-strand chains for hybridization. The 5'-end amino-labeled probe was fixed onto the aldehyde chip, and hybridized with the single-stranded PCR product, followed by addition of a fluorescent-modified probe that was then enzymatically linked with the adjacent, substrate-bound probe in order to achieve highly specific, parallel, and high-throughput detection. Specificity and sensitivity testing demonstrated that enzyme-linked probe hybridization technology could be applied to the specific detection of eight genetic modification events at the same time, with a sensitivity reaching 0.1% and the achievement of accurate, efficient, and stable results.

  12. Hybrid Synthetic Receptors on MOSFET Devices for Detection of Prostate Specific Antigen in Human Plasma.

    Science.gov (United States)

    Tamboli, Vibha K; Bhalla, Nikhil; Jolly, Pawan; Bowen, Chris R; Taylor, John T; Bowen, Jenna L; Allender, Chris J; Estrela, Pedro

    2016-12-06

    The study reports the use of extended gate field-effect transistors (FET) for the label-free and sensitive detection of prostate cancer (PCa) biomarkers in human plasma. The approach integrates for the first time hybrid synthetic receptors comprising of highly selective aptamer-lined pockets (apta-MIP) with FETs for sensitive detection of prostate specific antigen (PSA) at clinically relevant concentrations. The hybrid synthetic receptors were constructed by immobilizing an aptamer-PSA complex on gold and subjecting it to 13 cycles of dopamine electropolymerization. The polymerization resulted in the creation of highly selective polymeric cavities that retained the ability to recognize PSA post removal of the protein. The hybrid synthetic receptors were subsequently used in an extended gate FET setup for electrochemical detection of PSA. The sensor was reported to have a limit of detection of 0.1 pg/mL with a linear detection range from 0.1 pg/mL to 1 ng/mL PSA. Detection of 1-10 pg/mL PSA was also achieved in diluted human plasma. The present apta-MIP sensor developed in conjunction with FET devices demonstrates the potential for clinical application of synthetic hybrid receptors for the detection of clinically relevant biomarkers in complex samples.

  13. Patient-Specific Circulating Tumor DNA Detection during Neoadjuvant Chemotherapy in Triple-Negative Breast Cancer.

    Science.gov (United States)

    Riva, Francesca; Bidard, Francois-Clement; Houy, Alexandre; Saliou, Adrien; Madic, Jordan; Rampanou, Aurore; Hego, Caroline; Milder, Maud; Cottu, Paul; Sablin, Marie-Paule; Vincent-Salomon, Anne; Lantz, Olivier; Stern, Marc-Henri; Proudhon, Charlotte; Pierga, Jean-Yves

    2017-03-01

    In nonmetastatic triple-negative breast cancer (TNBC) patients, we investigated whether circulating tumor DNA (ctDNA) detection can reflect the tumor response to neoadjuvant chemotherapy (NCT) and detect minimal residual disease after surgery. Ten milliliters of plasma were collected at 4 time points: before NCT; after 1 cycle; before surgery; after surgery. Customized droplet digital PCR (ddPCR) assays were used to track tumor protein p53 ( TP53 ) mutations previously characterized in tumor tissue by massively parallel sequencing (MPS). Forty-six patients with nonmetastatic TNBC were enrolled. TP53 mutations were identified in 40 of them. Customized ddPCR probes were validated for 38 patients, with excellent correlation with MPS ( r = 0.99), specificity (≥2 droplets/assay), and sensitivity (at least 0.1%). At baseline, ctDNA was detected in 27/36 patients (75%). Its detection was associated with mitotic index ( P = 0.003), tumor grade ( P = 0.003), and stage ( P = 0.03). During treatment, we observed a drop of ctDNA levels in all patients but 1. No patient had detectable ctDNA after surgery. The patient with rising ctDNA levels experienced tumor progression during NCT. Pathological complete response (16/38 patients) was not correlated with ctDNA detection at any time point. ctDNA positivity after 1 cycle of NCT was correlated with shorter disease-free ( P < 0.001) and overall ( P = 0.006) survival. Customized ctDNA detection by ddPCR achieved a 75% detection rate at baseline. During NCT, ctDNA levels decreased quickly and minimal residual disease was not detected after surgery. However, a slow decrease of ctDNA level during NCT was strongly associated with shorter survival. © 2016 American Association for Clinical Chemistry.

  14. Specific antibodies to detect Tamarillo leaf malformation virus (TALMV) in Tamarillo

    International Nuclear Information System (INIS)

    Gallo Garcia, Yuliana; Marin Montoya, Mauricio; Gutierrez, Pablo Andres

    2011-01-01

    In Colombia, yields of Tamarillo are seriously affected by a complex viral disease known as virosis. This pathology was first reported in 1991 in the north of Antioquia and currently affects all Tamarillo growing regions in the country. Recent works have demonstrated the association of two potyviruses (potyviridae) with this disease: potato virus y (PVY) and Tamarillo leaf malformation virus (TALMV, proposed species). Specific diagnostic tools are required for early asymptomatic detection of these viruses and Tamarillo certification programs. In this study, we report the obtention of TALMV specific antibodies using a 15 residues peptide mimicking the n-terminal coat protein. Specificity and sensitivity of the anti-TALMV antibodies was determined by Elisa and dot-blot using recombinant protein and synthetic peptides as controls. The usefulness of these antibodies was validated from a preliminary trial of TALMV detection in plant samples obtained from Tamarillo crops in eastern Antioquia and results were compared with a TALMV specific coat RT-PCR detection protocol.

  15. Synthetic oligonucleotide antigens modified with locked nucleic acids detect disease specific antibodies

    DEFF Research Database (Denmark)

    Samuelsen, Simone V; Solov'yov, Ilia A.; Balboni, Imelda M.

    2016-01-01

    New techniques to detect and quantify antibodies to nucleic acids would provide a significant advance over current methods, which often lack specificity. We investigate the potential of novel antigens containing locked nucleic acids (LNAs) as targets for antibodies. Particularly, employing...... molecular dynamics we predict optimal nucleotide composition for targeting DNA-binding antibodies. As a proof of concept, we address a problem of detecting anti-DNA antibodies that are characteristic of systemic lupus erythematosus, a chronic autoimmune disease with multiple manifestations. We test the best...... that the novel method is a promising tool to create antigens for research and point-of-care monitoring of anti-DNA antibodies....

  16. Specific dot-immunobinding assay for detection and enumeration of Thiobacillus ferrooxidans

    International Nuclear Information System (INIS)

    Arredondo, R.; Jerez, C.A.

    1989-01-01

    A specific and very sensitive dot-immunobinding assay for the detection and enumeration of the bioleaching microorganism Thiobacillus ferrooxidans was developed. Nitrocellulose spotted with samples was incubated with polyclonal antisera against whole T. ferrooxidans cells and then in 125 I-labeled protein A or 125 I-labeled goat antirabbit immunoglobulin G; incubation was followed by autoradiography. Since a minimum of 10 3 cells per dot could be detected, the method offers the possibility of simultaneous processing of numerous samples in a short time to monitor the levels of T. ferrooxidans in bioleaching operations

  17. Multimodal technique to eliminate humidity interference for specific detection of ethanol.

    Science.gov (United States)

    Jalal, Ahmed Hasnain; Umasankar, Yogeswaran; Gonzalez, Pablo J; Alfonso, Alejandro; Bhansali, Shekhar

    2017-01-15

    Multimodal electrochemical technique incorporating both open circuit potential (OCP) and amperometric techniques have been conceptualized and implemented to improve the detection of specific analyte in systems where more than one analyte is present. This approach has been demonstrated through the detection of ethanol while eliminating the contribution of water in a micro fuel cell sensor system. The sensor was interfaced with LMP91000 potentiostat, controlled through MSP430F5529LP microcontroller to implement an auto-calibration algorithm tailored to improve the detection of alcohol. The sensor was designed and fabricated as a three electrode system with Nafion as a proton exchange membrane (PEM). The electrochemical signal of the interfering phase (water) was eliminated by implementing the multimodal electrochemical detection technique. The results were validated by comparing sensor and potentiostat performances with a commercial sensor and potentiostat respectively. The results suggest that such a sensing system can detect ethanol at concentrations as low as 5ppm. The structure and properties such as low detection limit, selectivity and miniaturized size enables potential application of this device in wearable transdermal alcohol measurements. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Detection of pregnancy in sheep using an ELISA for pregnancy-specific protein B.

    Science.gov (United States)

    Milisits-Németh, Tímea; Balogh, Orsolya Gabriella; Egerszegi, István; Kern, László; Sasser, R Garth; Gábor, György

    2018-06-01

    The early detection of pregnancy and the determination of fetal numbers have economic benefits in sheep production because of the seasonal breeding patterns where missing a breeding opportunity means the loss of one productive year. The purpose of this study was to evaluate the efficacy of the B6-HRP ELISA for ovine pregnancy-specific protein B (oPSPB) measurement in the detection of pregnancy and estimation of fetal numbers in different sheep breeds. BioPRYN® ELISA assay kit was used for the detection of pregnancy in the experimental animals. Ninety-three ewes of three breeds (British Milksheep - BM, Lacaune - L and Transylvanian Racka - TR), each from three farms in Hungary, were included in the study. BM and L ewes were artificially inseminated (AI). Thirty-five days after AI, all ewes were examined by transabdominal ultrasound. The TR flock was mated naturally over a six-week period. At the end of the mating period, the ewes were similarly examined by ultrasound. Blood samples were taken from all pregnant ewes twice (35 and 65 days after AI), and serum samples were assayed by the BioPRYN test. It can be concluded that the detection of serum PSPB by ELISA is a much easier, safer, less expensive and highly accurate method for the detection of ovine pregnancy. Although some breed-related differences were detectable at 35 and 65 days post breeding, no differences in oPSPB levels were found in pregnant ewes carrying different numbers of fetuses.

  19. Device for detecting the specific gravity of a liquid. [Patent application

    Science.gov (United States)

    Derouin, C.R.; Kerwin, W.J.; McCormick, J.B.; Bobbett, R.E.

    1980-11-18

    A device for detecting the specific gravity of a liquid and a device for detecting the state of charge of a liquid phase electrolyte battery are described. In one embodiment of the present invention, a change in the critical angle of total internal reflection is utilized to determine the index of refraction of the liquid to be measured. It is shown that the index of refraction of the liquid is a function of the specific gravity of the liquid. In applications for measuring the state of charge of a battery, the specific gravity is proportional to the state of charge of the battery. A change in intensity of rays intersecting an interface surface indicates the critical angle which is a direct indication of the specific gravity of the liquid and the state of charge of a battery. In another embodiment, a light beam is projected through a transparent medium and then through a portion of the liquid to be measured. A change in refraction due to a change in the index of refraction of the liquid produces a deflection of the beam which is measured by a detector. The magnitude of deflection of the beam is directly proportional to the specific gravity of the liquid and the state of charge of a battery.

  20. Evaluation of the specificity of radionuclide myocardial imaging for detecting CAD

    International Nuclear Information System (INIS)

    Liu Xiujie

    1992-01-01

    In order to evaluate the specificity of radionuclide myocardial perfusion imaging for detecting coronary artery disease (CAD), 50 patients with normal coronary arteriography and radionuclide myocardial perfusion scintigraphy were analysed. The results from 201 T1 (20 cases) and 99m Tc-MIBI (30 cases) studies showed that out of 33 patients with no organic cardiovascular disease, 29 had normal myocardial imaging, and the specificity of radionuclide myocardial imaging for detecting CAD was 87.8%. 4 normal young women had false positive myocardial imaging. Out of 17 patients with cardiovascular disease and normal coronary arteriography, 15 patients had abnormal myocardial imaging. The final clinical diagnoses of these 15 patients were: 4 patients with hypertrophic cardiomyopathy, 3 with old myocardial infarction, 2 with myocarditis, 3 with small coronary vessel disease, 1 with congestive cardiomyopathy, and 2 with other cardiac disorder. The points of differentiation between CAD and other cardiovascular disease using radionuclide techniques were discussed

  1. [Immunochemical Detection of Azospirilla in Soil with Genus-Specific Antibodies].

    Science.gov (United States)

    Shirokov, A A; Krasov, A I; Selivanov, N Yu; Burygin, G L; Shchegolev, S Yu; Matora, L Yu

    2015-01-01

    Immunoelectrophoresis and immunodiffusion analysis with antibodies to whole intact cells of the type strain of nitrogen-fixing soil bacteria Azospirillum brasilense Sp7 revealed at least three conservative surface immunogenic proteins of azospirilla. Cross-reactions with these proteins made it possible to use the above antibodies for detection of azospirilla as a genus-specific probe conjugated with horseradish peroxidase as an enzymatic label. Direct immune-enzyme analysis of soil suspensions (typical chernozem, Saratov oblast) confirmed applicability of the conjugates based on genus-specific antibodies to the surface proteins of azospirilla for direct detection of this bacterial genus in environmental samples. These results provide a basis for broad application of this method for analysis of Azospirillum occurrence in soil.

  2. Detection of herpes simplex virus-specific DNA sequences in latently infected mice and in humans.

    Science.gov (United States)

    Efstathiou, S; Minson, A C; Field, H J; Anderson, J R; Wildy, P

    1986-02-01

    Herpes simplex virus-specific DNA sequences have been detected by Southern hybridization analysis in both central and peripheral nervous system tissues of latently infected mice. We have detected virus-specific sequences corresponding to the junction fragment but not the genomic termini, an observation first made by Rock and Fraser (Nature [London] 302:523-525, 1983). This "endless" herpes simplex virus DNA is both qualitatively and quantitatively stable in mouse neural tissue analyzed over a 4-month period. In addition, examination of DNA extracted from human trigeminal ganglia has shown herpes simplex virus DNA to be present in an "endless" form similar to that found in the mouse model system. Further restriction enzyme analysis of latently infected mouse brainstem and human trigeminal DNA has shown that this "endless" herpes simplex virus DNA is present in all four isomeric configurations.

  3. Detection of the specific binding on protein microarrays by oblique-incidence reflectivity difference method

    International Nuclear Information System (INIS)

    Lu, Heng; Wen, Juan; Wang, Xu; Yuan, Kun; Lu, Huibin; Zhou, Yueliang; Jin, Kuijuan; Yang, Guozhen; Li, Wei; Ruan, Kangcheng

    2010-01-01

    The specific binding between Cy5-labeled goat anti-mouse Immunoglobulin G (IgG) and mouse IgG with a concentration range from 625 to 10 4 µg ml −1 has been detected successfully by the oblique-incidence reflectivity difference (OI-RD) method in each procedure of microarray fabrication. The experimental data prove that the OI-RD method can be employed not only to distinguish the different concentrations in label-free fashion but also to detect the antibody–antigen capture. In addition, the differential treatment of the OI-RD signals can decrease the negative influences of glass slide as the microarray upholder. Therefore the OI-RD technique has promising applications for the label-free and high-throughput detection of protein microarrays

  4. Colorimetric Detection of Specific DNA Segments Amplified by Polymerase Chain Reactions

    Science.gov (United States)

    Kemp, David J.; Smith, Donald B.; Foote, Simon J.; Samaras, N.; Peterson, M. Gregory

    1989-04-01

    The polymerase chain reaction (PCR) procedure has many potential applications in mass screening. We describe here a general assay for colorimetric detection of amplified DNA. The target DNA is first amplified by PCR, and then a second set of oligonucleotides, nested between the first two, is incorporated by three or more PCR cycles. These oligonucleotides bear ligands: for example, one can be biotinylated and the other can contain a site for a double-stranded DNA-binding protein. After linkage to an immobilized affinity reagent (such as a cloned DNA-binding protein, which we describe here) and labeling with a second affinity reagent (for example, avidin) linked to horseradish peroxidase, reaction with a chromogenic substrate allows detection of the amplified DNA. This amplified DNA assay (ADA) is rapid, is readily applicable to mass screening, and uses routine equipment. We show here that it can be used to detect human immunodeficiency virus sequences specifically against a background of human DNA.

  5. Detection of Mycosphaerella graminicola in Wheat Leaves by a Microsatellite Dinucleotide Specific-Primer

    Directory of Open Access Journals (Sweden)

    Joseph-Alexander Verreet

    2011-01-01

    Full Text Available Early detection of infection is very important for efficient management of Mycosphaerella graminicola leaf blotch. To monitor and quantify the occurrence of this fungus during the growing season, a diagnostic method based on real-time PCR was developed. Standard and real-time PCR assays were developed using SYBR Green chemistry to quantify M. graminicola in vitro or in wheat samples. Microsatellite dinucleotide specific-primers were designed based on microsatellite repeats of sequences present in the genome of M. graminicola. Specificity was checked by analyzing DNA of 55 M. graminicola isolates obtained from different geographical origins. The method appears to be highly specific for detecting M. graminicola; no fluorescent signals were observed from 14 other closely related taxa. Primer (CT 7 G amplified a specific amplicon of 570 bp from all M. graminicola isolates. The primers did not amplify DNA extracted from 14 other fungal species. The approximate melting temperature (Tm of the (CT 7 G primer was 84.2 °C. The detection limit of the real-time PCR assay with the primer sets (CT 7 G is 10 fg/25 µL, as compared to 10 pg/25 µL using conventional PCR technology. From symptomless leaves, a PCR fragment could be generated two days after inoculation. Both conventional and real-time PCR could successfully detect the fungus from artificially inoculated wheat leaves. However, real-time PCR appeared much more sensitive than conventional PCR. The developed quantitative real-time PCR method proved to be rapid, sensitive, specific, cost-effective and reliable for the identification and quantification of M. graminicola in wheat.

  6. A Sensitive, Rapid, and Specific Technique for the Detection of Collagenase Using Zymography.

    Science.gov (United States)

    Prasad, Shivcharan; Roy, Ipsita

    2017-01-01

    In-gel zymography is a commonly employed tool to identify active enzymes in a quantitative and qualitative manner. In this work, apart from the incorporation of substrate which is traditionally employed in zymography, the identification of collagenase by incubation of the enzyme resolved on a polyacrylamide gel with substrate solution is described. The two methods are quite fast and result in specific detection of bacterial collagenase.

  7. Detection of neuronal tissue in meat using tissue specific DNA modifications

    Directory of Open Access Journals (Sweden)

    Harris N.

    2004-01-01

    Full Text Available A method has been developed to differentiate between non-muscle tissues such as liver, kidney and heart and that of muscle in meat samples using tissue specific DNA detection. Only muscle tissue is considered meat from the point of view of labelling (Food Labelling [Amendment] (England Regulations 2003 and Quantitative Ingredient Declaration (QUID, and also certain parts of the carcass are prohibited to be used in raw meat products (Meat Products [England] Regulations 2003. Included in the prohibited offal are brain and spinal cord. The described methodology has therefore been developed primarily to enforce labelling rules but also to contribute to the enforcement of BSE legislation on the detection of Central Nervous System (CNS tissue. The latter requires the removal of Specified Risk Material (SRM, such as bovine and ovine brain and spinal cord, from the food chain. Current methodologies for detection of CNS tissue include histological examination, analysis of cholesterol content and immunodetection. These can potentially be time consuming, less applicable to processed samples and may not be readily adapted to high throughput sample analysis. The objective of this work was therefore to develop a DNAbased detection assay that exploits the sensitivity and specificity of PCR and is potentially applicable to more highly processed food samples. For neuronal tissue, the DNA target selected was the promoter for Glial Fibrillary Acidic Protein (GFAP, a gene whose expression is restricted to astroglial cells within CNS tissue. The promoter fragments from both cattle and sheep have been isolated and key differences in the methylation patterns of certain CpG dinucleotides in the sequences from bovine and sheep brain and spinal cord and the corresponding skeletal muscle identified. These have been used to design a PCR assay exploiting Methylation Specific PCR (MSP to specifically amplify the neuronal tissue derived sequence and therefore identify the

  8. Is Neural Activity Detected by ERP-Based Brain-Computer Interfaces Task Specific?

    Directory of Open Access Journals (Sweden)

    Markus A Wenzel

    Full Text Available Brain-computer interfaces (BCIs that are based on event-related potentials (ERPs can estimate to which stimulus a user pays particular attention. In typical BCIs, the user silently counts the selected stimulus (which is repeatedly presented among other stimuli in order to focus the attention. The stimulus of interest is then inferred from the electroencephalogram (EEG. Detecting attention allocation implicitly could be also beneficial for human-computer interaction (HCI, because it would allow software to adapt to the user's interest. However, a counting task would be inappropriate for the envisaged implicit application in HCI. Therefore, the question was addressed if the detectable neural activity is specific for silent counting, or if it can be evoked also by other tasks that direct the attention to certain stimuli.Thirteen people performed a silent counting, an arithmetic and a memory task. The tasks required the subjects to pay particular attention to target stimuli of a random color. The stimulus presentation was the same in all three tasks, which allowed a direct comparison of the experimental conditions.Classifiers that were trained to detect the targets in one task, according to patterns present in the EEG signal, could detect targets in all other tasks (irrespective of some task-related differences in the EEG.The neural activity detected by the classifiers is not strictly task specific but can be generalized over tasks and is presumably a result of the attention allocation or of the augmented workload. The results may hold promise for the transfer of classification algorithms from BCI research to implicit relevance detection in HCI.

  9. Rapid and specific detection of Asian- and African-lineage Zika viruses.

    Science.gov (United States)

    Chotiwan, Nunya; Brewster, Connie D; Magalhaes, Tereza; Weger-Lucarelli, James; Duggal, Nisha K; Rückert, Claudia; Nguyen, Chilinh; Garcia Luna, Selene M; Fauver, Joseph R; Andre, Barb; Gray, Meg; Black, William C; Kading, Rebekah C; Ebel, Gregory D; Kuan, Guillermina; Balmaseda, Angel; Jaenisch, Thomas; Marques, Ernesto T A; Brault, Aaron C; Harris, Eva; Foy, Brian D; Quackenbush, Sandra L; Perera, Rushika; Rovnak, Joel

    2017-05-03

    Understanding the dynamics of Zika virus transmission and formulating rational strategies for its control require precise diagnostic tools that are also appropriate for resource-poor environments. We have developed a rapid and sensitive loop-mediated isothermal amplification (LAMP) assay that distinguishes Zika viruses of Asian and African lineages. The assay does not detect chikungunya virus or flaviviruses such as dengue, yellow fever, or West Nile viruses. The assay conditions allowed direct detection of Zika virus RNA in cultured infected cells; in mosquitoes; in virus-spiked samples of human blood, plasma, saliva, urine, and semen; and in infected patient serum, plasma, and semen samples without the need for RNA isolation or reverse transcription. The assay offers rapid, specific, sensitive, and inexpensive detection of the Asian-lineage Zika virus strain that is currently circulating in the Western hemisphere, and can also detect the African-lineage Zika virus strain using separate, specific primers. Copyright © 2017, American Association for the Advancement of Science.

  10. Specific NIST projects in support of the NIJ Concealed Weapon Detection and Imaging Program

    Science.gov (United States)

    Paulter, Nicholas G.

    1998-12-01

    The Electricity Division of the National Institute of Standards and Technology is developing revised performance standards for hand-held (HH) and walk-through (WT) metal weapon detectors, test procedures and systems for these detectors, and a detection/imaging system for finding concealed weapons. The revised standards will replace the existing National Institute of Justice (NIJ) standards for HH and WT devices and will include detection performance specifications as well as system specifications (environmental conditions, mechanical strength and safety, response reproducibility and repeatability, quality assurance, test reporting, etc.). These system requirements were obtained from the Law Enforcement and corrections Technology Advisory Council, an advisory council for the NIJ. Reproducible and repeatable test procedures and appropriate measurement systems will be developed for evaluating HH and WT detection performance. A guide to the technology and application of non- eddy-current-based detection/imaging methods (such as acoustic, passive millimeter-wave and microwave, active millimeter-wave and terahertz-wave, x-ray, etc.) Will be developed. The Electricity Division is also researching the development of a high- frequency/high-speed (300 GH to 1 THz) pulse-illuminated, stand- off, video-rate, concealed weapons/contraband imaging system.

  11. Application of Food-specific IgG Antibody Detection in Allergy Dermatosis

    Directory of Open Access Journals (Sweden)

    Yine Hu

    2015-01-01

    Full Text Available The application of food-specific IgG antibody detection in allergy dermatoses was explored. 181 patients with allergy dermatoses were diagnosed from January to September 2014 and 20 healthy subjects were selected. Fourteen kinds of food-specific IgG antibodies were detected by ELISA method among all the subjects. The positive rates of IgG antibody of the patient group and the healthy group were respectively 65.2% and 5.0%. The positive rates of IgG antibody of egg, milk, shrimp and crab took a large proportion in three groups of patients with three kinds of allergy dermatoses of urticaria, eczema and allergic dermatitis, the proportion of which was respectively 70.2%, 77.8% and 71.7%. Among urticaria and allergic dermatitis patients with positive antibody, the positive rate of children was significantly higher than that of adults (p0.05. Allergy dermatoses are closely related to food-specific IgG antibodies, and the allergy dermatoses patients have a high incidence rate of food intolerance; detecting IgG antibody in the serum of patients is of great significance for the diagnosis and treatment of allergy dermatoses.

  12. Evaluation of multiplex assay platforms for detection of influenza hemagglutinin subtype specific antibody responses.

    Science.gov (United States)

    Li, Zhu-Nan; Weber, Kimberly M; Limmer, Rebecca A; Horne, Bobbi J; Stevens, James; Schwerzmann, Joy; Wrammert, Jens; McCausland, Megan; Phipps, Andrew J; Hancock, Kathy; Jernigan, Daniel B; Levine, Min; Katz, Jacqueline M; Miller, Joseph D

    2017-05-01

    Influenza hemagglutination inhibition (HI) and virus microneutralization assays (MN) are widely used for seroprevalence studies. However, these assays have limited field portability and are difficult to fully automate for high throughput laboratory testing. To address these issues, three multiplex influenza subtype-specific antibody detection assays were developed using recombinant hemagglutinin antigens in combination with Chembio, Luminex ® , and ForteBio ® platforms. Assay sensitivity, specificity, and subtype cross-reactivity were evaluated using a panel of well characterized human sera. Compared to the traditional HI, assay sensitivity ranged from 87% to 92% and assay specificity in sera collected from unexposed persons ranged from 65% to 100% across the platforms. High assay specificity (86-100%) for A(H5N1) rHA was achieved for sera from exposed or unexposed to hetorosubtype influenza HAs. In contrast, assay specificity for A(H1N1)pdm09 rHA using sera collected from A/Vietnam/1204/2004 (H5N1) vaccinees in 2008 was low (22-30%) in all platforms. Although cross-reactivity against rHA subtype proteins was observed in each assay platform, the correct subtype specific responses were identified 78%-94% of the time when paired samples were available for analysis. These results show that high throughput and portable multiplex assays that incorporate rHA can be used to identify influenza subtype specific infections. Published by Elsevier B.V.

  13. Prostate specific antigen velocity does not aid prostate cancer detection in men with prior negative biopsy.

    Science.gov (United States)

    Vickers, Andrew J; Wolters, Tineke; Savage, Caroline J; Cronin, Angel M; O'Brien, M Frank; Roobol, Monique J; Aus, Gunnar; Scardino, Peter T; Hugosson, Jonas; Schröder, Fritz H; Lilja, Hans

    2010-09-01

    Prostate specific antigen velocity has been proposed as a marker to aid in prostate cancer detection. We determined whether prostate specific antigen velocity could predict repeat biopsy results in men with persistently increased prostate specific antigen after initial negative biopsy. We identified 1,837 men who participated in the Göteborg or Rotterdam section of the European Randomized Screening study of Prostate Cancer and who underwent 1 or more subsequent prostate biopsies after an initial negative finding. We evaluated whether prostate specific antigen velocity improved predictive accuracy beyond that of prostate specific antigen alone. Of the 2,579 repeat biopsies 363 (14%) were positive for prostate cancer, of which 44 (1.7%) were high grade (Gleason score 7 or greater). Prostate specific antigen velocity was statistically associated with cancer risk but had low predictive accuracy (AUC 0.55, p <0.001). There was some evidence that prostate specific antigen velocity improved AUC compared to prostate specific antigen for high grade cancer. However, the small increase in risk associated with high prostate specific antigen velocity (from 1.7% to 2.8% as velocity increased from 0 to 1 ng/ml per year) had questionable clinical relevance. Men with prior negative biopsy are at lower risk for prostate cancer at subsequent biopsies with high grade disease particularly rare. We found little evidence to support prostate specific antigen velocity to aid in decisions about repeat biopsy for prostate cancer. 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  14. SCAR marker specific to detect Magnaporthe grisea infecting finger millets (Eleusine coracana).

    Science.gov (United States)

    Gnanasing Jesumaharaja, L; Manikandan, R; Raguchander, T

    2016-09-01

    To determine the molecular variability and develop specific Sequence Characterized Amplified Region (SCAR) marker for the detection of Magnaporthe grisea causing blast disease in finger millet. Random amplified polymorphic DNA (RAPD) was performed with 14 isolates of M. grisea using 20 random primers. SCAR marker was developed for accurate and specific detection of M. grisea infecting only finger millets. The genetic similarity coefficient within each group and variation between the groups was observed. Among the primers, OPF-08 generated a RAPD polymorphic profile that showed common fragment of 478 bp in all the isolates. This fragment was cloned and sequenced. SCAR primers, Mg-SCAR-FP and Mg-SCAR-RP, were designed using sequence of the cloned product. The specificity of the SCAR primers was evaluated using purified DNA from M. grisea isolates from finger millets and other pathogens viz., Pyricularia oryzae, Colletotrichum gloeosporioides, Colletotrichum falcatum and Colletotrichum capcisi infecting different crops. The SCAR primers amplified only specific 460 bp fragment from DNA of M. grisea isolates and this fragment was not amplified in other pathogens tested. SCAR primers distinguish blast disease of finger millet from rice as there is no amplification in the rice blast pathogen. PCR-based SCAR marker is a convenient tool for specific and rapid detection of M. grisea in finger millets. Genetic diversity in fungal population helps in developing a suitable SCAR marker to identify the blast pathogen at the early stage of infection. © 2016 The Society for Applied Microbiology.

  15. A molecular assay for sensitive detection of pathogen-specific T-cells.

    Directory of Open Access Journals (Sweden)

    Victoria O Kasprowicz

    Full Text Available Here we describe the development and validation of a highly sensitive assay of antigen-specific IFN-γ production using real time quantitative PCR (qPCR for two reporters--monokine-induced by IFN-γ (MIG and the IFN-γ inducible protein-10 (IP10. We developed and validated the assay and applied it to the detection of CMV, HIV and Mycobacterium tuberculosis (MTB specific responses, in a cohort of HIV co-infected patients. We compared the sensitivity of this assay to that of the ex vivo RD1 (ESAT-6 and CFP-10-specific IFN-γ Elispot assay. We observed a clear quantitative correlation between the two assays (P<0.001. Our assay proved to be a sensitive assay for the detection of MTB-specific T cells, could be performed on whole blood samples of fingerprick (50 uL volumes, and was not affected by HIV-mediated immunosuppression. This assay platform is potentially of utility in diagnosis of infection in this and other clinical settings.

  16. Specific and sensitive detection of the conifer pathogen Gremmeniella abietina by nested PCR

    Directory of Open Access Journals (Sweden)

    Hansson Per

    2005-11-01

    Full Text Available Abstract Background Gremmeniella abietina (Lagerb. Morelet is an ascomycete fungus that causes stem canker and shoot dieback in many conifer species. The fungus is widespread and causes severe damage to forest plantations in Europe, North America and Asia. To facilitate early diagnosis and improve measures to control the spread of the disease, rapid, specific and sensitive detection methods for G. abietina in conifer hosts are needed. Results We designed two pairs of specific primers for G. abietina based on the 18S rDNA sequence variation pattern. These primers were validated against a wide range of fungi and 14 potential conifer hosts. Based on these specific primers, two nested PCR systems were developed. The first system employed universal fungal primers to enrich the fungal DNA targets in the first round, followed by a second round selective amplification of the pathogen. The other system employed G. abietina-specific primers in both PCR steps. Both approaches can detect the presence of G. abietina in composite samples with high sensitivity, as little as 7.5 fg G. abietina DNA in the host genomic background. Conclusion The methods described here are rapid and can be applied directly to a wide range of conifer species, without the need for fungal isolation and cultivation. Therefore, it represents a promising alternative to disease inspection in forest nurseries, plantations and quarantine control facilities.

  17. Detection of Second Order Melting Transitions in the HTSC's by Specific Heat Measurements?

    Science.gov (United States)

    Pierson, Stephen W.; Valls, Oriol T.

    1997-03-01

    The finite magnetic field phase transition in the high-temperature superconductors from the solid vortex lattice to the liquid has been under intense study recently. Detection of this melting is difficult but has been seen in magnetization and resistivity measurements. It has also been reported recently in specific heat measurements. In particular, in one case, evidence for a second order melting phase transition has been presented based on specific heat measurements.(M. Roulin, A. Junod, and E. Walker. Science 273), 1210 (1996). However, we present evidence that the feature in the specific heat data can be explained using a theory derived using the lowest-Landau-level approximation(Z. Tes)anović and A. V. Andreev, Phys. Rev. B 49, 4064 (1994) that does not invoke flux lattice melting arguments.

  18. Ultrasonographic detection of focal liver lesions: increased sensitivity and specificity with microbubble contrast agents

    International Nuclear Information System (INIS)

    Hohmann, J.; Albrecht, T.; Hoffmann, C.W.; Wolf, K.-J.

    2003-01-01

    Ultrasonography (US) is the first choice for screening patients with suspected liver lesions. However, due to a lack of contrast agents, US used to be less sensitive and specific compared with computed tomography (CT) and magnet resonance imaging (MRI). The advent of microbubble contrast agents increased both sensitivity and specificity dramatically. Rapid developments of the contrast agents as well as of special imaging techniques were made in recent years. Today numerous different US imaging methods exist which based either on Doppler or on harmonic imaging. They are using the particular behaviour of microbubbles in a sound field which varies depending on the energy of insonation (low/high mechanical index, MI) as well as on the properties of the agent themselves. Apart from just blood pool enhancement some agents have a hepatosplenic specific late phase. US imaging during this late phase using relatively high MI in phase inversion mode (harmonic imaging) or stimulated acoustic emission (SAE; Doppler method) markedly improves the detection of focal liver lesions and is also very helpful for lesion characterisation. With regards to detection, contrast enhanced US performs similarly to CT as shown by recent studies. Early results of studies using low MI imaging and the newer perfluor agents are also showing promising results for lesion detection. Low MI imaging with these agents has the advantage of real time imaging and is particularly helpful for characterisation of focal lesions based on their dynamic contrast behaviour. Apart from the techniques which based on the morphology of liver lesions there were some attempts for the detection of occult metastases or micrometastases by means of liver blood flow changes. Also in this field the use of US contrast agents appears to have advantages over formerly used non contrast-enhanced methods although no conclusive results are available yet

  19. Specificity tests of an oligonucleotide probe against food-outbreak salmonella for biosensor detection

    Science.gov (United States)

    Chen, I.-H.; Horikawa, S.; Xi, J.; Wikle, H. C.; Barbaree, J. M.; Chin, B. A.

    2017-05-01

    Phage based magneto-elastic (ME) biosensors have been shown to be able to rapidly detect Salmonella in various food systems to serve food pathogen monitoring purposes. In this ME biosensor platform, the free-standing strip-shaped magneto-elastic sensor is the transducer and the phage probe that recognizes Salmonella in food serves as the bio-recognition element. According to Sorokulova et al. at 2005, a developed oligonucleotide probe E2 was reported to have high specificity to Salmonella enterica Typhimurium. In the report, the specificity tests were focused in most of Enterobacterace groups outside of Salmonella family. Here, to understand the specificity of phage E2 to different Salmonella enterica serotypes within Salmonella Family, we further tested the specificity of the phage probe to thirty-two Salmonella serotypes that were present in the major foodborne outbreaks during the past ten years (according to Centers for Disease Control and Prevention). The tests were conducted through an Enzyme linked Immunosorbent Assay (ELISA) format. This assay can mimic probe immobilized conditions on the magnetoelastic biosensor platform and also enable to study the binding specificity of oligonucleotide probes toward different Salmonella while avoiding phage/ sensor lot variations. Test results confirmed that this oligonucleotide probe E2 was high specific to Salmonella Typhimurium cells but showed cross reactivity to Salmonella Tennessee and four other serotypes among the thirty-two tested Salmonella serotypes.

  20. Group-specific multiplex PCR detection systems for the identification of flying insect prey.

    Directory of Open Access Journals (Sweden)

    Daniela Sint

    Full Text Available The applicability of species-specific primers to study feeding interactions is restricted to those ecosystems where the targeted prey species occur. Therefore, group-specific primer pairs, targeting higher taxonomic levels, are often desired to investigate interactions in a range of habitats that do not share the same species but the same groups of prey. Such primers are also valuable to study the diet of generalist predators when next generation sequencing approaches cannot be applied beneficially. Moreover, due to the large range of prey consumed by generalists, it is impossible to investigate the breadth of their diet with species-specific primers, even if multiplexing them. However, only few group-specific primers are available to date and important groups of prey such as flying insects have rarely been targeted. Our aim was to fill this gap and develop group-specific primers suitable to detect and identify the DNA of common taxa of flying insects. The primers were combined in two multiplex PCR systems, which allow a time- and cost-effective screening of samples for DNA of the dipteran subsection Calyptratae (including Anthomyiidae, Calliphoridae, Muscidae, other common dipteran families (Phoridae, Syrphidae, Bibionidae, Chironomidae, Sciaridae, Tipulidae, three orders of flying insects (Hymenoptera, Lepidoptera, Plecoptera and coniferous aphids within the genus Cinara. The two PCR assays were highly specific and sensitive and their suitability to detect prey was confirmed by testing field-collected dietary samples from arthropods and vertebrates. The PCR assays presented here allow targeting prey at higher taxonomic levels such as family or order and therefore improve our ability to assess (trophic interactions with flying insects in terrestrial and aquatic habitats.

  1. Templated Chemistry for Sequence-Specific Fluorogenic Detection of Duplex DNA

    Science.gov (United States)

    Li, Hao; Franzini, Raphael M.; Bruner, Christopher; Kool, Eric T.

    2015-01-01

    We describe the development of templated fluorogenic chemistry for detection of specific sequences of duplex DNA in solution. In this approach, two modified homopyrimidine oligodeoxynucleotide probes are designed to bind by triple helix formation at adjacent positions on a specific purine-rich target sequence of duplex DNA. One fluorescein-labeled probe contains an α-azidoether linker to a fluorescence quencher; the second (trigger) probe carries a triarylphosphine, designed to reduce the azide and cleave the linker. The data showed that at pH 5.6 these probes yielded a strong fluorescence signal within minutes on addition to a complementary homopurine duplex DNA target. The signal increased by a factor of ca. 60, and was completely dependent on the presence of the target DNA. Replacement of cytosine in the probes with pseudoisocytosine allowed the templated chemistry to proceed readily at pH 7. Single nucleotide mismatches in the target oligonucleotide slowed the templated reaction considerably, demonstrating high sequence selectivity. The use of templated fluorogenic chemistry for detection of duplex DNAs has not been previously reported and may allow detection of double stranded DNA, at least for homopurine-homopyrimidine target sites, under native, non-disturbing conditions. PMID:20859985

  2. Detection of a Specific Biomarker for Epstein-Barr Virus Using a Polymer-Based Genosensor

    Directory of Open Access Journals (Sweden)

    Renata P. A. Balvedi

    2014-05-01

    Full Text Available This paper describes methodology for direct and indirect detections of a specific oligonucleotide for Epstein-Barr virus (EBV using electrochemical techniques. The sequence of oligonucleotide probe (EBV1 revealed a high sequence identity (100% with the EBV genome. For the development of the genosensor, EBV1 was grafted to the platform sensitized with poly(4-aminothiophenol. After that, the hybridization reaction was carried out with the complementary target (EBV2 on the modified electrode surface using ethidium bromide as DNA intercalator. The oxidation peak currents of ethidium bromide increased linearly with the values of the concentration of the complementary sequences in the range from 3.78 to 756 µmol·L−1. In nonstringent experimental conditions, this genosensor can detect 17.32 nmol·L−1 (three independent experiments of oligonucleotide target, discriminating between complementary and non-complementary oligonucleotides, as well as differentiating one-base mismatch, as required for detection of genetic diseases caused by point mutations. The biosensor also displayed high specificity to the EBV target with elimination of interference from mix (alanine, glucose, uric acid, ascorbic acid, bovine serum albumin (BSA, glutamate and glycine and good stability (120 days. In addition, it was possible to observe differences between hybridized and non-hybridized surfaces through atomic force microscopy.

  3. On the importance of controlling film architecture in detecting prostate specific antigen

    Science.gov (United States)

    Graça, Juliana Santos; Miyazaki, Celina Massumi; Shimizu, Flavio Makoto; Volpati, Diogo; Mejía-Salazar, J. R.; Oliveira, Osvaldo N., Jr.; Ferreira, Marystela

    2018-03-01

    Immunosensors made with nanostructured films are promising for detecting cancer biomarkers, even at early stages of the disease, but this requires control of film architecture to preserve the biological activity of immobilized antibodies. In this study, we used electrochemical impedance spectroscopy (EIS) to detect Prostate Specific Antigen (PSA) with immunosensors produced with layer-by-layer (LbL) films containing anti-PSA antibodies in two distinct film architectures. The antibodies were either adsorbed from solutions in which they were free, or from solutions where they were incorporated into liposomes of dipalmitoyl phosphatidyl glycerol (DPPG). Incorporation into DPPG liposomes was confirmed with surface plasmon resonance experiments, while the importance of electrostatic interactions on the electrical response was highlighted using the Finite Difference Time-Domain Method (FDTD). The sensitivity of both architectures was sufficient to detect the threshold value to diagnose prostate cancer (ca. 4 ng mL-1). In contrast to expectation, the sensor with the antibodies incorporated into DPPG liposomes had lower sensitivity, though the range of concentrations amenable to detection increased, according to the fitting of the EIS data using the Langmuir-Freundlich adsorption model. The performance of the two film architectures was compared qualitatively by plotting the data with a multidimensional projection technique, which constitutes a generic approach for optimizing immunosensors and other types of sensors.

  4. Detection of virus-specific intrathecally synthesised immunoglobulin G with a fully automated enzyme immunoassay system

    Directory of Open Access Journals (Sweden)

    Weissbrich Benedikt

    2007-05-01

    Full Text Available Abstract Background The determination of virus-specific immunoglobulin G (IgG antibodies in cerebrospinal fluid (CSF is useful for the diagnosis of virus associated diseases of the central nervous system (CNS and for the detection of a polyspecific intrathecal immune response in patients with multiple sclerosis. Quantification of virus-specific IgG in the CSF is frequently performed by calculation of a virus-specific antibody index (AI. Determination of the AI is a demanding and labour-intensive technique and therefore automation is desirable. We evaluated the precision and the diagnostic value of a fully automated enzyme immunoassay for the detection of virus-specific IgG in serum and CSF using the analyser BEP2000 (Dade Behring. Methods The AI for measles, rubella, varicella-zoster, and herpes simplex virus IgG was determined from pairs of serum and CSF samples of patients with viral CNS infections, multiple sclerosis and of control patients. CSF and serum samples were tested simultaneously with reference to a standard curve. Starting dilutions were 1:6 and 1:36 for CSF and 1:1386 and 1:8316 for serum samples. Results The interassay coefficient of variation was below 10% for all parameters tested. There was good agreement between AIs obtained with the BEP2000 and AIs derived from the semi-automated reference method. Conclusion Determination of virus-specific IgG in serum-CSF-pairs for calculation of AI has been successfully automated on the BEP2000. Current limitations of the assay layout imposed by the analyser software should be solved in future versions to offer more convenience in comparison to manual or semi-automated methods.

  5. Sensitivity and specificity of oral HPV detection for HPV-positive head and neck cancer.

    Science.gov (United States)

    Gipson, Brooke J; Robbins, Hilary A; Fakhry, Carole; D'Souza, Gypsyamber

    2018-02-01

    The incidence of HPV-related head and neck squamous cell carcinoma (HPV-HNSCC) is increasing. Oral samples are easy and non-invasive to collect, but the diagnostic accuracy of oral HPV detection methods for classifying HPV-positive HNSCC tumors has not been well explored. In a systematic review, we identified eight studies of HNSCC patients meeting our eligibility criteria of having: (1) HPV detection in oral rinse or oral swab samples, (2) tumor HPV or p16 testing, (3) a publication date within the last 10 years (January 2007-May 2017, as laboratory methods change), and (4) at least 15 HNSCC cases. Data were abstracted from each study and a meta-analysis performed to calculate sensitivity and specificity. Eight articles meeting inclusion criteria were identified. Among people diagnosed with HNSCC, oral HPV detection has good specificity (92%, 95% CI = 82-97%) and moderate sensitivity (72%, 95% CI = 45-89%) for HPV-positive HNSCC tumor. Results were similar when restricted to studies with only oropharyngeal cancer cases, with oral rinse samples, or testing for HPV16 DNA (instead of any oncogenic HPV) in the oral samples. Among those who already have HNSCC, oral HPV detection has few false-positives but may miss one-half to one-quarter of HPV-related cases (false-negatives). Given these findings in cancer patients, the utility of oral rinses and swabs as screening tests for HPV-HNSCC among healthy populations is probably limited. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Detection of MPL mutations by a novel allele-specific PCR-based strategy.

    Science.gov (United States)

    Furtado, Larissa V; Weigelin, Helmut C; Elenitoba-Johnson, Kojo S J; Betz, Bryan L

    2013-11-01

    MPL mutation testing is recommended in patients with suspected primary myelofibrosis or essential thrombocythemia who lack the JAK2 V617F mutation. MPL mutations can occur at allelic levels below 15%, which may escape detection by commonly used mutation screening methods such as Sanger sequencing. We developed a novel multiplexed allele-specific PCR assay capable of detecting most recurrent MPL exon 10 mutations associated with primary myelofibrosis and essential thrombocythemia (W515L, W515K, W515A, and S505N) down to a sensitivity of 2.5% mutant allele. Test results were reviewed from 15 reference cases and 1380 consecutive specimens referred to our laboratory for testing. Assay performance was compared to Sanger sequencing across a series of 58 specimens with MPL mutations. Positive cases consisted of 45 with W515L, 6 with S505N, 5 with W515K, 1 with W515A, and 1 with both W515L and S505N. Seven cases had mutations below 5% that were undetected by Sanger sequencing. Ten additional cases had mutation levels between 5% and 15% that were not consistently detected by sequencing. All results were easily interpreted in the allele-specific test. This assay offers a sensitive and reliable solution for MPL mutation testing. Sanger sequencing appears insufficiently sensitive for robust MPL mutation detection. Our data also suggest the relative frequency of S505N mutations may be underestimated, highlighting the necessity for inclusion of this mutation in MPL test platforms. Copyright © 2013 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  7. Detection of porcine endogenous retrovirus (PERV) using highly specific antisera against Gag and Env

    International Nuclear Information System (INIS)

    Fischer, Nicole; Krach, Ulrich; Niebert, Marcus; Toenjes, Ralf R.

    2003-01-01

    Porcine endogenous retroviruses (PERV) are considered an obstacle to the safe use of cells, tissues, and organs from pigs in the course of xenotransplantation. Thus, the detection of viral proteins and of a potential PERV infection is of major interest. Recently, we have published the generation of a highly specific antiserum directed against the nucleocapsid (p10) of PERV (Xenotransplantation 7 (2000), 221). Here we present new peptide-antisera specific to the capsid protein (p30) and the surface molecule of PERV class B (SU, gp70(B)) as well as the transmembrane moiety of the envelope protein (TM, p15E) of PERV which showed functionality in several immunological assays, such as immunoblots, immunofluorescence, and immunogold staining. Thus, these antisera can be used as tools for the identification of viral proteins in basic research as well as clinical trials

  8. Sensitivity and specificity of radionuclide equilibrium angiocardiography for detection of hemodynamically significant secundum atrial septal defect

    Energy Technology Data Exchange (ETDEWEB)

    Brunotte, F.; Laurens, M.H.; Itty, C.; Robert, J.; Cloez, J.L.; Marcon, F.; Pernot, C.

    1986-12-01

    To determine the value, of gated equilibrium angiography in secundum atrial septal defect (ASD) in children, the first pass pulmonic/systemic flow ratio (Qp/Qs) was compared with diastolic count ratio (DCR) and stroke count ratio (SCR) of the two ventricles. In 50 children we have found a correlation between Qp/Qs and DCR (r=0.71) and between Qp/Qs and SCR (r=0.66). For detection of significant atrial shunt (Qp/Qs>1.5) the sensitivity of DCR>2 was 0.81 and the specificity 0.75. For SCR>1.5 we sensitivity and specificity values of 0.87 and 0.71 respectively. Left and right ventricular ejection fractions were normal (0.67+-0.08 and 0.50+-0.07).

  9. Speech-specific audiovisual perception affects identification but not detection of speech

    DEFF Research Database (Denmark)

    Eskelund, Kasper; Andersen, Tobias

    Speech perception is audiovisual as evidenced by the McGurk effect in which watching incongruent articulatory mouth movements can change the phonetic auditory speech percept. This type of audiovisual integration may be specific to speech or be applied to all stimuli in general. To investigate...... of audiovisual integration specific to speech perception. However, the results of Tuomainen et al. might have been influenced by another effect. When observers were naïve, they had little motivation to look at the face. When informed, they knew that the face was relevant for the task and this could increase...... visual detection task. In our first experiment, observers presented with congruent and incongruent audiovisual sine-wave speech stimuli did only show a McGurk effect when informed of the speech nature of the stimulus. Performance on the secondary visual task was very good, thus supporting the finding...

  10. Direct, Specific and Rapid Detection of Staphylococcal Proteins and Exotoxins Using a Multiplex Antibody Microarray.

    Directory of Open Access Journals (Sweden)

    Bettina Stieber

    Full Text Available S. aureus is a pathogen in humans and animals that harbors a wide variety of virulence factors and resistance genes. This bacterium can cause a wide range of mild to life-threatening diseases. In the latter case, fast diagnostic procedures are important. In routine diagnostic laboratories, several genotypic and phenotypic methods are available to identify S. aureus strains and determine their resistances. However, there is a demand for multiplex routine diagnostic tests to directly detect staphylococcal toxins and proteins.In this study, an antibody microarray based assay was established and validated for the rapid detection of staphylococcal markers and exotoxins. The following targets were included: staphylococcal protein A, penicillin binding protein 2a, alpha- and beta-hemolysins, Panton Valentine leukocidin, toxic shock syndrome toxin, enterotoxins A and B as well as staphylokinase. All were detected simultaneously within a single experiment, starting from a clonal culture on standard media. The detection of bound proteins was performed using a new fluorescence reading device for microarrays.110 reference strains and clinical isolates were analyzed using this assay, with a DNA microarray for genotypic characterization performed in parallel. The results showed a general high concordance of genotypic and phenotypic data. However, genotypic analysis found the hla gene present in all S. aureus isolates but its expression under given conditions depended on the clonal complex affiliation of the actual isolate.The multiplex antibody assay described herein allowed a rapid and reliable detection of clinically relevant staphylococcal toxins as well as resistance- and species-specific markers.

  11. Breast density and mode of detection in relation to breast cancer specific survival: a cohort study

    International Nuclear Information System (INIS)

    Olsson, Åsa; Sartor, Hanna; Borgquist, Signe; Zackrisson, Sophia; Manjer, Jonas

    2014-01-01

    The aim of this study was to examine breast density in relation to breast cancer specific survival and to assess if this potential association was modified by mode of detection. An additional aim was to study whether the established association between mode of detection and survival is modified by breast density. The study included 619 cases from a prospective cohort, The Malmö Diet and Cancer Study. Breast density estimated qualitatively, was analyzed in relation to breast cancer death, in non-symptomatic and symptomatic women, using Cox regression calculating hazard ratios (HR) with 95% confidence intervals. Adjustments were made in several steps for; diagnostic age, tumour size, axillary lymph node involvement, grade, hormone receptor status, body mass index (baseline), diagnostic period, use of hormone replacement therapy at diagnosis and mode of detection. Detection mode in relation to survival was analyzed stratified for breast density. Differences in HR following different adjustments were analyzed by Freedmans%. After adjustment for age and other prognostic factors, women with dense, as compared to fatty breasts, had an increased risk of breast cancer death, HR 2.56:1.07-6.11, with a statistically significant trend over density categories, p = 0.04. In the stratified analysis, the effect was less pronounced in non-symptomatic women, HR 2.04:0.49-8.49 as compared to symptomatic, HR 3.40:1.06-10.90. In the unadjusted model, symptomatic women had a higher risk of breast cancer death, regardless of breast density. Analyzed by Freedmans%, age, tumour size, lymph nodes, grade, diagnostic period, ER and PgR explained 55.5% of the observed differences in mortality between non-symptomatic and symptomatic cases. Additional adjustment for breast density caused only a minor change. High breast density at diagnosis may be associated with decreased breast cancer survival. This association appears to be stronger in women with symptomatic cancers but breast density could

  12. A Simple and Specific Noncompetitive ELISA Method for HT-2 Toxin Detection

    Directory of Open Access Journals (Sweden)

    Henri O. Arola

    2017-04-01

    Full Text Available We developed an HT-2 toxin-specific simple ELISA format with a positive read-out. The assay is based on an anti-immune complex (IC scFv antibody fragment, which is genetically fused with alkaline phosphatase (AP. The anti-IC antibody specifically recognizes the IC between a primary anti-HT-2 toxin Fab fragment and an HT-2 toxin molecule. In the IC ELISA format, the sample is added together with the scFv-AP antibody to the ELISA plate coated with the primary antibody. After 15 min of incubation and a washing step, the ELISA response is read. A competitive ELISA including only the primary antibody recognizes both HT-2 and T-2 toxins. The anti-IC antibody makes the assay specific for HT-2 toxin, and the IC ELISA is over 10 times more sensitive compared to the competitive assay. Three different naturally contaminated matrices: wheat, barley and oats, were used to evaluate the assay performance with real samples. The corresponding limits of detection were 0.3 ng/mL (13 µg/kg, 0.1 ng/mL (4 µg/kg and 0.3 ng/mL (16 µg/kg, respectively. The IC ELISA can be used for screening HT-2 toxin specifically and in relevant concentration ranges from all three tested grain matrices.

  13. Sensitivity and specificity of parallel or serial serological testing for detection of canine Leishmania infection

    Directory of Open Access Journals (Sweden)

    Mauro Maciel de Arruda

    2016-01-01

    Full Text Available In Brazil, human and canine visceral leishmaniasis (CVL caused byLeishmania infantum has undergone urbanisation since 1980, constituting a public health problem, and serological tests are tools of choice for identifying infected dogs. Until recently, the Brazilian zoonoses control program recommended enzyme-linked immunosorbent assays (ELISA and indirect immunofluorescence assays (IFA as the screening and confirmatory methods, respectively, for the detection of canine infection. The purpose of this study was to estimate the accuracy of ELISA and IFA in parallel or serial combinations. The reference standard comprised the results of direct visualisation of parasites in histological sections, immunohistochemical test, or isolation of the parasite in culture. Samples from 98 cases and 1,327 noncases were included. Individually, both tests presented sensitivity of 91.8% and 90.8%, and specificity of 83.4 and 53.4%, for the ELISA and IFA, respectively. When tests were used in parallel combination, sensitivity attained 99.2%, while specificity dropped to 44.8%. When used in serial combination (ELISA followed by IFA, decreased sensitivity (83.3% and increased specificity (92.5% were observed. Serial testing approach improved specificity with moderate loss in sensitivity. This strategy could partially fulfill the needs of public health and dog owners for a more accurate diagnosis of CVL.

  14. Non-crosslinking gold nanoprobe-LAMP for simple, colorimetric, and specific detection of Salmonella typhi

    International Nuclear Information System (INIS)

    Bozorgmehr, Ali; Yazdanparast, Razieh; Mollasalehi, Hamidreza

    2016-01-01

    In this study, we developed a non-crosslinking gold nanoprobe loop-mediated isothermal amplification (LAMP) method for nanodiagnosis of bacterial typhoid fever source, Salmonella typhi. Therefore, a unique region in the S. typhi genomic DNA was targeted for LAMP amplification using a specific set of four precisely designed primers. Also, for specific colorimetric visualization of the amplicons, a thiolated oligonucleotide probe, complementary to the single-stranded loop region of the amplicons between F2 and F1C segments, was designed. The probe was bound to the surface of gold nanoparticles via covalent bonds. Increasing the salt concentration in the detection reaction medium led to aggregation of nanoprobes in the blank and the negative vessels in a time-dependent form. That was followed by a change in the surface plasmon resonance (SPR) leading to blue/black color that was observable by the naked eyes after about 5 min. Meanwhile, the original pink/red color was retained in the positive sample due to the large interparticle spaces and the stability against the ionic strength elevation which persisted for about 30 min. The whole process of DNA extraction, amplification, and detection took less than 2 h with a sensitivity of 20 CFU/ml. The developed gold nanoprobe-LAMP could serve as a simple, rapid, and cost-effective method for nanodiagnosis of S. typhi in point-of-need applications.

  15. Value of serum TORCH-specific antibody detection in assessment of neonatal jaundice

    Directory of Open Access Journals (Sweden)

    Guang-Hua Dai

    2016-06-01

    Full Text Available Objective: To study the value of serum TORCH-specific antibody detection in assessment of neonatal jaundice. Methods: A total of 70 cases of children with neonatal jaundice were selected as jaundice group, 70 cases of healthy newborn were the control group, and serum serum TORCH-specific antibody content as well as heart function, liver function, kidney function and nerve function indicators were detected. Results: Serum TOX-IgM, RV-IgM, CMV-IgM and HSV-IgM positive rate and content of jaundice group were significantly higher than those of control group; serum CK-MB, cTnI, AST, ALT, Cys-C, RBP, MBP, S100β and NSE content of TORCH-positive children were significantly higher than those of TORCHnegative children, and BDNF, NT-3, NT-4 and NGF content were significantly lower than those of TORCH-negative children; T1WI signal of pallidum MRI of TORCH-positive children was significantly higher than that of TORCH-negative children. Conclusions: Serum TORCHspecific antibodies significantly increase in children with neonatal jaundice and can assess the degree of bilirubin metabolism disorder and the degree of target organ damage.

  16. Non-crosslinking gold nanoprobe-LAMP for simple, colorimetric, and specific detection of Salmonella typhi

    Energy Technology Data Exchange (ETDEWEB)

    Bozorgmehr, Ali; Yazdanparast, Razieh, E-mail: ryazdan@ut.ac.ir [University of Tehran, Institute of Biochemistry and Biophysics (Iran, Islamic Republic of); Mollasalehi, Hamidreza [Shahid Beheshti University, Protein Research Center (Iran, Islamic Republic of)

    2016-12-15

    In this study, we developed a non-crosslinking gold nanoprobe loop-mediated isothermal amplification (LAMP) method for nanodiagnosis of bacterial typhoid fever source, Salmonella typhi. Therefore, a unique region in the S. typhi genomic DNA was targeted for LAMP amplification using a specific set of four precisely designed primers. Also, for specific colorimetric visualization of the amplicons, a thiolated oligonucleotide probe, complementary to the single-stranded loop region of the amplicons between F2 and F1C segments, was designed. The probe was bound to the surface of gold nanoparticles via covalent bonds. Increasing the salt concentration in the detection reaction medium led to aggregation of nanoprobes in the blank and the negative vessels in a time-dependent form. That was followed by a change in the surface plasmon resonance (SPR) leading to blue/black color that was observable by the naked eyes after about 5 min. Meanwhile, the original pink/red color was retained in the positive sample due to the large interparticle spaces and the stability against the ionic strength elevation which persisted for about 30 min. The whole process of DNA extraction, amplification, and detection took less than 2 h with a sensitivity of 20 CFU/ml. The developed gold nanoprobe-LAMP could serve as a simple, rapid, and cost-effective method for nanodiagnosis of S. typhi in point-of-need applications.

  17. Prostate Cancer Detection and Prognosis: From Prostate Specific Antigen (PSA) to Exosomal Biomarkers.

    Science.gov (United States)

    Filella, Xavier; Foj, Laura

    2016-10-26

    Prostate specific antigen (PSA) remains the most used biomarker in the management of early prostate cancer (PCa), in spite of the problems related to false positive results and overdiagnosis. New biomarkers have been proposed in recent years with the aim of increasing specificity and distinguishing aggressive from non-aggressive PCa. The emerging role of the prostate health index and the 4Kscore is reviewed in this article. Both are blood-based tests related to the aggressiveness of the tumor, which provide the risk of suffering PCa and avoiding negative biopsies. Furthermore, the use of urine has emerged as a non-invasive way to identify new biomarkers in recent years, including the PCA3 and TMPRSS2:ERG fusion gene. Available results about the PCA3 score showed its usefulness to decide the repetition of biopsy in patients with a previous negative result, although its relationship with the aggressiveness of the tumor is controversial. More recently, aberrant microRNA expression in PCa has been reported by different authors. Preliminary results suggest the utility of circulating and urinary microRNAs in the detection and prognosis of PCa. Although several of these new biomarkers have been recommended by different guidelines, large prospective and comparative studies are necessary to establish their value in PCa detection and prognosis.

