WorldWideScience

Sample records for spacelab instrument pointing

  1. Spacelab Science Results Study

    Science.gov (United States)

    Naumann, R. J.; Lundquist, C. A.; Tandberg-Hanssen, E.; Horwitz, J. L.; Germany, G. A.; Cruise, J. F.; Lewis, M. L.; Murphy, K. L.

    2009-01-01

    Beginning with OSTA-1 in November 1981 and ending with Neurolab in March 1998, a total of 36 Shuttle missions carried various Spacelab components such as the Spacelab module, pallet, instrument pointing system, or mission peculiar experiment support structure. The experiments carried out during these flights included astrophysics, solar physics, plasma physics, atmospheric science, Earth observations, and a wide range of microgravity experiments in life sciences, biotechnology, materials science, and fluid physics which includes combustion and critical point phenomena. In all, some 764 experiments were conducted by investigators from the U.S., Europe, and Japan. The purpose of this Spacelab Science Results Study is to document the contributions made in each of the major research areas by giving a brief synopsis of the more significant experiments and an extensive list of the publications that were produced. We have also endeavored to show how these results impacted the existing body of knowledge, where they have spawned new fields, and if appropriate, where the knowledge they produced has been applied.

  2. Critical Point Facility (CPE) Group in the Spacelab Payload Operations Control Center (SL POCC)

    Science.gov (United States)

    1992-01-01

    The primary payload for Space Shuttle Mission STS-42, launched January 22, 1992, was the International Microgravity Laboratory-1 (IML-1), a pressurized manned Spacelab module. The goal of IML-1 was to explore in depth the complex effects of weightlessness of living organisms and materials processing. Around-the-clock research was performed on the human nervous system's adaptation to low gravity and effects of microgravity on other life forms such as shrimp eggs, lentil seedlings, fruit fly eggs, and bacteria. Materials processing experiments were also conducted, including crystal growth from a variety of substances such as enzymes, mercury iodide, and a virus. The Huntsville Operations Support Center (HOSC) Spacelab Payload Operations Control Center (SL POCC) at the Marshall Space Flight Center (MSFC) was the air/ground communication channel used between the astronauts and ground control teams during the Spacelab missions. Featured is the Critical Point Facility (CPE) group in the SL POCC during STS-42, IML-1 mission.

  3. Spacelab shaping space operations planning

    Science.gov (United States)

    Steven, F. R.; Reinhold, C.

    1976-01-01

    An up-to-date picture is presented of the organizational structure, the key management personnel, and management relationships of the Spacelab program. Attention is also given to Spacelab's development status and plans for its operations. A number of charts are provided to illustrate the organizational relations. It is pointed out that the parties involved in Spacelab activities must yet resolve questions about ownership of transportation-system elements, payloads, ground support facilities, and data obtained from space missions.

  4. Spacelab Users Guide: A Short Introduction to Spacelab and Its Use

    Science.gov (United States)

    1976-01-01

    Spacelab is an orbital facility that provides a pressurized, 'shirt-sleeve' laboratory (the module) and an unpressurized platform (the pallet), together with certain standard services. It is a reusable system, which is transported to and from orbit in the cargo bay of the space shuttle orbiter and remains there throughout the flight. Spacelab extends the shuttle capability, and the Orbiter/Spacelab combination can be regarded as a short-stay space station which can remain in orbit for up to 30 days (the nominal mission duration is 7 days). In orbit, the experiments carried by Spacelab are operated by a team of up to four payload specialists who normally work in the laboratory, but spend their off-duty time in the orbiter cabin. The purpose of Spacelab is to provide a ready access to space for a broad spectrum of experimenters in many fields and from many nations. Low-cost techniques are envisaged for experiment development, integration and operation. The aim of this document is to provide a brief summary of Spacelab design characteristics and its use potential for experimenters wishing to take advantage of the unique opportunities offered for space experimentation.

  5. Spacelab Life Sciences-1

    Science.gov (United States)

    Dalton, Bonnie P.; Jahns, Gary; Meylor, John; Hawes, Nikki; Fast, Tom N.; Zarow, Greg

    1995-01-01

    This report provides an historical overview of the Spacelab Life Sciences-1 (SLS-1) mission along with the resultant biomaintenance data and investigators' findings. Only the nonhuman elements, developed by Ames Research Center (ARC) researchers, are addressed herein. The STS-40 flight of SLS-1, in June 1991, was the first spacelab flown after 'return to orbit', it was also the first spacelab mission specifically designated as a Life Sciences Spacelab. The experiments performed provided baseline data for both hardware and rodents used in succeeding missions.

  6. Space platforms - A cost effective evolution of Spacelab operation

    Science.gov (United States)

    Stofan, A. J.

    1981-01-01

    The capabilities added to the Shuttle/Spacelab configuration by the addition of the Power Extension Package (PEP), the Power System (PS), and the Science and Applications Space Platforms (SASP) are reviewed with an emphasis on SASP. SASP are intended for placement in orbit by the Shuttle to test new instruments and systems, for clustering of instrumentation, and for servicing, refurbishment, repair, or augmentation by the Shuttle. The PEP permits extended stays in orbit (30 days), and the PS is an orbital solar array and energy storage system acting as a free flying spacecraft. The Shuttle can deliver payloads to the PS or attach to it for extension of the Spacelab operations. Applications of SASP for long term space-based biological experiments are outlined, and the fact that SASP do not increase the required Shuttle in-orbit time is stressed.

  7. Image motion compensation on the Spacelab 2 Solar Optical Universal Polarimeter /SL2 SOUP/

    Science.gov (United States)

    Tarbell, T. D.; Duncan, D. W.; Finch, M. L.; Spence, G.

    1981-01-01

    The SOUP experiment on Spacelab 2 includes a 30 cm visible light telescope and focal plane package mounted on the Instrument Pointing System (IPS). Scientific goals of the experiment dictate pointing stability requirements of less than 0.05 arcsecond jitter over periods of 5-20 seconds. Quantitative derivations of these requirements from two different aspects are presented: (1) avoidance of motion blurring of diffraction-limited images; (2) precise coalignment of consecutive frames to allow measurement of small image differences. To achieve this stability, a fine guider system capable of removing residual jitter of the IPS and image motions generated on the IPS cruciform instrument support structure has been constructed. This system uses solar limb detectors in the prime focal plane to derive an error signal. Image motion due to pointing errors is compensated by the agile secondary mirror mounted on piezoelectric transducers, controlled by a closed-loop servo system.

  8. Spacelab-3 (STS-51B) Onboard Photograph

    Science.gov (United States)

    1985-01-01

    The primary purpose of the Spacelab-3 mission was to conduct materials science experiments in a stable low-gravity environment. In addition, the crew performed research in life sciences, fluid mechanics, atmospheric science, and astronomy. Spacelab-3 was equipped with several new minilabs, special facilities that would be used repeatedly on future flights. Two elaborate crystal growth furnaces, a life support and housing facility for small animals, and two types of apparatus for the study of fluids were evaluated on their inaugural flight. In this photograph, astronaut Don Lind observes the mercuric iodide growth experiment through a microscope at the vapor crystal growth furnace. The goals of this investigation were to grow near-perfect single crystals of mercuric iodide and to gain improved understanding of crystal growth by a vapor process. Mercuric iodide crystals have practical use as sensitive x-ray and gamma-ray detectors, and in portable detector devices for nuclear power plant monitoring, natural resource prospecting, biomedical applications in diagnosis and therapy, and in astronomical instruments. Managed by the Marshall Space Flight Center, Spacelab-3 (STS-51B) was launched aboard the Space Shuttle Orbiter Challenger on April 29, 1985.

  9. The Spacelab IPS Star Simulator

    Science.gov (United States)

    Wessling, Francis C., III

    The cost of doing business in space is very high. If errors occur while in orbit the costs grow and desired scientific data may be corrupted or even lost. The Spacelab Instrument Pointing System (IPS) Star Simulator is a unique test bed that allows star trackers to interface with simulated stars in a laboratory before going into orbit. This hardware-in-the loop testing of equipment on earth increases the probability of success while in space. The IPS Star Simulator provides three fields of view 2.55 x 2.55 degrees each for input into star trackers. The fields of view are produced on three separate monitors. Each monitor has 4096 x 4096 addressable points and can display 50 stars (pixels) maximum at a given time. The pixel refresh rate is 1000 Hz. The spectral output is approximately 550 nm. The available relative visual magnitude range is 2 to 8 visual magnitudes. The star size is less than 100 arc seconds. The minimum star movement is less than 5 arc seconds and the relative position accuracy is approximately 40 arc seconds. The purpose of this paper is to describe the LPS Star Simulator design and to provide an operational scenario so others may gain from the approach and possible use of the system.

  10. European X-ray spectroscopy and polarimetry payload for Spacelab

    Energy Technology Data Exchange (ETDEWEB)

    Andresen, R D; Whitcomb, G [European Space Research and Technology Centre, Noordwijk (Netherlands); Brinkman, A C [Space Research Laboratory, Utrecht, The Netherlands; Beuermann, K [Max-Planck-Institut fuer Physik und Astrophysik, Garching/Muenchen (Germany, F.R.). Inst. fuer Extraterrestrische Physik; Culhane, J L [University Coll., London (UK). Mullard Space Science Lab.; Griffiths, R [Leicester Univ. (UK); Manno, V [ESA Headquarters, Paris, France; Rocchia, R [CEA Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1976-08-01

    A group of instruments for X-ray spectroscopy and polarimetry studies of a number of cosmic X-ray sources is being designed for possible use on Spacelab. Large area Bragg spectrometers and polarimeters for photon energies above 2 keV are described. For the energy range below 2 keV, both dispersive and non-dispersive spectrometers are employed at the common focus of a nested array of paraboloids. Following a brief outline of the scientific background to the mission, the properties of the individual instruments are discussed.

  11. Spacelab 3 mission

    Science.gov (United States)

    Dalton, Bonnie P.

    1990-01-01

    Spacelab-3 (SL-3) was the first microgravity mission of extended duration involving crew interaction with animal experiments. This interaction involved sharing the Spacelab environmental system, changing animal food, and changing animal waste trays by the crew. Extensive microbial testing was conducted on the animal specimens and crew and on their ground and flight facilities during all phases of the mission to determine the potential for cross contamination. Macroparticulate sampling was attempted but was unsuccessful due to the unforseen particulate contamination occurring during the flight. Particulate debris of varying size (250 micron to several inches) and composition was recovered post flight from the Spacelab floor, end cones, overhead areas, avionics fan filter, cabin fan filters, tunnel adaptor, and from the crew module. These data are discussed along with solutions, which were implemented, for particulate and microbial containment for future flight facilities.

  12. Spacelab Life Sciences Research Panel

    Science.gov (United States)

    Sulzman, Frank; Young, Laurence R.; Seddon, Rhea; Ross, Muriel; Baldwin, Kenneth; Frey, Mary Anne; Hughes, Rod

    2000-01-01

    This document describes some of the life sciences research that was conducted on Spacelab missions. Dr. Larry Young, Director of the National Space Biomedical Research Institute, provides an overview of the Life Sciences Spacelabs.

  13. A coded mask telescope for the Spacelab 2 mission

    International Nuclear Information System (INIS)

    Willmore, A.P.; Skinner, G.K.; Eyles, C.J.; Ramsey, B.

    1984-01-01

    A dual coded mask telescope for the Spacelab 2 mission is now in the final stages of preparation at Birmingham University. It is due for launch in late 1984/early 1985 and will be by far the largest and most sophisticated such instrument to be flown in this time-frame. The design and capabilities of the telescope will be described. (orig.)

  14. Interim Report of the Astronomy Spacelab Payloads Study. Volume 2; Ultraviolet and Optical Astronomy

    Science.gov (United States)

    1975-01-01

    The Space Shuttle will comprise NASA's primary transportation system into near-earth orbit during the 1980s. The Shuttle will provide the astronomical community with a major new capability to send a wide variety of instrumentation into orbit, to utilize it there under manned or automatic control for periods from seven to thirty days, and to return it to the ground. To this end the European Space Research Organization (ESRO) is developing Spacelab, an array of interchangeable components -pressurized manned modules, unpressurized pallets and related support systems - to be mounted in the Shuttle payload bay. Spacelab will offer important opportunities to carry out astronomical research with instruments optimized for specific objectives. With a high flight frequency and with the ability to modify or interchange telescopes and instruments between flights, one will not need to make rigid long-term commitments to specific and compromised telescope/instrument/ detector combinations as is the case for automated satellites. Observational techniques demanding the physical return of data and equipment - in particular the use of photographic film, instruments requiring tight calibration controls, cryogens, high-risk detectors and degradeable optical coatings -will open research areas not readily addressed by automated satellites. Although Shuttle flight duration will be limited to periods from seven to thirty days, substantial data can be obtained with a single instrument on short missions, if targets are carefully selected and prioritized, and a large number of instruments can be accommodated on a single flight. Important astronomical data are regularly obtained on sounding rocket flights of five minutes duration. Spacelab will provide far longer observing periods for large and small telescopes, with resources greatly exceeding those of sounding rockets, while retaining much of the sounding rocket philosophy in terms of instrument flexibility, simplicity, reliability

  15. The first Spacelab payload - A joint NASA/ESA venture

    Science.gov (United States)

    Kennedy, R.; Pace, R.; Collet, J.; Sanfourche, J. P.

    1977-01-01

    Planning for the 1980 qualification flight of Spacelab, which will involve a long module and one pallet, is discussed. The mission will employ two payload specialists, one sponsored by NASA and the other by ESA. Management of the Spacelab mission functions, including definition and execution of the on-board experiments, development of the experimental hardware and training of the payload specialists, is considered; studies proposed in the areas of atmospheric physics, space plasma physics, solar physics, earth observations, astronomy, astrophysics, life sciences and material sciences are reviewed. Analyses of the Spacelab environment and the Spacelab-to-orbiter and Spacelab-to-experiment interactions are also planned.

  16. Spacelab ready for transport to Washington, DC

    Science.gov (United States)

    1998-01-01

    Spacelab is wrapped and ready for transport to the National Air and Space Museum in Washington, DC. Spacelab was designed by the European Space Agency (ESA) for the Space Shuttle program and first flew on STS-9 in November 1983. Its final flight was the STS-90 Neurolab mission in April 1998. A sister module will travel home and be placed on display in Europe. The Spacelab concept of modular experiment racks in a pressurized shirt-sleeve environment made it highly user-friendly and accessible. Numerous experiments conceived by hundreds of scientists on the ground were conducted by flight crews in orbit. Spacelab modules served as on-orbit homes for everything from squirrel monkeys to plant seeds. They supported astronomical as well as Earth observations, for servicing the Hubble Space Telescope and for research preparatory to the International Space Station. One of the greatest benefits afforded by the Spacelab missions was the opportunity to fly a mission more than once, with the second or third flight building on the experiences and data gathered from its predecessors.

  17. Approach to Spacelab Payload mission management

    Science.gov (United States)

    Craft, H. G.; Lester, R. C.

    1978-01-01

    The nucleus of the approach to Spacelab Payload mission management is the establishment of a single point of authority for the entire payload on a given mission. This single point mission manager will serve as a 'broker' between the individual experiments and the STS, negotiating agreements by two-part interaction. The payload mission manager, along with a small support team, will represent the users in negotiating use of STS accommodations. He will provide the support needed by each individual experimenter to meet the scientific, technological, and applications objectives of the mission with minimum cost and maximum efficiency. The investigator will assume complete responsibility for his experiment hardware definition and development and will take an active role in the integration and operation of his experiment.

  18. A review of Spacelab mission management approach

    Science.gov (United States)

    Craft, H. G., Jr.

    1979-01-01

    The Spacelab development program is a joint undertaking of the NASA and ESA. The paper addresses the initial concept of Spacelab payload mission management, the lessons learned, and modifications made as a result of the actual implementation of Spacelab Mission 1. The discussion covers mission management responsibilities, program control, science management, payload definition and interfaces, integrated payload mission planning, integration requirements, payload specialist training, payload and launch site integration, payload flight/mission operations, and postmission activities. After 3.5 years the outlined overall mission manager approach has proven to be most successful. The approach does allow the mission manager to maintain the lowest overall mission cost.

  19. Statistical properties of solar granulation from the SOUP instrument on Spacelab 2

    International Nuclear Information System (INIS)

    Topka, K.; Title, A.; Tarbell, T.; Ferguson, S.; Shine, R.

    1988-01-01

    The Solar Optical Universal Polarimeter (SOUP) on Spacelab 2 collected movies of solar granulation completely free from atmospheric blurring, and are not degraded by pointint jitter (the pointing stability was 0.003 sec root mean square). The movies illustrate that the solar five minute oscillation has a major role in the appearance of solar granulation and that exploding granules are a common feature of the granule evolution. Using 3-D Fourier filtering techniques the oscillations were removed and it was demonstrated that the autocorrelation lifetime of granulation is a factor of two greater in magnetic field regions than in field-free quiet sun. Horizontal velocities were measured and flow patterns were observed on the scale of meso- and super granulation. In quiet regions the mean flow velocity is 370 m/s while in the magnetic regions it is about 125 m/s. It was also found that the root mean square (RMS) fluctuating horizonal velocity field is substantially greater in quiet sun than in strong magnetic field regions. By superimposing the location of exploding granules on the average flow maps it was found that they appear almost exclusively in the center of mesogranulation size flow cells. Because of the nonuniformity of the distribution of exploding granules, the evolution of the granulation pattern in mesogranule cell centers and boundaries differs fundamentally. It is clear from this study there is neither a typical granule nor a typical granule evolution

  20. Statistical properties of solar granulation from the SOUP instrument on Spacelab 2

    Science.gov (United States)

    Topka, K.; Title, A.; Tarbell, T.; Ferguson, S.; Shine, R.

    1988-11-01

    The Solar Optical Universal Polarimeter (SOUP) on Spacelab 2 collected movies of solar granulation completely free from atmospheric blurring, and are not degraded by pointint jitter (the pointing stability was 0.003 sec root mean square). The movies illustrate that the solar five minute oscillation has a major role in the appearance of solar granulation and that exploding granules are a common feature of the granule evolution. Using 3-D Fourier filtering techniques the oscillations were removed and it was demonstrated that the autocorrelation lifetime of granulation is a factor of two greater in magnetic field regions than in field-free quiet sun. Horizontal velocities were measured and flow patterns were observed on the scale of meso- and super granulation. In quiet regions the mean flow velocity is 370 m/s while in the magnetic regions it is about 125 m/s. It was also found that the root mean square (RMS) fluctuating horizonal velocity field is substantially greater in quiet sun than in strong magnetic field regions. By superimposing the location of exploding granules on the average flow maps it was found that they appear almost exclusively in the center of mesogranulation size flow cells. Because of the nonuniformity of the distribution of exploding granules, the evolution of the granulation pattern in mesogranule cell centers and boundaries differs fundamentally. It is clear from this study there is neither a typical granule nor a typical granule evolution.

  1. Spacelab operations planning. [ground handling, launch, flight and experiments

    Science.gov (United States)

    Lee, T. J.

    1976-01-01

    The paper reviews NASA planning in the fields of ground, launch and flight operations and experiment integration to effectively operate Spacelab. Payload mission planning is discussed taking consideration of orbital analysis and the mission of a multiuser payload which may be either single or multidiscipline. Payload analytical integration - as active process of analyses to ensure that the experiment payload is compatible to the mission objectives and profile ground and flight operations and that the resource demands upon Spacelab can be satisfied - is considered. Software integration is touched upon and the major integration levels in ground operational processing of Spacelab and its experimental payloads are examined. Flight operations, encompassing the operation of the Space Transportation System and the payload, are discussed as are the initial Spacelab missions. Charts and diagrams are presented illustrating the various planning areas.

  2. Spacelab experiment computer study. Volume 1: Executive summary (presentation)

    Science.gov (United States)

    Lewis, J. L.; Hodges, B. C.; Christy, J. O.

    1976-01-01

    A quantitative cost for various Spacelab flight hardware configurations is provided along with varied software development options. A cost analysis of Spacelab computer hardware and software is presented. The cost study is discussed based on utilization of a central experiment computer with optional auxillary equipment. Groundrules and assumptions used in deriving the costing methods for all options in the Spacelab experiment study are presented. The groundrules and assumptions, are analysed and the options along with their cost considerations, are discussed. It is concluded that Spacelab program cost for software development and maintenance is independent of experimental hardware and software options, that distributed standard computer concept simplifies software integration without a significant increase in cost, and that decisions on flight computer hardware configurations should not be made until payload selection for a given mission and a detailed analysis of the mission requirements are completed.

  3. Correlation lifetimes of quiet and magnetic granulation from the SOUP instrument on Spacelab 2

    Science.gov (United States)

    Title, A.; Tarbell, T.; Topka, K.; Acton, L.; Duncan, D.; Ferguson, S.; Finch, M.; Frank, Z.; Kelly, G.; Lindgren, R.; Morrill, M.; Pope, T.; Reeves, R.; Rehse, R.; Shine, R.; Simon, G.; Harvey, J.; Leibacher, J.; Livingston, W.; November, L.; Zirker, J.

    The time sequences of diffraction limited granulation images obtained by the Solar Optical Universal Polarimeter on Spacelab 2 are presented. The uncorrection autocorrelation limetime in magnetic regions is dominated by the 5-min oscillation. The removal of this oscillation causes the autocorrelation lifetime to increase by more than a factor of 2. The results suggest that a significant fraction of granule lifetimes are terminated by nearby explosions. Horizontal displacements and transverse velocities in the intensity field are measured. Lower limits to the lifetime in the quiet and magnetic sun are set at 440 s and 950 s, respectively.

  4. STS-40 Spacelab Life Science 1 (SLS-1) module in OV-102's payload bay (PLB)

    Science.gov (United States)

    1991-01-01

    STS-40 Spacelab Life Science 1 (SLS-1) module is documented in the payload bay (PLB) of Columbia, Orbiter Vehicle (OV) 102. Included in the view are: the spacelab (SL) transfer tunnel joggle section and support struts; SLS-1 module forward end cone with the European Space Agency (ESA) SL insignia, SLS-1 payload insignia, and the upper feed through plate (center); the orbiter maneuvering system (OMS) pods; and the vertical stabilizer with the Detailed Test Objective (DTO) 901 Shuttle Infrared Leeside Temperature Sensing (SILTS) at the top 24 inches. The vertical stabilizer points to the Earth's limb and the cloud-covered surface of the Earth below.

  5. Plasma diagnostics package. Volume 2: Spacelab 2 section. Part B: Thesis projects

    Science.gov (United States)

    Pickett, Jolene S. (Compiler); Frank, L. A. (Compiler); Kurth, W. S. (Compiler)

    1988-01-01

    This volume (2), which consists of two parts (A and B), of the Plasma Diagnostics Package (PDP) Final Science Report contains a summary of all of the data reduction and scientific analyses which were performed using PDP data obtained on STS-51F as a part of the Spacelab 2 (SL-2) payload. This work was performed during the period of launch, July 29, 1985, through June 30, 1988. During this period the primary data reduction effort consisted of processing summary plots of the data received by 12 of the 14 instruments located on the PDP and submitting these data to the National Space Science Data Center (NSSDC). Three Master's and three Ph.D. theses were written using PDP instrumentation data. These theses are listed in Volume 2, Part B.

  6. More Life-Science Experiments For Spacelab

    Science.gov (United States)

    Savage, P. D., Jr.; Dalton, B.; Hogan, R.; Leon, H.

    1991-01-01

    Report describes experiments done as part of Spacelab Life Sciences 2 mission (SLS-2). Research planned on cardiovascular, vestibular, metabolic, and thermal responses of animals in weightlessness. Expected to shed light on effects of prolonged weightlessness on humans.

  7. Spacelab Mission Implementation Cost Assessment (SMICA)

    Science.gov (United States)

    Guynes, B. V.

    1984-01-01

    A total savings of approximately 20 percent is attainable if: (1) mission management and ground processing schedules are compressed; (2) the equipping, staffing, and operating of the Payload Operations Control Center is revised, and (3) methods of working with experiment developers are changed. The development of a new mission implementation technique, which includes mission definition, experiment development, and mission integration/operations, is examined. The Payload Operations Control Center is to relocate and utilize new computer equipment to produce cost savings. Methods of reducing costs by minimizing the Spacelab and payload processing time during pre- and post-mission operation at KSC are analyzed. The changes required to reduce costs in the analytical integration process are studied. The influence of time, requirements accountability, and risk on costs is discussed. Recommendation for cost reductions developed by the Spacelab Mission Implementation Cost Assessment study are listed.

  8. Animal experimentation in Spacelab - Present and future U.S. plans

    Science.gov (United States)

    Berry, W. E.; Dant, C. C.

    1983-01-01

    Current development of life-sciences hardware and experiments for the fourth Spacelab mission in the Life Sciences Flight Experiments Program at NASA Ames is reviewed. The research-animal holding facility, the general-purpose work station, and the life sciences laboratory equipment are characterized, and the 14 Ames projects accepted for the mission are listed and discussed. Several hardware systems and experimental procedures will be verified on the Spacelab-3 mission scheduled for late 1984.

  9. The astronomy spacelab payloads study: executive volume. Interim report

    International Nuclear Information System (INIS)

    1975-07-01

    The progress of the Astronomy Spacelab Payloads Project at the Goddard Space Flight Center is reported. Astronomical research in space, using the Spacelab in conjunction with the Space Shuttle, is described. The various fields of solar astronomy or solar physics, ultraviolet and optical astronomy, and high energy astrophysics are among the topics discussed. These fields include scientific studies of the Sun and its dynamical processes, of the stars in wavelength regions not accessible to ground based observations, and the exciting new fields of X-ray, gamma ray, and particle astronomy

  10. Tiangong-1, the First Manned Spacelab of China

    Science.gov (United States)

    Coue, P.

    This paper presents an overview of Tiangong-1, the first Chinese space station officially dubbed Spacelab by Beijing authorities. Tiangong programme also demonstrates the actual progress level of China in the field of manned space activities. This new spacecraft will allow China to practice many tasks, to help prepare for the next step: the permanently occupied space station. Open sources have been only used to write this paper. For example, Chinese media revealed numerous information describing the Spacelab during the first docking operation between Tiangong-1 and Shenzhou-8. All aspects of this programme will be listed comprising the old stories and the new one: major technical characteristics, accommodation, mission, future prospects, etc.

  11. Plasma diagnostics package. Volume 2: Spacelab 2 section. Part B: Thesis projects. Final science report

    International Nuclear Information System (INIS)

    Pickett, J.S.; Frank, L.A.; Kurth, W.S.

    1988-06-01

    This volume (2), which consists of two parts (A and B), of the Plasma Diagnostics Package (PDP) Final Science Report contains a summary of all of the data reduction and scientific analyses which were performed using PDP data obtained on STS-51F as a part of the Spacelab 2 (SL-2) payload. This work was performed during the period of launch, July 29, 1985, through June 30, 1988. During this period the primary data reduction effort consisted of processing summary plots of the data received by 12 of the 14 instruments located on the PDP and submitting these data to the National Space Science Data Center (NSSDC). Three Master's and three Ph.D. theses were written using PDP instrumentation data. These theses are listed in Volume 2, Part B

  12. Dedicated data recording video system for Spacelab experiments

    Science.gov (United States)

    Fukuda, Toshiyuki; Tanaka, Shoji; Fujiwara, Shinji; Onozuka, Kuniharu

    1984-04-01

    A feasibility study of video tape recorder (VTR) modification to add the capability of data recording etc. was conducted. This system is an on-broad system to support Spacelab experiments as a dedicated video system and a dedicated data recording system to operate independently of the normal operation of the Orbiter, Spacelab and the other experiments. It continuously records the video image signals with the acquired data, status and operator's voice at the same time on one cassette video tape. Such things, the crews' actions, animals' behavior, microscopic views and melting materials in furnace, etc. are recorded. So, it is expected that experimenters can make a very easy and convenient analysis of the synchronized video, voice and data signals in their post flight analysis.

  13. AMPS sciences objectives and philosophy. [Atmospheric, Magnetospheric and Plasmas-in-Space project on Spacelab

    Science.gov (United States)

    Schmerling, E. R.

    1975-01-01

    The Space Shuttle will open a new era in the exploration of earth's near-space environment, where the weight and power capabilities of Spacelab and the ability to use man in real time add important new features. The Atmospheric, Magnetospheric, and Plasmas-in-Space project (AMPS) is conceived of as a facility where flexible core instruments can be flown repeatedly to perform different observations and experiments. The twin thrusts of remote sensing of the atmosphere below 120 km and active experiments on the space plasma are the major themes. They have broader implications in increasing our understanding of plasma physics and of energy conversion processes elsewhere in the universe.

  14. Effects of rectilinear acceleration, caloric and optokinetic stimulation of human subjects in the Spacelab D-1 mission

    Science.gov (United States)

    Wetzig, J.; von Baumgarten, R.

    A set of vestibular experiments was performed during the course of the German Spacelab D-1 mission from 30 October to 6 November 1985 by a consortium of experimenters from various european countries. Similar to the Spacelab SL-1 mission all of the scientific crew members were theoretically and practically trained for the experiments. Baseline measurements for all tests were collected 113, 86, 44, 30 and 18 days prior to the mission and compared with data taken inflight, on the landing day and the consecutive 7 to 14 days. The hardware comprised mainly a motordriven accelerating platform, the SPACE SLED, and the vestibular helmet, a multi-purpose instrument in support of a variety of vestibular experiments including air-calorisation of the ears, optokinetic stimulation pattern presentation and optical and nystagmographic recording of eye movements. Measurements of the threshold for the perception of detection of whole body movement did not reveal any dramatic changes in the 2 measured axes inflight when compared to preflight values. Early postflight values show a significantly elevated threshold for all axes in 3 out of 4 subjects. The caloric nystagmus, already found during the SL-1 mission, was confirmed on all three tested subjects during the D-1 mission. It's amplitude and in some instances it's direction were influenced by horizontal acceleration on the SLED. The amplitude of optokinetic nystagmus increased when subjects were allowed to free-float over that seen when subjects were fixed. Stimulation of the neck receptors by roll movements of the body against the fixated head resulted in illusory object motion to the contralateral side. Torsional movements of the eyes during such neck receptor stimulation was present inflight and postflight, while it had not been observed preflight. Most results point to a reduction of otolithic effects in favour of visual and proprioceptive influences for spatial orientation.

  15. Noise evaluation of a point autofocus surface topography measuring instrument

    Science.gov (United States)

    Maculotti, Giacomo; Feng, Xiaobing; Galetto, Maurizio; Leach, Richard

    2018-06-01

    In this work, the measurement noise of a point autofocus surface topography measuring instrument is evaluated, as the first step towards establishing a route to traceability for this type of instrument. The evaluation is based on the determination of the metrological characteristics for noise as outlined in draft ISO specification standards by using a calibrated optical flat. The static noise and repeatability of the autofocus sensor are evaluated. The influence of environmental disturbances on the measured surface topography and the built-in software to compensate for such influences are also investigated. The instrument was found to have a measurement noise of approximately 2 nm or, when expressed with the measurement bandwidth, 0.4 nm for a single-point measurement.

  16. Definition of Life Sciences laboratories for shuttle/Spacelab. Volume 1: Executive summary

    Science.gov (United States)

    1975-01-01

    Research requirements and the laboratories needed to support a Life Sciences research program during the shuttle/Spacelab era were investigated. A common operational research equipment inventory was developed to support a comprehensive but flexible Life Sciences program. Candidate laboratories and operational schedules were defined and evaluated in terms of accomodation with the Spacelab and overall program planning. Results provide a firm foundation for the initiation of a life science program for the shuttle era.

  17. International aerospace engineering: NASA shuttle and European Spacelab

    Science.gov (United States)

    Bilstein, R. E.

    1981-01-01

    NASA negotiations and contractual arrangements involving European space research organizations' participation in manned space operations and efforts in building Spacelab for the U.S. Reusable Space Shuttle are discussed. Some of the diplomatic and technical collaboration involved in the international effort is reviewed.

  18. Design features of selected mechanisms developed for use in Spacelab. [mechanical ground support equipment and environmental control

    Science.gov (United States)

    Inden, W.

    1979-01-01

    Selected mechanisms developed for the Spacelab program are discussed. These include: (1) the roller rail used to install/remove the Spacelab floor loaded with racks carrying experiments; (2) the foot restraint; and (3) the lithium hydroxide used for decontamination.

  19. Mental Workload and Performance Experiment (MWPE) Team in the Spacelab Payload Operations Control

    Science.gov (United States)

    1992-01-01

    The primary payload for Space Shuttle Mission STS-42, launched January 22, 1992, was the International Microgravity Laboratory-1 (IML-1), a pressurized manned Spacelab module. The goal of IML-1 was to explore in depth the complex effects of weightlessness of living organisms and materials processing. Around-the-clock research was performed on the human nervous system's adaptation to low gravity and effects of microgravity on other life forms such as shrimp eggs, lentil seedlings, fruit fly eggs, and bacteria. Materials processing experiments were also conducted, including crystal growth from a variety of substances such as enzymes, mercury iodide, and a virus. The Huntsville Operations Support Center (HOSC) Spacelab Payload Operations Control Center (SL POCC) at the Marshall Space Flight Center (MSFC) was the air/ground communication channel used between the astronauts and ground control teams during the Spacelab missions. Featured is the Mental Workload and Performance Experiment (MWPE) team in the SL POCC) during STS-42, IML-1 mission.

  20. Optoelectronic Capillary Sensors in Microfluidic and Point-of-Care Instrumentation

    Directory of Open Access Journals (Sweden)

    Michał Borecki

    2010-04-01

    Full Text Available This paper presents a review, based on the published literature and on the authors’ own research, of the current state of the art of fiber-optic capillary sensors and related instrumentation as well as their applications, with special emphasis on point-of-care chemical and biochemical sensors, systematizing the various types of sensors from the point of view of the principles of their construction and operation. Unlike classical fiber-optic sensors which rely on changes in light propagation inside the fiber as affected by outside conditions, optical capillary sensors rely on changes of light transmission in capillaries filled with the analyzed liquid, which opens the possibility of interesting new applications, while raising specific issues relating to the construction, materials and instrumentation of those sensors.

  1. Holography on the Spacelab 3 mission

    Science.gov (United States)

    Owen, Robert B.; Kroes, R. L.

    1985-01-01

    Spacelab 3's Fluid Experiment System, in which triglycine sulfate crystals were produced by a low temperature solution-growth technique, employs holography as its primary data-gathering system. This use of holography allows optical techniques which would be difficult to apply in orbit to be used after the holographic data is returned to ground laboratories, using an analysis of the reconstructed holographic image. The system used allows both single- and double-exposure holograms to be obtained in two separate orthogonal configurations.

  2. Gravity Plant Physiology Facility (GPPF) Team in the Spacelab Payload Operations Control Center (SL

    Science.gov (United States)

    1992-01-01

    The primary payload for Space Shuttle Mission STS-42, launched January 22, 1992, was the International Microgravity Laboratory-1 (IML-1), a pressurized manned Spacelab module. The goal of IML-1 was to explore in depth the complex effects of weightlessness of living organisms and materials processing. Around-the-clock research was performed on the human nervous system's adaptation to low gravity and effects of microgravity on other life forms such as shrimp eggs, lentil seedlings, fruit fly eggs, and bacteria. Materials processing experiments were also conducted, including crystal growth from a variety of substances such as enzymes, mercury iodide, and a virus. The Huntsville Operations Support Center (HOSC) Spacelab Payload Operations Control Center (SL POCC) at the Marshall Space Flight Center (MSFC) was the air/ground communication channel used between the astronauts and ground control teams during the Spacelab missions. Featured is the Gravity Plant Physiology Facility (GPPF) team in the SL POCC during the IML-1 mission.

  3. The design and development of an oil-free compressor for Spacelab Refrigerator/Freezer

    Science.gov (United States)

    Hye, A.

    1984-01-01

    Design features and test results of an oil-free compressor developed for Spacelab Mission-4 Refrigerator/Freezer are detailed. The compressor has four identical pistons activated by a common eccentric shaft, operated by a brushless dc motor at 1300 rpm. The stroke of each piston is 0.28 cm, with the piston ends connected to the shaft by means of sealed needle bearings, eliminating the ned for oil. The mass flow rates produced by the compressor are by over 100 percent higher compared to the original Amfridge unit. Test results show that the compressor can meet the Spacelab refrigerator/freezer requirements.

  4. Spacelab Life Science-1 Mission Onboard Photograph

    Science.gov (United States)

    1995-01-01

    Spacelab Life Science -1 (SLS-1) was the first Spacelab mission dedicated solely to life sciences. The main purpose of the SLS-1 mission was to study the mechanisms, magnitudes, and time courses of certain physiological changes that occur during space flight, to investigate the consequences of the body's adaptation to microgravity and readjustment to Earth's gravity, and bring the benefits back home to Earth. The mission was designed to explore the responses of the heart, lungs, blood vessels, kidneys, and hormone-secreting glands to microgravity and related body fluid shifts; examine the causes of space motion sickness; and study changes in the muscles, bones, and cells. This photograph shows astronaut Rhea Seddon conducting an inflight study of the Cardiovascular Deconditioning experiment by breathing into the cardiovascular rebreathing unit. This experiment focused on the deconditioning of the heart and lungs and changes in cardiopulmonary function that occur upon return to Earth. By using noninvasive techniques of prolonged expiration and rebreathing, investigators can determine the amount of blood pumped out of the heart (cardiac output), the ease with which blood flows through all the vessels (total peripheral resistance), oxygen used and carbon dioxide released by the body, and lung function and volume changes. SLS-1 was launched aboard the Space Shuttle Orbiter Columbia (STS-40) on June 5, 1995.

  5. Mechanical and thermal design of an experiment aboard the space shuttle: the Spacelab spectrometer

    International Nuclear Information System (INIS)

    Besson, J.

    1985-01-01

    The spectrometer designed by ONERA and IASB (Belgium Space Aeronomy Institute) to measure atmospheric trace constituents was flown aboard Spacelab 1 during the 9 th mission of the American Space Shuttle from November 28 to December 8, 1983. After a brief summary of the history of the project related to Spacelab, the mechanical and thermal design of the spectrometer is described. Some methods, calculations and characteristic tests are detailed as examples. The behaviour of the experiment during the mission and the results of the post-flight tests are shortly analyzed in order to prepare the qualification for a reflight [fr

  6. The Hinkley point 'B' instrumented stringer data logger

    International Nuclear Information System (INIS)

    Beynon, A.J.

    1975-10-01

    A computer based data logging system has been installed at Hinkley Point 'B'to accumulate and interpret data from instrumented stringers in Reactor 4. The logger has 90 thermocouple and 10 pressure transducer inputs, and is backed up by a manually operated system. Details of the logger and instructions in its use for anyone unfamiliar with it are given. Self-contained descriptions of each computer program, covering routine data acquisition and special purpose programs for measuring transient behaviour are then presented. (author)

  7. The gravitational plant physiology facility-Description of equipment developed for biological research in spacelab

    Science.gov (United States)

    Heathcote, D. G.; Chapman, D. K.; Brown, A. H.; Lewis, R. F.

    1994-01-01

    In January 1992, the NASA Suttle mission STS 42 carried a facility designed to perform experiments on plant gravi- and photo-tropic responses. This equipment, the Gravitational Plant Physiology Facility (GPPF) was made up of a number of interconnected units mounted within a Spacelab double rack. The details of these units and the plant growth containers designed for use in GPPF are described. The equipment functioned well during the mission and returned a substantial body of time-lapse video data on plant responses to tropistic stimuli under conditions of orbital microgravity. GPPF is maintained by NASA Ames Research Center, and is flight qualifiable for future spacelab missions.

  8. Spacelab life sciences 2 post mission report

    Science.gov (United States)

    Buckey, Jay C.

    1994-01-01

    Jay C. Buckey, M.D., Assistant Professor of Medicine at The University of Texas Southwestern Medical Center at Dallas served as an alternate payload specialist astronaut for the Spacelab Life Sciences 2 Space Shuttle Mission from January 1992 through December 1993. This report summarizes his opinions on the mission and offers suggestions in the areas of selection, training, simulations, baseline data collection and mission operations. The report recognizes the contributions of the commander, payload commander and mission management team to the success of the mission. Dr. Buckey's main accomplishments during the mission are listed.

  9. Life sciences payload definition and integration study. Volume 1: Executive summary. [carry-on laboratory for Spacelab

    Science.gov (United States)

    1974-01-01

    The definition and integration tasks involved in the development of design concepts for a carry-on laboratory (COL), to be compatible with Spacelab operations, were divided into the following study areas: (1) identification of research and equipment requirements of the COL; (2) development of a number of conceptual layouts for COL based on the defined research of final conceptual designs; and (4) development of COL planning information for definition of COL/Spacelab interface data, cost data, and program cost schedules, including design drawings of a selected COL to permit fabrication of a functional breadboard.

  10. Spacelab Level 4 Programmatic Implementation Assessment Study. Volume 2: Ground Processing requirements

    Science.gov (United States)

    1978-01-01

    Alternate ground processing options are summarized, including installation and test requirements for payloads, space processing, combined astronomy, and life sciences. The level 4 integration resource requirements are also reviewed for: personnel, temporary relocation, transportation, ground support equipment, and Spacelab flight hardware.

  11. Low power CAMAC and NIM modular systems for spaceflight use on Shuttle and Spacelab missions

    Energy Technology Data Exchange (ETDEWEB)

    Trainor, J.H.; Kaminski, T.J.; Ehrmann, C.H.

    1977-02-01

    The advent of the Shuttle launch vehicle and Spacelab have resulted in adequate weight and volume such that experiment electronics can be implemented at relatively low cost using spaceflight versions of CAMAC and NIM modules. Studies of 10 modules by manufacturers have shown that power reduction overall by a factor of approximately 3 can be accomplished. This is adequate both from the point of view of consumption and temperature rise in vacuum. Our studies have shown that a stock of approximately 45 module types is required and a listing is given. The changes required in these modules in order to produce spaceflight versions are described. And finally, the further studies, prototyping and testing leading to eventual flight qualification are described.

  12. Evaluation of biological models using Spacelab

    Science.gov (United States)

    Tollinger, D.; Williams, B. A.

    1980-01-01

    Biological models of hypogravity effects are described, including the cardiovascular-fluid shift, musculoskeletal, embryological and space sickness models. These models predict such effects as loss of extracellular fluid and electrolytes, decrease in red blood cell mass, and the loss of muscle and bone mass in weight-bearing portions of the body. Experimentation in Spacelab by the use of implanted electromagnetic flow probes, by fertilizing frog eggs in hypogravity and fixing the eggs at various stages of early development and by assessing the role of the vestibulocular reflex arc in space sickness is suggested. It is concluded that the use of small animals eliminates the uncertainties caused by corrective or preventive measures employed with human subjects.

  13. Contemporary achievements in astronautics: Salyut-7, the Vega Project and Spacelab

    Science.gov (United States)

    Kubasov, V. N.; Balebanov, V. M.; Goldovskiy, D. Y.

    1986-01-01

    The latest achievements in Soviet aeronautics are described; the new stage in the space program to study Venus using Soviet automated space probes, and the next space mission by cosmonauts to the Salyut-7 station. Information is also presented on the flight of the Spacelab orbiting laboratory created by Western European specialists.

  14. The Spacelab-Mir-1 "Greenhouse-2" experiment

    Science.gov (United States)

    Bingham, G. E.; Salisbury, F. B.; Campbell, W. F.; Carman, J. G.; Bubenheim, D. L.; Yendler, B.; Sytchev, V. N.; Levinskikh, M. A.; Podolsky, I. G.

    1996-01-01

    The Spacelab-Mir-1 (SLM-1) mission is the first docking of the Space Shuttle Atlantis (STS-71) with the Orbital Station Mir in June 1995. The SLM-1 "Greenhouse-2" experiment will utilize the Russian-Bulgarian-developed plant growth unit (Svet). "Greenhouse-2" will include two plantings (1) designed to test the capability of Svet to grow a crop of Superdwarf wheat from seed to seed, and (2) to provide green plant material for post-flight analysis. Protocols, procedures, and equipment for the experiment have been developed by the US-Russian science team. "Greenhouse-2" will also provide the first orbital test of a new Svet Instrumentation System (SIS) developed by Utah State University to provide near real time data on plant environmental parameters and gas-exchange rates. SIS supplements the Svet control and monitoring system with additional sensors for substrate moisture, air temperature, IR leaf temperature, light, oxygen, pressure, humidity, and carbon-dioxide. SIS provides the capability to monitor canopy transpiration and net assimilation of the plants growing in each vegetation unit (root zone) by enclosing the canopy in separate, retractable, ventilated leaf chambers. Six times during the seed-to-seed experiment, plant samples will be collected, leaf area measured, and plant parts fixed and/or dried for ground analysis. A second planting initiated 30 days before the arrival of a U.S. Shuttle [originally planned to be STS-71] is designed to provide green material at the vegetative development stage for ground analysis. [As this paper is being edited, the experiment has been delayed until after the arrival of STS-71.].

  15. The Evolution of Spacelab Ultraviolet Astronomy Missions from OSS-3 through -7 to Astro-1

    Science.gov (United States)

    Gull, Theodore

    2018-01-01

    In the 1960s and 1970s, NASA was building towards a robust program in space astronomy. An evolutionary step from ground-based astronomy to space astronomy was human operation of space telescopes as astronomy in general evolved from astronomers directly at the telescope to application of computers and long distance communications to control to operate remote telescopes. Today ground-based telescopes and space observatories from cubesats to the Hubble Space Telescope and soon the James Webb Space Telescope are routinely operated remotely.In response to the Spacelab Announcement of Opportunity in the early 1980s, three ultraviolet experiments – the Hopkins Ultraviolet Telescope, the Ultraviolet Imaging Telescope and the Wisconsin Ultraviolet PhotoPolarimetry Experiment -- all instruments derived from multiple sounding rocket flights--were selected to fly as an integrated payload attached to a space shuttle. The justification for professional astronomers, both as Mission Specialists from the astronaut cadre and Payload Specialists from the instrument teams, was built to ensure key technical skills both of the science and the instruments. Bundled together as OSS-3 through -7 flights focused on Comet Halley, the experiments went through many changes and delays as a pathfinder for an anticipated series of attached astronomy payloads.By 1986, the five-flight mission had evolved into two missions, Astro-1 dedicated primarily to observe Halley’s Comet in early March 1986 and Astro-2 to fly about one year later. Due to the Challenger disaster 35 days before scheduled launch of Astro-1, the mission went through an initial cancellation and then re-scheduling once the instrument complement of Astro-1 was expanded to include Broad Band X-ray Telescope with emphasis on studying SN1987A. Ultimately Astro-1 flew in December 1990 partnered with an X-ray experiment focused on SN1987A.The nine-day mission was mostly successful despite multiple technical issues overcome by the NASA

  16. Spacelab - Ten years of international cooperation

    Science.gov (United States)

    Bignier, M.; Harrington, J. C.; Sander, M. J.

    1983-01-01

    The history, current status, and future plans of the Spacelab program are reviewed, with a focus on the cooperative relationship between ESA and NASA. The initial decision to undertake the program and the three agreements signed to begin its implementation are examined, and the division of responsibilities and financial contributions is discussed insofar as it affected the management structure. Consideration is given to the major facilities, the 50-mission operational cycle, communications, the currently scheduled activities (through 1985), the prospective later uses, and the ten dedicated discipline laboratories. The importance of continuous mutual support during the planning and development phases is stressed. The program so far is considered a success, in terms of the goals set by the participants and in terms of the resolution of the problems inherent in international technological endeavors.

  17. Protection Spacelab from Meteoroid and Orbital Debris

    Science.gov (United States)

    Zheng, Shigui; Yan, Jun; Han, Zengyao

    2013-08-01

    As the first long-term on-orbit spacelab of China, TianGong-1 will stay aloft for 2 years. Its failure risk subjected to Meteoroid and Orbital Debris(M/OD) is hundreds of times higher than the risk of Shenzhou-5, Shenzhou-6 or Shenzhou-7, so the special M/OD protection designs have been applied. In order to reduce the penetration risk of radiator tube, the design of radiator has been modified by placing the tube at the side of radiator plate, and the new design does not affect the thermal control system without adding the mass. Secondly, Whipple structure is adopted in the two sides and front of spacecraft against M/OD impact.

  18. Animal studies on Spacelab-3

    Science.gov (United States)

    Schatte, C.; Grindeland, R.; Callahan, P.; Berry, W.; Funk, G.; Lencki, W.

    1987-01-01

    The flight of two squirrel monkeys and 24 rats on Spacelab-3 was the first mission to provide hands-on maintenance on animals in a laboratory environment. With few exceptions, the animals grew and behaved normally, were free of chronic stress, and differed from ground controls only for gravity dependent parameters. One of the monkeys exhibited symptoms of space sickness similar to those observed in humans, which suggests squirrel monkeys may be good models for studying the space adaptation syndrome. Among the wide variety of parameters measured in the rats, most notable was the dramatic loss of muscle mass and increased fragility of long bones. Other interesting rat findings were those of suppressed interferom production by spleen cells, defective release of growth hormone by somatrophs, possible dissociation of circadian pacemakers, changes in hepatic lipid and carbohydrate metabolism, and hypersensitivity of marrow cells to erythropoietin. These results portend a strong role for animals in identifying and elucidating the physiological and anatomical responses of mammals to microgravity.

  19. Improved waste water vapor compression distillation technology. [for Spacelab

    Science.gov (United States)

    Johnson, K. L.; Nuccio, P. P.; Reveley, W. F.

    1977-01-01

    The vapor compression distillation process is a method of recovering potable water from crewman urine in a manned spacecraft or space station. A description is presented of the research and development approach to the solution of the various problems encountered with previous vapor compression distillation units. The design solutions considered are incorporated in the preliminary design of a vapor compression distillation subsystem. The new design concepts are available for integration in the next generation of support systems and, particularly, the regenerative life support evaluation intended for project Spacelab.

  20. Extracting Loop Bounds for WCET Analysis Using the Instrumentation Point Graph

    Science.gov (United States)

    Betts, A.; Bernat, G.

    2009-05-01

    Every calculation engine proposed in the literature of Worst-Case Execution Time (WCET) analysis requires upper bounds on loop iterations. Existing mechanisms to procure this information are either error prone, because they are gathered from the end-user, or limited in scope, because automatic analyses target very specific loop structures. In this paper, we present a technique that obtains bounds completely automatically for arbitrary loop structures. In particular, we show how to employ the Instrumentation Point Graph (IPG) to parse traces of execution (generated by an instrumented program) in order to extract bounds relative to any loop-nesting level. With this technique, therefore, non-rectangular dependencies between loops can be captured, allowing more accurate WCET estimates to be calculated. We demonstrate the improvement in accuracy by comparing WCET estimates computed through our HMB framework against those computed with state-of-the-art techniques.

  1. Concentrations of ethane (C2H6) in the lower stratosphere and upper troposphere and acetylene (C2H2) in the upper troposphere deduced from Atmospheric Trace Molecule Spectroscopy/Spacelab 3 spectra

    Science.gov (United States)

    Rinsland, C. P.; Russell, J. M., III; Zander, R.; Farmer, C. B.; Norton, R. H.

    1987-01-01

    This paper reports the results of the spectroscopic analysis of C2H6 and C2H2 absorption spectra obtained by the Atmospheric Trace Molecule Spectroscopy (ATMOS) instrument flown on the Shuttle as part of the Spacelab 3 mission. The spectra were recorded during sunset occultations occurring between 25 deg N and 31 deg N latitudes, yielding volume-mixing ratio profiles of C2H6 in the lower stratosphere and the upper troposphere, and an upper tropospheric profile of C2H2. These results compare well with previous in situ and remote sounding data obtained at similar latitudes and with model calculations. The results demonstrate the feasibility of the ATMOS instrument to sound the lower atmosphere from space.

  2. Preliminary results of the Spacelab 2 superfluid helium experiment

    International Nuclear Information System (INIS)

    Mason, P.V.; Collins, D.J.; Elleman, D.D.; Jackson, H.W.; Wang, T.

    1986-01-01

    An experiment to investigate the properties of superfluid helium in a microgravity environment flew on the Shuttle on the Spacelab 2 mission in July and August of 1985. This paper summarizes the flight experiment and describes some preliminary results. The experiment comprised an investigation of long-wavelength third-sound waves in micron-thick films, a study of the motions of superfluid helium under milli-g and micro-g accelerations, and measurements of the fluctuations in temperature associated with the small motions of the bulk helium. An additional objective was to qualify and characterize a reflyable, space-compatible cryostat

  3. Multi point of care instrument evaluation for use in anti-retroviral clinics in South Africa.

    Science.gov (United States)

    Gounden, Verena; George, Jaya

    2012-01-01

    South Africa has the largest prevalence of HIV infected individuals in the world. The introduction of point of care testing to anti-retroviral (ARV) clinic sites is hoped to fast track initiation of patients on ARVs and to allow for earlier recognition of adverse effects such as dyslipidaemia, renal and hepatic dysfunction. We evaluated six instruments for the following analytes: glucose, lactate, creatinine, cholesterol, triglycerides, HDL-cholesterol, alanine transaminase (ALT), and glycated haemoglobin. Comparisons with the central laboratory analyser were performed as well as precision studies. A scoring system was developed by the authors to evaluate the instruments in terms of analytical performance, cost, ease of use, and other operational characteristics. As one of the goals of the placement of these instruments was that their operation was simple enough to be used by non-laboratory staff, ease of use contributed a large proportion to the final scoring. Analytical performance of the POC analysers were generally similar, however, there were significant differences in operational characteristics and ease of use. Bias for the different analytes when compared to the laboratory analyser ranged from -27% to 14%. Calculated total errors for all analytes except for HDL cholesterol were within total allowable error recommendations. The two instruments (Roche Reflotron and Cholestech LDX) with the highest overall total points achieved the highest scores for ease of use. This pilot study has led to the development of a scoring system for the evaluation of POC instruments.

  4. Hematology and biochemical findings of Spacelab 1 flight

    Science.gov (United States)

    Leach, Carolyn S.; Chen, J. P.; Crosby, W.; Johnson, P. C.; Lange, R. D.; Larkin, E.; Tavassoli, M.

    1988-01-01

    The changes in erythropoiesis in astronauts caused by weightlessness was experimentally studied during the Spacelab 1 flight. Immediately after landing showed a mean decrease of 9,3 percent in the four astronauts. Neither hyperoxia nor an increase in blood phosphate caused the decrease. Red cell survival time and iron incorporation postflight were not significantly different from their preflight levels. Serum haptoglobin did not decrease, indicating that intravascular hemolysis was not a major cause of red cell mass change. An increase in serum ferritin after the second day of flight may have been caused by red cell breakdown early in flight. The space flight-induced decrease in red cell mass may result from a failure of erythropoesis to replace cells destroyed by the spleen soon after weightlessness is attained.

  5. Plasma diagnostics package. Volume 2: Spacelab 2 section, part A

    Science.gov (United States)

    Pickett, Jolene S. (Compiler); Frank, L. A. (Compiler); Kurth, W. S. (Compiler)

    1988-01-01

    This volume (2), which consists of two parts (A and B), of the Plasma Diagnostics Package (PDP) Final Science Report contains a summary of all of the data reduction and scientific analyses which were performed using PDP data obtained on STS-51F as a part of the Spacelab 2 (SL-2) payload. This work was performed during the period of launch, July 29, l985, through June 30, l988. During this period the primary data reduction effort consisted of processing summary plots of the data received by 12 of the 14 instruments located on the PDP and submitting these data to the National Space Science Data Center (NSSDC). The scientific analyses during the performance period consisted of follow-up studies of shuttle orbiter environment and orbiter/ionosphere interactions and various plasma particle and wave studies which dealt with data taken when the PDP was on the Remote Manipulator System (RMS) arm and when the PDP was in free flight. Of particular interest during the RMS operations and free flight were the orbiter wake studies and joint studies of beam/plasma interactions with the SL-2 Fast Pulse Electron Generator (FPEG) of the Vehicle Charging and Potential Investigation (VCAP). Internal reports, published papers and presentations which involve PDP/SL-2 data are listed in Sections 3 and 4. A PDP/SL-2 scientific results meeting was held at the University of Iowa on June 10, l986. This meeting was attended by most of the PDP and VCAP investigators and provided a forum for discussing and comparing the various results, particularly with regard to the PDP free flight.

  6. The design, fabrication and installation of cable routing mockups in support of Spacelab 2

    Science.gov (United States)

    1981-01-01

    From flight and mockup drawings of Spacelab 2 (SL 2) experiments and hardware, shop ready mockup drawings were produced. Floor panels were the first items considered for fabrication. Cold plate and orthogrid mockups were designed and fabricated. Experiment and other hardware mockups were fabricated of aluminum or plywood, depending on size and configuration. Eighty-three cable routing bracket mockups were fabricated of aluminum and delivered for painting.

  7. An ultra-precision tool nanoindentation instrument for replication of single point diamond tool cutting edges

    Science.gov (United States)

    Cai, Yindi; Chen, Yuan-Liu; Xu, Malu; Shimizu, Yuki; Ito, So; Matsukuma, Hiraku; Gao, Wei

    2018-05-01

    Precision replication of the diamond tool cutting edge is required for non-destructive tool metrology. This paper presents an ultra-precision tool nanoindentation instrument designed and constructed for replication of the cutting edge of a single point diamond tool onto a selected soft metal workpiece by precisely indenting the tool cutting edge into the workpiece surface. The instrument has the ability to control the indentation depth with a nanometric resolution, enabling the replication of tool cutting edges with high precision. The motion of the diamond tool along the indentation direction is controlled by the piezoelectric actuator of a fast tool servo (FTS). An integrated capacitive sensor of the FTS is employed to detect the displacement of the diamond tool. The soft metal workpiece is attached to an aluminum cantilever whose deflection is monitored by another capacitive sensor, referred to as an outside capacitive sensor. The indentation force and depth can be accurately evaluated from the diamond tool displacement, the cantilever deflection and the cantilever spring constant. Experiments were carried out by replicating the cutting edge of a single point diamond tool with a nose radius of 2.0 mm on a copper workpiece surface. The profile of the replicated tool cutting edge was measured using an atomic force microscope (AFM). The effectiveness of the instrument in precision replication of diamond tool cutting edges is well-verified by the experimental results.

  8. Life science payloads planning study. [for space shuttle orbiters and spacelab

    Science.gov (United States)

    Nelson, W. G.; Wells, G. W.

    1977-01-01

    Preferred approaches and procedures were defined for integrating the space shuttle life sciences payload from experiment solicitation through final data dissemination at mission completion. The payloads operations plan was refined and expended to include current information. The NASA-JSC facility accommodations were assessed, and modifications recommended to improve payload processing capability. Standard format worksheets were developed to permit rapid location of experiment requirements and a Spacelab mission handbook was developed to assist potential life sciences investigators at academic, industrial, health research, and NASA centers. Practical, cost effective methods were determined for accommodating various categories of live specimens during all mission phases.

  9. Final definition and preliminary design study for the initial atmospheric cloud physics laboratory, a spacelab mission payload

    Science.gov (United States)

    1976-01-01

    The Atmospheric Cloud Physics Laboratory (ACPL) task flow is shown. Current progress is identified. The requirements generated in task 1 have been used to formulate an initial ACPL baseline design concept. ACPL design/functional features are illustrated. A timetable is presented of the routines for ACPL integration with the spacelab system.

  10. Development of user guidelines for ECAS display design. Volume 2: Tasks 9 and 10. [educating the public to the benefits of spacelab and the space transportation system

    Science.gov (United States)

    Bathurst, D. B.

    1979-01-01

    Lay-oriented speakers aids, articles, a booklet, and a press kit were developed to inform the press and the general public with background information on the space transportation system, Spacelab, and Spacelab 1 experiments. Educational materials relating to solar-terrestrial physics and its potential benefits to mankind were also written. A basic network for distributing audiovisual and printed materials to regional secondary schools and universities was developed. Suggested scripts to be used with visual aids describing materials science and technology and astronomy and solar physics are presented.

  11. An interactive computer approach to performing resource analysis for a multi-resource/multi-project problem. [Spacelab inventory procurement planning

    Science.gov (United States)

    Schlagheck, R. A.

