  1. Specific calibration problems for gammaspectrometric measurements of low-level radioactivity in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, D [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Wershofen, H [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)

    1997-03-01

    Gammaspectrometric measurements of low-level radioactivity in environmental samples are always done in a close source detector geometry. This geometry causes coincidence-summing effects for measurements of multi-photon emitting nuclides. The measurements of radioactivity in environmental samples are also influenced by the absorption of photons in the materials which have to be analysed. Both effects must be taken into account by correction factors with respect to an energy-specific calibration of the detector system for a given geometry and a given composition of the calibration source. The importance of these corrections is emphasized. It is the aim of the present paper to compare different experimental and theoretical methods for the determination of these correction factors published by various authors and to report about efforts to refine them. (orig.)

  2. Some problems in calibrating surface contamination meters

    International Nuclear Information System (INIS)

    Chen Zigen; LI Xingyuan; Shuai Xiaoping.

    1984-01-01

    It is necessary that instruments are calibrated accurately in order to obtain reliable survey data of surface contamination. Some problems in calibrating surface contamination meters are expounded in this paper. Measurement comparison for beta surface contamination meters is organized within limited scope, thus survey quality is understood, questions are discovered, significance of calibration is expounded further. (Author)

  3. Redundant interferometric calibration as a complex optimization problem

    Science.gov (United States)

    Grobler, T. L.; Bernardi, G.; Kenyon, J. S.; Parsons, A. R.; Smirnov, O. M.

    2018-05-01

    Observations of the redshifted 21 cm line from the epoch of reionization have recently motivated the construction of low-frequency radio arrays with highly redundant configurations. These configurations provide an alternative calibration strategy - `redundant calibration' - and boost sensitivity on specific spatial scales. In this paper, we formulate calibration of redundant interferometric arrays as a complex optimization problem. We solve this optimization problem via the Levenberg-Marquardt algorithm. This calibration approach is more robust to initial conditions than current algorithms and, by leveraging an approximate matrix inversion, allows for further optimization and an efficient implementation (`redundant STEFCAL'). We also investigated using the preconditioned conjugate gradient method as an alternative to the approximate matrix inverse, but found that its computational performance is not competitive with respect to `redundant STEFCAL'. The efficient implementation of this new algorithm is made publicly available.

  4. CVD calibration light systems specifications. Rev. 0

    International Nuclear Information System (INIS)

    Mcllwain, A. K.

    1992-04-01

    Two prototype Cerenkov Viewing Device Calibration Light systems for the Mark IV CVD have been fabricated. They consist of a maintenance unit that will be used by the IAEA maintenance staff and a field unit that will be used by IAEA inspectors. More detailed information on the design of the calibration units can be obtained from the document SSP-39 and additional information on the Mark IV CVD can be obtained from the operating manual published as Canadian Safeguards Support Program document CSSP 6. The specifications refer to the prototype units which will be demonstrated to the IAEA in 1992 May. Based upon the feedback from the IAEA, the instruments will be changed in the final production models to provide devices that more closely satisfy the needs of the end users

  5. Code Calibration as a Decision Problem

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Kroon, I. B.; Faber, Michael Havbro

    1993-01-01

    Calibration of partial coefficients for a class of structures where no code exists is considered. The partial coefficients are determined such that the difference between the reliability for the different structures in the class considered and a target reliability level is minimized. Code...... calibration on a decision theoretical basis is discussed. Results from code calibration for rubble mound breakwater designs are shown....

  6. Comparison of different calibration methods suited for calibration problems with many variables

    DEFF Research Database (Denmark)

    Holst, Helle

    1992-01-01

    This paper describes and compares different kinds of statistical methods proposed in the literature as suited for solving calibration problems with many variables. These are: principal component regression, partial least-squares, and ridge regression. The statistical techniques themselves do...

  7. Site-specific calibration of the Hanford personnel neutron dosimeter

    International Nuclear Information System (INIS)

    Endres, A.W.; Brackenbush, L.W.; Baumgartner, W.V.; Rathbone, B.A.

    1994-10-01

    A new personnel dosimetry system, employing a standard Hanford thermoluminescent dosimeter (TLD) and a combination dosimeter with both CR-39 nuclear track and TLD-albedo elements, is being implemented at Hanford. Measurements were made in workplace environments in order to verify the accuracy of the system and establish site-specific factors to account for the differences in dosimeter response between the workplace and calibration laboratory. Neutron measurements were performed using sources at Hanford's Plutonium Finishing Plant under high-scatter conditions to calibrate the new neutron dosimeter design to site-specific neutron spectra. The dosimeter was also calibrated using bare and moderated 252 Cf sources under low-scatter conditions available in the Hanford Calibration Laboratory. Dose equivalent rates in the workplace were calculated from spectrometer measurements using tissue equivalent proportional counter (TEPC) and multisphere spectrometers. The accuracy of the spectrometers was verified by measurements on neutron sources with calibrations directly traceable to the National Institute of Standards and Technology (NIST)

  8. Calibrating corneal material model parameters using only inflation data: an ill-posed problem

    CSIR Research Space (South Africa)

    Kok, S

    2014-08-01

    Full Text Available is to perform numerical modelling using the finite element method, for which a calibrated material model is required. These material models are typically calibrated using experimental inflation data by solving an inverse problem. In the inverse problem...

  9. Cumulative error models for the tank calibration problem

    International Nuclear Information System (INIS)

    Goldman, A.; Anderson, L.G.; Weber, J.

    1983-01-01

    The purpose of a tank calibration equation is to obtain an estimate of the liquid volume that corresponds to a liquid level measurement. Calibration experimental errors occur in both liquid level and liquid volume measurements. If one of the errors is relatively small, the calibration equation can be determined from wellknown regression and calibration methods. If both variables are assumed to be in error, then for linear cases a prototype model should be considered. Many investigators are not familiar with this model or do not have computing facilities capable of obtaining numerical solutions. This paper discusses and compares three linear models that approximate the prototype model and have the advantage of much simpler computations. Comparisons among the four models and recommendations of suitability are made from simulations and from analyses of six sets of experimental data

  10. Calibration

    International Nuclear Information System (INIS)

    Greacen, E.L.; Correll, R.L.; Cunningham, R.B.; Johns, G.G.; Nicolls, K.D.

    1981-01-01

    Procedures common to different methods of calibration of neutron moisture meters are outlined and laboratory and field calibration methods compared. Gross errors which arise from faulty calibration techniques are described. The count rate can be affected by the dry bulk density of the soil, the volumetric content of constitutional hydrogen and other chemical components of the soil and soil solution. Calibration is further complicated by the fact that the neutron meter responds more strongly to the soil properties close to the detector and source. The differences in slope of calibration curves for different soils can be as much as 40%

  11. Some problems of calibration technique in charged particle activation analysis

    International Nuclear Information System (INIS)

    Krasnov, N.N.; Zatolokin, B.V.; Konstantinov, I.O.

    1977-01-01

    It is shown that three different approaches to calibration technique based on the use of average cross-section, equivalent target thickness and thick target yield are adequate. Using the concept of thick target yield, a convenient charged particle activation equation is obtained. The possibility of simultaneous determination of two impurities, from which the same isotope is formed, is pointed out. The use of the concept of thick target yield facilitates the derivation of a simple formula for an absolute and comparative methods of analysis. The methodical error does not exceed 10%. Calibration technique and determination of expected sensitivity based on the thick target yield concept is also very convenient because experimental determination of thick target yield values is a much simpler procedure than getting activation curve or excitation function. (T.G.)

  12. Absolute mass scale calibration in the inverse problem of the physical theory of fireballs.

    Science.gov (United States)

    Kalenichenko, V. V.

    A method of the absolute mass scale calibration is suggested for solving the inverse problem of the physical theory of fireballs. The method is based on the data on the masses of the fallen meteorites whose fireballs have been photographed in their flight. The method may be applied to those fireballs whose bodies have not experienced considerable fragmentation during their destruction in the atmosphere and have kept their form well enough. Statistical analysis of the inverse problem solution for a sufficiently representative sample makes it possible to separate a subsample of such fireballs. The data on the Lost City and Innisfree meteorites are used to obtain calibration coefficients.

  13. Recent developments in the specification and achievement of realistic neutron calibration fields

    International Nuclear Information System (INIS)

    Chartier, J.L.; Kluges, H.; Wiegel, B.; Schraube, H.

    1997-01-01

    In order to calibrate more accurately the neutron dosemeters involved in radiation protection, the concept of 'Realistic Neutron Calibration Fields' is considered as an appropriate alternative solution, making necessary new irradiation facilities which generate well-characterised neutron fields with energy and angular distribution replicating more closely practical workplace conditions. Several experienced laboratories have collaborated on a European project and proposed various approaches which are reviewed in this paper. A short description of the facilities currently in operation is given as well as a few characteristics of the available radiation fields. This description of the state of art is followed by a discussion of the problems to be solved for using such facilities for calibration purposes according to well-specified calibration procedures. (author)

  14. Problem specific heuristics for group scheduling problems in cellular manufacturing

    OpenAIRE

    Neufeld, Janis Sebastian

    2016-01-01

    The group scheduling problem commonly arises in cellular manufacturing systems, where parts are grouped into part families. It is characterized by a sequencing task on two levels: on the one hand, a sequence of jobs within each part family has to be identified while, on the other hand, a family sequence has to be determined. In order to solve this NP-hard problem usually heuristic solution approaches are used. In this thesis different aspects of group scheduling are discussed and problem spec...

  15. Elementary Students' Metacognitive Processes and Post-Performance Calibration on Mathematical Problem-Solving Tasks

    Science.gov (United States)

    García, Trinidad; Rodríguez, Celestino; González-Castro, Paloma; González-Pienda, Julio Antonio; Torrance, Mark

    2016-01-01

    Calibration, or the correspondence between perceived performance and actual performance, is linked to students' metacognitive and self-regulatory skills. Making students more aware of the quality of their performance is important in elementary school settings, and more so when math problems are involved. However, many students seem to be poorly…

  16. Solving the robot-world, hand-eye(s) calibration problem with iterative methods

    Science.gov (United States)

    Robot-world, hand-eye calibration is the problem of determining the transformation between the robot end effector and a camera, as well as the transformation between the robot base and the world coordinate system. This relationship has been modeled as AX = ZB, where X and Z are unknown homogeneous ...

  17. Absolute calibration of the mass scale in the inverse problem of the physical theory of fireballs

    Science.gov (United States)

    Kalenichenko, V. V.

    1992-08-01

    A method of the absolute calibration of the mass scale is proposed for solving the inverse problem of the physical theory of fireballs. The method is based on data on the masses of fallen meteorites whose fireballs have been photographed in flight. The method can be applied to fireballs whose bodies have not experienced significant fragmentation during their flight in the atmosphere and have kept their shape relatively well. Data on the Lost City and Innisfree meteorites are used to calculate the calibration coefficients.

  18. The calibration of portable and airborne gamma-ray spectrometers - theory, problems, and facilities

    International Nuclear Information System (INIS)

    Loevborg, L.

    1984-10-01

    A gamma-ray spectrometer for use in geological exploration possesses four stripping ratios and three window sensitivities which must be determined to make the instrumentation applicable for field assay or airborne measurement of potassium, uranium, and thorium contents in the ground. Survey organizations in many parts of the world perform the instrument calibration using large pads of concrete which simulate a plane ground of known radioelement concentration. Calibration and monitoring trials with twelve facilities in ten countries prove that moisture absorption, radon exhalation, and particle-size effects can offset a radiometric grade assigned to concrete whose aggregate contains an embedded radioactive mineral. These and other calibration problems are discussed from a combined theoretical and practical viewpoint. (author)

  19. Calibration is action specific but perturbation of perceptual units is not.

    Science.gov (United States)

    Pan, Jing S; Coats, Rachel O; Bingham, Geoffrey P

    2014-02-01

    G. P. Bingham and C. C. Pagano (1998, The necessity of a perception/action approach to definite distance perception: Monocular distance perception to guide reaching. Journal of Experimental Psychology: Human Perception and Performance, 24, 145-168) argued that metric space perception should be investigated using relevant action measures because calibration is an intrinsic component of perception/action that yields accurate targeted actions. They described calibration as a mapping from embodied units of perception to embodied units of action. This mapping theory yields a number of predictions. We tested two of them. The first prediction is that calibration should be action specific because what is calibrated is a mapping from perceptual units to a unit of action. Thus, calibration does not generalize to other actions. This prediction is consistent with the "action-specific approach" to calibration (D. R. Proffitt, 2008, An action specific approach to spatial perception. In R. L. Klatzky, B. MacWhinney, & M. Behrmann (Eds.), Embodiment, ego-space and action (pp. 179-202). New York, NY: Psychology Press.). The second prediction is that a change in perceptual units should generalize to all relevant actions that are guided using that perceptual information. The same perceptual units can be mapped to different actions. Change in the unit affects all relevant actions. This prediction is consistent with the "general purpose perception approach" (J. M. Loomis & J. W. Philbeck, 2008, Measuring spatial perception with spatial updating and action. In R. L. Klatzky, B. MacWhinney, & M. Behrmann (Eds.), Embodiment, ego-space and action (pp. 1-43). New York, NY: Psychology Press). In Experiment 1, two targeted actions, throwing and extended reaching were tested to determine if they were comparable in precision and in response to distorted calibration. They were. Comparing these actions, the first prediction was tested in Experiment 2 and confirmed. The second prediction was

  20. The Prediction Properties of Inverse and Reverse Regression for the Simple Linear Calibration Problem

    Science.gov (United States)

    Parker, Peter A.; Geoffrey, Vining G.; Wilson, Sara R.; Szarka, John L., III; Johnson, Nels G.

    2010-01-01

    The calibration of measurement systems is a fundamental but under-studied problem within industrial statistics. The origins of this problem go back to basic chemical analysis based on NIST standards. In today's world these issues extend to mechanical, electrical, and materials engineering. Often, these new scenarios do not provide "gold standards" such as the standard weights provided by NIST. This paper considers the classic "forward regression followed by inverse regression" approach. In this approach the initial experiment treats the "standards" as the regressor and the observed values as the response to calibrate the instrument. The analyst then must invert the resulting regression model in order to use the instrument to make actual measurements in practice. This paper compares this classical approach to "reverse regression," which treats the standards as the response and the observed measurements as the regressor in the calibration experiment. Such an approach is intuitively appealing because it avoids the need for the inverse regression. However, it also violates some of the basic regression assumptions.

  1. Modal and Mixed Specifications: Key Decision Problems and their Complexities

    DEFF Research Database (Denmark)

    Antonik, Adam; Huth, Michael; Larsen, Kim Guldstrand

    2010-01-01

    , and whether all implementations of one specification are implementations of another one. For each of these decision problems we investigate the worst-case computational complexity for the modal and mixed case. We show that the first decision problem is EXPTIME-complete for modal as well as for mixed......Modal and mixed transition systems are specification formalisms that allow mixing of over- and under-approximation. We discuss three fundamental decision problems for such specifications: whether a set of specifications has a common implementation, whether a sole specification has an implementation...... specifications. We prove that the second decision problem is EXPTIME-complete for mixed specifications (while it is known to be trivial for modal ones). The third decision problem is furthermore demonstrated to be EXPTIME-complete for mixed specifications....

  2. Key to good fit: body measurement problems specific to key ...

    African Journals Online (AJOL)

    Key to good fit: body measurement problems specific to key dimensions. ... to explore and describe the problems that the South African Clothing Industry currently ... A postal survey was conducted among South African apparel and footwear ...

  3. National Uranium Resource Evaluation. General procedure for calibration and reduction of aerial gamma-ray measurements: specification BFEC 1250-B

    International Nuclear Information System (INIS)

    Purvance, D.; Novak, E.

    1983-12-01

    The information contained in this specification was acquired over the course of the US Department of Energy (DOE) National Uranium Resource Evaluation (NURE) program during the period 1974 through 1982. NURE was a program of the DOE Grand Junction Area Office to acquire and compile geologic and other information with which to assess the magnitude and distribution of uranium resources and to determine areas favorable for the occurrence of uranium in the United States. Bendix Field Engineering Corporation (BFEC) has been the operating contractor for the DOE Grand Junction facility. The requirements stipulated herein had been incorporated as contractual specifications for the various subcontractors engaged in the aerial gamma-ray surveys, which were a major aspect of the NURE program. Although this phase of NURE activities has been completed, there exists valuable knowledge gained from these years of experience in the calibration of gamma-ray spectrometer systems and in the reduction of calibration data. Specification BFEC 1250-B is being open-filed by the US Department of Energy at this time to make this knowledge available to those desiring to apply gamma-ray spectrometry to other geophysical problems

  4. Calibration of context-specific survey items to assess youth physical activity behaviour.

    Science.gov (United States)

    Saint-Maurice, Pedro F; Welk, Gregory J; Bartee, R Todd; Heelan, Kate

    2017-05-01

    This study tests calibration models to re-scale context-specific physical activity (PA) items to accelerometer-derived PA. A total of 195 4th-12th grades children wore an Actigraph monitor and completed the Physical Activity Questionnaire (PAQ) one week later. The relative time spent in moderate-to-vigorous PA (MVPA % ) obtained from the Actigraph at recess, PE, lunch, after-school, evening and weekend was matched with a respective item score obtained from the PAQ's. Item scores from 145 participants were calibrated against objective MVPA % using multiple linear regression with age, and sex as additional predictors. Predicted minutes of MVPA for school, out-of-school and total week were tested in the remaining sample (n = 50) using equivalence testing. The results showed that PAQ β-weights ranged from 0.06 (lunch) to 4.94 (PE) MVPA % (P PAQ and accelerometer MVPA at school and out-of-school ranged from -15.6 to +3.8 min and the PAQ was within 10-15% of accelerometer measured activity. This study demonstrated that context-specific items can be calibrated to predict minutes of MVPA in groups of youth during in- and out-of-school periods.

  5. A Linearized Relaxing Algorithm for the Specific Nonlinear Optimization Problem

    Directory of Open Access Journals (Sweden)

    Mio Horai

    2016-01-01

    Full Text Available We propose a new method for the specific nonlinear and nonconvex global optimization problem by using a linear relaxation technique. To simplify the specific nonlinear and nonconvex optimization problem, we transform the problem to the lower linear relaxation form, and we solve the linear relaxation optimization problem by the Branch and Bound Algorithm. Under some reasonable assumptions, the global convergence of the algorithm is certified for the problem. Numerical results show that this method is more efficient than the previous methods.

  6. Specific Cognitive Predictors of Early Math Problem Solving

    Science.gov (United States)

    Decker, Scott L.; Roberts, Alycia M.

    2015-01-01

    Development of early math skill depends on a prerequisite level of cognitive development. Identification of specific cognitive skills that are important for math development may not only inform instructional approaches but also inform assessment approaches to identifying children with specific learning problems in math. This study investigated the…

  7. Does simultaneous bilingualism aggravate children's specific language problems?

    Science.gov (United States)

    Korkman, Marit; Stenroos, Maria; Mickos, Annika; Westman, Martin; Ekholm, Pia; Byring, Roger

    2012-09-01

    There is little data on whether or not a bilingual upbringing may aggravate specific language problems in children. This study analysed whether there was an interaction of such problems and simultaneous bilingualism. Participants were 5- to 7-year-old children with specific language problems (LANG group, N = 56) or who were typically developing (CONTR group, N = 60). Seventy-three children were Swedish-Finnish bilingual and 43 were Swedish-speaking monolingual. Assessments (in Swedish) included tests of expressive language, comprehension, repetition and verbal memory. Per definition, the LANG group had lower scores than the CONTR group on all language tests. The bilingual group had lower scores than the monolingual group only on a test of body part naming. Importantly, the interaction of group (LANG or CONTR) and bilingualism was not significant on any of the language scores. Simultaneous bilingualism does not aggravate specific language problems but may result in a slower development of vocabulary both in children with and without specific language problems. Considering also advantages, a bilingual upbringing is an option also for children with specific language problems. In assessment, tests of vocabulary may be sensitive to bilingualism, instead tests assessing comprehension, syntax and nonword repetition may provide less biased methods. © 2012 The Author(s)/Acta Paediatrica © 2012 Foundation Acta Paediatrica.

  8. Applying transport-distance specific SOC distribution to calibrate soil erosion model WaTEM

    Science.gov (United States)

    Hu, Yaxian; Heckrath, Goswin J.; Kuhn, Nikolaus J.

    2016-04-01

    Slope-scale soil erosion, transport and deposition fundamentally decide the spatial redistribution of eroded sediments in terrestrial and aquatic systems, which further affect the burial and decomposition of eroded SOC. However, comparisons of SOC contents between upper eroding slope and lower depositional site cannot fully reflect the movement of eroded SOC in-transit along hillslopes. The actual transport distance of eroded SOC is decided by its settling velocity. So far, the settling velocity distribution of eroded SOC is mostly calculated from mineral particle specific SOC distribution. Yet, soil is mostly eroded in form of aggregates, and the movement of aggregates differs significantly from individual mineral particles. This urges a SOC erodibility parameter based on actual transport distance distribution of eroded fractions to better calibrate soil erosion models. Previous field investigation on a freshly seeded cropland in Denmark has shown immediate deposition of fast settling soil fractions and the associated SOC at footslopes, followed by a fining trend at the slope tail. To further quantify the long-term effects of topography on erosional redistribution of eroded SOC, the actual transport-distance specific SOC distribution observed on the field was applied to a soil erosion model WaTEM (based on USLE). After integrating with local DEM, our calibrated model succeeded in locating the hotspots of enrichment/depletion of eroded SOC on different topographic positions, much better corresponding to the real-world field observation. By extrapolating into repeated erosion events, our projected results on the spatial distribution of eroded SOC are also adequately consistent with the SOC properties in the consecutive sample profiles along the slope.

  9. Problems of calibrating measuring instruments for selective gamma-gamma logging

    International Nuclear Information System (INIS)

    Daniel, J.; Smolarova, H.

    1977-01-01

    Quantitative determination of copper content in the Novoveska Huta chalcopyrite deposit is described using selective gamma-gamma logging. Factors influencing the calibration quality are discussed. (author)

  10. Model calibration for ice sheets and glaciers dynamics: a general theory of inverse problems in glaciology

    Science.gov (United States)

    Giudici, Mauro; Baratelli, Fulvia; Vassena, Chiara; Cattaneo, Laura

    2014-05-01

    Numerical modelling of the dynamic evolution of ice sheets and glaciers requires the solution of discrete equations which are based on physical principles (e.g. conservation of mass, linear momentum and energy) and phenomenological constitutive laws (e.g. Glen's and Fourier's laws). These equations must be accompanied by information on the forcing term and by initial and boundary conditions (IBC) on ice velocity, stress and temperature; on the other hand the constitutive laws involves many physical parameters, which possibly depend on the ice thermodynamical state. The proper forecast of the dynamics of ice sheets and glaciers (forward problem, FP) requires a precise knowledge of several quantities which appear in the IBCs, in the forcing terms and in the phenomenological laws and which cannot be easily measured at the study scale in the field. Therefore these quantities can be obtained through model calibration, i.e. by the solution of an inverse problem (IP). Roughly speaking, the IP aims at finding the optimal values of the model parameters that yield the best agreement of the model output with the field observations and data. The practical application of IPs is usually formulated as a generalised least squares approach, which can be cast in the framework of Bayesian inference. IPs are well developed in several areas of science and geophysics and several applications were proposed also in glaciology. The objective of this paper is to provide a further step towards a thorough and rigorous theoretical framework in cryospheric studies. Although the IP is often claimed to be ill-posed, this is rigorously true for continuous domain models, whereas for numerical models, which require the solution of algebraic equations, the properties of the IP must be analysed with more care. First of all, it is necessary to clarify the role of experimental and monitoring data to determine the calibration targets and the values of the parameters that can be considered to be fixed

  11. Calibration and assessment of channel-specific biases in microarray data with extended dynamical range.

    Science.gov (United States)

    Bengtsson, Henrik; Jönsson, Göran; Vallon-Christersson, Johan

    2004-11-12

    Non-linearities in observed log-ratios of gene expressions, also known as intensity dependent log-ratios, can often be accounted for by global biases in the two channels being compared. Any step in a microarray process may introduce such offsets and in this article we study the biases introduced by the microarray scanner and the image analysis software. By scanning the same spotted oligonucleotide microarray at different photomultiplier tube (PMT) gains, we have identified a channel-specific bias present in two-channel microarray data. For the scanners analyzed it was in the range of 15-25 (out of 65,535). The observed bias was very stable between subsequent scans of the same array although the PMT gain was greatly adjusted. This indicates that the bias does not originate from a step preceding the scanner detector parts. The bias varies slightly between arrays. When comparing estimates based on data from the same array, but from different scanners, we have found that different scanners introduce different amounts of bias. So do various image analysis methods. We propose a scanning protocol and a constrained affine model that allows us to identify and estimate the bias in each channel. Backward transformation removes the bias and brings the channels to the same scale. The result is that systematic effects such as intensity dependent log-ratios are removed, but also that signal densities become much more similar. The average scan, which has a larger dynamical range and greater signal-to-noise ratio than individual scans, can then be obtained. The study shows that microarray scanners may introduce a significant bias in each channel. Such biases have to be calibrated for, otherwise systematic effects such as intensity dependent log-ratios will be observed. The proposed scanning protocol and calibration method is simple to use and is useful for evaluating scanner biases or for obtaining calibrated measurements with extended dynamical range and better precision. The

  12. Analytic Solution to the Problem of Aircraft Electric Field Mill Calibration

    Science.gov (United States)

    Koshak, W. J.

    2003-12-01

    It is by no means a simple task to retrieve storm electric fields from an aircraft instrumented with electric field mill sensors. The presence of the aircraft distorts the ambient field in a complicated way. Before retrievals of the storm field can be made, the field mill measurement system must be "calibrated". In other words, a relationship between impressed (i.e., ambient) electric field and mill output must be established. If this relationship can be determined, it is mathematically inverted so that ambient field can be inferred from the mill outputs. Previous studies have primarily focused on linear theories where the "relationship" between ambient field and mill output is described by a "calibration matrix" M. Each element of the matrix describes how a particular component of the ambient field is enhanced by the aircraft. For example the product MixEx is the contribution of the Ex field to the ith mill output. Similarly, net aircraft charge (described by a "charge field component" Eq) contributes an amount MiqEq to the output of the ith sensor. The central difficulty in obtaining M stems from the fact that the impressed field (Ex, Ey, Ez, Eq) is not known but is instead estimated. Typically, the aircraft is flown through a series of roll and pitch maneuvers in fair weather, and the values of the fair weather field and aircraft charge are estimated at each point along the aircraft trajectory. These initial estimates are often highly inadequate, but several investigators have improved the estimates by implementing various (ad hoc) iterative methods. Though numerical tests show that some of the iterative methods do improve the initial estimates, none of the iterative methods guarantee absolute convergence to the true values, or even to values reasonably close to the true values when measurement errors are present. In this work, the mathematical problem is solved directly by analytic means. For m mills installed on an arbitrary aircraft, it is shown that it is

  13. A Few Examples of ISPs Addressing Specific Reactor Safety Problems

    International Nuclear Information System (INIS)

    Reocreux, M.

    2008-01-01

    Four International Standard Problems which were related to safety reactor problems are briefly discussed. ISP-20 (Steam Generator Tube Rupture in DOEL 2) is a unique ISP as it is based on a real incident which occurred in a commercial Power Plant. This ISP clearly illustrated the special problems of an ISP based on a real plant, namely limited access to precise plant data, some lack in the detailed knowledge of sensor behaviour, etc. ISP-26 (ROSA IV-LSTF small break test) was an open ISP. A qualitatively good prediction of the measured events was obtained even if some modelling deficiencies were identified. ISP-27 (BETHSY Exp. 9.1 B) was a blind ISP. All important trends observed during the test were qualitatively calculated by most computer codes. However, some deficiencies in calculating some variables were evident. ISP-33 (PACTEL Natural Circulation) was an exercise with a test facility modelled on the basis of a Russian VVER 440 and with participations from Eastern and Western organisations. ISP-33 was a double-blind exercise. The simulation of some variables caused some problems although they were in principle not too complicated. Post-test calculations demonstrated significant improvements. For all the four ISPs, the influence of the code user was evident and caused some scatter in the results. A specific study was performed in ISP-26 to clarify from where those user effects were coming. The reactor safety problems related to those ISPs are detailed and the specific contribution of the ISPs to bring solutions is discussed.

  14. Nuclear data for specific problems. Part 1: Methods

    International Nuclear Information System (INIS)

    Leszczynski, Francisco

    1999-01-01

    The growing volume of basic nuclear data, methods and codes for processing these data, and the wide variety of problems where these data and codes are required, oblige to have an efficient system for managing all this information. In this work we present a new methodology for nuclear data processing, applied to neutron and photon transport calculations for specific problems. The base of the new methodology is the analysis of the requirements, following the chain: Problem-Components-Materials-Elements-Isotopes-Process-Tests-Final product (a library with processed data). This order is the inverse of the normal order followed up to date where, for performing a specific calculation, the first step is the choice of an existing data library for general purposes, without the previous steps of pre-processing data, and tests of the final library. Then, the used data are limited to the isotope content of this library, and the adaptation of material compositions and components to the data availability is necessary , performing finally the required calculations in a rather approximated form, depending on the available data. An interactive computer program for PC , is developed, for managing all the information generated by nuclear data processing, with the additional advantage of having a help tool for performing the needed analysis, before processing data calculations for specific applications. These analyses are based on the particular characteristics of each application, and the processed information of previous cases, is stored in conveniently designed data bases for an easy inspection of its contents. By means of an example of application of the new method, in this paper the methods of analysis and calculations and the tools used (computer programs, data bases and documents) are describes. (author)

  15. Does Preschool Self-Regulation Predict Later Behavior Problems in General or Specific Problem Behaviors?

    Science.gov (United States)

    Lonigan, Christopher J; Spiegel, Jamie A; Goodrich, J Marc; Morris, Brittany M; Osborne, Colleen M; Lerner, Matthew D; Phillips, Beth M

    2017-11-01

    Findings from prior research have consistently indicated significant associations between self-regulation and externalizing behaviors. Significant associations have also been reported between children's language skills and both externalizing behaviors and self-regulation. Few studies to date, however, have examined these relations longitudinally, simultaneously, or with respect to unique clusters of externalizing problems. The current study examined the influence of preschool self-regulation on general and specific externalizing behavior problems in early elementary school and whether these relations were independent of associations between language, self-regulation, and externalizing behaviors in a sample of 815 children (44% female). Additionally, given a general pattern of sex differences in the presentations of externalizing behavior problems, self-regulation, and language skills, sex differences for these associations were examined. Results indicated unique relations of preschool self-regulation and language with both general externalizing behavior problems and specific problems of inattention. In general, self-regulation was a stronger longitudinal correlate of externalizing behavior for boys than it was for girls, and language was a stronger longitudinal predictor of hyperactive/impulsive behavior for girls than it was for boys.

  16. Problems with the Web Map Service Open GIS specification

    Directory of Open Access Journals (Sweden)

    Michal Šeliga

    2005-06-01

    Full Text Available The paper is not focused on the area of GeoWeb generally, because there is a lot of papers written on this topic (for examples: see the proceedings from the symposium GIS Ostrava (http://gis.vsb.cz the present. Author looks at the area from a different point of view. Is there anything wrong that comes with the Web Map Service (WMS specification? WMS (antl of course other specifications from the Open GIS Consortium (http://www.opengis.org brings new possibilities how to make GIS interoperable. The map server compatible with WMS specification publishes, upon a user request, the map as a raster (bitmap file that can be visualized by the user’s client. The bitmap can be filled up with pixels with some color values but there can be transparent pixels too. That’s why outputs from more than one map server in one map client (like in the digital cartography can be published. This possibility makes a big family of the data sources from the WMS servers that can be combined in many different ways. The user can obtain actual data from different sources and visualize them together. This advantage brings many disadvantages, which are described in the paper. There are problems with the symbology used. Data publishers can use so much different symbology (for example geologist, demographer, that the map server’s outputs should not be (quite often it is not possible eithn putted together. A more serious is a problem in the quality and temporal extent of the data. The user can combine the data with a different temporal extent and upon a visual comparison he can produce a wrong decision. For example, the harlot must be closed because there is a school in a distance less than 50 meters but the school is closed for more than two years and is used for the accommodation of the foreign workers. Another example: a school administration localised the school building with a precision to the street (it means to the centre of the street, but the school building is at

  17. On the precision of absolute sensitivity calibration and specifics of spectroscopic quantities interpretation in tokamaks

    Czech Academy of Sciences Publication Activity Database

    Naydenkova, Diana; Weinzettl, Vladimír; Stöckel, Jan; Matějíček, Jiří

    2014-01-01

    Roč. 53, č. 34 (2014), s. 8123-8130 ISSN 1559-128X R&D Projects: GA ČR(CZ) GA14-12837S Institutional support: RVO:61389021 Keywords : Spectroscopy * emission * spectrometers * absolute calibration Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.784, year: 2014 http://dx.doi.org/10.1364/AO.53.008123

  18. On the problem of linear calibration for a reading system of measuring devices

    International Nuclear Information System (INIS)

    Shigaev, V.N.

    1978-01-01

    The problem of gauging the frame of reference of a measuring device has been giVen a general approach which consists in finding an approximated inverse transformation on the basis of a partial diagram of a direct transformation which is defined on a given set, D, within the limits of the device measuring range. The following linear models of frame of reference are discussed: a general oblique system; a rectangular system with axes having different scales; a rectangular system with similar scale axes. Linear distortion for two rectangular models has been assessed. It is pointed out that the best approximation to the reduction operation should be found over the D set

  19. Specific problems in Kozloduy municipality, concerning NPP operation and decommissioning

    International Nuclear Information System (INIS)

    Pironkova, L.

    2000-01-01

    The only nuclear power plant in Bulgaria, which operates for 25 years is located in Kozloduy. Kozloduy municipality is situated in the northern part of Danube plane, includes the administrative center and four villages. It is 200 km far from Sofia and 80 km from the regional center Vratza. The Kozloduy NPP operates 6 units of total capacity 3760 MW, producing more than 40% of the electricity needs in Bulgaria. Settled and recurring problems of the municipality are related to economic, geographical, demographic and administration issues. Future problems will be related to forthcoming reactor shutdown and decommissioning. This involves economic problems, possible bankruptcies of local firms servicing the NPP, decreasing budget and living standard, expected restrictions of social programs, increasing unemployment, possible changes in demographic structure of population

  20. EMC Specific Problems of Frequency Converters Used at Interlocking Device

    Directory of Open Access Journals (Sweden)

    J. Novak

    2009-12-01

    Full Text Available The paper deals with problems of electromagnetic compatibility (EMC of frequency control drive of electromotive switch actuator of railway switch. The frequency converter with Pulse Width Modulation (PWM and the output sinus filter are used for feeding of the asynchronous motor of the switch actuator. This drive is operated in an insulated system of feeding voltages. The drive is fed by a frequency converter with an unshielded cable with length up to 1.2 km. The EMC problems occurring at development and operating of the drive are analyzed in this paper. The used solution of these problems and experience with EMC of the given system from real operation are described in this paper as well.

  1. Problems of increasing specific characteristics of pulse capacitors and cables

    International Nuclear Information System (INIS)

    Kuchinskij, G.S.; Monastyrskij, A.E.; Shilin, O.V.

    1984-01-01

    Requirements for high specific energy are practically related to all types of pulse capacitors of energy storage. At present the specific energy for most types of home and foreign pulse capacitors is about 0.1 MJ/m 3 at operating electric field intensity 70-100 kV/mm. It is shown that the basic means for increasing the specific energy and working intensity is the application of new polymeric film materials. Application of paper-film and film insulation permits to develop the specific types of capacitors designed for a limited service life in an aperiodic discharge mode with lower reliabiliy and the specific energy upto 0.5 MJ/m 3 . Characteristics of separate types of pulse capacitors and cables are given, and reliability criterion is considered. Measures of increasing reliability and service life for pulse capacitors and cables, used as tokamak power supplies are enumerated

  2. Exposure to lead and specific attentional problems in schoolchildren.

    NARCIS (Netherlands)

    Minder, B.; Das-Smaal, E.A.; Brand, E.F.J.M.; Orlebeke, J.F.

    1994-01-01

    A pilot study was carried out to investigate the relationship between exposure to lead and attention in children. The participants were 43 boys, 8 to 12 years of age, attending special schools for children with educational and/or learning problems (so called LOM schools). Children with probable

  3. Specific Reading Comprehension Disability: Major Problem, Myth, or Misnomer?

    Science.gov (United States)

    Spencer, Mercedes; Quinn, Jamie M.; Wagner, Richard K.

    2014-01-01

    The goal of the present study was to test three competing hypotheses about the nature of comprehension problems of students who are poor in reading comprehension. Participants in the study were first, second, and third graders, totaling nine cohorts and over 425,000 participants in all. The pattern of results was consistent across all cohorts:…

  4. Specific Reading Comprehension Disability: Major Problem, Myth, or Misnomer?

    OpenAIRE

    Spencer, Mercedes; Quinn, Jamie M.; Wagner, Richard K.

    2014-01-01

    The goal of the present study was to test three competing hypotheses about the nature of comprehension problems of students who are poor in reading comprehension. Participants in the study were first, second, and third graders, totaling 9 cohorts and over 425,000 participants in all. The pattern of results was consistent across all cohorts: Less than one percent of first- through third-grade students who scored as poor in reading comprehension were adequate in both decoding and vocabulary. Al...

  5. A calibration protocol for population-specific accelerometer cut-points in children.

    Science.gov (United States)

    Mackintosh, Kelly A; Fairclough, Stuart J; Stratton, Gareth; Ridgers, Nicola D

    2012-01-01

    To test a field-based protocol using intermittent activities representative of children's physical activity behaviours, to generate behaviourally valid, population-specific accelerometer cut-points for sedentary behaviour, moderate, and vigorous physical activity. Twenty-eight children (46% boys) aged 10-11 years wore a hip-mounted uniaxial GT1M ActiGraph and engaged in 6 activities representative of children's play. A validated direct observation protocol was used as the criterion measure of physical activity. Receiver Operating Characteristics (ROC) curve analyses were conducted with four semi-structured activities to determine the accelerometer cut-points. To examine classification differences, cut-points were cross-validated with free-play and DVD viewing activities. Cut-points of ≤ 372, >2160 and >4806 counts • min(-1) representing sedentary, moderate and vigorous intensity thresholds, respectively, provided the optimal balance between the related needs for sensitivity (accurately detecting activity) and specificity (limiting misclassification of the activity). Cross-validation data demonstrated that these values yielded the best overall kappa scores (0.97; 0.71; 0.62), and a high classification agreement (98.6%; 89.0%; 87.2%), respectively. Specificity values of 96-97% showed that the developed cut-points accurately detected physical activity, and sensitivity values (89-99%) indicated that minutes of activity were seldom incorrectly classified as inactivity. The development of an inexpensive and replicable field-based protocol to generate behaviourally valid and population-specific accelerometer cut-points may improve the classification of physical activity levels in children, which could enhance subsequent intervention and observational studies.

  6. A calibration protocol for population-specific accelerometer cut-points in children.

    Directory of Open Access Journals (Sweden)

    Kelly A Mackintosh

    Full Text Available To test a field-based protocol using intermittent activities representative of children's physical activity behaviours, to generate behaviourally valid, population-specific accelerometer cut-points for sedentary behaviour, moderate, and vigorous physical activity.Twenty-eight children (46% boys aged 10-11 years wore a hip-mounted uniaxial GT1M ActiGraph and engaged in 6 activities representative of children's play. A validated direct observation protocol was used as the criterion measure of physical activity. Receiver Operating Characteristics (ROC curve analyses were conducted with four semi-structured activities to determine the accelerometer cut-points. To examine classification differences, cut-points were cross-validated with free-play and DVD viewing activities.Cut-points of ≤ 372, >2160 and >4806 counts • min(-1 representing sedentary, moderate and vigorous intensity thresholds, respectively, provided the optimal balance between the related needs for sensitivity (accurately detecting activity and specificity (limiting misclassification of the activity. Cross-validation data demonstrated that these values yielded the best overall kappa scores (0.97; 0.71; 0.62, and a high classification agreement (98.6%; 89.0%; 87.2%, respectively. Specificity values of 96-97% showed that the developed cut-points accurately detected physical activity, and sensitivity values (89-99% indicated that minutes of activity were seldom incorrectly classified as inactivity.The development of an inexpensive and replicable field-based protocol to generate behaviourally valid and population-specific accelerometer cut-points may improve the classification of physical activity levels in children, which could enhance subsequent intervention and observational studies.

  7. Development of a problem solving evaluation instrument; untangling of specific problem solving assets

    Science.gov (United States)

    Adams, Wendy Kristine

    The purpose of my research was to produce a problem solving evaluation tool for physics. To do this it was necessary to gain a thorough understanding of how students solve problems. Although physics educators highly value problem solving and have put extensive effort into understanding successful problem solving, there is currently no efficient way to evaluate problem solving skill. Attempts have been made in the past; however, knowledge of the principles required to solve the subject problem are so absolutely critical that they completely overshadow any other skills students may use when solving a problem. The work presented here is unique because the evaluation tool removes the requirement that the student already have a grasp of physics concepts. It is also unique because I picked a wide range of people and picked a wide range of tasks for evaluation. This is an important design feature that helps make things emerge more clearly. This dissertation includes an extensive literature review of problem solving in physics, math, education and cognitive science as well as descriptions of studies involving student use of interactive computer simulations, the design and validation of a beliefs about physics survey and finally the design of the problem solving evaluation tool. I have successfully developed and validated a problem solving evaluation tool that identifies 44 separate assets (skills) necessary for solving problems. Rigorous validation studies, including work with an independent interviewer, show these assets identified by this content-free evaluation tool are the same assets that students use to solve problems in mechanics and quantum mechanics. Understanding this set of component assets will help teachers and researchers address problem solving within the classroom.

  8. [Transfusion and its specific problems in pediatrics and neonatology].

    Science.gov (United States)

    Pérel, Y; Runel, C; Huguenin, Y; Renesme, L; Aladjidi, N

    2017-09-01

    Principles of transfusion strategy have been used for neonates and children similar to adults. However, due to substantial discrepancies between physiology/pathology in children and in their adult counterparts, decisions, indications, and doses are different from those of adults, especially in neonates. Specific data and practice guidelines for blood product transfusion are reported owing to the experience of pediatrics and neonatology units and partners of the French Blood product bank. Copyright © 2017. Published by Elsevier SAS.

  9. Instrumentation report 1: specification, design, calibration, and installation of instrumentation for an experimental, high-level, nuclear waste storage facility

    International Nuclear Information System (INIS)

    Brough, W.G.; Patrick, W.C.

    1982-01-01

    The Spent Fuel Test-Climax (SFT-C) is being conducted 420 m underground at the Nevada Test Site under the auspices of the US Department of Energy. The test facility houses 11 spent fuel assemblies from an operating commercial nuclear reactor and numerous other thermal sources used to simulate the near-field effects of a large repository. We developed a large-scale instrumentation plan to ensure that a sufficient quality and quantity of data were acquired during the three- to five-year test. These data help satisfy scientific, operational, and radiation safety objectives. Over 800 data channels are being scanned to measure temperature, electrical power, radiation, air flow, dew point, stress, displacement, and equipment operation status (on/off). This document details the criteria, design, specifications, installation, calibration, and current performance of the entire instrumentation package

  10. General problems specific to hot nuclear materials research facilities

    International Nuclear Information System (INIS)

    Bart, G.

    1996-01-01

    During the sixties, governments have installed hot nuclear materials research facilities to characterize highly radioactive materials, to describe their in-pile behaviour, to develop and test new reactor core components, and to provide the industry with radioisotopes. Since then, the attitude towards the nuclear option has drastically changed and resources have become very tight. Within the changed political environment, the national research centres have defined new objectives. Given budgetary constraints, nuclear facilities have to co-operate internationally and to look for third party research assignments. The paper discusses the problems and needs within experimental nuclear research facilities as well as industrial requirements. Special emphasis is on cultural topics (definition of the scope of nuclear research facilities, the search for competitive advantages, and operational requirements), social aspects (overageing of personnel, recruitment, and training of new staff), safety related administrative and technical issues, and research needs for expertise and state of the art analytical infrastructure

  11. [Specific problems posed by carbohydrate utilization in the rainbow trout].

    Science.gov (United States)

    Bergot, F

    1979-01-01

    Carbohydrate incorporation in trout diets arises problems both at digestive and metabolic levels. Digestive utilization of carbohydrate closely depends on their molecular weight. In addition, in the case of complex carbohydrates (starches), different factors such as the level of incorporation, the amount consumed and the physical state of starch influence the digestibility. The measurement of digestibility in itself is confronted with methodological difficulties. The way the feces are collected can affect the digestion coefficient. Dietary carbohydrates actually serve as a source of energy. Nevertheless, above a certain level in the diet, intolerance phenomena may appear. The question that arises now is to establish the optimal part that carbohydrates can take in the metabolizable energy of a given diet.

  12. Specific problems concerning aircraft impact on nuclear containment vessels

    International Nuclear Information System (INIS)

    Fuzier, J.P.; Cheyrezy, M.H.; Dufour, C.J.

    1977-01-01

    Due to the high population density, in Belgium PWR power plants are designed against aircraft impacts (BOEING 707 crashing at 360 km per hour and STARFIGHTER F 104 G crashing at 540 km per hour). A double wall is used for the containment shield. The lack of relevant data and specifications for such a loading on the non-prestressed external wall led the authors to determine the suitable safety criteria, the most appropriate materials to be used and the corresponding limit state design through dynamic and plastic analysis. (Auth.)

  13. Failure of homologous synapsis and sex-specific reproduction problems

    Directory of Open Access Journals (Sweden)

    Hiroki eKurahashi

    2012-06-01

    Full Text Available The prophase of meiosis I ensures the correct segregation of chromosomes to each daughter cell. This includes the pairing, synapsis and recombination of homologous chromosomes. A subset of chromosomal abnormalities, including translocation and inversion, disturbs these processes, resulting in the failure to complete synapsis. This activates the meiotic pachytene checkpoint, and the gametes are fated to undergo cell cycle arrest and subsequent apoptosis. Spermatogenic cells appear to be more vulnerable to the pachytene checkpoint, and male carriers of chromosomal abnormalities are more susceptible to infertility. In contrast, oocytes tend to bypass the checkpoint and instead generate other problems, such as chromosome imbalance that often leads to recurrent pregnancy loss in female carriers. Recent advances in genetic manipulation technologies have increased our knowledge about the pachytene checkpoint and surveillance systems that detect chromosomal synapsis. This review focuses on the consequences of synapsis failure in humans and provides an overview of the mechanisms involved. We also discuss the sexual dimorphism of the involved pathways that leads to the differences in reproductive outcomes between males and females.

  14. Calibration of germanium detectors

    International Nuclear Information System (INIS)

    Bjurman, B.; Erlandsson, B.

    1985-01-01

    This paper describes problems concerning the calibration of germanium detectors for the measurement of gamma-radiation from environmental samples. It also contains a brief description of some ways of reducing the uncertainties concerning the activity determination. These uncertainties have many sources, such as counting statistics, full energy peak efficiency determination, density correction and radionuclide specific-coincidence effects, when environmental samples are investigated at close source-to-detector distances

  15. Synthesis Polarimetry Calibration

    Science.gov (United States)

    Moellenbrock, George

    2017-10-01

    Synthesis instrumental polarization calibration fundamentals for both linear (ALMA) and circular (EVLA) feed bases are reviewed, with special attention to the calibration heuristics supported in CASA. Practical problems affecting modern instruments are also discussed.

  16. Ethnic variability in body size, proportions and composition in children aged 5 to 11 years: is ethnic-specific calibration of bioelectrical impedance required?

    Directory of Open Access Journals (Sweden)

    Simon Lee

    Full Text Available Bioelectrical Impedance Analysis (BIA has the potential to be used widely as a method of assessing body fatness and composition, both in clinical and community settings. BIA provides bioelectrical properties, such as whole-body impedance which ideally needs to be calibrated against a gold-standard method in order to provide accurate estimates of fat-free mass. UK studies in older children and adolescents have shown that, when used in multi-ethnic populations, calibration equations need to include ethnic-specific terms, but whether this holds true for younger children remains to be elucidated. The aims of this study were to examine ethnic differences in body size, proportions and composition in children aged 5 to 11 years, and to establish the extent to which such differences could influence BIA calibration.In a multi-ethnic population of 2171 London primary school-children (47% boys; 34% White, 29% Black African/Caribbean, 25% South Asian, 12% Other detailed anthropometric measurements were performed and ethnic differences in body size and proportion were assessed. Ethnic differences in fat-free mass, derived by deuterium dilution, were further evaluated in a subsample of the population (n = 698. Multiple linear regression models were used to calibrate BIA against deuterium dilution.In children < 11 years of age, Black African/Caribbean children were significantly taller, heavier and had larger body size than children of other ethnicities. They also had larger waist and limb girths and relatively longer legs. Despite these differences, ethnic-specific terms did not contribute significantly to the BIA calibration equation (Fat-free mass = 1.12+0.71*(height2/impedance+0.18*weight.Although clear ethnic differences in body size, proportions and composition were evident in this population of young children aged 5 to 11 years, an ethnic-specific BIA calibration equation was not required.

  17. An episodic specificity induction enhances means-end problem solving in young and older adults.

    Science.gov (United States)

    Madore, Kevin P; Schacter, Daniel L

    2014-12-01

    Episodic memory plays an important role not only in remembering past experiences, but also in constructing simulations of future experiences and solving means-end social problems. We recently found that an episodic specificity induction-brief training in recollecting details of past experiences-enhances performance of young and older adults on memory and imagination tasks. Here we tested the hypothesis that this specificity induction would also positively impact a means-end problem-solving task on which age-related changes have been linked to impaired episodic memory. Young and older adults received the specificity induction or a control induction before completing a means-end problem-solving task, as well as memory and imagination tasks. Consistent with previous findings, older adults provided fewer relevant steps on problem solving than did young adults, and their responses also contained fewer internal (i.e., episodic) details across the 3 tasks. There was no difference in the number of other (e.g., irrelevant) steps on problem solving or external (i.e., semantic) details generated on the 3 tasks as a function of age. Critically, the specificity induction increased the number of relevant steps and internal details (but not other steps or external details) that both young and older adults generated in problem solving compared with the control induction, as well as the number of internal details (but not external details) generated for memory and imagination. Our findings support the idea that episodic retrieval processes are involved in means-end problem solving, extend the range of tasks on which a specificity induction targets these processes, and show that the problem-solving performance of older adults can benefit from a specificity induction as much as that of young adults. (PsycINFO Database Record (c) 2014 APA, all rights reserved).

  18. Specific and social fears in children and adolescents: separating normative fears from problem indicators and phobias.

    Science.gov (United States)

    Laporte, Paola P; Pan, Pedro M; Hoffmann, Mauricio S; Wakschlag, Lauren S; Rohde, Luis A; Miguel, Euripedes C; Pine, Daniel S; Manfro, Gisele G; Salum, Giovanni A

    2017-01-01

    To distinguish normative fears from problematic fears and phobias. We investigated 2,512 children and adolescents from a large community school-based study, the High Risk Study for Psychiatric Disorders. Parent reports of 18 fears and psychiatric diagnosis were investigated. We used two analytical approaches: confirmatory factor analysis (CFA)/item response theory (IRT) and nonparametric receiver operating characteristic (ROC) curve. According to IRT and ROC analyses, social fears are more likely to indicate problems and phobias than specific fears. Most specific fears were normative when mild; all specific fears indicate problems when pervasive. In addition, the situational fear of toilets and people who look unusual were highly indicative of specific phobia. Among social fears, those not restricted to performance and fear of writing in front of others indicate problems when mild. All social fears indicate problems and are highly indicative of social phobia when pervasive. These preliminary findings provide guidance for clinicians and researchers to determine the boundaries that separate normative fears from problem indicators in children and adolescents, and indicate a differential severity threshold for specific and social fears.

  19. Specific and social fears in children and adolescents: separating normative fears from problem indicators and phobias

    Directory of Open Access Journals (Sweden)

    Paola P. Laporte

    2017-03-01

    Full Text Available Objective: To distinguish normative fears from problematic fears and phobias. Methods: We investigated 2,512 children and adolescents from a large community school-based study, the High Risk Study for Psychiatric Disorders. Parent reports of 18 fears and psychiatric diagnosis were investigated. We used two analytical approaches: confirmatory factor analysis (CFA/item response theory (IRT and nonparametric receiver operating characteristic (ROC curve. Results: According to IRT and ROC analyses, social fears are more likely to indicate problems and phobias than specific fears. Most specific fears were normative when mild; all specific fears indicate problems when pervasive. In addition, the situational fear of toilets and people who look unusual were highly indicative of specific phobia. Among social fears, those not restricted to performance and fear of writing in front of others indicate problems when mild. All social fears indicate problems and are highly indicative of social phobia when pervasive. Conclusion: These preliminary findings provide guidance for clinicians and researchers to determine the boundaries that separate normative fears from problem indicators in children and adolescents, and indicate a differential severity threshold for specific and social fears.

  20. Two combinatorial optimization problems for SNP discovery using base-specific cleavage and mass spectrometry.

    Science.gov (United States)

    Chen, Xin; Wu, Qiong; Sun, Ruimin; Zhang, Louxin

    2012-01-01

    The discovery of single-nucleotide polymorphisms (SNPs) has important implications in a variety of genetic studies on human diseases and biological functions. One valuable approach proposed for SNP discovery is based on base-specific cleavage and mass spectrometry. However, it is still very challenging to achieve the full potential of this SNP discovery approach. In this study, we formulate two new combinatorial optimization problems. While both problems are aimed at reconstructing the sample sequence that would attain the minimum number of SNPs, they search over different candidate sequence spaces. The first problem, denoted as SNP - MSP, limits its search to sequences whose in silico predicted mass spectra have all their signals contained in the measured mass spectra. In contrast, the second problem, denoted as SNP - MSQ, limits its search to sequences whose in silico predicted mass spectra instead contain all the signals of the measured mass spectra. We present an exact dynamic programming algorithm for solving the SNP - MSP problem and also show that the SNP - MSQ problem is NP-hard by a reduction from a restricted variation of the 3-partition problem. We believe that an efficient solution to either problem above could offer a seamless integration of information in four complementary base-specific cleavage reactions, thereby improving the capability of the underlying biotechnology for sensitive and accurate SNP discovery.

  1. Problems related to the use of annihilation radiation for precision energy calibration of Ge(Li) detectors

    International Nuclear Information System (INIS)

    Fransson, K.; Nilsson, A.; Raedt, J. de; Rensfelt, K.G.

    1976-03-01

    The energy of positron annihilation radiation emanating from several materials was measured, using recently established energies of the 198 Au and 192 Ir γ-rays for calibration. Corrections for the binding energy of positrons and electrons were applied. A peak fitting routine was used which took into account both the background step under the peak, and the possibility that only a part of the detector contains charge-carrier traps. The electron rest mass energy (corrected for binding energies) could be reproduced to within +- 10 eV, in some well-behaved metals even to within +- 5 eV. (Auth.)

  2. A study and meta-analysis of lay attributions of cures for overcoming specific psychological problems.

    Science.gov (United States)

    Furnham, A; Hayward, R

    1997-09-01

    Lay beliefs about the importance of 24 different contributors to overcoming 4 disorders that constitute primarily cognitive deficits were studied. A meta-analysis of previous programmatic studies in the area was performed so that 22 different psychological problems could be compared. In the present study, 107 participants completed a questionnaire indicating how effective 24 factors were in overcoming 4 specific problems: dyslexia, fear of flying, amnesia, and learning difficulties. Factor analysis revealed almost identical clusters (inner control, social consequences, understanding, receiving help, and fate) for each problem. The perceived relevance of those factors differed significantly between problems. Some individual difference factors (sex and religion) were found to predict certain factor attributions for specific disorders. A meta-analysis of the 5 studies in this series yielded a 6-factor structure comparable to those of the individual studies and provided results indicating the benefits and limitations of this kind of investigation. The clinical relevance of studying attributions for cure is considered.

  3. TH-C-BRD-05: Reducing Proton Beam Range Uncertainty with Patient-Specific CT HU to RSP Calibrations Based On Single-Detector Proton Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Doolan, P [University College London, London (United Kingdom); Massachusetts General Hospital, Boston, MA (United States); Sharp, G; Testa, M; Lu, H-M [Massachusetts General Hospital, Boston, MA (United States); Bentefour, E [Ion Beam Applications (IBA), Louvain la Neuve (Belgium); Royle, G [University College London, London (United Kingdom)

    2014-06-15

    Purpose: Beam range uncertainty in proton treatment comes primarily from converting the patient's X-ray CT (xCT) dataset to relative stopping power (RSP). Current practices use a single curve for this conversion, produced by a stoichiometric calibration based on tissue composition data for average, healthy, adult humans, but not for the individual in question. Proton radiographs produce water-equivalent path length (WEPL) maps, dependent on the RSP of tissues within the specific patient. This work investigates the use of such WEPL maps to optimize patient-specific calibration curves for reducing beam range uncertainty. Methods: The optimization procedure works on the principle of minimizing the difference between the known WEPL map, obtained from a proton radiograph, and a digitally-reconstructed WEPL map (DRWM) through an RSP dataset, by altering the calibration curve that is used to convert the xCT into an RSP dataset. DRWMs were produced with Plastimatch, an in-house developed software, and an optimization procedure was implemented in Matlab. Tests were made on a range of systems including simulated datasets with computed WEPL maps and phantoms (anthropomorphic and real biological tissue) with WEPL maps measured by single detector proton radiography. Results: For the simulated datasets, the optimizer showed excellent results. It was able to either completely eradicate or significantly reduce the root-mean-square-error (RMSE) in the WEPL for the homogeneous phantoms (to zero for individual materials or from 1.5% to 0.2% for the simultaneous optimization of multiple materials). For the heterogeneous phantom the RMSE was reduced from 1.9% to 0.3%. Conclusion: An optimization procedure has been designed to produce patient-specific calibration curves. Test results on a range of systems with different complexities and sizes have been promising for accurate beam range control in patients. This project was funded equally by the Engineering and Physical Sciences

  4. Behavior problems and social competence in Brazilian children with specific language impairment

    Directory of Open Access Journals (Sweden)

    Marina Leite Puglisi

    2016-01-01

    Full Text Available Abstract This study aimed to investigate the behavior and social profile of Brazilian children with specific language impairment (SLI and explore whether the severity of language deficits was associated with behavioral problems and low social competence. Twenty-four children with SLI aged from 6 to 11 years who showed substantial expressive language problems and were receiving speech-language therapy were assessed through the Child Behavior Checklist (CBCL. Children with SLI showed high rates of behavioral problems and low levels of social competence. With the exception of two subscales (“somatic” and “rule breaker”, the percentage of children with SLI at risk of behavioral problems was significantly higher than the same proportion in the general population; and almost all children with SLI (95.2 % demonstrated problems with social competence. The severity of language deficits was associated with the risk of behavioral problems according to only one criterion. No associations were found between the severity of language problems and social competence. The study provides cross-cultural evidence to support the existence of behavior problems and reduced social competence in children with SLI. Our findings point to the need of using a combination of measures to classify the severity of language problems rather than a single dimension.

  5. Region-specific study of the electric utility industry: problem identification, analysis, and recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Pochan, M.J.

    1985-07-01

    A number of problems were identified that could stand in the way of maintaining an adequate, reliable and economic supply of electric power for the United States in the future. The problems were analyzed by studying a specific region, VACAR (Virginia-Carolinas), in some detail. It was concluded that the future power supply is in jeopardy, but that drastic changes in the present system of investor-owned utilities, specifically, deregulation or government ownership, were not justified. It was recommended that the present electric system be modified and strengthened to meet future needs. 2 refs., 8 figs., 15 tabs.

  6. Region-specific study of the electric utility industry: problem identification, analysis, and recommendations

    International Nuclear Information System (INIS)

    Pochan, M.J.

    1985-07-01

    A number of problems were identified that could stand in the way of maintaining an adequate, reliable and economic supply of electric power for the United States in the future. The problems were analyzed by studying a specific region, VACAR (Virginia-Carolinas), in some detail. It was concluded that the future power supply is in jeopardy, but that drastic changes in the present system of investor-owned utilities, specifically, deregulation or government ownership, were not justified. It was recommended that the present electric system be modified and strengthened to meet future needs. 2 refs., 8 figs., 15 tabs

  7. Determination of the thermal conductivity and specific heat capacity of neem seeds by inverse problem method

    Directory of Open Access Journals (Sweden)

    S.N. Nnamchi

    2010-01-01

    Full Text Available Determination of the thermal conductivity and the specific heat capacity of neem seeds (Azadirachta indica A. Juss usingthe inverse method is the main subject of this work. One-dimensional formulation of heat conduction problem in a spherewas used. Finite difference method was adopted for the solution of the heat conduction problem. The thermal conductivityand the specific heat capacity were determined by least square method in conjunction with Levenberg-Marquardt algorithm.The results obtained compare favourably with those obtained experimentally. These results are useful in the analysis ofneem seeds drying and leaching processes.

  8. Maternal anxiety versus depressive disorders: specific relations to infants' crying, feeding and sleeping problems.

    Science.gov (United States)

    Petzoldt, J; Wittchen, H-U; Einsle, F; Martini, J

    2016-03-01

    Maternal depression has been associated with excessive infant crying, feeding and sleeping problems, but the specificity of maternal depression, as compared with maternal anxiety remains unclear and manifest disorders prior to pregnancy have been widely neglected. In this prospective longitudinal study, the specific associations of maternal anxiety and depressive disorders prior to, during and after pregnancy and infants' crying, feeding and sleeping problems were investigated in the context of maternal parity. In the Maternal Anxiety in Relation to Infant Development (MARI) Study, n = 306 primiparous and multiparous women were repeatedly interviewed from early pregnancy until 16 months post partum with the Composite International Diagnostic Interview for Women (CIDI-V) to assess DSM-IV anxiety and depressive disorders. Information on excessive infant crying, feeding and sleeping problems was obtained from n = 286 mothers during postpartum period via questionnaire and interview (Baby-DIPS). Findings from this study revealed syndrome-specific risk constellations for maternal anxiety and depressive disorders as early as prior to pregnancy: Excessive infant crying (10.1%) was specifically associated with maternal anxiety disorders, especially in infants of younger and lower educated first-time mothers. Feeding problems (36.4%) were predicted by maternal anxiety (and comorbid depressive) disorders in primiparous mothers and infants with lower birth weight. Infant sleeping problems (12.2%) were related to maternal depressive (and comorbid anxiety) disorders irrespective of maternal parity. Primiparous mothers with anxiety disorders may be more prone to anxious misinterpretations of crying and feeding situations leading to an escalation of mother-infant interactions. The relation between maternal depressive and infant sleeping problems may be better explained by a transmission of unsettled maternal sleep to the fetus during pregnancy or a lack of daily

  9. Topics in Statistical Calibration

    Science.gov (United States)

    2014-03-27

    Natural cubic spline speed di st 110 B.2 The calibrate function The most basic calibration problem, the one often encountered in more advanced ...0040-1706, 1537-2723. A. M. Mood, F. A. Graybill, and D. C. Boes. Introduction to the Theory of Statistics. McGraw-Hill, Auckland , U.A, 1974. ISBN

  10. Body composition in Nepalese children using isotope dilution: the production of ethnic-specific calibration equations and an exploration of methodological issues.

    Science.gov (United States)

    Devakumar, Delan; Grijalva-Eternod, Carlos S; Roberts, Sebastian; Chaube, Shiva Shankar; Saville, Naomi M; Manandhar, Dharma S; Costello, Anthony; Osrin, David; Wells, Jonathan C K

    2015-01-01

    Background. Body composition is important as a marker of both current and future health. Bioelectrical impedance (BIA) is a simple and accurate method for estimating body composition, but requires population-specific calibration equations. Objectives. (1) To generate population specific calibration equations to predict lean mass (LM) from BIA in Nepalese children aged 7-9 years. (2) To explore methodological changes that may extend the range and improve accuracy. Methods. BIA measurements were obtained from 102 Nepalese children (52 girls) using the Tanita BC-418. Isotope dilution with deuterium oxide was used to measure total body water and to estimate LM. Prediction equations for estimating LM from BIA data were developed using linear regression, and estimates were compared with those obtained from the Tanita system. We assessed the effects of flexing the arms of children to extend the range of coverage towards lower weights. We also estimated potential error if the number of children included in the study was reduced. Findings. Prediction equations were generated, incorporating height, impedance index, weight and sex as predictors (R (2) 93%). The Tanita system tended to under-estimate LM, with a mean error of 2.2%, but extending up to 25.8%. Flexing the arms to 90° increased the lower weight range, but produced a small error that was not significant when applied to children <16 kg (p 0.42). Reducing the number of children increased the error at the tails of the weight distribution. Conclusions. Population-specific isotope calibration of BIA for Nepalese children has high accuracy. Arm position is important and can be used to extend the range of low weight covered. Smaller samples reduce resource requirements, but leads to large errors at the tails of the weight distribution.

  11. Body composition in Nepalese children using isotope dilution: the production of ethnic-specific calibration equations and an exploration of methodological issues

    Directory of Open Access Journals (Sweden)

    Delan Devakumar

    2015-03-01

    Full Text Available Background. Body composition is important as a marker of both current and future health. Bioelectrical impedance (BIA is a simple and accurate method for estimating body composition, but requires population-specific calibration equations.Objectives. (1 To generate population specific calibration equations to predict lean mass (LM from BIA in Nepalese children aged 7–9 years. (2 To explore methodological changes that may extend the range and improve accuracy.Methods. BIA measurements were obtained from 102 Nepalese children (52 girls using the Tanita BC-418. Isotope dilution with deuterium oxide was used to measure total body water and to estimate LM. Prediction equations for estimating LM from BIA data were developed using linear regression, and estimates were compared with those obtained from the Tanita system. We assessed the effects of flexing the arms of children to extend the range of coverage towards lower weights. We also estimated potential error if the number of children included in the study was reduced.Findings. Prediction equations were generated, incorporating height, impedance index, weight and sex as predictors (R2 93%. The Tanita system tended to under-estimate LM, with a mean error of 2.2%, but extending up to 25.8%. Flexing the arms to 90° increased the lower weight range, but produced a small error that was not significant when applied to children <16 kg (p 0.42. Reducing the number of children increased the error at the tails of the weight distribution.Conclusions. Population-specific isotope calibration of BIA for Nepalese children has high accuracy. Arm position is important and can be used to extend the range of low weight covered. Smaller samples reduce resource requirements, but leads to large errors at the tails of the weight distribution.

  12. Calibration of a Plant Uptake Model with Plant- and Site-Specific. Data for Uptake of Chlorinated Organic Compounds into Radish

    DEFF Research Database (Denmark)

    Trapp, Stefan

    2015-01-01

    The uptake of organic pollutants by plants is an important process for the exposure of humans to toxic chemicals. The objective of this study was to calibrate the parameters of a common plant uptake model by comparison to experimental results from literature. Radish was grown in contaminated soil...... with default data and site-specific data were similar. Deposition from air was the major uptake mechanism into shoots. Transport from soil with resuspended particles was only relevant for the contaminated plot. The calculation results (in dry weight) were most sensitive to changes of the water content of plant...