  18. Metal-organic gel enhanced fluorescence anisotropy for sensitive detection of prostate specific antigen

    Science.gov (United States)

    Zhao, Ting Ting; Peng, Zhe Wei; Yuan, Dan; Zhen, Shu Jun; Huang, Cheng Zhi; Li, Yuan Fang

    2018-03-01

    In this contribution, we demonstrated that Cu-based metal-organic gel (Cu-MOG) was able to serve as a novel amplification platform for fluorescence anisotropy (FA) assay for the first time, which was confirmed by the sensitive detection of a common cancer biomarker, prostate specific antigen (PSA). The dye-labeled probe aptamer (PA) product was adsorbed onto the benzimidazole derivative-containing Cu-MOG via electrostatic incorporation and strong π-π stacking interactions, which significantly increased the FA value due to the enlargement of the molecular volume of the PA/Cu-MOG complex. With the introduction of target PSA, the FA value was obviously decreased on account of the specific recognition between PSA and PA which resulted in the detachment of PA from the surface of MOG. The linear range was from 0.5-8 ng/mL, with a detection limit of 0.33 ng/mL. Our work has thus helped to demonstrate promising application of MOG material in the fields of biomolecules analysis and disease diagnosis.

  19. Measuring the Electronic Properties of DNA-Specific Schottky Diodes Towards Detecting and Identifying Basidiomycetes DNA

    Science.gov (United States)

    Periasamy, Vengadesh; Rizan, Nastaran; Al-Ta’ii, Hassan Maktuff Jaber; Tan, Yee Shin; Tajuddin, Hairul Annuar; Iwamoto, Mitsumasa

    2016-01-01

    The discovery of semiconducting behavior of deoxyribonucleic acid (DNA) has resulted in a large number of literatures in the study of DNA electronics. Sequence-specific electronic response provides a platform towards understanding charge transfer mechanism and therefore the electronic properties of DNA. It is possible to utilize these characteristic properties to identify/detect DNA. In this current work, we demonstrate a novel method of DNA-based identification of basidiomycetes using current-voltage (I-V) profiles obtained from DNA-specific Schottky barrier diodes. Electronic properties such as ideality factor, barrier height, shunt resistance, series resistance, turn-on voltage, knee-voltage, breakdown voltage and breakdown current were calculated and used to quantify the identification process as compared to morphological and molecular characterization techniques. The use of these techniques is necessary in order to study biodiversity, but sometimes it can be misleading and unreliable and is not sufficiently useful for the identification of fungi genera. Many of these methods have failed when it comes to identification of closely related species of certain genus like Pleurotus. Our electronics profiles, both in the negative and positive bias regions were however found to be highly characteristic according to the base-pair sequences. We believe that this simple, low-cost and practical method could be useful towards identifying and detecting DNA in biotechnology and pathology. PMID:27435636

  20. Rapid and Highly Sensitive Non-Competitive Immunoassay for Specific Detection of Nodularin

    Directory of Open Access Journals (Sweden)

    Sultana Akter

    2017-09-01

    Full Text Available Nodularin (NOD is a cyclic penta-peptide hepatotoxin mainly produced by Nodularia spumigena, reported from the brackish water bodies of various parts of the world. It can accumulate in the food chain and, for safety reasons, levels of NOD not only in water bodies but also in food matrices are of interest. Here, we report on a non-competitive immunoassay for the specific detection of NOD. A phage display technique was utilized to interrogate a synthetic antibody phage library for binders recognizing NOD bound to an anti-ADDA (3-Amino-9-methoxy-2,6,8-trimethyl-10-phenyldeca-4(E,6(E-dienoic acid monoclonal antibody (Mab. One of the obtained immunocomplex binders, designated SA32C11, showed very high specificity towards nodularin-R (NOD-R over to the tested 10 different microcystins (microcystin-LR, -dmLR, -RR, -dmRR, -YR, -LY, -LF, -LW, -LA, -WR. It was expressed in Escherichia coli as a single chain antibody fragment (scFv fusion protein and used to establish a time-resolved fluorometry-based assay in combination with the anti-ADDA Mab. The detection limit (blank + 3SD of the immunoassay, with a total assay time of 1 h 10 min, is 0.03 µg/L of NOD-R. This represents the most sensitive immunoassay method for the specific detection of NOD reported so far. The assay was tested for its performance to detect NOD using spiked (0.1 to 3 µg/L of NOD-R water samples including brackish sea and coastal water and the recovery ranged from 79 to 127%. Furthermore, a panel of environmental samples, including water from different sources, fish and other marine tissue specimens, were analyzed for NOD using the assay. The assay has potential as a rapid screening tool for the analysis of a large number of water samples for the presence of NOD. It can also find applications in the analysis of the bioaccumulation of NOD in marine organisms and in the food chain.

  1. His-tag ELISA for the detection of humoral tumor-specific immunity

    Directory of Open Access Journals (Sweden)

    Disis Mary L

    2008-05-01

    Full Text Available Abstract Background The application of high throughput molecular techniques such as SEREX are resulting in the identification of a multitude of tumor associated antigens. As newly identified antigens are incorporated into a variety of clinical trials, standardization of immunologic monitoring methods becomes increasingly important. We questioned whether mammalian cell expression of a histadine-linked human protein could be used to produce antigen suitable for detecting tumor-specific humoral immunity and whether such an assay could be amenable to standardization for clinical use. Methods We designed a his-tagged capture ELISA based on lysate from genetically engineered CHO cells for detection of antibodies to insulin-like growth factor binding protein 2, a novel tumor antigen. We performed technical and preliminary clinical validation studies, including comparison to a standard indirect ELISA based on commercially prepared recombinant antigen. Results The his-tagged capture ELISA could be standardized. Precision experiments resulted in CVs 2 values of 0.99. In comparison to Western blot analysis, his-tag and indirect ELISA accurately identified 88% and 93% of samples, respectively. Sample concordance between capture and indirect assays was highly significant (p = 0.003. Furthermore, significantly greater levels of IGFBP-2 antibody immunity were found in cancer patients compared to normal controls (p = 0.008. Conclusion A genetically engineered cell lysate based ELISA can be amenable to standardization and can detect increased levels of antibody immunity to tumor-associated antigen in cancer patients compared to non tumor-bearing healthy controls.

  2. Development of a Highly Specific Fluorescence Immunoassay for Detection of Diisobutyl Phthalate in Edible Oil Samples.

    Science.gov (United States)

    Cui, Xiping; Wu, Panpan; Lai, Dan; Zheng, Shengwu; Chen, Yingshan; Eremin, Sergei A; Peng, Wei; Zhao, Suqing

    2015-10-28

    The diisobutyl phthalate (DiBP) hapten containing an amino group was synthesized successfully, and the polyclonal antibody against 4-amino phthalate-bovine serum albumin (BSA) was developed. On the basis of the polyclonal antibody, a rapid and sensitive indirect competitive fluorescence immunoassay (icFIA) has been established to detect DiBP in edible oil samples for the first time. Under the optimized conditions, the quantitative working range of the icFIA was from 10.47 to 357.06 ng/mL (R(2) = 0.991), exhibiting a detection limit of 5.82 ng/mL. In this assay, the specific results showed that other similar phthalates did not significantly interfere with the analysis, with the cross-reactivity less than 1.5%, except for that of DiBAP. Thereafter, DiBP contamination in edible oil samples was detected by icFIA, with the recovery being from 79 to 103%. Furthermore, the reliability of icFIA was validated by gas chromatography-mass spectrometry (GC-MS). Therefore, the developed icFIA is suitable for monitoring DiBP in some edible oil samples.

  3. Transrectal ultrasound in detecting prostate cancer compared with serum total prostate-specific antigen levels

    International Nuclear Information System (INIS)

    Tamsel, S.; Killi, R.; Demirpolat, G.; Hekimgil, M.; Soydan, S.; Altay, B.

    2008-01-01

    We carried out a retrospective study to review the efficiency of grey-scale transrectal ultrasonography (TRUS) in detecting prostate cancer compared with the data in recent published work, including alternative imaging methods of the prostate gland. Our study group consisted of 830 patients who underwent TRUS-guided biopsy of the prostate between May 2000 and June 2004. The relation between abnormal TRUS findings and serum total prostate-specific antigen (tPSA) levels was evaluated in patients with prostate cancer who were divided into three different groups according to serum tPSA levels. Group I included patients with tPSA levels of 4-9.9 ng/mL, group II included tPSA levels of 10-19.9 ng/mL and group III included patients with tPSA levels of 20 ng/mL or more. In general, TRUS detected 185 (64%) of 291 cancers with a specificity of 89%, a PPV of 76% and an accuracy of 80%. TRUS findings enabled the correct identification of 22 (56%) of the 39 cancers in group I, 28 (30%) of the 93 cancers in group II and 135 (85%) of the 159 cancers in group III. In conclusion, TRUS alone has a limited potential to identify prostate cancer, especially in patients with tPSA levels lower than 20 ng/mL. Therefore, increased numbers of systematically placed biopsy cores must be taken or alternative imaging methods are required to direct TRUS-guided biopsy for improving prostate cancer detection.

  4. Open-Source Radiation Exposure Extraction Engine (RE3) with Patient-Specific Outlier Detection.

    Science.gov (United States)

    Weisenthal, Samuel J; Folio, Les; Kovacs, William; Seff, Ari; Derderian, Vana; Summers, Ronald M; Yao, Jianhua

    2016-08-01

    We present an open-source, picture archiving and communication system (PACS)-integrated radiation exposure extraction engine (RE3) that provides study-, series-, and slice-specific data for automated monitoring of computed tomography (CT) radiation exposure. RE3 was built using open-source components and seamlessly integrates with the PACS. RE3 calculations of dose length product (DLP) from the Digital imaging and communications in medicine (DICOM) headers showed high agreement (R (2) = 0.99) with the vendor dose pages. For study-specific outlier detection, RE3 constructs robust, automatically updating multivariable regression models to predict DLP in the context of patient gender and age, scan length, water-equivalent diameter (D w), and scanned body volume (SBV). As proof of concept, the model was trained on 811 CT chest, abdomen + pelvis (CAP) exams and 29 outliers were detected. The continuous variables used in the outlier detection model were scan length (R (2)  = 0.45), D w (R (2) = 0.70), SBV (R (2) = 0.80), and age (R (2) = 0.01). The categorical variables were gender (male average 1182.7 ± 26.3 and female 1047.1 ± 26.9 mGy cm) and pediatric status (pediatric average 710.7 ± 73.6 mGy cm and adult 1134.5 ± 19.3 mGy cm).

  5. Circulating microRNAs as specific biomarkers for breast cancer detection.

    Directory of Open Access Journals (Sweden)

    Enders K O Ng

    Full Text Available We previously showed microRNAs (miRNAs in plasma are potential biomarkers for colorectal cancer detection. Here, we aimed to develop specific blood-based miRNA assay for breast cancer detection.TaqMan-based miRNA profiling was performed in tumor, adjacent non-tumor, corresponding plasma from breast cancer patients, and plasma from matched healthy controls. All putative markers identified were verified in a training set of breast cancer patients. Selected markers were validated in a case-control cohort of 170 breast cancer patients, 100 controls, and 95 other types of cancers and then blindly validated in an independent set of 70 breast cancer patients and 50 healthy controls. Profiling results showed 8 miRNAs were concordantly up-regulated and 1 miRNA was concordantly down-regulated in both plasma and tumor tissue of breast cancer patients. Of the 8 up-regulated miRNAs, only 3 were significantly elevated (p<0.0001 before surgery and reduced after surgery in the training set. Results from the validation cohort showed that a combination of miR-145 and miR-451 was the best biomarker (p<0.0001 in discriminating breast cancer from healthy controls and all other types of cancers. In the blind validation, these plasma markers yielded Receiver Operating Characteristic (ROC curve area of 0.931. The positive predictive value was 88% and the negative predictive value was 92%. Altered levels of these miRNAs in plasma have been detected not only in advanced stages but also early stages of tumors. The positive predictive value for ductal carcinoma in situ (DCIS cases was 96%.These results suggested that these circulating miRNAs could be a potential specific biomarker for breast cancer screening.

  6. Sequence-specific validation of LAMP amplicons in real-time optomagnetic detection of Dengue serotype 2 synthetic DNA

    DEFF Research Database (Denmark)

    Minero, Gabriel Khose Antonio; Nogueira, Catarina; Rizzi, Giovanni

    2017-01-01

    We report on an optomagnetic technique optimised for real-time molecular detection of Dengue fever virus under ideal as well as non-ideal laboratory conditions using two different detection approaches. The first approach is based on the detection of the hydrodynamic volume of streptavidin coated...... magnetic nanoparticles attached to biotinylated LAMP amplicons. We demonstrate detection of sub-femtomolar Dengue DNA target concentrations in the ideal contamination-free lab environment within 20 min. The second detection approach is based on sequence-specific binding of functionalised magnetic...... claim detection of down to 100 fM of Dengue target after 20 min of LAMP with a contamination background....

  7. PCR approach for rapid detection of Escherichia coli in tempe using a specific primer

    Directory of Open Access Journals (Sweden)

    Siti Harnina Bintari

    2014-12-01

    Full Text Available Tempe known as a traditional fermented food originated from Indonesia. It has a unique flavour and texture. It also contains high protein and usually serves to substitute meat, fish, or egg as a complement to rice. The manufacture process of Tempe is quite complex and mostly, the traditional process has not employed the hygienic standard. In the process of Tempe making, there are two critical stages of the whole process; i.e. soaking of soybeans and solid state fermentation by Rhizopus sp. During the process, foodborne pathogen bacteria such as Escherichia coli could contaminate the product of Tempe. The bacterial contamination could be revealed through culture dependent methods which is costly, laborious, and time consuming. Therefore, the culture-independent method such as polymerase chain reaction using a specific primer could be applied to detect target microorganism to save time and labour. In this study, thirty-one Tempe samples collected from different manufacturers in Semarang, Central Java, Indonesia were analysed by PCR. In order to obtain the bacterial genomic DNA, a modified Chelex 100-Microwave method was employed. The results of DNA extraction showed that the method was an applicable method. It gave high quantity and quality of DNA; therefore, it could be applied in the PCR reaction. The DNA samples were employed in PCR for detection of Escherichia coli using Ecoli706F/R. It was found that 27 out of 31 samples were detected having Escherichia coli contamination showed by the presence of the amplified product size 706 bp. The application of this method could significantly reduce costs and time of analysis in the laboratory. Further response after E. coli were detected could be employed, including investigation of the critical factors in Tempe manufacturing process which allowed E. coli contamination.

  8. Specific detection of Pectobacterium carotovorum by loop-mediated isothermal amplification.

    Science.gov (United States)

    Yasuhara-Bell, Jarred; Marrero, Glorimar; De Silva, Asoka; Alvarez, Anne M

    2016-12-01

    Potatoes are an important agroeconomic crop worldwide and maceration diseases caused by pectolytic bacterial pathogens result in significant pre- and post-harvest losses. Pectobacterium carotovorum shares a common host range with other Pectobacterium spp. and other members of the Enterobacteriaceae, such as Dickeya spp. As these pathogens cannot be clearly differentiated on the basis of the symptoms they cause, improved methods of identification are critical for the determination of sources of contamination. Current standardized methods for the differentiation of pectolytic species are time consuming and require trained personnel, as they rely on traditional bacteriological practices that do not always produce conclusive results. In this growing world market, there is a need for rapid diagnostic tests that can differentiate between pectolytic pathogens, as well as separate them from non-pectolytic enteric bacteria associated with soft rots of potato. An assay has been designed previously to detect the temperate pathogen Pectobacterium atrosepticum, but there is currently no recognized rapid assay for the detection of the tropical/subtropical counterpart, Pectobacterium carotovorum. This report describes the development of a loop-mediated isothermal amplification (LAMP) assay that detects P. carotovorum with high specificity. The assay was evaluated using all known species of Pectobacterium and only showed positive reactions for P. carotovorum. This assay was also tested against 15 non-target genera of plant-associated bacteria and did not produce any false positives. The LAMP assay described here can be used as a rapid test for the differentiation of P. carotovorum from other pectolytic pathogens, and its gene target can be the basis for the development of other molecular-based detection assays. © 2016 BSPP and John Wiley & Sons Ltd.

  9. Site-specific fab fragment biotinylation at the conserved nucleotide binding site for enhanced Ebola detection.

    Science.gov (United States)

    Mustafaoglu, Nur; Alves, Nathan J; Bilgicer, Basar

    2015-07-01

    The nucleotide binding site (NBS) is a highly conserved region between the variable light and heavy chains at the Fab domains of all antibodies, and a small molecule that we identified, indole-3-butyric acid (IBA), binds specifically to this site. Fab fragment, with its small size and simple production methods compared to intact antibody, is good candidate for use in miniaturized diagnostic devices and targeted therapeutic applications. However, commonly used modification techniques are not well suited for Fab fragments as they are often more delicate than intact antibodies. Fab fragments are of particular interest for sensor surface functionalization but immobilization results in damage to the antigen binding site and greatly reduced activity due to their truncated size that allows only a small area that can bind to surfaces without impeding antigen binding. In this study, we describe an NBS-UV photocrosslinking functionalization method (UV-NBS(Biotin) in which a Fab fragment is site-specifically biotinylated with an IBA-EG11-Biotin linker via UV energy exposure (1 J/cm(2)) without affecting its antigen binding activity. This study demonstrates successful immobilization of biotinylated Ebola detecting Fab fragment (KZ52 Fab fragment) via the UV-NBS(Biotin) method yielding 1031-fold and 2-fold better antigen detection sensitivity compared to commonly used immobilization methods: direct physical adsorption and NHS-Biotin functionalization, respectively. Utilization of the UV-NBS(Biotin) method for site-specific conjugation to Fab fragment represents a proof of concept use of Fab fragment for various diagnostic and therapeutic applications with numerous fluorescent probes, affinity molecules and peptides. © 2015 Wiley Periodicals, Inc.

  10. Sensitivity and specificity of fluorescence microlymphography for detecting lymphedema of the lower extremity.

    Science.gov (United States)

    Keo, Hong H; Schilling, Marianne; Büchel, Roland; Gröchenig, Ernst; Engelberger, Rolf P; Willenberg, Torsten; Baumgartner, Iris; Gretener, Silvia B

    2013-06-01

    Fluorescence microlymphography (FML) is used to visualize the lymphatic capillaries. A maximum spread of the fluorescence dye of ≥ 12 mm has been suggested for the diagnosis of lymphedema. However, data on sensitivity and specificity are lacking. The aim of this study was to investigate the accuracy of FML for diagnosing lymphedema in patients with leg swelling. Patients with lower extremity swelling were clinically assessed and separated into lymphedema and non-lymphatic edema groups. FML was studied in all affected legs and the maximum spread of lymphatic capillaries was measured. Test accuracy and receiver operator characteristic (ROC) analysis was performed to assess possible threshold values that predict lymphedema. Between March 2008 and August 2011 a total of 171 patients (184 legs) with a median age of 43.5 (IQR 24, 54) years were assessed. Of those, 94 (51.1%) legs were diagnosed with lymphedema. The sensitivity, specificity, positive and negative likelihood ratio and positive and negative predictive value were 87%, 64%, 2.45, 0.20, 72% and 83% for the 12-mm cut-off level and 79%, 83%, 4.72, 0.26, 83% and 79% for the 14-mm cut-off level, respectively. The area under the ROC curve was 0.82 (95% CI: 0.76, 0.88). Sensitivity was higher in the secondary versus primary lymphedema (95.0% vs 74.3%, p = 0.045). No major adverse events were observed. In conclusion, FML is a simple and safe technique for detecting lymphedema in patients with leg swelling. A cut-off level of ≥ 14-mm maximum spread has a high sensitivity and high specificity of detecting lymphedema and should be chosen.

  11. Target-Specific Assay for Rapid and Quantitative Detection of Mycobacterium chimaera DNA.

    Science.gov (United States)

    Zozaya-Valdés, Enrique; Porter, Jessica L; Coventry, John; Fyfe, Janet A M; Carter, Glen P; Gonçalves da Silva, Anders; Schultz, Mark B; Seemann, Torsten; Johnson, Paul D R; Stewardson, Andrew J; Bastian, Ivan; Roberts, Sally A; Howden, Benjamin P; Williamson, Deborah A; Stinear, Timothy P

    2017-06-01

    Mycobacterium chimaera is an opportunistic environmental mycobacterium belonging to the Mycobacterium avium - M. intracellulare complex. Although most commonly associated with pulmonary disease, there has been growing awareness of invasive M. chimaera infections following cardiac surgery. Investigations suggest worldwide spread of a specific M. chimaera clone, associated with contaminated hospital heater-cooler units used during the surgery. Given the global dissemination of this clone, its potential to cause invasive disease, and the laboriousness of current culture-based diagnostic methods, there is a pressing need to develop rapid and accurate diagnostic assays specific for M. chimaera Here, we assessed 354 mycobacterial genome sequences and confirmed that M. chimaera is a phylogenetically coherent group. In silico comparisons indicated six DNA regions present only in M. chimaera We targeted one of these regions and developed a TaqMan quantitative PCR (qPCR) assay for M. chimaera with a detection limit of 100 CFU/ml in whole blood spiked with bacteria. In vitro screening against DNA extracted from 40 other mycobacterial species and 22 bacterial species from 21 diverse genera confirmed the in silico -predicted specificity for M. chimaera Screening 33 water samples from heater-cooler units with this assay highlighted the increased sensitivity of PCR compared to culture, with 15 of 23 culture-negative samples positive by M. chimaera qPCR. We have thus developed a robust molecular assay that can be readily and rapidly deployed to screen clinical and environmental specimens for M. chimaera . Copyright © 2017 American Society for Microbiology.

  12. Highly Specific Detection of Five Exotic Quarantine Plant Viruses using RT-PCR

    Directory of Open Access Journals (Sweden)

    Hoseong Choi

    2013-03-01

    Full Text Available To detect five plant viruses (Beet black scorch virus, Beet necrotic yellow vein virus, Eggplant mottled dwarf virus, Pelargonium zonate spot virus, and Rice yellow mottle virus for quarantine purposes, we designed 15 RT-PCR primer sets. Primer design was based on the nucleotide sequence of the coat protein gene, which is highly conserved within species. All but one primer set successfully amplified the targets, and gradient PCRs indicated that the optimal temperature for the 14 useful primer sets was 51.9°C. Some primer sets worked well regardless of annealing temperature while others required a very specific annealing temperature. A primer specificity test using plant total RNAs and cDNAs of other plant virus-infected samples demonstrated that the designed primer sets were highly specific and generated reproducible results. The newly developed RT-PCR primer sets would be useful for quarantine inspections aimed at preventing the entry of exotic plant viruses into Korea.

  13. Scrambled eggs: A highly sensitive molecular diagnostic workflow for Fasciola species specific detection from faecal samples

    Science.gov (United States)

    Calvani, Nichola Eliza Davies; Windsor, Peter Andrew; Bush, Russell David

    2017-01-01

    Background Fasciolosis, due to Fasciola hepatica and Fasciola gigantica, is a re-emerging zoonotic parasitic disease of worldwide importance. Human and animal infections are commonly diagnosed by the traditional sedimentation and faecal egg-counting technique. However, this technique is time-consuming and prone to sensitivity errors when a large number of samples must be processed or if the operator lacks sufficient experience. Additionally, diagnosis can only be made once the 12-week pre-patent period has passed. Recently, a commercially available coprological antigen ELISA has enabled detection of F. hepatica prior to the completion of the pre-patent period, providing earlier diagnosis and increased throughput, although species differentiation is not possible in areas of parasite sympatry. Real-time PCR offers the combined benefits of highly sensitive species differentiation for medium to large sample sizes. However, no molecular diagnostic workflow currently exists for the identification of Fasciola spp. in faecal samples. Methodology/Principal findings A new molecular diagnostic workflow for the highly-sensitive detection and quantification of Fasciola spp. in faecal samples was developed. The technique involves sedimenting and pelleting the samples prior to DNA isolation in order to concentrate the eggs, followed by disruption by bead-beating in a benchtop homogeniser to ensure access to DNA. Although both the new molecular workflow and the traditional sedimentation technique were sensitive and specific, the new molecular workflow enabled faster sample throughput in medium to large epidemiological studies, and provided the additional benefit of speciation. Further, good correlation (R2 = 0.74–0.76) was observed between the real-time PCR values and the faecal egg count (FEC) using the new molecular workflow for all herds and sampling periods. Finally, no effect of storage in 70% ethanol was detected on sedimentation and DNA isolation outcomes; enabling

  14. Scrambled eggs: A highly sensitive molecular diagnostic workflow for Fasciola species specific detection from faecal samples.

    Directory of Open Access Journals (Sweden)

    Nichola Eliza Davies Calvani

    2017-09-01

    Full Text Available Fasciolosis, due to Fasciola hepatica and Fasciola gigantica, is a re-emerging zoonotic parasitic disease of worldwide importance. Human and animal infections are commonly diagnosed by the traditional sedimentation and faecal egg-counting technique. However, this technique is time-consuming and prone to sensitivity errors when a large number of samples must be processed or if the operator lacks sufficient experience. Additionally, diagnosis can only be made once the 12-week pre-patent period has passed. Recently, a commercially available coprological antigen ELISA has enabled detection of F. hepatica prior to the completion of the pre-patent period, providing earlier diagnosis and increased throughput, although species differentiation is not possible in areas of parasite sympatry. Real-time PCR offers the combined benefits of highly sensitive species differentiation for medium to large sample sizes. However, no molecular diagnostic workflow currently exists for the identification of Fasciola spp. in faecal samples.A new molecular diagnostic workflow for the highly-sensitive detection and quantification of Fasciola spp. in faecal samples was developed. The technique involves sedimenting and pelleting the samples prior to DNA isolation in order to concentrate the eggs, followed by disruption by bead-beating in a benchtop homogeniser to ensure access to DNA. Although both the new molecular workflow and the traditional sedimentation technique were sensitive and specific, the new molecular workflow enabled faster sample throughput in medium to large epidemiological studies, and provided the additional benefit of speciation. Further, good correlation (R2 = 0.74-0.76 was observed between the real-time PCR values and the faecal egg count (FEC using the new molecular workflow for all herds and sampling periods. Finally, no effect of storage in 70% ethanol was detected on sedimentation and DNA isolation outcomes; enabling transport of samples from endemic

  15. Scrambled eggs: A highly sensitive molecular diagnostic workflow for Fasciola species specific detection from faecal samples.

    Science.gov (United States)

    Calvani, Nichola Eliza Davies; Windsor, Peter Andrew; Bush, Russell David; Šlapeta, Jan

    2017-09-01

    Fasciolosis, due to Fasciola hepatica and Fasciola gigantica, is a re-emerging zoonotic parasitic disease of worldwide importance. Human and animal infections are commonly diagnosed by the traditional sedimentation and faecal egg-counting technique. However, this technique is time-consuming and prone to sensitivity errors when a large number of samples must be processed or if the operator lacks sufficient experience. Additionally, diagnosis can only be made once the 12-week pre-patent period has passed. Recently, a commercially available coprological antigen ELISA has enabled detection of F. hepatica prior to the completion of the pre-patent period, providing earlier diagnosis and increased throughput, although species differentiation is not possible in areas of parasite sympatry. Real-time PCR offers the combined benefits of highly sensitive species differentiation for medium to large sample sizes. However, no molecular diagnostic workflow currently exists for the identification of Fasciola spp. in faecal samples. A new molecular diagnostic workflow for the highly-sensitive detection and quantification of Fasciola spp. in faecal samples was developed. The technique involves sedimenting and pelleting the samples prior to DNA isolation in order to concentrate the eggs, followed by disruption by bead-beating in a benchtop homogeniser to ensure access to DNA. Although both the new molecular workflow and the traditional sedimentation technique were sensitive and specific, the new molecular workflow enabled faster sample throughput in medium to large epidemiological studies, and provided the additional benefit of speciation. Further, good correlation (R2 = 0.74-0.76) was observed between the real-time PCR values and the faecal egg count (FEC) using the new molecular workflow for all herds and sampling periods. Finally, no effect of storage in 70% ethanol was detected on sedimentation and DNA isolation outcomes; enabling transport of samples from endemic to non

  16. Tus-Ter-lock immuno-PCR assays for the sensitive detection of tropomyosin-specific IgE antibodies.

    Science.gov (United States)

    Johnston, Elecia B; Kamath, Sandip D; Lopata, Andreas L; Schaeffer, Patrick M

    2014-02-01

    The increasing prevalence of food allergies requires development of specific and sensitive tests capable of identifying the allergen responsible for the disease. The development of serologic tests that can detect specific IgE antibodies to allergenic proteins would, therefore, be highly received. Here we present two new quantitative immuno-PCR assays for the sensitive detection of antibodies specific to the shrimp allergen tropomyosin. Both assays are based on the self-assembling Tus-Ter-lock protein-DNA conjugation system. Significantly elevated levels of tropomyosin-specific IgE were detected in sera from patients allergic to shrimp. This is the first time an allergenic protein has been fused with Tus to enable specific IgE antibody detection in human sera by quantitative immuno-PCR.

  17. Molecularly specific detection of bacterial lipoteichoic acid for diagnosis of prosthetic joint infection of the bone.

    Science.gov (United States)

    Pickett, Julie E; Thompson, John M; Sadowska, Agnieszka; Tkaczyk, Christine; Sellman, Bret R; Minola, Andrea; Corti, Davide; Lanzavecchia, Antonio; Miller, Lloyd S; Thorek, Daniel Lj

    2018-01-01

    Discriminating sterile inflammation from infection, especially in cases of aseptic loosening versus an actual prosthetic joint infection, is challenging and has significant treatment implications. Our goal was to evaluate a novel human monoclonal antibody (mAb) probe directed against the Gram-positive bacterial surface molecule lipoteichoic acid (LTA). Specificity and affinity were assessed in vitro. We then radiolabeled the anti-LTA mAb and evaluated its effectiveness as a diagnostic imaging tool for detecting infection via immunoPET imaging in an in vivo mouse model of prosthetic joint infection (PJI). In vitro and ex vivo binding of the anti-LTA mAb to pathogenic bacteria was measured with Octet, ELISA, and flow cytometry. The in vivo PJI mouse model was assessed using traditional imaging modalities, including positron emission tomography (PET) with [ 18 F]FDG and [ 18 F]NaF as well as X-ray computed tomography (CT), before being evaluated with the zirconium-89-labeled antibody specific for LTA ([ 89 Zr]SAC55). The anti-LTA mAb exhibited specific binding in vitro to LTA-expressing bacteria. Results from imaging showed that our model could reliably simulate infection at the surgical site by bioluminescent imaging, conventional PET tracer imaging, and bone morphological changes by CT. One day following injection of both the radiolabeled anti-LTA and isotype control antibodies, the anti-LTA antibody demonstrated significantly greater ( P  infected prosthesis sites over either the same antibody at sterile prosthesis sites or of control non-specific antibody at infected prosthesis sites. Taken together, the radiolabeled anti-LTA mAb, [ 89 Zr]SAC55, may serve as a valuable diagnostic molecular imaging probe to help distinguish between sterile inflammation and infection in the setting of PJI. Future studies are needed to determine whether these findings will translate to human PJI.

  18. Alpha toxin specific PCR for detection of toxigenic strains of Clostridium perfringens in Poultry

    Directory of Open Access Journals (Sweden)

    Malmarugan Shanmugasamy

    2012-12-01

    Full Text Available Aim : Isolation of clostridium perfirngens from necrotic enteritis cases in poultry and confirmation by alpha toxin specific PCR Materials and methods: Robertson cooked meat medium with Brain Heart Infusion broth was used for isolation of C. perfringens from intestinal contents of necrotic enteritis suspected birds. Positive cultures from perfringens agar were further confirmed by biochemical tests and subjected to alpha toxin specific PCR. Results: Twenty Clostridium perfringens isolates were isolated from intestinal contents of thirty five NE suspected birds. Out of the twenty isolates, fourteen were isolated from commercial broilers of 2 to 6 wk of age and six from commercial layers of 9 to 15 wk of age. Frequency of isolation of C. perfringens was more with Robertson cooked meat medium with BHI broth than thioglycollate broth alone. When positive cultures were streaked on to clostridial agar appreciable luxuriant growths were obtained and the selective streaking of these colonies on perfringens agar with supplements revealed rough and black colonies with sulphate reduction. The isolates produced rough and black colonies with sulphate reduction on perfringens agar, double zone haemolysis on sheep blood agar, stormy clot fermentation on milk medium and opalescence on egg yolk medium. The isolates were found negative for oxidase, catalase, liquefied gelatin, fermented glucose, maltose, lactose and sucrose except mannitol. All the fourteen isolates obtained from commercial broilers proved the alpha toxin producing strains of C. perfringens when they were subjected to alpha toxin specific PCR. Conclusion : This study revealed alpha toxin specific PCR is highly useful for detection of toxigenic strains of Clostridium perfringens in poultry [Vet. World 2012; 5(6.000: 365-368

  19. Detection of Pathogen Exposure in African Buffalo Using Non-Specific Markers of Inflammation

    Directory of Open Access Journals (Sweden)

    Caroline K. Glidden

    2018-01-01

    Full Text Available Detecting exposure to new or emerging pathogens is a critical challenge to protecting human, domestic animal, and wildlife health. Yet, current techniques to detect infections typically target known pathogens of humans or economically important animals. In the face of the current surge in infectious disease emergence, non-specific disease surveillance tools are urgently needed. Tracking common host immune responses indicative of recent infection may have potential as a non-specific diagnostic approach for disease surveillance. The challenge to immunologists is to identify the most promising markers, which ideally should be highly conserved across pathogens and host species, become upregulated rapidly and consistently in response to pathogen invasion, and remain elevated beyond clearance of infection. This study combined an infection experiment and a longitudinal observational study to evaluate the utility of non-specific markers of inflammation [NSMI; two acute phase proteins (haptoglobin and serum amyloid A, two pro-inflammatory cytokines (IFNγ and TNF-α] as indicators of pathogen exposure in a wild mammalian species, African buffalo (Syncerus caffer. Specifically, in the experimental study, we asked (1 How quickly do buffalo mount NSMI responses upon challenge with an endemic pathogen, foot-and-mouth disease virus; (2 for how long do NSMI remain elevated after viral clearance and; (3 how pronounced is the difference between peak NSMI concentration and baseline NSMI concentration? In the longitudinal study, we asked (4 Are elevated NSMI associated with recent exposure to a suite of bacterial and viral respiratory pathogens in a wild population? Among the four NSMI that we tested, haptoglobin showed the strongest potential as a surveillance marker in African buffalo: concentrations quickly and consistently reached high levels in response to experimental infection, remaining elevated for almost a month. Moreover, elevated haptoglobin was

  20. Noise and specific detectivity measurements on high-temperature superconducting transition-edge bolometers

    International Nuclear Information System (INIS)

    Black, R.D.; Mogro-campero, A.; Turner, L.G.

    1990-01-01

    The effects of thermal fluctuation noise in thermal detectors can be lessened by reducing heat capacity and thermal conductance. An attempt to accomplish this with the YBa2Cu3O(7-x) (YBCO) bolometer by making YBCO resistors on thermally isolated membranes is reported. The spectral power of the electrical noise of YBCO films on SrTiO3, bulk silicon with a buffer layer, and in thin dielectric membranes is measured. It is found that 1/f noise predominates in polycrystalline YBCO films on silicon-based substrates. Films on SrTiO3 with good electrical properties are dominated by thermal fluctuation noise, just as in the case of low-temperature superconductors. The implications of these findings for bolometer are addressed. The specific detectivity of a bolometric pixel made on bulk SrTiO3 is reported. 14 refs

  1. Digital lock-in detection of site-specific magnetism in magnetic materials

    Science.gov (United States)

    Haskel, Daniel [Naperville, IL; Lang, Jonathan C [Naperville, IL; Srajer, George [Oak Park, IL

    2008-07-22

    The polarization and diffraction characteristics of x-rays incident upon a magnetic material are manipulated to provide a desired magnetic sensitivity in the material. The contrast in diffracted intensity of opposite helicities of circularly polarized x-rays is measured to permit separation of magnetic signals by element type and by atomic environment. This allows for the direct probing of magnetic signals from elements of the same species in nonequivalent atomic environments to better understand the behavior and characteristics of permanent magnetic materials. By using known crystallographic information together with manipulation of the polarization of x-rays having energies tuned near element-specific electronic excitations and by detecting and comparing the incident and diffracted photons at the same frequency, more accurate magnetic measurements can be made over shorter observation periods.

  2. Specific antibodies to porcine zona pellucida detected by quantitative radioimmunoassay in both fertile and infertile women

    International Nuclear Information System (INIS)

    Kurachi, H.; Wakimoto, H.; Sakumoto, T.; Aono, T.; Kurachi, K.

    1984-01-01

    The specific radioimmunoassay system was developed for the titration of the antibodies to porcine zona pellucida (ZP) in human sera by using 125 I-labeled purified porcine ZP as antigen, which is known to have cross-reactivity with human ZP. The antibodies in human sera were detected in 3 of 11 (27%) women with unexplained infertility, in 16 of 48 (33%) amenorrheic patients, in 4 of 12 (33%) fertile women, and in 3 of 10 (30%) men. Moreover, antibody titers in infertile women were no higher than those in fertile women and in men. These results seem to suggest that the antibodies in human sera that cross-react with porcine ZP may not be an important factor in causing infertility in women

  3. Sensibility and specificity of the stress echocardiography with Dobutamine for the detection of coronary disease

    International Nuclear Information System (INIS)

    Senior, Juan Manuel; Escobar, Carlos Ignacio; Jaramillo, Mario and others

    2001-01-01

    Dobutamine stress echocardiography has become a useful method for detecting coronary artery disease in the high prevalence population. The reported sensitivity varies between 76-90% and the specificity between 60-95%. 60-95% there have been few reports regarding sensitivity and specificity among our population. The aim of this study was to evaluate the sensitivity of dopamine stress echocardiography in a population with a high probability of coronary disease. This was a randomized retrospective-prospective study. Between February 1 of 1998 and February 1 of 1999. 409 patients underwent dopamine stress echocardiography and were analyzed according to established protocol. The Dobutamine stress echocardiography as well as the angiography was checked in a blind form by one of the participating researchers trained in those procedures. The diagnostic concordance was found to be greater than 90%. Significant coronary disease was considered to be present in those cases in which there was severe stenosis greater than 50% in a major epicardial artery or greater than 40 % in the left main artery. Coronary arteriography was performed within three months of Dobutamine stress echocardiography imaging. A sixteen-segment model was used as the index for the evaluation of systolic wall thickening and the results were classified as follows: normal (l), ischemia (ll), fixed abnormality (lll) and mixed (lV). 409 patients with an average age of 62.8 +/- 12) were included in the study at random. Six patients with mediocre technical examinations were excluded. 47 % were male. 29% had a history of myocardial infarction, 35 % had a history of arterial hypertension and 10% had diabetes mellitus. The average ejection fraction was 54 +/- 13%. The examination was prescribed in order to detect the presence of ischemia in 95.8% of the cases and as part of preoperative evaluation in 4.2 %. There were adverse effects in 40% of the cases; 15% of these were systemic and 25 % cardiac. The test was

  4. [A new class of exciplex-formed probe detect of specific sequence DNA].

    Science.gov (United States)

    Li, Qing-Yong; Zu, Yuan-Gang; Lü, Hong-Yan; Wang, Li-Min

    2009-07-01

    The present research was to develop the exciplex-based fluorescence detection of DNA. A SNP-containing region of cytochrome P450 2C9 DNA systems was evaluated to define some of the structural and associated requirement of this new class of exciplex-formed probe, and a 24-base target was selected which contains single-nucleotide polymorphisms (SNP) in genes coding for cytochrome P450. The two probes were all 12-base to give coverage of a 24-base target region to ensure specificity within the human genome. Exciplex partners used in this study were prepared using analogous phosphoramide attachment to the 3'- or 5'-phosphate group of the appropriate oligonucleotide probes. The target effectively assembled its own detector by hybridization from components which were non-fluorescent at the detection wavelength, leading to the huge improvement in terms of decreased background. This research provides details of the effects of different partner, position of partners and different excitation wavelengths for the split-oligonucleotide probe system for exciplex-based fluorescence detection of DNA. This study demonstrates that the emission intensity of the excimer formed by new pyrene derivative is the highest in these excimer and exciplex, and the excimer is easy to be formed and not sensitive to the position of partners. However the exciplex formed by the new pyrene derivative and naphthalene emitted strongly at -505 nm with large Stokes shifts (120-130 nm), and the monomer emission at 390 and 410 nm is nearly zero. Excitation wavelength of 400 nm is the best for I(e505)/I(m410) (exciplex emission at 505 nm/monomer emission at 410 nm) of the exciplex. This method features lower background and high sensitivity. Moreover the exciplex is sensitive to the steric factor, different position of partners and microenvironment, so this exciplex system is promising and could be tried to identify the SNP genes.

  5. Detection of Ophiocordyceps sinensis and Its Common Adulterates Using Species-Specific Primers

    Science.gov (United States)

    Liu, Yang; Wang, Xiao-yue; Gao, Zi-tong; Han, Jian-ping; Xiang, Li

    2017-01-01

    Ophiocordyceps sinensis is a fungus that infects Hepialidae caterpillars, mummifying the larvae and producing characteristic fruiting bodies (stromata) that are processed into one of the most valued traditional Chinese medicines (TCM). The product commands a very high price due to a high demand but a very limited supply. Adulteration with other fungi is a common problem and there is a need to test preparation for the presence of the correct fungus. In the current study, a PCR-based approach for the identification of O. sinensis based on a segment of the internal transcribed spacer (ITS) region was developed. The segments is 146-bp in size and is likely to be amplified even in materials where processing led to DNA fragmentation. Primer development was based on the alignment of sequence data generated from a total of 89 samples of O. sinensis and potential adulterants as well as sequences date from 41 Ophiocordyceps species and 26 Cordyceps species available in GenBank. Tests with primer pair, DCF4/DCR4, demonstrated generation of an amplicon from DNA extracted from O. sinensis stromata, but not from extracts derived from adulterants. Species-specific primer pairs were also developed and tested for detection of the common adulterants, Cordyceps gunnii, Cordyceps cicadae, Cordyceps militaris, Cordyceps liangshanensis and Ophiocordyceps nutans. The collection of primers developed in the present study will be useful for the authentication of preparation claiming to only contain O. sinensis and for the detection of fungi used as adulterants in these preparations. PMID:28680424

  6. Detection of activated platelets using activation-specific monoclonal antibody (SZ-51) in clinical disorders

    International Nuclear Information System (INIS)

    Wu Guoxin; Li Fugang; Li Jianyong; Ruan Changgeng

    1991-10-01

    A direct test for activated platelets in whole blood was developed by radioimmunoassay with 125 I labeled SZ-51, an antibody specific for an α-granule membrane protein (GMP-140) that associates with the platelet surface during secretion. The assay had sufficient sensitivity to detect as few as 2% activated platelets. In 50 normal subjects, minimal GMP-140 molecules per platelet were expressed on the surface of circulating platelets. Ten patients undergoing cardiopulmonary bypass had transiently increased expression of GMP-140 molecules during the bypass procedure, especially at the end of bypass. Evaluation of 18 patients with epidemic hemorrhagic fever (EHF) has shown that the number of GMP-140 molecules on the platelet surface was closely related to the four different phases of EHF. In six patients suffered from acute myocardial infarction (AMI), the number of GMP-140 molecules changed with the procession of AMI and the highest occurred 48 h after AMI. The GMP-140 molecules were also increased in patients with asthma attack (n = 14), but not in patients with idiopathic thrombocytopenic purpura (n = 11) and diabetic mellitus (n = 48). Taken together, these studies suggest that activated platelet can be reliably measured in whole blood using radiolabeled SZ-51 antibody and the detection of activated platelets is potentially useful in identifying patients with certain thrombotic disorders and others

  7. Specific and sensitive primers for the detection of predated olive fruit flies, Bactrocera oleae (Diptera: Tephritidae

    Directory of Open Access Journals (Sweden)

    Esther Lantero

    2017-07-01

    Full Text Available Bactrocera oleae, the olive fruit fly, is a major pest of olive (Olea europaea L. trees worldwide. Its presence can cause important losses, with consequences for the economies of countries that produce and export table olives and olive oil. Efforts to control olive fruit fly populations have, however, been insufficient. Now more than ever, environmentally friendly alternatives need to be considered in potential control programs. Generalist predators could provide a way of managing this pest naturally. However, the identification of candidate predator species is essential if such a management system is to be introduced. The present paper describes a set of species-specific primers for detecting the presence of B. oleae DNA in the gut of predatory arthropods. All primers were tested for checking cross-reactive amplification of other fruit fly DNA and evaluated in heterospecific mixes of nucleic acids. All were found to be very sensitive for B. oleae. Subsequent feeding trials were conducted using one of the most abundant species of ground dwelling carabids in olive groves in south-eastern Madrid, Spain. These trials allowed determining that 253F-334R and 334F-253R primer pairs had the highest detection efficiency with an ID50 of around 78 h. These primers therefore provide a very useful tool for screening the gut contents of potential predators of B. oleae, and can thus reveal candidate species for the pest's biological control

  8. Specific and sensitive primers for the detection of predated olive fruit flies, Bactrocera oleae (Diptera: Tephritidae)

    Energy Technology Data Exchange (ETDEWEB)

    Lantero, E.; Matallanas, B.; Ochando, M.D.; Pascual, S.; Callejas, C.

    2017-07-01

    Bactrocera oleae, the olive fruit fly, is a major pest of olive (Olea europaea L.) trees worldwide. Its presence can cause important losses, with consequences for the economies of countries that produce and export table olives and olive oil. Efforts to control olive fruit fly populations have, however, been insufficient. Now more than ever, environmentally friendly alternatives need to be considered in potential control programs. Generalist predators could provide a way of managing this pest naturally. However, the identification of candidate predator species is essential if such a management system is to be introduced. The present paper describes a set of species-specific primers for detecting the presence of B. oleae DNA in the gut of predatory arthropods. All primers were tested for checking cross-reactive amplification of other fruit fly DNA and evaluated in heterospecific mixes of nucleic acids. All were found to be very sensitive for B. oleae. Subsequent feeding trials were conducted using one of the most abundant species of ground dwelling carabids in olive groves in south-eastern Madrid, Spain. These trials allowed determining that 253F-334R and 334F-253R primer pairs had the highest detection efficiency with an ID50 of around 78 h. These primers therefore provide a very useful tool for screening the gut contents of potential predators of B. oleae, and can thus reveal candidate species for the pest's biological control.

  9. Specific and sensitive primers for the detection of predated olive fruit flies, Bactrocera oleae (Diptera: Tephritidae)

    International Nuclear Information System (INIS)

    Lantero, E.; Matallanas, B.; Ochando, M.D.; Pascual, S.; Callejas, C.

    2017-01-01

    Bactrocera oleae, the olive fruit fly, is a major pest of olive (Olea europaea L.) trees worldwide. Its presence can cause important losses, with consequences for the economies of countries that produce and export table olives and olive oil. Efforts to control olive fruit fly populations have, however, been insufficient. Now more than ever, environmentally friendly alternatives need to be considered in potential control programs. Generalist predators could provide a way of managing this pest naturally. However, the identification of candidate predator species is essential if such a management system is to be introduced. The present paper describes a set of species-specific primers for detecting the presence of B. oleae DNA in the gut of predatory arthropods. All primers were tested for checking cross-reactive amplification of other fruit fly DNA and evaluated in heterospecific mixes of nucleic acids. All were found to be very sensitive for B. oleae. Subsequent feeding trials were conducted using one of the most abundant species of ground dwelling carabids in olive groves in south-eastern Madrid, Spain. These trials allowed determining that 253F-334R and 334F-253R primer pairs had the highest detection efficiency with an ID50 of around 78 h. These primers therefore provide a very useful tool for screening the gut contents of potential predators of B. oleae, and can thus reveal candidate species for the pest's biological control.

  10. Human cryptosporidiosis: detection of specific antibodies in the serum by an indirect immunofluorescence

    Directory of Open Access Journals (Sweden)

    Braz Lúcia M.A.

    1996-01-01

    Full Text Available Cryptosporidium sp., a coccidian parasite usually found in the faeces of cattle, has been recently implicated as an agent of human intestinal disease, mainly in immunocompromised patients. In the study realized, by an indirect immunofluorescence technique, specific immunoglobulins (IgG and IgM have been demonstrated in human serum against Cryptosporidium oocysts. Purified oocysts were used as antigens in the indirect immunofluorecence assay. After analyzing this test in sera from selected groups of patients, the frequency of both specific IgG and IgM of immunocompetent children who were excreting oocysts in their faeces was 62% and in children with negative excretion of oocysts was 20% and 40%, respectively. In adults infected with the human immunodeficiency virus (HIV and who were excreting Cryptosporidium in their stools, the frequency was 57% for IgG but only 2% for IgM. Twenty three percent of immunocompromised adults with not determined excretion of oocysts in their stools had anti-Cryptosporidium IgG in their sera. Children infected with human immunodeficiency virus had no IgM and only 14% had IgG detectable in their sera. The indirect immunoflorescence assay, when used with other parasitological techniques appears to be useful for retrospective population studies and for diagnosis of acute infection. The humoral immune response of HIV positive patients to this protozoan agent needs clarification.

  11. Specific detection of oxytetracycline using DNA aptamer-immobilized interdigitated array electrode chip

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeon Seok; Niazi, Javed H [School of Life Sciences and Biotechnology, Korea University, Anam-dong, Seongbuk-gu, Seoul 136-701 (Korea, Republic of); Gu, Man Bock [School of Life Sciences and Biotechnology, Korea University, Anam-dong, Seongbuk-gu, Seoul 136-701 (Korea, Republic of)], E-mail: mbgu@korea.ac.kr

    2009-02-23

    An electrochemical sensing system for oxytetracycline (OTC) detection was developed using ssDNA aptamer immobilized on gold interdigitated array (IDA) electrode chip. A highly specific ssDNA aptamer that bind to OTC with high affinity was employed to discriminate other tetracyclines (TCs), such as doxycycline (DOX) and tetracycline (TET). The immobilized thiol-modified aptamer on gold electrode chip served as a biorecognition element for the target molecules and the electrochemical signals generated from interactions between the aptamers and the target molecules was evaluated by cyclic voltammetry (CV) and square wave voltammetry (SWV). The current decrease due to the interference of bound OTC, DOX or TET was analyzed with the electron flow produced by a redox reaction between ferro- and ferricyanide. The specificity of developed EC-biosensor for OTC was highly distinguishable from the structurally similar antibiotics (DOX and TET). The dynamic range was determined to be 1-100 nM of OTC concentration in semi-logarithmic coordinates.

  12. Specific detection of oxytetracycline using DNA aptamer-immobilized interdigitated array electrode chip

    International Nuclear Information System (INIS)

    Kim, Yeon Seok; Niazi, Javed H.; Gu, Man Bock

    2009-01-01

    An electrochemical sensing system for oxytetracycline (OTC) detection was developed using ssDNA aptamer immobilized on gold interdigitated array (IDA) electrode chip. A highly specific ssDNA aptamer that bind to OTC with high affinity was employed to discriminate other tetracyclines (TCs), such as doxycycline (DOX) and tetracycline (TET). The immobilized thiol-modified aptamer on gold electrode chip served as a biorecognition element for the target molecules and the electrochemical signals generated from interactions between the aptamers and the target molecules was evaluated by cyclic voltammetry (CV) and square wave voltammetry (SWV). The current decrease due to the interference of bound OTC, DOX or TET was analyzed with the electron flow produced by a redox reaction between ferro- and ferricyanide. The specificity of developed EC-biosensor for OTC was highly distinguishable from the structurally similar antibiotics (DOX and TET). The dynamic range was determined to be 1-100 nM of OTC concentration in semi-logarithmic coordinates

  13. Workshop summary: detection, impact, and control of specific pathogens in animal resource facilities.

    Science.gov (United States)

    Mansfield, Keith G; Riley, Lela K; Kent, Michael L

    2010-01-01

    Despite advances, infectious diseases remain a threat to animal facilities, continue to affect animal health, and serve as potential confounders of experimental research. A workshop entitled Detection, Impact, and Control of Specific Pathogens in Animal Resource Facilities was sponsored by the National Center for Research Resources (NCRR) and National Institutes of Aging (NIA) and held April 23-24, 2009, at the Lister Hill Conference Center on the National Institutes of Health's (NIH) Bethesda campus. The meeting brought together laboratory animal scientists and veterinarians with experience in fish, rodent, and nonhuman primate models to identify common issues and problems. Session speakers addressed (1) common practices and current knowledge of these species, (2) new technologies in the diagnosis of infectious diseases, (3) impact of environmental quality on infectious disease, (4) normal microbial flora in health and disease, (5) genetics and infectious disease, and (6) specific infectious agents and their impact on research. Attendees discussed current challenges and future needs, highlighting the importance of education and training, the funding of critical infrastructure and resource research, and the need for improved communication of disease risks and integration of these risks with strategic planning. NIH and NCRR have a strong record of supporting resource initiatives that have helped address many of these issues and recent efforts have focused on the building of consortium activities among such programs. This manuscript summarizes the presentations and conclusions of participants at the meeting; abstracts and a full conference report are available online (www.ncrr.nih.gov).

  14. Large-scale detection of antigen-specific T cells using peptide-MHC-I multimers labeled with DNA barcodes

    DEFF Research Database (Denmark)

    Bentzen, Amalie Kai; Marquard, Andrea Marion; Lyngaa, Rikke Birgitte

    2016-01-01

    -major histocompatibility complex (MHC) multimers labeled with individual DNA barcodes to screen >1,000 peptide specificities in a single sample, and detect low-frequency CD8 T cells specific for virus- or cancer-restricted antigens. When analyzing T-cell recognition of shared melanoma antigens before and after adoptive...... cell therapy in melanoma patients, we observe a greater number of melanoma-specific T-cell populations compared with cytometry-based approaches. Furthermore, we detect neoepitope-specific T cells in tumor-infiltrating lymphocytes and peripheral blood from patients with non-small cell lung cancer...

  15. Highly sensitive real-time PCR for specific detection and quantification of Coxiella burnetii

    Directory of Open Access Journals (Sweden)

    Linke Sonja

    2006-01-01

    Full Text Available Abstract Background Coxiella burnetii, the bacterium causing Q fever, is an obligate intracellular biosafety level 3 agent. Detection and quantification of these bacteria with conventional methods is time consuming and dangerous. During the last years, several PCR based diagnostic assays were developed to detect C. burnetii DNA in cell cultures and clinical samples. We developed and evaluated TaqMan-based real-time PCR assays that targeted the singular icd (isocitrate dehydrogenase gene and the transposase of the IS1111a element present in multiple copies in the C. burnetii genome. Results To evaluate the precision of the icd and IS1111 real-time PCR assays, we performed different PCR runs with independent DNA dilutions of the C. burnetii Nine Mile RSA493 strain. The results showed very low variability, indicating efficient reproducibility of both assays. Using probit analysis, we determined that the minimal number of genome equivalents per reaction that could be detected with a 95% probability was 10 for the icd marker and 6.5 for the IS marker. Plasmid standards with cloned icd and IS1111 fragments were used to establish standard curves which were linear over a range from 10 to 107 starting plasmid copy numbers. We were able to quantify cell numbers of a diluted, heat-inactivated Coxiella isolate with a detection limit of 17 C. burnetii particles per reaction. Real-time PCR targeting both markers was performed with DNA of 75 different C. burnetii isolates originating from all over the world. Using this approach, the number of IS1111 elements in the genome of the Nine Mile strain was determined to be 23, close to 20, the number revealed by genome sequencing. In other isolates, the number of IS1111 elements varied widely (between seven and 110 and seemed to be very high in some isolates. Conclusion We validated TaqMan-based real-time PCR assays targeting the icd and IS1111 markers of C. burnetii. The assays were shown to be specific, highly

  16. Detection of prostate cancer-specific transcripts in extracellular vesicles isolated from post-DRE urine.

    Science.gov (United States)

    Pellegrini, Kathryn L; Patil, Dattatraya; Douglas, Kristen J S; Lee, Grace; Wehrmeyer, Kathryn; Torlak, Mersiha; Clark, Jeremy; Cooper, Colin S; Moreno, Carlos S; Sanda, Martin G

    2017-06-01

    The measurement of gene expression in post-digital rectal examination (DRE) urine specimens provides a non-invasive method to determine a patient's risk of prostate cancer. Many currently available assays use whole urine or cell pellets for the analysis of prostate cancer-associated genes, although the use of extracellular vesicles (EVs) has also recently been of interest. We investigated the expression of prostate-, kidney-, and bladder-specific transcripts and known prostate cancer biomarkers in urine EVs. Cell pellets and EVs were recovered from post-DRE urine specimens, with the total RNA yield and quality determined by Bioanalyzer. The levels of prostate, kidney, and bladder-associated transcripts in EVs were assessed by TaqMan qPCR and targeted sequencing. RNA was more consistently recovered from the urine EV specimens, with over 80% of the patients demonstrating higher RNA yields in the EV fraction as compared to urine cell pellets. The median EV RNA yield of 36.4 ng was significantly higher than the median urine cell pellet RNA yield of 4.8 ng. Analysis of the post-DRE urine EVs indicated that prostate-specific transcripts were more abundant than kidney- or bladder-specific transcripts. Additionally, patients with prostate cancer had significantly higher levels of the prostate cancer-associated genes PCA3 and ERG. Post-DRE urine EVs are a viable source of prostate-derived RNAs for biomarker discovery and prostate cancer status can be distinguished from analysis of these specimens. Continued analysis of urine EVs offers the potential discovery of novel biomarkers for pre-biopsy prostate cancer detection. © 2017 Wiley Periodicals, Inc.

  17. Specific Physician Orders Improve Pain Detection and Pain Reports in Nursing Home Residents: Preliminary Data.

    Science.gov (United States)

    Monroe, Todd B; Misra, Sumathi; Habermann, Ralf C; Dietrich, Mary S; Bruehl, Stephen P; Cowan, Ronald L; Newhouse, Paul A; Simmons, Sandra F

    2015-10-01

    Despite evidence that many nursing home residents' pain is poorly managed, reasons for this poor management remain unanswered. The aim of this study was to determine if specific order sets related to pain assessment would improve pain management in nursing home (NH) residents. Outcomes included observed nurse pain assessment queries and resident reports of pain. The pretest/post-test study was performed in a 240-bed for-profit nursing home in the mid-southern region of the United States and participants were 43 nursing home residents capable of self-consent. Medical chart abstraction was performed during a 2-week (14-day) period before the implementation of specific order sets for pain assessment (intervention) and a 2-week (14-day) period after the intervention. Trained research assistants observed medication administration passes and performed participant interviews after each medication pass. One month after intervention implementation, 1 additional day of observations was conducted to determine data reliability. Nurses were observed to ask residents about pain more frequently, and nurses continued to ask about pain at higher rates 1 month after the intervention was discontinued. The proportion of residents who reported pain also significantly increased in response to increased nurse queries (e.g., "Do you have any pain right now?"), which underscores the importance of nurses directly asking residents about pain. Notably 70% of this long-stay NH population only told the nurses about their pain symptoms when asked directly. Findings uncover that using specific pain order sets seems to improve the detection of pain, which should be a routine part of nursing assessment. Copyright © 2015 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.

  18. Improvement of Prostate Cancer Diagnosis by Detecting PSA Glycosylation-Specific Changes.

    Science.gov (United States)

    Llop, Esther; Ferrer-Batallé, Montserrat; Barrabés, Sílvia; Guerrero, Pedro Enrique; Ramírez, Manel; Saldova, Radka; Rudd, Pauline M; Aleixandre, Rosa N; Comet, Josep; de Llorens, Rafael; Peracaula, Rosa

    2016-01-01

    New markers based on PSA isoforms have recently been developed to improve prostate cancer (PCa) diagnosis. However, novel approaches are still required to differentiate aggressive from non-aggressive PCa to improve decision making for patients. PSA glycoforms have been shown to be differentially expressed in PCa. In particular, changes in the extent of core fucosylation and sialylation of PSA N-glycans in PCa patients compared to healthy controls or BPH patients have been reported. The objective of this study was to determine these specific glycan structures in serum PSA to analyze their potential value as markers for discriminating between BPH and PCa of different aggressiveness. In the present work, we have established two methodologies to analyze the core fucosylation and the sialic acid linkage of PSA N-glycans in serum samples from BPH (29) and PCa (44) patients with different degrees of aggressiveness. We detected a significant decrease in the core fucose and an increase in the α2,3-sialic acid percentage of PSA in high-risk PCa that differentiated BPH and low-risk PCa from high-risk PCa patients. In particular, a cut-off value of 0.86 of the PSA core fucose ratio, could distinguish high-risk PCa patients from BPH with 90% sensitivity and 95% specificity, with an AUC of 0.94. In the case of the α2,3-sialic acid percentage of PSA, the cut-off value of 30% discriminated between high-risk PCa and the group of BPH, low-, and intermediate-risk PCa with a sensitivity and specificity of 85.7% and 95.5%, respectively, with an AUC of 0.97. The latter marker exhibited high performance in differentiating between aggressive and non-aggressive PCa and has the potential for translational application in the clinic.

  19. Evaluation of molecular markers for Phytophthora ramorum detection and identification: Testing for specificity using a standardized library of isolates

    Science.gov (United States)

    F.N. Martin; M.D. Coffey; K. Zeller; R.C. Hamelin; P. Tooley; M. Garbelotto; K.J.D. Hughes; T. Kubisiak; G.J. Bilodeau; L. Levy; C. Blomquist; P.H. Berger

    2009-01-01

    Given the importance of Phytophthora ramorum from a regulatory standpoint, it is imperative that molecular markers for pathogen detection are fully tested to evaluate their specificity in detection of the pathogen. In an effort to evaluate 11 reported diagnostic techniques, we assembled a standardized DNA library using accessions from the World...

  20. Development of a sensitive Luminex xMAP-based microsphere immunoassay for specific detection of Iris yellow spot virus.