    1977-01-01

    New planning techniques and supporting computer tools are needed for the optimization of resources and costs for space transportation and payload systems. Heavy emphasis on cost effective utilization of resources has caused NASA program planners to look at the impact of various independent variables that affect procurement buying. A description is presented of a category of resource planning which deals with Spacelab inventory procurement analysis. Spacelab is a joint payload project between NASA and the European Space Agency and will be flown aboard the Space Shuttle starting in 1980. In order to respond rapidly to the various procurement planning exercises, a system was built that could perform resource analysis in a quick and efficient manner. This system is known as the Interactive Resource Utilization Program (IRUP). Attention is given to aspects of problem definition, an IRUP system description, questions of data base entry, the approach used for project scheduling, and problems of resource allocation.

  12. On-site meteorological instrumentation requirements to characterize diffusion from point sources: workshop report. Final report Sep 79-Sep 80

    International Nuclear Information System (INIS)

    Strimaitis, D.; Hoffnagle, G.; Bass, A.

    1981-04-01

    Results of a workshop entitled 'On-Site Meteorological Instrumentation Requirements to Characterize Diffusion from Point Sources' are summarized and reported. The workshop was sponsored by the U.S. Environmental Protection Agency in Raleigh, North Carolina, on January 15-17, 1980. Its purpose was to provide EPA with a thorough examination of the meteorological instrumentation and data collection requirements needed to characterize airborne dispersion of air contaminants from point sources and to recommend, based on an expert consensus, specific measurement technique and accuracies. Secondary purposes of the workshop were to (1) make recommendations to the National Weather Service (NWS) about collecting and archiving meteorological data that would best support air quality dispersion modeling objectives and (2) make recommendations on standardization of meteorological data reporting and quality assurance programs

  13. Dynamic cell culture system: a new cell cultivation instrument for biological experiments in space

    Science.gov (United States)

    Gmunder, F. K.; Nordau, C. G.; Tschopp, A.; Huber, B.; Cogoli, A.

    1988-01-01

    The prototype of a miniaturized cell cultivation instrument for animal cell culture experiments aboard Spacelab is presented (Dynamic cell culture system: DCCS). The cell chamber is completely filled and has a working volume of 200 microliters. Medium exchange is achieved with a self-powered osmotic pump (flowrate 1 microliter h-1). The reservoir volume of culture medium is 230 microliters. The system is neither mechanically stirred nor equipped with sensors. Hamster kidney (Hak) cells growing on Cytodex 3 microcarriers were used to test the biological performance of the DCCS. Growth characteristics in the DCCS, as judged by maximal cell density, glucose consumption, lactic acid secretion and pH, were similar to those in cell culture tubes.

  14. Bright points and ejections observed on the sun by the KORONAS-FOTON instrument TESIS

    Science.gov (United States)

    Ulyanov, A. S.; Bogachev, S. A.; Kuzin, S. V.

    2010-10-01

    Five-second observations of the solar corona carried out in the FeIX 171 Å line by the KORONAS-FOTON instrument TESIS are used to study the dynamics of small-scale coronal structures emitting in and around coronal bright points. The small-scale structures of the lower corona display complex dynamics similar to those of magnetic loops located at higher levels of the solar corona. Numerous detected oscillating structures with sizes below 10 000 km display oscillation periods from 50 to 350 s. The period distributions of these structures are different for P 150 s, which implies that different oscillation modes are excited at different periods. The small-scale structures generate numerous flare-like events with energies 1024-1026 erg (nanoflares) and with a spatial density of one event per arcsecond or more observed over an area of 4 × 1011 km2. Nanoflares are not associated with coronal bright points, and almost uniformly cover the solar disk in the observation region. The ejections of solar material from the coronal bright points demonstrate velocities of 80-110 km/s.

  15. Research and technology, 1993. Salute to Skylab and Spacelab: Two decades of discovery

    Science.gov (United States)

    1993-01-01

    A summary description of Skylab and Spacelab is presented. The section on Advanced Studies includes projects in space science, space systems, commercial use of space, and transportation systems. Within the Research Programs area, programs are listed under earth systems science, space physics, astrophysics, and microgravity science and applications. Technology Programs include avionics, materials and manufacturing processes, mission operations, propellant and fluid management, structures and dynamics, and systems analysis and integration. Technology transfer opportunities and success are briefly described. A glossary of abbreviations and acronyms is appended as is a list of contract personnel within the program areas.

  16. Remote sensing optical instrumentation for enhanced space weather monitoring from the L1 and L5 Lagrange points

    Science.gov (United States)

    Kraft, S.; Puschmann, K. G.; Luntama, J. P.

    2017-09-01

    As part of the Space Situational Awareness Programme (SSA), ESA has initiated the assessment of two missions currently foreseen to be implemented to enable enhanced space weather monitoring. These missions utilize the positioning of satellites at the Lagrangian L1 and L5 points. These Phase 0 or Pre-Phase A mission studies are about to be completed and will thereby have soon passed the Mission Definition Review. Phase A studies are planned to start in 2017. The space weather monitoring system currently considers four remote sensing optical instruments and several in-situ instruments to analyse the Sun and the solar wind conditions, in order to provide early warnings of increased solar activity and to identify and mitigate potential threats to society and ground, airborne and space based infrastructure. The suggested optical instruments take heritage from ESA and NASA science missions like SOHO, STEREO and Solar Orbiter, but the instruments are foreseen to be optimized for operational space weather monitoring purposes with high reliability and robustness demands. The instruments are required to provide high quality measurements particularly during severe space weather events. The program intends to utilize the results of the on-going ESA instrument prototyping and technology development activities, and to initiate pre-developments of the operational space weather instruments to ensure the required maturity before the mission implementation.

  17. Measurement noise of a point autofocus surface topography instrument

    DEFF Research Database (Denmark)

    Feng, Xiaobing; Quagliotti, Danilo; Maculotti, Giacomo

    Optical instruments for areal topography measurement can be especially sensitive to noise when scanning is required. Such noise has different sources, including those internally generated and external sources from the environment.......Optical instruments for areal topography measurement can be especially sensitive to noise when scanning is required. Such noise has different sources, including those internally generated and external sources from the environment....

  18. Simple Approaches to Minimally-Instrumented, Microfluidic-Based Point-of-Care Nucleic Acid Amplification Tests

    Science.gov (United States)

    Mauk, Michael G.; Song, Jinzhao; Liu, Changchun; Bau, Haim H.

    2018-01-01

    Designs and applications of microfluidics-based devices for molecular diagnostics (Nucleic Acid Amplification Tests, NAATs) in infectious disease testing are reviewed, with emphasis on minimally instrumented, point-of-care (POC) tests for resource-limited settings. Microfluidic cartridges (‘chips’) that combine solid-phase nucleic acid extraction; isothermal enzymatic nucleic acid amplification; pre-stored, paraffin-encapsulated lyophilized reagents; and real-time or endpoint optical detection are described. These chips can be used with a companion module for separating plasma from blood through a combined sedimentation-filtration effect. Three reporter types: Fluorescence, colorimetric dyes, and bioluminescence; and a new paradigm for end-point detection based on a diffusion-reaction column are compared. Multiplexing (parallel amplification and detection of multiple targets) is demonstrated. Low-cost detection and added functionality (data analysis, control, communication) can be realized using a cellphone platform with the chip. Some related and similar-purposed approaches by others are surveyed. PMID:29495424

  19. Simple Approaches to Minimally-Instrumented, Microfluidic-Based Point-of-Care Nucleic Acid Amplification Tests

    Directory of Open Access Journals (Sweden)

    Michael G. Mauk

    2018-02-01

    Full Text Available Designs and applications of microfluidics-based devices for molecular diagnostics (Nucleic Acid Amplification Tests, NAATs in infectious disease testing are reviewed, with emphasis on minimally instrumented, point-of-care (POC tests for resource-limited settings. Microfluidic cartridges (‘chips’ that combine solid-phase nucleic acid extraction; isothermal enzymatic nucleic acid amplification; pre-stored, paraffin-encapsulated lyophilized reagents; and real-time or endpoint optical detection are described. These chips can be used with a companion module for separating plasma from blood through a combined sedimentation-filtration effect. Three reporter types: Fluorescence, colorimetric dyes, and bioluminescence; and a new paradigm for end-point detection based on a diffusion-reaction column are compared. Multiplexing (parallel amplification and detection of multiple targets is demonstrated. Low-cost detection and added functionality (data analysis, control, communication can be realized using a cellphone platform with the chip. Some related and similar-purposed approaches by others are surveyed.

  20. Hematological measurements in rats flown on Spacelab shuttle SL-3

    International Nuclear Information System (INIS)

    Lange, R.D.; Andrews, R.B.; Gibson, L.A.; Congdon, C.C.; Wright, P.; Dunn, C.D.R.; Jones, J.B.

    1987-01-01

    Previous studies have shown that a decrease in red cell mass occurs in astronauts, and some studies indicate a leukocytosis occurs. A life science module housing young and mature rats was flown on shuttle mission Spacelab 3 (SL-3), and the results of hematology studies of flight and control rats are presented. Statistically significant increases in the hematocrit, red blood cell counts, and hemoglobin determinations, together with a mild neutrophilia and lymphopenia, were found in flight animals. No significant changes were found in bone marrow and spleen cell differentials or erythropoietin determinations. Clonal assays demonstrated an increased erythroid colony formation of flight animal bone marrow cells at erythropoietin doses of 0.02 and 1.0 U/ml but not 0.20 U/ml. These results agree with some but vary from other previously published studies. Erythropoietin assays performed by radioimmunoassay and clonal studies were performed for the first time

  1. Scientific management and implementation of the geophysical fluid flow cell for Spacelab missions

    Science.gov (United States)

    Hart, J.; Toomre, J.

    1980-01-01

    Scientific support for the spherical convection experiment to be flown on Spacelab 3 was developed. This experiment takes advantage of the zero gravity environment of the orbiting space laboratory to conduct fundamental fluid flow studies concerned with thermally driven motions inside a rotating spherical shell with radial gravity. Such a system is a laboratory analog of large scale atmospheric and solar circulations. The radial body force necessary to model gravity correctly is obtained by using dielectric polarization forces in a radially varying electric field to produce radial accelerations proportional to temperature. This experiment will answer fundamental questions concerned with establishing the preferred modes of large scale motion in planetary and stellar atmospheres.

  2. The Development of a Survey Instrument on South Dakota's School District Leadership Climate as Related to Deming's Fourteen Points.

    Science.gov (United States)

    Holmes, Lawrence W. O.; And Others

    Development of an instrument to measure baseline levels of applied Total Quality Management (TQM) practices in South Dakota before the introduction and dissemination of TQM theory to the state's educational leaders is described. Using the interpretation of Deming's 14 points that was developed by J. J. Bonstigl, a 115-item initial item pool was…

  3. Phase B: Final definition and preliminary design study for the initial Atmospheric Cloud Physics Laboratory (ACPL): A spacelab mission payload. Final review (DR-MA-03)

    Science.gov (United States)

    Clausen, O. W.

    1976-01-01

    Systems design for an initial atmospheric cloud physics laboratory to study microphysical processes in zero gravity is presented. Included are descriptions of the fluid, thermal, mechanical, control and data, and electrical distribution interfaces with Spacelab. Schedule and cost analysis are discussed.

  4. Instrument air dew point requirements -- 108-P, L, K

    International Nuclear Information System (INIS)

    Fairchild, P.N.

    1994-01-01

    The 108 Building dew point analyzers measure dew point at atmospheric pressure. Existing 108 Roundsheets state the maximum dew point temperature shall be less than -50 F. After repeatedly failing to maintain a -50 F dew point temperature Reactor Engineering researched the basis for the existing limit. This report documents the results of the study and provides technical justification for a new maximum dew point temperature of -35 F at atmospheric pressure as read by the 108 building dew point analyzers

  5. Man in space - A time for perspective. [crew performance on Space Shuttle-Spacelab program

    Science.gov (United States)

    Winter, D. L.

    1975-01-01

    Factors affecting crew performances in long-term space flights are examined with emphasis on the Space Shuttle-Spacelab program. Biomedical investigations carried out during four Skylab missions indicate that initially rapid changes in certain physiological parameters, notably in cardiovascular response and red-blood-cell levels, lead to an adapted condition. Calcium loss remains a potential problem. Space Shuttle environmental control and life-support systems are described together with technology facilitating performance of mission objectives in a weightless environment. It is concluded that crew requirements are within the physical and psychological capability of astronauts, but the extent to which nonastronaut personnel will be able to participate without extensive training and pre-conditioning remains to be determined.

  6. A Decade of Life Sciences Experiment Unique Equipment Development for Spacelab and Space Station, 1990-1999

    Science.gov (United States)

    Savage, Paul D.; Connolly, J. P.; Navarro, B. J.

    1999-01-01

    Ames Research Center's Life Sciences Division has developed and flown an extensive array of spaceflight experiment unique equipment (EUE) during the last decade of the twentieth century. Over this ten year span, the EUE developed at ARC supported a vital gravitational biology flight research program executed on several different platforms, including the Space Shuttle, Spacelab, and Space Station Mir. This paper highlights some of the key EUE elements developed at ARC and flown during the period 1990-1999. Resulting lessons learned will be presented that can be applied to the development of similar equipment for the International Space Station.

  7. A critical review of the life sciences project management at Ames Research Center for the Spacelab Mission development test 3

    Science.gov (United States)

    Helmreich, R. L.; Wilhelm, J. M.; Tanner, T. A.; Sieber, J. E.; Burgenbauch, S. F.

    1979-01-01

    A management study was initiated by ARC (Ames Research Center) to specify Spacelab Mission Development Test 3 activities and problems. This report documents the problems encountered and provides conclusions and recommendations to project management for current and future ARC life sciences projects. An executive summary of the conclusions and recommendations is provided. The report also addresses broader issues relevant to the conduct of future scientific missions under the constraints imposed by the space environment.

  8. Smart Cup: A Minimally-Instrumented, Smartphone-Based Point-of-Care Molecular Diagnostic Device.

    Science.gov (United States)

    Liao, Shih-Chuan; Peng, Jing; Mauk, Michael G; Awasthi, Sita; Song, Jinzhao; Friedman, Harvey; Bau, Haim H; Liu, Changchun

    2016-06-28

    Nucleic acid amplification-based diagnostics offer rapid, sensitive, and specific means for detecting and monitoring the progression of infectious diseases. However, this method typically requires extensive sample preparation, expensive instruments, and trained personnel. All of which hinder its use in resource-limited settings, where many infectious diseases are endemic. Here, we report on a simple, inexpensive, minimally-instrumented, smart cup platform for rapid, quantitative molecular diagnostics of pathogens at the point of care. Our smart cup takes advantage of water-triggered, exothermic chemical reaction to supply heat for the nucleic acid-based, isothermal amplification. The amplification temperature is regulated with a phase-change material (PCM). The PCM maintains the amplification reactor at a constant temperature, typically, 60-65°C, when ambient temperatures range from 12 to 35°C. To eliminate the need for an optical detector and minimize cost, we use the smartphone's flashlight to excite the fluorescent dye and the phone camera to record real-time fluorescence emission during the amplification process. The smartphone can concurrently monitor multiple amplification reactors and analyze the recorded data. Our smart cup's utility was demonstrated by amplifying and quantifying herpes simplex virus type 2 (HSV-2) with LAMP assay in our custom-made microfluidic diagnostic chip. We have consistently detected as few as 100 copies of HSV-2 viral DNA per sample. Our system does not require any lab facilities and is suitable for use at home, in the field, and in the clinic, as well as in resource-poor settings, where access to sophisticated laboratories is impractical, unaffordable, or nonexistent.

  9. Critical review of Ames Life Science participation in Spacelab Mission Development Test 3: The SMD 3 management study

    Science.gov (United States)

    Helmreich, R.; Wilhelm, J.; Tanner, T. A.; Sieber, J. E.; Burgenbauch, S.

    1978-01-01

    A management study was conducted to specify activities and problems encountered during the development of procedures for documentation and crew training on experiments, as well as during the design, integration, and delivery of a life sciences experiment payload to Johnson Space Center for a 7 day simulation of a Spacelab mission. Conclusions and recommendations to project management for current and future Ames' life sciences projects are included. Broader issues relevant to the conduct of future scientific missions under the constraints imposed by the environment of space are also addressed.

  10. Magnetic suspension and pointing system. [on a carrier vehicle

    Science.gov (United States)

    Anderson, W. W.; Groom, N. J. (Inventor)

    1979-01-01

    Apparatus for providing accurate pointing of instruments on a carrier vehicle and for providing isolation of the instruments from the vehicle's motion disturbances is presented. The apparatus includes two assemblies, with connecting interfaces, each assembly having a separate function. The first assembly is attached to the carrier vehicle and consists of an azimuth gimbal and an elevation gimbal which provide coarse pointing of the instruments by allowing two rotations of the instruments relative to the carrier vehicle. The second or vernier pointing assembly is made up of magnetic suspension and fine pointing actuators, roll motor segments, and an instrument mounting plate around which a continuous annular rim is attached which provides appropriate magnetic circuits for the actuators and the roll motor segments. The vernier pointing assembly provides six degree-of-freedom isolation from carrier motion disturbances.

  11. Research on lettuce growth technology onboard Chinese Tiangong II Spacelab

    Science.gov (United States)

    Shen, Yunze; Guo, Shuangsheng; Zhao, Pisheng; Wang, Longji; Wang, Xiaoxia; Li, Jian; Bian, Qiang

    2018-03-01

    Lettuce was grown in a space vegetable cultivation facility onboard the Tiangong Ⅱ Spacelab during October 18 to November 15, 2016, in order to testify the key cultivating technology in CELSS under spaceflight microgravity condition. Potable water was used for irrigation of rooting substrate and the SRF (slowly released fertilizer) offered mineral nutrition for plant growth. Water content and electric conductivity in rooting substrate were measured based on FDR(frequency domain reflectometry) principle applied first in spaceflight. Lettuce germinated with comparative growth vigor as the ground control, showing that the plants appeared to be not stressed by the spaceflight environment. Under microgravity, lettuce grew taller and showed deeper green color than the ground control. In addition, the phototropism of the on-orbit plants was more remarkable. The nearly 30-d spaceflight test verified the seed fixation technology and water& nutrition management technology, which manifests the feasibility of FDR being used for measuring moisture content and electric conductivity in rooting zone under microgravity. Furthermore, the edibility of the space-grown vegetable was proved, providing theoretical support for astronaut to consume the space vegetable in future manned spaceflight.

  12. Advances in Miniaturized Instruments for Genomics

    Directory of Open Access Journals (Sweden)

    Cihun-Siyong Alex Gong

    2014-01-01

    Full Text Available In recent years, a lot of demonstrations of the miniaturized instruments were reported for genomic applications. They provided the advantages of miniaturization, automation, sensitivity, and specificity for the development of point-of-care diagnostics. The aim of this paper is to report on recent developments on miniaturized instruments for genomic applications. Based on the mature development of microfabrication, microfluidic systems have been demonstrated for various genomic detections. Since one of the objectives of miniaturized instruments is for the development of point-of-care device, impedimetric detection is found to be a promising technique for this purpose. An in-depth discussion of the impedimetric circuits and systems will be included to provide total consideration of the miniaturized instruments and their potential application towards real-time portable imaging in the “-omics” era. The current excellent demonstrations suggest a solid foundation for the development of practical and widespread point-of-care genomic diagnostic devices.

  13. Calibrate the aerial surveying instrument by the limited surface source and the single point source that replace the unlimited surface source

    CERN Document Server

    Lu Cun Heng

    1999-01-01

    It is described that the calculating formula and surveying result is found on the basis of the stacking principle of gamma ray and the feature of hexagonal surface source when the limited surface source replaces the unlimited surface source to calibrate the aerial survey instrument on the ground, and that it is found in the light of the exchanged principle of the gamma ray when the single point source replaces the unlimited surface source to calibrate aerial surveying instrument in the air. Meanwhile through the theoretical analysis, the receiving rate of the crystal bottom and side surfaces is calculated when aerial surveying instrument receives gamma ray. The mathematical expression of the gamma ray decaying following height according to the Jinge function regularity is got. According to this regularity, the absorbing coefficient that air absorbs the gamma ray and the detective efficiency coefficient of the crystal is calculated based on the ground and air measuring value of the bottom surface receiving cou...

  14. Man/terminal interaction evaluation of computer operating system command and control service concepts. [in Spacelab

    Science.gov (United States)

    Dodson, D. W.; Shields, N. L., Jr.

    1978-01-01

    The Experiment Computer Operating System (ECOS) of the Spacelab will allow the onboard Payload Specialist to command experiment devices and display information relative to the performance of experiments. Three candidate ECOS command and control service concepts were reviewed and laboratory data on operator performance was taken for each concept. The command and control service concepts evaluated included a dedicated operator's menu display from which all command inputs were issued, a dedicated command key concept with which command inputs could be issued from any display, and a multi-display concept in which command inputs were issued from several dedicated function displays. Advantages and disadvantages are discussed in terms of training, operational errors, task performance time, and subjective comments of system operators.

  15. Importance of temperature control for HEFLEX, a biological experiment for Spacelab 1. [plant gravitational physiology study

    Science.gov (United States)

    Chapman, D. K.; Brown, A. H.

    1979-01-01

    The importance of temperature control to HEFLEX, a Spacelab experiment designed to measure kinetic properties of Helianthis nutation in a low-g environment, is discussed. It is argued that the development of the HEFLEX experiment has been severely hampered by the inadequate control of ambient air temperature provided by the spacecraft module design. A worst case calculation shows that delivery of only 69% of the maximum yield of useful data from the HEFLEX system is guaranteed; significant data losses from inadequate temperature control are expected. The magnitude of the expected data losses indicates that the cost reductions associated with imprecise temperature controls may prove to be a false economy in the long term.

  16. Changes in pituitary growth hormone cells prepared from rats flown on Spacelab 3

    Science.gov (United States)

    Grindeland, R.; Hymer, W. C.; Farrington, M.; Fast, T.; Hayes, C.; Motter, K.; Patil, L.; Vasques, M.

    1987-01-01

    The effect of exposure to microgravity on pituitary gland was investigated by examining cells isolated from anterior pituitaries of rats flown on the 7-day Spacelab 3 mission and, subsequently, cultured for 6 days. Compared with ground controls, flight cells contained more intracellular growth hormone (GH); however, the flight cells released less GH over the 6-day culture period and after implantation into hypophysectomized rats than did the control cells. Compared with control rats, glands from large rats (400 g) contained more somatotrophs (44 percent compared with 37 percent in control rats); small rats (200 g) showed no difference. No major differences were found in the somatotroph ultrastructure (by TEM) or in the pattern of the immunoactive GH variants. However, high-performance liquid chromatography fractionation of culture media indicated that flight cells released much less of a biologically active high-molecular weight GH variant, suggesting that space flight may lead to secretory dysfunction.

  17. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  18. Instrument for track linear element recognition

    International Nuclear Information System (INIS)

    Krupnov, V.E.; Fedotov, O.P.

    1977-01-01

    Described is the construction of instrument for recognizing linear elements of tracks. For designing this instrument use has been made of the algorithm for conversion of the point data into a set of linear elements. The flowsheet of the instrument shows its major units such as data converter, data representation register unit, local computers, interface with the central computer. The data representation register unit comprises sixteen registers and is capable of presenting data from sixteen lines when raster scanning of a picture taken from a track chamber. The maximum capacity of the code of the coordinate of a point recorded on a picture is up to 16 digits. The time of the inner operating cycle of the instrument is 1.3 μs. The average time required for processing data containing sixteen scanning lines is 250 μs

  19. Salivary gland ultrastructure and cyclic AMP-dependent reactions in Spacelab 3 rats

    International Nuclear Information System (INIS)

    Mednieks, M.I.; Hand, A.R.

    1987-01-01

    Environmental stimuli influencing catecholamine levels induce changes in cyclic AMP-dependent reactions and cell morphology in the rat parotid. Responses of salivary glands to spaceflight were determined by measurement of cyclic AMP-mediated reactions in fresh-frozen salivary glands and by microscopic evaluation of ultrastructure in fixed parotid glands. Decreased cell-free protein phosphorylation, determined by autoradiography, occurred in parotid glands in three of five flight animals. Protein kinase activity ratios were decreased in the soluble and increased in the particulate fractions of Spacelab 3 (SL-3) rat sublingual glands, compared with ground controls. Biochemical analyses show that effects of space flight on salivary glands are similar to those induced experimentally by physiological manipulation or alteration of catecholamine levels. Morphological evaluation of three SL-3 rat parotid glands showed increased numbers of lysosomes, autophagic vacuoles containing degenerating secretory product, and accumulation of lipid droplets. Since these animals lost weight, consistent with disruption of food and water consumption, morphological changes may in part be due to decreased masticatory stimulation, as occurs with reduced food intake or a liquid diet. The observed changes may reflect physiological responses of the gastrointestinal and autonomic systems to effects of spaceflight

  20. Analysis of point source size on measurement accuracy of lateral point-spread function of confocal Raman microscopy

    Science.gov (United States)

    Fu, Shihang; Zhang, Li; Hu, Yao; Ding, Xiang

    2018-01-01

    Confocal Raman Microscopy (CRM) has matured to become one of the most powerful instruments in analytical science because of its molecular sensitivity and high spatial resolution. Compared with conventional Raman Microscopy, CRM can perform three dimensions mapping of tiny samples and has the advantage of high spatial resolution thanking to the unique pinhole. With the wide application of the instrument, there is a growing requirement for the evaluation of the imaging performance of the system. Point-spread function (PSF) is an important approach to the evaluation of imaging capability of an optical instrument. Among a variety of measurement methods of PSF, the point source method has been widely used because it is easy to operate and the measurement results are approximate to the true PSF. In the point source method, the point source size has a significant impact on the final measurement accuracy. In this paper, the influence of the point source sizes on the measurement accuracy of PSF is analyzed and verified experimentally. A theoretical model of the lateral PSF for CRM is established and the effect of point source size on full-width at half maximum of lateral PSF is simulated. For long-term preservation and measurement convenience, PSF measurement phantom using polydimethylsiloxane resin, doped with different sizes of polystyrene microspheres is designed. The PSF of CRM with different sizes of microspheres are measured and the results are compared with the simulation results. The results provide a guide for measuring the PSF of the CRM.

  1. Calibrate the aerial surveying instrument by the limited surface source and the single point source that replace the unlimited surface source

    International Nuclear Information System (INIS)

    Lu Cunheng

    1999-01-01

    It is described that the calculating formula and surveying result is found on the basis of the stacking principle of gamma ray and the feature of hexagonal surface source when the limited surface source replaces the unlimited surface source to calibrate the aerial survey instrument on the ground, and that it is found in the light of the exchanged principle of the gamma ray when the single point source replaces the unlimited surface source to calibrate aerial surveying instrument in the air. Meanwhile through the theoretical analysis, the receiving rate of the crystal bottom and side surfaces is calculated when aerial surveying instrument receives gamma ray. The mathematical expression of the gamma ray decaying following height according to the Jinge function regularity is got. According to this regularity, the absorbing coefficient that air absorbs the gamma ray and the detective efficiency coefficient of the crystal is calculated based on the ground and air measuring value of the bottom surface receiving count rate (derived from total receiving count rate of the bottom and side surface). Finally, according to the measuring value, it is proved that imitating the change of total receiving gamma ray exposure rate of the bottom and side surfaces with this regularity in a certain high area is feasible

  2. Conceptual Design of an In-Space Cryogenic Fluid Management Facility

    Science.gov (United States)

    Willen, G. S.; Riemer, D. H.; Hustvedt, D. C.

    1981-01-01

    The conceptual design of a Spacelab experiment to develop the technology associated with low gravity propellant management is presented. The proposed facility consisting of a supply tank, receiver tank, pressurization system, instrumentation, and supporting hardware, is described. The experimental objectives, the receiver tank to be modeled, and constraints imposed on the design by the space shuttle, Spacelab, and scaling requirements, are described. The conceptual design, including the general configurations, flow schematics, insulation systems, instrumentation requirements, and internal tank configurations for the supply tank and the receiver tank, is described. Thermal, structural, fluid, and safety and reliability aspects of the facility are analyzed. The facility development plan, including schedule and cost estimates for the facility, is presented. A program work breakdown structure and master program schedule for a seven year program are included.

  3. A statistical approach to instrument calibration

    Science.gov (United States)

    Robert R. Ziemer; David Strauss

    1978-01-01

    Summary - It has been found that two instruments will yield different numerical values when used to measure identical points. A statistical approach is presented that can be used to approximate the error associated with the calibration of instruments. Included are standard statistical tests that can be used to determine if a number of successive calibrations of the...

  4. Gaseous environment of the Shuttle early in the Spacelab 2 mission

    Science.gov (United States)

    Pickett, Jolene S.; Murphy, Gerald B.; Kurth, William S.

    1988-01-01

    A cold-cathode ionization gage was flown on Space Shuttle flight STS-5IF as part of the Spacelab 2 payload. Neutral pressure data that were taken in the payload bay during the first few hours on orbit are presented. These data show that when the payload bay is oriented such that the atmospheric gases are ramming into it, the pressure rises to a peak of 4 x 10 to the -6th Torr. Pressure is also slightly higher during the sunlit portion of each orbit. Outgassing of the payload bay causes the pressure to be elevated to a few times 10 to the -6th Torr early in the mission. In addition, several effects on pressure have been identified that are due to chemical releases. Substantial increases (50-150 percent) are seen during another experiment's gas purge. Orbiter chemical-release effects include: pressure increases of 200 percent up to 7 x 10 to the -6th Torr due to Orbital Maneuvering System burns, minor perturbations in pressure due to vernier thruster firings and little or no increase in pressure due to water dumps. In the case of vernier thruster firings, effects are seen only from down-firing thrusters in the back of the Orbiter, which are probably due to reflection of thruster gases off Orbiter surfaces.

  5. Economic instruments for environmental policy making in Ontario

    International Nuclear Information System (INIS)

    Barg, S.; Duraiappah, A.; Van Exan, S.

    2000-01-01

    The conditions and approaches required for a successful implementation of economic instruments in Ontario are reviewed. The advantages and disadvantages of economic instruments are discussed, as are some design issues. Some best practices and practical experiences from Canada, the United States, and Europe are examined through the use of nine specific case studies. Each one highlights a different environmental challenge, such as energy efficiency, air pollution, water pollution, waste management along with the solutions that were implemented. The situations described were not all successful, but there is much to be learned from unsuccessful episodes. Lessons learned from the review of the case studies were presented. The points to ponder when using economic instruments in Ontario were highlighted. The command and control policy instrument must be kept in context when considering economic instruments. The reasons that underline the preference of the economic theory for economic instruments are discussed. The different types of economic instruments are described, and the considerations related to the design and comparison of economic instruments is briefly discussed. The authors concluded with several points to ponder: there are a number of options available, details must not be neglected, consultation with the interested parties is important, there is a need for frequent reassessment, and using a number of instruments is helpful. 55 refs., tabs., figs

  6. Acid dew point measurement in flue gases

    Energy Technology Data Exchange (ETDEWEB)

    Struschka, M.; Baumbach, G.

    1986-06-01

    The operation of modern boiler plants requires the continuous measurement of the acid dew point in flue gases. An existing measuring instrument was modified in such a way that it can determine acid dew points reliably, reproduceably and continuously. The authors present the mechanisms of the dew point formation, the dew point measuring principle, the modification and the operational results.

  7. Surveillance of instruments by noise analysis

    International Nuclear Information System (INIS)

    Thie, J.A.

    1981-01-01

    Random fluctuations of neutron flux, temperature, and pressure in a reactor provide multifrequency excitation of the corresponding instrumentation chains. Mathematical descriptors suitable for characterizing the output, or noise, of the instrumentation are reviewed with a view toward using such noise in detecting instrument faults. Demonstrations of the feasibility of this approach in a number of reactors provide illustrative examples. Comparisons with traditional surveillance testing are made, and a number of advantages and some disadvantages of using noise analysis as a supplementary technique are pointed out

  8. Technical evaluation of the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Point Beach Nuclear Power Plant, Units 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Laudenbach, D.H.

    1979-03-01

    The technical evaluation is presented for the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Point Beach nuclear power plant, Units 1 and 2. Design basis criteria used to evaluate the acceptability of the system included operator action, system testability, single failure criterion, and seismic Category I and IEEE Std-279-1971 criteria. This report is supplied as part of the Selected Electrical, Instrumentation, and Control Systems Issues Support Program being conducted for the U.S. Nuclear Regulatory Commission by Lawrence Livermore Laboratory.

  9. Technical evaluation of the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Point Beach Nuclear Power Plant, Units 1 and 2

    International Nuclear Information System (INIS)

    Laudenbach, D.H.

    1979-03-01

    The technical evaluation is presented for the electrical, instrumentation, and control design aspects of the low temperature overpressure protection system for the Point Beach nuclear power plant, Units 1 and 2. Design basis criteria used to evaluate the acceptability of the system included operator action, system testability, single failure criterion, and seismic Category I and IEEE Std-279-1971 criteria. This report is supplied as part of the Selected Electrical, Instrumentation, and Control Systems Issues Support Program being conducted for the U.S. Nuclear Regulatory Commission by Lawrence Livermore Laboratory

  10. Monitoring Of The Middle Atmosphere: Grille Spectrometer Experiment Results On Board SPACELAB 1 And Scientific Program Of ATLAS 1 Mission

    Science.gov (United States)

    Papineau, N.; Camy-Peyret, C.; Ackerman, Marcel E.

    1989-10-01

    Measurements of atmospheric trace gases have been performed during the first Spacelab mission on board the Space Shuttle. The principle of the observations is infrared absorption spectroscopy using the solar occultation technique. Infrared absorption spectra of NO, CO, CO2, NO2, N20, CH4 and H2O have been recorded using the Grille spectrometer developped by ONERA and IASB. From the observed spectra, vertical profiles for these molecules have been derived. The present paper summarizes the main results and compares them with computed vertical profiles from a zonally averaged model of the middle atmosphere. The scientific objectives of the second mission, Atlas 1, planned for 1990 are also presented.

  11. Ergonomic investigation of weight distribution of laparoscopic instruments.

    Science.gov (United States)

    Lin, Chiuhsiang Joe; Chen, Hung-Jen; Lo, Ying-Chu

    2011-06-01

    Laparoscopic surgery procedures require highly specialized visually controlled movements. Investigations of industrial applications indicate that the length as well as the weight of hand-held tools substantially affects movement time (MT). Different weight distributions may have similar effects on long-shafted laparoscopic instruments when performing surgical procedures. For this reason, the current experiment aimed at finding direct evidence of the weight distribution effect in an accurate task. Ten right-handed subjects made continuous Fitts' pointing tasks using a long laparoscopic instrument. The factors and levels were target width: (2.5, 3, 3.5, and 4 cm), target distance (14, 23, and 37 cm), and weight distribution (uniform, front, middle, and rear). Weight distribution was made by chips of lead attached to the laparoscopic instrument. MT, error rate, and throughput (TP) were recorded as dependent variables. There were significant differences between the weight distribution in MT and in TP. The middle position was found to require the least time to manipulate the laparoscopic instrument in pointing tasks and also obtained the highest TP. These analyses and findings pointed to a design direction for the ergonomics and usability of the long hand-held tool such as the laparoscopic instrument in this study. To optimize efficiency in using these tools, the consideration of a better weight design is important and should not be neglected.

  12. Methane Flux Estimation from Point Sources using GOSAT Target Observation: Detection Limit and Improvements with Next Generation Instruments

    Science.gov (United States)

    Kuze, A.; Suto, H.; Kataoka, F.; Shiomi, K.; Kondo, Y.; Crisp, D.; Butz, A.

    2017-12-01

    Atmospheric methane (CH4) has an important role in global radiative forcing of climate but its emission estimates have larger uncertainties than carbon dioxide (CO2). The area of anthropogenic emission sources is usually much smaller than 100 km2. The Thermal And Near infrared Sensor for carbon Observation Fourier-Transform Spectrometer (TANSO-FTS) onboard the Greenhouse gases Observing SATellite (GOSAT) has measured CO2 and CH4 column density using sun light reflected from the earth's surface. It has an agile pointing system and its footprint can cover 87-km2 with a single detector. By specifying pointing angles and observation time for every orbit, TANSO-FTS can target various CH4 point sources together with reference points every 3 day over years. We selected a reference point that represents CH4 background density before or after targeting a point source. By combining satellite-measured enhancement of the CH4 column density and surface measured wind data or estimates from the Weather Research and Forecasting (WRF) model, we estimated CH4emission amounts. Here, we picked up two sites in the US West Coast, where clear sky frequency is high and a series of data are available. The natural gas leak at Aliso Canyon showed a large enhancement and its decrease with time since the initial blowout. We present time series of flux estimation assuming the source is single point without influx. The observation of the cattle feedlot in Chino, California has weather station within the TANSO-FTS footprint. The wind speed is monitored continuously and the wind direction is stable at the time of GOSAT overpass. The large TANSO-FTS footprint and strong wind decreases enhancement below noise level. Weak wind shows enhancements in CH4, but the velocity data have large uncertainties. We show the detection limit of single samples and how to reduce uncertainty using time series of satellite data. We will propose that the next generation instruments for accurate anthropogenic CO2 and CH

  13. Objective evaluation of analyzer performance based on a retrospective meta-analysis of instrument validation studies: point-of-care hematology analyzers.

    Science.gov (United States)

    Cook, Andrea M; Moritz, Andreas; Freeman, Kathleen P; Bauer, Natali

    2017-06-01

    Information on quality requirements and objective evaluation of performance of veterinary point-of-care analyzers (POCAs) is scarce. The study was aimed at assessing observed total errors (TE obs s) for veterinary hematology POCAs via meta-analysis and comparing TE obs to allowable total error (TE a ) specifications based on experts' opinions. The TE obs for POCAs (impedance and laser-based) was calculated based on data from instrument validation studies published between 2006 and 2013 as follows: TE obs = 2 × CV [%] + bias [%]. The CV was taken from published studies; the bias was estimated from the regression equation at 2 different concentration levels of measurands. To fulfill quality requirements, TE obs should be 60% of analyzers showed TE obs hematology variables, respectively. For the CBC, TE obs was TE a (data from 3 analyzers). This meta-analysis is considered a pilot study. Experts' requirements (TE obs < TE a ) were fulfilled for most measurands except HGB (due to instrument-related bias for the ADVIA 2120) and platelet counts. Available data on the WBC differential count suggest an analytic bias, so nonstatistical quality control is recommended. © 2017 American Society for Veterinary Clinical Pathology.

  14. Vertical profiles of ozone, carbon monoxide, and dew-point temperature obtained during GTE/CITE 1, October-November 1983. [Chemical Instrumentation Test and Evaluation

    Science.gov (United States)

    Fishman, Jack; Gregory, Gerald L.; Sachse, Glen W.; Beck, Sherwin M.; Hill, Gerald F.

    1987-01-01

    A set of 14 pairs of vertical profiles of ozone and carbon monoxide, obtained with fast-response instrumentation, is presented. Most of these profiles, which were measured in the remote troposphere, also have supporting fast-response dew-point temperature profiles. The data suggest that the continental boundary layer is a source of tropospheric ozone, even in October and November, when photochemical activity should be rather small. In general, the small-scale vertical variability between CO and O3 is in phase. At low latitudes this relationship defines levels in the atmosphere where midlatitude air is being transported to lower latitudes, since lower dew-point temperatures accompany these higher CO and O3 concentrations. A set of profiles which is suggestive of interhemispheric transport is also presented. Independent meteorological analyses support these interpretations.

  15. Use of a FORTH-based PROLOG for real-time expert systems. 1: Spacelab life sciences experiment application

    Science.gov (United States)

    Paloski, William H.; Odette, Louis L.; Krever, Alfred J.; West, Allison K.

    1987-01-01

    A real-time expert system is being developed to serve as the astronaut interface for a series of Spacelab vestibular experiments. This expert system is written in a version of Prolog that is itself written in Forth. The Prolog contains a predicate that can be used to execute Forth definitions; thus, the Forth becomes an embedded real-time operating system within the Prolog programming environment. The expert system consists of a data base containing detailed operational instructions for each experiment, a rule base containing Prolog clauses used to determine the next step in an experiment sequence, and a procedure base containing Prolog goals formed from real-time routines coded in Forth. In this paper, we demonstrate and describe the techniques and considerations used to develop this real-time expert system, and we conclude that Forth-based Prolog provides a viable implementation vehicle for this and similar applications.

  16. Temperature documentation - instrument for quality assurance; Temperaturdokumentation - Instrument der Qualitaetssicherung

    Energy Technology Data Exchange (ETDEWEB)

    Hegglin, A [Wurm AG, Winterthur (Switzerland)

    2000-10-01

    Important inspection points of a HACCP concept are the temperatures. On the basis of the demands for a systematic temperature documentation, the application of control systems and instruments is described by several examples. (orig.) [German] Wichtige Kontrollpunkte eines HACCP-Konzepts sind die Temperaturen. Ausgehend von den Anforderungen, die an eine systematische Temperaturedokumentation gestellt werden, wird der Einsatz geeigneter Regel- und Ueberwachungsgeraete an mehreren Beispielen erlaeutert. (orig.)

  17. Spacelab 1 hematology experiment (INS103): Influence of space flight on erythrokinetics in man

    Science.gov (United States)

    Leach, C. S.; Chen, J. P.; Crosby, W.; Dunn, C. D. R.; Johnson, P. C.; Lange, R. D.; Larkin, E.; Tavassoli, M.

    1985-01-01

    An experiment conducted on the 10-day Spacelab 1 mission aboard the ninth Space Shuttle flight in November to December 1983 was designed to measure factors involved in the control of erythrocyte turnover that might be altered during weightlessness. Blood samples were collected before, during, and after the flight. Immediately after landing, red cell mass showed a mean decrease of 9.3 percent in the four astronauts. Neither hyperoxia nor an increase in blood phosphate was a cause of the decrease. Red cell survival time and iron incorporation postflight were not significantly different from their preflight levels. Serum haptoglobin did not decrease, indicating that intravascular hemolysis was not a major cause of red cell mass change. An increase in serum ferritin after the second day of flight may have been caused by red cell breakdown early in flight. Erythropoietin levels decreased during and after flight, but preflight levels were high and the decrease was not significant. The space flight-induced decrease in red cell mass may result from a failure of erythropoiesis to replace cells destroyed by the spleen soon after weightlessness is attained.

  18. Communication network for decentralized remote tele-science during the Spacelab mission IML-2

    Science.gov (United States)

    Christ, Uwe; Schulz, Klaus-Juergen; Incollingo, Marco

    1994-01-01

    The ESA communication network for decentralized remote telescience during the Spacelab mission IML-2, called Interconnection Ground Subnetwork (IGS), provided data, voice conferencing, video distribution/conferencing and high rate data services to 5 remote user centers in Europe. The combination of services allowed the experimenters to interact with their experiments as they would normally do from the Payload Operations Control Center (POCC) at MSFC. In addition, to enhance their science results, they were able to make use of reference facilities and computing resources in their home laboratory, which typically are not available in the POCC. Characteristics of the IML-2 communications implementation were the adaptation to the different user needs based on modular service capabilities of IGS and the cost optimization for the connectivity. This was achieved by using a combination of traditional leased lines, satellite based VSAT connectivity and N-ISDN according to the simulation and mission schedule for each remote site. The central management system of IGS allows minimization of staffing and the involvement of communications personnel at the remote sites. The successful operation of IGS for IML-2 as a precursor network for the Columbus Orbital Facility (COF) has proven the concept for communications to support the operation of the COF decentralized scenario.

  19. Marketing instruments of foreign trade promotion

    Directory of Open Access Journals (Sweden)

    Bjelić Predrag

    2011-01-01

    Full Text Available Instruments of promotion as a part of marketing mix are usually associated with companies but more and more countries use this instrument in order to boost their exports. These foreign trade promotion instruments are now popular in many countries in the world since their use is not opposed to any World Trade Organization rules. Marketing instruments of trade promotions are the most important. They include National Exhibitions and National labels of origin and quality. In order to coordinate the application of these instruments countries have established national bodies for trade promotion. Many studies in the past had argued that national Agencies established to promote export did not had any real success, but recent studies indicate that they could have a significant impact on country export promotion. The result of this rise in impact of national export promotion agencies is due to international effort spearheaded by International Trade Center. The aim of this paper is to point out types and methods of marketing instruments application in trade promotion and to present the effectiveness of these instruments applications.

  20. Incore instrument device

    International Nuclear Information System (INIS)

    Sakima, Naoki

    1996-01-01

    An incore instrument device has an integrally disposed touch panel having a function of displaying an operation indication method such as for setting of conditions for incore measurement and information processing and results of the incore measurement and a function capable of conducting operation indication such as for setting conditions and information processing for incore measurement relative to a control section upon touching an information position on a displayed information. In addition, an information processing section comprising a man-machine function program formed so as to recognize the content of the operation indication for the incore measurement by touching and let the control section to conduct it is disposed to the outside by way of a communication interface. In addition, a programming device is disposed for forming and rewriting the program of the man-machine function relative to the information processing section. Then, when various indication operations are conducted upon performing incore measurement, a view point can be concentrated to one predetermined point thereby enabling to improve the operationability without danger. In addition, the programming of the man-machine function does not apply unnecessary load to the control section in the incore instrumentation device. (N.H.)

  1. Ambulatory heart rate is underestimated when measured by an Ambulatory Blood Pressure device

    NARCIS (Netherlands)

    Vrijkotte, T.G.M.; de Geus, E.J.C.

    1999-01-01

    Objective: To test the validity of ambulatory heart rate (HR) assessment with a cuff ambulatory blood pressure (ABP) monitor. Design: Cross-instrument comparison of HR measured intermittently by a cuff ABP monitor (SpaceLabs, Redmond, Washington, USA), with HR derived from continuous

  2. Ambulatory heart rate is underestimated when measured by an ambulatory blood pressure device

    NARCIS (Netherlands)

    Vrijkotte, T. G.; de Geus, E. J.

    2001-01-01

    To test the validity of ambulatory heart rate (HR) assessment with a cuff ambulatory blood pressure (ABP) monitor. Cross-instrument comparison of HR measured intermittently by a cuff ABP monitor (SpaceLabs, Redmond, Washington, USA), with HR derived from continuous electrocardiogram (ECG) recordings

  3. Ambulatory heart rate is underestimated when measured by an ambulatory blood pressure device

    NARCIS (Netherlands)

    Vrijkotte, T.G.M.; de Geus, E.J.C.

    2001-01-01

    Objective: To test the validity of ambulatory heart rate (HR) assessment with a cuff ambulatory blood pressure (ABP) monitor. Design: Cross-instrument comparison of HR measured intermittently by a cuff ABP monitor (SpaceLabs, Redmond, Washington, USA), with HR derived from continuous

  4. a Circleless "2D/3D Total STATION": a Low Cost Instrument for Surveying, Recording Point Clouds, Documentation, Image Acquisition and Visualisation

    Science.gov (United States)

    Scherer, M.

    2013-07-01

    Hardware and software of the universally applicable instrument - referred to as a 2D/3D total station - are described here, as well as its practical use. At its core it consists of a 3D camera - often also called a ToF camera, a pmd camera or a RIM-camera - combined with a common industrial 2D camera. The cameras are rigidly coupled with their optical axes in parallel. A new type of instrument was created mounting this 2D/3D system on a tripod in a specific way. Because of it sharing certain characteristics with a total station and a tacheometer, respectively, the new device was called a 2D/3D total station. It may effectively replace a common total station or a laser scanner in some respects. After a brief overview of the prototype's features this paper then focuses on the methodological characteristics for practical application. Its usability as a universally applicable stand-alone instrument is demonstrated for surveying, recording RGB-coloured point clouds as well as delivering images for documentation and visualisation. Because of its limited range (10m without reflector and 150 m to reflector prisms) and low range accuracy (ca. 2 cm to 3 cm) compared to present-day total stations and laser scanners, the practical usage of the 2D/3D total station is currently limited to acquisition of accidents, forensic purpuses, speleology or facility management, as well as architectural recordings with low requirements regarding accuracy. However, the author is convinced that in the near future advancements in 3D camera technology will allow this type of comparatively low cost instrument to replace the total station as well as the laser scanner in an increasing number of areas.

  5. Life sciences payload definition and integration study. Volume 2: Requirements, design, and planning studies for the carry-on laboratories. [for Spacelab

    Science.gov (United States)

    1974-01-01

    The task phase concerned with the requirements, design, and planning studies for the carry-on laboratory (COL) began with a definition of biomedical research areas and candidate research equipment, and then went on to develop conceptual layouts for COL which were each evaluated in order to arrive at a final conceptual design. Each step in this design/evaluation process concerned itself with man/systems integration research and hardware, and life support and protective systems research and equipment selection. COL integration studies were also conducted and include attention to electrical power and data management requirements, operational considerations, and shuttle/Spacelab interface specifications. A COL program schedule was compiled, and a cost analysis was finalized which takes into account work breakdown, annual funding, and cost reduction guidelines.

  6. Technological considerations in emergency instrument preparedness

    International Nuclear Information System (INIS)

    Selby, J.M.

    1976-01-01

    Emergency preparedness has been emphasized during the development of the nuclear industry. Existing instrumentation technology has been effectively applied to minimizing the probability of accidents. Radiological instrumentation provided for the measurement of ambient radiation levels or routine releases of radioactive material is usually adequate to provide an early warning that an accident is occurring. In contrast, radiological instrumentation capable of providing a reasonable measure of the source term which could be involved in a severe accident has not received enough attention. In emergency planning the capability should be established for identifying as promptly as possible the need for evasive action out in the plant environs and for minimizing the consequences of an accident in terms of resultant human exposure. Therefore instrumentation is required to measure the source term no matter where the point of release might be, together with instrumentation for obtaining meteorological data sufficient to establish the path of the release in the environment

  7. Preventive maintenance instrumentation results in Spanish nuclear power plants

    International Nuclear Information System (INIS)

    Curiel, M.; Palomo, M. J.; Verdu, G.; Arnaldos, A.

    2010-10-01

    This paper is a recompilation of the most significance results in relation to the researching in preventive and predictive maintenance in critical nuclear instrumentation for power plant operation, which it is being developed by Logistica y Acondicionamientos Industriales and the Isirym Institute of the Polytechnic University of Valencia. Instrumentation verification and test, it is a priority of the power plants control and instrumentation department's technicians. These procedures are necessary information for the daily power plant work. It is performed according to different procedures and in different moments of the fuel cycle depending on the instrumentation critical state and the monitoring process. Normally, this study is developed taking into account the instantaneous values of the instrumentation measures and, after their conversion to physical magnitude, they are analyzed according to the power plant operation point. Moreover, redundant sensors measurements are taken into consideration to the equipment and/or power plant monitoring. This work goes forward and it is in advanced to the instrument analysis as it is, independently of the operation point, using specific signal analysis techniques for preventive and predictive maintenance, with the object to obtain not only information about possible malfunctions, but the degradation scale presented in the instrument or in the system measured. We present seven real case studies of Spanish nuclear power plants each of them shall give a significant contribution to problem resolution and power plant performance. (Author)

  8. Surface-sensitive conductivity measurement using a micro multi-point probe approach

    DEFF Research Database (Denmark)

    Perkins, Edward; Barreto, Lucas; Wells, Justin

    2013-01-01

    An instrument for microscale electrical transport measurements in ultra-high vacuum is presented. The setup is constructed around collinear lithographically-created multi-point probes with a contact spacing down to 500 nm. Most commonly, twelve-point probes are used. These probes are approached...... measurements with an equidistant four-point probe for a wide range of contact spacings. In this way, it is possible to distinguish between bulk-like and surface-like conduction. The paper describes the design of the instrument and the approach to data and error analysis. Application examples are given...

  9. Cross-instrument Analysis Correlation Software

    Energy Technology Data Exchange (ETDEWEB)

    2017-06-28

    This program has been designed to assist with the tracking of a sample from one analytical instrument to another such as SEM, microscopes, micro x-ray diffraction and other instruments where particular positions/locations on the sample are examined, photographed, etc. The software is designed to easily enter the position of fiducials and locations of interest such that in a future session in the same of different instrument the positions of interest can be re-found through using the known location fiducials in the current and reference session to transform the point into the current sessions coordinate system. The software is dialog box driven guiding the user through the necessary data entry and program choices. Information is stored in a series of text based extensible markup language (XML) files.

  10. Pointing gesture in a bird- merely instrumental or a cognitively complex behavior?

    Directory of Open Access Journals (Sweden)

    Gisela KAPLAN

    2011-08-01

    Full Text Available Gestures, particularly pointing, are regarded as important pre-speech acts. Intentional and referential pointing has been shown previously in humans and apes but not in songbirds, although some avian species show cognitive abilities rivaling those of apes, and their brain structures and functions show putative preconditions for referential gestural signaling (i.e. mirror neurons, links of vocal learning nuclei to discrete brain areas active during limb and body movements. The results reported are based on trials testing predator detection and responses to a taxidermic model of a wedge-tailed eagle by Australian magpies Gymnorhina tibicen. Magpies were subjected to three conditions of finding this model in their territory (open, sheltered and hidden. In the sheltered and hidden conditions, the discoverer simultaneously engaged in alarm calls and beak pointing, a behavior that has not been described previously. Other group members at once assembled and, after watching the first bird, adopted the same posture by pointing to the location of the intruder. The question is whether beak and body movements orienting towards important stimuli or events are instances of arousal, imitation or intentional communication. The latter presupposes that onlookers interpret the signal and respond by altering their own behavior appropriate to the original stimulus and not merely by imitating the first signaler. Evidence presented here indicates that the act of pointing may well be a complex cognitive behavior, i.e., an intentional and referential signal, showing that pointing is not limited to having hands and arms [Current Zoology 57 (4: 453–467, 2011].

  11. Instruments for the promotion of environmental innovations. Stocktaking, evaluation and deficit analysis; Instrumente zur Foerderung von Umweltinnovationen. Bestandsaufnahme, Bewertung und Defizitanalyse

    Energy Technology Data Exchange (ETDEWEB)

    Rennings, Klaus; Rammer, Christian; Oberndorfer, Ulrich [Zentrum fuer Europaeische Wirtschaftsforschung (ZEW), GmbH, Mannheim (DE)] (and others)

    2008-03-15

    In the ecological report 2006 of the Federal Ministry for the Environment, Nature Conservation and Nuclear Safety (Berlin, Federal Republic of Germany) with the title ''Environment - Innovation - Occupation'', the Federal Ministry outlines the concept of an innovative oriented environmental policy. An innovative environmental policy contributes to the reduction of the environmental pollution and the ecological damages of industrial production. In this background, the question arises, how the environmental policy can support appropriate innovative activities. For this, the research project under consideration presents the following contributions: (a) Overview of the most important instruments for the promotion of environmental innovations in Germany; (b) Estimation of the effectiveness of the instruments including gap analysis and deficit analysis; (c) Presentation of foreign Best Practice Examples (instruments and environmental political beginnings); (d) Proposals for priority environmental political starting points to the advancement of the equipment and pointing out the further research need.

  12. MANU. Instrumentation of Buffer Demo. Preliminary Study

    International Nuclear Information System (INIS)

    Laaksonen, R.

    2010-01-01

    The purpose of this work is to describe feasible measuring and monitoring alternatives which can be used, if needed, in medium to full scale nuclear waste repository deposition hole mock-up tests. The focus of the work was to determine what variables can actually be measured, how to achieve the measurements and what kind of demands comes from the modelling, scientific, and technical points of view. This project includes a review of the previous waste repository mock-up tests carried out in several European countries such as Belgium, Czech Republic, Spain and Sweden. Also information was gathered by interviewing domestic and foreign scientists specialized in the fields of measurement instrumentation and related in-situ and laboratory work. On the basis of this review, recommendations were developed for the necessary actions needed to be done from the instrumentation point of view for future tests. It is possible to measure and monitor the processes going on in a deposition hole in-situ conditions. The data received during a test in real repository conditions enables to follow the processes and to verify the hypothesis made on the behaviour of various components of the repository: buffer, canister, rock and backfill. Because full scale testing is expensive, the objectives and hypothesis must be carefully set and the test itself with its instrumentation must serve very specific objectives. The main purpose of mock-up tests is to verify that the conditions surrounding the canister are according to the design requirements. A whole mock-up test and demonstration process requires a lot of time and effort. The instrumentation part of the work must also start at early stages to ensure that the instrumentation itself will not become bottlenecked nor suffer from low quality solutions. The planning of the instrumentation work could be done in collaboration with foreign scientists which have participated to previous instrumentation projects. (orig.)

  13. Imaging instrument for positron emitting heavy ion beam injection

    International Nuclear Information System (INIS)

    Llacer, J.; Chatterjee, A.; Jackson, H.C.; Lin, J.C.; Zunzunegui, M.V.

    1978-10-01

    The design and performance of an instrument for the imaging of coincidence annihilation gamma rays emitted from the end point of the trajectories of radioactive high-energy heavy ions is described. The positron-emitting heavy ions are the result of nuclear fragmentation of accelerated heavy ions used in cancer therapy or diagnostic medicine. The instrument constructed is capable of locating the ion beam trajectory end point within 1 mm for an injected activity of 200 nanoCi in a measurement time of 1 sec in some favorable conditions. Limited imaging in three dimensions is also demonstrated

  14. Reactor instrumentation and control

    International Nuclear Information System (INIS)

    Wach, D.; Beraha, D.

    1980-01-01

    The methods for measuring radiation are shortly reviewed. The instrumentation for neutron flux measurement is classified into out-of-core and in-core instrumentation. The out-of-core instrumentation monitors the operational range from the subcritical reactor to full power. This large range is covered by several measurement channels which derive their signals from counter tubes and ionization chambers. The in-core instrumentation provides more detailed information on the power distribution in the core. The self-powered neutron detectors and the aeroball system in PWR reactors are discussed. Temperature and pressure measurement devices are briefly discussed. The different methods for leak detection are described. In concluding the plant instrumentation part some new monitoring systems and analysis methods are presented: early failure detection methods by noise analysis, acoustic monitoring and vibration monitoring. The presentation of the control starts from an qualitative assessment of the reactor dynamics. The chosen control strategy leads to the definition of the part-load diagram, which provides the set-points for the different control systems. The tasks and the functions of these control systems are described. In additiion to the control, a number of limiting systems is employed to keep the reactor in a safe operating region. Finally, an outlook is given on future developments in control, concerning mainly the increased application of process computers. (orig./RW)

  15. Preventive maintenance instrumentation results in Spanish nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Curiel, M. [Logistica y Acondicionamientos Industriales SAU, Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Palomo, M. J.; Verdu, G. [ISIRYM, Universidad Politecnica de Valencia, Camino de Vera s/n, Valencia (Spain); Arnaldos, A., E-mail: m.curiel@lainsa.co [TITANIA Servicios Tecnologicos SL, Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain)

    2010-10-15

    This paper is a recompilation of the most significance results in relation to the researching in preventive and predictive maintenance in critical nuclear instrumentation for power plant operation, which it is being developed by Logistica y Acondicionamientos Industriales and the Isirym Institute of the Polytechnic University of Valencia. Instrumentation verification and test, it is a priority of the power plants control and instrumentation department's technicians. These procedures are necessary information for the daily power plant work. It is performed according to different procedures and in different moments of the fuel cycle depending on the instrumentation critical state and the monitoring process. Normally, this study is developed taking into account the instantaneous values of the instrumentation measures and, after their conversion to physical magnitude, they are analyzed according to the power plant operation point. Moreover, redundant sensors measurements are taken into consideration to the equipment and/or power plant monitoring. This work goes forward and it is in advanced to the instrument analysis as it is, independently of the operation point, using specific signal analysis techniques for preventive and predictive maintenance, with the object to obtain not only information about possible malfunctions, but the degradation scale presented in the instrument or in the system measured. We present seven real case studies of Spanish nuclear power plants each of them shall give a significant contribution to problem resolution and power plant performance. (Author)

  16. Point-of-care instrument for monitoring tissue health during skin graft repair

    Science.gov (United States)

    Gurjar, R. S.; Seetamraju, M.; Zhang, J.; Feinberg, S. E.; Wolf, D. E.