  13. Self consistently calibrated photopyroelectric calorimeter for the high resolution simultaneous absolute measurement of the specific heat and of the thermal conductivity

    Directory of Open Access Journals (Sweden)

    U. Zammit

    2012-03-01

    Full Text Available High temperature resolution study of the specific heat and of the thermal conductivity over the smecticA-nematic and nematic-isotropic phase transitions in octylcynobephenyl liquid crystal using a new photopyroelectric calorimetry configuration are reported, where, unlike previously adopted ones, no calibration is required other than the procedure used during the actual measurement. This makes photopyroelectric calorimetry suitable for “absolute” measurements of the thermal parameters like most other existing conventional calorimetric techniques where, however, the thermal conductivity cannot be measured.

  14. Importance of material matching in the calibration of asymmetric flow field-flow fractionation: material specificity and nanoparticle surface coating effects on retention time

    Energy Technology Data Exchange (ETDEWEB)

    Qu, Haiou [U.S. Food and Drug Administration, Office of Regulatory Affairs, Arkansas Regional Laboratory (United States); Quevedo, Ivan R. [Universidad Iberoamericana, Departamento de Ingeniería y Ciencias Químicas (Mexico); Linder, Sean W.; Fong, Andrew; Mudalige, Thilak K., E-mail: Thilak.Mudalige@fda.hhs.gov [U.S. Food and Drug Administration, Office of Regulatory Affairs, Arkansas Regional Laboratory (United States)

    2016-10-15

    Asymmetric flow field-flow fractionation (AF4) coupled with dynamic light scattering or multiangle light scattering detectors is a promising technique for the size-based separation of colloidal particles (nano- and submicron scale) and the online determination of the particle size of the separated fractions in aqueous suspensions. In most cases, the applications of these detectors are problematic due to the material-specific properties of the analyte that results in erroneous calculations, and as an alternative, different nanoparticle size standards are required to properly calibrate the size-based retention in AF4. The availability of nanoparticle size standards in different materials is limited, and this deviation from ideal conditions of retention is mainly due to material-specific and particle coating-specific membrane–particle interactions. Here, we present an experimental method on the applicability of polystyrene nanoparticles (PS NP) as standard for AF4 calibration and compare with gold nanoparticle (Au NP) standards having different nominal sizes and surface functionalities.

  15. Importance of material matching in the calibration of asymmetric flow field-flow fractionation: material specificity and nanoparticle surface coating effects on retention time

    International Nuclear Information System (INIS)

    Qu, Haiou; Quevedo, Ivan R.; Linder, Sean W.; Fong, Andrew; Mudalige, Thilak K.

    2016-01-01

    Asymmetric flow field-flow fractionation (AF4) coupled with dynamic light scattering or multiangle light scattering detectors is a promising technique for the size-based separation of colloidal particles (nano- and submicron scale) and the online determination of the particle size of the separated fractions in aqueous suspensions. In most cases, the applications of these detectors are problematic due to the material-specific properties of the analyte that results in erroneous calculations, and as an alternative, different nanoparticle size standards are required to properly calibrate the size-based retention in AF4. The availability of nanoparticle size standards in different materials is limited, and this deviation from ideal conditions of retention is mainly due to material-specific and particle coating-specific membrane–particle interactions. Here, we present an experimental method on the applicability of polystyrene nanoparticles (PS NP) as standard for AF4 calibration and compare with gold nanoparticle (Au NP) standards having different nominal sizes and surface functionalities.

  16. SCIAMACHY Level 1 data: calibration concept and in-flight calibration

    Science.gov (United States)

    Lichtenberg, G.; Kleipool, Q.; Krijger, J. M.; van Soest, G.; van Hees, R.; Tilstra, L. G.; Acarreta, J. R.; Aben, I.; Ahlers, B.; Bovensmann, H.; Chance, K.; Gloudemans, A. M. S.; Hoogeveen, R. W. M.; Jongma, R. T. N.; Noël, S.; Piters, A.; Schrijver, H.; Schrijvers, C.; Sioris, C. E.; Skupin, J.; Slijkhuis, S.; Stammes, P.; Wuttke, M.

    2006-11-01

    The calibration of SCIAMACHY was thoroughly checked since the instrument was launched on-board ENVISAT in February 2002. While SCIAMACHY's functional performance is excellent since launch, a number of technical difficulties have appeared, that required adjustments to the calibration. The problems can be separated into three types: (1) Those caused by the instrument and/or platform environment. Among these are the high water content in the satellite structure and/or MLI layer. This results in the deposition of ice on the detectors in channels 7 and 8 which seriously affects the retrievals in the IR, mostly because of the continuous change of the slit function caused by scattering of the light through the ice layer. Additionally a light leak in channel 7 severely hampers any retrieval from this channel. (2) Problems due to errors in the on-ground calibration and/or data processing affecting for example the radiometric calibration. A new approach based on a mixture of on-ground and in-flight data is shortly described here. (3) Problems caused by principal limitations of the calibration concept, e.g. the possible appearance of spectral structures after the polarisation correction due to unavoidable errors in the determination of atmospheric polarisation. In this paper we give a complete overview of the calibration and problems that still have to be solved. We will also give an indication of the effect of calibration problems on retrievals where possible. Since the operational processing chain is currently being updated and no newly processed data are available at this point in time, for some calibration issues only a rough estimate of the effect on Level 2 products can be given. However, it is the intention of this paper to serve as a future reference for detailed studies into specific calibration issues.

  17. Worrying about the future: An episodic specificity induction impacts problem solving, reappraisal, and well-being.

    Science.gov (United States)

    Jing, Helen G; Madore, Kevin P; Schacter, Daniel L

    2016-04-01

    Previous research has demonstrated that an episodic specificity induction--brief training in recollecting details of a recent experience--enhances performance on various subsequent tasks thought to draw upon episodic memory processes. Existing work has also shown that mental simulation can be beneficial for emotion regulation and coping with stressors. Here we focus on understanding how episodic detail can affect problem solving, reappraisal, and psychological well-being regarding worrisome future events. In Experiment 1, an episodic specificity induction significantly improved participants' performance on a subsequent means-end problem solving task (i.e., more relevant steps) and an episodic reappraisal task (i.e., more episodic details) involving personally worrisome future events compared with a control induction not focused on episodic specificity. Imagining constructive behaviors with increased episodic detail via the specificity induction was also related to significantly larger decreases in anxiety, perceived likelihood of a bad outcome, and perceived difficulty to cope with a bad outcome, as well as larger increases in perceived likelihood of a good outcome and indicated use of active coping behaviors compared with the control. In Experiment 2, we extended these findings using a more stringent control induction, and found preliminary evidence that the specificity induction was related to an increase in positive affect and decrease in negative affect compared with the control. Our findings support the idea that episodic memory processes are involved in means-end problem solving and episodic reappraisal, and that increasing the episodic specificity of imagining constructive behaviors regarding worrisome events may be related to improved psychological well-being. (c) 2016 APA, all rights reserved).

  18. Calibration of Flick standards

    International Nuclear Information System (INIS)

    Thalmann, Ruedi; Spiller, Jürg; Küng, Alain; Jusko, Otto

    2012-01-01

    Flick standards or magnification standards are widely used for an efficient and functional calibration of the sensitivity of form measuring instruments. The results of a recent measurement comparison have shown to be partially unsatisfactory and revealed problems related to the calibration of these standards. In this paper the influence factors for the calibration of Flick standards using roundness measurement instruments are discussed in detail, in particular the bandwidth of the measurement chain, residual form errors of the device under test, profile distortions due to the diameter of the probing element and questions related to the definition of the measurand. The different contributions are estimated using simulations and are experimentally verified. Also alternative methods to calibrate Flick standards are investigated. Finally the practical limitations of Flick standard calibration are shown and the usability of Flick standards both to calibrate the sensitivity of roundness instruments and to check the filter function of such instruments is analysed. (paper)

  19. ACCOUNTING TREATMENTS ON FORESTRY SPECIAL FUNDS AND SPECIFIC PROBLEMS IN ROMANIA

    Directory of Open Access Journals (Sweden)

    Hada Teodor

    2013-07-01

    Full Text Available This study, theoretically and practically, presents the accounting system for forestry special purpose funds in Romania. In addition, the main problems Romanian forestry faces nowadays are highlighted in the content, given the legislative changes expected in the near future. Accounting treatments specific to Romanian forestry regarding special funds, namely the conservation and regeneration fund, the accessibility fund, the environmental fund and the improvement fund are governed in the current law, mainly by the Forestry Code in Romania - Law 46/2008 supplemented by other specialized works used within the National Forest Directorate in Romania. Among the specific forestry regulations, special purpose funds are an area of interest in the current economic crisis being presented under several aspects: establishing the Fund, its utility and calculation method, its recording into accounting, or its specific tax implications. The main objective of this paper is to provide both a framework for analysis and presentation of the problems faced by forestry activity in Romania, and the accounting treatments specific to forestry activities, by illustrating the main entries made through financial and accounting documents. Given that we fully realize the environment’s importance in our lives, we understand the very close relationship between the forestry business’ enactment, its financing and its supervision. Special funds are the basis for financing forestry projects. Their study covers a gap in the specialized literature, providing specialists, practitioners and other stakeholders a framework. In the current economic and political context, the forestry problems, environmental issues in general are perceived to be more stringent. The solutions identified as a firm response to the existing problems are therefore of major importance, of which, in this study, we have identified and proposed several solutions. Practical examples have as grounds real data

  20. ACCOUNTING TREATMENTS ON FORESTRY SPECIAL FUNDS AND SPECIFIC PROBLEMS IN ROMANIA

    OpenAIRE

    Hada Teodor; Mărginean Radu

    2013-01-01

    This study, theoretically and practically, presents the accounting system for forestry special purpose funds in Romania. In addition, the main problems Romanian forestry faces nowadays are highlighted in the content, given the legislative changes expected in the near future. Accounting treatments specific to Romanian forestry regarding special funds, namely the conservation and regeneration fund, the accessibility fund, the environmental fund and the improvement fund are governed in the curre...

  1. Mental Health Problems during Puberty: Tanner Stage-Related Differences in Specific Symptoms. The TRAILS Study

    Science.gov (United States)

    Oldehinkel, Albertine J.; Verhulst, Frank C.; Ormel, Johan

    2011-01-01

    The aim of this study was to investigate associations between specific mental health problems and pubertal stage in (pre)adolescents participating in the Dutch prospective cohort study TRAILS (first assessment: N = 2230, age 11.09 [plus or minus] 0.56, 50.8% girls; second assessment: N = 2149, age 13.56 [plus or minus] 0.53, 51.0% girls). Mental…

  2. A problem of optimization for the specific cost of installed electric power in nuclear plants

    Energy Technology Data Exchange (ETDEWEB)

    Sultan, M A; Khattab, M S [Reactors Dept. nuclear research centre, atomic energy authority, Cairo, (Egypt)

    1995-10-01

    The optimization problem analyzed in this paper is related to the thermal cycle parameters in nuclear power stations having steam generators. The optimization the specific cost of installed power with respect to the average operating saturation temperature in the station thermal cycle. The analysis considers the maximum fuel cladding temperature as a limiting factor in the optimization process as it is related to the safe operation of the reactor. 4 figs.

  3. Stress moderates the relationships between problem-gambling severity and specific psychopathologies.

    Science.gov (United States)

    Ronzitti, Silvia; Kraus, Shane W; Hoff, Rani A; Potenza, Marc N

    2018-01-01

    The purpose of this study was to examine the extent to which stress moderated the relationships between problem-gambling severity and psychopathologies. We analyzed Wave-1 data from 41,869 participants of the National Epidemiologic Survey of Alcohol and Related Conditions (NESARC). Logistic regression showed that as compared to a non-gambling (NG) group, individuals at-risk gambling (ARG) and problem gambling (PPG) demonstrated higher odds of multiple Axis-I and Axis-II disorders in both high- and low-stress groups. Interactions odds ratios were statistically significant for stress moderating the relationships between at-risk gambling (versus non-gambling) and Any Axis-I and Any Axis-II disorder, with substance-use and Cluster-A and Cluster-B disorders contributing significantly. Some similar patterns were observed for pathological gambling (versus non-gambling), with stress moderating relationships with Cluster-B disorders. In all cases, a stronger relationship was observed between problem-gambling severity and psychopathology in the low-stress versus high-stress groups. The findings suggest that perceived stress accounts for some of the variance in the relationship between problem-gambling severity and specific forms of psychopathology, particularly with respect to lower intensity, subsyndromal levels of gambling. Findings suggest that stress may be particularly important to consider in the relationships between problem-gambling severity and substance use and Cluster-B disorders. Published by Elsevier B.V.

  4. The specification-based validation of reliable multicast protocol: Problem Report. M.S. Thesis

    Science.gov (United States)

    Wu, Yunqing

    1995-01-01

    Reliable Multicast Protocol (RMP) is a communication protocol that provides an atomic, totally ordered, reliable multicast service on top of unreliable IP multicasting. In this report, we develop formal models for RMP using existing automated verification systems, and perform validation on the formal RMP specifications. The validation analysis help identifies some minor specification and design problems. We also use the formal models of RMP to generate a test suite for conformance testing of the implementation. Throughout the process of RMP development, we follow an iterative, interactive approach that emphasizes concurrent and parallel progress of implementation and verification processes. Through this approach, we incorporate formal techniques into our development process, promote a common understanding for the protocol, increase the reliability of our software, and maintain high fidelity between the specifications of RMP and its implementation.

  5. Calibration uncertainty

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Anglov, Thomas

    2002-01-01

    Methods recommended by the International Standardization Organisation and Eurachem are not satisfactory for the correct estimation of calibration uncertainty. A novel approach is introduced and tested on actual calibration data for the determination of Pb by ICP-AES. The improved calibration...

  6. Underwater fuel handling equipment maintenance. Verification of design assumptions, specific problems and tools, case study

    International Nuclear Information System (INIS)

    Kurek, J.B.

    1995-01-01

    The majority of CANDU Fuel Transfer System equipment at Pickering is located under fourteen feet of water, as dictated by the containment and shielding requirements. Such arrangement, however, creates specific problems with equipment maintenance. Each single piece of equipment serves two generating units, which means in case of defect- double losses on production, or two units shut down simultaneously for planned maintenance. The requirement for underwater maintenance was not anticipated at the design stage, which multiples the level of difficulty, and creates requirement for developing special tools for each work. Removal of the damaged fuel from the receiving bays and decontamination of submerged equipment is also part of the problem. The purpose of this presentation is to share our experience with the designers, operators, maintenance mechanics and technical personnel of the other CANDU generating stations

  7. Qualification of an out-of-pile Thermohydraulic test Bench (BETHY) developed to calibrate calorimetric cells under specific JHR experimental conditions

    International Nuclear Information System (INIS)

    De Vita, C.; Brun, J.; Carette, M.; Reynard-Carette, C.; Lyoussi, A.; Fourmentel, D.; Villard, J.F.; Guimbal, P.; Malo, J.Y.

    2013-06-01

    Online in-pile measurement methods are crucial during irradiations in material testing reactors to better understand the behavior of materials under accelerated ageing conditions and of nuclear fuels under high irradiation levels. Thus, the construction of a new Material Testing Reactor such as the Jules Horowitz Reactor (JHR) leads to new research and development programs devoted to innovative instrumentation and measurement methods. The presented works are performed in the framework of the IN-CORE program, 'Instrumentation for Nuclear radiations and Calorimetry Online in Reactor', between CEA and Aix-Marseille University. The program aim is to develop experimental devices and test bench to quantify more precisely the nuclear heating parameter in the JHR experimental channels. This in-pile parameter is usually measured by means of calorimeter or gamma thermometer. This paper focuses on a new out-of-pile test bench called BETHY. This bench was developed to study the response of a differential calorimeter during its preliminary calibration step according to specific thermal and hydraulic conditions occurring inside one type of JHR core channel. The first section of this paper is dedicated to a detailed description of the bench. The second part presents the study of the thermal characteristics established in the bench for two main thermal running modes. The last one concerns the calibration curve of the reference cell of the differential calorimeter in the case of homogenous temperature. (authors)

  8. THE PROBLEM OF FORMATION OF THE RUSSIAN NATION AND ITS SPECIFIC MANIFESTATIONS IN THE NORTH CAUCASUS

    Directory of Open Access Journals (Sweden)

    Svetlana Vladimirovna Popova

    2015-11-01

    Full Text Available The task of integration of the Russian civic nation is among the central challenges facing modern Russia. There are many issues to be solved. In particular, what barriers stand in the way? What are the possible mechanisms to overcome them? What is the impact of specific ethnic groups in the process of formation of Russian identity? In this context, it is clear the relevance of understanding the problem at the regional level, the importance of defining the role of the Caucasian identity in the overall system of processes of contemporary Russian socio-cultural transformation.

  9. Problems specific to the piping of sodium-cooled fast breeder reactors

    International Nuclear Information System (INIS)

    Vrillon, B.; Befre, J.; Schaller, K.

    1975-01-01

    A certain number of specific problems arising in connection with the sodium pipes in fast neutron reactors, especially those of large diameter, are presented. The supporting system must be designed to achieve the best compromise among stresses due to weight and various stresses of thermal origin. Large-scale experimental studies carried out on actual elements of the intermediate circuit of the Phenix reactor showed that the circuits can withstand considerable deformation collapse of the walls without danger of leakage. Protection studies against earthquakes are mentionned [fr

  10. Simultaneous calibration phantom commission and geometry calibration in cone beam CT

    Science.gov (United States)

    Xu, Yuan; Yang, Shuai; Ma, Jianhui; Li, Bin; Wu, Shuyu; Qi, Hongliang; Zhou, Linghong

    2017-09-01

    Geometry calibration is a vital step for describing the geometry of a cone beam computed tomography (CBCT) system and is a prerequisite for CBCT reconstruction. In current methods, calibration phantom commission and geometry calibration are divided into two independent tasks. Small errors in ball-bearing (BB) positioning in the phantom-making step will severely degrade the quality of phantom calibration. To solve this problem, we propose an integrated method to simultaneously realize geometry phantom commission and geometry calibration. Instead of assuming the accuracy of the geometry phantom, the integrated method considers BB centers in the phantom as an optimized parameter in the workflow. Specifically, an evaluation phantom and the corresponding evaluation contrast index are used to evaluate geometry artifacts for optimizing the BB coordinates in the geometry phantom. After utilizing particle swarm optimization, the CBCT geometry and BB coordinates in the geometry phantom are calibrated accurately and are then directly used for the next geometry calibration task in other CBCT systems. To evaluate the proposed method, both qualitative and quantitative studies were performed on simulated and realistic CBCT data. The spatial resolution of reconstructed images using dental CBCT can reach up to 15 line pair cm-1. The proposed method is also superior to the Wiesent method in experiments. This paper shows that the proposed method is attractive for simultaneous and accurate geometry phantom commission and geometry calibration.

  11. Calibration factor or calibration coefficient?

    International Nuclear Information System (INIS)

    Meghzifene, A.; Shortt, K.R.

    2002-01-01

    Full text: The IAEA/WHO network of SSDLs was set up in order to establish links between SSDL members and the international measurement system. At the end of 2001, there were 73 network members in 63 Member States. The SSDL network members provide calibration services to end-users at the national or regional level. The results of the calibrations are summarized in a document called calibration report or calibration certificate. The IAEA has been using the term calibration certificate and will continue using the same terminology. The most important information in a calibration certificate is a list of calibration factors and their related uncertainties that apply to the calibrated instrument for the well-defined irradiation and ambient conditions. The IAEA has recently decided to change the term calibration factor to calibration coefficient, to be fully in line with ISO [ISO 31-0], which recommends the use of the term coefficient when it links two quantities A and B (equation 1) that have different dimensions. The term factor should only be used for k when it is used to link the terms A and B that have the same dimensions A=k.B. However, in a typical calibration, an ion chamber is calibrated in terms of a physical quantity such as air kerma, dose to water, ambient dose equivalent, etc. If the chamber is calibrated together with its electrometer, then the calibration refers to the physical quantity to be measured per electrometer unit reading. In this case, the terms referred have different dimensions. The adoption by the Agency of the term coefficient to express the results of calibrations is consistent with the 'International vocabulary of basic and general terms in metrology' prepared jointly by the BIPM, IEC, ISO, OIML and other organizations. The BIPM has changed from factor to coefficient. The authors believe that this is more than just a matter of semantics and recommend that the SSDL network members adopt this change in terminology. (author)

  12. 3D reconstruction of a patient-specific surface model of the proximal femur from calibrated x-ray radiographs: A validation study

    International Nuclear Information System (INIS)

    Zheng Guoyan; Schumann, Steffen

    2009-01-01

    Twenty-three femurs (one plastic bone and twenty-two cadaver bones) with both nonpathologic and pathologic cases were considered to validate a statistical shape model based technique for three-dimensional (3D) reconstruction of a patient-specific surface model from calibrated x-ray radiographs. The 3D reconstruction technique is based on an iterative nonrigid registration of the features extracted from a statistically instantiated 3D surface model to those interactively identified from the radiographs. The surface models reconstructed from the radiographs were compared to the associated ground truths derived either from a 3D CT-scan reconstruction method or from a 3D laser-scan reconstruction method and an average error distance of 0.95 mm were found. Compared to the existing works, our approach has the advantage of seamlessly handling both nonpathologic and pathologic cases even when the statistical shape model that we used was constructed from surface models of nonpathologic bones.

  13. Tissue-specific Calibration of Real-time PCR Facilitates Absolute Quantification of Plasmid DNA in Biodistribution Studies

    Directory of Open Access Journals (Sweden)

    Joan K Ho

    2016-01-01

    Full Text Available Analysis of the tissue distribution of plasmid DNA after administration of nonviral gene delivery systems is best accomplished using quantitative real-time polymerase chain reaction (qPCR, although published strategies do not allow determination of the absolute mass of plasmid delivered to different tissues. Generally, data is expressed as the mass of plasmid relative to the mass of genomic DNA (gDNA in the sample. This strategy is adequate for comparisons of efficiency of delivery to a single site but it does not allow direct comparison of delivery to multiple tissues, as the mass of gDNA extracted per unit mass of each tissue is different. We show here that by constructing qPCR standard curves for each tissue it is possible to determine the dose of intact plasmid remaining in each tissue, which is a more useful parameter when comparing the fates of different formulations of DNA. We exemplify the use of this tissue-specific qPCR method by comparing the delivery of naked DNA, cationic DNA complexes, and neutral PEGylated DNA complexes after intramuscular injection. Generally, larger masses of intact plasmid were present 24 hours after injection of DNA complexes, and neutral complexes resulted in delivery of a larger mass of intact plasmid to the spleen.

  14. Measuring the success of specific health problem consultations in cats and dogs: a systematic review.

    Science.gov (United States)

    Corah, Louise; Mossop, Liz; Cobb, Kate; Dean, Rachel

    2018-03-15

    Consultations are complex interactions, are central to achieving optimal outcomes for all stakeholders, yet what constitutes a successful consultation has not been defined. The aim of this systematic review was to describe the scope of the literature available on specific health problem consultations and appraise their identified success measures. Searches of CAB Abstracts and MEDLINE were performed in May 2016 using species and consultation terms. Systematic sorting of the results allowed identification of consultation 'success factors' cited in peer-reviewed veterinary literature which were appraised using an appropriate critical appraisal tool (AXIS). Searches returned 11 330 results with a total of 17 publications meeting the inclusion criteria, of which four measured consultation success. Journal of the American Veterinary Medical Association was the most common journal of publication (9 of 17) and the majority of included papers had been published since 2010 (12 of 17). Success factors measured were compliance, client satisfaction and veterinary surgeon satisfaction, and publications primarily used communication analysis tools to measure success. The review highlights the paucity of peer-reviewed literature examining small animal, health problem veterinary consultations. The available evidence is of variable quality and provides weak evidence as to which factors contribute to a successful consultation. © British Veterinary Association (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Reduced memory specificity predicts the acquisition of problem solving skills in psychoeducation.

    Science.gov (United States)

    Van Daele, Tom; Van den Bergh, Omer; Van Audenhove, Chantal; Raes, Filip; Hermans, Dirk

    2013-03-01

    Research has shown that overgeneral autobiographical memory (OGM) is a valid predictor for the course of depression. It is not known, however, whether OGM also moderates information uptake and consolidation in a psychoeducation program to prevent stress, anxiety and depression. The present study was designed to investigate whether the Autobiographical Memory Test (AMT; Williams, & Broadbent, 1986) is a valid predictor for the actual unfolding of skills learned through psychoeducation. The questionnaire included primarily the AMT and the Stress Anxiety Depression Means-Ends Problem Solving Questionnaire (SAD-MEPS). It was filled in prior to and after the psychoeducational course by 23 participants. Correlations were calculated for the AMT at baseline and the differences between the pre and post measurements on the SAD-MEPS. Significant correlations were observed between the number of specific responses and the changes in the number of relevant means (r = .49, p < .01). The sample size was rather small, but several checks were able to reduce the chance of spurious findings. These findings may have important implications for the guidance to and the setup of psychoeducational interventions. Suggestions include screening and memory specificity training prior to course commencement. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Nurses' recognition and registration of depression, anxiety and diabetes-specific emotional problems in outpatients with diabetes mellitus

    DEFF Research Database (Denmark)

    Pouwer, Francois; Beekman, Aartjan T F; Lubach, Caroline

    2006-01-01

    OBJECTIVE: The aim of this study was to investigate how often emotional problems were recognized and registered by diabetes nurses. METHODS: We studied medical charts and questionnaire data of 112 diabetes patients. The hospital anxiety, depression scale and the problem areas in diabetes survey...... were used to measure anxiety, depression and diabetes-specific emotional distress. RESULTS: In patients with moderate to severe levels of anxiety or depression, the presence of an emotional problem was recorded in the medical chart in 20-25% of the cases. The registration-rate of diabetes......-specific emotional distress was also found to be low, ranging from 0% (treatment-related problems) to 29% (diabetes-related emotional problems). CONCLUSION: Registration-rates of emotional problems by diabetes nurses were found to be low, but quite similar to detection rates of physicians and nurses in studies...

  17. Emotional and Meta-Emotional Intelligence as Predictors of Adjustment Problems in Students with Specific Learning Disorders

    Science.gov (United States)

    D'Amico, Antonella; Guastaferro, Teresa

    2017-01-01

    The purpose of this study was to analyse adjustment problems in a group of adolescents with a Specific Learning Disorder (SLD), examining to what extent they depend on the severity level of the learning disorder and/or on the individual's level of emotional intelligence. Adjustment problems,, perceived severity levels of SLD, and emotional and…

  18. Overweight in adolescent, psychiatric inpatients: A problem of general or food-specific impulsivity?

    Science.gov (United States)

    Deux, Natalie; Schlarb, Angelika A; Martin, Franziska; Holtmann, Martin; Hebebrand, Johannes; Legenbauer, Tanja

    2017-05-01

    Adolescent psychiatric patients are vulnerable to weight problems and show an overrepresentation of overweight compared to the healthy population. One potential factor that can contribute to the etiology of overweight is higher impulsivity. As of yet, it is unclear whether it is a general impulse control deficit or weight-related aspects such as lower impulse control in response to food that have an impact on body weight. As this may have therapeutic implications, the current study investigated differences between overweight and non-overweight adolescent psychiatric inpatients (N = 98; aged 12-20) in relation to trait impulsivity and behavioral inhibition performance. The Barratt Impulsiveness Scale and two go/no-go paradigms with neutral and food-related stimulus materials were applied. Results indicated no significant differences concerning trait impulsivity, but revealed that overweight inpatients had significantly more difficulties in inhibition performance (i.e. they reacted more impulsively) in response to both food and neutral stimuli compared to non-overweight inpatients. Furthermore, no specific inhibition deficit for high-caloric vs. low-caloric food cues emerged in overweight inpatients, whereas non-overweight participants showed significantly lower inhibition skills in response to high-caloric than low-caloric food stimuli. The results highlight a rather general, non-food-specific reduced inhibition performance in an overweight adolescent psychiatric population. Further research is necessary to enhance the understanding of the role of impulsivity in terms of body weight status in this high-risk group of adolescent inpatients. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Workers' Education in Industrialised Countries and Its Specific Problems in Relation to Development.

    Science.gov (United States)

    Labour Education, 1986

    1986-01-01

    Examines several problems that need to be addressed concerning world crisis: war, poverty, unemployment, overpopulation, environmental issues, and housing; developed versus developing countries; and social justice. The task for workers' education in relation to these problems is discussed. (CT)

  20. Mapping the MMPI-2-RF Specific Problems Scales Onto Extant Psychopathology Structures.

    Science.gov (United States)

    Sellbom, Martin

    2017-01-01

    A main objective in developing the Minnesota Multiphasic Personality Inventory-2-Restructured Form (MMPI-2-RF; Ben-Porath & Tellegen, 2008 ) was to link the hierarchical structure of the instrument's scales to contemporary psychopathology and personality models for greater enhancement of construct validity. Initial evidence published with the Restructured Clinical scales has indicated promising results in that the higher order structure of these measures maps onto those reported in the extant psychopathology literature. This study focused on evaluating the internal structure of the Specific Problems and Interest scales, which have not yet been examined in this manner. Two large, mixed-gender outpatient and correctional samples were used. Exploratory factor analyses revealed consistent evidence for a 4-factor structure representing somatization, negative affect, externalizing, and social detachment. Convergent and discriminant validity analyses in the outpatient sample yielded a pattern of results consistent with expectations. These findings add further evidence to indicate that the MMPI-2-RF hierarchy of scales map onto extant psychopathology literature, and also add support to the notion that somatization and detachment should be considered important higher order domains in the psychopathology literature.

  1. Gamma-ray standards for detector calibration

    International Nuclear Information System (INIS)

    Christmas, P.; Nichols, A.L.; Lorenz, A.

    1987-09-01

    The first official meeting of the IAEA Coordinated Research Programme on the Measurement and Evaluation of X- and Gamma-ray Standards for Detector Calibration was held in Rome from 11 to 13 June 1987. Work undertaken by the CRP members was reviewed in detail: specific problems in the evaluations were identified and actions placed on the participants to resolve these issues. (author). 3 tabs

  2. Social problem-solving in high-functioning schizophrenia: specific deficits in sending skills.

    Science.gov (United States)

    Vaskinn, Anja; Sundet, Kjetil; Hultman, Christina M; Friis, Svein; Andreassen, Ole A

    2009-02-28

    This study examined social problem-solving performance in high-functioning schizophrenia (n=26) and its relation to neurocognition. Ten healthy controls were used as a comparison group. Social problem-solving was assessed with the Assessment of Interpersonal Problem Solving Skills (AIPSS) method. The schizophrenia group was outperformed by healthy controls on all AIPSS measures, reaching statistical significance for sending skills. Exploration of the internal relationship between different aspects of social problem-solving showed that identification of an interpersonal problem (a receiving skill) was not correlated with formulating solutions to the problem (processing skills) or successfully role-playing solutions (interpersonal sending skills). Non-verbal performance in the role-play (an interpersonal sending skill) was not significantly correlated with identification of an interpersonal problem or the generation of solutions. This suggests a dissociation of social problem-solving processes. Social problem-solving was significantly associated with psychomotor speed, verbal learning, semantic fluency and cognitive flexibility. Clinical implications are that remediation of social problem-solving skills should focus on role-playing (nonverbal) interpersonal behaviors, rather than on verbally analyzing an interpersonal problem and clarifying alternative solutions.

  3. Unit-specific calibration of Actigraph accelerometers in a mechanical setup - is it worth the effort? The effect on random output variation caused by technical inter-instrument variability in the laboratory and in the field

    DEFF Research Database (Denmark)

    Moeller, Niels C; Korsholm, Lars; Kristensen, Peter L

    2008-01-01

    BACKGROUND: Potentially, unit-specific in-vitro calibration of accelerometers could increase field data quality and study power. However, reduced inter-unit variability would only be important if random instrument variability contributes considerably to the total variation in field data. Therefor...

  4. Calibration Under Uncertainty.

    Energy Technology Data Exchange (ETDEWEB)

    Swiler, Laura Painton; Trucano, Timothy Guy

    2005-03-01

    This report is a white paper summarizing the literature and different approaches to the problem of calibrating computer model parameters in the face of model uncertainty. Model calibration is often formulated as finding the parameters that minimize the squared difference between the model-computed data (the predicted data) and the actual experimental data. This approach does not allow for explicit treatment of uncertainty or error in the model itself: the model is considered the %22true%22 deterministic representation of reality. While this approach does have utility, it is far from an accurate mathematical treatment of the true model calibration problem in which both the computed data and experimental data have error bars. This year, we examined methods to perform calibration accounting for the error in both the computer model and the data, as well as improving our understanding of its meaning for model predictability. We call this approach Calibration under Uncertainty (CUU). This talk presents our current thinking on CUU. We outline some current approaches in the literature, and discuss the Bayesian approach to CUU in detail.

  5. Kinetics of Hydrogen Radical Reactions with Toluene Including Chemical Activation Theory Employing System-Specific Quantum RRK Theory Calibrated by Variational Transition State Theory.

    Science.gov (United States)

    Bao, Junwei Lucas; Zheng, Jingjing; Truhlar, Donald G

    2016-03-02

    Pressure-dependent reactions are ubiquitous in combustion and atmospheric chemistry. We employ a new calibration procedure for quantum Rice-Ramsperger-Kassel (QRRK) unimolecular rate theory within a chemical activation mechanism to calculate the pressure-falloff effect of a radical association with an aromatic ring. The new theoretical framework is applied to the reaction of H with toluene, which is a prototypical reaction in the combustion chemistry of aromatic hydrocarbons present in most fuels. Both the hydrogen abstraction reactions and the hydrogen addition reactions are calculated. Our system-specific (SS) QRRK approach is adjusted with SS parameters to agree with multistructural canonical variational transition state theory with multidimensional tunneling (MS-CVT/SCT) at the high-pressure limit. The new method avoids the need for the usual empirical estimations of the QRRK parameters, and it eliminates the need for variational transition state theory calculations as a function of energy, although in this first application we do validate the falloff curves by comparing SS-QRRK results without tunneling to multistructural microcanonical variational transition state theory (MS-μVT) rate constants without tunneling. At low temperatures, the two approaches agree well with each other, but at high temperatures, SS-QRRK tends to overestimate falloff slightly. We also show that the variational effect is important in computing the energy-resolved rate constants. Multiple-structure anharmonicity, torsional-potential anharmonicity, and high-frequency-mode vibrational anharmonicity are all included in the rate computations, and torsional anharmonicity effects on the density of states are investigated. Branching fractions, which are both temperature- and pressure-dependent (and for which only limited data is available from experiment), are predicted as a function of pressure.

  6. Radiation Calibration Measurements

    International Nuclear Information System (INIS)

    Omondi, C.

    2017-01-01

    KEBS Radiation Dosimetry mandate are: Custodian of Kenya Standards on Ionizing radiation, Ensure traceability to International System (SI ) and Calibration radiation equipment. RAF 8/040 on Radioisotope applications for troubleshooting and optimizing industrial process established Radiotracer Laboratory objective is to introduce and implement radiotracer technique for problem solving of industrial challenges. Gamma ray scanning technique applied is to Locate blockages, Locate liquid in vapor lines, Locate areas of lost refractory or lining in a pipe and Measure flowing densities. Equipment used for diagnostic and radiation protection must be calibrated to ensure Accuracy and Traceability

  7. PROBLEMS OF ROUTE NETWORK AND AIRCRAFT FLEET OPTIMIZATION AS A SPECIFIC TASK OF AIRLINE STRATEGIC PLANNING

    Directory of Open Access Journals (Sweden)

    M. A. Karakuts

    2015-01-01

    Full Text Available The basic problems of route network and aircraft fleet optimization and its role in airline strategic planning are considered. Measures to improve the methods of its implementation are proposed.

  8. Specific problems of beginners at study of programming and possibilities of their solution

    OpenAIRE

    Procházková, Petra

    2017-01-01

    This thesis deals with the problems of beginners in the study of programming at University of Economics in Prague, Faculty of Informatics and Statistics. This applies particularly to students who are studying the subject Programming in Java.

  9. Specification and implementation of a belief-desire-joint-intention architecture for collaborative problem solving

    OpenAIRE

    Jennings, NR

    1993-01-01

    Systems composed of multiple interacting problem solvers are becoming increasingly pervasive and have been championed in some quarters as the basis of the next generation of intelligent information systems. If this technology is to fulfill its true potential then it is important that the systems which are developed have a sound theoretical grounding. One aspect of this foundation, namely the model of collaborative problem solving, is examined in this paper. A synergistic review of existing mo...

  10. Instrumentation calibration

    International Nuclear Information System (INIS)

    Mack, D.A.

    1976-08-01

    Procedures for the calibration of different types of laboratory equipment are described. Provisions for maintaining the integrity of reference and working standards traceable back to a national standard are discussed. Methods of validation and certification methods are included. An appendix lists available publications and services of national standardizing agencies

  11. Towards a Standard-based Domain-specific Platform to Solve Machine Learning-based Problems

    Directory of Open Access Journals (Sweden)

    Vicente García-Díaz

    2015-12-01

    Full Text Available Machine learning is one of the most important subfields of computer science and can be used to solve a variety of interesting artificial intelligence problems. There are different languages, framework and tools to define the data needed to solve machine learning-based problems. However, there is a great number of very diverse alternatives which makes it difficult the intercommunication, portability and re-usability of the definitions, designs or algorithms that any developer may create. In this paper, we take the first step towards a language and a development environment independent of the underlying technologies, allowing developers to design solutions to solve machine learning-based problems in a simple and fast way, automatically generating code for other technologies. That can be considered a transparent bridge among current technologies. We rely on Model-Driven Engineering approach, focusing on the creation of models to abstract the definition of artifacts from the underlying technologies.

  12. Toward Greater Specificity in Identifying Associations among Interparental Aggression, Child Emotional Reactivity to Conflict, and Child Problems

    Science.gov (United States)

    Davies, Patrick T.; Cicchetti, Dante; Martin, Meredith J.

    2012-01-01

    This study examined specific forms of emotional reactivity to conflict and temperamental emotionality as explanatory mechanisms in pathways among interparental aggression and child psychological problems. Participants of the multimethod, longitudinal study included 201 two-year-old children and their mothers who had experienced elevated violence…

  13. [Development, problems and results of specialty-specific genetic counseling at the Neurology Clinic of the Karl Marx University].

    Science.gov (United States)

    Bachmann, H

    1987-11-01

    Genetic counselling for inherited neurological diseases has been established at the Clinic for Neurology of Karl Marx University. Comprehensive experiences have been got with the specific and sometimes markedly different problems and aims of counselling in Wilsons disease, X-linked recessive muscular dystrophies, myotonic dystrophy and other neuromuscular disorders, Huntingtons chorea and hereditary ataxias.

  14. Brain Hyper-Connectivity and Operation-Specific Deficits during Arithmetic Problem Solving in Children with Developmental Dyscalculia

    Science.gov (United States)

    Rosenberg-Lee, Miriam; Ashkenazi, Sarit; Chen, Tianwen; Young, Christina B.; Geary, David C.; Menon, Vinod

    2015-01-01

    Developmental dyscalculia (DD) is marked by specific deficits in processing numerical and mathematical information despite normal intelligence (IQ) and reading ability. We examined how brain circuits used by young children with DD to solve simple addition and subtraction problems differ from those used by typically developing (TD) children who…

  15. Relations between Young Students' Strategic Behaviours, Domain-Specific Self-Concept, and Performance in a Problem-Solving Situation

    Science.gov (United States)

    Dermitzaki, Irini; Leondari, Angeliki; Goudas, Marios

    2009-01-01

    This study aimed at investigating the relations between students' strategic behaviour during problem solving, task performance and domain-specific self-concept. A total of 167 first- and second-graders were individually examined in tasks involving cubes assembly and in academic self-concept in mathematics. Students' cognitive, metacognitive, and…

  16. Karyotype-specific ear and hearing problems in young adults with turner syndrome and the effect of oxandrolone treatment

    NARCIS (Netherlands)

    Verver, E.J.; Freriks, K.; Sas, T.C.J.; Huygen, P.L.M.; Pennings, R.J.E.; Smeets, D.F.C.M.; Hermus, A.R.M.M.; Menke, L.A.; Wit, J.M.; Otten, B.J.; Velden, J.A.M. van der; Keizer-Schrama, S.M.; Topsakal, V.; Admiraal, R.J.C.; Timmers, H.J.L.M.; Kunst, H.P.M.

    2014-01-01

    OBJECTIVE: To evaluate karyotype-specific ear and hearing problems in young-adult patients with Turner syndrome (TS) and assess the effects of previous treatment with oxandrolone (Ox). STUDY DESIGN: Double-blind follow-up study. SETTING: University hospital. PATIENTS: Sixty-five TS patients (mean

  17. Optimal, Reliability-Based Code Calibration

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard

    2002-01-01

    Reliability based code calibration is considered in this paper. It is described how the results of FORM based reliability analysis may be related to the partial safety factors and characteristic values. The code calibration problem is presented in a decision theoretical form and it is discussed how...... of reliability based code calibration of LRFD based design codes....

  18. An Investigation Into the Navy Public Works Centers Specific Work Service Processing Problems.

    Science.gov (United States)

    1980-12-01

    complex interface of all the elements of individual and organizational behavior. These elements include leadership , motivation, productivity, group...site; variances: nzineering; d. iob control: (ield leadership ; emploYee attitudes; accurac’: or estimates e. and 4ob olans "no problems". 31. Are...indica-ed prcvidinz -he hesr re3s. e I.nck -a- situation or thoughts. The "you" in -.- Il -r your organizatinal element in genera-, .-nis Jn multipie

  19. Gamma counter calibration system

    International Nuclear Information System (INIS)

    1977-01-01

    A method and apparatus are described for the calibration of a gamma radiation measurement instrument to be used over any of a number of different absolute energy ranges. The method includes the steps of adjusting the overall signal gain associated with pulses which are derived from detected gamma rays, until the instrument is calibrated for a particular absolute energy range; then storing parameter settings corresponding to the adjusted overall signal gain, and repeating the process for other desired absolute energy ranges. The stored settings can be subsequently retrieved and reapplied so that test measurements can be made using a selected one of the absolute energy ranges. Means are provided for adjusting the overall signal gain and a specific technique is disclosed for making coarse, then fine adjustments to the signal gain, for rapid convergence of the required calibration settings. (C.F.)

  20. Haplotype reconstruction error as a classical misclassification problem: introducing sensitivity and specificity as error measures.

    Directory of Open Access Journals (Sweden)

    Claudia Lamina

    Full Text Available BACKGROUND: Statistically reconstructing haplotypes from single nucleotide polymorphism (SNP genotypes, can lead to falsely classified haplotypes. This can be an issue when interpreting haplotype association results or when selecting subjects with certain haplotypes for subsequent functional studies. It was our aim to quantify haplotype reconstruction error and to provide tools for it. METHODS AND RESULTS: By numerous simulation scenarios, we systematically investigated several error measures, including discrepancy, error rate, and R(2, and introduced the sensitivity and specificity to this context. We exemplified several measures in the KORA study, a large population-based study from Southern Germany. We find that the specificity is slightly reduced only for common haplotypes, while the sensitivity was decreased for some, but not all rare haplotypes. The overall error rate was generally increasing with increasing number of loci, increasing minor allele frequency of SNPs, decreasing correlation between the alleles and increasing ambiguity. CONCLUSIONS: We conclude that, with the analytical approach presented here, haplotype-specific error measures can be computed to gain insight into the haplotype uncertainty. This method provides the information, if a specific risk haplotype can be expected to be reconstructed with rather no or high misclassification and thus on the magnitude of expected bias in association estimates. We also illustrate that sensitivity and specificity separate two dimensions of the haplotype reconstruction error, which completely describe the misclassification matrix and thus provide the prerequisite for methods accounting for misclassification.

  1. Ultrasonic calibration assembly

    International Nuclear Information System (INIS)

    1981-01-01

    Ultrasonic transducers for in-service inspection of nuclear reactor vessels have several problems associated with them which this invention seeks to overcome. The first is that of calibration or referencing a zero start point for the vertical axis of transducer movement to locate a weld defect. The second is that of verifying the positioning (vertically or at a predetermined angle). Thirdly there is the problem of ascertaining the speed per unit distance in the operating medium of the transducer beam prior to the actual inspection. The apparatus described is a calibration assembly which includes a fixed, generally spherical body having a surface for reflecting an ultrasonic beam from one of the transducers which can be moved until the reflection from the spherical body is the highest amplitude return signal indicating radial alignment from the body. (U.K.)

  2. Specificity of anti-tau antibodies when analyzing mice models of Alzheimer's disease: problems and solutions.

    Directory of Open Access Journals (Sweden)

    Franck R Petry

    Full Text Available Aggregates of hyperphosphorylated tau protein are found in a group of diseases called tauopathies, which includes Alzheimer's disease. The causes and consequences of tau hyperphosphorylation are routinely investigated in laboratory animals. Mice are the models of choice as they are easily amenable to transgenic technology; consequently, their tau phosphorylation levels are frequently monitored by Western blotting using a panel of monoclonal/polyclonal anti-tau antibodies. Given that mouse secondary antibodies can recognize endogenous mouse immunoglobulins (Igs and the possible lack of specificity with some polyclonal antibodies, non-specific signals are commonly observed. Here, we characterized the profiles of commonly used anti-tau antibodies in four different mouse models: non-transgenic mice, tau knock-out (TKO mice, 3xTg-AD mice, and hypothermic mice, the latter a positive control for tau hyperphosphorylation. We identified 3 tau monoclonal antibody categories: type 1, characterized by high non-specificity (AT8, AT180, MC1, MC6, TG-3, type 2, demonstrating low non-specificity (AT270, CP13, CP27, Tau12, TG5, and type 3, with no non-specific signal (DA9, PHF-1, Tau1, Tau46. For polyclonal anti-tau antibodies, some displayed non-specificity (pS262, pS409 while others did not (pS199, pT205, pS396, pS404, pS422, A0024. With monoclonal antibodies, most of the interfering signal was due to endogenous Igs and could be eliminated by different techniques: i using secondary antibodies designed to bind only non-denatured Igs, ii preparation of a heat-stable fraction, iii clearing Igs from the homogenates, and iv using secondary antibodies that only bind the light chain of Igs. All of these techniques removed the non-specific signal; however, the first and the last methods were easier and more reliable. Overall, our study demonstrates a high risk of artefactual signal when performing Western blotting with routinely used anti-tau antibodies, and proposes

  3. A Genre-Specific Investigation of Video Game Engagement and Problem Play in the Early Life Course.

    Science.gov (United States)

    Ream, Geoffrey L; Elliott, Luther C; Dunlap, Eloise

    2013-05-21

    This study explored predictors of engagement with specific video game genres, and degree of problem play experienced by players of specific genres, during the early life course. Video game players ages 18-29 (n = 692) were recruited in and around video game retail outlets, arcades, conventions, and other video game related contexts in New York City. Participants completed a Computer-Assisted Personal Interview (CAPI) of contemporaneous demographic and personality measures and a Life-History Calendar (LHC) measuring video gaming, school/work engagement, and caffeine and sugar consumption for each year of life ages 6 - present. Findings were that likelihood of engagement with most genres rose during childhood, peaked at some point during the second decade of life, and declined through emerging adulthood. Cohorts effects on engagement also emerged which were probably attributable to changes in the availability and popularity of various genres over the 12-year age range of our participants. The relationship between age and problem play of most genres was either negative or non-significant. Sensation-seeking was the only consistent positive predictor of problem play. Relationships between other variables and engagement with and problem play of specific genres are discussed in detail.

  4. Gender-specific mediational links between parenting styles, parental monitoring, impulsiveness, drinking control, and alcohol-related problems.

    Science.gov (United States)

    Patock-Peckham, Julie A; King, Kevin M; Morgan-Lopez, Antonio A; Ulloa, Emilio C; Moses, Jennifer M Filson

    2011-03-01

    Recently, it has been suggested that traits may dynamically change as conditions change. One possible mechanism that may influence impulsiveness is parental monitoring. Parental monitoring reflects a knowledge regarding one's offspring's whereabouts and social connections. The aim of this investigation was to examine potential gender-specific parental influences to impulsiveness (general behavioral control), control over one's own drinking (specific behavioral control), and alcohol-related problems among individuals in a period of emerging adulthood. Direct and mediational links between parenting styles (permissive, authoritarian, and authoritative), parental monitoring, impulsiveness, drinking control, and alcohol-related problems were investigated. A multiple-group, SEM model with (316 women, 265 men) university students was examined. In general, the overall pattern among male and female respondents was distinct. For daughters, perceptions of a permissive father were indirectly linked to more alcohol-related problems through lower levels of monitoring by fathers and more impulsive symptoms. Perceptions of an authoritative father were also indirectly linked to fewer impulsive symptoms through higher levels of monitoring by fathers among daughters. For men, perceptions of a permissive mother were indirectly linked to more alcohol-related problems through lower levels of monitoring by mothers and more impulsive symptoms. For sons, perceptions of mother authoritativeness were indirectly linked to fewer alcohol-related problems through more monitoring by mothers and fewer impulsive symptoms. Monitoring by an opposite-gender parent mediated the link between parenting styles (i.e., permissive, authoritative) on impulsiveness.

  5. Specification of the Advanced Burner Test Reactor Multi-Physics Coupling Demonstration Problem

    Energy Technology Data Exchange (ETDEWEB)

    Shemon, E. R. [Argonne National Lab. (ANL), Argonne, IL (United States); Grudzinski, J. J. [Argonne National Lab. (ANL), Argonne, IL (United States); Lee, C. H. [Argonne National Lab. (ANL), Argonne, IL (United States); Thomas, J. W. [Argonne National Lab. (ANL), Argonne, IL (United States); Yu, Y. Q. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-12-21

    This document specifies the multi-physics nuclear reactor demonstration problem using the SHARP software package developed by NEAMS. The SHARP toolset simulates the key coupled physics phenomena inside a nuclear reactor. The PROTEUS neutronics code models the neutron transport within the system, the Nek5000 computational fluid dynamics code models the fluid flow and heat transfer, and the DIABLO structural mechanics code models structural and mechanical deformation. The three codes are coupled to the MOAB mesh framework which allows feedback from neutronics, fluid mechanics, and mechanical deformation in a compatible format.

  6. Identification of variables for site calibration and power curve assessment in complex terrain. Task 8, a literature survey on theory and practice of parameter identification, specification and estimation (ISE) techniques

    Energy Technology Data Exchange (ETDEWEB)

    Verhoef, J.P.; Leendertse, G.P. [ECN Wind, Petten (Netherlands)

    2001-04-01

    This document presents the literature survey results on Identification, Specification and Estimation (ISE) techniques for variables within the SiteParIden project. Besides an overview of the different general techniques also an overview is given on EU funded wind energy projects where some of these techniques have been applied more specifically. The main problem in applications like power performance assessment and site calibration is to establish an appropriate model for predicting the considered dependent variable with the aid of measured independent (explanatory) variables. In these applications detailed knowledge on what the relevant variables are and how their precise appearance in the model would be is typically missing. Therefore, the identification (of variables) and the specification (of the model relation) are important steps in the model building phase. For the determination of the parameters in the model a reliable variable estimation technique is required. In EU funded wind energy projects the linear regression technique is the most commonly applied tool for the estimation step. The linear regression technique may fail in finding reliable parameter estimates when the model variables are strongly correlated, either due to the experimental set-up or because of their particular appearance in the model. This situation of multicollinearity sometimes results in unrealistic parameter values, e.g. with the wrong algebraic sign. It is concluded that different approaches, like multi-binning can provide a better way of identifying the relevant variables. However further research in these applications is needed and it is recommended that alternative methods (neural networks, singular value decomposition etc.) should also be tested on their usefulness in a succeeding project. Increased interest in complex terrains, as feasible locations for wind farms, has also emphasised the need for adequate models. A common standard procedure to prescribe the statistical

  7. Ontario Hydro's operating experience with steam generators with specifics on Bruce A and Bruce B problems

    Energy Technology Data Exchange (ETDEWEB)

    Eatock, J W; Patterson, R W [Ontario Hydro, Toronto, ON (Canada); Dyck, R W [Ontario Hydro, Central Production Services Division, Toronto, ON (Canada)

    1991-04-01

    The performance of the steam generators in Ontario Hydro nuclear power stations is reviewed. This performance has generally been outstanding compared to world averages, with very low tube failure and plugging rates. Steam generator problems have made only minor contributions to Ontario Hydro nuclear station incapability factors. The mechanisms responsible for the the observed tube degradation and failures are described. The majority of the leaks have been due fatigue in the U-bend of the Bruce 'A' steam generators. There have been very few failures attributed to corrosion of the three tube materials used in Ontario Hydro steam generators. Recent performance has been deteriorating primarily due to deposit accumulation in the steam generators. Plugging of the broached holes in the upper support plates at Bruce 'A' has caused some derating of two units. Increases have been observed in the primary heat transport system reactor inlet temperature of several units. These increases may be attributed to steam generator tube surface fouling. In addition, several units have accumulated deep, hard sludge piles on the tube sheet, although little damage been observed. Recently some fretting of tubes has been observed at BNGSB in the U-bend support region. Remedial measures are being taken to address the current problems. Solutions are being evaluated to reduce the generation of corrosion products in the feedtrain and their subsequent transport to the steam generators. (author)

  8. Ontario Hydro's operating experience with steam generators with specifics on Bruce A and Bruce B problems

    International Nuclear Information System (INIS)

    Eatock, J.W.; Patterson, R.W.; Dyck, R.W.

    1991-01-01

    The performance of the steam generators in Ontario Hydro nuclear power stations is reviewed. This performance has generally been outstanding compared to world averages, with very low tube failure and plugging rates. Steam generator problems have made only minor contributions to Ontario Hydro nuclear station incapability factors. The mechanisms responsible for the the observed tube degradation and failures are described. The majority of the leaks have been due fatigue in the U-bend of the Bruce 'A' steam generators. There have been very few failures attributed to corrosion of the three tube materials used in Ontario Hydro steam generators. Recent performance has been deteriorating primarily due to deposit accumulation in the steam generators. Plugging of the broached holes in the upper support plates at Bruce 'A' has caused some derating of two units. Increases have been observed in the primary heat transport system reactor inlet temperature of several units. These increases may be attributed to steam generator tube surface fouling. In addition, several units have accumulated deep, hard sludge piles on the tube sheet, although little damage been observed. Recently some fretting of tubes has been observed at BNGSB in the U-bend support region. Remedial measures are being taken to address the current problems. Solutions are being evaluated to reduce the generation of corrosion products in the feedtrain and their subsequent transport to the steam generators. (author)

  9. Serious diabetes-specific emotional problems in patients with type 2 diabetes who have different levels of comorbid depression

    DEFF Research Database (Denmark)

    Kokoszka, A; Pouwer, F; Jodko, A

    2009-01-01

    patients with diagnosed depression with those with a subclinical form of depression and those without depression. METHODS: A cross-sectional study was conducted in 101 DM2 patients (51 men and 50 women, mean age = 63,17; SD = 10,74) who completed a standardized, structured psychiatric diagnostic interview...... (MINI), the Beck Depression Inventory, the Hamilton Depression Rating Scale as well as the Problem Areas in Diabetes (PAID) scale (a 20-item measure, with an overall scale measuring diabetes-related emotional distress and four subscales [negative emotions, treatment-related problems, food...... with a depressive disorder (significantly highest PAID score: 39) compared to patients with subclinical depression or no depression. In the group of non-depressed patients, only 14% agreed to have four or more (somewhat) serious diabetes-specific problems. In those with subclinical depression, this percentage...

  10. Gender-specific linkages of parents' childhood physical abuse and neglect with children's problem behaviour: evidence from Japan.

    Science.gov (United States)

    Oshio, Takashi; Umeda, Maki

    2016-05-14

    Childhood abuse has far-reaching effects, not only for survivors of maltreatment but also for subsequent generations. However, the mechanism of such intergenerational linkages has not been fully explored. This study investigated this linkage with special reference to its gender-specific features. A dataset of parents and their children, obtained from a cross-sectional survey in the Tokyo metropolitan area of Japan, was used. The study sample consisted of 1750 children aged between 2 and 18 years (865 daughters and 885 sons) and their parents (1003 mothers and fathers). Regression models were estimated to assess the associations among 1) both parents' childhood physical abuse and neglect (childhood abuse), 2) parents' psychological distress, as measured by the Kessler Psychological Distress Scale (K6), and 3) children's problem behaviour, as measured by the clinical scales of the Child Behavior Checklist. Daughters' problem behaviour was more closely associated with mothers' than fathers' childhood abuse, whereas sons' problem behaviour was more closely associated with their fathers' experience. The impact of mothers' childhood abuse on daughters' problem behaviour was mediated at a rate of around 40 % by both parents' psychological distress. The proportion of the effect mediated by parents' psychological distress was less than 20 % for the impact of fathers' childhood abuse on sons' problem behaviour. The intergenerational impact of parental childhood abuse on children's problem behaviour is gender specific, i.e. largely characterized by the same gender linkages. Further studies that explore the mechanisms involved in the intergenerational impact of childhood abuse are needed.

  11. Physiotherapy ultrasound calibrations

    International Nuclear Information System (INIS)

    Gledhill, M.

    1996-01-01

    Calibration of physiotherapy ultrasound equipment has long been a problem. Numerous surveys around the world over the past 20 years have all found that only a low percentage of the units tested had an output within 30% of that indicatd. In New Zealand, a survey carried out by the NRL in 1985 found that only 24% had an output, at the maximum setting, within + or - 20% of that indicated. The present performance Standard for new equipment (NZS 3200.2.5:1992) requires that the measured output should not deviate from that indicated by more than + or - 30 %. This may be tightened to + or - 20% in the next few years. Any calibration is only as good as the calibration equipment. Some force balances can be tested with small weights to simulate the force exerted by an ultrasound beam, but with others this is not possible. For such balances, testing may only be feasible with a calibrated source which could be used like a transfer standard. (author). 4 refs., 3 figs

  12. Parental smoking and adolescent problem behavior: an adoption study of general and specific effects.

    Science.gov (United States)

    Keyes, Margaret; Legrand, Lisa N; Iacono, William G; McGue, Matt

    2008-10-01

    It is essential to understand the effect of parental smoking on offspring tobacco use. In biologically related families, parents who smoke may transmit a nonspecific genetic risk for offspring disinhibited behavior, including tobacco use. Studying adoptive families allows one to control for genetic confounding when examining the environmental effect of exposure to parental smoking. The purpose of this study was to examine the genetic and environmental contributions to the risk represented by exposure to parental smoking and to assess the specificity of that risk. Adolescents adopted in infancy were systematically ascertained from records of three private Minnesota adoption agencies; nonadopted adolescents were ascertained from Minnesota birth records. Adolescents and their rearing parents participated in all assessments in person. The main outcome measures were self-reports of behavioral deviance, substance use, and personality, as well as DSM-IV clinical assessments of childhood disruptive disorders. The data from adoptive families suggest that exposure to parental smoking represents an environmental risk for substance use in adolescent offspring. In biologically related families, the effect of exposure to parental smoking is larger and more diverse, including substance use, disruptive behavior disorders, delinquency, deviant peer affiliations, aggressive attitudes, and preference for risk taking. This study provides evidence for an environmentally mediated pathway by which parental smoking increases risk specifically for substance use in adolescent offspring. The data are also consistent with a genetically mediated pathway by which nonadoptive parents who smoke may also transmit a nonspecific genetic risk to their offspring for disinhibited behavior.

  13. The problems of material pairs under the specific conditions of high-temperature reactors

    International Nuclear Information System (INIS)

    Schoening, J.

    1981-01-01

    This dissertation gives a detailed descirption of the problems of friction and solid lubrication of slide and ball bearings under HTR conditions. The first part is concerned with an analysis of established approaches for determining the friction factor and the development of a mathematical model on this basis, taking particular account of the following parameters. (1) Surface characteristics (peak-to-valley height, pressure angles of roughness elevations) and, (2) material properties of the friction partner (ductility, brittleness, crystal structure). The formula for friction factor thus arrived at incorporates the microscopic and sub-microscopic influence of the surface grain structure. In addition, the effects of elastic and plastic properties at the region of contact was studied. The derived equation is used to characterise frictional properties and enables a suitable and economic friction pair to be selected. The second part deals with the application of solid lubrication and the effect of the solid lubricant film on the mechanicsm and kinematics of ball bearings. In the final part of this investigation an evaluation of experimental results is carried out on the basis of the preceding theoretical studies in order to confirm the theoretical approach and to provide information of practical use on limits of application, cost details and aids to construction. (orig./IHOE) [de

  14. Problems in the design and specification of containers for vitrified high-level liquid waste

    International Nuclear Information System (INIS)

    Corbet, A.D.W.; Hall, G.G.; Spiller, G.T.

    1976-01-01

    In the United Kingdom the growing problem of ensuring the safe storage of high-level liquid waste over long time scales has led to a policy for implementing solidification. A brief description is given of the HARVEST vitrification process, which is essentially a scaled-up version of the FINGAL process with increased throughput. The functional requirements of the container are considered. It must be made of a material which can be fabricated to a high standard. Diameters up to 600 mm for right circular cylindrical containers and 1200 mm for annular containers are contemplated. Computer aids for axisymmetric and three-dimensional heat transfer and stress analysis are identified. One example is given of the thermal profile for the cylindrical container in the furnace and another example for the annular container following an accident condition. Measured values are given for high temperature oxidation, emissivity and the short-term creep strength of various alloys. Corrosion in fresh water and sea water over long time periods and leaching of partially exposed solid waste are discussed and a conceptual package for sea bed disposal is described. The relative merits of the different methods of manufacture are pointed out and the paper concludes that HK-40 or better INCOLOY alloy 800L are suitable materials of construction. (author)

  15. Self-talk and affective problems in college students: valence of thinking and cognitive content specificity.

    Science.gov (United States)

    Calvete, Esther; Estévez, Ana; Landín, Covadonga; Martínez, Yolanda; Cardeñoso, Olga; Villardón, Lourdes; Villa, Aurelio

    2005-05-01

    The aim of this study was to develop a Self-Talk Inventory for young adults. This inventory consisted of two scales. The Negative Self-Talk Scale included three categories of self-talk (depressive, anxious, and angry thoughts) and the Positive Self-Talk Scale, three categories (minimization, positive orientation, and coping self-instructions). Participants were 982 undergraduate students (Mean age = 20.35 years, SD = 2.16). They completed the self-talk scales together with the following scales to measure symptoms of affective disorders: the Center for Epidemiological Studies Depression Scale (CES-D), the State-Trait Anxiety Inventory (STAI), and the State-Trait Anger Expression Inventory (STAXI-T). Factor analyses confirmed the hypothesized structure for the Self-Talk Inventory. The relations between self-talk and symptoms of affective disorders (depression, anxiety, and anger) were also evaluated. In general, states-of-mind -SOM- ratios and negative cognitions showed a greater association with psychological symptoms than did positive cognitions. Results concerning the cognitive characteristics of depression, anxiety, and anger were mixed and partially supported the cognitive content specificity theory.

  16. Context-Specific Associations Between Harsh Parenting and Peer Rejection on Child Conduct Problems at Home and School.

    Science.gov (United States)

    Tung, Irene; Lee, Steve S

    2016-02-06

    Although harsh parenting and peer rejection are independently associated with childhood conduct problems (CP), these patterns are often informant specific, suggesting that their associations across contexts (i.e., home and school) should be considered. In a sample of 142 children with and without attention-deficit/hyperactivity disorder (ADHD; ages 5-10; 66% male), we used structural equation modeling to evaluate the structure of multi-informant (parent, teacher) and multimethod (semi-structured interview, questionnaire) rated aggressive, rule-breaking, and oppositional behavior. Next, we explored context-specific associations by modeling harsh parenting and peer rejection as simultaneous and independent predictors of home and school CP. We observed several key findings: (a) the structure of parent- and teacher-reported CP was best accounted by context-specific CP (i.e., home vs. school) and a second-order general CP factor; (b) harsh punishment and peer rejection each independently predicted the second-order general CP factor; and (c) peer rejection was uniquely associated with school CP, whereas harsh punishment was associated only with the second-order general CP factor and did not exhibit specificity with home CP. Whereas harsh parenting and peer rejection were each independently associated with generalized CP, peer rejection showed an additional, unique context-specific association with CP exclusively expressed at school. We discuss potential explanatory mechanisms underlying context-specific associations of CP, as well as address etiological and clinical implications for understanding informant-discrepancies in CP.

  17. Calibrated kallikrein generation in human plasma

    DEFF Research Database (Denmark)

    Biltoft, D; Sidelmann, J J; Olsen, L F

    2016-01-01

    generation method as a template. RESULTS: A suitable kallikrein specific fluorogenic substrate was identified (KM=0.91mM, kcat=19s(-1)), and kallikrein generation could be measured in undiluted plasma when silica was added as activator. Disturbing effects, including substrate depletion and the inner......-filter effect, however, affected the signal. These problems were corrected for by external calibration with α2-macroglobulin-kallikrein complexes. Selectivity studies of the substrate, experiments with FXII and PK depleted plasmas, and plasma with high or low complement C1-esterase inhibitor activity indicated...

  18. Emotional and meta-emotional intelligence as predictors of adjustment problems in students with Specific Learning Disorders

    Directory of Open Access Journals (Sweden)

    Antonella D’Amico

    2017-11-01

    Full Text Available The purpose of this study was to analyse adjustment problems in a group of adolescents with a Specific Learning Disorder (SLD, examining to what extent they depend on the severity level of the learning disorder and/or on the individual‟s level of emotional intelligence. Adjustment problems,, perceived severity levels of SLD, and emotional and meta-emotional intelligence were examined in 34 adolescents with SLD. Results demonstrated that emotional beliefs, emotional self-concept and emotional intelligence are very important factors in the psychological adjustment of adolescents with SLD. These results provide evidence for the importance of considering meta-emotional intelligence in both diagnostic and intervention protocols, as well as in the inclusive education of students with SLD.

  19. [Burnout, work disruptions, interpersonal and psychosomatic problems--degree-specific comparison of students at a German university].

    Science.gov (United States)

    Gumz, A; Brähler, E; Heilmann, V K; Erices, R

    2014-03-01

    In the context of the public debate on psychological strain among students, the prevalence of burnout, procrastination, test anxiety, other work disruptions, interpersonal problems and psychic symptoms were analyzed depending on academic degree. The data of 358 college students (of Leipzig University) were examined. The academic degree had only a marginal effect on burnout- and work disruptions-related variables. In terms of interpersonal problems and psychic symptoms, differences between students were identified, depending on the academic degree. Diploma students reported many complaints, whereas undergraduates aspiring for a State Examination, were comparatively less affected. Knowledge of the population-specific psychological load is useful in order to develop preventive and therapeutic measures. © Georg Thieme Verlag KG Stuttgart · New York.

  20. The analytical calibration in (bio)imaging/mapping of the metallic elements in biological samples--definitions, nomenclature and strategies: state of the art.