    Science.gov (United States)

    Yu, Cui; Yang, Cuiyun; Song, Shaoyi; Yu, Zixiang; Zhou, Xueping; Wu, Jianxiang

    2018-04-04

    Iris yellow spot virus (IYSV) is an Orthotospovirus that infects most Allium species. Very few approaches for specific detection of IYSV from infected plants are available to date. We report the development of a high-sensitive Luminex xMAP-based microsphere immunoassay (MIA) for specific detection of IYSV. The nucleocapsid (N) gene of IYSV was cloned and expressed in Escherichia coli to produce the His-tagged recombinant N protein. A panel of monoclonal antibodies (MAbs) against IYSV was generated by immunizing the mice with recombinant N protein. Five specific MAbs (16D9, 11C6, 7F4, 12C10, and 14H12) were identified and used for developing the Luminex xMAP-based MIA systems along with a polyclonal antibody against IYSV. Comparative analyses of their sensitivity and specificity in detecting IYSV from infected tobacco leaves identified 7F4 as the best-performed MAb in MIA. We then optimized the working conditions of Luminex xMAP-based MIA in specific detection of IYSV from infected tobacco leaves by using appropriate blocking buffer and proper concentration of biotin-labeled antibodies as well as the suitable ratio between the antibodies and the streptavidin R-phycoerythrin (SA-RPE). Under the optimized conditions the Luminex xMAP-based MIA was able to specifically detect IYSV with much higher sensitivity than conventional enzyme-linked immunosorbent assay (ELISA). Importantly, the Luminex xMAP-based MIA is time-saving and the whole procedure could be completed within 2.5 h. We generated five specific MAbs against IYSV and developed the Luminex xMAP-based MIA method for specific detection of IYSV in plants. This assay provides a sensitive, high-specific, easy to perform and likely cost-effective approach for IYSV detection from infected plants, implicating potential broad usefulness of MIA in plant virus diagnosis.

  1. Rapid, highly sensitive and highly specific gene detection by combining enzymatic amplification and DNA chip detection simultaneously

    Directory of Open Access Journals (Sweden)

    Koji Hashimoto

    2016-05-01

    Full Text Available We have developed a novel gene detection method based on the loop-mediated isothermal amplification (LAMP reaction and the DNA dissociation reaction on the same DNA chip surface to achieve a lower detection limit, broader dynamic range and faster detection time than are attainable with a conventional DNA chip. Both FAM- and thiol-labeled DNA probe bound to the complementary sequence accompanying Dabcyl was immobilized on the gold surface via Au/thiol bond. The LAMP reaction was carried out on the DNA probe fixed gold surface. At first, Dabcyl molecules quenched the FAM fluorescence. According to the LAMP reaction, the complementary sequence with Dabcyl was competitively reacted with the amplified targeted sequence. As a result, the FAM fluorescence increased owing to dissociation of the complementary sequence from the DNA probe. The simultaneous reaction of LAMP and DNA chip detection was achieved, and 103 copies of the targeted gene were detected within an hour by measuring fluorescence intensity of the DNA probe. Keywords: Biosensor, DNA chip, Loop-mediated isothermal amplification (LAMP, Fluorescence detection, Gold substrate, Au/thiol bond

  2. Application of photostable quantum dots for indirect immunofluorescent detection of specific bacterial serotypes on small marine animals

    International Nuclear Information System (INIS)

    Decho, Alan W; Beckman, Erin M; Chandler, G Thomas; Kawaguchi, Tomohiro

    2008-01-01

    An indirect immunofluorescence approach was developed using semiconductor quantum dot nanocrystals to label and detect a specific bacterial serotype of the bacterial human pathogen Vibrio parahaemolyticus, attached to small marine animals (i.e. benthic harpacticoid copepods), which are suspected pathogen carriers. This photostable labeling method using nanotechnology will potentially allow specific serotypes of other bacterial pathogens to be detected with high sensitivity in a range of systems, and can be easily applied for sensitive detection to other Vibrio species such as Vibrio cholerae

  3. Detection of Leptospira DNA in urine and presence of specific antibodies in outdoor cats in Germany.

    Science.gov (United States)

    Weis, Sonia; Rettinger, Anna; Bergmann, Michele; Llewellyn, Julia R; Pantchev, Nikola; Straubinger, Reinhard K; Hartmann, Katrin

    2017-04-01

    Objectives Clinical manifestation of infection with Leptospira species in cats is rare. Nevertheless, cats can develop specific antibodies against the spirochetes after infection. In Canada, Taiwan and the USA it was recently demonstrated that naturally infected cats can also shed DNA from pathogenic Leptospira species in their urine, but the zoonotic potential of infected cats is still unclear. The objective of this study was to demonstrate if outdoor cats in Germany shed DNA from pathogenic Leptospira species in their urine. As a second aim, antibody prevalence was determined. Methods Two hundred and fifteen outdoor cats were prospectively recruited. Urine samples were tested by real-time PCR targeting the lipL32 gene of pathogenic Leptospira species. Antibody titres against eight serovars (Australis, Autumnalis, Bratislava, Canicola, Copenhageni, Grippotyphosa, Pomona, Saxkoebing) belonging to seven serogroups (Australis, Autumnalis, Canicola, Grippotyphosa, Icterohaemorrhagiae, Pomona, Sejroe) were determined by microscopic agglutination test. Results Urine samples from 7/215 cats (3.3%; 95% confidence interval [CI] 0.9-5.7) were PCR-positive. Specific antibodies were detected in 35/195 cats (17.9%; 95% CI: 12.5-23.3) with titres ranging from 1:100 to 1:6400. Australis, Bratislava and Grippotyphosa were the most common serovars. Conclusions and relevance Outdoor cats in Germany can shed DNA from pathogenic Leptospira species. Therefore, outdoor cats should be considered as a possible source of infection for dogs or humans. Further studies are needed to determine the role of Leptospira species as a cause of disease in cats.

  4. Farm-specific economic value of automatic lameness detection systems in dairy cattle: From concepts to operational simulations.

    Science.gov (United States)

    Van De Gucht, Tim; Saeys, Wouter; Van Meensel, Jef; Van Nuffel, Annelies; Vangeyte, Jurgen; Lauwers, Ludwig

    2018-01-01

    Although prototypes of automatic lameness detection systems for dairy cattle exist, information about their economic value is lacking. In this paper, a conceptual and operational framework for simulating the farm-specific economic value of automatic lameness detection systems was developed and tested on 4 system types: walkover pressure plates, walkover pressure mats, camera systems, and accelerometers. The conceptual framework maps essential factors that determine economic value (e.g., lameness prevalence, incidence and duration, lameness costs, detection performance, and their relationships). The operational simulation model links treatment costs and avoided losses with detection results and farm-specific information, such as herd size and lameness status. Results show that detection performance, herd size, discount rate, and system lifespan have a large influence on economic value. In addition, lameness prevalence influences the economic value, stressing the importance of an adequate prior estimation of the on-farm prevalence. The simulations provide first estimates for the upper limits for purchase prices of automatic detection systems. The framework allowed for identification of knowledge gaps obstructing more accurate economic value estimation. These include insights in cost reductions due to early detection and treatment, and links between specific lameness causes and their related losses. Because this model provides insight in the trade-offs between automatic detection systems' performance and investment price, it is a valuable tool to guide future research and developments. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Isoschizomers and amplified fragment length polymorphism for the detection of specific cytosine methylation changes.

    Science.gov (United States)

    Ruiz-García, Leonor; Cabezas, Jose Antonio; de María, Nuria; Cervera, María-Teresa

    2010-01-01

    Different molecular techniques have been developed to study either the global level of methylated cytosines or methylation at specific gene sequences. One of them is a modification of the Amplified Fragment Length Polymorphism (AFLP) technique that has been used to study methylation of anonymous CCGG sequences in different fungi, plant and animal species. The main variation of this technique is based on the use of isoschizomers with different methylation sensitivity (such as HpaII and MspI) as a frequent cutter restriction enzyme. For each sample, AFLP analysis is performed using both EcoRI/HpaII and EcoRI/MspI digested samples. Comparative analysis between EcoRI/HpaII and EcoRI/MspI fragment patterns allows the identification of two types of polymorphisms: (1) "Methylation-insensitive polymorphisms" that show common EcoRI/HpaII and EcoRI/MspI patterns but are detected as polymorphic amplified fragments among samples; and (2) "Methylation-sensitive polymorphisms" that are associated with amplified fragments differing in their presence or absence or in their intensity between EcoRI/HpaII and EcoRI/MspI patterns. This chapter describes a detailed protocol of this technique and discusses modifications that can be applied to adjust the technology to different species of interest.

  6. Seizure pattern-specific epileptic epoch detection in patients with intellectual disability

    NARCIS (Netherlands)

    Wang, L.; Arends, J.B.A.M.; Long, X.; Cluitmans, P.J.M.; van Dijk, J.P.

    Electroencephalogram (EEG) features are crucial for the seizure detection performance. Traditional algorithms are designed for a population with normal brain development. However, for patients with an intellectual disability the seizure detection performance is still largely unknown. In addition,

  7. The value of urine specific gravity in detecting diabetes insipidus in a patient with uncontrolled diabetes mellitus: urine specific gravity in differential diagnosis.

    Science.gov (United States)

    Akarsu, Ersin; Buyukhatipoglu, Hakan; Aktaran, Sebnem; Geyik, Ramazan

    2006-11-01

    When a patient with diabetes mellitus presents with worsening polyuria and polydipsia, what is a sensible, cost-effective approach? We report the unique coincidence of type 2 diabetes mellitus and diabetes insipidus. A 46-year-old woman with poorly controlled type 2 diabetes complained of polyuria with a daily output of 5 L. Although urinalysis demonstrated significant glucosuria, diabetes insipidus was suspected owing to a low urine specific gravity (1.008). The low specific gravity persisted during a water deprivation test. Ultimately, diabetes insipidus was confirmed when urine specific gravity and urine osmolality normalized following desmopressin administration. This case emphasizes the importance of accurately interpreting the urine specific gravity in patients with polyuria and diabetes mellitus to detect diabetes insipidus.

  8. Registration for Optical Multimodal Remote Sensing Images Based on FAST Detection, Window Selection, and Histogram Specification

    Directory of Open Access Journals (Sweden)

    Xiaoyang Zhao

    2018-04-01

    Full Text Available In recent years, digital frame cameras have been increasingly used for remote sensing applications. However, it is always a challenge to align or register images captured with different cameras or different imaging sensor units. In this research, a novel registration method was proposed. Coarse registration was first applied to approximately align the sensed and reference images. Window selection was then used to reduce the search space and a histogram specification was applied to optimize the grayscale similarity between the images. After comparisons with other commonly-used detectors, the fast corner detector, FAST (Features from Accelerated Segment Test, was selected to extract the feature points. The matching point pairs were then detected between the images, the outliers were eliminated, and geometric transformation was performed. The appropriate window size was searched and set to one-tenth of the image width. The images that were acquired by a two-camera system, a camera with five imaging sensors, and a camera with replaceable filters mounted on a manned aircraft, an unmanned aerial vehicle, and a ground-based platform, respectively, were used to evaluate the performance of the proposed method. The image analysis results showed that, through the appropriate window selection and histogram specification, the number of correctly matched point pairs had increased by 11.30 times, and that the correct matching rate had increased by 36%, compared with the results based on FAST alone. The root mean square error (RMSE in the x and y directions was generally within 0.5 pixels. In comparison with the binary robust invariant scalable keypoints (BRISK, curvature scale space (CSS, Harris, speed up robust features (SURF, and commercial software ERDAS and ENVI, this method resulted in larger numbers of correct matching pairs and smaller, more consistent RMSE. Furthermore, it was not necessary to choose any tie control points manually before registration

  9. Diagnostic Value of ELISA Tests for the Detection of Specific Antibodies in Cats and Rabbits with Dermatophytosis

    Directory of Open Access Journals (Sweden)

    Marinka Drobnič-Košorok

    2002-01-01

    Full Text Available Two indirect ELISA tests developed for the detection of specific IgG in cats and rabbits, infected with M. canis and T. mentagrophytes, respectively, were evaluated and compared. The levels of specific antibodies were determined in sera of 20 cats and 25 rabbits naturally infected with M. canis and T. mentagrophytes, respectively. Infection was confirmed by the results of fungal culture. Blood samples from 12 cats and 17 rabbits, previously unexposed to dermatophytes, served as negative controls. A significant increase in the level of specific antibodies in groups of infected animals was demonstrated. Sensitivity, specificity and predictive values of a positive and a negative test were determined to evaluate the diagnostic potential. ELISA for the detection of specific antibodies in cats infected with M. canis (ELISA-cats test exhibited 75.0 % of sensitivity at 91.7 % of specificity, whereas the test for the detection of specific antibodies in rabbits, infected with T. mentagrophytes (ELISA-rabbits test is highly sensitive (96.0 % and highly specific (94.1 %, confirming its encouraging diagnostic potential. The cross-reactivity of fungal antigens was tested by performing the assays with antigens M. canis, T. mentagrophytes, M. pachydermatis and A. fumigatus. There were no significant indications of cross-reactions in the test T. mentagrophytes-rabbits, whereas strong cross-reaction between dermatophyte antigens was observed in the test M. canis-cats.

  10. Synthesis and characterization of rare earth molybdates nanoparticles for detection of specific prostatic cancer (PSA)

    International Nuclear Information System (INIS)

    Dias, Clarissa Lombardi

    2013-01-01

    The interest in using rare earths to investigate the properties and functions of biochemical systems as well as to determinate biological substances has increased in several fields, including biomarkers in immunology (fluoro immunoassays). Nowadays the use of lanthanides in the diagnosis of various diseases have become more important through the development of commercial diagnostic kits. As main feature, these rare earths can show a long lifetime, photo stability and emission bands of atomic like behavior and well defined, in the visible region, demonstrating unique advantages when compared to other luminescent species. The present work had as its goal to synthesize rare earth molybdates by the co-precipitation method as well as to characterize these materials by X-ray diffraction, near infrared spectroscopy, thermogravimetric analysis, scanning electronic microscopy, transmission electronic microscopy and luminescent studies. In this work, three different studied were developed: the influence of the vortex speed variation during co-precipitation in the structure of the final product, morphology and luminescence properties; the influence of the annealing temperature also in the structure, morphology and luminescence properties; and the influence of concentration of the doping in the luminescence properties. Another important step of this work was the functionalization of nanoparticles using an organosilane (APTES) to coat and establish points for binding the particles to biological species. It was proved that this process was very efficient by the characterization results and the silica incorporation was well succeeded. Specific prostatic cancer (PSA) was then linked to the functionalized nanoparticles to diagnostic prostatic cancer by fluoroimmunoassay and levels for detection were established. (author)

  11. Molecular characterization and specific detection of Anaplasma species (AP-sd) in sika deer and its first detection in wild brown bears and rodents in Hokkaido, Japan.

    Science.gov (United States)

    Moustafa, Mohamed Abdallah Mohamed; Lee, Kyunglee; Taylor, Kyle; Nakao, Ryo; Sashika, Mariko; Shimozuru, Michito; Tsubota, Toshio

    2015-12-01

    A previously undescribed Anaplasma species (herein referred to as AP-sd) has been detected in sika deer, cattle and ticks in Japan. Despite being highly similar to some strains of A. phagocytophilum, AP-sd has never been detected in humans. Its ambiguous epidemiology and the lack of tools for its specific detection make it difficult to understand and interpret the prevalence of this Anaplasma species. We developed a method for specific detection, and examined AP-sd prevalence in Hokkaido wildlife. Our study included 250 sika deer (Cervus nippon yesoensis), 13 brown bears (Ursus arctos yesoensis) and 252 rodents including 138 (Apodemus speciosus), 45 (Apodemus argenteus), 42 (Myodes rufocanus) and 27 (Myodes rutilus) were collected from Hokkaido island, northern Japan, collected during 2010 to 2015. A 770 bp and 382 bp segment of the 16S rRNA and gltA genes, respectively, were amplified by nested PCR. Results were confirmed by cloning and sequencing of the positive PCR products. A reverse line blot hybridization (RLB) based on the 16S rRNA gene was then developed for the specific detection of AP-sd. The prevalence of AP-sd by nested PCR in sika deer was 51% (128/250). We detected this Anaplasma sp. for the first time in wild brown bears and rodents with a prevalence of 15% (2/13) and 2.4% (6/252), respectively. The sequencing results of the 16S rRNA and gltA gene amplicons were divergent from the selected A. phagocytophilum sequences in GenBank. Using a newly designed AP-sd specific probe for RLB has enabled us to specifically detect this Anaplasma species. Besides sika deer and cattle, wild brown bears and rodents were identified as potential reservoir hosts for AP-sd. This study provided a high throughput molecular method that specifically detects AP-sd, and which can be used to investigate its ecology and its potential as a threat to humans in Japan. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Highly specific fiber optic immunosensor coupled with immunomagnetic separation for detection of low levels of Listeria monocytogenes and L. ivanovii

    Science.gov (United States)

    2012-01-01

    Background Immunomagnetic separation (IMS) and immunoassays are widely used for pathogen detection. However, novel technology platforms with highly selective antibodies are essential to improve detection sensitivity, specificity and performance. In this study, monoclonal antibodies (MAbs) against Internalin A (InlA) and p30 were generated and used on paramagnetic beads of varying diameters for concentration, as well as on fiber-optic sensor for detection. Results Anti-InlA MAb-2D12 (IgG2a subclass) was specific for Listeria monocytogenes and L. ivanovii, and p30-specific MAb-3F8 (IgM) was specific for the genus Listeria. At all bacterial concentrations (103–108 CFU/mL) tested in the IMS assay; the 1-μm diameter MyOne beads had significantly higher capture efficiency (P Listeria antibody (9 %). Furthermore, capture efficiency for MyOne-2D12 was highly specific for L. monocytogenes and L. ivanovii. Subsequently, we captured L. monocytogenes by MyOne-2D12 and MyOne-3F8 from hotdogs inoculated with mono- or co-cultures of L. monocytogenes and L. innocua (10–40 CFU/g), enriched for 18 h and detected by fiber-optic sensor and confirmed by plating, light-scattering, and qPCR assays. The detection limit for L. monocytogenes and L. ivanovii by the fiber-optic immunosensor was 3 × 102 CFU/mL using MAb-2D12 as capture and reporter antibody. Selective media plating, light-scattering, and qPCR assays confirmed the IMS and fiber-optic results. Conclusions IMS coupled with a fiber-optic sensor using anti-InlA MAb is highly specific for L. monocytogenes and L. ivanovii and enabled detection of these pathogens at low levels from buffer or food. PMID:23176167

  13. Development of a new in vivo kit for detection of prostate specific antigen in human serum using immunoradiometric assay method

    International Nuclear Information System (INIS)

    Babaei, M. H.; Behradkia, P.; Shafii, M.; Movla, M.; Forutan, H.; Najafi, R.

    2006-01-01

    Prostate is a leading site for the cancer incidence, accounted for 31.0% of new cancer cases in men. Prostate-specific antigen is widely used in the detection and monitoring of the prostate cancer. Currently, immunoassay is used to detect Prostate-specific antigen in human serum. This technique is based on the interaction between antibody and antigen. The varied immunoassay formats and equipment to run the assays allow the users to measure the analytes rapidly, with the flexibility to run a small or a large number of samples. Among different immunoassay methods, immunoradiometric assay is a more sensitive and valuable detection approach. This study has been made in 4 parts: (1) purification of Prostate-specific antigen from seminal fluid; (2) preparation of hybridoma cells which secrete monoclonal antibody (mAb) against Prostate-specific antigen , (3) selection of pair monoclonal antibody among those antibodies, and finally (4) design of an immunoradiometric assay kit and it's quality control . The results of this study were: (1) obtaining a huge amount of Prostate-specific antigen as semi-purified and purified, that is a valuable material for preparation of standard kits; (2) preparation of 8 kinds of monoclonal antibodies; (3) finding 4 pairs of monoclonal antibodies which react with different epitopes on Prostate-specific antigen molecule; and (4) preparation of immunoradiometric assay kit for measuring Prostate-specific antigen concentration in human serum

  14. A highly sensitive and specific method for the screening detection of genetically modified organisms based on digital PCR without pretreatment.

    Science.gov (United States)

    Fu, Wei; Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Du, Zhixin; Tian, Wenying; Wang, Qin; Wang, Huiyu; Xu, Wentao; Zhu, Shuifang

    2015-08-04

    Digital PCR has developed rapidly since it was first reported in the 1990 s. It was recently reported that an improved method facilitated the detection of genetically modified organisms (GMOs). However, to use this improved method, the samples must be pretreated, which could introduce inaccuracy into the results. In our study, we explored a pretreatment-free digital PCR detection method for the screening for GMOs. We chose the CaMV35s promoter and the NOS terminator as the templates in our assay. To determine the specificity of our method, 9 events of GMOs were collected, including MON810, MON863, TC1507, MIR604, MIR162, GA21, T25, NK603 and Bt176. Moreover, the sensitivity, intra-laboratory and inter-laboratory reproducibility of our detection method were assessed. The results showed that the limit of detection of our method was 0.1%, which was lower than the labeling threshold level of the EU. The specificity and stability among the 9 events were consistent, respectively. The intra-laboratory and inter-laboratory reproducibility were both good. Finally, the perfect fitness for the detection of eight double-blind samples indicated the good practicability of our method. In conclusion, the method in our study would allow more sensitive, specific and stable screening detection of the GMO content of international trading products.

  15. Highly sensitive and specific protein detection via combined capillary isoelectric focusing and proximity ligation

    NARCIS (Netherlands)

    Padhan, N.; Yan, J.; Boge, A.; Scrivener, E.; Birgisson, H.; Zieba, A.; Gullberg, M.; Kamali-Moghaddam, M.; Claesson-Welsh, L.; Landegren, U.

    2017-01-01

    Detection and quantification of proteins and their post-translational modifications are crucial to decipher functions of complex protein networks in cell biology and medicine. Capillary isoelectric focusing together with antibody-based detection can resolve and identify proteins and their isoforms

  16. Multicolour probes for sequence-specific DNA detection based on graphene oxide.

    Science.gov (United States)

    Zhu, Qing; Xiang, Dongshan; Zhang, Cuiling; Ji, Xinghu; He, Zhike

    2013-09-21

    The bifunctionality of graphene oxide (GO) which can highly adsorb single-stranded DNA (ssDNA) and effectively quench the emission of organic dyes is reasonably utilized in a multiplexed DNA detection system, achieving sensitive and selective detection of HIV, VV and EV, respectively.

  17. Detection of magnetic-labeled antibody specific recognition events by combined atomic force and magnetic force microscopy

    International Nuclear Information System (INIS)

    Hong Xia; Liu Yanmei; Li Jun; Guo Wei; Bai Yubai

    2009-01-01

    Atomic force (AFM) and magnetic force microscopy (MFM) were developed to detect biomolecular specific interaction. Goat anti-mouse immunoglobulin (anti-IgG) was covalently attached onto gold substrate modified by a self-assembly monolayer of thioctic acid via 1-ethyl-3-[3-(dimethylamino) propyl] carbodiimide (EDC) activation. Magnetic-labeled IgG then specifically adsorbed onto anti-IgG surface. The morphological variation was identified by AFM. MFM was proved to be a fine assistant tool to distinguish the immunorecognized nanocomposites from the impurities by detection of the magnetic signal from magnetic-labeled IgG. It would enhance the understanding of biomolecular recognition process.

  18. Detection of magnetic-labeled antibody specific recognition events by combined atomic force and magnetic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Hong Xia [Center for Advanced Optoelectronic Functional Materials Research, Key Laboratory of UV Light-Emitting Materials and Technology, Ministry of Education, Northeast Normal University, Changchun 130024 (China); College of Chemistry, Jilin University, Changchun 130023 (China)], E-mail: xiahong@nenu.edu.cn; Liu Yanmei; Li Jun; Guo Wei; Bai Yubai [College of Chemistry, Jilin University, Changchun 130023 (China)

    2009-09-15

    Atomic force (AFM) and magnetic force microscopy (MFM) were developed to detect biomolecular specific interaction. Goat anti-mouse immunoglobulin (anti-IgG) was covalently attached onto gold substrate modified by a self-assembly monolayer of thioctic acid via 1-ethyl-3-[3-(dimethylamino) propyl] carbodiimide (EDC) activation. Magnetic-labeled IgG then specifically adsorbed onto anti-IgG surface. The morphological variation was identified by AFM. MFM was proved to be a fine assistant tool to distinguish the immunorecognized nanocomposites from the impurities by detection of the magnetic signal from magnetic-labeled IgG. It would enhance the understanding of biomolecular recognition process.

  19. Radio (111In) capillary tube leukocyte adherence inhibition assay for the detection of specific tumor-associated immunity

    International Nuclear Information System (INIS)

    Peng, R.; Myers, W.L.

    1984-01-01

    The specific tumor-associated immune response of C3H/HeJ mice was determined at various times after subcutaneous injection with a transplantable mammary adenocarcinoma (H2712) using a radio ( 111 In) leukocyte adherence inhibition (LAI) assay carried out in capillary tubes. Solubilized tumor-associated antigen prepared by a single phase 1-butanol extraction of the specific tumor and other transplantable tumors of different histological origin were used in the evaluation of LAI reactivity. The assay was found to be capable of detecting a significant antitumor response before the subcutaneous tumors became detectable by palpation. The response remained significant until the tumors were greater than 20 mm in diameter

  20. [Detection of fps tumor antigen with mono-specific anti-fps serum in tumors induced by acute transforming ALV].

    Science.gov (United States)

    Wang, Yixin; Chen, Hao; Zhao, Peng; Li, Jianliang; Cui, Zhizhong

    2013-03-04

    To prepare anti-fps mono-specific serum, and detect the fps antigen in tumors induced by acute transforming avian leukosis/sarcoma virus containing v-fps oncogene. Two part of v-fps gene was amplified by RT-PCR using the Fu-J viral RNA as the template. Mono-specific serum was prepared by immuning Kunming white mouse with both two recombinant infusion proteins expressed by the prokaryotic expression system. Indirect immunofluorescent assay was used to detect fps antigen in tumor tissue suspension cells and CEF infected by sarcoma supernatant. Immunohistochemical method was used to detect fps antigen in tumor tissue. The mouse mono-specific serum was specific as it had no cross reaction with classical ALV-J strains. The result reveals that the tumor tissue suspension cells, the CEF infected by sarcoma supernatant, and the slice immunohistochemistry of the sarcoma showed positive results. The anti-fps mono-specific serum was prepared, and the detection method was established, which laid the foundation for the study of viral biological characteristics and mechanism of tumourgenesis of acute transforming avian leukosis/sarcoma virus containing v-fps oncogene.

  1. Development of a sensitive and specific epitope-blocking ELISA for universal detection of antibodies to human enterovirus 71 strains.

    Directory of Open Access Journals (Sweden)

    Fang He

    Full Text Available BACKGROUND: Human Enterovirus 71 (EV71 is a common cause of hand, foot and mouth disease (HFMD in young children. It is often associated with severe neurological diseases and mortalities in recent outbreaks across the Asia Pacific region. Currently, there is no efficient universal antibody test available to detect EV71 infections. METHODOLOGY/PRINCIPAL FINDING: In the present study, an epitope-blocking ELISA was developed to detect specific antibodies to human EV71 viruses in human or animal sera. The assay relies on a novel monoclonal antibody (Mab 1C6 that specifically binds to capsid proteins in whole EV71 viruses without any cross reaction to any EV71 capsid protein expressed alone. The sensitivity and specificity of the epitope-blocking ELISA for EV71 was evaluated and compared to microneutralization using immunized animal sera to multiple virus genotypes of EV71 and coxsackieviruses. Further, 200 serum sample from human individuals who were potentially infected with EV71 viruses were tested in both the blocking ELISA and microneutralization. Results indicated that antibodies to EV71 were readily detected in immunized animals or human sera by the epitope blocking ELISA whereas specimens with antibodies to other enteroviruses yielded negative results. This assay is not only simpler to perform but also shows higher sensitivity and specificity as compared to microneutralization. CONCLUSION: The epitope-blocking ELISA based on a unique Mab 1C6 provided highly sensitive and 100% specific detection of antibodies to human EV71 viruses in human sera.

  2. Routine detection of Epstein-Barr virus specific T-cells in the peripheral blood by flow cytometry

    Science.gov (United States)

    Crucian, B. E.; Stowe, R. P.; Pierson, D. L.; Sams, C. F.

    2001-01-01

    The ability to detect cytomegalovirus-specific T-cells (CD4(+)) in the peripheral blood by flow cytometry has been recently described by Picker et al. In this method, cells are incubated with viral antigen and responding (cytokine producing) T-cells are then identified by flow cytometry. To date, this technique has not been reliably used to detect Epstein-Barr virus (EBV)-specific T-cells primarily due to the superantigen/mitogenic properties of the virus which non-specifically activate T-cells. By modifying culture conditions under which the antigens are presented, we have overcome this limitation and developed an assay to detect and quantitate EBV-specific T-cells. The detection of cytokine producing T-cells by flow cytometry requires an extremely strong signal (such as culture in the presence of PMA and ionomycin). Our data indicate that in modified culture conditions (early removal of viral antigen) the non-specific activation of T-cells by EBV is reduced, but antigen presentation will continue uninhibited. Using this method, EBV-specific T-cells may be legitimately detected using flow cytometry. No reduction in the numbers of antigen-specific T-cells was observed by the early removal of target antigen when verified using cytomegalovirus antigen (a virus with no non-specific T-cell activation properties). In EBV-seropositive individuals, the phenotype of the EBV-specific cytokine producing T-cells was evaluated using four-color flow cytometry and found to be CD45(+), CD3(+), CD4(+), CD45RA(-), CD69(+), CD25(-). This phenotype indicates the stimulation of circulating previously unactivated memory T-cells. No cytokine production was observed in CD4(+) T-cells from EBV-seronegative individuals, confirming the specificity of this assay. In addition, the use of four color cytometry (CD45, CD3, CD69, IFNgamma/IL-2) allows the total quantitative assessment of EBV-specific T-cells while monitoring the interference of EBV non-specific mitogenic activity. This method may

  3. Detecting Specific Health-Related Events Using an Integrated Sensor System for Vital Sign Monitoring

    Directory of Open Access Journals (Sweden)

    Mourad Adnane

    2009-09-01

    Full Text Available In this paper, a new method for the detection of apnea/hypopnea periods in physiological data is presented. The method is based on the intelligent combination of an integrated sensor system for long-time cardiorespiratory signal monitoring and dedicated signal-processing packages. Integrated sensors are a PVDF film and conductive fabric sheets. The signal processing package includes dedicated respiratory cycle (RC and QRS complex detection algorithms and a new method using the respiratory cycle variability (RCV for detecting apnea/hypopnea periods in physiological data. Results show that our method is suitable for online analysis of long time series data.

  4. A nucleic acid strand displacement system for the multiplexed detection of tuberculosis-specific mRNA using quantum dots

    Science.gov (United States)

    Gliddon, H. D.; Howes, P. D.; Kaforou, M.; Levin, M.; Stevens, M. M.

    2016-05-01

    The development of rapid, robust and high performance point-of-care diagnostics relies on the advancement and combination of various areas of research. We have developed an assay for the detection of multiple mRNA molecules that combines DNA nanotechnology with fluorescent nanomaterials. The core switching mechanism is toehold-mediated strand displacement. We have used fluorescent quantum dots (QDs) as signal transducers in this assay, as they bring many benefits including bright fluorescence and multiplexing abilities. The resulting assay is capable of multiplexed detection of long RNA targets against a high concentration of background non-target RNA, with high sensitivity and specificity and limits of detection in the nanomolar range using only a standard laboratory plate reader. We demonstrate the utility of our QD-based system for the detection of two genes selected from a microarray-derived tuberculosis-specific gene expression signature. Levels of up- and downregulated gene transcripts comprising this signature can be combined to give a disease risk score, making the signature more amenable for use as a diagnostic marker. Our QD-based approach to detect these transcripts could pave the way for novel diagnostic assays for tuberculosis.The development of rapid, robust and high performance point-of-care diagnostics relies on the advancement and combination of various areas of research. We have developed an assay for the detection of multiple mRNA molecules that combines DNA nanotechnology with fluorescent nanomaterials. The core switching mechanism is toehold-mediated strand displacement. We have used fluorescent quantum dots (QDs) as signal transducers in this assay, as they bring many benefits including bright fluorescence and multiplexing abilities. The resulting assay is capable of multiplexed detection of long RNA targets against a high concentration of background non-target RNA, with high sensitivity and specificity and limits of detection in the nanomolar

  5. Validation of an immunodiagnostic assay for detection of 13 Streptococcus pneumoniae serotype-specific polysaccharides in human urine.

    Science.gov (United States)

    Pride, Michael W; Huijts, Susanne M; Wu, Kangjian; Souza, Victor; Passador, Sherry; Tinder, Chunyan; Song, Esther; Elfassy, Arik; McNeil, Lisa; Menton, Ronald; French, Roger; Callahan, Janice; Webber, Chris; Gruber, William C; Bonten, Marc J M; Jansen, Kathrin U

    2012-08-01

    To improve the clinical diagnosis of pneumococcal infection in bacteremic and nonbacteremic community-acquired pneumonia (CAP), a Luminex technology-based multiplex urinary antigen detection (UAD) diagnostic assay was developed and validated. The UAD assay can simultaneously detect 13 different serotypes of Streptococcus pneumoniae by capturing serotype-specific S. pneumoniae polysaccharides (PnPSs) secreted in human urine. Assay specificity is achieved by capturing the polysaccharides with serotype-specific monoclonal antibodies (MAbs) on spectrally unique microspheres. Positivity for each serotype was based on positivity cutoff values calculated from a standard curve run on each assay plate together with positive- and negative-control urine samples. The assay is highly specific, since significant signals are detected only when each PnPS was paired with its homologous MAb-coated microspheres. Validation experiments demonstrated excellent accuracy and precision. The UAD assay and corresponding positivity cutoff values were clinically validated by assessing 776 urine specimens obtained from patients with X-ray-confirmed CAP. The UAD assay demonstrated 97% sensitivity and 100% specificity using samples obtained from patients with bacteremic, blood culture-positive CAP. Importantly, the UAD assay identified Streptococcus pneumoniae (13 serotypes) in a proportion of individuals with nonbacteremic CAP, a patient population for which the pneumococcal etiology of CAP was previously difficult to assess. Therefore, the UAD assay provides a specific, noninvasive, sensitive, and reproducible tool to support vaccine efficacy as well as epidemiological evaluation of pneumococcal disease, including CAP, in adults.

  6. Detection and Quantification of Male-Specific Fetal DNA in the Serum of Pregnant Cynomolgus Monkeys (Macaca fascicularis)

    Science.gov (United States)

    Yasmin, Lubna; Takano, Jun-ichiro; Nagai, Yasushi; Otsuki, Junko; Sankai, Tadashi

    2015-01-01

    Because of their developmental similarities to humans, nonhuman primates are often used as a model to study fetal development for potential clinical applications in humans. The detection of fetal DNA in maternal plasma or serum offers a source of fetal genetic material for prenatal diagnosis. However, no such data have been reported for cynomolgus monkeys (Macaca fascicularis), an important model in biomedical research. We have developed a specific, highly sensitive PCR system for detecting and quantifying male-specific fetal DNA in pregnant cynomolgus monkeys. We used multiplex quantitative real-time PCR to analyze cell-free DNA in maternal blood serum obtained from 46 pregnant monkeys at gestational weeks 5, 12, and 22. The presence of SRY gene and DYS14 Y chromosomal sequences was determined in 28 monkeys with male-bearing pregnancies. According to confirmation of fetal sex at birth, the probe and primers for detecting the Y chromosomal regions at each time point revealed 100% specificity of the PCR test and no false-positive or false-negative results. Increased levels of the SRY-specific sequences (mean, 4706 copies/mL serum DNA; range, 1731 to 12,625) and DYS14-specific sequences (mean, 54,814 copies/mL serum DNA; range, 4175–131,250 copies) were detected at week 22. The SRY- and DYS14-specific probes appear to be an effective combination of markers in a multiplex PCR system. To our knowledge, this report is the first to describe the detection of cell-free DNA in cynomolgus monkeys. PMID:25730760

  7. Love Wave Sensor for Prostate-Specific Membrane Antigen Detection Based on Hydrophilic Molecularly-Imprinted Polymer

    Directory of Open Access Journals (Sweden)

    Pingping Tang

    2018-05-01

    Full Text Available Prostate-specific membrane antigen (PSMA is a biomarker for prostate cancer (PCa, and a specific and reliable detection technique of PSMA is urgently required for PCa early diagnosis. A Love wave sensor has been widely studied for real-time sensing and highly sensitive applications, but the sensing unit needs special handling for selective detection purpose. In this study, we prepared a versatile Love wave sensor functionalized with molecularly-imprinted polymers (MIP, PSMA as the template molecule. To enhance the specific template bindings of MIP in pure aqueous solutions, facile reversible addition/fragmentation chain transfer (RAFT precipitation polymerization (RAFTPP was used to produce surface hydrophilic polymer brushes on MIP. The presence of hydrophilic polymer brushes on MIP improved its surface hydrophilicity and significantly reduced their hydrophobic interactions with template molecules in pure aqueous media. In detection process, the acoustic delay-line is confederative to a microfluidic chip and inserted in an oscillation loop. The real-time resonance frequency of the MIP-based Love wave sensor to different concentrations of PSMA was investigated. The limit of detection (LOD for this Love SAW sensor was 0.013 ng mL−1, which demonstrates that this sensor has outstanding performance in terms of the level of detection.

  8. Clustered Regularly Interspaced Short Palindromic Repeats/Cas9 Triggered Isothermal Amplification for Site-Specific Nucleic Acid Detection.

    Science.gov (United States)

    Huang, Mengqi; Zhou, Xiaoming; Wang, Huiying; Xing, Da

    2018-02-06

    A novel CRISPR/Cas9 triggered isothermal exponential amplification reaction (CAS-EXPAR) strategy based on CRISPR/Cas9 cleavage and nicking endonuclease (NEase) mediated nucleic acids amplification was developed for rapid and site-specific nucleic acid detection. CAS-EXPAR was primed by the target DNA fragment produced by cleavage of CRISPR/Cas9, and the amplification reaction performed cyclically to generate a large number of DNA replicates which were detected using a real-time fluorescence monitoring method. This strategy that combines the advantages of CRISPR/Cas9 and exponential amplification showed high specificity as well as rapid amplification kinetics. Unlike conventional nucleic acids amplification reactions, CAS-EXPAR does not require exogenous primers, which often cause target-independent amplification. Instead, primers are first generated by Cas9/sgRNA directed site-specific cleavage of target and accumulated during the reaction. It was demonstrated this strategy gave a detection limit of 0.82 amol and showed excellent specificity in discriminating single-base mismatch. Moreover, the applicability of this method to detect DNA methylation and L. monocytogenes total RNA was also verified. Therefore, CAS-EXPAR may provide a new paradigm for efficient nucleic acid amplification and hold the potential for molecular diagnostic applications.

  9. One-step isothermal detection of multiple KRAS mutations by forming SNP specific hairpins on a gold nanoshell.

    Science.gov (United States)

    Chung, Chan Ho; Kim, Joong Hyun

    2018-04-24

    We developed a one-step isothermal method for typing multiple KRAS mutations using a designed set of primers to form a hairpin on a gold nanoshell upon being ligated by a SNP specific DNA ligase after binding of targets. As a result, we could detect as low as 20 attomoles of KRAS mutations within 1 h.

  10. Evaluation of Amplification Targets for the Specific Detection of Bordetella pertussis Using Real-Time Polymerase Chain Reaction

    Directory of Open Access Journals (Sweden)

    Mohammad Rubayet Hasan

    2014-01-01

    Full Text Available BACKGROUND: Bordetella pertussis infections continue to be a major public health challenge in Canada. Polymerase chain reaction (PCR assays to detect B pertussis are typically based on the multicopy insertion sequence IS481, which offers high sensitivity but lacks species specificity.

  11. Wildlife detection dog training: A case study on achieving generalization between target odor variations while retaining specificity

    NARCIS (Netherlands)

    Oldenburg, Cor; Schoon, Adee; Heitkönig, I.M.A.

    2016-01-01

    Wildlife detection dogs are required to correctly discriminate target wildlife species odor from nontarget
    species odors (specificity), while enabling some degree of target odor variation (generality). Because
    there is no standardized training protocol, and little knowledge on training

  12. A rapid and specific detection of pathogenic serovar Salmonella typhimurium by loop-mediated isothermal amplification method (LAMP

    Directory of Open Access Journals (Sweden)

    Hadi Ravan

    2017-09-01

    Discussion and conclusion: As a result of a high sensitivity and specificity of the method as well as its low cost per assay, it could be concluded that the present LAMP assay is a powerful, accurate, and efficient method for detecting pathogenic serovar Salmonella typhimurium in food-processing industries and diagnostic laboratories.

  13. Person-Specific Face Detection in a Scene with Optimum Composite Filtering and Colour-Shape Information

    Directory of Open Access Journals (Sweden)

    Seokwon Yeom

    2013-01-01

    Full Text Available Face detection and recognition have wide applications in robot vision and intelligent surveillance. However, face identification at a distance is very challenging because long-distance images are often degraded by low resolution, blurring and noise. This paper introduces a person-specific face detection method that uses a nonlinear optimum composite filter and subsequent verification stages. The filter's optimum criterion minimizes the sum of the output energy generated by the input noise and the input image. The composite filter is trained with several training images under long-distance modelling. The candidate facial regions are provided by the filter's outputs of the input scene. False alarms are eliminated by subsequent testing stages, which comprise skin colour and edge mask filtering tests. In the experiments, images captured by a webcam and a CCTV camera are processed to show the effectiveness of the person-specific face detection system at a long distance.

  14. Increased sequence diversity coverage improves detection of HIV-Specific T cell responses

    DEFF Research Database (Denmark)

    Frahm, N.; Kaufmann, D.E.; Yusim, K.

    2007-01-01

    The accurate identification of HIV-specific T cell responses is important for determining the relationship between immune response, viral control, and disease progression. HIV-specific immune responses are usually measured using peptide sets based on consensus sequences, which frequently miss res...

  15. Detection of Two Types of Weed through Machine Vision System: Improving Site-Specific Spraying

    Directory of Open Access Journals (Sweden)

    S Sabzi

    2018-03-01

    Full Text Available Introduction With increase in world population, one of the approaches to provide food is using site-specific management system or so-called precision farming. In this management system, management of crop production inputs such as fertilizers, lime, herbicides, seed, etc. is done based on farm location features, with the aim of reducing waste, increasing revenues and maintaining environmental quality. Precision farming involves various aspects and is applicable on farm fields at all stages of tillage, planting, and harvesting. Today, in line with precision farming purposes, and to control weeds, pests, and diseases, all the efforts of specialists in precision farming is to reduce the amount of chemical substances in products. Although herbicides improve the quality and quantity of agricultural production, the possibility of applying inappropriately and unreasonably is very high. If the dose is too low, weed control is not performed correctly. Otherwise, If the dosage is too high, herbicides can be toxic for crops, can be transferred to soil and stay in it for a long time, and can penetrate to groundwater. By applying herbicides to variable rate, the potential for significant cost savings and reduced environmental damage to the products and environment will be possible. It is evident that in large-scale modern agriculture, individual management of each plant without using some advanced technologies is not possible. using machine vision systems is one of precision farming techniques to identify weeds. This study aimed to detect three plant such as Centaurea depressa M.B, Malvaneglecta and Potato plant using machine vision system. Materials and Methods In order to train algorithm of designed machine vision system, a platform that moved with the speed of 10.34 was used for shooting of Marfona potato fields. This platform was consisted of a chassis, camera (DFK23GM021,CMOS, 120 f/s, Made in Germany, and a processor system equipped with Matlab 2015

  16. ZnO nanorod biosensor for highly sensitive detection of specific protein binding

    International Nuclear Information System (INIS)

    Kim, Jin Suk; Park, Won Il; Lee, Chul Ho; Yi, Gyu Chul

    2006-01-01

    We report on the fabrication of electrical biosensors based on functionalized ZnO nanorod surfaces with biotin for highly sensitive detection of biological molecules. Due to the clean interface and easy surface modification, the ZnO nanorod sensors can easily detect streptavidin binding down to a concentration of 25 nM, which is more sensitive than previously reported one-dimensional (1D) nanostructure electrical biosensors. In addition, the unique device structure with a micrometer-scale hole at the center of the ZnO nanorod's conducting channel reduces the leakage current from the aqueous solution, hence enhancing device sensitivity. Moreover, ZnO nanorod field-effect-transistor (FET) sensors may open up opportunities to create many other oxide nanorod electrical sensors for highly sensitive and selective real-time detection of a wide variety of biomolecules.

  17. Detection of Legionella bozemanae, a New Cause of Septic Arthritis, by PCR Followed by Specific Culture

    DEFF Research Database (Denmark)

    Just, Søren Andreas; Knudsen, John Bonde; Uldum, Søren Anker

    2012-01-01

    Legionella bozemanae is a rare isolate in clinical specimens. We describe a case of joint infection due to L. bozemanae in an immunocompromised patient with dermatomyositis. Without the use of PCR screening or culture on specialized medium, the organism would not have been detected.......Legionella bozemanae is a rare isolate in clinical specimens. We describe a case of joint infection due to L. bozemanae in an immunocompromised patient with dermatomyositis. Without the use of PCR screening or culture on specialized medium, the organism would not have been detected....

  18. Generation of monoclonal antibodies against prostate specific antigen (PSA) for the detection of PSA and its purification

    International Nuclear Information System (INIS)

    Acevedo Castro, Boris Ernesto

    2012-01-01

    The prostate cancer in Cuba is a problem of health (2672 diagnosed cases and 2769 deaths in 2007). Various diagnostic methods have been implemented for the detection and management of this disease, emphasizing among them (PSA) prostate-specific antigen serological determination. At this work was generated and characterized a panel of 11 antibodies (AcMs) monoclonal IgG1 detected with high affinity described major epitopes of the PSA, both in solution and attached to the test plate. From the panel obtained AcMs was the standardization of an essay type ELISA for the detection of serum total PSA (associated and free) equimolar, based on antibody monoclonal CB-PSA.4 in the coating and the CB-PSA.9 coupled with biotin as liner, with a detection limit of 0.15 ng/mL. Similarly, standardized system for detection in serum free PSA, based on the AcMs CB-PSA.4 (coating) and CB-PSA.2 coupled with biotin (liner), with a detection limit of 0.5 ng/mL. Finally, with the purpose of using PSA as standard in trials type ELISA, developed a simple method of inmunopurificación based on the AcM, CB-PSA.2, which was obtained the PSA with a purity exceeding 90%. Immunoassay Centre on the basis of the AcMs panel and the results of this study, developed and recorded two diagnostic systems for the detection of PSA in human serum. (author)

  19. NDRG4, an early detection marker for colorectal cancer, is specifically expressed in enteric neurons

    NARCIS (Netherlands)

    Vaes, N.; Lentjes, M. H. F. M.; Gijbels, M. J.; Rademakers, G.; Daenen, K. L.; Boesmans, W.; Wouters, K. A. D.; Geuzens, A.; Qu, X.; Steinbusch, H. P. J.; Rutten, B. P. F.; Baldwin, S. H.; Sharkey, K. A.; Hofstra, R. M. W.; van Engeland, M.; Vanden Berghe, P.; Melotte, V.

    2017-01-01

    Background: Promoter methylation of N-myc Downstream-Regulated Gene 4 (NDRG4) in fecal DNA is an established early detection marker for colorectal cancer (CRC). Despite its connection to CRC, NDRG4 is predominantly studied in brain and heart, with little to no knowledge about its expression or role

  20. Modification of ISFETs with a monolayer of latex beads for specific detection of proteins

    NARCIS (Netherlands)

    Besselink, G.A.J.; Schasfoort, Richardus B.M.; Bergveld, Piet

    2003-01-01

    The so-called ion-step method is a novel potentiometric approach that can detect protein adsorbed onto the gate area of modified ion-sensitive field-effect transistors (ISFETs). In this report, a generic technology is described for immobilization of peptides and proteins to the ISFET gate in order

  1. Visual working memory and threat monitoring: Spider fearfuls show disorder-specific change detection

    NARCIS (Netherlands)

    Reinecke, A.; Becker, E.S.; Rinck, M.

    2010-01-01

    Previous studies of biased information processing in anxiety addressed biases of attention and memory, but little is known about the processes taking place between them: visual working memory (VWM) and monitoring of threat. We investigated these processes with a change detection paradigm. In

  2. A new highly specific and robust yeast androgen bioassay for the detection of agonist and antagonists

    NARCIS (Netherlands)

    Bovee, T.F.H.; Helsdingen, J.R.; Hamers, A.R.M.; Duursen, van M.; Nielen, M.W.F.; Hoogenboom, L.A.P.

    2007-01-01

    Public concern about the presence of natural and anthropogenic compounds which affect human health by modulating normal endocrine functions is continuously growing. Fast and simple high-throughput screening methods for the detection of hormone activities are thus indispensable. During the last two

  3. [Use of new immunoglobulin isotype-specific ELISA-systems to detect Salmonella infections in pigs].

    Science.gov (United States)

    Ehlers, Joachim; Alt, Michael; Trepnau, Daniela; Lehmann, Jörg

    2006-01-01

    In Germany, the program for controlling salmonella infections in pigs is based on tests detecting salmonella-lipopolysaccharide (LPS) induced antibodies in meat-juice or blood. These conventional tests which are based on the technology of enzyme-linked immunosorbent assay (ELISA) detect exclusively or mainly immunoglobulin(lg)G antibodies. Meanwhile, novel ELISA systems (WCE-ELISA, 3-Isotype-Screening-ELISA) have been developed, which additionally detect the antibody classes IgM and IgA.This fact enables the registration of fresh salmonella infections (starting with day 5 p.i.) and thus, the distinction between early and older infections. The results show that animals with early salmonella infections appear significantly more often in herds with a high than with a low prevalence. With the newly developed tests this group of animals can be detected much more efficiently and precisely than with the tests used so far. Due to their clearly improved sensitivity the application of the WCE-ELISA and the 3-Isotype-Screening-ELISA in terms of the QS-Salmonella-Monitoring program can therefore significantly improve the selection of farms with potential salmonella excretors. Additionally, the WCE-ELISA can be applied very suitable for the examination of individual animals.

  4. Lightweight Detection of Android-specific Code Smells : The aDoctor Project

    NARCIS (Netherlands)

    Palomba, F.; Di Nucci, D.; Panichella, A.; Zaidman, A.E.; De Lucia, Andrea; Pinzger, Martin; Bavota, Gabriele; Marcus, Andrian

    2017-01-01

    Code smells are symptoms of poor design solutions applied by programmers during the development of software systems. While the research community devoted a lot of effort to studying and devising approaches for detecting the traditional code smells defined by Fowler, little knowledge and support

  5. Detection of DNA specific sequences of Spongospora subterranea in soil and potato tubers

    Directory of Open Access Journals (Sweden)

    Cristian Oswaldo Saavedra Rodríguez

    2004-01-01

    Full Text Available A test has been developed for early identification of the casual agent for potato powdery scab (Spongospora subterranea fs subterranea. Identification was carried out in seeds and soil where this tuber is grown. A polymerase chain reaction (PCR was set up for detecting 372, 390 and 391 bp ribosomal DNA internal transcribed spacer sequences (ITS in the S. subterraneagenome. A method for extracting and purifying DNA from infected plant material (potato root nodes and pustules on the potato was standardised. Plant tissue was obtained by potato tuber propagation using an inoculum from the pathogen in greenhouse conditions. After the PCR had been optimised and its sensitivity determined, a molecular methodology was validated by examining plant material infected with S. subterranea and soil samples infested with the pathogen obtained from the departments of Cundinamarca and Nariño. The PCR detected S. subterranea DNA from infected material and soil samples (all thirty samples from the experimental area analysed proved PCR positive. These results show that this molecular method was not just useful for the early detection of the pathogen in soil samples but as a tool for detecting or determining the possible presence of this micro-organism in places that have been declared f ree of S. subterranea and an effective form of quality control in producing the certif ied potato seed. Key words: Powdery scab, cystosori, internal transcribed spacer, PCR, plasmodiophorid.

  6. Comparison of specificity and sensitivity of immunochemical and molecular techniques for reliable detection of Erwinia amylovora

    Czech Academy of Sciences Publication Activity Database

    Kokošková, B.; Mráz, Ivan; Hýblová, Jana

    2007-01-01

    Roč. 52, č. 2 (2007), s. 175-182 ISSN 0015-5632 R&D Projects: GA AV ČR(CZ) 1QS500510558 Institutional research plan: CEZ:AV0Z50510513 Keywords : Erwinia amylovora * detection Subject RIV: EE - Microbiology, Virology Impact factor: 0.989, year: 2007

  7. PCR Primer Specific CaMV 35S Promoter to Detect Transgenic Soybean in Indonesia Commercial Soy Bean and Tempeh

    Directory of Open Access Journals (Sweden)

    Tri Joko Raharjo

    2017-11-01

    Full Text Available In the framework of the supervision and enforcement of the regulation regarding the content of soybean transgenic in food and processed foods such as tempeh, a reliable testing method is indispensable. Performance specific primer PCR amplification with promoter of CaMV 35S tested to detect the presence of GMOs. The parameters tested were specificity, precision and cut off detection using CRM transgenic soybean. The method is reliable to detect transgenic soybean specifically and has the annealing temperature at 59 °C during the 30 cycle standard PCR condition. The method did not show any false positive and false negative results meaning good precision. The cut off the methods is up to 2 copies total DNA of soybean or less than 104 copies of the CaMV 35S promoter. Observation to the commercial soybeans and tempeh found that most of the commercially available soybean in Indonesia are transgenic (8 of 10 sample while all tested tempeh sample were detected have been fermented from transgenic soybeans.

  8. A new aptamer/graphene interdigitated gold electrode piezoelectric sensor for rapid and specific detection of Staphylococcus aureus.

    Science.gov (United States)

    Lian, Yan; He, Fengjiao; Wang, Huan; Tong, Feifei

    2015-03-15

    A novel aptamer/graphene interdigitated gold electrode piezoelectric sensor was developed for the rapid and specific detection of Staphylococcus aureus (S. aureus) by employing S. aureus aptamer as a biological recognition element. 4-Mercaptobenzene-diazonium tetrafluoroborate (MBDT) salt was used as a molecular cross-linking agent to chemically bind graphene to interdigital gold electrodes (IDE) that are connected to a series electrode piezoelectric quartz crystal (SPQC). S. aureus aptamers were assembly immobilized onto graphene via the π-π stacking of DNA bases. Due to the specific binding between S. aureus and aptamer, when S. aureus is present, the DNA bases interacted with the aptamer, thereby dropping the aptamer from the surface of the graphene. The electric parameters of the electrode surface was changed and resulted in the change of oscillator frequency of the SPQC. This detection was completed within 60min. The constructed sensor demonstrated a linear relationship between resonance frequency shifts with bacterial concentrations ranging from 4.1×10(1)-4.1×10(5)cfu/mL with a detection limit of 41cfu/mL. The developed strategy can detect S. aureus rapidly and specifically for clinical diagnosis and food testing. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Immunodiagnosis of paracoccidioidomycosis due to Paracoccidioides brasiliensis using a latex test: detection of specific antibody anti-gp43 and specific antigen gp43.

    Directory of Open Access Journals (Sweden)

    Priscila Oliveira Dos Santos

    2015-02-01

    Full Text Available Paracoccidioidomycosis (PCM is a life-threatening systemic disease and is a neglected public health problem in many endemic regions of Latin America. Though several diagnostic methods are available, almost all of them present with some limitations.A latex immunoassay using sensitized latex particles (SLPs with gp43 antigen, the immunodominant antigen of Paracoccidioides brasiliensis, or the monoclonal antibody mAb17c (anti-gp43 was evaluated for antibody or antigen detection in sera, cerebrospinal fluid (CSF, and bronchoalveolar lavage (BAL from patients with PCM due to P. brasiliensis. The gp43-SLPs performed optimally to detect specific antibodies with high levels of sensitivity (98.46%, 95% CI 91.7-100.0, specificity (93.94%, 95% CI 87.3-97.7, and positive (91.4% and negative (98.9% predictive values. In addition, we propose the use of mAb17c-SLPs to detect circulating gp43, which would be particularly important in patients with immune deficiencies who fail to produce normal levels of immunoglobulins, achieving good levels of sensitivity (96.92%, 95% CI 89.3-99.6, specificity (88.89%, 95% CI 81.0-94.3, and positive (85.1% and negative (97.8% predictive values. Very good agreement between latex tests and double immune diffusion was observed for gp43-SLPs (k = 0.924 and mAb17c-SLPs (k = 0.850, which reinforces the usefulness of our tests for the rapid diagnosis of PCM in less than 10 minutes. Minor cross-reactivity occurred with sera from patients with other fungal infections. We successfully detected antigens and antibodies from CSF and BAL samples. In addition, the latex test was useful for monitoring PCM patients receiving therapy.The high diagnostic accuracy, low cost, reduced assay time, and simplicity of this new latex test offer the potential to be commercialized and makes it an attractive diagnostic assay for use not only in clinics and medical mycology laboratories, but mainly in remote locations with limited laboratory infrastructure

  10. Determination of the species specificity of the primers for the detection of chicken and turkey meat by realtime PCR method

    Directory of Open Access Journals (Sweden)

    Lenka Maršálková

    2014-07-01

    Full Text Available The aim of this work was to use TaqMan Real-Time PCR for quantitative authentication of chicken and turkey meat. To meet this purpose, a specific pair of primers and TaqMan probe was used. The test was aimed at identifying the reaction cycle of turkey and chicken meat using by two sets of primers. With first set of primer designed for chicken we obtained the following results: Cp = 16.18 for 100% chicken DNA Cp = 29, 18 100% turkey DNA It was also amplified DNA of pig that exceeded the detection threshold fluorescence intensities in the 31.07 cycle (Cp = 31.07. Using primers designed for turkey we obtained the following results Cp = 31.16 for 100% CHDNA, Cp =16.18 100% TDNA. It was also amplified the 100% DNA of rabbit in 31.63 cycle (Cp = 31.63 and deer in cycle 32 (Cp = 32. The DNA of all other animal species was amplificated after more than 35 cycles (Cp >35. It follows that the second detection primer pair is specific enough to unrelated species of animals by 30 cycles of the reaction. Species authentication based on DNA analysis from this perspective overcomes all the shortcomings of proteins. At present, DNA analysis use different types of PCR. Is the most progressive Real-time PCR, which is suitable for the specific use of detection (primers and TaqMan probe. The TaqMan Real-time PCR is within the sensitivity and specificity, clearly one of the best methods for identifying the species of chicken and turkey meat. The specificity of this method, however, depends primarily on the specificity of the primers and TaqMan probe. The 30 cycle reaction was chosen by us as the threshold for specificity using primers for authentication chicken and turkey meat.

  11. The sensitivity and specificity of the Middlesex Elderly Assessment of Mental State (MEAMS) for detecting cognitive impairment after stroke.

    Science.gov (United States)

    Cartoni, A; Lincoln, N B

    2005-03-01

    The aim of the study was to assess the sensitivity and specificity of the MEAMS (Golding, 1989) for detecting cognitive impairment after stroke. Stroke patients admitted to hospital received a cognitive screening assessment, the MEAMS, and a detailed cognitive assessment. The information obtained from the detailed assessment was summarised in a structured written report. From the conclusions in these reports, patients were classified as "impaired" or "not impaired" in perception, memory, executive function and language. The sensitivity and specificity of the MEAMS subtests and the overall number of tests passed were determined in relation to the presence of impairment, as given in the overall conclusion of the written reports. There were 30 stroke patients, aged 58 to 92 (mean 75.80, SD 7.94) years. Of these, 17 were men and 13 were women. The sensitivity of the MEAMS subtests ranged from 11% to 100% and the specificity ranged from 69% to 100%. The sensitivity of the overall MEAMS score was 52% and the specificity was 100%, using a cut-off score of 3 or more fails to indicate impairment. Three subtests, Orientation, Naming and Unusual views had 81% sensitivity and 50% specificity for detecting problems in language, perception or memory. The MEAMS was not a sensitive screen for overall cognitive impairment or for memory, perceptual, language, or executive function problems after stroke, but it was specific. Although screening for cognitive impairment is important, the MEAMS is not recommended as the sole method, as it produces an unacceptably high false negative rate. Three subtests (Orientation, Naming and Unusual views) had 81% sensitivity and 50% specificity for detecting cognitive problems in language, perception or memory after stroke.

  12. Detection and Characterization of Reactive Oxygen and Nitrogen Species in Biological Systems by Monitoring Species-Specific Products.

    Science.gov (United States)

    Hardy, Micael; Zielonka, Jacek; Karoui, Hakim; Sikora, Adam; Michalski, Radosław; Podsiadły, Radosław; Lopez, Marcos; Vasquez-Vivar, Jeannette; Kalyanaraman, Balaraman; Ouari, Olivier

    2018-05-20

    Since the discovery of the superoxide dismutase enzyme, the generation and fate of short-lived oxidizing, nitrosating, nitrating, and halogenating species in biological systems has been of great interest. Despite the significance of reactive oxygen species (ROS) and reactive nitrogen species (RNS) in numerous diseases and intracellular signaling, the rigorous detection of ROS and RNS has remained a challenge. Recent Advances: Chemical characterization of the reactions of selected ROS and RNS with electron paramagnetic resonance (EPR) spin traps and fluorescent probes led to the establishment of species-specific products, which can be used for specific detection of several forms of ROS and RNS in cell-free systems and in cultured cells in vitro and in animals in vivo. Profiling oxidation products from the ROS and RNS probes provides a rigorous method for detection of those species in biological systems. Formation and detection of species-specific products from the probes enables accurate characterization of the oxidative environment in cells. Measurement of the total signal (fluorescence, chemiluminescence, etc.) intensity does not allow for identification of the ROS/RNS formed. It is critical to identify the products formed by using chromatographic or other rigorous techniques. Product analyses should be accompanied by monitoring of the intracellular probe level, another factor controlling the yield of the product(s) formed. More work is required to characterize the chemical reactivity of the ROS/RNS probes, and to develop new probes/detection approaches enabling real-time, selective monitoring of the specific products formed from the probes. Antioxid. Redox Signal. 28, 1416-1432.