    2011-06-01

    We have developed the necessary theoretical framework and the basic instrumental design parameters to enable mapping of subsurface blood dynamics and tissue oxygenation for patients undergoing skin graft procedures. This analysis forms the basis for developing a simple patch geometry, which can be used to map by diffuse optical techniques blood flow velocity and tissue oxygenation as a function of depth in subsurface tissue.skin graft, diffuse correlation analysis, oxygen saturation.

  17. Visual tracking of da Vinci instruments for laparoscopic surgery

    Science.gov (United States)

    Speidel, S.; Kuhn, E.; Bodenstedt, S.; Röhl, S.; Kenngott, H.; Müller-Stich, B.; Dillmann, R.

    2014-03-01

    Intraoperative tracking of laparoscopic instruments is a prerequisite to realize further assistance functions. Since endoscopic images are always available, this sensor input can be used to localize the instruments without special devices or robot kinematics. In this paper, we present an image-based markerless 3D tracking of different da Vinci instruments in near real-time without an explicit model. The method is based on different visual cues to segment the instrument tip, calculates a tip point and uses a multiple object particle filter for tracking. The accuracy and robustness is evaluated with in vivo data.

  18. Development of method for experimental determination of wheel–rail contact forces and contact point position by using instrumented wheelset

    International Nuclear Information System (INIS)

    Bižić, Milan B; Petrović, Dragan Z; Tomić, Miloš C; Djinović, Zoran V

    2017-01-01

    This paper presents the development of a unique method for experimental determination of wheel–rail contact forces and contact point position by using the instrumented wheelset (IWS). Solutions of key problems in the development of IWS are proposed, such as the determination of optimal locations, layout, number and way of connecting strain gauges as well as the development of an inverse identification algorithm (IIA). The base for the solution of these problems is the wheel model and results of FEM calculations, while IIA is based on the method of blind source separation using independent component analysis. In the first phase, the developed method was tested on a wheel model and a high accuracy was obtained (deviations of parameters obtained with IIA and really applied parameters in the model are less than 2%). In the second phase, experimental tests on the real object or IWS were carried out. The signal-to-noise ratio was identified as the main influential parameter on the measurement accuracy. Тhе obtained results have shown that the developed method enables measurement of vertical and lateral wheel–rail contact forces Q and Y and their ratio Y / Q with estimated errors of less than 10%, while the estimated measurement error of contact point position is less than 15%. At flange contact and higher values of ratio Y / Q or Y force, the measurement errors are reduced, which is extremely important for the reliability and quality of experimental tests of safety against derailment of railway vehicles according to the standards UIC 518 and EN 14363. The obtained results have shown that the proposed method can be successfully applied in solving the problem of high accuracy measurement of wheel–rail contact forces and contact point position using IWS. (paper)

  19. Investigation of potential factors affecting the measurement of dew point temperature in oil-soaked transformers

    Science.gov (United States)

    Kraus, Adam H.

    Moisture within a transformer's insulation system has been proven to degrade its dielectric strength. When installing a transformer in situ, one method used to calculate the moisture content of the transformer insulation is to measure the dew point temperature of the internal gas volume of the transformer tank. There are two instruments commercially available that are designed for dew point temperature measurement: the Alnor Model 7000 Dewpointer and the Vaisala DRYCAPRTM Hand-Held Dewpoint Meter DM70. Although these instruments perform an identical task, the design technology behind each instrument is vastly different. When the Alnor Dewpointer and Vaisala DM70 instruments are used to measure the dew point of the internal gas volume simultaneously from a pressurized transformer, their differences in dew point measurement have been observed to vary as much as 30 °F. There is minimal scientific research available that focuses on the process of measuring dew point of a gas inside a pressurized transformer, let alone this observed phenomenon. The primary objective of this work was to determine what effect certain factors potentially have on dew point measurements of a transformer's internal gas volume, in hopes of understanding the root cause of this phenomenon. Three factors that were studied include (1) human error, (2) the use of calibrated and out-of-calibration instruments, and (3) the presence of oil vapor gases in the dry air sample, and their subsequent effects on the Q-value of the sampled gas. After completing this portion of testing, none of the selected variables proved to be a direct cause of the observed discrepancies between the two instruments. The secondary objective was to validate the accuracy of each instrument as compared to its respective published range by testing against a known dew point temperature produced by a humidity generator. In a select operating range of -22 °F to -4 °F, both instruments were found to be accurate and within their

  20. Payload/orbiter contamination control requirement study: Preliminary contamination mission support plan. [a management analysis of project planning of spacecraft sterilization

    Science.gov (United States)

    Bareiss, L. E.; Hooper, V. W.; Ress, E. B.

    1976-01-01

    Progress is reported on the mission support plan and those support activities envisioned to be applicable and necessary during premission and postmission phases of the Spacelab program. The purpose, role, and requirements of the contamination control operations for the first two missions of the Spacelab equipped Space Transportation System are discussed. The organization of the contamination control operation and its relationship to and interfaces with other mission support functions is also discussed. Some specific areas of contamination to be investigated are treated. They are: (1) windows and viewports, (2) experiment equipment, (3) thermal control surfaces, (4) the contaminant induced atmosphere (as differentiated from the normal ambient atmosphere at the orbit altitude), and (5) optical navigation instruments.

  1. Prospects for the applications of computer in the field of domestic nuclear medicinal instrument

    International Nuclear Information System (INIS)

    Zhao Changhe

    1993-01-01

    The current situation and prospects about domestic nuclear medical instrument, as well as the comparisons of computer application in nuclear medical instruments with in other medical instruments from various points of view have all been described in the paper

  2. Instruments shaping sustainable mobility of urban residents

    Directory of Open Access Journals (Sweden)

    Krzysztof Grzelec

    2016-10-01

    Full Text Available Urban development increases the demand for efficient, fast, safe ecological transport. Extensive development of urban transport system, in particular transport infrastructure, changed the point of view about transport needs. Research on the effectiveness of transport systems for years accompanied the study of mobility. The development of modern technology, the need to increase efficiency of transport and increase environmental awareness determined the development of principles and instruments of sustainable mobility. This paper discusses these instruments, their characteristics and application examples.

  3. Transgressive or Instrumental?

    DEFF Research Database (Denmark)

    Chemi, Tatiana

    2018-01-01

    Contemporary practices that connect the arts with learning are widespread at all level of educational systems and in organisations, but they include very diverse approaches, multiple methods and background values. Regardless of explicit learning benefits, the arts/learning partnerships bring about...... creativity and the other on practices of arts-integration. My final point rests on the belief that the opposition of transgression and instrumentality is a deceiving perspective on the arts, against the background of the aesthetic plurality and hybridity....

  4. A levitation instrument for containerless study of molten materials.

    Science.gov (United States)

    Nordine, Paul C; Merkley, Dennis; Sickel, Jeffrey; Finkelman, Steve; Telle, Rainer; Kaiser, Arno; Prieler, Robert

    2012-12-01

    A new aero-acoustic levitation instrument (AAL) has been installed at the Institute for Mineral Engineering at RWTH University in Aachen, Germany. The AAL employs acoustically stabilized gas jet levitation with laser-beam heating and melting to create a contact-free containerless environment for high temperature materials research. Contamination-free study of liquids is possible at temperatures in excess of 3000 °C and of undercooled liquids at temperatures far below the melting point. Digital control technology advances the art of containerless experiments to obtain long-term levitation stability, allowing new experiments in extreme temperature materials research and to study operation of the levitation instrument itself. Experiments with liquid Al(2)O(3) at temperatures more than 3200 °C, 1200 °C above the melting point, and with liquid Y(3)Al(5)O(12) far below the melting point are reported. Fast pyrometry and video recording instruments yield crystallization rates in undercooled liquid Al(2)O(3) as a function of temperature. Levitation of dense liquid HfO(2) at temperatures above 2900 °C is demonstrated. Capabilities are described for resonant frequency matching in the three-axis acoustic positioning system, acoustic control of sample spin, and position control of standing wave nodes to stabilize levitation under changing experimental conditions. Further development and application of the levitation technology is discussed based on the results of experiments and modeling of instrument operations.

  5. Nuclear instrument maintenance - problems, solutions, and obstacles

    International Nuclear Information System (INIS)

    Vuister, P.H.

    1983-01-01

    In 200 laboratories of South-East Asia, Latin America and Africa a survey was made of the state of instrumentation for nuclear medicine. The principal cause of failures and defects was inadequate quality control and preventive maintenance. On the basis of the survey coordinated research programs were compiled for the maintenance of nuclear instruments. The four principal points of the programs are: to safeguard quality and stable electric power supplies for the instruments, to safeguard permanent temperature and humidity in the environment in which the equipment is operated, effective maintenance, and training of personnel. In the years 1981 and 1982, 14 local training courses were run in which emphasis was put on practicals and tests in mechanics and electronics

  6. Instrumentation Cables Test Plan

    Energy Technology Data Exchange (ETDEWEB)

    Muna, Alice Baca [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); LaFleur, Chris Bensdotter [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-10-01

    and fluctuate, while the thermoplastic insulated cables, the instrument reading fell off-scale rapidly. From an operational point of view, the latter failure characteristics would likely be identified as a failure from the effects of fire, while the former may result in inaccurate readings.

  7. A new instrument for statistical process control of thermoset molding

    International Nuclear Information System (INIS)

    Day, D.R.; Lee, H.L.; Shepard, D.D.; Sheppard, N.F.

    1991-01-01

    The recent development of a rugged ceramic mold mounted dielectric sensor and high speed dielectric instrumentation now enables monitoring and statistical process control of production molding over thousands of runs. In this work special instrumentation and software (ICAM-1000) was utilized that automatically extracts critical point during the molding process including flow point, viscosity minimum gel inflection, and reaction endpoint. In addition, other sensors were incorporated to measure temperature and pressure. The critical point as well as temperature and pressure were then recorded during normal production and then plotted in the form of statistical process control (SPC) charts. Experiments have been carried out in RIM, SMC, and RTM type molding operations. The influence of temperature, pressure chemistry, and other variables has been investigated. In this paper examples of both RIM and SMC are discussed

  8. Modal survey testing of the Lidar In-space Technology Experiment (LITE) - A Space Shuttle payload

    Science.gov (United States)

    Anderson, J. B.; Coleman, A. D.; Driskill, T. C.; Lindell, M. C.

    This paper presents the results of the modal survey test of the Lidar In-space Technology Experiment (LITE), a Space Shuttle payload mounted in a Spacelab flight single pallet. The test was performed by the Dynamics Test Branch at Marshall Space Flight Center, AL and run in two phases. In the first phase, an unloaded orthogrid connected to the pallet with 52 tension struts was tested. This test included 73 measurement points in three directions. In the second phase, the pallet was integrated with mass simulators mounted on the flight support structure to represent the dynamics (weight and center of gravity) of the various components comprising the LITE experiment and instrumented at 213 points in 3 directions. The test article was suspended by an air bag system to simulate a free-free boundary condition. This paper presents the results obtained from the testing and analytical model correlation efforts. The effect of the suspension system on the test article is also discussed.

  9. CMOS Electrochemical Instrumentation for Biosensor Microsystems: A Review

    Directory of Open Access Journals (Sweden)

    Haitao Li

    2016-12-01

    Full Text Available Modern biosensors play a critical role in healthcare and have a quickly growing commercial market. Compared to traditional optical-based sensing, electrochemical biosensors are attractive due to superior performance in response time, cost, complexity and potential for miniaturization. To address the shortcomings of traditional benchtop electrochemical instruments, in recent years, many complementary metal oxide semiconductor (CMOS instrumentation circuits have been reported for electrochemical biosensors. This paper provides a review and analysis of CMOS electrochemical instrumentation circuits. First, important concepts in electrochemical sensing are presented from an instrumentation point of view. Then, electrochemical instrumentation circuits are organized into functional classes, and reported CMOS circuits are reviewed and analyzed to illuminate design options and performance tradeoffs. Finally, recent trends and challenges toward on-CMOS sensor integration that could enable highly miniaturized electrochemical biosensor microsystems are discussed. The information in the paper can guide next generation electrochemical sensor design.

  10. Scientific instruments, scientific progress and the cyclotron

    International Nuclear Information System (INIS)

    Baird, David; Faust, Thomas

    1990-01-01

    Philosophers speak of science in terms of theory and experiment, yet when they speak of the progress of scientific knowledge they speak in terms of theory alone. In this article it is claimed that scientific knowledge consists of, among other things, scientific instruments and instrumental techniques and not simply of some kind of justified beliefs. It is argued that one aspect of scientific progress can be characterized relatively straightforwardly - the accumulation of new scientific instruments. The development of the cyclotron is taken to illustrate this point. Eight different activities which promoted the successful completion of the cyclotron are recognised. The importance is in the machine rather than the experiments which could be run on it and the focus is on how the cyclotron came into being, not how it was subsequently used. The completed instrument is seen as a useful unit of scientific progress in its own right. (UK)

  11. Preventive maintenance instrumentation results in Spanish nuclear power plants

    International Nuclear Information System (INIS)

    Palomo Anaya, M. Jose; Verdu Martin, Gumersindo; Arnaldos Gonzalvez, Adoracion; Nieva, Marcelino Curiel

    2011-01-01

    This paper is a recompilation of the most significant results in relation to the researching in Preventive and Predictive Maintenance in critical nuclear instrumentation for power plant operation, which it is being developed by Logistica y Acondicionamientos Industriales and The Isirym Institute of the Polytechnic University of Valencia. Instrumentation verification and test, it is a priority of the Power Plants Control and Instrumentation Department technicians. These procedures are necessary information for the daily power plant work. It is performed according to different procedures and in different moments of the fuel cycle depending on the instrumentation critical state and the monitoring process. Normally, this study is developed taking into account the instantaneous values of the instrumentation measures and, after their conversion to physical magnitude, they are analyzed according to the power plant operation point. Moreover, redundant sensors measurements are taken into consideration to the equipment and/or power plant monitoring. This work goes forward and it is in advanced to the instrument analysis as it is, independently of the operation point, using specific signal analysis techniques for preventive and predictive maintenance, with the aim to obtain not only information about possible malfunctions, but the degradation scale presented in the instrument or in the system measured. We present seven real case studies of Spanish Nuclear Power Plants each of them shall give a significant contribution to problem resolution and power plant performance: Fluctuations in sensor lines (case 1), Air presence in feed water lines (case 2), Root valve partially closed (case 3), Sensor malfunctions (case 4), Electrical source malfunctions (case 5), RTD malfunctions (case 6) and LPRM malfunctions (case 7). (author)

  12. Preventive maintenance instrumentation results in Spanish nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Palomo Anaya, M. Jose; Verdu Martin, Gumersindo, E-mail: mpalomo@iqn.upv.es, E-mail: gverdu@iqn.upv.es [ISIRYM Universidad Politecnica de Valencia, Valencia (Spain); Arnaldos Gonzalvez, Adoracion, E-mail: a.arnaldos@titaniast.com [TITANIA Servicios Tecnologicos SL, Valencia (Spain); Nieva, Marcelino Curiel, E-mail: m.curiel@lainsa.com [Logistica y Acondicionamientos Industriales SAU (LAINSA), Valencia (Spain)

    2011-07-01

    This paper is a recompilation of the most significant results in relation to the researching in Preventive and Predictive Maintenance in critical nuclear instrumentation for power plant operation, which it is being developed by Logistica y Acondicionamientos Industriales and The Isirym Institute of the Polytechnic University of Valencia. Instrumentation verification and test, it is a priority of the Power Plants Control and Instrumentation Department technicians. These procedures are necessary information for the daily power plant work. It is performed according to different procedures and in different moments of the fuel cycle depending on the instrumentation critical state and the monitoring process. Normally, this study is developed taking into account the instantaneous values of the instrumentation measures and, after their conversion to physical magnitude, they are analyzed according to the power plant operation point. Moreover, redundant sensors measurements are taken into consideration to the equipment and/or power plant monitoring. This work goes forward and it is in advanced to the instrument analysis as it is, independently of the operation point, using specific signal analysis techniques for preventive and predictive maintenance, with the aim to obtain not only information about possible malfunctions, but the degradation scale presented in the instrument or in the system measured. We present seven real case studies of Spanish Nuclear Power Plants each of them shall give a significant contribution to problem resolution and power plant performance: Fluctuations in sensor lines (case 1), Air presence in feed water lines (case 2), Root valve partially closed (case 3), Sensor malfunctions (case 4), Electrical source malfunctions (case 5), RTD malfunctions (case 6) and LPRM malfunctions (case 7). (author)

  13. "Atmospheric Radiation Measurement (ARM) Research Facility at Oliktok Point Alaska"

    Science.gov (United States)

    Helsel, F.; Ivey, M.; Hardesty, J.; Roesler, E. L.; Dexheimer, D.

    2017-12-01

    Scientific Infrastructure To Support Atmospheric Science, Aerosol Science and UAS's for The Department Of Energy's Atmospheric Radiation Measurement Programs At The Mobile Facility 3 Located At Oliktok Point, Alaska.The Atmospheric Radiation Measurement (ARM) Program's Mobile Facility 3 (AMF3) located at Oliktok Point, Alaska is a U.S. Department of Energy (DOE) site designed to collect data and help determine the impact that clouds and aerosols have on solar radiation. AMF3 provides a scientific infrastructure to support instruments and collect arctic data for the international arctic research community. The infrastructure at AMF3/Oliktok is designed to be mobile and it may be relocated in the future to support other ARM science missions. AMF3's present base line instruments include: scanning precipitation Radars, cloud Radar, Raman Lidar, Eddy correlation flux systems, Ceilometer, Balloon sounding system, Atmospheric Emitted Radiance Interferometer (AERI), Micro-pulse Lidar (MPL) Along with all the standard metrological measurements. In addition AMF3 provides aerosol measurements with a Mobile Aerosol Observing System (MAOS). Ground support for Unmanned Aerial Systems (UAS) and tethered balloon flights. Data from these instruments and systems are placed in the ARM data archives and are available to the international research community. This poster will discuss what instruments and systems are at the ARM Research Facility at Oliktok Point Alaska.

  14. Characterization of MIPAS elevation pointing

    Directory of Open Access Journals (Sweden)

    M. Kiefer

    2007-01-01

    Full Text Available Sufficient knowledge of the pointing is essential for analyses of limb emission measurements. The scientific retrieval processor for MIPAS on ENVISAT operated at IMK allows the retrieval of pointing information in terms of tangent altitudes along with temperature. The retrieved tangent altitudes are independent of systematic offsets in the engineering Line-Of-Sight (LOS information delivered with the ESA Level 1b product. The difference of pointing retrieved from the reprocessed high resolution MIPAS spectra and the engineering pointing information was examined with respect to spatial/temporal behaviour. Among others the following characteristics of MIPAS pointing could be identified: Generally the engineering tangent altitudes are too high by 0–1.8 km with conspicuous variations in this range over time. Prior to December of 2003 there was a drift of about 50–100 m/h, which was due to a slow change in the satellite attitude. A correction of this attitude is done twice a day, which leads to discontinuities in the order of 1–1.5 km in the tangent altitudes. Occasionally discontinuities up to 2.5 km are found, as already reported from MIPAS and SCIAMACHY observations. After an update of the orbit position software in December 2003 values of drift and jumps are much reduced. There is a systematic difference in the mispointing between the poles which amounts to 1.5–2 km, i.e. there is a conspicuous orbit-periodic feature. The analysis of the correlation between the instrument's viewing angle azimuth and differential mispointing supports the hypotheses that a major part of this latter phenomenon can be attributed to an error in the roll angle of the satellite/instrument system of approximately 42 mdeg. One conclusion is that ESA level 2 data should be compared to other data exclusively on tangent pressure levels. Complementary to IMK data, ESA operational LOS calibration results were used to characterize MIPAS pointing. For this purpose

  15. Development of an analytical instrumentation for determining U, Np and Pu

    International Nuclear Information System (INIS)

    Wu Jizong; Guo Kuisheng; Liu Huanliang

    1995-01-01

    An analytical instrumentation for determining U, Np and Pu in the solution of reprocessing factory are made. The principle of the instrumentation is based on that of flow injection analysis and ion chromatography. The instrumentation is composed of controlling box and working box, the distance between the two boxes is 1.5 m. Important quantity of impurity is permitted. The determination limit is 1 mg/l. The relative standard deviation is better than 5%. The instrumentation can be used in 1AF, 1AP and other many controlling points for determining U, Np and Pu

  16. Spatial interpolation of point velocities in stream cross-section

    Directory of Open Access Journals (Sweden)

    Hasníková Eliška

    2015-03-01

    Full Text Available The most frequently used instrument for measuring velocity distribution in the cross-section of small rivers is the propeller-type current meter. Output of measuring using this instrument is point data of a tiny bulk. Spatial interpolation of measured data should produce a dense velocity profile, which is not available from the measuring itself. This paper describes the preparation of interpolation models.

  17. Statistical evaluation of recorded knowledge in nuclear and other instrumental analytical techniques

    International Nuclear Information System (INIS)

    Braun, T.

    1987-01-01

    The main points addressed in this study are the following: Statistical distribution patterns of published literature on instrumental analytical techniques 1981-1984; structure of scientific literature and heuristics for identifying active specialities and emerging hot spot research areas in instrumental analytical techniques; growth and growth rates of the literature in some of the identified hot research areas; quality and quantity in instrumental analytical research output. (orig.)

  18. ExoMars Trace Gas Orbiter Instrument Modelling Approach to Streamline Science Operations

    Science.gov (United States)

    Munoz Fernandez, Michela; Frew, David; Ashman, Michael; Cardesin Moinelo, Alejandro; Garcia Beteta, Juan Jose; Geiger, Bernhard; Metcalfe, Leo; Nespoli, Federico; Muniz Solaz, Carlos

    2018-05-01

    ExoMars Trace Gas Orbiter (TGO) science operations activities are centralised at ESAC's Science Operations Centre (SOC). The SOC receives the inputs from the principal investigators (PIs) in order to implement and deliver the spacecraft pointing requests and instrument timelines to the Mission Operations Centre (MOC). The high number of orbits per planning cycle has made it necessary to abstract the planning interactions between the SOC and the PI teams at the observation level. This paper describes the modelling approach we have conducted for TGOís instruments to streamline science operations. We have created dynamic observation types that scale to adapt to the conditions specified by the PI teams including observation timing, and pointing block parameters calculated from observation geometry. This approach is considered and improvement with respect to previous missions where the generation of the observation pointing and commanding requests was performed manually by the instrument teams. Automation software assists us to effectively handle the high density of planned orbits with increasing volume of scientific data and to successfully meet opportunistic scientific goals and objectives. Our planning tool combines the instrument observation definition files provided by the PIs together with the flight dynamics products to generate the Pointing Requests and the instrument timeline (ITL). The ITL contains all the validated commands at the TC sequence level and computes the resource envelopes (data rate, power, data volume) within the constraints. At the SOC, our main goal is to maximise the science output while minimising the number of iterations among the teams, ensuring that the timeline does not violate the state transitions allowed in the Mission Operations Rules and Constraints Document.

  19. Wear promoted in the apical third of simulated canals after instrumentation with protaper universal system

    Directory of Open Access Journals (Sweden)

    Kathrein Tapia da Silva

    2009-10-01

    Full Text Available OBJECTIVE: This study evaluated the wear in the apical third of simulate canals after preparation with ProTaper Universal Rotary System. MATERIAL AND METHODS: 24 sets of instruments were used in 24 simulated canals in transparent epoxy resin blocks with degree of curvature of either 20°or 40°. The canals were photographed preoperatively and after preparation of the apical stop with ProTaper F3, F4 and F5 instruments. The initial and final images were exported to Adobe Photoshop® software and superimposed to detect the root canal wall differences (in mm between them, in two points located 1 (A and 5 (B mm from the point where the working length was established. Data were subjected to analysis of variance to verify the existence of interaction among the factors: canal curvature, instrument size and curve location. Significant level was set at 5%. RESULTS: Regardless of the location and the canal curvature, F4 and F5 instruments produced the greatest wear (p<0.05. CONCLUSIONS: There was a deviation from the original pathway towards the outside of the root curvature in both analyzed points. All instruments produced canal transportation, but the F4 and F5 instruments produced more than the other instruments, and should thus be used with care in curved canals.

  20. Overview: Field instrumentation - A Mikado's dream

    International Nuclear Information System (INIS)

    Spittler, T.M.

    1992-01-01

    The Mikado of Gilbert ampersand Sullivan fame held out as an open-quotes object all sublimeclose quotes which he hoped to open-quotes achieve in timeclose quotes the fitting of the punishment to the crime. Like that potentate, I too have long held the hope of finding instrumentation which is ideally suited to measurement of environmental contaminants in the field. Today, at least one of us has had that dream fulfilled. For years, those of us interested in field analysis have had to apply time consuming and cumbersome methods to relatively simple and often short-term environmental measurement problems. Meanwhile, we watched the literature and perused the product blurbs in hopes of finding the ideal tools for on-site, real time analysis. Of course, that search will always go forward as better instruments are developed. Today we can finally point to many pieces of equipment that are on the market and which provide high quality data in real time for a number of the most important environmental contaminants. Furthermore, the sensitivity of some of these field instruments exceeds that of conventional lab instrumentation. Coupled with innovative techniques for sample preparation and proper quality control, field instrumentation can often go a long way to solving problems in rapid detection, quantitation, and positive identification

  1. Beam instrumentation in the LEP Pre-injector

    International Nuclear Information System (INIS)

    Battisti, S.; Bottollier, J.F.; Frammery, B.; Szeless, B.; Van Rooy, M.

    1987-01-01

    The main purpose of this paper is to review the beam instrumentation of the LEP pre-injector (LPI) including its design philosophy and software. The usefulness of these equipments for the LPI start-up is considered from an operational point of view and encountered problems are mentioned

  2. On-line testing of calibration of process instrumentation channels in nuclear power plants. Phase 2, Final report

    International Nuclear Information System (INIS)

    Hashemian, H.M.

    1995-11-01

    The nuclear industry is interested in automating the calibration of process instrumentation channels; this report provides key results of one of the sponsored projects to determine the validity of automated calibrations. Conclusion is that the normal outputs of instrument channels in nuclear plants can be monitored over a fuel cycle while the plant is operating to determine calibration drift in the field sensors and associated signal conversion and signal conditioning equipment. The procedure for on-line calibration tests involving calculating the deviation of each instrument channel from the best estimate of the process parameter that the instrument is measuring. Methods were evaluated for determining the best estimate. Deviation of each signal from the best estimate is updated frequently while the plant is operating and plotted vs time for entire fuel cycle, thereby providing time history plots that can reveal channel drift and other anomalies. Any instrument channel that exceeds allowable drift or channel accuracy band is then scheduled for calibration during a refueling outage or sooner. This provides calibration test results at the process operating point, one of the most critical points of the channel operation. This should suffice for most narrow-range instruments, although the calibration of some instruments can be verified at other points throughout their range. It should be pointed out that the calibration of some process signals such as the high pressure coolant injection flow in BWRs, which are normally off- scale during plant operation, can not be tested on-line

  3. Goals and instruments of land policy and the growth and development of cities

    OpenAIRE

    Maruška Šubic Kovač

    2001-01-01

    Instruments of land policies are tied to its goals, as well as defined relations on property and law as set in the Constitution. Since these relations have changed in Slovenia, the instruments of land policy also have to change. When devising particular instruments, basic principles have to be respected, which are the starting point for particular procedures. Only adequate legally defined instruments of land policies can be implemented in practice and affect the growth and development of citi...

  4. Solar Constant (SOLCON) Experiment: Ground Support Equipment (GSE) software development

    Science.gov (United States)

    Gibson, M. Alan; Thomas, Susan; Wilson, Robert

    1991-01-01

    The Solar Constant (SOLCON) Experiment, the objective of which is to determine the solar constant value and its variability, is scheduled for launch as part of the Space Shuttle/Atmospheric Laboratory for Application and Science (ATLAS) spacelab mission. The Ground Support Equipment (GSE) software was developed to monitor and analyze the SOLCON telemetry data during flight and to test the instrument on the ground. The design and development of the GSE software are discussed. The SOLCON instrument was tested during Davos International Solar Intercomparison, 1989 and the SOLCON data collected during the tests are analyzed to study the behavior of the instrument.

  5. Reliability of patient specific instrumentation in total knee arthroplasty.

    Science.gov (United States)

    Jennart, Harold; Ngo Yamben, Marie-Ange; Kyriakidis, Theofylaktos; Zorman, David

    2015-12-01

    The aim of this study was to compare the precision between Patient Specific Instrumentation (PSI) and Conventional Instrumentation (CI) as determined intra-operatively by a pinless navigation system. Eighty patients were included in this prospective comparative study and they were divided into two homogeneous groups. We defined an original score from 6 to 30 points to evaluate the accuracy of the position of the cutting guides. This score is based on 6 objective criteria. The analysis indicated that PSI was not superior to conventional instrumentation in the overall score (p = 0.949). Moreover, no statistically significant difference was observed for any individual criteria of our score. Level of evidence II.

  6. Goals and instruments of land policy and the growth and development of cities

    Directory of Open Access Journals (Sweden)

    Maruška Šubic Kovač

    2001-01-01

    Full Text Available Instruments of land policies are tied to its goals, as well as defined relations on property and law as set in the Constitution. Since these relations have changed in Slovenia, the instruments of land policy also have to change. When devising particular instruments, basic principles have to be respected, which are the starting point for particular procedures. Only adequate legally defined instruments of land policies can be implemented in practice and affect the growth and development of cities in Slovenia.

  7. Angle measurement with laser feedback instrument.

    Science.gov (United States)

    Chen, Wenxue; Zhang, Shulian; Long, Xingwu

    2013-04-08

    An instrument for angle measurement based on laser feedback has been designed. The measurement technique is based on the principle that when a wave plate placed into a feedback cavity rotates, its phase retardation varies. Phase retardation is a function of the rotating angle of the wave plate. Hence, the angle can be converted to phase retardation. The phase retardation is measured at certain characteristic points identified in the laser outputting curve that are then modulated by laser feedback. The angle of a rotating object can be measured if it is connected to the wave plate. The main advantages of this instrument are: high resolution, compact, flexible, low cost, effective power, and fast response.

  8. Remote Instrumentation for eScience and Related Aspects

    CERN Document Server

    Lawenda, Marcin; Meyer, Norbert; Pugliese, Roberto; Węglarz, Jan; Zappatore, Sandro

    2012-01-01

    Making scientific instruments a manageable resource over distributed computing infrastructures such as the grid has been a key focal point of e-science research in recent years. It is now known by the generic term ‘remote instrumentation’, and is the subject of this useful volume that covers a range of perspectives on the topic reflected by the contributions to the 2010 workshop on remote instrumentation held in Poznań, Poland. E-science itself is a complex set of disciplines requiring computationally intensive distributed operations, high-speed networking, and collaborative working tools. As such, it is most often (and correctly) associated with grid- and cloud-computing infrastructures and middleware. The contributions to this publication consider broader aspects of the theme of remote instrumentation applied to e-science, as well as exploring related technologies that enable the implementation of truly distributed and coordinated laboratories. Among the topics discussed are remote instrumentation and ...

  9. The ViewPoint radioprotection supervision workstation

    International Nuclear Information System (INIS)

    Gaultier, E.

    2009-01-01

    The author briefly presents the ViewPoint supervision global solution which incorporates audio and video advanced technologies to manage radioprotection operational measurements. Data can be transmitted by-wire or wireless. It can integrate a large number of radioprotection measurement instruments, such as a belt for the monitoring of physiological parameters (body temperature, breathing rhythm, body posture)

  10. Development of quality control and instrumentation performance metrics for diffuse optical spectroscopic imaging instruments in the multi-center clinical environment

    Science.gov (United States)

    Keene, Samuel T.; Cerussi, Albert E.; Warren, Robert V.; Hill, Brian; Roblyer, Darren; Leproux, AnaÑ--s.; Durkin, Amanda F.; O'Sullivan, Thomas D.; Haghany, Hosain; Mantulin, William W.; Tromberg, Bruce J.

    2013-03-01

    Instrument equivalence and quality control are critical elements of multi-center clinical trials. We currently have five identical Diffuse Optical Spectroscopic Imaging (DOSI) instruments enrolled in the American College of Radiology Imaging Network (ACRIN, #6691) trial located at five academic clinical research sites in the US. The goal of the study is to predict the response of breast tumors to neoadjuvant chemotherapy in 60 patients. In order to reliably compare DOSI measurements across different instruments, operators and sites, we must be confident that the data quality is comparable. We require objective and reliable methods for identifying, correcting, and rejecting low quality data. To achieve this goal, we developed and tested an automated quality control algorithm that rejects data points below the instrument noise floor, improves tissue optical property recovery, and outputs a detailed data quality report. Using a new protocol for obtaining dark-noise data, we applied the algorithm to ACRIN patient data and successfully improved the quality of recovered physiological data in some cases.

  11. A GC Instrument Simulator

    Science.gov (United States)

    Armitage, D. Bruce

    1999-02-01

    the difference between the boiling point of the component and the temperature of the column. The polarity difference between the column packing and the component is also used to modify the retention time. The retention time decreases as the difference between the boiling point of the component and the temperature of the column increases, and retention time increases as the polarity of the component approaches the polarity of the column. If the temperature of the column is too low, a warning message is given and the chromatogram does not show that component. There is no "carry-over" to the next chromatogram, as might be the case for an actual instrument. Carrier-gas flow rate is fixed and is not part of the retention-time calculation. Because of this latter condition and the method used to determine retention time, this simulator is not useful for gas chromatography method development and is not intended for such use. The purpose of the simulator is to give a beginning student experience in what happens as column temperature is varied, why one might need temperature programming, why an autosampler might be useful, and the pitfalls of "smart" integrators. When students make mistakes in instrument setup with the simulator the consequences are not damaging to the simulator but might cause serious problems with a real instrument. Hardware and Software Requirements Hardware and software requirements for A GC Instrument Simulator are shown in Table 1. right> right> Shown (right to left) are the main instrument control window and the manual injection window from A GC Instrument Simulator.

  12. Believing in Your In-Line NDA Instrumentation

    International Nuclear Information System (INIS)

    Hodge, C.A.

    2002-01-01

    A new feature in a processing line at the Savannah River Site (SRS) was the addition of fixed NaI detectors located at strategic points in the processing line. There are many uses of this instrumentation: Process control, MC and A, and criticality safety. In this particular application, there were 23 such strategic points identified. The data can be collected and analyzed in real time at a central point located outside any Radiation Buffer Area. This also allows the data to be collected without sampling or protective equipment requirements. The cost savings in time, cost, and timely production provided by this system are well established. This paper presents an anecdotal story regarding this particular application

  13. For Earth into space: The German Spacelab Mission D-2

    Science.gov (United States)

    Sahm, P. R.; Keller, M. H.; Schiewe, B.

    The Spacelab Mission D-2 successfully lifted off from Kennedy Space Center on April 26, 1993. With 88 experiments on board covering eleven different research disciplines it was a very ambitious mission. Besides materials and life science subjects, the mission also encompassed astronomy, earth observation, radiation physics and biology, telecommunication, automation and robotics. Notable results were obtained in almost all cases. To give some examples of the scientific output, building upon results obtained in previous missions (FSLP, D1) diffusion in melts was broadly represented delivering most precise data on the atomic mobility within various liquids, and crystal growth experiments (the largest gallium arsenide crystal grown by the floating zone technique, so far obtained anywhere, was one of the results), biological cell growth experiments were continued (for example, beer yeast cultures, continuing their growth on earth, delivered a qualitatively superior brewery result), the human physiology miniclinic configuration ANTHRORACK gave novel insights concerning cardiovascular, pulmonary, and renal (fluid volume determining) factors. Astronomical experiments yielded insights into our own galaxy within the ultra violet spectrum, earth observation experiments delivered the most precise resolution data superimposed by thematic mapping of many areas of the Earth, and the robotics experiment brought a remarkable feature in that a flying object was caught by the space robot, which was only achieved through several innovative advances during the time of experiment preparation. The eight years of preparation were also beneficial in another sense. Several discoveries have been made, and various technology transfers into ground-based processes were verified. To name the outstanding ones, in the materials science a novel bearing materials production process was developped, a patent granted for an improved high temperature heating chamber; with life sciences a new hormone

  14. The compatibility of flexible instruments under the Kyoto Protocol

    International Nuclear Information System (INIS)

    Jepma, C.J.; Van der Gaast, W.P.; Woerdman, E.

    1998-01-01

    The compatibility of the Kyoto Protocol flexible instruments and the lessons that can be learned form the AIJ-phase (AIJ stands for Activities Implemented Jointly) are discussed. The key point to be made is that there may be various applications of flexible instruments which can create situations where the various instruments would crowd out each other. On the other hand, applying flexible instruments may create a leverage for Parties in terms of achieving domestic environmental objectives. In addition, several issues related to the implementation of Joint Implementation (JI) , Clean Development Mechanism (CDM) and international emissions trading are discussed. The issues concern mainly those that have been included in the working programme on flexible instruments for CoP4 and CoP5 (CoP stands for Convention of Parties). As such the report discusses the consequences of possible negotiations outcomes at CoP for the effectiveness of flexible instruments, Parties' capabilities to achieve their Kyoto Protocol commitments cost-effectively, and the role of the private sector on the national and international credits markets(s). 106 refs

  15. Guaranteeing Pointing Performance of the SDO Sun-Pointing Controllers in Light of Nonlinear Effects

    Science.gov (United States)

    Starin, Scott R.; Bourkland, Kristin L.

    2007-01-01

    The Solar Dynamics Observatory (SDO) mission is the first Space Weather Research Network mission, part of NASA s Living With a Star program.1 This program seeks to understand the changing Sun and its effects on the Solar System, life, and society. To this end, the SDO spacecraft will carry three Sun-observing instruments to geosynchronous orbit: Helioseismic and Magnetic Imager (HMI), led by Stanford University; Atmospheric Imaging Assembly (AIA), led by Lockheed Martin Space and Astrophysics Laboratory; and Extreme Ultraviolet Variability Experiment (EVE), led by the University of Colorado. Links describing the instruments in detail may be found through the SDO web site.2 The basic mission goals are to observe the Sun for a very high percentage of the 5-year mission (10-year goal) with long stretches of uninterrupted observations and with constant, high-data-rate transmission to a dedicated ground station. These goals guided the design of the spacecraft bus that will carry and service the three-instrument payload. At the time of this publication, the SDO spacecraft bus is well into the integration and testing phase at the NASA Goddard Space Flight Center (GSFC). A three-axis stabilized attitude control system (ACS) is needed both to point at the Sun accurately and to keep the roll about the Sun vector correctly positioned. The ACS has four reaction wheel modes and 2 thruster actuated modes. More details about the ACS in general and the control modes in particular can be found in Refs. [3-6]. All four of SDO s wheel-actuated control modes involve Sun-pointing controllers, as might be expected from such a mission. Science mode, during which most science data is collected, uses specialized guide telescopes to point accurately at the Sun. Inertial mode has two sub-modes, one tracks a Sun-referenced target orientation, and another maintains an absolute (star-referenced) target orientation, that both employ a Kalman filter to process data from a digital Sun sensor and

  16. Instrumentation requirements from the user's view

    International Nuclear Information System (INIS)

    Harsha, P.T.

    1988-01-01

    The use of combustor diagnostics is considered from the point of view of demonstration of performance of an airbreathing hypersonic engine. The basic need is seen to be that of providing the data necessary to verify performance predictions for the engine as installed in the airplane. This necessitates the use of a diagnostics capability that can provide the inputs required by the computational analyses that will be used to assess this performance. Because of the cost of ground test facilities, a premium is placed on measurement technique reliability and redundancy of instrumentation. A mix of nonintrusive optical techniques and probe-based measurements is seen to be the best approach using current diagnostics capability; one such instrument mix is outlined for a ramjet/scramjet test program. 11 references

  17. Development of ultrasonic instrument 'UT1000 Series'

    International Nuclear Information System (INIS)

    Ogura, Yukio; Ikeda, Toshimichi

    1984-01-01

    The ultrasonic flaw detectors with 'A-scope indication' have been frequently used as the means for confirming the soundness of structures and equipments, but there are problems in their operational, quantifying and recording capabilities. Recently, the digital ultrasonic measuring instrument of touch panel type ''UT 1000 Series'' has been developed, which resolves these problems by a single effort. This measuring instrument is that of portable type, which gives the digital output of measured results in real time only by lightly touching the peak point of an echo on the Brown tube. This instrument contains the rich software for measurement, and can measure the positions and dimensions of defects and the pressure on contact surfaces with high accuracy. 'A-scope indication' is the indication with an oscilloscope taking the intensity of echo and the propagation time of ultrasonic waves on the ordinate and abscissa, respectively. There are three types of the instrument, that is, for detecting defects, for measuring contact surface pressure and for both purposes. The size of the instrument is 240 mm width, 350 mm length and 175 mm height, and the weight is 8.5 kgf. The specification, function and features of the ultrasonic flaw detector, touch panel, gain setter, key board, microcomputer and others are reported. (Kako, I.)

  18. The Gamma-Ray Burst Polarimeter - POLAR onboard the China’s Spacelab “Tiangong-2”

    Science.gov (United States)

    Sun, Jianchao; BAO, T. W.; BATSCH, T.; BRITVITCH, I.; CADOUX, F.; DONG, Y. W.; GAUVIN, N.; HAJDAS, W.; KOLE, M.; LECHANOINE-LELUC, C.; LI, L.; MARCINKOWSKI, R.; ORSI, S.; POHL, M.; PRODUIT, N.; RAPIN, D.; RUTCZYNSKA, A.; RYBKA, D.; SZABELSKI, J.; WANG, R. J.; WU, B. B.; XIAO, H. L.; ZHANG, S. N.; ZHANG, Y. J.; ZWOLINSKA, A.

    2015-08-01

    POLAR is a novel compact space-borne Compton polarimeter conceived for a precise measurement of hard X-ray/Gamma-ray polarization and optimized for the detection of the prompt emission of Gamma-Ray Bursts (GRB) in the energy range 50 - 500 keV. The future detailed measurement of the polarization of GRB will lead to a better understanding of its radiation region geometry and emission mechanisms. Thanks to its remarkable properties on large effective area, field of view (4.14 sr or 1/3 of the visible sky) and obvious modulation factor, POLAR will be able to reach a minimum detectable polarization (1-σ level) of about 3% for several GRB measurements per year. POLAR consists of 25 detector modular units (DMU). Each DMU is composed of 64 low-Z plastic scintillator bars, read out by a flat-panel multi-anode photomultipliers and ASIC front-end electronics. The incoming photons undergo Compton scattering in the bars and produce a modulation pattern. Simulations and hard X-ray synchrotron radiation experiments have shown that the polarization degree and angle can be retrieved from this pattern with the accuracy necessary for pinning down the GRB mechanisms. A full flight model of POLAR has been constructed, in view of a flight on the Chinese spacelab TG-2 expected in 2016. The design of POLAR, Monte-Carlo simulation analysis as well as the performance test results will be all addressed in details in this talk.

  19. A simple model explaining super-resolution in absolute optical instruments

    Science.gov (United States)

    Leonhardt, Ulf; Sahebdivan, Sahar; Kogan, Alex; Tyc, Tomáš

    2015-05-01

    We develop a simple, one-dimensional model for super-resolution in absolute optical instruments that is able to describe the interplay between sources and detectors. Our model explains the subwavelength sensitivity of a point detector to a point source reported in previous computer simulations and experiments (Miñano 2011 New J. Phys.13 125009; Miñano 2014 New J. Phys.16 033015).

  20. Automated and continuously operating acid dew point measuring instrument for flue gases

    Energy Technology Data Exchange (ETDEWEB)

    Reckmann, D.; Naundorf, G.

    1986-06-01

    Design and operation is explained for a sulfuric acid dew point indicator for continuous flue gas temperature control. The indicator operated successfully in trial tests over several years with brown coal, gas and oil combustion in a measurement range of 60 to 180 C. The design is regarded as uncomplicated and easy to manufacture. Its operating principle is based on electric conductivity measurement on a surface on which sulfuric acid vapor has condensed. A ring electrode and a PtRh/Pt thermal element as central electrode are employed. A scheme of the equipment design is provided. Accuracy of the indicator was compared to manual dew point sondes manufactured by Degussa and showed a maximum deviation of 5 C. Manual cleaning after a number of weeks of operation is required. Fly ash with a high lime content increases dust buildup and requires more frequent cleaning cycles.

  1. Using RF Smart Points for the Improvement of Metrological Activities

    Directory of Open Access Journals (Sweden)

    Claudio de Capua

    2007-03-01

    Full Text Available This work describes the realization of a “radio-frequency identification system” for the improvement of the activities of a metrological laboratory. Some radio-frequency modules, called by the authors RF Smart Points (“radio-frequency smart points”, have been designed to store into their memories all data which are necessary for the instruments tracking (the type of instruments, their identification numbers or serial numbers, the manufacturer, the date when they have been admitted to the installed base of the laboratory, their working state, the elapsed time from the last calibration procedure. The insertion of the data and the inquiry of the instruments are executed by the technical staff of the laboratory through a PDA (Personal Digital Assistant or a PC, which manage the radio-frequency communication by using the RS 232 interface for sending messages to a RF Transceiver. The executable software for managing the communication between the Smart Points and the “PDA/PC-Controllers” is realized in LabVIEW graphical programming environment.

  2. Neutron scattering instrumentation. A guide to future directions

    International Nuclear Information System (INIS)

    Crawford, R.K.

    2001-01-01

    Many of the neutron scattering instruments being designed or built now are the first generation of pulsed source instruments to provide nearly optimal scattering angle coverage with good spatial resolution in a single setting of the instrument while making full use of modern optics to maximize the useful flux on the sample. Spectacular gains have resulted from such optimization, but in most of these cases there is little room for further large improvements. However, other types of pulsed source instruments are currently less well optimized, and there is room for significant improvements in these types of pulsed source instruments. Several examples will illustrate these points. In the longer term, we can expect source strengths to continue to increase, but only slowly. However, we can expect new science and new ways of doing experiments to emerge. Many of these changes will be driven by enhancements in sample environment capabilities leading to more innovative sample conditions and to efficient parametric studies. Kinetic studies and parametric studies will take on much greater roles with the high data rates now available. Implications of these trends will be discussed. (author)

  3. 3D printing of surgical instruments for long-duration space missions.

    Science.gov (United States)

    Wong, Julielynn Y; Pfahnl, Andreas C

    2014-07-01

    The first off-Earth fused deposition modeling (FDM) 3D printer will explore thermoplastic manufacturing capabilities in microgravity. This study evaluated the feasibility of FDM 3D printing 10 acrylonitrile butadiene styrene (ABS) thermoplastic surgical instruments on Earth. Three-point bending tests compared stiffness and yield strength between FDM 3D printed and conventionally manufactured ABS thermoplastic. To evaluate the relative speed of using four printed instruments compared to conventional instruments, 13 surgeons completed simulated prepping, draping, incising, and suturing tasks. Each surgeon ranked the performance of six printed instruments using a 5-point Likert scale. At a thickness of 5.75 mm or more, the FDM printing process had a less than 10% detrimental effect on the tested yield strength and stiffness of horizontally printed ABS thermoplastic relative to conventional ABS thermoplastic. Significant weakness was observed when a bending load was applied transversely to a 3D printed layer. All timed tasks were successfully performed using a printed sponge stick, towel clamp, scalpel handle, and toothed forceps. There was no substantial difference in time to completion of simulated surgical tasks with control vs. 3D printed instruments. Of the surgeons, 100%, 92%, 85%, 77%, 77%, and 69% agreed that the printed smooth and tissue forceps, curved and straight hemostats, tissue and right angle clamps, respectively, would perform adequately. It is feasible to 3D print ABS thermoplastic surgical instruments on Earth. Loadbearing structures were designed to be thicker, when possible. Printing orientations were selected so that the printing layering direction of critical structures would not be transverse to bending loads.

  4. Mobile Instruments Measure Atmospheric Pollutants

    Science.gov (United States)

    2009-01-01

    As a part of NASA's active research of the Earth s atmosphere, which has included missions such as the Atmospheric Laboratory of Applications and Science (ATLAS, launched in 1992) and the Total Ozone Mapping Spectrometer (TOMS, launched on the Earth Probe satellite in 1996), the Agency also performs ground-based air pollution research. The ability to measure trace amounts of airborne pollutants precisely and quickly is important for determining natural patterns and human effects on global warming and air pollution, but until recent advances in field-grade spectroscopic instrumentation, this rapid, accurate data collection was limited and extremely difficult. In order to understand causes of climate change and airborne pollution, NASA has supported the development of compact, low power, rapid response instruments operating in the mid-infrared "molecular fingerprint" portion of the electromagnetic spectrum. These instruments, which measure atmospheric trace gases and airborne particles, can be deployed in mobile laboratories - customized ground vehicles, typically - to map distributions of pollutants in real time. The instruments must be rugged enough to operate rapidly and accurately, despite frequent jostling that can misalign, damage, or disconnect sensitive components. By measuring quickly while moving through an environment, a mobile laboratory can correlate data and geographic points, revealing patterns in the environment s pollutants. Rapid pollutant measurements also enable direct determination of pollutant sources and sinks (mechanisms that remove greenhouse gases and pollutants), providing information critical to understanding and managing atmospheric greenhouse gas and air pollutant concentrations.

  5. Nuclear instrumentation for uranium exploration

    International Nuclear Information System (INIS)

    Sarma, Ch. V.N.; Sarma, C.V.R.; Sreehari, R.

    1999-01-01

    Instrumentation required for uranium exploration may be broadly classified based on surface and sub-surface measurement of gamma-ray intensity. Surface measurement of gross and spectral gamma intensity are carried out by employing portable Geiger Mueller/scintillation counters and four-channel spectrometers. Measurement of thoron ( 220 Rn) and radon ( 222 Rn) in the soil gas is being carried out by closed circuit technique using radon measuring system. Radiometric mapping of trenches, pits and mine-faces are carried out using shielded probe with 2π source geometry, whereas logging sonde with instruments through the steel armoured cable are employed for point to 4π geometry. Spectral borehole logging system with built-in multi-channel analyser (MCA) has been developed for the uranium exploration programme for AMD. Note-book PC based high sensitivity air-borne gamma-ray spectrometric survey system has been designed, developed and test flown. (author)

  6. Artificial intelligence programming with LabVIEW: genetic algorithms for instrumentation control and optimization.

    Science.gov (United States)

    Moore, J H

    1995-06-01

    A genetic algorithm for instrumentation control and optimization was developed using the LabVIEW graphical programming environment. The usefulness of this methodology for the optimization of a closed loop control instrument is demonstrated with minimal complexity and the programming is presented in detail to facilitate its adaptation to other LabVIEW applications. Closed loop control instruments have variety of applications in the biomedical sciences including the regulation of physiological processes such as blood pressure. The program presented here should provide a useful starting point for those wishing to incorporate genetic algorithm approaches to LabVIEW mediated optimization of closed loop control instruments.

  7. Nuclear instrumentation for the industrial measuring systems

    International Nuclear Information System (INIS)

    Normand, S.

    2010-01-01

    This work deals with nuclear instrumentation and its application to industry, power plant fuel reprocessing plant and finally with homeland security. The first part concerns the reactor instrumentation, in-core and ex-core measurement system. Ionization Uranium fission chamber will be introduced with their acquisition system especially Campbell mode system. Some progress have been done on regarding sensors failure foresee. The second part of this work deals with reprocessing plant and associated instrumentation for nuclear waste management. Proportional counters techniques will be discussed, especially Helium-3 counter, and new development on electronic concept for reprocessing nuclear waste plant (one electronic for multipurpose acquisition system). For nuclear safety and security for human and homeland will be introduce. First we will explain a new particular approach on operational dosimetric measurement and secondly, we will show new kind of organic scintillator material and associated electronics. Signal treatment with real time treatment is embedded, in order to make neutron gamma discrimination possible even in solid organic scintillator. Finally, the conclusion will point out future, with most trends in research and development on nuclear instrumentation for next years. (author) [fr

  8. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. An inspector-instrument interface design that allows communication of procedures, responses, and results between the instrument and user is presented. This capability has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  9. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  10. Electrolytic preconcentration in instrumental analysis.

    Science.gov (United States)

    Sioda, R E; Batley, G E; Lund, W; Wang, J; Leach, S C

    1986-05-01

    The use of electrolytic deposition as a separation and preconcentration step in trace metal analysis is reviewed. Both the principles and applications of the technique are dealt with in some detail. Electrolytic preconcentration can be combined with a variety of instrumental techniques. Special attention is given to stripping voltammetry, potentiometric stripping analysis, different combinations with atomic-absorption spectrometry, and the use of flow-through porous electrodes. It is pointed out that the electrolytic preconcentration technique deserves more extensive use as well as fundamental investigation.

  11. PERFORMANCE CONFIRMATION IN-SITU INSTRUMENTATION

    International Nuclear Information System (INIS)

    N.T. Raczka

    2000-01-01

    The purpose of this document is to identify and analyze the types of in-situ instruments and methods that could be used in support of the data acquisition portion of the Performance Confirmation (PC) program at the potential nuclear waste repository at Yucca Mountain. The PC program will require geomechanical , geophysical, thermal, and hydrologic instrumentation of several kinds. This analysis is being prepared to document the technical issues associated with each type of measurement during the PC period. This analysis utilizes the ''Performance Confirmation Input Criteria'' (CRWMS M andO 1999a) as its starting point. The scope of this analysis is primarily on the period after the start of waste package emplacement and before permanent closure of the repository, a period lasting between 15 and 300 years after last package emplacement (Stroupe 2000, Attachment 1, p. 1). The primary objectives of this analysis are to: (1) Review the design criteria as presented in the ''Performance Confirmation Input Criteria'' (CRWMS M andO 1999a). The scope of this analysis will be limited to the instrumentation related to parameters that require continuous monitoring of the conditions underground. (2) Preliminary identification and listing of the data requirements and parameters as related to the current repository layout in support of PC monitoring. (3) Preliminary identification of methods and instrumentation for the acquisition of the required data. Although the ''Performance Confirmation Input Criteria'' (CRWMS M andO 1999a) defines a broad range of data that must be obtained from a variety of methods, the focus of this analysis is on instrumentation related to the performance of the rock mass and the formation of water in the repository environment, that is obtainable from in-situ observation, testing, and monitoring

  12. Bright point study

    International Nuclear Information System (INIS)

    Tang, F.; Harvey, K.; Bruner, M.; Kent, B.; Antonucci, E.

    1982-01-01

    Transition region and coronal observations of bright points by instruments aboard the Solar Maximum Mission and high resolution photospheric magnetograph observations on September 11, 1980 are presented. A total of 31 bipolar ephemeral regions were found in the photosphere from birth in 9.3 hours of combined magnetograph observations from three observatories. Two of the three ephemeral regions present in the field of view of the Ultraviolet Spectrometer-Polarimeter were observed in the C IV 1548 line. The unobserved ephemeral region was determined to be the shortest-lived (2.5 hr) and lowest in magnetic flux density (13G) of the three regions. The Flat Crystal Spectrometer observed only low level signals in the O VIII 18.969 A line, which were not statistically significant to be positively identified with any of the 16 ephemeral regions detected in the photosphere. In addition, the data indicate that at any given time there lacked a one-to-one correspondence between observable bright points and photospheric ephemeral regions, while more ephemeral regions were observed than their counterparts in the transition region and the corona

  13. Managing the Complexity of Human/Machine Interactions in Computerized Learning Environments: Guiding Students' Command Process through Instrumental Orchestrations

    Science.gov (United States)

    Trouche, Luc

    2004-01-01

    After an introduction which addresses some basic questions, this article is organized around three points: (1) The theoretical framework of the so-called "instrumental approach" which has been a theme in the last two CAME symposia; (2) A consideration of two processes ("instrumentalization" and "instrumentation") which interact in the…

  14. Evaluation of two disinfection/sterilization methods on silicon rubber-based composite finishing instruments.

    Science.gov (United States)

    Lacerda, Vánia A; Pereira, Leandro O; Hirata JUNIOR, Raphael; Perez, Cesar R

    2015-12-01

    To evaluate the effectiveness of disinfection/sterilization methods and their effects on polishing capacity, micomorphology, and composition of two different composite fiishing and polishing instruments. Two brands of finishing and polishing instruments (Jiffy and Optimize), were analyzed. For the antimicrobial test, 60 points (30 of each brand) were used for polishing composite restorations and submitted to three different groups of disinfection/sterilization methods: none (control), autoclaving, and immersion in peracetic acid for 60 minutes. The in vitro tests were performed to evaluate the polishing performance on resin composite disks (Amelogen) using a 3D scanner (Talyscan) and to evaluate the effects on the points' surface composition (XRF) and micromorphology (MEV) after completing a polishing and sterilizing routine five times. Both sterilization/disinfection methods were efficient against oral cultivable organisms and no deleterious modification was observed to point surface.

  15. Implementation of quality assurance in the manufacture of radiation measuring instruments

    International Nuclear Information System (INIS)

    Erath, W.; Maushart, R.

    1993-01-01

    Contrary to a general belief, quality assurance in an instrument manufacturing plant comprises considerably more than the testing of instruments and components. Quality assurance programs according to the ISO 9000 standards are part of the general quality policy of a company, comprising management, manufacturing, sales, and service. A description of the quality assurance research and development is given, and the practical execution with regard to calibration of contamination monitors is pointed out in detail. (orig.) [de

  16. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  17. Planck 2015 results: II. Low Frequency Instrument data processings

    DEFF Research Database (Denmark)

    Ade, P. A R; Aghanim, N.; Ashdown, M.

    2016-01-01

    We present an updated description of the Planck Low Frequency Instrument (LFI) data processing pipeline, associated with the 2015 data release. We point out the places where our results and methods have remained unchanged since the 2013 paper and we highlight the changes made for the 2015 release...

  18. Direct concurrent comparison of multiple pediatric acute asthma scoring instruments.

    Science.gov (United States)

    Johnson, Michael D; Nkoy, Flory L; Sheng, Xiaoming; Greene, Tom; Stone, Bryan L; Garvin, Jennifer

    2017-09-01

    Appropriate delivery of Emergency Department (ED) treatment to children with acute asthma requires clinician assessment of acute asthma severity. Various clinical scoring instruments exist to standardize assessment of acute asthma severity in the ED, but their selection remains arbitrary due to few published direct comparisons of their properties. Our objective was to test the feasibility of directly comparing properties of multiple scoring instruments in a pediatric ED. Using a novel approach supported by a composite data collection form, clinicians categorized elements of five scoring instruments before and after initial treatment for 48 patients 2-18 years of age with acute asthma seen at the ED of a tertiary care pediatric hospital ED from August to December 2014. Scoring instruments were compared for inter-rater reliability between clinician types and their ability to predict hospitalization. Inter-rater reliability between clinician types was not different between instruments at any point and was lower (weighted kappa range 0.21-0.55) than values reported elsewhere. Predictive ability of most instruments for hospitalization was higher after treatment than before treatment (p < 0.05) and may vary between instruments after treatment (p = 0.054). We demonstrate the feasibility of comparing multiple clinical scoring instruments simultaneously in ED clinical practice. Scoring instruments had higher predictive ability for hospitalization after treatment than before treatment and may differ in their predictive ability after initial treatment. Definitive conclusions about the best instrument or meaningful comparison between instruments will require a study with a larger sample size.