    Science.gov (United States)

    Jurowski, Kamil; Buszewski, Bogusław; Piekoszewski, Wojciech

    2015-01-01

    Nowadays, studies related to the distribution of metallic elements in biological samples are one of the most important issues. There are many articles dedicated to specific analytical atomic spectrometry techniques used for mapping/(bio)imaging the metallic elements in various kinds of biological samples. However, in such literature, there is a lack of articles dedicated to reviewing calibration strategies, and their problems, nomenclature, definitions, ways and methods used to obtain quantitative distribution maps. The aim of this article was to characterize the analytical calibration in the (bio)imaging/mapping of the metallic elements in biological samples including (1) nomenclature; (2) definitions, and (3) selected and sophisticated, examples of calibration strategies with analytical calibration procedures applied in the different analytical methods currently used to study an element's distribution in biological samples/materials such as LA ICP-MS, SIMS, EDS, XRF and others. The main emphasis was placed on the procedures and methodology of the analytical calibration strategy. Additionally, the aim of this work is to systematize the nomenclature for the calibration terms: analytical calibration, analytical calibration method, analytical calibration procedure and analytical calibration strategy. The authors also want to popularize the division of calibration methods that are different than those hitherto used. This article is the first work in literature that refers to and emphasizes many different and complex aspects of analytical calibration problems in studies related to (bio)imaging/mapping metallic elements in different kinds of biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Calibration of nuclear medicine gamma counters

    International Nuclear Information System (INIS)

    Orlic, M.; Spasic-Jokic, V.; Jovanovic, M.; Vranjes, S. . E-mail address of corresponding author: morlic@vin.bg.ac.yu; Orlic, M.)

    2005-01-01

    In this paper the practical problem of nuclear medicine gamma counters calibration has been solved by using dose calibrators CRC-15R with standard error ±5%. The samples from technetium generators have been measured both by dose calibrators CRC-15R and gamma counter ICN Gamma 3.33 taking into account decay correction. Only the linear part of the curve has practical meaning. The advantage of this procedure satisfies the requirements from international standards: the calibration of sources used for medical exposure be traceable to a standard dosimetry laboratory and radiopharmaceuticals for nuclear medicine procedures be calibrated in terms of activity of the radiopharmaceutical to be administered. (author)

  2. The problem of fuzzy cause-specific death rates in mortality context analysis: the case of Panama City.

    Science.gov (United States)

    Bock, S; Gans, P

    1993-05-01

    In studies of mortality, small and fluctuating numbers of deaths are problems which are caused by infrequent reporting and small spatial unit reporting. To use Panama City as an example, the paper will introduce a Monte Carlo simulation which allows for the analysis of mortality even with small absolute numbers. In addition, Panama City will be used as an example where good medical care is available in every city district, so that social class differences between the districts have a negligible effect on most cause-specific death rates and infant mortality.

  3. Model Calibration in Option Pricing

    Directory of Open Access Journals (Sweden)

    Andre Loerx

    2012-04-01

    Full Text Available We consider calibration problems for models of pricing derivatives which occur in mathematical finance. We discuss various approaches such as using stochastic differential equations or partial differential equations for the modeling process. We discuss the development in the past literature and give an outlook into modern approaches of modelling. Furthermore, we address important numerical issues in the valuation of options and likewise the calibration of these models. This leads to interesting problems in optimization, where, e.g., the use of adjoint equations or the choice of the parametrization for the model parameters play an important role.

  4. Automated Attitude Sensor Calibration: Progress and Plans

    Science.gov (United States)

    Sedlak, Joseph; Hashmall, Joseph

    2004-01-01

    This paper describes ongoing work a NASA/Goddard Space Flight Center to improve the quality of spacecraft attitude sensor calibration and reduce costs by automating parts of the calibration process. The new calibration software can autonomously preview data quality over a given time span, select a subset of the data for processing, perform the requested calibration, and output a report. This level of automation is currently being implemented for two specific applications: inertial reference unit (IRU) calibration and sensor alignment calibration. The IRU calibration utility makes use of a sequential version of the Davenport algorithm. This utility has been successfully tested with simulated and actual flight data. The alignment calibration is still in the early testing stage. Both utilities will be incorporated into the institutional attitude ground support system.

  5. Mercury Continuous Emmission Monitor Calibration

    Energy Technology Data Exchange (ETDEWEB)

    John Schabron; Eric Kalberer; Ryan Boysen; William Schuster; Joseph Rovani

    2009-03-12

    Mercury continuous emissions monitoring systems (CEMs) are being implemented in over 800 coal-fired power plant stacks throughput the U.S. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor calibrators/generators. These devices are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 and vacated by a Federal appeals court in early 2008 required that calibration be performed with NIST-traceable standards. Despite the vacature, mercury emissions regulations in the future will require NIST traceable calibration standards, and EPA does not want to interrupt the effort towards developing NIST traceability protocols. The traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued a conceptual interim traceability protocol for elemental mercury calibrators. The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The EPA traceability protocol document is divided into two separate sections. The first deals with the qualification of calibrator models by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the calibrators that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma

  6. Dosimetry and Calibration Section

    International Nuclear Information System (INIS)

    Otto, T.

    1998-01-01

    The two tasks of the Dosimetry and Calibration Section at CERN are the Individual Dosimetry Service which assures the personal monitoring of about 5000 persons potentially exposed to ionizing radiation at CERN, and the Calibration Laboratory which verifies all the instruments and monitors. This equipment is used by the sections of the RP Group for assuring radiation protection around CERN's accelerators, and by the Environmental Section of TISTE. In addition, nearly 250 electronic and 300 quartz fibre dosimeters, employed in operational dosimetry, are calibrated at least once a year. The Individual Dosimetry Service uses an extended database (INDOS) which contains information about all the individual doses ever received at CERN. For most of 1997 it was operated without the support of a database administrator as the technician who had assured this work retired. The Software Support Section of TIS-TE took over the technical responsibility of the database, but in view of the many other tasks of this Section and the lack of personnel, only a few interventions for solving immediate problems were possible

  7. Is Poor Frequency Modulation Detection Linked to Literacy Problems? A Comparison of Specific Reading Disability and Mild to Moderate Sensorineural Hearing Loss

    Science.gov (United States)

    Halliday, L. F.; Bishop, D. V. M.

    2006-01-01

    Specific reading disability (SRD) is now widely recognised as often being caused by phonological processing problems, affecting analysis of spoken as well as written language. According to one theoretical account, these phonological problems are due to low-level problems in auditory perception of dynamic acoustic cues. Evidence for this has come…

  8. A Calibrated Test-Set for Measurement of Access-Point Time Specifications in Hybrid Wired/Wireless Industrial Communication †

    Directory of Open Access Journals (Sweden)

    Federico Tramarin

    2018-05-01

    Full Text Available In factory automation and process control systems, hybrid wired/wireless networks are often deployed to connect devices of difficult reachability such as those mounted on mobile equipment. A widespread implementation of these networks makes use of Access Points (APs to implement wireless extensions of Real-Time Ethernet (RTE networks via the IEEE 802.11 Wireless LAN (WLAN. Unfortunately, APs may introduce random delays in frame forwarding, mainly related to their internal behavior (e.g., queue management, processing times, that clearly impact the overall worst case execution time of real-time tasks involved in industrial process control systems. As a consequence, the knowledge of such delays becomes a crucial design parameter, and their estimation is definitely of utter importance. In this scenario, the paper presents an original and effective method to measure the aforementioned delays introduced by APs, exploiting a hybrid loop-back link and a simple, yet accurate set-up with moderate instrumentation requirements. The proposed method, which requires an initial calibration phase by means of a reference AP, has been successfully tested on some commercial APs to prove its effectiveness. The proposed measurement procedure is proven to be general and, as such, can be profitably adopted in even different scenarios.

  9. Using auditory pre-information to solve the cocktail-party problem: electrophysiological evidence for age-specific differences.

    Science.gov (United States)

    Getzmann, Stephan; Lewald, Jörg; Falkenstein, Michael

    2014-01-01

    Speech understanding in complex and dynamic listening environments requires (a) auditory scene analysis, namely auditory object formation and segregation, and (b) allocation of the attentional focus to the talker of interest. There is evidence that pre-information is actively used to facilitate these two aspects of the so-called "cocktail-party" problem. Here, a simulated multi-talker scenario was combined with electroencephalography to study scene analysis and allocation of attention in young and middle-aged adults. Sequences of short words (combinations of brief company names and stock-price values) from four talkers at different locations were simultaneously presented, and the detection of target names and the discrimination between critical target values were assessed. Immediately prior to speech sequences, auditory pre-information was provided via cues that either prepared auditory scene analysis or attentional focusing, or non-specific pre-information was given. While performance was generally better in younger than older participants, both age groups benefited from auditory pre-information. The analysis of the cue-related event-related potentials revealed age-specific differences in the use of pre-cues: Younger adults showed a pronounced N2 component, suggesting early inhibition of concurrent speech stimuli; older adults exhibited a stronger late P3 component, suggesting increased resource allocation to process the pre-information. In sum, the results argue for an age-specific utilization of auditory pre-information to improve listening in complex dynamic auditory environments.

  10. Using auditory pre-information to solve the cocktail-party problem: electrophysiological evidence for age-specific differences

    Directory of Open Access Journals (Sweden)

    Stephan eGetzmann

    2014-12-01

    Full Text Available Speech understanding in complex and dynamic listening environments requires (a auditory scene analysis, namely auditory object formation and segregation, and (b allocation of the attentional focus to the talker of interest. There is evidence that pre-information is actively used to facilitate these two aspects of the so-called cocktail-party problem. Here, a simulated multi-talker scenario was combined with electroencephalography to study scene analysis and allocation of attention in young and middle-aged adults. Sequences of short words (combinations of brief company names and stock-price values from four talkers at different locations were simultaneously presented, and the detection of target names and the discrimination between critical target values were assessed. Immediately prior to speech sequences, auditory pre-information was provided via cues that either prepared auditory scene analysis or attentional focusing, or non-specific pre-information was given. While performance was generally better in younger than older participants, both age groups benefited from auditory pre-information. The analysis of the cue-related event-related potentials revealed age-specific differences in the use of pre-cues: Younger adults showed a pronounced N2 component, suggesting early inhibition of concurrent speech stimuli; older adults exhibited a stronger late P3 component, suggesting increased resource allocation to process the pre-information. In sum, the results argue for an age-specific utilization of auditory pre-information to improve listening in complex dynamic auditory environments.

  11. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-01-01

    The performance of diagnostic systems are limited by their weakest constituents, including their calibration issues. Neutron diagnostics are notorious for problems encountered while determining their absolute calibrations, due mainly to the nature of the neutron transport problem. In order to facilitate the determination of an accurate and precise calibration, the diagnostic design should be such as to minimize the scattered neutron flux. ITER will use a comprehensive set of neutron diagnostics--comprising radial and vertical neutron cameras, neutron spectrometers, a neutron activation system and internal and external fission chambers--to provide accurate measurements of fusion power and power densities as a function of time. The calibration of such an important diagnostic system merits careful consideration. Some thoughts have already been given to this subject during the conceptual design phase in relation to the time-integrated neutron activation and time-dependent neutron yield monitors. However, no overall calibration strategy has been worked out so far. This paper represents a first attempt to address this vital issue. Experience gained from present large tokamaks (JET, TFTR and JT60U) and proposals for ITER are reviewed. The need to use a 14-MeV neutron generator as opposed to radioactive sources for in-situ calibration of D-T diagnostics will be stressed. It is clear that the overall absolute determination of fusion power will have to rely on a combination of nuclear measuring techniques, for which the provision of accurate and independent calibrations will constitute an ongoing process as ITER moves from one phase of operation to the next

  12. Stimulus Dependency of Object-Evoked Responses in Human Visual Cortex: An Inverse Problem for Category Specificity

    Science.gov (United States)

    Graewe, Britta; De Weerd, Peter; Farivar, Reza; Castelo-Branco, Miguel

    2012-01-01

    Many studies have linked the processing of different object categories to specific event-related potentials (ERPs) such as the face-specific N170. Despite reports showing that object-related ERPs are influenced by visual stimulus features, there is consensus that these components primarily reflect categorical aspects of the stimuli. Here, we re-investigated this idea by systematically measuring the effects of visual feature manipulations on ERP responses elicited by both structure-from-motion (SFM)-defined and luminance-defined object stimuli. SFM objects elicited a novel component at 200–250 ms (N250) over parietal and posterior temporal sites. We found, however, that the N250 amplitude was unaffected by restructuring SFM stimuli into meaningless objects based on identical visual cues. This suggests that this N250 peak was not uniquely linked to categorical aspects of the objects, but is strongly determined by visual stimulus features. We provide strong support for this hypothesis by parametrically manipulating the depth range of both SFM- and luminance-defined object stimuli and showing that the N250 evoked by SFM stimuli as well as the well-known N170 to static faces were sensitive to this manipulation. Importantly, this effect could not be attributed to compromised object categorization in low depth stimuli, confirming a strong impact of visual stimulus features on object-related ERP signals. As ERP components linked with visual categorical object perception are likely determined by multiple stimulus features, this creates an interesting inverse problem when deriving specific perceptual processes from variations in ERP components. PMID:22363479

  13. Evaluating Statistical Process Control (SPC) techniques and computing the uncertainty of force calibrations

    Science.gov (United States)

    Navard, Sharon E.

    1989-01-01

    In recent years there has been a push within NASA to use statistical techniques to improve the quality of production. Two areas where statistics are used are in establishing product and process quality control of flight hardware and in evaluating the uncertainty of calibration of instruments. The Flight Systems Quality Engineering branch is responsible for developing and assuring the quality of all flight hardware; the statistical process control methods employed are reviewed and evaluated. The Measurement Standards and Calibration Laboratory performs the calibration of all instruments used on-site at JSC as well as those used by all off-site contractors. These calibrations must be performed in such a way as to be traceable to national standards maintained by the National Institute of Standards and Technology, and they must meet a four-to-one ratio of the instrument specifications to calibrating standard uncertainty. In some instances this ratio is not met, and in these cases it is desirable to compute the exact uncertainty of the calibration and determine ways of reducing it. A particular example where this problem is encountered is with a machine which does automatic calibrations of force. The process of force calibration using the United Force Machine is described in detail. The sources of error are identified and quantified when possible. Suggestions for improvement are made.

  14. DEM Calibration Approach: design of experiment

    Science.gov (United States)

    Boikov, A. V.; Savelev, R. V.; Payor, V. A.

    2018-05-01

    The problem of DEM models calibration is considered in the article. It is proposed to divide models input parameters into those that require iterative calibration and those that are recommended to measure directly. A new method for model calibration based on the design of the experiment for iteratively calibrated parameters is proposed. The experiment is conducted using a specially designed stand. The results are processed with technical vision algorithms. Approximating functions are obtained and the error of the implemented software and hardware complex is estimated. The prospects of the obtained results are discussed.

  15. Online Sensor Calibration Assessment in Nuclear Power Systems

    International Nuclear Information System (INIS)

    Coble, Jamie B.; Ramuhalli, Pradeep; Meyer, Ryan M.; Hashemian, Hash

    2013-01-01

    Safe, efficient, and economic operation of nuclear systems (nuclear power plants, fuel fabrication and storage, used fuel processing, etc.) relies on transmission of accurate and reliable measurements. During operation, sensors degrade due to age, environmental exposure, and maintenance interventions. Sensor degradation can affect the measured and transmitted signals, including sensor failure, signal drift, sensor response time, etc. Currently, periodic sensor recalibration is performed to avoid these problems. Sensor recalibration activities include both calibration assessment and adjustment (if necessary). In nuclear power plants, periodic recalibration of safety-related sensors is required by the plant technical specifications. Recalibration typically occurs during refueling outages (about every 18 to 24 months). Non-safety-related sensors also undergo recalibration, though not as frequently. However, this approach to maintaining sensor calibration and performance is time-consuming and expensive, leading to unnecessary maintenance, increased radiation exposure to maintenance personnel, and potential damage to sensors. Online monitoring (OLM) of sensor performance is a non-invasive approach to assess instrument calibration. OLM can mitigate many of the limitations of the current periodic recalibration practice by providing more frequent assessment of calibration and identifying those sensors that are operating outside of calibration tolerance limits without removing sensors or interrupting operation. This can support extended operating intervals for unfaulted sensors and target recalibration efforts to only degraded sensors

  16. CALIBRATED HYDRODYNAMIC MODEL

    Directory of Open Access Journals (Sweden)

    Sezar Gülbaz

    2015-01-01

    Full Text Available The land development and increase in urbanization in a watershed affect water quantityand water quality. On one hand, urbanization provokes the adjustment of geomorphicstructure of the streams, ultimately raises peak flow rate which causes flood; on theother hand, it diminishes water quality which results in an increase in Total SuspendedSolid (TSS. Consequently, sediment accumulation in downstream of urban areas isobserved which is not preferred for longer life of dams. In order to overcome thesediment accumulation problem in dams, the amount of TSS in streams and inwatersheds should be taken under control. Low Impact Development (LID is a BestManagement Practice (BMP which may be used for this purpose. It is a land planningand engineering design method which is applied in managing storm water runoff inorder to reduce flooding as well as simultaneously improve water quality. LID includestechniques to predict suspended solid loads in surface runoff generated over imperviousurban surfaces. In this study, the impact of LID-BMPs on surface runoff and TSS isinvestigated by employing a calibrated hydrodynamic model for Sazlidere Watershedwhich is located in Istanbul, Turkey. For this purpose, a calibrated hydrodynamicmodel was developed by using Environmental Protection Agency Storm WaterManagement Model (EPA SWMM. For model calibration and validation, we set up arain gauge and a flow meter into the field and obtain rainfall and flow rate data. Andthen, we select several LID types such as retention basins, vegetative swales andpermeable pavement and we obtain their influence on peak flow rate and pollutantbuildup and washoff for TSS. Consequently, we observe the possible effects ofLID on surface runoff and TSS in Sazlidere Watershed.

  17. Calibration Procedures in Mid Format Camera Setups

    Science.gov (United States)

    Pivnicka, F.; Kemper, G.; Geissler, S.

    2012-07-01

    A growing number of mid-format cameras are used for aerial surveying projects. To achieve a reliable and geometrically precise result also in the photogrammetric workflow, awareness on the sensitive parts is important. The use of direct referencing systems (GPS/IMU), the mounting on a stabilizing camera platform and the specific values of the mid format camera make a professional setup with various calibration and misalignment operations necessary. An important part is to have a proper camera calibration. Using aerial images over a well designed test field with 3D structures and/or different flight altitudes enable the determination of calibration values in Bingo software. It will be demonstrated how such a calibration can be performed. The direct referencing device must be mounted in a solid and reliable way to the camera. Beside the mechanical work especially in mounting the camera beside the IMU, 2 lever arms have to be measured in mm accuracy. Important are the lever arms from the GPS Antenna to the IMU's calibrated centre and also the lever arm from the IMU centre to the Camera projection centre. In fact, the measurement with a total station is not a difficult task but the definition of the right centres and the need for using rotation matrices can cause serious accuracy problems. The benefit of small and medium format cameras is that also smaller aircrafts can be used. Like that, a gyro bases stabilized platform is recommended. This causes, that the IMU must be mounted beside the camera on the stabilizer. The advantage is, that the IMU can be used to control the platform, the problematic thing is, that the IMU to GPS antenna lever arm is floating. In fact we have to deal with an additional data stream, the values of the movement of the stabiliser to correct the floating lever arm distances. If the post-processing of the GPS-IMU data by taking the floating levers into account, delivers an expected result, the lever arms between IMU and camera can be applied

  18. CALIBRATION PROCEDURES IN MID FORMAT CAMERA SETUPS

    Directory of Open Access Journals (Sweden)

    F. Pivnicka

    2012-07-01

    Full Text Available A growing number of mid-format cameras are used for aerial surveying projects. To achieve a reliable and geometrically precise result also in the photogrammetric workflow, awareness on the sensitive parts is important. The use of direct referencing systems (GPS/IMU, the mounting on a stabilizing camera platform and the specific values of the mid format camera make a professional setup with various calibration and misalignment operations necessary. An important part is to have a proper camera calibration. Using aerial images over a well designed test field with 3D structures and/or different flight altitudes enable the determination of calibration values in Bingo software. It will be demonstrated how such a calibration can be performed. The direct referencing device must be mounted in a solid and reliable way to the camera. Beside the mechanical work especially in mounting the camera beside the IMU, 2 lever arms have to be measured in mm accuracy. Important are the lever arms from the GPS Antenna to the IMU's calibrated centre and also the lever arm from the IMU centre to the Camera projection centre. In fact, the measurement with a total station is not a difficult task but the definition of the right centres and the need for using rotation matrices can cause serious accuracy problems. The benefit of small and medium format cameras is that also smaller aircrafts can be used. Like that, a gyro bases stabilized platform is recommended. This causes, that the IMU must be mounted beside the camera on the stabilizer. The advantage is, that the IMU can be used to control the platform, the problematic thing is, that the IMU to GPS antenna lever arm is floating. In fact we have to deal with an additional data stream, the values of the movement of the stabiliser to correct the floating lever arm distances. If the post-processing of the GPS-IMU data by taking the floating levers into account, delivers an expected result, the lever arms between IMU and

  19. An Exact Confidence Region in Multivariate Calibration

    OpenAIRE

    Mathew, Thomas; Kasala, Subramanyam

    1994-01-01

    In the multivariate calibration problem using a multivariate linear model, an exact confidence region is constructed. It is shown that the region is always nonempty and is invariant under nonsingular transformations.

  20. Reliability-Based Code Calibration

    DEFF Research Database (Denmark)

    Faber, M.H.; Sørensen, John Dalsgaard

    2003-01-01

    The present paper addresses fundamental concepts of reliability based code calibration. First basic principles of structural reliability theory are introduced and it is shown how the results of FORM based reliability analysis may be related to partial safety factors and characteristic values....... Thereafter the code calibration problem is presented in its principal decision theoretical form and it is discussed how acceptable levels of failure probability (or target reliabilities) may be established. Furthermore suggested values for acceptable annual failure probabilities are given for ultimate...... and serviceability limit states. Finally the paper describes the Joint Committee on Structural Safety (JCSS) recommended procedure - CodeCal - for the practical implementation of reliability based code calibration of LRFD based design codes....

  1. Nonword repetition--a clinical marker for specific language impairment in Swedish associated with parents' language-related problems.

    Directory of Open Access Journals (Sweden)

    Nelli Kalnak

    Full Text Available First, we explore the performance of nonword repetition (NWR in children with specific language impairment (SLI and typically developing children (TD in order to investigate the accuracy of NWR as a clinical marker for SLI in Swedish-speaking school-age children. Second, we examine the relationship between NWR, family aggregation, and parental level of education in children with SLI. A sample of 61 children with SLI, and 86 children with TD, aged 8-12 years, were administered an NWR test. Family aggregation, measured as the prevalence of language and/or literacy problems (LLP in parents of the children with SLI, was based on family history interviews. The sensitivity and specificity of nonword repetition was analyzed in a binary logistic regression, cut-off values were established with ROC curves, and positive and negative likelihood ratios reported. Results from the present study show that NWR distinguishes well between Swedish-speaking school-children with and without SLI. We found 90.2% sensitivity and 97.7% specificity at a cut-off level of -2 standard deviations for binary scoring of nonwords. Differences between the SLI and TD groups showed large effect sizes for the two scoring measures binary (d = 2.11 and percent correct consonants (PCC (d = 1.79. The children with SLI were split into two subgroups: those with no parents affected with LLP (n = 12, and those with one or both parents affected (n = 49. The subgroup consisting of affected parents had a significantly lower score on NWR binary (p = .037, and there was a great difference between the subgroups (d = 0.7. When compared to the TD group, the difference from the subgroup with affected parents was almost one standard deviation larger (d = 2.47 than the difference from the TD to the subgroup consisting of non-affected parents (d = 1.57. Our study calls for further exploration of the complex interaction between family aggregation, language input, and

  2. Mechanics of log calibration

    International Nuclear Information System (INIS)

    Waller, W.C.; Cram, M.E.; Hall, J.E.

    1975-01-01

    For any measurement to have meaning, it must be related to generally accepted standard units by a valid and specified system of comparison. To calibrate well-logging tools, sensing systems are designed which produce consistent and repeatable indications over the range for which the tool was intended. The basics of calibration theory, procedures, and calibration record presentations are reviewed. Calibrations for induction, electrical, radioactivity, and sonic logging tools will be discussed. The authors' intent is to provide an understanding of the sources of errors, of the way errors are minimized in the calibration process, and of the significance of changes in recorded calibration data

  3. Mercury CEM Calibration

    Energy Technology Data Exchange (ETDEWEB)

    John Schabron; Joseph Rovani; Mark Sanderson

    2008-02-29

    Mercury continuous emissions monitoring systems (CEMS) are being implemented in over 800 coal-fired power plant stacks. The power industry desires to conduct at least a full year of monitoring before the formal monitoring and reporting requirement begins on January 1, 2009. It is important for the industry to have available reliable, turnkey equipment from CEM vendors. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor generators. The generators are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 requires that calibration be performed with NIST-traceable standards (Federal Register 2007). Traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued an interim traceability protocol for elemental mercury generators (EPA 2007). The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The document is divided into two separate sections. The first deals with the qualification of generators by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the generator models that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma/mass spectrometry performed by NIST in Gaithersburg, MD. The

  4. Simulation and calibration of the specific energy loss of the central jet chambers of the H1 detector and measurement of the inclusive D*± meson cross section in photoproduction at HERA

    International Nuclear Information System (INIS)

    Hennekemper, Eva

    2011-12-01

    In this thesis the photoproduction of D * mesons in ep collisions at HERA is analysed. D * mesons are detected in the 'golden' decay channel D * → Kππ s with the H1 detector. Compared to earlier analyses, the systematic uncertainty is reduced due to two main improvements. Firstly, the simulation of the Fast Track Trigger, which is based on tracks measured within the central jet chambers, allows the trigger efficiency dependence of various kinematic variables to be evaluated. Secondly, the use of specific energy loss provides the possibility to suppress the non-resonant background. In order to use particle identification with the specific energy loss in the analysis, the simulation of the specific energy loss in the central jet chambers of the H1 detector is improved and the necessary correction functions and calibrations have been determined. This improved final H1 detector simulation is used to determine the cross section of photoproduction of D * mesons in the HERA II data sample, which corresponds to an integrated luminosity of 113 pb -1 . The measurement was performed in the kinematic region of Q 2 γp * mesons with transverse momenta above 1.8 GeV and in the central pseudorapidity range of vertical stroke η(D * ) vertical stroke <1.5 are determined and are compared to leading and next to leading order QCD predictions. (orig.)

  5. Investigation on calibration parameter of mammography calibration facilities at MINT

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Wan Hazlinda Ismail; Md Saion Salikin; Muhammad Jamal Md Isa; Azuhar Ripin; Norriza Mohd Isa

    2004-01-01

    A mammography calibration facility has been established in the Medical Physics Laboratory, Malaysian Institute for Nuclear Technology Research (MINT). The calibration facility is established at the national level mainly to provide calibration services for radiation measuring test instruments or test tools used in quality assurance programme in mammography, which is being implemented in Malaysia. One of the accepted parameters that determine the quality of a radiation beam is the homogeneity coefficient. It is determined from the values of the 1 st and 2 nd Half Value Layer (HVL). In this paper, the consistency of the mammography machine beam qualities that is available in MINT, is investigated and presented. For calibration purposes, five radiation qualities namely 23, 25, 28, 30 and 35 kV, selectable from the control panel of the X-ray machine is used. Important parameters that are set for this calibration facility are exposure time, tube current, focal spot to detector distance (FDD) and beam size at specific distance. The values of homogeneity coefficient of this laboratory for the past few years tip to now be presented in this paper. Backscatter radiations are also considered in this investigation. (Author)

  6. Instrument Calibration and Certification Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Davis, R. Wesley [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-05-31

    The Amptec 640SL-2 is a 4-wire Kelvin failsafe resistance meter, designed to reliably use very low-test currents for its resistance measurements. The 640SL-1 is a 2-wire version, designed to support customers using the Reynolds Industries type 311 connector. For both versions, a passive (analog) dual function DC Milliameter/Voltmeter allows the user to verify the actual 640SL output current level and the open circuit voltage on the test leads. This procedure includes tests of essential performance parameters. Any malfunction noticed during calibration, whether specifically tested for or not, shall be corrected before calibration continues or is completed.

  7. ORNL calibrations facility

    International Nuclear Information System (INIS)

    Berger, C.D.; Gupton, E.D.; Lane, B.H.; Miller, J.H.; Nichols, S.W.

    1982-08-01

    The ORNL Calibrations Facility is operated by the Instrumentation Group of the Industrial Safety and Applied Health Physics Division. Its primary purpose is to maintain radiation calibration standards for calibration of ORNL health physics instruments and personnel dosimeters. This report includes a discussion of the radioactive sources and ancillary equipment in use and a step-by-step procedure for calibration of those survey instruments and personnel dosimeters in routine use at ORNL

  8. New method to calibrate a spinner anemometer

    DEFF Research Database (Denmark)

    Demurtas, Giorgio; Friis Pedersen, Troels

    2014-01-01

    The spinner anemometer is a wind sensor, based on three one dimensional sonic sensor probes, mounted on the wind turbine spinner, and an algorithm to convert the wind speeds measured by the three sonic sensors to horizontal wind speed, yaw misalignment and flow inclination angle. The conversion...... algorithm utilizes two constants k1 and k2 that are specific to the spinner and blade root design and to the mounting position of the sonic sensors on the spinner. The two constants are calibrated by means of two different test and instrument set-ups. Both calibrations consider the rotor of the wind turbine...... to be stopped during calibration in order for the rotor induction not to influence on the calibration, so that the spinner anemometer measures ”free” wind values in stopped condition. The calibration of flow angle measurements is made by calibration of the ratio of the two algorithm constants k2=k1 = k...

  9. XRD alignment, calibration and performance

    International Nuclear Information System (INIS)

    Davy, L.

    2002-01-01

    Full text: The quality of any diffractometer system is very much dependent on the alignment, calibration and performance. The three subjects are very much related. Firstly, you must know how to carry out the full diffractometer alignment. XRD alignment is easy once you know how. The presentation will show you step by step to carry out the full alignment. Secondly, you need to know how to calibrate the diffractometer system. The presentation will show you how to calibrate the goniometer, detector etc. Thirdly, to prove the system is working within the manufacturer specification. The presentation will show you how to carry out the resolution, reproducibility and linearity test. Copyright (2002) Australian X-ray Analytical Association Inc

  10. Better Drumming Through Calibration: Techniques for Pre-Performance Robotic Percussion Optimization

    OpenAIRE

    Murphy, Jim; Kapur, Ajay; Carnegie, Dale

    2012-01-01

    A problem with many contemporary musical robotic percussion systems lies in the fact that solenoids fail to respond lin-early to linear increases in input velocity. This nonlinearity forces performers to individually tailor their compositions to specific robotic drummers. To address this problem, we introduce a method of pre-performance calibration using metaheuristic search techniques. A variety of such techniques are introduced and evaluated and the results of the optimized solenoid-based p...

  11. Sensor Calibration Design Based on D-Optimality Criterion

    Directory of Open Access Journals (Sweden)

    Hajiyev Chingiz

    2016-09-01

    Full Text Available In this study, a procedure for optimal selection of measurement points using the D-optimality criterion to find the best calibration curves of measurement sensors is proposed. The coefficients of calibration curve are evaluated by applying the classical Least Squares Method (LSM. As an example, the problem of optimal selection for standard pressure setters when calibrating a differential pressure sensor is solved. The values obtained from the D-optimum measurement points for calibration of the differential pressure sensor are compared with those from actual experiments. Comparison of the calibration errors corresponding to the D-optimal, A-optimal and Equidistant calibration curves is done.

  12. Infrared stereo calibration for unmanned ground vehicle navigation

    Science.gov (United States)

    Harguess, Josh; Strange, Shawn

    2014-06-01

    The problem of calibrating two color cameras as a stereo pair has been heavily researched and many off-the-shelf software packages, such as Robot Operating System and OpenCV, include calibration routines that work in most cases. However, the problem of calibrating two infrared (IR) cameras for the purposes of sensor fusion and point could generation is relatively new and many challenges exist. We present a comparison of color camera and IR camera stereo calibration using data from an unmanned ground vehicle. There are two main challenges in IR stereo calibration; the calibration board (material, design, etc.) and the accuracy of calibration pattern detection. We present our analysis of these challenges along with our IR stereo calibration methodology. Finally, we present our results both visually and analytically with computed reprojection errors.

  13. Quality Management and Calibration

    Science.gov (United States)

    Merkus, Henk G.

    Good specification of a product’s performance requires adequate characterization of relevant properties. Particulate products are usually characterized by some PSD, shape or porosity parameter(s). For proper characterization, adequate sampling, dispersion, and measurement procedures should be available or developed and skilful personnel should use appropriate, well-calibrated/qualified equipment. The characterization should be executed, in agreement with customers, in a wellorganized laboratory. All related aspects should be laid down in a quality handbook. The laboratory should provide proof for its capability to perform the characterization of stated products and/or reference materials within stated confidence limits. This can be done either by internal validation and audits or by external GLP accreditation.

  14. Intercomparison and calibration of dose calibrators used in nuclear medicine facilities

    CERN Document Server

    Costa, A M D

    2003-01-01

    The aim of this work was to establish a working standard for intercomparison and calibration of dose calibrators used in most of nuclear medicine facilities for the determination of the activity of radionuclides administered to patients in specific examinations or therapeutic procedures. A commercial dose calibrator, a set of standard radioactive sources, and syringes, vials and ampoules with radionuclide solutions used in nuclear medicine were utilized in this work. The commercial dose calibrator was calibrated for radionuclide solutions used in nuclear medicine. Simple instrument tests, such as linearity response and variation response with the source volume at a constant source activity concentration were performed. This instrument may be used as a reference system for intercomparison and calibration of other activity meters, as a method of quality control of dose calibrators utilized in nuclear medicine facilities.

  15. A twin study exploring the association between childhood emotional and behaviour problems and specific psychotic experiences in a community sample of adolescents.

    Science.gov (United States)

    Shakoor, Sania; McGuire, Philip; Cardno, Alastair G; Freeman, Daniel; Ronald, Angelica

    2018-05-01

    Childhood emotional and behaviour problems are antecedents for later psychopathology. This study investigated genetic and environmental influences shaping the longitudinal association between childhood emotional and behaviour problems and specific PEs. In a community-based twin sample, parents reported on emotional and behaviour problems when twins were ages 7 and 12 years. At age 16 years, specific PEs were measured using self-reports and parent reports. Structural equation model-fitting was conducted. Childhood emotional and behaviour problems were significantly associated with paranoia, cognitive disorganisation and parent-rated negative symptoms in adolescence (mean r = .15-.38), and to a lesser extent with hallucinations, grandiosity and anhedonia (mean r = .04-.12). Genetic influences on childhood emotional and behaviour problems explained significant proportions of variance in adolescent paranoia (4%), cognitive disorganisation (8%) and parent-rated negative symptoms (3%). Unique environmental influences on childhood emotional and behaviour problems explained ≤1% of variance in PEs. Common environmental influences were only relevant for the relationship between childhood emotional and behaviour problems and parent-rated negative symptoms (explaining 28% of variance) and are partly due to correlated rater effects. Childhood emotional and behaviour problems are significantly, if weakly, associated with adolescent PEs. These associations are driven in part by common genetic influences underlying both emotional and behaviour problems and PEs. However, psychotic experiences in adolescence are largely influenced by genetic and environmental factors that are independent of general childhood emotional and behaviour problems, suggesting they are not merely an extension of childhood emotional and behaviour problems. © 2017 The Authors. Journal of Child Psychology and Psychiatry published by John Wiley & Sons Ltd on behalf of Association for Child and

  16. Serious diabetes-specific emotional problems and depression in a Croatian-Dutch-English Survey from the European Depression in Diabetes [EDID] Research Consortium

    DEFF Research Database (Denmark)

    Pouwer, Francois; Skinner, Timothy Chas; Pibernik-Okanovic, Mirjana

    2005-01-01

    for Epidemiological Studies Depression and the Problem Areas in Diabetes scales. Percentages of patients with high depression scores were: 39 and 34% (Croatian men and women), 19 and 21% (Dutch men and women), 19 and 39% (English men and women). Moreover, 79% (Croatian), 47% (Dutch) and 41% (English) of the patients......It has been hypothesized that coverage of diabetes-specific issues (e.g. coping with complications, incapacity, pain) during psychotherapy may optimize the likelihood of treatment success for depression in patients with diabetes. However, it is still unclear how often depression is confounded...... by diabetes-specific emotional problems. We aim to determine the levels of diabetes-specific emotional problems in diabetic individuals with high versus low levels of depression in a sample of 539 outpatients with diabetes (202 Dutch, 185 Croatian and 152 English). Subjects completed the Center...

  17. Mental health problems in pre-school children with specific language impairment: Use of the Strengths and Difficulties Questionnaire

    NARCIS (Netherlands)

    Flapper, B.C.; Bos, A.C.; Jansen, D.E.

    2011-01-01

    The prevalence of mental health problems (MHP) in children with language disorders ranges from 11 to 55%, due to additional disabilities that have a significant relationship to psychosocial difficulties. Specialists assume that children with a selective disorder [selective language impairment

  18. Simulation and calibration of the specific energy loss of the central jet chambers of the H1 detector and measurement of the inclusive D{sup *{+-}} meson cross section in photoproduction at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Hennekemper, Eva

    2011-12-15

    In this thesis the photoproduction of D{sup *} mesons in ep collisions at HERA is analysed. D{sup *} mesons are detected in the 'golden' decay channel D{sup *} {yields} K{pi}{pi}{sub s} with the H1 detector. Compared to earlier analyses, the systematic uncertainty is reduced due to two main improvements. Firstly, the simulation of the Fast Track Trigger, which is based on tracks measured within the central jet chambers, allows the trigger efficiency dependence of various kinematic variables to be evaluated. Secondly, the use of specific energy loss provides the possibility to suppress the non-resonant background. In order to use particle identification with the specific energy loss in the analysis, the simulation of the specific energy loss in the central jet chambers of the H1 detector is improved and the necessary correction functions and calibrations have been determined. This improved final H1 detector simulation is used to determine the cross section of photoproduction of D{sup *} mesons in the HERA II data sample, which corresponds to an integrated luminosity of 113 pb{sup -1}. The measurement was performed in the kinematic region of Q{sup 2}<2 GeV for the photon virtuality and photon-proton center of mass energies of 100

  19. Energy calibration of a multilayer photon detector

    International Nuclear Information System (INIS)

    Johnson, R.A.

    1983-01-01

    The job of energy calibration was broken into three parts: gain normalization of all equivalent elements; determination of the functions for conversion of pulse height to energy; and gain stabilization. It is found that calorimeter experiments are no better than their calibration systems - calibration errors will be the major source of error at high energies. Redundance is found to be necessary - the system should be designed such that every element could be replaced during the life of the experiment. It is found to be important to have enough data taken during calibration runs and during the experiment to be able to sort out where the calibration problems were after the experiment is over. Each layer was normalized independently with electrons, and then the pulse height to energy conversion was determined with photons. The primary method of gain stabilization used the light flasher system

  20. Specific treatment of problems of the spine (STOPS: design of a randomised controlled trial comparing specific physiotherapy versus advice for people with subacute low back disorders

    Directory of Open Access Journals (Sweden)

    Richards Matthew C

    2011-05-01

    Full Text Available Abstract Background Low back disorders are a common and costly cause of pain and activity limitation in adults. Few treatment options have demonstrated clinically meaningful benefits apart from advice which is recommended in all international guidelines. Clinical heterogeneity of participants in clinical trials is hypothesised as reducing the likelihood of demonstrating treatment effects, and sampling of more homogenous subgroups is recommended. We propose five subgroups that allow the delivery of specific physiotherapy treatment targeting the pathoanatomical, neurophysiological and psychosocial components of low back disorders. The aim of this article is to describe the methodology of a randomised controlled trial comparing specific physiotherapy treatment to advice for people classified into five subacute low back disorder subgroups. Methods/Design A multi-centre parallel group randomised controlled trial is proposed. A minimum of 250 participants with subacute (6 weeks to 6 months low back pain and/or referred leg pain will be classified into one of five subgroups and then randomly allocated to receive either physiotherapy advice (2 sessions over 10 weeks or specific physiotherapy treatment (10 sessions over 10 weeks tailored according to the subgroup of the participant. Outcomes will be assessed at 5 weeks, 10 weeks, 6 months and 12 months following randomisation. Primary outcomes will be activity limitation measured with a modified Oswestry Disability Index as well as leg and back pain intensity measured on separate 0-10 Numerical Rating Scales. Secondary outcomes will include a 7-point global rating of change scale, satisfaction with physiotherapy treatment, satisfaction with treatment results, the Sciatica Frequency and Bothersomeness Scale, quality of life (EuroQol-5D, interference with work, and psychosocial risk factors (Orebro Musculoskeletal Pain Questionnaire. Adverse events and co-interventions will also be measured. Data will be

  1. Calibration of a stochastic health evolution model using NHIS data

    Science.gov (United States)

    Gupta, Aparna; Li, Zhisheng

    2011-10-01

    This paper presents and calibrates an individual's stochastic health evolution model. In this health evolution model, the uncertainty of health incidents is described by a stochastic process with a finite number of possible outcomes. We construct a comprehensive health status index (HSI) to describe an individual's health status, as well as a health risk factor system (RFS) to classify individuals into different risk groups. Based on the maximum likelihood estimation (MLE) method and the method of nonlinear least squares fitting, model calibration is formulated in terms of two mixed-integer nonlinear optimization problems. Using the National Health Interview Survey (NHIS) data, the model is calibrated for specific risk groups. Longitudinal data from the Health and Retirement Study (HRS) is used to validate the calibrated model, which displays good validation properties. The end goal of this paper is to provide a model and methodology, whose output can serve as a crucial component of decision support for strategic planning of health related financing and risk management.

  2. Outcomes of specific interpersonal problems for binge eating disorder: comparing group psychodynamic interpersonal psychotherapy and group cognitive behavioral therapy.

    Science.gov (United States)

    Tasca, Giorgio A; Balfour, Louise; Presniak, Michelle D; Bissada, Hany

    2012-04-01

    We assessed whether an attachment-based treatment, Group Psychodynamic Interpersonal Psychotherapy (GPIP) had a greater impact compared to Group Cognitive Behavioral Therapy (GCBT) on Cold/Distant and Intrusive/Needy interpersonal problems. Ninety-five individuals with Binge Eating Disorder (BED) were randomized to GPIP or GCBT and assessed at pre-, post-, and six months post-treatment. Both therapies resulted in a significant decrease in all eight interpersonal problem subscales except the Nonassertive subscale. GPIP resulted in a greater reduction in the Cold/Distant subscale compared to GCBT, but no differences were found for changes in the Intrusive/Needy subscale. GPIP may be most relevant for those with BED who have Cold/Distant interpersonal problems and attachment avoidance.

  3. An Examination of Specific Child Behavior Problems as Predictors of Parenting Stress among Families of Children with Pervasive Developmental Disorders

    Science.gov (United States)

    Davis, Allyson L.; Neece, Cameron L.

    2017-01-01

    Introduction: Studies have shown that parents of children with pervasive developmental disorders (PDD) exhibit higher levels of stress than parents of typically developing children or children with other types of developmental delays (DD). This relationship appears to be mediated by elevated levels of behavior problems observed in children with…

  4. Transportation Problems in Special Education Programs in Rural Areas - A Specific Solution and Some Suggestions for Delivery System Development.

    Science.gov (United States)

    Brody, Z. H.

    The paper describes transportation problems encountered and solutions employed in delivering systems of comprehensive services to handicapped children in Anderson County, Tennessee, a predominantly rural area with considerable mountain area. Detailed are methods of transportation utilized in the four different program areas of the county special…

  5. Effect of routine assessment of specific psychosocial problems on personalized communication, counselors' awareness, and distress levels in cancer genetic counseling practice: a randomized controlled trial

    NARCIS (Netherlands)

    Eijzenga, W.; Aaronson, N.K.; Hahn, D.E.E.; Sidharta, G.N.; van der Kolk, L.E.; Velthuizen, M.E.; Ausems, M.G.E.M.; Bleiker, E.M.A.

    2014-01-01

    Purpose: This study evaluated the efficacy of a cancer genetics-specific questionnaire in facilitating communication about, awareness of, and management of psychosocial problems, as well as in lowering distress levels. Methods: Individuals referred to genetic counseling for cancer at two family

  6. RF impedance measurement calibration

    International Nuclear Information System (INIS)

    Matthews, P.J.; Song, J.J.

    1993-01-01

    The intent of this note is not to explain all of the available calibration methods in detail. Instead, we will focus on the calibration methods of interest for RF impedance coupling measurements and attempt to explain: (1). The standards and measurements necessary for the various calibration techniques. (2). The advantages and disadvantages of each technique. (3). The mathematical manipulations that need to be applied to the measured standards and devices. (4). An outline of the steps needed for writing a calibration routine that operated from a remote computer. For further details of the various techniques presented in this note, the reader should consult the references

  7. Satellite imager calibration and validation

    CSIR Research Space (South Africa)

    Vhengani, L

    2010-10-01

    Full Text Available and Validation Lufuno Vhengani*, Minette Lubbe, Derek Griffith and Meena Lysko Council for Scientific and Industrial Research, Defence Peace Safety and Security, Pretoria, South Africa E-mail: * lvhengani@csir.co.za Abstract: The success or failure... techniques specific to South Africa. 1. Introduction The success or failure of any earth observation mission depends on the quality of its data. To achieve optimum levels of reliability most sensors are calibrated pre-launch. However...

  8. Parental alcohol use, alcohol-related problems, and alcohol-specific attitudes, alcohol-specific communication, and adolescent excessive alcohol use and alcohol-related problems: An indirect path model

    NARCIS (Netherlands)

    Mares, S.H.W.; Vorst, H. van der; Engels, R.C.M.E.; Lichtwarck-Aschoff, A.

    2011-01-01

    Alcohol-specific parent-child communication has often been studied in relation to regular alcohol use of adolescents. However, it might be as important to focus on adolescent problematic alcohol use. In addition, the way parents communicate with their children about alcohol might depend on their own

  9. Calibration-free optical chemical sensors

    Science.gov (United States)

    DeGrandpre, Michael D.

    2006-04-11

    An apparatus and method for taking absorbance-based chemical measurements are described. In a specific embodiment, an indicator-based pCO2 (partial pressure of CO2) sensor displays sensor-to-sensor reproducibility and measurement stability. These qualities are achieved by: 1) renewing the sensing solution, 2) allowing the sensing solution to reach equilibrium with the analyte, and 3) calculating the response from a ratio of the indicator solution absorbances which are determined relative to a blank solution. Careful solution preparation, wavelength calibration, and stray light rejection also contribute to this calibration-free system. Three pCO2 sensors were calibrated and each had response curves which were essentially identical within the uncertainty of the calibration. Long-term laboratory and field studies showed the response had no drift over extended periods (months). The theoretical response, determined from thermodynamic characterization of the indicator solution, also predicted the observed calibration-free performance.

  10. CERN Radiation Protection (RP) calibration facilities

    CERN Document Server

    AUTHOR|(CDS)2082069; Macián-Juan, Rafael

    Radiation protection calibration facilities are essential to ensure the correct operation of radiation protection instrumentation. Calibrations are performed in specific radiation fields according to the type of instrument to be calibrated: neutrons, photons, X-rays, beta and alpha particles. Some of the instruments are also tested in mixed radiation fields as often encountered close to high-energy particle accelerators. Moreover, calibration facilities are of great importance to evaluate the performance of prototype detectors; testing and measuring the response of a prototype detector to well-known and -characterized radiation fields contributes to improving and optimizing its design and capabilities. The CERN Radiation Protection group is in charge of performing the regular calibrations of all CERN radiation protection devices; these include operational and passive dosimeters, neutron and photon survey-meters, and fixed radiation detectors to monitor the ambient dose equivalent, H*(10), inside CERN accelera...

  11. Bayesian calibration : past achievements and future challenges

    International Nuclear Information System (INIS)

    Christen, J.A.

    2001-01-01

    Due to variations of the radiocarbon content in the biosphere over time, radiocarbon determinations need to be calibrated to obtain calendar years. Over the past decade a series of researchers have investigated the possibility of using Bayesian statistics to calibrate radiocarbon determinations, the main feature being the inclusion of contextual information into the calibration process. This allows for a coherent calibration of groups of determinations arising from related contexts (stratigraphical layers, peat cores, cultural events, ect.). Moreover, the 'related contexts' are also dated, and not only the material radiocarbon dated itself. We review Bayesian Calibration and state some of its current challenges like: software development, prior specification, robustness, etc. (author). 14 refs., 4 figs

  12. Direct illumination LED calibration for telescope photometry

    International Nuclear Information System (INIS)

    Barrelet, E.; Juramy, C.

    2008-01-01

    A calibration method for telescope photometry, based on the direct illumination of a telescope with a calibrated light source regrouping multiple LEDs, is proposed. Its purpose is to calibrate the instrument response. The main emphasis of the proposed method is the traceability of the calibration process and a continuous monitoring of the instrument in order to maintain a 0.2% accuracy over a period of years. Its specificity is to map finely the response of the telescope and its camera as a function of all light ray parameters. This feature is essential to implement a computer model of the instrument representing the variation of the overall light collection efficiency of each pixel for various filter configurations. We report on hardware developments done for SNDICE, the first application of this direct illumination calibration system which will be installed in Canada France Hawaii telescope (CFHT) for its leading supernova experiment (SNLS)

  13. Calibration method of radiation monitoring system at TQNPC

    International Nuclear Information System (INIS)

    Liu Zhengshan; Zhang Qingli; Liu Jinjin; Miao Yuxing; Geng Lixin; Zhuang Yun; Dong Jianfeng; He Change

    2009-04-01

    The calibration methods and calibration device for standard monitor of radioactive particulate, iodine, noble gas and so on are not yet set up at home. On consideration of the present situation of the radiation monitoring system at the Third Qinshan Nuclear Power Co. Ltd., we have studied the calibration method of these radiation monitoring instruments used for measuring the waste liquid, particulate, iodine and noble gas produced during the operation of nuclear reactor. Through the check against these instruments during the No. 202 and No. 103 overhaul, we got initially the method of the calibration and obtained the transfer coefficient of calibration when secondary solid sources are used for calibration. Through the testing and calibration, the credibility of the radiation monitoring system is enhanced. And at the same time, the problems existing in the calibration are discussed. (authors)

  14. Autobiographical memory specificity and the persistence of depressive symptoms in HIV-positive patients: rumination and social problem-solving skills as mediators.

    Science.gov (United States)

    Yanes, Paula K; Morse, Gene; Hsiao, Chiu-Bin; Simms, Leonard; Roberts, John E

    2012-01-01

    Individuals infected with human immunodeficiency virus (HIV) are at elevated risk for depressive conditions, which in turn can negatively impact health-related behaviours and the course of illness. The present study tested the role of autobiographical memory specificity and its interaction with perceived stress in the persistence of depressive symptoms among dysphoric HIV-positive individuals. Additionally, we examined whether rumination and social problem solving mediated these effects. Results indicated that memory specificity moderated the impact of perceived stress, such that perceived stress was more strongly associated with follow-up depressive symptoms among those with greater memory specificity. Rumination, but not social problem solving, mediated this effect. Implications of these findings are discussed.

  15. Effect of routine assessment of specific psychosocial problems on personalized communication, counselors’ awareness, and distress levels in cancer genetic counseling practice: a randomized controlled trial.

    Science.gov (United States)

    Eijzenga, Willem; Aaronson, Neil K; Hahn, Daniela E E; Sidharta, Grace N; van der Kolk, Lizet E; Velthuizen, Mary E; Ausems, Margreet G E M; Bleiker, Eveline M A

    2014-09-20

    This study evaluated the efficacy of a cancer genetics–specific questionnaire in facilitating communication about, awareness of, and management of psychosocial problems, as well as in lowering distress levels. Individuals referred to genetic counseling for cancer at two family cancer clinics in The Netherlands were randomly assigned to an intervention or a control group. All participants completed the psychosocial questionnaire before counseling. In the intervention group, the counselors received the results of this questionnaire before the counseling session. All sessions were audiotaped for content analysis. Primary outcomes were the frequency with which psychosocial problems were discussed, the genetic counselors’ awareness of these problems, and their management. Secondary outcomes included cancer worries and psychological distress, duration and dynamics of the counseling, and satisfaction. The frequency with which psychosocial problems were discussed with 246 participating counselees was significantly higher in the intervention group (n = 127) than in the control group (n =119; P = .004), as was the counselors’ awareness of psychosocial problems regarding hereditary predisposition (P cancer (P = .01), and general emotions (P cancer worries (p = .005) and distress (p = .02) after counseling. The routine assessment of psychosocial problems by questionnaire facilitates genetic counselors’ recognition and discussion of their clients’ psychosocial problems and reduces clients’ distress levels.

  16. [Medical surveillance in university: organizational difficulties, legal problems, scientific e technical specificities. Experience of University of Milan Bicocca].

    Science.gov (United States)

    D'Orso, M I; Giuliani, C; Assini, R; Riva, M A; Cesana, G

    2012-01-01

    Our research describes activities of Occupational Health carried out during last year in University of Milan Bicocca by Occupational Doctors. We describe results of medical surveillance in 1153 employees or students exposed to occupational risks for health and safety. We report results obtained, technical difficulties, organizational problems, and preventive actions decided to improve functionality of our activity. Students seem to be less protected and consequently seem to have higher professional safety and health risks.

  17. The coal. Its place in the world, the specifical problems of the european countries and more particularly the France

    International Nuclear Information System (INIS)

    2001-12-01

    In a first part, the work group presents the available resources and studies the coal world market evolution. Then in a second time it discusses the european situation, and especially the french and german situation. The last part is devoted to the reconversion of the mines in France, the problems with the example of the coal basin of north of France. (A.L.B.)

  18. Validation of a densimeter calibration procedure for a secondary calibration laboratory

    International Nuclear Information System (INIS)

    Alpizar Herrera, Juan Carlos

    2014-01-01

    A survey was conducted to quantify the need for calibration of a density measurement instrument at the research units at the Sede Rodrigo Facio of the Universidad de Costa Rica. A calibration procedure was documented for the instrument that presented the highest demand in the survey by the calibration service. A study of INTE-ISO/IEC 17025: 2005 and specifically in section 5.4 of this standard was done, to document the procedure for calibrating densimeters. Densimeter calibration procedures and standards were sought from different national and international sources. The method of hydrostatic weighing or Cuckow method was the basis of the defined procedure. Documenting the calibration procedure and creating other documents was performed for data acquisition log, intermediate calculation log and calibration certificate copy. A veracity test was performed using as reference laboratory a laboratory of calibration secondary national as part of the validation process of the documented procedure. The results of the E_n statistic of 0.41; 0.34 and 0.46 for the calibration points 90%, 50% and 10% were obtained for the densimeter scale respectively. A reproducibility analysis of the method was performed with satisfactory results. Different suppliers were contacted to estimate the economic costs of the equipment and materials, needed to develop the documented method of densimeter calibration. The acquisition of an analytical balance was recommended, instead of a precision scale, in order to improve the results obtained with the documented method [es

  19. Calibration of moisture monitors

    International Nuclear Information System (INIS)

    Gutierrez, R.L.

    1979-02-01

    A method for calibrating an aluminum oxide hygrometer against an optical chilled mirror dew-point hygrometer has been established. A theoretical cross-point line of dew points from both hygrometers and a maximum moisture content of 10 ppM/sub v/ are used to define an area for calibrating the sensor probes of the aluminum oxide hygrometer

  20. Site Calibration report

    DEFF Research Database (Denmark)

    Yordanova, Ginka; Vesth, Allan

    The report describes site calibration measurements carried out on a site in Denmark. The measurements are carried out in accordance to Ref. [1]. The site calibration is carried out before a power performance measurement on a given turbine to clarify the influence from the terrain on the ratio...

  1. COMPARISON OF METHODS FOR GEOMETRIC CAMERA CALIBRATION

    Directory of Open Access Journals (Sweden)

    J. Hieronymus

    2012-09-01

    Full Text Available Methods for geometric calibration of cameras in close-range photogrammetry are established and well investigated. The most common one is based on test-fields with well-known pattern, which are observed from different directions. The parameters of a distortion model are calculated using bundle-block-adjustment-algorithms. This methods works well for short focal lengths, but is essentially more problematic to use with large focal lengths. Those would require very large test-fields and surrounding space. To overcome this problem, there is another common method for calibration used in remote sensing. It employs measurements using collimator and a goniometer. A third calibration method uses diffractive optical elements (DOE to project holograms of well known pattern. In this paper these three calibration methods are compared empirically, especially in terms of accuracy. A camera has been calibrated with those methods mentioned above. All methods provide a set of distortion correction parameters as used by the photogrammetric software Australis. The resulting parameter values are very similar for all investigated methods. The three sets of distortion parameters are crosscompared against all three calibration methods. This is achieved by inserting the gained distortion parameters as fixed input into the calibration algorithms and only adjusting the exterior orientation. The RMS (root mean square of the remaining image coordinate residuals are taken as a measure of distortion correction quality. There are differences resulting from the different calibration methods. Nevertheless the measure is small for every comparison, which means that all three calibration methods can be used for accurate geometric calibration.

  2. Design of problem-specific evolutionary algorithm/mixed-integer programming hybrids: two-stage stochastic integer programming applied to chemical batch scheduling

    Science.gov (United States)

    Urselmann, Maren; Emmerich, Michael T. M.; Till, Jochen; Sand, Guido; Engell, Sebastian

    2007-07-01

    Engineering optimization often deals with large, mixed-integer search spaces with a rigid structure due to the presence of a large number of constraints. Metaheuristics, such as evolutionary algorithms (EAs), are frequently suggested as solution algorithms in such cases. In order to exploit the full potential of these algorithms, it is important to choose an adequate representation of the search space and to integrate expert-knowledge into the stochastic search operators, without adding unnecessary bias to the search. Moreover, hybridisation with mathematical programming techniques such as mixed-integer programming (MIP) based on a problem decomposition can be considered for improving algorithmic performance. In order to design problem-specific EAs it is desirable to have a set of design guidelines that specify properties of search operators and representations. Recently, a set of guidelines has been proposed that gives rise to so-called Metric-based EAs (MBEAs). Extended by the minimal moves mutation they allow for a generalization of EA with self-adaptive mutation strength in discrete search spaces. In this article, a problem-specific EA for process engineering task is designed, following the MBEA guidelines and minimal moves mutation. On the background of the application, the usefulness of the design framework is discussed, and further extensions and corrections proposed. As a case-study, a two-stage stochastic programming problem in chemical batch process scheduling is considered. The algorithm design problem can be viewed as the choice of a hierarchical decision structure, where on different layers of the decision process symmetries and similarities can be exploited for the design of minimal moves. After a discussion of the design approach and its instantiation for the case-study, the resulting problem-specific EA/MIP is compared to a straightforward application of a canonical EA/MIP and to a monolithic mathematical programming algorithm. In view of the

  3. Sandia WIPP calibration traceability

    Energy Technology Data Exchange (ETDEWEB)

    Schuhen, M.D. [Sandia National Labs., Albuquerque, NM (United States); Dean, T.A. [RE/SPEC, Inc., Albuquerque, NM (United States)

    1996-05-01

    This report summarizes the work performed to establish calibration traceability for the instrumentation used by Sandia National Laboratories at the Waste Isolation Pilot Plant (WIPP) during testing from 1980-1985. Identifying the calibration traceability is an important part of establishing a pedigree for the data and is part of the qualification of existing data. In general, the requirement states that the calibration of Measuring and Test equipment must have a valid relationship to nationally recognized standards or the basis for the calibration must be documented. Sandia recognized that just establishing calibration traceability would not necessarily mean that all QA requirements were met during the certification of test instrumentation. To address this concern, the assessment was expanded to include various activities.

  4. The GERDA calibration system

    Energy Technology Data Exchange (ETDEWEB)

    Baudis, Laura; Froborg, Francis; Tarka, Michael; Bruch, Tobias; Ferella, Alfredo [Physik-Institut, Universitaet Zuerich (Switzerland); Collaboration: GERDA-Collaboration

    2012-07-01

    A system with three identical custom made units is used for the energy calibration of the GERDA Ge diodes. To perform a calibration the {sup 228}Th sources are lowered from the parking positions at the top of the cryostat. Their positions are measured by two independent modules. One, the incremental encoder, counts the holes in the perforated steel band holding the sources, the other measures the drive shaft's angular position even if not powered. The system can be controlled remotely by a Labview program. The calibration data is analyzed by an iterative calibration algorithm determining the calibration functions for different energy reconstruction algorithms and the resolution of several peaks in the {sup 228}Th spectrum is determined. A Monte Carlo simulation using the GERDA simulation software MAGE has been performed to determine the background induced by the sources in the parking positions.

  5. Sandia WIPP calibration traceability

    International Nuclear Information System (INIS)

    Schuhen, M.D.; Dean, T.A.

    1996-05-01

    This report summarizes the work performed to establish calibration traceability for the instrumentation used by Sandia National Laboratories at the Waste Isolation Pilot Plant (WIPP) during testing from 1980-1985. Identifying the calibration traceability is an important part of establishing a pedigree for the data and is part of the qualification of existing data. In general, the requirement states that the calibration of Measuring and Test equipment must have a valid relationship to nationally recognized standards or the basis for the calibration must be documented. Sandia recognized that just establishing calibration traceability would not necessarily mean that all QA requirements were met during the certification of test instrumentation. To address this concern, the assessment was expanded to include various activities

  6. Cognitive-Behavioral Treatment for Specific Phobias with a Child Demonstrating Severe Problem Behavior and Developmental Delays

    Science.gov (United States)

    Davis, Thompson E., III; Kurtz, Patricia F.; Gardner, Andrew W.; Carman, Nicole B.

    2007-01-01

    Cognitive-behavioral treatments (CBTs) are widely used for anxiety disorders in typically developing children; however, there has been no previous attempt to administer CBT for specific phobia (in this case study, one-session treatment) to developmentally or intellectually disabled children. This case study integrates both cognitive-behavioral and…

  7. Radiometric Calibration of Osmi Imagery Using Solar Calibration

    Directory of Open Access Journals (Sweden)

    Dong-Han Lee

    2000-12-01

    Full Text Available OSMI (Ocean Scanning Multi-Spectral Imager raw image data (Level 0 were acquired and radiometrically corrected. We have applied two methods, using solar & dark calibration data from OSMI sensor and comparing with the SeaWiFS data, to the radiometric correction of OSMI raw image data. First, we could get the values of the gain and the offset for each pixel and each band from comparing the solar & dark calibration data with the solar input radiance values, calculated from the transmittance, BRDF (Bidirectional Reflectance Distribution Function and the solar incidence angle (¥â,¥è of OSMI sensor. Applying this calibration data to OSMI raw image data, we got the two odd results, the lower value of the radiometric corrected image data than the expected value, and the Venetian Blind Effect in the radiometric corrected image data. Second, we could get the reasonable results from comparing OSMI raw image data with the SeaWiFS data, and get a new problem of OSMI sensor.

  8. Calibration Laboratory of the Paul Scherrer Institute

    International Nuclear Information System (INIS)

    Gmuer, K.; Wernli, C.

    1994-01-01

    Calibration and working checks of radiation protection instruments are carried out at the Calibration Laboratory of the Paul Scherrer Institute. In view of the new radiation protection regulation, the calibration laboratory received an official federal status. The accreditation procedure in cooperation with the Federal Office of Metrology enabled a critical review of the techniques and methods applied. Specifically, personal responsibilities, time intervals for recalibration of standard instruments, maximum permissible errors of verification, traceability and accuracy of the standard instruments, form and content of the certificates were defined, and the traceability of the standards and quality assurance were reconsidered. (orig.) [de

  9. Review of Calibration Methods for Scheimpflug Camera

    Directory of Open Access Journals (Sweden)

    Cong Sun

    2018-01-01

    Full Text Available The Scheimpflug camera offers a wide range of applications in the field of typical close-range photogrammetry, particle image velocity, and digital image correlation due to the fact that the depth-of-view of Scheimpflug camera can be greatly extended according to the Scheimpflug condition. Yet, the conventional calibration methods are not applicable in this case because the assumptions used by classical calibration methodologies are not valid anymore for cameras undergoing Scheimpflug condition. Therefore, various methods have been investigated to solve the problem over the last few years. However, no comprehensive review exists that provides an insight into recent calibration methods of Scheimpflug cameras. This paper presents a survey of recent calibration methods of Scheimpflug cameras with perspective lens, including the general nonparametric imaging model, and analyzes in detail the advantages and drawbacks of the mainstream calibration models with respect to each other. Real data experiments including calibrations, reconstructions, and measurements are performed to assess the performance of the models. The results reveal that the accuracies of the RMM, PLVM, PCIM, and GNIM are basically equal, while the accuracy of GNIM is slightly lower compared with the other three parametric models. Moreover, the experimental results reveal that the parameters of the tangential distortion are likely coupled with the tilt angle of the sensor in Scheimpflug calibration models. The work of this paper lays the foundation of further research of Scheimpflug cameras.

  10. Quality control for dose calibrators

    International Nuclear Information System (INIS)

    Mendes, L.C.G.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are accomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintillation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (author)

  11. Procedures for calibration of brachytherapy sources

    International Nuclear Information System (INIS)

    Alfonso Laguardia, R.; Alonso Samper, J.L.; Morales Lopez, J.L.; Saez Nunez, D.G.

    1997-01-01

    Brachytherapy source strength verification is a responsibility of the user of these source, in fact of the Medical Physicists in charge of this issue in a Radiotherapy Service. The calibration procedures in the users conditions are shown. Specifics methods for source strength determination are recommended, both for High Dose Rate (HDR) sources with Remote Afterloading equipment and for Low Dose Rate sources. The The results of the calibration of HDR Remote After loaders are indicated

  12. Calibrating the neutron moisture meter: Precision and economy

    International Nuclear Information System (INIS)

    Akhter, J.; Waheed, R.A.; Hignett, C.T.; Greacen, E.L.