  13. An Impedance Aptasensor with Microfluidic Chips for Specific Detection of H5N1 Avian Influenza Virus

    Directory of Open Access Journals (Sweden)

    Jacob Lum

    2015-07-01

    Full Text Available In this research a DNA aptamer, which was selected through SELEX (systematic evolution of ligands by exponential enrichment to be specific against the H5N1 subtype of the avian influenza virus (AIV, was used as an alternative reagent to monoclonal antibodies in an impedance biosensor utilizing a microfluidics flow cell and an interdigitated microelectrode for the specific detection of H5N1 AIV. The gold surface of the interdigitated microelectrode embedded in a microfluidics flow cell was modified using streptavidin. The biotinylated aptamer against H5N1 was then immobilized on the electrode surface using biotin–streptavidin binding. The target virus was captured on the microelectrode surface, causing an increase in impedance magnitude. The aptasensor had a detection time of 30 min with a detection limit of 0.0128 hemagglutinin units (HAU. Scanning electron microscopy confirmed the binding of the target virus onto the electrode surface. The DNA aptamer was specific to H5N1 and had no cross-reaction to other subtypes of AIV (e.g., H1N1, H2N2, H7N2. The newly developed aptasensor offers a portable, rapid, low-cost alternative to current methods with the same sensitivity and specificity.

  14. Electrochemical detection of specific DNA and respiratory activity of Escherichia coli

    International Nuclear Information System (INIS)

    Yamanaka, Keiichiro; Ikeuchi, Tomohiko; Saito, Masato; Nagatani, Naoki; Tamiya, Eiichi

    2012-01-01

    We present two rapid and simplified detection methods for Escherichia coli involving the use of a hand-held potentiostat and a disposable screen-printed carbon electrode. E. coli is one of the indicator organisms used to access for food safety. Commonly, microbiological culture techniques take more than one day to yield results and therefore, a simple, cost-effective, in situ detection system is required for testing food safety. This report describes two complementary techniques for high- and low-sensitivity detection of E. coli. High-sensitivity detection relies upon quantification of DNA amplification by using polymerase chain reaction (PCR), while the simplified, low-sensitivity detection can be obtained through measurement of oxygen consumption due to respiration; importantly, both techniques utilize the same type of electrode. The former entails mixing the PCR mixture with Hoechst, an electro-active DNA intercalator, and then, measuring the oxidation current. Binding of Hoechst molecules to the amplified DNA causes the peak current to decrease because of the slow diffusion of the Hoechst-amplified DNA complex to the electrode surface. The results showed that the oxidation peak current of Hoechst decreased depending on the number of E. coli cells added to the PCR mixture as the template for amplification, and the sensitivity of the method was as low as a single bacterium. Oxygen consumption was detected by direct measurement of the cell-containing culture medium. This method required only 10 μL to be applied on the screen-printed electrode, and the reduction in oxygen current was clearly observed within 30 min when a minimum of 1 × 10 5 cells were present. These results were obtained without purifying the culture, and the samples were applied onto the electrode without any surface modifications. The techniques describes in this report are versatile, because they require the same type of electrode, have simplistic nature, use a hand-held potentiostat, and have

  15. Loop-mediated isothermal amplification (LAMP) test for specific and rapid detection of Brucella abortus in cattle.

    Science.gov (United States)

    Karthik, K; Rathore, Rajesh; Thomas, Prasad; Arun, T R; Viswas, K N; Agarwal, R K; Manjunathachar, H V; Dhama, Kuldeep

    2014-01-01

    Brucella abortus, the major causative agent of abortion in cattle and a zoonotic pathogen, needs to be diagnosed at an early stage. Loop-mediated isothermal amplification (LAMP) test is easy to perform and also promising to be adapted at field level. To develop a LAMP assay for specific and rapid detection of B. abortus from clinical samples of cattle. LAMP primers were designed targeting BruAb2_0168 region using specific software tool and LAMP was optimized. The developed LAMP was tested for its specificity with 3 Brucella spp. and 11 other non-Brucella spp. Sensitivity of the developed LAMP was also carried out with known quantity of DNA. Cattle whole blood samples and aborted fetal stomach contents were collected and used for testing with developed LAMP assay and results were compared with polymerase chain reaction (PCR). The developed LAMP assay works at 61 °C for 60 min and the detection limit was observed to be 100-fold more than the conventional PCR that is commonly used for diagnosis of B. abortus. Clinical sensitivity and specificity of the developed LAMP assay was 100% when compared with Rose Bengal plate test and standard tube agglutination test. SYB® green dye I was used to visualize the result with naked eye. The novelty of the developed LAMP assay for specifically detecting B. abortus infection in cattle along with its inherent rapidness and high sensitivity can be employed for detecting this economically important pathogen of cattle at field level as well be exploited for screening of human infections.

  16. An RNAi-Enhanced Logic Circuit for Cancer Specific Detection and Destruction

    Science.gov (United States)

    2013-02-01

    monomeric protein secreted by Corynebacterium diphtheriae, and pro-apoptotic members of Bcl-2 family: mBax (Mus musculus), hBax ( Homo sapiens ), and its...Gata3 mStaple. Intron- feature sequences – donor site, branch point, poly- pyrimidine tract, and acceptor site – were selected based on previously...sequences found in literature our intron features were chosen according SplicePort [4], an online analyzer that detects the likelihood of splicing to

  17. Network Traffic Features for Anomaly Detection in Specific Industrial Control System Network

    Directory of Open Access Journals (Sweden)

    Matti Mantere

    2013-09-01

    Full Text Available The deterministic and restricted nature of industrial control system networks sets them apart from more open networks, such as local area networks in office environments. This improves the usability of network security, monitoring approaches that would be less feasible in more open environments. One of such approaches is machine learning based anomaly detection. Without proper customization for the special requirements of the industrial control system network environment, many existing anomaly or misuse detection systems will perform sub-optimally. A machine learning based approach could reduce the amount of manual customization required for different industrial control system networks. In this paper we analyze a possible set of features to be used in a machine learning based anomaly detection system in the real world industrial control system network environment under investigation. The network under investigation is represented by architectural drawing and results derived from network trace analysis. The network trace is captured from a live running industrial process control network and includes both control data and the data flowing between the control network and the office network. We limit the investigation to the IP traffic in the traces.

  18. Oligonucleotide-stabilized fluorescent silver nanoclusters for the specific and sensitive detection of biotin.

    Science.gov (United States)

    Xiong, Xiaoli; Tang, Yan; Zhao, Jingjin; Zhao, Shulin

    2016-02-21

    A novel biotin fluorescent probe based on oligonucleotide-stabilized silver nanoclusters (DNA-AgNCs) was synthesized by employing a biotinylated cytosine-rich sequence as a synthesized template. The fluorescence properties of the DNA-AgNCs are related to the modified position of the DNA. When biotin is linked to the middle thymine base of the DNA sequence, the DNA-AgNCs emit the strongest fluorescence. Moreover, the stability of the DNA-AgNCs was affected by avidin through biotin-avidin binding, quenching the fluorescence of the DNA-AgNCs. In contrast, if free biotin is further introduced into this system, the quenching is apparently weakened by competition, leading to the restoration of fluorescence. This phenomenon can be utilized for the detection of biotin. Under the optimal conditions, the fluorescence recovery is linearly proportional to the concentration of biotin in the range of 10 nM-1.0 μM with a detection limit of 6.0 nM. This DNA-AgNCs probe with excellent fluorescent properties is sensitive and selective for the detection of biotin and has been applied for the determination of biotin in wheat flour.

  19. Rapid detection and purification of sequence specific DNA binding proteins using magnetic separation

    Directory of Open Access Journals (Sweden)

    TIJANA SAVIC

    2006-02-01

    Full Text Available In this paper, a method for the rapid identification and purification of sequence specific DNA binding proteins based on magnetic separation is presented. This method was applied to confirm the binding of the human recombinant USF1 protein to its putative binding site (E-box within the human SOX3 protomer. It has been shown that biotinylated DNA attached to streptavidin magnetic particles specifically binds the USF1 protein in the presence of competitor DNA. It has also been demonstrated that the protein could be successfully eluted from the beads, in high yield and with restored DNA binding activity. The advantage of these procedures is that they could be applied for the identification and purification of any high-affinity sequence-specific DNA binding protein with only minor modifications.

  20. Species-specific detection and quantification of common barnacle larvae from the Japanese coast using quantitative real-time PCR.

    Science.gov (United States)

    Endo, Noriyuki; Sato, Kana; Matsumura, Kiyotaka; Yoshimura, Erina; Odaka, Yukiko; Nogata, Yasuyuki

    2010-11-01

    Species-specific detection and quantification methods for barnacle larvae using quantitative real-time polymerase chain reaction (qPCR) were developed. Species-specific primers for qPCR were designed for 13 barnacle species in the mitochondrial 12S ribosomal RNA gene region. Primer specificity was examined by PCR using template DNA extracted from each of the 13 barnacle species, other unidentified barnacle species, and field collected zooplankton samples. The resulting PCR products comprised single bands following agarose gel electrophoresis when the templates corresponded to primers. The amplifications were highly species-specific even for the field plankton samples. The field plankton samples were subjected to qPCR assay. The calculated DNA contents for each barnacle species were closely correlated with the number of larvae measured by microscopic examination. The method could be applied to quantify barnacle larvae in natural plankton samples.

  1. The Value of Urine Specific Gravity in Detecting Diabetes Insipidus in a Patient with Uncontrolled Diabetes Mellitus

    Science.gov (United States)

    Akarsu, Ersin; Buyukhatipoglu, Hakan; Aktaran, Sebnem; Geyik, Ramazan

    2006-01-01

    When a patient with diabetes mellitus presents with worsening polyuria and polydipsia, what is a sensible, cost-effective approach? We report the unique coincidence of type 2 diabetes mellitus and diabetes insipidus. A 46-year-old woman with poorly controlled type 2 diabetes complained of polyuria with a daily output of 5 L. Although urinalysis demonstrated significant glucosuria, diabetes insipidus was suspected owing to a low urine specific gravity (1.008). The low specific gravity persisted during a water deprivation test. Ultimately, diabetes insipidus was confirmed when urine specific gravity and urine osmolality normalized following desmopressin administration. This case emphasizes the importance of accurately interpreting the urine specific gravity in patients with polyuria and diabetes mellitus to detect diabetes insipidus. PMID:17026722

  2. Detection of Avian Antigen-Specific T Cells Induced by Viral Vaccines

    DEFF Research Database (Denmark)

    Dalgaard, Tina Sørensen; Norup, Liselotte Rothmann; Juul-Madsen, Helle Risdahl

    2016-01-01

    Live attenuated viral vaccines are widely used in commercial poultry production, but the development of new effective inactivated/subunit vaccines is needed. Studies of avian antigen-specific T cells are primarily based on analyses ex vivo after activating the cells with recall antigen. There is ......Live attenuated viral vaccines are widely used in commercial poultry production, but the development of new effective inactivated/subunit vaccines is needed. Studies of avian antigen-specific T cells are primarily based on analyses ex vivo after activating the cells with recall antigen...

  3. 99MTC Alpha-Fetoprotein: A Novel, Specific Agent for the Detection of Human Breast Cancer

    National Research Council Canada - National Science Library

    Line, Bruce

    1998-01-01

    .... We have demonstrated that technetium-99m radiolabeled human alpha-fetoprotein (99mTc AFP) localizes in human breast cancer cells in-vivo, most likely concentrating in breast cancer cells due to a specific receptor not found in normal adult breast tissue...

  4. 99MTC Alpha-Fetoprotein: A Novel, Specific Agent for the Detection of Human Breast Cancer

    National Research Council Canada - National Science Library

    Line, Bruce

    1999-01-01

    .... We have demonstrated that technetium-99m radiolabeled human alpha-fetoprotein (99mTc AFP) localizes in human breast cancer cells in-vivo, most likely concentrating in breast cancer cells due to a specific receptor not found in normal adult breast tissue...

  5. Specific Interferon-¿ detection for the diagnosis of previous Q fever

    NARCIS (Netherlands)

    Schoffelen, T.; Joosten, L.A.; Herremans, T.; Haan, A.F.J.; Ammerdorffer, A.; Rumke, H.C.; Wijkmans, C.; Roest, H.I.J.; Netea, M.G.; Meer, van der J.W.; Sprong, T.; Deuren, van M.

    2013-01-01

    BACKGROUND: Current practice for diagnosis of Q fever, caused by the intracellular pathogen Coxiella burnetii, relies mainly on serology and, in prevaccination assessment, on skin tests (STs), which both have drawbacks. In this study, C. burnetii-specific interferon ¿ (IFN-¿) production was used as

  6. Bayesian model to detect phenotype-specific genes for copy number data

    Directory of Open Access Journals (Sweden)

    González Juan R

    2012-06-01

    Full Text Available Abstract Background An important question in genetic studies is to determine those genetic variants, in particular CNVs, that are specific to different groups of individuals. This could help in elucidating differences in disease predisposition and response to pharmaceutical treatments. We propose a Bayesian model designed to analyze thousands of copy number variants (CNVs where only few of them are expected to be associated with a specific phenotype. Results The model is illustrated by analyzing three major human groups belonging to HapMap data. We also show how the model can be used to determine specific CNVs related to response to treatment in patients diagnosed with ovarian cancer. The model is also extended to address the problem of how to adjust for confounding covariates (e.g., population stratification. Through a simulation study, we show that the proposed model outperforms other approaches that are typically used to analyze this data when analyzing common copy-number polymorphisms (CNPs or complex CNVs. We have developed an R package, called bayesGen, that implements the model and estimating algorithms. Conclusions Our proposed model is useful to discover specific genetic variants when different subgroups of individuals are analyzed. The model can address studies with or without control group. By integrating all data in a unique model we can obtain a list of genes that are associated with a given phenotype as well as a different list of genes that are shared among the different subtypes of cases.

  7. Multiplex PCR for specific and robust detection of Xanthomonas campestris pv. musacearum in pure culture and infected plant material

    DEFF Research Database (Denmark)

    Adriko, John; Aritua, V.; Mortensen, Carmen Nieves

    2012-01-01

    The present study developed a pathovar-specific PCR for the detection of Xanthomonas campestris pv. musacearum (Xcm), the cause of banana xanthomonas wilt, by amplification of a 265-bp region of the gene encoding the general secretion pathway protein D (GspD). A distinct DNA fragment......-specific PCR was successfully multiplexed with internal control primers targeting 16S rDNA for application on DNA from bacterial cultures and with primers targeting plant mitochondrial 26S rDNA for application on DNA extracted from plant material. Diagnostic discrimination of healthy and infected plants...

  8. Development of surface plasmon resonance imaging for detection of Acidovorax avenae subsp. citrulli (Aac) using specific monoclonal antibody.

    Science.gov (United States)

    Puttharugsa, Chokchai; Wangkam, Thidarat; Huangkamhang, Nongluck; Gajanandana, Oraprapai; Himananto, Orawan; Sutapun, Boonsong; Amarit, Ratthasart; Somboonkaew, Armote; Srikhirin, Toemsak

    2011-01-15

    An immunosensor based on surface plasmon resonance imaging (SPR imaging) using a specific monoclonal antibody 11E5 (MAb 11E5) was developed for the detection of the seed-borne bacterium Acidovorax avenae subsp. citrulli (Aac), which causes fruit blotch in watermelons and cantaloupes, and compared to the conventional ELISA technique. The 1:40 mixed self-assembled monolayer (mixed SAM) surface was used for the immobilized MAb 11E5 on sensor surface for the detection of Aac. Both whole cells and broken cells of Aac were tested by using direct and sandwich detection assay. The limit of detection (LOD) of Aac using the SPR imaging technique and a direct detection assay was 10(6)cfu/ml and a subsequent amplification of the SPR signal using a polyclonal antibody (PAb) lowered the LOD to 5×10(5) cfu/ml. The LOD for the ELISA technique was 5×10(4) cfu/ml for the detection of Aac, which was slightly better than that for the SPR technique. However, the sensor surface based on SPR imaging offered a major advantage in terms of surface regeneration, allowing at least five cycles with a shorter time assay, multi-channel analysis with an application on multiplex detection, and an ease of the surface usage for the detection of Aac in the naturally infected plant. The surface was tested against the naturally infected sample and showed good selectivity toward the Aac bacteria. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Detection rate of prostate cancer using prostate specific antigen in patients presenting with lower urinary tract symptoms: A retrospective study

    Directory of Open Access Journals (Sweden)

    Chavan P

    2009-01-01

    Full Text Available Background: Need for undertaking prostate biopsies for detection of prostate cancer is often decided on the basis of serum levels of prostate specific antigen (PSA. Aim: To evaluate the case detection rate of prostate cancer among patients presenting with lower urinary tract symptoms (LUTS on the basis of PSA levels and to assess the scope of prostate biopsy in these patients. Setting and Design: A retrospective study from a tertiary care center. Materials and Methods: The clinical and histopathological data of 922 patients presenting with LUTS in the last five years was obtained from the medical record section. They had been screened for prostate cancer using PSA and /or digital rectal examination examination followed by confirmation with prostate biopsy. Statistical Analysis Used: Detection rate and receiver operating characteristic curve were performed using SPSS 16 and Medcalc softwares. Results: The detection rate of prostate cancer according to the PSA levels was 0.6%, 2.3%, 2.5%, 34.1% and 54.9% in the PSA range of 0-4, 4-10, 10-20, 20-50 and> 50 ng/ml, respectively. Maximum prostate cancer cases were detected beyond a PSA value of 20 ng/ml whereas no significant difference in the detection rate was observed in the PSA range of 0-4, 4-10 and 10-20 ng/ml. Conclusion: A low detection rate of prostate cancer observed in the PSA range of 4-20 ng/ml in LUTS patients indicates the need for use of higher cutoff values of PSA in such cases. Therefore we recommend a cutoff of 20 ng/ml of PSA for evaluation of detection rate of prostate cancer among patients presenting with LUTS.

  10. Development of a bead-based Luminex assay using lipopolysaccharide specific monoclonal antibodies to detect biological threats from Brucella species.

    Science.gov (United States)

    Silbereisen, Angelika; Tamborrini, Marco; Wittwer, Matthias; Schürch, Nadia; Pluschke, Gerd

    2015-10-05

    Brucella, a Gram-negative bacterium, is classified as a potential bioterrorism agent mainly due to the low dose needed to cause infection and the ability to transmit the bacteria via aerosols. Goats/sheep, cattle, pigs, dogs, sheep and rodents are infected by B. melitensis, B. abortus, B. suis, B. canis, B. ovis and B. neotomae, respectively, the six classical Brucella species. Most human cases are caused by B. melitensis and B. abortus. Our aim was to specifically detect Brucellae with 'smooth' lipopolysaccharide (LPS) using a highly sensitive monoclonal antibody (mAb) based immunological assay. To complement molecular detection systems for potential bioterror agents, as required by international biodefense regulations, sets of mAbs were generated by B cell hybridoma technology and used to develop immunological assays. The combination of mAbs most suitable for an antigen capture assay format was identified and an immunoassay using the Luminex xMAP technology was developed. MAbs specific for the LPS O-antigen of Brucella spp. were generated by immunising mice with inactivated B. melitensis or B. abortus cells. Most mAbs recognised both B. melitensis and B. abortus and antigen binding was not impeded by inactivation of the bacterial cells by γ irradiation, formalin or heat treatment, a step required to analyse the samples immunologically under biosafety level two conditions. The Luminex assay recognised all tested Brucella species with 'smooth' LPS with detection limits of 2×10(2) to 8×10(4) cells per mL, depending on the species tested. Milk samples spiked with Brucella spp. cells were identified successfully using the Luminex assay. In addition, the bead-based immunoassay was integrated into a multiplex format, allowing for simultaneous, rapid and specific detection of Brucella spp., Bacillus anthracis, Francisella tularensis and Yersinia pestis within a single sample. Overall, the robust Luminex assay should allow detection of Brucella spp. in both natural

  11. Specific, sensitive, high-resolution detection of protein molecules in eukaryotic cells using metal-tagging transmission electron microscopy

    Science.gov (United States)

    Risco, Cristina; Sanmartín-Conesa, Eva; Tzeng, Wen-Pin; Frey, Teryl K.; Seybold, Volker; de Groot, Raoul J.

    2012-01-01

    Summary More than any other methodology, transmission electron microscopy (TEM) has contributed to our understanding of the architecture and organization of cells. With current detection limits approaching atomic resolution, it will ultimately become possible to ultrastructurally image intracellular macromolecular assemblies in situ. Presently, however, methods to unambiguously identify proteins within the crowded environment of the cell’s interior are lagging behind. We describe a novel approach, metal-tagging TEM (METTEM) that allows detection of intracellular proteins in mammalian cells with high specificity, exceptional sensitivity and at molecular scale resolution. In live cells treated with gold salts, proteins bearing a small metal-binding tag will form 1-nm gold nanoclusters, readily detectable in electron micrographs. The applicability and strength of METTEM is demonstrated by a study of Rubella virus replicase and capsid proteins, which revealed virus-induced cell structures not seen before. PMID:22579245

  12. High Sensitivity and High Detection Specificity of Gold-Nanoparticle-Grafted Nanostructured Silicon Mass Spectrometry for Glucose Analysis.

    Science.gov (United States)

    Tsao, Chia-Wen; Yang, Zhi-Jie

    2015-10-14

    Desorption/ionization on silicon (DIOS) is a high-performance matrix-free mass spectrometry (MS) analysis method that involves using silicon nanostructures as a matrix for MS desorption/ionization. In this study, gold nanoparticles grafted onto a nanostructured silicon (AuNPs-nSi) surface were demonstrated as a DIOS-MS analysis approach with high sensitivity and high detection specificity for glucose detection. A glucose sample deposited on the AuNPs-nSi surface was directly catalyzed to negatively charged gluconic acid molecules on a single AuNPs-nSi chip for MS analysis. The AuNPs-nSi surface was fabricated using two electroless deposition steps and one electroless etching step. The effects of the electroless fabrication parameters on the glucose detection efficiency were evaluated. Practical application of AuNPs-nSi MS glucose analysis in urine samples was also demonstrated in this study.

  13. Specific PCR detection of Fusarium oxysporum f. sp. raphani: a causal agent of Fusarium wilt on radish plants.

    Science.gov (United States)

    Kim, H; Hwang, S-M; Lee, J H; Oh, M; Han, J W; Choi, G J

    2017-08-01

    Fusarium oxysporum, a causal agent of Fusarium wilt, is one of the most important fungal pathogens worldwide, and detection of F. oxysporum DNA at the forma specialis level is crucial for disease diagnosis and control. In this study, two novel F. oxysporum f. sp. raphani (For)-specific primer sets were designed, FOR1-F/FOR1-R and FOR2-F/FOR2-R, to target FOQG_17868 and FOQG_17869 ORFs, respectively, which were selected based on the genome comparison of other formae speciales of F. oxysporum including conglutinans, cubense, lycopersici, melonis, and pisi. The primer sets FOR1-F/FOR1-R and FOR2-F/FOR2-R that amplified a 610- and 425-bp DNA fragment, respectively, were specific to For isolates which was confirmed using a total of 40 F. oxysporum isolates. From infected plants, the FOR2-F/FOR2-R primer set directly detected the DNA fragment of For isolates even when the radish plants were collected in their early stage of disease development. Although the loci targeted by the For-specific primer sets were not likely involved in the pathogenesis, the primer set FOR2-F/FOR2-R is available for the determination of pathogenicity of radish-infecting F. oxysporum isolates. This study is the first report providing novel primer sets to detect F. oxysporum f. sp. raphani. Because plant pathogenic Fusarium oxysporum has been classified into special forms based on its host specificity, identification of F. oxysporum usually requires a pathogenicity assay as well as knowledge of the morphological characteristics. For rapid and reliable diagnosis, this study provides PCR primer sets that specifically detect Fusarium oxysporum f. sp. raphani (For) which is a devastating pathogen of radish plants. Because one of the primer sets directly detected the DNA fragment of For isolates from infected plants, the specific PCR method demonstrated in this study will provide a foundation for integrated disease management practices in commodity crops. © 2017 The Society for Applied Microbiology.

  14. Specification for a surface-search radar-detection-range model

    Science.gov (United States)

    Hattan, Claude P.

    1990-09-01

    A model that predicts surface-search radar detection range versus a variety of combatants has been developed at the Naval Ocean Systems Center. This model uses a simplified ship radar cross section (RCS) model and the U.S. Navy Oceanographic and Atmospheric Mission Library Standard Electromagnetic Propagation Model. It provides the user with a method of assessing the effects of the environment of the performance of a surface-search radar system. The software implementation of the model is written in ANSI FORTRAN 77, with MIL-STD-1753 extensions. The program provides the user with a table of expected detection ranges when the model is supplied with the proper environmental radar system inputs. The target model includes the variation in RCS as a function of aspect angle and the distribution of reflected radar energy as a function of height above the waterline. The modeled propagation effects include refraction caused by a multisegmented refractivity profile, sea-surface roughness caused by local winds, evaporation ducting, and surface-based ducts caused by atmospheric layering.

  15. Specific detection of Vibrio parahaemolyticus by fluorescence quenching immunoassay based on quantum dots.

    Science.gov (United States)

    Wang, Ling; Zhang, Junxian; Bai, Haili; Li, Xuan; Lv, Pintian; Guo, Ailing

    2014-07-01

    In this study, anti-Vibrio parahaemolyticus polyclonal and monoclonal antibodies were prepared through intradermal injection immune and lymphocyte hybridoma technique respectively. CdTe quantum dots (QDs) were synthesized at pH 9.3, 98 °C for 1 h with stabilizer of 2.7:1. The fluorescence intensity was 586.499, and the yield was 62.43%. QD probes were successfully prepared under the optimized conditions of pH 7.4, 37 °C for 1 h, 250 μL of 50 mg/mL EDC · HCl, 150 μL of 4 mg/mL NHS, buffer system of Na2HPO4-citric acid, and 8 μL of 2.48 mg/mL polyclonal antibodies. As gold nanoparticles could quench fluorescence of quantum dots, the concentration of V. parahaemolyticus could be detected through measuring the reduction of fluorescence intensity in immune sandwich reaction composed of quantum dot probe, gold-labeled antibody, and the sample. For pure culture, fluorescence intensity of the system was proportional with logarithm concentration of antigen, and the correlation coefficient was 99.764%. The fluorescence quenching immunoassay based on quantum dots is established for the first time to detect Vibrio parahaemolyticus. This method may be used as rapid testing procedure due to its high simplicity and sensitivity.

  16. Quantitative detection of nitroxyl upon trapping with glutathione and labeling with a specific fluorogenic reagent.

    Science.gov (United States)

    Johnson, Gail M; Chozinski, Tyler J; Salmon, Debra J; Moghaddam, Alan D; Chen, Hsin Chih; Miranda, Katrina M

    2013-10-01

    Donors of nitroxyl (HNO) have shown promise for treatment of stroke, heart failure, alcoholism and cancer. However, comparing the pharmacological capacities of various donors is difficult without first quantifying the amount of HNO released from each donor. Detection and quantitation of HNO has been complicated by the rapid self-consumption of HNO through irreversible dimerization, poor selectivity of trapping agents against other nitrogen oxides, and/or low sensitivity towards HNO. Here, an assay is described for the trapping of HNO by glutathione (GSH) followed by labeling of GSH with the fluorogenic agent, naphthalene-2,3-dicarboxaldehyde (NDA), and subsequent quantitation by fluorescence difference. The newly developed assay was used to validate the pH-dependence of HNO release from isopropylamine NONOate (IPA/NO), which is a dual donor of HNO and NO at physiological pH. Furthermore, varied assay conditions were utilized to suggest the ratios of the products of the reaction of GSH with HNO. At intracellular concentrations of GSH, the disulfide (GSSG) was the major product, but significant concentrations of glutathione sulfinamide (GS(O)NH₂) were also detected. This suggests that GS(O)NH₂, which is a selective biomarker of HNO, may be produced in concentrations that are amenable to in vivo analysis. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Specific bioanalytical optical and photoelectrochemical assays for detection of methanol in alcoholic beverages.

    Science.gov (United States)

    Barroso, Javier; Díez-Buitrago, Beatriz; Saa, Laura; Möller, Marco; Briz, Nerea; Pavlov, Valeri

    2018-03-15

    Methanol is a poison which is frequently discovered in alcoholic beverages. Innovative methods to detect methanol in alcoholic beverages are being constantly developed. We report for the first time a new strategy for the detection of methanol using fluorescence spectroscopy and photoelectrochemical (PEC) analysis. The analytical system is based on the oxidation of cysteine (CSH) with hydrogen peroxide (H 2 O 2 ) enzymatically generated by alcohol oxidase (AOx). H 2 O 2 oxidizes capping agent CSH, modulating the growth of CSH-stabilized cadmium sulphide quantum dots (CdS QDs). Disposable screen-printed carbon electrodes (SPCEs) modified with a conductive osmium polymer (Os-PVP) complex were employed to quantify resulting CdS QDs. This polymer facilitates the "wiring" of in situ enzymatically generated CdS QDs, which photocatalyze oxidation of 1-thioglycerol (TG), generating photocurrent as the readout signal. Likewise, we proved that our systems did not suffer from interference by ethanol. The PEC assays showed better sensitivity than conventional methods, covering a wide range of potential applications for methanol quantification. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Detection of cerebrospinal fluid leakage by specific measurement of transferrin glycoforms.

    Science.gov (United States)

    Kwon, Seok-Joon; Zhang, Fuming; Dordick, Jonathan S; Sonstein, William J; Linhardt, Robert J

    2015-10-01

    A simple and rapid detection of cerebrospinal fluid (CSF) leakage would benefit spine surgeons making critical postoperative decisions on patient care. We have assessed novel approaches to selectively determine CSF β2-transferrin (β2TF), an asialo-transferrin (aTF) biomarker, without interference from serum sialo-transferrin (sTF) in test samples. First, we performed mild periodate oxidation to selectively generate aldehyde groups in sTF for capture with magnetic hydrazide microparticles, and selective removal with a magnetic separator. Using this protocol sTF was selectively removed from mixtures of CSF and serum containing CSF aTF (β2TF) and serum sTF, respectively. Second, a two-step enzymatic method was developed with neuraminidase and galactose oxidase for generating aldehyde groups in sTF present in CSF and serum mixtures for magnetic hydrazide microparticle capture. After selectively removing sTF from mixtures of CSF and serum, ELISA could detect significant TF signal only in CSF, while the TF signal in serum was negligible. The new approach for selective removal of only sTF in test samples will be promising for the required intervention by a spine surgeon. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Enhanced subject-specific resting-state network detection and extraction with fast fMRI.

    Science.gov (United States)

    Akin, Burak; Lee, Hsu-Lei; Hennig, Jürgen; LeVan, Pierre

    2017-02-01

    Resting-state networks have become an important tool for the study of brain function. An ultra-fast imaging technique that allows to measure brain function, called Magnetic Resonance Encephalography (MREG), achieves an order of magnitude higher temporal resolution than standard echo-planar imaging (EPI). This new sequence helps to correct physiological artifacts and improves the sensitivity of the fMRI analysis. In this study, EPI is compared with MREG in terms of capability to extract resting-state networks. Healthy controls underwent two consecutive resting-state scans, one with EPI and the other with MREG. Subject-level independent component analyses (ICA) were performed separately for each of the two datasets. Using Stanford FIND atlas parcels as network templates, the presence of ICA maps corresponding to each network was quantified in each subject. The number of detected individual networks was significantly higher in the MREG data set than for EPI. Moreover, using short time segments of MREG data, such as 50 seconds, one can still detect and track consistent networks. Fast fMRI thus results in an increased capability to extract distinct functional regions at the individual subject level for the same scan times, and also allow the extraction of consistent networks within shorter time intervals than when using EPI, which is notably relevant for the analysis of dynamic functional connectivity fluctuations. Hum Brain Mapp 38:817-830, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  20. Improvement of western blot test specificity for detecting equine serum antibodies to Sarcocystis neurona.

    Science.gov (United States)

    Rossano, M G; Mansfield, L S; Kaneene, J B; Murphy, A J; Brown, C M; Schott, H C; Fox, J C

    2000-01-01

    Equine protozoal myeloencephalitis (EPM) is a neurological disease of horses and ponies caused by the apicomplexan protozoan parasite Sarcocystis neurona. The purposes of this study were to develop the most stringent criteria possible for a positive test result, to estimate the sensitivity and specificity of the EPM Western blot antibody test, and to assess the ability of bovine antibodies to Sarcocystis cruzi to act as a blocking agent to minimize false-positive results in the western blot test for S. neurona. Sarcocystis neurona merozoites harvested from equine dermal cell culture were heat denatured, and the proteins were separated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis in a 12-20% linear gradient gel. Separated proteins were electrophoretically transferred to polyvinylidene fluoride membranes and blocked in 1% bovine serum albumin and 0.5% Tween-Tris-buffered saline. Serum samples from 6 horses with S. neurona infections (confirmed by culture from neural tissue) and 57 horses without infections (horses from the Eastern Hemisphere, where S. neurona does not exist) were tested by Western blot. Horses from both groups had reactivity to the 62-, 30-, 16-, 13-, 11-, 10.5-, and 10-kD bands. Testing was repeated with another step. Blots were treated with bovine S. cruzi antibodies prior to loading the equine samples. After this modification of the Western blot test, positive infection status was significantly associated with reactivity to the 30- and 16-kD bands (Pblot had a sample sensitivity of 100% and sample specificity of 98%. It is concluded that the specificity of the Western blot test is improved by blocking proteins not specific to S. neurona and using reactivity to the 30- and 16-kD bands as the criterion for a positive test.

  1. A method for the specific detection of resident bacteria in brine shrimp larvae.

    Science.gov (United States)

    Niu, Yufeng; Defoirdt, Tom; Rekecki, Anamaria; De Schryver, Peter; Van den Broeck, Wim; Dong, Shuanglin; Sorgeloos, Patrick; Boon, Nico; Bossier, Peter

    2012-04-01

    In this study, we describe an easy but efficient method to specifically target the intestinal resident microbiota in brine shrimp larvae during DGGE analysis, hereby excluding the interference of both transient (luminal) bacteria and body surface bacteria. This effective technique has several advantages over alternative methods, with respect of ease of use and rapidity. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Development of a Sensitive and Specific Antigen-Detection System for Strongyloides Stercoralis and Hookworm Infections

    Science.gov (United States)

    1997-06-01

    difficult to specifically identify, and failure to implement the correct antibiotic therapy in a timely fashion can result in the onset of acute symptoms...compromised patients are particularly at risk. Treatment is similar to hookworms. Treatment of nematode infection is fairly standard with therapies using...caninum eggs harvested by floatation in ZnSO 4 solution were similarly processed for PAGE fractionation except that eggs were not homogenized. Figures 13a

  3. Trajectory Specification for Terminal Air Traffic: Pairwise Conflict Detection and Resolution

    Science.gov (United States)

    Paielli, Russ; Erzberger, Heinz

    2017-01-01

    Trajectory specification is the explicit bounding and control of aircraft trajectories such that the position at each point in time is constrained to a precisely defined volume of space. The bounding space is defined by cross-track, along-track, and vertical tolerances relative to a reference trajectory that specifies position as a function of time. The tolerances are dynamic and will be based on the aircraft navigation capabilities and the current traffic situation. A standard language will be developed to represent these specifications and to communicate them by datalink. Assuming conformance, trajectory specification can guarantee safe separation for an arbitrary period of time even in the event of an air traffic control (ATC) system or datalink failure, hence it can help to achieve the high level of safety and reliability needed for ATC automation. As a more proactive form of ATC, it can also maximize airspace capacity and reduce the reliance on tactical backup systems during normal operation. It applies to both enroute airspace and the terminal area around airports, but this paper focuses on the terminal area and presents algorithms and software for spacing arrivals and deconflicting both arrivals and departures.

  4. Development and validation of Burkholderia pseudomallei-specific real-time PCR assays for clinical, environmental or forensic detection applications.

    Directory of Open Access Journals (Sweden)

    Erin P Price

    Full Text Available The bacterium Burkholderia pseudomallei causes melioidosis, a rare but serious illness that can be fatal if untreated or misdiagnosed. Species-specific PCR assays provide a technically simple method for differentiating B. pseudomallei from near-neighbor species. However, substantial genetic diversity and high levels of recombination within this species reduce the likelihood that molecular signatures will differentiate all B. pseudomallei from other Burkholderiaceae. Currently available molecular assays for B. pseudomallei detection lack rigorous validation across large in silico datasets and isolate collections to test for specificity, and none have been subjected to stringent quality control criteria (accuracy, precision, selectivity, limit of quantitation (LoQ, limit of detection (LoD, linearity, ruggedness and robustness to determine their suitability for environmental, clinical or forensic investigations. In this study, we developed two novel B. pseudomallei specific assays, 122018 and 266152, using a dual-probe approach to differentiate B. pseudomallei from B. thailandensis, B. oklahomensis and B. thailandensis-like species; other species failed to amplify. Species specificity was validated across a large DNA panel (>2,300 samples comprising Burkholderia spp. and non-Burkholderia bacterial and fungal species of clinical and environmental relevance. Comparison of assay specificity to two previously published B. pseudomallei-specific assays, BurkDiff and TTS1, demonstrated comparable performance of all assays, providing between 99.7 and 100% specificity against our isolate panel. Last, we subjected 122018 and 266152 to rigorous quality control analyses, thus providing quantitative limits of assay performance. Using B. pseudomallei as a model, our study provides a framework for comprehensive quantitative validation of molecular assays and provides additional, highly validated B. pseudomallei assays for the scientific research community.

  5. A label-free aptamer-fluorophore assembly for rapid and specific detection of cocaine in biofluids.

    Science.gov (United States)

    Roncancio, Daniel; Yu, Haixiang; Xu, Xiaowen; Wu, Shuo; Liu, Ran; Debord, Joshua; Lou, Xinhui; Xiao, Yi

    2014-11-18

    We report a rapid and specific aptamer-based method for one-step cocaine detection with minimal reagent requirements. The feasibility of aptamer-based detection has been demonstrated with sensors that operate via target-induced conformational change mechanisms, but these have generally exhibited limited target sensitivity. We have discovered that the cocaine-binding aptamer MNS-4.1 can also bind the fluorescent molecule 2-amino-5,6,7-trimethyl-1,8-naphthyridine (ATMND) and thereby quench its fluorescence. We subsequently introduced sequence changes into MNS-4.1 to engineer a new cocaine-binding aptamer (38-GC) that exhibits higher affinity to both ligands, with reduced background signal and increased signal gain. Using this aptamer, we have developed a new sensor platform that relies on the cocaine-mediated displacement of ATMND from 38-GC as a result of competitive binding. We demonstrate that our sensor can detect cocaine within seconds at concentrations as low as 200 nM, which is 50-fold lower than existing assays based on target-induced conformational change. More importantly, our assay achieves successful cocaine detection in body fluids, with a limit of detection of 10.4, 18.4, and 36 μM in undiluted saliva, urine, and serum samples, respectively.

  6. A nanoparticle label/immunochromatographic electrochemical biosensor for rapid and sensitive detection of prostate-specific antigen

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Ying-Ying; Wang, Jun; Liu, Guodong; Wu, Hong; Wai, Chien M.; Lin, Yuehe

    2008-06-15

    We present a nanoparticle (NP) label/immunochromatographic electrochemical biosensor (IEB) for rapid and sensitive detection of prostate-specific antigen (PSA) in human serum. This IEB integrates the immunochromatographic strip with the electrochemical detector for transducing quantitative signals. The NP label, made of CdSe@ZnS, serves as a signal-amplifier vehicle. A sandwich immunoreaction was performed on the immunochromatographic strip. The captured NP labels in the test zone were determined by highly sensitive stripping voltammetric measurement of the dissolved metallic component (cadmium) with a disposable-screen-printed electrode, which is embedded underneath the membrane of the test zone. Experimental parameters (e.g., immunoreaction time, the amount of anti-PSA-NP conjugations applied) and electrochemical detection conditions (e.g., preconcentration potential and time) were optimized using this biosensor for PSA detection. The analytical performance of this biosensor was evaluated with serum PSA samples according to the “figure-of-merits” (e.g., dynamic range, reproducibility, and detection limit). The results were validated with enzyme-linked immunosorbent assay (ELISA) and show high consistency. It is found that this biosensor is very sensitive with the detection limit of 0.02 ng/mL PSA and is quite reproducible. This method is rapid, clinically accurate, and less expensive than other diagnosis tools for PSA; therefore, this IEB coupled with a portable electrochemical analyzer shows great promise for simple, sensitive, quantitative point-of-care testing of disease-related protein biomarkers.

  7. Sensitive and substrate-specific detection of metabolically active microorganisms in natural microbial consortia using community isotope arrays.

    Science.gov (United States)

    Tourlousse, Dieter M; Kurisu, Futoshi; Tobino, Tomohiro; Furumai, Hiroaki

    2013-05-01

    The goal of this study was to develop and validate a novel fosmid-clone-based metagenome isotope array approach - termed the community isotope array (CIArray) - for sensitive detection and identification of microorganisms assimilating a radiolabeled substrate within complex microbial communities. More specifically, a sample-specific CIArray was used to identify anoxic phenol-degrading microorganisms in activated sludge treating synthetic coke-oven wastewater in a single-sludge predenitrification-nitrification process. Hybridization of the CIArray with DNA from the (14) C-phenol-amended sample indicated that bacteria assimilating (14) C-atoms, presumably directly from phenol, under nitrate-reducing conditions were abundant in the reactor, and taxonomic assignment of the fosmid clone end sequences suggested that they belonged to the Gammaproteobacteria. The specificity of the CIArray was validated by quantification of fosmid-clone-specific DNA in density-resolved DNA fractions from samples incubated with (13) C-phenol, which verified that all CIArray-positive probes stemmed from microorganisms that assimilated isotopically labeled carbon. This also demonstrated that the CIArray was more sensitive than DNA-SIP, as the former enabled positive detection at a phenol concentration that failed to yield a 'heavy' DNA fraction. Finally, two operational taxonomic units distantly related to marine Gammaproteobacteria were identified to account for more than half of 16S rRNA gene clones in the 'heavy' DNA library, corroborating the CIArray-based identification. © 2013 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.

  8. Specificity of the Linear Array HPV Genotyping Test for detecting human papillomavirus genotype 52 (HPV-52)

    OpenAIRE

    Kocjan, Boštjan; Poljak, Mario; Oštrbenk, Anja

    2015-01-01

    Introduction: HPV-52 is one of the most frequent human papillomavirus (HPV) genotypes causing significant cervical pathology. The most widely used HPV genotyping assay, the Roche Linear Array HPV Genotyping Test (Linear Array), is unable to identify HPV- 52 status in samples containing HPV-33, HPV-35, and/or HPV-58. Methods: Linear Array HPV-52 analytical specificity was established by testing 100 specimens reactive with the Linear Array HPV- 33/35/52/58 cross-reactive probe, but not with the...

  9. Enzyme-linked immunosorbent assays for detection of equine antibodies specific to Sarcocystis neurona surface antigens.

    Science.gov (United States)

    Hoane, Jessica S; Morrow, Jennifer K; Saville, William J; Dubey, J P; Granstrom, David E; Howe, Daniel K

    2005-09-01

    Sarcocystis neurona is the primary causative agent of equine protozoal myeloencephalitis (EPM), a common neurologic disease of horses in the Americas. We have developed a set of enzyme-linked immunosorbent assays (ELISAs) based on the four major surface antigens of S. neurona (SnSAGs) to analyze the equine antibody response to S. neurona. The SnSAG ELISAs were optimized and standardized with a sample set of 36 equine sera that had been characterized by Western blotting against total S. neurona parasite antigen, the current gold standard for S. neurona serology. The recombinant SnSAG2 (rSnSAG2) ELISA showed the highest sensitivity and specificity at 95.5% and 92.9%, respectively. In contrast, only 68.2% sensitivity and 71.4% specificity were achieved with the rSnSAG1 ELISA, indicating that this antigen may not be a reliable serological marker for analyzing antibodies against S. neurona in horses. Importantly, the ELISA antigens did not show cross-reactivity with antisera to Sarcocystis fayeri or Neospora hughesi, two other equine parasites. The accuracy and reliability exhibited by the SnSAG ELISAs suggest that these assays will be valuable tools for examining the equine immune response against S. neurona infection, which may help in understanding the pathobiology of this accidental parasite-host interaction. Moreover, with modification and further investigation, the SnSAG ELISAs have potential for use as immunodiagnostic tests to aid in the identification of horses affected by EPM.

  10. Enzyme-Linked Immunosorbent Assays for Detection of Equine Antibodies Specific to Sarcocystis neurona Surface Antigens†

    Science.gov (United States)

    Hoane, Jessica S.; Morrow, Jennifer K.; Saville, William J.; Dubey, J. P.; Granstrom, David E.; Howe, Daniel K.

    2005-01-01

    Sarcocystis neurona is the primary causative agent of equine protozoal myeloencephalitis (EPM), a common neurologic disease of horses in the Americas. We have developed a set of enzyme-linked immunosorbent assays (ELISAs) based on the four major surface antigens of S. neurona (SnSAGs) to analyze the equine antibody response to S. neurona. The SnSAG ELISAs were optimized and standardized with a sample set of 36 equine sera that had been characterized by Western blotting against total S. neurona parasite antigen, the current gold standard for S. neurona serology. The recombinant SnSAG2 (rSnSAG2) ELISA showed the highest sensitivity and specificity at 95.5% and 92.9%, respectively. In contrast, only 68.2% sensitivity and 71.4% specificity were achieved with the rSnSAG1 ELISA, indicating that this antigen may not be a reliable serological marker for analyzing antibodies against S. neurona in horses. Importantly, the ELISA antigens did not show cross-reactivity with antisera to Sarcocystis fayeri or Neospora hughesi, two other equine parasites. The accuracy and reliability exhibited by the SnSAG ELISAs suggest that these assays will be valuable tools for examining the equine immune response against S. neurona infection, which may help in understanding the pathobiology of this accidental parasite-host interaction. Moreover, with modification and further investigation, the SnSAG ELISAs have potential for use as immunodiagnostic tests to aid in the identification of horses affected by EPM. PMID:16148170

  11. Microfluidic-integrated patterned ITO immunosensor for rapid detection of prostate-specific membrane antigen biomarker in prostate cancer.

    Science.gov (United States)

    Seenivasan, Rajesh; Singh, Chandra K; Warrick, Jay W; Ahmad, Nihal; Gunasekaran, Sundaram

    2017-09-15

    An optically transparent patterned indium tin oxide (ITO) three-electrode sensor integrated with a microfluidic channel was designed for label-free immunosensing of prostate-specific membrane antigen (PSMA), a prostate cancer (PCa) biomarker, expressed on prostate tissue and circulating tumor cells but also found in serum. The sensor relies on cysteamine capped gold nanoparticles (N-AuNPs) covalently linked with anti-PSMA antibody (Ab) for target specificity. A polydimethylsiloxane (PDMS) microfluidic channel is used to efficiently and reproducibly introduce sample containing soluble proteins/cells to the sensor. The PSMA is detected and quantified by measuring the change in differential pulse voltammetry signal of a redox probe ([Fe(CN) 6 ] 3- /[Fe(CN) 6 ] 4- ) that is altered upon binding of PSMA with PSMA-Ab immobilized on N-AuNPs/ITO. Detection of PSMA expressing cells and soluble PSMA was tested. The limit of detection (LOD) of the sensor for PSMA-based PCa cells is 6/40µL (i.e., 150 cells/mL) (n=3) with a linear range of 15-400 cells/40µL (i.e., 375-10,000 cells/mL), and for the soluble PSMA is 0.499ng/40µL (i.e., 12.5ng/mL) (n=3) with the linear range of 0.75-250ng/40µL (i.e., 19-6250ng/mL), both with an incubation time of 10min. The results indicate that the sensor has a suitable sensitivity and dynamic range for routine detection of PCa circulating tumor cells and can be adapted to detect other biomarkers/cancer cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Specificity and Strain-Typing Capabilities of Nanorod Array-Surface Enhanced Raman Spectroscopy for Mycoplasma pneumoniae Detection.

    Directory of Open Access Journals (Sweden)

    Kelley C Henderson

    Full Text Available Mycoplasma pneumoniae is a cell wall-less bacterial pathogen of the human respiratory tract that accounts for > 20% of all community-acquired pneumonia (CAP. At present the most effective means for detection and strain-typing is quantitative polymerase chain reaction (qPCR, which can exhibit excellent sensitivity and specificity but requires separate tests for detection and genotyping, lacks standardization between available tests and between labs, and has limited practicality for widespread, point-of-care use. We have developed and previously described a silver nanorod array-surface enhanced Raman Spectroscopy (NA-SERS biosensing platform capable of detecting M. pneumoniae with statistically significant specificity and sensitivity in simulated and true clinical throat swab samples, and the ability to distinguish between reference strains of the two main genotypes of M. pneumoniae. Furthermore, we have established a qualitative lower endpoint of detection for NA-SERS of < 1 genome equivalent (cell/μl and a quantitative multivariate detection limit of 5.3 ± 1 cells/μl. Here we demonstrate using partial least squares- discriminatory analysis (PLS-DA of sample spectra that NA-SERS correctly identified M. pneumoniae clinical isolates from globally diverse origins and distinguished these from a panel of 12 other human commensal and pathogenic mycoplasma species with 100% cross-validated statistical accuracy. Furthermore, PLS-DA correctly classified by strain type all 30 clinical isolates with 96% cross-validated accuracy for type 1 strains, 98% cross-validated accuracy for type 2 strains, and 90% cross-validated accuracy for type 2V strains.

  13. Phase-specific Surround suppression in Mouse Primary Visual Cortex Correlates with Figure Detection Behavior Based on Phase Discontinuity.

    Science.gov (United States)

    Li, Fengling; Jiang, Weiqian; Wang, Tian-Yi; Xie, Taorong; Yao, Haishan

    2018-05-21

    In the primary visual cortex (V1), neuronal responses to stimuli within the receptive field (RF) are modulated by stimuli in the RF surround. A common effect of surround modulation is surround suppression, which is dependent on the feature difference between stimuli within and surround the RF and is suggested to be involved in the perceptual phenomenon of figure-ground segregation. In this study, we examined the relationship between feature-specific surround suppression of V1 neurons and figure detection behavior based on figure-ground feature difference. We trained freely moving mice to perform a figure detection task using figure and ground gratings that differed in spatial phase. The performance of figure detection increased with the figure-ground phase difference, and was modulated by stimulus contrast. Electrophysiological recordings from V1 in head-fixed mice showed that the increase in phase difference between stimuli within and surround the RF caused a reduction in surround suppression, which was associated with an increase in V1 neural discrimination between stimuli with and without RF-surround phase difference. Consistent with the behavioral performance, the sensitivity of V1 neurons to RF-surround phase difference could be influenced by stimulus contrast. Furthermore, inhibiting V1 by optogenetically activating either parvalbumin (PV)- or somatostatin (SOM)-expressing inhibitory neurons both decreased the behavioral performance of figure detection. Thus, the phase-specific surround suppression in V1 represents a neural correlate of figure detection behavior based on figure-ground phase discontinuity. Copyright © 2018 IBRO. Published by Elsevier Ltd. All rights reserved.

  14. Specific capture and detection of Staphylococcus aureus with high-affinity modified aptamers to cell surface components.

    Science.gov (United States)

    Baumstummler, A; Lehmann, D; Janjic, N; Ochsner, U A

    2014-10-01

    Slow off-rate modified aptamer (SOMAmer) reagents were generated to several Staphylococcus aureus cell surface-associated proteins via SELEX with multiple modified DNA libraries using purified recombinant or native proteins. High-affinity binding agents with sub-nanomolar Kd 's were obtained for staphylococcal protein A (SpA), clumping factors (ClfA, ClfB), fibronectin-binding proteins (FnbA, FnbB) and iron-regulated surface determinants (Isd). Further screening revealed several SOMAmers that specifically bound to Staph. aureus cells from all strains that were tested, but not to other staphylococci or other bacteria. SpA and ClfA SOMAmers proved useful for the selective capture and enrichment of Staph. aureus cells, as shown by culture and PCR, leading to improved limits of detection and efficient removal of PCR inhibitors. Detection of Staph. aureus cells was enhanced by several orders of magnitude when the bacterial cell surface was coated with SOMAmers followed by qPCR of the SOMAmers. Furthermore, fluorescence-labelled SpA SOMAmers demonstrated their utility as direct detection agents in flow cytometry. Significance and impact of the study: Monitoring for microbial contamination of food, water, nonsterile products or the environment is typically based on culture, PCR or antibodies. Aptamers that bind with high specificity and affinity to well-conserved cell surface epitopes represent a promising novel type of reagents to detect bacterial cells without the need for culture or cell lysis, including for the capture and enrichment of bacteria present at low cell densities and for the direct detection via qPCR or fluorescent staining. © 2014 Soma Logic, Inc. published by John Wiley & Sons Ltd On behalf of the society for Applied Microbiology.

  15. Sensitivity and Specificity of the Coma Recovery Scale--Revised Total Score in Detection of Conscious Awareness.

    Science.gov (United States)

    Bodien, Yelena G; Carlowicz, Cecilia A; Chatelle, Camille; Giacino, Joseph T

    2016-03-01

    To describe the sensitivity and specificity of Coma Recovery Scale-Revised (CRS-R) total scores in detecting conscious awareness. Data were retrospectively extracted from the medical records of patients enrolled in a specialized disorders of consciousness (DOC) program. Sensitivity and specificity analyses were completed using CRS-R-derived diagnoses of minimally conscious state (MCS) or emerged from minimally conscious state (EMCS) as the reference standard for conscious awareness and the total CRS-R score as the test criterion. A receiver operating characteristic curve was constructed to demonstrate the optimal CRS-R total cutoff score for maximizing sensitivity and specificity. Specialized DOC program. Patients enrolled in the DOC program (N=252, 157 men; mean age, 49y; mean time from injury, 48d; traumatic etiology, n=127; nontraumatic etiology, n=125; diagnosis of coma or vegetative state, n=70; diagnosis of MCS or EMCS, n=182). Not applicable. Sensitivity and specificity of CRS-R total scores in detecting conscious awareness. A CRS-R total score of 10 or higher yielded a sensitivity of .78 for correct identification of patients in MCS or EMCS, and a specificity of 1.00 for correct identification of patients who did not meet criteria for either of these diagnoses (ie, were diagnosed with vegetative state or coma). The area under the curve in the receiver operating characteristic curve analysis is .98. A total CRS-R score of 10 or higher provides strong evidence of conscious awareness but resulted in a false-negative diagnostic error in 22% of patients who demonstrated conscious awareness based on CRS-R diagnostic criteria. A cutoff score of 8 provides the best balance between sensitivity and specificity, accurately classifying 93% of cases. The optimal total score cutoff will vary depending on the user's objective. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  16. Overall survival after prostate-specific-antigen-detected recurrence following conformal radiation therapy

    International Nuclear Information System (INIS)

    Sandler, Howard M.; Dunn, Rodney L.; McLaughlin, P. William; Hayman, James A.; Sullivan, Molly A.; Taylor, Jeremy M.G.

    2000-01-01

    Purpose: To study the significance, in terms of overall and cause-specific survival, of biochemical failure after conformal external-beam radiation therapy (RT) for prostate cancer. Methods and Materials: Of the 1844 patients in the Radiation Oncology prostate cancer database, 718 were deemed eligible. Patients excluded were those with N1 or M1 disease, those treated after radical prostatectomy, those who received hormone therapy before radiation therapy, and those who died, failed clinically, or had no PSA response in the first 6 months after RT. Patients included were required to have a minimum of 2 post-RT PSAs separated by at least 1 week. Biochemical relapse was defined as 3 consecutive PSA rises. This resulted in 154 patients with biochemical failure. Survival was calculated from the third PSA elevation. The rate of rise of PSA was calculated by fitting a regression line to the four rising PSAs on a ln PSA vs. time plot. Results: There were 41 deaths among the 154 patients with failure in 23 of the 41 due to prostate cancer. The overall survival after failure was 58% at 5 years, while the cause-specific failure was 73% at 5 years. Among the 154 failures, several factors were evaluated for an association with overall survival: age at failure, pre-RT PSA, PSA at second rise, PSA nadir, time from RT to failure, time to nadir, Gleason score, T-stage, and rate of rise, both from the nadir and from the beginning of the rise. None of these factors were significantly associated with an increased risk of death. As expected, the group of patients with biochemical failure have significantly worse prognostic factors than those without biochemical failure: median pre-RT PSA 15.9 vs. 9.0 (p < 0.001), and Gleason score of 7 or greater for 48% of subjects vs. 40% (p 0.1). Relative PSA rise and slope of ln PSA vs. time were associated with cause-specific mortality (p < 0.001 and p = 0.007, respectively). Conclusion: Overall survival after conformal radiotherapy for prostate

  17. Application-Specific Graph Sampling for Frequent Subgraph Mining and Community Detection

    Energy Technology Data Exchange (ETDEWEB)

    Purohit, Sumit; Choudhury, Sutanay; Holder, Lawrence B.

    2017-12-11

    Graph mining is an important data analysis methodology, but struggles as the input graph size increases. The scalability and usability challenges posed by such large graphs make it imperative to sample the input graph and reduce its size. The critical challenge in sampling is to identify the appropriate algorithm to insure the resulting analysis does not suffer heavily from the data reduction. Predicting the expected performance degradation for a given graph and sampling algorithm is also useful. In this paper, we present different sampling approaches for graph mining applications such as Frequent Subgrpah Mining (FSM), and Community Detection (CD). We explore graph metrics such as PageRank, Triangles, and Diversity to sample a graph and conclude that for heterogeneous graphs Triangles and Diversity perform better than degree based metrics. We also present two new sampling variations for targeted graph mining applications. We present empirical results to show that knowledge of the target application, along with input graph properties can be used to select the best sampling algorithm. We also conclude that performance degradation is an abrupt, rather than gradual phenomena, as the sample size decreases. We present the empirical results to show that the performance degradation follows a logistic function.

  18. Direct Detection of Protein Biomarkers in Human Fluids Using Site-Specific Antibody Immobilization Strategies

    Directory of Open Access Journals (Sweden)

    Maria Soler

    2014-01-01

    Full Text Available Design of an optimal surface biofunctionalization still remains an important challenge for the application of biosensors in clinical practice and therapeutic follow-up. Optical biosensors offer real-time monitoring and highly sensitive label-free analysis, along with great potential to be transferred to portable devices. When applied in direct immunoassays, their analytical features depend strongly on the antibody immobilization strategy. A strategy for correct immobilization of antibodies based on the use of ProLinker™ has been evaluated and optimized in terms of sensitivity, selectivity, stability and reproducibility. Special effort has been focused on avoiding antibody manipulation, preventing nonspecific adsorption and obtaining a robust biosurface with regeneration capabilities. ProLinker™-based approach has demonstrated to fulfill those crucial requirements and, in combination with PEG-derivative compounds, has shown encouraging results for direct detection in biological fluids, such as pure urine or diluted serum. Furthermore, we have implemented the ProLinker™ strategy to a novel nanoplasmonic-based biosensor resulting in promising advantages for its application in clinical and biomedical diagnosis.

  19. A Novel Immunoreagent for the Specific and Sensitive Detection of the Explosive Triacetone Triperoxide (TATP

    Directory of Open Access Journals (Sweden)

    Michael G. Weller

    2011-07-01

    Full Text Available Triacetone triperoxide (TATP is a primary explosive, which was used in various terrorist attacks in the past. For the development of biosensors, immunochemical µ-TAS, electronic noses, immunological test kits, or test strips, the availability of antibodies of high quality is crucial. Recently, we presented the successful immunization of mice, based on the design, synthesis, and conjugation of a novel TATP derivative. Here, the long-term immunization of rabbits is shown, which resulted in antibodies of extreme selectivity and more than 1,000 times better affinity in relation to the antibodies from mice. Detection limits below 10 ng L−1 (water were achieved. The working range covers more than four decades, calculated from a precision profile. The cross-reactivity tests revealed an extraordinary selectivity of the antibodies—not a single compound could be identified as a relevant cross-reactant. The presented immunoreagent might be a major step for the development of highly sensitive and selective TATP detectors particularly for security applications.

  20. Detection of the Deformation of an Intelligent Textile in a Specific Point

    Directory of Open Access Journals (Sweden)

    José Gisbert

    2007-06-01

    Full Text Available An intelligent textile is a textile structure that measures and reacts in front of external agents or stimulus with or without integrated electronic equipment. . The finality of the present textile is to take one more step towards intelligent textile, considering the integration of electronics and textile needs, to be industrially viable and to keep up the necessary competitiveness, raising the final price as little as possible. The finality of these experiments is to develop a textile that varies in conductivity and resistance in relation to the elongation of the textile, detecting changes caused by the alteration of a piece of clothing, from the pressure of a finger on the material, for example. One of the most important characteristics of textile is the capacity of reproducing measures, of varying the response in different tests. Two lines of research were opened: the study of the most adequate structure to achieve a response that can be reproduced and the study of the best way of taking measures without altering the behavior of the textile.