  19. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  20. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  1. STS-56 ATLAS-2 pallet is lowered into OV-103's payload bay at KSC's OPF HB-3

    Science.gov (United States)

    1993-01-01

    STS-56 Atmospheric Laboratory for Applications and Science 2 (ATLAS-2) unpressurized spacelab pallet and the mission peculiar support structure (MPESS)-mounted Shuttle Pointed Autonomous Research Tool for Astronomy 201 (SPARTAN-201) are lowered into the payload bay (PLB) of Discovery, Orbiter Vehicle (OV) 103, at the Kennedy Space Center's (KSC's) Orbiter Processing Facility (OPF) High Bay 3 (HB-3) during preflight integration. Clean-suited technicians monitor the progress and operation of the overhead crane from which the ATLAS-2 pallet/SPARTAN MPESS are suspended. ATLAS-2 equipment and instruments include: the igloo (cylindrical tank - front and center); the inverters and pump package (far right); port conical scan sensor (next to pump package at far right); the millimeter-wave atmospheric sounder (MAS) antenna (pallet center, just above igloo); the starboard conical scan sensor (small cylinder at far left); and the atmospheric trace module spectroscopy (ATMOS) (box behind conical se

  2. Standard audit procedure for continuous emission monitors and ambient air monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-06-15

    The instruments were published in an operational policy manual in 2009. This policy aims to introduce standard audit criteria that can be used to determine if continuous emission monitors and ambient air monitoring devices are operating within acceptable parameters. Before delivering upscale points of the instrument to be audited, each one of the audit equipment used in the field is required to be at normal operating conditions. Before the beginning of the audit, each one of the meteorological and flow measurement equipment is required to be conditioned to current conditions. If the audit fails, the instrument will have to be audited quarterly. The establishment of specific procedures based on instrument manufacturer or certifying body operational standards is required in the case of non-continuous monitoring instruments presenting operational principles outside of the audit procedures listed in the document.

  3. Teaching computer interfacing with virtual instruments in an object-oriented language.

    Science.gov (United States)

    Gulotta, M

    1995-01-01

    LabVIEW is a graphic object-oriented computer language developed to facilitate hardware/software communication. LabVIEW is a complete computer language that can be used like Basic, FORTRAN, or C. In LabVIEW one creates virtual instruments that aesthetically look like real instruments but are controlled by sophisticated computer programs. There are several levels of data acquisition VIs that make it easy to control data flow, and many signal processing and analysis algorithms come with the software as premade VIs. In the classroom, the similarity between virtual and real instruments helps students understand how information is passed between the computer and attached instruments. The software may be used in the absence of hardware so that students can work at home as well as in the classroom. This article demonstrates how LabVIEW can be used to control data flow between computers and instruments, points out important features for signal processing and analysis, and shows how virtual instruments may be used in place of physical instrumentation. Applications of LabVIEW to the teaching laboratory are also discussed, and a plausible course outline is given. PMID:8580361

  4. A framework for assessing Health Economic Evaluation (HEE) quality appraisal instruments.

    Science.gov (United States)

    Langer, Astrid

    2012-08-16

    Health economic evaluations support the health care decision-making process by providing information on costs and consequences of health interventions. The quality of such studies is assessed by health economic evaluation (HEE) quality appraisal instruments. At present, there is no instrument for measuring and improving the quality of such HEE quality appraisal instruments. Therefore, the objectives of this study are to establish a framework for assessing the quality of HEE quality appraisal instruments to support and improve their quality, and to apply this framework to those HEE quality appraisal instruments which have been subject to more scrutiny than others, in order to test the framework and to demonstrate the shortcomings of existing HEE quality appraisal instruments. To develop the quality assessment framework for HEE quality appraisal instruments, the experiences of using appraisal tools for clinical guidelines are used. Based on a deductive iterative process, clinical guideline appraisal instruments identified through literature search are reviewed, consolidated, and adapted to produce the final quality assessment framework for HEE quality appraisal instruments. The final quality assessment framework for HEE quality appraisal instruments consists of 36 items organized within 7 dimensions, each of which captures a specific domain of quality. Applying the quality assessment framework to four existing HEE quality appraisal instruments, it is found that these four quality appraisal instruments are of variable quality. The framework described in this study should be regarded as a starting point for appraising the quality of HEE quality appraisal instruments. This framework can be used by HEE quality appraisal instrument producers to support and improve the quality and acceptance of existing and future HEE quality appraisal instruments. By applying this framework, users of HEE quality appraisal instruments can become aware of methodological deficiencies

  5. The Ukrainian Bandura as a Musical Instrument of the Chordophone Group

    Directory of Open Access Journals (Sweden)

    Violetta Dutchak

    2017-10-01

    Full Text Available The article examines the characteristics of the bandura as a plucked chordophone. A comparative analysis of the researches undertaken by outstanding musicologists, performers, ethno-organologists S. Lyudkevych, E. Hornbostel, C. Sachs, H. Khotkevych, Z. Shtokalko, and others is carried out. The morphology of the instrument and the main stages in its evolution are discussed. The stable and mobile elements of the bandura’s structure and tuning are described. The technical characteristics of the instrument in different periods of its evolution and the achievements of the bandura makers and bandurists of Ukraine and the Ukrainian diaspora are analyzed. The common and distinguishing features of the bandura and some kindred instruments are pointed out.

  6. Thermal simulations of the STIX instrument for ESA Solar Orbiter mission

    Science.gov (United States)

    Białek, Agata; Severyn, Karol; Grassmann, Kamil; Orleańskii, Piotr; Skup, Konrad R.; Arnold, Nicolas; Gröbelbauer, Hans-Peter; Hurford, Gordon J.; Krucker, Samuel; Bauer, Svend-Marian; Mann, Gottfied; Önel, Hakan; Bernet, Adeline; Blecha, Luc; Grimm, Oliver; Limousin, Olivier; Martignac, Jerome; Meuris, Aline

    2013-07-01

    The ESA Solar Orbiter mission, planned to be launched in 2017, is going to study the Sun with ten different instruments including the Spectrometer/Telescope for Imaging X-rays - STIX. The thermal environment on the elliptical orbit around the Sun - 0.28 AU at perihelion and 0.952 AU at aphelion - is extreme, where at one point of the orbit is very hot, while on another very cold. That makes the requirements for the heat fluxes exchanged between each instrument and the spacecraft, as well as between the instrument - subsystems, very restrictive. Here the authors discuss the thermal design with respect to the defined requirements and present the results of the thermal analyses performed with ESATAN TMS software.

  7. The Bering Target Tracking Instrumentation

    DEFF Research Database (Denmark)

    Denver, Troelz; Jørgensen, John Leif; Betto, Maurizio

    2003-01-01

    The key science instrument on the Bering satellite mission is a relative small telescope with an entrance aperture of 300 mm and a focal length between 500 and 1000 mm. The detection of potential targets is performed by one of the target scanning advanced stellar compasses (ASCs). This procedure...... results in a simple prioritized list of right ascension, declination, proper motion and intensity of each prospective target. The telescope itself has a dedicated ASC Camera Head Unit (CHU) mounted on the secondary mirror, largely co-aligned with the telescope. This CHU accurately determines the telescope......'s pointing direction. To achieve fast tracking over a large solid angle, the telescope pointing is achieved by means of a folding mirror in the optical pathway. When a prospective target approaches the telescope FOV, the ASC on the secondary will guide the folding mirror into position such that the target...

  8. Instrumentness for Creativity - Mediation, Materiality & Metonymy

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege; Breinbjerg, Morten; Pold, Søren

    2007-01-01

    in use beyond what is initially designed for. The paper performs a conceptual investigation into qualities in software interfaces that support creativity, supported by analysis of, and interviews with, musical composers. Instrumentness is explained through discussions of materiality and metonymy...... as central strategies for computer mediated creativity. The paper is contributing to an investigation of the aesthetics of use in relation to software, pointing to alternative values, differing from traditional usability, which are also relevant in creative work outside art and music composition....

  9. Instrumentation report 1: specification, design, calibration, and installation of instrumentation for an experimental, high-level, nuclear waste storage facility

    International Nuclear Information System (INIS)

    Brough, W.G.; Patrick, W.C.

    1982-01-01

    The Spent Fuel Test-Climax (SFT-C) is being conducted 420 m underground at the Nevada Test Site under the auspices of the US Department of Energy. The test facility houses 11 spent fuel assemblies from an operating commercial nuclear reactor and numerous other thermal sources used to simulate the near-field effects of a large repository. We developed a large-scale instrumentation plan to ensure that a sufficient quality and quantity of data were acquired during the three- to five-year test. These data help satisfy scientific, operational, and radiation safety objectives. Over 800 data channels are being scanned to measure temperature, electrical power, radiation, air flow, dew point, stress, displacement, and equipment operation status (on/off). This document details the criteria, design, specifications, installation, calibration, and current performance of the entire instrumentation package

  10. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  11. SMAP Instrument Mechanical System Engineering

    Science.gov (United States)

    Slimko, Eric; French, Richard; Riggs, Benjamin

    2013-01-01

    The Soil Moisture Active Passive (SMAP) mission, scheduled for launch by the end of 2014, is being developed to measure the soil moisture and soil freeze/thaw state on a global scale over a three-year period. The accuracy, resolution, and global coverage of SMAP measurements are invaluable across many science and applications disciplines including hydrology, climate, carbon cycle, and the meteorological, environment, and ecology applications communities. The SMAP observatory is composed of a despun bus and a spinning instrument platform that includes both a deployable 6 meter aperture low structural frequency Astromesh reflector and a spin control system. The instrument section has engendered challenging mechanical system issues associated with the antenna deployment, flexible antenna pointing in the context of a multitude of disturbances, spun section mass properties, spin control system development, and overall integration with the flight system on both mechanical and control system levels. Moreover, the multitude of organizations involved, including two major vendors providing the spin subsystem and reflector boom assembly plus the flight system mechanical and guidance, navigation, and control teams, has led to several unique system engineering challenges. Capturing the key physics associated with the function of the flight system has been challenging due to the many different domains that are applicable. Key interfaces and operational concepts have led to complex negotiations because of the large number of organizations that integrate with the instrument mechanical system. Additionally, the verification and validation concerns associated with the mechanical system have had required far-reaching involvement from both the flight system and other subsystems. The SMAP instrument mechanical systems engineering issues and their solutions are described in this paper.

  12. Accurately Localize and Recognize Instruments with Substation Inspection Robot in Complex Environments

    Directory of Open Access Journals (Sweden)

    Hui Song

    2014-07-01

    Full Text Available This paper designs and develops an automatic detection system in the substation environment where complex and multi-inspecting objects exist. The inspection robot is able to fix and identify the objects quickly using a visual servo control system. This paper focuses on the analysis of fast lockup and recognition method of the substation instruments based on an improved Adaboost algorithm. The robot adjusts its position to the best view point and best resolution for the instrument in real-time. The dial and pointer of the instruments are detected with an improved Hough algorithm, and the angle of the pointer is converted to the corresponding readings. The experimental results indicate that the inspection robot can fix and identify the substation instruments quickly, and has a wide range of practical applications.

  13. Instrument Remote Control via the Astronomical Instrument Markup Language

    Science.gov (United States)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  14. Characterization of the Effect of Wing Surface Instrumentation on UAV Airfoil Performance

    Science.gov (United States)

    Ratnayake, Nalin A.

    2009-01-01

    Recently proposed flight research at NASA Dryden Flight Research Center (DFRC) has prompted study into the aerodynamic effects of modifications made to the surfaces of laminar airfoils. The research is focused on the high-aspect ratio, laminar-flow type wings commonly found on UAVs and other aircraft with a high endurance requirement. A broad range of instrumentation possibilities, such as structural, pressure, and temperature sensing devices may require the alteration of the airfoil outer mold line as part of the installation process. This study attempts to characterize the effect of installing this additiona1 instrumentation on key airfoil performance factors, such as transition location, lift and drag curves, and stall point. In particular, the general case of an airfoil that is channeled in the spanwise direction is considered, and the impact on key performance characteristics is assessed. Particular attention is focused on exploring the limits of channel depth and low-Reynolds number on performance and stall characteristics. To quantify the effect of increased skin friction due to premature transition caused by protruding or recessed instrumentation, two simplified, conservative scenarios are used to consider two potential sources of diaturbance: A) that leading edge alterations would cause linearly expanding areas (triangles) of turbulent flow on both surfaces of the wing upstream of the natural transition point, and B) that a channel or bump on the upper surface would trip turbulent flow across the whole upper surface upstream of the natural transition point. A potentially more important consideration than the skin friction drag increment is the change in overall airfoil performance due to the installation of instrumentation along most of the wingspan. To quantify this effect, 2D CFD simulations of the flow over a representative mid-span airfoil section were conducted in order to assess the change in lift and drag curves for the airfoil in the presence of

  15. Electronic instrumentation system for pulsed neutron measurements

    International Nuclear Information System (INIS)

    Burda, J.; Igielski, A.; Kowalik, W.

    1982-01-01

    An essential point of pulsed neutron measurement of thermal neutron parameters for different materials is the registration of the thermal neutron die-away curve after a fast neutron bursts have been injected into the system. An electronic instrumentation system which is successfully applied for pulsed neutron measurements is presented. An important part of the system is the control unit which has been designed and built in the Laboratory of Neutron Parameters of Materials. (author)

  16. Instrumentation of a manually programmed neutron diffractometer

    DEFF Research Database (Denmark)

    Hansen, K.B.; Neisig, K.E.

    1966-01-01

    This paper describes essentially the digital part of the instrumentation for a neutron diffractometer in which the measuring procedure is governed by a control unit involving a fixed number of program points. A simultaneously running test program monitors the information transfer from the data...... sources and to the print-out in table form. The experimental conditions must be set by a panel switch selected program, which allows a desired parameter program to be executed....

  17. Radium issues at Hunters Point Annex

    International Nuclear Information System (INIS)

    Dean, S.M.

    1994-01-01

    Radium was a common source of illumination used in numerous instruments and gauges for military equipment prior to 1970. As a result of its many military applications radium 226 is now a principle radionuclide of concern at military base closures sites throughout the United States. This is an overview of the site characterization strategy employed and a potential site remediation technology being considered at a radium contaminated landfill at Hunters Point Annex, a former U.S. Navy shipyard in San Francisco, California

  18. Set point calculations for RAPID project

    International Nuclear Information System (INIS)

    HICKMAN, G.L.

    1999-01-01

    This change modifies accuracies of the water skid temperature indicators and controllers TIC-410. TI-412, TI-413, TIC-413, TIC-414, TIC-415. Acknowledges ability to calibrate PQIT-367 and modifies the accuracy of that instrument loop. Adjusts the allowable dilution dater temperature from 110-130F to 102-130F based on PCP Rev.2 and adjusts alarm and other points to reflect that change. Removes revision numbers for all references. Numerous additional changes (fixing typos, more detailed explanations etc.) throughout

  19. Measurements on pointing error and field of view of Cimel-318 Sun photometers in the scope of AERONET

    Directory of Open Access Journals (Sweden)

    B. Torres

    2013-08-01

    Full Text Available Sensitivity studies indicate that among the diverse error sources of ground-based sky radiometer observations, the pointing error plays an important role in the correct retrieval of aerosol properties. The accurate pointing is specially critical for the characterization of desert dust aerosol. The present work relies on the analysis of two new measurement procedures (cross and matrix specifically designed for the evaluation of the pointing error in the standard instrument of the Aerosol Robotic Network (AERONET, the Cimel CE-318 Sun photometer. The first part of the analysis contains a preliminary study whose results conclude on the need of a Sun movement correction for an accurate evaluation of the pointing error from both new measurements. Once this correction is applied, both measurements show equivalent results with differences under 0.01° in the pointing error estimations. The second part of the analysis includes the incorporation of the cross procedure in the AERONET routine measurement protocol in order to monitor the pointing error in field instruments. The pointing error was evaluated using the data collected for more than a year, in 7 Sun photometers belonging to AERONET sites. The registered pointing error values were generally smaller than 0.1°, though in some instruments values up to 0.3° have been observed. Moreover, the pointing error analysis shows that this measurement can be useful to detect mechanical problems in the robots or dirtiness in the 4-quadrant detector used to track the Sun. Specifically, these mechanical faults can be detected due to the stable behavior of the values over time and vs. the solar zenith angle. Finally, the matrix procedure can be used to derive the value of the solid view angle of the instruments. The methodology has been implemented and applied for the characterization of 5 Sun photometers. To validate the method, a comparison with solid angles obtained from the vicarious calibration method was

  20. Unified instrumentation for determining fissile and radioactive materials

    International Nuclear Information System (INIS)

    Voronov, V.L.; Gorokhov, V.A.; Drozdov, V.Yu.; Morozov, O.S.; Novikov, V.M.

    1999-01-01

    The instrumentation is aimed to equip various facilities: nuclear facilities (including radioactive plant and nuclear material storages), border check stations at the customs, transport junctions, administrative buildings and other facilities. The monitor under design are based on the gamma-spectrometric method of radiation monitoring which consists in recording and analyzing characteristics of X-ray and gamma-sources power spectra within the range of 40-3000 keV at the background level whose value is measured and taken into account during the signal analysis. The designed universal set of instrumentation based on common technical solutions and metrological support plus its small dimensions allows to install it actually in any check point without any significant changes in the room lay-out to facilitate its maintenance [ru

  1. Problems in developing an instrument for the rapid assessment of personality status.

    Science.gov (United States)

    Van Horn, E; Manley, C; Leddy, D; Cicchetti, D; Tyrer, P

    2000-06-01

    To assess the validity of a quick assessment instrument (10 minutes) for assessing personality status, the Rapid Personality Assessment Schedule (PAS-R). The PAS-R was evaluated in psychotic patients recruited in one of the centres involved in a multicentre randomised controlled trial of intensive vs standard case management (the UK700 case management trial). Patients were assessed using both a full version of the PAS (PAS-I - ICD version) and the PAS-R. The weighted kappa statistic was used to gauge the (criterion-related) validity of the PAS-R using the PAS-I as the gold standard. Both measure code personality status using a four-point rating of severity in addition to recording individual categories of personality disorder. One hundred fifty-five (77%) of 201 patients recruited were assessed with both instruments. The weighted kappa statistic was 0.31, suggesting only moderate agreement between the PAS-I and PAS-R instruments under the four-point rating format, and 0.39 for the dichotomous personality disorder/no disorder separation. The sensitivity (64%) and specificity (82%) of the PAS-R in predicting PAS-I personality disorder were as satisfactory as for other screening instruments but still somewhat disappointing, and the PAS-R had an overall diagnostic accuracy of 78%. The PAS-R is a quick and rough method of detecting personality abnormality but is not a substitute for a fuller assessment.

  2. Invited Article: Deep Impact instrument calibration.

    Science.gov (United States)

    Klaasen, Kenneth P; A'Hearn, Michael F; Baca, Michael; Delamere, Alan; Desnoyer, Mark; Farnham, Tony; Groussin, Olivier; Hampton, Donald; Ipatov, Sergei; Li, Jianyang; Lisse, Carey; Mastrodemos, Nickolaos; McLaughlin, Stephanie; Sunshine, Jessica; Thomas, Peter; Wellnitz, Dennis

    2008-09-01

    Calibration of NASA's Deep Impact spacecraft instruments allows reliable scientific interpretation of the images and spectra returned from comet Tempel 1. Calibrations of the four onboard remote sensing imaging instruments have been performed in the areas of geometric calibration, spatial resolution, spectral resolution, and radiometric response. Error sources such as noise (random, coherent, encoding, data compression), detector readout artifacts, scattered light, and radiation interactions have been quantified. The point spread functions (PSFs) of the medium resolution instrument and its twin impactor targeting sensor are near the theoretical minimum [ approximately 1.7 pixels full width at half maximum (FWHM)]. However, the high resolution instrument camera was found to be out of focus with a PSF FWHM of approximately 9 pixels. The charge coupled device (CCD) read noise is approximately 1 DN. Electrical cross-talk between the CCD detector quadrants is correctable to <2 DN. The IR spectrometer response nonlinearity is correctable to approximately 1%. Spectrometer read noise is approximately 2 DN. The variation in zero-exposure signal level with time and spectrometer temperature is not fully characterized; currently corrections are good to approximately 10 DN at best. Wavelength mapping onto the detector is known within 1 pixel; spectral lines have a FWHM of approximately 2 pixels. About 1% of the IR detector pixels behave badly and remain uncalibrated. The spectrometer exhibits a faint ghost image from reflection off a beamsplitter. Instrument absolute radiometric calibration accuracies were determined generally to <10% using star imaging. Flat-field calibration reduces pixel-to-pixel response differences to approximately 0.5% for the cameras and <2% for the spectrometer. A standard calibration image processing pipeline is used to produce archival image files for analysis by researchers.

  3. Invited Article: Deep Impact instrument calibration

    International Nuclear Information System (INIS)

    Klaasen, Kenneth P.; Mastrodemos, Nickolaos; A'Hearn, Michael F.; Farnham, Tony; Groussin, Olivier; Ipatov, Sergei; Li Jianyang; McLaughlin, Stephanie; Sunshine, Jessica; Wellnitz, Dennis; Baca, Michael; Delamere, Alan; Desnoyer, Mark; Thomas, Peter; Hampton, Donald; Lisse, Carey

    2008-01-01

    Calibration of NASA's Deep Impact spacecraft instruments allows reliable scientific interpretation of the images and spectra returned from comet Tempel 1. Calibrations of the four onboard remote sensing imaging instruments have been performed in the areas of geometric calibration, spatial resolution, spectral resolution, and radiometric response. Error sources such as noise (random, coherent, encoding, data compression), detector readout artifacts, scattered light, and radiation interactions have been quantified. The point spread functions (PSFs) of the medium resolution instrument and its twin impactor targeting sensor are near the theoretical minimum [∼1.7 pixels full width at half maximum (FWHM)]. However, the high resolution instrument camera was found to be out of focus with a PSF FWHM of ∼9 pixels. The charge coupled device (CCD) read noise is ∼1 DN. Electrical cross-talk between the CCD detector quadrants is correctable to <2 DN. The IR spectrometer response nonlinearity is correctable to ∼1%. Spectrometer read noise is ∼2 DN. The variation in zero-exposure signal level with time and spectrometer temperature is not fully characterized; currently corrections are good to ∼10 DN at best. Wavelength mapping onto the detector is known within 1 pixel; spectral lines have a FWHM of ∼2 pixels. About 1% of the IR detector pixels behave badly and remain uncalibrated. The spectrometer exhibits a faint ghost image from reflection off a beamsplitter. Instrument absolute radiometric calibration accuracies were determined generally to <10% using star imaging. Flat-field calibration reduces pixel-to-pixel response differences to ∼0.5% for the cameras and <2% for the spectrometer. A standard calibration image processing pipeline is used to produce archival image files for analysis by researchers.

  4. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  5. Optimization criteria for control and instrumentation systems in nuclear power plants

    International Nuclear Information System (INIS)

    Gonzalez, A.J.

    1978-01-01

    The system of dose limitation recently recommended by the International Commission on Radiation Protection includes, as a base for deciding what is reasonably achievable in dose reduction, the optimization of radioprotection systems. This paper, after compiling relevant points in the new system, discusses the application of optimization to control and instrumentation of radioprotection systems in nuclear power plants. Furthermore, an extension of the optimization criterion to nuclear safety systems is also presented and its application to control and instrumentation is discussed; systems including majority logics are particularly scrutinized. Finally, eventual regulatory implications are described. (author)

  6. Swift Burst Alert Telescope (BAT) Instrument Response

    International Nuclear Information System (INIS)

    Parsons, A.; Barthelmy, S.; Cummings, J.; Gehrels, N.; Hullinger, D.; Krimm, H.; Markwardt, C.; Tueller, J.; Fenimore, E.; Palmer, D.; Sato, G.; Takahashi, T.; Nakazawa, K.; Okada, Y.; Takahashi, H.; Suzuki, M.; Tashiro, M.

    2004-01-01

    The Burst Alert Telescope (BAT), a large coded aperture instrument with a wide field-of-view (FOV), provides the gamma-ray burst triggers and locations for the Swift Gamma-Ray Burst Explorer. In addition to providing this imaging information, BAT will perform a 15 keV - 150 keV all-sky hard x-ray survey based on the serendipitous pointings resulting from the study of gamma-ray bursts, and will also monitor the sky for transient hard x-ray sources. For BAT to provide spectral and photometric information for the gamma-ray bursts, the transient sources and the all-sky survey, the BAT instrument response must be determined to an increasingly greater accuracy. This paper describes the spectral models and the ground calibration experiments used to determine the BAT response to an accuracy suitable for gamma-ray burst studies

  7. Proceedings: Instrumentation and control test reduction workshop

    International Nuclear Information System (INIS)

    1991-09-01

    Instrumentation and control (I ampersand C) surveillance and testing is a significant contributor to operations and management costs. Several techniques to eliminate or reduce manual testing requirements could reduce costs while improving plant safety and performance. I ampersand C test reduction was the subject of this 1991 workshop. The workshop covered test elimination, test reduction, test automation, and relevant standards and benefits. The conclusions of the workshop were the following: More utility information sharing is important. There is a significant amount of information available throughout the industry, but it is not available in a concise, useable form. An I ampersand C utility users group is needed to address items such as instrument calibration reduction, set-point methodologies, and other current I ampersand C issues. The workshop was well received. The timing is right to initiate actions to reduce testing

  8. National symposium and workshop on optical platforms, Huntsville, AL, June 12-14, 1984, Proceedings

    International Nuclear Information System (INIS)

    Wyman, C.L.

    1984-01-01

    The conference is concerned with space-based observatories (including future systems), interplanetary observation platforms, Space Station optical utilization, orbital earth viewing systems, and Spacelab's use as an observations platform. Attention is given to the pointing system for the space telescope, the Advanced X-ray Astrophysics Facility, the conceptual definition of the Space IR Telescope Facility's spacecraft, satellite servicing in light of the Solar Maximum Repair Mission, a large deployable reflector telescope concept, moon-based astronomical observatories, Space Station-based remote sensing of the earth, optical systems is geosynchronous orbit, multispectral linear array detector technology, Spacelab-based space plasma and materials processing investigations, and space construction technology for large space observatories. Also discussed are military optical platforms for sea, land and air stationing

  9. Nanosurveyor 2: A Compact Instrument for Nano-Tomography at the Advanced Light Source

    Science.gov (United States)

    Celestre, Richard; Nowrouzi, Kasra; Shapiro, David A.; Denes, Peter; Joseph, John M.; Schmid, Andreas; Padmore, Howard A.

    2017-06-01

    The Advanced Light Source has developed a compact tomographic microscope based on soft x-ray ptychography for the study of nanoscale materials [1,2]. The microscope utilizes the sample manipulator mechanism from a commercial TEM coupled with laser interferometric feedback for zone plate positioning and a fast frame rate charge-coupled device detector for soft x-ray diffraction measurements. The microscope has achieved point to point (25 nm steps) scan rates of greater than 120 Hz with a positioning accuracy of better than 1 nm RMS. The instrument will enable the use of commercially available sample holders compatible with FEI transmission electron microscopes thus also allowing in-situ measurement of samples using both soft x-rays and electrons. This instrument is a refinement of a currently commissioned instrument called The Nanosurveyor, which has demonstrated resolution of better than 10 nm in two dimensions using 750 eV x-rays. Once moved to the new Coherent Scattering and Microscopy beamline it will enable spectromicroscopy and tomography of nano-materials with wavelength limited spatial resolution.

  10. On-Orbit Performance of the Helioseismic and Magnetic Imager Instrument onboard the Solar Dynamics Observatory

    Science.gov (United States)

    Hoeksema, J. T.; Baldner, C. S.; Bush, R. I.; Schou, J.; Scherrer, P. H.

    2018-03-01

    The Helioseismic and Magnetic Imager (HMI) instrument is a major component of NASA's Solar Dynamics Observatory (SDO) spacecraft. Since commencement of full regular science operations on 1 May 2010, HMI has operated with remarkable continuity, e.g. during the more than five years of the SDO prime mission that ended 30 September 2015, HMI collected 98.4% of all possible 45-second velocity maps; minimizing gaps in these full-disk Dopplergrams is crucial for helioseismology. HMI velocity, intensity, and magnetic-field measurements are used in numerous investigations, so understanding the quality of the data is important. This article describes the calibration measurements used to track the performance of the HMI instrument, and it details trends in important instrument parameters during the prime mission. Regular calibration sequences provide information used to improve and update the calibration of HMI data. The set-point temperature of the instrument front window and optical bench is adjusted regularly to maintain instrument focus, and changes in the temperature-control scheme have been made to improve stability in the observable quantities. The exposure time has been changed to compensate for a 20% decrease in instrument throughput. Measurements of the performance of the shutter and tuning mechanisms show that they are aging as expected and continue to perform according to specification. Parameters of the tunable optical-filter elements are regularly adjusted to account for drifts in the central wavelength. Frequent measurements of changing CCD-camera characteristics, such as gain and flat field, are used to calibrate the observations. Infrequent expected events such as eclipses, transits, and spacecraft off-points interrupt regular instrument operations and provide the opportunity to perform additional calibration. Onboard instrument anomalies are rare and seem to occur quite uniformly in time. The instrument continues to perform very well.

  11. Measures and time points relevant for post-surgical follow-up in patients with inflammatory arthritis: a pilot study

    Directory of Open Access Journals (Sweden)

    Tägil Magnus

    2009-05-01

    Full Text Available Abstract Background Rheumatic diseases commonly affect joints and other structures in the hand. Surgery is a traditional way to treat hand problems in inflammatory rheumatic diseases with the purposes of pain relief, restore function and prevent progression. There are numerous measures to choose from, and a combination of outcome measures is recommended. This study evaluated if instruments commonly used in rheumatologic clinical practice are suitable to measure outcome of hand surgery and to identify time points relevant for follow-up. Methods Thirty-one patients (median age 56 years, median disease duration 15 years with inflammatory rheumatic disease and need for post-surgical occupational therapy intervention formed this pilot study group. Hand function was assessed regarding grip strength (Grippit, pain (VAS, range of motion (ROM (Signals of Functional Impairment (SOFI and grip ability (Grip Ability Test (GAT. Activities of daily life (ADL were assessed by means of Disabilities of the Arm, Shoulder and Hand Outcome (DASH and Canadian Occupational Performance Measure (COPM. The instruments were evaluated by responsiveness and feasibility; follow-up points were 0, 3, 6 and 12 months. Results All instruments showed significant change at one or more follow-up points. Satisfaction with activities (COPM showed the best responsiveness (SMR>0.8, while ROM measured with SOFI had low responsiveness at most follow-up time points. The responsiveness of the instruments was stable between 6 and 12 month follow-up which imply that 6 month is an appropriate time for evaluating short-term effect of hand surgery in rheumatic diseases. Conclusion We suggest a core set of instruments measuring pain, grip strength, grip ability, perceived symptoms and self-defined daily activities. This study has shown that VAS pain, the Grippit instrument, GAT, DASH symptom scale and COPM are suitable outcome instruments for hand surgery, while SOFI may be a more insensitive

  12. Instrument performance in bone density testing at five Australian centres

    Energy Technology Data Exchange (ETDEWEB)

    Khan, K M; Saul, A; Wark, J D [Royal Melbourne Hospital, Parkville, VIC (Australia). Department of Medicine; Henzell, S L [Charles Gairdner Hospital, Perth, WA (Australia). Department of Endocrinology and Diabetes; Broderick, C [University of NSW, Sydney, NSW (Australia); Prince, R L [University of Western Australia, Perth, WA. (Australia). Department of Medicine; Lomman, J [Bone Densitometry Technologist, Ashford, SA (Australia)

    1997-10-01

    Using a multicentre reliability study the accuracy and short- and long-term precision of dual-energy X-ray absorptiometry (DXA) in vitro was compared on five instruments. Measures were performed using pencil beam mode on four Hologic QDR- 2000 densitometers and one Hologic QDR-1000/W (Hologic Inc, Waltham, MA). Short-term precision of bone mineral density measurement was less than 0.5% for spine phantoms (n= 10 for each centre, mean intrasite coefficient of variation [CV] 0.39{+-}0.09% [SD]) and for hip phantoms (n=10 for each centre, mean intrasite coefficient of variation [CV] 0.34{+-}0.10% [SD]). Between-centre measurement (n=10 for each phantom) of a single spine phantom and a single hip phantom (specified mineral contents - 58.5 g and 38.6 g, respectively) revealed ranges of bone mineral content of 57.7-58.1 g (all-point CV=0.52%) and 37.1-37.8 g (all-point CV=0.70%), respectively. When results from pairs of machines were compared there were statistically different mean BMD results for the majority of the ten possible pairings for both spine and hip measurements. Each study centre measured in vitro stability of phantom BMD measurements over a one year period (n=45-283, median 157 for spine; and n=0-262, median 38, for hip); CVs ranged from 0.38 % to 0.53% for the spine measurements and from 0.38 % to 0.54% for the hip measurements. The mean all-point accuracy of the spine phantom measurements was 99.1% and the hip phantom measurements was 96.7%. It is concluded that across a number of instruments assessed in this study, DXA demonstrates in vitro all-point precision of 0.5% for the spine phantom and 0.7% for the hip phantom. The instrument demonstrates accuracy of greater than 99% at the spine and 96% at the hip (authors). 14 refs., 3 tabs., 4 figs.

  13. New Platforms for Suborbital Astronomical Observations and In Situ Atmospheric Measurements: Spacecraft, Instruments, and Facilities

    Science.gov (United States)

    Rodway, K.; DeForest, C. E.; Diller, J.; Vilas, F.; Sollitt, L. S.; Reyes, M. F.; Filo, A. S.; Anderson, E.

    2014-12-01

    Suborbital astronomical observations have over 50 years' history using NASA's sounding rockets and experimental space planes. The new commercial space industry is developing suborbital reusable launch vehicles (sRLV's) to provide low-cost, flexible, and frequent access to space at ~100 km altitude. In the case of XCOR Aerospace's Lynx spacecraft, the vehicle design and capabilities work well for hosting specially designed experiments that can be flown with a human-tended researcher or alone with the pilot on a customized mission. Some of the first-generation instruments and facilities that will conduct solar observations on dedicated Lynx science missions include the SwRI Solar Instrument Pointing Platform (SSIPP) and Atsa Suborbital Observatory, as well as KickSat sprites, which are picosatellites for in situ atmospheric and solar phenomena measurements. The SSIPP is a demonstration two-stage pointed solar observatory that operates inside the Lynx cockpit. The coarse pointing stage includes the pilot in the feedback loop, and the fine stage stabilizes the solar image to achieve arcsecond class pointing. SSIPP is a stepping-stone to future external instruments that can operate with larger apertures and shorter wavelengths in the solar atmosphere. The Planetary Science Institute's Atsa Suborbital Observatory combines the strengths of ground-based observatories and space-based observing to create a facility where a telescope is maintained and used interchangeably with either in-house facility instruments or user-provided instruments. The Atsa prototype is a proof of concept, hand-guided camera that mounts on the interior of the Lynx cockpit to test target acquisition and tracking for human-operated suborbital astronomy. KickSat sprites are mass-producible, one inch printed circuit boards (PCBs) populated by programmable off the shelf microprocessors and radios for real time data transmission. The sprite PCBs can integrate chip-based radiometers, magnetometers

  14. Fuel fabrication instrumentation and control system overview

    International Nuclear Information System (INIS)

    Bennett, D.W.; Fritz, R.L.

    1980-10-01

    A process instrumentation and control system is being developed for automated fabrication of breeder reactor fuel at the Hanford Engineering Development Laboratory (HEDL) in Richland, Washington. The basic elements of the control system are a centralized computer system linked to distributed local computers, which direct individual process applications. The control philosophy developed for the equipment automation program stresses system flexibility and inherent levels of redundant control capabilities. Four different control points have been developed for each unit process operation

  15. netherland hydrological modeling instrument

    Science.gov (United States)

    Hoogewoud, J. C.; de Lange, W. J.; Veldhuizen, A.; Prinsen, G.

    2012-04-01

    Netherlands Hydrological Modeling Instrument A decision support system for water basin management. J.C. Hoogewoud , W.J. de Lange ,A. Veldhuizen , G. Prinsen , The Netherlands Hydrological modeling Instrument (NHI) is the center point of a framework of models, to coherently model the hydrological system and the multitude of functions it supports. Dutch hydrological institutes Deltares, Alterra, Netherlands Environmental Assessment Agency, RWS Waterdienst, STOWA and Vewin are cooperating in enhancing the NHI for adequate decision support. The instrument is used by three different ministries involved in national water policy matters, for instance the WFD, drought management, manure policy and climate change issues. The basis of the modeling instrument is a state-of-the-art on-line coupling of the groundwater system (MODFLOW), the unsaturated zone (metaSWAP) and the surface water system (MOZART-DM). It brings together hydro(geo)logical processes from the column to the basin scale, ranging from 250x250m plots to the river Rhine and includes salt water flow. The NHI is validated with an eight year run (1998-2006) with dry and wet periods. For this run different parts of the hydrology have been compared with measurements. For instance, water demands in dry periods (e.g. for irrigation), discharges at outlets, groundwater levels and evaporation. A validation alone is not enough to get support from stakeholders. Involvement from stakeholders in the modeling process is needed. There fore to gain sufficient support and trust in the instrument on different (policy) levels a couple of actions have been taken: 1. a transparent evaluation of modeling-results has been set up 2. an extensive program is running to cooperate with regional waterboards and suppliers of drinking water in improving the NHI 3. sharing (hydrological) data via newly setup Modeling Database for local and national models 4. Enhancing the NHI with "local" information. The NHI is and has been used for many

  16. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  17. Cloud Instrument Powered by Solar Cell Sends Data to Pachube

    Directory of Open Access Journals (Sweden)

    Doru Ursutiu

    2010-11-01

    Full Text Available Despite the economic downturn, there have been quite a few new developments in the world of remote measurements lately. Tag4M (www.tag4m.com introduced the concept of cloud instrument where sensors connected to WiFi tags send data to off-the-shelf Access Points which are part of the WiFi infrastructure that exists in enterprises, retail outlets, factories, and warehouses. Access Points route the data to the Internet where specialized web applications receive the information for processing and display. One of these specialized web applications is Pachube, (http://www.pachube.com which bills itself as a “real-time data brokerage platform”. Pachube enables people to tag and share real time sensor data from objects, devices and spaces around the world. This article presents the pachube cloud instrument where sensors connected to Tag4M WiFi tags send digitized data to www.pachube.com for public display. The article contains very detailed analysis of the solar cell power source that is used to continuously power the Tag4M tag during this application. Cloud Instruments powered by solar cells enable people around the world to share real time sensor data using web pages on the Internet. This is a very interesting and exciting technology development that we want to bring to your attention.

  18. TMI-2 instrumentation and electrical program final evaluation report

    International Nuclear Information System (INIS)

    Mayo, C.W.; Huzdovich, J.W.; Roby, A.R.; Test, L.D.

    1986-11-01

    This report presents the authors collective opinions on the value to the nuclear industry of the various investigations performed at TMI-2 by the Instrumentation and Electrical Program. The authors demonstrate that more attention must be given to the prevention of moisture intrusion during design, construction, operation, and maintenance of a nuclear power plant. They also point out that, while basic engineering designs of instruments are more than adequate, the applications engineering and specifications could be improved. Finally, they show that advanced testing technology, exemplified by the Electrical Circuit Characterization and Diagnostics (ECCAD) System, may be very useful as a diagnostic tool when used as part of the testing or maintenance program in a nuclear power plant

  19. NCTM workshop splinter session, IR thermal measurement instruments

    Science.gov (United States)

    Kaplan, Herbert

    1989-06-01

    The splinter session dealing with commercial industrial thermal measurement state-of-the-hardware had a total attendance of 15. Two papers were presented in the splinter session as follows: (1) Development of an Infrared Imaging System for the Surface Tension Driven Convection Experiment, Alexander D. Pline, NASA LeRC; (2) A Space-qualified PtSi Thermal Imaging System, Robert W. Astheimer, Barnes Engineering Div., EDO Corp. In addition a brief description of SPRITE detector technology was presented by Richard F. Leftwich of Magnovox. As anticipated, the discussions were concerned mainly with thermal imaging figures of merit rather than those for point measurement instruments. The need for uniform guidelines whereby infrared thermal imaging instruments could be specified and evaluated was identified as most important, particularly where temperature measurements are required. Presently there are differences in the way different manufacturers present significant performance parameters in their instrument data sheets. Furthermore, the prospective user has difficulty relating these parameters to actual measurement needs, and procedures by which performance can be verified are poorly defined. The current availability of powerful thermal imaging diagnostic software was discussed.

  20. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  1. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  2. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  3. In-core flow measurement and calibration of gags using on-load instrumented stringers in a C.A.G.R. at Hinkley Point 'B'

    International Nuclear Information System (INIS)

    Harrison, W.E.; Carrick, I.H.

    1982-06-01

    The initial fuel loading of the first CAGR at Hinkley Point included 5 specially instrumented stringers (OLIS) each containing a flow-measuring venturi and additional thermocouples. Venturi absolute and differential pressures were measured by transducers mounted on the pile-cap. Transducers and thermocouples were routed to a computer/logger and processed into stringer performance data. The venturi was engineered to comply closely with appropriate British Standards but compromises were made to minimise interaction with other functions of the OLIS plug unit, justifying rig calibration of venturis to check for deviation in behaviour. High accuracy and reliability of the flow measuring system were established by thorough commissioning procedures. The transducers were selected for low sensitivity to their operational environment. Nevertheless calibration of all transducers was carried out both in laboratory and in-situ. Errors introduced by signal processing were identified and zero drift monitored. Pipe-runs were scrupulously leak-tested and leak sensitivity was evaluated. After one year re-calibration and recommissioning gave confidence of long term stability. Measurements of stringer behaviour were collected in a series of tests spanning the full range of both the setting of the channel flow control gags and the reactor power. Throughout these tests comprehensive monitoring, with intercalibration between the OLIS and comparison with installed reactor instrumentation has quantified residual error. These measurements were used to check the theoretical model used by the station for channel flow assessment. The excellent agreement obtained justified proceeding to the derivation of a universal gag resistance calibration applying to all power levels. In performance tests aimed at evaluation of overall generating efficiency, the theoretical model was used to make accurate estimates of reactor power and flow which agreed well with estimates based directly on further OLIS

  4. Les répétitifs, la machine et l’instrument

    Directory of Open Access Journals (Sweden)

    Johan Girard

    2011-03-01

    Full Text Available La poétique des compositeurs répétitifs américains Terry Riley, Steve Reich et Philip Glass repose sur des usages spécifiques de l’instrument de musique. C’est tout d’abord l’indigence des ressources instrumentales et le recours à des instruments de fortune, comme l’orgue électrique. C’est également l’usage de l’amplification dans la composition du timbre et le traitement percussif des instruments à clavier, en particulier chez Steve Reich. Enfin, le « transfert » de structures issues de la musique pour bande vers l’écriture traditionnelle détermine les choix et les usages de l’instrument, par des mises en boucle, des effets d’accumulation, un jeu sur l’indiscernabilité des timbres et une attention aux plus infimes détails émergeant de la répétitivité du jeu, de sorte que les choix esthétiques des trois compositeurs impliquent une gestion spécifique de l’instrument de musique.« Repetitive Music, the machine and the instrument ». The poetics of American repetitive composers Terry Riley, Steve Reich and Philip Glass are based on a specific use of musical instruments. First we can notice the use of indigent instrumental means and rudimentary instruments like the electric organ. Second we point out the use of amplification in timbre composition and the percussive use of keyboard instruments (particularly in Steve Reich’s work. Finally, a structural “transfer” from tape music to traditional musical composition determines the choices and uses of musical instruments, trough tape looping, accumulation effects and a play on timbre indiscernibility that brings attention to the most subtle details emerging from repetition, so that the three composers’ aesthetic choices imply a specific relation to musical instruments.

  5. Vision though afocal instruments: generalized magnification and eye-instrument interaction

    Science.gov (United States)

    Harris, William F.; Evans, Tanya

    2018-04-01

    In Gaussian optics all observers experience the same magnification, the instrument's angular magnification, when viewing distant objects though a telescope or other afocal instruments. However, analysis in linear optics shows that this is not necessarily so in the presence of astigmatism. Because astigmatism may distort and rotate images it is appropriate to work with generalized angular magnification represented by a 2 × 2 matrix. An expression is derived for the generalized magnification for an arbitrary eye looking through an arbitrary afocal instrument. With afocal instruments containing astigmatic refracting elements not all eyes experience the same generalized magnification; there is interaction between eye and instrument. Eye-instrument interaction may change as the instrument is rotated about its longitudinal axis, there being no interaction in particular orientations. A simple numerical example is given. For sake of completeness, expressions for generalized magnification are also presented in the case of instruments that are not afocal and objects that are not distant.

  6. Quality Assurance and Quality Control in Point-of-Care Testing.

    Science.gov (United States)

    Newman, Ashleigh W; Behling-Kelly, Erica

    2016-03-01

    With advancements in the standard of care in veterinary medicine and instrument technology, performing in-house laboratory work on a variety of point-of-care instruments, ranging from glucometers to benchtop chemistry analyzers, has become increasingly commonplace. However, the ability of an instrument to perform a test does not guarantee that those results are accurate. Ensuring that your in-clinic laboratory is providing reliable data requires a comprehensive plan that encompasses both common sense practices aimed at preventing errors at each stage of the testing process, as well as standard operating procedures to validate and monitor analyzer performance. These 2 arms of the plan are known as quality assurance and quality control. Although these concepts are typically out of the comfort zone for veterinarians, just as the thought of business management may deter some veterinarians from practice ownership, it is not beyond the capabilities of veterinarians to learn, understand, and incorporate them into their practice. The objectives of this article are to convey the importance of quality assurance and quality control, walk you through the American Society for Veterinary Clinical Pathology guidelines on this topic, and provide direction to additional resources for further education on this topic, all with the focus on point-of-care testing in the in-clinic laboratory. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Can Indian classical instrumental music reduce pain felt during venepuncture?

    Science.gov (United States)

    Balan, Rajiv; Bavdekar, S B; Jadhav, Sandhya

    2009-05-01

    Local anesthetic agent is not usually used to reduce pain experienced by children undergoing venepuncture. This study was undertaken to determine comparative efficacy of local anesthetic cream, Indian classical instrumental music and placebo, in reducing pain due to venepuncture in children. Children aged 5-12 yr requiring venepuncture were enrolled in a prospective randomized clinical trial conducted at a tertiary care center. They were randomly assigned to 3 groups: local anesthetic (LA), music or placebo (control) group. Eutactic mixture of local anesthetic agents (EMLA) and Indian classical instrumental music (raaga-Todi) were used in the first 2 groups, respectively. Pain was assessed independently by parent, patient, investigator and an independent observer at the time of insertion of the cannula (0 min) and at 1- and 5 min after the insertion using a Visual Analog Scale (VAS). Kruskal- Wallis and Mann-Whitney U tests were used to assess the difference amongst the VAS scores. Fifty subjects were enrolled in each group. Significantly higher VAS scores were noted in control (placebo) group by all the categories of observers (parent, patient, investigator, independent observer) at all time points. The VAS scores obtained in LA group were lowest at all time points. However, the difference between VAS scores in LA group were significantly lower than those in music group only at some time-points and with some categories of observers (parent: 1 min; investigator: 0-, 1-, 5 min and independent observer: 5 min). Pain experienced during venepuncture can be significantly reduced by using EMLA or Indian classical instrumental music. The difference between VAS scores with LA and music is not always significant. Hence, the choice between EMLA and music could be dictated by logistical factors.

  8. Validation of a Visionary Leadership Attitude Instrument Using Factor Analysis.

    Science.gov (United States)

    LeSourd, Sandra J.; And Others

    Findings from a study to develop and validate an instrument for the measurement of principals' attitudes toward visionary leadership are presented in this paper. Two leadership styles--visionary and managerial--were measured by a 35-item five-point Likert attitude scale. Questionnaires mailed to a random sample of 250 K-12 Nebraska and 250…

  9. Cape Point GAW Station Rn-222 detector: factors affecting sensitivity and accuracy

    CSIR Research Space (South Africa)

    Brunke, EG

    2002-05-01

    Full Text Available Specific factors of a baseline Rn-222 detector installed at Cape Point, South Africa, were studied with the aim of improving its performance. Direct sunlight caused air turbulence within the instrument, resulting in 13.6% variability...

  10. Development of a radiology faculty appraisal instrument by using critical incident interviewing.

    Science.gov (United States)

    Collins, J; Albanese, M A; Thakor, S K; Propeck, P A; Scanlan, K A

    1997-12-01

    To develop a valid and reliable radiology faculty appraisal instrument based on scientific methods. Fifteen radiology residents participated in critical incident interviewing. During a 1-hour interview, a resident was asked to describe five incidents each of effective and ineffective faculty behavior. Two investigators independently listened to the tape-recorded interviews, and two different investigators sorted the incidents into broad categories. A faculty appraisal instrument was developed by listing similar incidents under broad categories. A five-point rating scale was applied to each item. Content validity was assessed by resident and faculty critique of the appraisal instrument. A total of 168 incidents of faculty behavior were generated. The frequency with which similar incidents were reported was recorded. The most common behaviors reported were related to staff expertise and teaching. Interjudge reliability was good, as determined by computing K indices of agreement (overall K = 0.59). There was good agreement regarding instrument content validity among residents but not among faculty. Residents supported the use of the new appraisal instrument, but further tests of validity and reliability and faculty acceptance of the instrument will determine its usefulness as a tool for monitoring faculty teaching performance and making decisions regarding faculty promotion.

  11. Point-spread function in depleted and partially depleted CCDs

    International Nuclear Information System (INIS)

    Groom, D.E.; Eberhard, P.H.; Holland, S.E.; Levi, M.E.; Palaio, N.P.; Perlmutter, S.; Stover, R.J.; Wei, M.

    1999-01-01

    The point spread function obtainable in an astronomical instrument using CCD readout is limited by a number of factors, among them the lateral diffusion of charge before it is collected in the potential wells. They study this problem both theoretically and experimentally, with emphasis on the thick CCDs on high-resistivity n-type substrates being developed at Lawrence Berkeley National Laboratory

  12. Innovative operating modes and techniques for the spaceborne imaging radar-C instrument

    Science.gov (United States)

    Huneycutt, Bryan L.

    1990-01-01

    The operation of the spaceborne imaging radar-C (SIR-C) is discussed. The SIR-C instrument has been designed to obtain simultaneous multifrequency and simultaneous multipolarization radar images from a low earth orbit. It is a multiparameter imaging radar which will be flown during at least two different seasons. The instrument has been designed to operate in innovative modes such as the squint alignment mode, the extended aperture mode, the scansar mode, and the interferometry mode. The instrument has been designed to demonstrate innovative engineering techniques such as beam nulling for echo tracking, pulse-repetition frquency hopping for Doppler centroid tracking, generating the frequency step chirp for radar parameter flexibility, block floating point quantizing for data rate compression, and elevation beamwidth broadening for increasing the swath illumination.

  13. Methodology of adjustment point in the post treatment of gaseous effluents

    International Nuclear Information System (INIS)

    Vizuet G, J.; Molina, G.

    2005-01-01

    The methodology to determine the adjustment points of the monitoring system of gaseous discharges is based on the stipulations of the 10CFR20, which are expressed in terms of limit concentrations for the outstanding radionuclides, and of dose limits for the individuals members of the public. Besides the points of liberation properly said, like they are the chimneys of the reactor buildings and of turbine, the points of adjustment of the monitoring instrumentation that watches in real time the discharge of the Treatment system of output gases, to the HVAC of the waste building; they also undergo to the same methodology, with the approaches previously described. (Author)

  14. Pancreatitis Quality of Life Instrument: Development of a new instrument

    Directory of Open Access Journals (Sweden)

    Wahid Wassef

    2014-02-01

    Full Text Available Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors. Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use.

  15. Thermal and Alignment Analysis of the Instrument-Level ATLAS Thermal Vacuum Test

    Science.gov (United States)

    Bradshaw, Heather

    2012-01-01

    This paper describes the thermal analysis and test design performed in preparation for the ATLAS thermal vacuum test. NASA's Advanced Topographic Laser Altimeter System (ATLAS) will be flown as the sole instrument aboard the Ice, Cloud, and land Elevation Satellite-2 (ICESat-2). It will be used to take measurements of topography and ice thickness for Arctic and Antarctic regions, providing crucial data used to predict future changes in worldwide sea levels. Due to the precise measurements ATLAS is taking, the laser altimeter has very tight pointing requirements. Therefore, the instrument is very sensitive to temperature-induced thermal distortions. For this reason, it is necessary to perform a Structural, Thermal, Optical Performance (STOP) analysis not only for flight, but also to ensure performance requirements can be operationally met during instrument-level thermal vacuum testing. This paper describes the thermal model created for the chamber setup, which was used to generate inputs for the environmental STOP analysis. This paper also presents the results of the STOP analysis, which indicate that the test predictions adequately replicate the thermal distortions predicted for flight. This is a new application of an existing process, as STOP analyses are generally performed to predict flight behavior only. Another novel aspect of this test is that it presents the opportunity to verify pointing results of a STOP model, which is not generally done. It is possible in this case, however, because the actual pointing will be measured using flight hardware during thermal vacuum testing and can be compared to STOP predictions.

  16. Evaluation of surface characteristics of rotary nickel-titanium instruments produced by different manufacturing methods.

    Science.gov (United States)

    Inan, U; Gurel, M

    2017-02-01

    Instrument fracture is a serious concern in endodontic practice. The aim of this study was to investigate the surface quality of new and used rotary nickel-titanium (NiTi) instruments manufactured by the traditional grinding process and twisting methods. Total 16 instruments of two rotary NiTi systems were used in this study. Eight Twisted Files (TF) (SybronEndo, Orange, CA, USA) and 8 Mtwo (VDW, Munich, Germany) instruments were evaluated. New and used of 4 experimental groups were evaluated using an atomic force microscopy (AFM). New and used instruments were analyzed on 3 points along a 3 mm. section at the tip of the instrument. Quantitative measurements according to the topographical deviations were recorded. The data were statistically analyzed with paired samples t-test and independent samples t-test. Mean root mean square (RMS) values for new and used TF 25.06 files were 10.70 ± 2.80 nm and 21.58 ± 6.42 nm, respectively, and the difference between them was statistically significant (P instruments produced by twisting method (TF 25.06) had better surface quality than the instruments produced by traditional grinding process (Mtwo 25.06 files).

  17. Design of improved detection instrumentation for the annulus gas system for wolsong 2

    International Nuclear Information System (INIS)

    Kim, Seog Nam; Koo, Jun Mo; Chang, Ik Ho; Jung, Ho Chang; Han, Sang Joon

    1996-01-01

    The improved and advanced Annulus Gas System (AGS) has been developed for Wolsong 2 to satisfy the requirements of the regulatory body. The Atomic Energy Control Board (AECB) required a shorter detection time following a small leak from a pressure tube and/or calandria tube. This paper describes licensing requirements, functional requirements and detail design description for the AGS. The Wolsong unit No. 1 AGS was designed to operate as a stagnant system normally requiring only pressure regulation and having provisions for purging. The improved AGS involves the adoption of gas recirculation in AGS, duplication of dew point indicators with additional instrumentation and sampling provisions to prompt operator action. The improved system operates in the recirculation mode with continuous dew point measurement for leak detection. An AGS with improved detection instrumentation is provided. 8 refs., 3 figs. (author)

  18. Tool for identifying critical control points in embedded purchasing activities in SMEs

    NARCIS (Netherlands)

    Hagelaar, Geoffrey; Staal, Anne; Holman, Richard; Walhof, Gert

    2015-01-01

    This paper discusses risk and uncertainty aspects and proposes an assessment tool leading to identification of critical control points (CCPs) within purchasing-oriented activities of small and medium enterprises (SMEs). Identifying such CCPs is the basis for developing SME purchasing instruments to

  19. Engineering Analysis of the Recovered SAFOD Borehole Instrumentation

    International Nuclear Information System (INIS)

    Johnson, Wade

    2014-01-01

    The basic data set was acquired during 18 instrumentation setting tests conducted from 2004 through 2007 as part of SAFOD. Active hydrocarbon-rich water invaded the borehole because the borehole had not sealed at the bottom. For this reason, the water in the casing reached the cable head and caused a malfunction. Attempts were made to use better O rings, Krytox oil, and epoxy seal, but all failed. In most of these deployments, standard wire-line was used and the average failure time was two weeks. Based on design review, many improvements such as stainless tube encapsulate electric cables, all-metal seals, and Swageloks were applied. Setting of improved downhole instrument packages was carried out in the autumn of 2008. Still, these instruments could not endure the high temperature environment of 120 degrees Celsius for a long period of time, and all were offline in less than a month. A SAFOD engineering subcommittee was established in 2010 to investigate the problems caused through an examination of the removed instruments. It became clear that fluid including active hydrocarbons had invaded the stainless tubing from the seal part and caused all instruments to fail. Based on the above-mentioned experience, recommendations for the future are as follows. - Perform strict oversight of subcontractors. - Perform robust risk analysis and prepare a risk mitigation plan. - Multiple checks should be performed on points of failure by different people. - If possible, avoid the use of active electronics in environments like those in SAFOD. - Components must be rated for use in the temperature range of the environment in which they are to be used. - If a failure occurs, remove the instrumentation in a timely manner. - The SAFOD POD design was not inherently flawed but poorly implemented. (author)

  20. Radiation Budget Instrument (RBI) for JPSS-2

    Science.gov (United States)

    Georgieva, Elena; Priestley, Kory; Dunn, Barry; Cageao, Richard; Barki, Anum; Osmundsen, Jim; Turczynski, Craig; Abedin, Nurul

    2015-01-01

    Radiation Budget Instrument (RBI) will be one of five instruments flying aboard the JPSS-2 spacecraft, a polar-orbiting sun-synchronous satellite in Low Earth Orbit. RBI is a passive remote sensing instrument that will follow the successful legacy of the Clouds and Earth's Radiant Energy System (CERES) instruments to make measurement of Earth's short and longwave radiation budget. The goal of RBI is to provide an independent measurement of the broadband reflected solar radiance and Earth's emitted thermal radiance by using three spectral bands (Shortwave, Longwave, and Total) that will have the same overlapped point spread function (PSF) footprint on Earth. To ensure precise NIST-traceable calibration in space the RBI sensor is designed to use a visible calibration target (VCT), a solar calibration target (SCT), and an infrared calibration target (ICT) containing phase change cells (PCC) to enable on-board temperature calibration. The VCT is a thermally controlled integrating sphere with space grade Spectralon covering the inner surface. Two sides of the sphere will have fiber-coupled laser diodes in the UV to IR wavelength region. An electrical substitution radiometer on the integrating sphere will monitor the long term stability of the sources and the possible degradation of the Spectralon in space. In addition the radiometric calibration operations will use the Spectralon diffusers of the SCT to provide accurate measurements of Solar degradation. All those stable on-orbit references will ensure that calibration stability is maintained over the RBI sensor lifetime. For the preflight calibration the RBI will view five calibration sources - two integrating spheres and three CrIS (Cross-track Infrared Sounder ) -like blackbodies whose outputs will be validated with NIST calibration approach. Thermopile are the selected detectors for the RBI. The sensor has a requirement to perform lunar calibration in addition to solar calibration in space in a way similar to CERES

  1. Local high precision 3D measurement based on line laser measuring instrument

    Science.gov (United States)

    Zhang, Renwei; Liu, Wei; Lu, Yongkang; Zhang, Yang; Ma, Jianwei; Jia, Zhenyuan

    2018-03-01

    In order to realize the precision machining and assembly of the parts, the geometrical dimensions of the surface of the local assembly surfaces need to be strictly guaranteed. In this paper, a local high-precision three-dimensional measurement method based on line laser measuring instrument is proposed to achieve a high degree of accuracy of the three-dimensional reconstruction of the surface. Aiming at the problem of two-dimensional line laser measuring instrument which lacks one-dimensional high-precision information, a local three-dimensional profile measuring system based on an accurate single-axis controller is proposed. First of all, a three-dimensional data compensation method based on spatial multi-angle line laser measuring instrument is proposed to achieve the high-precision measurement of the default axis. Through the pretreatment of the 3D point cloud information, the measurement points can be restored accurately. Finally, the target spherical surface is needed to make local three-dimensional scanning measurements for accuracy verification. The experimental results show that this scheme can get the local three-dimensional information of the target quickly and accurately, and achieves the purpose of gaining the information and compensating the error for laser scanner information, and improves the local measurement accuracy.