    2000-01-01

    Established laboratory and field calibration procedures for the neutron moisture meter are demonstrated on a uniform soil and alternative, low cost procedures on a duplex, less uniform soil. The effect of field variability on the calibration methodology is discussed with the aim of optimising calibration reliability at minimal cost. The difference between calibration for a soil material, or for a field (a range of soil materials) is considered. In particular, calibration for the estimation of water content change is shown to be a different problem from calibration for the estimation of water content in a variable field. Techniques aimed at detecting field variability problems during calibration are suggested, and methods for optimising the results for the intended use of the instrument are outlined. Pairing of calibration tubes, alternative methods of analysis of calibration data, and use of other information from the field to measure its variability, can improve the precision of calibration procedures to the point where minimal calibration effort, with careful analysis, can provide reliable results. (author)

  13. Specification of Change Mechanisms in Pregnant Smokers for Malleable Target Identification: A Novel Approach to a Tenacious Public Health Problem

    Directory of Open Access Journals (Sweden)

    Suena H. Massey

    2017-09-01

    Full Text Available Maternal smoking during pregnancy (MSDP continues to be a leading modifiable risk factor for perinatal complications and a range of neurodevelopmental and cardio-metabolic outcomes across the lifespan. Despite 40 years of intervention research less than one in five pregnant smokers who receive an intervention quit by delivery. Within this context, recognition of pregnancy is commonly associated with abrupt suspension or reduction of smoking in the absence of intervention, yet has not been investigated as a volitional target. The goal of this article is to provide the empirical foundation for a novel direction of research aimed at identifying malleable targets for intervention through the specification of behavior change mechanisms specific to pregnant women. To do so, we: (1 summarize progress on MSDP in the United States generated from conventional empirical approaches to health behavior change; (2 discuss the phenomenon of spontaneous change in the absence of intervention among pregnant smokers to illustrate the need for mechanistic specification of behavior change motivated by concern for fetal well-being; (3 summarize component processes in neurobiological models of parental and non-parental social behaviors as a conceptual framework for understanding change mechanisms during pregnancy; (4 discuss the evidence for the malleability of these processes to support their translational relevance for preventive interventions; and (5 propose a roadmap for validating the proposed change mechanism using an experimental medicine approach. A greater understanding of social and interpersonal processes that facilitate health behavior change among expectant mothers and how these processes differ interindividually could yield novel volitional targets for prenatal interventions. More broadly, explicating other-oriented mechanisms of behavior change during pregnancy could serve as a paradigm for understanding how social and interpersonal processes

  14. Compact radiometric microwave calibrator

    International Nuclear Information System (INIS)

    Fixsen, D. J.; Wollack, E. J.; Kogut, A.; Limon, M.; Mirel, P.; Singal, J.; Fixsen, S. M.

    2006-01-01

    The calibration methods for the ARCADE II instrument are described and the accuracy estimated. The Steelcast coated aluminum cones which comprise the calibrator have a low reflection while maintaining 94% of the absorber volume within 5 mK of the base temperature (modeled). The calibrator demonstrates an absorber with the active part less than one wavelength thick and only marginally larger than the mouth of the largest horn and yet black (less than -40 dB or 0.01% reflection) over five octaves in frequency

  15. Lidar to lidar calibration

    DEFF Research Database (Denmark)

    Fernandez Garcia, Sergio; Villanueva, Héctor

    This report presents the result of the lidar to lidar calibration performed for ground-based lidar. Calibration is here understood as the establishment of a relation between the reference lidar wind speed measurements with measurement uncertainties provided by measurement standard and corresponding...... lidar wind speed indications with associated measurement uncertainties. The lidar calibration concerns the 10 minute mean wind speed measurements. The comparison of the lidar measurements of the wind direction with that from the reference lidar measurements are given for information only....

  16. Potential or problem? An investigation of secondary school teachers' attributions of the educational outcomes of students with specific learning difficulties.

    Science.gov (United States)

    Woodcock, Stuart; Hitches, Elizabeth

    2017-10-01

    Despite strong support for inclusive education in principle, many teachers and administrators still demonstrate mixed responses to the inclusion of certain students in their classrooms. Students with specific learning difficulties (SpLD) form a large group of students in inclusive classrooms yet some provincial, state and national jurisdictions fail to acknowledge the existence of these students. Not acknowledging and understanding these students can deny them the recognition and resources necessary for their genuine participation in education and, in turn, society. The aim of this study was to examine British in-service secondary teachers' attributional responses to students with and without specific learning difficulties. The participants included 122 British secondary school teachers who were surveyed in response to vignettes of hypothetical male students who had failed a class test. The study found that while teachers attributed more positive causes towards students without SpLD, they exhibited more negative causes towards students with SpLD. Teachers' causal attributional outcomes of students' level of achievement can impact upon the students' own attributions, with teachers' responses for students with SpLD having the potential to, unintentionally, influence students' own sense of self-efficacy and motivation. The paper concludes with a consideration of the implications of the research and recommendations for practice.

  17. [Evaluation of residual osteomuscular function using computerised movement analysis for building sector workers: specificity and technical problem].

    Science.gov (United States)

    D'Orso, M I; Centemeri, R; Latocca, R; Riva, M; Cesana, G

    2012-01-01

    Occupational Health Doctors active in building sector firms frequently have to evaluate residual workers' osteomuscular function in patients coming back to work after an accident happened during work time or free time. Definition of their specific individual work suitability is usually carried out utilizing semeiotic tests in which subjective evaluation of every single Medical Doctor is real important in definition of final results and this fact can cause legal controversies. In our research we describe the application of computerised movement analysis on 10 workers of building sector. In every patient examined this technical method has been able to study objectively the tridimensional ranges of motion of most important osteomuscular districts. The possibility to have an objective evaluation of residual osteomuscular function has a relevant importance both in definition of workers' work suitability at the moment in which they start again their activities and in possible future legal conflicts.

  18. Risk-based evaluation of technical specification problems at the La Salle County Nuclear Station: Final report

    International Nuclear Information System (INIS)

    Bizzak, D.J.; Trainer, J.E.; McClymont, A.S.

    1987-06-01

    Probabilistic risk assessment (PRA) methods are used to evaluate alternatives to existing requirements for three operationally burdensome technical specifications at La Salle Nuclear Station. The study employs a decision logic to minimize the detailed analysis necessary to show compliance with given acceptance criteria; in this case, no risk increase resulting from a proposed change. The analyses provide insights to choose from among alternative options. The SOCRATES computer code was used for the probabilistic analysis. Results support a change to less frequent diesel generator testing, eliminations of one reactor scram setpoint, and establishing an allowed out-of-service time for valves in a reactor scram system. In each case, the change would result in a safety improvement

  19. Air Data Calibration Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility is for low altitude subsonic altimeter system calibrations of air vehicles. Mission is a direct support of the AFFTC mission. Postflight data merge is...

  20. SRHA calibration curve

    Data.gov (United States)

    U.S. Environmental Protection Agency — an UV calibration curve for SRHA quantitation. This dataset is associated with the following publication: Chang, X., and D. Bouchard. Surfactant-Wrapped Multiwalled...

  1. BES online calibration system

    International Nuclear Information System (INIS)

    Zhang Bingyun; Li Xiaonan; Zhu Kejun; Zhang Jiawen; Gong Mingyu

    2003-01-01

    We constructed BES (Beijing Spectrometer) online calibration system to ensure the coherence of readout electronic channels due to huge data volume in high energy physics experiment. This paper describes the structure of hardware and software, and its characteristic and function

  2. Calibrated Properties Model

    International Nuclear Information System (INIS)

    Ahlers, C.F.; Liu, H.H.

    2001-01-01

    The purpose of this Analysis/Model Report (AMR) is to document the Calibrated Properties Model that provides calibrated parameter sets for unsaturated zone (UZ) flow and transport process models for the Yucca Mountain Site Characterization Project (YMP). This work was performed in accordance with the AMR Development Plan for U0035 Calibrated Properties Model REV00 (CRWMS M and O 1999c). These calibrated property sets include matrix and fracture parameters for the UZ Flow and Transport Model (UZ Model), drift seepage models, drift-scale and mountain-scale coupled-processes models, and Total System Performance Assessment (TSPA) models as well as Performance Assessment (PA) and other participating national laboratories and government agencies. These process models provide the necessary framework to test conceptual hypotheses of flow and transport at different scales and predict flow and transport behavior under a variety of climatic and thermal-loading conditions

  3. Calibrated Properties Model

    International Nuclear Information System (INIS)

    Ahlers, C.; Liu, H.

    2000-01-01

    The purpose of this Analysis/Model Report (AMR) is to document the Calibrated Properties Model that provides calibrated parameter sets for unsaturated zone (UZ) flow and transport process models for the Yucca Mountain Site Characterization Project (YMP). This work was performed in accordance with the ''AMR Development Plan for U0035 Calibrated Properties Model REV00. These calibrated property sets include matrix and fracture parameters for the UZ Flow and Transport Model (UZ Model), drift seepage models, drift-scale and mountain-scale coupled-processes models, and Total System Performance Assessment (TSPA) models as well as Performance Assessment (PA) and other participating national laboratories and government agencies. These process models provide the necessary framework to test conceptual hypotheses of flow and transport at different scales and predict flow and transport behavior under a variety of climatic and thermal-loading conditions

  4. SPOTS Calibration Example

    Directory of Open Access Journals (Sweden)

    Patterson E.

    2010-06-01

    Full Text Available The results are presented using the procedure outlined by the Standardisation Project for Optical Techniques of Strain measurement to calibrate a digital image correlation system. The process involves comparing the experimental data obtained with the optical measurement system to the theoretical values for a specially designed specimen. The standard states the criteria which must be met in order to achieve successful calibration, in addition to quantifying the measurement uncertainty in the system. The system was evaluated at three different displacement load levels, generating strain ranges from 289 µstrain to 2110 µstrain. At the 289 µstrain range, the calibration uncertainty was found to be 14.1 µstrain, and at the 2110 µstrain range it was found to be 28.9 µstrain. This calibration procedure was performed without painting a speckle pattern on the surface of the metal. Instead, the specimen surface was prepared using different grades of grit paper to produce the desired texture.

  5. Scanner calibration revisited

    Directory of Open Access Journals (Sweden)

    Pozhitkov Alexander E

    2010-07-01

    Full Text Available Abstract Background Calibration of a microarray scanner is critical for accurate interpretation of microarray results. Shi et al. (BMC Bioinformatics, 2005, 6, Art. No. S11 Suppl. 2. reported usage of a Full Moon BioSystems slide for calibration. Inspired by the Shi et al. work, we have calibrated microarray scanners in our previous research. We were puzzled however, that most of the signal intensities from a biological sample fell below the sensitivity threshold level determined by the calibration slide. This conundrum led us to re-investigate the quality of calibration provided by the Full Moon BioSystems slide as well as the accuracy of the analysis performed by Shi et al. Methods Signal intensities were recorded on three different microarray scanners at various photomultiplier gain levels using the same calibration slide from Full Moon BioSystems. Data analysis was conducted on raw signal intensities without normalization or transformation of any kind. Weighted least-squares method was used to fit the data. Results We found that initial analysis performed by Shi et al. did not take into account autofluorescence of the Full Moon BioSystems slide, which led to a grossly distorted microarray scanner response. Our analysis revealed that a power-law function, which is explicitly accounting for the slide autofluorescence, perfectly described a relationship between signal intensities and fluorophore quantities. Conclusions Microarray scanners respond in a much less distorted fashion than was reported by Shi et al. Full Moon BioSystems calibration slides are inadequate for performing calibration. We recommend against using these slides.

  6. Calibration of thermoluminiscent materials

    International Nuclear Information System (INIS)

    Bos, A.J.J.

    1989-07-01

    In this report the relation between exposure and absorbed radiation dose in various materials is represented, on the base of recent data. With the help of this a calibration procedure for thermoluminescent materials, adapted to the IRI radiation standard is still the exposure in rontgen. In switching to the air kerma standard the calibration procedure will have to be adapted. (author). 6 refs.; 4 tabs

  7. Exploring the Domain Specificity of Creativity in Children: The Relationship between a Non-Verbal Creative Production Test and Creative Problem-Solving Activities

    Directory of Open Access Journals (Sweden)

    Ahmed Mohamed

    2012-12-01

    Full Text Available AbstractIn this study, we explored whether creativity was domain specific or domain general. The relationships between students’ scores on three creative problem-solving activities (math, spa-tial artistic, and oral linguistic in the DIS-COVER assessment (Discovering Intellectual Strengths and Capabilities While Observing Varied Ethnic Responses and the TCT-DP (Test of Creative Thinking-Drawing Produc-tion, a non-verbal general measure of creativi-ty, were examined. The participants were 135 first and second graders from two schools in the Southwestern United States from linguisti-cally and culturally diverse backgrounds. Pearson correlations, canonical correlations, and multiple regression analyses were calcu-lated to describe the relationship between the TCT-DP and the three DISCOVER creative problem-solving activities. We found that crea-tivity has both domain-specific and domain-general aspects, but that the domain-specific component seemed more prominent. One im-plication of these results is that educators should consider assessing creativity in specific domains to place students in special programs for gifted students rather than relying only on domain-general measures of divergent think-ing or creativity.

  8. Improvement of gamma calibration procedures with commercial management software

    International Nuclear Information System (INIS)

    Lucena, Rodrigo F.; Potiens, Maria da Penha A.; Santos, Gelson P.; Vivolo, Vitor

    2007-01-01

    In this work, the gamma calibration procedure of the Instruments Calibration Laboratory (LCI) of the IPEN-CNEN-SP was improved with the use of the commercial management software Autolab TM from Automa Company. That software was adapted for our specific use in the calibration procedures. The evaluation of the uncertainties in gamma calibration protocol was improved by the LCI staff and yet the all worksheets and final calibration report lay-out was developed in commercial software like Excell TM and Word TM from Microsft TM . (author)

  9. Calibrating nacelle lidars

    Energy Technology Data Exchange (ETDEWEB)

    Courtney, M.

    2013-01-15

    Nacelle mounted, forward looking wind lidars are beginning to be used to provide reference wind speed measurements for the power performance testing of wind turbines. In such applications, a formal calibration procedure with a corresponding uncertainty assessment will be necessary. This report presents four concepts for performing such a nacelle lidar calibration. Of the four methods, two are found to be immediately relevant and are pursued in some detail. The first of these is a line of sight calibration method in which both lines of sight (for a two beam lidar) are individually calibrated by accurately aligning the beam to pass close to a reference wind speed sensor. A testing procedure is presented, reporting requirements outlined and the uncertainty of the method analysed. It is seen that the main limitation of the line of sight calibration method is the time required to obtain a representative distribution of radial wind speeds. An alternative method is to place the nacelle lidar on the ground and incline the beams upwards to bisect a mast equipped with reference instrumentation at a known height and range. This method will be easier and faster to implement and execute but the beam inclination introduces extra uncertainties. A procedure for conducting such a calibration is presented and initial indications of the uncertainties given. A discussion of the merits and weaknesses of the two methods is given together with some proposals for the next important steps to be taken in this work. (Author)

  10. Chaos, Consternation and CALIPSO Calibration: New Strategies for Calibrating the CALIOP 1064 nm Channel

    Science.gov (United States)

    Vaughan, Mark; Garnier, Anne; Liu, Zhaoyan; Josset, Damien; Hu, Yongxiang; Lee, Kam-Pui; Hunt, William; Vernier, Jean-Paul; Rodier, Sharon; Pelon, Jaques; hide

    2012-01-01

    The very low signal-to-noise ratios of the 1064 nm CALIOP molecular backscatter signal make it effectively impossible to employ the "clear air" normalization technique typically used to calibrate elastic back-scatter lidars. The CALIPSO mission has thus chosen to cross-calibrate their 1064 nm measurements with respect to the 532 nm data using the two-wavelength backscatter from cirrus clouds. In this paper we discuss several known issues in the version 3 CALIOP 1064 nm calibration procedure, and describe the strategies that will be employed in the version 4 data release to surmount these problems.

  11. Specific absorption rate variation in a brain phantom due to exposure by a 3G mobile phone: problems in dosimetry.

    Science.gov (United States)

    Behari, J; Nirala, Jay Prakash

    2013-12-01

    A specific absorption rate (SAR) measurements system has been developed for compliance testing of personal mobile phone in a brain phantom material contained in a Perspex box. The volume of the box has been chosen corresponding to the volume of a small rat and illuminated by a 3G mobile phone frequency (1718.5 MHz), and the emitted radiation directed toward brain phantom .The induced fields in the phantom material are measured. Set up to lift the plane carrying the mobile phone is run by a pulley whose motion is controlled by a stepper motor. The platform is made to move at a pre-determined rate of 2 degrees per min limited up to 20 degrees. The measured data for induced fields in various locations are used to compute corresponding SAR values and inter comparison obtained. These data are also compared with those when the mobile phone is placed horizontally with respect to the position of the animal. The SAR data is also experimentally obtained by measuring a rise in temperature due to this mobile exposures and data compared with those obtained in the previous set. To seek a comparison with the safety criteria same set of measurements are performed in 10 g phantom material contained in a cubical box. These results are higher than those obtained with the knowledge of induced field measurements. It is concluded that SAR values are sensitive to the angular position of the moving platform and are well below the safety criteria prescribed for human exposure. The data are suggestive of having a fresh look to understand the mode of electromagnetic field -bio interaction.

  12. The prevalence, incidence, and gender and age-specific incidence of problem gambling: results of the Swedish longitudinal gambling study (Swelogs).

    Science.gov (United States)

    Abbott, Max; Romild, Ulla; Volberg, Rachel

    2018-04-01

    To estimate the prevalence, incidence and gender and age-specific incidence of problem gambling in the Swedish adult population. Longitudinal cohort study with linkage to register data. Sweden. Stratified random sample aged 16-84 years at baseline (n = 8165) re-assessed a year later (n = 6021). Problem gambling (life-time and past 12 months) was measured by the South Oaks Gambling Screen-Revised (SOGS-R). Past 12-month (current) problem gambling was also measured by the Problem Gambling Severity Index (PGSI). The SOGS-R combined current pathological and problem gambling prevalence rate (PR) was 2.1 [95% confidence interval (CI) = 1.8-2.4] at baseline and 1.7 (1.4-2.0) at follow-up, approximately half the corresponding life-time estimates.[Correction added on 22 Dec 2017, after first online publication: In the preceding sentence, the SOGS-R combined current pathological and problem gambling prevalence rate (PR) was incorrectly reported as being double the corresponding life-time rate. It has been corrected in this version.] PGSI combined current problem and moderate-risk gambling PRs were 2.2 (1.9-2.5) at baseline and 1.9 (1.6-2.2) at follow-up. Combined incidence rates (IRs) were 1.0 (0.8-1.3) (SOGS-R) and 1.4 (1.1-1.7) (PGSI), with more than three-quarters being new cases. While first-time IRs did not vary by gender, males had a higher relapse IR and proportionately more females were new cases. The young adult IR was more than double the older adult IR; similar proportions were new cases. The actual incidence of problem gambling relapse in Sweden is likely to be higher than estimated. The profile of problem gambling in Sweden is likely to change over time, with increased proportions of women and older adults. © 2017 Society for the Study of Addiction.

  13. NICMOS Cycles 13 and 14 Calibration Plans

    Science.gov (United States)

    Arribas, Santiago; Bergeron, Eddie; de Jong, Roeof; Malhotra, Sangeeta; Mobasher, Bahram; Noll, Keith; Schultz, Al; Wiklind, Tommy; Xu, Chun

    2005-11-01

    This document summarizes the NICMOS Calibration Plans for Cycles 13 and 14. These plans complement the SMOV3b, the Cycle 10 (interim), and the Cycles 11 and 12 (regular) calibration programs executed after the installation of the NICMOS Cooling System (NCS).. These previous programs have shown that the instrument is very stable, which has motivated a further reduction in the frequency of the monitoring programs for Cycle 13. In addition, for Cycle 14 some of these programs were slightly modified to account for 2 Gyro HST operations. The special calibrations on Cycle 13 were focussed on a follow up of the spectroscopic recalibration initiated in Cycle 12. This program led to the discovery of a possible count rate non-linearity, which has triggered a special program for Cycle 13 and a number of subsequent tests and calibrations during Cycle 14. At the time of writing this is a very active area of research. We also briefly comment on other calibrations defined to address other specific issues like: the autoreset test, the SPAR sequences tests, and the low-frequency flat residual for NIC1. The calibration programs for the 2-Gyro campaigns are not included here, since they have been described somewhere else. Further details and updates on specific programs can be found via the NICMOS web site.

  14. The gender specific mediational pathways between parenting styles, neuroticism, pathological reasons for drinking, and alcohol-related problems in emerging adulthood.

    Science.gov (United States)

    Patock-Peckham, Julie A; Morgan-Lopez, Antonio A

    2009-03-01

    Mediational links between parenting styles, neuroticism, pathological reasons for drinking, alcohol use and alcohol-related problems were tested. A two-group SEM path model with 441 (216 female, 225 male) college students was examined. In general, pathological reasons for drinking mediated the impact of neuroticism on alcohol use and alcohol-related problems. A different pattern of relationships was found for each of the two genders. Perceptions of having an authoritarian father were positively linked to higher levels of neuroticism among males but this pattern was not found among females. For males, neuroticism mediated the impact of having an authoritarian father on pathological reasons for drinking with pathological reasons for drinking mediating the impact of neuroticism on alcohol-related problems. Perceptions of having a permissive father were linked to lower levels of neuroticism in females (but have been found as a consistent risk factor for other pathways to alcohol use elsewhere). Compared with other work in this area, these findings indicate parental influences regarding vulnerabilities for alcohol use may be specific to parent-child gender matches for some pathways and specific to one parent (irrespective of child gender) for other pathways.

  15. Commissioning the CMS alignment and calibration framework

    International Nuclear Information System (INIS)

    Futyan, David

    2010-01-01

    The CMS experiment has developed a powerful framework to ensure the precise and prompt alignment and calibration of its components, which is a major prerequisite to achieve the optimal performance for physics analysis. The prompt alignment and calibration strategy harnesses computing resources both at the Tier-0 site and the CERN Analysis Facility (CAF) to ensure fast turnaround for updating the corresponding database payloads. An essential element is the creation of dedicated data streams concentrating the specific event information required by the various alignment and calibration workflows. The resulting low latency is required for feeding the resulting constants into the prompt reconstruction process, which is essential for achieving swift physics analysis of the LHC data. This report discusses the implementation and the computational aspects of the alignment and calibration framework. Recent commissioning campaigns with cosmic muons, beam halo and simulated data have been used to gain detailed experience with this framework, and results of this validation are reported.

  16. Commissioning the CMS Alignment and Calibration Framework

    CERN Document Server

    Futyan, David

    2009-01-01

    The CMS experiment has developed a powerful framework to ensure the precise and prompt alignment and calibration of its components, which is a major prerequisite to achieve the optimal performance for physics analysis. The prompt alignment and calibration strategy harnesses computing resources both at the Tier-0 site and the CERN Analysis Facility (CAF) to ensure fast turnaround for updating the corresponding database payloads. An essential element is the creation of dedicated data streams concentrating the specific event information required by the various alignment and calibration workflows. The resulting low latency is required for feeding the resulting constants into the prompt reconstruction process, which is essential for achieving swift physics analysis of the LHC data. This report discusses the implementation and the computational aspects of the alignment and calibration framework. Recent commissioning campaigns with cosmic muons, beam halo and simulated data have been used to gain detailed experience...

  17. Calibration of aerosol radiometers. Special aerosol sources

    International Nuclear Information System (INIS)

    Belkina, S.K.; Zalmanzon, Yu.E.; Kuznetsov, Yu.V.; Fertman, D.E.

    1988-01-01

    Problems of calibration of artificial aerosol radiometry and information-measurement systems of radiometer radiation control, in particular, are considered. Special aerosol source is suggested, which permits to perform certification and testing of aerosol channels of the systems in situ without the dismantling

  18. Tanks for liquids: calibration and errors assessment

    International Nuclear Information System (INIS)

    Espejo, J.M.; Gutierrez Fernandez, J.; Ortiz, J.

    1980-01-01

    After a brief reference to some of the problems raised by tanks calibration, two methods, theoretical and experimental are presented, so as to achieve it taking into account measurement errors. The method is applied to the transfer of liquid from one tank to another. Further, a practical example is developed. (author)

  19. POLCAL - POLARIMETRIC RADAR CALIBRATION

    Science.gov (United States)

    Vanzyl, J.

    1994-01-01

    Calibration of polarimetric radar systems is a field of research in which great progress has been made over the last few years. POLCAL (Polarimetric Radar Calibration) is a software tool intended to assist in the calibration of Synthetic Aperture Radar (SAR) systems. In particular, POLCAL calibrates Stokes matrix format data produced as the standard product by the NASA/Jet Propulsion Laboratory (JPL) airborne imaging synthetic aperture radar (AIRSAR). POLCAL was designed to be used in conjunction with data collected by the NASA/JPL AIRSAR system. AIRSAR is a multifrequency (6 cm, 24 cm, and 68 cm wavelength), fully polarimetric SAR system which produces 12 x 12 km imagery at 10 m resolution. AIRSTAR was designed as a testbed for NASA's Spaceborne Imaging Radar program. While the images produced after 1991 are thought to be calibrated (phase calibrated, cross-talk removed, channel imbalance removed, and absolutely calibrated), POLCAL can and should still be used to check the accuracy of the calibration and to correct it if necessary. Version 4.0 of POLCAL is an upgrade of POLCAL version 2.0 released to AIRSAR investigators in June, 1990. New options in version 4.0 include automatic absolute calibration of 89/90 data, distributed target analysis, calibration of nearby scenes with calibration parameters from a scene with corner reflectors, altitude or roll angle corrections, and calibration of errors introduced by known topography. Many sources of error can lead to false conclusions about the nature of scatterers on the surface. Errors in the phase relationship between polarization channels result in incorrect synthesis of polarization states. Cross-talk, caused by imperfections in the radar antenna itself, can also lead to error. POLCAL reduces cross-talk and corrects phase calibration without the use of ground calibration equipment. Removing the antenna patterns during SAR processing also forms a very important part of the calibration of SAR data. Errors in the

  20. Vibration transducer calibration techniques

    Science.gov (United States)

    Brinkley, D. J.

    1980-09-01

    Techniques for the calibration of vibration transducers used in the Aeronautical Quality Assurance Directorate of the British Ministry of Defence are presented. Following a review of the types of measurements necessary in the calibration of vibration transducers, the performance requirements of vibration transducers, which can be used to measure acceleration, velocity or vibration amplitude, are discussed, with particular attention given to the piezoelectric accelerometer. Techniques for the accurate measurement of sinusoidal vibration amplitude in reference-grade transducers are then considered, including the use of a position sensitive photocell and the use of a Michelson laser interferometer. Means of comparing the output of working-grade accelerometers with that of previously calibrated reference-grade devices are then outlined, with attention given to a method employing a capacitance bridge technique and a method to be used at temperatures between -50 and 200 C. Automatic calibration procedures developed to speed up the calibration process are outlined, and future possible extensions of system software are indicated.

  1. Robust multi-objective calibration strategies – possibilities for improving flood forecasting

    Directory of Open Access Journals (Sweden)

    G. H. Schmitz

    2012-10-01

    Full Text Available Process-oriented rainfall-runoff models are designed to approximate the complex hydrologic processes within a specific catchment and in particular to simulate the discharge at the catchment outlet. Most of these models exhibit a high degree of complexity and require the determination of various parameters by calibration. Recently, automatic calibration methods became popular in order to identify parameter vectors with high corresponding model performance. The model performance is often assessed by a purpose-oriented objective function. Practical experience suggests that in many situations one single objective function cannot adequately describe the model's ability to represent any aspect of the catchment's behaviour. This is regardless of whether the objective is aggregated of several criteria that measure different (possibly opposite aspects of the system behaviour. One strategy to circumvent this problem is to define multiple objective functions and to apply a multi-objective optimisation algorithm to identify the set of Pareto optimal or non-dominated solutions. Nonetheless, there is a major disadvantage of automatic calibration procedures that understand the problem of model calibration just as the solution of an optimisation problem: due to the complex-shaped response surface, the estimated solution of the optimisation problem can result in different near-optimum parameter vectors that can lead to a very different performance on the validation data. Bárdossy and Singh (2008 studied this problem for single-objective calibration problems using the example of hydrological models and proposed a geometrical sampling approach called Robust Parameter Estimation (ROPE. This approach applies the concept of data depth in order to overcome the shortcomings of automatic calibration procedures and find a set of robust parameter vectors. Recent studies confirmed the effectivity of this method. However, all ROPE approaches published so far just identify

  2. Calibration of the solar UV radiometers in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Leszczynski, K.; Jokela, K.; Visuri, R.; Ylianttila, L. [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland). Non-Ionizing Radiation Lab.

    1996-12-31

    In this report, the main emphasis is given to (1) the problems associated with the basic calibration of the spectroradiometer and (2) the year-to-year variability of the calibrations of the solar UV network radiometers. Also, the results from intercomparisons of the Brewer and OL 742 spectroradiometers are included

  3. Information management for maintenance of instrument calibration data

    International Nuclear Information System (INIS)

    Tam, Y.

    1995-01-01

    This paper discusses the rationale for developing a calibration information system at Ontario Hydro Pickering Nuclear Division (PND), including the approach to calibration information problems, the identification of existing processes, discovery of alternatives, selection of the best alternative and project development. (author)

  4. Calibration of the solar UV radiometers in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Leszczynski, K; Jokela, K; Visuri, R; Ylianttila, L [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland). Non-Ionizing Radiation Lab.

    1997-12-31

    In this report, the main emphasis is given to (1) the problems associated with the basic calibration of the spectroradiometer and (2) the year-to-year variability of the calibrations of the solar UV network radiometers. Also, the results from intercomparisons of the Brewer and OL 742 spectroradiometers are included

  5. Ibis ground calibration

    International Nuclear Information System (INIS)

    Bird, A.J.; Barlow, E.J.; Tikkanen, T.; Bazzano, A.; Del Santo, M.; Ubertini, P.; Blondel, C.; Laurent, P.; Lebrun, F.; Di Cocco, G.; Malaguti, E.; Gabriele, M.; La Rosa, G.; Segreto, A.; Quadrini, E.; Volkmer, R.

    2003-01-01

    We present an overview of results obtained from IBIS ground calibrations. The spectral and spatial characteristics of the detector planes and surrounding passive materials have been determined through a series of calibration campaigns. Measurements of pixel gain, energy resolution, detection uniformity, efficiency and imaging capability are presented. The key results obtained from the ground calibration have been: - optimization of the instrument tunable parameters, - determination of energy linearity for all detection modes, - determination of energy resolution as a function of energy through the range 20 keV - 3 MeV, - demonstration of imaging capability in each mode, - measurement of intrinsic detector non-uniformity and understanding of the effects of passive materials surrounding the detector plane, and - discovery (and closure) of various leakage paths through the passive shielding system

  6. Individual dosimetry and calibration

    International Nuclear Information System (INIS)

    Hoefert, M.; Nielsen, M.

    1996-01-01

    In 1995 both the Individual Dosimetry and Calibration Sections worked under the condition of a status quo and concentrated fully on the routine part of their work. Nevertheless, the machine for printing the bar code which will be glued onto the film holder and hence identify the people when entering into high radiation areas was put into operation and most of the holders were equipped with the new identification. As far as the Calibration Section is concerned the project of the new source control system that is realized by the Technical Support Section was somewhat accelerated

  7. Calibrating Legal Judgments

    Directory of Open Access Journals (Sweden)

    Frederick Schauer

    2017-09-01

    Full Text Available Objective to study the notion and essence of legal judgments calibration the possibilities of using it in the lawenforcement activity to explore the expenses and advantages of using it. Methods dialectic approach to the cognition of social phenomena which enables to analyze them in historical development and functioning in the context of the integrity of objective and subjective factors it determined the choice of the following research methods formallegal comparative legal sociological methods of cognitive psychology and philosophy. Results In ordinary life people who assess other peoplersaquos judgments typically take into account the other judgments of those they are assessing in order to calibrate the judgment presently being assessed. The restaurant and hotel rating website TripAdvisor is exemplary because it facilitates calibration by providing access to a raterrsaquos previous ratings. Such information allows a user to see whether a particular rating comes from a rater who is enthusiastic about every place she patronizes or instead from someone who is incessantly hard to please. And even when less systematized as in assessing a letter of recommendation or college transcript calibration by recourse to the decisional history of those whose judgments are being assessed is ubiquitous. Yet despite the ubiquity and utility of such calibration the legal system seems perversely to reject it. Appellate courts do not openly adjust their standard of review based on the previous judgments of the judge whose decision they are reviewing nor do judges in reviewing legislative or administrative decisions magistrates in evaluating search warrant representations or jurors in assessing witness perception. In most legal domains calibration by reference to the prior decisions of the reviewee is invisible either because it does not exist or because reviewing bodies are unwilling to admit using what they in fact know and employ. Scientific novelty for the first

  8. Calibration of scanning Lidar

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Courtney, Michael

    This report describes the tests carried out on a scanning lidar at the DTU Test Station for large wind turbines, Høvsøre. The tests were divided in two parts. In the first part, the purpose was to obtain wind speed calibrations at two heights against two cup anemometers mounted on a mast. Additio......This report describes the tests carried out on a scanning lidar at the DTU Test Station for large wind turbines, Høvsøre. The tests were divided in two parts. In the first part, the purpose was to obtain wind speed calibrations at two heights against two cup anemometers mounted on a mast...

  9. State of the art: two-phase flow calibration techniques

    International Nuclear Information System (INIS)

    Stanley, M.L.

    1977-01-01

    The nuclear community faces a particularly difficult problem relating to the calibration of instrumentation in a two-phase flow steam/water environment. The rationale of the approach to water reactor safety questions in the United States demands that accurate measurements of mass flows in a decompressing two-phase flow be made. An accurate measurement dictates an accurate calibration. This paper addresses three questions relating to the state of the art in two-phase calibration: (1) What do we mean by calibration. (2) What is done now. (3) What should be done

  10. Proton beam monitor chamber calibration

    International Nuclear Information System (INIS)

    Gomà, C; Meer, D; Safai, S; Lorentini, S

    2014-01-01

    The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic proton beam. For the latter, this paper also compares two independent dosimetry techniques to calibrate the beam monitor chambers: absolute dosimetry (of the number of protons exiting the nozzle) with a Faraday cup and reference dosimetry (i.e. determination of the absorbed dose to water under IAEA TRS-398 reference conditions) with an ionization chamber. To compare the two techniques, Monte Carlo simulations were performed to convert dose-to-water to proton fluence. A good agreement was found between the Faraday cup technique and the reference dosimetry with a plane-parallel ionization chamber. The differences—of the order of 3%—were found to be within the uncertainty of the comparison. For cylindrical ionization chambers, however, the agreement was only possible when positioning the effective point of measurement of the chamber at the reference measurement depth—i.e. not complying with IAEA TRS-398 recommendations. In conclusion, for cylindrical ionization chambers, IAEA TRS-398 reference conditions for monoenergetic proton beams led to a systematic error in the determination of the absorbed dose to water, especially relevant for low-energy proton beams. To overcome this problem, the effective point of measurement of cylindrical ionization chambers should be taken into account when positioning the reference point of the chamber. Within the current IAEA TRS-398 recommendations, it seems advisable to use plane-parallel ionization chambers—rather than cylindrical chambers—for the reference dosimetry of pseudo-monoenergetic proton beams. (paper)

  11. Absolute calibration of SARAL/AltiKa in Kavaratti during its initial calibration-validation phase

    Digital Repository Service at National Institute of Oceanography (India)

    Babu, K.N.; Shukla, A.K.; Suchandra, A.B.; ArunKumar, S.V.V.; Bonnefond, P.; Testut, L.; Mehra, P.; Laurain, O.

    globally distributed region will offer assessment of the altimetry system, and allow us to check in specific conditions leading to different estimation of absolute bias of the instrument (Shum et al. 2003). In collaboration with National Institute... of Oceanography (NIO), Goa, Space Applica- tions Centre–Indian Space Research Organisation (SAC-ISRO) established a calibration- verification site in Kavaratti. This site offers a number of advantages as a calibration site for altimeters. Having very small land...

  12. Specificity of problem-solving skills training in mothers of children newly diagnosed with cancer: results of a multisite randomized clinical trial.

    Science.gov (United States)

    Sahler, Olle Jane Z; Dolgin, Michael J; Phipps, Sean; Fairclough, Diane L; Askins, Martha A; Katz, Ernest R; Noll, Robert B; Butler, Robert W

    2013-04-01

    Diagnosis of cancer in a child can be extremely stressful for parents. Bright IDEAS, a problem-solving skills training (PSST) intervention, has been shown to decrease negative affectivity (anxiety, depression, post-traumatic stress symptoms) in mothers of newly diagnosed patients. This study was designed to determine the specificity of PSST by examining its direct and indirect (eg, social support) effects compared with a nondirective support (NDS) intervention. This randomized clinical trial included 309 English- or Spanish-speaking mothers of children diagnosed 2 to 16 weeks before recruitment. Participants completed assessments prerandomization (T1), immediately postintervention (T2), and at 3-month follow-up (T3). Both PSST and NDS consisted of eight weekly 1-hour individual sessions. Outcomes included measures of problem-solving skill and negative affectivity. There were no significant between-group differences at baseline (T1). Except for level of problem-solving skill, which was directly taught in the PSST arm, outcome measures improved equally in both groups immediately postintervention (T2). However, at the 3-month follow-up (T3), mothers in the PSST group continued to show significant improvements in mood, anxiety, and post-traumatic stress; mothers in the NDS group showed no further significant gains. PSST is an effective and specific intervention whose beneficial effects continue to grow after the intervention ends. In contrast, NDS is an effective intervention while it is being administered, but its benefits plateau when active support is removed. Therefore, teaching coping skills at diagnosis has the potential to facilitate family resilience over the entire course of treatment.

  13. ECAL Energy Flow Calibration

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    My talk will be covering my work as a whole over the course of the semester. The focus will be on using energy flow calibration in ECAL to check the precision of the corrections made by the light monitoring system used to account for transparency loss within ECAL crystals due to radiation damage over time.

  14. Calibration with Absolute Shrinkage

    DEFF Research Database (Denmark)

    Øjelund, Henrik; Madsen, Henrik; Thyregod, Poul

    2001-01-01

    In this paper, penalized regression using the L-1 norm on the estimated parameters is proposed for chemometric je calibration. The algorithm is of the lasso type, introduced by Tibshirani in 1996 as a linear regression method with bound on the absolute length of the parameters, but a modification...

  15. Calibration bench of flowmeters

    International Nuclear Information System (INIS)

    Bremond, J.; Da Costa, D.; Calvet, A.; Vieuxmaire, C.

    1966-01-01

    This equipment is devoted to the comparison of signals from two turbines installed in the Cabri experimental loop. The signal is compared to the standard turbine. The characteristics and the performance of the calibration bench are presented. (A.L.B.)

  16. Calibration of farmer dosemeters

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Anwar, K.; Arshed, W.; Mubarak, M.A.; Orfi, S.D.

    1984-08-01

    The Farmer Dosemeters of Atomic Energy Medical Centre (AEMC) Jamshoro were calibrated in the Secondary Standard Dosimetry Laboratory (SSDL) at PINSTECH, using the NPL Secondary Standard Therapy level X-ray exposure meter. The results are presented in this report. (authors)

  17. NVLAP calibration laboratory program

    Energy Technology Data Exchange (ETDEWEB)

    Cigler, J.L.

    1993-12-31

    This paper presents an overview of the progress up to April 1993 in the development of the Calibration Laboratories Accreditation Program within the framework of the National Voluntary Laboratory Accreditation Program (NVLAP) at the National Institute of Standards and Technology (NIST).

  18. NVLAP calibration laboratory program

    International Nuclear Information System (INIS)

    Cigler, J.L.

    1993-01-01

    This paper presents an overview of the progress up to April 1993 in the development of the Calibration Laboratories Accreditation Program within the framework of the National Voluntary Laboratory Accreditation Program (NVLAP) at the National Institute of Standards and Technology (NIST)

  19. Gamma ray calibration system

    International Nuclear Information System (INIS)

    Rosauer, P.J.; Flaherty, J.J.

    1981-01-01

    This invention is in the field of gamma ray inspection devices for tubular products and the like employing an improved calibrating block which prevents the sensing system from being overloaded when no tubular product is present, and also provides the operator with a means for visually detecting the presence of wall thicknesses which are less than a required minimum. (author)

  20. Calibration and quality control for personnel dose meter

    International Nuclear Information System (INIS)

    Wu Rongtao; Zhang Dianqin

    1999-01-01

    Calibration and quality control are the important aspects to assure thermoluminescence dose measurement compliance with the technical standards. The author discussed some problems to implement technical standards and regulations

  1. Calibration of a detector for pulsed neutron sources

    International Nuclear Information System (INIS)

    Veeser, L.R.; Hemmendinger, A.; Shunk, E.R.

    1978-02-01

    A plastic scintillator detector for measuring the strength of a pulsed neutron source is described and the problems of calibration and discrimination against x-ray background for both pulsed and steady-state detectors are discussed

  2. Calibration of groundwater vulnerability mapping using the generalized reduced gradient method.

    Science.gov (United States)

    Elçi, Alper

    2017-12-01

    Groundwater vulnerability assessment studies are essential in water resources management. Overlay-and-index methods such as DRASTIC are widely used for mapping of groundwater vulnerability, however, these methods mainly suffer from a subjective selection of model parameters. The objective of this study is to introduce a calibration procedure that results in a more accurate assessment of groundwater vulnerability. The improvement of the assessment is formulated as a parameter optimization problem using an objective function that is based on the correlation between actual groundwater contamination and vulnerability index values. The non-linear optimization problem is solved with the generalized-reduced-gradient (GRG) method, which is numerical algorithm based optimization method. To demonstrate the applicability of the procedure, a vulnerability map for the Tahtali stream basin is calibrated using nitrate concentration data. The calibration procedure is easy to implement and aims the maximization of correlation between observed pollutant concentrations and groundwater vulnerability index values. The influence of each vulnerability parameter in the calculation of the vulnerability index is assessed by performing a single-parameter sensitivity analysis. Results of the sensitivity analysis show that all factors are effective on the final vulnerability index. Calibration of the vulnerability map improves the correlation between index values and measured nitrate concentrations by 19%. The regression coefficient increases from 0.280 to 0.485. It is evident that the spatial distribution and the proportions of vulnerability class areas are significantly altered with the calibration process. Although the applicability of the calibration method is demonstrated on the DRASTIC model, the applicability of the approach is not specific to a certain model and can also be easily applied to other overlay-and-index methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. CVM-X: Calibrating contingent values with experimental auction markets

    International Nuclear Information System (INIS)

    Fox, J.A.; Shogren, J.F.; Hayes, D.J.; Kliebenstein, J.B.

    1998-01-01

    We design and implement a method, CVM-X, to calibrate hypothetical survey values using experimental auction markets. We test the procedure using consumer willingness-to-pay for irradiated/nonirradiated meat. Our results show that calibration factors for those who favor the irradiation process (0.67-0.69) are less severe than for those with an initial dislike of the process (0.55-0.59), suggesting that calibration may be commodity specific

  4. PLEIADES ABSOLUTE CALIBRATION : INFLIGHT CALIBRATION SITES AND METHODOLOGY

    Directory of Open Access Journals (Sweden)

    S. Lachérade

    2012-07-01

    Full Text Available In-flight calibration of space sensors once in orbit is a decisive step to be able to fulfil the mission objectives. This article presents the methods of the in-flight absolute calibration processed during the commissioning phase. Four In-flight calibration methods are used: absolute calibration, cross-calibration with reference sensors such as PARASOL or MERIS, multi-temporal monitoring and inter-bands calibration. These algorithms are based on acquisitions over natural targets such as African deserts, Antarctic sites, La Crau (Automatic calibration station and Oceans (Calibration over molecular scattering or also new extra-terrestrial sites such as the Moon and selected stars. After an overview of the instrument and a description of the calibration sites, it is pointed out how each method is able to address one or several aspects of the calibration. We focus on how these methods complete each other in their operational use, and how they help building a coherent set of information that addresses all aspects of in-orbit calibration. Finally, we present the perspectives that the high level of agility of PLEIADES offers for the improvement of its calibration and a better characterization of the calibration sites.

  5. Mercury CEM Calibration

    Energy Technology Data Exchange (ETDEWEB)

    John F. Schabron; Joseph F. Rovani; Susan S. Sorini

    2007-03-31

    The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005, requires that calibration of mercury continuous emissions monitors (CEMs) be performed with NIST-traceable standards. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor generators. The traceability protocol will be written by EPA. Traceability will be based on the actual analysis of the output of each calibration unit at several concentration levels ranging from about 2-40 ug/m{sup 3}, and this analysis will be directly traceable to analyses by NIST using isotope dilution inductively coupled plasma/mass spectrometry (ID ICP/MS) through a chain of analyses linking the calibration unit in the power plant to the NIST ID ICP/MS. Prior to this project, NIST did not provide a recommended mercury vapor pressure equation or list mercury vapor pressure in its vapor pressure database. The NIST Physical and Chemical Properties Division in Boulder, Colorado was subcontracted under this project to study the issue in detail and to recommend a mercury vapor pressure equation that the vendors of mercury vapor pressure calibration units can use to calculate the elemental mercury vapor concentration in an equilibrium chamber at a particular temperature. As part of this study, a preliminary evaluation of calibration units from five vendors was made. The work was performed by NIST in Gaithersburg, MD and Joe Rovani from WRI who traveled to NIST as a Visiting Scientist.

  6. Essay on Option Pricing, Hedging and Calibration

    DEFF Research Database (Denmark)

    da Silva Ribeiro, André Manuel

    Quantitative finance is concerned about applying mathematics to financial markets.This thesis is a collection of essays that study different problems in this field: How efficient are option price approximations to calibrate a stochastic volatilitymodel? (Chapter 2) How different is the discretely...... of dynamics? (Chapter 5) How can we formulate a simple free-arbitrage model to price correlationswaps? (Chapter 6) A summary of the work presented in this thesis: Approximation Behooves Calibration In this paper we show that calibration based on an expansion approximation for option prices in the Heston...... stochastic volatility model gives stable, accurate, and fast results for S&P500-index option data over the period 2005 to 2009. Discretely Sampled Variance Options: A Stochastic Approximation Approach In this paper, we expand Drimus and Farkas (2012) framework to price variance options on discretely sampled...

  7. A simplified method of power calibration

    International Nuclear Information System (INIS)

    Jones, M.; Elliott, A.

    1974-01-01

    The Nuclear Reactor Facility, University of Missouri Rolla, has developed a unique method of power calibration for pool type reactors. Since water is incompressible it can be assumed that a rise in the water level of the pool while operating at power can be attributed to the heat input from the reactor core. Water level changes of a small magnitude are easily detectable. This method has proven to be less costly, less time consuming, and more reproducible than the conventional gold foil calibration, and has proven to be more accurate than a heat balance because several problems with heat flow through the walls and to the atmosphere are automatically compensated for with this method. The accuracy of this means of calibration depends upon the accuracy of the measurement of the water level and can normally be expected to be two to four percent. (author)

  8. A simplified method of power calibration

    Energy Technology Data Exchange (ETDEWEB)

    Jones, M; Elliott, A [University of Missouri-Rolla (United States)

    1974-07-01

    The Nuclear Reactor Facility, University of Missouri Rolla, has developed a unique method of power calibration for pool type reactors. Since water is incompressible it can be assumed that a rise in the water level of the pool while operating at power can be attributed to the heat input from the reactor core. Water level changes of a small magnitude are easily detectable. This method has proven to be less costly, less time consuming, and more reproducible than the conventional gold foil calibration, and has proven to be more accurate than a heat balance because several problems with heat flow through the walls and to the atmosphere are automatically compensated for with this method. The accuracy of this means of calibration depends upon the accuracy of the measurement of the water level and can normally be expected to be two to four percent. (author)

  9. Series: The research agenda for general practice/family medicine and primary health care in Europe. Part 4. Results: specific problem solving skills.

    Science.gov (United States)

    Hummers-Pradier, Eva; Beyer, Martin; Chevallier, Patrick; Eilat-Tsanani, Sophia; Lionis, Christos; Peremans, Lieve; Petek, Davorina; Rurik, Imre; Soler, Jean Karl; Stoffers, Henri Ejh; Topsever, Pinar; Ungan, Mehmet; van Royen, Paul

    2010-09-01

    The 'Research Agenda for General Practice/Family Medicine and Primary Health Care in Europe' summarizes the evidence relating to the core competencies and characteristics of the Wonca Europe definition of GP/FM, and its implications for general practitioners/family doctors, researchers and policy makers. The European Journal of General Practice publishes a series of articles based on this document. The previous articles presented background, objectives, and methodology, as well results on 'primary care management' and 'community orientation' and the person-related core competencies of GP/FM. This article reflects on the general practitioner's 'specific problem solving skills'. These include decision making on diagnosis and therapy of specific diseases, accounting for the properties of primary care, but also research questions related to quality management and resource use, shared decision making, or professional education and development. Clinical research covers most specific diseases, but often lacks pragmatism and primary care relevance. Quality management is a stronghold of GP/FM research. Educational interventions can be effective when well designed for a specific setting and situation. However, their message that 'usual care' by general practitioners is insufficient may be problematic. GP and their patients need more research into diagnostic reasoning with a step-wise approach to increase predictive values in a setting characterized by uncertainty and low prevalence of specific diseases. Pragmatic comparative effectiveness studies of new and established drugs or non-pharmaceutical therapy are needed. Multi-morbidity and complexity should be addressed. Studies on therapy, communication strategies and educational interventions should consider impact on health and sustainability of effects.

  10. Field calibration of cup anemometers

    DEFF Research Database (Denmark)

    Schmidt Paulsen, Uwe; Mortensen, Niels Gylling; Hansen, Jens Carsten

    2007-01-01

    A field calibration method and results are described along with the experience gained with the method. The cup anemometers to be calibrated are mounted in a row on a 10-m high rig and calibrated in the free wind against a reference cup anemometer. The method has been reported [1] to improve...... the statistical bias on the data relative to calibrations carried out in a wind tunnel. The methodology is sufficiently accurate for calibration of cup anemometers used for wind resource assessments and provides a simple, reliable and cost-effective solution to cup anemometer calibration, especially suited...

  11. At-risk and problem gambling among Finnish youth: The examination of risky alcohol consumption, tobacco smoking, mental health and loneliness as gender-specific correlates

    Directory of Open Access Journals (Sweden)

    Edgren Robert

    2016-02-01

    Full Text Available AIMS - The aims were to compare past-year at-risk and problem gambling (ARPG and other at-risk behaviours (computer gaming, risky alcohol consumption, tobacco smoking by age and gender, and to explore how ARPG is associated with risky alcohol consumption, tobacco smoking, poor mental health and loneliness in males and females. DESIGN - Data from respondents aged 15-28 (n = 822 were derived from a cross-sectional random sample of population-based data (n = 4484. The data were collected in 2011-2012 by telephone interviews. The Problem Gambling Severity Index (PGSI, score≥2 was used to evaluate ARPG. Prevalence rates for risk behaviours were compared for within gender-specific age groups. Regression models were gender-specific. RESULTS - The proportion of at-risk and problem gamblers was higher among males than females in all age groups except among 18-21-year-olds, while frequent computer gaming was higher among males in all age groups. The odds ratio (95% CI of being a male ARPGer was 2.57 (1.40-4.74 for risky alcohol consumption; 1.95 (1.07-3.56 for tobacco smoking; 2.63 (0.96-7.26 for poor mental health; and 4.41 (1.20-16.23 for feeling lonely. Likewise, the odds ratio (95% CI of being a female ARPGer was 1.19 (0.45-3.12 for risky alcohol consumption; 4.01 (1.43-11.24 for tobacco smoking; 0.99 (0.18-5.39 for poor mental health; and 6.46 (1.42-29.34 for feeling lonely. All 95% CIs of ARPG correlates overlapped among males and females. CONCLUSIONS - Overall, past-year at-risk and problem gambling and computer gaming seem to be more common among males than females; however, for risky alcohol consumption similar gender differences were evident only for the older half of the sample. No clear gender differences were seen in correlates associated with ARPG.

  12. Online examiner calibration across specialties.

    Science.gov (United States)

    Sturman, Nancy; Wong, Wai Yee; Turner, Jane; Allan, Chris

    2017-09-26

    Integrating undergraduate medical curricula horizontally across clinical medical specialties may be a more patient-centred and learner-centred approach than rotating students through specialty-specific teaching and assessment, but requires some interspecialty calibration of examiner judgements. Our aim was to evaluate the acceptability and feasibility of an online pilot of interdisciplinary examiner calibration. Fair clinical assessment is important to both medical students and clinical teachers METHODS: Clinical teachers were invited to rate video-recorded student objective structured clinical examination (OSCE) performances and join subsequent online discussions using the university's learning management system. Post-project survey free-text and Likert-scale participant responses were analysed to evaluate the acceptability of the pilot and to identify recommendations for improvement. Although 68 clinicians were recruited to participate, and there were 1599 hits on recordings and discussion threads, only 25 clinical teachers rated at least one student performance, and 18 posted at least one comment. Participants, including rural doctors, appeared to value the opportunity for interdisciplinary rating calibration and discussion. Although the asynchronous online format had advantages, especially for rural doctors, participants reported considerable IT challenges. Our findings suggest that fair clinical assessment is important to both medical students and clinical teachers. Interspecialty discussions about assessment may have the potential to enrich intraspecialty perspectives, enhance interspecialty engagement and collaboration, and improve the quality of clinical teacher assessment. Better alignment of university and hospital systems, a face to face component and other modifications may have enhanced clinician engagement with this project. Findings suggest that specialty assessment cultures and content expertise may not be barriers to pursuing more integrated

  13. Individual dosimetry and calibration

    International Nuclear Information System (INIS)

    Otto, T.

    1997-01-01

    In 1996, the Dosimetry and Calibration Section was, as in previous years, mainly engaged in routine tasks: the distribution of over 6000 dosimeters (with a total of more than 10,000 films) every two months and the calibration of about 900 fixed and mobile instruments used in the radiation survey sections of RP group. These tasks were, thanks to an experienced team, well mastered. Special efforts had to be made in a number of areas to modernize the service or to keep it in line with new prescriptions. The Individual Dosimetry Service had to assure that CERN's contracting firms comply with the prescriptions in the Radiation Safety Manual (1996) that had been inspired by the Swiss Ordinance of 1994: Companies must file for authorizations with the Swiss Federal Office for Public Health requiring that in every company an 'Expert in Radiation Protection' be nominated and subsequently trained. CERN's Individual Dosimetry Service is accredited by the Swiss Federal Authorities and works closely together with other, similar services on a rigorous quality assurance programme. Within this framework, CERN was mandated to organize this year the annual Swiss 'Intercomparison of Dosimeters'. All ten accredited dosimetry services - among others those of the Paul Scherrer Institute (PSI) in Villigen and of the four Swiss nuclear power stations - sent dosimeters to CERN, where they were irradiated in CERN's calibration facility with precise photon doses. After return to their origin they were processed and evaluated. The results were communicated to CERN and were compared with the originally given doses. A report on the results was subsequently prepared and submitted to the Swiss 'Group of Experts on Personal Dosimetry'. Reference monitors for photon and neutron radiation were brought to standard laboratories to assure the traceability of CERN's calibration service to the fundamental quantities. For photon radiation, a set of ionization chambers was calibrated in the reference field

  14. MAVEN SEP Calibrated Data Bundle

    Data.gov (United States)

    National Aeronautics and Space Administration — The maven.sep.calibrated Level 2 Science Data Bundle contains fully calibrated SEP data, as well as the raw count data from which they are derived, and ancillary...

  15. Travelling gradient thermocouple calibration

    International Nuclear Information System (INIS)

    Broomfield, G.H.

    1975-01-01

    A short discussion of the origins of the thermocouple EMF is used to re-introduce the idea that the Peltier and Thompson effects are indistinguishable from one another. Thermocouples may be viewed as devices which generate an EMF at junctions or as integrators of EMF's developed in thermal gradients. The thermal gradient view is considered the more appropriate, because of its better accord with theory and behaviour, the correct approach to calibration, and investigation of service effects is immediately obvious. Inhomogeneities arise in thermocouples during manufacture and in service. The results of travelling gradient measurements are used to show that such effects are revealed with a resolution which depends on the length of the gradient although they may be masked during simple immersion calibration. Proposed tests on thermocouples irradiated in a nuclear reactor are discussed

  16. Calibration Methods for Reliability-Based Design Codes

    DEFF Research Database (Denmark)

    Gayton, N.; Mohamed, A.; Sørensen, John Dalsgaard

    2004-01-01

    The calibration methods are applied to define the optimal code format according to some target safety levels. The calibration procedure can be seen as a specific optimization process where the control variables are the partial factors of the code. Different methods are available in the literature...

  17. Mesoscale hybrid calibration artifact

    Science.gov (United States)

    Tran, Hy D.; Claudet, Andre A.; Oliver, Andrew D.

    2010-09-07

    A mesoscale calibration artifact, also called a hybrid artifact, suitable for hybrid dimensional measurement and the method for make the artifact. The hybrid artifact has structural characteristics that make it suitable for dimensional measurement in both vision-based systems and touch-probe-based systems. The hybrid artifact employs the intersection of bulk-micromachined planes to fabricate edges that are sharp to the nanometer level and intersecting planes with crystal-lattice-defined angles.

  18. Calibration of hydrometers

    Science.gov (United States)

    Lorefice, Salvatore; Malengo, Andrea

    2006-10-01

    After a brief description of the different methods employed in periodic calibration of hydrometers used in most cases to measure the density of liquids in the range between 500 kg m-3 and 2000 kg m-3, particular emphasis is given to the multipoint procedure based on hydrostatic weighing, known as well as Cuckow's method. The features of the calibration apparatus and the procedure used at the INRiM (formerly IMGC-CNR) density laboratory have been considered to assess all relevant contributions involved in the calibration of different kinds of hydrometers. The uncertainty is strongly dependent on the kind of hydrometer; in particular, the results highlight the importance of the density of the reference buoyant liquid, the temperature of calibration and the skill of operator in the reading of the scale in the whole assessment of the uncertainty. It is also interesting to realize that for high-resolution hydrometers (division of 0.1 kg m-3), the uncertainty contribution of the density of the reference liquid is the main source of the total uncertainty, but its importance falls under about 50% for hydrometers with a division of 0.5 kg m-3 and becomes somewhat negligible for hydrometers with a division of 1 kg m-3, for which the reading uncertainty is the predominant part of the total uncertainty. At present the best INRiM result is obtained with commercially available hydrometers having a scale division of 0.1 kg m-3, for which the relative uncertainty is about 12 × 10-6.

  19. Observation models in radiocarbon calibration

    International Nuclear Information System (INIS)

    Jones, M.D.; Nicholls, G.K.

    2001-01-01

    The observation model underlying any calibration process dictates the precise mathematical details of the calibration calculations. Accordingly it is important that an appropriate observation model is used. Here this is illustrated with reference to the use of reservoir offsets where the standard calibration approach is based on a different model to that which the practitioners clearly believe is being applied. This sort of error can give rise to significantly erroneous calibration results. (author). 12 refs., 1 fig

  20. Calibrated Properties Model

    International Nuclear Information System (INIS)

    Ghezzehej, T.

    2004-01-01

    The purpose of this model report is to document the calibrated properties model that provides calibrated property sets for unsaturated zone (UZ) flow and transport process models (UZ models). The calibration of the property sets is performed through inverse modeling. This work followed, and was planned in, ''Technical Work Plan (TWP) for: Unsaturated Zone Flow Analysis and Model Report Integration'' (BSC 2004 [DIRS 169654], Sections 1.2.6 and 2.1.1.6). Direct inputs to this model report were derived from the following upstream analysis and model reports: ''Analysis of Hydrologic Properties Data'' (BSC 2004 [DIRS 170038]); ''Development of Numerical Grids for UZ Flow and Transport Modeling'' (BSC 2004 [DIRS 169855]); ''Simulation of Net Infiltration for Present-Day and Potential Future Climates'' (BSC 2004 [DIRS 170007]); ''Geologic Framework Model'' (GFM2000) (BSC 2004 [DIRS 170029]). Additionally, this model report incorporates errata of the previous version and closure of the Key Technical Issue agreement TSPAI 3.26 (Section 6.2.2 and Appendix B), and it is revised for improved transparency

  1. Parameterizations for reducing camera reprojection error for robot-world hand-eye calibration

    Science.gov (United States)

    Accurate robot-world, hand-eye calibration is crucial to automation tasks. In this paper, we discuss the robot-world, hand-eye calibration problem which has been modeled as the linear relationship AX equals ZB, where X and Z are the unknown calibration matrices composed of rotation and translation ...

  2. Calibration of laboratory equipment and its intermediate verification

    International Nuclear Information System (INIS)

    Remedi, Jorge O.

    2011-01-01

    When a laboratory wants to prove that he has technical competence to carry out tests or calibrations must demonstrate that it has complied with certain requirements that establish , among others, the mandatory : calibrate or verify equipment before putting it into service in order to ensure that it meets to the specifications of laboratory equipment to keep records evidencing the checks that equipment complies with the specification ; perform intermediate checks for maintain confidence in the calibration status of the equipment , ensure that the operation is checked and calibration status of equipment when the equipment goes outside the direct control of the laboratory , before be returned to service, establish a program and procedure for the calibration of equipment; show how determined the calibration periods of their equipment as well as evidence that intermediate checks are suitable for the calibration periods. However, some confusion is observed as to the meaning of the terms 'calibration' and 'verification' of a computer. This paper analyzes applicable documentation and suggests that the differences are generated in part by translations and by characterization concepts upon its usage, that is, if it is legal metrology or assessment conformity. Therefore, this study aims to characterize both concepts , fundamentals to zoom distinguish , outline appropriate strategies for calibration and verification activities to ensure the compliance with regulatory requirements [es

  3. A Study on Relative Radiometric Calibration without Calibration Field for YG-25

    Directory of Open Access Journals (Sweden)

    ZHANG Guo

    2017-08-01

    Full Text Available YG-25 is the first agility optical remote sensing satellite of China to acquire the sub-meter imagery of the earth. The side slither calibration technique is an on-orbit maneuver that has been used to flat-field image data acquired over the uniform calibration field. However, imaging to the single uniform calibration field cannot afford to calibrate the full dynamic response range of the sensor and reduces the efficiency. The paper proposes a new relative radiometric calibration method that a 90-degree yaw maneuver is performed over any non-uniform features of the Earth for YG-25. Meanwhile, we use an enhanced side slither image horizontal correction method based on line segment detector(LSDalgorithm to solve the side slither image over-shifted problem.The shifted results are compared with other horizontal correction method. The histogram match algorithm is used to calculate the relative gains of all detectors. The correctness and validity of the proposed method are validated by using the YG-25 on-board side slither data. The results prove that the mean streaking metrics of relative correction images of YG-25 is better 0.07%, the noticeable striping artifact and residual noise are removed, the calibration accuracy of side slither technique based on non-uniform features is superior to life image statistics of sensor's life span.

  4. A calibration facility for radon fluxmeter

    International Nuclear Information System (INIS)

    Li Xianjie; Qiu Shoukang; Zhou Jianliang; Liu Chunkui; Pan Jialin; Yang Mingli

    1998-01-01

    Calibration facilities for radon fluxmeter with three kinds of different emanation medium have been developed. The stability of radon flux is 5%, 9% (RSD) respectively. The uniformity of radon flux is 4.5%, 8.5% (RSD) respectively. These specifications fulfill the calibration requirement for radon fluxmeter. The determination of radon flux of facility takes full account of eliminating the main error source-attenuation effect (including leakage and back diffusion etc.): not only prevent attenuation and make a relevant correction. Therefore the accuracy of determination is assured. The calibration, intercomparison of radon flux meter and the quantitatively evaluation on the measurement method of radon flux are made to be possible by the successful establishment of this facility. (author)

  5. FIMS Wavelength Calibration via Airglow Line Observations

    Directory of Open Access Journals (Sweden)

    Dae-Hee Lee

    2004-12-01

    Full Text Available Far-ultraviolet Imaging Spectrograph (FIMS is the main payload of the Korea's first scientific micro satellite STSAT-1, which was launched at Sep. 27 2003 successfully. Major objective of FIMS is observing hot gas in the Galaxy in FUV bands to diagnose the energy flow models of the interstellar medium. Supernova remnants, molecular clouds, and Aurora emission in the geomagnetic pole regions are specific targets for pointing observation. Although the whole system was calibrated before launch, it is essential to perform on-orbit calibration for data analysis. For spectral calibration, we observed airglow lines in the atmosphere since they provide good spectral references. We identify and compare the observed airglow lines with model calculations, and correct the spectral distortion appeared in the detector system to improve the spectral resolution of the system.

  6. Development of nano-roughness calibration standards

    International Nuclear Information System (INIS)

    Baršić, Gorana; Mahović, Sanjin; Zorc, Hrvoje

    2012-01-01

    At the Laboratory for Precise Measurements of Length, currently the Croatian National Laboratory for Length, unique nano-roughness calibration standards were developed, which have been physically implemented in cooperation with the company MikroMasch Trading OU and the Ruđer Bošković Institute. In this paper, a new design for a calibration standard with two measuring surfaces is presented. One of the surfaces is for the reproduction of roughness parameters, while the other is for the traceability of length units below 50 nm. The nominal values of the groove depths on these measuring surfaces are the same. Thus, a link between the measuring surfaces has been ensured, which makes these standards unique. Furthermore, the calibration standards available on the market are generally designed specifically for individual groups of measuring instrumentation, such as interferometric microscopes, stylus instruments, scanning electron microscopes (SEM) or scanning probe microscopes. In this paper, a new design for nano-roughness standards has been proposed for use in the calibration of optical instruments, as well as for stylus instruments, SEM, atomic force microscopes and scanning tunneling microscopes. Therefore, the development of these new nano-roughness calibration standards greatly contributes to the reproducibility of the results of groove depth measurement as well as the 2D and 3D roughness parameters obtained by various measuring methods. (paper)

  7. Calibration of triaxial fluxgate gradiometer

    International Nuclear Information System (INIS)

    Vcelak, Jan

    2006-01-01

    The description of simple and fast calibration procedures used for double-probe triaxial fluxgate gradiometer is provided in this paper. The calibration procedure consists of three basic steps. In the first step both probes are calibrated independently in order to reach constant total field reading in every position. Both probes are numerically aligned in the second step in order that the gradient reading is zero in homogenous magnetic field. The third step consists of periodic drift calibration during measurement. The results and detailed description of each calibration step are presented and discussed in the paper. The gradiometer is finally verified during the detection of the metal object in the measuring grid

  8. Primary calibration in acoustics metrology

    International Nuclear Information System (INIS)

    Milhomem, T A Bacelar; Soares, Z M Defilippo

    2015-01-01

    SI unit in acoustics is realized by the reciprocity calibrations of laboratory standard microphones in pressure field, free field and diffuse field. Calibrations in pressure field and in free field are already consolidated and the Inmetro already done them. Calibration in diffuse field is not yet consolidated, however, some national metrology institutes, including Inmetro, are conducting researches on this subject. This paper presents the reciprocity calibration, the results of Inmetro in recent key comparisons and the research that is being developed for the implementation of reciprocity calibration in diffuse field

  9. Neutron dosemeter responses in workplace fields and the implications of using realistic neutron calibration fields

    International Nuclear Information System (INIS)

    Thomas, D.J.; Horwood, N.; Taylor, G.C.