  1. Probe-Specific Procedure to Estimate Sensitivity and Detection Limits for 19F Magnetic Resonance Imaging.

    Directory of Open Access Journals (Sweden)

    Alexander J Taylor

    Full Text Available Due to low fluorine background signal in vivo, 19F is a good marker to study the fate of exogenous molecules by magnetic resonance imaging (MRI using equilibrium nuclear spin polarization schemes. Since 19F MRI applications require high sensitivity, it can be important to assess experimental feasibility during the design stage already by estimating the minimum detectable fluorine concentration. Here we propose a simple method for the calibration of MRI hardware, providing sensitivity estimates for a given scanner and coil configuration. An experimental "calibration factor" to account for variations in coil configuration and hardware set-up is specified. Once it has been determined in a calibration experiment, the sensitivity of an experiment or, alternatively, the minimum number of required spins or the minimum marker concentration can be estimated without the need for a pilot experiment. The definition of this calibration factor is derived based on standard equations for the sensitivity in magnetic resonance, yet the method is not restricted by the limited validity of these equations, since additional instrument-dependent factors are implicitly included during calibration. The method is demonstrated using MR spectroscopy and imaging experiments with different 19F samples, both paramagnetically and susceptibility broadened, to approximate a range of realistic environments.

  2. Probe-Specific Procedure to Estimate Sensitivity and Detection Limits for 19F Magnetic Resonance Imaging.

    Science.gov (United States)

    Taylor, Alexander J; Granwehr, Josef; Lesbats, Clémentine; Krupa, James L; Six, Joseph S; Pavlovskaya, Galina E; Thomas, Neil R; Auer, Dorothee P; Meersmann, Thomas; Faas, Henryk M

    2016-01-01

    Due to low fluorine background signal in vivo, 19F is a good marker to study the fate of exogenous molecules by magnetic resonance imaging (MRI) using equilibrium nuclear spin polarization schemes. Since 19F MRI applications require high sensitivity, it can be important to assess experimental feasibility during the design stage already by estimating the minimum detectable fluorine concentration. Here we propose a simple method for the calibration of MRI hardware, providing sensitivity estimates for a given scanner and coil configuration. An experimental "calibration factor" to account for variations in coil configuration and hardware set-up is specified. Once it has been determined in a calibration experiment, the sensitivity of an experiment or, alternatively, the minimum number of required spins or the minimum marker concentration can be estimated without the need for a pilot experiment. The definition of this calibration factor is derived based on standard equations for the sensitivity in magnetic resonance, yet the method is not restricted by the limited validity of these equations, since additional instrument-dependent factors are implicitly included during calibration. The method is demonstrated using MR spectroscopy and imaging experiments with different 19F samples, both paramagnetically and susceptibility broadened, to approximate a range of realistic environments.

  3. Direct detection of protein biomarkers in human fluids using site-specific antibody immobilization strategies.

    Science.gov (United States)

    Soler, Maria; Estevez, M-Carmen; Alvarez, Mar; Otte, Marinus A; Sepulveda, Borja; Lechuga, Laura M

    2014-01-29

    Design of an optimal surface biofunctionalization still remains an important challenge for the application of biosensors in clinical practice and therapeutic follow-up. Optical biosensors offer real-time monitoring and highly sensitive label-free analysis, along with great potential to be transferred to portable devices. When applied in direct immunoassays, their analytical features depend strongly on the antibody immobilization strategy. A strategy for correct immobilization of antibodies based on the use of ProLinker™ has been evaluated and optimized in terms of sensitivity, selectivity, stability and reproducibility. Special effort has been focused on avoiding antibody manipulation, preventing nonspecific adsorption and obtaining a robust biosurface with regeneration capabilities. ProLinker™-based approach has demonstrated to fulfill those crucial requirements and, in combination with PEG-derivative compounds, has shown encouraging results for direct detection in biological fluids, such as pure urine or diluted serum. Furthermore, we have implemented the ProLinker™ strategy to a novel nanoplasmonic-based biosensor resulting in promising advantages for its application in clinical and biomedical diagnosis.

  4. A Novel Immunoreagent for the Specific and Sensitive Detection of the Explosive Triacetone Triperoxide (TATP).

    Science.gov (United States)

    Walter, Maria Astrid; Panne, Ulrich; Weller, Michael G

    2011-07-07

    Triacetone triperoxide (TATP) is a primary explosive, which was used in various terrorist attacks in the past. For the development of biosensors, immunochemical µ-TAS, electronic noses, immunological test kits, or test strips, the availability of antibodies of high quality is crucial. Recently, we presented the successful immunization of mice, based on the design, synthesis, and conjugation of a novel TATP derivative. Here, the long-term immunization of rabbits is shown, which resulted in antibodies of extreme selectivity and more than 1,000 times better affinity in relation to the antibodies from mice. Detection limits below 10 ng L-1 (water) were achieved. The working range covers more than four decades, calculated from a precision profile. The cross-reactivity tests revealed an extraordinary selectivity of the antibodies-not a single compound could be identified as a relevant cross-reactant. The presented immunoreagent might be a major step for the development of highly sensitive and selective TATP detectors particularly for security applications.

  5. Development of an improved species specific PCR test for detection of Haemophilus parasuis

    DEFF Research Database (Denmark)

    Angen, Øystein; Oliveira, Simone; Ahrens, Peter

    2007-01-01

    , the present PCR test was found to be 100% species specific for H. parasuis, in contrast to the PCR test of Oliveira et al., which also tested positive for strains belonging to A. indolicus, A. porcinus, and A. minor, species commonly occurring in the upper respiratory tract. However, when the PCR test...... with representatives of H. parasuis. The test was further evaluated on 55 clinical samples from 16 Danish pigs suspected for being infected with H. parasuis, showing polyserositis or septicemia at autopsy as well as on 492 nasal swabs. The test was compared with the performance of a PCR test earlier published...... by Oliveira et al. [Oliveira, S., Galina, L., Pijoan, C., 2001. Development of a PCR test to diagnose Haemophilus parasuis infections. J. Vet. Diagn. Invest. 13, 495-501]. The sensitivity of the present PCR test was found to be slightly lower when applied on clinical samples from diseased pigs and 10-fold...

  6. Impedance spectroscopy in biodynamics: Detection of specific cells (pathogens using immune coated electrodes

    Directory of Open Access Journals (Sweden)

    Eugen Gheorghiu

    2002-11-01

    Full Text Available We describe the theoretical and experimental approaches for monitoring the interfacial biomolecular reaction between immobilized antibody and the antigen binding partner (the analyte, or the targeted cell using Impedance Spectroscopy, IS. The key idea is to reveal the presence of the analyte by investigating the dynamics of the impedance changes at the interface between transducer and bulk during the process of antibody-antigen binding (coupling of specific compounds to sensor surface. In this work, antibody-antigen (Ab-Ag reaction was directly monitored using an impedance analyzer capable of ~ 1 measurement/second and covalent immobilization chemistry and modified electrodes in the absence of a redox probe. The proposed approach may be applicable to monitoring other surface interfacial reactions such as protein-protein interactions, DNA-DNA interactions, DNA-protein interactions and DNA-small molecule interactions.

  7. Improving specificity of Bordetella pertussis detection using a four target real-time PCR.

    Directory of Open Access Journals (Sweden)

    Helena Martini

    Full Text Available The incidence of whooping cough, a contagious respiratory disease caused by Bordetella pertussis, is on the rise despite existing vaccination programmes. Similar, though usually milder, respiratory symptoms may be caused by other members of the Bordetella genus: B. parapertussis, B. holmesii, and B. bronchiseptica. Pertussis diagnosis is mostly done using PCR, but the use of multiple targets is necessary in order to differentiate the different Bordetella spp. with sufficient sensitivity and specificity. In this study we evaluate a multiplex PCR assay for the differentiation of B. pertussis from other Bordetella spp., using the targets IS481, IS1001, IS1002, and recA. Moreover, we retrospectively explore the epidemiology of Bordetella spp. infections in Belgium, using the aforementioned assay over a three-year period, from 2013 until 2015.

  8. Improving specificity of Bordetella pertussis detection using a four target real-time PCR

    Science.gov (United States)

    Detemmerman, Liselot; Soetens, Oriane; Yusuf, Erlangga; Piérard, Denis

    2017-01-01

    The incidence of whooping cough, a contagious respiratory disease caused by Bordetella pertussis, is on the rise despite existing vaccination programmes. Similar, though usually milder, respiratory symptoms may be caused by other members of the Bordetella genus: B. parapertussis, B. holmesii, and B. bronchiseptica. Pertussis diagnosis is mostly done using PCR, but the use of multiple targets is necessary in order to differentiate the different Bordetella spp. with sufficient sensitivity and specificity. In this study we evaluate a multiplex PCR assay for the differentiation of B. pertussis from other Bordetella spp., using the targets IS481, IS1001, IS1002, and recA. Moreover, we retrospectively explore the epidemiology of Bordetella spp. infections in Belgium, using the aforementioned assay over a three-year period, from 2013 until 2015. PMID:28403204

  9. Optical scatterometry system for detecting specific line edge roughness of resist gratings subjected to detector noises

    International Nuclear Information System (INIS)

    Lee, Yen-Min; Li, Jia-Han; Cheng, Hsin-Hung; Wang, Fu-Min; Shen, Yu-Tian; Tsai, Kuen-Yu; Shieh, Jason J; Chen, Alek C

    2014-01-01

    The Fourier scatterometry model was used to measure the ZEP 520A electron beam resist lines with specific line edge roughness (LER). By obtaining the pupils via an objective lens, the angle-resolved diffraction spectrum was collected efficiently without additional mechanical scanning. The concavity of the pupil was considered as the weight function in specimen recognition. A series of white noises was examined in the model, and the tolerant white noise levels for different system numerical apertures (NAs) were reported. Our numerical results show that the scatterometry model of a higher NA can identify a target with a higher white noise level. Moreover, the fabricated ZEP 520A electron beam resist gratings with LER were measured by using our model, and the fitting results were matched with scanning electron microscope measurements. (paper)

  10. Sensitivity and Specificity of Double-Track Sign in the Detection of Transverse Sinus Stenosis: A Multicenter Retrospective Study.

    Science.gov (United States)

    Zhu, De-Sheng; Fu, Jue; Zhang, Yi; Xie, Chong; Wang, Xiao-Qing; Zhang, Yue; Yang, Jie; Li, Shi-Xu; Liu, Xiao-Bei; Wan, Zhi-Wen; Dong, Qiang; Guan, Yang-Tai

    2015-01-01

    Transverse sinus stenosis (TSS) is common among patients with cerebral venous sinus thrombosis. No previous studies have reported on double-track sign detected on axial Gd-enhanced T1WI in TSS. This study aimed to determine the sensitivity and specificity of the double-track sign in the detection of TSS. We retrospectively reviewed medical records of 383 patients with transverse sinus thrombosis (TST) and 30 patients with normal transverse sinus from 5 participating hospitals in china from January 2008 to June 2014. 167 feasible transverse sinuses included in this study were categorized into TSS (n = 76), transverse sinus occlusion (TSO) (n = 52) and transverse sinus normal (TSN) groups (n = 39) according to imaging diagnosis on digital subtraction angiography (DSA) or magnetic resonance venography (MRV). Double-track sign on axial Gd-enhanced T1WI was compared among the three groups. Sensitivity and specificity of double-track sign in detection of TSS were calculated, with final imaging diagnosis of TSS on DSA or MRV as the reference standard. Of 383 patients with TST recruited over a 6.5-year period, 128 patients were enrolled in the study, 255 patients were excluded because of insufficient clinical data, imaging finding and delay time, and 30 matched patients with normal transverse sinus were enrolled in the control group. Therefore, double-track sign assessment was conducted in 167 available transverse sinuses of 158 patients. Of the 76 sinuses in TSS group, 51 had double-track sign. Of the other 91 sinuses in TSO and TSN groups, 3 had a false-positive double-track sign. Thus, double-track sign on axial Gd-enhanced T1WI was 67.1% (95% CI 55.3-77.2) sensitive and 96.7% (95% CI 89.9-99.1) specific for detection of TSS. The double-track sign on axial Gd-enhanced T1WI is highly specific and moderate sensitive for detection of TSS. Nevertheless, it could be a direct sign and might provide an early clue for TSS.

  11. Direct and indirect singlet scalar dark matter detection in the lepton-specific two-Higgs-doublet model

    International Nuclear Information System (INIS)

    Boucenna, M. S.; Profumo, S.

    2011-01-01

    A recent study of gamma-ray data from the Galactic center motivates the investigation of light (∼7-10 GeV) particle dark matter models featuring tau-lepton pairs as dominant annihilation final state. The lepton-specific two-Higgs-doublet model provides a natural framework where light, singlet scalar dark matter can pair-annihilate dominantly into tau leptons. We calculate the nucleon-dark matter cross section for singlet scalar dark matter within the lepton-specific two-Higgs-doublet model framework, and compare with recent results from direct detection experiments. We study how direct dark matter searches can be used to constrain the dark matter interpretation of gamma-ray observations, for different dominant annihilation final states. We show that models exist with the correct thermal relic abundance that could fit the claimed gamma-ray excess from the Galactic center region and have direct detection cross sections of the order of what is needed to interpret recent anomalous events reported by direct detection experiments.

  12. Specific detection of Angiostrongylus cantonensis in the snail Achatina fulica using a loop-mediated isothermal amplification (LAMP) assay.

    Science.gov (United States)

    Liu, Chun-Yan; Song, Hui-Qun; Zhang, Ren-Li; Chen, Mu-Xin; Xu, Min-Jun; Ai, Lin; Chen, Xiao-Guang; Zhan, Xi-Mei; Liang, Shao-Hui; Yuan, Zi-Guo; Lin, Rui-Qing; Zhu, Xing-Quan

    2011-08-01

    Angiostrongylus cantonensis, a rat lungworm, can cause eosinophilic meningitis and angiostrongyliasis in humans following ingestion of contaminated foods or intermediate/paratenic hosts with infective larvae. The snail Achatina fulica is one of the important intermediate hosts of A. cantonensis and is commonly eaten by humans in some countries. In the present study, we developed a loop-mediated isothermal amplification (LAMP) method for the specific detection of A. cantonensis in Ac. fulica. Primers for LAMP were designed based on the first internal transcribed spacer (ITS-1) of nuclear ribosomal DNA (rDNA) of A. cantonensis. Specificity tests showed that only the products of A. cantonensis were detected when DNA samples of A. cantonensis and the heterologous control samples Anisakis simplex s.s, Trichuris trichiura, Toxocara canis, Trichinella spiralis and Ascaris lumbricoides were amplified by LAMP. Sensitivity evaluation indicated that the LAMP assay is 10 times more sensitive than the conventional polymerase chain reaction (PCR) assay. The established LAMP assay is rapid, inexpensive and easy to be performed. It can be used in clinical applications for rapid and sensitive detection of A. cantonensis in snails, which has implications for the effective control of angiostrongyliasis. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Detection of Turner syndrome using X-chromosome inactivation specific differentially methylated CpG sites: A pilot study.

    Science.gov (United States)

    Zhang, Qiang; Guo, Xiaohong; Tian, Tian; Wang, Teng; Li, Qiaoli; Wang, Lei; Liu, Yun; Xing, Qinghe; He, Lin; Zhao, Xinzhi

    2017-05-01

    Early diagnosis of Turner syndrome (TS) may improve preventive measures and treatment. X-chromosome inactivation specific differentially methylated CpG sites (XIDMSs) that are high methylated in inactive X chromosomes (Xi) and unmethylated in active X chromosomes (Xa) may be potential makers for TS detection. The candidate XIDMSs were screened from 9 male and 12 female DNA samples with normal karyotypes using the Illumina 450k array and validated by bisulfite sequencing PCR and pyrosequencing assay. X chromosome dosage was calculated according to the methylation level of multiple XIDMSs. Overall, 108 candidate XIDMSs were screened by the 450k array. Validations indicated that XIDMSs gathered and formed the X-chromosome inactivation specific differentially methylated regions (XIDMRs). Using 3 XIDMRs at SAT1, UXT and UTP14A loci, 36 TS, 22 normal female and 6 male samples were analyzed. Methylation levels of the 20 XIDMSs in the XIDMRs could distinguish between TS and normal female DNA samples, the X chromosome dosage was consistent with karyotyping data. Analyzing samples of 2 triple X syndrome and 3 Klinefelter syndrome patients suggested that this method could be used to detect X chromosome aneuploids other than TS. XIDMSs are widely spread along the X chromosome and might be effective markers for detection of TS and other X chromosome aneuploids. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Isolation and characterization of Bacteroides host strain HB-73 used to detect sewage specific phages in Hawaii.

    Science.gov (United States)

    Vijayavel, Kannappan; Fujioka, Roger; Ebdon, James; Taylor, Huw

    2010-06-01

    Previous studies have shown that Escherichia coli and enterococci are unreliable indicators of fecal contamination in Hawaii because of their ability to multiply in environmental soils. In this study, the method of detecting Bacteroides phages as specific markers of sewage contamination in Hawaii's recreational waters was evaluated because these sewage specific phages cannot multiply under environmental conditions. Bacteroides hosts (GB-124, GA-17), were recovered from sewage samples in Europe and were reported to be effective in detecting phages from sewage samples obtained in certain geographical areas. However, GB-124 and GA-17 hosts were ineffective in detecting phages from sewage samples obtained in Hawaii. Bacteroides host HB-73 was isolated from a sewage sample in Hawaii, confirmed as a Bacteroides sp. and shown to recover phages from multiple sources of sewage produced in Hawaii at high concentrations (5.2-7.3 x 10(5) PFU/100 mL). These Bacteroides phages were considered as potential markers of sewage because they also survived for three days in fresh stream water and two days in marine water. Water samples from Hawaii's coastal swimming beaches and harbors, which were known to be contaminated with discharges from streams, were shown to contain moderate (20-187 CFU/100 mL) to elevated (173-816 CFU/100 mL) concentrations of enterococci. These same samples contained undetectable levels (Hawaii and the most likely source of these enterococci is from environmental soil rather than from sewage. 2010 Elsevier Ltd. All rights reserved.

  15. A universal colorimetry for nucleic acids and aptamer-specific ligands detection based on DNA hybridization amplification.

    Science.gov (United States)

    Li, Shuang; Shang, Xinxin; Liu, Jia; Wang, Yujie; Guo, Yingshu; You, Jinmao

    2017-07-01

    We present a universal amplified-colorimetric for detecting nucleic acid targets or aptamer-specific ligand targets based on gold nanoparticle-DNA (GNP-DNA) hybridization chain reaction (HCR). The universal arrays consisted of capture probe and hairpin DNA-GNP. First, capture probe recognized target specificity and released the initiator sequence. Then dispersed hairpin DNA modified GNPs were cross-linked to form aggregates through HCR events triggered by initiator sequence. As the aggregates accumulate, a significant red-to purple color change can be easily visualized by the naked eye. We used miRNA target sequence (miRNA-203) and aptamer-specific ligand (ATP) as target molecules for this proof-of-concept experiment. Initiator sequence (DNA2) was released from the capture probe (MNP/DNA1/2 conjugates) under the strong competitiveness of miRNA-203. Hairpin DNA (H1 and H2) can be complementary with the help of initiator DNA2 to form GNP-H1/GNP-H2 aggregates. The absorption ratio (A 620 /A 520 ) values of solutions were a sensitive function of miRNA-203 concentration covering from 1.0 × 10 -11  M to 9.0 × 10 -10  M, and as low as 1.0 × 10 -11  M could be detected. At the same time, the color changed from light wine red to purple and then to light blue have occurred in the solution. For ATP, initiator sequence (5'-end of DNA3) was released from the capture probe (DNA3) under the strong combination of aptamer-ATP. The present colorimetric for specific detection of ATP exhibited good sensitivity and 1.0 × 10 -8  M ATP could be detected. The proposed strategy also showed good performances for qualitative analysis and quantitative analysis of intracellular nucleic acids and aptamer-specific ligands. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. A specific Tween-80-Rhodamine S-MWNTs phosphorescent reagent for the detection of trace calcitonin

    Energy Technology Data Exchange (ETDEWEB)

    Liu Jiaming, E-mail: zzsyliujiaming@163.com [Department of Chemistry and Environmental Science, Zhangzhou Normal College, Zhangzhou, 363000 (China); Huang Xiaomei; Zhang Lihong; Zheng Zhiyong [Department of Chemistry and Environmental Science, Zhangzhou Normal College, Zhangzhou, 363000 (China); Department of Food and Biological Engineering, Zhangzhou Institute of Technology, Zhangzhou, 363000 (China); Lin Xuan; Zhang Xiaoyang; Jiao Li; Cui Malin [Department of Chemistry and Environmental Science, Zhangzhou Normal College, Zhangzhou, 363000 (China); Jiang Shulian [Fujian Provincial Bureau of Quality and Technical Supervision, Zhangzhou, 363000 (China); Lin Shaoqin [Department of Biochemistry, Fujian Education College, Fuzhou 350001 (China)

    2012-09-26

    Graphical abstract: A new Tween-80-Rhodamine S-water-soluble multi-walled carbon nanotubes (Tween-80-Rhod.S-MWNTs-EDC-NHS, TRMEN) phosphorescent labelling reagent was developed. High sensitive solid substrate room temperature phosphorescence immunoassay (SSRTPIA) for the determination of calcitonin (CT) in human serum and the prediction of human diseases based on the TRMEN could be used to label anti-calcitonin antibody (Ab{sub CT}) to form the TRMEN-Ab{sub CT} labelling product, which could take high specific immunoreaction with CT causing that the {Delta}I{sub p} of the system was linear to the content of CT. Moreover, the reaction mechanisms of both labelling Ab{sub CT} by TRMEN and SSRTPIA for the determination of trace CT were discussed. This research not only provides a new hormones analysis method, but also expands the application field of MWNTs and promotes the development of SSRTP and IA. --Highlights: Black-Right-Pointing-Pointer A Tween-80-Rhodamine S-multi-walled carbon nanotubes labelling reagent was developed. Black-Right-Pointing-Pointer The phosphorescence immunoassay was established for the determination of calcitonin. Black-Right-Pointing-Pointer This method has been applied to determine CT and the prediction of diseases. Black-Right-Pointing-Pointer The structure of MWNTs was characterized with SEM and IR. Black-Right-Pointing-Pointer The mechanisms for both determining trace CT and labelling Ab{sub CT} were discussed. - Abstract: The present study proposed a simple sensitive and specific immunoassay for the quantification of calcitonin (CT) in human serum with water-soluble multi-walled carbon nanotubes (MWNTs). The -COOH group of MWNTs could react with the -NH- group of rhodamine S (Rhod.S) molecules to form Rhod.S-MWNTs, which could emit room temperature phosphorescence (RTP) on acetate cellulose membrane (ACM) and react with Tween-80 to form micellar compound. Tween-80-Rhod.S-MWNTs (TRM), as a phosphorescent labelling reagent, could

  17. Nanozyme-based bio-barcode assay for high sensitive and logic-controlled specific detection of multiple DNAs.

    Science.gov (United States)

    Lin, Xiaodong; Liu, Yaqing; Tao, Zhanhui; Gao, Jinting; Deng, Jiankang; Yin, Jinjin; Wang, Shuo

    2017-08-15

    Since HCV and HIV share a common transmission path, high sensitive detection of HIV and HCV gene is of significant importance to improve diagnosis accuracy and cure rate at early stage for HIV virus-infected patients. In our investigation, a novel nanozyme-based bio-barcode fluorescence amplified assay is successfully developed for simultaneous detection of HIV and HCV DNAs with excellent sensitivity in an enzyme-free and label-free condition. Here, bimetallic nanoparticles, PtAu NPs , present outstanding peroxidase-like activity and act as barcode to catalyze oxidation of nonfluorescent substrate of amplex red (AR) into fluorescent resorufin generating stable and sensitive "Turn On" fluorescent output signal, which is for the first time to be integrated with bio-barcode strategy for fluorescence detection DNA. Furthermore, the provided strategy presents excellent specificity and can distinguish single-base mismatched mutant from target DNA. What interesting is that cascaded INHIBIT-OR logic gate is integrated with biosensors for the first time to distinguish individual target DNA from each other under logic function control, which presents great application in development of rapid and intelligent detection. Copyright © 2017. Published by Elsevier B.V.

  18. Direct ex vivo detection of HLA-DR3-restricted cytomegalovirus- and Mycobacterium tuberculosis-specific CD4+ T cells.

    Science.gov (United States)

    Bronke, Corine; Palmer, Nanette M; Westerlaken, Geertje H A; Toebes, Mireille; van Schijndel, Gijs M W; Purwaha, Veenu; van Meijgaarden, Krista E; Schumacher, Ton N M; van Baarle, Debbie; Tesselaar, Kiki; Geluk, Annemieke

    2005-09-01

    In order to detect epitope-specific CD4+ T cells in mycobacterial or viral infections in the context of human class II major histocompatibility complex protein human leukocyte antigen (HLA)-DR3, two HLA-DR3 tetrameric molecules were successfully produced. One contained an immunodominant HLA-DR3-restricted T-cell epitope derived from the 65-kDa heat-shock protein of Mycobacterium tuberculosis, peptide 1-13. For the other tetramer, we used an HLA-DR3-restricted T-cell epitope derived from cytomegalovirus (CMV) pp65 lower matrix protein, peptide 510-522, which induced high levels of interferon (IFN)-gamma-producing CD4+ T cells in three of four HLA-DR3-positive CMV-seropositive individuals up to 0.84% of CD4+ T cells by intracellular cytokine staining. In peripheral blood mononuclear cells from M. tuberculosis-exposed, Mycobacterium bovis bacille Calmette-Guérin (BCG)-vaccinated, or CMV-seropositive individuals, we were able to directly detect with both tetramers epitope-specific T cells up to 0.62% and 0.45% of the CD4+ T-cell population reactive to M. tuberculosis and CMV, respectively. After a 6-day culture with peptide p510-522, the frequency of CMV-specific tetramer-binding T cells was expanded up to 9.90% tetramer+ CFSElow (5,6-carboxyfluorescein diacetate succinimidyl ester) cells within the CD4+ T-cell population, further confirming the specificity of the tetrameric molecules. Thus, HLA-DR3/peptide tetrameric molecules can be used to investigate HLA-DR3-restricted antigen-specific CD4+ T cells in clinical disease or after vaccination.

  19. Clinical Value of Specific Immunoglobulin E Detection by Enzyme-Linked Immunosorbent Assay in Cases of Acquired and Congenital Toxoplasmosis

    Science.gov (United States)

    Foudrinier, F.; Villena, I.; Jaussaud, R.; Aubert, D.; Chemla, C.; Martinot, F.; Pinon, J. M.

    2003-01-01

    The clinical value of immunoenzymatic (enzyme-linked immunosorbent assay) detection of anti-Toxoplasma immunoglobulin E (IgE) was assessed by studying 2,036 sera from 792 subjects, comprising seronegative controls and subjects with acute, active, reactivated, or congenital toxoplasmosis. Included were nonimmunized adults; pregnant women with recently acquired infection (acute toxoplasmosis); immunocompetent subjects with recently acquired severe infection (active toxoplasmosis) expressed as fever, adenopathies, splenomegaly, pneumonia, meningitis, or disseminated infection; subjects—some of them immunocompromised—whose previously moderate IgG antibody levels rose, suggesting a reactivation of quiescent toxoplasmosis; and infants born to seroconverted mothers and evaluated for diagnosis of congenital infection and therapeutic management. Specific IgE antibodies were never detected in seronegative subjects. They were present in 85.7% of asymptomatic seroconverters and in 100% of seroconverters with overt toxoplasmosis, following two different kinetics: in the former, the specific IgE titer generally presented a brief peak 2 to 3 months postinfection and then fell rapidly, whereas specific IgE persisted at a very high titer for several months in the latter. IgE emerged concomitantly with the increase in IgG during toxoplasmic reactivation. For neonatal diagnosis of congenital toxoplasmosis, IgE was less informative than IgM and IgA (sensitivities, 59.5, 64.3, and 76.2%, respectively) and had a specificity of 91.9%. Nevertheless, simultaneous measurement of the three isotypes at birth improved the diagnostic yield to 81% relative to the combination of IgA and IgM. Emergence of specific IgE during postnatal treatment for congenital toxoplasmosis is a sign of poor adherence or inadequate dosing. PMID:12682160

  20. Label-free aptamer-based sensor for specific detection of malathion residues by surface-enhanced Raman scattering

    Science.gov (United States)

    Nie, Yonghui; Teng, Yuanjie; Li, Pan; Liu, Wenhan; Shi, Qianwei; Zhang, Yuchao

    2018-02-01

    A novel label-free aptamer surface-enhanced Raman scattering (SERS) sensor for trace malathion residue detection was proposed. In this process, the binding of malathion molecule with aptamer is identified directly. The silver nanoparticles modified with positively charged spermine served as enhancing and capture reagents for the negatively charged aptamer. Then, the silver nanoparticles modified by aptamer were used to specifically capture the malathion. The SERS background spectra of spermine, aptamer, and malathion were recorded and distinguished with the spectrum of malathion-aptamer. To enhance the characteristic peak signal of malathion captured by the aptamer, the aggregate reagents (NaCl, KCl, MgCl2) were compared and selected. The selectivity of this method was verified in the mixed-pesticide standard solution, which included malathion, phosmet, chlorpyrifos-methyl, and fethion. Results show that malathion can be specifically identified when the mixed-pesticide interferences existed. The standard curve was established, presenting a good linear range of 5 × 10- 7 to 1 × 10- 5 mol·L- 1. The spiked experiments for tap water show good recoveries from 87.4% to 110.5% with a relative standard deviation of less than 4.22%. Therefore, the proposed label-free aptamer SERS sensor is convenient, specifically detects trace malathion residues, and can be applied for qualitative and quantitative analysis of other pesticides.

  1. Detection of Francisella tularensis-Specific Antibodies in Patients with Tularemia by a Novel Competitive Enzyme-Linked Immunosorbent Assay

    Science.gov (United States)

    Sharma, Neekun; Hotta, Akitoyo; Yamamoto, Yoshie; Fujita, Osamu; Uda, Akihiko; Morikawa, Shigeru; Yamada, Akio

    2013-01-01

    A novel competitive enzyme-linked immunosorbent assay (cELISA) was developed and evaluated for detection of antibodies against Francisella tularensis in humans. The assay is based on the ability of serum antibodies to inhibit the binding of monoclonal antibodies (MAbs) directed against F. tularensis lipopolysaccharide antigens. The assay was evaluated using serum samples of tularemia patients, inactivated F. tularensis-immunized rabbits, and F. tularensis-infected mice. Antibodies against F. tularensis were successfully detected in serum samples of tularemia patients as well as the immunized and infected animals. The cELISA method was compared to indirect ELISA (iELISA) and the commonly used microagglutination test (MA) using serum samples of 19 tularemia patients and 50 healthy individuals. The sensitivity and specificity of cELISA were 93.9 and 96.1%, respectively, in comparison to the iELISA. MA was less sensitive than cELISA with a sensitivity and specificity of only 81.8 and 98.0%, respectively. A high degree of correlation (R2 = 0.8226) was observed between cELISA and iELISA results. The novel cELISA developed in this study appears to be highly sensitive and specific for serodiagnosis of human tularemia. The potential of the MAb-based cELISA to be used in both human and animal samples emphasizes its usefulness for serological survey of tularemia among multiple animal species. PMID:23114700

  2. Flanking sequence determination and event-specific detection of genetically modified wheat B73-6-1.

    Science.gov (United States)

    Xu, Junyi; Cao, Jijuan; Cao, Dongmei; Zhao, Tongtong; Huang, Xin; Zhang, Piqiao; Luan, Fengxia

    2013-05-01

    In order to establish a specific identification method for genetically modified (GM) wheat, exogenous insert DNA and flanking sequence between exogenous fragment and recombinant chromosome of GM wheat B73-6-1 were successfully acquired by means of conventional polymerase chain reaction (PCR) and thermal asymmetric interlaced (TAIL)-PCR strategies. Newly acquired exogenous fragment covered the full-length sequence of transformed genes such as transformed plasmid and corresponding functional genes including marker uidA, herbicide-resistant bar, ubiquitin promoter, and high-molecular-weight gluten subunit. The flanking sequence between insert DNA revealed high similarity with Triticum turgidum A gene (GenBank: AY494981.1). A specific PCR detection method for GM wheat B73-6-1 was established on the basis of primers designed according to the flanking sequence. This specific PCR method was validated by GM wheat, GM corn, GM soybean, GM rice, and non-GM wheat. The specifically amplified target band was observed only in GM wheat B73-6-1. This method is of high specificity, high reproducibility, rapid identification, and excellent accuracy for the identification of GM wheat B73-6-1.

  3. Specific Detection of Dog Podoplanin Expressed in Renal Glomerulus by a Novel Monoclonal Antibody PMab-38 in Immunohistochemistry.

    Science.gov (United States)

    Honma, Ryusuke; Kaneko, Mika K; Ogasawara, Satoshi; Fujii, Yuki; Konnai, Satoru; Takagi, Michiaki; Kato, Yukinari

    2016-08-01

    Podoplanin (PDPN) is expressed in several normal tissues including podocytes of renal glomerulus, lymphatic endothelial cells (LECs), and type I alveolar cells of lung. PDPN activates platelet aggregation by binding to C-type lectin-like receptor-2 (CLEC-2) on platelets. Many monoclonal antibodies (mAbs) against human PDPN, mouse PDPN, rat PDPN, rabbit PDPN, and bovine PDPN have been established; antidog PDPN (dPDPN) mAbs have not been developed. Herein, we immunized mice with the recombinant proteins of dPDPN and developed anti-dPDPN mAbs. One of the clones, PMab-38, is useful for detecting podocytes in immunohistochemical analysis; in contrast, it did not react with LECs or type I alveolar cells. PMab-38 also detected dPDPN specifically in flow cytometry and Western blot analysis. PMab-38 is expected to be useful for investigating the function of dPDPN, which is expressed in podocytes.

  4. Prostate-specific membrane antigen PET/MRI validation of MR textural analysis for detection of transition zone prostate cancer.

    Science.gov (United States)

    Bates, Anthony; Miles, Kenneth

    2017-12-01

    To validate MR textural analysis (MRTA) for detection of transition zone (TZ) prostate cancer through comparison with co-registered prostate-specific membrane antigen (PSMA) PET-MR. Retrospective analysis was performed for 30 men who underwent simultaneous PSMA PET-MR imaging for staging of prostate cancer. Thirty texture features were derived from each manually contoured T2-weighted, transaxial, prostatic TZ using texture analysis software that applies a spatial band-pass filter and quantifies texture through histogram analysis. Texture features of the TZ were compared to PSMA expression on the corresponding PET images. The Benjamini-Hochberg correction controlled the false discovery rate at prostate cancer. • Prostate transition zone (TZ) MR texture analysis may assist in prostate cancer detection. • Abnormal transition zone PSMA expression correlates with altered texture on T2-weighted MR. • TZ with abnormal PSMA expression demonstrates significantly reduced MI, SD and MPP.

  5. Fluorescence biosensor based on CdTe quantum dots for specific detection of H5N1 avian influenza virus

    Science.gov (United States)

    Hoa Nguyen, Thi; Dieu Thuy Ung, Thi; Hien Vu, Thi; Tran, Thi Kim Chi; Quyen Dong, Van; Khang Dinh, Duy; Liem Nguyen, Quang

    2012-09-01

    This report highlights the fabrication of fluorescence biosensors based on CdTe quantum dots (QDs) for specific detection of H5N1 avian influenza virus. The core biosensor was composed of (i) the highly luminescent CdTe/CdS QDs, (ii) chromatophores extracted from bacteria Rhodospirillum rubrum, and (iii) the antibody of β-subunit. This core part was linked to the peripheral part of the biosensor via a biotin-streptavidin-biotin bridge and finally connected to the H5N1 antibody to make it ready for detecting H5N1 avian influenza virus. Detailed studies of each constituent were performed showing the image of QDs-labeled chromatophores under optical microscope, proper photoluminescence (PL) spectra of CdTe/CdS QDs, chromatophores and the H5N1 avian influenza viruses.

  6. Detecting non-orthology in the COGs database and other approaches grouping orthologs using genome-specific best hits.

    Science.gov (United States)

    Dessimoz, Christophe; Boeckmann, Brigitte; Roth, Alexander C J; Gonnet, Gaston H

    2006-01-01

    Correct orthology assignment is a critical prerequisite of numerous comparative genomics procedures, such as function prediction, construction of phylogenetic species trees and genome rearrangement analysis. We present an algorithm for the detection of non-orthologs that arise by mistake in current orthology classification methods based on genome-specific best hits, such as the COGs database. The algorithm works with pairwise distance estimates, rather than computationally expensive and error-prone tree-building methods. The accuracy of the algorithm is evaluated through verification of the distribution of predicted cases, case-by-case phylogenetic analysis and comparisons with predictions from other projects using independent methods. Our results show that a very significant fraction of the COG groups include non-orthologs: using conservative parameters, the algorithm detects non-orthology in a third of all COG groups. Consequently, sequence analysis sensitive to correct orthology assignments will greatly benefit from these findings.

  7. 99mTc-UBI Biokinetics: A Specific Peptide for Infection Detection

    Science.gov (United States)

    Rodríguez-Cortés, J.; Meléndez-Alafort, L.; Herrera-Rodríguez, R.; Ferro-Flores, G.; Mitsoura, E.; Martínez-Duncker, C.

    2003-09-01

    Recently, antimicrobial peptides have been proposed as new agents to distinguish between bacterial infections and sterile inflammatory processes. Based on these considerations, Ubiquicidin peptide 29-41 (UBI) has been labeled with 99mTc using a new direct method showing a radiochemical purity > 97 %, high stability in human serum, and low protein binding. In addition 99mTc-UBI showed a specific in vitro and in vivo binding to bacteria. However its biokinetic parameters have not been evaluated since it is one of the new generation radiopharmaceuticals based on peptide structures. Therefore the aim of this project was to establish the biokinetic model for 99mTc-UBI. An activity from 74 to 148 MBq was injected to patients with bone infection and 5 whole body scans were taken at 1, 30, 120, 240 min and 24 h after radiopharmaceutical administration, with a dual head scanner. Urine was collected for 24 h. An antropomorphic phantom was previously used to calculate the effect of attenuation and scattered radiation on the gamma camera acquisition images. ROIs of the selected organs in patients (kidney, liver, heart, bone, soft tissue and lesion) were drawn, and attenuation and scatter corrected. The % urine elimination at 24 h and time integrated ROIs (cpm/pixel/ROIs) were used to obtain the residence time (τ) in each tissue and to establish the biokinetic model. Pharmacokinetic data show that blood clearance is biexponential with a mean residence time in the central compartment of 0.52 h. The images showed non-accumulation in metabolic organs. More than 75 % of the injected activity was eliminated by renal clearance 4 h after 99mTc-UBI administration. The mean radiation dose calculated according to the MIRD formalism was 0.130 mGy/MBq for kidney and the effective dose was 4.29 × 10-3 mSv/MBq.

  8. [Specific detection of urinary sympathomimetic amines for control of anti-doping by gas chromatography-mass spectroscopy].

    Science.gov (United States)

    Franceschini, A; Duthel, J M; Vallon, J J

    1991-03-22

    A specific, sensitive and reliable gas chromatography-mass spectrometry (GC-MS) technique for detection of sympathomimetic amines following urinary extraction is proposed. Amphetamine, phentermine, ephedrine, mephenorex, methylphenidate, benzphetamine, clobenzorex and internal standard (fenfluramine) are extracted from urines at pH 7.0 using elution by chloroform-isopropanol on C18 cartridges. Derivatization followed by GC-MS analysis allows identification of these drugs founded on relative retention times and mass spectra. The quantitation limit for derivatizable drugs was found to be 200 ng/ml and 500 ng/ml for underivatizable drugs.

  9. Development of a multiplex assay for genus- and species-specific detection of Phytophthora based on differences in mitochondrial gene order

    Science.gov (United States)

    G. J. Bilodeau; F. N. Martin; M. D. Coffey; C. L. Blomquist

    2014-01-01

    A molecular diagnostic assay for Phytophthora spp. that is specific, sensitive, has both genus- and species-specific detection capabilities multiplexed, and can be used to systematically develop markers for detection of a wide range of species would facilitate research and regulatory efforts. To address this need, a marker system was developed...

  10. Micro solid-phase radioimmunoassay for detection of herpesvirus type-specific antibody: parameters involved in standardization

    Energy Technology Data Exchange (ETDEWEB)

    Matson, D.O.; Adler-Storthz, K.; Adam, E.; Dreesman, G.R. (Baylor Univ., Houston, TX (USA). Coll. of Medicine)

    1983-02-01

    A micro solid-phase radioimmunoassay (micro-SPRIA) was developed to demonstrate type-specific antibodies to herpes simplex virus types 1 and 2 (HSV1 and HSV2). Glycoproteins from the 123,000 dalton region of HSV1 (VP123) and the 119,000 dalton region of HSV2 (VP119) were isolated on preparative polyacrylamide gels for use as antigens in the micro-SPRIA. Human sera selected from clinical samples by virological history and appropriate microneutralization data were used to standardize the micro-SPRIA. Optimization of the assay required the use of siliconized microtiter wells for adsorption of antigen. Maximized results were highly dependent on the concentrations of antigen, primary antibody, and secondary antibody as well as the diluents used for these principal test reagents. Incorporation of HSV glycoproteins of each respective type with the optimal condition established in this study facilitates the direct detection of type-specific antibody in human sera.

  11. [Branch-specific detection of phenols and assessment of ground water solubility].

    Science.gov (United States)

    Fischer, F; Kerndorff, H; Kühn, S

    2000-01-01

    There are about 500 technically relevant phenolic compounds such as cresols, chlorophenols or nitrophenols. It is most preferable to determine phenols as single compounds via gas chromatography. Further, phenols can also be assayed as photometrically as an overall parameter (Phenolindex): however, no conclusions about specific compounds can be drawn from this type of test. Also this method is not as reliable for an hazard assessment as gas chromatography. First, not all phenols, for instance resorcinol or 1-naphthol can be determined with this method. Second, phenolic groups in humic substances, which do not constitute a threat for groundwater, are determined alongside environmentally relevant phenols using this method. In most cases, it is possible to deduce which phenols can be expected in the groundwater of contaminated sites from the type of industrial usage, such as chlorophenols and pulp bleaching or nitrophenols and the production of explosives. Phenols are formed during coal combustion for instance at cokemanufactures or gasworks. They are important raw materials for the chemical industry from which resins, surfactants, pharmaceuticals, pigments, explosives, and stabilizers are produced. During the 80's phenol, cresols, nonylphenols, anisidines, aminophenols, dihydroxybenzenes, and naphthols were manufactured in amounts exceeding 10,000 t/a. Also, phenolic compounds are used as additives in many areas for example as solvents in the electric industry, in sawmills, papermanufacture, electroplating of metal sheets, as photographic developers, as textile dyes, or for the tanning of hydes. Due to the formation and use of phenols at industrial sites, groundwater contaminations are possible via infiltration through the unsaturated zone. Especially at gasworks and ammunition factories, groundwater contaminations with phenols have become known. In the vicinity of railway tracks and associated facillities contaminations due to the use of pesticides or mineral oils

  12. Development of a Sensitive and Specific Serological Assay Based on Luminex Technology for Detection of Antibodies to Zaire Ebola Virus.

    Science.gov (United States)

    Ayouba, Ahidjo; Touré, Abdoulaye; Butel, Christelle; Keita, Alpha Kabinet; Binetruy, Florian; Sow, Mamadou S; Foulongne, Vincent; Delaporte, Eric; Peeters, Martine

    2017-01-01

    The recent Zaire Ebola virus (EBOV) outbreak in West Africa illustrates clearly the need for additional studies with humans and animals to elucidate the ecology of Ebola viruses (EBVs). In this study, we developed a serological assay based on the Luminex technology. Nine recombinant proteins representing different viral regions (nucleoprotein [NP], 40-kDa viral protein [VP40], and glycoprotein [GP]) from four of the five EBV lineages were used. Samples from 94 survivors of the EBOV outbreak in Guinea and negative samples from 108 patients in France were used to calculate test performance for EBOV detection and cross-reaction with other Ebola virus lineages. For EBOV antibody detection, sensitivities of 95.7%, 96.8%, and 92.5% and specificities of 94.4%, 95.4%, and 96.3% for NP, GP, and VP40, respectively, were observed. All EBOV-negative samples that presented a reaction, except for one, interacted with a single antigen, whereas almost all samples from EBOV survivors were simultaneously reactive with NP and GP (90/94) or with NP, GP, and VP40 (87/94). Considering as positive for past EBOV infection only samples that reacted with EBOV NP and GP, sensitivity was 95.7% and specificity increased to 99.1%. Comparing results with commercial EBOV NP and GP enzyme-linked immunosorbent assays (ELISAs; Alpha Diagnostic, San Antonio, TX), lower sensitivity (92.5%) and high specificity (100%) were observed with the same positivity criteria. Samples from EBOV survivors cross-reacted with GP from Sudan Ebola virus (GP-SUDV) (81.9%), GP from Bundibugyo Ebola virus (GP-BDBV) (51.1%), GP from Reston Ebola virus (GP-RESTV) (9.6%), VP40-SUDV (76.6%), and VP40-BDBV (38.3%). Overall, we developed a sensitive and specific high-throughput serological assay, and defined an algorithm, for epidemiological surveys with humans. Copyright © 2016 American Society for Microbiology.

  13. Species-specific markers for the differential diagnosis of Trypanosoma cruzi and Trypanosoma rangeli and polymorphisms detection in Trypanosoma rangeli.

    Science.gov (United States)

    Ferreira, Keila Adriana Magalhães; Fajardo, Emanuella Francisco; Baptista, Rodrigo P; Macedo, Andrea Mara; Lages-Silva, Eliane; Ramírez, Luis Eduardo; Pedrosa, André Luiz

    2014-06-01

    Trypanosoma cruzi and Trypanosoma rangeli are kinetoplastid parasites which are able to infect humans in Central and South America. Misdiagnosis between these trypanosomes can be avoided by targeting barcoding sequences or genes of each organism. This work aims to analyze the feasibility of using species-specific markers for identification of intraspecific polymorphisms and as target for diagnostic methods by PCR. Accordingly, primers which are able to specifically detect T. cruzi or T. rangeli genomic DNA were characterized. The use of intergenic regions, generally divergent in the trypanosomatids, and the serine carboxypeptidase gene were successful. Using T. rangeli genomic sequences for the identification of group-specific polymorphisms and a polymorphic AT(n) dinucleotide repeat permitted the classification of the strains into two groups, which are entirely coincident with T. rangeli main lineages, KP1 (+) and KP1 (-), previously determined by kinetoplast DNA (kDNA) characterization. The sequences analyzed totalize 622 bp (382 bp represent a hypothetical protein sequence, and 240 bp represent an anonymous sequence), and of these, 581 (93.3%) are conserved sites and 41 bp (6.7%) are polymorphic, with 9 transitions (21.9%), 2 transversions (4.9%), and 30 (73.2%) insertion/deletion events. Taken together, the species-specific markers analyzed may be useful for the development of new strategies for the accurate diagnosis of infections. Furthermore, the identification of T. rangeli polymorphisms has a direct impact in the understanding of the population structure of this parasite.

  14. Event-specific qualitative and quantitative detection of five genetically modified rice events using a single standard reference molecule.

    Science.gov (United States)

    Kim, Jae-Hwan; Park, Saet-Byul; Roh, Hyo-Jeong; Shin, Min-Ki; Moon, Gui-Im; Hong, Jin-Hwan; Kim, Hae-Yeong

    2017-07-01

    One novel standard reference plasmid, namely pUC-RICE5, was constructed as a positive control and calibrator for event-specific qualitative and quantitative detection of genetically modified (GM) rice (Bt63, Kemingdao1, Kefeng6, Kefeng8, and LLRice62). pUC-RICE5 contained fragments of a rice-specific endogenous reference gene (sucrose phosphate synthase) as well as the five GM rice events. An existing qualitative PCR assay approach was modified using pUC-RICE5 to create a quantitative method with limits of detection correlating to approximately 1-10 copies of rice haploid genomes. In this quantitative PCR assay, the square regression coefficients ranged from 0.993 to 1.000. The standard deviation and relative standard deviation values for repeatability ranged from 0.02 to 0.22 and 0.10% to 0.67%, respectively. The Ministry of Food and Drug Safety (Korea) validated the method and the results suggest it could be used routinely to identify five GM rice events. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Detection of all Chlamydophila and Chlamydia spp. of veterinary interest using species-specific real-time PCR assays.

    Science.gov (United States)

    Pantchev, Alexandra; Sting, Reinhard; Bauerfeind, Rolf; Tyczka, Judith; Sachse, Konrad

    2010-12-01

    The aim of the present study was to analyse the occurrence of chlamydiae in several mammalian host species. Clinical samples that previously tested positive in a Chlamydiaceae-specific real-time PCR were retested using six species-specific real-time PCR assays to identify the chlamydial species involved. Chlamydophila (Cp.) abortus was the agent most frequently found in cattle, sheep, horses, goats, and pigs. Detection in cattle of Cp. psittaci (11% of samples) and Chlamydia (C.) suis (9%), as well as Cp. psittaci in a goat sample was somewhat unexpected. DNA of two different chlamydiae was identified in 56 (12.7%) of 440 samples tested. Cp. felis was the predominant species found in cats, while in guinea pigs and rabbits only Cp. caviae was detected. Interestingly, the latter two pathogens were also identified in samples from dogs. The data show that mixed chlamydial infections are not rare and suggest an extended host range of individual species. Copyright © 2009 Elsevier Ltd. All rights reserved.

  16. Development and validation of a real-time PCR assay for specific and sensitive detection of canid herpesvirus 1.

    Science.gov (United States)

    Decaro, Nicola; Amorisco, Francesca; Desario, Costantina; Lorusso, Eleonora; Camero, Michele; Bellacicco, Anna Lucia; Sciarretta, Rossana; Lucente, Maria Stella; Martella, Vito; Buonavoglia, Canio

    2010-10-01

    A TaqMan-based real-time PCR assay targeting the glycoprotein B-encoding gene was developed for diagnosis of canid herpesvirus 1 (CHV-1) infection. The established assay was highly specific, since no cross-reactions were observed with other canine DNA viruses, including canine parvovirus type 2, canine minute virus, or canine adenovirus types 1 and 2. The detection limit was 10(1) and 1.20 x 10(1) DNA copies per 10 microl(-1) of template for standard DNA and a CHV-1-positive kidney sample, respectively: about 1-log higher than a gel-based PCR assay targeting the thymidine kinase gene. The assay was also reproducible, as shown by satisfactory low intra-assay and inter-assay coefficients of variation. CHV-1 isolates of different geographical origins were recognised by the TaqMan assay. Tissues and clinical samples collected from three pups which died of CHV-1 neonatal infection were also tested, displaying a wide distribution of CHV-l DNA in their organs. Unlike other CHV-1-specific diagnostic methods, this quantitative assay permits simultaneous detection and quantitation of CHV-1 DNA in a wide range of canine tissues and body fluids, thus providing a useful tool for confirmation of a clinical diagnosis, for the study of viral pathogenesis and for evaluation of the efficacy of vaccines and antiviral drugs. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  17. Detection of EGFR mutations with mutation-specific antibodies in stage IV non-small-cell lung cancer

    Directory of Open Access Journals (Sweden)

    Viteri Santiago

    2010-12-01

    Full Text Available Abstract Background Immunohistochemistry (IHC with mutation-specific antibodies may be an ancillary method of detecting EGFR mutations in lung cancer patients. Methods EGFR mutation status was analyzed by DNA assays, and compared with IHC results in five non-small-cell lung cancer (NSCLC cell lines and tumor samples from 78 stage IV NSCLC patients. Results IHC correctly identified del 19 in the H1650 and PC9 cell lines, L858R in H1975, and wild-type EGFR in H460 and A549, as well as wild-type EGFR in tumor samples from 22 patients. IHC with the mAb against EGFR with del 19 was highly positive for the protein in all 17 patients with a 15-bp (ELREA deletion in exon 19, whereas in patients with other deletions, IHC was weakly positive in 3 cases and negative in 9 cases. IHC with the mAb against the L858R mutation showed high positivity for the protein in 25/27 (93% patients with exon 21 EGFR mutations (all with L858R but did not identify the L861Q mutation in the remaining two patients. Conclusions IHC with mutation-specific mAbs against EGFR is a promising method for detecting EGFR mutations in NSCLC patients. However these mAbs should be validated with additional studies to clarify their possible role in routine clinical practice for screening EGFR mutations in NSCLC patients.

  18. Aptamer-fluorescent silica nanoparticles bioconjugates based dual-color flow cytometry for specific detection of Staphylococcus aureus.

    Science.gov (United States)

    He, Xiaoxiao; Li, Yuhong; He, Dinggen; Wang, Kemin; Shangguan, Jingfang; Shi, Hui

    2014-07-01

    This paper describes a sensitive and specific determination strategy for Staphylococcus aureus (S. aureus) detection using aptamer recognition and fluorescent silica nanoparticles (FSiNPs) label based dual-color flow cytometry assay (Aptamer/FSiNPs-DCFCM). In the protocol, an aptamer, having high affinity to S. aureus, was first covalently immobilized onto chloropropyl functionalized FSiNPs through a click chemistry approach to generate aptamer-nanoparticles bioconjugates (Aptamer/FSiNPs). Next, S. aureus was incubated with Aptamer/FSiNPs, and then stained with SYBR Green I (a special staining material for the duplex DNA). Upon target binding and nucleic acid staining with SYBR Green I, the S. aureus was determined using two-color flow cytometry. The method took advantage of the specificity of aptamer, signal amplification of FSiNPs label and decreased false positives of two-color flow cytometry assay. It was demonstrated that these Aptamer/FSiNPs could efficiently recognize and fluorescently label target S. aureus. Through multiparameter determination with flow cytometry, this assay allowed for detection of as low as 1.5 x 10(2) and 7.6 x 10(2) cells mL(-1) S. aureus in buffer and spiked milk, respectively, with higher sensitivity than the Aptamer/FITC based flow cytometry.

  19. Use of Digital Rectal Examination as an Adjunct to Prostate Specific Antigen in the Detection of Clinically Significant Prostate Cancer.

    Science.gov (United States)

    Halpern, Joshua A; Oromendia, Clara; Shoag, Jonathan E; Mittal, Sameer; Cosiano, Michael F; Ballman, Karla V; Vickers, Andrew J; Hu, Jim C

    2018-04-01

    Guidelines from the NCCN ® (National Comprehensive Cancer Network®) advocate digital rectal examination screening only in men with elevated prostate specific antigen. We investigated the effect of prostate specific antigen on the association of digital rectal examination and clinically significant prostate cancer in a large American cohort. We evaluated the records of the 35,350 men who underwent digital rectal examination in the screening arm of the Prostate, Lung, Colorectal and Ovarian Cancer Screening trial for the development of clinically significant prostate cancer (Gleason 7 or greater). Followup was 343,273 person-years. The primary outcome was the rate of clinically significant prostate cancer among men with vs without suspicious digital rectal examination. We performed competing risks regression to evaluate the interaction between time varying suspicious digital rectal examination and prostate specific antigen. A total of 1,713 clinically significant prostate cancers were detected with a 10-year cumulative incidence of 5.9% (95% CI 5.6-6.2). Higher risk was seen for suspicious vs nonsuspicious digital rectal examination. Increases in absolute risk were small and clinically irrelevant for normal (less than 2 ng/ml) prostate specific antigen (1.5% vs 0.7% risk of clinically significant prostate cancer at 10 years), clinically relevant for elevated (3 ng/ml or greater) prostate specific antigen (23.0% vs 13.7%) and modestly clinically relevant for equivocal (2 to 3 ng/ml) prostate specific antigen (6.5% vs 3.5%). Digital rectal examination demonstrated prognostic usefulness when prostate specific antigen was greater than 3 ng/ml, limited usefulness for less than 2 ng/ml and marginal usefulness for 2 to 3 ng/ml. These findings support the restriction of digital rectal examination to men with higher prostate specific antigen as a reflex test to improve specificity. It should not be used as a primary screening modality to improve sensitivity. Copyright

  20. An ultrasensitive electrochemical immunosensor for the detection of prostate-specific antigen based on conductivity nanocomposite with halloysite nanotubes.

    Science.gov (United States)

    Li, Yueyuan; Khan, Malik Saddam; Tian, Lihui; Liu, Li; Hu, Lihua; Fan, Dawei; Cao, Wei; Wei, Qin

    2017-05-01

    A sensitive label-free amperometric electrochemical immunosensor for detection of prostate-specific antigen (PSA) was proposed in this work. The nanocomposite of halloysite nanotubes with polypyrrole shell and palladium nanoparticles (HNTs@PPy-Pd) was used as a novel signal label. The HNTs with adequate hydroxyl groups are economically available raw materials. PPy, as an electrically conducting polymer material, can be absorbed to the surface of HNTs by in situ oxidative polymerization of the pyrrole monomer and form a shell on the HNTs. The shell of PPy could not only improve the conductivity of the nanocomposite but also absorb large amounts of Pd nanoparticles (NPs). The Pd NPs with high electrocatalytic activity toward the reduction of H 2 O 2 and the HNTs@PPy-Pd nanocomposite as the analytical signal label could improve the sensitivity of the immunosensor. Under optimal conditions, the immunosensor showed a low detection limit (0.03 pg/mL) and a wide linear range (0.0001 to 25 ng/mL) of PSA. Moreover, its merits such as good selectivity, acceptable reproducibility, and stability indicate that the fabricated immunosensor has a promising application potential in clinical diagnosis. Graphical Abstract A new label-free amperometric electrochemical immunosensor based on HNTs@PPy-Pd nanocomposite for quantitative detection of PSA.

  1. A silicon-based electrochemical sensor for highly sensitive, specific, label-free and real-time DNA detection

    International Nuclear Information System (INIS)

    Guo, Yuanyuan; Su, Shao; Wei, Xinpan; Zhong, Yiling; Su, Yuanyuan; He, Yao; Huang, Qing; Fan, Chunhai

    2013-01-01

    We herein present a new kind of silicon-based electrochemical sensor using a gold nanoparticles-decorated silicon wafer (AuNPs@Si) as a high-performance electrode, which is facilely prepared via in situ AuNPs growth on a silicon wafer. Particularly significantly, the resultant electrochemical sensor is efficacious for label-free DNA detection with high sensitivity due to the unique merits of the prepared silicon-based electrode. Typically, DNA at remarkably low concentrations (1–10 fM) could be readily detected without requiring additional signal-amplification procedures, which is better than or comparable to the lowest DNA concentration ever detected via well-studied signal-amplification-assisted electrochemical sensors. Moreover, the silicon-based sensor features high specificity, allowing unambiguous discrimination of single-based mismatches. We further show that real-time DNA assembly is readily monitored via recording the intensity changes of current signals due to the robust thermal stability of the silicon-based electrode. The unprecedented advantages of the silicon-based electrochemical sensor would offer new opportunities for myriad sensing applications. (paper)

  2. Detecting Rice stripe virus (RSV) in the small brown planthopper (Laodelphax striatellus) with high specificity by RT-PCR.

    Science.gov (United States)

    Lijun, Cai; Xizhi, Ma; Lin, Kang; Kejing, Deng; Shouyuan, Zhao; Changben, Li

    2003-09-01

    Rice stripe disease, caused by Rice stripe virus (RSV), may lead to severe or even crippling losses in many rice-cultured countries and regions. As the most important vector of RSV, the small brown planthopper (SBPH) (Laodelphax striatellus) is largely responsible for the epidemic phase of the disease. Therefore, a rapid identification of RSV in the SBPH is of a great need for disease forecasting. A reverse transcription polymerase chain reaction (RT-PCR) assay is described to amplify a RSV gene in individual L. striatellus. By using primers matched to the viral RNA dependent RNA polymerase gene in RNA1, a 445 bp product was detected in viruliferous SBPHs. Meanwhile, the PCR products produced by the SBPH actin primers constructed across the boundary of an intron and an exon were used as RNA specific positive control for each stage of the experiment to ensure the validity of the negative results. Duplex RT-PCR conditions were established for the simultaneous detection of RSV and actin. This approach can be used for the early detection of RSV in L. striatellus and the subsequent rice stripe disease forecasting.

  3. Paraneoplastic antigen Ma2 autoantibodies as specific blood biomarkers for detection of early recurrence of small intestine neuroendocrine tumors.

    Science.gov (United States)

    Cui, Tao; Hurtig, Monica; Elgue, Graciela; Li, Su-Chen; Veronesi, Giulia; Essaghir, Ahmed; Demoulin, Jean-Baptiste; Pelosi, Giuseppe; Alimohammadi, Mohammad; Öberg, Kjell; Giandomenico, Valeria

    2010-12-30

    Small intestine neuroendocrine tumors (SI-NETs) belong to a rare group of cancers. Most patients have developed metastatic disease at the time of diagnosis, for which there is currently no cure. The delay in diagnosis is a major issue in the clinical management of the patients and new markers are urgently needed. We have previously identified paraneoplastic antigen Ma2 (PNMA2) as a novel SI-NET tissue biomarker. Therefore, we evaluated whether Ma2 autoantibodies detection in the blood stream is useful for the clinical diagnosis and recurrence of SI-NETs. A novel indirect ELISA was set up to detect Ma2 autoantibodies in blood samples of patients with SI-NET at different stages of disease. The analysis was extended to include typical and atypical lung carcinoids (TLC and ALC), to evaluate whether Ma2 autoantibodies in the blood stream become a general biomarker for NETs. In total, 124 blood samples of SI-NET patients at different stages of disease were included in the study. The novel Ma2 autoantibody ELISA showed high sensitivity, specificity and accuracy with ROC curve analysis underlying an area between 0.734 and 0.816. Ma2 autoantibodies in the blood from SI-NET patients were verified by western blot and sequential immunoprecipitation. Serum antibodies of patients stain Ma2 in the tumor tissue and neurons. We observed that SI-NET patients expressing Ma2 autoantibody levels below the cutoff had a longer progression and recurrence-free survival compared to those with higher titer. We also detected higher levels of Ma2 autoantibodies in blood samples from TLC and ALC patients than from healthy controls, as previously shown in small cell lung carcinoma samples. Here we show that high Ma2 autoantibody titer in the blood of SI-NET patients is a sensitive and specific biomarker, superior to chromogranin A (CgA) for the risk of recurrence after radical operation of these tumors.