  2. Cognitive Success: Instrumental Justifications of Normative Systems of Reasoning

    Directory of Open Access Journals (Sweden)

    Gerhard eSchurz

    2014-07-01

    Full Text Available In the first part of the paper (sec. 1-4, I argue that Elqayam and Evan's (2011 distinction between normative and instrumental conceptions of cognitive rationality corresponds to deontological versus teleological accounts in meta-ethics. I suggest that Elqayam and Evans' distinction be replaced by the distinction between a-priori intuition-based versus a-posteriori success-based accounts of cognitive rationality. The value of cognitive success lies in its instrumental rationality for almost-all practical purposes. In the second part (sec. 5-7, I point out that the Elqayam and Evans's distinction between normative and instrumental rationality is coupled with a second distinction: between logically general versus locally adaptive accounts of rationality. I argue that these are two independent distinctions should be treated as independent dimensions. I also demonstrate that logically general systems of reasoning can be instrumentally justified. However, such systems can only be cognitively successful if they are paired with successful inductive reasoning, which is the area where the program of adaptive (ecological rationality emerged, because there are no generally optimal inductive reasoning methods. I argue that the practical necessity of reasoning under changing environments constitutes a dilemma for ecological rationality, which I attempt to solve a dual account of rationality.

  3. Cognitive success: instrumental justifications of normative systems of reasoning

    Science.gov (United States)

    Schurz, Gerhard

    2014-01-01

    In the first part of the paper (sec. 1–4), I argue that Elqayam and Evan's (2011) distinction between normative and instrumental conceptions of cognitive rationality corresponds to deontological vs. teleological accounts in meta-ethics. I suggest that Elqayam and Evans' distinction be replaced by the distinction between a-priori intuition-based vs. a-posteriori success-based accounts of cognitive rationality. The value of cognitive success lies in its instrumental rationality for almost-all practical purposes. In the second part (sec. 5–7), I point out that the Elqayam and Evans's distinction between normative and instrumental rationality is coupled with a second distinction: between logically general vs. locally adaptive accounts of rationality. I argue that these are two independent distinctions that should be treated as independent dimensions. I also demonstrate that logically general systems of reasoning can be instrumentally justified. However, such systems can only be cognitively successful if they are paired with successful inductive reasoning, which is the area where the program of adaptive (ecological) rationality emerged, because there are no generally optimal inductive reasoning methods. I argue that the practical necessity of reasoning under changing environments constitutes a dilemma for ecological rationality, which I attempt to solve within a dual account of rationality. PMID:25071624

  4. Fatigue behavior of lubricated Ni-Ti endodontic rotary instruments

    Directory of Open Access Journals (Sweden)

    A. Brotzu

    2014-04-01

    Full Text Available The use of Ni-Ti alloys in the practice of endodontic comes from their important properties such as shape memory and superelasticity phenomena, good corrosion resistance and high compatibility with biological tissues. In the last twenty years a great variety of nickel-titanium rotary instruments, with various sections and taper, have been developed and marketed. Although they have many advantages and despite their increasing popularity, a major concern with the use of Ni-Ti rotary instruments is the possibility of unexpected failure in use due to several reasons: novice operator handling, presence manufacturing defects, fatigue etc. Recently, the use of an aqueous gel during experimental tests showed a longer duration of the instruments. The aim of the present work is to contribute to the study of the fracture behavior of these endodontic rotary instruments particularly assessing whether the use of the aqueous lubricant gel can extend their operative life stating its reasons. A finite element model (FEM has been developed to support the experimental results. The results were rather contradictory, also because the Perspex (Poly-methyl methacrylate, PMMA cannot simulate completely the dentin mechanical behavior; however the results highlight some interesting points which are discussed in the paper.

  5. Student mathematical imagination instruments: construction, cultural adaptation and validity

    Science.gov (United States)

    Dwijayanti, I.; Budayasa, I. K.; Siswono, T. Y. E.

    2018-03-01

    Imagination has an important role as the center of sensorimotor activity of the students. The purpose of this research is to construct the instrument of students’ mathematical imagination in understanding concept of algebraic expression. The researcher performs validity using questionnaire and test technique and data analysis using descriptive method. Stages performed include: 1) the construction of the embodiment of the imagination; 2) determine the learning style questionnaire; 3) construct instruments; 4) translate to Indonesian as well as adaptation of learning style questionnaire content to student culture; 5) perform content validation. The results stated that the constructed instrument is valid by content validation and empirical validation so that it can be used with revisions. Content validation involves Indonesian linguists, english linguists and mathematics material experts. Empirical validation is done through a legibility test (10 students) and shows that in general the language used can be understood. In addition, a questionnaire test (86 students) was analyzed using a biserial point correlation technique resulting in 16 valid items with a reliability test using KR 20 with medium reability criteria. While the test instrument test (32 students) to find all items are valid and reliability test using KR 21 with reability is 0,62.

  6. Cognitive success: instrumental justifications of normative systems of reasoning.

    Science.gov (United States)

    Schurz, Gerhard

    2014-01-01

    In the first part of the paper (sec. 1-4), I argue that Elqayam and Evan's (2011) distinction between normative and instrumental conceptions of cognitive rationality corresponds to deontological vs. teleological accounts in meta-ethics. I suggest that Elqayam and Evans' distinction be replaced by the distinction between a-priori intuition-based vs. a-posteriori success-based accounts of cognitive rationality. The value of cognitive success lies in its instrumental rationality for almost-all practical purposes. In the second part (sec. 5-7), I point out that the Elqayam and Evans's distinction between normative and instrumental rationality is coupled with a second distinction: between logically general vs. locally adaptive accounts of rationality. I argue that these are two independent distinctions that should be treated as independent dimensions. I also demonstrate that logically general systems of reasoning can be instrumentally justified. However, such systems can only be cognitively successful if they are paired with successful inductive reasoning, which is the area where the program of adaptive (ecological) rationality emerged, because there are no generally optimal inductive reasoning methods. I argue that the practical necessity of reasoning under changing environments constitutes a dilemma for ecological rationality, which I attempt to solve within a dual account of rationality.

  7. Adaptation of instruments developed to study the effectiveness of psychotherapeutic processes

    Directory of Open Access Journals (Sweden)

    Shushanikova, Anastasia A.

    2016-06-01

    Full Text Available The objective of the research was to adapt for use in Russian-language contexts a set of instruments that assess the effectiveness of psychotherapeutic practices. The instruments explore the effectiveness of different types of therapy, without evaluating the abstract, idealized characteristics or specifics of each approach, specialist, or therapeutic case. The adapted instruments are based on reflective data about the significance of therapeutic events, from the point of view of both the client and the therapist. We translated, edited, and adapted forms developed by John McLeod and Mick Cooper — a “Goals Form”, a “Goal Assessment Form”, a “Post-Session Form”, and a “Therapy Personalization Form”. The adaption was intended to cohere with the stylistic and cultural aspects of the Russian language. The research showed that the instruments and the methods have great potential for practical and theoretical application in qualitative studies to formulate hypotheses and to verify them in quantitative studies. The phenomenological analysis reveals the reliability, appropriateness, and validity of the adapted instruments for identifying specific meanings of the psychotherapeutic cases considered. The instruments can be used in studies exploring helpful aspects and effectiveness in different types of therapy (cognitive, existential, outdoor therapy, online counseling, etc. with different groups of clients. It is reasonable to continue the use of the Russian-language version of the instruments in further studies exploring the effectiveness of psychological practices. The adapted instruments facilitate comparison and cross-cultural studies, and formulation of meaningful hypotheses about the effectiveness and quality of the psychotherapeutic process.

  8. Validation of mental health screening instruments in the Kashmir Valley, India.

    Science.gov (United States)

    Housen, Tambri; Lenglet, Annick; Ariti, Cono; Ara, Shabnum; Shah, Showkat; Dar, Maqbool; Hussain, Arshad; Paul, Altaf; Wagay, Zahoor; Viney, Kerri; Janes, Simon; Pintaldi, Giovanni

    2018-06-01

    The present study aimed to culturally adapt, translate, and validate the Hopkins Symptom Checklist-25 (HSCL-25) and the Harvard Trauma Questionnaire-Posttraumatic Stress Symptoms Checklist (HTQ-16) prior to use in a cross-sectional mental health population survey in the Kashmir Valley. Cultural adaptation and translation of the HSCL-25 and the HTQ-16 employed multiple forms of transcultural validity check. The HSCL-25 and HTQ-16 were compared against a "gold standard" structured psychiatric interview, the Mini International Neuropsychiatric Interview (MINI). Interviews were conducted with 290 respondents recruited using consecutive sampling from general medical outpatient departments in five districts of the Kashmir Valley. Receiver operating characteristics (ROC) analysis was used to estimate the cut point with optimal discriminatory power based on sensitivity and specificity. Internal reliability of the HSCL-25 was high, Cronbach's alpha (α) = .92, intraclass correlation coefficient (ICC) = 0.75, with an estimated optimal cut point of 1.50, lower than the conventional cut point of 1.75. Separation of the instruments into subscales demonstrated a difference in the estimated cut point for the anxiety subscale and the depression subscale, 1.75 and 1.57, respectively. Too few respondents were diagnosed with posttraumatic stress disorder (PTSD) during structured psychiatric interview, and therefore the HTQ-16 could not be validated despite the fact that high internal reliability was demonstrated (α = .90). This study verified the importance of culturally adapting and validating screening instruments in particular contexts. The use of the conventional cut point of 1.75 would likely have misclassified depression in our survey, leading to an underestimate of this condition.

  9. Comparability of Results between Point-of-Care and Automated Instruments to Measure B-type Natriuretic Peptide

    OpenAIRE

    Shah, Kevin; Terracciano, Garrett J.; Jiang, Kevin; Maisel, Alan S.; Fitzgerald, Robert L.

    2010-01-01

    Objectives: Heart failure is one of the leading causes of death in the U.S. The incorporation of B-type natriuretic peptide (BNP) measurements when triaging patients presenting with shortness of breath has improved the diagnostic and prognostic ability of physicians. Currently, there are no point-of-care systems for quantifying BNP that can be used without sacrificing accuracy. We compared the analytical performance of the Abbott i-STAT analyzer, a handheld point-of-care system for measuring ...

  10. Instrumentation for Reflectance Spectroscopy and Microspectroscopy with Application to Astrobiology

    Science.gov (United States)

    Mouroulis, Pantazis; Blaney, Diana L.; Green, Robert O.

    2008-01-01

    We present instrument concepts for in-situ reflectance spectroscopy over a spatial resolution range from several meters to tens of micrometers. These have been adapted to the low mass and power requirements of rover or similar platforms. Described are a miniaturized imaging spectrometer for rover mast, a combined mast and arm point spectrometer, and an imaging microspectrometer for the rover arm.

  11. Instrument performance evaluation

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1993-03-01

    Deficiencies exist in both the performance and the quality of health physics instruments. Recognizing the implications of such deficiencies for the protection of workers and the public, in the early 1980s the DOE and the NRC encouraged the development of a performance standard and established a program to test a series of instruments against criteria in the standard. The purpose of the testing was to establish the practicality of the criteria in the standard, to determine the performance of a cross section of available instruments, and to establish a testing capability. Over 100 instruments were tested, resulting in a practical standard and an understanding of the deficiencies in available instruments. In parallel with the instrument testing, a value-impact study clearly established the benefits of implementing a formal testing program. An ad hoc committee also met several times to establish recommendations for the voluntary implementation of a testing program based on the studies and the performance standard. For several reasons, a formal program did not materialize. Ongoing tests and studies have supported the development of specific instruments and have helped specific clients understand the performance of their instruments. The purpose of this presentation is to trace the history of instrument testing to date and suggest the benefits of a centralized formal program

  12. Verification of alternative dew point hygrometer for CV-LRT in MONJU. Short- and long-term verification of capacitance-type dew point hygrometer (Translated document)

    International Nuclear Information System (INIS)

    Ichikawa, Shoichi; Chiba, Yusuke; Ono, Fumiyasu; Hatori, Masakazu; Kobayashi, Takanori; Uekura, Ryoichi; Hashiri, Nobuo; Inuzuka, Taisuke; Kitano, Hiroshi; Abe, Hisashi

    2017-03-01

    To reduce the influence of maintenance of dew point hygrometers on the plant schedule at the prototype fast-breeder reactor MONJU, Japan Atomic Energy Agency examined a capacitance-type dew point hygrometer as an alternative to the lithium-chloride dew point hygrometer being used in the containment vessel leak rate test. As verifications, a capacitance-type dew point hygrometer was compared with a lithium-chloride dew point hygrometer under a containment vessel leak rate test condition. And the capacitance-type dew point hygrometer was compared with a high-precision-mirror-surface dew point hygrometer for long-term (2 years) in the containment vessel as an unprecedented try. A comparison of a capacitance-type dew point hygrometer with a lithium-chloride dew point hygrometer in a containment vessel leak rate test (Atmosphere: nitrogen, Testing time: 24 h) revealed no significant difference between the capacitance-type dew point hygrometer and the lithium-chloride dew point hygrometer. A comparison of the capacitance-type dew point hygrometer with the high-precision-mirror-surface dew point hygrometer for long-term verification (Atmosphere: air, Testing time: 24 months) revealed that the capacitance-type dew point hygrometer satisfied the instrumental specification (synthesized precision of detector and converter: ±2.04°C) specified in the Leak Rate Test Regulations for Nuclear Reactor Containment Vessel. It was confirmed that the capacitance-type dew point hygrometer can be used as a long-term alternative to the lithium-chloride dew point hygrometer without affecting the dew point hygrometer maintenance schedule of the MONJU plant. (author)

  13. PECULIARITIES OF PROGRAMME MUSIC IN THE INSTRUMENTAL SUITE OF COMPOSERS FROM THE REPUBLIC OF MOLDOVA

    Directory of Open Access Journals (Sweden)

    BEREZOVICOVA TATIANA

    2015-09-01

    Full Text Available The article is dedicated to the study of the instrumental suites written by native composers from the point of view of the realization of programme music. The author analyses different kinds of programme music such as genre, stylistic, pictorial (without any subject, with a generalized subject, with a concrete subject, as well as latent programme music, felt in some non-programme compositions declared and expressed through specific instrumental means.

  14. The OCO-3 Mission: Science Objectives and Instrument Performance

    Science.gov (United States)

    Eldering, A.; Basilio, R. R.; Bennett, M. W.

    2017-12-01

    The Orbiting Carbon Observatory 3 (OCO-3) will continue global CO2 and solar-induced chlorophyll fluorescence (SIF) using the flight spare instrument from OCO-2. The instrument is currently being tested, and will be packaged for installation on the International Space Station (ISS) (launch readiness in early 2018.) This talk will focus on the science objectives, updated simulations of the science data products, and the outcome of recent instrument performance tests. The low-inclination ISS orbit lets OCO-3 sample the tropics and sub-tropics across the full range of daylight hours with dense observations at northern and southern mid-latitudes (+/- 52º). The combination of these dense CO2 and SIF measurements provides continuity of data for global flux estimates as well as a unique opportunity to address key deficiencies in our understanding of the global carbon cycle. The instrument utilizes an agile, 2-axis pointing mechanism (PMA), providing the capability to look towards the bright reflection from the ocean and validation targets. The PMA also allows for a snapshot mapping mode to collect dense datasets over 100km by 100km areas. Measurements over urban centers could aid in making estimates of fossil fuel CO2 emissions. Similarly, the snapshot mapping mode can be used to sample regions of interest for the terrestrial carbon cycle. In addition, there is potential to utilize data from ISS instruments ECOSTRESS (ECOsystem Spaceborne Thermal Radiometer Experiment on Space Station) and GEDI (Global Ecosystem Dynamics Investigation), which measure other key variables of the control of carbon uptake by plants, to complement OCO-3 data in science analysis. In 2017, the OCO-2 instrument was transformed into the ISS-ready OCO-3 payload. The transformed instrument was thoroughly tested and characterized. Key characteristics, such as instrument ILS, spectral resolution, and radiometric performance will be described. Analysis of direct sun measurements taken during testing

  15. Teen drivers' awareness of vehicle instrumentation in naturalistic research.

    Science.gov (United States)

    Ehsani, J P; Haynie, D; Ouimet, M C; Zhu, C; Guillaume, C; Klauer, S G; Dingus, T; Simons-Morton, B G

    2017-12-01

    Naturalistic driving methods require the installation of instruments and cameras in vehicles to record driving behavior. A critical, yet unexamined issue in naturalistic driving research is the extent to which the vehicle instruments and cameras used for naturalistic methods change human behavior. We sought to describe the degree to which teenage participants' self-reported awareness of vehicle instrumentation changes over time, and whether that awareness was associated with driving behaviors. Forty-two newly-licensed teenage drivers participated in an 18-month naturalistic driving study. Data on driving behaviors including crash/near-crashes and elevated gravitational force (g-force) events rates were collected over the study period. At the end of the study, participants were asked to rate the extent to which they were aware of instruments in the vehicle at four time points. They were also asked to describe their own and their passengers' perceptions of the instrumentation in the vehicle during an in-depth interview. The number of critical event button presses was used as a secondary measure of camera awareness. The association between self-reported awareness of the instrumentation and objectively measured driving behaviors was tested using correlations and linear mixed models. Most participants' reported that their awareness of vehicle instrumentation declined across the duration of the 18-month study. Their awareness increased in response to their passengers' concerns about the cameras or if they were involved in a crash. The number of the critical event button presses was initially high and declined rapidly. There was no correlation between driver's awareness of instrumentation and their crash and near-crash rate or elevated g-force events rate. Awareness was not associated with crash and near-crash rates or elevated g-force event rates, consistent with having no effect on this measure of driving performance. Naturalistic driving studies are likely to yield

  16. Sprint performance and propulsion asymmetries on an ergometer in trained high- and low-point wheelchair rugby players

    NARCIS (Netherlands)

    Goosey-Tolfrey, Victoria L; Vegter, Riemer J K; Mason, Barry S; Paulson, Thomas A W; Lenton, John P; van der Scheer, Jan W; van der Woude, Lucas H V

    The purpose of this study was to examine the propulsion asymmetries of wheelchair athletes while sprinting on an instrumented, dual-roller ergometer system. Eighteen experienced wheelchair rugby players (8 low point (LP) (class 1.5) and 10 high point (HP) (class 2.0)) performed a 15-second sprint in

  17. Atmospheric, Magnetospheric, and Plasmas in Space (AMPS) spacelab payload definition study, appendixes

    Science.gov (United States)

    Keeley, J. T.

    1976-01-01

    An equipment list, instrument baseline data, engineering drawings, mass properties computer printouts, electrical energy management, and control and display functional analysis pertinent to the AMPS (Satellite Payload) are presented.

  18. The Neurolab mission and biomedical engineering: a partnership for the future

    Science.gov (United States)

    Liskowsky, D. R.; Frey, M. A.; Sulzman, F. M.; White, R. J.; Likowsky, D. R.

    1996-01-01

    Over the last five years, with the advent of flights of U.S. Shuttle/Spacelab missions dedicated entirely to life sciences research, the opportunities for conducting serious studies that use a fully outfitted space laboratory to better understand basic biological processes have increased. The last of this series of Shuttle/Spacelab missions, currently scheduled for 1998, is dedicated entirely to neuroscience and behavioral research. The mission, named Neurolab, includes a broad range of experiments that build on previous research efforts, as well as studies related to less mature areas of space neuroscience. The Neurolab mission provides the global scientific community with the opportunity to use the space environment for investigations that exploit microgravity to increase our understanding of basic processes in neuroscience. The results from this premier mission should lead to a significant advancement in the field as a whole and to the opening of new lines of investigation for future research. Experiments under development for this mission will utilize human subjects as well as a variety of other species. The capacity to carry out detailed experiments on both human and animal subjects in space allows a diverse complement of studies that investigate functional changes and their underlying molecular, cellular, and physiological mechanisms. In order to conduct these experiments, a wide array of biomedical instrumentation will be used, including some instruments and devices being developed especially for the mission.

  19. Key issues in the thermal design of spaceborne cryogenic infrared instruments

    Science.gov (United States)

    Schember, Helene R.; Rapp, Donald

    1992-12-01

    Thermal design and analysis play an integral role in the development of spaceborne cryogenic infrared (IR) instruments. From conceptual sketches to final testing, both direct and derived thermal requirements place significant constraints on the instrument design. Although in practice these thermal requirements are interdependent, the sources of most thermal constraints may be grouped into six distinct categories. These are: (1) Detector temperatures, (2) Optics temperatures, (3) Pointing or alignment stability, (4) Mission lifetime, (5) Orbit, and (6) Test and Integration. In this paper, we discuss these six sources of thermal requirements with particular regard to development of instrument packages for low background infrared astronomical observatories. In the end, the thermal performance of these instruments must meet a set of thermal requirements. The development of these requirements is typically an ongoing and interactive process, however, and the thermal design must maintain flexibility and robustness throughout the process. The thermal (or cryogenic) engineer must understand the constraints imposed by the science requirements, the specific hardware, the observing environment, the mission design, and the testing program. By balancing these often competing factors, the system-oriented thermal engineer can work together with the experiment team to produce an effective overall design of the instrument.

  20. The development and validation of the speech quality instrument.

    Science.gov (United States)

    Chen, Stephanie Y; Griffin, Brianna M; Mancuso, Dean; Shiau, Stephanie; DiMattia, Michelle; Cellum, Ilana; Harvey Boyd, Kelly; Prevoteau, Charlotte; Kohlberg, Gavriel D; Spitzer, Jaclyn B; Lalwani, Anil K

    2017-12-08

    Although speech perception tests are available to evaluate hearing, there is no standardized validated tool to quantify speech quality. The objective of this study is to develop a validated tool to measure quality of speech heard. Prospective instrument validation study of 35 normal hearing adults recruited at a tertiary referral center. Participants listened to 44 speech clips of male/female voices reciting the Rainbow Passage. Speech clips included original and manipulated excerpts capturing goal qualities such as mechanical and garbled. Listeners rated clips on a 10-point visual analog scale (VAS) of 18 characteristics (e.g. cartoonish, garbled). Skewed distribution analysis identified mean ratings in the upper and lower 2-point limits of the VAS (ratings of 8-10, 0-2, respectively); items with inconsistent responses were eliminated. The test was pruned to a final instrument of nine speech clips that clearly define qualities of interest: speech-like, male/female, cartoonish, echo-y, garbled, tinny, mechanical, rough, breathy, soothing, hoarse, like, pleasant, natural. Mean ratings were highest for original female clips (8.8) and lowest for not-speech manipulation (2.1). Factor analysis identified two subsets of characteristics: internal consistency demonstrated Cronbach's alpha of 0.95 and 0.82 per subset. Test-retest reliability of total scores was high, with an intraclass correlation coefficient of 0.76. The Speech Quality Instrument (SQI) is a concise, valid tool for assessing speech quality as an indicator for hearing performance. SQI may be a valuable outcome measure for cochlear implant recipients who, despite achieving excellent speech perception, often experience poor speech quality. 2b. Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  1. The 5th questionnaire report of safety control on instrument in nuclear medicine laboratory

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    The questionnaire was done every three years from 1986 for the ultimate purpose of safe medical examinations and this 5th one was performed in May, 1998 for the period of April, 1995-March, 1998. Subjects were 1,258 nuclear medicine facilities and answers were obtained in 81.6%. Questionnaire concerned the personnel involved in nuclear medical examinations, instruments, accidents occurred, matters possibly leading to accident, improvement in safety control, serious trouble and breakage of the instrument, request for the instrument manufacturers and so on. Summaries were: numbers of medical radiology technicians were increased, in vitro tests were decreased, SPECT instruments came into wide use, in accident and improvement cases, examination beds were arousing much interest, concerns to examine were further required, communication with the manufacturers was insufficient, and problems for Y2K were pointed out to be resolved. (K.H.)

  2. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  3. Pitch Fork: A Novel tactile Digital Musical Instrument

    OpenAIRE

    Williams, Peter; Overholt, Daniel

    2017-01-01

    Pitch Fork is a prototype of an alternate, actuated digital musical instrument (DMI). It uses 5 infra-red and 4 piezoelectric sensors to control an additive synthesis engine. Iron bars are used as the physical point of contact in interaction with the aim of using material computation to control aspects of the digitally produced sound. This choice of material was also chosen to affect player experience. Sensor readings are relayed to a Macbook via an Arduino Mega. Mappings and audio output sig...

  4. Performing the Super Instrument

    DEFF Research Database (Denmark)

    Kallionpaa, Maria

    2016-01-01

    can empower performers by producing super instrument works that allow the concert instrument to become an ensemble controlled by a single player. The existing instrumental skills of the performer can be multiplied and the qualities of regular acoustic instruments extended or modified. Such a situation......The genre of contemporary classical music has seen significant innovation and research related to new super, hyper, and hybrid instruments, which opens up a vast palette of expressive potential. An increasing number of composers, performers, instrument designers, engineers, and computer programmers...... have become interested in different ways of “supersizing” acoustic instruments in order to open up previously-unheard instrumental sounds. Super instruments vary a great deal but each has a transformative effect on the identity and performance practice of the performing musician. Furthermore, composers...

  5. Study into Point Cloud Geometric Rigidity and Accuracy of TLS-Based Identification of Geometric Bodies

    Science.gov (United States)

    Klapa, Przemyslaw; Mitka, Bartosz; Zygmunt, Mariusz

    2017-12-01

    Capability of obtaining a multimillion point cloud in a very short time has made the Terrestrial Laser Scanning (TLS) a widely used tool in many fields of science and technology. The TLS accuracy matches traditional devices used in land surveying (tacheometry, GNSS - RTK), but like any measurement it is burdened with error which affects the precise identification of objects based on their image in the form of a point cloud. The point’s coordinates are determined indirectly by means of measuring the angles and calculating the time of travel of the electromagnetic wave. Each such component has a measurement error which is translated into the final result. The XYZ coordinates of a measuring point are determined with some uncertainty and the very accuracy of determining these coordinates is reduced as the distance to the instrument increases. The paper presents the results of examination of geometrical stability of a point cloud obtained by means terrestrial laser scanner and accuracy evaluation of solids determined using the cloud. Leica P40 scanner and two different settings of measuring points were used in the tests. The first concept involved placing a few balls in the field and then scanning them from various sides at similar distances. The second part of measurement involved placing balls and scanning them a few times from one side but at varying distances from the instrument to the object. Each measurement encompassed a scan of the object with automatic determination of its position and geometry. The desk studies involved a semiautomatic fitting of solids and measurement of their geometrical elements, and comparison of parameters that determine their geometry and location in space. The differences of measures of geometrical elements of balls and translations vectors of the solids centres indicate the geometrical changes of the point cloud depending on the scanning distance and parameters. The results indicate the changes in the geometry of scanned objects

  6. Precise pointing knowledge for SCIAMACHY solar occultation measurements

    Directory of Open Access Journals (Sweden)

    K. Bramstedt

    2012-11-01

    Full Text Available We present a method to precisely determine the viewing direction for solar occultation instruments from scans over the solar disk. Basic idea is the fit of the maximum intensity during the scan, which corresponds to the center of the solar disk in the scanning direction. We apply this method to the solar occultation measurements of the satellite instrument SCIAMACHY, which scans the Sun in elevation direction. The achieved mean precision is 0.46 mdeg, which corresponds to an tangent height error of about 26 m for individual occultation sequences. The deviation of the derived elevation angle from the geolocation information given along with the product has a seasonal cycle with an amplitude of 2.26 mdeg, which is in tangent height an amplitude of about 127 m. The mean elevation angle offset is −4.41 mdeg (249 m. SCIAMACHY's sun follower device controls the azimuth viewing direction during the occultation measurements. The derived mean azimuth direction has an standard error of 0.65 mdeg, which is about 36 m in horizontal direction at the tangent point. We observe also a seasonal cycle of the azimuth mispointing with an amplitude of 2.3 mdeg, which is slightly increasing with time. The almost constant mean offset is 88 mdeg, which is about 5.0 km horizontal offset at the tangent point.

  7. Testing instrument validity for LATE identification based on inequality moment constraints

    DEFF Research Database (Denmark)

    Huber, Martin; Mellace, Giovanni

    2015-01-01

    We derive testable implications of instrument validity in just identified treatment effect models with endogeneity and consider several tests. The identifying assumptions of the local average treatment effect allow us to both point identify and bound the mean potential outcomes (i) of the always...... takers under treatment and (ii) of the never takers under non-treatment. The point identified means must lie within their respective bounds, which provides us with four testable inequality moment constraints. Finally, we adapt our testing framework to the identification of distributional features....... A brief simulation study and an application to labor market data are also provided....

  8. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  9. VIRUS instrument enclosures

    Science.gov (United States)

    Prochaska, T.; Allen, R.; Mondrik, N.; Rheault, J. P.; Sauseda, M.; Boster, E.; James, M.; Rodriguez-Patino, M.; Torres, G.; Ham, J.; Cook, E.; Baker, D.; DePoy, Darren L.; Marshall, Jennifer L.; Hill, G. J.; Perry, D.; Savage, R. D.; Good, J. M.; Vattiat, Brian L.

    2014-08-01

    The Visible Integral-Field Replicable Unit Spectrograph (VIRUS) instrument will be installed at the Hobby-Eberly Telescope† in the near future. The instrument will be housed in two enclosures that are mounted adjacent to the telescope, via the VIRUS Support Structure (VSS). We have designed the enclosures to support and protect the instrument, to enable servicing of the instrument, and to cool the instrument appropriately while not adversely affecting the dome environment. The system uses simple HVAC air handling techniques in conjunction with thermoelectric and standard glycol heat exchangers to provide efficient heat removal. The enclosures also provide power and data transfer to and from each VIRUS unit, liquid nitrogen cooling to the detectors, and environmental monitoring of the instrument and dome environments. In this paper, we describe the design and fabrication of the VIRUS enclosures and their subsystems.

  10. Health physics instrument manual

    International Nuclear Information System (INIS)

    Gupton, E.D.

    1978-08-01

    The purpose of this manual is to provide apprentice health physics surveyors and other operating groups not directly concerned with radiation detection instruments a working knowledge of the radiation detection and measuring instruments in use at the Laboratory. The characteristics and applications of the instruments are given. Portable instruments, stationary instruments, personnel monitoring instruments, sample counters, and miscellaneous instruments are described. Also, information sheets on calibration sources, procedures, and devices are included. Gamma sources, beta sources, alpha sources, neutron sources, special sources, a gamma calibration device for badge dosimeters, and a calibration device for ionization chambers are described

  11. Number crunchers : instrumentation sector treads path of selective automation

    International Nuclear Information System (INIS)

    Budd, G.

    2006-01-01

    Automation guided by adequate monitoring and control instrumentation is playing an increasingly important role in the oil and gas sector. This article presented a overview of new instruments in the Western Canada Sedimentary Basin (WCSB), where a niche market for instrumentation and automation has grown in tandem with increased drilling activities. Fluctuating prices in oil and gas have also meant that available production methods must be optimized in order to ensure bottom line profits. However, economies of production scale can exclude extensive monitoring techniques in coalbed methane (CBM) activities. Compressor stations are the site of most monitoring and control instrumentation in CBM activities. Compressor packages at the stations include an engine panel that monitors suction pressure and water temperature. Alarm points on all monitoring instrumentation can shut down operations or assist in slight adjustments to machinery to optimize production. In addition, acoustical flow meters are fitted to headers to identify drops in a station's overall volumetric flow of natural gas. Instrumentation at the stations monitors and controls boilers that heat glycol for the gas dehydration process through the use of a pneumatic control loop that communicates with the motor control centre. The system is capable of ensuring shut-downs in emergencies. The combination of automation and carbon dioxide (CO 2 ) flooding has dramatically improved production in the Weyburn oilfield in southeastern Saskatchewan, where data transfer is now completed using Ethernet communications to a SCADA system to communicate with and from 5 satellite sites to a central main plant. It was estimated that the life expectancy of the Weyburn oilfield has been extended by almost 25 years. It was concluded that when harnessed to other technologies and combined with a user-friendly interface, automation can make a huge difference in the production profile of a field. 2 figs

  12. The ViewPoint radioprotection supervision workstation; Poste de supervision radioprotection viewpoint

    Energy Technology Data Exchange (ETDEWEB)

    Gaultier, E. [APVL Ingenierie- 6, bd Nobel - Equatop La Rabelais - 37540 Saint Cyr sur Loire (France)

    2009-07-01

    The author briefly presents the ViewPoint supervision global solution which incorporates audio and video advanced technologies to manage radioprotection operational measurements. Data can be transmitted by-wire or wireless. It can integrate a large number of radioprotection measurement instruments, such as a belt for the monitoring of physiological parameters (body temperature, breathing rhythm, body posture)

  13. Nuclear reactor instrumentation

    International Nuclear Information System (INIS)

    Duncombe, E.; McGonigal, G.

    1975-01-01

    A liquid metal cooled nuclear reactor is described which has an equal number of fuel sub-assemblies and sensing instruments. Each instrument senses temperature and rate of coolant flow of a coolant derived from a group of three sub-assemblies so that an abnormal value for one sub-assembly will be indicated on three instruments thereby providing for redundancy of up to two of the three instruments. The abnormal value may be a precurser to unstable boiling of coolant

  14. Social interactions and college enrollment: A combined school fixed effects/instrumental variables approach.

    Science.gov (United States)

    Fletcher, Jason M

    2015-07-01

    This paper provides some of the first evidence of peer effects in college enrollment decisions. There are several empirical challenges in assessing the influences of peers in this context, including the endogeneity of high school, shared group-level unobservables, and identifying policy-relevant parameters of social interactions models. This paper addresses these issues by using an instrumental variables/fixed effects approach that compares students in the same school but different grade-levels who are thus exposed to different sets of classmates. In particular, plausibly exogenous variation in peers' parents' college expectations are used as an instrument for peers' college choices. Preferred specifications indicate that increasing a student's exposure to college-going peers by ten percentage points is predicted to raise the student's probability of enrolling in college by 4 percentage points. This effect is roughly half the magnitude of growing up in a household with married parents (vs. an unmarried household). Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Safeguarding on-power fuelled reactors - instrumentation and techniques

    International Nuclear Information System (INIS)

    Waligura, A.; Konnov, Y.; Smith, R.M.; Head, D.A.

    1977-01-01

    Instrumentation and techniques applicable to safeguarding reactors that are fuelled on-power, particularly the CANDU type, have been developed. A demonstration is being carried out at the Douglas Point Nuclear Generating Station in Canada. Irradiated nuclear materials in certain areas - the reactor and spent fuel storage bays - are monitored using photographic and television cameras, and seals. Item accounting is applied by counting spent-fuel bundles during transfer from the reactor to the storage bay and by placing these spent-fuel bundles in a sealed enclosure. Provision is made for inspection and verification of the bundles before sealing. The reactor's power history is recorded by a track-etch power monitor. Redundancy is provided so that the failure of any single piece of equipment does not invalidate the entire safeguards system. Several safeguards instruments and devices have beeen developed and evaluated. These include a super-8 mm surveillance camera system, a television surveillance system, a spent-fuel bundle counter, a device to detect dummy fuel bundles, a cover for enclosing a stack of spent-fuel bundles, and a seal suitable for underwater installation and ultrasonic interrogation. The information provided by these different instruments should increase the effectiveness of Agency safeguards and, when used in combination with other measures, will facilitate inspection at reactor sites

  16. Instrument validation project

    International Nuclear Information System (INIS)

    Reynolds, B.A.; Daymo, E.A.; Geeting, J.G.H.; Zhang, J.

    1996-06-01

    Westinghouse Hanford Company Project W-211 is responsible for providing the system capabilities to remove radioactive waste from ten double-shell tanks used to store radioactive wastes on the Hanford Site in Richland, Washington. The project is also responsible for measuring tank waste slurry properties prior to injection into pipeline systems, including the Replacement of Cross-Site Transfer System. This report summarizes studies of the appropriateness of the instrumentation specified for use in Project W-211. The instruments were evaluated in a test loop with simulated slurries that covered the range of properties specified in the functional design criteria. The results of the study indicate that the compact nature of the baseline Project W-211 loop does not result in reduced instrumental accuracy resulting from poor flow profile development. Of the baseline instrumentation, the Micromotion densimeter, the Moore Industries thermocouple, the Fischer and Porter magnetic flow meter, and the Red Valve Pressure transducer meet the desired instrumental accuracy. An alternate magnetic flow meter (Yokagawa) gave nearly identical results as the baseline fischer and Porter. The Micromotion flow meter did not meet the desired instrument accuracy but could potentially be calibrated so that it would meet the criteria. The Nametre on-line viscometer did not meet the desired instrumental accuracy and is not recommended as a quantitative instrument although it does provide qualitative information. The recommended minimum set of instrumentation necessary to ensure the slurry meets the Project W-058 acceptance criteria is the Micromotion mass flow meter and delta pressure cells

  17. The Mercury Laser Altimeter Instrument for the MESSENGER Mission

    Science.gov (United States)

    Cavanaugh, John F.; Smith, James C.; Sun, Xiaoli; Bartels, Arlin E.; Ramos-Izquierdo, Luis; Krebs, Danny J.; Novo-Gradac, Anne marie; McGarry, Jan F.; Trunzo, Raymond; Britt, Jamie L.

    2006-01-01

    The Mercury Laser Altimeter (MLA) is one of the payload science instruments on the MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) mission, which launched on 3 August 2004. The altimeter will measure the round trip time-of-flight of transmitted laser pulses reflected from the surface of the planet that, in combination with the spacecraft orbit position and pointing data, gives a high-precision measurement of surface topography referenced to Mercury's center of mass. The altimeter measurements will be used to determine the planet's forced librations by tracking the motion of large-scale topographic features as a function of time. MLA's laser pulse energy monitor and the echo pulse energy estimate will provide an active measurement of the surface reflectivity at 1064 nm. This paper describes the instrument design, prelaunch testing, calibration, and results of post-launch testing.

  18. Specification of requirements for upgrades using digital instrument and control systems. Report prepared within the framework of the international working group on nuclear power plant control and instrumentation

    International Nuclear Information System (INIS)

    1999-01-01

    The need to develop good specifications of requirements for instrument and control (I and C) systems applies throughout the world and is becoming more and more important as more upgrades are planned. Better guidance on how to develop good requirements specifications would support safer, more effective and more economical refits and upgrades. The need for this was pointed out by the IAEA International Working Group on Nuclear Power Plant Control and Instrumentation (IWG-NPPCI). This report is the result of a series of advisory and consultants meetings held by the IAEA in 1997 and 1998 in Vienna. The scope of the activities described covers a methodology for the determination of requirements and the development of the necessary specifications and plans needed through the life-cycle of digital instrumentation and control systems. It is restricted to technical aspects and indicates subjects which should be included in specifications and plans at different phases

  19. A REPERTOIRE OF INSTRUMENTS EMPLOYED IN PSYCHOLOGICAL COUNSELING

    Directory of Open Access Journals (Sweden)

    Dorina Maria PASCA

    2014-10-01

    Full Text Available According to Carl Rogers and Albert Ellis [1] [2], a new approach to psychological counseling is needed. Consequently, new and practical means to solve problems that ensue as part of the counseling process are required. From this point of view, this article aims at offering a range of alternatives to approach and involve the client (student in order to achieve the envisaged results of counseling. As such, it offers a concise repertoire of instruments that can be employed in psychological counseling.

  20. Astronomical Instruments in India

    Science.gov (United States)

    Sarma, Sreeramula Rajeswara

    The earliest astronomical instruments used in India were the gnomon and the water clock. In the early seventh century, Brahmagupta described ten types of instruments, which were adopted by all subsequent writers with minor modifications. Contact with Islamic astronomy in the second millennium AD led to a radical change. Sanskrit texts began to lay emphasis on the importance of observational instruments. Exclusive texts on instruments were composed. Islamic instruments like the astrolabe were adopted and some new types of instruments were developed. Production and use of these traditional instruments continued, along with the cultivation of traditional astronomy, up to the end of the nineteenth century.

  1. Design and development of an instrument to measure radiative absorption of seawater. Sumarad

    International Nuclear Information System (INIS)

    Fasano, G.; Materassi, A.

    2003-01-01

    In the present work, a low-cost instrument is presented that provides the ratio between underwater radiation and radiation outside water for the four spectral ranges fundamental for photosynthetic activity (Sub Marine Radiometer). The instrument essentially consists of two radiometers which operate in the same four bands: one acquires radiation outside the water, the other underwater radiation at a pre-established depth. The two acquisition systems are synchronized when the instrument is turned on and then, in the course of data elaboration, the ratio is obtained between underwater and outside water radiation for each spectral band, at any determined moment, at a predetermined depth. This ratio, in accordance with the Beer-Lambert equation, represents the transmittance of the medium crossed by radiation. By applying the Linke equation to collected data, it is also possible to determine the turbidity of the considered medium. The system can acquire as many as 1,472 data, with programmable temporal scanning, and can operate at depths up to 50 meters. Applications of this instrument are already in progress in studies concerning the relationship between solar radiation and photosynthetic activity of Posidonia oceanica. The proposed instrument has a relatively low cost, when compared with that of other instruments currently on the market, making it particularly suitable for applications that require numerous instruments to monitor sea, lacustrine or fluvial water in various points at the same time [it

  2. Defect propagation in NiTi rotary instruments: a noncontact optical profilometry analysis.

    Science.gov (United States)

    Barbosa, I; Ferreira, F; Scelza, P; Neff, J; Russano, D; Montagnana, M; Zaccaro Scelza, M

    2018-04-10

    To evaluate the presence and propagation of defects and their effects on surfaces of nickel-titanium (NiTi) instruments using noncontact, three-dimensional optical profilometry, and to assess the accuracy of this method of investigation. The flute surface areas of instruments from two commercial instrumentation systems, namely Reciproc R25 (n = 5) and WaveOne Primary (n = 5), were assessed and compared before and after performing two instrumentation cycles in simulated root canals in clear resin blocks. All the analyses were conducted on areas measuring 211 × 211 μm, located 3 mm from the tips of the instruments. A quantitative analysis was conducted before and after the first and second instrumentation cycles, using the Sa (average roughness over the measurement field), Sq (root mean square roughness) and Sz (average height over the measurement field) amplitude parameters. All the data were submitted to statistical analysis at a 5% level of significance. There was a significant increase (P = 0.007) in wear in both groups, especially between baseline and the second instrumentation cycle, with significantly higher wear values being observed on WaveOne instruments (Sz median values = 33.68 and 2.89 μm, respectively, for WO and RP groups). A significant increase in surface roughness (P = 0.016 and P = 0.008, respectively, for Sa and Sq) was observed in both groups from the first to the second instrumentation cycle, mostly in WaveOne specimens. Qualitative analysis revealed a greater number of defects on the flute topography of all the instruments after use. More defects were identified in WaveOne Primary instruments compared to Reciproc R25, irrespective of the evaluation stage. The investigation method provided an accurate, repeatable and reproducible assessment of NiTi instruments at different time-points. © 2018 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  3. Design of analytical instrumentation with D-T sealed neutron generators

    International Nuclear Information System (INIS)

    Qiao Yahua; Wu Jizong; Zheng Weiming; Liu Quanwei; Zhang Min

    2008-01-01

    Analytical instrumentation with D-T sealed neutron generators source activation, The 14 MeV D-T sealed neutron tube with 10 9 n · s -1 neutron yield is used as generator source. The optimal structure of moderator and shield was achieved by MC computing.The instrumentation's configuration is showed. The instrumentation is made up of the SMY-DT50.8-2.1 sealed neutron tube and the high-voltage power supply system, which center is the sealed neutron generators. 6 cm Pb and 20 cm polythene is chosen as moderator, Pb, polythene and 10 cm boron-PE was chosen as shield .The sample box is far the source from 9 cm, the measurement system were made up of HPGe detector and the sample transforming system. After moderator and shield, the thermal neutron fluence rate at the point of sample is 0.93 × 10 6 n · s -1 cm -2 , which is accorded with design demand, and the laboratory and surroundings reaches the safety standard of the dose levels. (authors)

  4. Wavefront-Error Performance Characterization for the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) Science Instruments

    Science.gov (United States)

    Aronstein, David L.; Smith, J. Scott; Zielinski, Thomas P.; Telfer, Randal; Tournois, Severine C.; Moore, Dustin B.; Fienup, James R.

    2016-01-01

    The science instruments (SIs) comprising the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) were tested in three cryogenic-vacuum test campaigns in the NASA Goddard Space Flight Center (GSFC)'s Space Environment Simulator (SES). In this paper, we describe the results of optical wavefront-error performance characterization of the SIs. The wavefront error is determined using image-based wavefront sensing (also known as phase retrieval), and the primary data used by this process are focus sweeps, a series of images recorded by the instrument under test in its as-used configuration, in which the focal plane is systematically changed from one image to the next. High-precision determination of the wavefront error also requires several sources of secondary data, including 1) spectrum, apodization, and wavefront-error characterization of the optical ground-support equipment (OGSE) illumination module, called the OTE Simulator (OSIM), 2) plate scale measurements made using a Pseudo-Nonredundant Mask (PNRM), and 3) pupil geometry predictions as a function of SI and field point, which are complicated because of a tricontagon-shaped outer perimeter and small holes that appear in the exit pupil due to the way that different light sources are injected into the optical path by the OGSE. One set of wavefront-error tests, for the coronagraphic channel of the Near-Infrared Camera (NIRCam) Longwave instruments, was performed using data from transverse translation diversity sweeps instead of focus sweeps, in which a sub-aperture is translated andor rotated across the exit pupil of the system.Several optical-performance requirements that were verified during this ISIM-level testing are levied on the uncertainties of various wavefront-error-related quantities rather than on the wavefront errors themselves. This paper also describes the methodology, based on Monte Carlo simulations of the wavefront-sensing analysis of focus-sweep data, used to establish the

  5. Suborbital Reusable Launch Vehicles as an Opportunity to Consolidate and Calibrate Ground Based and Satellite Instruments

    Science.gov (United States)

    Papadopoulos, K.

    2014-12-01

    XCOR Aerospace, a commercial space company, is planning to provide frequent, low cost access to near-Earth space on the Lynx suborbital Reusable Launch Vehicle (sRLV). Measurements in the external vacuum environment can be made and can launch from most runways on a limited lead time. Lynx can operate as a platform to perform suborbital in situ measurements and remote sensing to supplement models and simulations with new data points. These measurements can serve as a quantitative link to existing instruments and be used as a basis to calibrate detectors on spacecraft. Easier access to suborbital data can improve the longevity and cohesiveness of spacecraft and ground-based resources. A study of how these measurements can be made on Lynx sRLV will be presented. At the boundary between terrestrial and space weather, measurements from instruments on Lynx can help develop algorithms to optimize the consolidation of ground and satellite based data as well as assimilate global models with new data points. For example, current tides and the equatorial electrojet, essential to understanding the Thermosphere-Ionosphere system, can be measured in situ frequently and on short notice. Furthermore, a negative-ion spectrometer and a Faraday cup, can take measurements of the D-region ion composition. A differential GPS receiver can infer the spatial gradient of ionospheric electron density. Instruments and optics on spacecraft degrade over time, leading to calibration drift. Lynx can be a cost effective platform for deploying a reference instrument to calibrate satellites with a frequent and fast turnaround and a successful return of the instrument. A calibrated reference instrument on Lynx can make collocated observations as another instrument and corrections are made for the latter, thus ensuring data consistency and mission longevity. Aboard a sRLV, atmospheric conditions that distort remotely sensed data (ground and spacecraft based) can be measured in situ. Moreover, an

  6. Instrumentation a reader

    CERN Document Server

    Pope, P

    1990-01-01

    This book contains a selection of papers and articles in instrumentation previously pub­ lished in technical periodicals and journals of learned societies. Our selection has been made to illustrate aspects of current practice and applications of instrumentation. The book does not attempt to be encyclopaedic in its coverage of the subject, but to provide some examples of general transduction techniques, of the sensing of particular measurands, of components of instrumentation systems and of instrumentation practice in two very different environments, the food industry and the nuclear power industry. We have made the selection particularly to provide papers appropriate to the study of the Open University course T292 Instrumentation. The papers have been chosen so that the book covers a wide spectrum of instrumentation techniques. Because of this, the book should be of value not only to students of instrumen­ tation, but also to practising engineers and scientists wishing to glean ideas from areas of instrumen...

  7. Mechanical Description of the Mars Climate Sounder Instrument

    Science.gov (United States)

    Jau, Bruno M.

    2008-01-01

    This paper introduces the Mars Climate Sounder (MCS) Instrument of the Mars Reconnaissance Orbiter (MRO) spacecraft. The instrument scans the Martian atmosphere almost continuously to systematically acquire weather and climate observations over time. Its primary components are an optical bench that houses dual telescopes with a total of nine channels for visible and infrared sensing, and a two axis gimbal that provides pointing capabilities. Both rotating joints consist of an integrated actuator with a hybrid planetary/harmonic transmission and a twist cap section that enables the electrical wiring to pass through the rotating joint. Micro stepping is used to reduce spacecraft disturbance torques to acceptable levels while driving the stepper motors. To ensure survivability over its four year life span, suitable mechanical components, lubrication, and an active temperature control system were incorporated. Some life test results and lessons learned are provided to serve as design guidelines for actuator parts and flex cables.

  8. Using instrumental leadership to manage change.

    Science.gov (United States)

    Lesic, S A

    1999-01-01

    Effective leadership is the key factor in directing and influencing change in an organization. In today's healthcare environment, leaders have less time to make decisions that will ensure their organization's survival, a fact that has forced them to recreate the way they do business and be cognizant of ways to remain competitive. In the environment of change, a new type of leader is needed--the instrumental leader--one who combines the charismatic traits of envisioning, energizing and enabling with the three key facilitating behaviors of controlling, structuring and rewarding. To these attributes the instrumental leader adds critical thinking, problem solving and a feedback mechanism. Leaders who focus on employees as individuals and on the organization as a whole will achieve greater success. Today's leader must share a picture of the intended reality with the organization's staff, constituents and the community. Those most affected by oncoming change must be included in future planning. A shared vision is, however, an ongoing process, with communication crucial for its success. At some point in the change process, leaders must spend time building teams, clarifying behaviors and administering rewards and punishments. Part of this process involves energizing and aligning employees who will find ways to implement the shared new vision. The instrumental leader understands the need for teams that will form the backbone of the integrated system. Creating objective measures for performance, based on the new shared vision, demonstrates the organization's values better than communication or vision alone. Additional training or dialogue may better clarify the organization's expectations of employees.

  9. Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties.

    Science.gov (United States)

    Bautista, Mary Ann C; Nurjono, Milawaty; Lim, Yee Wei; Dessers, Ezra; Vrijhoef, Hubertus Jm

    2016-12-01

    Policy Points: Investigations on systematic methodologies for measuring integrated care should coincide with the growing interest in this field of research. A systematic review of instruments provides insights into integrated care measurement, including setting the research agenda for validating available instruments and informing the decision to develop new ones. This study is the first systematic review of instruments measuring integrated care with an evidence synthesis of the measurement properties. We found 209 index instruments measuring different constructs related to integrated care; the strength of evidence on the adequacy of the majority of their measurement properties remained largely unassessed. Integrated care is an important strategy for increasing health system performance. Despite its growing significance, detailed evidence on the measurement properties of integrated care instruments remains vague and limited. Our systematic review aims to provide evidence on the state of the art in measuring integrated care. Our comprehensive systematic review framework builds on the Rainbow Model for Integrated Care (RMIC). We searched MEDLINE/PubMed for published articles on the measurement properties of instruments measuring integrated care and identified eligible articles using a standard set of selection criteria. We assessed the methodological quality of every validation study reported using the COSMIN checklist and extracted data on study and instrument characteristics. We also evaluated the measurement properties of each examined instrument per validation study and provided a best evidence synthesis on the adequacy of measurement properties of the index instruments. From the 300 eligible articles, we assessed the methodological quality of 379 validation studies from which we identified 209 index instruments measuring integrated care constructs. The majority of studies reported on instruments measuring constructs related to care integration (33%) and patient

  10. Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties

    Science.gov (United States)

    BAUTISTA, MARY ANN C.; NURJONO, MILAWATY; DESSERS, EZRA; VRIJHOEF, HUBERTUS JM

    2016-01-01

    Policy Points: Investigations on systematic methodologies for measuring integrated care should coincide with the growing interest in this field of research.A systematic review of instruments provides insights into integrated care measurement, including setting the research agenda for validating available instruments and informing the decision to develop new ones.This study is the first systematic review of instruments measuring integrated care with an evidence synthesis of the measurement properties.We found 209 index instruments measuring different constructs related to integrated care; the strength of evidence on the adequacy of the majority of their measurement properties remained largely unassessed. Context Integrated care is an important strategy for increasing health system performance. Despite its growing significance, detailed evidence on the measurement properties of integrated care instruments remains vague and limited. Our systematic review aims to provide evidence on the state of the art in measuring integrated care. Methods Our comprehensive systematic review framework builds on the Rainbow Model for Integrated Care (RMIC). We searched MEDLINE/PubMed for published articles on the measurement properties of instruments measuring integrated care and identified eligible articles using a standard set of selection criteria. We assessed the methodological quality of every validation study reported using the COSMIN checklist and extracted data on study and instrument characteristics. We also evaluated the measurement properties of each examined instrument per validation study and provided a best evidence synthesis on the adequacy of measurement properties of the index instruments. Findings From the 300 eligible articles, we assessed the methodological quality of 379 validation studies from which we identified 209 index instruments measuring integrated care constructs. The majority of studies reported on instruments measuring constructs related to care

  11. Ideology as instrument.

    Science.gov (United States)

    Glassman, Michael; Karno, Donna

    2007-12-01

    Comments on the article by J. T. Jost, which argued that the end-of-ideology claims that emerged in the aftermath of World War II were both incorrect and detrimental to the field of political psychology. M. Glassman and D. Karno make three critical points. First, Jost objectified ideology as a grand strategy implemented at the individual level, rather than as an instrument used for a specific purpose in activity. In doing so, he set ideology up as an "object" that guides human behavior rather than as a rational part of human experience. Second, they take issue with the idea that, because somebody acts in a manner that can be categorized as ideological, there actually is such a thing as ideology separate from that event and/or political experience and that psychologists ought to understand the meaning of ideology in order to understand future human activities as outside observers. Third, Jost seems to see this objective ideology as a unidirectional, causal mechanism for activity, a mechanism that assumes individuals act according to ideology, which eclipses the possibility that immediate ideological positions are the residue of purposeful activity. Glassman and Karno suggest that it may be better to take a pluralistic view of ideology in human action. Where ideology does exist, it is as a purposeful instrument--part of a logically based action to meet some ends-in-view--a mixture of immediate goals tied to secondary belief systems (which have been integrated to serve the material purposes of the purveyors of these ideologies). So if we are to understand ideology, we can only understand it through its use in human activity. (Copyright) 2007 APA.

  12. Space radiation studies. Final report, 22 July 1983-30 June 1989

    International Nuclear Information System (INIS)

    1989-01-01

    Two Active Radiation Dosimeters (ARD's) flown on Spacelab 1, performed without fault and were returned to Space Science Laboratory, MSFC for recalibration. During the flight, performance was monitored at the Huntsville Operations Center (HOSC). Despite some problems with the Shuttle data system handling the verification flight instrumentation (VFI), it was established that the ARD's were operating normally. Postflight calibrations of both units determined that sensitivities were essentially unchanged from preflight values. Flight tapes were received for approx. 60 percent of the flight and it appears that this is the total available. The data was analyzed in collaboration with Space Science Laboratory, MSFC. Also, the Nuclear Radiation Monitor (NRM) was assembled and tested at MSFC. Support was rendered in the areas of materials control and parts were supplied for the supplementary heaters, dome gas-venting device and photomultiplier tube housing. Performance characteristics of some flight-space photomultipliers were measured. The NRM was flown on a balloon-borne test flight and subsequently performed without fault on Spacelab-2. This data was analyzed and published

  13. Space experiments with particle accelerators: SEPAC

    International Nuclear Information System (INIS)

    Obayashi, T.

    1978-01-01

    In this paper, the program of the space experiments with particle accelerators (SEPAC) is described. The SEPAC is to be prepared for the Space Shuttle/First Spacelab Mission. It is planned in the SEPAC to carry out the active and interactive experiments on and in the Earth's ionosphere and magnetosphere. It is also intended to make an initial performance test for the overall program of Spacelab/SEPAC experiments. The instruments to be used are electron beam accelerators, MPD arcjects, and associated diagnostic equipments. The main scientific objectives of the experiments are Vehicle Charge Neutralization, Beam Plasma Physics, and Beam Atmosphere Interactions. The SEPAC system consists of the following subsystems. Those are accelerators, monitoring and diagnostic equipments, and control and data management equipments. The SEPAC functional objectives for experiment operations are SEPAC system checkout, EBA firing test, MPD firing test, electron beam experiments, plasma beam propagation, artificial aurora excitation, equatorial aerochemistry, electron echo experiment, E parallel B experiment, passive experiments, SEPAC system deactivation, and battery charging. Most experiment procedures are carried out by the pre-set computer program. (Kato, T.)

  14. New Submersed Chamber for Calibration of Relative Humidity Instruments at HMI/FSB-LPM

    Science.gov (United States)

    Sestan, D.; Zvizdic, D.; Sariri, K.

    2018-02-01

    This paper gives a detailed description of a new chamber designed for calibration of relative humidity (RH) instruments at Laboratory for Process Measurement (HMI/FSB-LPM). To the present time, the calibrations of RH instruments at the HMI/FSB-LPM were done by comparison method using a climatic chamber of large volume and calibrated dew point hygrometer with an additional thermometer. Since 2010, HMI/FSB-LPM in cooperation with Centre for Metrology and Accreditation in Finland (MIKES) developed the two primary dew point generators which cover the dew point temperature range between - 70 {°}C and 60 {°}C. In order to utilize these facilities for calibrations of the RH instruments, the new chamber was designed, manufactured and installed in the existing system, aiming to extend its range and reduce the related calibration uncertainties. The chamber construction allows its use in a thermostatic bath of larger volume as well as in the climatic chambers. In the scope of this paper, performances of the new chamber were tested while it was submersed in a thermostated bath. The chamber can simultaneously accommodate up to three RH sensors. In order to keep the design of the chamber simple, only cylindrical RH sensors detachable from display units can be calibrated. Possible optimizations are also discussed, and improvements in the design proposed. By using the new chamber, HMI/FSB-LPM reduced the expanded calibration uncertainties (level of confidence 95 %, coverage factor k=2) from 0.6 %rh to 0.25 %rh at 30 %rh (23 {°}C), and from 0.8 %rh to 0.53 %rh at 70 %rh (23 {°}C).

  15. The Development of Point Doppler Velocimeter Data Acquisition and Processing Software

    Science.gov (United States)

    Cavone, Angelo A.

    2008-01-01

    In order to develop efficient and quiet aircraft and validate Computational Fluid Dynamic predications, aerodynamic researchers require flow parameter measurements to characterize flow fields about wind tunnel models and jet flows. A one-component Point Doppler Velocimeter (pDv), a non-intrusive, laser-based instrument, was constructed using a design/develop/test/validate/deploy approach. A primary component of the instrument is software required for system control/management and data collection/reduction. This software along with evaluation algorithms, advanced pDv from a laboratory curiosity to a production level instrument. Simultaneous pDv and pitot probe velocity measurements obtained at the centerline of a flow exiting a two-inch jet, matched within 0.4%. Flow turbulence spectra obtained with pDv and a hot-wire detected the primary and secondary harmonics with equal dynamic range produced by the fan driving the flow. Novel,hardware and software methods were developed, tested and incorporated into the system to eliminate and/or minimize error sources and improve system reliability.

  16. The Break - Even Point and the Leverage Effect – Instruments for Assessing the Economic and Financial Risk

    Directory of Open Access Journals (Sweden)

    Nicoleta Constandache

    2011-12-01

    Full Text Available The establishing by any company, depending on the domain of activity, of anminimumobjective to be attained, so that the business should become profitable, is the aim principle of thisarticle. In order to attain this goal, the assumed risk is considered, which implies the use of certainassessing instruments, as the break-evenpoint and the leverage effect. This approach stands for asignificant step in making strategic decisions, being a way to evaluating company security in case inwhich market conditions become unfavourable.

  17. An Evaluation Instrument for Object-Oriented Example Programs for Novices

    DEFF Research Database (Denmark)

    Christensen, Henrik Bærbak; Börstler, Jürgen; Nordström,, Marie

    objectively and consistently requires some kind of measurement instrument. In this paper, we describe the development and initial validation of an evaluation instrument for example programs, based on three aspects of quality; technical quality, object-oriented quality, and didactical quality. Validation......Examples are important tools for programming education. In this paper, we investigate desirable properties of programming examples from a cognitive and a measurement point of view. We argue that some cognitive aspects of example programs are "caught" by common software measures......, but they are not sufficient to capture all important aspects of understandability. We propose a framework for measuring the understandability of example programs that also considers factors related to the usage context of examples. Research shows that examples play an important role for cognitive skill acquisition. Students...