    1999-01-01

    The use of realistic neutron calibration fields to overcome some of the problems associated with the response functions of presently available dosemeters, both area survey instruments and personal dosemeters, has been investigated. Realistic calibration fields have spectra which, compared to conventional radionuclide source based calibration fields, more closely match those of the workplace fields in which dosemeters are used. Monte Carlo simulations were performed to identify laboratory systems which would produce appropriate workplace-like calibration fields. A detailed analysis was then undertaken of the predicted under- and over-responses of dosemeters in a wide selection of measured workplace field spectra assuming calibration in a selection of calibration fields. These included both conventional radionuclide source calibration fields, and also several proposed realistic calibration fields. The present state of the art for dosemeter performance, and the possibilities of improving accuracy by using realistic calibration fields are both presented. (author)

  10. Actuator-Assisted Calibration of Freehand 3D Ultrasound System.

    Science.gov (United States)

    Koo, Terry K; Silvia, Nathaniel

    2018-01-01

    Freehand three-dimensional (3D) ultrasound has been used independently of other technologies to analyze complex geometries or registered with other imaging modalities to aid surgical and radiotherapy planning. A fundamental requirement for all freehand 3D ultrasound systems is probe calibration. The purpose of this study was to develop an actuator-assisted approach to facilitate freehand 3D ultrasound calibration using point-based phantoms. We modified the mathematical formulation of the calibration problem to eliminate the need of imaging the point targets at different viewing angles and developed an actuator-assisted approach/setup to facilitate quick and consistent collection of point targets spanning the entire image field of view. The actuator-assisted approach was applied to a commonly used cross wire phantom as well as two custom-made point-based phantoms (original and modified), each containing 7 collinear point targets, and compared the results with the traditional freehand cross wire phantom calibration in terms of calibration reproducibility, point reconstruction precision, point reconstruction accuracy, distance reconstruction accuracy, and data acquisition time. Results demonstrated that the actuator-assisted single cross wire phantom calibration significantly improved the calibration reproducibility and offered similar point reconstruction precision, point reconstruction accuracy, distance reconstruction accuracy, and data acquisition time with respect to the freehand cross wire phantom calibration. On the other hand, the actuator-assisted modified "collinear point target" phantom calibration offered similar precision and accuracy when compared to the freehand cross wire phantom calibration, but it reduced the data acquisition time by 57%. It appears that both actuator-assisted cross wire phantom and modified collinear point target phantom calibration approaches are viable options for freehand 3D ultrasound calibration.

  11. The CHEOPS calibration bench

    Science.gov (United States)

    Wildi, F.; Chazelas, B.; Deline, A.; Sarajlic, M.; Sordet, M.

    2017-09-01

    CHEOPS is an ESA Class S Mission aiming at the characterization of exoplanets through the precise measurement of their radius, using the transit method [1]. To achieve this goal, the payload is designed to be a high precision "absolute" photometer, looking at one star at a time. It will be able to cover la large fraction of the sky by repointing. Its launch is expected at the end of 2017 [2, this conference]. CHEOPS' main science is the measure of the transit of exoplanets of radius ranging from 1 to 6 Earth radii orbiting bright stars. The required photometric stability to reach this goal is of 20 ppm in 6 hours for a 9th magnitude star. The CHEOPS' only instrument is a Ritchey-Chretien style telescope with 300 mm effective aperture diameter, which provides a defocussed image of the target star on a single frame-transfer backside illuminated CCD detector cooled to -40°C and stabilized within 10 mK [2]. CHEOPS being in a LEO, it is equipped with a high performance baffle. The spacecraft platform provides a pointing stability of < 2 arcsec rms. This relatively modest pointing performance makes high quality flat-fielding necessary In the rest of this article we will refer to the only CHEOPS instrument simply as "CHEOP" Its behavior will be calibrated thoroughly on the ground and only a small subset of the calibrations can be redone in flight. The main focuses of the calibrations are the photonic gain stability and sensibility to the environment variations and the Flat field that has to be known at a precision better than 0.1%.

  12. Radionuclide calibrators performance evaluation

    International Nuclear Information System (INIS)

    Mora Ramirez, E.; Zeledon Fonseca, P.; Jimenez Cordero, M.

    2008-01-01

    Radionuclide calibrators are used to estimate accurately activity prior to administration to a patient, so it is very important that this equipment meets its performance requirements. The purpose of this paper is to compare the commercially available 'Calicheck' (Calcorp. Inc), used to assess linearity, versus the well-known source decay method, and also to show our results after performing several recommended quality control tests. The parameters that we wanted to evaluate were carried on using the Capintec CRC-15R and CRC-15 β radionuclide calibrators. The evaluated tests were: high voltage, display, zero adjust, background, reproducibility, source constancy, accuracy, precision and linearity. The first six tests were evaluated on the daily practice, here we analyzed the 2007 recorded data; and the last three were evaluated once a year. During the daily evaluation both calibrators performance were satisfactory comparing with the manufacture's requirements. The accuracy test show result within the ± 10% allowed for a field instrument. Precision performance is within the ± 1 % allowed. On the other hand, the linearity test shows that using the source decay method the relative coefficient is 0.9998, for both equipment and using the Calicheck the relative coefficient is 0.997. However, looking the percentage of error, during the 'Calicheck' test, its range goes from 0.0 % up to -25.35%, and using the source decay method, the range goes from 0.0 % up to -31.05 %, taking into account both instruments. Checking the 'Calicheck' results we can see that the results varying randomly, but using the source decay method the percentage of error increase as the source activity decrease. We conclude that both devices meet its manufactures requirements, in the case of the linearity using the decay method, decreasing the activity source, increasing the percentage of error, this may happen because of the equipment age. (author)

  13. Self-calibrating interferometer

    International Nuclear Information System (INIS)

    Nussmeier, T.A.

    1982-01-01

    A self-calibrating interferometer is disclosed which forms therein a pair of Michelson interferometers with one beam length of each Michelson interferometer being controlled by a common phase shifter. The transfer function measured from the phase shifter to either of a pair of detectors is sinusoidal with a full cycle for each half wavelength of phase shifter travel. The phase difference between these two sinusoidal detector outputs represents the optical phase difference between a path of known distance and a path of unknown distance

  14. OECD/NRC Benchmark Based on NUPEC PWR Sub-channel and Bundle Test (PSBT). Volume I: Experimental Database and Final Problem Specifications

    International Nuclear Information System (INIS)

    Rubin, A.; Schoedel, A.; Avramova, M.; Utsuno, H.; Bajorek, S.; Velazquez-Lozada, A.

    2012-01-01

    The need to refine models for best-estimate calculations, based on good-quality experimental data, has been expressed in many recent meetings in the field of nuclear applications. The needs arising in this respect should not be limited to the currently available macroscopic methods but should be extended to next-generation analysis techniques that focus on more microscopic processes. One of the most valuable databases identified for the thermal-hydraulics modelling was developed by the Nuclear Power Engineering Corporation (NUPEC), Japan, which includes sub-channel void fraction and departure from nucleate boiling (DNB) measurements in a representative Pressurised Water Reactor (PWR) fuel assembly. Part of this database has been made available for this international benchmark activity entitled 'NUPEC PWR Sub-channel and Bundle Tests (PSBT) benchmark'. This international project has been officially approved by the Japanese Ministry of Economy, Trade, and Industry (METI), the US Nuclear Regulatory Commission (NRC) and endorsed by the OECD/NEA. The benchmark team has been organised based on the collaboration between Japan and the USA. A large number of international experts have agreed to participate in this programme. The fine-mesh high-quality sub-channel void fraction and departure from nucleate boiling data encourages advancement in understanding and modelling complex flow behaviour in real bundles. Considering that the present theoretical approach is relatively immature, the benchmark specification is designed so that it will systematically assess and compare the participants' analytical models on the prediction of detailed void distributions and DNB. The development of truly mechanistic models for DNB prediction is currently underway. The benchmark problem includes both macroscopic and microscopic measurement data. In this context, the sub-channel grade void fraction data are regarded as the macroscopic data and the digitised computer graphic images are the

  15. Dosimetry and Calibration Section

    International Nuclear Information System (INIS)

    Otto, T.

    1999-01-01

    The Dosimetry and Calibration Section fulfils two tasks within CERN's Radiation Protection Group: the Individual Dosimetry Service monitors more than 5000 persons potentially exposed to ionizing radiation on the CERN sites, and the Calibration Laboratory verifies throughout the year, at regular intervals, over 1000 instruments, monitors, and electronic dosimeters used by RP Group. The establishment of a Quality Assurance System for the Individual Dosimetry Service, a requirement of the new Swiss Ordinance for personal dosimetry, put a considerable workload on the section. Together with an external consultant it was decided to identify and then describe the different 'processes' of the routine work performed in the dosimetry service. The resulting Quality Manual was submitted to the Federal Office for Public Health in Bern in autumn. The CERN Individual Dosimetry Service will eventually be officially endorsed after a successful technical test in March 1999. On the technical side, the introduction of an automatic development machine for gamma films was very successful. It processes the dosimetric films without an operator being present, and its built-in regeneration mechanism keeps the concentration of the processing chemicals at a constant level

  16. Piezoelectric trace vapor calibrator

    International Nuclear Information System (INIS)

    Verkouteren, R. Michael; Gillen, Greg; Taylor, David W.

    2006-01-01

    The design and performance of a vapor generator for calibration and testing of trace chemical sensors are described. The device utilizes piezoelectric ink-jet nozzles to dispense and vaporize precisely known amounts of analyte solutions as monodisperse droplets onto a hot ceramic surface, where the generated vapors are mixed with air before exiting the device. Injected droplets are monitored by microscope with strobed illumination, and the reproducibility of droplet volumes is optimized by adjustment of piezoelectric wave form parameters. Complete vaporization of the droplets occurs only across a 10 deg. C window within the transition boiling regime of the solvent, and the minimum and maximum rates of trace analyte that may be injected and evaporated are determined by thermodynamic principles and empirical observations of droplet formation and stability. By varying solution concentrations, droplet injection rates, air flow, and the number of active nozzles, the system is designed to deliver--on demand--continuous vapor concentrations across more than six orders of magnitude (nominally 290 fg/l to 1.05 μg/l). Vapor pulses containing femtogram to microgram quantities of analyte may also be generated. Calibrated ranges of three explosive vapors at ng/l levels were generated by the device and directly measured by ion mobility spectrometry (IMS). These data demonstrate expected linear trends within the limited working range of the IMS detector and also exhibit subtle nonlinear behavior from the IMS measurement process

  17. A Simple Accelerometer Calibrator

    International Nuclear Information System (INIS)

    Salam, R A; Islamy, M R F; Khairurrijal; Munir, M M; Latief, H; Irsyam, M

    2016-01-01

    High possibility of earthquake could lead to the high number of victims caused by it. It also can cause other hazards such as tsunami, landslide, etc. In that case it requires a system that can examine the earthquake occurrence. Some possible system to detect earthquake is by creating a vibration sensor system using accelerometer. However, the output of the system is usually put in the form of acceleration data. Therefore, a calibrator system for accelerometer to sense the vibration is needed. In this study, a simple accelerometer calibrator has been developed using 12 V DC motor, optocoupler, Liquid Crystal Display (LCD) and AVR 328 microcontroller as controller system. The system uses the Pulse Wave Modulation (PWM) form microcontroller to control the motor rotational speed as response to vibration frequency. The frequency of vibration was read by optocoupler and then those data was used as feedback to the system. The results show that the systems could control the rotational speed and the vibration frequencies in accordance with the defined PWM. (paper)

  18. Measurement quality assurance for beta particle calibrations at NIST

    International Nuclear Information System (INIS)

    Soares, C.G.; Pruitt, J.S.

    1993-01-01

    Standardized beta-particle fields have been established in an international standard and have been adopted for use in several U.S. dosimeter and instrument testing standards. Calibration methods and measurement quality assurance procedures employed at the National Institute of Standards and Technology (NIST) for beta-particle calibrations in these reference fields are discussed. The calibration facility including the NIST-automated extrapolation ionization chamber is described, and some sample results of calibrations are shown. Methods for establishing and maintaining traceability to NIST of secondary laboratories are discussed. Currently, there are problems in finding a good method for routine testing of traceability to NIST. Some examples of past testing methods are given and solutions to this problem are proposed

  19. Measurement quality assurance for beta particle calibrations at NIST

    Energy Technology Data Exchange (ETDEWEB)

    Soares, C.G.; Pruitt, J.S. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    1993-12-31

    Standardized beta-particle fields have been established in an international standard and have been adopted for use in several U.S. dosimeter and instrument testing standards. Calibration methods and measurement quality assurance procedures employed at the National Institute of Standards and Technology (NIST) for beta-particle calibrations in these reference fields are discussed. The calibration facility including the NIST-automated extrapolation ionization chamber is described, and some sample results of calibrations are shown. Methods for establishing and maintaining traceability to NIST of secondary laboratories are discussed. Currently, there are problems in finding a good method for routine testing of traceability to NIST. Some examples of past testing methods are given and solutions to this problem are proposed.

  20. On chromatic and geometrical calibration

    DEFF Research Database (Denmark)

    Folm-Hansen, Jørgen

    1999-01-01

    The main subject of the present thesis is different methods for the geometrical and chromatic calibration of cameras in various environments. For the monochromatic issues of the calibration we present the acquisition of monochrome images, the classic monochrome aberrations and the various sources...... the correct interpolation method is described. For the chromatic issues of calibration we present the acquisition of colour and multi-spectral images, the chromatic aberrations and the various lens/camera based non-uniformities of the illumination of the image plane. It is described how the monochromatic...... to design calibration targets for both geometrical and chromatic calibration are described. We present some possible systematical errors on the detection of the objects in the calibration targets, if viewed in a non orthogonal angle, if the intensities are uneven or if the image blurring is uneven. Finally...

  1. Development of portable flow calibrator

    International Nuclear Information System (INIS)

    Akiyama, Kiyomitsu; Iijima, Nobuo

    1995-01-01

    In the nuclear facilities, air sniffer system is often utilized to evaluate atmospheric concentration of radioactivity in the working environment. The system collects airborne dust on the filter during some sampling period. In this method, total air flow during the sampling period is an important parameter to evaluate the radioactivity concentration correctly. Therefore, calibration for the flow meter of air sniffer system must be done periodically according to Japan Industry Standards (JIS). As we have had to available device to calibrate the flow meter in the working area, we had to remove the flow meters from the installed place and carry them to another place where calibration can be made. This work required a great deal of labor. Now we have developed a portable flow calibrator for air sniffer system which enables us to make in-site calibration of the flow meter in the working area more easily. This report describes the outline of portable flow calibrator and it's experimental results. (author)

  2. Novel crystal timing calibration method based on total variation

    Science.gov (United States)

    Yu, Xingjian; Isobe, Takashi; Watanabe, Mitsuo; Liu, Huafeng

    2016-11-01

    A novel crystal timing calibration method based on total variation (TV), abbreviated as ‘TV merge’, has been developed for a high-resolution positron emission tomography (PET) system. The proposed method was developed for a system with a large number of crystals, it can provide timing calibration at the crystal level. In the proposed method, the timing calibration process was formulated as a linear problem. To robustly optimize the timing resolution, a TV constraint was added to the linear equation. Moreover, to solve the computer memory problem associated with the calculation of the timing calibration factors for systems with a large number of crystals, the merge component was used for obtaining the crystal level timing calibration values. Compared with other conventional methods, the data measured from a standard cylindrical phantom filled with a radioisotope solution was sufficient for performing a high-precision crystal-level timing calibration. In this paper, both simulation and experimental studies were performed to demonstrate the effectiveness and robustness of the TV merge method. We compare the timing resolutions of a 22Na point source, which was located in the field of view (FOV) of the brain PET system, with various calibration techniques. After implementing the TV merge method, the timing resolution improved from 3.34 ns at full width at half maximum (FWHM) to 2.31 ns FWHM.

  3. Nuclear fuel technology - Tank calibration and volume determination for nuclear materials accountancy - Part 2: Data standardization for tank calibration

    International Nuclear Information System (INIS)

    2007-01-01

    Measurements of the volume and height of liquid in a process accountancy tank are often made in order to estimate or verify the tank's calibration or volume measurement equation. The calibration equation relates the response of the tank's measurement system to some independent measure of tank volume. The ultimate purpose of the calibration exercise is to estimate the tank's volume measurement equation (the inverse of the calibration equation), which relates tank volume to measurement system response. In this part of ISO 18213, it is assumed that the primary measurement-system response variable is liquid height and that the primary measure of liquid content is volume. This part of ISO 18213 presents procedures for standardizing a set of calibration data to a fixed set of reference conditions so as to minimize the effect of variations in ambient conditions that occur during the measurement process. The procedures presented herein apply generally to measurements of liquid height and volume obtained for the purpose of calibrating a tank (i.e. calibrating a tank's measurement system). When used in connection with other parts of ISO 18213, these procedures apply specifically to tanks equipped with bubbler probe systems for measuring liquid content. The standardization algorithms presented herein can be profitably applied when only estimates of ambient conditions, such as temperature, are available. However, the most reliable results are obtained when relevant ambient conditions are measured for each measurement of volume and liquid height in a set of calibration data. Information is provided on scope, physical principles, data required, calibration data, dimensional changes in the tank, multiple calibration runs and results on standardized calibration data. Four annexes inform about density of water, buoyancy corrections for mass determination, determination of tank heel volume and statistical method for aligning data from several calibration runs. A bibliography is

  4. Hand-eye calibration using a target registration error model.

    Science.gov (United States)

    Chen, Elvis C S; Morgan, Isabella; Jayarathne, Uditha; Ma, Burton; Peters, Terry M

    2017-10-01

    Surgical cameras are prevalent in modern operating theatres and are often used as a surrogate for direct vision. Visualisation techniques (e.g. image fusion) made possible by tracking the camera require accurate hand-eye calibration between the camera and the tracking system. The authors introduce the concept of 'guided hand-eye calibration', where calibration measurements are facilitated by a target registration error (TRE) model. They formulate hand-eye calibration as a registration problem between homologous point-line pairs. For each measurement, the position of a monochromatic ball-tip stylus (a point) and its projection onto the image (a line) is recorded, and the TRE of the resulting calibration is predicted using a TRE model. The TRE model is then used to guide the placement of the calibration tool, so that the subsequent measurement minimises the predicted TRE. Assessing TRE after each measurement produces accurate calibration using a minimal number of measurements. As a proof of principle, they evaluated guided calibration using a webcam and an endoscopic camera. Their endoscopic camera results suggest that millimetre TRE is achievable when at least 15 measurements are acquired with the tracker sensor ∼80 cm away on the laparoscope handle for a target ∼20 cm away from the camera.

  5. Simbol-X Telescope Scientific Calibrations: Requirements and Plans

    International Nuclear Information System (INIS)

    Malaguti, G.; Raimondi, L.; Trifoglio, M.; Angelini, L.; Moretti, A.

    2009-01-01

    The Simbol-X telescope characteristics and the mission scientific requirements impose a challenging calibration plan with a number of unprecedented issues. The 20 m focal length implies for the incoming X-ray beam a divergence comparable to the incidence angle of the mirror surface also for 100 m-long facilities. Moreover this is the first time that a direct focussing X-ray telescope will be calibrated on an energy band covering about three decades, and with a complex focal plane. These problems require a careful plan and organization of the measurements, together with an evaluation of the calibration needs in terms of both hardware and software.

  6. Simbol-X Telescope Scientific Calibrations: Requirements and Plans

    Science.gov (United States)

    Malaguti, G.; Angelini, L.; Raimondi, L.; Moretti, A.; Trifoglio, M.

    2009-05-01

    The Simbol-X telescope characteristics and the mission scientific requirements impose a challenging calibration plan with a number of unprecedented issues. The 20 m focal length implies for the incoming X-ray beam a divergence comparable to the incidence angle of the mirror surface also for 100 m-long facilities. Moreover this is the first time that a direct focussing X-ray telescope will be calibrated on an energy band covering about three decades, and with a complex focal plane. These problems require a careful plan and organization of the measurements, together with an evaluation of the calibration needs in terms of both hardware and software.

  7. Sensitivity and specificity of a brief personality screening instrument in predicting future substance use, emotional, and behavioral problems: 18-month predictive validity of the Substance Use Risk Profile Scale.

    Science.gov (United States)

    Castellanos-Ryan, Natalie; O'Leary-Barrett, Maeve; Sully, Laura; Conrod, Patricia

    2013-01-01

    This study assessed the validity, sensitivity, and specificity of the Substance Use Risk Profile Scale (SURPS), a measure of personality risk factors for substance use and other behavioral problems in adolescence. The concurrent and predictive validity of the SURPS was tested in a sample of 1,162 adolescents (mean age: 13.7 years) using linear and logistic regressions, while its sensitivity and specificity were examined using the receiver operating characteristics curve analyses. Concurrent and predictive validity tests showed that all 4 brief scales-hopelessness (H), anxiety sensitivity (AS), impulsivity (IMP), and sensation seeking (SS)-were related, in theoretically expected ways, to measures of substance use and other behavioral and emotional problems. Results also showed that when using the 4 SURPS subscales to identify adolescents "at risk," one can identify a high number of those who developed problems (high sensitivity scores ranging from 72 to 91%). And, as predicted, because each scale is related to specific substance and mental health problems, good specificity was obtained when using the individual personality subscales (e.g., most adolescents identified at high risk by the IMP scale developed conduct or drug use problems within the next 18 months [a high specificity score of 70 to 80%]). The SURPS is a valuable tool for identifying adolescents at high risk for substance misuse and other emotional and behavioral problems. Implications of findings for the use of this measure in future research and prevention interventions are discussed. Copyright © 2012 by the Research Society on Alcoholism.

  8. Active Subspace Methods for Data-Intensive Inverse Problems

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Qiqi [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2017-04-27

    The project has developed theory and computational tools to exploit active subspaces to reduce the dimension in statistical calibration problems. This dimension reduction enables MCMC methods to calibrate otherwise intractable models. The same theoretical and computational tools can also reduce the measurement dimension for calibration problems that use large stores of data.

  9. Absolute calibration and beam background of the Squid Polarimeter

    International Nuclear Information System (INIS)

    Blaskiewicz, M.M.; Cameron, P.R.; Shea, T.J.

    1996-01-01

    The problem of beam background in Squid Polarimetry is not without residual benefits. The authors may deliberately generate beam background by gently kicking the beam at the spin tune frequency. This signal may be used to accomplish a simple and accurate absolute calibration of the polarimeter. The authors present details of beam background calculations and their application to polarimeter calibration, and suggest a simple proof-of-principle accelerator experiment

  10. An Integrated Calibration Technique for Stereo Vision Systems (PREPRINT)

    Science.gov (United States)

    2010-03-01

    technique for stereo vision systems has been developed. To demonstrate and evaluate this calibration technique, multiple Wii Remotes (Wiimotes) from Nintendo ...from Nintendo were used to form stereo vision systems to perform 3D motion capture in real time. This integrated technique is a two-step process...Wiimotes) used in Nintendo Wii games. Many researchers have successfully dealt with the problem of camera calibration by taking images from a 2D

  11. Bilinear Inverse Problems: Theory, Algorithms, and Applications

    Science.gov (United States)

    Ling, Shuyang

    We will discuss how several important real-world signal processing problems, such as self-calibration and blind deconvolution, can be modeled as bilinear inverse problems and solved by convex and nonconvex optimization approaches. In Chapter 2, we bring together three seemingly unrelated concepts, self-calibration, compressive sensing and biconvex optimization. We show how several self-calibration problems can be treated efficiently within the framework of biconvex compressive sensing via a new method called SparseLift. More specifically, we consider a linear system of equations y = DAx, where the diagonal matrix D (which models the calibration error) is unknown and x is an unknown sparse signal. By "lifting" this biconvex inverse problem and exploiting sparsity in this model, we derive explicit theoretical guarantees under which both x and D can be recovered exactly, robustly, and numerically efficiently. In Chapter 3, we study the question of the joint blind deconvolution and blind demixing, i.e., extracting a sequence of functions [special characters omitted] from observing only the sum of their convolutions [special characters omitted]. In particular, for the special case s = 1, it becomes the well-known blind deconvolution problem. We present a non-convex algorithm which guarantees exact recovery under conditions that are competitive with convex optimization methods, with the additional advantage of being computationally much more efficient. We discuss several applications of the proposed framework in image processing and wireless communications in connection with the Internet-of-Things. In Chapter 4, we consider three different self-calibration models of practical relevance. We show how their corresponding bilinear inverse problems can be solved by both the simple linear least squares approach and the SVD-based approach. As a consequence, the proposed algorithms are numerically extremely efficient, thus allowing for real-time deployment. Explicit theoretical

  12. SURF Model Calibration Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-10

    SURF and SURFplus are high explosive reactive burn models for shock initiation and propagation of detonation waves. They are engineering models motivated by the ignition & growth concept of high spots and for SURFplus a second slow reaction for the energy release from carbon clustering. A key feature of the SURF model is that there is a partial decoupling between model parameters and detonation properties. This enables reduced sets of independent parameters to be calibrated sequentially for the initiation and propagation regimes. Here we focus on a methodology for tting the initiation parameters to Pop plot data based on 1-D simulations to compute a numerical Pop plot. In addition, the strategy for tting the remaining parameters for the propagation regime and failure diameter is discussed.

  13. Calibration of Nanopositioning Stages

    Directory of Open Access Journals (Sweden)

    Ning Tan

    2015-12-01

    Full Text Available Accuracy is one of the most important criteria for the performance evaluation of micro- and nanorobots or systems. Nanopositioning stages are used to achieve the high positioning resolution and accuracy for a wide and growing scope of applications. However, their positioning accuracy and repeatability are not well known and difficult to guarantee, which induces many drawbacks for many applications. For example, in the mechanical characterisation of biological samples, it is difficult to perform several cycles in a repeatable way so as not to induce negative influences on the study. It also prevents one from controlling accurately a tool with respect to a sample without adding additional sensors for closed loop control. This paper aims at quantifying the positioning repeatability and accuracy based on the ISO 9283:1998 standard, and analyzing factors influencing positioning accuracy onto a case study of 1-DoF (Degree-of-Freedom nanopositioning stage. The influence of thermal drift is notably quantified. Performances improvement of the nanopositioning stage are then investigated through robot calibration (i.e., open-loop approach. Two models (static and adaptive models are proposed to compensate for both geometric errors and thermal drift. Validation experiments are conducted over a long period (several days showing that the accuracy of the stage is improved from typical micrometer range to 400 nm using the static model and even down to 100 nm using the adaptive model. In addition, we extend the 1-DoF calibration to multi-DoF with a case study of a 2-DoF nanopositioning robot. Results demonstrate that the model efficiently improved the 2D accuracy from 1400 nm to 200 nm.

  14. CERN radiation protection (RP) calibration facilities

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi, Fabio

    2016-04-14

    Radiation protection calibration facilities are essential to ensure the correct operation of radiation protection instrumentation. Calibrations are performed in specific radiation fields according to the type of instrument to be calibrated: neutrons, photons, X-rays, beta and alpha particles. Some of the instruments are also tested in mixed radiation fields as often encountered close to high-energy particle accelerators. Moreover, calibration facilities are of great importance to evaluate the performance of prototype detectors; testing and measuring the response of a prototype detector to well-known and -characterized radiation fields contributes to improving and optimizing its design and capabilities. The CERN Radiation Protection group is in charge of performing the regular calibrations of all CERN radiation protection devices; these include operational and passive dosimeters, neutron and photon survey-meters, and fixed radiation detectors to monitor the ambient dose equivalent, H*(10), inside CERN accelerators and at the CERN borders. A new state-of-the-art radiation protection calibration facility was designed, constructed and commissioned following the related ISO recommendations to replace the previous ageing (more than 30 years old) laboratory. In fact, the new laboratory aims also at the official accreditation according to the ISO standards in order to be able to release certified calibrations. Four radiation fields are provided: neutrons, photons and beta sources and an X-ray generator. Its construction did not only involve a pure civil engineering work; many radiation protection studies were performed to provide a facility that could answer the CERN calibration needs and fulfill all related safety requirements. Monte Carlo simulations have been confirmed to be a valuable tool for the optimization of the building design, the radiation protection aspects, e.g. shielding, and, as consequence, the overall cost. After the source and irradiator installation

  15. Radiological Calibration and Standards Facility

    Data.gov (United States)

    Federal Laboratory Consortium — PNNL maintains a state-of-the-art Radiological Calibration and Standards Laboratory on the Hanford Site at Richland, Washington. Laboratory staff provide expertise...

  16. Portable compact multifunction IR calibrator

    International Nuclear Information System (INIS)

    Wyatt, C.L.; Jacobsen, L.; Steed, A.

    1988-01-01

    A compact portable multifunction calibrator designed for future sensor systems is described which enables a linearity calibration for all detectors simultaneously using a near small-area source, a high-resolution mapping of the focal plane with 10 microrad setability and with a blur of less than 100 microrad, system spectral response calibration (radiometer) using a Michelson interferometer source, relative spectral response (spectrometer) using high-temperature external commercial blackbody simulators, and an absolute calibration using an internal low-temperature extended-area source. 5 references

  17. Photometric Calibration of Consumer Video Cameras

    Science.gov (United States)

    Suggs, Robert; Swift, Wesley, Jr.

    2007-01-01

    Equipment and techniques have been developed to implement a method of photometric calibration of consumer video cameras for imaging of objects that are sufficiently narrow or sufficiently distant to be optically equivalent to point or line sources. Heretofore, it has been difficult to calibrate consumer video cameras, especially in cases of image saturation, because they exhibit nonlinear responses with dynamic ranges much smaller than those of scientific-grade video cameras. The present method not only takes this difficulty in stride but also makes it possible to extend effective dynamic ranges to several powers of ten beyond saturation levels. The method will likely be primarily useful in astronomical photometry. There are also potential commercial applications in medical and industrial imaging of point or line sources in the presence of saturation.This development was prompted by the need to measure brightnesses of debris in amateur video images of the breakup of the Space Shuttle Columbia. The purpose of these measurements is to use the brightness values to estimate relative masses of debris objects. In most of the images, the brightness of the main body of Columbia was found to exceed the dynamic ranges of the cameras. A similar problem arose a few years ago in the analysis of video images of Leonid meteors. The present method is a refined version of the calibration method developed to solve the Leonid calibration problem. In this method, one performs an endto- end calibration of the entire imaging system, including not only the imaging optics and imaging photodetector array but also analog tape recording and playback equipment (if used) and any frame grabber or other analog-to-digital converter (if used). To automatically incorporate the effects of nonlinearity and any other distortions into the calibration, the calibration images are processed in precisely the same manner as are the images of meteors, space-shuttle debris, or other objects that one seeks to

  18. BXS Re-calibration

    International Nuclear Information System (INIS)

    Welch, J.

    2010-01-01

    Early in the commissioning it was noticed by Cecile Limborg that the calibration of the BXS spectrometer magnet seemed to be different from the strength of the BX01/BX02 magnets. First the BX01/BX02 currents were adjusted to 135 MeV and the beam energy was adjusted to make the horizontal orbit flat. Then BX01/BX02 magnets were switched off and BXS was adjusted to make the horizontal orbit in the spectrometer line flat, without changing the energy of the beam. The result was that about 140-141 MeV were required on the BXS magnet. This measurement was repeated several times by others with the same results. It was not clear what was causing the error: magnet strength or layout. A position error of about 19 mm of the BXS magnet could explain the difference. Because there was a significant misalignment of the vacuum chamber in the BXS line, the alignment of the whole spectrometer line was checked. The vacuum chamber was corrected, but the magnets were found to be in the proper alignment. So we were left with one (or conceivably two) magnet calibration errors. Because BXS is a wedged shaped magnet, the bend angle depends on the horizontal position of the incoming beam. As mentioned, an offset of the beam position of 19 mm would increase or decrease the bend angle roughly by the ratio of 135/141. The figure of 19 mm is special and caused a considerable confusion during the design and measurement of the BXS magnet. This is best illustrated in Figure 1 which was taken out of the BXS Traveler document. The distance between the horizontal midplanes of the poles and the apex of the beam path was chosen to be 19 mm so the beam is close to the good field region throughout its entire path. Thus it seemed possible that there was an error that resulted in the beam not being on this trajectory, or conversely, that the magnetic measurements were done on the wrong trajectory and the magnet was then mis-calibrated. Mechanical measurements of the vacuum chamber made in the tunnel

  19. Direct calibration of PICKY-designed microarrays

    Directory of Open Access Journals (Sweden)

    Ronald Pamela C

    2009-10-01

    Full Text Available Abstract Background Few microarrays have been quantitatively calibrated to identify optimal hybridization conditions because it is difficult to precisely determine the hybridization characteristics of a microarray using biologically variable cDNA samples. Results Using synthesized samples with known concentrations of specific oligonucleotides, a series of microarray experiments was conducted to evaluate microarrays designed by PICKY, an oligo microarray design software tool, and to test a direct microarray calibration method based on the PICKY-predicted, thermodynamically closest nontarget information. The complete set of microarray experiment results is archived in the GEO database with series accession number GSE14717. Additional data files and Perl programs described in this paper can be obtained from the website http://www.complex.iastate.edu under the PICKY Download area. Conclusion PICKY-designed microarray probes are highly reliable over a wide range of hybridization temperatures and sample concentrations. The microarray calibration method reported here allows researchers to experimentally optimize their hybridization conditions. Because this method is straightforward, uses existing microarrays and relatively inexpensive synthesized samples, it can be used by any lab that uses microarrays designed by PICKY. In addition, other microarrays can be reanalyzed by PICKY to obtain the thermodynamically closest nontarget information for calibration.

  20. Calibration of Cryogenic Thermometers for the LHC

    CERN Document Server

    Balle, Ch; Vauthier, N; Thermeau, JP

    2008-01-01

    6000 cryogenic temperature sensors of resistive type covering the range from room temperature down to 1.6 K are installed on the LHC machine. In order to meet the stringent requirements on temperature control of the superconducting magnets, each single sensor needs to be calibrated individually. In the framework of a special contribution, IPN (Institut de Physique Nucléaire) in Orsay, France built and operated a calibration facility with a throughput of 80 thermometers per week. After reception from the manufacturer, the thermometer is first assembled onto a support specific to the measurement environment, and then thermally cycled ten times and calibrated at least once from 1.6 to 300 K. The procedure for each of these interventions includes various measurements and the acquired data is recorded in an ORACLE®-database. Furthermore random calibrations on some samples are executed at CERN to crosscheck the coherence between the approximation data obtained by both IPN and CERN. In the range of 1.5 K to 30 K...

  1. Phase calibration strategies for synchrotron RF signals

    Energy Technology Data Exchange (ETDEWEB)

    Andreev, Aleksandr [TEMF, Technische Universitaet Darmstadt (Germany); Klingbeil, Harald [TEMF, Technische Universitaet Darmstadt (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Lens, Dieter [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany)

    2016-07-01

    For the FAIR facility that is currently under construction, the beam quality requirements impose several demands on the low-level RF (LLRF) systems. For example the phase error of the gap voltage of a specific RF cavity must be less than 1 . The RF reference signals for the FAIR synchrotron RF cavity systems are generated by direct digital synthesis modules (DDS) mounted in one crate called Group-DDS. In order to allow performing various multi-harmonic operations, each DDS unit operates at a certain mode defined by the harmonic number that can be changed during the operation. Since the DDS modules generate reference RF signals for different LLRF systems, the precise calibration of units to compensate the different phase response is of importance. The currently used calibration procedure is done with a fixed harmonic number for each module and uses the DDS module configured to the highest harmonic number as a reference. If the harmonic number of the DDS module is changed, one then has to repeat the calibration for the new values. Therefore, a new calibration method with respect to the absolute phases of DDS modules is under development and will be presented.

  2. ATLAS Tile Calorimeter time calibration, monitoring and performance

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00075913; The ATLAS collaboration

    2016-01-01

    The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the central region of the ATLAS experiment at the LHC. This sampling device is made of plastic scintillating tiles alternated with iron plates and its response is calibrated to electromagnetic scale by means of several dedicated calibration systems. The accurate time calibration is important for the energy reconstruction, non-collision background removal as well as for specific physics analyses. The initial time calibration with so-called splash events and subsequent fine-tuning with collision data are presented. The monitoring of the time calibration with laser system and physics collision data is discussed as well as the corrections for sudden changes performed still before the recorded data are processed for physics analyses. Finally, the time resolution as measured with jets and isolated muons particles is presented.

  3. Exposure-rate calibration using large-area calibration pads

    International Nuclear Information System (INIS)

    Novak, E.F.

    1988-09-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. A set of large-area, radioelement-enriched concrete pads was constructed by the DOE in 1978 at the Walker Field Airport in Grand Junction for use as calibration standards for airborne gamma-ray spectrometer systems. The use of these pads was investigated by the TMC as potential calibration standards for portable scintillometers employed in measuring gamma-ray exposure rates at Uranium Mill Tailings Remedial Action (UMTRA) project sites. Data acquired on the pads using a pressurized ionization chamber (PIC) and three scintillometers are presented as an illustration of an instrumental calibration. Conclusions and recommended calibration procedures are discussed, based on the results of these data

  4. Serious diabetes-specific emotional problems in patients with type 2 diabetes who have different levels of comorbid depression: a Polish study from the European Depression in Diabetes (EDID) Research Consortium.

    Science.gov (United States)

    Kokoszka, A; Pouwer, F; Jodko, A; Radzio, R; Mućko, P; Bieńkowska, J; Kuligowska, E; Smoczyńska, O; Skłodowska, Z

    2009-10-01

    Depression is a common psychiatric problem in patients with type 2 diabetes (DM2). A common view is that the burden of having DM2 contributes to the development of depression in DM2. Aim of the present study was to compare the levels of diabetes-specific emotional problems of DM2 patients with diagnosed depression with those with a subclinical form of depression and those without depression. A cross-sectional study was conducted in 101 DM2 patients (51 men and 50 women, mean age = 63,17; SD = 10,74) who completed a standardized, structured psychiatric diagnostic interview (MINI), the Beck Depression Inventory, the Hamilton Depression Rating Scale as well as the Problem Areas in Diabetes (PAID) scale (a 20-item measure, with an overall scale measuring diabetes-related emotional distress and four subscales [negative emotions, treatment-related problems, food-related problems, lack of social support]). A depression diagnosis was made in 35% (n = 35) of the participants, 24% (n = 24) had a subclinical form of depression, 42% (n = 42) were not diagnosed with any kind of depressive disorder. Diabetes-specific emotional problems were most common in DM2 patients with a depressive disorder (significantly highest PAID score: 39) compared to patients with subclinical depression or no depression. In the group of non-depressed patients, only 14% agreed to have four or more (somewhat) serious diabetes-specific problems. In those with subclinical depression, this percentage was 42% and in those with a depressive disorder 49% (P DM2 patients with comorbid clinical depression and to a lesser extent in patients with subclinical depression, compared to non-depressed DM2 patients. Male diabetes patients with a depressive disorder are particularly vulnerable to develop high levels of diabetes-specific emotional distress. Major differences between the three groups mainly concern the diabetes-specific problems connected with the illness.

  5. LANL MTI calibration team experience

    Science.gov (United States)

    Bender, Steven C.; Atkins, William H.; Clodius, William B.; Little, Cynthia K.; Christensen, R. Wynn

    2004-01-01

    The Multispectral Thermal Imager (MTI) was designed as an imaging radiometer with absolute calibration requirements established by Department of Energy (DOE) mission goals. Particular emphasis was given to water surface temperature retrieval using two mid wave and three long wave infrared spectral bands, the fundamental requirement was a surface temperature determination of 1K at the 68% confidence level. For the ten solar reflective bands a one-sigma radiometric performance goal of 3% was established. In order to address these technical challenges a calibration facility was constructed containing newly designed sources that were calibrated at NIST. Additionally, the design of the payload and its onboard calibration system supported post launch maintenance and update of the ground calibration. The on-orbit calibration philosophy also included vicarious techniques using ocean buoys, playas and other instrumented sites; these became increasingly important subsequent to an electrical failure which disabled the onboard calibration system. This paper offers various relevant lessons learned in the eight-year process of reducing to practice the calibration capability required by the scientific mission. The discussion presented will include observations pertinent to operational and procedural issues as well as hardware experiences; the validity of some of the initial assumptions will also be explored.

  6. Field calibration of cup anemometers

    DEFF Research Database (Denmark)

    Kristensen, L.; Jensen, G.; Hansen, A.

    2001-01-01

    An outdoor calibration facility for cup anemometers, where the signals from 10 anemometers of which at least one is a reference can be can be recorded simultaneously, has been established. The results are discussed with special emphasis on the statisticalsignificance of the calibration expressions...

  7. Cobalt source calibration

    International Nuclear Information System (INIS)

    Rizvi, H.M.

    1999-01-01

    The data obtained from these tests determine the dose rate of the two cobalt sources in SRTC. Building 774-A houses one of these sources while the other resides in room C-067 of Building 773-A. The data from this experiment shows the following: (1) The dose rate of the No.2 cobalt source in Building 774-A measured 1.073 x 10 5 rad/h (June 17, 1999). The dose rate of the Shepherd Model 109 Gamma cobalt source in Building 773-A measured 9.27 x 10 5 rad/h (June 25, 1999). These rates come from placing the graduated cylinder containing the dosimeter solution in the center of the irradiation chamber. (2) Two calibration tests in the 774-A source placed the graduated cylinder with the dosimeter solution approximately 1.5 inches off center in the axial direction. This movement of the sample reduced the measured dose rate 0.92% from 1.083 x 10 5 rad/h to 1.073 x 10 5 rad/h. and (3) A similar test in the cobalt source in 773-A placed the graduated cylinder approximately 2.0 inches off center in the axial direction. This change in position reduced the measured dose rate by 10.34% from 1.036 x 10 6 to 9.27 x 10 5 . This testing used chemical dosimetry to measure the dose rate of a radioactive source. In this method, one determines the dose by the chemical change that takes place in the dosimeter. For this calibration experiment, the author used a Fricke (ferrous ammonium sulfate) dosimeter. This solution works well for dose rates to 10 7 rad/h. During irradiation of the Fricke dosimeter solution the Fe 2+ ions ionize to Fe 3+ . When this occurs, the solution acquires a slightly darker tint (not visible to the human eye). To determine the magnitude of the change in Fe ions, one places the solution in an UV-VIS Spectrophotometer. The UV-VIS Spectrophotometer measures the absorbency of the solution. Dividing the absorbency by the total time (in minutes) of exposure yields the dose rate

  8. Automation of the Calibration of Reference Dosimeters Used in Radiotherapy

    International Nuclear Information System (INIS)

    Romero Acosta, A.; Gutierrez Lores, S.

    2013-01-01

    Traceability, accuracy and consistency of radiation measurements are essential in radiation dosimetry, particularly in radiotherapy, where the outcome of treatments is highly dependent on the radiation dose delivered to patients. The role of Secondary Standard Dosimetry Laboratories (SSDLs) is crucial in providing traceable calibrations to hospitals, since these laboratories disseminate calibrations at specific radiation qualities appropriate to the use of radiation measuring instruments. These laboratories follow IAEA/WHO guidelines for calibration procedures, often being current and charge measurements described in these guidelines a tedious task. However, these measurements are usually done using modern electrometers which are equipped with a RS-232 interface that allows instrument control from a PC. This paper presents the design and employment of an automated system aimed to the measurements of the radiotherapy dosimeters calibration process for Cobalt-60 gamma rays. A software was developed using Lab View, in order to achieve the acquisition of the charge values measured, calculation of the calibration coefficient and issue of a calibration certificate. A primary data report file is filled and stored in the PC's hard disk. By using this software tool, a better control over the calibration process is achieved, it reduces the need for human intervention and it also reduces the exposure of the laboratory staff. The automated system has been used for the calibration of reference dosimeters used in radiotherapy at the Cuban Secondary Standard Dosimetry Laboratory of the Center for Radiation Protection and Hygiene (Author)

  9. CALIBRATION PROCEDURES ON OBLIQUE CAMERA SETUPS

    Directory of Open Access Journals (Sweden)

    G. Kemper

    2016-06-01

    Full Text Available Beside the creation of virtual animated 3D City models, analysis for homeland security and city planning, the accurately determination of geometric features out of oblique imagery is an important task today. Due to the huge number of single images the reduction of control points force to make use of direct referencing devices. This causes a precise camera-calibration and additional adjustment procedures. This paper aims to show the workflow of the various calibration steps and will present examples of the calibration flight with the final 3D City model. In difference to most other software, the oblique cameras are used not as co-registered sensors in relation to the nadir one, all camera images enter the AT process as single pre-oriented data. This enables a better post calibration in order to detect variations in the single camera calibration and other mechanical effects. The shown sensor (Oblique Imager is based o 5 Phase One cameras were the nadir one has 80 MPIX equipped with a 50 mm lens while the oblique ones capture images with 50 MPix using 80 mm lenses. The cameras are mounted robust inside a housing to protect this against physical and thermal deformations. The sensor head hosts also an IMU which is connected to a POS AV GNSS Receiver. The sensor is stabilized by a gyro-mount which creates floating Antenna –IMU lever arms. They had to be registered together with the Raw GNSS-IMU Data. The camera calibration procedure was performed based on a special calibration flight with 351 shoots of all 5 cameras and registered the GPS/IMU data. This specific mission was designed in two different altitudes with additional cross lines on each flying heights. The five images from each exposure positions have no overlaps but in the block there are many overlaps resulting in up to 200 measurements per points. On each photo there were in average 110 well distributed measured points which is a satisfying number for the camera calibration. In a first

  10. Liquid Krypton Calorimeter Calibration Software

    CERN Document Server

    Hughes, Christina Lindsay

    2013-01-01

    Calibration of the liquid krypton calorimeter (LKr) of the NA62 experiment is managed by a set of standalone programs, or an online calibration driver. These programs are similar to those used by NA48, but have been updated to utilize classes and translated to C++ while maintaining a common functionality. A set of classes developed to handle communication with hardware was used to develop the three standalone programs as well as the main driver program for online calibration between bursts. The main calibration driver has been designed to respond to run control commands and receive burst data, both transmitted via DIM. In order to facilitate the process of reading in calibration parameters, a serializable class has been introduced, allowing the replacement of standard text files with XML configuration files.

  11. Permanently calibrated interpolating time counter

    International Nuclear Information System (INIS)

    Jachna, Z; Szplet, R; Kwiatkowski, P; Różyc, K

    2015-01-01

    We propose a new architecture of an integrated time interval counter that provides its permanent calibration in the background. Time interval measurement and the calibration procedure are based on the use of a two-stage interpolation method and parallel processing of measurement and calibration data. The parallel processing is achieved by a doubling of two-stage interpolators in measurement channels of the counter, and by an appropriate extension of control logic. Such modification allows the updating of transfer characteristics of interpolators without the need to break a theoretically infinite measurement session. We describe the principle of permanent calibration, its implementation and influence on the quality of the counter. The precision of the presented counter is kept at a constant level (below 20 ps) despite significant changes in the ambient temperature (from −10 to 60 °C), which can cause a sevenfold decrease in the precision of the counter with a traditional calibration procedure. (paper)

  12. TIME CALIBRATED OSCILLOSCOPE SWEEP CIRCUIT

    Science.gov (United States)

    Smith, V.L.; Carstensen, H.K.

    1959-11-24

    An improved time calibrated sweep circuit is presented, which extends the range of usefulness of conventional oscilloscopes as utilized for time calibrated display applications in accordance with U. S. Patent No. 2,832,002. Principal novelty resides in the provision of a pair of separate signal paths, each of which is phase and amplitude adjustable, to connect a high-frequency calibration oscillator to the output of a sawtooth generator also connected to the respective horizontal deflection plates of an oscilloscope cathode ray tube. The amplitude and phase of the calibration oscillator signals in the two signal paths are adjusted to balance out feedthrough currents capacitively coupled at high frequencies of the calibration oscillator from each horizontal deflection plate to the vertical plates of the cathode ray tube.

  13. Calibrating the Cryogenian

    Science.gov (United States)

    MacDonald, F. A.; Schmitz, M. D.; Crowley, J. L.; Haam, E.; Huybers, P.; Cohen, P. A.; Johnston, D. T.

    2009-12-01

    The IGCP 512 sub-commission on the Neoproterozoic is currently discussing criteria for the definition of the Cryogenian period. Herein we provide new U/Pb ID-TIMS ages and carbon and oxygen isotope data from Fifteenmile and Mt. Harper Groups in the Yukon Territory that inform the basis for the placement of the basal Cryogenian “golden spike”. Our U/Pb ages are from volcanic tuffs interbedded within glaciogenic, fossiliferous, and carbonate strata. With the current lack of Neoproterozoic index fossils and the paucity of radiogenic age constraints, chemo-stratigraphic correlations are particularly important for tuning the Neoproterozoic timescale. In an effort to move beyond conventional 'wiggle matching', chemostratigraphic correlations are determined using a new statistical method1, which indicates that the resulting chemo-stratigraphic correlations are statistically significant. These results permit us to refine and integrate Neoproterozoic climate, microfossil, and geochemical proxy records both regionally and globally. The newly calibrated microfossil record points to a eukaryotic radiation roughly coincident with the Bitter Springs isotopic stage and a barren interval between the Sturtian and Marinoan glaciations. 1 Haam, E. & Huybers, P., 2009, A test for the presence of covariance between time-uncertain series of data with applications to the Dongge Cave speleothem and atmospheric radiocarbon records, Paleoceanography, in press.

  14. The nature, use and problems of historical archives for the temporal occurrence of landslides, with specific reference to the south coast of Britain, Ventnor, Isle of Wight

    Science.gov (United States)

    Ibsen, Maïa-Laura; Brunsden, Denys

    1996-04-01

    The purpose of this paper is to describe and evaluate the nature of the European historical archives which are suitable for the assessment of the temporal occurrence and forecasting within landslides studies, using the British south coast as an example. The paper is based upon the British contribution to the Environment programme EPOCH, 1991-1993. A primary requirement of a research programme on process occurrence is to determine the event frequencies on as many time and space scales as possible. Thus, the analysis of archives is, potentially, an essential preliminary to the study of the temporal occurrence of landslide events. The range of such data sources extends from isolated, fortuitously dated sites from the Quaternary assemblage, through inferred event impacts using dendrochronology or lichenometric time series to historical records of causal factors such as rainfall data and more recently, deliberately recorded packages of cumulative or continuous data. Most countries have extensive historical sources which may be of considerable value in establishing the characteristics of geomorphological processes. These include narrative in literature, prints and other artwork, terrestrial and aerial photographs, remote sensing series, newspapers, incidental statements and scientific journals and reports. These are numerous difficulties in accessing, extracting, organising, databasing and analysing such data because they are not usually collated for scientific use. Problems involve such incalculable errors as: the experience, training and conscientiousness of the observer; the editing and recording process; judging the validity of the data used and the haphazard nature of recorded events in time and space. Despite these difficulties, such data do yield a record which adds to the representative temporal sample as a level above some threshold reporting position. It therefore has potential for specific statistical analysis. An example of a reasonable temporal landslide

  15. Accuracy evaluation of optical distortion calibration by digital image correlation

    Science.gov (United States)

    Gao, Zeren; Zhang, Qingchuan; Su, Yong; Wu, Shangquan

    2017-11-01

    Due to its convenience of operation, the camera calibration algorithm, which is based on the plane template, is widely used in image measurement, computer vision and other fields. How to select a suitable distortion model is always a problem to be solved. Therefore, there is an urgent need for an experimental evaluation of the accuracy of camera distortion calibrations. This paper presents an experimental method for evaluating camera distortion calibration accuracy, which is easy to implement, has high precision, and is suitable for a variety of commonly used lens. First, we use the digital image correlation method to calculate the in-plane rigid body displacement field of an image displayed on a liquid crystal display before and after translation, as captured with a camera. Next, we use a calibration board to calibrate the camera to obtain calibration parameters which are used to correct calculation points of the image before and after deformation. The displacement field before and after correction is compared to analyze the distortion calibration results. Experiments were carried out to evaluate the performance of two commonly used industrial camera lenses for four commonly used distortion models.

  16. Calibration of a Stereo Radiation Detection Camera Using Planar Homography

    Directory of Open Access Journals (Sweden)

    Seung-Hae Baek

    2016-01-01

    Full Text Available This paper proposes a calibration technique of a stereo gamma detection camera. Calibration of the internal and external parameters of a stereo vision camera is a well-known research problem in the computer vision society. However, few or no stereo calibration has been investigated in the radiation measurement research. Since no visual information can be obtained from a stereo radiation camera, it is impossible to use a general stereo calibration algorithm directly. In this paper, we develop a hybrid-type stereo system which is equipped with both radiation and vision cameras. To calibrate the stereo radiation cameras, stereo images of a calibration pattern captured from the vision cameras are transformed in the view of the radiation cameras. The homography transformation is calibrated based on the geometric relationship between visual and radiation camera coordinates. The accuracy of the stereo parameters of the radiation camera is analyzed by distance measurements to both visual light and gamma sources. The experimental results show that the measurement error is about 3%.

  17. LONG-TERM CALIBRATION STABILITY OF A RADIO ASTRONOMICAL PHASED ARRAY FEED

    Energy Technology Data Exchange (ETDEWEB)

    Elmer, Michael; Jeffs, Brian D.; Warnick, Karl F. [Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT 84602 (United States)

    2013-01-01

    There are many challenges associated with the implementation of a phased array feed for radio astronomy applications. Among these is the need to have an adequate set of calibration measurements so that reliable beamformers can be computed. Changes in the operating environment and temporal gain drift in the electronics contribute to calibration drift, which affects the beamformer performance. We will show that calibration measurements are relatively stable over a 5 day period and may remain so for up to 70 days or longer. We have incorporated the use of a calibration update system that has the potential to refresh a set of old calibrators, specifically correcting for electronic gain drift. However, the long-term variations that are present with fresh, current calibrators are greater than the degradation due to using an old calibration set, suggesting that, at this time, there is not a need for sophisticated calibration update systems or algorithms.

  18. Viscometry for liquids calibration of viscometers

    CERN Document Server

    Gupta, S V

    2014-01-01

    This book is written for scientists involved in the calibration of viscometers. A detailed description for stepping up procedures to establish the viscosity scale and obtaining sets of master viscometers is given in the book. Uncertainty considerations for standard oils of known viscosity are presented. The modern viscometers based on principles of  tuning fork, ultrasonic, PZT, plate waves, Love waves, micro-cantilever and vibration of optical fiber are discussed to inspire the reader to further research and to generate improved versions. The primary standard for viscosity is pure water. Measurements of its viscosity with accuracy/uncertainty achieved are described. The principles of rotational and oscillation viscometers are explained to enhance the knowledge in calibration work. Devices used for specific materials and viscosity in non SI units are discussed with respect to the need to correlate viscosity values obtained by various devices. The description of commercial viscometers meets the needs of the u...

  19. SURFplus Model Calibration for PBX 9502

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-06

    The SURFplus reactive burn model is calibrated for the TATB based explosive PBX 9502 at three initial temperatures; hot (75 C), ambient (23 C) and cold (-55 C). The CJ state depends on the initial temperature due to the variation in the initial density and initial specific energy of the PBX reactants. For the reactants, a porosity model for full density TATB is used. This allows the initial PBX density to be set to its measured value even though the coeffcient of thermal expansion for the TATB and the PBX differ. The PBX products EOS is taken as independent of the initial PBX state. The initial temperature also affects the sensitivity to shock initiation. The model rate parameters are calibrated to Pop plot data, the failure diameter, the limiting detonation speed just above the failure diameters, and curvature effect data for small curvature.

  20. A novel PET camera calibration method

    International Nuclear Information System (INIS)

    Yerian, K.; Hartz, R.K.; Gaeta, J.M.; Marani, S.; Wong, W.H.; Bristow, D.; Mullani, N.A.

    1985-01-01

    Reconstructed time-of-flight PET images must be corrected for differences in the sensitivity of detector pairs, variations in the TOF gain between groups of detector pairs, and for shifts in the detector-pair timing windows. These calibration values are measured for each detector-pair coincidence line using a positron emitting ring source. The quality of the measured value for a detector pair depends on its statistics. To improve statistics, algorithms are developed which derive individual detector calibration values for efficiency, TOF offsets, and TOF fwhm from the raw detector-pair measurements. For the author's current TOFPET system there are 162,000 detector pairs which are reduced to 720 individual detector values. The data for individual detectors are subsequently recombined, improving the statistical quality of the resultant detector-pair values. In addition, storage requirements are significantly reduced by saving the individual detector values. These parameters are automatically evaluated on a routine basis and problem detectors reported for adjustment or replacement. Decomposing the detector-pair measurements into individual detector values significantly improves the calibration values used to correct camera artifacts in PET imaging

  1. Automatic Calibration of High Density Electric Muscle Stimulation

    DEFF Research Database (Denmark)

    Knibbe, Jarrod; Strohmeier, Paul; Boring, Sebastian

    2017-01-01

    . (2) EMS requires time consuming, expert calibration -- confining these interaction techniques to the lab. EMS arrays have been shown to increase stimulation resolution, but as calibration complexity increases exponentially as more electrodes are used, we require heuristics or automated procedures......Electric muscle stimulation (EMS) can enable mobile force feedback, support pedestrian navigation, or confer object affordances. To date, however, EMS is limited by two interlinked problems. (1) EMS is low resolution -- achieving only coarse movements and constraining opportunities for exploration...... for successful calibration. We explore the feasibility of using electromyography (EMG) to auto-calibrate high density EMS arrays. We determine regions of muscle activity during human-performed gestures, to inform stimulation patterns for EMS-performed gestures. We report on a study which shows that auto...

  2. CryoSat-2 SIRAL Calibration: Strategy, Application and Results

    Science.gov (United States)

    Parrinello, T.; Fornari, M.; Bouzinac, C.; Scagliola, M.; Tagliani, N.

    2012-04-01

    The main payload of CryoSat-2 is a Ku band pulsewidth limited radar altimeter, called SIRAL (Synthetic interferometric radar altimeter), that transmits pulses at a high pulse repetition frequency thus making the received echoes phase coherent and suitable for azimuth processing. This allows to reach an along track resolution of about 250 meters which is an important improvement over traditional pulse-width limited altimeters. Due to the fact that SIRAL is a phase coherent pulse-width limited radar altimeter, a proper calibration approach has been developed. In fact, not only the corrections for transfer function amplitude with respect to frequency, gain and instrument path delay have to be computed but it is also needed to provide corrections for transfer function phase with respect to frequency and AGC setting as well as the phase variation across bursts of pulses. As a consequence, SIRAL performs regularly four types of calibrations: (1) CAL1 in order to calibrate the internal path delay and peak power variation, (2) CAL2 in order to compensate the instrument transfer function, (3) CAL4 to calibrate the interferometer and (4) AutoCal, a specific sequence in order to calibrate the gain and phase difference for each AGC setting. Commissioning phase results (April-December 2010) revealed high stability of the instrument, which made possible to reduce the calibration frequency during Operations. Internal calibration data are processed on ground by the CryoSat-2 Instrument Processing Facility (IPF1) and then applied to the science data. In this poster we will describe as first the calibration strategy and then how the four different types of calibration are applied to science data. Moreover the calibration results over almost 2 years of mission will be presented, analyzing their temporal evolution in order to highlight the stability of the instrument over its life.

  3. Influence of rainfall observation network on model calibration and application

    Directory of Open Access Journals (Sweden)

    A. Bárdossy

    2008-01-01

    Full Text Available The objective in this study is to investigate the influence of the spatial resolution of the rainfall input on the model calibration and application. The analysis is carried out by varying the distribution of the raingauge network. A meso-scale catchment located in southwest Germany has been selected for this study. First, the semi-distributed HBV model is calibrated with the precipitation interpolated from the available observed rainfall of the different raingauge networks. An automatic calibration method based on the combinatorial optimization algorithm simulated annealing is applied. The performance of the hydrological model is analyzed as a function of the raingauge density. Secondly, the calibrated model is validated using interpolated precipitation from the same raingauge density used for the calibration as well as interpolated precipitation based on networks of reduced and increased raingauge density. Lastly, the effect of missing rainfall data is investigated by using a multiple linear regression approach for filling in the missing measurements. The model, calibrated with the complete set of observed data, is then run in the validation period using the above described precipitation field. The simulated hydrographs obtained in the above described three sets of experiments are analyzed through the comparisons of the computed Nash-Sutcliffe coefficient and several goodness-of-fit indexes. The results show that the model using different raingauge networks might need re-calibration of the model parameters, specifically model calibrated on relatively sparse precipitation information might perform well on dense precipitation information while model calibrated on dense precipitation information fails on sparse precipitation information. Also, the model calibrated with the complete set of observed precipitation and run with incomplete observed data associated with the data estimated using multiple linear regressions, at the locations treated as

  4. X-ray calibration qualities

    International Nuclear Information System (INIS)

    Burns, J.E.

    1998-01-01

    Since the recent publication of IAEA Technical Reports Series No. 374 ''Calibration of Dosimeters Used in Radiotheraphy'', there have been a number of queries about the origin of, and the rationale behind, the X-ray qualities recommended for calibration purposes. The simple answer is that these are the qualities derived at the UK National Physical Laboratory (NPL) in 1971 for calibration of therapy-level dosimeters and which are still in use for that purpose. As some SSDLs may have difficulties in adopting these exact combinations of kV and filtration. This paper discusses the basic ideas involved, and how to go about deriving a different series of qualities

  5. Preliminary assessment of the operating performance and calibration of rectilinear scanners and dose calibrators in Rio de Janeiro - Brazil

    International Nuclear Information System (INIS)

    Mendes, L.; Wegst, A.

    1983-01-01

    Thirty rectilinear scanners and ten dose calibrators were tested for a variety of operating conditions. The test for rectilinear scanners were based on image quality obtained with phantoms of the brain, liver (Williams phantom) and thyroid. The parameters investigated specifically for rectilinear scanners included those under direct control of the operator, such as proper setting of the focal distance, the velocity, the photopeak calibration, contrast correct collimator, line spacing, and background count. (E.G.) [pt

  6. Spectrophotometric calibration system for DECam

    Science.gov (United States)

    Rheault, J.-P.; DePoy, D. L.; Marshall, J. L.; Prochaska, T.; Allen, R.; Wise, J.; Martin, E.; Williams, P.

    2012-09-01

    We describe a spectrophotometric calibration system that is being implemented as part of the DES DECam project at the Blanco 4 meter at CTIO. Our calibration system uses a 1nm wide tunable source to measure the instrumental response function of the telescope optics and detector from 300nm up to 1100nm. This calibration will be performed regularly to monitor any change in the transmission function of the telescope during the 5 year survey. The system consists of a monochromator based tunable light source that provides illumination on a dome flat that is monitored by calibrated photodiodes that allow us to measure the telescope throughput as a function of wavelength. Our system has a peak output power of 2 mW, equivalent to a flux of approximately 800 photons/s/pixel on DECam.

  7. Recommended inorganic chemicals for calibration

    International Nuclear Information System (INIS)

    Moody, J.R.; Greenberg, R.R.; Pratt, K.W.; Rains, T.C.

    1988-01-01

    All analytical techniques depend on the use of calibration chemicals to relate analyte concentration to an instrumental parameter. A fundamental component in the preparation of calibration solutions is the weighing of a pure chemical or metal before preparing a solution standard. The analyst must be assured that the purity, stoichiometry, and assay of the chemical are known. These terms have different meanings, and each has an important influence. This report is intended to assist the analyst in the selection and use of chemical standards for instrumental calibration. Purity, stoichiometry, and preparation of solutions for different purposes are discussed, and a critical evaluation of the best materials available for each element is presented for use in preparing solutions or calibration standards. Information on the chemical form, source, purity, drying, and appropriate precautions is given. In some cases, multiple sources or chemical forms are available. Certain radioactive elements, the transuranic elements, and the noble gases are not considered

  8. Field calibration of cup anemometers

    Energy Technology Data Exchange (ETDEWEB)

    Kristensen, L.; Jensen, G.; Hansen, A.; Kirkegaard, P.

    2001-01-01

    An outdoor calibration facility for cup anemometers, where the signals from 10 anemometers of which at least one is a reference can be recorded simultaneously, has been established. The results are discussed with special emphasis on the statistical significance of the calibration expressions. It is concluded that the method has the advantage that many anemometers can be calibrated accurately with a minimum of work and cost. The obvious disadvantage is that the calibration of a set of anemometers may take more than one month in order to have wind speeds covering a sufficiently large magnitude range in a wind direction sector where we can be sure that the instruments are exposed to identical, simultaneous wind flows. Another main conclusion is that statistical uncertainty must be carefully evaluated since the individual 10 minute wind-speed averages are not statistically independent. (au)

  9. Calibration of radiation monitoring instruments

    International Nuclear Information System (INIS)

    1973-01-01

    Radiation protection is dependent on good radiation monitoring, and properly calibrated instruments are essential for this work. Simple procedures for periodically checking and recalibrating different kinds of radiation monitoring instruments are shown in this training film

  10. Calibration of "Babyline" RP instruments

    CERN Multimedia

    2015-01-01

      If you have old RP instrumentation of the “Babyline” type, as shown in the photo, please contact the Radiation Protection Group (Joffrey Germa, 73171) to have the instrument checked and calibrated. Thank you. Radiation Protection Group

  11. Calibration of radiation monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1974-12-31

    Radiation protection is dependent on good radiation monitoring, and properly calibrated instruments are essential for this work. Simple procedures for periodically checking and recalibrating different kinds of radiation monitoring instruments are shown in this training film

  12. Rotary mode system initial instrument calibration

    International Nuclear Information System (INIS)

    Johns, B.R.

    1994-01-01

    The attached report contains the vendor calibration procedures used for the initial instrument calibration of the rotary core sampling equipment. The procedures are from approved vendor information files

  13. Pressures Detector Calibration and Measurement

    CERN Document Server

    AUTHOR|(CDS)2156315

    2016-01-01

    This is report of my first and second projects (of 3) in NA61. I did data taking and analysis in order to do calibration of pressure detectors and verified it. I analyzed the data by ROOT software using the C ++ programming language. The first part of my project was determination of calibration factor of pressure sensors. Based on that result, I examined the relation between pressure drop, gas flow rate of in paper filter and its diameter.

  14. Development of SIR-C Ground Calibration Equipment

    Science.gov (United States)

    Freeman, A.; Azeem, M.; Haub, D.; Sarabandi, K.

    1993-01-01

    SIR-C/X-SAR is currently scheduled for launch in April 1994. SIR-C is an L-Band and C-Band, multi-polarization spaceborne SAR system developed by NASA/JPL. X- SAR is an X-Band SAR system developed by DARA/ASI. One of the problems involved in calibrating the SIR-C instrument is to make sure that the horizontal (H) and vertical (V) polarized beams are aligned in the azimuth direction, i.e.. that they are pointing in the same direction. This is important if the polarimetric performance specifications for the system are to be met. To solve this problem, we have designed and built a prototype of a low-cost ground receiver capable of recording received power from two antennas, one H-polarized, the other V-polarized. The two signals are mixed to audio then recorded on the left and right stereo channels of a standard audio cassette player. The audio cassette recording can then be played back directly into a Macintosh computer, where it is digitized. Analysis of.

  15. Evaluation of the energy dependence of ionization chambers pencil type calibrated beam tomography standards

    International Nuclear Information System (INIS)

    Fontes, Ladyjane Pereira; Potiens, Maria da Penha A.