  4. Optimization of interferon gamma ELISPOT assay to detect human cytomegalovirus specific T-cell responses in solid organ transplants.

    Science.gov (United States)

    Abate, Davide; Saldan, Alda; Forner, Gabriella; Tinto, Daniel; Bianchin, Alice; Palù, Giorgio

    2014-02-01

    Assessing the CMV specific CMI in transplant subjects represents a promising strategy to determine the risk of infection on individual basis. In this study 61 adult CMV IgG seropositive solid organ transplant recipients were examined in order to improve the efficacy of CMI detection. For this purpose, pair-wise comparisons were conducted comparing positive control stimuli PWM and PMA/iono and CMV stimuli, pp65 peptide pool and whole CMV particle. Rosette pre-depletion of blood was also investigated for detecting CD4+ or CD8+ T-cell responses using the IFN-g ELISPOT assay. In the time-points 30-180 days after transplantation, PMA/iono produced statistically significant higher responses compared to PWM, probably because PMA/iono activation pathway is independent from the effect of immunosuppressive drugs. The data showed that 11% of transplant patients displayed very low or undetectable responses to pp65 peptide pool antigen while having sustained high responses to whole CMV particle. In addition, in all the subjects analyzed, CMI responses to CMV particle produced a statistically significant higher number of spots compared to pp65 peptide pool antigen. Rosette pre-depletion of whole blood proved to be effective in detecting CD4+ or CD8+ T-cell responses similarly to flow cytometry. Taken together, the following recommendations are suggested to optimize the CMV-ELISPOT for transplantation settings: (1) use PMA/iono as positive control; (2) whole virus particle should be used to avoid peptide-related false negative responses; (3) a rosette pre-depletion step may be useful to detect CD4+ or CD8+ T-cell responses. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Comparison of dot-ELISA and standard ELISA for detection of Neisseria meningitidis outer membrane complex-specific antibodies

    Directory of Open Access Journals (Sweden)

    Elza FT Belo

    Full Text Available Dot-ELISA using the outer membrane complex antigens of Neisseria meningitidis as a target was standardized for rapid detection of meningococcal-specific antibodies in human serum. We investigated the level of meningococcal-specific IgG, IgA, and IgM in serum using dot-ELISA with outer membrane antigens prepared from Neisseria meningitidis serotype B:4.19:P1.15,3,7,9 (a strain isolated from a Brazilian epidemic. The dot-ELISA is based on the same principles as the standard ELISA and is useful for detection of anti-N. meningitidis B antibodies in serum of patients with meningococcal infections. For the assay, outer membrane complexes (OMCs were absorbed by nitrocellulose membrane and blocked with a 5% skim milk solution. Serum samples were drawn upon hospital admission and during convalescence from patients with meningococcal septicemia, and single samples were drawn from uninfected controls. We retrospectively examined a total of 57 serum samples: 35 from patients infected with N. meningitidis B, 12 from patients infected with Haemophilus influenzae b, and 10 from health individuals. When performed at room temperature, dot-ELISA took approximately four hours to perform, and the optimum antigen concentration was 0.42 µg per dot. The specificity of IgG, IgM, and IgA demonstrates that dot-ELISA using OMCs from N. meningitidis B as a target is suitable for serologic verification of clinically suspected meningococcal disease in patients and for titer determination of antibodies produced during different phases of natural infection. Furthermore, the sensitivity of dot-ELISA was comparable to that of standard ELISA. Overall, dot-ELISA is simple to perform, rapid, and low cost. Further validation of the test as a screening tool is required.

  6. Specific detection of peste des petits ruminants virus antibodies in sheep and goat sera by the luciferase

    International Nuclear Information System (INIS)

    Berguido, F.J.; Bodjo, S.C.; Loitsch, A.; Diallo, A.

    2016-01-01

    Full text: Peste des petits ruminants (PPR) is a contagious and often fatal transboundary animal disease affecting mostly sheep, goats and wild small ruminants. This disease is endemic in most of Africa, the Middle, Near East, and large parts of Asia. The casual agent is peste des petits ruminants virus (PPRV), which belongs to the genus Morbilivirus in the family Paramyxoviridae. This genus also includes measles virus (MV), canine distemper virus (CDV) and rinderpest virus (RPV). All are closely related viruses with serological cross reactivity. In this study, we have developed a Luciferase Immunoprecipitation System (LIPS) for the rapid detection of antibodies against PPRV in serum samples and for specific differentiation from antibodies against RPV. PPR and rinderpest (RP) serum samples were assayed by PPR-LIPS and two commercially available PPR cELISA tests. The PPR-LIPS showed high sensitivity and specificity for the samples tested and showed no cross reactivity with RPV unlike the commercial PPR cELISA tests which did not cross react with RPV. Based on the results shown in this study, PPR-LIPS is presented as a good candidate for the specific serosurveillance of PPR. (author)

  7. Specific absorption spectra of hemoglobin at different PO2 levels: potential noninvasive method to detect PO2 in tissues.

    Science.gov (United States)

    Liu, Peipei; Zhu, Zhirong; Zeng, Changchun; Nie, Guang

    2012-12-01

    Hemoglobin (Hb), as one of main components of blood, has a unique quaternary structure. Its release of oxygen is controlled by oxygen partial pressure (PO2). We investigate the specific spectroscopic changes in Hb under different PO2 levels to optimize clinical methods of measuring tissue PO2. The transmissivity of Hb under different PO2 levels is measured with a UV/Vis fiber optic spectrometer. Its plotted absorption spectral curve shows two high absorption peaks at 540 and 576 nm and an absorption valley at 560 nm when PO2 is higher than 100 mm Hg. The two high absorption peaks decrease gradually with a decrease in PO2, whereas the absorption valley at 560 nm increases. When PO2 decreases to approximately 0 mm Hg, the two high absorption peaks disappear completely, while the absorption valley has a hypochromic shift (8 to 10 nm) and forms a specific high absorption peak at approximately 550 nm. The same phenomena can be observed in visible reflectance spectra of finger-tip microcirculation. Specific changes in extinction coefficient and absorption spectra of Hb occur along with variations in PO2, which could be used to explain pathological changes caused by tissue hypoxia and for early detection of oxygen deficiency diseases in clinical monitoring.

  8. Detection of prostate-specific antigen with biomolecule-gated AlGaN/GaN high electron mobility transistors

    Science.gov (United States)

    Li, Jia-dong; Cheng, Jun-jie; Miao, Bin; Wei, Xiao-wei; Xie, Jie; Zhang, Jin-cheng; Zhang, Zhi-qiang; Wu, Dong-min

    2014-07-01

    In order to improve the sensitivity of AlGaN/GaN high electron mobility transistor (HEMT) biosensors, a simple biomolecule-gated AlGaN/GaN HEMT structure was designed and successfully fabricated for prostate specific antigen (PSA) detection. UV/ozone was used to oxidize the GaN surface and then a 3-aminopropyl trimethoxysilane (APTES) self-assembled monolayer was bound to the sensing region. This monolayer serves as a binding layer for attachment of the prostate specific antibody (anti-PSA). The biomolecule-gated AlGaN/GaN HEMT sensor shows a rapid and sensitive response when the target prostate-specific antigen in buffer solution was added to the antibody-immobilized sensing area. The current change showed a logarithm relationship against the PSA concentration from 0.1 pg/ml to 0.993 ng/ml. The sensitivity of 0.215% is determined for 0.1 pg/ml PSA solution. The above experimental result of the biomolecule-gated AlGaN/GaN HEMT biosensor suggested that this biosensor might be a useful tool for prostate cancer screening.

  9. Detection of prostate-specific antigen with biomolecule-gated AlGaN/GaN high electron mobility transistors

    International Nuclear Information System (INIS)

    Li, Jia-dong; Miao, Bin; Wei, Xiao-wei; Xie, Jie; Wu, Dong-min; Cheng, Jun-jie; Zhang, Jin-cheng; Zhang, Zhi-qiang

    2014-01-01

    In order to improve the sensitivity of AlGaN/GaN high electron mobility transistor (HEMT) biosensors, a simple biomolecule-gated AlGaN/GaN HEMT structure was designed and successfully fabricated for prostate specific antigen (PSA) detection. UV/ozone was used to oxidize the GaN surface and then a 3-aminopropyl trimethoxysilane (APTES) self-assembled monolayer was bound to the sensing region. This monolayer serves as a binding layer for attachment of the prostate specific antibody (anti-PSA). The biomolecule-gated AlGaN/GaN HEMT sensor shows a rapid and sensitive response when the target prostate-specific antigen in buffer solution was added to the antibody-immobilized sensing area. The current change showed a logarithm relationship against the PSA concentration from 0.1 pg/ml to 0.993 ng/ml. The sensitivity of 0.215% is determined for 0.1 pg/ml PSA solution. The above experimental result of the biomolecule-gated AlGaN/GaN HEMT biosensor suggested that this biosensor might be a useful tool for prostate cancer screening. (paper)

  10. Highly Specific Detection of Myostatin Prodomain by an Immunoradiometric Sandwich Assay in Serum of Healthy Individuals and Patients

    Science.gov (United States)

    Widera, Christian; Gottlieb, Jens; Vogel, Arndt; Schmidt, Sebastian; Brandes, Gudrun; Heuft, Hans-Gert; Lichtinghagen, Ralf; Kempf, Tibor; Wollert, Kai C.; Bauersachs, Johann; Heineke, Joerg

    2013-01-01

    Background Myostatin is a muscle derived factor that functions as a negative regulator of skeletal muscle growth. Induction of myostatin expression was observed in rodent models of muscle wasting and in cachectic patients with cancer or pulmonary disease. Therefore, there is an increasing interest to use serum myostatin as a biomarker. Methods We established an immunoradiometric sandwich assay (IRMA), which uses a commercially available chicken polyclonal, affinity purified antibody directed against human myostatin prodomain. We determined the serum concentrations of myostatin prodomain in 249 healthy individuals as well as 169 patients with heart failure, 53 patients with cancer and 44 patients with chronic pulmonary disease. Results The IRMA had a detection limit of 0.7ng/ml, an intraassay imprecision of ≤14.1% and an interassay imprecision of ≤ 18.9%. The specificity of our assay was demonstrated by size exclusion chromatography, detection of myostatin by Western-blotting and a SMAD-dependent transcriptional-reporter assay in the signal-rich serum fractions, as well as lack of interference by unspecific substances like albumin, hemoglobin or lipids. Myostatin prodomain was stable at room temperature and resistant to freeze-thaw cycles. Apparently healthy individuals over the age of 55 had a median myostatin prodomain serum concentration of 3.9ng/ml (25th-75th percentiles, 2-7ng/ml) and we could not detect increased levels in patients with stable chronic heart failure or cancer related weight loss. In contrast, we found strongly elevated concentrations of myostatin prodomain (median 26.9ng/ml, 25th-75th percentiles, 7-100ng/ml) in the serum of underweight patients with chronic pulmonary disease. Conclusions We established a highly specific IRMA for the quantification of myostatin prodomain concentration in human serum. Our assay could be useful to study myostatin as a biomarker for example in patients with chronic pulmonary disease, as we detected highly

  11. Detection of tumor cell-specific mRNA and protein in exosome-like microvesicles from blood and saliva.

    Science.gov (United States)

    Yang, Jieping; Wei, Fang; Schafer, Christopher; Wong, David T W

    2014-01-01

    The discovery of disease-specific biomarkers in oral fluids has revealed a new dimension in molecular diagnostics. Recent studies have reported the mechanistic involvement of tumor cells derived mediators, such as exosomes, in the development of saliva-based mRNA biomarkers. To further our understanding of the origins of disease-induced salivary biomarkers, we here evaluated the hypothesis that tumor-shed secretory lipidic vesicles called exosome-like microvesicles (ELMs) that serve as protective carriers of tissue-specific information, mRNAs, and proteins, throughout the vasculature and bodily fluids. RNA content was analyzed in cell free-saliva and ELM-enriched fractions of saliva. Our data confirmed that the majority of extracellular RNAs (exRNAs) in saliva were encapsulated within ELMs. Nude mice implanted with human lung cancer H460 cells expressing hCD63-GFP were used to follow the circulation of tumor cell specific protein and mRNA in the form of ELMs in vivo. We were able to identify human GAPDH mRNA in ELMs of blood and saliva of tumor bearing mice using nested RT-qPCR. ELMs positive for hCD63-GFP were detected in the saliva and blood of tumor bearing mice as well as using electric field-induced release and measurement (EFIRM). Altogether, our results demonstrate that ELMs carry tumor cell-specific mRNA and protein from blood to saliva in a xenografted mouse model of human lung cancer. These results therefore strengthen the link between distal tumor progression and the biomarker discovery of saliva through the ELMs.

  12. Detection of tumor cell-specific mRNA and protein in exosome-like microvesicles from blood and saliva.

    Directory of Open Access Journals (Sweden)

    Jieping Yang

    Full Text Available The discovery of disease-specific biomarkers in oral fluids has revealed a new dimension in molecular diagnostics. Recent studies have reported the mechanistic involvement of tumor cells derived mediators, such as exosomes, in the development of saliva-based mRNA biomarkers. To further our understanding of the origins of disease-induced salivary biomarkers, we here evaluated the hypothesis that tumor-shed secretory lipidic vesicles called exosome-like microvesicles (ELMs that serve as protective carriers of tissue-specific information, mRNAs, and proteins, throughout the vasculature and bodily fluids. RNA content was analyzed in cell free-saliva and ELM-enriched fractions of saliva. Our data confirmed that the majority of extracellular RNAs (exRNAs in saliva were encapsulated within ELMs. Nude mice implanted with human lung cancer H460 cells expressing hCD63-GFP were used to follow the circulation of tumor cell specific protein and mRNA in the form of ELMs in vivo. We were able to identify human GAPDH mRNA in ELMs of blood and saliva of tumor bearing mice using nested RT-qPCR. ELMs positive for hCD63-GFP were detected in the saliva and blood of tumor bearing mice as well as using electric field-induced release and measurement (EFIRM. Altogether, our results demonstrate that ELMs carry tumor cell-specific mRNA and protein from blood to saliva in a xenografted mouse model of human lung cancer. These results therefore strengthen the link between distal tumor progression and the biomarker discovery of saliva through the ELMs.

  13. Fluorescent quenching-based quantitative detection of specific DNA/RNA using a BODIPY® FL-labeled probe or primer

    Science.gov (United States)

    Kurata, Shinya; Kanagawa, Takahiro; Yamada, Kazutaka; Torimura, Masaki; Yokomaku, Toyokazu; Kamagata, Yoichi; Kurane, Ryuichiro

    2001-01-01

    We have developed a simple method for the quantitative detection of specific DNA or RNA molecules based on the finding that BODIPY® FL fluorescence was quenched by its interaction with a uniquely positioned guanine. This approach makes use of an oligonucleotide probe or primer containing a BODIPY® FL-modified cytosine at its 5′-end. When such a probe was hybridized with a target DNA, its fluorescence was quenched by the guanine in the target, complementary to the modified cytosine, and the quench rate was proportional to the amount of target DNA. This widely applicable technique will be used directly with larger samples or in conjunction with the polymerase chain reaction to quantify small DNA samples. PMID:11239011

  14. Limitations in SELDI-TOF MS whole serum proteomic profiling with IMAC surface to specifically detect colorectal cancer

    International Nuclear Information System (INIS)

    Wang, Qi; Gu, Jin; Shen, Jing; Li, Zhen-fu; Jie, Jian-zheng; Wang, Wen-yue; Wang, Jin; Zhang, Zhong-tao; Li, Zhi-xia; Yan, Li

    2009-01-01

    Surface enhanced laser desorption and ionization time-of-flight mass spectrometry (SELDI-TOF-MS) analysis on serum samples was reported to be able to detect colorectal cancer (CRC) from normal or control patients. We carried out a validation study of a SELDI-TOF MS approach with IMAC surface sample processing to identify CRC. A retrospective cohort of 338 serum samples including 154 CRCs, 67 control cancers and 117 non-cancerous conditions was profiled using SELDI-TOF-MS. No CRC 'specific' classifier was found. However, a classifier consisting of two protein peaks separates cancer from non-cancerous conditions with high accuracy. In this study, the SELDI-TOF-MS-based protein expression profiling approach did not perform to identify CRC. However, this technique is promising in distinguishing patients with cancer from a non-cancerous population; it may be useful for monitoring recurrence of CRC after treatment

  15. Development of specific oligonucleotide probes for the identification and in situ detection of hydrocarbon-degrading Alcanivorax strains.

    Science.gov (United States)

    Syutsubo, K; Kishira, H; Harayama, S

    2001-06-01

    The genus Alcanivorax comprises diverse hydrocarbon-degrading marine bacteria. Novel 16S rRNA-targeted oligonucleotide DNA probes (ALV735 and ALV735-b) were developed to quantify two subgroups of the Alcanivorax/Fundibacter group by fluorescence in situ hybridization (FISH), and the conditions for the single-mismatch discrimination of the probes were optimized. The specificity of the probes was improved further using a singly mismatched oligonucleotide as a competitor. The growth of Alcanivorax cells in crude oil-contaminated sea water under the biostimulation condition was investigated by FISH with the probe ALV735, which targeted the main cluster of the Alcanivorax/Fundibacter group. The size of the Alcanivorax population increased with increasing incubation time and accounted for 91% of the 4',6-diamidino-2-phenylindole (DAPI) count after incubation for 2 weeks. The probes developed in this study are useful for detecting Alcanivorax populations in petroleum hydrocarbon-degrading microbial consortia.

  16. How Well Can We Detect Lineage-Specific Diversification-Rate Shifts? A Simulation Study of Sequential AIC Methods.

    Science.gov (United States)

    May, Michael R; Moore, Brian R

    2016-11-01

    Evolutionary biologists have long been fascinated by the extreme differences in species numbers across branches of the Tree of Life. This has motivated the development of statistical methods for detecting shifts in the rate of lineage diversification across the branches of phylogenic trees. One of the most frequently used methods, MEDUSA, explores a set of diversification-rate models, where each model assigns branches of the phylogeny to a set of diversification-rate categories. Each model is first fit to the data, and the Akaike information criterion (AIC) is then used to identify the optimal diversification model. Surprisingly, the statistical behavior of this popular method is uncharacterized, which is a concern in light of: (1) the poor performance of the AIC as a means of choosing among models in other phylogenetic contexts; (2) the ad hoc algorithm used to visit diversification models, and; (3) errors that we reveal in the likelihood function used to fit diversification models to the phylogenetic data. Here, we perform an extensive simulation study demonstrating that MEDUSA (1) has a high false-discovery rate (on average, spurious diversification-rate shifts are identified [Formula: see text] of the time), and (2) provides biased estimates of diversification-rate parameters. Understanding the statistical behavior of MEDUSA is critical both to empirical researchers-in order to clarify whether these methods can make reliable inferences from empirical datasets-and to theoretical biologists-in order to clarify the specific problems that need to be solved in order to develop more reliable approaches for detecting shifts in the rate of lineage diversification. [Akaike information criterion; extinction; lineage-specific diversification rates; phylogenetic model selection; speciation.]. © The Author(s) 2016. Published by Oxford University Press, on behalf of the Society of Systematic Biologists.

  17. Heterologous Coproduction of Enterocin A and Pediocin PA-1 by Lactococcus lactis: Detection by Specific Peptide-Directed Antibodies

    Science.gov (United States)

    Martínez, José M.; Kok, Jan; Sanders, Jan W.; Hernández, Pablo E.

    2000-01-01

    Antibodies against enterocin A were obtained by immunization of rabbits with synthetic peptides PH4 and PH5 designed, respectively, on the N- and C-terminal amino acid sequences of enterocin A and conjugated to the carrier protein KLH. Anti-PH4-KLH antibodies not only recognized enterocin A but also pediocin PA-1, enterocin P, and sakacin A, three bacteriocins which share the N-terminal class IIa consensus motif (YGNGVXC) that is contained in the sequence of the peptide PH4. In contrast, anti-PH5-KLH antibodies only reacted with enterocin A because the amino acid sequences of the C-terminal parts of class IIa bacteriocins are highly variable. Enterocin A and/or pediocin PA-1 structural and immunity genes were introduced in Lactococcus lactis IL1403 to achieve (co)production of the bacteriocins. The level of production of the two bacteriocins was significantly lower than that obtained by the wild-type producers, a fact that suggests a low efficiency of transport and/or maturation of these bacteriocins by the chromosomally encoded bacteriocin translocation machinery of IL1403. Despite the low production levels, both bacteriocins could be specifically detected and quantified with the anti-PH5-KLH (anti-enterocin A) antibodies isolated in this study and the anti-PH2-KLH (anti-pediocin PA-1) antibodies previously generated (J. M. Martínez, M. I. Martínez, A. M. Suárez, C. Herranz, P. Casaus, L. M. Cintas, J. M. Rodríguez, and P. E. Hernández, Appl. Environ. Microbiol. 64:4536–4545, 1998). In this work, the availability of antibodies for the specific detection and quantification of enterocin A and pediocin PA-1 was crucial to demonstrate coproduction of both bacteriocins by L. lactis IL1403(pJM04), because indicator strains that are selectively inhibited by each bacteriocin are not available. PMID:10919819

  18. Sensitive and Specific Biomimetic Lipid Coated Microfluidics to Isolate Viable Circulating Tumor Cells and Microemboli for Cancer Detection.

    Directory of Open Access Journals (Sweden)

    Jia-Yang Chen

    Full Text Available Here we presented a simple and effective membrane mimetic microfluidic device with antibody conjugated supported lipid bilayer (SLB "smart coating" to capture viable circulating tumor cells (CTCs and circulating tumor microemboli (CTM directly from whole blood of all stage clinical cancer patients. The non-covalently bound SLB was able to promote dynamic clustering of lipid-tethered antibodies to CTC antigens and minimized non-specific blood cells retention through its non-fouling nature. A gentle flow further flushed away loosely-bound blood cells to achieve high purity of CTCs, and a stream of air foam injected disintegrate the SLB assemblies to release intact and viable CTCs from the chip. Human blood spiked cancer cell line test showed the ~95% overall efficiency to recover both CTCs and CTMs. Live/dead assay showed that at least 86% of recovered cells maintain viability. By using 2 mL of peripheral blood, the CTCs and CTMs counts of 63 healthy and colorectal cancer donors were positively correlated with the cancer progression. In summary, a simple and effective strategy utilizing biomimetic principle was developed to retrieve viable CTCs for enumeration, molecular analysis, as well as ex vivo culture over weeks. Due to the high sensitivity and specificity, it is the first time to show the high detection rates and quantity of CTCs in non-metastatic cancer patients. This work offers the values in both early cancer detection and prognosis of CTC and provides an accurate non-invasive strategy for routine clinical investigation on CTCs.

  19. Ion-channel genosensor for the detection of specific DNA sequences derived from Plum Pox Virus in plant extracts.

    Science.gov (United States)

    Malecka, Kamila; Michalczuk, Lech; Radecka, Hanna; Radecki, Jerzy

    2014-10-09

    A DNA biosensor for detection of specific oligonucleotides sequences of Plum Pox Virus (PPV) in plant extracts and buffer is proposed. The working principles of a genosensor are based on the ion-channel mechanism. The NH2-ssDNA probe was deposited onto a glassy carbon electrode surface to form an amide bond between the carboxyl group of oxidized electrode surface and amino group from ssDNA probe. The analytical signals generated as a result of hybridization were registered in Osteryoung square wave voltammetry in the presence of [Fe(CN)6]3-/4- as a redox marker. The 22-mer and 42-mer complementary ssDNA sequences derived from PPV and DNA samples from plants infected with PPV were used as targets. Similar detection limits of 2.4 pM (31.0 pg/mL) and 2.3 pM (29.5 pg/mL) in the concentration range 1-8 pM were observed in the presence of the 22-mer ssDNA and 42-mer complementary ssDNA sequences of PPV, respectively. The genosensor was capable of discriminating between samples consisting of extracts from healthy plants and leaf extracts from infected plants in the concentration range 10-50 pg/mL. The detection limit was 12.8 pg/mL. The genosensor displayed good selectivity and sensitivity. The 20-mer partially complementary DNA sequences with four complementary bases and DNA samples from healthy plants used as negative controls generated low signal.

  20. Design of Tail-Clamp Peptide Nucleic Acid Tethered with Azobenzene Linker for Sequence-Specific Detection of Homopurine DNA

    Directory of Open Access Journals (Sweden)

    Shinjiro Sawada

    2017-10-01

    Full Text Available DNA carries genetic information in its sequence of bases. Synthetic oligonucleotides that can sequence-specifically recognize a target gene sequence are a useful tool for regulating gene expression or detecting target genes. Among the many synthetic oligonucleotides, tail-clamp peptide nucleic acid (TC-PNA offers advantages since it has two homopyrimidine PNA strands connected via a flexible ethylene glycol-type linker that can recognize complementary homopurine sequences via Watson-Crick and Hoogsteen base pairings and form thermally-stable PNA/PNA/DNA triplex structures. Here, we synthesized a series of TC-PNAs that can possess different lengths of azobenzene-containing linkers and studied their binding behaviours to homopurine single-stranded DNA. Introduction of azobenzene at the N-terminus amine of PNA increased the thermal stability of PNA-DNA duplexes. Further extension of the homopyrimidine PNA strand at the N-terminus of PNA-AZO further increased the binding stability of the PNA/DNA/PNA triplex to the target homopurine sequence; however, it induced TC-PNA/DNA/TC-PNA complex formation. Among these TC-PNAs, 9W5H-C4-AZO consisting of nine Watson-Crick bases and five Hoogsteen bases tethered with a beta-alanine conjugated azobenzene linker gave a stable 1:1 TC-PNA/ssDNA complex and exhibited good mismatch recognition. Our design for TC-PNA-AZO can be utilized for detecting homopurine sequences in various genes.

  1. Sensitivity and specificity of a nested polymerase chain reaction for detection of lentivirus infection in lions (Panthera leo).

    Science.gov (United States)

    Adams, Hayley; van Vuuren, Moritz; Kania, Stephen; Bosman, Anna-Mari; Keet, Dewald; New, John; Kennedy, Melissa

    2010-12-01

    Feline immunodeficiency virus (FIV) is a lentivirus in the Retroviridae family that causes lifelong infection in domestic cats. The lentivirus of African lions (Panthera leo), referred to as FIVple, is endemic in certain lion populations in eastern and southern Africa. Lentivirus infection leads to immunologic dysfunction and immunosuppressive disease in domestic cats; however, little is known about the pathogenic effects of infection in lions, nor about the epidemiologic impact on free-ranging and captive populations. Whole blood and serum samples were collected opportunistically from free-ranging lions in Kruger National Park, Republic of South Africa (RSA). Whole blood and serum samples were also collected from captive wild lions in the RSA. A nested polymerase chain reaction (PCR) assay for detection of FIV was performed on all whole blood samples. In addition, serum samples were tested for cross-reactive antibodies to domestic feline lentivirus antigens and puma lentivirus synthetic envelope peptide antigen. The PCR assay successfully amplified the lion lentivirus from African lions. The relative sensitivity and relative specificity were 79% and 100%, respectively, and the positive and negative predictive values were 100% and 67%, respectively. This research represents the first study to compare genetic material with antibody-based methods of lentivirus detection on lions in RSA. Using PCR as an additional diagnostic test for FIV in lions will increase screening sensitivity and will allow viral characterization among circulating isolates and monitoring of changes in the viral epidemiology within geographic regions and populations over time.

  2. Label-Free Electrochemical Detection of the Specific Oligonucleotide Sequence of Dengue Virus Type 1 on Pencil Graphite Electrodes

    Science.gov (United States)

    Souza, Elaine; Nascimento, Gustavo; Santana, Nataly; Ferreira, Danielly; Lima, Manoel; Natividade, Edna; Martins, Danyelly; Lima-Filho, José

    2011-01-01

    A biosensor that relies on the adsorption immobilization of the 18-mer single-stranded nucleic acid related to dengue virus gene 1 on activated pencil graphite was developed. Hybridization between the probe and its complementary oligonucleotides (the target) was investigated by monitoring guanine oxidation by differential pulse voltammetry (DPV). The pencil graphite electrode was made of ordinary pencil lead (type 4B). The polished surface of the working electrode was activated by applying a potential of 1.8 V for 5 min. Afterward, the dengue oligonucleotides probe was immobilized on the activated electrode by applying 0.5 V to the electrode in 0.5 M acetate buffer (pH 5.0) for 5 min. The hybridization process was carried out by incubating at the annealing temperature of the oligonucleotides. A time of five minutes and concentration of 1 μM were found to be the optimal conditions for probe immobilization. The electrochemical detection of annealing between the DNA probe (TS-1P) immobilized on the modified electrode, and the target (TS-1T) was achieved. The target could be quantified in a range from 1 to 40 nM with good linearity and a detection limit of 0.92 nM. The specificity of the electrochemical biosensor was tested using non-complementary sequences of dengue virus 2 and 3. PMID:22163916

  3. Detection of zoonotic and livestock-specific assemblages of Giardia duodenalis in free-living wild lizards

    Directory of Open Access Journals (Sweden)

    Aurora Reboredo-Fernández

    Full Text Available Abstract Giardia duodenalis is a zoonotic parasite that infects the gut of a wide range of vertebrates, including numerous wildlife species. However, little is known about this protozoan parasite in reptiles. Fecal samples from 31 wild lizards were collected in Galicia (northwest Spain and screened for the presence of Giardia by PCR amplification and sequencing of the ITS1-5.8S-ITS2 region in the ribosomal unit. This allowed detection of the parasite in 5 samples (16.1%, and enabled identification of G. duodenalis assemblage A2 in two samples of Iberian rock lizard (Iberolacerta monticola, G. duodenalis assemblage B in other two samples of I. monticola, and G. duodenalis assemblage E in one sample of Bocage’s wall lizard (Podarcis bocagei. The results obtained after PCR amplification and sequencing of the SSU-rDNA gene confirmed the presence of G. duodenalis assemblage A in two samples of I. monticola. This is the first report of G. duodenalis in free-living lizards, although further studies are needed to distinguish between actual infection and mechanical dissemination of cysts. The detection of zoonotic and livestock-specific assemblages of G. duodenalis demonstrates the wide environmental contamination by this parasite, possibly due to human activities.

  4. Prostate-specific membrane antigen PET/MRI validation of MR textural analysis for detection of transition zone prostate cancer

    International Nuclear Information System (INIS)

    Bates, Anthony; Miles, Kenneth

    2017-01-01

    To validate MR textural analysis (MRTA) for detection of transition zone (TZ) prostate cancer through comparison with co-registered prostate-specific membrane antigen (PSMA) PET-MR. Retrospective analysis was performed for 30 men who underwent simultaneous PSMA PET-MR imaging for staging of prostate cancer. Thirty texture features were derived from each manually contoured T2-weighted, transaxial, prostatic TZ using texture analysis software that applies a spatial band-pass filter and quantifies texture through histogram analysis. Texture features of the TZ were compared to PSMA expression on the corresponding PET images. The Benjamini-Hochberg correction controlled the false discovery rate at <5%. Eighty-eight T2-weighted images in 18 patients demonstrated abnormal PSMA expression within the TZ on PET-MR. 123 images were PSMA negative. Based on the corrected p-value of 0.005, significant differences between PSMA positive and negative slices were found for 16 texture parameters: Standard deviation and mean of positive pixels for all spatial filters (p = <0.0001 for both at all spatial scaling factor (SSF) values) and mean intensity following filtration for SSF 3-6 mm (p = 0.0002-0.0018). Abnormal expression of PSMA within the TZ is associated with altered texture on T2-weighted MR, providing validation of MRTA for the detection of TZ prostate cancer. (orig.)

  5. Prostate-specific membrane antigen PET/MRI validation of MR textural analysis for detection of transition zone prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bates, Anthony [Princess Alexandra Hospital, Brisbane (Australia); Miles, Kenneth [Princess Alexandra Hospital, Department of Diagnostic Radiology, Brisbane, QLD (Australia); University College London, Institute of Nuclear Medicine, London (United Kingdom)

    2017-12-15

    To validate MR textural analysis (MRTA) for detection of transition zone (TZ) prostate cancer through comparison with co-registered prostate-specific membrane antigen (PSMA) PET-MR. Retrospective analysis was performed for 30 men who underwent simultaneous PSMA PET-MR imaging for staging of prostate cancer. Thirty texture features were derived from each manually contoured T2-weighted, transaxial, prostatic TZ using texture analysis software that applies a spatial band-pass filter and quantifies texture through histogram analysis. Texture features of the TZ were compared to PSMA expression on the corresponding PET images. The Benjamini-Hochberg correction controlled the false discovery rate at <5%. Eighty-eight T2-weighted images in 18 patients demonstrated abnormal PSMA expression within the TZ on PET-MR. 123 images were PSMA negative. Based on the corrected p-value of 0.005, significant differences between PSMA positive and negative slices were found for 16 texture parameters: Standard deviation and mean of positive pixels for all spatial filters (p = <0.0001 for both at all spatial scaling factor (SSF) values) and mean intensity following filtration for SSF 3-6 mm (p = 0.0002-0.0018). Abnormal expression of PSMA within the TZ is associated with altered texture on T2-weighted MR, providing validation of MRTA for the detection of TZ prostate cancer. (orig.)

  6. Paraneoplastic antigen Ma2 autoantibodies as specific blood biomarkers for detection of early recurrence of small intestine neuroendocrine tumors.

    Directory of Open Access Journals (Sweden)

    Tao Cui

    Full Text Available BACKGROUND: Small intestine neuroendocrine tumors (SI-NETs belong to a rare group of cancers. Most patients have developed metastatic disease at the time of diagnosis, for which there is currently no cure. The delay in diagnosis is a major issue in the clinical management of the patients and new markers are urgently needed. We have previously identified paraneoplastic antigen Ma2 (PNMA2 as a novel SI-NET tissue biomarker. Therefore, we evaluated whether Ma2 autoantibodies detection in the blood stream is useful for the clinical diagnosis and recurrence of SI-NETs. METHODOLOGY/PRINCIPAL FINDINGS: A novel indirect ELISA was set up to detect Ma2 autoantibodies in blood samples of patients with SI-NET at different stages of disease. The analysis was extended to include typical and atypical lung carcinoids (TLC and ALC, to evaluate whether Ma2 autoantibodies in the blood stream become a general biomarker for NETs. In total, 124 blood samples of SI-NET patients at different stages of disease were included in the study. The novel Ma2 autoantibody ELISA showed high sensitivity, specificity and accuracy with ROC curve analysis underlying an area between 0.734 and 0.816. Ma2 autoantibodies in the blood from SI-NET patients were verified by western blot and sequential immunoprecipitation. Serum antibodies of patients stain Ma2 in the tumor tissue and neurons. We observed that SI-NET patients expressing Ma2 autoantibody levels below the cutoff had a longer progression and recurrence-free survival compared to those with higher titer. We also detected higher levels of Ma2 autoantibodies in blood samples from TLC and ALC patients than from healthy controls, as previously shown in small cell lung carcinoma samples. CONCLUSION: Here we show that high Ma2 autoantibody titer in the blood of SI-NET patients is a sensitive and specific biomarker, superior to chromogranin A (CgA for the risk of recurrence after radical operation of these tumors.

  7. Grafting of a peptide probe for Prostate-Specific Antigen detection using diazonium electroreduction and click chemistry.

    Science.gov (United States)

    Strzemińska, I; Sainte Rose Fanchine, S; Anquetin, G; Reisberg, S; Noël, V; Pham, M C; Piro, B

    2016-07-15

    The main objective of this work was to validate a label-free electrochemical method of protein detection using peptides as capture probes. As a proof-of-concept, we used a 7 amino acids sequence (HSSKLQL) specific for Prostate Specific Antigen. We investigated various electrografting conditions of two anilines (2-[(4-aminophenyl)sulfanyl]-8-hydroxy-1,4-naphthoquinone and 4-azidoaniline) further converted in situ into their corresponding diazonium salts on glassy carbon electrodes. It was demonstrated that the best method to obtain a mixed layer is the simultaneous electroreduction of the two diazonium salts. 4-azidoaniline was used to covalently immobilize the ethynyl-functionalized peptide probe by click coupling, and the hydroxynaphthoquinone derivative plays the role of electrochemical transducer of the peptide-protein recognition. The proteolytic activity of PSA towards a small peptide substrate carrying streptavidin at its distal end was also investigated to design an original sensing architecture leading to a reagentless, label free, and "signal-on" PSA sensor. Without optimization, the limit of quantification can be estimated in the nM to pM range. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. An Intelligent Clinical Decision Support System for Patient-Specific Predictions to Improve Cervical Intraepithelial Neoplasia Detection

    Directory of Open Access Journals (Sweden)

    Panagiotis Bountris

    2014-01-01

    Full Text Available Nowadays, there are molecular biology techniques providing information related to cervical cancer and its cause: the human Papillomavirus (HPV, including DNA microarrays identifying HPV subtypes, mRNA techniques such as nucleic acid based amplification or flow cytometry identifying E6/E7 oncogenes, and immunocytochemistry techniques such as overexpression of p16. Each one of these techniques has its own performance, limitations and advantages, thus a combinatorial approach via computational intelligence methods could exploit the benefits of each method and produce more accurate results. In this article we propose a clinical decision support system (CDSS, composed by artificial neural networks, intelligently combining the results of classic and ancillary techniques for diagnostic accuracy improvement. We evaluated this method on 740 cases with complete series of cytological assessment, molecular tests, and colposcopy examination. The CDSS demonstrated high sensitivity (89.4%, high specificity (97.1%, high positive predictive value (89.4%, and high negative predictive value (97.1%, for detecting cervical intraepithelial neoplasia grade 2 or worse (CIN2+. In comparison to the tests involved in this study and their combinations, the CDSS produced the most balanced results in terms of sensitivity, specificity, PPV, and NPV. The proposed system may reduce the referral rate for colposcopy and guide personalised management and therapeutic interventions.

  9. Detection of bacterial soft-rot of crown imperial caused by Pectobacterium carotovorum subsp. carotovorum using specific PCR primers

    Directory of Open Access Journals (Sweden)

    E. Mahmoudi

    2007-08-01

    Full Text Available Pectobacterium is one of the major destructive causal agent in most crop plants throughout the world. During a survey in spring of 2005 in the rangeland of Kermanshah and Isfahan, provinces of Iran, samples of bulbs and stems of crown imperial with brown spot and soft rot were collected. Eight strains of pectolytic Erwinia were isolated and purified from these samples. Phenotypic tests indicated that the strains were gram-negative, facultative anaerobic, rod shaped, motile with peritrichous flagella. They were oxidase negative, catalase positive and also able to macerate potato slices. Pathogenicity of all the strains were confirmed on corn, philodendron and crown imperial by inoculation of these crops with a bacterial suspension and reisolation of the strain from symptomatic tissues. A pair of specific PCR primers was used to detect these bacterial strains. The primer set (EXPCCF/EXPCCR amplified a single fragment of the expected size (0.55 kb from genomic DNA of all strains used in this study. In nested PCR, the primer set (INPCCR/INPCCF amplified the expected single fragment (0.4 kb from the PCR product of first PCR amplification. On the basis of the biochemical and phenotypic characteristics and PCR amplification by the specific PCR primers, these strains were identified as Pectobacterium carotovorum subsp. carotovorum. This is the first report of occurrence of crown imperial bacterial soft-rot in Iran.

  10. Statistically based splicing detection reveals neural enrichment and tissue-specific induction of circular RNA during human fetal development.

    Science.gov (United States)

    Szabo, Linda; Morey, Robert; Palpant, Nathan J; Wang, Peter L; Afari, Nastaran; Jiang, Chuan; Parast, Mana M; Murry, Charles E; Laurent, Louise C; Salzman, Julia

    2015-06-16

    The pervasive expression of circular RNA is a recently discovered feature of gene expression in highly diverged eukaryotes, but the functions of most circular RNAs are still unknown. Computational methods to discover and quantify circular RNA are essential. Moreover, discovering biological contexts where circular RNAs are regulated will shed light on potential functional roles they may play. We present a new algorithm that increases the sensitivity and specificity of circular RNA detection by discovering and quantifying circular and linear RNA splicing events at both annotated and un-annotated exon boundaries, including intergenic regions of the genome, with high statistical confidence. Unlike approaches that rely on read count and exon homology to determine confidence in prediction of circular RNA expression, our algorithm uses a statistical approach. Using our algorithm, we unveiled striking induction of general and tissue-specific circular RNAs, including in the heart and lung, during human fetal development. We discover regions of the human fetal brain, such as the frontal cortex, with marked enrichment for genes where circular RNA isoforms are dominant. The vast majority of circular RNA production occurs at major spliceosome splice sites; however, we find the first examples of developmentally induced circular RNAs processed by the minor spliceosome, and an enriched propensity of minor spliceosome donors to splice into circular RNA at un-annotated, rather than annotated, exons. Together, these results suggest a potentially significant role for circular RNA in human development.

  11. An intelligent clinical decision support system for patient-specific predictions to improve cervical intraepithelial neoplasia detection.

    Science.gov (United States)

    Bountris, Panagiotis; Haritou, Maria; Pouliakis, Abraham; Margari, Niki; Kyrgiou, Maria; Spathis, Aris; Pappas, Asimakis; Panayiotides, Ioannis; Paraskevaidis, Evangelos A; Karakitsos, Petros; Koutsouris, Dimitrios-Dionyssios

    2014-01-01

    Nowadays, there are molecular biology techniques providing information related to cervical cancer and its cause: the human Papillomavirus (HPV), including DNA microarrays identifying HPV subtypes, mRNA techniques such as nucleic acid based amplification or flow cytometry identifying E6/E7 oncogenes, and immunocytochemistry techniques such as overexpression of p16. Each one of these techniques has its own performance, limitations and advantages, thus a combinatorial approach via computational intelligence methods could exploit the benefits of each method and produce more accurate results. In this article we propose a clinical decision support system (CDSS), composed by artificial neural networks, intelligently combining the results of classic and ancillary techniques for diagnostic accuracy improvement. We evaluated this method on 740 cases with complete series of cytological assessment, molecular tests, and colposcopy examination. The CDSS demonstrated high sensitivity (89.4%), high specificity (97.1%), high positive predictive value (89.4%), and high negative predictive value (97.1%), for detecting cervical intraepithelial neoplasia grade 2 or worse (CIN2+). In comparison to the tests involved in this study and their combinations, the CDSS produced the most balanced results in terms of sensitivity, specificity, PPV, and NPV. The proposed system may reduce the referral rate for colposcopy and guide personalised management and therapeutic interventions.

  12. High specificity of spot urinary free metanephrines in diagnosis and prognosis of pheochromocytomas and paragangliomas by HPLC with electrochemical detection.

    Science.gov (United States)

    Zuo, Ming; Zhen, Qianna; Zhang, Xiaoqing; Zou, Wenbi; Yang, Xiangchun; Tian, Gang; Shi, Zhenghu; Li, Qifu; Ding, Min

    2018-03-01

    The metanephrines (MNs) in plasma and urine were proposed as biomarkers for the diagnosis of pheochromocytomas and paragangliomas (PPGLs). However, plasma free MNs and 24h urinary fractionated MNs were not satisfactory enough in specificity for the diagnosis of PPGLs. Moreover, the collection of 24h urine was inconvenient. This work examined the diagnostic and prognostic efficiency of free MNs in spot urine for PPGLs. We measured free MNs concentration in spot urine and plasma of 28 PPGLs patients and 155 control subjects by HPLC with electrochemical detection. Postoperative free MNs levels in spot urine and plasma of 14 PPGLs patients were also determined. Creatinine (Cr) concentration was used for the correction of urine volume. The specificity of spot urinary free MNs/Cr in the diagnosis of PPGLs was significantly higher than that of plasma free MNs [normetanephrine (NMN), 98.7% (95.4%-99.8%) vs 93.0% (87.4%-96.6%); metanephrine (MN), 93.6% (88.5%-96.9%) vs 84.5% (77.5%-90.0%)]. Meanwhile, the positive likelihood ratios for spot urinary free NMN/Cr and MN/Cr were 69.21 and 13.29, compared with 12.68 and 5.30 for plasma free NMN and MN, respectively. For the PPGLs patients underwent surgery, the plasma free MNs level appeared an abnormal elevation and yielded false-positive results for some patients. Our findings were validated in an independent cohort, resulting in the specificity of 100% for both urinary free NMN/Cr and MN/Cr, and 97.3% and 83.8% for plasma free NMN and MN, respectively. Spot urinary free MNs/Cr, superior to plasma free MNs, presented a promising biomarker for the diagnosis and prognosis of PPGLs. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Detection of Sequence-Specific Tyrosine Nitration of Manganese SOD and SERCA in Cardiovascular Disease and Aging

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Shanqin; Ying, Jia; Jiang, Bingbing; Guo, Wei; Adachi, Takeshi; Sharov, Victor; Lazar, Harold; Menzoian, James; Knyushko, Tanya V.; Bigelow, Diana J.; Schoneich, Christian; Cohen, Richard

    2006-06-01

    Nitration of protein tyrosine residues (nY) is a marker of oxidative stress and may alter the biological activity of the modified proteins. The aim of this study was to develop antibodies towards site-specific nY-modified proteins and to use histochemical and immunoblotting to demonstrate protein nitration in tissues. Affinity-purified polyclonal antibodies towards peptides with known nY sites in MnSOD nY-34 and of two adjacent nY in the sarcoplasmic endoplasmic reticulum calcium ATPase (SERCA2 di-nY-294,295) were developed. Kidneys from rats infused with angiotensin II with known MnSOD nY and aorta from atherosclerotic rabbits and aging rat skeletal and cardiac sarcoplasmic reticulum with known SERCA di-nY were used for positive controls. Staining for MnSOD nY-34 was most intense in distal renal tubules and collecting ducts. Staining of atherosclerotic aorta for SERCA2 di-nY was most intense in atherosclerotic plaques. Aging rat skeletal muscle and atherosclerotic aorta and cardiac atrium from human diabetic patients also stained positively. Staining was decreased by sodium dithionite that chemically reduces nitrotyrosine to aminotyrosine, and the antigenic nY-peptide blocked staining for each respective nY site, but not for the other. As previously demonstrated, immunoblotting failed to detect these modified proteins in whole tissue lysates, but did when the proteins were concentrated. Immunohistochemical staining for specific nY-modified tyrosine residues offers the ability to assess the effects of oxidant stress associated with pathological conditions on individual proteins whose function may be affected in specific tissue sites.

  14. Development of a taqman-based real-time PCR assay for the rapid and specific detection of novel duck- origin goose parvovirus.

    Science.gov (United States)

    Wang, Jianchang; Wang, Jinfeng; Cui, Yuan; Nan, Huizhu; Yuan, Wanzhe

    2017-08-01

    A real-time PCR assay was developed for specific detection of novel duck-origin goose parvovirus (N-GPV), the etiological agent of duck beak atrophy and dwarfism syndrome (BADS). The detection limit of the assay was 10 2 copies. The assay was useful in the prevention and control of BADS. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Extraction and Refinement Strategy for Detection of Autism in 18-Month-Olds: A Guarantee of Higher Sensitivity and Specificity in the Process of Mass Screening

    Science.gov (United States)

    Honda, Hideo; Shimizu, Yasuo; Nitto, Yukari; Imai, Miho; Ozawa, Takeshi; Iwasa, Mitsuaki; Shiga, Keiko; Hira, Tomoko

    2009-01-01

    Background: For early detection of autism, it is difficult to maintain an efficient level of sensitivity and specificity based on observational data from a single screening. The Extraction and Refinement (E&R) Strategy utilizes a public children's health surveillance program to produce maximum efficacy in early detection of autism. In the…

  16. Sensitive and specific detection of classical scrapie prions in the brain of goats by real-time quaking-induced conversion

    Science.gov (United States)

    The real-time quaking-induced conversion (RT-QuIC) is a rapid, specific, and sensitive prion seeding activity detection assay that uses recombinant prion protein (rPrPSen) to detect sub-infectious levels of the abnormal isoforms of the prion protein (PrPSc). Although RT-QuIC has been successfully us...

  17. Specific detection of the genus Serpulina, S-hyodysenteriae and S-pilosicoli in porcine intestines by fluorescent rRNA in situ hybridization

    DEFF Research Database (Denmark)

    Boye, Mette; Jensen, Tim Kåre; Møller, Kristian

    1998-01-01

    , for the detection of Serpulina isolates at genus level as well as for specific detection of S. hyodysenteriae and S. pilosicoli in formalin-fixed colon tissue sections from pigs suffering from swine dysentery and porcine colonic spirochaetosis, respectively. Tissue sections were also used from pigs without any...

  18. Oriented Immobilization of Fab Fragments by Site-Specific Biotinylation at the Conserved Nucleotide Binding Site for Enhanced Antigen Detection.

    Science.gov (United States)

    Mustafaoglu, Nur; Alves, Nathan J; Bilgicer, Basar

    2015-09-08

    Oriented immobilization of antibodies and antibody fragments has become increasingly important as a result of the efforts to reduce the size of diagnostic and sensor devices to miniaturized dimensions for improved accessibility to the end-user. Reduced dimensions of sensor devices necessitate the immobilized antibodies to conserve their antigen binding activity for proper operation. Fab fragments are becoming more commonly used in small-scaled diagnostic devices due to their small size and ease of manufacture. In this study, we used the previously described UV-NBS(Biotin) method to functionalize Fab fragments with IBA-EG11-Biotin linker utilizing UV energy to initiate a photo-cross-linking reaction between the nucleotide binding site (NBS) on the Fab fragment and IBA-Biotin molecule. Our results demonstrate that immobilization of biotinylated Fab fragments via UV-NBS(Biotin) method generated the highest level of immobilized Fab on surfaces when compared to other typical immobilization methods while preserving antigen binding activity. UV-NBS(Biotin) method provided 432-fold, 114-fold, and 29-fold improved antigen detection sensitivity than physical adsorption, NHS-Biotin, and ε-NH3(+), methods, respectively. Additionally, the limit of detection (LOD) for PSA utilizing Fab fragments immobilized via UV-NBS(Biotin) method was significantly lower than that of the other immobilization methods, with an LOD of 0.4 pM PSA. In summary, site-specific biotinylation of Fab fragments without structural damage or loss in antigen binding activity provides a wide range of application potential for UV-NBS immobilization technique across numerous diagnostic devices and nanotechnologies.

  19. [In vitro immunization for the production of antibodies to tetanus toxin and toxoid. 1. Systems for the detection of in vitro synthetized specific immunoglobulins. Strategies of test development].

    Science.gov (United States)

    Kiessig, S T; Jahn, S; Porstmann, T; von Baehr, R

    1987-01-01

    By means of semipurified tetanus toxin for solid phase coating in an enzyme immunoassay (ELISA) for detection of specific IgG and IgM antibodies a detection limit of 0.02 IU per litre was achieved. The addition of serum from animals like horses or goats as inert protein to the dilution medium was omitted to prevent a displacement of human antibodies by antitetanus antibodies present in the animals sera. The specificity of the ELISA was demonstrated by inhibition experiments with soluble antigen and in an ELISA for detection of anti-tetanus toxin antibodies from mice immunized with the toxoid from the different purification steps.

  20. High-specificity detection of rare alleles with Paired-End Low Error Sequencing (PELE-Seq).

    Science.gov (United States)

    Preston, Jessica L; Royall, Ariel E; Randel, Melissa A; Sikkink, Kristin L; Phillips, Patrick C; Johnson, Eric A

    2016-06-14

    Polymorphic loci exist throughout the genomes of a population and provide the raw genetic material needed for a species to adapt to changes in the environment. The minor allele frequencies of rare Single Nucleotide Polymorphisms (SNPs) within a population have been difficult to track with Next-Generation Sequencing (NGS), due to the high error rate of standard methods such as Illumina sequencing. We have developed a wet-lab protocol and variant-calling method that identifies both sequencing and PCR errors, called Paired-End Low Error Sequencing (PELE-Seq). To test the specificity and sensitivity of the PELE-Seq method, we sequenced control E. coli DNA libraries containing known rare alleles present at frequencies ranging from 0.2-0.4 % of the total reads. PELE-Seq had higher specificity and sensitivity than standard libraries. We then used PELE-Seq to characterize rare alleles in a Caenorhabditis remanei nematode worm population before and after laboratory adaptation, and found that minor and rare alleles can undergo large changes in frequency during lab-adaptation. We have developed a method of rare allele detection that mitigates both sequencing and PCR errors, called PELE-Seq. PELE-Seq was evaluated using control E. coli populations and was then used to compare a wild C. remanei population to a lab-adapted population. The PELE-Seq method is ideal for investigating the dynamics of rare alleles in a broad range of reduced-representation sequencing methods, including targeted amplicon sequencing, RAD-Seq, ddRAD, and GBS. PELE-Seq is also well-suited for whole genome sequencing of mitochondria and viruses, and for high-throughput rare mutation screens.

  1. Sensitive and specific peak detection for SELDI-TOF mass spectrometry using a wavelet/neural-network based approach.

    Directory of Open Access Journals (Sweden)

    Vincent A Emanuele

    Full Text Available SELDI-TOF mass spectrometer's compact size and automated, high throughput design have been attractive to clinical researchers, and the platform has seen steady-use in biomarker studies. Despite new algorithms and preprocessing pipelines that have been developed to address reproducibility issues, visual inspection of the results of SELDI spectra preprocessing by the best algorithms still shows miscalled peaks and systematic sources of error. This suggests that there continues to be problems with SELDI preprocessing. In this work, we study the preprocessing of SELDI in detail and introduce improvements. While many algorithms, including the vendor supplied software, can identify peak clusters of specific mass (or m/z in groups of spectra with high specificity and low false discover rate (FDR, the algorithms tend to underperform estimating the exact prevalence and intensity of peaks in those clusters. Thus group differences that at first appear very strong are shown, after careful and laborious hand inspection of the spectra, to be less than significant. Here we introduce a wavelet/neural network based algorithm which mimics what a team of expert, human users would call for peaks in each of several hundred spectra in a typical SELDI clinical study. The wavelet denoising part of the algorithm optimally smoothes the signal in each spectrum according to an improved suite of signal processing algorithms previously reported (the LibSELDI toolbox under development. The neural network part of the algorithm combines those results with the raw signal and a training dataset of expertly called peaks, to call peaks in a test set of spectra with approximately 95% accuracy. The new method was applied to data collected from a study of cervical mucus for the early detection of cervical cancer in HPV infected women. The method shows promise in addressing the ongoing SELDI reproducibility issues.

  2. Simple dipstick assay for the detection of Salmonella typhi-specific IgM antibodies and the evolution of the immune response in patients with typhoid fever

    NARCIS (Netherlands)

    Hatta, Mochammad; Goris, Marga G. A.; Heerkens, Evy; Gooskens, Jairo; Smits, Henk L.

    2002-01-01

    Application of a dipstick assay for the detection of Salmonella typhi-specific IgM antibodies on samples collected from S. typhi or S. paratyphi culture-positive patients at the day of admission to the hospital revealed the presence of specific IgM antibodies in 43.5%, 92.9%, and 100% for samples

  3. Comparison of two enzyme-linked immunosorbent assays and one rapid immunoblot assay for detection of herpes simplex virus type 2-specific antibodies in serum

    NARCIS (Netherlands)

    Groen, J; Van Dijk, G; Niesters, H G; Van Der Meijden, W I; Osterhaus, A D

    The sensitivities and specificities of three immunoassays for the detection of herpes simplex virus type 2 (HSV-2)-specific immunoglobulin G antibodies in serum, including the one-strip rapid immunoblot assay (RIBA; Chiron Corporation) and two indirect enzyme immunosorbent assays (EIA; Gull

  4. To what extent does the anxiety scale of the Four-Dimensional Symptom Questionnaire (4DSQ) detect specific types of anxiety disorder in primary care? A psychometric study

    NARCIS (Netherlands)

    Terluin, B.; Oosterbaan, D.B.; Brouwers, E.P.; Straten, A. van; Ven, P.M. van de; Langerak, W.; Marwijk, H.W.J. van

    2014-01-01

    BACKGROUND: Anxiety scales may help primary care physicians to detect specific anxiety disorders among the many emotionally distressed patients presenting in primary care. The anxiety scale of the Four-Dimensional Symptom Questionnaire (4DSQ) consists of an admixture of symptoms of specific anxiety

  5. To what extent does the anxiety scale of the Four-Dimensional Symptom Questionnaire (4DSQ) detect specific types of anxiety disorder in primary care?

    NARCIS (Netherlands)

    Terluin, B.; Oosterbaan, D.B.; Brouwers, E.P.; van Straten, A.; van de Ven, P.M.; Langerak, W.; van Marwijk, H.W.

    2014-01-01

    Background: Anxiety scales may help primary care physicians to detect specific anxiety disorders among the many emotionally distressed patients presenting in primary care. The anxiety scale of the Four-Dimensional Symptom Questionnaire (4DSQ) consists of an admixture of symptoms of specific anxiety

  6. To what extent does the anxiety scale of the Four Dimensional Symptom Questionnaire (4DSQ) detect specific types of anxiety disorder in primary care? : A psychometric study

    NARCIS (Netherlands)

    Terluin, B.; Oosterbaan, D.B.; Brouwers, E.P.M.; van Straten, A.H.M.; van de Ven, P.; Langerak, W.; van Marwijk, H.W.J.

    2014-01-01

    Background Anxiety scales may help primary care physicians to detect specific anxiety disorders among the many emotionally distressed patients presenting in primary care. The anxiety scale of the Four-Dimensional Symptom Questionnaire (4DSQ) consists of an admixture of symptoms of specific anxiety

  7. The Value of Urine Specific Gravity in Detecting Diabetes Insipidus in a Patient with Uncontrolled Diabetes Mellitus: Urine Specific Gravity in Differential Diagnosis

    OpenAIRE

    Akarsu, Ersin; Buyukhatipoglu, Hakan; Aktaran, Sebnem; Geyik, Ramazan

    2006-01-01

    When a patient with diabetes mellitus presents with worsening polyuria and polydipsia, what is a sensible, cost-effective approach? We report the unique coincidence of type 2 diabetes mellitus and diabetes insipidus. A 46-year-old woman with poorly controlled type 2 diabetes complained of polyuria with a daily output of 5 L. Although urinalysis demonstrated significant glucosuria, diabetes insipidus was suspected owing to a low urine specific gravity (1.008). The low specific gravity persiste...

  8. Sika deer (Cervus nippon)-specific real-time PCR method to detect fraudulent labelling of meat and meat products.

    Science.gov (United States)

    Kaltenbrunner, Maria; Hochegger, Rupert; Cichna-Markl, Margit

    2018-05-08

    Since game meat is more valuable and expensive than meat from domesticated animal species it is a potential target for adulteration. Analytical methods must allow the identification and quantification of meat species to be applicable for the detection of fraudulent labelling. We developed a real-time PCR assay for the authentication of sika deer (Cervus nippon) and products thereof. The primer/probe system amplifies a 71 bp fragment of the kappa-casein precursor gene. Since the target sequence contained only one sika deer-specific base, we introduced a deliberate base mismatch in the forward primer. The real-time PCR assay did not show cross-reactivity with 19 animal and 49 plant species tested. Low cross-reactivity was observed with red deer, fallow deer, reindeer and moose. However, with a ΔCt value of ≥11.79 between sika deer and the cross-reacting species, cross-reactivity will not affect the accuracy of the method. LOD and LOQ, determined by analysing serial dilutions of a DNA extract containing 1% (w/w) sika deer DNA in pig DNA, were 0.3% and 0.5%, respectively. The accuracy was evaluated by analysing DNA mixtures and DNA isolates from meat extract mixtures and meat mixtures. In general, recoveries were in the range from 70 to 130%.

  9. The discovery of putative urine markers for the specific detection of prostate tumor by integrative mining of public genomic profiles.

    Directory of Open Access Journals (Sweden)

    Min Chen

    Full Text Available Urine has emerged as an attractive biofluid for the noninvasive detection of prostate cancer (PCa. There is a strong imperative to discover candidate urinary markers for the clinical diagnosis and prognosis of PCa. The rising flood of various omics profiles presents immense opportunities for the identification of prospective biomarkers. Here we present a simple and efficient strategy to derive candidate urine markers for prostate tumor by mining cancer genomic profiles from public databases. Prostate, bladder and kidney are three major tissues from which cellular matters could be released into urine. To identify urinary markers specific for PCa, upregulated entities that might be shed in exosomes of bladder cancer and kidney cancer are first excluded. Through the ontology-based filtering and further assessment, a reduced list of 19 entities encoding urinary proteins was derived as putative PCa markers. Among them, we have found 10 entities closely associated with the process of tumor cell growth and development by pathway enrichment analysis. Further, using the 10 entities as seeds, we have constructed a protein-protein interaction (PPI subnetwork and suggested a few urine markers as preferred prognostic markers to monitor the invasion and progression of PCa. Our approach is amenable to discover and prioritize potential markers present in a variety of body fluids for a spectrum of human diseases.