  18. IOT Overview: IR Instruments

    Science.gov (United States)

    Mason, E.

    In this instrument review chapter the calibration plans of ESO IR instruments are presented and briefly reviewed focusing, in particular, on the case of ISAAC, which has been the first IR instrument at VLT and whose calibration plan served as prototype for the coming instruments.

  19. Development of a Symptom-Based Patient-Reported Outcome Instrument for Functional Dyspepsia: A Preliminary Conceptual Model and an Evaluation of the Adequacy of Existing Instruments.

    Science.gov (United States)

    Taylor, Fiona; Reasner, David S; Carson, Robyn T; Deal, Linda S; Foley, Catherine; Iovin, Ramon; Lundy, J Jason; Pompilus, Farrah; Shields, Alan L; Silberg, Debra G

    2016-10-01

    The aim was to document, from the perspective of the empirical literature, the primary symptoms of functional dyspepsia (FD), evaluate the extent to which existing questionnaires target those symptoms, and, finally, identify any missing evidence that would impact the questionnaires' use in regulated clinical trials to assess treatment efficacy claims intended for product labeling. A literature review was conducted to identify the primary symptoms of FD and existing symptom-based FD patient-reported outcome (PRO) instruments. Following a database search, abstracts were screened and articles were retrieved for review. The primary symptoms of FD were organized into a conceptual model and the PRO instruments were evaluated for conceptual coverage as well as compared against evidentiary requirements presented in the FDA's PRO Guidance for Industry. Fifty-six articles and 16 instruments assessing FD symptoms were reviewed. Concepts listed in the Rome III criteria for FD (n = 7), those assessed by existing FD instruments (n = 34), and symptoms reported by patients in published qualitative research (n = 6) were summarized in the FD conceptual model. Except for vomiting, all of the identified symptoms from the published qualitative research reports were also specified in the Rome III criteria. Only three of the 16 instruments, the Dyspepsia Symptom Severity Index (DSSI), Nepean Dyspepsia Index (NDI), and Short-Form Nepean Dyspepsia Index (SF-NDI), measure all seven FD symptoms defined by the Rome III criteria. Among these three, each utilizes a 2-week recall period and 5-point Likert-type scale, and had evidence of patient involvement in development. Despite their coverage, when these instruments were evaluated in light of regulatory expectations, several issues jeopardized their potential qualification for substantiation of a labeling claim. No existing PRO instruments that measured all seven symptoms adhered to the regulatory principles necessary to support product

  20. An Integrated Approach to Introducing Biofuels, Flash Point, and Vapor Pressure Concepts into an Introductory College Chemistry Lab

    Science.gov (United States)

    Hoffman, Adam R.; Britton, Stephanie L.; Cadwell, Katie D.; Walz, Kenneth A.

    2011-01-01

    Students explore the fundamental chemical concepts of vapor pressure and flash point in a real-world technical context, while gaining insight into the contemporary societal issue of biofuels. Lab activities were developed using a closed-cup instrument to measure the flash point of various biodiesel samples. Pre- and post-tests revealed that the…

  1. Troubleshooting in nuclear instruments

    International Nuclear Information System (INIS)

    1987-06-01

    This report on troubleshooting of nuclear instruments is the product of several scientists and engineers, who are closely associated with nuclear instrumentation and with the IAEA activities in the field. The text covers the following topics: Preamplifiers, amplifiers, scalers, timers, ratemeters, multichannel analyzers, dedicated instruments, tools, instruments, accessories, components, skills, interfaces, power supplies, preventive maintenance, troubleshooting in systems, radiation detectors. The troubleshooting and repair of instruments is illustrated by some real examples

  2. Design and validation of an observational instrument for technical and tactical actions in beach volleyball

    Directory of Open Access Journals (Sweden)

    José Manuel Palao

    2015-06-01

    Full Text Available Technical and tactical actions determine performance in beach volleyball. This research develops and tests an instrument to monitor and evaluate the manner of execution and efficacy of the actions in beach volleyball. The purpose of this paper was to design and validate an observational instrument to analyze technical and tactical actions in beach volleyball. The instrument collects information regarding: a information about the match (context, b information about game situations, c information about technical situations (serve, reception, set, attack, block, and court defense in relation to player execution, role, manner of execution, execution zone, and efficacy, and d information about the result of the play (win-lose and way point is obtained. Instrument design and validation was done in seven stages: a review of literature and consultation of experts; b pilot observation and data analysis; c expert review of instrument (qualitative and quantitative evaluation; d observer training test; e expert review of instrument (content validity; f measurement of the ability of the instrument to discriminate the result of the set; and g measurement of the ability of the instrument to differentiate between competition age groups. The results show that the instrument allows for obtaining objective and valid information about the players and team from offensive and defensive technical and tactical actions, as well as indirectly from physical actions. The instrument can be used, in its entirety or partially, for researching and coaching purposes.

  3. Ontology Based Vocabulary Matching for Oceanographic Instruments

    Science.gov (United States)

    Chen, Yu; Shepherd, Adam; Chandler, Cyndy; Arko, Robert; Leadbetter, Adam

    2014-05-01

    Data integration act as the preliminary entry point as we enter the era of big data in many scientific domains. However the reusefulness of various dataset has met the hurdle due to different initial of interests of different parties, therefore different vocabularies in describing similar or semantically related concepts. In this scenario it is vital to devise an automatic or semi-supervised algorithm to facilitate the convergence of different vocabularies. The Ocean Data Interoperability Platform (ODIP) seeks to increase data sharing across scientific domains and international boundaries by providing a forum to harmonize diverse regional data systems. ODIP participants from the US include the Rolling Deck to Repository (R2R) program, whose mission is to capture, catalog, and describe the underway/environmental sensor data from US oceanographic research vessels and submit the data to public long-term archives. In an attempt to harmonize these regional data systems, especially vocabularies, R2R recognizes the value of the SeaDataNet vocabularies served by the NERC Vocabulary Server (NVS) hosted at the British Oceanographic Data Centre as a trusted, authoritative source for describing many oceanographic research concepts such as instrumentation. In this work, we make use of the semantic relations in the vocabularies served by NVS to build a Bayesian network and take advantage of the idea of entropy in evaluating the correlation between different concepts and keywords. The performance of the model is evaluated against matching instruments from R2R against the SeaDataNet instrument vocabularies based on calculated confidence scores in the instrument pairings. These pairings with their scores can then be analyzed for assertion growing the interoperability of the R2R vocabulary through its links to the SeaDataNet entities.

  4. Wax Point Determinations Using Acoustic Resonance Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Bostick, D.T.; Jubin, R.T.; Schmidt, T.W.

    2001-06-01

    The thermodynamic characterization of the wax point of a given crude is essential in order to maintain flow conditions that prevent plugging of undersea pipelines. This report summarizes the efforts made towards applying an Acoustic Cavity Resonance Spectrometer (ACRS) to the determination of pressures and temperatures at which wax precipitates from crude. Phillips Petroleum Company, Inc., the CRADA participant, supplied the ACRS. The instrumentation was shipped to Dr. Thomas Schmidt of ORNL, the CRADA contractor, in May 2000 after preliminary software development performed under the guidance of Dr. Samuel Colgate and Dr. Evan House of the University of Florida, Gainesville, Fl. Upon receipt it became apparent that a number of modifications still needed to be made before the ACRS could be precisely and safely used for wax point measurements. This report reviews the sequence of alterations made to the ACRS, as well as defines the possible applications of the instrumentation once the modifications have been completed. The purpose of this Cooperative Research and Development Agreement (CRADA) between Phillips Petroleum Company, Inc. (Participant) and Lockheed Martin Energy Research Corporation (Contractor) was the measurement of the formation of solids in crude oils and petroleum products that are commonly transported through pipelines. This information is essential in the proper design, operation and maintenance of the petroleum pipeline system in the United States. Recently, new petroleum discoveries in the Gulf of Mexico have shown that there is a potential for plugging of undersea pipeline because of the precipitation of wax. It is important that the wax points of the expected crude oils be well characterized so that the production facilities for these new wells are capable of properly transporting the expected production. The goal of this work is to perform measurements of solids formation in crude oils and petroleum products supplied by the Participant. It is

  5. Space telescope phase B definition study. Volume 2A: Science instruments, high speed point/area photometer

    Science.gov (United States)

    1976-01-01

    The analysis and preliminary design of a high speed point/area photometer for the space telescope are summarized. The scientific objectives, photometer requirements, and design concepts are presented.

  6. Eddy current testing system for bottom mounted instrumentation welds

    OpenAIRE

    Kobayashi Noriyasu; Ueno Souichi; Suganuma Naotaka; Oodake Tatsuya; Maehara Takeshi; Kasuya Takashi; Ichikawa Hiroya

    2015-01-01

    The capability of eddy current testing (ECT) for the bottom mounted instrumentation (BMI) weld area of reactor vessel in a pressurized water reactor was demonstrated by the developed ECT system and procedure. It is difficult to position and move the probe on the BMI weld area because the area has complexly curved surfaces. The space coordinates and the normal vectors at the scanning points were calculated as the scanning trajectory of probe based on the measured results of surface shape on th...

  7. Bright point study. [of solar corona

    Science.gov (United States)

    Tang, F.; Harvey, K.; Bruner, M.; Kent, B.; Antonucci, E.

    1982-01-01

    Transition region and coronal observations of bright points by instruments aboard the Solar Maximum Mission and high resolution photospheric magnetograph observations on September 11, 1980 are presented. A total of 31 bipolar ephemeral regions were found in the photosphere from birth in 9.3 hours of combined magnetograph observations from three observatories. Two of the three ephemeral regions present in the field of view of the Ultraviolet Spectrometer-Polarimeter were observed in the C IV 1548 line. The unobserved ephemeral region was determined to be the shortest-lived (2.5 hr) and lowest in magnetic flux density (13G) of the three regions. The Flat Crystal Spectrometer observed only low level signals in the O VIII 18.969 A line, which were not statistically significant to be positively identified with any of the 16 ephemeral regions detected in the photosphere. In addition, the data indicate that at any given time there lacked a one-to-one correspondence between observable bright points and photospheric ephemeral regions, while more ephemeral regions were observed than their counterparts in the transition region and the corona.

  8. Validation of the force and frequency characteristics of the activator adjusting instrument: effectiveness as a mechanical impedance measurement tool.

    Science.gov (United States)

    Keller, T S; Colloca, C J; Fuhr, A W

    1999-02-01

    To determine the dynamic force-time and force-frequency characteristics of the Activator Adjusting Instrument and to validate its effectiveness as a mechanical impedance measurement device; in addition, to refine or optimize the force-frequency characteristics of the Activator Adjusting Instrument to provide enhanced dynamic structural measurement reliability and accuracy. An idealized test structure consisting of a rectangular steel beam with a static stiffness similar to that of the human thoracolumbar spine was used for validation of a method to determine the dynamic mechanical response of the spine. The Activator Adjusting Instrument equipped with a load cell and accelerometer was used to measure forces and accelerations during mechanical excitation of the steel beam. Driving point and transfer mechanical impedance and resonant frequency of the beam were determined by use of a frequency spectrum analysis for different force settings, stylus masses, and stylus tips. Results were compared with beam theory and transfer impedance measurements obtained by use of a commercial electronic PCB impact hammer. The Activator Adjusting Instrument imparted a very complex dynamic impact comprising an initial high force (116 to 140 N), short duration pulse (analysis of the Activator Adjusting Instrument impulse indicated that the Activator Adjusting Instrument has a variable force spectrum and delivers its peak energy at a frequency of 20 Hz. Added masses and different durometer stylus tips had very little influence on the Activator Adjusting Instrument force spectrum. The resonant frequency of the beam was accurately predicted by both the Activator Adjusting Instrument and electronic PCB impact hammer, but variations in the magnitude of the driving point impedance at the resonant frequency were high (67%) compared with the transfer impedance measurements obtained with the electronic PCB impact hammer, which had a more uniform force spectrum and was more repeatable (frequency

  9. Development of an instrument to assess the health related quality of life of kidney stone formers.

    Science.gov (United States)

    Penniston, Kristina L; Nakada, Stephen Y

    2013-03-01

    Urolithiasis is associated with pain and other decreases in health related quality of life, yet there is no urolithiasis specific instrument to measure quality of life. Quality of life is an important end point in the management of urolithiasis. Therefore, we developed the Wisconsin StoneQOL, a disease specific instrument to assess the quality of life of patients with urolithiasis. Patients and urology providers identified important concepts related to quality of life of stone formers in groups and in individual cognitive interviews. Patients were recurrent stone formers including those with and those without current stones. A preliminary instrument was created, followed by patient feedback and item reduction. A 28-question instrument was ultimately developed which was tested for reliability as well as internal face, construct and discriminant validity in 248 stone formers. The internal consistency (for questions within domains) was high (mean Cronbach's α = 0.81). Correlation between domains was confirmed (Cronbach's α = 0.86). Discriminant validity was shown as stone formers with current stones scored lower than those who were stone-free. Among patients with active stones, those with symptoms scored lower on most questions and for the total score (p instrument that captures the unique symptoms and challenges associated with urolithiasis. As such, the Wisconsin StoneQOL is capable of assessing the health related quality of life of stone formers at various points along the disease continuum. Future assessment will establish minimal clinically important differences for use in individual patients. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  10. Can the Afinion HbA1c Point-of-Care instrument be an alternative method for the Tosoh G8 in the case of Hb-Tacoma?

    Science.gov (United States)

    Lenters-Westra, Erna; Strunk, Annuska; Campbell, Paul; Slingerland, Robbert J

    2017-02-01

    Hb-variant interference when reporting HbA1c has been an ongoing challenge since HbA1c was introduced to monitor patients with diabetes mellitus. Most Hb-variants show an abnormal chromatogram when cation-exchange HPLC is used for the determination of HbA1c. Unfortunately, the Tosoh G8 generates what appears to be normal chromatogram in the presence of Hb-Tacoma, yielding a falsely high HbA1c value. The primary aim of the study was to investigate if the Afinion HbA1c point-of-care (POC) instrument could be used as an alternative method for the Tosoh G8 when testing for HbA1c in the presence of Hb-Tacoma. Whole blood samples were collected in K 2 EDTA tubes from individuals homozygous for HbA (n = 40) and heterozygous for Hb-Tacoma (n = 20). Samples were then immediately analyzed with the Afinion POC instrument. After analysis, aliquots of each sample were frozen at -80 °C. The frozen samples were shipped on dry ice to the European Reference Laboratory for Glycohemoglobin (ERL) and analyzed with three International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) and National Glycohemoglobin Standardization Program (NGSP) Secondary Reference Measurement Procedures (SRMPs). The Premier Hb9210 was used as the reference method. When compared to the reference method, samples with Hb-Tacoma yielded mean relative differences of 31.8% on the Tosoh G8, 21.5% on the Roche Tina-quant Gen. 2 and 16.8% on the Afinion. The Afinion cannot be used as an alternative method for the Tosoh G8 when testing for HbA1c in the presence of Hb-Tacoma.

  11. Multi-hybrid instrumentations with smartphones and smartpads for innovative in-field and POC diagnostics

    Science.gov (United States)

    Hofmann, Dietrich; Dittrich, Paul-Gerald; Gärtner, Claudia; Klemm, Richard

    2013-03-01

    Aim of the paper is the orientation of research and development on a completely new approach to innovative in-field and point of care diagnostics in industry, biology and medicine. Central functional modules are smartphones and/or smart pads supplemented by additional hardware apps and software apps. Specific examples are given for numerous practical applications concerning optodigital instrumentations. The methodical classification distinguishes between different levels for combination of hardware apps (hwapps) and software apps (swapps) with smartphones and/or smartpads. These methods are fundamental enablers for the transformation from stationary conventional laboratory diagnostics into mobile innovative in-field and point of care diagnostics. The innovative approach opens so far untapped enormous markets due to the convenience, reliability and affordability of smartphone and/or smartpad instruments. A highly visible advantage of smartphones and/or smartpads is the huge number of their distribution, their worldwide connectivity via cloud services and the experienced capability of their users for practical operations.

  12. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1984-09-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  13. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1985-01-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  14. Digital analyzer for point processes based on first-in-first-out memories

    Science.gov (United States)

    Basano, Lorenzo; Ottonello, Pasquale; Schiavi, Enore

    1992-06-01

    We present an entirely new version of a multipurpose instrument designed for the statistical analysis of point processes, especially those characterized by high bunching. A long sequence of pulses can be recorded in the RAM bank of a personal computer via a suitably designed front end which employs a pair of first-in-first-out (FIFO) memories; these allow one to build an analyzer that, besides being simpler from the electronic point of view, is capable of sustaining much higher intensity fluctuations of the point process. The overflow risk of the device is evaluated by treating the FIFO pair as a queueing system. The apparatus was tested using both a deterministic signal and a sequence of photoelectrons obtained from laser light scattered by random surfaces.

  15. High Response Dew Point Measurement System for a Supersonic Wind Tunnel

    Science.gov (United States)

    Blumenthal, Philip Z.

    1996-01-01

    A new high response on-line measurement system has been developed to continuously display and record the air stream dew point in the NASA Lewis 10 x 10 supersonic wind tunnel. Previous instruments suffered from such problems as very slow response, erratic readings, and high susceptibility to contamination. The system operates over the entire pressure level range of the 10 x 10 SWT, from less than 2 psia to 45 psia, without the need for a vacuum pump to provide sample flow. The system speeds up tunnel testing, provides large savings in tunnel power costs and provides the dew point input for the data-reduction subroutines which calculate test section conditions.

  16. Influence of different manufacturing methods on the cyclic fatigue of rotary nickel-titanium endodontic instruments.

    Science.gov (United States)

    Rodrigues, Renata C V; Lopes, Hélio P; Elias, Carlos N; Amaral, Georgiana; Vieira, Victor T L; De Martin, Alexandre S

    2011-11-01

    The aim of this study was to evaluate, by static and dynamic cyclic fatigue tests, the number of cycles to fracture (NCF) 2 types of rotary NiTi instruments: Twisted File (SybronEndo, Orange, CA), which is manufactured by a proprietary twisting process, and RaCe files (FKG Dentaire, La Chaux-de-Fonds, Switzerland), which are manufactured by grinding. Twenty Twisted Files (TFs) and 20 RaCe files #25/.006 taper instruments were allowed to rotate freely in an artificial curved canal at 310 rpm in a static or a dynamic model until fracture occurred. Measurements of the fractured fragments showed that fracture occurred at the point of maximum flexure in the midpoint of the curved segment. The NCF was significantly lower for RaCe instruments compared with TFs. The NCF was also lower for instruments subjected to the static test compared with the dynamic model in both groups. Scanning electron microscopic analysis revealed ductile morphologic characteristics on the fractured surfaces of all instruments and no plastic deformation in their helical shafts. Rotary NiTi endodontic instruments manufactured by twisting present greater resistance to cyclic fatigue compared with instruments manufactured by grinding. The fracture mode observed in all instruments was of the ductile type. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. The static and dynamic efficiency of instruments of promotion of renewables

    International Nuclear Information System (INIS)

    Finon, D; Menanteau, P.

    2003-01-01

    Results of a comparative analysis of the economic and social efficiency of the instruments used to promote renewable energy sources are discussed. The analysis was carried out first from a static point of view and then using dynamic criteria, to ascertain the ability of the instruments to stimulate technological progress and cost reduction. The first part of the analysis is devoted to characterization of the rationale of these policies in a cost-efficiency framework, followed by an analysis of the instruments in relation to the classic discussion of environmental policy that opposes price-based approaches versus quantity-based approaches. The final part of the analysis examines the incentives to invest and innovate in the context of each framework in relation to the surplus allowed by each policy instrument and its effects on the tendency of manufacturers and renewable energy producers to innovate. The evidence shows that in terms of installed capacity price-based approaches have been superior to the quantity-based approaches that have been used until recently. In contrast, quantity-based approaches have been found to be more efficient for defining and adjusting the overall goals. Adjusting the quotas also provides an indirect way of controlling overall costs. 22 refs., 3 tabs., 6 figs

  18. The geostationary Earth radiation budget (GERB) instrument on EUMETSAT's MSG satellite

    Science.gov (United States)

    Sandford, M. C. W.; Allan, P. M.; Caldwell, M. E.; Delderfield, J.; Oliver, M. B.; Sawyer, E.; Harries, J. E.; Ashmall, J.; Brindley, H.; Kellock, S.; Mossavati, R.; Wrigley, R.; Llewellyn-Jones, D.; Blake, O.; Butcher, G.; Cole, R.; Nelms, N.; DeWitte, S.; Gloesener, P.; Fabbrizzi, F.

    2003-12-01

    Geostationary Earth radiation budget (GERB) is an Announcement of Opportunity Instrument for EUMETSAT's Meteosat Second Generation (MSG) satellite. GERB will make accurate measurements of the Earth Radiation Budget from geostationary orbit, provide an absolute reference calibration for LEO Earth radiation budget instruments and allow studies of the energetics of atmospheric processes. By operating from geostationary orbit, measurements may be made many times a day, thereby providing essentially perfect diurnal sampling of the radiation balance between reflected and emitted radiance for that area of the globe within the field of view. GERB will thus complement other instruments which operate in low orbit and give complete global coverage, but with poor and biased time resolution. GERB measures infrared radiation in two wavelength bands: 0.32-4.0 and 0.32- 30 μm, with a pixel element size of 44 km at sub-satellite point. This paper gives an overview of the project and concentrates on the design and development of the instrument and ground testing and calibration, and lessons learnt from a short time scale low-budget project. The instrument was delivered for integration on the MSG platform in April 1999 ready for the proposed launch in October 2000, which has now been delayed probably to early 2002. The ground segment is being undertaken by RAL and RMIB and produces near real-time data for meteorological applications in conjunction with the main MSG imager—SEVERI. Climate research and other applications which are being developed under a EU Framework IV pilot project will be served by fully processed data. Because of the relevance of the observations to climate change, it is planned to maintain an operating instrument in orbit for at least 3.5 years. Two further GERB instruments are being built for subsequent launches of MSG.

  19. Development of experimental concepts for investigating the strength behavior of fine-grained cohesive soil in the Spacelab/space shuttle zero-g environment

    Science.gov (United States)

    Bonaparte, R.; Mitchell, J. K.

    1981-01-01

    Three different sets of tests are proposed for the NASA Spacelab experimental program. The first of tests, designed to measure the true cohesion of several different soils, would be carried out in space through use of a specially prepared direct shear apparatus. As part of this first series of tests, it is recommended that a set of drained unconfined compression tests be performed terrestrially on the same soils as tested in space. A form of the direct tension test is planned to measure the true tensile strength of the same types of soils used in the first series of tests. The direct tension tests could be performed terrestrially. The combined results of the direct shear tests, direct tension tests, and unconfined compression tests can be used to construct approximate failure envelopes for the soils tested in the region of the stress origin. Relationships between true cohesion and true tensile strength can also be investigated. In addition, the role of physio-chemical variables should be studied. The third set of tests involves using a multiaxial cubical or true triaxial test apparatus to investigate the influence of gravity induced fabric anisotropy and stress nonhomogeneities on the stress strain behavior of cohesive soils at low effective stress levels. These tests would involve both in space and terrestrial laboratory testing.

  20. Early results from the Whisper instrument on Cluster: An overview

    DEFF Research Database (Denmark)

    Decreau, P.M.E.; Fergeau, P.; Krasnoselskikh, V.

    2001-01-01

    The Whisper instrument yields two data sets: (i) the electron density determined via the relaxation sounder, and (ii) the spectrum of natural plasma emissions in the frequency band 2-80 kHz. Both data sets allow for the three-dimensional exploration of the magnetosphere by the Cluster mission...... the drift velocity of density structures. Wave observations are also of crucial interest for studying small-scale structures, as demonstrated in an example in the fore-shock region. Early results from the Whisper instrument are very encouraging, and demonstrate that the four-point Cluster measurements...... largely overcomes the limited telemetry allocation. The natural emissions are usually related to the plasma frequency, as identified by the sounder, and the combination of an active sounding operation and a passive survey operation provides a time resolution for the total density determination of 2.2 s...

  1. Instrumentation for a radon research house

    International Nuclear Information System (INIS)

    Nazaroff, W.W.; Revzan, K.L.; Robb, A.W.

    1981-07-01

    A highly automated monitoring and control system for studying radon and radon-daughter behavior in residences has been designed and built. The system has been installed in a research house, a test space contained in a two-story wood-framed building, which allows us to conduct controlled studies of (1) pollutant transport within and between rooms, (2) the dynamics of radon daughter behavior, and (3) techniques for controlling radon and radon daughters. The system's instrumentation is capable of measuring air-exchange rate, four-point radon concentration, individual radon daughter concentrations, indoor temerature and humidity, and outdoor weather parameters (temperature, humidity, modules, wind speed, and wind direction). It is also equipped with modules that control the injection of radon and tracer gas into the test space, the operation of the forced-air furnace, the mechanical ventilation system, and the mixing fans located in each room. A microcomputer controls the experiments and records the data on magnetic tape and on a printing terminal. The data on tape is transferred to a larger computer system for reduction and analysis. In this paper we describe the essential design and function of the instrumentation system, as a whole, singling out those components that measure ventilation rate, radon concentration, and radon daughter concentrations

  2. Improvement of lithium chloride dew-point hygrometer for direct reading and controlling of relative humidity

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, X.Z.; Chu, Y.

    1986-01-01

    The lithium chloride dew-point hygrometer has many advantages over other types of hygrometers. However, it only reads and controls the dew-point temperature of air instead of the relative humidity, which is more important in industry, agriculture, food storage, and hygiene. This paper describes a new hygrometer which is based on the same principle as the lithium chloride dew-point hygrometer, but it can read and control the relative humidity directly. The instrument is quick in response and the ranges of temperature and relative humidity are quite large. Its accuracy is normally within 3% RH and its precision is within 2% RH.

  3. The dynamic efficiency of instruments for stimulating the dissemination of renewable energy technologies

    Energy Technology Data Exchange (ETDEWEB)

    Lamy, M.L.; Menanteau, Ph.; Finon, D.

    2002-06-01

    In this paper the authors examine the efficiency of the different incentive schemes for the development of renewable energy sources, both from a theoretical point of view by comparing price-based approaches with quantity-based approaches, and from a practical point of view by looking at concrete examples of how these different instruments have been implemented. The main focus is on the dynamic efficiency of the different instruments taking as an illustration the recent experience of stimulating wind power development in European countries. Theoretically, price-based or quantity-based approaches should be comparable methods for achieving renewable energy targets but uncertainty and implementing conditions may modify the symmetry of the two approaches. Accordingly, fixed feed in tariffs have clearly been superior to competitive bidding as far as installed capacity or industrial development are concerned. Finally the paper also examines the possibility that the price versus quantity issue could be reactivated with the emergence of the green certificate markets which present theoretical advantages of quota-based approaches without the limitations of competitive bidding systems. (author)

  4. Status of safeguards instrumentation

    International Nuclear Information System (INIS)

    Higinbotham, W.A.

    The International Atomic Energy Agency is performing safeguards at some nuclear power reactors, 50 bulk processing facilities, and 170 research facilities. Its verification activities require the use of instruments to measure nuclear materials and of surveillance instruments to maintain continuity of knowledge of the locations of nuclear materials. Instruments that are in use and under development to measure weight, volume, concentration, and isotopic composition of nuclear materials, and the major surveillance instruments, are described in connection with their uses at representative nuclear facilities. The current status of safeguards instrumentation and the needs for future development are discussed

  5. Early modern mathematical instruments.

    Science.gov (United States)

    Bennett, Jim

    2011-12-01

    In considering the appropriate use of the terms "science" and "scientific instrument," tracing the history of "mathematical instruments" in the early modern period is offered as an illuminating alternative to the historian's natural instinct to follow the guiding lights of originality and innovation, even if the trail transgresses contemporary boundaries. The mathematical instrument was a well-defined category, shared across the academic, artisanal, and commercial aspects of instrumentation, and its narrative from the sixteenth to the eighteenth century was largely independent from other classes of device, in a period when a "scientific" instrument was unheard of.

  6. Instrumental Capital

    Directory of Open Access Journals (Sweden)

    Gabriel Valerio

    2007-07-01

    Full Text Available During the history of human kind, since our first ancestors, tools have represented a mean to reach objectives which might otherwise seemed impossibles. In the called New Economy, where tangibles assets appear to be losing the role as the core element to produce value versus knowledge, tools have kept aside man in his dairy work. In this article, the author's objective is to describe, in a simple manner, the importance of managing the organization's group of tools or instruments (Instrumental Capital. The characteristic conditions of this New Economy, the way Knowledge Management deals with these new conditions and the sub-processes that provide support to the management of Instrumental Capital are described.

  7. Designing an Instrument to Measure the QoS of a Spanish Virtual Store

    Science.gov (United States)

    de Abajo, Beatriz Sainz; de La Torre Díez, Isabel; Salcines, Enrique García; Fernández, Javier Burón; Pernas, Francisco Díaz; Coronado, Miguel López; de Castro Lozano, Carlos

    This article describes the development of an instrument, in the form of a survey, which is distributed to users of a B2C website selling electronic books in order to ascertain their satisfaction. The opinions compiled from a pilot sample and the exploratory factor analysis carried out point to factors that best summarise the quality of the application analysed here. Analysis of the initial survey, with a total of 40 items, shaped the final instrument, encompassing 18 items divided into 6 dimensions, which measure the perceptions of users of the application in order to improve the contents of the website. Subsequently, a confirmatory factorial analysis is performed, ensuring the reliability of the study and which confirms that the structure of the instrument developed truly measures service quality in accordance with the requirements of the website in terms of offering a space that fulfils consumer expectations in the Information Society.

  8. Acoustic emission measurement during instrumented impact tests

    International Nuclear Information System (INIS)

    Crostack, H.A.; Engelhardt, A.H.

    1983-01-01

    Results of instrumented impact tests are discussed. On the one hand the development of the loading process at the hammer tup was recorded by means of a piezoelectric transducer. This instrumentation supplied a better representation of the load versus time than the conventional strain gauges. On the other hand the different types of acoustic emission occurring during a test could be separated. The acoustic emission released at the impact of the hammer onto the specimen is of lower frequency and its spectrum is strongly decreasing with increasing frequency. Plastic deformation also emits signals of lower frequency that are of quasi-continuous character. Both signal types can be discriminated by filtering. As a consequence typical burst signal were received afterwards that can be correlated with crack propagation. Their spectra exhibit considerable portions up to about 1.9 MHz. The development in time of the burst signals points to the kind of crack propagation resp. its sequence of appearance. However, definitive comparison between load and acoustic emission should become possible, only when the disadvantages of the common load measurement can be reduced, e.g. by determining the load directly at the specimen instead of the hammer tup

  9. Evaluating musical instruments

    International Nuclear Information System (INIS)

    Campbell, D. Murray

    2014-01-01

    Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians

  10. A flexible mobile-device biosensing instrumentation platform for point-of-care medical diagnostics applications

    DEFF Research Database (Denmark)

    Patou, François; Pfreundt, Andrea; Zulfiqar, Azeem

    2014-01-01

    helping to address this challenge. Specifically, Lab-on-Chip (LoC) devices have a key role to play in the advent of Point-of-Care (PoC) medical applications, driving a shift of the medical diagnostics paradigm and the transition from a centralized, technical, high-throughput biological sample analysis...... programmable electrical readout from LoCs potentially comprehending varied transducers addressing different targeted biological markers. A smart-phone/tablet docking-station embeds the hardware interface necessary for the implementation of a smart-phone digital lock-in amplifier. The platform is tested...

  11. International Survey on agriculture-climate change policy instruments

    Energy Technology Data Exchange (ETDEWEB)

    Fernagut, M.; Priem, M.; Sorgeloos, L.

    2011-09-15

    The title study provides an international overview of agriculture-climate change policy instruments for the reduction of methane and nitrous oxide emissions. The aim of this study is to clarify how national and/or international agriculture-climate-policies could or should be instrumented during the coming three to five years to achieve significant emission reductions of methane and nitrous oxide in the Dutch agricultural sector by 2020. The study includes an international survey, a quick-scan inventory of useful and inspiring examples of policy and reduction measures to reduce non CO2 greenhouse gases. ERM used an approach consisting out of three phases. In the first phase countries were selected on the basis of emissions and Kyoto protocol targets. In the second phase policy measures of these countries were listed, based on publicly available national and international sources. In a third phase a sub-set of this selection was analyzed in-depth through communications with local focal points and additional review of policy documents, to enhance the understanding of context, impact and results of each of these policies and measures.

  12. Performance evaluation of the microINR® point-of-care INR-testing system.

    Science.gov (United States)

    Joubert, J; van Zyl, M C; Raubenheimer, J

    2018-04-01

    Point-of-care International Normalised Ratio (INR) testing is used frequently. We evaluated the microINR ® POC system for accuracy, precision and measurement repeatability, and investigated instrument and test chip variability and error rates. Venous blood INRs of 210 patients on warfarin were obtained with Thromborel ® S on the Sysmex CS-2100i ® analyser and compared with capillary blood microINR ® values. Precision was assessed using control materials. Measurement repeatability was calculated on 51 duplicate finger-prick INRs. Triplicate finger-prick INRs using three different instruments (30 patients) and three different test chip lots (29 patients) were used to evaluate instrument and test chip variability. Linear regression analysis of microINR ® and Sysmex CS2100i ® values showed a correlation coefficient of 0.96 (P < .0001) and a positive proportional bias of 4.4%. Dosage concordance was 93.8% and clinical agreement 95.7%. All acceptance criteria based on ISO standard 17593:2007 system accuracy requirements were met. Control material coefficients of variation (CV) varied from 6.2% to 16.7%. The capillary blood measurement repeatability CV was 7.5%. No significant instrument (P = .93) or test chip (P = .81) variability was found, and the error rate was low (2.8%). The microINR ® instrument is accurate and precise for monitoring warfarin therapy. © 2017 John Wiley & Sons Ltd.

  13. Verification of the Solar Dynamics Observatory High Gain Antenna Pointing Algorithm Using Flight Data

    Science.gov (United States)

    Bourkland, Kristin L.; Liu, Kuo-Chia

    2011-01-01

    The Solar Dynamics Observatory (SDO) is a NASA spacecraft designed to study the Sun. It was launched on February 11, 2010 into a geosynchronous orbit, and uses a suite of attitude sensors and actuators to finely point the spacecraft at the Sun. SDO has three science instruments: the Atmospheric Imaging Assembly (AIA), the Helioseismic and Magnetic Imager (HMI), and the Extreme Ultraviolet Variability Experiment (EVE). SDO uses two High Gain Antennas (HGAs) to send science data to a dedicated ground station in White Sands, New Mexico. In order to meet the science data capture budget, the HGAs must be able to transmit data to the ground for a very large percentage of the time. Each HGA is a dual-axis antenna driven by stepper motors. Both antennas transmit data at all times, but only a single antenna is required in order to meet the transmission rate requirement. For portions of the year, one antenna or the other has an unobstructed view of the White Sands ground station. During other periods, however, the view from both antennas to the Earth is blocked for different portions of the day. During these times of blockage, the two HGAs take turns pointing to White Sands, with the other antenna pointing out to space. The HGAs handover White Sands transmission responsibilities to the unblocked antenna. There are two handover seasons per year, each lasting about 72 days, where the antennas hand off control every twelve hours. The non-tracking antenna slews back to the ground station by following a ground commanded trajectory and arrives approximately 5 minutes before the formerly tracking antenna slews away to point out into space. The SDO Attitude Control System (ACS) runs at 5 Hz, and the HGA Gimbal Control Electronics (GCE) run at 200 Hz. There are 40 opportunities for the gimbals to step each ACS cycle, with a hardware limitation of no more than one step every three GCE cycles. The ACS calculates the desired gimbal motion for tracking the ground station or for slewing

  14. Analysis of the stochastic channel model by Saleh & Valenzuela via the theory of point processes

    DEFF Research Database (Denmark)

    Jakobsen, Morten Lomholt; Pedersen, Troels; Fleury, Bernard Henri

    2012-01-01

    and underlying features, like the intensity function of the component delays and the delaypower intensity. The flexibility and clarity of the mathematical instruments utilized to obtain these results lead us to conjecture that the theory of spatial point processes provides a unifying mathematical framework...

  15. The VUV instrument SPICE for Solar Orbiter: performance ground testing

    Science.gov (United States)

    Caldwell, Martin E.; Morris, Nigel; Griffin, Douglas K.; Eccleston, Paul; Anderson, Mark; Pastor Santos, Carmen; Bruzzi, Davide; Tustain, Samuel; Howe, Chris; Davenne, Jenny; Grundy, Timothy; Speight, Roisin; Sidher, Sunil D.; Giunta, Alessandra; Fludra, Andrzej; Philippon, Anne; Auchere, Frederic; Hassler, Don; Davila, Joseph M.; Thompson, William T.; Schuehle, Udo H.; Meining, Stefan; Walls, Buddy; Phelan, P.; Dunn, Greg; Klein, Roman M.; Reichel, Thomas; Gyo, Manfred; Munro, Grant J.; Holmes, William; Doyle, Peter

    2017-08-01

    SPICE is an imaging spectrometer operating at vacuum ultraviolet (VUV) wavelengths, 70.4 - 79.0 nm and 97.3 - 104.9 nm. It is a facility instrument on the Solar Orbiter mission, which carries 10 science instruments in all, to make observations of the Sun's atmosphere and heliosphere, at close proximity to the Sun, i.e to 0.28 A.U. at perihelion. SPICE's role is to make VUV measurements of plasma in the solar atmosphere. SPICE is designed to achieve spectral imaging at spectral resolution >1500, spatial resolution of several arcsec, and two-dimensional FOV of 11 x16arcmins. The many strong constraints on the instrument design imposed by the mission requirements prevent the imaging performance from exceeding those of previous instruments, but by being closer to the sun there is a gain in spatial resolution. The price which is paid is the harsher environment, particularly thermal. This leads to some novel features in the design, which needed to be proven by ground test programs. These include a dichroic solar-transmitting primary mirror to dump the solar heat, a high in-flight temperature (60deg.C) and gradients in the optics box, and a bespoke variable-line-spacing grating to minimise the number of reflective components used. The tests culminate in the systemlevel test of VUV imaging performance and pointing stability. We will describe how our dedicated facility with heritage from previous solar instruments, is used to make these tests, and show the results, firstly on the Engineering Model of the optics unit, and more recently on the Flight Model. For the keywords, select up to 8 key terms for a search on your manuscript's subject.

  16. Integrated optical detection of autonomous capillary microfluidic immunoassays:a hand-held point-of-care prototype.

    Science.gov (United States)

    Novo, P; Chu, V; Conde, J P

    2014-07-15

    The miniaturization of biosensors using microfluidics has potential in enabling the development of point-of-care devices, with the added advantages of reduced time and cost of analysis with limits-of-detection comparable to those obtained through traditional laboratory techniques. Interfacing microfluidic devices with the external world can be difficult especially in aspects involving fluid handling and the need for simple sample insertion that avoids special equipment or trained personnel. In this work we present a point-of-care prototype system by integrating capillary microfluidics with a microfabricated photodiode array and electronic instrumentation into a hand-held unit. The capillary microfluidic device is capable of autonomous and sequential fluid flow, including control of the average fluid velocity at any given point of the analysis. To demonstrate the functionality of the prototype, a model chemiluminescence ELISA was performed. The performance of the integrated optical detection in the point-of-care prototype is equal to that obtained with traditional bench-top instrumentation. The photodiode signals were acquired, displayed and processed by a simple graphical user interface using a computer connected to the microcontroller through USB. The prototype performed integrated chemiluminescence ELISA detection in about 15 min with a limit-of-detection of ≈2 nM with an antibody-antigen affinity constant of ≈2×10(7) M(-1). Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Instrument Modeling and Synthesis

    Science.gov (United States)

    Horner, Andrew B.; Beauchamp, James W.

    During the 1970s and 1980s, before synthesizers based on direct sampling of musical sounds became popular, replicating musical instruments using frequency modulation (FM) or wavetable synthesis was one of the “holy grails” of music synthesis. Synthesizers such as the Yamaha DX7 allowed users great flexibility in mixing and matching sounds, but were notoriously difficult to coerce into producing sounds like those of a given instrument. Instrument design wizards practiced the mysteries of FM instrument design.

  18. Instrumentation for Nuclear Applications

    International Nuclear Information System (INIS)

    1998-01-01

    The objective of this project was to develop and coordinate nuclear instrumentation standards with resulting economies for the nuclear and radiation fields. There was particular emphasis on coordination and management of the Nuclear Instrument Module (NIM) System, U.S. activity involving the CAMAC international standard dataway system, the FASTBUS modular high-speed data acquisition and control system and processing and management of national nuclear instrumentation and detector standards, as well as a modest amount of assistance and consultation services to the Pollutant Characterization and Safety Research Division of the Office of Health and Environmental Research. The principal accomplishments were the development and maintenance of the NIM instrumentation system that is the predominant instrumentation system in the nuclear and radiation fields worldwide, the CAMAC digital interface system in coordination with the ESONE Committee of European Laboratories, the FASTBUS high-speed system and numerous national and international nuclear instrumentation standards

  19. Temperature and pressure instrumentation in WWERs and their testing

    International Nuclear Information System (INIS)

    Por, G.

    1998-01-01

    A description of WWER model V-213 reactors of second generation is presented and compared to analogous NPPs including description of temperature and pressure instrumentation which was tested at Paks NPP. From the experimental results it was concluded that measured response of in core neutron detector to bubbles strongly depends on the relative position of detector and point bubble injection. Neutron noise spectra show characteristic sink when the origin of bubbles is close to the detectors. Dependence of phase behaviour on the boiling conditions is included as well

  20. Instrumentation for mass spectrometry: 1997

    Energy Technology Data Exchange (ETDEWEB)

    McLuckey, S.A.

    1997-08-01

    All mass spectrometry experiments involve the manipulation of material, an interface with the mass spectrometer, ionization, ion manipulation/analysis, detection and data collection/reduction. Each of these elements involve instrumentation. The wide range of species now amenable to mass spectrometry and the diverse areas of physical science in which it plays a role have led to a seemingly unlimited array of instrumental combinations. However, only a limited number of mass analyzers, and their combinations, dominate. The dominant analyzers include time-of-flight, Fourier transform ion cyclotron resonance, the Paul trap, the mass filter, and the sector mass spectrometer. Why there are so few (or so many, depending upon one`s point of view) can be understood upon consideration of a set of mass analyzer figures of merit. These include mass resolution, mass accuracy, mass range, dynamic range, abundance sensitivity, precision, efficiency, speed, MS{sup n} capability, compatibility with the ionizer, cost, and size. The most appropriate form of mass spectrometry is determined by the priorities of the particular measurement placed on the various mass analyzer characteristics and the relative strengths of the analyzers in meeting the requirements. Each of the analyzer types has a unique set of figures of merit that makes it optimally suited for particular applications. This paper discusses these figures of merit, provides data illustrating recent developments for each analyzer type, and gives the figures of merit of each type of analyzer as they stand in 1997. 101 refs., 24 figs.

  1. On Representative Spaceflight Instrument and Associated Instrument Sensor Web Framework

    Science.gov (United States)

    Kizhner, Semion; Patel, Umeshkumar; Vootukuru, Meg

    2007-01-01

    Sensor Web-based adaptation and sharing of space flight mission resources, including those of the Space-Ground and Control-User communication segment, could greatly benefit from utilization of heritage Internet Protocols and devices applied for Spaceflight (SpaceIP). This had been successfully demonstrated by a few recent spaceflight experiments. However, while terrestrial applications of Internet protocols are well developed and understood (mostly due to billions of dollars in investments by the military and industry), the spaceflight application of Internet protocols is still in its infancy. Progress in the developments of SpaceIP-enabled instrument components will largely determine the SpaceIP utilization of those investments and acceptance in years to come. Likewise SpaceIP, the development of commercial real-time and instrument colocated computational resources, data compression and storage, can be enabled on-board a spacecraft and, in turn, support a powerful application to Sensor Web-based design of a spaceflight instrument. Sensor Web-enabled reconfiguration and adaptation of structures for hardware resources and information systems will commence application of Field Programmable Arrays (FPGA) and other aerospace programmable logic devices for what this technology was intended. These are a few obvious potential benefits of Sensor Web technologies for spaceflight applications. However, they are still waiting to be explored. This is because there is a need for a new approach to spaceflight instrumentation in order to make these mature sensor web technologies applicable for spaceflight. In this paper we present an approach in developing related and enabling spaceflight instrument-level technologies based on the new concept of a representative spaceflight Instrument Sensor Web (ISW).

  2. Modeling of Highly Instrumented Honeywell Turbofan Engine Tested with Ice Crystal Ingestion in the NASA Propulsion System Laboratory

    Science.gov (United States)

    Veres, Joseph P.; Jorgenson, Philip C. E.; Jones, Scott M.

    2016-01-01

    The Propulsion Systems Laboratory (PSL), an altitude test facility at NASA Glenn Research Center, has been used to test a highly instrumented turbine engine at simulated altitude operating conditions. This is a continuation of the PSL testing that successfully duplicated the icing events that were experienced in a previous engine (serial LF01) during flight through ice crystal clouds, which was the first turbofan engine tested in PSL. This second model of the ALF502R-5A serial number LF11 is a highly instrumented version of the previous engine. The PSL facility provides a continuous cloud of ice crystals with controlled characteristics of size and concentration, which are ingested by the engine during operation at simulated altitudes. Several of the previous operating points tested in the LF01 engine were duplicated to confirm repeatability in LF11. The instrumentation included video cameras to visually illustrate the accretion of ice in the low pressure compressor (LPC) exit guide vane region in order to confirm the ice accretion, which was suspected during the testing of the LF01. Traditional instrumentation included static pressure taps in the low pressure compressor inner and outer flow path walls, as well as total pressure and temperature rakes in the low pressure compressor region. The test data was utilized to determine the losses and blockages due to accretion in the exit guide vane region of the LPC. Multiple data points were analyzed with the Honeywell Customer Deck. A full engine roll back point was modeled with the Numerical Propulsion System Simulation (NPSS) code. The mean line compressor flow analysis code with ice crystal modeling was utilized to estimate the parameters that indicate the risk of accretion, as well as to estimate the degree of blockage and losses caused by accretion during a full engine roll back point. The analysis provided additional validation of the icing risk parameters within the LPC, as well as the creation of models for

  3. Virtual instrumentation: a new approach for control and instrumentation - application in containment studies facility

    International Nuclear Information System (INIS)

    Gole, N.V.; Shanware, V.M.; Sebastian, A.; Subramaniam, K.

    2001-01-01

    PC based data-acquisition has emerged as a rapidly developing area particularly with respect to process instrumentation. Computer based data acquisition in process instrumentation combined with Supervisory Control and Data Acquisition (SCADA) software has introduced extensive possibilities with respect to formats for presentation of information. The concept of presenting data using any instrument format with the help of software tools to simulate the instrument on screen, needs to be understood, in order to be able to make use of its vast potential. The purpose of this paper is to present the significant features of the Virtual Instrumentation concept and discuss its application in the instrumentation and control system of containment studies facility (CSF). Factors involved in the development of the virtual instrumentation based I and C system for CSF are detailed and a functional overview of the system configuration is given. (author)

  4. LOFT instrumentation

    International Nuclear Information System (INIS)

    Bixby, W.W.

    1979-01-01

    A description of instrumentation used in the Loss-of-Fluid Test (LOFT) large break Loss-of-Coolant Experiments is presented. Emphasis is placed on hydraulic and thermal measurements in the primary system piping and components, reactor vessel, and pressure suppression system. In addition, instrumentation which is being considered for measurement of phenomena during future small break testing is discussed. (orig.) 891 HP/orig. 892 BRE [de

  5. Instrumentation for environmental monitoring: biomedical

    International Nuclear Information System (INIS)

    1979-05-01

    An update is presented to Volume four of the six-volume series devoted to a survey of instruments useful for measurements in biomedicine related to environmental research and monitoring. Results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Methods of detection and analysis of gaseous organic pollutants and metals, including Ni and As are presented. Instrument techniques and notes are included on atomic spectrometry and uv and visible absorption instrumentation

  6. Testing of Track Point Resolution of Gas Electron Multiplier with Pion Beam at CERN SPS

    CERN Document Server

    Adak, R P; Das, S; Dubey, A K; Ganti, M S; Saini, J; Singaraju, R

    2015-01-01

    A muon detection system using segmented and instrumented absorber has been designed for high-energy heavy-ion collision experiments to be held at GSI, Darmstadt, Germany. The muon detector system is mounted downstream of a Silicon Tracking System. The reconstructed tracks from the STS are to be matched to the hits in the GEM detector. For reconstructing track in the GEM Detector, track point resolution is an important issue. We report her first time the track point resolution of the GEM detector.

  7. Ageing studies on materials, components and process instruments used in nuclear power plants

    International Nuclear Information System (INIS)

    Bora, J.S.

    1997-04-01

    This report is a compilation of test results of thermal and radiation ageing tests carried out in the laboratory over a period of 25 years on diverse engineering materials, components and instruments used in nuclear power plants. Test items covered are different types of electrical cables, elastomers, surface coatings, electrical and electronics components and process instruments. Effects of thermal and radiation ageing on performance parameters are shown in tabular forms. Apart from finding the characteristics, capabilities and limitations of test items, ageing research has helped in pin-pointing sub-standard and critical parts and necessary corrective action has been taken. This report is expected to be quite useful to the manufacturers users and researchers for reference and guidance. (author)

  8. Temperature buffer test. Installation of buffer, heaters and instruments in the deposition hole

    Energy Technology Data Exchange (ETDEWEB)

    Johannesson, Lars-Erik; Sanden, Torbjoern; Aakesson, Mattias [Clay Technology AB, Lund (Sweden); Barcena, Ignacio; Garcia-Sineriz, Jose Luis [Aitemin, Madrid (Spain)

    2010-12-15

    During 2003 the Temperature Buffer Test was installed in Aespoe Hard Rock Laboratory. Temperature, water pressure, relative humidity, total pressure and displacements etc. are measured in numerous points in the test. Most of the cables from the transducers are led in the deposition hole through slots in the rock surface of the deposition hole in watertight tubes to the data collection system in a container placed in the tunnel close to the deposition hole. This report describes the work with the installations of the buffer, heaters, and instruments and yields a description of the final location of all instruments. The report also contains a description of the materials that were installed and the densities yielded after placement.

  9. Temperature buffer test. Installation of buffer, heaters and instruments in the deposition hole

    International Nuclear Information System (INIS)

    Johannesson, Lars-Erik; Sanden, Torbjoern; Aakesson, Mattias; Barcena, Ignacio; Garcia-Sineriz, Jose Luis

    2010-12-01

    During 2003 the Temperature Buffer Test was installed in Aespoe Hard Rock Laboratory. Temperature, water pressure, relative humidity, total pressure and displacements etc. are measured in numerous points in the test. Most of the cables from the transducers are led in the deposition hole through slots in the rock surface of the deposition hole in watertight tubes to the data collection system in a container placed in the tunnel close to the deposition hole. This report describes the work with the installations of the buffer, heaters, and instruments and yields a description of the final location of all instruments. The report also contains a description of the materials that were installed and the densities yielded after placement

  10. Aeroacoustics of Musical Instruments

    NARCIS (Netherlands)

    Fabre, B.; Gilbert, J.; Hirschberg, Abraham; Pelorson, X.

    2012-01-01

    We are interested in the quality of sound produced by musical instruments and their playability. In wind instruments, a hydrodynamic source of sound is coupled to an acoustic resonator. Linear acoustics can predict the pitch of an instrument. This can significantly reduce the trial-and-error process

  11. Effect of target color and scanning geometry on terrestrial LiDAR point-cloud noise and plane fitting

    Science.gov (United States)

    Bolkas, Dimitrios; Martinez, Aaron

    2018-01-01

    Point-cloud coordinate information derived from terrestrial Light Detection And Ranging (LiDAR) is important for several applications in surveying and civil engineering. Plane fitting and segmentation of target-surfaces is an important step in several applications such as in the monitoring of structures. Reliable parametric modeling and segmentation relies on the underlying quality of the point-cloud. Therefore, understanding how point-cloud errors affect fitting of planes and segmentation is important. Point-cloud intensity, which accompanies the point-cloud data, often goes hand-in-hand with point-cloud noise. This study uses industrial particle boards painted with eight different colors (black, white, grey, red, green, blue, brown, and yellow) and two different sheens (flat and semi-gloss) to explore how noise and plane residuals vary with scanning geometry (i.e., distance and incidence angle) and target-color. Results show that darker colors, such as black and brown, can produce point clouds that are several times noisier than bright targets, such as white. In addition, semi-gloss targets manage to reduce noise in dark targets by about 2-3 times. The study of plane residuals with scanning geometry reveals that, in many of the cases tested, residuals decrease with increasing incidence angles, which can assist in understanding the distribution of plane residuals in a dataset. Finally, a scheme is developed to derive survey guidelines based on the data collected in this experiment. Three examples demonstrate that users should consider instrument specification, required precision of plane residuals, required point-spacing, target-color, and target-sheen, when selecting scanning locations. Outcomes of this study can aid users to select appropriate instrumentation and improve planning of terrestrial LiDAR data-acquisition.

  12. Isotope-equipped measuring instruments

    International Nuclear Information System (INIS)

    Miyagawa, Kazuo; Amano, Hiroshi

    1980-01-01

    In the steel industry, though the investment in isotope-equipped measuring instruments is small as compared with that in machinery, they play important role in the moisture measurement in sintering and blast furnaces, the thickness measurement in rolling process and others in automatic control systems. The economic aspect of the isotope-equipped measuring instruments is described on the basis of the practices in Kimitsu Works of Nippon Steel Corporation: distribution of such instruments, evaluation of economic effects, usefulness evaluation in view of raising the accuracy, and usefulness evaluation viewed from the failure of the isotope instruments. The evaluation of economic effects was made under the premise that the isotope-equipped measuring instruments are not employed. Then, the effects of raising the accuracy are evaluated for a γ-ray plate thickness gauge and a neutron moisture gauge for coke in a blast furnace. Finally, the usefulness was evaluated, assuming possible failure of the isotope-equipped measuring instruments. (J.P.N.)

  13. The Focal Plane Assembly for the Athena X-Ray Integral Field Unit Instrument

    Science.gov (United States)

    Jackson, B. D.; Van Weers, H.; van der Kuur, J.; den Hartog, R.; Akamatsu, H.; Argan, A.; Bandler, S. R.; Barbera, M.; Barret, D.; Bruijn, M. P.; hide

    2016-01-01

    This paper summarizes a preliminary design concept for the focal plane assembly of the X-ray Integral Field Unit on the Athena spacecraft, an imaging microcalorimeter that will enable high spectral resolution imaging and point-source spectroscopy. The instrument's sensor array will be a 3840-pixel transition edge sensor (TES) microcalorimeter array, with a frequency domain multiplexed SQUID readout system allowing this large-format sensor array to be operated within the thermal constraints of the instrument's cryogenic system. A second TES detector will be operated in close proximity to the sensor array to detect cosmic rays and secondary particles passing through the sensor array for off-line coincidence detection to identify and reject events caused by the in-orbit high-energy particle background. The detectors, operating at 55 mK, or less, will be thermally isolated from the instrument cryostat's 2 K stage, while shielding and filtering within the FPA will allow the instrument's sensitive sensor array to be operated in the expected environment during both on-ground testing and in-flight operation, including stray light from the cryostat environment, low-energy photons entering through the X-ray aperture, low-frequency magnetic fields, and high-frequency electric fields.

  14. The instrumentation of the prestressed concrete vessel with hot liner at Seibersdorf Research Centre

    International Nuclear Information System (INIS)

    Zemann, H.

    1975-11-01

    The joint project ''Prestressed Concrete Pressure Vessel with Hot Liner'' at Seibersdorf Research Centre now is in the process of testing the PCPV both in construction and operation from the safety point of view. The physical state of the PCPV (modulus of elasticity, humidity of concrete, creeping, etc.) is brought to stable conditions by ''pre-aging''. In order to control this process of stabilisation, an extensive knowledge of the concrete and an elaborated instrumentation is a necessity. This paper presents a survey about the philosophy and the realisation of the instrumentation of the PCPV and the investigations we performed to interpret the measurements. (author)

  15. Instrumentation reference book

    CERN Document Server

    Boyes, Walt

    2002-01-01

    Instrumentation is not a clearly defined subject, having a 'fuzzy' boundary with a number of other disciplines. Often categorized as either 'techniques' or 'applications' this book addresses the various applications that may be needed with reference to the practical techniques that are available for the instrumentation or measurement of a specific physical quantity or quality. This makes it of direct interest to anyone working in the process, control and instrumentation fields where these measurements are essential.* Comprehensive and authoritative collection of technical information* Writte

  16. Jones' instrument technology

    CERN Document Server

    Jones, Ernest Beachcroft; Kingham, Edward G; Radnai, Rudolf

    1985-01-01

    Jones' Instrument Technology, Volume 5: Automatic Instruments and Measuring Systems deals with general trends in automatic instruments and measuring systems. Specific examples are provided to illustrate the principles of such devices. A brief review of a considerable number of standards is undertaken, with emphasis on the IEC625 Interface System. Other relevant standards are reviewed, including the interface and backplane bus standards. This volume is comprised of seven chapters and begins with a short introduction to the principles of automatic measurements, classification of measuring system

  17. A mathematical model for describing the mechanical behaviour of root canal instruments.

    Science.gov (United States)

    Zhang, E W; Cheung, G S P; Zheng, Y F

    2011-01-01

    The purpose of this study was to establish a general mathematical model for describing the mechanical behaviour of root canal instruments by combining a theoretical analytical approach with a numerical finite-element method. Mathematical formulas representing the longitudinal (taper, helical angle and pitch) and cross-sectional configurations and area, the bending and torsional inertia, the curvature of the boundary point and the (geometry of) loading condition were derived. Torsional and bending stresses and the resultant deformation were expressed mathematically as a function of these geometric parameters, modulus of elasticity of the material and the applied load. As illustrations, three brands of NiTi endodontic files of different cross-sectional configurations (ProTaper, Hero 642, and Mani NRT) were analysed under pure torsion and pure bending situation by entering the model into a finite-element analysis package (ANSYS). Numerical results confirmed that mathematical models were a feasible method to analyse the mechanical properties and predict the stress and deformation for root canal instruments during root canal preparation. Mathematical and numerical model can be a suitable way to examine mechanical behaviours as a criterion of the instrument design and to predict the stress and strain experienced by the endodontic instruments during root canal preparation. © 2010 International Endodontic Journal.

  18. Preliminary Results From a Heavily Instrumented Engine Ice Crystal Icing Test in a Ground Based Altitude Test Facility

    Science.gov (United States)

    Flegel, Ashlie B.; Oliver, Michael J.

    2016-01-01

    Preliminary results from the heavily instrumented ALF502R-5 engine test conducted in the NASA Glenn Research Center Propulsion Systems Laboratory are discussed. The effects of ice crystal icing on a full scale engine is examined and documented. This same model engine, serial number LF01, was used during the inaugural icing test in the Propulsion Systems Laboratory facility. The uncommanded reduction of thrust (rollback) events experienced by this engine in flight were simulated in the facility. Limited instrumentation was used to detect icing on the LF01 engine. Metal temperatures on the exit guide vanes and outer shroud and the load measurement were the only indicators of ice formation. The current study features a similar engine, serial number LF11, which is instrumented to characterize the cloud entering the engine, detect/characterize ice accretion, and visualize the ice accretion in the region of interest. Data were acquired at key LF01 test points and additional points that explored: icing threshold regions, low altitude, high altitude, spinner heat effects, and the influence of varying the facility and engine parameters. For each condition of interest, data were obtained from some selected variations of ice particle median volumetric diameter, total water content, fan speed, and ambient temperature. For several cases the NASA in-house engine icing risk assessment code was used to find conditions that would lead to a rollback event. This study further helped NASA develop necessary icing diagnostic instrumentation, expand the capabilities of the Propulsion Systems Laboratory, and generate a dataset that will be used to develop and validate in-house icing prediction and risk mitigation computational tools. The ice accretion on the outer shroud region was acquired by internal video cameras. The heavily instrumented engine showed good repeatability of icing responses when compared to the key LF01 test points and during day-to-day operation. Other noticeable

  19. Environmental policy and economic efficiency: tradable permits versus regulatory instrument to control air pollution: a comparative approach USA/France

    International Nuclear Information System (INIS)

    Cros, Ch.