    2015-01-01

    The Instrument Calibration Laboratory of IPEN (LCI - IPEN) performs calibrations of pencil-type ionization chambers (IC) used in measures of dosimetric survey on clinical systems of Computed Tomography (CT). Many users make mistakes when using a calibrated ionization chamber in their CT dosimetry systems. In this work a methodology for determination of factors of correction for quality (Kq) through the calibration curve that is specific for each ionization chamber was established. Furthermore, it was possible to demonstrate the energy dependence on an pencil-type Ionization Chamber(IC) calibrated at the LCI - IPEN. (author)

  16. Two laboratory methods for the calibration of GPS speed meters

    International Nuclear Information System (INIS)

    Bai, Yin; Sun, Qiao; Du, Lei; Yu, Mei; Bai, Jie

    2015-01-01

    The set-ups of two calibration systems are presented to investigate calibration methods of GPS speed meters. The GPS speed meter calibrated is a special type of high accuracy speed meter for vehicles which uses Doppler demodulation of GPS signals to calculate the measured speed of a moving target. Three experiments are performed: including simulated calibration, field-test signal replay calibration, and in-field test comparison with an optical speed meter. The experiments are conducted at specific speeds in the range of 40–180 km h −1 with the same GPS speed meter as the device under calibration. The evaluation of measurement results validates both methods for calibrating GPS speed meters. The relative deviations between the measurement results of the GPS-based high accuracy speed meter and those of the optical speed meter are analyzed, and the equivalent uncertainty of the comparison is evaluated. The comparison results justify the utilization of GPS speed meters as reference equipment if no fewer than seven satellites are available. This study contributes to the widespread use of GPS-based high accuracy speed meters as legal reference equipment in traffic speed metrology. (paper)

  17. Calibration through on-line monitoring of instruments channels

    International Nuclear Information System (INIS)

    James, R.W.

    1996-01-01

    Plant technical specifications require periodic calibration of instrument channels, and this has traditionally meant calibration at fixed time intervals for nearly all instruments. Experience has shown that unnecessarily frequent calibrations reduce channel availability and reliability, impact outage durations, and increase maintenance costs. An alternative approach to satisfying existing requirements for periodic calibration consists of on-line monitoring and quantitative comparison of instrument channels during operation to identify instrument degradation and failure. A Utility Working Group has been formed by EPRI to support the technical activities necessary to achieve generic NRC acceptance of on-line monitoring of redundant instrument channels as a basis for determining when to perform calibrations. A topical report proposing NRC acceptance of this approach was submitted in August 1995, and the Working Group is currently resolving NRC technical questions. This paper describes the proposed approach and the current status of the topical report with regard to NRC review. While these activities will not preclude utilities from continuing to use existing calibration approaches, successful acceptance of this performance-based approach will allow utilities to substantially reduce the number of calibrations which are performed. Concurrent benefits will include reduced I ampersand C impact on outage durations and improved sensitivity to instrument channel performance

  18. Calibration techniques and results for the Portsmouth Cf shuffler

    International Nuclear Information System (INIS)

    Gross, J.C.; Wines, K.M.

    1993-01-01

    As environmental concerns over radioactive waste disposal continue to rise, the importance of Californium shufflers as a versatile waste monitoring and segregation instrument also continue to increase. The extent to which different amounts and types of materials can be measured by the shuffler is directly related to the extent of its calibration. As shufflers become more common place and their waste management uses also rise, the importance of a wide ranging and thorough calibration becomes critical. This paper presents the techniques used at the Portsmouth Gaseous Diffusion Plant for calibrating the shuffler to detect levels of U-235 in radioactive waste. While the calibration techniques are similar to those used by Los Alamos, the standards that were used were constructed somewhat differently so that geometric effects are maximized. Also presented are shuffler transmission measurements that are used to determine the matrix type and the corresponding calibration. A discussion of the calibration data is given. This discussion includes specific aspects of the calibration such as overall range, high end limits, and poly shielding range and usefulness

  19. The coal. Its place in the world, the specifical problems of the european countries and more particularly the France; Le charbon. Sa place dans le monde, les problemes specifiques des pays d'Europe et tout particulierement de la France

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-12-15

    In a first part, the work group presents the available resources and studies the coal world market evolution. Then in a second time it discusses the european situation, and especially the french and german situation. The last part is devoted to the reconversion of the mines in France, the problems with the example of the coal basin of north of France. (A.L.B.)

  20. The KLOE online calibration system

    International Nuclear Information System (INIS)

    Pasqualucci, E.; Alexander, G.; Aloisio, A.

    2001-01-01

    Based on all the features of the KLOE online software, the online calibration system performs current calibration quality checking in real time and starts automatically new calibration procedures when needed. A calibration manager process controls the system, implementing the interface to the online system, receiving information from the run control and translating its state transitions to a separate state machine. It acts as a 'calibration run controller' and performs failure recovery when requested by a set of process checkers. The core of the system is a multi-threaded OO histogram server that receives histogramming commands by remote processes and operates on local ROOT histograms. A client library and C, fortran and C++ application interface libraries allow the user to connect and define his own histogram or read histograms owned by others using an book-like interface. Several calibration processes running in parallel in a distributed, multiplatform environment can fill the same histograms, allowing fast external information check. A monitor thread allow remote browsing for visual inspection. Pre-filtered data are read in non-privileged spy mode from the data acquisition system via the Kloe Integrated Dataflow. The main characteristics of the system are presented

  1. Simultaneous Calibration: A Joint Optimization Approach for Multiple Kinect and External Cameras.

    Science.gov (United States)

    Liao, Yajie; Sun, Ying; Li, Gongfa; Kong, Jianyi; Jiang, Guozhang; Jiang, Du; Cai, Haibin; Ju, Zhaojie; Yu, Hui; Liu, Honghai

    2017-06-24

    Camera calibration is a crucial problem in many applications, such as 3D reconstruction, structure from motion, object tracking and face alignment. Numerous methods have been proposed to solve the above problem with good performance in the last few decades. However, few methods are targeted at joint calibration of multi-sensors (more than four devices), which normally is a practical issue in the real-time systems. In this paper, we propose a novel method and a corresponding workflow framework to simultaneously calibrate relative poses of a Kinect and three external cameras. By optimizing the final cost function and adding corresponding weights to the external cameras in different locations, an effective joint calibration of multiple devices is constructed. Furthermore, the method is tested in a practical platform, and experiment results show that the proposed joint calibration method can achieve a satisfactory performance in a project real-time system and its accuracy is higher than the manufacturer's calibration.

  2. Matrix Factorisation-based Calibration For Air Quality Crowd-sensing

    Science.gov (United States)

    Dorffer, Clement; Puigt, Matthieu; Delmaire, Gilles; Roussel, Gilles; Rouvoy, Romain; Sagnier, Isabelle

    2017-04-01

    Internet of Things (IoT) is extending internet to physical objects and places. The internet-enabled objects are thus able to communicate with each other and with their users. One main interest of IoT is the ease of production of huge masses of data (Big Data) using distributed networks of connected objects, thus making possible a fine-grained yet accurate analysis of physical phenomena. Mobile crowdsensing is a way to collect data using IoT. It basically consists of acquiring geolocalized data from the sensors (from or connected to the mobile devices, e.g., smartphones) of a crowd of volunteers. The sensed data are then collectively shared using wireless connection—such as GSM or WiFi—and stored on a dedicated server to be processed. One major application of mobile crowdsensing is environment monitoring. Indeed, with the proliferation of miniaturized yet sensitive sensors on one hand and, on the other hand, of low-cost microcontrollers/single-card PCs, it is easy to extend the sensing abilities of smartphones. Alongside the conventional, regulated, bulky and expensive instruments used in authoritative air quality stations, it is then possible to create a large-scale mobile sensor network providing insightful information about air quality. In particular, the finer spatial sampling rate due to such a dense network should allow air quality models to take into account local effects such as street canyons. However, one key issue with low-cost air quality sensors is the lack of trust in the sensed data. In most crowdsensing scenarios, the sensors (i) cannot be calibrated in a laboratory before or during their deployment and (ii) might be sparsely or continuously faulty (thus providing outliers in the data). Such issues should be automatically handled from the sensor readings. Indeed, due to the masses of generated data, solving the above issues cannot be performed by experts but requires specific data processing techniques. In this work, we assume that some mobile

  3. Optical model and calibration of a sun tracker

    International Nuclear Information System (INIS)

    Volkov, Sergei N.; Samokhvalov, Ignatii V.; Cheong, Hai Du; Kim, Dukhyeon

    2016-01-01

    Sun trackers are widely used to investigate scattering and absorption of solar radiation in the Earth's atmosphere. We present a method for optimization of the optical altazimuth sun tracker model with output radiation direction aligned with the axis of a stationary spectrometer. The method solves the problem of stability loss in tracker pointing at the Sun near the zenith. An optimal method for tracker calibration at the measurement site is proposed in the present work. A method of moving calibration is suggested for mobile applications in the presence of large temperature differences and errors in the alignment of the optical system of the tracker. - Highlights: • We present an optimal optical sun tracker model for atmospheric spectroscopy. • The problem of loss of stability of tracker pointing at the Sun has been solved. • We propose an optimal method for tracker calibration at a measurement site. • Test results demonstrate the efficiency of the proposed optimization methods.

  4. Risk and associated risk factors of hospitalization for specific health problems over time in childhood cancer survivors : a medical record linkage study

    NARCIS (Netherlands)

    Font-Gonzalez, Anna; Feijen, Elizabeth Lieke A.M.; Geskus, Ronald B; Dijkgraaf, Marcel G. W.; van der Pal, Helena J.H.; Heinen, Richard C.; Jaspers, Monique W; van Leeuwen, Flora E.; Reitsma, J. B.Johannes; Caron, Hubert N; Sieswerda, Elske; Kremer, Leontien C M

    2017-01-01

    Childhood cancer survivors (CCS) experience higher hospitalization rates compared to the general population for neoplasms, circulatory diseases, endocrine/nutritional/metabolic diseases and eye disorders. We studied trends in hospitalization rates and associated patient and treatment-specific risk

  5. The Geostationary Lightning Mapper: Its Performance and Calibration

    Science.gov (United States)

    Christian, H. J., Jr.

    2015-12-01

    The Geostationary Lightning Mapper (GLM) has been developed to be an operational instrument on the GOES-R series of spacecraft. The GLM is a unique instrument, unlike other meteorological instruments, both in how it operates and in the information content that it provides. Instrumentally, it is an event detector, rather than an imager. While processing almost a billion pixels per second with 14 bits of resolution, the event detection process reduces the required telemetry bandwidth by almost 105, thus keeping the telemetry requirements modest and enabling efficient ground processing that leads to rapid data distribution to operational users. The GLM was designed to detect about 90 percent of the total lightning flashes within its almost hemispherical field of view. Based on laboratory calibration, we expect the on-orbit detection efficiency to be closer to 85%, making it the highest performing, large area coverage total lightning detector. It has a number of unique design features that will enable it have near uniform special resolution over most of its field of view and to operate with minimal impact on performance during solar eclipses. The GLM has no dedicated on-orbit calibration system, thus the ground-based calibration provides the bases for the predicted radiometric performance. A number of problems were encountered during the calibration of Flight Model 1. The issues arouse from GLM design features including its wide field of view, fast lens, the narrow-band interference filters located in both object and collimated space and the fact that the GLM is inherently a event detector yet the calibration procedures required both calibration of images and events. The GLM calibration techniques were based on those developed for the Lightning Imaging Sensor calibration, but there are enough differences between the sensors that the initial GLM calibration suggested that it is significantly more sensitive than its design parameters. The calibration discrepancies have

  6. IOT Overview: Calibrations of the VLTI Instruments (MIDI and AMBER)

    Science.gov (United States)

    Morel, S.; Rantakyrö, F.; Rivinius, T.; Stefl, S.; Hummel, C.; Brillant, S.; Schöller, M.; Percheron, I.; Wittkowski, M.; Richichi, A.; Ballester, P.

    We present here a short review of the calibration processes that are currently applied to the instruments AMBER and MIDI of the VLTI (Very Large Telescope Interferometer) at Paranal. We first introduce the general principles to calibrate the raw data (the "visibilities") that have been measured by long-baseline optical interferometry. Then, we focus on the specific case of the scientific operation of the VLTI instruments. We explain the criteria that have been used to select calibrator stars for the observations with the VLTI instruments, as well as the routine internal calibration techniques. Among these techniques, the "P2VM" (Pixel-to-Visibility Matrix) in the case of AMBER is explained. Also, the daily monitoring of AMBER and MIDI, that has recently been implemented, is shortly introduced.

  7. Calibration of a compact magnetic proton recoil neutron spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Jianfu, E-mail: zhang_jianfu@163.com [School of Nuclear Science and Technology, Xi' an Jiaotong University, Xi' an 710049 (China); Northwest Institute of Nuclear Technology, Xi' an 710024 (China); Ouyang, Xiaoping; Zhang, Xianpeng [School of Nuclear Science and Technology, Xi' an Jiaotong University, Xi' an 710049 (China); Northwest Institute of Nuclear Technology, Xi' an 710024 (China); Ruan, Jinlu [Northwest Institute of Nuclear Technology, Xi' an 710024 (China); Zhang, Guoguang [Applied Institute of Nuclear Technology, China Institute of Atomic Energy, Beijing 102413 (China); Zhang, Xiaodong [Northwest Institute of Nuclear Technology, Xi' an 710024 (China); Qiu, Suizheng, E-mail: szqiu@mail.xjtu.edu.cn [School of Nuclear Science and Technology, Xi' an Jiaotong University, Xi' an 710049 (China); Chen, Liang; Liu, Jinliang; Song, Jiwen; Liu, Linyue; Yang, Shaohua [Northwest Institute of Nuclear Technology, Xi' an 710024 (China)

    2016-04-21

    Magnetic proton recoil (MPR) neutron spectrometer is considered as a powerful instrument to measure deuterium–tritium (DT) neutron spectrum, as it is currently used in inertial confinement fusion facilities and large Tokamak devices. The energy resolution (ER) and neutron detection efficiency (NDE) are the two most important parameters to characterize a neutron spectrometer. In this work, the ER calibration for the MPR spectrometer was performed by using the HI-13 tandem accelerator at China Institute of Atomic Energy (CIAE), and the NDE calibration was performed by using the neutron generator at CIAE. The specific calibration techniques used in this work and the associated accuracies were discussed in details in this paper. The calibration results were presented along with Monte Carlo simulation results.

  8. The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Habte, Aron; Sengupta, Manajit; Andreas, Afshin; Reda, Ibrahim; Robinson, Justin

    2016-07-01

    Accurate solar radiation data sets are critical to reducing the expenses associated with mitigating performance risk for solar energy conversion systems, and they help utility planners and grid system operators understand the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of calibration methodologies and the resulting calibration responsivities provided by radiometric calibration service providers such as the National Renewable Energy Laboratory (NREL) and manufacturers of radiometers. Some of these radiometers are calibrated indoors, and some are calibrated outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The reference radiometer calibrations are traceable to the World Radiometric Reference. These different methods of calibration demonstrated 1% to 2% differences in solar irradiance measurement. Analyzing these values will ultimately assist in determining the uncertainties of the radiometer data and will assist in developing consensus on a standard for calibration.

  9. Some problems in the calibration of the acoustic emission sensors

    International Nuclear Information System (INIS)

    Dingwall, P.F.; Stone, D.E.W.

    1976-01-01

    The frequency response of transducers (continuous wave excitation, pulse excitation) and the sensitivity or amplitude of the response to a standard stimulus (absolute sensitivity, relative sensitivity) are studied

  10. Early Evaluation of the VIIRS Calibration, Cloud Mask and Surface Reflectance Earth Data Records

    Science.gov (United States)

    Vermote, Eric; Justice, Chris; Csiszar, Ivan

    2014-01-01

    Surface reflectance is one of the key products fromVIIRS and as withMODIS, is used in developing several higherorder land products. The VIIRS Surface Reflectance (SR) Intermediate Product (IP) is based on the heritageMODIS Collection 5 product (Vermote, El Saleous, & Justice, 2002). The quality and character of surface reflectance depend on the accuracy of the VIIRS Cloud Mask (VCM), the aerosol algorithms and the adequate calibration of the sensor. The focus of this paper is the early evaluation of the VIIRS SR product in the context of the maturity of the operational processing system, the Interface Data Processing System (IDPS). After a brief introduction, the paper presents the calibration performance and the role of the surface reflectance in calibration monitoring. The analysis of the performance of the cloud mask with a focus on vegetation monitoring (no snow conditions) shows typical problems over bright surfaces and high elevation sites. Also discussed is the performance of the aerosol input used in the atmospheric correction and in particular the artifacts generated by the use of the Navy Aerosol Analysis and Prediction System. Early quantitative results of the performance of the SR product over the AERONET sites showthatwith the fewadjustments recommended, the accuracy iswithin the threshold specifications. The analysis of the adequacy of the SR product (Land PEATE adjusted version) in applications of societal benefits is then presented. We conclude with a set of recommendations to ensure consistency and continuity of the JPSS mission with the MODIS Land Climate Data Record.

  11. The Monitoring and Calibration Web Systems for the ATLAS Tile Calorimeter Data Quality Analysis

    International Nuclear Information System (INIS)

    Sivolella, A; Maidantchik, C; Ferreira, F

    2012-01-01

    The Tile Calorimeter (TileCal) is one of the ATLAS sub-detectors. The read-out is performed by about 10,000 PhotoMultiplier Tubes (PMTs). The signal of each PMT is digitized by an electronic channel. The Monitoring and Calibration Web System (MCWS) supports the data quality analysis of the electronic channels. This application was developed to assess the detector status and verify its performance. It can provide to the user the list of TileCal known problematic channels, that is stored in the ATLAS condition database (COOL DB). The bad channels list guides the data quality validator in identifying new problematic channels and is used in data reconstruction and the system allows to update the channels list directly in the COOL database. MCWS can generate summary results, such as eta-phi plots and comparative tables of the masked channels percentage. Regularly, during the LHC (Large Hadron Collider) shutdown a maintenance of the detector equipments is performed. When a channel is repaired, its calibration constants stored in the COOL database have to be updated. Additionally MCWS system manages the update of these calibration constants values in the COOL database. The MCWS has been used by the Tile community since 2008, during the commissioning phase, and was upgraded to comply with ATLAS operation specifications. Among its future developments, it is foreseen an integration of MCWS with the TileCal control Web system (DCS) in order to identify high voltage problems automatically.

  12. Multivariate calibration with least-squares support vector machines.

    NARCIS (Netherlands)

    Thissen, U.M.J.; Ustun, B.; Melssen, W.J.; Buydens, L.M.C.

    2004-01-01

    This paper proposes the use of least-squares support vector machines (LS-SVMs) as a relatively new nonlinear multivariate calibration method, capable of dealing with ill-posed problems. LS-SVMs are an extension of "traditional" SVMs that have been introduced recently in the field of chemistry and

  13. DOE Radiological Calibrations Intercomparison Program: Results of fiscal year 1987

    International Nuclear Information System (INIS)

    Cummings, F.M.; McDonald, J.C.

    1988-06-01

    This report presents the FY 1987 results of the radiological calibrations intercomparison program. The intercomparison operation is discussed, and the equipment is described, particularly the instrument set, the beta source set, and relevant calculations. Solutions to problems and improvements in the program are suggested, and conclusions are then introduced. 9 refs., 3 figs., 8 tabs

  14. Radioactive sources for ATLAS hadron tile calorimeter calibration

    International Nuclear Information System (INIS)

    Budagov, Yu.; Cavalli-Sforza, M.; Ivanyushenkov, Yu.

    1997-01-01

    The main requirements for radioactive sources applied in the TileCal calibration systems are formulated; technology of the sources production developed in the Laboratory of Nuclear Problems, JINR is described. Design and characteristics of the prototype sources manufactured in Dubna and tested on ATLAS TileCal module 0 are presented

  15. Magnetometer and Gyroscope Calibration Method with Level Rotation

    Directory of Open Access Journals (Sweden)

    Zongkai Wu

    2018-03-01

    Full Text Available Micro electro mechanical system (MEMS gyroscopes and magnetometers are usually integrated into a sensor module or chip and widely used in a variety of applications. In existing integrated gyroscope and magnetometer calibration methods, rotation in all possible orientations is a necessary condition for a good calibration result. However, rotation around two or more axes is difficult to attain, as it is limited by the range of movement of vehicles such as cars, ships, or planes. To solve this problem, this paper proposes an integrated magnetometer and gyroscope calibration method with level rotation. The proposed method presents a redefined magnetometer output model using level attitude. New gyroscope and magnetometer calibration models are then deduced. In addition, a simplified cubature Kalman filter (CKF is established to estimate calibration parameters. This method possesses important value for application in actual systems, as it only needs level rotation for real-time calibration of gyroscopes and magnetometers. Theoretical analysis and test results verify the validity and feasibility of this method.

  16. Remote calibration system of a smart electrical energy meter

    Directory of Open Access Journals (Sweden)

    Zakariae Jebroni

    2017-12-01

    Full Text Available The need to control the power grid in real time has opened a new field of research, today researchers are trying to design electrical meters that are completely remote controlled, to create an advanced metering infrastructure. One of the most important processes in the field of measurement is the calibration of measuring instruments. The calibration process of the electrical meters was performed at laboratories. However, the new directives, now, require a regular test of accuracy. Nevertheless, moving each time on site to check the accuracy of a meter can be annoying. To solve this problem our contribution is to propose a new structure of a smart meter that integrates a calibration card, so that, this process is carried out remotely. To be able to calibrate the meter or test its accuracy, we have included an AC-AC converter powered by the electrical grid and that provides a stable voltage independent of the electrical grid in term of frequency and amplitude. The output voltage of the converter is used as the reference signal during calibration or accuracy testing. In this paper, we will present the structure of the calibration card, the study and dimensioning of the converter, as well as the control technique used to eliminate variations of the input voltage. At the end, we will present the results of simulations and experiments.

  17. The Chandra Source Catalog 2.0: Calibrations

    Science.gov (United States)

    Graessle, Dale E.; Evans, Ian N.; Rots, Arnold H.; Allen, Christopher E.; Anderson, Craig S.; Budynkiewicz, Jamie A.; Burke, Douglas; Chen, Judy C.; Civano, Francesca Maria; D'Abrusco, Raffaele; Doe, Stephen M.; Evans, Janet D.; Fabbiano, Giuseppina; Gibbs, Danny G., II; Glotfelty, Kenny J.; Grier, John D.; Hain, Roger; Hall, Diane M.; Harbo, Peter N.; Houck, John C.; Lauer, Jennifer L.; Laurino, Omar; Lee, Nicholas P.; Martínez-Galarza, Juan Rafael; McCollough, Michael L.; McDowell, Jonathan C.; Miller, Joseph; McLaughlin, Warren; Morgan, Douglas L.; Mossman, Amy E.; Nguyen, Dan T.; Nichols, Joy S.; Nowak, Michael A.; Paxson, Charles; Plummer, David A.; Primini, Francis Anthony; Siemiginowska, Aneta; Sundheim, Beth A.; Tibbetts, Michael; Van Stone, David W.; Zografou, Panagoula

    2018-01-01

    Among the many enhancements implemented for the release of Chandra Source Catalog (CSC) 2.0 are improvements in the processing calibration database (CalDB). We have included a thorough overhaul of the CalDB software used in the processing. The software system upgrade, called "CalDB version 4," allows for a more rational and consistent specification of flight configurations and calibration boundary conditions. Numerous improvements in the specific calibrations applied have also been added. Chandra's radiometric and detector response calibrations vary considerably with time, detector operating temperature, and position on the detector. The CalDB has been enhanced to provide the best calibrations possible to each observation over the fifteen-year period included in CSC 2.0. Calibration updates include an improved ACIS contamination model, as well as updated time-varying gain (i.e., photon energy) and quantum efficiency maps for ACIS and HRC-I. Additionally, improved corrections for the ACIS quantum efficiency losses due to CCD charge transfer inefficiency (CTI) have been added for each of the ten ACIS detectors. These CTI corrections are now time and temperature-dependent, allowing ACIS to maintain a 0.3% energy calibration accuracy over the 0.5-7.0 keV range for any ACIS source in the catalog. Radiometric calibration (effective area) accuracy is estimated at ~4% over that range. We include a few examples where improvements in the Chandra CalDB allow for improved data reduction and modeling for the new CSC.This work has been supported by NASA under contract NAS 8-03060 to the Smithsonian Astrophysical Observatory for operation of the Chandra X-ray Center.

  18. Safety enhancement through calibration and maintenance

    International Nuclear Information System (INIS)

    Mohammad Ali Khalid; Taiman Kadni

    2000-01-01

    Although radiation causes an alarming effect to living organism, it has been accepted for diagnostic and therapy in medicine as well as quality control and test method in industry. Due to the benefit gained, public at large is willing to accept the risk on condition that proper protection and safety standard is implemented and practised. Instrument plays a very important role not only in generation radiation but also measuring it. Therefore to ensure safety it is fair to say that all instrument must be calibrated to a certain standard and maintained to operate to its design specifications from time to time. (author)

  19. The role of context in preschool learning: a multilevel examination of the contribution of context-specific problem behaviors and classroom process quality to low-income children's approaches to learning.

    Science.gov (United States)

    Domínguez, Ximena; Vitiello, Virginia E; Fuccillo, Janna M; Greenfield, Daryl B; Bulotsky-Shearer, Rebecca J

    2011-04-01

    Research suggests that promoting adaptive approaches to learning early in childhood may help close the gap between advantaged and disadvantaged children. Recent research has identified specific child-level and classroom-level variables that are significantly associated with preschoolers' approaches to learning. However, further research is needed to understand the interactive effects of these variables and determine whether classroom-level variables buffer the detrimental effects of child-level risk variables. Using a largely urban and minority sample (N=275) of preschool children, the present study examined the additive and interactive effects of children's context-specific problem behaviors and classroom process quality dimensions on children's approaches to learning. Teachers rated children's problem behavior and approaches to learning and independent assessors conducted classroom observations to assess process quality. Problem behaviors in structured learning situations and in peer and teacher interactions were found to negatively predict variance in approaches to learning. Classroom process quality domains did not independently predict variance in approaches to learning. Nonetheless, classroom process quality played an important role in these associations; high emotional support buffered the detrimental effects of problem behavior, whereas high instructional support exacerbated them. The findings of this study have important implications for classroom practices aimed at helping children who exhibit problem behaviors. Copyright © 2010 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  20. The role of a certified calibration laboratory in a station's measuring and test equipment calibration, repair, and documentation program

    International Nuclear Information System (INIS)

    Ebenstreit, K.; MacIntosh, N.

    1995-01-01

    This paper outlines the role of a Certified Calibration Laboratory in- ensuring that the requirements of Measuring and Test Equipment calibration, identification, and traceability are met and documented. The Nuclear environment is one which is subject to influences from numerous 'quality agents'. One of the fields which comes under the scrutiny of the quality agents is that of equipment calibration and repair (both field components and M and TE). There is a responsibility to produce a superior product for the Ontario Consumer. The maintenance and calibration of Station Systems and their components have a direct impact on this output. The Measuring and Test Equipment element in each of these needs can be addressed by having a defined group of Maintenance Staff to execute a Measuring and Test Equipment Program which meets specific parameters. (author)

  1. FTIR Calibration Methods and Issues

    Science.gov (United States)

    Perron, Gaetan

    Over the past 10 years, several space-borne FTIR missions were launched for atmospheric research, environmental monitoring and meteorology. One can think of the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) launched by the European Space Agency, the Atmospheric Chemistry Experiment (ACE) launched by the Canadian Space Agency, the Tropospheric Emission Spectrometer (TES) launched by NASA and the Infrared Atmospheric Sounding Interferometer (IASI) launched by Eumetsat in Europe. Others are near to be launched, namely the Cross-track Infrared Sounder (CrIS) from the Integrated Program Of- fice in the United States and the Thermal And Near infrared Sensor for carbon Observation (TANSO) from the Japan Aerospace Exploration Agency. Moreover, several missions under definition foresee the use of this technology as sensor, e.g. Meteosat Third Generation (MTG), Eumetsat Polar System (EPS) and the Premier mission, one of the six candidates of the next ESA Earth Explorer Core Mission. In order to produce good quality products, calibration is essential. Calibrated data is the output of three main sub-systems that are tightly coupled: the instrument, the calibration targets and the level 1B processor. Calibration requirements must be carefully defined and propagated to each sub-system. Often, they are carried out by different parties which add to the complexity. Under budget and schedule pressure, some aspects are sometimes neglected and jeopardized final quality. For space-borne FTIR, level 1B outputs are spectra that are radiometrically, spectrally calibrated and geolocated. Radiometric calibration means to assign an intensity value in units to the y-axis. Spectral calibration means to assign to the x-axis the proper frequency value in units. Finally, geolocated means to assign a target position over the earth geoid i.e. longitude, latitude and altitude. This paper will present calibration methods and issues related to space-borne FTIR missions, e.g. two

  2. Simulation and Evaluation of ECT Signals From MRPC Probe in Combo Calibration Standard Tube Using Electromagnetic Numerical Analysis

    International Nuclear Information System (INIS)

    Yoo, Joo Young; Song, Sung Jin; Jung, Hee Jun; Kong, Young Bae

    2006-01-01

    Signals captured from a Combo calibration standard tube play a crucial role in the evaluation of motorized rotating pancake coil (MRPC) probe signals from steam generator (SG) tubes in nuclear power plants (NPPs). Therefore, the Combo tube signals should be consistent and accurate. However, MRPC probe signals are very easily affected by various factors around the tubes so that they can be distorted in their amplitudes and phase angles which are the values specifically used in the evaluation. To overcome this problem, in this study, we explored possibility of simulation to be used as a practical calibration tool far the evaluation of real field signals. For this purpose, we investigated the characteristics of a MRPC probe and a Combo tube. And then using commercial software (VIC-3D) we simulated a set of calibration signals and compared to the experimental signals. From this comparison, we verified the accuracy of the simulated signals. Finally, we evaluated two defects using the simulated Combo tube signals, and the results were compared with those obtained using the actual field calibration signals

  3. Calibration laboratories as a regional repair center: consolidate or collocate

    OpenAIRE

    Mitchell, Marquita A; Pasch, John E.

    1996-01-01

    The purpose of this thesis is to examine the integration of AIMDs Miramar and North Island, and NADEP North Island calibration laboratories. The expected benefits and weaknesses or problems resulting from integration are examined. The benefits analyzed include those in the areas of manpower, training, standards reduction, inventory reduction, streamlining facilities, and increased productivity. The problems analyzed include increased transportation costs, facilities modification costs, reduce...

  4. "Mastery Learning" Como Metodo Psicoeducativo para Ninos con Problemas Especificos de Aprendizaje. ("Mastery Learning" as a Psychoeducational Method for Children with Specific Learning Problems.)

    Science.gov (United States)

    Coya, Liliam de Barbosa; Perez-Coffie, Jorge

    1982-01-01

    "Mastery Learning" was compared with the "conventional" method of teaching reading skills to Puerto Rican children with specific learning disabilities. The "Mastery Learning" group showed significant gains in the cognitive and affective domains. Results suggested Mastery Learning is a more effective method of teaching…

  5. The short-term effects of a body awareness program : better self-management of health problems for individuals with chronic a-specific psychosomatic symptoms

    NARCIS (Netherlands)

    Landsman-Dijkstra, Jeanet J. A.; van Wijck, R; Groothoff, JW; Rispens, P

    A three-day residential Body Awareness Program (BAP) was developed to teach people with Chronic A-specific Psychosomatic Symptoms (CAPS) to react adequately to disturbances of the balance between a daily workload and the capacity to deal with it. The short-term effects of the program for people with

  6. The short-term effects of a body awareness program : better self-management of health problems for individuals with chronic a-specific psychosomatic symptoms

    NARCIS (Netherlands)

    Landsman-Dijkstra, Jeanet J. A.; van Wijck, R; Groothoff, JW; Rispens, P

    2004-01-01

    A three-day residential Body Awareness Program (BAP) was developed to teach people with Chronic A-specific Psychosomatic Symptoms (CAPS) to react adequately to disturbances of the balance between a daily workload and the capacity to deal with it. The short-term effects of the program for people with

  7. Automatic calibration of gamma spectrometers

    International Nuclear Information System (INIS)

    Tluchor, D.; Jiranek, V.

    1989-01-01

    The principle is described of energy calibration of the spectrometric path based on the measurement of the standard of one radionuclide or a set of them. The entire computer-aided process is divided into three main steps, viz.: the insertion of the calibration standard by the operator; the start of the calibration program; energy calibration by the computer. The program was selected such that the spectrum identification should not depend on adjustment of the digital or analog elements of the gamma spectrometric measuring path. The ECL program is described for automatic energy calibration as is its control, the organization of data file ECL.DAT and the necessary hardware support. The computer-multichannel analyzer communication was provided using an interface pair of Canberra 8673V and Canberra 8573 operating in the RS-422 standard. All subroutines for communication with the multichannel analyzer were written in MACRO 11 while the main program and the other subroutines were written in FORTRAN-77. (E.J.). 1 tab., 4 refs

  8. Calibration of the SNO+ experiment

    Science.gov (United States)

    Maneira, J.; Falk, E.; Leming, E.; Peeters, S.; SNO+ Collaboration.

    2017-09-01

    The main goal of the SNO+ experiment is to perform a low-background and high-isotope-mass search for neutrinoless double-beta decay, employing 780 tonnes of liquid scintillator loaded with tellurium, in its initial phase at 0.5% by mass for a total mass of 1330 kg of 130Te. The SNO+ physics program includes also measurements of geo- and reactor neutrinos, supernova and solar neutrinos. Calibrations are an essential component of the SNO+ data-taking and analysis plan. The achievement of the physics goals requires both an extensive and regular calibration. This serves several goals: the measurement of several detector parameters, the validation of the simulation model and the constraint of systematic uncertainties on the reconstruction and particle identification algorithms. SNO+ faces stringent radiopurity requirements which, in turn, largely determine the materials selection, sealing and overall design of both the sources and deployment systems. In fact, to avoid frequent access to the inner volume of the detector, several permanent optical calibration systems have been developed and installed outside that volume. At the same time, the calibration source internal deployment system was re-designed as a fully sealed system, with more stringent material selection, but following the same working principle as the system used in SNO. This poster described the overall SNO+ calibration strategy, discussed the several new and innovative sources, both optical and radioactive, and covered the developments on source deployment systems.

  9. Calibration strategies for the Cherenkov Telescope Array

    NARCIS (Netherlands)

    Gaug, M.; Berge, D.; Daniel, M.; Doro, M.; Förster, A.; Hofmann, W.; Maccarone, M.C.; Parsons, D.; de los Reyes Lopez, R.; van Eldik, C.

    2014-01-01

    The Central Calibration Facilities workpackage of the Cherenkov Telescope Array (CTA) observatory for very high energy gamma ray astronomy defines the overall calibration strategy of the array, develops dedicated hardware and software for the overall array calibration and coordinates the calibration

  10. A General Discussion of Problems Related to the Determination of Concrete Armour Unit Stresses Including Specific Results related to Static and Dynamic Stresses in Dolosse

    DEFF Research Database (Denmark)

    Burcharth, H. F.; Liu, Zhou

    1989-01-01

    Recent breakwater failures revealed the shortcomings of the traditional design procedures for concrete armour units. This paper deals with one of them, which can be expressed as the "lack of balance between the hydraulic stability of the armour layer and the mechanical strength or integrity...... of the units". This problem is related mainly to the slender types of armour units. The paper discusses the various types of loads, and the practical determination of the wave and gravity induced loads and stresses, especially the model test technique and its restrictions. Examples related to Dolosse...

  11. Combining engineering and data-driven approaches: Development of a generic fire risk model facilitating calibration

    DEFF Research Database (Denmark)

    De Sanctis, G.; Fischer, K.; Kohler, J.

    2014-01-01

    Fire risk models support decision making for engineering problems under the consistent consideration of the associated uncertainties. Empirical approaches can be used for cost-benefit studies when enough data about the decision problem are available. But often the empirical approaches...... a generic risk model that is calibrated to observed fire loss data. Generic risk models assess the risk of buildings based on specific risk indicators and support risk assessment at a portfolio level. After an introduction to the principles of generic risk assessment, the focus of the present paper...... are not detailed enough. Engineering risk models, on the other hand, may be detailed but typically involve assumptions that may result in a biased risk assessment and make a cost-benefit study problematic. In two related papers it is shown how engineering and data-driven modeling can be combined by developing...

  12. Calibration of region-specific gates equation for LRFD.

    Science.gov (United States)

    2014-02-01

    The objectives of this research are to recalibrate the FHWA-modi ed Gates equation : and update the associated LRFD resistance factor for pile types and local soil conditions : encountered in Louisiana. This research is consistent with FHWA recomm...

  13. Calibration pipeline for VIR data

    Science.gov (United States)

    Carraro, F.; Fonte, S.; Coradini, A.; Filacchione, G.; de Sanctis, M. C.; Ammannito, E.; Capria, M. T.; Cartacci, M.; Noschese, R.; Tosi, F.; Capaccioni, F.

    2011-10-01

    During the second quarter of 2011 VIR-MS (VIS and IR Mapping Spectrometer) [1] aboard Dawn mission [2] has approached Vesta in order to start a long period of acquisitions that will end at the beginning of 2012. Data acquired by each instrument always require a calibration process in order to remove all the instrument effects that could affect the scientific evaluations and analysis. VIR-MS instrument team has realized a calibration pipeline which has the goal of producing calibrated (1b level) data starting from the raw (1a level) ones. The other goal of the tool has been the check of the goodness of acquired data by means of the evaluation of a series of minimum requisites of each data file, such as the percentage of the saturated pixels, the presence of spikes or the mean S/N ratio of each qube.

  14. Radiation protection dosimetry and calibrations

    International Nuclear Information System (INIS)

    Verhavere, Ph.

    2007-01-01

    At the SCK-CEN different specialised services are delivered for a whole range of external and internal customers in the radiation protection area. For the expertise group of radiation protection dosimetry and calibrations, these services are organized in four different laboratories: dosimetry, anthropogammametry, nuclear calibrations and non-nuclear calibrations. The services are given by a dedicated technical staff who has experience in the handling of routine and specialised cases. The scientific research that is performed by the expertise group makes sure that state-of-the-art techniques are being used, and that constant improvements and developments are implemented. Quality Assurance is an important aspect for the different services, and accreditation according national and international standards is achieved for all laboratories

  15. Dealing with the problem of non-specific in situ mRNA hybridization signals associated with plant tissues undergoing programmed cell death

    Directory of Open Access Journals (Sweden)

    Jokela Anne

    2010-02-01

    Full Text Available Abstract Background In situ hybridization is a general molecular method typically used for the localization of mRNA transcripts in plants. The method provides a valuable tool to unravel the connection between gene expression and anatomy, especially in species such as pines which show large genome size and shortage of sequence information. Results In the present study, expression of the catalase gene (CAT related to the scavenging of reactive oxygen species (ROS and the polyamine metabolism related genes, diamine oxidase (DAO and arginine decarboxylase (ADC, were localized in developing Scots pine (Pinus sylvestris L. seeds. In addition to specific signals from target mRNAs, the probes continually hybridized non-specifically in the embryo surrounding region (ESR of the megagametophyte tissue, in the remnants of the degenerated suspensors as well as in the cells of the nucellar layers, i.e. tissues exposed to cell death processes and extensive nucleic acid fragmentation during Scots pine seed development. Conclusions In plants, cell death is an integral part of both development and defence, and hence it is a common phenomenon in all stages of the life cycle. Our results suggest that extensive nucleic acid fragmentation during cell death processes can be a considerable source of non-specific signals in traditional in situ mRNA hybridization. Thus, the visualization of potential nucleic acid fragmentation simultaneously with the in situ mRNA hybridization assay may be necessary to ensure the correct interpretation of the signals in the case of non-specific hybridization of probes in plant tissues.

  16. Problems connected with the production of highly specific antisera against prostaglandin E2 (PGE2) and prostaglandin A2 (PGA2) for radioimmunoassay

    International Nuclear Information System (INIS)

    Kopp, H.G.; Vetter, W.; Siegenthaler, W.

    1978-01-01

    To obtain sensitive and specific antisera against PGE 2 and PGA 2 these substances were coupled to thyroglobulin (Tg). Coupling reactions were performed by using either a hydroxy-succinimide-ester as intermediate step leading to a complex carrying 170mol PGE 2 per mol Tg (''PGE 2 -OSU-Tg'') and 240mol PGA 2 per mol Tg (''PGA 2 -OSU-Tg''), or N, N'-carbonyl-diimidazole resulting in ''PGE 2 -CDI-Tg'' (400mol PGE 2 per mol Tg) and ''PGA 2 -CDI-Tg'' (600mol PGA 2 per mol Tg). Two tracer systems ( 3 H-prostaglandin and 125 I-histamine-prostaglandin) were used for analysis of antibody activity. The PGE 2 -CDI-Tg and PGA 2 -CDI-Tg complexes were both poor immunogens in rabbits. The PGE 2 -OSU-Tg and PGA 2 -OSU-Tg conjugates were injected in rabbits and in guinea-pigs. These two compounds resulted in very high antibody titres in both animal species. However, in guinea-pigs a markedly higher antibody sensitivity and antibody specificity were observed than in rabbits. Our results indicate that the guinea-pig may be the animal of choice for immunization against prostaglandins. Antibody specificity of guinea-pig antisera may be high enough to measure the concentration of PGE 2 and PGA 2 in the presence of other prostaglandins or prostaglandin metabolites. (author)

  17. Problems connected with the production of highly specific antisera against prostaglandin E2 (PGE2) and prostaglandin A2 (PGA2) for radioimmunoassay

    International Nuclear Information System (INIS)

    Kopp, H.G.; Vetter, W.; Siegenthaler, W.

    1977-01-01

    To obtain sensitive and specific antisera against PGE 2 and PGA 2 these substances were coupled to thyroglobulin (Tg). Coupling reactions were either performed by using a hydroxysuccinimideester as intermediate step leading to a complex carrying 170 mol PGE 2 per mol Tg ('PGE 2 -OSU-Tg') and 240 mol PGA 2 per mol Tg ('PGA 2 -OSU-Tg') or alternatively by using N,N'-carbonyl-diimidazole resulting in 'PGE 2 -CDI-Tg' (400 mol PGE 2 per mol Tg) and 'PGA 2 -CDI-Tg' (600 mol PGA 2 per mol Tg). Two tracer systems ( 3 H-prostaglandin, 125 I-histamine-prostaglandin) were used for analysis of antibody activity. Both PGE 2 - and PGA 2 -CDI-Tg complexes were poor immunogens in rabbits. The PGE 2 - and PGA 2 -OSU-Tg conjugates were injected both in rabbits and in guinea pigs. These two compounds resulted in very high antibody titers in both animal species. However, in guinea pigs markedly higher antibody sensitivity and antibody specificity were observed than in rabbits. Our results indicate that the guinea pig may be the animal of choice for immunization against prostaglandins. Antibody specificity of guinea pig antisera may be perhaps high enough to measure the concentration of PGE 2 and PGA 2 in the presence of other prostaglandins or prostaglandin metabolites. (orig.) [de

  18. AeroADL: applying the integration of the Suomi-NPP science algorithms with the Algorithm Development Library to the calibration and validation task

    Science.gov (United States)

    Houchin, J. S.

    2014-09-01

    A common problem for the off-line validation of the calibration algorithms and algorithm coefficients is being able to run science data through the exact same software used for on-line calibration of that data. The Joint Polar Satellite System (JPSS) program solved part of this problem by making the Algorithm Development Library (ADL) available, which allows the operational algorithm code to be compiled and run on a desktop Linux workstation using flat file input and output. However, this solved only part of the problem, as the toolkit and methods to initiate the processing of data through the algorithms were geared specifically toward the algorithm developer, not the calibration analyst. In algorithm development mode, a limited number of sets of test data are staged for the algorithm once, and then run through the algorithm over and over as the software is developed and debugged. In calibration analyst mode, we are continually running new data sets through the algorithm, which requires significant effort to stage each of those data sets for the algorithm without additional tools. AeroADL solves this second problem by providing a set of scripts that wrap the ADL tools, providing both efficient means to stage and process an input data set, to override static calibration coefficient look-up-tables (LUT) with experimental versions of those tables, and to manage a library containing multiple versions of each of the static LUT files in such a way that the correct set of LUTs required for each algorithm are automatically provided to the algorithm without analyst effort. Using AeroADL, The Aerospace Corporation's analyst team has demonstrated the ability to quickly and efficiently perform analysis tasks for both the VIIRS and OMPS sensors with minimal training on the software tools.

  19. Performance standard for dose Calibrator

    CERN Document Server

    Darmawati, S

    2002-01-01

    Dose calibrator is an instrument used in hospitals to determine the activity of radionuclide for nuclear medicine purposes. International Electrotechnical Commission (IEC) has published IEC 1303:1994 standard that can be used as guidance to test the performance of the instrument. This paper briefly describes content of the document,as well as explains the assessment that had been carried out to test the instrument accuracy in Indonesia through intercomparison measurement.Its is suggested that hospitals acquire a medical physicist to perform the test for its dose calibrator. The need for performance standard in the form of Indonesia Standard is also touched.

  20. NIST display colorimeter calibration facility

    Science.gov (United States)

    Brown, Steven W.; Ohno, Yoshihiro

    2003-07-01

    A facility has been developed at the National Institute of Standards and Technology (NIST) to provide calibration services for color-measuring instruments to address the need for improving and certifying the measurement uncertainties of this type of instrument. While NIST has active programs in photometry, flat panel display metrology, and color and appearance measurements, these are the first services offered by NIST tailored to color-measuring instruments for displays. An overview of the facility, the calibration approach, and associated uncertainties are presented. Details of a new tunable colorimetric source and the development of new transfer standard instruments are discussed.

  1. Tank calibration; Arqueacao de tanques

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Ana [PETROBRAS S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    This work relates the analysis of the norms ISO (International Organization for Standardization) for calibration of vertical cylindrical tanks used in fiscal measurement, established on Joint Regulation no 1 of June 19, 2000 between the ANP (National Agency of Petroleum) and the INMETRO (National Institute of Metrology, Normalization and Industrial Quality). In this work a comparison between norms ISO and norms published by the API (American Petroleum Institute) and the IP (Institute of Petroleum) up to 2001 was made. It was concluded that norms ISO are wider than norms API, IP, and INMETRO methods in the calibration of vertical cylindrical tanks. (author)

  2. Thermodynamically consistent model calibration in chemical kinetics

    Directory of Open Access Journals (Sweden)

    Goutsias John

    2011-05-01

    Full Text Available Abstract Background The dynamics of biochemical reaction systems are constrained by the fundamental laws of thermodynamics, which impose well-defined relationships among the reaction rate constants characterizing these systems. Constructing biochemical reaction systems from experimental observations often leads to parameter values that do not satisfy the necessary thermodynamic constraints. This can result in models that are not physically realizable and may lead to inaccurate, or even erroneous, descriptions of cellular function. Results We introduce a thermodynamically consistent model calibration (TCMC method that can be effectively used to provide thermodynamically feasible values for the parameters of an open biochemical reaction system. The proposed method formulates the model calibration problem as a constrained optimization problem that takes thermodynamic constraints (and, if desired, additional non-thermodynamic constraints into account. By calculating thermodynamically feasible values for the kinetic parameters of a well-known model of the EGF/ERK signaling cascade, we demonstrate the qualitative and quantitative significance of imposing thermodynamic constraints on these parameters and the effectiveness of our method for accomplishing this important task. MATLAB software, using the Systems Biology Toolbox 2.1, can be accessed from http://www.cis.jhu.edu/~goutsias/CSS lab/software.html. An SBML file containing the thermodynamically feasible EGF/ERK signaling cascade model can be found in the BioModels database. Conclusions TCMC is a simple and flexible method for obtaining physically plausible values for the kinetic parameters of open biochemical reaction systems. It can be effectively used to recalculate a thermodynamically consistent set of parameter values for existing thermodynamically infeasible biochemical reaction models of cellular function as well as to estimate thermodynamically feasible values for the parameters of new

  3. Model Robust Calibration: Method and Application to Electronically-Scanned Pressure Transducers

    Science.gov (United States)

    Walker, Eric L.; Starnes, B. Alden; Birch, Jeffery B.; Mays, James E.

    2010-01-01

    This article presents the application of a recently developed statistical regression method to the controlled instrument calibration problem. The statistical method of Model Robust Regression (MRR), developed by Mays, Birch, and Starnes, is shown to improve instrument calibration by reducing the reliance of the calibration on a predetermined parametric (e.g. polynomial, exponential, logarithmic) model. This is accomplished by allowing fits from the predetermined parametric model to be augmented by a certain portion of a fit to the residuals from the initial regression using a nonparametric (locally parametric) regression technique. The method is demonstrated for the absolute scale calibration of silicon-based pressure transducers.

  4. Hot-Wire Calibration at Low Velocities: Revisiting the Vortex Shedding Method

    Directory of Open Access Journals (Sweden)

    Sohrab S. Sattarzadeh

    2013-01-01

    Full Text Available The necessity to calibrate hot-wire probes against a known velocity causes problems at low velocities, due to the inherent inaccuracy of pressure transducers at low differential pressures. The vortex shedding calibration method is in this respect a recommended technique to obtain calibration data at low velocities, due to its simplicity and accuracy. However, it has mainly been applied in a low and narrow Reynolds number range known as the laminar vortex shedding regime. Here, on the other hand, we propose to utilize the irregular vortex shedding regime and show where the probe needs to be placed with respect to the cylinder in order to obtain unambiguous calibration data.

  5. A portable, automated, inexpensive mass and balance calibration system

    International Nuclear Information System (INIS)

    Maxwell, S.L. III; Clark, J.P.

    1987-01-01

    Reliable mass measurements are essential for a nuclear production facility or process control laboratory. DOE Order 5630.2 requires that traceable standards be used to calibrate and monitor equipment used for nuclear material measurements. To ensure the reliability of mass measurements and to comply with DOE traceable requirements, a portable, automated mass and balance calibration system is used at the Savannah River Plant. Automation is achieved using an EPSON HX-20 notebook computer, which can be operated via RS232C interfacing to electronic balances or function with manual data entry if computer interfacing is not feasible. This economical, comprehensive, user-friendly system has three main functions in a mass measurement control program (MMCP): balance certification, calibration of mass standards, and daily measurement of traceable standards. The balance certification program tests for accuracy, precision, sensitivity, linearity, and cornerloading versus specific requirements. The mass calibration program allows rapid calibration of inexpensive mass standards traceable to certified Class S standards. This MMCP permits daily measurement of traceable standards to monitor the reliability of balances during routine use. The automated system verifies balance calibration, stores results for future use, and provides a printed control chart of the stored data. Another feature of the system permits three different weighing routines that accommodate our need for varying degrees of reliability in routine weighing operations. 1 ref

  6. A portable, automated, inexpensive mass and balance calibration system

    International Nuclear Information System (INIS)

    Maxwell, S.L. III; Clark, J.P.

    1987-01-01

    Reliable mass measurements are essential for a nuclear production facility or process control laboratory. DOE Order 5630.2 requires that traceable standards be used to calibrate and monitor equipment used for nuclear material measurements. To ensure the reliability of mass measurements and to comply with DOE traceability requirements, a portable, automated mass and balance calibration system is used at the Savannah River Plant. Automation is achieved using an EPSON HX-20 notebook computer, which can be operated via RS232C interfacing to electronic balances or function with manual data entry if computer interfacing is not feasible. This economical, comprehensive, user-friendly system has three main functions in a mass measurement control program (MMCP): balance certification, calibration of mass standards, and daily measurement of traceable standards. The balance certification program tests for accuracy, precision, sensitivity, linearity, and cornerloading versus specific requirements. The mass calibration program allows rapid calibration of inexpensive mass standards traceable to certified Class S standards. This MMCP permits daily measurement of traceable standards to monitor the reliability of balances during routine use. The automated system verifies balance calibration, stores results for future use, and provides a printed control chart of the stored data. Another feature of the system permits three different weighing routines that accommodate their need for varying degrees of reliability in routine weighing operations

  7. Using Active Learning for Speeding up Calibration in Simulation Models.

    Science.gov (United States)

    Cevik, Mucahit; Ergun, Mehmet Ali; Stout, Natasha K; Trentham-Dietz, Amy; Craven, Mark; Alagoz, Oguzhan

    2016-07-01

    Most cancer simulation models include unobservable parameters that determine disease onset and tumor growth. These parameters play an important role in matching key outcomes such as cancer incidence and mortality, and their values are typically estimated via a lengthy calibration procedure, which involves evaluating a large number of combinations of parameter values via simulation. The objective of this study is to demonstrate how machine learning approaches can be used to accelerate the calibration process by reducing the number of parameter combinations that are actually evaluated. Active learning is a popular machine learning method that enables a learning algorithm such as artificial neural networks to interactively choose which parameter combinations to evaluate. We developed an active learning algorithm to expedite the calibration process. Our algorithm determines the parameter combinations that are more likely to produce desired outputs and therefore reduces the number of simulation runs performed during calibration. We demonstrate our method using the previously developed University of Wisconsin breast cancer simulation model (UWBCS). In a recent study, calibration of the UWBCS required the evaluation of 378 000 input parameter combinations to build a race-specific model, and only 69 of these combinations produced results that closely matched observed data. By using the active learning algorithm in conjunction with standard calibration methods, we identify all 69 parameter combinations by evaluating only 5620 of the 378 000 combinations. Machine learning methods hold potential in guiding model developers in the selection of more promising parameter combinations and hence speeding up the calibration process. Applying our machine learning algorithm to one model shows that evaluating only 1.49% of all parameter combinations would be sufficient for the calibration. © The Author(s) 2015.

  8. Extrinsic Calibration of Camera and 2D Laser Sensors without Overlap

    Directory of Open Access Journals (Sweden)

    Khalil M. Ahmad Yousef

    2017-10-01

    Full Text Available Extrinsic calibration of a camera and a 2D laser range finder (lidar sensors is crucial in sensor data fusion applications; for example SLAM algorithms used in mobile robot platforms. The fundamental challenge of extrinsic calibration is when the camera-lidar sensors do not overlap or share the same field of view. In this paper we propose a novel and flexible approach for the extrinsic calibration of a camera-lidar system without overlap, which can be used for robotic platform self-calibration. The approach is based on the robot–world hand–eye calibration (RWHE problem; proven to have efficient and accurate solutions. First, the system was mapped to the RWHE calibration problem modeled as the linear relationship AX = ZB , where X and Z are unknown calibration matrices. Then, we computed the transformation matrix B , which was the main challenge in the above mapping. The computation is based on reasonable assumptions about geometric structure in the calibration environment. The reliability and accuracy of the proposed approach is compared to a state-of-the-art method in extrinsic 2D lidar to camera calibration. Experimental results from real datasets indicate that the proposed approach provides better results with an L2 norm translational and rotational deviations of 314 mm and 0 . 12 ∘ respectively.

  9. Extrinsic Calibration of Camera and 2D Laser Sensors without Overlap.

    Science.gov (United States)

    Ahmad Yousef, Khalil M; Mohd, Bassam J; Al-Widyan, Khalid; Hayajneh, Thaier

    2017-10-14

    Extrinsic calibration of a camera and a 2D laser range finder (lidar) sensors is crucial in sensor data fusion applications; for example SLAM algorithms used in mobile robot platforms. The fundamental challenge of extrinsic calibration is when the camera-lidar sensors do not overlap or share the same field of view. In this paper we propose a novel and flexible approach for the extrinsic calibration of a camera-lidar system without overlap, which can be used for robotic platform self-calibration. The approach is based on the robot-world hand-eye calibration (RWHE) problem; proven to have efficient and accurate solutions. First, the system was mapped to the RWHE calibration problem modeled as the linear relationship AX = ZB , where X and Z are unknown calibration matrices. Then, we computed the transformation matrix B , which was the main challenge in the above mapping. The computation is based on reasonable assumptions about geometric structure in the calibration environment. The reliability and accuracy of the proposed approach is compared to a state-of-the-art method in extrinsic 2D lidar to camera calibration. Experimental results from real datasets indicate that the proposed approach provides better results with an L2 norm translational and rotational deviations of 314 mm and 0 . 12 ∘ respectively.

  10. Scalar Calibration of Vector Magnetometers

    DEFF Research Database (Denmark)

    Merayo, José M.G.; Brauer, Peter; Primdahl, Fritz

    2000-01-01

    The calibration parameters of a vector magnetometer are estimated only by the use of a scalar reference magnetometer. The method presented in this paper differs from those previously reported in its linearized parametrization. This allows the determination of three offsets or signals in the absence...

  11. Uniformity calibration for ICT image

    International Nuclear Information System (INIS)

    Zeng Gang; Liu Li; Que Jiemin; Zhang Yingping; Yin Yin; Wang Yanfang; Yu Zhongqiang; Yan Yonglian

    2004-01-01

    The uniformity of ICT image is impaired by beam hardening and the inconsistency of detector units responses. The beam hardening and the nonlinearity of the detector's output have been analyzed. The correction factors are determined experimentally by the detector's responses with different absorption length. The artifacts in the CT image of a symmetrical aluminium cylinder have been eliminated after calibration. (author)

  12. Calibration of the Wedge Prism

    Science.gov (United States)

    Charles B. Briscoe

    1957-01-01

    Since the introduction of plotless cruising in this country by Grosenbaugh and the later suggestion of using a wedge prism as an angle gauge by Bruce this method of determining basal area has been widely adopted in the South. One of the factors contributing to the occasionally unsatisfactory results obtained is failure to calibrate the prism used. As noted by Bruce the...

  13. Bacterial contamination of ultrasound probes in different radiological institutions before and after specific hygiene training: do we have a general hygienical problem?

    Science.gov (United States)

    Sartoretti, Thomas; Sartoretti, Elisabeth; Bucher, Candid; Doert, Aleksis; Binkert, Christoph; Hergan, Klaus; Meissnitzer, Matthias; Froehlich, Johannes; Kolokythas, Orpheus; Matoori, Simon; Orasch, Christina; Kos, Sebastian; Sartoretti-Schefer, Sabine; Gutzeit, Andreas

    2017-10-01

    Aim was to investigate hygienic conditions of ultrasound probes before and after hygiene training in radiology institutions in comparison to bacterial contamination in public places. In three radiology departments, bacterial contamination was evaluated using baseline agar plates for cultures taken from 36 ultrasound probes. Afterwards teams were trained by a hygiene service centre and 36 ultrasound probes were routinely disinfected with regular disinfecting wipes and then evaluated. In comparison, bacterial contamination in public places (bus poles, n = 11; toilet seats, n = 10) were analysed. Plates were routinely incubated and the number of colony forming units (CFU) analysed. Cultures taken from the probes showed a median of 53 CFU before and 0 CFU after training (p contamination of ultrasound probes prior to hygiene training proved to be high and showed higher bacterial load than toilets seats or bus poles. Radiologists should be aware that the lack of hygiene in the field of ultrasound diagnostics puts patients at risk of healthcare-associated infections. • Hospital-associated infections are a problem for patient care. • Hygiene training of staff prevents bacterial contamination of ultrasound probes. • Disinfection of ultrasound probes is an easy method to protect patients.

  14. High Gain Antenna Calibration on Three Spacecraft

    Science.gov (United States)

    Hashmall, Joseph A.

    2011-01-01

    This paper describes the alignment calibration of spacecraft High Gain Antennas (HGAs) for three missions. For two of the missions (the Lunar Reconnaissance Orbiter and the Solar Dynamics Observatory) the calibration was performed on orbit. For the third mission (the Global Precipitation Measurement core satellite) ground simulation of the calibration was performed in a calibration feasibility study. These three satellites provide a range of calibration situations-Lunar orbit transmitting to a ground antenna for LRO, geosynchronous orbit transmitting to a ground antenna fer SDO, and low Earth orbit transmitting to TDRS satellites for GPM The calibration results depend strongly on the quality and quantity of calibration data. With insufficient data the calibration Junction may give erroneous solutions. Manual intervention in the calibration allowed reliable parameters to be generated for all three missions.

  15. Calibration of the clumped isotope thermometer for planktic foraminifers

    Science.gov (United States)

    Meinicke, N.; Ho, S. L.; Nürnberg, D.; Tripati, A. K.; Jansen, E.; Dokken, T.; Schiebel, R.; Meckler, A. N.

    2017-12-01

    Many proxies for past ocean temperature suffer from secondary influences or require species-specific calibrations that might not be applicable on longer time scales. Being thermodynamically based and thus independent of seawater composition, clumped isotopes in carbonates (Δ47) have the potential to circumvent such issues affecting other proxies and provide reliable temperature reconstructions far back in time and in unknown settings. Although foraminifers are commonly used for paleoclimate reconstructions, their use for clumped isotope thermometry has been hindered so far by large sample-size requirements. Existing calibration studies suggest that data from a variety of foraminifer species agree with synthetic carbonate calibrations (Tripati, et al., GCA, 2010; Grauel, et al., GCA, 2013). However, these studies did not include a sufficient number of samples to fully assess the existence of species-specific effects, and data coverage was especially sparse in the low temperature range (analysis of smaller sample sizes (3-5 mg), hence also the measurement of multiple species from the same samples. We analyzed surface-dwelling ( 0-50 m) species and deep-dwelling (habitat depth up to several hundred meters) planktic foraminifers from the same sites to evaluate species-specific effects and to assess the feasibility of temperature reconstructions for different water depths. We also assess the effects of different techniques in estimating foraminifer calcification temperature on the calibration. Finally, we compare our calibration to existing clumped isotope calibrations. Our results confirm previous findings that indicate no species-specific effects on the Δ47-temperature relationship measured in planktic foraminifers.

  16. Experiments on mobile robot stereo vision system calibration under hardware imperfection

    Directory of Open Access Journals (Sweden)

    Safin Ramil

    2018-01-01

    Full Text Available Calibration is essential for any robot vision system for achieving high accuracy in deriving objects metric information. One of typical requirements for a stereo vison system in order to obtain better calibration results is to guarantee that both cameras keep the same vertical level. However, cameras may be displaced due to severe conditions of a robot operating or some other circumstances. This paper presents our experimental approach to the problem of a mobile robot stereo vision system calibration under a hardware imperfection. In our experiments, we used crawler-type mobile robot «Servosila Engineer». Stereo system cameras of the robot were displaced relative to each other, causing loss of surrounding environment information. We implemented and verified checkerboard and circle grid based calibration methods. The two methods comparison demonstrated that a circle grid based calibration should be preferred over a classical checkerboard calibration approach.

  17. Drinking game play among first-year college student drinkers: an event-specific analysis of the risk for alcohol use and problems.

    Science.gov (United States)

    Ray, Anne E; Stapleton, Jerod L; Turrisi, Rob; Mun, Eun-Young

    2014-09-01

    College students who play drinking games (DGs) more frequently report higher levels of alcohol use and experience more alcohol-related harm. However, the extent to which they are at risk for increased consumption and harm as a result of DG play on a given event after accounting for their typical DG participation, and typical and event drinking, is unclear. We examined whether first-year students consumed more alcohol and were more likely to experience consequences on drinking occasions when they played DGs. Participants (n = 336) completed up to six web-based surveys following weekend drinking events in their first semester. Alcohol use, DG play, and consequences were reported for the Friday and Saturday prior to each survey. Typical DG tendencies were controlled in all models. Typical and event alcohol use were controlled in models predicting risk for consequences. Participants consumed more alcohol on DG versus non-DG events. All students were more likely to experience blackout drinking consequences when they played DGs. Women were more likely to experience social-interpersonal consequences when they played DGs. DG play is an event-specific risk factor for increased alcohol use among first-year students, regardless of individual DG play tendencies. Further, event DG play signals increased risk for blackout drinking consequences for all students, and social-interpersonal consequences for women, aside from the amount of alcohol consumed on those occasions as well as typical drinking behaviors. Prevention efforts to reduce high-risk drinking may be strengthened by highlighting both event- and person-specific risks of DG play.

  18. The Fundamentals of the Air Sampler Calibration-Verification Process

    International Nuclear Information System (INIS)

    Gavila, F.M.

    2011-01-01

    The calibration of an air sampling instrument using a reference air flow calibrator requires attention to scientific detail in order to establish that the instrument's reported values are correctly stated and valid under the actual operating conditions of the air sampling instrument. The primary objective of an air flow calibration-verification is to ensure that the device under test (DUT) is within the manufacturer's stated accuracy range of temperature, pressure and humidity conditions under which the instrument was designed to operate. The DUT output values are compared to those obtained from a reference instrument (REF) measuring the sample physical parameter that the DUT is measuring. An accurate comparison of air flow rates or air volumes requires that the comparison of the DUT and REF values be made under the same temperature and pressure conditions. It is absolutely necessary that the REF be more accurate than the DUT; otherwise, it can not be considered a reference instrument. The REF should be at least twice as accurate and, if possible, it should be four times as accurate as the DUT. Upon confirmation that the DUT meets the manufacturer's accuracy criteria, the technician must place a calibration sticker or label indicating the date of calibration, the expiration date of the calibration and an authorized signature. If it is a limited-use instrument, the label should state the limited-use operating range. The serial number and model number of the instrument should also be shown on the calibration sticker. A specific calibration file for each instrument by serial number should be kept in the calibration laboratory file records. Instruments that display gas flow or gas volume values corrected to a reference temperature and pressure are very desirable. The ideal situation is when both the DUT and the REF output flow rate or volume values are at the same conditions of T and P. The calibration-verification is, then, a simple process. The credibility of an air

  19. Instrument calibration optimization at Bruce Power: ECI loops

    Energy Technology Data Exchange (ETDEWEB)

    Chugh, V.; Angelova, M.; Ghias, S.; Parmar, R.; Wang, V.; Xie, H. [AMEC NSS, Toronto, Ontario (Canada); Higgs, J.; Schut, J.; Cruchley, I. [Bruce Power, Tiverton, Ontario (Canada)

    2011-07-01

    Most instruments in a nuclear power plant are calibrated at regular intervals to ensure consistency with the assumptions in the plant Technical Specifications and/or Safe Operating Envelope (SOE) compliance limits (e.g., As-Found Tolerance). In the Instrument Uncertainty Calculations (IUC), As-Found Tolerance for instrument drift is estimated based on statistical analysis of As-Found and As-Left calibration data such as that carried out for Bruce NGS by EPRI (Electric Power Research Institute) in 1998. Bruce specific drift values were found to compare favorably with industry benchmarks. Recently a significant amount of work has been done by EPRI and IAEA (International Atomic Energy Agency) on extending calibration intervals of safety related instruments. Reduction in calibration frequency reduces time commitments on the part of Authorized Nuclear Operators and safety system qualified Control Maintenance Technicians, and allows more schedule flexibility. To establish the proof of concept, As-Left/As-Found tolerances and available margins have been evaluated for the Bruce B Emergency Coolant Injection (ECI) system instrument loops to determine whether an extension of the calibration period from one or two year to three years is justifiable on the basis that these loops will still be in compliance with SOE. The analysis showed that 60% of instruments in the ECI system are qualified for calibration interval extension up to three years. Sensitivity assessment of the effect of proposed changes in calibration intervals for 60% of the instruments on the ECI system unavailability has also been performed using the current Bruce Power ECI unavailability model. The results show that, the largest ECI Predicted Future Unavailability (PFU) is 9.2E-4 year/year for in-core LOCA accident. This value is still below the target unavailability of 1.0E-3 year/year. (author)

  20. Instrument calibration optimization at Bruce Power: ECI loops

    International Nuclear Information System (INIS)

    Chugh, V.; Angelova, M.; Ghias, S.; Parmar, R.; Wang, V.; Xie, H.; Higgs, J.; Schut, J.; Cruchley, I.