  10. Detection of Echinococcus multilocularis by MC-PCR: evaluation of diagnostic sensitivity and specificity without gold standard

    Directory of Open Access Journals (Sweden)

    Helene Wahlström

    2016-03-01

    Full Text Available Introduction: A semi-automated magnetic capture probe-based DNA extraction and real-time PCR method (MC-PCR, allowing for a more efficient large-scale surveillance of Echinococcus multilocularis occurrence, has been developed. The test sensitivity has previously been evaluated using the sedimentation and counting technique (SCT as a gold standard. However, as the sensitivity of the SCT is not 1, test characteristics of the MC-PCR was also evaluated using latent class analysis, a methodology not requiring a gold standard. Materials and methods: Test results, MC-PCR and SCT, from a previous evaluation of the MC-PCR using 177 foxes shot in the spring (n=108 and autumn 2012 (n=69 in high prevalence areas in Switzerland were used. Latent class analysis was used to estimate the test characteristics of the MC-PCR. Although it is not the primary aim of this study, estimates of the test characteristics of the SCT were also obtained. Results and discussion: This study showed that the sensitivity of the MC-PCR was 0.88 [95% posterior credible interval (PCI 0.80–0.93], which was not significantly different than the SCT, 0.83 (95% PCI 0.76–0.88, which is currently considered as the gold standard. The specificity of both tests was high, 0.98 (95% PCI 0.94–0.99 for the MC-PCR and 0.99 (95% PCI 0.99–1 for the SCT. In a previous study, using fox scats from a low prevalence area, the specificity of the MC-PCR was higher, 0.999% (95% PCI 0.997–1. One reason for the lower estimate of the specificity in this study could be that the MC-PCR detects DNA from infected but non-infectious rodents eaten by foxes. When using MC-PCR in low prevalence areas or areas free from the parasite, a positive result in the MC-PCR should be regarded as a true positive. Conclusion: The sensitivity of the MC-PCR (0.88 was comparable to the sensitivity of SCT (0.83.

  11. Novel PET and Near Infrared Imaging Probes for the Specific Detection of Bacterial Infections Associated With Cardiac Devices.

    Science.gov (United States)

    Takemiya, Kiyoko; Ning, Xinghai; Seo, Wonewoo; Wang, Xiaojian; Mohammad, Rafi; Joseph, Giji; Titterington, Jane S; Kraft, Colleen S; Nye, Jonathan A; Murthy, Niren; Goodman, Mark M; Taylor, W Robert

    2018-04-13

    The aim of this study was to develop imaging agents to detect early stage infections in implantable cardiac devices. Bacteria ingest maltodextrins through the specific maltodextrin transporter. We developed probes conjugated with either a fluorescent dye (maltohexaose fluorescent dye probe [MDP]) or a F-18 (F18 fluoromaltohexaose) and determined their usefulness in a model of infections associated with implanted cardiac devices. Stainless steel mock-ups of medical devices were implanted subcutaneously in rats. On post-operative day 4, animals were injected with either Staphylococcus aureus around the mock-ups to induce a relatively mild infection or oil of turpentine to induce noninfectious inflammation. Animals with a sterile implant were used as control subjects. On post-operative day 6, either the MDP or F18 fluoromaltohexaose was injected intravenously, and the animals were scanned with the appropriate imaging device. Additional positron emission tomography imaging studies were performed with F18-fluorodeoxyglucose as a comparison of the specificity of our probes (n = 5 to 9 per group). The accumulation of the MDP in the infected rats was significantly increased at 1 h after injection when compared with the control and noninfectious inflammation groups (intensity ratio 1.54 ± 0.07 vs. 1.26 ± 0.04 and 1.20 ± 0.05, respectively; p F18 fluoromaltohexaose and F18 fluorodeoxyglucose significantly accumulated in the infected area 30 min after the injection (maximum standard uptake value ratio 4.43 ± 0.30 and 4.87 ± 0.28, respectively). In control rats, there was no accumulation of imaging probes near the device. In the noninfectious inflammation rats, no significant accumulation was observed with F18 fluoromaltohexaose, but F18 fluorodeoxyglucose accumulated in the mock-up area (maximum standard uptake value 2.53 ± 0.39 vs. 4.74 ± 0.46, respectively; p < 0.05). Our results indicate that maltohexaose-based imaging probes are potentially useful for the

  12. Gender-specific effects of genetic variants within Th1 and Th17 cell-mediated immune response genes on the risk of developing rheumatoid arthritis.

    Directory of Open Access Journals (Sweden)

    Rafael Cáliz

    Full Text Available The present study was conducted to explore whether single nucleotide polymorphisms (SNPs in Th1 and Th17 cell-mediated immune response genes differentially influence the risk of rheumatoid arthritis (RA in women and men. In phase one, 27 functional/tagging polymorphisms in C-type lectins and MCP-1/CCR2 axis were genotyped in 458 RA patients and 512 controls. Carriers of Dectin-2 rs4264222T allele had an increased risk of RA (OR = 1.47, 95%CI 1.10-1.96 whereas patients harboring the DC-SIGN rs4804803G, MCP-1 rs1024611G, MCP-1 rs13900T and MCP-1 rs4586C alleles had a decreased risk of developing the disease (OR = 0.66, 95%CI 0.49-0.88; OR = 0.66, 95%CI 0.50-0.89; OR = 0.73, 95%CI 0.55-0.97 and OR = 0.68, 95%CI 0.51-0.91. Interestingly, significant gender-specific differences were observed for Dectin-2 rs4264222 and Dectin-2 rs7134303: women carrying the Dectin-2 rs4264222T and Dectin-2 rs7134303G alleles had an increased risk of RA (OR = 1.93, 95%CI 1.34-2.79 and OR = 1.90, 95%CI 1.29-2.80. Also five other SNPs showed significant associations only with one gender: women carrying the MCP-1 rs1024611G, MCP-1 rs13900T and MCP-1 rs4586C alleles had a decreased risk of RA (OR = 0.61, 95%CI 0.43-0.87; OR = 0.67, 95%CI 0.47-0.95 and OR = 0.60, 95%CI 0.42-0.86. In men, carriers of the DC-SIGN rs2287886A allele had an increased risk of RA (OR = 1.70, 95%CI 1.03-2.78, whereas carriers of the DC-SIGN rs4804803G had a decreased risk of developing the disease (OR = 0.53, 95%CI 0.32-0.89. In phase 2, we genotyped these SNPs in 754 RA patients and 519 controls, leading to consistent gender-specific associations for Dectin-2 rs4264222, MCP-1 rs1024611, MCP-1 rs13900 and DC-SIGN rs4804803 polymorphisms in the pooled sample (OR = 1.38, 95%CI 1.08-1.77; OR = 0.74, 95%CI 0.58-0.94; OR = 0.76, 95%CI 0.59-0.97 and OR = 0.56, 95%CI 0.34-0.93. SNP-SNP interaction analysis of significant SNPs also showed a

  13. Development, optimization, and single laboratory validation of an event-specific real-time PCR method for the detection and quantification of Golden Rice 2 using a novel taxon-specific assay.

    Science.gov (United States)

    Jacchia, Sara; Nardini, Elena; Savini, Christian; Petrillo, Mauro; Angers-Loustau, Alexandre; Shim, Jung-Hyun; Trijatmiko, Kurniawan; Kreysa, Joachim; Mazzara, Marco

    2015-02-18

    In this study, we developed, optimized, and in-house validated a real-time PCR method for the event-specific detection and quantification of Golden Rice 2, a genetically modified rice with provitamin A in the grain. We optimized and evaluated the performance of the taxon (targeting rice Phospholipase D α2 gene)- and event (targeting the 3' insert-to-plant DNA junction)-specific assays that compose the method as independent modules, using haploid genome equivalents as unit of measurement. We verified the specificity of the two real-time PCR assays and determined their dynamic range, limit of quantification, limit of detection, and robustness. We also confirmed that the taxon-specific DNA sequence is present in single copy in the rice genome and verified its stability of amplification across 132 rice varieties. A relative quantification experiment evidenced the correct performance of the two assays when used in combination.

  14. Sensitivity and specificity of a new scoring system for diabetic macular oedema detection using a confocal laser imaging system

    Science.gov (United States)

    Tong, L; Ang, A; Vernon, S; Zambarakji, H; Bhan, A; Sung, V; Page, S

    2001-01-01

    AIM—To assess the use of the Heidelberg retina tomograph (HRT) in screening for sight threatening diabetic macular oedema in a hospital diabetic clinic, using a new subjective analysis system (SCORE).
METHODS—200 eyes of 100 consecutive diabetic patients attending a diabetologist's clinic were studied, all eyes had an acuity of 6/9 or better. All patients underwent clinical examination by an ophthalmologist. Using the HRT, one good scan was obtained for each eye centred on the fovea. A System for Classification and Ordering of Retinal Edema (SCORE) was developed using subjective assessment of the colour map and the reflectivity image. The interobserver agreement of using this method to detect macular oedema was assessed by two observers (ophthalmic trainees) who were familiarised with SCORE by studying standard pictures of eyes not in the study. All scans were graded from 0-6 and test positive cases were defined as having a SCORE value of 0-2. The sensitivity of SCORE was assessed by pooling the data with an additional 88 scans of 88 eyes in order to reduce the confidence interval of the index.
RESULTS—12 eyes in eight out of the 100 patients had macular oedema clinically. Three scans in three patients could not be analysed because of poor scan quality. In the additional group of scans 76 out of 88 eyes had macular oedema clinically. The scoring system had a specificity of 99% (95% CI 96-100) and sensitivity of 67% (95% CI 57-76). The predictive value of a negative test was 87% (95% CI 82-99), and that of a positive test was 95% (95% CI 86-99). The mean difference of the SCORE value between two observers was -0.2 (95% CI -0.5 to +0.07).
CONCLUSIONS—These data suggest that SCORE is potentially useful for detecting diabetic macular oedema in hospital diabetic patients.

 PMID:11133709

  15. Development and Evaluation of a PCR and Mass Spectroscopy-based (PCR-MS) Method for Quantitative, Type-specific Detection of Human Papillomavirus

    Science.gov (United States)

    Patel, Divya A.; Shih, Yang-Jen; Newton, Duane W.; Michael, Claire W.; Oeth, Paul A.; Kane, Michael D.; Opipari, Anthony W.; Ruffin, Mack T.; Kalikin, Linda M.; Kurnit, David M.

    2010-01-01

    Knowledge of the central role of high-risk human papillomavirus (HPV) in cervical carcinogenesis, coupled with an emerging need to monitor the efficacy of newly introduced HPV vaccines, warrant development and evaluation of type-specific, quantitative HPV detection methods. In the present study, a prototype PCR and mass spectroscopy (PCR-MS)-based method to detect and quantitate 13 high-risk HPV types is compared to the Hybrid Capture 2 High Risk HPV DNA test (HC2; Digene Corp., Gaithersburg, MD) in 199 cervical scraping samples and to DNA sequencing in 77 cervical tumor samples. High-risk HPV types were detected in 76/77 (98.7%) cervical tumor samples by PCR-MS. Degenerate and type-specific sequencing confirmed the types detected by PCR-MS. In 199 cervical scraping samples, all 13 HPV types were detected by PCR-MS. Eighteen (14.5%) of 124 cervical scraping samples that were positive for high-risk HPV by HC2 were negative by PCR-MS. In all these cases, degenerate DNA sequencing failed to detect any of the 13 high-risk HPV types. Nearly half (46.7%) of the 75 cervical scraping samples that were negative for high-risk HPV by the HC2 assay were positive by PCR-MS. Type-specific sequencing in a subset of these samples confirmed the HPV type detected by PCR-MS. Quantitative PCR-MS results demonstrated that 11/75 (14.7%) samples contained as much HPV copies/cell as HC2-positive samples. These findings suggest that this prototype PCR-MS assay performs at least as well as HC2 for HPV detection, while offering the additional, unique advantages of type-specific identification and quantitation. Further validation work is underway to define clinically meaningful HPV detection thresholds and to evaluate the potential clinical application of future generations of the PCR-MS assay. PMID:19410602

  16. Development and evaluation of a PCR and mass spectroscopy (PCR-MS)-based method for quantitative, type-specific detection of human papillomavirus.

    Science.gov (United States)

    Patel, Divya A; Shih, Yang-Jen; Newton, Duane W; Michael, Claire W; Oeth, Paul A; Kane, Michael D; Opipari, Anthony W; Ruffin, Mack T; Kalikin, Linda M; Kurnit, David M

    2009-09-01

    Knowledge of the central role of high-risk human papillomavirus (HPV) in cervical carcinogenesis, coupled with an emerging need to monitor the efficacy of newly introduced HPV vaccines, warrant development and evaluation of type-specific, quantitative HPV detection methods. In the present study, a prototype PCR and mass spectroscopy (PCR-MS)-based method to detect and quantitate 13 high-risk HPV types is compared to the Hybrid Capture 2 High-Risk HPV DNA test (HC2; Digene Corp., Gaithersburg, MD) in 199 cervical scraping samples and to DNA sequencing in 77 cervical tumor samples. High-risk HPV types were detected in 76/77 (98.7%) cervical tumor samples by PCR-MS. Degenerate and type-specific sequencing confirmed the types detected by PCR-MS. In 199 cervical scraping samples, all 13 HPV types were detected by PCR-MS. Eighteen (14.5%) of 124 cervical scraping samples that were positive for high-risk HPV by HC2 were negative by PCR-MS. In all these cases, degenerate DNA sequencing failed to detect any of the 13 high-risk HPV types. Nearly half (46.7%) of the 75 cervical scraping samples that were negative for high-risk HPV by the HC2 assay were positive by PCR-MS. Type-specific sequencing in a subset of these samples confirmed the HPV type detected by PCR-MS. Quantitative PCR-MS results demonstrated that 11/75 (14.7%) samples contained as much HPV copies/cell as HC2-positive samples. These findings suggest that this prototype PCR-MS assay performs at least as well as HC2 for HPV detection, while offering the additional, unique advantages of type-specific identification and quantitation. Further validation work is underway to define clinically meaningful HPV detection thresholds and to evaluate the potential clinical application of future generations of the PCR-MS assay.

  17. Human Milk Blocks DC-SIGN-Pathogen Interaction via MUC1

    NARCIS (Netherlands)

    Koning, Nathalie; Kessen, Sabine F M; Van Der Voorn, J Patrick; Appelmelk, Ben J; Jeurink, Prescilla V; Knippels, Leon M J; Garssen, Johan; Van Kooyk, Yvette

    2015-01-01

    Beneficial effects of breastfeeding are well-recognized and include both immediate neonatal protection against pathogens and long-term protection against allergies and autoimmune diseases. Although several proteins have been identified to have anti-viral or anti-bacterial effects like secretory IgA

  18. Detection of Specific Solvent Rearrangement Regions of an Enzyme: NMR and ITC Studies with Aminoglycoside Phosphotransferase(3 )-IIIa

    International Nuclear Information System (INIS)

    Ozen, C.; Norris, Adrianne; Land, Miriam Louise; Tjioe, Elina; Serpersu, Engin H

    2008-01-01

    This work describes differential effects of solvent in complexes of the aminoglycoside phosphotransferase(3 and cent;)-IIIa (APH) with different aminoglycosides and the detection of change in solvent structure at specific sites away from substrates. Binding of kanamycins to APH occurs with a larger negative and cent;H in H2O relative to D2O ( and cent; and cent;H(H2O-D2O) < 0), while the reverse is true for neomycins. Unusually large negative and cent;Cp values were observed for binding of aminoglycosides to APH. and cent;Cp for the APHneomycin complex was -1.6 kcal and acirc;mol-1 and acirc;deg-1. A break at 30 C was observed in the APH-kanamycin complex yielding and cent;Cp values of -0.7 kcal and acirc;mol-1 and acirc;deg-1 and -3.8 kcal and acirc;mol-1 and acirc;deg-1 below and above 30 C, respectively. Neither the change in accessible surface area ( and cent;ASA) nor contributions from heats of ionization were sufficient to explain the large negative and cent;Cp values. Most significantly, 15N-1H HSQC experiments showed that temperature-dependent shifts of the backbone amide protons of Leu 88, Ser 91, Cys 98, and Leu143 revealed a break at 30 C only in the APH-kanamycin complex in spectra collected between 21 C and 38 C. These amino acids represent solVent reorganization sites that experience a change in solvent structure in their immediate environment as structurally different ligands bind to the enzyme. These residues were away from the substrate binding site and distributed in three hydrophobic patches in APH. Overall, our results show that a large number of factors affect and cent;Cp and binding of structurally different ligand groups cause different solvent structure in the active site as well as differentially affecting specific sites away from the ligand binding site

  19. Indirect ELISA based on Hendra and Nipah virus proteins for the detection of henipavirus specific antibodies in pigs.

    Directory of Open Access Journals (Sweden)

    Kerstin Fischer

    Full Text Available Hendra virus (HeV and Nipah virus (NiV belong to the genus Henipavirus in the family Paramyxoviridae. Henipavirus infections were first reported in the 1990's causing severe and often fatal outbreaks in domestic animals and humans in Southeast Asia and Australia. NiV infections were observed in humans in Bangladesh, India and in the first outbreak in Malaysia, where pigs were also infected. HeV infections occurred in horses in the North-Eastern regions of Australia, with singular transmission events to humans. Bats of the genus Pteropus have been identified as the reservoir hosts for henipaviruses. Molecular and serological indications for the presence of henipa-like viruses in African fruit bats, pigs and humans have been published recently. In our study, truncated forms of HeV and NiV attachment (G proteins as well as the full-length NiV nucleocapsid (N protein were expressed using different expression systems. Based on these recombinant proteins, Enzyme-linked Immunosorbent Assays (ELISA were developed for the detection of HeV or NiV specific antibodies in porcine serum samples. We used the NiV N ELISA for initial serum screening considering the general reactivity against henipaviruses. The G protein based ELISAs enabled the differentiation between HeV and NiV infections, since as expected, the sera displayed higher reactivity with the respective homologous antigens. In the future, these assays will present valuable tools for serosurveillance of swine and possibly other livestock or wildlife species in affected areas. Such studies will help assessing the potential risk for human and animal health worldwide by elucidating the distribution of henipaviruses.

  20. Genet-specific DNA methylation probabilities detected in a spatial epigenetic analysis of a clonal plant population.

    Directory of Open Access Journals (Sweden)

    Kiwako S Araki

    Full Text Available In sessile organisms such as plants, spatial genetic structures of populations show long-lasting patterns. These structures have been analyzed across diverse taxa to understand the processes that determine the genetic makeup of organismal populations. For many sessile organisms that mainly propagate via clonal spread, epigenetic status can vary between clonal individuals in the absence of genetic changes. However, fewer previous studies have explored the epigenetic properties in comparison to the genetic properties of natural plant populations. Here, we report the simultaneous evaluation of the spatial structure of genetic and epigenetic variation in a natural population of the clonal plant Cardamine leucantha. We applied a hierarchical Bayesian model to evaluate the effects of membership of a genet (a group of individuals clonally derived from a single seed and vegetation cover on the epigenetic variation between ramets (clonal plants that are physiologically independent individuals. We sampled 332 ramets in a 20 m × 20 m study plot that contained 137 genets (identified using eight SSR markers. We detected epigenetic variation in DNA methylation at 24 methylation-sensitive amplified fragment length polymorphism (MS-AFLP loci. There were significant genet effects at all 24 MS-AFLP loci in the distribution of subepiloci. Vegetation cover had no statistically significant effect on variation in the majority of MS-AFLP loci. The spatial aggregation of epigenetic variation is therefore largely explained by the aggregation of ramets that belong to the same genets. By applying hierarchical Bayesian analyses, we successfully identified a number of genet-specific changes in epigenetic status within a natural plant population in a complex context, where genotypes and environmental factors are unevenly distributed. This finding suggests that it requires further studies on the spatial epigenetic structure of natural populations of diverse organisms

  1. Genet-specific DNA methylation probabilities detected in a spatial epigenetic analysis of a clonal plant population.

    Science.gov (United States)

    Araki, Kiwako S; Kubo, Takuya; Kudoh, Hiroshi

    2017-01-01

    In sessile organisms such as plants, spatial genetic structures of populations show long-lasting patterns. These structures have been analyzed across diverse taxa to understand the processes that determine the genetic makeup of organismal populations. For many sessile organisms that mainly propagate via clonal spread, epigenetic status can vary between clonal individuals in the absence of genetic changes. However, fewer previous studies have explored the epigenetic properties in comparison to the genetic properties of natural plant populations. Here, we report the simultaneous evaluation of the spatial structure of genetic and epigenetic variation in a natural population of the clonal plant Cardamine leucantha. We applied a hierarchical Bayesian model to evaluate the effects of membership of a genet (a group of individuals clonally derived from a single seed) and vegetation cover on the epigenetic variation between ramets (clonal plants that are physiologically independent individuals). We sampled 332 ramets in a 20 m × 20 m study plot that contained 137 genets (identified using eight SSR markers). We detected epigenetic variation in DNA methylation at 24 methylation-sensitive amplified fragment length polymorphism (MS-AFLP) loci. There were significant genet effects at all 24 MS-AFLP loci in the distribution of subepiloci. Vegetation cover had no statistically significant effect on variation in the majority of MS-AFLP loci. The spatial aggregation of epigenetic variation is therefore largely explained by the aggregation of ramets that belong to the same genets. By applying hierarchical Bayesian analyses, we successfully identified a number of genet-specific changes in epigenetic status within a natural plant population in a complex context, where genotypes and environmental factors are unevenly distributed. This finding suggests that it requires further studies on the spatial epigenetic structure of natural populations of diverse organisms, particularly for

  2. Potential of Diffusion Tensor Imaging and Relaxometry for the Detection of Specific Pathological Alterations in Parkinson's Disease (PD.

    Directory of Open Access Journals (Sweden)

    Regina Esterhammer

    Full Text Available The purpose of the present study was to evaluate the potential of multimodal MR imaging including mean diffusivity (MD, fractional anisotropy (FA, relaxation rates R2 and R2* to detect disease specific alterations in Parkinson's Disease (PD. We enrolled 82 PD patients (PD-all with varying disease durations (≤5 years: PD≤5, n = 43; >5 years: PD>5, n = 39 and 38 matched healthy controls (HC, receiving diffusion tensor imaging as well as R2 and R2* relaxometry calculated from multi-echo T2*-weighted and dual-echo TSE imaging, respectively. ROIs were drawn to delineate caudate nucleus (CN, putamen (PU, globus pallidus (GP and substantia nigra (SN on the co-registered maps. The SN was divided in 3 descending levels (SL 1-3. The most significant parameters were used for a flexible discrimination analysis (FDA in a training collective consisting of 25 randomized subjects from each group in order to predict the classification of remaining subjects. PD-all showed significant increases in MD, R2 and R2* within SN and its subregions as well as in MD and R2* within different basal ganglia regions. Compared to the HC group, the PD≤5 and the PD>5 group showed significant MD increases within the SN and its lower two subregions, while the PD≤5 group exhibited significant increases in R2 and R2* within SN and its subregions, and tended to elevation within the basal ganglia. The PD>5 group had significantly increased MD in PU and GP, whereas the PD≤5 group presented normal MD within the basal ganglia. FDA achieved right classification in 84% of study participants. Micro-structural damage affects primarily the SN of PD patients and in later disease stages the basal ganglia. Iron contents of PU, GP and SN are increased at early disease stages of PD.

  3. Source-specific sewage pollution detection in urban river waters using pharmaceuticals and personal care products as molecular indicators.

    Science.gov (United States)

    Kiguchi, Osamu; Sato, Go; Kobayashi, Takashi

    2016-11-01

    Source-specific elucidation of domestic sewage pollution caused by various effluent sources in an urban river water, as conducted for this study, demands knowledge of the relation between concentrations of pharmaceuticals and personal care products (PPCPs) as molecular indicators (caffeine, carbamazepine, triclosan) and water quality concentrations of total nitrogen (T-N) and total phosphorous (T-P). River water and wastewater samples from the Asahikawa River Basin in northern Japan were analyzed using derivatization-gas chromatography/mass spectrometry. Caffeine, used as an indicator of domestic sewage in the Asahikawa River Basin, was more ubiquitous than either carbamazepine or triclosan (92-100 %). Its concentration was higher than any target compound used to assess the basin: caffeine, caffeine concentrations detected in wastewater effluents and the strongly positive mutual linear correlation between caffeine and T-N or T-P (R 2  > 0.759) reflect the contribution of septic tank system effluents to the lower Asahikawa River Basin. Results of relative molecular indicators in combination with different molecular indicators (caffeine/carbamazepine and triclosan/carbamazepine) and cluster analysis better reflect the contribution of sewage than results obtained using concentrations of respective molecular indicators and cluster analysis. Relative molecular indicators used with water quality parameters (e.g., caffeine/T-N ratio) in this study provide results more clearly, relatively, and quantitatively than results obtained using molecular indicators alone. Moreover, the caffeine/T-N ratio reflects variations of caffeine flux from effluent sources. These results suggest strongly relative molecular indicators are also useful indicators, reflecting differences in spatial contributions of domestic sources for PPCPs in urban areas.

  4. Establishment of the cross-clade antigen detection system for H5 subtype influenza viruses using peptide monoclonal antibodies specific for influenza virus H5 hemagglutinin.

    Science.gov (United States)

    Takahashi, Hitoshi; Nagata, Shiho; Odagiri, Takato; Kageyama, Tsutomu

    2018-04-15

    The H5 subtype of highly pathogenic avian influenza (H5 HPAI) viruses is a threat to both animal and human public health and has the potential to cause a serious future pandemic in humans. Thus, specific and rapid detection of H5 HPAI viruses is required for infection control in humans. To develop a simple and rapid diagnostic system to detect H5 HPAI viruses with high specificity and sensitivity, we attempted to prepare monoclonal antibodies (mAbs) that specifically recognize linear epitopes in hemagglutinin (HA) of H5 subtype viruses. Nine mAb clones were obtained from mice immunized with a synthetic partial peptide of H5 HA molecules conserved among various H5 HPAI viruses. The antigen-capture enzyme-linked immunosorbent assay using the most suitable combination of these mAbs, which bound specifically to lysed H5 HA under an optimized detergent condition, was specific for H5 viruses and could broadly detect H5 viruses in multiple different clades. Taken together, these peptide mAbs, which recognize linear epitopes in a highly conserved region of H5 HA, may be useful for specific and highly sensitive detection of H5 HPAI viruses and can help in the rapid diagnosis of human, avian, and animal H5 virus infections. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Ex vivo detection of adenovirus specific CD4+ T-cell responses to HLA-DR-epitopes of the Hexon protein show a contracted specificity of THELPER cells following stem cell transplantation

    International Nuclear Information System (INIS)

    Serangeli, Celine; Bicanic, Oliver; Scheible, Michael H.; Wernet, Dorothee; Lang, Peter; Rammensee, Hans-Georg; Stevanovic, Stefan; Handgretinger, Rupert; Feuchtinger, Tobias

    2010-01-01

    Human adenovirus (HAdV) is a cause of significant morbidity and mortality in immunocompromised patients, especially after stem cell transplantation (SCT). Viral clearance has been attributed to CD4 + T-cell responses against the Hexon-protein, but the frequency of specific T HELPER cells is extremely low or not detectable ex vivo and preference for different CD4 + T-cell epitopes is variable among individuals. We therefore analyzed 44 healthy donors and 6 SCT-recipients for Hexon-specific CD4 + -responses ex vivo, to identify epitopes which would be broadly applicable. We selected 19 candidate epitopes with predicted restriction to HLA-DR1/DR3/DR4/DR7; 16 were located within the highly conserved regions, indicating cross-reactivity of T cells among HAdV-subspecies. Ten epitopes induced CD4 + -proliferation in >50% of individuals, confirmed by intracellular IFN-γ detection. Three SCT recipients who recovered from an infection with HAdV displayed reactivity towards only a single hexon epitope, whereas healthy individuals were responsive to two to eight epitopes (median 3). The ex vivo detection of Hexon-specific CD4 + T-cells, without any long-term culture in vitro, enables the detection and generation of HAdV-specific CD4 + T cells for adoptive T-cell transfer against HAdV-infection post SCT.

  6. Development of a loop-mediated isothermal amplification (LAMP) assay for rapid and specific detection of common genetically modified organisms (GMOs).

    Science.gov (United States)

    Feng, Jiawang; Tang, Shiming; Liu, Lideng; Kuang, Xiaoshan; Wang, Xiaoyu; Hu, Songnan; You, Shuzhu

    2015-03-01

    Here, we developed a loop-mediated isothermal amplification (LAMP) assay for 11 common transgenic target DNA in GMOs. Six sets of LAMP primer candidates for each target were designed and their specificity, sensitivity, and reproductivity were evaluated. With the optimized LAMP primers, this LAMP assay was simply run within 45-60 min to detect all these targets in GMOs tested. The sensitivity, specificity, and reproductivity of the LAMP assay were further analyzed in comparison with those of Real-Time PCR. In consistent with real-time PCR, detection of 0.5% GMOs in equivalent background DNA was possible using this LAMP assay for all targets. In comparison with real-time PCR, the LAMP assay showed the same results with simple instruments. Hence, the LAMP assay developed can provide a rapid and simple approach for routine screening as well as specific events detection of many GMOs.

  7. Toward optimizing patient-specific IMRT QA techniques in the accurate detection of dosimetrically acceptable and unacceptable patient plans.

    Science.gov (United States)

    McKenzie, Elizabeth M; Balter, Peter A; Stingo, Francesco C; Jones, Jimmy; Followill, David S; Kry, Stephen F

    2014-12-01

    in the performance of any device between gamma criteria of 2%/2 mm, 3%/3 mm, and 5%/3 mm. Finally, optimal cutoffs (e.g., percent of pixels passing gamma) were determined for each device and while clinical practice commonly uses a threshold of 90% of pixels passing for most cases, these results showed variability in the optimal cutoff among devices. IMRT QA devices have differences in their ability to accurately detect dosimetrically acceptable and unacceptable plans. Field-by-field analysis with a MapCheck device and use of the MapCheck with a MapPhan phantom while delivering at planned rotational gantry angles resulted in a significantly poorer ability to accurately sort acceptable and unacceptable plans compared with the other techniques examined. Patient-specific IMRT QA techniques in general should be thoroughly evaluated for their ability to correctly differentiate acceptable and unacceptable plans. Additionally, optimal agreement thresholds should be identified and used as common clinical thresholds typically worked very poorly to identify unacceptable plans.

  8. Comparison of Bovine coronavirus-specific and Bovine respiratory syncytial virus-specific antibodies in serum versus milk samples detected by enzyme-linked immunosorbent assay.

    Science.gov (United States)

    Ohlson, Anna; Blanco-Penedo, Isabel; Fall, Nils

    2014-01-01

    Bovine coronavirus (BCV; Betacoronavirus 1) and Bovine respiratory syncytial virus (BRSV) are significant causes of enteric and respiratory disease in beef and dairy cattle throughout the world. Indirect enzyme-linked immunosorbent assays are widely used to detect serum antibodies for herd monitoring and prevalence studies. In dairy herds, milk is more readily collected than serum. Hence, in order to investigate the test agreement between serum and milk, both serum and milk samples from 105 cows in 27 dairy herds were analyzed in parallel for presence of immunoglobulin G antibodies to BCV and BRSV. The Bland-Altman analyses of data demonstrated good agreement between serum and milk antibody titers for both viruses. The results indicate milk samples are sufficient for surveillance of antibodies to BCV and BRSV.

  9. The simultaneous ex vivo detection of low-frequency antigen-specific CD4+ and CD8+ T-cell responses using overlapping peptide pools.

    Science.gov (United States)

    Singh, Satwinder Kaur; Meyering, Maaike; Ramwadhdoebe, Tamara H; Stynenbosch, Linda F M; Redeker, Anke; Kuppen, Peter J K; Melief, Cornelis J M; Welters, Marij J P; van der Burg, Sjoerd H

    2012-11-01

    The ability to measure antigen-specific T cells at the single-cell level by intracellular cytokine staining (ICS) is a promising immunomonitoring tool and is extensively applied in the evaluation of immunotherapy of cancer. The protocols used to detect antigen-specific CD8+ T-cell responses generally work for the detection of antigen-specific T cells in samples that have undergone at least one round of in vitro pre-stimulation. Application of a common protocol but now using long peptides as antigens was not suitable to simultaneously detect antigen-specific CD8+ and CD4+ T cells directly ex vivo in cryopreserved samples. CD8 T-cell reactivity to monocytes pulsed with long peptides as antigens ranged between 5 and 25 % of that observed against monocytes pulsed with a direct HLA class I fitting minimal CTL peptide epitope. Therefore, we adapted our ICS protocol and show that the use of tenfold higher concentration of long peptides to load APC, the use of IFN-α and poly(I:C) to promote antigen processing and improve T-cell stimulation, does allow for the ex vivo detection of low-frequency antigen-specific CD8+ and CD4+ T cells in an HLA-independent setting. While most of the improvements were related to increasing the ability to measure CD8+ T-cell reactivity following stimulation with long peptides to at least 50 % of the response detected when using a minimal peptide epitope, the final analysis of blood samples from vaccinated patients successfully showed that the adapted ICS protocol also increases the ability to ex vivo detect low-frequency p53-specific CD4+ T-cell responses in cryopreserved PBMC samples.

  10. Design of a species-specific PCR method for the detection of the heat-resistant fungi Talaromyces macrosporus and Talaromyces trachyspermus.

    Science.gov (United States)

    Yamashita, S; Nakagawa, H; Sakaguchi, T; Arima, T-H; Kikoku, Y

    2018-01-01

    Heat-resistant fungi occur sporadically and are a continuing problem for the food and beverage industry. The genus Talaromyces, as a typical fungus, is capable of producing the heat-resistant ascospores responsible for the spoilage of processed food products. Isocitrate lyase, a signature enzyme of the glyoxylate cycle, is required for the metabolism of non-fermentable carbon compounds, like acetate and ethanol. Here, species-specific primer sets for detection and identification of DNA derived from Talaromyces macrosporus and Talaromyces trachyspermus were designed based on the nucleotide sequences of their isocitrate lyase genes. Polymerase chain reaction (PCR) using a species-specific primer set amplified products specific to T. macrosporus and T. trachyspermus. Other fungal species, such as Byssochlamys fulva and Hamigera striata, which cause food spoilage, were not detected using the Talaromyces-specific primer sets. The detection limit for each species-specific primer set was determined as being 50 pg of template DNA, without using a nested PCR method. The specificity of each species-specific primer set was maintained in the presence of 1,000-fold amounts of genomic DNA from other fungi. The method also detected fungal DNA extracted from blueberry inoculated with T. macrosporus. This PCR method provides a quick, simple, powerful and reliable way to detect T. macrosporus and T. trachyspermus. Polymerase chain reaction (PCR)-based detection is rapid, convenient and sensitive compared with traditional methods of detecting heat-resistant fungi. In this study, a PCR-based method was developed for the detection and identification of amplification products from Talaromyces macrosporus and Talaromyces trachyspermus using primer sets that target the isocitrate lyase gene. This method could be used for the on-site detection of T. macrosporus and T. trachyspermus in the near future, and will be helpful in the safety control of raw materials and in food and beverage

  11. A TaqMan-based real time PCR assay for specific detection and quantification of Xylella fastidiosa strains causing bacterial leaf scorch in oleander.

    Science.gov (United States)

    Guan, Wei; Shao, Jonathan; Singh, Raghuwinder; Davis, Robert E; Zhao, Tingchang; Huang, Qi

    2013-02-15

    A TaqMan-based real-time PCR assay was developed for specific detection of strains of X. fastidiosa causing oleander leaf scorch. The assay uses primers WG-OLS-F1 and WG-OLS-R1 and the fluorescent probe WG-OLS-P1, designed based on unique sequences found only in the genome of oleander strain Ann1. The assay is specific, allowing detection of only oleander-infecting strains, not other strains of X. fastidiosa nor other plant-associated bacteria tested. The assay is also sensitive, with a detection limit of 10.4fg DNA of X. fastidiosa per reaction in vitro and in planta. The assay can also be applied to detect low numbers of X. fastidiosa in insect samples, or further developed into a multiplex real-time PCR assay to simultaneously detect and distinguish diverse strains of X. fastidiosa that may occupy the same hosts or insect vectors. Specific and sensitive detection and quantification of oleander strains of X. fastidiosa should be useful for disease diagnosis, epidemiological studies, management of oleander leaf scorch disease, and resistance screening for oleander shrubs. Published by Elsevier B.V.

  12. Detection of glyco-mucin profiles improves specificity of MUC16 and MUC1 biomarkers in ovarian serous tumours

    DEFF Research Database (Denmark)

    Ricardo, Sara; da Silva, Lara Patricia Marcos; Pereira, Daniela

    2015-01-01

    The CA125 assay detects circulating MUC16 and is one of the most widely used cancer biomarkers for the follow-up of ovarian cancer. We previously demonstrated that detection of aberrant cancer-associated glycoforms of MUC16 as well as MUC1 in circulation could improve the yield of these serum ass...

  13. Evaluation of efficiency of nested multiplex allele-specific PCR assay for detection of multidrug resistant tuberculosis directly from sputum samples.

    Science.gov (United States)

    Mistri, S K; Sultana, M; Kamal, S M M; Alam, M M; Irin, F; Nessa, J; Ahsan, C R; Yasmin, M

    2016-05-01

    For an effective control of tuberculosis, rapid detection of multidrug resistant tuberculosis (MDR-TB) is necessary. Therefore, we developed a modified nested multiplex allele-specific polymerase chain reaction (MAS-PCR) method that enables rapid MDR-TB detection directly from sputum samples. The efficacy of this method was evaluated using 79 sputum samples collected from suspected tuberculosis patients. The performance of nested MAS-PCR method was compared with other MDR-TB detection methods like drug susceptibility testing (DST) and DNA sequencing. As rifampicin (RIF) resistance conforms to MDR-TB in greater than 90% cases, only the presence of RIF-associated mutations in rpoB gene was determined by DNA sequencing and nested MAS-PCR to detect MDR-TB. The concordance between nested MAS-PCR and DNA sequencing results was found to be 96·3%. When compared with DST, the sensitivity and specificity of nested MAS-PCR for RIF-resistance detection were determined to be 92·9 and 100% respectively. For developing- and high-TB burden countries, molecular-based tests have been recommended by the World Health Organization for rapid detection of MDR-TB. The results of this study indicate that, nested MAS-PCR assay might be a practical and relatively cost effective molecular method for rapid detection of MDR-TB from suspected sputum samples in developing countries with resource poor settings. © 2016 The Society for Applied Microbiology.

  14. PCR-Independent Detection of Bacterial Species-Specific 16S rRNA at 10 fM by a Pore-Blockage Sensor

    Directory of Open Access Journals (Sweden)

    Leyla Esfandiari

    2016-07-01

    Full Text Available A PCR-free, optics-free device is used for the detection of Escherichia coli (E. coli 16S rRNA at 10 fM, which corresponds to ~100–1000 colony forming units/mL (CFU/mL depending on cellular rRNA levels. The development of a rapid, sensitive, and cost-effective nucleic acid detection platform is sought for the detection of pathogenic microbes in food, water and body fluids. Since 16S rRNA sequences are species specific and are present at high copy number in viable cells, these nucleic acids offer an attractive target for microbial pathogen detection schemes. Here, target 16S rRNA of E. coli at 10 fM concentration was detected against a total RNA background using a conceptually simple approach based on electromechanical signal transduction, whereby a step change reduction in ionic current through a pore indicates blockage by an electrophoretically mobilized bead-peptide nucleic acid probe conjugate hybridized to target nucleic acid. We investigated the concentration detection limit for bacterial species-specific 16S rRNA at 1 pM to 1 fM and found a limit of detection of 10 fM for our device, which is consistent with our previous finding with single-stranded DNA of similar length. In addition, no false positive responses were obtained with control RNA and no false negatives with target 16S rRNA present down to the limit of detection (LOD of 10 fM. Thus, this detection scheme shows promise for integration into portable, low-cost systems for rapid detection of pathogenic microbes in food, water and body fluids.

  15. Rapid detection of methicillin resistance in coagulase-negative staphylococci by a penicillin-binding protein 2a-specific latex agglutination test.

    Science.gov (United States)

    Horstkotte, M A; Knobloch, J K; Rohde, H; Mack, D

    2001-10-01

    The detection of PBP 2a by the MRSA-Screen latex agglutination test with 201 clinical coagulase-negative staphylococci had an initial sensitivity of 98% and a high degree of specificity for Staphylococcus epidermidis strains compared to PCR for mecA. Determination of oxacillin MICs evaluated according to the new breakpoint (0.5 microg/ml) of the National Committee for Clinical Laboratory Standards exhibited an extremely low specificity for this population.

  16. Rapid Detection of Methicillin Resistance in Coagulase-Negative Staphylococci by a Penicillin-Binding Protein 2a-Specific Latex Agglutination Test

    OpenAIRE

    Horstkotte, Matthias A.; Knobloch, Johannes K.-M.; Rohde, Holger; Mack, Dietrich

    2001-01-01

    The detection of PBP 2a by the MRSA-Screen latex agglutination test with 201 clinical coagulase-negative staphylococci had an initial sensitivity of 98% and a high degree of specificity for Staphylococcus epidermidis strains compared to PCR for mecA. Determination of oxacillin MICs evaluated according to the new breakpoint (0.5 μg/ml) of the National Committee for Clinical Laboratory Standards exhibited an extremely low specificity for this population.

  17. LAMP-based group specific detection of aflatoxin producers within Aspergillus section Flavi in food raw materials, spices, and dried fruit using neutral red for visible-light signal detection.

    Science.gov (United States)

    Niessen, Ludwig; Bechtner, Julia; Fodil, Sihem; Taniwaki, Marta H; Vogel, Rudi F

    2018-02-02

    Aflatoxins can be produced by 21 species within sections Flavi (16 species), Ochraceorosei (2), and Nidulantes (3) of the fungal genus Aspergillus. They pose risks to human and animal health due to high toxicity and carcinogenicity. Detecting aflatoxin producers can help to assess toxicological risks associated with contaminated commodities. Species specific molecular assays (PCR and LAMP) are available for detection of major producers, but fail to detect species of minor importance. To enable rapid and sensitive detection of several aflatoxin producing species in a single analysis, a nor1 gene-specific LAMP assay was developed. Specificity testing showed that among 128 fungal species from 28 genera, 15 aflatoxigenic species in section Flavi were detected, including synonyms of A. flavus and A. parasiticus. No cross reactions were found with other tested species. The detection limit of the assay was 9.03pg of A. parasiticus genomic DNA per reaction. Visual detection of positive LAMP reactions under daylight conditions was facilitated using neutral red to allow unambiguous distinction between positive and negative assay results. Application of the assay to the detection of A. parasiticus conidia revealed a detection limit of 211 conidia per reaction after minimal sample preparation. The usefulness of the assay was demonstrated in the analysis of aflatoxinogenic species in samples of rice, nuts, raisins, dried figs, as well as powdered spices. Comparison of LAMP results with presence/absence of aflatoxins and aflatoxin producing fungi in 50 rice samples showed good correlation between these parameters. Our study suggests that the developed LAMP assay is a rapid, sensitive and user-friendly tool for surveillance and quality control in our food industry. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Development of a multiplex assay for genus- and species-specific detection of Phytophthora based on differences in mitochondrial gene order.

    Science.gov (United States)

    Bilodeau, Guillaume J; Martin, Frank N; Coffey, Michael D; Blomquist, Cheryl L

    2014-07-01

    A molecular diagnostic assay for Phytophthora spp. that is specific, sensitive, has both genus- and species-specific detection capabilities multiplexed, and can be used to systematically develop markers for detection of a wide range of species would facilitate research and regulatory efforts. To address this need, a marker system was developed based on the high copy sequences of the mitochondrial DNA utilizing gene orders that were highly conserved in the genus Phytophthora but different in the related genus Pythium and plants to reduce the importance of highly controlled annealing temperatures for specificity. An amplification primer pair designed from conserved regions of the atp9 and nad9 genes produced an amplicon of ≈340 bp specific for the Phytophthora spp. tested. The TaqMan probe for the genus-specific Phytophthora test was designed from a conserved portion of the atp9 gene whereas variable intergenic spacer sequences were used for designing the species-specific TaqMan probes. Specific probes were developed for 13 species and the P. citricola species complex. In silico analysis suggests that species-specific probes could be developed for at least 70 additional described and provisional species; the use of locked nucleic acids in TaqMan probes should expand this list. A second locus spanning three tRNAs (trnM-trnP-trnM) was also evaluated for genus-specific detection capabilities. At 206 bp, it was not as useful for systematic development of a broad range of species-specific probes as the larger 340-bp amplicon. All markers were validated against a test panel that included 87 Phytophthora spp., 14 provisional Phytophthora spp., 29 Pythium spp., 1 Phytopythium sp., and 39 plant species. Species-specific probes were validated further against a range of geographically diverse isolates to ensure uniformity of detection at an intraspecific level, as well as with other species having high levels of sequence similarity to ensure specificity. Both diagnostic

  19. Validation of a commercial ELISA for the detection of bluetongue virus (BTV) specific antibodies in individual milk samples of Dutch dairy cows

    NARCIS (Netherlands)

    Kramps, J.A.; Maanen, van K.; Mars, M.H.; Popma, J.K.; Rijn, van P.A.

    2008-01-01

    recently developed indirect ELISA for the detection of bluetongue virus (BTV)-specific antibodies in bovine milk samples was compared to that of the routinely used competitive ELISA on serum samples. During the bluetongue outbreak in the Netherlands in 2006, caused by BTV serotype 8, coupled serum

  20. Optomagnetic Detection of MicroRNA Based on Duplex-Specific Nuclease-Assisted Target Recycling and Multilayer Core-Satellite Magnetic Superstructures

    DEFF Research Database (Denmark)

    Tian, Bo; Ma, Jing; Qiu, Zhen

    2017-01-01

    -efficiency, and potential for bioresponsive multiplexing. Herein, we demonstrate a sensitive and rapid miRNA detection method based on optomagnetic read-out, duplex-specific nuclease (DSN)-assisted target recycling, and the use of multilayer core-satellite magnetic superstructures. Triggered by the presence of target mi...

  1. Development of SCAR markers and PCR assays for single or simultaneous species-specific detection of Phytophthora nicotianae and Pythium helicoides in ebb-and-flow irrigated kalanchoe.

    Science.gov (United States)

    Ahonsi, Monday O; Ling, Yin; Kageyama, Koji

    2010-11-01

    Phytophthora nicotianae and Pythium helicoides are important water-borne oomycete pathogens of irrigated ornamentals particularly ebb-and-flow irrigated kalanchoe in Japan. We developed novel PCR-based sequence characterized amplified region markers and assays for rapid identification and species-specific detection of both pathogens in separate PCR reactions or simultaneously in a duplex PCR.

  2. An accurate, specific, sensitive, high-throughput method based on a microsphere immunoassay for multiplex detection of three viruses and bacterial fruit blotch bacterium in cucurbits.

    Science.gov (United States)

    Charlermroj, Ratthaphol; Makornwattana, Manlika; Himananto, Orawan; Seepiban, Channarong; Phuengwas, Sudtida; Warin, Nuchnard; Gajanandana, Oraprapai; Karoonuthaisiri, Nitsara

    2017-09-01

    To employ a microsphere immunoassay (MIA) to simultaneously detect multiple plant pathogens (potyviruses, Watermelon silver mottle virus, Melon yellow spot virus, and Acidovorax avenae subsp. citrulli) in actual plant samples, several factors need to be optimized and rigorously validated. Here, a simple extraction method using a single extraction buffer was successfully selected to detect the four pathogens in various cucurbit samples (cucumber, cantaloupe, melon, and watermelon). The extraction method and assay performance were validated with inoculated and field cucurbit samples. The MIA showed 98-99% relative accuracy, 97-100% relative specificity and 92-100% relative sensitivity when compared to commercial ELISA kits and reverse transcription PCR. In addition, the MIA was also able to accurately detect multiple-infected field samples. The results demonstrate that one common extraction method for all tested cucurbit samples could be applied to detect multiple pathogens; avoiding the need for multiple protocols to be employed. This multiplex method can therefore be instrumental for high-throughput screening of multiple plant pathogens with many advantages such as a shorter assay time (2.5h) with single assay format, a lower cost of detection ($5 vs $19.7 for 4 pathogens/sample) and less labor requirement. Its multiplex capacity can also be expanded to detect up to 50 different pathogens upon the availability of specific antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Carbapenem inactivation: a very affordable and highly specific method for phenotypic detection of carbapenemase-producing Pseudomonas aeruginosa isolates compared with other methods.

    Science.gov (United States)

    Akhi, Mohammad Taghi; Khalili, Younes; Ghotaslou, Reza; Kafil, Hossein Samadi; Yousefi, Saber; Nagili, Behroz; Goli, Hamid Reza

    2017-06-01

    This investigation was undertaken to compare phenotypic and molecular methods for detection of carbapenemase-producing Pseudomonas aeruginosa. A total of 245 non-duplicated isolates of P. aeruginosa were collected from hospitalized patients. Disc diffusion method was used to identify carbapenem-resistant bacteria. Three phenotypic methods, including Modified Hodge Test (MHT), Modified Carba NP (MCNP) test and Carbapenem Inactivation Method (CIM) were used for investigation of carbapenemase production. In addition, polymerase chain reaction (PCR) was used to detect carbapenemase encoding genes. Of 245 P. aeruginosa isolates investigated, 121 isolates were carbapenem-resistant. Among carbapenem-resistant isolates, 40, 39 and 35 isolates exhibited positive results using MHT, MCNP test and CIM, respectively. PCR indicated the presence of carbapenemase genes in 35 of carbapenem-resistant isolates. MHT showed low sensitivity and specificity for carbapenemase detection among P. aeruginosa isolates in comparison to PCR. CIM was most affordable and highly specific than MCNP test compared with the molecular method.

  4. Development and evaluation of tailored specific real-time RT-PCR assays for detection of foot-and-mouth disease virus serotypes circulating in East Africa

    DEFF Research Database (Denmark)

    Bachanek-Bankowska, Katarzyna; Mero, Herieth R.; Wadsworth, Jemma

    2016-01-01

    Rapid, reliable and accurate diagnostic methods provide essential support to programmes that monitor and control foot-and-mouth disease (FMD). While pan-specific molecular tests for FMD virus (FMDV) detection are well established and widely used in endemic and FMD-free countries, current serotyping...... methods mainly rely either on antigen detection ELISAs or nucleotide sequencing approaches. This report describes the development of a panel of serotype-specific real-time RT-PCR assays (rRT-PCR) tailored to detect FMDV lineages currently circulating in East Africa. These assays target sequences within...... sequencing. Samples (n = 71) representing serotype A (topotype AFRICA, lineage G-I), serotype O (topotypes EA-2 and EA-4), serotype SAT 1 (topotype I (NWZ)) and serotype SAT2 (topotype IV) were correctly identified with these rRT-PCR assays. Furthermore, FMDV RNA from samples that did not contain infectious...

  5. Identification of threshold prostate specific antigen levels to optimize the detection of clinically significant prostate cancer by magnetic resonance imaging/ultrasound fusion guided biopsy.

    Science.gov (United States)

    Shakir, Nabeel A; George, Arvin K; Siddiqui, M Minhaj; Rothwax, Jason T; Rais-Bahrami, Soroush; Stamatakis, Lambros; Su, Daniel; Okoro, Chinonyerem; Raskolnikov, Dima; Walton-Diaz, Annerleim; Simon, Richard; Turkbey, Baris; Choyke, Peter L; Merino, Maria J; Wood, Bradford J; Pinto, Peter A

    2014-12-01

    Prostate specific antigen sensitivity increases with lower threshold values but with a corresponding decrease in specificity. Magnetic resonance imaging/ultrasound targeted biopsy detects prostate cancer more efficiently and of higher grade than standard 12-core transrectal ultrasound biopsy but the optimal population for its use is not well defined. We evaluated the performance of magnetic resonance imaging/ultrasound targeted biopsy vs 12-core biopsy across a prostate specific antigen continuum. We reviewed the records of all patients enrolled in a prospective trial who underwent 12-core transrectal ultrasound and magnetic resonance imaging/ultrasound targeted biopsies from August 2007 through February 2014. Patients were stratified by each of 4 prostate specific antigen cutoffs. The greatest Gleason score using either biopsy method was compared in and across groups as well as across the population prostate specific antigen range. Clinically significant prostate cancer was defined as Gleason 7 (4 + 3) or greater. Univariate and multivariate analyses were performed. A total of 1,003 targeted and 12-core transrectal ultrasound biopsies were performed, of which 564 diagnosed prostate cancer for a 56.2% detection rate. Targeted biopsy led to significantly more upgrading to clinically significant disease compared to 12-core biopsy. This trend increased more with increasing prostate specific antigen, specifically in patients with prostate specific antigen 4 to 10 and greater than 10 ng/ml. Prostate specific antigen 5.2 ng/ml or greater captured 90% of upgrading by targeted biopsy, corresponding to 64% of patients who underwent multiparametric magnetic resonance imaging and subsequent fusion biopsy. Conversely a greater proportion of clinically insignificant disease was detected by 12-core vs targeted biopsy overall. These differences persisted when controlling for potential confounders on multivariate analysis. Prostate cancer upgrading with targeted biopsy increases

  6. Development of loop-mediated isothermal amplification assay for specific and rapid detection of differential goat pox virus and sheep pox virus.

    Science.gov (United States)

    Zhao, Zhixun; Fan, Bin; Wu, Guohua; Yan, Xinmin; Li, Yingguo; Zhou, Xiaoli; Yue, Hua; Dai, Xueling; Zhu, Haixia; Tian, Bo; Li, Jian; Zhang, Qiang

    2014-01-17

    Capripox viruses are economically important pathogens in goat and sheep producing areas of the world, with specific focus on goat pox virus (GTPV), sheep pox virus (SPPV) and the Lumpy Skin Disease virus (LSDV). Clinically, sheep pox and goat pox have the same symptoms and cannot be distinguished serologically. This presents a real need for a rapid, inexpensive, and easy to operate and maintain genotyping tool to facilitate accurate disease diagnosis and surveillance for better management of Capripox outbreaks. A LAMP method was developed for the specific differential detection of GTPV and SPPV using three sets of LAMP primers designed on the basis of ITR sequences. Reactions were performed at 62°C for either 45 or 60 min, and specificity confirmed by successful differential detection of several GTPV and SPPV isolates. No cross reactivity with Orf virus, foot-and-mouth disease virus (FMDV), A. marginale Lushi isolate, Mycoplasma mycoides subsp. capri, Chlamydophila psittaci, Theileria ovis, T. luwenshuni, T. uilenbergi or Babesia sp was noted. RFLP-PCR analysis of 135 preserved epidemic materials revealed 48 samples infected with goat pox and 87 infected with sheep pox, with LAMP test results showing a positive detection for all samples. When utilizing GTPV and SPPV genomic DNA, the universal LAMP primers (GSPV) and GTPV LAMP primers displayed a 100% detection rate; while the SPPV LAMP detection rate was 98.8%, consistent with the laboratory tested results. In summary, the three sets of LAMP primers when combined provide an analytically robust method able to fully distinguish between GTPV and SPPV. The presented LAMP method provides a specific, sensitive and rapid diagnostic tool for the distinction of GTPV and SPPV infections, with the potential to be standardized as a detection method for Capripox viruses in endemic areas.

  7. Detection of hepatic VX2 tumors in rabbits: comparison of conventional US and phase- inversion harmonic US during the liver- specific late phase of contrast enhancement

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Youk, Ji Hyun; Lee, Young Hwan; Kim, Young Kon; Kim, Chong Soo; Li, Chun Ai

    2003-01-01

    To compare phase-inversion sonography during the liver-specific phase of contrast enhancement using a microbubble contrast agent with conventional B-mode sonography for the detection of VX2 liver tumors. Twenty-three rabbits, 18 of which had VX2 liver tumor implants, received a bolus injection of 0.6 g of Levovist (200 mg/ml). During the liver-specific phase of this agent, they were evaluated using both conventional sonography and contrast-enhanced phase-inversion harmonic imaging (CEPIHI). Following sacrifice of the animals, pathologic analysis was performed and the reference standard thus obtained. The conspicuity, size and number of the tumors before and after contrast administration, as determined by a sonographer, were compared between the two modes and with the pathologic findings. CE-PIHI demonstrated marked hepatic parenchymal enhancement in all rabbits. For VX2 tumors detected at both conventional US and CE- PIHI, conspicuity was improved by contrast-enhanced PIHI. On examination of gross specimens, 52 VX2 tumors were identified. Conventional US correctly detected 18 of the 52 (34.6%), while PIHI detected 35 (67.3%) (p < 0.05). In particular, conventional US detected only three (8.3%) of the 36 tumors less than 10 mm in diameter, but CE-PIHI detected 19 such tumors (52.8%) (p < 0.05). Compared to conventional sonography, PIHI performed during the liver-specific phase after intravenous injection of Levovist is markedly better at detecting VX2 liver tumors

  8. 68Ga-PSMA PET/CT in Patients with Rising Prostatic-Specific Antigen After Definitive Treatment of Prostate Cancer: Detection Efficacy and Diagnostic accuracy.

    Science.gov (United States)

    Hamed, Maged Abdel Galil; Basha, Mohammad Abd Alkhalik; Ahmed, Hussien; Obaya, Ahmed Ali; Afifi, Amira Hamed Mohamed; Abdelbary, Eman H

    2018-06-20

    68 Ga-prostate-specific membrane antigen-11 ( 68 Ga-PSMA-11) is a recently developed positron emission tomography (PET) tracer that can detect prostate cancer (PC) relapses and metastases with high contrast resolution. The aim of this study was to assess the detection efficacy and diagnostic accuracy of 68 Ga-PSMA PET/CT image in patients with rising prostatic-specific antigen (PSA) after treatment of PC. The present prospective study included 188 patients who exhibited rising of PSA level on a routine follow-up examination after definitive treatment of PC. All patients underwent a 68 Ga-PSMA PET/CT examination. For each patient, we determined the disease stage, the Gleason score, and the maximum standardized uptake value of the local recurrence and extraprostatic metastases. The detection efficacy and diagnostic accuracy of 68 Ga-PSMA PET/CT were established by histopathology and clinical and imaging follow-up as the reference standards. 68 Ga-PSMA PET/CT detected tumour relapse in 165 patients (35 patients had local recurrence, 106 patients had extraprostatic metastases, and 24 patients had combined lesions). The sensitivity, specificity, and accuracy values of 68 Ga-PSMA PET/CT examination in the detection of PC recurrence were 98.8%, 100%, and 98.8%, respectively. 68 Ga-PSMA PET/CT revealed an overall detection rate of 87.8% (165/188) in patients with rising PSA (median of 2.2 ng/mL, and range of 0.01-70 ng/mL). 68 Ga-PSMA PET/CT is a valuable tool for the detection of PC local recurrence or extraprostatic metastases following rising PSA levels after primary definitive therapy and should be incorporated during routine work-up. Copyright © 2018. Published by Elsevier Inc.

  9. Cell-specific detection of microRNA expression during cardiomyogenesis by combined in situ hybridization and immunohistochemistry

    DEFF Research Database (Denmark)

    Schneider, Mikael; Andersen, Ditte Caroline; Silahtaroglu, Asli

    2011-01-01

    in connective tissue cells of the heart. More specifically, by co-staining with a-smooth muscle actin (a-SMA) and collagen-I, we found that miR-125b and -199a localize to perivascular a-SMA(-) stromal cells. Our approach thus proved valid for determining cell-specific localization of miRNAs, and the findings we...

  10. Development and evaluation of tailored specific real-time RT-PCR assays for detection of foot-and-mouth disease virus serotypes circulating in East Africa.

    Science.gov (United States)

    Bachanek-Bankowska, Katarzyna; Mero, Herieth R; Wadsworth, Jemma; Mioulet, Valerie; Sallu, Raphael; Belsham, Graham J; Kasanga, Christopher J; Knowles, Nick J; King, Donald P

    2016-11-01

    Rapid, reliable and accurate diagnostic methods provide essential support to programmes that monitor and control foot-and-mouth disease (FMD). While pan-specific molecular tests for FMD virus (FMDV) detection are well established and widely used in endemic and FMD-free countries, current serotyping methods mainly rely either on antigen detection ELISAs or nucleotide sequencing approaches. This report describes the development of a panel of serotype-specific real-time RT-PCR assays (rRT-PCR) tailored to detect FMDV lineages currently circulating in East Africa. These assays target sequences within the VP1-coding region that share high intra-lineage identity, but do not cross-react with FMD viruses from other serotypes that circulate in the region. These serotype-specific assays operate with the same thermal profile as the pan-diagnostic tests making it possible to run them in parallel to produce C T values comparable to the pan-diagnostic test detecting the 3D-coding region. These assays were evaluated alongside the established pan-specific molecular test using field samples and virus isolates collected from Tanzania, Kenya and Ethiopia that had been previously characterised by nucleotide sequencing. Samples (n=71) representing serotype A (topotype AFRICA, lineage G-I), serotype O (topotypes EA-2 and EA-4), serotype SAT 1 (topotype I (NWZ)) and serotype SAT2 (topotype IV) were correctly identified with these rRT-PCR assays. Furthermore, FMDV RNA from samples that did not contain infectious virus could still be serotyped using these assays. These serotype-specific real-time RT-PCR assays can detect and characterise FMDVs currently circulating in East Africa and hence improve disease control in this region. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  11. Development and use of fluorescent 16S rRNA-targeted probes for the specific detection of Methylophaga species by in situ hybridization in marine sediments.