    1998-12-01

    The key issue of the thesis paradox of the weak implementation of economic instruments whereas 1) they are theoretically and also empirically considered as efficient; 2) the market imposes itself as the central reference to modem economies; and 3) economic efficiency is nowadays a legitimacy measure of public policies. Two different answers can be given: either theoretical analysis does not enable to explain the real economic efficiency of a political instrument, or environmental policies do not have economic efficiency as their main objective. The analysis take place in a context of a limited rationality and an inter-temporal consistency of public policies. The purpose is to understand the role of economic efficiency criteria during the adoption, building, and evolution of an environmental policy with an analytical point of view, and not a normative one. The institutional analysis of the American and the French pollution control policies, representative of the implementation of a trading permit system for the first, and of a regulatory instrument for the second, prove that the theoretical analysis of an instrument can not explain a real coordination, but only one organizational form among others. An institutional trajectory is the interpretation of policy instruments of policy instruments from 5 fundamental elements: the nature of the legitimacy of the policy; the nature of the regulator hypothesis on the information; the nature of the decision-making basis; the nature of the collective action. A coordination changes when the occurrence of an event moves one of the fundamental elements, and disorganizes the satisfying equilibrium of the agents. Then, the economic efficiency becomes a negotiation point. A political instrument is adopted for its own ability to solve a dysfunction without disrupting the coordination. (author)

  20. Astronomical Instrumentation System Markup Language

    Science.gov (United States)

    Goldbaum, Jesse M.

    2016-05-01

    The Astronomical Instrumentation System Markup Language (AISML) is an Extensible Markup Language (XML) based file format for maintaining and exchanging information about astronomical instrumentation. The factors behind the need for an AISML are first discussed followed by the reasons why XML was chosen as the format. Next it's shown how XML also provides the framework for a more precise definition of an astronomical instrument and how these instruments can be combined to form an Astronomical Instrumentation System (AIS). AISML files for several instruments as well as one for a sample AIS are provided. The files demonstrate how AISML can be utilized for various tasks from web page generation and programming interface to instrument maintenance and quality management. The advantages of widespread adoption of AISML are discussed.

  1. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1981-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities, as well as from old waste-burial-ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. The assay instrumentation that is applied specifically to soil monitoring is discussed

  2. Instruments to assess integrated care

    DEFF Research Database (Denmark)

    Lyngsø, Anne Marie; Godtfredsen, Nina Skavlan; Høst, Dorte

    2014-01-01

    INTRODUCTION: Although several measurement instruments have been developed to measure the level of integrated health care delivery, no standardised, validated instrument exists covering all aspects of integrated care. The purpose of this review is to identify the instruments concerning how to mea...... was prevalent. It is uncertain whether development of a single 'all-inclusive' model for assessing integrated care is desirable. We emphasise the continuing need for validated instruments embedded in theoretical contexts.......INTRODUCTION: Although several measurement instruments have been developed to measure the level of integrated health care delivery, no standardised, validated instrument exists covering all aspects of integrated care. The purpose of this review is to identify the instruments concerning how...... to measure the level of integration across health-care sectors and to assess and evaluate the organisational elements within the instruments identified. METHODS: An extensive, systematic literature review in PubMed, CINAHL, PsycINFO, Cochrane Library, Web of Science for the years 1980-2011. Selected...

  3. Analysis on detection accuracy of binocular photoelectric instrument optical axis parallelism digital calibration instrument

    Science.gov (United States)

    Ying, Jia-ju; Yin, Jian-ling; Wu, Dong-sheng; Liu, Jie; Chen, Yu-dan

    2017-11-01

    Low-light level night vision device and thermal infrared imaging binocular photoelectric instrument are used widely. The maladjustment of binocular instrument ocular axises parallelism will cause the observer the symptom such as dizziness, nausea, when use for a long time. Binocular photoelectric equipment digital calibration instrument is developed for detecting ocular axises parallelism. And the quantitative value of optical axis deviation can be quantitatively measured. As a testing instrument, the precision must be much higher than the standard of test instrument. Analyzes the factors that influence the accuracy of detection. Factors exist in each testing process link which affect the precision of the detecting instrument. They can be divided into two categories, one category is factors which directly affect the position of reticle image, the other category is factors which affect the calculation the center of reticle image. And the Synthesize error is calculated out. And further distribute the errors reasonably to ensure the accuracy of calibration instruments.

  4. Performance Monitoring for Nuclear Safety Related Instrumentation at PUSPATI TRIGA Reactor (RTP)

    International Nuclear Information System (INIS)

    Zareen Khan Abdul Jalil Khan; Ridzuan Abdul Mutalib; Mohd Sabri Minhat

    2015-01-01

    The Reactor TRIGA PUSPATI (RTP) at Malaysia Nuclear Agency is a TRIGA Mark II type reactor and pool type cooled by natural circulation of light water. This paper describe on performance monitoring for nuclear safety related instrumentation in TRIGA PUSPATI Reactor (RTP) of based on various parameter of reactor safety instrument channel such as log power, linear power, Fuel temperature, coolant temperature will take into consideration. Methodology of performance on estimation and monitoring is to evaluate and analysis of reactor parameters which is important of reactor safety and control. And also to estimate power measurement, differential of log and linear power and fuel temperature during reactor start-up, operation and shutdown .This study also focus on neutron power fluctuation from fission chamber during reactor start-up and operation. This work will present result of performance monitoring from RTP which indicated the safety parameter identification and initiate safety action on crossing the threshold set point trip. Conclude that performance of nuclear safety related instrumentation will improved the reactor control and safety parameter during reactor start-up, operation and shutdown. (author)

  5. Resolution of point sources of light as analyzed by quantum detection theory.

    Science.gov (United States)

    Helstrom, C. W.

    1973-01-01

    The resolvability of point sources of incoherent thermal light is analyzed by quantum detection theory in terms of two hypothesis-testing problems. In the first, the observer must decide whether there are two sources of equal radiant power at given locations, or whether there is only one source of twice the power located midway between them. In the second problem, either one, but not both, of two point sources is radiating, and the observer must decide which it is. The decisions are based on optimum processing of the electromagnetic field at the aperture of an optical instrument. In both problems the density operators of the field under the two hypotheses do not commute. The error probabilities, determined as functions of the separation of the points and the mean number of received photons, characterize the ultimate resolvability of the sources.

  6. The Inner Magnetospheric Imager (IMI): Instrument heritage and orbit viewing analysis

    Science.gov (United States)

    Wilson, Gordon R.

    1992-12-01

    For the last two years an engineering team in the Program Development Office at MSFC has been doing design studies for the proposed Inner Magnetospheric Imager (IMI) mission. This team had a need for more information about the instruments that this mission would carry so that they could get a better handle on instrument volume, mass, power, and telemetry needs as well as information to help assess the possible cost of such instruments and what technology development they would need. To get this information, an extensive literature search was conducted as well as interviews with several members of the IMI science working group. The results of this heritage survey are summarized below. There was also a need to evaluate the orbits proposed for this mission from the stand point of their suitability for viewing the various magnetospheric features that are planned for this mission. This was accomplished by first, identifying the factors which need to be considered in selecting an orbit, second, translating these considerations into specific criteria, and third, evaluating the proposed orbits against these criteria. The specifics of these criteria and the results of the orbit analysis are contained in the last section of this report.

  7. How Effective Are Non-monetary Instruments for Safe Driving? Panel Data Evidence on the Effect of the Demerit Point System in Denmark

    DEFF Research Database (Denmark)

    Abay, Kibrom Araya

    2017-01-01

    to each demerit point assigned to their driving license. We also find that drivers’ effort, and hence response, increases with the number of demerit points accumulated. Depending on the number of demerit points accumulated, drivers with one or more demerit points reduced their frequency of traffic...

  8. Assessment of the measurement properties of the post stroke motor function instruments available in Brazil: a systematic review.

    Science.gov (United States)

    Lima, Elaine; Teixeira-Salmela, Luci F; Simões, Luan; Guerra, Ana C C; Lemos, Andrea

    2016-03-15

    While there are several instruments in Brazil that measure motor function in patients after stroke, it is unknown whether the measurement properties of these instruments are appropriate. To identify the motor function instruments available in Brazil for patients after stroke. To assess the methodological quality of the studies and the results related to the measurement properties of these instruments. Two independent reviewers conducted searches on PubMed, LILACS, CINAHL, Web of Science, and Scopus. Studies that aimed to cross-culturally adapt an existing instrument or create a Brazilian instrument and test at least one measurement property related to motor function in patients after stroke were included. The methodological quality of these studies was checked by the COSMIN checklist with 4-point rating scale and the results of the measurement properties were analyzed by the criteria developed by Terwee et al. A total of 11 instruments were considered eligible, none of which were created in Brazil. The process of cross-cultural adaptation was inadequate in 10 out of 11 instruments due to the lack of back-translation or due to inappropriate target population. All of the instruments presented flaws in the measurement properties, especially reliability, internal consistency, and construct validity. The flaws observed in both cross-cultural adaptation process and testing measurement properties make the results inconclusive on the validity of the available instruments. Adequate procedures of cross-cultural adaptation and measurement properties of these instruments are strongly needed.

  9. Assessment of the measurement properties of the post stroke motor function instruments available in Brazil: a systematic review

    Directory of Open Access Journals (Sweden)

    Elaine Lima

    2016-01-01

    Full Text Available Background While there are several instruments in Brazil that measure motor function in patients after stroke, it is unknown whether the measurement properties of these instruments are appropriate. Objective To identify the motor function instruments available in Brazil for patients after stroke. To assess the methodological quality of the studies and the results related to the measurement properties of these instruments. Method Two independent reviewers conducted searches on PubMed, LILACS, CINAHL, Web of Science, and Scopus. Studies that aimed to cross-culturally adapt an existing instrument or create a Brazilian instrument and test at least one measurement property related to motor function in patients after stroke were included. The methodological quality of these studies was checked by the COSMIN checklist with 4-point rating scale and the results of the measurement properties were analyzed by the criteria developed by Terwee et al. Results A total of 11 instruments were considered eligible, none of which were created in Brazil. The process of cross-cultural adaptation was inadequate in 10 out of 11 instruments due to the lack of back-translation or due to inappropriate target population. All of the instruments presented flaws in the measurement properties, especially reliability, internal consistency, and construct validity. Conclusion The flaws observed in both cross-cultural adaptation process and testing measurement properties make the results inconclusive on the validity of the available instruments. Adequate procedures of cross-cultural adaptation and measurement properties of these instruments are strongly needed.

  10. The "Palliative Care Quality of Life Instrument (PQLI" in terminal cancer patients

    Directory of Open Access Journals (Sweden)

    Kouvaris John

    2004-02-01

    Full Text Available Abstract Background This paper describes the development of a new quality of life instrument in advanced cancer patients receiving palliative care. Methods The Palliative Care Quality of Life Instrument incorporates six multi-item and one single-item scale. The questionnaire was completed at baseline and one-week after. The final sample consisted of 120 patients. Results The average time required to complete the questionnaire, in both time points, was approximately 8 minutes. All multi-item scales met the minimal standards for reliability (Cronbach's alpha coefficient ≥.70 either before or during palliative treatment. Test-retest reliability in terms of Spearman-rho coefficient was also satisfactory (p Conclusion The PQLI is a reliable and valid measure for the assessment of quality of life in patients with advanced stage cancer.

  11. [Controlling instruments in radiology].

    Science.gov (United States)

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  12. Spectrography analysis of stainless steel by the point to point technique

    International Nuclear Information System (INIS)

    Bona, A.

    1986-01-01

    A method for the determination of the elements Ni, Cr, Mn, Si, Mo, Nb, Cu, Co and V in stainless steel by emission spectrographic analysis using high voltage spark sources is presented. The 'point-to-point' technique is employed. The experimental parameters were optimized taking account a compromise between the detection sensitivity and the precision of the measurement. The parameters investigated were the high voltage capacitance, the inductance, the analytical and auxiliary gaps, the period of pre burn spark and the time of exposure. The edge shape of the counter electrodes and the type of polishing and diameter variation of the stailess steel eletrodes were evaluated in preliminary assays. In addition the degradation of the chemical power of the developer was also investigated. Counter electrodes of graphite, copper, aluminium and iron were employed and the counter electrode itself was used as an internal standard. In the case of graphite counter electrodes the iron lines were employed as internal standard. The relative errors were the criteria for evaluation of these experiments. The National Bureau of Standards - Certified reference stainless steel standards and the Eletrometal Acos Finos S.A. samples (certified by the supplier) were employed for drawing in the calibration systems and analytical curves. The best results were obtained using the convencional graphite counter electrodes. The inaccuracy and the imprecision of the proposed method varied from 2% to 15% and from 1% to 9% respectively. This present technique was compared to others instrumental techniques such as inductively coupled plasma, X-ray fluorescence and neutron activation analysis. The advantages and disadvantages for each case were discussed. (author) [pt

  13. Analysis of instrumentation technology for SMART

    International Nuclear Information System (INIS)

    Hur, Seop; Koo, I. S.; Park, H. Y.; Lee, C. K.; Kim, D. H.; Suh, Y. S.; Seong, S. H.; Jang, G. S.

    1998-03-01

    It is necessary that development requirements, techniques to be developed, and development tasks and approach are established to develop the SMART instrumentation system. It is important to establish the development strategies for input for developing SMART instrumentation system. To meet above needs, the industry general and nuclear instrumentation techniques were analyzed and reviewed, respectively, based on the classification of instrumentation to analyze the industrial instrumentation techniques, and analysis results which described the inherent merits and demerits of each technique can be used for inputs to select the instruments for SMART. For the instrumentation techniques for nuclear environments, the major instrumentation techniques were reviewed, and the instrumentation system were established. The following development approaches were established based on the development requirements and the analysis results of research and development trends of industrial and nuclear instrumentation techniques. (author). 90 refs., 38 tabs., 33 figs

  14. Software System for the Calibration of X-Ray Measuring Instruments

    International Nuclear Information System (INIS)

    Gaytan-Gallardo, E.; Tovar-Munoz, V. M.; Cruz-Estrada, P.; Vergara-Martinez, F. J.; Rivero-Gutierrez, T.

    2006-01-01

    A software system that facilities the calibration of X-ray measuring instruments used in medical applications is presented. The Secondary Standard Dosimetry Laboratory (SSDL) of the Nuclear Research National Institute in Mexico (ININ in Spanish), supports activities concerning with ionizing radiations in medical area. One of these activities is the calibration of X-ray measuring instruments, in terms of air kerma or exposure by substitution method in an X-ray beam at a point where the rate has been determined by means of a standard ionization chamber. To automatize this process, a software system has been developed, the calibration system is composed by an X-ray unit, a Dynalizer IIIU X-ray meter by RADCAL, a commercial data acquisition card, the software system and the units to be tested and calibrated. A quality control plan has been applied in the development of the software system, ensuring that quality assurance procedures and standards are being followed

  15. An Attitude Scale on Individual Instrument and Individual Instrument Course: Validity-Reliability Research

    Science.gov (United States)

    Kuçukosmanoglu, Hayrettin Onur

    2015-01-01

    The main purpose of this study is to develop a scale to determine students' attitude levels on individual instruments and individual instrument courses in instrument training, which is an important dimension of music education, and to conduct a validity-reliability research of the scale that has been developed. The scale consists of 16 items. The…

  16. Comparing Single-Point and Multi-point Calibration Methods in Modulated DSC

    Energy Technology Data Exchange (ETDEWEB)

    Van Buskirk, Caleb Griffith [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-14

    Heat capacity measurements for High Density Polyethylene (HDPE) and Ultra-high Molecular Weight Polyethylene (UHMWPE) were performed using Modulated Differential Scanning Calorimetry (mDSC) over a wide temperature range, -70 to 115 °C, with a TA Instruments Q2000 mDSC. The default calibration method for this instrument involves measuring the heat capacity of a sapphire standard at a single temperature near the middle of the temperature range of interest. However, this method often fails for temperature ranges that exceed a 50 °C interval, likely because of drift or non-linearity in the instrument's heat capacity readings over time or over the temperature range. Therefore, in this study a method was developed to calibrate the instrument using multiple temperatures and the same sapphire standard.

  17. Outcome of instrumented spinal fusion for chronic low back pain: review of 100 patients

    International Nuclear Information System (INIS)

    Qureshi, M.A; Pasha, I.F.; Malik, A.S.; Asad, A.; Aebi, M.

    2010-01-01

    Objective of this study was to evaluate the outcome of instrumented spinal fusion in selected patients with Chronic Low Back Pain (CLBP) in our setup. Consecutive first one hundred patients were selected from spine unit database that underwent instrumented spinal fusion for chronic low back pain lasting more than one year, due to degenerative disease of spine. Average age was 42 years. There were 62 males and 38 females. Diagnosis included; spinal stenosis (26%), failed disc surgery (22%), spondylolisthesis (19%), degenerative disc disease (17%), and instability (16%). Operations performed; Pedicle Screw Fixation (PSF) with Postero-lateral Fusion (PLF) in 3% patients. Trans Laminar Facet Screw (TLFS) with PLF in 24% patients. Anterior Lumbar Inter-body Fusion (ALIF) in 9% patients. Posterior Lumbar Inter-body Fusion (PLIF) in 40% patients and Trans-foraminal Lumbar Inter-body Fusion (TLIF) in 24% patients. Average follow up was for 30 months. 86% patients had full spinal fusion. 71% patients were fully satisfied with treatment, 28% were partially satisfied. Post-operatively, on average, visual analogue scale (VAS) showed 48 points significant improvement and Oswestry Disability Index (ODI) showed 53 points significant improvement. Instrumented Spinal Fusion is effective in our set up for relieving symptoms and improving functional outcome in selected patients with debilitating Chronic Low Back Pain due to degenerative disease of spine. Single fusion technique is not ideal for all types of patients and surgeon has to be versatile and trained in using different fusion techniques as the situation demands. (author)

  18. Solar Array Disturbances to Spacecraft Pointing During the Lunar Reconnaissance Orbiter (LRO) Mission

    Science.gov (United States)

    Calhoun, Philip

    2010-01-01

    The Lunar Reconnaissance Orbiter (LRO), the first spacecraft to support NASA s return to the Moon, launched on June 18, 2009 from the Cape Canaveral Air Force Station aboard an Atlas V launch vehicle. It was initially inserted into a direct trans-lunar trajectory to the Moon. After a five day transit to the Moon, LRO was inserted into the Lunar orbit and successfully lowered to a low altitude elliptical polar orbit for spacecraft commissioning. Successful commissioning was completed in October 2009 when LRO was placed in its near circular mission orbit with an approximate altitude of 50km. LRO will spend at least one year orbiting the Moon, collecting lunar environment science and mapping data, utilizing a suite of seven instruments to enable future human exploration. The objective is to provide key science data necessary to facilitate human return to the Moon as well as identification of opportunities for future science missions. LRO's instrument suite will provide the high resolution imaging data with sub-meter accuracy, highly accurate lunar cartographic maps, mineralogy mapping, amongst other science data of interest. LRO employs a 3-axis stabilized attitude control system (ACS) whose primary control mode, the "Observing Mode", provides Lunar nadir, off-nadir, and inertial fine pointing for the science data collection and instrument calibration. This controller combines the capability of fine pointing with on-demand large angle full-sky attitude reorientation. It provides simplicity of spacecraft operation as well as additional flexibility for science data collection. A conventional suite of ACS components is employed in the Observing Mode to meet the pointing and control objectives. Actuation is provided by a set of four reaction wheels developed in-house at NASA Goddard Space Flight Center (GSFC). Attitude feedback is provided by a six state Kalman filter which utilizes two SELEX Galileo Star Trackers for attitude updates, and a single Honeywell Miniature

  19. Applications of optical links to the protective instrumentation of nuclear power stations and to stabilisation of scintillation detectors

    International Nuclear Information System (INIS)

    Breuze, G.

    1979-01-01

    The description is given of a system of transmission by optical fibre opto-electronic links capable of carrying out many point by point transmissions of logical signals: between acquisition and protection processing units, between acquisition and protection processing units and the control room, between acquisition and protection processing units and logical safety units, and between logical safety units and control room. A short description is also given of an optical fibre signal transmission system constituting a new instrumentation for stabilising spectra coming from NaI (Tl) scintillation detectors. In addition to the remote control of the detectors such an instrumentation is capable of improving the stability performance of gamma ray cameras (a beam of monofibres is then necessary) as well as that of any detector placed in an inaccessible or hostile environment (fuel reprocessing plant, for example) [fr

  20. Near instrument-free, simple molecular device for rapid detection of herpes simplex viruses.

    Science.gov (United States)

    Lemieux, Bertrand; Li, Ying; Kong, Huimin; Tang, Yi-Wei

    2012-06-01

    The first near instrument-free, inexpensive and simple molecular diagnostic device (IsoAmp HSV, BioHelix Corp., MA, USA) recently received US FDA clearance for use in the detection of herpes simplex viruses (HSV) in genital and oral lesion specimens. The IsoAmp HSV assay uses isothermal helicase-dependent amplification in combination with a disposable, hermetically-sealed, vertical-flow strip identification. The IsoAmp HSV assay has a total test-to-result time of less than 1.5 h by omitting the time-consuming nucleic acid extraction. The diagnostic sensitivity and specificity are comparable to PCR and are superior to culture-based methods. The near instrument-free, rapid and simple characteristics of the IsoAmp HSV assay make it potentially suitable for point-of-care testing.

  1. Power station instrumentation

    International Nuclear Information System (INIS)

    Jervis, M.W.

    1993-01-01

    Power stations are characterized by a wide variety of mechanical and electrical plant operating with structures, liquids and gases working at high pressures and temperatures and with large mass flows. The voltages and currents are also the highest that occur in most industries. In order to achieve maximum economy, the plant is operated with relatively small margins from conditions that can cause rapid plant damage, safety implications, and very high financial penalties. In common with other process industries, power stations depend heavily on control and instrumentation. These systems have become particularly significant, in the cost-conscious privatized environment, for providing the means to implement the automation implicit in maintaining safety standards, improving generation efficiency and reducing operating manpower costs. This book is for professional instrumentation engineers who need to known about their use in power stations and power station engineers requiring information about the principles and choice of instrumentation available. There are 8 chapters; chapter 4 on instrumentation for nuclear steam supply systems is indexed separately. (Author)

  2. Multimode laser beam analyzer instrument using electrically programmable optics.

    Science.gov (United States)

    Marraccini, Philip J; Riza, Nabeel A

    2011-12-01

    Presented is a novel design of a multimode laser beam analyzer using a digital micromirror device (DMD) and an electronically controlled variable focus lens (ECVFL) that serve as the digital and analog agile optics, respectively. The proposed analyzer is a broadband laser characterization instrument that uses the agile optics to smartly direct light to the required point photodetectors to enable beam measurements of minimum beam waist size, minimum waist location, divergence, and the beam propagation parameter M(2). Experimental results successfully demonstrate these measurements for a 500 mW multimode test laser beam with a wavelength of 532 nm. The minimum beam waist, divergence, and M(2) experimental results for the test laser are found to be 257.61 μm, 2.103 mrad, 1.600 and 326.67 μm, 2.682 mrad, 2.587 for the vertical and horizontal directions, respectively. These measurements are compared to a traditional scan method and the results of the beam waist are found to be within error tolerance of the demonstrated instrument.

  3. Some emergency instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Burgess, P H

    1986-10-01

    The widespread release of activity and the resultant spread of contamination after the Chernobyl accident resulted in requests to NRPB to provide instruments for, and expertise in, the measurement of radiation. The most common request was for advice on the usefulness of existing instruments, but Board staff were also involved in their adaptation or in the development of new instruments specially to meet the circumstances of the accident. The accident occurred on 26 April. On 1 May, NRPB was involved at Heathrow Airport in the monitoring of the British students who had returned from Kiev and Minsk. The main purpose was to reassure the students by checking that their persons and belongings did not have significant surface contamination. Additional measurements were also made of iodine activity in thyroid using hand-held detectors or a mobile body monitor. This operation was arranged with the Foreign and Commonwealth Office, which had also received numerous requests for instruments from embassies and consulates in countries close to the scene of the accident. There was concern for the well-being of staff and other United Kingdom nationals who resided in or intended to visit the most affected countries. The board supplied suitable instruments, and the FCO distributed them to embassies. The frequency of environmental monitoring was increased from 29 April in anticipation of contamination and appropriate Board instrumentation was deployed. After the Chernobyl cloud arrived in the UK on 2 May, there were numerous requests from local government, public authorities, private companies and members of the public for information and advice on monitoring equipment and procedures. Some of these requirements could be met with existing equipment but members of the public were usually advised not to proceed. At a later stage, the contamination of foodstuffs and livestock required the development of an instrument capable of detecting low levels of {sup 137}Cs and {sup 134}Cs in food

  4. Validation of the Osteoporosis Smoking Health Belief instrument.

    Science.gov (United States)

    Doheny, Margaret O; Sedlak, Carol A; Zeller, Richard; Estok, Patricia J

    2010-01-01

    Smoking has a deleterious effect on bone mineral density. Psychometric properties were conducted for 3 smoking cessation subscales of the Osteoporosis Smoking Health Belief (OSHB) instrument: barriers, benefits, and self-efficacy. The instrument was evaluated by 6 nurse researchers, administered to a pilot sample of 23 adult smokers aged 19-39, and to a convenience sample of 59 adult smokers aged 19-84 years attending bingo at churches and community centers. Principal components factor analyses were conducted on the 18 items at both time points and accounted for 65.05% of the variances in the matrix at Time 1 and 71.19% at Time 2. The 3 statistical factors corresponded to the theoretically derived concepts. Cronbach's alphas for benefits of not smoking were .86 at Time 1 and .88 at Time 2; for barriers, .78 at Time 1 and .89 at Time 2; and for self-efficacy, .94 at Time 1 and .96 at Time 2. The test-retest correlations were .68 for benefits, .74 for barriers, and .79 for self-efficacy. Paired t tests showed no significant change over time. The OSHB meets relevant measurement criteria.

  5. Safeguarding on-power fuelled reactors - instrumentation and techniques

    International Nuclear Information System (INIS)

    Waligura, A.; Konnov, Y.; Smith, R.M.; Head, D.A.

    1977-05-01

    Instrumentation and techniques applicable to safeguarding reactors that are fuelled on-power, particularly the CANDU type, have been developed. A demonstration is being carried out at the Douglas Point Nuclear Generating Station in Canada. Irradiated nuclear materials in certain areas - the reactor and spent fuel storage bays - are monitored using photographic and television cameras, and seals. Item accounting is applied by counting spent-fuel bundles during transfer from the reactor to the storage bay and by placing these spent-fuel bundles in a sealed enclosure. Provision is made for inspection and verification of the bundles before sealing. The reactor's power history is recorded by a Track-Etch power monitor. Redundancy is provided so that the failure of any single piece of equipment does not invalidate the entire safeguards system. Several safeguards instruments and devices have been developed and evaluated. These include a super-8-mm surveillance camera system, a television surveillance system, a spent-fuel bundle counter, a device to detect dummy fuel bundles, a cover for enclosing a stack of spent-fuel bundles, and a seal suitable for underwater installation and ultrasonic interrogation. (author)

  6. The Science of String Instruments

    CERN Document Server

    Rossing, Thomas D

    2010-01-01

    Many performing musicians, as well as instrument builders, are coming to realize the importance of understanding the science of musical instruments. This book explains how string instruments produce sound. It presents basic ideas in simple language, and it also translates some more sophisticated ideas in non-technical language. It should be of interest to performers, researchers, and instrument makers alike.

  7. A perspectiva pragmática nas pesquisas sobre prática instrumental: condições e implicações procedimentais A pragmatic perspective in instrumental practice research: conditions and procedural implications

    Directory of Open Access Journals (Sweden)

    Regina Antunes Teixeira dos Santos

    2009-01-01

    Full Text Available Pesquisas em prática instrumental evidenciam tendências que expressam certos aspectos de racionalidade calculada da ação e apontam para uma perspectiva pragmática de engajamento pessoal frente às situações de prática. Sistematizações sobre modos intencionais de proceder na prática instrumental em conexão com níveis de especialização músico-instrumental encontram-se não somente nos resultados dessas pesquisas, mas também implícitos nos conceitos de prática. Assim, o presente artigo discute a natureza e a finalidade das condições procedimentais implícitas nos conceitos e resultados de pesquisas em prática instrumental. Implicações procedimentais apresentam-se também nas discussões referentes à quantidade e a qualidade na prática, e justificam a existência de níveis diferenciados de especialização músico-instrumental na prática. O presente artigo aborda ainda a relação entre procedimentos e estratégias de prática.Research in instrumental practice has shown some trends that express certain aspects of calculated rationality, and point out to a pragmatic regime of personal commitment during practice. The systematization of the intentional procedures of the performer in order to improve and to refine one's music expertise level is present in research as well as in the concepts of instrumental practice. Thus, the present article discusses the nature and the goals of the procedimental conditions implicit in the concepts and research results in instrumental practice. Procedimental implications are also present in the discussion of the role of quantity and quality in the practice and justify the existence of different levels of instrumental expertise in the practice. This article also raises the relationship between procedures and strategies of practice.

  8. Conceptual phase A design of a cryogenic shutter mechanism for the SAFARI flight instrument

    Science.gov (United States)

    Eigenmann, Max; Wehmeier, Udo J.; Vuilleumier, Aurèle; Messina, Gabriele; Meyer, Michael R.

    2012-09-01

    We present a conceptual design for a cryogenic optical mechanism for the SAFARI instrument. SAFARI is a long wavelength (34-210 micron) Imaging Fourier Transform Spectrometer (FTS) to fly as an ESA instrument on the JAXA SPICA mission projected to launch in 2021. SPICA is a large 3m class space telescope which will have an operating temperature of less than 7K. The SAFARI shutter is a single point of failure flight mechanism designed to operate in space at a temperature of 4K which meets redundancy and reliability requirements of this challenging mission. The conceptual design is part of a phase A study led by ETH Institute for Astronomy and conducted by RUAG Space AG.

  9. A Compact, Low Resource Instrument to Measure Atmospheric Methane and Carbon Dioxide From Orbit

    Science.gov (United States)

    Rafkin, Scot; Davis, Michael; Varner, Ruth; Basu, Sourish; Bruhwiler, Lori; Luspay-Kuti, Adrienn; Mandt, Kathy; Roming, Pete; Soto, Alejandro; Tapley, Mark

    2017-04-01

    -resource instrument that meets the accuracy and spatial resolution challenges demanded by methane exchange processes. The baseline instrument uses reflected sunlight 0.7591-0.7646 μm and 1.6058-1.6761 μm, permitting individual spectral identification of CH4, O2, CO2 and H2O. By combining spectral information, the complicating effects of aerosol and clouds can be reduced. A spectral resolving power of R˜20,000 is achieved by utilizing a novel matching off-axis parabolic (OAP) mirror system to send a collimated beam to an Echelle grating, which then picks off the high orders of interest and sends them back to one of the OAPs for final focus. A beamsplitter before the focus separates the near-visible O2 signal from the ˜1.6 μm CH4, CO2, and H2O signals, creating two separate imaging channels. A high-heritage H1RG detector is used in both channels. The instrument images a 0.03°× 5° field-of-view, with a point-source resolution of 0.03°. These specifications produce a 33 km wide instantaneous image at the nominal altitude of 380 km, with 200 m point-source resolution. Higher altitudes yield increased instantaneous coverage at the cost of wider point-source resolution. The 200 m pixels can be averaged to produce higher signal-to-noise while still maintaining km-scale resolution. The entire instrument consumes 55 W with a mass of 20 kg and total volume of 0.07 m3. Thus, the instrument provides performance similar to or better than existing hardware in a much smaller package. The small resource footprint provides the opportunity to fly as payload on one or multiple small satellite payloads or on the International Space Station.

  10. Instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-15

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  11. Instrumental analysis

    International Nuclear Information System (INIS)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-01

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  12. Recent developments in X-ray and neutron small-angle scattering instrumentation and data analysis

    International Nuclear Information System (INIS)

    Schelten, J.

    1978-01-01

    The developments in instrumentation and data analysis that have occurred in the field of small-angle X-ray and neutron scattering since 1973 are reviewed. For X-rays, the cone camera collimation was invented, synchrotrons and storage rings were demonstrated to be intense sources of X-radiation, and one- and two-dimensional position-sensitive detectors were interfaced to cameras with both point and line collimation. For neutrons, the collimators and detectors on the Juelich and Grenoble machines were improved, new D11-type instruments were built or are under construction at several sites, double-crystal instruments were set up, and various new machines have been proposed. Significant progress in data analysis and evaluation has been made through application of mathematical techniques such as the use of spline functions, error minimization with constraints, and linear programming. Several special experiments, unusual in respect to the anisotropy of the scattering pattern, gravitational effects, moving scatterers, and dynamic fast time slicing, are discussed. (Auth.)

  13. An evaluation of Brix refractometry instruments for measurement of colostrum quality in dairy cattle.

    Science.gov (United States)

    Bielmann, V; Gillan, J; Perkins, N R; Skidmore, A L; Godden, S; Leslie, K E

    2010-08-01

    Acquisition of high quality colostrum is an important factor influencing neonatal calf health. Many methods have been used to assess the Ig concentration of colostrum; however, improved, validated evaluation tools are needed. The aims of this study were to evaluate both optical and digital Brix refractometer instruments for the measurement of Ig concentration of colostrum as compared with the gold standard radial immunodiffusion assay laboratory assessment and to determine the correlation between Ig measurements taken from fresh and frozen colostrum samples for both Brix refractometer instruments. This research was completed using 288 colostrum samples from 3 different farms. It was concluded that the optical and digital Brix refractometers were highly correlated for both fresh and frozen samples (r=0.98 and r=0.97, respectively). Correlation between both refractometer instruments for fresh and frozen samples and the gold standard radial immunodiffusion assay were determined to be very similar, with a correlation coefficient between 0.71 and 0.74. Both instruments exhibited excellent test characteristics, indicating an appropriate cut-off point of 22% Brix score for the identification of good quality colostrum. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  14. Technical testing of portable isotope identification instruments

    International Nuclear Information System (INIS)

    Smith, D.E.

    2001-01-01

    Full text: The United States Customs Service has, as a part of its mission, the protection of the borders of the United States from the import or export of illicit radioactive materials. Of paramount importance is the ability to interdict the smuggling of special nuclear material, nuclear weapons and other radioactive materials that could be used as a weapon of mass destruction against the population and infrastructure of the U.S. or another country. Radiation detection technology exists in the form of pocket size, hand-held and portal radiation detectors that have the ability to detect radiation with great sensitivity and low false alarm rates. U.S. Customs has chosen to implement pocket size detectors or radiation pagers as the personal tool of each inspector for the detection of radioactive material. In the search for illicit shipment of radioactive materials, innocent radiation detections may occur with some frequency due to common radioactive sources that may be encountered in day to day living. Examples include lantern mantles, some camera lenses, welding rods, certain dishware containing uranium glaze, and natural marble objects such as statues or architectural pieces. Perhaps the most common innocent detection encountered at the border and in public areas in general is due to the in vivo placement of radioactive sources for use in nuclear medicine therapy and diagnostics. Outpatients from such therapy can remain detectable for three weeks or more. Also, legal shipments of radioisotopes are common occurrences in cargo and express mail shipments. The customs inspector who detects radioactive material in the course of his duties must decide whether detection is innocent; is indicative of a nuclear device or special nuclear material; or whether the source could be injurious to him/her or the general public. It is at this point that a portable instrument capable of identifying gamma or neutron emitting isotopes is essential to the customs examination procedure

  15. Cryogenic instrumentation with cold electronics-A review

    International Nuclear Information System (INIS)

    Rao, M.G.; Scurlock, R.G.

    1986-01-01

    The low level signals from cryogenic sensors and transducers are usually carried to the electronic signal conditioning and data handling systems at ambient temperatures by long electrical leads running from the cyrogenic environment to ambient. There are many applications, outside those using superconducting devices, in which there are advantages to be gained by placing part or all of the electronic system in the cryogenic environment adjacent to the measuring point. This paper discusses the requirements for an ideal cold electronic instrumentation system and then reviews the present state of the art in relation to off-the-shelf electronic components, devices and integrated circuits, and the published literature. The integration of sensors/transducers with cold electronics is discussed and areas for development are outlined

  16. Investigating Clinically and Scientifically Useful Cut Points on the Compulsive Sexual Behavior Inventory.

    Science.gov (United States)

    Miner, Michael H; Raymond, Nancy; Coleman, Eli; Swinburne Romine, Rebecca

    2017-05-01

    One of the major obstacles to conducting epidemiologic research and determining the incidence and prevalence of compulsive sexual behavior (CSB) has been the lack of relevant empirically derived cut points on the various instruments that have been used to measure the concept. To further develop the Compulsive Sexual Behavior Inventory (CSBI) through exploring predictive validity and developing an empirically determined and clinically useful cut point for defining CSB. A sample of 242 men who have sex with men was recruited from various sites in a moderate-size Midwestern city. Participants were assigned to a CSB group or a control group using an interview for the diagnosis that was patterned after the Structured Clinical Interview for the Diagnostic and Statistical Manual for Mental Disorders, Fourth Edition. The 22-item CSBI was administered as part of a larger battery of self-report inventories. Receiver operating characteristic analyses were used to compute area-under-the-curve measurements to ascertain the predictive validity of the total scale, the control subscale, and the violence subscale. Cut points were determined through consensus of experts balancing sensitivity and specificity as determined by receiver operating characteristic curves. Analyses indicated that the 22-item CSBI was a good predictor of group membership, as was the 13-item control subscale. The violence subscale added little to the predictive accuracy of the instrument; thus, it likely measures something other than CSB. Two relevant cut points were found, one that minimized false negatives and another, more conservative cut point that minimized false positives. The CSBI as currently configured measures two different constructions and only the control subscale is helpful in diagnosing CSB. Therefore, we decided to eliminate the violence subscale and move forward with a 13-item scale that we have named the CSBI-13. Two cut points were developed from this revised scale, one that is useful as a

  17. An intelligent instrument for measuring exhaust temperature of marine engine

    Science.gov (United States)

    Ma, Nan-Qi; Su, Hua; Liu, Jun

    2006-12-01

    Exhaust temperature of the marine engine is commonly measured through thermocouple. Measure deviation will occur after using the thermocouple for some time due to nonlinearity of thermocouple itself, high temperature and chemical corrosion of measure point. Frequent replacement of thermocouple will increase the operating cost. This paper designs a new intelligent instrument for solving the above-mentioned problems of the marine engine temperature measurement, which combines the conventional thermocouple temperature measurement technology and SCM(single chip microcomputer). The reading of the thermocouple is simple and precise and the calibration can be made automatically and manually.

  18. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1980-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities as well as wastes from old waste burial ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. Because of the topic of this workshop, only the assay instrumentation applied specifically to soil monitoring will be discussed here. Four types of soil monitors are described

  19. Eight year experience in open ended instrumentation laboratory

    Science.gov (United States)

    Marques, Manuel B.; Rosa, Carla C.; Marques, Paulo V. S.

    2015-10-01

    When designing laboratory courses in a Physics Major we consider a range of objectives: teaching Physics; developing lab competencies; instrument control and data acquisition; learning about measurement errors and error propagation; an introduction to project management; team work skills and scientific writing. But nowadays we face pressure to decrease laboratory hours due to the cost involved. Many universities are replacing lab classes for simulation activities, hiring PhD. and master students to give first year lab classes, and reducing lab hours. This leads to formatted lab scripts and poor autonomy of the students, and failure to enhance creativity and autonomy. In this paper we present our eight year experience with a laboratory course that is mandatory in the third year of Physics and Physical Engineering degrees. Since the students had previously two standard laboratory courses, we focused on teaching instrumentation and giving students autonomy. The course is divided in two parts: one third is dedicated to learn computer controlled instrumentation and data acquisition (based in LabView); the final 2/3 is dedicated to a group project. In this project, the team (2 or 3 students) must develop a project and present it in a typical conference format at the end of the semester. The project assignments are usually not very detailed (about two or three lines long), giving only general guidelines pointing to a successful project (students often recycle objectives putting forward a very personal project); all of them require assembling some hardware. Due to our background, about one third of the projects are related to Optics.

  20. Magnetospheric Multiscale Instrument Suite Operations and Data System

    Science.gov (United States)

    Baker, D. N.; Riesberg, L.; Pankratz, C. K.; Panneton, R. S.; Giles, B. L.; Wilder, F. D.; Ergun, R. E.

    2016-03-01

    The four Magnetospheric Multiscale (MMS) spacecraft will collect a combined volume of ˜100 gigabits per day of particle and field data. On average, only 4 gigabits of that volume can be transmitted to the ground. To maximize the scientific value of each transmitted data segment, MMS has developed the Science Operations Center (SOC) to manage science operations, instrument operations, and selection, downlink, distribution, and archiving of MMS science data sets. The SOC is managed by the Laboratory for Atmospheric and Space Physics (LASP) in Boulder, Colorado and serves as the primary point of contact for community participation in the mission. MMS instrument teams conduct their operations through the SOC, and utilize the SOC's Science Data Center (SDC) for data management and distribution. The SOC provides a single mission data archive for the housekeeping and science data, calibration data, ephemerides, attitude and other ancillary data needed to support the scientific use and interpretation. All levels of data products will reside at and be publicly disseminated from the SDC. Documentation and metadata describing data products, algorithms, instrument calibrations, validation, and data quality will be provided. Arguably, the most important innovation developed by the SOC is the MMS burst data management and selection system. With nested automation and "Scientist-in-the-Loop" (SITL) processes, these systems are designed to maximize the value of the burst data by prioritizing the data segments selected for transmission to the ground. This paper describes the MMS science operations approach, processes and data systems, including the burst system and the SITL concept.

  1. The Atacama Cosmology Telescope: Development and preliminary results of point source observations

    Science.gov (United States)

    Fisher, Ryan P.

    2009-06-01

    The Atacama Cosmology Telescope (ACT) is a six meter diameter telescope designed to measure the millimeter sky with arcminute angular resolution. The instrument is currently conducting its third season of observations from Cerro Toco in the Chilean Andes. The primary science goal of the experiment is to expand our understanding of cosmology by mapping the temperature fluctuations of the Cosmic Microwave Background (CMB) at angular scales corresponding to multipoles up to [cursive l] ~ 10000. The primary receiver for current ACT observations is the Millimeter Bolometer Array Camera (MBAC). The instrument is specially designed to observe simultaneously at 148 GHz, 218 GHz and 277 GHz. To accomplish this, the camera has three separate detector arrays, each containing approximately 1000 detectors. After discussing the ACT experiment in detail, a discussion of the development and testing of the cold readout electronics for the MBAC is presented. Currently, the ACT collaboration is in the process of generating maps of the microwave sky using our first and second season observations. The analysis used to generate these maps requires careful data calibration to produce maps of the arcminute scale CMB temperature fluctuations. Tests and applications of several elements of the ACT calibrations are presented in the context of the second season observations. Scientific exploration has already begun on preliminary maps made using these calibrations. The final portion of this thesis is dedicated to discussing the point sources observed by the ACT. A discussion of the techniques used for point source detection and photometry is followed by a presentation of our current measurements of point source spectral indices.

  2. Radiation protection instrument 1993

    International Nuclear Information System (INIS)

    1993-04-01

    The Radiation Protection Instrument, 1993 (Legislative Instrument 1559) prescribes the powers and functions of the Radiation Protection Board established under the Ghana Atomic Energy Commission by the Atomic Energy Commission (Amendment) Law, 1993 (P.N.D.C. Law 308). Also included in the Legislative Instrument are schedules on control and use of ionising radiation and radiation sources as well as procedures for notification, licensing and inspection of ionising radiation facilities. (EAA)

  3. Cross-Cultural adaptation of an instrument to computer accessibility evaluation for students with cerebral palsy

    Directory of Open Access Journals (Sweden)

    Gerusa Ferreira Lourenço

    2015-03-01

    Full Text Available The specific literature indicates that the successful education of children with cerebral palsy may require the implementation of appropriate assistive technology resources, allowing students to improve their performance and complete everyday tasks more efficiently and independently. To this end, these resources must be selected properly, emphasizing the importance of an appropriate initial assessment of the child and the possibilities of the resources available. The present study aimed to translate and adapt theoretically an American instrument that evaluates computer accessibility for people with cerebral palsy, in order to contextualize it for applicability to Brazilian students with cerebral palsy. The methodology involved the steps of translation and cross-cultural adaptation of this instrument, as well as the construction of a supplementary script for additional use of that instrument in the educational context. Translation procedures, theoretical and technical adaptation of the American instrument and theoretical analysis (content and semantics were carried out with the participation of professional experts of the special education area as adjudicators. The results pointed to the relevance of the proposal of the translated instrument in conjunction with the script built to the reality of professionals involved with the education of children with cerebral palsy, such as occupational therapists and special educators.

  4. [System design of small intellectualized ultrasound hyperthermia instrument in the LabVIEW environment].

    Science.gov (United States)

    Jiang, Feng; Bai, Jingfeng; Chen, Yazhu

    2005-08-01

    Small-scale intellectualized medical instrument has attracted great attention in the field of biomedical engineering, and LabVIEW (Laboratory Virtual Instrument Engineering Workbench) provides a convenient environment for this application due to its inherent advantages. The principle and system structure of the hyperthermia instrument are presented. Type T thermocouples are employed as thermotransducers, whose amplifier consists of two stages, providing built-in ice point compensation and thus improving work stability over temperature. Control signals produced by specially designed circuit drive the programmable counter/timer 8254 chip to generate PWM (Pulse width modulation) wave, which is used as ultrasound radiation energy control signal. Subroutine design topics such as inner-tissue real time feedback temperature control algorithm, water temperature control in the ultrasound applicator are also described. In the cancer tissue temperature control subroutine, the authors exert new improvments to PID (Proportional Integral Differential) algorithm according to the specific demands of the system and achieve strict temperature control to the target tissue region. The system design and PID algorithm improvement have experimentally proved to be reliable and excellent, meeting the requirements of the hyperthermia system.

  5. How discriminating are discriminative instruments?

    Science.gov (United States)

    Hankins, Matthew

    2008-05-27

    The McMaster framework introduced by Kirshner & Guyatt is the dominant paradigm for the development of measures of health status and health-related quality of life (HRQL). The framework defines the functions of such instruments as evaluative, predictive or discriminative. Evaluative instruments are required to be sensitive to change (responsiveness), but there is no corresponding index of the degree to which discriminative instruments are sensitive to cross-sectional differences. This paper argues that indices of validity and reliability are not sufficient to demonstrate that a discriminative instrument performs its function of discriminating between individuals, and that the McMaster framework would be augmented by the addition of a separate index of discrimination. The coefficient proposed by Ferguson (Delta) is easily adapted to HRQL instruments and is a direct, non-parametric index of the degree to which an instrument distinguishes between individuals. While Delta should prove useful in the development and evaluation of discriminative instruments, further research is required to elucidate the relationship between the measurement properties of discrimination, reliability and responsiveness.

  6. How discriminating are discriminative instruments?

    Directory of Open Access Journals (Sweden)

    Hankins Matthew

    2008-05-01

    Full Text Available Abstract The McMaster framework introduced by Kirshner & Guyatt is the dominant paradigm for the development of measures of health status and health-related quality of life (HRQL. The framework defines the functions of such instruments as evaluative, predictive or discriminative. Evaluative instruments are required to be sensitive to change (responsiveness, but there is no corresponding index of the degree to which discriminative instruments are sensitive to cross-sectional differences. This paper argues that indices of validity and reliability are not sufficient to demonstrate that a discriminative instrument performs its function of discriminating between individuals, and that the McMaster framework would be augmented by the addition of a separate index of discrimination. The coefficient proposed by Ferguson (Delta is easily adapted to HRQL instruments and is a direct, non-parametric index of the degree to which an instrument distinguishes between individuals. While Delta should prove useful in the development and evaluation of discriminative instruments, further research is required to elucidate the relationship between the measurement properties of discrimination, reliability and responsiveness.

  7. Smart antennas for nuclear instruments

    International Nuclear Information System (INIS)

    Jain, Ranjan Bala; Singhi, B.M.

    2005-01-01

    The advances in the field of computer and communications are leading to the development of smart embedded nuclear instruments. These instruments have highly sophisticated signal-processing algorithms based on FPGA and ASICS, provisions of present day connectivity and user interfaces. The developments in the connectivity, standards and bus technologies have made possible to access these instruments on LAN and WAN with suitable reliability and security. To get rid of wires i.e. in order to access these instruments, without wires at any place, wireless technology has evolved and become integral part of day-to-day activities. The environment monitoring can be done remotely, if smart antennas are incorporated on these instruments

  8. Nuclear instrumentation for research reactors

    International Nuclear Information System (INIS)

    Hofer, Carlos G.; Pita, Antonio; Verrastro, Claudio A.; Maino, Eduardo J.

    1997-01-01

    The nuclear instrumentation for research reactors in Argentina was developed in 70'. A gradual modernization of all the nuclear instrumentation is planned. It includes start-up and power range instrumentation, as well as field monitors, clamp, scram and rod movement control logic. The new instrumentation is linked to a computer network, based on real time operating system for data acquisition, display and logging. This paper describes the modules and whole system aspects. (author). 2 refs

  9. Comparability of Results Between a Point-of-Care and an Automated Instrument for Measurement of B-Type Natriuretic Peptide

    OpenAIRE

    Shah, Kevin; Terracciano, Garrett J; Jiang, Kevin; Maisel, Alan S; Fitzgerald, Robert L

    2010-01-01

    Objectives: Heart failure is one of the leading causes of death in the U.S. The incorporation of B-type natriuretic peptide (BNP) measurements when triaging patients presenting with shortness of breath has improved the diagnostic and prognostic ability of physicians. Currently, there are no point-of-care systems for quantifying BNP that can be used without sacrificing accuracy. We compared the analytical performance of the Abbott i-STAT analyzer, a handheld point-of-care system for measuring ...

  10. The resolution of point sources of light as analyzed by quantum detection theory

    Science.gov (United States)

    Helstrom, C. W.

    1972-01-01

    The resolvability of point sources of incoherent light is analyzed by quantum detection theory in terms of two hypothesis-testing problems. In the first, the observer must decide whether there are two sources of equal radiant power at given locations, or whether there is only one source of twice the power located midway between them. In the second problem, either one, but not both, of two point sources is radiating, and the observer must decide which it is. The decisions are based on optimum processing of the electromagnetic field at the aperture of an optical instrument. In both problems the density operators of the field under the two hypotheses do not commute. The error probabilities, determined as functions of the separation of the points and the mean number of received photons, characterize the ultimate resolvability of the sources.

  11. Evaluation of environmental policy instruments - a case study of the Finnish pulp and paper and chemical industries

    International Nuclear Information System (INIS)

    Hilden, M.; Lepola, J.; Mickwitz, P.; Palosaari, M.; Similae, J.; Sjoeblom, S.; Mulders, A.; Vedung, E.

    2002-01-01

    This research-based evaluation of environmental policy Instruments in Finland is focussed on regulatory instruments based on the Water Act, the Air Pollution Control Act and the Chemicals Act, on electricity taxation and on voluntary environmental management systems. The examined policy instruments have had several positive effects. They have directed major industrial point source polluters towards solving environmental problems. The transparency has been an important factor ensuring the success of the policy instruments and in avoiding the regulatory capture that could have thrived in a system largely based on negotiations between operators and authorities. The transparency has made it easy for Finnish firms to adopt environmental management systems and an open attitude to environmental reporting. The permit conditions have not directly resulted in innovations, but they have contributed to the diffusion of end-of-pipe technology and have contributed to innovations by expanding the market for environmentally better technical solutions. The permit systems have also indirectly contributed to innovations by creating a demand for environmental experts and environmental education. Networks have clearly developed as a consequence of and in response to regulatory instruments. These networks appear to have had their greatest significance prior to the permit procedures. The trend has been towards a greater emphasis of the communication in the networks prior to the presentation of an application in order to ensure a smoothly functioning permit process. In the networks contributing to innovations and the diffusion of innovations authorities have largely been outsiders, except when an innovation has become a de facto standard for permit conditions. The different kind of effects, the complexity of consequences and the uncertainties with respect to causes and effects mean that studies aiming at evaluating the overall worth and merit of an environmental policy instrument should

  12. Refining Game Addiction Questionnairs: Evidence for a natural cut-off point?

    OpenAIRE

    Nielsen, Rune Kristian

    2013-01-01

    This paper presents data from a pilot study, which was designed to illuminate critical flaws in the currently used instruments used to measure the prevalence of ‘computer game addiction’. The study found that the prevalence rate could be set anywhere between 23% and 0,6% depending on how the data set is scored. Thus demonstrating how an arbitrarily set of cut-off point in prevalence studies can yield wildly varying prevalence rates. The data further show that making implicit assumptions about...

  13. Advancements in Actuated Musical Instruments

    DEFF Research Database (Denmark)

    Overholt, Daniel; Berdahl, Edgar; Hamilton, Robert

    2011-01-01

    are physical instruments that have been endowed with virtual qualities controlled by a computer in real-time but which are nevertheless tangible. These instruments provide intuitive and engaging new forms of interaction. They are different from traditional (acoustic) and fully automated (robotic) instruments...

  14. Software-Enabled Modular Instrumentation Systems

    NARCIS (Netherlands)

    Soijer, M.W.

    2003-01-01

    Like most other types of instrumentation systems, flight test instrumentation is not produced in series; its development is a one-time achievement by a test department. With the introduction of powerful digital computers, instrumentation systems have included data analysis tasks that were previously

  15. Nuclear instrument technician training

    International Nuclear Information System (INIS)

    Wollesen, E.S.

    1991-01-01

    This paper reports on Nuclear Instrument Technician (NIT) training that has developed at an accelerated rate over the past three decades. During the 1960's commercial nuclear power plants were in their infancy. For that reason, there is little wonder that NIT training had little structure and little creditability. NIT training, in many early plants, was little more than On-The Job Training (OJT). The seventies brought changes in Instrumentation and Controls as well as emphasis on the requirements for more in depth training and documentation. As in the seventies, the eighties saw not only changes in technologies but tighter requirements, standardized training and the development of accredited Nuclear Instrument Training; thus the conclusion: Nuclear Instrument Training Isn't What It Used To Be

  16. Industrial instrumentation principles and design

    CERN Document Server

    Padmanabhan, Tattamangalam R

    2000-01-01

    Pneumatic, hydraulic and allied instrumentation schemes have given way to electronic schemes in recent years thanks to the rapid strides in electronics and allied areas. Principles, design and applications of such state-of-the-art instrumentation schemes form the subject matter of this book. Through representative examples, the basic building blocks of instrumentation schemes are identified and each of these building blocks discussed in terms of its design and interface characteristics. The common generic schemes synthesized with such building blocks are dealt with subsequently. This forms the scope of Part I. The focus in Part II is on application. Displacement and allied instrumentation, force and allied instrumentation and process instrumentation in terms of temperature, flow, pressure level and other common process variables are dealt with separately and exhaustively. Despite the diversity in the sensor principles and characteristics and the variety in the applications and their environments, it is possib...

  17. Systematic Review of Measurement Property Evidence for 8 Financial Management Instruments in Populations With Acquired Cognitive Impairment.

    Science.gov (United States)

    Engel, Lisa; Chui, Adora; Beaton, Dorcas E; Green, Robin E; Dawson, Deirdre R

    2018-03-07

    To critically appraise the measurement property evidence (ie, psychometric) for 8 observation-based financial management assessment instruments. Seven databases were searched in May 2015. Two reviewers used an independent decision-agreement process to select studies of measurement property evidence relevant to populations with adulthood acquired cognitive impairment, appraise the quality of the evidence, and extract data. Twenty-one articles were selected. This review used the COnsensus-based Standards for the selection of health Measurement Instruments review guidelines and 4-point tool to appraise evidence. After appraising the methodologic quality, the adequacy of results and volume of evidence per instrument were synthesized. Measurement property evidence with high risk of bias was excluded from the synthesis. The volume of measurement property evidence per instrument is low; most instruments had 1 to 3 included studies. Many included studies had poor methodologic quality per measurement property evidence area examined. Six of the 8 instruments reviewed had supporting construct validity/hypothesis-testing evidence of fair methodologic quality. There is a dearth of acceptable quality content validity, reliability, and responsiveness evidence for all 8 instruments. Rehabilitation practitioners assess financial management functions in adults with acquired cognitive impairments. However, there is limited published evidence to support using any of the reviewed instruments. Practitioners should exercise caution when interpreting the results of these instruments. This review highlights the importance of appraising the quality of measurement property evidence before examining the adequacy of the results and synthesizing the evidence. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  18. A Geometrical Method for Sound-Hole Size and Location Enhancement in Lute Family Musical Instruments: The Golden Method

    Directory of Open Access Journals (Sweden)

    Soheil Jafari

    2017-11-01

    Full Text Available This paper presents a new analytical approach, the Golden Method, to enhance sound-hole size and location in musical instruments of the lute family in order to obtain better sound damping characteristics based on the concept of the golden ratio and the instrument geometry. The main objective of the paper is to increase the capability of lute family musical instruments in keeping a note for a certain time at a certain level to enhance the instruments’ orchestral characteristics. For this purpose, a geometry-based analytical method, the Golden Method is first described in detail in an itemized feature. A new musical instrument is then developed and tested to confirm the ability of the Golden Method in optimizing the acoustical characteristics of musical instruments from a damping point of view by designing the modified sound-hole. Finally, the new-developed instrument is tested, and the obtained results are compared with those of two well-known instruments to confirm the effectiveness of the proposed method. The experimental results show that the suggested method is able to increase the sound damping time by at least 2.4% without affecting the frequency response function and other acoustic characteristics of the instrument. This methodology could be used as the first step in future studies on design, optimization and evaluation of musical instruments of the lute family (e.g., lute, oud, barbat, mandolin, setar, and etc..

  19. Energy conserving schemes for the simulation of musical instrument contact dynamics

    Science.gov (United States)

    Chatziioannou, Vasileios; van Walstijn, Maarten

    2015-03-01

    Collisions are an innate part of the function of many musical instruments. Due to the nonlinear nature of contact forces, special care has to be taken in the construction of numerical schemes for simulation and sound synthesis. Finite difference schemes and other time-stepping algorithms used for musical instrument modelling purposes are normally arrived at by discretising a Newtonian description of the system. However because impact forces are non-analytic functions of the phase space variables, algorithm stability can rarely be established this way. This paper presents a systematic approach to deriving energy conserving schemes for frictionless impact modelling. The proposed numerical formulations follow from discretising Hamilton's equations of motion, generally leading to an implicit system of nonlinear equations that can be solved with Newton's method. The approach is first outlined for point mass collisions and then extended to distributed settings, such as vibrating strings and beams colliding with rigid obstacles. Stability and other relevant properties of the proposed approach are discussed and further demonstrated with simulation examples. The methodology is exemplified through a case study on tanpura string vibration, with the results confirming the main findings of previous studies on the role of the bridge in sound generation with this type of string instrument.

  20. Instrumental analysis, second edition

    International Nuclear Information System (INIS)

    Christian, G.D.; O'Reilly, J.E.