    2011-01-01

    Most instruments in a nuclear power plant are calibrated at regular intervals to ensure consistency with the assumptions in the plant Technical Specifications and/or Safe Operating Envelope (SOE) compliance limits (e.g., As-Found Tolerance). In the Instrument Uncertainty Calculations (IUC), As-Found Tolerance for instrument drift is estimated based on statistical analysis of As-Found and As-Left calibration data such as that carried out for Bruce NGS by EPRI (Electric Power Research Institute) in 1998. Bruce specific drift values were found to compare favorably with industry benchmarks. Recently a significant amount of work has been done by EPRI and IAEA (International Atomic Energy Agency) on extending calibration intervals of safety related instruments. Reduction in calibration frequency reduces time commitments on the part of Authorized Nuclear Operators and safety system qualified Control Maintenance Technicians, and allows more schedule flexibility. To establish the proof of concept, As-Left/As-Found tolerances and available margins have been evaluated for the Bruce B Emergency Coolant Injection (ECI) system instrument loops to determine whether an extension of the calibration period from one or two year to three years is justifiable on the basis that these loops will still be in compliance with SOE. The analysis showed that 60% of instruments in the ECI system are qualified for calibration interval extension up to three years. Sensitivity assessment of the effect of proposed changes in calibration intervals for 60% of the instruments on the ECI system unavailability has also been performed using the current Bruce Power ECI unavailability model. The results show that, the largest ECI Predicted Future Unavailability (PFU) is 9.2E-4 year/year for in-core LOCA accident. This value is still below the target unavailability of 1.0E-3 year/year. (author)

  1. Direct calibration of the yield of nuclear explosion

    International Nuclear Information System (INIS)

    Nakanishi, K.; Nikolayev, A.

    1994-06-01

    The determination of the power of underground nuclear explosions (UNE) is of great significance. The seismic method of UNE yield determination allows monitoring at large distances, but is less precise than local monitoring methods. A way is proposed to calibrate UNE based on the idea of the vibroseis method in which powerful vibrators are used to produce seismic waves in the UNE epicenter; UNE calibration is carried out by comparison of the vibroseis record with a UNE seismogram. Results of preliminary work on the problem are presented. It is based on experience with vibrosounding of the Earth as well as earthquakes and chemical and nuclear explosions wave field structure studies. It is concluded that UNE calibration with the aid of seismic vibrators is both possible and expedient

  2. Inherent calibration of microdosemeters for dose distributions in lineal energy

    Energy Technology Data Exchange (ETDEWEB)

    Crossman, J.S.P.; Watt, D.E. [Saint Andrews Univ. (United Kingdom). Dept. of Physics and Astronomy

    1994-12-31

    A method, utilising the inherent electron event spectra, is described for the absolute calibration of microdosemeters in the presence of a photon field. The method, which avoids the problems and uncertainties present in conventional calibration techniques, involves simple extrapolation of the dose distribution in lineal energy associated with `exact stopper` electrons. Validation of the method is made using the published experimental distributions of Rossi, of Kliauga, and of Dvorak and by direct theoretical calculation of the components of the microdose distributions for gamma rays. Further experimental data from a cylindrical TEPC in a photon field generated by an external source of {sup 137}Cs are obtained for comparison. A `universal` calibration curve for the dose-weighted lineal energy as a function of the simulated mean diameter of the microdosemeter, is presented for use in practical applications. (author).

  3. Inherent calibration of microdosemeters for dose distributions in lineal energy

    International Nuclear Information System (INIS)

    Crossman, J.S.P.; Watt, D.E.

    1994-01-01

    A method, utilising the inherent electron event spectra, is described for the absolute calibration of microdosemeters in the presence of a photon field. The method, which avoids the problems and uncertainties present in conventional calibration techniques, involves simple extrapolation of the dose distribution in lineal energy associated with 'exact stopper' electrons. Validation of the method is made using the published experimental distributions of Rossi, of Kliauga, and of Dvorak and by direct theoretical calculation of the components of the microdose distributions for gamma rays. Further experimental data from a cylindrical TEPC in a photon field generated by an external source of 137 Cs are obtained for comparison. A 'universal' calibration curve for the dose-weighted lineal energy as a function of the simulated mean diameter of the microdosemeter, is presented for use in practical applications. (author)

  4. A Novel Approach to Calibrating Multifunctional Binocular Stereovision Sensor

    International Nuclear Information System (INIS)

    Xue, T; Zhu, J G; Wu, B; Ye, S H

    2006-01-01

    We present a novel multifunctional binocular stereovision sensor for various threedimensional (3D) inspection tasks. It not only avoids the so-called correspondence problem of passive stereo vision, but also possesses the uniform mathematical model. We also propose a novel approach to estimating all the sensor parameters with free-position planar reference object. In this technique, the planar pattern can be moved freely by hand. All the camera intrinsic and extrinsic parameters with coefficient of lens radial and tangential distortion are estimated, and sensor parameters are calibrated based on the 3D measurement model and optimized with the feature point constraint algorithm using the same views in the camera calibration stage. The proposed approach greatly reduces the cost of the calibration equipment, and it is flexible and practical for the vision measurement. It shows that this method has high precision by experiment, and the sensor measured relative error of space length excels 0.3%

  5. Mass and stiffness calibration of nanowires using thermally driven vibration

    International Nuclear Information System (INIS)

    Kiracofe, D R; Raman, A; Yazdanpanah, M M

    2011-01-01

    Cantilevered or suspended nanowires show promise for force or mass sensing applications due to their small mass, high force sensitivity and high frequency bandwidth. To use these as quantitative sensors, their bending stiffness or mass must be calibrated experimentally, often using thermally driven vibration. However, this can be difficult because nanowires are slightly asymmetric, which results in two spatially orthogonal bending eigenmodes with closely spaced frequencies. This asymmetry presents problems for traditional stiffness calibration methods, which equate the measured thermal vibration spectrum near a resonance to that of a single eigenmode. Moreover, the principal axes may be arbitrarily rotated with respect to the measurement direction. In this work, the authors propose a method for calibrating the bending stiffness and mass of such nanowires' eigenmodes using a single measurement taken at an arbitrary orientation with respect to the principal axes.

  6. On the expression 'external calibration' in atomic spectrometry

    International Nuclear Information System (INIS)

    Kantor, Tibor

    2008-01-01

    The expressions 'calibration' and 'external calibration' appear together in the present literature of atomic spectrometry resulting in a dilemma of understanding and correct use. It is examined how the IUPAC can provide a guidance to the solution of this problem by recalling the definitions of related terms of optical, mass and X-ray atomic spectrometry techniques. The introduction and definition of these expressions in widely used text books are investigated and statistically evaluated for the articles published during the last 30 years in the periodical Spectrochimica Acta Part B. For the elimination of the literary difficulties with the use of the term 'calibration', attributes are proposed to express the degree of matrix matching of standards and samples

  7. Hybrid Geometric Calibration Method for Multi-Platform Spaceborne SAR Image with Sparse Gcps

    Science.gov (United States)

    Lv, G.; Tang, X.; Ai, B.; Li, T.; Chen, Q.

    2018-04-01

    Geometric calibration is able to provide high-accuracy geometric coordinates of spaceborne SAR image through accurate geometric parameters in the Range-Doppler model by ground control points (GCPs). However, it is very difficult to obtain GCPs that covering large-scale areas, especially in the mountainous regions. In addition, the traditional calibration method is only used for single platform SAR images and can't support the hybrid geometric calibration for multi-platform images. To solve the above problems, a hybrid geometric calibration method for multi-platform spaceborne SAR images with sparse GCPs is proposed in this paper. First, we calibrate the master image that contains GCPs. Secondly, the point tracking algorithm is used to obtain the tie points (TPs) between the master and slave images. Finally, we calibrate the slave images using TPs as the GCPs. We take the Beijing-Tianjin- Hebei region as an example to study SAR image hybrid geometric calibration method using 3 TerraSAR-X images, 3 TanDEM-X images and 5 GF-3 images covering more than 235 kilometers in the north-south direction. Geometric calibration of all images is completed using only 5 GCPs. The GPS data extracted from GNSS receiver are used to assess the plane accuracy after calibration. The results after geometric calibration with sparse GCPs show that the geometric positioning accuracy is 3 m for TSX/TDX images and 7.5 m for GF-3 images.

  8. The cost of uniqueness in groundwater model calibration

    Science.gov (United States)

    Moore, Catherine; Doherty, John

    2006-04-01

    Calibration of a groundwater model requires that hydraulic properties be estimated throughout a model domain. This generally constitutes an underdetermined inverse problem, for which a solution can only be found when some kind of regularization device is included in the inversion process. Inclusion of regularization in the calibration process can be implicit, for example through the use of zones of constant parameter value, or explicit, for example through solution of a constrained minimization problem in which parameters are made to respect preferred values, or preferred relationships, to the degree necessary for a unique solution to be obtained. The "cost of uniqueness" is this: no matter which regularization methodology is employed, the inevitable consequence of its use is a loss of detail in the calibrated field. This, in turn, can lead to erroneous predictions made by a model that is ostensibly "well calibrated". Information made available as a by-product of the regularized inversion process allows the reasons for this loss of detail to be better understood. In particular, it is easily demonstrated that the estimated value for an hydraulic property at any point within a model domain is, in fact, a weighted average of the true hydraulic property over a much larger area. This averaging process causes loss of resolution in the estimated field. Where hydraulic conductivity is the hydraulic property being estimated, high averaging weights exist in areas that are strategically disposed with respect to measurement wells, while other areas may contribute very little to the estimated hydraulic conductivity at any point within the model domain, this possibly making the detection of hydraulic conductivity anomalies in these latter areas almost impossible. A study of the post-calibration parameter field covariance matrix allows further insights into the loss of system detail incurred through the calibration process to be gained. A comparison of pre- and post-calibration

  9. In pursuit of precision: the calibration of minds and machines in late nineteenth-century psychology.

    Science.gov (United States)

    Benschop, R; Draaisma, D

    2000-01-01

    A prominent feature of late nineteenth-century psychology was its intense preoccupation with precision. Precision was at once an ideal and an argument: the quest for precision helped psychology to establish its status as a mature science, sharing a characteristic concern with the natural sciences. We will analyse how psychologists set out to produce precision in 'mental chronometry', the measurement of the duration of psychological processes. In his Leipzig laboratory, Wundt inaugurated an elaborate research programme on mental chronometry. We will look at the problem of calibration of experimental apparatus and will describe the intricate material, literary, and social technologies involved in the manufacture of precision. First, we shall discuss some of the technical problems involved in the measurement of ever shorter time-spans. Next, the Cattell-Berger experiments will help us to argue against the received view that all the precision went into the hardware, and practically none into the social organization of experimentation. Experimenters made deliberate efforts to bring themselves and their subjects under a regime of control and calibration similar to that which reigned over the experimental machinery. In Leipzig psychology, the particular blend of material and social technology resulted in a specific object of study: the generalized mind. We will then show that the distribution of precision in experimental psychology outside Leipzig demanded a concerted effort of instruments, texts, and people. It will appear that the forceful attempts to produce precision and uniformity had some rather paradoxical consequences.

  10. Calibration of LOFAR data on the cloud

    Science.gov (United States)

    Sabater, J.; Sánchez-Expósito, S.; Best, P.; Garrido, J.; Verdes-Montenegro, L.; Lezzi, D.

    2017-04-01

    New scientific instruments are starting to generate an unprecedented amount of data. The Low Frequency Array (LOFAR), one of the Square Kilometre Array (SKA) pathfinders, is already producing data on a petabyte scale. The calibration of these data presents a huge challenge for final users: (a) extensive storage and computing resources are required; (b) the installation and maintenance of the software required for the processing is not trivial; and (c) the requirements of calibration pipelines, which are experimental and under development, are quickly evolving. After encountering some limitations in classical infrastructures like dedicated clusters, we investigated the viability of cloud infrastructures as a solution. We found that the installation and operation of LOFAR data calibration pipelines is not only possible, but can also be efficient in cloud infrastructures. The main advantages were: (1) the ease of software installation and maintenance, and the availability of standard APIs and tools, widely used in the industry; this reduces the requirement for significant manual intervention, which can have a highly negative impact in some infrastructures; (2) the flexibility to adapt the infrastructure to the needs of the problem, especially as those demands change over time; (3) the on-demand consumption of (shared) resources. We found that a critical factor (also in other infrastructures) is the availability of scratch storage areas of an appropriate size. We found no significant impediments associated with the speed of data transfer, the use of virtualization, the use of external block storage, or the memory available (provided a minimum threshold is reached). Finally, we considered the cost-effectiveness of a commercial cloud like Amazon Web Services. While a cloud solution is more expensive than the operation of a large, fully-utilized cluster completely dedicated to LOFAR data reduction, we found that its costs are competitive if the number of datasets to be

  11. Lyman alpha SMM/UVSP absolute calibration and geocoronal correction

    Science.gov (United States)

    Fontenla, Juan M.; Reichmann, Edwin J.

    1987-01-01

    Lyman alpha observations from the Ultraviolet Spectrometer Polarimeter (UVSP) instrument of the Solar Maximum Mission (SMM) spacecraft were analyzed and provide instrumental calibration details. Specific values of the instrument quantum efficiency, Lyman alpha absolute intensity, and correction for geocoronal absorption are presented.

  12. Calibration method for direct conversion receiver front-ends

    Directory of Open Access Journals (Sweden)

    R. Müller

    2008-05-01

    Full Text Available Technology induced process tolerances in analog circuits cause device characteristics different from specification. For direct conversion receiver front-ends a system level calibration method is presented. The malfunctions of the devices are compensated by tuning dominant circuit parameters. Thereto optimization techniques are applied which use measurement values and special evaluation functions.

  13. Calibration of dosemeters and survey instruments for photon

    International Nuclear Information System (INIS)

    Alamares, A.L.; Caseria, E.S.

    1995-01-01

    The Philippine Nuclear Research Institute (PNRI), the country's regulatory agency, through its Radiation Protection Unit of the Nuclear Regulations Licensing and Safeguard Division provides the calibration services of nuclear instruments used by various institutions. The periodic calibration and standardization of radiation and protection survey instruments are done to insure correct and valid radiation readings. It is also a regulatory requirement for radiation workers to use only operable and precalibrated survey instruments for their work with radioactive materials. The PNRI maintains and operates the Secondary Standard Dosimetry Laboratory (SSDL). It provides the periodic calibration and standardization of radiation monitoring and protection survey instruments, and also the radiological hazard and performance evaluation surveys of radiotherapy facilities and others. For the calibration of survey instruments, the standard sources of Cs-137 and Co-60 are used. The calibration procedures for survey meters and pocket dosimeters are explained. The clients served are shown. The personnel dosimetry using film badges, the application of ICRU operational quantities, and the problems encountered and recommendations are reported. (K.I.)

  14. Calibration apparatus for precise barometers and vacuum gauges

    International Nuclear Information System (INIS)

    Woo, S.Y.; Choi, I.M.; Lee, Y.J.; Hong, S.S.; Chung, K.H.

    2004-01-01

    In order to calibrate highly accurate absolute pressure gauges, such as barometers and vacuum gauges, laser, or ultrasonic mercury manometers have been used. However, the complexity and cost of manometers have greatly reduced the use of this method in most calibration laboratories. As a substitute, a gas-operated pressure balance is used to calibrate precise gauges. In such cases, many commercially available pressure balances are unsuitable because the necessary exposure of the piston, cylinder, and masses to the atmosphere causes contamination problems and allows dust particles into the gap between the piston and cylinder. In this article, a weight-loading device is described that allows masses to be changed in situ without breaking the vacuum. This device makes it possible to add or remove weights easily during the calibration, thereby greatly reducing the time between observations. Using this device, we efficiently calibrated a precise quartz resonance barometer (Paroscientific, model 760-16B) over a pressure range of 940-1050 h Pa and a precise vacuum gauge (MKS, CDG 100 Torr) over a pressure range of 0-100 h Pa

  15. Fast film dosimetry calibration method for IMRT treatment plan verification

    International Nuclear Information System (INIS)

    Schwob, N.; Wygoda, A.

    2004-01-01

    Intensity-Modulated Radiation Therapy (IMRT) treatments are delivered dynamically and as so, require routinely performed verification measurements [1]. Radiographic film dosimetry is a well-adapted method for integral measurements of dynamic treatments fields, with some drawbacks related to the known problems of dose calibration of films. Classically, several films are exposed to increasing doses, and a Net Optical Density (N.O.D) vs. dose sensitometric curve (S.C.) is generated. In order to speed up the process, some authors have developed a method based on the irradiation of a single film with a non-uniform pattern of O.D., delivered with a dynamic MLC. However, this curve still needs to be calibrated to dose by the means of measurements in a water phantom. It is recommended to make a new calibration for every series of measurements, in order to avoid the processing quality dependence of the film response. These frequent measurements are very time consuming. We developed a simple method for quick dose calibration of films, including a check of the accuracy of the calibration curve obtained

  16. Matching Images to Models: Camera Calibration for 3-D Surface Reconstruction

    Science.gov (United States)

    Morris, Robin D.; Smelyanskiy, Vadim N.; Cheeseman. Peter C.; Norvig, Peter (Technical Monitor)

    2001-01-01

    In a previous paper we described a system which recursively recovers a super-resolved three dimensional surface model from a set of images of the surface. In that paper we assumed that the camera calibration for each image was known. In this paper we solve two problems. Firstly, if an estimate of the surface is already known, the problem is to calibrate a new image relative to the existing surface model. Secondly, if no surface estimate is available, the relative camera calibration between the images in the set must be estimated. This will allow an initial surface model to be estimated. Results of both types of estimation are given.

  17. Optimized calibration of neutronic-thermodynamic simulator for low power fast reactors

    International Nuclear Information System (INIS)

    Jachic, J.; Waintraub, M.

    1986-01-01

    Aiming to a general optimization of the project, controlled fuel depletion and management and yet motivated the feasibility of application of the SIRZ simulator to solve such problem, we present here an optimized and systematic calibration of this simulator. Are shown explicitly the control variables and the corresponding calibration equations for the buckling factors. After iterative linearizations, the resultant Linear Programming Problems were solved by the SIMPLEX Method. The results show that the optimum calibration is easily obtained if convergence control parameters are adequately chosen. (Author) [pt

  18. SMAP RADAR Calibration and Validation

    Science.gov (United States)

    West, R. D.; Jaruwatanadilok, S.; Chaubel, M. J.; Spencer, M.; Chan, S. F.; Chen, C. W.; Fore, A.

    2015-12-01

    The Soil Moisture Active Passive (SMAP) mission launched on Jan 31, 2015. The mission employs L-band radar and radiometer measurements to estimate soil moisture with 4% volumetric accuracy at a resolution of 10 km, and freeze-thaw state at a resolution of 1-3 km. Immediately following launch, there was a three month instrument checkout period, followed by six months of level 1 (L1) calibration and validation. In this presentation, we will discuss the calibration and validation activities and results for the L1 radar data. Early SMAP radar data were used to check commanded timing parameters, and to work out issues in the low- and high-resolution radar processors. From April 3-13 the radar collected receive only mode data to conduct a survey of RFI sources. Analysis of the RFI environment led to a preferred operating frequency. The RFI survey data were also used to validate noise subtraction and scaling operations in the radar processors. Normal radar operations resumed on April 13. All radar data were examined closely for image quality and calibration issues which led to improvements in the radar data products for the beta release at the end of July. Radar data were used to determine and correct for small biases in the reported spacecraft attitude. Geo-location was validated against coastline positions and the known positions of corner reflectors. Residual errors at the time of the beta release are about 350 m. Intra-swath biases in the high-resolution backscatter images are reduced to less than 0.3 dB for all polarizations. Radiometric cross-calibration with Aquarius was performed using areas of the Amazon rain forest. Cross-calibration was also examined using ocean data from the low-resolution processor and comparing with the Aquarius wind model function. Using all a-priori calibration constants provided good results with co-polarized measurements matching to better than 1 dB, and cross-polarized measurements matching to about 1 dB in the beta release. During the

  19. On-line testing of response time and calibration of temperature and pressure sensors in nuclear power plants

    International Nuclear Information System (INIS)

    Hashemian, H.M.

    1995-01-01

    Periodic calibrations and response time measurements are necessary for temperature and pressure sensors in the safety systems of nuclear power plants. Conventional measurement methods require the test to be performed at the sensor location or involve removing the sensor from the process and performing the tests in a laboratory or on the bench. The conventional methods are time consuming and have the potential of causing wear and tear on the equipment, can expose the test personnel to radiation and other harsh environments, and increase the length of the plant outage. Also, the conventional methods do not account for the installation effects which may have an influence on sensor performance. On-line testing methods alleviate these problems by providing remote sensor response time and calibration capabilities. For temperature sensors such as Resistance Temperature Detectors (RTDs) and thermocouples, an on-line test method called the Loop Current Step Response (LCSR) technique has been developed, and for pressure transmitters, an on-line method called noise analysis which was available for reactor diagnostics was validated for response time testing applications. Both the LCSR and noise analysis tests are performed periodically in U.S. nuclear power plants to meet the plant technical specification requirements for response time testing of safety-related sensors. Automated testing of the calibration of both temperature and pressure sensors can be accomplished through an on-line monitoring system installed in the plant. The system monitors the DC output of the sensors over the fuel cycle to determine if any calibration drift has occurred. Changes in calibration can be detected using signal averaging and intercomparison methods and analytical redundancy techniques. (author)

  20. Automated Calibration of Dosimeters for Diagnostic Radiology

    International Nuclear Information System (INIS)

    Romero Acosta, A.; Gutierrez Lores, S.

    2015-01-01

    Calibration of dosimeters for diagnostic radiology includes current and charge measurements, which are often repetitive. However, these measurements are usually done using modern electrometers, which are equipped with an RS-232 interface that enables instrument control from a computer. This paper presents an automated system aimed to the measurements for the calibration of dosimeters used in diagnostic radiology. A software application was developed, in order to achieve the acquisition of the electric charge readings, measured values of the monitor chamber, calculation of the calibration coefficient and issue of a calibration certificate. A primary data record file is filled and stored in the computer hard disk. The calibration method used was calibration by substitution. With this system, a better control over the calibration process is achieved and the need for human intervention is reduced. the automated system will be used in the calibration of dosimeters for diagnostic radiology at the Cuban Secondary Standard Dosimetry Laboratory of the Center for Radiation Protection and Hygiene. (Author)

  1. Crop physiology calibration in the CLM

    Directory of Open Access Journals (Sweden)

    I. Bilionis

    2015-04-01

    scalable and adaptive scheme based on sequential Monte Carlo (SMC. The model showed significant improvement of crop productivity with the new calibrated parameters. We demonstrate that the calibrated parameters are applicable across alternative years and different sites.

  2. Calibration of alpha surface contamination monitor

    International Nuclear Information System (INIS)

    Freitas, I.S.M. de; Goncalez, O.L.

    1990-01-01

    In this work, the results, as well as the methodology, of the calibration of an alpha surface contamination monitor are presented. The calibration factors are obtained by least-squares fitting with effective variance. (author)

  3. Calibration curves for biological dosimetry

    International Nuclear Information System (INIS)

    Guerrero C, C.; Brena V, M. . E-mail cgc@nuclear.inin.mx

    2004-01-01

    The generated information by the investigations in different laboratories of the world, included the ININ, in which settles down that certain class of chromosomal leisure it increases in function of the dose and radiation type, has given by result the obtaining of calibrated curves that are applied in the well-known technique as biological dosimetry. In this work is presented a summary of the work made in the laboratory that includes the calibrated curves for gamma radiation of 60 Cobalt and X rays of 250 k Vp, examples of presumed exposure to ionizing radiation, resolved by means of aberration analysis and the corresponding dose estimate through the equations of the respective curves and finally a comparison among the dose calculations in those people affected by the accident of Ciudad Juarez, carried out by the group of Oak Ridge, USA and those obtained in this laboratory. (Author)

  4. Astrid-2 EMMA Magnetic Calibration

    DEFF Research Database (Denmark)

    Merayo, José M.G.; Brauer, Peter; Risbo, Torben

    1998-01-01

    The Swedish micro-satellite Astrid-2 contains a tri-axial fluxgate magnetometer with the sensor co-located with a Technical University of Denmark (DTU) star camera for absolute attitude, and extended about 0.9 m on a hinged boom. The magnetometer is part of the RIT EMMA electric and magnetic fields...... experiment built as a collaboration between the DTU, Department of Automation and the Department of Plasma Physics, The Alfvenlaboratory, Royal Institute of Technology (RIT), Stockholm. The final magnetic calibration of the Astrid-2 satellite was done at the Lovoe Magnetic Observatory under the Geological...... Survey of Sweden near Stockholm on the night of May 15.-16., 1997. The magnetic calibration and the intercalibration between the star camera and the magnetic sensor was performed by measuring the Earth's magnetic field and simultaneously observing the star sky with the camera. The rotation matrix between...

  5. Bayesian calibration of the Community Land Model using surrogates

    Energy Technology Data Exchange (ETDEWEB)

    Ray, Jaideep; Hou, Zhangshuan; Huang, Maoyi; Swiler, Laura Painton

    2014-02-01

    We present results from the Bayesian calibration of hydrological parameters of the Community Land Model (CLM), which is often used in climate simulations and Earth system models. A statistical inverse problem is formulated for three hydrological parameters, conditional on observations of latent heat surface fluxes over 48 months. Our calibration method uses polynomial and Gaussian process surrogates of the CLM, and solves the parameter estimation problem using a Markov chain Monte Carlo sampler. Posterior probability densities for the parameters are developed for two sites with different soil and vegetation covers. Our method also allows us to examine the structural error in CLM under two error models. We find that surrogate models can be created for CLM in most cases. The posterior distributions are more predictive than the default parameter values in CLM. Climatologically averaging the observations does not modify the parameters' distributions significantly. The structural error model reveals a correlation time-scale which can be used to identify the physical process that could be contributing to it. While the calibrated CLM has a higher predictive skill, the calibration is under-dispersive.

  6. The ATLAS Inner Detector commissioning and calibration

    CERN Document Server

    Aad, G.; Abdallah, J.; Abdelalim, A.A.; Abdesselam, A.; Abdinov, O.; Abi, B.; Abolins, M.; Abramowicz, H.; Abreu, H.; Acharya, B.S.; Adams, D.L.; Addy, T.N.; Adelman, J.; Adorisio, C.; Adragna, P.; Adye, T.; Aefsky, S.; Aguilar-Saavedra, J.A.; Aharrouche, M.; Ahlen, S.P.; Ahles, F.; Ahmad, A.; Ahsan, M.; Aielli, G.; Akdogan, T.; Akesson, T.P.A.; Akimoto, G.; Akimov, A.V.; Aktas, A.; Alam, M.S.; Alam, M.A.; Albert, J.; Albrand, S.; Aleksa, M.; Aleksandrov, I.N.; Alexa, C.; Alexander, G.; Alexandre, G.; Alexopoulos, T.; Alhroob, M.; Aliev, M.; Alimonti, G.; Alison, J.; Aliyev, M.; Allport, P.P.; Allwood-Spiers, S.E.; Almond, J.; Aloisio, A.; Alon, R.; Alonso, A.; Alviggi, M.G.; Amako, K.; Amelung, C.; Amorim, A.; Amoros, G.; Amram, N.; Anastopoulos, C.; Andeen, T.; Anders, C.F.; Anderson, K.J.; Andreazza, A.; Andrei, V.; Anduaga, X.S.; Angerami, A.; Anghinolfi, F.; Anjos, N.; Annovi, A.; Antonaki, A.; Antonelli, M.; Antonelli, S.; Antos, J.; Antunovic, B.; Anulli, F.; Aoun, S.; Arabidze, G.; Aracena, I.; Arai, Y.; Arce, A.T.H.; Archambault, J.P.; Arfaoui, S.; Arguin, J-F.; Argyropoulos, T.; Arik, M.; Armbruster, A.J.; Arnaez, O.; Arnault, C.; Artamonov, A.; Arutinov, D.; Asai, M.; Asai, S.; Asfandiyarov, R.; Ask, S.; Asman, B.; Asner, D.; Asquith, L.; Assamagan, K.; Astbury, A.; Astvatsatourov, A.; Atoian, G.; Auerbach, B.; Augsten, K.; Aurousseau, M.; Austin, N.; Avolio, G.; Avramidou, R.; Axen, D.; Ay, C.; Azuelos, G.; Azuma, Y.; Baak, M.A.; Bach, A.M.; Bachacou, H.; Bachas, K.; Backes, M.; Badescu, E.; Bagnaia, P.; Bai, Y.; Bain, T.; Baines, J.T.; Baker, O.K.; Baker, M.D.; Baker, S.; Baltasar Dos, F.Santos Pedrosa; Banas, E.; Banerjee, P.; Banerjee, S.; Banfi, D.; Bangert, A.; Bansal, V.; Baranov, S.P.; Baranov, S.; Barashkou, A.; Barber, T.; Barberio, E.L.; Barberis, D.; Barbero, M.; Bardin, D.Y.; Barillari, T.; Barisonzi, M.; Barklow, T.; Barlow, N.; Barnett, B.M.; Barnett, R.M.; Baroncelli, A.; Barr, A.J.; Barreiro, F.; Guimara, J.Barreiro; Barrillon, P.; Bartoldus, R.; Bartsch, D.; Bates, R.L.; Batkova, L.; Batley, J.R.; Battaglia, A.; Battistin, M.; Bauer, F.; Bawa, H.S.; Bazalova, M.; Beare, B.; Beau, T.; Beauchemin, P.H.; Beccherle, R.; Bechtle, P.; Beck, G.A.; Beck, H.P.; Beckingham, M.; Becks, K.H.; Beddall, A.J.; Beddall, A.; Bednyakov, V.A.; Bee, C.; Begel, M.; Behar Harpaz, S.; Behera, P.K.; Beimforde, M.; Belanger-Champagne, C.; Bell, P.J.; Bell, W.H.; Bella, G.; Bellagamba, L.; Bellina, F.; Bellomo, M.; Belloni, A.; Belotskiy, K.; Beltramello, O.; Ben Ami, S.; Benary, O.; Benchekroun, D.; Bendel, M.; Benedict, B.H.; Benekos, N.; Benhammou, Y.; Benincasa, G.P.; Benjamin, D.P.; Benoit, M.; Bensinger, J.R.; Benslama, K.; Bentvelsen, S.; Beretta, M.; Berge, D.; Bergeaas Kuutmann, E.; Berger, N.; Berghaus, F.; Berglund, E.; Beringer, J.; Bernat, P.; Bernhard, R.; Bernius, C.; Berry, T.; Bertin, A.; Besana, M.I.; Besson, N.; Bethke, S.; Bianchi, R.M.; Bianco, M.; Biebel, O.; Biesiada, J.; Biglietti, M.; Bilokon, H.; Bindi, M.; Binet, S.; Bingul, A.; Bini, C.; Biscarat, C.; Bitenc, U.; Black, K.M.; Blair, R.E.; Blanchard, J-B.; Blanchot, G.; Blocker, C.; Blondel, A.; Blum, W.; Blumenschein, U.; Bobbink, G.J.; Bocci, A.; Boehler, M.; Boek, J.; Boelaert, N.; Boser, S.; Bogaerts, J.A.; Bohm, C.; Bohm, J.; Boisvert, V.; Bold, T.; Boldea, V.; Bondarenko, V.G.; Bondioli, M.; Boonekamp, M.; Bordoni, S.; Borer, C.; Borisov, A.; Borissov, G.; Borjanovic, I.; Borroni, S.; Bos, K.; Boscherini, D.; Bosman, M.; Boterenbrood, H.; Bouchami, J.; Boudreau, J.; Bouhova-Thacker, E.V.; Boulahouache, C.; Bourdarios, C.; Boveia, A.; Boyd, J.; Boyko, I.R.; Bozovic-Jelisavcic, I.; Bracinik, J.; Braem, A.; Branchini, P.; Brandenburg, G.W.; Brandt, A.; Brandt, G.; Brandt, O.; Bratzler, U.; Brau, B.; Brau, J.E.; Braun, H.M.; Brelier, B.; Bremer, J.; Brenner, R.; Bressler, S.; Britton, D.; Brochu, F.M.; Brock, I.; Brock, R.; Brodet, E.; Bromberg, C.; Brooijmans, G.; Brooks, W.K.; Brown, G.; Bruckman de Renstrom, P.A.; Bruncko, D.; Bruneliere, R.; Brunet, S.; Bruni, A.; Bruni, G.; Bruschi, M.; Bucci, F.; Buchanan, J.; Buchholz, P.; Buckley, A.G.; Budagov, I.A.; Budick, B.; Buscher, V.; Bugge, L.; Bulekov, O.; Bunse, M.; Buran, T.; Burckhart, H.; Burdin, S.; Burgess, T.; Burke, S.; Busato, E.; Bussey, P.; Buszello, C.P.; Butin, F.; Butler, B.; Butler, J.M.; Buttar, C.M.; Butterworth, J.M.; Byatt, T.; Caballero, J.; Urban, S.Cabrera; Caforio, D.; Cakir, O.; Calafiura, P.; Calderini, G.; Calfayan, P.; Calkins, R.; Caloba, L.P.; Calvet, D.; Camarri, P.; Cameron, D.; Campana, S.; Campanelli, M.; Canale, V.; Canelli, F.; Canepa, A.; Cantero, J.; Capasso, L.; Capeans Garrido, M.D.M.; Caprini, I.; Caprini, M.; Capua, M.; Caputo, R.; Caramarcu, C.; Cardarelli, R.; Carli, T.; Carlino, G.; Carminati, L.; Caron, B.; Caron, S.; Carrillo Montoya, G.D.; Carron Montero, S.; Carter, A.A.; Carter, J.R.; Carvalho, J.; Casadei, D.; Casado, M.P.; Cascella, M.; Castaneda Hernadez, A.M.; Castaneda-Miranda, E.; Castillo Gimenez, V.; Castro, N.F.; Cataldi, G.; Catinaccio, A.; Catmore, J.R.; Cattai, A.; Cattani, G.; Caughron, S.; Cauz, D.; Cavalleri, P.; Cavalli, D.; Cavalli-Sforza, M.; Cavasinni, V.; Ceradini, F.; Cerqueira, A.S.; Cerri, A.; Cerrito, L.; Cerutti, F.; Cetin, S.A.; Chafaq, A.; Chakraborty, D.; Chan, K.; Chapman, J.D.; Chapman, J.W.; Chareyre, E.; Charlton, D.G.; Chavda, V.; Cheatham, S.; Chekanov, S.; Chekulaev, S.V.; Chelkov, G.A.; Chen, H.; Chen, S.; Chen, X.; Cheplakov, A.; Chepurnov, V.F.; Cherkaoui El, R.Moursli; Tcherniatine, V.; Chesneanu, D.; Cheu, E.; Cheung, S.L.; Chevalier, L.; Chevallier, F.; Chiarella, V.; Chiefari, G.; Chikovani, L.; Childers, J.T.; Chilingarov, A.; Chiodini, G.; Chizhov, V.; Choudalakis, G.; Chouridou, S.; Christidi, I.A.; Christov, A.; Chromek-Burckhart, D.; Chu, M.L.; Chudoba, J.; Ciapetti, G.; Ciftci, A.K.; Ciftci, R.; Cinca, D.; Cindro, V.; Ciobotaru, M.D.; Ciocca, C.; Ciocio, A.; Cirilli, M.; Citterio, M.; Clark, A.; Clark, P.J.; Cleland, W.; Clemens, J.C.; Clement, B.; Clement, C.; Coadou, Y.; Cobal, M.; Coccaro, A.; Cochran, J.; Coggeshall, J.; Cogneras, E.; Colijn, A.P.; Collard, C.; Collins, N.J.; Collins-Tooth, C.; Collot, J.; Colon, G.; Muino, P.Conde; Coniavitis, E.; Conidi, M.C.; Consonni, M.; Constantinescu, S.; Conta, C.; Conventi, F.; Cooke, M.; Cooper, B.D.; Cooper-Sarkar, A.M.; Cooper-Smith, N.J.; Copic, K.; Cornelissen, T.; Corradi, M.; Corriveau, F.; Corso-Radu, A.; Cortes-Gonzalez, A.; Cortiana, G.; Costa, G.; Costa, M.J.; Costanzo, D.; Costin, T.; Cote, D.; Coura Torres, R.; Courneyea, L.; Cowan, G.; Cowden, C.; Cox, B.E.; Cranmer, K.; Cranshaw, J.; Cristinziani, M.; Crosetti, G.; Crupi, R.; Crepe-Renaudin, S.; Cuenca Almenar, C.; Cuhadar Donszelmann, T.; Curatolo, M.; Curtis, C.J.; Cwetanski, P.; Czyczula, Z.; D'Auria, S.; D'Onofrio, M.; D'Orazio, A.; Da Via, C.; Dabrowski, W.; Dai, T.; Dallapiccola, C.; Dam, M.; Danielsson, H.O.; Dannheim, D.; Dao, V.; Darbo, G.; Darlea, G.L.; Davey, W.; Davidek, T.; Davidson, N.; Davidson, R.; Davies, M.; Davison, A.R.; Dawson, I.; Daya, R.K.; De, K.; de Asmundis, R.; De Castro, S.; De Castro, P.E.Faria Salgado; De Cecco, S.; de Graat, J.; De Groot, N.; de Jong, P.; De Mora, L.; De Oliveira, M.Branco; De Pedis, D.; De Salvo, A.; De Sanctis, U.; De Santo, A.; De Vivie De Regie, J.B.; De Zorzi, G.; Dean, S.; Dedovich, D.V.; Degenhardt, J.; Dehchar, M.; Del Papa, C.; Del Peso, J.; Del Prete, T.; Dell'Acqua, A.; Dell'Asta, L.; Della Pietra, M.; della Volpe, D.; Delmastro, M.; Delsart, P.A.; Deluca, C.; Demers, S.; Demichev, M.; Demirkoz, B.; Deng, J.; Deng, W.; Denisov, S.P.; Derkaoui, J.E.; Derue, F.; Dervan, P.; Desch, K.; Deviveiros, P.O.; Dewhurst, A.; DeWilde, B.; Dhaliwal, S.; Dhullipudi, R.; Di Ciaccio, A.; Di Ciaccio, L.; Di Domenico, A.; Di Girolamo, A.; Di Girolamo, B.; Di Luise, S.; Di Mattia, A.; Di Nardo, R.; Di Simone, A.; Di Sipio, R.; Diaz, M.A.; Diblen, F.; Diehl, E.B.; Dietrich, J.; Dietzsch, T.A.; Diglio, S.; Dindar Yagci, K.; Dingfelder, D.J.; Dionisi, C.; Dita, P.; Dita, S.; Dittus, F.; Djama, F.; Djilkibaev, R.; Djobava, T.; Vale, M.A.B.do; Do Valle, A.Wemans; Doan, T.K.O.; Dobos, D.; Dobson, E.; Dobson, M.; Doglioni, C.; Doherty, T.; Dolejsi, J.; Dolenc, I.; Dolezal, Z.; Dolgoshein, B.A.; Dohmae, T.; Donega, M.; Donini, J.; Dopke, J.; Doria, A.; Dos Anjos, A.; Dotti, A.; Dova, M.T.; Doxiadis, A.; Doyle, A.T.; Drasal, Z.; Dris, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Dudarev, A.; Dudziak, F.; Duhrssen, M.; Duflot, L.; Dufour, M-A.; Dunford, M.; Duran Yildiz, H.; Dushkin, A.; Duxfield, R.; Dwuznik, M.; Duren, M.; Ebenstein, W.L.; Ebke, J.; Eckweiler, S.; Edmonds, K.; Edwards, C.A.; Egorov, K.; Ehrenfeld, W.; Ehrich, T.; Eifert, T.; Eigen, G.; Einsweiler, K.; Eisenhandler, E.; Ekelof, T.; El Kacimi, M.; Ellert, M.; Elles, S.; Ellinghaus, F.; Ellis, K.; Ellis, N.; Elmsheuser, J.; Elsing, M.; Emeliyanov, D.; Engelmann, R.; Engl, A.; Epp, B.; Eppig, A.; Erdmann, J.; Ereditato, A.; Eriksson, D.; Ermoline, I.; Ernst, J.; Ernst, M.; Ernwein, J.; Errede, D.; Errede, S.; Ertel, E.; Escalier, M.; Escobar, C.; Espinal Curull, X.; Esposito, B.; Etienvre, A.I.; Etzion, E.; Evans, H.; Fabbri, L.; Fabre, C.; Facius, K.; Fakhrutdinov, R.M.; Falciano, S.; Fang, Y.; Fanti, M.; Farbin, A.; Farilla, A.; Farley, J.; Farooque, T.; Farrington, S.M.; Farthouat, P.; Fassnacht, P.; Fassouliotis, D.; Fatholahzadeh, B.; Fayard, L.; Fayette, F.; Febbraro, R.; Federic, P.; Fedin, O.L.; Fedorko, W.; Feligioni, L.; Felzmann, C.U.; Feng, C.; Feng, E.J.; Fenyuk, A.B.; Ferencei, J.; Ferland, J.; Fernandes, B.; Fernando, W.; Ferrag, S.; Ferrando, J.; Ferrara, V.; Ferrari, A.; Ferrari, P.; Ferrari, R.; Ferrer, A.; Ferrer, M.L.; Ferrere, D.; Ferretti, C.; Fiascaris, M.; Fiedler, F.; Filipcic, A.; Filippas, A.; Filthaut, F.; Fincke-Keeler, M.; Fiolhais, M.C.N.; Fiorini, L.; Firan, A.; Fischer, G.; Fisher, M.J.; Flechl, M.; Fleck, I.; Fleckner, J.; Fleischmann, P.; Fleischmann, S.; Flick, T.; Flores Castillo, L.R.; Flowerdew, M.J.; Fonseca Martin, T.; Formica, A.; Forti, A.; Fortin, D.; Fournier, D.; Fowler, A.J.; Fowler, K.; Fox, H.; Francavilla, P.; Franchino, S.; Francis, D.; Franklin, M.; Franz, S.; Fraternali, M.; Fratina, S.; Freestone, J.; French, S.T.; Froeschl, R.; Froidevaux, D.; Frost, J.A.; Fukunaga, C.; Fullana Torregrosa, E.; Fuster, J.; Gabaldon, C.; Gabizon, O.; Gadfort, T.; Gadomski, S.; Gagliardi, G.; Gagnon, P.; Galea, C.; Gallas, E.J.; Gallo, V.; Gallop, B.J.; Gallus, P.; Galyaev, E.; Gan, K.K.; Gao, Y.S.; Gaponenko, A.; Garcia-Sciveres, M.; Garcia, C.; Navarro, J.E.Garcia; Gardner, R.W.; Garelli, N.; Garitaonandia, H.; Garonne, V.; Gatti, C.; Gaudio, G.; Gauzzi, P.; Gavrilenko, I.L.; Gay, C.; Gaycken, G.; Gazis, E.N.; Ge, P.; Gee, C.N.P.; Geich-Gimbel, Ch.; Gellerstedt, K.; Gemme, C.; Genest, M.H.; Gentile, S.; Georgatos, F.; George, S.; Gershon, A.; Ghazlane, H.; Ghodbane, N.; Giacobbe, B.; Giagu, S.; Giakoumopoulou, V.; Giangiobbe, V.; Gianotti, F.; Gibbard, B.; Gibson, A.; Gibson, S.M.; Gilbert, L.M.; Gilchriese, M.; Gilewsky, V.; Gingrich, D.M.; Ginzburg, J.; Giokaris, N.; Giordani, M.P.; Giordano, R.; Giorgi, F.M.; Giovannini, P.; Giraud, P.F.; Girtler, P.; Giugni, D.; Giusti, P.; Gjelsten, B.K.; Gladilin, L.K.; Glasman, C.; Glazov, A.; Glitza, K.W.; Glonti, G.L.; Godfrey, J.; Godlewski, J.; Goebel, M.; Gopfert, T.; Goeringer, C.; Gossling, C.; Gottfert, T.; Goggi, V.; Goldfarb, S.; Goldin, D.; Golling, T.; Gomes, A.; Gomez Fajardo, L.S.; Goncalo, R.; Gonella, L.; Gong, C.; Gonzalez de la Hoz, S.; Gonzalez Silva, M.L.; Gonzalez-Sevilla, S.; Goodson, J.J.; Goossens, L.; Gordon, H.A.; Gorelov, I.; Gorfine, G.; Gorini, B.; Gorini, E.; Gorisek, A.; Gornicki, E.; Gosdzik, B.; Gosselink, M.; Gostkin, M.I.; Gough Eschrich, I.; Gouighri, M.; Goujdami, D.; Goulette, M.P.; Goussiou, A.G.; Goy, C.; Grabowska-Bold, I.; Grafstrom, P.; Grahn, K-J.; Grancagnolo, S.; Grassi, V.; Gratchev, V.; Grau, N.; Gray, H.M.; Gray, J.A.; Graziani, E.; Green, B.; Greenshaw, T.; Greenwood, Z.D.; Gregor, I.M.; Grenier, P.; Griesmayer, E.; Griffiths, J.; Grigalashvili, N.; Grillo, A.A.; Grimm, K.; Grinstein, S.; Grishkevich, Y.V.; Groh, M.; Groll, M.; Gross, E.; Grosse-Knetter, J.; Groth-Jensen, J.; Grybel, K.; Guicheney, C.; Guida, A.; Guillemin, T.; Guler, H.; Gunther, J.; Guo, B.; Gusakov, Y.; Gutierrez, A.; Gutierrez, P.; Guttman, N.; Gutzwiller, O.; Guyot, C.; Gwenlan, C.; Gwilliam, C.B.; Haas, A.; Haas, S.; Haber, C.; Hadavand, H.K.; Hadley, D.R.; Haefner, P.; Hartel, R.; Hajduk, Z.; Hakobyan, H.; Haller, J.; Hamacher, K.; Hamilton, A.; Hamilton, S.; Han, L.; Hanagaki, K.; Hance, M.; Handel, C.; Hanke, P.; Hansen, J.R.; Hansen, J.B.; Hansen, J.D.; Hansen, P.H.; Hansl-Kozanecka, T.; Hansson, P.; Hara, K.; Hare, G.A.; Harenberg, T.; Harrington, R.D.; Harris, O.M.; Harrison, K.; Hartert, J.; Hartjes, F.; Harvey, A.; Hasegawa, S.; Hasegawa, Y.; Hashemi, K.; Hassani, S.; Haug, S.; Hauschild, M.; Hauser, R.; Havranek, M.; Hawkes, C.M.; Hawkings, R.J.; Hayakawa, T.; Hayward, H.S.; Haywood, S.J.; Head, S.J.; Hedberg, V.; Heelan, L.; Heim, S.; Heinemann, B.; Heisterkamp, S.; Helary, L.; Heller, M.; Hellman, S.; Helsens, C.; Hemperek, T.; Henderson, R.C.W.; Henke, M.; Henrichs, A.; Henriques Correia, A.M.; Henrot-Versille, S.; Hensel, C.; Henss, T.; Hernandez Jimenez, Y.; Hershenhorn, A.D.; Herten, G.; Hertenberger, R.; Hervas, L.; Hessey, N.P.; Higon-Rodriguez, E.; Hill, J.C.; Hiller, K.H.; Hillert, S.; Hillier, S.J.; Hinchliffe, I.; Hines, E.; Hirose, M.; Hirsch, F.; Hirschbuehl, D.; Hobbs, J.; Hod, N.; Hodgkinson, M.C.; Hodgson, P.; Hoecker, A.; Hoeferkamp, M.R.; Hoffman, J.; Hoffmann, D.; Hohlfeld, M.; Holy, T.; Holzbauer, J.L.; Homma, Y.; Horazdovsky, T.; Hori, T.; Horn, C.; Horner, S.; Horvat, S.; Hostachy, J-Y.; Hou, S.; Hoummada, A.; Howe, T.; Hrivnac, J.; Hryn'ova, T.; Hsu, P.J.; Hsu, S.C.; Huang, G.S.; Hubacek, Z.; Hubaut, F.; Huegging, F.; Huffman, T.B.; Hughes, E.W.; Hughes, G.; Hurwitz, M.; Husemann, U.; Huseynov, N.; Huston, J.; Huth, J.; Iacobucci, G.; Iakovidis, G.; Ibragimov, I.; Iconomidou-Fayard, L.; Idarraga, J.; Iengo, P.; Igonkina, O.; Ikegami, Y.; Ikeno, M.; Ilchenko, Y.; Iliadis, D.; Ince, T.; Ioannou, P.; Iodice, M.; Irles Quiles, A.; Ishikawa, A.; Ishino, M.; Ishmukhametov, R.; Isobe, T.; Issever, C.; Istin, S.; Itoh, Y.; Ivashin, A.V.; Iwasaki, H.; Izen, J.M.; Izzo, V.; Jackson, B.; Jackson, J.N.; Jackson, P.; Jaekel, M.R.; Jain, V.; Jakobs, K.; Jakobsen, S.; Jakubek, J.; Jana, D.; Jankowski, E.; Jansen, E.; Jantsch, A.; Janus, M.; Jared, R.C.; Jarlskog, G.; Jeanty, L.; Plante, I.Jen-La; Jenni, P.; Jez, P.; Jezequel, S.; Ji, W.; Jia, J.; Jiang, Y.; Jimenez Belenguer, M.; Jin, S.; Jinnouchi, O.; Joffe, D.; Johansen, M.; Johansson, K.E.; Johansson, P.; Johnert, S.; Johns, K.A.; Jon-And, K.; Jones, G.; Jones, R.W.L.; Jones, T.J.; Jorge, P.M.; Joseph, J.; Juranek, V.; Jussel, P.; Kabachenko, V.V.; Kaci, M.; Kaczmarska, A.; Kado, M.; Kagan, H.; Kagan, M.; Kaiser, S.; Kajomovitz, E.; Kalinin, S.; Kalinovskaya, L.V.; Kama, S.; Kanaya, N.; Kaneda, M.; Kantserov, V.A.; Kanzaki, J.; Kaplan, B.; Kapliy, A.; Kaplon, J.; Kar, D.; Karagounis, M.; Karagoz Unel, M.; Karnevskiy, M.; Kartvelishvili, V.; Karyukhin, A.N.; Kashif, L.; Kasmi, A.; Kass, R.D.; Kastanas, A.; Kastoryano, M.; Kataoka, M.; Kataoka, Y.; Katsoufis, E.; Katzy, J.; Kaushik, V.; Kawagoe, K.; Kawamoto, T.; Kawamura, G.; Kayl, M.S.; Kayumov, F.; Kazanin, V.A.; Kazarinov, M.Y.; Keates, J.R.; Keeler, R.; Keener, P.T.; Kehoe, R.; Keil, M.; Kekelidze, G.D.; Kelly, M.; Kenyon, M.; Kepka, O.; Kerschen, N.; Kersevan, B.P.; Kersten, S.; Kessoku, K.; Khakzad, M.; Khalil-zada, F.; Khandanyan, H.; Khanov, A.; Kharchenko, D.; Khodinov, A.; Khomich, A.; Khoriauli, G.; Khovanskiy, N.; Khovanskiy, V.; Khramov, E.; Khubua, J.; Kim, H.; Kim, M.S.; Kim, P.C.; Kim, S.H.; Kind, O.; Kind, P.; King, B.T.; Kirk, J.; Kirsch, G.P.; Kirsch, L.E.; Kiryunin, A.E.; Kisielewska, D.; Kittelmann, T.; Kiyamura, H.; Kladiva, E.; Klein, M.; Klein, U.; Kleinknecht, K.; Klemetti, M.; Klier, A.; Klimentov, A.; Klingenberg, R.; Klinkby, E.B.; Klioutchnikova, T.; Klok, P.F.; Klous, S.; Kluge, E.E.; Kluge, T.; Kluit, P.; Klute, M.; Kluth, S.; Knecht, N.S.; Kneringer, E.; Ko, B.R.; Kobayashi, T.; Kobel, M.; Koblitz, B.; Kocian, M.; Kocnar, A.; Kodys, P.; Koneke, K.; Konig, A.C.; Koenig, S.; Kopke, L.; Koetsveld, F.; Koevesarki, P.; Koffas, T.; Koffeman, E.; Kohn, F.; Kohout, Z.; Kohriki, T.; Kolanoski, H.; Kolesnikov, V.; Koletsou, I.; Koll, J.; Kollar, D.; Kolos, S.; Kolya, S.D.; Komar, A.A.; Komaragiri, J.R.; Kondo, T.; Kono, T.; Konoplich, R.; Konovalov, S.P.; Konstantinidis, N.; Koperny, S.; Korcyl, K.; Kordas, K.; Korn, A.; Korolkov, I.; Korolkova, E.V.; Korotkov, V.A.; Kortner, O.; Kostka, P.; Kostyukhin, V.V.; Kotov, S.; Kotov, V.M.; Kotov, K.Y.; Kourkoumelis, C.; Koutsman, A.; Kowalewski, R.; Kowalski, H.; Kowalski, T.Z.; Kozanecki, W.; Kozhin, A.S.; Kral, V.; Kramarenko, V.A.; Kramberger, G.; Krasny, M.W.; Krasznahorkay, A.; Kraus, J.; Kreisel, A.; Krejci, F.; Kretzschmar, J.; Krieger, N.; Krieger, P.; Kroeninger, K.; Kroha, H.; Kroll, J.; Kroseberg, J.; Krstic, J.; Kruchonak, U.; Kruger, H.; Krumshteyn, Z.V.; Kubota, T.; Kuehn, S.; Kugel, A.; Kuhl, T.; Kuhn, D.; Kukhtin, V.; Kulchitsky, Y.; Kuleshov, S.; Kummer, C.; Kuna, M.; Kunkle, J.; Kupco, A.; Kurashige, H.; Kurata, M.; Kurchaninov, L.L.; Kurochkin, Y.A.; Kus, V.; Kwee, R.; La Rosa, A.; La Rotonda, L.; Labbe, J.; Lacasta, C.; Lacava, F.; Lacker, H.; Lacour, D.; Lacuesta, V.R.; Ladygin, E.; Lafaye, R.; Laforge, B.; Lagouri, T.; Lai, S.; Lamanna, M.; Lampen, C.L.; Lampl, W.; Lancon, E.; Landgraf, U.; Landon, M.P.J.; Lane, J.L.; Lankford, A.J.; Lanni, F.; Lantzsch, K.; Lanza, A.; Laplace, S.; Lapoire, C.; Laporte, J.F.; Lari, T.; Larner, A.; Lassnig, M.; Laurelli, P.; Lavrijsen, W.; Laycock, P.; Lazarev, A.B.; Lazzaro, A.; Le Dortz, O.; Le Guirriec, E.; Le Menedeu, E.; Le Vine, M.; Lebedev, A.; Lebel, C.; LeCompte, T.; Ledroit-Guillon, F.; Lee, H.; Lee, J.S.H.; Lee, S.C.; Lefebvre, M.; Legendre, M.; LeGeyt, B.C.; Legger, F.; Leggett, C.; Lehmacher, M.; Lehmann Miotto, G.; Lei, X.; Leitner, R.; Lellouch, D.; Lellouch, J.; Lendermann, V.; Leney, K.J.C.; Lenz, T.; Lenzen, G.; Lenzi, B.; Leonhardt, K.; Leroy, C.; Lessard, J-R.; Lester, C.G.; Leung Fook, A.Cheong; Leveque, J.; Levin, D.; Levinson, L.J.; Leyton, M.; Li, H.; Li, X.; Liang, Z.; Liang, Z.; Liberti, B.; Lichard, P.; Lichtnecker, M.; Lie, K.; Liebig, W.; Lilley, J.N.; Limosani, A.; Limper, M.; Lin, S.C.; Linnemann, J.T.; Lipeles, E.; Lipinsky, L.; Lipniacka, A.; Liss, T.M.; Lissauer, D.; Lister, A.; Litke, A.M.; Liu, C.; Liu, D.; Liu, H.; Liu, J.B.; Liu, M.; Liu, T.; Liu, Y.; Livan, M.; Lleres, A.; Lloyd, S.L.; Lobodzinska, E.; Loch, P.; Lockman, W.S.; Lockwitz, S.; Loddenkoetter, T.; Loebinger, F.K.; Loginov, A.; Loh, C.W.; Lohse, T.; Lohwasser, K.; Lokajicek, M.; Long, R.E.; Lopes, L.; Lopez Mateos, D.; Losada, M.; Loscutoff, P.; Lou, X.; Lounis, A.; Loureiro, K.F.; Lovas, L.; Love, J.; Love, P.A.; Lowe, A.J.; Lu, F.; Lubatti, H.J.; Luci, C.; Lucotte, A.; Ludwig, A.; Ludwig, D.; Ludwig, I.; Luehring, F.; Luisa, L.; Lumb, D.; Luminari, L.; Lund, E.; Lund-Jensen, B.; Lundberg, B.; Lundberg, J.; Lundquist, J.; Lynn, D.; Lys, J.; Lytken, E.; Ma, H.; Ma, L.L.; Macana Goia, J.A.; Maccarrone, G.; Macchiolo, A.; Macek, B.; Machado Miguens, J.; Mackeprang, R.; Madaras, R.J.; Mader, W.F.; Maenner, R.; Maeno, T.; Mattig, P.; Mattig, S.; Magalhaes Martins, P.J.; Magradze, E.; Mahalalel, Y.; Mahboubi, K.; Mahmood, A.; Maiani, C.; Maidantchik, C.; Maio, A.; Majewski, S.; Makida, Y.; Makouski, M.; Makovec, N.; Malecki, Pa.; Malecki, P.; Maleev, V.P.; Malek, F.; Mallik, U.; Malon, D.; Maltezos, S.; Malyshev, V.; Malyukov, S.; Mambelli, M.; Mameghani, R.; Mamuzic, J.; Mandelli, L.; Mandic, I.; Mandrysch, R.; Maneira, J.; Mangeard, P.S.; Manjavidze, I.D.; Manning, P.M.; Manousakis-Katsikakis, A.; Mansoulie, B.; Mapelli, A.; Mapelli, L.; March, L.; Marchand, J.F.; Marchese, F.; Marchiori, G.; Marcisovsky, M.; Marino, C.P.; Marroquim, F.; Marshall, Z.; Marti-Garcia, S.; Martin, A.J.; Martin, A.J.; Martin, B.; Martin, B.; Martin, F.F.; Martin, J.P.; Martin, T.A.; Dit Latour, B.Martin; Martinez, M.; Martinez Outschoorn, V.; Martini, A.; Martyniuk, A.C.; Marzano, F.; Marzin, A.; Masetti, L.; Mashimo, T.; Mashinistov, R.; Masik, J.; Maslennikov, A.L.; Massa, I.; Massol, N.; Mastroberardino, A.; Masubuchi, T.; Matsunaga, H.; Matsushita, T.; Mattravers, C.; Maxfield, S.J.; Mayne, A.; Mazini, R.; Mazur, M.; Mazzanti, M.; Mc Donald, J.; Mc Kee, S.P.; McCarn, A.; McCarthy, R.L.; McCubbin, N.A.; McFarlane, K.W.; McGlone, H.; Mchedlidze, G.; McMahon, S.J.; McPherson, R.A.; Meade, A.; Mechnich, J.; Mechtel, M.; Medinnis, M.; Meera-Lebbai, R.; Meguro, T.M.; Mehlhase, S.; Mehta, A.; Meier, K.; Meirose, B.; Melachrinos, C.; Mellado Garcia, B.R.; Mendoza Navas, L.; Meng, Z.; Menke, S.; Meoni, E.; Mermod, P.; Merola, L.; Meroni, C.; Merritt, F.S.; Messina, A.M.; Metcalfe, J.; Mete, A.S.; Meyer, J-P.; Meyer, J.; Meyer, J.; Meyer, T.C.; Meyer, W.T.; Miao, J.; Michal, S.; Micu, L.; Middleton, R.P.; Migas, S.; Mijovic, L.; Mikenberg, G.; Mikestikova, M.; Mikuz, M.; Miller, D.W.; Mills, W.J.; Mills, C.M.; Milov, A.; Milstead, D.A.; Milstein, D.; Minaenko, A.A.; Minano, M.; Minashvili, I.A.; Mincer, A.I.; Mindur, B.; Mineev, M.; Ming, Y.; Mir, L.M.; Mirabelli, G.; Misawa, S.; Miscetti, S.; Misiejuk, A.; Mitrevski, J.; Mitsou, V.A.; Miyagawa, P.S.; Mjornmark, J.U.; Mladenov, D.; Moa, T.; Moed, S.; Moeller, V.; Monig, K.; Moser, N.; Mohr, W.; Mohrdieck-Mock, S.; Moles-Valls, R.; Molina-Perez, J.; Monk, J.; Monnier, E.; Montesano, S.; Monticelli, F.; Moore, R.W.; Mora Herrera, C.; Moraes, A.; Morais, A.; Morel, J.; Morello, G.; Moreno, D.; Llacer, M.Moreno; Morettini, P.; Morii, M.; Morley, A.K.; Mornacchi, G.; Morozov, S.V.; Morris, J.D.; Moser, H.G.; Mosidze, M.; Moss, J.; Mount, R.; Mountricha, E.; Mouraviev, S.V.; Moyse, E.J.W.; Mudrinic, M.; Mueller, F.; Mueller, J.; Mueller, K.; Muller, T.A.; Muenstermann, D.; Muir, A.; Munwes, Y.; Murillo Garcia, R.; Murray, W.J.; Mussche, I.; Musto, E.; Myagkov, A.G.; Myska, M.; Nadal, J.; Nagai, K.; Nagano, K.; Nagasaka, Y.; Nairz, A.M.; Nakamura, K.; Nakano, I.; Nakatsuka, H.; Nanava, G.; Napier, A.; Nash, M.; Nation, N.R.; Nattermann, T.; Naumann, T.; Navarro, G.; Nderitu, S.K.; Neal, H.A.; Nebot, E.; Nechaeva, P.; Negri, A.; Negri, G.; Nelson, A.; Nelson, T.K.; Nemecek, S.; Nemethy, P.; Nepomuceno, A.A.; Nessi, M.; Neubauer, M.S.; Neusiedl, A.; Neves, R.N.; Nevski, P.; Newcomer, F.M.; Nickerson, R.B.; Nicolaidou, R.; Nicolas, L.; Nicoletti, G.; Nicquevert, B.; Niedercorn, F.; Nielsen, J.; Nikiforov, A.; Nikolaev, K.; Nikolic-Audit, I.; Nikolopoulos, K.; Nilsen, H.; Nilsson, P.; Nisati, A.; Nishiyama, T.; Nisius, R.; Nodulman, L.; Nomachi, M.; Nomidis, I.; Nordberg, M.; Nordkvist, B.; Notz, D.; Novakova, J.; Nozaki, M.; Nozicka, M.; Nugent, I.M.; Nuncio-Quiroz, A.E.; Nunes Hanninger, G.; Nunnemann, T.; Nurse, E.; O'Neil, D.C.; O'Shea, V.; Oakham, F.G.; Oberlack, H.; Ochi, A.; Oda, S.; Odaka, S.; Odier, J.; Ogren, H.; Oh, A.; Oh, S.H.; Ohm, C.C.; Ohshima, T.; Ohshita, H.; Ohsugi, T.; Okada, S.; Okawa, H.; Okumura, Y.; Okuyama, T.; Olchevski, A.G.; Oliveira, M.; Oliveira Damazio, D.; Oliver, J.; Oliver Garcia, E.; Olivito, D.; Olszewski, A.; Olszowska, J.; Omachi, C.; Onofre, A.; Onyisi, P.U.E.; Oram, C.J.; Oreglia, M.J.; Oren, Y.; Orestano, D.; Orlov, I.; Oropeza Barrera, C.; Orr, R.S.; Ortega, E.O.; Osculati, B.; Ospanov, R.; Osuna, C.; Ottersbach, J.P.; Ould-Saada, F.; Ouraou, A.; Ouyang, Q.; Owen, M.; Owen, S.; Oyarzun, A.; Ozcan, V.E.; Ozone, K.; Ozturk, N.; Pacheco Pages, A.; Padilla Aranda, C.; Paganis, E.; Pahl, C.; Paige, F.; Pajchel, K.; Palestini, S.; Pallin, D.; Palma, A.; Palmer, J.D.; Pan, Y.B.; Panagiotopoulou, E.; Panes, B.; Panikashvili, N.; Panitkin, S.; Pantea, D.; Panuskova, M.; Paolone, V.; Papadopoulou, Th.D.; Park, S.J.; Park, W.; Parker, M.A.; Parker, S.I.; Parodi, F.; Parsons, J.A.; Parzefall, U.; Pasqualucci, E.; Passeri, A.; Pastore, F.; Pastore, Fr.; Pasztor, G.; Pataraia, S.; Pater, J.R.; Patricelli, S.; Patwa, A.; Pauly, T.; Peak, L.S.; Pecsy, M.; Pedraza Morales, M.I.; Peleganchuk, S.V.; Peng, H.; Penson, A.; Penwell, J.; Perantoni, M.; Perez, K.; Perez Codina, E.; Perez Garcia-Estan, M.T.; Perez Reale, V.; Perini, L.; Pernegger, H.; Perrino, R.; Persembe, S.; Perus, P.; Peshekhonov, V.D.; Petersen, B.A.; Petersen, T.C.; Petit, E.; Petridou, C.; Petrolo, E.; Petrucci, F.; Petschull, D.; Petteni, M.; Pezoa, R.; Phan, A.; Phillips, A.W.; Piacquadio, G.; Piccinini, M.; Piegaia, R.; Pilcher, J.E.; Pilkington, A.D.; Pina, J.; Pinamonti, M.; Pinfold, J.L.; Pinto, B.; Pizio, C.; Placakyte, R.; Plamondon, M.; Pleier, M.A.; Poblaguev, A.; Poddar, S.; Podlyski, F.; Poffenberger, P.; Poggioli, L.; Pohl, M.; Polci, F.; Polesello, G.; Policicchio, A.; Polini, A.; Poll, J.; Polychronakos, V.; Pomeroy, D.; Pommes, K.; Pontecorvo, L.; Pope, B.G.; Popovic, D.S.; Poppleton, A.; Popule, J.; Portell Bueso, X.; Porter, R.; Pospelov, G.E.; Pospisil, S.; Potekhin, M.; Potrap, I.N.; Potter, C.J.; Potter, C.T.; Potter, K.P.; Poulard, G.; Poveda, J.; Prabhu, R.; Pralavorio, P.; Prasad, S.; Pravahan, R.; Pribyl, L.; Price, D.; Price, L.E.; Prichard, P.M.; Prieur, D.; Primavera, M.; Prokofiev, K.; Prokoshin, F.; Protopopescu, S.; Proudfoot, J.; Prudent, X.; Przysiezniak, H.; Psoroulas, S.; Ptacek, E.; Puigdengoles, C.; Purdham, J.; Purohit, M.; Puzo, P.; Pylypchenko, Y.; Qi, M.; Qian, J.; Qian, W.; Qin, Z.; Quadt, A.; Quarrie, D.R.; Quayle, W.B.; Quinonez, F.; Raas, M.; Radeka, V.; Radescu, V.; Radics, B.; Rador, T.; Ragusa, F.; Rahal, G.; Rahimi, A.M.; Rajagopalan, S.; Rammensee, M.; Rammes, M.; Rauscher, F.; Rauter, E.; Raymond, M.; Read, A.L.; Rebuzzi, D.M.; Redelbach, A.; Redlinger, G.; Reece, R.; Reeves, K.; Reinherz-Aronis, E.; Reinsch, A.; Reisinger, I.; Reljic, D.; Rembser, C.; Ren, Z.L.; Renkel, P.; Rescia, S.; Rescigno, M.; Resconi, S.; Resende, B.; Reznicek, P.; Rezvani, R.; Richards, A.; Richards, R.A.; Richter, R.; Richter-Was, E.; Ridel, M.; Rijpstra, M.; Rijssenbeek, M.; Rimoldi, A.; Rinaldi, L.; Rios, R.R.; Riu, I.; Rizatdinova, F.; Rizvi, E.; Roa Romero, D.A.; Robertson, S.H.; Robichaud-Veronneau, A.; Robinson, D.; Robinson, J.E.M.; Robinson, M.; Robson, A.; Rocha de Lima, J.G.; Roda, C.; Roda Dos, D.Santos; Rodriguez, D.; Rodriguez Garcia, Y.; Roe, S.; Rohne, O.; Rojo, V.; Rolli, S.; Romaniouk, A.; Romanov, V.M.; Romeo, G.; Romero Maltrana, D.; Roos, L.; Ros, E.; Rosati, S.; Rosenbaum, G.A.; Rosselet, L.; Rossetti, V.; Rossi, L.P.; Rotaru, M.; Rothberg, J.; Rousseau, D.; Royon, C.R.; Rozanov, A.; Rozen, Y.; Ruan, X.; Ruckert, B.; Ruckstuhl, N.; Rud, V.I.; Rudolph, G.; Ruhr, F.; Ruggieri, F.; Ruiz-Martinez, A.; Rumyantsev, L.; Rurikova, Z.; Rusakovich, N.A.; Rutherfoord, J.P.; Ruwiedel, C.; Ruzicka, P.; Ryabov, Y.F.; Ryan, P.; Rybkin, G.; Rzaeva, S.; Saavedra, A.F.; Sadrozinski, H.F-W.; Sadykov, R.; Safai Tehrani, F.; Sakamoto, H.; Salamanna, G.; Salamon, A.; Saleem, M.S.; Salihagic, D.; Salnikov, A.; Salt, J.; Salvachua Ferrando, B.M.; Salvatore, D.; Salvatore, F.; Salvucci, A.; Salzburger, A.; Sampsonidis, D.; Samset, B.H.; Sanchis Lozano, M.A.; Sandaker, H.; Sander, H.G.; Sanders, M.P.; Sandhoff, M.; Sandhu, P.; Sandstroem, R.; Sandvoss, S.; Sankey, D.P.C.; Sanny, B.; Sansoni, A.; Santamarina Rios, C.; Santoni, C.; Santonico, R.; Saraiva, J.G.; Sarangi, T.; Sarkisyan-Grinbaum, E.; Sarri, F.; Sasaki, O.; Sasao, N.; Satsounkevitch, I.; Sauvage, G.; Savard, P.; Savine, A.Y.; Savinov, V.; Sawyer, L.; Saxon, D.H.; Says, L.P.; Sbarra, C.; Sbrizzi, A.; Scannicchio, D.A.; Schaarschmidt, J.; Schacht, P.; Schafer, U.; Schaetzel, S.; Schaffer, A.C.; Schaile, D.; Schamberger, R.D.; Schamov, A.G.; Scharf, V.; Schegelsky, V.A.; Scheirich, D.; Schernau, M.; Scherzer, M.I.; Schiavi, C.; Schieck, J.; Schioppa, M.; Schlenker, S.; Schmidt, E.S.; Schmieden, K.; Schmitt, C.; Schmitz, M.; Schonig, A.; Schott, M.; Schouten, D.; Schovancova, J.; Schram, M.; Schreiner, A.; Schroeder, C.; Schroer, N.; Schroers, M.; Schultes, J.; Schultz-Coulon, H.C.; Schumacher, J.W.; Schumacher, M.; Schumm, B.A.; Schune, Ph.; Schwanenberger, C.; Schwartzman, A.; Schwemling, Ph.; Schwienhorst, R.; Schwierz, R.; Schwindling, J.; Scott, W.G.; Searcy, J.; Sedykh, E.; Segura, E.; Seidel, S.C.; Seiden, A.; Seifert, F.; Seixas, J.M.; Sekhniaidze, G.; Seliverstov, D.M.; Sellden, B.; Semprini-Cesari, N.; Serfon, C.; Serin, L.; Seuster, R.; Severini, H.; Sevior, M.E.; Sfyrla, A.; Shabalina, E.; Shamim, M.; Shan, L.Y.; Shank, J.T.; Shao, Q.T.; Shapiro, M.; Shatalov, P.B.; Shaw, K.; Sherman, D.; Sherwood, P.; Shibata, A.; Shimojima, M.; Shin, T.; Shmeleva, A.; Shochet, M.J.; Shupe, M.A.; Sicho, P.; Sidoti, A.; Siegert, F.; Siegrist, J.; Sijacki, Dj.; Silbert, O.; Silva, J.; Silver, Y.; Silverstein, D.; Silverstein, S.B.; Simak, V.; Simic, Lj.; Simion, S.; Simmons, B.; Simonyan, M.; Sinervo, P.; Sinev, N.B.; Sipica, V.; Siragusa, G.; Sisakyan, A.N.; Sivoklokov, S.Yu.; Sjoelin, J.; Sjursen, T.B.; Skovpen, K.; Skubic, P.; Slater, M.; Slavicek, T.; Sliwa, K.; Sloper, J.; Sluka, T.; Smakhtin, V.; Smirnov, S.Yu.; Smirnov, Y.; Smirnova, L.N.; Smirnova, O.; Smith, B.C.; Smith, D.; Smith, K.M.; Smizanska, M.; Smolek, K.; Snesarev, A.A.; Snow, S.W.; Snow, J.; Snuverink, J.; Snyder, S.; Soares, M.; Sobie, R.; Sodomka, J.; Soffer, A.; Solans, C.A.; Solar, M.; Solc, J.; Solfaroli Camillocci, E.; Solodkov, A.A.; Solovyanov, O.V.; Soluk, R.; Sondericker, J.; Sopko, V.; Sopko, B.; Sosebee, M.; Soukharev, A.; Spagnolo, S.; Spano, F.; Spencer, E.; Spighi, R.; Spigo, G.; Spila, F.; Spiwoks, R.; Spousta, M.; Spreitzer, T.; Spurlock, B.; Denis, R.D.St.; Stahl, T.; Stahlman, J.; Stamen, R.; Stancu, S.N.; Stanecka, E.; Stanek, R.W.; Stanescu, C.; Stapnes, S.; Starchenko, E.A.; Stark, J.; Staroba, P.; Starovoitov, P.; Stastny, J.; Stavina, P.; Steele, G.; Steinbach, P.; Steinberg, P.; Stekl, I.; Stelzer, B.; Stelzer, H.J.; Stelzer-Chilton, O.; Stenzel, H.; Stevenson, K.; Stewart, G.; Stockton, M.C.; Stoerig, K.; Stoicea, G.; Stonjek, S.; Strachota, P.; Stradling, A.R.; Straessner, A.; Strandberg, J.; Strandberg, S.; Strandlie, A.; Strauss, M.; Strizenec, P.; Strohmer, R.; Strom, D.M.; Stroynowski, R.; Strube, J.; Stugu, B.; Sturm, P.; Soh, D.A.; Su, D.; Sugaya, Y.; Sugimoto, T.; Suhr, C.; Suk, M.; Sulin, V.V.; Sultansoy, S.; Sumida, T.; Sun, X.H.; Sundermann, J.E.; Suruliz, K.; Sushkov, S.; Susinno, G.; Sutton, M.R.; Suzuki, T.; Suzuki, Y.; Sykora, I.; Sykora, T.; Szymocha, T.; Sanchez, J.; Ta, D.; Tackmann, K.; Taffard, A.; Tafirout, R.; Taga, A.; Takahashi, Y.; Takai, H.; Takashima, R.; Takeda, H.; Takeshita, T.; Talby, M.; Talyshev, A.; Tamsett, M.C.; Tanaka, J.; Tanaka, R.; Tanaka, S.; Tanaka, S.; Tapprogge, S.; Tardif, D.; Tarem, S.; Tarrade, F.; Tartarelli, G.F.; Tas, P.; Tasevsky, M.; Tassi, E.; Tatarkhanov, M.; Taylor, C.; Taylor, F.E.; Taylor, G.N.; Taylor, R.P.; Taylor, W.; Teixeira-Dias, P.; Ten Kate, H.; Teng, P.K.; Tennenbaum-Katan, Y.D.; Terada, S.; Terashi, K.; Terron, J.; Terwort, M.; Testa, M.; Teuscher, R.J.; Therhaag, J.; Thioye, M.; Thoma, S.; Thomas, J.P.; Thompson, E.N.; Thompson, P.D.; Thompson, P.D.; Thompson, R.J.; Thompson, A.S.; Thomson, E.; Thun, R.P.; Tic, T.; Tikhomirov, V.O.; Tikhonov, Y.A.; Tipton, P.; Tique Aires, F.J.Viegas; Tisserant, S.; Toczek, B.; Todorov, T.; Todorova-Nova, S.; Toggerson, B.; Tojo, J.; Tokar, S.; Tokushuku, K.; Tollefson, K.; Tomasek, L.; Tomasek, M.; Tomoto, M.; Tompkins, L.; Toms, K.; Tonoyan, A.; Topfel, C.; Topilin, N.D.; Torchiani, I.; Torrence, E.; Pastor, E.Torro; Toth, J.; Touchard, F.; Tovey, D.R.; Trefzger, T.; Tremblet, L.; Tricoli, A.; Trigger, I.M.; Trincaz-Duvoid, S.; Trinh, T.N.; Tripiana, M.F.; Triplett, N.; Trischuk, W.; Trivedi, A.; Trocme, B.; Troncon, C.; Trzupek, A.; Tsarouchas, C.; Tseng, J.C-L.; Tsiakiris, M.; Tsiareshka, P.V.; Tsionou, D.; Tsipolitis, G.; Tsiskaridze, V.; Tskhadadze, E.G.; Tsukerman, I.I.; Tsulaia, V.; Tsung, J.W.; Tsuno, S.; Tsybychev, D.; Tuggle, J.M.; Turecek, D.; Turk Cakir, I.; Turlay, E.; Tuts, P.M.; Twomey, M.S.; Tylmad, M.; Tyndel, M.; Uchida, K.; Ueda, I.; Ueno, R.; Ugland, M.; Uhlenbrock, M.; Uhrmacher, M.; Ukegawa, F.; Unal, G.; Undrus, A.; Unel, G.; Unno, Y.; Urbaniec, D.; Urkovsky, E.; Urquijo, P.; Urrejola, P.; Usai, G.; Uslenghi, M.; Vacavant, L.; Vacek, V.; Vachon, B.; Vahsen, S.; Valente, P.; Valentinetti, S.; Valkar, S.; Valladolid Gallego, E.; Vallecorsa, S.; Valls Ferrer, J.A.; Van Berg, R.; van der Graaf, H.; van der Kraaij, E.; van der Poel, E.; van der Ster, D.; van Eldik, N.; van Gemmeren, P.; van Kesteren, Z.; van Vulpen, I.; Vandelli, W.; Vaniachine, A.; Vankov, P.; Vannucci, F.; Vari, R.; Varnes, E.W.; Varouchas, D.; Vartapetian, A.; Varvell, K.E.; Vasilyeva, L.; Vassilakopoulos, V.I.; Vazeille, F.; Vellidis, C.; Veloso, F.; Veneziano, S.; Ventura, A.; Ventura, D.; Venturi, M.; Venturi, N.; Vercesi, V.; Verducci, M.; Verkerke, W.; Vermeulen, J.C.; Vetterli, M.C.; Vichou, I.; Vickey, T.; Viehhauser, G.H.A.; Villa, M.; Villani, E.G.; Villaplana Perez, M.; Vilucchi, E.; Vincter, M.G.; Vinek, E.; Vinogradov, V.B.; Viret, S.; Virzi, J.; Vitale, A.; Vitells, O.; Vivarelli, I.; Vives Vaque, F.; Vlachos, S.; Vlasak, M.; Vlasov, N.; Vogel, A.; Vokac, P.; Volpi, M.; von der Schmitt, H.; von Loeben, J.; von Radziewski, H.; von Toerne, E.; Vorobel, V.; Vorwerk, V.; Vos, M.; Voss, R.; Voss, T.T.; Vossebeld, J.H.; Vranjes, N.; Vranjes Milosavljevic, M.; Vrba, V.; Vreeswijk, M.; Vu Anh, T.; Vudragovic, D.; Vuillermet, R.; Vukotic, I.; Wagner, P.; Walbersloh, J.; Walder, J.; Walker, R.; Walkowiak, W.; Wall, R.; Wang, C.; Wang, H.; Wang, J.; Wang, S.M.; Warburton, A.; Ward, C.P.; Warsinsky, M.; Wastie, R.; Watkins, P.M.; Watson, A.T.; Watson, M.F.; Watts, G.; Watts, S.; Waugh, A.T.; Waugh, B.M.; Weber, M.D.; Weber, M.; Weber, M.S.; Weber, P.; Weidberg, A.R.; Weingarten, J.; Weiser, C.; Wellenstein, H.; Wells, P.S.; Wen, M.; Wenaus, T.; Wendler, S.; Wengler, T.; Wenig, S.; Wermes, N.; Werner, M.; Werner, P.; Werth, M.; Werthenbach, U.; Wessels, M.; Whalen, K.; White, A.; White, M.J.; White, S.; Whitehead, S.R.; Whiteson, D.; Whittington, D.; Wicek, F.; Wicke, D.; Wickens, F.J.; Wiedenmann, W.; Wielers, M.; Wienemann, P.; Wiglesworth, C.; Wiik, L.A.M.; Wildauer, A.; Wildt, M.A.; Wilkens, H.G.; Williams, E.; Williams, H.H.; Willocq, S.; Wilson, J.A.; Wilson, M.G.; Wilson, A.; Wingerter-Seez, I.; Winklmeier, F.; Wittgen, M.; Wolter, M.W.; Wolters, H.; Wosiek, B.K.; Wotschack, J.; Woudstra, M.J.; Wraight, K.; Wright, C.; Wright, D.; Wrona, B.; Wu, S.L.; Wu, X.; Wulf, E.; Wynne, B.M.; Xaplanteris, L.; Xella, S.; Xie, S.; Xu, D.; Xu, N.; Yamada, M.; Yamamoto, A.; Yamamoto, K.; Yamamoto, S.; Yamamura, T.; Yamaoka, J.; Yamazaki, T.; Yamazaki, Y.; Yan, Z.; Yang, H.; Yang, U.K.; Yang, Z.; Yao, W-M.; Yao, Y.; Yasu, Y.; Ye, J.; Ye, S.; Yilmaz, M.; Yoosoofmiya, R.; Yorita, K.; Yoshida, R.; Young, C.; Youssef, S.P.; Yu, D.; Yu, J.; Yuan, L.; Yurkewicz, A.; Zaidan, R.; Zaitsev, A.M.; Zajacova, Z.; Zambrano, V.; Zanello, L.; Zaytsev, A.; Zeitnitz, C.; Zeller, M.; Zemla, A.; Zendler, C.; Zenin, O.; Zenis, T.; Zenonos, Z.; Zenz, S.; Zerwas, D.; della Porta, G.Zevi; Zhan, Z.; Zhang, H.; Zhang, J.; Zhang, Q.; Zhang, X.; Zhao, L.; Zhao, T.; Zhao, Z.; Zhemchugov, A.; Zhong, J.; Zhou, B.; Zhou, N.; Zhou, Y.; Zhu, C.G.; Zhu, H.; Zhu, Y.; Zhuang, X.; Zhuravlov, V.; Zimmermann, R.; Zimmermann, S.; Zimmermann, S.; Ziolkowski, M.; Zivkovic, L.; Zobernig, G.; Zoccoli, A.; zur Nedden, M.