    Science.gov (United States)

    Janvier, Monique; Regnault, Béatrice; Grimont, Patrick

    2003-09-01

    Methylotrophic bacteria are widespread in nature. They may play an important role in the cycling of carbon and in the metabolism of dimethylsulfide in a marine environment. Bacteria belonging to the genus Methylophaga are a unique group of aerobic, halophilic, non-methane-utilizing methylotrophs. Two 16S rRNA-targeted oligonucleotide probes were developed for the specific detection of Methylophaga species, marine methylobacteria, by fluorescence in situ hybridization. Probe MPH-730 was highly specific for all members of the genus Methylophaga while probe MPHm-994 targeted exclusively M. marina. The application of these probes were demonstrated by the detection of Methylophaga species in enrichment cultures from various marine sediments. All isolates recovered were visualized by using the genus specific probe MPH-730. The results were confirmed by 16S rDNA sequencing which demonstrated that all selected isolates belong to Methylophaga. Five isolates could be detected by the M. marina-specific probe MPHm-994 and were confirmed by rRNA gene restriction pattern (ribotyping). With the development of these specific probes, fluorescence in situ hybridization shows that the genus Methylophaga is widespread in marine samples.

  12. A novel dendritic cell-based direct ex vivo assay for detection and enumeration of circulating antigen-specific human T cells.

    Science.gov (United States)

    Carrio, Roberto; Zhang, Ge; Drake, Donald R; Schanen, Brian C

    2018-05-07

    Although a variety of assays have been used to examine T cell responses in vitro, standardized ex vivo detection of antigen-specific CD4 + T cells from human circulatory PBMCs remains constrained by low-dimensional characterization outputs and the need for polyclonal, mitogen-induced expansion methods to generate detectable response signals. To overcome these limitations, we developed a novel methodology utilizing antigen-pulsed autologous human dendritic target cells in a rapid and sensitive assay to accurately enumerate antigen-specific CD4 + T cell precursor frequency by multiparametric flow cytometry. With this approach, we demonstrate the ability to reproducibly quantitate poly-functional T cell responses following both primary and recall antigenic stimulation. Furthermore, this approach enables more comprehensive phenotypic profiling of circulating antigen-specific CD4 + T cells, providing valuable insights into the pre-existing polarization of antigen-specific T cells in humans. Combined, this approach permits sensitive and detailed ex vivo detection of antigen-specific CD4 + T cells delivering an important tool for advancing vaccine, immune-oncology and other therapeutic studies.

  13. Sensitivitas dan Spesifisitas Nested Polymerase Chain Reaction untuk Mendeteksi DNA Coxiella burnetii (SENSITIVITY AND SPECIFICITY OF NESTED POLYMERASE CHAIN REACTION FOR DETECTION OF COXIELLA BURNETII DNA

    Directory of Open Access Journals (Sweden)

    Trioso Purnawarman

    2014-04-01

    Full Text Available Sensitivity and specificity of nested polymerase chain reaction (nested PCR to detect Coxiella burnetii(C. burnetii DNA were studied. The primer system which consists of external primers (OMP1 and OMP2and internal primers (OMP3 and OMP4, was designed from the nucleotide sequence of the com I geneencoding for 27 kDa outer membrane protein and used to specifically amplify a 501 bp and 438 bp fragment.This nested PCR assay was 50 fold more sensitive than that of using PCR external primer only. TheNested PCR has a detection limit as low as 300 pg/?l. Specificity studies showed that nested PCR onlydetected C. burnetii DNA and did not happened Brucella abortus, Escherichia coli, Pseudomonas aeruginosaand Campylobacter Jejuni DNA. Nested PCR has high senstively and specificaly diagnostic method of C.burnetii as agent of Q fever disease.

  14. Specific Detection and Identification of American Mulberry-Infecting and Italian Olive-Associated Strains of Xylella fastidiosa by Polymerase Chain Reaction.

    Directory of Open Access Journals (Sweden)

    Wei Guan

    Full Text Available Xylella fastidiosa causes bacterial leaf scorch in many landscape trees including elm, oak, sycamore and mulberry, but methods for specific identification of a particular tree host species-limited strain or differentiation of tree-specific strains are lacking. It is also unknown whether a particular landscape tree-infecting X. fastidiosa strain is capable of infecting multiple landscape tree species in an urban environment. We developed two PCR primers specific for mulberry-infecting strains of X. fastidiosa based on the nucleotide sequence of a unique open reading frame identified only in mulberry-infecting strains among all the North and South American strains of X. fastidiosa sequenced to date. PCR using the primers allowed for detection and identification of mulberry-infecting X. fastidiosa strains in cultures and in samples collected from naturally infected mulberry trees. In addition, no mixed infections with or non-specific detections of the mulberry-infecting strains of X. fastidiosa were found in naturally X. fastidiosa-infected oak, elm and sycamore trees growing in the same region where naturally infected mulberry trees were grown. This genotype-specific PCR assay will be valuable for disease diagnosis, studies of strain-specific infections in insects and plant hosts, and management of diseases caused by X. fastidiosa. Unexpectedly but interestingly, the unique open reading frame conserved in the mulberry-infecting strains in the U. S. was also identified in the recently sequenced olive-associated strain CoDiRO isolated in Italy. When the primer set was tested against naturally infected olive plant samples collected in Italy, it allowed for detection of olive-associated strains of X. fastidiosa in Italy. This PCR assay, therefore, will also be useful for detection and identification of the Italian group of X. fastidiosa strains to aid understanding of the occurrence, evolution and biology of this new group of X. fastidiosa strains.

  15. Specific Detection and Identification of American Mulberry-Infecting and Italian Olive-Associated Strains of Xylella fastidiosa by Polymerase Chain Reaction.

    Science.gov (United States)

    Guan, Wei; Shao, Jonathan; Elbeaino, Toufic; Davis, Robert E; Zhao, Tingchang; Huang, Qi

    2015-01-01

    Xylella fastidiosa causes bacterial leaf scorch in many landscape trees including elm, oak, sycamore and mulberry, but methods for specific identification of a particular tree host species-limited strain or differentiation of tree-specific strains are lacking. It is also unknown whether a particular landscape tree-infecting X. fastidiosa strain is capable of infecting multiple landscape tree species in an urban environment. We developed two PCR primers specific for mulberry-infecting strains of X. fastidiosa based on the nucleotide sequence of a unique open reading frame identified only in mulberry-infecting strains among all the North and South American strains of X. fastidiosa sequenced to date. PCR using the primers allowed for detection and identification of mulberry-infecting X. fastidiosa strains in cultures and in samples collected from naturally infected mulberry trees. In addition, no mixed infections with or non-specific detections of the mulberry-infecting strains of X. fastidiosa were found in naturally X. fastidiosa-infected oak, elm and sycamore trees growing in the same region where naturally infected mulberry trees were grown. This genotype-specific PCR assay will be valuable for disease diagnosis, studies of strain-specific infections in insects and plant hosts, and management of diseases caused by X. fastidiosa. Unexpectedly but interestingly, the unique open reading frame conserved in the mulberry-infecting strains in the U. S. was also identified in the recently sequenced olive-associated strain CoDiRO isolated in Italy. When the primer set was tested against naturally infected olive plant samples collected in Italy, it allowed for detection of olive-associated strains of X. fastidiosa in Italy. This PCR assay, therefore, will also be useful for detection and identification of the Italian group of X. fastidiosa strains to aid understanding of the occurrence, evolution and biology of this new group of X. fastidiosa strains.

  16. HIV-1 specific IgA detected in vaginal secretions of HIV uninfected women participating in a microbicide trial in Southern Africa are primarily directed toward gp120 and gp140 specificities.

    Directory of Open Access Journals (Sweden)

    Kelly E Seaton

    Full Text Available Many participants in microbicide trials remain uninfected despite ongoing exposure to HIV-1. Determining the emergence and nature of mucosal HIV-specific immune responses in such women is important, since these responses may contribute to protection and could provide insight for the rational design of HIV-1 vaccines.We first conducted a pilot study to compare three sampling devices (Dacron swabs, flocked nylon swabs and Merocel sponges for detection of HIV-1-specific IgG and IgA antibodies in vaginal secretions. IgG antibodies from HIV-1-positive women reacted broadly across the full panel of eight HIV-1 envelope (Env antigens tested, whereas IgA antibodies only reacted to the gp41 subunit. No Env-reactive antibodies were detected in the HIV-negative women. The three sampling devices yielded equal HIV-1-specific antibody titers, as well as total IgG and IgA concentrations. We then tested vaginal Dacron swabs archived from 57 HIV seronegative women who participated in a microbicide efficacy trial in Southern Africa (HPTN 035. We detected vaginal IgA antibodies directed at HIV-1 Env gp120/gp140 in six of these women, and at gp41 in another three women, but did not detect Env-specific IgG antibodies in any women.Vaginal secretions of HIV-1 infected women contained IgG reactivity to a broad range of Env antigens and IgA reactivity to gp41. In contrast, Env-binding antibodies in the vaginal secretions of HIV-1 uninfected women participating in the microbicide trial were restricted to the IgA subtype and were mostly directed at HIV-1 gp120/gp140.

  17. A Novel, Rapid Assay for Detection and Differentiation of Serotype-Specific Antibodies to Venezuelan Equine Encephalitis Complex Alphaviruses

    National Research Council Canada - National Science Library

    Wang, Eryu; Paessler, Slobodan; Smith, Darci R; Coffey, Lark L; Kang, Wenli; Estrada-Franco, Jose; Weaver, Scott C; Aguilar, Patricia V; Pfeffer, Martin; Olson, James

    2005-01-01

    ... of Venezuelan equine encephalitis (VEE) virus. Two monoclonal antibodies that differentially recognize epizootic versus enzootic VEE virus epitopes were used to measure the serotype-specific blocking abilities of antibodies in sera of naturally...

  18. Event-specific qualitative and quantitative PCR detection of the GMO carnation (Dianthus caryophyllus) variety Moonlite based upon the 5'-transgene integration sequence.

    Science.gov (United States)

    Li, P; Jia, J W; Jiang, L X; Zhu, H; Bai, L; Wang, J B; Tang, X M; Pan, A H

    2012-04-27

    To ensure the implementation of genetically modified organism (GMO)-labeling regulations, an event-specific detection method was developed based on the junction sequence of an exogenous integrant in the transgenic carnation variety Moonlite. The 5'-transgene integration sequence was isolated by thermal asymmetric interlaced PCR. Based upon the 5'-transgene integration sequence, the event-specific primers and TaqMan probe were designed to amplify the fragments, which spanned the exogenous DNA and carnation genomic DNA. Qualitative and quantitative PCR assays were developed employing the designed primers and probe. The detection limit of the qualitative PCR assay was 0.05% for Moonlite in 100 ng total carnation genomic DNA, corresponding to about 79 copies of the carnation haploid genome; the limit of detection and quantification of the quantitative PCR assay were estimated to be 38 and 190 copies of haploid carnation genomic DNA, respectively. Carnation samples with different contents of genetically modified components were quantified and the bias between the observed and true values of three samples were lower than the acceptance criterion (GMO detection method. These results indicated that these event-specific methods would be useful for the identification and quantification of the GMO carnation Moonlite.

  19. Performance of a polymer coated silicon microarray for simultaneous detection of food allergen-specific IgE and IgG4.

    Science.gov (United States)

    Sievers, S; Cretich, M; Gagni, P; Ahrens, B; Grishina, G; Sampson, H A; Niggemann, B; Chiari, M; Beyer, K

    2017-08-01

    Microarray-based component-resolved diagnostics (CRD) has become an accepted tool to detect allergen-specific IgE sensitization towards hundreds of allergens in parallel from one drop of serum. Nevertheless, specificity and sensitivity as well as a simultaneous detection of allergen-specific IgG 4 , as a potential parameter for tolerance development, remain to be optimized. We applied the recently introduced silicon chip coated with a functional polymer named copoly(DMA-NAS-MAPS) to the simultaneous detection of food allergen-specific IgE and IgG 4 , and compared it with ImmunoCAP and ImmunoCAP ISAC. Inter- and intraslide variation, linearity of signal and working range, sensitivity and application of internal calibrations for IgE and IgG 4 were assessed. Native and recombinant allergenic proteins from hen's egg and cow's milk were spotted on silicon chips coated with copoly(DMA-NAS-MAPS) along with known concentrations for human IgE and IgG 4 . A serum pool and 105 patient samples were assessed quantitatively and semi-quantitatively with the ImmunoCAP and ImmunoCAP ISAC and correlated with IgE- and IgG 4 -specific fluorescence on silicon microarrays. Allergen-specific IgE and IgG 4 were detected in parallel using two fluorescent dyes with no crosstalk. Results from the ImmunoCAP correlated better with microarray fluorescence than with ImmunoCAP ISAC except for the allergen ovomucoid. The working range of the silicon microarray for total hen's egg-specific IgE was comparable to the range of 0.1 to >100 kU A /L of the ImmunoCAP system, whereas for total cow's milk, the silicon microarray was less sensitive. Detectable allergen-specific IgG 4 could be determined only for low concentrations, but still correlated positively with ImmunoCAP results. We confirmed the ability of the polymer coated silicon microarray to be comparably sensitive to the ImmunoCAP ISAC for various food allergens. This suggests that the copoly(DMA-NAS-MAPS) microarray is a low-cost, self

  20. Development and Validation of a TaqMan Real-Time PCR Assay for the Specific Detection and Quantification of Fusarium fujikuroi in Rice Plants and Seeds.

    Science.gov (United States)

    Carneiro, Greice Amaral; Matić, Slavica; Ortu, Giuseppe; Garibaldi, Angelo; Spadaro, Davide; Gullino, Maria Lodovica

    2017-07-01

    Bakanae disease, which is caused by the seedborne pathogen Fusarium fujikuroi, is found throughout the world on rice. A TaqMan real-time PCR has been developed on the TEF 1-α gene to detect F. fujikuroi in different rice tissues. Three primer/probe sets were tested. The selected set produced an amplicon of 84 bp and was specific for F. fujikuroi with respect to eight Fusarium species of rice and six other rice common pathogens. The assay was validated for specificity, selectivity, sensitivity, repeatability, and reproducibility. The detection limit was set at 27.5 fg of DNA, which is approximately equivalent to one haploid genome of F. fujikuroi. The developed TaqMan real-time assay was able to efficiently detect and quantify F. fujikuroi from rice culms, leaves, roots, and seeds. At 1 week post-germination (wpg), the pathogen was more diffused in the green tissues, while at 3 wpg it was uniformly spread also in the roots. The highest concentration of F. fujikuroi was measured in the M6 cultivar, which showed around 1,450 fungal cells/g. The assay was sufficiently sensitive to detect a few genomic equivalents in the rice seeds, corresponding to 9.89 F. fujikuroi cells/g. The assay permitted bakanae disease to be detected in asymptomatic tissues at the early rice development stages.

  1. Development of degenerate and species-specific primers for the differential and simultaneous RT-PCR detection of grapevine-infecting nepoviruses of subgroups A, B and C.

    Science.gov (United States)

    Digiaro, Michele; Elbeaino, Toufic; Martelli, Giovanni Paolo

    2007-04-01

    Based on the nucleotide sequence homology of RNA-1 and RNA-2 of nepoviruses isolated from grapevines, three sets of degenerate primers, one for each of the three subgroups of the genus (A, B and C), were designed and proved effective for RT-PCR detection of subgroups in infected grapevines and herbaceous hosts. Primers designed specifically for detecting subgroup A species amplified a fragment of 255 bp from samples infected by Grapevine fanleaf virus (GFLV), Arabis mosaic virus (ArMV), Tobacco ringspot virus (TRSV) and Grapevine deformation virus (GDefV), but not from samples infected by other nepovirus species. Similarly, primers for detection of subgroup B nepoviruses amplified a 390 bp product from samples infected by Grapevine chrome mosaic virus (GCMV), Tomato black ring virus (TBRV), Grapevine Anatolian ringspot virus (GARSV) and Artichoke Italian latent virus (AILV). The third set of primers amplified a 640 bp fragment, only from samples infected by subgroup C nepoviruses, i.e Tomato ringspot virus (ToRSV) Grapevine Bulgarian latent virus (GBLV), and Grapevine Tunisian ringspot virus (GTRSV). These primers were able to detect simultaneously all viral species belonging to the same subgroup and to discriminate species of different subgroups. Multiplex-PCR detection of subgroup A and B nepoviruses was obtained using a specific primer (sense for subgroup A and antisense for subgroup B) for each of the species of the same subgroup in combination with the degenerate subgroup-specific primers. In this way it was possible to detect four different viral species in single samples containing mixtures of viruses of the same subgroup. In particular, for viruses of subgroup A (TRSV, GFLV, ArMV and GDefV) amplicons of 190, 259, 301 and 371 bp were obtained, whereas amplicons of 190, 278, 425 and 485 bp, respectively, were obtained from samples infected with viruses of subgroup B (GCMV, AILV, GARSV and TBRV).

  2. Incidentally detected enhancing lesions found in breast MRI: analysis of apparent diffusion coefficient and T2 signal intensity significantly improves specificity

    Energy Technology Data Exchange (ETDEWEB)

    Arponen, Otso; Masarwah, Amro; Taina, Mikko [Kuopio University Hospital, Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Kuopio University Hospital, University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Sutela, Anna; Koenoenen, Mervi; Hakumaeki, Juhana; Sudah, Mazen [Kuopio University Hospital, Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Sironen, Reijo [Kuopio University Hospital, Kuopio University Hospital, Department of Pathology, PO Box 1777, Kuopio (Finland); Kuopio University Hospital, University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Clinical Pathology and Forensic Medicine, PO Box 1777, Kuopio (Finland); University of Eastern Finland, Cancer Center of Eastern Finland, Kuopio (Finland); Vanninen, Ritva [Kuopio University Hospital, Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Kuopio University Hospital, University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); University of Eastern Finland, Cancer Center of Eastern Finland, Kuopio (Finland)

    2016-12-15

    To evaluate the value of adding T2- and diffusion-weighted imaging (DWI) to the BI-RADS registered classification in MRI-detected lesions. This retrospective study included 112 consecutive patients who underwent 3.0T structural breast MRI with T2- and DWI on the basis of EUSOMA recommendations. Morphological and kinetic features, T2 signal intensity (T2 SI) and apparent diffusion coefficient (ADC) findings were assessed. Thirty-three (29.5 %) patients (mean age 57.0 ± 12.7 years) had 36 primarily MRI-detected incidental lesions of which 16 (44.4 %) proved to be malignant. No single morphological or kinetic feature was associated with malignancy. Both low T2 SI (P = 0.009) and low ADC values (≤0.87 x 10{sup -3} mm{sup 2}s{sup -1}, P < 0.001) yielded high specificity (80.0 %/80.0 %). The BI-RADS classification supplemented with information from DWI and T2-WI improved the diagnostic performance of the BI-RADS classification as sensitivity remained 100 % and specificity improved from 30 % to 65.0 %. The numbers of false positive lesions declined from 39 % (N = 14) to 19 % (N = 7). MRI-detected incidental lesions may be challenging to characterize as they have few specific malignancy indicating features. The specificity of MRI can be improved by incorporating T2 SI and ADC values into the BI-RADS assessment. (orig.)

  3. Quantum dots immunofluorescence histochemical detection of EGFR gene mutations in the non-small cell lung cancers using mutation-specific antibodies

    Directory of Open Access Journals (Sweden)

    Qu YG

    2014-12-01

    Full Text Available Yan-Gang Qu,1 Qian Zhang,2 Qi Pan,3 Xian-Da Zhao,4 Yan-Hua Huang,2 Fu-Chun Chen,3 Hong-Lei Chen41Department of Pathology, The Central Hospital of Enshi Autonomous Prefecture, Enshi, 2Department of Molecular Pathology, Wuhan Nano Tumor Diagnosis Engineering Research Center, Wuhan, Hubei, People’s Republic of China; 3Department of Thoracosurgery, Traditional Chinese Medical Hospital of Wenling, Wenling, Zhejiang, People’s Republic of China; 4Department of Pathology, School of Basic Medical Science, Wuhan University, Wuhan, Hubei, People’s Republic of ChinaBackground: Epidermal growth factor receptor (EGFR mutation status plays an important role in therapeutic decision making for non-small cell lung cancer (NSCLC patients. Since EGFR mutation-specific antibodies (E746-A750del and L858R have been developed, EGFR mutation detection by immunohistochemistry (IHC is a suitable screening test. On this basis, we want to establish a new screening test, quantum dots immunofluorescence histochemistry (QDs-IHC, to assess EGFR gene mutation in NSCLC tissues, and we compared it to traditional IHC and amplification refractory mutation system (ARMS.Materials and methods: EGFR gene mutations were detected by QDs-IHC, IHC, and ADx-ARMS in 65 cases of NSCLC composed of 55 formalin-fixed, paraffin-embedded specimens and ten pleural effusion cell blocks, including 13 squamous cell carcinomas, two adenosquamous carcinomas, and 50 adenocarcinomas.Results: Positive rates of EGFR gene mutations detected by QDs-IHC, IHC, and ADx-ARMS were 40.0%, 36.9%, and 46.2%, respectively, in 65 cases of NSCLC patients. The sensitivity of QDs-IHC when detecting EGFR mutations, as compared to ADx-ARMS, was 86.7% (26/30; the specificity for both antibodies was 100.0% (26/26. IHC sensitivity was 80.0% (24/30 and the specificity was 92.31% (24/26. When detecting EGFR mutations, QDs-IHC and ADx-ARMS had perfect consistency (κ=0.882; P<0.01. Excellent agreement was observed

  4. Novel Junction-specific and Quantifiable In Situ Detection of AR-V7 and its Clinical Correlates in Metastatic Castration-resistant Prostate Cancer.

    Science.gov (United States)

    Zhu, Yezi; Sharp, Adam; Anderson, Courtney M; Silberstein, John L; Taylor, Maritza; Lu, Changxue; Zhao, Pei; De Marzo, Angelo M; Antonarakis, Emmanuel S; Wang, Mindy; Wu, Xingyong; Luo, Yuling; Su, Nan; Nava Rodrigues, Daniel; Figueiredo, Ines; Welti, Jonathan; Park, Emily; Ma, Xiao-Jun; Coleman, Ilsa; Morrissey, Colm; Plymate, Stephen R; Nelson, Peter S; de Bono, Johann S; Luo, Jun

    2018-05-01

    Androgen receptor splice variant 7 (AR-V7) has been implicated in resistance to abiraterone and enzalutamide treatment in men with metastatic castration-resistant prostate cancer (mCRPC). Tissue- or cell-based in situ detection of AR-V7, however, has been limited by lack of specificity. To address current limitations in precision measurement of AR-V7 by developing a novel junction-specific AR-V7 RNA in situ hybridization (RISH) assay compatible with automated quantification. We designed a RISH method to visualize single splice junctions in cells and tissue. Using the validated assay for junction-specific detection of the full-length AR (AR-FL) and AR-V7, we generated quantitative data, blinded to clinical data, for 63 prostate tumor biopsies. We evaluated clinical correlates of AR-FL/AR-V7 measurements, including association with prostate-specific antigen progression-free survival (PSA-PFS) and clinical and radiographic progression-free survival (PFS), in a subset of patients starting treatment with abiraterone or enzalutamide following biopsy. Quantitative AR-FL/AR-V7 data were generated from 56 of the 63 (88.9%) biopsy specimens examined, of which 44 were mCRPC biopsies. Positive AR-V7 signals were detected in 34.1% (15/44) mCRPC specimens, all of which also co-expressed AR-FL. The median AR-V7/AR-FL ratio was 11.9% (range 2.7-30.3%). Positive detection of AR-V7 was correlated with indicators of high disease burden at baseline. Among the 25 CRPC biopsies collected before treatment with abiraterone or enzalutamide, positive AR-V7 detection, but not higher AR-FL, was significantly associated with shorter PSA-PFS (hazard ratio 2.789, 95% confidence interval 1.12-6.95; p=0.0081). We report for the first time a RISH method for highly specific and quantifiable detection of splice junctions, allowing further characterization of AR-V7 and its clinical significance. Higher AR-V7 levels detected and quantified using a novel method were associated with poorer response to

  5. Specific detection of Pasteurella multocida in chickens with fowl cholera and in pig lung tissues using fluorescent rRNA in situ hybridization

    DEFF Research Database (Denmark)

    Mbuthia, P.G.; Christensen, H.; Boye, Mette

    2001-01-01

    in formalin-fixed paraffin-embedded lung tissues from experimental fowl cholera in chickens and infections in pigs. In chicken lung tissues P. multocida cells were detected singly, in pairs, as microcolonies, and as massive colonies within air capillaries (septa and lumen), parabronchial septa, and blood...... and fast method for specific detection of P. multocida in histological formalin-fixed tissues. The test was replicable and reproducible and is recommended as a supplementary test for diagnosis and as a tool in pathogenesis studies of fowl cholera and respiratory tract infections in pigs due to P. multocida....

  6. Detecting a low prevalence of latent tuberculosis among health care workers in Denmark detected by M. tuberculosis specific IFN-gamma whole-blood test

    DEFF Research Database (Denmark)

    Soborg, Bolette; Andersen, Aase B; Larsen, Helle K

    2007-01-01

    The study was designed to estimate prevalence of tuberculosis infection among health care workers, using the tuberculin skin test (TST) and the new M. tuberculosis specific diagnostic whole-blood test and to identify possible risk factors. Employees at 2 departments of infectious diseases...... as the remaining 45 TST positive participants showed no sign of active tuberculous disease and were allocated to 6-month clinical follow-up, without medical therapy. Today, 1.5 y later, all remain healthy. The high rate of positive TST among health care workers was most probably due to BCG vaccination...

  7. Comparison of the performance of five different immunoassays to detect specific antibodies against emerging atypical bovine pestivirus

    DEFF Research Database (Denmark)

    Larska, Magdalena; Polak, Mirosław P.; Liu, Lihong

    2013-01-01

    Bovine pestiviruses represent a considerably variable group. In addition to the two accepted species BVDV-1 and BVDV-2, a number of atypical bovine pestiviruses have been detected both in foetal calf sera and in field samples. The sera collected during the initial six weeks of experimental...... infection of calves with atypical pestivirus, BVDV-1 and a combination of both viruses have been examined by routine and new diagnostic tests to validate their robustness and sensitivity. As expected, virus neutralization tests using homologous virus were able to differentiate the two groups infected...... by BVDV-1 or atypical pestivirus, whereas the animals inoculated with a mixture of these two viruses had a reaction pattern very similar to the homologous virus alone. It was found that immunoassays using whole virus and polyclonal antibodies are the most robust, but all tests examined were able to detect...

  8. Application of functionalized lanthanide-based nanoparticles for the detection of okadaic acid-specific immunoglobulin G.

    Science.gov (United States)

    Stipić, Filip; Pletikapić, Galja; Jakšić, Željko; Frkanec, Leo; Zgrablić, Goran; Burić, Petra; Lyons, Daniel M

    2015-01-29

    Marine biotoxins are widespread in the environment and impact human health via contaminated shellfish, causing diarrhetic, amnesic, paralytic, or neurotoxic poisoning. In spite of this, methods for determining if poisoning has occurred are limited. We show the development of a simple and sensitive luminescence resonance energy transfer (LRET)-based concept which allows the detection of anti-okadaic acid rabbit polyclonal IgG (mouse monoclonal IgG1) using functionalized lanthanide-based nanoparticles. Upon UV excitation, the functionalized nanoparticles were shown to undergo LRET with fluorophore-labeled anti-okadaic acid antibodies which had been captured and bound by okadaic acid-decorated nanoparticles. The linear dependence of fluorescence emission intensity with antigen-antibody binding events was recorded in the nanomolar to micromolar range, while essentially no LRET signal was detected in the absence of antibody. These results may find applications in new, cheap, and robust sensors for detecting not only immune responses to biotoxins but also a wide range of biomolecules based on antigen-antibody recognition systems. Further, as the system is based on solution chemistry it may be sufficiently simple and versatile to be applied at point-of-care.

  9. How reliable are the sup 14 C-urea breath test and specific serology for the detection of gastric campylobacter

    Energy Technology Data Exchange (ETDEWEB)

    Husebye, E; O' Leary, D; Skar, V; Melby, K [Ullevaal Sykehus, Oslo (Norway)

    1990-01-01

    Detection of gastric campylobacter by the {sup 14}C-urea breath test and serology were correlated to biopsy culture in 25 unselected outpatients referred for gastroscopy. All the 17 culture-positive patients had positive {sup 14}C-urea breath test, and 16 had positive serology. Of eight culture-negative patients, six patients had negative breath test and seven negative serology. A high degree of reproducibility was found when two subsequent breath tests were performed in 11 healthy volunteers. The breath test values obtained at 10 min showed a strong correlation to the accumulated values within 30 min. Breath sampling once, 10 min after intake of 2.5 {mu}Ci {sup 14}C-urea, seems sufficient for the detection of gastric campylobacter. The {sup 14}C-urea breath test correlates well with biopsy culture and provides a sensitive tool for the detection of gastric campylobacter. Serology also corresponds well with biopsy culture and should provide a useful tool for epidemiologic studies. 22 refs., 4 figs., 1 tab.

  10. Dynamic domains of amyloid fibrils can be site-specifically assigned with proton detected 3D NMR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Falk, Alexander S.; Siemer, Ansgar B., E-mail: asiemer@usc.edu [Keck School of Medicine of USC, Department of Biochemistry and Molecular Medicine, Zilkha Neurogenetic Institute (United States)

    2016-11-15

    Several amyloid fibrils have cores framed by highly dynamic, intrinsically disordered, domains that can play important roles for function and toxicity. To study these domains in detail using solid-state NMR spectroscopy, site-specific resonance assignments are required. Although the rapid dynamics of these domains lead to considerable averaging of orientation-dependent NMR interactions and thereby line-narrowing, the proton linewidths observed in these samples is far larger than what is regularly observed in solution. Here, we show that it is nevertheless possible to record 3D HNCO, HNCA, and HNcoCA spectra on these intrinsically disordered domains and to obtain site-specific assignments.

  11. Comparison of Rubazyme-M and MACRIA for the detection of rubella-specific IgM

    Energy Technology Data Exchange (ETDEWEB)

    Best, J.M.; Palmer, S.J.; Morgan-Capner, P.; Hodgson, J. (Saint Thomas' Hospital, London (UK))

    1984-02-01

    One hundred and eighty-six carefully selected sera were tested for rubella-specific IgM by Rubazyme-M (Abbott Diagnostics) and an M-antibody capture radioimmunoassay (MACRIA). Eleven of these sera were from cases of infectious mononucleosis, six of which gave positive results in MACRIA, while one gave a positive result in Rubazyme-M. Of the remaining 175 sera, 158 gave concordant results whilst 17 sera gave discordant results; these 17 were also tested by serum fractionation. Problems were encountered with all assay systems used. It is therefore recommended that the results of all tests for rubella-specific IgM should be interpreted with caution.

  12. Dynamic domains of amyloid fibrils can be site-specifically assigned with proton detected 3D NMR spectroscopy

    International Nuclear Information System (INIS)

    Falk, Alexander S.; Siemer, Ansgar B.

    2016-01-01

    Several amyloid fibrils have cores framed by highly dynamic, intrinsically disordered, domains that can play important roles for function and toxicity. To study these domains in detail using solid-state NMR spectroscopy, site-specific resonance assignments are required. Although the rapid dynamics of these domains lead to considerable averaging of orientation-dependent NMR interactions and thereby line-narrowing, the proton linewidths observed in these samples is far larger than what is regularly observed in solution. Here, we show that it is nevertheless possible to record 3D HNCO, HNCA, and HNcoCA spectra on these intrinsically disordered domains and to obtain site-specific assignments.

  13. Clinical outcomes of prostate cancer patients in Yokosuka City, Japan: A comparative study between cases detected by prostate-specific antigen-based screening in Yokosuka and those detected by other means.

    Science.gov (United States)

    Sakai, Naoki; Taguri, Masataka; Kobayashi, Kazuki; Noguchi, Sumio; Ikeda, Shigeru; Koh, Hideshige; Satomi, Yoshiaki; Furuhata, Akihiko

    2015-08-01

    To investigate whether prostate-specific antigen-based screening reduced the prostate cancer mortality rate in Yokosuka, Japan. We carried out a cohort study, in which we compared clinical outcomes between patients detected by prostate-specific antigen-based screening (S group n = 524) versus those detected by other means (NS group n = 1044). Clinical and pathological factors were evaluated using Cox regression analyses and the Kaplan-Meier method. A total of 1.5% (8/524) of patients in the S group and 6.7% (70/1044) of those in the NS group died from prostate cancer during follow up. A total of 8.0% (42/524) of patients in the S group and 11.4% (119/1044) in the NS group died from other causes. The 10-year cancer specific survival rates of the S and NS groups were 97% and 86%, respectively (P prostate-specific antigen 100 ng/mL or more was significantly lower in the S group than the NS group: 7.8% and 23.0%, respectively (P specific survival (hazard ratio 4.808, 95% confidence interval 1.044-22.14, P = 0.044). Prostate-specific antigen-based population screening in Yokosuka City might help to reduce the prostate cancer mortality rate. © 2015 The Japanese Urological Association.

  14. Detecting a low prevalence of latent tuberculosis among health care workers in Denmark detected by M. tuberculosis specific IFN-gamma whole-blood test

    DEFF Research Database (Denmark)

    Soborg, Bolette; Andersen, Aase B; Larsen, Helle K

    2007-01-01

    The study was designed to estimate prevalence of tuberculosis infection among health care workers, using the tuberculin skin test (TST) and the new M. tuberculosis specific diagnostic whole-blood test and to identify possible risk factors. Employees at 2 departments of infectious diseases...... as the remaining 45 TST positive participants showed no sign of active tuberculous disease and were allocated to 6-month clinical follow-up, without medical therapy. Today, 1.5 y later, all remain healthy. The high rate of positive TST among health care workers was most probably due to BCG vaccination...... TST whereas only 2 of 139 (1%) had a positive QuantiFERON TB-Gold test (QFT-TB). 42 of 106 (40%) BCG vaccinated had positive TST (> or =12 mm) compared with 2 of 27 (7%) unvaccinated persons. Among 47 persons with positive TST, 42 (89%) were BCG- vaccinated. The 2 QFT-TB positive participants as well...

  15. The effect of chloramphenicol on synthesis of ΦX 174-specific proteins and detection of the cistron A protein

    NARCIS (Netherlands)

    Mei, D. Van Der; Zandberg, J.; Jansz, H.S.

    1972-01-01

    Synthesis of ΦX 174-specific proteins in Escherichia coli H 502 was examined on sodium dodecyl sulphate-acrylamide gels by coelectrophoresis of proteins from [3H]leucine-labelled infected cells and [14C]leucine-labelled reference cells, which had been infected with ultraviolet-light irradiated

  16. Detection of specific antibody producing cells in porcine colostrum by in ovo translation of their mRNA

    International Nuclear Information System (INIS)

    Kortbeek-Jacobs, N.; Donk, H. van der

    1978-01-01

    An improved method is described for the determination of antibody producing cells in sows colostrum. The test system comprises in ovo translation of mRNA from swine colostral cells and analysis of the translation products by radioimmunoassay with specific antibodies and antigen. (C.F.)

  17. Chromosome specific DNA hybridization in suspension for flow cytometric detection of chimerism in bone marrow transplantation and leukemia

    NARCIS (Netherlands)

    G.J.A. Arkesteijn (Ger); C.A.J. Erpelinck (Claudia); A.C.M. Martens (Anton); A. Hagenbeek (Anton)

    1995-01-01

    textabstractFlow cytometry was used to measure the fluorescence intensity of nuclei that were subjected to fluorescent in situ hybridization in suspension with chromosome specific DNA probes. Paraformaldehyde-fixed nuclei were protein digested with trypsin and hybridized simultaneously with a

  18. Cancer Specific Proliferating Cell Nuclear Antigen as a Novel Diagnostic Marker for the Detection of Breast Cancer

    National Research Council Canada - National Science Library

    Hoelz, Derek

    2003-01-01

    ... (which is now referred to as the cancer-specific form of PCNA or csPCNA). Additionally, a basic form of PCNA was also observed in the malignant cells, but this isoform was the only isoform found in non-malignant cells and tissues...

  19. Genome-wide association mapping of growth dynamics detects time-specific and general quantitative trait loci

    NARCIS (Netherlands)

    Bac-Molenaar, J.A.; Vreugdenhil, D.; Granier, C.; Keurentjes, J.J.B.

    2015-01-01

    Growth is a complex trait determined by the interplay between many genes, some of which play a role at a specific moment during development whereas others play a more general role. To identify the genetic basis of growth, natural variation in Arabidopsis rosette growth was followed in 324 accessions

  20. Immuno PET/MR imaging allows specific detection of Aspergillus fumigatus lung infection in vivo

    DEFF Research Database (Denmark)

    Rolle, Anna-Maria; Hasenberg, Mike; Thornton, Christopher R.

    2016-01-01

    -infected mice allowed specific localization of lung infection when combined with PET. Optical imaging with a fluorochrome-labeled version of the mAb showed colocalization with invasive hyphae. The mAb-based newly developed PET tracer [64Cu]DOTA-JF5 distinguishedIPA from bacterial lung infections and...

  1. Maxisorp RAST. A sensitive method for detection of antigen-specific human IgE in culture fluids

    DEFF Research Database (Denmark)

    Poulsen, L K; Pedersen, M F; Malling, H J

    1989-01-01

    For determination of allergen-specific IgE in cell culture supernatants and other highly diluted IgE preparations a radioallergosorbent test (RAST) based on high adsorption polystyrene test tubes has been developed ("Maxisorp RAST"). Cladosporium herbarum extract was used as a model allergen...

  2. Detection of prostate specific antigen (PSA) in human saliva using an ultra-sensitive nanocomposite of graphene nanoplatelets with diblock-co-polymers and Au electrodes.

    Science.gov (United States)

    Khan, M S; Dighe, K; Wang, Z; Srivastava, I; Daza, E; Schwartz-Dual, A S; Ghannam, J; Misra, S K; Pan, D

    2018-02-26

    Prostate-specific antigen (PSA) is a commonly used biomarker for the detection of prostate cancer (PCa) and there are numerous data available for its invasive detection in the serum and whole blood. In this work, an electrochemical sensing method was devised to detect traces of PSA in human saliva using a hybrid nanocomposite of graphene nanoplatelets with diblock co-polymers and Au electrodes (GRP-PS 67 -b-PAA 27 -Au). The pure graphitic composition on filter paper provides significantly high electrical and thermal conductivity while PS 67 -b-PAA 27 makes an amphiphilic bridge between GRP units. The sensor utilizes the binding of an anti-PSA antibody with an antigen-PSA to act as a resistor in a circuit providing an impedance change that in turn allows for the detection and quantification of PSA in saliva samples. A miniaturized electrical impedance analyzer was interfaced with a sensor chip and the data were recorded in real-time using a Bluetooth-enabled module. This fully integrated and optimized sensing device exhibited a wide PSA range of detection from 0.1 pg mL -1 to 100 ng mL -1 (R 2 = 0.963) with a lower limit of detection of 40 fg mL -1 . The performance of the biosensor chip was validated with an enzyme-linked immunosorbent assay technique with a regression coefficient as high as 0.940. The advantages of the newly developed saliva-PSA electrical biosensor over previously reported serum-PSA electrochemical biosensors include a faster response time (3-5 min) to achieve a stable electrical signal for PSA detection, high selectivity, improved sensitivity, no additional requirement of a redox electrolyte for electron exchange and excellent shelf life. The presented sensor is aimed for clinical commercialization to detect PSA in human saliva.

  3. Indirect detection of an epitope-specific response to HIV-1 gp120 immunization in human subjects.

    Directory of Open Access Journals (Sweden)

    Evgeny Shmelkov

    Full Text Available A specific response of human serum neutralizing antibodies (nAb to a conformational epitope as a result of vaccination of human subjects with the surface envelope glycoprotein (gp120 of HIV-1 has not previously been documented. Here, we used computational analysis to assess the epitope-specific responses of human subjects, which were immunized with recombinant gp120 immunogens in the VAX003 and VAX004 clinical trials. Our computational methodology--a variation of sieve analysis--compares the occurrence of specific nAb targeted conformational 3D epitopes on viruses from infected individuals who received vaccination to the occurrence of matched epitopes in the viruses infecting placebo subjects. We specifically studied seven crystallographically defined nAb targeted conformational epitopes in the V3 loop, an immunogenic region of gp120. Of the six epitopes present in the immunogens and targeted by known monoclonal neutralizing antibodies, only the one targeted by the anti-V3 nAb 2219 exhibited a significant reduction in occurrence in vaccinated subjects compared to the placebo group. This difference occurred only in the VAX003 Thailand cohort. No difference was seen between vaccinated and placebo groups for the occurrence of an epitope that was not present in the immunogen. Thus, it can be theorized that a specific 2219-like human neutralizing antibody immune response to AIDSVAX immunization occurred in the VAX003 cohort, and that this response protected subjects from a narrow subset of HIV-1 viruses circulating in Thailand in the 1990s and bearing the conformational epitope targeted by the neutralizing antibody 2219.

  4. Evaluation of a high-resolution, breast-specific, small-field-of-view gamma camera for the detection of breast cancer

    International Nuclear Information System (INIS)

    Brem, R.F.; Kieper, D.A.; Rapelyea, J.A.; Majewski, S.

    2003-01-01

    Purpose: The purpose of our study is to review the state of the art in nuclear medicine imaging of the breast (scintimammography) and to evaluate a novel, high-resolution, breast-specific gamma camera (HRBGC) for the detection of suspicious breast lesions. Materials and Methods: Fifty patients with 58 breast lesions in whom a scintimammogram was clinically indicated were prospectively evaluated with a general-purpose gamma camera and a HRBGC prototype. Nuclear studies were prospectively classified as negative (normal/benign) or positive (suspicious/malignant) by two radiologists, blinded to mammographic and histologic results with both the conventional and high-resolution. All lesions were confirmed by pathology. Results: Included in this study were 30 benign and 28 malignant lesions. The sensitivity for detection of breast cancer was 64.3% (18/28) with the conventional camera and 78.6% (22/28) with the HRBGC. Specificity of both systems was 93.3% (28/30). In the 18 nonpalpable cancers, sensitivity was 55.5% (10/18) and 72.2% (13/18) with the general-purpose camera and HRBGC, respectively. In cancers ≤ 1cm, 7 of 15 were detected with the general-purpose camera and 10 of 15 with the HRBGC. Four of the cancers (median size, 8.5 mm) detected with the HRBGC were missed by the conventional camera Conclusion: Evaluation of indeterminate breasts lesions with a high resolution, breast-specific gamma camera results in improved sensitivity for the detection of cancer with greater improvement demonstrated in nonpalpable and ≤1 cm cancers

  5. Dual Recognition Strategy for Specific and Sensitive Detection of Bacteria Using Aptamer-Coated Magnetic Beads and Antibiotic-Capped Gold Nanoclusters.

    Science.gov (United States)

    Cheng, Dan; Yu, Mengqun; Fu, Fei; Han, Weiye; Li, Gan; Xie, Jianping; Song, Yang; Swihart, Mark T; Song, Erqun

    2016-01-05

    Food poisoning and infectious diseases caused by pathogenic bacteria such as Staphylococcus aureus (SA) are serious public health concerns. A method of specific, sensitive, and rapid detection of such bacteria is essential and important. This study presents a strategy that combines aptamer and antibiotic-based dual recognition units with magnetic enrichment and fluorescent detection to achieve specific and sensitive quantification of SA in authentic specimens and in the presence of much higher concentrations of other bacteria. Aptamer-coated magnetic beads (Apt-MB) were employed for specific capture of SA. Vancomycin-stabilized fluorescent gold nanoclusters (AuNCs@Van) were prepared by a simple one-step process and used for sensitive quantification of SA in the range of 32-10(8) cfu/mL with the detection limit of 16 cfu/mL via a fluorescence intensity measurement. And using this strategy, about 70 cfu/mL of SA in complex samples (containing 3 × 10(8) cfu/mL of other different contaminated bacteria) could be successfully detected. In comparison to prior studies, the developed strategy here not only simplifies the preparation procedure of the fluorescent probes (AuNCs@Van) to a great extent but also could sensitively quantify SA in the presence of much higher concentrations of other bacteria directly with good accuracy. Moreover, the aptamer and antibiotic used in this strategy are much less expensive and widely available compared to common-used antibodies, making it cost-effective. This general aptamer- and antibiotic-based dual recognition strategy, combined with magnetic enrichment and fluorescent detection of trace bacteria, shows great potential application in monitoring bacterial food contamination and infectious diseases.

  6. Patient-Specific Seizure Detection in Long-Term EEG Using Signal-Derived Empirical Mode Decomposition (EMD)-based Dictionary Approach.

    Science.gov (United States)

    Kaleem, Muhammad; Gurve, Dharmendra; Guergachi, Aziz; Krishnan, Sridhar

    2018-06-25

    The objective of the work described in this paper is development of a computationally efficient methodology for patient-specific automatic seizure detection in long-term multi-channel EEG recordings. Approach: A novel patient-specific seizure detection approach based on signal-derived Empirical Mode Decomposition (EMD)-based dictionary approach is proposed. For this purpose, we use an empirical framework for EMD-based dictionary creation and learning, inspired by traditional dictionary learning methods, in which the EMD-based dictionary is learned from the multi-channel EEG data being analyzed for automatic seizure detection. We present the algorithm for dictionary creation and learning, whose purpose is to learn dictionaries with a small number of atoms. Using training signals belonging to seizure and non-seizure classes, an initial dictionary, termed as the raw dictionary, is formed. The atoms of the raw dictionary are composed of intrinsic mode functions obtained after decomposition of the training signals using the empirical mode decomposition algorithm. The raw dictionary is then trained using a learning algorithm, resulting in a substantial decrease in the number of atoms in the trained dictionary. The trained dictionary is then used for automatic seizure detection, such that coefficients of orthogonal projections of test signals against the trained dictionary form the features used for classification of test signals into seizure and non-seizure classes. Thus no hand-engineered features have to be extracted from the data as in traditional seizure detection approaches. Main results: The performance of the proposed approach is validated using the CHB-MIT benchmark database, and averaged accuracy, sensitivity and specificity values of 92.9%, 94.3% and 91.5%, respectively, are obtained using support vector machine classifier and five-fold cross-validation method. These results are compared with other approaches using the same database, and the suitability

  7. Detection of experimental thrombi in rabbits with an 131I-labelled fibrin-specific monoclonal antibody

    International Nuclear Information System (INIS)

    Walker, K.Z.; Milner, L.J.; Boniface, G.R.

    1990-01-01

    The detection of thrombi in rabbits has been investigated with 131 I-labelled DD-3B6/22, a monoclonal antibody (Mab) reactive at high affinity (Kd=2.68x10 -10 M) with human D Dimer (DD). DD-3B6/22 bound well to both 'fresh' and 'aged' human clots in an in vitro assay but showed poor binding to rabbit clots. However, reactivity was restored to rabbit blood if it was seeded, before clotting, with human DD covalently coupled to Sepharose beads. Thus, a rabbit model was developed in which blood was allowed to clot around DD-Sepharose beads introduced into the jugular vein. Gamma camera imaging showed that intact 131 I-labelled DD-3B6/22 localised to these clots within 24 h. Uptake at this time was 0.202%±0.012% injected dose per gram (%ID/g) compared with 0.086±0.018%ID/g after injection of control antibody. 131 I-labelled F(ab') 2 fragments of DD-3B6/22 allowed earlier scintigraphic detection of the clot which was evident 4 h after injection. Uptake in the clot at 24 h was 0.154±0.038% ID/g compared with 0.109±0.027% ID/g for a control F(ab') 2 . As antigen levels in the clot are estimated to be less than 300 μg DD, thus representing a very small human clot, the DD-3B6/22 Mab would appear to have a good potential for the sensitive detection of thrombi in a clinical setting. (orig.)

  8. Detection of pork adulteration in processed meat by species-specific PCR-QIAxcel procedure based on D-loop and cytb genes.

    Science.gov (United States)

    Barakat, Hassan; El-Garhy, Hoda A S; Moustafa, Mahmoud M A

    2014-12-01

    Detection of pork meat adulteration in "halal" meat products is a crucial issue in the fields of modern food inspection according to implementation of very strict procedures for halal food labelling. Present study aims at detecting and quantifying pork adulteration in both raw and cooked manufactured sausages. This is by applying an optimized species-specific PCR procedure followed by QIAxcel capillary electrophoresis system. Manufacturing experiment was designed by incorporating pork with beef meat at 0.01 to 10 % substitution levels beside beef and pork sausages as negative and positive controls, respectively. Subsequently, sausages were divided into raw and cooked sausages then subjected to DNA extraction. Results indicated that PCR amplifications of mitochondrial D-loop and cytochrome b (cytb) genes by porcine-specific primers produced 185 and 117 bp pork-specific DNA fragments in sausages, respectively. No DNA fragments were detected when PCR was applied on beef sausage DNA confirming primers specificity. For internal control, a 141-bp DNA fragment of eukaryotic 18S ribosomal RNA (rRNA) gene was amplified from pork and beef DNA templates. Although PCR followed by either QIAxcel or agarose techniques were efficient for targeted DNA fragments differentiation even as low as 0.01 % (pork/meat: w/w). For proficiency, adequacy, and performance, PCR-QIA procedure is highly sensitive, a time-saver, electronically documented, mutagenic-reagent free, of little manual errors, accurate in measuring PCR fragments length, and quantitative data supplier. In conclusion, it can be suggested that optimized PCR-QAI is considered as a rapid and sensitive method for routine pork detection and quantification in raw or processed meat.

  9. Generic and sequence-variant specific molecular assays for the detection of the highly variable Grapevine leafroll-associated virus 3.

    Science.gov (United States)

    Chooi, Kar Mun; Cohen, Daniel; Pearson, Michael N

    2013-04-01

    Grapevine leafroll-associated virus 3 (GLRaV-3) is an economically important virus, which is found in all grapevine growing regions worldwide. Its accurate detection in nursery and field samples is of high importance for certification schemes and disease management programmes. To reduce false negatives that can be caused by sequence variability, a new universal primer pair was designed against a divergent sequence data set, targeting the open reading frame 4 (heat shock protein 70 homologue gene), and optimised for conventional one-step RT-PCR and one-step SYBR Green real-time RT-PCR assays. In addition, primer pairs for the simultaneous detection of specific GLRaV-3 variants from groups 1, 2, 6 (specifically NZ-1) and the outlier NZ2 variant, and the generic detection of variants from groups 1 to 5 were designed and optimised as a conventional one-step multiplex RT-PCR assay using the plant nad5 gene as an internal control (i.e. one-step hexaplex RT-PCR). Results showed that the generic and variant specific assays detected in vitro RNA transcripts from a range of 1×10(1)-1×10(8) copies of amplicon per μl diluted in healthy total RNA from Vitis vinifera cv. Cabernet Sauvignon. Furthermore, the assays were employed effectively to screen 157 germplasm and 159 commercial field samples. Thus results demonstrate that the GLRaV-3 generic and variant-specific assays are prospective tools that will be beneficial for certification schemes and disease management programmes, as well as biological and epidemiological studies of the divergent GLRaV-3 populations. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Evaluation of dual target-specific real-time PCR for the detection of Kingella kingae in a Danish paediatric population

    DEFF Research Database (Denmark)

    de Knegt, Victoria Elizabeth; Kristiansen, Gitte Qvist; Schønning, Kristian

    2017-01-01

    BACKGROUND: We aimed to evaluate the relevance of dual target real-time polymerase chain (PCR) assays targeting the rtxA and cpn60 genes of the paediatric pathogen Kingella kingae. We also studied for the first time the clinical and epidemiological features of K. kingae infections in a Danish pop......-value: peak in autumn. CONCLUSION: Dual target-specific real-time PCR markedly improved the detection of K. kingae in clinical specimens when compared to culture methods....

  11. A new restriction endonuclease-based method for highly-specific detection of DNA targets from methicillin-resistant Staphylococcus aureus.

    Directory of Open Access Journals (Sweden)

    Maria W Smith

    Full Text Available PCR multiplexing has proven to be challenging, and thus has provided limited means for pathogen genotyping. We developed a new approach for analysis of PCR amplicons based on restriction endonuclease digestion. The first stage of the restriction enzyme assay is hybridization of a target DNA to immobilized complementary oligonucleotide probes that carry a molecular marker, horseradish peroxidase (HRP. At the second stage, a target-specific restriction enzyme is added, cleaving the target-probe duplex at the corresponding restriction site and releasing the HRP marker into solution, where it is quantified colorimetrically. The assay was tested for detection of the methicillin-resistant Staphylococcus aureus (MRSA pathogen, using the mecA gene as a target. Calibration curves indicated that the limit of detection for both target oligonucleotide and PCR amplicon was approximately 1 nM. Sequences of target oligonucleotides were altered to demonstrate that (i any mutation of the restriction site reduced the signal to zero; (ii double and triple point mutations of sequences flanking the restriction site reduced restriction to 50-80% of the positive control; and (iii a minimum of a 16-bp target-probe dsDNA hybrid was required for significant cleavage. Further experiments showed that the assay could detect the mecA amplicon from an unpurified PCR mixture with detection limits similar to those with standard fluorescence-based qPCR. Furthermore, addition of a large excess of heterologous genomic DNA did not affect amplicon detection. Specificity of the assay is very high because it involves two biorecognition steps. The proposed assay is low-cost and can be completed in less than 1 hour. Thus, we have demonstrated an efficient new approach for pathogen detection and amplicon genotyping in conjunction with various end-point and qPCR applications. The restriction enzyme assay may also be used for parallel analysis of multiple different amplicons from the same

  12. New colorimetric and fluorometric sensing strategy based on the anisotropic growth of histidine-mediated synthesis of gold nanoclusters for iodide-specific detection.

    Science.gov (United States)

    Wang, Yifeng; Zhu, Haiyan; Yang, Xiaoming; Dou, Yao; Liu, Zhongde

    2013-04-07

    Iodide, as a biologically important anion, it remains a worthwhile yet challenging undertaking to find a sensitive and specific approach to provide a technically simple iodide detection. In this article, it was found that no other ions than iodide-induced anisotropic growth of gold nanocrystals (AuNCs) originated from a small molecule, histidine-mediated synthesis of AuNCs, were observed. Simultaneously, it is accompanied by the fluorescence quenching of AuNCs and the naked-eye visible color change. Therefore, a new colorimetric and fluorometric sensing strategy was developed for the iodide-specific detection. Compared with currently reported methods, the present one displays the advantages of the visual detection and simplicity. The quenched fluorescence and enhanced surface plasmon resonance absorbance were found to be proportional to the iodide concentration over the range of 0.8-60 and 1.2-50 μM with a detection limit (3σ) of 118 nM and 215 nM, respectively.

  13. The DNA-instability test as a specific marker of malignancy and its application to detect cancer clones in borderline malignancy

    Directory of Open Access Journals (Sweden)

    M Fukuda

    2009-06-01

    Full Text Available Recent progress in cytogenetic and biochemical mutator assay technologies has enabled us to detect single gene alterations and gross chromosomal rearrangements, and it became clear that all cancer cells are genetically unstable. In order to detect the genome-wide instability of cancer cells, a new simple method, the DNA-instability test, was developed. The methods to detect genomic instability so far reported have only demonstrated the presence of qualitative and quantitative alterations in certain specific genomic loci. In contrast to these commonly used methods to reveal the genomic instability at certain specific DNA regions, the newly introduced DNA-instability test revealed the presence of physical DNA-instability in the entire DNA molecule of a cancer cell nucleus as revealed by increased liability to denature upon HCl hydrolysis or formamide exposure. When this test was applied to borderline malignancies, cancer clones were detected in all cases at an early-stage of cancer progression. We proposed a new concept of “procancer” clones to define those cancer clones with “functional atypia” showing positivities for various cancer markers, as well as DNA-instability testing, but showing no remarkable ordinary “morphological atypia” which is commonly used as the basis of histopathological diagnosis of malignancy.

  14. Methodology for Detecting Malfunctions and Evaluating the Maintenance Effectiveness in Wind Turbine Generator Bearings Using Generic versus Specific Models from SCADA Data

    Directory of Open Access Journals (Sweden)

    Miguel A. Rodríguez-López

    2018-03-01

    Full Text Available This article offers reasons to defend the use of generic behavior models as opposed to specific models in applications to determine component degradation. The term generic models refers to models based on operating data from various units, whereas specific models are calculated using operating data taken from a single unit. Moreover, generic models, used in combination with a status indicator, show excellent capacity for detecting anomalies in the equipment and for evaluating the effectiveness of the maintenance actions, resulting in lower development and maintenance costs for the operating firm. Artificial neural networks and moving means were used to calculate the degradation indicators, based on the remainders in the model. The models were developed from operating data from fourteen wind turbines monitored over several years, and applied to the detection of faults in the bearings on the non-drive end of the generator. The use of generic models may not be recommendable for detecting faults in all cases, and the suitability will depend greatly on the context of the methodology developed to detect each type of fault, according to the element causing the fault and the fault mode, since each methodology requires a greater or lesser degree of precision in the model.

  15. Development of Candida-Specific Real-Time PCR Assays for the Detection and Identification of Eight Medically Important Candida Species.

    Science.gov (United States)

    Zhang, Jing; Hung, Guo-Chiuan; Nagamine, Kenjiro; Li, Bingjie; Tsai, Shien; Lo, Shyh-Ching

    2016-01-01

    Culture-based identification methods have been the gold standard for the diagnosis of fungal infection. Currently, molecular technologies such as real-time PCR assays with short turnaround time can provide desirable alternatives for the rapid detection of Candida microbes. However, most of the published PCR primer sets are not Candida specific and likely to amplify DNA from common environmental contaminants, such as Aspergillus microbes. In this study, we designed pan-Candida primer sets based on the ribosomal DNA-coding regions conserved within Candida but distinct from those of Aspergillus and Penicillium. We demonstrate that the final two selected pan-Candida primer sets would not amplify Aspergillus DNA and could be used to differentiate eight medically important Candida pathogens in real-time PCR assays based on their melting profiles, with a sensitivity of detection as low as 10 fg of Candida genomic DNA. Moreover, we further evaluated and selected species-specific primer sets covering Candida albicans, Candida glabrata, Candida tropicalis, and Candida dubliniensis and show that they had high sensitivity and specificity. These real-time PCR primer sets could potentially be assembled into a single PCR array for the rapid detection of Candida species in various clinical settings, such as corneal transplantation.

  16. 16S rRNA-targeted probes for specific detection of Thermoanaerobacterium spp., Thermoanaerobacterium thermosaccharolyticum, and Caldicellulosiruptor spp. by fluorescent in situ hybridization in biohydrogen producing systems

    Energy Technology Data Exchange (ETDEWEB)

    O-Thong, Sompong [Department of Environmental Engineering, Technical University of Denmark, Bygningstorvet Bg 115, DK-2800, Kgs Lyngby (Denmark); Department of Biology, Faculty of Science, Thaksin University, Patthalung 93110 (Thailand); Prasertsan, Poonsuk [Department of Industrial Biotechnology, Faculty of Agro-Industry, Prince of Songkla University, Hat-Yai, Songkhla 90112 (Thailand); Karakashev, Dimitar; Angelidaki, Irini [Department of Environmental Engineering, Technical University of Denmark, Bygningstorvet Bg 115, DK-2800, Kgs Lyngby (Denmark)

    2008-11-15

    16S rRNA gene targeted oligonucleotide probes for specific detection of genera Thermoanaerobacterium (Tbm1282), Caldicellulosiruptor (Ccs432), and specie Thermoanaerobacterium thermosaccharolyticum (Tbmthsacc184) were designed and used to monitor the spatial distribution of hydrogen producing bacteria in sludge and granules from anaerobic reactors. The designed probes were checked for their specificity and then validated using fluorescence in situ hybridization with target microorganisms and non-target microorganisms. Thermoanaerobacterium spp., T. thermosaccharolyticum and Caldicellulosiruptor spp. were detected with the probes designed with coverage of 75%, 100% and 93%, respectively. Thermophilic (60 C) hydrogen producing reactors, one fed with sucrose and another, fed with palm oil mill effluent comprised of following major groups of hydrogen producers: Thermoanaerobacterium spp. (49% and 36%), T. thermosaccharolyticum (16% and 10%), phylum Firmicutes (low G+C) gram positive bacteria (15% and 27%). Extreme-thermophilic (70 C) hydrogen producing reactors, one fed with xylose and another, fed with lignocellulosic hydrolysate comprised of following major groups of hydrogen producers: Caldicellulosiruptor spp. (40.5% and 20.5%), phylum Firmicutes (low G+C) gram positive bacteria (17% and 20%), Archaea (7% and 8.5%), and Thermoanaerobacterium spp. (0% and 5%). Results obtained, showed good applicability of the probes Tbm1282, Tbmthsacc184 and Ccs432 for specific detection and quantification of thermophilic and extreme-thermophilic hydrogen producers in complex environments. (author)

  17. A quantitative and direct PCR assay for the subspecies-specific detection of Clavibacter michiganensis subsp. michiganensis based on a ferredoxin reductase gene.

    Science.gov (United States)

    Cho, Min Seok; Lee, Jang Ha; Her, Nam Han; Kim, Changkug; Seol, Young-Joo; Hahn, Jang Ho; Baeg, Ji Hyoun; Kim, Hong Gi; Park, Dong Suk

    2012-06-01

    The Gram-positive bacterium Clavibacter michiganensis subsp. michiganensis is the causal agent of canker disease in tomato. Because it is very important to control newly introduced inoculum sources from commercial materials, the specific detection of this pathogen in seeds and seedlings is essential for effective disease control. In this study, a novel and efficient assay for the detection and quantitation of C. michiganensis subsp. michiganensis in symptomless tomato and red pepper seeds was developed. A pair of polymerase chain reaction (PCR) primers (Cmm141F/R) was designed to amplify a specific 141 bp fragment on the basis of a ferredoxin reduct