    1988-01-01

    The second edition of Instrumental Analysis is a survey of the major instrument-based methods of chemical analysis. It appears to be aimed at undergraduates but would be equally useful in a graduate course. The volume explores all of the classical quantitative methods and contains sections on techniques that usually are not included in a semester course in instrumentation (such as electron spectroscopy and the kinetic methods). Adequate coverage of all of the methods contained in this book would require several semesters of focused study. The 25 chapters were written by different authors, yet the style throughout the book is more uniform than in the earlier edition. With the exception of a two-chapter course in analog and digital circuits, the book purports to de-emphasize instrumentation, focusing more on the theory behind the methods and the application of the methods to analytical problems. However, a detailed analysis of the instruments used in each method is by no means absent. The book has the favor of a user's guide to analysis

  1. Arc-Second Pointer for Balloon-Borne Astronomical Instrument

    Science.gov (United States)

    Ward, Philip R.; DeWeese, Keith

    2004-01-01

    A control system has been designed to keep a balloon-borne scientific instrument pointed toward a celestial object within an angular error of the order of an arc second. The design is intended to be adaptable to a large range of instrument payloads. The initial payload to which the design nominally applies is considered to be a telescope, modeled as a simple thin-walled cylinder 24 ft (approx.= 7.3 m) long, 3 ft (approx.= 0.91 m) in diameter, weighing 1,500 lb (having a mass of .680 kg). The instrument would be mounted on a set of motor-driven gimbals in pitch-yaw configuration. The motors on the gimbals would apply the control torques needed for fine adjustments of the instrument in pitch and yaw. The pitch-yaw mount would, in turn, be suspended from a motor mount at the lower end of a pair of cables hanging down from the balloon (see figure). The motor in this mount would be used to effect coarse azimuth control of the pitch-yaw mount. A notable innovation incorporated in the design is a provision for keeping the gimbal bearings in constant motion. This innovation would eliminate the deleterious effects of static friction . something that must be done in order to achieve the desired arc-second precision. Another notable innovation is the use of linear accelerometers to provide feedback that would facilitate the early detection and counteraction of disturbance torques before they could integrate into significant angular-velocity and angular-position errors. The control software processing the sensor data would be capable of distinguishing between translational and rotational accelerations. The output of the accelerometers is combined with that of angular position and angular-velocity sensors into a proportional + integral + derivative + acceleration control law for the pitch and yaw torque motors. Preliminary calculations have shown that with appropriate gains, the power demand of the control system would be low enough to be satisfiable by means of storage

  2. High speed cinematography of the initial break-point of latex condoms during the air burst test.

    Science.gov (United States)

    Stube, R; Voeller, B; Davidhazy, A

    1990-06-01

    High speed cinematography of latex condoms inflated to burst under standard (ISO) conditions reveals that rupture of the condom typically is initiated at a small focal point on the shank of the condom and then rapidly propagates throughout the condom's surface, often ending with partial or full severance of the condom at its point of attachment to the air burst instrument. This sequence of events is the reverse of that sometimes hypothesized to occur, where initiation of burst was considered to begin at the attachment point and to constitute a testing method artifact. This hypothesis of breakage at the attachment point, if true, would diminish the value of the air burst test as a standard for assessing manufacturing quality control as well as for condom strength measurements and comparisons.

  3. Long open-path instrument for simultaneously monitoring of methane, CO2 and water vapor

    Science.gov (United States)

    Simeonov, Valentin; Parlange, Marc

    2013-04-01

    A new, long open-path instrument for monitoring of path-averaged methane, CO2 and water vapor concentrations will be presented. The instrument is built on the monostatic scheme (transceiver -distant retroreflector). A VCSEL with a central wavelength of 1654 nm is used as a light source. The receiver is built around a 20 cm Newtonian telescope. The design optical path length is 2000 m but can be further extended. To avoid distortions in the shape of the spectral lines caused by atmospheric turbulences they are scanned within 1 µs. The expected concentration resolution for the above mentioned path length is of the order of 2 ppb for methane, 100 ppb for CO2 and 100 ppm for water vapor. The instrument is developed at the Swiss Federal Institute of Technology - Lausanne (EPFL) Switzerland and will be used within the GAW+ CH program for long-term monitoring of background methane and CO2 concentrations in the Swiss Alps. The initial calibration validation tests at EPFL were completed in December 2012 and the instrument will be installed at the beginning of 2013 at the High Altitude Research Station Jungfraujoch (HARSJ). The HARSJ is located at 3580 m ASL and is one of the 24 global GAW stations. One of the goals of the project is to compare path-averaged to the ongoing point measurements of methane in order to identify possible influence of the station. Future deployments of a copy of the instrument include the Canadian arctic and Siberian wetlands. The instrument can be used for ground truthing of satellite observation as well.

  4. Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis.

    Science.gov (United States)

    John-Baptiste, A; Sowerby, L J; Chin, C J; Martin, J; Rotenberg, B W

    2016-01-01

    When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems.

  5. Multiple types of motives don't multiply the motivation of West Point cadets.

    Science.gov (United States)

    Wrzesniewski, Amy; Schwartz, Barry; Cong, Xiangyu; Kane, Michael; Omar, Audrey; Kolditz, Thomas

    2014-07-29

    Although people often assume that multiple motives for doing something will be more powerful and effective than a single motive, research suggests that different types of motives for the same action sometimes compete. More specifically, research suggests that instrumental motives, which are extrinsic to the activities at hand, can weaken internal motives, which are intrinsic to the activities at hand. We tested whether holding both instrumental and internal motives yields negative outcomes in a field context in which various motives occur naturally and long-term educational and career outcomes are at stake. We assessed the impact of the motives of over 10,000 West Point cadets over the period of a decade on whether they would become commissioned officers, extend their officer service beyond the minimum required period, and be selected for early career promotions. For each outcome, motivation internal to military service itself predicted positive outcomes; a relationship that was negatively affected when instrumental motives were also in evidence. These results suggest that holding multiple motives damages persistence and performance in educational and occupational contexts over long periods of time.

  6. PET/CT: underlying physics, instrumentation, and advances.

    Science.gov (United States)

    Torres Espallardo, I

    Since it was first introduced, the main goal of PET/CT has been to provide both PET and CT images with high clinical quality and to present them to radiologists and specialists in nuclear medicine as a fused, perfectly aligned image. The use of fused PET and CT images quickly became routine in clinical practice, showing the great potential of these hybrid scanners. Thanks to this success, manufacturers have gone beyond considering CT as a mere attenuation corrector for PET, concentrating instead on design high performance PET and CT scanners with more interesting features. Since the first commercial PET/CT scanner became available in 2001, both the PET component and the CT component have improved immensely. In the case of PET, faster scintillation crystals with high stopping power such as LYSO crystals have enabled more sensitive devices to be built, making it possible to reduce the number of undesired coincidence events and to use time of flight (TOF) techniques. All these advances have improved lesion detection, especially in situations with very noisy backgrounds. Iterative reconstruction methods, together with the corrections carried out during the reconstruction and the use of the point-spread function, have improved image quality. In parallel, CT instrumentation has also improved significantly, and 64- and 128-row detectors have been incorporated into the most modern PET/CT scanners. This makes it possible to obtain high quality diagnostic anatomic images in a few seconds that both enable the correction of PET attenuation and provide information for diagnosis. Furthermore, nowadays nearly all PET/CT scanners have a system that modulates the dose of radiation that the patient is exposed to in the CT study in function of the region scanned. This article reviews the underlying physics of PET and CT imaging separately, describes the changes in the instrumentation and standard protocols in a combined PET/CT system, and finally points out the most important

  7. The 2007 ESO Instrument Calibration Workshop

    CERN Document Server

    Kaufer, Andreas; ESO Workshop

    2008-01-01

    The 2007 ESO Instrument Calibration workshop brought together more than 120 participants with the objective to a) foster the sharing of information, experience and techniques between observers, instrument developers and instrument operation teams, b) review the actual precision and limitations of the applied instrument calibration plans, and c) collect the current and future requirements by the ESO users. These present proceedings include the majority of the workshop’s contributions and document the status quo of instrument calibration at ESO in large detail. Topics covered are: Optical Spectro-Imagers, Optical Multi-Object Spectrographs, NIR and MIR Spectro-Imagers, High-Resolution Spectrographs, Integral Field Spectrographs, Adaptive Optics Instruments, Polarimetric Instruments, Wide Field Imagers, Interferometric Instruments as well as other crucial aspects such as data flow, quality control, data reduction software and atmospheric effects. It was stated in the workshop that "calibration is a life-long l...

  8. The Choice of Innovation Policy Instruments

    DEFF Research Database (Denmark)

    Borrás, Susana; Edquist, Charles

    The purpose of this article is to discuss the different types of instruments of innovation policy, to examine how governments and public agencies in different countries and different times have used these instruments differently, to explore the political nature of instrument choice and design (and...... associated issues), and to elaborate a set of criteria for the selection and design of the instruments in relation to the formulation of innovation policy. The article argues that innovation policy instruments must be designed and combined into mixes in ways that address the problems of the innovation system....... These mixes are often called “policy mix”. The problem-oriented nature of the design of instrument mixes is what makes innovation policy instruments ‘systemic’....

  9. The Choice of Innovation Policy Instruments

    DEFF Research Database (Denmark)

    Borrás, Susana; Edquist, Charles

    2013-01-01

    The purpose of this article is to discuss the different types of instruments of innovation policy, to examine how governments and public agencies in different countries and different times have used these instruments differently, to explore the political nature of instrument choice and design (and...... associated issues), and to elaborate a set of criteria for the selection and design of the instruments in relation to the formulation of innovation policy. The article argues that innovation policy instruments must be designed and combined into mixes in ways that address the problems of the innovation system....... These mixes are often called “policy mix”. The problem-oriented nature of the design of instrument mixes is what makes innovation policy instruments ‘systemic’....

  10. Micro Coronal Bright Points Observed in the Quiet Magnetic Network by SOHO/EIT

    Science.gov (United States)

    Falconer, D. A.; Moore, R. L.; Porter, J. G.

    1997-01-01

    When one looks at SOHO/EIT Fe XII images of quiet regions, one can see the conventional coronal bright points (> 10 arcsec in diameter), but one will also notice many smaller faint enhancements in brightness (Figure 1). Do these micro coronal bright points belong to the same family as the conventional bright points? To investigate this question we compared SOHO/EIT Fe XII images with Kitt Peak magnetograms to determine whether the micro bright points are in the magnetic network and mark magnetic bipoles within the network. To identify the coronal bright points, we applied a picture frame filter to the Fe XII images; this brings out the Fe XII network and bright points (Figure 2) and allows us to study the bright points down to the resolution limit of the SOHO/EIT instrument. This picture frame filter is a square smoothing function (hlargelyalf a network cell wide) with a central square (quarter of a network cell wide) removed so that a bright point's intensity does not effect its own background. This smoothing function is applied to the full disk image. Then we divide the original image by the smoothed image to obtain our filtered image. A bright point is defined as any contiguous set of pixels (including diagonally) which have enhancements of 30% or more above the background; a micro bright point is any bright point 16 pixels or smaller in size. We then analyzed the bright points that were fully within quiet regions (0.6 x 0.6 solar radius) centered on disk center on six different days.

  11. Evaluation of the i-STAT point-of-care analyzer in critically ill adult patients.

    Science.gov (United States)

    Steinfelder-Visscher, Jacoline; Teerenstra, Steven; Gunnewiek, Jacqueline M T Klein; Weerwind, Patrick W

    2008-03-01

    Point-of-care analyzers may benefit therapeutic decision making by reducing turn-around-time for samples. This is especially true when biochemical parameters exceed the clinical reference range, in which acute and effective treatment is essential. We therefore evaluated the analytical performance of the i-STAT point-of-care analyzer in two critically ill adult patient populations. During a 3-month period, 48 blood samples from patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) and 42 blood samples from non-cardiac patients who needed intensive care treatment were analyzed on both the i-STAT analyzer (CPB and non-CPB mode, respectively) and our laboratory analyzers (RapidLab 865/Sysmex XE-2100 instrument). The agreement analysis for quantitative data was used to compare i-STAT to RapidLab for blood gas/electrolytes and for hematocrit with the Sysmex instrument. Point-of-care electrolytes and blood gases had constant deviation, except for pH, pO2, and hematocrit. A clear linear trend in deviation of i-STAT from RapidLab was noticed for pH during CPB (r = 0.32, p = .03) and for pO2 > 10 kPa during CPB (r = -0.59, p pO2 pO2 pO2 range (10.6 pO2 range below 25% (n = 11) using the i-STAT. The i-STAT analyzer is suitable for point-of-care testing of electrolytes and blood gases in critically ill patients, except for high pO2. However, the discrepancy in hematocrit bias shows that accuracy established in one patient population cannot be automatically extrapolated to other patient populations, thus stressing the need for separate evaluation.

  12. The IKARUS instrument

    International Nuclear Information System (INIS)

    Gerster, H.J.; Stein, G.

    1994-01-01

    When the Federal Government decided on a 25% reduction of CO 2 emissions till 2005 in 1990 the necessity resulted that an instrument has to be developed for the analysis and assessment of the ecological, economic and energetic impact of different reduction strategies. The development task was awarded by the BMFT to the Research Centre Juelich in cooperation with well-known institutions of energy system research. The total instrument is scheduled to be finished by the end of 1994. For the decentral use of the instrument by a wide specialist public the developed models and data banks which are equipped with a user-friendly surface are suited for larger PCs (486, 16 MB RAM/500-1000 MB ROM). (orig.) [de

  13. Measuring Principal Performance: How Rigorous Are Commonly Used Principal Performance Assessment Instruments? A Quality School Leadership Issue Brief

    Science.gov (United States)

    Condon, Christopher; Clifford, Matthew

    2010-01-01

    This brief reviews the publicly available principal assessments and points superintendents and policy makers toward strong instruments to measure principal performance. Specifically, the measures included in this review are expressly intended to evaluate principal performance and have varying degrees of publicly available evidence of psychometric…

  14. Verification of the Indicating Measuring Instruments Taking into Account their Instrumental Measurement Uncertainty

    Directory of Open Access Journals (Sweden)

    Zakharov Igor

    2017-12-01

    Full Text Available The specific features of the measuring instruments verification based on the results of their calibration are considered. It is noted that, in contrast to the verification procedure used in the legal metrology, the verification procedure for calibrated measuring instruments has to take into account the uncertainty of measurements into account. In this regard, a large number of measuring instruments, considered as those that are in compliance after verification in the legal metrology, turns out to be not in compliance after calibration. In this case, it is necessary to evaluate the probability of compliance of indicating measuring instruments. The procedure of compliance probability determination on the basis of the Monte Carlo method is considered. An example of calibration of a Vernier caliper is given.

  15. Minimally invasive instrumentation without fusion during posterior thoracic corpectomies: a comparison of percutaneously instrumented nonfused segments with open instrumented fused segments.

    Science.gov (United States)

    Lau, Darryl; Chou, Dean

    2017-07-01

    OBJECTIVE During the mini-open posterior corpectomy, percutaneous instrumentation without fusion is performed above and below the corpectomy level. In this study, the authors' goal was to compare the perioperative and long-term implant failure rates of patients who underwent nonfused percutaneous instrumentation with those of patients who underwent traditional open instrumented fusion. METHODS Adult patients who underwent posterior thoracic corpectomies with cage reconstruction between 2009 and 2014 were identified. Patients who underwent mini-open corpectomy had percutaneous instrumentation without fusion, and patients who underwent open corpectomy had instrumented fusion above and below the corpectomy site. The authors compared perioperative outcomes and rates of implant failure requiring reoperation between the open (fused) and mini-open (unfused) groups. RESULTS A total of 75 patients were identified, and 53 patients (32 open and 21 mini-open) were available for followup. The mean patient age was 52.8 years, and 56.6% of patients were male. There were no significant differences in baseline variables between the 2 groups. The overall perioperative complication rate was 15.1%, and there was no significant difference between the open and mini-open groups (18.8% vs 9.5%; p = 0.359). The mean hospital stay was 10.5 days. The open group required a significantly longer stay than the mini-open group (12.8 vs 7.1 days; p open and mini-open groups at 6 months (3.1% vs 0.0%, p = 0.413), 1 year (10.7% vs 6.2%, p = 0.620), and 2 years (18.2% vs 8.3%, p = 0.438). The overall mean follow-up was 29.2 months. CONCLUSIONS These findings suggest that percutaneous instrumentation without fusion in mini-open transpedicular corpectomies offers similar implant failure and reoperation rates as open instrumented fusion as far out as 2 years of follow-up.

  16. Computer aided instrumented Charpy test applied dynamic fracture toughness evaluation system

    International Nuclear Information System (INIS)

    Kobayashi, Toshiro; Niinomi, Mitsuo

    1986-01-01

    Micro computer aided data treatment system and personal computer aided data analysis system were applied to the traditional instrumented Charpy impact test system. The analysis of Charpy absorbed energy (E i , E p , E t ) and load (P y , P m ), and the evaluation of dynamic toughness through whole fracture process, i.e. J Id , J R curve and T mat was examined using newly developed computer aided instrumented Charpy impact test system. E i , E p , E t , P y and P m were effectively analyzed using moving average method and printed out automatically by micro computer aided data treatment system. J Id , J R curve and T mat could be measured by stop block test method. Then, J Id , J R curve and T mat were effectively estimated using compliance changing rate method and key curve method on the load-load point displacement curve of single fatigue cracked specimen by personal computer aided data analysis system. (author)

  17. The social conditions of instrumental action: Problems in the sociological understanding of rational choice theory

    Directory of Open Access Journals (Sweden)

    Bruno Sciberras de Carvalho

    2008-01-01

    Full Text Available This article critically analyzes new sociological approaches to the rational choice theory which - beyond examining political or economic practices - link the notion of instrumental rationality to social issues and themes. The article begins by highlighting the issue of trust, indicating the functionality of certain social arrangements in collective problem-solving. The paper goes on to demonstrate that problems emerge with the theory when it attempts to explain the feasibility of social norms in impersonal, comprehensive contexts. Thus, the fundamental point that appears to be missing from rational choice theory is the perception that individual decisions and instrumental conduct itself incorporate dispositions that in a sense are beyond the actors' control.

  18. “Lock-in” effect of emission standard and its impact on the choice of market based instruments

    International Nuclear Information System (INIS)

    Haoqi, Qian; Libo, Wu; Weiqi, Tang

    2017-01-01

    A country's existing emission standard policy will lead to a “lock in” effect. When the country plans to adopt new market-based instruments to control greenhouse gas emissions, it must consider this effect as it chooses among instruments to avoid larger efficiency loss. In this paper, we find that the “lock in” effect will cause a kink point to occur on the marginal abatement cost (MAC) curve. This change of shape for the MAC curve reminds us to be cautious in choosing market-based instruments when applying Weitzman's rule. We also introduce this concept into a dynamic multi-regional computable general equilibrium (CGE) model for China and simulate MAC curves for all regions. After applying Weitzman's rule, we propose a timeline for introducing price instruments under different marginal benefit (MB) curve scenarios. - Highlights: • China's existing carbon intensity policy has a “lock-in” effect and leads to a “kink point” on MAC. • A dynamic inter-regional CGE model is developed to simulate the regional kinked MAC curves in China. • A timeline of introducing new market based instrument is proposed by combining different MB scenarios.

  19. Environment for the instruments

    International Nuclear Information System (INIS)

    Ambro, P.

    1992-01-01

    A properly conditioned AC power supply is necessary for reliable functioning of instruments. Electric mains power is produced primarily for industry, workshops, lighting and household uses. Its quality is adjusted to these uses. In areas sand countries with a fast growing demand for electric power, these requirements are far from being met. Electronic instruments and computers, especially in these countries, need protection against disturbances of the mains supply. A clean and dry environment is needed for reliable functioning and long life of instruments. High humidity, specially at higher temperatures, changes the characteristics of electronic components. Moreover, under these conditions fungal growth causes leakage of currents and corrosion causes poor contacts. The presence of dust enhances these effects. They give rise to malfunction of instruments, particularly of high voltage equipment

  20. Environment for the instruments

    Energy Technology Data Exchange (ETDEWEB)

    Ambro, P

    1993-12-31

    A properly conditioned AC power supply is necessary for reliable functioning of instruments. Electric mains power is produced primarily for industry, workshops, lighting and household uses. Its quality is adjusted to these uses. In areas sand countries with a fast growing demand for electric power, these requirements are far from being met. Electronic instruments and computers, especially in these countries, need protection against disturbances of the mains supply. A clean and dry environment is needed for reliable functioning and long life of instruments. High humidity, specially at higher temperatures, changes the characteristics of electronic components. Moreover, under these conditions fungal growth causes leakage of currents and corrosion causes poor contacts. The presence of dust enhances these effects. They give rise to malfunction of instruments, particularly of high voltage equipment

  1. Evaluating the Relational Coordination instrument

    DEFF Research Database (Denmark)

    Edwards, Kasper; Lundstrøm, Sanne Lykke

    2014-01-01

    consistency, interrater agreement and reliability, structural validity, content validity. However as relational coordination is being used as a diagnostics tool it is important to examine further if the instrument can measure changes. Indeed we need to know how precise and sensitive the instrument is when....... We distinguish between statistical and clinical significance. Statistical significance is calculated using T-test. Clinical significance is the minimal amount of change in relational coordination score that is not considered noise. Sensitivity of the instrument i.e. the ability of the instrument...

  2. Preservation of root canal anatomy using self-adjusting file instrumentation with glide path prepared by 20/0.02 hand files versus 20/0.04 rotary files

    Science.gov (United States)

    Jain, Niharika; Pawar, Ajinkya M.; Ukey, Piyush D.; Jain, Prashant K.; Thakur, Bhagyashree; Gupta, Abhishek

    2017-01-01

    Objectives: To compare the relative axis modification and canal concentricity after glide path preparation with 20/0.02 hand K-file (NITIFLEX®) and 20/0.04 rotary file (HyFlex™ CM) with subsequent instrumentation with 1.5 mm self-adjusting file (SAF). Materials and Methods: One hundred and twenty ISO 15, 0.02 taper, Endo Training Blocks (Dentsply Maillefer, Ballaigues, Switzerland) were acquired and randomly divided into following two groups (n = 60): group 1, establishing glide path till 20/0.02 hand K-file (NITIFLEX®) followed by instrumentation with 1.5 mm SAF; and Group 2, establishing glide path till 20/0.04 rotary file (HyFlex™ CM) followed by instrumentation with 1.5 mm SAF. Pre- and post-instrumentation digital images were processed with MATLAB R 2013 software to identify the central axis, and then superimposed using digital imaging software (Picasa 3.0 software, Google Inc., California, USA) taking five landmarks as reference points. Student's t-test for pairwise comparisons was applied with the level of significance set at 0.05. Results: Training blocks instrumented with 20/0.04 rotary file and SAF were associated less deviation in canal axis (at all the five marked points), representing better canal concentricity compared to those, in which glide path was established by 20/0.02 hand K-files followed by SAF instrumentation. Conclusion: Canal geometry is better maintained after SAF instrumentation with a prior glide path established with 20/0.04 rotary file. PMID:28855752

  3. The effect of abrading and cutting instruments on machinability of dental ceramics.

    Science.gov (United States)

    Sakoda, Satoshi; Nakao, Noriko; Watanabe, Ikuya

    2018-03-16

    The aim was to investigate the effect of machining instruments on machinability of dental ceramics. Four dental ceramics, including two zirconia ceramics were machined by three types (SiC, diamond vitrified, and diamond sintered) of wheels with a hand-piece engine and two types (diamond and carbide) of burs with a high-speed air turbine. The machining conditions used were abrading speeds of 10,000 and 15,000 r.p.m. with abrading force of 100 gf for the hand-piece engine, and a pressure of 200 kPa and a cutting force of 80 gf for the air-turbine hand-piece. The machinability efficiency was evaluated by volume losses after machining the ceramics. A high-abrading speed had high-abrading efficiency (high-volume loss) compared to low-abrading speed in all abrading instruments used. The diamond vitrified wheels demonstrated higher volume loss for two zirconia ceramics than those of SiC and diamond sintered wheels. When the high-speed air-turbine instruments were used, the diamond points showed higher volume losses compared to the carbide burs for one ceramic and two zirconia ceramics with high-mechanical properties. The results of this study indicated that the machinability of dental ceramics depends on the mechanical and physical properties of dental ceramics and machining instruments. The abrading wheels show autogenous action of abrasive grains, in which ground abrasive grains drop out from the binder during abrasion, then the binder follow to wear out, subsequently new abrasive grains come out onto the instrument surface (autogenous action) and increase the grinding amount (volume loss) of grinding materials.

  4. Developing a workplace resilience instrument.

    Science.gov (United States)

    Mallak, Larry A; Yildiz, Mustafa

    2016-05-27

    Resilience benefits from the use of protective factors, as opposed to risk factors, which are associated with vulnerability. Considerable research and instrument development has been conducted in clinical settings for patients. The need existed for an instrument to be developed in a workplace setting to measure resilience of employees. This study developed and tested a resilience instrument for employees in the workplace. The research instrument was distributed to executives and nurses working in the United States in hospital settings. Five-hundred-forty completed and usable responses were obtained. The instrument contained an inventory of workplace resilience, a job stress questionnaire, and relevant demographics. The resilience items were written based on previous work by the lead author and inspired by Weick's [1] sense-making theory. A four-factor model yielded an instrument having psychometric properties showing good model fit. Twenty items were retained for the resulting Workplace Resilience Instrument (WRI). Parallel analysis was conducted with successive iterations of exploratory and confirmatory factor analyses. Respondents were classified based on their employment with either a rural or an urban hospital. Executives had significantly higher WRI scores than nurses, controlling for gender. WRI scores were positively and significantly correlated with years of experience and the Brief Job Stress Questionnaire. An instrument to measure individual resilience in the workplace (WRI) was developed. The WRI's four factors identify dimensions of workplace resilience for use in subsequent investigations: Active Problem-Solving, Team Efficacy, Confident Sense-Making, and Bricolage.

  5. Medical instruments in museums

    DEFF Research Database (Denmark)

    Söderqvist, Thomas; Arnold, Ken

    2011-01-01

    This essay proposes that our understanding of medical instruments might benefit from adding a more forthright concern with their immediate presence to the current historical focus on simply decoding their meanings and context. This approach is applied to the intriguingly tricky question of what...... actually is meant by a "medical instrument." It is suggested that a pragmatic part of the answer might lie simply in reconsidering the holdings of medical museums, where the significance of the physical actuality of instruments comes readily to hand....

  6. Design requirements for the SWIFT instrument

    International Nuclear Information System (INIS)

    Rahnama, P; McDade, I; Shepherd, G; Gault, W

    2013-01-01

    The Stratospheric Wind Interferometer for Transport studies (SWIFT) instrument is a proposed limb-viewing satellite instrument that employs the method of Doppler Michelson interferometry to measure stratospheric wind velocities and ozone densities in the altitude range of 15–45 km. The values of the main instrument parameters including filter system parameters and Michelson interferometer parameters are derived using simulations and analyses. The system design requirements for the instrument and spacecraft are presented and discussed. Some of the retrieval-imposed design requirements are also discussed. Critical design issues are identified. The design optimization process is described. The sensitivity of wind measurements to instrument characteristics is investigated including the impact on critical design issues. Using sensitivity analyses, the instrument parameters were iteratively optimized in order to meet the science objectives. It is shown that wind measurements are sensitive to the thermal sensitivity of the instrument components, especially the narrow filter and the Michelson interferometer. The optimized values of the main system parameters including Michelson interferometer optical path difference, instrument visibility, instrument responsivity and knowledge of spacecraft velocity are reported. This work also shows that the filter thermal drift and the Michelson thermal drift are two main technical risks. (paper)

  7. Development of CAMAC and Fastbus instrumentation

    International Nuclear Information System (INIS)

    Venkateswaran, Aruna; Behere, Anita; Ghodgaonkar, M.D.; Bairi, B.R.

    1987-01-01

    This report describes the work being done towards the development of CAMAC and Fast Bus Instrumentation under the VII Five Year Plan Project 'Modernisation of Reactor Control Instrumentation and Development of CAMAC and FAST BUS Instrumentation'. The report summarises the goals, objectives, principles and concepts of CAMAC and Fast Bus Instrumentation. While emphasizing the motivation behind the development of CAMAC and Fast Bus Instrumentation, the report brings out the current status and future plans of this development program. (author)

  8. Instrumental traditions and theories of light the uses of instruments in the optical revolution

    CERN Document Server

    Chen, Xiang

    2000-01-01

    An analysis of the optical revolution in the context of early 19th century Britain. Far from merely involving the replacement of one optical theory by another, the revolution also involved substantial changes in instruments and the practices that surrounded them. People's judgements about classification, explanation and evaluation were affected by the way they used such optical instruments as spectroscopes, telescopes, polarisers, photometers, gratings, prisms and apertures. There were two instrumental traditions in this historical period, each of which nurtured a body of practice that exemplified how optical instruments should be operated, and especially how the eye should be used. These traditions functioned just like paradigms, shaping perspectives and even world views. Readership: Scholars and graduate students in the history of science, history of instrument, philosophy of science and science studies. Can also be used as a textbook in graduate courses on 19th century physics.

  9. Pervasive developmental disorder in the children of immigrant parents: comparison of different assessment instruments

    Directory of Open Access Journals (Sweden)

    Milena Pereira Ponde

    2013-11-01

    Full Text Available The objective of this study was to describe how the Childhood Autism Rating Scale (CARS behaves in relation to the Autism Diagnostic Observation Schedule (ADOS and to clinical diagnosis based on the criteria defined in the Diagnostic and Statistical Manual of Mental Disorders, 4 th Edition (DSM-IV for children of immigrant parents. Forty-nine children of parents who had immigrated to Canada were evaluated. In this sample, the ADOS and the DSM-IV showed complete agreement. Using the standard cut-off point of 30, the CARS showed high specificity and poor sensitivity. The study proposes a cut-off point for the CARS that would include pervasive developmental disorder – not otherwise specified (PDD-NOS. Reducing the cut-off point to 20/21 increased the specificity of the instrument for this group of children without significantly reducing its sensitivity.

  10. Measurement Properties of Instruments for Measuring of Lymphedema: Systematic Review.

    Science.gov (United States)

    Hidding, Janine T; Viehoff, Peter B; Beurskens, Carien H G; van Laarhoven, Hanneke W M; Nijhuis-van der Sanden, Maria W G; van der Wees, Philip J

    2016-12-01

    Lymphedema is a common complication of cancer treatment, resulting in swelling and subjective symptoms. Reliable and valid measurement of this side effect of medical treatment is important. The purpose of this study was to provide best evidence regarding which measurement instruments are most appropriate in measuring lymphedema in its different stages. The PubMed and Web of Science databases were used, and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. Clinical studies on measurement instruments assessing lymphedema were reviewed using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) scoring instrument for quality assessment. Data on reliability, concurrent validity, convergent validity, sensitivity, specificity, applicability, and costs were extracted. Pooled data showed good intrarater intraclass correlation coefficients (ICCs) (.89) for bioimpedance spectroscopy (BIS) in the lower extremities and high intrarater and interrater ICCs for water volumetry, tape measurement, and perometry (.98-.99) in the upper extremities. In the upper extremities, the standard error of measurement was 3.6% (σ=0.7%) for water volumetry, 5.6% (σ=2.1%) for perometry, and 6.6% (σ=2.6%) for tape measurement. Sensitivity of tape measurement in the upper extremities, using different cutoff points, varied from 0.73 to 0.90, and specificity values varied from 0.72 to 0.78. No uniform definition of lymphedema was available, and a gold standard as a reference test was lacking. Items concerning risk of bias were study design, patient selection, description of lymphedema, blinding of test outcomes, and number of included participants. Measurement instruments with evidence for good reliability and validity were BIS, water volumetry, tape measurement, and perometry, where BIS can detect alterations in extracellular fluid in stage 1 lymphedema and the other measurement instruments can detect alterations in volume

  11. Planck 2013 results. II. The Low Frequency Instrument data processing

    DEFF Research Database (Denmark)

    Aghanim, N.; Armitage-Caplan, C.; Arnaud, M.

    2013-01-01

    We describe the data processing pipeline of the Planck Low Frequency Instrument (LFI) data processing centre (DPC) to create and characterize full-sky maps based on the first 15.5 months of operations at 30, 44, and 70 GHz. In particular, we discuss the various steps involved in reducing the data......) is employed to combine radiometric data and pointing information into sky maps, minimizing the variance of correlated noise. Noise covariance matrices, required to compute statistical uncertainties on LFI and Planck products, are also produced. Main beams are estimated down to the approximate to-20 dB level...

  12. Instrument for 3D characterization of autostereoscopic displays

    Science.gov (United States)

    Prévoteau, J.; Chalençon-Piotin, S.; Debons, D.; Lucas, L.; Remion, Y.

    2011-03-01

    We now have numerous autostereoscopic displays, and it is mandatory to characterize them because it will allow to optimize their performances and to make efficient comparison between them. Therefore we need standards so we have to be able to quantify the quality of the viewer's perception. The purpose of the present paper is twofold; we first present a new instrument of characterization of the 3D perception on a given autostereoscopic display; then we propose a new way to realize an experimental protocol allowing to get a full characterization. This instrument will allow us to compare efficiently the different autostereoscopic displays but it will also validate practically the adequacy between the shooting and rendering geometries. In this aim, we are going to match a perceived scene with the virtual scene. It is hardly possible to determine the scene perceived by a viewer placed in front of an autostereoscopic display. Indeed if it may be executable on the pop-out, it is impossible on the depth effect because the depth of the virtual scene is set behind the screen. Therefore, we will have to use an optical illusion based on the deflection of light by a mirror to know the position which the viewer perceives some points of the virtual scene on an autostereoscopic display.

  13. Advanced optical instruments technology

    Science.gov (United States)

    Shao, Mike; Chrisp, Michael; Cheng, Li-Jen; Eng, Sverre; Glavich, Thomas; Goad, Larry; Jones, Bill; Kaarat, Philip; Nein, Max; Robinson, William

    1992-08-01

    The science objectives for proposed NASA missions for the next decades push the state of the art in sensitivity and spatial resolution over a wide range of wavelengths, including the x-ray to the submillimeter. While some of the proposed missions are larger and more sensitive versions of familiar concepts, such as the next generation space telescope, others use concepts, common on the Earth, but new to space, such as optical interferometry, in order to provide spatial resolutions impossible with other concepts. However, despite their architecture, the performance of all of the proposed missions depends critically on the back-end instruments that process the collected energy to produce scientifically interesting outputs. The Advanced Optical Instruments Technology panel was chartered with defining technology development plans that would best improve optical instrument performance for future astrophysics missions. At this workshop the optical instrument was defined as the set of optical components that reimage the light from the telescope onto the detectors to provide information about the spatial, spectral, and polarization properties of the light. This definition was used to distinguish the optical instrument technology issues from those associated with the telescope, which were covered by a separate panel. The panel identified several areas for optical component technology development: diffraction gratings; tunable filters; interferometric beam combiners; optical materials; and fiber optics. The panel also determined that stray light suppression instruments, such as coronagraphs and nulling interferometers, were in need of general development to support future astrophysics needs.

  14. An Investigation of the Relation Between Contact Thermometry and Dew-Point Temperature Realization

    Science.gov (United States)

    Benyon, R.; Böse, N.; Mitter, H.; Mutter, D.; Vicente, T.

    2012-09-01

    Precision optical dew-point hygrometers are the most commonly used transfer standards for the comparison of dew-point temperature realizations at National Metrology Institutes (NMIs) and for disseminating traceability to calibration laboratories. These instruments have been shown to be highly reproducible when properly used. In order to obtain the best performance, the resistance of the platinum resistance thermometer (PRT) embedded in the mirror is usually measured with an external, traceable resistance bridge or digital multimeter. The relation between the conventional calibration of miniature PRTs, prior to their assembly in the mirrors of state-of-the-art optical dew-point hygrometers and their subsequent calibration as dew-point temperature measurement devices, has been investigated. Standard humidity generators of three NMIs were used to calibrate hygrometers of different designs, covering the dew-point temperature range from -75 °C to + 95 °C. The results span more than a decade, during which time successive improvements and modifications were implemented by the manufacturer. The findings are presented and discussed in the context of enabling the optimum use of these transfer standards and as a basis for determining contributions to the uncertainty in their calibration.

  15. EVA: laparoscopic instrument tracking based on Endoscopic Video Analysis for psychomotor skills assessment.

    Science.gov (United States)

    Oropesa, Ignacio; Sánchez-González, Patricia; Chmarra, Magdalena K; Lamata, Pablo; Fernández, Alvaro; Sánchez-Margallo, Juan A; Jansen, Frank Willem; Dankelman, Jenny; Sánchez-Margallo, Francisco M; Gómez, Enrique J

    2013-03-01

    The EVA (Endoscopic Video Analysis) tracking system is a new system for extracting motions of laparoscopic instruments based on nonobtrusive video tracking. The feasibility of using EVA in laparoscopic settings has been tested in a box trainer setup. EVA makes use of an algorithm that employs information of the laparoscopic instrument's shaft edges in the image, the instrument's insertion point, and the camera's optical center to track the three-dimensional position of the instrument tip. A validation study of EVA comprised a comparison of the measurements achieved with EVA and the TrEndo tracking system. To this end, 42 participants (16 novices, 22 residents, and 4 experts) were asked to perform a peg transfer task in a box trainer. Ten motion-based metrics were used to assess their performance. Construct validation of the EVA has been obtained for seven motion-based metrics. Concurrent validation revealed that there is a strong correlation between the results obtained by EVA and the TrEndo for metrics, such as path length (ρ = 0.97), average speed (ρ = 0.94), or economy of volume (ρ = 0.85), proving the viability of EVA. EVA has been successfully validated in a box trainer setup, showing the potential of endoscopic video analysis to assess laparoscopic psychomotor skills. The results encourage further implementation of video tracking in training setups and image-guided surgery.

  16. Measurements of Gun Tube Motion and Muzzle Pointing Error of Main Battle Tanks

    Directory of Open Access Journals (Sweden)

    Peter L. McCall

    2001-01-01

    Full Text Available Beginning in 1990, the US Army Aberdeen Test Center (ATC began testing a prototype cannon mounted in a non-armored turret fitted to an M1A1 Abrams tank chassis. The cannon design incorporated a longer gun tube as a means to increase projectile velocity. A significant increase in projectile impact dispersion was measured early in the test program. Through investigative efforts, the cause of the error was linked to the increased dynamic bending or flexure of the longer tube observed while the vehicle was moving. Research and investigative work was conducted through a collaborative effort with the US Army Research Laboratory, Benet Laboratory, Project Manager – Tank Main Armament Systems, US Army Research and Engineering Center, and Cadillac Gage Textron Inc. New test methods, instrumentation, data analysis procedures, and stabilization control design resulted through this series of investigations into the dynamic tube flexure error source. Through this joint research, improvements in tank fire control design have been developed to improve delivery accuracy. This paper discusses the instrumentation implemented, methods applied, and analysis procedures used to characterize the tube flexure during dynamic tests of a main battle tank and the relationship between gun pointing error and muzzle pointing error.

  17. Mass media image of selected instruments of economic develepment

    Directory of Open Access Journals (Sweden)

    Kruliš Ladislav

    2016-07-01

    Full Text Available The goal of this paper is twofold. Firstly, two instruments of economic development – investment incentives and cluster initiatives – were compared according to the frequency of their occurrence in selected mass media sources in the Czech Republic in the periods 2004-2005 and 2011-2012. Secondly, the mass media image of these two instruments of economic development was evaluated with respect to the frames deductively constructed from literature review. The findings pointed out a higher occurrence of the mass media articles/news dealing with investment incentives. These articles/news were, additionally, more controversial and covered a wider spectrum of frames. Politicians were a relatively more frequent type of actors who created the media message from the articles/news. On the contrary, the mass media articles/news concerning cluster initiatives typically created the frame of positive effects of clusters. The messages were told either by economic experts or by public authority representatives who were closely connected with cluster initiatives. Spatial origin of these messages was rather limited. The definitional vagueness, intangible and uncontroversial nature of cluster initiatives restrained their media appeal.

  18. PRECISION POINTING OF IBEX-Lo OBSERVATIONS

    International Nuclear Information System (INIS)

    Hłond, M.; Bzowski, M.; Möbius, E.; Kucharek, H.; Heirtzler, D.; Schwadron, N. A.; Neill, M. E. O'; Clark, G.; Crew, G. B.; Fuselier, S.; McComas, D. J.

    2012-01-01

    Post-launch boresight of the IBEX-Lo instrument on board the Interstellar Boundary Explorer (IBEX) is determined based on IBEX-Lo Star Sensor observations. Accurate information on the boresight of the neutral gas camera is essential for precise determination of interstellar gas flow parameters. Utilizing spin-phase information from the spacecraft attitude control system (ACS), positions of stars observed by the Star Sensor during two years of IBEX measurements were analyzed and compared with positions obtained from a star catalog. No statistically significant differences were observed beyond those expected from the pre-launch uncertainty in the Star Sensor mounting. Based on the star observations and their positions in the spacecraft reference system, pointing of the IBEX satellite spin axis was determined and compared with the pointing obtained from the ACS. Again, no statistically significant deviations were observed. We conclude that no systematic correction for boresight geometry is needed in the analysis of IBEX-Lo observations to determine neutral interstellar gas flow properties. A stack-up of uncertainties in attitude knowledge shows that the instantaneous IBEX-Lo pointing is determined to within ∼0. 0 1 in both spin angle and elevation using either the Star Sensor or the ACS. Further, the Star Sensor can be used to independently determine the spacecraft spin axis. Thus, Star Sensor data can be used reliably to correct the spin phase when the Star Tracker (used by the ACS) is disabled by bright objects in its field of view. The Star Sensor can also determine the spin axis during most orbits and thus provides redundancy for the Star Tracker.

  19. Smart instrumentation development at Los Alamos

    International Nuclear Information System (INIS)

    Erkkila, B.

    1984-01-01

    For several years Los Alamos has incorporated microprocessors into instruments to expand the capability of portable survey type equipment. Beginning with portable pulse height analyzers, the developments have expanded to small dedicated instruments which handle the measurement and interpretation of various radiation fields. So far, instruments to measure gamma rays, neutrons, and beta particles have been produced. The computer capability built into these instruments provides significant computational power into the instruments. Capability unheard of a few years ago in small portable instruments is routine today. Large computer-based laboratory measurement systems which required much space and electrical power can now be incorporated in a portable hand-held instrument. The microprocessor developments at Los Alamos are now restricted to radiation monitoring equipment but can be expanded to chemical and biological applications as well. Applications for radiation monitoring equipment and others are discussed

  20. Instruments

    International Nuclear Information System (INIS)

    Buehrer, W.

    1996-01-01

    The present paper mediates a basic knowledge of the most commonly used experimental techniques. We discuss the principles and concepts necessary to understand what one is doing if one performs an experiment on a certain instrument. (author) 29 figs., 1 tab., refs

  1. Keyboard Instruments and Instrumentalists in Manila (1581-1798

    Directory of Open Access Journals (Sweden)

    Irving, David

    2005-12-01

    Full Text Available While countless keyboard instruments were made in the Philippine Islands or imported there during the Spanish colonial period (1565-1898, most of those which survive date from the nineteenth century. It should be noted, however, that keyboard music flourished in the Philippines from the early years of Spanish presence. Instruments began to arrive in the late-sixteenth century, and over the following two centuries, numerous organs were manufactured in mission schools throughout the archipelago. The final years of the eighteenth century were a high point in colonial instrument-building, moreover, with the arrival of the Recollect missionary and instrument-builder Diego Cera de la Virgen del Carmen in 1792 and the establishment of his workshop. While some evidence remains fragmentary, there is still a great deal of archival information to be pieced together, and a comprehensive survey of keyboard instruments and instrumentalists present in colonial Manila remains to be undertaken. This article attempts to address this lacuna in part, covering the period between 1581 and 1798.

    Aunque muchos instrumentos de teclado fueron fabricados en las Filipinas o importados por aquellas islas durante el período colonial español (1565-1878, la mayor parte de los que aún existen son del siglo XIX. Debe tenerse en cuenta, sin embargo, que la música para teclado tuvo un auge importante en Filipinas desde los inicios mismos de la presencia española. Empezaron a llegar diversos instrumentos hacia finales del siglo XVI, y a lo largo de los dos siglos siguientes se construyeron varios órganos en las escuelas de las misiones presentes en el archipiélago. Al final del siglo XVIII muchos instrumentos fueron construidos en las colonias, sobre todo con la llegada del misionero y constructor de instrumentos, Diego Cera de la Virgen en el año 1792, y el establecimiento de su taller. Aunque sólo disponemos de una información incompleta, aún existe mucha

  2. Origins, transformations and key foci in instrumental genesis

    DEFF Research Database (Denmark)

    Tamborg, Andreas Lindenskov

    This paper investigates the origins of the instrumental genesis and instrumental orchestrations frameworks. This is done by reviewing instrumented activity situations, instrumental genesis, and instrumental orchestrations with the purpose of identifying their epistemological assumptions, what the...... and instrumental orchestrations have potential shortcomings since the technologies that currently exist in school contexts are rather different from the technologies instrumental genesis was originally developed to study.......This paper investigates the origins of the instrumental genesis and instrumental orchestrations frameworks. This is done by reviewing instrumented activity situations, instrumental genesis, and instrumental orchestrations with the purpose of identifying their epistemological assumptions, what...

  3. Instrument uncertainty predictions

    International Nuclear Information System (INIS)

    Coutts, D.A.

    1991-07-01

    The accuracy of measurements and correlations should normally be provided for most experimental activities. The uncertainty is a measure of the accuracy of a stated value or equation. The uncertainty term reflects a combination of instrument errors, modeling limitations, and phenomena understanding deficiencies. This report provides several methodologies to estimate an instrument's uncertainty when used in experimental work. Methods are shown to predict both the pretest and post-test uncertainty

  4. Aspects of progress in neutron instrumentation

    International Nuclear Information System (INIS)

    Carlile, C.J.

    1999-01-01

    The capability of neutron instrumentation in coming years will depend upon many factors, the main ones being the neutron source the instrument is sited on, the quality of the instrument itself, the quality of the support provided and the protocol for instrument operation. All of these factors must be optimised and improved upon to ensure consistently high quality scientific exploitation of an instrument. Examples of progress in each of these fields are given and a subjective view of possible future trends are hazarded. (author)

  5. Advanced neutron instrumentation at FRM-II

    International Nuclear Information System (INIS)

    Petry, Winfried

    2003-01-01

    The construction of the new German high flux neutron source FRM-II is finished and FRM-II is waiting for its licence to start nuclear operation. With the beginning of the routine operation 22 instruments will be in action, including 5 irradiation facilities and 17 beam tube instruments, most of them use neutron scattering techniques. Additional instruments are under construction. Some of these instruments are unique, others are expected to be the best of their kind, all instruments are based on innovative techniques. (author)

  6. Instrumentation requirements for the ESF thermomechanical experiments

    International Nuclear Information System (INIS)

    Pott, J.; Brechtel, C.E.

    1992-01-01

    In situ thermomechanical experiments are planned as part of the Yucca Mountain Site Characterization Project that require instruments to measure stress and displacement at temperatures that exceed the typical specifications of existing geotechnical instruments. A high degree of instrument reliability will also be required to satisfy the objectives of the experiments, therefore a study was undertaken to identify areas where improvement in instrument performance was required. A preliminary list of instruments required for the experiments was developed, based on existing test planning and analysis. Projected temperature requirements were compared to specifications of existing instruments to identify instrumentation development needs. Different instrument technologies, not currently employed in geotechnical instrumentation, were reviewed to identify potential improvements of existing designs for the high temperature environment. Technologies with strong potentials to improve instrument performance with relatively high reliability include graphite fiber composite materials, fiber optics, and video imagery

  7. Rio de Janeiro: Instrumentation school

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Students from Latin America were able to get hands-on experience in state-of-the-art physics instrumentation in this year's School on Instrumentation for High Energy Physics organized by the active Instrumentation Panel of ICFA (the International Committee for Future Accelerators) at the Centro Brasileiro de Pesquicas Fisicas (CBPF), Rio de Janeiro, in July

  8. Ambulatory Feedback System

    Science.gov (United States)

    Finger, Herbert; Weeks, Bill

    1985-01-01

    This presentation discusses instrumentation that will be used for a specific event, which we hope will carry on to future events within the Space Shuttle program. The experiment is the Autogenic Feedback Training Experiment (AFTE) scheduled for Spacelab 3, currently scheduled to be launched in November, 1984. The objectives of the AFTE are to determine the effectiveness of autogenic feedback in preventing or reducing space adaptation syndrome (SAS), to monitor and record in-flight data from the crew, to determine if prediction criteria for SAS can be established, and, finally, to develop an ambulatory instrument package to mount the crew throughout the mission. The purpose of the Ambulatory Feedback System (AFS) is to record the responses of the subject during a provocative event in space and provide a real-time feedback display to reinforce the training.

  9. Mapping the infrared background radiation from the Shuttle

    Science.gov (United States)

    Koch, D.; Fazio, G. G.; Traub, W. A.; Urban, E. W.; Katz, L.; Rieke, G. H.; Gautier, T. N.; Hoffmann, W. F.; Low, F. J.; Poteet, W.

    1981-01-01

    The Spacelab-2 Small Helium-Cooled Infrared Telescope will be used to map extended astronomical sources of low surface brightness emission, to measure the Shuttle induced environment and to develop techniques for managing large volumes of superfluid helium in space. The instrument is an f/4 15.2-cm Herschelian telescope with ten photoconductor detectors in the focal plane. This paper describes the hardware and software aspects of the instrument with emphasis on mission operations. In particular, a description is given of the observing plan formulated to meet the scientific and engineering objectives, the scan drive system, the precautions in design and operation necessary to prevent the sun, moon, and earth from adversely affecting the observations, the implications of thruster firings, and the on-board experiment computer application software to control the scanning of the telescope and support on-board displays.

  10. Screening for Internet Addiction: An Empirical Study on Cut-off Points for the Chen Internet Addiction Scale

    Directory of Open Access Journals (Sweden)

    Chih-Hung Ko

    2005-12-01

    Full Text Available The aim of this study was to establish the optimal cut-off points of the Chen Internet Addiction Scale (CIAS, to screen for and diagnose Internet addiction among adolescents in the community by using the well- established diagnostic criteria of Internet addiction. This survey of 454 adolescents used screening (57/58 and diagnostic (63/64 cut-off points of the CIAS, a self-reported instrument, based on the results of systematic diagnostic interviews by psychiatrists. The area under the curve of the receiver operating characteristic curve revealed that CIAS has good diagnostic accuracy (89.6%. The screening cut-off point had high sensitivity (85.6% and the diagnostic cut-off point had the highest diagnostic accuracy, classifying 87.6% of participants correctly. Accordingly, the screening point of the CIAS could provide a screening function in two-stage diagnosis, and the diagnostic point could serve as a diagnostic criterion in one-stage massive epidemiologic research.

  11. Innovative instrumentation

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    At this year's particle physics conference at Brighton, a parallel session was given over to instrumentation and detector development. While this work is vital to the health of research and its continued progress, its share of prime international conference time is limited. Instrumentation can be innovative three times — first when a new idea is outlined, secondly when it is shown to be feasible, and finally when it becomes productive in a real experiment, amassing useful data rather than operational experience. Hyams' examples showed that it can take a long time for a new idea to filter through these successive stages, if it ever makes it at all

  12. Innovative instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1983-11-15

    At this year's particle physics conference at Brighton, a parallel session was given over to instrumentation and detector development. While this work is vital to the health of research and its continued progress, its share of prime international conference time is limited. Instrumentation can be innovative three times — first when a new idea is outlined, secondly when it is shown to be feasible, and finally when it becomes productive in a real experiment, amassing useful data rather than operational experience. Hyams' examples showed that it can take a long time for a new idea to filter through these successive stages, if it ever makes it at all.

  13. Instrumental aspects

    Directory of Open Access Journals (Sweden)

    Qureshi Navid

    2017-01-01

    Full Text Available Every neutron scattering experiment requires the choice of a suited neutron diffractometer (or spectrometer in the case of inelastic scattering with its optimal configuration in order to accomplish the experimental tasks in the most successful way. Most generally, the compromise between the incident neutron flux and the instrumental resolution has to be considered, which is depending on a number of optical devices which are positioned in the neutron beam path. In this chapter the basic instrumental principles of neutron diffraction will be explained. Examples of different types of experiments and their respective expectable results will be shown. Furthermore, the production and use of polarized neutrons will be stressed.

  14. The SLICE, CHESS, and SISTINE Ultraviolet Spectrographs: Rocket-Borne Instrumentation Supporting Future Astrophysics Missions

    Science.gov (United States)

    France, Kevin; Hoadley, Keri; Fleming, Brian T.; Kane, Robert; Nell, Nicholas; Beasley, Matthew; Green, James C.

    2016-03-01

    NASA’s suborbital program provides an opportunity to conduct unique science experiments above Earth’s atmosphere and is a pipeline for the technology and personnel essential to future space astrophysics, heliophysics, and atmospheric science missions. In this paper, we describe three astronomy payloads developed (or in development) by the Ultraviolet Rocket Group at the University of Colorado. These far-ultraviolet (UV) (100-160nm) spectrographic instruments are used to study a range of scientific topics, from gas in the interstellar medium (accessing diagnostics of material spanning five orders of magnitude in temperature in a single observation) to the energetic radiation environment of nearby exoplanetary systems. The three instruments, Suborbital Local Interstellar Cloud Experiment (SLICE), Colorado High-resolution Echelle Stellar Spectrograph (CHESS), and Suborbital Imaging Spectrograph for Transition region Irradiance from Nearby Exoplanet host stars (SISTINE) form a progression of instrument designs and component-level technology maturation. SLICE is a pathfinder instrument for the development of new data handling, storage, and telemetry techniques. CHESS and SISTINE are testbeds for technology and instrument design enabling high-resolution (R>105) point source spectroscopy and high throughput imaging spectroscopy, respectively, in support of future Explorer, Probe, and Flagship-class missions. The CHESS and SISTINE payloads support the development and flight testing of large-format photon-counting detectors and advanced optical coatings: NASA’s top two technology priorities for enabling a future flagship observatory (e.g. the LUVOIR Surveyor concept) that offers factors of ˜50-100 gain in UV spectroscopy capability over the Hubble Space Telescope. We present the design, component level laboratory characterization, and flight results for these instruments.

  15. High-Level Disinfection of Otorhinolaryngology Clinical Instruments: An Evaluation of the Efficacy and Cost-effectiveness of Instrument Storage.

    Science.gov (United States)

    Yalamanchi, Pratyusha; Yu, Jason; Chandler, Laura; Mirza, Natasha

    2018-01-01

    Objectives Despite increasing interest in individual instrument storage, risk of bacterial cross-contamination of otorhinolaryngology clinic instruments has not been assessed. This study is the first to determine the clinical efficacy and cost-effectiveness of standard high-level disinfection and clinic instrument storage. Methods To assess for cross-contamination, surveillance cultures of otorhinolaryngology clinic instruments subject to standard high-level disinfection and storage were obtained at the start and end of the outpatient clinical workday. Rate of microorganism recovery was compared with cultures of instruments stored in individual peel packs and control cultures of contaminated instruments. Based on historical clinic data, the direct allocation method of cost accounting was used to determine aggregate raw material cost and additional labor hours required to process and restock peel-packed instruments. Results Among 150 cultures of standard high-level disinfected and co-located clinic instruments, 3 positive bacterial cultures occurred; 100% of control cultures were positive for bacterial species ( P cost of individual semicritical instrument storage at $97,852.50 per year. Discussion With in vitro inoculation of >200 otorhinolaryngology clinic instruments, this study demonstrates that standard high-level disinfection and storage are equally efficacious to more time-consuming and expensive individual instrument storage protocols, such as peel packing, with regard to bacterial contamination. Implications for Practice Standard high-level disinfection and storage are equally effective to labor-intensive and costly individual instrument storage protocols.

  16. Technological considerations in emergency instrument preparedness

    International Nuclear Information System (INIS)

    Selby, J.M.

    1975-01-01

    The types of emergency instrumentation systems necessary to characterize the severity and extent of radiation accidents and to aid in the protection of operating personnel and personnel living near the plant are discussed. These include instruments for direct measurement of the airborne radioactive material within the facility, fixed instrumentation for ambient dose rate monitoring or area monitoring, and portable instruments for environmental monitoring

  17. NT-proBNP on Cobas h 232 in point-of-care testing

    DEFF Research Database (Denmark)

    Gils, Charlotte; Ramanathan, R.; Breindahl, T.

    2015-01-01

    Background. NT-proBNP may be useful for ruling out heart failure in primary health care. In this study we examined the analytical quality of NT-proBNP in primary health care on the Cobas h 232 point-of-care instrument compared with measurements performed in a hospital laboratory. Materials...... and methods. Blood samples requested for NT-proBNP were collected in primary health care (n = 95) and in a hospital laboratory (n = 107). NT-proBNP was measured on-site on Cobas h 232 instruments both in primary health care centres and at the hospital laboratory and all samples were also analyzed...... with a comparison method at the hospital. Precision, trueness, accuracy, and lot-variation were determined at different concentration levels and evaluated according to acceptance criteria. Furthermore user-friendliness was assessed by questionnaires. Results. For Cobas h 232 repeatability CV was 8...

  18. The latest radiation instrument

    International Nuclear Information System (INIS)

    Kang, Se Sik; Gwon, Dal Gwan; Kim, Gyeong Geum

    2008-08-01

    This book deals with the latest radiation instrument, which is comprised of eight chapters. It explains X rays instrument for medial treatment, X-ray tube instrument and permissible burden with its history, structure and characteristic high voltage apparatus with high voltage rectifier circuit, X-ray control apparatus for medical treatment, X-ray image equipment X-ray television apparatus and CCD 205, X-ray apparatus of install and types, Digital X-ray apparatus with CR 261 and DR 269, performance management on X-ray for medical treatment with its history, necessity and management in the radiation field.

  19. Robust Instrumentation[Water treatment for power plant]; Robust Instrumentering

    Energy Technology Data Exchange (ETDEWEB)

    Wik, Anders [Vattenfall Utveckling AB, Stockholm (Sweden)

    2003-08-01

    Cementa Slite Power Station is a heat recovery steam generator (HRSG) with moderate steam data; 3.0 MPa and 420 deg C. The heat is recovered from Cementa, a cement industry, without any usage of auxiliary fuel. The Power station commenced operation in 2001. The layout of the plant is unusual, there are no similar in Sweden and very few world-wide, so the operational experiences are limited. In connection with the commissioning of the power plant a R and D project was identified with the objective to minimise the manpower needed for chemistry management of the plant. The lean chemistry management is based on robust instrumentation and chemical-free water treatment plant. The concept with robust instrumentation consists of the following components; choice of on-line instrumentation with a minimum of O and M and a chemical-free water treatment. The parameters are specific conductivity, cation conductivity, oxygen and pH. In addition to that, two fairly new on-line instruments were included; corrosion monitors and differential pH calculated from specific and cation conductivity. The chemical-free water treatment plant consists of softening, reverse osmosis and electro-deionisation. The operational experience shows that the cycle chemistry is not within the guidelines due to major problems with the operation of the power plant. These problems have made it impossible to reach steady state and thereby not viable to fully verify and validate the concept with robust instrumentation. From readings on the panel of the online analysers some conclusions may be drawn, e.g. the differential pH measurements have fulfilled the expectations. The other on-line analysers have been working satisfactorily apart from contamination with turbine oil, which has been noticed at least twice. The corrosion monitors seem to be working but the lack of trend curves from the mainframe computer system makes it hard to draw any clear conclusions. The chemical-free water treatment has met all

  20. Three Canted Radiator Panels to Provide Adequate Cooling for Instruments on Slewing Spacecraft in LEO

    Science.gov (United States)

    Choi, Michael K.

    2012-01-01

    Certain free-flying spacecraft in low Earth orbit (LEO) or payloads on the International Space Station (ISS) are required to slew to point the telescopes at targets. Instrument detectors and electronics require cooling. Traditionally a planar thermal radiator is used. The temperature of such a radiator varies significantly when the spacecraft slews because its view factors to space vary significantly. Also for payloads on the ISS, solar impingement on the radiator is possible. These thermal adversities could lead to inadequate cooling for the instrument. This paper presents a novel thermal design concept that utilizes three canted radiator panels to mitigate this problem. It increases the overall radiator view factor to cold space and reduces the overall solar or albedo flux absorbed per unit area of the radiator.