    2010-01-01

    The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data- taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and in-situ calibrations are described. Tracking performance has been measured with 7.6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energy-loss calibration and transition radiation turn-on measurements have been performed. Different alignment techniques have been used to reconstruct the detector geometry. After the initial alignment, a transverse impact parameter resolution of 22.1+/-0.9 {\\mu}m and a relative momentum resolution {\\sigma}p/p = (4.83+/-0.16)...

  7. On-line monitoring for calibration reduction

    International Nuclear Information System (INIS)

    Hoffmann, Mario; Gran, Frauke Schmitt; Thunem, Harald P-J.

    2004-04-01

    On-Line Monitoring (OLM) of a channel's calibration state evaluates instrument channel performance by assessing its consistency with other plant indications. Industry and experience at several plants has shown this overall approach to be very effective in identifying instrument channels that are exhibiting degrading or inconsistent performance characteristics. The Halden Reactor Project has developed the signal validation system PEANO, which can be used to assist with the tasks of OLM. To further enhance the PEANO System for use as a calibration reduction tool, the following two additional modules have been developed; HRP Prox, which performs pre-processing and statistical analysis of signal data, Batch Monitoring Module (BMM), which is an off-line batch monitoring and reporting suite. The purpose and functionality of the HRP Prox and BMM modules are discussed in this report, as well as the improvements made to the PEANO Server to support these new modules. The Halden Reactor Project has established a Halden On-Line Monitoring User Group (HOLMUG), devoted to the discussion and implementation of on-line monitoring techniques in power plants. It is formed by utilities, vendors, regulatory bodies and research institutes that meet regularly to discuss implementation aspects of on-line monitoring, technical specification changes, cost-benefit analysis and regulatory issues. (Author)

  8. Ray-based calibration for the micro optical metrology system

    Science.gov (United States)

    Yin, Yongkai; Wang, Meng; Li, Ameng; Liu, Xiaoli; Peng, Xiang

    2014-05-01

    Fringe projection 3D microscopy (FP-3DM) plays an important role in micro-machining and micro-fabrication. FP-3DM may be realized with quite different arrangements and principles, which make people confused to select an appropriate one for their specific application. This paper introduces the ray-based general imaging model to describe the FP-3DM, which has the potential to get a unified expression for different system arrangements. Meanwhile the dedicated calibration procedure is also presented to realize quantitative 3D imaging. The validity and accuracy of proposed calibration approach is demonstrated with experiments.

  9. Transfer of calibration between length and sweet-spot perception by dynamic touch

    NARCIS (Netherlands)

    Withagen, Rob; Michaels, Claire F.

    2007-01-01

    Calibration is the process that scales perceptual judgment or action to information. An earlier study (Withagen & Michaels, 2004) suggested that perceptual calibration is specific to information-to-perception relations. In the present experiments, the authors tested this hypothesis by asking whether

  10. Calibration Report for the WRAP Facility Gamma Energy Analysis System [104-ND-06-102A

    International Nuclear Information System (INIS)

    WILLS, C.E.

    1999-01-01

    This calibration report outlines the specific items included in the TRU Control of Measuring Testing and Data Collection Equipment. This report also shows the development of the calibration errors which are to be folded into the Total Measurement Uncertainty (TMU) document

  11. Calibration of thermometers in the range from 4K to 40K

    International Nuclear Information System (INIS)

    Cruz, M.E. de la; Sereni, Julian; Salva, Horacio.

    1977-06-01

    Carbon and Germanium resistors have been calibrated against a standard in the temperature range from 4K to 40K. From the data, values of temperature are obtained with 0,1% error (std deviation). These calibrations have been also checked against specific heat measurements. (author) [es

  12. Novel real-time alignment and calibration of the LHCb detector in Run II

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Z., E-mail: zhirui.xu@epfl.ch; Tobin, M.

    2016-07-11

    An automatic real-time alignment and calibration strategy of the LHCb detector was developed for the Run II. Thanks to the online calibration, tighter event selection criteria can be used in the trigger. Furthermore, the online calibration facilitates the use of hadronic particle identification using the Ring Imaging Cherenkov (RICH) detectors at the trigger level. The motivation for a real-time alignment and calibration of the LHCb detector is discussed from both the operational and physics performance points of view. Specific challenges of this novel configuration are discussed, as well as the working procedures of the framework and its performance.

  13. Novel real-time alignment and calibration of the LHCb detector in Run II

    CERN Document Server

    AUTHOR|(CDS)2086132; Tobin, Mark

    2016-01-01

    An automatic real-time alignment and calibration strategy of the LHCb detector was developed for the Run II. Thanks to the online calibration, tighter event selection criteria can be used in the trigger. Furthermore, the online calibration facilitates the use of hadronic particle identification using the Ring Imaging Cherenkov (RICH) detectors at the trigger level. The motivation for a real-time alignment and calibration of the LHCb detector is discussed from both the operational and physics performance points of view. Specific challenges of this novel configuration are discussed, as well as the working procedures of the framework and its performance.

  14. Multidetector calibration for mass spectrometers

    International Nuclear Information System (INIS)

    Bayne, C.K.; Donohue, D.L.; Fiedler, R.

    1994-06-01

    The International Atomic Energy Agency's Safeguards Analytical Laboratory has performed calibration experiments to measure the different efficiencies among multi-Faraday detectors for a Finnigan-MAT 261 mass spectrometer. Two types of calibration experiments were performed: (1) peak-shift experiments and (2) peak-jump experiments. For peak-shift experiments, the ion intensities were measured for all isotopes of an element in different Faraday detectors. Repeated measurements were made by shifting the isotopes to various Faraday detectors. Two different peak-shifting schemes were used to measure plutonium (UK Pu5/92138) samples. For peak-jump experiments, ion intensities were measured in a reference Faraday detector for a single isotope and compared with those measured in the other Faraday detectors. Repeated measurements were made by switching back-and-forth between the reference Faraday detector and a selected Faraday detector. This switching procedure is repeated for all Faraday detectors. Peak-jump experiments were performed with replicate measurements of 239 Pu, 187 Re, and 238 U. Detector efficiency factors were estimated for both peak-jump and peak-shift experiments using a flexible calibration model to statistically analyze both types of multidetector calibration experiments. Calculated detector efficiency factors were shown to depend on both the material analyzed and the experimental conditions. A single detector efficiency factor is not recommended for each detector that would be used to correct routine sample analyses. An alternative three-run peak-shift sample analysis should be considered. A statistical analysis of the data from this peak-shift experiment can adjust the isotopic ratio estimates for detector differences due to each sample analysis

  15. Calibrating thermal behavior of electronics

    Science.gov (United States)

    Chainer, Timothy J.; Parida, Pritish R.; Schultz, Mark D.

    2016-05-31

    A method includes determining a relationship between indirect thermal data for a processor and a measured temperature associated with the processor, during a calibration process, obtaining the indirect thermal data for the processor during actual operation of the processor, and determining an actual significant temperature associated with the processor during the actual operation using the indirect thermal data for the processor during actual operation of the processor and the relationship.

  16. Calibration of optically trapped nanotools

    Energy Technology Data Exchange (ETDEWEB)

    Carberry, D M; Simpson, S H; Grieve, J A; Hanna, S; Miles, M J [H H Wills Physics Laboratory, University of Bristol, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Wang, Y; Schaefer, H; Steinhart, M [Institute for Chemistry, University of Osnabrueck, Osnabrueck (Germany); Bowman, R; Gibson, G M; Padgett, M J, E-mail: m.j.miles@bristol.ac.uk [SUPA, Department of Physics and Astronomy, University of Glasgow, Science Road, Glasgow G12 8QQ (United Kingdom)

    2010-04-30

    Holographically trapped nanotools can be used in a novel form of force microscopy. By measuring the displacement of the tool in the optical traps, the contact force experienced by the probe can be inferred. In the following paper we experimentally demonstrate the calibration of such a device and show that its behaviour is independent of small changes in the relative position of the optical traps. Furthermore, we explore more general aspects of the thermal motion of the tool.

  17. Study of the performance of diagnostic radiology instruments during calibration

    International Nuclear Information System (INIS)

    Freitas, Rodrigo N. de; Vivolo, Vitor; Potiens, Maria da Penha A.

    2008-01-01

    Full text: The instruments used in diagnostic radiology measurements represent 8 % of the tested instruments by the calibration laboratory of IPEN annually (approximately 1600 in 2007). Considering that the calibration of this kind of instrument is performed biannually it is possible to conclude that almost 300 instruments are being used to measure the air kerma in diagnostic radiology clinics to determine the in beam values (in front of the patient), attenuated measurements (behind the patient) and scattered radiation. This work presents the results of the calibration of the instruments used in mammography, computed tomography, dental and conventional diagnostic radiology dosimetry, performed during the period of 2005 to 2007. Their performances during the calibrations measurements were evaluated. Although at the calibration laboratory there are three available series of radiation quality to this type of calibration (RQR, N and M, according to standards IEC 61267 and ISO 4037-1.), the applications can be assorted (general radiology, computed tomography, mammography, radiation protection and fluoroscopy). Depending on its design and behaviour , one kind of instrument can be used for one or more type of applications. The instruments normally used for diagnostic radiology measurements are ionization chambers with volumes varying from 3 to 1800 cm 3 , and can be cylindrical, spherical or plane parallel plates kind. They usually are sensitive to photon particles, with energies greater than 15 keV and can be used up to 1200 keV. In this work they were tested in X radiation fields from 25 to 150 kV, in specific qualities depending on the utilization of the instrument. The calibration results of 390 instruments received from 2005 to 2007 were analyzed. About 20 instruments were not able to be calibrated due to bad functioning. The calibration coefficients obtained were between 0.88 and 1.24. The uncertainties were always less than ± 3.6% to instruments used in scattered

  18. Calibration of working standard ionization chambers and dose standardization

    International Nuclear Information System (INIS)

    Abd Elmahoud, A. A. B.

    2011-01-01

    Measurements were performed for the calibration of two working standard ionization chambers in the secondary standard dosimetry laboratory of Sudan. 600 cc cylindrical former type and 1800 cc cylindrical radical radiation protection level ionization chambers were calibrated against 1000 cc spherical reference standard ionization chamber. The chamber were calibrated at X-ray narrow spectrum series with beam energies ranged from (33-116 KeV) in addition to 1''3''7''Cs beam with 662 KeV energy. The chambers 0.6 cc and 0.3 cc therapy level ionization were used for dose standardization and beam output calibrations of cobalt-60 radiotherapy machine located at the National Cancer Institute, University of Gazira. Concerning beam output measurements for 6''0''Co radiotherapy machine, dosimetric measurements were performed in accordance with the relevant per IAEA dosimetry protocols TRS-277 and TRS-398. The kinetic energy released per unit mass in air (air kerma) were obtained by multiplying the corrected electrometer reading (nC/min) by the calibration factors (Gy/n C) of the chambers from given in the calibration certificate. The uncertainty of measurements of air kerma were calculated for the all ionization chambers (combined uncertainty) the calibration factors of these ionization chambers then were calculated by comparing the reading of air kerma of secondary standard ionization chambers to than from radical and farmer chambers. The result of calibration working standard ionization chambers showed different calibration factors ranged from 0.99 to 1.52 for different radiation energies and these differences were due to chambers response and specification. The absorbed dose to to water calculated for therapy ionization chamber using two code of practice TRS-277 and TRS-398 as beam output for 6''0''Co radiotherapy machine and it can be used as a reference for future beam output calibration in radiotherapy dosimetry. The measurement of absorbed dose to water showed that the

  19. NSLS-II: Nonlinear Model Calibration for Synchrotrons

    Energy Technology Data Exchange (ETDEWEB)

    Bengtsson, J.

    2010-10-08

    This tech note is essentially a summary of a lecture we delivered to the Acc. Phys. Journal Club Apr, 2010. However, since the estimated accuracy of these methods has been naive and misleading in the field of particle accelerators, i.e., ignores the impact of noise, we will elaborate on this in some detail. A prerequisite for a calibration of the nonlinear Hamiltonian is that the quadratic part has been understood, i.e., that the linear optics for the real accelerator has been calibrated. For synchrotron light source operations, this problem has been solved by the interactive LOCO technique/tool (Linear Optics from Closed Orbits). Before that, in the context of hadron accelerators, it has been done by signal processing of turn-by-turn BPM data. We have outlined how to make a basic calibration of the nonlinear model for synchrotrons. In particular, we have shown how this was done for LEAR, CERN (antiprotons) in the mid-80s. Specifically, our accuracy for frequency estimation was {approx} 1 x 10{sup -5} for 1024 turns (to calibrate the linear optics) and {approx} 1 x 10{sup -4} for 256 turns for tune footprint and betatron spectrum. For a comparison, the estimated tune footprint for stable beam for NSLS-II is {approx}0.1. Since the transverse damping time is {approx}20 msec, i.e., {approx}4,000 turns. There is no fundamental difference for: antiprotons, protons, and electrons in this case. Because the estimated accuracy for these methods in the field of particle accelerators has been naive, i.e., ignoring the impact of noise, we have also derived explicit formula, from first principles, for a quantitative statement. For e.g. N = 256 and 5% noise we obtain {delta}{nu} {approx} 1 x 10{sup -5}. A comparison with the state-of-the-arts in e.g. telecomm and electrical engineering since the 60s is quite revealing. For example, Kalman filter (1960), crucial for the: Ranger, Mariner, and Apollo (including the Lunar Module) missions during the 60s. Or Claude Shannon et al

  20. NSLS-II: Nonlinear Model Calibration for Synchrotrons

    International Nuclear Information System (INIS)

    Bengtsson, J.

    2010-01-01

    This tech note is essentially a summary of a lecture we delivered to the Acc. Phys. Journal Club Apr, 2010. However, since the estimated accuracy of these methods has been naive and misleading in the field of particle accelerators, i.e., ignores the impact of noise, we will elaborate on this in some detail. A prerequisite for a calibration of the nonlinear Hamiltonian is that the quadratic part has been understood, i.e., that the linear optics for the real accelerator has been calibrated. For synchrotron light source operations, this problem has been solved by the interactive LOCO technique/tool (Linear Optics from Closed Orbits). Before that, in the context of hadron accelerators, it has been done by signal processing of turn-by-turn BPM data. We have outlined how to make a basic calibration of the nonlinear model for synchrotrons. In particular, we have shown how this was done for LEAR, CERN (antiprotons) in the mid-80s. Specifically, our accuracy for frequency estimation was ∼ 1 x 10 -5 for 1024 turns (to calibrate the linear optics) and ∼ 1 x 10 -4 for 256 turns for tune footprint and betatron spectrum. For a comparison, the estimated tune footprint for stable beam for NSLS-II is ∼0.1. Since the transverse damping time is ∼20 msec, i.e., ∼4,000 turns. There is no fundamental difference for: antiprotons, protons, and electrons in this case. Because the estimated accuracy for these methods in the field of particle accelerators has been naive, i.e., ignoring the impact of noise, we have also derived explicit formula, from first principles, for a quantitative statement. For e.g. N = 256 and 5% noise we obtain (delta)ν ∼ 1 x 10 -5 . A comparison with the state-of-the-arts in e.g. telecomm and electrical engineering since the 60s is quite revealing. For example, Kalman filter (1960), crucial for the: Ranger, Mariner, and Apollo (including the Lunar Module) missions during the 60s. Or Claude Shannon et al since the 40s for that matter. Conclusion: what

  1. Optimal Reliability-Based Code Calibration

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Kroon, I. B.; Faber, Michael Havbro

    1994-01-01

    Calibration of partial safety factors is considered in general, including classes of structures where no code exists beforehand. The partial safety factors are determined such that the difference between the reliability for the different structures in the class considered and a target reliability...... level is minimized. Code calibration on a decision theoretical basis is also considered and it is shown how target reliability indices can be calibrated. Results from code calibration for rubble mound breakwater designs are shown....

  2. Technical guidelines for personnel dosimetry calibrations

    International Nuclear Information System (INIS)

    Roberson, P.L.; Fox, R.A.; Hadley, R.T.; Holbrook, K.L.; Hooker, C.D.; McDonald, J.C.

    1983-01-01

    A base of technical information has been acquire and used to evaluate the calibration, design, and performance of selected personnel systems in use at Department of Energy (DOE) facilites. A technical document was prepared to guide DOE and DOE contractors in selecting and evaluating personnel dosimetry systems and calibration. A parallel effort was initiated to intercompare the adiological calibrations standards used to calibrate DOE personnel dosimeters

  3. Calibration of ALIBAVA readout system

    Energy Technology Data Exchange (ETDEWEB)

    Trofymov, Artur [DESY, Hamburg (Germany); Collaboration: ATLAS experiment-Collaboration

    2015-07-01

    The High Luminosity Large Hadron Collider (LH-LHC) is the upgrade of the LHC that foreseen to increase the instantaneous luminosity by a factor ten with a total integrated luminosity of 3000 fb{sup -1}. The ATLAS experiment will need to build a new tracker to operate in the new severe LH-LHC conditions (increasing detector granularity to cope with much higher channel occupancy, designing radiation-hard sensors and electronics to cope with radiation damage). Charge collection efficiency (CCE) of silicon strip sensors for the new ATLAS tracker can be done with ALIBAVA analog readout system (analog system gives more information about signal from all strips than digital). In this work the preliminary results of ALIBAVA calibration using two different methods (with ''source data'' and ''calibration data'') are presented. Calibration constant obtained by these methods is necessary for knowing collected charge on the silicon strip sensors and for having the ability to compare it with measurements done at the test beam.

  4. Calibration of RB reactor power

    International Nuclear Information System (INIS)

    Sotic, O.; Markovic, H.; Ninkovic, M.; Strugar, P.; Dimitrijevic, Z.; Takac, S.; Stefanovic, D.; Kocic, A.; Vranic, S.

    1976-09-01

    The first and only calibration of RB reactor power was done in 1962, and the obtained calibration ratio was used irrespective of the lattice pitch and core configuration. Since the RB reactor is being prepared for operation at higher power levels it was indispensable to reexamine the calibration ratio, estimate its dependence on the lattice pitch, critical level of heavy water and thickness of the side reflector. It was necessary to verify the reliability of control and dosimetry instruments, and establish neutron and gamma dose dependence on reactor power. Two series of experiments were done in June 1976. First series was devoted to tests of control and dosimetry instrumentation and measurements of radiation in the RB reactor building dependent on reactor power. Second series covered measurement of thermal and epithermal neuron fluxes in the reactor core and calculation of reactor power. Four different reactor cores were chosen for these experiments. Reactor pitches were 8, 8√2, and 16 cm with 40, 52 and 82 fuel channels containing 2% enriched fuel. Obtained results and analysis of these results are presented in this document with conclusions related to reactor safe operation

  5. Model Calibration in Watershed Hydrology

    Science.gov (United States)

    Yilmaz, Koray K.; Vrugt, Jasper A.; Gupta, Hoshin V.; Sorooshian, Soroosh

    2009-01-01

    Hydrologic models use relatively simple mathematical equations to conceptualize and aggregate the complex, spatially distributed, and highly interrelated water, energy, and vegetation processes in a watershed. A consequence of process aggregation is that the model parameters often do not represent directly measurable entities and must, therefore, be estimated using measurements of the system inputs and outputs. During this process, known as model calibration, the parameters are adjusted so that the behavior of the model approximates, as closely and consistently as possible, the observed response of the hydrologic system over some historical period of time. This Chapter reviews the current state-of-the-art of model calibration in watershed hydrology with special emphasis on our own contributions in the last few decades. We discuss the historical background that has led to current perspectives, and review different approaches for manual and automatic single- and multi-objective parameter estimation. In particular, we highlight the recent developments in the calibration of distributed hydrologic models using parameter dimensionality reduction sampling, parameter regularization and parallel computing.

  6. Calibration of the Site-Scale Saturated Zone Flow Model

    International Nuclear Information System (INIS)

    Zyvoloski, G. A.

    2001-01-01

    The purpose of the flow calibration analysis work is to provide Performance Assessment (PA) with the calibrated site-scale saturated zone (SZ) flow model that will be used to make radionuclide transport calculations. As such, it is one of the most important models developed in the Yucca Mountain project. This model will be a culmination of much of our knowledge of the SZ flow system. The objective of this study is to provide a defensible site-scale SZ flow and transport model that can be used for assessing total system performance. A defensible model would include geologic and hydrologic data that are used to form the hydrogeologic framework model; also, it would include hydrochemical information to infer transport pathways, in-situ permeability measurements, and water level and head measurements. In addition, the model should include information on major model sensitivities. Especially important are those that affect calibration, the direction of transport pathways, and travel times. Finally, if warranted, alternative calibrations representing different conceptual models should be included. To obtain a defensible model, all available data should be used (or at least considered) to obtain a calibrated model. The site-scale SZ model was calibrated using measured and model-generated water levels and hydraulic head data, specific discharge calculations, and flux comparisons along several of the boundaries. Model validity was established by comparing model-generated permeabilities with the permeability data from field and laboratory tests; by comparing fluid pathlines obtained from the SZ flow model with those inferred from hydrochemical data; and by comparing the upward gradient generated with the model with that observed in the field. This analysis is governed by the Office of Civilian Radioactive Waste Management (OCRWM) Analysis and Modeling Report (AMR) Development Plan ''Calibration of the Site-Scale Saturated Zone Flow Model'' (CRWMS M and O 1999a)

  7. 40 CFR 1065.310 - Torque calibration.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Torque calibration. 1065.310 Section... Conditions § 1065.310 Torque calibration. (a) Scope and frequency. Calibrate all torque-measurement systems including dynamometer torque measurement transducers and systems upon initial installation and after major...

  8. Calibration and simulation of Heston model

    Directory of Open Access Journals (Sweden)

    Mrázek Milan

    2017-05-01

    Full Text Available We calibrate Heston stochastic volatility model to real market data using several optimization techniques. We compare both global and local optimizers for different weights showing remarkable differences even for data (DAX options from two consecutive days. We provide a novel calibration procedure that incorporates the usage of approximation formula and outperforms significantly other existing calibration methods.

  9. Nuclear radiation moisture gauge calibration standard

    International Nuclear Information System (INIS)

    1977-01-01

    A hydrophobic standard for calibrating nuclear radiation moisture gauges is described. Each standard has physical characteristics and dimensions effective for representing to a nuclear gauge undergoing calibration, an infinite mass of homogeneous hydrogen content. Calibration standards are discussed which are suitable for use with surface gauges and with depth gauges. (C.F.)

  10. Application of heuristic and machine-learning approach to engine model calibration

    Science.gov (United States)

    Cheng, Jie; Ryu, Kwang R.; Newman, C. E.; Davis, George C.

    1993-03-01

    Automation of engine model calibration procedures is a very challenging task because (1) the calibration process searches for a goal state in a huge, continuous state space, (2) calibration is often a lengthy and frustrating task because of complicated mutual interference among the target parameters, and (3) the calibration problem is heuristic by nature, and often heuristic knowledge for constraining a search cannot be easily acquired from domain experts. A combined heuristic and machine learning approach has, therefore, been adopted to improve the efficiency of model calibration. We developed an intelligent calibration program called ICALIB. It has been used on a daily basis for engine model applications, and has reduced the time required for model calibrations from many hours to a few minutes on average. In this paper, we describe the heuristic control strategies employed in ICALIB such as a hill-climbing search based on a state distance estimation function, incremental problem solution refinement by using a dynamic tolerance window, and calibration target parameter ordering for guiding the search. In addition, we present the application of a machine learning program called GID3* for automatic acquisition of heuristic rules for ordering target parameters.

  11. Balance Problems

    Science.gov (United States)

    ... often, it could be a sign of a balance problem. Balance problems can make you feel unsteady. You may ... related injuries, such as a hip fracture. Some balance problems are due to problems in the inner ...

  12. Agricultural problems

    International Nuclear Information System (INIS)

    Bickerton, George E.

    1997-01-01

    Although there were not reasons to deplore against major activity release from any of the 110 industrial reactors authorized to operate in US, the nuclear incident that occurred at the Three Mile Island Plant in 1979 urged the public conscience toward the necessity of readiness to cope with events of this type. The personnel of the Emergency Planning Office functioning in the frame of US Department of Agriculture has already participated in around 600 intervention drillings on a federal, local or state scale to plan, test or asses radiological emergency plans or to intervene locally. These exercises allowed acquiring a significant experience in elaborating emergency plans, planning the drillings, working out scenarios and evaluation of the potential impact of accidents from the agricultural point of view. We have also taken part in different international drillings among which the most recent are INEX 1 and RADEX 94. We have found on these occasions that the agricultural problems are essential preoccupations in most of the cases no matter if the context is international, national, local or of state level. The paper poses problems specifically related to milk, fruits and vegetables, soils, meat and meat products. Finally the paper discusses issues like drilling planning, alarm and notification, sampling strategy, access authorizations for farmers, removing of contamination wastes. A number of social, political and economical relating problems are also mentioned

  13. Standard practice for torque calibration of testing machines and devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This practice covers procedures and requirements for the calibration of torque for static and quasi-static torque capable testing machines or devices. These may, or may not, have torque indicating systems and include those devices used for the calibration of hand torque tools. Testing machines may be calibrated by one of the three following methods or combination thereof: 1.1.1 Use of standard weights and lever arms. 1.1.2 Use of elastic torque measuring devices. 1.1.3 Use of elastic force measuring devices and lever arms. 1.1.4 Any of the methods require a specific uncertainty of measurement and a traceability derived from national standards of mass and length. 1.2 The procedures of 1.1.1, 1.1.2, and 1.1.3 apply to the calibration of the torque-indicating systems associated with the testing machine, such as a scale, dial, marked or unmarked recorder chart, digital display, etc. In all cases the buyer/owner/user must designate the torque-indicating system(s) to be calibrated and included in the repor...

  14. Calibration and use of filter test facility orifice plates

    Science.gov (United States)

    Fain, D. E.; Selby, T. W.

    1984-07-01

    There are three official DOE filter test facilities. These test facilities are used by the DOE, and others, to test nuclear grade HEPA filters to provide Quality Assurance that the filters meet the required specifications. The filters are tested for both filter efficiency and pressure drop. In the test equipment, standard orifice plates are used to set the specified flow rates for the tests. There has existed a need to calibrate the orifice plates from the three facilities with a common calibration source to assure that the facilities have comparable tests. A project has been undertaken to calibrate these orifice plates. In addition to reporting the results of the calibrations of the orifice plates, the means for using the calibration results will be discussed. A comparison of the orifice discharge coefficients for the orifice plates used at the seven facilities will be given. The pros and cons for the use of mass flow or volume flow rates for testing will be discussed. It is recommended that volume flow rates be used as a more practical and comparable means of testing filters. The rationale for this recommendation will be discussed.

  15. Acoustic calibration apparatus for calibrating plethysmographic acoustic pressure sensors

    Science.gov (United States)

    Zuckerwar, Allan J. (Inventor); Davis, David C. (Inventor)

    1995-01-01

    An apparatus for calibrating an acoustic sensor is described. The apparatus includes a transmission material having an acoustic impedance approximately matching the acoustic impedance of the actual acoustic medium existing when the acoustic sensor is applied in actual in-service conditions. An elastic container holds the transmission material. A first sensor is coupled to the container at a first location on the container and a second sensor coupled to the container at a second location on the container, the second location being different from the first location. A sound producing device is coupled to the container and transmits acoustic signals inside the container.

  16. 40 CFR Appendix Viii to Part 85 - Vehicle and Engine Parameters and Specifications

    Science.gov (United States)

    2010-07-01

    .... Operating pressure(s). h. Injector timing calibrations. V. Injection System. 1. Control parameters and.... Operating pressure(s). h. Injector timing calibration. IV. Ignition System. 1. Control parameters and... calibrations. 2. Component calibrations. c. heavy duty diesel engine parameters and specifications I. Basic...

  17. Heat flux microsensor measurements and calibrations

    Science.gov (United States)

    Terrell, James P.; Hager, Jon M.; Onishi, Shinzo; Diller, Thomas E.

    1992-01-01

    A new thin-film heat flux gage has been fabricated specifically for severe high temperature operation using platinum and platinum-10 percent rhodium for the thermocouple elements. Radiation calibrations of this gage were performed at the AEDC facility over the available heat flux range (approx. 1.0 - 1,000 W/cu cm). The gage output was linear with heat flux with a slight increase in sensitivity with increasing surface temperature. Survivability of gages was demonstrated in quench tests from 500 C into liquid nitrogen. Successful operation of gages to surface temperatures of 750 C has been achieved. No additional cooling of the gages is required because the gages are always at the same temperature as the substrate material. A video of oxyacetylene flame tests with real-time heat flux and temperature output is available.

  18. Broadband standard dipole antenna for antenna calibration

    Science.gov (United States)

    Koike, Kunimasa; Sugiura, Akira; Morikawa, Takao

    1995-06-01

    Antenna calibration of EMI antennas is mostly performed by the standard antenna method at an open-field test site using a specially designed dipole antenna as a reference. In order to develop broadband standard antennas, the antenna factors of shortened dipples are theoretically investigated. First, the effects of the dipole length are analyzed using the induced emf method. Then, baluns and loads are examined to determine their influence on the antenna factors. It is found that transformer-type baluns are very effective for improving the height dependence of the antenna factors. Resistive loads are also useful for flattening the frequency dependence. Based on these studies, a specification is developed for a broadband standard antenna operating in the 30 to 150 MHz frequency range.

  19. [Population problem, comprehension problem].

    Science.gov (United States)

    Tallon, F

    1993-08-01

    Overpopulation of developing countries in general, and Rwanda in particular, is not just their problem but a problem for developed countries as well. Rapid population growth is a key factor in the increase of poverty in sub-Saharan Africa. Population growth outstrips food production. Africa receives more and more foreign food, economic, and family planning aid each year. The Government of Rwanda encourages reduced population growth. Some people criticize it, but this criticism results in mortality and suffering. One must combat this ignorance, but attitudes change slowly. Some of these same people find the government's acceptance of family planning an invasion of their privacy. Others complain that rich countries do not have campaigns to reduce births, so why should Rwanda do so? The rate of schooling does not increase in Africa, even though the number of children in school increases, because of rapid population growth. Education is key to improvements in Africa's socioeconomic growth. Thus, Africa, is underpopulated in terms of potentiality but overpopulated in terms of reality, current conditions, and possibilities of overexploitation. Africa needs to invest in human resources. Families need to save, and to so, they must refrain from having many children. Africa should resist the temptation to waste, as rich countries do, and denounce it. Africa needs to become more independent of these countries, but structural adjustment plans, growing debt, and rapid population growth limit national independence. Food aid is a means for developed countries to dominate developing countries. Modernization through foreign aid has had some positive effects on developing countries (e.g., improved hygiene, mortality reduction), but these also sparked rapid population growth. Rwandan society is no longer traditional, but it is also not yet modern. A change in mentality to fewer births, better quality of life for living infants, better education, and less burden for women must occur

  20. Cross-calibration of interferometric SAR data

    DEFF Research Database (Denmark)

    Dall, Jørgen

    2003-01-01

    Generation of digital elevation models from interferometric synthetic aperture radar (SAR) data is a well established technique. Achieving a high geometric fidelity calls for a calibration accounting for inaccurate navigation data and system parameters as well as system imperfections. Fully...... automated calibration techniques are preferable, especially for operational mapping. The author presents one such technique, called cross-calibration. Though developed for single-pass interferometry, it may be applicable to multi-pass interferometry, too. Cross-calibration requires stability during mapping...... ground control point is often needed. The paper presents the principles and mathematics of the cross-calibration technique and illustrates its successful application to EMISAR data....

  1. Multiple-Objective Stepwise Calibration Using Luca

    Science.gov (United States)

    Hay, Lauren E.; Umemoto, Makiko

    2007-01-01

    This report documents Luca (Let us calibrate), a multiple-objective, stepwise, automated procedure for hydrologic model calibration and the associated graphical user interface (GUI). Luca is a wizard-style user-friendly GUI that provides an easy systematic way of building and executing a calibration procedure. The calibration procedure uses the Shuffled Complex Evolution global search algorithm to calibrate any model compiled with the U.S. Geological Survey's Modular Modeling System. This process assures that intermediate and final states of the model are simulated consistently with measured values.

  2. Pilot study to verify the calibration of electrometers

    International Nuclear Information System (INIS)

    Becker, P.; Meghzifene, A.

    2002-01-01

    Full text: The main detector used for standardization of the quantities used in measurements of ionizing radiation is the ionization chamber. The interaction of the radiation with this detector produces electrical charge, usually, in the range of pC to nC. The instrument used to measure such small charges (or currents) is the electrometer. As part of a good practice, the measured charge (current) must be traceable to a primary or secondary standard. Some calibration laboratories can only provide a system calibration coefficient, i.e. a calibration coefficient for the combination of electrometer plus ionization chamber (Gy/scale division). This practice is acceptable, but it can impose a limitation to the automation of their calibration procedures (using computerized application for the acquisition of current/charge). Not all models have the possibility of a connection to a computer and in the case of those that don't have this capability, automation is not possible without the development of a specific interface. In addition, end-users receive a calibration coefficient, which is only valid for the set ion chamber and electrometer. In case of a broken chamber, the end-user cannot connect another chamber to their electrometer without knowing its calibration coefficient. If the calibration laboratories had the capability of calibrating the chamber separately from the electrometer, for example, using an electrometer calibrated in terms of charge, all the chambers could be calibrated using this electrometer. The laboratory can also benefit from the automation of the measurements. This requires that the laboratory must be able to cross-calibrate the electrometers (associated to the chambers) also in terms of charge (Coulombs). Electrical charge is standardized by the use of a standard air capacitor and a standard voltage source (Q=CV) and the National Laboratory for Metrology of Ionizing Radiation (IRD) in Brazil has also adopted this procedure. Since the Brazilian

  3. The Calibration and error analysis of Shallow water (less than 100m) Multibeam Echo-Sounding System

    Science.gov (United States)

    Lin, M.

    2016-12-01

    Multibeam echo-sounders(MBES) have been developed to gather bathymetric and acoustic data for more efficient and more exact mapping of the oceans. This gain in efficiency does not come without drawbacks. Indeed, the finer the resolution of remote sensing instruments, the harder they are to calibrate. This is the case for multibeam echo-sounding systems (MBES). We are no longer dealing with sounding lines where the bathymetry must be interpolated between them to engender consistent representations of the seafloor. We now need to match together strips (swaths) of totally ensonified seabed. As a consequence, misalignment and time lag problems emerge as artifacts in the bathymetry from adjacent or overlapping swaths, particularly when operating in shallow water. More importantly, one must still verify that bathymetric data meet the accuracy requirements. This paper aims to summarize the system integration involved with MBES and identify the various source of error pertaining to shallow water survey (100m and less). A systematic method for the calibration of shallow water MBES is proposed and presented as a set of field procedures. The procedures aim at detecting, quantifying and correcting systematic instrumental and installation errors. Hence, calibrating for variations of the speed of sound in the water column, which is natural in origin, is not addressed in this document. The data which used in calibration will reference International Hydrographic Organization(IHO) and other related standards to compare. This paper aims to set a model in the specific area which can calibrate the error due to instruments. We will construct a procedure in patch test and figure out all the possibilities may make sounding data with error then calculate the error value to compensate. In general, the problems which have to be solved is the patch test's 4 correction in the Hypack system 1.Roll 2.GPS Latency 3.Pitch 4.Yaw. Cause These 4 correction affect each others, we run each survey line

  4. Genetic calibration of species diversity among North America's freshwater fishes

    OpenAIRE

    April, Julien; Mayden, Richard L.; Hanner, Robert H.; Bernatchez, Louis

    2011-01-01

    Freshwater ecosystems are being heavily exploited and degraded by human activities all over the world, including in North America, where fishes and fisheries are strongly affected. Despite centuries of taxonomic inquiry, problems inherent to species identification continue to hamper the conservation of North American freshwater fishes. Indeed, nearly 10% of species diversity is thought to remain undescribed. To provide an independent calibration of taxonomic uncertainty and to establish a mor...

  5. System for Automated Calibration of Vector Modulators

    Science.gov (United States)

    Lux, James; Boas, Amy; Li, Samuel

    2009-01-01

    Vector modulators are used to impose baseband modulation on RF signals, but non-ideal behavior limits the overall performance. The non-ideal behavior of the vector modulator is compensated using data collected with the use of an automated test system driven by a LabVIEW program that systematically applies thousands of control-signal values to the device under test and collects RF measurement data. The technology innovation automates several steps in the process. First, an automated test system, using computer controlled digital-to-analog converters (DACs) and a computer-controlled vector network analyzer (VNA) systematically can apply different I and Q signals (which represent the complex number by which the RF signal is multiplied) to the vector modulator under test (VMUT), while measuring the RF performance specifically, gain and phase. The automated test system uses the LabVIEW software to control the test equipment, collect the data, and write it to a file. The input to the Lab - VIEW program is either user-input for systematic variation, or is provided in a file containing specific test values that should be fed to the VMUT. The output file contains both the control signals and the measured data. The second step is to post-process the file to determine the correction functions as needed. The result of the entire process is a tabular representation, which allows translation of a desired I/Q value to the required analog control signals to produce a particular RF behavior. In some applications, corrected performance is needed only for a limited range. If the vector modulator is being used as a phase shifter, there is only a need to correct I and Q values that represent points on a circle, not the entire plane. This innovation has been used to calibrate 2-GHz MMIC (monolithic microwave integrated circuit) vector modulators in the High EIRP Cluster Array project (EIRP is high effective isotropic radiated power). These calibrations were then used to create

  6. Specifying Specification.

    Science.gov (United States)

    Paulo, Norbert

    2016-03-01

    This paper tackles the accusation that applied ethics is no serious academic enterprise because it lacks theoretical bracing. It does so in two steps. In the first step I introduce and discuss a highly acclaimed method to guarantee stability in ethical theories: Henry Richardson's specification. The discussion shows how seriously ethicists take the stability of the connection between the foundational parts of their theories and their further development as well as their "application" to particular problems or cases. A detailed scrutiny of specification leads to the second step, where I use insights from legal theory to inform the debate around stability from that point of view. This view reveals some of specification's limitations. I suggest that, once specification is sufficiently specified, it appears astonishingly similar to deduction as used in legal theory. Legal theory also provides valuable insight into the functional range of deduction and its relation to other forms of reasoning. This leads to a richer understanding of stability in normative theories and to a smart division of labor between deduction and other forms of reasoning. The comparison to legal theory thereby provides a framework for how different methods such as specification, deduction, balancing, and analogy relate to one another.

  7. Regression analysis with categorized regression calibrated exposure: some interesting findings

    Directory of Open Access Journals (Sweden)

    Hjartåker Anette

    2006-07-01

    Full Text Available Abstract Background Regression calibration as a method for handling measurement error is becoming increasingly well-known and used in epidemiologic research. However, the standard version of the method is not appropriate for exposure analyzed on a categorical (e.g. quintile scale, an approach commonly used in epidemiologic studies. A tempting solution could then be to use the predicted continuous exposure obtained through the regression calibration method and treat it as an approximation to the true exposure, that is, include the categorized calibrated exposure in the main regression analysis. Methods We use semi-analytical calculations and simulations to evaluate the performance of the proposed approach compared to the naive approach of not correcting for measurement error, in situations where analyses are performed on quintile scale and when incorporating the original scale into the categorical variables, respectively. We also present analyses of real data, containing measures of folate intake and depression, from the Norwegian Women and Cancer study (NOWAC. Results In cases where extra information is available through replicated measurements and not validation data, regression calibration does not maintain important qualities of the true exposure distribution, thus estimates of variance and percentiles can be severely biased. We show that the outlined approach maintains much, in some cases all, of the misclassification found in the observed exposure. For that reason, regression analysis with the corrected variable included on a categorical scale is still biased. In some cases the corrected estimates are analytically equal to those obtained by the naive approach. Regression calibration is however vastly superior to the naive method when applying the medians of each category in the analysis. Conclusion Regression calibration in its most well-known form is not appropriate for measurement error correction when the exposure is analyzed on a

  8. Solid laboratory calibration of a nonimaging spectroradiometer.

    Science.gov (United States)

    Schaepman, M E; Dangel, S

    2000-07-20

    Field-based nonimaging spectroradiometers are often used in vicarious calibration experiments for airborne or spaceborne imaging spectrometers. The calibration uncertainties associated with these ground measurements contribute substantially to the overall modeling error in radiance- or reflectance-based vicarious calibration experiments. Because of limitations in the radiometric stability of compact field spectroradiometers, vicarious calibration experiments are based primarily on reflectance measurements rather than on radiance measurements. To characterize the overall uncertainty of radiance-based approaches and assess the sources of uncertainty, we carried out a full laboratory calibration. This laboratory calibration of a nonimaging spectroradiometer is based on a measurement plan targeted at achieving a calibration. The individual calibration steps include characterization of the signal-to-noise ratio, the noise equivalent signal, the dark current, the wavelength calibration, the spectral sampling interval, the nonlinearity, directional and positional effects, the spectral scattering, the field of view, the polarization, the size-of-source effects, and the temperature dependence of a particular instrument. The traceability of the radiance calibration is established to a secondary National Institute of Standards and Technology calibration standard by use of a 95% confidence interval and results in an uncertainty of less than ?7.1% for all spectroradiometer bands.

  9. Muon Energy Calibration of the MINOS Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Miyagawa, Paul S. [Somerville College, Oxford (United Kingdom)

    2004-01-01

    MINOS is a long-baseline neutrino oscillation experiment designed to search for conclusive evidence of neutrino oscillations and to measure the oscillation parameters precisely. MINOS comprises two iron tracking calorimeters located at Fermilab and Soudan. The Calibration Detector at CERN is a third MINOS detector used as part of the detector response calibration programme. A correct energy calibration between these detectors is crucial for the accurate measurement of oscillation parameters. This thesis presents a calibration developed to produce a uniform response within a detector using cosmic muons. Reconstruction of tracks in cosmic ray data is discussed. This data is utilized to calculate calibration constants for each readout channel of the Calibration Detector. These constants have an average statistical error of 1.8%. The consistency of the constants is demonstrated both within a single run and between runs separated by a few days. Results are presented from applying the calibration to test beam particles measured by the Calibration Detector. The responses are calibrated to within 1.8% systematic error. The potential impact of the calibration on the measurement of oscillation parameters by MINOS is also investigated. Applying the calibration reduces the errors in the measured parameters by ~ 10%, which is equivalent to increasing the amount of data by 20%.

  10. Calibration-on-the-spot”: How to calibrate an EMCCD camera from its images

    DEFF Research Database (Denmark)

    Mortensen, Kim; Flyvbjerg, Henrik

    2016-01-01

    In order to count photons with a camera, the camera must be calibrated. Photon counting is necessary, e.g., to determine the precision of localization-based super-resolution microscopy. Here we present a protocol that calibrates an EMCCD camera from information contained in isolated, diffraction-......-limited spots in any image taken by the camera, thus making dedicated calibration procedures redundant by enabling calibration post festum, from images filed without calibration information....

  11. Media Ethics: Some Specific Problems. ERIC Digest.

    Science.gov (United States)

    Gottlieb, Stephen S.

    This digest identifies some of the ethical issues which appeared in the mass media in the 1980s and discusses the implications which these issues have for the law and for those who already work in or study the mass media, as well as for those college students contemplating a career in journalism or broadcasting. (NKA)

  12. General anesthesia for horses with specific problems

    International Nuclear Information System (INIS)

    Hodgson, D.S.; Dunlop, C.I.

    1990-01-01

    We have discussed anesthetic techniques, special considerations, and expected complications involved in anesthetizing horses for abdominal, orthopedic, and head and neck surgery, and myelography and have described expected physiologic dysfunction that may require changes in anesthetic technique or supportive measures. The objective is high-quality patient care and reduction in anesthesia-related morbidity and death

  13. SPECIFIC PERTUSSIS PREVENTION: PROBLEMS AND PERSPECTIVES

    Directory of Open Access Journals (Sweden)

    S.M. Kharit

    2007-01-01

    Full Text Available The lecture shows the modern state of the pertussis issue among the children. Based on the analysis of the presented data, the authors conclude that vaccination with the full cellular vaccine is rather safe; moreover, it protects the infants from the severe forms of the disease and lethal outcomes. However, the fact that there are children with constant contraindications to immunization with the full cellular vaccine, the change of the circulating B. pertussis serotypes, morbidity of the older children due to the loss of the postcvaccinal immunity define the necessity to introduce revaccination, as well as they are indications to the wider implementation of the non-cellular pertussis vaccine.Key words: pertussis, children, vaccination, full cellular pertussis vaccine, non-cellular pertussis vaccine.

  14. Calibration of hydrological model with programme PEST

    Science.gov (United States)

    Brilly, Mitja; Vidmar, Andrej; Kryžanowski, Andrej; Bezak, Nejc; Šraj, Mojca

    2016-04-01

    PEST is tool based on minimization of an objective function related to the root mean square error between the model output and the measurement. We use "singular value decomposition", section of the PEST control file, and Tikhonov regularization method for successfully estimation of model parameters. The PEST sometimes failed if inverse problems were ill-posed, but (SVD) ensures that PEST maintains numerical stability. The choice of the initial guess for the initial parameter values is an important issue in the PEST and need expert knowledge. The flexible nature of the PEST software and its ability to be applied to whole catchments at once give results of calibration performed extremely well across high number of sub catchments. Use of parallel computing version of PEST called BeoPEST was successfully useful to speed up calibration process. BeoPEST employs smart slaves and point-to-point communications to transfer data between the master and slaves computers. The HBV-light model is a simple multi-tank-type model for simulating precipitation-runoff. It is conceptual balance model of catchment hydrology which simulates discharge using rainfall, temperature and estimates of potential evaporation. Version of HBV-light-CLI allows the user to run HBV-light from the command line. Input and results files are in XML form. This allows to easily connecting it with other applications such as pre and post-processing utilities and PEST itself. The procedure was applied on hydrological model of Savinja catchment (1852 km2) and consists of twenty one sub-catchments. Data are temporary processed on hourly basis.

  15. Traceable calibration of hospital 192Ir HDR sources

    International Nuclear Information System (INIS)

    Govinda Rajan, K.N.; Bhatt, B.C.; Pendse, A.M.; Kannan, V.

    2002-01-01

    Presently, no primary standard exists for the standardization of remote afterloading 192 Ir HDR sources. These sources are, therefore, being standardized by a few Secondary Standard Dosimetry Laboratories (SSDLs), in terms of Air Kerma Strength (AKS) or Reference Air Kerma Rate (RAKR) using a 0.6 cc Farmer type chamber, set up as an Interim Standard. These SSDLs offer calibration to well type of ionization chambers that are normally used by the hospitals for calibrating the 192 lr HDR source. Presently, in many countries, including India, well chambers are not commercially available. Nor do these countries offer any calibration service for 192 lr HDR source. With the result users make use of well chambers imported from different countries with their calibration traceable to the country of origin. Since no intercomparisons between these countries have been reported, the measurement consistency between hospitals becomes questionable. The problem is compounded by the fact that these chambers are used for several years without re-calibration since no calibration service is locally available. For instance, in India, the chambers have been in use in hospitals, since 1994, without a second calibration. Not all hospitals use the well chamber for the calibration of the 192 lr HDR source. Many hospitals make use of 0.6 cc chambers, in air, at short source to chamber distances, for measuring the AKS of the source. The latter method is prone to much larger inaccuracy due to the use of very short source to chamber distances without proper calibration jigs, use of 60 Co calibration factor for 192 Ir HDR source calibrations, neglecting correction factors for room scatter, fluence non-uniformity, use of arbitrary buildup factors for the buildup cap of the chamber etc. A comparison of the procedures used at hospitals revealed that various arbitrary methods are in use at hospitals. An indigenously developed well chamber was calibrated against a Reference Standard traceable to the

  16. Laboratory panel and radiometer calibration

    CSIR Research Space (South Africa)

    Deadman, AJ

    2011-07-01

    Full Text Available stream_source_info Griffith1_2011.pdf.txt stream_content_type text/plain stream_size 16659 Content-Encoding ISO-8859-1 stream_name Griffith1_2011.pdf.txt Content-Type text/plain; charset=ISO-8859-1 LABORATORY PANEL... of Land surface imaging through a ground reference standard test site?, on http://qa4eo.org/documentation.html, 2009. [2] K. J. Thome, D. L. Helder, D. Aaron, and J. D. Dewald, ?Landsat-5 TM and Landsat-7 ETM+ Absolute Radiometric Calibration Using...

  17. A Cryogenic Infrared Calibration Target

    Science.gov (United States)

    Wollack, E. J.; Kinzer, R. E., Jr.; Rinehart, S. A.

    2014-01-01

    A compact cryogenic calibration target is presented that has a peak diffuse reflectance, R target. The resulting target assembly is lightweight, has a low-geometric profile, and has survived repeated thermal cycling from room temperature to approx.4 K. Basic design considerations, governing equations, and test data for realizing the structure described are provided. The optical properties of selected absorptive materials-Acktar Fractal Black, Aeroglaze Z306, and Stycast 2850 FT epoxy loaded with stainless steel powder-are characterized and presented

  18. X-ray film calibration

    International Nuclear Information System (INIS)

    Stone, G.F.; Dittmore, C.H.; Henke, B.L.

    1986-01-01

    This paper discusses the use of silver halide x-ray films for imaging and spectroscopy which is limited by the range of intensities that can be recorded and densitometered. Using the manufacturers processing techniques can result in 10 2-3 range in intensity recorded over 0-5 density range. By modifying the chemistry and processing times, ranges of 10 5-6 can be recorded in the same density range. The authors report on x-ray film calibration work and dynamic range improvements. Changes to the processing chemistry and the resulting changes in dynamic range and x-ray sensitivity are discussed

  19. Calibration of TOB+ Thermometer's Cards

    CERN Document Server

    Banitt, Daniel

    2014-01-01

    Motivation - Under the new upgrade of the CMS detector the working temperature of the trackers had been reduced to -27 Celsius degrees. Though the thermal sensors themselves (Murata and Fenwal thermistors) are effective at these temperatures, the max1542 PLC (programmable logic controller) cards, interpreting the resistance of the thermal sensors into DC counts usable by the DCS (detector control system), are not designed for these temperatures in which the counts exceed their saturation and therefor had to be replaced. In my project I was in charge of handling the emplacement and calibration of the new PLC cards to the TOB (tracker outer barrel) control system.

  20. Calibration procedures for in vivo sodium iodide spectrometry of plutonium and americium in the human lung

    International Nuclear Information System (INIS)

    Umbarger, C.J.; Jett, J.H.

    1976-01-01

    This paper describes the calibration techniques and associated error analysis for the in vivo measurement by NaI spectrometry of heavy elements in the lung, specifically plutonium and americium. A very brief description of the instrumentation system is included